Labadie, Magali; O'Mahony, Elisabeth; Capaldo, Lise; Courtois, Arnaud; Lamireau, Thierry; Nisse, Patrick; Blanc-Brisset, Ingrid; Puskarczyk, Emmanuel
2017-12-13
Although the ingestion of button batteries is an infrequent situation, it leads to a significant risk of causing serious damage. This study was carried out to describe all the cases of button battery ingestion recorded by the French Poison Control Centers over 16 years. All the cases of button battery ingestion were recorded from 1 January 1999 to the end of June 2015, analysed (age, sex, number of ingested button batteries, clinical signs and treatments) and graded for severity according to the poisoning severity score. The incidence of button batteries ingestions was constant over the 16-year period, with an average of 266±98.5 cases per year and a total of 4030 cases. Nevertheless, 21 cases were severe and two deaths occurred. Interestingly, for the two patients who died, the battery was stuck in the oesophagus and they presented anorexia and/or dysphagia, abdominal pain and fever and in one case, a melena 3 weeks after ingestion. Importantly, these symptoms were observed even if the battery was expelled in one fatal case. Ingestions of button batteries still occur and may cause serious damage, especially in children, and if the button battery is stuck in the oesophagus as it might cause severe symptoms. Patients who have ingested a button battery must be directed to the emergency department for medical evaluation, even if the button battery has been expelled from the body and even more if gastrointestinal symptoms are present.
Liao, Wenjing; Wen, Guangyi; Zhang, Xiaowen
2015-06-01
Button batteries have been recognized as one of the dangerous foreign bodies to children for more than 30 years, but few related studies have been published to give more concern in China. We reported 6 cases of button battery intake as foreign body in children. The Chinese literature on button battery as foreign body in children was reviewed. The interval between the accidental ingestion and battery removal ranged from 6 hours to 3 days. Two patients had no sequela, 3 patients had tracheoesophageal fistulas, and 1 patient had nasal septal perforation. Twenty-eight articles about button battery as foreign body in children were obtained by Chinese-language literature searches including 25 case reports, 2 health education articles, and 1 imaging article. In total, 172 cases of button battery intake as foreign body in children were identified, 23 and 10 of the 159 cases involving nasal button battery lodgment developed nasal septal perforation and nasal adhesion, respectively. Tracheoesophageal fistula was identified in 4 of the 12 ingestion cases. One case of button battery intake was in external auditory canal. A small number of children with button battery as foreign body were reported in China, which is 1 of the biggest countries with large population of children.
The anesthetic management of button battery ingestion in children.
Ing, Richard J; Hoagland, Monica; Mayes, Lena; Twite, Mark
2018-03-01
Injuries related to button battery ingestion are common in children. This review provides an outline of the epidemiology, pathophysiology, management, and anesthetic implications in children who have ingested a button battery. A literature search was conducted in the United States National Library of Medicine PubMed database using the terms "button battery ingestion" and "children' and "removal" and "surgery" and "anesthesia". Ninety-six articles published in English were found from 1983-2017, and 62 of these articles were incorporated into this review. Additionally, the Internet was searched with the terms "button battery ingestion and children" to identify further entities, organizations, and resources affiliated with button battery ingestion in children. These additional sources were studied and included in this review. Button batteries are ubiquitous in homes and electronic devices. Since 2006, larger-diameter and higher-voltage batteries have become available. These are more likely to become impacted in the esophagus after ingestion and lead to an increase in severe morbidity and mortality due to caustic tissue injury. Children at the highest risk for complications are those under six years of age who have ingested batteries > 20 mm in diameter and sustain prolonged esophageal impaction at the level of the aortic arch with the negative pole oriented anteriorly. Anesthesiologists need to know about the epidemiology, pathophysiology, complications, and anesthetic management of children who have ingested button batteries.
Swallowing batteries ... These devices use button batteries: Calculators Cameras Hearing aids Penlights Watches ... If a person puts the battery up their nose and breathes it further in, ... problems Cough Pneumonia (if the battery goes unnoticed) ...
Serious complications after button battery ingestion in children.
Krom, Hilde; Visser, Margot; Hulst, Jessie M; Wolters, Victorien M; Van den Neucker, Anita M; de Meij, Tim; van der Doef, Hubert P J; Norbruis, Obbe F; Benninga, Marc A; Smit, Margot J M; Kindermann, Angelika
2018-07-01
Serious and fatal complications after button battery ingestion are increasing worldwide. The aim of this study is to describe serious complications after battery ingestion in children in the Netherlands.All pediatric gastroenterologists in the Netherlands performing upper endoscopies were asked to report all serious complications after battery ingestion in children (0-18 years) between 2008 and 2016 retrospectively.Sixteen serious complications were reported: death after massive bleeding through esophageal-aortal fistula (n = 1), esophageal-tracheal fistula (n = 5), stenosis after (suspected) perforation and mediastinitis (n = 5), (suspected) perforation and mediastinitis (n = 3), vocal cord paralysis (n = 1), and required reintubation for dyspnea and stridor (n = 1). The median time interval between ingestion and presentation was 5 (IQR 2-258) h. All children were ≤ 5 (median 1.4; IQR 0.9-2.1) years. Vomiting (31.3%), swallowing/feeding problems (31.3%), and fever (31.3%) were the most common presenting symptoms; however, 18.8% of the patients were asymptomatic (n = 1 missing). All batteries were button batteries (75% ≥ 20 mm; 18.8% < 20 mm; n = 1 missing). The batteries were removed by esophagogastroduodenoscopy (50%) and rigid endoscopy (37.5%) or surgically (12.5%). Sixteen serious complications occurred after small and large button batteries ingestion between 2008 and 2016 in both symptomatic and asymptomatic children in the Netherlands. Therefore, immediate intervention after (suspected) button battery ingestion is required. What is Known: • Button battery ingestion may result in serious and fatal complications. • Serious and fatal complications after button battery ingestion are increasing worldwide. What is New: • Sixteen serious complications after button battery ingestion occurred during 2008-2016 in children in the Netherlands. • Serious complications were also caused by small batteries (< 20 mm) in the Netherlands and also occurred in asymptomatic Dutch children.
Russell, Robert T; Griffin, Russell L; Weinstein, Elizabeth; Billmire, Deborah F
2014-09-01
The incidence of button battery ingestions is increasing and injury due to esophageal impaction begins within minutes of exposure. We changed our management algorithm for suspected button battery ingestions with intent to reduce time to evaluation and operative removal. A retrospective study was performed to identify and evaluate time to treatment and outcome for all esophageal button battery ingestions presenting to a major children's hospital emergency room from February 1, 2010 through February 1, 2012. During the first year, standard emergency room triage (ST) was used. During the second year, the triage protocol was changed and Trauma I triage (TT) was used. 24 children had suspected button battery ingestions with 11 having esophageal impaction. One esophageal impaction was due to 2 stacked coins. Time from arrival in emergency room to battery removal was 183minutes in ST group (n=4) and 33minutes in TT group (n=7) (p=0.04). One patient in ST developed a tracheoesophageal fistula. There were no complications in the TT group. The use of Trauma 1 activations for suspected button battery ingestions has led to more expedient evaluation and shortened time to removal of impacted esophageal batteries. Copyright © 2014 Elsevier Inc. All rights reserved.
Vascular ring complicates accidental button battery ingestion.
Mercer, Ronald W; Schwartz, Matthew C; Stephany, Joshua; Donnelly, Lane F; Franciosi, James P; Epelman, Monica
2015-01-01
Button battery ingestion can lead to dangerous complications, including vasculoesophageal fistula formation. The presence of a vascular ring may complicate battery ingestion if the battery lodges at the level of the ring and its important vascular structures. We report a 4-year-old boy with trisomy 21 who was diagnosed with a vascular ring at the time of button battery ingestion and died 9 days after presentation due to massive upper gastrointestinal bleeding from esophageal erosion and vasculoesophageal fistula formation. Copyright © 2015 Elsevier Inc. All rights reserved.
Eliason, Michael J; Melzer, Jonathan M; Winters, Jessica R; Gallagher, Thomas Q
2016-08-01
To complement a case series review of button battery impactions managed at our single military tertiary care center with a thorough literature review of laboratory research and clinical cases to develop a protocol to optimize patient care. Specifically, to identify predictive factors of long-term complications which can be used by the pediatric otolaryngologist to guide patient management after button battery impactions. A retrospective review of the Department of Defense's electronic medical record systems was conducted to identify patients with button battery ingestions and then characterize their treatment course. A thorough literature review complemented the lessons learned to identify potentially predictive clinical measures for long-term complications. Eight patients were identified as being treated for button battery impaction in the aerodigestive tract with two sustaining long-term complications. The median age of the patients treated was 33 months old and the median estimated time of impaction in the aerodigestive tract prior to removal was 10.5 h. Time of impaction, anatomic direction of the battery's negative pole, and identifying specific battery parameters were identified as factors that may be employed to predict sequelae. Based on case reviews, advancements in battery manufacturing, and laboratory research, there are distinct clinical factors that should be assessed at the time of initial therapy to guide follow-up management to minimize potential catastrophic sequelae of button battery ingestion. Published by Elsevier Ireland Ltd.
Esophageal button battery ingestion in children.
Şencan, Arzu; Genişol, İncinur; Hoşgör, Münevver
2017-07-01
Button battery lodged in the esophagus carries a high risk of morbidity and mortality. The purpose of this study was to present cases of patients with esophageal button battery ingestion treated at our clinic and to emphasize the importance of early diagnosis and treatment. Records of patients admitted to our hospital for foreign body ingestion between January 2010 and May 2015 were retrospectively reviewed. Cases with button battery lodged in the esophagus were included in the study. Patient data regarding age, sex, length of time after ingestion until admission, presenting clinical symptoms, type and localization of the battery, management, and prognosis were analyzed. Among 1891 foreign body ingestions, 71 were localized in the esophagus, and 8 of those (11.2%) were cases of button battery ingestion. Mean age was 1.7 years. Admission was within 6 hours of ingestion in 5 cases, after 24 hours had elapsed in 2, and 1 month after ingestion in 1 case. All patients but 1 knew the history of ingestion. Prompt endoscopic removal was performed for all patients. Three patients developed esophageal stricture, which responded to dilatation. Early recognition and timely endoscopic removal is mandatory in esophageal button battery ingestion. It should be suspected in the differential diagnosis of patients with persistent respiratory and gastrointestinal symptoms.
Nasal foreign bodies in children: should they have a plain radiograph in the accident and emergency?
Glynn, Fergal; Amin, Mohamed; Kinsella, John
2008-04-01
To determine the proportion of children with nasal foreign bodies who had button batteries as the foreign body. To describe the clinical care and outcome of those children with a button battery foreign body. A retrospective review of all children presenting to the accident and emergency room with a nasal foreign body or unilateral nasal discharge during a 6-month period was assessed. Forty-four children were included. The most common object found was a plastic bead (27%), followed by foam, paper, or tissue fragments (23%); food matter represented 15%. A button battery was found in 3 patients (7%); other foreign bodies included stones, buttons, crayons, erasers, and a pellet. Thiry-six (82%) had their foreign body removed without anesthetic and 8 (18%) required a general anesthetic. All 3 children with a button battery went undiagnosed until examination in the operating theater. Because there was no previous indication of the presence of a button battery in the 3 children, the removal of the foreign body under general anesthesia was scheduled for the following day. The removal of the button batteries would have been expedited had a plain radiograph been obtained, possibly resulting in less morbidity for our patients. We recommend a plain radiograph in all children presenting with a nonvisible foreign body or unilateral nasal discharge.
Moreno-Merino, Luis; Jiménez-Hernández, Maria Emilia; de la Losa, Almudena; Huerta-Muñoz, Virginia
2015-09-01
Many household batteries worldwide still end up in landfills or are incinerated due to inefficient collection and recycling schemes. Toxic heavy metals from improperly discarded button cells pose a serious risk to human health and the environment, as they can pollute air, soil and water. This paper analyses a series of button cells selected from batteries available on the retail market, and compares their polluting potential. A total of 64 batteries were subjected to chemical analyses of 19 elements - including metals and metalloids - , and energy density measurements. The samples were from four different brands of each of the four most common button cell technologies (alkaline, zinc-air, silver oxide and lithium). An energy-normalized index - the Weighted Potential Pollution Index (WPPI) - was proposed to compare the polluting potential of the different batteries. The higher the battery WPPI score, the greater the content in toxic elements and the lower the energy output. The results of the chemical composition and energy density varied depending on the construction technology of the button cells. However, significant differences in both variables were also found when comparing different brands within the same technology. The differences in WPPI values confirmed the existence of a significant margin to reduce the environmental impact of discarded button cells simply by avoiding the most polluting options. The choice of the battery with the most favourable WPPI produced a reduction in potential pollution of 3-53% for silver oxide batteries, 4-39% for alkaline, 20-28% for zinc-air and 12-26% for lithium. Comparative potential pollution could be assessed when selecting batteries using an energy-normalized index such as WPPI to reduce the environmental impact of improperly disposed button cells. Published by Elsevier B.V.
... Plants Foreign bodies such as watch or button batteries How you treat someone who may have been ... have applied medicated patches or swallowed a button battery. Call 911 or your local emergency number immediately ...
Button battery ingestion: the Greek experience and review of the literature.
Amanatidou, Virginia; Sofidiotou, Vassiliki; Fountas, Kostas; Kalostou, Angeliki; Tsamadou, Athina; Papathanassiou, Vassiliki; Neou, Polyxeni
2011-03-01
Foreign body ingestion is a common cause of admission in the pediatric emergency room. In the past, button batteries accounted for less than 2% of the foreign bodies ingested by small children, but in the last 2 decades, they show a rapidly increased frequency. The aim of the present study was to evaluate the potential risk after button battery ingestion in relation with the clinical manifestations and to perform a treatment-observation protocol in accordance with the international procedure. In a prospective observational analysis from November 2007 through February 2008, 31 cases of button battery ingestion were recorded by the Greek Poison Information Center. The interval between the accidental ingestion and first medical contact ranged from 5 minutes to 10 days. After initial evaluation including clinical examination and radiological localization of the foreign body, all cases were treated as outpatients. Reported complications included "black stools" in 9% and diarrhea in 3% of cases. In 1 case, the battery was endoscopically removed. The role of primary care physicians in informing the public about the potential danger of button battery digestion is crucial. Pediatricians should educate the parents about this hazard, as part of the routine guidelines for childproofing at home. Once again, prolepsis is the best policy.
Lahmar, J; Célérier, C; Garabédian, E N; Couloigner, V; Leboulanger, N; Denoyelle, F
2018-04-01
To study recent cases of esophageal injury due to button-battery ingestion in children presenting in pediatric ENT emergency departments of the Paris area of France (Île-de-France region), in order to propose appropriate preventive measures. A retrospective descriptive single-center study included all children under 15 years of age, presenting in pediatric ENT emergency departments between January 2008 and April 2014 for button-battery ingestion with esophageal impaction requiring emergency removal. Twenty-two boys and 4 girls, with a median age of 25 months, were included. Twenty-five of the 26 batteries had diameters of 20mm or more. Median esophageal impaction time was 7 hours 30 minutes (range, 2 to 72 hours). The complications rate was 23%. Mean hospital stay cost was €38,751 (range, €5130-119,737). The origin of the battery was known in 23 of the 26 cases: remote control without screw-secured compartment (42.3%), open battery pack (15.4%), children's toy (15.3%), camera (7.7%), watch (1 case) and hearing aid without screw-secured compartment (1 case). Esophageal lesions due to ingestion of button-batteries in children are almost always due to batteries larger than 20mm in diameter, mostly from devices with a poorly protected compartment, or batteries that are not individually packaged. These lesions cause serious complications in a quarter of cases and their management entails high health costs. Legislation requiring screw-secured compartments and individual blisters for batteries could have prevented 69.2% of the ingestions. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Pathophysiology of esophageal impairment due to button battery ingestion.
Völker, Johannes; Völker, Christine; Schendzielorz, Philipp; Schraven, Sebastian P; Radeloff, Andreas; Mlynski, Robert; Hagen, Rudolf; Rak, Kristen
2017-09-01
The increased use of button batteries with high energy densities in devices of daily life presents a high risk of injury, especially for toddlers and young children. If an accidental ingestion of a button battery occurs, this foreign body can become caught in the constrictions of the esophagus and cause serious damage to the adjacent tissue layers. The consequences can be ulcerations, perforations with fistula formation and damage to the surrounding anatomical structures. In order to gain a better understanding of the pathophysiology after ingestion, we carried out systematic studies on fresh preparations of porcine esophagi. The lithium button battery type CR2032, used most frequently in daily life, was exposed in preparations of porcine esophagi and incubated under the addition of artificial saliva at 37 °C. A total of eight esophagi were analysed by different methods. Measurements of the pH value around the battery electrodes and histological studies of the tissue damage were carried out after 0.5-24 h exposure time. In addition, macroscopic time-lapse images were recorded. Measurements of the battery voltage and the course of the electric current supplemented the experiments. The investigations showed that the batteries caused an electrolysis reaction in the moist environment. The positive electrode formed an acidic and the negative electrode a basic medium. Consequently, a coagulation necrosis at the positive pole, and a deep colliquation necrosis at the minus pole occurred. After an exposure time of 12 h, tissue damage caused by the lye corrosion was observed on the side of the negative electrode up to the lamina muscularis. The corrosion progressed up to the final exposure time of 24 h, but the batteries still had sufficient residual voltage, such that further advancing damage would be expected. Button battery ingestion in humans poses an acute life-threatening danger and immediate endoscopic removal of the foreign body is essential. After only 2 h exposure time, significant damage to the tissue could be detected, which progressed continuously to complete esophageal perforation. The primary prevention of battery ingestion is therefore of particular importance. Copyright © 2017 Elsevier B.V. All rights reserved.
Preventing battery ingestions: an analysis of 8648 cases.
Litovitz, Toby; Whitaker, Nicole; Clark, Lynn
2010-06-01
Outcomes of pediatric button battery ingestions have worsened substantially, predominantly related to the emergence of the 20-mm-diameter lithium cell as a common power source for household products. Button batteries lodged in the esophagus can cause severe tissue damage in just 2 hours, with delayed complications such as esophageal perforation, tracheoesophageal fistulas, exsanguination after fistulization into a major blood vessel, esophageal strictures, and vocal cord paralysis. Thirteen deaths have been reported. The objective of this study was to explore button battery ingestion scenarios to formulate prevention strategies. A total of 8648 battery ingestions that were reported to the National Battery Ingestion Hotline were analyzed. Batteries that were ingested by children who were younger than 6 years were most often obtained directly from a product (61.8%), were loose (29.8%), or were obtained from battery packaging (8.2%). Of young children who ingested the most hazardous battery, the 20-mm lithium cell, 37.3% were intended for remote controls. Adults most often ingested batteries that were sitting out, loose, or discarded (80.8%); obtained directly from a product (4.2%); obtained from battery packaging (3.0%); or swallowed within a hearing aid (12.1%). Batteries that were intended for hearing aids were implicated in 36.3% of ingestions. Batteries were mistaken for pills in 15.5% of ingestions, mostly by older adults. Parents and child care providers should be taught to prevent battery ingestions. Because 61.8% of batteries that were ingested by children were obtained from products, manufacturers should redesign household products to secure the battery compartment, possibly requiring a tool to open it.
Management of foreign body ingestions in children: button batteries and magnets.
Kodituwakku, Ronan; Palmer, Sarah; Paul, Siba Prosad
2017-04-27
Foreign body ingestion and foreign body aspiration commonly affect young children between 6 months and 6 years. A large number of these events remain unwitnessed and asymptomatic while the swallowed foreign body traverses the gastrointestinal tract and is passed in the stool. Recent literature has shown an increase in morbidity associated with button battery and (neomydium) magnet ingestions in children, particularly over the last decade. Early identification and management in a time critical manner is required in cases where button batteries get lodged in the oesophagus or multiple magnets are swallowed. Deaths, although rare, have been reported with these dangerous foreign body ingestions in children where diagnoses were delayed. Nurses through their direct contact with children in different clinical settings play a vital role in managing foreign body ingestions.
Imaging button battery ingestions and insertions in children: a 15-year single-center review.
Pugmire, Brian S; Lin, Tom K; Pentiuk, Scott; de Alarcon, Alessandro; Hart, Catherine K; Trout, Andrew T
2017-02-01
Recent studies have shown an increase in morbidity associated with button battery ingestions in children. To perform a comprehensive, imaging-focused review of all patients with confirmed button battery ingestions/insertions imaged at our institution in the last 15 years. Radiology reports from Jan. 1, 2000, to July 12, 2015, were searched for the terms "battery" and "batteries." Confirmed cases of battery ingestion/insertion for which images were available were reviewed. Cases were reviewed for imaging studies performed, imaging findings, patient demographics, clinical history and management. Two pediatric gastroenterologists reviewed endoscopic images and graded mucosal injuries in selected cases. Two hundred seventy-six cases were reviewed. All patients were imaged with radiography, 19 with fluoroscopy (6.8%), and 4 with CT (1.4%). Batteries retained in the esophagus (n = 27, 9.8%) were larger in diameter on average than those that had passed distally (22.1 ± 3.3 mm vs. 13.7 ± 1.6 mm, P<0.0001). Battery diameter ≥20 mm was associated with esophageal impaction (P<0.0001) and higher grade esophageal injury (P<0.0001). Mean battery diameter was greater for patients with grade 1 or higher mucosal injury than for patients with no mucosal injury (22.1 ± 2.1 mm vs. 14.7 ± 4.5 mm, P<0.0001). Sixteen percent (4/25) of patients with grade ≥1 esophageal injury had batteries in the stomach on initial imaging. Five patients (1.8%) had serious clinical complications (e.g., esophageal perforation, tracheoesophageal fistula). Button batteries >20mm in diameter warrant increased clinical scrutiny due to higher likelihood and severity of injury. Implementation of recent pediatric gastroenterology societal guidelines will likely lead to a substantial increase in the number of CT and MRI examinations.
Mercuric oxide may be found in some: Button batteries (batteries containing mercury are no longer sold in the ... long-term injury Any person who swallowed a battery will need immediate x-rays to make sure ...
Button battery injuries in the pediatric aerodigestive tract.
Ettyreddy, Abhinav R; Georg, Matthew W; Chi, David H; Gaines, Barbara A; Simons, Jeffrey P
2015-12-01
Children with a button battery impaction present with nonspecific symptoms that may account for a delay in medical care. We conducted a retrospective study of the clinical presentation, management, and complications associated with button battery ingestion in the pediatric aerodigestive tract and to evaluate the associated long-term morbidity. We reviewed the medical records of 23 patients who were treated for button battery impaction at our tertiary care children's hospital from Jan. 1, 2000, through July 31, 2013. This population was made up of 14 boys and 9 girls, aged 7 days to 12 years (mean: 4 yr). Patients were divided into three groups based on the site of impaction; there were 9 impactions in the esophagus and 7 each in the nasal cavity and stomach. We compiled information on the type and size of each battery, the duration of the impaction, presenting symptoms, treatment, and outcomes. The mean duration of battery impaction was 40.6, 30.7, and 21.0 hours in the esophagus, nasal cavity, and stomach, respectively. We were able to identify the specific type of battery in 13 cases; 11 of these cases (85%) involved a 3-V 20-mm lithium ion battery, including all cases of esophageal impaction in which the type of battery was identified. The most common presenting signs and symptoms were vomiting (n = 7 [30%]), difficulty feeding (n = 5 [22%]), cough (n = 5), and bloody nasal discharge (n = 5); none of the presenting signs and symptoms predicted the severity of the injury or the outcome. The median length of hospital stay was far greater in the esophageal group (12 days) than in the nasal and stomach groups (1 day each; p = 0.006). Battery impaction in the esophagus for more than 15 hours was associated with a significantly longer postoperative hospital stay than impaction for less than 15 hours (p = 0.04). Esophageal complications included strictures (n = 5), perforation (n = 3), and tracheoesophageal fistula formation (n = 2). Clinicians should consider battery impaction in the upper aerodigestive tract as an emergency that can lead to significant long-term morbidity, and therefore immediate surgical intervention is required.
Lakkireddy, Dhanunjaya; Knops, Reinoud; Atwater, Brett; Neuzil, Petr; Ip, John; Gonzalez, Elkin; Friedman, Paul; Defaye, Pascal; Exner, Derek; Aonuma, Kazutaka; Doshi, Rahul; Sperzel, Johannes; Reddy, Vivek
2017-12-01
The Nanostim leadless pacemaker (LP) met the primary endpoints in an investigational device exemption trial, and was shown to be fully retrievable percutaneously. In October 2016, St Jude Medical issued a worldwide alert of a battery malfunction that caused lost pacing output and LP communication. To report the battery failure mechanism and incidence and the worldwide patient management, including device retrieval experiences. The affected LP battery is a custom lithium-carbon monofluoride cell. These were returned after failure and underwent analysis assessing electronics and battery performance. Data were collected in ongoing clinical studies when LPs were abandoned or retrieved. Of 1423 LPs implanted worldwide, there were 34 battery failures, occurring at 2.9 ± 0.4 years with no instances of associated patient injury. Analysis of returned batteries revealed an increase in battery resistance caused by insufficient electrolyte availability at the cathode/anode interface. A total of 66 of 73 retrieval attempts were successful (90.4%; implant duration range: 0.2-4.0 years). The LP docking button was inaccessible in 6 patients, and the docking button detached from the LP during retrieval in 1 patient. There was 1 case of arteriovenous fistula and another case of the LP docking button migrating into the pulmonary artery. There were also 115 non-LP retrieval patients after the advisory who received an additional pacemaker, with no adverse device-to-device interactions reported. As with standard pacers, LPs can have critical battery failures. Chronic retrieval of LPs is safe and efficacious. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Soccorso, Giampiero; Grossman, Ole; Martinelli, Massimo; Marven, Sean S; Patel, Kirtik; Thomson, Mike; Roberts, Julian P
2012-08-01
Swallowed button batteries (BB) which remain lodged in the oesophagus are at risk of serious complications, particularly in young children. The authors report a 3-year-old child, who rapidly developed an oesophageal perforation, following the ingestion of a 20-mm lithium BB which was initially mistaken for a coin. A thoracotomy and T-tube management of the perforation led to a positive outcome. BBs (20 mm) in children should be removed quickly and close observation is required as the damage initiated by the battery can lead to a significant injury within a few hours.
Button Stopped button highlighted subbanner graphic: gray bar STOPPED When the vehicle is stopped engine when additional power is needed. It also acts as a generator, converting energy from the engine or engine instantly when needed. Main stage: See through car with battery, engine, and electric motor
Identification and topographic localization of metallic foreign bodies by metal detector.
Muensterer, Oliver J; Joppich, Ingolf
2004-08-01
Exact localization of ingested metal objects is necessary to guide therapy. This study prospectively evaluates the accuracy of foreign body (FB) identification and localization by metal detector (MTD) in a systematic topographic fashion. Patients who presented after an alleged or witnessed metal FB ingestion were scanned with an MTD. In case of a positive signal, the location was recorded in a topographic diagram, and radiographs were obtained. The diagnostic accuracy of the MTD scan for FB identification and topographic localization was determined by chi(2) analysis, and concordance was calculated by the McNemar test and expressed as kappa. A total of 70 MTD examinations were performed on 65 patients (age 6 months to 16 years); 5 patients were scanned twice on different days. The majority had swallowed coins and button batteries (n = 41). Of these, 29 items were correctly identified, and 11 of 12 were correctly ruled out (coins and button batteries: sensitivity, 100% [95% Confidence Interval 95% to 100%]; specificity, 91.7% [95% CI 76% to 100%], kappa = 0.94). When all metallic objects were included, 41 of 46 were correctly identified, and 22 of 24 were correctly ruled out (sensitivity, 89.1% [95% CI 80% to 98%]; specificity, 91.7% [95% CI 81% to 100%], kappa = 0.78). Five miscellaneous objects were not identified (sensitivity for items other than coins and button batteries 71% [95% CI 49% to 92%], kappa = 0.56). Localization by MTD was correct in 30 of 41 identified objects (73%). The error rates of junior and senior pediatric surgery residents did not differ significantly (P =.82). Ingested coins and button batteries can be safely and accurately found by metal detector. For these indications, the MTD is a radiation-free diagnostic alternative to conventional radiographs. Other items, however, cannot be ruled out reliably by MTD. In these cases, radiographic imaging is still indicated.
Disposable Electronic Cigarettes and Electronic Hookahs: Evaluation of Performance
Williams, Monique; Ghai, Sanjay
2015-01-01
Introduction: The purpose of this study was to characterize the performance of disposable button-activated and disposable airflow-activated electronic cigarettes (EC) and electronic hookahs (EH). Methods: The airflow rate required to produce aerosol, pressure drop, and the aerosol absorbance at 420nm were measured during smoke-outs of 9 disposable products. Three units of each product were tested in these experiments. Results: The airflow rates required to produce aerosol and the aerosol absorbances were lower for button-activated models (3mL/s; 0.41–0.55 absorbance) than for airflow-activated models (7–17mL/s; 0.48–0.84 absorbance). Pressure drop was also lower across button-activated products (range = 6–12mm H2O) than airflow-activated products (range = 15–67mm H20). For 25 of 27 units tested, airflow did not have to be increased during smoke-out to maintain aerosol production, unlike earlier generation models. Two brands had uniform performance characteristics for all parameters, while 3 had at least 1 product that did not function normally. While button-activated models lasted 200 puffs or less and EH airflow-activated models often lasted 400 puffs, none of the models produced as many puffs as advertised. Puff number was limited by battery life, which was shorter in button-activated models. Conclusion: The performance of disposable products was differentiated mainly by the way the aerosol was produced (button vs airflow-activated) rather than by product type (EC vs EH). Users needed to take harder drags on airflow-activated models. Performance varied within models, and battery life limited the number of puffs. Data suggest quality control in manufacturing varies among brands. PMID:25104117
Scholes, Melissa A; Jensen, Emily L
2016-09-01
To examine rates of otolaryngology intervention in children presenting to our emergency department with nasal foreign bodies, factors associated with otolaryngology involvement, rates of complications, and details on nasal button battery exposure. All patients presenting with a nasal foreign body to Children's Hospital Colorado from 2007 to 2012 were identified. Factors leading to referral to otolaryngology and operative intervention were examined, as well as complications. 102 patients were included. 36 (35%) patients were referred to the otolaryngology clinic, of which 58.9% required operating room intervention. 66 (64.7%) children had their nasal foreign bodies removed in the emergency room, however 30 (45%) of these were removed by an otolaryngology resident or attending physician. Overall, 64.7% of nasal foreign bodies required removal by otolaryngology. Of the 15 objects removed in the operating room, six were button batteries. No septal perforations occurred as a result of nasal button battery exposure. Multivariable logistic regression showed two significant predictors of OR removal: age and disc shaped objects. While emergency department providers are comfortable attempting removal of nasal foreign bodies, there was a high rate of otolaryngology intervention. Based on this data, there is a need to educate emergency room providers on nasal anatomy and techniques for nasal foreign body removal. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
[Behavioral phenotypes: cognitive and emotional explanation].
Pérez-Alvarez, F; Timoneda-Gallart, C
We present a series of Behavioural phenotypes treated with neurocognitive and neuroemotional procedure. A sample of 26 cases were selected according to qualitative methodology from neuropediatric patients. The method was based on using the PASS theory of intelligence to approach the cognitive problem and the theory of masquerade behaviour as self-defence to solve the emotional problem. Both theories have neurological bases. DN:CAS battery was utilized for assessment of cognitive processes. On the other hand, analysis of cases was carried out doing data analysis with video recorder device. All cases were considered responder cases although in different degree. The responder was defined as the patient which reached better intellectual achievement with respect to cognitive function and which gave up, at least partially, masquerade Behaviour with respect to emotional function. The Behaviour of the Behavioural phenotypes has neurological rationale. The PASS theory and the planning, in particular, supported by prefrontal cortex justifies consistently some behaviours. The masquerade Behaviour theory is explained by the fear emotional response mechanism which means emotion is a cerebral processing with neurological rationale. The Behavioural phenotypes are Behaviours and every Behaviour can be explained by neurological reasons both cognitive and emotional reasons. So, they can be treated by a cognitive and emotional procedure understood in the light of the neurology.
Foreign Body Ingestion in Children: Should Button Batteries in the Stomach Be Urgently Removed?
Lee, Jun Hee; Lee, Jee Hoo; Shim, Jung Ok; Lee, Jung Hwa; Eun, Baik-Lin; Yoo, Kee Hwan
2016-03-01
Foreign body (FB) ingestion is common in children, and button battery (BB) ingestion has been increasing in recent years. This study was to identify factors related to outcomes of FB ingestion, particularly BBs in the stomach. We evaluated whether the current recommendations are appropriate and aimed to suggest indications for endoscopic removal of BB in the stomach in young children. We investigated patient age, shape, size, location of FBs, spontaneous passage time and resulting complications among 76 children. We observed types, size, location of BB and outcomes, and analyzed their associations with complications. Coins and BB were the two most common FBs. Their shapes and sizes were not associated with the spontaneous passage time. Size, spontaneous passage time, and age were also not associated with any specific complications. For BB ingestion, all 5 cases with lithium batteries (≥1.5 cm, 3 V) presented moderate to major complications in the esophagus and stomach without any symptoms, even when the batteries were in the stomach and beyond the duodenum, while no complications were noted in 7 cases with alkaline batteries (<1.5 cm, 1.5 V) (p=0.001). All endoscopies were conducted within 24 hours after ingestion. The type and voltage of the battery should be considered when determining whether endoscopy is required to remove a BB in the stomach. For lithium battery ingestion in young children, urgent endoscopic removal might be important in order to prevent complications, even if the child is asymptomatic and the battery is smaller than 2 cm.
End User Acceptance - Requirements or Specifications, Certification, Testing
NASA Technical Reports Server (NTRS)
Jeevarajan, Judith
2013-01-01
NASA follows top level safety requirement of two-failure tolerance (t hree levels of controls or design for minimum risk) to all catastroph ic hazards in the design of safe li-ion batteries for space use. ? R igorous development testing at appropriate levels to credible offnominal conditions and review of test data. ? Implement robust design con trols based on test results and test again to confirm safety at the a ppropriate levels. ? Stringent testing of all (100%) flight batteries (from button cells to large batteries).
Aydin, Atakan; Aktas, Samil; Hafiz, Gunter; Kabakas, Fatih; Erer, Metin; Bilgic, Bilge
2004-07-01
Ingestion of button battery, if lodges in esophagus, causes mucosal destruction in esophagus and may damage surrounding tissues due to electrochemical reactions which may lead to esophagus perforation, tracheosefageal fistula and other serious problems. We designed an experimental study to test the effect of hyperbaric oxygen therapy on battery induced electrochemical tissue damage in the esophagus of a rabbit model and possible change with duration of contact time. Button batteries were inserted in esophagus of 40 rabbits which were divided into four groups. Groups 1 and 2 had 15 min of duration of contact time of battery in esophagus, while Groups 3 and 4 had 30 min. Groups 1 and 3 had hyperbaric oxygen therapy for 3 days; Groups 2 and 4 did not. At the end of 3rd day all animals were sacrified and samples were taken from the esophagus for determination of malondialdehyde levels and for histopathological examination to compare: mucosal destruction, muscular layer involvement, perforation and tracheal involvement between groups. Malondialdehyde levels, mucosal destruction, muscular layer involvement, perforation and tracheal involvement were significantly higher in groups which had 30 min of contact time compared to groups which had 15 min. The same assessments were significantly higher in Group 1 (15 min of contact time with hyperbaric oxygen therapy) compared to Group 2 (15 min of contact time without hyperbaric oxygen therapy). However, the difference between Group 3 (30 min of contact time with hyperbaric oxygen therapy) and Group 4 (30 min of contact time, no hyperbaric oxygen therapy) was not significant. Our study demonstrated that if contact time is 15 min HBO had an additive adverse effect to electrochemically burned esophagus by increasing free radicals and eventually tissue damage. However, if the contact time is 30 min its adverse effect is shielded by huge electrochemical destruction due to long contact time.
Button Cell Battery Safety Act of 2011
Sen. Rockefeller, John D., IV [D-WV
2011-06-09
Senate - 06/09/2011 Read twice and referred to the Committee on Commerce, Science, and Transportation. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:
Access to Button Cell Batteries Act of 2010
Sen. Goodwin, Carte Patrick [D-WV
2010-09-29
Senate - 09/29/2010 Read twice and referred to the Committee on Commerce, Science, and Transportation. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:
Oral Exposure of a Child to a Lithium Ion Battery.
Townsend, Janice A; Curran, Ronald
2016-01-01
Battery exposure has the potential for severe morbidity and possible mortality. Accidental exposure is rising with the increased use of button batteries, and young children and older adults are at highest risk for accidental exposure. The purpose of this paper is to report a case of mouth exposure to a lithium ion battery in a boy. A review of the current literature on incidence, diagnosis, and outcomes of battery exposure is presented. When symptoms such as diarrhea, vomiting, and abdominal distress of non-specific origin are present, battery ingestion should be included in the differential diagnosis. Dentists may be the first health professionals to encounter battery exposure, especially in the case of mouth exposures. Knowledge of signs and symptoms are necessary to properly diagnose and refer for medical management.
... such as marbles), crayon pieces, erasers, paper wads, cotton, beads, button batteries, and disc magnets. A foreign ... DO NOT search the nose with cotton swabs or other tools. This may ... into the nose. DO NOT use tweezers or other tools to remove ...
NASA Technical Reports Server (NTRS)
LaPeyronnie, Glenn M. (Inventor); Huff, Charles M. (Inventor)
2010-01-01
The present invention provides a testing apparatus and method for testing the adhesion of a coating to a surface. The invention also includes an improved testing button or dolly for use with the testing apparatus and a self aligning button hook or dolly interface on the testing apparatus. According to preferred forms, the apparatus and method of the present invention are simple, portable, battery operated rugged, and inexpensive to manufacture and use, are readily adaptable to a wide variety of uses, and provide effective and accurate testing results. The device includes a linear actuator driven by an electric motor coupled to the actuator through a gearbox and a rotatable shaft. The electronics for the device are contained in the head section of the device. At the contact end of the device, is positioned a self aligning button hook, attached below the load cell located on the actuator shaft.
Rowland, Diane; DiGuiseppi, Carolyn; Roberts, Ian; Curtis, Katherine; Roberts, Helen; Ginnelly, Laura; Sculpher, Mark; Wade, Angela
2002-01-01
Objectives To identify which type of smoke alarm is most likely to remain working in local authority inner city housing, and to identify an alarm tolerated in households with smokers. Design Randomised controlled trial. Setting Two local authority housing estates in inner London. Participants 2145 households. Intervention Installation of one of five types of smoke alarm (ionisation sensor with a zinc battery; ionisation sensor with a zinc battery and pause button; ionisation sensor with a lithium battery and pause button; optical sensor with a lithium battery; or optical sensor with a zinc battery). Main outcome measure Percentage of homes with any working alarm and percentage in which the alarm installed for this study was working after 15 months. Results 54.4% (1166/2145) of all households and 45.9% (465/1012) of households occupied by smokers had a working smoke alarm. Ionisation sensor, lithium battery, and there being a smoker in the household were independently associated with whether an alarm was working (adjusted odds ratios 2.24 (95% confidence interval 1.75 to 2.87), 2.20 (1.77 to 2.75), and 0.62 (0.52 to 0.74)). The most common reasons for non-function were missing battery (19%), missing alarm (17%), and battery disconnected (4%). Conclusions Nearly half of the alarms installed were not working when tested 15 months later. Type of alarm and power source are important determinants of whether a household had a working alarm. What is already known on this topicFunctioning smoke alarms can reduce the risk of death in the event of a house fireMany local authorities install smoke alarms in their propertiesSeveral different types of smoke alarm are availableWhat this study addsOnly half of the smoke alarms installed in local authority housing were still working 15 months laterIonising smoke alarms with long life lithium batteries were most likely to remain functioningInstalling smoke alarms may not be an effective use of resources PMID:12411356
Further miniaturisation of the Thermochron iButton to create a thermal bio-logger weighing 0.3 g.
Virens, Josef; Cree, Alison
2018-06-05
Thermochron iButtons are commonly used by thermal biologists to continuously measure body temperature from animals. However, if unmodified, these devices are of a size that limits their use with very small animals. To allow iButtons to be used to study smaller species, methods to miniaturise them by 61% have been previously described. We present a method to reduce iButton mass by a further 71%. The modified devices have a shorter battery life, but the minimum size of vertebrates able to carry the devices is reduced from 28.9 g to 6.6 g, if the arbitrary, yet widely cited, maximum of 5% body mass for attached devices is adhered to. We demonstrate the application of our method by recording surface temperatures of captive and wild skinks and show that captive cockroaches weighing 0.8 g are also able to carry the device. We believe this to be the first time that temperature data have been recorded from an insect in this way. © 2018. Published by The Company of Biologists Ltd.
Lithium-ion batteries for hearing aid applications. II. Pulse discharge and safety tests
NASA Astrophysics Data System (ADS)
Passerini, S.; Coustier, F.; Owens, B. B.
Rechargeable lithium-ion batteries were designed to meet the power requirements of hearing aid devices (HADs). The batteries were designed in a 312-button cell size, compatible with existing hearing aids. The batteries were tested to evaluate the design and the electrochemical performance, as they relate to a typical hearing aid application. The present report covers the pulse capabilities, cycle life and preliminary safety tests. The results are compared with other battery chemistries: secondary lithium-alloy and nickel-metal hydride batteries and primary Zn-air batteries. The cell AC impedance was stable over the frequency range between 1 and 50 kHz, ranging between 5 Ω at the higher frequency and 12 Ω at the lower extreme. Pulse tests were consistent with these values, as the cells were capable of providing a series of 100 mA pulses of 10-s duration. The safety tests suggest that the design is intrinsically safe with respect to the most common types of abuse conditions.
Safe Energy Source in Battery-operated Toys for Children.
Rossi, Alfredo; Vignola, Silvia; Nason, Francesca; Boschetti, Federica; Bramerio, Manuela; Bailini, Alessandro; Pinarello, Giordano
2017-11-01
Serious and even fatal consequences of disk batteries ingestion in children are well known. Among other applications, disk batteries are used to power small toys, from which they can be unexpectedly extracted and swallowed. We tested a new cell intended for little toys (green cell [GC]), after 6 and 12 hours of in vitro close contact with esophageal swine mucosa. The GC was compared with lithium and silver button batteries under the same experimental conditions. Tissues in contact with the GC did not show pH variations nor histological alterations after 6 and 12 hours. In such conditions, statistically significant differences were found between the GC and the lithium and silver batteries. So far, multidisciplinary medical effort has been driven to both emergency approach and subsequent operative strategies in children with ingested batteries. Our trial demonstrates the possibility to primarily prevent battery-induced damages by designing new-generation safe cells with no tissue toxicity to power little toys intended for children.
Survey of mercury, cadmium and lead content of household batteries.
Recknagel, Sebastian; Radant, Hendrik; Kohlmeyer, Regina
2014-01-01
The objective of this work was to provide updated information on the development of the potential impact of heavy metal containing batteries on municipal waste and battery recycling processes following transposition of the new EU Batteries Directive 2006/66/EC. A representative sample of 146 different types of commercially available dry and button cells as well as lithium-ion accumulators for mobile phones were analysed for their mercury (Hg)-, cadmium (Cd)- and lead (Pb)-contents. The methods used for preparing the cells and analysing the heavy metals Hg, Cd, and Pb were either developed during a former study or newly developed. Several batteries contained higher mass fractions of mercury or cadmium than the EU limits. Only half of the batteries with mercury and/or lead fractions above the marking thresholds were labelled. Alkaline-manganese mono-cells and Li-ion accumulators, on average, contained the lowest heavy metal concentrations, while zinc-carbon batteries, on average, contained the highest levels. Copyright © 2013 Elsevier Ltd. All rights reserved.
Smoke alarm tests may not adequately indicate smoke alarm function.
Peek-Asa, Corinne; Yang, Jingzhen; Hamann, Cara; Young, Tracy
2011-01-01
Smoke alarms are one of the most promoted prevention strategies to reduce residential fire deaths, and they can reduce residential fire deaths by half. Smoke alarm function can be measured by two tests: the smoke alarm button test and the chemical smoke test. Using results from a randomized trial of smoke alarms, we compared smoke alarm response to the button test and the smoke test. The smoke alarms found in the study homes at baseline were tested, as well as study alarms placed into homes as part of the randomized trial. Study alarms were tested at 12 and 42 months postinstallation. The proportion of alarms that passed the button test but not the smoke test ranged from 0.5 to 5.8% of alarms; this result was found most frequently among ionization alarms with zinc or alkaline batteries. These alarms would indicate to the owner (through the button test) that the smoke alarm was working, but the alarm would not actually respond in the case of a fire (as demonstrated by failing the smoke test). The proportion of alarms that passed the smoke test but not the button test ranged from 1.0 to 3.0%. These alarms would appear nonfunctional to the owner (because the button test failed), even though the alarm would operate in response to a fire (as demonstrated by passing the smoke test). The general public is not aware of the potential for inaccuracy in smoke alarm tests, and burn professionals can advocate for enhanced testing methods. The optimal test to determine smoke alarm function is the chemical smoke test.
Hidden attraction: a menacing meal of magnets and batteries.
Brown, Julie C; Murray, Karen F; Javid, Patrick J
2012-08-01
Magnet and button battery ingestions are increasingly common, and can result in significant morbidity. Timely identification of hazardous foreign body ingestions can be difficult in non-verbal and non-disclosing children. We aim to present a case that demonstrates some of the challenges around identifying and correctly locating magnets and batteries, and the importance of prompt identification and removal. We describe an older child with the covert ingestion of multiple magnets and batteries, with magnets that attracted across the stomach and a loop of jejunum. Mild symptoms and signs resulted in a delayed diagnosis and serious consequences. Radiographs suggested a gastric location of the foreign bodies. Health care workers should consider the possibility of battery or magnet ingestions in children with vomiting and abdominal pain, even when well-appearing. Like esophageal batteries, multiple gastrointestinal magnets and combined magnet-battery ingestions can cause significant morbidity, and prompt identification is important. Providers should ask verbal children for ingestion histories, and consider radiographs when symptoms are atypical or persistent. Like esophageal batteries, gastrointestinal magnet-battery ingestions should be removed promptly to prevent complications. Caregivers should supervise or limit the use of toys that include magnets and batteries. Copyright © 2012 Elsevier Inc. All rights reserved.
Survey of mercury, cadmium and lead content of household batteries
DOE Office of Scientific and Technical Information (OSTI.GOV)
Recknagel, Sebastian, E-mail: sebastian.recknagel@bam.de; Radant, Hendrik; Kohlmeyer, Regina
2014-01-15
Highlights: • A well selected sample of 146 batteries was analysed for its heavy metals content. • A comparison was made between heavy metals contents in batteries in 2006 and 2011. • No significant change after implementation of the new EU Batteries Directive. • Severe differences in heavy metal contents were found in different battery-types. - Abstract: The objective of this work was to provide updated information on the development of the potential impact of heavy metal containing batteries on municipal waste and battery recycling processes following transposition of the new EU Batteries Directive 2006/66/EC. A representative sample of 146more » different types of commercially available dry and button cells as well as lithium-ion accumulators for mobile phones were analysed for their mercury (Hg)-, cadmium (Cd)- and lead (Pb)-contents. The methods used for preparing the cells and analysing the heavy metals Hg, Cd, and Pb were either developed during a former study or newly developed. Several batteries contained higher mass fractions of mercury or cadmium than the EU limits. Only half of the batteries with mercury and/or lead fractions above the marking thresholds were labelled. Alkaline–manganese mono-cells and Li-ion accumulators, on average, contained the lowest heavy metal concentrations, while zinc–carbon batteries, on average, contained the highest levels.« less
Generating a Corpus of Mobile Forensic Images for Masquerading user Experimentation.
Guido, Mark; Brooks, Marc; Grover, Justin; Katz, Eric; Ondricek, Jared; Rogers, Marcus; Sharpe, Lauren
2016-11-01
The Periodic Mobile Forensics (PMF) system investigates user behavior on mobile devices. It applies forensic techniques to an enterprise mobile infrastructure, utilizing an on-device agent named TractorBeam. The agent collects changed storage locations for later acquisition, reconstruction, and analysis. TractorBeam provides its data to an enterprise infrastructure that consists of a cloud-based queuing service, relational database, and analytical framework for running forensic processes. During a 3-month experiment with Purdue University, TractorBeam was utilized in a simulated operational setting across 34 users to evaluate techniques to identify masquerading users (i.e., users other than the intended device user). The research team surmises that all masqueraders are undesirable to an enterprise, even when a masquerader lacks malicious intent. The PMF system reconstructed 821 forensic images, extracted one million audit events, and accurately detected masqueraders. Evaluation revealed that developed methods reduced storage requirements 50-fold. This paper describes the PMF architecture, performance of TractorBeam throughout the protocol, and results of the masquerading user analysis. © 2016 American Academy of Forensic Sciences.
A material flow of lithium batteries in Taiwan.
Chang, T C; You, S J; Yu, B S; Yao, K F
2009-04-30
Li batteries, including secondary and cylindrical/button primary Li batteries, are used worldwide in computers, communications and consumer electronics products. However, there are several dangerous issues that occur during the manufacture, shipping, and storage of Li batteries. This study analyzes the material flow of lithium batteries and their valuable heavy metals in Taiwan for the year 2006 by material flow analysis. According to data from the Taiwan Environmental Protection Administration, Taiwan External Trade Development Council, Bureau of Foreign Trade, Directorate General of Customs, and the Li batteries manufactures/importers/exporters. It was found that 2,952,696 kg of Li batteries was input into Taiwan for the year 2006, including 2,256,501 kg of imported Li batteries and 696,195 kg of stock Li batteries in 2005. In addition, 1,113,867 and 572,215 kg of Li batteries was domestically produced and sold abroad, revealing that 3,494,348 kg of different types of Li batteries was sold in Taiwan. Of these domestically sold batteries, 504,663 and 146,557 kg were treated domestically and abroad. Thus, a total of 2,843,128 kg of Li batteries was stored by individual/industry users or illegally disposed. In addition, it was also observed that 2,120,682 kg of heavy metals contained in Li batteries, including Ni, Co, Al, Cu and Ni, was accumulated in Taiwan, with a recycled value of 38.8 million USD. These results suggest that these heavy metals should be recovered by suitable collection, recycling and reuse procedures.
Jatana, Kris R; Rhoades, Keith; Milkovich, Scott; Jacobs, Ian N
2017-06-01
Button battery (BB) injuries continue to be a significant source of morbidity and mortality, and there is a need to confirm the mechanism of injury for development of additional mitigation strategies. Cadaveric piglet esophageal model. Lithium, silver oxide, alkaline, and zinc-air BBs were placed in thawed sections of cadaveric piglet esophagus, bathed in normal saline. Severity of gross visual burn, pH, and temperature were recorded every 30 minutes for 6 hours. In other esophageal tissue specimens, the lithium BB was removed after 24, 36, and 48 hours and the site was irrigated with either 0.25% or 3% acetic acid. Separately, ReaLemon® juice, orange juice, Coke®, Dasani® water, Pepsi®, and saline were infused over a vertically suspended esophagus with a CR2032 lithium battery every 5 minutes for 2 hours while tissue temperature and pH were measured. A gradual rise in tissue pH and minimal change in temperature was noted for all BBs. ReaLemon® and orange juice applied every 5 minutes were most effective at neutralization of tissue pH with minimal change in tissue temperature. After BB removal (24, 36, 48 hours), irrigation of esophageal tissue specimens with 50-150 mL 0.25% acetic acid neutralized the highly alkaline tissue pH. BB appear to cause an isothermic hydrolysis reaction resulting in an alkaline caustic injury. Potential new mitigation strategies include application of neutralizing weakly acidic solutions that may reduce esophageal injury progression. NA Laryngoscope, 127:1276-1282, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.
Pediatric Toxicology: Household Product Ingestions.
O'Donnell, Katherine A
2017-12-01
Nonpharmaceutical household products are the most common substances involved in exploratory ingestions in young children. Fortunately, most of these products are not toxic if ingested in small volumes. However, there are several household products that have the potential to cause significant toxicity and, rarely, fatalities in young children. Key products reviewed in this article include alcohols, button batteries, corrosive cleaning products, laundry detergent pods, hydrocarbons, and magnets. [Pediatr Ann. 2017;46(12):e449-e453.]. Copyright 2017, SLACK Incorporated.
A Keyboard for Underwater Performance Assessment Battery Testing
1990-11-08
Applied Engineering . This four button underwater keyboard uses only a small portion of the boards capacity. The cable is connected to the I/O 32 board via a...H.O., by Applied Engineering ) require special programming to work with the IO 32 board. If the boards are accessed directly from Apple Basic with the... Applied Engineering , 1988) is presented in the Appendix. This program will work with either the enhanced or the unenhanced version of the Apple lie. 6
Cursor Control Device Test Battery
NASA Technical Reports Server (NTRS)
Holden, Kritina; Sandor, Aniko; Pace, John; Thompson, Shelby
2013-01-01
The test battery was developed to provide a standard procedure for cursor control device evaluation. The software was built in Visual Basic and consists of nine tasks and a main menu that integrates the set-up of the tasks. The tasks can be used individually, or in a series defined in the main menu. Task 1, the Unidirectional Pointing Task, tests the speed and accuracy of clicking on targets. Two rectangles with an adjustable width and adjustable center- to-center distance are presented. The task is to click back and forth between the two rectangles. Clicks outside of the rectangles are recorded as errors. Task 2, Multidirectional Pointing Task, measures speed and accuracy of clicking on targets approached from different angles. Twenty-five numbered squares of adjustable width are arranged around an adjustable diameter circle. The task is to point and click on the numbered squares (placed on opposite sides of the circle) in consecutive order. Clicks outside of the squares are recorded as errors. Task 3, Unidirectional (horizontal) Dragging Task, is similar to dragging a file into a folder on a computer desktop. Task 3 requires dragging a square of adjustable width from one rectangle and dropping it into another. The width of each rectangle is adjustable, as well as the distance between the two rectangles. Dropping the square outside of the rectangles is recorded as an error. Task 4, Unidirectional Path Following, is similar to Task 3. The task is to drag a square through a tunnel consisting of two lines. The size of the square and the width of the tunnel are adjustable. If the square touches any of the lines, it is counted as an error and the task is restarted. Task 5, Text Selection, involves clicking on a Start button, and then moving directly to the underlined portion of the displayed text and highlighting it. The pointing distance to the text is adjustable, as well as the to-be-selected font size and the underlined character length. If the selection does not include all of the underlined characters, or includes non-underlined characters, it is recorded as an error. Task 6, Multi-size and Multi-distance Pointing, presents the participant with 24 consecutively numbered buttons of different sizes (63 to 163 pixels), and at different distances (60 to 80 pixels) from the Start button. The task is to click on the Start button, and then move directly to, and click on, each numbered target button in consecutive order. Clicks outside of the target area are errors. Task 7, Standard Interface Elements Task, involves interacting with standard interface elements as instructed in written procedures, including: drop-down menus, sliders, text boxes, radio buttons, and check boxes. Task completion time is recorded. In Task 8, a circular track is presented with a disc in it at the top. Track width and disc size are adjustable. The task is to move the disc with circular motion within the path without touching the boundaries of the track. Time and errors are recorded. Task 9 is a discrete task that allows evaluation of discrete cursor control devices that tab from target to target, such as a castle switch. The task is to follow a predefined path and to click on the yellow targets along the path.
