Sample records for button personal inhalable

  1. An evaluation of total and inhalable samplers for the collection of wood dust in three wood products industries.

    PubMed

    Harper, Martin; Muller, Brian S

    2002-10-01

    In 1998 the American Conference for Governmental Industrial Hygienists (ACGIH) proposed size selective sampling for wood dust based on the inhalable fraction. Thus the proposed threshold limit values (TLVs) require the use of a sampler whose performance matches the inhalable convention. The Institute of Occupational Medicine (IOM) sampler has shown good agreement with the inhalable convention under controlled conditions, and the Button sampler, developed by the University of Cincinnati, has shown reasonable agreement in at least one laboratory study. The Button sampler has not been previously evaluated under wood working conditions, and the IOM has been shown to sample more mass than expected when compared to the standard closed-face cassette, which may be due to the collection of very large particles in wood working environments. Some projectile particles may be > 100 microm aerodynamic diameter and thus outside the range of the convention. Such particles, if present, can bias the estimates of concentration considerably. This study is part of an on-going research focus into selecting the most appropriate inhalable sampler for use in these industries, and to examine the impact of TLV changes. This study compared gravimetric analyses (National Institute of Occupational Safety and Health Method 0500) of side-by-side personal samples using the Button, IOM, and 37 mm closed-face cassette (CFC) under field-use conditions. A total of 51 good sample pairs were collected from three wood products industries involved in the manufacturing of cabinets, furniture, and shutters. Paired t-tests were run on each sample pair using Statistical Package for the Social Sciences (SPSS) version 10. The IOM and the CFC measured statistically different concentrations (p < 0.0005, n = 16). The IOM and Button measured statistically different concentrations (p = 0.020, n = 12). The Button and CFC did not measure statistically different concentrations of wood dust (p = 0.098, n = 23). Sampler ratios for IOM/CFC pairs ranged from 1.19-19 (median 3.35). Sampler ratios for IOM/Button pairs ranged from 0.49-163 (median 3.15). Sampler ratios for CFC/Button pairs ranged from 0.36-27 (median 1.2). In all cases, higher ratios were associated with higher concentrations. The median relative difference between the IOM's and CFC's is in accord with prior field studies in woodworking environments, and, taken together, the data imply a conversion factor greater than the 2.5 normally applied to CFC results to approximate inhalable values, as measured by the IOM. Raising the limit values by approximately 50% appears warranted for this particular situation of inhalable wood dust measured by the IOM. The IOM/Button and CFC/Button ratios were unexpectedly low, which may be due to the exclusion of very large particles, collected by the IOM and CFC samplers. Further work is required to explain these results.

  2. Field comparison of three inhalable samplers (IOM, PGP-GSP 3.5 and Button) for welding fumes.

    PubMed

    Zugasti, Agurtzane; Montes, Natividad; Rojo, José M; Quintana, M José

    2012-02-01

    Inhalable sampler efficiency depends on the aerodynamic size of the airborne particles to be sampled and the wind speed. The aim of this study was to compare the behaviour of three personal inhalable samplers for welding fumes generated by Manual Metal Arc (MMA) and Metal Active Gas (MAG) processes. The selected samplers were the ones available in Spain when the study began: IOM, PGP-GSP 3.5 (GSP) and Button. Sampling was carried out in a welding training center that provided a homogeneous workplace environment. The static sampling assembly used allowed the placement of 12 samplers and 2 cascade impactors simultaneously. 183 samples were collected throughout 2009 and 2010. The range of welding fumes' mass concentrations was from 2 mg m(-3) to 5 mg m(-3). The pooled variation coefficients for the three inhalable samplers were less than or equal to 3.0%. Welding particle size distribution was characterized by a bimodal log-normal distribution, with MMADs of 0.7 μm and 8.2 μm. For these welding aerosols, the Button and the GSP samplers showed a similar performance (P = 0.598). The mean mass concentration ratio was 1.00 ± 0.01. The IOM sampler showed a different performance (P < 0.001). The mean mass concentration ratios were 0.90 ± 0.01 for Button/IOM and 0.92 ± 0.02 for GSP/IOM. This information is useful to consider the measurements accomplished by the IOM, GSP or Button samplers together, in order to assess the exposure at workplaces over time or to study exposure levels in a specific industrial activity, as welding operations.

  3. Performance of personal inhalable aerosol samplers in very slowly moving air when facing the aerosol source.

    PubMed

    Witschger, O; Grinshpun, S A; Fauvel, S; Basso, G

    2004-06-01

    While personal aerosol samplers have been characterized primarily based on wind tunnel tests conducted at relatively high wind speeds, modern indoor occupational environments are usually represented by very slow moving air. Recent surveys suggest that elevated levels of occupational exposure to inhalable airborne particles are typically observed when the worker, operating in the vicinity of the dust source, faces the source. Thus, the first objective of this study was to design and test a new, low cost experimental protocol for measuring the sampling efficiency of personal inhalable aerosol samplers in the vicinity of the aerosol source when the samplers operate in very slowly moving air. In this system, an aerosol generator, which is located in the centre of a room-sized non-ventilated chamber, continuously rotates and omnidirectionally disperses test particles of a specific size. The test and reference samplers are equally distributed around the source at the same distance from the centre and operate in parallel (in most of our experiments, the total number of simultaneously operating samplers was 15). Radial aerosol transport is driven by turbulent diffusion and some natural convection. For each specific particle size and the sampler, the aerosol mass concentration is measured by weighing the collection filter. The second objective was to utilize the new protocol to evaluate three widely used aerosol samplers: the IOM Personal Inhalable Sampler, the Button Personal Inhalable Aerosol Sampler and the 25 mm Millipore filter holder (closed-face C25 cassette). The sampling efficiencies of each instrument were measured with six particle fractions, ranging from 6.9 to 76.9 micro m in their mass median aerodynamic diameter. The Button Sampler efficiency data demonstrated a good agreement with the standard inhalable convention and especially with the low air movement inhalabilty curve. The 25 mm filter holder was found to considerably under-sample the particles larger than 10 micro m; its efficiency did not exceed 7% for particles of 40-100 micro m. The IOM Sampler facing the source was found to over-sample compared with the data obtained previously with a slowly rotating, freely suspended sampler in a low air movement environment. It was also found that the particle wall deposition in the IOM metallic cartridge was rather significant and particle size-dependent. For each sampler (IOM, Button and C25) the precision was characterized through the relative standard deviation (RSD) of the aerosol concentration obtained with identical samplers in a specific experiment. The average RSD was 14% for the IOM Sampler, 11% for the Button Sampler and 35% for the 25 mm filter cassette. A separate set of experiments, performed with the Simplified Torso showed that in very slowly moving air a personal sampler can be adequately evaluated even when it is not attached to a body but freely suspended (confirming the data reported previously).

  4. Field evaluation of personal sampling methods for multiple bioaerosols.

    PubMed

    Wang, Chi-Hsun; Chen, Bean T; Han, Bor-Cheng; Liu, Andrew Chi-Yeu; Hung, Po-Chen; Chen, Chih-Yong; Chao, Hsing Jasmine

    2015-01-01

    Ambient bioaerosols are ubiquitous in the daily environment and can affect health in various ways. However, few studies have been conducted to comprehensively evaluate personal bioaerosol exposure in occupational and indoor environments because of the complex composition of bioaerosols and the lack of standardized sampling/analysis methods. We conducted a study to determine the most efficient collection/analysis method for the personal exposure assessment of multiple bioaerosols. The sampling efficiencies of three filters and four samplers were compared. According to our results, polycarbonate (PC) filters had the highest relative efficiency, particularly for bacteria. Side-by-side sampling was conducted to evaluate the three filter samplers (with PC filters) and the NIOSH Personal Bioaerosol Cyclone Sampler. According to the results, the Button Aerosol Sampler and the IOM Inhalable Dust Sampler had the highest relative efficiencies for fungi and bacteria, followed by the NIOSH sampler. Personal sampling was performed in a pig farm to assess occupational bioaerosol exposure and to evaluate the sampling/analysis methods. The Button and IOM samplers yielded a similar performance for personal bioaerosol sampling at the pig farm. However, the Button sampler is more likely to be clogged at high airborne dust concentrations because of its higher flow rate (4 L/min). Therefore, the IOM sampler is a more appropriate choice for performing personal sampling in environments with high dust levels. In summary, the Button and IOM samplers with PC filters are efficient sampling/analysis methods for the personal exposure assessment of multiple bioaerosols.

  5. Performance study of personal inhalable aerosol samplers at ultra-low wind speeds.

    PubMed

    Sleeth, Darrah K; Vincent, James H

    2012-03-01

    The assessment of personal inhalable aerosol samplers in a controlled laboratory setting has not previously been carried out at the ultra-low wind speed conditions that represent most modern workplaces. There is currently some concern about whether the existing inhalable aerosol convention is appropriate at these low wind speeds and an alternative has been suggested. It was therefore important to assess the performance of the most common personal samplers used to collect the inhalable aerosol fraction, especially those that were designed to match the original curve. The experimental set-up involved use of a hybrid ultra-low speed wind tunnel/calm air chamber and a rotating, heating breathing mannequin to measure the inhalable fraction of aerosol exposure. The samplers that were tested included the Institute of Occupational Medicine (IOM), Button, and GSP inhalable samplers as well as the closed-face cassette sampler that has been (and still is) widely used by occupational hygienists in many countries. The results showed that, down to ∼0.2 m s(-1), the samplers matched the current inhalability criterion relatively well but were significantly greater than this at the lowest wind speed tested. Overall, there was a significant effect of wind speed on sampling efficiency, with lower wind speeds clearly associated with an increase in sampling efficiency.

  6. Foreign object - inhaled

    MedlinePlus

    ... can easily inhale small foods (nuts, seeds, or popcorn) and objects (buttons, beads, or parts of toys) ... foods such as hot dogs, whole grapes, nuts, popcorn, food with bones, or hard candy to children ...

  7. Solid versus Liquid Particle Sampling Efficiency of Three Personal Aerosol Samplers when Facing the Wind

    PubMed Central

    Koehler, Kirsten A.; Anthony, T. Renee; Van Dyke, Michael

    2016-01-01

    The objective of this study was to examine the facing-the-wind sampling efficiency of three personal aerosol samplers as a function of particle phase (solid versus liquid). Samplers examined were the IOM, Button, and a prototype personal high-flow inhalable sampler head (PHISH). The prototype PHISH was designed to interface with the 37-mm closed-face cassette and provide an inhalable sample at 10 l min−1 of flow. Increased flow rate increases the amount of mass collected during a typical work shift and helps to ensure that limits of detection are met, particularly for well-controlled but highly toxic species. Two PHISH prototypes were tested: one with a screened inlet and one with a single-pore open-face inlet. Personal aerosol samplers were tested on a bluff-body disc that was rotated along the facing-the-wind axis to reduce spatiotemporal variability associated with sampling supermicron aerosol in low-velocity wind tunnels. When compared to published data for facing-wind aspiration efficiency for a mouth-breathing mannequin, the IOM oversampled relative to mannequin facing-the-wind aspiration efficiency for all sizes and particle types (solid and liquid). The sampling efficiency of the Button sampler was closer to the mannequin facing-the-wind aspiration efficiency than the IOM for solid particles, but the screened inlet removed most liquid particles, resulting in a large underestimation compared to the mannequin facing-the-wind aspiration efficiency. The open-face PHISH results showed overestimation for solid particles and underestimation for liquid particles when compared to the mannequin facing-the-wind aspiration efficiency. Substantial (and statistically significant) differences in sampling efficiency were observed between liquid and solid particles, particularly for the Button and screened-PHISH, with a majority of aerosol mass depositing on the screened inlets of these samplers. Our results suggest that large droplets have low penetration efficiencies through screened inlets and that particle bounce, for solid particles, is an important determinant of aspiration and sampling efficiencies for samplers with screened inlets. PMID:21965462

  8. Field and wind tunnel comparison of four aerosol samplers using agricultural dusts.

    PubMed

    Reynolds, Stephen J; Nakatsu, Jason; Tillery, Marvin; Keefe, Thomas; Mehaffy, John; Thorne, Peter S; Donham, Kelley; Nonnenmann, Matthew; Golla, Vijay; O'shaughnessy, Patrick

    2009-08-01

    Occupational lung disease is a significant problem among agricultural workers exposed to organic dusts. Measurements of exposure in agricultural environments in the USA have traditionally been conducted using 37-mm closed-face cassettes (CFCs) and respirable Cyclones. Inhalable aerosol samplers offer significant improvement for dose estimation studies to reduce respiratory disease. The goals of this study were to determine correction factors between the inhalable samplers (IOM and Button) and the CFC and Cyclone for dusts sampled in livestock buildings and to determine whether these factors vary among livestock types. Determination of these correction factors will allow comparison between inhalable measurements and historical measurements. Ten sets of samples were collected in swine, chicken, turkey, and dairy facilities in both Colorado and Iowa. Pairs of each sampling device were attached to the front and back of a rotating mannequin. Laboratory studies using a still-air chamber and a wind tunnel provided information regarding the effect of wind speed on sampler performance. Overall, the IOM had the lowest coefficient of variation (best precision) and was least affected by changes in wind speed. The performance of the Button was negatively impacted in poultry environments where larger (feather) particulates clogged the holes in the initial screen. The CFC/IOM ratios are important for comparisons between newer and older studies. Wind speed and dust type were both important factors affecting ratios. Based on the field studies (Table 6), a ratio of 0.56 is suggested as a conversion factor for the CFC/IOM (average for all environments because of no statistical difference). Suggested conversion factors for the Button/IOM are swine (0.57), chicken (0.80), turkey (0.53), and dairy (0.67). Any attempt to apply a conversion factor between the Cyclone and inhalable samplers is not recommended.

  9. Blue Button use by patients to access and share health record information using the Department of Veterans Affairs' online patient portal.

    PubMed

    Turvey, Carolyn; Klein, Dawn; Fix, Gemmae; Hogan, Timothy P; Woods, Susan; Simon, Steven R; Charlton, Mary; Vaughan-Sarrazin, Mary; Zulman, Donna M; Dindo, Lilian; Wakefield, Bonnie; Graham, Gail; Nazi, Kim

    2014-01-01

    The Blue Button feature of online patient portals promotes patient engagement by allowing patients to easily download their personal health information. This study examines the adoption and use of the Blue Button feature in the Department of Veterans Affairs' (VA) personal health record portal, My HealtheVet. An online survey presented to a 4% random sample of My HealtheVet users between March and May 2012. Questions were designed to determine characteristics associated with Blue Button use, perceived value of use, and how Veterans with non-VA providers use the Blue Button to share information with their non-VA providers. Of the survey participants (N=18 398), 33% were current Blue Button users. The most highly endorsed benefit was that it helped patients understand their health history better because all the information was in one place (73%). Twenty-one percent of Blue Button users with a non-VA provider shared their VA health information, and 87% reported that the non-VA provider found the information somewhat or very helpful. Veterans' self-rated computer ability was the strongest factor contributing to both Blue Button use and to sharing information with non-VA providers. When comparing Blue Button users and non-users, barriers to adoption were low awareness of the feature and difficulty using the Blue Button. This study contributes to the understanding of early Blue Button adoption and use of this feature for patient-initiated sharing of health information. Educational efforts are needed to raise awareness of the Blue Button and to address usability issues that hinder adoption. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  10. Button batteries

    MedlinePlus

    Swallowing batteries ... These devices use button batteries: Calculators Cameras Hearing aids Penlights Watches ... If a person puts the battery up their nose and breathes it further in, ... problems Cough Pneumonia (if the battery goes unnoticed) ...

  11. Archeological Survey and Testing in the Holy Cross Historic District, New Orleans, Louisiana. Volume 2

    DTIC Science & Technology

    1992-02-01

    467 Table 4 Personal Items from Shovel Tests, 160R130. SURF SURF SURF N15 N5 NO NO $5 S5 1 2 3 W20 El5 E20 W10 E20 EO Bone button, Type B-5 Ceramic...Table 4 . Personal Items from Shovel Tests, 160R130. S15 S20 S20 S25 S25 S30 S30 S30 S32.5 E5 E35 E20 E50 E25 E50 E35 E20 E35 Bone button, Type B-5...1 1 1 7 1 471 Table 4 Personal Items from Shovel Tests, 160R130. S30 S34 S35 S45 S50 TOTAL El0 E35 E30 E30 E55 Bone button, Type B-5 1 1 Ceramic

  12. The Blue Button Project: Engaging Patients in Healthcare by a Click of a Button.

    PubMed

    Mohsen, Mona Omar; Aziz, Hassan A

    2015-01-01

    The Blue Button project has become a way for many Americans to download their health records by just a click in any way that suits them, such as in print, on a thumb drive, or on their mobile devices and smartphones. Several organizations have developed and applied Blue Buttons on their websites to allow beneficiaries to securely access and view personal medical information and claims. The purpose of this literature review is to highlight the significance of the Blue Button project in the field of health information management. Findings suggest that the project could empower and engage consumers and patients in a healthcare system by allowing access to medical records, thereby promoting better management and overall improvement of their healthcare. To date, the project has gained wide support from insurers, technology companies, and health providers despite the challenges of standardization and interoperability.

  13. The Blue Button Project: Engaging Patients in Healthcare by a Click of a Button

    PubMed Central

    Mohsen, Mona Omar; Aziz, Hassan A.

    2015-01-01

    The Blue Button project has become a way for many Americans to download their health records by just a click in any way that suits them, such as in print, on a thumb drive, or on their mobile devices and smartphones. Several organizations have developed and applied Blue Buttons on their websites to allow beneficiaries to securely access and view personal medical information and claims. The purpose of this literature review is to highlight the significance of the Blue Button project in the field of health information management. Findings suggest that the project could empower and engage consumers and patients in a healthcare system by allowing access to medical records, thereby promoting better management and overall improvement of their healthcare. To date, the project has gained wide support from insurers, technology companies, and health providers despite the challenges of standardization and interoperability. PMID:26755898

  14. Use of the Blue Button Online Tool for Sharing Health Information: Qualitative Interviews With Patients and Providers.

    PubMed

    Klein, Dawn M; Fix, Gemmae M; Hogan, Timothy P; Simon, Steven R; Nazi, Kim M; Turvey, Carolyn L

    2015-08-18

    Information sharing between providers is critical for care coordination, especially in health systems such as the United States Department of Veterans Affairs (VA), where many patients also receive care from other health care organizations. Patients can facilitate this sharing by using the Blue Button, an online tool that promotes patients' ability to view, print, and download their health records. The aim of this study was to characterize (1) patients' use of Blue Button, an online information-sharing tool in VA's patient portal, My HealtheVet, (2) information-sharing practices between VA and non-VA providers, and (3) how providers and patients use a printed Blue Button report during a clinical visit. Semistructured qualitative interviews were conducted with 34 VA patients, 10 VA providers, and 9 non-VA providers. Interviews focused on patients' use of Blue Button, information-sharing practices between VA and non-VA providers, and how patients and providers use a printed Blue Button report during a clinical visit. Qualitative themes were identified through iterative rounds of coding starting with an a priori schema based on technology adoption theory. Information sharing between VA and non-VA providers relied primarily on the patient. Patients most commonly used Blue Button to access and share VA laboratory results. Providers recognized the need for improved information sharing, valued the Blue Button printout, and expressed interest in a way to share information electronically across settings. Consumer-oriented technologies such as Blue Button can facilitate patients sharing health information with providers in other health care systems; however, more education is needed to inform patients of this use to facilitate care coordination. Additional research is needed to explore how personal health record documents, such as Blue Button reports, can be easily shared and incorporated into the clinical workflow of providers.

  15. Modification of Shirt Buttons for Retrospective Radiation Dosimetry after a Radiological Event

    PubMed Central

    Marino, Stephen A.; Johnson, Gary W.; Schiff, Peter B.; Brenner, David J.

    2010-01-01

    Preliminary results are presented for a personal radiation dosimeter in the form of a clothing button to provide gamma-ray dose estimation for clinically significant external radiation exposures to the general public due to a radiological incident, such as a Radiological Dispersal Device. Rods of thermoluminescent material (LiF:Mg,Ti and LiF:Mg,Cu,P) were encapsulated in plastic “buttons”, attached to shirts, and subjected to three cycles of home or commercial laundering or dry cleaning, including ironing or pressing. The buttons were subsequently exposed to doses of 137Cs gamma rays ranging from 0.75 to 8.2 Gy. The rods were removed from the buttons and their light output compared to their responses when bare or to the responses of a set of calibration rods of the same type and from the same manufacturer. In all three of the comparisons for LiF:Mg,Ti rods the relative responses of the rods in buttons changed by 2-6% relative to the same rods before cleaning. In both comparisons for LiF:Mg,Cu,P rods, the response of laundered rods was 1-3% lower than for the same rods before cleaning. Both these materials are potential candidates for button dosimeters. PMID:21451325

  16. Use of the Blue Button Online Tool for Sharing Health Information: Qualitative Interviews With Patients and Providers

    PubMed Central

    Fix, Gemmae M; Hogan, Timothy P; Simon, Steven R; Nazi, Kim M; Turvey, Carolyn L

    2015-01-01

    Background Information sharing between providers is critical for care coordination, especially in health systems such as the United States Department of Veterans Affairs (VA), where many patients also receive care from other health care organizations. Patients can facilitate this sharing by using the Blue Button, an online tool that promotes patients’ ability to view, print, and download their health records. Objective The aim of this study was to characterize (1) patients’ use of Blue Button, an online information-sharing tool in VA’s patient portal, My HealtheVet, (2) information-sharing practices between VA and non-VA providers, and (3) how providers and patients use a printed Blue Button report during a clinical visit. Methods Semistructured qualitative interviews were conducted with 34 VA patients, 10 VA providers, and 9 non-VA providers. Interviews focused on patients’ use of Blue Button, information-sharing practices between VA and non-VA providers, and how patients and providers use a printed Blue Button report during a clinical visit. Qualitative themes were identified through iterative rounds of coding starting with an a priori schema based on technology adoption theory. Results Information sharing between VA and non-VA providers relied primarily on the patient. Patients most commonly used Blue Button to access and share VA laboratory results. Providers recognized the need for improved information sharing, valued the Blue Button printout, and expressed interest in a way to share information electronically across settings. Conclusions Consumer-oriented technologies such as Blue Button can facilitate patients sharing health information with providers in other health care systems; however, more education is needed to inform patients of this use to facilitate care coordination. Additional research is needed to explore how personal health record documents, such as Blue Button reports, can be easily shared and incorporated into the clinical workflow of providers. PMID:26286139

  17. AUTOMATIC HAND COUNTER

    DOEpatents

    Mann J.R.; Wainwright, A.E.

    1963-06-11

    An automatic, personnel-operated, alpha-particle hand monitor is described which functions as a qualitative instrument to indicate to the person using it whether his hands are cold'' or hot.'' The monitor is activated by a push button and includes several capacitor-triggered thyratron tubes. Upon release of the push button, the monitor starts the counting of the radiation present on the hands of the person. If the count of the radiation exceeds a predetermined level within a predetermined time, then a capacitor will trigger a first thyratron tube to light a hot'' lamp. If, however, the count is below such level during this time period, another capacitor will fire a second thyratron to light a safe'' lamp. (AEC)

  18. The floor effect: impoverished spatial memory for elevator buttons.

    PubMed

    Vendetti, Michael; Castel, Alan D; Holyoak, Keith J

    2013-05-01

    People typically remember objects to which they have frequently been exposed, suggesting that memory is a by-product of perception. However, prior research has shown that people have exceptionally poor memory for the features of some objects (e.g., coins) to which they have been exposed over the course of many years. Here, we examined how people remember the spatial layout of the buttons on a frequently used elevator panel, to determine whether physical interaction (rather than simple exposure) would ensure the incidental encoding of spatial information. Participants who worked in an eight-story office building displayed very poor recall for the elevator panel but above-chance performance on a recognition test. Performance was related to how often and how recently the person had used the elevator. In contrast to their poor memory for the spatial layout of the elevator buttons, most people readily recalled small distinctive graffiti on the elevator walls. In a more implicit test, the majority were able to locate their office floor and the eighth floor button when asked to point toward these buttons when in the actual elevator, with the button labels covered. However, identification was very poor for other floors (including the first floor), suggesting that even frequent interaction with information does not always lead to accurate spatial memory. These findings have implications for understanding the complex relationships among attention, expertise, and memory.

  19. Inhalant Use, Inhalant-Use Disorders, and Antisocial Behavior: Findings From the National Epidemiologic Survey on Alcohol and Related Conditions (NESARC)*

    PubMed Central

    Howard, Matthew O.; Perron, Brian E.; Vaughn, Michael G.; Bender, Kimberly A.; Garland, Eric

    2010-01-01

    Objective: Few studies have explored the topography of antisocial behavior in a nationally representative sample of inhalant users. We examined (a) the lifetime prevalence of 20 childhood and adult antisocial behaviors in inhalant users with inhalant-use disorders (IUD+) and without IUDs (IUD−); (b) the nature and strength of associations between inhalant use, IUDs, and specific antisocial behaviors in multi-variate analyses; and (c) the relationships between inhalant use, IUDs, and antisocial behaviors in a national sample of adults with antisocial personality disorder. Method: The National Epidemiologic Survey on Alcohol and Related Conditions was a multistage national survey of 43,093 U.S. residents. Respondents completed a structured psychiatric interview. Results: IUD+ and IUD− respondents were significantly younger and more likely to be unemployed, to be male, to have never married, and to report family and personal histories of alcohol and drug problems than inhalant nonusers. Family histories of alcohol problems and personal histories of drug problems were significantly more prevalent among IUD+ respondents, compared with IUD− respondents. In bivariate analyses, IUD+ and IUD− respondents evidenced significantly higher lifetime levels of all childhood and adult antisocial behaviors than inhalant nonusers. IUD+ respondents were significantly more likely than their IUD− counterparts to report bullying behavior, starting physical fights, using dangerous weapons, physical cruelty to people, staying out all night without permission, running away, and frequent truancy in childhood, as well as greater deceitfulness, impulsivity, irritability/aggressiveness, recklessness, and irresponsibility in adulthood. Multivari-ate analyses indicated that IUD+ respondents had a significantly elevated risk for childhood and adult antisocial behaviors, compared with inhalant nonusers, with the strongest effects for using dangerous weapons, physical cruelty to animals, and physical cruelty to people. Similarly, IUD+ respondents differed significantly from their IUD− counterparts primarily across measures of interpersonal violence. Among persons with antisocial personality disorder, inhalant use and IUDs were associated with greater antisocial behavior, albeit with fewer and weaker effects. Conclusions: Respondents with IUDs had pervasively elevated levels of antisocial conduct, including diverse forms of early-onset and inter-personally violent behavior. PMID:20230717

  20. Response-Related Potentials during Semantic Priming: The Effect of a Speeded Button Response Task on ERPs

    PubMed Central

    van Vliet, Marijn; Manyakov, Nikolay V.; Storms, Gert; Fias, Wim; Wiersema, Jan R.; Van Hulle, Marc M.

    2014-01-01

    This study examines the influence of a button response task on the event-related potential (ERP) in a semantic priming experiment. Of particular interest is the N400 component. In many semantic priming studies, subjects are asked to respond to a stimulus as fast and accurately as possible by pressing a button. Response time (RT) is recorded in parallel with an electroencephalogram (EEG) for ERP analysis. In this case, the response occurs in the time window used for ERP analysis and response-related components may overlap with stimulus-locked ones such as the N400. This has led to a recommendation against such a design, although the issue has not been explored in depth. Since studies keep being published that disregard this issue, a more detailed examination of influence of response-related potentials on the ERP is needed. Two experiments were performed in which subjects pressed one of two buttons with their dominant hand in response to word-pairs with varying association strength (AS), indicating a personal judgement of association between the two words. In the first experiment, subjects were instructed to respond as fast and accurately as possible. In the second experiment, subjects delayed their button response to enforce a one second interval between the onset of the target word and the button response. Results show that in the first experiment a P3 component and motor-related potentials (MRPs) overlap with the N400 component, which can cause a misinterpretation of the latter. In order to study the N400 component, the button response should be delayed to avoid contamination of the ERP with response-related components. PMID:24516556

  1. Soft and wet actuator developed with responsible high-strength gels

    NASA Astrophysics Data System (ADS)

    Harada, S.; Hidema, R.; Furukawa, H.

    2012-04-01

    Novel high-strength gels, named double network gels (DN gels), show a smart response to altering external electric field. It was reported that a plate shape of the DN gel bends toward a positive electrode direction when a static (DC) electric field is applied. Based on this previous result, it has been tried to develop a novel soft and wet actuator, which will be used as an automatically bulging button for cellar phones, or similar small devices. First, a bending experiment of a hung plate-shape DN gel was done, and its electric field response was confirmed. Second, the response of a lying plate-shape DN gels was confirmed in order to check the bulging phenomena. The edge of three plate-shape gels that was arranged radially on a plane surface was lifted 2mm by applying DC 8V. This system is a first step to make a gels button. However the critical problem is that electrolysis occurs simultaneously under electric field. Then, the water sweep out from gels, and gels is shrinking; They cause the separation between aluminum foil working as electrode and gels. That is why, a flexible electrode should be made by gels completely attached to the gels. As a third step, a push button is tried to make by a shape memory gels (SMG). The Young's modulus of the SMG is dramatically changed by temperature. This change in the modulus is applied to control the input-acceptable state and input-not-acceptable states of the button. A novel push button is proposed as a trial, and its user-friendliness is checked by changing the size of the button. The button is deformed by pushing and is back to original shape due to the property of shape memory. We believe the mechanism of this button will be applied to develop new devices especially for visually impaired persons.

  2. Inhalant use, inhalant-use disorders, and antisocial behavior: findings from the National Epidemiologic Survey on Alcohol and Related Conditions (NESARC).

    PubMed

    Howard, Matthew O; Perron, Brian E; Vaughn, Michael G; Bender, Kimberly A; Garland, Eric

    2010-03-01

    Few studies have explored the topography of antisocial behavior in a nationally representative sample of inhalant users. We examined (a) the lifetime prevalence of 20 childhood and adult antisocial behaviors in inhalant users with inhalant-use disorders (IUD+) and without IUDs (IUD-); (b) the nature and strength of associations between inhalant use, IUDs, and specific antisocial behaviors in multivariate analyses; and (c) the relationships between inhalant use, IUDs, and antisocial behaviors in a national sample of adults with antisocial personality disorder. The National Epidemiologic Survey on Alcohol and Related Conditions was a multistage national survey of 43,093 U.S. residents. Respondents completed a structured psychiatric interview. IUD+ and IUD- respondents were significantly younger and more likely to be unemployed, to be male, to have never married, and to report family and personal histories of alcohol and drug problems than inhalant nonusers. Family histories of alcohol problems and personal histories of drug problems were significantly more prevalent among IUD+ respondents, compared with IUD- respondents. In bivariate analyses, IUD+ and IUD- respondents evidenced significantly higher lifetime levels of all childhood and adult antisocial behaviors than inhalant nonusers. IUD+ respondents were significantly more likely than their IUD- counterparts to report bullying behavior, starting physical fights, using dangerous weapons, physical cruelty to people, staying out all night without permission, running away, and frequent truancy in childhood, as well as greater deceitfulness, impulsivity, irritability/aggressiveness, recklessness, and irresponsibility in adulthood. Multivariate analyses indicated that IUD+ respondents had a significantly elevated risk for childhood and adult antisocial behaviors, compared with inhalant nonusers, with the strongest effects for using dangerous weapons, physical cruelty to animals, and physical cruelty to people. Similarly, IUD+ respondents differed significantly from their IUD- counterparts primarily across measures of interpersonal violence. Among persons with antisocial personality disorder, inhalant use and IUDs were associated with greater antisocial behavior, albeit with fewer and weaker effects. Respondents with IUDs had pervasively elevated levels of antisocial conduct, including diverse forms of early-onset and interpersonally violent behavior.

  3. Mercuric oxide poisoning

    MedlinePlus

    Mercuric oxide may be found in some: Button batteries (batteries containing mercury are no longer sold in the ... long-term injury Any person who swallowed a battery will need immediate x-rays to make sure ...

  4. Caregiving for Alzheimer's Disease or Other Dementia

    MedlinePlus

    ... What's this? Submit Button Caregiving for Person with Alzheimer's Disease or a related Dementia Recommend on Facebook Tweet Share Compartir What is Alzheimer’s Disease? Alzheimer’s disease is the most common form ...

  5. Personal Emergency Response Systems--Communication Technology Aids Elderly and Their Families.

    ERIC Educational Resources Information Center

    Dibner, Andrew S.

    Personal response systems (PRS) bring immediate help to aged and disabled persons at home at the touch of a button. The PRS user wears a tiny radio transmitter as a pendant or a bracelet and can send a telephone signal from any part of the home to a 24-hour emergency center when help is needed. This study examined research on the Lifeline system,…

  6. How to Create a Personal Health Record

    MedlinePlus

    ... learned that a PHR saves time, energy, and money. And it saved my life! A woman's Facebook ... Doctor’s Visit A Reference Guide Blue Button Resources Mobile PHRs Blog FAQ © 2018 AHIMA, All Rights Reserved | ...

  7. A cross-sectional questionnaire study of the rules governing pupils' carriage of inhalers for asthma treatment in secondary schools in North East England.

    PubMed

    Funston, Wendy; Howard, Simon J

    2016-01-01

    Objectives. The primary objective of this study was to assess the rules governing secondary school pupils' carriage of inhalers for emergency treatment of asthma in the North East of England. Design. This study was based upon a postal questionnaire survey. Setting. The setting for this study was mainstream free-to-attend secondary schools which admit 16 year old pupils within the 12 Local Authority areas which make up the North East of England. Participants. All 153 schools meeting the inclusion criteria were invited to participate in the study, of which 106 (69%) took part. Main Outcome Measures. Our three main outcome measures were: whether pupils are permitted to carry inhalers on their person while at school; whether advance permission is required for pupils to carry inhalers, and from whom; and whether the school has an emergency 'standby' salbutamol inhaler for use in asthma emergencies, as permitted since October 2014 under recent amendments to The Human Medicines Regulations 2012. Results. Of 98 schools submitting valid responses to the question, 99% (n = 97) permitted pupils to carry inhalers on their person while at school; the remaining school stored pupils' inhalers in a central location within the school. A total of 22% of included schools (n = 22) required parental permission before pupils were permitted to carry inhalers. Of 102 schools submitting valid responses to the question, 44% (n = 45) had purchased a 'standby' salbutamol inhaler for use in asthma emergencies. Conclusions. Most secondary schools in North East England permit pupils to carry inhalers on their person. The requirement in a minority of schools for parental permission to be given possibly contravenes the standard ethical practices in clinical medicine for children of this age. Only a minority of schools hold a 'standby' salbutamol inhaler for use in asthma emergencies. Wider availability may improve outcomes for asthma emergencies occurring in schools.

  8. eButton: A Wearable Computer for Health Monitoring and Personal Assistance

    PubMed Central

    Sun, Mingui; Burke, Lora E.; Mao, Zhi-Hong; Chen, Yiran; Chen, Hsin-Chen; Bai, Yicheng; Li, Yuecheng; Li, Chengliu; Jia, Wenyan

    2014-01-01

    Recent advances in mobile devices have made profound changes in people's daily lives. In particular, the impact of easy access of information by the smartphone has been tremendous. However, the impact of mobile devices on healthcare has been limited. Diagnosis and treatment of diseases are still initiated by occurrences of symptoms, and technologies and devices that emphasize on disease prevention and early detection outside hospitals are under-developed. Besides healthcare, mobile devices have not yet been designed to fully benefit people with special needs, such as the elderly and those suffering from certain disabilities, such blindness. In this paper, an overview of our research on a new wearable computer called eButton is presented. The concepts of its design and electronic implementation are described. Several applications of the eButton are described, including evaluating diet and physical activity, studying sedentary behavior, assisting the blind and visually impaired people, and monitoring older adults suffering from dementia. PMID:25340176

  9. Improved Tensile Adhesion Specimens for High Strength Epoxy Systems in Aerospace Applications

    NASA Technical Reports Server (NTRS)

    Haddock, M. Reed; McLennan, Michael L.

    2000-01-01

    An improved tensile adhesion button has been designed and tested that results in higher measured tensile adhesion strength while providing increased capability for testing high strength epoxy adhesive systems. The best attributes of two well-established tensile button designs were combined and refined into an optimized tensile button. The most significant design change to the tensile button was to improve alignment of the bonded tensile button specimens during tensile testing by changing the interface between the tensile button and the tensile test machine. The established or old button design uses a test fixture that pulls from a grooved annulus or anvil head while the new button design pulls from a threaded hole in the centerline of the button. Finite element (FE) analysis showed that asymmetric loading of the established anvil head tensile button significantly increases the stress concentration in the adhesive, causing failure at lower tensile test loads. The new tensile button was designed to eliminate asymmetric loading and eliminate misalignment sensitivity. Enhanced alignment resulted in improved tensile adhesion strength measurement up to 13.8 MPa (2000psi) over the established button design. Another design change increased the capability of the button by increasing the threaded hole diameter allowing it to test high strength epoxy systems up to 85 MPa(less than 12,000 psi). The improved tensile button can be used in button- to-button or button-to-panel configurations.

  10. Translations on Telecommunications Policy, Research and Development. Number 4

    DTIC Science & Technology

    1977-06-14

    will include an abbreviated dial service, where one, two or possibly three digits only need be dialled for commonly-used numbers. Push-button...in person at the post offices. [Text] [Havana JUVENTUD REBELDE in Spanish 14 Apr 77 p 2] 7717 CSO: 3010 26 INTER-ARAB AFFAIRS BRIEFS SUDANESE

  11. Real-time PCR detection of toxigenic Fusarium in airborne and settled grain dust and associations with trichothecene mycotoxins.

    PubMed

    Halstensen, Anne Straumfors; Nordby, Karl-Christian; Eduard, Wijnand; Klemsdal, Sonja Sletner

    2006-12-01

    Inhalation of immunomodulating mycotoxins produced by Fusarium spp. that are commonly found in grain dust may imply health risks for grain farmers. Airborne Fusarium and mycotoxin exposure levels are mainly unknown due to difficulties in identifying Fusarium and mycotoxins in personal aerosol samples. We used a novel real-time PCR method to quantify the fungal trichodiene synthase gene (tri5) and DNA specific to F. langsethiae and F. avenaceum in airborne and settled grain dust, determined the personal inhalant exposure level to toxigenic Fusarium during various activities, and evaluated whether quantitative measurements of Fusarium-DNA could predict trichothecene levels in grain dust. Airborne Fusarium-DNA was detected in personal samples even from short tasks (10-60 min). The median Fusarium-DNA level was significantly higher in settled than in airborne grain dust (p < 0.001), and only the F. langsethiae-DNA levels correlated significantly in settled and airborne dust (r(s) = 0.20, p = 0.003). Both F. langsethiae-DNA and tri5-DNA were associated with HT-2 and T-2 toxins (r(s) = 0.24-0.71, p < 0.05 to p < 00.01) in settled dust, and could thus be suitable as indicators for HT-2 and T-2. The median personal inhalant exposure to specific toxigenic Fusarium spp. was less than 1 genome m(-3), but the exposure ranged from 0-10(5) genomes m(-3). This study is the first to apply real-time PCR on personal samples of inhalable grain dust for the quantification of tri5 and species-specific Fusarium-DNA, which may have potential for risk assessments of inhaled trichothecenes.

  12. Operant Conditioning in Older Adults with Alzheimer's Disease

    ERIC Educational Resources Information Center

    Spira, Adam P.; Edelstein, Barry A.

    2007-01-01

    Behavioral interventions based on operant principles are commonly attempted to manage agitation in older adults with dementia. The extent to which operant conditioning can occur in persons with particular dementias, however, is unclear. The present study involved use of a button-pressing task to evaluate the sensitivity of the responding of older…

  13. Typewriter Modifications for Persons Who Are High-Level Quadriplegics.

    ERIC Educational Resources Information Center

    O'Reagan, James R.; And Others

    Standard, common electric typewriters are not completely suited to the needs of a high-level quadriplegic typing with a mouthstick. Experiences show that for complete control of a typewriter a mouthstick user needs the combined features of one-button correction, electric forward and reverse indexing, and easy character viewing. To modify a…

  14. Personal inhalation exposure to polycyclic aromatic hydrocarbons and their nitro-derivatives in rural residents in northern Thailand.

    PubMed

    Orakij, Walaiporn; Chetiyanukornkul, Thaneeya; Chuesaard, Thanyarat; Kaganoi, Yuichi; Uozaki, Waka; Homma, Chiharu; Boongla, Yaowatat; Tang, Ning; Hayakawa, Kazuichi; Toriba, Akira

    2017-09-18

    A personal inhalation exposure and cancer risk assessment of rural residents in Lampang, Thailand, was conducted for the first time. This highlighted important factors that may be associated with the highest areal incidence of lung cancer. Personal exposure of rural residents to polycyclic aromatic hydrocarbons (PAHs) and their nitro-derivatives (NPAHs) through inhalation of fine particulate matter (PM 2.5 ) was investigated in addition to stationary air sampling in an urban area. The personal exposure of the subjects to PM 2.5 ranged from 44.4 to 316 μg/m 3 , and the concentrations of PAHs (4.2-224 ng/m 3 ) and NPAHs (120-1449 pg/m 3 ) were higher than those at the urban site, indicating that personal exposure was affected by microenvironments through individual activities. The smoking behaviors of the rural residents barely affected their exposure to PAHs and NPAHs compared to other sources. The most important factor concerning the exposure of rural populations to PAHs was cooking activity, especially the use of charcoal open fires. The emission sources for rural residents and urban air were evaluated using diagnostic ratios, 1-nitropyrene/pyrene, and benzo[a]pyrene/benzo[ghi]perylene. Their analyses showed a significant contribution to emission from residents' personal activities in addition to the atmospheric environment. Furthermore, the personal inhalation cancer risks for all rural subjects exceeded the USEPA guideline value, suggesting that the residents have a potentially increased cancer risk. The use of open fires showed the highest cancer risk. A reduction in exposure to air pollutants for the residents could potentially be achieved by using clean fuel such as liquid petroleum gas or electricity for daily cooking.

  15. The Role of Inhaled Loxapine in the Treatment of Acute Agitation in Patients with Psychiatric Disorders: A Clinical Review.

    PubMed

    de Berardis, Domenico; Fornaro, Michele; Orsolini, Laura; Iasevoli, Felice; Tomasetti, Carmine; de Bartolomeis, Andrea; Serroni, Nicola; Valchera, Alessandro; Carano, Alessandro; Vellante, Federica; Marini, Stefano; Piersanti, Monica; Perna, Giampaolo; Martinotti, Giovanni; Di Giannantonio, Massimo

    2017-02-08

    Loxapine is a first generation antipsychotic, belonging to the dibenzoxazepine class. Recently, loxapine has been reformulated at a lower dose, producing an inhaled powder that can be directly administered to the lungs to treat the agitation associated with psychiatric disorders, such as schizophrenia and bipolar disorder. Thus, the aim of this narrative and clinical mini-review was to evaluate the efficacy and tolerability of inhaled loxapine in the treatment of acute agitation in patients with psychiatric disorders. The efficacy of inhaled loxapine has been evaluated in one Phase II trial on patients with schizophrenia, and in two Phase III trials in patients with schizophrenia and bipolar disorder. Moreover, there are two published case series on patients with borderline personality disorder and dual diagnosis patients. Inhaled loxapine has proven to be effective and generally well tolerated when administered to agitated patients with schizophrenia and bipolar disorder. Two case series have suggested that inhaled loxapine may also be useful to treat agitation in patients with borderline personality disorder and with dual diagnosis, but further studies are needed to clarify this point. However, the administration of inhaled loxapine requires at least some kind of patient collaboration, and is not recommended in the treatment of severe agitation in totally uncooperative patients. Moreover, the drug-related risk of bronchospasm must always be kept in mind when planning to use inhaled loxapine, leading to a careful patient assessment prior to, and after, administration. Also, the higher costs of inhaled loxapine, when compared to oral and intramuscular medications, should be taken into account when selecting it for the treatment of agitation.

  16. Social Media in a Content Course for the Digital Natives

    ERIC Educational Resources Information Center

    Lie, Anita

    2013-01-01

    Digital technologies and the Internet have revolutionized the way people gather information and acquire new knowledge. With a click of a button or a touch on the screen, any person who is wired to the internet can access a wealth of information, ranging from books, poems, articles, graphics, animations and so much more. It is imperative that…

  17. 77 FR 33737 - Announcement of Requirements and Registration for “Blue Button Mash Up Challenge”

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-07

    ... patient engagement rates. Entrants will therefore have to demonstrate a partnership with a personal health.... (4) May not be a Federal entity or Federal employee acting within the scope of their employment. (5) Shall not be an HHS employee working on their applications or submissions during assigned duty hours. (6...

  18. Evaluation of exposure scenarios on intentional microbiological contamination in a drinking water distribution network.

    PubMed

    Schijven, Jack; Forêt, Jean Marie; Chardon, Jurgen; Teunis, Peter; Bouwknegt, Martijn; Tangena, Ben

    2016-06-01

    Drinking water distribution networks are vulnerable to accidental or intentional contamination events. The objective of this study was to investigate the effects of seeding duration and concentration, exposure pathway (ingestion via drinking of water and tooth brushing and inhalation by taking a shower) and pathogen infectivity on exposure and infection risk in the case of an intentional pathogenic contamination in a drinking water distribution network. Seeding of a pathogen for 10 min and 120 min, and subsequent spreading through a drinking water distribution network were simulated. For exposure via drinking, actual data on drinking events and volumes were used. Ingestion of a small volume of water by tooth brushing twice a day by every person in the network was assumed. Inhalation of contaminated aerosol droplets took place when taking a shower. Infection risks were estimated for pathogens with low (r = 0.0001) and high (r = 0.1) infectivity. In the served population (48 000 persons) and within 24 h, about 1400 persons were exposed to the pathogen by ingestion of water in the 10-min seeding scenario and about 3400 persons in the 120-min scenario. The numbers of exposed persons via tooth brushing were about the same as via drinking of water. Showering caused (inhalation) exposure in about 450 persons in the 10-min scenario and about 1500 in the 120-min scenario. Regardless of pathogen infectivity, if the seeding concentration is 10(6) pathogens per litre or more, infection risks are close to one. Exposure by taking a shower is of relevance if the pathogen is highly infectious via inhalation. A longer duration of the seeding of a pathogen increases the probability of exposure. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Diagnosing Tic Disorders

    MedlinePlus

    ... span class="tp-sr-only">Submit Button Submit Button Orange Button Solar Data Exchange | Energy Analysis | NREL

    Science.gov Websites

    Orange Button Solar Data Exchange Orange Button Solar Data Exchange The new Orange Button Solar Data Exchange tool serves as an online resource for the solar industry to share, sell, or retrieve solar data and connect with colleagues. Screenshot image of Orange Button data website home page. The

  1. LOW-DOSE AIRBORNE ENDOTOXIN EXPOSURE ENHANCES BRONCHIAL RESPONSIVENESS TO INHALED ALLERGEN IN ATOPIC ASTHMATICS

    EPA Science Inventory

    Endotoxin exposure has been associated with both protection against development of TH2-immune responses during childhood and exacerbation of asthma in persons who already have allergic airway inflammation.1 Occupational and experimental inhalation exposures to endotoxin have been...

  2. Tourette Syndrome (TS): Risk Factors and Causes

    MedlinePlus

    ... span class="tp-sr-only">Submit Button Submit Button [Did the patients with chronic obstructive pulmonary disease in Primary Care center Anton de Borja correctly utilize inhalers?].

    PubMed

    Represas-Carrera, Francisco Jesús

    2015-01-01

    To determine the percentage of patients with Pulmonary Obstructive Chronic Disease who doing of incorrect form the inhaler technique. Descriptive transversal study made in the Primary Care Center "Antón de Borja" of Rubi (in Barcelona) during the period between May and December 2013, where it was studied a representative sample of 200 patients. To assess the inhaler technique was performed a personal interview with the patient in which it was requested him to carry out a demonstration of how he was using his inhaler regularly evaluating his inhaler technique by means of the regulations established by Spanish Society of Pneumology and Thoracic Surgery. 43% of the patients carry out inhaler technique incorrectly. The percentage of inadequate use of inhalers of dry powder was 26%, of the pressurized cartridge 38% and the inhaler chamber 10%. 82% of patients ≥ 65 years who have prescribed a pressurized inhaler cartridge do not perform accompanied by an inhaler chamber. A high percentage of patients do not correctly carry out inhaler technique, pointing the rare use made of the inhaler chamber despite its proven efficacy and the high number of patients with pressurized inhaler cartridge. These results reflect the need for the implementation of an educational program in our Primary Care Center to teach patients to use inhaler devices. Copyright © 2014 Elsevier España, S.L.U. All rights reserved.

  3. Hand-Held Keyboard

    NASA Technical Reports Server (NTRS)

    1994-01-01

    The Data Egg, a prototype chord key-based data entry device, can be used autonomously or as an auxiliary keyboard with a personal computer. Data is entered by pressing combinations of seven buttons positioned where the fingers naturally fall when clasping the device. An experienced user can enter text at 30 to 35 words per minute. No transcription is required. The input is downloaded into a computer and printed. The Data Egg can be used by an astronaut in space, a journalist, a bedridden person, etc. It was developed by a Jet Propulsion Laboratory engineer. Product is not currently manufactured.

  4. From Jefferson to Metallica to Your Campus: Copyright Issues in Student Peer-to-Peer File Sharing

    ERIC Educational Resources Information Center

    Cesarini, Lisa McHugh; Cesarini, Paul

    2008-01-01

    When Lars Ulrich, drummer for the rock group Metallica, testified before Congress about his group's lawsuit against Napster in 2000, many people who followed copyright issues in the music industry were not surprised (Ulrich, 2000). Ever since downloading audio files became as easy as clicking a few buttons on a personal computer, charges of…

  5. Illuminated push-button switch

    NASA Technical Reports Server (NTRS)

    Iwagiri, T.

    1983-01-01

    An illuminated push-button switch is described. It is characterized by the fact that is consists of a switch group, an operator button opening and closing the switch group, and a light-emitting element which illuminates the face of the operator button.

  6. Elemental properties of copper slag and measured airborne exposures at a copper slag processing facility.

    PubMed

    Mugford, Christopher; Gibbs, Jenna L; Boylstein, Randy

    2017-08-01

    In 1974, the National Institute for Occupational Safety and Health recommended a ban on the use of abrasives containing >1% silica, giving rise to abrasive substitutes like copper slag. We present results from a National Institute for Occupational Safety and Health industrial hygiene survey at a copper slag processing facility that consisted of the collection of bulk samples for metals and silica; and full-shift area and personal air samples for dust, metals, and respirable silica. Carcinogens, suspect carcinogens, and other toxic elements were detected in all bulk samples, and area and personal air samples. Area air samples identified several areas with elevated levels of inhalable and respirable dust, and respirable silica: quality control check area (236 mg/m 3 inhalable; 10.3 mg/m 3 respirable; 0.430 mg/m 3 silica), inside the screen house (109 mg/m 3 inhalable; 13.8 mg/m 3 respirable; 0.686 mg/m 3 silica), under the conveyor belt leading to the screen house (19.8 mg/m 3 inhalable), and inside a conveyor access shack (11.4 mg/m 3 inhalable; 1.74 mg/m 3 respirable; 0.067 mg/m 3 silica). Overall, personal dust samples were lower than area dust samples and did not exceed published occupational exposure limits. Silica samples collected from a plant hand and a laborer exceeded the American Conference of Governmental Industrial Hygienist Threshold Limit Value of 0.025 µg/m 3 . All workers involved in copper slag processing (n = 5) approached or exceeded the Occupational Safety and Health Administration permissible exposure limit of 10 µg/m 3 for arsenic (range: 9.12-18.0 µg/m 3 ). Personal total dust levels were moderately correlated with personal arsenic levels (R s = 0.70) and personal respirable dust levels were strongly correlated with respirable silica levels (R s = 0.89). We identified multiple areas with elevated levels of dust, respirable silica, and metals that may have implications for personal exposure at other facilities if preventive measures are not taken. To our knowledge, this is the first attempt to characterize exposures associated with copper slag processing. More in-depth air monitoring and health surveillance is needed to understand occupational exposures and health outcomes in this industry.

  7. 76 FR 54741 - Proposed Additions and Deletions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-02

    ...-6823--Button, Silver Oxide, 1.55V. NSN: 6135-01-538-0997--Button, Lithium, 3V. NSN: 6135-01-452-8160--Button, Lithium, 3V. NSN: 6135-01-301-8776--Lithium, AA, 3.6V . NSN: 6135-01-246-0307--Button, Silver...

  8. INDOOR, OUTDOOR, AND PERSONAL AIR EXPOSURES TO PARTICLES, ELEMENTS, AND NICOTINE FOR 178 RESIDENTS OF RIVERSIDE, CALIFORNIA

    EPA Science Inventory

    Personal, indoor, and outdoor concentrations of inhalable particles and 15 elements were measured for a probability sample of 178 persons representing 139,000 nonsmoking residents of Riverside, California. ewly designed personal monitors were employed. ersonal exposures often exc...

  9. Development of Computer-Supported Assessment and Treatment Consultation for Emotional Crises (CATCEC) for a Submarine Environment.

    DTIC Science & Technology

    1986-03-01

    SCHIZOPHRENIC DISORDER Amphetamine Delusional Disorder PARANOID DISORDER Cannabis Delusional Disorder Hallucinogen Delusional Disorder BRIEF REACTIVE...Intoxication Borderline Personality Disorder Cocaine Intoxication Histrionic Personality Disorder Caffeine Intoxication Narcissistic Personality Disorder... Cannabis Intoxication Dependent Personality Disorder ON, Inhalant Intoxication Schizoid Personality Disorder Minor Tranquilizer Intoxication Compulsive

  10. Empowering family physicians to impart proper inhaler teaching to patients with chronic obstructive pulmonary disease and asthma

    PubMed Central

    Leung, Janice M; Bhutani, Mohit; Leigh, Richard; Pelletier, Dan; Good, Cathy; Sin, Don D

    2015-01-01

    BACKGROUND: Patients with chronic obstructive pulmonary disease (COPD) and asthma depend on inhalers for management, but critical errors committed during inhaler use can limit drug effectiveness. Outpatient education in inhaler technique remains inconsistent due to limited resources and inadequate provider knowledge. OBJECTIVE: To determine whether a simple, two-session inhaler education program can improve physician attitudes toward inhaler teaching in primary care practice. METHODS: An inhaler education program with small-group hands-on device training was instituted for family physicians (FP) in British Columbia and Alberta. Sessions were spaced one to three months apart. All critical errors were corrected in the first session. Questionnaires surveying current inhaler teaching practices and attitudes toward inhaler teaching were distributed to physicians before and after the program. RESULTS: Forty-one (60%) of a total 68 participating FPs completed both before and after program questionnaires. Before the program, only 20 (49%) reported providing some form of inhaler teaching in their practices, and only four (10%) felt fully competent to teach patients inhaler technique. After the program, 40 (98%) rated their inhaler teaching as good to excellent. Thirty-four (83%) reported providing inhaler teaching in their practices, either by themselves or by an allied health care professional they had personally trained. All stated they could teach inhaler technique within 5 min. Observation of FPs during the second session by certified respiratory educators found that none made critical errors and all had excellent technique. CONCLUSION: A physician inhaler education program can improve attitudes toward inhaler teaching and facilitate implementation in clinical practices. PMID:26436910

  11. Fleet Environmental | USFF

    Science.gov Websites

    Leadership Expand Leadership About NEPA Projects Expand NEPA Projects At Sea Expand At Sea Ashore Expand Ashore Stewards of the Sea Expand Stewards of the Sea Media Resources Expand Media Resources Contact NEPA Projects Button Environmental At Sea Button Environmental Ashore Button Energy Button Stewards of

  12. Immigration and Schools: Policy and the Law. A Legal Memorandum: Quarterly Law Topics for School Leaders. Vol. 8, No. 3, Spring 2008

    ERIC Educational Resources Information Center

    Taylor, Kelley R.

    2008-01-01

    In recent years, immigration has become a hot-button issue--so much that mere mention of the word almost guarantees an impassioned response. Whether that response generates ideas and hope, debate and frustration, or even anger, depends on seemingly innumerable factors. Everything from personal preferences, politics, and prejudices to ethnic,…

  13. Seeing Is Believing!

    ERIC Educational Resources Information Center

    Runyan, Marla

    2013-01-01

    Most would agree that iOS technology is downright cool. But it is more than cool for a person with a visual impairment--it is accessibility built right in. At first glance, an iOS device, such as an iPhone or iPad, does not appear to be an appropriate tool for the blind. It has only a few physical buttons, and it seems to make sense only for…

  14. Electrostatic dust collectors compared to inhalable samplers for measuring endotoxin concentrations in farm homes

    PubMed Central

    Kilburg-Basnyat, Brita; Peters, Thomas M.; Perry, Sarah S.; Thorne, Peter S.

    2016-01-01

    Paired electrostatic dust collectors (EDCs) and daily, inhalable button samplers (BS) were used concurrently to sample endotoxin in 10 farm homes during 7-day periods in summer and winter. Winter sampling included an optical particle counter (OPC) to measure PM2.5 and PM2.5-10. Electrostatic dust collectors and BS filters were analyzed for endotoxin using the kinetic chromogenic Limulus amebocyte lysate assay. Optical particle counter particulate matter (PM) data were divided into two PM categories. In summer, geometric mean (geometric standard deviation) endotoxin concentrations were 0.82 EU/m3 (2.7) measured with the BS and 737 EU/m2 (1.9) measured with the EDC. Winter values were 0.52 EU/m3 (3.1) for BS and 538 EU/m2 (3.0) for EDCs. Seven day endotoxin values of EDCs were highly correlated with the 7-day BS sampling averages (r=0.70; p<0.001). Analysis of variance indicated a 2.4-fold increase in EDC endotoxin concentrations for each unit increase of the ratio of PM2.5 to PM2.5-10. There was also a significant correlation between BS and EDCs endotoxin concentrations for winter (r=0.67; p<0.05) and summer(r=0.75; p<0.05). Thus, EDCs sample comparable endotoxin concentrations to BS, making EDCs a feasible, easy to use alternative to BS for endotoxin sampling. PMID:26296624

  15. --No Title--

    Science.gov Websites

    {margin:0;padding:0;border:0;outline:0;line-height:1.3;text-decoration:none;font-size:100%;list-style:none -state-disabled{cursor:default!important}.ui-icon{display:block;text-indent:-99999px;overflow:hidden -align:middle;text-align:center;overflow:visible}.ui-button,.ui-button:link,.ui-button:visited,.ui-button:hover

  16. Button battery intake as foreign body in Chinese children: review of case reports and the literature.

    PubMed

    Liao, Wenjing; Wen, Guangyi; Zhang, Xiaowen

    2015-06-01

    Button batteries have been recognized as one of the dangerous foreign bodies to children for more than 30 years, but few related studies have been published to give more concern in China. We reported 6 cases of button battery intake as foreign body in children. The Chinese literature on button battery as foreign body in children was reviewed. The interval between the accidental ingestion and battery removal ranged from 6 hours to 3 days. Two patients had no sequela, 3 patients had tracheoesophageal fistulas, and 1 patient had nasal septal perforation. Twenty-eight articles about button battery as foreign body in children were obtained by Chinese-language literature searches including 25 case reports, 2 health education articles, and 1 imaging article. In total, 172 cases of button battery intake as foreign body in children were identified, 23 and 10 of the 159 cases involving nasal button battery lodgment developed nasal septal perforation and nasal adhesion, respectively. Tracheoesophageal fistula was identified in 4 of the 12 ingestion cases. One case of button battery intake was in external auditory canal. A small number of children with button battery as foreign body were reported in China, which is 1 of the biggest countries with large population of children.

  17. Severity of button batteries ingestions: data from French Poison Control Centres between 1999 and 2015.

    PubMed

    Labadie, Magali; O'Mahony, Elisabeth; Capaldo, Lise; Courtois, Arnaud; Lamireau, Thierry; Nisse, Patrick; Blanc-Brisset, Ingrid; Puskarczyk, Emmanuel

    2017-12-13

    Although the ingestion of button batteries is an infrequent situation, it leads to a significant risk of causing serious damage. This study was carried out to describe all the cases of button battery ingestion recorded by the French Poison Control Centers over 16 years. All the cases of button battery ingestion were recorded from 1 January 1999 to the end of June 2015, analysed (age, sex, number of ingested button batteries, clinical signs and treatments) and graded for severity according to the poisoning severity score. The incidence of button batteries ingestions was constant over the 16-year period, with an average of 266±98.5 cases per year and a total of 4030 cases. Nevertheless, 21 cases were severe and two deaths occurred. Interestingly, for the two patients who died, the battery was stuck in the oesophagus and they presented anorexia and/or dysphagia, abdominal pain and fever and in one case, a melena 3 weeks after ingestion. Importantly, these symptoms were observed even if the battery was expelled in one fatal case. Ingestions of button batteries still occur and may cause serious damage, especially in children, and if the button battery is stuck in the oesophagus as it might cause severe symptoms. Patients who have ingested a button battery must be directed to the emergency department for medical evaluation, even if the button battery has been expelled from the body and even more if gastrointestinal symptoms are present.

  18. Assessing the inhalation cancer risk of particulate matter bound polycyclic aromatic hydrocarbons (PAHs) for the elderly in a retirement community of a mega city in North China.

    PubMed

    Han, Bin; Liu, Yating; You, Yan; Xu, Jia; Zhou, Jian; Zhang, Jiefeng; Niu, Can; Zhang, Nan; He, Fei; Ding, Xiao; Bai, Zhipeng

    2016-10-01

    Assessment of the health risks resulting from exposure to ambient polycyclic aromatic hydrocarbons (PAHs) is limited by the lack of environmental exposure data among different subpopulations. To assess the exposure cancer risk of particulate carcinogenic polycyclic aromatic hydrocarbon pollution for the elderly, this study conducted a personal exposure measurement campaign for particulate PAHs in a community of Tianjin, a city in northern China. Personal exposure samples were collected from the elderly in non-heating (August-September, 2009) and heating periods (November-December, 2009), and 12 PAHs individuals were analyzed for risk estimation. Questionnaire and time-activity log were also recorded for each person. The probabilistic risk assessment model was integrated with Toxic Equivalent Factors (TEFs). Considering that the estimation of the applied dose for a given air pollutant is dependent on the inhalation rate, the inhalation rate from both EPA exposure factor book was applied to calculate the carcinogenic risk in this study. Monte Carlo simulation was used as a probabilistic risk assessment model, and risk simulation results indicated that the inhalation-ILCR values for both male and female subjects followed a lognormal distribution with a mean of 4.81 × 10 -6 and 4.57 × 10 -6 , respectively. Furthermore, the 95 % probability lung cancer risks were greater than the USEPA acceptable level of 10 -6 for both men and women through the inhalation route, revealing that exposure to PAHs posed an unacceptable potential cancer risk for the elderly in this study. As a result, some measures should be taken to reduce PAHs pollution and the exposure level to decrease the cancer risk for the general population, especially for the elderly.

