NASA Astrophysics Data System (ADS)
Wang, Li; Li, Chuanghong
2018-02-01
As a sustainable form of ecological structure, green building is widespread concerned and advocated in society increasingly nowadays. In the survey and design phase of preliminary project construction, carrying out the evaluation and selection of green building design scheme, which is in accordance with the scientific and reasonable evaluation index system, can improve the ecological benefits of green building projects largely and effectively. Based on the new Green Building Evaluation Standard which came into effect on January 1, 2015, the evaluation index system of green building design scheme is constructed taking into account the evaluation contents related to the green building design scheme. We organized experts who are experienced in construction scheme optimization to mark and determine the weight of each evaluation index through the AHP method. The correlation degree was calculated between each evaluation scheme and ideal scheme by using multilevel gray relational analysis model and then the optimal scheme was determined. The feasibility and practicability of the evaluation method are verified by introducing examples.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurnik, Charles W.; Keates, Steven
This protocol is intended to describe the recommended method when evaluating the whole-building performance of new construction projects in the commercial sector. The protocol focuses on energy conservation measures (ECMs) or packages of measures where evaluators can analyze impacts using building simulation. These ECMs typically require the use of calibrated building simulations under Option D of the International Performance Measurement and Verification Protocol (IPMVP).
Developing Methodologies for Evaluating the Earthquake Safety of Existing Buildings.
ERIC Educational Resources Information Center
Bresler, B.; And Others
This report contains four papers written during an investigation of methods for evaluating the safety of existing school buildings under Research Applied to National Needs (RANN) grants. In "Evaluation of Earthquake Safety of Existing Buildings," by B. Bresler, preliminary ideas on the evaluation of the earthquake safety of existing…
LANL seismic screening method for existing buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dickson, S.L.; Feller, K.C.; Fritz de la Orta, G.O.
1997-01-01
The purpose of the Los Alamos National Laboratory (LANL) Seismic Screening Method is to provide a comprehensive, rational, and inexpensive method for evaluating the relative seismic integrity of a large building inventory using substantial life-safety as the minimum goal. The substantial life-safety goal is deemed to be satisfied if the extent of structural damage or nonstructural component damage does not pose a significant risk to human life. The screening is limited to Performance Category (PC) -0, -1, and -2 buildings and structures. Because of their higher performance objectives, PC-3 and PC-4 buildings automatically fail the LANL Seismic Screening Method andmore » will be subject to a more detailed seismic analysis. The Laboratory has also designated that PC-0, PC-1, and PC-2 unreinforced masonry bearing wall and masonry infill shear wall buildings fail the LANL Seismic Screening Method because of their historically poor seismic performance or complex behavior. These building types are also recommended for a more detailed seismic analysis. The results of the LANL Seismic Screening Method are expressed in terms of separate scores for potential configuration or physical hazards (Phase One) and calculated capacity/demand ratios (Phase Two). This two-phase method allows the user to quickly identify buildings that have adequate seismic characteristics and structural capacity and screen them out from further evaluation. The resulting scores also provide a ranking of those buildings found to be inadequate. Thus, buildings not passing the screening can be rationally prioritized for further evaluation. For the purpose of complying with Executive Order 12941, the buildings failing the LANL Seismic Screening Method are deemed to have seismic deficiencies, and cost estimates for mitigation must be prepared. Mitigation techniques and cost-estimate guidelines are not included in the LANL Seismic Screening Method.« less
Post Occupancy Evaluation of Educational Buildings and Equipment.
ERIC Educational Resources Information Center
Watson, Chris
1997-01-01
Details the post occupancy evaluation (POE) process for public buildings. POEs are used to improve design and optimize educational building and equipment use. The evaluation participants, the method used, the results and recommendations, model schools, and classroom alterations using POE are described. (9 references.) (RE)
Xie, Qiuju; Ni, Ji-Qin; Su, Zhongbin
2017-10-15
In confined swine buildings, temperature, humidity, and air quality are all important for animal health and productivity. However, the current swine building environmental control is only based on temperature; and evaluation and control methods based on multiple environmental factors are needed. In this paper, fuzzy comprehensive evaluation (FCE) theory was adopted for multi-factor assessment of environmental quality in two commercial swine buildings using real measurement data. An assessment index system and membership functions were established; and predetermined weights were given using analytic hierarchy process (AHP) combined with knowledge of experts. The results show that multi-factors such as temperature, humidity, and concentrations of ammonia (NH 3 ), carbon dioxide (CO 2 ), and hydrogen sulfide (H 2 S) can be successfully integrated in FCE for swine building environment assessment. The FCE method has a high correlation coefficient of 0.737 compared with the method of single-factor evaluation (SFE). The FCE method can significantly increase the sensitivity and perform an effective and integrative assessment. It can be used as part of environmental controlling and warning systems for swine building environment management to improve swine production and welfare. Copyright © 2017 Elsevier B.V. All rights reserved.
Status Report on the Evaluation of the Alternative Asbestos Control Method – A Comparison to the NESHAP Method of Demolition of Asbestos Containing Buildings. This abstract and presentation are based, at least in part, on preliminary data and conclusions. The Alternative Asbestos...
Seismic evaluation of vulnerability for SAMA educational buildings in Tehran
DOE Office of Scientific and Technical Information (OSTI.GOV)
Amini, Omid Nassiri; Amiri, Javad Vaseghi
2008-07-08
Earthquake is a destructive phenomenon that trembles different parts of the earth yearly and causes many destructions. Iran is one of the (high seismicity) quack- prone parts of the world that has received a lot of pecuniary damages and life losses each year, schools are of the most important places to be protected during such crisis.There was no special surveillance on designing and building of school's building in Tehran till the late 70's, and as Tehran is on faults, instability of such buildings may cause irrecoverable pecuniary damages and especially life losses, therefore preventing this phenomenon is in an urgentmore » need.For this purpose, some of the schools built during 67-78 mostly with Steel braced frame structures have been selected, first, by evaluating the selected Samples, gathering information and Visual Survey, the prepared questionnaires were filled out. With the use of ARIA and SABA (Venezuela) Methods, new modified combined method for qualified evaluations was found and used.Then, for quantified evaluation, with the use of computer 3D models and nonlinear statically analysis methods, a number of selected buildings of qualified evaluation, were reevaluated and finally with nonlinear dynamic analysis method the real behavior of structures on the earthquakes is studied.The results of qualified and quantified evaluations were compared and a proper Pattern for seismic evaluation of Educational buildings was presented. Otherwise the results can be a guidance for the person in charge of retrofitting or if necessary rebuilding the schools.« less
Evaluating hospital design from an operations management perspective.
Vos, Leti; Groothuis, Siebren; van Merode, Godefridus G
2007-12-01
This paper describes an evaluation method for the assessment of hospital building design from the viewpoint of operations management to assure that the building design supports the efficient and effective operating of care processes now and in the future. The different steps of the method are illustrated by a case study. In the case study an experimental design is applied to assess the effect of used logistical concepts, patient mix and technologies. The study shows that the evaluation method provides a valuable tool for the assessment of both functionality and the ability to meet future developments in operational control of a building design.
A Robust Gradient Based Method for Building Extraction from LiDAR and Photogrammetric Imagery.
Siddiqui, Fasahat Ullah; Teng, Shyh Wei; Awrangjeb, Mohammad; Lu, Guojun
2016-07-19
Existing automatic building extraction methods are not effective in extracting buildings which are small in size and have transparent roofs. The application of large area threshold prohibits detection of small buildings and the use of ground points in generating the building mask prevents detection of transparent buildings. In addition, the existing methods use numerous parameters to extract buildings in complex environments, e.g., hilly area and high vegetation. However, the empirical tuning of large number of parameters reduces the robustness of building extraction methods. This paper proposes a novel Gradient-based Building Extraction (GBE) method to address these limitations. The proposed method transforms the Light Detection And Ranging (LiDAR) height information into intensity image without interpolation of point heights and then analyses the gradient information in the image. Generally, building roof planes have a constant height change along the slope of a roof plane whereas trees have a random height change. With such an analysis, buildings of a greater range of sizes with a transparent or opaque roof can be extracted. In addition, a local colour matching approach is introduced as a post-processing stage to eliminate trees. This stage of our proposed method does not require any manual setting and all parameters are set automatically from the data. The other post processing stages including variance, point density and shadow elimination are also applied to verify the extracted buildings, where comparatively fewer empirically set parameters are used. The performance of the proposed GBE method is evaluated on two benchmark data sets by using the object and pixel based metrics (completeness, correctness and quality). Our experimental results show the effectiveness of the proposed method in eliminating trees, extracting buildings of all sizes, and extracting buildings with and without transparent roof. When compared with current state-of-the-art building extraction methods, the proposed method outperforms the existing methods in various evaluation metrics.
A Robust Gradient Based Method for Building Extraction from LiDAR and Photogrammetric Imagery
Siddiqui, Fasahat Ullah; Teng, Shyh Wei; Awrangjeb, Mohammad; Lu, Guojun
2016-01-01
Existing automatic building extraction methods are not effective in extracting buildings which are small in size and have transparent roofs. The application of large area threshold prohibits detection of small buildings and the use of ground points in generating the building mask prevents detection of transparent buildings. In addition, the existing methods use numerous parameters to extract buildings in complex environments, e.g., hilly area and high vegetation. However, the empirical tuning of large number of parameters reduces the robustness of building extraction methods. This paper proposes a novel Gradient-based Building Extraction (GBE) method to address these limitations. The proposed method transforms the Light Detection And Ranging (LiDAR) height information into intensity image without interpolation of point heights and then analyses the gradient information in the image. Generally, building roof planes have a constant height change along the slope of a roof plane whereas trees have a random height change. With such an analysis, buildings of a greater range of sizes with a transparent or opaque roof can be extracted. In addition, a local colour matching approach is introduced as a post-processing stage to eliminate trees. This stage of our proposed method does not require any manual setting and all parameters are set automatically from the data. The other post processing stages including variance, point density and shadow elimination are also applied to verify the extracted buildings, where comparatively fewer empirically set parameters are used. The performance of the proposed GBE method is evaluated on two benchmark data sets by using the object and pixel based metrics (completeness, correctness and quality). Our experimental results show the effectiveness of the proposed method in eliminating trees, extracting buildings of all sizes, and extracting buildings with and without transparent roof. When compared with current state-of-the-art building extraction methods, the proposed method outperforms the existing methods in various evaluation metrics. PMID:27447631
Hanlon, C; Semrau, M; Alem, A; Abayneh, S; Abdulmalik, J; Docrat, S; Evans-Lacko, S; Gureje, O; Jordans, M; Lempp, H; Mugisha, J; Petersen, I; Shidhaye, R; Thornicroft, G
2018-02-01
Efforts to support the scale-up of integrated mental health care in low- and middle-income countries (LMICs) need to focus on building human resource capacity in health system strengthening, as well as in the direct provision of mental health care. In a companion editorial, we describe a range of capacity-building activities that are being implemented by a multi-country research consortium (Emerald: Emerging mental health systems in low- and middle-income countries) for (1) service users and caregivers, (2) service planners and policy-makers and (3) researchers in six LMICs (Ethiopia, India, Nepal, Nigeria, South Africa and Uganda). In this paper, we focus on the methodology being used to evaluate the impact of capacity-building in these three target groups. We first review the evidence base for approaches to evaluation of capacity-building, highlighting the gaps in this area. We then describe the adaptation of best practice for the Emerald capacity-building evaluation. The resulting mixed method evaluation framework was tailored to each target group and to each country context. We identified a need to expand the evidence base on indicators of successful capacity-building across the different target groups. To address this, we developed an evaluation plan to measure the adequacy and usefulness of quantitative capacity-building indicators when compared with qualitative evaluation. We argue that evaluation needs to be an integral part of capacity-building activities and that expertise needs to be built in methods of evaluation. The Emerald evaluation provides a potential model for capacity-building evaluation across key stakeholder groups and promises to extend understanding of useful indicators of success.
PRELIMINARY RESULTS: EVALUATIONS OF THE ALTERNATIVE ASBESTOS CONTROL METHOD FOR BUILDING DEMOLITION
This presentation describes the preliminary results of the evaluations of the alternative asbestos control method for demolishing buildings containing asbestos, and are covered under the regulatory requirements of the Asbestos NESHAP. This abstract and presentation are based, at ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurnik, Charles W.; Agnew, Ken; Goldberg, Mimi
Whole-building retrofits involve the installation of multiple measures. Whole-building retrofit programs take many forms. With a focus on overall building performance, these programs usually begin with an energy audit to identify cost-effective energy efficiency measures for the home. Measures are then installed, either at no cost to the homeowner or partially paid for by rebates and/or financing. The methods described here may also be applied to evaluation of single-measure retrofit programs. Related methods exist for replace-on-failure programs and for new construction, but are not the subject of this chapter.
Assessing nest-building behavior of mice using a 3D depth camera.
Okayama, Tsuyoshi; Goto, Tatsuhiko; Toyoda, Atsushi
2015-08-15
We developed a novel method to evaluate the nest-building behavior of mice using an inexpensive depth camera. The depth camera clearly captured nest-building behavior. Using three-dimensional information from the depth camera, we obtained objective features for assessing nest-building behavior, including "volume," "radius," and "mean height". The "volume" represents the change in volume of the nesting material, a pressed cotton square that a mouse shreds and untangles in order to build its nest. During the nest-building process, the total volume of cotton fragments is increased. The "radius" refers to the radius of the circle enclosing the fragments of cotton. It describes the extent of nesting material dispersion. The "radius" averaged approximately 60mm when a nest was built. The "mean height" represents the change in the mean height of objects. If the nest walls were high, the "mean height" was also high. These features provided us with useful information for assessment of nest-building behavior, similar to conventional methods for the assessment of nest building. However, using the novel method, we found that JF1 mice built nests with higher walls than B6 mice, and B6 mice built nests faster than JF1 mice. Thus, our novel method can evaluate the differences in nest-building behavior that cannot be detected or quantified by conventional methods. In future studies, we will evaluate nest-building behaviors of genetically modified, as well as several inbred, strains of mice, with several nesting materials. Copyright © 2015 Elsevier B.V. All rights reserved.
Bai, Xiao-ping; Zhang, Xi-wei
2013-01-01
Selecting construction schemes of the building engineering project is a complex multiobjective optimization decision process, in which many indexes need to be selected to find the optimum scheme. Aiming at this problem, this paper selects cost, progress, quality, and safety as the four first-order evaluation indexes, uses the quantitative method for the cost index, uses integrated qualitative and quantitative methodologies for progress, quality, and safety indexes, and integrates engineering economics, reliability theories, and information entropy theory to present a new evaluation method for building construction project. Combined with a practical case, this paper also presents detailed computing processes and steps, including selecting all order indexes, establishing the index matrix, computing score values of all order indexes, computing the synthesis score, sorting all selected schemes, and making analysis and decision. Presented method can offer valuable references for risk computing of building construction projects.
Development of new methodologies for evaluating the energy performance of new commercial buildings
NASA Astrophysics Data System (ADS)
Song, Suwon
The concept of Measurement and Verification (M&V) of a new building continues to become more important because efficient design alone is often not sufficient to deliver an efficient building. Simulation models that are calibrated to measured data can be used to evaluate the energy performance of new buildings if they are compared to energy baselines such as similar buildings, energy codes, and design standards. Unfortunately, there is a lack of detailed M&V methods and analysis methods to measure energy savings from new buildings that would have hypothetical energy baselines. Therefore, this study developed and demonstrated several new methodologies for evaluating the energy performance of new commercial buildings using a case-study building in Austin, Texas. First, three new M&V methods were developed to enhance the previous generic M&V framework for new buildings, including: (1) The development of a method to synthesize weather-normalized cooling energy use from a correlation of Motor Control Center (MCC) electricity use when chilled water use is unavailable, (2) The development of an improved method to analyze measured solar transmittance against incidence angle for sample glazing using different solar sensor types, including Eppley PSP and Li-Cor sensors, and (3) The development of an improved method to analyze chiller efficiency and operation at part-load conditions. Second, three new calibration methods were developed and analyzed, including: (1) A new percentile analysis added to the previous signature method for use with a DOE-2 calibration, (2) A new analysis to account for undocumented exhaust air in DOE-2 calibration, and (3) An analysis of the impact of synthesized direct normal solar radiation using the Erbs correlation on DOE-2 simulation. Third, an analysis of the actual energy savings compared to three different energy baselines was performed, including: (1) Energy Use Index (EUI) comparisons with sub-metered data, (2) New comparisons against Standards 90.1-1989 and 90.1-2001, and (3) A new evaluation of the performance of selected Energy Conservation Design Measures (ECDMs). Finally, potential energy savings were also simulated from selected improvements, including: minimum supply air flow, undocumented exhaust air, and daylighting.
BLAST: Building energy simulation in Hong Kong
NASA Astrophysics Data System (ADS)
Fong, Sai-Keung
1999-11-01
The characteristics of energy use in buildings under local weather conditions were studied and evaluated using the energy simulation program BLAST-3.0. The parameters used in the energy simulation for the study and evaluation include the architectural features, different internal building heat load settings and weather data. In this study, mathematical equations and the associated coefficients useful to the industry were established. A technology for estimating energy use in buildings under local weather conditions was developed by using the results of this study. A weather data file of Typical Meteorological Years (TMY) has been compiled for building energy studies by analyzing and evaluating the weather of Hong Kong from the year 1979 to 1988. The weather data file TMY and the example weather years 1980 and 1988 were used by BLAST-3.0 to evaluate and study the energy use in different buildings. BLAST-3.0 was compared with other building energy simulation and approximation methods: Bin method and Degree Days method. Energy use in rectangular compartments of different volumes varying from 4,000 m3 to 40,000 m3 with different aspect ratios were analyzed. The use of energy in buildings with concrete roofs was compared with those with glass roofs at indoor temperature 21°C, 23°C and 25°C. Correlation relationships among building energy, space volume, monthly mean temperature and solar radiation were derived and investigated. The effects of space volume, monthly mean temperature and solar radiation on building energy were evaluated. The coefficients of the mathematical relationships between space volume and energy use in a building were computed and found satisfactory. The calculated coefficients can be used for quick estimation of energy use in buildings under similar situations. To study energy use in buildings, the cooling load per floor area against room volume was investigated. The case of an air-conditioned single compartment with 5 m ceiling height was evaluated. It was found that the supply of cool air to the lower portion of the compartment provided significant performance of space cooling. The mathematical relationships between different shading patterns and different glass window to wall ratios of single compartments were established to provide a guide for easy approximation of energy use under similar conditions. In addition, the Overall Thermal Transfer Values (OTTV) for the compartments were studied. The monthly and annual energy use of three realistic buildings were investigated. They were a commercial building, an industrial building and a dual-purpose building. The cooling loads per floor area for the buildings were studied and the OTTV were evaluated by two different methods. Sensitivity analysis was carried out to investigate the impact of the parameters of internal heat gains on the energy use of an academic building. It was found that there was major influence of indoor temperature setting on building energy use The performances of using the local weather data file of TMY and example weather years 1980 and 1989 were evaluated. TMY was found to be the most suitable for energy simulation while the weather years 1980 and 1989 yielded good results.
NASA Astrophysics Data System (ADS)
Basten, Van; Latief, Yusuf; Berawi, Mohammed Ali; Budiman, Rachmat; Riswanto
2017-03-01
Total completed building construction value in Indonesia increased 116% during 2009 to 2011. That's followed by increasing 11% energy consumption in Indonesia in the last three years with 70% energy met to the electricity needs of commercial building. In addition, a few application of green building concept in Indonesia made the greenhouse gas emissions or CO2 amount increased by 25%. Construction, operation, and maintain of building cost consider relatively high. The evaluation in this research is used to improve the building performance with some of green concept alternatives. The research methodology is conducted by combination of qualitative and quantitative approaches through interview and case study. Assessing the successful of optimization functions in the existing green building is based on the operational and maintenance phase with the Life Cycle Assessment (LCA) Method. The result of optimization that is the largest efficiency and effective of building life cycle.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Xiaodong, E-mail: eastdawn@tsinghua.edu.cn; Su, Shu, E-mail: sushuqh@163.com; Zhang, Zhihui, E-mail: zhzhg@tsinghua.edu.cn
To comprehensively pre-evaluate the damages to both the environment and human health due to construction activities in China, this paper presents an integrated building environmental and health performance (EHP) assessment model based on the Building Environmental Performance Analysis System (BEPAS) and the Building Health Impact Analysis System (BHIAS) models and offers a new inventory data estimation method. The new model follows the life cycle assessment (LCA) framework and the inventory analysis step involves bill of quantity (BOQ) data collection, consumption data formation, and environmental profile transformation. The consumption data are derived from engineering drawings and quotas to conduct the assessmentmore » before construction for pre-evaluation. The new model classifies building impacts into three safeguard areas: ecosystems, natural resources and human health. Thus, this model considers environmental impacts as well as damage to human wellbeing. The monetization approach, distance-to-target method and panel method are considered as optional weighting approaches. Finally, nine residential buildings of different structural types are taken as case studies to test the operability of the integrated model through application. The results indicate that the new model can effectively pre-evaluate building EHP and the structure type significantly affects the performance of residential buildings.« less
The post-evaluation of green residential building in Ningxia
NASA Astrophysics Data System (ADS)
Wu, Yunna; Wang, Zhen
2017-06-01
Green residential buildings are concerned by more and more people. However, the development of green residential buildings has been limited due to the single-standard requirements and lack of the multi-objective performance. At same time, the evaluation criteria system of green residential building is not comprehensive enough. So first of all, using SPSS software, residents questionnaire surveys are figured and found that the judge of experts and residents about the green elements is inconsistent, so the owners’ satisfaction is included in the post-evaluation criterial systems of green residential building from five aspects-the preliminary work of construction, construction process, economic, social benefits and owners satisfaction in Ningxia area, combined with expert interviews. Secondly, in the post-evaluation, it is difficult for many experts judgment matrix to meet the requirement of consistency, in this paper using MATLAB program, judgment matrix consistency is adjusted. And the weights of the criteria and sub-criteria and experts weights using group AHP method are determined. Finally, the grey clustering method is used to establish the post-evaluation model and the real case of Sai-shang project is carried out. It shows that the result obtained by using the improved criteria system and method in this paper is in a high degree of agreement with the actual result.
method for testing home energy audit software and associated calibration methods. BESTEST-EX is one of Energy Analysis Model Calibration Methods. When completed, the ANSI/RESNET SMOT will specify test procedures for evaluating calibration methods used in conjunction with predicting building energy use and
DOE Office of Scientific and Technical Information (OSTI.GOV)
Torcellini, Paul A.; Bonnema, Eric; Goldwasser, David
Building energy consumption can only be measured at the site or at the point of utility interconnection with a building. Often, to evaluate the total energy impact, this site-based energy consumption is translated into source energy, that is, the energy at the point of fuel extraction. Consistent with this approach, the U.S. Department of Energy's (DOE) definition of zero energy buildings uses source energy as the metric to account for energy losses from the extraction, transformation, and delivery of energy. Other organizations, as well, use source energy to characterize the energy impacts. Four methods of making the conversion from sitemore » energy to source energy were investigated in the context of the DOE definition of zero energy buildings. These methods were evaluated based on three guiding principles--improve energy efficiency, reduce and stabilize power demand, and use power from nonrenewable energy sources as efficiently as possible. This study examines relative trends between strategies as they are implemented on very low-energy buildings to achieve zero energy. A typical office building was modeled and variations to this model performed. The photovoltaic output that was required to create a zero energy building was calculated. Trends were examined with these variations to study the impacts of the calculation method on the building's ability to achieve zero energy status. The paper will highlight the different methods and give conclusions on the advantages and disadvantages of the methods studied.« less
This is the fourth, also the last, report of the report series entitled “Laboratory Study of Polychlorinated Biphenyl (PCB) Contamination and Mitigation in Buildings.” This report evaluates the performance of an on-site PCB destruction method, known as the AMTS method...
This is the fourth, also the last, report of the report series entitled “Laboratory Study of Polychlorinated Biphenyl (PCB) Contamination and Mitigation in Buildings.” This report evaluates the performance of an on-site PCB destruction method, known as the AMTS method, developed ...
Structural damages observed in state buildings after Simav/Turkey earthquake occurred on 19 May 2011
NASA Astrophysics Data System (ADS)
Tama, Y. S.
2012-08-01
Different levels of damages occurred in state buildings, especially in educational facilities, during the Simav earthquake (ML=5.7) on 19 May 2011. A site survey was carried out in the area after the earthquake, where six state buildings were examined in detail. The results of the survey showed that main reasons for the formation of damages in these buildings are the use of low strength concrete, insufficient reinforcement, inappropriate detailing, and low-quality workmanship. The investigated buildings were also evaluated by P25-rapid assessment method. The method demonstrates that two of the buildings in question are in "high risk band"; the other two fall into "detailed evaluation band", and the rest are in the "low risk band". This figure also matches with the damages observed in the site survey.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hayati, Arash Nemati; Stoll, Rob; Kim, J. J.
Three computational fluid dynamics (CFD) methods with different levels of flow-physics modelling are comprehensively evaluated against high-spatial-resolution wind-tunnel velocity data from step-down street canyons (i.e., a short building downwind of a tall building). The first method is a semi-empirical fast-response approach using the Quick Urban Industrial Complex (QUIC-URB) model. The second method solves the Reynolds-averaged Navier–Stokes (RANS) equations, and the third one utilizes a fully-coupled fluid-structure interaction large-eddy simulation (LES) model with a grid-turbulence inflow generator. Unlike typical point-by-point evaluation comparisons, here the entire two-dimensional wind-tunnel dataset is used to evaluate the dynamics of dominant flow topological features in themore » street canyon. Each CFD method is scrutinized for several geometric configurations by varying the downwind-to-upwind building-height ratio (H d/H u) and street canyon-width to building-width aspect ratio (S / W) for inflow winds perpendicular to the upwind building front face. Disparities between the numerical results and experimental data are quantified in terms of their ability to capture flow topological features for different geometric configurations. Ultimately, all three methods qualitatively predict the primary flow topological features, including a saddle point and a primary vortex. But, the secondary flow topological features, namely an in-canyon separation point and secondary vortices, are only well represented by the LES method despite its failure for taller downwind building cases. Misrepresentation of flow-regime transitions, exaggeration of the coherence of recirculation zones and wake fields, and overestimation of downwards vertical velocity into the canyon are the main defects in QUIC-URB, RANS and LES results, respectively. All three methods underestimate the updrafts and, surprisingly, QUIC-URB outperforms RANS for the streamwise velocity component, while RANS is superior to QUIC-URB for the vertical velocity component in the street canyon.« less
Hayati, Arash Nemati; Stoll, Rob; Kim, J. J.; ...
2017-05-18
Three computational fluid dynamics (CFD) methods with different levels of flow-physics modelling are comprehensively evaluated against high-spatial-resolution wind-tunnel velocity data from step-down street canyons (i.e., a short building downwind of a tall building). The first method is a semi-empirical fast-response approach using the Quick Urban Industrial Complex (QUIC-URB) model. The second method solves the Reynolds-averaged Navier–Stokes (RANS) equations, and the third one utilizes a fully-coupled fluid-structure interaction large-eddy simulation (LES) model with a grid-turbulence inflow generator. Unlike typical point-by-point evaluation comparisons, here the entire two-dimensional wind-tunnel dataset is used to evaluate the dynamics of dominant flow topological features in themore » street canyon. Each CFD method is scrutinized for several geometric configurations by varying the downwind-to-upwind building-height ratio (H d/H u) and street canyon-width to building-width aspect ratio (S / W) for inflow winds perpendicular to the upwind building front face. Disparities between the numerical results and experimental data are quantified in terms of their ability to capture flow topological features for different geometric configurations. Ultimately, all three methods qualitatively predict the primary flow topological features, including a saddle point and a primary vortex. But, the secondary flow topological features, namely an in-canyon separation point and secondary vortices, are only well represented by the LES method despite its failure for taller downwind building cases. Misrepresentation of flow-regime transitions, exaggeration of the coherence of recirculation zones and wake fields, and overestimation of downwards vertical velocity into the canyon are the main defects in QUIC-URB, RANS and LES results, respectively. All three methods underestimate the updrafts and, surprisingly, QUIC-URB outperforms RANS for the streamwise velocity component, while RANS is superior to QUIC-URB for the vertical velocity component in the street canyon.« less
NASA Astrophysics Data System (ADS)
Hayati, Arash Nemati; Stoll, Rob; Kim, J. J.; Harman, Todd; Nelson, Matthew A.; Brown, Michael J.; Pardyjak, Eric R.
2017-08-01
Three computational fluid dynamics (CFD) methods with different levels of flow-physics modelling are comprehensively evaluated against high-spatial-resolution wind-tunnel velocity data from step-down street canyons (i.e., a short building downwind of a tall building). The first method is a semi-empirical fast-response approach using the Quick Urban Industrial Complex (QUIC-URB) model. The second method solves the Reynolds-averaged Navier-Stokes (RANS) equations, and the third one utilizes a fully-coupled fluid-structure interaction large-eddy simulation (LES) model with a grid-turbulence inflow generator. Unlike typical point-by-point evaluation comparisons, here the entire two-dimensional wind-tunnel dataset is used to evaluate the dynamics of dominant flow topological features in the street canyon. Each CFD method is scrutinized for several geometric configurations by varying the downwind-to-upwind building-height ratio (H_d/H_u) and street canyon-width to building-width aspect ratio ( S / W) for inflow winds perpendicular to the upwind building front face. Disparities between the numerical results and experimental data are quantified in terms of their ability to capture flow topological features for different geometric configurations. Overall, all three methods qualitatively predict the primary flow topological features, including a saddle point and a primary vortex. However, the secondary flow topological features, namely an in-canyon separation point and secondary vortices, are only well represented by the LES method despite its failure for taller downwind building cases. Misrepresentation of flow-regime transitions, exaggeration of the coherence of recirculation zones and wake fields, and overestimation of downwards vertical velocity into the canyon are the main defects in QUIC-URB, RANS and LES results, respectively. All three methods underestimate the updrafts and, surprisingly, QUIC-URB outperforms RANS for the streamwise velocity component, while RANS is superior to QUIC-URB for the vertical velocity component in the street canyon.
Comparison of calculation and simulation of evacuation in real buildings
NASA Astrophysics Data System (ADS)
Szénay, Martin; Lopušniak, Martin
2018-03-01
Each building must meet requirements for safe evacuation in order to prevent casualties. Therefore methods for evaluation of evacuation are used when designing buildings. In the paper, calculation methods were tested on three real buildings. The testing used methods of evacuation time calculation pursuant to Slovak standards and evacuation time calculation using the buildingExodus simulation software. If calculation methods have been suitably selected taking into account the nature of evacuation and at the same time if correct values of parameters were entered, we will be able to obtain almost identical times of evacuation in comparison with real results obtained from simulation. The difference can range from 1% to 27%.
The Evaluator's Perspective: Evaluating the State Capacity Building Program.
ERIC Educational Resources Information Center
Madey, Doren L.
A historical antagonism between the advocates of quantitative evaluation methods and the proponents of qualitative evaluation methods has stymied the recognition of the value to be gained by utilizing both methodologies in the same study. The integration of quantitative and qualitative methods within a single evaluation has synergistic effects in…
Evaluating investment in quality improvement capacity building: a systematic review
Mery, Gustavo; Dobrow, Mark J; Baker, G Ross; Im, Jennifer; Brown, Adalsteinn
2017-01-01
Purpose Leading health systems have invested in substantial quality improvement (QI) capacity building, but little is known about the aggregate effect of these investments at the health system level. We conducted a systematic review to identify key steps and elements that should be considered for system-level evaluations of investment in QI capacity building. Methods We searched for evaluations of QI capacity building and evaluations of QI training programmes. We included the most relevant indexed databases in the field and a strategic search of the grey literature. The latter included direct electronic scanning of 85 relevant government and institutional websites internationally. Data were extracted regarding evaluation design and common assessment themes and components. Results 48 articles met the inclusion criteria. 46 articles described initiative-level non-economic evaluations of QI capacity building/training, while 2 studies included economic evaluations of QI capacity building/training, also at the initiative level. No system-level QI capacity building/training evaluations were found. We identified 17 evaluation components that fit within 5 overarching dimensions (characteristics of QI training; characteristics of QI activity; individual capacity; organisational capacity and impact) that should be considered in evaluations of QI capacity building. 8 key steps in return-on-investment (ROI) assessments in QI capacity building were identified: (1) planning—stakeholder perspective; (2) planning—temporal perspective; (3) identifying costs; (4) identifying benefits; (5) identifying intangible benefits that will not be included in the ROI estimation; (6) discerning attribution; (7) ROI calculations; (8) sensitivity analysis. Conclusions The literature on QI capacity building evaluation is limited in the number and scope of studies. Our findings, summarised in a Framework to Guide Evaluations of QI Capacity Building, can be used to start closing this knowledge gap. PMID:28219957
DOT National Transportation Integrated Search
2010-06-10
Two primary contracting methods are used by most state transportation agencies to : design and build infrastructure: design-bid-build and design-build. The objective : of this study is to conduct a literature review to identify how ConnDOTs use of...
A risk evaluation model and its application in online retailing trustfulness
NASA Astrophysics Data System (ADS)
Ye, Ruyi; Xu, Yingcheng
2017-08-01
Building a general model for risks evaluation in advance could improve the convenience, normality and comparability of the results of repeating risks evaluation in the case that the repeating risks evaluating are in the same area and for a similar purpose. One of the most convenient and common risks evaluation models is an index system including of several index, according weights and crediting method. One method to build a risk evaluation index system that guarantees the proportional relationship between the resulting credit and the expected risk loss is proposed and an application example is provided in online retailing in this article.
Application of BIM Technology in Building Water Supply and Drainage Design
NASA Astrophysics Data System (ADS)
Wei, Tianyun; Chen, Guiqing; Wang, Junde
2017-12-01
Through the application of BIM technology, the idea of building water supply and drainage designers can be related to the model, the various influencing factors to affect water supply and drainage design can be considered more comprehensively. BIM(Building information model) technology assist in improving the design process of building water supply and drainage, promoting the building water supply and drainage planning, enriching the building water supply and drainage design method, improving the water supply and drainage system design level and building quality. Combined with fuzzy comprehensive evaluation method to analyze the advantages of BIM technology in building water supply and drainage design. Therefore, application prospects of BIM technology are very worthy of promotion.
NASA Astrophysics Data System (ADS)
Majerek, Dariusz; Guz, Łukasz; Suchorab, Zbigniew; Łagód, Grzegorz; Sobczuk, Henryk
2017-07-01
Mold that develops on moistened building barriers is a major cause of the Sick Building Syndrome (SBS). Fungal contamination is normally evaluated using standard biological methods which are time-consuming and require a lot of manual labor. Fungi emit Volatile Organic Compounds (VOC) that can be detected in the indoor air using several techniques of detection e.g. chromatography. VOCs can be also detected using gas sensors arrays. All array sensors generate particular voltage signals that ought to be analyzed using properly selected statistical methods of interpretation. This work is focused on the attempt to apply statistical classifying models in evaluation of signals from gas sensors matrix to analyze the air sampled from the headspace of various types of the building materials at different level of contamination but also clean reference materials.
ERIC Educational Resources Information Center
Brinkerhoff, Robert O.; Dressler, Dennis
2002-01-01
Discusses the causes of variability of training impact and problems with previous models for evaluation of training. Presents the Success Case Evaluation approach as a way to measure the impact of training and build learning capability to increase the business value of training by focusing on a small number of trainees. (Author/LRW)
NASA Astrophysics Data System (ADS)
Liang, Li; Takaaki, Ohkubo; Guang-hui, Li
2018-03-01
In recent years, earthquakes have occurred frequently, and the seismic performance of existing school buildings has become particularly important. The main method for improving the seismic resistance of existing buildings is reinforcement. However, there are few effective methods to evaluate the effect of reinforcement. Ambient vibration measurement experiments were conducted before and after seismic retrofitting using wireless measurement system and the changes of vibration characteristics were compared. The changes of acceleration response spectrum, natural periods and vibration modes indicate that the wireless vibration measurement system can be effectively applied to evaluate the effect of seismic retrofitting. The method can evaluate the effect of seismic retrofitting qualitatively, it is difficult to evaluate the effect of seismic retrofitting quantitatively at this stage.
IEA EBC annex 53: Total energy use in buildings—Analysis and evaluation methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yoshino, Hiroshi; Hong, Tianzhen; Nord, Natasa
One of the most significant barriers to achieving deep building energy efficiency is a lack of knowledge about the factors determining energy use. In fact, there is often a significant discrepancy between designed and real energy use in buildings, which is poorly understood but are believed to have more to do with the role of human behavior than building design. Building energy use is mainly influenced by six factors: climate, building envelope, building services and energy systems, building operation and maintenance, occupants’ activities and behavior, and indoor environmental quality. In the past, much research focused on the first three factors.more » However, the next three human-related factors can have an influence as significant as the first three. Annex 53 employed an interdisciplinary approach, integrating building science, architectural engineering, computer modeling and simulation, and social and behavioral science to develop and apply methods to analyze and evaluate the real energy use in buildings considering the six influencing factors. Finally, outcomes from Annex 53 improved understanding and strengthen knowledge regarding the robust prediction of total energy use in buildings, enabling reliable quantitative assessment of energy-savings measures, policies, and techniques.« less
IEA EBC annex 53: Total energy use in buildings—Analysis and evaluation methods
Yoshino, Hiroshi; Hong, Tianzhen; Nord, Natasa
2017-07-18
One of the most significant barriers to achieving deep building energy efficiency is a lack of knowledge about the factors determining energy use. In fact, there is often a significant discrepancy between designed and real energy use in buildings, which is poorly understood but are believed to have more to do with the role of human behavior than building design. Building energy use is mainly influenced by six factors: climate, building envelope, building services and energy systems, building operation and maintenance, occupants’ activities and behavior, and indoor environmental quality. In the past, much research focused on the first three factors.more » However, the next three human-related factors can have an influence as significant as the first three. Annex 53 employed an interdisciplinary approach, integrating building science, architectural engineering, computer modeling and simulation, and social and behavioral science to develop and apply methods to analyze and evaluate the real energy use in buildings considering the six influencing factors. Finally, outcomes from Annex 53 improved understanding and strengthen knowledge regarding the robust prediction of total energy use in buildings, enabling reliable quantitative assessment of energy-savings measures, policies, and techniques.« less
MEASUREMENT OF VOCS DESORBED FROM BUILDING MATERIALS--A HIGH TEMPERATURE DYNAMIC CHAMBER METHOD
Mass balance is a commonly used approach for characterizing the source and sink behavior of building materials. Because the traditional sink test methods evaluate the adsorption and desorption of volatile organic compounds (VOC) at ambient temperatures, the desorption process is...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurnik, Charles W.; Romberger, Jeff
The HVAC Controls Evaluation Protocol is designed to address evaluation issues for direct digital controls/energy management systems/building automation systems (DDC/EMS/BAS) that are installed to control heating, ventilation, and air-conditioning (HVAC) equipment in commercial and institutional buildings. (This chapter refers to the DDC/EMS/BAS measure as HVAC controls.) This protocol may also be applicable to industrial facilities such as clean rooms and labs, which have either significant HVAC equipment or spaces requiring special environmental conditions.
Economic Evaluation of Building Design, Construction, Operation and Maintenance. Seminar Workbook.
ERIC Educational Resources Information Center
Ruegg, Rosalie T.
This workbook has been prepared for participants in the seminar, "Economic Evaluation of Building Design, Construction, Operation and Maintenance." It has two main functions: (1) to provide basic resource materials, references, and introductions to methods employed in the seminar; and (2) to provide instructional problems for solution by…
Fundamental Characteristics For Building Dymanics Obtained From Microtremors Measurements.
NASA Astrophysics Data System (ADS)
Enomoto, T.; Abeki, N.; Kuramochi, D.; Lanuza, A.; Gonzalez, J.; Schmitz, M.; Navarro, M.
We are performing the international joint research investigations for the seismic disaster mitigation in Metro Manila between Philippine and Japan from 1994, in Caracas between Venezuela and Japan from 1996 and also in Almeria and Granada between Spain and Japan from 1996. We have made the microtremor measurements at Reinforced Concrete (RC) buildings existed in these cities and evaluated the dynamical characteristics of RC buildings, natural period and damping factor. Even if it·fs necessary to have some discussions about the accuracy of microtremor measurement in order to evaluate the dynamical characteristics because of small amplitude range phenomena. However, the microtremor measurement method is a simple, low cost and realistic method in order to observe and investigate the actual dynamical behavior for obtaining the useful information in many countries. In these international joint research works, we settled the main object to the getting useful information of building dynamical characteristics for the seismic disaster mitigation. So, we observed microtremors at the top floor of several kinds of buildings which have the different conditions, for examples, existed place, building type, dimensional scale and number of stories etc. Then we realized the evaluation of natural period and responded damping factor of building depending on the building conditions as a statistical tendencies. In this paper, mainly we would like to present the investigated results of regression relationship between the natural period of RC building and the number of stories in Philippine and Venezuela, respectively. and also, we summarized the relationship between the natural period of RC building and damping factor considering the surrounding soil condition. We thought that these relations are reasonable and believable results in the small amplitude range evaluated from microtremors.
Structural building screening and evaluation
NASA Astrophysics Data System (ADS)
Kurniawandy, Alex; Nakazawa, Shoji; Hendry, Andy; Ridwan, Firdaus, Rahmatul
2017-10-01
An earthquake is a disaster that can be harmful to the community, such as financial loss and also dead injuries. Pekanbaru is a city that located in the middle of Sumatera Island. Even though the city of Pekanbaru is a city that rarely occurs earthquake, but Pekanbaru has ever felt the impact of the big earthquake that occurred in West Sumatera on September 2009. As we know, Indonesia located between Eurasia plate, Pacific plate, and Indo-Australian plate. Particularly the Sumatera Island, It has the Semangko fault or the great Sumatra fault along the island from north to south due to the shift of Eurasia and Indo-Australian Plates. An earthquake is not killing people but the building around the people that could be killing them. The failure of the building can be early prevented by doing an evaluation. In this research, the methods of evaluation have used a guideline for the Federal Emergency Management Agency (FEMA) P-154 and Applied Technology Council (ATC) 40. FEMA P-154 is a rapid visual screening of buildings for potential seismic hazards and ATC-40 is seismic evaluation and retrofit of Concrete Buildings. ATC-40 is a more complex evaluation rather than FEMA P-154. The samples to be evaluated are taken in the surroundings of Universitas Riau facility in Pekanbaru. There are four buildings as case study such as the rent student building, the building of mathematics and natural science faculty, the building teacher training and education faculty and the buildings in the faculty of Social political sciences. Vulnerability for every building facing an earthquake is different, this is depending on structural and non-structural components of the building. Among all of the samples, only the building of mathematics and the natural science faculty is in critical condition according to the FEMA P-154 evaluation. Furthermore, the results of evaluation using ATC-40 for the teacher training building are in damage control conditions, despite the other three buildings are in immediate occupancy conditions.
Evaluation Methods of The Text Entities
ERIC Educational Resources Information Center
Popa, Marius
2006-01-01
The paper highlights some evaluation methods to assess the quality characteristics of the text entities. The main concepts used in building and evaluation processes of the text entities are presented. Also, some aggregated metrics for orthogonality measurements are presented. The evaluation process for automatic evaluation of the text entities is…
NASA Astrophysics Data System (ADS)
Chen, J.; Chen, W.; Dou, A.; Li, W.; Sun, Y.
2018-04-01
A new information extraction method of damaged buildings rooted in optimal feature space is put forward on the basis of the traditional object-oriented method. In this new method, ESP (estimate of scale parameter) tool is used to optimize the segmentation of image. Then the distance matrix and minimum separation distance of all kinds of surface features are calculated through sample selection to find the optimal feature space, which is finally applied to extract the image of damaged buildings after earthquake. The overall extraction accuracy reaches 83.1 %, the kappa coefficient 0.813. The new information extraction method greatly improves the extraction accuracy and efficiency, compared with the traditional object-oriented method, and owns a good promotional value in the information extraction of damaged buildings. In addition, the new method can be used for the information extraction of different-resolution images of damaged buildings after earthquake, then to seek the optimal observation scale of damaged buildings through accuracy evaluation. It is supposed that the optimal observation scale of damaged buildings is between 1 m and 1.2 m, which provides a reference for future information extraction of damaged buildings.
NASA Astrophysics Data System (ADS)
Tu, Jihui; Sui, Haigang; Feng, Wenqing; Song, Zhina
2016-06-01
In this paper, a novel approach of building damaged detection is proposed using high resolution remote sensing images and 3D GIS-Model data. Traditional building damage detection method considers to detect damaged building due to earthquake, but little attention has been paid to analyze various building damaged types(e.g., trivial damaged, severely damaged and totally collapsed.) Therefore, we want to detect the different building damaged type using 2D and 3D feature of scenes because the real world we live in is a 3D space. The proposed method generalizes that the image geometric correction method firstly corrects the post-disasters remote sensing image using the 3D GIS model or RPC parameters, then detects the different building damaged types using the change of the height and area between the pre- and post-disasters and the texture feature of post-disasters. The results, evaluated on a selected study site of the Beichuan earthquake ruins, Sichuan, show that this method is feasible and effective in building damage detection. It has also shown that the proposed method is easily applicable and well suited for rapid damage assessment after natural disasters.
Levels of polychlorinated biphenyls (PCBs) in caulk and window glazing material samples from older buildings were determined, using a method developed for this purpose. This method was evaluated by analyzing a combination of 47 samples of caulk, glazing materials, including quali...
ERIC Educational Resources Information Center
Graham, Charles W.; Geva, Anat
2001-01-01
An interdisciplinary studio project involved architecture and construction students. Evaluation of the integrated studio experience found that it gave students an accurate picture of professional practice. Architecture students were made more aware of building materials, construction technology, and cost; construction science students better…
A Research Synthesis of the Evaluation Capacity Building Literature
ERIC Educational Resources Information Center
Labin, Susan N.; Duffy, Jennifer L.; Meyers, Duncan C.; Wandersman, Abraham; Lesesne, Catherine A.
2012-01-01
The continuously growing demand for program results has produced an increased need for evaluation capacity building (ECB). The "Integrative ECB Model" was developed to integrate concepts from existing ECB theory literature and to structure a synthesis of the empirical ECB literature. The study used a broad-based research synthesis method with…
ERIC Educational Resources Information Center
Ornstein, Sheila Walbe; Moreira, Nanci Saraiva; Ono, Rosaria; Limongi Franca, Ana J. G.; Nogueira, Roselene A. M. F.
2009-01-01
Purpose: The paper describes the purpose of and strategies for conducting post-occupancy evaluations (POEs) as a method for assessing school building performance. Set within the larger context of global efforts to develop and apply common indicators of school building quality, the authors describe research conducted within the newest generation of…
Reconstruction of Building Outlines in Dense Urban Areas Based on LIDAR Data and Address Points
NASA Astrophysics Data System (ADS)
Jarzabek-Rychard, M.
2012-07-01
The paper presents a comprehensive method for automated extraction and delineation of building outlines in densely built-up areas. A novel approach to outline reconstruction is the use of geocoded building address points. They give information about building location thus highly reduce task complexity. Reconstruction process is executed on 3D point clouds acquired by airborne laser scanner. The method consists of three steps: building detection, delineation and contours refinement. The algorithm is tested against a data set that presents the old market town and its surroundings. The results are discussed and evaluated by comparison to reference cadastral data.
Sexual Health Promotion Programme: Participants' Perspectives on Capacity Building
ERIC Educational Resources Information Center
Keogh, Brian; Daly, Louise; Sharek, Danika; De Vries, Jan; McCann, Edward; Higgins, Agnes
2016-01-01
Objectives: The aim of this study was to evaluate a Health Service Executive (HSE) Foundation Programme in Sexual Health Promotion (FPSHP) with a specific emphasis on capacity building. Design: A mixed-method design using both quantitative and qualitative methods was used to collect the data. Setting: The FPSHP was delivered to staff working in…
Evaluation of Model Recognition for Grammar-Based Automatic 3d Building Model Reconstruction
NASA Astrophysics Data System (ADS)
Yu, Qian; Helmholz, Petra; Belton, David
2016-06-01
In recent years, 3D city models are in high demand by many public and private organisations, and the steadily growing capacity in both quality and quantity are increasing demand. The quality evaluation of these 3D models is a relevant issue both from the scientific and practical points of view. In this paper, we present a method for the quality evaluation of 3D building models which are reconstructed automatically from terrestrial laser scanning (TLS) data based on an attributed building grammar. The entire evaluation process has been performed in all the three dimensions in terms of completeness and correctness of the reconstruction. Six quality measures are introduced to apply on four datasets of reconstructed building models in order to describe the quality of the automatic reconstruction, and also are assessed on their validity from the evaluation point of view.
EVALUATION OF AEROSOLIZATION OF ASBESTOS AND RELATED FIBERS FROM BULK MATERIALS
1. Status Report on the Evaluation of the Alternative Asbestos Control Method – A Comparison to the NESHAP Method of Demolition of Asbestos Containing Buildings; and, 2. Update on the Evaluation of Aerosolization of Asbestos and Related Fibers from Bulk Materials. This abstract a...
Application of Various NDT Methods for the Evaluation of Building Steel Structures for Reuse
Fujita, Masanori; Masuda, Tomoya
2014-01-01
The reuse system proposed by the authors is an overall business system for realizing a cyclic reuse flow through the processes of design, fabrication, construction, maintenance, demolition and storage. The reuse system is one of the methods to reduce the environmental burden in the field of building steel structures. These buildings are assumed to be demolished within approximately 30 years or more for physical, architectural, economic and social reasons in Japan. In this paper, focusing on building steel structures used for plants, warehouses and offices without fire protection, the performance of steel structural members for reuse is evaluated by a non-destructive test. First, performance evaluation procedures for a non-destructive test, such as mechanical properties, chemical compositions, dimension and degradation, are shown. Tensile strengths are estimated using Vickers hardness measured by a portable ultrasonic hardness tester, and chemical compositions are measured by a portable optical emission spectrometer. The weldability of steel structural members is estimated by carbon equivalent and weld crack sensitivity composition using chemical compositions. Finally, the material grade of structural members of the building steel structure for reuse is estimated based on the proposed procedures. PMID:28788237
Application of Various NDT Methods for the Evaluation of Building Steel Structures for Reuse.
Fujita, Masanori; Masuda, Tomoya
2014-10-22
The reuse system proposed by the authors is an overall business system for realizing a cyclic reuse flow through the processes of design, fabrication, construction, maintenance, demolition and storage. The reuse system is one of the methods to reduce the environmental burden in the field of building steel structures. These buildings are assumed to be demolished within approximately 30 years or more for physical, architectural, economic and social reasons in Japan. In this paper, focusing on building steel structures used for plants, warehouses and offices without fire protection, the performance of steel structural members for reuse is evaluated by a non-destructive test. First, performance evaluation procedures for a non-destructive test, such as mechanical properties, chemical compositions, dimension and degradation, are shown. Tensile strengths are estimated using Vickers hardness measured by a portable ultrasonic hardness tester, and chemical compositions are measured by a portable optical emission spectrometer. The weldability of steel structural members is estimated by carbon equivalent and weld crack sensitivity composition using chemical compositions. Finally, the material grade of structural members of the building steel structure for reuse is estimated based on the proposed procedures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Yixing; Hong, Tianzhen
We present that urban-scale building energy modeling (UBEM)—using building modeling to understand how a group of buildings will perform together—is attracting increasing attention in the energy modeling field. Unlike modeling a single building, which will use detailed information, UBEM generally uses existing building stock data consisting of high-level building information. This study evaluated the impacts of three zoning methods and the use of floor multipliers on the simulated energy use of 940 office and retail buildings in three climate zones using City Building Energy Saver. The first zoning method, OneZone, creates one thermal zone per floor using the target building'smore » footprint. The second zoning method, AutoZone, splits the building's footprint into perimeter and core zones. A novel, pixel-based automatic zoning algorithm is developed for the AutoZone method. The third zoning method, Prototype, uses the U.S. Department of Energy's reference building prototype shapes. Results show that simulated source energy use of buildings with the floor multiplier are marginally higher by up to 2.6% than those modeling each floor explicitly, which take two to three times longer to run. Compared with the AutoZone method, the OneZone method results in decreased thermal loads and less equipment capacities: 15.2% smaller fan capacity, 11.1% smaller cooling capacity, 11.0% smaller heating capacity, 16.9% less heating loads, and 7.5% less cooling loads. Source energy use differences range from -7.6% to 5.1%. When comparing the Prototype method with the AutoZone method, source energy use differences range from -12.1% to 19.0%, and larger ranges of differences are found for the thermal loads and equipment capacities. This study demonstrated that zoning methods have a significant impact on the simulated energy use of UBEM. Finally, one recommendation resulting from this study is to use the AutoZone method with floor multiplier to obtain accurate results while balancing the simulation run time for UBEM.« less
Chen, Yixing; Hong, Tianzhen
2018-02-20
We present that urban-scale building energy modeling (UBEM)—using building modeling to understand how a group of buildings will perform together—is attracting increasing attention in the energy modeling field. Unlike modeling a single building, which will use detailed information, UBEM generally uses existing building stock data consisting of high-level building information. This study evaluated the impacts of three zoning methods and the use of floor multipliers on the simulated energy use of 940 office and retail buildings in three climate zones using City Building Energy Saver. The first zoning method, OneZone, creates one thermal zone per floor using the target building'smore » footprint. The second zoning method, AutoZone, splits the building's footprint into perimeter and core zones. A novel, pixel-based automatic zoning algorithm is developed for the AutoZone method. The third zoning method, Prototype, uses the U.S. Department of Energy's reference building prototype shapes. Results show that simulated source energy use of buildings with the floor multiplier are marginally higher by up to 2.6% than those modeling each floor explicitly, which take two to three times longer to run. Compared with the AutoZone method, the OneZone method results in decreased thermal loads and less equipment capacities: 15.2% smaller fan capacity, 11.1% smaller cooling capacity, 11.0% smaller heating capacity, 16.9% less heating loads, and 7.5% less cooling loads. Source energy use differences range from -7.6% to 5.1%. When comparing the Prototype method with the AutoZone method, source energy use differences range from -12.1% to 19.0%, and larger ranges of differences are found for the thermal loads and equipment capacities. This study demonstrated that zoning methods have a significant impact on the simulated energy use of UBEM. Finally, one recommendation resulting from this study is to use the AutoZone method with floor multiplier to obtain accurate results while balancing the simulation run time for UBEM.« less
A Comparison of Two Balance Calibration Model Building Methods
NASA Technical Reports Server (NTRS)
DeLoach, Richard; Ulbrich, Norbert
2007-01-01
Simulated strain-gage balance calibration data is used to compare the accuracy of two balance calibration model building methods for different noise environments and calibration experiment designs. The first building method obtains a math model for the analysis of balance calibration data after applying a candidate math model search algorithm to the calibration data set. The second building method uses stepwise regression analysis in order to construct a model for the analysis. Four balance calibration data sets were simulated in order to compare the accuracy of the two math model building methods. The simulated data sets were prepared using the traditional One Factor At a Time (OFAT) technique and the Modern Design of Experiments (MDOE) approach. Random and systematic errors were introduced in the simulated calibration data sets in order to study their influence on the math model building methods. Residuals of the fitted calibration responses and other statistical metrics were compared in order to evaluate the calibration models developed with different combinations of noise environment, experiment design, and model building method. Overall, predicted math models and residuals of both math model building methods show very good agreement. Significant differences in model quality were attributable to noise environment, experiment design, and their interaction. Generally, the addition of systematic error significantly degraded the quality of calibration models developed from OFAT data by either method, but MDOE experiment designs were more robust with respect to the introduction of a systematic component of the unexplained variance.
Monitoring the Error Rate of Modern Methods of Construction Based on Wood
NASA Astrophysics Data System (ADS)
Švajlenka, Jozef; Kozlovská, Mária
2017-06-01
A range of new and innovative construction systems, currently developed, represent modern methods of construction (MMC), which has the ambition to improve the performance parameters of buildings throughout their life cycle. Regarding the implementation modern methods of construction in Slovakia, assembled buildings based on wood seem to be the most preferred construction system. In the study, presented in the paper, were searched already built and lived-in wood based family houses. The residents' attitudes to such type of buildings in the context with declared designing and qualitative parameters of efficiency and sustainability are overlooked. The methodology of the research study is based on the socio-economic survey carried out during the years 2015 - 2017 within the Slovak Republic. Due to the large extent of data collected through questionnaire, only selected parts of the survey results are evaluated and discussed in the paper. This paper is aimed at evaluating the quality of buildings expressed in a view of users of existing wooden buildings. Research indicates some defects, which can be eliminated in the next production process. Research indicates, that some defects occur, so the production process quality should be improved in the future development.
Program for developing and implementing a new approach to designing for fire safety in buildings
NASA Technical Reports Server (NTRS)
1975-01-01
The traditional method of providing for fire safety in buildings through reliance on codes and standards that prescribe specific measures to be taken in the design and construction of buildings to minimize the potential for a fire occurring and to protect property and life should a fire occur was evaluated. A new approach to designing for fire safety in buildings is outlined.
NASA Astrophysics Data System (ADS)
Singh, Vipul
2011-12-01
The green building movement has been an effective catalyst in reducing energy demands of buildings and a large number of 'green' certified buildings have been in operation for several years. Whether these buildings are actually performing as intended, and if not, identifying specific causes for this discrepancy falls into the general realm of post-occupancy evaluation (POE). POE involves evaluating building performance in terms of energy-use, indoor environmental quality, acoustics and water-use; the first aspect i.e. energy-use is addressed in this thesis. Normally, a full year or more of energy-use and weather data is required to determine the actual post-occupancy energy-use of buildings. In many cases, either measured building performance data is not available or the time and cost implications may not make it feasible to invest in monitoring the building for a whole year. Knowledge about the minimum amount of measured data needed to accurately capture the behavior of the building over the entire year can be immensely beneficial. This research identifies simple modeling techniques to determine best time of the year to begin in-situ monitoring of building energy-use, and the least amount of data required for generating acceptable long-term predictions. Four analysis procedures are studied. The short-term monitoring for long-term prediction (SMLP) approach and dry-bulb temperature analysis (DBTA) approach allow determining the best time and duration of the year for in-situ monitoring to be performed based only on the ambient temperature data of the location. Multivariate change-point (MCP) modeling uses simulated/monitored data to determine best monitoring period of the year. This is also used to validate the SMLP and DBTA approaches. The hybrid inverse modeling method-1 predicts energy-use by combining a short dataset of monitored internal loads with a year of utility-bills, and hybrid inverse method-2 predicts long term building performance using utility-bills only. The results obtained show that often less than three to four months of monitored data is adequate for estimating the annual building energy use, provided that the monitoring is initiated at the right time, and the seasonal as well as daily variations are adequately captured by the short dataset. The predictive accuracy of the short data-sets is found to be strongly influenced by the closeness of the dataset's mean temperature to the annual average temperature. The analysis methods studied would be very useful for energy professionals involved in POE.
ERIC Educational Resources Information Center
Foster, Bruce E., Ed.
Volume 1 contains all the invited papers accepted for the symposium. The subject matter covered in the papers includes physiological, anthropometrical, psychological, sociological, and economic human requirements and methods of evaluation; physical requirements and methods of evaluation in mechanical, acoustical, thermal, dimensional stability,…
Energy performance assessment with empirical methods: application of energy signature
NASA Astrophysics Data System (ADS)
Belussi, L.; Danza, L.; Meroni, I.; Salamone, F.