Fluoroscopy-Guided Endoscopic Removal of Foreign Bodies.
Kim, Junhwan; Ahn, Ji Yong; So, Seol; Lee, Mingee; Oh, Kyunghwan; Jung, Hwoon-Yong
2017-03-01
In most cases of ingested foreign bodies, endoscopy is the first treatment of choice. Moreover, emergency endoscopic removal is required for sharp and pointed foreign bodies such as animal or fish bones, food boluses, and button batteries due to the increased risks of perforation, obstruction, and bleeding. Here, we presented two cases that needed emergency endoscopic removal of foreign bodies without sufficient fasting time. Foreign bodies could not be visualized by endoscopy due to food residue; therefore, fluoroscopic imaging was utilized for endoscopic removal of foreign bodies in both cases.
2012-12-01
GPS receiver, the Ashtech ProMark 500; a 3.4-GHz radio modem, the FreeWave 3400-SMR; a display unit, the Magellan MobileMapper CX; a 12-V battery pack...Figure 8. Bottom view of the ProMark 500. 3.1 Survey Unit RTK GPS Setup The following are the procedures for setting up...the RTK GPS Survey Unit: 1. Connect the radio modem to the ProMark 500 with serial cable #7 and #8. Display Screen Scroll Button Power LED Log
Severe depression masquerading as Creutzfeldt-Jakob disease
Shiner, Elizabeth; Taylor, Lauren; Mohan, Adith; Watson, Shaun; Sachdev, Perminder Singh
2014-01-01
We report a case of melancholic depression with catatonic features presenting as a rapidly progressive organic brain syndrome, initially thought to be probable Creutzfeldt-Jakob disease. The case highlights the fundamental importance of thorough exclusion of treatable pathology masquerading as an irreversible syndrome. PMID:24748140
Mexican American Male Masquerades in the Institution as Bully
ERIC Educational Resources Information Center
Oesterreich, Heather A.; Sosa-Provencio, Mia A.; Anatska, Tamara
2017-01-01
This Black and Chicana Feminist case study challenges national discourse surrounding school bullying as individualistic, student-centered. We explore the warrior lens of Mexican/Mexican-American males. While masquerading institutional compliance, they simultaneously unmask policies, practices as the means to control mind/bodies/spirit. This…
Al13-pillared anatase TiO2 as a cathode for a lithium battery
NASA Astrophysics Data System (ADS)
Sun, X. D.; Ma, C. L.; Wang, Y. D.; Li, H. D.
2004-11-01
Al13-pillared anatase TiO2 is used as a cathode of a lithium battery for the first time. First, a layered titanium dioxide with cationic surfactant ions of cetyltrimethylammonium (CTA+) in the interlayers is synthesized by self-assembly. Then, pillared TiO2 is obtained by exchange of polyoxo cations of aluminium, [Al13O4(OH)24(H2O)12]7+, with CTA+ and subsequent calcination at 300 °C for 1 h in the air. Powder x-ray diffraction (XRD), transmission electron microscopy (TEM) and surface area (BET) methods are used to characterize the layered and pillared forms of titanium dioxide. A lithium battery with the Al13-pillared TiO2 as the cathode and Li metal foil as the anode is studied within the 1-2.2 V voltage range. The specific capacity of the closed button cell (size 2025) that is delivered on the initial discharge reached 191.4 mA h g-1 at the rate of 25 mA g-1. The cell shows good cycling performance over 50 cycles.
An introduction to the Micrel Micropump MP Daily portable syringe driver.
Groves, Karen E
2003-11-01
In this article the author describes the Micrel Micropump MP Daily (MP Daily) portable syringe driver. This follows the author's experience of a 4-month pilot of the device by an inpatient palliative care unit. Portable syringe drivers are commonly used to deliver continuous subcutaneous infusions in palliative care situations. Those in current use are not without problems and serious adverse events have occasionally been reported, mainly resulting from confusion between models. The MP Daily syringe driver addresses some of these issues while remaining small, lightweight and inexpensive, with a long battery life and fitting into the pocket of a shirt of pyjama jacket. Improvements over current models include an on/off button, the absence of facilities to set a zero rate or change the rate once the syringe driver is running, and the absence of a boost button. In addition, there are improved alarms, a message display system and a configuration menu. Although confusion remains a problem, and the ideal has not yet been reached, the MP Daily goes some considerable way towards reducing risks and opportunities for human error.
Facile and Nonradiation Pretreated Membrane as a High Conductive Separator for Li-Ion Batteries.
Li, Bao; Li, Yongjun; Dai, Dongmei; Chang, Kun; Tang, Hongwei; Chang, Zhaorong; Wang, Chunru; Yuan, Xiao-Zi; Wang, Haijiang
2015-09-16
Polyolefin membranes are widely used as separators in commercialized Li-ion batteries. They have less polarized surfaces compared with polarized molecules of electrolyte, leading to a poor wetting state for separators. Radiation pretreatments are often adopted to solve such a problem. Unfortunately, they can only activate several nanometers deep from the surface, which limits the performance improvement. Here we report a facile and scalable method to polarize polyolefin membranes via a chemical oxidation route. On the surfaces of pretreated membrane, layers of poly(ethylene oxide) and poly(acrylic acid) can easily be coated, thus resulting in a high Li-ion conductivity of the membrane. Assembled with this decorated separator in button cells, both high-voltage (Li1.2Mn0.54Co0.13Ni0.13O2) and moderate-voltage (LiFePO4) cathode materials show better electrochemical performances than those assembled with pristine polyolefin separators.
USDA-ARS?s Scientific Manuscript database
To avoid detection by predators, many herbivorous insects have evolved an astonishing degree of visual fidelity to inanimate items in their surroundings that renders them cryptic to their enemies. In an evolutionary twist to crypsis, known as masquerade, a predator detects prey, but fails to perceiv...
Harper, Martin; Pacolay, Bruce; Hintz, Patrick; Andrew, Michael E
2006-03-01
Personal and area samples for airborne lead were taken at a lead mine concentrator mill, and at a lead-acid battery recycler. Lead is mined as its sulfidic ore, galena, which is often associated with zinc and silver. The ore typically is concentrated, and partially separated, on site by crushing and differential froth flotation of the ore minerals before being sent to a primary smelter. Besides lead, zinc and iron are also present in the airborne dusts, together with insignificant levels of copper and silver, and, in one area, manganese. The disposal of used lead-acid batteries presents environmental issues, and is also a waste of recoverable materials. Recycling operations allow for the recovery of lead, which can then be sold back to battery manufacturers to form a closed loop. At the recycling facility lead is the chief airborne metal, together with minor antimony and tin, but several other metals are generally present in much smaller quantities, including copper, chromium, manganese and cadmium. Samplers used in these studies included the closed-face 37 mm filter cassette (the current US standard method for lead sampling), the 37 mm GSP or "cone" sampler, the 25 mm Institute of Occupational Medicine (IOM) inhalable sampler, the 25 mm Button sampler, and the open-face 25 mm cassette. Mixed cellulose-ester filters were used in all samplers. The filters were analyzed after sampling for their content of the various metals, particularly lead, that could be analyzed by the specific portable X-ray fluorescence (XRF) analyzer under study, and then were extracted with acid and analyzed by inductively coupled plasma optical emission spectroscopy (ICP-OES). The 25 mm filters were analyzed using a single XRF reading, while three readings on different parts of the filter were taken from the 37 mm filters. For lead at the mine concentrate mill, all five samplers gave good correlations (r2 > 0.96) between the two analytical methods over the entire range of found lead mass, which encompassed the permissible exposure limit of 150 mg m(-3) enforced in the USA by the Mine Safety and Health Administration (MSHA). Linear regression on the results from most samplers gave almost 1 ratio 1 correlations without additional correction, indicating an absence of matrix effects from the presence of iron and zinc in the samples. An approximately 10% negative bias was found for the slope of the Button sampler regression, in line with other studies, but it did not significantly affect the accuracy as all XRF results from this sampler were within 20% of the corresponding ICP values. As in previous studies, the best results were obtained with the GSP sampler using the average of three readings, with all XRF results within 20% of the corresponding ICP values and a slope close to 1 (0.99). Greater than 95% of XRF results were within 20% of the corresponding ICP values for the closed-face 37 mm cassette using the OSHA algorithm, and the IOM sampler using a sample area of 3.46 cm2. As in previous studies, considerable material was found on the interior walls of all samplers that possess an internal surface for deposition, at approximately the same proportion for all samplers. At the lead-acid battery recycler all five samplers in their optimal configurations gave good correlations (r2 > 0.92) between the two analytical methods over the entire range of found lead mass, which included the permissible exposure limit enforced in the USA by the Occupational Safety and Health Administration (OSHA). Linear regression on the results from most samplers gave almost 1 ratio 1 correlations (except for the Button sampler), indicating an absence of matrix effects from the presence of the smaller quantities of the other metals in the samples. A negative bias was found for the slope of the button sampler regression, in line with other studies. Even though very high concentrations of lead were encountered (up to almost 6 mg m(-3)) no saturation of the detector was observed. Most samplers performed well, with >90% of XRF results within +/- 25% of the corresponding ICP results for the optimum configurations. The OSHA algorithm for the CFC worked best without including the back-up pad with the filter.
Bigum, Marianne; Petersen, Claus; Christensen, Thomas H; Scheutz, Charlotte
2013-11-01
A total of 26.1Mg of residual waste from 3129 households in 12 Danish municipalities was analysed and revealed that 89.6kg of Waste Electrical and Electronic Equipment (WEEE), 11kg of batteries, 2.2kg of toners and 16kg of cables had been wrongfully discarded. This corresponds to a Danish household discarding 29g of WEEE (7 items per year), 4g of batteries (9 batteries per year), 1g of toners and 7g of unidentifiable cables on average per week, constituting 0.34% (w/w), 0.04% (w/w), 0.01% (w/w) and 0.09% (w/w), respectively, of residual waste. The study also found that misplaced WEEE and batteries in the residual waste constituted 16% and 39%, respectively, of what is being collected properly through the dedicated special waste collection schemes. This shows that a large amount of batteries are being discarded with the residual waste, whereas WEEE seems to be collected relatively successfully through the dedicated special waste collection schemes. Characterisation of the misplaced batteries showed that 20% (w/w) of the discarded batteries were discarded as part of WEEE (built-in). Primarily alkaline batteries, carbon zinc batteries and alkaline button cell batteries were found to be discarded with the residual household waste. Characterisation of WEEE showed that primarily small WEEE (WEEE directive categories 2, 5a, 6, 7 and 9) and light sources (WEEE directive category 5b) were misplaced. Electric tooth brushes, watches, clocks, headphones, flashlights, bicycle lights, and cables were items most frequently found. It is recommended that these findings are taken into account when designing new or improving existing special waste collection schemes. Improving the collection of WEEE is also recommended as one way to also improve the collection of batteries due to the large fraction of batteries found as built-in. The findings in this study were comparable to other western European studies, suggesting that the recommendations made in this study could apply to other western European countries as well. Copyright © 2013 Elsevier Ltd. All rights reserved.
A robust ECC based mutual authentication protocol with anonymity for session initiation protocol.
Mehmood, Zahid; Chen, Gongliang; Li, Jianhua; Li, Linsen; Alzahrani, Bander
2017-01-01
Over the past few years, Session Initiation Protocol (SIP) is found as a substantial application-layer protocol for the multimedia services. It is extensively used for managing, altering, terminating and distributing the multimedia sessions. Authentication plays a pivotal role in SIP environment. Currently, Lu et al. presented an authentication protocol for SIP and profess that newly proposed protocol is protected against all the familiar attacks. However, the detailed analysis describes that the Lu et al.'s protocol is exposed against server masquerading attack and user's masquerading attack. Moreover, it also fails to protect the user's identity as well as it possesses incorrect login and authentication phase. In order to establish a suitable and efficient protocol, having ability to overcome all these discrepancies, a robust ECC-based novel mutual authentication mechanism with anonymity for SIP is presented in this manuscript. The improved protocol contains an explicit parameter for user to cope the issues of security and correctness and is found to be more secure and relatively effective to protect the user's privacy, user's masquerading and server masquerading as it is verified through the comprehensive formal and informal security analysis.
Improved Tensile Adhesion Specimens for High Strength Epoxy Systems in Aerospace Applications
NASA Technical Reports Server (NTRS)
Haddock, M. Reed; McLennan, Michael L.
2000-01-01
An improved tensile adhesion button has been designed and tested that results in higher measured tensile adhesion strength while providing increased capability for testing high strength epoxy adhesive systems. The best attributes of two well-established tensile button designs were combined and refined into an optimized tensile button. The most significant design change to the tensile button was to improve alignment of the bonded tensile button specimens during tensile testing by changing the interface between the tensile button and the tensile test machine. The established or old button design uses a test fixture that pulls from a grooved annulus or anvil head while the new button design pulls from a threaded hole in the centerline of the button. Finite element (FE) analysis showed that asymmetric loading of the established anvil head tensile button significantly increases the stress concentration in the adhesive, causing failure at lower tensile test loads. The new tensile button was designed to eliminate asymmetric loading and eliminate misalignment sensitivity. Enhanced alignment resulted in improved tensile adhesion strength measurement up to 13.8 MPa (2000psi) over the established button design. Another design change increased the capability of the button by increasing the threaded hole diameter allowing it to test high strength epoxy systems up to 85 MPa(less than 12,000 psi). The improved tensile button can be used in button- to-button or button-to-panel configurations.
Churg-Strauss syndrome masquerading as an acute coronary syndrome.
Triantafyllis, Andreas S; Sakadakis, Eleftherios A; Papafilippaki, Argyro; Katsimbri, Pelagia; Panou, Fotios; Anastasiou-Nana, Maria; Lekakis, Ioannis
2015-02-01
Churg-Strauss Syndrome (CSS) is a rare vasculitis with multiorgan involvement. Cardiac manifestations are common causing serious complications. We report a case of CSS masquerading as a non-ST elevation myocardial infarction with heart failure. CSS should be considered in the differential diagnosis of an acute coronary syndrome(ACS)with normal coronary arteries when history of asthma, peripheral eosinophilia and multisystemic involvement is present.
Evaluation of fire-safety programs that use 10-year smoke alarms.
Jackson, Mark; Wilson, Jonathan; Akoto, Judith; Dixon, Sherry; Jacobs, David E; Ballesteros, Michael F
2010-10-01
The Centers for Disease Control and Prevention began funding a Smoke Alarm Installation and Fire Safety Education (SAIFE) program in 1998. This program involves the installation of lithium-powered "10-year" smoke alarms in homes at high risk for fires and injuries. This study aimed to (1) determine among original SAIFE homes if the lithium-powered alarms were still present and functional 8-10 years after installation and (2) understand factors related to smoke alarm presence and functionality. Data on a total of 384 homes and 601 smoke alarms in five states were collected and analyzed. Only one-third of alarms were still functional; 37% of installed alarms were missing; and 30% of alarms were present, but not functioning. Alarms were less likely to be functioning if they were installed in the kitchen and if homes had a different resident at follow-up. Of the 351 alarms that were present and had a battery at the time of the evaluation, only 21% contained lithium-powered batteries. Of these, 78% were still functioning. Programs that install lithium-powered alarms should use units that have sealed-in batteries and "hush" buttons. Additionally, education should be given on smoke alarm maintenance that includes a message that batteries in these alarms should not be replaced. Lithium-powered smoke alarms should last up to 10 years if maintained properly.
[Pediatric poisoning, with special reference to household products].
Rauber-Lüthy, Christine; Staubli, Georg
2009-05-01
Poisoning in children with household products are common. The majority of these accidents are of low severity and resolve without complications. The big challenge for physicians is to reveal the few situations that could be life-threatening where immediate interventions is needed. The most commonly encountered substances in household products are detergents, alcohols (ethanol, isopropanol), hydrocarbons, as well as irritants (bleach, limescale removers). Rare but dangerous chemicals are for example "toxic alcohols" (methanol, ethylene glycol) and strong acids and alkalis. Also in case of ingestion of button batteries or magnets severe cases are uncommon but each case must be judged carefully to identify the cases where complications could appear.
["Habitual" left branch block alternating with 2 "disguised" bracnch block].
Lévy, S; Jullien, G; Mathieu, P; Mostefa, S; Gérard, R
1976-10-01
Two cases of alternating left bundle branch block and "masquerading block" (with left bundle branch morphology in the stnadard leads and right bundle branch block morphology in the precordial leads) were studied by serial tracings and his bundle electrocardiography. In case 1 "the masquerading" block was associated with a first degree AV block related to a prolongation of HV interval. This case is to our knowledge the first cas of alternating bundle branch block in which his bundle activity was recorded in man. In case 2, the patient had atrial fibrilation and His bundle recordings were performed while differents degrees of left bundle branch block were present: The mechanism of the alternation and the concept of "masquerading" block are discussed. It is suggested that this type of block represents a right bundle branch block associated with severe lesions of the "left system".
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bigum, Marianne, E-mail: mkkb@env.dtu.dk; Petersen, Claus, E-mail: claus_petersen@econet.dk; Christensen, Thomas H., E-mail: thho@env.dtu.dk
2013-11-15
Highlights: • We analyse 26.1 Mg of residual waste from 3129 Danish households. • We quantify and characterise misplaced WEEE and portable batteries. • We compare misplaced WEEE and batteries to collection through dedicated schemes. • Characterisation showed that primarily small WEEE and light sources are misplaced. • Significant amounts of misplaced batteries were discarded as built-in WEEE. - Abstract: A total of 26.1 Mg of residual waste from 3129 households in 12 Danish municipalities was analysed and revealed that 89.6 kg of Waste Electrical and Electronic Equipment (WEEE), 11 kg of batteries, 2.2 kg of toners and 16 kgmore » of cables had been wrongfully discarded. This corresponds to a Danish household discarding 29 g of WEEE (7 items per year), 4 g of batteries (9 batteries per year), 1 g of toners and 7 g of unidentifiable cables on average per week, constituting 0.34% (w/w), 0.04% (w/w), 0.01% (w/w) and 0.09% (w/w), respectively, of residual waste. The study also found that misplaced WEEE and batteries in the residual waste constituted 16% and 39%, respectively, of what is being collected properly through the dedicated special waste collection schemes. This shows that a large amount of batteries are being discarded with the residual waste, whereas WEEE seems to be collected relatively successfully through the dedicated special waste collection schemes. Characterisation of the misplaced batteries showed that 20% (w/w) of the discarded batteries were discarded as part of WEEE (built-in). Primarily alkaline batteries, carbon zinc batteries and alkaline button cell batteries were found to be discarded with the residual household waste. Characterisation of WEEE showed that primarily small WEEE (WEEE directive categories 2, 5a, 6, 7 and 9) and light sources (WEEE directive category 5b) were misplaced. Electric tooth brushes, watches, clocks, headphones, flashlights, bicycle lights, and cables were items most frequently found. It is recommended that these findings are taken into account when designing new or improving existing special waste collection schemes. Improving the collection of WEEE is also recommended as one way to also improve the collection of batteries due to the large fraction of batteries found as built-in. The findings in this study were comparable to other western European studies, suggesting that the recommendations made in this study could apply to other western European countries as well.« less
Monsalvo, Silvia; Serrano, Cristina; Prieto, Elena; Fernández-Sanz, Guillermo; Puente, Maria-Camino; Rodriguez-Pinilla, Maria; Garcia Raso, Aranzazu; Llamas, Pilar; Cordoba, Raul
2017-07-01
The uveitis masquerade syndromes (UMS) are a group of ocular diseases that may mimic chronic intraocular inflammation. Many malignant entities such as non-Hodgkin's lymphomas may masquerade as uveitis. We report a case of an HIV-positive patient with masquerade syndrome presenting unilateral uveitis. 45-year-old Caucasian man with a diagnosis of diffuse large B-cell lymphoma (DLBCL). The patient was diagnosed by a biopsy of an abdominal mass which showed fragments of gastric mucosa with diffuse growth of neoplastic cells. At diagnosis, the patient suffered from unilateral blurring of vision and a sudden decrease of left-eye visual acuity. A slit-lamp examination of the left eye revealed a diagnosis of anterior uveitis. The patient exhibited no signs of posterior uveitis. An anterior-chamber paracentesis was performed and analyzed by multiparameter flow cytometry (MFC), showing cells CD45, CD19, CD20, CD22, and CD38 positives, and moderate expression of CD10 with kappa light chain restriction, showing a monoclonal B-cell population. The patient received CHOP-R with intrathecal methotrexate followed by consolidation high dose methotrexate obtaining a complete response which is ongoing. Differential diagnosis between chronic uveitis and ocular lymphoma may be challenging. We advocate anterior-chamber paracentesis in cases of refractory uveitis in patients with hematologic malignancies. © 2016 International Clinical Cytometry Society. © 2016 International Clinical Cytometry Society.
Loop-mediated isothermal amplification (LAMP) shield for Arduino DNA detection.
Velders, Aldrik H; Schoen, Cor; Saggiomo, Vittorio
2018-02-01
Loop-mediated isothermal amplification (LAMP) of DNA is gaining relevance as a method to detect nucleic acids, as it is easier, faster, and more powerful than conventional Polymerase Chain Reaction. However, LAMP is still mostly used in laboratory settings, because of the lack of a cheap and easy, one-button device that can perform LAMP experiments. Here we show how to build and program an Arduino shield for a LAMP and detection of DNA. The here described Arduino Shield is cheap, easy to assemble, to program and use, it is battery operated and the detection of DNA is done by naked-eye so that it can be used in field.
... span class="tp-sr-only">Submit Button Submit Button Orange Button Solar Data Exchange | Energy Analysis | NREL
Orange Button Solar Data Exchange Orange Button Solar Data Exchange The new Orange Button Solar Data Exchange tool serves as an online resource for the solar industry to share, sell, or retrieve solar data and connect with colleagues. Screenshot image of Orange Button data website home page. The
Tourette Syndrome (TS): Risk Factors and Causes
... span class="tp-sr-only">Submit Button Submit Button Packaging - Materials review
NASA Astrophysics Data System (ADS)
Herrmann, Matthias
2014-06-01
Nowadays, a large number of different electrochemical energy storage systems are known. In the last two decades the development was strongly driven by a continuously growing market of portable electronic devices (e.g. cellular phones, lap top computers, camcorders, cameras, tools). Current intensive efforts are under way to develop systems for automotive industry within the framework of electrically propelled mobility (e.g. hybrid electric vehicles, plug-in hybrid electric vehicles, full electric vehicles) and also for the energy storage market (e.g. electrical grid stability, renewable energies). Besides the different systems (cell chemistries), electrochemical cells and batteries were developed and are offered in many shapes, sizes and designs, in order to meet performance and design requirements of the widespread applications. Proper packaging is thereby one important technological step for designing optimum, reliable and safe batteries for operation. In this contribution, current packaging approaches of cells and batteries together with the corresponding materials are discussed. The focus is laid on rechargeable systems for industrial applications (i.e. alkaline systems, lithium-ion, lead-acid). In principle, four different cell types (shapes) can be identified - button, cylindrical, prismatic and pouch. Cell size can be either in accordance with international (e.g. International Electrotechnical Commission, IEC) or other standards or can meet application-specific dimensions. Since cell housing or container, terminals and, if necessary, safety installations as inactive (non-reactive) materials reduce energy density of the battery, the development of low-weight packages is a challenging task. In addition to that, other requirements have to be fulfilled: mechanical stability and durability, sealing (e.g. high permeation barrier against humidity for lithium-ion technology), high packing efficiency, possible installation of safety devices (current interrupt device, valve, etc.), chemical inertness, cost issues, and others. Finally, proper cell design has to be considered for effective thermal management (i.e. cooling and heating) of battery packs.
NASA Technical Reports Server (NTRS)
1978-01-01
An ultra-reliable flashlight, initially developed for rescue signaling and utility use by NASA astronauts and military aircrews, has attracted a broad commercial market. Called the Five Year Light, it has a shelf life at least that long because there is no power drain on the batteries when the flashlight is not in use. The NASA version of the light was developed under contract with Langley Research Center by ACR Electronics, Inc., now known as the Chromalloy Electronics Division of Chromalloy American Corporation, Hollywood, Florida. NASA wanted a light that had long shelf life and assured reliability in case it was needed in an emergency. Reliability was designed into the flashlight by means of a unique switch. Instead of the customary thumb-button, the Five Year Light is turned on by rotating its collar to make contact with the battery terminal; the turning motion wipes away any corrosion that might be present and makes contact virtually certain. The Five Year Light available commercially is a repackaged version of the NASA light. It is sold for car, home, industrial, police, firefighting, recreational and a variety of other uses, and sales have topped two million units.
Illuminated push-button switch
NASA Technical Reports Server (NTRS)
Iwagiri, T.
1983-01-01
An illuminated push-button switch is described. It is characterized by the fact that is consists of a switch group, an operator button opening and closing the switch group, and a light-emitting element which illuminates the face of the operator button.
76 FR 54741 - Proposed Additions and Deletions
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-02
...-6823--Button, Silver Oxide, 1.55V. NSN: 6135-01-538-0997--Button, Lithium, 3V. NSN: 6135-01-452-8160--Button, Lithium, 3V. NSN: 6135-01-301-8776--Lithium, AA, 3.6V . NSN: 6135-01-246-0307--Button, Silver...
Turvey, Carolyn; Klein, Dawn; Fix, Gemmae; Hogan, Timothy P; Woods, Susan; Simon, Steven R; Charlton, Mary; Vaughan-Sarrazin, Mary; Zulman, Donna M; Dindo, Lilian; Wakefield, Bonnie; Graham, Gail; Nazi, Kim
2014-01-01
The Blue Button feature of online patient portals promotes patient engagement by allowing patients to easily download their personal health information. This study examines the adoption and use of the Blue Button feature in the Department of Veterans Affairs' (VA) personal health record portal, My HealtheVet. An online survey presented to a 4% random sample of My HealtheVet users between March and May 2012. Questions were designed to determine characteristics associated with Blue Button use, perceived value of use, and how Veterans with non-VA providers use the Blue Button to share information with their non-VA providers. Of the survey participants (N=18 398), 33% were current Blue Button users. The most highly endorsed benefit was that it helped patients understand their health history better because all the information was in one place (73%). Twenty-one percent of Blue Button users with a non-VA provider shared their VA health information, and 87% reported that the non-VA provider found the information somewhat or very helpful. Veterans' self-rated computer ability was the strongest factor contributing to both Blue Button use and to sharing information with non-VA providers. When comparing Blue Button users and non-users, barriers to adoption were low awareness of the feature and difficulty using the Blue Button. This study contributes to the understanding of early Blue Button adoption and use of this feature for patient-initiated sharing of health information. Educational efforts are needed to raise awareness of the Blue Button and to address usability issues that hinder adoption. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Design of temperature detection device for drum of belt conveyor
NASA Astrophysics Data System (ADS)
Zhang, Li; He, Rongjun
2018-03-01
For difficult wiring and big measuring error existed in the traditional temperature detection method for drum of belt conveyor, a temperature detection device for drum of belt conveyor based on Radio Frequency(RF) communication is designed. In the device, detection terminal can collect temperature data through tire pressure sensor chip SP370 which integrates temperature detection and RF emission. The receiving terminal which is composed of RF receiver chip and microcontroller receives the temperature data and sends it to Controller Area Network(CAN) bus. The test results show that the device meets requirements of field application with measuring error ±3.73 ° and single button battery can provide continuous current for the detection terminal over 1.5 years.
Research and exploration of product innovative design for function
NASA Astrophysics Data System (ADS)
Wang, Donglin; Wei, Zihui; Wang, Youjiang; Tan, Runhua
2009-07-01
Products innovation is under the prerequisite of realizing the new function, the realization of the new function must solve the contradiction. A new process model of new product innovative design was proposed based on Axiomatic Design (AD) Theory and Functional Structure Analysis (FSA), imbedded Principle of Solving Contradiction. In this model, employ AD Theory to guide FSA, determine the contradiction for the realization of the principle solution. To provide powerful support for innovative design tools in principle solution, Principle of Solving Contradiction in the model were imbedded, so as to boost up the innovation of principle solution. As a case study, an innovative design of button battery separator paper punching machine has been achieved with application of the proposed model.
Leadership Expand Leadership About NEPA Projects Expand NEPA Projects At Sea Expand At Sea Ashore Expand Ashore Stewards of the Sea Expand Stewards of the Sea Media Resources Expand Media Resources Contact NEPA Projects Button Environmental At Sea Button Environmental Ashore Button Energy Button Stewards of
Buresch, Kendra C; Ulmer, Kimberly M; Cramer, Corinne; McAnulty, Sarah; Davison, William; Mäthger, Lydia M; Hanlon, Roger T
2015-10-01
Cuttlefish use multiple camouflage tactics to evade their predators. Two common tactics are background matching (resembling the background to hinder detection) and masquerade (resembling an uninteresting or inanimate object to impede detection or recognition). We investigated how the distance and orientation of visual stimuli affected the choice of these two camouflage tactics. In the current experiments, cuttlefish were presented with three visual cues: 2D horizontal floor, 2D vertical wall, and 3D object. Each was placed at several distances: directly beneath (in a circle whose diameter was one body length (BL); at zero BL [(0BL); i.e., directly beside, but not beneath the cuttlefish]; at 1BL; and at 2BL. Cuttlefish continued to respond to 3D visual cues from a greater distance than to a horizontal or vertical stimulus. It appears that background matching is chosen when visual cues are relevant only in the immediate benthic surroundings. However, for masquerade, objects located multiple body lengths away remained relevant for choice of camouflage. © 2015 Marine Biological Laboratory.
{margin:0;padding:0;border:0;outline:0;line-height:1.3;text-decoration:none;font-size:100%;list-style:none -state-disabled{cursor:default!important}.ui-icon{display:block;text-indent:-99999px;overflow:hidden -align:middle;text-align:center;overflow:visible}.ui-button,.ui-button:link,.ui-button:visited,.ui-button:hover
Squamous cell carcinoma of penis with bullous pemphigoid masquerading as lymphogranuloma venereum
Venugopal, V.; Gnanaraj, Pushpa; Fernandes, S. D.; Narasimhan, Murali; Karthikeyan, Subashini; Rahul, Shwetha
2013-01-01
We report a case of a 60-year old unmarried male who presented with multiple ulcers and foul smelling discharge from the groin since 4 months and multiple tense bullae over the trunk of 1 month duration. Groove sign was present. Investigations for lymphogranuloma venereum (LGV) and other sexually transmitted diseases were negative. Histopathology from the ulcer in the groin and growth in the penis revealed squamous cell carcinoma (SCC). Skin biopsy of bulla was diagnostic of bullous pemphigoid (BP). We report a rare case of SCC masquerading as LGV with BP occurring as a paraneoplastic phenomenon. PMID:23919055
Systemic diffuse large B-cell lymphoma masquerading as neovascular glaucoma.
Bawankar, Pritam; Das, Dipankar; Bhattacharjee, Harsha; Tayab, Shahinur; Deori, Nilutparna; Paulbuddhe, Vivek; Dhar, Shriya; Deka, Apurba
2018-02-01
We describe a case of spontaneous hyphema associated with anterior uveitis presents in a 69-year old female as the prominent sign of the intraocular spread of systemic diffuse large B-cell lymphoma (DLBCL). She had a history of diabetes and initially misdiagnosed as neovascular glaucoma. Clinical history of systemic lymphoma, characteristic findings on B-scan ultrasonography and magnetic resonance imaging scan, and identification of atypical lymphoid cells in aqueous sample established the diagnosis of intraocular metastasis of systemic DLBCL. Therefore, this report highlights that life-threatening malignant systemic lymphoma may masquerade as anterior segment ocular inflammation or neovascular glaucoma.
A newly designed hydroxyapatite ceramic burr-hole button
Kashimura, Hiroshi; Ogasawara, Kuniaki; Kubo, Yoshitaka; Yoshida, Kenji; Sugawara, Atsushi; Ogawa, Akira
2010-01-01
Conventional burr-hole buttons sometimes do not fit the burr hole well due to the curvature of the surrounding bone. An irregular surface at the border between the button and the surrounding skull may appear unaesthetic. The major problem is the difference between the curvature radius of the skull and the burr-hole button in contact with the skull. To solve this problem, the authors designed a button made of hydroxyapatite ceramic to snugly fit the burr hole. The specifications of this device and its clinical application are described here. PMID:20448795
A newly designed hydroxyapatite ceramic burr-hole button.
Kashimura, Hiroshi; Ogasawara, Kuniaki; Kubo, Yoshitaka; Yoshida, Kenji; Sugawara, Atsushi; Ogawa, Akira
2010-03-24
Conventional burr-hole buttons sometimes do not fit the burr hole well due to the curvature of the surrounding bone. An irregular surface at the border between the button and the surrounding skull may appear unaesthetic. The major problem is the difference between the curvature radius of the skull and the burr-hole button in contact with the skull. To solve this problem, the authors designed a button made of hydroxyapatite ceramic to snugly fit the burr hole. The specifications of this device and its clinical application are described here.
View of button board which accommodates the 1200 button switches ...
View of button board which accommodates the 1200 button switches which manually control the indicating pilot lights on the model board. Not all switches are active, some switches were installed for a planned, but never constructed, system expansion. - Thirtieth Street Station, Load Dispatch Center, Thirtieth & Market Streets, Railroad Station, Amtrak (formerly Pennsylvania Railroad Station), Philadelphia, Philadelphia County, PA
A fast button surface defects detection method based on convolutional neural network
NASA Astrophysics Data System (ADS)
Liu, Lizhe; Cao, Danhua; Wu, Songlin; Wu, Yubin; Wei, Taoran
2018-01-01
Considering the complexity of the button surface texture and the variety of buttons and defects, we propose a fast visual method for button surface defect detection, based on convolutional neural network (CNN). CNN has the ability to extract the essential features by training, avoiding designing complex feature operators adapted to different kinds of buttons, textures and defects. Firstly, we obtain the normalized button region and then use HOG-SVM method to identify the front and back side of the button. Finally, a convolutional neural network is developed to recognize the defects. Aiming at detecting the subtle defects, we propose a network structure with multiple feature channels input. To deal with the defects of different scales, we take a strategy of multi-scale image block detection. The experimental results show that our method is valid for a variety of buttons and able to recognize all kinds of defects that have occurred, including dent, crack, stain, hole, wrong paint and uneven. The detection rate exceeds 96%, which is much better than traditional methods based on SVM and methods based on template match. Our method can reach the speed of 5 fps on DSP based smart camera with 600 MHz frequency.
Emotive concept nouns and motor responses: attraction or repulsion?
Freina, Laura; Baroni, Giulia; Borghi, Anna M; Nicoletti, Roberto
2009-06-01
We carried out three experiments aimed at testing whether hand posture affects the compatibility effect that Chen and Bargh (1999) found between a word's emotional connotation and arm movement direction. In the present study, participants responded by pressing two buttons: one placed near their body, the other far away. In Experiment 1, in which they pressed the response button with their hand open, RTs were shorter when participants pressed the far button for positive words and the near button for negative words, as if they simulated reaching for something good and avoiding something bad. However, in Experiments 2 and 3, in which participants pressed the response button with a tennis ball in their hand, RTs were shorter when participants pressed the near button for positive words and the far button for negative words, as if they simulated drawing a good thing closer and pushing a bad thing away. Results are discussed within the framework of theories on concept grounding in emotion and action systems.
Neary, Kaitlin C; Mormino, Matthew A; Wang, Hongmei
2017-01-01
In stress-positive, unstable supination-external rotation type 4 (SER IV) ankle fractures, implant selection for syndesmotic fixation is a debated topic. Among the available syndesmotic fixation methods, the metallic screw and the suture button have been routinely compared in the literature. In addition to strength of fixation and ability to anatomically restore the syndesmosis, costs associated with implant use have recently been called into question. This study aimed to examine the cost-effectiveness of the suture button and determine whether suture button fixation is more cost-effective than two 3.5-mm syndesmotic screws not removed on a routine postoperative basis. Economic and decision analysis; Level of evidence, 2. Studies with the highest evidence levels in the available literature were used to estimate the hardware removal and failure rates for syndesmotic screws and suture button fixation. Costs were determined by examining the average costs for patients who underwent surgery for unstable SER IV ankle fractures at a single level-1 trauma institution. A decision analysis model that allowed comparison of the 2 fixation methods was developed. Using a 20% screw hardware removal rate and a 4% suture button hardware removal rate, the total cost for 2 syndesmotic screws was US$20,836 and the total effectiveness was 5.846. This yielded a total cost of $3564 per quality-adjusted life-year (QALY) over an 8-year time period. The total cost for suture button fixation was $19,354 and the total effectiveness was 5.904, resulting in a total cost of $3294 per QALY over the same time period. A sensitivity analysis was then conducted to assess suture button fixation costs as well as screw and suture button hardware removal rates. Other possible treatment scenarios were also examined, including 1 screw and 2 suture buttons for operative fixation of the syndesmosis. To become more cost-effective, the screw hardware removal rate would have to be reduced to less than 10%. Furthermore, fixation with a single suture button continued to be the dominant treatment strategy compared with 2 suture buttons, 1 screw, and 2 screws for syndesmotic fixation. This cost-effectiveness analysis suggests that for unstable SER IV ankle fractures, suture button fixation is more cost-effective than syndesmotic screws not removed on a routine basis. Suture button fixation was a dominant treatment strategy, because patients spent on average $1482 less and had a higher quality of life by 0.058 QALYs compared with patients who received fixation with 2 syndesmotic screws. Assuming that functional outcomes and failure rates were equivalent, screw fixation only became more cost-effective when the screw hardware removal rate was reduced to less than 10% or when the suture button cost exceeded $2000. In addition, fixation with a single suture button device proved more cost-effective than fixation with either 1 or 2 syndesmotic screws.
The Emerging Role of 3-Dimensional Printing in Rhinology.
Stokken, Janalee K; Pallanch, John F
2017-06-01
Nasal septal perforations, particularly those that are large and irregular in shape, often present as challenging surgical dilemmas. New technology has allowed us to develop techniques using computed tomography imaging and 3-dimensional (3D) printers to design custom polymeric silicone septal buttons. These buttons offer patients an option that avoids a surgical intervention when standard buttons do not fit well or are not tolerated. Preliminary data suggest that buttons designed by 3D printer technology provide more comfort than standard commercially available or hand-carved buttons with equivalent reduction of symptoms. Copyright © 2017 Elsevier Inc. All rights reserved.
Klein, Dawn M; Fix, Gemmae M; Hogan, Timothy P; Simon, Steven R; Nazi, Kim M; Turvey, Carolyn L
2015-08-18
Information sharing between providers is critical for care coordination, especially in health systems such as the United States Department of Veterans Affairs (VA), where many patients also receive care from other health care organizations. Patients can facilitate this sharing by using the Blue Button, an online tool that promotes patients' ability to view, print, and download their health records. The aim of this study was to characterize (1) patients' use of Blue Button, an online information-sharing tool in VA's patient portal, My HealtheVet, (2) information-sharing practices between VA and non-VA providers, and (3) how providers and patients use a printed Blue Button report during a clinical visit. Semistructured qualitative interviews were conducted with 34 VA patients, 10 VA providers, and 9 non-VA providers. Interviews focused on patients' use of Blue Button, information-sharing practices between VA and non-VA providers, and how patients and providers use a printed Blue Button report during a clinical visit. Qualitative themes were identified through iterative rounds of coding starting with an a priori schema based on technology adoption theory. Information sharing between VA and non-VA providers relied primarily on the patient. Patients most commonly used Blue Button to access and share VA laboratory results. Providers recognized the need for improved information sharing, valued the Blue Button printout, and expressed interest in a way to share information electronically across settings. Consumer-oriented technologies such as Blue Button can facilitate patients sharing health information with providers in other health care systems; however, more education is needed to inform patients of this use to facilitate care coordination. Additional research is needed to explore how personal health record documents, such as Blue Button reports, can be easily shared and incorporated into the clinical workflow of providers.
Jones, Jake S.
1999-01-01
An apparatus and method of issuing commands to a computer by a user interfacing with a virtual reality environment. To issue a command, the user directs gaze at a virtual button within the virtual reality environment, causing a perceptible change in the virtual button, which then sends a command corresponding to the virtual button to the computer, optionally after a confirming action is performed by the user, such as depressing a thumb switch.
Sfondrini, Maria Francesca; Gatti, Sara; Scribante, Andrea
2011-07-01
Our aim was to assess the effect of blood contamination on the shear bonding strength and sites of failure of orthodontic brackets and bondable buttons. We randomly divided 160 bovine permanent mandibular incisors into 8 groups of 20 specimens each. Both orthodontic brackets (Step brackets, Leone, Sesto Fiorentino, Italy) and bondable buttons (Flat orthodontic buttons, Leone, Sesto Fiorentino, Italy) were tested on four different enamel surfaces: dry; contamination with blood before priming; after priming; and before and after priming. Brackets and buttons were bonded to the teeth and subsequently tested using a Instron universal testing machine. Shear bonding strength and the rate of adhesive failures were recorded. Data were analysed using the analysis of variance (ANOVA), Scheffè tests, and the chi-square test. Uncontaminated enamel surfaces showed the highest bonding strengths for both brackets and buttons. When they were contaminated with blood, orthodontic brackets had significantly lower shear strengths than bondable buttons (P=0.0001). There were significant differences in sites of failure among the groups for the various enamel surfaces (P=0.001). Contamination of enamel by blood during bonding lowers the strength of the bond, more so with orthodontic brackets than with bondable buttons. Copyright © 2010 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Herrmann, Matthias
2014-06-16
Nowadays, a large number of different electrochemical energy storage systems are known. In the last two decades the development was strongly driven by a continuously growing market of portable electronic devices (e.g. cellular phones, lap top computers, camcorders, cameras, tools). Current intensive efforts are under way to develop systems for automotive industry within the framework of electrically propelled mobility (e.g. hybrid electric vehicles, plug-in hybrid electric vehicles, full electric vehicles) and also for the energy storage market (e.g. electrical grid stability, renewable energies). Besides the different systems (cell chemistries), electrochemical cells and batteries were developed and are offered in manymore » shapes, sizes and designs, in order to meet performance and design requirements of the widespread applications. Proper packaging is thereby one important technological step for designing optimum, reliable and safe batteries for operation. In this contribution, current packaging approaches of cells and batteries together with the corresponding materials are discussed. The focus is laid on rechargeable systems for industrial applications (i.e. alkaline systems, lithium-ion, lead-acid). In principle, four different cell types (shapes) can be identified - button, cylindrical, prismatic and pouch. Cell size can be either in accordance with international (e.g. International Electrotechnical Commission, IEC) or other standards or can meet application-specific dimensions. Since cell housing or container, terminals and, if necessary, safety installations as inactive (non-reactive) materials reduce energy density of the battery, the development of low-weight packages is a challenging task. In addition to that, other requirements have to be fulfilled: mechanical stability and durability, sealing (e.g. high permeation barrier against humidity for lithium-ion technology), high packing efficiency, possible installation of safety devices (current interrupt device, valve, etc.), chemical inertness, cost issues, and others. Finally, proper cell design has to be considered for effective thermal management (i.e. cooling and heating) of battery packs.« less
Systemic diffuse large B-cell lymphoma masquerading as neovascular glaucoma
Bawankar, Pritam; Das, Dipankar; Bhattacharjee, Harsha; Tayab, Shahinur; Deori, Nilutparna; Paulbuddhe, Vivek; Dhar, Shriya; Deka, Apurba
2018-01-01
We describe a case of spontaneous hyphema associated with anterior uveitis presents in a 69-year old female as the prominent sign of the intraocular spread of systemic diffuse large B-cell lymphoma (DLBCL). She had a history of diabetes and initially misdiagnosed as neovascular glaucoma. Clinical history of systemic lymphoma, characteristic findings on B-scan ultrasonography and magnetic resonance imaging scan, and identification of atypical lymphoid cells in aqueous sample established the diagnosis of intraocular metastasis of systemic DLBCL. Therefore, this report highlights that life-threatening malignant systemic lymphoma may masquerade as anterior segment ocular inflammation or neovascular glaucoma. PMID:29380792
Idiopathic subvalvular aortic aneurysm masquerading as acute coronary syndrome.
Natarajan, Balaji; Ramanathan, Sundar; Subramaniam, Natarajan; Janardhanan, Rajesh
2016-09-02
Subvalvular aneurysms are the least common type of left ventricular (LV) aneurysms and can be fatal. Subaortic LV aneurysms are much rarer than submitral LV aneurysms and mostly reported in infancy. They can be congenital or acquired secondary to infections, cardiac surgery or trauma. Here, we report a unique presentation of a large, idiopathic subaortic aneurysm in an adult masquerading as an acute coronary syndrome. Diagnosis was made with the help of a CT aortography. Aneurysm was surgically resected with good results. This case highlights the clinical presentation and management of subaortic aneurysms, an important differential for congenital aortic malformations. 2016 BMJ Publishing Group Ltd.
Joan Riviere and the masquerade.
Hughes, Athol
2004-01-01
Although she published her paper "Womanliness as a masquerade" in 1929, Joan Riviere wrote it in 1928, the year that women in England got the vote. I want to consider the paper, her first original contribution to psychoanalytic thought, in the social and cultural context of the time, and then I shall focus on elements in it that relate to Joan Riviere's personal experiences and family influences that shaped her understanding of women and their sexuality. As well, I shall look at her views in relation to those of Freud, Klein and Jones. There is evidence that Riviere was speaking of herself in her descriptions of the "patient" in her paper, evidence that can be found in her diary and in the diary of her mother; as well as from interviews that I had with her daughter Diana. In addition there is a letter from Freud to Riviere that gives further evidence that she is writing about herself in this paper. The correspondence between Freud and Jones concerning Riviere and her analysis with Freud in 1922 also throws light on her experiences and on her personality that are similar to those of the "patient" she describes in "Womanliness as a masquerade."
... Home → Widgets and Buttons URL of this page: https://medlineplus.gov/widgets.html Widgets and Buttons To ... link the word MedlinePlus to the MedlinePlus homepage ( https://medlineplus.gov/ ). Search MedlinePlus : To put the MedlinePlus ...
Sfondrini, Maria Francesca; Fraticelli, Danilo; Gandini, Paola; Scribante, Andrea
2013-01-01
The aim of this study was to assess the effect of water and saliva contamination on the shear bond strength and failure site of orthodontic brackets and lingual buttons. 120 bovine permanent mandibular incisors were randomly divided into 6 groups of 20 specimens each. Both orthodontic brackets and disinclusion buttons were tested under three different enamel surface conditions: (a) dry, (b) water contamination, and (c) saliva contamination. Brackets and buttons were bonded to the teeth and subsequently tested using a Instron universal testing machine. Shear bond strength values and adhesive failure rate were recorded. Statistical analysis was performed using ANOVA and Tukey tests (strength values) and Chi squared test (ARI Scores). Noncontaminated enamel surfaces showed the highest bond strengths for both brackets and buttons. Under water and saliva contamination orthodontic brackets groups showed significantly lower shear strengths than disinclusion buttons groups. Significant differences in debond locations were found among the groups under the various enamel surface conditions. Water and saliva contamination of enamel during the bonding procedure lowers bond strength values, more with orthodontic brackets than with disinclusion buttons.
Jones, J.S.
1999-01-12
An apparatus and method of issuing commands to a computer by a user interfacing with a virtual reality environment are disclosed. To issue a command, the user directs gaze at a virtual button within the virtual reality environment, causing a perceptible change in the virtual button, which then sends a command corresponding to the virtual button to the computer, optionally after a confirming action is performed by the user, such as depressing a thumb switch. 4 figs.
EEG alpha activity and hallucinatory experience during sensory deprivation.
Hayashi, M; Morikawa, T; Hori, T
1992-10-01
The relationship between hallucinatory experiences under sensory deprivation and EEG alpha activities was studied. Each of seven male students lived alone in an air conditioned, soundproof dark room for 72 hours. When hallucinatory experiences occurred, the students pressed a button at once. If they could not press the button during the experience, they were required to press it two times when the hallucinatory experience was finished. Spectral analysis was performed on the consecutive EEG samples from just before button-presses to 10 min. before them, and the average alpha band amplitudes were obtained for the four epochs (0-.5, .5-2, 2-5, 5-10 min.). For the single button-presses, the amplitude of alpha band increased 2 min. before the button-presses. Right-hemisphere EEG activation was observed in the occipital area for the double button-presses. The results suggest an association between the hallucinatory experiences under sensory deprivation and the amount of EEG alpha activity.
Fix, Gemmae M; Hogan, Timothy P; Simon, Steven R; Nazi, Kim M; Turvey, Carolyn L
2015-01-01
Background Information sharing between providers is critical for care coordination, especially in health systems such as the United States Department of Veterans Affairs (VA), where many patients also receive care from other health care organizations. Patients can facilitate this sharing by using the Blue Button, an online tool that promotes patients’ ability to view, print, and download their health records. Objective The aim of this study was to characterize (1) patients’ use of Blue Button, an online information-sharing tool in VA’s patient portal, My HealtheVet, (2) information-sharing practices between VA and non-VA providers, and (3) how providers and patients use a printed Blue Button report during a clinical visit. Methods Semistructured qualitative interviews were conducted with 34 VA patients, 10 VA providers, and 9 non-VA providers. Interviews focused on patients’ use of Blue Button, information-sharing practices between VA and non-VA providers, and how patients and providers use a printed Blue Button report during a clinical visit. Qualitative themes were identified through iterative rounds of coding starting with an a priori schema based on technology adoption theory. Results Information sharing between VA and non-VA providers relied primarily on the patient. Patients most commonly used Blue Button to access and share VA laboratory results. Providers recognized the need for improved information sharing, valued the Blue Button printout, and expressed interest in a way to share information electronically across settings. Conclusions Consumer-oriented technologies such as Blue Button can facilitate patients sharing health information with providers in other health care systems; however, more education is needed to inform patients of this use to facilitate care coordination. Additional research is needed to explore how personal health record documents, such as Blue Button reports, can be easily shared and incorporated into the clinical workflow of providers. PMID:26286139
Sfondrini, Maria Francesca; Fraticelli, Danilo; Gandini, Paola
2013-01-01
Purpose. The aim of this study was to assess the effect of water and saliva contamination on the shear bond strength and failure site of orthodontic brackets and lingual buttons. Materials and Methods. 120 bovine permanent mandibular incisors were randomly divided into 6 groups of 20 specimens each. Both orthodontic brackets and disinclusion buttons were tested under three different enamel surface conditions: (a) dry, (b) water contamination, and (c) saliva contamination. Brackets and buttons were bonded to the teeth and subsequently tested using a Instron universal testing machine. Shear bond strength values and adhesive failure rate were recorded. Statistical analysis was performed using ANOVA and Tukey tests (strength values) and Chi squared test (ARI Scores). Results. Noncontaminated enamel surfaces showed the highest bond strengths for both brackets and buttons. Under water and saliva contamination orthodontic brackets groups showed significantly lower shear strengths than disinclusion buttons groups. Significant differences in debond locations were found among the groups under the various enamel surface conditions. Conclusions. Water and saliva contamination of enamel during the bonding procedure lowers bond strength values, more with orthodontic brackets than with disinclusion buttons. PMID:23762825
Evaluation of Heat Dissipation in the BPM Buttons
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pinayev,I.; Blednyhk, A.
2009-05-04
Growth of circulating current in the storage rings drastically increases heating of the beam position monitor (BPM) buttons due to the induced trapped modes is drastically increasing. Excessive heating can lead to the errors in the measuring of beam position or even catastrophic failures of the pick-up assembly. In this paper we present calculations of heat generated in the button for different geometries and materials. The obtained results are used for the optimization of the NSLS-II BPM buttons design.
Comparative Study of button BPM Trapped Mode Heating
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cameron,P.; Singh, O.
2009-05-04
The combination of short bunches and high currents found in modern light sources and colliders can result in the deposition of tens of watts of power in BPM buttons. The resulting thermal distortion is potentially problematic for maintaining high precision beam position stability, and in the extreme case can result in mechanical damage. We present a simple algorithm that uses the input parameters of beam current, bunch length, button diameter, beampipe aperture, and fill pattern to calculate a relative figure-of-merit for button heating. Data for many of the world's light sources and colliders is compiled in a table. Using themore » algorithm, the table is sorted in order of the relative magnitude of button heating.« less
Jiao, Zhenyu; Tian, Ying; Yang, Xinchun; Liu, Xingpeng
2017-10-01
A 59-year-old male patient was admitted with the main complaints of stuffiness and shortness of breath. An ECG from precordial leads on admission showed masquerading bundle branch block. Syncope frequently occurred after admission. During syncope episodes, ECG telemetry showed that the syncope was caused by intermittent complete atrioventricular block, with the longest RR interval lasting for 4.36 s. At the gap of syncope, ECG showed complete right bundle branch block accompanied by alternation of left anterior fascicular block and left posterior fascicular block. The patient was implanted with a dual-chamber permanent pacemaker. Follow-up of 9 months showed no reoccurrence of syncope.
Dukic, T; Hanson, L; Falkmer, T
2006-01-15
The study examined the effects of manual control locations on two groups of randomly selected young and old drivers in relation to visual time off road, steering wheel deviation and safety perception. Measures of visual time off road, steering wheel deviations and safety perception were performed with young and old drivers during real traffic. The results showed an effect of both driver's age and button location on the dependent variables. Older drivers spent longer visual time off road when pushing the buttons and had larger steering wheel deviations. Moreover, the greater the eccentricity between the normal line of sight and the button locations, the longer the visual time off road and the larger the steering wheel deviations. No interaction effect between button location and age was found with regard to visual time off road. Button location had an effect on perceived safety: the further away from the normal line of sight the lower the rating.
A diagnostic approach for cerebral palsy in the genomic era.
Lee, Ryan W; Poretti, Andrea; Cohen, Julie S; Levey, Eric; Gwynn, Hilary; Johnston, Michael V; Hoon, Alexander H; Fatemi, Ali
2014-12-01
An ongoing challenge in children presenting with motor delay/impairment early in life is to identify neurogenetic disorders with a clinical phenotype, which can be misdiagnosed as cerebral palsy (CP). To help distinguish patients in these two groups, conventional magnetic resonance imaging of the brain has been of great benefit in "unmasking" many of these genetic etiologies and has provided important clues to differential diagnosis in others. Recent advances in molecular genetics such as chromosomal microarray and next-generation sequencing have further revolutionized the understanding of etiology by more precisely classifying these disorders with a molecular cause. In this paper, we present a review of neurogenetic disorders masquerading as cerebral palsy evaluated at one institution. We have included representative case examples children presenting with dyskinetic, spastic, and ataxic phenotypes, with the intent to highlight the time-honored approach of using clinical tools of history and examination to focus the subsequent etiologic search with advanced neuroimaging modalities and molecular genetic tools. A precise diagnosis of these masqueraders and their differentiation from CP is important in terms of therapy, prognosis, and family counseling. In summary, this review serves as a continued call to remain vigilant for current and other to-be-discovered neurogenetic masqueraders of cerebral palsy, thereby optimizing care for patients and their families.