  19. A newly designed hydroxyapatite ceramic burr-hole button

    PubMed Central

    Kashimura, Hiroshi; Ogasawara, Kuniaki; Kubo, Yoshitaka; Yoshida, Kenji; Sugawara, Atsushi; Ogawa, Akira

    2010-01-01

    Conventional burr-hole buttons sometimes do not fit the burr hole well due to the curvature of the surrounding bone. An irregular surface at the border between the button and the surrounding skull may appear unaesthetic. The major problem is the difference between the curvature radius of the skull and the burr-hole button in contact with the skull. To solve this problem, the authors designed a button made of hydroxyapatite ceramic to snugly fit the burr hole. The specifications of this device and its clinical application are described here. PMID:20448795

  1. A newly designed hydroxyapatite ceramic burr-hole button.

    PubMed

    Kashimura, Hiroshi; Ogasawara, Kuniaki; Kubo, Yoshitaka; Yoshida, Kenji; Sugawara, Atsushi; Ogawa, Akira

    2010-03-24

    Conventional burr-hole buttons sometimes do not fit the burr hole well due to the curvature of the surrounding bone. An irregular surface at the border between the button and the surrounding skull may appear unaesthetic. The major problem is the difference between the curvature radius of the skull and the burr-hole button in contact with the skull. To solve this problem, the authors designed a button made of hydroxyapatite ceramic to snugly fit the burr hole. The specifications of this device and its clinical application are described here.

  2. Extraction of breathing pattern using temperature sensor based on Arduino board

    NASA Astrophysics Data System (ADS)

    Patel, Rajesh; Sengottuvel, S.; Gireesan, K.; Janawadkar, M. P.; Radhakrishnan, T. S.

    2015-06-01

    Most of the basic functions of human body are assessed by measuring the different parameters from the body such as temperature, pulse activity and blood pressure etc. Respiration rate is the number of inhalations a person takes per minute and needs to be quantitatively assessed as it modulates other measurements such as SQUID based magnetocardiography (MCG) by bringing the chest closer to or away from the sensor array located inside a stationary liquid helium cryostat. The respiration rate is usually measured when a person is at rest and simply involves counting the number of inhalations for one minute. This paper aims at the development of a suitable methodology for the measurement of respiration rate with the help of a temperature sensor which monitors the very slight change in temperature near the nostril during inhalation & exhalation. The design and development of the proposed system is presented, along with typical experiment results.

  3. An analysis of employee exposure to organic dust at large-scale composting facilities

    NASA Astrophysics Data System (ADS)

    Sykes, P.; Allen, J. A.; Wildsmith, J. D.; Jones, K. P.

    2009-02-01

    The occupational health implications from exposure to dust, endotoxin and 1-3 β Glucan at commercial composting sites are uncertain. This study aims to establish employee exposure levels to inhalable and respirable dust, endotoxin and 1-3 β Glucan during various operational practices in the composting process. Personal samples were collected and the inhalable and respirable dust fractions were determined by gravimetric analysis. Endotoxin concentrations were determined using a Limulus Amebocyte Lysate assay (LAL). 1-3 β Glucan levels were estimated using a specific blocking agent to establish the contribution that these compounds gave to the original endotoxin assay. Employees' exposure to dust was found to be generally lower than the levels stipulated in the Control of Substances Hazardous to Health Regulations (COSHH) 2002 (as amended), (median inhalable fraction 1.08 mg/m3, min 0.25 mg/m3 max 10.80 mg/m3, median respirable fraction 0.05 mg/m3, min 0.02 mg/m3, max 1.49 mg/m3). Determination of the biological component of the dust showed that employees' exposures to endotoxin were elevated (median 31.5 EU/m3, min 2.00 EU/m3, max 1741.78 EU/m3), particularly when waste was agitated (median 175.0 EU/m3, min 2.03 EU/m3, max 1741.78 EU/m3). Eight out of 32 (25%) of the personal exposure data for endotoxin exceeded the 200 EU/m3 temporary legal limit adopted in the Netherlands and thirteen out of 32 (40.6%) exceeded the suggested 50 EU/m3 guidance level suggested to protect workers from respiratory health effects. A significant correlation was observed between employee inhalable dust exposure and personal endotoxin concentration (r = 0.728, p<0.05) and also personal endotoxin exposure and 1-3 β Glucan concentration (r = 0.817, p<0.05). Further work is needed to explore the possibility of using inhalable dust concentration as a predictor for personal endotoxin exposure. The general dust levels stipulated in the COSHH Regulations 2002 (as amended) are inadequate for managing the potential health risks associated with endotoxin exposure at composting sites. Employee exposure levels and dose-response disease mechanisms are not well understood at this present time. Consequently, in light of this uncertainty, it is recommended that a precautionary approach be adopted in managing the potential health risks associated with inhalation of organic dusts at composting sites.

  4. Personal inhalation exposure to polycyclic aromatic hydrocarbons in urban and rural residents in a typical northern city in China.

    PubMed

    Duan, X; Wang, B; Zhao, X; Shen, G; Xia, Z; Huang, N; Jiang, Q; Lu, B; Xu, D; Fang, J; Tao, S

    2014-10-01

    Personal inhalation exposure samples were collected and analyzed for polycyclic aromatic hydrocarbons (PAHs) for 126 selected volunteers during heating and non-heating seasons in a typical northern Chinese city, Taiyuan. Measured personal PAH exposure levels for the urban residents in the heating and non-heating seasons were 690 (540-1051) and 404 (266-544) ng/m(3) , respectively, while, for the rural residents, they were 770 (504-1071) and 312 (201-412) ng/m(3) , respectively. Thus, rural residents are exposed to lower PAH contamination in comparison with the urban residents in the non-heating seasons. In the heating season, personal PAH inhalation exposure levels were comparable between the urban and rural residents, in part owing to the large rate of residential solid fuel consumption in the rural area for household cooking and heating. The estimated incremental lifetime cancer risks (ILCR) due to PAH exposure in Taiyuan were 3.36 × 10(-5) and 2.39 × 10(-5) for the rural and urban residents, respectively, significantly higher than the literature-reported national average level, suggesting an urgent need of PAH pollution control to protect human health. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Personal Affairs: Child Development Services

    DTIC Science & Technology

    1997-07-15

    from dried paint that is chipped, peeling , or flaking in FCC homes as part of the certification process. (2) When a FCC home is determined to have paint...hazards including debris, broken glass, peeling paint, tools and construction materials, water holes, wells, and open drainage ditches. Any such hazards...Aralia, Araucaria, Areca Palm, Asparagus Fern, Aspidistra, Aster. Baby’s Breath, Baby’s Tears, Bachelor Buttons, Bamboo, Banana Plant, Begonia, Bird’s

  6. Bioaerosol assessment in naturally ventilated historical library building with restricted personnel access.

    PubMed

    Harkawy, Aleksander; Górny, Rafał L; Ogierman, Leonard; Wlazło, Agnieszka; Ławniczek-Wałczyk, Anna; Niesler, Anna

    2011-01-01

    The aim of this study was to check the degree and identify the sources of microbial contamination of the Jasna Gora (Bright Hill) monastery library 10 years after disinfection of the incunabula collection. The registered maximum viable indoor microbial concentrations were 1,875 and 7,100 cfu/m³ for stationary and personal measurements, whereas respective total concentrations were 71,000 and 100,000 counts/m3. There was no statistically significant difference between the concentrations of viable microorganisms measured in the stationary using Andersen, GSP, and Button samplers. Moreover, GSP and Button samplers can be interchangeably applied when viable or total microbial levels are stationary or personally measured. The culturable microorganisms constituted 0.5 - 3.9% of the total microflora only. Filamentous fungi were the most prevalent outdoors, whereas Gram-positive cocci and endospore forming Gram-positive rods dominated indoors in the air and settled dust, respectively. Hence, an unrestrained infiltration of ambient air through the draughtiness of the building envelope is probably the main process responsible for indoor fungal pollution, whereas bacterial contaminants have their major sources in the indoor environment. Moreover, even a chemically cleansed library collection, having a restricted personnel access, but under the influence of ambient air, can undergo microbial contamination and becomes an important microbial emission source.

  7. View of button board which accommodates the 1200 button switches ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View of button board which accommodates the 1200 button switches which manually control the indicating pilot lights on the model board. Not all switches are active, some switches were installed for a planned, but never constructed, system expansion. - Thirtieth Street Station, Load Dispatch Center, Thirtieth & Market Streets, Railroad Station, Amtrak (formerly Pennsylvania Railroad Station), Philadelphia, Philadelphia County, PA

  8. A fast button surface defects detection method based on convolutional neural network

    NASA Astrophysics Data System (ADS)

    Liu, Lizhe; Cao, Danhua; Wu, Songlin; Wu, Yubin; Wei, Taoran

    2018-01-01

    Considering the complexity of the button surface texture and the variety of buttons and defects, we propose a fast visual method for button surface defect detection, based on convolutional neural network (CNN). CNN has the ability to extract the essential features by training, avoiding designing complex feature operators adapted to different kinds of buttons, textures and defects. Firstly, we obtain the normalized button region and then use HOG-SVM method to identify the front and back side of the button. Finally, a convolutional neural network is developed to recognize the defects. Aiming at detecting the subtle defects, we propose a network structure with multiple feature channels input. To deal with the defects of different scales, we take a strategy of multi-scale image block detection. The experimental results show that our method is valid for a variety of buttons and able to recognize all kinds of defects that have occurred, including dent, crack, stain, hole, wrong paint and uneven. The detection rate exceeds 96%, which is much better than traditional methods based on SVM and methods based on template match. Our method can reach the speed of 5 fps on DSP based smart camera with 600 MHz frequency.

  9. Emotive concept nouns and motor responses: attraction or repulsion?

    PubMed

    Freina, Laura; Baroni, Giulia; Borghi, Anna M; Nicoletti, Roberto

    2009-06-01

    We carried out three experiments aimed at testing whether hand posture affects the compatibility effect that Chen and Bargh (1999) found between a word's emotional connotation and arm movement direction. In the present study, participants responded by pressing two buttons: one placed near their body, the other far away. In Experiment 1, in which they pressed the response button with their hand open, RTs were shorter when participants pressed the far button for positive words and the near button for negative words, as if they simulated reaching for something good and avoiding something bad. However, in Experiments 2 and 3, in which participants pressed the response button with a tennis ball in their hand, RTs were shorter when participants pressed the near button for positive words and the far button for negative words, as if they simulated drawing a good thing closer and pushing a bad thing away. Results are discussed within the framework of theories on concept grounding in emotion and action systems.

  10. Suture Button Fixation Versus Syndesmotic Screws in Supination-External Rotation Type 4 Injuries: A Cost-Effectiveness Analysis.

    PubMed

    Neary, Kaitlin C; Mormino, Matthew A; Wang, Hongmei

    2017-01-01

    In stress-positive, unstable supination-external rotation type 4 (SER IV) ankle fractures, implant selection for syndesmotic fixation is a debated topic. Among the available syndesmotic fixation methods, the metallic screw and the suture button have been routinely compared in the literature. In addition to strength of fixation and ability to anatomically restore the syndesmosis, costs associated with implant use have recently been called into question. This study aimed to examine the cost-effectiveness of the suture button and determine whether suture button fixation is more cost-effective than two 3.5-mm syndesmotic screws not removed on a routine postoperative basis. Economic and decision analysis; Level of evidence, 2. Studies with the highest evidence levels in the available literature were used to estimate the hardware removal and failure rates for syndesmotic screws and suture button fixation. Costs were determined by examining the average costs for patients who underwent surgery for unstable SER IV ankle fractures at a single level-1 trauma institution. A decision analysis model that allowed comparison of the 2 fixation methods was developed. Using a 20% screw hardware removal rate and a 4% suture button hardware removal rate, the total cost for 2 syndesmotic screws was US$20,836 and the total effectiveness was 5.846. This yielded a total cost of $3564 per quality-adjusted life-year (QALY) over an 8-year time period. The total cost for suture button fixation was $19,354 and the total effectiveness was 5.904, resulting in a total cost of $3294 per QALY over the same time period. A sensitivity analysis was then conducted to assess suture button fixation costs as well as screw and suture button hardware removal rates. Other possible treatment scenarios were also examined, including 1 screw and 2 suture buttons for operative fixation of the syndesmosis. To become more cost-effective, the screw hardware removal rate would have to be reduced to less than 10%. Furthermore, fixation with a single suture button continued to be the dominant treatment strategy compared with 2 suture buttons, 1 screw, and 2 screws for syndesmotic fixation. This cost-effectiveness analysis suggests that for unstable SER IV ankle fractures, suture button fixation is more cost-effective than syndesmotic screws not removed on a routine basis. Suture button fixation was a dominant treatment strategy, because patients spent on average $1482 less and had a higher quality of life by 0.058 QALYs compared with patients who received fixation with 2 syndesmotic screws. Assuming that functional outcomes and failure rates were equivalent, screw fixation only became more cost-effective when the screw hardware removal rate was reduced to less than 10% or when the suture button cost exceeded $2000. In addition, fixation with a single suture button device proved more cost-effective than fixation with either 1 or 2 syndesmotic screws.

  11. The Emerging Role of 3-Dimensional Printing in Rhinology.

    PubMed

    Stokken, Janalee K; Pallanch, John F

    2017-06-01

    Nasal septal perforations, particularly those that are large and irregular in shape, often present as challenging surgical dilemmas. New technology has allowed us to develop techniques using computed tomography imaging and 3-dimensional (3D) printers to design custom polymeric silicone septal buttons. These buttons offer patients an option that avoids a surgical intervention when standard buttons do not fit well or are not tolerated. Preliminary data suggest that buttons designed by 3D printer technology provide more comfort than standard commercially available or hand-carved buttons with equivalent reduction of symptoms. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Risk analysis for worker exposure to benzene

    NASA Astrophysics Data System (ADS)

    Hallenbeck, William H.; Flowers, Roxanne E.

    1992-05-01

    Cancer risk factors (characterized by route, dose, dose rate per kilogram, fraction of lifetime exposed, species, and sex) were derived for workers exposed to benzene via inhalation or ingestion. Exposure at the current Occupational Safety and Health Administration (OSHA) permissible exposure limit (PEL) and at leaking underground storage tank (LUST) sites were evaluated. At the current PEL of 1 ppm, the theoretical lifetime excess risk of cancer from benzene inhalation is ten per 1000. The theoretical lifetime excess risk for worker inhalation exposure at LUST sites ranged from 10 to 40 per 1000. These results indicate that personal protection should be required. The theoretical lifetime excess risk due to soil ingestion is five to seven orders of magnitude less than the inhalation risks.

  13. 49 CFR 175.630 - Special requirements for Division 6.1 (poisonous) material and Division 6.2 (infectious...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... (infectious substances) materials. (a) A package required to bear a POISON, POISON INHALATION HAZARD, or... person may operate an aircraft that has been used to transport any package required to bear a POISON or POISON INHALATION HAZARD label unless, upon removal of such package, the area in the aircraft in which it...

  14. 49 CFR 175.630 - Special requirements for Division 6.1 (poisonous) material and Division 6.2 (infectious...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... (infectious substances) materials. (a) A package required to bear a POISON, POISON INHALATION HAZARD, or... person may operate an aircraft that has been used to transport any package required to bear a POISON or POISON INHALATION HAZARD label unless, upon removal of such package, the area in the aircraft in which it...

  15. 49 CFR 175.630 - Special requirements for Division 6.1 (poisonous) material and Division 6.2 (infectious...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... (infectious substances) materials. (a) A package required to bear a POISON, POISON INHALATION HAZARD, or... person may operate an aircraft that has been used to transport any package required to bear a POISON or POISON INHALATION HAZARD label unless, upon removal of such package, the area in the aircraft in which it...

  16. 49 CFR 175.630 - Special requirements for Division 6.1 (poisonous) material and Division 6.2 (infectious...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... (infectious substances) materials. (a) A package required to bear a POISON, POISON INHALATION HAZARD, or... person may operate an aircraft that has been used to transport any package required to bear a POISON or POISON INHALATION HAZARD label unless, upon removal of such package, the area in the aircraft in which it...

  17. Virtual button interface

    DOEpatents

    Jones, Jake S.

    1999-01-01

    An apparatus and method of issuing commands to a computer by a user interfacing with a virtual reality environment. To issue a command, the user directs gaze at a virtual button within the virtual reality environment, causing a perceptible change in the virtual button, which then sends a command corresponding to the virtual button to the computer, optionally after a confirming action is performed by the user, such as depressing a thumb switch.

  18. Effect of blood contamination on shear bond strength of orthodontic brackets and disinclusion buttons.

    PubMed

    Sfondrini, Maria Francesca; Gatti, Sara; Scribante, Andrea

    2011-07-01

    Our aim was to assess the effect of blood contamination on the shear bonding strength and sites of failure of orthodontic brackets and bondable buttons. We randomly divided 160 bovine permanent mandibular incisors into 8 groups of 20 specimens each. Both orthodontic brackets (Step brackets, Leone, Sesto Fiorentino, Italy) and bondable buttons (Flat orthodontic buttons, Leone, Sesto Fiorentino, Italy) were tested on four different enamel surfaces: dry; contamination with blood before priming; after priming; and before and after priming. Brackets and buttons were bonded to the teeth and subsequently tested using a Instron universal testing machine. Shear bonding strength and the rate of adhesive failures were recorded. Data were analysed using the analysis of variance (ANOVA), Scheffè tests, and the chi-square test. Uncontaminated enamel surfaces showed the highest bonding strengths for both brackets and buttons. When they were contaminated with blood, orthodontic brackets had significantly lower shear strengths than bondable buttons (P=0.0001). There were significant differences in sites of failure among the groups for the various enamel surfaces (P=0.001). Contamination of enamel by blood during bonding lowers the strength of the bond, more so with orthodontic brackets than with bondable buttons. Copyright © 2010 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  19. Widgets and Buttons

    MedlinePlus

    ... Home → Widgets and Buttons URL of this page: https://medlineplus.gov/widgets.html Widgets and Buttons To ... link the word MedlinePlus to the MedlinePlus homepage ( https://medlineplus.gov/ ). Search MedlinePlus : To put the MedlinePlus ...

  20. Shear bond strength of orthodontic brackets and disinclusion buttons: effect of water and saliva contamination.

    PubMed

    Sfondrini, Maria Francesca; Fraticelli, Danilo; Gandini, Paola; Scribante, Andrea

    2013-01-01

    The aim of this study was to assess the effect of water and saliva contamination on the shear bond strength and failure site of orthodontic brackets and lingual buttons. 120 bovine permanent mandibular incisors were randomly divided into 6 groups of 20 specimens each. Both orthodontic brackets and disinclusion buttons were tested under three different enamel surface conditions: (a) dry, (b) water contamination, and (c) saliva contamination. Brackets and buttons were bonded to the teeth and subsequently tested using a Instron universal testing machine. Shear bond strength values and adhesive failure rate were recorded. Statistical analysis was performed using ANOVA and Tukey tests (strength values) and Chi squared test (ARI Scores). Noncontaminated enamel surfaces showed the highest bond strengths for both brackets and buttons. Under water and saliva contamination orthodontic brackets groups showed significantly lower shear strengths than disinclusion buttons groups. Significant differences in debond locations were found among the groups under the various enamel surface conditions. Water and saliva contamination of enamel during the bonding procedure lowers bond strength values, more with orthodontic brackets than with disinclusion buttons.

  1. Personal Exposure to Inhalable Dust and the Specific Latex Aero-Allergen, Hev b6.02, in Latex Glove Manufacturing in Thailand

    PubMed Central

    Sanguanchaiyakrit, Nuthchyawach; Povey, Andrew C.; de Vocht, Frank

    2014-01-01

    Objectives: Latex product manufacturing is an important industry in south-east Asia but has the potential for considerable occupational exposure of workers to latex allergens. Although exposure to latex allergens can result in adverse health reactions, few studies to characterize this exposure have been conducted to date. This study therefore aimed to characterize current airborne inhalable dust and the specific allergen, Hev b 6.02, exposures in this industry in Thailand. Methods: Workers were recruited from three factories in the southern part of Thailand. Full-shift inhalable dust personal air sampling was conducted using IOM sampling heads equipped with polytetrafluoroethylene filters at a 2.0 l min−1 flowrate. After weighing to determine inhalable dust levels, filters were extracted and analysed for Hev b 6.02 using an enzyme immunometric assay. Results: Two hundred and seventy-five workers agreed to participate, resulting in a total of 292 measurements. Geometric mean (GM) personal exposure to inhalable dust was 0.88mg m–3, but individual exposures up to 12.34mg m–3 were measured. The pattern of exposure was similar across factories, with highest exposures in the stripping (GM 2.08–4.05mg m–3 for the 3 factories) and tumbling departments (1.11–2.17mg m–3). Within-worker (day-to-day) variability contributed 92% to total variability. The Hev b 6.02 exposure pattern was similar with time-weighted average GM exposure levels in the oldest factory ranging from 8.7mg m–3 in the laboratory to 30.2mg m–3 in the stripping department. In contrast to inhalable dust exposure, total exposure variability was primary driven by variability between workers (67%). Conclusions: Workers in these latex product factories get routinely exposed to measurable Hev b 6.02 levels, which may give rise to increased incidence of allergic symptoms and occupational asthma. Also, in this measurement campaign a 10mg m–3, but not 15mg m–3, occupational exposure limit for inhalable dust was occasionally exceeded. Highest Hev b 6.02 exposures were found in the stripping and tumbling departments, which would be natural targets for interventions aimed at reducing exposure. PMID:24569810

  2. Personal exposure to inhalable dust and the specific latex aero-allergen, Hev b6.02, in latex glove manufacturing in Thailand.

    PubMed

    Sanguanchaiyakrit, Nuthchyawach; Povey, Andrew C; de Vocht, Frank

    2014-06-01

    Latex product manufacturing is an important industry in south-east Asia but has the potential for considerable occupational exposure of workers to latex allergens. Although exposure to latex allergens can result in adverse health reactions, few studies to characterize this exposure have been conducted to date. This study therefore aimed to characterize current airborne inhalable dust and the specific allergen, Hev b 6.02, exposures in this industry in Thailand. Workers were recruited from three factories in the southern part of Thailand. Full-shift inhalable dust personal air sampling was conducted using IOM sampling heads equipped with polytetrafluoroethylene filters at a 2.0 l min(-1) flowrate. After weighing to determine inhalable dust levels, filters were extracted and analysed for Hev b 6.02 using an enzyme immunometric assay. Two hundred and seventy-five workers agreed to participate, resulting in a total of 292 measurements. Geometric mean (GM) personal exposure to inhalable dust was 0.88 mg m(-3), but individual exposures up to 12.34 mg m(-3) were measured. The pattern of exposure was similar across factories, with highest exposures in the stripping (GM 2.08-4.05 mg m(-3) for the 3 factories) and tumbling departments (1.11-2.17 mg m(-3)). Within-worker (day-to-day) variability contributed 92% to total variability. The Hev b 6.02 exposure pattern was similar with time-weighted average GM exposure levels in the oldest factory ranging from 8.7 mg m(-3) in the laboratory to 30.2mg m(-3) in the stripping department. In contrast to inhalable dust exposure, total exposure variability was primary driven by variability between workers (67%). Workers in these latex product factories get routinely exposed to measurable Hev b 6.02 levels, which may give rise to increased incidence of allergic symptoms and occupational asthma. Also, in this measurement campaign a 10mg m(-3), but not 15 mg m(-3), occupational exposure limit for inhalable dust was occasionally exceeded. Highest Hev b 6.02 exposures were found in the stripping and tumbling departments, which would be natural targets for interventions aimed at reducing exposure. © The Author 2014. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  3. Virtual button interface

    DOEpatents

    Jones, J.S.

    1999-01-12

    An apparatus and method of issuing commands to a computer by a user interfacing with a virtual reality environment are disclosed. To issue a command, the user directs gaze at a virtual button within the virtual reality environment, causing a perceptible change in the virtual button, which then sends a command corresponding to the virtual button to the computer, optionally after a confirming action is performed by the user, such as depressing a thumb switch. 4 figs.

  4. EEG alpha activity and hallucinatory experience during sensory deprivation.

    PubMed

    Hayashi, M; Morikawa, T; Hori, T

    1992-10-01

    The relationship between hallucinatory experiences under sensory deprivation and EEG alpha activities was studied. Each of seven male students lived alone in an air conditioned, soundproof dark room for 72 hours. When hallucinatory experiences occurred, the students pressed a button at once. If they could not press the button during the experience, they were required to press it two times when the hallucinatory experience was finished. Spectral analysis was performed on the consecutive EEG samples from just before button-presses to 10 min. before them, and the average alpha band amplitudes were obtained for the four epochs (0-.5, .5-2, 2-5, 5-10 min.). For the single button-presses, the amplitude of alpha band increased 2 min. before the button-presses. Right-hemisphere EEG activation was observed in the occipital area for the double button-presses. The results suggest an association between the hallucinatory experiences under sensory deprivation and the amount of EEG alpha activity.

  5. Advances in Audio-Based Systems to Monitor Patient Adherence and Inhaler Drug Delivery.

    PubMed

    Taylor, Terence E; Zigel, Yaniv; De Looze, Céline; Sulaiman, Imran; Costello, Richard W; Reilly, Richard B

    2018-03-01

    Hundreds of millions of people worldwide have asthma and COPD. Current medications to control these chronic respiratory diseases can be administered using inhaler devices, such as the pressurized metered dose inhaler and the dry powder inhaler. Provided that they are used as prescribed, inhalers can improve patient clinical outcomes and quality of life. Poor patient inhaler adherence (both time of use and user technique) is, however, a major clinical concern and is associated with poor disease control, increased hospital admissions, and increased mortality rates, particularly in low- and middle-income countries. There are currently limited methods available to health-care professionals to objectively and remotely monitor patient inhaler adherence. This review describes recent sensor-based technologies that use audio-based approaches that show promising opportunities for monitoring inhaler adherence in clinical practice. This review discusses how one form of sensor-based technology, audio-based monitoring systems, can provide clinically pertinent information regarding patient inhaler use over the course of treatment. Audio-based monitoring can provide health-care professionals with quantitative measurements of the drug delivery of inhalers, signifying a clear clinical advantage over other methods of assessment. Furthermore, objective audio-based adherence measures can improve the predictability of patient outcomes to treatment compared with current standard methods of adherence assessment used in clinical practice. Objective feedback on patient inhaler adherence can be used to personalize treatment to the patient, which may enhance precision medicine in the treatment of chronic respiratory diseases. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  6. Inhalant use among schoolchildren in northeast India: a preliminary study.

    PubMed

    Akoijam, Brogen Singh; Jamir, M Nukshisangla; Phesao, Ebenezer; Senjam, Gojendra Singh

    2013-01-01

    Inhalant use by children leads to poor performance in school and has been observed to precede substance use later in life. There is paucity of data on inhalant use among school children in India, particularly in the Northeast region of the country. We determined the prevalence and documented inhalant use characteristics among schoolchildren in the Northeast region of India. This cross sectional study was conducted in six states in the Northeast region of India. Schoolchildren between eighth and eleventh standards from the capital areas of the states were included in the study. Data were collected using a questionnaire. Analysis was done using descriptive statistics and Chi-square test. Of the 4074 enrolled students, data from 3943 students who responded to the inhalant use question were analyzed. Mean age was 14.8 ± 1.2 years and 51.2% of participants were male. The proportion of students who had ever used inhalants (ever user) was 18.8% and adhesive/glue was the inhalant misused by most of the students. A higher proportion of males than females were ever users (P ≤ 0.001) and the most common place of use was at home (33.1%). Being in the presence of an older person using an inhalant or tobacco was found to be associated with use of inhalants among students. Nearly one-fifth of the students had used inhalants and nearly half used inhalants in the past month. Sensitization of the parents and school authorities to the problem, as well as preventive and curative services, should be considered.

  7. The anesthetic management of button battery ingestion in children.

    PubMed

    Ing, Richard J; Hoagland, Monica; Mayes, Lena; Twite, Mark

    2018-03-01

    Injuries related to button battery ingestion are common in children. This review provides an outline of the epidemiology, pathophysiology, management, and anesthetic implications in children who have ingested a button battery. A literature search was conducted in the United States National Library of Medicine PubMed database using the terms "button battery ingestion" and "children' and "removal" and "surgery" and "anesthesia". Ninety-six articles published in English were found from 1983-2017, and 62 of these articles were incorporated into this review. Additionally, the Internet was searched with the terms "button battery ingestion and children" to identify further entities, organizations, and resources affiliated with button battery ingestion in children. These additional sources were studied and included in this review. Button batteries are ubiquitous in homes and electronic devices. Since 2006, larger-diameter and higher-voltage batteries have become available. These are more likely to become impacted in the esophagus after ingestion and lead to an increase in severe morbidity and mortality due to caustic tissue injury. Children at the highest risk for complications are those under six years of age who have ingested batteries > 20 mm in diameter and sustain prolonged esophageal impaction at the level of the aortic arch with the negative pole oriented anteriorly. Anesthesiologists need to know about the epidemiology, pathophysiology, complications, and anesthetic management of children who have ingested button batteries.

  8. Measurements of the levels of organic solvent vapours by personal air samplers and the levels of urinary metabolites of workers. Part 2. Toluene vapour in a shipbuilding yard (author's transl).

    PubMed

    Kira, S

    1977-05-01

    Personal air samplers were applied to shipyard's painters putting on gas masks during the spraying work, and the levels of toluene vapour surrounding the workers were measured. On the other hand, levels of urinary hippuric acid (metabolites of toluene) of the workers were measured, and the levels of toluene vapour inhaled were calculated from the levels of urinary hippuric acid. Then the actual removing-efficiencies of toluene vapours by the use of gas masks were estimated from these two levels (i.e., toluene vapours exposed and inhaled). The values of removing-efficiencies were found to be 65.9-98.1%. The concentrations of hippuric and methylhippuric acids in the urine of workers exposed to toluene and xylene for 3 hours, collected just after the exposure, are valuable indices of these organic solvent vapours inhaled. A minute amount of urinary methylhippuric acid can be determined by means of gas chromatography.

  9. A comparison of two laboratories for the measurement of wood dust using button sampler and diffuse reflection infrared Fourier-transform spectroscopy (DRIFTS).

    PubMed

    Chirila, Madalina M; Sarkisian, Khachatur; Andrew, Michael E; Kwon, Cheol-Woong; Rando, Roy J; Harper, Martin

    2015-04-01

    The current measurement method for occupational exposure to wood dust is by gravimetric analysis and is thus non-specific. In this work, diffuse reflection infrared Fourier transform spectroscopy (DRIFTS) for the analysis of only the wood component of dust was further evaluated by analysis of the same samples between two laboratories. Field samples were collected from six wood product factories using 25-mm glass fiber filters with the Button aerosol sampler. Gravimetric mass was determined in one laboratory by weighing the filters before and after aerosol collection. Diffuse reflection mid-infrared spectra were obtained from the wood dust on the filter which is placed on a motorized stage inside the spectrometer. The metric used for the DRIFTS analysis was the intensity of the carbonyl band in cellulose and hemicellulose at ~1735 cm(-1). Calibration curves were constructed separately in both laboratories using the same sets of prepared filters from the inhalable sampling fraction of red oak, southern yellow pine, and western red cedar in the range of 0.125-4 mg of wood dust. Using the same procedure in both laboratories to build the calibration curve and analyze the field samples, 62.3% of the samples measured within 25% of the average result with a mean difference between the laboratories of 18.5%. Some observations are included as to how the calibration and analysis can be improved. In particular, determining the wood type on each sample to allow matching to the most appropriate calibration increases the apparent proportion of wood dust in the sample and this likely provides more realistic DRIFTS results. Published by Oxford University Press on behalf of the British Occupational Hygiene Society 2014.

  10. Shear Bond Strength of Orthodontic Brackets and Disinclusion Buttons: Effect of Water and Saliva Contamination

    PubMed Central

    Sfondrini, Maria Francesca; Fraticelli, Danilo; Gandini, Paola

    2013-01-01

    Purpose. The aim of this study was to assess the effect of water and saliva contamination on the shear bond strength and failure site of orthodontic brackets and lingual buttons. Materials and Methods. 120 bovine permanent mandibular incisors were randomly divided into 6 groups of 20 specimens each. Both orthodontic brackets and disinclusion buttons were tested under three different enamel surface conditions: (a) dry, (b) water contamination, and (c) saliva contamination. Brackets and buttons were bonded to the teeth and subsequently tested using a Instron universal testing machine. Shear bond strength values and adhesive failure rate were recorded. Statistical analysis was performed using ANOVA and Tukey tests (strength values) and Chi squared test (ARI Scores). Results. Noncontaminated enamel surfaces showed the highest bond strengths for both brackets and buttons. Under water and saliva contamination orthodontic brackets groups showed significantly lower shear strengths than disinclusion buttons groups. Significant differences in debond locations were found among the groups under the various enamel surface conditions. Conclusions. Water and saliva contamination of enamel during the bonding procedure lowers bond strength values, more with orthodontic brackets than with disinclusion buttons. PMID:23762825

  11. Evaluation of Heat Dissipation in the BPM Buttons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pinayev,I.; Blednyhk, A.

    2009-05-04

    Growth of circulating current in the storage rings drastically increases heating of the beam position monitor (BPM) buttons due to the induced trapped modes is drastically increasing. Excessive heating can lead to the errors in the measuring of beam position or even catastrophic failures of the pick-up assembly. In this paper we present calculations of heat generated in the button for different geometries and materials. The obtained results are used for the optimization of the NSLS-II BPM buttons design.

  12. Comparative Study of button BPM Trapped Mode Heating

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cameron,P.; Singh, O.

    2009-05-04

    The combination of short bunches and high currents found in modern light sources and colliders can result in the deposition of tens of watts of power in BPM buttons. The resulting thermal distortion is potentially problematic for maintaining high precision beam position stability, and in the extreme case can result in mechanical damage. We present a simple algorithm that uses the input parameters of beam current, bunch length, button diameter, beampipe aperture, and fill pattern to calculate a relative figure-of-merit for button heating. Data for many of the world's light sources and colliders is compiled in a table. Using themore » algorithm, the table is sorted in order of the relative magnitude of button heating.« less

  13. Delinquency and family problems in incarcerated adolescents with and without a history of inhalant use.

    PubMed

    McGarvey, E L; Canterbury, R J; Waite, D

    1996-01-01

    In this retrospective study of incarcerated adolescents, inhalants were used by significantly more nonminority than minority youth. Among both minority and nonminority groups, family problems and delinquent behaviors were higher among those youth with a history of inhalant use than those who reported no use. Family problems included history of running away from home, breaking rules, fighting with parents, and having relatives who had attempted suicide. Delinquent behavior included earlier personal use of drugs, selling illegal drugs, buying drugs from dealers, committing crimes while under the influence, committing crimes to get money to buy drugs, and threatening to hurt people.

  14. Effect of drivers' age and push button locations on visual time off road, steering wheel deviation and safety perception.

    PubMed

    Dukic, T; Hanson, L; Falkmer, T

    2006-01-15

    The study examined the effects of manual control locations on two groups of randomly selected young and old drivers in relation to visual time off road, steering wheel deviation and safety perception. Measures of visual time off road, steering wheel deviations and safety perception were performed with young and old drivers during real traffic. The results showed an effect of both driver's age and button location on the dependent variables. Older drivers spent longer visual time off road when pushing the buttons and had larger steering wheel deviations. Moreover, the greater the eccentricity between the normal line of sight and the button locations, the longer the visual time off road and the larger the steering wheel deviations. No interaction effect between button location and age was found with regard to visual time off road. Button location had an effect on perceived safety: the further away from the normal line of sight the lower the rating.

  15. Relationships between Personal Measurements of 'Total' Dust, Respirable, Thoracic, and Inhalable Aerosol Fractions in the Cement Production Industry.

    PubMed

    Notø, Hilde P; Nordby, Karl-Christian; Eduard, Wijnand

    2016-05-01

    The aims of this study were to examine the relationships and establish conversion factors between 'total' dust, respirable, thoracic, and inhalable aerosol fractions measured by parallel personal sampling on workers from the production departments of cement plants. 'Total' dust in this study refers to aerosol sampled by the closed face 37-mm Millipore filter cassette. Side-by-side personal measurements of 'total' dust and respirable, thoracic, and inhalable aerosol fractions were performed on workers in 17 European and Turkish cement plants. Simple linear and mixed model regressions were used to model the associations between the samplers. The total number of personal samples collected on 141 workers was 512. Of these 8.4% were excluded leaving 469 for statistical analysis. The different aerosol fractions contained from 90 to 130 measurements and-side-by side measurements of all four aerosol fractions were collected on 72 workers.The median ratios between observed results of the respirable, 'total' dust, and inhalable fractions relative to the thoracic aerosol fractions were 0.51, 2.4, and 5.9 respectively. The ratios between the samplers were not constant over the measured concentration range and were best described by regression models. Job type, position of samplers on left or right shoulder and plant had no substantial effect on the ratios. The ratios between aerosol fractions changed with different air concentrations. Conversion models for estimation of the fractions were established. These models explained a high proportion of the variance (74-91%) indicating that they are useful for the estimation of concentrations based on measurements of a different aerosol fraction. The calculated uncertainties at most observed concentrations were below 30% which is acceptable for comparison with limit values (EN 482, 2012). The cement industry will therefore be able to predict the health related aerosol fractions from their former or future measurements of one of the fractions. © The Author 2016. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  16. Lower complication rate and faster return to sports in patients with acute syndesmotic rupture treated with a new knotless suture button device.

    PubMed

    Colcuc, Christian; Blank, Marc; Stein, Thomas; Raimann, Florian; Weber-Spickschen, Sanjay; Fischer, Sebastian; Hoffmann, Reinhard

    2017-12-09

    Suture button devices for tibiofibular syndesmosis injuries provide semirigid dynamic stabilization, but complications including knot irritation have been reported. No randomized trials of the new knotless suture button devices have been performed. We hypothesized that knotless suture button devices eliminate knot irritation and facilitate quicker return to sports. This study was performed to compare the clinical outcomes, complication rates, and time to return to sports between a new knotless suture button device and syndesmotic screw fixation. This study included 54 patients treated for ankle syndesmotic injury from 2012 to 2014 with a knotless suture button device or syndesmotic screw fixation. Clinical outcomes were measured using the American Orthopaedics Foot and Ankle Society score, Foot and Ankle Disability Index, Olerud and Molander score, and visual analog scale for pain and function. Secondary outcome measures were the complication rate and time required to return to sports. Patients underwent clinical and radiological evaluations preoperatively and three times during the 1-year postoperative follow-up. 54 of 62 eligible patients were analyzed, median age 37 (18-60) and underwent the 1-year follow-up. The screw fixation and knotless suture button groups comprised 26 and 28 patients, respectively. The complication rate was significantly lower (p = 0.03) and time to return to sports was significantly shorter in the knotless suture button than screw fixation group (average, 14 versus 19 weeks, respectively; p = 0.006). No significant differences were identified in clinical outcomes or visual analog scale scores for pain and function between the groups. Age, injury mechanism, and body mass index did not significantly affect the time required to return to sports activities. The type of fixation was the only independent variable that reached statistical significance (p = 0.006). Syndesmotic screw fixation and the new knotless suture button device both resulted in good clinical results. Lower complication rate and the earlier time to return to sports make the new knotless suture button device recommendable especially for highly active patients. Randomized controlled trial, Level I.

  17. 46 CFR 160.037-3 - Materials, workmanship, construction, and performance requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... on its top with a friction striking material which shall, by a pull of the tear strip, be entirely exposed for striking the friction igniter button. The igniter button shall be non-water soluble or be... manner as to provide positive ignition by the friction striker. The igniter button shall be firmly...

  18. 46 CFR 160.037-3 - Materials, workmanship, construction, and performance requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... on its top with a friction striking material which shall, by a pull of the tear strip, be entirely exposed for striking the friction igniter button. The igniter button shall be non-water soluble or be... manner as to provide positive ignition by the friction striker. The igniter button shall be firmly...

  19. 46 CFR 160.037-3 - Materials, workmanship, construction, and performance requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... on its top with a friction striking material which shall, by a pull of the tear strip, be entirely exposed for striking the friction igniter button. The igniter button shall be non-water soluble or be... manner as to provide positive ignition by the friction striker. The igniter button shall be firmly...

  20. 46 CFR 160.037-3 - Materials, workmanship, construction, and performance requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... on its top with a friction striking material which shall, by a pull of the tear strip, be entirely exposed for striking the friction igniter button. The igniter button shall be non-water soluble or be... manner as to provide positive ignition by the friction striker. The igniter button shall be firmly...

  1. Distal Attachment of Flexor Tendon Allograft: A Biomechanical Study of Different Reconstruction Techniques in Human Cadaver Hands

    PubMed Central

    Wei, Zhuang; Thoreson, Andrew R.; Amadio, Peter C.; An, Kai-Nan; Zhao, Chunfeng

    2014-01-01

    We compared the mechanical force of tendon-to-bone repair techniques for flexor tendon reconstruction. Thirty-six flexor digitorum profundus (FDP) tendons were divided into three groups based upon the repair technique: (1) suture/button repair using FDP tendon (Pullout button group), (2) suture bony anchor using FDP tendon (Suture anchor group), and (3) suture/button repair using FDP tendon with its bony attachment preserved (Bony attachment group). The repair failure force and stiffness were measured. The mean load to failure and stiffness in the bony attachment group were significantly higher than that in the pullout button and suture anchor groups. No significant difference was found in failure force and stiffness between the pullout button and suture anchor groups. An intrasynovial flexor tendon graft with its bony attachment has significantly improved tensile properties at the distal repair site when compared with a typical tendon-to-bone attachment with a button or suture anchor. The improvement in the tensile properties at the repair site may facilitate postoperative rehabilitation and reduce the risk of graft rupture. PMID:23754507

  2. Results from a Test Fixture for button BPM Trapped Mode Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cameron,P.; Bacha, B.; Blednykh, A.

    2009-05-04

    A variety of measures have been suggested to mitigate the problem of button BPM trapped mode heating. A test fixture, using a combination of commercial-off-the-shelf and custom machined components, was assembled to validate the simulations. We present details of the fixture design, measurement results, and a comparison of the results with the simulations. A brief history of the trapped mode button heating problem and a set of design rules for BPM button optimization are presented elsewhere in these proceedings. Here we present measurements on a test fixture that was assembled to confirm, if possible, a subset of those rules: (1)more » Minimize the trapped mode impedance and the resulting power deposited in this mode by the beam. (2) Maximize the power re-radiated back into the beampipe. (3) Maximize electrical conductivity of the outer circumference of the button and minimize conductivity of the inner circumference of the shell, to shift power deposition from the button to the shell. The problem is then how to extract useful and relevant information from S-parameter measurements of the test fixture.« less

  3. A Comparison of "Total Dust" and Inhalable Personal Sampling for Beryllium Exposure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carter, Colleen M.

    2012-05-09

    In 2009, the American Conference of Governmental Industrial Hygienists (ACGIH) reduced the Beryllium (Be) 8-hr Time Weighted Average Threshold Limit Value (TLV-TWA) from 2.0 μg/m 3 to 0.05 μg/m 3 with an inhalable 'I' designation in accordance with ACGIH's particle size-selective criterion for inhalable mass. Currently, per the Department of Energy (DOE) requirements, the Lawrence Livermore National Laboratory (LLNL) is following the Occupational Health and Safety Administration (OSHA) Permissible Exposure Limit (PEL) of 2.0 μg/m 3 as an 8-hr TWA, which is also the 2005 ACGIH TLV-TWA, and an Action Level (AL) of 0.2 μg/m 3 and sampling is performedmore » using the 37mm (total dust) sampling method. Since DOE is considering adopting the newer 2009 TLV guidelines, the goal of this study was to determine if the current method of sampling using the 37mm (total dust) sampler would produce results that are comparable to what would be measured using the IOM (inhalable) sampler specific to the application of high energy explosive work at LLNL's remote experimental test facility at Site 300. Side-by-side personal sampling using the two samplers was performed over an approximately two-week period during chamber re-entry and cleanup procedures following detonation of an explosive assembly containing Beryllium (Be). The average ratio of personal sampling results for the IOM (inhalable) vs. 37-mm (total dust) sampler was 1.1:1 with a P-value of 0.62, indicating that there was no statistically significant difference in the performance of the two samplers. Therefore, for the type of activity monitored during this study, the 37-mm sampling cassette would be considered a suitable alternative to the IOM sampler for collecting inhalable particulate matter, which is important given the many practical and economic advantages that it presents. However, similar comparison studies would be necessary for this conclusion to be applied to other types of activities, where earlier studies have shown that the IOM sampler tends to collect higher concentrations of Be compared to the 37-mm cassette, which could complicate compliance with what is already an extremely low exposure limit.« less

  4. Decontamination and decorporation: the clinical experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poda, G.A.

    1979-01-01

    Decontamination and decorporation are quite interrelated when dealing with a contaminated person. Some clinical experiences from a transuranium production facility are offered. Skin decontamination is accomplished by washing with detergent and water. Stubborn cases are treated with sodium hypochlorite followed by rinsing, and emery cloth is used on more stubborn nail or finger pad contamination. If inhaled, the usual skin cleansing followed by nasal douche with normal saline decontaminates reachable areas and one of the DTPA salts given via aerosol both decontaminates and decorporates the inner recesses. Saline laxative reduces the time inhaled, and ingested particles remain in the gastro-intestinalmore » tract. Conservatism prevails in general, but most persons found to have inhaled contamination are given a single chelation within the hour of discovery and if subsequently found to have over 10% M.P.P.B. of a soluble actinide are offered further chelation. Single dose chelation has been found to be relatively innocuous and usually sufficient. The longest case of chelation therapy spanned 2-1/4 years and encompassed 123 doses of CaNa-DTPA.« less

  5. Nasal foreign bodies in children: should they have a plain radiograph in the accident and emergency?

    PubMed

    Glynn, Fergal; Amin, Mohamed; Kinsella, John

    2008-04-01

    To determine the proportion of children with nasal foreign bodies who had button batteries as the foreign body. To describe the clinical care and outcome of those children with a button battery foreign body. A retrospective review of all children presenting to the accident and emergency room with a nasal foreign body or unilateral nasal discharge during a 6-month period was assessed. Forty-four children were included. The most common object found was a plastic bead (27%), followed by foam, paper, or tissue fragments (23%); food matter represented 15%. A button battery was found in 3 patients (7%); other foreign bodies included stones, buttons, crayons, erasers, and a pellet. Thiry-six (82%) had their foreign body removed without anesthetic and 8 (18%) required a general anesthetic. All 3 children with a button battery went undiagnosed until examination in the operating theater. Because there was no previous indication of the presence of a button battery in the 3 children, the removal of the foreign body under general anesthesia was scheduled for the following day. The removal of the button batteries would have been expedited had a plain radiograph been obtained, possibly resulting in less morbidity for our patients. We recommend a plain radiograph in all children presenting with a nonvisible foreign body or unilateral nasal discharge.

  6. Training Presentation for NASA Civil Helicopter Safety Website

    NASA Technical Reports Server (NTRS)

    Iseler, Laura

    2002-01-01

    NASA civil helicopter safety News & Updates include the following: Mar. 2002. The Air Medical Operations Survey has been completed! Check it out! Also accessible via the Mission pages under Air Medical Mission. Air Medical and Law Enforcement Mission pages have been added. They are accessible via the Mission pages. The Public Use, Personal, Offshore, Law Enforcement, External Load, Business and Gyro accident pages (accessable via the Mission page) have been updated. Feb. 2002. A Words of Wisdom section has been added. You can access it by clicking the Library button. A link to a Corporate Accident Response Plan has been added to the Accident page. The AMs, Aerial Application and Instruction accident pages (accessable via the Mission page) have been updated. Jan. 2002. A new searchable safety article database has been added. You can access it by clicking the Library button. The 2001 accident summaries have been updated and the statistics have been compiled - check it out by clicking the accident tab to the left. Dec. 2001. Please read the FAA Administrator's memo regarding the latest FBI warning. 3ee the FAA column - Fall 2001 Read it now!

  7. Development of an automated speech recognition interface for personal emergency response systems

    PubMed Central

    Hamill, Melinda; Young, Vicky; Boger, Jennifer; Mihailidis, Alex

    2009-01-01

    Background Demands on long-term-care facilities are predicted to increase at an unprecedented rate as the baby boomer generation reaches retirement age. Aging-in-place (i.e. aging at home) is the desire of most seniors and is also a good option to reduce the burden on an over-stretched long-term-care system. Personal Emergency Response Systems (PERSs) help enable older adults to age-in-place by providing them with immediate access to emergency assistance. Traditionally they operate with push-button activators that connect the occupant via speaker-phone to a live emergency call-centre operator. If occupants do not wear the push button or cannot access the button, then the system is useless in the event of a fall or emergency. Additionally, a false alarm or failure to check-in at a regular interval will trigger a connection to a live operator, which can be unwanted and intrusive to the occupant. This paper describes the development and testing of an automated, hands-free, dialogue-based PERS prototype. Methods The prototype system was built using a ceiling mounted microphone array, an open-source automatic speech recognition engine, and a 'yes' and 'no' response dialog modelled after an existing call-centre protocol. Testing compared a single microphone versus a microphone array with nine adults in both noisy and quiet conditions. Dialogue testing was completed with four adults. Results and discussion The microphone array demonstrated improvement over the single microphone. In all cases, dialog testing resulted in the system reaching the correct decision about the kind of assistance the user was requesting. Further testing is required with elderly voices and under different noise conditions to ensure the appropriateness of the technology. Future developments include integration of the system with an emergency detection method as well as communication enhancement using features such as barge-in capability. Conclusion The use of an automated dialog-based PERS has the potential to provide users with more autonomy in decisions regarding their own health and more privacy in their own home. PMID:19583876

  8. Electrostatic dust collectors compared to inhalable samplers for measuring endotoxin concentrations in farm homes.

    PubMed

    Kilburg-Basnyat, B; Peters, T M; Perry, S S; Thorne, P S

    2016-10-01

    Paired electrostatic dust collectors (EDCs) and daily, inhalable button samplers (BS) were used concurrently to sample endotoxin in 10 farm homes during 7-day periods in summer and winter. Winter sampling included an optical particle counter (OPC) to measure PM2.5 and PM2.5-10 . Electrostatic dust collectors and BS filters were analyzed for endotoxin using the kinetic chromogenic Limulus amebocyte lysate assay. Optical particle counter particulate matter (PM) data were divided into two PM categories. In summer, geometric mean (geometric standard deviation) endotoxin concentrations were 0.82 EU/m(3) (2.7) measured with the BS and 737 EU/m(2) (1.9) measured with the EDC. Winter values were 0.52 EU/m(3) (3.1) for BS and 538 EU/m(2) (3.0) for EDCs. Seven-day endotoxin values of EDCs were highly correlated with the 7-day BS sampling averages (r = 0.70; P < 0.001). Analysis of variance indicated a 2.4-fold increase in EDC endotoxin concentrations for each unit increase of the ratio of PM2.5 to PM2.5-10 . There was also a significant correlation between BS and EDCs endotoxin concentrations for winter (r = 0.67; P < 0.05) and summer (r = 0.75; P < 0.05). Thus, EDCs sample comparable endotoxin concentrations to BS, making EDCs a feasible, easy to use alternative to BS for endotoxin sampling. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. BPM Button Optimization to Minimize Distortion Due to Trapped Mode Heating

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cameron,P.; Blednyk, A.; Kosciuk, B.

    2009-05-04

    The outer circumference of a BPM button and the inner circumference of the button housing comprise a transmission line. This transmission line typically presents an impedance of a few tens of ohms to the beam, and couples very weakly to the 50 ohm coaxial transmission line that comprises the signal path out of the button. The modes which are consequently excited and trapped often have quality factors of several hundred, permitting resonant excitation by the beam. The thermal distortion resulting from trapped mode heating is potentially problematic for achieving the high precision beam position measurements needed to provide the sub-micronmore » beam position stability required by light source users. We present a button design that has been optimized via material selection and component geometry to minimize both the trapped mode heating and the resulting thermal distortion.« less

  10. Dust exposure in workers from grain storage facilities in Costa Rica.

    PubMed

    Rodríguez-Zamora, María G; Medina-Escobar, Lourdes; Mora, Glend; Zock, Jan-Paul; van Wendel de Joode, Berna; Mora, Ana M

    2017-08-01

    About 12 million workers are involved in the production of basic grains in Central America. However, few studies in the region have examined the occupational factors associated with inhalable dust exposure. (i) To assess the exposure to inhalable dust in workers from rice, maize, and wheat storage facilities in Costa Rica; (ii) to examine the occupational factors associated with this exposure; and (iii) to measure concentrations of respirable and thoracic particles in different areas of the storage facilities. We measured inhalable (<100μm) dust concentrations in 176 personal samples collected from 136 workers of eight grain storage facilities in Costa Rica. We also measured respirable (<4μm) and thoracic (<10μm) dust particles in several areas of the storage facilities. Geometric mean (GM) and geometric standard deviation (GSD) inhalable dust concentrations were 2.0mg/m 3 and 7.8 (range=<0.2-275.4mg/m 3 ). Personal inhalable dust concentrations were associated with job category [GM for category/GM for administrative staff and other workers (95% CI)=4.4 (2.6, 7.2) for packing; 20.4 (12.3, 34.7) for dehulling; 109.6 (50.1, 234.4) for unloading in flat bed sheds; 24.0 (14.5, 39.8) for unloading in pits; and 31.6 (18.6, 52.5) for drying], and cleaning task [15.8 (95% CI: 10.0, 26.3) in workers who cleaned in addition to their regular tasks]. Higher area concentrations of thoracic dust particles were found in wheat (GM and GSD=4.3mg/m 3 and 4.5) and maize (3.0mg/m 3 and 3.9) storage facilities, and in grain drying (2.3mg/m 3 and 3.1) and unloading (1.5mg/m 3 and 4.8) areas. Operators of grain storage facilities showed elevated inhalable dust concentrations, mostly above international exposure limits. Better engineering and administrative controls are needed. Copyright © 2017 Elsevier GmbH. All rights reserved.

  11. Esophageal button battery ingestions: decreasing time to operative intervention by level I trauma activation.

    PubMed

    Russell, Robert T; Griffin, Russell L; Weinstein, Elizabeth; Billmire, Deborah F

    2014-09-01

    The incidence of button battery ingestions is increasing and injury due to esophageal impaction begins within minutes of exposure. We changed our management algorithm for suspected button battery ingestions with intent to reduce time to evaluation and operative removal. A retrospective study was performed to identify and evaluate time to treatment and outcome for all esophageal button battery ingestions presenting to a major children's hospital emergency room from February 1, 2010 through February 1, 2012. During the first year, standard emergency room triage (ST) was used. During the second year, the triage protocol was changed and Trauma I triage (TT) was used. 24 children had suspected button battery ingestions with 11 having esophageal impaction. One esophageal impaction was due to 2 stacked coins. Time from arrival in emergency room to battery removal was 183minutes in ST group (n=4) and 33minutes in TT group (n=7) (p=0.04). One patient in ST developed a tracheoesophageal fistula. There were no complications in the TT group. The use of Trauma 1 activations for suspected button battery ingestions has led to more expedient evaluation and shortened time to removal of impacted esophageal batteries. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Evaluation of Cognitive Function of Children with Developmental Disabilities by means of Button-Press Task

    NASA Astrophysics Data System (ADS)

    Nakazono, Shogo; Kobori, Satoshi

    The button-press task means that the subject observes a moving target and presses a button to stop it when the target enters a specified area on a computer display. Subjects perform normal task, suppressed task and delayed task. In the suppressed task, the moving target disappears at some point during the trial. In the delayed task, there is some lag time between the time of pressing button and of stopping target. In these tasks, subjects estimate the movement of the target, and press the button considering his/her own reaction time. In our previous study, we showed that cognitive and motor function was able to be evaluated by these tasks. In this study, we examined error data of children with developmental disabilities to evaluate the cognitive function, and investigated the learning processes. Moreover, we discussed the developmental stages by comparing the children with disabilities to normal control children, and we clarified the behavior characteristics of children with developmental disabilities. Asa result, it was shown that our evaluation method and system for the button-press task were effective to evaluate cognitive ability of children with developmental disabilities.

  13. Acromioclavicular joint dislocation: a Dog Bone button fixation alone versus Dog Bone button fixation augmented with acromioclavicular repair-a finite element analysis study.

    PubMed

    Sumanont, Sermsak; Nopamassiri, Supachoke; Boonrod, Artit; Apiwatanakul, Punyawat; Boonrod, Arunnit; Phornphutkul, Chanakarn

    2018-03-20

    Suspension suture button fixation was frequently used to treat acromioclavicular joint (ACJ) dislocation. However, there were many studies reporting about complications and residual horizontal instability after fixation. Our study compared the stability of ACJ after fixation between coracoclavicular (CC) fixation alone and CC fixation combined with ACJ repair by using finite element analysis (FEA). A finite element model was created by using CT images from the normal shoulder. The model 1 was CC fixation with suture button alone, and the model 2 was CC fixation with suture button combined with ACJ repair. Three different forces (50, 100, 200 N) applied to the model in three planes; inferior, anterior and posterior direction load to the acromion. The von Mises stress of the implants and deformation at ACJs was recorded. The ACJ repair in the model 2 could reduce the peak stress on the implant after applying the loading forces to the acromion which the ACJ repair could reduce the peak stress of the FiberWire at suture button about 90% when compared to model 1. And, the ACJ repair could reduce the deformation of the ACJ after applying the loading forces to the acromion in both vertical and horizontal planes. This FEA supports that the high-grade injuries of the ACJ should be treated with CC fixation combined with ACJ repair because this technique provides excellent stability in both vertical and horizontal planes and reduces stress to the suture button.

  14. An Exploratory Study on a Chest-Worn Computer for Evaluation of Diet, Physical Activity and Lifestyle

    PubMed Central

    Sun, Mingui; Burke, Lora E.; Baranowski, Thomas; Fernstrom, John D.; Zhang, Hong; Chen, Hsin-Chen; Bai, Yicheng; Li, Yuecheng; Li, Chengliu; Yue, Yaofeng; Li, Zhen; Nie, Jie; Sclabassi, Robert J.; Mao, Zhi-Hong; Jia, Wenyan

    2015-01-01

    Recently, wearable computers have become new members in the family of mobile electronic devices, adding new functions to those provided by smartphones and tablets. As “always-on” miniature computers in the personal space, they will play increasing roles in the field of healthcare. In this work, we present our development of eButton, a wearable computer designed as a personalized, attractive, and convenient chest pin in a circular shape. It contains a powerful microprocessor, numerous electronic sensors, and wireless communication links. We describe its design concepts, electronic hardware, data processing algorithms, and its applications to the evaluation of diet, physical activity and lifestyle in the study of obesity and other chronic diseases. PMID:25708374

  15. An exploratory study on a chest-worn computer for evaluation of diet, physical activity and lifestyle.

    PubMed

    Sun, Mingui; Burke, Lora E; Baranowski, Thomas; Fernstrom, John D; Zhang, Hong; Chen, Hsin-Chen; Bai, Yicheng; Li, Yuecheng; Li, Chengliu; Yue, Yaofeng; Li, Zhen; Nie, Jie; Sclabassi, Robert J; Mao, Zhi-Hong; Jia, Wenyan

    2015-01-01

    Recently, wearable computers have become new members in the family of mobile electronic devices, adding new functions to those provided by smart-phones and tablets. As "always-on" miniature computers in the personal space, they will play increasing roles in the field of healthcare. In this work, we present our development of eButton, a wearable computer designed as a personalized, attractive, and convenient chest pin in a circular shape. It contains a powerful microprocessor, numerous electronic sensors, and wireless communication links. We describe its design concepts, electronic hardware, data processing algorithms, and its applications to the evaluation of diet, physical activity and lifestyle in the study of obesity and other chronic diseases.

  16. An Acoustic-Based Method to Detect and Quantify the Effect of Exhalation into a Dry Powder Inhaler.

    PubMed

    Holmes, Martin S; Seheult, Jansen N; O'Connell, Peter; D'Arcy, Shona; Ehrhardt, Carsten; Healy, Anne Marie; Costello, Richard W; Reilly, Richard B

    2015-08-01

    Dry powder inhaler (DPI) users frequently exhale into their inhaler mouthpiece before the inhalation step. This error in technique compromises the integrity of the drug and results in poor bronchodilation. This study investigated the effect of four exhalation factors (exhalation flow rate, distance from mouth to inhaler, exhalation duration, and relative air humidity) on dry powder dose delivery. Given that acoustic energy can be related to the factors associated with exhalation sounds, we then aimed to develop a method of identifying and quantifying this critical inhaler technique error using acoustic based methods. An in vitro test rig was developed to simulate this critical error. The effect of the four factors on subsequent drug delivery were investigated using multivariate regression models. In a further study we then used an acoustic monitoring device to unobtrusively record the sounds 22 asthmatic patients made whilst using a Diskus(™) DPI. Acoustic energy was employed to automatically detect and analyze exhalation events in the audio files. All exhalation factors had a statistically significant effect on drug delivery (p<0.05); distance from the inhaler mouthpiece had the largest effect size. Humid air exhalations were found to reduce the fine particle fraction (FPF) compared to dry air. In a dataset of 110 audio files from 22 asthmatic patients, the acoustic method detected exhalations with an accuracy of 89.1%. We were able to classify exhalations occurring 5 cm or less in the direction of the inhaler mouthpiece or recording device with a sensitivity of 72.2% and specificity of 85.7%. Exhaling into a DPI has a significant detrimental effect. Acoustic based methods can be employed to objectively detect and analyze exhalations during inhaler use, thus providing a method of remotely monitoring inhaler technique and providing personalized inhaler technique feedback.

  17. Low-Cost Avoidance Behaviors are Resistant to Fear Extinction in Humans

    PubMed Central

    Vervliet, Bram; Indekeu, Ellen

    2015-01-01

    Elevated levels of fear and avoidance are core symptoms across the anxiety disorders. It has long been known that fear serves to motivate avoidance. Consequently, fear extinction has been the primary focus in pre-clinical anxiety research for decades, under the implicit assumption that removing the motivator of avoidance (fear) would automatically mitigate the avoidance behaviors as well. Although this assumption has intuitive appeal, it has received little scientific scrutiny. The scarce evidence from animal studies is mixed, while the assumption remains untested in humans. The current study applied an avoidance conditioning protocol in humans to investigate the effects of fear extinction on the persistence of low-cost avoidance. Online danger-safety ratings and skin conductance responses documented the dynamics of conditioned fear across avoidance and extinction phases. Anxiety- and avoidance-related questionnaires explored individual differences in rates of avoidance. Participants first learned to click a button during a predictive danger signal, in order to cancel an upcoming aversive electrical shock (avoidance conditioning). Next, fear extinction was induced by presenting the signal in the absence of shocks while button-clicks were prevented (by removing the button in Experiment 1, or by instructing not to click the button in Experiment 2). Most importantly, post-extinction availability of the button caused a significant return of avoidant button-clicks. In addition, trait-anxiety levels correlated positively with rates of avoidance during a predictive safety signal, and with the rate of pre- to post-extinction decrease during this signal. Fear measures gradually decreased during avoidance conditioning, as participants learned that button-clicks effectively canceled the shock. Preventing button-clicks elicited a sharp increase in fear, which subsequently extinguished. Fear remained low during avoidance testing, but danger-safety ratings increased again when button-clicks were subsequently prevented. Together, these results show that low-cost avoidance behaviors can persist following fear extinction and induce increased threat appraisal. On the other hand, fear extinction did reduce augmented rates of unnecessary avoidance during safety in trait-anxious individuals, and instruction-based response prevention was more effective than removal of response cues. More research is needed to characterize the conditions under which fear extinction might mitigate avoidance. PMID:26733837

  18. Effect of novel inhaler technique reminder labels on the retention of inhaler technique skills in asthma: a single-blind randomized controlled trial.