2015-03-01
Energy efficiency and reduction of building consumption are deeply felt issues both at Italian and international level. The recent regulatory framework sets stringent limits on energy performance of buildings. Awaiting the adoption of these principles, several methods have been developed to solve the problem of energy consumption of buildings, among which the simplified energy audit is intended to identify any anomalies in the building system, to provide helpful tips for energy refurbishments and to raise end users' awareness. The Energy Signature is an operational tool of these methodologies, an evaluation method in which energy consumption is correlated with climatic variables, representing the actual energy behaviour of the building. In addition to that purpose, the Energy Signature can be used as an empirical tool to determine the real performances of the technical elements. The latter aspect is illustrated in this article.
Multicriteria Analysis of Assembling Buildings from Steel Frame Structures
NASA Astrophysics Data System (ADS)
Miniotaite, Ruta
2017-10-01
Steel frame structures are often used in the construction of public and industrial buildings. They are used for: all types of slope roofs; walls of newly-built public and industrial buildings; load bearing structures; roofs of renovated buildings. The process of assembling buildings from steel frame structures should be analysed as an integrated process influenced by such factors as construction materials and machinery used, the qualification level of construction workers, complexity of work, available finance. It is necessary to find a rational technological design solution for assembling buildings from steel frame structures by conducting a multiple criteria analysis. The analysis provides a possibility to evaluate the engineering considerations and find unequivocal solutions. The rational alternative of a complex process of assembling buildings from steel frame structures was found through multiple criteria analysis and multiple criteria evaluation. In multiple criteria evaluation of technological solutions for assembling buildings from steel frame structures by pairwise comparison method the criteria by significance are distributed as follows: durability is the most important criterion in the evaluation of alternatives; the price (EUR/unit of measurement) of a part of assembly process; construction workers’ qualification level (category); mechanization level of a part of assembling process (%), and complexity of assembling work (in points) are less important criteria.
Evaluation of Automated Model Calibration Techniques for Residential Building Energy Simulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robertson, J.; Polly, B.; Collis, J.
2013-09-01
This simulation study adapts and applies the general framework described in BESTEST-EX (Judkoff et al 2010) for self-testing residential building energy model calibration methods. BEopt/DOE-2.2 is used to evaluate four mathematical calibration methods in the context of monthly, daily, and hourly synthetic utility data for a 1960's-era existing home in a cooling-dominated climate. The home's model inputs are assigned probability distributions representing uncertainty ranges, random selections are made from the uncertainty ranges to define 'explicit' input values, and synthetic utility billing data are generated using the explicit input values. The four calibration methods evaluated in this study are: an ASHRAEmore » 1051-RP-based approach (Reddy and Maor 2006), a simplified simulated annealing optimization approach, a regression metamodeling optimization approach, and a simple output ratio calibration approach. The calibration methods are evaluated for monthly, daily, and hourly cases; various retrofit measures are applied to the calibrated models and the methods are evaluated based on the accuracy of predicted savings, computational cost, repeatability, automation, and ease of implementation.« less
Evaluation of Automated Model Calibration Techniques for Residential Building Energy Simulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
and Ben Polly, Joseph Robertson; Polly, Ben; Collis, Jon
2013-09-01
This simulation study adapts and applies the general framework described in BESTEST-EX (Judkoff et al 2010) for self-testing residential building energy model calibration methods. BEopt/DOE-2.2 is used to evaluate four mathematical calibration methods in the context of monthly, daily, and hourly synthetic utility data for a 1960's-era existing home in a cooling-dominated climate. The home's model inputs are assigned probability distributions representing uncertainty ranges, random selections are made from the uncertainty ranges to define "explicit" input values, and synthetic utility billing data are generated using the explicit input values. The four calibration methods evaluated in this study are: an ASHRAEmore » 1051-RP-based approach (Reddy and Maor 2006), a simplified simulated annealing optimization approach, a regression metamodeling optimization approach, and a simple output ratio calibration approach. The calibration methods are evaluated for monthly, daily, and hourly cases; various retrofit measures are applied to the calibrated models and the methods are evaluated based on the accuracy of predicted savings, computational cost, repeatability, automation, and ease of implementation.« less
Misso, Marie L; Ilic, Dragan; Haines, Terry P; Hutchinson, Alison M; East, Christine E; Teede, Helena J
2016-01-14
Health professionals need to be integrated more effectively in clinical research to ensure that research addresses clinical needs and provides practical solutions at the coal face of care. In light of limited evidence on how best to achieve this, evaluation of strategies to introduce, adapt and sustain evidence-based practices across different populations and settings is required. This project aims to address this gap through the co-design, development, implementation, evaluation, refinement and ultimately scale-up of a clinical research engagement and leadership capacity building program in a clinical setting with little to no co-ordinated approach to clinical research engagement and education. The protocol is based on principles of research capacity building and on a six-step framework, which have previously led to successful implementation and long-term sustainability. A mixed methods study design will be used. Methods will include: (1) a review of the literature about strategies that engage health professionals in research through capacity building and/or education in research methods; (2) a review of existing local research education and support elements; (3) a needs assessment in the local clinical setting, including an online cross-sectional survey and semi-structured interviews; (4) co-design and development of an educational and support program; (5) implementation of the program in the clinical environment; and (6) pre- and post-implementation evaluation and ultimately program scale-up. The evaluation focuses on research activity and knowledge, attitudes and preferences about clinical research, evidence-based practice and leadership and post implementation, about their satisfaction with the program. The investigators will evaluate the feasibility and effect of the program according to capacity building measures and will revise where appropriate prior to scale-up. It is anticipated that this clinical research engagement and leadership capacity building program will enable and enhance clinically relevant research to be led and conducted by health professionals in the health setting. This approach will also encourage identification of areas of clinical uncertainty and need that can be addressed through clinical research within the health setting.
Passive fire building protection system evaluation (case study: millennium ict centre)
NASA Astrophysics Data System (ADS)
Rahman, Vinky; Stephanie
2018-03-01
Passive fire protection system is a system that refers to the building design, both regarding of architecture and structure. This system usually consists of structural protection that protects the structure of the building and prevents the spread of fire and facilitate the evacuation process in case of fire. Millennium ICT Center is the largest electronic shopping center in Medan, Indonesia. As a public building that accommodates the crowd, this building needs a fire protection system by the standards. Therefore, the purpose of this study is to evaluate passive fire protection system of Millennium ICT Center building. The study was conducted to describe the facts of the building as well as direct observation to the research location. The collected data is then processed using the AHP (Analytical Hierarchy Process) method in its weighting process to obtain the reliability value of passive fire protection fire system. The results showed that there are some components of passive fire protection system in the building, but some are still unqualified. The first section in your paper
An actuarial approach to retrofit savings in buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Subbarao, Krishnappa; Etingov, Pavel V.; Reddy, T. A.
An actuarial method has been developed for determining energy savings from retrofits from energy use data for a number of buildings. This method should be contrasted with the traditional method of using pre- and post-retrofit data on the same building. This method supports the U.S. Department of Energy Building Performance Database of real building performance data and related tools that enable engineering and financial practitioners to evaluate retrofits. The actuarial approach derives, from the database, probability density functions (PDFs) for energy savings from retrofits by creating peer groups for the user’s pre post buildings. From the energy use distribution ofmore » the two groups, the savings PDF is derived. This provides the basis for engineering analysis as well as financial risk analysis leading to investment decisions. Several technical issues are addressed: The savings PDF is obtained from the pre- and post-PDF through a convolution. Smoothing using kernel density estimation is applied to make the PDF more realistic. The low data density problem can be mitigated through a neighborhood methodology. Correlations between pre and post buildings are addressed to improve the savings PDF. Sample size effects are addressed through the Kolmogorov--Smirnov tests and quantile-quantile plots.« less
Commercial Building Energy Asset Score System: Program Overview and Technical Protocol (Version 1.0)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Na; Gorrissen, Willy J.
2013-01-11
The U.S. Department of Energy (DOE) is developing a national voluntary energy asset score system that includes an energy asset score tool to help building owners evaluate their buildings with respect to the score system. The goal of the energy asset score system is to facilitate cost-effective investment in energy efficiency improvements of commercial buildings. The system will allow building owners and managers to compare their building infrastructure against peers and track building upgrade progress over time. The system can also help other building stakeholders (e.g., building operators, tenants, financiers, and appraisers) understand the relative efficiency of different buildings inmore » a way that is independent from their operations and occupancy. This report outlines the technical protocol used to generate the energy asset score, explains the scoring methodology, and provides additional details regarding the energy asset score tool. This report also describes alternative methods that were considered prior to developing the current approach. Finally, this report describes a few features of the program where alternative approaches are still under evaluation.« less
Fusion of monocular cues to detect man-made structures in aerial imagery
NASA Technical Reports Server (NTRS)
Shufelt, Jefferey; Mckeown, David M.
1991-01-01
The extraction of buildings from aerial imagery is a complex problem for automated computer vision. It requires locating regions in a scene that possess properties distinguishing them as man-made objects as opposed to naturally occurring terrain features. It is reasonable to assume that no single detection method can correctly delineate or verify buildings in every scene. A cooperative-methods paradigm is useful in approaching the building extraction problem. Using this paradigm, each extraction technique provides information which can be added or assimilated into an overall interpretation of the scene. Thus, the main objective is to explore the development of computer vision system that integrates the results of various scene analysis techniques into an accurate and robust interpretation of the underlying three dimensional scene. The problem of building hypothesis fusion in aerial imagery is discussed. Building extraction techniques are briefly surveyed, including four building extraction, verification, and clustering systems. A method for fusing the symbolic data generated by these systems is described, and applied to monocular image and stereo image data sets. Evaluation methods for the fusion results are described, and the fusion results are analyzed using these methods.
ERIC Educational Resources Information Center
Moore, Corey L.; Manyibe, Edward O.; Aref, Fariborz; Washington, Andre L.
2017-01-01
Purpose: To evaluate a peer-to-peer mentor research team model (PPMRTM) in building investigators' research skills (i.e., research methods and grant writing) at a historically Black college/university (HBCU) in the United States. Method: Three different theories (i.e., planned change, critical mass, and self-efficacy), contemporary study findings,…
Formative Qualitative Evaluation for "Exploratory" ITS Research.
ERIC Educational Resources Information Center
Murray, Tom
1993-01-01
Discusses evaluation methods applicable to exploratory research areas, provides an overview of qualitative and formative methods for exploratory research on intelligent tutoring systems (ITS) and describes an exploratory study in ITS knowledge acquisition which involved working with three educators to build an ITS for high school physics.…
Davidson, Pamela L; Maccalla, Nicole M G; Afifi, Abdelmonem A; Guerrero, Lourdes; Nakazono, Terry T; Zhong, Shujin; Wallace, Steven P
2017-01-01
The National Institutes of Health (NIH) funds training programs to increase the numbers and skills of scientists who obtain NIH research grants, but few programs have been rigorously evaluated. The sizeable recent NIH investment in developing programs to increase the diversity of the NIH-funded workforce, implemented through the Diversity Program Consortium (DPC), is unusual in that it also funds a Consortium-wide evaluation plan, which spans the activities of the 10 BUilding Infrastructure Leading to Diversity (BUILD) awardees and the National Research Mentoring Network (NRMN). The purpose of this article is to describe the evaluation design and innovations of the BUILD Program on students, faculty, and institutions of the 10 primarily undergraduate BUILD sites. Our approach to this multi-methods quasi-experimental longitudinal evaluation emphasizes stakeholder participation and collaboration. The evaluation plan specifies the major evaluation questions and key short- to long-term outcome measures (or Hallmarks of Success). The Coordination and Evaluation Center (CEC) embarked on a comprehensive evaluation strategy by developing a set of logic models that incorporate the Hallmarks of Success and other outcomes that were collaboratively identified by the DPC. Data were collected from each BUILD site through national surveys from the Higher Education Research Institute at UCLA (HERI), annual followup surveys that align with the HERI instruments, site visits and case studies, program encounter data ("tracker" data), and institutional data. The analytic approach involves comparing changes in Hallmarks (key outcomes) within institutions for biomedical students who participated versus those who did not participate in the BUILD program at each institution, as well as between institution patterns of biomedical students at the BUILD sites, and matched institutions that were not BUILD grantees. Case studies provide insights into the institutionalization of these new programs and help to explain the processes that lead to the observed outcomes. Ultimately, the results of the consortium-wide evaluation will be used to inform national policy in higher education and will provide relevant examples of institutional and educational programmatic changes required to diversify the biomedical workforce in the USA.
Evaluating a physician leadership development program - a mixed methods approach.
Throgmorton, Cheryl; Mitchell, Trey; Morley, Tom; Snyder, Marijo
2016-05-16
Purpose - With the extent of change in healthcare today, organizations need strong physician leaders. To compensate for the lack of physician leadership education, many organizations are sending physicians to external leadership programs or developing in-house leadership programs targeted specifically to physicians. The purpose of this paper is to outline the evaluation strategy and outcomes of the inaugural year of a Physician Leadership Academy (PLA) developed and implemented at a Michigan-based regional healthcare system. Design/methodology/approach - The authors applied the theoretical framework of Kirkpatrick's four levels of evaluation and used surveys, observations, activity tracking, and interviews to evaluate the program outcomes. The authors applied grounded theory techniques to the interview data. Findings - The program met targeted outcomes across all four levels of evaluation. Interview themes focused on the significance of increasing self-awareness, building relationships, applying new skills, and building confidence. Research limitations/implications - While only one example, this study illustrates the importance of developing the evaluation strategy as part of the program design. Qualitative research methods, often lacking from learning evaluation design, uncover rich themes of impact. The study supports how a PLA program can enhance physician learning, engagement, and relationship building throughout and after the program. Physician leaders' partnership with organization development and learning professionals yield results with impact to individuals, groups, and the organization. Originality/value - Few studies provide an in-depth review of evaluation methods and outcomes of physician leadership development programs. Healthcare organizations seeking to develop similar in-house programs may benefit applying the evaluation strategy outlined in this study.
NASA Astrophysics Data System (ADS)
Ghaffarian, S.; Ghaffarian, S.
2014-08-01
This paper presents a novel approach to detect the buildings by automization of the training area collecting stage for supervised classification. The method based on the fact that a 3d building structure should cast a shadow under suitable imaging conditions. Therefore, the methodology begins with the detection and masking out the shadow areas using luminance component of the LAB color space, which indicates the lightness of the image, and a novel double thresholding technique. Further, the training areas for supervised classification are selected by automatically determining a buffer zone on each building whose shadow is detected by using the shadow shape and the sun illumination direction. Thereafter, by calculating the statistic values of each buffer zone which is collected from the building areas the Improved Parallelepiped Supervised Classification is executed to detect the buildings. Standard deviation thresholding applied to the Parallelepiped classification method to improve its accuracy. Finally, simple morphological operations conducted for releasing the noises and increasing the accuracy of the results. The experiments were performed on set of high resolution Google Earth images. The performance of the proposed approach was assessed by comparing the results of the proposed approach with the reference data by using well-known quality measurements (Precision, Recall and F1-score) to evaluate the pixel-based and object-based performances of the proposed approach. Evaluation of the results illustrates that buildings detected from dense and suburban districts with divers characteristics and color combinations using our proposed method have 88.4 % and 853 % overall pixel-based and object-based precision performances, respectively.
A method for building evaluation competency among community-based organizations.
Kelly, Cheryl M; LaRose, Jessi; Scharff, Darcell P
2014-05-01
Community-based organizations often lack the capacity (e.g., time, staff, skills) to effectively evaluate programs, policies, and environmental changes. Providing evaluation technical assistance and training can be an effective and feasible way to build individual evaluation competency. The purpose of this article is to present a practical approach and related tools that can be used by evaluators and others (e.g., academic partners, funders) providing assistance to build evaluation skills in community organizations. The approach described was developed in collaboration with local universities and a regional health foundation to provide intensive technical support to 19 community-based organizations awarded funding to implement obesity prevention projects. Technical assistance processes and tools were designed to be tailored to organizations' capacity and needs and can be used as templates by others who provide technical assistance. Evaluators, funders, and academic partners can use lessons learned from this experience to help shape and implement evaluation technical assistance approaches with community-based organizations.
Hou, Bin; Wang, Yunhong; Liu, Qingjie
2016-01-01
Characterizations of up to date information of the Earth’s surface are an important application providing insights to urban planning, resources monitoring and environmental studies. A large number of change detection (CD) methods have been developed to solve them by utilizing remote sensing (RS) images. The advent of high resolution (HR) remote sensing images further provides challenges to traditional CD methods and opportunities to object-based CD methods. While several kinds of geospatial objects are recognized, this manuscript mainly focuses on buildings. Specifically, we propose a novel automatic approach combining pixel-based strategies with object-based ones for detecting building changes with HR remote sensing images. A multiresolution contextual morphological transformation called extended morphological attribute profiles (EMAPs) allows the extraction of geometrical features related to the structures within the scene at different scales. Pixel-based post-classification is executed on EMAPs using hierarchical fuzzy clustering. Subsequently, the hierarchical fuzzy frequency vector histograms are formed based on the image-objects acquired by simple linear iterative clustering (SLIC) segmentation. Then, saliency and morphological building index (MBI) extracted on difference images are used to generate a pseudo training set. Ultimately, object-based semi-supervised classification is implemented on this training set by applying random forest (RF). Most of the important changes are detected by the proposed method in our experiments. This study was checked for effectiveness using visual evaluation and numerical evaluation. PMID:27618903
Hou, Bin; Wang, Yunhong; Liu, Qingjie
2016-08-27
Characterizations of up to date information of the Earth's surface are an important application providing insights to urban planning, resources monitoring and environmental studies. A large number of change detection (CD) methods have been developed to solve them by utilizing remote sensing (RS) images. The advent of high resolution (HR) remote sensing images further provides challenges to traditional CD methods and opportunities to object-based CD methods. While several kinds of geospatial objects are recognized, this manuscript mainly focuses on buildings. Specifically, we propose a novel automatic approach combining pixel-based strategies with object-based ones for detecting building changes with HR remote sensing images. A multiresolution contextual morphological transformation called extended morphological attribute profiles (EMAPs) allows the extraction of geometrical features related to the structures within the scene at different scales. Pixel-based post-classification is executed on EMAPs using hierarchical fuzzy clustering. Subsequently, the hierarchical fuzzy frequency vector histograms are formed based on the image-objects acquired by simple linear iterative clustering (SLIC) segmentation. Then, saliency and morphological building index (MBI) extracted on difference images are used to generate a pseudo training set. Ultimately, object-based semi-supervised classification is implemented on this training set by applying random forest (RF). Most of the important changes are detected by the proposed method in our experiments. This study was checked for effectiveness using visual evaluation and numerical evaluation.
Building Leadership Talent through Performance Evaluation
ERIC Educational Resources Information Center
Clifford, Matthew
2015-01-01
Most states and districts scramble to provide professional development to support principals, but "principal evaluation" is often lost amid competing priorities. Evaluation is an important method for supporting principal growth, communicating performance expectations to principals, and improving leadership practice. It provides leaders…
Zhiyong Cai; Michael O. Hunt; Robert J. Ross; Lawrence A. Soltis
1999-01-01
To date, there is no standard method for evaluating the structural integrity of wood floor systems using nondestructive techniques. Current methods of examination and assessment are often subjective and therefore tend to yield imprecise or variable results. For this reason, estimates of allowable wood floor loads are often conservative. The assignment of conservatively...
A proposal for seismic evaluation index of mid-rise existing RC buildings in Afghanistan
NASA Astrophysics Data System (ADS)
Naqi, Ahmad; Saito, Taiki
2017-10-01
Mid-rise RC buildings gradually rise in Kabul and entire Afghanistan since 2001 due to rapid increase of population. To protect the safety of resident, Afghan Structure Code was issued in 2012. But the building constructed before 2012 failed to conform the code requirements. In Japan, new sets of rules and law for seismic design of buildings had been issued in 1981 and severe earthquake damage was disclosed for the buildings designed before 1981. Hence, the Standard for Seismic Evaluation of RC Building published in 1977 has been widely used in Japan to evaluate the seismic capacity of existing buildings designed before 1981. Currently similar problem existed in Afghanistan, therefore, this research examined the seismic capacity of six RC buildings which were built before 2012 in Kabul by applying the seismic screening procedure presented by Japanese standard. Among three screening procedures with different capability, the less detailed screening procedure, the first level of screening, is applied. The study founds an average seismic index (IS-average=0.21) of target buildings. Then, the results were compared with those of more accurate seismic evaluation procedures of Capacity Spectrum Method (CSM) and Time History Analysis (THA). The results for CSM and THA show poor seismic performance of target buildings not able to satisfy the safety design limit (1/100) of the maximum story drift. The target buildings are then improved by installing RC shear walls. The seismic indices of these retrofitted buildings were recalculated and the maximum story drifts were analyzed by CSM and THA. The seismic indices and CSM and THA results are compared and found that building with seismic index larger than (IS-average =0.4) are able to satisfy the safety design limit. Finally, to screen and minimize the earthquake damage over the existing buildings, the judgement seismic index (IS-Judgment=0.5) for the first level of screening is proposed.
Is Passive or Active House Needed In Face of Global Warming?
NASA Astrophysics Data System (ADS)
Tamosaitis, Romualdas
2017-10-01
The article aims to determine how effective the stricter current requirements for the building envelope insolation are from the economic energy savings perspective. The article deals with a mathematical method for economic assessment of optimal building thermal insulation. The mathematical methods used in this article are based on evaluating the break-even point between the construction expenditures and the economic profit. Recent research shows that energy savings achieved solely through stricter standards applied to the building envelopes are limited in their ability to achieve maximum results. As the ratio of building volume to building envelope increases, further energy saving measures applied to the building envelope produce lower energy saving effects. Energy savings achieved using renewable energy resources, recuperation systems are much more effective. Research shows that much greater effect can be achieved by combining optimal building envelope energy efficiency measures with new requirements related to renewable energy sources and recuperating systems, such as solar batteries, wind turbines or heat pumps.
NASA Astrophysics Data System (ADS)
Li, Shuang; Yu, Xiaohui; Zhang, Yanjuan; Zhai, Changhai
2018-01-01
Casualty prediction in a building during earthquakes benefits to implement the economic loss estimation in the performance-based earthquake engineering methodology. Although after-earthquake observations reveal that the evacuation has effects on the quantity of occupant casualties during earthquakes, few current studies consider occupant movements in the building in casualty prediction procedures. To bridge this knowledge gap, a numerical simulation method using refined cellular automata model is presented, which can describe various occupant dynamic behaviors and building dimensions. The simulation on the occupant evacuation is verified by a recorded evacuation process from a school classroom in real-life 2013 Ya'an earthquake in China. The occupant casualties in the building under earthquakes are evaluated by coupling the building collapse process simulation by finite element method, the occupant evacuation simulation, and the casualty occurrence criteria with time and space synchronization. A case study of casualty prediction in a building during an earthquake is provided to demonstrate the effect of occupant movements on casualty prediction.
Rodgers, J.E.; Elebi, M.
2011-01-01
The 1994 Northridge earthquake caused brittle fractures in steel moment frame building connections, despite causing little visible building damage in most cases. Future strong earthquakes are likely to cause similar damage to the many un-retrofitted pre-Northridge buildings in the western US and elsewhere. Without obvious permanent building deformation, costly intrusive inspections are currently the only way to determine if major fracture damage that compromises building safety has occurred. Building instrumentation has the potential to provide engineers and owners with timely information on fracture occurrence. Structural dynamics theory predicts and scale model experiments have demonstrated that sudden, large changes in structure properties caused by moment connection fractures will cause transient dynamic response. A method is proposed for detecting the building-wide level of connection fracture damage, based on observing high-frequency, fracture-induced transient dynamic responses in strong motion accelerograms. High-frequency transients are short (<1 s), sudden-onset waveforms with frequency content above 25 Hz that are visually apparent in recorded accelerations. Strong motion data and damage information from intrusive inspections collected from 24 sparsely instrumented buildings following the 1994 Northridge earthquake are used to evaluate the proposed method. The method's overall success rate for this data set is 67%, but this rate varies significantly with damage level. The method performs reasonably well in detecting significant fracture damage and in identifying cases with no damage, but fails in cases with few fractures. Combining the method with other damage indicators and removing records with excessive noise improves the ability to detect the level of damage. ?? 2010 Elsevier B.V. All rights reserved.
Modal mass estimation from ambient vibrations measurement: A method for civil buildings
NASA Astrophysics Data System (ADS)
Acunzo, G.; Fiorini, N.; Mori, F.; Spina, D.
2018-01-01
A new method for estimating the modal mass ratios of buildings from unscaled mode shapes identified from ambient vibrations is presented. The method is based on the Multi Rigid Polygons (MRP) model in which each floor of the building is ideally divided in several non-deformable polygons that move independent of each other. The whole mass of the building is concentrated in the centroid of the polygons and the experimental mode shapes are expressed in term of rigid translations and of rotations. In this way, the mass matrix of the building can be easily computed on the basis of simple information about the geometry and the materials of the structure. The modal mass ratios can be then obtained through the classical equation of structural dynamics. Ambient vibrations measurement must be performed according to this MRP models, using at least two biaxial accelerometers per polygon. After a brief illustration of the theoretical background of the method, numerical validations are presented analysing the method sensitivity for possible different source of errors. Quality indexes are defined for evaluating the approximation of the modal mass ratios obtained from a certain MRP model. The capability of the proposed model to be applied to real buildings is illustrated through two experimental applications. In the first one, a geometrically irregular reinforced concrete building is considered, using a calibrated Finite Element Model for validating the results of the method. The second application refers to a historical monumental masonry building, with a more complex geometry and with less information available. In both cases, MRP models with a different number of rigid polygons per floor are compared.
Anthrax Sampling and Decontamination: Technology Trade-Offs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Price, Phillip N.; Hamachi, Kristina; McWilliams, Jennifer
2008-09-12
The goal of this project was to answer the following questions concerning response to a future anthrax release (or suspected release) in a building: 1. Based on past experience, what rules of thumb can be determined concerning: (a) the amount of sampling that may be needed to determine the extent of contamination within a given building; (b) what portions of a building should be sampled; (c) the cost per square foot to decontaminate a given type of building using a given method; (d) the time required to prepare for, and perform, decontamination; (e) the effectiveness of a given decontamination methodmore » in a given type of building? 2. Based on past experience, what resources will be spent on evaluating the extent of contamination, performing decontamination, and assessing the effectiveness of the decontamination in abuilding of a given type and size? 3. What are the trade-offs between cost, time, and effectiveness for the various sampling plans, sampling methods, and decontamination methods that have been used in the past?« less
Post occupancy evaluation of energy-efficient behavior in informal housing of high density area
NASA Astrophysics Data System (ADS)
Aulia, D. N.; Marpaung, B. O. Y.
2018-02-01
The concept of energy-efficient building emphasizes the critical of efficiency in the use of water, electrical energy, and building materials, beginning with design, construction, to the maintenance of the building in the future. This study was conducted to observe the behavior of Energy Saving of the residents in performing everyday activities in the building. The observed variables are the consumption of natural resources (energy, material, water, and land) and the emissions of air, water, and land related to the environment and health. This research is a descriptive qualitative research with the method of data collection is the distribution of questionnaires and observation. The method of analyzing data is posted occupancy evaluation undertaken to obtain patterns of community-based behavior in urban areas. The informal high-density housing area is a typology of population settlements that found in many big cities in Indonesia. This community represents various community groups regarding occupation, education, income, and race. The results of the study concluded that there are five components of energy-saving behavioral formers in housing namely: residential building components, environmental components in occupancy, external occupancy components, components of social activities and elements of business
Automatic building extraction from LiDAR data fusion of point and grid-based features
NASA Astrophysics Data System (ADS)
Du, Shouji; Zhang, Yunsheng; Zou, Zhengrong; Xu, Shenghua; He, Xue; Chen, Siyang
2017-08-01
This paper proposes a method for extracting buildings from LiDAR point cloud data by combining point-based and grid-based features. To accurately discriminate buildings from vegetation, a point feature based on the variance of normal vectors is proposed. For a robust building extraction, a graph cuts algorithm is employed to combine the used features and consider the neighbor contexture information. As grid feature computing and a graph cuts algorithm are performed on a grid structure, a feature-retained DSM interpolation method is proposed in this paper. The proposed method is validated by the benchmark ISPRS Test Project on Urban Classification and 3D Building Reconstruction and compared to the state-art-of-the methods. The evaluation shows that the proposed method can obtain a promising result both at area-level and at object-level. The method is further applied to the entire ISPRS dataset and to a real dataset of the Wuhan City. The results show a completeness of 94.9% and a correctness of 92.2% at the per-area level for the former dataset and a completeness of 94.4% and a correctness of 95.8% for the latter one. The proposed method has a good potential for large-size LiDAR data.
Comprehensive benefits analysis of steel structure modular residence based on the entropy evaluation
NASA Astrophysics Data System (ADS)
Zhang, Xiaoxiao; Wang, Li; Jiang, Pengming
2017-04-01
Steel structure modular residence is the outstanding residential industrialization. It has many advantages, such as the low whole cost, high resource recovery, a high degree of industrialization. This paper compares the comprehensive benefits of steel structural in modular buildings with prefabricated reinforced concrete residential from economic benefits, environmental benefits, social benefits and technical benefits by the method of entropy evaluation. Finally, it is concluded that the comprehensive benefits of steel structural in modular buildings is better than that of prefabricated reinforced concrete residential. The conclusion of this study will provide certain reference significance to the development of steel structural in modular buildings in China.
A protocol for lifetime energy and environmental impact assessment of building insulation materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shrestha, Som S., E-mail: shresthass@ornl.gov; Biswas, Kaushik; Desjarlais, Andre O.
This article describes a proposed protocol that is intended to provide a comprehensive list of factors to be considered in evaluating the direct and indirect environmental impacts of building insulation materials, as well as detailed descriptions of standardized calculation methodologies to determine those impacts. The energy and environmental impacts of insulation materials can generally be divided into two categories: (1) direct impact due to the embodied energy of the insulation materials and other factors and (2) indirect or environmental impacts avoided as a result of reduced building energy use due to addition of insulation. Standards and product category rules exist,more » which provide guidelines about the life cycle assessment (LCA) of materials, including building insulation products. However, critical reviews have suggested that these standards fail to provide complete guidance to LCA studies and suffer from ambiguities regarding the determination of the environmental impacts of building insulation and other products. The focus of the assessment protocol described here is to identify all factors that contribute to the total energy and environmental impacts of different building insulation products and, more importantly, provide standardized determination methods that will allow comparison of different insulation material types. Further, the intent is not to replace current LCA standards but to provide a well-defined, easy-to-use comparison method for insulation materials using existing LCA guidelines. - Highlights: • We proposed a protocol to evaluate the environmental impacts of insulation materials. • The protocol considers all life cycle stages of an insulation material. • Both the direct environmental impacts and the indirect impacts are defined. • Standardized calculation methods for the ‘avoided operational energy’ is defined. • Standardized calculation methods for the ‘avoided environmental impact’ is defined.« less
Espinet, Stacey; Naqvi, Reza; Lingard, Lorelei; Steele, Margaret
2018-01-01
Introduction The need for child/adolescent mental health care in Canada is growing. Primary care can play a key role in filling this gap, yet most providers feel they do not have adequate training. This paper reviews the Canadian literature on capacity building programs in child and adolescent psychiatry for primary care providers, to examine how these programs are being implemented and evaluated to contribute to evidence-based initiatives. Methods A systematic literature review of peer-reviewed published articles of capacity building initiatives in child/adolescent mental health care for primary care practitioners that have been implemented in Canada. Results Sixteen articles were identified that met inclusion criteria. Analysis revealed that capacity building initiatives in Canada are varied but rigorous evaluation methodology is lacking. Primary care providers welcome efforts to increase mental health care capacity and were satisfied with the implementation of most programs. Discussion Objective conclusions regarding the effectiveness of these programs to increase mental health care capacity is challenging given the evaluation methodology of these studies. Conclusion Rigorous evaluation methods are needed to make evidence-based decisions on ways forward to be able to build child/adolescent mental health care capacity in primary care. Outcome measures need to move beyond self-report to more objective measures, and should expand the measurement of patient outcomes to ensure that these initiative are indeed leading to improved care for families. PMID:29662521
ERIC Educational Resources Information Center
Morse, Emile L.; Schmidt, Heidi; Butter, Karen; Rider, Cynthia; Hickey, Thomas B.; O'Neill, Edward T.; Toves, Jenny; Green, Marlan; Soy, Sue; Gunn, Stan; Galloway, Patricia
2002-01-01
Includes four articles that discuss evaluation methods for information management systems under the Defense Advanced Research Projects Agency; building digital libraries at the University of California San Francisco's Tobacco Control Archives; IFLA's Functional Requirements for Bibliographic Records; and designing the Texas email repository model…
NASA Astrophysics Data System (ADS)
Mola Ebrahimi, S.; Arefi, H.; Rasti Veis, H.
2017-09-01
Our paper aims to present a new approach to identify and extract building footprints using aerial images and LiDAR data. Employing an edge detector algorithm, our method first extracts the outer boundary of buildings, and then by taking advantage of Hough transform and extracting the boundary of connected buildings in a building block, it extracts building footprints located in each block. The proposed method first recognizes the predominant leading orientation of a building block using Hough transform, and then rotates the block according to the inverted complement of the dominant line's angle. Therefore the block poses horizontally. Afterwards, by use of another Hough transform, vertical lines, which might be the building boundaries of interest, are extracted and the final building footprints within a block are obtained. The proposed algorithm is implemented and tested on the urban area of Zeebruges, Belgium(IEEE Contest,2015). The areas of extracted footprints are compared to the corresponding areas in the reference data and mean error is equal to 7.43 m2. Besides, qualitative and quantitative evaluations suggest that the proposed algorithm leads to acceptable results in automated precise extraction of building footprints.
Method for Evaluating Energy Use of Dishwashers, Clothes Washers, and Clothes Dryers: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eastment, M.; Hendron, R.
Building America teams are researching opportunities to improve energy efficiency for some of the more challenging end-uses, such as lighting (both fixed and occupant-provided), appliances (clothes washer, dishwasher, clothes dryer, refrigerator, and range), and miscellaneous electric loads, which are all heavily dependent on occupant behavior and product choices. These end-uses have grown to be a much more significant fraction of total household energy use (as much as 50% for very efficient homes) as energy efficient homes have become more commonplace through programs such as ENERGY STAR and Building America. As modern appliances become more sophisticated the residential energy analyst ismore » faced with a daunting task in trying to calculate the energy savings of high efficiency appliances. Unfortunately, most whole-building simulation tools do not allow the input of detailed appliance specifications. Using DOE test procedures the method outlined in this paper presents a reasonable way to generate inputs for whole-building energy-simulation tools. The information necessary to generate these inputs is available on Energy-Guide labels, the ENERGY-STAR website, California Energy Commission's Appliance website and manufacturer's literature. Building America has developed a standard method for analyzing the effect of high efficiency appliances on whole-building energy consumption when compared to the Building America's Research Benchmark building.« less
Advanced Extended Plate and Beam Wall System in a Cold-Climate House
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mallay, Dave; Wiehagen, Joseph; Kochkin, Vladimir
This report presents the design and evaluation of an innovative wall system. This highly insulated (high-R) light-frame wall system for use above grade in residential buildings is referred to as Extended Plate & Beam (EP&B). The EP&B design is the first of its kind to be featured in a new construction test house (NCTH) for the DOE Building America program. The EP&B wall design integrates standard building methods and common building products to construct a high-R wall that minimizes transition risks and costs to builders.
NASA Astrophysics Data System (ADS)
Jeon, Hosang; Nam, Jiho; Lee, Jayoung; Park, Dahl; Baek, Cheol-Ha; Kim, Wontaek; Ki, Yongkan; Kim, Dongwon
2015-06-01
Accurate dose delivery is crucial to the success of modern radiotherapy. To evaluate the dose actually delivered to patients, in-vivo dosimetry (IVD) is generally performed during radiotherapy to measure the entrance doses. In IVD, a build-up device should be placed on top of an in-vivo dosimeter to satisfy the electron equilibrium condition. However, a build-up device made of tissue-equivalent material or metal may perturb dose delivery to a patient, and requires an additional laborious and time-consuming process. We developed a novel IVD method using a look-up table of conversion ratios instead of a build-up device. We validated this method through a monte-carlo simulation and 31 clinical trials. The mean error of clinical IVD is 3.17% (standard deviation: 2.58%), which is comparable to that of conventional IVD methods. Moreover, the required time was greatly reduced so that the efficiency of IVD could be improved for both patients and therapists.
Building clinical networks: a developmental evaluation framework.
Carswell, Peter; Manning, Benjamin; Long, Janet; Braithwaite, Jeffrey
2014-05-01
Clinical networks have been designed as a cross-organisational mechanism to plan and deliver health services. With recent concerns about the effectiveness of these structures, it is timely to consider an evidence-informed approach for how they can be developed and evaluated. To document an evaluation framework for clinical networks by drawing on the network evaluation literature and a 5-year study of clinical networks. We searched literature in three domains: network evaluation, factors that aid or inhibit network development, and on robust methods to measure network characteristics. This material was used to build a framework required for effective developmental evaluation. The framework's architecture identifies three stages of clinical network development; partner selection, network design and network management. Within each stage is evidence about factors that act as facilitators and barriers to network growth. These factors can be used to measure progress via appropriate methods and tools. The framework can provide for network growth and support informed decisions about progress. For the first time in one place a framework incorporating rigorous methods and tools can identify factors known to affect the development of clinical networks. The target user group is internal stakeholders who need to conduct developmental evaluation to inform key decisions along their network's developmental pathway.
Evaluation of the Development of Professional Competence in Undergraduates: Methodical Aspects
ERIC Educational Resources Information Center
Leontyev, Vyacheslav V.; Rebrina, Fayruza G.; Leontyeva, Irina A.; Gafiyatullina, Elvira A.
2016-01-01
Bologna process puts in a high claim for the modern European education in terms of competency building approach. The control is conducted by the agencies which monitor learning activity level in higher education institutions. This paper presents the aspects of higher education within the conduction of competency building approach projects in…
ERIC Educational Resources Information Center
Morris, Michael Lane; Storberg-Walker, Julia; McMillan, Heather S.
2009-01-01
This article presents a new model, generated through applied theory-building research methods, that helps human resource development (HRD) practitioners evaluate the return on investment (ROI) of organization development (OD) interventions. This model, called organization development human-capital accounting system (ODHCAS), identifies…
NASA Astrophysics Data System (ADS)
Szafranko, E.
2017-08-01
When planning a building structure, dilemmas arise as to what construction and material solutions are feasible. The decisions are not always obvious. A procedure for selecting the variant that will best satisfy the expectations of the investor and future users of a structure must be founded on mathematical methods. The following deserve special attention: the MCE methods, Hierarchical Analysis Methods and Weighting Methods. Another interesting solution, particularly useful when dealing with evaluations which take into account negative values, is the Indicator Method. MCE methods are relatively popular owing to the simplicity of the calculations and ease of the interpretation of the results. Having prepared the input data properly, they enable the user to compare them on the same level. In a situation where an analysis involves a large number of data, it is more convenient to divide them into groups according to main criteria and subcriteria. This option is provided by hierarchical analysis methods. They are based on ordered sets of criteria, which are evaluated in groups. In some cases, this approach yields the results that are superior and easier to read. If an analysis encompasses direct and indirect effects, an Indicator Method seems to be a justified choice for selecting the right solution. The Indicator Method is different in character and relies on weights and assessments of effects. It allows the user to evaluate effectively the analyzed variants. This article explains the methodology of conducting a multi-criteria analysis, showing its advantages and disadvantages. An example of calculations contained in the article shows what problems can be encountered when making an assessment of various solutions regarding building materials and structures. For comparison, an analysis based on graphical methods developed by the author was presented.
NASA Astrophysics Data System (ADS)
Potekhin, Igor; Mischenko, Valeryi; Mottaeva, Angela; Zheltenkov, Alexander
2018-03-01
In this article explained approach of valuation of intellectual property of Voronezh State Technical University, as her usefulness to increasing the sustainability and ecological safety of high-rise building. High-rise building is main type of buildings in modern cities. They include large volume of material mass, high volume of energy using and high volume of emissions. Using innovation solutions to improving ecology safety of high-rise buildings has large potential to city in whole. Explained in the article methods of calculation of effects helps to value sustainable solutions of present and future generations. Thus usefulness of patents express through usefulness regarding to high-rise building, including for sustainable development.
D'Orso, M I; Centemeri, R; Latocca, R; Riva, M; Cesana, G
2012-01-01
Occupational Health Doctors active in building sector firms frequently have to evaluate residual workers' osteomuscular function in patients coming back to work after an accident happened during work time or free time. Definition of their specific individual work suitability is usually carried out utilizing semeiotic tests in which subjective evaluation of every single Medical Doctor is real important in definition of final results and this fact can cause legal controversies. In our research we describe the application of computerised movement analysis on 10 workers of building sector. In every patient examined this technical method has been able to study objectively the tridimensional ranges of motion of most important osteomuscular districts. The possibility to have an objective evaluation of residual osteomuscular function has a relevant importance both in definition of workers' work suitability at the moment in which they start again their activities and in possible future legal conflicts.
23 CFR 636.304 - What process may be used to rate and score proposals?
Code of Federal Regulations, 2010 CFR
2010-04-01
... ENGINEERING AND TRAFFIC OPERATIONS DESIGN-BUILD CONTRACTING Proposal Evaluation Factors § 636.304 What process... any rating method or combination of methods including color or adjectival ratings, numerical weights...
Residual stress evaluation of components produced via direct metal laser sintering
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kemerling, Brandon; Lippold, John C.; Fancher, Christopher M.
Direct metal laser sintering is an additive manufacturing process which is capable of fabricating three-dimensional components using a laser energy source and metal powder particles. Despite the numerous benefits offered by this technology, the process maturity is low with respect to traditional subtractive manufacturing methods. Relationships between key processing parameters and final part properties are generally lacking and require further development. In this study, residual stresses were evaluated as a function of key process variables. The variables evaluated included laser scan strategy and build plate preheat temperature. Residual stresses were measured experimentally via neutron diffraction and computationally via finite elementmore » analysis. Good agreement was shown between the experimental and computational results. Results showed variations in the residual stress profile as a function of laser scan strategy. Compressive stresses were dominant along the build height (z) direction, and tensile stresses were dominant in the x and y directions. Build plate preheating was shown to be an effective method for alleviating residual stress due to the reduction in thermal gradient.« less
Residual stress evaluation of components produced via direct metal laser sintering
Kemerling, Brandon; Lippold, John C.; Fancher, Christopher M.; ...
2018-03-22
Direct metal laser sintering is an additive manufacturing process which is capable of fabricating three-dimensional components using a laser energy source and metal powder particles. Despite the numerous benefits offered by this technology, the process maturity is low with respect to traditional subtractive manufacturing methods. Relationships between key processing parameters and final part properties are generally lacking and require further development. In this study, residual stresses were evaluated as a function of key process variables. The variables evaluated included laser scan strategy and build plate preheat temperature. Residual stresses were measured experimentally via neutron diffraction and computationally via finite elementmore » analysis. Good agreement was shown between the experimental and computational results. Results showed variations in the residual stress profile as a function of laser scan strategy. Compressive stresses were dominant along the build height (z) direction, and tensile stresses were dominant in the x and y directions. Build plate preheating was shown to be an effective method for alleviating residual stress due to the reduction in thermal gradient.« less
Evaluation of Vacuum Blasting and Heat Guns as Methods for Abating Lead- Based Paint on Buildings
1993-09-01
INCOMPATIBILITY - Contact with powerful oxidizing agents such as FLUORINE, CHLORINE TRIFLUORIDE , MANGANESE TRIOXIDE, OXYGEN DIFLUORIDE, MANGANESE...investigating new technologies for lead-based paint abatement. This research evaluates the effectiveness , safety, LEC1L•.T• and cost of vacuum abrasive...paint abatement. This research evaluates the effectiveness , safety, and cost of vacuum abrasive units and heat guns as methods of removing lead-based
Information Science and Responsive Evaluation
ERIC Educational Resources Information Center
Stake, Robert E.
2014-01-01
Responsive evaluation builds upon the methods of informal evaluation in disciplined ways: getting personally acquainted with the evaluand, observation of activities, interviewing people who are in different ways familiar with the evaluand, searching documents that reveal what happened in the past or somewhere else. It calls for sustained effort to…
Thought leadership: A new indicator for national and institutional comparison
Klavans, Richard; Boyack, Kevin W.
2008-03-08
This article introduces a new method for evaluating national publication activities. This new indicator, thought leadership, captures whether the nation is a thought leader (building on the more recently cited literature for that field) or follower (building on the older cited literature for that field). Publication data for 2003 are used to illustrate which nations tend to build on the more recent discoveries in chemistry and clinical medicine. Finally, implications for national and laboratory policy are discussed.
Stakeholder-focused evaluation of an online course for health care providers.
Dunet, Diane O; Reyes, Michele
2006-01-01
Different people who have a stake or interest in a training course (stakeholders) may have markedly different definitions of what constitutes "training success" and how they will use evaluation results. Stakeholders at multiple levels within and outside of the organization guided the development of an evaluation plan for a Web-based training course on hemochromatosis. Stakeholder interests and values were reflected in the type, level, and rigor of evaluation methods selected. Our mixed-method evaluation design emphasized small sample sizes and repeated measures. Limited resources for evaluation were leveraged by focusing on the data needs of key stakeholders, understanding how they wanted to use evaluation results, and collecting data needed for stakeholder decision making. Regular feedback to key stakeholders provided opportunities for updating the course evaluation plan to meet emerging needs for new or different information. Early and repeated involvement of stakeholders in the evaluation process also helped build support for the final product. Involving patient advocacy groups, managers, and representative course participants improved the course and enhanced product dissemination. For training courses, evaluation planning is an opportunity to tailor methods and data collection to meet the information needs of particular stakeholders. Rigorous evaluation research of every training course may be infeasible or unwarranted; however, course evaluations can be improved by good planning. A stakeholder-focused approach can build a picture of the results and impact of training while fostering the practical use of evaluation data.
The Evaluation of Physical Learning Environments: A Critical Review of the Literature
ERIC Educational Resources Information Center
Cleveland, Benjamin; Fisher, Kenn
2014-01-01
This article critically reviews the methodologies and methods that have been used for the evaluation of physical learning environments. To contextualize discussion about the evaluation of learning spaces, we initially chart the development of post-occupancy evaluation (POE) for non-domestic buildings. We then discuss the recent evolution of POE…
NASA Astrophysics Data System (ADS)
Cunningham, Dara Suzanne
The way buildings are designed now, there is little feedback from use involved in the design process. Attempts to correct this problem have been made in the form of Post Occupancy Evaluations (POEs) for 50-years but have largely failed. POEs are the accepted method for environmental designers to collect feedback about buildings in use. They are infrequently conducted, after the building is built, in a one-time only evaluation, and not funded as part of the build process. Other products receive feedback about the design in use from online critiques. Online critiques could provide a platform for feedback from actors engaged with buildings in use for environmental designers to utilize in developing reflective design rationale to avoid adverse consequences in future designs or correct consequences in past and current designs. Since buildings constitute such a large part of the human environment, it's important to research the effects of buildings on their inhabitants. In order for environmental designers to act on feedback from situated use, designers need to have access to that feedback and all actors interacting with the building design need to have an easy, inexpensive, and accessible method to submit feedback. These needs can be addressed by utilizing modern networked and mobile computing to collect and access building feedback. The analysis presented in this dissertation is informed by a thorough evaluation of the theory of reflective practice, activity theory, environmental design, and cognitive science research. From this analysis, I developed the following contributions. First, I expanded Schon's reflective practice by combining his theory with a modified version of activity theory, using activity theory to enrich reflective practice and create Reflective Activity Systems Theory (RAST), which provides a new framework to develop design rationale based on feedback from use and a focus on the activity. Second, I suggest the design of an activity information system, Socio-Technical Environments for Evolutionary Design (STEED), which provides an interactive platform for actor and artifact feedback from the use situation. Third, I discuss implications for practice by discussing how the feedback from actors and artifacts in situated use can be used to create reflective design rationale.
NASA Astrophysics Data System (ADS)
Erener, A.
2013-04-01
Automatic extraction of urban features from high resolution satellite images is one of the main applications in remote sensing. It is useful for wide scale applications, namely: urban planning, urban mapping, disaster management, GIS (geographic information systems) updating, and military target detection. One common approach to detecting urban features from high resolution images is to use automatic classification methods. This paper has four main objectives with respect to detecting buildings. The first objective is to compare the performance of the most notable supervised classification algorithms, including the maximum likelihood classifier (MLC) and the support vector machine (SVM). In this experiment the primary consideration is the impact of kernel configuration on the performance of the SVM. The second objective of the study is to explore the suitability of integrating additional bands, namely first principal component (1st PC) and the intensity image, for original data for multi classification approaches. The performance evaluation of classification results is done using two different accuracy assessment methods: pixel based and object based approaches, which reflect the third aim of the study. The objective here is to demonstrate the differences in the evaluation of accuracies of classification methods. Considering consistency, the same set of ground truth data which is produced by labeling the building boundaries in the GIS environment is used for accuracy assessment. Lastly, the fourth aim is to experimentally evaluate variation in the accuracy of classifiers for six different real situations in order to identify the impact of spatial and spectral diversity on results. The method is applied to Quickbird images for various urban complexity levels, extending from simple to complex urban patterns. The simple surface type includes a regular urban area with low density and systematic buildings with brick rooftops. The complex surface type involves almost all kinds of challenges, such as high dense build up areas, regions with bare soil, and small and large buildings with different rooftops, such as concrete, brick, and metal. Using the pixel based accuracy assessment it was shown that the percent building detection (PBD) and quality percent (QP) of the MLC and SVM depend on the complexity and texture variation of the region. Generally, PBD values range between 70% and 90% for the MLC and SVM, respectively. No substantial improvements were observed when the SVM and MLC classifications were developed by the addition of more variables, instead of the use of only four bands. In the evaluation of object based accuracy assessment, it was demonstrated that while MLC and SVM provide higher rates of correct detection, they also provide higher rates of false alarms.
Evaluation of modal pushover-based scaling of one component of ground motion: Tall buildings
Kalkan, Erol; Chopra, Anil K.
2012-01-01
Nonlinear response history analysis (RHA) is now increasingly used for performance-based seismic design of tall buildings. Required for nonlinear RHAs is a set of ground motions selected and scaled appropriately so that analysis results would be accurate (unbiased) and efficient (having relatively small dispersion). This paper evaluates accuracy and efficiency of recently developed modal pushover–based scaling (MPS) method to scale ground motions for tall buildings. The procedure presented explicitly considers structural strength and is based on the standard intensity measure (IM) of spectral acceleration in a form convenient for evaluating existing structures or proposed designs for new structures. Based on results presented for two actual buildings (19 and 52 stories, respectively), it is demonstrated that the MPS procedure provided a highly accurate estimate of the engineering demand parameters (EDPs), accompanied by significantly reduced record-to-record variability of the responses. In addition, the MPS procedure is shown to be superior to the scaling procedure specified in the ASCE/SEI 7-05 document.
Cui, Borui; Gao, Dian-ce; Xiao, Fu; ...
2016-12-23
This article provides a method in comprehensive evaluation of cost-saving potential of active cool thermal energy storage (CTES) integrated with HVAC system for demand management in non-residential building. The active storage is beneficial by shifting peak demand for peak load management (PLM) as well as providing longer duration and larger capacity of demand response (DR). In this research, a model-based optimal design method using genetic algorithm is developed to optimize the capacity of active CTES aiming for maximizing the life-cycle cost saving concerning capital cost associated with storage capacity as well as incentives from both fast DR and PLM. Inmore » the method, the active CTES operates under a fast DR control strategy during DR events while under the storage-priority operation mode to shift peak demand during normal days. The optimal storage capacities, maximum annual net cost saving and corresponding power reduction set-points during DR event are obtained by using the proposed optimal design method. Lastly, this research provides guidance in comprehensive evaluation of cost-saving potential of CTES integrated with HVAC system for building demand management including both fast DR and PLM.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cui, Borui; Gao, Dian-ce; Xiao, Fu
This article provides a method in comprehensive evaluation of cost-saving potential of active cool thermal energy storage (CTES) integrated with HVAC system for demand management in non-residential building. The active storage is beneficial by shifting peak demand for peak load management (PLM) as well as providing longer duration and larger capacity of demand response (DR). In this research, a model-based optimal design method using genetic algorithm is developed to optimize the capacity of active CTES aiming for maximizing the life-cycle cost saving concerning capital cost associated with storage capacity as well as incentives from both fast DR and PLM. Inmore » the method, the active CTES operates under a fast DR control strategy during DR events while under the storage-priority operation mode to shift peak demand during normal days. The optimal storage capacities, maximum annual net cost saving and corresponding power reduction set-points during DR event are obtained by using the proposed optimal design method. Lastly, this research provides guidance in comprehensive evaluation of cost-saving potential of CTES integrated with HVAC system for building demand management including both fast DR and PLM.« less
NASA Astrophysics Data System (ADS)
Ghosh, Rahul; Debbarma, Rama
2017-06-01
Setback structures are highly vulnerable during earthquakes due to its vertical geometrical and mass irregularity, but the vulnerability becomes higher if the structures also have stiffness irregularity in elevation. The risk factor of such structure may increase, if the structure rests on sloping ground. In this paper, an attempt has been made to evaluate the seismic performance of setback structures resting on plain ground as well as in the slope of a hill, with soft storey configuration. The analysis has been performed in three individual methods, equivalent static force method, response spectrum method and time history method and extreme responses have been recorded for open ground storeyed setback building. To mitigate this soft storey effect and the extreme responses, three individual mitigation techniques have been adopted and the best solution among these three techniques is presented.
Samuel V. Glass; Stanley D. Gatland II; Kohta Ueno; Christopher J. Schumacher
2017-01-01
ASHRAE Standard 160, Criteria for Moisture-Control Design Analysis in Buildings, was published in 2009. The standard sets criteria for moisture design loads, hygrothermal analysis methods, and satisfactory moisture performance of the building envelope. One of the evaluation criteria specifies conditions necessary to avoid mold growth. The current standard requires that...
ERIC Educational Resources Information Center
Ylimaki, Rose M.; Brunderman, Lynnette; Bennett, Jeffrey V.; Dugan, Thad
2014-01-01
Today's accountability policies and changing demographics have created conditions in which leaders must rapidly build school capacity and improve outcomes in culturally diverse schools. This article presents findings from a mixed-methods evaluation of an Arizona Turnaround Leadership Development Project. The project drew on studies of turnaround…
Building and Solving Odd-One-Out Classification Problems: A Systematic Approach
ERIC Educational Resources Information Center
Ruiz, Philippe E.
2011-01-01
Classification problems ("find the odd-one-out") are frequently used as tests of inductive reasoning to evaluate human or animal intelligence. This paper introduces a systematic method for building the set of all possible classification problems, followed by a simple algorithm for solving the problems of the R-ASCM, a psychometric test derived…
NASA Astrophysics Data System (ADS)
Grzyl, Beata; Kristowski, Adam; Miszewska-Urbańska, Emilia
2017-10-01
Each investment plan, including the one concerning a building, is exposed to the consequences of various types of threats taking place. Therefore, in the case of some large-scale, atypical and complicated building ventures, some actions included in the procedure of risk management should be taken (identifications, analysis, measurements, control and supervision of the risk). This will allow for the risk to be eliminated or limited. While preparing a building venture, an investor does not possess full information about the course of events on each stage of investment completion. The identification of the above-mentioned unknowns, subjecting them to quantification and specifying the method of dealing with them, allows an investor to increase the effectiveness of the intended plan. The enterprise discussed in this article and analyzed in the context of risk, concerns alteration, revitalization and conversion for office purposes of two buildings located in Gdańsk at 1 and 2 Lastadia Street. These buildings are situated on the area of historical urban layout of Gdańsk, in the northern-eastern part of Stare Przedmieście District (Old Suburb), about 800 meters south from Dlugi Targ Street and 200 meters west from The Old Motława River. The investor is “Gdańskie Melioracje Ltd.”, a limited liability company, which belongs to the Council of Gdańsk. In order to increase the effectiveness of the intended investment venture, while organizing the investment process, the investor commissioned preparation of an analysis and risk evaluation connected with the above-mentioned intention. Based on an on-site visit, the opinions of experts, who have been involved in the process of the preparation of the investment, studies of the available monographies about the technical condition of the buildings at 1 and 2 Lastadia Street and their own experiences, the authors identified 54 types of relevant risks, which have been systematized into 10 subject groups (among others- investor’s risk due to the designing process, location of the investment, third party or investor business activity, force majeure, political, legal, financial, technical). The scope of the study includes the identification, analysis and risk evaluation connected with planning and completion of alteration, revitalization and conversion of a historic building located at 2 Lastadia Street for the office purposes. The risk has been analyzed from the investor’s perspective. The authors used a method of preliminary analysis and risk evaluation PHA (Preliminary Hazard Analysis) and the expert method.
A Program Evaluation of a Leadership Academy for School Principals
ERIC Educational Resources Information Center
Wagner, Kristi E.
2014-01-01
This program evaluation focused on mid-range outcomes of a leadership academy for school principals. The mixed-methods evaluation included interviews, principals' instructional observation database, and teacher surveys. The Principal Academy program was designed to build principals' knowledge of high-yield instructional strategies (Hattie, 2009),…
Economic aspects of possible residential heating conservation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hopkowicz, M.; Szul, A.
1995-12-31
The paper presents methods of evaluation of energy and economy related effects of different actions aimed at conservation in residential buildings. It identifies also the method of selecting the most effective way of distribution funds assigned to weatherization as well as necessary improvements to be implemented within the heating node and the internal heating system of the building. The analysis of data gathered for four 11-stories high residential buildings of {open_quotes}Zeran{close_quotes} type being subject of the Conservation Demonstrative Project, included a differentiated scope of weatherization efforts and various actions aimed at system upgrading. Basing upon the discussion of the splitmore » of heat losses in a building as well as the established energy savings for numerous options of upgrading works, the main problem has been defined. It consists in optimal distribution of financial means for the discussed measures if the total amount of funds assigned for modifications is defined. The method based upon the principle of relative increments has been suggested. The economical and energy specifications of the building and its components, required for this method have also been elaborated. The application of this method allowed to define the suggested optimal scope of actions within the entire fund assigned for the comprehensive weatherization.« less
Building Damage Assessment after Earthquake Using Post-Event LiDAR Data
NASA Astrophysics Data System (ADS)
Rastiveis, H.; Eslamizade, F.; Hosseini-Zirdoo, E.
2015-12-01
After an earthquake, damage assessment plays an important role in leading rescue team to help people and decrease the number of mortality. Damage map is a map that demonstrates collapsed buildings with their degree of damage. With this map, finding destructive buildings can be quickly possible. In this paper, we propose an algorithm for automatic damage map generation after an earthquake using post-event LiDAR Data and pre-event vector map. The framework of the proposed approach has four main steps. To find the location of all buildings on LiDAR data, in the first step, LiDAR data and vector map are registered by using a few number of ground control points. Then, building layer, selected from vector map, are mapped on the LiDAR data and all pixels which belong to the buildings are extracted. After that, through a powerful classifier all the extracted pixels are classified into three classes of "debris", "intact building" and "unclassified". Since textural information make better difference between "debris" and "intact building" classes, different textural features are applied during the classification. After that, damage degree for each candidate building is estimated based on the relation between the numbers of pixels labelled as "debris" class to the whole building area. Calculating the damage degree for each candidate building, finally, building damage map is generated. To evaluate the ability proposed method in generating damage map, a data set from Port-au-Prince, Haiti's capital after the 2010 Haiti earthquake was used. In this case, after calculating of all buildings in the test area using the proposed method, the results were compared to the damage degree which estimated through visual interpretation of post-event satellite image. Obtained results were proved the reliability of the proposed method in damage map generation using LiDAR data.