A Diagnostic Approach for Cerebral Palsy in the Genomic Era
Lee, Ryan W.; Poretti, Andrea; Cohen, Julie S.; Levey, Eric; Gwynn, Hilary; Johnston, Michael V.; Hoon, Alexander H.; Fatemi, Ali
2014-01-01
An ongoing challenge in children presenting with motor delay/impairment early in life is to identify neurogenetic disorders with a clinical phenotype which can be misdiagnosed as cerebral palsy (CP). To help distinguish patients in these two groups, conventional magnetic resonance imaging (MRI) of the brain has been of great benefit in “unmasking” many of these genetic etiologies and has provided important clues to differential diagnosis in others. Recent advances in molecular genetics such as chromosomal microarray and next generation sequencing have further revolutionized the understanding of etiology by more precisely classifying these disorders with a molecular cause. In this paper, we present a review of neurogenetic disorders masquerading as cerebral palsy evaluated at one institution. We have included representative case examples children presenting with dyskinetic, spastic and ataxic phenotypes, with the intent to highlight the time honored approach of using clinical tools of history and examination to focus the subsequent etiologic search with advanced neuroimaging modalities and molecular genetic tools. A precise diagnosis of these masqueraders and their differentiation from CP is important in terms of therapy, prognosis, and family counseling. In summary, this review serves as a continued call to remain vigilant for current and other to-be-discovered neurogenetic masqueraders of cerebral palsy, thereby optimizing care for patients and their families. PMID:25280894
Colcuc, Christian; Blank, Marc; Stein, Thomas; Raimann, Florian; Weber-Spickschen, Sanjay; Fischer, Sebastian; Hoffmann, Reinhard
2017-12-09
Suture button devices for tibiofibular syndesmosis injuries provide semirigid dynamic stabilization, but complications including knot irritation have been reported. No randomized trials of the new knotless suture button devices have been performed. We hypothesized that knotless suture button devices eliminate knot irritation and facilitate quicker return to sports. This study was performed to compare the clinical outcomes, complication rates, and time to return to sports between a new knotless suture button device and syndesmotic screw fixation. This study included 54 patients treated for ankle syndesmotic injury from 2012 to 2014 with a knotless suture button device or syndesmotic screw fixation. Clinical outcomes were measured using the American Orthopaedics Foot and Ankle Society score, Foot and Ankle Disability Index, Olerud and Molander score, and visual analog scale for pain and function. Secondary outcome measures were the complication rate and time required to return to sports. Patients underwent clinical and radiological evaluations preoperatively and three times during the 1-year postoperative follow-up. 54 of 62 eligible patients were analyzed, median age 37 (18-60) and underwent the 1-year follow-up. The screw fixation and knotless suture button groups comprised 26 and 28 patients, respectively. The complication rate was significantly lower (p = 0.03) and time to return to sports was significantly shorter in the knotless suture button than screw fixation group (average, 14 versus 19 weeks, respectively; p = 0.006). No significant differences were identified in clinical outcomes or visual analog scale scores for pain and function between the groups. Age, injury mechanism, and body mass index did not significantly affect the time required to return to sports activities. The type of fixation was the only independent variable that reached statistical significance (p = 0.006). Syndesmotic screw fixation and the new knotless suture button device both resulted in good clinical results. Lower complication rate and the earlier time to return to sports make the new knotless suture button device recommendable especially for highly active patients. Randomized controlled trial, Level I.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2000-04-01
The NITON{reg_sign} 800 series analyzer is a hand-held, battery operated unit that measures 8-in x 3-in x 2-in and weighs 2.5 pounds. The analyzer uses x-ray fluorescence spectrum analysis to identify and quantify elements in metal and then compares the readings to a built-in library to determine a metal's alloy. The library contains 300 elements and alloys, and can be customized to identify other elements and alloys (depending on the sources in the instrument). The basic unit utilizes a Cadmium-109 source, but each analyzer unit can hold up to two sources. These sources include Iron-55 and Americium-241. Pushing a safetymore » button located on the side of the unit and placing it against a surface opens the shutter window. Within seconds the unit beeps, and displays the results. The analyzer stores up to 1,000 data sets, including sample identification codes using a barcode reader. The data is easily downloaded to a conventional computer when sampling has been completed. Batteries are good for 8-hrs and charge in less than 2 hours and it can be carried, shipped, or transported without exterior labeling, conforming to 49 CFR 143.421.« less
46 CFR 160.037-3 - Materials, workmanship, construction, and performance requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... on its top with a friction striking material which shall, by a pull of the tear strip, be entirely exposed for striking the friction igniter button. The igniter button shall be non-water soluble or be... manner as to provide positive ignition by the friction striker. The igniter button shall be firmly...
46 CFR 160.037-3 - Materials, workmanship, construction, and performance requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... on its top with a friction striking material which shall, by a pull of the tear strip, be entirely exposed for striking the friction igniter button. The igniter button shall be non-water soluble or be... manner as to provide positive ignition by the friction striker. The igniter button shall be firmly...
46 CFR 160.037-3 - Materials, workmanship, construction, and performance requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... on its top with a friction striking material which shall, by a pull of the tear strip, be entirely exposed for striking the friction igniter button. The igniter button shall be non-water soluble or be... manner as to provide positive ignition by the friction striker. The igniter button shall be firmly...
46 CFR 160.037-3 - Materials, workmanship, construction, and performance requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... on its top with a friction striking material which shall, by a pull of the tear strip, be entirely exposed for striking the friction igniter button. The igniter button shall be non-water soluble or be... manner as to provide positive ignition by the friction striker. The igniter button shall be firmly...
Wei, Zhuang; Thoreson, Andrew R.; Amadio, Peter C.; An, Kai-Nan; Zhao, Chunfeng
2014-01-01
We compared the mechanical force of tendon-to-bone repair techniques for flexor tendon reconstruction. Thirty-six flexor digitorum profundus (FDP) tendons were divided into three groups based upon the repair technique: (1) suture/button repair using FDP tendon (Pullout button group), (2) suture bony anchor using FDP tendon (Suture anchor group), and (3) suture/button repair using FDP tendon with its bony attachment preserved (Bony attachment group). The repair failure force and stiffness were measured. The mean load to failure and stiffness in the bony attachment group were significantly higher than that in the pullout button and suture anchor groups. No significant difference was found in failure force and stiffness between the pullout button and suture anchor groups. An intrasynovial flexor tendon graft with its bony attachment has significantly improved tensile properties at the distal repair site when compared with a typical tendon-to-bone attachment with a button or suture anchor. The improvement in the tensile properties at the repair site may facilitate postoperative rehabilitation and reduce the risk of graft rupture. PMID:23754507
Results from a Test Fixture for button BPM Trapped Mode Measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cameron,P.; Bacha, B.; Blednykh, A.
2009-05-04
A variety of measures have been suggested to mitigate the problem of button BPM trapped mode heating. A test fixture, using a combination of commercial-off-the-shelf and custom machined components, was assembled to validate the simulations. We present details of the fixture design, measurement results, and a comparison of the results with the simulations. A brief history of the trapped mode button heating problem and a set of design rules for BPM button optimization are presented elsewhere in these proceedings. Here we present measurements on a test fixture that was assembled to confirm, if possible, a subset of those rules: (1)more » Minimize the trapped mode impedance and the resulting power deposited in this mode by the beam. (2) Maximize the power re-radiated back into the beampipe. (3) Maximize electrical conductivity of the outer circumference of the button and minimize conductivity of the inner circumference of the shell, to shift power deposition from the button to the shell. The problem is then how to extract useful and relevant information from S-parameter measurements of the test fixture.« less
The Blue Button Project: Engaging Patients in Healthcare by a Click of a Button.
Mohsen, Mona Omar; Aziz, Hassan A
2015-01-01
The Blue Button project has become a way for many Americans to download their health records by just a click in any way that suits them, such as in print, on a thumb drive, or on their mobile devices and smartphones. Several organizations have developed and applied Blue Buttons on their websites to allow beneficiaries to securely access and view personal medical information and claims. The purpose of this literature review is to highlight the significance of the Blue Button project in the field of health information management. Findings suggest that the project could empower and engage consumers and patients in a healthcare system by allowing access to medical records, thereby promoting better management and overall improvement of their healthcare. To date, the project has gained wide support from insurers, technology companies, and health providers despite the challenges of standardization and interoperability.
BPM Button Optimization to Minimize Distortion Due to Trapped Mode Heating
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cameron,P.; Blednyk, A.; Kosciuk, B.
2009-05-04
The outer circumference of a BPM button and the inner circumference of the button housing comprise a transmission line. This transmission line typically presents an impedance of a few tens of ohms to the beam, and couples very weakly to the 50 ohm coaxial transmission line that comprises the signal path out of the button. The modes which are consequently excited and trapped often have quality factors of several hundred, permitting resonant excitation by the beam. The thermal distortion resulting from trapped mode heating is potentially problematic for achieving the high precision beam position measurements needed to provide the sub-micronmore » beam position stability required by light source users. We present a button design that has been optimized via material selection and component geometry to minimize both the trapped mode heating and the resulting thermal distortion.« less
The Blue Button Project: Engaging Patients in Healthcare by a Click of a Button
Mohsen, Mona Omar; Aziz, Hassan A.
2015-01-01
The Blue Button project has become a way for many Americans to download their health records by just a click in any way that suits them, such as in print, on a thumb drive, or on their mobile devices and smartphones. Several organizations have developed and applied Blue Buttons on their websites to allow beneficiaries to securely access and view personal medical information and claims. The purpose of this literature review is to highlight the significance of the Blue Button project in the field of health information management. Findings suggest that the project could empower and engage consumers and patients in a healthcare system by allowing access to medical records, thereby promoting better management and overall improvement of their healthcare. To date, the project has gained wide support from insurers, technology companies, and health providers despite the challenges of standardization and interoperability. PMID:26755898
NASA Astrophysics Data System (ADS)
Nakazono, Shogo; Kobori, Satoshi
The button-press task means that the subject observes a moving target and presses a button to stop it when the target enters a specified area on a computer display. Subjects perform normal task, suppressed task and delayed task. In the suppressed task, the moving target disappears at some point during the trial. In the delayed task, there is some lag time between the time of pressing button and of stopping target. In these tasks, subjects estimate the movement of the target, and press the button considering his/her own reaction time. In our previous study, we showed that cognitive and motor function was able to be evaluated by these tasks. In this study, we examined error data of children with developmental disabilities to evaluate the cognitive function, and investigated the learning processes. Moreover, we discussed the developmental stages by comparing the children with disabilities to normal control children, and we clarified the behavior characteristics of children with developmental disabilities. Asa result, it was shown that our evaluation method and system for the button-press task were effective to evaluate cognitive ability of children with developmental disabilities.
Sumanont, Sermsak; Nopamassiri, Supachoke; Boonrod, Artit; Apiwatanakul, Punyawat; Boonrod, Arunnit; Phornphutkul, Chanakarn
2018-03-20
Suspension suture button fixation was frequently used to treat acromioclavicular joint (ACJ) dislocation. However, there were many studies reporting about complications and residual horizontal instability after fixation. Our study compared the stability of ACJ after fixation between coracoclavicular (CC) fixation alone and CC fixation combined with ACJ repair by using finite element analysis (FEA). A finite element model was created by using CT images from the normal shoulder. The model 1 was CC fixation with suture button alone, and the model 2 was CC fixation with suture button combined with ACJ repair. Three different forces (50, 100, 200 N) applied to the model in three planes; inferior, anterior and posterior direction load to the acromion. The von Mises stress of the implants and deformation at ACJs was recorded. The ACJ repair in the model 2 could reduce the peak stress on the implant after applying the loading forces to the acromion which the ACJ repair could reduce the peak stress of the FiberWire at suture button about 90% when compared to model 1. And, the ACJ repair could reduce the deformation of the ACJ after applying the loading forces to the acromion in both vertical and horizontal planes. This FEA supports that the high-grade injuries of the ACJ should be treated with CC fixation combined with ACJ repair because this technique provides excellent stability in both vertical and horizontal planes and reduces stress to the suture button.
Low-Cost Avoidance Behaviors are Resistant to Fear Extinction in Humans
Vervliet, Bram; Indekeu, Ellen
2015-01-01
Elevated levels of fear and avoidance are core symptoms across the anxiety disorders. It has long been known that fear serves to motivate avoidance. Consequently, fear extinction has been the primary focus in pre-clinical anxiety research for decades, under the implicit assumption that removing the motivator of avoidance (fear) would automatically mitigate the avoidance behaviors as well. Although this assumption has intuitive appeal, it has received little scientific scrutiny. The scarce evidence from animal studies is mixed, while the assumption remains untested in humans. The current study applied an avoidance conditioning protocol in humans to investigate the effects of fear extinction on the persistence of low-cost avoidance. Online danger-safety ratings and skin conductance responses documented the dynamics of conditioned fear across avoidance and extinction phases. Anxiety- and avoidance-related questionnaires explored individual differences in rates of avoidance. Participants first learned to click a button during a predictive danger signal, in order to cancel an upcoming aversive electrical shock (avoidance conditioning). Next, fear extinction was induced by presenting the signal in the absence of shocks while button-clicks were prevented (by removing the button in Experiment 1, or by instructing not to click the button in Experiment 2). Most importantly, post-extinction availability of the button caused a significant return of avoidant button-clicks. In addition, trait-anxiety levels correlated positively with rates of avoidance during a predictive safety signal, and with the rate of pre- to post-extinction decrease during this signal. Fear measures gradually decreased during avoidance conditioning, as participants learned that button-clicks effectively canceled the shock. Preventing button-clicks elicited a sharp increase in fear, which subsequently extinguished. Fear remained low during avoidance testing, but danger-safety ratings increased again when button-clicks were subsequently prevented. Together, these results show that low-cost avoidance behaviors can persist following fear extinction and induce increased threat appraisal. On the other hand, fear extinction did reduce augmented rates of unnecessary avoidance during safety in trait-anxious individuals, and instruction-based response prevention was more effective than removal of response cues. More research is needed to characterize the conditions under which fear extinction might mitigate avoidance. PMID:26733837
NASA Astrophysics Data System (ADS)
Xie, Dong-Fan; Zhao, Xiao-Mei; Li, Xin-Gang; Zhu, Tai-Lang
2016-01-01
Crosswalk with push button is prevalent in lots of cities for the purpose of promoting the efficiency of the crosswalk, and thus the delays of both vehicles and pedestrians can be reduced. This strategy has been confirmed to be effective in several developed countries. However, it is a pity that application of push button is aborted in some cities in China. In this work, diverse behaviors of vehicles and pedestrians are analyzed and discussed. Then, a microscopic model is developed by incorporating the interaction between vehicles and pedestrians. Numerical simulations are performed to reveal the characteristics of traffic flow and the efficiency of the signal control strategy. Also, the impacts of risker proportion and button reaction time, as well as the impacts of various behaviors as mass behavior, the patience of pedestrian and push button habit are investigated. It is expected that the results will be helpful to the strategy design of a signalized crosswalk in such developing countries as China.
Management of nasal septal perforation using silicone nasal septal button
Mullace, M; Gorini, E; Sbrocca, M; Artesi, L; Mevio, N
2006-01-01
Summary Nasal septal perforation may present with various symptoms: epistaxis, crusting, secondary infection, whistling and nasal obstruction. Perforation may be treated by conservative pharmacological treatment or closed by surgical approach. A useful alternative is mechanical obturation, achieved inserting a prosthesis. The present report refers to a study on 15 patients (10 male, 5 female, mean age 38.5 years) treated by insertion of a one-piece or two-piece silicone septal button (Xomed). In the follow-up period, insertion of the nasal button reduced epistaxis, eliminated whistling during inspiration, and reduced nasal obstruction and crusting around the margin of the perforation. Contraindications are presence of acute infection with osteitis, chronic septal disease (Wegener), neoplasia and extremely large perforations. The latest buttons appear to be superior to the conventional type on account of plasticity and adaptability which offer greater conformity to the septum. This study also reveals that the new septal button is well tolerated by patients. PMID:18236638
Kohrs, Christin; Hrabal, David; Angenstein, Nicole; Brechmann, André
2014-11-01
System response time research is an important issue in human-computer interactions. Experience with technical devices and general rules of human-human interactions determine the user's expectation, and any delay in system response time may lead to immediate physiological, emotional, and behavioral consequences. We investigated such effects on a trial-by-trial basis during a human-computer interaction by measuring changes in skin conductance (SC), heart rate (HR), and the dynamics of button press responses. We found an increase in SC and a deceleration of HR for all three delayed system response times (0.5, 1, 2 s). Moreover, the data on button press dynamics was highly informative since subjects repeated a button press with more force in response to delayed system response times. Furthermore, the button press dynamics could distinguish between correct and incorrect decisions and may thus even be used to infer the uncertainty of a user's decision. Copyright © 2014 Society for Psychophysiological Research.
How to Use This Website | USDA Plant Hardiness Zone Map
, regional or national plant hardiness zone maps in three different resolutions using the following steps. To default printing menu option or button. Viewing the Map - Open Full Map Button c. Save Full Map Button can copy the e-mail address and paste it into a different e-mail client (e.g., Google Gmail, Yahoo
Modification of Shirt Buttons for Retrospective Radiation Dosimetry after a Radiological Event
Marino, Stephen A.; Johnson, Gary W.; Schiff, Peter B.; Brenner, David J.
2010-01-01
Preliminary results are presented for a personal radiation dosimeter in the form of a clothing button to provide gamma-ray dose estimation for clinically significant external radiation exposures to the general public due to a radiological incident, such as a Radiological Dispersal Device. Rods of thermoluminescent material (LiF:Mg,Ti and LiF:Mg,Cu,P) were encapsulated in plastic “buttons”, attached to shirts, and subjected to three cycles of home or commercial laundering or dry cleaning, including ironing or pressing. The buttons were subsequently exposed to doses of 137Cs gamma rays ranging from 0.75 to 8.2 Gy. The rods were removed from the buttons and their light output compared to their responses when bare or to the responses of a set of calibration rods of the same type and from the same manufacturer. In all three of the comparisons for LiF:Mg,Ti rods the relative responses of the rods in buttons changed by 2-6% relative to the same rods before cleaning. In both comparisons for LiF:Mg,Cu,P rods, the response of laundered rods was 1-3% lower than for the same rods before cleaning. Both these materials are potential candidates for button dosimeters. PMID:21451325
Thermocron iButton and iBBat temperature dataloggers emit ultrasound.
Willis, Craig K R; Jameson, Joel W; Faure, Paul A; Boyles, Justin G; Brack, Virgil; Cervone, Tom H
2009-10-01
Thermocron iButton dataloggers are widely used to measure thermal microclimates experienced by wild animals. The iBBat is a smaller version of the datalogger, also commercially available, that is used to measure animal skin or core body temperatures when attached externally or surgically implanted. Field observations of bats roosting under a bridge suggested that bats avoided locations with iButtons. A heterodyne bat detector revealed that the dataloggers emitted ultrasound which was detectable from a distance of up to 30 cm. We therefore recorded and quantified the acoustic properties [carrier frequency (Hz) and root mean square sound pressure level (dB SPL)] of iButton and iBBat dataloggers. All units emitted a 32.9 kHz pure tone that was readily picked up with a time expansion bat detector at a distance of 1 cm, and most were detected at a distance of 15 cm. The maximum amplitude of iButton dataloggers was 46.5 dB SPL at 1.0 cm-a level within the range of auditory sensitivity for most small mammals. Wrapping iButtons in plastic insulation severely attenuated the amplitude of ultrasound. Although there was a statistically significant reduction in rates of warming and cooling with insulation, this effect was small and we suggest that insulation may be a viable solution to eliminate unwanted ultrasonic noise in instances when small delays in thermal response dynamics are not a concern. We recommend behavioural studies to assess if the electronic signals emitted by iButtons are disturbing to small mammals.
Learning processes underlying avoidance of negative outcomes.
Andreatta, Marta; Michelmann, Sebastian; Pauli, Paul; Hewig, Johannes
2017-04-01
Successful avoidance of a threatening event may negatively reinforce the behavior due to activation of brain structures involved in reward processing. Here, we further investigated the learning-related properties of avoidance using feedback-related negativity (FRN). The FRN is modulated by violations of an intended outcome (prediction error, PE), that is, the bigger the difference between intended and actual outcome, the larger the FRN amplitude is. Twenty-eight participants underwent an operant conditioning paradigm, in which a behavior (button press) allowed them to avoid a painful electric shock. During two learning blocks, participants could avoid an electric shock in 80% of the trials by pressing one button (avoidance button), or by not pressing another button (punishment button). After learning, participants underwent two test blocks, which were identical to the learning ones except that no shocks were delivered. Participants pressed the avoidance button more often than the punishment button. Importantly, response frequency increased throughout the learning blocks but it did not decrease during the test blocks, indicating impaired extinction and/or habit formation. In line with a PE account, FRN amplitude to negative feedback after correct responses (i.e., unexpected punishment) was significantly larger than to positive feedback (i.e., expected omission of punishment), and it increased throughout the blocks. Highly anxious individuals showed equal FRN amplitudes to negative and positive feedback, suggesting impaired discrimination. These results confirm the role of negative reinforcement in motivating behavior and learning, and reveal important differences between high and low anxious individuals in the processing of prediction errors. © 2017 Society for Psychophysiological Research.
Soft and wet actuator developed with responsible high-strength gels
NASA Astrophysics Data System (ADS)
Harada, S.; Hidema, R.; Furukawa, H.
2012-04-01
Novel high-strength gels, named double network gels (DN gels), show a smart response to altering external electric field. It was reported that a plate shape of the DN gel bends toward a positive electrode direction when a static (DC) electric field is applied. Based on this previous result, it has been tried to develop a novel soft and wet actuator, which will be used as an automatically bulging button for cellar phones, or similar small devices. First, a bending experiment of a hung plate-shape DN gel was done, and its electric field response was confirmed. Second, the response of a lying plate-shape DN gels was confirmed in order to check the bulging phenomena. The edge of three plate-shape gels that was arranged radially on a plane surface was lifted 2mm by applying DC 8V. This system is a first step to make a gels button. However the critical problem is that electrolysis occurs simultaneously under electric field. Then, the water sweep out from gels, and gels is shrinking; They cause the separation between aluminum foil working as electrode and gels. That is why, a flexible electrode should be made by gels completely attached to the gels. As a third step, a push button is tried to make by a shape memory gels (SMG). The Young's modulus of the SMG is dramatically changed by temperature. This change in the modulus is applied to control the input-acceptable state and input-not-acceptable states of the button. A novel push button is proposed as a trial, and its user-friendliness is checked by changing the size of the button. The button is deformed by pushing and is back to original shape due to the property of shape memory. We believe the mechanism of this button will be applied to develop new devices especially for visually impaired persons.
A PC parallel port button box provides millisecond response time accuracy under Linux.
Stewart, Neil
2006-02-01
For psychologists, it is sometimes necessary to measure people's reaction times to the nearest millisecond. This article describes how to use the PC parallel port to receive signals from a button box to achieve millisecond response time accuracy. The workings of the parallel port, the corresponding port addresses, and a simple Linux program for controlling the port are described. A test of the speed and reliability of button box signal detection is reported. If the reader is moderately familiar with Linux, this article should provide sufficient instruction for him or her to build and test his or her own parallel port button box. This article also describes how the parallel port could be used to control an external apparatus.
Zheng, Fang; Motulsky, Elie H; de Oliveira Dias, João Rafael; de López, Edith Pérez; Gregori, Giovanni; Rosenfeld, Philip J
2018-05-01
To demonstrate the advantage of optical coherence tomography angiography (OCTA) for the diagnosis and management of proliferative macular telangiectasia type 2 (MacTel2) masquerading as neovascular age-related macular degeneration (AMD). This is an observational cases series. Three patients referred with the diagnosis of neovascular AMD were identified in this retrospective study. In addition to color fundus, fluorescein angiography, and spectral-domain OCT (SD-OCT) imaging, SD-OCTA (AngioPlex; Carl Zeiss Meditec, Dublin, CA) was performed. SD-OCTA revealed bilateral parafoveal retinal microvascular changes in three patients and unambiguously confirmed the diagnosis of MacTel2. OCTA is an important tool for the correct diagnosis of MacTel2 in older patients with the concomitant or masquerading diagnosis of AMD. [Ophthalmic Surg Lasers Imaging Retina. 2018;49:303-312.]. Copyright 2018, SLACK Incorporated.
A Jungle in There: Bacteria in Belly Buttons are Highly Diverse, but Predictable
Hulcr, Jiri; Latimer, Andrew M.; Henley, Jessica B.; Rountree, Nina R.; Fierer, Noah; Lucky, Andrea; Lowman, Margaret D.; Dunn, Robert R.
2012-01-01
The belly button is one of the habitats closest to us, and yet it remains relatively unexplored. We analyzed bacteria and arachaea from the belly buttons of humans from two different populations sampled within a nation-wide citizen science project. We examined bacterial and archaeal phylotypes present and their diversity using multiplex pyrosequencing of 16S rDNA libraries. We then tested the oligarchy hypothesis borrowed from tropical macroecology, namely that the frequency of phylotypes in one sample of humans predicts its frequency in another independent sample. We also tested the predictions that frequent phylotypes (the oligarchs) tend to be common when present, and tend to be more phylogenetically clustered than rare phylotypes. Once rarefied to four hundred reads per sample, bacterial communities from belly buttons proved to be at least as diverse as communities known from other skin studies (on average 67 bacterial phylotypes per belly button). However, the belly button communities were strongly dominated by a few taxa: only 6 phylotypes occurred on >80% humans. While these frequent bacterial phylotypes (the archaea were all rare) are a tiny part of the total diversity of bacteria in human navels (<0.3% of phylotypes), they constitute a major portion of individual reads (∼1/3), and are predictable among independent samples of humans, in terms of both the occurrence and evolutionary relatedness (more closely related than randomly drawn equal sets of phylotypes). Thus, the hypothesis that “oligarchs” dominate diverse assemblages appears to be supported by human-associated bacteria. Although it remains difficult to predict which species of bacteria might be found on a particular human, predicting which species are most frequent (or rare) seems more straightforward, at least for those species living in belly buttons. PMID:23144827
van Vliet, Marijn; Manyakov, Nikolay V.; Storms, Gert; Fias, Wim; Wiersema, Jan R.; Van Hulle, Marc M.
2014-01-01
This study examines the influence of a button response task on the event-related potential (ERP) in a semantic priming experiment. Of particular interest is the N400 component. In many semantic priming studies, subjects are asked to respond to a stimulus as fast and accurately as possible by pressing a button. Response time (RT) is recorded in parallel with an electroencephalogram (EEG) for ERP analysis. In this case, the response occurs in the time window used for ERP analysis and response-related components may overlap with stimulus-locked ones such as the N400. This has led to a recommendation against such a design, although the issue has not been explored in depth. Since studies keep being published that disregard this issue, a more detailed examination of influence of response-related potentials on the ERP is needed. Two experiments were performed in which subjects pressed one of two buttons with their dominant hand in response to word-pairs with varying association strength (AS), indicating a personal judgement of association between the two words. In the first experiment, subjects were instructed to respond as fast and accurately as possible. In the second experiment, subjects delayed their button response to enforce a one second interval between the onset of the target word and the button response. Results show that in the first experiment a P3 component and motor-related potentials (MRPs) overlap with the N400 component, which can cause a misinterpretation of the latter. In order to study the N400 component, the button response should be delayed to avoid contamination of the ERP with response-related components. PMID:24516556
Exploring Virtual Worlds with Head-Mounted Displays
1989-02-01
docking problem is important both to biochemists attempting to understand how proteins and nucleic acids work, and to chemists doing analytic drug design...then depressing the mouse button he is able to manipulate the methotrexate. A. long as the mouse button is depressed the methotrexate will follow the... depressing the mouse button outside of the drug’s "grabbing" volume. In this mode, both molecules move in concert. When the active site is positioned to
The floor effect: impoverished spatial memory for elevator buttons.
Vendetti, Michael; Castel, Alan D; Holyoak, Keith J
2013-05-01
People typically remember objects to which they have frequently been exposed, suggesting that memory is a by-product of perception. However, prior research has shown that people have exceptionally poor memory for the features of some objects (e.g., coins) to which they have been exposed over the course of many years. Here, we examined how people remember the spatial layout of the buttons on a frequently used elevator panel, to determine whether physical interaction (rather than simple exposure) would ensure the incidental encoding of spatial information. Participants who worked in an eight-story office building displayed very poor recall for the elevator panel but above-chance performance on a recognition test. Performance was related to how often and how recently the person had used the elevator. In contrast to their poor memory for the spatial layout of the elevator buttons, most people readily recalled small distinctive graffiti on the elevator walls. In a more implicit test, the majority were able to locate their office floor and the eighth floor button when asked to point toward these buttons when in the actual elevator, with the button labels covered. However, identification was very poor for other floors (including the first floor), suggesting that even frequent interaction with information does not always lead to accurate spatial memory. These findings have implications for understanding the complex relationships among attention, expertise, and memory.
Drying kinetics and characteristics of combined infrared-vacuum drying of button mushroom slices
NASA Astrophysics Data System (ADS)
Salehi, Fakhreddin; Kashaninejad, Mahdi; Jafarianlari, Ali
2017-05-01
Infrared-vacuum drying characteristics of button mushroom ( Agaricus bisporus) were evaluated in a combined dryer system. The effects of drying parameters, including infrared radiation power (150-375 W), system pressure (5-15 kPa) and time (0-160 min) on the drying kinetics and characteristics of button mushroom slices were investigated. Both the infrared lamp power and vacuum pressure influenced the drying time of button mushroom slices. The rate constants of the nine different kinetic's models for thin layer drying were established by nonlinear regression analysis of the experimental data which were found to be affected mainly by the infrared power level while system pressure had a little effect on the moisture ratios. The regression results showed that the Page model satisfactorily described the drying behavior of button mushroom slices with highest R value and lowest SE values. The effective moisture diffusivity increases as power increases and range between 0.83 and 2.33 × 10-9 m2/s. The rise in infrared power has a negative effect on the ΔE and with increasing in infrared radiation power it was increased.
Graphical User Interface for a Remote Medical Monitoring System: U.S. Army Medic Recommendations
2009-11-01
screens. The majority of medics (70%) also wanted a name lis! screen that, when tapped , would go to an individual patient screen. In the name list...button has been pushed. Tapping on thaI button would prompt the user to enter the password. Tapping on the light button would illuminate the screen...a summary of current local weather conditions would be dis- played in the lower ! eft of the screen. In the lower right of this map screen is
Characteristics of Useful and Practical Organizational Strategic Plans
ERIC Educational Resources Information Center
Kaufman, Roger
2014-01-01
Most organizational strategic plans are not strategic but rather tactical or operational plans masquerading as "strategic." This article identifies the basic elements required in a useful and practical strategic plan and explains why they are important.
Takeda, Akihiro; Ito, Hiroaki; Nakamura, Hiromi
2017-12-01
Omental cystic lymphangioma is an extremely rare abdominal mass caused by congenital malformation. An 8-year-old premenarchal girl reported abdominal pain. Diagnostic imaging revealed a large multicystic mass measuring 22 cm in diameter, which occupied the entire abdominal cavity with ascites. Emergency laparoscopy revealed a ruptured large cystic mass originating from the greater omentum; this was followed by successful laparoscopic-assisted excision. The pathological diagnosis was omental cystic lymphangioma. The present findings show that omental cystic lymphangioma masquerading as mucinous ovarian neoplasia was a rare cause of acute abdominal events in a young girl. The present case shows that minimally invasive surgery can be a feasible option, which might achieve a favorable outcome in a young patient with an omental cystic lymphangioma. Copyright © 2017 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.
High current capacity electrical connector
Bettis, Edward S.; Watts, Harry L.
1976-01-13
An electrical connector is provided for coupling high current capacity electrical conductors such as copper busses or the like. The connector is arranged in a "sandwiched" configuration in which a conductor plate contacts the busses along major surfaces thereof clamped between two stainless steel backing plates. The conductor plate is provided with a plurality of contact buttons affixed therein in a spaced array such that the caps of the buttons extend above the conductor plate surface to contact the busses. When clamping bolts provided through openings in the sandwiched arrangement are tightened, Belleville springs provided under the rim of each button cap are compressed and resiliently force the caps into contact with the busses' contacting surfaces to maintain a predetermined electrical contact area provided by the button cap tops. The contact area does not change with changing thermal or mechanical stresses applied to the coupled conductors.
Button fixation technique for Achilles tendon reinsertion: a biomechanical study.
Awogni, David; Chauvette, Guillaume; Lemieux, Marie-Line; Balg, Frédéric; Langelier, Ève; Allard, Jean-Pascal
2014-01-01
Chronic insertional tendinopathy of the Achilles tendon is a frequent and disabling pathologic entity. Operative treatment is indicated for patients for whom nonoperative management has failed. The treatment can consist of the complete detachment of the tendon insertion and extensive debridement. We biomechanically tested a new operative technique that uses buttons for fixation of the Achilles tendon insertion on the posterior calcaneal tuberosity and compared it with 2 standard bone anchor techniques. A total of 40 fresh-frozen cadaver specimens were used to compare 3 fixation techniques for reinserting the Achilles tendon: single row anchors, double row anchors, and buttons. The ultimate loads and failure mechanisms were recorded. The button assembly (median load 764 N, range 713 to 888) yielded a median fixation strength equal to 202% (range 137% to 251%) of that obtained with the double row anchors (median load 412 N, range 301 to 571) and 255% (range 213% to 317%) of that obtained with the single row anchors (median load 338 N, range 241 to 433N). The most common failure mechanisms were suture breakage with the buttons (55%) and pull out of the implant with the double row (70%) and single row (85%) anchors. The results of the present biomechanical cadaver study have shown that Achilles tendon reinsertion fixation using the button technique provides superior pull out strength than the bone anchors tested. Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
An EOG-Based Human-Machine Interface for Wheelchair Control.
Huang, Qiyun; He, Shenghong; Wang, Qihong; Gu, Zhenghui; Peng, Nengneng; Li, Kai; Zhang, Yuandong; Shao, Ming; Li, Yuanqing
2017-07-27
Non-manual human-machine interfaces (HMIs) have been studied for wheelchair control with the aim of helping severely paralyzed individuals regain some mobility. The challenge is to rapidly, accurately and sufficiently produce control commands, such as left and right turns, forward and backward motions, acceleration, deceleration, and stopping. In this paper, a novel electrooculogram (EOG)-based HMI is proposed for wheelchair control. Thirteen flashing buttons are presented in the graphical user interface (GUI), and each of the buttons corresponds to a command. These buttons flash on a one-by-one manner in a pre-defined sequence. The user can select a button by blinking in sync with its flashes. The algorithm detects the eye blinks from a channel of vertical EOG data and determines the user's target button based on the synchronization between the detected blinks and the button's flashes. For healthy subjects/patients with spinal cord injuries (SCIs), the proposed HMI achieved an average accuracy of 96.7%/91.7% and a response time of 3.53 s/3.67 s with 0 false positive rates (FPRs). Using only one channel of vertical EOG signals associated with eye blinks, the proposed HMI can accurately provide sufficient commands with a satisfactory response time. The proposed HMI provides a novel non-manual approach for severely paralyzed individuals to control a wheelchair. Compared with a newly established EOG-based HMI, the proposed HMI can generate more commands with higher accuracy, lower FPR and fewer electrodes.
Novel method to avoid the open-sky condition in penetrating keratoplasty: covered cornea technique.
Arslan, Osman S; Unal, Mustafa; Arici, Ceyhun; Cicik, Erdoğan; Mangan, Serhat; Atalay, Eray
2014-09-01
The aim of this study was to present a novel technique to avoid the open-sky condition in pediatric and adult penetrating keratoplasty (PK). Seventy-two eyes of 65 infants and children and 44 eyes of 44 adult patients were operated on using this technique. After trephining the recipient cornea up to a depth of 50% to 70%, the anterior chamber was entered at 1 point. Then, only a 2 clock hour segment of the recipient button was incised, and this segment was sutured to the recipient rim with a single tight suture. The procedure was repeated until the entire recipient button was excised and resutured. The donor corneal button was sutured to the recipient corneal rim. The sutures between the recipient button and the rim were then cut off, and the recipient button was drawn out. None of the patients operated on with this technique developed complications related to the open-sky condition. Visual acuities, graft failure rates, and endothelial cell loss were comparable with the findings of studies performed for conventional PK. The technique described avoids the open-sky condition during the entire PK procedure. Endothelial cell loss rates are acceptable.
Surgical treatment of pectoralis major muscle rupture with adjustable cortical button.
Pochini, Alberto de Castro; Rodrigues, Marcus de Souza Barbosa; Yamashita, Larissa; Belangero, Paulo Santoro; Andreoli, Carlos Vicente; Ejnisman, Benno
2018-01-01
To assess the tendon reconstruction technique for total rupture of the pectoralis major muscle using an adjustable cortical button. Prospective study of 27 male patients with a mean age of 29.9 (SD = 5.3 years) and follow-up of 2.3 years. The procedure consisted of autologous grafts taken from the semitendinosus and gracilis tendons and an adjustable cortical button. Patients were evaluated functionally by the Bak criteria. The surgical treatment of pectoralis major muscle tendon reconstruction was performed in the early stages (three weeks) in six patients (22.2%) and in 21 patients (77.8%), in the late stages. Patients operated with the adjustable cortical button technique obtained 96.3% excellent or good results, with only 3.7% having poor results (Bak criteria). Of the total, 85.2% were injured while performing bench press exercises and 14.8%, during the practice of Brazilian jiu-jitsu or wrestling. All weight-lifting athletes had history of anabolic steroid use. The early or delayed reconstruction of ruptured pectoralis major muscle tendons with considerable muscle retraction, using an adjustable cortical button and autologous knee flexor grafts, showed a high rate of good results.
[Autoshaping of a button-push response and eye movement in human subjects].
Kimura, H; Fukui, I; Inaki, K
1990-12-01
Two experiments were conducted with human subjects to investigate the similarities and differences between animal and human behaviors under autoshaping procedures. In these experiments, light served as CS, and display on TV served as US. Whether the pushing button response or gazing response to CS could be obtained in human subjects under Pavlovian conditioning procedure was examined. In Experiment 1, uninstructed naive subjects were placed in a room containing a push-button and a TV display. Within the experimental sessions, the push-button was lit for 8 s as CS, and then paired with the display of a soft pornographic program on TV for 10 s. The result indicated that the modeling of pushing button promoted the increase of response probability among the subjects. The trials conducted after the rest period indicated an increase of response probability. In Experiment 2, a 4 cm square translucent panel was lit for 20 s as CS, and then paired with the display of a computer graphic picture on TV for 8 s as US. Some subjects started gazing at the CS for several seconds. These results indicated that some subjects could acquire the gazing response under the autoshaping procedure.
A Wearable Hydration Sensor with Conformal Nanowire Electrodes.
Yao, Shanshan; Myers, Amanda; Malhotra, Abhishek; Lin, Feiyan; Bozkurt, Alper; Muth, John F; Zhu, Yong
2017-03-01
A wearable skin hydration sensor in the form of a capacitor is demonstrated based on skin impedance measurement. The capacitor consists of two interdigitated or parallel electrodes that are made of silver nanowires (AgNWs) in a polydimethylsiloxane (PDMS) matrix. The flexible and stretchable nature of the AgNW/PDMS electrode allows conformal contact to the skin. The hydration sensor is insensitive to the external humidity change and is calibrated against a commercial skin hydration system on an artificial skin over a wide hydration range. The hydration sensor is packaged into a flexible wristband, together with a network analyzer chip, a button cell battery, and an ultralow power microprocessor with Bluetooth. In addition, a chest patch consisting of a strain sensor, three electrocardiography electrodes, and a skin hydration sensor is developed for multimodal sensing. The wearable wristband and chest patch may be used for low-cost, wireless, and continuous monitoring of skin hydration and other health parameters. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Recurrent and acquired tracheoesophageal fistulae (TEF)-Minimally invasive management.
Nazir, Zafar; Khan, Muhammad Arif Mateen; Qamar, Javaria
2017-10-01
Recurrent and acquired fistulae are a serious complication of congenital esophageal atresia and tracheoesophageal fistula (TEF) repair and foreign body ingestion (FBI) (e.g., button battery). We report our experience with a minimally invasive approach to recurrent and acquired TEF. Medical records of patients referred for management of recurrent and acquired TEF between 2003 and 2015 were reviewed retrospectively. Patients underwent endoscopic procedures (de-epithelization of fistulous tract and fibrin tissue adhesive-Tisseel R ) under general anesthesia. Nine children (7 male, 2 female) with age range 3months to 3years (mean 1.5year) were managed. TEF closed spontaneously in four patients, whereas in 5 patients the TEF closed after combined endoscopic procedure. Three patients required repeat endoscopic procedures. Follow-up ranged between 7months to 10years (mean 4.2years). Active observation and repeat combined endoscopic procedures are safe alternatives to open surgical repair of acquired and recurrent TEF. Level IV study. Copyright © 2017 Elsevier Inc. All rights reserved.
A portable wireless power transmission system for video capsule endoscopes.
Shi, Yu; Yan, Guozheng; Zhu, Bingquan; Liu, Gang
2015-01-01
Wireless power transmission (WPT) technology can solve the energy shortage problem of the video capsule endoscope (VCE) powered by button batteries, but the fixed platform limited its clinical application. This paper presents a portable WPT system for VCE. Besides portability, power transfer efficiency and stability are considered as the main indexes of optimization design of the system, which consists of the transmitting coil structure, portable control box, operating frequency, magnetic core and winding of receiving coil. Upon the above principles, the correlation parameters are measured, compared and chosen. Finally, through experiments on the platform, the methods are tested and evaluated. In the gastrointestinal tract of small pig, the VCE is supplied with sufficient energy by the WPT system, and the energy conversion efficiency is 2.8%. The video obtained is clear with a resolution of 320×240 and a frame rate of 30 frames per second. The experiments verify the feasibility of design scheme, and further improvement direction is discussed.
Review of foreign body ingestion and esophageal food impaction management in adolescents.
Sahn, Benjamin; Mamula, Petar; Ford, Carol A
2014-08-01
Foreign body ingestion is a common clinical scenario among patients of all ages. The immediate risk to the patient ranges from negligible to life threatening. Initial and follow-up management strategies depend on multiple patient and ingested object-related factors. Available literature on this topic tends to focus on the small child or adult, leaving the clinician caring for adolescents to extrapolate this information to guide decision making for individual patients. This article reviews foreign body ingestion literature with important implications to the adolescent patient and raises awareness of some highly dangerous objects such as large button batteries, high-powered magnets, long sharps, narcotic packages, and super absorbent objects. An additional focus includes the management of esophageal food impaction. We highlight the unique aspects to the care of the adolescent with intentional ingestion and co-morbid psychiatric illness. The article concludes by discussing the challenges to prevention of ingestion in the at-risk patient. Copyright © 2014 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.
Personal graphical communicator.
Stephens, Michael; Barrett, Steven
2008-01-01
A device to help a child communicate was requested by an educator. The child cannot read, write, or speak but can recognize symbols and use those symbols to communicate. While this communication works, it doesn't work well in situations where another person does not know how to use the symbols to communicate. For this reason, a device was requested that could display images to a child and play a phrase when that image was chosen. To meet this need an MP3 player like device was constructed. The device stores images and Mpeg-Layer III (MP3) sound clips on a replaceable Secure Digital (SD) card. The images are displayed on a color Liquid Crystal Display (LCD) where the user is able to skip through images to find the phrase that needs to be said. Once found simply hitting the play button will play the sound clip associated with the image. The device is portable and compact for easy use. It uses Universal Serial Bus (USB) to recharge its batteries, communicate with the PC and update the firmware.
When Waves Collide: Future Conflict
1995-01-01
predictions merely guesswork, and forecasts often nothing more than co- herent fiction masquerading as fact.2 Trends and megatrends , which are linear...transportation, on-site inspection, and environmental cleanup—including radi- ological, chemical, and biological —as well as enforcement of the
Soft robot design methodology for `push-button' manufacturing
NASA Astrophysics Data System (ADS)
Paik, Jamie
2018-06-01
`Push-button' or fully automated manufacturing would enable the production of robots with zero intervention from human hands. Realizing this utopia requires a fundamental shift from a sequential (design-materials-manufacturing) to a concurrent design methodology.
MedlinePlus FAQ: Disease or Condition Information
... on the Health Topics button on the MedlinePlus homepage. You can also find the Health Topics button ... MedlinePlus Connect for EHRs For Developers U.S. National Library of Medicine 8600 Rockville Pike, Bethesda, MD 20894 ...
Development of non-keyboard input device checklists through assessments.
Woods, Valerie; Hastings, Sarah; Buckle, Peter; Haslam, Roger
2003-11-01
An assessment of non-keyboard input devices (NKID) was conducted to identify factors for good design in relation to operation, performance and comfort. Twenty-seven NKID users, working in health and safety, evaluated eight devices that included mice, trackballs and a joystick mouse. The factors considered important for good design were: (1) comfortable hand and finger position, (2) adequate control, (3) intuitive and easy to use, (4) ease of device, button and trackball movement, (5) good interaction with software, (6) provision of suitable accessories. Mice were rated more favourably than trackballs or the joystick mouse. The design of the standard 2-button mouse (D4) was considered most desirable to use; the 3-button mouse (D1) and 3-button curved mouse (D8) were also favoured. Assessment data and comments were drawn together with previously published research to produce useful tools for NKID purchasing (i.e. Device Purchasing Checklist) and assessment (i.e. Device Assessment Checklist).
Goodman, Alice E; Carmichael, Daniel T
2016-03-01
Maxillofacial trauma in cats often results in mandibular symphyseal separation in addition to injuries of the caudal mandible and/or temporomandibular joint (TMJ). Caudal mandibular and TMJ injuries are difficult to access and stabilize using direct fixation techniques, thus indirect fixation is commonly employed. The immediate goals of fixation include stabilization for return to normal occlusion and function with the long-term objective of bony union. Indirect fixation techniques commonly used for stabilization of caudal mandibular and temporomandibular joint fracture/luxation include maxillomandibular fixation (MMF) with acrylic composite, interarcade wiring, tape muzzles, and the bignathic encircling and retaining device (BEARD) technique. This article introduces a modification of the previously described "labial reverse suture through buttons" technique used by Koestlin et al and the "labial locking with buttons" technique by Rocha et al. In cases with minimally displaced subcondylar and pericondylar fractures without joint involvement, the labial button technique can provide sufficient stabilization for healing. Advantages of the modified labial button technique include ease of application, noninvasive nature, and use of readily available materials. The construct can remain in place for a variable of amount of time, depending on its intended purpose. It serves as an alternative to the tape muzzle, which is rarely tolerated by cats. This technique can be easily used in conjunction with other maxillomandibular repairs, such as cerclage wire fixation of mandibular symphyseal separation. The purpose of this article is to demonstrate a modified labial button technique for maintaining occlusion of feline caudal mandibular fractures/TMJ luxations in a step-by-step fashion.
Alkis, Huseyin; Turkkahraman, Hakan
2013-01-01
Objective To evaluate the effects of contamination by either blood or a hemostatic agent on the shear bond strength (SBS) of orthodontic buttons. Methods We used 45 freshly extracted, non-carious, impacted third molars that were divided into 3 groups of 15. Each tooth was etched with 37% phosphoric acid gel for 30 s. Human blood or the blood stopper agent was applied to the tooth surface in groups I and II, respectively. Group III teeth were untreated (controls). Orthodontic buttons were bonded to the teeth using light-curing composite resin. After bonding, the SBS of the button was determined using a Universal testing machine. Any adhesive remaining after debonding was assessed and scored according to the modified adhesive remnant index (ARI). ANOVA with post-hoc Tukey's test was used to determine significant differences in SBS and Fisher's exact test, to determine significant differences in ARI scores among groups. Results ANOVA indicated a significant difference between groups (p < 0.001). The highest SBS values were measured in group III (10.73 ± 0.96 MPa). The SBS values for teeth in groups I and II were significantly lower than that of group III (p < 0.001). The lowest SBS values were observed in group I teeth (4.17 ± 1.11 MPa) (p < 0.001). Conclusions Contamination of tooth surfaces with either blood or hemostatic agent significantly decreased the SBS of orthodontic buttons. When the contamination risk is high, it is recommended to use the blood stopper agent when bonding orthodontic buttons on impacted teeth. PMID:23671834
Hasselberg, Michael J; McMahon, James; Parker, Kathy
2013-01-01
Changes in core body temperature due to heat transfer through the skin have a major influence on sleep regulation. Traditional measures of skin temperature are often complicated by extensive wiring and are not practical for use in normal living conditions. This review describes studies examining the reliability, validity and utility of the iButton®, a wireless peripheral thermometry device, in sleep/wake research. A review was conducted of English language literature on the iButton as a measure of circadian body temperature rhythms associated with the sleep/wake cycle. Seven studies of the iButtton as a measure of human body temperature were included. The iButton was found to be a reliable and valid measure of body temperature. Its application to human skin was shown to be comfortable and tolerable with no significant adverse reactions. Distal skin temperatures were negatively correlated with sleep/wake activity, and the temperature gradient between the distal and proximal skin (DPG) was identified as an accurate physiological correlate of sleep propensity. Methodological issues included site of data logger placement, temperature masking factors, and temperature data analysis. The iButton is an inexpensive, wireless data logger that can be used to obtain a valid measurement of human skin temperature. It is a practical alternative to traditional measures of circadian rhythms in sleep/wake research. Further research is needed to determine the utility of the iButton in vulnerable populations, including those with neurodegenerative disorders and memory impairment and pediatric populations. Copyright © 2011 Elsevier B.V. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-13
... fragments, 29 historic ceramic sherds, 1 prehistoric ceramic sherd, 128 unmodified faunal bone fragments, 1 modified deer rib, 3 bone buttons, 4 chipped stone flakes, 2 wooden buttons, 1 historic clay pipe bowl...
NASA Technical Reports Server (NTRS)
Williams, D.
1976-01-01
Test were conducted to determine whether differences in speed and accuracy are experienced when using either line-labeled index buttons or a numeric keyboard for page selection in airborne CRT-display area navigation systems. The experiment was conducted with six airline pilots, each flying the same two simulated RNAV routes. Three pilot subjects used line-labeled buttons adjacent to the CRT screen, while three used a numeric keyboard for page access. The hypothesis of no differences in response times between the two modes of access could not be rejected.
Susceptibility of ornamental pepper banker plant candidates to common greenhouse pests
USDA-ARS?s Scientific Manuscript database
Susceptibility of four potential ornamental pepper banker plant candidates [Black Pearl (BP), Explosive Ember (EE), Masquerade (MA), Red Missile (RM), and a commercial pepper cultivar Blitz (BL)] were evaluated against three common greenhouse pests - Bemisia tabaci, Polyphagotarsonemus latus and Fra...
Granuloma fissuratum masquerading as a skin tumor.
Rist, T E; Marks, J G
1980-06-01
Granuloma fissuratum is a reactive process of the skin usually caused by chronic trauma from ill-fitting eyeglass frames. Its clinical resemblance to malignant tumors makes it important to recognize this benign condition. This case report discuses the diagnosis and management of granuloma fissuratum.
Genomic analysis identifies masqueraders of full-term cerebral palsy.
Takezawa, Yusuke; Kikuchi, Atsuo; Haginoya, Kazuhiro; Niihori, Tetsuya; Numata-Uematsu, Yurika; Inui, Takehiko; Yamamura-Suzuki, Saeko; Miyabayashi, Takuya; Anzai, Mai; Suzuki-Muromoto, Sato; Okubo, Yukimune; Endo, Wakaba; Togashi, Noriko; Kobayashi, Yasuko; Onuma, Akira; Funayama, Ryo; Shirota, Matsuyuki; Nakayama, Keiko; Aoki, Yoko; Kure, Shigeo
2018-05-01
Cerebral palsy is a common, heterogeneous neurodevelopmental disorder that causes movement and postural disabilities. Recent studies have suggested genetic diseases can be misdiagnosed as cerebral palsy. We hypothesized that two simple criteria, that is, full-term births and nonspecific brain MRI findings, are keys to extracting masqueraders among cerebral palsy cases due to the following: (1) preterm infants are susceptible to multiple environmental factors and therefore demonstrate an increased risk of cerebral palsy and (2) brain MRI assessment is essential for excluding environmental causes and other particular disorders. A total of 107 patients-all full-term births-without specific findings on brain MRI were identified among 897 patients diagnosed with cerebral palsy who were followed at our center. DNA samples were available for 17 of the 107 cases for trio whole-exome sequencing and array comparative genomic hybridization. We prioritized variants in genes known to be relevant in neurodevelopmental diseases and evaluated their pathogenicity according to the American College of Medical Genetics guidelines. Pathogenic/likely pathogenic candidate variants were identified in 9 of 17 cases (52.9%) within eight genes: CTNNB1 , CYP2U1 , SPAST , GNAO1 , CACNA1A , AMPD2 , STXBP1 , and SCN2A . Five identified variants had previously been reported. No pathogenic copy number variations were identified. The AMPD2 missense variant and the splice-site variants in CTNNB1 and AMPD2 were validated by in vitro functional experiments. The high rate of detecting causative genetic variants (52.9%) suggests that patients diagnosed with cerebral palsy in full-term births without specific MRI findings may include genetic diseases masquerading as cerebral palsy.
Identifying and quantifying recurrent novae masquerading as classical novae
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pagnotta, Ashley; Schaefer, Bradley E., E-mail: pagnotta@amnh.org
2014-06-20
Recurrent novae (RNe) are cataclysmic variables with two or more nova eruptions within a century. Classical novae (CNe) are similar systems with only one such eruption. Many of the so-called CNe are actually RNe for which only one eruption has been discovered. Since RNe are candidate Type Ia supernova progenitors, it is important to know whether there are enough in our Galaxy to provide the supernova rate, and therefore to know how many RNe are masquerading as CNe. To quantify this, we collected all available information on the light curves and spectra of a Galactic, time-limited sample of 237 CNemore » and the 10 known RNe, as well as exhaustive discovery efficiency records. We recognize RNe as having (1) outburst amplitude smaller than 14.5 – 4.5 × log (t {sub 3}), (2) orbital period >0.6 days, (3) infrared colors of J – H > 0.7 mag and H – K > 0.1 mag, (4) FWHM of Hα > 2000 km s{sup –1}, (5) high excitation lines, such as Fe X or He II near peak, (6) eruption light curves with a plateau, and (7) white dwarf mass greater than 1.2 M {sub ☉}. Using these criteria, we identify V1721 Aql, DE Cir, CP Cru, KT Eri, V838 Her, V2672 Oph, V4160 Sgr, V4643 Sgr, V4739 Sgr, and V477 Sct as strong RN candidates. We evaluate the RN fraction among the known CNe using three methods to get 24% ± 4%, 12% ± 3%, and 35% ± 3%. With roughly a quarter of the 394 known Galactic novae actually being RNe, there should be approximately a hundred such systems masquerading as CNe.« less
Insertion of Balloon Retained Gastrostomy Buttons: A 5-Year Retrospective Review of 260 Patients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Power, Sarah, E-mail: sarahpower28@yahoo.co.uk; Kavanagh, Liam N.; Shields, Mary C.