    PubMed

    Basheti, Iman A; Obeidat, Nathir M; Reddel, Helen K

    2017-02-09

    Inhaler technique can be corrected with training, but skills drop off quickly without repeated training. The aim of our study was to explore the effect of novel inhaler technique labels on the retention of correct inhaler technique. In this single-blind randomized parallel-group active-controlled study, clinical pharmacists enrolled asthma patients using controller medication by Accuhaler [Diskus] or Turbuhaler. Inhaler technique was assessed using published checklists (score 0-9). Symptom control was assessed by asthma control test. Patients were randomized into active (ACCa; THa) and control (ACCc; THc) groups. All patients received a "Show-and-Tell" inhaler technique counseling service. Active patients also received inhaler labels highlighting their initial errors. Baseline data were available for 95 patients, 68% females, mean age 44.9 (SD 15.2) years. Mean inhaler scores were ACCa:5.3 ± 1.0; THa:4.7 ± 0.9, ACCc:5.5 ± 1.1; THc:4.2 ± 1.0. Asthma was poorly controlled (mean ACT scores ACCa:13.9 ± 4.3; THa:12.1 ± 3.9; ACCc:12.7 ± 3.3; THc:14.3 ± 3.7). After training, all patients had correct technique (score 9/9). After 3 months, there was significantly less decline in inhaler technique scores for active than control groups (mean difference: Accuhaler -1.04 (95% confidence interval -1.92, -0.16, P = 0.022); Turbuhaler -1.61 (-2.63, -0.59, P = 0.003). Symptom control improved significantly, with no significant difference between active and control patients, but active patients used less reliever medication (active 2.19 (SD 1.78) vs. control 3.42 (1.83) puffs/day, P = 0.002). After inhaler training, novel inhaler technique labels improve retention of correct inhaler technique skills with dry powder inhalers. Inhaler technique labels represent a simple, scalable intervention that has the potential to extend the benefit of inhaler training on asthma outcomes. REMINDER LABELS IMPROVE INHALER TECHNIQUE: Personalized labels on asthma inhalers remind patients of correct technique and help improve symptoms over time. Iman Basheti at the Applied Science Private University in Jordan and co-workers trialed the approach of placing patient-specific reminder labels on dry-powder asthma inhalers to improve long-term technique. Poor asthma control is often exacerbated by patients making mistakes when using their inhalers. During the trial, 95 patients received inhaler training before being split into two groups: the control group received no further help, while the other group received individualized labels on their inhalers reminding them of their initial errors. After three months, 67% of patients with reminder labels retained correct technique compared to only 12% of controls. They also required less reliever medication and reported improved symptoms. This represents a simple, cheap way of tackling inhaler technique errors.

  19. Long-term effects of aluminium dust inhalation.

    PubMed

    Peters, Susan; Reid, Alison; Fritschi, Lin; de Klerk, Nicholas; Musk, A W Bill

    2013-12-01

    During the 1950s and 1960s, aluminium dust inhalation was used as a potential prophylaxis against silicosis in underground miners, including in Australia. We investigated the association between aluminium dust inhalation and cardiovascular, cerebrovascular and Alzheimer's diseases in a cohort of Australian male underground gold miners. We additionally looked at pneumoconiosis mortality to estimate the effect of the aluminium therapy. SMRs and 95% CI were calculated to compare mortality of the cohort members with that of the Western Australian male population (1961-2009). Internal comparisons on duration of aluminium dust inhalation were examined using Cox regression. Aluminium dust inhalation was reported for 647 out of 1894 underground gold miners. During 42 780 person-years of follow-up, 1577 deaths were observed. An indication of increased mortality of Alzheimer's disease among miners ever exposed to aluminium dust was found (SMR=1.38), although it was not statistically significant (95% CI 0.69 to 2.75). Rates for cardiovascular and cerebrovascular death were above population levels, but were similar for subjects with or without a history of aluminium dust inhalation. HRs suggested an increasing risk of cardiovascular disease with duration of aluminium dust inhalation (HR=1.02, 95% CI 1.00 to 1.04, per year of exposure). No difference in the association between duration of work underground and pneumoconiosis was observed between the groups with or without aluminium dust exposure. No protective effect against silicosis was observed from aluminium dust inhalation. Conversely, exposure to aluminium dust may possibly increase the risk of cardiovascular disease and dementia of the Alzheimer's type.

  20. The Evolution of Pressurized Metered-Dose Inhalers from Early to Modern Devices.

    PubMed

    Roche, Nicolas; Dekhuijzen, P N Richard

    2016-08-01

    Pressurized metered-dose inhalers (pMDIs) are sometimes viewed as old-fashioned and as having been superseded by dry powder inhalers (DPIs). Here, we review the technological advances that characterize modern pMDIs, and consider how they can influence the effectiveness of drug delivery for patients with asthma and chronic obstructive pulmonary disease. Compared with old chlorofluorocarbon (CFC)-based inhalers, many hydrofluoroalkane (HFA)-driven pMDIs have more favorable plume characteristics such as a reduced velocity and a higher fine particle fraction; together, these advances have resulted in the development of pMDIs with reduced oropharyngeal deposition and increased lung deposition. In addition, the plume from many HFA-pMDIs is warmer, which may facilitate their use by patients; moreover, devices are equipped with dose counters, which improves their reliability. As well as reviewing the technological advances of pMDIs, we also discuss the importance of individualizing inhaler therapies to each patient by accounting for their personal preferences and natural breathing patterns. Because pMDIs and DPIs differ considerably in their handling characteristics, matching the right inhaler to the right patient is key to ensuring effective therapy and good compliance. Finally, the majority of patients can be trained successfully in the correct use of their pMDI; training and regular monitoring of inhalation technique are essential prerequisites for effective therapy. While the 'ideal inhaler' may not exist, pMDIs are an effective device option suitable for many patients. pMDIs, together with other types of devices, offer opportunities for the effective individualization of treatments.

  1. Population pharmacokinetics of caffeine and its metabolites theobromine, paraxanthine and theophylline after inhalation in combination with diacetylmorphine.

    PubMed

    Zandvliet, Anthe S; Huitema, Alwin D R; de Jonge, Milly E; den Hoed, Rob; Sparidans, Rolf W; Hendriks, Vincent M; van den Brink, Wim; van Ree, Jan M; Beijnen, Jos H

    2005-01-01

    The stimulant effect of caffeine, as an additive in diacetylmorphine preparations for study purposes, may interfere with the pharmacodynamic effects of diacetylmorphine. In order to obtain insight into the pharmacology of caffeine after inhalation in heroin users, the pharmacokinetics of caffeine and its dimethylxanthine metabolites were studied. The objectives were to establish the population pharmacokinetics under these exceptional circumstances and to compare the results to published data regarding intravenous and oral administration in healthy volunteers. Diacetylmorphine preparations containing 100 mg of caffeine were used by 10 persons by inhalation. Plasma concentrations of caffeine, theobromine, paraxanthine and theophylline were measured by high performance liquid chromatography. Non-linear mixed effects modelling was used to estimate population pharmacokinetic parameters. The model was evaluated by the jack-knife procedure. Caffeine was rapidly and effectively absorbed after inhalation. Population pharmacokinetics of caffeine and its dimethylxanthine metabolites could adequately and simultaneously be described by a linear multi-compartment model. The volume of distribution for the central compartment was estimated to be 45.7 l and the apparent elimination rate constant of caffeine at 8 hr after inhalation was 0.150 hr(-1) for a typical individual. The bioavailability was approximately 60%. The presented model adequately describes the population pharmacokinetics of caffeine and its dimethylxanthine metabolites after inhalation of the caffeine sublimate of a 100 mg tablet. Validation proved the stability of the model. Pharmacokinetics of caffeine after inhalation and intravenous administration are to a large extent similar. The bioavailability of inhaled caffeine is approximately 60% in experienced smokers.

  2. Recognizing medical emergencies

    MedlinePlus

    ... persistent vomiting Sudden injury due to a motor vehicle accident, burns or smoke inhalation, near drowning, deep ... in case of a neck injury or motor vehicle accident) The person needs the skills or equipment ...

  3. Modeling the impact of pedestrian behavior diversity on traffic dynamics at a crosswalk with push button

    NASA Astrophysics Data System (ADS)

    Xie, Dong-Fan; Zhao, Xiao-Mei; Li, Xin-Gang; Zhu, Tai-Lang

    2016-01-01

    Crosswalk with push button is prevalent in lots of cities for the purpose of promoting the efficiency of the crosswalk, and thus the delays of both vehicles and pedestrians can be reduced. This strategy has been confirmed to be effective in several developed countries. However, it is a pity that application of push button is aborted in some cities in China. In this work, diverse behaviors of vehicles and pedestrians are analyzed and discussed. Then, a microscopic model is developed by incorporating the interaction between vehicles and pedestrians. Numerical simulations are performed to reveal the characteristics of traffic flow and the efficiency of the signal control strategy. Also, the impacts of risker proportion and button reaction time, as well as the impacts of various behaviors as mass behavior, the patience of pedestrian and push button habit are investigated. It is expected that the results will be helpful to the strategy design of a signalized crosswalk in such developing countries as China.

  4. Management of nasal septal perforation using silicone nasal septal button

    PubMed Central

    Mullace, M; Gorini, E; Sbrocca, M; Artesi, L; Mevio, N

    2006-01-01

    Summary Nasal septal perforation may present with various symptoms: epistaxis, crusting, secondary infection, whistling and nasal obstruction. Perforation may be treated by conservative pharmacological treatment or closed by surgical approach. A useful alternative is mechanical obturation, achieved inserting a prosthesis. The present report refers to a study on 15 patients (10 male, 5 female, mean age 38.5 years) treated by insertion of a one-piece or two-piece silicone septal button (Xomed). In the follow-up period, insertion of the nasal button reduced epistaxis, eliminated whistling during inspiration, and reduced nasal obstruction and crusting around the margin of the perforation. Contraindications are presence of acute infection with osteitis, chronic septal disease (Wegener), neoplasia and extremely large perforations. The latest buttons appear to be superior to the conventional type on account of plasticity and adaptability which offer greater conformity to the septum. This study also reveals that the new septal button is well tolerated by patients. PMID:18236638

  5. Delayed system response times affect immediate physiology and the dynamics of subsequent button press behavior.

    PubMed

    Kohrs, Christin; Hrabal, David; Angenstein, Nicole; Brechmann, André

    2014-11-01

    System response time research is an important issue in human-computer interactions. Experience with technical devices and general rules of human-human interactions determine the user's expectation, and any delay in system response time may lead to immediate physiological, emotional, and behavioral consequences. We investigated such effects on a trial-by-trial basis during a human-computer interaction by measuring changes in skin conductance (SC), heart rate (HR), and the dynamics of button press responses. We found an increase in SC and a deceleration of HR for all three delayed system response times (0.5, 1, 2 s). Moreover, the data on button press dynamics was highly informative since subjects repeated a button press with more force in response to delayed system response times. Furthermore, the button press dynamics could distinguish between correct and incorrect decisions and may thus even be used to infer the uncertainty of a user's decision. Copyright © 2014 Society for Psychophysiological Research.

  6. How to Use This Website | USDA Plant Hardiness Zone Map

    Science.gov Websites

    , regional or national plant hardiness zone maps in three different resolutions using the following steps. To default printing menu option or button. Viewing the Map - Open Full Map Button c. Save Full Map Button can copy the e-mail address and paste it into a different e-mail client (e.g., Google Gmail, Yahoo

  7. Esophageal button battery ingestion in children.

    PubMed

    Şencan, Arzu; Genişol, İncinur; Hoşgör, Münevver

    2017-07-01

    Button battery lodged in the esophagus carries a high risk of morbidity and mortality. The purpose of this study was to present cases of patients with esophageal button battery ingestion treated at our clinic and to emphasize the importance of early diagnosis and treatment. Records of patients admitted to our hospital for foreign body ingestion between January 2010 and May 2015 were retrospectively reviewed. Cases with button battery lodged in the esophagus were included in the study. Patient data regarding age, sex, length of time after ingestion until admission, presenting clinical symptoms, type and localization of the battery, management, and prognosis were analyzed. Among 1891 foreign body ingestions, 71 were localized in the esophagus, and 8 of those (11.2%) were cases of button battery ingestion. Mean age was 1.7 years. Admission was within 6 hours of ingestion in 5 cases, after 24 hours had elapsed in 2, and 1 month after ingestion in 1 case. All patients but 1 knew the history of ingestion. Prompt endoscopic removal was performed for all patients. Three patients developed esophageal stricture, which responded to dilatation. Early recognition and timely endoscopic removal is mandatory in esophageal button battery ingestion. It should be suspected in the differential diagnosis of patients with persistent respiratory and gastrointestinal symptoms.

  8. Thermocron iButton and iBBat temperature dataloggers emit ultrasound.

    PubMed

    Willis, Craig K R; Jameson, Joel W; Faure, Paul A; Boyles, Justin G; Brack, Virgil; Cervone, Tom H

    2009-10-01

    Thermocron iButton dataloggers are widely used to measure thermal microclimates experienced by wild animals. The iBBat is a smaller version of the datalogger, also commercially available, that is used to measure animal skin or core body temperatures when attached externally or surgically implanted. Field observations of bats roosting under a bridge suggested that bats avoided locations with iButtons. A heterodyne bat detector revealed that the dataloggers emitted ultrasound which was detectable from a distance of up to 30 cm. We therefore recorded and quantified the acoustic properties [carrier frequency (Hz) and root mean square sound pressure level (dB SPL)] of iButton and iBBat dataloggers. All units emitted a 32.9 kHz pure tone that was readily picked up with a time expansion bat detector at a distance of 1 cm, and most were detected at a distance of 15 cm. The maximum amplitude of iButton dataloggers was 46.5 dB SPL at 1.0 cm-a level within the range of auditory sensitivity for most small mammals. Wrapping iButtons in plastic insulation severely attenuated the amplitude of ultrasound. Although there was a statistically significant reduction in rates of warming and cooling with insulation, this effect was small and we suggest that insulation may be a viable solution to eliminate unwanted ultrasonic noise in instances when small delays in thermal response dynamics are not a concern. We recommend behavioural studies to assess if the electronic signals emitted by iButtons are disturbing to small mammals.

  9. Learning processes underlying avoidance of negative outcomes.

    PubMed

    Andreatta, Marta; Michelmann, Sebastian; Pauli, Paul; Hewig, Johannes

    2017-04-01

    Successful avoidance of a threatening event may negatively reinforce the behavior due to activation of brain structures involved in reward processing. Here, we further investigated the learning-related properties of avoidance using feedback-related negativity (FRN). The FRN is modulated by violations of an intended outcome (prediction error, PE), that is, the bigger the difference between intended and actual outcome, the larger the FRN amplitude is. Twenty-eight participants underwent an operant conditioning paradigm, in which a behavior (button press) allowed them to avoid a painful electric shock. During two learning blocks, participants could avoid an electric shock in 80% of the trials by pressing one button (avoidance button), or by not pressing another button (punishment button). After learning, participants underwent two test blocks, which were identical to the learning ones except that no shocks were delivered. Participants pressed the avoidance button more often than the punishment button. Importantly, response frequency increased throughout the learning blocks but it did not decrease during the test blocks, indicating impaired extinction and/or habit formation. In line with a PE account, FRN amplitude to negative feedback after correct responses (i.e., unexpected punishment) was significantly larger than to positive feedback (i.e., expected omission of punishment), and it increased throughout the blocks. Highly anxious individuals showed equal FRN amplitudes to negative and positive feedback, suggesting impaired discrimination. These results confirm the role of negative reinforcement in motivating behavior and learning, and reveal important differences between high and low anxious individuals in the processing of prediction errors. © 2017 Society for Psychophysiological Research.

  10. Inhalation TTC values: A new integrative grouping approach considering structural, toxicological and mechanistic features.

    PubMed

    Tluczkiewicz, I; Kühne, R; Ebert, R-U; Batke, M; Schüürmann, G; Mangelsdorf, I; Escher, S E

    2016-07-01

    The present publication describes an integrative grouping concept to derive threshold values for inhalation exposure. The classification scheme starts with differences in toxicological potency and develops criteria to group compounds into two potency classes, namely toxic (T-group) or low toxic (L-group). The TTC concept for inhalation exposure is based on the TTC RepDose data set, consisting of 296 organic compounds with 608 repeated-dose inhalation studies. Initially, 21 structural features (SFs) were identified as being characteristic for compounds of either high or low NOEC values (Schüürmann et al., 2016). In subsequent analyses these SF groups were further refined by taking into account structural homogeneity, type of toxicological effect observed, differences in absorption, metabolism and mechanism of action (MoA), to better define their structural and toxicological boundaries. Differentiation of a local or systemic mode of action did not improve the classification scheme. Finally, 28 groups were discriminated: 19 T-groups and 9 L-groups. Clearly distinct thresholds were derived for the T- and L-toxicity groups, being 2 × 10(-5) ppm (2 μg/person/day) and 0.05 ppm (4260 μg/person/day), respectively. The derived thresholds and the classification are compared to the initial mainly structure driven grouping (Schüürmann et al., 2016) and to the Cramer classification. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Serious complications after button battery ingestion in children.

    PubMed

    Krom, Hilde; Visser, Margot; Hulst, Jessie M; Wolters, Victorien M; Van den Neucker, Anita M; de Meij, Tim; van der Doef, Hubert P J; Norbruis, Obbe F; Benninga, Marc A; Smit, Margot J M; Kindermann, Angelika

    2018-07-01

    Serious and fatal complications after button battery ingestion are increasing worldwide. The aim of this study is to describe serious complications after battery ingestion in children in the Netherlands.All pediatric gastroenterologists in the Netherlands performing upper endoscopies were asked to report all serious complications after battery ingestion in children (0-18 years) between 2008 and 2016 retrospectively.Sixteen serious complications were reported: death after massive bleeding through esophageal-aortal fistula (n = 1), esophageal-tracheal fistula (n = 5), stenosis after (suspected) perforation and mediastinitis (n = 5), (suspected) perforation and mediastinitis (n = 3), vocal cord paralysis (n = 1), and required reintubation for dyspnea and stridor (n = 1). The median time interval between ingestion and presentation was 5 (IQR 2-258) h. All children were ≤ 5 (median 1.4; IQR 0.9-2.1) years. Vomiting (31.3%), swallowing/feeding problems (31.3%), and fever (31.3%) were the most common presenting symptoms; however, 18.8% of the patients were asymptomatic (n = 1 missing). All batteries were button batteries (75% ≥ 20 mm; 18.8% < 20 mm; n = 1 missing). The batteries were removed by esophagogastroduodenoscopy (50%) and rigid endoscopy (37.5%) or surgically (12.5%). Sixteen serious complications occurred after small and large button batteries ingestion between 2008 and 2016 in both symptomatic and asymptomatic children in the Netherlands. Therefore, immediate intervention after (suspected) button battery ingestion is required. What is Known: • Button battery ingestion may result in serious and fatal complications. • Serious and fatal complications after button battery ingestion are increasing worldwide. What is New: • Sixteen serious complications after button battery ingestion occurred during 2008-2016 in children in the Netherlands. • Serious complications were also caused by small batteries (< 20 mm) in the Netherlands and also occurred in asymptomatic Dutch children.

  12. A pilot study of personal exposure to respirable and inhalable dust during the sanding and sawing of medium density fibreboard (MDF) and soft wood.

    PubMed

    Hursthouse, Andrew; Allan, Fraser; Rowley, Louise; Smith, Frank

    2004-08-01

    A pilot study of production of respirable and inhalable dusts from sawing and sanding medium density fibreboard (MDF) and softwood in a typical cabinet-making workshop produced high but variable exposure levels at the bench and operator position. Exposure levels for the total inhalable fraction (approximately <100 microm) were 6.9-91 mg m(-3) for MDF and 2.5-45 mg m(-3) for softwood. For the respirable fraction (< 10 microm) levels were 0.4-13 mg m(-3) for MDF and 0.4-2.9 mg m(-3) for softwood. These results show significant dust loading is produced in the coarser fraction and that the material used has a significant impact on levels produced. It suggests that fuller evaluation of operator influence of fine dust production is needed and may question the common application of a single inhalable exposure standard for wood dust to all wood working scenarios.

  13. Learn about Nontuberculous Mycobacteria (NTM)

    MedlinePlus

    ... are naturally-occurring organisms found in water and soil. NTM lung infection occurs when a person inhales ... Nontuberculous mycobacteria (NTM) are organisms naturally found in soil and water. NTM infections can become chronic and ...

  14. Dazomet Fumigant Safe Handling Guide

    EPA Pesticide Factsheets

    Dazomet is the active ingredient in Basamid G soil fumigant pesticide. Wear personal protective equipment such as respirators when handling Basamid granules or making an application, mitigate exposures, and recognize signs of vapor inhalation.

  15. Possible Exposure Pathways During Emergencies

    EPA Pesticide Factsheets

    There are three basic ways a person may be exposed to a hazardous substance: inhalation, ingestion, or direct contact. Points of contact include groundwater or surface water; soil, sediment, or dust; air; or food.

  16. A PC parallel port button box provides millisecond response time accuracy under Linux.

    PubMed

    Stewart, Neil

    2006-02-01

    For psychologists, it is sometimes necessary to measure people's reaction times to the nearest millisecond. This article describes how to use the PC parallel port to receive signals from a button box to achieve millisecond response time accuracy. The workings of the parallel port, the corresponding port addresses, and a simple Linux program for controlling the port are described. A test of the speed and reliability of button box signal detection is reported. If the reader is moderately familiar with Linux, this article should provide sufficient instruction for him or her to build and test his or her own parallel port button box. This article also describes how the parallel port could be used to control an external apparatus.

  17. A comparison of portable XRF and ICP-OES analysis for lead on air filter samples from a lead ore concentrator mill and a lead-acid battery recycler.

    PubMed

    Harper, Martin; Pacolay, Bruce; Hintz, Patrick; Andrew, Michael E

    2006-03-01

    Personal and area samples for airborne lead were taken at a lead mine concentrator mill, and at a lead-acid battery recycler. Lead is mined as its sulfidic ore, galena, which is often associated with zinc and silver. The ore typically is concentrated, and partially separated, on site by crushing and differential froth flotation of the ore minerals before being sent to a primary smelter. Besides lead, zinc and iron are also present in the airborne dusts, together with insignificant levels of copper and silver, and, in one area, manganese. The disposal of used lead-acid batteries presents environmental issues, and is also a waste of recoverable materials. Recycling operations allow for the recovery of lead, which can then be sold back to battery manufacturers to form a closed loop. At the recycling facility lead is the chief airborne metal, together with minor antimony and tin, but several other metals are generally present in much smaller quantities, including copper, chromium, manganese and cadmium. Samplers used in these studies included the closed-face 37 mm filter cassette (the current US standard method for lead sampling), the 37 mm GSP or "cone" sampler, the 25 mm Institute of Occupational Medicine (IOM) inhalable sampler, the 25 mm Button sampler, and the open-face 25 mm cassette. Mixed cellulose-ester filters were used in all samplers. The filters were analyzed after sampling for their content of the various metals, particularly lead, that could be analyzed by the specific portable X-ray fluorescence (XRF) analyzer under study, and then were extracted with acid and analyzed by inductively coupled plasma optical emission spectroscopy (ICP-OES). The 25 mm filters were analyzed using a single XRF reading, while three readings on different parts of the filter were taken from the 37 mm filters. For lead at the mine concentrate mill, all five samplers gave good correlations (r2 > 0.96) between the two analytical methods over the entire range of found lead mass, which encompassed the permissible exposure limit of 150 mg m(-3) enforced in the USA by the Mine Safety and Health Administration (MSHA). Linear regression on the results from most samplers gave almost 1 ratio 1 correlations without additional correction, indicating an absence of matrix effects from the presence of iron and zinc in the samples. An approximately 10% negative bias was found for the slope of the Button sampler regression, in line with other studies, but it did not significantly affect the accuracy as all XRF results from this sampler were within 20% of the corresponding ICP values. As in previous studies, the best results were obtained with the GSP sampler using the average of three readings, with all XRF results within 20% of the corresponding ICP values and a slope close to 1 (0.99). Greater than 95% of XRF results were within 20% of the corresponding ICP values for the closed-face 37 mm cassette using the OSHA algorithm, and the IOM sampler using a sample area of 3.46 cm2. As in previous studies, considerable material was found on the interior walls of all samplers that possess an internal surface for deposition, at approximately the same proportion for all samplers. At the lead-acid battery recycler all five samplers in their optimal configurations gave good correlations (r2 > 0.92) between the two analytical methods over the entire range of found lead mass, which included the permissible exposure limit enforced in the USA by the Occupational Safety and Health Administration (OSHA). Linear regression on the results from most samplers gave almost 1 ratio 1 correlations (except for the Button sampler), indicating an absence of matrix effects from the presence of the smaller quantities of the other metals in the samples. A negative bias was found for the slope of the button sampler regression, in line with other studies. Even though very high concentrations of lead were encountered (up to almost 6 mg m(-3)) no saturation of the detector was observed. Most samplers performed well, with >90% of XRF results within +/- 25% of the corresponding ICP results for the optimum configurations. The OSHA algorithm for the CFC worked best without including the back-up pad with the filter.

  18. The efficacies of pure LICAM(C) and DTPA for enhancing the elimination of plutonium-238 and americium-241 from rats after their inhalation as nitrate.

    PubMed

    Stradling, G N; Stather, J W; Gray, S A; Moody, J C; Ellender, M; Hodgson, A

    1989-01-01

    After the inhalation of 238Pu and 241Am as nitrate, the repeated administration of DTPA is far superior to that of LICAM(C) for enhancing their elimination from the body. The therapeutic efficacies of these chelating agents are however similar after intravenous injection of 238Pu as citrate. It is concluded that DTPA should remain the agent of choice for treating persons contaminated internally with transportable forms of these actinides.

  19. A Jungle in There: Bacteria in Belly Buttons are Highly Diverse, but Predictable

    PubMed Central

    Hulcr, Jiri; Latimer, Andrew M.; Henley, Jessica B.; Rountree, Nina R.; Fierer, Noah; Lucky, Andrea; Lowman, Margaret D.; Dunn, Robert R.

    2012-01-01

    The belly button is one of the habitats closest to us, and yet it remains relatively unexplored. We analyzed bacteria and arachaea from the belly buttons of humans from two different populations sampled within a nation-wide citizen science project. We examined bacterial and archaeal phylotypes present and their diversity using multiplex pyrosequencing of 16S rDNA libraries. We then tested the oligarchy hypothesis borrowed from tropical macroecology, namely that the frequency of phylotypes in one sample of humans predicts its frequency in another independent sample. We also tested the predictions that frequent phylotypes (the oligarchs) tend to be common when present, and tend to be more phylogenetically clustered than rare phylotypes. Once rarefied to four hundred reads per sample, bacterial communities from belly buttons proved to be at least as diverse as communities known from other skin studies (on average 67 bacterial phylotypes per belly button). However, the belly button communities were strongly dominated by a few taxa: only 6 phylotypes occurred on >80% humans. While these frequent bacterial phylotypes (the archaea were all rare) are a tiny part of the total diversity of bacteria in human navels (<0.3% of phylotypes), they constitute a major portion of individual reads (∼1/3), and are predictable among independent samples of humans, in terms of both the occurrence and evolutionary relatedness (more closely related than randomly drawn equal sets of phylotypes). Thus, the hypothesis that “oligarchs” dominate diverse assemblages appears to be supported by human-associated bacteria. Although it remains difficult to predict which species of bacteria might be found on a particular human, predicting which species are most frequent (or rare) seems more straightforward, at least for those species living in belly buttons. PMID:23144827

  20. Comparative assessment of button cells using a normalized index for potential pollution by heavy metals.

    PubMed

    Moreno-Merino, Luis; Jiménez-Hernández, Maria Emilia; de la Losa, Almudena; Huerta-Muñoz, Virginia

    2015-09-01

    Many household batteries worldwide still end up in landfills or are incinerated due to inefficient collection and recycling schemes. Toxic heavy metals from improperly discarded button cells pose a serious risk to human health and the environment, as they can pollute air, soil and water. This paper analyses a series of button cells selected from batteries available on the retail market, and compares their polluting potential. A total of 64 batteries were subjected to chemical analyses of 19 elements - including metals and metalloids - , and energy density measurements. The samples were from four different brands of each of the four most common button cell technologies (alkaline, zinc-air, silver oxide and lithium). An energy-normalized index - the Weighted Potential Pollution Index (WPPI) - was proposed to compare the polluting potential of the different batteries. The higher the battery WPPI score, the greater the content in toxic elements and the lower the energy output. The results of the chemical composition and energy density varied depending on the construction technology of the button cells. However, significant differences in both variables were also found when comparing different brands within the same technology. The differences in WPPI values confirmed the existence of a significant margin to reduce the environmental impact of discarded button cells simply by avoiding the most polluting options. The choice of the battery with the most favourable WPPI produced a reduction in potential pollution of 3-53% for silver oxide batteries, 4-39% for alkaline, 20-28% for zinc-air and 12-26% for lithium. Comparative potential pollution could be assessed when selecting batteries using an energy-normalized index such as WPPI to reduce the environmental impact of improperly disposed button cells. Published by Elsevier B.V.

  1. SurveyWiz and factorWiz: JavaScript Web pages that make HTML forms for research on the Internet.

    PubMed

    Birnbaum, M H

    2000-05-01

    SurveyWiz and factorWiz are Web pages that act as wizards to create HTML forms that enable one to collect data via the Web. SurveyWiz allows the user to enter survey questions or personality test items with a mixture of text boxes and scales of radio buttons. One can add demographic questions of age, sex, education, and nationality with the push of a button. FactorWiz creates the HTML for within-subjects, two-factor designs as large as 9 x 9, or higher order factorial designs up to 81 cells. The user enters levels of the row and column factors, which can be text, images, or other multimedia. FactorWiz generates the stimulus combinations, randomizes their order, and creates the page. In both programs HTML is displayed in a window, and the user copies it to a text editor to save it. When uploaded to a Web server and supported by a CGI script, the created Web pages allow data to be collected, coded, and saved on the server. These programs are intended to assist researchers and students in quickly creating studies that can be administered via the Web.

  2. Sensory Feedback Training for Improvement of Finger Perception in Cerebral Palsy

    PubMed Central

    Alves-Pinto, Ana; Aschmann, Simon; Lützow, Ines; Lampe, Renée

    2015-01-01

    Purpose. To develop and to test a feedback training system for improvement of tactile perception and coordination of fingers in children and youth with cerebral palsy. Methods. The fingers of 7 probands with cerebral palsy of different types and severity were stimulated using small vibration motors integrated in the fingers of a hand glove. The vibration motors were connected through a microcontroller to a computer and to a response 5-button keyboard. By pressing an appropriate keyboard button, the proband must indicate in which finger the vibration was felt. The number of incorrect responses and the reaction time were measured for every finger. The perception and coordination of fingers were estimated before and after two-week training using both clinical tests and the measurements. Results. Proper functioning of the developed system in persons with cerebral palsy was confirmed. The tactile sensation of fingers was improved in five of seven subjects after two weeks of training. There was no clear tendency towards improvement of selective use of fingers. Conclusion. The designed feedback system could be used to train tactile perception of fingers in children and youth with cerebral palsy. An extensive study is required to confirm these findings. PMID:26124965

  3. Sensory Feedback Training for Improvement of Finger Perception in Cerebral Palsy.

    PubMed

    Blumenstein, Tobias; Alves-Pinto, Ana; Turova, Varvara; Aschmann, Simon; Lützow, Ines; Lampe, Renée

    2015-01-01

    Purpose. To develop and to test a feedback training system for improvement of tactile perception and coordination of fingers in children and youth with cerebral palsy. Methods. The fingers of 7 probands with cerebral palsy of different types and severity were stimulated using small vibration motors integrated in the fingers of a hand glove. The vibration motors were connected through a microcontroller to a computer and to a response 5-button keyboard. By pressing an appropriate keyboard button, the proband must indicate in which finger the vibration was felt. The number of incorrect responses and the reaction time were measured for every finger. The perception and coordination of fingers were estimated before and after two-week training using both clinical tests and the measurements. Results. Proper functioning of the developed system in persons with cerebral palsy was confirmed. The tactile sensation of fingers was improved in five of seven subjects after two weeks of training. There was no clear tendency towards improvement of selective use of fingers. Conclusion. The designed feedback system could be used to train tactile perception of fingers in children and youth with cerebral palsy. An extensive study is required to confirm these findings.

  4. Exploring Virtual Worlds with Head-Mounted Displays

    DTIC Science & Technology

    1989-02-01

    docking problem is important both to biochemists attempting to understand how proteins and nucleic acids work, and to chemists doing analytic drug design...then depressing the mouse button he is able to manipulate the methotrexate. A. long as the mouse button is depressed the methotrexate will follow the... depressing the mouse button outside of the drug’s "grabbing" volume. In this mode, both molecules move in concert. When the active site is positioned to

  5. Identifying predictive factors for long-term complications following button battery impactions: A case series and literature review.

    PubMed

    Eliason, Michael J; Melzer, Jonathan M; Winters, Jessica R; Gallagher, Thomas Q

    2016-08-01

    To complement a case series review of button battery impactions managed at our single military tertiary care center with a thorough literature review of laboratory research and clinical cases to develop a protocol to optimize patient care. Specifically, to identify predictive factors of long-term complications which can be used by the pediatric otolaryngologist to guide patient management after button battery impactions. A retrospective review of the Department of Defense's electronic medical record systems was conducted to identify patients with button battery ingestions and then characterize their treatment course. A thorough literature review complemented the lessons learned to identify potentially predictive clinical measures for long-term complications. Eight patients were identified as being treated for button battery impaction in the aerodigestive tract with two sustaining long-term complications. The median age of the patients treated was 33 months old and the median estimated time of impaction in the aerodigestive tract prior to removal was 10.5 h. Time of impaction, anatomic direction of the battery's negative pole, and identifying specific battery parameters were identified as factors that may be employed to predict sequelae. Based on case reviews, advancements in battery manufacturing, and laboratory research, there are distinct clinical factors that should be assessed at the time of initial therapy to guide follow-up management to minimize potential catastrophic sequelae of button battery ingestion. Published by Elsevier Ireland Ltd.

  6. Exposure to biohazards in wood dust: bacteria, fungi, endotoxins, and (1-->3)-beta-D-glucans.

    PubMed

    Alwis, K U; Mandryk, J; Hocking, A D

    1999-09-01

    Personal exposure to fungi, bacteria, endotoxin, and (1-->3)-beta-D-glucan was determined at different woodworking sites--logging sites, sawmills, woodchipping sites, and joineries. Exposure levels to fungi at logging sites and sawmills were in the range of 10(3)-10(4) cfu/m3, at the woodchipping mill, 10(3)-10(5) cfu/m3, and at joineries, 10(2)-10(4) cfu/m3. Although mean endotoxin levels were lower than the suggested threshold value of 20 ng/m3, some personal exposures at sawmills and a joinery exceeded the standard. The geometric mean personal (1-->3)-beta-D-glucan exposure level at the woodchipping mill was 2.32 ng/m3, at sawmills, 1.37 ng/m3, at logging sites, 2.02 ng/m3, and at joineries, 0.43 ng/m3. Highly significant associations were found between mean personal inhalable endotoxin exposures and Gram-negative bacteria levels (p < 0.0001), and mean personal inhalable (1-->3)-beta-D-glucan exposures and fungi levels (p = 0.0003). The prevalence of cough, phlegm, chronic bronchitis, nasal symptoms, frequent headaches, and eye and throat irritations was significantly higher among woodworkers than controls. Dose-response relationships were found between personal exposures and work-related symptoms among joinery workers and sawmill and chip mill workers.

  7. Effectiveness of a personalized ventilation system in reducing personal exposure against directly released simulated cough droplets.

    PubMed

    Pantelic, J; Tham, K W; Licina, D

    2015-12-01

    The inhalation intake fraction was used as an indicator to compare effects of desktop personalized ventilation and mixing ventilation on personal exposure to directly released simulated cough droplets. A cough machine was used to simulate cough release from the front, back, and side of a thermal manikin at distances between 1 and 4 m. Cough droplet concentration was measured with an aerosol spectrometer in the breathing zone of a thermal manikin. Particle image velocimetry was used to characterize the velocity field in the breathing zone. Desktop personalized ventilation substantially reduced the inhalation intake fraction compared to mixing ventilation for all investigated distances and orientations of the cough release. The results point out that the orientation between the cough source and the breathing zone of the exposed occupant is an important factor that substantially influences exposure. Exposure to cough droplets was reduced with increasing distance between cough source and exposed occupant. The results from this study show that an advanced air distribution system such as personalized ventilation reduces exposure to cough-released droplets better than commonly applied overhead mixing ventilation. This work can inform HVAC engineers about different aspects of air distribution systems’ performance and can serve as an aid in making critical design decisions. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Drying kinetics and characteristics of combined infrared-vacuum drying of button mushroom slices

    NASA Astrophysics Data System (ADS)

    Salehi, Fakhreddin; Kashaninejad, Mahdi; Jafarianlari, Ali

    2017-05-01

    Infrared-vacuum drying characteristics of button mushroom ( Agaricus bisporus) were evaluated in a combined dryer system. The effects of drying parameters, including infrared radiation power (150-375 W), system pressure (5-15 kPa) and time (0-160 min) on the drying kinetics and characteristics of button mushroom slices were investigated. Both the infrared lamp power and vacuum pressure influenced the drying time of button mushroom slices. The rate constants of the nine different kinetic's models for thin layer drying were established by nonlinear regression analysis of the experimental data which were found to be affected mainly by the infrared power level while system pressure had a little effect on the moisture ratios. The regression results showed that the Page model satisfactorily described the drying behavior of button mushroom slices with highest R value and lowest SE values. The effective moisture diffusivity increases as power increases and range between 0.83 and 2.33 × 10-9 m2/s. The rise in infrared power has a negative effect on the ΔE and with increasing in infrared radiation power it was increased.

  9. Poisoning: First Aid

    MedlinePlus

    ... Plants Foreign bodies such as watch or button batteries How you treat someone who may have been ... have applied medicated patches or swallowed a button battery. Call 911 or your local emergency number immediately ...

  10. Vascular ring complicates accidental button battery ingestion.

    PubMed

    Mercer, Ronald W; Schwartz, Matthew C; Stephany, Joshua; Donnelly, Lane F; Franciosi, James P; Epelman, Monica

    2015-01-01

    Button battery ingestion can lead to dangerous complications, including vasculoesophageal fistula formation. The presence of a vascular ring may complicate battery ingestion if the battery lodges at the level of the ring and its important vascular structures. We report a 4-year-old boy with trisomy 21 who was diagnosed with a vascular ring at the time of button battery ingestion and died 9 days after presentation due to massive upper gastrointestinal bleeding from esophageal erosion and vasculoesophageal fistula formation. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Graphical User Interface for a Remote Medical Monitoring System: U.S. Army Medic Recommendations

    DTIC Science & Technology

    2009-11-01

    screens. The majority of medics (70%) also wanted a name lis! screen that, when tapped , would go to an individual patient screen. In the name list...button has been pushed. Tapping on thaI button would prompt the user to enter the password. Tapping on the light button would illuminate the screen...a summary of current local weather conditions would be dis- played in the lower ! eft of the screen. In the lower right of this map screen is

  12. Inhalation a significant exposure route for chlorinated organophosphate flame retardants.

    PubMed

    Schreder, Erika D; Uding, Nancy; La Guardia, Mark J

    2016-05-01

    Chlorinated organophosphate flame retardants (ClOPFRs) are widely used as additive flame retardants in consumer products including furniture, children's products, building materials, and textiles. Tests of indoor media in homes, offices, and other environments have shown these compounds are released from products and have become ubiquitous indoor pollutants. In house dust samples from Washington State, U.S.A., ClOPFRs were the flame retardants detected in the highest concentrations. Two ClOPFRs, tris(1,3-dichloro-2-propyl)phosphate (TDCPP or TDCIPP) and tris(2-chloroethyl)phosphate (TCEP), have been designated as carcinogens, and there is growing concern about the toxicity of the homologue tris(1-chloro-2-propyl)phosphate (TCPP or TCIPP). In response to concerns about exposure to these compounds, the European Union and a number of U.S. states have taken regulatory action to restrict their use in certain product categories. To better characterize exposure to ClOPFRs, inhalation exposure was assessed using active personal air samplers in Washington State with both respirable and inhalable particulate fractions collected to assess the likelihood particles penetrate deep into the lungs. Concentrations of ∑ClOPFRs (respirable and inhalable) ranged from 97.1 to 1190 ng m(-3) (mean 426 ng m(-3)), with TCPP detected at the highest concentrations. In general, higher levels were detected in the inhalable particulate fraction. Total intake of ClOPFRs via the inhalation exposure route was estimated to exceed intake via dust ingestion, indicating that inhalation is an important route that should be taken into consideration in assessments of these compounds. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Exposure to inhalable dust, wheat flour and alpha-amylase allergens in industrial and traditional bakeries.

    PubMed

    Bulat, Petar; Myny, Katrien; Braeckman, Lutgart; van Sprundel, Marc; Kusters, Edouard; Doekes, Gert; Pössel, Kerstin; Droste, Jos; Vanhoorne, Michel

    2004-01-01

    This study was designed to characterize exposure to inhalable dust, wheat flour and alpha-amylase allergens in industrial and traditional bakeries. The study included 70 bakeries from the northern part of Belgium. Based on the degree of automation and a clear division of individual job tasks, four bakeries were identified as industrial and the remaining 66 were identified as traditional ones. Personal, as well as stationary, samples of inhalable dust were collected during full shift periods, usually 5-7 h. The portable pumps aspirated 2 l/min through Teflon personal dust samplers (Millipore, pore size 1.0 microm) mounted in PAS-6 sampling heads. In the collected samples the inhalable dust, wheat flour and alpha-amylase allergens were determined. Wheat flour allergens were measured using enzyme-linked immunosorbent assay inhibition and an antiwheat IgG4 serum pool. The alpha-amylase allergens were measured using a sandwich enzyme immunoassay with affinity-purified polyclonal rabbit IgG antibodies. In total, 440 samples (300 personal and 140 stationary) were processed. The highest inhalable dust exposure was observed in traditional bakeries among bread [geometric mean (GM) 2.10 mg/m3] and bread and pastry workers (GM 1.80 mg/m3). In industrial bakeries the highest dust exposure was measured in bread-producing workers (GM 1.06 mg/m3). Similar relations were observed for wheat flour and alpha-amylase allergens. Bread baking workers in traditional bakeries had the highest exposure to both allergens (wheat flour GM 22.33 microg/m(3), alpha-amylase GM 0.61 ng/m3). The exposure to wheat flour and alpha-amylase allergens in industrial bakeries was higher in bread baking workers (wheat flour GM 6.15 microg/m3, alpha-amylase GM 0.47 ng/m3) than in bread packing workers (wheat flour GM 2.79 microg/m3, alpha-amylase GM 0.15 ng/m3). The data presented suggest that, on average, exposure in the Belgium bakeries studied-industrial as well as traditional-is lower than or similar to bakeries in The Netherlands, Canada, Sweden, the United Kingdom and Finland. Furthermore, the exposure levels in traditional bakeries seem to be higher than in industrial bakeries.

  14. Dermal, inhalation, and internal exposure to 1,6-HDI and its oligomers in car body repair shop workers and industrial spray painters.

    PubMed

    Pronk, A; Yu, F; Vlaanderen, J; Tielemans, E; Preller, L; Bobeldijk, I; Deddens, J A; Latza, U; Baur, X; Heederik, D

    2006-09-01

    To study inhalation and dermal exposure to hexamethylene diisocyanate (HDI) and its oligomers as well as personal protection equipment (PPE) use during task performance in conjunction with urinary hexamethylene diamine (HDA) in car body repair shop workers and industrial spray painters. Personal task based inhalation samples (n = 95) were collected from six car body repair shops and five industrial painting companies using impingers with di-n-butylamine (DBA) in toluene. In parallel, dermal exposure was assessed using nitril rubber gloves. Gloves were submerged into DBA in toluene after sampling. Analysis for HDI and its oligomers was performed by LC-MS/MS. Urine samples were collected from 55 workers (n = 291) and analysed for HDA by GC-MS. Inhalation exposure was strongly associated with tasks during which aerosolisation occurs. Dermal exposure occurred during tasks that involve direct handling of paint. In car body repair shops associations were found between detectable dermal exposure and glove use (odds ratio (OR) 0.22, 95% confidence interval (CI) 0.09 to 0.57) and inhalation exposure level (OR 1.34, 95% CI 0.97 to 1.84 for a 10-fold increase). HDA in urine could be demonstrated in 36% and 10% of car body repair shop workers and industrial painting company workers respectively. In car body repair shops, the frequency of detectable HDA was significantly elevated at the end of the working day (OR 2.13, 95% CI 1.07 to 4.22 for 3-6 pm v 0-8 am). In both branches HDA was detected in urine of approximately 25% of the spray painters. In addition HDA was detected in urine of a large proportion of non-spray painters in car body repair shops. Although (spray) painting with lacquers containing isocyanate hardeners results in the highest external exposures to HDI and oligomers, workers that do not perform paint related tasks may also receive a considerable internal dose.

  15. Direct-reading inhalable dust monitoring--an assessment of current measurement methods.

    PubMed

    Thorpe, Andrew; Walsh, Peter T

    2013-08-01

    Direct-reading dust monitors designed specifically to measure the inhalable fraction of airborne dust are not widely available. Current practice therefore often involves comparing the response of photometer-type dust monitors with the concentration measured with a reference gravimetric inhalable sampler, which is used to adjust the dust monitor measurement. However, changes in airborne particle size can result in significant errors in the estimation of inhalable concentration by this method. The main aim of this study was to assess how these dust monitors behave when challenged with airborne dust containing particles in the inhalable size range and also to investigate alternative dust monitors whose response might not be as prone to variations in particle size or that could be adapted to measure inhalable dust concentration. Several photometer-type dust monitors and a Respicon TM, tapered element oscillating microbalance (TEOM) personal dust monitor (PDM) 3600, TEOM 1400, and Dustrak DRX were assessed for the measurement of airborne inhalable dust during laboratory and field trials. The PDM was modified to allow it to sample and measure larger particles in the inhalable size range. During the laboratory tests, the dust monitors and reference gravimetric samplers were challenged inside a large dust tunnel with aerosols of industrial dusts known to present an inhalable hazard and aluminium oxide powders with a range of discrete particle sizes. A constant concentration of each dust type was generated and peak concentrations of larger particles were periodically introduced to investigate the effects of sudden changes in particle size on monitor calibration. The PDM, Respicon, and DataRam photometer were also assessed during field trials at a bakery, joinery, and a grain mill. Laboratory results showed that the Respicon, modified PDM, and TEOM 1400 observed good linearity for all types of dust when compared with measurements made with a reference IOM sampler; the photometer-type dust monitors on the other hand showed little correlation. The Respicon also accurately measured the inhalable concentration, whereas the modified PDM underestimated it by ~27%. Photometer responses varied considerably with changing particle size, which resulted in appreciable errors in airborne inhalable dust concentration measurements. Similar trends were also observed during field trials. Despite having limitations, both the modified PDM and Respicon showed promise as real-time inhalable dust monitors.

  16. High current capacity electrical connector

    DOEpatents

    Bettis, Edward S.; Watts, Harry L.

    1976-01-13

    An electrical connector is provided for coupling high current capacity electrical conductors such as copper busses or the like. The connector is arranged in a "sandwiched" configuration in which a conductor plate contacts the busses along major surfaces thereof clamped between two stainless steel backing plates. The conductor plate is provided with a plurality of contact buttons affixed therein in a spaced array such that the caps of the buttons extend above the conductor plate surface to contact the busses. When clamping bolts provided through openings in the sandwiched arrangement are tightened, Belleville springs provided under the rim of each button cap are compressed and resiliently force the caps into contact with the busses' contacting surfaces to maintain a predetermined electrical contact area provided by the button cap tops. The contact area does not change with changing thermal or mechanical stresses applied to the coupled conductors.

  17. Button fixation technique for Achilles tendon reinsertion: a biomechanical study.

    PubMed

    Awogni, David; Chauvette, Guillaume; Lemieux, Marie-Line; Balg, Frédéric; Langelier, Ève; Allard, Jean-Pascal

    2014-01-01

    Chronic insertional tendinopathy of the Achilles tendon is a frequent and disabling pathologic entity. Operative treatment is indicated for patients for whom nonoperative management has failed. The treatment can consist of the complete detachment of the tendon insertion and extensive debridement. We biomechanically tested a new operative technique that uses buttons for fixation of the Achilles tendon insertion on the posterior calcaneal tuberosity and compared it with 2 standard bone anchor techniques. A total of 40 fresh-frozen cadaver specimens were used to compare 3 fixation techniques for reinserting the Achilles tendon: single row anchors, double row anchors, and buttons. The ultimate loads and failure mechanisms were recorded. The button assembly (median load 764 N, range 713 to 888) yielded a median fixation strength equal to 202% (range 137% to 251%) of that obtained with the double row anchors (median load 412 N, range 301 to 571) and 255% (range 213% to 317%) of that obtained with the single row anchors (median load 338 N, range 241 to 433N). The most common failure mechanisms were suture breakage with the buttons (55%) and pull out of the implant with the double row (70%) and single row (85%) anchors. The results of the present biomechanical cadaver study have shown that Achilles tendon reinsertion fixation using the button technique provides superior pull out strength than the bone anchors tested. Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  18. An EOG-Based Human-Machine Interface for Wheelchair Control.

    PubMed

    Huang, Qiyun; He, Shenghong; Wang, Qihong; Gu, Zhenghui; Peng, Nengneng; Li, Kai; Zhang, Yuandong; Shao, Ming; Li, Yuanqing

    2017-07-27

    Non-manual human-machine interfaces (HMIs) have been studied for wheelchair control with the aim of helping severely paralyzed individuals regain some mobility. The challenge is to rapidly, accurately and sufficiently produce control commands, such as left and right turns, forward and backward motions, acceleration, deceleration, and stopping. In this paper, a novel electrooculogram (EOG)-based HMI is proposed for wheelchair control. Thirteen flashing buttons are presented in the graphical user interface (GUI), and each of the buttons corresponds to a command. These buttons flash on a one-by-one manner in a pre-defined sequence. The user can select a button by blinking in sync with its flashes. The algorithm detects the eye blinks from a channel of vertical EOG data and determines the user's target button based on the synchronization between the detected blinks and the button's flashes. For healthy subjects/patients with spinal cord injuries (SCIs), the proposed HMI achieved an average accuracy of 96.7%/91.7% and a response time of 3.53 s/3.67 s with 0 false positive rates (FPRs). Using only one channel of vertical EOG signals associated with eye blinks, the proposed HMI can accurately provide sufficient commands with a satisfactory response time. The proposed HMI provides a novel non-manual approach for severely paralyzed individuals to control a wheelchair. Compared with a newly established EOG-based HMI, the proposed HMI can generate more commands with higher accuracy, lower FPR and fewer electrodes.

  19. Resuspension studies in the Marshall Islands.

    PubMed

    Shinn, J H; Homan, D N; Robison, W L

    1997-07-01

    The contribution of inhalation exposure to the total dose for residents of the Marshall Islands was monitored at occasions of opportunity on several islands in the Bikini and Enewetak Atolls. To determine the long-term potential for inhalation exposure, and to understand the mechanisms of redistribution and personal exposure, additional investigations were undertaken on Bikini Island under modified and controlled conditions. Experiments were conducted to provide key parameters for the assessment of inhalation exposure from plutonium-contaminated dust aerosols: characterization of the contribution of plutonium in soil-borne aerosols as compared to sea spray and organic aerosols, determination of plutonium resuspension rates as measured by the meteorological flux-gradient method during extreme conditions of a bare-soil vs. a stabilized surface, determination of the approximate individual exposures to resuspended plutonium by traffic, and studies of exposures to individuals in different occupational environments simulated by personal air sampling of workers assigned to a variety of tasks. Enhancement factors (defined as ratios of the plutonium-activity of suspended aerosols relative to the plutonium-activity of the soil) were determined to be less than 1 (typically 0.4 to 0.7) in the undisturbed, vegetated areas, but greater than 1 (as high as 3) for the case studies of disturbed bare soil, roadside travel, and for occupational duties in fields and in and around houses.

  20. Household concentrations and personal exposure of PM2.5 among urban residents using different cooking fuels.

    PubMed

    Li, Tianxin; Cao, Suzhen; Fan, Delong; Zhang, Yaqun; Wang, Beibei; Zhao, Xiuge; Leaderer, Brian P; Shen, Guofeng; Zhang, Yawei; Duan, Xiaoli

    2016-04-01

    Exposure to PM2.5 is a leading environmental risk factor for many diseases and premature deaths, arousing growing public concerns. In this study, indoor and outdoor PM2.5 concentrations were investigated during the heating and non-heating seasons in an urban area in northwest China. Personal inhalation exposure levels among different age groups were evaluated, and the difference attributable to different cooking fuels including coal, gas and electricity, was discussed. The average concentrations of PM2.5 in the kitchen and the bedroom were 125±51 and 119±64μg/m(3) during the heating season, and 80±67 and 80±50μg/m(3) during the non-heating season, respectively. Indoor PM2.5, from indoor combustion sources but also outdoor penetration, contributed to about 75% of the total PM2.5 exposure. Much higher indoor concentrations and inhalation exposure levels were found in households using coal for cooking compared to those using gas and electricity. Changing from coal to gas or electricity for cooking could result in a reduction of PM2.5 in the kitchen by 40-70% and consequently lower inhalation exposure levels, especially for children and women. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. The efficacies of pure LICAM(C) and DTPA on the retention of plutonium-238 and americium-241 in rats after their inhalation as nitrate and intravenous injection as citrate.

    PubMed

    Stradling, G N; Stather, J W; Gray, S A; Moody, J C; Ellender, M; Hodgson, A; Volf, V; Taylor, D M; Wirth, P; Gaskin, P W

    1989-10-01

    The pure carboxylated catechoyl amide LICAM(C) and the calcium and zinc salts of diethylenetriaminepenta-acetic acid (DTPA), were tested for efficacy for removing 238Pu and 241Am from rats after inhalation of the nitrate or intravenous injection of the citrate. The results were compared with the efficacy of methylated LICAM(C) used in previous experiments. It was shown that: (1) after inhalation of 238Pu nitrate, DTPA was far superior to pure LICAM(C); (2) after intravenous injection of 238Pu citrate, the infusion of DTPA plus LICAM(C) was only marginally more effective than DTPA alone; and (3) after inhalation or intravenous injection of 238Pu plus 241Am, the efficacy of pure LICAM(C) was only marginally more effective than the methylated form and neither form was effective for the decorporation of 241Am. It was concluded that DTPA, at present, remains the chelating agent of choice for treating persons accidentally contaminated with transportable forms of Pu and Am.

  2. Novel method to avoid the open-sky condition in penetrating keratoplasty: covered cornea technique.

    PubMed

    Arslan, Osman S; Unal, Mustafa; Arici, Ceyhun; Cicik, Erdoğan; Mangan, Serhat; Atalay, Eray

    2014-09-01

    The aim of this study was to present a novel technique to avoid the open-sky condition in pediatric and adult penetrating keratoplasty (PK). Seventy-two eyes of 65 infants and children and 44 eyes of 44 adult patients were operated on using this technique. After trephining the recipient cornea up to a depth of 50% to 70%, the anterior chamber was entered at 1 point. Then, only a 2 clock hour segment of the recipient button was incised, and this segment was sutured to the recipient rim with a single tight suture. The procedure was repeated until the entire recipient button was excised and resutured. The donor corneal button was sutured to the recipient corneal rim. The sutures between the recipient button and the rim were then cut off, and the recipient button was drawn out. None of the patients operated on with this technique developed complications related to the open-sky condition. Visual acuities, graft failure rates, and endothelial cell loss were comparable with the findings of studies performed for conventional PK. The technique described avoids the open-sky condition during the entire PK procedure. Endothelial cell loss rates are acceptable.

  3. Surgical treatment of pectoralis major muscle rupture with adjustable cortical button.

    PubMed

    Pochini, Alberto de Castro; Rodrigues, Marcus de Souza Barbosa; Yamashita, Larissa; Belangero, Paulo Santoro; Andreoli, Carlos Vicente; Ejnisman, Benno

    2018-01-01

    To assess the tendon reconstruction technique for total rupture of the pectoralis major muscle using an adjustable cortical button. Prospective study of 27 male patients with a mean age of 29.9 (SD = 5.3 years) and follow-up of 2.3 years. The procedure consisted of autologous grafts taken from the semitendinosus and gracilis tendons and an adjustable cortical button. Patients were evaluated functionally by the Bak criteria. The surgical treatment of pectoralis major muscle tendon reconstruction was performed in the early stages (three weeks) in six patients (22.2%) and in 21 patients (77.8%), in the late stages. Patients operated with the adjustable cortical button technique obtained 96.3% excellent or good results, with only 3.7% having poor results (Bak criteria). Of the total, 85.2% were injured while performing bench press exercises and 14.8%, during the practice of Brazilian jiu-jitsu or wrestling. All weight-lifting athletes had history of anabolic steroid use. The early or delayed reconstruction of ruptured pectoralis major muscle tendons with considerable muscle retraction, using an adjustable cortical button and autologous knee flexor grafts, showed a high rate of good results.

  4. [Autoshaping of a button-push response and eye movement in human subjects].

    PubMed

    Kimura, H; Fukui, I; Inaki, K

    1990-12-01

    Two experiments were conducted with human subjects to investigate the similarities and differences between animal and human behaviors under autoshaping procedures. In these experiments, light served as CS, and display on TV served as US. Whether the pushing button response or gazing response to CS could be obtained in human subjects under Pavlovian conditioning procedure was examined. In Experiment 1, uninstructed naive subjects were placed in a room containing a push-button and a TV display. Within the experimental sessions, the push-button was lit for 8 s as CS, and then paired with the display of a soft pornographic program on TV for 10 s. The result indicated that the modeling of pushing button promoted the increase of response probability among the subjects. The trials conducted after the rest period indicated an increase of response probability. In Experiment 2, a 4 cm square translucent panel was lit for 20 s as CS, and then paired with the display of a computer graphic picture on TV for 8 s as US. Some subjects started gazing at the CS for several seconds. These results indicated that some subjects could acquire the gazing response under the autoshaping procedure.

  5. Inhalability for aerosols at ultra-low windspeeds

    NASA Astrophysics Data System (ADS)

    Sleeth, Darrah K.; Vincent, James H.

    2009-02-01

    Most previous experimental studies of aerosol inhalability were conducted in wind tunnels for windspeeds greater than 0.5 ms-1. While that body of work was used to establish a convention for the inhalable fraction, results from studies in calm air chambers (for essentially zero windspeed) are being discussed as the basis of a modified criterion. However, information is lacking for windspeeds in the intermediate range, which - it so happens - pertain to most actual workplaces. With this in mind, we have developed a new experimental system to assess inhalability - and, ultimately, personal sampler performance - for aerosols with particle aerodynamic diameter within the range from about 9 to 90 μm for ultra-low windspeed environments from about 0.1 to 0.5 ms1. This new system contains an aerosol test facility, fully described elsewhere, that combines the physical attributes and performance characteristics of moving air wind tunnels and calm air chambers, both of which have featured individually in previous research. It also contains a specially-designed breathing, heated, life-sized mannequin that allows for accurate recovery of test particulate material that has been inhaled. Procedures have been developed that employ test aerosols of well-defined particle size distribution generated mechanically from narrowly-graded powders of fused alumina. Using this new system, we have conducted an extensive set of new experiments to measure the inhalability of a human subject (as represented by the mannequin), aimed at filling the current knowledge gap for conditions that are more realistic than those embodied in most previous research. These data reveal that inhalability throughout the range of interest is significantly different based on windspeed, indicating a rise in aspiration efficiency as windspeed decreases. Breathing flowrate and mode of breathing (i.e. nose versus mouth breathing) did not show significant differences for the inhalability of aerosols. On the whole however, the data obtained here are within the range of inhalability data that exist from the large body of the previous experimental work performed at the higher windspeeds. These latest findings are an important contribution to the ongoing discussion in international standards-setting bodies about the possible adjustment of the quantitative definition of what constitutes the inhalable fraction.

  6. Assessment of increased sampling pump flow rates in a disposable, inhalable aerosol sampler

    PubMed Central

    Stewart, Justin; Sleeth, Darrah K.; Handy, Rod G.; Pahler, Leon F.; Anthony, T. Renee; Volckens, John

    2017-01-01

    A newly designed, low-cost, disposable inhalable aerosol sampler was developed to assess workers personal exposure to inhalable particles. This sampler was originally designed to operate at 10 L/min to increase sample mass and, therefore, improve analytical detection limits for filter-based methods. Computational fluid dynamics modeling revealed that sampler performance (relative to aerosol inhalability criteria) would not differ substantially at sampler flows of 2 and 10 L/min. With this in mind, the newly designed inhalable aerosol sampler was tested in a wind tunnel, simultaneously, at flows of 2 and 10 L/min flow. A mannequin was equipped with 6 sampler/pump assemblies (three pumps operated at 2 L/min and three pumps at 10 L/min) inside a wind tunnel, operated at 0.2 m/s, which has been shown to be a typical indoor workplace wind speed. In separate tests, four different particle sizes were injected to determine if the sampler’s performance with the new 10 L/min flow rate significantly differed to that at 2 L/min. A comparison between inhalable mass concentrations using a Wilcoxon signed rank test found no significant difference in the concentration of particles sampled at 10 and 2 L/min for all particle sizes tested. Our results suggest that this new aerosol sampler is a versatile tool that can improve exposure assessment capabilities for the practicing industrial hygienist by improving the limit of detection and allowing for shorting sampling times. PMID:27676440

  7. Assessment of increased sampling pump flow rates in a disposable, inhalable aerosol sampler.

    PubMed

    Stewart, Justin; Sleeth, Darrah K; Handy, Rod G; Pahler, Leon F; Anthony, T Renee; Volckens, John

    2017-03-01

    A newly designed, low-cost, disposable inhalable aerosol sampler was developed to assess workers personal exposure to inhalable particles. This sampler was originally designed to operate at 10 L/min to increase sample mass and, therefore, improve analytical detection limits for filter-based methods. Computational fluid dynamics modeling revealed that sampler performance (relative to aerosol inhalability criteria) would not differ substantially at sampler flows of 2 and 10 L/min. With this in mind, the newly designed inhalable aerosol sampler was tested in a wind tunnel, simultaneously, at flows of 2 and 10 L/min flow. A mannequin was equipped with 6 sampler/pump assemblies (three pumps operated at 2 L/min and three pumps at 10 L/min) inside a wind tunnel, operated at 0.2 m/s, which has been shown to be a typical indoor workplace wind speed. In separate tests, four different particle sizes were injected to determine if the sampler's performance with the new 10 L/min flow rate significantly differed to that at 2 L/min. A comparison between inhalable mass concentrations using a Wilcoxon signed rank test found no significant difference in the concentration of particles sampled at 10 and 2 L/min for all particle sizes tested. Our results suggest that this new aerosol sampler is a versatile tool that can improve exposure assessment capabilities for the practicing industrial hygienist by improving the limit of detection and allowing for shorting sampling times.