Comparison of different building shells - life cycle assessment.
Rixrath, Doris; Wartha, Christian
2016-07-01
The Renewable Energy and Efficiency Action (REACT) project is a European Union-funded cross-border cooperative venture featuring the participation of companies and researchers from the Austrian state of Burgenland and western Slovakia that is developing zero-energy concepts for newly built single-family homes. A variety of building structures are defined for family houses, and the different impacts they have on the environment are evaluated over the entire life cycle. This paper aims to compare the environmental impacts of different building shells during both the construction and the demolition phases. However, the operation phase of the building is not evaluated. One of the findings of the project thus far is that the demolition and disposal of building materials should be included in any such evaluation. For some environmental impact assessment categories, both demolition and disposal are important. The environmental impacts of various end-of-life scenarios can differ greatly based on the disposal method (e.g., landfill, incineration, recycling) chosen and on the proportion of recycled content. Furthermore, the results show that manufacturing building materials from renewable resources can have strong environmental impacts, particularly when substantial amounts of fossil fuel are required in their production. Integr Environ Assess Manag 2016;12:437-444. © 2016 SETAC. © 2016 SETAC.
Walter, Alexander I; Helgenberger, Sebastian; Wiek, Arnim; Scholz, Roland W
2007-11-01
Most Transdisciplinary Research (TdR) projects combine scientific research with the building of decision making capacity for the involved stakeholders. These projects usually deal with complex, societally relevant, real-world problems. This paper focuses on TdR projects, which integrate the knowledge of researchers and stakeholders in a collaborative transdisciplinary process through structured methods of mutual learning. Previous research on the evaluation of TdR has insufficiently explored the intended effects of transdisciplinary processes on the real world (societal effects). We developed an evaluation framework for assessing the societal effects of transdisciplinary processes. Outputs (measured as procedural and product-related involvement of the stakeholders), impacts (intermediate effects connecting outputs and outcomes) and outcomes (enhanced decision making capacity) are distinguished as three types of societal effects. Our model links outputs and outcomes of transdisciplinary processes via the impacts using a mediating variables approach. We applied this model in an ex post evaluation of a transdisciplinary process. 84 out of 188 agents participated in a survey. The results show significant mediation effects of the two impacts "network building" and "transformation knowledge". These results indicate an influence of a transdisciplinary process on the decision making capacity of stakeholders, especially through social network building and the generation of knowledge relevant for action.
BOCA BASIC BUILDING CODE. 4TH ED., 1965 AND 1967. BOCA BASIC BUILDING CODE ACCUMULATIVE SUPPLEMENT.
ERIC Educational Resources Information Center
Building Officials Conference of America, Inc., Chicago, IL.
NATIONALLY RECOGNIZED STANDARDS FOR THE EVALUATION OF MINIMUM SAFE PRACTICE OR FOR DETERMINING THE PERFORMANCE OF MATERIALS OR SYSTEMS OF CONSTRUCTION HAVE BEEN COMPILED AS AN AID TO DESIGNERS AND LOCAL OFFICIALS. THE CODE PRESENTS REGULATIONS IN TERMS OF MEASURED PERFORMANCE RATHER THAN IN RIGID SPECIFICATION OF MATERIALS OR METHODS. THE AREAS…
Building research and evaluation capacity in population health: the NSW Health approach.
Edwards, Barry; Stickney, Beth; Milat, Andrew; Campbell, Danielle; Thackway, Sarah
2016-02-01
Issue addressed An organisational culture that values and uses research and evaluation (R&E) evidence to inform policy and practice is fundamental to improving health outcomes. The 2016 NSW Government Program Evaluation Guidelines recommend investment in training and development to improve evaluation capacity. The purpose of this paper is to outline the approaches taken by the NSW Ministry of Health to develop R&E capacity and assess these against existing models of practice. Method The Ministry of Health's Centre for Epidemiology and Evidence (CEE) takes an evidence-based approach to building R&E capacity in population health. Strategies are informed by: the NSW Population Health Research Strategy, R&E communities of practice across the Ministry and health Pillar agencies and a review of the published evidence on evaluation capacity building (ECB). An internal survey is conducted biennially to monitor research activity within the Ministry's Population and Public Health Division. One representative from each of the six centres that make up the Division coordinates completion of the survey by relevant staff members for their centre. Results The review identified several ECB success factors including: implementing a tailored multifaceted approach; an organisational commitment to R&E; and offering experiential training and ongoing technical support to the workforce. The survey of research activity found that the Division funded a mix of research assets, research funding schemes, research centres and commissioned R&E projects. CEE provides technical advice and support services for staff involved in R&E and in 2015, 22 program evaluations were supported. R&E capacity building also includes a series of guides to assist policy makers, practitioners and researchers to commission, undertake and use policy-relevant R&E. Staff training includes workshops on critical appraisal, program logic and evaluation methods. From January 2013 to June 2014 divisional staff published 84 peer-reviewed papers and one book chapter. Conclusion A strategic approach to R&E capacity building compares favourably with organisational dimensions of ECB and has facilitated the generation of high quality population health R&E in NSW. So what? An evidence-based multistrategy approach to population health R&E can result in substantial contributions to the population-health evidence base.
NASA Astrophysics Data System (ADS)
Abdel Raheem, Shehata E.; Ahmed, Mohamed M.; Alazrak, Tarek M. A.
2015-03-01
Soil conditions have a great deal to do with damage to structures during earthquakes. Hence the investigation on the energy transfer mechanism from soils to buildings during earthquakes is critical for the seismic design of multi-story buildings and for upgrading existing structures. Thus, the need for research into soil-structure interaction (SSI) problems is greater than ever. Moreover, recent studies show that the effects of SSI may be detrimental to the seismic response of structure and neglecting SSI in analysis may lead to un-conservative design. Despite this, the conventional design procedure usually involves assumption of fixity at the base of foundation neglecting the flexibility of the foundation, the compressibility of the underneath soil and, consequently, the effect of foundation settlement on further redistribution of bending moment and shear force demands. Hence the SSI analysis of multi-story buildings is the main focus of this research; the effects of SSI are analyzed for typical multi-story building resting on raft foundation. Three methods of analysis are used for seismic demands evaluation of the target moment-resistant frame buildings: equivalent static load; response spectrum methods and nonlinear time history analysis with suit of nine time history records. Three-dimensional FE model is constructed to investigate the effects of different soil conditions and number of stories on the vibration characteristics and seismic response demands of building structures. Numerical results obtained using SSI model with different soil conditions are compared to those corresponding to fixed-base support modeling assumption. The peak responses of story shear, story moment, story displacement, story drift, moments at beam ends, as well as force of inner columns are analyzed. The results of different analysis approaches are used to evaluate the advantages, limitations, and ease of application of each approach for seismic analysis.
Assessment method of accessibility conditions: how to make public buildings accessible?
Andrade, Isabela Fernandes; Ely, e Vera Helena Moro Bins
2012-01-01
The enforcement of accessibility today has faced several difficulties, such as intervention in historic buildings that now house public services and cultural activities, such as town halls, museums and theaters and should allow access, on equal terms to all people. The paper presents the application of a method for evaluating the spatial accessibility conditions and their results. For this, we sought to support the theoretical foundation about the main issue involved and legislation. From the method used--guided walks--it was possible to identify the main barriers to accessibility in historic buildings. From the identified barriers, possible solutions are presented according to the four components of accessibility: spatial orientation, displacement, use and communication. It is hoped also that the knowledge gained in this research contributes to an improvement of accessibility legislation in relation to the listed items.
Efficient visualization of urban spaces
NASA Astrophysics Data System (ADS)
Stamps, A. E.
2012-10-01
This chapter presents a new method for calculating efficiency and applies that method to the issues of selecting simulation media and evaluating the contextual fit of new buildings in urban spaces. The new method is called "meta-analysis". A meta-analytic review of 967 environments indicated that static color simulations are the most efficient media for visualizing urban spaces. For contextual fit, four original experiments are reported on how strongly five factors influence visual appeal of a street: architectural style, trees, height of a new building relative to the heights of existing buildings, setting back a third story, and distance. A meta-analysis of these four experiments and previous findings, covering 461 environments, indicated that architectural style, trees, and height had effects strong enough to warrant implementation, but the effects of setting back third stories and distance were too small to warrant implementation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mims, Natalie; Schiller, Steven R.; Stuart, Elizabeth
In the last decade, a new policy area has emerged to boost energy efficiency in buildings that focuses on the simple action of measuring energy use as compared to buildings of similar type and size, and making that data publicly available. These efforts, referred to as benchmarking and transparency (B&T) policies, seek to unlock new energy efficiency opportunities in the country’s existing buildings by promoting data-driven decision-making and creating stronger market signals. This report focuses on the 24 state and local jurisdictions that (as of December 31, 2016) require owners of privately owned commercial buildings, multifamily buildings, or both tomore » comply with a B&T policy. The report provides a summary of U.S. B&T policy design and implementation characteristics, reports results and impacts for jurisdictions with B&T policies, and discusses opportunities for increasing the efficacy of B&T policies, as well as suggested areas for further research. Among the findings, all but one of the B&T policy evaluation studies reviewed indicate some reduction (from 1.6% to 14%) in energy use, energy costs, or energy intensity over the two- to four-year period of the analyses. More specifically, most of the studies reviewed indicate 3% to 8% reductions in gross energy consumption or energy use intensity over a two- to four-year period of B&T policy implementation. Two additional evaluation studies indicate that there is a causal relationship between B&T policies and energy savings or energy cost savings. These documented impacts should be reviewed with some caution. While consistently showing energy savings benefits associated with B&T policies, these savings estimates should be considered preliminary because of the limited period of analyses and inconsistencies in analysis methods for the various studies. A nationally standardized method for data collection, reporting, and evaluation of B&T policies—developed with an advisory group of state and local jurisdictions, energy efficiency and evaluation experts, building owner and real estate associations, and other stakeholders—could improve the consistency and quality of B&T impact studies, providing policymakers and others with a more complete understanding of the present and future impacts of these policies.« less
Improving the explanation capabilities of advisory systems
NASA Technical Reports Server (NTRS)
Porter, Bruce; Souther, Art
1993-01-01
A major limitation of current advisory systems (e.g., intelligent tutoring systems and expert systems) is their restricted ability to give explanations. The goal of our research is to develop and evaluate a flexible explanation facility, one that can dynamically generate responses to questions not anticipated by the system's designers and that can tailor these responses to individual users. To achieve this flexibility, we are developing a large knowledge base, a viewpoint construction facility, and a modeling facility. In the long term we plan to build and evaluate advisory systems with flexible explanation facilities for scientists in numerous domains. In the short term, we are focusing on a single complex domain in biological science, and we are working toward two important milestones: (1) building and evaluating an advisory system with a flexible explanation facility for freshman-level students studying biology; and (2) developing general methods and tools for building similar explanation facilities in other domains.
Improving the explanation capabilities of advisory systems
NASA Technical Reports Server (NTRS)
Porter, Bruce; Souther, Art
1994-01-01
A major limitation of current advisory systems (e.g., intelligent tutoring systems and expert systems) is their restricted ability to give explanations. The goal of our research is to develop and evaluate a flexible explanation facility, one that can dynamically generate responses to questions not anticipated by the system's designers and that can tailor these responses to individual users. To achieve this flexibility, we are developing a large knowledge base, a viewpoint construction facility, and a modeling facility. In the long term we plan to build and evaluate advisory systems with flexible explanation facilities for scientists in numerous domains. In the short term, we are focusing on a single complex domain in biological science, and we are working toward two important milestones: (1) building and evaluating an advisory system with a flexible explanation facility for freshman-level students studying biology, and (2) developing general methods and tools for building similar explanation facilities in other domains.
Review on Rapid Seismic Vulnerability Assessment for Bulk of Buildings
NASA Astrophysics Data System (ADS)
Nanda, R. P.; Majhi, D. R.
2013-09-01
This paper provides a brief overview of rapid visual screening (RVS) procedures available in different countries with a comparison among all the methods. Seismic evaluation guidelines from, USA, Canada, Japan, New Zealand, India, Europe, Italy, UNDP, with other methods are reviewed from the perspective of their applicability to developing countries. The review shows clearly that some of the RVS procedures are unsuited for potential use in developing countries. It is expected that this comparative assessment of various evaluation schemes will help to identify the most essential components of such a procedure for use in India and other developing countries, which is not only robust, reliable but also easy to use with available resources. It appears that Federal Emergency Management Agency (FEMA) 154 and New Zealand Draft Code approaches can be suitably combined to develop a transparent, reasonably rigorous and generalized procedure for seismic evaluation of buildings in developing countries.
Evaluation on Cost Overrun Risks of Long-distance Water Diversion Project Based on SPA-IAHP Method
NASA Astrophysics Data System (ADS)
Yuanyue, Yang; Huimin, Li
2018-02-01
Large investment, long route, many change orders and etc. are main causes for costs overrun of long-distance water diversion project. This paper, based on existing research, builds a full-process cost overrun risk evaluation index system for water diversion project, apply SPA-IAHP method to set up cost overrun risk evaluation mode, calculate and rank weight of every risk evaluation indexes. Finally, the cost overrun risks are comprehensively evaluated by calculating linkage measure, and comprehensive risk level is acquired. SPA-IAHP method can accurately evaluate risks, and the reliability is high. By case calculation and verification, it can provide valid cost overrun decision making information to construction companies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Yan; Treado, Stephen J.; Messner, John I.
Building control systems for Heating, Ventilation, and Air Conditioning (HVAC) play a key role in realizing the functionality and operation of building systems and components. Building Control Knowledge (BCK) is the logic and algorithms embedded throughout building control system. There are different methods to represent the BCK. These methods differ in the selection of BCK representing elements and the format of those elements. There is a lack of standard data schema, for storing, retrieving, and reusing structured BCK. In this study, a modular data schema is created for BCK representation. The data schema contains eleven representing elements, i.e., control modulemore » name, operation mode, system schematic, control flow diagram, data point, alarm, parameter, control sequence, function, and programming code. Each element is defined with specific attributes. This data schema is evaluated through a case study demonstration. The demonstration shows a new way to represent the BCK with standard formats.« less
Estimation of the behavior factor of existing RC-MRF buildings
NASA Astrophysics Data System (ADS)
Vona, Marco; Mastroberti, Monica
2018-01-01
In recent years, several research groups have studied a new generation of analysis methods for seismic response assessment of existing buildings. Nevertheless, many important developments are still needed in order to define more reliable and effective assessment procedures. Moreover, regarding existing buildings, it should be highlighted that due to the low knowledge level, the linear elastic analysis is the only analysis method allowed. The same codes (such as NTC2008, EC8) consider the linear dynamic analysis with behavior factor as the reference method for the evaluation of seismic demand. This type of analysis is based on a linear-elastic structural model subject to a design spectrum, obtained by reducing the elastic spectrum through a behavior factor. The behavior factor (reduction factor or q factor in some codes) is used to reduce the elastic spectrum ordinate or the forces obtained from a linear analysis in order to take into account the non-linear structural capacities. The behavior factors should be defined based on several parameters that influence the seismic nonlinear capacity, such as mechanical materials characteristics, structural system, irregularity and design procedures. In practical applications, there is still an evident lack of detailed rules and accurate behavior factor values adequate for existing buildings. In this work, some investigations of the seismic capacity of the main existing RC-MRF building types have been carried out. In order to make a correct evaluation of the seismic force demand, actual behavior factor values coherent with force based seismic safety assessment procedure have been proposed and compared with the values reported in the Italian seismic code, NTC08.
Spatial Information in Support of 3D Flood Damage Assessment of Buildings at Micro Level: A Review
NASA Astrophysics Data System (ADS)
Amirebrahimi, S.; Rajabifard, A.; Sabri, S.; Mendis, P.
2016-10-01
Floods, as the most common and costliest natural disaster around the globe, have adverse impacts on buildings which are considered as major contributors to the overall economic damage. With emphasis on risk management methods for reducing the risks to structures and people, estimating damage from potential flood events becomes an important task for identifying and implementing the optimal flood risk-reduction solutions. While traditional Flood Damage Assessment (FDA) methods focus on simple representation of buildings for large-scale damage assessment purposes, recent emphasis on buildings' flood resilience resulted in development of a sophisticated method that allows for a detailed and effective damage evaluation at the scale of building and its components. In pursuit of finding the suitable spatial information model to satisfy the needs of implementing such frameworks, this article explores the technical developments for an effective representation of buildings, floods and other required information within the built environment. The search begins with the Geospatial domain and investigates the state-of-the-art and relevant developments from data point of view in this area. It is further extended to other relevant disciplines in the Architecture, Engineering and Construction domain (AEC/FM) and finally, even some overlapping areas between these domains are considered and explored.
Evaluating the interior thermal performance of mosques in the tropical environment
NASA Astrophysics Data System (ADS)
Nordin, N. I.; Misni, A.
2018-02-01
This study introduces the methodology applied in conducting data collection and data analysis. Data collection is the process of gathering and measuring information on targeted variables in an established systematic method. Qualitative and quantitative methods are combined in collecting data from government departments, site experiments and observation. Furthermore, analysing the indoor thermal performance data in the heritage and new mosques were used thermal monitoring tests, while validation will be made by meteorology data. Origin 8 version of the software is used to analyse all the data. Comparison techniques were applied to analyse several factors that influence the indoor thermal performance of mosques, namely building envelope include floor area, opening, and material used. Building orientation, location, surrounding vegetation and water elements are also recorded as supported building primary data. The comparison of primary data using these variables for four mosques include heritage and new buildings were revealed.
Thoracic Injury Risk Curves for Rib Deflections of the SID-IIs Build Level D.
Irwin, Annette L; Crawford, Greg; Gorman, David; Wang, Sikui; Mertz, Harold J
2016-11-01
Injury risk curves for SID-IIs thorax and abdomen rib deflections proposed for future NCAP side impact evaluations were developed from tests conducted with the SID-IIs FRG. Since the floating rib guide is known to reduce the magnitude of the peak rib deflections, injury risk curves developed from SID-IIs FRG data are not appropriate for use with SID-IIs build level D. PMHS injury data from three series of sled tests and one series of whole-body drop tests are paired with thoracic rib deflections from equivalent tests with SID-IIs build level D. Where possible, the rib deflections of SID-IIs build level D were scaled to adjust for differences in impact velocity between the PMHS and SID-IIs tests. Injury risk curves developed by the Mertz-Weber modified median rank method are presented and compared to risk curves developed by other parametric and non-parametric methods.
Selection of suitable NDT methods for building inspection
NASA Astrophysics Data System (ADS)
Pauzi Ismail, Mohamad
2017-11-01
Construction of modern structures requires good quality concrete with adequate strength and durability. Several accidents occurred in the civil constructions and were reported in the media. Such accidents were due to poor workmanship and lack of systematic monitoring during the constructions. In addition, water leaking and cracking in residential houses was commonly reported too. Based on these facts, monitoring the quality of concrete in structures is becoming more and more important subject. This paper describes major Non-destructive Testing (NDT) methods for evaluating structural integrity of concrete building. Some interesting findings during actual NDT inspections on site are presented. The NDT methods used are explained, compared and discussed. The suitable methods are suggested as minimum NDT methods to cover parameters required in the inspection.
Analysis of building deformation in landslide area using multisensor PSInSAR™ technique.
Ciampalini, Andrea; Bardi, Federica; Bianchini, Silvia; Frodella, William; Del Ventisette, Chiara; Moretti, Sandro; Casagli, Nicola
2014-12-01
Buildings are sensitive to movements caused by ground deformation. The mapping both of spatial and temporal distribution, and of the degree of building damages represents a useful tool in order to understand the landslide evolution, magnitude and stress distribution. The high spatial resolution of space-borne SAR interferometry can be used to monitor displacements related to building deformations. In particular, PSInSAR technique is used to map and monitor ground deformation with millimeter accuracy. The usefulness of the above mentioned methods was evaluated in San Fratello municipality (Sicily, Italy), which was historically affected by landslides: the most recent one occurred on 14th February 2010. PSInSAR data collected by ERS 1/2, ENVISAT, RADARSAT-1 were used to study the building deformation velocities before the 2010 landslide. The X-band sensors COSMO-SkyMed and TerraSAR-X were used in order to monitor the building deformation after this event. During 2013, after accurate field inspection on buildings and structures, damage assessment map of San Fratello were created and then compared to the building deformation velocity maps. The most interesting results were obtained by the comparison between the building deformation velocity map obtained through COSMO-SkyMed and the damage assessment map. This approach can be profitably used by local and Civil Protection Authorities to manage the post-event phase and evaluate the residual risks.
Knowledge-based model building of proteins: concepts and examples.
Bajorath, J.; Stenkamp, R.; Aruffo, A.
1993-01-01
We describe how to build protein models from structural templates. Methods to identify structural similarities between proteins in cases of significant, moderate to low, or virtually absent sequence similarity are discussed. The detection and evaluation of structural relationships is emphasized as a central aspect of protein modeling, distinct from the more technical aspects of model building. Computational techniques to generate and complement comparative protein models are also reviewed. Two examples, P-selectin and gp39, are presented to illustrate the derivation of protein model structures and their use in experimental studies. PMID:7505680
Theoretical basis of the DOE-2 building energy use analysis program
NASA Astrophysics Data System (ADS)
Curtis, R. B.
1981-04-01
A user-oriented, public domain, computer program was developed that will enable architects and engineers to perform design and retrofit studies of the energy-use of buildings under realistic weather conditions. The DOE-2.1A has been named by the US DOE as the standard evaluation technique for the Congressionally mandated building energy performance standards (BEPS). A number of program design decisions were made that determine the breadth of applicability of DOE-2.1. Such design decisions are intrinsic to all building energy use analysis computer programs and determine the types of buildings or the kind of HVAC systems that can be modeled. In particular, the weighting factor method used in DOE-2 has both advantages and disadvantages relative to other computer programs.
Ten-year monitoring of high-rise building columns using long-gauge fiber optic sensors
NASA Astrophysics Data System (ADS)
Glisic, B.; Inaudi, D.; Lau, J. M.; Fong, C. C.
2013-05-01
A large-scale lifetime building monitoring program was implemented in Singapore in 2001. The monitoring aims of this unique program were to increase safety, verify performance, control quality, increase knowledge, optimize maintenance costs, and evaluate the condition of the structures after a hazardous event. The first instrumented building, which has now been monitored for more than ten years, is presented in this paper. The long-gauge fiber optic strain sensors were embedded in fresh concrete of ground-level columns, thus the monitoring started at the birth of both the construction material and the structure. Measurement sessions were performed during construction, upon completion of each new story and the roof, and after the construction, i.e., in-service. Based on results it was possible to follow and evaluate long-term behavior of the building through every stage of its life. The results of monitoring were analyzed at a local (column) and global (building) level. Over-dimensioning of one column was identified. Differential settlement of foundations was detected, localized, and its magnitude estimated. Post-tremor analysis was performed. Real long-term behavior of concrete columns was assessed. Finally, the long-term performance of the monitoring system was evaluated. The researched monitoring method, monitoring system, rich results gathered over approximately ten years, data analysis algorithms, and the conclusions on the structural behavior and health condition of the building based on monitoring are presented in this paper.
Design and Evaluation of the NFL PLAY 60 FITNESSGRAM® Partnership Project
ERIC Educational Resources Information Center
Welk, Gregory J.; Bai, Yang; Saint-Maurice, Pedro F.; Allums-Featherston, Kelly; Candelaria, Norma
2016-01-01
This article describes the conceptual design and evaluation strategies used in the NFL PLAY 60 FITNESSGRAM® Partnership Project, a large participatory research network focused on building effective school physical education programming. The article summarizes the unique participatory design, recruitment methods, programming strategies, and…
Decisive management in selecting locations for development of construction projects
NASA Astrophysics Data System (ADS)
Szafranko, E.; Pawłowicz, J. A.
2017-08-01
The location of an investment project is one of the most important decisions in the construction and land development business. The shape of a new building and aspects of its future use depend on making a good choice of a land plot where it will be constructed. There are many characteristics involved descriptions of land available for development. On the one hand, different buildings (with different envisaged use) fit differently to a given location. Residential homes, for example, require a location which will ensure a peaceful lifestyle, with places for walks and recreation, situated in a relatively quite setting. On the other hand, close proximity to schools, shops or a health clinic is another important consideration. Industrial buildings should be localized so as not to be a nuisance to others, and their location should facilitate efficient transport of raw materials and ready products. Yet other requirements are defined for public buildings. It is therefore evident that the characteristics included in an evaluation of the location of a planned building can be highly diverse and their diversity makes the evaluation difficult. Selection of a location can be supported by a variety of methods. For instance, an evaluation can rely on assigning points which indicate the fulfillment of certain criteria. This approach generates a complex evaluation in the form of tables and maps of usefulness. Another possibility is to make an assessment of the criteria that a given land parcels should satisfy in order to develop a specific type of a building. Having combined these two sets of information, we can create a system or a model for the management of land resources, which will easily help to support decision making processes pertaining to the choice of a location. This article shows a model approach for a specific building.
Light scattering methods to test inorganic PCMs for application in buildings
NASA Astrophysics Data System (ADS)
De Paola, M. G.; Calabrò, V.; De Simone, M.
2017-10-01
Thermal performance and stability over time are key parameters for the characterization and application of PCMs in the building sector. Generally, inorganic PCMs are dispersions of hydrated salts and additives in water that counteract phase segregation phenomena and subcooling. Traditional methods or in “house” methods can be used for evaluating thermal properties, while stability can be estimated over time by using optical techniques. By considering this double approach, in this work thermal and structural analyses of Glauber salt based composite PCMs are conducted by means of non-conventional equipment: T-history method (thermal analysis) and Turbiscan (stability analysis). Three samples with the same composition (Glauber salt with additives) were prepared by using different sonication times and their thermal performances were compared by testing both the thermal cycling and the thermal properties. The stability of the mixtures was verified by the identification of destabilization phenomena, the evaluation of the migration velocities of particles and the estimation of variation of particle size.
NASA Astrophysics Data System (ADS)
Demmers, T. G. M.; Burgess, L. R.; Short, J. L.; Phillips, V. R.; Clark, J. A.; Wathes, C. M.
A method has been developed to measure the emission rate of ammonia from naturally ventilated U.K. livestock buildings. The method is based on measurements of ammonia concentration and estimates of the ventilation rate of the building by continuous release of carbon monoxide tracer within the building. The tracer concentration is measured at nine positions in openings around the perimeter of the building, as well as around a ring sampling line. Two criteria were evaluated to decide whether, at any given time, a given opening in the building acted as an air inlet or as an air outlet. Carbon monoxide concentration difference across an opening was found to be a better criterion than the temperature difference across the opening. Ammonia concentrations were measured continuously at the sampling points using a chemiluminescence analyser. The method was applied to a straw-bedded beef unit and to a slurry-based dairy unit. Both buildings were of space-boarded construction. Ventilation rates estimated by the ring line sample were consistently higher than by the perimeter samples. During calm weather, the ventilation estimates by both samples were similar (10-20 air changes h -1). However, during windy conditions (>5 m s -1) the ventilation rate was overestimated by the ring line sample (average 100 air changes h -1) compared to the perimeter samples (average 50 air changes h -1). The difference was caused by incomplete mixing of the tracer within the building. The ventilation rate estimated from the perimeter samples was used for the calculation of the emission rate. Preliminary estimates of the ammonia emission factor were 6.0 kg NH 3 (500 kg live-weight) -1 (190 d) -1 for the slurry-based dairy unit and 3.7 for the straw-bedded beef unit.
Bhattacharyya, Onil; Schull, Michael; Shojania, Kaveh; Stergiopoulos, Vicky; Naglie, Gary; Webster, Fiona; Brandao, Ricardo; Mohammed, Tamara; Christian, Jennifer; Hawker, Gillian; Wilson, Lynn; Levinson, Wendy
2016-01-01
Integrating care for people with complex needs is challenging. Indeed, evidence of solutions is mixed, and therefore, well-designed, shared evaluation approaches are needed to create cumulative learning. The Toronto-based Building Bridges to Integrate Care (BRIDGES) collaborative provided resources to refine and test nine new models linking primary, hospital and community care. It used mixed methods, a cross-project meta-evaluation and shared outcome measures. Given the range of skills required to develop effective interventions, a novel incubator was used to test and spread opportunities for system integration that included operational expertise and support for evaluation and process improvement.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Granderson, Jessica; Touzani, Samir; Custodio, Claudine
Trustworthy savings calculations are critical to convincing investors in energy efficiency projects of the benefit and cost-effectiveness of such investments and their ability to replace or defer supply-side capital investments. However, today’s methods for measurement and verification (M&V) of energy savings constitute a significant portion of the total costs of efficiency projects. They also require time-consuming manual data acquisition and often do not deliver results until years after the program period has ended. The rising availability of “smart” meters, combined with new analytical approaches to quantifying savings, has opened the door to conducting M&V more quickly and at lower cost,more » with comparable or improved accuracy. These meter- and software-based approaches, increasingly referred to as “M&V 2.0”, are the subject of surging industry interest, particularly in the context of utility energy efficiency programs. Program administrators, evaluators, and regulators are asking how M&V 2.0 compares with more traditional methods, how proprietary software can be transparently performance tested, how these techniques can be integrated into the next generation of whole-building focused efficiency programs. This paper expands recent analyses of public-domain whole-building M&V methods, focusing on more novel M&V2.0 modeling approaches that are used in commercial technologies, as well as approaches that are documented in the literature, and/or developed by the academic building research community. We present a testing procedure and metrics to assess the performance of whole-building M&V methods. We then illustrate the test procedure by evaluating the accuracy of ten baseline energy use models, against measured data from a large dataset of 537 buildings. The results of this study show that the already available advanced interval data baseline models hold great promise for scaling the adoption of building measured savings calculations using Advanced Metering Infrastructure (AMI) data. Median coefficient of variation of the root mean squared error (CV(RMSE)) was less than 25% for every model tested when twelve months of training data were used. With even six months of training data, median CV(RMSE) for daily energy total was under 25% for all models tested. Finally, these findings can be used to build confidence in model robustness, and the readiness of these approaches for industry uptake and adoption« less
Granderson, Jessica; Touzani, Samir; Custodio, Claudine; ...
2016-04-16
Trustworthy savings calculations are critical to convincing investors in energy efficiency projects of the benefit and cost-effectiveness of such investments and their ability to replace or defer supply-side capital investments. However, today’s methods for measurement and verification (M&V) of energy savings constitute a significant portion of the total costs of efficiency projects. They also require time-consuming manual data acquisition and often do not deliver results until years after the program period has ended. The rising availability of “smart” meters, combined with new analytical approaches to quantifying savings, has opened the door to conducting M&V more quickly and at lower cost,more » with comparable or improved accuracy. These meter- and software-based approaches, increasingly referred to as “M&V 2.0”, are the subject of surging industry interest, particularly in the context of utility energy efficiency programs. Program administrators, evaluators, and regulators are asking how M&V 2.0 compares with more traditional methods, how proprietary software can be transparently performance tested, how these techniques can be integrated into the next generation of whole-building focused efficiency programs. This paper expands recent analyses of public-domain whole-building M&V methods, focusing on more novel M&V2.0 modeling approaches that are used in commercial technologies, as well as approaches that are documented in the literature, and/or developed by the academic building research community. We present a testing procedure and metrics to assess the performance of whole-building M&V methods. We then illustrate the test procedure by evaluating the accuracy of ten baseline energy use models, against measured data from a large dataset of 537 buildings. The results of this study show that the already available advanced interval data baseline models hold great promise for scaling the adoption of building measured savings calculations using Advanced Metering Infrastructure (AMI) data. Median coefficient of variation of the root mean squared error (CV(RMSE)) was less than 25% for every model tested when twelve months of training data were used. With even six months of training data, median CV(RMSE) for daily energy total was under 25% for all models tested. Finally, these findings can be used to build confidence in model robustness, and the readiness of these approaches for industry uptake and adoption« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nesvijski, E.; Nesvijski, T.
1996-12-31
Concrete as one of the main construction materials, which is used for building of industrial and civil structures, highways, bridges, etc. requires periodical evaluation of its properties by different nondestructive methods. Application of acoustic emission (AE) for these purposes occupies a modest place among other nondestructive methods. But the AE methods proved to be very effective for testing of concrete and reinforced concrete elements and structures under load. This work is devoted to an important, from methodological point of view, problem connected with two opposite effects: of Kaiser and of Felicity, and their application for evaluation of concrete by themore » AE method.« less
Building a Relationship between Elements of Product Form Features and Vocabulary Assessment Models
ERIC Educational Resources Information Center
Lo, Chi-Hung
2016-01-01
Based on the characteristic feature parameterization and the superiority evaluation method (SEM) in extension engineering, a product-shape design method was proposed in this study. The first step of this method is to decompose the basic feature components of a product. After that, the morphological chart method is used to segregate the ideas so as…
Village Building Identification Based on Ensemble Convolutional Neural Networks
Guo, Zhiling; Chen, Qi; Xu, Yongwei; Shibasaki, Ryosuke; Shao, Xiaowei
2017-01-01
In this study, we present the Ensemble Convolutional Neural Network (ECNN), an elaborate CNN frame formulated based on ensembling state-of-the-art CNN models, to identify village buildings from open high-resolution remote sensing (HRRS) images. First, to optimize and mine the capability of CNN for village mapping and to ensure compatibility with our classification targets, a few state-of-the-art models were carefully optimized and enhanced based on a series of rigorous analyses and evaluations. Second, rather than directly implementing building identification by using these models, we exploited most of their advantages by ensembling their feature extractor parts into a stronger model called ECNN based on the multiscale feature learning method. Finally, the generated ECNN was applied to a pixel-level classification frame to implement object identification. The proposed method can serve as a viable tool for village building identification with high accuracy and efficiency. The experimental results obtained from the test area in Savannakhet province, Laos, prove that the proposed ECNN model significantly outperforms existing methods, improving overall accuracy from 96.64% to 99.26%, and kappa from 0.57 to 0.86. PMID:29084154
Global localization of 3D point clouds in building outline maps of urban outdoor environments.
Landsiedel, Christian; Wollherr, Dirk
2017-01-01
This paper presents a method to localize a robot in a global coordinate frame based on a sparse 2D map containing outlines of building and road network information and no location prior information. Its input is a single 3D laser scan of the surroundings of the robot. The approach extends the generic chamfer matching template matching technique from image processing by including visibility analysis in the cost function. Thus, the observed building planes are matched to the expected view of the corresponding map section instead of to the entire map, which makes a more accurate matching possible. Since this formulation operates on generic edge maps from visual sensors, the matching formulation can be expected to generalize to other input data, e.g., from monocular or stereo cameras. The method is evaluated on two large datasets collected in different real-world urban settings and compared to a baseline method from literature and to the standard chamfer matching approach, where it shows considerable performance benefits, as well as the feasibility of global localization based on sparse building outline data.
Field Impact Evaluation Process on Electronic Tabular Display Subsystem (ETABS).
1979-10-01
structural and process techniques are described. These include a diagonal slice approach to team formulation and several different methods of team building, process control and conflict management . (Author)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Judkoff, R.; Neymark, J.
2013-07-01
ANSI/ASHRAE Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs applies the IEA BESTEST building thermal fabric test cases and example simulation results originally published in 1995. These software accuracy test cases and their example simulation results, which comprise the first test suite adapted for the initial 2001 version of Standard 140, are approaching their 20th anniversary. In response to the evolution of the state of the art in building thermal fabric modeling since the test cases and example simulation results were developed, work is commencing to update the normative test specification and themore » informative example results.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Judkoff, R.; Neymark, J.
2013-07-01
ANSI/ASHRAE Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs applies the IEA BESTEST building thermal fabric test cases and example simulation results originally published in 1995. These software accuracy test cases and their example simulation results, which comprise the first test suite adapted for the initial 2001 version of Standard 140, are approaching their 20th anniversary. In response to the evolution of the state of the art in building thermal fabric modeling since the test cases and example simulation results were developed, work is commencing to update the normative test specification and themore » informative example results.« less
Ethnographic methods for process evaluations of complex health behaviour interventions.
Morgan-Trimmer, Sarah; Wood, Fiona
2016-05-04
This article outlines the contribution that ethnography could make to process evaluations for trials of complex health-behaviour interventions. Process evaluations are increasingly used to examine how health-behaviour interventions operate to produce outcomes and often employ qualitative methods to do this. Ethnography shares commonalities with the qualitative methods currently used in health-behaviour evaluations but has a distinctive approach over and above these methods. It is an overlooked methodology in trials of complex health-behaviour interventions that has much to contribute to the understanding of how interventions work. These benefits are discussed here with respect to three strengths of ethnographic methodology: (1) producing valid data, (2) understanding data within social contexts, and (3) building theory productively. The limitations of ethnography within the context of process evaluations are also discussed.
Evaluation of tsunami risk in Heraklion city, Crete, Greece, by using GIS methods
NASA Astrophysics Data System (ADS)
Triantafyllou, Ioanna; Fokaefs, Anna; Novikova, Tatyana; Papadopoulos, Gerasimos A.; Vaitis, Michalis
2016-04-01
The Hellenic Arc is the most active seismotectonic structure in the Mediterranean region. The island of Crete occupies the central segment of the arc which is characterized by high seismic and tsunami activity. Several tsunamis generated by large earthquakes, volcanic eruptions and landslides were reported that hit the capital city of Heraklion in the historical past. We focus our tsunami risk study in the northern coastal area of Crete (ca. 6 km in length and 1 km in maximum width) which includes the western part of the city of Heraklion and a large part of the neighboring municipality of Gazi. The evaluation of tsunami risk included calculations and mapping with QGIS of (1) cost for repairing buildings after tsunami damage, (2) population exposed to tsunami attack, (3) optimum routes and times for evacuation. To calculate the cost for building reparation after a tsunami attack we have determined the tsunami inundation zone in the study area after numerical simulations for extreme tsunami scenarios. The geographical distribution of buildings per building block, obtained from the 2011 census data of the Hellenic Statistical Authority (EL.STAT) and satellite data, was mapped. By applying the SCHEMA Damage Tool we assessed the building vulnerability to tsunamis according to the types of buildings and their expected damage from the hydrodynamic impact. A set of official cost rates varying with the building types and the damage levels, following standards set by the state after the strong damaging earthquakes in Greece in 2014, was applied to calculate the cost of rebuilding or repairing buildings damaged by the tsunami. In the investigation of the population exposed to tsunami inundation we have used the interpolation method to smooth out the population geographical distribution per building block within the inundation zone. Then, the population distribution was correlated with tsunami hydrodynamic parameters in the inundation zone. The last approach of tsunami risk assessment refers to the selection of optimal routes and times needed for evacuation from certain points within the inundation zone to a number of shelters outside the zone. The three different approaches were evaluated as for their overall contribution in the development of a plan for the tsunami risk mitigation. This research is a contribution to the EU-FP7 tsunami research project ASTARTE (Assessment, Strategy And Risk Reduction for Tsunamis in Europe), grant agreement no: 603839, 2013-10-30.
Influence of Type of Frequency Weighting Function On VDV Analysis
NASA Astrophysics Data System (ADS)
Kowalska-Koczwara, Alicja; Stypuła, Krzysztof
2017-10-01
Transport vibrations are the subject of many research, mostly their influence on structural elements of the building is investigated. However, nowadays, especially in the centres of large cities were apartments, residential buildings are closer to the transport vibration sources, an increasing attention is given to providing vibrational comfort to humans in buildings. Currently, in most countries, two main methods of evaluation are used: root mean squared method (RMS) and vibration dose value (VDV). In this article, VDV method is presented and the analysis of the weighting functions selection on value of VDV is made. Measurements required for the analysis were made in Krakow, on masonry, residential, two storey building located in the city centre. The building is subjected into two transport vibration sources: tram passages and vehicle passages on very close located road. Measurement points were located on the basement wall at ground level to control the excitation and in the middle of the floor on the highest storey (in the place where people percept vibration). The room chosen for measurements is located closest to the transport excitation sources. During the measurements, 25 vibration events were recorded and analysed. VDV values were calculated for three different weighting functions according to standard: ISO 2631-1, ISO 2631-2 and BS-6841. Differences in VDV values are shown, but also influence of the weighting function selection on result of evaluation is also presented. VDV analysis was performed not only for the individual vibration event but also all day and night vibration exposure were calculated using formulas contained in the annex to the standard BS-6841. It is demonstrated that, although there are differences in the values of VDV, an influence on all day and night exposure is no longer so significant.
NASA Astrophysics Data System (ADS)
Cao, Qiong; Gu, Lingjia; Ren, Ruizhi; Wang, Lang
2016-09-01
Building extraction currently is important in the application of high-resolution remote sensing imagery. At present, quite a few algorithms are available for detecting building information, however, most of them still have some obvious disadvantages, such as the ignorance of spectral information, the contradiction between extraction rate and extraction accuracy. The purpose of this research is to develop an effective method to detect building information for Chinese GF-1 data. Firstly, the image preprocessing technique is used to normalize the image and image enhancement is used to highlight the useful information in the image. Secondly, multi-spectral information is analyzed. Subsequently, an improved morphological building index (IMBI) based on remote sensing imagery is proposed to get the candidate building objects. Furthermore, in order to refine building objects and further remove false objects, the post-processing (e.g., the shape features, the vegetation index and the water index) is employed. To validate the effectiveness of the proposed algorithm, the omission errors (OE), commission errors (CE), the overall accuracy (OA) and Kappa are used at final. The proposed method can not only effectively use spectral information and other basic features, but also avoid extracting excessive interference details from high-resolution remote sensing images. Compared to the original MBI algorithm, the proposed method reduces the OE by 33.14% .At the same time, the Kappa increase by 16.09%. In experiments, IMBI achieved satisfactory results and outperformed other algorithms in terms of both accuracies and visual inspection
Comprehensive evaluation on low-carbon development of coal enterprise groups.
Wang, Bang-Jun; Wu, Yan-Fang; Zhao, Jia-Lu
2017-12-19
Scientifically evaluating the level of low-carbon development in terms of theoretical and practical significance is extremely important to coal enterprise groups for implementing national energy-related systems. This assessment can assist in building institutional mechanisms that are conducive for the economic development of coal business cycle and energy conservation as well as promoting the healthy development of coal enterprises to realize coal scientific development and resource utilization. First, by adopting systematic analysis method, this study builds low-carbon development evaluation index system for coal enterprise groups. Second, to determine the weight serving as guideline and criteria of the index, analytic hierarchy process (AHP) is applied using integrated linear weighted sum method to evaluate the level of low-carbon development of coal enterprise groups. Evaluation is also performed by coal enterprise groups, and the process comprises field analysis and evaluation. Finally, industrial policies are proposed regarding the development of low-carbon coal conglomerate strategies and measures. This study aims mainly to guide the low-carbon development of coal enterprise groups, solve the problem of coal mining and the destruction of ecological environment, support the conservation of raw materials and various resources, and achieve the sustainable development of the coal industry.
Tumiel-Berhalter, Laurene M; McLaughlin-Diaz, Victoria; Vena, John; Crespo, Carlos J
2007-01-01
Education and training build community research capacity and have impact on improvements of health outcomes. This manuscript describes the training and educational approaches to building research capacity that were utilized in a community-based participatory research program serving a Puerto Rican population and identifies barriers and strategies for overcoming them. A process evaluation identified a multitiered approach to training and education that was critical to reaching the broad community. This approach included four major categories providing a continuum of education and training opportunities: networking, methods training, on-the-job experience, and community education. Participation in these opportunities supported the development of a registry, the implementation of a survey, and two published manuscripts. Barriers included the lack of a formal evaluation of the education and training components, language challenges that limited involvement of ethnic groups other than Puerto Ricans, and potential biases associated with the familiarity of the data collector and the participant. The CBPR process facilitated relationship development between the university and the community and incorporated the richness of the community experience into research design. Strategies for improvement include incorporating evaluation into every training and educational opportunity and developing measures to quantify research capacity at the individual and community levels. Evaluating training and education in the community allows researchers to quantify the impact of CBPR on building community research capacity.
Gotovac, Sandra; Espinet, Stacey; Naqvi, Reza; Lingard, Lorelei; Steele, Margaret
2018-04-01
The need for child/adolescent mental health care in Canada is growing. Primary care can play a key role in filling this gap, yet most providers feel they do not have adequate training. This paper reviews the Canadian literature on capacity building programs in child and adolescent psychiatry for primary care providers, to examine how these programs are being implemented and evaluated to contribute to evidence-based initiatives. A systematic literature review of peer-reviewed published articles of capacity building initiatives in child/adolescent mental health care for primary care practitioners that have been implemented in Canada. Sixteen articles were identified that met inclusion criteria. Analysis revealed that capacity building initiatives in Canada are varied but rigorous evaluation methodology is lacking. Primary care providers welcome efforts to increase mental health care capacity and were satisfied with the implementation of most programs. Objective conclusions regarding the effectiveness of these programs to increase mental health care capacity is challenging given the evaluation methodology of these studies. Rigorous evaluation methods are needed to make evidence-based decisions on ways forward to be able to build child/adolescent mental health care capacity in primary care. Outcome measures need to move beyond self-report to more objective measures, and should expand the measurement of patient outcomes to ensure that these initiative are indeed leading to improved care for families.
Demand Response Resource Quantification with Detailed Building Energy Models
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hale, Elaine; Horsey, Henry; Merket, Noel
Demand response is a broad suite of technologies that enables changes in electrical load operations in support of power system reliability and efficiency. Although demand response is not a new concept, there is new appetite for comprehensively evaluating its technical potential in the context of renewable energy integration. The complexity of demand response makes this task difficult -- we present new methods for capturing the heterogeneity of potential responses from buildings, their time-varying nature, and metrics such as thermal comfort that help quantify likely acceptability of specific demand response actions. Computed with an automated software framework, the methods are scalable.
Computational modeling of latent-heat-storage in PCM modified interior plaster
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fořt, Jan; Maděra, Jiří; Trník, Anton
2016-06-08
The latent heat storage systems represent a promising way for decrease of buildings energy consumption with respect to the sustainable development principles of building industry. The presented paper is focused on the evaluation of the effect of PCM incorporation on thermal performance of cement-lime plasters. For basic characterization of the developed materials, matrix density, bulk density, and total open porosity are measured. Thermal conductivity is accessed by transient impulse method. DSC analysis is used for the identification of phase change temperature during the heating and cooling process. Using DSC data, the temperature dependent specific heat capacity is calculated. On themore » basis of the experiments performed, the supposed improvement of the energy efficiency of characteristic building envelope system where the designed plasters are likely to be used is evaluated by a computational analysis. Obtained experimental and computational results show a potential of PCM modified plasters for improvement of thermal stability of buildings and moderation of interior climate.« less
Evaluation of Advanced Polymers for Additive Manufacturing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rios, Orlando; Carter, William G.; Kutchko, Cindy
The goal of this Manufacturing Demonstration Facility (MDF) technical collaboration project between Oak Ridge National Laboratory (ORNL) and PPG Industries, Inc. (PPG) was to evaluate the feasibility of using conventional coatings chemistry and technology to build up material layer-by-layer. The PPG-ORNL study successfully demonstrated that polymeric coatings formulations may overcome many limitations of common thermoplastics used in additive manufacturing (AM), allow lightweight nozzle design for material deposition, and increase build rate. The materials effort focused on layer-by-layer deposition of coatings with each layer fusing together. The combination of materials and deposition results in an additively manufactured build that has sufficientmore » mechanical properties to bear the load of additional layers, yet is capable of bonding across the z-layers to improve build direction strength. The formulation properties were tuned to enable a novel, high-throughput deposition method that is highly scalable, compatible with high loading of reinforcing fillers, and inherently low-cost.« less
NASA Astrophysics Data System (ADS)
Lewis, Geoffrey Mcdowell
Sustainability is a word that represents a wide spectrum of complex and interrelated topics, but it is fundamentally a concept that describes a balanced relationship with the physical environment. There is a need for timely feedback on that relationship in order for individuals and societies to make informed decisions. Investigating the relationship between the physical form of our cities and regions and the impacts that these regions have on their supporting ecological environment requires both a method for categorizing form and a method for quantifying impact. The latter was addressed through the development of the regional characteristic curve method. This method collects, summarizes, analyzes, and displays spatial data in a graphical form that is intuitive, informative, and has advantages over existing tabular methods. Regional characteristic curves are calculated using concentric rings as the basis for evaluating impact metrics from any kind of areal data. The method was investigated in an examination of spatial change over time in the Ann Arbor region and in a comparison between Ann Arbor and Detroit. Curves for several types of metrics were used, based on land-cover and demographic data. The lack of a suitable energy use data set was highlighted, as well as great impact that energy use causes. One aspect of energy use, energy use in buildings, was singled out for further investigation. The possible link between building energy use and thermal image data collected by satellite was explored. Satellite thermal image data has been shown to be primarily related to variation in land-cover, but remaining variability in satellite data may be related to energy use in buildings. This link was investigated in both summer and winter case studies, revealing no significant relationship in summer and a weak relationship in winter. The winter relationship was also in a counterintuitive direction, in that higher building energy use was associated with cooler thermal image data. The poor spatial resolution and timing of the satellite data collection were not advantageous, so the presence of even a weak and counterintuitive result encouraged further exploration of this topic.
Physical and JIT Model Based Hybrid Modeling Approach for Building Thermal Load Prediction
NASA Astrophysics Data System (ADS)
Iino, Yutaka; Murai, Masahiko; Murayama, Dai; Motoyama, Ichiro
Energy conservation in building fields is one of the key issues in environmental point of view as well as that of industrial, transportation and residential fields. The half of the total energy consumption in a building is occupied by HVAC (Heating, Ventilating and Air Conditioning) systems. In order to realize energy conservation of HVAC system, a thermal load prediction model for building is required. This paper propose a hybrid modeling approach with physical and Just-in-Time (JIT) model for building thermal load prediction. The proposed method has features and benefits such as, (1) it is applicable to the case in which past operation data for load prediction model learning is poor, (2) it has a self checking function, which always supervises if the data driven load prediction and the physical based one are consistent or not, so it can find if something is wrong in load prediction procedure, (3) it has ability to adjust load prediction in real-time against sudden change of model parameters and environmental conditions. The proposed method is evaluated with real operation data of an existing building, and the improvement of load prediction performance is illustrated.
ERIC Educational Resources Information Center
Lee, Aimee T.; Hairston, Rosalina V.; Thames, Rachel; Lawrence, Tonya; Herron, Sherry S.
2002-01-01
Describes the Lateblight computer simulation implemented in the general biology laboratory and science methods course for elementary teachers to reinforce the processes of science and allow students to engage, explore, explain, elaborate, and evaluate the methods of building concepts in science. (Author/KHR)
Experiments in evaluation capacity building: Enhancing brain disorders research impact in Ontario.
Nylen, Kirk; Sridharan, Sanjeev
2017-05-08
This paper is the introductory paper on a forum on evaluation capacity building for enhancing impacts of research on brain disorders. It describes challenges and opportunities of building evaluation capacity among community-based organizations in Ontario involved in enhancing brain health and supporting people living with a brain disorder. Using an example of a capacity building program called the "Evaluation Support Program", which is run by the Ontario Brain Institute, this forum discusses multiple themes including evaluation capacity building, evaluation culture and evaluation methodologies appropriate for evaluating complex community interventions. The goal of the Evaluation Support Program is to help community-based organizations build the capacity to demonstrate the value that they offer in order to improve, sustain, and spread their programs and activities. One of the features of this forum is that perspectives on the Evaluation Support Program are provided by multiple stakeholders, including the community-based organizations, evaluation team members involved in capacity building, thought leaders in the fields of evaluation capacity building and evaluation culture, and the funders. Copyright © 2017. Published by Elsevier Ltd.
Thermal dynamic simulation of wall for building energy efficiency under varied climate environment
NASA Astrophysics Data System (ADS)
Wang, Xuejin; Zhang, Yujin; Hong, Jing
2017-08-01
Aiming at different kind of walls in five cities of different zoning for thermal design, using thermal instantaneous response factors method, the author develops software to calculation air conditioning cooling load temperature, thermal response factors, and periodic response factors. On the basis of the data, the author gives the net work analysis about the influence of dynamic thermal of wall on air-conditioning load and thermal environment in building of different zoning for thermal design regional, and put forward the strategy how to design thermal insulation and heat preservation wall base on dynamic thermal characteristic of wall under different zoning for thermal design regional. And then provide the theory basis and the technical references for the further study on the heat preservation with the insulation are in the service of energy saving wall design. All-year thermal dynamic load simulating and energy consumption analysis for new energy-saving building is very important in building environment. This software will provide the referable scientific foundation for all-year new thermal dynamic load simulation, energy consumption analysis, building environment systems control, carrying through farther research on thermal particularity and general particularity evaluation for new energy -saving walls building. Based on which, we will not only expediently design system of building energy, but also analyze building energy consumption and carry through scientific energy management. The study will provide the referable scientific foundation for carrying through farther research on thermal particularity and general particularity evaluation for new energy saving walls building.
NASA Astrophysics Data System (ADS)
Epackachi, S.; Esmaili, O.; Mirghaderi, S. R.; Taheri, A. A.
2008-07-01
Tehran tower is a 56 story reinforced concrete tall building consisting of three wings with identical plan dimensions each approximately 48 meters by 22 meters. The three wings are at 120 degree from each other and have no expansions/seismic Joints. This paper contains the consideration of the retrofitting of the Tehran tower based on the findings of an exhaustive investigation of the nonlinear performance evaluation efforts. It has tried to show the procedure followed, methodologies utilized, and the results obtained for life-safety and collapse-prevention evaluation of the building. More over the weak zones of the structure due to analysis results are introduced and appropriate retrofit technique for satisfaction related life-safety and collapse-prevention criteria is presented. Actually in this project to improve the local behavior of coupling panels which are located regularly in main walls and definitely have been recognized as the most vulnerable structural elements, making use of steel plates which are connected to concrete members by chemical anchors has been used as the best retrofitting method for this case. Therefore in the final section of this paper it has been tried to explain the professional practical method utilized to perform the mentioned retrofitting project.
Hydraulic Control Method for Heating Systems of High-Rise Buildings
NASA Astrophysics Data System (ADS)
Makarov, D.; Chernenkov, V.; Likhachev, I.
2017-11-01
The following article reflects the ideas of possibility to increase energy efficiency of heating systems in high-rise buildings. The article also includes the principle ways of high-rise building heating systems operation as well as traditional engineering decisions aimed at the elimination of the increased pressure effect in heaters. The main disadvantages of such decisions are also presented for the reader. Moreover, the article offers the way of operation for the above-mentioned systems together with the equipment that implements this operation. An economic impact from such energy-saving technology application has been also evaluated.
Airside HVAC BESTEST: HVAC Air-Distribution System Model Test Cases for ASHRAE Standard 140
DOE Office of Scientific and Technical Information (OSTI.GOV)
Judkoff, Ronald; Neymark, Joel; Kennedy, Mike D.
This paper summarizes recent work to develop new airside HVAC equipment model analytical verification test cases for ANSI/ASHRAE Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. The analytical verification test method allows comparison of simulation results from a wide variety of building energy simulation programs with quasi-analytical solutions, further described below. Standard 140 is widely cited for evaluating software for use with performance-path energy efficiency analysis, in conjunction with well-known energy-efficiency standards including ASHRAE Standard 90.1, the International Energy Conservation Code, and other international standards. Airside HVAC Equipment is a common area ofmore » modelling not previously explicitly tested by Standard 140. Integration of the completed test suite into Standard 140 is in progress.« less
Wind/seismic comparisons for upgrading existing structures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giller, R.A.
1989-10-01
This paper depicts the analysis procedures and methods used to evaluate three existing building structures for extreme wind loads. The three structures involved in this evaluation are located at the US Department of Energy's Hanford Site near Richland, Washington. This site is characterized by open flat grassland with few surrounding obstructions and has extreme winds in lieu of tornados as a design basis accident condition. This group of buildings represents a variety of construction types, including a concrete stack, a concrete load-bearing wall structure, and a rigid steel-frame building. The three structures included in this group have recently been evaluatedmore » for response to the design basis earthquake that included non-linear time history effects. The resulting loads and stresses from the wind analyses were compared to the loads and stresses resulting from seismic analyses. This approach eliminated the need to prepare additional capacity calculations that were already contained in the seismic evaluations. 4 refs., 5 figs., 5 tabs.« less
ICT for smart evaluation of vernacular architecture in a stilt-house village
NASA Astrophysics Data System (ADS)
Almeida, Filipa; Virtudes, Ana Lídia
2016-12-01
Vernacular architecture typologies, such as wooden stilt-houses, have been threatened by the vulnerability to conservation status degradation. This problem is not an exception in Portugal, where the few remaining examples have been neglected, with the disappearance or abandonment of almost all buildings, damaging architectural and urban spatial features. This legacy is rapidly disappearing, weakening the European cultural map. This research presents the results from a smart evaluation method using an ICT (information and communication technology) platform designed for the smart evaluation of wooden stilt-houses, considering their conservation status. This platform was used in the five remaining stilthouse villages still existing in Portugal including about 90 buildings and 300 inhabitants, located along Tagus river banks. This article refers to one of these case studies, the village of Escaroupim, which was chosen because it is the most urban space in between all of them. On one hand, the results are an exhaustive survey of vernacular buildings, useful as guideline for spatial strategies and instruments to protect this legacy. On the other hand, it can be used in other similar wooden buildings, to check their conservation status and therefore to define best rehabilitation actions.
Cost Savings Threshold Analysis of a Capacity-Building Program for HIV Prevention Organizations
ERIC Educational Resources Information Center
Dauner, Kim Nichols; Oglesby, Willie H.; Richter, Donna L.; LaRose, Christopher M.; Holtgrave, David R.
2008-01-01
Although the incidence of HIV each year remains steady, prevention funding is increasingly competitive. Programs need to justify costs in terms of evaluation outcomes, including economic ones. Threshold analyses set performance standards to determine program effectiveness relative to that threshold. This method was used to evaluate the potential…
Using Oral Exams to Assess Communication Skills in Business Courses
ERIC Educational Resources Information Center
Burke-Smalley, Lisa A.
2014-01-01
Business, like many other fields in higher education, continues to rely largely on conventional testing methods for assessing student learning. In the current article, another evaluation approach--the oral exam--is examined as a means for building and evaluating the professional communication and oral dialogue skills needed and utilized by…
ERIC Educational Resources Information Center
Zepeda, Sally J.; Lanoue, Philip D.; Price, Noris F.; Jimenez, Albert M.
2014-01-01
The article examines the tensions one superintendent in the USA experienced as he evaluated principals in a high-stakes environment that had undergone numerous transformations at the central office. Using qualitative methods, primarily, shadowing techniques, observations and debriefing, the following tensions emerged and were examined in light of…
DOT National Transportation Integrated Search
2006-10-01
Missourian strata were studied in eastern Kansas to evaluate the build-and-fill controls on strata deposited in association with high-amplitude glacioeustatic sea-level fluctuations. Results from this study show that creation of relief in high-freque...