Radiologically inserted gastrostomy (RIG) is an established way of maintaining enteral nutrition in patients who cannot maintain nutrition orally. The purpose of this study was to evaluate the safety and efficacy of primary placement of a wide bore button gastrostomy in a large, varied patient population through retrospective review. All patients who underwent gastrostomy placement from January 1, 2004 to January 1, 2009 were identified. 18-Fr gastrostomy buttons (MIC-Key G) were inserted in the majority. Follow-up ranged from 6 months to 4.5 years. A total of 260 patients (M:F 140:120, average age 59.2 years) underwent gastrostomy during the study period.more » Overall success rate for RIG placement was 99.6 %, with success rate of 95.3 % for primary button insertion. Indications included neurological disorders (70 %), esophageal/head and neck malignancy (21 %), and other indications (9 %). Major and minor complication rates were 1.2 and 12.8 %, respectively. Thirty-day mortality rate was 6.8 %. One third of patients underwent gastrostomy reinsertion during the study period, the main indication for which was inadvertent catheter removal. Patency rate was high at 99.5 %. The maximum number of procedures in any patient was 8 (n = 2), and the average tube dwell time was 125 days. Primary radiological insertion of a wide bore button gastrostomy is a safe technique, with high success rate, high patency rate, and low major complication rate. We believe that it is feasible to attempt button gastrostomy placement in all patients, once tract length is within limits of tube length. If difficulty is encountered, then a standard tube may simply be placed instead.« less
Stenzel, Anna; Dolk, Thomas; Colzato, Lorenza S.; Sellaro, Roberta; Hommel, Bernhard; Liepelt, Roman
2014-01-01
A co-actor's intentionality has been suggested to be a key modulating factor for joint action effects like the joint Simon effect (JSE). However, in previous studies intentionality has often been confounded with agency defined as perceiving the initiator of an action as being the causal source of the action. The aim of the present study was to disentangle the role of agency and intentionality as modulating factors of the JSE. In Experiment 1, participants performed a joint go/nogo Simon task next to a co-actor who either intentionally controlled a response button with own finger movements (agency+/intentionality+) or who passively placed the hand on a response button that moved up and down on its own as triggered by computer signals (agency−/intentionality−). In Experiment 2, we included a condition in which participants believed that the co-actor intentionally controlled the response button with a Brain-Computer Interface (BCI) while placing the response finger clearly besides the response button, so that the causal relationship between agent and action effect was perceptually disrupted (agency−/intentionality+). As a control condition, the response button was computer controlled while the co-actor placed the response finger besides the response button (agency−/intentionality−). Experiment 1 showed that the JSE is present with an intentional co-actor and causality between co-actor and action effect, but absent with an unintentional co-actor and a lack of causality between co-actor and action effect. Experiment 2 showed that the JSE is absent with an intentional co-actor, but no causality between co-actor and action effect. Our findings indicate an important role of the co-actor's agency for the JSE. They also suggest that the attribution of agency has a strong perceptual basis. PMID:25140144
Stenzel, Anna; Dolk, Thomas; Colzato, Lorenza S; Sellaro, Roberta; Hommel, Bernhard; Liepelt, Roman
2014-01-01
A co-actor's intentionality has been suggested to be a key modulating factor for joint action effects like the joint Simon effect (JSE). However, in previous studies intentionality has often been confounded with agency defined as perceiving the initiator of an action as being the causal source of the action. The aim of the present study was to disentangle the role of agency and intentionality as modulating factors of the JSE. In Experiment 1, participants performed a joint go/nogo Simon task next to a co-actor who either intentionally controlled a response button with own finger movements (agency+/intentionality+) or who passively placed the hand on a response button that moved up and down on its own as triggered by computer signals (agency-/intentionality-). In Experiment 2, we included a condition in which participants believed that the co-actor intentionally controlled the response button with a Brain-Computer Interface (BCI) while placing the response finger clearly besides the response button, so that the causal relationship between agent and action effect was perceptually disrupted (agency-/intentionality+). As a control condition, the response button was computer controlled while the co-actor placed the response finger besides the response button (agency-/intentionality-). Experiment 1 showed that the JSE is present with an intentional co-actor and causality between co-actor and action effect, but absent with an unintentional co-actor and a lack of causality between co-actor and action effect. Experiment 2 showed that the JSE is absent with an intentional co-actor, but no causality between co-actor and action effect. Our findings indicate an important role of the co-actor's agency for the JSE. They also suggest that the attribution of agency has a strong perceptual basis.
Hammann, Simon; Vetter, Walter
2016-05-04
Ergosterol is the major sterol in button mushrooms (Agaricus bisporus) and can occur as free alcohol or esterified with fatty acids (ergosteryl esters). In this study, gas chromatography with mass spectrometry in the selected ion monitoring mode (GC/MS-SIM) was used to determine ergosterol and ergosteryl esters as well as other sterols and steryl esters in button mushrooms. Different quality control measures were established and sample preparation procedures were compared to prevent the formation of artifacts and the degradation of ergosteryl esters. The final method was then used for the determination of ergosterol (443 ± 44 mg/100 g dry matter (d.m.)) and esterified ergosterol (12 ± 6 mg/100 g d.m.) in button mushroom samples (n = 4). While the free sterol fraction was vastly dominated by ergosterol (∼90% of five sterols in total), the steryl ester fraction was more diversified (nine sterols in total, ergosterol ∼55%) and consisted primarily of linoleic acid esters.
Pei, Fei; Shi, Ying; Gao, Xingyang; Wu, Fangning; Mariga, Alfred Mugambi; Yang, Wenjian; Zhao, Liyan; An, Xinxin; Xin, Zhihong; Yang, Fangmei; Hu, Qiuhui
2014-12-15
Button mushroom slices were dehydrated using freeze drying (FD) or FD combined with microwave vacuum drying (FMVD), and the non-volatile component profiles were studied. The results showed that the level of non-volatile components in button mushroom firstly increased during sublimation of FD/FMVD process and then fell during desorption in FD process and MVD in FMVD process. Compared to FD products, the contents of soluble sugars and polyols in FMVD products were relatively low, whereas the contents of total free amino acids were significantly higher, close to the level of fresh mushroom. However, there was no significant difference in the contents of 5'-nucleotides and organic acids between FD and FMVD products. The equivalent umami concentration (EUC) values for FD and FMVD products did not differ from fresh, indicating that both drying methods could effectively preserve MSG (monosodium glutamate)-like components in button mushroom. Copyright © 2014 Elsevier Ltd. All rights reserved.
Taking Science Seriously in the Debate on Death and Organ Transplantation.
Nair-Collins, Michael
2015-01-01
The effort to develop international guidelines for determination of death purports to start with an objective examination of the biology of death. So far, however, it is showing once again how moral and metaphysical claims about death masquerade as scientific facts.
Selecting an ornamental pepper banker plant for Amblyseius swirskii in floriculture crops
USDA-ARS?s Scientific Manuscript database
Preference of phytoseiid mite Amblyseius swirskii (Athias-Henriot) was assessed on four cultivars of ornamental pepper banker plant candidates; Red Missile (RM), Masquerade (MA), Explosive Ember (EE), and Black Pearl (BP) for potential control of pestiferous insects in floriculture. Cultivar prefere...
A type II first branchial cleft cyst masquerading as an infected parotid Warthin's tumor.
Chen, Meng-Feng; Ueng, Shir-Hwa; Jung, Shih-Ming; Chen, Yao-Liang; Chang, Kai-Ping
2006-01-01
The diagnosis of a parotid mass usually depends on thorough history taking and physical examination. Diagnostic modalities, including ultrasonographic examinations, computed tomography and magnetic resonance images, may also provide substantial information but their accuracy for diagnosis is sometimes questionable, especially in differentiating some rare neoplasms. First branchial cleft cysts (FBCCs) are rare causes of parotid swelling and comprise less than 1% of all branchial anomalies. They are frequently misdiagnosed due to their rarity and unfamiliar clinical signs and symptoms. We present a case of type II FBCC masquerading as an infected parotid Warthin's tumor. We also review the clinical signs and symptoms of FBCCs in order to remind clinicians that this rare branchial anomaly can mimic an infected Warthin's tumor and may be seated in the deep lobe of the parotid gland. By making an accurate pre-operative diagnosis of type II FBCC, we can minimize surgical morbidity and avoid incomplete resection and possible recurrence.
Choi, Eun-Kyoung; Kim, Wan-Ho
2006-01-01
Composite adrenal medullary tumors, composed of both pheochromocytoma and ganglioneuroma, are extremely rare, as are pheochromocytomas masquerading as acute relapsing pancreatitis. We recently experienced a case of a 48-year-old male with both these phenomena. The patient complained of an acute onset of intense abdominal discomfort. At the same time, pancreatic enzymes were increased in concentration. An abdominal computed tomographic scan revealed an enlarged pancreas and a 3-cm left adrenal incidentaloma. Biochemical and 131I-MIBG scintigraphic findings were compatible with a pheochromocytoma. Yet, he had no clinical manifestations suggesting pheochromocytoma. An adrenalectomy was performed and a composite adrenal medullary tumor of pheochromocytoma and ganglioneuroma was confirmed during a pathologic examination. This case illustrates two points: 1) acute abdominal intense discomfort and hyperamylasemia may be unusual presentations of pheochromocytomas; and 2) the possibility of the pheochromocytoma, albeit rare, should be considered when a relapsing pancreatitis of uncertain etiology develops. PMID:16913447
Schwannoma of the descending loop of the hypoglossal nerve: Case report.
Illuminati, Giulio; Pizzardi, Giulia; Pasqua, Rocco; Palumbo, Piergaspare; Vietri, Francesco
2017-01-01
Schwannomas of the descending loop of the hypoglossal nerve are very rare. They are slow-growing tumors that may masquerade a carotid body tumor. A 60-year-old female was referred for a latero-cervical mass appearing as a chemodectoma at CT-scan. At operation, a 2cm mass arising from the descending loop of the hypoglossal nerve was resected en bloc with the loop itself and a functional lymphadenectomy was associated. Post-operative course was uneventful and the patient is free from disease recurrence at one year follow-up. En bloc resection remains the real curative treatment of Schwannomas, ensuring unlimited freedom from disease, although causing functional impairment which may be significant. Nonetheless recurrence should be prevented as, beside requiring reintervention, it may harbor a malignant evolution towards sarcoma. Schwannomas of the descending lop of the hypoglossal nerve may masquerade a chemodectoma of the carotid bifurcation and can be curatively resected without any functional impairment. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Primary hyperparathyroidism may masquerade as rickets-osteomalacia in vitamin D replete children.
Ganie, Mohd Ashraf; Raizada, Nishant; Chawla, Himika; Singh, Arun Kumar; Aggarwala, Sandeep; Bal, Chandra Sekhar
2016-10-01
Primary hyperparathyroidism, typically a disease of the middle aged and the old, is less commonly seen in children. In children the disease has a bimodal age distribution with calcium sensing receptor mutation presenting in infancy as hypercalcemic crises and parathyroid adenoma or hyperplasia presenting later in childhood with bone disease. The childhood parathyroid adenomas are often familial with multiglandular disease and manifest with severe bone disease unlike adults. We report a series of four male patients with juvenile primary hyperparathyroidism, three of whom presented with bone disease masquerading as rickets-osteomalacia. One patient had asymptomatic hypercalcemia with short stature. Parathyroid adenoma was detected in all the four cases and all of them underwent resection of parathyroid adenomas confirmed on histopathology. Post-surgery all the cases had initial hypocalcaemia followed by normocalcemia. One case developed pancreatitis after surgery even after achieving normocalcemia. We conclude that parathyroid adenomas, although uncommon in children, are an important cause of skeletal disease that may initially be confused with hypovitaminosis D.
Nail psoriasis masqueraded by secondary infection with Rhodotorula mucilaginosa.
Martini, K; Müller, H; Huemer, H P; Höpfl, R
2013-11-01
A 38-year-old man presented with whitish nail changes on all fingers as the sole symptom. The condition had developed within a few days and led to dystrophy of the proximal part of the nail plates. As microscopic examination of nail scrapings demonstrated budding hyphae and the patient working as a teacher reported frequent use of a wet sponge, antifungal therapy was initiated. Subsequent cultures and molecular typing identified Rhodotorula mucilaginosa (formerly R. rubra). This environmental yeast was repeatedly isolated despite of therapy with itraconazole. As no improvement was achieved and testing of the biological activity of the fungus revealed only marginal keratolytic activity, it was considered as a coloniser of a destructed nail matrix. Finally, a biopsy of the nail bed confirmed the diagnosis of nail psoriasis, which rapidly responded to treatment with acitretin and topical calcipotriol/betamethasone cream. Fungal growth in destructed nails masqueraded the underlying disease and may have triggered the psoriatic nail reaction. © 2013 Blackwell Verlag GmbH.
Experimental analysis of surface finish in normal conducting cavities
NASA Astrophysics Data System (ADS)
Zarrebini-Esfahani, A.; Aslaninejad, M.; Ristic, M.; Long, K.
2017-10-01
A normal conducting 805 MHz test cavity with an in built button shaped sample is used to conduct a series of surface treatment experiments. The button enhances the local fields and influences the likelihood of an RF breakdown event. Because of their smaller sizes, compared to the whole cavity surface, they allow practical investigations of the effects of cavity surface preparation in relation to RF breakdown. Manufacturing techniques and steps for preparing the buttons to improve the surface quality are described in detail. It was observed that even after the final stage of the surface treatment, defects on the surface of the cavities still could be found.
Key Aroma Compounds in Lippia dulcis (Dushi Button).
Schmitt, Rainer; Cappi, Michael; Pollner, Gwendola; Greger, Veronika
2018-03-14
An aroma extract dilution analysis (AEDA) applied on aroma extracts prepared from the edible flower Dushi Button ( Lippia dulcis) resulted in the detection of 34 odor-active compounds. The highest flavor dilution (FD) factors were determined for methyl 2-methylbutanoate, ethyl 2-methylbutanoate, 4-mercapto-4-methyl-2-pentanone, an unknown caramel-like compound, and vanillin. Quantitative measurements performed by application of stable isotope dilution assays (SIDA), followed by a calculation of odor activity values (OAVs), resulted in the revelation of 4-mercapto-4-methyl-2-pentanone, linalool, myrcene, ethyl 2-methylbutanoate, methyl 2-methylbutanoate, and ( Z)-3-hexenal as important contributors to the flavor of Dushi Buttons.
NASA Astrophysics Data System (ADS)
Akyuz, Sevim; Akyuz, Tanil; Cakan, Banu; Basaran, Sait
2014-09-01
Some metal ornamented textile specimens and a textile button, excavated from Ancient Ainos (Enez - Turkey), have been investigated using FTIR and EDXRF spectrometry, for the purpose of material identification. FTIR spectral results indicated that textiles were made from partially degummed Bombyx mori silk. The IR spectral investigation of the textile button revealed that some cellulose fillings were used inside the button. The EDXRF analysis of the metal ornaments showed that they were silver plated copper. Surface morphology of the textiles and the metal ornaments were investigated by SEM images. It was shown that textile fibers were highly degraded.
Armpits, Belly Buttons and Chronic Wounds: The ABCs of Our Body Bacteria
... Wounds: The ABCs of Our Body Bacteria Inside Life Science View All Articles | Inside Life Science Home Page Armpits, Belly Buttons and Chronic Wounds: ... Other Findings About Our Resident Microbes This Inside Life Science article also appears on LiveScience . Learn about related ...
Harper, Martin; Muller, Brian S
2002-10-01
In 1998 the American Conference for Governmental Industrial Hygienists (ACGIH) proposed size selective sampling for wood dust based on the inhalable fraction. Thus the proposed threshold limit values (TLVs) require the use of a sampler whose performance matches the inhalable convention. The Institute of Occupational Medicine (IOM) sampler has shown good agreement with the inhalable convention under controlled conditions, and the Button sampler, developed by the University of Cincinnati, has shown reasonable agreement in at least one laboratory study. The Button sampler has not been previously evaluated under wood working conditions, and the IOM has been shown to sample more mass than expected when compared to the standard closed-face cassette, which may be due to the collection of very large particles in wood working environments. Some projectile particles may be > 100 microm aerodynamic diameter and thus outside the range of the convention. Such particles, if present, can bias the estimates of concentration considerably. This study is part of an on-going research focus into selecting the most appropriate inhalable sampler for use in these industries, and to examine the impact of TLV changes. This study compared gravimetric analyses (National Institute of Occupational Safety and Health Method 0500) of side-by-side personal samples using the Button, IOM, and 37 mm closed-face cassette (CFC) under field-use conditions. A total of 51 good sample pairs were collected from three wood products industries involved in the manufacturing of cabinets, furniture, and shutters. Paired t-tests were run on each sample pair using Statistical Package for the Social Sciences (SPSS) version 10. The IOM and the CFC measured statistically different concentrations (p < 0.0005, n = 16). The IOM and Button measured statistically different concentrations (p = 0.020, n = 12). The Button and CFC did not measure statistically different concentrations of wood dust (p = 0.098, n = 23). Sampler ratios for IOM/CFC pairs ranged from 1.19-19 (median 3.35). Sampler ratios for IOM/Button pairs ranged from 0.49-163 (median 3.15). Sampler ratios for CFC/Button pairs ranged from 0.36-27 (median 1.2). In all cases, higher ratios were associated with higher concentrations. The median relative difference between the IOM's and CFC's is in accord with prior field studies in woodworking environments, and, taken together, the data imply a conversion factor greater than the 2.5 normally applied to CFC results to approximate inhalable values, as measured by the IOM. Raising the limit values by approximately 50% appears warranted for this particular situation of inhalable wood dust measured by the IOM. The IOM/Button and CFC/Button ratios were unexpectedly low, which may be due to the exclusion of very large particles, collected by the IOM and CFC samplers. Further work is required to explain these results.
78 FR 32081 - Airworthiness Directives; Aircraft Industries a.s. Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-29
... Injection System WATER INJECTION circuit ON breakter. TCL TQ=min. 60% WATER INJECTION/ON push- Push and hold till amber button. WATER INJECTION signal comes on (on the front control panel) Before throttling back power: WATER INJECTION/OFF push- Push and check amber button. WATER INJECTION signal extinguishes...
Adapting the eButton to the abilities of children for diet assessment
USDA-ARS?s Scientific Manuscript database
Dietary assessment is fraught with error among adults and especially among children. Innovative technology may provide more accurate assessments of dietary intake. One recently available innovative method is a camera worn on the chest (called an eButton) that takes images of whatever is in front of ...
USDA-ARS?s Scientific Manuscript database
We previously showed that dietary white button mushrooms (WBM) enhanced natural killer cell activity and that in vitro WBM supplementation promotes maturation and function of dendritic cells (DC). The current study investigated whether WBM consumption would enhance pathogen-specific immune response ...
. solarsystem mobile thumbnail solarystem mobile button Webb will monitor the weather and atmospheres of the mobile thumbnail exoplanets-weather mobile button Webb will search for signs of life-sustaining water on planets beyond our solar system, and help us learn how planets form. blackholes mobile thumbnail
ERIC Educational Resources Information Center
Johnson, Vesta
In the Haida nation, there are two phratries, Eagle and Raven, divided into a number of clans sharing one or more emblems. These emblems, inherited from the mother's line, adorn the button blankets which are the traditional ceremonial robes that serve to identify the family of the wearer. Written instructions and diagrams guide students in…
"Intelligent Design" Goes on Trial in Pennsylvania
ERIC Educational Resources Information Center
Cavanagh, Sean
2005-01-01
The question of whether "intelligent design" amounts to legitimate science, pseudo-science, or religion masquerading as science has underwent a potentially historic legal test, as a federal court in Pennsylvania considered whether a public school district can require that students be exposed to the controversial concept. Eleven parents…
Adolescent Satanism: Rebellion Masquerading as Religion.
ERIC Educational Resources Information Center
Emerson, Shirley; Syron, Yvonne
1995-01-01
Describes adolescent satanic practices of affected families in three Southwestern states in a seven-year period. Counselors need to understand how satanism is related to religion, family dynamics, and adolescent rebellion. A systemic perspective is suggested. Counselors must be aware of their own biases to be able to help satanically involved…
Manufacturing (Il)Literacy in Alberta's Classrooms: The Case of an Oil-Dependent State
ERIC Educational Resources Information Center
Hodgkins, Andrew
2010-01-01
This paper examines involvement of education-business "partnerships" presently occurring in the province of Alberta, Canada. Specific attention is paid to the promotion and sponsorship by oil multinational corporations (MNCs) of corporate propaganda masquerading as energy and environmental literacy programs targeted for the K-12 school…
Cerebellopontine angle epidermoid tumour presenting with bilateral gaze nystagmus.
Han, I B; Huh, R; Chung, S S; Kim, O J
2008-06-01
Vestibular symptoms have been rarely described in cerebellopontine angle epidermoid tumours. We report a case of CPA epidermoid tumour presenting with subacute onset of vestibular symptoms such as vertigo, gait ataxia, and nystagmus masquerading as acute vestibular neuritis or central vertigo. The vestibular symptoms disappeared after excision of the tumour.
ERIC Educational Resources Information Center
Armstrong, Charley
2005-01-01
In this article, the author describes The Button Project. It started as a dream, a need to educate future generations about the Holocaust, to teach tolerance, and to remember the past. Under the auspices of the Jewish Federation of Peoria, a small band of people joined together with the goal of teaching people about the Holocaust so that it will…
USDA-ARS?s Scientific Manuscript database
Food preparation skills may encourage healthy eating. Traditional assessment of child food preparation employs self- or parent proxy-reporting methods, which are prone to error. The eButton is a wearable all-day camera that has promise as an objective, passive method for measuring child food prepara...
31. VIEW OF A WORKER HOLDING A PLUTONIUM 'BUTTON.' PLUTONIUM, ...
31. VIEW OF A WORKER HOLDING A PLUTONIUM 'BUTTON.' PLUTONIUM, A MAN-MADE SUBSTANCE, WAS RARE. SCRAPS RESULTING FROM PRODUCTION AND PLUTONIUM RECOVERED FROM RETIRED NUCLEAR WEAPONS WERE REPROCESSED INTO VALUABLE PURE-PLUTONIUM METAL (9/19/73). - Rocky Flats Plant, Bounded by Indiana Street & Routes 93, 128 & 72, Golden, Jefferson County, CO
"Urgency tip": a portable patient-activated device for objective measurement of urinary urgency.
Kobayashi, Hideki; Araki, Isao; Tsuchida, Takayuki; Zakoji, Hidenori; Mikami, Yuki; Takeda, Masayuki; Kiyohiro, Noriaki
2007-03-01
For clinical practice and research of overactive bladder syndrome, it is essential to evaluate urgency symptoms in daily life. We have developed a portable patient-activated device to record bladder sensations. This electronic device is pocket-size and light, with five grading buttons and another button for cancellation.
46 CFR 121.510 - Recommended emergency broadcast instructions.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Immediate Danger to Life or Property. (4) Say: “THIS IS (INSERT VESSEL'S NAME), (INSERT VESSEL'S NAME), (INSERT VESSEL'S NAME), (INSERT VESSEL'S CALL SIGN), OVER.” (5) Release the microphone button briefly and... 16 VHF and 2182 kHz on SSB are for emergency and calling purposes only.) (3) Press microphone button...
Lim, L T; Bhatt, P R; Ramaesh, K
2008-11-01
To describe an alternative and novel technique using cyanoacrylate glue to achieve successful limbal tissue dissection, from an organ culture media stored corneoscleral button, without an artificial anterior chamber. A donor corneoscleral button (leftover from penetrating keratoplasty) was divided into two equal semicircular halves. A thick layer of tissue adhesive (N-butyl-2-cyanoacrylate) was spread on a sterile rubber block (the under surface of the donor punch). One half of the donor corneoscleral rim was placed epithelial side up on the adhesive and allowed to attach firmly to the block. This composite provided stability to the donor rim allowing lamellar dissection of the limbal tissue to be performed without damaging the limbal epithelium. Regular, partial-thickness limbal tissue was obtained. There was no histological evidence of glue or cellular toxicity of the harvested limbal stem cells. This harvested tissue had been grafted successfully in patients with limbal stem cell deficiency also undergoing keratoplasty. Tissue adhesive can be a simple, effective and useful tool in the dissection and harvesting of corneal limbal stem cell allografts from corneoscleral buttons stored in organ culture media.
Alikhani-Koupaei, Majid; Mazlumzadeh, Meisam; Sharifani, Mohamadmehdi; Adibian, Mohamad
2014-01-01
Fresh button mushrooms (Agaricus bisporus L.) are sensitive to browning, water loss, and microbial attack. The short shelf-life of mushrooms is an impediment to the distribution and marketing of the fresh product. Essential oils outstand as an alternative to chemical preservatives and their use in foods meets the demands of consumers for natural products. To resolve controlled release of oil and increase in antioxidant and antimicrobial activities, the oil was incorporated into microcapsules. Effects of microcapsulated thyme (Thymus vulgaris L.) and rosemary (Rosmarinus officinalis L.) on quality of fresh button mushroom were compared. Physicochemical qualities were evaluated during 15 days of storage at 4 ± 0.5°C. All treatments prevented product weight loss and decrease in polyphenoloxidase and peroxidase activities during storage. Color and firmness, microbiological analysis, and total phenolic content caused the least change. With use of microencapsulated oils, mushrooms were within acceptable limits during 10 days of storage. Microencapsulated rosemary oil produced the highest beneficial effects and has potential to improve quality of button mushrooms and extend shelf-life. PMID:25473510
Household chemicals: management of intoxication and antidotes.
Rauber-Lüthy, Christine; Kupferschmidt, Hugo
2010-01-01
Exposure to household products is very common, but in industrialized countries severe or fatal poisoning with household products is rare today, due to the legal restriction of sale of hazardous household products. The big challenge for physicians, pharmacologists and toxicologists is to identify the few exceptional life-threatening situations where immediate intervention is needed. Among thousands of innocuous products available for the household only very few are hazardous. Substances found in these products include detergents, corrosives, alcohols, hydrocarbons, and some of the essential oils. The ingestion of batteries and magnets and the exposure to cyanoacrylates (super glue) can cause complications in exceptional situations. Among the most dangerous substances still present in household products are ethylene glycol and methanol. These substances cause major toxicity only through their metabolites. Therefore, initial symptoms may be only mild or absent. Treatment even in asymptomatic patients has to be initiated as early as possible to inhibit production of toxic metabolites. For all substances not only the compound itself but also the route of exposure is relevant for toxicity. Oral ingestion and inhalation generally lead to most pronounced symptoms, while dermal exposure is often limited to mild irritation. However, certain circumstances need special attention. Exposure to hydrofluoric acid may lead to fatal hypocalcemia, depending on the concentration, duration of exposure, and area of the affected skin. Accidents with hydrocarbon pressure injectors and spray guns are very serious events, which may lead to amputation of affected limbs. Button batteries normally pass the gastrointestinal tract without problems even in toddlers; in rare cases, however, they get lodged in the esophagus with the risk of localized tissue damage and esophageal perforation.
Aniridia-related keratopathy: Structural changes in naïve and transplanted corneal buttons
Stenevi, Ulf; Pedrosa Domellöf, Fátima
2018-01-01
Background To study structural changes in naïve and surgically treated corneas of aniridia patients with advanced aniridia-related keratopathy (ARK). Methods and findings Two naïve corneal buttons from patients with advanced ARK submitted to penetrating keratoplasty for the first time, one corneal button from an ARK patient that had undergone a keratolimbal allograft (KLAL), two corneal buttons from ARK patients who had previously undergone centered or decentered transplantation and were now retransplanted and two adult healthy donor control corneas were processed for immunohistochemistry. Antibodies against extracellular matrix components in the stroma and in the epithelial basement membrane (collagen I and IV, collagen receptor α11 integrin and laminin α3 chain), markers of fibrosis, wound healing and vascularization (fibronectin, tenascin-C, vimentin, α-SMA and caveolin-1), cell division (Ki-67) and macrophages (CD68) were used. Naïve ARK, KLAL ARK corneas and transplanted corneal buttons presented similar histopathological changes with irregular epithelium and disruption or absence of epithelial basal membrane. There was a loss of the orderly pattern of collagen lamellae and absence of collagen I in all ARK corneas. Vascularization was revealed by the presence of caveolin-1 and collagen IV in the pannus of all ARK aniridia corneas. The changes observed in decentered and centered transplants were analogous. Conclusions Given the similar pathological features of all cases, conditions inherent to the host seem to play an important role on the pathophysiology of the ARK in the long run. PMID:29889891
Aniridia-related keratopathy: Structural changes in naïve and transplanted corneal buttons.
Vicente, André; Byström, Berit; Lindström, Mona; Stenevi, Ulf; Pedrosa Domellöf, Fátima
2018-01-01
To study structural changes in naïve and surgically treated corneas of aniridia patients with advanced aniridia-related keratopathy (ARK). Two naïve corneal buttons from patients with advanced ARK submitted to penetrating keratoplasty for the first time, one corneal button from an ARK patient that had undergone a keratolimbal allograft (KLAL), two corneal buttons from ARK patients who had previously undergone centered or decentered transplantation and were now retransplanted and two adult healthy donor control corneas were processed for immunohistochemistry. Antibodies against extracellular matrix components in the stroma and in the epithelial basement membrane (collagen I and IV, collagen receptor α11 integrin and laminin α3 chain), markers of fibrosis, wound healing and vascularization (fibronectin, tenascin-C, vimentin, α-SMA and caveolin-1), cell division (Ki-67) and macrophages (CD68) were used. Naïve ARK, KLAL ARK corneas and transplanted corneal buttons presented similar histopathological changes with irregular epithelium and disruption or absence of epithelial basal membrane. There was a loss of the orderly pattern of collagen lamellae and absence of collagen I in all ARK corneas. Vascularization was revealed by the presence of caveolin-1 and collagen IV in the pannus of all ARK aniridia corneas. The changes observed in decentered and centered transplants were analogous. Given the similar pathological features of all cases, conditions inherent to the host seem to play an important role on the pathophysiology of the ARK in the long run.
Raber, Margaret; Patterson, Monika; Jia, Wenyan; Sun, Mingui; Baranowski, Tom
2018-02-24
Food preparation skills may encourage healthy eating. Traditional assessment of child food preparation employs self- or parent proxy-reporting methods, which are prone to error. The eButton is a wearable all-day camera that has promise as an objective, passive method for measuring child food preparation practices. This paper explores the feasibility of the eButton to reliably capture home food preparation behaviors and practices in a sample of pre- and early adolescents (ages 9 to 13). This is a secondary analysis of two eButton pilot projects evaluating the dietary intake of pre- and early adolescents in or around Houston, Texas. Food preparation behaviors were coded into seven major categories including: browsing, altering food/adding seasoning, food media, meal related tasks, prep work, cooking and observing. Inter-coder reliability was measured using Cohen's kappa and percent agreement. Analysis was completed on data for 31 participants. The most common activity was browsing in the pantry or fridge. Few participants demonstrated any food preparation work beyond unwrapping of food packages and combining two or more ingredients; actual cutting or measuring of foods were rare. Although previous research suggests children who "help" prepare meals may obtain some dietary benefit, accurate assessment tools of food preparation behavior are lacking. The eButton offers a feasible approach to food preparation behavior measurement among pre- and early adolescents. Follow up research exploring the validity of this method in a larger sample, and comparisons between cooking behavior and dietary intake are needed.
Is Radiologic Evaluation Necessary to Find out Foreign Bodies in Nasal Cavity?
Oh, Hoon; Min, Hyun Jin; Yang, Hoon Shik; Kim, Kyung Soo
2016-01-01
Although there were previous studies on the clinical aspects such as etiology, treatment modalities, studies regarding the necessity of radiologic evaluation for nasal foreign body were limited. The aim of this study is to evaluate the necessity and indication of radiologic evaluation for nasal foreign bodies. There are consecutive patients aged less than 10 years who presented with suspected foreign bodies in nasal cavity. We reviewed the patient's age and sex, including the methods of evaluation, management tools, and types of foreign bodies. There were 35 cases (11.4%) on whom radiographs were performed in the 24 uncooperative patients and 11 cooperative patients who were not identified with any foreign bodies via nasal endoscopy. Among them, only 4 cases had positive reports of foreign body and the others were normal radiologic findings. We suggest that the radiologic evaluation is always not necessary to find the location of nasal foreign bodies. It, however, should be performed in cases of negative findings of physical examination with anterior rhinoscopy or sinus endoscopy and unwitnessed foreign bodies to rule out metallic contents, especially button type battery.
Magalhães-Costa, Pedro; Carvalho, Liliana; Rodrigues, José Pedro; Túlio, Maria Ana; Marques, Susana; Carmo, Joana; Bispo, Miguel; Chagas, Cristina
2016-01-01
Gastrointestinal foreign bodies (FB) are comprised of food bolus impaction and intentionally or unintentionally ingested or inserted true FB. Food bolus impaction and true FB ingestion represent a recurrent problem and a true challenge in gastrointestinal endoscopy. More than 80-90% of the ingested true FB will pass spontaneously through the gastrointestinal tract without complications. However, in 10-20% of the cases an endoscopic intervention is deemed necessary. True FB ingestion has its greatest incidence in children, psychiatric patients and prisoners. On the other hand, food bolus impaction typically occurs in the elderly population with an underlying esophageal pathology. The most serious situations, with higher rates of complications, are associated with prolonged esophageal impaction, ingestion of sharp and long objects, button batteries and magnets. Physicians should recognize early alarm symptoms, such as complete dysphagia, distressed patients not able to manage secretions, or clinical signs of perforation. Although many papers are yearly published regarding this subject, our knowledge is mainly based on case-reports and retrospective series. Herein, the authors summarize the existing evidence and propose an algorithm for the best approach to FB ingestion.
Development of CMOS Imager Block for Capsule Endoscope
NASA Astrophysics Data System (ADS)
Shafie, S.; Fodzi, F. A. M.; Tung, L. Q.; Lioe, D. X.; Halin, I. A.; Hasan, W. Z. W.; Jaafar, H.
2014-04-01
This paper presents the development of imager block to be associated in a capsule endoscopy system. Since the capsule endoscope is used to diagnose gastrointestinal diseases, the imager block must be in small size which is comfortable for the patients to swallow. In this project, a small size 1.5V button battery is used as the power supply while the voltage supply requirements for other components such as microcontroller and CMOS image sensor are higher. Therefore, a voltage booster circuit is proposed to boost up the voltage supply from 1.5V to 3.3V. A low power microcontroller is used to generate control pulses for the CMOS image sensor and to convert the 8-bits parallel data output to serial data to be transmitted to the display panel. The results show that the voltage booster circuit was able to boost the voltage supply from 1.5V to 3.3V. The microcontroller precisely controls the CMOS image sensor to produce parallel data which is then serialized again by the microcontroller. The serial data is then successfully translated to 2fps image and displayed on computer.
Modifications in endoscopic practice for pediatric patients.
Lightdale, Jenifer R; Acosta, Ruben; Shergill, Amandeep K; Chandrasekhara, Vinay; Chathadi, Krishnavel; Early, Dayna; Evans, John A; Fanelli, Robert D; Fisher, Deborah A; Fonkalsrud, Lisa; Hwang, Joo Ha; Kashab, Mouen; Muthusamy, V Raman; Pasha, Shabana; Saltzman, John R; Cash, Brooks D
2014-05-01
We recommend that endoscopy in children be performed by pediatric-trained endoscopists whenever possible. We recommend that adult-trained endoscopists coordinate their services with pediatricians and pediatric specialists when they are needed to perform endoscopic procedures in children. We recommend that endoscopy be performed within 24 hours in symptomatic pediatric patients with known or suspected ingestion of caustic substances. We recommend emergent foreign-body removal of esophageal button batteries, as well as 2 or more rare-earth neodymium magnets. We recommend that procedural and resuscitative equipment appropriate for pediatric use should be readily available during endoscopic procedures. We recommend that personnel trained specifically in pediatric life support and airway management be readily available during sedated procedures in children. We recommend the use of endoscopes smaller than 6 mm in diameter in infants and children weighing less than 10 kg. We recommend the use of standard adult duodenoscopes for performing ERCP in children who weigh at least 10 kg. We recommend the placement of 12F or 16F percutaneous endoscopic gastrostomy tubes in children who weigh less than 50 kg.
Fixation of the Achilles tendon insertion using suture button technology.
Fanter, Nathan J; Davis, Edward W; Baker, Champ L
2012-09-01
In the operative treatment of Achilles insertional tendinopathy, no guidelines exist concerning which form of fixation of the Achilles tendon insertion is superior. Transcalcaneal drill pin passage does not place any major plantar structures at risk, and the addition of a Krackow stitch and suture button to the fixation technique provides a significant increase in ultimate load to failure in Achilles tendon insertional repairs. Controlled laboratory study. The Achilles tendon insertions in 6 fresh-frozen cadaveric ankles were detached, and transcalcaneal drill pins were passed. Plantar dissection took place to evaluate the drill pin relationship to the plantar fascia, lateral plantar nerve and artery, flexor digitorum longus tendon, and master knot of Henry. The Achilles tendons were then repaired with a double-row suture anchor construct alone or with a suture button and Krackow stitch added to the double-row suture anchor construct. The repairs were then tested to maximum load to failure at 20 mm/min. The mode of failure was recorded, and the mean maximum load to failure was assessed using the Student t test for distributions with equal variance. Transcalcaneal drill pin passage did not place any selected anatomic structures at risk. The mean maximum load to failure for the suture bridge group was 239.2 N; it was 391.4 N for the group with the suture button (P = .014). The lateral plantar artery was the structure placed at greatest risk from drill pin placement, with a mean distance of 22.7 mm (range, 16.5-29.2 mm) between the pin and artery. In this laboratory study, transcalcaneal drill pin passage appeared to be anatomically safe, and the use of suture button technology with a Krackow stitch for Achilles tendon insertional repair significantly increased repair strength. Achilles tendon insertional repair with suture button fixation and a Krackow stitch may facilitate the earlier institution of postoperative rehabilitation and improve clinical outcomes.
Napoleon's Buttons: Teaching the Role of Chemistry in History
ERIC Educational Resources Information Center
Samet, Cindy; Higgins, Pamela J.
2005-01-01
A course designed on the theme of Napoleon's Buttons, which states that there is a connection between the chemical structure of a compound and its pivotal moments in history affecting the development of society is explained. Students liked the book choice for the course because the focus was not on straight chemistry, but the intersection of…
Designing a Machinery Control System (MCS) Security Testbed
2014-09-01
IO LAB” button and verify the display looks as follows: 95 Figure F22 . “Ready State” (and start state)of the DIOL as displayed at the HMI...After verification that the HMI screen looks like Figure F22 , click on the “Back to Home Screen” button and return to the HMI “Home” screen as seen
78 FR 66099 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-04
... every year (a) by an ophthalmologist or optometrist who attests that the vision in the better eye... showing that the vision in the better eye continues to meet the requirement specified at 49 CFR 391.41(b... click the search button. When the new screen appears, click on the blue ``Comment Now!'' button on the...
Peach fruit set and buttoning after spring frost
USDA-ARS?s Scientific Manuscript database
A spring frost occurred on 29 Mar. 2015 at the USDA-ARS Byron station after three weeks of blooming when most fruitlets were forming. Due to severe fruitlet drop, the overall fruit set on a scale of 0-9 was substantially reduced, from 5.61 averaged in 2014 to 2.61 in 2015. In addition, buttons (abno...
Mechanical Design of Metal Dome for Industrial Application
NASA Astrophysics Data System (ADS)
Jin-Chee Liu, Thomas; Chen, Li-Wei; Lin, Nai-Pin
2018-02-01
In this paper, the mechanical design of metal domes is studied using finite element analysis. The snap-through behavior of a practical button design that uses a metal dome is found. In addition, the individual click ratio and maximum force for a variety of metal domes are determined. This paper provides guidance on button design for industrial engineers.
Mullinax, Jerry L.
1988-01-01
A tube support for supporting horizontal tubes from an inclined vertical support tube passing between the horizontal tubes. A support button is welded to the vertical support tube. Two clamping bars or plates, the lower edges of one bearing on the support button, are removably bolted to the inclined vertical tube. The clamping bars provide upper and lower surface support for the horizontal tubes.
NASA Astrophysics Data System (ADS)
Cowan, James J.
1984-05-01
A unique type of holographic imagery and its large scale replication are described. The "Newport Button", which was designed as an advertising premium item for the Newport Corporation, incorporates a complex overlay of holographic diffraction gratings surrounding a three-dimensional holographic image of a real object. The combined pattern is recorded onto a photosensitive medium from which a metal master is made. The master is subsequently used to repeatedly emboss the pattern into a thin plastic sheet. Individual patterns are then die cut from the metallized plastic and mounted onto buttons. A discussion is given of the diffraction efficiencies of holograms made in this particular fashion and of the special requirements of the replication process.
Benign Granuloma Masquerading as Squamous Cell Carcinoma Due to a “Floater”
Prat, Madeleine P; Hostler, David C
2017-01-01
Pathology specimen cross-contamination is a rare phenomenon in diagnostic pathology. Such “floaters” may result in delayed, missed or erroneous diagnoses. We describe the case of a patient with benign granuloma of the lung initially misdiagnosed as squamous cell carcinoma due to a “floater.” PMID:29164012
Early Motor Unit Disease Masquerading as Psychogenic Breathy Dysphonia: A Clinical Case Presentation
ERIC Educational Resources Information Center
Aronson, Arnold E.
1971-01-01
Presented is a study of a 20-year-old girl with mild, breathy dysphonia, previously diagnosed as psychogenic. In actuality, her voice change was a sign of early myasthenia gravis. It is pointed out that voice changes can be a first and only sign of early neurologic disease. (Author/KW)
Little Masquerade: Russia’s Evolving Employment Of Maskirovka
2016-05-26
formations and equipment. Camouflage and radar scattering nets, awnings, screens, and smoke are additional means to prevent observation and detection.30...light discipline, engagement restrictions ( fire discipline), and communication restrictions.31...same inert techniques but augments them with real equipment, soldiers, smoke , sounds, and light signatures.33 Creation of a false assembly area with
Sellar and supra-sellar glioblastoma masquerading as a pituitary macroadenoma.
Mahta, Ali; Buhl, Ralf; Huang, Hongguang; Jansen, Olav; Kesari, Santosh; Ulmer, Stephan
2013-04-01
A few number of suprasellar gliomas have been reported thus far of which, some of them developed several years after radiation therapy for pituitary adenomas or craniopharyngiomas. Herein, we report a case of sellar glioblastoma with suprasellar extension with no prior radiation history who mimicked clinical and radiologic findings of a pituitary macroadenoma.
Plotting Inequalities, Building Resistance
ERIC Educational Resources Information Center
Renner, Adam; Brew, Bridget; Proctor, Crystal
2012-01-01
Media depictions of San Francisco show idyllic images of fog pouring under the Golden Gate Bridge or happy tourists riding cable cars, but rarely the mostly nonwhite neighborhoods of the east side. San Francisco public schools have a bad track record of mimicking this masquerade, with very low numbers of African American and Latina/o students…
Ectopic canine associated with a dentigerous cyst in the maxilla.
Thakur, Jagdeep S; Mohindroo, Narinder K; Sharma, Dev R; Minhas, Ravinder S; Thakur, Anamika
2011-06-01
Ectopic eruption of a tooth is common in the dental arch, palate, and nose, but it is rare in the maxillary antrum. We present the case of a 35-year-old man with an ectopic canine and an associated dentigerous cyst in the maxillary sinus that masqueraded as an antrochoanal polyp.
Neoliberalism, Social Darwinism, and Consumerism Masquerading as School Reform
ERIC Educational Resources Information Center
Tienken, Christopher H.
2013-01-01
Education reform policies harvested from neoliberalism, social Darwinism, consumerism, and free-market ideologies have begun to replace the pragmatic progressivism of the pre-World War II era. In this article, I use three federal and state education reform policies and programs--No Child Left Behind Act, Common Core State Standards Initiative, and…
High-dose calcium stimulation test in a case of insulinoma masquerading as hysteria.
Nakamura, Yoshio; Doi, Ryuichiro; Kohno, Yasuhiro; Shimono, Dai; Kuwamura, Naomitsu; Inoue, Koichi; Koshiyama, Hiroyuki; Imamura, Masayuki
2002-11-01
It is reported that some cases with insulinoma present with neuropsychiatric symptoms and are often misdiagnosed as psychosis. Here we report a case of insulinoma masquerading as hysteria, whose final diagnosis could be made using high-dose calcium stimulation test. A 28-yr-old woman was referred presenting with substupor, mutism, mannerism, restlessness, and incoherence. Laboratory examinations revealed hypoglycemia (33 mg/dL) and detectable insulin levels (9.7 microU/mL), suggesting the diagnosis of insulinoma. However, neither imaging studies nor selective arterial calcium injection (SACI) test with a conventional dose of calcium (0.025 mEq/kg) indicated the tumor. High-dose calcium injection (0.05 mEq/kg) evoked insulin secretion when injected into superior mesenteric artery. A solitary tumor in the head of the pancreas was resected, and her plasma glucose returned to normal. Postoperatively, iv injection of secretin resulted in a normal response of insulin, which was not found preoperatively. This case suggests the usefulness of the SACI test with high-dose of calcium in the case of insulinoma when the standard dose fails to detect such a tumor.
Cross-reactivity and masqueraders in seafood reactions.
Banks, Taylor A; Gada, Satyen M
2013-01-01
Confounding variables play a significant role in many adverse seafood reactions and a clear understanding of these factors is important in properly characterizing reactions associated with potential masqueraders and mimics. Although the medical literature is replete with reviews of seafood hypersensitivity and reports of cross-reactive and newly characterized allergens, there has not been a recent effort to provide an updated overview of the several processes that may lead clinicians to draw incorrect conclusions in evaluating reported reactions to seafood. Ranging from seafood intoxications to other nonallergic or complex seafood reactions, these events can easily be misconstrued as representing a seafood IgE-mediated allergy. Among these are the more familiar topics of cross-reactivity and scombroid intoxication, and those with a still evolving understanding such as ciguatera fish poisoning and Anisakis reactions. This article seeks to provide an accessible but comprehensive summary of the relevant information surrounding these confounders in assessing adverse reactions to seafood. Such knowledge may be instrumental in unraveling complex or otherwise unclear presentations and aid clinicians in accurately evaluating and managing patients with reported seafood reactions.
Giant ovarian cyst masquerading as a massive ascites: a case report.
Yeika, Eugene Vernyuy; Efie, Derrick Tembi; Tolefac, Paul Nkemtendong; Fomengia, Joseph Nkeangu
2017-12-19
Giant ovarian cysts are tumours of the ovary presenting with diameters greater than 10 cm. Giant ovarian cysts have become rare in recent days as they are diagnosed and managed early due to the availability of good imaging modalities. The aim of this case report is to show how a huge cystic ovarian mass can mislead the diagnosis of ascites in a postmenopausal woman. Factors associated with late presentation of giant ovarian cysts in sub-Saharan Africa have also been discussed. We present the case of a 65-year-old grand multiparous woman who was referred to our centre with a grossly distended abdomen misdiagnosed as a massive ascites. Abdominopelvic ultrasound scan revealed a right giant multiloculated ovarian cyst. She benefited from a cystectomy with an uneventful postoperative stay. Histopathology revealed mucinous cystadenoma. Large cystic ovarian tumours can present masquerading as massive ascites and misleading diagnosis as in this case report. We report this case to increase the suspicion index of a large ovarian cyst in all women presenting with massive ascites.
A Case of Retained Graphite Anterior Chamber Foreign Body Masquerading as Stromal Keratitis
Han, Eun Ryung; Wee, Won Ryang; Lee, Jin Hak
2011-01-01
We report a case of a retained graphite anterior chamber foreign body that was masquerading as stromal keratitis. A 28-year-old male visited with complaints of visual disturbance and hyperemia in his right eye for four weeks. On initial examination, he presented with a stromal edema involving the inferior half of the cornea, epithelial microcysts, and moderate chamber inflammation. Suspecting herpetic stromal keratitis, he was treated with anti-viral and anti-inflammatory agents. One month after the initial visit, anterior chamber inflammation was improved and his visual acuity recovered to 20/20, but subtle corneal edema still remained. On tapering the medication, after three months, a foreign body was incidentally identified in the inferior chamber angle and was surgically removed resulting in complete resolution of corneal edema. The removed foreign body was a fragment of graphite and he subsequently disclosed a trauma with mechanical pencil 12 years earlier. This case showed that the presence of an anterior chamber foreign body should always be considered in the differential diagnosis of idiopathic localized corneal edema. PMID:21461226
How preschoolers and adults represent their joint action partner's behavior.
Sacheli, Lucia Maria; Meyer, M; Hartstra, E; Bekkering, H; Hunnius, S
2017-10-24
We investigated the cognitive mechanisms underlying turn-taking joint action in 42-month-old children (Experiment 1) and adults (Experiment 2) using a behavioral task of dressing a virtual bear together. We aimed to investigate how participants represent a partners' behavior, i.e., in terms of specific action kinematics or of action effects. The bear was dressed by pressing a smaller and a bigger button. In the Action-response task, instructions asked participants to respond to the partner by pressing the same or opposite button; in the Action-effect task they had to respond to the partner's action effect by dressing the bear with the lacking part of the clothing, which in some cases implied pressing the same button and in other cases implied pressing the opposite button. In 50% of the trials, the partner's association between each button and the ensuing effect (dressing the bear with t-shirt or pants) was reversed, while it never changed for participants. Both children and adults showed no effect of physical congruency of actions, but showed impaired performance in the Action-effect task if their partner achieved her effect through a different action-effect association than their own. These results suggest that, when encoding their partner's actions, agents are influenced by action-effect associations that they learnt through their own experience. While interference led to overt errors in children, it caused longer reaction times in adults, suggesting that a flexible cognitive control (that is still in development in young children) is required to take on the partner's perspective.
Automatic food detection in egocentric images using artificial intelligence technology.
Jia, Wenyan; Li, Yuecheng; Qu, Ruowei; Baranowski, Thomas; Burke, Lora E; Zhang, Hong; Bai, Yicheng; Mancino, Juliet M; Xu, Guizhi; Mao, Zhi-Hong; Sun, Mingui
2018-03-26
To develop an artificial intelligence (AI)-based algorithm which can automatically detect food items from images acquired by an egocentric wearable camera for dietary assessment. To study human diet and lifestyle, large sets of egocentric images were acquired using a wearable device, called eButton, from free-living individuals. Three thousand nine hundred images containing real-world activities, which formed eButton data set 1, were manually selected from thirty subjects. eButton data set 2 contained 29 515 images acquired from a research participant in a week-long unrestricted recording. They included both food- and non-food-related real-life activities, such as dining at both home and restaurants, cooking, shopping, gardening, housekeeping chores, taking classes, gym exercise, etc. All images in these data sets were classified as food/non-food images based on their tags generated by a convolutional neural network. A cross data-set test was conducted on eButton data set 1. The overall accuracy of food detection was 91·5 and 86·4 %, respectively, when one-half of data set 1 was used for training and the other half for testing. For eButton data set 2, 74·0 % sensitivity and 87·0 % specificity were obtained if both 'food' and 'drink' were considered as food images. Alternatively, if only 'food' items were considered, the sensitivity and specificity reached 85·0 and 85·8 %, respectively. The AI technology can automatically detect foods from low-quality, wearable camera-acquired real-world egocentric images with reasonable accuracy, reducing both the burden of data processing and privacy concerns.
Charlton, Timothy; Boe, Chelsea; Thordarson, David B
2015-12-01
Chronic Lisfranc injury is a subtle and severe injury in high-level athletes, including dancers. This patient population is generally intolerant of intra-articular screw fixation and can develop significant post-traumatic arthritis with potentially career ending complications. Flexible fixation with suture-button devices provides potential restoration of physiologic motion at the joint, with appropriate support for healing that may facilitate return to en pointe activities for dancers. We hypothesized that the suture-button device would restore motion at the Lisfranc joint and allow for return to activities in this particular population without the limitations and complications of rigid fixation. We operated on seven dancers and high-level athletes with diagnosed Lisfranc injuries by installing a suture-button device. All patients had failed conservative management after late presentation. They were allowed to return to sport in 6 months, preoperative and postoperative American Orthopaedic Foot and Ankle Score (AOFAS) foot scores were obtained, and patients were followed for a minimum of 15 months. All seven returned to full activities in 6 months, with radiographic evidence of fixation and no complications to date. AOFAS foot scores improved from an average of 65 preoperatively to an average of 97 postoperatively at latest follow-up. It is concluded that flexible fixation with suture-button type device represents a viable alternative to screw fixation or fusion that may allow dancers and athletes to return to previous levels of activity after Lisfranc injury. This case series represents to our knowledge the first application of this device to a unique population that requires flexibility at the Lisfranc joint for performance.
ERIC Educational Resources Information Center
Bucholtz, Kevin M.
2011-01-01
For some students, organic chemistry can be a distant subject and unrelated to any courses they have seen in their college careers. To develop a more contextual learning experience in organic chemistry, an additional text, "Napoleon's Buttons: 17 Molecules That Changed History," by Penny Le Couteur and Jay Burreson, was incorporated as a…
Miniature Two-Axis Joystick Controller
NASA Technical Reports Server (NTRS)
Hollow, R.
1983-01-01
Novel movable-button-actuated self-centering controller uses optoelectronics to produce X and Y signals for aircraft control. In addition to be extremely compact, device puts our voltages having high signal-to-noise ratio, especially at critical center position where in many controllers this ratio is poorest. Combination of new saddle-shaped button and positive centering gives "feel" and "breakout" met with pilot approval.
:#ccc;text-align:center;padding:5px}.upper_button{text-align:right;padding-bottom:5px}.side_button[type ;width:175px;text-align:left;font-weight:bold;overflow:hidden}.left_head_title_alt{float:left;width:175px ;text-align:left;font-weight:bold;line-height:16px;margin-top:3px;padding-top:0}.left_head_add
Emmanuelle Morin; Annegret Kohler; Adam R. Baker; Marie Foulongne-Oriol; Vincent Lombard; Laszlo G. Nagy; Robin A. Ohm; Aleksandrina Patyshakuliyeva; Annick Brun; Andrea L. Aerts; Andrew M. Bailey; Christophe Billette; Pedro M. Coutinho; Greg Deakin; Harshavardhan Doddapaneni; Dimitrios Floudas; Jane Grimwood; Kristiina Hild& #233; n; Ursula K& #252; es; Kurt M. LaButti; Alla Lapidus; Erika A. Lindquist; Susan M. Lucas; Claude Murat; Robert W. Riley; Asaf A. Salamov; Jeremy Schmutz; Venkataramanan Subrananian; Han A.B. W& #246; sten; Jianping Xu; Daniel C. Eastwood; Gary D. Foster; Anton S.M. Sonnenberg; Daniel Cullen; Ronald P. de Vries; Taina Lundell; David S. Hibbett; Bernard Henrissat; Kerry S. Burton; Richard W. Kerrigan; Michael P. Challen; Igor V. Grigoriev; Francis Martin
2012-01-01
Agaricus bisporus is the model fungus for the adaptation, persistence,and growth in the humic-rich leaf-litter environment. Aside from its ecological role, A. bisporus has been an important component of the human diet for over 200 y and worldwide cultivation of the "button mushroom" forms a multibillion dollar...
NASA Astrophysics Data System (ADS)
Jue, Brian J.; Bice, Michael D.
2013-07-01
As students explore the technological tools available to them for learning mathematics, some will eventually discover what happens when a function button is repeatedly pressed on a calculator. We explore several examples of this, presenting tabular and graphical results for the square root, natural logarithm and sine and cosine functions. Observed behaviour is proven and then discussed in the context of fixed points.