  8. Effectiveness of Inhaled Loxapine in Dual-Diagnosis Patients: A Case Series.

    PubMed

    Roncero, Carlos; Ros-Cucurull, Elena; Grau-López, Lara; Fadeuilhe, Christian; Casas, Miguel

    2016-01-01

    Episodes of psychotic agitation are frequent in patients with dual diagnosis, that is, in patients with concomitant psychiatric and substance use disorders. Rapid intervention is needed to treat the agitation at a mild stage to prevent the escalation to aggressive behavior. Inhaled loxapine has been demonstrated to rapidly improve symptoms of mild-to-moderate agitation in adults with psychiatric disorders (schizophrenia and bipolar disorder), but data on patients with dual diagnosis are scarce. This study is a retrospective review of data from a case series of patients with dual diagnosis, which were attended for symptoms of agitation while at the emergency room (n = 9), in the outpatient clinic (n = 4), or during hospitalization (n = 1) at 1 center in Spain. All patients received inhaled loxapine for treating the agitation episodes. Data from 14 patients with dual diagnosis were reviewed. All patients had 1 or more psychiatric disorders (schizophrenia, bipolar I disorder, drug-induced psychotic disorder, posttraumatic stress, borderline or antisocial personality disorder, depression, or anxiety) along with a variety of substance use disorders (alcohol, cocaine, cannabis, amphetamines, hypnotics and antianxiety drugs, caffeine, or street drugs). Overall, only 1 dose of inhaled loxapine (9.1 mg) was needed to calm each patient during an acute episode of agitation. Inhaled loxapine was rapid, effective, and well accepted in all dual-pathology patients presenting with acute agitation in the emergency setting. Inhaled loxapine facilitated both patient cooperation and an adequate management of his or her disease.

  9. Development of the Releasable Asbestos Field Sampler

    EPA Science Inventory

    A risk assessment for intermittent, low-level exposure to asbestos requires personal breathing concentration data. Currently, activity-based sampling (ABS) is the preferred approach to measurement of a person’s inhalation exposure; i.e., asbestos structures per cubic centimeter ...

  10. Vascular effects of ultrafine particles in persons with type 2 diabetes

    EPA Science Inventory

    BACKGROUND: Diabetes confers an increased risk for cardiovascular effects of airborne particles. OBJECTIVE: We hypothesized that inhalation of elemental carbon ultrafine particles (UFP) would activate blood platelets and vascular endothelium in people with type 2 diabetes. ...

  11. Soft robot design methodology for `push-button' manufacturing

    NASA Astrophysics Data System (ADS)

    Paik, Jamie

    2018-06-01

    `Push-button' or fully automated manufacturing would enable the production of robots with zero intervention from human hands. Realizing this utopia requires a fundamental shift from a sequential (design-materials-manufacturing) to a concurrent design methodology.

  12. MedlinePlus FAQ: Disease or Condition Information

    MedlinePlus

    ... on the Health Topics button on the MedlinePlus homepage. You can also find the Health Topics button ... MedlinePlus Connect for EHRs For Developers U.S. National Library of Medicine 8600 Rockville Pike, Bethesda, MD 20894 ...

  13. Development of non-keyboard input device checklists through assessments.

    PubMed

    Woods, Valerie; Hastings, Sarah; Buckle, Peter; Haslam, Roger

    2003-11-01

    An assessment of non-keyboard input devices (NKID) was conducted to identify factors for good design in relation to operation, performance and comfort. Twenty-seven NKID users, working in health and safety, evaluated eight devices that included mice, trackballs and a joystick mouse. The factors considered important for good design were: (1) comfortable hand and finger position, (2) adequate control, (3) intuitive and easy to use, (4) ease of device, button and trackball movement, (5) good interaction with software, (6) provision of suitable accessories. Mice were rated more favourably than trackballs or the joystick mouse. The design of the standard 2-button mouse (D4) was considered most desirable to use; the 3-button mouse (D1) and 3-button curved mouse (D8) were also favoured. Assessment data and comments were drawn together with previously published research to produce useful tools for NKID purchasing (i.e. Device Purchasing Checklist) and assessment (i.e. Device Assessment Checklist).

  14. Human Indoor Exposure to Airborne Halogenated Flame Retardants: Influence of Airborne Particle Size.

    PubMed

    La Guardia, Mark J; Schreder, Erika D; Uding, Nancy; Hale, Robert C

    2017-05-09

    Inhalation of halogenated flame-retardants (HFRs) released from consumer products is an important route of exposure. However, not all airborne HFRs are respirable, and thus interact with vascular membranes within the gas exchange (alveolar) region of the lung. HFRs associated with large (>4 µm), inhalable airborne particulates are trapped on the mucosal lining of the respiratory tract and then are expelled or swallowed. The latter may contribute to internal exposure via desorption from particles in the digestive tract. Exposures may also be underestimated if personal activities that re-suspend particles into the breathing zone are not taken into account. Here, samples were collected using personal air samplers, clipped to the participants' shirt collars (n = 18). We observed that the larger, inhalable air particulates carried the bulk (>92%) of HFRs. HFRs detected included those removed from commerce (i.e., polybrominated diphenyl ethers (Penta-BDEs: BDE-47, -85, -100, -99, and -153)), their replacements; e.g., 2-ethylhexyl 2,3,4,5-tetrabromobenzoate (TBB or EH-TBB); bis(2-ethylhexyl) 3,4,5,6-tetrabromophthalate (TBPH or BEH-TEBP) and long-produced chlorinated organophosphate-FRs (ClOPFRs): tris(2-chloroethyl)phosphate (TCEP), tris(1-chloro-2-propyl)phosphate (TCPP or TCIPP), and tris(1,3-dichloro-2-propyl)phosphate (TDCPP or TDCIPP). Our findings suggest estimates relying on a single exposure route, i.e., alveolar gas exchange, may not accurately estimate HFR internal dosage, as they ignore contributions from larger inhalable particulates that enter the digestive tract. Consideration of the fate and bioavailability of these larger particulates resulted in higher dosage estimates for HFRs with log K oa < 12 (i.e., Penta-BDEs and ClOPFRs) and lower estimates for those with log K oa > 12 (i.e., TBB and TBPH) compared to the alveolar route exposure alone. Of those HFRs examined, the most significant effect was the lower estimate by 41% for TBPH. The bulk of TBPH uptake from inhaled particles was estimated to be through the digestive tract, with lower bioavailability. We compared inhalation exposure estimates to chronic oral reference doses (R f Ds) established by several regulatory agencies. The U.S. Environmental Protection Agency (EPA) R f D levels for several HFRs are considered outdated; however, BDE-99 levels exceeded those suggested by the Dutch National Institute for Public Health and the Environment (RIVM) by up to 26 times. These findings indicate that contributions and bioavailability of respirable and inhalable airborne particulates should both be considered in future risk assessments.

  15. Human Indoor Exposure to Airborne Halogenated Flame Retardants: Influence of Airborne Particle Size

    PubMed Central

    La Guardia, Mark J.; Schreder, Erika D.; Uding, Nancy; Hale, Robert C.

    2017-01-01

    Inhalation of halogenated flame-retardants (HFRs) released from consumer products is an important route of exposure. However, not all airborne HFRs are respirable, and thus interact with vascular membranes within the gas exchange (alveolar) region of the lung. HFRs associated with large (>4 µm), inhalable airborne particulates are trapped on the mucosal lining of the respiratory tract and then are expelled or swallowed. The latter may contribute to internal exposure via desorption from particles in the digestive tract. Exposures may also be underestimated if personal activities that re-suspend particles into the breathing zone are not taken into account. Here, samples were collected using personal air samplers, clipped to the participants’ shirt collars (n = 18). We observed that the larger, inhalable air particulates carried the bulk (>92%) of HFRs. HFRs detected included those removed from commerce (i.e., polybrominated diphenyl ethers (Penta-BDEs: BDE-47, -85, -100, -99, and -153)), their replacements; e.g., 2-ethylhexyl 2,3,4,5-tetrabromobenzoate (TBB or EH-TBB); bis(2-ethylhexyl) 3,4,5,6-tetrabromophthalate (TBPH or BEH-TEBP) and long-produced chlorinated organophosphate-FRs (ClOPFRs): tris(2-chloroethyl)phosphate (TCEP), tris(1-chloro-2-propyl)phosphate (TCPP or TCIPP), and tris(1,3-dichloro-2-propyl)phosphate (TDCPP or TDCIPP). Our findings suggest estimates relying on a single exposure route, i.e., alveolar gas exchange, may not accurately estimate HFR internal dosage, as they ignore contributions from larger inhalable particulates that enter the digestive tract. Consideration of the fate and bioavailability of these larger particulates resulted in higher dosage estimates for HFRs with log Koa < 12 (i.e., Penta-BDEs and ClOPFRs) and lower estimates for those with log Koa > 12 (i.e., TBB and TBPH) compared to the alveolar route exposure alone. Of those HFRs examined, the most significant effect was the lower estimate by 41% for TBPH. The bulk of TBPH uptake from inhaled particles was estimated to be through the digestive tract, with lower bioavailability. We compared inhalation exposure estimates to chronic oral reference doses (RfDs) established by several regulatory agencies. The U.S. Environmental Protection Agency (EPA) RfD levels for several HFRs are considered outdated; however, BDE-99 levels exceeded those suggested by the Dutch National Institute for Public Health and the Environment (RIVM) by up to 26 times. These findings indicate that contributions and bioavailability of respirable and inhalable airborne particulates should both be considered in future risk assessments. PMID:28486433

  16. Modified Labial Button Technique for Maintaining Occlusion After Caudal Mandibular Fracture/Temporomandibular Joint Luxation in the Cat.

    PubMed

    Goodman, Alice E; Carmichael, Daniel T

    2016-03-01

    Maxillofacial trauma in cats often results in mandibular symphyseal separation in addition to injuries of the caudal mandible and/or temporomandibular joint (TMJ). Caudal mandibular and TMJ injuries are difficult to access and stabilize using direct fixation techniques, thus indirect fixation is commonly employed. The immediate goals of fixation include stabilization for return to normal occlusion and function with the long-term objective of bony union. Indirect fixation techniques commonly used for stabilization of caudal mandibular and temporomandibular joint fracture/luxation include maxillomandibular fixation (MMF) with acrylic composite, interarcade wiring, tape muzzles, and the bignathic encircling and retaining device (BEARD) technique. This article introduces a modification of the previously described "labial reverse suture through buttons" technique used by Koestlin et al and the "labial locking with buttons" technique by Rocha et al. In cases with minimally displaced subcondylar and pericondylar fractures without joint involvement, the labial button technique can provide sufficient stabilization for healing. Advantages of the modified labial button technique include ease of application, noninvasive nature, and use of readily available materials. The construct can remain in place for a variable of amount of time, depending on its intended purpose. It serves as an alternative to the tape muzzle, which is rarely tolerated by cats. This technique can be easily used in conjunction with other maxillomandibular repairs, such as cerclage wire fixation of mandibular symphyseal separation. The purpose of this article is to demonstrate a modified labial button technique for maintaining occlusion of feline caudal mandibular fractures/TMJ luxations in a step-by-step fashion.

  17. Effects of contamination by either blood or a hemostatic agent on the shear bond strength of orthodontic buttons

    PubMed Central

    Alkis, Huseyin; Turkkahraman, Hakan

    2013-01-01

    Objective To evaluate the effects of contamination by either blood or a hemostatic agent on the shear bond strength (SBS) of orthodontic buttons. Methods We used 45 freshly extracted, non-carious, impacted third molars that were divided into 3 groups of 15. Each tooth was etched with 37% phosphoric acid gel for 30 s. Human blood or the blood stopper agent was applied to the tooth surface in groups I and II, respectively. Group III teeth were untreated (controls). Orthodontic buttons were bonded to the teeth using light-curing composite resin. After bonding, the SBS of the button was determined using a Universal testing machine. Any adhesive remaining after debonding was assessed and scored according to the modified adhesive remnant index (ARI). ANOVA with post-hoc Tukey's test was used to determine significant differences in SBS and Fisher's exact test, to determine significant differences in ARI scores among groups. Results ANOVA indicated a significant difference between groups (p < 0.001). The highest SBS values were measured in group III (10.73 ± 0.96 MPa). The SBS values for teeth in groups I and II were significantly lower than that of group III (p < 0.001). The lowest SBS values were observed in group I teeth (4.17 ± 1.11 MPa) (p < 0.001). Conclusions Contamination of tooth surfaces with either blood or hemostatic agent significantly decreased the SBS of orthodontic buttons. When the contamination risk is high, it is recommended to use the blood stopper agent when bonding orthodontic buttons on impacted teeth. PMID:23671834

  18. Smoke alarm tests may not adequately indicate smoke alarm function.

    PubMed

    Peek-Asa, Corinne; Yang, Jingzhen; Hamann, Cara; Young, Tracy

    2011-01-01

    Smoke alarms are one of the most promoted prevention strategies to reduce residential fire deaths, and they can reduce residential fire deaths by half. Smoke alarm function can be measured by two tests: the smoke alarm button test and the chemical smoke test. Using results from a randomized trial of smoke alarms, we compared smoke alarm response to the button test and the smoke test. The smoke alarms found in the study homes at baseline were tested, as well as study alarms placed into homes as part of the randomized trial. Study alarms were tested at 12 and 42 months postinstallation. The proportion of alarms that passed the button test but not the smoke test ranged from 0.5 to 5.8% of alarms; this result was found most frequently among ionization alarms with zinc or alkaline batteries. These alarms would indicate to the owner (through the button test) that the smoke alarm was working, but the alarm would not actually respond in the case of a fire (as demonstrated by failing the smoke test). The proportion of alarms that passed the smoke test but not the button test ranged from 1.0 to 3.0%. These alarms would appear nonfunctional to the owner (because the button test failed), even though the alarm would operate in response to a fire (as demonstrated by passing the smoke test). The general public is not aware of the potential for inaccuracy in smoke alarm tests, and burn professionals can advocate for enhanced testing methods. The optimal test to determine smoke alarm function is the chemical smoke test.

  19. The validity, reliability, and utility of the iButton® for measurement of body temperature circadian rhythms in sleep/wake research.

    PubMed

    Hasselberg, Michael J; McMahon, James; Parker, Kathy

    2013-01-01

    Changes in core body temperature due to heat transfer through the skin have a major influence on sleep regulation. Traditional measures of skin temperature are often complicated by extensive wiring and are not practical for use in normal living conditions. This review describes studies examining the reliability, validity and utility of the iButton®, a wireless peripheral thermometry device, in sleep/wake research. A review was conducted of English language literature on the iButton as a measure of circadian body temperature rhythms associated with the sleep/wake cycle. Seven studies of the iButtton as a measure of human body temperature were included. The iButton was found to be a reliable and valid measure of body temperature. Its application to human skin was shown to be comfortable and tolerable with no significant adverse reactions. Distal skin temperatures were negatively correlated with sleep/wake activity, and the temperature gradient between the distal and proximal skin (DPG) was identified as an accurate physiological correlate of sleep propensity. Methodological issues included site of data logger placement, temperature masking factors, and temperature data analysis. The iButton is an inexpensive, wireless data logger that can be used to obtain a valid measurement of human skin temperature. It is a practical alternative to traditional measures of circadian rhythms in sleep/wake research. Further research is needed to determine the utility of the iButton in vulnerable populations, including those with neurodegenerative disorders and memory impairment and pediatric populations. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. Parallel particle impactor - novel size-selective particle sampler for accurate fractioning of inhalable particles

    NASA Astrophysics Data System (ADS)

    Trakumas, S.; Salter, E.

    2009-02-01

    Adverse health effects due to exposure to airborne particles are associated with particle deposition within the human respiratory tract. Particle size, shape, chemical composition, and the individual physiological characteristics of each person determine to what depth inhaled particles may penetrate and deposit within the respiratory tract. Various particle inertial classification devices are available to fractionate airborne particles according to their aerodynamic size to approximate particle penetration through the human respiratory tract. Cyclones are most often used to sample thoracic or respirable fractions of inhaled particles. Extensive studies of different cyclonic samplers have shown, however, that the sampling characteristics of cyclones do not follow the entire selected convention accurately. In the search for a more accurate way to assess worker exposure to different fractions of inhaled dust, a novel sampler comprising several inertial impactors arranged in parallel was designed and tested. The new design includes a number of separated impactors arranged in parallel. Prototypes of respirable and thoracic samplers each comprising four impactors arranged in parallel were manufactured and tested. Results indicated that the prototype samplers followed closely the penetration characteristics for which they were designed. The new samplers were found to perform similarly for liquid and solid test particles; penetration characteristics remained unchanged even after prolonged exposure to coal mine dust at high concentration. The new parallel impactor design can be applied to approximate any monotonically decreasing penetration curve at a selected flow rate. Personal-size samplers that operate at a few L/min as well as area samplers that operate at higher flow rates can be made based on the suggested design. Performance of such samplers can be predicted with high accuracy employing well-established impaction theory.

  1. Wood Dust Sampling: Field Evaluation of Personal Samplers When Large Particles Are Present

    PubMed Central

    Lee, Taekhee; Harper, Martin; Slaven, James E.; Lee, Kiyoung; Rando, Roy J.; Maples, Elizabeth H.

    2011-01-01

    Recent recommendations for wood dust sampling include sampling according to the inhalable convention of International Organization for Standardization (ISO) 7708 (1995) Air quality—particle size fraction definitions for health-related sampling. However, a specific sampling device is not mandated, and while several samplers have laboratory performance approaching theoretical for an ‘inhalable’ sampler, the best choice of sampler for wood dust is not clear. A side-by-side field study was considered the most practical test of samplers as laboratory performance tests consider overall performance based on a wider range of particle sizes than are commonly encountered in the wood products industry. Seven companies in the wood products industry of the Southeast USA (MS, KY, AL, and WV) participated in this study. The products included hardwood flooring, engineered hardwood flooring, door skins, shutter blinds, kitchen cabinets, plywood, and veneer. The samplers selected were 37-mm closed-face cassette with ACCU-CAP™, Button, CIP10-I, GSP, and Institute of Occupational Medicine. Approximately 30 of each possible pairwise combination of samplers were collected as personal sample sets. Paired samplers of the same type were used to calculate environmental variance that was then used to determine the number of pairs of samples necessary to detect any difference at a specified level of confidence. Total valid sample number was 888 (444 valid pairs). The mass concentration of wood dust ranged from 0.02 to 195 mg m−3. Geometric mean (geometric standard deviation) and arithmetic mean (standard deviation) of wood dust were 0.98 mg m−3 (3.06) and 2.12 mg m−3 (7.74), respectively. One percent of the samples exceeded 15 mg m−3, 6% exceeded 5 mg m−3, and 48% exceeded 1 mg m−3. The number of collected pairs is generally appropriate to detect a 35% difference when outliers (negative mass loadings) are removed. Statistical evaluation of the nonsimilar sampler pair results produced a finding of no significant difference between any pairing of sampler type. A practical consideration for sampling in the USA is that the ACCU-CAP™ is similar to the sampler currently used by the Occupational Safety and Health Administration for purposes of demonstrating compliance with its permissible exposure limit for wood dust, which is the same as for Particles Not Otherwise Regulated, also known as inert dust or nuisance dust (Method PV2121). PMID:21036895

  2. 78 FR 27995 - Notice of Inventory Completion for Native American Human Remains and Associated Funerary Objects...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-13

    ... fragments, 29 historic ceramic sherds, 1 prehistoric ceramic sherd, 128 unmodified faunal bone fragments, 1 modified deer rib, 3 bone buttons, 4 chipped stone flakes, 2 wooden buttons, 1 historic clay pipe bowl...

  3. Comparison of numeric keyboard and CRT line-labeled buttons for information access. [in computerized, area navigation system for aircraft

    NASA Technical Reports Server (NTRS)

    Williams, D.

    1976-01-01

    Test were conducted to determine whether differences in speed and accuracy are experienced when using either line-labeled index buttons or a numeric keyboard for page selection in airborne CRT-display area navigation systems. The experiment was conducted with six airline pilots, each flying the same two simulated RNAV routes. Three pilot subjects used line-labeled buttons adjacent to the CRT screen, while three used a numeric keyboard for page access. The hypothesis of no differences in response times between the two modes of access could not be rejected.

  4. Button battery ingestion: the Greek experience and review of the literature.

    PubMed

    Amanatidou, Virginia; Sofidiotou, Vassiliki; Fountas, Kostas; Kalostou, Angeliki; Tsamadou, Athina; Papathanassiou, Vassiliki; Neou, Polyxeni

    2011-03-01

    Foreign body ingestion is a common cause of admission in the pediatric emergency room. In the past, button batteries accounted for less than 2% of the foreign bodies ingested by small children, but in the last 2 decades, they show a rapidly increased frequency. The aim of the present study was to evaluate the potential risk after button battery ingestion in relation with the clinical manifestations and to perform a treatment-observation protocol in accordance with the international procedure. In a prospective observational analysis from November 2007 through February 2008, 31 cases of button battery ingestion were recorded by the Greek Poison Information Center. The interval between the accidental ingestion and first medical contact ranged from 5 minutes to 10 days. After initial evaluation including clinical examination and radiological localization of the foreign body, all cases were treated as outpatients. Reported complications included "black stools" in 9% and diarrhea in 3% of cases. In 1 case, the battery was endoscopically removed. The role of primary care physicians in informing the public about the potential danger of button battery digestion is crucial. Pediatricians should educate the parents about this hazard, as part of the routine guidelines for childproofing at home. Once again, prolepsis is the best policy.

  5. Diversity of Bacterial Communities on Four Frequently Used Surfaces in a Large Brazilian Teaching Hospital

    PubMed Central

    Pereira da Fonseca, Tairacan Augusto; Pessôa, Rodrigo; Felix, Alvina Clara; Sanabani, Sabri Saeed

    2016-01-01

    Frequently used hand-touch surfaces in hospital settings have been implicated as a vehicle of microbial transmission. In this study, we aimed to investigate the overall bacterial population on four frequently used surfaces using a culture-independent Illumina massively parallel sequencing approach of the 16S rRNA genes. Surface samples were collected from four sites, namely elevator buttons (EB), bank machine keyboard buttons (BMKB), restroom surfaces, and the employee biometric time clock system (EBTCS), in a large public and teaching hospital in São Paulo. Taxonomical composition revealed the abundance of Firmicutes phyla, followed by Actinobacteria and Proteobacteria, with a total of 926 bacterial families and 2832 bacterial genera. Moreover, our analysis revealed the presence of some potential pathogenic bacterial genera, including Salmonella enterica, Klebsiella pneumoniae, and Staphylococcus aureus. The presence of these pathogens in frequently used surfaces enhances the risk of exposure to any susceptible individuals. Some of the factors that may contribute to the richness of bacterial diversity on these surfaces are poor personal hygiene and ineffective routine schedules of cleaning, sanitizing, and disinfecting. Strict standards of infection control in hospitals and increased public education about hand hygiene are recommended to decrease the risk of transmission in hospitals among patients. PMID:26805866

  6. Exposure to Inhalable, Respirable, and Ultrafine Particles in Welding Fume

    PubMed Central

    Pesch, Beate

    2012-01-01

    This investigation aims to explore determinants of exposure to particle size-specific welding fume. Area sampling of ultrafine particles (UFP) was performed at 33 worksites in parallel with the collection of respirable particles. Personal sampling of respirable and inhalable particles was carried out in the breathing zone of 241 welders. Median mass concentrations were 2.48 mg m−3 for inhalable and 1.29 mg m−3 for respirable particles when excluding 26 users of powered air-purifying respirators (PAPRs). Mass concentrations were highest when flux-cored arc welding (FCAW) with gas was applied (median of inhalable particles: 11.6 mg m−3). Measurements of particles were frequently below the limit of detection (LOD), especially inside PAPRs or during tungsten inert gas welding (TIG). However, TIG generated a high number of small particles, including UFP. We imputed measurements

  7. Exposure to inhalable, respirable, and ultrafine particles in welding fume.

    PubMed

    Lehnert, Martin; Pesch, Beate; Lotz, Anne; Pelzer, Johannes; Kendzia, Benjamin; Gawrych, Katarzyna; Heinze, Evelyn; Van Gelder, Rainer; Punkenburg, Ewald; Weiss, Tobias; Mattenklott, Markus; Hahn, Jens-Uwe; Möhlmann, Carsten; Berges, Markus; Hartwig, Andrea; Brüning, Thomas

    2012-07-01

    This investigation aims to explore determinants of exposure to particle size-specific welding fume. Area sampling of ultrafine particles (UFP) was performed at 33 worksites in parallel with the collection of respirable particles. Personal sampling of respirable and inhalable particles was carried out in the breathing zone of 241 welders. Median mass concentrations were 2.48 mg m(-3) for inhalable and 1.29 mg m(-3) for respirable particles when excluding 26 users of powered air-purifying respirators (PAPRs). Mass concentrations were highest when flux-cored arc welding (FCAW) with gas was applied (median of inhalable particles: 11.6 mg m(-3)). Measurements of particles were frequently below the limit of detection (LOD), especially inside PAPRs or during tungsten inert gas welding (TIG). However, TIG generated a high number of small particles, including UFP. We imputed measurements

  8. Size distribution of salbutamol/ipratropium aerosols produced by different nebulizers in the absence and presence of heat and humidification.

    PubMed

    Yang, Ssu-Han; Yang, Tsung-Ming; Lin, Hui-Ling; Tsai, Ying-Huang; Fang, Tien-Pei; Wan, Gwo-Hwa

    2018-02-01

    Few studies have evaluated the size distribution of inhaled and exhaled aerosolized drugs, or the effect of heated humidification on particle size and lung deposition. The present study evaluated these aspects of bronchodilator (salbutamol/ipratropium) delivery using a lung model in the absence and presence of heat and humidification. We positioned filters to collect and measure the initial drug, inhaled drug, and exhaled drug. Particle size distribution was evaluated using an 8-stage Marple personal cascade impactor with 0.2-μm polycarbonate filters. A greater inhaled drug mass was delivered using a vibrating mesh nebulizer (VMN) than by using a small volume nebulizer (SVN), when heated humidifiers were not employed. When heated and humidified medical gas was used, there was no significant difference between the inhaled drug mass delivered by the VMN and that delivered by the SVN. A significantly greater mass of inhaled 1.55-μm drug particles was produced by the VMN than with the SVN, under heated and humidified conditions. However, the mass median aerodynamic diameters (MMADs) of the aerosolized drug produced by the SVN and VMN did not differ significantly under the same conditions. The VMN produced more fine particles of salbutamol/ipratropium, and the drug particle size clearly increased in the presence of heat and humidification. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Determining exhaust fumes exposure in chainsaw operations.

    PubMed

    Neri, F; Foderi, C; Laschi, A; Fabiano, F; Cambi, M; Sciarra, G; Aprea, M C; Cenni, A; Marchi, E

    2016-11-01

    The objective of this study was to investigate the inhalation exposure of forest operators to polycyclic aromatic hydrocarbons (PAHs) and BTEX (benzene, toluene, ethylbenzene and total xylenes) contained in the exhaust fumes released from chainsaws and to suggest possible countermeasures. The study was carried out in four silvicultural treatments (coppice clearcut, conifer thinning, conifer pruning, and sanitary cut), using three types of chainsaw fuel (normal two-stroke petrol mix and two alkylate fuels). Eighty personal air samples were collected; IOM samplers combined with Amberlite XAD-2 sorbent tubes were used for collecting PAHs and Radiello ® samplers were used for BTEX. Results indicate that none of the four silvicultural treatments significantly affected the PAHs and BTEX inhalation exposure of forest workers. On the other hand, statistically significant differences were recorded in the inhalation exposure to PAHs and BTEX when using different fuel types. In particular, the inhalation exposure to PAHs and BTEX was generally one order of magnitude lower when using modern alkylate fuels as compared to the traditional oil and lead-free petrol mixture. The small, non-statistically significant differences in inhalation exposure recorded between the two alkylate fuels suggests that the two fuels might be equivalent in terms of quality. Our study indicates that while forest workers are exposed to PAHs and BTEX, the maximum values are generally well below accepted occupational exposure limits. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. EOSINOPHIL INFLUX TO THE NASAL AIRWAY FOLLOWING LOCAL, LOW-LEVEL LPS CHALLENGE IN HUMANS

    EPA Science Inventory

    Background: Recent obervations show that atopic asthmatic subjects have increased sensitivity to respirable endotoxin (or LPS) compared with normal persons. In vitro studies demonstrate that LPS enchances eosinophil survival. These obervations suggest that the effects of inhal...

  11. REGIONAL DEPOSITION OF COARSE PARTICLES AND VENTILATION DISTRIBUTION IN PATIENTS WITH CYSTIC FIBROSIS

    EPA Science Inventory

    The efficacy of inhaled pharmaceuticals depends, in part, on their site of respiratory deposition. Markedly nonuniform ventilation distribution may occur in persons with obstructive airways diseases and may affect particle deposition. We studied the relationship between regional ...

  12. A Model to Predict the Breathing Zone Concentrations of Particles Emitted from Surfaces

    EPA Science Inventory

    Activity based sampling (ABS) is typically performed to assess inhalation exposure to particulate contaminants known to have low, heterogeneous concentrations on a surface. Activity based sampling determines the contaminant concentration in a person's breathing zone as they perfo...

  13. Disposable Electronic Cigarettes and Electronic Hookahs: Evaluation of Performance

    PubMed Central

    Williams, Monique; Ghai, Sanjay

    2015-01-01

    Introduction: The purpose of this study was to characterize the performance of disposable button-activated and disposable airflow-activated electronic cigarettes (EC) and electronic hookahs (EH). Methods: The airflow rate required to produce aerosol, pressure drop, and the aerosol absorbance at 420nm were measured during smoke-outs of 9 disposable products. Three units of each product were tested in these experiments. Results: The airflow rates required to produce aerosol and the aerosol absorbances were lower for button-activated models (3mL/s; 0.41–0.55 absorbance) than for airflow-activated models (7–17mL/s; 0.48–0.84 absorbance). Pressure drop was also lower across button-activated products (range = 6–12mm H2O) than airflow-activated products (range = 15–67mm H20). For 25 of 27 units tested, airflow did not have to be increased during smoke-out to maintain aerosol production, unlike earlier generation models. Two brands had uniform performance characteristics for all parameters, while 3 had at least 1 product that did not function normally. While button-activated models lasted 200 puffs or less and EH airflow-activated models often lasted 400 puffs, none of the models produced as many puffs as advertised. Puff number was limited by battery life, which was shorter in button-activated models. Conclusion: The performance of disposable products was differentiated mainly by the way the aerosol was produced (button vs airflow-activated) rather than by product type (EC vs EH). Users needed to take harder drags on airflow-activated models. Performance varied within models, and battery life limited the number of puffs. Data suggest quality control in manufacturing varies among brands. PMID:25104117

  14. Insertion of Balloon Retained Gastrostomy Buttons: A 5-Year Retrospective Review of 260 Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Power, Sarah, E-mail: sarahpower28@yahoo.co.uk; Kavanagh, Liam N.; Shields, Mary C.

    Radiologically inserted gastrostomy (RIG) is an established way of maintaining enteral nutrition in patients who cannot maintain nutrition orally. The purpose of this study was to evaluate the safety and efficacy of primary placement of a wide bore button gastrostomy in a large, varied patient population through retrospective review. All patients who underwent gastrostomy placement from January 1, 2004 to January 1, 2009 were identified. 18-Fr gastrostomy buttons (MIC-Key G) were inserted in the majority. Follow-up ranged from 6 months to 4.5 years. A total of 260 patients (M:F 140:120, average age 59.2 years) underwent gastrostomy during the study period.more » Overall success rate for RIG placement was 99.6 %, with success rate of 95.3 % for primary button insertion. Indications included neurological disorders (70 %), esophageal/head and neck malignancy (21 %), and other indications (9 %). Major and minor complication rates were 1.2 and 12.8 %, respectively. Thirty-day mortality rate was 6.8 %. One third of patients underwent gastrostomy reinsertion during the study period, the main indication for which was inadvertent catheter removal. Patency rate was high at 99.5 %. The maximum number of procedures in any patient was 8 (n = 2), and the average tube dwell time was 125 days. Primary radiological insertion of a wide bore button gastrostomy is a safe technique, with high success rate, high patency rate, and low major complication rate. We believe that it is feasible to attempt button gastrostomy placement in all patients, once tract length is within limits of tube length. If difficulty is encountered, then a standard tube may simply be placed instead.« less

  15. The joint Simon effect depends on perceived agency, but not intentionality, of the alternative action

    PubMed Central

    Stenzel, Anna; Dolk, Thomas; Colzato, Lorenza S.; Sellaro, Roberta; Hommel, Bernhard; Liepelt, Roman

    2014-01-01

    A co-actor's intentionality has been suggested to be a key modulating factor for joint action effects like the joint Simon effect (JSE). However, in previous studies intentionality has often been confounded with agency defined as perceiving the initiator of an action as being the causal source of the action. The aim of the present study was to disentangle the role of agency and intentionality as modulating factors of the JSE. In Experiment 1, participants performed a joint go/nogo Simon task next to a co-actor who either intentionally controlled a response button with own finger movements (agency+/intentionality+) or who passively placed the hand on a response button that moved up and down on its own as triggered by computer signals (agency−/intentionality−). In Experiment 2, we included a condition in which participants believed that the co-actor intentionally controlled the response button with a Brain-Computer Interface (BCI) while placing the response finger clearly besides the response button, so that the causal relationship between agent and action effect was perceptually disrupted (agency−/intentionality+). As a control condition, the response button was computer controlled while the co-actor placed the response finger besides the response button (agency−/intentionality−). Experiment 1 showed that the JSE is present with an intentional co-actor and causality between co-actor and action effect, but absent with an unintentional co-actor and a lack of causality between co-actor and action effect. Experiment 2 showed that the JSE is absent with an intentional co-actor, but no causality between co-actor and action effect. Our findings indicate an important role of the co-actor's agency for the JSE. They also suggest that the attribution of agency has a strong perceptual basis. PMID:25140144

  16. The joint Simon effect depends on perceived agency, but not intentionality, of the alternative action.

    PubMed

    Stenzel, Anna; Dolk, Thomas; Colzato, Lorenza S; Sellaro, Roberta; Hommel, Bernhard; Liepelt, Roman

    2014-01-01

    A co-actor's intentionality has been suggested to be a key modulating factor for joint action effects like the joint Simon effect (JSE). However, in previous studies intentionality has often been confounded with agency defined as perceiving the initiator of an action as being the causal source of the action. The aim of the present study was to disentangle the role of agency and intentionality as modulating factors of the JSE. In Experiment 1, participants performed a joint go/nogo Simon task next to a co-actor who either intentionally controlled a response button with own finger movements (agency+/intentionality+) or who passively placed the hand on a response button that moved up and down on its own as triggered by computer signals (agency-/intentionality-). In Experiment 2, we included a condition in which participants believed that the co-actor intentionally controlled the response button with a Brain-Computer Interface (BCI) while placing the response finger clearly besides the response button, so that the causal relationship between agent and action effect was perceptually disrupted (agency-/intentionality+). As a control condition, the response button was computer controlled while the co-actor placed the response finger besides the response button (agency-/intentionality-). Experiment 1 showed that the JSE is present with an intentional co-actor and causality between co-actor and action effect, but absent with an unintentional co-actor and a lack of causality between co-actor and action effect. Experiment 2 showed that the JSE is absent with an intentional co-actor, but no causality between co-actor and action effect. Our findings indicate an important role of the co-actor's agency for the JSE. They also suggest that the attribution of agency has a strong perceptual basis.

  17. Public health and bioterrorism: renewed threat of anthrax and smallpox.

    PubMed

    Wallin, Arūne; Luksiene, Zivile; Zagminas, Kestutis; Surkiene, Gene

    2007-01-01

    Bioterrorism is one of the main public health categorical domains. According to sociological analytics, in postmodern society terrorism is one of the real threats of the 21st century. While rare, the use of biological weapons has a long history. Recently, anthrax has been evaluated as one of the most dangerous biological weapons. Naturally occurring anthrax in humans is a disease acquired from contact with anthrax-infected animals or anthrax-contaminated animal products. Usually anthrax infection occurs in humans by three major routes: inhalational, cutaneous, and gastrointestinal. Inhalational anthrax is expected to account for most serious morbidity and most mortality. The clinical presentation of inhalation anthrax has been described as a two-stage illness. Many factors contribute to the pathogenesis of Bacillus anthracis. Antibiotics, anthrax globulin, corticosteroids, mechanical ventilation, vaccine are possible tools of therapy. Smallpox existed in two forms: variola major, which accounted for most morbidity and mortality, and a milder form, variola minor. Smallpox spreads from person to person primarily by droplet nuclei or aerosols expelled from the oropharynx of infected persons and by direct contact. In the event of limited outbreak with few cases, patients should be admitted to the hospital and confined to rooms that are under negative pressure and equipped with high-efficiency particulate air filtration. In larger outbreaks, home isolation and care should be the objective for most patients. Progress in detection, suitable vaccines, postexposure prophylaxis, infection control, and decontamination might be serious tools in fight against the most powerful biological weapon. To assure that the public health and healthcare system can respond to emergencies, the government should direct resources to strengthen the emergency-response system, create medication stockpiles, and improve the public health infrastructure.

  18. Inhaled antibiotics: the new era of personalized medicine?

    PubMed

    Biller, Julie A

    2015-11-01

    Treatment options for individuals with cystic fibrosis (CF) have improved survival significantly over the past two decades. One important treatment modality is inhaled antibiotics to treat chronic infection of the airways. This review includes those antibiotics that are currently in use, those that are in clinical trials. It also includes review of nonantibiotic antimicrobials, a growing area of investigation in CF. There are currently three inhaled antibiotics that are approved for use in patients with cystic fibrosis: tobramycin, aztreonam, and colistimethate. Tobramycin and colistimethate now are available as solution and new dry powder formulations, which are helping the treatment burden which has increased in CF. New antibiotics are in trial, although recently two did not meet primary outcomes in large clinical trials. Of particular interest is the development of nonantibiotic antimicrobials, which may allow treatment of intrinsically antibiotic resistant organisms. Inhaled antibiotics remain an important treatment option in cystic fibrosis due to chronic airway infection as a hallmark of the disease. Although there are now multiple options for treatment, improvements in this treatment class are needed to treat intrinsically resistant organisms. New formulation of antibiotics and nonantibiotic antimicrobials are being evaluated to add to our armamentarium.

  19. Bioavailability of octamethylcyclotetrasiloxane (D(4)) after exposure to silicones by inhalation and implantation.

    PubMed Central

    Luu, H M; Hutter, J C

    2001-01-01

    We developed a physiologically based pharmacokinetic (PBPK) model to predict the target organ doses of octamethylcyclotetrasiloxane (D(4)) after intravenous (IV), inhalation, or implantation exposures. The model used (14)C-D(4) IV disposition data in rats to estimate tissue distribution coefficients, metabolism, and excretion parameters. We validated the model by comparing the predicted blood and tissues concentrations of D(4) after inhalation to experimental results in both rats and humans. We then used the model to simulate D(4) kinetics after single and/or repeated D(4) exposures in rats and humans. The model predicted bioaccumulation of D(4) in fatty tissues (e.g., breast), especially in women. Because of its high lipid solubility (Log P(oct/water) = 5.1), D(4) persisted in fat with a half life of 11.1 days after inhalation and 18.2 days after breast implant exposure. Metabolism and excretion remained constant with repeated exposures, larger doses, and/or different routes of exposure. The accumulation of D(4) in fatty tissues should play an important role in the risk assessment of D(4) especially in women exposed daily to multiple personal care products and silicone breast implants. PMID:11712992

  20. Method Development for the Determination of Free and Esterified Sterols in Button Mushrooms (Agaricus bisporus).

    PubMed

    Hammann, Simon; Vetter, Walter

    2016-05-04

    Ergosterol is the major sterol in button mushrooms (Agaricus bisporus) and can occur as free alcohol or esterified with fatty acids (ergosteryl esters). In this study, gas chromatography with mass spectrometry in the selected ion monitoring mode (GC/MS-SIM) was used to determine ergosterol and ergosteryl esters as well as other sterols and steryl esters in button mushrooms. Different quality control measures were established and sample preparation procedures were compared to prevent the formation of artifacts and the degradation of ergosteryl esters. The final method was then used for the determination of ergosterol (443 ± 44 mg/100 g dry matter (d.m.)) and esterified ergosterol (12 ± 6 mg/100 g d.m.) in button mushroom samples (n = 4). While the free sterol fraction was vastly dominated by ergosterol (∼90% of five sterols in total), the steryl ester fraction was more diversified (nine sterols in total, ergosterol ∼55%) and consisted primarily of linoleic acid esters.

  1. Changes in non-volatile taste components of button mushroom (Agaricus bisporus) during different stages of freeze drying and freeze drying combined with microwave vacuum drying.

    PubMed

    Pei, Fei; Shi, Ying; Gao, Xingyang; Wu, Fangning; Mariga, Alfred Mugambi; Yang, Wenjian; Zhao, Liyan; An, Xinxin; Xin, Zhihong; Yang, Fangmei; Hu, Qiuhui

    2014-12-15

    Button mushroom slices were dehydrated using freeze drying (FD) or FD combined with microwave vacuum drying (FMVD), and the non-volatile component profiles were studied. The results showed that the level of non-volatile components in button mushroom firstly increased during sublimation of FD/FMVD process and then fell during desorption in FD process and MVD in FMVD process. Compared to FD products, the contents of soluble sugars and polyols in FMVD products were relatively low, whereas the contents of total free amino acids were significantly higher, close to the level of fresh mushroom. However, there was no significant difference in the contents of 5'-nucleotides and organic acids between FD and FMVD products. The equivalent umami concentration (EUC) values for FD and FMVD products did not differ from fresh, indicating that both drying methods could effectively preserve MSG (monosodium glutamate)-like components in button mushroom. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. A tool for improving the Web accessibility of visually handicapped persons.

    PubMed

    Fujiki, Tadayoshi; Hanada, Eisuke; Yamada, Tomomi; Noda, Yoshihiro; Antoku, Yasuaki; Nakashima, Naoki; Nose, Yoshiaki

    2006-04-01

    Abstract Much has been written concerning the difficulties faced by visually handicapped persons when they access the internet. To solve some of the problems and to make web pages more accessible, we developed a tool we call the "Easy Bar," which works as a toolbar on the web browser. The functions of the Easy Bar are to change the size of web texts and images, to adjust the color, and to clear cached data that is automatically saved by the web browser. These functions are executed with ease by clicking buttons and operating a pull-down list. Since the icons built into Easy Bar are quite large, it is not necessary for the user to deal with delicate operations. The functions of Easy Bar run on any web page without increasing the processing time. For the visually handicapped, Easy Bar would contribute greatly to improved web accessibility to medical information.

  3. 28 CFR 79.41 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... includes in situ lung cancers. (j) Readily available documentation means documents in the possession... or uranium mine worker means a person who operated or otherwise worked in a uranium mine. (f... means a chronic lung disease resulting from inhalation and deposition in the lung of particulate matter...

  4. Experimental analysis of surface finish in normal conducting cavities

    NASA Astrophysics Data System (ADS)

    Zarrebini-Esfahani, A.; Aslaninejad, M.; Ristic, M.; Long, K.

    2017-10-01

    A normal conducting 805 MHz test cavity with an in built button shaped sample is used to conduct a series of surface treatment experiments. The button enhances the local fields and influences the likelihood of an RF breakdown event. Because of their smaller sizes, compared to the whole cavity surface, they allow practical investigations of the effects of cavity surface preparation in relation to RF breakdown. Manufacturing techniques and steps for preparing the buttons to improve the surface quality are described in detail. It was observed that even after the final stage of the surface treatment, defects on the surface of the cavities still could be found.

  5. Key Aroma Compounds in Lippia dulcis (Dushi Button).

    PubMed

    Schmitt, Rainer; Cappi, Michael; Pollner, Gwendola; Greger, Veronika

    2018-03-14

    An aroma extract dilution analysis (AEDA) applied on aroma extracts prepared from the edible flower Dushi Button ( Lippia dulcis) resulted in the detection of 34 odor-active compounds. The highest flavor dilution (FD) factors were determined for methyl 2-methylbutanoate, ethyl 2-methylbutanoate, 4-mercapto-4-methyl-2-pentanone, an unknown caramel-like compound, and vanillin. Quantitative measurements performed by application of stable isotope dilution assays (SIDA), followed by a calculation of odor activity values (OAVs), resulted in the revelation of 4-mercapto-4-methyl-2-pentanone, linalool, myrcene, ethyl 2-methylbutanoate, methyl 2-methylbutanoate, and ( Z)-3-hexenal as important contributors to the flavor of Dushi Buttons.

  6. Investigations of the historic textiles excavated from Ancient Ainos (Enez - Turkey) by multiple analytical techniques

    NASA Astrophysics Data System (ADS)

    Akyuz, Sevim; Akyuz, Tanil; Cakan, Banu; Basaran, Sait

    2014-09-01

    Some metal ornamented textile specimens and a textile button, excavated from Ancient Ainos (Enez - Turkey), have been investigated using FTIR and EDXRF spectrometry, for the purpose of material identification. FTIR spectral results indicated that textiles were made from partially degummed Bombyx mori silk. The IR spectral investigation of the textile button revealed that some cellulose fillings were used inside the button. The EDXRF analysis of the metal ornaments showed that they were silver plated copper. Surface morphology of the textiles and the metal ornaments were investigated by SEM images. It was shown that textile fibers were highly degraded.

  7. Biological effects of cigarette smoke, wood smoke, and the smoke from plastics: the use of electron spin resonance.

    PubMed

    Pryor, W A

    1992-12-01

    This review compares and contrasts the chemistry of cigarette smoke, wood smoke, and the smoke from plastics and building materials that is inhaled by persons trapped in fires. Cigarette smoke produces cancer, emphysema, and other diseases after a delay of years. Acute exposure to smoke in a fire can produce a loss of lung function and death after a delay of days or weeks. Tobacco smoke and the smoke inhaled in a burning building have some similarities from a chemical viewpoint. For example, both contain high concentrations of CO and other combustion products. In addition, both contain high concentrations of free radicals, and our laboratory has studied these free radicals, largely by electron spin resonance (ESR) methods, for about 15 years. This article reviews what is known about the radicals present in these different types of smokes and soots and tars and summarizes the evidence that suggests these radicals could be involved in cigarette-induced pathology and smoke-inhalation deaths. The combustion of all organic materials produces radicals, but (with the exception of the smoke from perfluoropolymers) the radicals that are detected by ESR methods (and thus the radicals that would reach the lungs) are not those that arise in the combustion process. Rather they arise from chemical reactions that occur in the smoke itself. Thus, a knowledge of the chemistry of the smoke is necessary to understand the nature of the radicals formed. Even materials as similar as cigarettes and wood (cellulose) produce smoke that contains radicals with very different lifetimes and chemical characteristics, and mechanistic rationales for this are discussed. Cigarette tar contains a semiquinone radical that is infinitely stable and can be directly observed by ESR. Aqueous extracts of cigarette tar, which contain this radical, reduce oxygen to superoxide and thus produce both hydrogen peroxide and the hydroxyl radical. These solutions both oxidize alpha-1-proteinase inhibitor (a1PI) and nick DNA. Because of the potential role of radicals in smoke-inhalation injury, we suggest that antioxidant therapy (such as use of an inhaler for persons brought out of a burning building) might prove efficacious.

  8. Dermal, inhalation, and internal exposure to 1,6‐HDI and its oligomers in car body repair shop workers and industrial spray painters

    PubMed Central

    Pronk, A; Yu, F; Vlaanderen, J; Tielemans, E; Preller, L; Bobeldijk, I; Deddens, J A; Latza, U; Baur, X; Heederik, D

    2006-01-01

    Objectives To study inhalation and dermal exposure to hexamethylene diisocyanate (HDI) and its oligomers as well as personal protection equipment (PPE) use during task performance in conjunction with urinary hexamethylene diamine (HDA) in car body repair shop workers and industrial spray painters. Methods Personal task based inhalation samples (n = 95) were collected from six car body repair shops and five industrial painting companies using impingers with di‐n‐butylamine (DBA) in toluene. In parallel, dermal exposure was assessed using nitril rubber gloves. Gloves were submerged into DBA in toluene after sampling. Analysis for HDI and its oligomers was performed by LC‐MS/MS. Urine samples were collected from 55 workers (n = 291) and analysed for HDA by GC‐MS. Results Inhalation exposure was strongly associated with tasks during which aerosolisation occurs. Dermal exposure occurred during tasks that involve direct handling of paint. In car body repair shops associations were found between detectable dermal exposure and glove use (odds ratio (OR) 0.22, 95% confidence interval (CI) 0.09 to 0.57) and inhalation exposure level (OR 1.34, 95% CI 0.97 to 1.84 for a 10‐fold increase). HDA in urine could be demonstrated in 36% and 10% of car body repair shop workers and industrial painting company workers respectively. In car body repair shops, the frequency of detectable HDA was significantly elevated at the end of the working day (OR 2.13, 95% CI 1.07 to 4.22 for 3–6 pm v 0–8 am). In both branches HDA was detected in urine of ∼25% of the spray painters. In addition HDA was detected in urine of a large proportion of non‐spray painters in car body repair shops. Conclusion Although (spray) painting with lacquers containing isocyanate hardeners results in the highest external exposures to HDI and oligomers, workers that do not perform paint related tasks may also receive a considerable internal dose. PMID:16728504

  9. Hybrid: Braking

    Science.gov Websites

    Button Stopped button highlighted subbanner graphic: gray bar STOPPED When the vehicle is stopped engine when additional power is needed. It also acts as a generator, converting energy from the engine or engine instantly when needed. Main stage: See through car with battery, engine, and electric motor

  10. Armpits, Belly Buttons and Chronic Wounds: The ABCs of Our Body Bacteria

    MedlinePlus

    ... Wounds: The ABCs of Our Body Bacteria Inside Life Science View All Articles | Inside Life Science Home Page Armpits, Belly Buttons and Chronic Wounds: ... Other Findings About Our Resident Microbes This Inside Life Science article also appears on LiveScience . Learn about related ...

  11. Direct manipulation of virtual objects

    NASA Astrophysics Data System (ADS)

    Nguyen, Long K.

    Interacting with a Virtual Environment (VE) generally requires the user to correctly perceive the relative position and orientation of virtual objects. For applications requiring interaction in personal space, the user may also need to accurately judge the position of the virtual object relative to that of a real object, for example, a virtual button and the user's real hand. This is difficult since VEs generally only provide a subset of the cues experienced in the real world. Complicating matters further, VEs presented by currently available visual displays may be inaccurate or distorted due to technological limitations. Fundamental physiological and psychological aspects of vision as they pertain to the task of object manipulation were thoroughly reviewed. Other sensory modalities -- proprioception, haptics, and audition -- and their cross-interactions with each other and with vision are briefly discussed. Visual display technologies, the primary component of any VE, were canvassed and compared. Current applications and research were gathered and categorized by different VE types and object interaction techniques. While object interaction research abounds in the literature, pockets of research gaps remain. Direct, dexterous, manual interaction with virtual objects in Mixed Reality (MR), where the real, seen hand accurately and effectively interacts with virtual objects, has not yet been fully quantified. An experimental test bed was designed to provide the highest accuracy attainable for salient visual cues in personal space. Optical alignment and user calibration were carefully performed. The test bed accommodated the full continuum of VE types and sensory modalities for comprehensive comparison studies. Experimental designs included two sets, each measuring depth perception and object interaction. The first set addressed the extreme end points of the Reality-Virtuality (R-V) continuum -- Immersive Virtual Environment (IVE) and Reality Environment (RE). This validated, linked, and extended several previous research findings, using one common test bed and participant pool. The results provided a proven method and solid reference points for further research. The second set of experiments leveraged the first to explore the full R-V spectrum and included additional, relevant sensory modalities. It consisted of two full-factorial experiments providing for rich data and key insights into the effect of each type of environment and each modality on accuracy and timeliness of virtual object interaction. The empirical results clearly showed that mean depth perception error in personal space was less than four millimeters whether the stimuli presented were real, virtual, or mixed. Likewise, mean error for the simple task of pushing a button was less than four millimeters whether the button was real or virtual. Mean task completion time was less than one second. Key to the high accuracy and quick task performance time observed was the correct presentation of the visual cues, including occlusion, stereoscopy, accommodation, and convergence. With performance results already near optimal level with accurate visual cues presented, adding proprioception, audio, and haptic cues did not significantly improve performance. Recommendations for future research include enhancement of the visual display and further experiments with more complex tasks and additional control variables.

  12. 78 FR 32081 - Airworthiness Directives; Aircraft Industries a.s. Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-29

    ... Injection System WATER INJECTION circuit ON breakter. TCL TQ=min. 60% WATER INJECTION/ON push- Push and hold till amber button. WATER INJECTION signal comes on (on the front control panel) Before throttling back power: WATER INJECTION/OFF push- Push and check amber button. WATER INJECTION signal extinguishes...

  13. Adapting the eButton to the abilities of children for diet assessment

    USDA-ARS?s Scientific Manuscript database

    Dietary assessment is fraught with error among adults and especially among children. Innovative technology may provide more accurate assessments of dietary intake. One recently available innovative method is a camera worn on the chest (called an eButton) that takes images of whatever is in front of ...

  14. Dietary supplementation with white button mushroom augments the protective immune response to Salmonella vaccine in mice

    USDA-ARS?s Scientific Manuscript database

    We previously showed that dietary white button mushrooms (WBM) enhanced natural killer cell activity and that in vitro WBM supplementation promotes maturation and function of dendritic cells (DC). The current study investigated whether WBM consumption would enhance pathogen-specific immune response ...

  15. James Webb Telescope

    Science.gov Websites

    . solarsystem mobile thumbnail solarystem mobile button Webb will monitor the weather and atmospheres of the mobile thumbnail exoplanets-weather mobile button Webb will search for signs of life-sustaining water on planets beyond our solar system, and help us learn how planets form. blackholes mobile thumbnail

  16. The Haida Button Blanket.

    ERIC Educational Resources Information Center

    Johnson, Vesta

    In the Haida nation, there are two phratries, Eagle and Raven, divided into a number of clans sharing one or more emblems. These emblems, inherited from the mother's line, adorn the button blankets which are the traditional ceremonial robes that serve to identify the family of the wearer. Written instructions and diagrams guide students in…

  17. NHEXAS PHASE I REGION 5 STUDY--METALS IN DUST ANALYTICAL RESULTS

    EPA Science Inventory

    This data set includes analytical results for measurements of metals in 1,906 dust samples. Dust samples were collected to assess potential residential sources of dermal and inhalation exposures and to examine relationships between analyte levels in dust and in personal and bioma...

  18. Rhabdomyolysis with acute tubular necrosis following occupational inhalation of thinners.

    PubMed

    Ngajilo, D; Ehrlich, R

    2017-07-01

    Thinners are mixtures of organic solvents commonly containing toluene, xylene, acetone, hexane, benzene and methyl isobutyl ketone. This report describes a case of rhabdomyolysis with acute tubular necrosis and renal failure, most likely attributable to toluene, following occupational exposure to thinners while cleaning a steel water tank. These adverse health effects have previously been reported following acute poisoning or intentional inhalation by drug abusers, but rarely in the occupational setting. Poor working conditions, lack of health and safety training and delayed treatment contributed to the onset and severity of the patient's complications. This case emphasizes the need for strict control measures, including adequate ventilation, training on working in confined spaces, appropriate personal protective equipment and emergency rescue procedures in such settings. In addition, rhabdomyolysis, acute tubular necrosis and renal failure should be added to safety data material as possible complications of excessive inhalation of thinners. © The Author 2017. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Size-Dependent Deposition, Translocation, and Microglial Activation of Inhaled Silver Nanoparticles in the Rodent Nose and Brain

    PubMed Central

    Patchin, Esther Shin; Anderson, Donald S.; Silva, Rona M.; Uyeminami, Dale L.; Scott, Grace M.; Guo, Ting; Van Winkle, Laura S.; Pinkerton, Kent E.

    2016-01-01

    Background: Silver nanoparticles (AgNP) are present in personal, commercial, and industrial products, which are often aerosolized. Current understanding of the deposition, translocation, and health-related impacts of AgNP inhalation is limited. Objectives: We determined a) the deposition and retention of inhaled Ag in the nasal cavity from nose-only exposure; b) the timing for Ag translocation to and retention/clearance in the olfactory bulb (OB); and c) whether the presence of Ag in the OB affects microglial activity. Methods: Male Sprague-Dawley rats were exposed nose-only to citrate-buffered 20- or 110-nm AgNP (C20 or C110, respectively) or citrate buffer alone for 6 hr. The nasal cavity and OB were examined for the presence of Ag and for biological responses up to 56 days post-exposure (8 weeks). Results: The highest nasal Ag deposition was observed on Day 0 for both AgNP sizes. Inhalation of aerosolized C20 resulted in rapid translocation of Ag to the OB and in microglial activation at Days 0, 1, and 7. In contrast, inhalation of C110 resulted in a gradual but progressive transport of Ag to and retention in the OB, with a trend for microglial activation to variably be above control. Conclusions: The results of this study show that after rats experienced a 6-hr inhalation exposure to 20- and 110-nm AgNP at a single point in time, Ag deposition in the nose, the rate of translocation to the brain, and subsequent microglial activation in the OB differed depending on AgNP size and time since exposure. Citation: Patchin ES, Anderson DS, Silva RM, Uyeminami DL, Scott GM, Guo T, Van Winkle LS, Pinkerton KE. 2016. Size-dependent deposition, translocation, and microglial activation of inhaled silver nanoparticles in the rodent nose and brain. Environ Health Perspect 124:1870–1875; http://dx.doi.org/10.1289/EHP234 PMID:27152509

  20. [Personal emergency call system based on human vital and system technical parameters in a Smart Home environment].

    PubMed

    Hampicke, M; Schadow, B; Rossdeutscher, W; Fellbaum, K; Boenick, U

    2002-11-01

    Progress in microtechnology and radio transmission technology has enabled the development of highly reliable emergency-call systems. The present article describes systems that have been specially designed to improve the safety and independence of handicapped and elderly persons living at home. For such persons immediate help in an emergency situation is of crucial importance. The technical state of the art of emergency-call systems specially developed for use by the elderly, is briefly discussed, in particular the well-known radio emergency-call button, with the aid of which an alarm can be activated manually. This system, however, does not offer adequate safety in all emergency situations. Alternative or complementary systems designed to automatically trigger an alarm on the basis of the recording and evaluation of so-called vital parameters, are therefore proposed. In addition, in a smart-home environment with networked devices, further parameters--so-called environment parameters can be used. It is found that the identification of an emergency situation becomes more reliable as the number of parameters employed increases.

  1. The Button Project

    ERIC Educational Resources Information Center

    Armstrong, Charley

    2005-01-01

    In this article, the author describes The Button Project. It started as a dream, a need to educate future generations about the Holocaust, to teach tolerance, and to remember the past. Under the auspices of the Jewish Federation of Peoria, a small band of people joined together with the goal of teaching people about the Holocaust so that it will…

  2. Utility of eButton images for identifying food preparation behaviors and meal-related tasks in adolescents

    USDA-ARS?s Scientific Manuscript database

    Food preparation skills may encourage healthy eating. Traditional assessment of child food preparation employs self- or parent proxy-reporting methods, which are prone to error. The eButton is a wearable all-day camera that has promise as an objective, passive method for measuring child food prepara...

  3. 31. VIEW OF A WORKER HOLDING A PLUTONIUM 'BUTTON.' PLUTONIUM, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    31. VIEW OF A WORKER HOLDING A PLUTONIUM 'BUTTON.' PLUTONIUM, A MAN-MADE SUBSTANCE, WAS RARE. SCRAPS RESULTING FROM PRODUCTION AND PLUTONIUM RECOVERED FROM RETIRED NUCLEAR WEAPONS WERE REPROCESSED INTO VALUABLE PURE-PLUTONIUM METAL (9/19/73). - Rocky Flats Plant, Bounded by Indiana Street & Routes 93, 128 & 72, Golden, Jefferson County, CO

  4. "Urgency tip": a portable patient-activated device for objective measurement of urinary urgency.

    PubMed

    Kobayashi, Hideki; Araki, Isao; Tsuchida, Takayuki; Zakoji, Hidenori; Mikami, Yuki; Takeda, Masayuki; Kiyohiro, Noriaki

    2007-03-01

    For clinical practice and research of overactive bladder syndrome, it is essential to evaluate urgency symptoms in daily life. We have developed a portable patient-activated device to record bladder sensations. This electronic device is pocket-size and light, with five grading buttons and another button for cancellation.

  5. 46 CFR 121.510 - Recommended emergency broadcast instructions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Immediate Danger to Life or Property. (4) Say: “THIS IS (INSERT VESSEL'S NAME), (INSERT VESSEL'S NAME), (INSERT VESSEL'S NAME), (INSERT VESSEL'S CALL SIGN), OVER.” (5) Release the microphone button briefly and... 16 VHF and 2182 kHz on SSB are for emergency and calling purposes only.) (3) Press microphone button...

  6. Harvesting keratolimbal allografts from corneoscleral buttons: a novel application of cyanoacrylate adhesive.

    PubMed

    Lim, L T; Bhatt, P R; Ramaesh, K

    2008-11-01

    To describe an alternative and novel technique using cyanoacrylate glue to achieve successful limbal tissue dissection, from an organ culture media stored corneoscleral button, without an artificial anterior chamber. A donor corneoscleral button (leftover from penetrating keratoplasty) was divided into two equal semicircular halves. A thick layer of tissue adhesive (N-butyl-2-cyanoacrylate) was spread on a sterile rubber block (the under surface of the donor punch). One half of the donor corneoscleral rim was placed epithelial side up on the adhesive and allowed to attach firmly to the block. This composite provided stability to the donor rim allowing lamellar dissection of the limbal tissue to be performed without damaging the limbal epithelium. Regular, partial-thickness limbal tissue was obtained. There was no histological evidence of glue or cellular toxicity of the harvested limbal stem cells. This harvested tissue had been grafted successfully in patients with limbal stem cell deficiency also undergoing keratoplasty. Tissue adhesive can be a simple, effective and useful tool in the dissection and harvesting of corneal limbal stem cell allografts from corneoscleral buttons stored in organ culture media.