Research status and evaluation system of heat source evaluation method for central heating
NASA Astrophysics Data System (ADS)
Sun, Yutong; Qi, Junfeng; Cao, Yi
2018-02-01
The central heating boiler room is a regional heat source heating center. It is also a kind of the urban environment pollution, it is an important section of building energy efficiency. This article through to the evaluation method of central heating boiler room and overviews of the researches during domestic and overseas, summarized the main influence factors affecting energy consumption of industrial boiler under the condition of stable operation. According to the principle of establishing evaluation index system. We can find that is great significance in energy saving and environmental protection for the content of the evaluation index system of the centralized heating system.
NASA Astrophysics Data System (ADS)
Hannoudi, Loay Akram; Lauring, Michael; Christensen, Jørgen Erik
2017-09-01
This paper is concerned with using solar panels as high-tech cladding materials on multi-angled facades for office buildings. The energy produced by the solar panels will be consumed inside the office rooms by cooling compressors, ventilation, lighting and office equipment. Each multi-angled facade unit is directed into two different orientations on a vertical axis (right and left), but not tilted up and down. The different facade orientations will optimize the use of solar radiation to produce the needed energy from the solar panels when placing them on the parapets of these facades. In this regard, four scenarios with different facade configurations and orientations are evaluated and discussed. The method for the simulations and calculations depends on two main programs: first, IDA ICE program to calculate the energy consumption and evaluate the indoor climate of the building; and second, PVBAT to calculate the cost of the electricity produced by the solar panels and evaluate the total amount of energy produced from these panels along with the ratio to the energy bought directly from the electricity grid. There is also an environmental evaluation for the system by calculating the CO2 emissions in the different scenarios.
Beyond the buildingcentric approach: A vision for an integrated evaluation of sustainable buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Conte, Emilia, E-mail: conte@poliba.it; Monno, Valeria, E-mail: vmonno@poliba.it
2012-04-15
The available sustainable building evaluation systems have produced a new environmental design paradigm. However, there is an increasing need to overcome the buildingcentric approach of these systems, in order to further exploit their innovate potential for sustainable building practices. The paper takes this challenge by developing a cross-scale evaluation approach focusing on the reliability of sustainable building design solutions for the context in which the building is situated. An integrated building-urban evaluation model is proposed based on the urban matrix, which is a conceptualisation of the built environment as a social-ecological system. The model aims at evaluating the sustainability ofmore » a building considering it as an active entity contributing to the resilience of the urban matrix. Few holistic performance indicators are used for evaluating such contribution, so expressing the building reliability. The discussion on the efficacy of the model shows that it works as a heuristic tool, supporting the acquisition of a better insight into the complexity which characterises the relationships between the building and the built environment sustainability. Shading new lights on the meaning of sustainable buildings, the model can play a positive role in innovating sustainable building design practices, thus complementing current evaluation systems. - Highlights: Black-Right-Pointing-Pointer We model an integrated building-urban evaluation approach. Black-Right-Pointing-Pointer The urban matrix represents the social-ecological functioning of the urban context. Black-Right-Pointing-Pointer We introduce the concept of reliability to evaluate sustainable buildings. Black-Right-Pointing-Pointer Holistic indicators express the building reliability. Black-Right-Pointing-Pointer The evaluation model works as heuristic tool and complements other tools.« less
Süß, W; Nickel, S; Wolf, K; Trojan, A
2015-09-01
In 2005 the local health authority Hamburg-Eimsbüttel developed a prevention programme for the disadvantaged quarter "Lenzsiedlung" which has been implemented by the stakeholders committee "Round Table Lenzgesund" and other partners led by the health authority. The Department of Medical Sociology and Health Economics of the University Medical Centre had taken on the accompanying analysis and long-term evaluation with a mixture of qualitative and quantitative methods for health reporting and evaluation and a new instrument for measuring capacity building in the quarter (KEQ). © Georg Thieme Verlag KG Stuttgart · New York.
DOT National Transportation Integrated Search
2007-05-01
This paper evaluates impact of various I-15 reconstruction closure scenarios on the travelers in Ogden area. The purpose of the research was to investigate impact of the scenarios and facilitate decision about future maintenance of traffic during the...
The method of selecting an integrated development territory for the high-rise unique constructions
NASA Astrophysics Data System (ADS)
Sheina, Svetlana; Shevtsova, Elina; Sukhinin, Alexander; Priss, Elena
2018-03-01
On the basis of data provided by the Department of architecture and urban planning of the city of Rostov-on-don, the problem of the choice of the territory for complex development that will be in priority for the construction of high-rise and unique buildings is solved. The objective of the study was the development of a methodology for selection of the area and the implementation of the proposed method on the example of evaluation of four-territories complex development. The developed method along with standard indicators of complex evaluation considers additional indicators that assess the territory from the position of high-rise unique building. The final result of the study is the rankings of the functional priority areas that takes into account the construction of both residential and public and business objects of unique high-rise construction. The use of the developed methodology will allow investors and customers to assess the investment attractiveness of the future unique construction project on the proposed site.
NASA Astrophysics Data System (ADS)
Chen, C.; Gong, W.; Hu, Y.; Chen, Y.; Ding, Y.
2017-05-01
The automated building detection in aerial images is a fundamental problem encountered in aerial and satellite images analysis. Recently, thanks to the advances in feature descriptions, Region-based CNN model (R-CNN) for object detection is receiving an increasing attention. Despite the excellent performance in object detection, it is problematic to directly leverage the features of R-CNN model for building detection in single aerial image. As we know, the single aerial image is in vertical view and the buildings possess significant directional feature. However, in R-CNN model, direction of the building is ignored and the detection results are represented by horizontal rectangles. For this reason, the detection results with horizontal rectangle cannot describe the building precisely. To address this problem, in this paper, we proposed a novel model with a key feature related to orientation, namely, Oriented R-CNN (OR-CNN). Our contributions are mainly in the following two aspects: 1) Introducing a new oriented layer network for detecting the rotation angle of building on the basis of the successful VGG-net R-CNN model; 2) the oriented rectangle is proposed to leverage the powerful R-CNN for remote-sensing building detection. In experiments, we establish a complete and bran-new data set for training our oriented R-CNN model and comprehensively evaluate the proposed method on a publicly available building detection data set. We demonstrate State-of-the-art results compared with the previous baseline methods.
Life Cycle Assessment of Wall Systems
NASA Astrophysics Data System (ADS)
Ramachandran, Sriranjani
Natural resource depletion and environmental degradation are the stark realities of the times we live in. As awareness about these issues increases globally, industries and businesses are becoming interested in understanding and minimizing the ecological footprints of their activities. Evaluating the environmental impacts of products and processes has become a key issue, and the first step towards addressing and eventually curbing climate change. Additionally, companies are finding it beneficial and are interested in going beyond compliance using pollution prevention strategies and environmental management systems to improve their environmental performance. Life-cycle Assessment (LCA) is an evaluative method to assess the environmental impacts associated with a products' life-cycle from cradle-to-grave (i.e. from raw material extraction through to material processing, manufacturing, distribution, use, repair and maintenance, and finally, disposal or recycling). This study focuses on evaluating building envelopes on the basis of their life-cycle analysis. In order to facilitate this analysis, a small-scale office building, the University Services Building (USB), with a built-up area of 148,101 ft2 situated on ASU campus in Tempe, Arizona was studied. The building's exterior envelope is the highlight of this study. The current exterior envelope is made of tilt-up concrete construction, a type of construction in which the concrete elements are constructed horizontally and tilted up, after they are cured, using cranes and are braced until other structural elements are secured. This building envelope is compared to five other building envelope systems (i.e. concrete block, insulated concrete form, cast-in-place concrete, steel studs and curtain wall constructions) evaluating them on the basis of least environmental impact. The research methodology involved developing energy models, simulating them and generating changes in energy consumption due to the above mentioned envelope types. Energy consumption data, along with various other details, such as building floor area, areas of walls, columns, beams etc. and their material types were imported into Life-Cycle Assessment software called ATHENA impact estimator for buildings. Using this four-stepped LCA methodology, the results showed that the Steel Stud envelope performed the best and less environmental impact compared to other envelope types. This research methodology can be applied to other building typologies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Joyce Jihyun; Yin, Rongxin; Kiliccote, Sila
Open Automated Demand Response (OpenADR), an XML-based information exchange model, is used to facilitate continuous price-responsive operation and demand response participation for large commercial buildings in New York who are subject to the default day-ahead hourly pricing. We summarize the existing demand response programs in New York and discuss OpenADR communication, prioritization of demand response signals, and control methods. Building energy simulation models are developed and field tests are conducted to evaluate continuous energy management and demand response capabilities of two commercial buildings in New York City. Preliminary results reveal that providing machine-readable prices to commercial buildings can facilitate bothmore » demand response participation and continuous energy cost savings. Hence, efforts should be made to develop more sophisticated algorithms for building control systems to minimize customer's utility bill based on price and reliability information from the electricity grid.« less
Detection of collapsed buildings from lidar data due to the 2016 Kumamoto earthquake in Japan
NASA Astrophysics Data System (ADS)
Moya, Luis; Yamazaki, Fumio; Liu, Wen; Yamada, Masumi
2018-01-01
The 2016 Kumamoto earthquake sequence was triggered by an Mw 6.2 event at 21:26 on 14 April. Approximately 28 h later, at 01:25 on 16 April, an Mw 7.0 event (the mainshock) followed. The epicenters of both events were located near the residential area of Mashiki and affected the region nearby. Due to very strong seismic ground motion, the earthquake produced extensive damage to buildings and infrastructure. In this paper, collapsed buildings were detected using a pair of digital surface models (DSMs), taken before and after the 16 April mainshock by airborne light detection and ranging (lidar) flights. Different methods were evaluated to identify collapsed buildings from the DSMs. The change in average elevation within a building footprint was found to be the most important factor. Finally, the distribution of collapsed buildings in the study area was presented, and the result was consistent with that of a building damage survey performed after the earthquake.
ACMV Energy Analysis for Academic Building: A Case Study
NASA Astrophysics Data System (ADS)
Hywel, R.; Tee, B. T.; Arifin, M. Y.; Tan, C. F.; Gan, C. K.; Chong, CT
2015-09-01
Building energy audit examines the ways actual energy consumption is currently used in the facility, in the case of a completed and occupied building and identifies some alternatives to reduce current energy usage. Implementation of energy audit are practically used to analyze energy consumption pattern, monitoring on how the energy used varies with time in the building, how the system element interrelate, and study the effect of external environment towards building. In this case study, a preliminary energy audit is focusing on Air-Conditioning & Mechanical Ventilation (ACMV) system which reportedly consumed 40% of the total energy consumption in typical building. It is also the main system that provides comfortable and healthy environment for the occupants. The main purpose of this study is to evaluate the current ACMV system performance, energy optimization and identifying the energy waste on UTeM's academic building. To attain this, the preliminary data is collected and then analyzed. Based on the data, economic analysis will be determined before cost-saving methods are being proposed.
Aliu, Oluseyi; Corlew, Scott D; Heisler, Michele E; Pannucci, Christopher J; Chung, Kevin C
2014-01-01
Surgical volunteer organizations (SVOs) focus considerable resources on addressing the backlog of cases in low-resource countries. This model of service may perpetuate dependency. Efforts should focus on models that establish independence in providing surgical care. Independence could be achieved through surgical capacity building. However, there has been scant discussion in literature on SVO involvement in surgical capacity building. Using qualitative methods, we evaluated the perspectives of surgeons with extensive volunteer experience in low-resource countries. We collected data through in-depth interviews that centered on SVOs using task shifting as a tool for surgical capacity building. Some of the key themes from our analysis include the ethical ramifications of task shifting, the challenges of addressing technical and clinical education in capacity building for low-resource settings, and the allocation of limited volunteer resources toward surgical capacity building. These themes will be the foundation of subsequent studies that will focus on other stakeholders in surgical capacity building including host communities and SVO administrators.
Development of an Interactive Social Media Tool for Parents with Concerns about Vaccines
ERIC Educational Resources Information Center
Shoup, Jo Ann; Wagner, Nicole M.; Kraus, Courtney R.; Narwaney, Komal J.; Goddard, Kristin S.; Glanz, Jason M.
2015-01-01
Objective: Describe a process for designing, building, and evaluating a theory-driven social media intervention tool to help reduce parental concerns about vaccination. Method: We developed an interactive web-based tool using quantitative and qualitative methods (e.g., survey, focus groups, individual interviews, and usability testing). Results:…
Dynamic evaluation of airflow rates for a variable air volume system serving an open-plan office.
Mai, Horace K W; Chan, Daniel W T; Burnett, John
2003-09-01
In a typical air-conditioned office, the thermal comfort and indoor air quality are sustained by delivering the amount of supply air with the correct proportion of outdoor air to the breathing zone. However, in a real office, it is not easy to measure these airflow rates supplied to space, especially when the space is served by a variable air volume (VAV) system. The most accurate method depends on what is being measured, the details of the building and types of ventilation system. The constant concentration tracer gas method as a means to determine ventilation system performance, however, this method becomes more complicated when the air, including the tracer gas is allowed to recirculate. An accurate measurement requires significant resource support in terms of instrumentation set up and also professional interpretation. This method deters regular monitoring of the performance of an airside systems by building managers, and hence the indoor environmental quality, in terms of thermal comfort and indoor air quality, may never be satisfactory. This paper proposes a space zone model for the calculation of all the airflow parameters based on tracer gas measurements, including flow rates of outdoor air, VAV supply, return space, return and exfiltration. Sulphur hexafluoride (SF6) and carbon dioxide (CO2) are used as tracer gases. After using both SF6 and CO2, the corresponding results provide a reference to justify the acceptability of using CO2 as the tracer gas. The validity of using CO2 has the significance that metabolic carbon dioxide can be used as a means to evaluate real time airflow rates. This approach provides a practical protocol for building managers to evaluate the performance of airside systems.
Method for Smoke Spread Testing of Large Premises
NASA Astrophysics Data System (ADS)
Walmerdahl, P.; Werling, P.
2001-11-01
A method for performing non-destructive smoke spread tests has been developed, tested and applied to several existing buildings. Burning methanol in different size steel trays cooled by water generates the heat source. Several tray sizes are available to cover fire sources up to nearly 1MW. The smoke is supplied by means of a suitable number of smoke generators that produce a smoke, which can be described as a non-toxic aerosol. The advantage of the method is that it provides a means for performing non-destructive tests in already existing buildings and other installations for the purpose of evaluating the functionality and design of the active fire protection measures such as smoke extraction systems, etc. In the report, the method is described in detail and experimental data from the try-out of the method are also presented in addition to a discussion on applicability and flexibility of the method.
Keynejad, Roxanne; Semrau, Maya; Toynbee, Mark; Evans-Lacko, Sara; Lund, Crick; Gureje, Oye; Ndyanabangi, Sheila; Courtin, Emilie; Abdulmalik, Jibril O; Alem, Atalay; Fekadu, Abebaw; Thornicroft, Graham; Hanlon, Charlotte
2016-10-21
Little is known about the interventions required to build the capacity of mental health policy-makers and planners in low- and middle-income countries (LMICs). We conducted a systematic review with the primary aim of identifying and synthesizing the evidence base for building the capacity of policy-makers and planners to strengthen mental health systems in LMICs. We searched MEDLINE, Embase, PsycINFO, Web of Knowledge, Web of Science, Scopus, CINAHL, LILACS, ScieELO, Google Scholar and Cochrane databases for studies reporting evidence, experience or evaluation of capacity-building of policy-makers, service planners or managers in mental health system strengthening in LMICs. Reports in English, Spanish, Portuguese, French or German were included. Additional papers were identified by hand-searching references and contacting experts and key informants. Database searches yielded 2922 abstracts and 28 additional papers were identified. Following screening, 409 full papers were reviewed, of which 14 fulfilled inclusion criteria for the review. Data were extracted from all included papers and synthesized into a narrative review. Only a small number of mental health system-related capacity-building interventions for policy-makers and planners in LMICs were described. Most models of capacity-building combined brief training with longer term mentorship, dialogue and/or the establishment of networks of support. However, rigorous research and evaluation methods were largely absent, with studies being of low quality, limiting the potential to separate mental health system strengthening outcomes from the effects of associated contextual factors. This review demonstrates the need for partnership approaches to building the capacity of mental health policy-makers and planners in LMICs, assessed rigorously against pre-specified conceptual frameworks and hypotheses, utilising longitudinal evaluation and mixed quantitative and qualitative approaches.
High-throughput screening for bioactive components from traditional Chinese medicine.
Zhu, Yanhui; Zhang, Zhiyun; Zhang, Meng; Mais, Dale E; Wang, Ming-Wei
2010-12-01
Throughout the centuries, traditional Chinese medicine has been a rich resource in the development of new drugs. Modern drug discovery, which relies increasingly on automated high throughput screening and quick hit-to-lead development, however, is confronted with the challenges of the chemical complexity associated with natural products. New technologies for biological screening as well as library building are in great demand in order to meet the requirements. Here we review the developments in these techniques under the perspective of their applicability in natural product drug discovery. Methods in library building, component characterizing, biological evaluation, and other screening methods including NMR and X-ray diffraction are discussed.
Crocker, Jonny; Shields, Katherine F; Venkataramanan, Vidya; Saywell, Darren; Bartram, Jamie
2016-10-01
Training and capacity building are long established critical components of global water, sanitation, and hygiene (WaSH) policies, strategies, and programs. Expanding capacity building support for WaSH in developing countries is one of the targets of the Sustainable Development Goals. There are many training evaluation methods and tools available. However, training evaluations in WaSH have been infrequent, have often not utilized these methods and tools, and have lacked rigor. We developed a conceptual framework for evaluating training in WaSH by reviewing and adapting concepts from literature. Our framework includes three target outcomes: learning, individual performance, and improved programming; and two sets of influences: trainee and context factors. We applied the framework to evaluate a seven-month community-led total sanitation (CLTS) management training program delivered to 42 government officials in Kenya from September 2013 to May 2014. Trainees were given a pre-training questionnaire and were interviewed at two weeks and seven months after initial training. We qualitatively analyzed the data using our conceptual framework. The training program resulted in trainees learning the CLTS process and new skills, and improving their individual performance through application of advocacy, partnership, and supervision soft skills. The link from trainees' performance to improved programming was constrained by resource limitations and pre-existing rigidity of trainees' organizations. Training-over-time enhanced outcomes and enabled trainees to overcome constraints in their work. Training in soft skills is relevant to managing public health programs beyond WaSH. We make recommendations on how training programs can be targeted and adapted to improve outcomes. Our conceptual framework can be used as a tool both for planning and evaluating training programs in WaSH. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
ERIC Educational Resources Information Center
Tai, Joanna Hong-Meng; Canny, Benedict J.; Haines, Terry P.; Molloy, Elizabeth K.
2016-01-01
This study explored the contribution of peer-assisted learning (PAL) in the development of evaluative judgement capacity; the ability to understand work quality and apply those standards to appraising performance. The study employed a mixed methods approach, collecting self-reported survey data, observations of, and reflective interviews with, the…
ERIC Educational Resources Information Center
Jaffery, Rose; Johnson, Austin H.; Bowler, Mark C.; Riley-Tillman, T. Chris; Chafouleas, Sandra M.; Harrison, Sayward E.
2015-01-01
To date, rater accuracy when using Direct Behavior Rating (DBR) has been evaluated by comparing DBR-derived data to scores yielded through systematic direct observation. The purpose of this study was to evaluate an alternative method for establishing comparison scores using expert-completed DBR alongside best practices in consensus building…
ERIC Educational Resources Information Center
Cole, Bruce Kevin
2012-01-01
Evaluations of Public-Private Partnership arrangements as alternatives to traditional government procurement methods for the delivery of public infrastructure projects have been anecdotal at best. This paper proposes a framework to evaluate a public university's infrastructure asset management performance and a specific measure based on a new…
The State as Community in Community-based Participatory Research
Goold, Susan Dorr; Rowe, Zachary; Szymecko, Lisa; Coombe, Chris; Danis, Marion; Hammad, Adnan; Calhoun, Karen; Salman, Cengiz
2017-01-01
Background Community-based participatory research (CBPR) typically defines communities by geography, ethnicity, shared health needs, or some combination. Objectives We describe a CBPR project aiming to engage diverse minority and underserved communities throughout Michigan in deliberations about health research priorities. Methods A Steering Committee (SC) with 15 members from minority and underserved communities, and 4 members from research organizations led the project, with the help of regional advisory groups (RAGs) formed at the SC’s request. Evaluation of the SC used questionnaires, focused group discussion, and review of SC meetings to describe engagement, partnership, and communication. Lessons Learned An academic-community partnership with a diverse, dispersed and broadly defined community found value in RAGs, dedicated academic staff, face-to-face meetings, varied communication modalities, capacity building tailored to varying levels of CBPR experience, and ongoing evaluation. Conclusions A geographically and culturally diverse partnership presents challenges and opportunities in representativeness, relationship building, capacity building, and communication. PMID:28569676
Evaluation of biotechnologies for flexible pavement applications : final report.
DOT National Transportation Integrated Search
2016-12-01
With solid data from environmental scientists supporting climate change there has been a strong push in the industry to look for alternative green or environmentally friendly methods to keep building and maintaining our infrastructure. This col...
NASA Astrophysics Data System (ADS)
Kaskhedikar, Apoorva Prakash
According to the U.S. Energy Information Administration, commercial buildings represent about 40% of the United State's energy consumption of which office buildings consume a major portion. Gauging the extent to which an individual building consumes energy in excess of its peers is the first step in initiating energy efficiency improvement. Energy Benchmarking offers initial building energy performance assessment without rigorous evaluation. Energy benchmarking tools based on the Commercial Buildings Energy Consumption Survey (CBECS) database are investigated in this thesis. This study proposes a new benchmarking methodology based on decision trees, where a relationship between the energy use intensities (EUI) and building parameters (continuous and categorical) is developed for different building types. This methodology was applied to medium office and school building types contained in the CBECS database. The Random Forest technique was used to find the most influential parameters that impact building energy use intensities. Subsequently, correlations which were significant were identified between EUIs and CBECS variables. Other than floor area, some of the important variables were number of workers, location, number of PCs and main cooling equipment. The coefficient of variation was used to evaluate the effectiveness of the new model. The customization technique proposed in this thesis was compared with another benchmarking model that is widely used by building owners and designers namely, the ENERGY STAR's Portfolio Manager. This tool relies on the standard Linear Regression methods which is only able to handle continuous variables. The model proposed uses data mining technique and was found to perform slightly better than the Portfolio Manager. The broader impacts of the new benchmarking methodology proposed is that it allows for identifying important categorical variables, and then incorporating them in a local, as against a global, model framework for EUI pertinent to the building type. The ability to identify and rank the important variables is of great importance in practical implementation of the benchmarking tools which rely on query-based building and HVAC variable filters specified by the user.
Automated Measurement and Verification and Innovative Occupancy Detection Technologies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Price, Phillip; Bruce, Nordman; Piette, Mary Ann
In support of DOE’s sensors and controls research, the goal of this project is to move toward integrated building to grid systems by building on previous work to develop and demonstrate a set of load characterization measurement and evaluation tools that are envisioned to be part of a suite of applications for transactive efficient buildings, built upon data-driven load characterization and prediction models. This will include the ability to include occupancy data in the models, plus data collection and archival methods to include different types of occupancy data with existing networks and a taxonomy for naming these data within amore » Volttron agent platform.« less
ERIC Educational Resources Information Center
Ahtee, Maija, Ed.; And Others
The main purpose of this symposium was to find new ideas and resources for the evaluation and improvement of physics education on all levels. The papers included in this document are entitled: (1) "Quality of Physics Teaching Through Building Models and Advancing Research Skills"; (2) "Evaluation of Physics Education in Terms of Its…
A model for the sustainable selection of building envelope assemblies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huedo, Patricia, E-mail: huedo@uji.es; Mulet, Elena, E-mail: emulet@uji.es; López-Mesa, Belinda, E-mail: belinda@unizar.es
2016-02-15
The aim of this article is to define an evaluation model for the environmental impacts of building envelopes to support planners in the early phases of materials selection. The model is intended to estimate environmental impacts for different combinations of building envelope assemblies based on scientifically recognised sustainability indicators. These indicators will increase the amount of information that existing catalogues show to support planners in the selection of building assemblies. To define the model, first the environmental indicators were selected based on the specific aims of the intended sustainability assessment. Then, a simplified LCA methodology was developed to estimate themore » impacts applicable to three types of dwellings considering different envelope assemblies, building orientations and climate zones. This methodology takes into account the manufacturing, installation, maintenance and use phases of the building. Finally, the model was validated and a matrix in Excel was created as implementation of the model. - Highlights: • Method to assess the envelope impacts based on a simplified LCA • To be used at an earlier phase than the existing methods in a simple way. • It assigns a score by means of known sustainability indicators. • It estimates data about the embodied and operating environmental impacts. • It compares the investment costs with the costs of the consumed energy.« less
NASA Astrophysics Data System (ADS)
Radomski, Bartosz; Ćwiek, Barbara; Mróz, Tomasz M.
2017-11-01
The paper presents multicriteria decision aid analysis of the choice of PV installation providing electric energy to a public utility building. From the energy management point of view electricity obtained by solar radiation has become crucial renewable energy source. Application of PV installations may occur a profitable solution from energy, economic and ecologic point of view for both existing and newly erected buildings. Featured variants of PV installations have been assessed by multicriteria analysis based on ANP (Analytic Network Process) method. Technical, economical, energy and environmental criteria have been identified as main decision criteria. Defined set of decision criteria has an open character and can be modified in the dialog process between the decision-maker and the expert - in the present case, an expert in planning of development of energy supply systems. The proposed approach has been used to evaluate three variants of PV installation acceptable for existing educational building located in Poznań, Poland - the building of Faculty of Chemical Technology, Poznań University of Technology. Multi-criteria analysis based on ANP method and the calculation software Super Decisions has proven to be an effective tool for energy planning, leading to the indication of the recommended variant of PV installation in existing and newly erected public buildings. Achieved results show prospects and possibilities of rational renewable energy usage as complex solution to public utility buildings.
Wave Dynamic Analysis of the Seismic Response of a Reinforced Concrete Building
DOE Office of Scientific and Technical Information (OSTI.GOV)
Astroza, Rodrigo; Saragoni, G. Rodolfo
2008-07-08
This paper evaluates the response of the seven-story instrumented building, Holiday Inn Hotel, during the 1994 Northridge earthquake through the wave propagation dynamic analysis. The building has been instrumented during other earthquakes, the most important of these was the 1971 San Fernando earthquake, where the building was located only 22 [km] from the epicenter and didn't showing structural damage. From the accelerograms analysis is detected the propagation of Rayleigh and soil waves in the building, where the first has a polarized particle motion on a vertical plane and the second has a coupled particle motion in the horizontal plane. Bothmore » waves impose their frequencies to the building response, whose fundamental frequency (1.4 [Hz] according to ambient vibration test) is less than the frequencies of the identified waves. Due to the impact that these observations have in the seismic design of buildings, as a first attempt, a simple method is proposed to estimate the drift produced by the propagation of a Rayleigh wave in buildings.« less
Thermal Insulating Concrete Wall Panel Design for Sustainable Built Environment
Zhou, Ao; Wong, Kwun-Wah
2014-01-01
Air-conditioning system plays a significant role in providing users a thermally comfortable indoor environment, which is a necessity in modern buildings. In order to save the vast energy consumed by air-conditioning system, the building envelopes in envelope-load dominated buildings should be well designed such that the unwanted heat gain and loss with environment can be minimized. In this paper, a new design of concrete wall panel that enhances thermal insulation of buildings by adding a gypsum layer inside concrete is presented. Experiments have been conducted for monitoring the temperature variation in both proposed sandwich wall panel and conventional concrete wall panel under a heat radiation source. For further understanding the thermal effect of such sandwich wall panel design from building scale, two three-story building models adopting different wall panel designs are constructed for evaluating the temperature distribution of entire buildings using finite element method. Both the experimental and simulation results have shown that the gypsum layer improves the thermal insulation performance by retarding the heat transfer across the building envelopes. PMID:25177718
Thermal insulating concrete wall panel design for sustainable built environment.
Zhou, Ao; Wong, Kwun-Wah; Lau, Denvid
2014-01-01
Air-conditioning system plays a significant role in providing users a thermally comfortable indoor environment, which is a necessity in modern buildings. In order to save the vast energy consumed by air-conditioning system, the building envelopes in envelope-load dominated buildings should be well designed such that the unwanted heat gain and loss with environment can be minimized. In this paper, a new design of concrete wall panel that enhances thermal insulation of buildings by adding a gypsum layer inside concrete is presented. Experiments have been conducted for monitoring the temperature variation in both proposed sandwich wall panel and conventional concrete wall panel under a heat radiation source. For further understanding the thermal effect of such sandwich wall panel design from building scale, two three-story building models adopting different wall panel designs are constructed for evaluating the temperature distribution of entire buildings using finite element method. Both the experimental and simulation results have shown that the gypsum layer improves the thermal insulation performance by retarding the heat transfer across the building envelopes.
Proposal of a method for evaluating tsunami risk using response-surface methodology
NASA Astrophysics Data System (ADS)
Fukutani, Y.
2017-12-01
Information on probabilistic tsunami inundation hazards is needed to define and evaluate tsunami risk. Several methods for calculating these hazards have been proposed (e.g. Løvholt et al. (2012), Thio (2012), Fukutani et al. (2014), Goda et al. (2015)). However, these methods are inefficient, and their calculation cost is high, since they require multiple tsunami numerical simulations, therefore lacking versatility. In this study, we proposed a simpler method for tsunami risk evaluation using response-surface methodology. Kotani et al. (2016) proposed an evaluation method for the probabilistic distribution of tsunami wave-height using a response-surface methodology. We expanded their study and developed a probabilistic distribution of tsunami inundation depth. We set the depth (x1) and the slip (x2) of an earthquake fault as explanatory variables and tsunami inundation depth (y) as an object variable. Subsequently, tsunami risk could be evaluated by conducting a Monte Carlo simulation, assuming that the generation probability of an earthquake follows a Poisson distribution, the probability distribution of tsunami inundation depth follows the distribution derived from a response-surface, and the damage probability of a target follows a log normal distribution. We applied the proposed method to a wood building located on the coast of Tokyo Bay. We implemented a regression analysis based on the results of 25 tsunami numerical calculations and developed a response-surface, which was defined as y=ax1+bx2+c (a:0.2615, b:3.1763, c=-1.1802). We assumed proper probabilistic distribution for earthquake generation, inundation height, and vulnerability. Based on these probabilistic distributions, we conducted Monte Carlo simulations of 1,000,000 years. We clarified that the expected damage probability of the studied wood building is 22.5%, assuming that an earthquake occurs. The proposed method is therefore a useful and simple way to evaluate tsunami risk using a response-surface and Monte Carlo simulation without conducting multiple tsunami numerical simulations.
Evaluation of sampling methods for toxicological testing of indoor air particulate matter.
Tirkkonen, Jenni; Täubel, Martin; Hirvonen, Maija-Riitta; Leppänen, Hanna; Lindsley, William G; Chen, Bean T; Hyvärinen, Anne; Huttunen, Kati
2016-09-01
There is a need for toxicity tests capable of recognizing indoor environments with compromised air quality, especially in the context of moisture damage. One of the key issues is sampling, which should both provide meaningful material for analyses and fulfill requirements imposed by practitioners using toxicity tests for health risk assessment. We aimed to evaluate different existing methods of sampling indoor particulate matter (PM) to develop a suitable sampling strategy for a toxicological assay. During three sampling campaigns in moisture-damaged and non-damaged school buildings, we evaluated one passive and three active sampling methods: the Settled Dust Box (SDB), the Button Aerosol Sampler, the Harvard Impactor and the National Institute for Occupational Safety and Health (NIOSH) Bioaerosol Cyclone Sampler. Mouse RAW264.7 macrophages were exposed to particle suspensions and cell metabolic activity (CMA), production of nitric oxide (NO) and tumor necrosis factor (TNFα) were determined after 24 h of exposure. The repeatability of the toxicological analyses was very good for all tested sampler types. Variability within the schools was found to be high especially between different classrooms in the moisture-damaged school. Passively collected settled dust and PM collected actively with the NIOSH Sampler (Stage 1) caused a clear response in exposed cells. The results suggested the higher relative immunotoxicological activity of dust from the moisture-damaged school. The NIOSH Sampler is a promising candidate for the collection of size-fractionated PM to be used in toxicity testing. The applicability of such sampling strategy in grading moisture damage severity in buildings needs to be developed further in a larger cohort of buildings.
Implementation of Kriging Methods in Mobile GIS to Estimate Damage to Buildings in Crisis Scenarios
NASA Astrophysics Data System (ADS)
Laun, S.; Rösch, N.; Breunig, M.; Doori, M. Al
2016-06-01
In the paper an example for the application of kriging methods to estimate damage to buildings in crisis scenarios is introduced. Furthermore, the Java implementations for Ordinary and Universal Kriging on mobile GIS are presented. As variogram models an exponential, a Gaussian and a spherical variogram are tested in detail. Different test constellations are introduced with various information densities. As test data set, public data from the analysis of the 2010 Haiti earthquake by satellite images are pre-processed and visualized in a Geographic Information System. As buildings, topography and other external influences cannot be seen as being constant for the whole area under investigation, semi variograms are calculated by consulting neighboured classified buildings using the so called moving window method. The evaluation of the methods shows that the underlying variogram model is the determining factor for the quality of the interpolation rather than the choice of the kriging method or increasing the information density of a random sample. The implementation is completely realized with the programming language Java. Thereafter, the implemented software component is integrated into GeoTech Mobile, a mobile GIS Android application based on the processing of standardized spatial data representations defined by the Open Geospatial Consortium (OGC). As a result the implemented methods can be used on mobile devices, i.e. they may be transferred to other application fields. That is why we finally point out further research with new applications in the Dubai region.
NASA Astrophysics Data System (ADS)
Ghaffarian, Saman; Ghaffarian, Salar
2014-11-01
This paper proposes an improved FastICA model named as Purposive FastICA (PFICA) with initializing by a simple color space transformation and a novel masking approach to automatically detect buildings from high resolution Google Earth imagery. ICA and FastICA algorithms are defined as Blind Source Separation (BSS) techniques for unmixing source signals using the reference data sets. In order to overcome the limitations of the ICA and FastICA algorithms and make them purposeful, we developed a novel method involving three main steps: 1-Improving the FastICA algorithm using Moore-Penrose pseudo inverse matrix model, 2-Automated seeding of the PFICA algorithm based on LUV color space and proposed simple rules to split image into three regions; shadow + vegetation, baresoil + roads and buildings, respectively, 3-Masking out the final building detection results from PFICA outputs utilizing the K-means clustering algorithm with two number of clusters and conducting simple morphological operations to remove noises. Evaluation of the results illustrates that buildings detected from dense and suburban districts with divers characteristics and color combinations using our proposed method have 88.6% and 85.5% overall pixel-based and object-based precision performances, respectively.
Complex evaluation of the loft-style of retrivation as a type of building conversion
NASA Astrophysics Data System (ADS)
Chulkov, V.; Kazaryan, R.; Kuzina, O.; Maloyan, G.; Efimenko, A.
2017-10-01
Construction reorganization is part of a basic reorganization cycle in which four phases (phases, states, technological redistribution) are consistently implemented: device, disorganization, reorganization and co-organization. The field of our research lies in the phase of reconstruction. One of the varieties of building reconstruction is retrieval (from English retrieve - to restore, find) - bringing the reorganized object into a working state by attaching to the old functional building system of the new system. Retraining provides the ability to replace elements of the new system locally or in general (implementing the principle of “assembly-disassembly”) and provides for the elimination of the moral deterioration of the building and the normal operation of the facility. In the construction and transport industry there is a sufficiently large number of multiparameter tasks that require a systematic approach and the definition of a single integrated indicator of the effectiveness of the operation. These tasks can be solved using a variety of approaches. One of such approaches, as the method of integral evaluation based on stellar infographic models, is considered.
An Experimental Study of Energy Consumption in Buildings Providing Ancillary Services
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, Yashen; Afshari, Sina; Wolfe, John
Heating, ventilation, and air conditioning (HVAC) systems in commercial buildings can provide ancillary services (AS) to the power grid, but by providing AS their energy consumption may increase. This inefficiency is evaluated using round-trip efficiency (RTE), which is defined as the ratio between the decrease and the increase in the HVAC system's energy consumption compared to the baseline consumption as a result of providing AS. This paper evaluates the RTE of a 30,000 m2 commercial building providing AS. We propose two methods to estimate the HVAC system's settling time after an AS event based on temperature and the air flowmore » measurements from the building. Experimental data gathered over a 4-month period are used to calculate the RTE for AS signals of various waveforms, magnitudes, durations, and polarities. The results indicate that the settling time estimation algorithm based on the air flow measurements obtains more accurate results compared to the temperature-based algorithm. Further, we study the impact of the AS signal shape parameters on the RTE and discuss the practical implications of our findings.« less
Neural Networks for the Classification of Building Use from Street-View Imagery
NASA Astrophysics Data System (ADS)
Laupheimer, D.; Tutzauer, P.; Haala, N.; Spicker, M.
2018-05-01
Within this paper we propose an end-to-end approach for classifying terrestrial images of building facades into five different utility classes (commercial, hybrid, residential, specialUse, underConstruction) by using Convolutional Neural Networks (CNNs). For our examples we use images provided by Google Street View. These images are automatically linked to a coarse city model, including the outlines of the buildings as well as their respective use classes. By these means an extensive dataset is available for training and evaluation of our Deep Learning pipeline. The paper describes the implemented end-to-end approach for classifying street-level images of building facades and discusses our experiments with various CNNs. In addition to the classification results, so-called Class Activation Maps (CAMs) are evaluated. These maps give further insights into decisive facade parts that are learned as features during the training process. Furthermore, they can be used for the generation of abstract presentations which facilitate the comprehension of semantic image content. The abstract representations are a result of the stippling method, an importance-based image rendering.
What Is Design-Based Causal Inference for RCTs and Why Should I Use It? NCEE 2017-4025
ERIC Educational Resources Information Center
Schochet, Peter Z.
2017-01-01
Design-based methods have recently been developed as a way to analyze data from impact evaluations of interventions, programs, and policies. The impact estimators are derived using the building blocks of experimental designs with minimal assumptions, and have good statistical properties. The methods apply to randomized controlled trials (RCTs) and…
Appreciative Inquiry as a Method for Evaluation: An Interview with Hallie Preskill
ERIC Educational Resources Information Center
Christie, Christina A.
2006-01-01
This interview with Dr. Hallie Preskill focuses on the organizational change method known as appreciative inquiry (AI), which is described as a process that builds on past successes (and peak experiences) in an effort to design and implement future actions. Preskill takes the philosophy and principles put forth by organizational change AI…
Mota, Lia Toledo Moreira; Mota, Alexandre de Assis; Coiado, Lorenzo Campos
2015-01-01
Nowadays, buildings environmental certifications encourage the implementation of initiatives aiming to increase energy efficiency in buildings. In these certification systems, increased energy efficiency arising from such initiatives must be demonstrated. Thus, a challenge to be faced is how to check the increase in energy efficiency related to each of the employed initiatives without a considerable building retrofit. In this context, this work presents a non-destructive method for electric current sensing to assess implemented initiatives to increase energy efficiency in buildings with environmental certification. This method proposes the use of a sensor that can be installed directly in the low voltage electrical circuit conductors that are powering the initiative under evaluation, without the need for reforms that result in significant costs, repair, and maintenance. The proposed sensor consists of three elements: an air-core transformer current sensor, an amplifying/filtering stage, and a microprocessor. A prototype of the proposed sensor was developed and tests were performed to validate this sensor. Based on laboratory tests, it was possible to characterize the proposed current sensor with respect to the number of turns and cross-sectional area of the primary and secondary coils. Furthermore, using the Least Squares Method, it was possible to determine the efficiency of the air core transformer current sensor (the best efficiency found, considering different test conditions, was 2%), which leads to a linear output response. PMID:26184208
Mota, Lia Toledo Moreira; Mota, Alexandre de Assis; Coiado, Lorenzo Campos
2015-07-10
Nowadays, buildings environmental certifications encourage the implementation of initiatives aiming to increase energy efficiency in buildings. In these certification systems, increased energy efficiency arising from such initiatives must be demonstrated. Thus, a challenge to be faced is how to check the increase in energy efficiency related to each of the employed initiatives without a considerable building retrofit. In this context, this work presents a non-destructive method for electric current sensing to assess implemented initiatives to increase energy efficiency in buildings with environmental certification. This method proposes the use of a sensor that can be installed directly in the low voltage electrical circuit conductors that are powering the initiative under evaluation, without the need for reforms that result in significant costs, repair, and maintenance. The proposed sensor consists of three elements: an air-core transformer current sensor, an amplifying/filtering stage, and a microprocessor. A prototype of the proposed sensor was developed and tests were performed to validate this sensor. Based on laboratory tests, it was possible to characterize the proposed current sensor with respect to the number of turns and cross-sectional area of the primary and secondary coils. Furthermore, using the Least Squares Method, it was possible to determine the efficiency of the air core transformer current sensor (the best efficiency found, considering different test conditions, was 2%), which leads to a linear output response.
Assessment of Pansharpening Methods Applied to WorldView-2 Imagery Fusion.
Li, Hui; Jing, Linhai; Tang, Yunwei
2017-01-05
Since WorldView-2 (WV-2) images are widely used in various fields, there is a high demand for the use of high-quality pansharpened WV-2 images for different application purposes. With respect to the novelty of the WV-2 multispectral (MS) and panchromatic (PAN) bands, the performances of eight state-of-art pan-sharpening methods for WV-2 imagery including six datasets from three WV-2 scenes were assessed in this study using both quality indices and information indices, along with visual inspection. The normalized difference vegetation index, normalized difference water index, and morphological building index, which are widely used in applications related to land cover classification, the extraction of vegetation areas, buildings, and water bodies, were employed in this work to evaluate the performance of different pansharpening methods in terms of information presentation ability. The experimental results show that the Haze- and Ratio-based, adaptive Gram-Schmidt, Generalized Laplacian pyramids (GLP) methods using enhanced spectral distortion minimal model and enhanced context-based decision model methods are good choices for producing fused WV-2 images used for image interpretation and the extraction of urban buildings. The two GLP-based methods are better choices than the other methods, if the fused images will be used for applications related to vegetation and water-bodies.
Assessment of Pansharpening Methods Applied to WorldView-2 Imagery Fusion
Li, Hui; Jing, Linhai; Tang, Yunwei
2017-01-01
Since WorldView-2 (WV-2) images are widely used in various fields, there is a high demand for the use of high-quality pansharpened WV-2 images for different application purposes. With respect to the novelty of the WV-2 multispectral (MS) and panchromatic (PAN) bands, the performances of eight state-of-art pan-sharpening methods for WV-2 imagery including six datasets from three WV-2 scenes were assessed in this study using both quality indices and information indices, along with visual inspection. The normalized difference vegetation index, normalized difference water index, and morphological building index, which are widely used in applications related to land cover classification, the extraction of vegetation areas, buildings, and water bodies, were employed in this work to evaluate the performance of different pansharpening methods in terms of information presentation ability. The experimental results show that the Haze- and Ratio-based, adaptive Gram-Schmidt, Generalized Laplacian pyramids (GLP) methods using enhanced spectral distortion minimal model and enhanced context-based decision model methods are good choices for producing fused WV-2 images used for image interpretation and the extraction of urban buildings. The two GLP-based methods are better choices than the other methods, if the fused images will be used for applications related to vegetation and water-bodies. PMID:28067770
Li, Xiaolu; Liang, Yu
2015-05-20
Analysis of light detection and ranging (LiDAR) intensity data to extract surface features is of great interest in remote sensing research. One potential application of LiDAR intensity data is target classification. A new bidirectional reflectance distribution function (BRDF) model is derived for target characterization of rough and smooth surfaces. Based on the geometry of our coaxial full-waveform LiDAR system, the integration method is improved through coordinate transformation to establish the relationship between the BRDF model and intensity data of LiDAR. A series of experiments using typical urban building materials are implemented to validate the proposed BRDF model and integration method. The fitting results show that three parameters extracted from the proposed BRDF model can distinguish the urban building materials from perspectives of roughness, specular reflectance, and diffuse reflectance. A comprehensive analysis of these parameters will help characterize surface features in a physically rigorous manner.
NASA Astrophysics Data System (ADS)
Szafranko, Elżbieta
2017-10-01
Assessment of variant solutions developed for a building investment project needs to be made at the stage of planning. While considering alternative solutions, the investor defines various criteria, but a direct evaluation of the degree of their fulfilment by developed variant solutions can be very difficult. In practice, there are different methods which enable the user to include a large number of parameters into an analysis, but their implementation can be challenging. Some methods require advanced mathematical computations, preceded by complicating input data processing, and the generated results may not lend themselves easily to interpretation. Hence, during her research, the author has developed a systemic approach, which involves several methods and whose goal is to compare their outcome. The final stage of the proposed method consists of graphic interpretation of results. The method has been tested on a variety of building and development projects.
NASA Astrophysics Data System (ADS)
Toprak, A. Emre; Gülay, F. Gülten; Ruge, Peter
2008-07-01
Determination of seismic performance of existing buildings has become one of the key concepts in structural analysis topics after recent earthquakes (i.e. Izmit and Duzce Earthquakes in 1999, Kobe Earthquake in 1995 and Northridge Earthquake in 1994). Considering the need for precise assessment tools to determine seismic performance level, most of earthquake hazardous countries try to include performance based assessment in their seismic codes. Recently, Turkish Earthquake Code 2007 (TEC'07), which was put into effect in March 2007, also introduced linear and non-linear assessment procedures to be applied prior to building retrofitting. In this paper, a comparative study is performed on the code-based seismic assessment of RC buildings with linear static methods of analysis, selecting an existing RC building. The basic principles dealing the procedure of seismic performance evaluations for existing RC buildings according to Eurocode 8 and TEC'07 will be outlined and compared. Then the procedure is applied to a real case study building is selected which is exposed to 1998 Adana-Ceyhan Earthquake in Turkey, the seismic action of Ms = 6.3 with a maximum ground acceleration of 0.28 g It is a six-storey RC residential building with a total of 14.65 m height, composed of orthogonal frames, symmetrical in y direction and it does not have any significant structural irregularities. The rectangular shaped planar dimensions are 16.40 m×7.80 m = 127.90 m2 with five spans in x and two spans in y directions. It was reported that the building had been moderately damaged during the 1998 earthquake and retrofitting process was suggested by the authorities with adding shear-walls to the system. The computations show that the performing methods of analysis with linear approaches using either Eurocode 8 or TEC'07 independently produce similar performance levels of collapse for the critical storey of the structure. The computed base shear value according to Eurocode is much higher than the requirements of the Turkish Earthquake Code while the selected ground conditions represent the same characteristics. The main reason is that the ordinate of the horizontal elastic response spectrum for Eurocode 8 is increased by the soil factor. In TEC'07 force-based linear assessment, the seismic demands at cross-sections are to be checked with residual moment capacities; however, the chord rotations of primary ductile elements must be checked for Eurocode safety verifications. On the other hand, the demand curvatures from linear methods of analysis of Eurocode 8 together with TEC'07 are almost similar.
Evaluation of Sampling Methods for Bacillus Spore ...
Journal Article Following a wide area release of biological materials, mapping the extent of contamination is essential for orderly response and decontamination operations. HVAC filters process large volumes of air and therefore collect highly representative particulate samples in buildings. HVAC filter extraction may have great utility in rapidly estimating the extent of building contamination following a large-scale incident. However, until now, no studies have been conducted comparing the two most appropriate sampling approaches for HVAC filter materials: direct extraction and vacuum-based sampling.
ERIC Educational Resources Information Center
Coles, Emma; Watt, Celia; Freeman, Ruth
2013-01-01
Objective: To use a qualitative exploration to evaluate whether "Something to Smile About" (STSA), an oral health intervention, had increased the oral health capacity of staff working with homeless people. Setting: A National Health Service board area in Scotland. Method: A purposive sample of 14 staff members from STSA-participating…
ERIC Educational Resources Information Center
Peckham, Nicholas Guy; Howlett, Susan; Corbett, Alan
2007-01-01
Background: Sexual abuse has been associated with trauma, low self-esteem, anger, depression and challenging behaviours. This pilot study builds on a small published literature by evaluating a survivors group (SG) for women with an intellectual disability and an educational support group (ESG) for their carers. Method: The SG was delivered weekly…
Pre-Occupancy Evaluation of Patient Satisfaction in Hospitals.
van der Zwart, Johan; van der Voordt, Theo J M
2015-01-01
To explore analytical drawing techniques as a means to assess the attainment of preset objectives in the design phase of hospital buildings and to test ex ante if the building fits with these objectives, with a focus on view on nature, wayfinding, daylight, visibility of patient areas from reception desks, privacy, and communication between medical staff and patients, and noise reduction. The impact of the build environment on user value is at the core of evidence-based design, but these values are normally only experienced by users after the building is constructed. Therefore, assessment of these values during the design phase could improve the outcome for patients. An analysis of available assessment tools showed that research by drawing and the use of space syntax methods is an adequate means to visualize the strengths and weaknesses of floor plans in relation to spatial user experience. This approach is illustrated by an assessment of a nursing ward of the Deventer hospital in the Netherlands. Floor plan analysis by using space syntax techniques makes it possible to visualize various aspects of user value and supports the incorporation of usability issues in the discussion between the designer, the client, and the users during the design process. It is recommended to test the findings of the design assessment by a post-occupancy evaluation of the building-in-use and to conduct similar studies in other hospitals, as a means to build a body of knowledge for user-oriented design and management of hospital buildings. © The Author(s) 2015.
Martin, Caroline J Hollins; Robb, Yvonne; Forrest, Eleanor
2016-04-01
Equipping student midwives with confidence to deliver bereavement care to childbearing women is a challenge for midwifery lecturers. To explore qualitative data provided by student midwives who evaluated the workbook Bereavement care for childbearing women and their families (Hollins Martin & Forrest, 2013) to explore their views of potential teaching strategies that could build their confidence to deliver real bereavement care. An exploratory qualitative thematic analysis was used to provide, analyse and report themes identified within data collected in a prior study. Participants were student midwives (n=179) in their second/third year of a midwifery degree program at 1 of 3 universities in the UK were included in the study. Data to evaluate effectiveness of the bereavement workbook as a teaching method was collected using a survey instrument. It was the comments written under questions by participants that were analysed in the present study. Three themes emerged: (1) increasing classroom interaction, (2) the importance of reflecting on emotions, and (3) need for experience. Although this study has addressed delivery of education that relates to midwives, the findings are cross transferable to other healthcare educators, practitioners, and students. Several solutions are proposed that could potentially build student confidence to deliver bereavement care: lecturers should (1) encourage group discussion in the classroom to help build student confidence to emotionally cope during real bereavement events; (2) ensure students gain exposure by encouraging qualified midwives to include them in real bereavement events early on in their training, and (3) develop packages of perinatal bereavement scenarios for simulation and rehearsal in the clinical skills laboratory. Post-implementation, it is recommended that these teaching strategies be evaluated. Copyright © 2016 Elsevier Ltd. All rights reserved.
The Impact of School Building Conditions on Student Absenteeism in Upstate New York
Hwang, Syni-An; Fitzgerald, Edward F.; Kielb, Christine; Lin, Shao
2010-01-01
Objectives. We investigated Upstate New York school building conditions and examined the associations between school absenteeism and building condition problems. Methods. We merged data from the 2005 Building Condition Survey of Upstate New York schools with 2005 New York State Education Department student absenteeism data at the individual school level and evaluated associations between building conditions and absenteeism at or above the 90th percentile. Results. After adjustment for confounders, student absenteeism was associated with visible mold (odds ratio [OR] = 2.22; 95% confidence interval [CI] = 1.34, 3.68), humidity (OR = 3.07; 95% CI = 1.37, 6.89), poor ventilation (OR = 3.10; 95% CI = 1.79, 5.37), vermin (OR = 2.23; 95% CI = 1.32, 3.76), 6 or more individual building condition problems (OR = 2.97; 95% CI = 1.84, 4.79), and building system or structural problems related to these conditions. Schools in lower socioeconomic districts and schools attended by younger students showed the strongest associations between poor building conditions and absenteeism. Conclusions. We found associations between student absenteeism and adverse school building conditions. Future studies should confirm these findings and prioritize strategies for school condition improvements. PMID:20634471
Improving Building Energy Simulation Programs Through Diagnostic Testing (Fact Sheet)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2012-02-01
New test procedure evaluates quality and accuracy of energy analysis tools for the residential building retrofit market. Reducing the energy use of existing homes in the United States offers significant energy-saving opportunities, which can be identified through building simulation software tools that calculate optimal packages of efficiency measures. To improve the accuracy of energy analysis for residential buildings, the National Renewable Energy Laboratory's (NREL) Buildings Research team developed the Building Energy Simulation Test for Existing Homes (BESTEST-EX), a method for diagnosing and correcting errors in building energy audit software and calibration procedures. BESTEST-EX consists of building physics and utility billmore » calibration test cases, which software developers can use to compare their tools simulation findings to reference results generated with state-of-the-art simulation tools. Overall, the BESTEST-EX methodology: (1) Tests software predictions of retrofit energy savings in existing homes; (2) Ensures building physics calculations and utility bill calibration procedures perform to a minimum standard; and (3) Quantifies impacts of uncertainties in input audit data and occupant behavior. BESTEST-EX is helping software developers identify and correct bugs in their software, as well as develop and test utility bill calibration procedures.« less
Arul, P; Smitha, Shetty; Masilamani, Suresh; Akshatha, C
2018-01-01
Cytogenetic damage in exfoliated buccal epithelial cells due to environmental and occupational exposure is often monitored by micronucleus (MN) assay using liquid based cytology (LBC) preparations. This study was performed to evaluate MN in exfoliated buccal epithelial cells of building construction workers using LBC preparations. LBC preparations of exfoliated buccal epithelial cells from 100 subjects [50 building construction workers (cases) and 50 administrative staffs (controls)] was evaluated by May-Grunwald Giemsa, Hematoxylin and Eosin and Papanicolaou stains. Student's t test was used for statistical analysis and a P value of <0.05 was considered as statistically significant. The mean frequencies of MN for cases were significantly higher than controls regardless of staining methods used. There were statistically significant differences between smokers and non-smokers of the controls as well as duration of working exposure (<5 and >5 years) and smokers and non-smokers of cases (P=0.001). However, there were meaningful differences regarding mean frequencies of MN between smokers, non-smokers, those with alcohol consumption or not in cases and controls using various stains (P=0.001). There was an increased risk of cytogenetic damage in building construction workers. However, evaluation of MN of exfoliated buccal epithelial cells in building construction workers serve as a minimally invasive biomarker for cytogenetic damage. LBC preparations can be applied for MN assay as it improves the quality of smears and cell morphology, decreases the confounding factors and reduces false positive results.
Evaluating investment in quality improvement capacity building: a systematic review.
Mery, Gustavo; Dobrow, Mark J; Baker, G Ross; Im, Jennifer; Brown, Adalsteinn
2017-02-20
Leading health systems have invested in substantial quality improvement (QI) capacity building, but little is known about the aggregate effect of these investments at the health system level. We conducted a systematic review to identify key steps and elements that should be considered for system-level evaluations of investment in QI capacity building. We searched for evaluations of QI capacity building and evaluations of QI training programmes. We included the most relevant indexed databases in the field and a strategic search of the grey literature. The latter included direct electronic scanning of 85 relevant government and institutional websites internationally. Data were extracted regarding evaluation design and common assessment themes and components. 48 articles met the inclusion criteria. 46 articles described initiative-level non-economic evaluations of QI capacity building/training, while 2 studies included economic evaluations of QI capacity building/training, also at the initiative level. No system-level QI capacity building/training evaluations were found. We identified 17 evaluation components that fit within 5 overarching dimensions (characteristics of QI training; characteristics of QI activity; individual capacity; organisational capacity and impact) that should be considered in evaluations of QI capacity building. 8 key steps in return-on-investment (ROI) assessments in QI capacity building were identified: (1) planning-stakeholder perspective; (2) planning-temporal perspective; (3) identifying costs; (4) identifying benefits; (5) identifying intangible benefits that will not be included in the ROI estimation; (6) discerning attribution; (7) ROI calculations; (8) sensitivity analysis. The literature on QI capacity building evaluation is limited in the number and scope of studies. Our findings, summarised in a Framework to Guide Evaluations of QI Capacity Building , can be used to start closing this knowledge gap. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoon Lee, Sang; Hong, Tianzhen; Sawaya, Geof
The paper presents a method and process to establish a database of energy efficiency performance (DEEP) to enable quick and accurate assessment of energy retrofit of commercial buildings. DEEP was compiled from results of about 35 million EnergyPlus simulations. DEEP provides energy savings for screening and evaluation of retrofit measures targeting the small and medium-sized office and retail buildings in California. The prototype building models are developed for a comprehensive assessment of building energy performance based on DOE commercial reference buildings and the California DEER prototype buildings. The prototype buildings represent seven building types across six vintages of constructions andmore » 16 California climate zones. DEEP uses these prototypes to evaluate energy performance of about 100 energy conservation measures covering envelope, lighting, heating, ventilation, air-conditioning, plug-loads, and domestic hot water. DEEP consists the energy simulation results for individual retrofit measures as well as packages of measures to consider interactive effects between multiple measures. The large scale EnergyPlus simulations are being conducted on the super computers at the National Energy Research Scientific Computing Center of Lawrence Berkeley National Laboratory. The pre-simulation database is a part of an on-going project to develop a web-based retrofit toolkit for small and medium-sized commercial buildings in California, which provides real-time energy retrofit feedback by querying DEEP with recommended measures, estimated energy savings and financial payback period based on users’ decision criteria of maximizing energy savings, energy cost savings, carbon reduction, or payback of investment. The pre-simulated database and associated comprehensive measure analysis enhances the ability to performance assessments of retrofits to reduce energy use for small and medium buildings and business owners who typically do not have resources to conduct costly building energy audit. DEEP will be migrated into the DEnCity - DOE’s Energy City, which integrates large-scale energy data for multi-purpose, open, and dynamic database leveraging diverse source of existing simulation data.« less
DECONTAMINATION OF STRUCTURES AND DEBRIS AT SUPERFUND SITES
Two building decontamination technologies were demonstrated and evaluated: a method for in situ degradation of PCB's requiring application of an alkali metal/polyethylene glycolate mixture directly on concrete surfaces; and a shotblasting technique using steel shot to cut away co...
Comparison of different approaches of modelling in a masonry building
NASA Astrophysics Data System (ADS)
Saba, M.; Meloni, D.
2017-12-01
The present work has the objective to model a simple masonry building, through two different modelling methods in order to assess their validity in terms of evaluation of static stresses. Have been chosen two of the most commercial software used to address this kind of problem, which are of S.T.A. Data S.r.l. and Sismicad12 of Concrete S.r.l. While the 3Muri software adopts the Frame by Macro Elements Method (FME), which should be more schematic and more efficient, Sismicad12 software uses the Finite Element Method (FEM), which guarantees accurate results, with greater computational burden. Remarkably differences of the static stresses, for such a simple structure between the two approaches have been found, and an interesting comparison and analysis of the reasons is proposed.