A burr hole button to secure the electrode cable in depth electrode placement. Technical note.
Kamiryo, T; Laws, E R
1997-05-01
A simple magnetic resonance imaging-compatible buttonlike device was devised to fix a depth electrode cable securely in the burr hole used for its insertion during surgery for depth electrode placement. The button is tightly fixed in the burr hole and it holds the cable without allowing protrusion or tension on the wound.
ERIC Educational Resources Information Center
Dority Baker, Marcia L.
2013-01-01
This article provides a case study of how the University of Nebraska College of Law and Schmid Law Library use "buttons" to manage Law College faculty members' and librarians' online presence. Since Google is the primary search engine used to find information, it is important that librarians and libraries assist Web site visitors in…
fixme{background-color:#ff0}.container-fluid{padding:0;margin:0}.hp{font-family:Roboto," }.hp-hero-text{position:absolute;text-shadow:1px 1px 1px rgba(150,150,150,1)}.hp-hero h2{color:#fff}.hp -hero button{color:#e3e3e3;font-size:10px;background:transparent;border:none}.hp-hero button:hover,.hp
Henz, Sonja; Kutz, Dieter F.; Werner, Jana; Hürster, Walter; Kolb, Florian P.; Nida-Ruemelin, Julian
2015-01-01
The aim of the study was to determine whether a deliberative process, leading to a motor action, is detectable in high density EEG recordings. Subjects were required to press one of two buttons. In a simple motor task the subject knew which button to press, whilst in a color-word Stroop task subjects had to press the right button with the right index finger when meaning and color coincided, or the left button with the left index finger when meaning and color were disparate. EEG recordings obtained during the simple motor task showed a sequence of positive (P) and negative (N) cortical potentials (P1-N1-P2) which are assumed to be related to the processing of the movement. The sequence of cortical potentials was similar in EEG recordings of subjects having to deliberate over how to respond, but the above sequence (P1-N1-P2) was preceded by slowly increasing negativity (N0), with N0 being assumed to represent the end of the deliberation process. Our data suggest the existence of neurophysiological correlates of deliberative processes. PMID:26190987
Prabhu, Jagadish; Faqi, Mohammed Khalid; Alkhalifa, Fahad; Tayara, Bader Kamal; Awad, Rashad Khamis
2017-01-01
Injuries to the pectoralis major muscle are relatively infrequent. The mechanism of injury is usually an eccentric shortening of the pectoralis major under heavy load, such as when performing a bench press exercise. We report a case that presented to us with a history of sudden pain in the left pectoral region while doing heavy bench press exercise. The patient sustained a type III D pectoralis muscle -tendon avulsion. Surgical repair was done through a bi-cortical tendon sliding technique using two cortical buttons. In this article we describe our modifications to the previously described surgical technique for the pectoralis major tendon repair using the EndoButton and tension - slide technique, aiming to overcome the possible complications.
Fixation of unstable type II clavicle fractures with distal clavicle plate and suture button.
Johnston, Peter S; Sears, Benjamin W; Lazarus, Mark R; Frieman, Barbara G
2014-11-01
This article reports on a technique to treat unstable type II distal clavicle fractures using fracture-specific plates and coracoclavicular augmentation with a suture button. Six patients with clinically unstable type II distal clavicle fractures underwent treatment using the above technique. All fractures demonstrated radiographic union at 9.6 (8.4-11.6) weeks with a mean follow-up of 15.6 (12.4-22.3) months. American Shoulder and Elbow Surgeons, Penn Shoulder Score, and Single Assessment Numeric Evaluation scores were 97.97 (98.33-100), 96.4 (91-99), and 95 (90-100), respectively. One patient required implant removal. Fracture-specific plating with suture-button augmentation for type II distal clavicle fractures provides reliable rates of union without absolute requirement for implant removal.
Investigation of low temperature solid oxide fuel cells for air-independent UUV applications
NASA Astrophysics Data System (ADS)
Moton, Jennie Mariko
Unmanned underwater vehicles (UUVs) will benefit greatly from high energy density (> 500 Wh/L) power systems utilizing high-energy-density fuels and air-independent oxidizers. Current battery-based systems have limited energy densities (< 400 Wh/L), which motivate development of alternative power systems such as solid oxide fuel cells (SOFCs). SOFC-based power systems have the potential to achieve the required UUV energy densities, and the current study explores how SOFCs based on gadolinia-doped ceria (GDC) electrolytes with operating temperatures of 650°C and lower may operate in the unique environments of a promising UUV power plant. The plant would contain a H 2O2 decomposition reactor to supply humidified O2 to the SOFC cathode and exothermic aluminum/H2O combustor to provide heated humidified H2 fuel to the anode. To characterize low-temperature SOFC performance with these unique O2 and H2 source, SOFC button cells based on nickel/GDC (Gd0.1Ce0.9O 1.95) anodes, GDC electrolytes, and lanthanum strontium cobalt ferrite (La0.6Sr0.4Co0.2Fe0.8O3-δ or LSCF)/GDC cathodes were fabricated and tested for performance and stability with humidity on both the anode and the cathode. Cells were also tested with various reactant concentrations of H2 and O2 to simulate gas depletion down the channel of an SOFC stack. Results showed that anode performance depended primarily on fuel concentration and less on the concentration of the associated increase in product H2O. O 2 depletion with humidified cathode flows also caused significant loss in cell current density at a given voltage. With the humidified flows in either the anode or cathode, stability tests of the button cells at 650 °C showed stable voltage is maintained at low operating current (0.17 A/cm2) at up to 50 % by mole H2O, but at higher current densities (0.34 A/cm2), irreversible voltage degradation occurred at rates of 0.8-3.7 mV/hour depending on exposure time. From these button cell results, estimated average current densities over the length of a low-temperature SOFC stack were estimated and used to size a UUV power system based on Al/H 2O oxidation for fuel and H2O2 decomposition for O2. The resulting system design suggested that energy densities above 300 Wh/L may be achieved at neutral buoyancy with seawater if the cell is operated at high reactant utilizations in the SOFC stack for missions longer than 20 hours.
USDA-ARS?s Scientific Manuscript database
Previously we showed that mice fed white button mushrooms (WBM) had enhanced immune functions known to help the body’s antiviral defense. In this study, we tested if WBM could afford protection against viral infection. Young (4-mo) and old (22-mo) C57BL/6 mice were fed a diet containing 0, 2 per cen...
McCaughey, Conor; Tsakiropoulos, Panos
2018-06-07
The Nb-silicide-based alloy of near eutectic composition (at.%) Nb-21.1Si-8.3Ti-5.4Mo-4W-0.7Hf (alloy CM1) was studied in the cast and heat-treated (1500 °C/100 h) conditions. The alloy was produced in the form of buttons and bars using three different methods, namely arc-melting, arc-melting and suction casting, and optical floating zone (OFZ) melting. In the former two cases the alloy solidified in water-cooled copper crucibles. Buttons and suction-cast bars of different size, respectively of 10 g and 600 g weight and 6 mm and 8 mm diameter, were produced. The OFZ bars were grown at three different growth rates of 12, 60 and 150 mm/h. It was confirmed that the type of Nb₅Si₃ formed in the cast microstructures depended on the solidification conditions. The primary phase in the alloy CM1 was the βNb₅Si₃. The transformation of βNb₅Si₃ to αNb₅Si₃ had occurred in the as cast large size button and the OFZ bars grown at the three different growth rates, and after the heat treatment of the small size button and the suction-cast bars of the alloy. This transformation was accompanied by subgrain formation in Nb₅Si₃ and the precipitation of Nb ss in the large size as cast button and only by the precipitation of Nb ss in the cast OFZ bars. Subgrains and precipitation of Nb ss in αNb₅Si₃ was observed in the small size button and suction-cast bars after the heat treatment. Subgrains formed in αNb₅Si₃ after the heat treatment of the OFZ bars. The partitioning of solutes and in particular of Mo and Ti was key to this phase transformation. Subgrain formation was not necessary for precipitation of Nb ss in αNb₅Si₃, but the partitioning of solutes was essential for this precipitation.
Congenital Syphilis Masquerading as Leukemia.
Lee, Tiffany; Bell, Stephanie; Scimeme, Jason; Maraqa, Nizar
2017-07-01
As of late, the incidence of congenital syphilis in the United States is increasing. Each new case represents a failure of preventing, diagnosing, and treating syphilis in pregnant women. Pediatricians should confirm that all women have received adequate screening for and management of syphilis during pregnancy. Congenital syphilis is easily treatable but may be a diagnostic challenge with high morbidity and mortality.
ERIC Educational Resources Information Center
Belshaw, Michael
2011-01-01
Not so long ago the occasional story would be told in the news that someone with a fascination for all things medical had spent months or even years masquerading as a doctor in a large and anonymous hospital. No doubt the absence of such stories today is due to heightened security and vigilance, partly as a result of the realization among hospital…
[Moxiflaxin and iris transillumination].
Broens, A; Collignon, N
2016-07-01
Bilateral Acute Iris Transillumination (BAIT) is a new clinical entity characterized by acute onset of pigment dispersion in the anterior chamber and angle, depigmentation of the iris stroma and permanent iris transillumination, masquerading as uveitis. An association with oral moxifloxacin is reported in some articles. We describe one case of bilateral acute iris transillumination, following the use of systemic moxifloxacin.
Oak, Nikhil R; Lien, John R; Brunfeldt, Alexander; Lawton, Jeffrey N
2018-05-01
A fracture through the proximal radius is a theoretical concern after cortical button distal biceps fixation in an active patient. The permanent, nonossified cortical defect and medullary tunnel is at risk during a fall eliciting rotational and compressive forces. We hypothesized that during simulated torsion and compression, in comparison with unaltered specimens, the cortical button distal biceps repair model would have decreased torsional and compressive strength and would fracture in the vicinity of the bicipital tuberosity bone tunnel. Sixteen fourth-generation composite radius Sawbones models were used in this controlled laboratory study. A bone tunnel was created through the bicipital tuberosity to mimic the exact bone tunnel, 8 mm near cortex and 3.2 mm far cortex, made for the BicepsButton distal biceps tendon repair. The radius was then prepared and mounted on either a torsional or compression testing device and compared with undrilled control specimens. Compression tests resulted in average failure loads of 9015.2 N in controls versus 8253.25 N in drilled specimens ( P = .074). Torsional testing resulted in an average failure torque of 27.3 Nm in controls and 19.3 Nm in drilled specimens ( P = .024). Average fracture angle was 35.1° in controls versus 21.1° in drilled. Gross fracture patterns were similar in compression testing; however, in torsional testing all fractures occurred through the bone tunnel in the drilled group. There are weaknesses in the vicinity of the bone tunnel in the proximal radius during biomechanical stress testing which may not be clinically relevant in nature. In cortical button fixation, distal biceps repairs creates a permanent, nonossified cortical defect with tendon interposed in the bone tunnel, which can alter the biomechanical properties of the proximal radius during compressive and torsional loading.
Field comparison of three inhalable samplers (IOM, PGP-GSP 3.5 and Button) for welding fumes.
Zugasti, Agurtzane; Montes, Natividad; Rojo, José M; Quintana, M José
2012-02-01
Inhalable sampler efficiency depends on the aerodynamic size of the airborne particles to be sampled and the wind speed. The aim of this study was to compare the behaviour of three personal inhalable samplers for welding fumes generated by Manual Metal Arc (MMA) and Metal Active Gas (MAG) processes. The selected samplers were the ones available in Spain when the study began: IOM, PGP-GSP 3.5 (GSP) and Button. Sampling was carried out in a welding training center that provided a homogeneous workplace environment. The static sampling assembly used allowed the placement of 12 samplers and 2 cascade impactors simultaneously. 183 samples were collected throughout 2009 and 2010. The range of welding fumes' mass concentrations was from 2 mg m(-3) to 5 mg m(-3). The pooled variation coefficients for the three inhalable samplers were less than or equal to 3.0%. Welding particle size distribution was characterized by a bimodal log-normal distribution, with MMADs of 0.7 μm and 8.2 μm. For these welding aerosols, the Button and the GSP samplers showed a similar performance (P = 0.598). The mean mass concentration ratio was 1.00 ± 0.01. The IOM sampler showed a different performance (P < 0.001). The mean mass concentration ratios were 0.90 ± 0.01 for Button/IOM and 0.92 ± 0.02 for GSP/IOM. This information is useful to consider the measurements accomplished by the IOM, GSP or Button samplers together, in order to assess the exposure at workplaces over time or to study exposure levels in a specific industrial activity, as welding operations.
Anterior capsulotomy with an ultrashort-pulse laser.
Tackman, Ramon Naranjo; Kuri, Jorge Villar; Nichamin, Louis D Skip; Edwards, Keith
2011-05-01
To assess the precision of laser anterior capsulotomy compared with that of manual continuous curvilinear capsulorhexis (CCC). Asociación Para Evitar La Ceguera en México IAP, Hospital Dr. Luis Sánchez Bulnes, Mexico City, Mexico. Nonrandomized single-center clinical trial. In patients presenting for cataract surgery, the LensAR Laser System was used to create a laser anterior capsulotomy of the surgeon's desired size. Capsule buttons were retrieved and measured and then compared with buttons retrieved from eyes having a manually torn CCC. Deviation from the intended diameter and the regularity of shape were assessed. When removing the capsule buttons at the start of surgery, the surgeon rated the ease of removal on a scale of 1 to 10 (1 = required manual capsulorhexis around the whole diameter; 10 = button free floating or required no manual detachment from remaining capsule during removal). The mean deviation from the intended diameter was 0.16 mm ± 0.17 (SD) for laser anterior capsulotomy and 0.42 ± 0.54 mm for CCC (P=.03). The mean absolute deviation from the intended diameter was 0.20 ± 0.12 mm and 0.49 ± 0.47 mm, respectively (P=.003). The mean of the average squared residuals was 0.01 ± 0.03 and 0.02 ± 0.04, respectively (P=.09). The median rating of the ease of removal was 9 (range 5 to 10). Laser anterior capsulotomy created a more precise capsule opening than CCC, and the buttons created by the laser procedure were easy to remove at the beginning of cataract surgery. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Batterman, Jared M; Martin, Vincent F; Yeung, Derek; Walker, Bruce N
2018-01-01
Accessibility of assistive consumer devices is an emerging research area with potential to benefit both users with and without visual impairments. In this article, we discuss the research and evaluation of using a tactile button interface to control an iOS device's native VoiceOver Gesture navigations (Apple Accessibility, 2014). This research effort identified potential safety and accessibility issues for users trying to interact and control their touchscreen mobile iOS devices while traveling independently. Furthermore, this article discusses the participatory design process in creating a solution that aims to solve issues in utilizing a tactile button interface in a novel device. The overall goal of this study is to enable visually impaired white cane users to access their mobile iOS device's capabilities navigation aids more safely and efficiently on the go.
Increasing smoke alarm operability through theory-based health education: a randomised trial
Miller, Ted R; Bergen, Gwen; Ballesteros, Michael F; Bhattacharya, Soma; Gielen, Andrea Carlson; Sheppard, Monique S
2015-01-01
Background Although working smoke alarms halve deaths in residential fires, many households do not keep alarms operational. We tested whether theory-based education increases alarm operability. Methods Randomised multiarm trial, with a single arm randomly selected for use each day, in low-income neighbourhoods in Maryland, USA. Intervention arms: (1) Full Education combining a health belief module with a social-cognitive theory module that provided hands-on practice installing alarm batteries and using the alarm’s hush button; (2) Hands-on Practice social-cognitive module supplemented by typical fire department education; (3) Current Norm receiving typical fire department education only. Four hundred and thirty-six homes recruited through churches or by knocking on doors in 2005–2008. Followup visits checked alarm operability in 370 homes (85%) 1–3.5 years after installation. Main outcome measures: number of homes with working alarms defined as alarms with working batteries or hard-wired and number of working alarms per home. Regressions controlled for alarm status preintervention; demographics and beliefs about fire risks and alarm effectiveness. Results Homes in the Full Education and Practice arms were more likely to have a functioning smoke alarm at follow-up (OR=2.77, 95% CI 1.09 to 7.03) and had an average of 0.32 more working alarms per home (95% CI 0.09 to 0.56). Working alarms per home rose 16%. Full Education and Practice had similar effectiveness (p=0.97 on both outcome measures). Conclusions Without exceeding typical fire department installation time, installers can achieve greater smoke alarm operability. Hands-on practice is key. Two years after installation, for every three homes that received hands-on practice, one had an additional working alarm. Trial registration number http://www.clinicaltrials.gov number NCT00139126. PMID:25165090
Handheld Metal Detector for Metallic Foreign Body Ingestion in Pediatric Emergency.
Hamzah, Hazwani Binte; James, Vigil; Manickam, Suraj; Ganapathy, Sashikumar
2018-01-04
Foreign body ingestion is a common problem for which children present to the emergency department. The most common ingested foreign bodies among children are coins. Metal detector is an equipment, which measures a change in inductance of a coil when an electroconductive material is placed near it and produces an audio-visual signal. The present study was conducted to determine the effectiveness and feasibility of HMD in the local Pediatric population. This was a prospective study conducted in the pediatric emergency department among children presenting with history of foreign body ingestion. The outcome measured was presence or absence of metallic foreign body detected on handheld metal detector examination. During the study period, 36 patients with history of foreign body ingestion presented to the emergency department. Among these, 28 were metallic foreign body ingestions. Coins were the most common type of foreign body ingested. Among the metallic foreign bodies ingested, all the coins were accurately identified by the handheld metal detector. Non-coin metallic foreign bodies like metallic screw, needle and stapler pin were not identified by the handheld metal detector. The study demonstrates that handheld metal detector can be safely and reliably used as a screening tool in the process of detecting ingested coins. The plain radiograph still appears to be superior as it accurately localizes sharp metallic objects as well as cell batteries (button batteries) which need to be detected early and removed in order to prevent complications. Handheld metal detector is an effective tool that can be used in the follow up of patients to confirm whether the coin like metallic foreign body has been expelled. Handheld metal detector examination is more sensitive than traditional X-ray examination to detect radiolucent metallic foreign bodies like aluminium.
NASA Technical Reports Server (NTRS)
De Luca, Gianluca; De Luca, Carlo J.; Bergman, Per
2004-01-01
A portable electronic apparatus records electromyographic (EMG) signals in as many as 16 channels at a sampling rate of 1,024 Hz in each channel. The apparatus (see figure) includes 16 differential EMG electrodes (each electrode corresponding to one channel) with cables and attachment hardware, reference electrodes, an input/output-and-power-adapter unit, a 16-bit analog-to-digital converter, and a hand-held computer that contains a removable 256-MB flash memory card. When all 16 EMG electrodes are in use, full-bandwidth data can be recorded in each channel for as long as 8 hours. The apparatus is powered by a battery and is small enough that it can be carried in a waist pouch. The computer is equipped with a small screen that can be used to display the incoming signals on each channel. Amplitude and time adjustments of this display can be made easily by use of touch buttons on the screen. The user can also set up a data-acquisition schedule to conform to experimental protocols or to manage battery energy and memory efficiently. Once the EMG data have been recorded, the flash memory card is removed from the EMG apparatus and placed in a flash-memory- card-reading external drive unit connected to a personal computer (PC). The PC can then read the data recorded in the 16 channels. Preferably, before further analysis, the data should be stored in the hard drive of the PC. The data files are opened and viewed on the PC by use of special- purpose software. The software for operation of the apparatus resides in a random-access memory (RAM), with backup power supplied by a small internal lithium cell. A backup copy of this software resides on the flash memory card. In the event of loss of both main and backup battery power and consequent loss of this software, the backup copy can be used to restore the RAM copy after power has been restored. Accessories for this device are also available. These include goniometers, accelerometers, foot switches, and force gauges.
Is the Go/No-Go Lexical Decision Task Preferable to the Yes/No Task with Developing Readers?
ERIC Educational Resources Information Center
Moret-Tatay, Carmen; Perea, Manuel
2011-01-01
The lexical decision task is probably the most common laboratory visual word identification task together with the naming task. In the usual setup, participants need to press the "yes" button when the stimulus is a word and the "no" button when the stimulus is not a word. A number of studies have employed this task with developing readers;…
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCracken, Brewster
Through funding from the Department of Energy’s Electricity Delivery and Reliability Office, Pecan Street Inc., in partnership with Austin Energy and Oncor, developed and tested third- party data access platforms and services for Green Button offerings and for other home energy use data providers. As more utilities seek to offer Green Button-compliant data to their customers, the question continually arises of how this data can be used to help customers better manage their energy use.
ERIC Educational Resources Information Center
Vairo, Philip D.; Marcus, Sheldon; Weiner, Max
2007-01-01
One of the tragedies of American education is that so many teachers do not understand or are unaware of educational issues and how they impact on their profession. There is a gap between teacher perceptions and reality and this book is a first step in closing that gap. Hot-Button Issues for Teachers is a timely, comprehensive book that addresses…
Supplemental Archeological Investigations of Lower Bayou Teche, St. Mary Parish, Louisiana
1991-08-01
Ruler end (brass)1 ____ Buckle 1__________ Brass and inlaid shell button 1____ Chain 2 71 Cosmetic cap - gild brass inlaid with shell 1I____ 185...Molded stemnware fragment ____ _____ _____ Unidentified ______ ______1 Perfume/ Cosmetic Bottle Fragment Milk glass 2 Melted Glass Aqua1 Unidentified...major portion of the recovery (n = 122). Other metal artifacts included 2 safety pins, 1 cosmetic cap made of gilt brass inlaid with shell, 3 buttons
NASA Astrophysics Data System (ADS)
Ishak, Muhamad Safwan; Sahid, Ismail
2014-09-01
A laboratory experiment was conducted to study the allelopathic effects of the aqueous extract of the leaf and seed of Leucaena leucocephala. The aqueous extracts were individually tested on three selected weed species, namely goatweed (Ageratum conyzoides), coat buttons (Tridax procumbens) and lilac tasselflower (Emilia sonchifolia). The allelopathic effects of the leaf and seed extracts on germination, shoot length, root length and fresh weight of each of the selected weed species were determined. Germination of goatweed, coat buttons and lilac tasselflower were inhibited by the aqueous extracts of both the leaf and seed of L. leucocephala and was concentration dependent. Different concentrations of the aqueous extracts showed various germination patterns on the selected weeds species. Seedling length and fresh weight of goatweed, coat buttons and lilac tasselflower were reduced in response to respective increasing concentrations of the seed extracts. Maximum inhibition by the aqueous seed extract was observed more on the root rather than the shoot growth. The aqueous seed extract at T3 concentration reduced root length of goatweed, coat buttons and lilac tasselflower by 95%, 86% and 91% (of the control) respectively. The aqueous seed extract showed greater inhibitory effects than that of the aqueous leaf extract.
Modified coaxial wire method for measurement of transfer impedance of beam position monitors
NASA Astrophysics Data System (ADS)
Kumar, Mukesh; Babbar, L. K.; Deo, R. K.; Puntambekar, T. A.; Senecha, V. K.
2018-05-01
The transfer impedance is a very important parameter of a beam position monitor (BPM) which relates its output signal with the beam current. The coaxial wire method is a standard technique to measure transfer impedance of the BPM. The conventional coaxial wire method requires impedance matching between coaxial wire and external circuits (vector network analyzer and associated cables). This paper presents a modified coaxial wire method for bench measurement of the transfer impedance of capacitive pickups like button electrodes and shoe box BPMs. Unlike the conventional coaxial wire method, in the modified coaxial wire method no impedance matching elements have been used between the device under test and the external circuit. The effect of impedance mismatch has been solved mathematically and a new expression of transfer impedance has been derived. The proposed method is verified through simulation of a button electrode BPM using cst studio suite. The new method is also applied to measure transfer impedance of a button electrode BPM developed for insertion devices of Indus-2 and the results are also compared with its simulations. Close agreement between measured and simulation results suggests that the modified coaxial wire setup can be exploited for the measurement of transfer impedance of capacitive BPMs like button electrodes and shoe box BPM.
Distinct dynamical patterns that distinguish willed and forced actions.
Garcia Dominguez, Luis; Kostelecki, Wojciech; Wennberg, Richard; Perez Velazquez, Jose L
2011-03-01
The neural pathways for generating willed actions have been increasingly investigated since the famous pioneering work by Benjamin Libet on the nature of free will. To better understand what differentiates the brain states underlying willed and forced behaviours, we performed a study of chosen and forced actions over a binary choice scenario. Magnetoencephalography recordings were obtained from six subjects during a simple task in which the subject presses a button with the left or right finger in response to a cue that either (1) specifies the finger with which the button should be pressed or (2) instructs the subject to press a button with a finger of their own choosing. Three independent analyses were performed to investigate the dynamical patterns of neural activity supporting willed and forced behaviours during the preparatory period preceding a button press. Each analysis offered similar findings in the temporal and spatial domains and in particular, a high accuracy in the classification of single trials was obtained around 200 ms after cue presentation with an overall average of 82%. During this period, the majority of the discriminatory power comes from differential neural processes observed bilaterally in the parietal lobes, as well as some differences in occipital and temporal lobes, suggesting a contribution of these regions to willed and forced behaviours.
Double-button Fixation System for Management of Acute Acromioclavicular Joint Dislocation
Torkaman, Ali; Bagherifard, Abolfazl; Mokhatri, Tahmineh; Haghighi, Mohammad Hossein Shabanpour; Monshizadeh, Siamak; Taraz, Hamid; Hasanvand, Amin
2016-01-01
Background: Surgical treatments for acromioclavicular (AC) joint dislocation present with some complications. The present study was designed to evaluate the double-button fixation system in the management of acute acromioclavicular joint dislocation. Methods: This cross sectional study, done between February 2011 to June 2014, consisted of 28 patients who underwent surgical management by the double-button fixation system for acute AC joint dislocation. Age, sex, injury mechanism, dominant hand, side with injury, length of follow up, time before surgery, shoulder and hand (DASH), constant and visual analogue scale (VAS) scores, and all complications of the cases during the follow up were recorded. Results: The mean age of patients was 33.23±6.7 years. Twenty four patients (85.71%) were male and four (14.28%) were female. The significant differences were observed between pre-operation VAS, constant shoulder scores and post-operation measurements. There were not any significant differences between right and left coracoclavicular, but two cases of heterotrophic ossifications were recorded. The mean follow-up time was 16.17±4.38 months. Conclusion: According to the results, the double-button fixation system for management of acute acromioclavicular joint dislocation has suitable results and minimal damage to the soft tissues surrounding the coracoclavicular ligaments. PMID:26894217
Neyton, Lionel; Barth, Johannes; Nourissat, Geoffroy; Métais, Pierre; Boileau, Pascal; Walch, Gilles; Lafosse, Laurent
2018-05-19
To analyze graft and fixation (screw and EndoButton) positioning after the arthroscopic Latarjet technique with 2-dimensional computed tomography (CT) and to compare it with the open technique. We performed a retrospective multicenter study (March 2013 to June 2014). The inclusion criteria included patients with recurrent anterior instability treated with the Latarjet procedure. The exclusion criterion was the absence of a postoperative CT scan. The positions of the hardware, the positions of the grafts in the axial and sagittal planes, and the dispersion of values (variability) were compared. The study included 208 patients (79 treated with open technique, 87 treated with arthroscopic Latarjet technique with screw fixation [arthro-screw], and 42 treated with arthroscopic Latarjet technique with EndoButton fixation [arthro-EndoButton]). The angulation of the screws was different in the open group versus the arthro-screw group (superior, 10.3° ± 0.7° vs 16.9° ± 1.0° [P < .001]; inferior, 10.3° ± 0.8° vs 15.7° ± 0.9° [P < .0001]). The angulation of the EndoButtons was 5.7° ± 0.5°; this was different from that of open inferior screws (P = .003). In the axial plane (level of equator), the arthroscopic techniques resulted in lateral positions (arthro-screw, 1.5 ± 0.3 mm lateral [P < .001]; arthro-EndoButton, 0 ± 0.3 mm lateral [P < .0001]) versus the open technique (0.9 ± 0.2 mm medial). At the level of 25% of the glenoid height, the arthroscopic techniques resulted in lateral positions (arthro-screw, 0.3 ± 0.3 mm lateral [P < .001]); (arthro-EndoButton, 0.7 ± 0.3 mm lateral [P < .0001]) versus the open technique (1.0 ± 0.2 mm medial). Higher variability was observed in the arthro-screw group. In the sagittal plane, the arthro-screw technique resulted in higher positions (55% ± 3% of graft below equator) and the arthro-EndoButton technique resulted in lower positions (82% ± 3%, P < .0001) versus the open technique (71% ± 2%). Variability was not different. This study shows that the position of the fixation devices and position of the bone graft with the arthroscopic techniques are statistically significantly different from those with the open technique with 2-dimensional CT assessment. In the sagittal plane, the arthro-screw technique provides the highest positions, and the arthro-EndoButton technique, the lowest. Overall, the mean position of the bone block with the open Latarjet technique in the axial plane is slightly medial to the joint line, as recommended. Conversely, with the arthroscopic techniques, the bone grafts are more lateral with a slight overhang. The main differences are observed in the dispersion of the values (more extreme positions) with the arthro-screw technique, given the acknowledged limitations. Despite the statistical significance, the clinical significance of these differences is yet unknown. Level III, retrospective comparative study. Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Zekavat, Omid Reza; Abdolkarimi, Babak; Pouladfar, Gholamreza; Fathpour, Gholamreza; Mokhtari, Maral; Shakibazad, Nader
2017-01-01
Basidiobolomycosis is an unusual fungal skin infection that rarely involves the gastrointestinal tract. This study reported a 5-year-old boy with gastrointestinal basidiobolomycosis that had been misdiagnosed as gastrointestinal lymphoma. He was treated by surgical resection and a combination of posaconazole and amphotericin B deoxycholate with an acceptable response and no recurrence.
Reduction of Photodiode Nonlinearities by Adaptive Biasing
2016-10-14
2016 Approved for public release; distribution is unlimited. Meredith N. hutchiNsoN Nicholas J. Frigo Photonics Technology Branch Optical Sciences...Unclassified Unlimited Unclassified Unlimited 19 Meredith N. Hutchinson (202) 767-9549 Fiber optics Analog photonics RF photonic links impress information...to nonlinearities. These spurious tones masquerade as signals and impair the performance of the photonic link. Earlier research has shown the
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blaschke, David; Instytut Fizyki Teoretycznej, Uniwersytet Wroclawski, 50-204 Wroclaw; Alvarez-Castillo, David E.
2016-01-22
We aim at contributing to the resolution of three of the fundamental puzzles related to the still unsolved problem of the structure of the dense core of compact stars (CS): (i) the hyperon puzzle: how to reconcile pulsar masses of 2 M{sub ⊙} with the hyperon softening of the equation of state (EoS); (ii) the masquerade problem: modern EoS for cold, high density hadronic and quark matter are almost identical; and (iii) the reconfinement puzzle: what to do when after a deconfinement transition the hadronic EoS becomes favorable again? We show that taking into account the compositeness of baryons (bymore » excluded volume and/or quark Pauli blocking) on the hadronic side and confining and stiffening effects on the quark matter side results in an early phase transition to quark matter with sufficient stiffening at high densities which removes all three present-day puzzles of CS interiors. Moreover, in this new class of EoS for hybrid CS falls the interesting case of a strong first order phase transition which results in the observable high mass twin star phenomenon, an astrophysical observation of a critical endpoint in the QCD phase diagram.« less
Carcinoma transverse colon masquerading as carcinoma gall bladder
Kumar, Ashwani; Singh, Harnam; Singh, Gurpreet; Singh, Bimaljot; Chauhan, Mahak
2014-01-01
Colorectal cancer is one of the most common cancer worldwide .Its incidence is reported to be increasing in developing countries. It commonly presents with weight loss, anaemia, lump abdomen, change of bowel habit, obstruction or fresh rectal bleeding. Beside these common modes of presentations, there are some rare manifestations which masqueraded as different disease like obstructive jaundice, empyema gall bladder or cholecystitis. A 60-year-old male presented to hospital with right sided pain abdomen. On abdominal examination mild tenderness was present in right hypochondrium. Intra operatively gall bladder was separated from the adjoining gut, peritoneum and liver bed and was removed. On further exploration, there was a large mass in the vicinity of the gall bladder related to transverse colon. Extended right hemicolectomy was done. Histopathological examination of gut mass revealed adenocarcinoma of transverse colon with free margins and gall bladder showed cholecystitis with no evidence of malignancy. We present an interesting case of colon cancer colon that caused diagnostic confusion by mimicking as cholecystitis. Colorectal cancer constitutes a major public health issue globally. Therefore, public awareness, screening of high-risk populations, early diagnosis and effective treatment and follow-up will help to reduce its occurance and further complications. PMID:24772345
Carcinoma transverse colon masquerading as carcinoma gall bladder.
Munghate, Anand; Kumar, Ashwani; Singh, Harnam; Singh, Gurpreet; Singh, Bimaljot; Chauhan, Mahak
2014-04-01
Colorectal cancer is one of the most common cancer worldwide .Its incidence is reported to be increasing in developing countries. It commonly presents with weight loss, anaemia, lump abdomen, change of bowel habit, obstruction or fresh rectal bleeding. Beside these common modes of presentations, there are some rare manifestations which masqueraded as different disease like obstructive jaundice, empyema gall bladder or cholecystitis. A 60-year-old male presented to hospital with right sided pain abdomen. On abdominal examination mild tenderness was present in right hypochondrium. Intra operatively gall bladder was separated from the adjoining gut, peritoneum and liver bed and was removed. On further exploration, there was a large mass in the vicinity of the gall bladder related to transverse colon. Extended right hemicolectomy was done. Histopathological examination of gut mass revealed adenocarcinoma of transverse colon with free margins and gall bladder showed cholecystitis with no evidence of malignancy. We present an interesting case of colon cancer colon that caused diagnostic confusion by mimicking as cholecystitis. Colorectal cancer constitutes a major public health issue globally. Therefore, public awareness, screening of high-risk populations, early diagnosis and effective treatment and follow-up will help to reduce its occurance and further complications.
Bradley, Amanda; Estes, Amy; Ulrich, Lane; Thomas, Dilip; Gay, David
2017-02-01
We report a 75-year-old woman with a history of multiple myeloma immunoglobulin D (IgD) variant, who presented with an epibulbar plasmacytoma masquerading as a subconjunctival hemorrhage. Magnetic resonance imaging of the brain and orbits with and without contrast was obtained and surgical biopsy of the subconjunctival lesion was performed; histopathology confirmed the diagnosis of plasmacytoma. Subconjunctival biopsy revealed a plasma cell neoplasm infiltrate in the episcleral layer. The subconjunctival biopsy stained positive for CD138 and lambda-immunohistochemistry in the majority of plasma cells. Histologic findings were consistent with involvement by known IgD plasma cell myeloma where previous bone marrow biopsy demonstrated myeloma cells which stained monoclonally for IgD-lambda light chains. Although plasma cell neoplasms seldom present with ocular manifestations, it is crucial to recognize that these tumors may be associated with multiple myeloma. In patients with known multiple myeloma who present with subconjunctival hemorrhage, close follow-up is highly recommended, as this may be the initial presentation of an ocular plasmacytoma. Although a plasmacytoma is a rare subconjunctival lesion, it should not be immediately excluded from the differential diagnosis of such lesions.
Thomas, Andrew J; Wiggins, Richard H; Gurgel, Richard K
2017-08-01
To describe a case of metastatic renal cell carcinoma (RCC) masquerading as a jugular foramen paraganglioma (JP). To compare imaging findings between skull base metastatic RCC and histologically proven paraganglioma. A case of unexpected metastatic skull base RCC is reviewed. Computed tomography (CT) and magnetic resonance imaging (MRI) were compared between 3 confirmed cases of JP and our case of metastatic RCC. Diffusion-weighted MRI (DW-MRI) sequences and computed apparent diffusion coefficient (ADC) values were compared between these entities. A 55-year-old man presents with what appears clinically and radiographically to be JP. The tumor was resected, then discovered on postoperative pathology to be metastatic RCC. Imaging was retrospectively compared between 3 histologically confirmed cases of JP and our case of skull base RCC. The RCC metastasis was indistinguishable from JP on CT and traditional MRI but distinct by ADC values calculated from DW-MRI. Metastatic RCC at the skull base may mimic the clinical presentation and radiographic appearance of JP. The MRI finding of flow voids is seen in both paraganglioma and metastatic RCC. Diffusion-weighted MRI is able to distinguish these entities, highlighting its potential utility in distinguishing skull base lesions.
Scabies masquerading as bullous pemphigoid: scabies surrepticius
Cohen, Philip R
2017-01-01
Scabies, a parasitic infestation caused by the mite Sarcoptes scabiei, is diagnosed by observing either the mite, its ova, or its excrement. The mite tracts, known as burrows and a characteristic presentation of the pruritic condition, are typically found on the web spaces between the fingers. Other cutaneous lesions include excoriated papules, pustules, and vesicles. However, atypical clinical variants of scabies, such as bullous, crusted, hidden, incognito, nodular, and scalp forms of the parasitic infestation, mimic the morphologic features of other non-parasitic dermatoses. A 76-year-old man presented with pruritic blisters and urticarial plaques that demonstrated not only pathology changes, but direct immunofluorescence also showed findings of bullous pemphigoid. His condition improved, but did not resolve, with topical corticosteroid cream for the management of the primary autoimmune blistering disorder. When other family members subsequently developed scabies, the correct diagnosis for his condition, bullous scabies, was established by demonstrating mites, ova, and scybala on a mineral oil preparation from a skin scraping of a newly appearing burrow. Bullous scabies can masquerade not only clinically, but also both pathologically and immunologically as bullous pemphigoid. Scabies serrupticius is introduced as a unifying term to designate all of the non-classic presentations of S. scabiei mite infestation. PMID:28883737
A Study of Selected Problems in Armor Operations
1978-11-01
of external environmental cond~tions on the internal environment of a buttoned-up tank. Another effort was a study of problems in escape and...Test site configuration: Study II ......... ... IV-16 FIG. IVT4. Mean time to lay on target .... ........ .... IV-20 TABLES Chapter III Table III-I...L., and Ton, W. H. Study of the Psychological (and Associated Physiological) Effjcts on a Tank Crew Resulting From Being Buttoned Up, ARI Research
BPM Breakdown Potential in the PEP-II B-factory Storage Ring Collider
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weathersby, Stephen; Novokhatski, Alexander; /SLAC
2010-02-10
High current B-Factory BPM designs incorporate a button type electrode which introduces a small gap between the button and the beam chamber. For achievable currents and bunch lengths, simulations indicate that electric potentials can be induced in this gap which are comparable to the breakdown voltage. This study characterizes beam induced voltages in the existing PEP-II storage ring collider BPM as a function of bunch length and beam current.
Consortium Requirements Engineering Guidebook
1993-12-01
re- quirements among developers or contractors, acquisition managers, and users. A CoRE specification serves as both the test -to and design-to...that are used for the following purposes: (1) the button labeled SELF TEST allows the operator to check the FLMS’s output hardware while the system is...shut down; and (2) the button labeled RESET allows the system to be brought back into normal operation following a shutdown or testing as long as the
An ergonomics study of thumb movements on smartphone touch screen.
Xiong, Jinghong; Muraki, Satoshi
2014-01-01
This study investigated the relationships between thumb muscle activity and thumb operating tasks on a smartphone touch screen with one-hand posture. Six muscles in the right thumb and forearm were targeted in this study, namely adductor pollicis, flexor pollicis brevis, abductor pollicis brevis (APB), abductor pollicis longus, first dorsal interosseous (FDI) and extensor digitorum. The performance measures showed that the thumb developed fatigue rapidly when tapping on smaller buttons (diameter: 9 mm compared with 3 mm), and moved more slowly in flexion-extension than in adduction-abduction orientation. Meanwhile, the electromyography and perceived exertion values of FDI significantly increased in small button and flexion-extension tasks, while those of APB were greater in the adduction-abduction task. This study reveals that muscle effort among thumb muscles on a touch screen smartphone varies according to the task, and suggests that the use of small touch buttons should be minimised for better thumb performance.
A wire scanner system for characterizing the BNL energy recovery LINAC beam position monitor system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Michnoff R.; Biscardi, C.; Cerniglia, P.
2012-04-15
A stepper motor controlled wire scanner system has recently been modified to support testing of the Brookhaven National Laboratory (BNL) Collider-Accelerator department's Energy Recovery Linac (ERL) beam position monitor (BPM) system. The ERL BPM consists of four 9.33 mm diameter buttons mounted at 90 degree spacing in a cube with 1.875 inch inside diameter. The buttons were designed by BNL and fabricated by Times Microwave Systems. Libera brilliance single pass BPM electronic modules with 700 MHz bandpass filter, manufactured by Instrumentation Technologies, will be used to measure the transverse beam positions at 14 locations around the ERL. The wire scannermore » assembly provides the ability to measure the BPM button response to a pulsed wire, and evaluate and calibrate the Libera position measurement electronics. A description of the wire scanner system and test result data will be presented.« less
1992-02-01
467 Table 4 Personal Items from Shovel Tests, 160R130. SURF SURF SURF N15 N5 NO NO $5 S5 1 2 3 W20 El5 E20 W10 E20 EO Bone button, Type B-5 Ceramic...Table 4 . Personal Items from Shovel Tests, 160R130. S15 S20 S20 S25 S25 S30 S30 S30 S32.5 E5 E35 E20 E50 E25 E50 E35 E20 E35 Bone button, Type B-5...1 1 1 7 1 471 Table 4 Personal Items from Shovel Tests, 160R130. S30 S34 S35 S45 S50 TOTAL El0 E35 E30 E30 E55 Bone button, Type B-5 1 1 Ceramic
Paper-based piezoelectric touch pads with hydrothermally grown zinc oxide nanowires.
Li, Xiao; Wang, Yu-Hsuan; Zhao, Chen; Liu, Xinyu
2014-12-24
This paper describes a new type of paper-based piezoelectric touch pad integrating zinc oxide nanowires (ZnO NWs), which can serve as user interfaces in paper-based electronics. The sensing functionality of these touch pads is enabled by the piezoelectric property of ZnO NWs grown on paper using a simple, cost-efficient hydrothermal method. A piece of ZnO-NW paper with two screen-printed silver electrodes forms a touch button, and touch-induced electric charges from the button are converted into a voltage output using a charge amplifier circuit. A touch pad consisting of an array of buttons can be readily integrated into paper-based electronic devices, allowing user input of information for various purposes such as programming, identification checking, and gaming. This novel design features ease of fabrication, low cost, ultrathin structure, and good compatibility with techniques in printed electronics, and further enriches the available technologies of paper-based electronics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hagans, K.G.; Clough, R.E.
2000-04-25
An optical key system comprises a battery-operated optical key and an isolated lock that derives both its operating power and unlock signals from the correct optical key. A light emitting diode or laser diode is included within the optical key and is connected to transmit a bit-serial password. The key user physically enters either the code-to-transmit directly, or an index to a pseudorandom number code, in the key. Such person identification numbers can be retained permanently, or ephemeral. When a send button is pressed, the key transmits a beam of light modulated with the password information. The modulated beam ofmore » light is received by a corresponding optical lock with a photovoltaic cell that produces enough power from the beam of light to operate a password-screen digital logic. In one application, an acceptable password allows a two watt power laser diode to pump ignition and timing information over a fiberoptic cable into a sealed engine compartment. The receipt of a good password allows the fuel pump, spark, and starter systems to each operate. Therefore, bypassing the lock mechanism as is now routine with automobile thieves is pointless because the engine is so thoroughly disabled.« less
Hagans, Karla G.; Clough, Robert E.
2000-01-01
An optical key system comprises a battery-operated optical key and an isolated lock that derives both its operating power and unlock signals from the correct optical key. A light emitting diode or laser diode is included within the optical key and is connected to transmit a bit-serial password. The key user physically enters either the code-to-transmit directly, or an index to a pseudorandom number code, in the key. Such person identification numbers can be retained permanently, or ephemeral. When a send button is pressed, the key transmits a beam of light modulated with the password information. The modulated beam of light is received by a corresponding optical lock with a photovoltaic cell that produces enough power from the beam of light to operate a password-screen digital logic. In one application, an acceptable password allows a two watt power laser diode to pump ignition and timing information over a fiberoptic cable into a sealed engine compartment. The receipt of a good password allows the fuel pump, spark, and starter systems to each operate. Therefore, bypassing the lock mechanism as is now routine with automobile thieves is pointless because the engine is so thoroughly disabled.
Cerminara, Anthony J; LaPrade, Christopher M; Smith, Sean D; Ellman, Michael B; Wijdicks, Coen A; LaPrade, Robert F
2014-12-01
A common treatment for posterior meniscal root tears is transtibial pull-out repair, which has been biomechanically reported to restore tibiofemoral contact mechanics to those of the intact knee. Biomechanical data suggest that there is significant displacement of the repaired meniscal root with cyclic loading, which may be responsible for the poor healing and meniscal extrusion demonstrated in some clinical studies. The purpose of this study was to quantify the time-zero displacement of the posterior meniscal root in response to cyclic loading after transtibial pull-out repair and to quantify the individual contributions to displacement of the following: (1) suture elongation, (2) button-bone interface, and (3) meniscus-suture interface. The meniscus-suture interface was hypothesized to result in significantly more displacement than the button-bone interface or suture elongation. Descriptive laboratory study. Transtibial pull-out repair of the posterior medial meniscal root was performed in 6 porcine knees, and cyclic displacement was measured using a loading protocol representative of postoperative rehabilitation. Displacement from (1) suture elongation, (2) the button-bone interface, and (3) the meniscus-suture interface was determined by cyclically loading 6 specimens for each construct using the same loading protocol to determine the contribution of each component to the overall displacement of the repair construct. After 1000 cycles, the repair construct displaced by a mean of 3.28 mm (95% CI, 2.07-4.49). The meniscus-suture component (mean, 2.52 mm; 95% CI, 2.21-2.83) displaced significantly more than the button-bone component (mean, 0.90 mm; 95% CI, 0.64-1.15; P = .006) and suture elongation component (mean, 0.71 mm; 95% CI, 0.36-1.06; P = .006) after 1000 cycles. Displacement of the button-bone and suture elongation components was not significantly different after 1000 cycles (P = .720). There was substantial displacement of the posterior medial meniscal root repaired with the transtibial pull-out technique under a cyclic loading protocol simulating postoperative rehabilitation. The meniscus-suture interface contributed to significantly more displacement than the button-bone interface and suture elongation in the transtibial pull-out repair construct. The results provide a framework for optimizing the transtibial pull-out repair technique. Future studies should focus on improving suture fixation strength within the meniscus-suture interface. © 2014 The Author(s).
1986-10-31
Reference Card Given to Participants) Cognoter Reference Select = LeftButton Menu = MiddleButton TitleBar menu for tool operations Item menu for item...collaborative tools and their uses, the Colab system and the Cognoter presentation tool were implemented and used for both real and posed idea organization...tasks. To test the system design and its effect on structured problem-solving, many early Colab/ Cognoter meetings were monitored and a series of
Simpson, Tyler; Gauthier, Michel; Prochazka, Arthur
2010-02-01
Computer access can play an important role in employment and leisure activities following spinal cord injury. The authors' prior work has shown that a tooth-click detecting device, when paired with an optical head mouse, may be used by people with tetraplegia for controlling cursor movement and mouse button clicks. To compare the efficacy of tooth clicks to speech recognition and that of an optical head mouse to a gyrometer head mouse for cursor and mouse button control of a computer. Six able-bodied and 3 tetraplegic subjects used the devices listed above to produce cursor movements and mouse clicks in response to a series of prompts displayed on a computer. The time taken to move to and click on each target was recorded. The use of tooth clicks in combination with either an optical head mouse or a gyrometer head mouse can provide hands-free cursor movement and mouse button control at a speed of up to 22% of that of a standard mouse. Tooth clicks were significantly faster at generating mouse button clicks than speech recognition when paired with either type of head mouse device. Tooth-click detection performed better than speech recognition when paired with both the optical head mouse and the gyrometer head mouse. Such a system may improve computer access for people with tetraplegia.
Inclusion Behavior During the Electron Beam Button Melting Test
NASA Astrophysics Data System (ADS)
Bellot, J. P.; Defay, B.; Jourdan, J.; Chapelle, P.; Jardy, A.
2012-10-01
The high mechanical performance of alloys developed for the manufacture of turbine disks depend upon the size and the number density of the inclusions. The electron beam button method has been practiced since the 1980s as a technique to quantify the cleanliness of the superalloys as well as to identify the nature and the size of the inclusions. The technique involves melting the sample into a hemispherical water-cooled crucible and the low density inclusions (mainly oxides) are concentrated by a combination of Marangoni and buoyancy forces into an area at the top surface of the button referred to as the raft. We have experimentally studied the behavior of oxide inclusions in special steels using both high definition video and infrared cameras. We have observed the inversion of the Marangoni effect due to the presence of sulfur, which leads to a positive temperature coefficient of the surface tension. A mathematical modeling has been carried out to simulate the turbulent fluid flow associated with the temperature field in the metallic pool of the button. The surface temperature profile has been successfully compared with the measured data. A post-processor numerical tool calculates the inclusion trajectories taking into account the turbulent fluctuation velocity by a stochastic approach. Hence, the behavior of a population of inclusions has been statistically studied, and the dependence of the capture efficiency on the inclusion size has been analyzed.
Winter, Abigail; Lintner, Michaela; Knezevich, Emily
2015-04-21
Type 2 diabetes mellitus affects over 29.1 million Americans, diagnosed and undiagnosed. Achieving and maintaining glycemic control for these patients is of extreme importance when working to prevent complications and improve quality of life for patients. The V-Go is a newly developed insulin delivery system. The push of a button inserts a needle into the patient once daily and remains attached for 24 hours. The V-Go is designed to release a set basal rate throughout the day, while allowing patients to provide up to 36 units of on-demand bolus insulin with the manual click of 2 buttons. It is a spring-loaded device filled daily with rapid-acting insulin that runs without the use of batteries or computer software. The main objective of this prospective active comparator study was to observe the A1C lowering effects of multiple daily insulin injections (MDII) versus the use of the V-Go insulin delivery system for patients with uncontrolled type 2 diabetes mellitus over a 3-month period. In addition, the effect on insulin requirement for these patients was assessed with secondary comparisons of weight, blood pressure, prevalence of hypoglycemic events, and quality of life before and after 3 months of intensified insulin therapy with regular monitoring by a clinical pharmacist at an internal medicine clinic. The average A1C lowering experienced by the 3 patients in the V-Go group was 1.5%, while the average A1C change in the 3 patients in the MDII group was an increase of 0.2%. All patients in the V-Go group experienced a decrease in insulin total daily dose (TDD), with an average decrease of 26.3 units. All patients in the MDII group experienced an increase in insulin TDD with an average of 15 units daily to achieve therapeutic goals individualized for each patient. All patients who underwent intensification of insulin therapy experienced an increase in subjective quality of life (QOL) as determined using the Diabetes-39 (D-39) questionnaire, though QOL results lacked statistical significance. © 2015 Diabetes Technology Society.
Ruptured superficial dorsal vein of the penis masquerading as a penile fracture: case report.
Perlmutter, Adam E; Roberts, Lawrence; Farivar-Mohseni, Hesam; Zaslau, Stanley
2007-08-01
Acute onset of pain, swelling, and ecchymosis of the penis during sexual intercourse indicate a penile fracture until proven otherwise. However, there have been few case reports of isolated injuries to the dorsal penile artery or dorsal vein mimicking a penile fracture. Presented herein is a rare case of a patient who ruptured his superficial dorsal vein during intercourse.
Penile carcinoma presenting as inguinal bubo, masquerading as a venereal disease.
Gupta, Vishal; Rai, Ajay; Mutha, Shreyans; Firdaus Ali, Mohammad; Sharma, Vinod K
2016-03-01
We report a case of penile carcinoma presenting as an inguinal bubo in a young man. The associated painful genital ulcer and history of high-risk sexual behaviour raised a strong suspicion of a sexually transmitted infection. We review the literature for similar cases, highlight the similarities with venereal disease and discuss the differential diagnosis of inguinal bubo. © The Author(s) 2016.
Acute Legionella pneumophila infection masquerading as acute alcoholic hepatitis.
Hunter, Jonathan Michael; Chan, Julian; Reid, Angeline Louise; Tan, Chistopher
2013-01-25
A middle-aged man had deteriorated rapidly in hospital after being misdiagnosed with acute alcoholic hepatitis. Acute Legionnaires disease (Legionellosis) was subsequently diagnosed on rapid antigen urinary testing and further confirmed serologically. This led to appropriate antibiotic treatment and complete clinical resolution. Physicians caring for patients with alcohol-related liver disease should consider Legionella pneumophila in their differential diagnosis even with a paucity of respiratory symptoms.
Regunath, Hariharan; Chinnakotla, Bhavana; Rojas-Moreno, Christian; Salzer, William; Hughes, Natalie J; Sangha, Harbaksh
2016-06-01
Human rabies is a fatal disease, transmitted by saliva of infected animals, and the diagnosis requires a high index of suspicion. Very few cases are reported annually in the United States. We present a case of human rabies without a clear exposure history that masqueraded as serotonin syndrome. © The American Society of Tropical Medicine and Hygiene.
A Geant4 evaluation of the Hornyak button and two candidate detectors for the TREAT hodoscope
NASA Astrophysics Data System (ADS)
Fu, Wenkai; Ghosh, Priyarshini; Harrison, Mark J.; McGregor, Douglas S.; Roberts, Jeremy A.
2018-05-01
The performance of traditional Hornyak buttons and two proposed variants for fast-neutron hodoscope applications was evaluated using Geant4. The Hornyak button is a ZnS(Ag)-based device previously deployed at the Idaho National Laboratory's TRansient REActor Test Facility (better known as TREAT) for monitoring fast neutrons emitted during pulsing of fissile fuel samples. Past use of these devices relied on pulse-shape discrimination to reduce the significant levels of background Cherenkov radiation. Proposed are two simple designs that reduce the overall light guide mass (here, polymethyl methacrylate or PMMA), employ silicon photomultipliers (SiPMs), and can be operated using pulse-height discrimination alone to eliminate background noise to acceptable levels. Geant4 was first used to model a traditional Hornyak button, and for assumed, hodoscope-like conditions, an intrinsic efficiency of 0.35% for mono-directional fission neutrons was predicted. The predicted efficiency is in reasonably good agreement with experimental data from the literature and, hence, served to validate the physics models and approximations employed. Geant4 models were then developed to optimize the materials and geometries of two alternatives to the Hornyak button, one based on a homogeneous mixture of ZnS(Ag) and PMMA, and one based on alternating layers of ZnS(Ag) and PMMA oriented perpendicular to the incident neutron beam. For the same radiation environment, optimized, 5-cm long (along the beam path) devices of the homogeneous and layered designs were predicted to have efficiencies of approximately 1.3% and 3.3%, respectively. For longer devices, i.e., lengths larger than 25 cm, these efficiencies were shown to peak at approximately 2.2% and 5.9%, respectively. Moreover, both designs were shown to discriminate Cherenkov noise intrinsically by using an appropriate pulse-height discriminator level, i.e., pulse-shape discrimination is not needed for these devices.