  7. Enhancing stability of essential oils by microencapsulation for preservation of button mushroom during postharvest

    PubMed Central

    Alikhani-Koupaei, Majid; Mazlumzadeh, Meisam; Sharifani, Mohamadmehdi; Adibian, Mohamad

    2014-01-01

    Fresh button mushrooms (Agaricus bisporus L.) are sensitive to browning, water loss, and microbial attack. The short shelf-life of mushrooms is an impediment to the distribution and marketing of the fresh product. Essential oils outstand as an alternative to chemical preservatives and their use in foods meets the demands of consumers for natural products. To resolve controlled release of oil and increase in antioxidant and antimicrobial activities, the oil was incorporated into microcapsules. Effects of microcapsulated thyme (Thymus vulgaris L.) and rosemary (Rosmarinus officinalis L.) on quality of fresh button mushroom were compared. Physicochemical qualities were evaluated during 15 days of storage at 4 ± 0.5°C. All treatments prevented product weight loss and decrease in polyphenoloxidase and peroxidase activities during storage. Color and firmness, microbiological analysis, and total phenolic content caused the least change. With use of microencapsulated oils, mushrooms were within acceptable limits during 10 days of storage. Microencapsulated rosemary oil produced the highest beneficial effects and has potential to improve quality of button mushrooms and extend shelf-life. PMID:25473510

  8. Further miniaturisation of the Thermochron iButton to create a thermal bio-logger weighing 0.3 g.

    PubMed

    Virens, Josef; Cree, Alison

    2018-06-05

    Thermochron iButtons are commonly used by thermal biologists to continuously measure body temperature from animals. However, if unmodified, these devices are of a size that limits their use with very small animals. To allow iButtons to be used to study smaller species, methods to miniaturise them by 61% have been previously described. We present a method to reduce iButton mass by a further 71%. The modified devices have a shorter battery life, but the minimum size of vertebrates able to carry the devices is reduced from 28.9 g to 6.6 g, if the arbitrary, yet widely cited, maximum of 5% body mass for attached devices is adhered to. We demonstrate the application of our method by recording surface temperatures of captive and wild skinks and show that captive cockroaches weighing 0.8 g are also able to carry the device. We believe this to be the first time that temperature data have been recorded from an insect in this way. © 2018. Published by The Company of Biologists Ltd.

  9. Aniridia-related keratopathy: Structural changes in naïve and transplanted corneal buttons

    PubMed Central

    Stenevi, Ulf; Pedrosa Domellöf, Fátima

    2018-01-01

    Background To study structural changes in naïve and surgically treated corneas of aniridia patients with advanced aniridia-related keratopathy (ARK). Methods and findings Two naïve corneal buttons from patients with advanced ARK submitted to penetrating keratoplasty for the first time, one corneal button from an ARK patient that had undergone a keratolimbal allograft (KLAL), two corneal buttons from ARK patients who had previously undergone centered or decentered transplantation and were now retransplanted and two adult healthy donor control corneas were processed for immunohistochemistry. Antibodies against extracellular matrix components in the stroma and in the epithelial basement membrane (collagen I and IV, collagen receptor α11 integrin and laminin α3 chain), markers of fibrosis, wound healing and vascularization (fibronectin, tenascin-C, vimentin, α-SMA and caveolin-1), cell division (Ki-67) and macrophages (CD68) were used. Naïve ARK, KLAL ARK corneas and transplanted corneal buttons presented similar histopathological changes with irregular epithelium and disruption or absence of epithelial basal membrane. There was a loss of the orderly pattern of collagen lamellae and absence of collagen I in all ARK corneas. Vascularization was revealed by the presence of caveolin-1 and collagen IV in the pannus of all ARK aniridia corneas. The changes observed in decentered and centered transplants were analogous. Conclusions Given the similar pathological features of all cases, conditions inherent to the host seem to play an important role on the pathophysiology of the ARK in the long run. PMID:29889891

  10. Aniridia-related keratopathy: Structural changes in naïve and transplanted corneal buttons.

    PubMed

    Vicente, André; Byström, Berit; Lindström, Mona; Stenevi, Ulf; Pedrosa Domellöf, Fátima

    2018-01-01

    To study structural changes in naïve and surgically treated corneas of aniridia patients with advanced aniridia-related keratopathy (ARK). Two naïve corneal buttons from patients with advanced ARK submitted to penetrating keratoplasty for the first time, one corneal button from an ARK patient that had undergone a keratolimbal allograft (KLAL), two corneal buttons from ARK patients who had previously undergone centered or decentered transplantation and were now retransplanted and two adult healthy donor control corneas were processed for immunohistochemistry. Antibodies against extracellular matrix components in the stroma and in the epithelial basement membrane (collagen I and IV, collagen receptor α11 integrin and laminin α3 chain), markers of fibrosis, wound healing and vascularization (fibronectin, tenascin-C, vimentin, α-SMA and caveolin-1), cell division (Ki-67) and macrophages (CD68) were used. Naïve ARK, KLAL ARK corneas and transplanted corneal buttons presented similar histopathological changes with irregular epithelium and disruption or absence of epithelial basal membrane. There was a loss of the orderly pattern of collagen lamellae and absence of collagen I in all ARK corneas. Vascularization was revealed by the presence of caveolin-1 and collagen IV in the pannus of all ARK aniridia corneas. The changes observed in decentered and centered transplants were analogous. Given the similar pathological features of all cases, conditions inherent to the host seem to play an important role on the pathophysiology of the ARK in the long run.

  11. Utility of eButton images for identifying food preparation behaviors and meal-related tasks in adolescents.

    PubMed

    Raber, Margaret; Patterson, Monika; Jia, Wenyan; Sun, Mingui; Baranowski, Tom

    2018-02-24

    Food preparation skills may encourage healthy eating. Traditional assessment of child food preparation employs self- or parent proxy-reporting methods, which are prone to error. The eButton is a wearable all-day camera that has promise as an objective, passive method for measuring child food preparation practices. This paper explores the feasibility of the eButton to reliably capture home food preparation behaviors and practices in a sample of pre- and early adolescents (ages 9 to 13). This is a secondary analysis of two eButton pilot projects evaluating the dietary intake of pre- and early adolescents in or around Houston, Texas. Food preparation behaviors were coded into seven major categories including: browsing, altering food/adding seasoning, food media, meal related tasks, prep work, cooking and observing. Inter-coder reliability was measured using Cohen's kappa and percent agreement. Analysis was completed on data for 31 participants. The most common activity was browsing in the pantry or fridge. Few participants demonstrated any food preparation work beyond unwrapping of food packages and combining two or more ingredients; actual cutting or measuring of foods were rare. Although previous research suggests children who "help" prepare meals may obtain some dietary benefit, accurate assessment tools of food preparation behavior are lacking. The eButton offers a feasible approach to food preparation behavior measurement among pre- and early adolescents. Follow up research exploring the validity of this method in a larger sample, and comparisons between cooking behavior and dietary intake are needed.

  12. Fixation of the Achilles tendon insertion using suture button technology.

    PubMed

    Fanter, Nathan J; Davis, Edward W; Baker, Champ L

    2012-09-01

    In the operative treatment of Achilles insertional tendinopathy, no guidelines exist concerning which form of fixation of the Achilles tendon insertion is superior. Transcalcaneal drill pin passage does not place any major plantar structures at risk, and the addition of a Krackow stitch and suture button to the fixation technique provides a significant increase in ultimate load to failure in Achilles tendon insertional repairs. Controlled laboratory study. The Achilles tendon insertions in 6 fresh-frozen cadaveric ankles were detached, and transcalcaneal drill pins were passed. Plantar dissection took place to evaluate the drill pin relationship to the plantar fascia, lateral plantar nerve and artery, flexor digitorum longus tendon, and master knot of Henry. The Achilles tendons were then repaired with a double-row suture anchor construct alone or with a suture button and Krackow stitch added to the double-row suture anchor construct. The repairs were then tested to maximum load to failure at 20 mm/min. The mode of failure was recorded, and the mean maximum load to failure was assessed using the Student t test for distributions with equal variance. Transcalcaneal drill pin passage did not place any selected anatomic structures at risk. The mean maximum load to failure for the suture bridge group was 239.2 N; it was 391.4 N for the group with the suture button (P = .014). The lateral plantar artery was the structure placed at greatest risk from drill pin placement, with a mean distance of 22.7 mm (range, 16.5-29.2 mm) between the pin and artery. In this laboratory study, transcalcaneal drill pin passage appeared to be anatomically safe, and the use of suture button technology with a Krackow stitch for Achilles tendon insertional repair significantly increased repair strength. Achilles tendon insertional repair with suture button fixation and a Krackow stitch may facilitate the earlier institution of postoperative rehabilitation and improve clinical outcomes.

  13. A personalized medicine approach to the design of dry powder inhalers: Selecting the optimal amount of bypass.

    PubMed

    Kopsch, Thomas; Murnane, Darragh; Symons, Digby

    2017-08-30

    In dry powder inhalers (DPIs) the patient's inhalation manoeuvre strongly influences the release of drug. Drug release from a DPI may also be influenced by the size of any air bypass incorporated in the device. If the amount of bypass is high less air flows through the entrainment geometry and the release rate is lower. In this study we propose to reduce the intra- and inter-patient variations of drug release by controlling the amount of air bypass in a DPI. A fast computational method is proposed that can predict how much bypass is needed for a specified drug delivery rate for a particular patient. This method uses a meta-model which was constructed using multiphase computational fluid dynamic (CFD) simulations. The meta-model is applied in an optimization framework to predict the required amount of bypass needed for drug delivery that is similar to a desired target release behaviour. The meta-model was successfully validated by comparing its predictions to results from additional CFD simulations. The optimization framework has been applied to identify the optimal amount of bypass needed for fictitious sample inhalation manoeuvres in order to deliver a target powder release profile for two patients. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Estimation of the Human Extrathoracic Deposition Fraction of Inhaled Particles Using a Polyurethane Foam Collection Substrate in an IOM Sampler.

    PubMed

    Sleeth, Darrah K; Balthaser, Susan A; Collingwood, Scott; Larson, Rodney R

    2016-03-07

    Extrathoracic deposition of inhaled particles (i.e., in the head and throat) is an important exposure route for many hazardous materials. Current best practices for exposure assessment of aerosols in the workplace involve particle size selective sampling methods based on particle penetration into the human respiratory tract (i.e., inhalable or respirable sampling). However, the International Organization for Standardization (ISO) has recently adopted particle deposition sampling conventions (ISO 13138), including conventions for extrathoracic (ET) deposition into the anterior nasal passage (ET₁) and the posterior nasal and oral passages (ET₂). For this study, polyurethane foam was used as a collection substrate inside an inhalable aerosol sampler to provide an estimate of extrathoracic particle deposition. Aerosols of fused aluminum oxide (five sizes, 4.9 µm-44.3 µm) were used as a test dust in a low speed (0.2 m/s) wind tunnel. Samplers were placed on a rotating mannequin inside the wind tunnel to simulate orientation-averaged personal sampling. Collection efficiency data for the foam insert matched well to the extrathoracic deposition convention for the particle sizes tested. The concept of using a foam insert to match a particle deposition sampling convention was explored in this study and shows promise for future use as a sampling device.

  15. Estimation of the Human Extrathoracic Deposition Fraction of Inhaled Particles Using a Polyurethane Foam Collection Substrate in an IOM Sampler

    PubMed Central

    Sleeth, Darrah K.; Balthaser, Susan A.; Collingwood, Scott; Larson, Rodney R.

    2016-01-01

    Extrathoracic deposition of inhaled particles (i.e., in the head and throat) is an important exposure route for many hazardous materials. Current best practices for exposure assessment of aerosols in the workplace involve particle size selective sampling methods based on particle penetration into the human respiratory tract (i.e., inhalable or respirable sampling). However, the International Organization for Standardization (ISO) has recently adopted particle deposition sampling conventions (ISO 13138), including conventions for extrathoracic (ET) deposition into the anterior nasal passage (ET1) and the posterior nasal and oral passages (ET2). For this study, polyurethane foam was used as a collection substrate inside an inhalable aerosol sampler to provide an estimate of extrathoracic particle deposition. Aerosols of fused aluminum oxide (five sizes, 4.9 µm–44.3 µm) were used as a test dust in a low speed (0.2 m/s) wind tunnel. Samplers were placed on a rotating mannequin inside the wind tunnel to simulate orientation-averaged personal sampling. Collection efficiency data for the foam insert matched well to the extrathoracic deposition convention for the particle sizes tested. The concept of using a foam insert to match a particle deposition sampling convention was explored in this study and shows promise for future use as a sampling device. PMID:26959046

  16. Exposures to quartz, diesel, dust, and welding fumes during heavy and highway construction.

    PubMed

    Woskie, Susan R; Kalil, Andrew; Bello, Dhimiter; Virji, M Abbas

    2002-01-01

    Personal samples for exposure to dust, diesel exhaust, quartz, and welding fume were collected on heavy and highway construction workers. The respirable, thoracic, and inhalable fractions of dust and quartz exposures were estimated from 260 personal impactor samples. Respirable quartz exposures exceeded the National Institute for Occupational Safety and Health (NIOSH) recommended exposure limit (REL) in 7-31% of cases for the trades sampled. More than 50% of the samples in the installation of drop ceilings and wall tiles and concrete finish operations exceeded the NIOSH REL for quartz. Thoracic exposures to quartz and dust exceeded respirable exposures by a factor of 4.5 and 2.8, respectively. Inhalable exposures to quartz and dust exceeded respirable exposures by a factor of 25.6 and 9.3, respectively. These findings are important due to the identification of quartz as a carcinogen by the National Toxicology Program and the International Agency for Research on Cancer. Fourteen percent of the personal samples for EC (n = 261), collected as a marker for diesel exhaust, exceeded the American Conference of Governmental Industrial Hygienists (ACGIH) threshold limit value (TLV) for diesel exhaust. Seventeen of the 22 (77%) samples taken during a partially enclosed welding operation reached or exceeded the ACGIH TLV of 5 mg/m3 for welding fume.

  17. Napoleon's Buttons: Teaching the Role of Chemistry in History

    ERIC Educational Resources Information Center

    Samet, Cindy; Higgins, Pamela J.

    2005-01-01

    A course designed on the theme of Napoleon's Buttons, which states that there is a connection between the chemical structure of a compound and its pivotal moments in history affecting the development of society is explained. Students liked the book choice for the course because the focus was not on straight chemistry, but the intersection of…

  18. Designing a Machinery Control System (MCS) Security Testbed

    DTIC Science & Technology

    2014-09-01

    IO LAB” button and verify the display looks as follows: 95 Figure F22 . “Ready State” (and start state)of the DIOL as displayed at the HMI...After verification that the HMI screen looks like Figure F22 , click on the “Back to Home Screen” button and return to the HMI “Home” screen as seen

  19. 78 FR 66099 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-04

    ... every year (a) by an ophthalmologist or optometrist who attests that the vision in the better eye... showing that the vision in the better eye continues to meet the requirement specified at 49 CFR 391.41(b... click the search button. When the new screen appears, click on the blue ``Comment Now!'' button on the...

  20. Peach fruit set and buttoning after spring frost

    USDA-ARS?s Scientific Manuscript database

    A spring frost occurred on 29 Mar. 2015 at the USDA-ARS Byron station after three weeks of blooming when most fruitlets were forming. Due to severe fruitlet drop, the overall fruit set on a scale of 0-9 was substantially reduced, from 5.61 averaged in 2014 to 2.61 in 2015. In addition, buttons (abno...

  1. Mechanical Design of Metal Dome for Industrial Application

    NASA Astrophysics Data System (ADS)

    Jin-Chee Liu, Thomas; Chen, Li-Wei; Lin, Nai-Pin

    2018-02-01

    In this paper, the mechanical design of metal domes is studied using finite element analysis. The snap-through behavior of a practical button design that uses a metal dome is found. In addition, the individual click ratio and maximum force for a variety of metal domes are determined. This paper provides guidance on button design for industrial engineers.

  2. Tube support

    DOEpatents

    Mullinax, Jerry L.

    1988-01-01

    A tube support for supporting horizontal tubes from an inclined vertical support tube passing between the horizontal tubes. A support button is welded to the vertical support tube. Two clamping bars or plates, the lower edges of one bearing on the support button, are removably bolted to the inclined vertical tube. The clamping bars provide upper and lower surface support for the horizontal tubes.

  3. The Newport Button: The Large Scale Replication Of Combined Three-And Two-Dimensional Holographic Images

    NASA Astrophysics Data System (ADS)

    Cowan, James J.

    1984-05-01

    A unique type of holographic imagery and its large scale replication are described. The "Newport Button", which was designed as an advertising premium item for the Newport Corporation, incorporates a complex overlay of holographic diffraction gratings surrounding a three-dimensional holographic image of a real object. The combined pattern is recorded onto a photosensitive medium from which a metal master is made. The master is subsequently used to repeatedly emboss the pattern into a thin plastic sheet. Individual patterns are then die cut from the metallized plastic and mounted onto buttons. A discussion is given of the diffraction efficiencies of holograms made in this particular fashion and of the special requirements of the replication process.

  4. Personal exposure to Black Carbon in transport microenvironments

    NASA Astrophysics Data System (ADS)

    Dons, Evi; Int Panis, Luc; Van Poppel, Martine; Theunis, Jan; Wets, Geert

    2012-08-01

    We evaluated personal exposure of 62 individuals to the air pollutant Black Carbon, using 13 portable aethalometers while keeping detailed records of their time-activity pattern and whereabouts. Concentrations encountered in transport are studied in depth and related to trip motives. The evaluation comprises more than 1500 trips with different transport modes. Measurements were spread over two seasons. Results show that 6% of the time is spent in transport, but it accounts for 21% of personal exposure to Black Carbon and approximately 30% of inhaled dose. Concentrations in transport were 2-5 times higher compared to concentrations encountered at home. Exposure was highest for car drivers, and car and bus passengers. Concentrations of Black Carbon were only half as much when traveling by bike or on foot; when incorporating breathing rates, dose was found to be twice as high for active modes. Lowest 'in transport' concentrations were measured in trains, but nevertheless these concentrations are double the concentrations measured at home. Two thirds of the trips are car trips, and those trips showed a large spread in concentrations. In-car concentrations are higher during peak hours compared to off-peak, and are elevated on weekdays compared to Saturdays and even more so on Sundays. These findings result in significantly higher exposure during car commute trips (motive 'Work'), and lower concentrations for trips with motive 'Social and leisure'. Because of the many factors influencing exposure in transport, travel time is not a good predictor of integrated personal exposure or inhaled dose.

  5. Simulations of exercise and brain effects of acute exposure to carbon monoxide in normal and vascular-diseased persons.

    EPA Science Inventory

    At some level, carboxyhemoglobin (RbCO) due to inhalation of carbon monoxide (CO) reduces maximum exercise duration in normal and ischemic heart patients. At high RbCO levels in normal subjects, brain function is also affected and behavioral performance is impaired. These are fin...

  6. 49 CFR 176.710 - Care following leakage or sifting of radioactive materials.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... segregated from unnecessary contact with personnel. In case of obvious leakage, or if the inside container appears to be damaged, the stowage area (hold, compartment, or deck area) containing this cargo must be... contact, inhalation, or ingestion. No person may handle the material or remain in the vicinity unless...

  7. Achieving Symptom Control in Patients with Moderate Asthma

    PubMed Central

    Weir, Nargues A.; Levine, Stewart J.

    2012-01-01

    Disease severity in asthma can be classified as mild, moderate or severe based upon the frequency of symptoms or the severity of airflow obstruction. This review will focus on the treatment of youths greater than 12 years of age and adults with moderate persistent asthma. Moderate asthmatics may have daily symptoms that cause some limitation with normal daily activities and require use of a rescue inhaled short-acting beta2-agonist inhaler or experience nocturnal awakenings secondary to asthma that occur more than once per week. Furthermore, spirometry may reveal airflow obstruction with a reduction in FEV1 to between 60% and 80% of predicted. Although inhaled corticosteroids (ICS) are the primary controller medication used to modify symptoms in moderate asthmatics, additional controller medications, such as inhaled long-acting beta2-agonists (LABA), leukotriene receptor antagonists (LTRA) or theophylline, are often needed to obtain optimal disease control. While the addition of an inhaled LABA to an ICS is very effective at improving disease control in moderate asthma, concerns have arisen over the safety of LABAs, in particular the risk of asthma-related death. Therefore, consideration may be given to initially adding a LTRA, rather than a LABA, to ICS when asthma symptoms are not adequately controlled by ICS alone. Furthermore, individualization of medication regimens, treatment of co-morbid conditions, and patient education are crucial to optimizing compliance with therapy, improving disease control, and reducing the risk of exacerbations. Lastly, the development of new asthma treatments, perhaps based upon personalized medicine, may revolutionize the future treatment of moderate asthma. PMID:22259262

  8. Occurrence of Staphylococcus aureus in swine and swine workplace environments on industrial and antibiotic-free hog operations in North Carolina, USA: A One Health pilot study.

    PubMed

    Davis, Meghan F; Pisanic, Nora; Rhodes, Sarah M; Brown, Alexis; Keller, Haley; Nadimpalli, Maya; Christ, Andrea; Ludwig, Shanna; Ordak, Carly; Spicer, Kristoffer; Love, David C; Larsen, Jesper; Wright, Asher; Blacklin, Sarah; Flowers, Billy; Stewart, Jill; Sexton, Kenneth G; Rule, Ana M; Heaney, Christopher D

    2018-05-01

    Occupational exposure to swine has been associated with increased Staphylococcus aureus carriage, including antimicrobial-resistant strains, and increased risk of infections. To characterize animal and environmental routes of worker exposure, we optimized methods to identify S. aureus on operations that raise swine in confinement with antibiotics (industrial hog operation: IHO) versus on pasture without antibiotics (antibiotic-free hog operation: AFHO). We associated findings from tested swine and environmental samples with those from personal inhalable air samplers on worker surrogates at one IHO and three AFHOs in North Carolina using a new One Health approach. We determined swine S. aureus carriage status by collecting swab samples from multiple anatomical sites, and we determined environmental positivity for airborne bioaerosols with inhalable and impinger samplers and a single-stage impactor (ambient air) cross-sectionally. All samples were analyzed for S. aureus, and isolates were tested for antimicrobial susceptibility, absence of scn (livestock marker), and spa type. Seventeen of twenty (85%) swine sampled at the one IHO carried S. aureus at >1 anatomical sites compared to none of 30 (0%) swine sampled at the three AFHOs. All S. aureus isolates recovered from IHO swine and air samples were scn negative and spa type t337; almost all isolates (62/63) were multidrug resistant. S. aureus was recovered from eight of 14 (67%) ambient air and two (100%) worker surrogate personal air samples at the one IHO, whereas no S. aureus isolates were recovered from 19 ambient and six personal air samples at the three AFHOs. Personal worker surrogate inhalable sample findings were consistent with both swine and ambient air data, indicating the potential for workplace exposure. IHO swine and the one IHO environment could be a source of potential pathogen exposure to workers, as supported by the detection of multidrug-resistant S. aureus (MDRSA) with livestock-associated spa type t337 among swine, worker surrogate personal air samplers and environmental air samples at the one IHO but none of the three AFHOs sampled in this study. Concurrent sampling of swine, personal swine worker surrogate air, and ambient airborne dust demonstrated that IHO workers may be exposed through both direct (animal contact) and indirect (airborne) routes of transmission. Investigation of the effectiveness of contact and respiratory protections is warranted to prevent IHO worker exposure to multidrug-resistant livestock-associated S. aureus and other pathogens. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. How preschoolers and adults represent their joint action partner's behavior.

    PubMed

    Sacheli, Lucia Maria; Meyer, M; Hartstra, E; Bekkering, H; Hunnius, S

    2017-10-24

    We investigated the cognitive mechanisms underlying turn-taking joint action in 42-month-old children (Experiment 1) and adults (Experiment 2) using a behavioral task of dressing a virtual bear together. We aimed to investigate how participants represent a partners' behavior, i.e., in terms of specific action kinematics or of action effects. The bear was dressed by pressing a smaller and a bigger button. In the Action-response task, instructions asked participants to respond to the partner by pressing the same or opposite button; in the Action-effect task they had to respond to the partner's action effect by dressing the bear with the lacking part of the clothing, which in some cases implied pressing the same button and in other cases implied pressing the opposite button. In 50% of the trials, the partner's association between each button and the ensuing effect (dressing the bear with t-shirt or pants) was reversed, while it never changed for participants. Both children and adults showed no effect of physical congruency of actions, but showed impaired performance in the Action-effect task if their partner achieved her effect through a different action-effect association than their own. These results suggest that, when encoding their partner's actions, agents are influenced by action-effect associations that they learnt through their own experience. While interference led to overt errors in children, it caused longer reaction times in adults, suggesting that a flexible cognitive control (that is still in development in young children) is required to take on the partner's perspective.

  10. Automatic food detection in egocentric images using artificial intelligence technology.

    PubMed

    Jia, Wenyan; Li, Yuecheng; Qu, Ruowei; Baranowski, Thomas; Burke, Lora E; Zhang, Hong; Bai, Yicheng; Mancino, Juliet M; Xu, Guizhi; Mao, Zhi-Hong; Sun, Mingui

    2018-03-26

    To develop an artificial intelligence (AI)-based algorithm which can automatically detect food items from images acquired by an egocentric wearable camera for dietary assessment. To study human diet and lifestyle, large sets of egocentric images were acquired using a wearable device, called eButton, from free-living individuals. Three thousand nine hundred images containing real-world activities, which formed eButton data set 1, were manually selected from thirty subjects. eButton data set 2 contained 29 515 images acquired from a research participant in a week-long unrestricted recording. They included both food- and non-food-related real-life activities, such as dining at both home and restaurants, cooking, shopping, gardening, housekeeping chores, taking classes, gym exercise, etc. All images in these data sets were classified as food/non-food images based on their tags generated by a convolutional neural network. A cross data-set test was conducted on eButton data set 1. The overall accuracy of food detection was 91·5 and 86·4 %, respectively, when one-half of data set 1 was used for training and the other half for testing. For eButton data set 2, 74·0 % sensitivity and 87·0 % specificity were obtained if both 'food' and 'drink' were considered as food images. Alternatively, if only 'food' items were considered, the sensitivity and specificity reached 85·0 and 85·8 %, respectively. The AI technology can automatically detect foods from low-quality, wearable camera-acquired real-world egocentric images with reasonable accuracy, reducing both the burden of data processing and privacy concerns.

  11. Suture Button Fixation Treatment of Chronic Lisfranc Injury in Professional Dancers and High-Level Athletes.

    PubMed

    Charlton, Timothy; Boe, Chelsea; Thordarson, David B

    2015-12-01

    Chronic Lisfranc injury is a subtle and severe injury in high-level athletes, including dancers. This patient population is generally intolerant of intra-articular screw fixation and can develop significant post-traumatic arthritis with potentially career ending complications. Flexible fixation with suture-button devices provides potential restoration of physiologic motion at the joint, with appropriate support for healing that may facilitate return to en pointe activities for dancers. We hypothesized that the suture-button device would restore motion at the Lisfranc joint and allow for return to activities in this particular population without the limitations and complications of rigid fixation. We operated on seven dancers and high-level athletes with diagnosed Lisfranc injuries by installing a suture-button device. All patients had failed conservative management after late presentation. They were allowed to return to sport in 6 months, preoperative and postoperative American Orthopaedic Foot and Ankle Score (AOFAS) foot scores were obtained, and patients were followed for a minimum of 15 months. All seven returned to full activities in 6 months, with radiographic evidence of fixation and no complications to date. AOFAS foot scores improved from an average of 65 preoperatively to an average of 97 postoperatively at latest follow-up. It is concluded that flexible fixation with suture-button type device represents a viable alternative to screw fixation or fusion that may allow dancers and athletes to return to previous levels of activity after Lisfranc injury. This case series represents to our knowledge the first application of this device to a unique population that requires flexibility at the Lisfranc joint for performance.

  12. Self-Organization of Temporal Structures — A Possible Solution for the Intervention Problem

    NASA Astrophysics Data System (ADS)

    von Lucadou, Walter

    2006-10-01

    The paper presents an experiment that is a conceptual replication of two earlier experiments which demonstrate entanglement correlations between a quantum physical random process and certain psychological variables of human observers. In the present study button-pushes were used as psychological variables. The button-pushes were performed by the subject with his or her left or right hand in order to "control" (according to the instruction) a random process that could be observed on a display. Each button-push started the next random event which, however, in reality, was independent of the button-pushes. The study consists of three independent sets of data (n = 386) that were gained with almost fee same apparatus in three different experimental situations. The first data set serves as reference. It was an automatic control-run without subjects. The second set was produced mainly by subjects who asked for taking part in a para-psychological experiment and who visited the "Parapsychological Counseling Office" in Freiburg especially for this purpose. Most of them were highly motivated persons who wanted to test their "psi ability". In this case the number of runs could be selected by the subjects before the experimental session. The third set of data (of the same size) was collected during two public exhibitions (at Basel and at Freiburg) where the visitors had the opportunity to participate in a "PK experiment". In this case the number of trials and runs was fixed in advance, but the duration of the experiment was dependent of the speed of button-pushes. The results corroborate the previous studies. The specific way how the subjects pushed the buttons is highly significantly correlated with the independent random process. This correlation shows up for the momentarily generated random events as well as for the previous and the later runs during the experimental session. In a strict sense, only the correlations with the future random events can be interpreted as non-local correlations. The structure of the data, however, allows the conclusion, that all observed correlations can be considered as entanglement-correlations. The number of entanglement-correlations was significantly higher for the highly motivated group (data set 2) than for the unselected group of the exhibition participants (data set 3). The latter, however, where not completely unsuccessful: A subgroup who showed "innovative" behavior also showed significant entanglement-correlations. It could further be shown, that the structure of the matrix of entanglement-correlations is not stable in time and changes if the experiment is repeated. In comparison with previous correlation-experiments, no decline of the effect size was observed. These results are in agreement with the predictions of the "Weak Quantum Theory (WQT)" and the "Model of Pragmatic Information (MPI)". These models interpret the measured correlations as entanglement-correlations within a self-organizing, organizationally closed, psycho-physical system that exist during a certain time-interval (as long as the system is active). The entanglement-correlations cannot be considered as a causal influence (in the sense of a PK-Influence) and thus are called "micro-synchronicity". After a short introduction (1.), the question is discussed how non-local correlations can be created in psycho-physical systems (2.). In chapter (3.) the description of the experimental setting is given and the apparatus (4.) and randomness test of the random event generator (5.) are described. Additionally, an overview of the structure of the data is given (6.) and the analysis methods are described (7.). In chapter (8.) the experimental hypotheses are formulated and the results are reported (9.). After the discussion of the results (10.) the conclusions (11).) of the study are presented.

  13. Spicing Things up by Adding Color and Relieving Pain: The Use of "Napoleon's Buttons" in Organic Chemistry

    ERIC Educational Resources Information Center

    Bucholtz, Kevin M.

    2011-01-01

    For some students, organic chemistry can be a distant subject and unrelated to any courses they have seen in their college careers. To develop a more contextual learning experience in organic chemistry, an additional text, "Napoleon's Buttons: 17 Molecules That Changed History," by Penny Le Couteur and Jay Burreson, was incorporated as a…

  14. Miniature Two-Axis Joystick Controller

    NASA Technical Reports Server (NTRS)

    Hollow, R.

    1983-01-01

    Novel movable-button-actuated self-centering controller uses optoelectronics to produce X and Y signals for aircraft control. In addition to be extremely compact, device puts our voltages having high signal-to-noise ratio, especially at critical center position where in many controllers this ratio is poorest. Combination of new saddle-shaped button and positive centering gives "feel" and "breakout" met with pilot approval.

  15. --No Title--

    Science.gov Websites

    :#ccc;text-align:center;padding:5px}.upper_button{text-align:right;padding-bottom:5px}.side_button[type ;width:175px;text-align:left;font-weight:bold;overflow:hidden}.left_head_title_alt{float:left;width:175px ;text-align:left;font-weight:bold;line-height:16px;margin-top:3px;padding-top:0}.left_head_add

  16. Genome sequence of the button mushroom Agaricus bisporus reveals mechanisms governing adaptation to a humic-rich ecological niche

    Treesearch

    Emmanuelle Morin; Annegret Kohler; Adam R. Baker; Marie Foulongne-Oriol; Vincent Lombard; Laszlo G. Nagy; Robin A. Ohm; Aleksandrina Patyshakuliyeva; Annick Brun; Andrea L. Aerts; Andrew M. Bailey; Christophe Billette; Pedro M. Coutinho; Greg Deakin; Harshavardhan Doddapaneni; Dimitrios Floudas; Jane Grimwood; Kristiina Hild& #233; n; Ursula K& #252; es; Kurt M. LaButti; Alla Lapidus; Erika A. Lindquist; Susan M. Lucas; Claude Murat; Robert W. Riley; Asaf A. Salamov; Jeremy Schmutz; Venkataramanan Subrananian; Han A.B. W& #246; sten; Jianping Xu; Daniel C. Eastwood; Gary D. Foster; Anton S.M. Sonnenberg; Daniel Cullen; Ronald P. de Vries; Taina Lundell; David S. Hibbett; Bernard Henrissat; Kerry S. Burton; Richard W. Kerrigan; Michael P. Challen; Igor V. Grigoriev; Francis Martin

    2012-01-01

    Agaricus bisporus is the model fungus for the adaptation, persistence,and growth in the humic-rich leaf-litter environment. Aside from its ecological role, A. bisporus has been an important component of the human diet for over 200 y and worldwide cultivation of the "button mushroom" forms a multibillion dollar...

  17. Don't wear that button out!

    NASA Astrophysics Data System (ADS)

    Jue, Brian J.; Bice, Michael D.

    2013-07-01

    As students explore the technological tools available to them for learning mathematics, some will eventually discover what happens when a function button is repeatedly pressed on a calculator. We explore several examples of this, presenting tabular and graphical results for the square root, natural logarithm and sine and cosine functions. Observed behaviour is proven and then discussed in the context of fixed points.

  18. A burr hole button to secure the electrode cable in depth electrode placement. Technical note.

    PubMed

    Kamiryo, T; Laws, E R

    1997-05-01

    A simple magnetic resonance imaging-compatible buttonlike device was devised to fix a depth electrode cable securely in the burr hole used for its insertion during surgery for depth electrode placement. The button is tightly fixed in the burr hole and it holds the cable without allowing protrusion or tension on the wound.

  19. Using Buttons to Better Manage Online Presence: How One Academic Institution Harnessed the Power of Flair

    ERIC Educational Resources Information Center

    Dority Baker, Marcia L.

    2013-01-01

    This article provides a case study of how the University of Nebraska College of Law and Schmid Law Library use "buttons" to manage Law College faculty members' and librarians' online presence. Since Google is the primary search engine used to find information, it is important that librarians and libraries assist Web site visitors in…

  20. --No Title--

    Science.gov Websites

    fixme{background-color:#ff0}.container-fluid{padding:0;margin:0}.hp{font-family:Roboto," }.hp-hero-text{position:absolute;text-shadow:1px 1px 1px rgba(150,150,150,1)}.hp-hero h2{color:#fff}.hp -hero button{color:#e3e3e3;font-size:10px;background:transparent;border:none}.hp-hero button:hover,.hp

  1. Stimulus-dependent deliberation process leading to a specific motor action demonstrated via a multi-channel EEG analysis

    PubMed Central

    Henz, Sonja; Kutz, Dieter F.; Werner, Jana; Hürster, Walter; Kolb, Florian P.; Nida-Ruemelin, Julian

    2015-01-01

    The aim of the study was to determine whether a deliberative process, leading to a motor action, is detectable in high density EEG recordings. Subjects were required to press one of two buttons. In a simple motor task the subject knew which button to press, whilst in a color-word Stroop task subjects had to press the right button with the right index finger when meaning and color coincided, or the left button with the left index finger when meaning and color were disparate. EEG recordings obtained during the simple motor task showed a sequence of positive (P) and negative (N) cortical potentials (P1-N1-P2) which are assumed to be related to the processing of the movement. The sequence of cortical potentials was similar in EEG recordings of subjects having to deliberate over how to respond, but the above sequence (P1-N1-P2) was preceded by slowly increasing negativity (N0), with N0 being assumed to represent the end of the deliberation process. Our data suggest the existence of neurophysiological correlates of deliberative processes. PMID:26190987

  2. Repair of Double Head Pectoralis Major Tendon Avulsion into its Native Footprint Using Bi-cortical EndoButtons and Tendon Sliding Technique.

    PubMed

    Prabhu, Jagadish; Faqi, Mohammed Khalid; Alkhalifa, Fahad; Tayara, Bader Kamal; Awad, Rashad Khamis

    2017-01-01

    Injuries to the pectoralis major muscle are relatively infrequent. The mechanism of injury is usually an eccentric shortening of the pectoralis major under heavy load, such as when performing a bench press exercise. We report a case that presented to us with a history of sudden pain in the left pectoral region while doing heavy bench press exercise. The patient sustained a type III D pectoralis muscle -tendon avulsion. Surgical repair was done through a bi-cortical tendon sliding technique using two cortical buttons. In this article we describe our modifications to the previously described surgical technique for the pectoralis major tendon repair using the EndoButton and tension - slide technique, aiming to overcome the possible complications.

  3. Fixation of unstable type II clavicle fractures with distal clavicle plate and suture button.

    PubMed

    Johnston, Peter S; Sears, Benjamin W; Lazarus, Mark R; Frieman, Barbara G

    2014-11-01

    This article reports on a technique to treat unstable type II distal clavicle fractures using fracture-specific plates and coracoclavicular augmentation with a suture button. Six patients with clinically unstable type II distal clavicle fractures underwent treatment using the above technique. All fractures demonstrated radiographic union at 9.6 (8.4-11.6) weeks with a mean follow-up of 15.6 (12.4-22.3) months. American Shoulder and Elbow Surgeons, Penn Shoulder Score, and Single Assessment Numeric Evaluation scores were 97.97 (98.33-100), 96.4 (91-99), and 95 (90-100), respectively. One patient required implant removal. Fracture-specific plating with suture-button augmentation for type II distal clavicle fractures provides reliable rates of union without absolute requirement for implant removal.

  4. Management of foreign body ingestions in children: button batteries and magnets.

    PubMed

    Kodituwakku, Ronan; Palmer, Sarah; Paul, Siba Prosad

    2017-04-27

    Foreign body ingestion and foreign body aspiration commonly affect young children between 6 months and 6 years. A large number of these events remain unwitnessed and asymptomatic while the swallowed foreign body traverses the gastrointestinal tract and is passed in the stool. Recent literature has shown an increase in morbidity associated with button battery and (neomydium) magnet ingestions in children, particularly over the last decade. Early identification and management in a time critical manner is required in cases where button batteries get lodged in the oesophagus or multiple magnets are swallowed. Deaths, although rare, have been reported with these dangerous foreign body ingestions in children where diagnoses were delayed. Nurses through their direct contact with children in different clinical settings play a vital role in managing foreign body ingestions.

  5. Occupational Exposure to Cobalt and Tungsten in the Swedish Hard Metal Industry: Air Concentrations of Particle Mass, Number, and Surface Area

    PubMed Central

    Bryngelsson, Ing-Liss; Pettersson, Carin; Husby, Bente; Arvidsson, Helena; Westberg, Håkan

    2016-01-01

    Exposure to cobalt in the hard metal industry entails severe adverse health effects, including lung cancer and hard metal fibrosis. The main aim of this study was to determine exposure air concentration levels of cobalt and tungsten for risk assessment and dose–response analysis in our medical investigations in a Swedish hard metal plant. We also present mass-based, particle surface area, and particle number air concentrations from stationary sampling and investigate the possibility of using these data as proxies for exposure measures in our study. Personal exposure full-shift measurements were performed for inhalable and total dust, cobalt, and tungsten, including personal real-time continuous monitoring of dust. Stationary measurements of inhalable and total dust, PM2.5, and PM10 was also performed and cobalt and tungsten levels were determined, as were air concentration of particle number and particle surface area of fine particles. The personal exposure levels of inhalable dust were consistently low (AM 0.15mg m−3, range <0.023–3.0mg m−3) and below the present Swedish occupational exposure limit (OEL) of 10mg m−3. The cobalt levels were low as well (AM 0.0030mg m−3, range 0.000028–0.056mg m−3) and only 6% of the samples exceeded the Swedish OEL of 0.02mg m−3. For continuous personal monitoring of dust exposure, the peaks ranged from 0.001 to 83mg m−3 by work task. Stationary measurements showed lower average levels both for inhalable and total dust and cobalt. The particle number concentration of fine particles (AM 3000 p·cm−3) showed the highest levels at the departments of powder production, pressing and storage, and for the particle surface area concentrations (AM 7.6 µm2·cm−3) similar results were found. Correlating cobalt mass-based exposure measurements to cobalt stationary mass-based, particle area, and particle number concentrations by rank and department showed significant correlations for all measures except for particle number. Linear regression analysis of the same data showed statistically significant regression coefficients only for the mass-based aerosol measures. Similar results were seen for rank correlation in the stationary rig, and linear regression analysis implied significant correlation for mass-based and particle surface area measures. The mass-based air concentration levels of cobalt and tungsten in the hard metal plant in our study were low compared to Swedish OELs. Particle number and particle surface area concentrations were in the same order of magnitude as for other industrial settings. Regression analysis implied the use of stationary determined mass-based and particle surface area aerosol concentration as proxies for various exposure measures in our study. PMID:27143598

  6. Personal graphical communicator.

    PubMed

    Stephens, Michael; Barrett, Steven

    2008-01-01

    A device to help a child communicate was requested by an educator. The child cannot read, write, or speak but can recognize symbols and use those symbols to communicate. While this communication works, it doesn't work well in situations where another person does not know how to use the symbols to communicate. For this reason, a device was requested that could display images to a child and play a phrase when that image was chosen. To meet this need an MP3 player like device was constructed. The device stores images and Mpeg-Layer III (MP3) sound clips on a replaceable Secure Digital (SD) card. The images are displayed on a color Liquid Crystal Display (LCD) where the user is able to skip through images to find the phrase that needs to be said. Once found simply hitting the play button will play the sound clip associated with the image. The device is portable and compact for easy use. It uses Universal Serial Bus (USB) to recharge its batteries, communicate with the PC and update the firmware.

  7. Assessment of health effects in epidemiologic studies of air pollution.

    PubMed Central

    Samet, J M; Speizer, F E

    1993-01-01

    As we increasingly recognize the complexity of the pollutants in indoor and outdoor microenvironments, a broad array of inhaled mixtures has assumed scientific, public health, and regulatory importance. Few adverse effects of environmental pollutants are specific, that is, uniquely associated with a single agent; the adverse effects that might be considered in an investigation of the consequences of exposure to an inhaled complex mixture are generally nonspecific. In the context of this paper, we will refer to binary mixtures as complex, though we realize that a more precise definition of complexity would restrict the term to mixtures of three or more constituents. Their causes potentially include not only pollutant exposures through the medium of inhaled air but other environmental agents, such as infectious organisms and radiation, and inherent characteristics of the exposed persons, such as atopy. We review the outcome measures that have been used in epidemiologic studies of the health effects of single pollutants and complex mixtures. Some of these outcome measures have been carefully standardized, whereas others need similar standardization and modification to improve sensitivity and specificity for investigating the health effects of air pollution. PMID:8206024

  8. An ontology-based nurse call management system (oNCS) with probabilistic priority assessment

    PubMed Central

    2011-01-01

    Background The current, place-oriented nurse call systems are very static. A patient can only make calls with a button which is fixed to a wall of a room. Moreover, the system does not take into account various factors specific to a situation. In the future, there will be an evolution to a mobile button for each patient so that they can walk around freely and still make calls. The system would become person-oriented and the available context information should be taken into account to assign the correct nurse to a call. The aim of this research is (1) the design of a software platform that supports the transition to mobile and wireless nurse call buttons in hospitals and residential care and (2) the design of a sophisticated nurse call algorithm. This algorithm dynamically adapts to the situation at hand by taking the profile information of staff members and patients into account. Additionally, the priority of a call probabilistically depends on the risk factors, assigned to a patient. Methods The ontology-based Nurse Call System (oNCS) was developed as an extension of a Context-Aware Service Platform. An ontology is used to manage the profile information. Rules implement the novel nurse call algorithm that takes all this information into account. Probabilistic reasoning algorithms are designed to determine the priority of a call based on the risk factors of the patient. Results The oNCS system is evaluated through a prototype implementation and simulations, based on a detailed dataset obtained from Ghent University Hospital. The arrival times of nurses at the location of a call, the workload distribution of calls amongst nurses and the assignment of priorities to calls are compared for the oNCS system and the current, place-oriented nurse call system. Additionally, the performance of the system is discussed. Conclusions The execution time of the nurse call algorithm is on average 50.333 ms. Moreover, the oNCS system significantly improves the assignment of nurses to calls. Calls generally have a nurse present faster and the workload-distribution amongst the nurses improves. PMID:21294860

  9. Aromatherapy for stress reduction in healthy adults: a systematic review and meta-analysis of randomized clinical trials.

    PubMed

    Hur, Myung-Haeng; Song, Ji-Ah; Lee, Jeonghee; Lee, Myeong Soo

    2014-12-01

    The aim of this review was to systematically assess the effectiveness of aromatherapy for stress management. Seven databases were searched from their inception through April 2014. RCTs testing aromatherapy against any type of controls in healthy human person that assessed stress level and cortisol level were considered. Two reviewers independently performed the selection of the studies, data abstraction and validations. The risk of bias was assessed using Cochrane criteria. Five RCTs met our inclusion criteria, and most of them had high risk of bias. Four RCTs tested the effects of aroma inhalation compared with no treatment, no aroma, and no odour oil. The meta-analysis suggested that aroma inhalation has favourable effects on stress management (n=80; standard mean difference (SMD), -0.96; 95% CI, -1.44 to -0.48; P<0.0001; I(2)=0%). Three of included RCTs tested aroma inhalation on saliva or serum cortisol level compared with control and meta-analysis failed to show significant difference between two groups (n=88, SMDs -0.62; 95% CIs -1.26 to 0.02, P=0.06, I(2)=46%). In conclusion, there is limited evidence suggesting that aroma inhalation may be effective in controlling stress. However, the number, size and quality of the RCTs are too low to draw firm conclusions. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  10. The impact of community pharmacy-led medicines management support for people with COPD.

    PubMed

    Alton, Sarah; Farndon, Lisa

    2018-06-02

    Chronic obstructive pulmonary disease (COPD) is a common long-term condition involving restricted airflow, which reduces quality of life. Treatments include lifestyle changes (smoking cessation), pulmonary rehabilitation and medication with inhaled therapies. However, medication adherence is often suboptimal, resulting in poor health outcomes. A pilot project assessed the impact of medicines management support from a community pharmacy team for people with COPD, delivered in their own homes. Individuals were given a medication review and an assessment of their inhaler technique and were followed up at 3 and 6 months. The COPD Assessment Test (CAT) score was administered before and after the intervention. A change in score of 2 or more suggests a significant difference; the average score was 19.2 at the first assessment and 16.7 at the six month follow-up. Seventeen patients had improved CAT scores, 10 patients had a reduced score and three remained unchanged. Most patients evaluated the project positively as it helped them to improve their inhaler technique. Medicines optimisation was also achieved as a person-centred approach was taken; suboptimal practice had not been picked up by health professionals previously. Community pharmacists working in integrated care teams provide invaluable support to patients with COPD. This project will be rolled out across the community team, and training on medicines management and inhaler technique provided to other health professionals involved in the care of these patients.

  11. Effect of dietary supplementation with white button mushrooms on host resistance to influenza infection and immune function in mice

    USDA-ARS?s Scientific Manuscript database

    Previously we showed that mice fed white button mushrooms (WBM) had enhanced immune functions known to help the body’s antiviral defense. In this study, we tested if WBM could afford protection against viral infection. Young (4-mo) and old (22-mo) C57BL/6 mice were fed a diet containing 0, 2 per cen...

  12. Type of Primary Nb₅Si₃ and Precipitation of Nbss in αNb₅Si₃ in a Nb-8.3Ti-21.1Si-5.4Mo-4W-0.7Hf (at.%) Near Eutectic Nb-Silicide-Based Alloy.

    PubMed

    McCaughey, Conor; Tsakiropoulos, Panos

    2018-06-07

    The Nb-silicide-based alloy of near eutectic composition (at.%) Nb-21.1Si-8.3Ti-5.4Mo-4W-0.7Hf (alloy CM1) was studied in the cast and heat-treated (1500 °C/100 h) conditions. The alloy was produced in the form of buttons and bars using three different methods, namely arc-melting, arc-melting and suction casting, and optical floating zone (OFZ) melting. In the former two cases the alloy solidified in water-cooled copper crucibles. Buttons and suction-cast bars of different size, respectively of 10 g and 600 g weight and 6 mm and 8 mm diameter, were produced. The OFZ bars were grown at three different growth rates of 12, 60 and 150 mm/h. It was confirmed that the type of Nb₅Si₃ formed in the cast microstructures depended on the solidification conditions. The primary phase in the alloy CM1 was the βNb₅Si₃. The transformation of βNb₅Si₃ to αNb₅Si₃ had occurred in the as cast large size button and the OFZ bars grown at the three different growth rates, and after the heat treatment of the small size button and the suction-cast bars of the alloy. This transformation was accompanied by subgrain formation in Nb₅Si₃ and the precipitation of Nb ss in the large size as cast button and only by the precipitation of Nb ss in the cast OFZ bars. Subgrains and precipitation of Nb ss in αNb₅Si₃ was observed in the small size button and suction-cast bars after the heat treatment. Subgrains formed in αNb₅Si₃ after the heat treatment of the OFZ bars. The partitioning of solutes and in particular of Mo and Ti was key to this phase transformation. Subgrain formation was not necessary for precipitation of Nb ss in αNb₅Si₃, but the partitioning of solutes was essential for this precipitation.

  13. Quadrupling Inhaled Glucocorticoid Dose to Abort Asthma Exacerbations.

    PubMed

    McKeever, Tricia; Mortimer, Kevin; Wilson, Andrew; Walker, Samantha; Brightling, Christopher; Skeggs, Andrew; Pavord, Ian; Price, David; Duley, Lelia; Thomas, Mike; Bradshaw, Lucy; Higgins, Bernard; Haydock, Rebecca; Mitchell, Eleanor; Devereux, Graham; Harrison, Timothy

    2018-03-08

    Asthma exacerbations are frightening for patients and are occasionally fatal. We tested the concept that a plan for patients to manage their asthma (self-management plan), which included a temporary quadrupling of the dose of inhaled glucocorticoids when asthma control started to deteriorate, would reduce the incidence of severe asthma exacerbations among adults and adolescents with asthma. We conducted a pragmatic, unblinded, randomized trial involving adults and adolescents with asthma who were receiving inhaled glucocorticoids, with or without add-on therapy, and who had had at least one exacerbation in the previous 12 months. We compared a self-management plan that included an increase in the dose of inhaled glucocorticoids by a factor of 4 (quadrupling group) with the same plan without such an increase (non-quadrupling group), over a period of 12 months. The primary outcome was the time to a first severe asthma exacerbation, defined as treatment with systemic glucocorticoids or an unscheduled health care consultation for asthma. A total of 1922 participants underwent randomization, of whom 1871 were included in the primary analysis. The number of participants who had a severe asthma exacerbation in the year after randomization was 420 (45%) in the quadrupling group as compared with 484 (52%) in the non-quadrupling group, with an adjusted hazard ratio for the time to a first severe exacerbation of 0.81 (95% confidence interval, 0.71 to 0.92; P=0.002). The rate of adverse effects, which were related primarily to local effects of inhaled glucocorticoids, was higher in the quadrupling group than in the non-quadrupling group. In this trial involving adults and adolescents with asthma, a personalized self-management plan that included a temporary quadrupling of the dose of inhaled glucocorticoids when asthma control started to deteriorate resulted in fewer severe asthma exacerbations than a plan in which the dose was not increased. (Funded by the Health Technology Assessment Programme of the National Institute for Health Research; Current Controlled Trials number, ISRCTN15441965 .).

  14. Patients' reasons for accepting a free community pharmacy asthma service.

    PubMed

    Kaae, Susanne; Sporrong, Sofia Kälvemark

    2015-10-01

    Challenges in recruiting patients at the pharmacy counter for cognitive services have been observed, hampering development in this area. To overcome this barrier, insight into the patient perspective is crucial to understanding their lack of appreciation of the services. However, very few studies have been conducted so far to explore why patients accept or decline offers of cognitive services at the pharmacy counter. To explore patients' reasons for accepting a particular cognitive service (the Inhaler Technique Assessment Service) a service intended to detect inhalation technique errors. The service is reimbursed by the Danish state and takes approximately 10 min. Setting Ten community pharmacies located in different regions of Denmark, including the center and suburbs of Copenhagen. Two types of interviews were conducted: long and short semi-structured interviews with 24 patients suffering mainly from asthma and COPD. Researchers from Copenhagen University conducted 11 long interviews and pharmacy internship students from Copenhagen University carried out 13 short interviews. The interviews were analyzed using descriptive analysis. Patients' perceived needs of an inhalation counseling service as well as their motivation for accepting the service, including their accounts of how the service was orally offered by staff. The majority of participants were used to using inhaler devices. The participants felt, for several reasons, little need of an inhaler service and seldom noticed the precise way the service was offered. Patients did not seem to accept the service expecting personal benefits. First timers appeared to accept the service to learn how to use the device correctly, whereas experienced users appeared to accept the ITAS to be helpful to staff or to learn more about health issues in general or were convinced by individual employees who showed a special interest in the participant receiving the service. Privacy problems were felt by several participants. The patients felt little need for the inhaler counseling service. Patients however accepted the service for various reasons of which the feeling how staff showing an interest in helping them seemed especially convincing.

  15. Biomechanics of the Proximal Radius Following Drilling of the Bicipital Tuberosity to Mimic Cortical Button Distal Biceps Repair Technique.

    PubMed

    Oak, Nikhil R; Lien, John R; Brunfeldt, Alexander; Lawton, Jeffrey N

    2018-05-01

    A fracture through the proximal radius is a theoretical concern after cortical button distal biceps fixation in an active patient. The permanent, nonossified cortical defect and medullary tunnel is at risk during a fall eliciting rotational and compressive forces. We hypothesized that during simulated torsion and compression, in comparison with unaltered specimens, the cortical button distal biceps repair model would have decreased torsional and compressive strength and would fracture in the vicinity of the bicipital tuberosity bone tunnel. Sixteen fourth-generation composite radius Sawbones models were used in this controlled laboratory study. A bone tunnel was created through the bicipital tuberosity to mimic the exact bone tunnel, 8 mm near cortex and 3.2 mm far cortex, made for the BicepsButton distal biceps tendon repair. The radius was then prepared and mounted on either a torsional or compression testing device and compared with undrilled control specimens. Compression tests resulted in average failure loads of 9015.2 N in controls versus 8253.25 N in drilled specimens ( P = .074). Torsional testing resulted in an average failure torque of 27.3 Nm in controls and 19.3 Nm in drilled specimens ( P = .024). Average fracture angle was 35.1° in controls versus 21.1° in drilled. Gross fracture patterns were similar in compression testing; however, in torsional testing all fractures occurred through the bone tunnel in the drilled group. There are weaknesses in the vicinity of the bone tunnel in the proximal radius during biomechanical stress testing which may not be clinically relevant in nature. In cortical button fixation, distal biceps repairs creates a permanent, nonossified cortical defect with tendon interposed in the bone tunnel, which can alter the biomechanical properties of the proximal radius during compressive and torsional loading.

  16. Anterior capsulotomy with an ultrashort-pulse laser.

    PubMed

    Tackman, Ramon Naranjo; Kuri, Jorge Villar; Nichamin, Louis D Skip; Edwards, Keith

    2011-05-01

    To assess the precision of laser anterior capsulotomy compared with that of manual continuous curvilinear capsulorhexis (CCC). Asociación Para Evitar La Ceguera en México IAP, Hospital Dr. Luis Sánchez Bulnes, Mexico City, Mexico. Nonrandomized single-center clinical trial. In patients presenting for cataract surgery, the LensAR Laser System was used to create a laser anterior capsulotomy of the surgeon's desired size. Capsule buttons were retrieved and measured and then compared with buttons retrieved from eyes having a manually torn CCC. Deviation from the intended diameter and the regularity of shape were assessed. When removing the capsule buttons at the start of surgery, the surgeon rated the ease of removal on a scale of 1 to 10 (1 = required manual capsulorhexis around the whole diameter; 10 = button free floating or required no manual detachment from remaining capsule during removal). The mean deviation from the intended diameter was 0.16 mm ± 0.17 (SD) for laser anterior capsulotomy and 0.42 ± 0.54 mm for CCC (P=.03). The mean absolute deviation from the intended diameter was 0.20 ± 0.12 mm and 0.49 ± 0.47 mm, respectively (P=.003). The mean of the average squared residuals was 0.01 ± 0.03 and 0.02 ± 0.04, respectively (P=.09). The median rating of the ease of removal was 9 (range 5 to 10). Laser anterior capsulotomy created a more precise capsule opening than CCC, and the buttons created by the laser procedure were easy to remove at the beginning of cataract surgery. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  17. A typewriting system operated by head movements, based on home-computer equipment.

    PubMed

    Heuvelmans, A M; Mélotte, H E; Neve, J J

    1990-06-01

    For persons who cannot move their hands and legs we have designed a relatively inexpensive typewriting system which can be operated by movements of the head. The typewriter is made up of commercially available home computer equipment - i e, a computer including monitor and printer and a headset replacing the mouse. A user-friendly software program has been designed to replace the mouse button and to make this equipment act as a typewriter with simple text-editing features. Some ergonomics aspects of the typewriter set-up and the results of an evaluation of the typewriter by two patients suffering from amyotrophic lateral sclerosis (ALS) are given. Several factors relevant to the design, construction, evaluation and application of the typewriter are discussed.

  18. Size selective isocyanate aerosols personal air sampling using porous plastic foams

    NASA Astrophysics Data System (ADS)

    Khanh Huynh, Cong; Duc, Trinh Vu

    2009-02-01

    As part of a European project (SMT4-CT96-2137), various European institutions specialized in occupational hygiene (BGIA, HSL, IOM, INRS, IST, Ambiente e Lavoro) have established a program of scientific collaboration to develop one or more prototypes of European personal samplers for the collection of simultaneous three dust fractions: inhalable, thoracic and respirable. These samplers based on existing sampling heads (IOM, GSP and cassettes) use Polyurethane Plastic Foam (PUF) according to their porosity to support sampling and separator size of the particles. In this study, the authors present an original application of size selective personal air sampling using chemical impregnated PUF to perform isocyanate aerosols capturing and derivatizing in industrial spray-painting shops.

  19. Adhesion testing device

    NASA Technical Reports Server (NTRS)

    LaPeyronnie, Glenn M. (Inventor); Huff, Charles M. (Inventor)

    2010-01-01

    The present invention provides a testing apparatus and method for testing the adhesion of a coating to a surface. The invention also includes an improved testing button or dolly for use with the testing apparatus and a self aligning button hook or dolly interface on the testing apparatus. According to preferred forms, the apparatus and method of the present invention are simple, portable, battery operated rugged, and inexpensive to manufacture and use, are readily adaptable to a wide variety of uses, and provide effective and accurate testing results. The device includes a linear actuator driven by an electric motor coupled to the actuator through a gearbox and a rotatable shaft. The electronics for the device are contained in the head section of the device. At the contact end of the device, is positioned a self aligning button hook, attached below the load cell located on the actuator shaft.

  20. Connected cane: Tactile button input for controlling gestures of iOS voiceover embedded in a white cane.

    PubMed

    Batterman, Jared M; Martin, Vincent F; Yeung, Derek; Walker, Bruce N

    2018-01-01

    Accessibility of assistive consumer devices is an emerging research area with potential to benefit both users with and without visual impairments. In this article, we discuss the research and evaluation of using a tactile button interface to control an iOS device's native VoiceOver Gesture navigations (Apple Accessibility, 2014). This research effort identified potential safety and accessibility issues for users trying to interact and control their touchscreen mobile iOS devices while traveling independently. Furthermore, this article discusses the participatory design process in creating a solution that aims to solve issues in utilizing a tactile button interface in a novel device. The overall goal of this study is to enable visually impaired white cane users to access their mobile iOS device's capabilities navigation aids more safely and efficiently on the go.

  1. Factors influencing the reinforcing value of fruit and unhealthy snacks.

    PubMed

    Vervoort, L; Clauwaert, A; Vandeweghe, L; Vangeel, J; Van Lippevelde, W; Goossens, L; Huybregts, L; Lachat, C; Eggermont, S; Beullens, K; Braet, C; De Cock, N

    2017-12-01

    The present study investigated the reinforcing value of healthy and unhealthy snack food in adolescents (n = 108, aged 14-16 years). Moderation by access to different foods, sex and the personality trait reward sensitivity is tested. In a computerized Food Reinforcement Task, adolescents could earn portions of a healthy and an unhealthy snack following an identical progressive reinforcement schedule for both food types. Reinforcing value of food was indexed by the number of button presses for each food type. Participants were allocated randomly to two-order condition: fruit-snack versus snack-fruit. Reward sensitivity was assessed with the Dutch age-downward version of Carver and White's BIS/BAS scale. Results showed that the reinforcing value of an unhealthy snack is higher than that of fruit, with participants making more button presses for unhealthy snacks, M = 1280.40, SD = 1203.53, than for fruit, M = 488.04, SD = 401.45, F(1,48) = 25.37, p < 0.001. This effect is stronger in boys (β = -1367.67) than in girls (β = -548.61). The effect is only present in the snack-fruit condition, not in the fruit-snack condition, indicating that access to food moderates the effect of food type. There is no evidence for moderation by reward sensitivity. Results point to the importance of simultaneously increasing barriers to obtain unhealthy food and promoting access to healthy food in order to facilitate healthy food choices.

  2. Quantitative plasma biomarker analysis in HDI exposure assessment.

    PubMed

    Flack, Sheila L; Fent, Kenneth W; Trelles Gaines, Linda G; Thomasen, Jennifer M; Whittaker, Steve; Ball, Louise M; Nylander-French, Leena A

    2010-01-01

    Quantification of amines in biological samples is important for evaluating occupational exposure to diisocyanates. In this study, we describe the quantification of 1,6-hexamethylene diamine (HDA) levels in hydrolyzed plasma of 46 spray painters applying 1,6-hexamethylene diisocyanate (HDI)-containing paint in vehicle repair shops collected during repeated visits to their workplace and their relationship with dermal and inhalation exposure to HDI monomer. HDA was detected in 76% of plasma samples, as heptafluorobutyryl derivatives, and the range of HDA concentrations was < or =0.02-0.92 microg l(-1). After log-transformation of the data, the correlation between plasma HDA levels and HDI inhalation exposure measured on the same workday was low (N = 108, r = 0.22, P = 0.026) compared with the correlation between plasma HDA levels and inhalation exposure occurring approximately 20 to 60 days before blood collection (N = 29, r = 0.57, P = 0.0014). The correlation between plasma HDA levels and HDI dermal exposure measured on the same workday, although statistically significant, was low (N = 108, r = 0.22, P = 0.040) while the correlation between HDA and dermal exposure occurring approximately 20 to 60 days before blood collection was slightly improved (N = 29, r = 0.36, P = 0.053). We evaluated various workplace factors and controls (i.e. location, personal protective equipment use and paint booth type) as modifiers of plasma HDA levels. Workers using a downdraft-ventilated booth had significantly lower plasma HDA levels relative to semi-downdraft and crossdraft booth types (P = 0.0108); this trend was comparable to HDI inhalation and dermal exposure levels stratified by booth type. These findings indicate that HDA concentration in hydrolyzed plasma may be used as a biomarker of cumulative inhalation and dermal exposure to HDI and for investigating the effectiveness of exposure controls in the workplace.