NASA Astrophysics Data System (ADS)
Bartmański, Cezary; Bochenek, Wojciech; Passia, Henryk; Szade, Adam
2006-06-01
The methods of direct measurement and analysis of the dynamic response of a building structure through real-time recording of the amplitude of low-frequency vibration (tilt) have been presented. Subject to analyses was the reaction induced either by kinematic excitation (road traffic and mining-induced vibration) or controlled action of solid-fuel rocket micro-engines installed on the building. The forces were analysed by means of a set of transducers installed both in the ground and on the structure. After the action of excitation forces has been stopped, the system (structure) makes damped vibration around the static equilibrium position. It has been shown that the type of excitation affects the accuracy of evaluation of principal dynamic parameters of the structure. In the authors opinion these are the decrement of damping and natural vibration frequency. Positive results of tests with the use of excitation by means of short-action (0.6 second) rocket micro-engines give a chance to develop a reliable method for periodical assessment of acceptable loss of usability characteristics of building structures heavily influenced by environmental effects.
NASA Astrophysics Data System (ADS)
Sharaf, J. M.; Saleh, H.
2015-05-01
The shielding properties of three different construction styles, and building materials, commonly used in Jordan, were evaluated using parameters such as attenuation coefficients, equivalent atomic number, penetration depth and energy buildup factor. Geometric progression (GP) method was used to calculate gamma-ray energy buildup factors of limestone, concrete, bricks, cement plaster and air for the energy range 0.05-3 MeV, and penetration depths up to 40 mfp. It has been observed that among the examined building materials, limestone offers highest value for equivalent atomic number and linear attenuation coefficient and the lowest values for penetration depth and energy buildup factor. The obtained buildup factors were used as basic data to establish the total equivalent energy buildup factors for three different multilayer construction styles using an iterative method. The three styles were then compared in terms of fractional transmission of photons at different incident photon energies. It is concluded that, in case of any nuclear accident, large multistory buildings with five layers exterior walls, style A, could effectively attenuate radiation more than small dwellings of any construction style.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-14
... for OMB Review; Comment Request; YouthBuild Impact Evaluation, Youth Follow-Up Surveys ACTION: Notice...) sponsored information collection request (ICR) proposal titled, ``YouthBuild Impact Evaluation, Youth Follow... teaching them construction skills geared toward career placement. The YouthBuild Impact Evaluation will...
Fading test using the SAAD-POSL method for retrospective accidental dosimetry of building materials
NASA Astrophysics Data System (ADS)
Kim, M. J.; Lee, Y. J.; Lee, J. I.; Kim, J. L.; Hong, D. G.
2015-11-01
Fading test using the single aliquot additive dose method with pulsed optically stimulated luminescence (SAAD-POSL method) was applied to core-disc samples extracted from heated red brick, tile, roof-tile, and toilet porcelain after X-ray and beta irradiation. From thermoluminescence measurements of each material, the optimal preheat condition of the SAAD-POSL method was first determined as 170 °C for 10 s. Fading characteristics of core-disc samples of heated red brick obtained using the SAAD-POSL method were similar to those of quartz grains (90-250 μm) obtained using the SAR-OSL method, regardless of the differences in the sample and radiation type. Fading evaluations of the core-disc samples of these building materials two weeks after irradiation showed that the equivalent dose (ED) decreased between 5% and 42%. The results indicate that the fading characteristics will be able to contribute to a more accurate estimation of the ED value using the SAAD-POSL method.
The Effectiveness of Full Day School System for Students’ Character Building
NASA Astrophysics Data System (ADS)
Benawa, A.; Peter, R.; Makmun, S.
2018-01-01
The study aims to put forward that full day school which was delivered in Marsudirini Elementary School in Bogor is effective for students’ character building. The study focused on the implementation of full day school system. The qualitative-based research method applied in the study is characteristic evaluation involving non-participant observation, interview, and documentation analysis. The result of this study concludes that the full day school system is significantly effective in education system for elementary students’ character building. The full day school system embraced the entire relevant processes based on the character building standard. The synergy of comprehensive components in instructional process at full day school has influenced the building of the students’ character effectively and efficiently. The relationship emerged between instructional development process in full day school system and the character building of the students. By developing instructional process through systemic and systematic process in full day school system, the support of stakeholders (leaders, human resources, students, parents’ role) and other components (learning resources, facilities, budget) provides a potent and expeditious contribution for character building among the students eventually.
Assessment of energy and economic performance of office building models: a case study
NASA Astrophysics Data System (ADS)
Song, X. Y.; Ye, C. T.; Li, H. S.; Wang, X. L.; Ma, W. B.
2016-08-01
Energy consumption of building accounts for more than 37.3% of total energy consumption while the proportion of energy-saving buildings is just 5% in China. In this paper, in order to save potential energy, an office building in Southern China was selected as a test example for energy consumption characteristics. The base building model was developed by TRNSYS software and validated against the recorded data from the field work in six days out of August-September in 2013. Sensitivity analysis was conducted for energy performance of building envelope retrofitting; five envelope parameters were analyzed for assessing the thermal responses. Results indicated that the key sensitivity factors were obtained for the heat-transfer coefficient of exterior walls (U-wall), infiltration rate and shading coefficient (SC), of which the sum sensitivity factor was about 89.32%. In addition, the results were evaluated in terms of energy and economic analysis. The analysis of sensitivity validated against some important results of previous studies. On the other hand, the cost-effective method improved the efficiency of investment management in building energy.
Resilient design in the conservation of Johar market heritage building
NASA Astrophysics Data System (ADS)
Roesmanto, Totok
2017-12-01
Johar Market building based on Law of Repubic of Indonesia No.11 of 2010 is a heritage building. It was built in 1936 located near traditional square of Pasebaan and Aloon- Aloon was built by Dutch merchants union in 1678. Semarang based on decentralized policy by the Dutch Government in 1906 became a trading city. Rapid development of trading activities has caused the city planning policy by Semarang Government since 1970 made Aloon-Aloon become market buildings. Johar Market and market buildings in surrounding were on fire in 2015. Basing on Law No.11 of 2010 Semarang Government plans to conserve Johar Market heritage building and reconstruct Aloon-Aloon based on proposal of Roesmanto in 2016. The architect bureau assigned by the Semarang Government designed a new building in the middle of South-Johar Market to accommodate Johar merchants. This study aims to evaluate the design of new building by the architect bureau considering that since 2012 the city of Semarang including earthquake prone areas. The revitalization of Johar Market should use resilient design in order to prevent future damages to heritage buildings located nearby and new building must be spaced sufficiently against surrounding heritage buildings. This research uses descriptive qualitative method base on the field data after Johar Market burned and design planned bureau architect. The results of this study found that the distance between new building and heritage building is less wide.
Building a Personalized Cancer Treatment System.
Martinez, Alexandra; López, Gustavo; Bola Nos, Constantino; Alvarado, Daniel; Solano, Andrés; López, Mariana; Báez, Andrés; Quirós, Steve; Mora, Rodrigo
2017-02-01
This paper reports the process by which a personalized cancer treatment system was built, following a user-centered approach. We give some background on personalized cancer treatment, the particular tumor chemosensitivity assay supported by the system, as well as some quality and legal issues related to such health systems. We describe how Contextual Design was applied when building the system. Contextual design is a user-centered design technique involving seven steps. We also provide some details about the system implementation. Finally, we explain how the Think-Aloud protocol and Heuristic Evaluation methods were used to evaluate the system and report its results. A qualitative assessment from the users perspective is also provided. Results from the heuristic evaluation indicate that only one of ten heuristics was missing from the system, while five were partially covered and four were fully covered.
Hsu, David
2015-09-27
Clustering methods are often used to model energy consumption for two reasons. First, clustering is often used to process data and to improve the predictive accuracy of subsequent energy models. Second, stable clusters that are reproducible with respect to non-essential changes can be used to group, target, and interpret observed subjects. However, it is well known that clustering methods are highly sensitive to the choice of algorithms and variables. This can lead to misleading assessments of predictive accuracy and mis-interpretation of clusters in policymaking. This paper therefore introduces two methods to the modeling of energy consumption in buildings: clusterwise regression,more » also known as latent class regression, which integrates clustering and regression simultaneously; and cluster validation methods to measure stability. Using a large dataset of multifamily buildings in New York City, clusterwise regression is compared to common two-stage algorithms that use K-means and model-based clustering with linear regression. Predictive accuracy is evaluated using 20-fold cross validation, and the stability of the perturbed clusters is measured using the Jaccard coefficient. These results show that there seems to be an inherent tradeoff between prediction accuracy and cluster stability. This paper concludes by discussing which clustering methods may be appropriate for different analytical purposes.« less
Study of an experimental methodology for thermal properties diagnostic of building envelop
NASA Astrophysics Data System (ADS)
Yang, Yingying; Sempy, Alain; Vogt Wu, Tingting; Sommier, Alain; Dumoulin, Jean; Batsale, Jean Christophe
2017-04-01
The building envelope plays a critical role in determining levels of comfort and building efficiency. Its real thermal properties characterization is of major interest to be able to diagnose energy efficiency performance of buildings (new construction and retrofitted existing old building). Research and development on a possible methodology for energy diagnostic of the building envelop is a hot topic and necessary trend. Many kinds of sensors and instruments are used for the studies. The application of infrared (IR) thermography in non-destructive evaluation has been widely employed for qualitative evaluations for building diagnostics; meanwhile, the IR thermography technology also has a large potentiality for the evaluation of the thermal characteristics of the building envelope. Some promising recent research studies have been carried out with such contactless measurement technique. Nevertheless, research efforts are still required for in situ measurements under natural environmental conditions. In order to develop new solutions for non-intrusive evaluation of local thermal performance, enabling quantitative assessment of thermal properties of buildings and materials, experiments were carried out on a multi-layer pratical scale wall fixed on a caisson placed in a climatic chamber. Six halogen lamps (1.5 kW for each lamp) placed in front of objective wall were used to emulate sunny conditions. The radiative heat flux emitted was monitored and modulated with time according to typical weather data set encountered in France. Both steady state and transient regime heat transfer were studied during these experiments. Contact sensors (thermocouples, heat flux meters, Peltier sensors) and non-contact sensors (thermal IR camera, pyranometer) were used to measure the temperatures and heat flux density evolution. It has to be noticed that the Peltier sensors have been tuned and used with a specific processing to set them compliant for heat flux density measurements. The measured data from different sensors were analysed and compared. The emissivity of wall surface and treated sensor surfaces were evaluated by using an IR camera with an adapted post-processing. Then, convective and radiative heat fluxes, at wall level, were estimated. Finally, the wall thermal properties can be calculated by using the measured temperatures and estimated heat fluxes using a dedicated thermal quadrupoles heat transfer model and an inverse method. This study aims at providing some guidelines for the choice of sensors, measurements protocol and adapted inverse model to be tested in real conditions on pilot situ scale. Aknowledgments : The Authors are very grateful to H2020 Built2Spec project for supporting this work.
Tuned apatitic materials: Synthesis, characterization and potential antimicrobial applications
NASA Astrophysics Data System (ADS)
Fierascu, Irina; Fierascu, Radu Claudiu; Somoghi, Raluca; Ion, Rodica Mariana; Moanta, Adriana; Avramescu, Sorin Marius; Damian, Celina Maria; Ditu, Lia Mara
2018-04-01
Inorganic antimicrobial materials can be viable for multiple applications (related to its use for new buildings with special requirements related to microbiological loading, such as hospital buildings and for consolidation of cultural heritage constructions); also the use of substituted hydroxyapatites for protection of stone artefacts against environmental factors (acidic rain) and biodeterioration it's an option to no longer use of toxic substances. This paper presents methods of synthesis and characterization of the material from the point of view of the obtained structures and final applications. The materials were characterized in terms of composition and morphology (using X-ray Diffraction, X-ray Fluorescence, Inductively coupled plasma-atomic emission spectrometry, Fourier Transform Infrared Spectroscopy, X-ray Photoelectron Spectroscopy, Surface area and pore size determination). Antimicrobial activity was tested against filamentous fungi strains and pathogenic bacteria strains, using both spot on lawn qualitative method (on agar medium) and serial microdilution quantitative method (in broth medium). Further, it was evaluated the anti-biofilm activity of the tested samples toward the most important microbial strains implicated in biofilm development, using crystal violet stained biofilms microtiter assay, followed by spectrophotometric quantitative evaluation.
Nondestructive structural evaluation of wood floor systems with a vibration technique.
Xiping Wang; Robert J. Ross; Lawrence Andrew Soltis
2002-01-01
The objective of this study was to determine if transverse vibration methods could be used to effectively assess the structural integrity of wood floors as component systems. A total of 10 wood floor systems, including 3 laboratory-built floor sections and 7 in-place floors in historic buildings, were tested. A forced vibration method was applied to the floor systems...
76 FR 74076 - Notice of Random Assignment Study To Evaluate the YouthBuild Program; Final Notice
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-30
... Evaluate the YouthBuild Program; Final Notice AGENCY: Employment and Training Administration (ETA), Labor... rigorous, nationally-representative estimates of the net impacts of the YouthBuild program. The Department... study. In the sites randomly selected to participate in this evaluation, all applicants for YouthBuild...
Building capacity for Health Impact Assessment: Training outcomes from the United States
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schuchter, Joseph; Rutt, Candace, E-mail: awr8@cdc.gov; Satariano, William A.
2015-01-15
Background: Despite the continued growth of Health Impact Assessment (HIA) in the US, there is little research on HIA capacity-building. A comprehensive study of longer-term training outcomes may reveal opportunities for improving capacity building activities and HIA practice. Methods: We conducted in-depth interviews with HIA trainees in the United States to assess their outcomes and needs. Using a training evaluation framework, we measured outcomes across a spectrum of reaction, learning, behavior and results. Results: From 2006 to 2012, four organizations trained over 2200 people in at least 75 in-person HIA trainings in 29 states. We interviewed 48 trainees, selected bothmore » randomly and purposefully. The mean duration between training and interview was 3.4 years. Trainees reported that their training objectives were met, especially when relevant case-studies were used. They established new collaborations at the trainings and maintained them. Training appeared to catalyze more holistic thinking and practice, including a range of HIA-related activities. Many trainees disseminated what they learned and engaged in components of HIA, even without dedicated funding. Going forward, trainees need assistance with quantitative methods, project management, community engagement, framing recommendations, and evaluation. Conclusions: The research revealed opportunities for a range of HIA stakeholders to refine and coordinate training resources, apply a competency framework and leverage complimentary workforce development efforts, and sensitize and build the capacity of communities. - Highlights: • We interviewed HIA trainees in the United States to assess longer-term outcomes. • Training appeared to catalyze a range of beneficial partnerships and activities. • Trainees reported outstanding needs for specific skills and competencies. • There are various opportunities to improve training and capacity-building.« less
Code of Federal Regulations, 2014 CFR
2014-07-01
... regulated areas. Building/facility owner is the legal entity, including a lessee, which exercises control... education, training, and experience to anticipate, recognize, evaluate and develop controls for occupational... appendix A to this section, or by an equivalent method. (2) Excursion limit. The employer shall ensure that...
Code of Federal Regulations, 2012 CFR
2012-07-01
... regulated areas. Building/facility owner is the legal entity, including a lessee, which exercises control... education, training, and experience to anticipate, recognize, evaluate and develop controls for occupational... appendix A to this section, or by an equivalent method. (2) Excursion limit. The employer shall ensure that...
BULK SAMPLE ANALYSIS FOR ASBESTOS CONTENT: EVALUATION OF THE TENTATIVE METHOD
The U.S. Environmental Protection Agency Asbestos-in-Schools Program was established in March, 1979 to provide information and technical assistance to the public for addressing problems presented by asbestos-containing insulation materials in school buildings. Because there were ...
Evaluating the compatibility of multi-functional and intensive urban land uses
NASA Astrophysics Data System (ADS)
Taleai, M.; Sharifi, A.; Sliuzas, R.; Mesgari, M.
2007-12-01
This research is aimed at developing a model for assessing land use compatibility in densely built-up urban areas. In this process, a new model was developed through the combination of a suite of existing methods and tools: geographical information system, Delphi methods and spatial decision support tools: namely multi-criteria evaluation analysis, analytical hierarchy process and ordered weighted average method. The developed model has the potential to calculate land use compatibility in both horizontal and vertical directions. Furthermore, the compatibility between the use of each floor in a building and its neighboring land uses can be evaluated. The method was tested in a built-up urban area located in Tehran, the capital city of Iran. The results show that the model is robust in clarifying different levels of physical compatibility between neighboring land uses. This paper describes the various steps and processes of developing the proposed land use compatibility evaluation model (CEM).
NASA Astrophysics Data System (ADS)
Collier, Richard S.; McKenna, Paul M.; Perala, Rodney A.
1991-08-01
The objective here is to describe the lightning hazards to buildings and their internal environments using advanced formulations of Maxwell's Equations. The method described is the Three Dimensional Finite Difference Time Domain Solution. It can be used to solve for the lightning interaction with such structures in three dimensions with the inclusion of a considerable amount of detail. Special techniques were developed for including wire, plumbing, and rebar into the model. Some buildings have provisions for lightning protection in the form of air terminals connected to a ground counterpoise system. It is shown that fields and currents within these structures can be significantly high during a lightning strike. Time lapse video presentations were made showing the electric and magnetic field distributions on selected cross sections of the buildings during a simulated lightning strike.
NASA Technical Reports Server (NTRS)
Collier, Richard S.; Mckenna, Paul M.; Perala, Rodney A.
1991-01-01
The objective here is to describe the lightning hazards to buildings and their internal environments using advanced formulations of Maxwell's Equations. The method described is the Three Dimensional Finite Difference Time Domain Solution. It can be used to solve for the lightning interaction with such structures in three dimensions with the inclusion of a considerable amount of detail. Special techniques were developed for including wire, plumbing, and rebar into the model. Some buildings have provisions for lightning protection in the form of air terminals connected to a ground counterpoise system. It is shown that fields and currents within these structures can be significantly high during a lightning strike. Time lapse video presentations were made showing the electric and magnetic field distributions on selected cross sections of the buildings during a simulated lightning strike.
Use of Automated External Defibrillators in US Federal Buildings
Kilaru, Austin S.; Leffer, Marc; Perkner, John; Sawyer, Kate Flanigan; Jolley, Chandra E.; Nadkarni, Lindsay D.; Shofer, Frances S.; Merchant, Raina M.
2014-01-01
Objective Federal Occupational Health (FOH) administers a nationwide public access defibrillation program in US federal buildings. We describe the use of automated external defibrillators (AEDs) in federal buildings and evaluate survival after cardiac arrest. Methods Using the FOH database, we examined reported events in which an AED was brought to a medical emergency in federal buildings over a 14-year period, from 1999 to 2012. Results There were 132 events involving an AED, 96 (73%) of which were due to cardiac arrest of cardiac etiology. Of 54 people who were witnessed to experience a cardiac arrest and presented with ventricular fibrillation or ventricular tachycardia, 21 (39%) survived to hospital discharge. Conclusions Public access defibrillation, along with protocols to install, maintain, and deploy AEDs and train first responders, benefits survival after cardiac arrest in the workplace. PMID:24351893
Airborne sound transmission loss characteristics of wood-frame construction
NASA Astrophysics Data System (ADS)
Rudder, F. F., Jr.
1985-03-01
This report summarizes the available data on the airborne sound transmission loss properties of wood-frame construction and evaluates the methods for predicting the airborne sound transmission loss. The first part of the report comprises a summary of sound transmission loss data for wood-frame interior walls and floor-ceiling construction. Data bases describing the sound transmission loss characteristics of other building components, such as windows and doors, are discussed. The second part of the report presents the prediction of the sound transmission loss of wood-frame construction. Appropriate calculation methods are described both for single-panel and for double-panel construction with sound absorption material in the cavity. With available methods, single-panel construction and double-panel construction with the panels connected by studs may be adequately characterized. Technical appendices are included that summarize laboratory measurements, compare measurement with theory, describe details of the prediction methods, and present sound transmission loss data for common building materials.
2013-01-01
Background There are repeated calls to build better cycling paths in Australian cities if the proportion of people cycling is to increase. Yet the full range of transport, health, environmental and economic impacts of new cycling infrastructure and the extent to which observed changes are sustained is not well understood. The City of Sydney is currently building a new bicycle network, which includes a new bicycle path separated from road traffic in the south Sydney area. This protocol paper describes a comprehensive method to evaluate this new cycling infrastructure. Method A cohort of residents within two kilometres of the new bicycle path will be surveyed at baseline before a new section of bicycle path is built, and again 12 and 24 months later to assess changes in travel behaviour, sense of community, quality of life and health behaviours. Residents in a comparable area of Sydney that will not get a new separated bike path will act as a comparison group. At baseline a sub-set of residents who volunteer will also take a small GPS device with them for one week to assess travel behaviour. Discussion This research should contribute to the advancement in evaluation and appraisal methods for cycling projects. PMID:24131667
Assessment of Seismic Damage on The Exist Buildings Using Fuzzy Logic
NASA Astrophysics Data System (ADS)
Pınar, USTA; Nihat, MOROVA; EVCİ, Ahmet; ERGÜN, Serap
2018-01-01
Earthquake as a natural disaster could damage the lives of many people and buildings all over the world. These is micvulnerability of the buildings needs to be evaluated. Accurate evaluation of damage sustained by buildings during natural disaster events is critical to determine the buildings safety and their suitability for future occupancy. The earthquake is one of the disasters that structures face the most. There fore, there is a need to evaluate seismic damage and vulnerability of the buildings to protect them. These days fuzzy systems have been widely used in different fields of science because of its simpli city and efficiency. Fuzzy logic provides a suitable framework for reasoning, deduction, and decision making in fuzzy conditions. In this paper, studies on earthquake hazard evaluation of buildings by fuzzy logic modeling concepts in the literature have been investigated and evaluated, as a whole.
Establishing a Common Definition for Zero Energy Buildings: Time to Move the Market
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peterson, Kent; Torcellini, Paul; Taylor, Cody
To change the current paradigm from buildings being consumers of energy to producers of energy requires a common language to facilitate market transformation. Common definitions help create market movement by sharing concepts across market actors. While the term 'zero energy buildings' has been in the marketplace for over 20 years, no common definition had been established. US DOE, last year, embarked on a process to evaluate current definitions and solicit industry input to formulate a common definition and nomenclature for zero energy buildings. This definition uses commonly available site measurements and national conversion factors to define zero energy buildings onmore » a source energy basis for a variety of boundary conditions including building, portfolio, campus, and community. Issues addressed include multiple fuel types, cogeneration, and renewable energy certificates. This paper describes the process used to arrive at the definition, looks at methods of calculating site to source energy conversions, and how boundary decisions affect a robust and stable definition that can be used to direct programs and policies for many years to come. This stability is critical to move building investments towards buildings that produce as much energy as they consume.« less
Building Change Detection in Very High Resolution Satellite Stereo Image Time Series
NASA Astrophysics Data System (ADS)
Tian, J.; Qin, R.; Cerra, D.; Reinartz, P.
2016-06-01
There is an increasing demand for robust methods on urban sprawl monitoring. The steadily increasing number of high resolution and multi-view sensors allows producing datasets with high temporal and spatial resolution; however, less effort has been dedicated to employ very high resolution (VHR) satellite image time series (SITS) to monitor the changes in buildings with higher accuracy. In addition, these VHR data are often acquired from different sensors. The objective of this research is to propose a robust time-series data analysis method for VHR stereo imagery. Firstly, the spatial-temporal information of the stereo imagery and the Digital Surface Models (DSMs) generated from them are combined, and building probability maps (BPM) are calculated for all acquisition dates. In the second step, an object-based change analysis is performed based on the derivative features of the BPM sets. The change consistence between object-level and pixel-level are checked to remove any outlier pixels. Results are assessed on six pairs of VHR satellite images acquired within a time span of 7 years. The evaluation results have proved the efficiency of the proposed method.
Monitoring of Dermanyssus gallinae in free-range poultry farms.
Zenner, L; Bon, G; Chauve, C; Nemoz, C; Lubac, S
2009-06-01
Various methods for monitoring Dermanyssus gallinae infestations within free-range egg production units were compared. The study was carried out in five egg-producing free-range poultry buildings infested with D. gallinae. Each farm was divided into six zones (each zone including nest boxes, perches and duckboard) for placing two types of traps (corrugated cardboard and thick card traps) or examining dried droppings for presence of mites. Traps were removed 24 h later, placed into bags and mites were counted at the laboratory using binocular magnification. Droppings were also inspected by eye and mite numbers were estimated. All the methods used allowed us to detect mites although their efficacy differed. The number of mites collected was independent of the type of trap used. Examination of the droppings did not differentiate between buildings with differing mite populations. Placing traps in the nest boxes is a less reliable indicator than placing them on the perches. It appears that the most coherent method for evaluating the D. gallinae population within a free-range flock is to place thick card traps throughout the building, on perches favoured by birds.
Building a community-based culture of evaluation.
Janzen, Rich; Ochocka, Joanna; Turner, Leanne; Cook, Tabitha; Franklin, Michelle; Deichert, Debbie
2017-12-01
In this article we argue for a community-based approach as a means of promoting a culture of evaluation. We do this by linking two bodies of knowledge - the 70-year theoretical tradition of community-based research and the trans-discipline of program evaluation - that are seldom intersected within the evaluation capacity building literature. We use the three hallmarks of a community-based research approach (community-determined; equitable participation; action and change) as a conceptual lens to reflect on a case example of an evaluation capacity building program led by the Ontario Brian Institute. This program involved two community-based groups (Epilepsy Southwestern Ontarioand the South West Alzheimer Society Alliance) who were supported by evaluators from the Centre for Community Based Research to conduct their own internal evaluation. The article provides an overview of a community-based research approach and its link to evaluation. It then describes the featured evaluation capacity building initiative, including reflections by the participating organizations themselves. We end by discussing lessons learned and their implications for future evaluation capacity building. Our main argument is that organizations that strive towards a community-based approach to evaluation are well placed to build and sustain a culture of evaluation. Copyright © 2017 Elsevier Ltd. All rights reserved.
Cost savings threshold analysis of a capacity-building program for HIV prevention organizations.
Dauner, Kim Nichols; Oglesby, Willie H; Richter, Donna L; LaRose, Christopher M; Holtgrave, David R
2008-06-01
Although the incidence of HIV each year remains steady, prevention funding is increasingly competitive. Programs need to justify costs in terms of evaluation outcomes, including economic ones. Threshold analyses set performance standards to determine program effectiveness relative to that threshold. This method was used to evaluate the potential cost savings of a national capacity-building program for HIV prevention organizations. Program costs were compared with the lifetime treatment costs of HIV, yielding an estimate of the HIV infections that would have to be prevented for the program to be cost saving. The 136 persons who completed the capacity-building program between 2000 and 2003 would have to avert 41 cases of HIV for the program to be considered cost saving. These figures represent less than one tenth of 1% of the 40,000 new HIV infections that occur in the United States annually and suggest a reasonable performance standard. These data underscore the resources needed to prevent HIV.
Global optimization framework for solar building design
NASA Astrophysics Data System (ADS)
Silva, N.; Alves, N.; Pascoal-Faria, P.
2017-07-01
The generative modeling paradigm is a shift from static models to flexible models. It describes a modeling process using functions, methods and operators. The result is an algorithmic description of the construction process. Each evaluation of such an algorithm creates a model instance, which depends on its input parameters (width, height, volume, roof angle, orientation, location). These values are normally chosen according to aesthetic aspects and style. In this study, the model's parameters are automatically generated according to an objective function. A generative model can be optimized according to its parameters, in this way, the best solution for a constrained problem is determined. Besides the establishment of an overall framework design, this work consists on the identification of different building shapes and their main parameters, the creation of an algorithmic description for these main shapes and the formulation of the objective function, respecting a building's energy consumption (solar energy, heating and insulation). Additionally, the conception of an optimization pipeline, combining an energy calculation tool with a geometric scripting engine is presented. The methods developed leads to an automated and optimized 3D shape generation for the projected building (based on the desired conditions and according to specific constrains). The approach proposed will help in the construction of real buildings that account for less energy consumption and for a more sustainable world.
a New Quantitative Method for the Rapid Evaluation of Buildings against Earthquakes
NASA Astrophysics Data System (ADS)
Mahmoodzadeh, Amir; Mazaheri, Mohammad Mehdi
2008-07-01
At the present time there exist numerous weak buildings which are not able to withstand earthquakes. At the same time, both private and public developers are trying to use scientific methods to prioritize and allocate budget in order to reinforce the above mentioned structures. This is because of the limited financial resources and time. In the recent years the procedure of seismic assessment before rehabilitation of vulnerable buildings has been implemented in many countries. Now, it seems logical to reinforce the existing procedures with the mass of available data about the effects caused by earthquakes on buildings. The main idea is driven from FMEA (Failure Mode and Effect Analysis) in quality management where the main procedure is to recognize the failure, the causes, and the priority of each cause and failure. Specifying the causes and effects which lead to a certain shortcoming in structural behavior during earthquakes, an inventory is developed and each building is rated through a yes-or-no procedure. In this way, the rating of the structure is based on some standard forms which along with relative weights are developed in this study. The resulted criteria by rapid assessment will indicate whether the structure is to be demolished, has a high, medium or low vulnerability or is invulnerable.
Muller, George; Perkins, Casey J.; Lancaster, Mary J.; MacDonald, Douglas G.; Clements, Samuel L.; Hutton, William J.; Patrick, Scott W.; Key, Bradley Robert
2015-07-28
Computer-implemented security evaluation methods, security evaluation systems, and articles of manufacture are described. According to one aspect, a computer-implemented security evaluation method includes accessing information regarding a physical architecture and a cyber architecture of a facility, building a model of the facility comprising a plurality of physical areas of the physical architecture, a plurality of cyber areas of the cyber architecture, and a plurality of pathways between the physical areas and the cyber areas, identifying a target within the facility, executing the model a plurality of times to simulate a plurality of attacks against the target by an adversary traversing at least one of the areas in the physical domain and at least one of the areas in the cyber domain, and using results of the executing, providing information regarding a security risk of the facility with respect to the target.
Building Assessment Survey and Evaluation Study Summarized Data - HVAC Characteristics
In the Building Assessment Survey and Evaluation (BASE) Study Information on the characteristics of the heating, ventilation, and air conditioning (HVAC) system(s) in the entire BASE building including types of ventilation, equipment configurations, and operation and maintenance issues was acquired by examining the building plans, conducting a building walk-through, and speaking with the building owner, manager, and/or operator.
Zhao, H; Stephens, B
2016-08-01
Recent experiments have demonstrated that outdoor ozone reacts with materials inside residential building enclosures, potentially reducing indoor exposures to ozone or altering ozone reaction byproducts. However, test methods to measure ozone penetration factors in residences (P) remain limited. We developed a method to measure ozone penetration factors in residences under infiltration conditions and applied it in an unoccupied apartment unit. Twenty-four repeated measurements were made, and results were explored to (i) evaluate the accuracy and repeatability of the new procedure using multiple solution methods, (ii) compare results from 'interference-free' and conventional UV absorbance ozone monitors, and (iii) compare results against those from a previously published test method requiring artificial depressurization. The mean (±s.d.) estimate of P was 0.54 ± 0.10 across a wide range of conditions using the new method with an interference-free monitor; the conventional monitor was unable to yield meaningful results due to relatively high limits of detection. Estimates of P were not clearly influenced by any indoor or outdoor environmental conditions or changes in indoor decay rate constants. This work represents the first known measurements of ozone penetration factors in a residential building operating under natural infiltration conditions and provides a new method for widespread application in buildings. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
A Web-based Alternative Non-animal Method Database for Safety Cosmetic Evaluations
Kim, Seung Won; Kim, Bae-Hwan
2016-01-01
Animal testing was used traditionally in the cosmetics industry to confirm product safety, but has begun to be banned; alternative methods to replace animal experiments are either in development, or are being validated, worldwide. Research data related to test substances are critical for developing novel alternative tests. Moreover, safety information on cosmetic materials has neither been collected in a database nor shared among researchers. Therefore, it is imperative to build and share a database of safety information on toxicological mechanisms and pathways collected through in vivo, in vitro, and in silico methods. We developed the CAMSEC database (named after the research team; the Consortium of Alternative Methods for Safety Evaluation of Cosmetics) to fulfill this purpose. On the same website, our aim is to provide updates on current alternative research methods in Korea. The database will not be used directly to conduct safety evaluations, but researchers or regulatory individuals can use it to facilitate their work in formulating safety evaluations for cosmetic materials. We hope this database will help establish new alternative research methods to conduct efficient safety evaluations of cosmetic materials. PMID:27437094
A Web-based Alternative Non-animal Method Database for Safety Cosmetic Evaluations.
Kim, Seung Won; Kim, Bae-Hwan
2016-07-01
Animal testing was used traditionally in the cosmetics industry to confirm product safety, but has begun to be banned; alternative methods to replace animal experiments are either in development, or are being validated, worldwide. Research data related to test substances are critical for developing novel alternative tests. Moreover, safety information on cosmetic materials has neither been collected in a database nor shared among researchers. Therefore, it is imperative to build and share a database of safety information on toxicological mechanisms and pathways collected through in vivo, in vitro, and in silico methods. We developed the CAMSEC database (named after the research team; the Consortium of Alternative Methods for Safety Evaluation of Cosmetics) to fulfill this purpose. On the same website, our aim is to provide updates on current alternative research methods in Korea. The database will not be used directly to conduct safety evaluations, but researchers or regulatory individuals can use it to facilitate their work in formulating safety evaluations for cosmetic materials. We hope this database will help establish new alternative research methods to conduct efficient safety evaluations of cosmetic materials.
Start Your Engines...Start Your Year!
ERIC Educational Resources Information Center
Adair, Lila M.; Loveless, Garry C.
1994-01-01
Provides a first-week activity in which student groups brainstorm and build cars to win a race. Includes rules, suggestions, time line, and evaluation methods. Notes that many misconceptions may arise from the activity but these are dealt with in the next few weeks of class. (MVL)
Progress on Evaluating School Buildings in Scotland
ERIC Educational Resources Information Center
Thomson, Keith
2006-01-01
In June 2004, the Scottish Executive published guidance on evaluating completed school building projects, "Building Our Future: Scotland's School Estate," as part of the School Estate Strategy; the guidance included a case study evaluation at an Edinburgh primary school. The Executive is continuing to support evaluation work on the school estate…
Hulse, Thomas E.; Adamkiewicz, Gary; Levy, Douglas E.; Bethune, Leon; Kane, John; Reid, Margaret; Shah, Snehal N.
2015-01-01
Introduction. Secondhand smoke remains a health concern for individuals living in multiunit housing, where smoke has been shown to easily transfer between units. Building-wide smoke-free policies are a logical step for minimizing smoke exposure in these settings. This evaluation sought to determine whether buildings with smoke-free policies have less secondhand smoke than similar buildings without such policies. Furthermore, this study assessed potential secondhand smoke transfer between apartments with and without resident smokers. Methods. Fine particulate matter (PM2.5), airborne nicotine, and self-reported smoking activity were recorded in 15 households with resident smokers and 17 households where no one smoked in 5 Boston Housing Authority developments. Of these, 4 apartment pairs were adjacent apartments with and without resident smokers. Halls between apartments and outdoor air were also monitored to capture potential smoke transfer and to provide background PM2.5 concentrations. Results. Households within buildings with smoke-free policies showed lower PM2.5 concentrations compared to buildings without these policies (median: 4.8 vs 8.1 µg/m3). Although the greatest difference in PM2.5 between smoking-permitted and smoke-free buildings was observed in households with resident smokers (14.3 vs 7.0 µg/m3), households without resident smokers also showed a significant difference (5.1 vs 4.0 µg/m3). Secondhand smoke transfer to smoke-free apartments was demonstrable with directly adjacent households. Conclusion. This evaluation documented instances of secondhand smoke transfer between households as well as lower PM2.5 measurements in buildings with smoke-free policies. Building-wide smoke-free policies can limit secondhand smoke exposure for everyone living in multiunit housing. PMID:25156526
Test and evaluation procedures for Sandia's Teraflops Operating System (TOS) on Janus.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barnette, Daniel Wayne
This report describes the test and evaluation methods by which the Teraflops Operating System, or TOS, that resides on Sandia's massively-parallel computer Janus is verified for production release. Also discussed are methods used to build TOS before testing and evaluating, miscellaneous utility scripts, a sample test plan, and a proposed post-test method for quickly examining the large number of test results. The purpose of the report is threefold: (1) to provide a guide to T&E procedures, (2) to aid and guide others who will run T&E procedures on the new ASCI Red Storm machine, and (3) to document some ofmore » the history of evaluation and testing of TOS. This report is not intended to serve as an exhaustive manual for testers to conduct T&E procedures.« less
Ronald Billings; L. Allen Smith; Jin Zhu; Shailu Verma; Nick Kouchoukos; Joon Heo
2010-01-01
The objective of this research project is to develop and validate a method for using satellite images and digital geospatial data to map the distribution of southern pine beetle (SPB) habitats across the pinelands of east Texas. Our approach builds on a work that used photo interpretation and discriminant analysis to identify and evaluate environmental conditions...
Object-Based Dense Matching Method for Maintaining Structure Characteristics of Linear Buildings
Yan, Yiming; Qiu, Mingjie; Zhao, Chunhui; Wang, Liguo
2018-01-01
In this paper, we proposed a novel object-based dense matching method specially for the high-precision disparity map of building objects in urban areas, which can maintain accurate object structure characteristics. The proposed framework mainly includes three stages. Firstly, an improved edge line extraction method is proposed for the edge segments to fit closely to building outlines. Secondly, a fusion method is proposed for the outlines under the constraint of straight lines, which can maintain the building structural attribute with parallel or vertical edges, which is very useful for the dense matching method. Finally, we proposed an edge constraint and outline compensation (ECAOC) dense matching method to maintain building object structural characteristics in the disparity map. In the proposed method, the improved edge lines are used to optimize matching search scope and matching template window, and the high-precision building outlines are used to compensate the shape feature of building objects. Our method can greatly increase the matching accuracy of building objects in urban areas, especially at building edges. For the outline extraction experiments, our fusion method verifies the superiority and robustness on panchromatic images of different satellites and different resolutions. For the dense matching experiments, our ECOAC method shows great advantages for matching accuracy of building objects in urban areas compared with three other methods. PMID:29596393
Belgiu, Mariana; Dr Guţ, Lucian
2014-10-01
Although multiresolution segmentation (MRS) is a powerful technique for dealing with very high resolution imagery, some of the image objects that it generates do not match the geometries of the target objects, which reduces the classification accuracy. MRS can, however, be guided to produce results that approach the desired object geometry using either supervised or unsupervised approaches. Although some studies have suggested that a supervised approach is preferable, there has been no comparative evaluation of these two approaches. Therefore, in this study, we have compared supervised and unsupervised approaches to MRS. One supervised and two unsupervised segmentation methods were tested on three areas using QuickBird and WorldView-2 satellite imagery. The results were assessed using both segmentation evaluation methods and an accuracy assessment of the resulting building classifications. Thus, differences in the geometries of the image objects and in the potential to achieve satisfactory thematic accuracies were evaluated. The two approaches yielded remarkably similar classification results, with overall accuracies ranging from 82% to 86%. The performance of one of the unsupervised methods was unexpectedly similar to that of the supervised method; they identified almost identical scale parameters as being optimal for segmenting buildings, resulting in very similar geometries for the resulting image objects. The second unsupervised method produced very different image objects from the supervised method, but their classification accuracies were still very similar. The latter result was unexpected because, contrary to previously published findings, it suggests a high degree of independence between the segmentation results and classification accuracy. The results of this study have two important implications. The first is that object-based image analysis can be automated without sacrificing classification accuracy, and the second is that the previously accepted idea that classification is dependent on segmentation is challenged by our unexpected results, casting doubt on the value of pursuing 'optimal segmentation'. Our results rather suggest that as long as under-segmentation remains at acceptable levels, imperfections in segmentation can be ruled out, so that a high level of classification accuracy can still be achieved.
IEA EBC Annex 66: Definition and simulation of occupant behavior in buildings
Yan, Da; Hong, Tianzhen; Dong, Bing; ...
2017-09-28
Here, more than 30% of the total primary energy in the world is consumed in buildings. It is crucial to reduce building energy consumption in order to preserve energy resources and mitigate global climate change. Building performance simulations have been widely used for the estimation and optimization of building performance, providing reference values for the assessment of building energy consumption and the effects of energy-saving technologies. Among the various factors influencing building energy consumption, occupant behavior has drawn increasing attention. Occupant behavior includes occupant presence, movement, and interaction with building energy devices and systems. However, there are gaps in occupantmore » behavior modeling as different energy modelers have employed varied data and tools to simulate occupant behavior, therefore producing different and incomparable results. Aiming to address these gaps, the International Energy Agency (IEA) Energy in Buildings and Community (EBC) Programme Annex 66 has established a scientific methodological framework for occupant behavior research, including data collection, behavior model representation, modeling and evaluation approaches, and the integration of behavior modeling tools with building performance simulation programs. Annex 66 also includes case studies and application guidelines to assist in building design, operation, and policymaking, using interdisciplinary approaches to reduce energy use in buildings and improve occupant comfort and productivity. This paper highlights the key research issues, methods, and outcomes pertaining to Annex 66, and offers perspectives on future research needs to integrate occupant behavior with the building life cycle.« less
IEA EBC Annex 66: Definition and simulation of occupant behavior in buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yan, Da; Hong, Tianzhen; Dong, Bing
Here, more than 30% of the total primary energy in the world is consumed in buildings. It is crucial to reduce building energy consumption in order to preserve energy resources and mitigate global climate change. Building performance simulations have been widely used for the estimation and optimization of building performance, providing reference values for the assessment of building energy consumption and the effects of energy-saving technologies. Among the various factors influencing building energy consumption, occupant behavior has drawn increasing attention. Occupant behavior includes occupant presence, movement, and interaction with building energy devices and systems. However, there are gaps in occupantmore » behavior modeling as different energy modelers have employed varied data and tools to simulate occupant behavior, therefore producing different and incomparable results. Aiming to address these gaps, the International Energy Agency (IEA) Energy in Buildings and Community (EBC) Programme Annex 66 has established a scientific methodological framework for occupant behavior research, including data collection, behavior model representation, modeling and evaluation approaches, and the integration of behavior modeling tools with building performance simulation programs. Annex 66 also includes case studies and application guidelines to assist in building design, operation, and policymaking, using interdisciplinary approaches to reduce energy use in buildings and improve occupant comfort and productivity. This paper highlights the key research issues, methods, and outcomes pertaining to Annex 66, and offers perspectives on future research needs to integrate occupant behavior with the building life cycle.« less
Infography use to requirements specification for the design of the building
NASA Astrophysics Data System (ADS)
Losev, Konstantin; Sinenko, Sergey
2017-10-01
The study contributes to a growing body of research Transport infrastructure in a construction object life cycle management and presents areas in which further investigation is needed. The object of study are Railway buildings and structures and the Employer’s information requirements (EIR) for design of individual residential building. The task of the study was to determine necessary and sufficient scope of parameters which contained in inforaphic form of EIR comparing with traditional text form of EIR. Also, the task was to determine what categories of the traditional EIR are transferred to an infographic representation form and what categories are ignored in case of a relatively low complexity building. Methods that have been used in the study were infographical representation of text and further expert evaluation. Conclusions of the study present the necessary and sufficient scope of parameters for inforaphic form of EIR, the relations between infographic parameters and categories of the EIR traditional form and subcategories of the traditional EIR that are ignored in case of a relatively low complexity building.
Wang, Haibo; Chen, Hanjie; Cai, Ming
2018-08-01
The primary objective of this study was to develop an evaluation method for assessing an urban traffic noise-exposed population and apply it in the main urban area of Guangzhou. The method based on points of interest (POIs) and noise map is realized in several steps. First, after regionalizing based on road networks and executing a cluster analysis for regions according to the properties of POIs, the environmental noise functional regions (NFRs) of the urban area are presented. Then, surrounding POIs are used to infer the type of buildings, and according to the attraction of different building types and the whole population of the region, the population distribution at the building level is calculated. Finally, with the help of a noise map, an evaluation method for assessing an urban traffic noise-exposed population is proposed. The method is applied in the main urban area of Guangzhou, and the results reveal the followings. 1) At daytime and nighttime, 23.63% and 30.53% of the population, respectively, experience noise levels that exceed the noise standards. The per capita noise exposure value at daytime and nighttime is 0.9 dB and 2.0 dB, respectively. 2) The percentages of the exposed population of Yuexiu District were 28.89% at daytime and 35.65% at nighttime, which are the largest, followed by the exposed population percentages of Liwan, Haizhu, and Tianhe Districts. 3) From the view of different classes of NFRs, the percentages of the exposed population of Class 1 and Class 4 are larger than the percentages of the exposed population from the other classes, especially at nighttime (48.24% of Class 1 and 40.79% of Class 4). 4) Although there are masses of people affected by traffic noise, a large percentage of them (85%) experience not more than 5 dB of traffic noise superscale. Copyright © 2018 Elsevier Ltd. All rights reserved.
Medina, L; Acosta-Pérez, E; Velez, C; Martínez, G; Rivera, M; Sardiñas, L; Pattatucci, A
2015-10-01
This article describes the use of Success Case Method (Brinkerhoff, 2003) to evaluate health promotion and public health training programs. The goal of the Office Community Research and Engagement (OCRE) of the Puerto Rico Clinical and Translational Research Consortium (PRCTRC) is to establish a stable and sustainable translational research capacity. Early efforts toward achieving this goal included sponsoring two independent research training programs. A description of the implementation of the five step Success Case Method is presented. Results reveal that SCM would deem both trainings as highly successful, based upon the overall impact of a low number of success cases. However, a traditional summative evaluation would consider this disappointing. Strengths of SCM are discussed. It was concluded that the Success Case Method is a useful and valuable evaluative method for measuring the success of health promotion and public health training initiatives and provides sufficient information for decision-making processes. Copyright © 2015 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Toprak, A. Emre; Guelay, F. Guelten; Ruge, Peter
2008-07-08
Determination of seismic performance of existing buildings has become one of the key concepts in structural analysis topics after recent earthquakes (i.e. Izmit and Duzce Earthquakes in 1999, Kobe Earthquake in 1995 and Northridge Earthquake in 1994). Considering the need for precise assessment tools to determine seismic performance level, most of earthquake hazardous countries try to include performance based assessment in their seismic codes. Recently, Turkish Earthquake Code 2007 (TEC'07), which was put into effect in March 2007, also introduced linear and non-linear assessment procedures to be applied prior to building retrofitting. In this paper, a comparative study is performedmore » on the code-based seismic assessment of RC buildings with linear static methods of analysis, selecting an existing RC building. The basic principles dealing the procedure of seismic performance evaluations for existing RC buildings according to Eurocode 8 and TEC'07 will be outlined and compared. Then the procedure is applied to a real case study building is selected which is exposed to 1998 Adana-Ceyhan Earthquake in Turkey, the seismic action of Ms = 6.3 with a maximum ground acceleration of 0.28 g It is a six-storey RC residential building with a total of 14.65 m height, composed of orthogonal frames, symmetrical in y direction and it does not have any significant structural irregularities. The rectangular shaped planar dimensions are 16.40 mx7.80 m = 127.90 m{sup 2} with five spans in x and two spans in y directions. It was reported that the building had been moderately damaged during the 1998 earthquake and retrofitting process was suggested by the authorities with adding shear-walls to the system. The computations show that the performing methods of analysis with linear approaches using either Eurocode 8 or TEC'07 independently produce similar performance levels of collapse for the critical storey of the structure. The computed base shear value according to Eurocode is much higher than the requirements of the Turkish Earthquake Code while the selected ground conditions represent the same characteristics. The main reason is that the ordinate of the horizontal elastic response spectrum for Eurocode 8 is increased by the soil factor. In TEC'07 force-based linear assessment, the seismic demands at cross-sections are to be checked with residual moment capacities; however, the chord rotations of primary ductile elements must be checked for Eurocode safety verifications. On the other hand, the demand curvatures from linear methods of analysis of Eurocode 8 together with TEC'07 are almost similar.« less
A model for evaluating the environmental benefits of elementary school facilities.
Ji, Changyoon; Hong, Taehoon; Jeong, Kwangbok; Leigh, Seung-Bok
2014-01-01
In this study, a model that is capable of evaluating the environmental benefits of a new elementary school facility was developed. The model is composed of three steps: (i) retrieval of elementary school facilities having similar characteristics as the new elementary school facility using case-based reasoning; (ii) creation of energy consumption and material data for the benchmark elementary school facility using the retrieved similar elementary school facilities; and (iii) evaluation of the environmental benefits of the new elementary school facility by assessing and comparing the environmental impact of the new and created benchmark elementary school facility using life cycle assessment. The developed model can present the environmental benefits of a new elementary school facility in terms of monetary values using Environmental Priority Strategy 2000, a damage-oriented life cycle impact assessment method. The developed model can be used for the following: (i) as criteria for a green-building rating system; (ii) as criteria for setting the support plan and size, such as the government's incentives for promoting green-building projects; and (iii) as criteria for determining the feasibility of green building projects in key business sectors. Copyright © 2013 Elsevier Ltd. All rights reserved.
Optimization of design parameters of low-energy buildings
NASA Astrophysics Data System (ADS)
Vala, Jiří; Jarošová, Petra
2017-07-01
Evaluation of temperature development and related consumption of energy required for heating, air-conditioning, etc. in low-energy buildings requires the proper physical analysis, covering heat conduction, convection and radiation, including beam and diffusive components of solar radiation, on all building parts and interfaces. The system approach and the Fourier multiplicative decomposition together with the finite element technique offers the possibility of inexpensive and robust numerical and computational analysis of corresponding direct problems, as well as of the optimization ones with several design variables, using the Nelder-Mead simplex method. The practical example demonstrates the correlation between such numerical simulations and the time series of measurements of energy consumption on a small family house in Ostrov u Macochy (35 km northern from Brno).
NASA Astrophysics Data System (ADS)
Bijnagte, J. L.; Luger, D.
2012-12-01
In the Northern parts of the Netherlands exploration of natural gas reservoirs causes subsidence over large areas. As a consequence, the water levels in canals and polders have to be adjusted over time in order to keep the groundwater levels at a constant depth relative to the surface level. In the middle of the subsidence area it is relatively easy to follow the settlements by a uniform lowering of the water level. This would however result in a relative lowering of the groundwater table at the edges of the subsidence area. Given the presence of soft compressible soils, this would result in induced settlements. For buildings in these areas this will increase the chance of damage. A major design challenge lies therefore in the optimisation of the use of compartments. The more compartments the higher the cost therefore the aim is to make compartments in the water management system that are as large as possible without causing inadmissible damage to buildings. In order to asses expected damage from different use of compartments three tools are needed. The first is a generally accepted method of damage determination, the second a method to determine the contribution to damage of a new influence, e.g. a groundwater table change. Third, and perhaps most importantly, a method is needed to evaluate effects not for single buildings but for larger areas. The first need is covered by established damage criteria like those of Burland & Wroth or Boscardin & Cording. Up until now the second and the third have been problematic. This paper presents a method which enables to assign a contribution to the probability of damage of various recognised mechanisms such as soil and foundation inhomogeneity, uneven loading, ground water level changes. Shallow subsidence due to peat oxidation and deep subsidence due to reservoir depletion can be combined. In order to address the third issue: evaluation of effects for larger areas, the method uses a probabilistic approach. Apart from a description of the method itself validation of the approach is described by applying the theory to an area in the North of The Netherlands, near a canal, where a water level change was considered. This area consists of soft soil overlying sandy deposits. It was found that the damage percentages as given by the theory are in the right order of magnitude when compared to the actual damage observed in this area. For study of a large area affected by subsidence, input parameters have been established based on a field inspection of the state of the buildings present in that area. Groundwater changes resulting from water level adaptations have been calculated based on measurements of the present situation for ten cross sections. Results of the analyses show that lowering of the water table by 0.1-0.15 m influences a relatively small zone next to the canal only. Use of the new damage assesment method shows that even within this influenced zone, which is mostly less than 10 m wide, effects on buildings are rather limited. Almost in all cases the increase of chance of building damage is negligible.
NASA Astrophysics Data System (ADS)
Shimoda, Atsushi; Kosugi, Hidenori; Karino, Takafumi; Komoda, Norihisa
This study focuses on a stock reduction method for build-to-order (BTO) products to flow surplus parts out to the market using sale by recommendation. A sale by recommendation is repeated in an each business negotiation using a recommended configuration selected from the inventory of parts to minimize the stock deficiency or excess at the end of a certain period of the production plan. The method is based on the potential of a customer specification to be replaced by an alternative one if the alternative one is close to the initial customer specification. A recommendation method is proposed that decides the recommended product configuration by balancing the part consumption so that the alternative specification of the configuration is close enough to the initial customer specification for substitutability. The method was evaluated by a simulation using real BTO manufacturing data and the result demonstrates that the unbalance of the consumption of parts inventory is improved.
Studying the Elusive Experience in Pervasive Games
ERIC Educational Resources Information Center
Stenros, Jaakko; Waern, Annika; Montola, Markus
2012-01-01
Studying pervasive games is inherently difficult and different from studying computer or board games. This article builds upon the experiences of staging and studying several playful pervasive technology prototypes. It discusses the challenges and pitfalls of evaluating pervasive game prototypes and charts methods that have proven useful in…
Disassembly Properties of Cementitious Finish Joints Using an Induction Heating Method
Ahn, Jaecheol; Noguchi, Takafumi; Kitagaki, Ryoma
2015-01-01
Efficient maintenance and upgrading of a building during its lifecycle are difficult because a cementitious finish uses materials and parts with low disassembly properties. Additionally, the reuse and recycling processes during building demolition also present numerous problems from the perspective of environmental technology. In this study, an induction heating (IH) method was used to disassemble cementitious finish joints, which are widely used to join building members and materials. The IH rapidly and selectively heated and weakened these joints. The temperature elevation characteristics of the cementitious joint materials were measured as a function of several resistor types, including wire meshes and punching metals, which are usually used for cementitious finishing. The disassembly properties were evaluated through various tests using conductive resistors in cementitious joints such as mortar. When steel fiber, punching metal, and wire mesh were used as conductive resistors, the cementitious modifiers could be weakened within 30 s. Cementitious joints with conductive resistors also showed complete disassembly with little residual bond strength.
Metal leaching in drinking water domestic distribution system: an Italian case study.
Sorlini, Sabrina; Gialdini, Francesca; Collivignarelli, Carlo
2014-01-01
The objective of this study was to evaluate metal contamination of tap water in seven public buildings in Brescia (Italy). Two monitoring periods were performed using three different sampling methods (overnight stagnation, 30-min stagnation, and random daytime). The results show that the water parameters exceeding the international standards (Directive 98/83/EC) at the tap were lead (max = 363 μg/L), nickel (max = 184 μg/L), zinc (max = 4900 μg/L), and iron (max = 393 μg/L). Compared to the total number of tap water samples analyzed (122), the values higher than limits of Directive 98/83/EC were 17% for lead, 11% for nickel, 14% for zinc, and 7% for iron. Three buildings exceeded iron standard while five buildings exceeded the standard for nickel, lead, and zinc. Moreover, there is no evident correlation between the leaching of contaminants in the domestic distribution system and the age of the pipes while a significant influence is shown by the sampling methods.
Sawani, Shefali; Arora, Vipin; Jaiswal, Shikha; Nikhil, Vineeta
2014-01-01
Background: Evaluation of microleakage is important for assessing the success of new restorative materials and methods. Aim and Objectives: Comparative evaluation of microleakage in Class II restorations using open vs. closed centripetal build-up techniques with different lining materials. Materials and Methods: Standardized mesi-occlusal (MO) and distoocclusal (DO) Class II tooth preparations were preparedon 53 molars and samples were randomly divided into six experimental groups and one control group for restorations. Group 1: Open-Sandwich technique (OST) with flowable composite at the gingival seat. Group 2: OST with resin-modified glass ionomer cement (RMGIC) at the gingival seat. Group 3: Closed-Sandwich technique (CST) with flowable composite at the pulpal floor and axial wall. Group 4: CST with RMGIC at the pulpal floor and axial wall. Group 5: OST with flowable composite at the pulpal floor, axial wall, and gingival seat. Group 6: OST with RMGIC at the pulpal floor, axial wall, and gingival seat. Group 7: Control — no lining material, centripetal technique only. After restorations and thermocycling, apices were sealed and samples were immersed in 0.5% basic fuchsin dye. Sectioning was followed by stereomicroscopic evaluation. Results: Results were analyzed using Post Hoc Bonferroni test (statistics is not a form of tabulation). Cervical scores of control were more than the exprimental groups (P < 0.05). Less microleakage was observed in CST than OST in all experimental groups (P < 0.05). However, insignificant differences were observed among occlusal scores of different groups (P > 0.05). Conclusion: Class II composite restorations with centripetal build-up alone or when placed with CST reduces the cervical microleakage when compared to OST. PMID:25125847
NASA Astrophysics Data System (ADS)
Formisano, Antonio; Chiumiento, Giovanni; Fabbrocino, Francesco; Landolfo, Raffaele
2017-07-01
The general objective of the work is to draw attention to the issue of seismic vulnerability analysis of masonry building compounds, which characterise most of the Italian historic towns. The study is based on the analysis of an aggregated construction falling in the town of Arsita (Teramo, Italy) damaged after the 2009 L'Aquila earthquake. A comparison between the seismic verifications carried out by using the 3Muri commercial software and those deriving from the application of the Italian Guidelines on Cultural Heritage has been performed. The comparison has shown that Guidelines provide results on the safe side in predicting the seismic behaviour of the building compound under study. Further analyses should be performed aiming at suggesting some modifications of the used simplified calculation method to better interpret the behaviour of building compounds under earthquake.
Limited energy study, Buildings 750 and 798, Fort Richardson, Alaska. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-02-01
The purpose of this study is to identify and evaluate Energy Conservation Opportunities (ECOs) for two motor pool facilities, Buildings 750 and 798, to determine their energy savings potential, economic feasibility, and to document results for possible future funding. Buildings 750 and 798 are heated by steam supplied from a central plant. The central plant uses natural gas as a primary fuel source to produce steam for both heating and electrical energy generation. Since power is produced on the base there is not a demand charge for electrical energy. Two ECOs examined the use of natural gas in conjunction withmore » steam as a method of heating the buildings. Annual baseline energy consumption and cost data for each building is presented. The heating system in Building 750 was found to be severely under capacity. This is the result of the disabling of the under-floor heating system and the roof top MAUs. Building 798 also has had the under-floor heating system disabled. However, baseline simulations show that the remaining system is capable of maintaining thermostat setpoints during all but the coldest days of a typical year.« less
A Fast Evaluation Method for Energy Building Consumption Based on the Design of Experiments
NASA Astrophysics Data System (ADS)
Belahya, Hocine; Boubekri, Abdelghani; Kriker, Abdelouahed
2017-08-01
Building sector is one of the effective consumer energy by 42% in Algeria. The need for energy has continued to grow, in inordinate way, due to lack of legislation on energy performance in this large consumer sector. Another reason is the simultaneous change of users’ requirements to maintain their comfort, especially summer in dry lands and parts of southern Algeria, where the town of Ouargla presents a typical example which leads to a large amount of electricity consumption through the use of air conditioning. In order to achieve a high performance envelope of the building, an optimization of major parameters building envelope is required, using design of experiments (DOE), can determine the most effective parameters and eliminate the less importance. The study building is often complex and time consuming due to the large number of parameters to consider. This study focuses on reducing the computing time and determines the major parameters of building energy consumption, such as area of building, factor shape, orientation, ration walls to windows …etc to make some proposal models in order to minimize the seasonal energy consumption due to air conditioning needs.