Choi, Mihyun; Lee, Yong Eun; Whang, Woong-Joo; Yoo, Young-Sik; Na, Kyung-Sun; Joo, Choun-Ki
2016-03-01
To evaluate changes in intraocular pressure (IOP) in recipient and donor eyes during femtosecond laser-assisted keratoplasty (FLAK) and to assess for differences in the diameter of trephinated corneal buttons according to changes in pressure. Twenty porcine whole eyes (recipient model) and 20 porcine-corneoscleral rims (donor model) were prepared, and anterior chamber pressures were measured using a fiberoptic sensing device (Opsens, Quebec, Canada) during the femtosecond laser corneal cutting process. To determine the diameter of corneal buttons, 10 porcine whole eyes (recipient model) and 12 corneoscleral rims (donor model) of each baseline IOP were cut with the femtosecond laser programmed to the following pattern: "vertical side cut"; 1200 μm (depth), 8 mm (diameter). Digital photographs were obtained using microscopy and subsequently analyzed. The IOP (mean ± SD) for the recipient model was 10.2 (±0.9) mm Hg at baseline and ranged from 96.6 (±4.5) to ∼138.4 (±3.8) mm Hg during the corneal cutting process. This shows that the maximum IOP during FLAK increased 13.5 times compared with baseline. In the donor model, the mean pressure elevation from baseline artificial anterior chamber (AAC) pressure to corneal cutting was 15.8 (±5.4) mm Hg. This showed a positive correlation with baseline IOP [correlation coefficient (CC) = 0.827, P = 0.006]. As the baseline IOP in the recipient eye increased, trephinated corneal button size was reduced by up to 3.9% in diameter (CC = -0.945, P = 0.015). In addition, in donor eyes, the diameter was decreased by up to 11.7% as the baseline AAC pressure increased (CC = -0.934, P = 0.006). During the FLAK procedure, the IOP increases in both recipient and donor eyes. The diameter of the trephinated donor and recipient corneal buttons was decreased as the initial baseline IOP increased. Ophthalmic surgeons can determine the AAC pressure based on the baseline IOP in the recipient patient.
A Geant4 evaluation of the Hornyak button and two candidate detectors for the TREAT hodoscope
Fu, Wenkai; Ghosh, Priyarshini; Harrison, Mark; ...
2018-02-05
The performance of traditional Hornyak buttons and two proposed variants for fast-neutron hodoscope applications was evaluated using Geant4. The Hornyak button is a ZnS(Ag)-based device previously deployed at the Idaho National Laboratory's TRansient REActor Test Facility (better known as TREAT) for monitoring fast neutrons emitted during pulsing of fissile fuel samples. Past use of these devices relied on pulse-shape discrimination to reduce the significant levels of background Cherenkov radiation. Proposed are two simple designs that reduce the overall light guide mass (here, polymethyl methacrylate or PMMA), employ silicon photomultipliers (SiPMs), and can be operated using pulse-height discrimination alone to eliminatemore » background noise to acceptable levels. Geant4 was first used to model a traditional Hornyak button, and for assumed, hodoscope-like conditions, an intrinsic efficiency of 0.35% for mono-directional fission neutrons was predicted. The predicted efficiency is in reasonably good agreement with experimental data from the literature and, hence, served to validate the physics models and approximations employed. Geant4 models were then developed to optimize the materials and geometries of two alternatives to the Hornyak button, one based on a homogeneous mixture of ZnS(Ag) and PMMA, and one based on alternating layers of ZnS(Ag) and PMMA oriented perpendicular to the incident neutron beam. For the same radiation environment, optimized, 5-cm long (along the beam path) devices of the homogeneous and layered designs were predicted to have efficiencies of approximately 1.3% and 3.3%, respectively. For longer devices, i.e., lengths larger than 25 cm, these efficiencies were shown to peak at approximately 2.2% and 5.9%, respectively. Furthermore, both designs were shown to discriminate Cherenkov noise intrinsically by using an appropriate pulse-height discriminator level, i.e., pulse-shape discrimination is not needed for these devices.« less
Revision ulnar collateral ligament reconstruction using a suspension button fixation technique.
Lee, Gregory H; Limpisvasti, Orr; Park, Maxwell C; McGarry, Michelle H; Yocum, Lewis A; Lee, Thay Q
2010-03-01
Revision ulnar collateral ligament reconstruction remains a challenging problem. The objective of this study was to biomechanically evaluate an ulnar collateral ligament reconstruction technique using a suspension button fixation technique that can be used even in the case of ulnar cortical bone loss. An ulnar suspension fixation technique for ulnar collateral ligament reconstruction can restore elbow kinematics and demonstrate failure strength comparable to that of currently available techniques. Controlled laboratory study. Nine pairs of cadaveric elbows were dissected free of soft tissue and potted. After simulating ulnar cortical bone loss, ulnar collateral ligament reconstruction was performed in 1 elbow of each pair using palmaris longus autograft and a 30-mm RetroButton suspended from the far (lateralmost) ulnar cortex. A docking technique was used for humeral fixation of the graft. Elbow valgus angle was quantified using a Microscribe 3DLX digitizer at multiple elbow flexion angles. Valgus angle was measured with the ulnar collateral ligament intact, transected, and reconstructed. In addition, load-to-failure testing was performed in 1 elbow of each pair. Release of the ulnar collateral ligament caused a significant increase in valgus angle at each flexion angle tested (P < .002). Reconstructed elbows demonstrated no significant differences in valgus angle from the intact elbow at all flexion angles tested. Load-to-failure tests showed that reconstructed elbows had an ultimate torque (10.3 + or - 5.7 N x m) significantly less than intact elbows (26.4 + or - 10.6 N x m) (P = .001). Ulnar collateral ligament reconstruction using a suspension button fixation technique reliably restored elbow kinematics to the intact state. Load-to-failure testing demonstrated comparable fixation strength to several historic controls of primary reconstruction techniques despite the simulated ulnar cortical bone loss. Ulnar collateral ligament reconstruction using a suspension button fixation technique can be considered in the case of ulnar cortical bone loss in a primary or revision setting.
Issa, S-P; Payan, C; Le Hanneur, M; Loriaut, P; Boyer, P
2018-02-01
Double-button devices for endoscopic management of acute acromioclavicular joint dislocation (ACJD) provide satisfactory short-term functional and radiological results. However, little exists in the literature regarding the long- and medium-term results of these implants, especially regarding the evolution of the acromioclavicular joint (ACJ). Satisfactory and steady long- and medium-term outcomes can be achieved in patients with acute ACJD undergoing endoscopically assisted ACJ repair using a single double-button device. A retrospective single-center study was conducted in patients with acute Rockwood III and IV ACJD treated endoscopically with a single double-button device from October 2008 to October 2010, allowing a minimum 5-year follow-up. Functional evaluation used Constant and Quick-DASH scores. Clinical evidence of dislocation recurrence was combined with bilateral Zanca views to assess coracoclavicular distance. Acromioclavicular osteoarthritis was evaluated on the Paxinos test and Zanca views. Nineteen of the 25 operated patients were seen at a mean 76.9±8.5 months' follow-up. Mean age was 34.4±8.3 years. Mean Constant and Quick-DASH scores were 96.2±5.1 and 0.9±1.6 points, respectively. Four patients had a recurrence of their initial dislocation, 3 of whom had positive Paxinos test, whereas the 15 patients without recurrence had a negative test (p=0.004). Five patients had radiological evidence of ACJ osteoarthritis: all 4 patients with recurrence and 1 without (p=0.001). Long- and medium-term radioclinical outcome of endoscopically assisted management of acute ACJD using a single double-button device seems to be satisfactory and steady over time. Recurrence of the initial dislocation appears to be related to onset of degenerative ACJ arthropathy. Therapeutic type IV-Retrospective case series. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Investigation of Optically Induced Avalanching in GaAs
1989-06-01
by Bovino , et al 4 to increase the hold off voltage. The button switch design of Fig. 4c has been used by several researchers5 ’ 7 to obtain the...ul Long flashover palh Figure 3b. 434 Optical Jlatlern a. Mourou Switch b. Bovino Switch c. Button Switch Figure 4. Photoconductive Switches...Technology and Devices Laboratory, ERADCOM (by L. Bovino , et. all) 4 • The deposition recipe for the contacts is 1) 50 ANi (provides contact to GaAs
Design and Implementation of an Operations Module for the ARGOS paperless Ship System
1989-06-01
A. OPERATIONS STACK SCRIPTS SCRIPTS FOR STACK: operations * BACKGROUND #1: Operations * on openStack hide message box show menuBar pass openStack end... openStack ** CARD #1, BUTTON #1: Up ***** on mouseUp visual effect zoom out go to card id 10931 of stack argos end mouseUp ** CARD #1, BUTTON #2...STACK SCRIPTS SCRIPTS FOR STACK: Reports ** BACKGROUND #1: Operations * on openStack hie message box show menuBar pass openStack end openStack ** CARD #1
Sealing Penetrating Eye Injuries Using Photoactivated Bonding
2010-09-30
on corneal tissue. To evaluate inflammation all 15 rabbits will be euthanized with phenobarbital . The 10 corneoscleral button of tissue will be...will be euthanized with phenobarbital . The corneoscleral button of tissue will be removed and divided into portions for paraffin and frozen sections
1976-10-01
should he made for either ixiternal storage or a means of voiding the urinal in a storage container in the compartment’. Development of-Adequate...upper temperature ranges fu- critical components of the M60 tank under desert storage and operational conditions. He found that the Wet Bulb Globe...five-gallon cans on the outside turret bustle racks. If buttoned-up operations for extended periods of time are envisioned, a built-in water storage
Energy Saving in Electric Lighting for the United States Army.
1979-10-05
these reasons. Avoid devices such as power saving buttons which are to be placed in the sockets of incandescent bulbs. They are merely half-wave...using the button or a long-life bulb. Another device to avoid is the pulse or transient suppressor. This device, essentially a voltage clipper...arranged In a geo- metric pattern. It is used to shield a lamp from Lumen: A unit of light output from a lamp. view at certain angles to avoid glare from
Far Forward Life Support System (FFLSS) Phase II
2001-05-01
button will clear audible, flashing , or constant red alarms. Pushing the Config button drops down to the Level 2 menu (bottom line of Figure 8). In...disabled. Again, with testing this audible noise can be disabled. The visual flashing or constant red cannot be disabled. Pushing Return goes back to Level...Calling PLOTPIXEL( x ,y) and PLOTLINE(xl,x2,yl,y2) is as simple as pushing the appropriate bytes (unsigned integers) onto the stack and jumping to the
The structure of affective action representations: temporal binding of affective response codes.
Eder, Andreas B; Müsseler, Jochen; Hommel, Bernhard
2012-01-01
Two experiments examined the hypothesis that preparing an action with a specific affective connotation involves the binding of this action to an affective code reflecting this connotation. This integration into an action plan should lead to a temporary occupation of the affective code, which should impair the concurrent representation of affectively congruent events, such as the planning of another action with the same valence. This hypothesis was tested with a dual-task setup that required a speeded choice between approach- and avoidance-type lever movements after having planned and before having executed an evaluative button press. In line with the code-occupation hypothesis, slower lever movements were observed when the lever movement was affectively compatible with the prepared evaluative button press than when the two actions were affectively incompatible. Lever movements related to approach and avoidance and evaluative button presses thus seem to share a code that represents affective meaning. A model of affective action control that is based on the theory of event coding is discussed.
Investigation of He-W interactions using DiMES on DIII-D
NASA Astrophysics Data System (ADS)
Doerner, R. P.; Rudakov, D. L.; Chrobak, C. P.; Briesemeister, A. R.; Corr, C.; De Temmerman, G.; Kluth, P.; Lasnier, C. J.; McLean, A. G.; Pace, D. C.; Pitts, R. A.; Schmitz, O.; Thompson, M.; Winters, V.
2016-02-01
Tungsten button samples were exposed to He ELMing H-mode plasma in DIII-D using 2.3 MW of electron cyclotron heating power. Prior to the exposures, the W buttons were exposed to either He, or D, plasma in PISCES-A for 2000 s at surface temperatures of 225-850 °C to create a variety of surfaces (surface blisters, subsurface nano-bubbles, fuzz). Erosion was spectroscopically measured from each DiMES sample, with the exception of the fuzzy W samples which showed almost undetectable WI emission. Post-exposure grazing incidence small angle x-ray scattering surface analysis showed the formation of 1.5 nm diameter He bubbles in the surface of W buttons after only a single DIII-D (3 s, ˜150 ELMs) discharge, similar to the bubble layer resulting from the 2000 s. exposure in PISCES-A. No surface roughening, or damage, was detected on the samples after approximately 600 ELMs with energy density between 0.04-0.1 MJ m-2.
eButton: A Wearable Computer for Health Monitoring and Personal Assistance
Sun, Mingui; Burke, Lora E.; Mao, Zhi-Hong; Chen, Yiran; Chen, Hsin-Chen; Bai, Yicheng; Li, Yuecheng; Li, Chengliu; Jia, Wenyan
2014-01-01
Recent advances in mobile devices have made profound changes in people's daily lives. In particular, the impact of easy access of information by the smartphone has been tremendous. However, the impact of mobile devices on healthcare has been limited. Diagnosis and treatment of diseases are still initiated by occurrences of symptoms, and technologies and devices that emphasize on disease prevention and early detection outside hospitals are under-developed. Besides healthcare, mobile devices have not yet been designed to fully benefit people with special needs, such as the elderly and those suffering from certain disabilities, such blindness. In this paper, an overview of our research on a new wearable computer called eButton is presented. The concepts of its design and electronic implementation are described. Several applications of the eButton are described, including evaluating diet and physical activity, studying sedentary behavior, assisting the blind and visually impaired people, and monitoring older adults suffering from dementia. PMID:25340176
A novel wearable smart button system for fall detection
NASA Astrophysics Data System (ADS)
Zhuang, Wei; Sun, Xiang; Zhi, Yueyan; Han, Yue; Mao, Hande
2017-05-01
Fall has been the second most cause of accidental injury to death in the world. It has been a serious threat to the physical and mental health of the elders. Therefore, developing wearable node system with fall detecting ability has become increasingly pressing at present. A novel smart button for long-term fall detection is proposed in this paper, which is able to accurately monitor the falling behavior, and sending warning message online as well. The smart button is based on the tri-axis acceleration sensor which is used to collect the body motion signals. By using the statistical metrics of acceleration characteristics, a new SVM classification algorithm with high positive accuracy and stability is proposed so as to classify the falls and activities of daily living, and the results can be real-time displayed on Android based mobile phone. The experiments show that our wearable node system can continuously monitor the falling behavior with positive rate 94.8%.
Field evaluation of personal sampling methods for multiple bioaerosols.
Wang, Chi-Hsun; Chen, Bean T; Han, Bor-Cheng; Liu, Andrew Chi-Yeu; Hung, Po-Chen; Chen, Chih-Yong; Chao, Hsing Jasmine
2015-01-01
Ambient bioaerosols are ubiquitous in the daily environment and can affect health in various ways. However, few studies have been conducted to comprehensively evaluate personal bioaerosol exposure in occupational and indoor environments because of the complex composition of bioaerosols and the lack of standardized sampling/analysis methods. We conducted a study to determine the most efficient collection/analysis method for the personal exposure assessment of multiple bioaerosols. The sampling efficiencies of three filters and four samplers were compared. According to our results, polycarbonate (PC) filters had the highest relative efficiency, particularly for bacteria. Side-by-side sampling was conducted to evaluate the three filter samplers (with PC filters) and the NIOSH Personal Bioaerosol Cyclone Sampler. According to the results, the Button Aerosol Sampler and the IOM Inhalable Dust Sampler had the highest relative efficiencies for fungi and bacteria, followed by the NIOSH sampler. Personal sampling was performed in a pig farm to assess occupational bioaerosol exposure and to evaluate the sampling/analysis methods. The Button and IOM samplers yielded a similar performance for personal bioaerosol sampling at the pig farm. However, the Button sampler is more likely to be clogged at high airborne dust concentrations because of its higher flow rate (4 L/min). Therefore, the IOM sampler is a more appropriate choice for performing personal sampling in environments with high dust levels. In summary, the Button and IOM samplers with PC filters are efficient sampling/analysis methods for the personal exposure assessment of multiple bioaerosols.
Beam Diagnostics of the Compton Scattering Chamber in Jefferson Lab's Hall C
NASA Astrophysics Data System (ADS)
Faulkner, Adam; I&C Group Collaboration
2013-10-01
Upcoming experimental runs in Hall C will utilize Compton scattering, involving the construction and installation of a rectangular beam enclosure. Conventional cylindrical stripline-style Beam Position Monitors (BPMs) are not appropriate due to their form factor; therefore to facilitate measurement of position, button-style BPMs are being considered due to the ease of placement within the new beam enclosure. Button BPM experience is limited at JLAB, so preliminary measurements are needed to characterize the field response, and guide the development of appropriate algorithms for the Analog to Digital receiver systems. -field mapping is performed using a Goubau Line (G-Line), which employs a surface wave to mimic the electron beam, helping to avoid problems associated with vacuum systems. Potential algorithms include simplistic 1/r modeling (-field mapping), look-up-tables, as well as a potential third order power series fit. In addition, the use of neural networks specifically the multi-layer Perceptron will be examined. The models, sensor field maps, and utility of the neural network will be presented. Next steps include: modification of the control algorithm, as well as to run an in-situ test of the four Button electrodes inside of a mock beam enclosure. The analysis of the field response using Matlab suggests the button BPMs are accurate to within 10 mm, and may be successful for beam diagnostics in Hall C. More testing is necessary to ascertain the limitations of the new electrodes. The National Science Foundation, Old Dominion University, The Department of Energy, and Jefferson Lab.
A Computational Approach to the Quantification of Animal Camouflage
2014-06-01
radiometry and photometry. McGraw-Hill, Inc., Boggs CL, Watt WB, Ehrlich PR (2003) Butterflies: ecology and evolution taking flight. University of...Rowland HM, Ruxton GD (2010) The evolution and ecology of masquerade. Biological Journal of the Linnean Society 99:1-8 Skelhorn J, Ruxton GD (2011...applications have previously been explored, albeit disjointly, in ecology (Levin et al. 2005), environmental sciences (De La Barrera and Smith 2009
Aortic intimal sarcoma masquerading as bilateral renal artery stenosis.
Sethi, Supreet; Pothineni, Naga Krishna; Syal, Gaurav; Ali, Syed Mujtaba; Krause, Michelle W
2013-01-01
Aortic intimal sarcoma is a rare tumor with poor prognosis. The most common manifestations are thromboembolic phenomena and vascular obstruction. We present a case of aortic intimal sarcoma causing bilateral renal artery stenosis which manifested as resistant hypertension and acute kidney inury. Multiple attempts to stent the renal arteries were unsuccessful. Eventually the patient developed acute limb ischemia and oliguric kidney failure as complications of the primary tumor.
Acute Legionella pneumophila infection masquerading as acute alcoholic hepatitis
Hunter, Jonathan Michael; Chan, Julian; Reid, Angeline Louise; Tan, Chistopher
2013-01-01
A middle-aged man had deteriorated rapidly in hospital after being misdiagnosed with acute alcoholic hepatitis. Acute Legionnaires disease (Legionellosis) was subsequently diagnosed on rapid antigen urinary testing and further confirmed serologically. This led to appropriate antibiotic treatment and complete clinical resolution. Physicians caring for patients with alcohol-related liver disease should consider Legionella pneumophila in their differential diagnosis even with a paucity of respiratory symptoms. PMID:23355576
Congenital esophageal stenosis: the differential diagnosis and management.
Jones, Douglas W; Kunisaki, Shaun M; Teitelbaum, Daniel H; Spigland, Nitsana A; Coran, Arnold G
2010-05-01
Congenital esophageal stenosis (CES) is a rare congenital abnormality that is difficult to diagnose and often masquerades as other types of structural esophageal disease. We report three cases of CES with different presenting symptoms. We advocate for balloon dilation as the preferred first approach to therapeutic intervention. CES is an important clinical entity in the evaluation of pediatric esophageal disorders and should be suspected in young infants with dysphagia.
Focal cemento-osseous dysplasia masquerading as benign cementoblastoma: A diagnostic dilemma.
Rao, Gayathri S; Kamalapur, Muralidhar G; Acharya, Swetha
2014-01-01
Focal cemento-osseous dysplasia (FCOD) is a fibro-osseous lesion that is a nonneoplastic reactive lesion. A case of 47-year-old female patient presenting with a diagnostic dilemma to the clinician is reported. Methods to achieve definitive diagnosis are discussed. FCOD can present with features of periapical pathology or other osseous lesions. Hence, to arrive at a definitive diagnosis biopsy and histopathologic examination is imperative.
Masquerade Detection Using a Taxonomy-Based Multinomial Modeling Approach in UNIX Systems
2008-08-25
primarily the modeling of statistical features , such as the frequency of events, the duration of events, the co- occurrence of multiple events...are identified, we can extract features representing such behavior while auditing the user’s behavior. Figure1: Taxonomy of Linux and Unix...achieved when the features are extracted just from simple commands. Method Hit Rate False Positive Rate ocSVM using simple cmds (freq.-based
Dedifferentiated Liposarcoma Masquerading as Rhabdomyosarcoma.
Kobayashi, Anna; Hirose, Takanori; Kudo, Eiji; Kawashita, Youichiro; Yagi, Toshiyuki
We present a rare case of retroperitoneal dedifferentiated liposarcoma (DDLPS) masquerading as rhabdomyosarcoma. The patient was a 74-year-old man, complaining a loss of appetite. Abdominal computed tomography revealed a retroperitoneal mass, 10 cm in diameter, between the liver and the right adrenal gland. The tumor was resected and histologically diagnosed as conventional DDLPS, in which dedifferentiated component was highly cellular and composed of pleomorphic anaplastic cells. After 3 years, the tumor recurred in the right retroperitoneal space. The recurrent tumor consisted of 2 components: lipogenic and nonlipogenic. The latter differ from the dedifferentiated component of the primary tumor. The tumor cells were small, round to ovoid cells with monomorphous, round, hyperchromatic nuclei, and scant cytoplasm. Interestingly, they were diffusely positive for myogenin and desmin. To rule out the possibility of the second primary, we performed fluorescence in situ hybridization to detect FOXO1 rearrangement. We failed to demonstrate splits of the probes. In contrast, high-level amplification of MDM2 was detected by dual-color in situ hybridization. Given the morphologic and molecular findings, the neoplasm was identified as a peculiar DDLPS mimicking rhabdomyosarcoma. Retroperitoneal rhabdomyosarcoma-like tumors of adults, therefore, should be distinguished carefully from DDLPS. It could be challenging when lipogenic component was absent, but in situ molecular analyses can be helpful.
Drain Tube-Induced Jejunal Penetration Masquerading as Bile Leak following Whipple's Operation.
Bae, Sang Ho; Lee, Tae Hoon; Lee, Sae Hwan; Lee, Suck-Ho; Park, Sang-Heum; Kim, Sun-Joo; Kim, Chang Ho
2011-05-01
A 70-year-old man had undergone pancreaticoduodenectomy due to a distal common bile duct malignancy. After the operation, serous fluid discharge decreased from two drain tubes in the retroperitoneum. Over four weeks, the appearance of the serous fluid changed to a greenish bile color and the patient persistently drained over 300 ml/day. Viewed as bile leak at the choledochojejunostomy, treatment called for endoscopic diagnosis and therapy. Cap-fitted forward-viewing endoscopy demonstrated that the distal tip of a pancreatic drain catheter inserted at the pancreaticojejunostomy site had penetrated the opposite jejunum wall. One of the drain tubes primarily placed in the retroperitoneum had also penetrated the jejunum wall, with the distal tip positioned near the choledochojejunostomy site. No leak of contrast appeared beyond the jejunum or anastomosis site. Following repositioning of a penetrating catheter of the pancreaticojejunostomy, four days later, the patient underwent removal of two drain tubes without additional complications. In conclusion, the distal tip of the catheter, placed to drain pancreatic juice, penetrated the jejunum wall and may have caused localized perijejunal inflammation. The other drain tube, placed in the retroperitoneal space, might then have penetrated the inflamed wall of the jejunum, allowing persistent bile drainage via the drain tube. The results masqueraded as bile leakage following pancreaticoduodenectomy.
Re-Engineering the United States Marine Corps’ Enlisted Assignment Model (EAM)
1998-06-01
and Execution button opens the switchboard in Figure 12. This form accesses all of the VBA code that is associated with this form and the code that...the prototype to prompt the user and to inform him of what he is about to do. Each of the buttons that are on these forms is connected to an SQL ...into the field for building a rule are the values 2;3;4;5;6;7. The user can enter an SQL statement that would determine the values or the user could
2012-03-05
Alarm button. Under the GPS frame are two smaller frames. On the left is a frame with buttons labeled Tractor Guidance and Acquisition Error... GPS ) and the Attitude Heading Reference System (AHRS) data. 5.2 Using the Data Acquisition Simulator Software The simulator and a practice set... acquisition for one polarity of the TX (33ms dead band for relay switching + 33 ms of waveforms). When the GPS is being used this is usually “1”, but may be
Refractory seizures due to a dural-based cavernoma masquerading as a meningioma.
Zeng, Xianwei; Mahta, Ali; Kim, Ryan Y; Saad, Ali G; Kesari, Santosh
2012-04-01
A 37-year-old female presented with medically intractable complex partial seizures with secondary generalization. She was found to have a dural-based lesion with radiologic features of meningioma. A gross total resection was performed and pathology confirmed a diagnosis of cavernous angioma and she became seizure free after the surgical resection. Cavernous angioma should be considered in differential diagnosis of a dural-based lesion manifesting with refractory seizures.
Staging gender and sexuality in experimental TV entertainment.
Mühleisen, Wencke
2008-01-01
Via examples from recent Norwegian experimental TV shows, this article explores the function of "eye-catchers," parodic (hetero)sexualization, female masquerade and neo-masculinization as strategies for "repetitions with a difference" of traditional styles and motifs by female show hosts, as well as the queer gendering and sexualization of men and masculinities by their male counterparts. Both formats represent innovative renegotiations of gender and sexuality that illustrate the relationship between post-modernism and queer aesthetics.
Localized amyloidosis masquerading as nasopharyngeal tumor: a review.
Panda, Naresh K; Saravanan, Karuppiah; Purushotaman, Gilbert Pragache; Gurunathan, Ramesh Kumar; Mahesha, Vankalakunti
2007-01-01
Amyloidosis comprises a diverse collection of disease characterized by the presence of amorphous extracellular eosinophilic deposits of unique protein fibrils that gives apple green birefringence under polarized light after staining with Congo red. Head and neck region is the commonest site for localized form of amyloidosis. We report a case of a 43-year-old man with localized amyloidosis of nasopharynx with oropharyngeal extension and its management, along with a review of relevant literatures.
Focal cemento-osseous dysplasia masquerading as benign cementoblastoma: A diagnostic dilemma
Rao, Gayathri S; Kamalapur, Muralidhar G; Acharya, Swetha
2014-01-01
Context: Focal cemento-osseous dysplasia (FCOD) is a fibro-osseous lesion that is a nonneoplastic reactive lesion. Case Report: A case of 47-year-old female patient presenting with a diagnostic dilemma to the clinician is reported. Methods to achieve definitive diagnosis are discussed. Conclusions: FCOD can present with features of periapical pathology or other osseous lesions. Hence, to arrive at a definitive diagnosis biopsy and histopathologic examination is imperative. PMID:24959061
More than meets the eye: infant presenting with hypoxic ischaemic encephalopathy.
Sen, Kuntal; Agarwal, Rajkumar
2018-04-05
We report a newborn infant who presented with poor Apgar scores and umbilical artery acidosis leading to the diagnosis of hypoxic ischaemic encephalopathy. During the course of the infant's hospitalisation, subsequent workup revealed an underlying genetic cause that masqueraded as hypoxic ischaemic encephalopathy. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
A wireless narrowband imaging chip for capsule endoscope.
Lan-Rong Dung; Yin-Yi Wu
2010-12-01
This paper presents a dual-mode capsule gastrointestinal endoscope device. An endoscope combined with a narrowband image (NBI), has been shown to be a superior diagnostic tool for early stage tissue neoplasms detection. Nevertheless, a wireless capsule endoscope with the narrowband imaging technology has not been presented in the market up to now. The narrowband image acquisition and power dissipation reduction are the main challenges of NBI capsule endoscope. In this paper, we present the first narrowband imaging capsule endoscope that can assist clinical doctors to effectively diagnose early gastrointestinal cancers, profited from our dedicated dual-mode complementary metal-oxide semiconductor (CMOS) sensor. The dedicated dual-mode CMOS sensor can offer white-light and narrowband images. Implementation results show that the proposed 512 × 512 CMOS sensor consumes only 2 mA at a 3-V power supply. The average current of the NBI capsule with an 8-Mb/s RF transmitter is nearly 7 ~ 8 mA that can continuously work for 6 ~ 8 h with two 1.5-V 80-mAh button batteries while the frame rate is 2 fps. Experimental results on backside mucosa of a human tongue and pig's small intestine showed that the wireless NBI capsule endoscope can significantly improve the image quality, compared with a commercial-of-the-shelf capsule endoscope for gastrointestinal tract diagnosis.
Transient human auditory cortex activation during volitional attention shifting
Uhlig, Christian Harm; Gutschalk, Alexander
2017-01-01
While strong activation of auditory cortex is generally found for exogenous orienting of attention, endogenous, intra-modal shifting of auditory attention has not yet been demonstrated to evoke transient activation of the auditory cortex. Here, we used fMRI to test if endogenous shifting of attention is also associated with transient activation of the auditory cortex. In contrast to previous studies, attention shifts were completely self-initiated and not cued by transient auditory or visual stimuli. Stimuli were two dichotic, continuous streams of tones, whose perceptual grouping was not ambiguous. Participants were instructed to continuously focus on one of the streams and switch between the two after a while, indicating the time and direction of each attentional shift by pressing one of two response buttons. The BOLD response around the time of the button presses revealed robust activation of the auditory cortex, along with activation of a distributed task network. To test if the transient auditory cortex activation was specifically related to auditory orienting, a self-paced motor task was added, where participants were instructed to ignore the auditory stimulation while they pressed the response buttons in alternation and at a similar pace. Results showed that attentional orienting produced stronger activity in auditory cortex, but auditory cortex activation was also observed for button presses without focused attention to the auditory stimulus. The response related to attention shifting was stronger contralateral to the side where attention was shifted to. Contralateral-dominant activation was also observed in dorsal parietal cortex areas, confirming previous observations for auditory attention shifting in studies that used auditory cues. PMID:28273110
Zacour, Brian M; Pandey, Preetanshu; Subramanian, Ganeshkumar; Gao, Julia Z; Nikfar, Faranak
2014-06-01
The objective of this study was to determine the impact that the micro-environment, as measured by PyroButton data loggers, experienced by tablets during the pan coating unit operation had on the layer adhesion of bilayer tablets in open storage conditions. A full factorial design of experiments (DOE) with three center points was conducted to study the impact of final tablet hardness, film coating spray rate and film coating exhaust temperature on the delamination tendencies of bilayer tablets. PyroButton data loggers were placed (fixed) at various locations in a pan coater and were also allowed to freely move with the tablet bed to measure the micro-environmental temperature and humidity conditions of the tablet bed. The variance in the measured micro-environment via PyroButton data loggers accounted for 75% of the variance in the delamination tendencies of bilayer tablets on storage (R(2 )= 0.75). A survival analysis suggested that tablet hardness and coating spray rate significantly impacted the delamination tendencies of the bilayer tablets under open storage conditions. The coating exhaust temperature did not show good correlation with the tablets' propensity to crack indicating that it was not representative of the coating micro-environment. Models created using data obtained from the PyroButton data loggers outperformed models created using primary DOE factors in the prediction of bilayer tablet strength, especially upon equipment or scale transfers. The coating micro-environment experienced by tablets during the pan coating unit operation significantly impacts the strength of the bilayer interface of tablets on storage.
Dedeoğlu, Süleyman Semih; İmren, Yunus; Çabuk, Haluk; Çakar, Murat; Arslan, Samet Murat; Esenyel, Cem Zeki
2017-01-01
We aimed to evaluate clinical and functional outcomes of indirect fracture reduction performed by coracoclavicular fixation with minimal invasive double button lift-up system in Neer type IIa unstable fractures of distal clavicle. 22 patients with Neer type 2 distal clavicle fracture were enrolled in that prospective study. All patients underwent indirect reduction and osteosynthesis performed by coracoclavicular fixation with minimal invasive double button lift-up system. Postoperative follow-up was carried out clinically and radiologically with plain X-rays and utilization of Constant and American Shoulder and Elbow Surgeons Standardized Shoulder Assessment (ASES) shoulder scores. Mean follow-up time was 15 months. A standard sling was applied for 2 weeks, postoperatively. Rehabilitation program was started on postoperative day 1. Mean age was 39 (range: 21-60), 18 of the patients were male. Right dominant extremity was affected in 14 patients. Mean duration of the surgical intervention was 40 min (range: 30-55 min). Mean union time was found to be 14 weeks (range: 7-21 weeks). Mean postoperative ASES and Constant scores were 79.9 (66.9-88.3) and 82.2 (71-100), respectively. The duration of return to normal daily activities were found to be 4.5 months. Any loss of reduction, AC joint arthrosis, and clavicular shortening were not detected in X-rays. This study has demonstrated that indirect osteosynthesis performed by coracoclavicular fixation with double button lift-up system in the treatment of unstable Neer type IIa fractures of the distal clavicle had successful clinical, radiological, and functional outcomes.
NASA Astrophysics Data System (ADS)
Osada, Masakazu; Kaise, Mitsuru; Ozeki, Takeshi; Tsunakawa, Hirofumi; Tsunakawa, Kiyoshi; Takayanagi, Takashi; Suzuki, Nobuaki; Miwa, Jun; Ohta, Yasuhiko; Kanai, Koichi
1999-07-01
We have proposed a new user interface with workflow customization, implemented and evaluted in Endoscopy Department Mini-PACS that has been introduced and routinely used for two years at Toshiba General Hospital. We have set some task at endoscopy image acquisition units during examinations for two different types of user interfaces and compared performance. One is a command-button based operation using a remote control, and another is that with eight graphic buttons which are displayed on a CRT monitor and can be customized. Results of the two-year study show that mean number of input diagnosis codes per examination with graphic and customized interface is significantly greater than that with conventional interface. Also, mean time to complete one upper gastric endoscopy examination with new user interface is about 17 percent less than that with conventional interface. These result suggest that systems with the visualized and customized operation and feedback encourages physicians to use more functions and to compete tasks more efficiently than systems with conventional command-button based user interfaces.
Concepts for multi-IFU robotic positioning systems
NASA Astrophysics Data System (ADS)
Miziarski, Stan; Brzeski, Jurek; Bland Hawthorn, Joss; Gilbert, James; Goodwin, Michael; Heijmans, Jeroen; Horton, Anthony; Lawrence, Jon; Saunders, Will; Smith, Greg A.; Staszak, Nicholas
2012-09-01
Following the successful commissioning of SAMI (Sydney-AAO Multi-object IFU) the AAO has undertaken concept studies leading to a design of a new instrument for the AAT (Hector). It will use an automated robotic system for the deployment of fibre hexabundles to the focal plane. We have analysed several concepts, which could be applied in the design of new instruments or as a retrofit to existing positioning systems. We look at derivatives of Starbugs that could handle a large fibre bundle as well as modifications to pick and place robots like 2dF or OzPoz. One concept uses large magnetic buttons that adhere to a steel field plate with substantial force. To move them we replace the gripper with a pneumatic device, which engages with the button and injects it with compressed air, thus forming a magnet preloaded air bearing allowing virtually friction-less repositioning of the button by a gantry or an R-Theta robot. New fibre protection, guiding and retraction systems are also described. These developments could open a practical avenue for the upgrade to a number of instruments.
Early event-related brain potentials that reflect interest for content information in the media.
Adachi, Shinobu; Morikawa, Koji; Nittono, Hiroshi
2012-03-28
This study investigated the relationship between event-related brain potentials (ERPs) to abridged content information in the media and the subsequent decisions to view the full content. Student volunteers participated in a task that simulated information selection on the basis of the content information. Screenshots of television clips and headlines of news articles on the Web were used as content information for the image condition and the headline condition, respectively. Following presentation of a stimulus containing content information, participants decided whether or not they would view the full content by pressing a select or a reject button. When the select button was pressed, participants were presented with a television clip or a news article. When the reject button was pressed, participants continued on to the next trial, without viewing further. In comparison with rejected stimuli, selected stimuli elicited a larger negative component, with a peak latency of ∼250 ms. The increase in the negative component was independent of the type of visual stimulus. These results suggest that interest toward content information is reflected in early-stage event-related brain potential responses.
Investigation of He–W interactions using DiMES on DIII-D
DOE Office of Scientific and Technical Information (OSTI.GOV)
Doerner, R. P.; Rudakov, D. L.; Chrobak, C. P.
Here, tungsten button samples were exposed to He ELMing H-mode plasma in DIII-D using 2.3 MW of electron cyclotron heating power. Prior to the exposures, the W buttons were exposed to either He, or D, plasma in PISCES-A for 2000 s at surface temperatures of 225–850 °C to create a variety of surfaces (surface blisters, subsurface nano-bubbles, fuzz). Erosion was spectroscopically measured from each DiMES sample, with the exception of the fuzzy W samples which showed almost undetectable WI emission. Post-exposure grazing incidence small angle x-ray scattering surface analysis showed the formation of 1.5 nm diameter He bubbles in themore » surface of W buttons after only a single DIII-D (3 s, ~150 ELMs) discharge, similar to the bubble layer resulting from the 2000 s. exposure in PISCES-A. No surface roughening, or damage, was detected on the samples after approximately 600 ELMs with energy density between 0.04–0.1 MJ m –2.« less
Investigation of He–W interactions using DiMES on DIII-D
Doerner, R. P.; Rudakov, D. L.; Chrobak, C. P.; ...
2016-01-22
Here, tungsten button samples were exposed to He ELMing H-mode plasma in DIII-D using 2.3 MW of electron cyclotron heating power. Prior to the exposures, the W buttons were exposed to either He, or D, plasma in PISCES-A for 2000 s at surface temperatures of 225–850 °C to create a variety of surfaces (surface blisters, subsurface nano-bubbles, fuzz). Erosion was spectroscopically measured from each DiMES sample, with the exception of the fuzzy W samples which showed almost undetectable WI emission. Post-exposure grazing incidence small angle x-ray scattering surface analysis showed the formation of 1.5 nm diameter He bubbles in themore » surface of W buttons after only a single DIII-D (3 s, ~150 ELMs) discharge, similar to the bubble layer resulting from the 2000 s. exposure in PISCES-A. No surface roughening, or damage, was detected on the samples after approximately 600 ELMs with energy density between 0.04–0.1 MJ m –2.« less
Richard, Raveesh Daniel; Bowen, Thomas R
2017-07-01
Contaminated operating room surfaces can increase the risk of orthopaedic infections, particularly after procedures in which hardware implantation and instrumentation are used. The question arises as to how surgeons can measure surface cleanliness to detect increased levels of bioburden. This study aims to highlight the utility of adenosine triphosphate (ATP) bioluminescence technology as a novel technique in detecting the degree of contamination within the sterile operating room environment. What orthopaedic operating room surfaces are contaminated with bioburden? When energy is required for cellular work, ATP breaks down into adenosine biphosphate (ADP) and phosphate (P) and in that process releases energy. This process is inherent to all living things and can be detected as light emission with the use of bioluminescence assays. On a given day, six different orthopaedic surgery operating rooms (two adult reconstruction, two trauma, two spine) were tested before surgery with an ATP bioluminescence assay kit. All of the cases were considered clean surgery without infection, and this included the previously performed cases in each sampled room. These rooms had been cleaned and prepped for surgery but the patients had not been physically brought into the room. A total of 13 different surfaces were sampled once in each room: the operating room (OR) preparation table (both pre- and postdraping), OR light handles, Bovie machine buttons, supply closet countertops, the inside of the Bair Hugger™ hose, Bair Hugger™ buttons, right side of the OR table headboard, tourniquet machine buttons, the Clark-socket attachment, and patient positioners used for total hip and spine positioning. The relative light units (RLUs) obtained from each sample were recorded and data were compiled and averaged for analysis. These values were compared with previously published ATP benchmark values of 250 to 500 RLUs to define cleanliness in both the hospital and restaurant industries. All surfaces had bioburden. The ATP RLUs (mean ± SD) are reported for each surface in ascending order: the OR preparation table (postdraping; 8.3 ± 3.4), inside the sterilized pan (9.2 ± 5.5), the inside of the Bair Hugger™ hose (212.5 ± 155.7), supply closet countertops (281.7 ± 236.7), OR light handles (647.8 ± 903.7), the OR preparation table (predraping; 1054 ± 387.5), the Clark-socket attachment (1135.7 ± 705.3), patient positioners used for total hip and spine positioning (1201.7 ± 1144.9), Bovie machine buttons (1264.5 ± 638.8), Bair Hugger™ buttons (1340.8 ± 1064.1), tourniquet machine buttons (1666.5 ± 2144.9), computer keyboard (1810.8 ± 929.6), and the right side of the OR table headboard (2539 ± 5635.8). ATP bioluminescence is a novel method to measure cleanliness within the orthopaedic OR and can help identify environmental trouble spots that can potentially lead to increased infection rates. Future studies correlating ATP bioluminescence findings with microbiology cultures could add to the clinical utility of this technology. Surfaces such as the undersurface of the OR table headboard, Bair Hugger™ buttons, and tourniquet machine buttons should be routinely cleansed as part of an institutional protocol. Although correlation between ATP bioluminescence and clinical infection was not evaluated in this study, it is the subject of future research. Specifically, evaluating microbiology samples taken from these environmental surfaces and correlating them with increased bioburden found with ATP bioluminescence technology can help promote improved surgical cleaning practices.
Increasing smoke alarm operability through theory-based health education: a randomised trial.
Miller, Ted R; Bergen, Gwen; Ballesteros, Michael F; Bhattacharya, Soma; Gielen, Andrea Carlson; Sheppard, Monique S
2014-12-01
Although working smoke alarms halve deaths in residential fires, many households do not keep alarms operational. We tested whether theory-based education increases alarm operability. Randomised multiarm trial, with a single arm randomly selected for use each day, in low-income neighbourhoods in Maryland, USA. Intervention arms: (1) Full Education combining a health belief module with a social-cognitive theory module that provided hands-on practice installing alarm batteries and using the alarm's hush button; (2) Hands-on Practice social-cognitive module supplemented by typical fire department education; (3) Current Norm receiving typical fire department education only. Four hundred and thirty-six homes recruited through churches or by knocking on doors in 2005-2008. Follow-up visits checked alarm operability in 370 homes (85%) 1-3.5 years after installation. number of homes with working alarms defined as alarms with working batteries or hard-wired and number of working alarms per home. Regressions controlled for alarm status preintervention; demographics and beliefs about fire risks and alarm effectiveness. Homes in the Full Education and Practice arms were more likely to have a functioning smoke alarm at follow-up (OR=2.77, 95% CI 1.09 to 7.03) and had an average of 0.32 more working alarms per home (95% CI 0.09 to 0.56). Working alarms per home rose 16%. Full Education and Practice had similar effectiveness (p=0.97 on both outcome measures). Without exceeding typical fire department installation time, installers can achieve greater smoke alarm operability. Hands-on practice is key. Two years after installation, for every three homes that received hands-on practice, one had an additional working alarm. http://www.clinicaltrials.gov number NCT00139126. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Automatic multiple-sample applicator and electrophoresis apparatus
NASA Technical Reports Server (NTRS)
Grunbaum, B. W. (Inventor)
1977-01-01
An apparatus for performing electrophoresis and a multiple-sample applicator is described. Electrophoresis is a physical process in which electrically charged molecules and colloidal particles, upon the application of a dc current, migrate along a gel or a membrane that is wetted with an electrolyte. A multiple-sample applicator is provided which coacts with a novel tank cover to permit an operator either to depress a single button, thus causing multiple samples to be deposited on the gel or on the membrane simultaneously, or to depress one or more sample applicators separately by means of a separate button for each applicator.
Saikaly, Sami K; Rich, Mark A; Swana, Hubert S
2016-08-01
The Malone antegrade continence enema (MACE) procedure is performed for patients with fecal incontinence and constipation who do not respond to medical therapy. The MACE procedure provides antegrade catheter access to the right colon and allows administration of enemas to help evacuate the bowel regularly. The objective of this study was to identify risk factors for surgical complications in children who undergo the MACE procedure. Records from 97 pediatric patients who underwent MACE procedure were reviewed retrospectively. Data collected included age, sex, weight (obese/not obese), stomal location, presence of a permanent button/catheter in the stoma, open vs. laparoscopic surgery, and etiology of fecal incontinence/constipation. The complications reviewed included stomal stenosis, leakage, and stomal site infection. The relationships between the independent variables and complications were assessed using chi-square tests and Fisher's exact test. Statistical significance was set at p < 0.05. Overall, 66 (68%) patients had at least one complication. Twenty-three (23.7%) patients developed stomal stenosis, and 27 (27.8%) patients had significant stomal leakage. Insertion of a stomal button/catheter device was associated with an increased risk of developing stomal leakage and stomal infection. The presence of a stomal button/catheter was also associated with a decreased risk of stomal stenosis (Figure). The non-intubated, imbricated sub-population, preteen patients (<12 years old) experienced more stomal leakage than teenage patients. In this subgroup, patients with umbilical stomas also experienced more leakage than patients with right lower quadrant (RLQ) stomas. The prevalence rates of stomal complications in our study were consistent with previously reported series. In our study, however, stomal leakage had a higher prevalence in comparison with stomal stenosis. This seems to be related to the heterogeneity of the study group, which contained two variants of the MACE procedure; non-imbricated, intubated MACE and imbricated, non-intubated MACE. The use of stomal buttons in conjunction with MACE has previously been reported without changes in complication rates. We found the use of stomal buttons/catheters to be associated with changes in the prevalence of stomal complications. Stomal complications are common in the MACE procedure. The use of a permanent stomal button/catheter is associated with changes in the rates of stomal complications. While many find an umbilical stomal site is more cosmetically appealing, there is an increased risk of leakage with imbricated, non-intubated stomas. In the non-intubated, imbricated sub-population, the MACE procedure results in a higher risk of stomal leakage in preteen patients in comparison with teenage patients. Copyright © 2016 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
Is it, or isn't it? Poison ivy look-a-likes.
McGovern, T W; LaWarre, S R; Brunette, C
2000-06-01
Poison ivy causes more allergic contact dermatitis (ACD) than any other cause. Although physicians rightfully focus on the treatment of the dermatitis, prevention will be aided by recognition of the foreboding plant. Likewise, many other plants can masquerade as poison ivy and cause one to needlessly curtail his or her activities because of fear of a bad reaction. The most common poison ivy pretenders in the United States are discussed, and distinguishing plant characteristics are highlighted.
Intraosseous ameloblastoma masquerading as exophytic growth: a case report
David, Chaya M; Kaul, Rachna; BK, Ramnarayan; Ramachandra, Prashanth
2011-01-01
Intraosseous ameloblastoma is the most common and simple type of ameloblastoma prevalent among odontogenic tumors. Clinico-radiographically intraosseous ameloblastoma presents as slow, painless swelling or expansion of the jaws and described as multilocular expansile radiolucency that occurs most frequently in mandibular molar/ramus area. This article describes a case of follicular ameloblastoma involving 45 year old male which is different from the usual presentation, which includes-exophytic growth, different location and without expansion of the cortex. PMID:21977481
Selvi, Subramanian Kalaivani; Kar, Rakhee; Vadivelan, Mehalingam; Subrahmanyam, Dharanipragada Krishna Suri
2012-01-01
Bone marrow fat embolism usually occurs following multiple bone fractures, intraosseous surgical procedures, following vigorous cardiac resuscitation, ecclampsia, sickle cell anemia, malignancies, etc. We present a case of 70-year-old male who presented with fever, cough with expectoration, respiratory distress, altered sensorium, hypotension and thrombocytopenia, and diagnosed to have dengue shock syndrome and expired within 1 day of admission. Postmortem lung biopsy revealed bone marrow fat embolism.
Metastatic Male Ductal Breast Cancer Mimicking Obstructing Primary Colon Cancer
Koleilat, Issam; Syal, Anil; Hena, Muhammad
2010-01-01
Male breast cancer comprises only about 1% of all breast cancers. Commonly, sites of metastases include the central nervous system, lungs, bones, and even liver. In females, extrahepatic gastrointestinal metastases are unusual but have been reported with various clinical presentations. We are reporting the first case of a male patient with a history of ductal breast carcinoma that developed colonic metastasis and presented with mechanical large bowel obstruction masquerading as primary colon cancer. PMID:23675178
Plague Masquerading as Gastrointestinal Illness
Hull, Harry F.; Montes, Jean M.; Mann, Jonathan M.
1986-01-01
In clinical descriptions of human plague, fever and tender lymphadenitis are emphasized and gastrointestinal manifestations are rarely mentioned. A review of 71 human plague cases showed that gastrointestinal symptoms occurred commonly (57%). Vomiting (39%) was the most frequent symptom, with nausea (34%), diarrhea (28%) and abdominal pain (17%) occurring less often. Physicians treating patients who reside in or have recently visited plague-endemic areas should include plague in the differential diagnosis in the presence of gastrointestinal symptoms and fever. PMID:3788132
NEUROSARCOIDOSIS MASQUERADING AS A CENTRAL NERVOUS SYSTEM TUMOR.
Elia, Maxwell; Kombo, Ninani; Huang, John
2017-01-01
To report a case of neurosarcoidosis with an isolated brain lesion mimicking a low-grade glioma. A 38-year-old woman presented with 2 weeks of blurry vision in the left eye. Ophthalmic examination, visual field testing, fluorescein angiography, laboratory testing, and MRI of the brain were performed. Ophthalmic examination revealed left-sided optic nerve infiltration, and MRI of the brain demonstrated a solitary lesion in the brain. The visual symptoms and ophthalmic examination improved significantly with initiation of high-dose oral prednisone. Because the MRI appearance was concerning for malignancy, a brain biopsy was performed. Pathology demonstrated gliosis consistent with a low-grade central nervous system (CNS) glioma. One year later, after initial loss to ophthalmic follow-up, the right optic nerve became involved, and the patient was again treated successfully for presumed ocular sarcoidosis. At this time, serial neuroimaging demonstrated enlargement of the CNS lesion, prompting rebiopsy. Rebiopsy demonstrated a noncaseating granuloma, confirming the diagnosis of neurosarcoidosis. The patient was treated with 20 mg of methotrexate weekly and a prednisone taper with improvement in visual and neurologic symptoms. The authors present an unusual case of neurosarcoidosis masquerading as a CNS glioma. In cases of solitary CNS granulomas, radiographically differentiating neurosarcoidosis from a glioma can be challenging. In this case, serial ophthalmic examination identifying sequential involvement of both optic nerves helped to identify the underlying cause of the CNS disease as sarcoidosis.
Rasić, D M; Stanković, Z; Terzić, T; Kovacević, D; Koturović, Z; Marković, V
2010-09-01
To report a clinical, histopathological and immunohistochemical findings in a case of primary extranodal marginal zone lymphoma of the uvea associated with massive diffuse extraocular episcleral extension and focal infiltration of the optic nerve and meninges, clinically presented as longstanding uveitis masquerade syndrome. Interventional case reports with histopathological correlation. We describe a 80-year-old male patient with a 3-year history of chronic recurrent hypertensive (pan) uveitis associated with ocular pain, unresponsive to topical and systemic anti-inflammatory, immunosuppressive, antibiotic/antiviral and antiglaucomatous therapy. Because the eye was not salvageable with conservative treatment, enucleation of blind and painful eye was performed. Findings from histopathological and immunohistochemistry examination of the enucleated eye showed an extranodal marginal zone lymphoma of the uveal tract with massive epibulbar extension and optic nerve and meningeal penetration. During almost 3 years of clinical course and 6 months after the enucleation, there were no systemic manifestations of lymphoma, and patient has not required subsequent treatment. Primary lymphoproliferative lesions of the uvea, comprising the iris, ciliary body and choroid are very rare, associated with epibulbar extension extremely and with optic nerve and menigeal penetration exceptionally. Despite its rarity, primary lymphoma of the uvea should be included in the differential diagnosis particularly in older patients with longstanding recurrent uveitis.
Security enhanced multi-factor biometric authentication scheme using bio-hash function.
Choi, Younsung; Lee, Youngsook; Moon, Jongho; Won, Dongho
2017-01-01
With the rapid development of personal information and wireless communication technology, user authentication schemes have been crucial to ensure that wireless communications are secure. As such, various authentication schemes with multi-factor authentication have been proposed to improve the security of electronic communications. Multi-factor authentication involves the use of passwords, smart cards, and various biometrics to provide users with the utmost privacy and data protection. Cao and Ge analyzed various authentication schemes and found that Younghwa An's scheme was susceptible to a replay attack where an adversary masquerades as a legal server and a user masquerading attack where user anonymity is not provided, allowing an adversary to execute a password change process by intercepting the user's ID during login. Cao and Ge improved upon Younghwa An's scheme, but various security problems remained. This study demonstrates that Cao and Ge's scheme is susceptible to a biometric recognition error, slow wrong password detection, off-line password attack, user impersonation attack, ID guessing attack, a DoS attack, and that their scheme cannot provide session key agreement. Then, to address all weaknesses identified in Cao and Ge's scheme, this study proposes a security enhanced multi-factor biometric authentication scheme and provides a security analysis and formal analysis using Burrows-Abadi-Needham logic. Finally, the efficiency analysis reveals that the proposed scheme can protect against several possible types of attacks with only a slightly high computational cost.
Nayak, Prakash Chandra; Raju, C V; Lakshmisha, I P; Singh, Rajkumar Ratankumar; Sofi, Faisal Rashid
2015-06-01
The ability of button mushroom (Agaricus bisporus) in changing physical, chemical, microbial and sensory properties of fish patties prepared from sutchi catfish (Pangasius hypophthalmus) was investigated. Two batches of fresh patties were prepared, one batch was treated with 15 % button mushroom (TP) and other batch was a control (CP) without mushroom. The patties were packed in polythene bags and stored under refrigerated condition (6 ± 2 ºC) without adding any preservatives for the estimation of storage stability. The analyses of patties were conducted at regular intervals of 3 days. The results showed that, Peroxide value, Thiobarbituric acid value, Free fatty acids increased significantly in CP at the end of 12 days whereas the TP was within the acceptable limit up to 16 days. Total volatile base nitrogen and Trimethylamine nitrogen also showed a similar trend. The Total plate count and Aerobic spore formers showed an increasing trend in CP when compared to TP. The sensory scores showed that the overall acceptability of CP were lower than TP, which was acceptable even after 16 days of storage. The present study showed that, the quality and storage stability of TP were observed to be in good condition up to 16 days and started deteriorating 20th day onwards, whereas the CP were acceptable only up to 12 days. Therefore it can be recommended that, addition of 15 % of button mushroom to sutchi catfish patty not only increases the nutritional quality but also increases the shelf life of patties under refrigerated storage.