  3. A survey of size-fractionated dust levels in the U.S. wood processing industry.

    PubMed

    Kalliny, Medhat I; Brisolara, Joseph A; Glindmeyer, Henry; Rando, Roy

    2008-08-01

    A survey of size-fractionated dust exposure was carried out in 10 wood processing plants across the United States as part of a 5-year longitudinal respiratory health study. The facilities included a sawmill, plywood assembly plants, secondary wood milling operations, and factories producing finished wood products such as wood furniture and cabinets. Size-fractionated dust exposures were determined using the RespiCon Personal Particle Sampler. There were 2430 valid sets of respirable, thoracic, and inhalable dust samples collected. Overall, geometric mean (geometric standard deviation) exposure levels were found to be 1.44 (2.67), 0.35 (2.65), and 0.18 (2.54) mg/m, for the inhalable, thoracic, and respirable fractions, respectively. Averaged across all samples, the respirable fraction accounted for 16.7% of the inhalable dust mass, whereas the corresponding figure for thoracic fraction as a percentage of the inhalable fraction was 28.7%. Exposures in the furniture manufacturing plants were significantly higher than those in sawmill and plywood assembly plants, wood milling plants, and cabinet manufacturing plants, whereas the sawmill and plywood assembly plants exhibited significantly lower dust levels than the other industry segments. Among work activities, cleaning with compressed air and sanding processes produced the highest size-fractionated dust exposures, whereas forklift drivers demonstrated the lowest respirable and inhalable dust fractions and shipping processes produced the lowest thoracic dust fraction. Other common work activities such as sawing, milling, and clamping exhibited intermediate exposure levels, but there were significant differences in relative ranking of these across the various industry segments. Processing of hardwood and mixed woods generally were associated with higher exposures than were softwood and plywood, although these results were confounded with industry segment also.

  4. Developing a Virtual Teach-To-Goal™ Inhaler Technique Learning Module: A Mixed Methods Approach.

    PubMed

    Wu, Meng; Woodrick, Nicole M; Arora, Vineet M; Farnan, Jeanne M; Press, Valerie G

    Most hospitalized patients with asthma or chronic obstructive pulmonary disease misuse respiratory inhalers. An in-person educational strategy, teach-to-goal (TTG), improves inpatients' inhaler technique. To develop an effective, portable education intervention that remains accessible to hospitalized patients postdischarge for reinforcement of proper inhaler technique. A mixed methods approach at an urban academic hospital was used to iteratively develop, modify, and test a virtual teach-to-goal ™ (V-TTG ™ ) educational intervention using patient end-user feedback. A survey examined access and willingness to use technology for self-management education. Focus groups evaluated patients' feedback on access, functionality, and quality of V-TTG ™ . Forty-eight participants completed the survey, with most reporting having Internet access; 77% used the Internet at home and 82% used the Internet at least once every few weeks. More than 80% reported that they were somewhat or very likely to use V-TTG ™ to gain skills to improve their health. Most participants reported smartphone access (73%); half owned laptop computers (52%). Participants with asthma versus chronic obstructive pulmonary disease were more likely to own a smartphone, have a data plan, and have daily Internet use (P < .05). Nine focus groups (n = 25) identified themes for each domain: access-platform and delivery, Internet access, and technological literacy; functionality-usefulness, content, and teaching strategy; and quality-clarity, ease of use, length, and likability. V-TTG ™ is a promising educational tool for improving patients' inhaler technique, iteratively developed and refined with patient input. Patients in our urban, academic hospital overwhelmingly reported access to platforms and willingness to use V-TTG ™ for health education. Copyright © 2017 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  5. History of Inuit Community Exposure to Lead, Cadmium, and Mercury in Sewage Lake Sediments

    PubMed Central

    Hermanson, Mark H.; Brozowski, James R.

    2005-01-01

    Exposure to lead, cadmium, and mercury is known to be high in many arctic Inuit communities. These metals are emitted from industrial and urban sources, are distributed by long-range atmospheric transport to remote regions, and are found in Inuit country foods. Current community exposure to these metals can be measured in food, but feces and urine are also excellent indicators of total exposure from ingestion and inhalation because a high percentage of each metal is excreted. Bulk domestic sewage or its residue in a waste treatment system is a good substitute measure. Domestic waste treatment systems that accumulate metals in sediment provide an accurate historical record of changes in ingestion or inhalation. We collected sediment cores from an arctic lake used for facultative domestic sewage treatment to identify the history of community exposure to Pb, Cd, and Hg. Cores were dated and fluxes were measured for each metal. A nearby lake was sampled to measure combined background and atmospheric inputs, which were subtracted from sewage lake data. Pb, Cd, and Hg inputs from sewage grew rapidly after the onset of waste disposal in the late 1960s and exceeded the rate of population growth in the contributing community from 1970 to 1990. The daily per-person Pb input in 1990 (720,000 ng/person per day) exceeded the tolerable daily intake level. The Cd input (48,000 ng/person per day) and Hg input (19,000 ng/person per day) were below the respective TDI levels at the time. PMID:16203239

  6. Is the Go/No-Go Lexical Decision Task Preferable to the Yes/No Task with Developing Readers?

    ERIC Educational Resources Information Center

    Moret-Tatay, Carmen; Perea, Manuel

    2011-01-01

    The lexical decision task is probably the most common laboratory visual word identification task together with the naming task. In the usual setup, participants need to press the "yes" button when the stimulus is a word and the "no" button when the stimulus is not a word. A number of studies have employed this task with developing readers;…

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCracken, Brewster

    Through funding from the Department of Energy’s Electricity Delivery and Reliability Office, Pecan Street Inc., in partnership with Austin Energy and Oncor, developed and tested third- party data access platforms and services for Green Button offerings and for other home energy use data providers. As more utilities seek to offer Green Button-compliant data to their customers, the question continually arises of how this data can be used to help customers better manage their energy use.

  8. Hot-Button Issues for Teachers: What Every Educator Needs to Know About Leadership, Testing, Textbooks, Vouchers, and More

    ERIC Educational Resources Information Center

    Vairo, Philip D.; Marcus, Sheldon; Weiner, Max

    2007-01-01

    One of the tragedies of American education is that so many teachers do not understand or are unaware of educational issues and how they impact on their profession. There is a gap between teacher perceptions and reality and this book is a first step in closing that gap. Hot-Button Issues for Teachers is a timely, comprehensive book that addresses…

  9. Supplemental Archeological Investigations of Lower Bayou Teche, St. Mary Parish, Louisiana

    DTIC Science & Technology

    1991-08-01

    Ruler end (brass)1 ____ Buckle 1__________ Brass and inlaid shell button 1____ Chain 2 71 Cosmetic cap - gild brass inlaid with shell 1I____ 185...Molded stemnware fragment ____ _____ _____ Unidentified ______ ______1 Perfume/ Cosmetic Bottle Fragment Milk glass 2 Melted Glass Aqua1 Unidentified...major portion of the recovery (n = 122). Other metal artifacts included 2 safety pins, 1 cosmetic cap made of gilt brass inlaid with shell, 3 buttons

  10. Allelopathic effects of the aqueous extract of the leaf and seed of Leucaena leucocephala on three selected weed species

    NASA Astrophysics Data System (ADS)

    Ishak, Muhamad Safwan; Sahid, Ismail

    2014-09-01

    A laboratory experiment was conducted to study the allelopathic effects of the aqueous extract of the leaf and seed of Leucaena leucocephala. The aqueous extracts were individually tested on three selected weed species, namely goatweed (Ageratum conyzoides), coat buttons (Tridax procumbens) and lilac tasselflower (Emilia sonchifolia). The allelopathic effects of the leaf and seed extracts on germination, shoot length, root length and fresh weight of each of the selected weed species were determined. Germination of goatweed, coat buttons and lilac tasselflower were inhibited by the aqueous extracts of both the leaf and seed of L. leucocephala and was concentration dependent. Different concentrations of the aqueous extracts showed various germination patterns on the selected weeds species. Seedling length and fresh weight of goatweed, coat buttons and lilac tasselflower were reduced in response to respective increasing concentrations of the seed extracts. Maximum inhibition by the aqueous seed extract was observed more on the root rather than the shoot growth. The aqueous seed extract at T3 concentration reduced root length of goatweed, coat buttons and lilac tasselflower by 95%, 86% and 91% (of the control) respectively. The aqueous seed extract showed greater inhibitory effects than that of the aqueous leaf extract.

  11. Modified coaxial wire method for measurement of transfer impedance of beam position monitors

    NASA Astrophysics Data System (ADS)

    Kumar, Mukesh; Babbar, L. K.; Deo, R. K.; Puntambekar, T. A.; Senecha, V. K.

    2018-05-01

    The transfer impedance is a very important parameter of a beam position monitor (BPM) which relates its output signal with the beam current. The coaxial wire method is a standard technique to measure transfer impedance of the BPM. The conventional coaxial wire method requires impedance matching between coaxial wire and external circuits (vector network analyzer and associated cables). This paper presents a modified coaxial wire method for bench measurement of the transfer impedance of capacitive pickups like button electrodes and shoe box BPMs. Unlike the conventional coaxial wire method, in the modified coaxial wire method no impedance matching elements have been used between the device under test and the external circuit. The effect of impedance mismatch has been solved mathematically and a new expression of transfer impedance has been derived. The proposed method is verified through simulation of a button electrode BPM using cst studio suite. The new method is also applied to measure transfer impedance of a button electrode BPM developed for insertion devices of Indus-2 and the results are also compared with its simulations. Close agreement between measured and simulation results suggests that the modified coaxial wire setup can be exploited for the measurement of transfer impedance of capacitive BPMs like button electrodes and shoe box BPM.

  12. Distinct dynamical patterns that distinguish willed and forced actions.

    PubMed

    Garcia Dominguez, Luis; Kostelecki, Wojciech; Wennberg, Richard; Perez Velazquez, Jose L

    2011-03-01

    The neural pathways for generating willed actions have been increasingly investigated since the famous pioneering work by Benjamin Libet on the nature of free will. To better understand what differentiates the brain states underlying willed and forced behaviours, we performed a study of chosen and forced actions over a binary choice scenario. Magnetoencephalography recordings were obtained from six subjects during a simple task in which the subject presses a button with the left or right finger in response to a cue that either (1) specifies the finger with which the button should be pressed or (2) instructs the subject to press a button with a finger of their own choosing. Three independent analyses were performed to investigate the dynamical patterns of neural activity supporting willed and forced behaviours during the preparatory period preceding a button press. Each analysis offered similar findings in the temporal and spatial domains and in particular, a high accuracy in the classification of single trials was obtained around 200 ms after cue presentation with an overall average of 82%. During this period, the majority of the discriminatory power comes from differential neural processes observed bilaterally in the parietal lobes, as well as some differences in occipital and temporal lobes, suggesting a contribution of these regions to willed and forced behaviours.

  13. Double-button Fixation System for Management of Acute Acromioclavicular Joint Dislocation

    PubMed Central

    Torkaman, Ali; Bagherifard, Abolfazl; Mokhatri, Tahmineh; Haghighi, Mohammad Hossein Shabanpour; Monshizadeh, Siamak; Taraz, Hamid; Hasanvand, Amin

    2016-01-01

    Background: Surgical treatments for acromioclavicular (AC) joint dislocation present with some complications. The present study was designed to evaluate the double-button fixation system in the management of acute acromioclavicular joint dislocation. Methods: This cross sectional study, done between February 2011 to June 2014, consisted of 28 patients who underwent surgical management by the double-button fixation system for acute AC joint dislocation. Age, sex, injury mechanism, dominant hand, side with injury, length of follow up, time before surgery, shoulder and hand (DASH), constant and visual analogue scale (VAS) scores, and all complications of the cases during the follow up were recorded. Results: The mean age of patients was 33.23±6.7 years. Twenty four patients (85.71%) were male and four (14.28%) were female. The significant differences were observed between pre-operation VAS, constant shoulder scores and post-operation measurements. There were not any significant differences between right and left coracoclavicular, but two cases of heterotrophic ossifications were recorded. The mean follow-up time was 16.17±4.38 months. Conclusion: According to the results, the double-button fixation system for management of acute acromioclavicular joint dislocation has suitable results and minimal damage to the soft tissues surrounding the coracoclavicular ligaments. PMID:26894217

  14. Exposure to organophosphate flame retardants in spray polyurethane foam applicators: Role of dermal exposure.

    PubMed

    Bello, Anila; Carignan, Courtney C; Xue, Yalong; Stapleton, Heather M; Bello, Dhimiter

    2018-04-01

    Spray polyurethane foam (SPF) is a highly effective thermal insulation material that has seen considerable market growth in the past decade. Organophosphate flame retardants (PFRs) are added to SPF formulations to meet fire code requirements. A common flame retardant used in SPF formulations is tris 1-chloro 2-propyl phosphate (TCIPP), a suspected endocrine disruptor. Exposure monitoring efforts during SPF applications have focused primarily on the isocyanate component, a potent respiratory and dermal sensitizer. However, to our knowledge, there is no monitoring data for TCIPP. To characterize occupational exposures to TCIPP and other flame retardants during SPF insulation. Workers at four SPF insulation sites and one foam removal site (total n = 14) were recruited as part of this pilot study. Personal inhalation exposure to TCIPP was monitored with a CIP-10MI inhalable sampler and potential dermal exposure was assessed through the use of a glove dosimeter. Biomarkers of TCIPP and three other PFRs were measured in urine collected from workers pre-and post-shift. Linear mixed effect models were used to analyze associations of urinary biomarkers with inhalation and dermal exposures and paired t-tests were used to examine the difference on the means of urinary biomarkers pre-and post-shift. Chemical analysis of all species was performed with liquid chromatography-electrospray ionization tandem mass spectrometry. Geometric mean (GM) concentrations of TCIPP in personal air monitors and glove dosimeters collected from SPF applicators, 294.7 μg/m 3 and 18.8 mg/pair respectively. Overall, GM concentrations of the two TCIPP urinary biomarkers BCIPP and BCIPHIPP and (6.2 and 88.8 μg/mL) were 26-35 times higher than reported in the general population. Post-shift levels of TCIPP biomarkers were higher than pre-shift even though workers at insulation sites wore supplied air respirators, gloves and coveralls. The urinary biomarkers for the other PFRs were not elevated post shift. Concentrations of TCIPP on glove dosimeters were positively associated with post-shift urinary TCIPP biomarkers (p < 0.05) whereas concentrations in personal air samples were not. High levels of urinary biomarkers for TCIPP among SPF applicators, including post-shift, points to absorption of TCIPP during the work shift, in spite of the use of best industry exposure control practices. Dermal exposure appears to be an important, if not the primary exposure pathway for TCIPP, although inhalation or incidental ingestion of foam particles post-SPF application cannot be ruled out in this pilot study. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Arthroscopic Latarjet Techniques: Graft and Fixation Positioning Assessed With 2-Dimensional Computed Tomography Is Not Equivalent With Standard Open Technique.

    PubMed

    Neyton, Lionel; Barth, Johannes; Nourissat, Geoffroy; Métais, Pierre; Boileau, Pascal; Walch, Gilles; Lafosse, Laurent

    2018-05-19

    To analyze graft and fixation (screw and EndoButton) positioning after the arthroscopic Latarjet technique with 2-dimensional computed tomography (CT) and to compare it with the open technique. We performed a retrospective multicenter study (March 2013 to June 2014). The inclusion criteria included patients with recurrent anterior instability treated with the Latarjet procedure. The exclusion criterion was the absence of a postoperative CT scan. The positions of the hardware, the positions of the grafts in the axial and sagittal planes, and the dispersion of values (variability) were compared. The study included 208 patients (79 treated with open technique, 87 treated with arthroscopic Latarjet technique with screw fixation [arthro-screw], and 42 treated with arthroscopic Latarjet technique with EndoButton fixation [arthro-EndoButton]). The angulation of the screws was different in the open group versus the arthro-screw group (superior, 10.3° ± 0.7° vs 16.9° ± 1.0° [P < .001]; inferior, 10.3° ± 0.8° vs 15.7° ± 0.9° [P < .0001]). The angulation of the EndoButtons was 5.7° ± 0.5°; this was different from that of open inferior screws (P = .003). In the axial plane (level of equator), the arthroscopic techniques resulted in lateral positions (arthro-screw, 1.5 ± 0.3 mm lateral [P < .001]; arthro-EndoButton, 0 ± 0.3 mm lateral [P < .0001]) versus the open technique (0.9 ± 0.2 mm medial). At the level of 25% of the glenoid height, the arthroscopic techniques resulted in lateral positions (arthro-screw, 0.3 ± 0.3 mm lateral [P < .001]); (arthro-EndoButton, 0.7 ± 0.3 mm lateral [P < .0001]) versus the open technique (1.0 ± 0.2 mm medial). Higher variability was observed in the arthro-screw group. In the sagittal plane, the arthro-screw technique resulted in higher positions (55% ± 3% of graft below equator) and the arthro-EndoButton technique resulted in lower positions (82% ± 3%, P < .0001) versus the open technique (71% ± 2%). Variability was not different. This study shows that the position of the fixation devices and position of the bone graft with the arthroscopic techniques are statistically significantly different from those with the open technique with 2-dimensional CT assessment. In the sagittal plane, the arthro-screw technique provides the highest positions, and the arthro-EndoButton technique, the lowest. Overall, the mean position of the bone block with the open Latarjet technique in the axial plane is slightly medial to the joint line, as recommended. Conversely, with the arthroscopic techniques, the bone grafts are more lateral with a slight overhang. The main differences are observed in the dispersion of the values (more extreme positions) with the arthro-screw technique, given the acknowledged limitations. Despite the statistical significance, the clinical significance of these differences is yet unknown. Level III, retrospective comparative study. Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  16. Respiratory Protection Program medical clearance for respirator use

    NASA Technical Reports Server (NTRS)

    1993-01-01

    Background on occupational exposure to various inhalents is discussed including on-site hazard control measures, procedures, physiological effects, and interpretation of results for the medical clearance of employee for use of personal respiratory protection devices. The purpose of the Respiratory Protection Program at LeRC is outlined, and the specifics of the Medical Surveillance Program for Respiratory Protection at LeRC are discussed.

  17. Miniaturized inertial impactor for personal airborne particulate monitoring: Prototyping

    NASA Astrophysics Data System (ADS)

    Pasini, Silvia; Bianchi, Elena; Dubini, Gabriele; Cortelezzi, Luca

    2017-11-01

    Computational fluid dynamic (CFD) simulations allowed us to conceive and design a miniaturized inertial impactor able to collect fine airborne particulate matter (PM10, PM2.5 and PM1). We created, by 3D printing, a prototype of the impactor. We first performed a set of experiments by applying a suction pump to the outlets and sampling the airborne particulate of our laboratory. The analysis of the slide showed a collection of a large number of particles, spanning a wide range of sizes, organized in a narrow band located below the exit of the nozzle. In order to show that our miniaturized inertial impactor can be truly used as a personal air-quality monitor, we performed a second set of experiments where the suction needed to produce the airflow through the impactor is generated by a human being inhaling through the outlets of the prototype. To guarantee a number of particles sufficient to perform a quantitative characterization, we collected particles performing ten consecutive deep inhalations. Finally, the potentiality for realistic applications of our miniaturized inertial impactor used in combination with a miniaturized single-particle detector will be discussed. CARIPLO Fundation - project MINUTE (Grant No. 2011-2118).

  18. A Study of Selected Problems in Armor Operations

    DTIC Science & Technology

    1978-11-01

    of external environmental cond~tions on the internal environment of a buttoned-up tank. Another effort was a study of problems in escape and...Test site configuration: Study II ......... ... IV-16 FIG. IVT4. Mean time to lay on target .... ........ .... IV-20 TABLES Chapter III Table III-I...L., and Ton, W. H. Study of the Psychological (and Associated Physiological) Effjcts on a Tank Crew Resulting From Being Buttoned Up, ARI Research

  19. BPM Breakdown Potential in the PEP-II B-factory Storage Ring Collider

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weathersby, Stephen; Novokhatski, Alexander; /SLAC

    2010-02-10

    High current B-Factory BPM designs incorporate a button type electrode which introduces a small gap between the button and the beam chamber. For achievable currents and bunch lengths, simulations indicate that electric potentials can be induced in this gap which are comparable to the breakdown voltage. This study characterizes beam induced voltages in the existing PEP-II storage ring collider BPM as a function of bunch length and beam current.

  20. Consortium Requirements Engineering Guidebook

    DTIC Science & Technology

    1993-12-01

    re- quirements among developers or contractors, acquisition managers, and users. A CoRE specification serves as both the test -to and design-to...that are used for the following purposes: (1) the button labeled SELF TEST allows the operator to check the FLMS’s output hardware while the system is...shut down; and (2) the button labeled RESET allows the system to be brought back into normal operation following a shutdown or testing as long as the

  1. An ergonomics study of thumb movements on smartphone touch screen.

    PubMed

    Xiong, Jinghong; Muraki, Satoshi

    2014-01-01

    This study investigated the relationships between thumb muscle activity and thumb operating tasks on a smartphone touch screen with one-hand posture. Six muscles in the right thumb and forearm were targeted in this study, namely adductor pollicis, flexor pollicis brevis, abductor pollicis brevis (APB), abductor pollicis longus, first dorsal interosseous (FDI) and extensor digitorum. The performance measures showed that the thumb developed fatigue rapidly when tapping on smaller buttons (diameter: 9 mm compared with 3 mm), and moved more slowly in flexion-extension than in adduction-abduction orientation. Meanwhile, the electromyography and perceived exertion values of FDI significantly increased in small button and flexion-extension tasks, while those of APB were greater in the adduction-abduction task. This study reveals that muscle effort among thumb muscles on a touch screen smartphone varies according to the task, and suggests that the use of small touch buttons should be minimised for better thumb performance.

  2. A wire scanner system for characterizing the BNL energy recovery LINAC beam position monitor system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michnoff R.; Biscardi, C.; Cerniglia, P.

    2012-04-15

    A stepper motor controlled wire scanner system has recently been modified to support testing of the Brookhaven National Laboratory (BNL) Collider-Accelerator department's Energy Recovery Linac (ERL) beam position monitor (BPM) system. The ERL BPM consists of four 9.33 mm diameter buttons mounted at 90 degree spacing in a cube with 1.875 inch inside diameter. The buttons were designed by BNL and fabricated by Times Microwave Systems. Libera brilliance single pass BPM electronic modules with 700 MHz bandpass filter, manufactured by Instrumentation Technologies, will be used to measure the transverse beam positions at 14 locations around the ERL. The wire scannermore » assembly provides the ability to measure the BPM button response to a pulsed wire, and evaluate and calibrate the Libera position measurement electronics. A description of the wire scanner system and test result data will be presented.« less

  3. Paper-based piezoelectric touch pads with hydrothermally grown zinc oxide nanowires.

    PubMed

    Li, Xiao; Wang, Yu-Hsuan; Zhao, Chen; Liu, Xinyu

    2014-12-24

    This paper describes a new type of paper-based piezoelectric touch pad integrating zinc oxide nanowires (ZnO NWs), which can serve as user interfaces in paper-based electronics. The sensing functionality of these touch pads is enabled by the piezoelectric property of ZnO NWs grown on paper using a simple, cost-efficient hydrothermal method. A piece of ZnO-NW paper with two screen-printed silver electrodes forms a touch button, and touch-induced electric charges from the button are converted into a voltage output using a charge amplifier circuit. A touch pad consisting of an array of buttons can be readily integrated into paper-based electronic devices, allowing user input of information for various purposes such as programming, identification checking, and gaming. This novel design features ease of fabrication, low cost, ultrathin structure, and good compatibility with techniques in printed electronics, and further enriches the available technologies of paper-based electronics.

  4. Characterization of inhalation exposure to jet fuel among U.S. Air Force personnel.

    PubMed

    Merchant-Borna, Kian; Rodrigues, Ema G; Smith, Kristen W; Proctor, Susan P; McClean, Michael D

    2012-07-01

    Jet propulsion fuel-8 (JP-8) is the primary jet fuel used by the US military, collectively consuming ~2.5 billion gallons annually. Previous reports suggest that JP-8 is potentially toxic to the immune, respiratory, and nervous systems. The objectives of this study were to evaluate inhalation exposure to JP-8 constituents among active duty United States Air Force (USAF) personnel while performing job-related tasks, identify significant predictors of inhalation exposure to JP-8, and evaluate the extent to which surrogate exposure classifications were predictive of measured JP-8 exposures. Seventy-three full-time USAF personnel from three different air force bases were monitored during four consecutive workdays where personal air samples were collected and analyzed for benzene, ethylbenzene, toluene, xylenes, total hydrocarbons (THC), and naphthalene. The participants were categorized a priori into high- and low-exposure groups, based on their exposure to JP-8 during their typical workday. Additional JP-8 exposure categories included job title groups and self-reported exposure to JP-8. Linear mixed-effects models were used to evaluate predictors of personal air concentrations. The concentrations of THC in air were significantly different between a priori exposure groups (2.6 mg m(-3) in high group versus 0.5 mg m(-3) in low, P < 0.0001), with similar differences observed for other analytes in air. Naphthalene was strongly correlated with THC (r = 0.82, P < 0.0001) and both were positively correlated with the relative humidity of the work environment. Exposures to THC and naphthalene varied significantly by job categories based on USAF specialty codes and were highest among personnel working in fuel distribution/maintenance, though self-reported exposure to JP-8 was an even stronger predictor of measured exposure in models that explained 72% (THC) and 67% (naphthalene) of between-worker variability. In fact, both self-report JP-8 exposure and a priori exposure groups explained more between-worker variability than job categories. Personal exposure to JP-8 varied by job and was positively associated with the relative humidity. However, self-reported exposure to JP-8 was an even stronger predictor of measured exposure than job title categories, suggesting that self-reported JP-8 exposure is a valid surrogate metric of exposure when personal air measurements are not available.

  5. Coccidioidomycosis in travelers returning from Mexico--Pennsylvania, 2000.

    PubMed

    2000-11-10

    Coccidioidomycosis (CM), a fungal disease caused by Coccidioides immitis, is endemic in the southwestern United States and parts of Central and South America. The disease is acquired by inhaling the arthroconidia of C. immitis present in the soil. Outbreaks of CM occur when susceptible persons are exposed to airborne arthroconidia from dust storms, natural disasters, and earth excavation (1,2). Persons who travel to areas where the disease is endemic may become infected and develop symptoms after returning home (3,4). This report describes an outbreak of CM among travelers returning to Pennsylvania from a trip to Mexico.

  6. Multidisciplinary Consensus on the Nonadherence to Clinical Management of Inhaled Therapy in Spanish asthma patients.

    PubMed

    López-Viña, Antolín; Giner, Jordi; Molina, Jesús; Palicio, Javier; Plaza, Javier; Quintano, José Antonio; Quirce, Santiago; Soria, Cristina; Uréndez, Ana María; Plaza, Vicente

    2017-08-01

    Rates of nonadherence to asthma treatment in Spain are between 24% and 76%, which results in poor disease control and increased health care costs. The main objective of this multidisciplinary consensus was to investigate the opinions of health professionals and patients regarding adherence to inhaled therapy in Spain. The results will help to identify the causes of nonadherence and to establish strategies to detect and correct the problem. This research was conducted by using a modified Delphi method organized into 2 rounds and involving a panel of 64 physicians, 16 nurses, and 10 community pharmacists. In addition, 70 patients with asthma completed a simplified 1-round survey, based on the Delphi questionnaire. The items proposed to reach a consensus included topics such as impact and causes of nonadherence, as well as strategies to improve adherence to treatment. Expert panelists reached a consensus on ~80% of the items proposed. They agreed that the lack of control in asthma has an important economic impact. The causes of nonadherence with more agreement were the patients' beliefs about treatment and the complexity of the inhalation devices. Panelists agreed that the most important strategies to improve adherence were modification of patients' beliefs, training of professionals in the management of adherence, and personalization of interventions. Most patients only agreed with items that referred to strategies to improve adherence. Although the problems, impact, causes, and interventions regarding nonadherence to asthma treatment are known, adequate monitoring of adherence to treatment is not performed. A multidisciplinary and personalized approach is necessary to control and improve adherence. Copyright © 2017 Elsevier HS Journals, Inc. All rights reserved.

  7. The impact of cognitive impairment on self-management in chronic obstructive pulmonary disease: A systematic review.

    PubMed

    Baird, Chelsea; Lovell, Janaka; Johnson, Marilyn; Shiell, Kerrie; Ibrahim, Joseph E

    2017-08-01

    To determine the characteristics of persons with cognitive impairment being able to self-manage in chronic obstructive pulmonary disease (COPD). In accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidance this systematic review examined all studies in English from 1st January 2000 to 20 February 2016, describing the relationship between cognition and COPD self-management domains in older community dwelling persons with dementia or cognitive impairment. Of 4474 studies identified, thirteen studies were eligible for inclusion. No studies differentiated populations into recognized dementia subtypes. Study aims were variable; most (n = 7) examined inhaler competency alone. Studies identified a link between worsening cognition and the need for assistance in activities of daily living. Only one study evaluated the impact of cognition on overall self-management and found no association between cognitive impairment and self-rated self-management. Mild degrees of cognitive impairment were associated with reduced symptom recall. Cognitive impairment in COPD was associated with high degrees of inhaler incompetency. Basic cognitive screening tests were able to predict inhaler incompetence with reduced overall cognitive function, dyspraxia, and/or executive function identified as predictors of incompetency. Multiple measures of disability consistently demonstrated that cognitive impairment in COPD significantly increased the need for assistance in many aspects of daily living, treatment adherence, and effective self-management. Given the nature of neuropsychological deficits seen in COPD, dedicated screening tools are required. Future research should investigate the impact of cognitive dysfunction in COPD and identify how to support those that lack capacity to self-manage. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Exposure assessment for a nested case-control study of lung cancer among European asphalt workers.

    PubMed

    Agostini, Michela; Ferro, Gilles; Olsson, Ann; Burstyn, Igor; De Vocht, Frank; Hansen, Johnni; Lassen, Christina Funch; Johansen, Christoffer; Kjaerheim, Kristina; Langard, Sverre; Stucker, Isabelle; Ahrens, Wolfgang; Behrens, Thomas; Lindbohm, Marja-Liisa; Heikkilä, Pirjo; Heederik, Dick; Portengen, Lützen; Shaham, Judith; Boffetta, Paolo; Kromhout, Hans

    2010-10-01

    Development of a method for retrospective assessment of exposure to bitumen fume, bitumen condensate, organic vapour, polycyclic aromatic hydrocarbons, and co-exposures to known or suspected lung carcinogens for a nested case-control study of lung cancer mortality among European asphalt workers. Company questionnaires and structured questionnaires used in interviews and industry-specific job-exposure matrices (JEMs) were elaborated and applied. Three sources of information were eventually used for exposure assessment and assignment: (i) data obtained in cohort phase, (ii) data from living subjects, next-of-kin, and fellow-workers questionnaires, and (iii) JEMs for bitumen exposure by inhalation and via skin and co-exposures to known or suspected lung carcinogens within and outside cohort companies. Inhalation and dermal exposure estimates for bitumen were adjusted for time trends, time spent in a job, and other determinants of exposure (e.g. oil gravel paving). Clothing patterns, personal protective devices, and personal hygiene were taken into consideration while estimating dermal exposure. Occupational exposures could be assessed for 433 cases and 1253 controls for relevant time periods. Only 43% of work histories were spent inside original asphalt and construction companies. A total of 95.8% of job periods in cohort companies could be coded at a more detailed level. Imputation of work time and 'hygienic behaviour' multipliers was needed for <10% of work history years. Overall, downward trends in exposure were present and differences existed between countries and companies. As expected, correlations were strongest (r > 0.7) among bitumen-related agents, while correlations between coal tar, bitumen-related agents, and established lung carcinogens were weaker (r < 0.4). A systematic and detailed approach was developed to estimate inhalation and dermal exposure for a nested case-control study among asphalt workers.

  9. Exposure to grain dust in Great Britain.

    PubMed

    Spankie, Sally; Cherrie, John W

    2012-01-01

    Airborne grain dust is a complex mixture of fragments of organic material from grain, plus mineral matter from soil, and possible insect, fungal, or bacterial contamination or their toxic products, such as endotoxin. In the 1990s, grain workers in Britain were frequently exposed to inhalable dust >10 mg.m(-3) (8 h), with particularly high exposures being found at terminals where grain was imported or exported and in drying operations (personal exposure typically approximately 20 mg.m(-3)). Since then, the industry has made substantial progress in improving the control of airborne dust through better-designed processes, increased automation, and an improved focus on product quality. We have used information from the published scientific literature and a small survey of industry representatives to estimate current exposure levels. These data suggest that current long-term exposure to inhalable dust for most workers is on average less than approximately 3 mg.m(-3), with perhaps 15-20% of individual personal exposures being >10 mg.m(-3). There are no published data from Britain on short-term exposure during cleaning and other tasks. We have estimated average levels for a range of tasks and judge that the highest levels, for example during some cleaning activities and certain process tasks such as loading and packing, are probably approximately10 mg.m(-3). Endotoxin levels were judged likely to be <10⁴ EU m(-3) throughout the industry provided inhalable dust levels are <10 mg.m(-3). There are no published exposure data on mycotoxin, respirable crystalline silica, and mite contamination but these are not considered to present widespread problems in the British industry. Further research should be carried out to confirm these findings.

  10. Respiratory tract deposition efficiencies: evaluation of effects from smoke released in the Cerro Grande forest fire.

    PubMed

    Schöllnberger, H; Aden, J; Scott, B R

    2002-01-01

    Forest-fire smoke inhaled by humans can cause various health effects. This smoke contains toxic chemicals and naturally occurring radionuclides. In northern New Mexico, a large wildfire occurred in May 2000. Known as the Cerro Grande Fire, it devastated the town of Los Alamos and damaged Los Alamos National Laboratory (LANL). Residents were concerned about the possible dissemination of radionuclides from LANL via smoke from the fire. To evaluate potential health effects of inhaling radionuclides contained in the smoke from the Cerro Grande Fire, it was first necessary to evaluate how much smoke would deposit in the human respiratory tract. The purpose of this study was to evaluate respiratory-tract deposition efficiencies of airborne forest-fire smoke for persons of different ages exposed while inside their homes. Potential non-radiological health effects of a forest fire are reviewed. The deposition efficiencies presented can be used to evaluate in-home smoke deposition in the respiratory tract and expected radionuclide intake related to forest fires. The impact of smoke exposure on firemen fighting a forest fire is quantitatively discussed and compared. They primarily inhaled forest-fire smoke while outdoors where the smoke concentration was much higher than inside. Radionuclides released at the LANL site via the Cerro Grande Fire were restricted to naturally occurring radionuclides from burning trees and vegetation. Radiation doses from inhaled airborne radionuclides to individuals inside and outside the Los Alamos area were likely very small.

  11. Biomechanical evaluation of a transtibial pull-out meniscal root repair: challenging the bungee effect.

    PubMed

    Cerminara, Anthony J; LaPrade, Christopher M; Smith, Sean D; Ellman, Michael B; Wijdicks, Coen A; LaPrade, Robert F

    2014-12-01

    A common treatment for posterior meniscal root tears is transtibial pull-out repair, which has been biomechanically reported to restore tibiofemoral contact mechanics to those of the intact knee. Biomechanical data suggest that there is significant displacement of the repaired meniscal root with cyclic loading, which may be responsible for the poor healing and meniscal extrusion demonstrated in some clinical studies. The purpose of this study was to quantify the time-zero displacement of the posterior meniscal root in response to cyclic loading after transtibial pull-out repair and to quantify the individual contributions to displacement of the following: (1) suture elongation, (2) button-bone interface, and (3) meniscus-suture interface. The meniscus-suture interface was hypothesized to result in significantly more displacement than the button-bone interface or suture elongation. Descriptive laboratory study. Transtibial pull-out repair of the posterior medial meniscal root was performed in 6 porcine knees, and cyclic displacement was measured using a loading protocol representative of postoperative rehabilitation. Displacement from (1) suture elongation, (2) the button-bone interface, and (3) the meniscus-suture interface was determined by cyclically loading 6 specimens for each construct using the same loading protocol to determine the contribution of each component to the overall displacement of the repair construct. After 1000 cycles, the repair construct displaced by a mean of 3.28 mm (95% CI, 2.07-4.49). The meniscus-suture component (mean, 2.52 mm; 95% CI, 2.21-2.83) displaced significantly more than the button-bone component (mean, 0.90 mm; 95% CI, 0.64-1.15; P = .006) and suture elongation component (mean, 0.71 mm; 95% CI, 0.36-1.06; P = .006) after 1000 cycles. Displacement of the button-bone and suture elongation components was not significantly different after 1000 cycles (P = .720). There was substantial displacement of the posterior medial meniscal root repaired with the transtibial pull-out technique under a cyclic loading protocol simulating postoperative rehabilitation. The meniscus-suture interface contributed to significantly more displacement than the button-bone interface and suture elongation in the transtibial pull-out repair construct. The results provide a framework for optimizing the transtibial pull-out repair technique. Future studies should focus on improving suture fixation strength within the meniscus-suture interface. © 2014 The Author(s).

  12. Inhalation Exposure of Organophosphate Pesticides by Vegetable Growers in the Bang-Rieng Subdistrict in Thailand

    PubMed Central

    Jaipieam, Somsiri; Visuthismajarn, Parichart; Siriwong, Wattasit; Borjan, Marija; Robson, Mark G.

    2009-01-01

    This study investigated inhalation exposure to organophosphate pesticides (OPPs) and evaluated the associated health risks to vegetable growers living in the Bang-Rieng agricultural community. Air samples were collected by using personal sampling pumps with sorbent tubes placed in the vegetable growers' breathing zone. Samples were collected during both wet and dry seasons. Residues of organophosphate pesticides, that is, chlorpyrifos, dicrotofos, and profenofos, were analyzed from 33 vegetable growers and 17 reference subjects. Results showed that median concentrations of OPPs in air in farm areas were in the range of 0.022–0.056 mg/m3 and air in nonfarm areas in the range of <0.0016–<0.005 mg/m3. The concentration of the three pesticides in the vegetable growers was significantly higher than that of the references during both seasons. The results also indicate that the vegetable growers may be at risk for acute adverse effects via the inhalation of chlorpyrifos and dicrotofos during pesticide application, mixing, loading, and spraying. It is suggested that authorities and the community should implement appropriate strategies concerning risk reduction and risk management. PMID:20168980

  13. Concentrations and size distribution of inhalable and respirable dust among sugar industry workers: a pilot study in Khon Kaen, Thailand.

    PubMed

    Sakunkoo, Pornpun; Chaiear, Naesinee; Chaikittiporn, Chalermchai; Sadhra, Steven

    2011-11-01

    There has been very limited information regarding bagasse exposure among workers in sugar industries as well as on health outcomes. The authors determined the occupational exposure of sugar industry workers in Khon Kaen to airborne bagasse dust. The size of the bagasse dust ranged from 0.08 to 9 µm with the highest size concentration of 2.1 to 4.7 µm. The most common size had a geometric mean diameter of 5.2 µm, with a mass concentration of 6.89 mg/m(3)/log µm. The highest mean values of inhalable and respirable dust were found to be 9.29 mg/m(3) from February to April in bagasse storage, 5.12 mg/m(3) from May to September, and 4.12 mg/m(3) from October to January. Inhalable dust concentrations were 0.33, 0.47, and 0.41 mg/m(3), respectively. Workers are likely to be exposed to high concentrations of bagasse dust and are at risk of respiratory diseases. Preventive measures, both in the form of engineering designs and personal protective devices, should be implemented.

  14. [Contamination and Cleaning of Touch Panels Used in Everyday Life and the Awareness of Persons in Charge and Users of Devices about Contamination].

    PubMed

    Morioka, Ikuharu; Uda, Kazu; Yamamoto, Mio

    2015-01-01

    The purpose of this study was to clarify the contamination and cleaning of touch panels used in everyday life and the awareness of persons in charge and users of devices about contamination. Samples from touch panels were cultured to detect viable bacteria (n=132), Staphylococcus aureus (n=66) and Escherichia coli (n=64). A questionnaire survey was conducted on persons in charge and users of the devices on the day of sampling. Viable bacterial cells were detected in more than 90% of the automatic teller machines (ATMs) at banks, the ticket machines at stations, and the copy machines at convenience stores. S. aureus and E. coli were detected in more than one-half of such devices examined. The detection rate of viable bacterial cells in smartphones was 57.5% and was lower than those in other devices. More than 65% of the ATMs, ticket machines, and copy machines were cleaned once or twice a day. More than one-half of the users of smartphones or button-type mobile phones did not clean their devices. Those who did not aware about the contamination of touch panels were 46.6% of the persons in charge and 38.2% of the users. It is necessary to examine the suitable number of times and methods of cleaning of touch panels and to raise the awareness of persons in charge or users of such devices about contamination.

  15. Collaborative Systems and Multi-user Interfaces: Computer-based Tools for Cooperative Problem Solving

    DTIC Science & Technology

    1986-10-31

    Reference Card Given to Participants) Cognoter Reference Select = LeftButton Menu = MiddleButton TitleBar menu for tool operations Item menu for item...collaborative tools and their uses, the Colab system and the Cognoter presentation tool were implemented and used for both real and posed idea organization...tasks. To test the system design and its effect on structured problem-solving, many early Colab/ Cognoter meetings were monitored and a series of

  16. Evaluation of tooth-click triggering and speech recognition in assistive technology for computer access.

    PubMed

    Simpson, Tyler; Gauthier, Michel; Prochazka, Arthur

    2010-02-01

    Computer access can play an important role in employment and leisure activities following spinal cord injury. The authors' prior work has shown that a tooth-click detecting device, when paired with an optical head mouse, may be used by people with tetraplegia for controlling cursor movement and mouse button clicks. To compare the efficacy of tooth clicks to speech recognition and that of an optical head mouse to a gyrometer head mouse for cursor and mouse button control of a computer. Six able-bodied and 3 tetraplegic subjects used the devices listed above to produce cursor movements and mouse clicks in response to a series of prompts displayed on a computer. The time taken to move to and click on each target was recorded. The use of tooth clicks in combination with either an optical head mouse or a gyrometer head mouse can provide hands-free cursor movement and mouse button control at a speed of up to 22% of that of a standard mouse. Tooth clicks were significantly faster at generating mouse button clicks than speech recognition when paired with either type of head mouse device. Tooth-click detection performed better than speech recognition when paired with both the optical head mouse and the gyrometer head mouse. Such a system may improve computer access for people with tetraplegia.

  17. Inclusion Behavior During the Electron Beam Button Melting Test

    NASA Astrophysics Data System (ADS)

    Bellot, J. P.; Defay, B.; Jourdan, J.; Chapelle, P.; Jardy, A.

    2012-10-01

    The high mechanical performance of alloys developed for the manufacture of turbine disks depend upon the size and the number density of the inclusions. The electron beam button method has been practiced since the 1980s as a technique to quantify the cleanliness of the superalloys as well as to identify the nature and the size of the inclusions. The technique involves melting the sample into a hemispherical water-cooled crucible and the low density inclusions (mainly oxides) are concentrated by a combination of Marangoni and buoyancy forces into an area at the top surface of the button referred to as the raft. We have experimentally studied the behavior of oxide inclusions in special steels using both high definition video and infrared cameras. We have observed the inversion of the Marangoni effect due to the presence of sulfur, which leads to a positive temperature coefficient of the surface tension. A mathematical modeling has been carried out to simulate the turbulent fluid flow associated with the temperature field in the metallic pool of the button. The surface temperature profile has been successfully compared with the measured data. A post-processor numerical tool calculates the inclusion trajectories taking into account the turbulent fluctuation velocity by a stochastic approach. Hence, the behavior of a population of inclusions has been statistically studied, and the dependence of the capture efficiency on the inclusion size has been analyzed.

  18. First Case of Bioterrorism-Related Inhalational Anthrax in the United States, Palm Beach County, Florida, 2001

    PubMed Central

    Wiersma, Steven T.; Rosenstein, Nancy E.; Malecki, Jean M.; Shepard, Colin W.; Raghunathan, Pratima L.; Pillai, Segaran P.; Popovic, Tanja; Quinn, Conrad P.; Meyer, Richard F.; Zaki, Sharif R.; Kumar, Savita; Bruce, Sherrie M.; Sejvar, James J.; Dull, Peter M.; Tierney, Bruce C.; Jones, Joshua D.; Perkins, Bradley A.

    2002-01-01

    On October 4, 2001, we confirmed the first bioterrorism-related anthrax case identified in the United States in a resident of Palm Beach County, Florida. Epidemiologic investigation indicated that exposure occurred at the workplace through intentionally contaminated mail. One additional case of inhalational anthrax was identified from the index patient’s workplace. Among 1,076 nasal cultures performed to assess exposure, Bacillus anthracis was isolated from a co-worker later confirmed as being infected, as well as from an asymptomatic mail-handler in the same workplace. Environmental cultures for B. anthracis showed contamination at the workplace and six county postal facilities. Environmental and nasal swab cultures were useful epidemiologic tools that helped direct the investigation towards the infection source and transmission vehicle. We identified 1,114 persons at risk and offered antimicrobial prophylaxis. PMID:12396910

  19. Phenotype-Driven Therapeutics in Severe Asthma.

    PubMed

    Opina, Maria Theresa D; Moore, Wendy C

    2017-02-01

    Inhaled corticosteroids are the mainstay of asthma treatment using a step-up approach with incremental dosing and additional controller medications in order to achieve symptom control and prevent exacerbations. While most patients respond well to this treatment approach, some patients remain refractory despite high doses of inhaled corticosteroids and a long-acting β-agonist. The problem lies in the heterogeneity of severe asthma, which is further supported by the emergence of severe asthma phenotypes. This heterogeneity contributes to the variability in treatment response. Randomized controlled trials involving add-on therapies in poorly controlled asthma have challenged the idea of a "one size fits all" approach targeting specific phenotypes in their subject selection. This review discusses severe asthma phenotypes from unbiased clustering approaches and the most recent scientific evidence on novel treatments to provide a guide in personalizing severe asthma treatment.

  20. Improved inhalation technology for setting safe exposure levels for workplace chemicals

    NASA Technical Reports Server (NTRS)

    Stuart, Bruce O.

    1993-01-01

    Threshold Limit Values recommended as allowable air concentrations of a chemical in the workplace are often based upon a no-observable-effect-level (NOEL) determined by experimental inhalation studies using rodents. A 'safe level' for human exposure must then be estimated by the use of generalized safety factors in attempts to extrapolate from experimental rodents to man. The recent development of chemical-specific physiologically-based toxicokinetics makes use of measured physiological, biochemical, and metabolic parameters to construct a validated model that is able to 'scale-up' rodent response data to predict the behavior of the chemical in man. This procedure is made possible by recent advances in personal computer software and the emergence of appropriate biological data, and provides an analytical tool for much more reliable risk evaluation and airborne chemical exposure level setting for humans.

  1. Demographic Variability of Inhalation Mechanics: A Review

    DTIC Science & Technology

    2016-12-01

    or height. Another important consideration in terms of body size is obesity . Obesity is known to cause a scourge of health problems which can...Mean compliance of the total respiratory system and particularly compliance of the chest wall was greater in normal compared to obese individuals...Total respiratory compliance was markedly reduced by recumbency in obese individuals. Bedell et al. (43) Obese persons had reduced expiratory

  2. A Geant4 evaluation of the Hornyak button and two candidate detectors for the TREAT hodoscope

    NASA Astrophysics Data System (ADS)

    Fu, Wenkai; Ghosh, Priyarshini; Harrison, Mark J.; McGregor, Douglas S.; Roberts, Jeremy A.

    2018-05-01

    The performance of traditional Hornyak buttons and two proposed variants for fast-neutron hodoscope applications was evaluated using Geant4. The Hornyak button is a ZnS(Ag)-based device previously deployed at the Idaho National Laboratory's TRansient REActor Test Facility (better known as TREAT) for monitoring fast neutrons emitted during pulsing of fissile fuel samples. Past use of these devices relied on pulse-shape discrimination to reduce the significant levels of background Cherenkov radiation. Proposed are two simple designs that reduce the overall light guide mass (here, polymethyl methacrylate or PMMA), employ silicon photomultipliers (SiPMs), and can be operated using pulse-height discrimination alone to eliminate background noise to acceptable levels. Geant4 was first used to model a traditional Hornyak button, and for assumed, hodoscope-like conditions, an intrinsic efficiency of 0.35% for mono-directional fission neutrons was predicted. The predicted efficiency is in reasonably good agreement with experimental data from the literature and, hence, served to validate the physics models and approximations employed. Geant4 models were then developed to optimize the materials and geometries of two alternatives to the Hornyak button, one based on a homogeneous mixture of ZnS(Ag) and PMMA, and one based on alternating layers of ZnS(Ag) and PMMA oriented perpendicular to the incident neutron beam. For the same radiation environment, optimized, 5-cm long (along the beam path) devices of the homogeneous and layered designs were predicted to have efficiencies of approximately 1.3% and 3.3%, respectively. For longer devices, i.e., lengths larger than 25 cm, these efficiencies were shown to peak at approximately 2.2% and 5.9%, respectively. Moreover, both designs were shown to discriminate Cherenkov noise intrinsically by using an appropriate pulse-height discriminator level, i.e., pulse-shape discrimination is not needed for these devices.

  3. Correlation Between Corneal Button Size and Intraocular Pressure During Femtosecond Laser-Assisted Keratoplasty.

    PubMed

    Choi, Mihyun; Lee, Yong Eun; Whang, Woong-Joo; Yoo, Young-Sik; Na, Kyung-Sun; Joo, Choun-Ki

    2016-03-01

    To evaluate changes in intraocular pressure (IOP) in recipient and donor eyes during femtosecond laser-assisted keratoplasty (FLAK) and to assess for differences in the diameter of trephinated corneal buttons according to changes in pressure. Twenty porcine whole eyes (recipient model) and 20 porcine-corneoscleral rims (donor model) were prepared, and anterior chamber pressures were measured using a fiberoptic sensing device (Opsens, Quebec, Canada) during the femtosecond laser corneal cutting process. To determine the diameter of corneal buttons, 10 porcine whole eyes (recipient model) and 12 corneoscleral rims (donor model) of each baseline IOP were cut with the femtosecond laser programmed to the following pattern: "vertical side cut"; 1200 μm (depth), 8 mm (diameter). Digital photographs were obtained using microscopy and subsequently analyzed. The IOP (mean ± SD) for the recipient model was 10.2 (±0.9) mm Hg at baseline and ranged from 96.6 (±4.5) to ∼138.4 (±3.8) mm Hg during the corneal cutting process. This shows that the maximum IOP during FLAK increased 13.5 times compared with baseline. In the donor model, the mean pressure elevation from baseline artificial anterior chamber (AAC) pressure to corneal cutting was 15.8 (±5.4) mm Hg. This showed a positive correlation with baseline IOP [correlation coefficient (CC) = 0.827, P = 0.006]. As the baseline IOP in the recipient eye increased, trephinated corneal button size was reduced by up to 3.9% in diameter (CC = -0.945, P = 0.015). In addition, in donor eyes, the diameter was decreased by up to 11.7% as the baseline AAC pressure increased (CC = -0.934, P = 0.006). During the FLAK procedure, the IOP increases in both recipient and donor eyes. The diameter of the trephinated donor and recipient corneal buttons was decreased as the initial baseline IOP increased. Ophthalmic surgeons can determine the AAC pressure based on the baseline IOP in the recipient patient.

  4. A Geant4 evaluation of the Hornyak button and two candidate detectors for the TREAT hodoscope

    DOE PAGES

    Fu, Wenkai; Ghosh, Priyarshini; Harrison, Mark; ...

    2018-02-05

    The performance of traditional Hornyak buttons and two proposed variants for fast-neutron hodoscope applications was evaluated using Geant4. The Hornyak button is a ZnS(Ag)-based device previously deployed at the Idaho National Laboratory's TRansient REActor Test Facility (better known as TREAT) for monitoring fast neutrons emitted during pulsing of fissile fuel samples. Past use of these devices relied on pulse-shape discrimination to reduce the significant levels of background Cherenkov radiation. Proposed are two simple designs that reduce the overall light guide mass (here, polymethyl methacrylate or PMMA), employ silicon photomultipliers (SiPMs), and can be operated using pulse-height discrimination alone to eliminatemore » background noise to acceptable levels. Geant4 was first used to model a traditional Hornyak button, and for assumed, hodoscope-like conditions, an intrinsic efficiency of 0.35% for mono-directional fission neutrons was predicted. The predicted efficiency is in reasonably good agreement with experimental data from the literature and, hence, served to validate the physics models and approximations employed. Geant4 models were then developed to optimize the materials and geometries of two alternatives to the Hornyak button, one based on a homogeneous mixture of ZnS(Ag) and PMMA, and one based on alternating layers of ZnS(Ag) and PMMA oriented perpendicular to the incident neutron beam. For the same radiation environment, optimized, 5-cm long (along the beam path) devices of the homogeneous and layered designs were predicted to have efficiencies of approximately 1.3% and 3.3%, respectively. For longer devices, i.e., lengths larger than 25 cm, these efficiencies were shown to peak at approximately 2.2% and 5.9%, respectively. Furthermore, both designs were shown to discriminate Cherenkov noise intrinsically by using an appropriate pulse-height discriminator level, i.e., pulse-shape discrimination is not needed for these devices.« less

  5. Revision ulnar collateral ligament reconstruction using a suspension button fixation technique.

    PubMed

    Lee, Gregory H; Limpisvasti, Orr; Park, Maxwell C; McGarry, Michelle H; Yocum, Lewis A; Lee, Thay Q

    2010-03-01

    Revision ulnar collateral ligament reconstruction remains a challenging problem. The objective of this study was to biomechanically evaluate an ulnar collateral ligament reconstruction technique using a suspension button fixation technique that can be used even in the case of ulnar cortical bone loss. An ulnar suspension fixation technique for ulnar collateral ligament reconstruction can restore elbow kinematics and demonstrate failure strength comparable to that of currently available techniques. Controlled laboratory study. Nine pairs of cadaveric elbows were dissected free of soft tissue and potted. After simulating ulnar cortical bone loss, ulnar collateral ligament reconstruction was performed in 1 elbow of each pair using palmaris longus autograft and a 30-mm RetroButton suspended from the far (lateralmost) ulnar cortex. A docking technique was used for humeral fixation of the graft. Elbow valgus angle was quantified using a Microscribe 3DLX digitizer at multiple elbow flexion angles. Valgus angle was measured with the ulnar collateral ligament intact, transected, and reconstructed. In addition, load-to-failure testing was performed in 1 elbow of each pair. Release of the ulnar collateral ligament caused a significant increase in valgus angle at each flexion angle tested (P < .002). Reconstructed elbows demonstrated no significant differences in valgus angle from the intact elbow at all flexion angles tested. Load-to-failure tests showed that reconstructed elbows had an ultimate torque (10.3 + or - 5.7 N x m) significantly less than intact elbows (26.4 + or - 10.6 N x m) (P = .001). Ulnar collateral ligament reconstruction using a suspension button fixation technique reliably restored elbow kinematics to the intact state. Load-to-failure testing demonstrated comparable fixation strength to several historic controls of primary reconstruction techniques despite the simulated ulnar cortical bone loss. Ulnar collateral ligament reconstruction using a suspension button fixation technique can be considered in the case of ulnar cortical bone loss in a primary or revision setting.

  6. Arthroscopically assisted reduction of acute acromioclavicular joint dislocation using a single double-button device: Medium-term clinical and radiological outcomes.

    PubMed

    Issa, S-P; Payan, C; Le Hanneur, M; Loriaut, P; Boyer, P

    2018-02-01

    Double-button devices for endoscopic management of acute acromioclavicular joint dislocation (ACJD) provide satisfactory short-term functional and radiological results. However, little exists in the literature regarding the long- and medium-term results of these implants, especially regarding the evolution of the acromioclavicular joint (ACJ). Satisfactory and steady long- and medium-term outcomes can be achieved in patients with acute ACJD undergoing endoscopically assisted ACJ repair using a single double-button device. A retrospective single-center study was conducted in patients with acute Rockwood III and IV ACJD treated endoscopically with a single double-button device from October 2008 to October 2010, allowing a minimum 5-year follow-up. Functional evaluation used Constant and Quick-DASH scores. Clinical evidence of dislocation recurrence was combined with bilateral Zanca views to assess coracoclavicular distance. Acromioclavicular osteoarthritis was evaluated on the Paxinos test and Zanca views. Nineteen of the 25 operated patients were seen at a mean 76.9±8.5 months' follow-up. Mean age was 34.4±8.3 years. Mean Constant and Quick-DASH scores were 96.2±5.1 and 0.9±1.6 points, respectively. Four patients had a recurrence of their initial dislocation, 3 of whom had positive Paxinos test, whereas the 15 patients without recurrence had a negative test (p=0.004). Five patients had radiological evidence of ACJ osteoarthritis: all 4 patients with recurrence and 1 without (p=0.001). Long- and medium-term radioclinical outcome of endoscopically assisted management of acute ACJD using a single double-button device seems to be satisfactory and steady over time. Recurrence of the initial dislocation appears to be related to onset of degenerative ACJ arthropathy. Therapeutic type IV-Retrospective case series. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  7. Investigation into pedestrian exposure to near-vehicle exhaust emissions

    PubMed Central

    2009-01-01

    Background Inhalation of diesel particulate matter (DPM) is known to have a negative impact on human health. Consequently, there are regulations and standards that limit the maximum concentrations to which persons may be exposed and the maximum concentrations allowed in the ambient air. However, these standards consider steady exposure over large spatial and time scales. Due to the nature of many vehicle exhaust systems, pedestrians in close proximity to a vehicle's tailpipe may experience events where diesel particulate matter concentrations are high enough to cause acute health effects for brief periods of time. Methods In order to quantify these exposure events, instruments which measure specific exhaust constituent concentrations were placed near a roadway and connected to the mouth of a mannequin used as a pedestrian surrogate. By measuring concentrations at the mannequin's mouth during drive-by events with a late model diesel truck, a representative estimate of the exhaust constituent concentrations to which a pedestrian may be exposed was obtained. Typical breathing rates were then multiplied by the measured concentrations to determine the mass of pollutant inhaled. Results The average concentration of diesel particulate matter measured over the duration of a single drive-by test often exceeded the low concentrations used in human clinical studies which are known to cause acute health effects. It was also observed that higher concentrations of diesel particulate matter were measured at the height of a stroller than were measured at the mouth of a mannequin. Conclusion Diesel particulate matter concentrations during drive-by incidents easily reach or exceed the low concentrations that can cause acute health effects for brief periods of time. For the case of a particularly well-tuned late-model year vehicle, the mass of particulate matter inhaled during a drive-by incident is small compared to the mass inhaled daily at ambient conditions. On a per breath basis, however, the mass of particulate matter inhaled is large compared to the mass inhaled at ambient conditions. Finally, it was determined that children, infants, or people breathing at heights similar to that of a passing vehicle's tailpipe may be exposed to higher concentrations of particulate matter than those breathing at higher locations, such as adults standing up. PMID:19331669

  8. Investigation of Optically Induced Avalanching in GaAs

    DTIC Science & Technology

    1989-06-01

    by Bovino , et al 4 to increase the hold off voltage. The button switch design of Fig. 4c has been used by several researchers5 ’ 7 to obtain the...ul Long flashover palh Figure 3b. 434 Optical Jlatlern a. Mourou Switch b. Bovino Switch c. Button Switch Figure 4. Photoconductive Switches...Technology and Devices Laboratory, ERADCOM (by L. Bovino , et. all) 4 • The deposition recipe for the contacts is 1) 50 ANi (provides contact to GaAs

  9. Design and Implementation of an Operations Module for the ARGOS paperless Ship System

    DTIC Science & Technology

    1989-06-01

    A. OPERATIONS STACK SCRIPTS SCRIPTS FOR STACK: operations * BACKGROUND #1: Operations * on openStack hide message box show menuBar pass openStack end... openStack ** CARD #1, BUTTON #1: Up ***** on mouseUp visual effect zoom out go to card id 10931 of stack argos end mouseUp ** CARD #1, BUTTON #2...STACK SCRIPTS SCRIPTS FOR STACK: Reports ** BACKGROUND #1: Operations * on openStack hie message box show menuBar pass openStack end openStack ** CARD #1

  10. Sealing Penetrating Eye Injuries Using Photoactivated Bonding

    DTIC Science & Technology

    2010-09-30

    on  corneal tissue. To evaluate inflammation all 15 rabbits will be euthanized with  phenobarbital . The  10 corneoscleral button of tissue will be...will be euthanized with  phenobarbital . The  corneoscleral button of tissue will be removed and divided into portions for paraffin and frozen sections

  11. Study of Psychological (and Associated Physiological) Effects on a Tank Crew Resulting from Being Buttoned Up

    DTIC Science & Technology

    1976-10-01

    should he made for either ixiternal storage or a means of voiding the urinal in a storage container in the compartment’. Development of-Adequate...upper temperature ranges fu- critical components of the M60 tank under desert storage and operational conditions. He found that the Wet Bulb Globe...five-gallon cans on the outside turret bustle racks. If buttoned-up operations for extended periods of time are envisioned, a built-in water storage

  12. Energy Saving in Electric Lighting for the United States Army.

    DTIC Science & Technology

    1979-10-05

    these reasons. Avoid devices such as power saving buttons which are to be placed in the sockets of incandescent bulbs. They are merely half-wave...using the button or a long-life bulb. Another device to avoid is the pulse or transient suppressor. This device, essentially a voltage clipper...arranged In a geo- metric pattern. It is used to shield a lamp from Lumen: A unit of light output from a lamp. view at certain angles to avoid glare from

  13. Far Forward Life Support System (FFLSS) Phase II

    DTIC Science & Technology

    2001-05-01

    button will clear audible, flashing , or constant red alarms. Pushing the Config button drops down to the Level 2 menu (bottom line of Figure 8). In...disabled. Again, with testing this audible noise can be disabled. The visual flashing or constant red cannot be disabled. Pushing Return goes back to Level...Calling PLOTPIXEL( x ,y) and PLOTLINE(xl,x2,yl,y2) is as simple as pushing the appropriate bytes (unsigned integers) onto the stack and jumping to the

  14. The structure of affective action representations: temporal binding of affective response codes.

    PubMed

    Eder, Andreas B; Müsseler, Jochen; Hommel, Bernhard

    2012-01-01

    Two experiments examined the hypothesis that preparing an action with a specific affective connotation involves the binding of this action to an affective code reflecting this connotation. This integration into an action plan should lead to a temporary occupation of the affective code, which should impair the concurrent representation of affectively congruent events, such as the planning of another action with the same valence. This hypothesis was tested with a dual-task setup that required a speeded choice between approach- and avoidance-type lever movements after having planned and before having executed an evaluative button press. In line with the code-occupation hypothesis, slower lever movements were observed when the lever movement was affectively compatible with the prepared evaluative button press than when the two actions were affectively incompatible. Lever movements related to approach and avoidance and evaluative button presses thus seem to share a code that represents affective meaning. A model of affective action control that is based on the theory of event coding is discussed.

  15. Investigation of He-W interactions using DiMES on DIII-D

    NASA Astrophysics Data System (ADS)

    Doerner, R. P.; Rudakov, D. L.; Chrobak, C. P.; Briesemeister, A. R.; Corr, C.; De Temmerman, G.; Kluth, P.; Lasnier, C. J.; McLean, A. G.; Pace, D. C.; Pitts, R. A.; Schmitz, O.; Thompson, M.; Winters, V.