Tsai, Yu Hsin; Stow, Douglas; Weeks, John
2013-01-01
The goal of this study was to map and quantify the number of newly constructed buildings in Accra, Ghana between 2002 and 2010 based on high spatial resolution satellite image data. Two semi-automated feature detection approaches for detecting and mapping newly constructed buildings based on QuickBird very high spatial resolution satellite imagery were analyzed: (1) post-classification comparison; and (2) bi-temporal layerstack classification. Feature Analyst software based on a spatial contextual classifier and ENVI Feature Extraction that uses a true object-based image analysis approach of image segmentation and segment classification were evaluated. Final map products representing new building objects were compared and assessed for accuracy using two object-based accuracy measures, completeness and correctness. The bi-temporal layerstack method generated more accurate results compared to the post-classification comparison method due to less confusion with background objects. The spectral/spatial contextual approach (Feature Analyst) outperformed the true object-based feature delineation approach (ENVI Feature Extraction) due to its ability to more reliably delineate individual buildings of various sizes. Semi-automated, object-based detection followed by manual editing appears to be a reliable and efficient approach for detecting and enumerating new building objects. A bivariate regression analysis was performed using neighborhood-level estimates of new building density regressed on a census-derived measure of socio-economic status, yielding an inverse relationship with R2 = 0.31 (n = 27; p = 0.00). The primary utility of the new building delineation results is to support spatial analyses of land cover and land use and demographic change. PMID:24415810
Multicriteria decision model for retrofitting existing buildings
NASA Astrophysics Data System (ADS)
Bostenaru Dan, B.
2003-04-01
In this paper a model to decide which buildings from an urban area should be retrofitted is presented. The model has been cast into existing ones by choosing the decision rule, criterion weighting and decision support system types most suitable for the spatial problem of reducing earthquake risk in urban areas, considering existing spatial multiatributive and multiobjective decision methods and especially collaborative issues. Due to the participative character of the group decision problem "retrofitting existing buildings" the decision making model is based on interactivity. Buildings have been modeled following the criteria of spatial decision support systems. This includes identifying the corresponding spatial elements of buildings according to the information needs of actors from different sphaeres like architects, construction engineers and economists. The decision model aims to facilitate collaboration between this actors. The way of setting priorities interactivelly will be shown, by detailing the two phases: judgemental and computational, in this case site analysis, collection and evaluation of the unmodified data and converting survey data to information with computational methods using additional expert support. Buildings have been divided into spatial elements which are characteristic for the survey, present typical damages in case of an earthquake and are decisive for a better seismic behaviour in case of retrofitting. The paper describes the architectural and engineering characteristics as well as the structural damage for constuctions of different building ages on the example of building types in Bucharest, Romania in compressible and interdependent charts, based on field observation, reports from the 1977 earthquake and detailed studies made by the author together with a local engineer for the EERI Web Housing Encyclopedia. On this base criteria for setting priorities flow into the expert information contained in the system.
The impact evaluation of soil liquefaction on low-rise building in the Meinong earthquake
NASA Astrophysics Data System (ADS)
Lu, Chih-Chieh; Hwang, Jin-Hung; Hsu, Shang-Yi
2017-08-01
This paper presents major preliminary observations on the liquefaction-induced damages in the Meinong earthquake ( M L = 6.4). The severe damages to buildings centered on Huian and Sanmin Streets in Tainan City where the places were reclaimed fish or farm ponds with poor construction quality from many decades ago. To better understand the effect due to the soil liquefaction at these sites, the information provided by the in situ 13 Standard Penetration Test boreholes and 5 Cone Penetration Test soundings accompanying with the PGAs derived from the near seismographs was used to conduct the soil liquefaction evaluation by the Seed method (Seed et al. in J Geotech Eng ASCE 111(12):1425-1445, 1985) when subject to the Meinong earthquake. The liquefaction potential index (LPI) was then evaluated accordingly. From the results, it was found that the estimated damage severity was not consistent to the field conditions if the local site effect was not taken into account. To better reflect the site response in such sites, the sites' PGAs in the PGA contour map were multiplied by 1.5 times to quantify the amplification effects due to the soft geological condition. In addition, the PGAs based on other simple approaches were evaluated as well for comparison. Besides, the effects of fines content and magnitude scaling factor were also discussed in this paper. After that, several common simplified methods were also used to calculate the LPI when subject to the Meinong earthquake in order to evaluate the applicability of these simplified methods.
Multi-Sensor Radiometric Study to Detect Pathologies in Historical Buildings
NASA Astrophysics Data System (ADS)
Del Pozo, S.; Herrero-Pascual, J.; Felipe-García, B.; Hernández-López, D.; Rodríguez-Gonzálvez, P.; González-Aguilera, D.
2015-02-01
This paper presents a comparative study with different remote sensing technologies to recognize pathologies in façades of historical buildings. Building materials deteriorate over the years due to different extrinsic and intrinsic agents, so assessing these diseases in a non-invasive way is crucial to help preserve them. Most of these buildings are extremely valuable and some of them have been declared monuments of cultural interest. In this way through close range remote sensing techniques, it is possible to study material pathologies in a rigorous way and in a short duration field campaign. For the investigation two different acquisition systems were applied, active and passive methods. The terrestrial laser scanner FARO Focus 3D was used as active sensor, working at the wavelength of 905 nm. For the case of passive sensors, a Nikon D-5000 and a 6- bands Mini-MCA multispectral camera (530-801 nm) were applied covering visible and near infrared spectral range. This analysis allows assessing the sensor, or sensors combination, suitability for pathologies detection, addressing the limitations according to the spatial and spectral resolution. Moreover, the pathology detection by unsupervised classification methods is addressed in order to evaluate the automation capability of this process.
10 CFR 434.505 - Reference building method.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505...
10 CFR 434.505 - Reference building method.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505.1...
10 CFR 434.505 - Reference building method.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505...
10 CFR 434.505 - Reference building method.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505...
10 CFR 434.505 - Reference building method.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505...
A new evaluation tool to obtain practice-based evidence of worksite health promotion programs.
Dunet, Diane O; Sparling, Phillip B; Hersey, James; Williams-Piehota, Pamela; Hill, Mary D; Hanssen, Carl; Lawrenz, Frances; Reyes, Michele
2008-10-01
The Centers for Disease Control and Prevention developed the Swift Worksite Assessment and Translation (SWAT) evaluation method to identify promising practices in worksite health promotion programs. The new method complements research studies and evaluation studies of evidence-based practices that promote healthy weight in working adults. We used nationally recognized program evaluation standards of utility, feasibility, accuracy, and propriety as the foundation for our 5-step method: 1) site identification and selection, 2) site visit, 3) post-visit evaluation of promising practices, 4) evaluation capacity building, and 5) translation and dissemination. An independent, outside evaluation team conducted process and summative evaluations of SWAT to determine its efficacy in providing accurate, useful information and its compliance with evaluation standards. The SWAT evaluation approach is feasible in small and medium-sized workplace settings. The independent evaluation team judged SWAT favorably as an evaluation method, noting among its strengths its systematic and detailed procedures and service orientation. Experts in worksite health promotion evaluation concluded that the data obtained by using this evaluation method were sufficient to allow them to make judgments about promising practices. SWAT is a useful, business-friendly approach to systematic, yet rapid, evaluation that comports with program evaluation standards. The method provides a new tool to obtain practice-based evidence of worksite health promotion programs that help prevent obesity and, more broadly, may advance public health goals for chronic disease prevention and health promotion.
Morphometrical study on senile larynx.
Zieliński, R
2001-01-01
The aim of the study was a morphometrical macroscopic evaluation of senile larynges, according to its usefulness in ORL diagnostic and operational methods. Larynx preparations were taken from cadavers of both sexes, of age 65 and over, about 24 hours after death. Clinically important laryngeal diameters were collected using common morphometrical methods. A few body features were also being gathered. Computer statistical methods were used in data assessment, including basic statistics and linear correlations between diameters and between diameters and body features. The data presented in the study may be very helpful in evaluation of diagnostic methods. It may also help in selection of right operational tool' sizes, the most appropriate operational technique choice, preoperative preparations and designing and building virtual and plastic models for physicians' training.
The Life Cycle Evaluation Model of External Diseconomy of Open-loop Supply Chain
NASA Astrophysics Data System (ADS)
Liu, Qian; Hu, Tianjun
2017-08-01
In recent years, with the continuous deterioration of pollution, resource space is gradually narrowed, the number of waste items increased, people began to use the method of recycling on waste products to ease the pressure on the environment. This paper adopted the external diseconomy of open-loop supply chain as the research object and constructed the model by the life cycle evaluation method, comparative analysis through the case. This paper also concludes that the key to solving the problem is to realize the closed-loop supply chain and building reverse logistics system is of great significance.
The evaluation of (social-)psychological comfort in clothing, a possible approach
NASA Astrophysics Data System (ADS)
Matté, L. L.; Broega, A. C.
2017-10-01
This paper presents the first results of a PhD research on psychological comfort of clothing. In order to understand and conceptualize the psychological aspects of clothing comfort, a variation of the Delphi Method was used to seek opinions from experts. This method was chosen because of its consensus-building features. The results were obtained from a qualitative text analysis, conducted over the experts’ responses to the first round of questions. The analytic process shed some light on the formation of the psychological comfort concept as well as the potential attributes to be evaluated when assessing this comfort dimension.
Bastianoni, Simone; Galli, Alessandro; Pulselli, Riccardo Maria; Niccolucci, Valentina
2007-11-01
This paper focuses on appropriation of natural capital through construction of buildings. The ecological footprint and the Costanza natural capital concepts are applied. The environmental consequences of human settlement are currently of great concern, and a need is felt to reduce the impact of building on the environment. The embodied energy of building materials and the "land area" required to sustain their production are considered to evaluate the demand on nature of this activity. The ecological footprints of 2 typical Italian buildings are compared. The paper also focuses on how to reduce the natural capital appropriation of building construction by means of environmentally inexpensive materials, renewable energy resources, and optimization of the use of bioproductive land by construction of multistoried buildings. Finally, to allocate an environmental load of buildings, an economic evaluation of natural capital appropriation through building construction is proposed.
Energy and exergy assessments for an enhanced use of energy in buildings
NASA Astrophysics Data System (ADS)
Goncalves, Pedro Manuel Ferreira
Exergy analysis has been found to be a useful method for improving the conversion efficiency of energy resources, since it helps to identify locations, types and true magnitudes of wastes and losses. It has also been applied for other purposes, such as distinguishing high- from low-quality energy sources or defining the engineering technological limits in designing more energy-efficient systems. In this doctoral thesis, the exergy analysis is widely applied in order to highlight and demonstrate it as a significant method of performing energy assessments of buildings and related energy supply systems. It aims to make the concept more familiar and accessible for building professionals and to encourage its wider use in engineering practice. Case study I aims to show the importance of exergy analysis in the energy performance assessment of eight space heating building options evaluated under different outdoor environmental conditions. This study is concerned with the so-called "reference state", which in this study is calculated using the average outdoor temperature for a given period of analysis. Primary energy and related exergy ratios are assessed and compared. Higher primary exergy ratios are obtained for low outdoor temperatures, while the primary energy ratios are assumed as constant for the same scenarios. The outcomes of this study demonstrate the significance of exergy analysis in comparison with energy analysis when different reference states are compared. Case study II and Case study III present two energy and exergy assessment studies applied to a hotel and a student accommodation building, respectively. Case study II compares the energy and exergy performance of the main end uses of a hotel building located in Coimbra in central Portugal, using data derived from an energy audit. Case study III uses data collected from energy utilities bills to estimate the energy and exergy performance associated to each building end use. Additionally, a set of energy supply options are proposed and assessed as primary energy demand and exergy efficiency, showing it as a possible benchmarking method for future legislative frameworks regarding the energy performance assessment of buildings. Case study IV proposes a set of complementary indicators for comparing cogeneration and separate heat and electricity production systems. It aims to identify the advantages of exergy analysis relative to energy analysis, giving particular examples where these advantages are significant. The results demonstrate that exergy analysis can reveal meaningful information that might not be accessible using a conventional energy analysis approach, which is particularly evident when cogeneration and separated systems provide heat at very different temperatures. Case study V follows the exergy analysis method to evaluate the energy and exergy performance of a desiccant cooling system, aiming to assess and locate irreversibilities sources. The results reveal that natural gas boiler is the most inefficient component of the plant in question, followed by the chiller and heating coil. A set of alternative heating supply options for desiccant wheel regeneration is proposed, showing that, while some renewables may effectively reduce the primary energy demand of the plant, although this may not correspond to the optimum level of exergy efficiency. The thermal and chemical exergy components of moist air are also evaluated, as well as, the influence of outdoor environmental conditions on the energy/exergy performance of the plant. This research provides knowledge that is essential for the future development of complementary energy- and exergy-based indicators, helping to improve the current methodologies on performance assessments of buildings, cogeneration and desiccant cooling systems. The significance of exergy analysis is demonstrated for different types of buildings, which may be located in different climates (reference states) and be supplied by different types of energy sources. (Abstract shortened by ProQuest.).
Can a Library Building's Design Cue New Behaviors? A Case Study
ERIC Educational Resources Information Center
O'Kelly, Mary; Scott-Webber, Lennie; Garrison, Julie; Meyer, Kristin
2017-01-01
This study explores the relationship between architecture and interior space on student engagement at a newly constructed academic library. Using an action, mixed-methods approach with a convenience sample, researchers evaluated 744 photographs, 125 behavioral observations, and six group interviews. Analysis revealed four key attributes of…
Volatile organic compound emissions from engineered wood products
Steve Zylkowski; Charles Frihart
2017-01-01
Thirteen bonded engineered wood products representing those commonly used in building construction were evaluated for volatile organic chemicals using methods developed for interior bonded wood products. Although formaldehyde and acetaldehyde were emitted from all samples, they were not the dominant volatiles, which greatly depended on wood species and bonding...
Richard Everett; Paul Hessburg; Mark Jensen; Bernard Bormann
1994-01-01
This report responds to the request by Speaker Foley and Senator Hatfield for a scientific evaluation of the effects of Forest Service management practices on the sustainability of eastern Oregon and Washington ecosystems. The report recommends analysis methods and management practices that can be used to build an experimental approach to the restoration of stressed...
ERIC Educational Resources Information Center
American Association of School Administrators, Arlington, VA.
Presented is a study identifying and evaluating opportunities for decreasing energy use at Hindman Elementary School, Hindman, Kentucky. Methods used in this engineering investigation include building surveys, computer simulations and cost estimates. Findings revealed that modifications to the school's boiler, temperature controls, electrical…
Evaluating Outdoor Experiential Training for Leadership and Team Building.
ERIC Educational Resources Information Center
Williams, Scott D.; Graham, T. Scott; Baker, Bud
2003-01-01
Presents a model for calculating the return on investment in outdoor experiential training that focuses on pre- and posttraining behavior and business performance. Includes a method for converting data on turnover, absenteeism, productivity, quality, and job performance into monetary values to compute return. (Contains 54 references.) (SK)
Lysimetric evaluation of eddy covariance and scitillometer systems for the Texas High Plains
USDA-ARS?s Scientific Manuscript database
Evapotranspiration (ET) is an important component in the water budget and used extensively in water planning and irrigation scheduling. Although lysimetry is considered the most accurate method for crop water use measurements, large precision weighing lysimeters are expensive to build and operate. A...
20171130_Ind Ergo Report_631 DI Water Movement Process.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rivera, Cynthia R.
Perform an industrial ergonomic assessment to evaluate the new procedures for filling, lifting, and delivering high purity de-ionized water to building 9925. The goal was to improve on the previous method by minimizing/eliminating as much lifting and bending as possible to reduce the potential for overexertion-related injuries.
Some Basics for Teaching and Evaluating Energy Conservation in the Home
ERIC Educational Resources Information Center
McColl, Robert W.
1978-01-01
Examines methods for determining thermal efficiency and measuring heat loss in the home. Suggests ways to conserve energy based upon (1) climatic environment and its impact on a structure, (2) physical location of buildings and their microclimate, and (3) behavior modification of the inhabitants. (Author)
Motivational Signage Increases Physical Activity on a College Campus
ERIC Educational Resources Information Center
Ford, M. Allison; Torok, Donald
2008-01-01
Objective: The authors evaluated whether motivational signage influenced rates of stair use relative to elevator use on a college campus. Participants: In March and April 2004, the authors observed students, faculty, staff, and any visitors accessing a college campus building. Methods: During Phase I, the authors monitored ascending stair and…
Exploring the Effectiveness of a Retreat Method for Extension Staff
ERIC Educational Resources Information Center
Worker, Steven M.; Hill, Russell D.; Miller, JoLynn C.; Go, Charles G.; Boyes, Rita J.
2015-01-01
The California 4-H Association hosted two retreats to support its members with goals of balancing professional development with intentional relationship building. Evaluations demonstrated that staff found the intentional balance of time spent in unstructured, semi-structured, and structured time offered opportunities to grow professionally while…
Volden, Gro Holst
2018-08-01
Infrastructure projects in developed countries are rarely evaluated ex-post. Despite their number and scope, our knowledge about their various impacts is surprisingly limited. The paper argues that such projects must be assessed in a broad perspective that includes both operational, tactical and strategic aspects, and unintended as well as intended effects. A generic six-criteria evaluation framework is suggested, inspired by a framework frequently used to evaluate development assistance projects. It is tested on 20 Norwegian projects from various sectors (transport, defence, ICT, buildings). The results indicate that the majority of projects were successful, especially in operational terms, possibly because they underwent external quality assurance up-front. It is argued that applying this type of standardized framework provides a good basis for comparison and learning across sectors. It is suggested that evaluations should be conducted with the aim of promoting accountability, building knowledge about infrastructure projects, and continuously improve the tools, methods and governance arrangements used in the front-end of project development. Copyright © 2018 The Author. Published by Elsevier Ltd.. All rights reserved.
Data-driven modeling, control and tools for cyber-physical energy systems
NASA Astrophysics Data System (ADS)
Behl, Madhur
Energy systems are experiencing a gradual but substantial change in moving away from being non-interactive and manually-controlled systems to utilizing tight integration of both cyber (computation, communications, and control) and physical representations guided by first principles based models, at all scales and levels. Furthermore, peak power reduction programs like demand response (DR) are becoming increasingly important as the volatility on the grid continues to increase due to regulation, integration of renewables and extreme weather conditions. In order to shield themselves from the risk of price volatility, end-user electricity consumers must monitor electricity prices and be flexible in the ways they choose to use electricity. This requires the use of control-oriented predictive models of an energy system's dynamics and energy consumption. Such models are needed for understanding and improving the overall energy efficiency and operating costs. However, learning dynamical models using grey/white box approaches is very cost and time prohibitive since it often requires significant financial investments in retrofitting the system with several sensors and hiring domain experts for building the model. We present the use of data-driven methods for making model capture easy and efficient for cyber-physical energy systems. We develop Model-IQ, a methodology for analysis of uncertainty propagation for building inverse modeling and controls. Given a grey-box model structure and real input data from a temporary set of sensors, Model-IQ evaluates the effect of the uncertainty propagation from sensor data to model accuracy and to closed-loop control performance. We also developed a statistical method to quantify the bias in the sensor measurement and to determine near optimal sensor placement and density for accurate data collection for model training and control. Using a real building test-bed, we show how performing an uncertainty analysis can reveal trends about inverse model accuracy and control performance, which can be used to make informed decisions about sensor requirements and data accuracy. We also present DR-Advisor, a data-driven demand response recommender system for the building's facilities manager which provides suitable control actions to meet the desired load curtailment while maintaining operations and maximizing the economic reward. We develop a model based control with regression trees algorithm (mbCRT), which allows us to perform closed-loop control for DR strategy synthesis for large commercial buildings. Our data-driven control synthesis algorithm outperforms rule-based demand response methods for a large DoE commercial reference building and leads to a significant amount of load curtailment (of 380kW) and over $45,000 in savings which is 37.9% of the summer energy bill for the building. The performance of DR-Advisor is also evaluated for 8 buildings on Penn's campus; where it achieves 92.8% to 98.9% prediction accuracy. We also compare DR-Advisor with other data driven methods and rank 2nd on ASHRAE's benchmarking data-set for energy prediction.
NASA Astrophysics Data System (ADS)
Wang, Yongzhi; Ma, Yuqing; Zhu, A.-xing; Zhao, Hui; Liao, Lixia
2018-05-01
Facade features represent segmentations of building surfaces and can serve as a building framework. Extracting facade features from three-dimensional (3D) point cloud data (3D PCD) is an efficient method for 3D building modeling. By combining the advantages of 3D PCD and two-dimensional optical images, this study describes the creation of a highly accurate building facade feature extraction method from 3D PCD with a focus on structural information. The new extraction method involves three major steps: image feature extraction, exploration of the mapping method between the image features and 3D PCD, and optimization of the initial 3D PCD facade features considering structural information. Results show that the new method can extract the 3D PCD facade features of buildings more accurately and continuously. The new method is validated using a case study. In addition, the effectiveness of the new method is demonstrated by comparing it with the range image-extraction method and the optical image-extraction method in the absence of structural information. The 3D PCD facade features extracted by the new method can be applied in many fields, such as 3D building modeling and building information modeling.
Energy performance evaluation of AAC
NASA Astrophysics Data System (ADS)
Aybek, Hulya
The U.S. building industry constitutes the largest consumer of energy (i.e., electricity, natural gas, petroleum) in the world. The building sector uses almost 41 percent of the primary energy and approximately 72 percent of the available electricity in the United States. As global energy-generating resources are being depleted at exponential rates, the amount of energy consumed and wasted cannot be ignored. Professionals concerned about the environment have placed a high priority on finding solutions that reduce energy consumption while maintaining occupant comfort. Sustainable design and the judicious combination of building materials comprise one solution to this problem. A future including sustainable energy may result from using energy simulation software to accurately estimate energy consumption and from applying building materials that achieve the potential results derived through simulation analysis. Energy-modeling tools assist professionals with making informed decisions about energy performance during the early planning phases of a design project, such as determining the most advantageous combination of building materials, choosing mechanical systems, and determining building orientation on the site. By implementing energy simulation software to estimate the effect of these factors on the energy consumption of a building, designers can make adjustments to their designs during the design phase when the effect on cost is minimal. The primary objective of this research consisted of identifying a method with which to properly select energy-efficient building materials and involved evaluating the potential of these materials to earn LEED credits when properly applied to a structure. In addition, this objective included establishing a framework that provides suggestions for improvements to currently available simulation software that enhance the viability of the estimates concerning energy efficiency and the achievements of LEED credits. The primary objective was accomplished by using conducting several simulation models to determine the relative energy efficiency of wood-framed, metal-framed, and Aerated Autoclaved Concrete (AAC) wall structures for both commercial and residential buildings.
Rhode Island Model Evaluation & Support System: Building Administrator. Edition III
ERIC Educational Resources Information Center
Rhode Island Department of Education, 2015
2015-01-01
Rhode Island educators believe that implementing a fair, accurate, and meaningful educator evaluation and support system will help improve teaching, learning, and school leadership. The primary purpose of the Rhode Island Model Building Administrator Evaluation and Support System (Rhode Island Model) is to help all building administrators improve.…
2014-10-01
variability with well trained readers. Figure 7: comparison between the PD (percent density using Cumulus area) and the automatic PD. The...evaluation of outlier correction, comparison of several different software methods, precision measurement, and evaluation of variation by mammography...chart review for selected cases (month 4-6). Comparison of information from the Breast Cancer Database and medical records showed good consistency
VIIRS Product Evaluation at the Ocean PEATE
NASA Technical Reports Server (NTRS)
Patt, Frederick S.; Feldman, Gene C.
2010-01-01
The National Polar-orbiting Operational Environmental Satellite System (NPOESS) Preparatory Project (NPP) mission will support the continuation of climate records generated from NASA missions. The NASA Science Data Segment (SDS) relies upon discipline-specific centers of expertise to evaluate the NPP data products for suitability as climate data records, The Ocean Product Evaluation and Analysis Tool Element (PEATE) will build upon Well established NASA capabilities within the Ocean Color program in order to evaluate the NPP Visible and Infrared Imager/Radiometer Suite (VIIRS) Ocean Color and Chlorophyll data products. The specific evaluation methods will support not only the evaluation of product quality but also the sources of differences with existing data records.
NASA Technical Reports Server (NTRS)
Zhou, Yuyu; Weng, Qihao; Gurney, Kevin R.; Shuai, Yanmin; Hu, Xuefei
2012-01-01
This paper examined the relationship between remotely sensed anthropogenic heat discharge and energy use from residential and commercial buildings across multiple scales in the city of Indianapolis, Indiana, USA. The anthropogenic heat discharge was estimated with a remote sensing-based surface energy balance model, which was parameterized using land cover, land surface temperature, albedo, and meteorological data. The building energy use was estimated using a GIS-based building energy simulation model in conjunction with Department of Energy/Energy Information Administration survey data, the Assessor's parcel data, GIS floor areas data, and remote sensing-derived building height data. The spatial patterns of anthropogenic heat discharge and energy use from residential and commercial buildings were analyzed and compared. Quantitative relationships were evaluated across multiple scales from pixel aggregation to census block. The results indicate that anthropogenic heat discharge is consistent with building energy use in terms of the spatial pattern, and that building energy use accounts for a significant fraction of anthropogenic heat discharge. The research also implies that the relationship between anthropogenic heat discharge and building energy use is scale-dependent. The simultaneous estimation of anthropogenic heat discharge and building energy use via two independent methods improves the understanding of the surface energy balance in an urban landscape. The anthropogenic heat discharge derived from remote sensing and meteorological data may be able to serve as a spatial distribution proxy for spatially-resolved building energy use, and even for fossil-fuel CO2 emissions if additional factors are considered.
Sun, Xiaobo; Zimmermann, Carolyn M; Jackson, Glen P; Bunker, Christopher E; Harrington, Peter B
2011-01-30
A fast method that can be used to classify unknown jet fuel types or detect possible property changes in jet fuel physical properties is of paramount interest to national defense and the airline industries. While fast gas chromatography (GC) has been used with conventional mass spectrometry (MS) to study jet fuels, fast GC was combined with fast scanning MS and used to classify jet fuels into lot numbers or origin for the first time by using fuzzy rule-building expert system (FuRES) classifiers. In the process of building classifiers, the data were pretreated with and without wavelet transformation and evaluated with respect to performance. Principal component transformation was used to compress the two-way data images prior to classification. Jet fuel samples were successfully classified with 99.8 ± 0.5% accuracy for both with and without wavelet compression. Ten bootstrapped Latin partitions were used to validate the generalized prediction accuracy. Optimized partial least squares (o-PLS) regression results were used as positively biased references for comparing the FuRES prediction results. The prediction results for the jet fuel samples obtained with these two methods were compared statistically. The projected difference resolution (PDR) method was also used to evaluate the fast GC and fast MS data. Two batches of aliquots of ten new samples were prepared and run independently 4 days apart to evaluate the robustness of the method. The only change in classification parameters was the use of polynomial retention time alignment to correct for drift that occurred during the 4-day span of the two collections. FuRES achieved perfect classifications for four models of uncompressed three-way data. This fast GC/fast MS method furnishes characteristics of high speed, accuracy, and robustness. This mode of measurement may be useful as a monitoring tool to track changes in the chemical composition of fuels that may also lead to property changes. Copyright © 2010 Elsevier B.V. All rights reserved.
A Protocol for Lifetime Energy and Environmental Impact Assessment of Building Insulation Materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shrestha, Som S; Biswas, Kaushik; Desjarlais, Andre Omer
This article describes a proposed protocol that is intended to provide a comprehensive list of factors to be considered in evaluating the direct and indirect environmental impacts of building insulation materials, as well as detailed descriptions of standardized calculation methodologies to determine those impacts. The energy and environmental impacts of insulation materials can generally be divided into two categories: (1) direct impact due to the embodied energy of the insulation materials and other factors, and (2) indirect or environmental impacts avoided as a result of reduced building energy use due to addition of insulation. Standards and product category rules existmore » that provide guidelines about the life cycle assessment (LCA) of materials, including building insulation products. However, critical reviews have suggested that these standards fail to provide complete guidance to LCA studies and suffer from ambiguities regarding the determination of the environmental impacts of building insulation and other products. The focus of the assessment protocol described here is to identify all factors that contribute to the total energy and environmental impacts of different insulation products and, more importantly, provide standardized determination methods that will allow comparison of different insulation material types. Further, the intent is not to replace current LCA standards but to provide a well-defined, easy-to-use comparison method for insulation materials using existing LCA guidelines.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1984-03-01
The objectives of the analysis are to evaluate the application of a number of building automation system capabilities using the Park Plaza Building as a case study. The study looks at the energy and cost effectiveness of some energy management strategies of the building automation system as well as some energy management strategies that are not currently a part of the building automation system. The strategies are also evaluated in terms of their reliability and usefulness in this building.
O'Donnell, Andrew P.; Kurama, Yahya C.; Kalkan, Erol; Taflanidis, Alexandros A.
2017-01-01
This paper experimentally evaluates four methods to scale earthquake ground-motions within an ensemble of records to minimize the statistical dispersion and maximize the accuracy in the dynamic peak roof drift demand and peak inter-story drift demand estimates from response-history analyses of nonlinear building structures. The scaling methods that are investigated are based on: (1) ASCE/SEI 7–10 guidelines; (2) spectral acceleration at the fundamental (first mode) period of the structure, Sa(T1); (3) maximum incremental velocity, MIV; and (4) modal pushover analysis. A total of 720 shake-table tests of four small-scale nonlinear building frame specimens with different static and dynamic characteristics are conducted. The peak displacement demands from full suites of 36 near-fault ground-motion records as well as from smaller “unbiased” and “biased” design subsets (bins) of ground-motions are included. Out of the four scaling methods, ground-motions scaled to the median MIV of the ensemble resulted in the smallest dispersion in the peak roof and inter-story drift demands. Scaling based on MIValso provided the most accurate median demands as compared with the “benchmark” demands for structures with greater nonlinearity; however, this accuracy was reduced for structures exhibiting reduced nonlinearity. The modal pushover-based scaling (MPS) procedure was the only method to conservatively overestimate the median drift demands.
NASA Astrophysics Data System (ADS)
Li, Cunbin; Wang, Yi; Lin, Shuaishuai
2017-09-01
With the rapid development of the energy internet and the deepening of the electric power reform, the traditional marketing mode of electric power does not apply to most of electric power enterprises, so must seek a breakthrough, however, in the face of increasingly complex marketing information, how to make a quick, reasonable transformation, makes the electric power marketing competitiveness assessment more accurate and objective becomes a big problem. In this paper, cloud model and TOPSIS method is proposed. Firstly, build the electric power marketing competitiveness evaluation index system. Then utilize the cloud model to transform the qualitative evaluation of the marketing data into quantitative values and use the entropy weight method to weaken the subjective factors of evaluation index weight. Finally, by TOPSIS method the closeness degrees of alternatives are obtained. This method provides a novel solution for the electric power marketing competitiveness evaluation. Through the case analysis the effectiveness and feasibility of this model are verified.
A novel HVSR approach on structural heath monitoring for structural vulnerability assesement
NASA Astrophysics Data System (ADS)
Pentaris, Fragkiskos P.; Papadopoulos, Ilias
2014-05-01
This work suggests a novel approach for vulnerability assessment in structural health monitoring (SHM) through Horizontal to Vertical Spectral Ratio (HVSR) method. Acceleration recordings of different age concrete buildings [1] are analyzed using the conventional method for estimation of fundamental frequency in SHM (Fast Furrier Transform-FFT method). The results of frequency spectrum are verified theoretically (mass and stiffness matrices models) but also by practical techniques applied in real structure data, for the estimation of structural resonance frequencies [2-4]. The same recordings are analyzed by HVSR method and study the differences and the similarities of both methods (FFT and HVSR) under earthquake excitation. Both methods can reveal resonance frequencies and amplitude of buildings under study, with great detail and efficiency in terms of ease of deployment, computation, cost and time. Furthermore HVSR recordings of strong seismic motion are compared with HVSR recordings of ambient noise for the case study buildings. The similarities of HVSR recordings (between earthquake and ambient noise) reveal the same analogy in HVSR spectrum. This enables a simple HVSR noise recording in a building to present the same information with an earthquake HVSR recording that are much rarer. This study presents a novel index which compute the increase of HVSR between floors and correlates the increasing rate with the structural vulnerability of the specific building. The main idea is that this HVSR rate index is strongly related with the differential acceleration (between floors), a determinant measurement for SHM assessment in concrete buildings. Experimental data verify the above HVSR rise index by presentation of higher HVSR rise in older buildings (with visible cracks in beams, damage and stress in their structure) than other younger buildings without any visible damage. Acknowledgments This work was supported in part by the ARCHEMEDES III Program of the Ministry of Education of Greece and the European Union in the framework of the project entitled «Interdisciplinary Multi-Scale Research of Earthquake Physics and Seismotectonics at the front of the Hellenic Arc (IMPACT-ARC) ». References [1] F. P. Pentaris, J. Stonham, and J. P. Makris, "A review of the state-of-the-art of wireless SHM systems and an experimental set-up towards an improved design," presented at the EUROCON, 2013 IEEE, Zagreb, 2013. [2] R. Ditommaso, M. Mucciarelli, S. Parolai, and M. Picozzi, "Monitoring the structural dynamic response of a masonry tower: Comparing classical and time-frequency analyses," Bulletin of Earthquake Engineering, vol. 10, pp. 1221-1235, 2012. [3] Sungkono, D. D. Warnana, Triwulan, and W. Utama, "Evaluation of Buildings Strength from Microtremor Analyses " International Journal of Civil & Environmental Engineering IJCEE-IJENS, vol. 11, 2011. [4] L.-L. Hong and W.-L. Hwang, "Empirical formula for fundamental vibration periods of reinforced concrete buildings in Taiwan," Earthquake Engineering & Structural Dynamics, vol. 29, pp. 327-337, 2000.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Levy, E.; Mullens, M.; Rath, P.
The Advanced Envelope Research effort will provide factory homebuilders with high performance, cost-effective envelope designs that can be effectively integrated into the plant production process while meeting the thermal requirements of the 2012 IECC standards. This work is part of a multiphase effort. Phase 1 identified seven envelope technologies and provided a preliminary assessment of three methods for building high performance walls. Phase 2 focused on developing viable product designs, manufacturing strategies, addressing code and structural issues, and cost analysis of the three selected options. An industry advisory committee helped narrow the research focus to perfecting a stud wall designmore » with exterior continuous insulation (CI). This report describes Phase 3, which was completed in two stages and continued the design development effort, exploring and evaluating a range or methods for applying CI to factory built homes. The scope also included material selection, manufacturing and cost analysis, and prototyping and testing. During this phase, a home was built with CI, evaluated, and placed in service. The experience of building a mock up wall section with CI and then constructing on line a prototype home resolved important concerns about how to integrate the material into the production process. First steps were taken toward finding least expensive approaches for incorporating CI in standard factory building practices and a preliminary assessment suggested that even at this early stage the technology is attractive when viewed from a life cycle cost perspective.« less
Streamlining Building Efficiency Evaluation with DOE's Asset Score Preview
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goel, Supriya; Wang, Nora; Gonzalez, Juan
2016-08-26
Building Energy Asset Score (Asset Score), developed by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE), is a tool to help building owners and managers assess the efficiency of a building's energy-related systems and encourage investment in cost-effective improvements. The Asset Score uses an EnergyPlus model to provide a quick assessment of building energy performance with minimum user inputs of building characteristics and identifies upgrade opportunities. Even with a reduced set of user inputs, data collection remains a challenge for wide-spread adoption, especially when evaluating a large number of buildings. To address this, Asset Scoremore » Preview was developed to allow users to enter as few as seven building characteristics to quickly assess their buildings before a more in-depth analysis. A streamlined assessment from Preview to full Asset Score provides an easy entry point and also enables users who manage a large number of buildings to screen and prioritize buildings that can benefit most from a more detailed evaluation and possible energy efficiency upgrades without intensive data collection.« less
Feasibility analysis on the building environment of college dormitories in Baoding
NASA Astrophysics Data System (ADS)
Wang, Xinyi
2018-06-01
The quality of indoor air greatly affects people's health. As a place where college students live for a long time, the architectural environment is closely related to people's lives. In this paper, two cases of dormitory of the North China Electric Power University in Baoding are selected as the subject investigated. The environmental test and questionnaire method were used to study. The test indexes mainly include temperature, relative humidity and wind speeds. We obtain the basic situation of indoor thermal humidity environment, light environment and air velocity. Based on a series of tests, combined with subjective comfort and comprehensive evaluation, we analyzed the thermal comfort of indoor buildings, and put forward measures to further improve the building environment of College Dormitories under the principle of high efficiency and energy saving.
Building environment assessment and energy consumption estimation using smart phones
NASA Astrophysics Data System (ADS)
Li, Xiangli; Zhang, Li; Jia, Yingqi; Wang, Zihan; Jin, Xin; Zhao, Xuefeng
2017-04-01
In this paper, an APP for building indoor environment evaluation and energy consumption estimation based on Android platform is proposed and established. While using the APP, the smart phone built-in sensors are called for real-time monitoring of the building environmental information such as temperature, humidity and noise, etc. the built-in algorithm is developed to calculate the heat and power consumption, and questionnaires, grading and other methods are used to feed back to the space heating system. In addition, with the application of the technology of big data and cloud technology, the data collected by users will be uploaded to the cloud. After the statistics of the uploaded data, regional difference can be obtained, thus providing a more accurate basis for macro-control and research of energy, thermal comfort, greenhouse effect.
A Bayesian prediction model between a biomarker and the clinical endpoint for dichotomous variables.
Jiang, Zhiwei; Song, Yang; Shou, Qiong; Xia, Jielai; Wang, William
2014-12-20
Early biomarkers are helpful for predicting clinical endpoints and for evaluating efficacy in clinical trials even if the biomarker cannot replace clinical outcome as a surrogate. The building and evaluation of an association model between biomarkers and clinical outcomes are two equally important concerns regarding the prediction of clinical outcome. This paper is to address both issues in a Bayesian framework. A Bayesian meta-analytic approach is proposed to build a prediction model between the biomarker and clinical endpoint for dichotomous variables. Compared with other Bayesian methods, the proposed model only requires trial-level summary data of historical trials in model building. By using extensive simulations, we evaluate the link function and the application condition of the proposed Bayesian model under scenario (i) equal positive predictive value (PPV) and negative predictive value (NPV) and (ii) higher NPV and lower PPV. In the simulations, the patient-level data is generated to evaluate the meta-analytic model. PPV and NPV are employed to describe the patient-level relationship between the biomarker and the clinical outcome. The minimum number of historical trials to be included in building the model is also considered. It is seen from the simulations that the logit link function performs better than the odds and cloglog functions under both scenarios. PPV/NPV ≥0.5 for equal PPV and NPV, and PPV + NPV ≥1 for higher NPV and lower PPV are proposed in order to predict clinical outcome accurately and precisely when the proposed model is considered. Twenty historical trials are required to be included in model building when PPV and NPV are equal. For unequal PPV and NPV, the minimum number of historical trials for model building is proposed to be five. A hypothetical example shows an application of the proposed model in global drug development. The proposed Bayesian model is able to predict well the clinical endpoint from the observed biomarker data for dichotomous variables as long as the conditions are satisfied. It could be applied in drug development. But the practical problems in applications have to be studied in further research.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-03
... for OMB Review; Comment Request; Impact Evaluation of the YouthBuild Program ACTION: Notice. SUMMARY... proposal for a new information collection titled, ``Impact Evaluation of the YouthBuild Program,'' to the... support of an impact evaluation of the YouthBuild Program. Specifically, the DOL seeks to conduct a census...
Analysis of physical activity mass media campaign design.
Lankford, Tina; Wallace, Jana; Brown, David; Soares, Jesus; Epping, Jacqueline N; Fridinger, Fred
2014-08-01
Mass media campaigns are a necessary tool for public health practitioners to reach large populations and promote healthy behaviors. Most health scholars have concluded that mass media can significantly influence the health behaviors of populations; however the effects of such campaigns are typically modest and may require significant resources. A recent Community Preventive Services Task Force review on stand-alone mass media campaigns concluded there was insufficient evidence to determine their effectiveness in increasing physical activity, partly due to mixed methods and modest and inconsistent effects on levels of physical activity. A secondary analysis was performed on the campaigns evaluated in the Task Force review to determine use of campaign-building principles, channels, and levels of awareness and their impact on campaign outcomes. Each study was analyzed by 2 reviewers for inclusion of campaign building principles. Campaigns that included 5 or more campaign principles were more likely to be successful in achieving physical activity outcomes. Campaign success is more likely if the campaign building principles (formative research, audience segmentation, message design, channel placement, process evaluation, and theory-based) are used as part of campaign design and planning.
Shaw, James; Kearney, Colleen; Glenns, Brenda; McKay, Sandra
2016-01-01
Home-based palliative care is increasingly dependent on interprofessional teams to deliver collaborative care that more adequately meets the needs of clients and families. The purpose of this pilot evaluation was to qualitatively explore the views of an interprofessional group of home care providers (occupational therapists, nurses, personal support work supervisors, community care coordinators, and a team coordinator) regarding a pilot project encouraging teamwork in interprofessional palliative home care services. We used qualitative methods, informed by an interprofessional conceptual framework, to analyse participants' accounts and provide recommendations regarding strategies for interprofessional team building in palliative home health care. Findings suggest that encouraging practitioners to share past experiences and foster common goals for palliative care are important elements of team building in interprofessional palliative care. Also, establishing a team leader who emphasises sharing power among team members and addressing the need for mutual emotional support may help to maximise interprofessional teamwork in palliative home care. These findings may be used to develop and test more comprehensive efforts to promote stronger interprofessional teamwork in palliative home health care delivery.
NASA Astrophysics Data System (ADS)
He, Xianjin; Zhang, Xinchang; Xin, Qinchuan
2018-02-01
Recognition of building group patterns (i.e., the arrangement and form exhibited by a collection of buildings at a given mapping scale) is important to the understanding and modeling of geographic space and is hence essential to a wide range of downstream applications such as map generalization. Most of the existing methods develop rigid rules based on the topographic relationships between building pairs to identify building group patterns and thus their applications are often limited. This study proposes a method to identify a variety of building group patterns that allow for map generalization. The method first identifies building group patterns from potential building clusters based on a machine-learning algorithm and further partitions the building clusters with no recognized patterns based on the graph partitioning method. The proposed method is applied to the datasets of three cities that are representative of the complex urban environment in Southern China. Assessment of the results based on the reference data suggests that the proposed method is able to recognize both regular (e.g., the collinear, curvilinear, and rectangular patterns) and irregular (e.g., the L-shaped, H-shaped, and high-density patterns) building group patterns well, given that the correctness values are consistently nearly 90% and the completeness values are all above 91% for three study areas. The proposed method shows promises in automated recognition of building group patterns that allows for map generalization.
Comprehensive evaluation of global energy interconnection development index
NASA Astrophysics Data System (ADS)
Liu, Lin; Zhang, Yi
2018-04-01
Under the background of building global energy interconnection and realizing green and low-carbon development, this article constructed the global energy interconnection development index system which based on the current situation of global energy interconnection development. Through using the entropy method for the weight analysis of global energy interconnection development index, and then using gray correlation method to analyze the selected countries, this article got the global energy interconnection development index ranking and level classification.
Training Methods to Build Human Terrain Mapping Skills
2010-10-01
confidence in making friends, and talking to strangers. • Language – a few key phrases. • Language training with Arabic teacher (not computer -based...session to evaluate the lesson content and delivery method. Based on your feedback we will make changes and corrections to the content and the computer ...requirement, exemplar training materials were developed. The training materials took the form of a modular computer /web-based and web-deliverable course of
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mazloom, M.
2008-07-08
The idea of safe room has been developed for decreasing the earthquake casualties in masonry buildings. The information obtained from the previous ground motions occurring in seismic zones expresses the lack of enough safety of these buildings against earthquakes. For this reason, an attempt has been made to create some safe areas inside the existing masonry buildings, which are called safe rooms. The practical method for making these safe areas is to install some prefabricated steel frames in some parts of the existing structure. These frames do not carry any service loads before an earthquake. However, if a devastating earthquakemore » happens and the load bearing walls of the building are destroyed, some parts of the floors, which are in the safe areas, will fall on the roof of the installed frames and the occupants who have sheltered there will survive. This paper presents the performance of these frames located in a destroying three storey masonry building with favorable conclusions. In fact, the experimental pushover diagram of the safe room located at the ground-floor level of this building is compared with the analytical results and it is concluded that pushover analysis is a good method for seismic performance evaluation of safe rooms. For time history analysis the 1940 El Centro, the 2003 Bam, and the 1990 Manjil earthquake records with the maximum peak accelerations of 0.35g were utilized. Also the design spectrum of Iranian Standard No. 2800-05 for the ground kind 2 is used for response spectrum analysis. The results of time history, response spectrum and pushover analyses show that the strength and displacement capacity of the steel frames are adequate to accommodate the distortions generated by seismic loads and aftershocks properly.« less
Seismic damage diagnosis of a masonry building using short-term damping measurements
NASA Astrophysics Data System (ADS)
Kouris, Leonidas Alexandros S.; Penna, Andrea; Magenes, Guido
2017-04-01
It is of considerable importance to perform dynamic identification and detect damage in existing structures. This paper describes a new and practical method for damage diagnosis of masonry buildings requiring minimum computational effort. The method is based on the relative variation of modal damping and validated against experimental data from a full scale two storey shake table test. The experiment involves a building subjected to uniaxial vibrations of progressively increasing intensity at the facilities of EUCENTRE laboratory (Pavia, Italy) up to a near collapse damage state. Five time-histories are applied scaling the Montenegro (1979) accelerogram. These strong motion tests are preceded by random vibration tests (RVT's) which are used to perform modal analysis. Two deterministic methods are applied: the single degree of freedom (SDOF) assumption together with the peak-picking method in the discrete frequency domain and the Eigen realisation algorithm with data correlations (ERA-DC) in the discrete time domain. Regarding the former procedure, some improvements are incorporated to locate rigorously the natural frequencies and estimate the modal damping. The progressive evolution of the modal damping is used as a key indicator to characterise damage on the building. Modal damping is connected to the structural mass and stiffness. A square integrated but only with two components expression for proportional (classical) damping is proposed to fit better with the experimental measurements of modal damping ratios. Using this Rayleigh order formulation the contribution of each of the damping components is evaluated. The stiffness component coefficient is proposed as an effective index to detect damage and quantify its intensity.
Overview of the Building Assessment Survey and Evaluation Study
The Building Assessment Survey and Evaluation (BASE) study was conducted over a five-year period from 1994-1998, to characterize determinants of indoor air quality (IAQ) and occupant perceptions in representative public and commercial office buildings.
Empowerment evaluation: building communities of practice and a culture of learning.
Fetterman, David M
2002-02-01
Empowerment evaluation is the use of evaluation concepts, techniques, and findings to foster improvement and self-determination. Program participants--including clients--conduct their own evaluations: an outside evaluator often serves as a coach or additional facilitator depending on internal program capabilities. Empowerment evaluation has three steps: 1) establishing a mission; 2) taking stock; and 3) planning for the future. These three steps build capacity. They also build a sense of community, often referred to as communities of practice. Empowerment evaluation also helps to create a culture of learning and evaluation within an organization or community.
Assessing Graduate Attributes: Building a Criteria-Based Competency Model
ERIC Educational Resources Information Center
Ipperciel, Donald; ElAtia, Samira
2014-01-01
Graduate attributes (GAs) have become a necessary framework of reference for the 21st century competency-based model of higher education. However, the issue of evaluating and assessing GAs still remains unchartered territory. In this article, we present a criteria-based method of assessment that allows for an institution-wide comparison of the…
Big Data on a Smaller Scale: A Social Media Analytics Assignment
ERIC Educational Resources Information Center
Fischbach, Sarah; Zarzosa, Jennifer
2018-01-01
It is truly important for students to understand how to monitor online marketing buzz. This assignment, social media analytics, utilizes the content analysis research method to build student's in-depth understanding on how to evaluate and interpret user-generated content (UGC) to create social media campaigns. The authors adapted Resnik and…
Conflicts Management Model in School: A Mixed Design Study
ERIC Educational Resources Information Center
Dogan, Soner
2016-01-01
The object of this study is to evaluate the reasons for conflicts occurring in school according to perceptions and views of teachers and resolution strategies used for conflicts and to build a model based on the results obtained. In the research, explanatory design including quantitative and qualitative methods has been used. The quantitative part…
Evaluation of Controlled Vocabularies by Inter-Indexer Consistency
ERIC Educational Resources Information Center
Monreal, Concha Soler; Gil-Leiva, Isidoro
2011-01-01
Introduction: Several controlled vocabularies are used for indexing three journal articles to check if better or equal consistency rates are achieved with a list of descriptors than with a standard thesaurus and augmented thesaurus. Method: A terminology set for library and information Science was used to build a list of descriptors with…
Using Critical Appraisal to Inform Program Improvement
ERIC Educational Resources Information Center
Esterlund, Theresa; Krantz, Amanda; Sigmond, Catherine
2017-01-01
In 2016, the education department at the National Building Museum offered a series of Late Night programs in conjunction with the Summer Block Party installation, ICEBERGS. The museum wanted to evaluate the programs but had limited resources to do so. In the following article, we describe the use of critical appraisal, an economic method applied…
This report describes the results of an investigation conducted to assist EPA’s New England Regional Office in evaluating vapor intrusion at 15 homes and one commercial building near the Raymark Superfund Site in Stratford, Connecticut. Methods were developed to sample sub-slab ...
Code of Federal Regulations, 2011 CFR
2011-04-01
... guidelines in any quality assurance review: (1) ASQC Q9000-1-1994 Quality Management and Quality Assurance... Systems—Model for Quality Assurance in Final Inspection and Test; (5) ASQC Q9004-1-1994 Quality Management... in interpreting testing standards, test methods, evaluating test reports and quality control programs...
Multi-Armed RCTs: A Design-Based Framework. NCEE 2017-4027
ERIC Educational Resources Information Center
Schochet, Peter Z.
2017-01-01
Design-based methods have recently been developed as a way to analyze data from impact evaluations of interventions, programs, and policies (Imbens and Rubin, 2015; Schochet, 2015, 2016). The estimators are derived using the building blocks of experimental designs with minimal assumptions, and are unbiased and normally distributed in large samples…
Togetherness, Teamwork and Challenges: "Reflections on Building an Inclusive Research Network"
ERIC Educational Resources Information Center
Riches, Tanya N.; O'Brien, Patricia M.
2017-01-01
Background: This article presents a case study of the Centre for Disability Studies' Inclusive Research Network. The network is a dynamic group of around fifteen people who have intellectual and other disabilities, support workers and university researchers. Methods: The study was based upon an evaluation of the group's research practice, as…
Evaluation of ground motion scaling methods for analysis of structural systems
O'Donnell, A. P.; Beltsar, O.A.; Kurama, Y.C.; Kalkan, E.; Taflanidis, A.A.
2011-01-01
Ground motion selection and scaling comprises undoubtedly the most important component of any seismic risk assessment study that involves time-history analysis. Ironically, this is also the single parameter with the least guidance provided in current building codes, resulting in the use of mostly subjective choices in design. The relevant research to date has been primarily on single-degree-of-freedom systems, with only a few studies using multi-degree-of-freedom systems. Furthermore, the previous research is based solely on numerical simulations with no experimental data available for the validation of the results. By contrast, the research effort described in this paper focuses on an experimental evaluation of selected ground motion scaling methods based on small-scale shake-table experiments of re-configurable linearelastic and nonlinear multi-story building frame structure models. Ultimately, the experimental results will lead to the development of guidelines and procedures to achieve reliable demand estimates from nonlinear response history analysis in seismic design. In this paper, an overview of this research effort is discussed and preliminary results based on linear-elastic dynamic response are presented. ?? ASCE 2011.
NASA Astrophysics Data System (ADS)
Van Eester, Dirk
2005-03-01
A semi-analytical method is proposed to evaluate the dielectric response of a plasma to electromagnetic waves in the ion cyclotron domain of frequencies in a D-shaped but axisymmetric toroidal geometry. The actual drift orbit of the particles is accounted for. The method hinges on subdividing the orbit into elementary segments in which the integrations can be performed analytically or by tabulation, and it relies on the local book-keeping of the relation between the toroidal angular momentum and the poloidal flux function. Depending on which variables are chosen, the method allows computation of elementary building blocks for either the wave or the Fokker-Planck equation, but the accent is mainly on the latter. Two types of tangent resonance are distinguished.
40. ARAIII Prototype assembly and evaluation building ARA630. East end ...
40. ARA-III Prototype assembly and evaluation building ARA-630. East end and south side of building. Camera facing west. Roof railing is part of demolition preparations. Building beyond ARA-622 is ARA-621. In left of view is reactor building. ARA-607 is low-roofed portion, while high-bay portion is ARA-608. Ineel photo no. 3-27. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
NASA Astrophysics Data System (ADS)
Kolobova, Svetlana
2018-03-01
As you know, high-rise construction is an indicator of the practical implementation of advanced innovative technologies in the construction industry of the country. High-rise building inevitably comes to the big cities, in connection with the shortage and value of land. The life cycle of any construction project, including high-rise buildings consists of chains: of engineering survey - design-construction-operation. In the process of operation of a tall building, decisions about major repairs or reconstruction of a building are made for decision-making on further use. This article describes methods of assessing the consumer quality of high-rise residential buildings and the establishment of prices based on consumer characteristics of a tall residential building. It is proposed to assess the premises under their quality characteristics. The study was conducted to establish the influence of individual, comprehensive and integral indicators of comparable quality for effective quality living spaces. Simultaneously, there was established a relationship of quality with the consumer cost of housing, ultimately with the potential needs of owners, tenants of the home, lessor dwelling, or buyers of residential properties and other participants in the residential real estate market. This relationship further creates consumer requirements to quality standard of premises at a certain stage of socio-economic development.
Applications of system dynamics modelling to support health policy.
Atkinson, Jo-An M; Wells, Robert; Page, Andrew; Dominello, Amanda; Haines, Mary; Wilson, Andrew
2015-07-09
The value of systems science modelling methods in the health sector is increasingly being recognised. Of particular promise is the potential of these methods to improve operational aspects of healthcare capacity and delivery, analyse policy options for health system reform and guide investments to address complex public health problems. Because it lends itself to a participatory approach, system dynamics modelling has been a particularly appealing method that aims to align stakeholder understanding of the underlying causes of a problem and achieve consensus for action. The aim of this review is to determine the effectiveness of system dynamics modelling for health policy, and explore the range and nature of its application. A systematic search was conducted to identify articles published up to April 2015 from the PubMed, Web of Knowledge, Embase, ScienceDirect and Google Scholar databases. The grey literature was also searched. Papers eligible for inclusion were those that described applications of system dynamics modelling to support health policy at any level of government. Six papers were identified, comprising eight case studies of the application of system dynamics modelling to support health policy. No analytic studies were found that examined the effectiveness of this type of modelling. Only three examples engaged multidisciplinary stakeholders in collective model building. Stakeholder participation in model building reportedly facilitated development of a common 'mental map' of the health problem, resulting in consensus about optimal policy strategy and garnering support for collaborative action. The paucity of relevant papers indicates that, although the volume of descriptive literature advocating the value of system dynamics modelling is considerable, its practical application to inform health policy making is yet to be routinely applied and rigorously evaluated. Advances in software are allowing the participatory model building approach to be extended to more sophisticated multimethod modelling that provides policy makers with more powerful tools to support the design of targeted, effective and equitable policy responses for complex health problems. Building capacity and investing in communication to promote these modelling methods, as well as documenting and evaluating their applications, will be vital to supporting uptake by policy makers.
Community-based research in action: tales from the Ktunaxa community learning centres project.
Stacy, Elizabeth; Wisener, Katherine; Liman, Yolanda; Beznosova, Olga; Lauscher, Helen Novak; Ho, Kendall; Jarvis-Selinger, Sandra
2014-01-01
Rural communities, particularly Aboriginal communities, often have limited access to health information, a situation that can have significant negative consequences. To address the lack of culturally and geographically relevant health information, a community-university partnership was formed to develop, implement, and evaluate Aboriginal Community Learning Centres (CLCs). The objective of this paper is to evaluate the community-based research process used in the development of the CLCs. It focuses on the process of building relationships among partners and the CLC's value and sustainability. Semistructured interviews were conducted with key stakeholders, including principal investigators, community research leads, and supervisors. The interview transcripts were analyzed using an open-coding process to identify themes. Key challenges included enacting shared project governance, negotiating different working styles, and hiring practices based on commitment to project objectives rather than skill set. Technological access provided by the CLCs increased capacity for learning and collective community initiatives, as well as building community leads' skills, knowledge, and self-efficacy. An important lesson was to meet all partners "where they are" in building trusting relationships and adapting research methods to fit the project's context and strengths. Successful results were dependent upon persistence and patience in working through differences, and breaking the project into achievable goals, which collectively contributed to trust and capacity building. The process of building these partnerships resulted in increased capacity of communities to facilitate learning and change initiatives, and the capacity of the university to engage in successful research partnerships with Aboriginal communities in the future.
Impact of Sustainable Cool Roof Technology on Building Energy Consumption
NASA Astrophysics Data System (ADS)
Vuppuluri, Prem Kiran
Highly reflective roofing systems have been analyzed over several decades to evaluate their ability to meet sustainability goals, including reducing building energy consumption and mitigating the urban heat island. Studies have isolated and evaluated the effects of climate, surface reflectivity, and roof insulation on energy savings, thermal load mitigation and also ameliorating the urban heat island. Other sustainable roofing systems, like green-roofs and solar panels have been similarly evaluated. The motivation for the present study is twofold: the first goal is to present a method for simultaneous evaluation and inter-comparison of multiple roofing systems, and the second goal is to quantitatively evaluate the realized heating and cooling energy savings associated with a white roof system compared to the reduction in roof-top heat flux. To address the first research goal a field experiment was conducted at the International Harvester Building located in Portland, OR. Thermal data was collected for a white roof, vegetated roof, and a solar panel shaded vegetated roof, and the heat flux through these roofing systems was compared against a control patch of conventional dark roof membrane. The second research goal was accomplished using a building energy simulation program to determine the impact of roof area and roof insulation on the savings from a white roof, in both Portland and Phoenix. The ratio of cooling energy savings to roof heat flux reduction from replacing a dark roof with a white roof was 1:4 for the month of July, and 1:5 annually in Portland. The COP of the associated chillers ranges from 2.8-4.2, indicating that the ratio of cooling energy savings to heat flux reduction is not accounted for solely by the COP of the chillers. The results of the building simulation indicate that based on energy savings alone, white roofs are not an optimal choice for Portland. The benefits associated with cooling energy savings relative to a black roof are offset by the winter-time penalty, and the net benefit from adopting white roof technology in Portland is small. That said, there are other potential benefits of white roofing such as impact on urban heat islands and roof life that must also be considered.