Ota, Kazuhiro; Nouda, Sadaharu; Takeuchi, Toshihisa; Iguchi, Munetaka; Kojima, Yuichi; Kuramoto, Takanori; Inoue, Takuya; Shindo, Yasunori; Uesugi, Kenshiro; Fujito, Yoshiaki; Nishihara, Hironori; Ohtsuka, Naotake; Higuchi, Kazuhide
2015-01-01
Background We have been developing the Self-Propelling Capsule Endoscope (SPCE) that allows for controllability from outside of the body and real-time observation. What kind of capsule endoscope (CE) is suitable for a controllable SPCE is unclear and a very critical point for clinical application. We compared observing ability of three kinds of SPCEs with different viewing angles and frame rates. Methods Eleven buttons were sewed in an excised porcine stomach. Four examiners controlled the SPCE using PillCamSB2, -ESO2, and -COLON2 (Given Imaging Ltd., Israel), for 10 minutes each with the aim of detecting as many buttons and examining them as closely as possible. The ability to find lesions was assessed based on the number of detected buttons. The SPCE-performance score (SPS) was used to evaluate the ability to examine the lesions in detail. Results The SPCE-ESO2, -COLON2, and -SB2 detected 11 [interquartile range (IQR): 0], 10.5 (IQR, 0.5), and 8 (IQR, 1.0) buttons, respectively. The SPCE-ESO2 and -COLON2 had a significantly better ability to detect lesions than the -SB2 (p < 0.05). The SPCE-ESO2, -COLON2, and -SB2 had significantly different SPS values of 22 (IQR, 0), 16.5 (IQR, 1.5), and 14 (IQR, 1.0), respectively (p < 0.05 for all comparisons; SPCE-SB2 vs. -ESO2, -SB2 vs. -COLON2, and -ESO2 vs. -COLON2). Conclusions PillCamESO2 is most suitable in different three CEs for SPCE for examining lesions in detail of the stomach. PMID:26447694
Limb-kinetic apraxia affects activities of daily living in Parkinson’s disease: a multi-center study
Foki, T.; Vanbellingen, T.; Lungu, C.; Pirker, W.; Bohlhalter, S.; Nyffeler, T.; Kraemmer, J.; Haubenberger, D.; Fischmeister, F. Ph. S.; Auff, E.; Hallett, M.; Beisteiner, R.
2017-01-01
Background and purpose Impaired dexterity (fine hand movements) is often present in Parkinson’s disease (PD), even at early to moderate disease stages. It has a detrimental impact on activities of daily living (ADL) such as buttoning, contributing to reduced quality of life. Limb-kinetic apraxia, a loss of the ability to make precise, independent but coordinated finger and hand movements, may contribute to impaired dexterity even more than bradykinesia per se. However, the impact of limb-kinetic apraxia on ADL remains controversial. Our aim was to identify the strongest predictor of buttoning and unbuttoning in PD. It was hypothesized that coin rotation (a surrogate of limb-kinetic apraxia) represents the most important determinant. Methods Sixty-four right-handed, early to moderate PD patients were recruited from three movement disorder centers (Hoehn and Yahr stages 1–3). Buttoning, unbuttoning and coin rotation (right and left hand) represented the target tasks. Motor impairment was assessed according to the Unified Parkinson’s Disease Rating Scale. Results Multiple linear regression analysis showed that coin rotation with the right hand was the only significant predictor of buttoning (P < 0.001) and unbuttoning (P = 0.002). Notably, measures of bradykinesia or overall motor impairment did not represent significant predictors. Conclusions Constituting the novel key finding, limb-kinetic apraxia seems to be particularly relevant for ADL requiring dexterity skills in PD, even at early to moderate disease stages. Our results prompt research into the pathophysiological background and therapeutic options to treat limb-kinetic apraxia. The simple coin rotation test provides valuable information about ADL-related dexterity skills. PMID:27132653
Ota, Kazuhiro; Nouda, Sadaharu; Takeuchi, Toshihisa; Iguchi, Munetaka; Kojima, Yuichi; Kuramoto, Takanori; Inoue, Takuya; Shindo, Yasunori; Uesugi, Kenshiro; Fujito, Yoshiaki; Nishihara, Hironori; Ohtsuka, Naotake; Higuchi, Kazuhide
2015-01-01
We have been developing the Self-Propelling Capsule Endoscope (SPCE) that allows for controllability from outside of the body and real-time observation. What kind of capsule endoscope (CE) is suitable for a controllable SPCE is unclear and a very critical point for clinical application. We compared observing ability of three kinds of SPCEs with different viewing angles and frame rates. Eleven buttons were sewed in an excised porcine stomach. Four examiners controlled the SPCE using PillCamSB2, -ESO2, and -COLON2 (Given Imaging Ltd., Israel), for 10 minutes each with the aim of detecting as many buttons and examining them as closely as possible. The ability to find lesions was assessed based on the number of detected buttons. The SPCE-performance score (SPS) was used to evaluate the ability to examine the lesions in detail. The SPCE-ESO2, -COLON2, and -SB2 detected 11 [interquartile range (IQR): 0], 10.5 (IQR, 0.5), and 8 (IQR, 1.0) buttons, respectively. The SPCE-ESO2 and -COLON2 had a significantly better ability to detect lesions than the -SB2 (p < 0.05). The SPCE-ESO2, -COLON2, and -SB2 had significantly different SPS values of 22 (IQR, 0), 16.5 (IQR, 1.5), and 14 (IQR, 1.0), respectively (p < 0.05 for all comparisons; SPCE-SB2 vs. -ESO2, -SB2 vs. -COLON2, and -ESO2 vs. -COLON2). PillCamESO2 is most suitable in different three CEs for SPCE for examining lesions in detail of the stomach.
Meal Microstructure Characterization from Sensor-Based Food Intake Detection.
Doulah, Abul; Farooq, Muhammad; Yang, Xin; Parton, Jason; McCrory, Megan A; Higgins, Janine A; Sazonov, Edward
2017-01-01
To avoid the pitfalls of self-reported dietary intake, wearable sensors can be used. Many food ingestion sensors offer the ability to automatically detect food intake using time resolutions that range from 23 ms to 8 min. There is no defined standard time resolution to accurately measure ingestive behavior or a meal microstructure. This paper aims to estimate the time resolution needed to accurately represent the microstructure of meals such as duration of eating episode, the duration of actual ingestion, and number of eating events. Twelve participants wore the automatic ingestion monitor (AIM) and kept a standard diet diary to report their food intake in free-living conditions for 24 h. As a reference, participants were also asked to mark food intake with a push button sampled every 0.1 s. The duration of eating episodes, duration of ingestion, and number of eating events were computed from the food diary, AIM, and the push button resampled at different time resolutions (0.1-30s). ANOVA and multiple comparison tests showed that the duration of eating episodes estimated from the diary differed significantly from that estimated by the AIM and the push button ( p -value <0.001). There were no significant differences in the number of eating events for push button resolutions of 0.1, 1, and 5 s, but there were significant differences in resolutions of 10-30s ( p -value <0.05). The results suggest that the desired time resolution of sensor-based food intake detection should be ≤5 s to accurately detect meal microstructure. Furthermore, the AIM provides more accurate measurement of the eating episode duration than the diet diary.
Meal Microstructure Characterization from Sensor-Based Food Intake Detection
Doulah, Abul; Farooq, Muhammad; Yang, Xin; Parton, Jason; McCrory, Megan A.; Higgins, Janine A.; Sazonov, Edward
2017-01-01
To avoid the pitfalls of self-reported dietary intake, wearable sensors can be used. Many food ingestion sensors offer the ability to automatically detect food intake using time resolutions that range from 23 ms to 8 min. There is no defined standard time resolution to accurately measure ingestive behavior or a meal microstructure. This paper aims to estimate the time resolution needed to accurately represent the microstructure of meals such as duration of eating episode, the duration of actual ingestion, and number of eating events. Twelve participants wore the automatic ingestion monitor (AIM) and kept a standard diet diary to report their food intake in free-living conditions for 24 h. As a reference, participants were also asked to mark food intake with a push button sampled every 0.1 s. The duration of eating episodes, duration of ingestion, and number of eating events were computed from the food diary, AIM, and the push button resampled at different time resolutions (0.1–30s). ANOVA and multiple comparison tests showed that the duration of eating episodes estimated from the diary differed significantly from that estimated by the AIM and the push button (p-value <0.001). There were no significant differences in the number of eating events for push button resolutions of 0.1, 1, and 5 s, but there were significant differences in resolutions of 10–30s (p-value <0.05). The results suggest that the desired time resolution of sensor-based food intake detection should be ≤5 s to accurately detect meal microstructure. Furthermore, the AIM provides more accurate measurement of the eating episode duration than the diet diary. PMID:28770206
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fu, Wenkai; Ghosh, Priyarshini; Harrison, Mark
The performance of traditional Hornyak buttons and two proposed variants for fast-neutron hodoscope applications was evaluated using Geant4. The Hornyak button is a ZnS(Ag)-based device previously deployed at the Idaho National Laboratory's TRansient REActor Test Facility (better known as TREAT) for monitoring fast neutrons emitted during pulsing of fissile fuel samples. Past use of these devices relied on pulse-shape discrimination to reduce the significant levels of background Cherenkov radiation. Proposed are two simple designs that reduce the overall light guide mass (here, polymethyl methacrylate or PMMA), employ silicon photomultipliers (SiPMs), and can be operated using pulse-height discrimination alone to eliminatemore » background noise to acceptable levels. Geant4 was first used to model a traditional Hornyak button, and for assumed, hodoscope-like conditions, an intrinsic efficiency of 0.35% for mono-directional fission neutrons was predicted. The predicted efficiency is in reasonably good agreement with experimental data from the literature and, hence, served to validate the physics models and approximations employed. Geant4 models were then developed to optimize the materials and geometries of two alternatives to the Hornyak button, one based on a homogeneous mixture of ZnS(Ag) and PMMA, and one based on alternating layers of ZnS(Ag) and PMMA oriented perpendicular to the incident neutron beam. For the same radiation environment, optimized, 5-cm long (along the beam path) devices of the homogeneous and layered designs were predicted to have efficiencies of approximately 1.3% and 3.3%, respectively. For longer devices, i.e., lengths larger than 25 cm, these efficiencies were shown to peak at approximately 2.2% and 5.9%, respectively. Furthermore, both designs were shown to discriminate Cherenkov noise intrinsically by using an appropriate pulse-height discriminator level, i.e., pulse-shape discrimination is not needed for these devices.« less
METEOSAT studies of clouds and radiation budget
NASA Technical Reports Server (NTRS)
Saunders, R. W.
1982-01-01
Radiation budget studies of the atmosphere/surface system from Meteosat, cloud parameter determination from space, and sea surface temperature measurements from TIROS N data are all described. This work was carried out on the interactive planetary image processing system (IPIPS), which allows interactive manipulationion of the image data in addition to the conventional computational tasks. The current hardware configuration of IPIPS is shown. The I(2)S is the principal interactive display allowing interaction via a trackball, four buttons under program control, or a touch tablet. Simple image processing operations such as contrast enhancing, pseudocoloring, histogram equalization, and multispectral combinations, can all be executed at the push of a button.
Hiroshima neutron fluence on a glass button from near ground zero.
Fleischer, R L; Fujita, S; Hoshi, M
2001-12-01
A decorative glass button that was uncovered at a location that is 190 +/- 15 m from directly beneath the atomic explosion at Hiroshima on 6 August 1945 has been scanned for induced fission tracks produced mostly by the thermal neutrons from the bomb due to interactions with the trace uranium that is normally present in silicate glasses. In surveying 4.14 cm2 at 500x magnification, 28 tracks were seen. From a calibration irradiation in a nuclear reactor we infer that the neutron fluence in 1945 was 5.7(+/-1.1) x 10(11) cm(-2); and, allowing for shielding by the structure in which the button was probably located, the free-air (i.e., outside) value is estimated as 1.5(+/-0.5) x 10(12) cm(-2). A limit has been placed on possible fading of the radiation-damage tracks that could increase the fluence by at most a factor of 1.27. The values bracket the calculated value of 9 x 10(11) given in DS86 but are higher than the 3.6 x 10(11) inferred from induced radionuclides for the distance given. The difference is, however, within the observed variability of the two types of results.
Trelease, R B
1996-01-01
Advances in computer visualization and user interface technologies have enabled development of "virtual reality" programs that allow users to perceive and to interact with objects in artificial three-dimensional environments. Such technologies were used to create an image database and program for studying the human skull, a specimen that has become increasingly expensive and scarce. Stereoscopic image pairs of a museum-quality skull were digitized from multiple views. For each view, the stereo pairs were interlaced into a single, field-sequential stereoscopic picture using an image processing program. The resulting interlaced image files are organized in an interactive multimedia program. At run-time, gray-scale 3-D images are displayed on a large-screen computer monitor and observed through liquid-crystal shutter goggles. Users can then control the program and change views with a mouse and cursor to point-and-click on screen-level control words ("buttons"). For each view of the skull, an ID control button can be used to overlay pointers and captions for important structures. Pointing and clicking on "hidden buttons" overlying certain structures triggers digitized audio spoken word descriptions or mini lectures.
Zied, Diego Cunha; Penachio, Sara Maciel; Dias, Eustáquio Souza; de Almeida Minhoni, Marli Teixeira; Ferraz, Rafael Augusto; Vieites, Rogério Lopes
2014-11-01
The white button mushroom is the edible fungus most commonly cultivated and commercialized in Brazil and worldwide. This work assesses the productivity of the different strains ABI 07/06 and ABI 06/05 of Agaricus bisporus grown under the conditions normally employed by growers in the southeast of Brazil, and the influence of four different chemical conservation methods on the physicochemical characteristics and storage properties of the fruit bodies. The productivities of strains ABI 07/06 and ABI 06/05 of white button mushrooms were found to be comparable. The colorimetric characteristics and chemical compositions (fat, fiber and protein contents) of the mushroom strains were similar, and these parameters were not influenced significantly by the conservation processes. Texture was negatively affected by all processing methods employed. It was concluded that chemical methods of processing mushrooms were not fully effective and novel alternative technologies should be considered by mushroom processors in Brazil. Some methods of mushroom storage using chemicals such as sodium metabisulfite are harmful to the human organism, so processing using autoclaving may be the best form of conservation of canned mushrooms. © 2014 Society of Chemical Industry.
Dual-Band Dual-Mode Button Antenna for On-Body and Off-Body Communications.
Zhang, Xiu Yin; Wong, Hang; Mo, Te; Cao, Yun Fei
2017-08-01
A dual-band dual-mode button antenna for body centric communications is presented. At the lower band, a spiral inverted-F antenna is designed with omnidirectional radiation pattern for on-body communication. At the upper band, the high-order mode of the inverted-F antenna is utilized together with a metal reflector to realize broadside radiation for off-body communication. For demonstration, a prototype is implemented. The measured peak gains on the phantom at the lower and upper bands are -0.6 and 4.3 dBi, respectively. The antenna operating on the phantom has measured efficiencies of 46.3% at the lower band and 69.3% at the upper band. The issue of specific absorption rate (SAR) is studied. The maximum transmitted power under the SAR regulation of 1.6 W/kg is found to be 26.4 dB·m, which is high enough for body centric communications. In addition, the transmission performance between two proposed antennas mounted on the body is investigated by measuring the transmission loss. With an overall miniaturized size, the robust button antenna could be integrated in clothes and be a potential candidate for wireless body area network applications.
World Wide Web Metaphors for Search Mission Data
NASA Technical Reports Server (NTRS)
Norris, Jeffrey S.; Wallick, Michael N.; Joswig, Joseph C.; Powell, Mark W.; Torres, Recaredo J.; Mittman, David S.; Abramyan, Lucy; Crockett, Thomas M.; Shams, Khawaja S.; Fox, Jason M.;
2010-01-01
A software program that searches and browses mission data emulates a Web browser, containing standard meta - phors for Web browsing. By taking advantage of back-end URLs, users may save and share search states. Also, since a Web interface is familiar to users, training time is reduced. Familiar back and forward buttons move through a local search history. A refresh/reload button regenerates a query, and loads in any new data. URLs can be constructed to save search results. Adding context to the current search is also handled through a familiar Web metaphor. The query is constructed by clicking on hyperlinks that represent new components to the search query. The selection of a link appears to the user as a page change; the choice of links changes to represent the updated search and the results are filtered by the new criteria. Selecting a navigation link changes the current query and also the URL that is associated with it. The back button can be used to return to the previous search state. This software is part of the MSLICE release, which was written in Java. It will run on any current Windows, Macintosh, or Linux system.
Haptic Stylus and Empirical Studies on Braille, Button, and Texture Display
Kyung, Ki-Uk; Lee, Jun-Young; Park, Junseok
2008-01-01
This paper presents a haptic stylus interface with a built-in compact tactile display module and an impact module as well as empirical studies on Braille, button, and texture display. We describe preliminary evaluations verifying the tactile display's performance indicating that it can satisfactorily represent Braille numbers for both the normal and the blind. In order to prove haptic feedback capability of the stylus, an experiment providing impact feedback mimicking the click of a button has been conducted. Since the developed device is small enough to be attached to a force feedback device, its applicability to combined force and tactile feedback display in a pen-held haptic device is also investigated. The handle of pen-held haptic interface was replaced by the pen-like interface to add tactile feedback capability to the device. Since the system provides combination of force, tactile and impact feedback, three haptic representation methods for texture display have been compared on surface with 3 texture groups which differ in direction, groove width, and shape. In addition, we evaluate its capacity to support touch screen operations by providing tactile sensations when a user rubs against an image displayed on a monitor. PMID:18317520
Haptic stylus and empirical studies on braille, button, and texture display.
Kyung, Ki-Uk; Lee, Jun-Young; Park, Junseok
2008-01-01
This paper presents a haptic stylus interface with a built-in compact tactile display module and an impact module as well as empirical studies on Braille, button, and texture display. We describe preliminary evaluations verifying the tactile display's performance indicating that it can satisfactorily represent Braille numbers for both the normal and the blind. In order to prove haptic feedback capability of the stylus, an experiment providing impact feedback mimicking the click of a button has been conducted. Since the developed device is small enough to be attached to a force feedback device, its applicability to combined force and tactile feedback display in a pen-held haptic device is also investigated. The handle of pen-held haptic interface was replaced by the pen-like interface to add tactile feedback capability to the device. Since the system provides combination of force, tactile and impact feedback, three haptic representation methods for texture display have been compared on surface with 3 texture groups which differ in direction, groove width, and shape. In addition, we evaluate its capacity to support touch screen operations by providing tactile sensations when a user rubs against an image displayed on a monitor.
Voluntary and Involuntary Movements Widen the Window of Subjective Simultaneity.
Arikan, B Ezgi; van Kemenade, Bianca M; Straube, Benjamin; Harris, Laurence R; Kircher, Tilo
2017-01-01
Forming a coherent percept of an event requires different sensory inputs originating from the event to be bound. Perceiving synchrony aids in binding of these inputs. In two experiments, we investigated how voluntary movements influence the perception of simultaneity, by measuring simultaneity judgments (SJs) for an audiovisual (AV) stimulus pair triggered by a voluntary button press. In Experiment 1, we manipulated contiguity between the action and its consequences by introducing delays between the button press and the AV stimulus pair. We found a widened window of subjective simultaneity (WSS) when the action-feedback relationship was time contiguous. Introducing a delay narrowed the WSS, suggesting that the wider WSS around the time of an action might facilitate perception of simultaneity. In Experiment 2, we introduced an involuntary condition using an externally controlled button to assess the influence of action-related predictive processes on SJs. We found a widened WSS around the action time, regardless of movement type, supporting the influence of causal relations in the perception of synchrony. Interestingly, the slopes of the psychometric functions in the voluntary condition were significantly steeper than the slopes in the involuntary condition, suggesting a role of action-related predictive mechanisms in making SJs more precise.
Voluntary and Involuntary Movements Widen the Window of Subjective Simultaneity
Arikan, B. Ezgi; van Kemenade, Bianca M.; Straube, Benjamin; Harris, Laurence R.; Kircher, Tilo
2017-01-01
Forming a coherent percept of an event requires different sensory inputs originating from the event to be bound. Perceiving synchrony aids in binding of these inputs. In two experiments, we investigated how voluntary movements influence the perception of simultaneity, by measuring simultaneity judgments (SJs) for an audiovisual (AV) stimulus pair triggered by a voluntary button press. In Experiment 1, we manipulated contiguity between the action and its consequences by introducing delays between the button press and the AV stimulus pair. We found a widened window of subjective simultaneity (WSS) when the action-feedback relationship was time contiguous. Introducing a delay narrowed the WSS, suggesting that the wider WSS around the time of an action might facilitate perception of simultaneity. In Experiment 2, we introduced an involuntary condition using an externally controlled button to assess the influence of action-related predictive processes on SJs. We found a widened WSS around the action time, regardless of movement type, supporting the influence of causal relations in the perception of synchrony. Interestingly, the slopes of the psychometric functions in the voluntary condition were significantly steeper than the slopes in the involuntary condition, suggesting a role of action-related predictive mechanisms in making SJs more precise. PMID:28835813
Brabyn, Lars; Zawar-Reza, Peyman; Stichbury, Glen; Cary, Craig; Storey, Bryan; Laughlin, Daniel C; Katurji, Marwan
2014-04-01
The McMurdo Dry Valleys of Antarctica are the largest snow/ice-free regions on this vast continent, comprising 1% of the land mass. Due to harsh environmental conditions, the valleys are bereft of any vegetation. Land surface temperature is a key determinate of microclimate and a driver for sensible and latent heat fluxes of the surface. The Dry Valleys have been the focus of ecological studies as they arguably provide the simplest trophic structure suitable for modelling. In this paper, we employ a validation method for land surface temperatures obtained from Landsat 7 ETM + imagery and compared with in situ land surface temperature data collected from four transects totalling 45 iButtons. A single meteorological station was used to obtain a better understanding of daily and seasonal cycles in land surface temperatures. Results show a good agreement between the iButton and the Landsat 7 ETM + product for clear sky cases. We conclude that Landsat 7 ETM + derived land surface temperatures can be used at broad spatial scales for ecological and meteorological research.
Tuberculoid leprosy masquerading as systemic lupus erythematosus: an interesting observation.
Zawar, Vijay; Kumavat, Shrikant; Pawar, Manoj; Desai, Dipti
2017-09-01
Leprosy is a chronic granulomatous infectious multisystem disease that may present with protean manifestations. It mimics many systemic and dermatological disorders. Here we report a case in which an elderly female presented with malar rash, intermittent fever, and arthralgia. Her diagnosis was significantly delayed due to a close clinical resemblance to systemic lupus erythematosus. It is important to be aware of such manifestations of leprosy and improve awareness of it in clinicians to avoid misdiagnosis and delay in treatment.
Prominent subcutaneous oedema as a masquerading symptom of an underlying inflammatory myopathy.
Anantharajah, Anthea; Vucic, Steve; Tarafdar, Surjit; Vongsuvanh, Roslyn; Wilcken, Nicholas; Swaminathan, Sanjay
2017-02-01
The inflammatory myopathies are a group of immune-mediated inflammatory muscle disorders that typically present with marked proximal muscle weakness. We report four cases of inflammatory myopathies with marked subcutaneous oedema as their main complaint. Three of the four patients had normal or low levels of creatine kinase, an enzyme often markedly elevated in these disorders. Magnetic resonance imaging of the muscles, followed by a muscle biopsy were used to make a definitive diagnosis. © 2017 Royal Australasian College of Physicians.
Tuberculous otitis media -- a diagnostic dilemma.
Bhalla, R K; Jones, T M; Rothburn, M M; Swift, A C
2001-08-01
Tuberculous otitis media can provide a diagnostic challenge even to the most astute and experienced clinician. The rarity of the condition and its propensity to masquerade as commoner otological conditions further delays diagnosis and treatment. We present the case of a 22-year-old female who presented with chronic aural discharge, unilateral hearing loss and recurrent hemifacial paralysis. The paper highlights the difficulty in diagnosis and stresses the need for a high index of suspicion in cases resistant to the common methods of treatment.
Unal, M; Tuncer, C; Serçe, K; Bostan, M; Erem, C; Gökçe, M
1995-01-01
Cardiac echinococcosis is a very rare disease, especially in girls. We report a case of interventricular septum echinococcosis. A 14-year-old girl was referred for chest pain. Magnetic resonance imaging and two-dimensional echocardiography revealed a cyst in the distal interventricular septum. We concluded that MR imaging is useful in diagnosis and planning of surgery. Cardiac hydatid cyst should be considered in the differential diagnosis of patients with anginalike pain in endemic areas.
Lead toxicity masquerading as sickle cell crisis.
Nelson, M S; Chisolm, J J
1986-06-01
We recently saw a 12-year-old black boy with known sickle cell disease who had been seen many times for abdominal pain thought to be secondary to a vasoocclusive crisis. The patient eventually was admitted, after a seizure and the onset of obtundation. The etiology of his acute encephalopathy remained unclear until bone films of his knees fortuitously revealed "lead lines." The patient was treated and did well subsequently. This case emphasizes the importance of considering other diagnoses when a sickle cell patient presents with a crisis.
Tripathy, Sarthak; Mukherjee, Anirban; Bal, Chandrasekhar; Tripathi, Madhavi; Mallick, Saumyaranjan; Shamim, Shamim Ahmed
2017-01-01
Germ cell tumors (GCT) account for the 95% of the malignancies associated with testes. They are the most common solid malignancies affecting the males in the age group of 15–35 years. It is known to be bilateral in 3% of cases. We herein present FDG PET-CT findings of a case with biopsy proven GCT with multiple lymph nodal and splenic metastases mimicking lymphomatous neoplasm. PMID:28533651
Diffraction effects on angular response of X-ray collimators
NASA Technical Reports Server (NTRS)
Blake, R. L.; Barrus, D. M.; Fenimore, E.
1976-01-01
Angular responses have been measured for X-ray collimators with half-widths ranging from minutes of arc down to 10 arcsec. In the seconds-of-arc range, diffraction peaks at off-axis angles can masquerade as side lobes of the collimator angular response. Measurements and qualitative physical arguments lead to a rule of thumb for collimator design; namely, the angle of first minimum in the Fraunhofer single-slit diffraction pattern should be less than one-fourth of the collimator geometrical full-width at half-maximum intensity.
High Frontier: The Journal for Space & Missile Professionals. Volume 1, Number 3, Winter 2005
2005-01-01
masquerading as attempts to prevent the weaponization of space. China , for instance, is steadfast in their opposition to weaponizing space, and has brought...adversary, China , has both the intent and an expand- ing capability to exploit the vulnerability of US space systems in the event of a future...justification for US space programs.” He went on to discount any hostile Chinese intent, stating: “ China is interested in space but has done nothing
Thoracopulmonary actinomycosis: the masquerader.
Prabhu, S; Sripathi, H; Rao, R; Hameed, S
2008-05-01
Thoracopulmonary actinomycosis can mimic various lung pathologies such as bronchogenic carcinoma, tuberculosis and fungal pneumonia, to name but a few. The common causative agent is Actinomyces israelii. The disease is successfully diagnosed only if there is a high index of suspicion and a thorough evaluation with multidisciplinary involvement. We present a case of thoracopulmonary actinomycosis in a young immunocompetent man who did not have any predisposing illness, and who was treated initially for pulmonary tuberculosis. He showed good response to injection crystalline penicillin, which was later changed to oral amoxicillin.
Real time simulation application to monitor the stability limit of power system
NASA Astrophysics Data System (ADS)
Hartono, Kuo, Ming-Tse
2017-06-01
If the power system falls into an unsteady state, there will be voltage collapse in which the power system will be separated into small systems. Identifying the stability reserve in conformity with a certain practical operation condition is very important for the system management and operation. In fact, the global power system issue has caused serious outages due to voltage collapse such as in the United States-Canada in August 14, 2003; South London in August 28, 2003; southern Sweden and eastern Denmark in September 23, 2003; and Italy on September 28, 2003, and in Vietnam where power system problem led to power loss on 17 May 2005, 27 December 2006, 20 July 2007, and 10 September 2007. The analysis shows that the phenomenon is related to the loss of system stability. Thus, the operational system as well as the power system designs should be studied related to the issue of the system stability. To study the static stability of the power system, different approximate standards, called pragmatic criteria, were examined. Markovits has investigated the application of the standard of dP/dd to test the stability of the power button and dq/dU to check the voltage stability of the load button [1]. However, the storage stability when calculating standard dP/d d is usually much larger than the reserves when calculating standard dq/dU [1]. This paper presents a method to build a possible operation region in the power plane of load bus which works in comply with the stability limit to evaluate the stability reserve of the power system. This method is used to build a program to monitor the stability reserve of IEEE 39 Bus Power System in real time. To monitor the stability reserve of IEEE 39 nodes power system, articles based on the standard dq/dU was used to calculate the assessment. When using standard dq/dU to check for voltage stability load button, the amount of storage stability can be calculated by the following steps: first, transformed replacement scheme Masonry on the schematic rays of the source and node load stability was examined by using Gaussian elimination algorithm [1, 2, 3], then on the basis of ray diagrams the construction work, allowed domain of spare capacity load capacity in space and storage stability for the load button were determined. The GS-ODT program was built on the basis of Gaussian elimination algorithm and stable domain construction work algorithm for Masonic load button by dQ/dU pragmatic criteria. The GS-ODT program has a simple interface and easy to use with the main function is to identify the allowed domain for the load button and thus can assess visually stable reserve still according to the load capacity of the nodes of the IEEE 39 nodes power system in real-time.
Are Current Insulin Pumps Accessible to Blind and Visually Impaired People?
Burton, Darren M.; Uslan, Mark M.; Blubaugh, Morgan V.; Clements, Charles W.
2009-01-01
Background In 2004, Uslan and colleagues determined that insulin pumps (IPs) on the market were largely inaccessible to blind and visually impaired persons. The objective of this study is to determine if accessibility status changed in the ensuing 4 years. Methods Five IPs on the market in 2008 were acquired and analyzed for key accessibility traits such as speech and other audio output, tactual nature of control buttons, and the quality of visual displays. It was also determined whether or not a blind or visually impaired person could independently complete tasks such as programming the IP for insulin delivery, replacing batteries, and reading manuals and other documentation. Results It was found that IPs have not improved in accessibility since 2004. None have speech output, and with the exception of the Animas IR 2020, no significantly improved visual display characteristics were found. Documentation is still not completely accessible. Conclusion Insulin pumps are relatively complex devices, with serious health consequences resulting from improper use. For IPs to be used safely and independently by blind and visually impaired patients, they must include voice output to communicate all the information presented on their display screens. Enhancing display contrast and the size of the displayed information would also improve accessibility for visually impaired users. The IPs must also come with accessible user documentation in alternate formats. PMID:20144301
Are current insulin pumps accessible to blind and visually impaired people?
Burton, Darren M; Uslan, Mark M; Blubaugh, Morgan V; Clements, Charles W
2009-05-01
In 2004, Uslan and colleagues determined that insulin pumps (IPs) on the market were largely inaccessible to blind and visually impaired persons. The objective of this study is to determine if accessibility status changed in the ensuing 4 years. Five IPs on the market in 2008 were acquired and analyzed for key accessibility traits such as speech and other audio output, tactual nature of control buttons, and the quality of visual displays. It was also determined whether or not a blind or visually impaired person could independently complete tasks such as programming the IP for insulin delivery, replacing batteries, and reading manuals and other documentation. It was found that IPs have not improved in accessibility since 2004. None have speech output, and with the exception of the Animas IR 2020, no significantly improved visual display characteristics were found. Documentation is still not completely accessible. Insulin pumps are relatively complex devices, with serious health consequences resulting from improper use. For IPs to be used safely and independently by blind and visually impaired patients, they must include voice output to communicate all the information presented on their display screens. Enhancing display contrast and the size of the displayed information would also improve accessibility for visually impaired users. The IPs must also come with accessible user documentation in alternate formats. 2009 Diabetes Technology Society.
Sickle cell crisis presenting as a masquerade syndrome complicated by macular ischemia.
Makhoul, Dorine; Kolyvras, Nicolas; Benchekroun, Saad; Willermain, François; Caspers, Laure
2010-06-01
To report the case of a young boy, homozygous for the hemoglobin S, who presented a pseudouveitis in the setting of severe sickle cell retinopathy complicated by macular infarction. Case report. A 15 year-old boy with a history of hypertensive uveitis of two months duration was reffered to our institution. He was treated with topical prednisolone acetate, beta-blockers and acetazolamide.The visual acuity was 20/200 RE and 20/25 LE. Anterior inflammation included fine inferior keratic precipitates with 2+ cells RE and 1+ cells LE. Vitreous haze was 2+ preventing clear view of subretinal infiltrates scattered around the posterior pole and midperipheral retina, some of them having a salmon patch appearance. Fluorescein angiograms revealed multiple preretinal haemorrahge and some areas of retinal ischemia. Fundus examination of the left eye was normal. A diagnosis of panuveitis was done and a sickle cell retinopathy was suspected. Systemic workup showed an hemoglobin at 8,2 mg/dl and sickle cells on direct examination. Two days later he developed sudden loss of vision in the right eye. Funduscopy an angiogram revealed macular infarction with occlusion of the retinal arterioles surrounding the foveal avascular zone. The clinical picture was not improved by erythrocyte transfusion. Intraocular pressure raised again after few days, and was finally controlled by anterior chamber paracentesis. The patient was later found to be homozygous for HbS. Sickle cell retinopathy can rarely masquerade as panuveitis, and can lead to severe ocular complications as an irreversible macular ischemia.
Security enhanced multi-factor biometric authentication scheme using bio-hash function
Lee, Youngsook; Moon, Jongho
2017-01-01
With the rapid development of personal information and wireless communication technology, user authentication schemes have been crucial to ensure that wireless communications are secure. As such, various authentication schemes with multi-factor authentication have been proposed to improve the security of electronic communications. Multi-factor authentication involves the use of passwords, smart cards, and various biometrics to provide users with the utmost privacy and data protection. Cao and Ge analyzed various authentication schemes and found that Younghwa An’s scheme was susceptible to a replay attack where an adversary masquerades as a legal server and a user masquerading attack where user anonymity is not provided, allowing an adversary to execute a password change process by intercepting the user’s ID during login. Cao and Ge improved upon Younghwa An’s scheme, but various security problems remained. This study demonstrates that Cao and Ge’s scheme is susceptible to a biometric recognition error, slow wrong password detection, off-line password attack, user impersonation attack, ID guessing attack, a DoS attack, and that their scheme cannot provide session key agreement. Then, to address all weaknesses identified in Cao and Ge’s scheme, this study proposes a security enhanced multi-factor biometric authentication scheme and provides a security analysis and formal analysis using Burrows-Abadi-Needham logic. Finally, the efficiency analysis reveals that the proposed scheme can protect against several possible types of attacks with only a slightly high computational cost. PMID:28459867
Problems of internalization: a button is a button is-not.
Rockwell, Shelley
2014-01-01
Analysts hope to help the patient internalize a relationship with the analyst that contrasts with the original archaic object relation. In this paper, the author describes particular difficulties in working with a patient whose defenses and anxieties were bulimic, her movement toward internalization inevitably undone. Several issues are considered: how does the nonsymbolizing patient come to internalize the analyst's understanding, and when this does not hold, what is the nature of the patient's subsequent methods of dispersal? When the patient can maintain connection to the analyst as a good object, even fleetingly, in the depressive position, the possibility of internalization and symbolic communication is increased. © 2014 The Psychoanalytic Quarterly, Inc.
Pectoralis Major Repair With Unicortical Button Fixation And Suture Tape.
Sanchez, Anthony; Ferrari, Marcio B; Frangiamore, Salvatore J; Sanchez, George; Kruckeberg, Bradley M; Provencher, Matthew T
2017-06-01
Although injuries of the pectoralis major muscle are generally uncommon, ruptures of the pectoralis major are occasionally seen in younger, more active patients who participate in weightlifting activities. These injuries usually occur during maximal contraction of the muscle, while in extension and external rotation. In the case of a rupture, operative treatment is advocated especially in young, active patients regardless of the chronicity of the injury. Various surgical techniques for reattachment of the avulsed tendon have been described, but bone tunnel and suture anchor repair techniques are most widely used. In this Technical Note, we present our preferred technique for acute pectoralis major rupture repair involving use of cortical buttons for tendon stump-to-bone fixation.
Todor, Adrian; Caterev, Sergiu; Nistor, Dan Viorel; Khallouki, Youssef
2016-06-01
The most commonly used autografts for anterior cruciate ligament reconstruction are the bone-patellar tendon-bone and hamstring tendons. Each has its advantages and limitations. The bone-patellar tendon-bone autograft can lead to more donor-site morbidity, and the hamstring autograft can be unpredictable in size. The quadriceps tendon, with or without a bone block, has been described as an alternative graft source and has been used especially in revision cases, but in recent years, it has attracted attention even for primary cases. We report a technique for harvesting a free bone quadriceps tendon graft and attaching an extracortical button for femoral fixation for anterior cruciate ligament reconstruction.
Optics survivability support, volume 2
NASA Astrophysics Data System (ADS)
Wild, N.; Simpson, T.; Busdeker, A.; Doft, F.
1993-01-01
This volume of the Optics Survivability Support Final Report contains plots of all the data contained in the computerized Optical Glasses Database. All of these plots are accessible through the Database, but are included here as a convenient reference. The first three pages summarize the types of glass included with a description of the radiation source, test date, and the original data reference. This information is included in the database as a macro button labeled 'LLNL DATABASE'. Following this summary is an Abbe chart showing which glasses are included and where they lie as a function of nu(sub d) and n(sub d). This chart is also callable through the database as a macro button labeled 'ABBEC'.
NASA Technical Reports Server (NTRS)
Adams, Richard J.
2015-01-01
The patent-pending Glove-Enabled Computer Operations (GECO) design leverages extravehicular activity (EVA) glove design features as platforms for instrumentation and tactile feedback, enabling the gloves to function as human-computer interface devices. Flexible sensors in each finger enable control inputs that can be mapped to any number of functions (e.g., a mouse click, a keyboard strike, or a button press). Tracking of hand motion is interpreted alternatively as movement of a mouse (change in cursor position on a graphical user interface) or a change in hand position on a virtual keyboard. Programmable vibro-tactile actuators aligned with each finger enrich the interface by creating the haptic sensations associated with control inputs, such as recoil of a button press.
Mann J.R.; Wainwright, A.E.
1963-06-11
An automatic, personnel-operated, alpha-particle hand monitor is described which functions as a qualitative instrument to indicate to the person using it whether his hands are cold'' or hot.'' The monitor is activated by a push button and includes several capacitor-triggered thyratron tubes. Upon release of the push button, the monitor starts the counting of the radiation present on the hands of the person. If the count of the radiation exceeds a predetermined level within a predetermined time, then a capacitor will trigger a first thyratron tube to light a hot'' lamp. If, however, the count is below such level during this time period, another capacitor will fire a second thyratron to light a safe'' lamp. (AEC)
Manifold seal structure for fuel cell stack
Collins, William P.
1988-01-01
The seal between the sides of a fuel cell stack and the gas manifolds is improved by adding a mechanical interlock between the adhesive sealing strip and the abutting surface of the manifolds. The adhesive is a material which can flow to some extent when under compression, and the mechanical interlock is formed providing small openings in the portion of the manifold which abuts the adhesive strip. When the manifolds are pressed against the adhesive strips, the latter will flow into and through the manifold openings to form buttons or ribs which mechanically interlock with the manifolds. These buttons or ribs increase the bond between the manifolds and adhesive, which previously relied solely on the adhesive nature of the adhesive.
Mechanism of failure of the Cabrol procedure: A computational fluid dynamic analysis.
Poullis, M; Pullan, M
2015-12-01
Sudden failure of the Cabrol graft is common and frequently fatal. We utilised the technique of computational fluid dynamic (CFD) analysis to evaluate the mechanism of failure and potentially improve on the design of the Cabrol procedure. CFD analysis of the classic Cabrol procedure and a number of its variants was performed. Results from this analysis was utilised to generate further improved geometric options for the Cabrol procedure. These were also subjected to CFD analysis. All current Cabrol and variations of the Cabrol procedure are predicated by CFD analysis to be prone to graft thrombosis, secondary to stasis around the right coronary artery button. The right coronary artery flow characteristics were found to be the dominant reason for Cabrol graft failure. A simple modification of the Cabrol geometry is predicated to virtually eliminate any areas of blood stasis, and graft failure. Modification of the Cabrol graft geometry, due to CFD analysis may help reduce the incidence of graft thrombosis. A C shaped Cabrol graft with the right coronary button anastomosed to its side along its course from the aorta to the left coronary button is predicted to have the least thrombotic tendency. Clinical correlation is needed. Copyright © 2015 Elsevier Ltd. All rights reserved.
Grasp specific and user friendly interface design for myoelectric hand prostheses.
Mohammadi, Alireza; Lavranos, Jim; Howe, Rob; Choong, Peter; Oetomo, Denny
2017-07-01
This paper presents the design and characterisation of a hand prosthesis and its user interface, focusing on performing the most commonly used grasps in activities of daily living (ADLs). Since the operation of a multi-articulated powered hand prosthesis is difficult to learn and master, there is a significant rate of abandonment by amputees in preference for simpler devices. In choosing so, amputees chose to live with fewer features in their prosthesis that would more reliably perform the basic operations. In this paper, we look simultaneously at a hand prosthesis design method that aims for a small number of grasps, a low complexity user interface and an alternative method to the current use of EMG as a preshape selection method through the use of a simple button; to enable amputees to get to and execute the intended hand movements intuitively, quickly and reliably. An experiment is reported at the end of the paper comparing the speed and accuracy with which able-bodied naive subjects are able to select the intended preshapes through the use of a simplified EMG method and a simple button. It is shown that the button was significantly superior in the speed of successful task completion and marginally superior in accuracy (success of first attempt).
... Address What's this? Submit What's this? Submit Button Influenza Types Seasonal Avian Swine Variant Pandemic Other Pandemic Influenza Language: English (US) Español Recommend on Facebook Tweet ...
... Health International Recreational Water RWIs, Swimmer Hygiene, & Behavioral Science Historical CDC Manuals Health Promotion Materials Brochures Buttons & Banners Fact Sheets Infographics Clean It Up, Swimmers Make a ...
Jabłońska-Ryś, Ewa; Sławińska, Aneta; Radzki, Wojciech; Gustaw, Waldemar
2016-01-01
The available literature does not provide data on the application of probiotic strains in mushroom processing. The aim of the study was to evaluate the potential to use the L. plantarum 299v strain with documented probiotic properties in the process of lactic fermentation of button mushroom fruiting bodies (Agaricus bisporus). Fresh button mushroom fruiting bodies and cultures of lactic acid bacteria L. plantarum Ib and a probiotic strain L. plantarum 299v were the material analysed. Sensory evaluation was performed with a 5-point scale, an instrumental method of colour measurement based on the CIA L*a*b* scale, total phenolic compounds were determined with the Folin method, antioxidant properties were assayed with the DPPH radical test, and reducing power was determined using the FRAP method. After a week-long lactic fermentation, the pH value in the samples declined to a level of 3.6 (L. plantarum Ib) and 3.75 (L. plantarum 299v); these values persisted or decreased slightly during the period of maturation of the fermented samples under refrigeration. Fermented mushrooms were assigned high grades in the organoleptic evaluation. The colour analysis revealed significant changes in the values of the L*a*b* parameters in the fermented product, in comparison with fresh mushrooms. Blanching contributed to a significant decrease in the content of total phenolic compounds in the mushroom fruiting bodies and to a decline in antioxidant activity. Mushrooms fermented with the probiotic strain were characterised by higher phenolic compound content and higher antioxidant activity. L. plantarum 299v strain with documented probiotic properties can be applied in fermentation of button mushroom fruiting bodies. Products obtained with the use of both strains were characterised by good sensory properties. The type of strain used in the lactic fermentation of mushroom fruiting bodies had an effect on the phenolic compound content and antioxidant properties of the final product.
Modeling and test of a kinaesthetic actuator based on MR fluid for haptic applications.
Yang, Tae-Heon; Koo, Jeong-Hoi; Kim, Sang-Youn; Kwon, Dong-Soo
2017-03-01
Haptic display units have been widely used for conveying button sensations to users, primarily employing vibrotactile actuators. However, the human feeling for pressing buttons mainly relies on kinaesthetic sensations (rather than vibrotactile sensations), and little studies exist on small-scale kinaesthetic haptic units. Thus, the primary goals of this paper are to design a miniature kinaesthetic actuator based on Magneto-Rheological (MR) fluid that can convey various button-clicking sensations and to experimentally evaluate its haptic performance. The design focuses of the proposed actuator were to produce sufficiently large actuation forces (resistive forces) for human users in a given size constraint and to offer a wide range of actuation forces for conveying vivid haptic sensations to users. To this end, this study first performed a series of parametric studies using mathematical force models for multiple operating modes of MR fluid in conjunction with finite element electromagnetism analysis. After selecting design parameters based on parametric studies, a prototype actuator was constructed, and its performance was evaluated using a dynamic mechanical analyzer. It measured the actuator's resistive force with a varying stroke (pressed depth) up to 1 mm and a varying input current from 0 A to 200 mA. The results show that the proposed actuator creates a wide range of resistive forces from around 2 N (off-state) to over 9.5 N at 200 mA. In order to assess the prototype's performance in the terms of the haptic application prospective, a maximum force rate was calculated to determine just noticeable difference in force changes for the 1 mm stoke of the actuator. The results show that the force rate is sufficient to mimic various levels of button sensations, indicating that the proposed kinaesthetic actuator can offer a wide range of resistive force changes that can be conveyed to human operators.
[Outcomes and complications of Tightrope button plate for repairing acromioclavicular dislocation].
Zuo, Yong-Xiang; Ma, Zi-Ping
2017-10-25
To study the clinical outcome and complications of Tightrope button plate for repairing acromioclavicular dislocation of Rockwood type III to V. From May 2014 to December 2016, 17 patients with acromioclavicular dislocation of type III-V were treated with Tightrope button plate including 10 males and 7 females with an average age 39.8 years old ranging from 20 to 68 years old. Four patients were treated with arthroscopy and 17 patients were treated with mini-invasive by X-ray assisted. Shoulder function, X-ray and complications after operation were assessed. All patients were followed up for 5 to 23 months with a mean of 10.8 months. All patients got satisfying reduction immediately postoperatively. Among them, 1 case of clavicle end wound foreign body reaction, rupture, effusion, healing after the second suture; 1 case of foreign body granuloma formation at the end of clavicle were resected and removed at 4 months after operation; 3 cases loss reduction(less than 50% of acromioclavicular joint). No coracoid fracture and suture breakage observed. The shoulder mobility was restored in 15 cases at 4 to 6 weeks postoperatively, and the shoulder adhesion in 2 cases was delayed to 5 to 7 months after operation. The Constant scores were improved from 46.9±6.0 preoperatively to 92.7±4.0 at the final follow-up. X-ray evaluation of postoperative coracoclavicular tunnel location, patients' coracoclavicular tunnel with mini-invasive fluoroscopy all closed to the ideal position (across the clavicle vertically through the coracoid base center), while different degree of tunnel position deviation were observed in arthroscopic patients. Tightrope button plate for the treatment of acromioclavicular joint dislocation had advantages of minimally invasive, effective, good clinical results, the majority of common complications does not affect efficacy. Small incision X-ray method can provide more satisfactory and reliable tunnel location.
Mathaes, Roman; Mahler, Hanns-Christian; Vorgrimler, Lothar; Steinberg, Henrik; Dreher, Sascha; Roggo, Yves; Nieto, Alejandra; Brown, Helen; Roehl, Holger; Adler, Michael; Luemkemann, Joerg; Huwyler, Joerg; Lam, Philippe; Stauch, Oliver; Mohl, Silke; Streubel, Alexander
2016-01-01
The majority of parenteral drug products are manufactured in glass vials with an elastomeric rubber stopper and a crimp cap. The vial sealing process is a critical process step during fill-and-finish operations, as it defines the seal quality of the final product. Different critical capping process parameters can affect rubber stopper defects, rubber stopper compression, container closure integrity, and also crimp cap quality. A sufficiently high force to remove the flip-off button prior to usage is required to ensure quality of the drug product unit by the flip-off button during storage, transportation, and until opening and use. Therefore, the final product is 100% visually inspected for lose or defective crimp caps, which is subjective as well as time- and labor-intensive. In this study, we sealed several container closure system configurations with different capping equipment settings (with corresponding residual seal force values) to investigate the torque moment required to turn the crimp cap. A correlation between torque moment and residual seal force has been established. The torque moment was found to be influenced by several parameters, including diameter of the vial head, type of rubber stopper (serum or lyophilized) and type of crimp cap (West(®) or Datwyler(®)). In addition, we measured the force required to remove the flip-off button of a sealed container closure system. The capping process had no influence on measured forces; however, it was possible to detect partially crimped vials. In conclusion, a controlled capping process with a defined target residual seal force range leads to a tight crimp cap on a sealed container closure system and can ensure product quality. The majority of parenteral drug products are manufactured in a glass vials with an elastomeric rubber stopper and a crimp cap. The vial sealing process is a critical process step during fill-and-finish operations, as it defines the seal quality of the final product. An adequate force to remove the flip-off button prior to usage is required to ensure product quality during storage and transportation until use. In addition, the complete crimp cap needs to be fixed in a tight position on the vial. In this study, we investigated the torque moment required to turn the crimp cap and the force required to remove the flip-off button of container closure system sealed with different capping equipment process parameters (having different residual seal force values). © PDA, Inc. 2016.
Pediatric epidermoid cysts masquerading as ranulas: A case series.
Reddy, Abhita; Kreicher, Kathryn L; Patel, Neha A; Schantz, Stimson; Shinhar, Shai
2016-02-01
Pediatric neck masses represent a variety of differential diagnoses. A common pathology in pediatric cystic neck tumors include ranulas, mucus retention cysts due to salivary gland obstruction. Epidermoid cysts are lesions infrequently encountered in the pediatric population and may appear similarly to ranulas on computed tomography imaging. MRI more easily differentiates these masses, and should therefore be the preferred imaging modality. Due to their distinct intraoperative management, ranulas and epidermoid cysts should be distinguished preoperatively through proper workup. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Brice, Matthew E; Gossweiler, Marisa; Bennett, Larry
2017-03-01
Artifacts are universal across all imaging modalities, varying in their conspicuity and significance. In this report three patients with pathology-proven breast cancer who had densities masquerading as microcalcifications at the resection margins of the lumpectomy specimens, but had negative microscopic margins, will be discussed. It was determined that these pseudocalcifications were the result of ink precipitates from a commonly utilized tissue marking dye. This artifact was further evaluated and reproduced by utilizing a boneless chicken breast as a phantom. © RSNA, 2016.
Windshield safety glass foreign body masquerading as a root fragment.
Gray, S T
1994-02-01
A 42-year-old woman presented with a persistent radiopacity suggestive of an apparent root fragment after full dental clearance. This was caused by a foreign body lying within the buccal soft tissues. The foreign body was identified as a portion of soda-lime-silica glass which had penetrated during a road traffic accident but which had remained undetected for 6 years. Following its removal, further chemical analyses were undertaken to compare the radiographic characteristics of the windscreen glass in this case with other glass samples.
Aspartylglucosaminuria: psychomotor retardation masquerading as a mucopolysaccharidosis.
Isenberg, J N; Sharp, H L
1975-05-01
A 5-year-old girl with coarse facies, visceromegaly, and vacuolated lymphocytes is presented as the first case of aspartylglucosaminuria diagnosed in this country. This metabolic defect in glycoprotein catabolism can be clinically confused with other storage diseases such as the mucopolysaccharidoses and mucolipidoses. It is not diagnosed by routine laboratory screening methods. Special studies are required to confirm the diagnosis, but a thin-layer chromatography method for screening urine is presented for use when the diagnosis is suspected. The developmental potential in this inborn error of metabolism is documented.
Agrawal, Amit; Balpande, D N; Khan, A; Vagh, S J; Shukla, Samarth; Chopra, Sumit
2008-01-01
A 9-year-old female child presented with rapid neurological deterioration. Clinical features and imaging findings were suggestive of high-grade malignancy, and hematological investigations were suggestive of sickle cell trait. Histopathology showed features of low-grade malignancy and extensive intratumoral sickling. We hypothesize that the vicious cycle of hypoxia, sickling, thrombosis, ischemia and infarction resulted in the extensive tumor necrosis in the present case causing the initial symptoms and rapid deterioration in the condition of the patient. Copyright 2008 S. Karger AG, Basel.
Pakdel, Farzad; Hadizadeh, Homayoun; Pirmarzdashty, Niloofar; Kiavash, Victoria
2015-01-01
A 59-year-old patient developed acute proptosis, peri-orbital swelling and restriction of ocular movements 2 days after attempted scleral buckle removal. Initial clinical and orbital MRI findings were suggestive for orbital cellulitis and orbital abscess. Empiric intravenous antibiotics were not effective. Proton magnetic resonance spectroscopy (MRS) revealed a distinctive composition and helped rule out suppurative and neoplastic processes. The patient recovered soon after removing clear liquefied and tiny particles of the hydrogel buckle by an effective peristaltic technique.
Non-Newtonian gravity or gravity anomalies?
NASA Technical Reports Server (NTRS)
Rubincam, David P.; Chao, B. Fong; Schatten, Kenneth H.; Sager, William W.
1988-01-01
Geophysical measurements of G differ from laboratory values, indicating that gravity may be non-Newtonian. A spherical harmonic formulation is presented for the variation of (Newtonian) gravity inside the Earth. Using the GEM-10B Earth Gravitational Field Model, it is shown that long-wavelength gravity anomalies, if not corrected, may masquerade as non-Newtonian gravity by providing significant influences on experimental observation of delta g/delta r and G. An apparent contradiction in other studies is also resolved: i.e., local densities appear in equations when average densities of layers seem to be called for.
Cerebral Toxoplasmosis Masquerading Cns Lymphoma on FDG PET-CT in Post Renal Transplant Patient
Mukherjee, Anirban; Bal, Chandrasekhar; Tripathi, Madhavi; Das, Chandan Jyoti; Shamim, Shamim Ahmed
2017-01-01
20 year old post renal transplant patient developed recurrent episodes of seizure. MRI revealed focal lesion in right parieto-occipital lobe with perilesional edema. FDG PET-CT revealed multiple hypermetabolic lesions in bilateral cerebral hemisphere. Subsequent biopsy from the lesion demonstrated bradyzoites of Toxoplasma gondii with inflammatory cells and thereby, a confirmatory diagnosis of cerebral toxoplasmosis was made. This case demonstrates the fact that increased FDG uptake in cerebral lesions in post transplant patient should be interpreted with caution and confirmed with histopathological correlation. PMID:28533649
Broad Ligament Lipoleiomyoma Masses: Two curious cases masquerading as ovarian carcinomas.
Yadav, Surekha; Maheswari, Barkha; Sagar, Nishant; Mallya, Varuna; Khurana, Nita; Gupta, Sangeeta
2017-11-01
Lipoleiomyomas are an extremely rare form of uterine leiomyoma; moreover, the occurrence of this type of tumour on the broad ligament is even rarer. We report two cases of broad ligament lipoleiomyomas in 15- and 38-year-old female patients who presented to the Lok Nayak Jai Prakash Hospital in New Delhi, India, between 2016 and 2017. In both cases, the preoperative diagnosis was of a solid ovarian malignancy. Most broad ligament tumours are mistaken for ovarian masses as they are difficult to diagnose radiologically.