    2016-02-01

    Tungsten button samples were exposed to He ELMing H-mode plasma in DIII-D using 2.3 MW of electron cyclotron heating power. Prior to the exposures, the W buttons were exposed to either He, or D, plasma in PISCES-A for 2000 s at surface temperatures of 225-850 °C to create a variety of surfaces (surface blisters, subsurface nano-bubbles, fuzz). Erosion was spectroscopically measured from each DiMES sample, with the exception of the fuzzy W samples which showed almost undetectable WI emission. Post-exposure grazing incidence small angle x-ray scattering surface analysis showed the formation of 1.5 nm diameter He bubbles in the surface of W buttons after only a single DIII-D (3 s, ˜150 ELMs) discharge, similar to the bubble layer resulting from the 2000 s. exposure in PISCES-A. No surface roughening, or damage, was detected on the samples after approximately 600 ELMs with energy density between 0.04-0.1 MJ m-2.

  16. A novel wearable smart button system for fall detection

    NASA Astrophysics Data System (ADS)

    Zhuang, Wei; Sun, Xiang; Zhi, Yueyan; Han, Yue; Mao, Hande

    2017-05-01

    Fall has been the second most cause of accidental injury to death in the world. It has been a serious threat to the physical and mental health of the elders. Therefore, developing wearable node system with fall detecting ability has become increasingly pressing at present. A novel smart button for long-term fall detection is proposed in this paper, which is able to accurately monitor the falling behavior, and sending warning message online as well. The smart button is based on the tri-axis acceleration sensor which is used to collect the body motion signals. By using the statistical metrics of acceleration characteristics, a new SVM classification algorithm with high positive accuracy and stability is proposed so as to classify the falls and activities of daily living, and the results can be real-time displayed on Android based mobile phone. The experiments show that our wearable node system can continuously monitor the falling behavior with positive rate 94.8%.

  17. Site-Specific Reference Person Parameters and Derived Concentration Standards for the Savannah River Site

    DOE PAGES

    Stone, Daniel K.; Higley, Kathryn A.; Jannik, G. Timothy

    2014-05-01

    The U.S. Department of Energy Order 458.1 states that the compliance with the 1 mSv annual dose constraint to a member of the public may be demonstrated by calculating dose to the maximally exposed individual (MEI) or to a representative person. Historically, the MEI concept was used for dose compliance at the Savannah River Site (SRS) using adult dose coefficients and adult male usage parameters. For future compliance, SRS plans to use the representative person concept for dose estimates to members of the public. The representative person dose will be based on the reference person dose coefficients from the U.S.more » DOE Derived Concentration Technical Standard and on usage parameters specific to SRS for the reference and typical person. Usage parameters and dose coefficients were determined for inhalation, ingestion and external exposure pathways. The parameters for the representative person were used to calculate and tabulate SRS-specific derived concentration standards (DCSs) for the pathways not included in DOE-STD-1196-2011.« less

  18. Release of beryllium from mineral ores in artificial lung and skin surface fluids.

    PubMed

    Duling, Matthew G; Stefaniak, Aleksandr B; Lawrence, Robert B; Chipera, Steve J; Virji, M Abbas

    2012-06-01

    Exposure to some manufactured beryllium compounds via skin contact or inhalation can cause sensitization. A portion of sensitized persons who inhale beryllium may develop chronic beryllium disease (CBD). Little is understood about exposures to naturally occurring beryllium minerals. The purpose of this study was to assess the bioaccessibility of beryllium from bertrandite ore. Dissolution of bertrandite from two mine pits (Monitor and Blue Chalk) was evaluated for both the dermal and inhalation exposure pathways by determining bioaccessibility in artificial sweat (pH 5.3 and pH 6.5), airway lining fluid (SUF, pH 7.3), and alveolar macrophage phagolysosomal fluid (PSF, pH 4.5). Significantly more beryllium was released from Monitor pit ore than Blue Chalk pit ore in artificial sweat buffered to pH 5.3 (0.88 ± 0.01% vs. 0.36 ± 0.00%) and pH 6.5 (0.09 ± 0.00% vs. 0.03 ± 0.01%). Rates of beryllium released from the ores in artificial sweat were faster than previously measured for manufactured forms of beryllium (e.g., beryllium oxide), known to induce sensitization in mice. In SUF, levels of beryllium were below the analytical limit of detection. In PSF, beryllium dissolution was biphasic (initial rapid diffusion followed by latter slower surface reactions). During the latter phase, dissolution half-times were 1,400 to 2,000 days, and rate constants were ~7 × 10(-10) g/(cm(2)·day), indicating that bertrandite is persistent in the lung. These data indicate that it is prudent to control skin and inhalation exposures to bertrandite dusts.

  19. Beam Diagnostics of the Compton Scattering Chamber in Jefferson Lab's Hall C

    NASA Astrophysics Data System (ADS)

    Faulkner, Adam; I&C Group Collaboration

    2013-10-01

    Upcoming experimental runs in Hall C will utilize Compton scattering, involving the construction and installation of a rectangular beam enclosure. Conventional cylindrical stripline-style Beam Position Monitors (BPMs) are not appropriate due to their form factor; therefore to facilitate measurement of position, button-style BPMs are being considered due to the ease of placement within the new beam enclosure. Button BPM experience is limited at JLAB, so preliminary measurements are needed to characterize the field response, and guide the development of appropriate algorithms for the Analog to Digital receiver systems. -field mapping is performed using a Goubau Line (G-Line), which employs a surface wave to mimic the electron beam, helping to avoid problems associated with vacuum systems. Potential algorithms include simplistic 1/r modeling (-field mapping), look-up-tables, as well as a potential third order power series fit. In addition, the use of neural networks specifically the multi-layer Perceptron will be examined. The models, sensor field maps, and utility of the neural network will be presented. Next steps include: modification of the control algorithm, as well as to run an in-situ test of the four Button electrodes inside of a mock beam enclosure. The analysis of the field response using Matlab suggests the button BPMs are accurate to within 10 mm, and may be successful for beam diagnostics in Hall C. More testing is necessary to ascertain the limitations of the new electrodes. The National Science Foundation, Old Dominion University, The Department of Energy, and Jefferson Lab.

  20. Death from Nitrous Oxide.

    PubMed

    Bäckström, Björn; Johansson, Bengt; Eriksson, Anders

    2015-11-01

    Nitrous oxide is an inflammable gas that gives no smell or taste. It has a history of abuse as long as its clinical use, and deaths, although rare, have been reported. We describe two cases of accidental deaths related to voluntary inhalation of nitrous oxide, both found dead with a gas mask covering the face. In an attempt to find an explanation to why the victims did not react properly to oncoming hypoxia, we performed experiments where a test person was allowed to breath in a closed system, with or without nitrous oxide added. Vital signs and gas concentrations as well as subjective symptoms were recorded. The experiments indicated that the explanation to the fact that neither of the descendents had reacted to oncoming hypoxia and hypercapnia was due to the inhalation of nitrous oxide. This study raises the question whether nitrous oxide really should be easily, commercially available. © 2015 American Academy of Forensic Sciences.

  1. Multiple food allergy.

    PubMed

    Speer, F

    1975-02-01

    This paper is devoted to a study of multiple food allergy, here defined as sensitivity to three or more foods. The purpose of the study is to report findings obtained from a study of 250 private patients and to show what type of persons develop this condition, how it affects them, and what their common allergens are. It was found that multiple food allergy occurs in both sexes and at all ages but is more common in boys than in girls and more common in women then in men. The clinical manifestations were much like those caused by the more familiar inhalant allergy but with a much more widespread constitutional disturbance. The great majority of patients (86%) also reacted to such air-borne allergens as molds, pollens, house dust, and animal epithelials. This indicates that food allergy and inhalant allergy are fundamentally the same phenomenon. The common food allergens were such everyday foods as milk, chocolate, corn, egg, tomato, peanut, and citrus fruits.

  2. Respiratory effects among rubberwood furniture factory workers in Thailand.

    PubMed

    Sriproed, Salakjit; Osiri, Pramuk; Sujirarat, Dusit; Chantanakul, Suttinun; Harncharoen, Kitiphong; Ong-artborirak, Parichat; Woskie, Susan R

    2013-01-01

    Respiratory symptoms and pulmonary function were examined among 89 rubberwood furniture factory workers. Acute and chronic irritant symptoms were assessed, lung function was measured both pre- and post-shift and personal inhalable dust exposure determined. The only symptoms with a significant increase among high dust level-exposed workers (>1 mg/m(3)) were those related to nasal irritation. High dust level-exposed workers had a significant cross-shift decrease in forced expiratory volume in 1 second/forced vital capacity (FEV(1)/FVC) compared with low dust level-exposed workers and increases in inhalable dust concentration levels (mg/m(3)) were significantly associated with decreases in the peak expiratory flow (PEF) across the work shift. For percent predicted pulmonary function levels, a significant decrement in PEF was found for high versus low rubberwood dust level-exposed workers, after controlling for confounders. These findings suggest the need for an occupational standard for rubberwood dust in Thailand.

  3. BioSim (trademark) BG Non-Biological Aerosol Simulant

    DTIC Science & Technology

    2004-11-17

    39.5 1.36 1,1- difluoroethane HFA 152a – Not used for pharmaceutical inhalers , is used for personal products Boiling point (-13o F) 63 (psig... 1 BIOSIMTM BG NON-BIOLOGICAL AEROSOL SIMULANT David S. Alburty, Kelly L. Brown, Jennifer L. Dannehl and Andrew E. Page Midwest...BioSafey Level 1 regulations. All of these materials of biological origin pose challenging logistics problems including safety issues, cost

  4. Gram-positive Rod Surveillance for Early Anthrax Detection

    PubMed Central

    Begier, Elizabeth M.; Barrett, Nancy L.; Mshar, Patricia A.; Johnson, David G.

    2005-01-01

    Connecticut established telephone-based gram-positive rod (GPR) reporting primarily to detect inhalational anthrax cases more quickly. From March to December 2003, annualized incidence of blood isolates was 21.3/100,000 persons; reports included 293 Corynebacterium spp., 193 Bacillus spp., 73 Clostridium spp., 26 Lactobacillus spp., and 49 other genera. Around-the-clock GPR reporting has described GPR epidemiology and enhanced rapid communication with clinical laboratories. PMID:16229790

  5. The development of a test system for investigating the performances of personal aerosol samplers under actual workplace conditions.

    PubMed

    Botham, R A; Hughson, G W; Vincent, J H; Mark, D

    1991-10-01

    The performances of new "total" aerosol samplers for use in workplaces are required to match the inhalability criteria as contained in the latest recommendations of the International Standards Organization (ISO) and the American Conference of Governmental Industrial Hygienists (ACGIH). In the past, practical evaluations have been carried out under idealized conditions in wind tunnels, and there is now the need to extend these to more realistic workplace conditions. This paper describes a new test system that was designed and built for this purpose. It consisted of a life-size mannequin mounted on a trolley so that it can be taken to and wheeled around in workplaces. The mannequin itself incorporated a robotic arm so that, under joystick control, it can be made to simulate a range of worker movements, orientations, and attitudes. An electronically controlled, compact breathing machine provided a range of typical breathing parameters for the mannequin. The pump also provided air movement for a number of personal samplers that were mounted on the torso of the mannequin and tested in that position. Sampler performance should be assessed by comparing directly the aerosol collected by the sampler with that inhaled by the mannequin (and collected on filters inside the head).

  6. Atmospheric thorium pollution and inhalation exposure in the largest rare earth mining and smelting area in China.

    PubMed

    Wang, Lingqing; Zhong, Buqing; Liang, Tao; Xing, Baoshan; Zhu, Yifang

    2016-12-01

    Exposure to radionuclide thorium (Th) has generated widespread public concerns, mainly because of its radiological effects on human health. Activity levels of airborne 232 Th in total suspended particulate (TSP) were measured in the vicinity of the largest rare earth mine in China in August 2012 and March 2013. The mean activity concentrations of 232 Th in TSP ranged from 820μBqm -3 in a mining area in August 2012 to 39,720μBqm -3 in a smelting area in March 2013, much higher than the world reference of 0.5μBqm -3 . Multistatistical analysis and Kohonen's self-organizing maps suggested that 232 Th in TSP was mainly derived from rare earth mining and smelting practices. In addition, personal inhalation exposures to 232 Th associated with respirable particulate (PM 10 ) were also measured among local dwellers via personal monitoring. The mean dose values for different age groups in the smelting and mining areas ranged from 97.86 to 417μSvyear - 1 and from 101.03 to 430.83μSvyear -1 , respectively. These results indicate that people living in the study areas are exposed to high levels of widespread 232 Th. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. [Methods of use and behavior of cocaine addicts consulting medical-legal emergency units in Paris. Clinical aspects and urinary toxicology profile].

    PubMed

    Bécour, Bertrand; Menet, Marie-Claude; Questel, Frank; Guyon, François; Diamant-Berger, Odile

    2003-03-01

    Establish the epidemiological characteristics and urinary toxicological profiles of a population of cocaine addicts under police custody. A series of 60 cocaine addicts consulting the medico-legal emergency unit of the Hôtel-Dieu hospital in Paris was studied prospectively on the following elements: clinical characteristics, method of cocaine administration and association with other licit or illicit substances. Urinary toxicological analysis, using immuno-chemistry and chromatography linked to a mass spectrometer was systematically proposed to each patient. Half of the 17 to 26 year-old patients declared having consumed cocaine for the past 2 to 5 years. Inhalation of the vapours and the intravenous route were used more than the cigarette or nasal route. The majority of 26 to 35 year-olds were multi-drug addicted, generally associating cocaine, heroine and tobacco. Analysis of the urine provided an objective assessment of the cocaine consumption of these persons under police custody in Paris. Screening for urinary toxicity gives better knowledge on the consumption of addictive products by the person in whom urine was sampled. This study was conducted in cocaine addicts under police custody, and for the majority were social misfits. In this population, the consumption of crack by inhalation predominated.

  8. Alarm inhalation dosemeter for long living radioactive dust due to an uncontrolled release

    NASA Astrophysics Data System (ADS)

    Streil, T.; Oeser, V.; Rambousky, R.; Buchholz, F. W.

    2008-08-01

    MyRIAM is the acronym for My Radioactivity In Air Monitor and points out that the device was designed for personal use to detect any radioactivity in the air at the place and at the moment of danger. The active air sampling process enables a detection limit several orders of magnitude below that of Gamma detectors. Therefore, it is the unique way to detect dangerous exposures in time. Individual protection against inhalation of long living radioactive dust (LLRD) saves human life and health. LLRD may occur in natural environment as well as in case of nuclear accidence or military and terrorist attacks. But in any case, the immediate warning of the population is of great importance. Keep in mind: it is very easy to avoid LLRD inhalation—but you have to recognize the imminent danger. The second requirement of gap-less documentation and reliable assessment of any derived LLRD exposure is building the link to Dosimetry applications. The paper demonstrates the possibility to design small and low cost air samplers, which can be used as personal alarm dosimeters and fulfil the requirements mentioned above. Several test measurements taken by a mobile phone sized MyRIAM, shall be used to demonstrate the correctness of this statement.

  9. Inhalation but not transdermal resorption of hand sanitizer ethanol causes positive ethyl glucuronide findings in urine.

    PubMed

    Arndt, Torsten; Schröfel, Stefanie; Güssregen, Brunhilde; Stemmerich, Karsten

    2014-04-01

    Ethyl glucuronide (EtG) in urine is considered a specific marker of recent ethanol consumption. There is an ongoing debate about whether inhalation or transdermal resorption of sanitizer ethanol is the underlying cause for positive EtG findings after hand disinfection. Desderman(®) pure (Schülke & Mayr GmbH, Norderstedt) with 78.2g 96% (v/v) ethanol/100g and approx. 10% 2-propanol was used for multiple hand disinfection without and under an exhauster. Simulating a common working day in a clinic, 5 co-workers of our lab used the sanitizer 32 fold within 8h and 2 persons were merely exposed to the sanitizer vapor but without any dermal sanitizer contact. Any additional ethanol intake or exposition was reliably excluded. Spot urine was collected at baseline, after 1, 2, 4, 6 … 14, and finally 24h after the first sanitizer use. A validated LC-MS/MS was used for MRM and MS(3) of EtG and qualitative analyses of ethyl sulfate and 2-propyl glucuronide. Multiple hand disinfection caused positive EtG findings of up to 2.1mg/L or 1.7mg/g creatinine in 4 out of 5 test persons and even of 0.6mg/L or 0.8mg/g for 2 controls which were merely exposed to the sanitizer vapor but without any sanitizer contact. EtG results between the clinical (0.5mg/g) and the forensic (0.1mg/g) cut-off were obtained even 6h after the last sanitizer exposition. An exhauster prevented the sanitizer vapor inhalation and reduced the EtG excretion to mostly below the detection limit of 0.02mg/g. The maximum value was 0.09mg/g. Ethyl sulfate and 2-propyl glucuronide (2-PpG) were detectable only in the EtG positive samples. 2-PpG is a metabolite of 2-propanol, which is quite frequently used in disinfectants. Thus, the detection of this substance can be used in cases of odd EtG results as an indicator of (unintended) sanitizer exposition. Ethanol from hand sanitizers is predominantly incorporated by the respiratory tract but not via the skin. It can cause a distinct ethyl glucuronide excretion and thus analytically true-positive but forensically false-positive EtG findings in the urine of ethanol abstaining persons. Since accidental ethanol inhalation can occur quite frequently in the working place or even private household, such a situation should always be considered when EtG is used as a marker of recent ethanol consumption. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  10. Carbon Nanotube and Nanofiber Exposure Assessments: An Analysis of 14 Site Visits.

    PubMed

    Dahm, Matthew M; Schubauer-Berigan, Mary K; Evans, Douglas E; Birch, M Eileen; Fernback, Joseph E; Deddens, James A

    2015-07-01

    Recent evidence has suggested the potential for wide-ranging health effects that could result from exposure to carbon nanotubes (CNT) and carbon nanofibers (CNF). In response, the National Institute for Occupational Safety and Health (NIOSH) set a recommended exposure limit (REL) for CNT and CNF: 1 µg m(-3) as an 8-h time weighted average (TWA) of elemental carbon (EC) for the respirable size fraction. The purpose of this study was to conduct an industrywide exposure assessment among US CNT and CNF manufacturers and users. Fourteen total sites were visited to assess exposures to CNT (13 sites) and CNF (1 site). Personal breathing zone (PBZ) and area samples were collected for both the inhalable and respirable mass concentration of EC, using NIOSH Method 5040. Inhalable PBZ samples were collected at nine sites while at the remaining five sites both respirable and inhalable PBZ samples were collected side-by-side. Transmission electron microscopy (TEM) PBZ and area samples were also collected at the inhalable size fraction and analyzed to quantify and size CNT and CNF agglomerate and fibrous exposures. Respirable EC PBZ concentrations ranged from 0.02 to 2.94 µg m(-3) with a geometric mean (GM) of 0.34 µg m(-3) and an 8-h TWA of 0.16 µg m(-3). PBZ samples at the inhalable size fraction for EC ranged from 0.01 to 79.57 µg m(-3) with a GM of 1.21 µg m(-3). PBZ samples analyzed by TEM showed concentrations ranging from 0.0001 to 1.613 CNT or CNF-structures per cm(3) with a GM of 0.008 and an 8-h TWA concentration of 0.003. The most common CNT structure sizes were found to be larger agglomerates in the 2-5 µm range as well as agglomerates >5 µm. A statistically significant correlation was observed between the inhalable samples for the mass of EC and structure counts by TEM (Spearman ρ = 0.39, P < 0.0001). Overall, EC PBZ and area TWA samples were below the NIOSH REL (96% were <1 μg m(-3) at the respirable size fraction), while 30% of the inhalable PBZ EC samples were found to be >1 μg m(-3). Until more information is known about health effects associated with larger agglomerates, it seems prudent to assess worker exposure to airborne CNT and CNF materials by monitoring EC at both the respirable and inhalable size fractions. Concurrent TEM samples should be collected to confirm the presence of CNT and CNF. Published by Oxford University Press on behalf of the British Occupational Hygiene Society 2015.

  11. Emissions of fluorides from welding processes.

    PubMed

    Szewczyńska, Małgorzata; Pągowska, Emilia; Pyrzyńska, Krystyna

    2015-11-01

    The levels of fluoride airborne particulates emitted from welding processes were investigated. They were sampled with the patented IOM Sampler, developed by J. H. Vincent and D. Mark at the Institute of Occupational Medicine (IOM), personal inhalable sampler for simultaneous collection of the inhalable and respirable size fractions. Ion chromatography with conductometric detection was used for quantitative analysis. The efficiency of fluoride extraction from the cellulose filter of the IOM sampler was examined using the standard sample of urban air particle matter SRM-1648a. The best results for extraction were obtained when water and the anionic surfactant N-Cetyl-N-N-N-trimethylammonium bromide (CTAB) were used in an ultrasonic bath. The limits of detection and quantification for the whole procedure were 8μg/L and 24μg/L, respectively. The linear range of calibration was 0.01-10mg/L, which corresponds to 0.0001-0.1mg of fluorides per m(3) in collection of a 20L air sample. The concentration of fluorides in the respirable fraction of collected air samples was in the range of 0.20-1.82mg/m(3), while the inhalable fraction contained 0.23-1.96mg/m(3) of fluorides during an eight-hour working day in the welding room. Copyright © 2015. Published by Elsevier B.V.

  12. Re-Engineering the United States Marine Corps’ Enlisted Assignment Model (EAM)

    DTIC Science & Technology

    1998-06-01

    and Execution button opens the switchboard in Figure 12. This form accesses all of the VBA code that is associated with this form and the code that...the prototype to prompt the user and to inform him of what he is about to do. Each of the buttons that are on these forms is connected to an SQL ...into the field for building a rule are the values 2;3;4;5;6;7. The user can enter an SQL statement that would determine the values or the user could

  13. ALLTEM System User’s Manual, Munitions Management Projects, ALLTEM Multi-Axis Electromagnetic Induction System Demonstration and Validation, Version 1.0

    DTIC Science & Technology

    2012-03-05

    Alarm button. Under the GPS frame are two smaller frames. On the left is a frame with buttons labeled Tractor Guidance and Acquisition Error... GPS ) and the Attitude Heading Reference System (AHRS) data. 5.2 Using the Data Acquisition Simulator Software The simulator and a practice set... acquisition for one polarity of the TX (33ms dead band for relay switching + 33 ms of waveforms). When the GPS is being used this is usually “1”, but may be

  14. Aging persons' estimates of vehicular motion.

    PubMed

    Schiff, W; Oldak, R; Shah, V

    1992-12-01

    Estimated arrival times of moving autos were examined in relation to viewer age, gender, motion trajectory, and velocity. Direct push-button judgments were compared with verbal estimates derived from velocity and distance, which were based on assumptions that perceivers compute arrival time from perceived distance and velocity. Experiment 1 showed that direct estimates of younger Ss were most accurate. Older women made the shortest (highly cautious) estimates of when cars would arrive. Verbal estimates were much lower than direct estimates, with little correlation between them. Experiment 2 extended target distances and velocities of targets, with the results replicating the main findings of Experiment 1. Judgment accuracy increased with target velocity, and verbal estimates were again poorer estimates of arrival time than direct ones, with different patterns of findings. Using verbal estimates to approximate judgments in traffic situations appears questionable.

  15. Risks of fatal cancer from inhalation of 239,240plutonium by humans: a combined four-method approach with uncertainty evaluation.

    PubMed

    Grogan, H A; Sinclair, W K; Voillequé, P G

    2001-05-01

    The risk per unit dose to the four primary cancer sites for plutonium inhalation exposure (lung, liver, bone, bone marrow) is estimated by combining the risk estimates that are derived from four independent approaches. Each approach represents a fundamentally different source of data from which plutonium risk estimates can be derived. These are: (1) epidemiologic studies of workers exposed to plutonium; (2) epidemiologic studies of persons exposed to low-LET radiation combined with a factor for the relative biological effectiveness (RBE) of plutonium alpha particles appropriate for each cancer site of concern; (3) epidemiologic studies of persons exposed to alpha-emitting radionuclides other than plutonium; and (4) controlled studies of animals exposed to plutonium and other alpha-emitting radionuclides extrapolated to humans. This procedure yielded the following organ-specific estimates of the distribution of mortality risk per unit dose from exposure to plutonium expressed as the median estimate with the 5th to 95th percentiles of the distribution in parentheses: lung 0.13 Gy(-1) (0.022-0.53 Gy(-1)); liver 0.057 Gy(-1) (0.011-0.47 Gy(-1)); bone 0.0013 Gy(-1) (0.000060-0.025 Gy(-1)); bone marrow (leukemia), 0.013 Gy(-1) (0.00061-0.05 Gy(-1)). Because the different tissues do not receive the same dose following an inhalation exposure, the mortality risk per unit intake of activity via inhalation of a 1-microm AMAD plutonium aerosol also was determined. To do this, inhalation dose coefficients based on the most recent ICRP models and accounting for input parameter uncertainties were combined with the risk coefficients described above. The following estimates of the distribution of mortality risk per unit intake were determined for a 1-microm AMAD plutonium aerosol with a geometric standard deviation of 2.5: lung 5.3 x 10(-7) Bq(-1) (0.65-35 x 10(-7) Bq(-1)), liver 1.2 x 10(-7) Bq(-1) (0.091-20 x 10(-7) Bq(-1)), bone 0.11 x 10(-7) Bq(-1) (0.0030-4.3 x 10(-7) Bq(-1)), bone marrow (leukemia) 0.049 x 10(-7) Bq(-1) (0.0017-0.59 x 10(-7) Bq(-1)). The cancer mortality risk for all sites was estimated to be 10 x 10(-7) Bq(-1) (2.1-55 x 10(-7) Bq(-1))--a result that agrees very well with other recent estimates. The large uncertainties in the risks per unit intake of activity reflect the combined uncertainty in the dose and risk coefficients.

  16. Computer modeling of airway deposition distribution of Foster(®) NEXThaler(®) and Seretide(®) Diskus(®) dry powder combination drugs.

    PubMed

    Jókay, Ágnes; Farkas, Árpád; Füri, Péter; Horváth, Alpár; Tomisa, Gábor; Balásházy, Imre

    2016-06-10

    Asthma is a serious global health problem with rising prevalence and treatment costs. Due to the growing number of different types of inhalation devices and aerosol drugs, physicians often face difficulties in choosing the right medication for their patients. The main objectives of this study are (i) to elucidate the possibility and the advantages of the application of numerical modeling techniques in aerosol drug and device selection, and (ii) to demonstrate the possibility of the optimization of inhalation modes in asthma therapy with a numerical lung model by simulating patient-specific drug deposition distributions. In this study we measured inhalation parameter values of 25 healthy adult volunteers when using Foster(®) NEXThaler(®) and Seretide(®) Diskus(®). Relationships between emitted doses and patient-specific inhalation flow rates were established. Furthermore, individualized emitted particle size distributions were determined applying size distributions at measured flow rates. Based on the measured breathing parameter values, we calculated patient-specific drug deposition distributions for the active components (steroid and bronchodilator) of both drugs by the help of a validated aerosol lung deposition model adapted to therapeutic aerosols. Deposited dose fractions and deposition densities have been computed in the entire respiratory tract, in distinct anatomical regions of the airways and at the level of airway generations. We found that Foster(®) NEXThaler(®) deposits more efficiently in the lungs (average deposited steroid dose: 42.32±5.76% of the nominal emitted dose) than Seretide(®) Diskus(®) (average deposited steroid dose: 24.33±2.83% of the nominal emitted dose), but the variance of the deposition values of different individuals in the lung is significant. In addition, there are differences in the required minimal flow rates, therefore at certain patients Seretide(®) Diskus(®) or pMDIs could be a better choice. Our results show that validated computer deposition models could be useful tools in providing valuable deposition data and assisting health professionals in the personalized drug selection and delivery optimization. Patient-specific modeling could open a new horizon in the treatment of asthma towards a more effective personalized medicine in the future. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Estimating Supplies Program: Evaluation Report

    DTIC Science & Technology

    2002-12-24

    Inhalation, Non-vaccinated1, Incubating, Asymptomatic 352 Anthrax, Inhalation, Non-vaccinated, Prodromal 353 Anthrax, Inhalation, Non-vaccinated, Acute...B-11 PC Code PC Description 354 Anthrax, Inhalation, Vaccinated, Asymptomatic 355 Anthrax, Inhalation, Vaccinated, Prodromal 356...Anthrax, Inhalation, Vaccinated, Acute 357 Plague, Inhalation, Incubating, Asymptomatic 358 Plague, Inhalation, Acute 359 Plague Meningitis 360

  18. Adolescent epidemic hysteria presenting as a mass casualty, toxic exposure incident

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Selden, B.S.

    Discussed is a case of explosive epidemic hysteria presenting as a mass casualty, toxic inhalation incident. Fifteen adolescent female students were triaged from a school of 700 persons exposed to sewer gas and arrived simultaneously at the emergency department complaining of a variety of nonspecific symptoms without physical findings. These symptoms quickly remitted with reassurance and dispersion of the group. Factors important in the recognition and treatment of epidemic hysteria are presented.

  19. Pathophysiology of esophageal impairment due to button battery ingestion.

    PubMed

    Völker, Johannes; Völker, Christine; Schendzielorz, Philipp; Schraven, Sebastian P; Radeloff, Andreas; Mlynski, Robert; Hagen, Rudolf; Rak, Kristen

    2017-09-01

    The increased use of button batteries with high energy densities in devices of daily life presents a high risk of injury, especially for toddlers and young children. If an accidental ingestion of a button battery occurs, this foreign body can become caught in the constrictions of the esophagus and cause serious damage to the adjacent tissue layers. The consequences can be ulcerations, perforations with fistula formation and damage to the surrounding anatomical structures. In order to gain a better understanding of the pathophysiology after ingestion, we carried out systematic studies on fresh preparations of porcine esophagi. The lithium button battery type CR2032, used most frequently in daily life, was exposed in preparations of porcine esophagi and incubated under the addition of artificial saliva at 37 °C. A total of eight esophagi were analysed by different methods. Measurements of the pH value around the battery electrodes and histological studies of the tissue damage were carried out after 0.5-24 h exposure time. In addition, macroscopic time-lapse images were recorded. Measurements of the battery voltage and the course of the electric current supplemented the experiments. The investigations showed that the batteries caused an electrolysis reaction in the moist environment. The positive electrode formed an acidic and the negative electrode a basic medium. Consequently, a coagulation necrosis at the positive pole, and a deep colliquation necrosis at the minus pole occurred. After an exposure time of 12 h, tissue damage caused by the lye corrosion was observed on the side of the negative electrode up to the lamina muscularis. The corrosion progressed up to the final exposure time of 24 h, but the batteries still had sufficient residual voltage, such that further advancing damage would be expected. Button battery ingestion in humans poses an acute life-threatening danger and immediate endoscopic removal of the foreign body is essential. After only 2 h exposure time, significant damage to the tissue could be detected, which progressed continuously to complete esophageal perforation. The primary prevention of battery ingestion is therefore of particular importance. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Transient human auditory cortex activation during volitional attention shifting

    PubMed Central

    Uhlig, Christian Harm; Gutschalk, Alexander

    2017-01-01

    While strong activation of auditory cortex is generally found for exogenous orienting of attention, endogenous, intra-modal shifting of auditory attention has not yet been demonstrated to evoke transient activation of the auditory cortex. Here, we used fMRI to test if endogenous shifting of attention is also associated with transient activation of the auditory cortex. In contrast to previous studies, attention shifts were completely self-initiated and not cued by transient auditory or visual stimuli. Stimuli were two dichotic, continuous streams of tones, whose perceptual grouping was not ambiguous. Participants were instructed to continuously focus on one of the streams and switch between the two after a while, indicating the time and direction of each attentional shift by pressing one of two response buttons. The BOLD response around the time of the button presses revealed robust activation of the auditory cortex, along with activation of a distributed task network. To test if the transient auditory cortex activation was specifically related to auditory orienting, a self-paced motor task was added, where participants were instructed to ignore the auditory stimulation while they pressed the response buttons in alternation and at a similar pace. Results showed that attentional orienting produced stronger activity in auditory cortex, but auditory cortex activation was also observed for button presses without focused attention to the auditory stimulus. The response related to attention shifting was stronger contralateral to the side where attention was shifted to. Contralateral-dominant activation was also observed in dorsal parietal cortex areas, confirming previous observations for auditory attention shifting in studies that used auditory cues. PMID:28273110

  1. Correlating bilayer tablet delamination tendencies to micro-environmental thermodynamic conditions during pan coating.

    PubMed

    Zacour, Brian M; Pandey, Preetanshu; Subramanian, Ganeshkumar; Gao, Julia Z; Nikfar, Faranak

    2014-06-01

    The objective of this study was to determine the impact that the micro-environment, as measured by PyroButton data loggers, experienced by tablets during the pan coating unit operation had on the layer adhesion of bilayer tablets in open storage conditions. A full factorial design of experiments (DOE) with three center points was conducted to study the impact of final tablet hardness, film coating spray rate and film coating exhaust temperature on the delamination tendencies of bilayer tablets. PyroButton data loggers were placed (fixed) at various locations in a pan coater and were also allowed to freely move with the tablet bed to measure the micro-environmental temperature and humidity conditions of the tablet bed. The variance in the measured micro-environment via PyroButton data loggers accounted for 75% of the variance in the delamination tendencies of bilayer tablets on storage (R(2 )= 0.75). A survival analysis suggested that tablet hardness and coating spray rate significantly impacted the delamination tendencies of the bilayer tablets under open storage conditions. The coating exhaust temperature did not show good correlation with the tablets' propensity to crack indicating that it was not representative of the coating micro-environment. Models created using data obtained from the PyroButton data loggers outperformed models created using primary DOE factors in the prediction of bilayer tablet strength, especially upon equipment or scale transfers. The coating micro-environment experienced by tablets during the pan coating unit operation significantly impacts the strength of the bilayer interface of tablets on storage.

  2. Results of minimal invasive coracoclavicular fixation by double button lift-up system in Neer type II distal clavicle fractures.

    PubMed

    Dedeoğlu, Süleyman Semih; İmren, Yunus; Çabuk, Haluk; Çakar, Murat; Arslan, Samet Murat; Esenyel, Cem Zeki

    2017-01-01

    We aimed to evaluate clinical and functional outcomes of indirect fracture reduction performed by coracoclavicular fixation with minimal invasive double button lift-up system in Neer type IIa unstable fractures of distal clavicle. 22 patients with Neer type 2 distal clavicle fracture were enrolled in that prospective study. All patients underwent indirect reduction and osteosynthesis performed by coracoclavicular fixation with minimal invasive double button lift-up system. Postoperative follow-up was carried out clinically and radiologically with plain X-rays and utilization of Constant and American Shoulder and Elbow Surgeons Standardized Shoulder Assessment (ASES) shoulder scores. Mean follow-up time was 15 months. A standard sling was applied for 2 weeks, postoperatively. Rehabilitation program was started on postoperative day 1. Mean age was 39 (range: 21-60), 18 of the patients were male. Right dominant extremity was affected in 14 patients. Mean duration of the surgical intervention was 40 min (range: 30-55 min). Mean union time was found to be 14 weeks (range: 7-21 weeks). Mean postoperative ASES and Constant scores were 79.9 (66.9-88.3) and 82.2 (71-100), respectively. The duration of return to normal daily activities were found to be 4.5 months. Any loss of reduction, AC joint arthrosis, and clavicular shortening were not detected in X-rays. This study has demonstrated that indirect osteosynthesis performed by coracoclavicular fixation with double button lift-up system in the treatment of unstable Neer type IIa fractures of the distal clavicle had successful clinical, radiological, and functional outcomes.

  3. Esophageal lesions following button-battery ingestion in children: Analysis of causes and proposals for preventive measures.

    PubMed

    Lahmar, J; Célérier, C; Garabédian, E N; Couloigner, V; Leboulanger, N; Denoyelle, F

    2018-04-01

    To study recent cases of esophageal injury due to button-battery ingestion in children presenting in pediatric ENT emergency departments of the Paris area of France (Île-de-France region), in order to propose appropriate preventive measures. A retrospective descriptive single-center study included all children under 15 years of age, presenting in pediatric ENT emergency departments between January 2008 and April 2014 for button-battery ingestion with esophageal impaction requiring emergency removal. Twenty-two boys and 4 girls, with a median age of 25 months, were included. Twenty-five of the 26 batteries had diameters of 20mm or more. Median esophageal impaction time was 7 hours 30 minutes (range, 2 to 72 hours). The complications rate was 23%. Mean hospital stay cost was €38,751 (range, €5130-119,737). The origin of the battery was known in 23 of the 26 cases: remote control without screw-secured compartment (42.3%), open battery pack (15.4%), children's toy (15.3%), camera (7.7%), watch (1 case) and hearing aid without screw-secured compartment (1 case). Esophageal lesions due to ingestion of button-batteries in children are almost always due to batteries larger than 20mm in diameter, mostly from devices with a poorly protected compartment, or batteries that are not individually packaged. These lesions cause serious complications in a quarter of cases and their management entails high health costs. Legislation requiring screw-secured compartments and individual blisters for batteries could have prevented 69.2% of the ingestions. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  4. Development of a tool for calculating early internal doses in the Fukushima Daiichi nuclear power plant accident based on atmospheric dispersion simulation

    NASA Astrophysics Data System (ADS)

    Kurihara, Osamu; Kim, Eunjoo; Kunishima, Naoaki; Tani, Kotaro; Ishikawa, Tetsuo; Furuyama, Kazuo; Hashimoto, Shozo; Akashi, Makoto

    2017-09-01

    A tool was developed to facilitate the calculation of the early internal doses to residents involved in the Fukushima Nuclear Disaster based on atmospheric transport and dispersion model (ATDM) simulations performed using Worldwide version of System for Prediction of Environmental Emergency Information 2nd version (WSPEEDI-II) together with personal behavior data containing the history of the whereabouts of individul's after the accident. The tool generates hourly-averaged air concentration data for the simulation grids nearest to an individual's whereabouts using WSPEEDI-II datasets for the subsequent calculation of internal doses due to inhalation. This paper presents an overview of the developed tool and provides tentative comparisons between direct measurement-based and ATDM-based results regarding the internal doses received by 421 persons from whom personal behavior data available.

  5. [Poisonings with the herbicides glyphosate and glyphosate-trimesium].

    PubMed

    Mortensen, O S; Sørensen, F W; Gregersen, M; Jensen, K

    2000-08-28

    Generally the herbicide glyphosate is considered harmless to humans. Glyphosate-trimesium is labelled harmful (Xn), whereas glyphosate-isopropylamine carries no warning sign. As cases of serious poisoning have emerged contacts to the Poison Information Centre have been reviewed. The persons exposed were mainly smaller children and adults 20 to 59 years of age. Oral exposure was recorded in 47 persons, inhalation exposure in 24 and topical contact in 42. About one fourth of the exposed persons were asymptomatic. Most of the symptomatic poisonings demonstrated complaints from the mouth, the gastrointestinal tract and the airways. Eleven patients were admitted to hospital. Two died, one of them having ingested the isopropylamine salt, the other the trimesium salt. Death ensued quickly in the latter patient. A similar fate was observed in a child--not included in the present material--who had also ingested the trimesium compound.

  6. User interface customization on Endoscopy Department Mini-PACS and its impact on examination workflow

    NASA Astrophysics Data System (ADS)

    Osada, Masakazu; Kaise, Mitsuru; Ozeki, Takeshi; Tsunakawa, Hirofumi; Tsunakawa, Kiyoshi; Takayanagi, Takashi; Suzuki, Nobuaki; Miwa, Jun; Ohta, Yasuhiko; Kanai, Koichi

    1999-07-01

    We have proposed a new user interface with workflow customization, implemented and evaluted in Endoscopy Department Mini-PACS that has been introduced and routinely used for two years at Toshiba General Hospital. We have set some task at endoscopy image acquisition units during examinations for two different types of user interfaces and compared performance. One is a command-button based operation using a remote control, and another is that with eight graphic buttons which are displayed on a CRT monitor and can be customized. Results of the two-year study show that mean number of input diagnosis codes per examination with graphic and customized interface is significantly greater than that with conventional interface. Also, mean time to complete one upper gastric endoscopy examination with new user interface is about 17 percent less than that with conventional interface. These result suggest that systems with the visualized and customized operation and feedback encourages physicians to use more functions and to compete tasks more efficiently than systems with conventional command-button based user interfaces.

  7. Concepts for multi-IFU robotic positioning systems

    NASA Astrophysics Data System (ADS)

    Miziarski, Stan; Brzeski, Jurek; Bland Hawthorn, Joss; Gilbert, James; Goodwin, Michael; Heijmans, Jeroen; Horton, Anthony; Lawrence, Jon; Saunders, Will; Smith, Greg A.; Staszak, Nicholas

    2012-09-01

    Following the successful commissioning of SAMI (Sydney-AAO Multi-object IFU) the AAO has undertaken concept studies leading to a design of a new instrument for the AAT (Hector). It will use an automated robotic system for the deployment of fibre hexabundles to the focal plane. We have analysed several concepts, which could be applied in the design of new instruments or as a retrofit to existing positioning systems. We look at derivatives of Starbugs that could handle a large fibre bundle as well as modifications to pick and place robots like 2dF or OzPoz. One concept uses large magnetic buttons that adhere to a steel field plate with substantial force. To move them we replace the gripper with a pneumatic device, which engages with the button and injects it with compressed air, thus forming a magnet preloaded air bearing allowing virtually friction-less repositioning of the button by a gantry or an R-Theta robot. New fibre protection, guiding and retraction systems are also described. These developments could open a practical avenue for the upgrade to a number of instruments.

  8. Early event-related brain potentials that reflect interest for content information in the media.

    PubMed

    Adachi, Shinobu; Morikawa, Koji; Nittono, Hiroshi

    2012-03-28

    This study investigated the relationship between event-related brain potentials (ERPs) to abridged content information in the media and the subsequent decisions to view the full content. Student volunteers participated in a task that simulated information selection on the basis of the content information. Screenshots of television clips and headlines of news articles on the Web were used as content information for the image condition and the headline condition, respectively. Following presentation of a stimulus containing content information, participants decided whether or not they would view the full content by pressing a select or a reject button. When the select button was pressed, participants were presented with a television clip or a news article. When the reject button was pressed, participants continued on to the next trial, without viewing further. In comparison with rejected stimuli, selected stimuli elicited a larger negative component, with a peak latency of ∼250 ms. The increase in the negative component was independent of the type of visual stimulus. These results suggest that interest toward content information is reflected in early-stage event-related brain potential responses.

  9. Investigation of He–W interactions using DiMES on DIII-D

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doerner, R. P.; Rudakov, D. L.; Chrobak, C. P.

    Here, tungsten button samples were exposed to He ELMing H-mode plasma in DIII-D using 2.3 MW of electron cyclotron heating power. Prior to the exposures, the W buttons were exposed to either He, or D, plasma in PISCES-A for 2000 s at surface temperatures of 225–850 °C to create a variety of surfaces (surface blisters, subsurface nano-bubbles, fuzz). Erosion was spectroscopically measured from each DiMES sample, with the exception of the fuzzy W samples which showed almost undetectable WI emission. Post-exposure grazing incidence small angle x-ray scattering surface analysis showed the formation of 1.5 nm diameter He bubbles in themore » surface of W buttons after only a single DIII-D (3 s, ~150 ELMs) discharge, similar to the bubble layer resulting from the 2000 s. exposure in PISCES-A. No surface roughening, or damage, was detected on the samples after approximately 600 ELMs with energy density between 0.04–0.1 MJ m –2.« less

  10. Investigation of He–W interactions using DiMES on DIII-D

    DOE PAGES

    Doerner, R. P.; Rudakov, D. L.; Chrobak, C. P.; ...

    2016-01-22

    Here, tungsten button samples were exposed to He ELMing H-mode plasma in DIII-D using 2.3 MW of electron cyclotron heating power. Prior to the exposures, the W buttons were exposed to either He, or D, plasma in PISCES-A for 2000 s at surface temperatures of 225–850 °C to create a variety of surfaces (surface blisters, subsurface nano-bubbles, fuzz). Erosion was spectroscopically measured from each DiMES sample, with the exception of the fuzzy W samples which showed almost undetectable WI emission. Post-exposure grazing incidence small angle x-ray scattering surface analysis showed the formation of 1.5 nm diameter He bubbles in themore » surface of W buttons after only a single DIII-D (3 s, ~150 ELMs) discharge, similar to the bubble layer resulting from the 2000 s. exposure in PISCES-A. No surface roughening, or damage, was detected on the samples after approximately 600 ELMs with energy density between 0.04–0.1 MJ m –2.« less

  11. Health Risk Assessment of Inhalation Exposure to Formaldehyde and Benzene in Newly Remodeled Buildings, Beijing

    PubMed Central

    Huang, Lihui; Mo, Jinhan; Sundell, Jan; Fan, Zhihua; Zhang, Yinping

    2013-01-01

    Objective To assess health risks associated with inhalation exposure to formaldehyde and benzene mainly emitted from building and decoration materials in newly remodeled indoor spaces in Beijing. Methods We tested the formaldehyde and benzene concentrations in indoor air of 410 dwellings and 451 offices remodeled within the past year, in which the occupants had health concerns about indoor air quality. To assess non-carcinogenic health risks, we compared the data to the health guidelines in China and USA, respectively. To assess carcinogenic health risks, we first modeled indoor personal exposure to formaldehyde and benzene using the concentration data, and then estimated the associated cancer risks by multiplying the indoor personal exposure by the Inhalation Unit Risk values (IURs) provided by the U.S. EPA Integrated Risk Information System (U.S. EPA IRIS) and the California Office of Environmental Health Hazard Assessment (OEHHA), respectively. Results (1) The indoor formaldehyde concentrations of 85% dwellings and 67% offices were above the acute Reference Exposure Level (REL) recommended by the OEHHA and the concentrations of all tested buildings were above the chronic REL recommended by the OEHHA; (2) The indoor benzene concentrations of 12% dwellings and 32% offices exceeded the reference concentration (RfC) recommended by the U.S. EPA IRIS; (3) The median cancer risks from indoor exposure to formaldehyde and benzene were 1,150 and 106 per million (based on U.S. EPA IRIS IURs), 531 and 394 per million (based on OEHHA IURs). Conclusions In the tested buildings, formaldehyde exposure may pose acute and chronic non-carcinogenic health risks to the occupants, whereas benzene exposure may pose chronic non-carcinogenic risks to the occupants. Exposure to both compounds is associated with significant carcinogenic risks. Improvement in ventilation, establishment of volatile organic compounds (VOCs) emission labeling systems for decorating and refurbishing materials are recommended to reduce indoor VOCs exposure. PMID:24244522

  12. Personal exposure of dairy workers to dust, endotoxin, muramic acid, ergosterol, and ammonia on large-scale dairies in the high plains Western United States.

    PubMed

    Davidson, Margaret E; Schaeffer, Joshua; Clark, Maggie L; Magzamen, Sheryl; Brooks, Elizabeth J; Keefe, Thomas J; Bradford, Mary; Roman-Muniz, Noa; Mehaffy, John; Dooley, Gregory; Poole, Jill A; Mitloehner, Frank M; Reed, Sue; Schenker, Marc B; Reynolds, Stephen J

    2018-03-01

    Dairy workers experience a high degree of bioaerosol exposure, composed of an array of biological and chemical constituents, which have been tied to adverse health effects. A better understanding of the variation in the magnitude and composition of exposures by task is needed to inform worker protection strategies. To characterize the levels and types of exposures, 115 dairy workers grouped into three task categories on nine farms in the high plains Western United States underwent personal monitoring for inhalable dust, endotoxin, 3-hydroxy fatty acids (3-OHFA), muramic acid, ergosterol, and ammonia through one work shift. Eighty-nine percent of dairy workers were exposed to endotoxin at concentrations exceeding the recommended exposure guidelines (adjusted for a long work shift). The proportion of workers with exposures exceeding recommended guidelines was lower for inhalable dust (12%), and ammonia (1%). Ergosterol exposures were only measurable on 28% of samples, primarily among medical workers and feed handlers. Milking parlor workers were exposed to significantly higher inhalable dust, endotoxin, 3-OHFA, ammonia, and muramic acid concentrations compared to workers performing other tasks. Development of large modern dairies has successfully made progress in reducing worker exposures and lung disease prevalence. However, exposure to endotoxin, dust, and ammonia continues to present a significant risk to worker health on North American dairies, especially for workers in milking parlors. This study was among the first to concurrently evaluate occupational exposure to assayable endotoxin (lipid A), 3-hydroxy fatty acids or 3-OHFA (a chemical measure of cell bound and noncell-bound endotoxins), muramic acid, ergosterol, and ammonia among workers on Western U.S. dairies. There remains a need for cost-effective, culturally acceptable intervention strategies integrated in OHS Risk Management and production systems to further optimize worker health and farm productivity.

  13. What Orthopaedic Operating Room Surfaces Are Contaminated With Bioburden? A Study Using the ATP Bioluminescence Assay.

    PubMed

    Richard, Raveesh Daniel; Bowen, Thomas R

    2017-07-01

    Contaminated operating room surfaces can increase the risk of orthopaedic infections, particularly after procedures in which hardware implantation and instrumentation are used. The question arises as to how surgeons can measure surface cleanliness to detect increased levels of bioburden. This study aims to highlight the utility of adenosine triphosphate (ATP) bioluminescence technology as a novel technique in detecting the degree of contamination within the sterile operating room environment. What orthopaedic operating room surfaces are contaminated with bioburden? When energy is required for cellular work, ATP breaks down into adenosine biphosphate (ADP) and phosphate (P) and in that process releases energy. This process is inherent to all living things and can be detected as light emission with the use of bioluminescence assays. On a given day, six different orthopaedic surgery operating rooms (two adult reconstruction, two trauma, two spine) were tested before surgery with an ATP bioluminescence assay kit. All of the cases were considered clean surgery without infection, and this included the previously performed cases in each sampled room. These rooms had been cleaned and prepped for surgery but the patients had not been physically brought into the room. A total of 13 different surfaces were sampled once in each room: the operating room (OR) preparation table (both pre- and postdraping), OR light handles, Bovie machine buttons, supply closet countertops, the inside of the Bair Hugger™ hose, Bair Hugger™ buttons, right side of the OR table headboard, tourniquet machine buttons, the Clark-socket attachment, and patient positioners used for total hip and spine positioning. The relative light units (RLUs) obtained from each sample were recorded and data were compiled and averaged for analysis. These values were compared with previously published ATP benchmark values of 250 to 500 RLUs to define cleanliness in both the hospital and restaurant industries. All surfaces had bioburden. The ATP RLUs (mean ± SD) are reported for each surface in ascending order: the OR preparation table (postdraping; 8.3 ± 3.4), inside the sterilized pan (9.2 ± 5.5), the inside of the Bair Hugger™ hose (212.5 ± 155.7), supply closet countertops (281.7 ± 236.7), OR light handles (647.8 ± 903.7), the OR preparation table (predraping; 1054 ± 387.5), the Clark-socket attachment (1135.7 ± 705.3), patient positioners used for total hip and spine positioning (1201.7 ± 1144.9), Bovie machine buttons (1264.5 ± 638.8), Bair Hugger™ buttons (1340.8 ± 1064.1), tourniquet machine buttons (1666.5 ± 2144.9), computer keyboard (1810.8 ± 929.6), and the right side of the OR table headboard (2539 ± 5635.8). ATP bioluminescence is a novel method to measure cleanliness within the orthopaedic OR and can help identify environmental trouble spots that can potentially lead to increased infection rates. Future studies correlating ATP bioluminescence findings with microbiology cultures could add to the clinical utility of this technology. Surfaces such as the undersurface of the OR table headboard, Bair Hugger™ buttons, and tourniquet machine buttons should be routinely cleansed as part of an institutional protocol. Although correlation between ATP bioluminescence and clinical infection was not evaluated in this study, it is the subject of future research. Specifically, evaluating microbiology samples taken from these environmental surfaces and correlating them with increased bioburden found with ATP bioluminescence technology can help promote improved surgical cleaning practices.

  14. [Occupational exposure to silica dust by selected sectors of national economy in Poland based on electronic database].

    PubMed

    Bujak-Pietrek, Stella; Mikołajczyk, Urszula; Szadkowska-Stańczyk, Irena; Stroszejn-Mrowca, Grazyna

    2008-01-01

    To evaluate occupational exposure to dusts, the Nofer Institute of Occupational Medicine in Łódź, in collaboration with the Chief Sanitary Inspectorate, has developed the national database to store the results of routine dust exposure measurements performed by occupational hygiene and environmental protection laboratories in Poland in the years 2001-2005. It was assumed that the collected information will be useful in analyzing workers' exposure to free crystalline silica (WKK)-containing dusts in Poland, identyfing exceeded hygiene standards and showing relevant trends, which illustrate the dynamics of exposure in the years under study. Inhalable and respirable dust measurement using personal dosimetry were done according to polish standard PN-91/Z-04030/05 and PN-91/Z-04030/06. In total, 148 638 measurement records, provided by sanitary inspection services from all over Poland, were entered into the database. The database enables the estimation of occupational exposure to dust by the sectors of national economy, according to the Polish Classification of Activity (PKD) and by kinds of dust. The highest exposure level of inhalable and respirable dusts was found in coal mining. Also in this sector, almost 60% of surveys demonstrated exceeded current hygiene standards. High concentrations of both dust fractions (inhalable and respirable) and a considerable percentage of measurements exceeding hygiene standards were found in the manufacture of transport equipment (except for cars), as well as in the chemical, mining (rock, sand, gravel, clay mines) and construction industries. The highest percentage of surveys (inhalable and respirable dust) showing exceeded hygiene standards were observed for coal dust with different content of crystalline silica, organic dust containing more than 10% of SiO2, and highly fibrosis dust containing more than 50% of SiO2.

  15. Physiological and affective reactivity to a 35% CO₂ inhalation challenge in individuals differing in the 5-HTTLPR genotype and trait neuroticism.

    PubMed

    Verschoor, Ellen; Markus, C Rob

    2012-08-01

    The inhalation of 35% carbon dioxide (CO₂) results in an acute stress response in healthy individuals and may accordingly provide a good paradigm to examine potential vulnerability factors for stress reactivity and stress-related psychopathology. It has been proposed that CO₂ reactivity is moderated by genetic (5-HTTLPR) and personality (neuroticism) factors, yet no experimental study has investigated their effects on CO₂ reactivity simultaneously. The current study examined the singular and interactive effects of the 5-HTTLPR genotype and neuroticism in predicting the affective and physiological response to a 35% CO₂ challenge in a healthy sample of male and female students. From a large group of 771 students, 48 carriers of the low/low expressing allele (S/S, S/Lg, Lg/Lg) and 48 carriers of the high/high expressing allele (La/La) with the lowest and the highest neuroticism scores (77 females, 19 males; mean age ± SD: 20.6 ± 2 years) were selected and underwent a 35% CO₂ inhalation. Visual analogue scales for anxiety and discomfort and the Panic Symptom List were used to assess affective symptomatology, while salivary samples and heart rate were assessed to establish the physiological response. A typical pattern of responses to CO₂ was observed, characterised by increases in anxiogenic symptoms and physical panic symptomatology and a reduction in heart rate; however, no effect on salivary cortisol concentration was observed. Additionally, the CO₂ reactivity did not differ between groups divided by the 5-HTTLPR genotype or neuroticism. Findings of the current study do not support a role for singular or interactive effects of the 5-HTTLPR genotype and trait neuroticism on affective and physiological reactivity to a 35% CO₂ inhalation procedure. Copyright © 2011 Elsevier B.V. and ECNP. All rights reserved.

  16. New evaluation index for the retainability of a swimmer's horizontal posture.

    PubMed

    Watanabe, Yasunori; Wakayoshi, Kohji; Nomura, Teruo

    2017-01-01

    This study aims to investigate the effect of changes in buoyancy when a swimmer respires in a horizontal posture. We attempted to evaluate the levelness of swimmers' streamline posture by simultaneously measuring the lung capacity and buoyancy under water. The buoyancy was measured based on the changes in the vertical loads of the upper and lower limbs on the subjects' streamline posture under water. The horizontal x-axis as lung ventilation and the vertical y-axis as buoyancy forms a linear equation y = ax + b. The relation between hand (upper-limb) buoyancy and lung ventilation is defined as y = a1x + b1 and that between foot (lower-limb) buoyancy and lung ventilation as y = a2x + b2. Horizontal levelness was calculated as a ratio by dividing a2 by a1 using the inclination (a) values from these formulas for an underwater streamline posture. We defined this ratio as the breathing-balance (BB) ratio. Although the performance levels in the present study did not show any difference in the absolute quantity of air that humans can inhale in a streamline posture, the BB ratio was higher in a statistically significant manner in junior swimmers competing at international levels compared with the other groups of subjects (P < 0.001). This statistical difference in horizontal levelness, despite the absence of a noticeable difference in the absolute quantity of inhaled air, may be attributable to the way in which each person inhales and exhales air. Top-level junior swimmers that exhibited a high BB ratio might have inhaled in a way that would counteract the sinking of the lower limbs, for example, through abdominal respiration. When exhaling, on the other hand, they might have let out air gradually to mitigate the acceleration force involved in submerging the lower limbs.

  17. Relative contributions of four exposure pathways to influenza infection risk.

    PubMed

    Nicas, Mark; Jones, Rachael M

    2009-09-01

    The relative contribution of four influenza virus exposure pathways-(1) virus-contaminated hand contact with facial membranes, (2) inhalation of respirable cough particles, (3) inhalation of inspirable cough particles, and (4) spray of cough droplets onto facial membranes-must be quantified to determine the potential efficacy of nonpharmaceutical interventions of transmission. We used a mathematical model to estimate the relative contributions of the four pathways to infection risk in the context of a person attending a bed-ridden family member ill with influenza. Considering the uncertainties in the sparse human subject influenza dose-response data, we assumed alternative ratios of 3,200:1 and 1:1 for the infectivity of inhaled respirable virus to intranasally instilled virus. For the 3,200:1 ratio, pathways (1), (2), and (4) contribute substantially to influenza risk: at a virus saliva concentration of 10(6) mL(-1), pathways (1), (2), (3), and (4) contribute, respectively, 31%, 17%, 0.52%, and 52% of the infection risk. With increasing virus concentrations, pathway (2) increases in importance, while pathway (4) decreases in importance. In contrast, for the 1:1 infectivity ratio, pathway (1) is the most important overall: at a virus saliva concentration of 10(6) mL(-1), pathways (1), (2), (3), and (4) contribute, respectively, 93%, 0.037%, 3.3%, and 3.7% of the infection risk. With increasing virus concentrations, pathway (3) increases in importance, while pathway (4) decreases in importance. Given the sparse knowledge concerning influenza dose and infectivity via different exposure pathways, nonpharmaceutical interventions for influenza should simultaneously address potential exposure via hand contact to the face, inhalation, and droplet spray.

  18. Cyanotoxins in desert environments may present a risk to human health.

    PubMed

    Metcalf, J S; Richer, R; Cox, P A; Codd, G A

    2012-04-01

    There have been few studies concerning cyanotoxins in desert environments, compared with the multitude of studies of cyanotoxins in aquatic environments. However, cyanobacteria are important primary producers in desert environments, where after seasonal rains they can grow rapidly both stabilising and fertilising arid habitats. Samples of cyanobacteria from wadis - dry, ephemeral river beds - and sabkha - supertidal salt flats - in Qatar were analysed for the presence of microcystins, nodularin, anatoxin-a, cylindrospermopsin and anatoxin-a(S). Microcystins were detected by HPLC-PDA and ELISA at concentrations between 1.5 and 53.7ngg(-1) dry wt of crust. PCR products for the mycD gene for microcystin biosynthesis were detected after amplification of DNA from desert crust samples at two out of three sample sites. The presence of anatoxin-a(S) was also indicated by acetylcholine esterase inhibition assay. As a function of area of desert crust, microcystin concentrations were between 3 and 56μgm(-2). Based on the concentration of microcystins detected in crust, with reference to the published inhalation NOAEL and LOAEL values via nasal spray inhalation of purified microcystin-LR in aqueous solution, and the amount of dust potentially inhaled by a person from these dried crusts, the dose of microcystins could exceed a calculated TDI value of 1-2ngkg(-1)day(-1) for an average adult. The presence of microcystins, and potentially of anatoxin-a(S), in desert crusts has important implications for human health. Further studies are required to monitor desert dust storms for the presence of cyanotoxins. An understanding of the risks of inhaling particles containing cyanotoxins is also warranted. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Quantitative risk assessment for a glass fiber insulation product.

    PubMed

    Fayerweather, W E; Bender, J R; Hadley, J G; Eastes, W

    1997-04-01

    California Proposition 65 (Prop65) provides a mechanism by which the manufacturer may perform a quantitative risk assessment to be used in determining the need for cancer warning labels. This paper presents a risk assessment under this regulation for professional and do-it-yourself insulation installers. It determines the level of insulation glass fiber exposure (specifically Owens Corning's R-25 PinkPlus with Miraflex) that, assuming a working lifetime exposure, poses no significant cancer risk under Prop65's regulations. "No significant risk" is defined under Prop65 as a lifetime risk of no more than one additional cancer case per 100,000 exposed persons, and nonsignificant exposure is defined as a working lifetime exposure associated with "no significant risk." This determination can be carried out despite the fact that the relevant underlying studies (i.e., chronic inhalation bioassays) of comparable glass wool fibers do not show tumorigenic activity. Nonsignificant exposures are estimated from (1) the most recent RCC chronic inhalation bioassay of nondurable fiberglass in rats; (2) intraperitoneal fiberglass injection studies in rats; (3) a distributional, decision analysis approach applied to four chronic inhalation rat bioassays of conventional fiberglass; (4) an extrapolation from the RCC chronic rat inhalation bioassay of durable refractory ceramic fibers; and (5) an extrapolation from the IOM chronic rat inhalation bioassay of durable E glass microfibers. When the EPA linear nonthreshold model is used, central estimates of nonsignificant exposure range from 0.36 fibers/cc (for the RCC chronic inhalation bioassay of fiberglass) through 21 fibers/cc (for the i.p. fiberglass injection studies). Lower 95% confidence bounds on these estimates vary from 0.17 fibers/cc through 13 fibers/cc. Estimates derived from the distributional approach or from applying the EPA linear nonthreshold model to chronic bioassays of durable fibers such as refractory ceramic fiber or E glass microfibers are intermediate to the other approaches. Estimates based on the Weibull 1.5-hit nonthreshold and 2-hit threshold models exceed by at least a factor of 10 the corresponding EPA linear nonthreshold estimates. The lowest nonsignificant exposures derived in this assessment are at least a factor of two higher than field exposures measured for professionals installing the R-25 fiberglass insulation product and are orders of magnitude higher than the estimated lifetime exposures for do-it-yourselfers.

  20. Estimation of inhalation flow profile using audio-based methods to assess inhaler medication adherence.

    PubMed

    Taylor, Terence E; Lacalle Muls, Helena; Costello, Richard W; Reilly, Richard B

    2018-01-01

    Asthma and chronic obstructive pulmonary disease (COPD) patients are required to inhale forcefully and deeply to receive medication when using a dry powder inhaler (DPI). There is a clinical need to objectively monitor the inhalation flow profile of DPIs in order to remotely monitor patient inhalation technique. Audio-based methods have been previously employed to accurately estimate flow parameters such as the peak inspiratory flow rate of inhalations, however, these methods required multiple calibration inhalation audio recordings. In this study, an audio-based method is presented that accurately estimates inhalation flow profile using only one calibration inhalation audio recording. Twenty healthy participants were asked to perform 15 inhalations through a placebo Ellipta™ DPI at a range of inspiratory flow rates. Inhalation flow signals were recorded using a pneumotachograph spirometer while inhalation audio signals were recorded simultaneously using the Inhaler Compliance Assessment device attached to the inhaler. The acoustic (amplitude) envelope was estimated from each inhalation audio signal. Using only one recording, linear and power law regression models were employed to determine which model best described the relationship between the inhalation acoustic envelope and flow signal. Each model was then employed to estimate the flow signals of the remaining 14 inhalation audio recordings. This process repeated until each of the 15 recordings were employed to calibrate single models while testing on the remaining 14 recordings. It was observed that power law models generated the highest average flow estimation accuracy across all participants (90.89±0.9% for power law models and 76.63±2.38% for linear models). The method also generated sufficient accuracy in estimating inhalation parameters such as peak inspiratory flow rate and inspiratory capacity within the presence of noise. Estimating inhaler inhalation flow profiles using audio based methods may be clinically beneficial for inhaler technique training and the remote monitoring of patient adherence.