NASA Astrophysics Data System (ADS)
Malinowska, Agnieszka
2013-09-01
This paper is a continuation of theoretical analyses of World's methods used for assessing damage risk to buildings with continuous strains, which were presented in Part 1. The authors focus only on those methods in which the scale of damage to buildings can be approximated. Selected methods were tested on 100 random objects sited in hard coal excavation-induced areas. The efficiency and effectiveness of those methods was evaluated. The damage risk was also verified with the use of a method currently used in Poland. The efficiency results obtained for World's methods and the one used in Poland turned out to be comparable. Practical studies were made to evaluate the adaptability of those methods in the underground exploitation-induced conditions in Poland. Artykuł stanowi kontynuację badań teoretycznych zaprezentowanych w części pierwszej, dotyczących oceny możliwości wykorzystania metod stosowanych na świecie do oceny zagrożenia budynków deformacjami ciągłymi. Skoncentrowano się jedynie na metodach pozwalających na przybliżoną ocenę stopnia uszkodzenia obiektów. Wybrane metody przetestowano na 100 losowo wybranych obiektach z terenu poddanego wpływom eksploatacji węgla kamiennego. Przyjęty tok postępowania pozwolił na ocenę efektywności oraz skuteczności tych metod. Ocenę zagrożenia budynków przeprowadzono również przy wykorzystaniu metody stosowanej obecnie w Polsce. Wyniki ewaluacji zagrożenia metodami światowymi można było porównać z efektywnością Polskiej metody. Badania praktyczne pozwoliły na ocenę możliwości adaptacji tych metod w warunkach eksploatacji podziemnej w Polsce.
A novel orthoimage mosaic method using a weighted A∗ algorithm - Implementation and evaluation
NASA Astrophysics Data System (ADS)
Zheng, Maoteng; Xiong, Xiaodong; Zhu, Junfeng
2018-04-01
The implementation and evaluation of a weighted A∗ algorithm for orthoimage mosaic with UAV (Unmanned Aircraft Vehicle) imagery is proposed. The initial seam-line network is firstly generated by standard Voronoi Diagram algorithm; an edge diagram is generated based on DSM (Digital Surface Model) data; the vertices (conjunction nodes of seam-lines) of the initial network are relocated if they are on high objects (buildings, trees and other artificial structures); and the initial seam-lines are refined using the weighted A∗ algorithm based on the edge diagram and the relocated vertices. Our method was tested with three real UAV datasets. Two quantitative terms are introduced to evaluate the results of the proposed method. Preliminary results show that the method is suitable for regular and irregular aligned UAV images for most terrain types (flat or mountainous areas), and is better than the state-of-the-art method in both quality and efficiency based on the test datasets.
Before and after retrofit - response of a building during ambient and strong motions
Celebi, M.; Liu, Huaibao P.; ,
1998-01-01
This paper presents results obtained from ambient vibration and strong-motion responses of a thirteen-story, moment-resisting steel framed Santa Clara County Office Building (SCCOB) before being retrofitted by visco-elastic dampers and from ambient vibration response following the retrofit. Understanding the cumulative structural and site characteristics that affect the response of SCCOB before and after the retrofit is important in assessing earthquake hazards to other similar buildings and decision making in retrofitting them. The results emphasize the need to better evaluate structural and site characteristics in developing earthquake resisting designs that avoid resonating effects. Various studies of the strong-motion response records from the SCCOB during the 24 April 1984 (MHE) Morgan Hill (MS = 6.1), the 31 March 1986 (MLE) Mt. Lewis (MS = 6.1) and the 17 October 1989 (LPE) Loma Prieta (MS = 7.1) earthquakes show that the dynamic characteristics of the building are such that it (a) resonated (b) responded with a beating effect due to close-coupling of its translational and torsional frequencies, and (c) had a long-duration response due to low-damping. During each of these earthquakes, there was considerable contents damage and the occupants felt the rigorous vibration of the building. Ambient tests of SCCOB performed following LPE showed that both translational and torsional periods of the building are smaller than those derived from strong motions. Ambient tests performed following the retrofit of the building with visco-elastic dampers show that the structural fundamental mode frequency of the building has increased. The increased frequency implies a stiffer structure. Strong-motion response of the building during future earthquakes will ultimately validate the effectiveness of the retrofit method.This paper presents results obtained from ambient vibration and strong-motion responses of a thirteen-story, moment-resisting steel framed Santa Clara County Office Building (SCCOB) before being retrofitted by visco-elastic dampers and from ambient vibration response following the retrofit. Understanding the cumulative structural and site characteristics that affect the response of SCCOB before and after the retrofit is important in assessing earthquake hazards to other similar buildings and decision making in retrofitting them. The results emphasize the need to better evaluate structural and site characteristics in developing earthquake resisting designs that avoid resonating effects. Various studies of the strong-motion response records from the SCCOB during the 24 April 1984 (MHE) Morgan Hill (Ms = 6.1), the 31 March 1986 (MLE) Mt. Lewis (Ms = 6.1) and the 17 October 1989(LPE) Loma Prieta (Ms = 7.1) earthquakes show that the dynamic characteristics of the building are such that it (a) resonated (b) responded with a beating effect due to close-coupling of its translational and torsional frequencies, and (c) had a long-duration response due to low-damping. During each of these earthquakes, there was considerable contents damage and the occupants felt the rigorous vibration of the building. Ambient tests of SCCOB performed following LPE showed that both translational and torsional periods of the building are smaller than those derived from strong motions. Ambient tests performed following the retrofit of the building with visco-elastic dampers show that the structural fundamental mode frequency of the building has increased. The increased frequency implies a stiffer structure. Strong-motion response of the building during future earthquakes will ultimately validate the effectiveness of the retrofit method.
NASA Astrophysics Data System (ADS)
El-Dabaa, Rana; Abdelmohsen, Sherif
2018-05-01
The challenge in designing kinetic architecture lies in the lack of applying computational design and human computer interaction to successfully design intelligent and interactive interfaces. The use of ‘programmable materials’ as specifically fabricated composite materials that afford motion upon stimulation is promising for low-cost low-tech systems for kinetic facades in buildings. Despite efforts to develop working prototypes, there has been no clear methodological framework for understanding and controlling the behavior of programmable materials or for using them for such purposes. This paper introduces a methodology for evaluating the motion acquired from programmed material – resulting from the hygroscopic behavior of wood – through ‘motion grammar’. Motion grammar typically allows for the explanation of desired motion control in a computationally tractable method. The paper analyzed and evaluated motion parameters related to the hygroscopic properties and behavior of wood, and introduce a framework for tracking and controlling wood as a programmable material for kinetic architecture.
DOE Office of Scientific and Technical Information (OSTI.GOV)
TESP combines existing domain simulators in the electric power grid, with new transactive agents, growth models and evaluation scripts. The existing domain simulators include GridLAB-D for the distribution grid and single-family residential buildings, MATPOWER for transmission and bulk generation, and EnergyPlus for large buildings. More are planned for subsequent versions of TESP. The new elements are: TEAgents - simulate market participants and transactive systems for market clearing. Some of this functionality was extracted from GridLAB-D and implemented in Python for customization by PNNL and others; Growth Model - a means for simulating system changes over a multiyear period, including bothmore » normal load growth and specific investment decisions. Customizable in Python code; and Evaluation Script - a means of evaluating different transactive systems through customizable post-processing in Python code. TESP provides a method for other researchers and vendors to design transactive systems, and test them in a virtual environment. It allows customization of the key components by modifying Python code.« less
NASA Technical Reports Server (NTRS)
Stackhouse, Paul W., Jr.; Chandler, William S.; Hoell, James M.; Westberg, David; Zhang, Taiping
2015-01-01
Background: In the US, residential and commercial building infrastructure combined consumes about 40% of total energy usage and emits about 39% of total CO2 emission (DOE/EIA "Annual Energy Outlook 2013"). Building codes, as used by local and state enforcement entities are typically tied to the dominant climate within an enforcement jurisdiction classified according to various climate zones. These climate zones are based upon a 30-year average of local surface observations and are developed by DOE and ASHRAE. Establishing the current variability and potential changes to future building climate zones is very important for increasing the energy efficiency of buildings and reducing energy costs and emissions in the future. Objectives: This paper demonstrates the usefulness of using NASA's Modern Era Retrospective-analysis for Research and Applications (MERRA) atmospheric data assimilation to derive the DOE/ASHRAE building climate zone maps and then using MERRA to define the last 30 years of variability in climate zones for the Continental US. An atmospheric assimilation is a global atmospheric model optimized to satellite, atmospheric and surface in situ measurements. Using MERRA as a baseline, we then evaluate the latest Climate Model Inter-comparison Project (CMIP) climate model Version 5 runs to assess potential variability in future climate zones under various assumptions. Methods: We derive DOE/ASHRAE building climate zones using surface and temperature data products from MERRA. We assess these zones using the uncertainties derived by comparison to surface measurements. Using statistical tests, we evaluate variability of the climate zones in time and assess areas in the continental US for statistically significant trends by region. CMIP 5 produced a data base of over two dozen detailed climate model runs under various greenhouse gas forcing assumptions. We evaluate the variation in building climate zones for 3 different decades using an ensemble and quartile statistics to provide an assessment of potential building climate zone changes relative to the uncertainties demonstrated using MERRA. Findings and Conclusions: These results show that there is a statistically significant increase in the area covered by warmer climate zones and a tendency for a reduction of area in colder climate zones in some limited regions. The CMIP analysis shows that models vary from relatively little building climate zone change for the least sensitive and conservation assumptions to a warming of at most 3 zones for certain areas, particularly the north central US by the end of the 21st century.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2015-07-01
Air sealing of building enclosures is a difficult and time-consuming process. Current methods in new construction require laborers to physically locate small and sometimes large holes in multiple assemblies and then manually seal each of them. The innovation demonstrated under this research study was the automated air sealing and compartmentalization of buildings through the use of an aerosolized sealant, developed by the Western Cooling Efficiency Center at University of California Davis.CARB sought to demonstrate this new technology application in a multifamily building in Queens, NY. The effectiveness of the sealing process was evaluated by three methods: air leakage testing ofmore » overall apartment before and after sealing, point-source testing of individual leaks, and pressure measurements in the walls of the target apartment during sealing. Aerosolized sealing was successful by several measures in this study. Many individual leaks that are labor-intensive to address separately were well sealed by the aerosol particles. In addition, many diffuse leaks that are difficult to identify and treat were also sealed. The aerosol-based sealing process resulted in an average reduction of 71% in air leakage across three apartments and an average apartment airtightness of 0.08 CFM50/SF of enclosure area.« less
Structure-borne sound and vibration from building-mounted wind turbines
NASA Astrophysics Data System (ADS)
Moorhouse, Andy; Elliott, Andy; Eastwick, Graham; Evans, Tomos; Ryan, Andy; von Hunerbein, Sabine; le Bescond, Valentin; Waddington, David
2011-07-01
Noise continues to be a significant factor in the development of wind energy resources. In the case of building-mounted wind turbines (BMWTs), in addition to the usual airborne sound there is the potential for occupants to be affected by structure-borne sound and vibration transmitted through the building structure. Usual methods for prediction and evaluation of noise from large and small WTs are not applicable to noise of this type. This letter describes an investigation aiming to derive a methodology for prediction of structure-borne sound and vibration inside attached dwellings. Jointly funded by three UK government departments, the work was motivated by a desire to stimulate renewable energy generation by the removal of planning restrictions where possible. A method for characterizing BMWTs as sources of structure-borne sound was first developed during a field survey of two small wind turbines under variable wind conditions. The 'source strength' was established as a function of rotor speed although a general relationship to wind speed could not be established. The influence of turbulence was also investigated. The prediction methodology, which also accounts for the sound transmission properties of the mast and supporting building, was verified in a field survey of existing installations. Significant differences in behavior and subjective character were noted between the airborne and structure-borne noise from BMWTs.
Green Building Premium Cost Analysis in Indonesia Using Work Breakdown Structure Method
NASA Astrophysics Data System (ADS)
Basten, V.; Latief, Y.; Berawi, M. A.; Riswanto; Muliarto, H.
2018-03-01
The concept of green building in the construction industry is indispensable for mitigating environmental issues such as waste, pollution, and carbon emissions. There are some countries that have Green Building rating tools. Indonesia particularly is the country which has Greenship rating tools but the number of Green Building is relatively low. Development of building construction is depended on building investors or owner initiation, so this research is conducted to get the building aspects that have significant effect on the attractiveness using The Green Building Concept. The method in this research is work breakdown structure method that detailing the green building activities. The particular activities will be processed to get the cost elements for the green building achievement that it was targeted to improve better than conventional building. The final result of the study was a very significant work package on green building construction in the city of Indonesia case study.
Dannenberg, Andrew L; Bhatia, Rajiv; Cole, Brian L; Dora, Carlos; Fielding, Jonathan E; Kraft, Katherine; McClymont-Peace, Diane; Mindell, Jennifer; Onyekere, Chinwe; Roberts, James A; Ross, Catherine L; Rutt, Candace D; Scott-Samuel, Alex; Tilson, Hugh H
2006-02-01
Health impact assessment (HIA) methods are used to evaluate the impact on health of policies and projects in community design, transportation planning, and other areas outside traditional public health concerns. At an October 2004 workshop, domestic and international experts explored issues associated with advancing the use of HIA methods by local health departments, planning commissions, and other decisionmakers in the United States. Workshop participants recommended conducting pilot tests of existing HIA tools, developing a database of health impacts of common projects and policies, developing resources for HIA use, building workforce capacity to conduct HIAs, and evaluating HIAs. HIA methods can influence decisionmakers to adjust policies and projects to maximize benefits and minimize harm to the public's health.
Promoting evaluation capacity building in a complex adaptive system.
Lawrenz, Frances; Kollmann, Elizabeth Kunz; King, Jean A; Bequette, Marjorie; Pattison, Scott; Nelson, Amy Grack; Cohn, Sarah; Cardiel, Christopher L B; Iacovelli, Stephanie; Eliou, Gayra Ostgaard; Goss, Juli; Causey, Lauren; Sinkey, Anne; Beyer, Marta; Francisco, Melanie
2018-04-10
This study provides results from an NSF funded, four year, case study about evaluation capacity building in a complex adaptive system, the Nanoscale Informal Science Education Network (NISE Net). The results of the Complex Adaptive Systems as a Model for Network Evaluations (CASNET) project indicate that complex adaptive system concepts help to explain evaluation capacity building in a network. The NISE Network was found to be a complex learning system that was supportive of evaluation capacity building through feedback loops that provided for information sharing and interaction. Participants in the system had different levels of and sources of evaluation knowledge. To be successful at building capacity, the system needed to have a balance between both centralized and decentralized control, coherence, redundancy, and diversity. Embeddedness of individuals within the system also provided support and moved the capacity of the system forward. Finally, success depended on attention being paid to the control of resources. Implications of these findings are discussed. Copyright © 2018 Elsevier Ltd. All rights reserved.
41. ARAIII Prototype assembly and evaluation building ARA630. West end ...
41. ARA-III Prototype assembly and evaluation building ARA-630. West end and south side of building. Camera facing northeast. Ineel photo no. 3-22. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID
Strategic advantages of high-rise construction
NASA Astrophysics Data System (ADS)
Yaskova, Natalya
2018-03-01
Traditional methods to assess the competitiveness of different types of real estate in the context of huge changes of new technological way of life don't provide building solutions that would be correct from a strategic perspective. There are many challenges due to changes in the consumers' behavior in the housing area. A multiplicity of life models, a variety of opportunities and priorities, traditions and new trends in construction should be assessed in terms of prospective benefits in the environment of the emerging new world order. At the same time, the mane discourse of high-rise construction mainly relates to its design features, technical innovations, and architectural accents. We need to clarify the criteria for economic evaluation of high-rise construction in order to provide decisions with clear and quantifiable contexts. The suggested approach to assessing the strategic advantage of high-rise construction and the prospects for capitalization of high-rise buildings poses new challenges for the economy to identify adequate quantitative assessment methods of the high-rise buildings economic efficiency, taking into account all stages of their life cycle.
2015-01-01
Benchmarking data sets have become common in recent years for the purpose of virtual screening, though the main focus had been placed on the structure-based virtual screening (SBVS) approaches. Due to the lack of crystal structures, there is great need for unbiased benchmarking sets to evaluate various ligand-based virtual screening (LBVS) methods for important drug targets such as G protein-coupled receptors (GPCRs). To date these ready-to-apply data sets for LBVS are fairly limited, and the direct usage of benchmarking sets designed for SBVS could bring the biases to the evaluation of LBVS. Herein, we propose an unbiased method to build benchmarking sets for LBVS and validate it on a multitude of GPCRs targets. To be more specific, our methods can (1) ensure chemical diversity of ligands, (2) maintain the physicochemical similarity between ligands and decoys, (3) make the decoys dissimilar in chemical topology to all ligands to avoid false negatives, and (4) maximize spatial random distribution of ligands and decoys. We evaluated the quality of our Unbiased Ligand Set (ULS) and Unbiased Decoy Set (UDS) using three common LBVS approaches, with Leave-One-Out (LOO) Cross-Validation (CV) and a metric of average AUC of the ROC curves. Our method has greatly reduced the “artificial enrichment” and “analogue bias” of a published GPCRs benchmarking set, i.e., GPCR Ligand Library (GLL)/GPCR Decoy Database (GDD). In addition, we addressed an important issue about the ratio of decoys per ligand and found that for a range of 30 to 100 it does not affect the quality of the benchmarking set, so we kept the original ratio of 39 from the GLL/GDD. PMID:24749745
Xia, Jie; Jin, Hongwei; Liu, Zhenming; Zhang, Liangren; Wang, Xiang Simon
2014-05-27
Benchmarking data sets have become common in recent years for the purpose of virtual screening, though the main focus had been placed on the structure-based virtual screening (SBVS) approaches. Due to the lack of crystal structures, there is great need for unbiased benchmarking sets to evaluate various ligand-based virtual screening (LBVS) methods for important drug targets such as G protein-coupled receptors (GPCRs). To date these ready-to-apply data sets for LBVS are fairly limited, and the direct usage of benchmarking sets designed for SBVS could bring the biases to the evaluation of LBVS. Herein, we propose an unbiased method to build benchmarking sets for LBVS and validate it on a multitude of GPCRs targets. To be more specific, our methods can (1) ensure chemical diversity of ligands, (2) maintain the physicochemical similarity between ligands and decoys, (3) make the decoys dissimilar in chemical topology to all ligands to avoid false negatives, and (4) maximize spatial random distribution of ligands and decoys. We evaluated the quality of our Unbiased Ligand Set (ULS) and Unbiased Decoy Set (UDS) using three common LBVS approaches, with Leave-One-Out (LOO) Cross-Validation (CV) and a metric of average AUC of the ROC curves. Our method has greatly reduced the "artificial enrichment" and "analogue bias" of a published GPCRs benchmarking set, i.e., GPCR Ligand Library (GLL)/GPCR Decoy Database (GDD). In addition, we addressed an important issue about the ratio of decoys per ligand and found that for a range of 30 to 100 it does not affect the quality of the benchmarking set, so we kept the original ratio of 39 from the GLL/GDD.
Kim, Augustine Yongwhi; Choi, Hoduk
2018-01-01
The purpose of this paper is to evaluate food taste, smell, and characteristics from consumers' online reviews. Several studies in food sensory evaluation have been presented for consumer acceptance. However, these studies need taste descriptive word lexicon, and they are not suitable for analyzing large number of evaluators to predict consumer acceptance. In this paper, an automated text analysis method for food evaluation is presented to analyze and compare recently introduced two jjampong ramen types (mixed seafood noodles). To avoid building a sensory word lexicon, consumers' reviews are collected from SNS. Then, by training word embedding model with acquired reviews, words in the large amount of review text are converted into vectors. Based on these words represented as vectors, inference is performed to evaluate taste and smell of two jjampong ramen types. Finally, the reliability and merits of the proposed food evaluation method are confirmed by a comparison with the results from an actual consumer preference taste evaluation. PMID:29606960
Kim, Augustine Yongwhi; Ha, Jin Gwan; Choi, Hoduk; Moon, Hyeonjoon
2018-01-01
The purpose of this paper is to evaluate food taste, smell, and characteristics from consumers' online reviews. Several studies in food sensory evaluation have been presented for consumer acceptance. However, these studies need taste descriptive word lexicon, and they are not suitable for analyzing large number of evaluators to predict consumer acceptance. In this paper, an automated text analysis method for food evaluation is presented to analyze and compare recently introduced two jjampong ramen types (mixed seafood noodles). To avoid building a sensory word lexicon, consumers' reviews are collected from SNS. Then, by training word embedding model with acquired reviews, words in the large amount of review text are converted into vectors. Based on these words represented as vectors, inference is performed to evaluate taste and smell of two jjampong ramen types. Finally, the reliability and merits of the proposed food evaluation method are confirmed by a comparison with the results from an actual consumer preference taste evaluation.
Development of air conditioning technologies to reduce CO2 emissions in the commercial sector
Yoshida, Yukiko
2006-01-01
Background Architectural methods that take into account global environmental conservation generally concentrate on mitigating the heat load of buildings. Here, we evaluate the reduction of carbon dioxide (CO2) emissions that can be achieved by improving heating, ventilating, and air conditioning (HVAC) technologies. Results The Climate Change Research Hall (CCRH) of the National Institute for Environmental Studies (NIES) is used as a case study. CCRH was built in line with the "Green Government Buildings" program of the Government Buildings Department at the Ministry of Land, Infrastructure and Transport in Japan. We have assessed the technology used in this building, and found that there is a possibility to reduce energy consumption in the HVAC system by 30%. Conclusion Saving energy reduces CO2 emissions in the commercial sector, although emission factors depend on the country or region. Consequently, energy savings potential may serve as a criterion in selecting HVAC technologies with respect to emission reduction targets. PMID:17062161
Modeling injury rates as a function of industrialized versus on-site construction techniques.
Rubio-Romero, J C; Suárez-Cebador, M; Abad, Jesús
2014-05-01
It is often predicted that the industrialization of building activities will lead to a reduction of accident rates in the construction sector, particularly as a result of switching activities from building sites to factories. However, to date no scientific research has provided objective quantitative results to back up this claim. The aim of this paper is to evaluate how industrialization affects the accident rate in different industrialized building systems in Spain. Our results revealed that the industrialized steel modular system presents the lowest accident rate, while the highest accident rate was recorded in the construction method with cast-in-place concrete. The lightweight construction system also presents a high accident rate. Accordingly, industrialized building systems cannot claim to be safer than traditional ones. The different types of "on-site work" seem to be the main variable which would explain the accident rates recorded in industrialized construction systems. Copyright © 2014 Elsevier Ltd. All rights reserved.
Modelling Complex Fenestration Systems using physical and virtual models
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thanachareonkit, Anothai; Scartezzini, Jean-Louis
2010-04-15
Physical or virtual models are commonly used to visualize the conceptual ideas of architects, lighting designers and researchers; they are also employed to assess the daylighting performance of buildings, particularly in cases where Complex Fenestration Systems (CFS) are considered. Recent studies have however revealed a general tendency of physical models to over-estimate this performance, compared to those of real buildings; these discrepancies can be attributed to several reasons. In order to identify the main error sources, a series of comparisons in-between a real building (a single office room within a test module) and the corresponding physical and virtual models wasmore » undertaken. The physical model was placed in outdoor conditions, which were strictly identical to those of the real building, as well as underneath a scanning sky simulator. The virtual model simulations were carried out by way of the Radiance program using the GenSky function; an alternative evaluation method, named Partial Daylight Factor method (PDF method), was also employed with the physical model together with sky luminance distributions acquired by a digital sky scanner during the monitoring of the real building. The overall daylighting performance of physical and virtual models were assessed and compared. The causes of discrepancies between the daylighting performance of the real building and the models were analysed. The main identified sources of errors are the reproduction of building details, the CFS modelling and the mocking-up of the geometrical and photometrical properties. To study the impact of these errors on daylighting performance assessment, computer simulation models created using the Radiance program were also used to carry out a sensitivity analysis of modelling errors. The study of the models showed that large discrepancies can occur in daylighting performance assessment. In case of improper mocking-up of the glazing for instance, relative divergences of 25-40% can be found in different room locations, suggesting that more light is entering than actually monitored in the real building. All these discrepancies can however be reduced by making an effort to carefully mock up the geometry and photometry of the real building. A synthesis is presented in this article which can be used as guidelines for daylighting designers to avoid or estimate errors during CFS daylighting performance assessment. (author)« less
Stals, M; Verhoeven, S; Bruggeman, M; Pellens, V; Schroeyers, W; Schreurs, S
2014-01-01
The Euratom BSS requires that in the near future (2015) the building materials for application in dwellings or buildings such as offices or workshops are screened for NORM nuclides. The screening tool is the activity concentration index (ACI). Therefore it is expected that a large number of building materials will be screened for NORM and thus require ACI determination. Nowadays, the proposed standard for determination of building material ACI is a laboratory analyses technique with high purity germanium spectrometry and 21 days equilibrium delay. In this paper, the B-NORM method for determination of building material ACI is assessed as a faster method that can be performed on-site, alternative to the aforementioned standard method. The B-NORM method utilizes a LaBr3(Ce) scintillation probe to obtain the spectral data. Commercially available software was applied to comprehensively take into account the factors determining the counting efficiency. The ACI was determined by interpreting the gamma spectrum from (226)Ra and its progeny; (232)Th progeny and (40)K. In order to assess the accuracy of the B-NORM method, a large selection of samples was analyzed by a certified laboratory and the results were compared with the B-NORM results. The results obtained with the B-NORM method were in good correlation with the results obtained by the certified laboratory, indicating that the B-NORM method is an appropriate screening method to assess building material ACI. The B-NORM method was applied to analyze more than 120 building materials on the Belgian market. No building materials that exceed the proposed reference level of 1 mSv/year were encountered. Copyright © 2013 Elsevier Ltd. All rights reserved.
Review of Methods for Buildings Energy Performance Modelling
NASA Astrophysics Data System (ADS)
Krstić, Hrvoje; Teni, Mihaela
2017-10-01
Research presented in this paper gives a brief review of methods used for buildings energy performance modelling. This paper gives also a comprehensive review of the advantages and disadvantages of available methods as well as the input parameters used for modelling buildings energy performance. European Directive EPBD obliges the implementation of energy certification procedure which gives an insight on buildings energy performance via exiting energy certificate databases. Some of the methods for buildings energy performance modelling mentioned in this paper are developed by employing data sets of buildings which have already undergone an energy certification procedure. Such database is used in this paper where the majority of buildings in the database have already gone under some form of partial retrofitting - replacement of windows or installation of thermal insulation but still have poor energy performance. The case study presented in this paper utilizes energy certificates database obtained from residential units in Croatia (over 400 buildings) in order to determine the dependence between buildings energy performance and variables from database by using statistical dependencies tests. Building energy performance in database is presented with building energy efficiency rate (from A+ to G) which is based on specific annual energy needs for heating for referential climatic data [kWh/(m2a)]. Independent variables in database are surfaces and volume of the conditioned part of the building, building shape factor, energy used for heating, CO2 emission, building age and year of reconstruction. Research results presented in this paper give an insight in possibilities of methods used for buildings energy performance modelling. Further on it gives an analysis of dependencies between buildings energy performance as a dependent variable and independent variables from the database. Presented results could be used for development of new building energy performance predictive model.
Some Underexamined Aspects of Evaluation Capacity Building
ERIC Educational Resources Information Center
Leviton, Laura C.
2014-01-01
Evaluation capacity building (ECB) has progressed as a concept since it was the conference theme of the American Evaluation Association in the year 2000. This commentary poses some questions about underexamined issues in ECB about organizations, evaluators, and funders.
Fire safety evaluation system for NASA office/laboratory buildings
NASA Astrophysics Data System (ADS)
Nelson, H. E.
1986-11-01
A fire safety evaluation system for office/laboratory buildings is developed. The system is a life safety grading system. The system scores building construction, hazardous areas, vertical openings, sprinklers, detectors, alarms, interior finish, smoke control, exit systems, compartmentation, and emergency preparedness.
Structural evaluation of the 2736Z Building for seismic loads
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giller, R.A.
The 2736Z building structure is evaluated for high-hazard loads. The 2736Z building is analyzed herein for normal and seismic loads and is found to successfully meet the guidelines of UCRL-15910 along with the related codes requirements.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stewart, James
Strategic energy management (SEM) focuses on achieving energy-efficiency improvements through systematic and planned changes in facility operations, maintenance, and behaviors (OM&B) and capital equipment upgrades in large energy-using facilities, including industrial buildings, commercial buildings, and multi-facility organizations such as campuses or communities. Facilities can institute a spectrum of SEM actions, ranging from a simple process for regularly identifying energy-savings actions, to establishing a formal, third-party recognized or certified SEM framework for continuous improvement of energy performance. In general, SEM programs that would be considered part of a utility program will contain a set of energy-reducing goals, principles, and practices emphasizingmore » continuous improvements in energy performance or savings through energy management and an energy management system (EnMS).« less
Use of an expert system data analysis manager for space shuttle main engine test evaluation
NASA Technical Reports Server (NTRS)
Abernethy, Ken
1988-01-01
The ability to articulate, collect, and automate the application of the expertise needed for the analysis of space shuttle main engine (SSME) test data would be of great benefit to NASA liquid rocket engine experts. This paper describes a project whose goal is to build a rule-based expert system which incorporates such expertise. Experiential expertise, collected directly from the experts currently involved in SSME data analysis, is used to build a rule base to identify engine anomalies similar to those analyzed previously. Additionally, an alternate method of expertise capture is being explored. This method would generate rules inductively based on calculations made using a theoretical model of the SSME's operation. The latter rules would be capable of diagnosing anomalies which may not have appeared before, but whose effects can be predicted by the theoretical model.
Vocal cord dysfunction related to water-damaged buildings.
Cummings, Kristin J; Fink, Jordan N; Vasudev, Monica; Piacitelli, Chris; Kreiss, Kathleen
2013-01-01
Vocal cord dysfunction (VCD) is the intermittent paradoxical adduction of the vocal cords during respiration, resulting in variable upper airway obstruction. Exposure to damp indoor environments is associated with adverse respiratory health outcomes, including asthma, but its role in the development of VCD is not well described. We describe the spectrum of respiratory illness in occupants of 2 water-damaged office buildings. The National Institute for Occupational Safety and Health conducted a health hazard evaluation that included interviews with managers, a maintenance officer, a remediation specialist who had evaluated the 2 buildings, employees, and consulting physicians. In addition, medical records and reports of building evaluations were reviewed. Diagnostic evaluations for VCD had been conducted at the Asthma and Allergy Center of the Medical College of Wisconsin. Two cases of VCD were temporally related to occupancy of water-damaged buildings. The patients experienced cough, chest tightness, dyspnea, wheezing, and hoarseness when in the buildings. Spirometry was normal. Methacholine challenge did not show bronchial hyperreactivity but did elicit symptoms of VCD and inspiratory flow-volume loop truncation. Direct laryngoscopy revealed vocal cord adduction during inspiration. Coworkers developed upper and lower respiratory symptoms; their diagnoses included sinusitis and asthma, consistent with recognized effects of exposure to indoor dampness. Building evaluations provided evidence of water damage and mold growth. VCD can occur with exposure to water-damaged buildings and should be considered in exposed patients with asthma-like symptoms. Published by Elsevier Inc.
Assessment of village health worker training program in Tuguegarao, Philippine.
Kim, Jung Min; Koh, Kwang Wook; Oak, Chul Ho; Jung, Woo Hyuk; Kim, Sung Hyun; Park, Dae Hee
2009-11-01
This study was performed to evaluate the effectiveness of 'village health worker training program' which aimed to build community participatory health promotion capacity of community leaders in villages of low developed country and to develop methods for further development of the program. The intervention group were 134 community leaders from 25 barangays (village). Control group were 149 form 4 barangays. Intervention group participated 3-day training program. Questionnaire was developed based on 'Health Promotion Capacity Checklist' which assessed capacity in 4 feathers; 'knowledge', 'skill', 'commitment', and 'resource'. Each feather was assessed in 4 point rating scale. Capacity scores between intervention group and control group were examined to identify changes between the pre- and post-intervention periods. A qualitative evaluation of the program was conducted to assess the appropriateness of the program. The program was conducted in Tuguegarao city, Philippine in January, 2009. The result showed significant increases in the total health promotion capacity and each feather of health promotion capacities between pre and post assessment of intervention group. But there was no significant change in that of control group. Participants marked high level of satisfaction for preparedness, selection of main subjects and education method. Qualitative evaluation revealed that training program facilitated community participatory health promotion capacity of participants. This study suggested that the Village health worker training program is effective for building health promotion capacity of community leaders and it can be a main method for helping low developed countries with further development.
A logic-based method to build signaling networks and propose experimental plans.
Rougny, Adrien; Gloaguen, Pauline; Langonné, Nathalie; Reiter, Eric; Crépieux, Pascale; Poupon, Anne; Froidevaux, Christine
2018-05-18
With the dramatic increase of the diversity and the sheer quantity of biological data generated, the construction of comprehensive signaling networks that include precise mechanisms cannot be carried out manually anymore. In this context, we propose a logic-based method that allows building large signaling networks automatically. Our method is based on a set of expert rules that make explicit the reasoning made by biologists when interpreting experimental results coming from a wide variety of experiment types. These rules allow formulating all the conclusions that can be inferred from a set of experimental results, and thus building all the possible networks that explain these results. Moreover, given an hypothesis, our system proposes experimental plans to carry out in order to validate or invalidate it. To evaluate the performance of our method, we applied our framework to the reconstruction of the FSHR-induced and the EGFR-induced signaling networks. The FSHR is known to induce the transactivation of the EGFR, but very little is known on the resulting FSH- and EGF-dependent network. We built a single network using data underlying both networks. This leads to a new hypothesis on the activation of MEK by p38MAPK, which we validate experimentally. These preliminary results represent a first step in the demonstration of a cross-talk between these two major MAP kinases pathways.
Use Of Infrared Thermography For The Identification Of Design And Construction Faults In Buildings
NASA Astrophysics Data System (ADS)
Seeber, Stephen A.
1984-03-01
Many design and construction details can affect building energy consumption in unex-pected ways. Further, design and construction errors can increase building energy consumption, result in discomfort to building occupants and cause structural damage to the building. Infrared inspections can easily evaluate the energy efficiency of various aspects of a building's design and identify flaws that might otherwise be detected as a result of occupants' complaints or damage to the building's mechanical or structural systems. Infrared thermography can be used by the architect to evaluate his designs and by the contractor to control the quality of construction. This paper discusses a number of issues that can help determine the effectiveness of infrared building surveys. Following this, three case stud-ies will be presented to illustrate design flaws that were detected through infrared build-ing surveys.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neymark, J.; Kennedy, M.; Judkoff, R.
This report documents a set of diagnostic analytical verification cases for testing the ability of whole building simulation software to model the air distribution side of typical heating, ventilating and air conditioning (HVAC) equipment. These cases complement the unitary equipment cases included in American National Standards Institute (ANSI)/American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs, which test the ability to model the heat-transfer fluid side of HVAC equipment.
Zimmermann, Johannes; Wright, Aidan G C
2017-01-01
The interpersonal circumplex is a well-established structural model that organizes interpersonal functioning within the two-dimensional space marked by dominance and affiliation. The structural summary method (SSM) was developed to evaluate the interpersonal nature of other constructs and measures outside the interpersonal circumplex. To date, this method has been primarily descriptive, providing no way to draw inferences when comparing SSM parameters across constructs or groups. We describe a newly developed resampling-based method for deriving confidence intervals, which allows for SSM parameter comparisons. In a series of five studies, we evaluated the accuracy of the approach across a wide range of possible sample sizes and parameter values, and demonstrated its utility for posing theoretical questions on the interpersonal nature of relevant constructs (e.g., personality disorders) using real-world data. As a result, the SSM is strengthened for its intended purpose of construct evaluation and theory building. © The Author(s) 2015.
Dettori, Maria Antonietta; Fabbri, Davide; Pisano, Marina; Rozzo, Carla; Palmieri, Giuseppe; Dess, Alessandro; Dallocchio, Roberto; Delogu, Giovanna
2015-02-01
A small collection of eugenol- and curcumin-analog hydroxylated biphenyls was prepared by straightforward methods starting from natural 4-substituted-2-methoxyphenols and their antitumoral activity was evaluated in vitro . Two curcumin-biphenyl derivatives showed interesting growth inhibitory activities on different malignant melanoma cell lines with IC 50 ranging from 13 to 1 µM. Preliminary molecular modeling studies were carried out to evaluate conformations and dihedral angles suitable for antiproliferative activity in hydroxylated biphenyls bearing a side aliphatic chain.
[Integral quantitative evaluation of working conditions in the construction industry].
Guseĭnov, A A
1993-01-01
Present method evaluating the quality of environment (using MAC and MAL) does not enable to assess completely and objectively the work conditions of building industry due to multiple confounding elements. A solution to this complicated problem including the analysis of various correlating elements of the system "human--work conditions--environment" may be encouraged by social norm of morbidity, which is independent on industrial and natural environment. The complete integral assessment enables to see the whole situation and reveal the points at risk.
Women and the Crossroads of Science: Thoughts on Policy, Research, and Evaluation
NASA Astrophysics Data System (ADS)
Dietz, James S.; Anderson, Bernice; Katzenmeyer, Conrad
In this essay, the authors examine the crosscutting themes of this special issue as they pertain to policy, research, and evaluation of women and science. Past and current research, theory, frameworks, and programs are discussed in the context of challenges and innovations for methods and policy. The authors assert that the crossroads for gender equity studies lies at the intersection of science and society and argue for the need to build a base of cumulative knowledge for policy and practice.
Rapid Radiochemical Method for Radium-226 in Building ...
Technical Fact Sheet Analysis Purpose: Qualitative analysis Technique: Alpha spectrometry Method Developed for: Radium-226 in building materials Method Selected for: SAM lists this method for qualitative analysis of radium-226 in concrete or brick building materials Summary of subject analytical method which will be posted to the SAM website to allow access to the method.
Rapid Radiochemical Method for Americium-241 in Building ...
Technical Fact Sheet Analysis Purpose: Qualitative analysis Technique: Alpha spectrometry Method Developed for: Americium-241 in building materials Method Selected for: SAM lists this method for qualitative analysis of americium-241 in concrete or brick building materials. Summary of subject analytical method which will be posted to the SAM website to allow access to the method.
NASA Astrophysics Data System (ADS)
Güney, D.; Aydin, E.; Öztürk, B.
2015-07-01
On March 8th, 2010 Karakocan-Elazig earthquake of magnitude 6.0 occurred at a region where masonry and adobe construction is very common. Karakocan-Elazig is located in a high seismicity region on Eastern Anatolian Fault System (EAFS). Due to the earthquake, 42 people were killed and 14’113 buildings were damaged. Another city, Van located at South east of Turkey is hit by earthquakes with M = 7.2 occurred on October 23rd, 2011 at 13:41 (local time), whose epicenter was about 16 km north of Van (Tabanli village) and M = 5.6 on November 9th, 2011 with an epicenter near the town of Edremit, south of Van and caused the loss of life and heavy damages. Both earthquakes killed 644 people and 2608 people were injured. Approximately 10’000 buildings were seriously damaged. There are many traditional types of structures existing in the region hit by earthquakes (both Van and Elazig). These buildings were built as adobe, unreinforced masonry or mixed type. These types of buildings are very common in rural areas (especially south and east) of Turkey because of easy workmanship and cheap construction cost. Many of those traditional type structures experienced serious damages. The use of masonry is very common in some of the world's most hazard-prone regions, such as in Latin America, Africa, the Indian subcontinent and other parts of Asia, the Middle East, and southern Europe. Based on damage and failure mechanism of those buildings, the parameters affecting the seismic performance of those traditional buildings are analyzed in this paper. The foundation type, soil conditions, production method of the masonry blocks, construction method, the geometry of the masonry walls, workmanship quality, existence of wooden beams, type of roof, mortar between adobe blocks are studied in order to understand the reason of damage for these types of buildings.
Building Scientific Confidence in the Development and ...
Building Scientific Confidence in the Development and Evaluation of Read-Across Using Tox21 Approaches Slide presentation at GlobalChem conference and workshop in Washington, DC on Case Study on Building Scientific Confidence in the Development and Evaluation of Read-Across Using Tox21 Approaches
ERIC Educational Resources Information Center
Dempsey, Owen P.; Lucas, Beverley J.
2006-01-01
This article explores a qualitative evaluation of student and tutor perceptions of the educational aims, methods and impact of undertaking a new medical humanities student selected module (SSM) within one medical school in the United Kingdom. The findings of the study build on previous work within this subject area and provide insight of learning…
ERIC Educational Resources Information Center
Beal, Carole R.; Rosenblum, L. Penny
2015-01-01
Introduction: The present study evaluated the feasibility of using an iPad application or "app" for algebra-readiness mathematics, with accompanying braille materials and accessible graphics, when used in authentic educational settings. Methods: Twenty-nine students with visual impairments in grades 4-11 used the materials under the…
Based on the results of this project, we will be able to make recommendations about 1) the level of treatment captured rainwater from green buildings requires and 2) how metal ions and chitosan or chitosan nanoparticles can be used to achieve the necessary level of treatment. ...
How to Deal with Emotional Abuse and Neglect--Further Development of a Conceptual Framework (FRAMEA)
ERIC Educational Resources Information Center
Glaser, Danya
2011-01-01
Objective: To develop further the understanding of emotional abuse and neglect. Methods: Building on previous work, this paper describes the further development of a conceptual framework for the recognition and management of emotional abuse and neglect. Training in this framework is currently being evaluated. The paper also briefly reviews more…
Model of Values-Based Management Process in Schools: A Mixed Design Study
ERIC Educational Resources Information Center
Dogan, Soner
2016-01-01
The aim of this paper is to evaluate the school administrators' values-based management behaviours according to the teachers' perceptions and opinions and, accordingly, to build a model of values-based management process in schools. The study was conducted using explanatory design which is inclusive of both quantitative and qualitative methods.…
NASA Technical Reports Server (NTRS)
Joyner, James J., Sr.
2014-01-01
Develop Survivability vs Time Model as a decision-evaluation tool to assess various emergency egress methods used at Launch Complex 39B (LC 39B) and in the Vehicle Assembly Building (VAB) on NASAs Kennedy Space Center. For each hazard scenario, develop probability distributions to address statistical uncertainty resulting in survivability plots over time and composite survivability plots encompassing multiple hazard scenarios.
2007-01-05
positive / false negatives. The quantitative on-site methods were evaluated using linear regression analysis and relative percent difference (RPD) comparison...Conclusion ...............................................................................................3-9 3.2 Quantitative Analysis Using CRREL...3-37 3.3 Quantitative Analysis for NG by GC/TID.........................................................3-38 3.3.1 Introduction
School Retrofit Design Analysis System. A Microcomputer Model for School Energy Use.
ERIC Educational Resources Information Center
Canipe, Stephen Lee
The School Retrofit Design Analysis System (SRDAS) developed in this study provides a non-technical method for the school administrator to use in evaluating alternative energy saving retrofit and new construction design possibilities. By providing a high degree of flexibility, SRDAS is applicable to a wide range of school building and retrofit…
Nakaima, April; Sridharan, Sanjeev
2017-05-08
This paper discusses what was learned about evaluation capacity building with community organizations who deliver services to individuals with neurological disorders. Evaluation specialists engaged by the Ontario Brain Institute Evaluation Support Program were paired with community organizations, such as Dancing With Parkinson's. Some of the learning included: relationship building is key for this model of capacity building; community organizations often have had negative experiences with evaluation and the idea that evaluations can be friendly tools in implementing meaningful programs is one key mechanism by which such an initiative can work; community organizations often need evaluation most to be able to demonstrate their value; a strength of this initiative was that the focus was not just on creating products but mostly on developing a learning process in which capacities would remain; evaluation tools and skills that organizations found useful were developing a theory of change and the concept of heterogeneous mechanisms (informed by a realist evaluation lens). Copyright © 2017. Published by Elsevier Ltd.
Nickel, Daniela Alba; Calvo, Maria Cristina Marino; Natal, Sonia; Freitas, Sérgio Fernando Torres de; Hartz, Zulmira Maria de Araújo
2014-04-01
This article analyzes evaluation capacity-building based on the case study of a State Health Secretariat participating in the Project to Strengthen the Technical Capacity of State Health Secretariats in Monitoring and Evaluating Primary Healthcare. The case study adopted a mixed design with information from documents, semi-structured interviews, and evaluation of primary care by the State Health Secretariat in 2008-2011. Process analysis was used to identify the logical events that contributed to evaluation capacity-building, with two categories: evaluation capacity-building events and events for building organizational structure. The logical chain of events was formed by negotiation and agreement on the decision-making levels for the continuity of evaluation, data collection and analysis by the State Health Secretariat, a change in key indicators, restructuring of the evaluation matrix, and communication of the results to the municipalities. The three-way analysis showed that the aim of developing evaluation capacity was achieved.
Organizational Capacity to Do and Use Evaluation: Results of a Pan-Canadian Survey of Evaluators
ERIC Educational Resources Information Center
Cousins, J. Bradley; Elliott, Catherine; Amo, Courtney; Bourgeois, Isabelle; Chouinard, Jill; Goh, Swee C.; Lahey, Robert
2008-01-01
Despite increasing interest in the integration of evaluative inquiry into organizational functions and culture, the availability of empirical research addressing organizational capacity building to do and use evaluation is limited. This exploratory descriptive survey of internal evaluators in Canada asked about evaluation capacity building in the…
Maximize Energy Efficiency in Buildings | Climate Neutral Research Campuses
Buildings on a research campus, especially laboratory buildings, often represent the most cost-effective plans, campuses can evaluate the following: Energy Management Building Management New Buildings Design
NASA Astrophysics Data System (ADS)
Wang, Jinxia; Dou, Aixia; Wang, Xiaoqing; Huang, Shusong; Yuan, Xiaoxiang
2016-11-01
Compared to remote sensing image, post-earthquake airborne Light Detection And Ranging (LiDAR) point cloud data contains a high-precision three-dimensional information on earthquake disaster which can improve the accuracy of the identification of destroy buildings. However after the earthquake, the damaged buildings showed so many different characteristics that we can't distinguish currently between trees and damaged buildings points by the most commonly used method of pre-processing. In this study, we analyse the number of returns for given pulse of trees and damaged buildings point cloud and explore methods to distinguish currently between trees and damaged buildings points. We propose a new method by searching for a certain number of neighbourhood space and calculate the ratio(R) of points whose number of returns for given pulse greater than 1 of the neighbourhood points to separate trees from buildings. In this study, we select some point clouds of typical undamaged building, collapsed building and tree as samples from airborne LiDAR point cloud data which got after 2010 earthquake in Haiti MW7.0 by the way of human-computer interaction. Testing to get the Rvalue to distinguish between trees and buildings and apply the R-value to test testing areas. The experiment results show that the proposed method in this study can distinguish between building (undamaged and damaged building) points and tree points effectively but be limited in area where buildings various, damaged complex and trees dense, so this method will be improved necessarily.
Developing Evaluation Capacity through Process Use
ERIC Educational Resources Information Center
King, Jean A.
2007-01-01
This article discusses how to make process use an independent variable in evaluation practice: the purposeful means of building an organization's capacity to conduct and use evaluations in the long run. The goal of evaluation capacity building (ECB) is to strengthen and sustain effective program evaluation practices through a number of activities:…
[Development of green hospitals home and abroad].
Yang, Yiju; Zeng, Na; Shen, Minxue; Sun, Zhenqiu
2013-09-01
Green hospital construction is a new challenge for medical industry after global sustainable development strategy was put forward. The core connotation of green hospital includes green building, green healthcare, patient safety, and doctor-patient harmony. Many countries have established green building evaluation system to deal with energy crisis. Leadership in Energy and Environmental Design (LEED), Green Guide for Health Care (GGHC) in the U.S., and Evaluation System for Green Hospital Building (CSUS/GBC 2-2011) in China have guiding significance for the development of green hospitals in China. The evaluation system of green hospitals home and abroad still focuses on green building, and establishment of suitable synthesis evaluation system of green hospitals in China needs further research.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Levy, E.; Mullens, M.; Rath, P.
The Advanced Envelope Research effort will provide factory homebuilders with high performance, cost-effective envelope designs that can be effectively integrated into the plant production process while meeting the thermal requirements of the 2012 IECC standards. Given the affordable nature of manufactured homes, impact on first cost is a major consideration in developing new envelope technologies. This work is part of a multi-phase effort. Phase 1 identified seven envelope technologies and provided a preliminary assessment of three methods for building high performance walls. Phase 2 focused on developing viable product designs, manufacturing strategies, addressing code and structural issues, and cost analysismore » of the three selected options. An industry advisory committee helped narrow the research focus to perfecting a stud wall design with exterior continuous insulation (CI). Phase 3, completed in two stages, continued the design development effort, exploring and evaluating a range or methods for applying CI to factory built homes. The scope also included material selection, manufacturing and cost analysis, and prototyping and testing. During this phase, a home was built with CI, evaluated, and placed in service. The experience of building a mock up wall section with CI and then constructing on line a prototype home resolved important concerns about how to integrate the material into the production process. First steps were taken toward finding least expensive approaches for incorporating CI in standard factory building practices and a preliminary assessment suggested that even at this early stage the technology is attractive when viewed from a life cycle cost perspective.« less
Building Condition and Suitability Evaluation Manual.
ERIC Educational Resources Information Center
MGT of America, Inc., Tallahassee, FL.
This educational facility evaluation manual contains the overall building condition rating form and the supporting check sheets which have been field tested in several states and, where appropriate, modified for use in the Idaho School Facilities Needs Assessment. The exterior building condition form examines the foundation, structure, walls,…
Evaluating the Health of Your House.
ERIC Educational Resources Information Center
Berthold-Bond, Annie; Dadd, Debra Lynn
1993-01-01
Presents a framework from which individuals can evaluate the health environment in their homes. Questions are arranged to examine the general location of the house, the house's immediate surroundings and building shell, and the finishings. Provides a resource directory for air filters, building consultants, and building supplies. (MDH)
Evaluation of the Watertown Arsenal Building #311 as an ILS Model Range
DOT National Transportation Integrated Search
1973-12-01
The Watertown Arsenal Building No. 311 was evaluated for use as an indoor Instrument Landing System (ILS) model range using upward frequency scaling of 100 to 1. To model the effects of small buildings and aircraft in the vicinity of an airport ILS, ...
Dewey, Charlene M; Turner, Teri L; Perkowski, Linda; Bailey, Jean; Gruppen, Larry D; Riddle, Janet; Singhal, Geeta; Mullan, Patricia; Poznanski, Ann; Pillow, Tyson; Robins, Lynne S; Rougas, Steven C; Horn, Leora; Ghulyan, Marine V; Simpson, Deborah
2016-01-01
Medical education fellowship programs (MEFPs) are a form of faculty development contributing to an organization's educational mission and participants' career development. Building an MEFP requires a systematic design, implementation, and evaluation approach which aligns institutional and individual faculty goals. Implementing an MEFP requires a team of committed individuals who provide expertise, guidance, and mentoring. Qualified MEFP directors should utilize instructional methods that promote individual and institutional short and long term growth. Directors must balance the use of traditional design, implementation, and evaluation methodologies with advancing trends that may support or threaten the acceptability and sustainability of the program. Drawing on the expertise of 28 MEFP directors, we provide twelve tips as a guide to those implementing, sustaining, and/or growing a successful MEFP whose value is demonstrated by its impacts on participants, learners, patients, teaching faculty, institutions, the greater medical education community, and the population's health.
NASA Astrophysics Data System (ADS)
Orłowski, Z.; Radziejowska, A.; Orłowski, M.
2017-10-01
In the article the authors consider one of the basic aspects of sustainable construction regarding the social utility of a building. According to standard PN-EN 16309+A1:2014-12 during evaluating the social aspect should be assessed six categories: accessibility, adaptability, comfort and health, neighborhood, maintenance, safety and security. The authors present the evaluation criteria witch should be taken into account in the assessment of the second of them. Adaptability has been divided into three categories: The buidling’s ability to accomodate the change of user requirements, The buidling’s ability to accomodate technical changes, The buidling’s ability to accomodate the change of use. Each subcategory has been further elaborated by the criteria for which authors present proposal for the scale of assessments. The authors present a part of a work to construct a method for assessing the social characteristics of the residential buildings.
Effective Energy Simulation and Optimal Design of Side-lit Buildings with Venetian Blinds
NASA Astrophysics Data System (ADS)
Cheng, Tian
Venetian blinds are popularly used in buildings to control the amount of incoming daylight for improving visual comfort and reducing heat gains in air-conditioning systems. Studies have shown that the proper design and operation of window systems could result in significant energy savings in both lighting and cooling. However, there is no convenient computer tool that allows effective and efficient optimization of the envelope of side-lit buildings with blinds now. Three computer tools, Adeline, DOE2 and EnergyPlus widely used for the above-mentioned purpose have been experimentally examined in this study. Results indicate that the two former tools give unacceptable accuracy due to unrealistic assumptions adopted while the last one may generate large errors in certain conditions. Moreover, current computer tools have to conduct hourly energy simulations, which are not necessary for life-cycle energy analysis and optimal design, to provide annual cooling loads. This is not computationally efficient, particularly not suitable for optimal designing a building at initial stage because the impacts of many design variations and optional features have to be evaluated. A methodology is therefore developed for efficient and effective thermal and daylighting simulations and optimal design of buildings with blinds. Based on geometric optics and radiosity method, a mathematical model is developed to reasonably simulate the daylighting behaviors of venetian blinds. Indoor illuminance at any reference point can be directly and efficiently computed. They have been validated with both experiments and simulations with Radiance. Validation results show that indoor illuminances computed by the new models agree well with the measured data, and the accuracy provided by them is equivalent to that of Radiance. The computational efficiency of the new models is much higher than that of Radiance as well as EnergyPlus. Two new methods are developed for the thermal simulation of buildings. A fast Fourier transform (FFT) method is presented to avoid the root-searching process in the inverse Laplace transform of multilayered walls. Generalized explicit FFT formulae for calculating the discrete Fourier transform (DFT) are developed for the first time. They can largely facilitate the implementation of FFT. The new method also provides a basis for generating the symbolic response factors. Validation simulations show that it can generate the response factors as accurate as the analytical solutions. The second method is for direct estimation of annual or seasonal cooling loads without the need for tedious hourly energy simulations. It is validated by hourly simulation results with DOE2. Then symbolic long-term cooling load can be created by combining the two methods with thermal network analysis. The symbolic long-term cooling load can keep the design parameters of interest as symbols, which is particularly useful for the optimal design and sensitivity analysis. The methodology is applied to an office building in Hong Kong for the optimal design of building envelope. Design variables such as window-to-wall ratio, building orientation, and glazing optical and thermal properties are included in the study. Results show that the selected design values could significantly impact the energy performance of windows, and the optimal design of side-lit buildings could greatly enhance energy savings. The application example also demonstrates that the developed methodology significantly facilitates the optimal building design and sensitivity analysis, and leads to high computational efficiency.
Ju, Hyunjin; Lee, Deuck Hang; Cho, Hae-Chang; Kim, Kang Su; Yoon, Seyoon; Seo, Soo-Yeon
2014-01-01
In this study, hydrophilic chemical grout using silanol (HCGS) was adopted to overcome the performance limitations of epoxy materials used for strengthening existing buildings and civil engineering structures. The enhanced material performances of HCGS were introduced, and applied to the section enlargement method, which is one of the typical structural strengthening methods used in practice. To evaluate the excellent structural strengthening performance of the HCGS, structural tests were conducted on reinforced concrete beams, and analyses on the flexural behaviors of test specimens were performed by modified partial interaction theory (PIT). In particular, to improve the constructability of the section enlargement method, an advanced strengthening method was proposed, in which the precast panel was directly attached to the bottom of the damaged structural member by HCGS, and the degree of connection of the test specimens, strengthened by the section enlargement method, were quantitatively evaluated by PIT-based analysis. PMID:28788708
Ju, Hyunjin; Lee, Deuck Hang; Cho, Hae-Chang; Kim, Kang Su; Yoon, Seyoon; Seo, Soo-Yeon
2014-06-23
In this study, hydrophilic chemical grout using silanol (HCGS) was adopted to overcome the performance limitations of epoxy materials used for strengthening existing buildings and civil engineering structures. The enhanced material performances of HCGS were introduced, and applied to the section enlargement method, which is one of the typical structural strengthening methods used in practice. To evaluate the excellent structural strengthening performance of the HCGS, structural tests were conducted on reinforced concrete beams, and analyses on the flexural behaviors of test specimens were performed by modified partial interaction theory (PIT). In particular, to improve the constructability of the section enlargement method, an advanced strengthening method was proposed, in which the precast panel was directly attached to the bottom of the damaged structural member by HCGS, and the degree of connection of the test specimens, strengthened by the section enlargement method, were quantitatively evaluated by PIT-based analysis.
Evaluating the Maturity of Cybersecurity Programs for Building Control Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glantz, Clifford S.; Somasundaram, Sriram; Mylrea, Michael E.
The cyber-physical security threat to buildings is complex, non-linear, and rapidly evolving as operational and information technologies converge and connect buildings to cyberspace. Cyberattacks on buildings can exploit smart building controls and breach corporate networks, causing financial and reputational damage. This may result in the loss of sensitive building information or the disruption of, or damage to, the systems necessary for the safe and efficient operation of buildings. For the buildings and facility infrastructure, there is a need for a robust national cybersecurity strategy for buildings, guidance on the selection and implementation of appropriate cybersecurity controls for buildings, an approachmore » to evaluate the maturity and adequacy of the cybersecurity programs. To provide an approach for evaluating the maturity of the cybersecurity programs for building control systems, the US Department of Energy’s widely used Cybersecurity Capability and Maturity Model (C2M2) has been adapted into a building control systems version. The revised model, the Buildings-C2M2 (B-C2M2) provides maturity level indicators for cybersecurity programmatic domains. A “B-C2M2 Lite” version allows facility managers and building control system engineers, or information technology personnel to perform rapid self-assessments of their cybersecurity program. Both tools have been pilot tested on several facilities. This paper outlines the concept of a maturity model, describes the B-C2M2 tools, presents results and observations from the pilot assessments, and lays out plans for future work.« less
NASA Astrophysics Data System (ADS)
Huang, Yin-Nan
Nuclear power plants (NPPs) and spent nuclear fuel (SNF) are required by code and regulations to be designed for a family of extreme events, including very rare earthquake shaking, loss of coolant accidents, and tornado-borne missile impacts. Blast loading due to malevolent attack became a design consideration for NPPs and SNF after the terrorist attacks of September 11, 2001. The studies presented in this dissertation assess the performance of sample conventional and base isolated NPP reactor buildings subjected to seismic effects and blast loadings. The response of the sample reactor building to tornado-borne missile impacts and internal events (e.g., loss of coolant accidents) will not change if the building is base isolated and so these hazards were not considered. The sample NPP reactor building studied in this dissertation is composed of containment and internal structures with a total weight of approximately 75,000 tons. Four configurations of the reactor building are studied, including one conventional fixed-base reactor building and three base-isolated reactor buildings using Friction Pendulum(TM), lead rubber and low damping rubber bearings. The seismic assessment of the sample reactor building is performed using a new procedure proposed in this dissertation that builds on the methodology presented in the draft ATC-58 Guidelines and the widely used Zion method, which uses fragility curves defined in terms of ground-motion parameters for NPP seismic probabilistic risk assessment. The new procedure improves the Zion method by using fragility curves that are defined in terms of structural response parameters since damage and failure of NPP components are more closely tied to structural response parameters than to ground motion parameters. Alternate ground motion scaling methods are studied to help establish an optimal procedure for scaling ground motions for the purpose of seismic performance assessment. The proposed performance assessment procedure is used to evaluate the vulnerability of the conventional and base-isolated NPP reactor buildings. The seismic performance assessment confirms the utility of seismic isolation at reducing spectral demands on secondary systems. Procedures to reduce the construction cost of secondary systems in isolated reactor buildings are presented. A blast assessment of the sample reactor building is performed for an assumed threat of 2000 kg of TNT explosive detonated on the surface with a closest distance to the reactor building of 10 m. The air and ground shock waves produced by the design threat are generated and used for performance assessment. The air blast loading to the sample reactor building is computed using a Computational Fluid Dynamics code Air3D and the ground shock time series is generated using an attenuation model for soil/rock response. Response-history analysis of the sample conventional and base isolated reactor buildings to external blast loadings is performed using the hydrocode LS-DYNA. The spectral demands on the secondary systems in the isolated reactor building due to air blast loading are greater than those for the conventional reactor building but much smaller than those spectral demands associated with Safe Shutdown Earthquake shaking. The isolators are extremely effective at filtering out high acceleration, high frequency ground shock loading.