Focal cemento-osseous dysplasia masquerading as a residual cyst
Bhandari, Rajat; Sandhu, Simarpreet V.; Bansal, Himanta; Behl, Rashi; Bhullar, Ramanpreet Kaur
2012-01-01
Focal cemento-osseous dysplasia (FCOD) is a benign fibroosseous condition that can be seen in dentulous and edentulous patients. It is an asymptomatic lesion and needs no treatment; however, follow-up is essential due to the possibility that it can progress to a condition called florid cemento-osseous dysplasia. We report a case of FCOD of mandible in a 25-year-old female. Clinically, the lesion resembled periapical pathosis of odontogenic origin. An attempt has been made to discuss the clinical and histopathologic features along with differential diagnosis of cemento-osseous dysplasia. PMID:22629069
Focal cemento-osseous dysplasia masquerading as a residual cyst.
Bhandari, Rajat; Sandhu, Simarpreet V; Bansal, Himanta; Behl, Rashi; Bhullar, Ramanpreet Kaur
2012-04-01
Focal cemento-osseous dysplasia (FCOD) is a benign fibroosseous condition that can be seen in dentulous and edentulous patients. It is an asymptomatic lesion and needs no treatment; however, follow-up is essential due to the possibility that it can progress to a condition called florid cemento-osseous dysplasia. We report a case of FCOD of mandible in a 25-year-old female. Clinically, the lesion resembled periapical pathosis of odontogenic origin. An attempt has been made to discuss the clinical and histopathologic features along with differential diagnosis of cemento-osseous dysplasia.
Ross, Benjamin; Kumar, Manish; Srinivasan, Hema; Ekbote, Alka V
2016-08-08
Special diet with restricted branched-chain-amino-acids used for treating maple syrup urine disease can lead to specific amino acid deficiencies. We report a neonate who developed skin lesions due to isoleucine deficiency while using specialised formula. Feeds were supplemented with expressed breast milk. This caused biochemical and clinical improvement with resolution of skin lesions. Breast milk is a valuable and necessary adjunct to specialized formula in maple syrup urine disease to prevent specific amino acid deficiency in the neonatal period.
Large leiomyoma of the bladder masquerading as an enlarged prostate gland.
Itam, Sarah; Elhage, Oussama; Khan, Muhammad Shamim
2016-02-23
A 56-year-old man was admitted to hospital with shortness of breath and subsequently sustained a cardiac arrest. In the recovery period, he developed acute urinary retention and haematuria. Imaging suggested an enlarged prostate and he was started on clean intermittent catheterisation. Following further imaging and a transurethral biopsy, he was found to have a bladder leiomyoma. This was treated with laparotomy, cystotomy and enucleation of the tumour. At his 6-week follow-up appointment, he had a satisfactory cystogram and a successful void without catheter. 2016 BMJ Publishing Group Ltd.
Large leiomyoma of the bladder masquerading as an enlarged prostate gland
Itam, Sarah; Elhage, Oussama; Khan, Muhammad Shamim
2016-01-01
A 56-year-old man was admitted to hospital with shortness of breath and subsequently sustained a cardiac arrest. In the recovery period, he developed acute urinary retention and haematuria. Imaging suggested an enlarged prostate and he was started on clean intermittent catheterisation. Following further imaging and a transurethral biopsy, he was found to have a bladder leiomyoma. This was treated with laparotomy, cystotomy and enucleation of the tumour. At his 6-week follow-up appointment, he had a satisfactory cystogram and a successful void without catheter. PMID:26907817
Tumors masquerading in patients with thyroid eye disease.
Griepentrog, Gregory J; Burkat, Cat N; Kikkawa, Don O; Lucarelli, Mark J
2013-08-01
Thyroid eye disease (TED) is the most common cause of proptosis in adults. The external manifestations of TED are characteristic and the diagnosis is typically made without imaging. Although there are multiple descriptions of primary and secondary orbital tumors initially mistaken for TED in the literature, there are limited reports detailing the findings of patients with long-standing TED whom developed an orbital tumor at a later date. Herein, we present a 6-year retrospective multi-center report of three patients with long-standing TED who developed an initially unsuspected orbital or cavernous sinus tumor.
... Submit What's this? Submit Button Facts About Riot Control Agents Interim document Recommend on Facebook Tweet Share Compartir What riot control agents are Riot control agents (sometimes referred to ...
ERIC Educational Resources Information Center
Walker, Joseph J.; Lotz, Condit
1982-01-01
The authors describe an incidental learning approach using supplementary reading sources such as bumper stickers, t-shirts, and novelty buttons to encourage gifted students' analysis and synthesis skills. (CL)
Mosaic-Detector-Based Fluorescence Spectral Imager
NASA Technical Reports Server (NTRS)
Son, Kyung-Ah; Moon, Jeong
2007-01-01
A battery-powered, pen-sized, portable instrument for measuring molecular fluorescence spectra of chemical and biological samples in the field has been proposed. Molecular fluorescence spectroscopy is among the techniques used most frequently in laboratories to analyze compositions of chemical and biological samples. Heretofore, it has been possible to measure fluorescence spectra of molecular species at relative concentrations as low as parts per billion (ppb), with a few nm spectral resolution. The proposed instrument would include a planar array (mosaic) of detectors, onto which a fluorescence spectrum would be spatially mapped. Unlike in the larger laboratory-type molecular fluorescence spectrometers, mapping of wavelengths to spatial positions would be accomplished without use of relatively bulky optical parts. The proposed instrument is expected to be sensitive enough to enable measurement of spectra of chemical species at relative concentrations <1 ppb, with spectral resolution that could be tailored by design to be comparable to a laboratory molecular fluorescence spectrometer. The proposed instrument (see figure) would include a button-cell battery and a laser diode, which would generate the monochromatic ultraviolet light needed to excite fluorescence in a sample. The sample would be held in a cell bounded by far-ultraviolet-transparent quartz or optical glass. The detector array would be, more specifically, a complementary metal oxide/ semiconductor or charge-coupled- device imaging photodetector array, the photodetectors of which would be tailored to respond to light in the wavelength range of the fluorescence spectrum to be measured. The light-input face of the photodetector array would be covered with a matching checkerboard array of multilayer thin film interference filters, such that each pixel in the array would be sensitive only to light in a spectral band narrow enough so as not to overlap significantly with the band of an adjacent pixel. The wavelength interval between adjacent pixels (and, thus, the spectral resolution) would typically be chosen by design to be approximately equal to the width of the total fluorescence wavelength range of interest divided by the number of pixels. The unitary structure comprising the photodetector array overlaid with the matching filter array would be denoted a hyperspectral mosaic detector (HMD) array.
Herbal Extracts That Reduce Ocular Oxidative Stress May Enhance Attentive Performance in Humans.
Cho, Hohyun; Kwon, Moonyoung; Jang, Hyojung; Lee, Jee-Bum; Yoon, Kyung Chul; Jun, Sung Chan
2016-01-01
We used herbal extracts in this study to investigate the effects of blue-light-induced oxidative stress on subjects' attentive performance, which is also associated with work performance. We employed an attention network test (ANT) to measure the subjects' work performance indirectly and used herbal extracts to reduce ocular oxidative stress. Thirty-two subjects participated in either an experimental group (wearing glasses containing herbal extracts) or a control group (wearing glasses without herbal extracts). During the ANT experiment, we collected electroencephalography (EEG) and electrooculography (EOG) data and measured button responses. In addition, electrocardiogram (ECG) data were collected before and after the experiments. The EOG results showed that the experimental group exhibited a reduced number of eye blinks per second during the experiment and faster button responses with a smaller variation than did the control group; this group also showed relatively more sustained tension in their ECG results. In the EEG analysis, the experimental group had significantly greater cognitive processing, with larger P300 and parietal 2-6 Hz activity, an orienting effect with neural processing of frontal area, high beta activity in the occipital area, and an alpha and beta recovery process after the button response. We concluded that reducing blue-light-induced oxidative stress with herbal extracts may be associated with reducing the number of eye blinks and enhancing attentive performance.
A survey of fiber-positioning technologies
NASA Astrophysics Data System (ADS)
Smith, Greg; Brzeski, Jurek; Miziarski, Stan; Gillingham, Peter R.; Moore, Anna; McGrath, Andrew
2004-09-01
A wide range of positioning technologies has been exploited to flexibly configure fiber ends on the focal surfaces of telescopes. The earliest instruments used manual plugging, or glued buttons on the focal plane. Later instruments have used robotic fisherman-round-the-pond probes and articulated armsto position fibres, each probe or arm operated by its own motors, or buttons on fiber ends moved by pick-and-place robotic positioners. A positioner using fiber spines incorporating individual actuators operating over limited patrol areas is currently being manufactured and a derivative proposed for future large telescopes. Other techniques, using independent agents carrying the fiber ends about the focal plane have been prototyped. We describe these various fiber positioning techniques and compare them, listing the issues associated with their implementation, and consider the factors which make each of them suitable for a given situation. Factors considered include: robot geometries; costs; inherent limits to the number of fibers; clustering of targets; serial and parallel positioning and reconfiguration times; adaptability to curved focal surfaces; the virtues of on-telescope versus off-telescope configuration of the field, and suitability for the various telescope foci. The design issues include selection of actuators and encoding systems, counterbalancing, configuration of fiber buttons and their associated grippers, interchanging field plates, and the need for fiber retractors. Finally we consider the competing technologies: fiber and reflective image slicer IFUs, multislit masks and reconfigurable slits.
Swine Influenza/Variant Influenza Viruses
... Address What's this? Submit What's this? Submit Button Influenza Types Seasonal Avian Swine Variant Pandemic Other Information on Swine Influenza/Variant Influenza Virus Language: English (US) Español Recommend ...
Laboratory arc furnace features interchangeable hearths
NASA Technical Reports Server (NTRS)
Armstrong, J. L.; Kruger, O. L.
1967-01-01
Laboratory arc furnace using rapidly interchangeable hearths gains considerable versatility in casting so that buttons or special shaped castings can be produced. It features a sight glass for observation.
49 CFR 38.127 - Sleeping compartments.
Code of Federal Regulations, 2012 CFR
2012-10-01
... SPECIFICATIONS FOR TRANSPORTATION VEHICLES Intercity Rail Cars and Systems § 38.127 Sleeping compartments. (a...., heating and air conditioning controls, lighting controls, call buttons, electrical outlets, etc.) shall be...
49 CFR 38.127 - Sleeping compartments.
Code of Federal Regulations, 2013 CFR
2013-10-01
... SPECIFICATIONS FOR TRANSPORTATION VEHICLES Intercity Rail Cars and Systems § 38.127 Sleeping compartments. (a...., heating and air conditioning controls, lighting controls, call buttons, electrical outlets, etc.) shall be...
49 CFR 38.127 - Sleeping compartments.
Code of Federal Regulations, 2014 CFR
2014-10-01
... SPECIFICATIONS FOR TRANSPORTATION VEHICLES Intercity Rail Cars and Systems § 38.127 Sleeping compartments. (a...., heating and air conditioning controls, lighting controls, call buttons, electrical outlets, etc.) shall be...
49 CFR 38.127 - Sleeping compartments.
Code of Federal Regulations, 2011 CFR
2011-10-01
... SPECIFICATIONS FOR TRANSPORTATION VEHICLES Intercity Rail Cars and Systems § 38.127 Sleeping compartments. (a...., heating and air conditioning controls, lighting controls, call buttons, electrical outlets, etc.) shall be...
49 CFR 38.127 - Sleeping compartments.
Code of Federal Regulations, 2010 CFR
2010-10-01
... SPECIFICATIONS FOR TRANSPORTATION VEHICLES Intercity Rail Cars and Systems § 38.127 Sleeping compartments. (a...., heating and air conditioning controls, lighting controls, call buttons, electrical outlets, etc.) shall be...
... or buttons. It is important to rule out sexual abuse, rape, and assault. The health care provider should ... and: Pain, bleeding, or swelling A concern about sexual abuse Problems urinating Blood in the urine
... captioning, click the CC button on the lower right-hand corner of the player. Video player keyboard shortcuts Transcript Welcome to MedlinePlus, the consumer health information website from the National Library of ...
Help | About | Privacy | Media Room | Feedback Start Describe Compare Upgrade Learn Error: Your Session Timed Out, Please click the start button to restart. Write down your session id. Environmental
Burke, Emily L; Walvekar, Rohan R; Lin, James; Hagan, Joseph; Kluka, Evelyn A
2009-12-01
To determine the efficacy of common solutions used to dissolve blood clots blocking tympanostomy tubes (TTs) of differing lengths and diameters. An ex vivo experimental study. Ear models were built by the study investigator. Tympanostomy tubes were inserted into the models and blocked with blood clots. Test solutions were applied to the blood clots, and time for clearance was recorded via microscopic visual confirmation. Richards T-tube had higher odds of unclogging than collar button tubes (odds ratio: 2.37, 95% confidence intervals 1.02-5.54, p=0.042). Vinegar and 3% hydrogen peroxide were most effective for Richards T-tubes and collar button tubes, respectively. Common solutions (vinegar and hydrogen peroxide) were more effective than antibiotic drops in clearing blood clot blocking TTs.
Programmable diagnostic devices made from paper and tape.
Martinez, Andres W; Phillips, Scott T; Nie, Zhihong; Cheng, Chao-Min; Carrilho, Emanuel; Wiley, Benjamin J; Whitesides, George M
2010-10-07
This paper describes three-dimensional microfluidic paper-based analytical devices (3-D microPADs) that can be programmed (postfabrication) by the user to generate multiple patterns of flow through them. These devices are programmed by pressing single-use 'on' buttons, using a stylus or a ballpoint pen. Pressing a button closes a small space (gap) between two vertically aligned microfluidic channels, and allows fluids to wick from one channel to the other. These devices are simple to fabricate, and are made entirely out of paper and double-sided adhesive tape. Programmable devices expand the capabilities of microPADs and provide a simple method for controlling the movement of fluids in paper-based channels. They are the conceptual equivalent of field-programmable gate arrays (FPGAs) widely used in electronics.
NASA Technical Reports Server (NTRS)
Darlow, M. S.; Smalley, A. J.
1977-01-01
A test rig designed to measure stiffness and damping of elastomer cartridges under a rotating load excitation is described. The test rig employs rotating unbalance in a rotor which runs to 60,000 RPM as the excitation mechanism. A variable resonant mass is supported on elastomer elements and the dynamic characteristics are determined from measurements of input and output acceleration. Five different cartridges are considered: three of these are buttons cartridges having buttons located in pairs, with 120 between each pair. Two of the cartridges consist of 360 elastomer rings with rectangular cross-sections. Dynamic stiffness and damping are measured for each cartridge and compared with predictions at different frequencies and different strains.
... can easily inhale small foods (nuts, seeds, or popcorn) and objects (buttons, beads, or parts of toys) ... foods such as hot dogs, whole grapes, nuts, popcorn, food with bones, or hard candy to children ...
enter or select the go button to submit request City, St Go Science Research and Collaboration Hydrology River Forecasts, January 2002 AMS Short Course on Quantitative Precipitation Estimation and Forecasting
Swine Influenza (Swine Flu) in Pigs
... Address What's this? Submit What's this? Submit Button Influenza Types Seasonal Avian Swine Variant Pandemic Other Key Facts about Swine Influenza (Swine Flu) in Pigs Language: English (US) Español ...
... for Prevention Birth Defects are Common, Costly, and Critical Videos & Podcasts Buttons Prevent to Protect PACT Quiz ... front part of the brain (forebrain) and the thinking and coordinating part of the brain (cerebrum). The ...
code. Press enter or select the go button to submit request Local forecast by "City, St" City , St Go Search NCEP Go Current Hazards Watches/Warnings Outlooks National Current Conditions
45 CFR 73.735-602 - Permissible activities.
Code of Federal Regulations, 2011 CFR
2011-10-01
... political management or political campaigns or using official authority or influence to interfere with an... or button; (4) Participate in the nonpartisan activities of a civic, community, social, labor, or...
45 CFR 73.735-602 - Permissible activities.
Code of Federal Regulations, 2010 CFR
2010-10-01
... political management or political campaigns or using official authority or influence to interfere with an... or button; (4) Participate in the nonpartisan activities of a civic, community, social, labor, or...
Geraci, Girolamo; Sciume', Carmelo; Di Carlo, Giovanni; Picciurro, Antonino; Modica, Giuseppe
2016-11-04
Ingestion of foreign bodies and food impaction represent the second most common endoscopic emergency after bleeding. The aim of this paper is to report the management and the outcomes in 67 patients admitted for suspected ingestion of foreign body between December 2012 and December 2014. This retrospective study was conducted at Palermo University Hospitals, Italy, over a 2-year period. We reviewed patients' database (age, sex, type of foreign body and its anatomical location, treatments, and outcomes as complications, success rates, and mortalities). Foreign bodies were found in all of our 67 patients. Almost all were found in the stomach and lower esophagus (77 %). The types of foreign body were very different, but they were chiefly meat boluses, fishbones or cartilages, button battery and dental prostheses. In all patients it was possible to endoscopically remove the foreign body. Complications related to the endoscopic procedure were unfrequent (about 7 %) and have been treated conservatively. 5.9 % of patients had previous esophageal or laryngeal surgery, and 8.9 % had an underlying esophageal disease, such as a narrowing, dismotility or achalasia. Our experience with foreign bodies and food impaction emphasizes the importance of endoscopic approach and removal, simple and secure when performed by experienced hands and under conscious sedation in most cases. High success rates, lower incidence of minor complications, reduction of the need of surgery and reduced hospitalization time are the strengths of the endoscopic approach.
Katsinelos, Panagiotis; Kountouras, Jannis; Paroutoglou, George; Zavos, Christos; Mimidis, Kostas; Chatzimavroudis, Grigoris
2006-10-01
Ingested foreign bodies and food bolus impaction are frequently seen in endoscopic practice. Successful foreign body and food bolus removal may depend on the method used, the choice of device, and the experience level of the endoscopist, although few papers report experience and outcome of tertiary centers. To investigate the effectiveness of our protocol designed for removal of ingested foreign bodies and food boluses. We retrospectively reviewed all patients with a diagnosis of foreign body ingestion and food bolus impaction from 1994 to 2005 identified by computer search. Patients were excluded if medical record was incomplete. The analysis included 171 patients. Foreign bodies and impacted food boluses were found in 77 and 62 patients, respectively. In 32 cases (23%), the foreign bodies passed spontaneously through the gastrointestinal tract. The overall success rate for endoscopic management was obtained in 137 patients (98.6%). Surgical removal of a foreign body was required in only 2 cases (1.4%). According to the type and location of the foreign object and food bolus we used Dormia baskets, retrieval forceps, polypectomy snares, and all sizes of Roth net. No complications relating to the endoscopic procedure were observed; 50 patients (35.2%) had an underlying esophageal disease. Endoscopic removal of upper gastrointestinal tract foreign bodies and food bolus impaction is efficacious and safe. Especially the Roth net is the best device for safe retrieval of food boluses and button disc batteries.
Ocular myasthenia gravis: A review
Nair, Akshay Gopinathan; Patil-Chhablani, Preeti; Venkatramani, Devendra V; Gandhi, Rashmin Anilkumar
2014-01-01
Myasthenia gravis (MG) is a disease that affects the neuro-muscular junction resulting in classical symptoms of variable muscle weakness and fatigability. It is called the great masquerader owing to its varied clinical presentations. Very often, a patient of MG may present to the ophthalmologist given that a large proportion of patients with systemic myasthenia have ocular involvement either at presentation or during the later course of the disease. The treatment of ocular MG involves both the neurologist and ophthalmologist. Thus, the aim of this review was to highlight the current diagnosis, investigations, and treatment of ocular MG. PMID:25449931
Sivathapandi, Thangalakshmi; Amalachandran, Jaykanth; Simon, Shelley; Elangovan, Indirani
2018-01-01
The primary hypertrophic osteoarthropathy (PHOA) (pachydermoperiostosis) is a rare genetic/hereditary disease characterized by skin changes (pachydermia), clubbing of fingers and periosteal thickening (periostitis) with sub-periosteal new bone formation. Here we describe a case of an adolescent male who presented with clubbing and polyarthralgia. On evaluation with scintigraphy and SPECT-CT, he was diagnosed to have incomplete form of PHOA(skeletal manifestations without skin changes). The identification of incomplete form of primary hypertrophic osteoarthropathy which can be easily misdiagnosed as rheumatoid arthritis is discussed here.
2013-01-01
Background We describe the first case of a patient with factitious disorder who closely simulated a primary immune deficiency disorder – Common Variable Immune Deficiency (CVID), by surreptitiously ingesting non-steroidal anti-inflammatory agents. Case description He was treated with several expensive and potentially dangerous drugs before the diagnosis was established through collateral information. In retrospect he did not meet the proposed new criteria for CVID. These criteria may prove useful in distinguishing cases of CVID from secondary hypogammaglobulinemia. Conclusion It is imperative clinicians recognise patients with factitious disorder at the earliest opportunity to prevent iatrogenic morbidity and mortality. PMID:24341706
An Unusual Gross Appearance of Vulval Tuberculosis Masquerading as Tumor
Arakeri, Surekha U.
2014-01-01
Tuberculosis of the vulva is very rare. It is found in about 0.2% of the cases of genital tract tuberculosis. It usually presents as small shallow ulcers and multiple sinus tracts or rarely as elephantiasis of vulva. Except for very rare cases of primary tuberculosis in the vulva, it is usually associated with tuberculosis elsewhere in the body leading to secondary tuberculosis. Here, we report a case of secondary vulval tuberculosis which presented as a vulval mass in a 40-year-old female patient. The rarity of this presentation in the female genital tract is emphasized. PMID:25298898
Vennapusa, Bharathi; Oman, Sarah A; Parasher, Gulshan; Cerilli, Lisa A
2010-10-01
A 61-year-old woman with no significant past history underwent gastric biopsies demonstrating a strongly c-kit-positive epithelioid malignancy, initially thought to represent gastrointestinal stromal tumor (GIST). Subsequent clinical and immunohistochemical evaluation proved the neoplasm to represent metastatic lobular carcinoma. This case illustrates that although c-kit is highly specific and sensitive for GIST, its expression may occur in a variety of other neoplasms, some of which morphologically resemble GIST and may present in the gastrointestinal tract as metastases. Therefore, a review of other c-kit-positive lesions is also highlighted.
Rahman, G A; Johnson, A W
2001-03-01
We report our experience of managing an 18-month-old boy in whom a giant omental cyst of 4.6 kg, which constituted 42% of his pre-operative weight, masqueraded as massive ascites. Pre-operative diagnosis and early surgical intervention were facilitated by inter-disciplinary collaboration, ultrasonography and radiological contrast studies. The differential diagnoses and treatment options of omental and mesenteric cysts are discussed. The importance of ultrasonography as an initial imaging tool for arriving at the correct diagnosis in a child with ascites of obscure aetiology is emphasized.
Light variations of the population II F-type supergiant HD 46703
NASA Technical Reports Server (NTRS)
Bond, H. E.; Carney, B. W.; Grauer, A. D.
1984-01-01
Photometric monitoring has revealed brightness variations of 0.1 m on a time scale of weeks for HD 46703, a metal-deficient F-type field analog of the stars lying above the horizontal branch in globular clusters. It is suggested that HD 46703 belongs to the '89 Her' class of luminous F-type variables. Since HD 46703 is unquestionably a halo object, it is almost certainly a low-mass star. It is suggested that it, and probably the other 89 Her variables, are masquerading as supergiants during their final evolution off the asymptotic giant branch.
Intermittent chronic neutropenia in a patient with familial Mediterranean fever.
Ganiou Tidjani, K; Ailal, F; Najib, J; Bellanné-Chantelot, C; Donadieu, J; Bousfiha, A A
2008-11-01
A 12-year-old daughter of consanguineous Moroccan parents was diagnosed with cyclic neutropenia, based on a combination of recurrent gingivostomatitis, a fluctuating neutrophil count, and several episodes of severe neutropenia. No ELA2 gene mutations were found. At age 19 years she presented with edema of the limbs, proteinuria and renal failure. Renal amyloidosis AA was diagnosed by biopsy. Gene mutations associated with family Mediterranean fever (FMF) were sought, and a homozygous mutation (M694V) was found in the MFEV gene. This is the novel finding of FMF that masqueraded as cyclic neutropenia. (c) 2008 Wiley-Liss, Inc.
An unusual gross appearance of vulval tuberculosis masquerading as tumor.
Arakeri, Surekha U; Sinkar, Prachi
2014-01-01
Tuberculosis of the vulva is very rare. It is found in about 0.2% of the cases of genital tract tuberculosis. It usually presents as small shallow ulcers and multiple sinus tracts or rarely as elephantiasis of vulva. Except for very rare cases of primary tuberculosis in the vulva, it is usually associated with tuberculosis elsewhere in the body leading to secondary tuberculosis. Here, we report a case of secondary vulval tuberculosis which presented as a vulval mass in a 40-year-old female patient. The rarity of this presentation in the female genital tract is emphasized.
The Epistemology of War Gaming
2006-01-01
E G E R E V I E W Insiders have a term for nongames masquerading as games : BOGSAT (“Bunch of Guys Sitting around...context of the game , actual—not simulated—command and control occurs. Thus, knowledge gained from this 1 1 4 N A V A L W A R C O L L E G E R E V I E W T...critic would the out- come of a real battle or campaign. Results of a war game cannot be used to fill in R U B E L 1 1 7 A common reason for mounting a
Gingival squamous cell carcinoma masquerading as an aphthous ulcer
Kumari, Prathypaty Santha; Kumar, Gudi Pavan; Bai, Yendluri Durga; Reddy, Eragam Yella Reddy Balaji Naveen
2013-01-01
Gingival squamous cell carcinoma (GSCC) is an uncommon condition of the oral cavity. It is seldom associated with classic risk factors of oral cancer and shows a predilection for females. It's close clinical resemblances to various lesions of the oral cavity may make it go unnoticed. This may lead to diagnosis at advanced stages and coupled with the proximity to underlying alveolar bone may result in subsequent morbidity and mortality. A case of GSCC camouflaged as an aphthous ulcer in a middle aged woman is presented. The article highlights the importance of early diagnosis resulting in conservative treatment approaches. PMID:24174737
Gastrostomy feeding tube - bolus
... jaw muscles. Feeding Your Child With the Gravity Method Your provider will show you the best way ... the button. Feeding Your Child With the Syringe Method Your provider will teach you the best way ...
MedlinePlus Videos and Cool Tools
... Numbers and Websites Search Share Listen English Español Information about this page Click on the button that ... about drug abuse, addiction, and treatment. Watch Videos Information About Drugs Alcohol Bath Salts Cocaine Heroin Marijuana ...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-01
...; input/output assemblies; electromagnetic interference support walls; bumpers; adhesives; sleeves; rubber... shroud assemblies; mechanism bases; storage; busbars; button dim links; electromagnetic interference fans...
... Submit What's this? Submit Button NCHS Home Viral Hepatitis Recommend on Facebook Tweet Share Compartir Data are for the U.S. Morbidity Number of new hepatitis A cases: 1,239 (2014) Number of new ...
Ways to measure body temperature in the field.
Langer, Franz; Fietz, Joanna
2014-05-01
Body temperature (Tb) represents one of the key parameters in ecophysiological studies with focus on energy saving strategies. In this study we therefore comparatively evaluated the usefulness of two types of temperature-sensitive passive transponders (LifeChips and IPTT-300) and one data logger (iButton, DS1922L) mounted onto a collar to measure Tb in the field. First we tested the accuracy of all three devices in a water bath with water temperature ranging from 0 to 40°C. Second, we evaluated the usefulness of the LifeChips and the modified iButtons for measuring Tb of small heterothermic mammals under field conditions. For this work we subcutaneously implanted 14 male edible dormice (Glis glis) with transponders, and equipped another 14 males with data loggers to simultaneously record Tb and oxygen consumption with a portable oxygen analyzer (Oxbox). In one individual we recorded Tb with both devices and analyzed recorded Tb patterns. LifeChips are able to measure temperature within the smallest range from 25 to 40°C with an accuracy of 0.07±0.12°C. IPTT-300 transponders measured temperature between 10 and 40°C, but accuracy decreased considerably at values below 30°C, with maximal deviations of nearly 7°C. An individual calibration of each transponder is therefore needed, before using it at low Tbs. The accuracy of the data logger was comparatively good (0.12±0.25°C) and stable over the whole temperature range tested (0-40°C). In all three devices, the repeatability of measurements was high. LifeChip transponders as well as modified iButtons measured Tb reliably under field conditions. Simultaneous Tb-recordings in one edible dormouse with an implanted LifeChip and a collar-mounted iButton revealed that values of both measurements were closely correlated. Taken together, we conclude that implanted temperature-sensitive transponders represent an appropriate and largely non-invasive method to measure Tb also under field conditions. Copyright © 2014 Elsevier Ltd. All rights reserved.
... learned that a PHR saves time, energy, and money. And it saved my life! A woman's Facebook ... Doctor’s Visit A Reference Guide Blue Button Resources Mobile PHRs Blog FAQ © 2018 AHIMA, All Rights Reserved | ...
... learned that a PHR saves time, energy, and money. And it saved my life! A woman's Facebook ... Doctor’s Visit A Reference Guide Blue Button Resources Mobile PHRs Blog FAQ © 2018 AHIMA, All Rights Reserved | ...
National Centers for Environmental Prediction
code. Press enter or select the go button to submit request Local forecast by "City, St" City , St Go Search NCEP Go Current Hazards Watches/Warnings Outlooks National Current Conditions
FastStats: Obesity and Overweight
... this? Submit What's this? Submit Button NCHS Home Obesity and Overweight Recommend on Facebook Tweet Share Compartir ... Percent of adults aged 20 and over with obesity: 37.9% (2013-2014) Percent of adults aged ...
... NICHD Research Information Find a Study More Information Pharmacology Condition Information NICHD Research Information Find a Study ... button to look inside the pelvis 4 Pelvic MRI (magnetic resonance imaging) scan, an imaging test that ...
Caregiving for Alzheimer's Disease or Other Dementia
... What's this? Submit Button Caregiving for Person with Alzheimer's Disease or a related Dementia Recommend on Facebook Tweet Share Compartir What is Alzheimer’s Disease? Alzheimer’s disease is the most common form ...
Faststats: Attention Deficit Hyperactivity Disorder (ADHD)
... this? Submit What's this? Submit Button NCHS Home Attention Deficit Hyperactivity Disorder (ADHD)* Recommend on Facebook Tweet ... visits Number of visits to physician offices with attention deficit disorder as the primary diagnosis: 10.9 ...
Tourette Syndrome: Help Stop Bullying
... Submit Button Past Emails Tourette Syndrome: Help Stop Bullying Language: English (US) Español (Spanish) Recommend on Facebook ... you can increase acceptance by helping to stop bullying of children with TS. Bullying doesn’t just ...
Head Lice: Information for Parents
... Address What's this? Submit What's this? Submit Button Information For: Parents Schools Listen to audio/Podcast Related ... General Public. Contact Us Parasites Home Head Lice Information for Parents Language: English (US) Español (Spanish) Recommend ...
Code of Federal Regulations, 2010 CFR
2010-01-01
... exempt from this regulation (§§ 1500.18(a)(9) and 1501.4 below): (a) Balloons; (b) Books and other... clothing and accessories, such as shoe lace holders and buttons; (e) Grooming, feeding, and hygiene...
Research of Medication Use during Pregnancy
... Podcasts and Videos Buttons CDC’s Work Pregnancy Homepage Research Recommend on Facebook Tweet Share Compartir CDC and ... registration. Studies from the Centers for Birth Defects Research and Prevention CDC funds the Centers for Birth ...
FastStats: Anemia or Iron Deficiency
... this? Submit What's this? Submit Button NCHS Home Anemia or Iron Deficiency Recommend on Facebook Tweet Share ... visits Number of visits to emergency departments with anemia as the primary hospital discharge diagnosis: 188,000 ...
FastStats: Self-Inflicted Injury/Suicide
... this? Submit What's this? Submit Button NCHS Home Suicide and Self-Inflicted Injury Recommend on Facebook Tweet ... Tables, table 17 [PDF – 676 KB] Mortality All suicides Number of deaths: 44,193 Deaths per 100, ...
Sudden Infant Death Syndrome (SIDS) and Vaccines
... this? Submit What's this? Submit Button Sudden Infant Death Syndrome (SIDS) Recommend on Facebook Tweet Share Compartir ... an international network of vaccine safety experts. SIDS deaths declined due to recommendations to put infants on ...
36 CFR 1192.127 - Sleeping compartments.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Intercity Rail Cars and Systems § 1192.127 Sleeping compartments. (a) Sleeping compartments required to be... controls, call buttons, electrical outlets, etc.) shall be mounted no more than 48 inches, and no less than...
36 CFR 1192.127 - Sleeping compartments.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Intercity Rail Cars and Systems § 1192.127 Sleeping compartments. (a) Sleeping compartments required to be... controls, call buttons, electrical outlets, etc.) shall be mounted no more than 48 inches, and no less than...
... input class="button submit" name="commit" type="submit" value="Submit" /> Information For… Media Policy ... and Severe Microcephaly Comparison The images are in the public domain and thus free of any copyright restrictions. As a matter of ...
FastStats: Oral and Dental Health
... What's this? Submit Button NCHS Home Oral and Dental Health Recommend on Facebook Tweet Share Compartir Data ... States, 2016, table 60 [PDF – 9.8 MB] Dental visits Percent of children aged 2-17 years ...
Parents of Kids with Infectious Diseases
... news labs links & resources hpv overview why vaccinate posters buttons and banners videos someone you love flu ... such thing as stomach flu pregnancy and flu posters meningitis overview why vaccinate CDC and meningitis Stiletto ...
General Information about MRSA in Healthcare Settings
... this? Submit Button General Information About MRSA in Healthcare Settings Recommend on Facebook Tweet Share Compartir In ... at Risk, and How is MRSA Spread in Healthcare Settings? MRSA is usually spread by direct contact ...
... this? Submit What's this? Submit Button NCHS Home Heart Disease Recommend on Facebook Tweet Share Compartir Data are ... the U.S. Morbidity Number of adults with diagnosed heart disease: 28.1 million Percent of adults with diagnosed ...
36 CFR 1192.127 - Sleeping compartments.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Intercity Rail Cars and Systems § 1192.127 Sleeping compartments. (a) Sleeping compartments required to be... controls, call buttons, electrical outlets, etc.) shall be mounted no more than 48 inches, and no less than...
36 CFR 1192.127 - Sleeping compartments.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Intercity Rail Cars and Systems § 1192.127 Sleeping compartments. (a) Sleeping compartments required to be... controls, call buttons, electrical outlets, etc.) shall be mounted no more than 48 inches, and no less than...
Visual Basic VPython Interface: Charged Particle in a Magnetic Field
NASA Astrophysics Data System (ADS)
Prayaga, Chandra
2006-12-01
A simple Visual Basic (VB) to VPython interface is described and illustrated with the example of a charged particle in a magnetic field. This interface allows data to be passed to Python through a text file read by Python. The first component of the interface is a user-friendly data entry screen designed in VB, in which the user can input values of the charge, mass, initial position and initial velocity of the particle, and the magnetic field. Next, a command button is coded to write these values to a text file. Another command button starts the VPython program, which reads the data from the text file, numerically solves the equation of motion, and provides the 3d graphics animation. Students can use the interface to run the program several times with different data and observe changes in the motion.
Modeling Auditory-Haptic Interface Cues from an Analog Multi-line Telephone
NASA Technical Reports Server (NTRS)
Begault, Durand R.; Anderson, Mark R.; Bittner, Rachael M.
2012-01-01
The Western Electric Company produced a multi-line telephone during the 1940s-1970s using a six-button interface design that provided robust tactile, haptic and auditory cues regarding the "state" of the communication system. This multi-line telephone was used as a model for a trade study comparison of two interfaces: a touchscreen interface (iPad)) versus a pressure-sensitive strain gauge button interface (Phidget USB interface controllers). The experiment and its results are detailed in the authors' AES 133rd convention paper " Multimodal Information Management: Evaluation of Auditory and Haptic Cues for NextGen Communication Dispays". This Engineering Brief describes how the interface logic, visual indications, and auditory cues of the original telephone were synthesized using MAX/MSP, including the logic for line selection, line hold, and priority line activation.
A Single-Channel EOG-Based Speller.
He, Shenghong; Li, Yuanqing
2017-11-01
Electrooculography (EOG) signals, which can be used to infer the intentions of a user based on eye movements, are widely used in human-computer interface (HCI) systems. Most existing EOG-based HCI systems incorporate a limited number of commands because they generally associate different commands with a few different types of eye movements, such as looking up, down, left, or right. This paper presents a novel single-channel EOG-based HCI that allows users to spell asynchronously by only blinking. Forty buttons corresponding to 40 characters displayed to the user via a graphical user interface are intensified in a random order. To select a button, the user must blink his/her eyes in synchrony as the target button is flashed. Two data processing procedures, specifically support vector machine (SVM) classification and waveform detection, are combined to detect eye blinks. During detection, we simultaneously feed the feature vectors extracted from the ongoing EOG signal into the SVM classification and waveform detection modules. Decisions are made based on the results of the SVM classification and waveform detection. Three online experiments were conducted with eight healthy subjects. We achieved an average accuracy of 94.4% and a response time of 4.14 s for selecting a character in synchronous mode, as well as an average accuracy of 93.43% and a false positive rate of 0.03/min in the idle state in asynchronous mode. The experimental results, therefore, demonstrated the effectiveness of this single-channel EOG-based speller.
Dynamic fMRI of a decision-making task
NASA Astrophysics Data System (ADS)
Singh, Manbir; Sungkarat, Witaya
2008-03-01
A novel fMRI technique has been developed to capture the dynamics of the evolution of brain activity during complex tasks such as those designed to evaluate the neural basis of decision-making under different situations. A task called the Iowa Gambling Task was used as an example. Six normal human volunteers were studied. The task was presented inside a 3T MRI and a dynamic fMRI study of the approximately 2s period between the beginning and end of the decision-making period was conducted by employing a series of reference functions, separated by 200 ms, designed to capture activation at different time-points within this period. As decision-making culminates with a button-press, the timing of the button press was chosen as the reference (t=0) and corresponding reference functions were shifted backward in steps of 200ms from this point up to the time when motor activity from the previous button press became predominant. SPM was used to realign, high-pass filter (cutoff 200s), normalize to the Montreal Neurological Institute (MNI) Template using a 12 parameter affine/non-linear transformation, 8mm Gaussian smoothing, and event-related General Linear Model analysis for each of the shifted reference functions. The t-score of each activated voxel was then examined to find its peaking time. A random effect analysis (p<0.05) showed prefrontal, parietal and bi-lateral hippocampal activation peaking at different times during the decision making period in the n=6 group study.
A novel technique for performing a tongue-lip adhesion-the tongue suspension technique.
Mann, Robert J; Neaman, Keith C; Hill, Brian; Bajnrauh, Robert; Martin, Matthew D
2012-01-01
The tongue-lip adhesion has undergone several modifications in an attempt to reduce surgical complications and failure rates. Current techniques rely on the use of a button at the tongue base for suspension, which raises concerns about possible aspiration and interference with oral motor function and bottle-feeding. A new technique for tongue-lip adhesion is proposed that adds a tongue suspension to the standard surgical adhesion. A total of 22 patients with Pierre Robin sequence who received a tongue-lip adhesion via a tongue suspension technique were reviewed. The surgical technique differs from the standard surgical approach by the use of a suture weave across the base of the tongue instead of a standard button to suspend the tongue anteriorly. Average age at the time of tongue-lip adhesion was 13.9 days, with a mean operative time of 88.8 minutes. A marked improvement in postoperative oxygenation was seen in the majority of patients. One dehiscence occurred secondary to a traumatic postoperative extubation, eventually requiring a tracheostomy for subglottic stenosis. A technical innovation for performing a tongue-lip adhesion using a tongue suspension in conjunction with a standard transverse adhesion of the lip is described. The advantage of the tongue-lip adhesion with suspension includes immediate postoperative extubation, as well as removal of concerns regarding button aspiration and possible interference in early developmental oral motor function and bottle-feeding. This technique is reproducible, expanding the craniofacial surgeon's armamentarium for the management of difficult airways in Pierre Robin sequence.
Lim, Chaw Jiang; Basri, Mahiran; Omar, Dzolkhifli; Abdul Rahman, Mohd Basyaruddin; Salleh, Abu Bakar; Raja Abdul Rahman, Raja Noor Zaliha
2013-01-01
Pesticides are developed with carriers to improve their physicochemical properties and, accordingly, the bioefficacy of the applied formulation. For foliar-applied herbicide, generally less than 0.1% of the active ingredient reaching the target site could reduce pesticide performance. Recently, a carrier of nanoemulsion consisting of oil, surfactant and water, with a particle size of less than 200 nm, has been shown to enhance drug permeability for skin penetration in pharmaceutical delivery systems. In the present work, the aim was to formulate a water-soluble herbicide, glyphosate isopropylamine (IPA), using a green nanoemulsion system for a biological activity study against the weeds creeping foxglove, slender button weed and buffalo grass. The nanoemulsion formulations displayed a significantly lower spray deposition on creeping foxglove (2.9-3.5 ng cm(-2) ), slender button weed (2.6-2.9 ng cm(-2) ) and buffalo grass (1.8-2.4 ng cm(-2) ) than Roundup(®) (3.7-5.1 ng cm(-2) ). The visible injury rates of weeds treated with the nanoemulsion formulations were statistically equivalent to those relating to Roundup(®) at 14 days after treatment, with a control range of 86.67-96.67%. It was hypothesised that the significant difference in spray deposition with equal injury rates can be attributed to enhanced bioactivity of the nanoemulsion formulations. This initial discovery could be the platform for developing better penetration of agrochemical formulations in the future. Copyright © 2013 Society of Chemical Industry.
Cho, Chul-Hyun; Jung, Jae-Hoon; Kim, Beom-Soo
2017-05-01
The purpose of this study was to evaluate the radiologic and clinical outcomes of coracoclavicular (CC) stabilization using a suture button device for Neer type IIB lateral clavicle fractures. Eighteen consecutive patients with Neer type IIB fractures were treated with CC stabilization using a TightRope device (Arthrex, Naples, FL, USA). The mean follow-up period was 46.6 months (range, 24-75 months). Radiologic outcomes were assessed using serial plain radiographs. Clinical outcomes were evaluated using the visual analog scale pain score; University of California, Los Angeles score; American Shoulder and Elbow Surgeons score; and subjective shoulder value. Intraoperative and postoperative complications were also evaluated. Of the 18 cases, 17 (94.4%) showed complete bony union. The mean final visual analog scale pain score was 1.1; University of California, Los Angeles score, 31.3; American Shoulder and Elbow Surgeons score, 88.6; and subjective shoulder value, 88.5%. Four complications were observed: (1) intraoperative coracoid process fracture, (2) nonunion, (3) delayed union, and (4) shoulder stiffness. The case with a coracoid process fracture during coracoid tunnel generation was converted to the K-wire tension band technique. CC stabilization using a suture button device for Neer type IIB lateral clavicle fractures yielded satisfactory radiologic and clinical outcomes. The major advantage of this technique is that implant removal is not required. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Malta, Cristiana P; Damasceno, Naiana Nl; Ribeiro, Rosangela A; Silva, Carolina Sf; Devito, Karina L
2016-12-01
The aim of this study was to evaluate the contamination rate of intra and extraoral digital X ray equipment in a dental radiology clinic at a public educational institution. Samples were collected on three different days, at two times in the day: in the morning, before attending patients, and at the end of the day, after appointment hours and before cleaning and disinfection procedures. Samples were collected from the periapical X-ray machine (tube head, positioning device, control panel and activator button), the panoramic X- ray machine (temporal support, bite block, control panel and activator button), the intraoral digital system (sensor), and the digital system computers (keyboard and mouse). The samples were seeded in different culture media, incubated, and colony forming units (CFU/mL) counted. Biochemical tests were performed for suspected colonies of Staphylococcus, Streptococcus and Gramnegative bacilli (GNB). Fungi were visually differentiated into filamentous fungi and yeasts. The results indicated the growth of fungi and Staphylococcus fromall sampling locations. GNB growth was observed from all sites sampled from the intraoral X-ray equipment. On the panoramic unit, GNB growth was observed in samples from activator button, keyboard and mouse. In general, a higher number of CFU/mL was present before use. It can be concluded that more stringent protocols are needed to control infection and prevent X-ray exams from acting as vehicle for cross contamination. Sociedad Argentina de Investigación Odontológica.
NASA Astrophysics Data System (ADS)
Ding, Hanping; Xie, Yuanyuan; Xue, Xingjian
2011-03-01
BaZr0.1Ce0.7Y0.1Yb0.1O3-δ (BZCYYb) exhibits adequate protonic conductivity as well as sufficient chemical and thermal stability over a wide range of SOFC operating conditions, while layered perovskite PrBaCo2O5+δ (PBCO) has advanced electrochemical properties. This research fully takes advantage of these advanced properties and develops a novel protonic ceramic membrane fuel cell (PCMFC) of Ni-BZCYYb|BZCYYb|PBCO. The performance of the button cell was tested under intermediate-temperature range from 600 to 700 °C with humified H2 (∼3% H2O) as fuel and ambient air as oxidant. The results show that the open circuit potential of 0.983 V and the maximal power density of 490 mW cm-2 were achieved at 700 °C. By co-doping barium zirconate-cerate with Y and Yb, the conductivity of electrolyte was significantly improved. The polarization processes of the button cell were characterized using the complicated electrochemical impedance spectroscopy technique. The results indicate that the polarization resistances contributed from both charge migration processes and mass transfer processes increase with decreasing cell voltage loads. However the polarization resistance induced by mass transfer processes is negligible in the studied button cell.
A hypothesis to explain accuracy of wasp resemblances.
Boppré, Michael; Vane-Wright, Richard I; Wickler, Wolfgang
2017-01-01
Mimicry is one of the oldest concepts in biology, but it still presents many puzzles and continues to be widely debated. Simulation of wasps with a yellow-black abdominal pattern by other insects (commonly called "wasp mimicry") is traditionally considered a case of resemblance of unprofitable by profitable prey causing educated predators to avoid models and mimics to the advantage of both (Figure 1a). However, as wasps themselves are predators of insects, wasp mimicry can also be seen as a case of resemblance to one's own potential antagonist. We here propose an additional hypothesis to Batesian and Müllerian mimicry (both typically involving selection by learning vertebrate predators; cf. Table 1) that reflects another possible scenario for the evolution of multifold and in particular very accurate resemblances to wasps: an innate, visual inhibition of aggression among look-alike wasps, based on their social organization and high abundance. We argue that wasp species resembling each other need not only be Müllerian mutualists and that other insects resembling wasps need not only be Batesian mimics, but an innate ability of wasps to recognize each other during hunting is the driver in the evolution of a distinct kind of masquerade, in which model, mimic, and selecting agent belong to one or several species (Figure 1b). Wasp mimics resemble wasps not (only) to be mistaken by educated predators but rather, or in addition, to escape attack from their wasp models. Within a given ecosystem, there will be selection pressures leading to masquerade driven by wasps and/or to mimicry driven by other predators that have to learn to avoid them. Different pressures by guilds of these two types of selective agents could explain the widely differing fidelity with respect to the models in assemblages of yellow jackets and yellow jacket look-alikes.
How to Create a Personal Health Record
... learned that a PHR saves time, energy, and money. And it saved my life! A woman's Facebook ... Doctor’s Visit A Reference Guide Blue Button Resources Mobile PHRs Blog FAQ © 2018 AHIMA, All Rights Reserved | ...
... disease and a combined set for all diseases. Social Determinants of Health Slide Sets County-level data on poverty, income, ... Hepatitis Slideset HIV Slideset STD Slideset Tuberculosis Slideset Social Determinants of Health Slideset Buttons AtlasPlus Application File Formats Help: How ...
FastStats: Exercise or Physical Activity
... What's this? Submit Button NCHS Home Exercise or Physical Activity Recommend on Facebook Tweet Share Compartir Data are ... adults aged 18 and over who met the Physical Activity Guidelines for aerobic physical activity: 51.7% Percent ...
Novel Third-Law Demonstration.
ERIC Educational Resources Information Center
Lonc, William
1995-01-01
Presents an easy method to demonstrate Third-Law interactions using identical button magnets sliding along a smooth (nonmagnetic) knitting needle. Explains the gravitational and magnetic interactions in the case of horizontal and vertical positions of the needle. (JRH)
36 CFR § 1192.127 - Sleeping compartments.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Intercity Rail Cars and Systems § 1192.127 Sleeping compartments. (a) Sleeping compartments required to be... controls, call buttons, electrical outlets, etc.) shall be mounted no more than 48 inches, and no less than...
Teaching Your Child How to Use 911
... people accidentally push the emergency button on their cell phones. Others don't realize that 911 is for ... where you can be reached, such as your cell phone, pager, or work number. In the confusion of ...
Site Map News Organization Search NWS All NOAA Go Local forecast by "City, St" Search by city or zip code. Press enter or select the go button to submit request City, St Go Front Office OWP
Site Map News Organization Search NWS All NOAA Go Local forecast by "City, St" Search by city or zip code. Press enter or select the go button to submit request City, St Go Front Office OWP
Site Map News Organization Search NWS All NOAA Go Local forecast by "City, St" Search by city or zip code. Press enter or select the go button to submit request City, St Go Front Office OWP
Site Map News Organization Search NWS All NOAA Go Local forecast by "City, St" Search by city or zip code. Press enter or select the go button to submit request City, St Go Front Office OWP
Site Map News Organization Search NWS All NOAA Go Local forecast by "City, St" Search by city or zip code. Press enter or select the go button to submit request City, St Go Front Office OWP
... Submit What's this? Submit Button NCHS Home Home Health Care Recommend on Facebook Tweet Share Compartir Data are ... Data Alzheimer’s disease Characteristics and Use of Home Health Care by Men and Women Aged 65 and Over [ ...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-02
..., AC motors, power supplies, heater tubs, LED light assemblies, triple level and push button switches, control panels, printed circuit boards, power cords, wire harnesses, EMI filters, pressure sensors...
Take 3 Steps Toward Preventing Infections During Cancer Treatment
... low white blood cell count (a condition called neutropenia) during your chemotherapy. Click on the appropriate button ... low white blood cell count (a condition called neutropenia) and infections during your chemotherapy. Learn More > Educational ...
Special Supplement: School Library Media Month.
ERIC Educational Resources Information Center
School Library Media Activities Monthly, 1986
1986-01-01
Describes specific activities for promoting the services of the school library during School Library Media Month in April. Illustrations of and instructions for making promotional buttons, bookmarks, book jackets, banners, flags and puzzles are provided. (EM)
Struma Ovarii with Elevated Ca-125 Levels and Ascites Mimicking Advanced Ca Ovary
Sinha, Navin Kumar
2014-01-01
Struma ovarii is uncommon tumor of ovary which can mimic as advanced carcinoma of ovary. Thyroid tissue is relatively frequent constituent of mature ovarian teratoma. Case of struma ovarii masquerading as cancer of ovary in a female aged 63 yrs showing complex large unilateral multilocular adnexal mass with elevated CA 125 (more than 1721 IU/L) and massive ascites mislead treating surgeons for long time. Clinicians were virtually clueless about preoperative diagnosis. Combination of ascites has been seen in one third cases but association with raised CA 125 is rare(only 8-10 cases so far). This case developed hypothyroidism one week after surgery. PMID:24783110
Singh, Rishi P; Steinle, Nathan C; Bedi, Rumneek; Kaiser, Peter; Lowder, Careen Y
2014-01-01
This report presents a case of metastatic carcinoma to the retina. Retrospective chart review and systematic literature review. The patient was a 78-year-old man with history of small-cell lung cancer and with the development of metastatic carcinoma to the retina. The review of this case and previous literature reveals that the presentation of retinal metastases can occasionally be misinterpreted as infectious retinitis, which can delay the diagnosis of the disease. Metastatic carcinoma to the retina is a rare condition, which should be considered in patients who are suspected of having infectious retinopathy and who fail to respond to traditional antimicrobial therapies.
Enterobius vermicularis infestation masquerading as cervical carcinoma: A cytological diagnosis.
Raju, Kalyani; Verappa, Seema; Venkataramappa, Srinivas Murthy
2015-01-01
Although prevalence of Enterobius vermicularis (EV) infestation in Intestines ranges from 35% to 70%, its prevalence in female genital tract is not known despite several incidental findings. Acute inflammatory cells in the background of cervical Pap smear indicate infestation and should not be neglected as contamination. A 40-year-woman presented with white vaginal discharge persistent for past 1 year. Local examination showed hypertrophied cervix with eversion of both lips and hard consistency of the anterior lip of cervix. A clinical diagnosis of cervical carcinoma was made. However, cervical Pap smear indicated EV eggs in an inflammatory background, treatment to which resulted in completely recovery.
Upadhaya, Sunil; Baig, Mohd; Towfiq, Basim; Al Hadidi, Samer
2017-01-01
ABSTRACT Nodular pulmonary amyloidosis is a very rare form of localized amyloidosis involving the lung, with very little known about its nature. It is usually associated with indolent B cell lymphoproliferative disorder and also connective tissue disorders. No definite treatment guideline exists. Many patients respond to chemotherapy with low risk of progression and a ‘wait and watch’ strategy is also considered a valid treatment option. In this report the authors present a case of nodular pulmonary amyloidosis with pulmonary mucosa associated lymphoid tissue (MALT) lymphoma that presented with features of metastatic malignant disease and after definitive diagnosis decided not to undergo treatment. PMID:28808514
Central nervous system filariasis masquerading as a glioma: case report.
Shrivastava, Adesh; Arora, Prateek; Khare, Akriti; Goel, Garima; Kapoor, Neelkamal
2017-09-01
Filariasis, an endemic zoonosis in the Southeast Asia region, has been reported to affect various organs as well as the central nervous system (CNS). Inflammatory reactions mimicking those from neoplastic lesions clinically and radiologically have been reported in the breast and urinary bladder. To date, a CNS manifestation of filarial infestation has been reported in the form of meningoencephalitis. The authors here present an interesting case of a young man presenting in status epilepticus, which on radiological evaluation appeared to be a glioma. However, postoperative histopathological examination changed the provisional diagnosis to a filarial infection of the CNS mimicking a primary CNS neoplasm.
S stars in the Gaia era: stellar parameters and nucleosynthesis
NASA Astrophysics Data System (ADS)
van Eck, Sophie; Karinkuzhi, Drisya; Shetye, Shreeya; Jorissen, Alain; Goriely, Stéphane; Siess, Lionel; Merle, Thibault; Plez, Bertrand
2018-04-01
S stars are s-process and C-enriched (0.5
Far East Scarlet-like Fever Masquerading as Adult-onset Kawasaki Disease
Ocho, Kazuki; Iwamuro, Masaya; Hasegawa, Kou; Hagiya, Hideharu; Rai, Kammei; Yumoto, Tetsuya; Otsuka, Fumio
2017-01-01
A previously healthy 31-year-old man was referred to us with refractory septic shock accompanied by bilateral conjunctival congestion and erythema of his right lower limb. Nine days after admission, he had bilateral desquamation of the fingertips, and his presentation satisfied the criteria for Kawasaki disease. A serological examination was positive for Yersinia pseudotuberculosis, and he was diagnosed with Far East scarlet-like fever (FESLF). Interestingly, his 11-month-old baby boy had similar symptoms around the same time, indicating the intrafamilial transmission of the pathogen. We should consider FESLF when we encounter a familial occurrence of systemic manifestations of Kawasaki disease. PMID:29093407