Do outdoor environmental noise and atmospheric NO2 levels spatially overlap in urban areas?
Tenailleau, Quentin M; Bernard, Nadine; Pujol, Sophie; Parmentier, Anne-Laure; Boilleaut, Mathieu; Houot, Hélène; Joly, Daniel; Mauny, Frédéric
2016-07-01
The urban environment holds numerous emission sources for air and noise pollution, creating optimum conditions for environmental multi-exposure situations. Evaluation of the joint-exposure levels is the main obstacle for multi-exposure studies and one of the biggest challenges of the next decade. The present study aims to describe the noise/NO2 multi-exposure situations in the urban environment by exploring the possible discordant and concordant situations of both exposures. Fine-scale diffusion models were developed in the European medium-sized city of Besançon (France), and a classification method was used to evaluate the multi-exposure situations in the façade perimeter of 10,825 buildings. Although correlated (Pearson's r = 0.64, p < 0.01), urban spatial distributions of the noise and NO2 around buildings do not overlap, and 30% of the buildings were considered to be discordant in terms of the noise and NO2 exposure levels. This discrepancy is spatially structured and associated with variables describing the building's environment. Our results support the presence of several co-existing, multi-exposure situations across the city impacted by both the urban morphology and the emission and diffusion/propagation phases of each pollutant. Identifying the mechanisms of discrepancy and convergence of multi-exposure situations could help improve the health risk assessment and public health. Copyright © 2016 Elsevier Ltd. All rights reserved.
Chen, Peng; Zhang, Jiquan; Sun, Yingyue; Liu, Xiaojing
2016-01-01
Urban waterlogging seriously threatens the safety of urban residents and properties. Wargame simulation research on resident emergency evacuation from waterlogged areas can determine the effectiveness of emergency response plans for high risk events at low cost. Based on wargame theory and emergency evacuation plans, we used a wargame exercise method, incorporating qualitative and quantitative aspects, to build an urban waterlogging disaster emergency shelter using a wargame exercise and evaluation model. The simulation was empirically tested in Daoli District of Harbin. The results showed that the wargame simulation scored 96.40 points, evaluated as good. From the simulation results, wargame simulation of urban waterlogging emergency procedures for disaster response can improve the flexibility and capacity for command, management and decision-making in emergency management departments. PMID:28009805
Tugwell, Peter; Pottie, Kevin; Welch, Vivian; Ueffing, Erin; Chambers, Andrea; Feightner, John
2011-01-01
Background: This article describes the evidence review and guideline development method developed for the Clinical Preventive Guidelines for Immigrants and Refugees in Canada by the Canadian Collaboration for Immigrant and Refugee Health Guideline Committee. Methods: The Appraisal of Guidelines for Research and Evaluation (AGREE) best-practice framework was combined with the recently developed Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach to produce evidence-based clinical guidelines for immigrants and refugees in Canada. Results: A systematic approach was designed to produce the evidence reviews and apply the GRADE approach, including building on evidence from previous systematic reviews, searching for and comparing evidence between general and specific immigrant populations, and applying the GRADE criteria for making recommendations. This method was used for priority health conditions that had been selected by practitioners caring for immigrants and refugees in Canada. Interpretation: This article outlines the 14-step method that was defined to standardize the guideline development process for each priority health condition. PMID:20573711
Hybrid Modeling Based on Scsg-Br and Orthophoto
NASA Astrophysics Data System (ADS)
Zhou, G.; Huang, Y.; Yue, T.; Li, X.; Huang, W.; He, C.; Wu, Z.
2018-05-01
With the development of digital city, digital applications are more and more widespread, while the urban buildings are more complex. Therefore, establishing an effective data model is the key to express urban building models accurately. In addition, the combination of 3D building model and remote sensing data become a trend to build digital city there are a large amount of data resulting in data redundancy. In order to solve the limitation of single modelling of constructive solid geometry (CSG), this paper presents a mixed modelling method based on SCSG-BR for urban buildings representation. On one hand, the improved CSG method, which is called as "Spatial CSG (SCSG)" representation method, is used to represent the exterior shape of urban buildings. On the other hand, the boundary representation (BR) method represents the topological relationship between geometric elements of urban building, in which the textures is considered as the attribute data of the wall and the roof of urban building. What's more, the method combined file database and relational database is used to manage the data of three-dimensional building model, which can decrease the complex processes in texture mapping. During the data processing, the least-squares algorithm with constraints is used to orthogonalize the building polygons and adjust the polygons topology to ensure the accuracy of the modelling data. Finally, this paper matches the urban building model with the corresponding orthophoto. This paper selects data of Denver, Colorado, USA to establish urban building realistic model. The results show that the SCSG-BR method can represent the topological relations of building more precisely. The organization and management of urban building model data reduce the redundancy of data and improve modelling speed. The combination of orthophoto and urban building model further strengthens the application in view analysis and spatial query, which enhance the scope of digital city applications.
300 Area Building Retention Evaluation Mitigation Plan
DOE Office of Scientific and Technical Information (OSTI.GOV)
D. J. McBride
2007-07-03
Evaluate the long-term retention of several facilities associated with the PNNL Capability Replacement Laboratory and other Hanfor mission needs. WCH prepared a mitigation plan for three scenarios with different release dates for specific buildings. The evaluations present a proposed plan for providing utility services to retained facilities in support of a long-term (+20 year) lifespan in addition to temporary services to buildings with specified delayed release dates.
Liu, Bin; Wang, Xiaolong; Lin, Lei; Dong, Qiwen; Wang, Xuan
2008-12-01
Protein remote homology detection and fold recognition are central problems in bioinformatics. Currently, discriminative methods based on support vector machine (SVM) are the most effective and accurate methods for solving these problems. A key step to improve the performance of the SVM-based methods is to find a suitable representation of protein sequences. In this paper, a novel building block of proteins called Top-n-grams is presented, which contains the evolutionary information extracted from the protein sequence frequency profiles. The protein sequence frequency profiles are calculated from the multiple sequence alignments outputted by PSI-BLAST and converted into Top-n-grams. The protein sequences are transformed into fixed-dimension feature vectors by the occurrence times of each Top-n-gram. The training vectors are evaluated by SVM to train classifiers which are then used to classify the test protein sequences. We demonstrate that the prediction performance of remote homology detection and fold recognition can be improved by combining Top-n-grams and latent semantic analysis (LSA), which is an efficient feature extraction technique from natural language processing. When tested on superfamily and fold benchmarks, the method combining Top-n-grams and LSA gives significantly better results compared to related methods. The method based on Top-n-grams significantly outperforms the methods based on many other building blocks including N-grams, patterns, motifs and binary profiles. Therefore, Top-n-gram is a good building block of the protein sequences and can be widely used in many tasks of the computational biology, such as the sequence alignment, the prediction of domain boundary, the designation of knowledge-based potentials and the prediction of protein binding sites.
NASA Astrophysics Data System (ADS)
Tamimi, E.; Ebadi, H.; Kiani, A.
2017-09-01
Automatic building detection from High Spatial Resolution (HSR) images is one of the most important issues in Remote Sensing (RS). Due to the limited number of spectral bands in HSR images, using other features will lead to improve accuracy. By adding these features, the presence probability of dependent features will be increased, which leads to accuracy reduction. In addition, some parameters should be determined in Support Vector Machine (SVM) classification. Therefore, it is necessary to simultaneously determine classification parameters and select independent features according to image type. Optimization algorithm is an efficient method to solve this problem. On the other hand, pixel-based classification faces several challenges such as producing salt-paper results and high computational time in high dimensional data. Hence, in this paper, a novel method is proposed to optimize object-based SVM classification by applying continuous Ant Colony Optimization (ACO) algorithm. The advantages of the proposed method are relatively high automation level, independency of image scene and type, post processing reduction for building edge reconstruction and accuracy improvement. The proposed method was evaluated by pixel-based SVM and Random Forest (RF) classification in terms of accuracy. In comparison with optimized pixel-based SVM classification, the results showed that the proposed method improved quality factor and overall accuracy by 17% and 10%, respectively. Also, in the proposed method, Kappa coefficient was improved by 6% rather than RF classification. Time processing of the proposed method was relatively low because of unit of image analysis (image object). These showed the superiority of the proposed method in terms of time and accuracy.
Building Assessment Survey and Evaluation Data (BASE)
The Building Assessment Survey and Evaluation (BASE) study was a five year study to characterize determinants of indoor air quality and occupant perceptions in representative public and commercial office buildings across the U.S. This data source is the raw data from this study about the indoor air quality.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-11
... characteristics? What are YouthBuild's impacts on crime and delinquency? What are the program's impacts on social... (ICR) for the Impact Evaluation of the YouthBuild Program; Comment Request AGENCY: Employment and..., collection instruments are clearly understood, and [[Page 27364
Design of stationary PEFC system configurations to meet heat and power demands
NASA Astrophysics Data System (ADS)
Wallmark, Cecilia; Alvfors, Per
This paper presents heat and power efficiencies of a modeled PEFC system and the methods used to create the system configuration. The paper also includes an example of a simulated fuel cell system supplying a building in Sweden with heat and power. The main method used to create an applicable fuel cell system configuration is pinch technology. This technology is used to evaluate and design a heat exchanger network for a PEFC system working under stationary conditions, in order to find a solution with high heat utilization. The heat exchanger network in the system connecting the reformer, the burner, gas cleaning, hot-water storage and the PEFC stack will affect the heat transferred to the hot-water storage and thereby the heating of the building. The fuel, natural gas, is reformed to a hydrogen-rich gas within a slightly pressurized system. The fuel processor investigated is steam reforming, followed by high- and low-temperature shift reactors and preferential oxidation. The system is connected to the electrical grid for backup and peak demands and to a hot-water storage to meet the varying heat demand for the building. The procedure for designing the fuel cell system installation as co-generation system is described, and the system is simulated for a specific building in Sweden during 1 year. The results show that the fuel cell system in combination with a burner and hot-water storage could supply the building with the required heat without exceeding any of the given limitations. The designed co-generation system will provide the building with most of its power requirements and would further generate income by sale of electricity to the power grid.
Dols, W Stuart; Emmerich, Steven J; Polidoro, Brian J
2016-08-01
Building modelers need simulation tools capable of simultaneously considering building energy use, airflow and indoor air quality (IAQ) to design and evaluate the ability of buildings and their systems to meet today's demanding energy efficiency and IAQ performance requirements. CONTAM is a widely-used multizone building airflow and contaminant transport simulation tool that requires indoor temperatures as input values. EnergyPlus is a prominent whole-building energy simulation program capable of performing heat transfer calculations that require interzone and infiltration airflows as input values. On their own, each tool is limited in its ability to account for thermal processes upon which building airflow may be significantly dependent and vice versa. This paper describes the initial phase of coupling of CONTAM with EnergyPlus to capture the interdependencies between airflow and heat transfer using co-simulation that allows for sharing of data between independently executing simulation tools. The coupling is accomplished based on the Functional Mock-up Interface (FMI) for Co-simulation specification that provides for integration between independently developed tools. A three-zone combined heat transfer/airflow analytical BESTEST case was simulated to verify the co-simulation is functioning as expected, and an investigation of a two-zone, natural ventilation case designed to challenge the coupled thermal/airflow solution methods was performed.
Natural Frequencies Evaluation on Partially Damaged Building using Ambient Vibration Technique
NASA Astrophysics Data System (ADS)
Kamarudin, A. F.; Zainal Abidin, M. H.; Daud, M. E.; Noh, M. S. Md; Madun, A.; Ibrahim, A.; Matarul, J.; Mokhatar, S. N.
2018-04-01
Severe damages observed on the school blocks, roads, retaining walls and drainage within the compound of SMK Kundasang Sabah possibly due to the ground movements triggered by the Ranau earthquake in 1991. Ambient vibration measurements were carried on the remaining demolished 3-storey building which partially damaged in order to measure the predominant building frequencies using tri-axial 1 Hz seismometer sensors. Popular methods of Horizontal-to-vertical spectral ratios (HVSR) and Fourier amplitude spectra (FAS) were used to compute the ambient vibration wave fields of each building axes (Transverse or North-South (NS), Longitudinal or East-West (EW) and vertical) into Fourier spectra. Two main modes of translation and torsion were observed from the peaks frequencies obtained at 2.99 to 3.10 Hz (1st mode), 4.85 Hz (2nd mode) and 5.63 to 5.85 Hz (3rd mode). The building experiencing translation modes of bending and shear in the NS and EW directions. It could be seen when the amplitudes tends to increase when the floor are increased. Meanwhile, the torsional bending mode is expected to occur when the deformation amplitudes are found to be increasing horizontally, when moving into partially structural damaged section located on the East wing of building.
Fabian, Maria Patricia; Adamkiewicz, Gary; Stout, Natasha Kay; Sandel, Megan; Levy, Jonathan Ian
2013-01-01
Background Although indoor environmental conditions can affect pediatric asthmatics, few studies have characterized the impact of building interventions on asthma-related outcomes. Simulation models can evaluate such complex systems but have not been applied in this context. Objective To evaluate the impacts of building interventions on indoor environmental quality and pediatric asthma healthcare utilization, and to conduct cost comparisons between intervention and healthcare costs, and energy savings. Methods We applied our previously developed discrete event simulation model (DEM) to simulate the effect of environmental factors, medication compliance, seasonality, and medical history on: 1) pollutant concentrations indoors, and 2) asthma outcomes in low-income multi-family housing. We estimated healthcare utilization and costs at baseline and subsequent to interventions, and then compared healthcare costs to energy savings and intervention costs. Results Interventions such as integrated pest management and repairing kitchen exhaust fans led to 7–12% reductions in serious asthma events with 1–3 year payback periods. Weatherization efforts targeted solely towards tightening a building envelope led to 20% more serious asthma events, but bundling with repairing kitchen exhaust fans and eliminating indoor sources (e.g. gas stoves or smokers) mitigated this impact. Conclusion Our pediatric asthma model provides a tool to prioritize individual and bundled building interventions based on their impact on health and cost, and highlighting the tradeoffs between weatherization, indoor air quality, and health. Our work bridges the gap between clinical and environmental health sciences by increasing physicians’ understanding of the impact that home environmental changes can have on their patients’ asthma. PMID:23910689
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neuhauser, K.
This project examines the implementation of an exterior insulation and over-clad strategy for brick masonry buildings in Chicago. The strategy was implemented at a free-standing two story two-family dwelling and a larger free-standing multifamily building. The test homes selected for this research represent predominant housing types for the Chicago area. High heating energy use typical in these buildings threaten housing affordability. Uninsulated mass masonry wall assemblies also have a strongly detrimental impact on comfort. Significant changes to the performance of masonry wall assemblies is generally beyond the reach of typical weatherization (Wx) program resources. The Community and Economic Development Associationmore » of Cook County, Inc. (CEDA) has secured a Sustainable Energy Resources for Consumers (SERC) innovation grant sponsored by the United States Department of Energy (DOE). This grant provides CEDA the opportunity to pursue a pilot implementation of innovative approaches to retrofit in masonry wall enclosures. The exterior insulation and over-clad strategy implemented through this project was designed to allow implementation by contractors active in CEDA weatherization programs and using materials and methods familiar to these contractors. The retrofit measures are evaluated in terms of feasibility, cost and performance. Through observations of the strategies implemented, the research described in this report identifies measures critical to performance as well as conditions for wider adoption. The research also identifies common factors that must be considered in determining whether the exterior insulation and over-clad strategy is appropriate for the building.« less
Lockwood, Charles
2006-06-01
Just five or six years ago, the term "green building" evoked visions of barefoot, tie-dyed, granola-munching denizens. There's been a large shift in perception. Of course, green buildings are still known for conserving natural resources by, for example, minimizing on-site grading, using alternative materials, and recycling construction waste. But people now see the financial advantages as well. Well-designed green buildings yield lower utility costs, greater employee productivity, less absenteeism, and stronger attraction and retention of workers than standard buildings do. Green materials, mechanical systems, and furnishings have become more widely available and considerably less expensive than they used to be-often cheaper than their standard counterparts. So building green is no longer a pricey experiment; just about any company can do it on a standard budget by following the ten rules outlined by the author. Reliable building-rating systems like the U.S. Green Building Council's rigorous Leadership in Energy and Environmental Design (LEED) program have done much to underscore the benefits of green construction. LEED evaluates buildings and awards points in several areas, such as water efficiency and indoor environmental quality. Other rating programs include the UK's BREEAM (Building Research Establishment's Environmental Assessment Method) and Australia's Green Star. Green construction is not simply getting more respect; it is rapidly becoming a necessity as corporations push it fully into the mainstream over the next five to ten years. In fact, the author says, the owners of standard buildings face massive obsolescence. To avoid this problem, they should carry out green renovations. Corporations no longer have an excuse for eschewing environmental and economic sustainability. They have at their disposal tools proven to lower overhead costs, improve productivity, and strengthen the bottom line.
Mohr, Johannes A; Jain, Brijnesh J; Obermayer, Klaus
2008-09-01
Quantitative structure activity relationship (QSAR) analysis is traditionally based on extracting a set of molecular descriptors and using them to build a predictive model. In this work, we propose a QSAR approach based directly on the similarity between the 3D structures of a set of molecules measured by a so-called molecule kernel, which is independent of the spatial prealignment of the compounds. Predictors can be build using the molecule kernel in conjunction with the potential support vector machine (P-SVM), a recently proposed machine learning method for dyadic data. The resulting models make direct use of the structural similarities between the compounds in the test set and a subset of the training set and do not require an explicit descriptor construction. We evaluated the predictive performance of the proposed method on one classification and four regression QSAR datasets and compared its results to the results reported in the literature for several state-of-the-art descriptor-based and 3D QSAR approaches. In this comparison, the proposed molecule kernel method performed better than the other QSAR methods.
Kuhn, Stefan; Egert, Björn; Neumann, Steffen; Steinbeck, Christoph
2008-09-25
Current efforts in Metabolomics, such as the Human Metabolome Project, collect structures of biological metabolites as well as data for their characterisation, such as spectra for identification of substances and measurements of their concentration. Still, only a fraction of existing metabolites and their spectral fingerprints are known. Computer-Assisted Structure Elucidation (CASE) of biological metabolites will be an important tool to leverage this lack of knowledge. Indispensable for CASE are modules to predict spectra for hypothetical structures. This paper evaluates different statistical and machine learning methods to perform predictions of proton NMR spectra based on data from our open database NMRShiftDB. A mean absolute error of 0.18 ppm was achieved for the prediction of proton NMR shifts ranging from 0 to 11 ppm. Random forest, J48 decision tree and support vector machines achieved similar overall errors. HOSE codes being a notably simple method achieved a comparatively good result of 0.17 ppm mean absolute error. NMR prediction methods applied in the course of this work delivered precise predictions which can serve as a building block for Computer-Assisted Structure Elucidation for biological metabolites.
2017-01-01
NHPA Building Evaluations at Fort Gordon” ERDC/CERL TR-17-3 ii Abstract This document is an architectural survey for 5 buildings (28414, Chapel...Hall) at Fort Gordon, Georgia. The Army constructed the 5 buildings from 1966 to 1977 and the 14 buildings in 1988. This survey satisfies Section...National Historic Preservation Act NPS National Park Service NRHP National Register of Historic Places USGS U.S. Geological Survey WWII World War II
DOE Office of Scientific and Technical Information (OSTI.GOV)
Griffith, B.; Deru M.; Torcellini, P.
2005-04-01
The Chesapeake Bay Foundation designed their new headquarters building to minimize its environmental impact on the already highly polluted Chesapeake Bay by incorporating numerous high-performance energy saving features into the building design. CBF then contacted NREL to perform a nonbiased energy evaluation of the building. Because their building attracted much attention in the sustainable design community, an unbiased evaluation was necessary to help designers replicate successes and identify and correct problem areas. This report focuses on NREL's monitoring and analysis of the overall energy performance of the building.
Devkota, J; Schlachter, H; Anand, C; Phillips, R; Apul, Defne
2013-11-30
Harvested rainwater systems and composting toilets are expected to be an important part of sustainable solutions in buildings. Yet, to this date, a model evaluating their economic and environmental impact has been missing. To address this need, a life cycle based model, EEAST was developed. EEAST was designed to compare the business as usual (BAU) case of using potable water for toilet flushing and irrigation to alternative scenarios of rainwater harvesting and composting toilet based technologies. In EEAST, building characteristics, occupancy, and precipitation are used to size the harvested rainwater and composting toilet systems. Then, life cycle costing and life cycle assessment methods are used to estimate cost, energy, and greenhouse gas (GHG) emission payback periods (PPs) for five alternative scenarios. The scenarios modeled include use of harvested rainwater for toilet flushing, for irrigation, or both; and use of composting toilets with or without harvested rainwater use for irrigation. A sample simulation using EEAST showed that for the office building modeled, the cost PPs were greater than energy PPs which in turn were greater than GHG emission PPs. This was primarily due to energy and emission intensive nature of the centralized water and wastewater infrastructure. The sample simulation also suggested that the composting toilets may have the best performance in all criteria. However, EEAST does not explicitly model solids management and as such may give composting toilets an unfair advantage compared to flush based toilets. EEAST results were found to be very sensitive to cost values used in the model. With the availability of EEAST, life cycle cost, energy, and GHG emissions can now be performed fairly easily by building designers and researchers. Future work is recommended to further improve EEAST and evaluate it for different types of buildings and climates so as to better understand when composting toilets and harvested rainwater systems outperform the BAU case in building design. Copyright © 2013 Elsevier Ltd. All rights reserved.
Dannenberg, Andrew L.; Bhatia, Rajiv; Cole, Brian L.; Dora, Carlos; Fielding, Jonathan E.; Kraft, Katherine; McClymont-Peace, Diane; Mindell, Jennifer; Onyekere, Chinwe; Roberts, James A.; Ross, Catherine L.; Rutt, Candace D.; Scott-Samuel, Alex; Tilson, Hugh H.
2006-01-01
Health impact assessment (HIA) methods are used to evaluate the impact on health of policies and projects in community design, transportation planning, and other areas outside traditional public health concerns. At an October 2004 workshop, domestic and international experts explored issues associated with advancing the use of HIA methods by local health departments, planning commissions, and other decisionmakers in the United States. Workshop participants recommended conducting pilot tests of existing HIA tools, developing a database of health impacts of common projects and policies, developing resources for HIA use, building workforce capacity to conduct HIAs, and evaluating HIAs. HIA methods can influence decisionmakers to adjust policies and projects to maximize benefits and minimize harm to the public’s health. PMID:16380558
Building an Evaluative Culture: The Key to Effective Evaluation and Results Management
ERIC Educational Resources Information Center
Mayne, John
2009-01-01
As many reviews of results-based performance systems have noted, a weak evaluative culture in an organization undermines attempts at building an effective evaluation and/or results management regime. This article sets out what constitutes a strong evaluative culture where information on performance results is deliberately sought in order to learn…
Work engagement of older registered nurses: the impact of a caring-based intervention.
Bishop, Mary
2013-10-01
The aim of this evaluation research was to measure the impact of a caring-based intervention on the level of work engagement in older nurses. Every effort is needed to retain older nurses at the bedside by assisting them to revitalise the internal motivation and self- reward that brought them to nursing. A mixed method evaluation research approach using both qualitative and quantitative measurements was used to determine the impact of a caring-based programme on improving the work engagement scores of older Registered Nurses (RNs). The results of this study suggest that leadership strategies aimed at improving work engagement using caring theories have a significant positive impact. The findings contribute to our understanding of how work engagement can be enhanced through building work environments where there is a sense of belonging and teamwork, where staff are allowed time to decompress as well as build positive work relationships. Nurse Leaders (NLs) bear a responsibility to partner with older Registered Nurses (RNs) to build engagement in their work life while enhancing the quality of care. Successful leaders will find ways to meet these unique challenges by creating a healthy work environment. © 2013 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Rolita, Lisa; Surarso, Bayu; Gernowo, Rahmat
2018-02-01
In order to improve airport safety management system (SMS) performance, an evaluation system is required to improve on current shortcomings and maximize safety. This study suggests the integration of the DEMATEL and ANP methods in decision making processes by analyzing causal relations between the relevant criteria and taking effective analysis-based decision. The DEMATEL method builds on the ANP method in identifying the interdependencies between criteria. The input data consists of questionnaire data obtained online and then stored in an online database. Furthermore, the questionnaire data is processed using DEMATEL and ANP methods to obtain the results of determining the relationship between criteria and criteria that need to be evaluated. The study cases on this evaluation system were Adi Sutjipto International Airport, Yogyakarta (JOG); Ahmad Yani International Airport, Semarang (SRG); and Adi Sumarmo International Airport, Surakarta (SOC). The integration grades SMS performance criterion weights in a descending order as follow: safety and destination policy, safety risk management, healthcare, and safety awareness. Sturges' formula classified the results into nine grades. JOG and SMG airports were in grade 8, while SOG airport was in grade 7.
Data-Driven Benchmarking of Building Energy Efficiency Utilizing Statistical Frontier Models
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kavousian, A; Rajagopal, R
2014-01-01
Frontier methods quantify the energy efficiency of buildings by forming an efficient frontier (best-practice technology) and by comparing all buildings against that frontier. Because energy consumption fluctuates over time, the efficiency scores are stochastic random variables. Existing applications of frontier methods in energy efficiency either treat efficiency scores as deterministic values or estimate their uncertainty by resampling from one set of measurements. Availability of smart meter data (repeated measurements of energy consumption of buildings) enables using actual data to estimate the uncertainty in efficiency scores. Additionally, existing applications assume a linear form for an efficient frontier; i.e.,they assume that themore » best-practice technology scales up and down proportionally with building characteristics. However, previous research shows that buildings are nonlinear systems. This paper proposes a statistical method called stochastic energy efficiency frontier (SEEF) to estimate a bias-corrected efficiency score and its confidence intervals from measured data. The paper proposes an algorithm to specify the functional form of the frontier, identify the probability distribution of the efficiency score of each building using measured data, and rank buildings based on their energy efficiency. To illustrate the power of SEEF, this paper presents the results from applying SEEF on a smart meter data set of 307 residential buildings in the United States. SEEF efficiency scores are used to rank individual buildings based on energy efficiency, to compare subpopulations of buildings, and to identify irregular behavior of buildings across different time-of-use periods. SEEF is an improvement to the energy-intensity method (comparing kWh/sq.ft.): whereas SEEF identifies efficient buildings across the entire spectrum of building sizes, the energy-intensity method showed bias toward smaller buildings. The results of this research are expected to assist researchers and practitioners compare and rank (i.e.,benchmark) buildings more robustly and over a wider range of building types and sizes. Eventually, doing so is expected to result in improved resource allocation in energy-efficiency programs.« less
NASA Astrophysics Data System (ADS)
Latief, Yusuf; Berawi, Mohammed Ali; Basten, Van; Riswanto; Budiman, Rachmat
2017-07-01
Green building concept becomes important in current building life cycle to mitigate environment issues. The purpose of this paper is to optimize building construction performance towards green building premium cost, achieving green building rating tools with optimizing life cycle cost. Therefore, this study helps building stakeholder determining building fixture to achieve green building certification target. Empirically the paper collects data of green building in the Indonesian construction industry such as green building fixture, initial cost, operational and maintenance cost, and certification score achievement. After that, using value engineering method optimized green building fixture based on building function and cost aspects. Findings indicate that construction performance optimization affected green building achievement with increasing energy and water efficiency factors and life cycle cost effectively especially chosen green building fixture.
Matsubara, Hiroki; Kikugawa, Gota; Ishikiriyama, Mamoru; Yamashita, Seiji; Ohara, Taku
2017-09-21
Thermal conductivity of a material can be comprehended as being composed of microscopic building blocks relevant to the energy transfer due to a specific microscopic process or structure. The building block is called the partial thermal conductivity (PTC). The concept of PTC is essential to evaluate the contributions of various molecular mechanisms to heat conduction and has been providing detailed knowledge of the contribution. The PTC can be evaluated by equilibrium molecular dynamics (EMD) and non-equilibrium molecular dynamics (NEMD) in different manners: the EMD evaluation utilizes the autocorrelation of spontaneous heat fluxes in an equilibrium state whereas the NEMD one is based on stationary heat fluxes in a non-equilibrium state. However, it has not been fully discussed whether the two methods give the same PTC or not. In the present study, we formulate a Green-Kubo relation, which is necessary for EMD to calculate the PTCs equivalent to those by NEMD. Unlike the existing theories, our formulation is based on the local equilibrium hypothesis to describe a clear connection between EMD and NEMD simulations. The equivalence of the two derivations of PTCs is confirmed by the numerical results for liquid methane and butane. The present establishment of the EMD-NEMD correspondence makes the MD analysis of PTCs a robust way to clarify the microscopic origins of thermal conductivity.
Evaluation of seismic performance of reinforced concrete (RC) buildings under near-field earthquakes
NASA Astrophysics Data System (ADS)
Moniri, Hassan
2017-03-01
Near-field ground motions are significantly severely affected on seismic response of structure compared with far-field ground motions, and the reason is that the near-source forward directivity ground motions contain pulse-long periods. Therefore, the cumulative effects of far-fault records are minor. The damage and collapse of engineering structures observed in the last decades' earthquakes show the potential of damage in existing structures under near-field ground motions. One important subject studied by earthquake engineers as part of a performance-based approach is the determination of demand and collapse capacity under near-field earthquake. Different methods for evaluating seismic structural performance have been suggested along with and as part of the development of performance-based earthquake engineering. This study investigated the results of illustrious characteristics of near-fault ground motions on the seismic response of reinforced concrete (RC) structures, by the use of Incremental Nonlinear Dynamic Analysis (IDA) method. Due to the fact that various ground motions result in different intensity-versus-response plots, this analysis is done again under various ground motions in order to achieve significant statistical averages. The OpenSees software was used to conduct nonlinear structural evaluations. Numerical modelling showed that near-source outcomes cause most of the seismic energy from the rupture to arrive in a single coherent long-period pulse of motion and permanent ground displacements. Finally, a vulnerability of RC building can be evaluated against pulse-like near-fault ground motions effects.
[Biological pollution and allergic diseases].
Carrer, P; Moscato, G
2004-01-01
House dust mites, pets, microorganisms such as fungi and bacteria are the main causes of indoor allergens. The diseases correlated to the presence of these allergens are of increasing importance in public health as well as in occupational medicine. Indoor allergens are widespread in residential buildings as well as in public and in office buildings. Surveys conducted in Italian office buildings demonstrated detectable allergen concentrations in most of these buildings. In some cases, the concentrations were higher than the proposed risk threshold for allergenic sensitisation or for the elicitation of symptoms in allergic individuals. The health effects of exposure to indoor allergens mainly include allergic asthma and rhinoconjunctivitis caused by IgE reactions in predisposed subjects. Moreover, exposure to indoor biological agents can cause extrinsic allergic alveolitis or other effects such as the so-called "humidifier fever" due to contaminated humidifiers. Standardized methods for the measurement of indoor allergen levels are available, and may be useful for the diagnosis and treatment of individual allergic patients or for group studies in order to evaluate the relationship between allergen indoor levels and health effects or to assess indoor allergen levels in private or public buildings for preventative purposes.
A novel methodology for building robust design rules by using design based metrology (DBM)
NASA Astrophysics Data System (ADS)
Lee, Myeongdong; Choi, Seiryung; Choi, Jinwoo; Kim, Jeahyun; Sung, Hyunju; Yeo, Hyunyoung; Shim, Myoungseob; Jin, Gyoyoung; Chung, Eunseung; Roh, Yonghan
2013-03-01
This paper addresses a methodology for building robust design rules by using design based metrology (DBM). Conventional method for building design rules has been using a simulation tool and a simple pattern spider mask. At the early stage of the device, the estimation of simulation tool is poor. And the evaluation of the simple pattern spider mask is rather subjective because it depends on the experiential judgment of an engineer. In this work, we designed a huge number of pattern situations including various 1D and 2D design structures. In order to overcome the difficulties of inspecting many types of patterns, we introduced Design Based Metrology (DBM) of Nano Geometry Research, Inc. And those mass patterns could be inspected at a fast speed with DBM. We also carried out quantitative analysis on PWQ silicon data to estimate process variability. Our methodology demonstrates high speed and accuracy for building design rules. All of test patterns were inspected within a few hours. Mass silicon data were handled with not personal decision but statistical processing. From the results, robust design rules are successfully verified and extracted. Finally we found out that our methodology is appropriate for building robust design rules.
NASA Astrophysics Data System (ADS)
Lin, D.; Jarzabek-Rychard, M.; Schneider, D.; Maas, H.-G.
2018-05-01
An automatic building façade thermal texture mapping approach, using uncooled thermal camera data, is proposed in this paper. First, a shutter-less radiometric thermal camera calibration method is implemented to remove the large offset deviations caused by changing ambient environment. Then, a 3D façade model is generated from a RGB image sequence using structure-from-motion (SfM) techniques. Subsequently, for each triangle in the 3D model, the optimal texture is selected by taking into consideration local image scale, object incident angle, image viewing angle as well as occlusions. Afterwards, the selected textures can be further corrected using thermal radiant characteristics. Finally, the Gauss filter outperforms the voted texture strategy at the seams smoothing and thus for instance helping to reduce the false alarm rate in façade thermal leakages detection. Our approach is evaluated on a building row façade located at Dresden, Germany.
Park, Seonghyun; Seo, Janghoo
2016-04-01
Reinforcing the insulation and airtightness of buildings and the use of building materials containing new chemical substances have caused indoor air quality problems. Use of sorptive building materials along with removal of pollutants, constant ventilation, bake-out, etc. are gaining attention in Korea and Japan as methods for improving such indoor air quality problems. On the other hand, sorptive building materials are considered a passive method of reducing the concentration of pollutants, and their application should be reviewed in the early stages. Thus, in this research, activated carbon was prepared as a sorptive building material. Then, computational fluid dynamics (CFD) was conducted, and a method for optimal installation of sorptive building materials was derived according to the indoor environment using the contribution ratio of pollution source (CRP) index. The results show that a method for optimal installation of sorptive building materials can be derived by predicting the contribution ratio of pollutant sources according to the CRP index.
NASA Astrophysics Data System (ADS)
Spišáková, Marcela; Mačková, Daniela
2015-11-01
The sustainable building has taken off in recent years with many investors looking for new and different methods of construction. The traditional building materials can be made out of natural materials, while others can help to lower energy costs of the occupant once built. Regardless of what the goal of the investor is, traditional building materials and their use is on the rise. The submitted paper provides an overview of natural building materials and possible modern building systems using these construction materials. Based on the questionnaire survey is defined the use potential of traditional building materials for the realization of the construction by methods of modern constructions and then are determined the drivers and barriers of traditional materials through using modern methods of construction. Considering the analysis of the achieved results, we can identify the gaps in the construction market in Slovakia and also to assess the perception of potential investors in the field of traditional building materials use, which is the purpose of submitted paper.
1. VIEW LOOKING NORTHWEST AT BUILDING 701. BUILDING 701 WAS ...
1. VIEW LOOKING NORTHWEST AT BUILDING 701. BUILDING 701 WAS USED TO DESIGN, BUILD, AND EVALUATE BENCH-SCALE TECHNOLOGIES USED IN ROCKY FLATS WASTE TREATMENT PROCESSES. (1/98) - Rocky Flats Plant, Design Laboratory, Northwest quadrant of Plant, between buildings 776-777 & 771, Golden, Jefferson County, CO
NASA Astrophysics Data System (ADS)
Wu, Jiangning; Wang, Xiaohuan
Rapidly increasing amount of mobile phone users and types of services leads to a great accumulation of complaining information. How to use this information to enhance the quality of customers' services is a big issue at present. To handle this kind of problem, the paper presents an approach to construct a domain knowledge map for navigating the explicit and tacit knowledge in two ways: building the Topic Map-based explicit knowledge navigation model, which includes domain TM construction, a semantic topic expansion algorithm and VSM-based similarity calculation; building Social Network Analysis-based tacit knowledge navigation model, which includes a multi-relational expert navigation algorithm and the criterions to evaluate the performance of expert networks. In doing so, both the customer managers and operators in call centers can find the appropriate knowledge and experts quickly and exactly. The experimental results show that the above method is very powerful for knowledge navigation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Takeda, Masatoshi; Komura, Toshiyuki; Hirotani, Tsutomu
1995-12-01
Annual failure probabilities of buildings and equipment were roughly evaluated for two fusion-reactor-like buildings, with and without seismic base isolation, in order to examine the effectiveness of the base isolation system regarding siting issues. The probabilities are calculated considering nonlinearity and rupture of isolators. While the probability of building failure for both buildings on the same site was almost equal, the function failures for equipment showed that the base-isolated building had higher reliability than the non-isolated building. Even if the base-isolated building alone is located on a higher seismic hazard area, it could compete favorably with the ordinary one inmore » reliability of equipment.« less
Lambert, Mark; Bellamy, Fiona; Budgey, Richard; Callaby, Rebecca; Coats, Julia; Talling, Janet
2018-01-01
Indices of rodent activity are used as indicators of population change during field evaluation of rodenticides. We investigated the potential for using camera traps to determine activity indices for commensal rodents living in and around farm buildings, and sought to compare these indices against previously calibrated survey methods. We recorded 41 263 images of 23 species, including Norway rats (Rattus norvegicus Berk.) and house mice (Mus musculus L.). We found a positive correlation between activity indices from camera traps and activity indices from a method (footprint tracking) previously shown to have a linear relationship with population size for Norway rats. Filtering the camera trap data to simulate a 30-s delay between camera trigger events removed 59.9% of data and did not adversely affect the correlation between activity indices from camera traps and footprint tracking. The relationship between activity indices from footprint tracking and Norway rat population size is known from a previous study; from this, we determined the relationship between activity indices from camera traps and population size for Norway rats living in and around farm buildings. Systematic use of camera traps was used to determine activity indices for Norway rats living in and around farm buildings; the activity indices were positively correlated with those derived from a method previously calibrated against known population size for this species in this context. © 2017 Crown copyright. Pest Management Science © 2017 Society of Chemical Industry. © 2017 Crown copyright. Pest Management Science © 2017 Society of Chemical Industry.
Brownstein, John S; Cassa, Christopher A; Kohane, Isaac S; Mandl, Kenneth D
2006-12-08
Widespread availability of geographic information systems software has facilitated the use of disease mapping in academia, government and private sector. Maps that display the address of affected patients are often exchanged in public forums, and published in peer-reviewed journal articles. As previously reported, a search of figure legends in five major medical journals found 19 articles from 1994-2004 that identify over 19,000 patient addresses. In this report, a method is presented to evaluate whether patient privacy is being breached in the publication of low-resolution disease maps. To demonstrate the effect, a hypothetical low-resolution map of geocoded patient addresses was created and the accuracy with which patient addresses can be resolved is described. Through georeferencing and unsupervised classification of the original image, the method precisely re-identified 26% (144/550) of the patient addresses from a presentation quality map and 79% (432/550) from a publication quality map. For the presentation quality map, 99.8% of the addresses were within 70 meters (approximately one city block length) of the predicted patient location, 51.6% of addresses were identified within five buildings, 70.7% within ten buildings and 93% within twenty buildings. For the publication quality map, all addresses were within 14 meters and 11 buildings of the predicted patient location. This study demonstrates that lowering the resolution of a map displaying geocoded patient addresses does not sufficiently protect patient addresses from re-identification. Guidelines to protect patient privacy, including those of medical journals, should reflect policies that ensure privacy protection when spatial data are displayed or published.
Rastogi, Vipin K.; Ryan, Shawn P.; Wallace, Lalena; Smith, Lisa S.; Shah, Saumil S.; Martin, G. Blair
2010-01-01
Efficacy of chlorine dioxide (CD) gas generated by two distinct generation systems, Sabre (wet system with gas generated in water) and ClorDiSys (dry system with gas generated in air), was evaluated for inactivation of Bacillus anthracis spores on six building interior surfaces. The six building materials included carpet, acoustic ceiling tile, unpainted cinder block, painted I-beam steel, painted wallboard, and unpainted pinewood. There was no statistically significant difference in the data due to the CD generation technology at a 95% confidence level. Note that a common method of CD gas measurement was used for both wet and dry CD generation types. Doses generated by combinations of different concentrations of CD gas (500, 1,000, 1,500, or 3,000 parts per million of volume [ppmv]) and exposure times (ranging between 0.5 and 12 h) were used to evaluate the relative role of fumigant exposure period and total dose in the decontamination of building surfaces. The results showed that the time required to achieve at least a 6-log reduction in viable spores is clearly a function of the material type on which the spores are inoculated. The wood and cinder block coupons required a longer exposure time to achieve a 6-log reduction. The only material showing a clear statistical difference in rate of decay of viable spores as a function of concentration was cinder block. For all other materials, the profile of spore kill (i.e., change in number of viable spores with exposure time) was not dependent upon fumigant concentration (500 to 3,000 ppmv). The CD dose required for complete spore kill on biological indicators (typically, 1E6 spores of Bacillus atrophaeus on stainless steel) was significantly less than that required for decontamination of most of the building materials tested. PMID:20305025
Rastogi, Vipin K; Ryan, Shawn P; Wallace, Lalena; Smith, Lisa S; Shah, Saumil S; Martin, G Blair
2010-05-01
Efficacy of chlorine dioxide (CD) gas generated by two distinct generation systems, Sabre (wet system with gas generated in water) and ClorDiSys (dry system with gas generated in air), was evaluated for inactivation of Bacillus anthracis spores on six building interior surfaces. The six building materials included carpet, acoustic ceiling tile, unpainted cinder block, painted I-beam steel, painted wallboard, and unpainted pinewood. There was no statistically significant difference in the data due to the CD generation technology at a 95% confidence level. Note that a common method of CD gas measurement was used for both wet and dry CD generation types. Doses generated by combinations of different concentrations of CD gas (500, 1,000, 1,500, or 3,000 parts per million of volume [ppmv]) and exposure times (ranging between 0.5 and 12 h) were used to evaluate the relative role of fumigant exposure period and total dose in the decontamination of building surfaces. The results showed that the time required to achieve at least a 6-log reduction in viable spores is clearly a function of the material type on which the spores are inoculated. The wood and cinder block coupons required a longer exposure time to achieve a 6-log reduction. The only material showing a clear statistical difference in rate of decay of viable spores as a function of concentration was cinder block. For all other materials, the profile of spore kill (i.e., change in number of viable spores with exposure time) was not dependent upon fumigant concentration (500 to 3,000 ppmv). The CD dose required for complete spore kill on biological indicators (typically, 1E6 spores of Bacillus atrophaeus on stainless steel) was significantly less than that required for decontamination of most of the building materials tested.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Yixing; Zhang, Jianshun; Pelken, Michael
Executive Summary The objective of this study was to develop a “Virtual Design Studio (VDS)”: a software platform for integrated, coordinated and optimized design of green building systems with low energy consumption, high indoor environmental quality (IEQ), and high level of sustainability. This VDS is intended to assist collaborating architects, engineers and project management team members throughout from the early phases to the detailed building design stages. It can be used to plan design tasks and workflow, and evaluate the potential impacts of various green building strategies on the building performance by using the state of the art simulation toolsmore » as well as industrial/professional standards and guidelines for green building system design. Engaged in the development of VDS was a multi-disciplinary research team that included architects, engineers, and software developers. Based on the review and analysis of how existing professional practices in building systems design operate, particularly those used in the U.S., Germany and UK, a generic process for performance-based building design, construction and operation was proposed. It distinguishes the whole process into five distinct stages: Assess, Define, Design, Apply, and Monitoring (ADDAM). The current VDS is focused on the first three stages. The VDS considers building design as a multi-dimensional process, involving multiple design teams, design factors, and design stages. The intersection among these three dimensions defines a specific design task in terms of “who”, “what” and “when”. It also considers building design as a multi-objective process that aims to enhance the five aspects of performance for green building systems: site sustainability, materials and resource efficiency, water utilization efficiency, energy efficiency and impacts to the atmospheric environment, and IEQ. The current VDS development has been limited to energy efficiency and IEQ performance, with particular focus on evaluating thermal performance, air quality and lighting environmental quality because of their strong interaction with the energy performance of buildings. The VDS software framework contains four major functions: 1) Design coordination: It enables users to define tasks using the Input-Process-Output flow approach, which specifies the anticipated activities (i.e., the process), required input and output information, and anticipated interactions with other tasks. It also allows task scheduling to define the work flow, and sharing of the design data and information via the internet. 2) Modeling and simulation: It enables users to perform building simulations to predict the energy consumption and IEQ conditions at any of the design stages by using EnergyPlus and a combined heat, air, moisture and pollutant simulation (CHAMPS) model. A method for co-simulation was developed to allow the use of both models at the same time step for the combined energy and indoor air quality analysis. 3) Results visualization: It enables users to display a 3-D geometric design of the building by reading BIM (building information model) file generated by design software such as SketchUp, and the predicted results of heat, air, moisture, pollutant and light distributions in the building. 4) Performance evaluation: It enables the users to compare the performance of a proposed building design against a reference building that is defined for the same type of buildings under the same climate condition, and predicts the percent of improvements over the minimum requirements specified in ASHRAE Standard 55-2010, 62.1-2010 and 90.1-2010. An approach was developed to estimate the potential impact of a design factor on the whole building performance, and hence can assist the user to identify areas that have most pay back for investment. The VDS software was developed by using C++ with the conventional Model, View and Control (MVC) software architecture. The software has been verified by using a simple 3-zone case building. The application of the VDS concepts and framework for building design and performance analysis has been illustrated by using a medium-sized, five story office building that received LEED Platinum Certification from USGBC.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-15
..., earnings, and job characteristics? What are YouthBuild's impacts on crime and delinquency? What are the... Collection for the Impact Evaluation of the YouthBuild Program; New Collection AGENCY: Employment and... instruments are clearly understood, and the impact of collection requirements on respondents can be properly...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-08
... job characteristics? What are YouthBuild's impacts on crime and delinquency? What are the program's... (ICR) for the Impact Evaluation of the YouthBuild Program; New Collection AGENCY: Employment and... instruments are clearly understood, and the impact of collection requirements on respondents can be properly...
Building Environmental Educators' Evaluation Capacity through Distance Education
ERIC Educational Resources Information Center
Fleming, M. Lynette; Easton, Janice
2010-01-01
Evaluation capacity building (ECB) is seldom mentioned in the environmental education (EE) literature, but as demonstrated by the lack and poor quality of EE evaluations, is much needed. This article focuses on an online course, Applied Environmental Education Program Evaluation (AEEPE), which provides nonformal educators with an understanding of…
Evaluation Capacity Building: Can a Classroom-Based Course Make a Difference?
ERIC Educational Resources Information Center
Kaye-Tzadok, Avital; Spiro, Shimon E.
2016-01-01
Purpose: Growing emphasis on program and practice evaluation in social work education coalesces with a growing interest in evaluation capacity building (ECB) within the interdisciplinary field of evaluation. However, the literature on ECB, while recognizing the importance of imparting knowledge and skills to individuals, largely ignores the…
Planning Under Uncertainty: Methods and Applications
2010-06-09
begun research into fundamental algorithms for optimization and re?optimization of continuous optimization problems (such as linear and quadratic... algorithm yields a 14.3% improvement over the original design while saving 68.2 % of the simulation evaluations compared to standard sample-path...They provide tools for building and justifying computational algorithms for such problems. Year. 2010 Month: 03 Final Research under this grant
Building "e-rater"® Scoring Models Using Machine Learning Methods. Research Report. ETS RR-16-04
ERIC Educational Resources Information Center
Chen, Jing; Fife, James H.; Bejar, Isaac I.; Rupp, André A.
2016-01-01
The "e-rater"® automated scoring engine used at Educational Testing Service (ETS) scores the writing quality of essays. In the current practice, e-rater scores are generated via a multiple linear regression (MLR) model as a linear combination of various features evaluated for each essay and human scores as the outcome variable. This…
Low Frequency Vibration approach to asess the Performance of wood structural Systems
Xiping Wang; Robert J. Ross; Michael O. Hunt
2004-01-01
The primary means of inspecting buildings and other structures is to evaluate each structure member individually. This is a time consuming process that is expensive, particularly if sheathing or other covering materials must be removed to access the structural members. This paper presents an effort to use a low frequency vibration method for assessing the structural...
Low frequency vibration approach for assessing performance of wood floor systems
Xiping Wang; Robert J. Ross; Michael O. Hunt; John R. Erickson; John W. Forsman
2005-01-01
The primary means of inspecting buildings and other structures is to evaluate each structure member individually. This is a time-consuming and expensive process, particularly if sheathing or other covering materials must be removed to access the structural members. The objective of this study was to determine if a low frequency vibration method could be used to...
ERIC Educational Resources Information Center
Alqurashi, Emtinan; Gokbel, Elif N.; Carbonara, David
2017-01-01
Teachers' technological pedagogical content knowledge (TPACK) involves an awareness of instructional approaches, methods, and knowledge of building on technology to enhance students' learning. The purpose of this study was to evaluate the TPACK of teachers in Saudi Arabia and USA, and then describe the factors affecting teachers' TPACK through an…
Schreuder, Eliane; van Heel, Liesbeth; Goedhart, Rien; Dusseldorp, Elise; Schraagen, Jan Maarten; Burdorf, Alex
2015-01-01
This study investigates effects of the newly built nonpatient-related buildings of a large university medical center on staff perceptions and whether the design objectives were achieved. The medical center is gradually renewing its hospital building area of 200,000 m.(2) This redevelopment is carefully planned and because lessons learned can guide design decisions of the next phase, the medical center is keen to evaluate the performance of the new buildings. A pre- and post-study with a control group was conducted. Prior to the move to the new buildings an occupancy evaluation was carried out in the old setting (n = 729) (pre-study). Post occupation of the new buildings another occupancy evaluation (post-study) was carried out in the new setting (intervention group) and again in some old settings (control group) (n = 664). The occupancy evaluation consisted of an online survey that measured the perceived performance of different aspects of the building. Longitudinal multilevel analysis was used to compare the performance of the old buildings with the new buildings. Significant improvements were found in indoor climate, perceived safety, working environment, well-being, facilities, sustainability, and overall satisfaction. Commitment to the employer, working atmosphere, orientation, work performance, and knowledge sharing did not improve. The results were interpreted by relating them to specific design choices. We showed that it is possible to measure the performance improvements of a complex intervention being a new building design and validate design decisions. A focused design process aiming for a safe, pleasant and sustainable building resulted in actual improvements in some of the related performance measures. © The Author(s) 2015.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meyer, R.T.; Coe, B.A.; Dick, J.D.
1981-01-01
Four state-owned building complexes ahve been evaluated within the city of Durango: The State Fish Hatchery, Fort Lewis College, new State Highway Department Building near the Bodo Industrial Park, and the National Guard Building. Three of the state facilities in Durango are evaluated for geothermal systems on thea ssumption of taking geothermal water from a trunk-line originating at the area northof Durango: State Fish Hatchery, Fort Lewis College and new State Highway Department Building. The National Guard Building is evaluated on the basis of a water-to-air heat pump, with warm water derived from a hypothetical shallow aquifer immediately below themore » building site. Two geothermal options were separately evaluated for Fort Lewis College: a central heat exchanger system for delivery of 145/sup 0/F heating water to the campus buildings and a central heat pump system for boosting the heating water to 200/sup 0/F prior to delivery to the buildings; both systems require the installation of a distribution piping network for the entire campus area. Retrofit engineering for the State Fish Hatchery provides for the installation of a small scale central distribution piping system to the several buildings, a central heat excanger coupled to the geothermal trunk line, and the use of various fan coil and unit heaters for space heating. An option is provided for discharge-mixing the geothermal water into the fish ponds and runs in order to raise the hatchery water temperature a couple degrees for increasing fish production and yield. The heating system for the new State Highway Department Building is redesigned to replace the natural-gas-fired forced-air furnaces with a heat exchanger, hot water fan coils and unit heaters.« less
Scout: An Impact Analysis Tool for Building Energy-Efficiency Technologies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harris, Chioke; Langevin, Jared; Roth, Amir
Evaluating the national impacts of candidate U.S. building energy-efficiency technologies has historically been difficult for organizations with large energy efficiency portfolios. In particular, normalizing results from technology-specific impact studies is time-consuming when those studies do not use comparable assumptions about the underlying building stock. To equitably evaluate its technology research, development, and deployment portfolio, the U.S. Department of Energy's Building Technologies Office has developed Scout, a software tool that quantitatively assesses the energy and CO2 impacts of building energy-efficiency measures on the national building stock. Scout efficiency measures improve upon the unit performance and/or lifetime operational costs of an equipmentmore » stock baseline that is determined from the U.S. Energy Information Administration Annual Energy Outlook (AEO). Scout measures are characterized by a market entry and exit year, unit performance level, cost, and lifetime. To evaluate measures on a consistent basis, Scout uses EnergyPlus simulation on prototype building models to translate measure performance specifications to whole-building energy savings; these savings impacts are then extended to a national scale using floor area weighting factors. Scout represents evolution in the building stock over time using AEO projections for new construction, retrofit, and equipment replacements, and competes technologies within market segments under multiple adoption scenarios. Scout and its efficiency measures are open-source, as is the EnergyPlus whole building simulation framework that is used to evaluate measure performance. The program is currently under active development and will be formally released once an initial set of measures has been analyzed and reviewed.« less
Identifying Populace Susceptible to Flooding Using ArcGIS and Remote Sensing Datasets
NASA Astrophysics Data System (ADS)
Fernandez, Sim Joseph; Milano, Alan
2016-07-01
Remote sensing technologies are growing vastly as with its various applications. The Department of Science and Technology (DOST), Republic of the Philippines, has made projects exploiting LiDAR datasets from remote sensing technologies. The Phil-LiDAR 1 project of DOST is a flood hazard mapping project. Among the project's objectives is the identification of building features which can be associated to the flood-exposed population. The extraction of building features from the LiDAR dataset is arduous as it requires manual identification of building features on an elevation map. The mapping of building footprints is made meticulous in order to compensate the accuracy between building floor area and building height both of which are crucial in flood decision making. A building identification method was developed to generate a LiDAR derivative which will serve as a guide in mapping building footprints. The method utilizes several tools of a Geographic Information System (GIS) software called ArcGIS which can operate on physical attributes of buildings such as roofing curvature, slope and blueprint area in order to obtain the LiDAR derivative from LiDAR dataset. The method also uses an intermediary process called building removal process wherein buildings and other features lying below the defined minimum building height - 2 meters in the case of Phil-LiDAR 1 project - are removed. The building identification method was developed in the hope to hasten the identification of building features especially when orthophotographs and/or satellite imageries are not made available.
Reid, Kaydian S; Sekhobo, Jackson P; Gantner, Leigh A; Holbrook, MaryEllen K; Allsopp, Marie; Whalen, Linda B; Koren-Roth, Amy
2018-04-01
This study used a mixed-method, comparative case study approach to assess the level of capacity built for childhood obesity prevention among seven New York State Eat Well Play Hard-Community Projects (EWPH-CP). Data were collected through a self-reported survey in 2007, semi-structured interviews in 2009, and EWPH-CP program documentation throughout the 2006-2010 funding cycle. Quantitative and qualitative analyses were used along with an integrative framework for assessing local capacity building to characterize the capacity built by the study coalitions. Four coalitions rated membership characteristics as a challenge at the beginning of the funding cycle. Towards the end of the funding cycle, all seven coalitions reported activities that were initially focused on building their membership (i.e., member capacity) or positive working relationships (i.e. relational capacity), before eventually pursuing support and resources (i.e., organizational capacity) for implementing their chosen community-oriented programmatic goals (i.e., programmatic capacity). Five coalitions reported environmental changes aimed at increasing physical activity or fruit and vegetable intake. Technical assistance provided to coalitions was credited with contributing to the achievement of programmatic goals. These results suggest that the coalitions succeeded in building local capacity for increasing age-appropriate physical activity or fruit and vegetables intake in the target communities. Copyright © 2017 Elsevier Ltd. All rights reserved.
Gaining a Competitive Edge through Action Design Research
NASA Astrophysics Data System (ADS)
Alexa, L.; Alexa, M.; Avasilcăi, S.
2016-08-01
The current business environment is characterized by increased competition and highly innovative approach, in order to create products and services to better respond to the costumers’ needs and expectations. In this specific context, the research approaches need to be more flexible and business oriented and so, throughout the paper we have used a research method that combines design research and action research, named Action Design Research which is a research method used for generating prescriptive design knowledge through building and evaluating IT artifacts in an organizational setting [1]. Following the Action Design Research stages and principles: problem identification, building, intervention and evaluation, reflection and learning and formalization of learning, the research team has developed an online instrument used to actively involve the consumer in the product development process, in order to generate a better consumers insight regarding their needs and desires and to design and/or adjust the product accordingly. The customer engagement IT tool created and tested by using Action Design Research, E-PICUS, has been developed within the framework of the research project „E-solutions for innovation through customer pro-active involvement in value creation to increase organisational competitiveness (E-PICUS)”, PN- II-PT-PCCA-2013-4-1811, currently undergoing.
Augmented reality building operations tool
Brackney, Larry J.
2014-09-09
A method (700) for providing an augmented reality operations tool to a mobile client (642) positioned in a building (604). The method (700) includes, with a server (660), receiving (720) from the client (642) an augmented reality request for building system equipment (612) managed by an energy management system (EMS) (620). The method (700) includes transmitting (740) a data request for the equipment (612) to the EMS (620) and receiving (750) building management data (634) for the equipment (612). The method (700) includes generating (760) an overlay (656) with an object created based on the building management data (634), which may be sensor data, diagnostic procedures, or the like. The overlay (656) is configured for concurrent display on a display screen (652) of the client (642) with a real-time image of the building equipment (612). The method (700) includes transmitting (770) the overlay (656) to the client (642).
NASA Astrophysics Data System (ADS)
Ribera, Javier; Tahboub, Khalid; Delp, Edward J.
2015-03-01
Video surveillance systems are widely deployed for public safety. Real-time monitoring and alerting are some of the key requirements for building an intelligent video surveillance system. Real-life settings introduce many challenges that can impact the performance of real-time video analytics. Video analytics are desired to be resilient to adverse and changing scenarios. In this paper we present various approaches to characterize the uncertainty of a classifier and incorporate crowdsourcing at the times when the method is uncertain about making a particular decision. Incorporating crowdsourcing when a real-time video analytic method is uncertain about making a particular decision is known as online active learning from crowds. We evaluate our proposed approach by testing a method we developed previously for crowd flow estimation. We present three different approaches to characterize the uncertainty of the classifier in the automatic crowd flow estimation method and test them by introducing video quality degradations. Criteria to aggregate crowdsourcing results are also proposed and evaluated. An experimental evaluation is conducted using a publicly available dataset.