  1. Estimation of inhalation flow profile using audio-based methods to assess inhaler medication adherence

    PubMed Central

    Lacalle Muls, Helena; Costello, Richard W.; Reilly, Richard B.

    2018-01-01

    Asthma and chronic obstructive pulmonary disease (COPD) patients are required to inhale forcefully and deeply to receive medication when using a dry powder inhaler (DPI). There is a clinical need to objectively monitor the inhalation flow profile of DPIs in order to remotely monitor patient inhalation technique. Audio-based methods have been previously employed to accurately estimate flow parameters such as the peak inspiratory flow rate of inhalations, however, these methods required multiple calibration inhalation audio recordings. In this study, an audio-based method is presented that accurately estimates inhalation flow profile using only one calibration inhalation audio recording. Twenty healthy participants were asked to perform 15 inhalations through a placebo Ellipta™ DPI at a range of inspiratory flow rates. Inhalation flow signals were recorded using a pneumotachograph spirometer while inhalation audio signals were recorded simultaneously using the Inhaler Compliance Assessment device attached to the inhaler. The acoustic (amplitude) envelope was estimated from each inhalation audio signal. Using only one recording, linear and power law regression models were employed to determine which model best described the relationship between the inhalation acoustic envelope and flow signal. Each model was then employed to estimate the flow signals of the remaining 14 inhalation audio recordings. This process repeated until each of the 15 recordings were employed to calibrate single models while testing on the remaining 14 recordings. It was observed that power law models generated the highest average flow estimation accuracy across all participants (90.89±0.9% for power law models and 76.63±2.38% for linear models). The method also generated sufficient accuracy in estimating inhalation parameters such as peak inspiratory flow rate and inspiratory capacity within the presence of noise. Estimating inhaler inhalation flow profiles using audio based methods may be clinically beneficial for inhaler technique training and the remote monitoring of patient adherence. PMID:29346430

  2. The inhalation characteristics of patients when they use different dry powder inhalers.

    PubMed

    Azouz, Wahida; Chetcuti, Philip; Hosker, Harold S R; Saralaya, Dinesh; Stephenson, John; Chrystyn, Henry

    2015-02-01

    The characteristics of each inhalation maneuver when patients use dry powder inhalers (DPIs) are important, because they control the quality of the emitted dose. We have measured the inhalation profiles of asthmatic children [CHILD; n=16, mean forced expiratory volume in 1 sec (FEV1) 79% predicted], asthmatic adults (ADULT; n=53, mean predicted FEV1 72%), and chronic obstructive pulmonary disease (COPD; n=29, mean predicted FEV1 42%) patients when they inhaled through an Aerolizer, Diskus, Turbuhaler, and Easyhaler using their "real-life" DPI inhalation technique. These are low-, medium-, medium/high-, and high-resistance DPIs, respectively. The inhalation flow against time was recorded to provide the peak inhalation flow (PIF; in L/min), the maximum pressure change (ΔP; in kPa), acceleration rates (ACCEL; in kPa/sec), time to maximum inhalation, the length of each inhalation (in sec), and the inhalation volume (IV; in liters) of each inhalation maneuver. PIF, ΔP, and ACCEL values were consistent with the order of the inhaler's resistance. For each device, the inhalation characteristics were in the order ADULT>COPD>CHILD for PIF, ΔP, and ACCEL (p<0.001). The results showed a large variability in inhalation characteristics and demonstrate the advantages of ΔP and ACCEL rather than PIFs. Overall inhaled volumes were low, and only one patient achieved an IV >4 L and ΔP >4 kPa. The large variability of these inhalation characteristics and their range highlights that if inhalation profiles were used with compendial in vitro dose emission measurements, then the results would provide useful information about the dose patients inhale during routine use. The inhalation characteristics highlight that adults with asthma have greater inspiratory capacity than patients with COPD, whereas children with asthma have the lowest. The significance of the inhaled volume to empty doses from each device requires investigation.

  3. Automatic multiple-sample applicator and electrophoresis apparatus

    NASA Technical Reports Server (NTRS)

    Grunbaum, B. W. (Inventor)

    1977-01-01

    An apparatus for performing electrophoresis and a multiple-sample applicator is described. Electrophoresis is a physical process in which electrically charged molecules and colloidal particles, upon the application of a dc current, migrate along a gel or a membrane that is wetted with an electrolyte. A multiple-sample applicator is provided which coacts with a novel tank cover to permit an operator either to depress a single button, thus causing multiple samples to be deposited on the gel or on the membrane simultaneously, or to depress one or more sample applicators separately by means of a separate button for each applicator.

  4. Assessment of pediatric Malone antegrade continence enema (MACE) complications: Effects of variations in technique.

    PubMed

    Saikaly, Sami K; Rich, Mark A; Swana, Hubert S

    2016-08-01

    The Malone antegrade continence enema (MACE) procedure is performed for patients with fecal incontinence and constipation who do not respond to medical therapy. The MACE procedure provides antegrade catheter access to the right colon and allows administration of enemas to help evacuate the bowel regularly. The objective of this study was to identify risk factors for surgical complications in children who undergo the MACE procedure. Records from 97 pediatric patients who underwent MACE procedure were reviewed retrospectively. Data collected included age, sex, weight (obese/not obese), stomal location, presence of a permanent button/catheter in the stoma, open vs. laparoscopic surgery, and etiology of fecal incontinence/constipation. The complications reviewed included stomal stenosis, leakage, and stomal site infection. The relationships between the independent variables and complications were assessed using chi-square tests and Fisher's exact test. Statistical significance was set at p < 0.05. Overall, 66 (68%) patients had at least one complication. Twenty-three (23.7%) patients developed stomal stenosis, and 27 (27.8%) patients had significant stomal leakage. Insertion of a stomal button/catheter device was associated with an increased risk of developing stomal leakage and stomal infection. The presence of a stomal button/catheter was also associated with a decreased risk of stomal stenosis (Figure). The non-intubated, imbricated sub-population, preteen patients (<12 years old) experienced more stomal leakage than teenage patients. In this subgroup, patients with umbilical stomas also experienced more leakage than patients with right lower quadrant (RLQ) stomas. The prevalence rates of stomal complications in our study were consistent with previously reported series. In our study, however, stomal leakage had a higher prevalence in comparison with stomal stenosis. This seems to be related to the heterogeneity of the study group, which contained two variants of the MACE procedure; non-imbricated, intubated MACE and imbricated, non-intubated MACE. The use of stomal buttons in conjunction with MACE has previously been reported without changes in complication rates. We found the use of stomal buttons/catheters to be associated with changes in the prevalence of stomal complications. Stomal complications are common in the MACE procedure. The use of a permanent stomal button/catheter is associated with changes in the rates of stomal complications. While many find an umbilical stomal site is more cosmetically appealing, there is an increased risk of leakage with imbricated, non-intubated stomas. In the non-intubated, imbricated sub-population, the MACE procedure results in a higher risk of stomal leakage in preteen patients in comparison with teenage patients. Copyright © 2016 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  5. Inhalation devices: from basic science to practical use, innovative vs generic products.

    PubMed

    Pirozynski, Michal; Sosnowski, Tomasz R

    2016-11-01

    Inhalation therapy is a convenient method of treating respiratory diseases. The key factors required for inhalation are the preparation of drug carriers (aerosol particles) allowing reproducible dosing during administration. These technical challenges are accomplished with a variety of inhalation devices (inhalers) and medicinal formulations, which are optimized to be easily converted into inhalable aerosols. Areas covered: This review is focused on the most important, but often overlooked, effects, which are required for the reliable and reproducible inhalable drug administration. The effects of patient-related issues that influence inhalation therapy, such as proper selection of inhalers for specific cases is discussed. We also discuss factors that are the most essential if generic inhalation product should be considered equivalent to the drugs with the clinically confirmed efficacy. Expert opinion: Proper device selection is crucial in clinical results of inhalation therapy. The patients' ability to coordinate inhalation with actuation, generation of optimal flow through the device, use of optimal inspiratory volume, all produces crucial effects on disease control. Also the severity of the disease process effects proper use of inhalers. Interchanging of inhalers can produce potentially conflicting problem regarding efficacy and safety of inhalation therapy.

  6. Personal exposure to pesticide among workers engaged in pesticide container recycling operations.

    PubMed

    Guidotti, T L; Yoshida, K; Clough, V

    1994-12-01

    Pesticide container handling operations in western Canada were examined to determine the exposure of workers to residual pesticide in sorting, metal-container crushing, metal-container shredding, plastic-container shredding, metal washing, and metal melting. Environmental exposure monitoring and biological monitoring were applied, including measurement of pesticide deposition density on outer clothing (test coveralls and other protective wear), deposition on fabric and gauze patches under the outer clothing, inhalation of airborne pesticide residues, dislodgement of pesticide residues by hand washing, and pre- and postexposure urinary excretion of pesticide (2,4-D). Exposure levels were highly variable; some variability was accounted for by work practices or lapses in protection. The highest levels of exposure were observed for metal washing, metal crushing, and metal shredding; sorting and plastic shredding were intermediate, and metal melting was associated with very little exposure. Urinary 2,4-D excretion, as an indicator of internal dose, correlated most closely with exposure by the inhalation route, and both were highest for metal washing and shredding. Deposition of pesticide on garments was highest for metal crushing. Melting of washed metal does not appear to present a significant hazard of exposure. Recommendations are proposed for the protection of workers emphasizing health and safety guidelines, worker education, personal hygiene, exposure and health monitoring, and record-keeping, and specific recommendations for each process. These recommendations apply to all pesticide container recycling operations except melting of washed metal containers.

  7. Investigation of the 1987 Indianapolis Airport Ramada Inn incident.

    PubMed

    Clark, M A; Hawley, D A; McClain, J L; Pless, J E; Marlin, D C; Standish, S M

    1994-05-01

    On October 20, 1987, a military reserve aircraft lost power during a transcontinental flight and attempted an emergency landing at The Indianapolis International Airport. The pilot ejected and the disabled and pilotless aircraft struck a bank building. It then skidded across the street and entered the lobby of The Airport Ramada Inn where it exploded. This incident was unusual in that the fatal injuries occurred in individuals on the ground and not in the occupant of the aircraft. Seven people were killed in the lobby area and two were trapped in a laundry where they died of smoke inhalation. A tenth person died of burns ten days later. Minor injuries were reported among four hotel guests, two firefighters and the Air Force pilot. A multiagency mass disaster-plan had been formulated and rehearsed in preparation for the Panamerican Games, which had been held in Indianapolis in August 1987. A number of volunteers arrived before a security perimeter was established. They began an undocumented removal of the bodies from the scene and were about to remove valuables for "safekeeping" when stopped by coroners' office personnel. Fatalities resulted from smoke inhalation, burns or a combination. Bodies were identified by a combination of dental records, personal effects and visual means within 24 hours. The problems encountered in managing this disaster scene will also be compared with previously reported incidents.

  8. Effectiveness of Nurse-Driven Inhaler Education on Inhaler Proficiency and Compliance Among Obstructive Lung Disease Patients: A Quasi-Experimental Study.

    PubMed

    Al-Kalaldeh, Mahmoud; El-Rahman, Mona Abd; El-Ata, Amal

    2016-06-01

    Background Health education on proper inhaler usage is the most feasible and accessible strategy to increase inhaler effectiveness. Purpose To assess the impact of nurse-driven inhaler education on the compliance and proficiency of using inhalers among inhaler users. Methods This single-center, quasi-experimental study included the implementation of an individualized 60-min educational session on inhalers use. Health education and pretest and posttest outcomes were assessed by the Inhaler Proficiency Schedule and Patient Reported Behaviour tools. Results One hundred and twenty-one participants joined the study. At pretest, participants showed inadequate knowledge of general inhaler use. No previous training had been received by participants and difficulty with use and complications from using the inhalers were reported. At posttest, participants reported improvement in inhaler proficiency scores from 5.72 to 8.60 ( t = 17.99, df = 220, p < 0.001). Likewise, they showed a significant reduction towards the noncompliant behaviors from 15.21 to 11.19 ( t = 16.388, df = 238, p < 0.001). Conclusions Nurse-driven inhaler education yielded positive outcomes in both inhaler proficiency and compliance. The patients' assessment of using inhalers is crucial to determine the patients' educational deficits.

  9. Checklists for the Assessment of Correct Inhalation Therapy.

    PubMed

    Knipel, V; Schwarz, S; Magnet, F S; Storre, J H; Criée, C P; Windisch, W

    2017-02-01

    Introduction  For the long-term treatment of obstructive lung diseases inhalation therapy with drugs being delivered directly to the lungs as an aerosol has become the method of choice. However, patient-related mistakes in inhalation techniques are frequent and recognized to be associated with reduced disease control. Since the assessment of patient-mistakes in inhalation has yet not been standardized, the present study was aimed at developing checklists for the assessment of correct inhalation. Methods  Checklists were developed in German by an expert panel of pneumologists and professionally translated into English following back-translation procedures. The checklists comparably assessed three major steps of inhalation: 1) inhalation preparation, 2) inhalation routine, and 3) closure of inhalation. Results  Checklists for eight frequently used inhalers were developed: Aerolizer, Breezhaler, Diskus (Accuhaler), metered-dose inhaler, Handihaler, Novolizer, Respimat, Turbohaler. Each checklist consists of ten items: three for inhalation preparation, six for inhalation routine, and one for closure of inhalation. Discussion  Standardized checklists for frequently used inhalers are available in German and English. These checklists can be used for clinical routines or for clinical trials. All checklists can be downloaded free of charge for non-profit application from the homepage of the German Airway League (Deutsche Atemwegsliga e. V.): www.atemwegsliga.de. © Georg Thieme Verlag KG Stuttgart · New York.

  10. Improving communication among nurses and patients.

    PubMed

    Unluturk, Mehmet S; Ozcanhan, Mehmet H; Dalkilic, Gokhan

    2015-07-01

    Patients use nurse call systems to signal nurses for medical help. Traditional push button-flashing lamp call systems are not integrated with other hospital automation systems. Therefore, nurse response time becomes a matter of personal discretion. The improvement obtained by integrating a pager system into the nurse call systems does not increase care efficiency, because unnecessary visits are still not eliminated. To obtain an immediate response and a purposeful visit by a nurse; regardless of the location of nurse in hospital, traditional systems have to be improved by intelligent telephone system integration. The results of the developed Nurse Call System Software (NCSS), the Wireless Phone System Software (WPSS), the Location System Software (LSS) and the communication protocol are provided, together with detailed XML message structures. The benefits of the proposed system are also discussed and the direction of future work is presented. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    This paper reports on an automated metering/proving system for custody transfer of crude oil at the Phillips 66 Co. tanker unloading terminal in Freeport, Texas. It is described as one of the most sophisticated systems developed. The menu-driven, one-button automation removes the proving sequence entirely from manual control. The system also is the to be cost-effective and versatile compared to a dedicated flow computer with API calculation capabilities. Developed by Puffer-Sweiven, systems integrators, the new technology additionally is thought to be the first custody transfer system to employ a programmable logic controller (PLC). The PLC provides the automation, gathers andmore » stores all raw data, and prints alarms. Also the system uses a personal computer operator interface (OI) that runs on the Intel iRMX real time operating system. The OI is loaded with Puffer-Sweiven application software that performs API meter factor and volume correction calculations as well as present color graphics and generate reports.« less

  12. Radiation accident dosimetry on plastics by EPR spectrometry.

    PubMed

    Trompier, F; Bassinet, C; Clairand, I

    2010-02-01

    In case of acute exposure to ionizing radiation, the dose absorbed by the victims has to be rapidly and accurately assessed in order to choose an appropriate medical treatment. Tooth enamel and bone biopsies measured by EPR spectrometry are often used as dose indicators, due to the good radiation sensitivity and the stability of EPR radiation-sensitive signals. Nevertheless, the invasive sampling of teeth and bones limits the application of this technique to retrospective dosimetry. Therefore, we have investigated an alternative non-invasive methodology. We have surveyed with EPR spectrometry the dosimetric properties of the plastics that can be found in personal effects such as glasses (CR-39, polycarbonate), mobile phones (PMMA, polycarbonate), watches and buttons. Dose response, signal stability and effects of storage conditions were investigated. Significant signal fading limits the use for radiation accident dosimetry. Few plastics present the required characteristics to be used in case of a radiation accident.

  13. A randomized controlled trial of nitrous oxide for intrauterine device insertion in nulliparous women.

    PubMed

    Singh, Rameet H; Thaxton, Lauren; Carr, Shannon; Leeman, Lawrence; Schneider, Emily; Espey, Eve

    2016-11-01

    To evaluate the effectiveness of inhaled nitrous oxide for pain management among nulliparous women undergoing intrauterine device (IUD) insertion. A double-blind, randomized controlled trial was conducted among nulliparous women aged 13-45years who underwent IUD insertion at a US center between October 1, 2013, and August 31, 2014. Using a computer-generated randomization sequence, participants were randomly assigned to inhale either oxygen (O 2 ) or a mixture of 50% nitrous oxide and 50% oxygen (N 2 O/O 2 ) through a nasal mask for 2minutes before insertion. Only the person administering the inhalation agent was aware of group assignment. The primary outcome was maximum pain assessed 2minutes after insertion via a 100-mm visual analog scale. Analyses were by intention to treat. Forty women were assigned to each group. Mean maximum pain score at the time of insertion was 54.3±24.8mm for the N 2 O/O 2 group and 55.3±20.9mm for the O 2 group (P=0.86). Adverse effects were reported for 6 (15%) women in the N 2 O/O 2 group and 7 (18%) in the O 2 group (P=0.32). N 2 O/O 2 did not reduce the pain of IUD insertion among nulliparous women. ClinicalTrials.gov: NCT02391714. Published by Elsevier Ireland Ltd.

  14. [Inhaled corticosteroids and growth: should we be worried?].

    PubMed

    Pouessel, G; Gueorguieva, I; Bernaczyk, Y; Flammarion, S; Thumerelle, C; Deschildre, A

    2015-08-01

    Inhaled corticosteroids (ICSs) are the cornerstone and the first stage of asthma treatment. The objective of this study was to synthesize data on the potential effects of ICSs on growth in children. Studies on the short-term impact of ICSs on growth evaluated by knemometry cannot be extrapolated to the medium or long term and therefore have no utility in real life for a given person. In the medium term, the various ICSs given at the usual doses cause a small reduction in growth after 6 months of treatment. This slowdown occurs at the beginning of treatment, especially in younger children, and the growth velocity corrects itself later but without catching up. In the long term, the prolonged use of ICSs seems to induce a small reduction in the final size in adulthood (close to 1cm) occurring in the first 2 years of treatment without worsening over time. The impact of gender, age at onset of treatment, different ICSs, modes of inhalation, and severity of asthma should also be studied further. The benefit of ICSs in asthma treatment is greater than the risk of side effects, including on growth. The majority of the therapeutic effect is obtained for small to moderate doses of ICSs. Regular adjustment of ICS dose for optimal asthma control should also reduce ICS dose and the impact on growth. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  15. Characterization of Total and Size-Fractionated Manganese Exposure by Work Area in a Shipbuilding Yard.

    PubMed

    Jeong, Jee Yeon; Park, Jong Su; Kim, Pan Gyi

    2016-06-01

    Shipbuilding involves intensive welding activities, and welders are exposed to a variety of metal fumes, including manganese, that may be associated with neurological impairments. This study aimed to characterize total and size-fractionated manganese exposure resulting from welding operations in shipbuilding work areas. In this study, we characterized manganese-containing particulates with an emphasis on total mass (n = 86, closed-face 37-mm cassette samplers) and particle size-selective mass concentrations (n = 86, 8-stage cascade impactor samplers), particle size distributions, and a comparison of exposure levels determined using personal cassette and impactor samplers. Our results suggest that 67.4% of all samples were above the current American Conference of Governmental Industrial Hygienists manganese threshold limit value of 100 μg/m(3) as inhalable mass. Furthermore, most of the particles containing manganese in the welding process were of the size of respirable particulates, and 90.7% of all samples exceeded the American Conference of Governmental Industrial Hygienists threshold limit value of 20 μg/m(3) for respirable manganese. The concentrations measured with the two sampler types (cassette: total mass; impactor: inhalable mass) were significantly correlated (r = 0.964, p < 0.001), but the total concentration obtained using cassette samplers was lower than the inhalable concentration of impactor samplers.

  16. Influence of Button mushroom (Agaricus bisporus) on quality and refrigerated storage stability of patties prepared from sutchi catfish (Pangasius hypophthalmus).

    PubMed

    Nayak, Prakash Chandra; Raju, C V; Lakshmisha, I P; Singh, Rajkumar Ratankumar; Sofi, Faisal Rashid

    2015-06-01

    The ability of button mushroom (Agaricus bisporus) in changing physical, chemical, microbial and sensory properties of fish patties prepared from sutchi catfish (Pangasius hypophthalmus) was investigated. Two batches of fresh patties were prepared, one batch was treated with 15 % button mushroom (TP) and other batch was a control (CP) without mushroom. The patties were packed in polythene bags and stored under refrigerated condition (6 ± 2 ºC) without adding any preservatives for the estimation of storage stability. The analyses of patties were conducted at regular intervals of 3 days. The results showed that, Peroxide value, Thiobarbituric acid value, Free fatty acids increased significantly in CP at the end of 12 days whereas the TP was within the acceptable limit up to 16 days. Total volatile base nitrogen and Trimethylamine nitrogen also showed a similar trend. The Total plate count and Aerobic spore formers showed an increasing trend in CP when compared to TP. The sensory scores showed that the overall acceptability of CP were lower than TP, which was acceptable even after 16 days of storage. The present study showed that, the quality and storage stability of TP were observed to be in good condition up to 16 days and started deteriorating 20th day onwards, whereas the CP were acceptable only up to 12 days. Therefore it can be recommended that, addition of 15 % of button mushroom to sutchi catfish patty not only increases the nutritional quality but also increases the shelf life of patties under refrigerated storage.

  17. What Kind of Capsule Endoscope Is Suitable for a Controllable Self-Propelling Capsule Endoscope? Experimental Study Using a Porcine Stomach Model for Clinical Application (with Videos)

    PubMed Central

    Ota, Kazuhiro; Nouda, Sadaharu; Takeuchi, Toshihisa; Iguchi, Munetaka; Kojima, Yuichi; Kuramoto, Takanori; Inoue, Takuya; Shindo, Yasunori; Uesugi, Kenshiro; Fujito, Yoshiaki; Nishihara, Hironori; Ohtsuka, Naotake; Higuchi, Kazuhide

    2015-01-01

    Background We have been developing the Self-Propelling Capsule Endoscope (SPCE) that allows for controllability from outside of the body and real-time observation. What kind of capsule endoscope (CE) is suitable for a controllable SPCE is unclear and a very critical point for clinical application. We compared observing ability of three kinds of SPCEs with different viewing angles and frame rates. Methods Eleven buttons were sewed in an excised porcine stomach. Four examiners controlled the SPCE using PillCamSB2, -ESO2, and -COLON2 (Given Imaging Ltd., Israel), for 10 minutes each with the aim of detecting as many buttons and examining them as closely as possible. The ability to find lesions was assessed based on the number of detected buttons. The SPCE-performance score (SPS) was used to evaluate the ability to examine the lesions in detail. Results The SPCE-ESO2, -COLON2, and -SB2 detected 11 [interquartile range (IQR): 0], 10.5 (IQR, 0.5), and 8 (IQR, 1.0) buttons, respectively. The SPCE-ESO2 and -COLON2 had a significantly better ability to detect lesions than the -SB2 (p < 0.05). The SPCE-ESO2, -COLON2, and -SB2 had significantly different SPS values of 22 (IQR, 0), 16.5 (IQR, 1.5), and 14 (IQR, 1.0), respectively (p < 0.05 for all comparisons; SPCE-SB2 vs. -ESO2, -SB2 vs. -COLON2, and -ESO2 vs. -COLON2). Conclusions PillCamESO2 is most suitable in different three CEs for SPCE for examining lesions in detail of the stomach. PMID:26447694

  18. Limb-kinetic apraxia affects activities of daily living in Parkinson’s disease: a multi-center study

    PubMed Central

    Foki, T.; Vanbellingen, T.; Lungu, C.; Pirker, W.; Bohlhalter, S.; Nyffeler, T.; Kraemmer, J.; Haubenberger, D.; Fischmeister, F. Ph. S.; Auff, E.; Hallett, M.; Beisteiner, R.

    2017-01-01

    Background and purpose Impaired dexterity (fine hand movements) is often present in Parkinson’s disease (PD), even at early to moderate disease stages. It has a detrimental impact on activities of daily living (ADL) such as buttoning, contributing to reduced quality of life. Limb-kinetic apraxia, a loss of the ability to make precise, independent but coordinated finger and hand movements, may contribute to impaired dexterity even more than bradykinesia per se. However, the impact of limb-kinetic apraxia on ADL remains controversial. Our aim was to identify the strongest predictor of buttoning and unbuttoning in PD. It was hypothesized that coin rotation (a surrogate of limb-kinetic apraxia) represents the most important determinant. Methods Sixty-four right-handed, early to moderate PD patients were recruited from three movement disorder centers (Hoehn and Yahr stages 1–3). Buttoning, unbuttoning and coin rotation (right and left hand) represented the target tasks. Motor impairment was assessed according to the Unified Parkinson’s Disease Rating Scale. Results Multiple linear regression analysis showed that coin rotation with the right hand was the only significant predictor of buttoning (P < 0.001) and unbuttoning (P = 0.002). Notably, measures of bradykinesia or overall motor impairment did not represent significant predictors. Conclusions Constituting the novel key finding, limb-kinetic apraxia seems to be particularly relevant for ADL requiring dexterity skills in PD, even at early to moderate disease stages. Our results prompt research into the pathophysiological background and therapeutic options to treat limb-kinetic apraxia. The simple coin rotation test provides valuable information about ADL-related dexterity skills. PMID:27132653

  19. What Kind of Capsule Endoscope Is Suitable for a Controllable Self-Propelling Capsule Endoscope? Experimental Study Using a Porcine Stomach Model for Clinical Application (with Videos).

    PubMed

    Ota, Kazuhiro; Nouda, Sadaharu; Takeuchi, Toshihisa; Iguchi, Munetaka; Kojima, Yuichi; Kuramoto, Takanori; Inoue, Takuya; Shindo, Yasunori; Uesugi, Kenshiro; Fujito, Yoshiaki; Nishihara, Hironori; Ohtsuka, Naotake; Higuchi, Kazuhide

    2015-01-01

    We have been developing the Self-Propelling Capsule Endoscope (SPCE) that allows for controllability from outside of the body and real-time observation. What kind of capsule endoscope (CE) is suitable for a controllable SPCE is unclear and a very critical point for clinical application. We compared observing ability of three kinds of SPCEs with different viewing angles and frame rates. Eleven buttons were sewed in an excised porcine stomach. Four examiners controlled the SPCE using PillCamSB2, -ESO2, and -COLON2 (Given Imaging Ltd., Israel), for 10 minutes each with the aim of detecting as many buttons and examining them as closely as possible. The ability to find lesions was assessed based on the number of detected buttons. The SPCE-performance score (SPS) was used to evaluate the ability to examine the lesions in detail. The SPCE-ESO2, -COLON2, and -SB2 detected 11 [interquartile range (IQR): 0], 10.5 (IQR, 0.5), and 8 (IQR, 1.0) buttons, respectively. The SPCE-ESO2 and -COLON2 had a significantly better ability to detect lesions than the -SB2 (p < 0.05). The SPCE-ESO2, -COLON2, and -SB2 had significantly different SPS values of 22 (IQR, 0), 16.5 (IQR, 1.5), and 14 (IQR, 1.0), respectively (p < 0.05 for all comparisons; SPCE-SB2 vs. -ESO2, -SB2 vs. -COLON2, and -ESO2 vs. -COLON2). PillCamESO2 is most suitable in different three CEs for SPCE for examining lesions in detail of the stomach.

  20. Meal Microstructure Characterization from Sensor-Based Food Intake Detection.

    PubMed

    Doulah, Abul; Farooq, Muhammad; Yang, Xin; Parton, Jason; McCrory, Megan A; Higgins, Janine A; Sazonov, Edward

    2017-01-01

    To avoid the pitfalls of self-reported dietary intake, wearable sensors can be used. Many food ingestion sensors offer the ability to automatically detect food intake using time resolutions that range from 23 ms to 8 min. There is no defined standard time resolution to accurately measure ingestive behavior or a meal microstructure. This paper aims to estimate the time resolution needed to accurately represent the microstructure of meals such as duration of eating episode, the duration of actual ingestion, and number of eating events. Twelve participants wore the automatic ingestion monitor (AIM) and kept a standard diet diary to report their food intake in free-living conditions for 24 h. As a reference, participants were also asked to mark food intake with a push button sampled every 0.1 s. The duration of eating episodes, duration of ingestion, and number of eating events were computed from the food diary, AIM, and the push button resampled at different time resolutions (0.1-30s). ANOVA and multiple comparison tests showed that the duration of eating episodes estimated from the diary differed significantly from that estimated by the AIM and the push button ( p -value <0.001). There were no significant differences in the number of eating events for push button resolutions of 0.1, 1, and 5 s, but there were significant differences in resolutions of 10-30s ( p -value <0.05). The results suggest that the desired time resolution of sensor-based food intake detection should be ≤5 s to accurately detect meal microstructure. Furthermore, the AIM provides more accurate measurement of the eating episode duration than the diet diary.

  1. Meal Microstructure Characterization from Sensor-Based Food Intake Detection

    PubMed Central

    Doulah, Abul; Farooq, Muhammad; Yang, Xin; Parton, Jason; McCrory, Megan A.; Higgins, Janine A.; Sazonov, Edward

    2017-01-01

    To avoid the pitfalls of self-reported dietary intake, wearable sensors can be used. Many food ingestion sensors offer the ability to automatically detect food intake using time resolutions that range from 23 ms to 8 min. There is no defined standard time resolution to accurately measure ingestive behavior or a meal microstructure. This paper aims to estimate the time resolution needed to accurately represent the microstructure of meals such as duration of eating episode, the duration of actual ingestion, and number of eating events. Twelve participants wore the automatic ingestion monitor (AIM) and kept a standard diet diary to report their food intake in free-living conditions for 24 h. As a reference, participants were also asked to mark food intake with a push button sampled every 0.1 s. The duration of eating episodes, duration of ingestion, and number of eating events were computed from the food diary, AIM, and the push button resampled at different time resolutions (0.1–30s). ANOVA and multiple comparison tests showed that the duration of eating episodes estimated from the diary differed significantly from that estimated by the AIM and the push button (p-value <0.001). There were no significant differences in the number of eating events for push button resolutions of 0.1, 1, and 5 s, but there were significant differences in resolutions of 10–30s (p-value <0.05). The results suggest that the desired time resolution of sensor-based food intake detection should be ≤5 s to accurately detect meal microstructure. Furthermore, the AIM provides more accurate measurement of the eating episode duration than the diet diary. PMID:28770206

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fu, Wenkai; Ghosh, Priyarshini; Harrison, Mark

    The performance of traditional Hornyak buttons and two proposed variants for fast-neutron hodoscope applications was evaluated using Geant4. The Hornyak button is a ZnS(Ag)-based device previously deployed at the Idaho National Laboratory's TRansient REActor Test Facility (better known as TREAT) for monitoring fast neutrons emitted during pulsing of fissile fuel samples. Past use of these devices relied on pulse-shape discrimination to reduce the significant levels of background Cherenkov radiation. Proposed are two simple designs that reduce the overall light guide mass (here, polymethyl methacrylate or PMMA), employ silicon photomultipliers (SiPMs), and can be operated using pulse-height discrimination alone to eliminatemore » background noise to acceptable levels. Geant4 was first used to model a traditional Hornyak button, and for assumed, hodoscope-like conditions, an intrinsic efficiency of 0.35% for mono-directional fission neutrons was predicted. The predicted efficiency is in reasonably good agreement with experimental data from the literature and, hence, served to validate the physics models and approximations employed. Geant4 models were then developed to optimize the materials and geometries of two alternatives to the Hornyak button, one based on a homogeneous mixture of ZnS(Ag) and PMMA, and one based on alternating layers of ZnS(Ag) and PMMA oriented perpendicular to the incident neutron beam. For the same radiation environment, optimized, 5-cm long (along the beam path) devices of the homogeneous and layered designs were predicted to have efficiencies of approximately 1.3% and 3.3%, respectively. For longer devices, i.e., lengths larger than 25 cm, these efficiencies were shown to peak at approximately 2.2% and 5.9%, respectively. Furthermore, both designs were shown to discriminate Cherenkov noise intrinsically by using an appropriate pulse-height discriminator level, i.e., pulse-shape discrimination is not needed for these devices.« less

  3. Occupational asthma and contact dermatitis in a spray painter after introduction of an aziridine cross-linker.

    PubMed Central

    Leffler, C T; Milton, D K

    1999-01-01

    A 23-year-old spray painter developed contact dermatitis and respiratory difficulty characterized by small airways obstruction shortly after the polyfunctional aziridine cross-linker CX-100 began to be used in his workplace as a paint activator. The symptoms resolved after he was removed from the workplace and was treated with inhaled and topical steroids. Painters may have an increased risk of asthma due to exposure to a variety of agents, such as isocyanates, alkyd resins, and chromates. This case illustrates the importance of using appropriate work practices and personal protective equipment to minimize exposure. Occupational asthma is diagnosed by a history of work-related symptoms and exposure to known causative agents. The diagnosis is confirmed by serial pulmonary function testing or inhalational challenge testing. The risk of asthma attributable to occupational exposures is probably underappreciated due to underreporting and to inappropriate use of narrow definitions of exposure in epidemiologic studies of attributable risk. Images Figure 1 PMID:10379008

  4. A point-source outbreak of Coccidioidomycosis among a highway construction crew.

    PubMed

    Nicas, Mark

    2018-01-01

    Coccidioidomycosis is an infection caused by inhaling spores of the soil fungus Coccidioides immitis (hereafter termed Cocci). Cocci is endemic in certain areas of California. When soil containing the fungus is disturbed, as during earth-moving activities, respirable Cocci spores can become airborne and be inhaled by persons in the vicinity. This article describes a cluster of seven Cocciodioidomycosis cases among a highway construction crew that occurred in June/July 2008 in Kern County, CA, which is among the most highly endemic regions for Cocci in California. The exposures spanned no more than seven work days, and illness developed within two to three weeks of the exposures. Given the common source of exposure (soil dust generated at the work site) and the multiple cases occurring close in time, the cluster can also be termed a "point-source outbreak." The contractor was not informed of the infection risk and did not take adequate precautions against dust exposure. Appropriate engineering/administrative controls and respiratory protection are discussed.

  5. Evidence for airborne transmission of Norwalk-like virus (NLV) in a hotel restaurant.

    PubMed

    Marks, P J; Vipond, I B; Carlisle, D; Deakin, D; Fey, R E; Caul, E O

    2000-06-01

    An outbreak of gastroenteritis followed a meal in a large hotel during which one of the diners vomited. The clinical features of the illness suggested Norwalk-like virus (NLV, small round structured virus) infection, and this was confirmed by electron microscopy and reverse transcriptase polymerase chain reaction (RT-PCR) of stool samples. Further characterization of the virus by nucleotide sequence analysis of the PCR amplicons revealed identical strains in all the affected individuals. The foods served at the meal could not be demonstrated to be the cause of the outbreak. Analysis of attack rates by dining table showed an inverse relationship with the distance from the person who vomited. No one eating in a separate restaurant reported illness. Transmission from person-to-person or direct contamination of food seems unlikely in this outbreak. However, the findings are consistent with airborne spread of NLV with infection by inhalation with subsequent ingestion of virus particles.

  6. Risk assessment of population inhalation exposure to volatile organic compounds and carbonyls in urban China.

    PubMed

    Du, Zhengjian; Mo, Jinhan; Zhang, Yinping

    2014-12-01

    Over the past three decades, China has experienced rapid urbanization. The risks to its urban population posed by inhalation exposure to hazardous air pollutants (HAPs) have not been well characterized. Here, we summarize recent measurements of 16 highly prevalent HAPs in urban China and compile their distribution inputs. Based on activity patterns of urban Chinese working adults, we derive personal exposures. Using a probabilistic risk assessment method, we determine cancer and non-cancer risks for working females and males. We also assess the uncertainty associated with risk estimates using Monte Carlo simulation, accounting for variations in HAP concentrations, cancer potency factors (CPFs) and inhalation rates. Average total lifetime cancer risks attributable to HAPs are 2.27×10(-4) (2.27 additional cases per 10,000 people exposed) and 2.93×10(-4) for Chinese urban working females and males, respectively. Formaldehyde, 1,4-dichlorobenzene, benzene and 1,3-butadiene are the major risk contributors yielding the highest median cancer risk estimates, >1×10(-5). About 70% of the risk is due to exposures occurring in homes. Outdoor sources contribute most to the risk of benzene, ethylbenzene and carbon tetrachloride, while indoor sources dominate for all other compounds. Chronic exposure limits are not exceeded for non-carcinogenic effects, except for formaldehyde. Risks are overestimated if variation is not accounted for. Sensitivity analyses demonstrate that the major contributors to total variance are range of inhalation rates, CPFs of formaldehyde, 1,4-dichlorobenzene, benzene and 1,3-butadiene, and indoor home concentrations of formaldehyde and benzene. Despite uncertainty, risks exceeding the acceptable benchmark of 1×10(-6) suggest actions to reduce exposures. Future efforts should be directed toward large-scale measurements of air pollutant concentrations, refinement of CPFs and investigation of population exposure parameters. The present study is a first effort to estimate carcinogenic and non-carcinogenic risks of inhalation exposure to HAPs for the large working populations of Chinese cites. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Cellulosic building insulation versus mineral wool, fiberglass or perlite: installer's exposure by inhalation of fibers, dust, endotoxin and fire-retardant additives.

    PubMed

    Breum, N O; Schneider, T; Jørgensen, O; Valdbjørn Rasmussen, T; Skibstrup Eriksen, S

    2003-11-01

    A task-specific exposure matrix was designed for workers installing building insulation materials. A priori, a matrix element was defined by type of task (installer or helper), type of work area (attic spaces or wall cavities) and type of insulation material (slabs from mineral wool, fiberglass or flax; loose-fill cellulosic material or perlite). In the laboratory a mock-up (full scale) of a one-family house was used for simulated installation of insulation materials (four replicates per matrix element). Personal exposure to dust and fibers was measured. The dust was analyzed for content of endotoxin and some trace elements (boron and aluminum) from fire-retardant or mold-resistant additives. Fibers were characterized as WHO fibers or non-WHO fibers. In support of the exposure matrix, the dustiness of all the materials was measured in a rotating drum tester. For installers in attic spaces, risk of exposure was low for inhalation of dust and WHO fibers from slab materials of mineral wool or fiberglass. Slab materials from flax may cause high risk of exposure to endotoxin. The risk of exposure by inhalation of dust from loose-fill materials was high for installers in attic spaces and for some of the materials risk of exposure was high for boron and aluminum. Exposure by inhalation of cellulosic WHO fibers was high but little is known about the health effects and a risk assessment is not possible. For the insulation of walls, the risk of installers' exposure by inhalation of dust and fibers was low for the slab materials, while a high risk was observed for loose-fill materials. The exposure to WHO fibers was positively correlated to the dust exposure. A dust level of 6.1 mg/m3 was shown to be useful as a proxy for screening exposure to WHO fibers in excess of 10(6) fibers/m3. In the rotating drum, slabs of insulation material from mineral wool or fiberglass were tested as not dusty. Cellulosic loose-fill materials were tested as very dusty, and perlite proved to be extremely dusty.

  8. Individual differences in first- and second-order temporal judgment.

    PubMed

    Corcoran, Andrew W; Groot, Christopher; Bruno, Aurelio; Johnston, Alan; Cropper, Simon J

    2018-01-01

    The ability of subjects to identify and reproduce brief temporal intervals is influenced by many factors whether they be stimulus-based, task-based or subject-based. The current study examines the role individual differences play in subsecond and suprasecond timing judgments, using the schizoptypy personality scale as a test-case approach for quantifying a broad range of individual differences. In two experiments, 129 (Experiment 1) and 141 (Experiment 2) subjects completed the O-LIFE personality questionnaire prior to performing a modified temporal-bisection task. In the bisection task, subjects responded to two identical instantiations of a luminance grating presented in a 4deg window, 4deg above fixation for 1.5 s (Experiment 1) or 3 s (Experiment 2). Subjects initiated presentation with a button-press, and released the button when they considered the stimulus to be half-way through (750/1500 ms). Subjects were then asked to indicate their 'most accurate estimate' of the two intervals. In this way we measure both performance on the task (a first-order measure) and the subjects' knowledge of their performance (a second-order measure). In Experiment 1 the effect of grating-drift and feedback on performance was also examined. Experiment 2 focused on the static/no-feedback condition. For the group data, Experiment 1 showed a significant effect of presentation order in the baseline condition (no feedback), which disappeared when feedback was provided. Moving the stimulus had no effect on perceived duration. Experiment 2 showed no effect of stimulus presentation order. This elimination of the subsecond order-effect was at the expense of accuracy, as the mid-point of the suprasecond interval was generally underestimated. Response precision increased as a proportion of total duration, reducing the variance below that predicted by Weber's law. This result is consistent with a breakdown of the scalar properties of time perception in the early suprasecond range. All subjects showed good insight into their own performance, though that insight did not necessarily correlate with the veridical bisection point. In terms of personality, we found evidence of significant differences in performance along the Unusual Experiences subscale, of most theoretical interest here, in the subsecond condition only. There was also significant correlation with Impulsive Nonconformity and Cognitive Disorganisation in the sub- and suprasecond conditions, respectively. Overall, these data support a partial dissociation of timing mechanisms at very short and slightly longer intervals. Further, these results suggest that perception is not the only critical mitigator of confidence in temporal experience, since individuals can effectively compensate for differences in perception at the level of metacognition in early suprasecond time. Though there are individual differences in performance, these are perhaps less than expected from previous reports and indicate an effective timing mechanism dealing with brief durations independent of the influence of significant personality trait differences.

  9. Practical aspects of inhaler use in the management of chronic obstructive pulmonary disease in the primary care setting.

    PubMed

    Yawn, Barbara P; Colice, Gene L; Hodder, Rick

    2012-01-01

    Sustained bronchodilation using inhaled medications in moderate to severe chronic obstructive pulmonary disease (COPD) grades 2 and 3 (Global Initiative for Chronic Obstructive Lung Disease guidelines) has been shown to have clinical benefits on long-term symptom control and quality of life, with possible additional benefits on disease progression and longevity. Aggressive diagnosis and treatment of symptomatic COPD is an integral and pivotal part of COPD management, which usually begins with primary care physicians. The current standard of care involves the use of one or more inhaled bronchodilators, and depending on COPD severity and phenotype, inhaled corticosteroids. There is a wide range of inhaler devices available for delivery of inhaled medications, but suboptimal inhaler use is a common problem that can limit the clinical effectiveness of inhaled therapies in the real-world setting. Patients' comorbidities, other physical or mental limitations, and the level of inhaler technique instruction may limit proper inhaler use. This paper presents information that can overcome barriers to proper inhaler use, including issues in device selection, steps in correct technique for various inhaler devices, and suggestions for assessing and monitoring inhaler techniques. Ensuring proper inhaler technique can maximize drug effectiveness and aid clinical management at all grades of COPD.

  10. Practical aspects of inhaler use in the management of chronic obstructive pulmonary disease in the primary care setting

    PubMed Central

    Yawn, Barbara P; Colice, Gene L; Hodder, Rick

    2012-01-01

    Sustained bronchodilation using inhaled medications in moderate to severe chronic obstructive pulmonary disease (COPD) grades 2 and 3 (Global Initiative for Chronic Obstructive Lung Disease guidelines) has been shown to have clinical benefits on long-term symptom control and quality of life, with possible additional benefits on disease progression and longevity. Aggressive diagnosis and treatment of symptomatic COPD is an integral and pivotal part of COPD management, which usually begins with primary care physicians. The current standard of care involves the use of one or more inhaled bronchodilators, and depending on COPD severity and phenotype, inhaled corticosteroids. There is a wide range of inhaler devices available for delivery of inhaled medications, but suboptimal inhaler use is a common problem that can limit the clinical effectiveness of inhaled therapies in the real-world setting. Patients’ comorbidities, other physical or mental limitations, and the level of inhaler technique instruction may limit proper inhaler use. This paper presents information that can overcome barriers to proper inhaler use, including issues in device selection, steps in correct technique for various inhaler devices, and suggestions for assessing and monitoring inhaler techniques. Ensuring proper inhaler technique can maximize drug effectiveness and aid clinical management at all grades of COPD. PMID:22888221

  11. SITE SPECIFIC REFERENCE PERSON PARAMETERS AND DERIVED CONCENTRATION STANDARDS FOR THE SAVANNAH RIVER SITE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jannik, T.

    2013-03-14

    The purpose of this report is twofold. The first is to develop a set of behavioral parameters for a reference person specific for the Savannah River Site (SRS) such that the parameters can be used to determine dose to members of the public in compliance with Department of Energy (DOE) Order 458.1 “Radiation Protection of the Public and the Environment.” A reference person is a hypothetical, gender and age aggregation of human physical and physiological characteristics arrived at by international consensus for the purpose of standardizing radiation dose calculations. DOE O 458.1 states that compliance with the annual dose limitmore » of 100 mrem (1 mSv) to a member of the public may be demonstrated by calculating the dose to the maximally exposed individual (MEI) or to a representative person. Historically, for dose compliance, SRS has used the MEI concept, which uses adult dose coefficients and adult male usage parameters. Beginning with the 2012 annual site environmental report, SRS will be using the representative person concept for dose compliance. The dose to a representative person will be based on 1) the SRS-specific reference person usage parameters at the 95th percentile of appropriate national or regional data, which are documented in this report, 2) the reference person (gender and age averaged) ingestion and inhalation dose coefficients provided in DOE Derived Concentration Technical Standard (DOE-STD-1196-2011), and 3) the external dose coefficients provided in the DC_PAK3 toolbox. The second purpose of this report is to develop SRS-specific derived concentration standards (DCSs) for all applicable food ingestion pathways, ground shine, and water submersion. The DCS is the concentration of a particular radionuclide in water, in air, or on the ground that results in a member of the public receiving 100 mrem (1 mSv) effective dose following continuous exposure for one year. In DOE-STD-1196-2011, DCSs were developed for the ingestion of water, inhalation of air and submersion in air pathways, only. These DCSs are required by DOE O 458.1 to be used at all DOE sites in the design and conduct of radiological environmental protection programs. In this report, DCSs for the following additional pathways were considered and documented: ingestion of meat, dairy, grains, produce (fruits and vegetables), seafood, submersion in water and ground shine. These additional DCSs were developed using the same methods as in DOE-STD-1196-2011 and will be used at SRS, where appropriate, as screening and reference values.« less

  12. Internal dose assessment of 210Po using biokinetic modeling and urinary excretion measurement.

    PubMed

    Li, Wei Bo; Gerstmann, Udo; Giussani, Augusto; Oeh, Uwe; Paretzke, Herwig G

    2008-02-01

    The mysterious death of Mr. Alexander Litvinenko who was most possibly poisoned by Polonium-210 ((210)Po) in November 2006 in London attracted the attention of the public to the kinetics, dosimetry and the risk of this high radiotoxic isotope in the human body. In the present paper, the urinary excretion of seven persons who were possibly exposed to traces of (210)Po was monitored. The values measured in the GSF Radioanalytical Laboratory are in the range of natural background concentration. To assess the effective dose received by those persons, the time-dependence of the organ equivalent dose and the effective dose after acute ingestion and inhalation of (210)Po were calculated using the biokinetic model for polonium (Po) recommended by the International Commission on Radiological Protection (ICRP) and the one recently published by Leggett and Eckerman (L&E). The daily urinary excretion to effective dose conversion factors for ingestion and inhalation were evaluated based on the ICRP and L&E models for members of the public. The ingestion (inhalation) effective dose per unit intake integrated over one day is 1.7 x 10(-8) (1.4 x 10(-7)) Sv Bq(-1), 2.0 x 10(-7) (9.6 x 10(-7)) Sv Bq(-1) over 10 days, 5.2 x 10(-7) (2.0 x 10(-6)) Sv Bq(-1) over 30 days and 1.0 x 10(-6) (3.0 x 10(-6)) Sv Bq(-1) over 100 days. The daily urinary excretions after acute ingestion (inhalation) of 1 Bq of (210)Po are 1.1 x 10(-3) (1.0 x 10(-4)) on day 1, 2.0 x 10(-3) (1.9 x 10(-4)) on day 10, 1.3 x 10(-3) (1.7 x 10(-4)) on day 30 and 3.6 x 10(-4) (8.3 x 10(-5)) Bq d(-1) on day 100, respectively. The resulting committed effective doses range from 2.1 x 10(-3) to 1.7 x 10(-2) mSv by an assumption of ingestion and from 5.5 x 10(-2) to 4.5 x 10(-1) mSv by inhalation. For the case of Mr. Litvinenko, the mean organ absorbed dose as a function of time was calculated using both the above stated models. The red bone marrow, the kidneys and the liver were considered as the critical organs. Assuming a value of lethal absorbed dose of 5 Gy to the bone marrow, 6 Gy to the kidneys and 8 Gy to the liver, the amount of (210)Po which Mr. Litvinenko might have ingested is therefore estimated to range from 27 to 1,408 MBq, i.e 0.2-8.5 microg, depending on the modality of intake and on different assumptions about blood absorption.

  13. Teaching inhaler use in chronic obstructive pulmonary disease patients.

    PubMed

    Lareau, Suzanne C; Hodder, Richard

    2012-02-01

    To review barriers to the successful use of inhalers in patients with chronic obstructive pulmonary disease (COPD), and the role of the nurse practitioner (NP) in facilitating optimum inhaler use. Review of the national and international scientific literature. Pharmacologic treatment of COPD patients comprises mainly inhaled medications. Incorrect use of inhalers is very common in these individuals. Some of the consequences of poor inhaler technique include reduced therapeutic dosing, medication adherence, and disease stability, which can lead to increased morbidity, decreased quality of life, and a high burden on the healthcare system. Knowledgeable evaluation and frequent reassessment of inhaler use coupled with education of patients, caregivers, and healthcare professionals can significantly improve the benefits COPD patients derive from inhaled therapy. Patient education is vital for correct use of inhalers and to ensure the effectiveness of inhaled medications. The NP has a critical role in assessing potential barriers to successful learning by the patient and improving inhaler technique and medication management. The NP can also facilitate success with inhaled medications by providing up-to-date inhaler education for other healthcare team members, who may then act as patient educators. ©2011 The Author(s) Journal compilation ©2011 American Academy of Nurse Practitioners.

  14. Inhaled Asthma Medications

    MedlinePlus

    ... metered – dose inhaler (MDI), which uses a chemical propellant to push the medication out of the inhaler. ... powder inhalers (DPIs) deliver medication without using chemical propellants, but they require a strong and fast inhalation. ...

  15. Personality scores and smoking behaviour. A longitudinal study.

    PubMed Central

    Cherry, N; Kiernan, K

    1976-01-01

    The personality scores at 16 years of age of 2753 people, all members of the National Survey of Health and Development, were related, in a follow-up study, to cigarette smoking behaviour in their young adult years. Survey members who recorded high neuroticism scores were found to be more likely to smoke than those with low scores and, among the smokers, deep inhalers formed the most neurotic group. Extraverts were more likely to smoke than introverts, the mean extraversion score being greatest for the male smokers with a high daily consumption of cigarettes. The personality scores were found to have some power in predicting changes in smoking behaviour. Neurotics and extraverts who had not started to smoke by the time of completing the personality inventory at 16 were more likely than the stable and introverted to take up the habit subsequently. Among survey members who were regular smokers at the time of completing the personality inventory the proportion giving up smoking by the time they reached the age of 25 years was related to consumption level recorded at 20 years and the personality scores recorded at 16, stable extraverts among the men being most likely to stop smoking. PMID:953376

  16. METEOSAT studies of clouds and radiation budget

    NASA Technical Reports Server (NTRS)

    Saunders, R. W.

    1982-01-01

    Radiation budget studies of the atmosphere/surface system from Meteosat, cloud parameter determination from space, and sea surface temperature measurements from TIROS N data are all described. This work was carried out on the interactive planetary image processing system (IPIPS), which allows interactive manipulationion of the image data in addition to the conventional computational tasks. The current hardware configuration of IPIPS is shown. The I(2)S is the principal interactive display allowing interaction via a trackball, four buttons under program control, or a touch tablet. Simple image processing operations such as contrast enhancing, pseudocoloring, histogram equalization, and multispectral combinations, can all be executed at the push of a button.

  17. 20 mm lithium button battery causing an oesophageal perforation in a toddler: lessons in diagnosis and treatment.

    PubMed

    Soccorso, Giampiero; Grossman, Ole; Martinelli, Massimo; Marven, Sean S; Patel, Kirtik; Thomson, Mike; Roberts, Julian P

    2012-08-01

    Swallowed button batteries (BB) which remain lodged in the oesophagus are at risk of serious complications, particularly in young children. The authors report a 3-year-old child, who rapidly developed an oesophageal perforation, following the ingestion of a 20-mm lithium BB which was initially mistaken for a coin. A thoracotomy and T-tube management of the perforation led to a positive outcome. BBs (20 mm) in children should be removed quickly and close observation is required as the damage initiated by the battery can lead to a significant injury within a few hours.

  18. Hiroshima neutron fluence on a glass button from near ground zero.

    PubMed

    Fleischer, R L; Fujita, S; Hoshi, M

    2001-12-01

    A decorative glass button that was uncovered at a location that is 190 +/- 15 m from directly beneath the atomic explosion at Hiroshima on 6 August 1945 has been scanned for induced fission tracks produced mostly by the thermal neutrons from the bomb due to interactions with the trace uranium that is normally present in silicate glasses. In surveying 4.14 cm2 at 500x magnification, 28 tracks were seen. From a calibration irradiation in a nuclear reactor we infer that the neutron fluence in 1945 was 5.7(+/-1.1) x 10(11) cm(-2); and, allowing for shielding by the structure in which the button was probably located, the free-air (i.e., outside) value is estimated as 1.5(+/-0.5) x 10(12) cm(-2). A limit has been placed on possible fading of the radiation-damage tracks that could increase the fluence by at most a factor of 1.27. The values bracket the calculated value of 9 x 10(11) given in DS86 but are higher than the 3.6 x 10(11) inferred from induced radionuclides for the distance given. The difference is, however, within the observed variability of the two types of results.

  19. Toward virtual anatomy: a stereoscopic 3-D interactive multimedia computer program for cranial osteology.

    PubMed

    Trelease, R B

    1996-01-01

    Advances in computer visualization and user interface technologies have enabled development of "virtual reality" programs that allow users to perceive and to interact with objects in artificial three-dimensional environments. Such technologies were used to create an image database and program for studying the human skull, a specimen that has become increasingly expensive and scarce. Stereoscopic image pairs of a museum-quality skull were digitized from multiple views. For each view, the stereo pairs were interlaced into a single, field-sequential stereoscopic picture using an image processing program. The resulting interlaced image files are organized in an interactive multimedia program. At run-time, gray-scale 3-D images are displayed on a large-screen computer monitor and observed through liquid-crystal shutter goggles. Users can then control the program and change views with a mouse and cursor to point-and-click on screen-level control words ("buttons"). For each view of the skull, an ID control button can be used to overlay pointers and captions for important structures. Pointing and clicking on "hidden buttons" overlying certain structures triggers digitized audio spoken word descriptions or mini lectures.

  20. Influence of productivity and processing method on physicochemical characteristics of white button mushrooms in Brazil.

    PubMed

    Zied, Diego Cunha; Penachio, Sara Maciel; Dias, Eustáquio Souza; de Almeida Minhoni, Marli Teixeira; Ferraz, Rafael Augusto; Vieites, Rogério Lopes

    2014-11-01

    The white button mushroom is the edible fungus most commonly cultivated and commercialized in Brazil and worldwide. This work assesses the productivity of the different strains ABI 07/06 and ABI 06/05 of Agaricus bisporus grown under the conditions normally employed by growers in the southeast of Brazil, and the influence of four different chemical conservation methods on the physicochemical characteristics and storage properties of the fruit bodies. The productivities of strains ABI 07/06 and ABI 06/05 of white button mushrooms were found to be comparable. The colorimetric characteristics and chemical compositions (fat, fiber and protein contents) of the mushroom strains were similar, and these parameters were not influenced significantly by the conservation processes. Texture was negatively affected by all processing methods employed. It was concluded that chemical methods of processing mushrooms were not fully effective and novel alternative technologies should be considered by mushroom processors in Brazil. Some methods of mushroom storage using chemicals such as sodium metabisulfite are harmful to the human organism, so processing using autoclaving may be the best form of conservation of canned mushrooms. © 2014 Society of Chemical Industry.

  1. Dual-Band Dual-Mode Button Antenna for On-Body and Off-Body Communications.

    PubMed

    Zhang, Xiu Yin; Wong, Hang; Mo, Te; Cao, Yun Fei

    2017-08-01

    A dual-band dual-mode button antenna for body centric communications is presented. At the lower band, a spiral inverted-F antenna is designed with omnidirectional radiation pattern for on-body communication. At the upper band, the high-order mode of the inverted-F antenna is utilized together with a metal reflector to realize broadside radiation for off-body communication. For demonstration, a prototype is implemented. The measured peak gains on the phantom at the lower and upper bands are -0.6 and 4.3 dBi, respectively. The antenna operating on the phantom has measured efficiencies of 46.3% at the lower band and 69.3% at the upper band. The issue of specific absorption rate (SAR) is studied. The maximum transmitted power under the SAR regulation of 1.6 W/kg is found to be 26.4 dB·m, which is high enough for body centric communications. In addition, the transmission performance between two proposed antennas mounted on the body is investigated by measuring the transmission loss. With an overall miniaturized size, the robust button antenna could be integrated in clothes and be a potential candidate for wireless body area network applications.

  2. World Wide Web Metaphors for Search Mission Data

    NASA Technical Reports Server (NTRS)

    Norris, Jeffrey S.; Wallick, Michael N.; Joswig, Joseph C.; Powell, Mark W.; Torres, Recaredo J.; Mittman, David S.; Abramyan, Lucy; Crockett, Thomas M.; Shams, Khawaja S.; Fox, Jason M.; hide

    2010-01-01

    A software program that searches and browses mission data emulates a Web browser, containing standard meta - phors for Web browsing. By taking advantage of back-end URLs, users may save and share search states. Also, since a Web interface is familiar to users, training time is reduced. Familiar back and forward buttons move through a local search history. A refresh/reload button regenerates a query, and loads in any new data. URLs can be constructed to save search results. Adding context to the current search is also handled through a familiar Web metaphor. The query is constructed by clicking on hyperlinks that represent new components to the search query. The selection of a link appears to the user as a page change; the choice of links changes to represent the updated search and the results are filtered by the new criteria. Selecting a navigation link changes the current query and also the URL that is associated with it. The back button can be used to return to the previous search state. This software is part of the MSLICE release, which was written in Java. It will run on any current Windows, Macintosh, or Linux system.

  3. Haptic Stylus and Empirical Studies on Braille, Button, and Texture Display

    PubMed Central

    Kyung, Ki-Uk; Lee, Jun-Young; Park, Junseok

    2008-01-01

    This paper presents a haptic stylus interface with a built-in compact tactile display module and an impact module as well as empirical studies on Braille, button, and texture display. We describe preliminary evaluations verifying the tactile display's performance indicating that it can satisfactorily represent Braille numbers for both the normal and the blind. In order to prove haptic feedback capability of the stylus, an experiment providing impact feedback mimicking the click of a button has been conducted. Since the developed device is small enough to be attached to a force feedback device, its applicability to combined force and tactile feedback display in a pen-held haptic device is also investigated. The handle of pen-held haptic interface was replaced by the pen-like interface to add tactile feedback capability to the device. Since the system provides combination of force, tactile and impact feedback, three haptic representation methods for texture display have been compared on surface with 3 texture groups which differ in direction, groove width, and shape. In addition, we evaluate its capacity to support touch screen operations by providing tactile sensations when a user rubs against an image displayed on a monitor. PMID:18317520

  4. Haptic stylus and empirical studies on braille, button, and texture display.

    PubMed

    Kyung, Ki-Uk; Lee, Jun-Young; Park, Junseok

    2008-01-01

    This paper presents a haptic stylus interface with a built-in compact tactile display module and an impact module as well as empirical studies on Braille, button, and texture display. We describe preliminary evaluations verifying the tactile display's performance indicating that it can satisfactorily represent Braille numbers for both the normal and the blind. In order to prove haptic feedback capability of the stylus, an experiment providing impact feedback mimicking the click of a button has been conducted. Since the developed device is small enough to be attached to a force feedback device, its applicability to combined force and tactile feedback display in a pen-held haptic device is also investigated. The handle of pen-held haptic interface was replaced by the pen-like interface to add tactile feedback capability to the device. Since the system provides combination of force, tactile and impact feedback, three haptic representation methods for texture display have been compared on surface with 3 texture groups which differ in direction, groove width, and shape. In addition, we evaluate its capacity to support touch screen operations by providing tactile sensations when a user rubs against an image displayed on a monitor.

  5. Voluntary and Involuntary Movements Widen the Window of Subjective Simultaneity.

    PubMed

    Arikan, B Ezgi; van Kemenade, Bianca M; Straube, Benjamin; Harris, Laurence R; Kircher, Tilo

    2017-01-01

    Forming a coherent percept of an event requires different sensory inputs originating from the event to be bound. Perceiving synchrony aids in binding of these inputs. In two experiments, we investigated how voluntary movements influence the perception of simultaneity, by measuring simultaneity judgments (SJs) for an audiovisual (AV) stimulus pair triggered by a voluntary button press. In Experiment 1, we manipulated contiguity between the action and its consequences by introducing delays between the button press and the AV stimulus pair. We found a widened window of subjective simultaneity (WSS) when the action-feedback relationship was time contiguous. Introducing a delay narrowed the WSS, suggesting that the wider WSS around the time of an action might facilitate perception of simultaneity. In Experiment 2, we introduced an involuntary condition using an externally controlled button to assess the influence of action-related predictive processes on SJs. We found a widened WSS around the action time, regardless of movement type, supporting the influence of causal relations in the perception of synchrony. Interestingly, the slopes of the psychometric functions in the voluntary condition were significantly steeper than the slopes in the involuntary condition, suggesting a role of action-related predictive mechanisms in making SJs more precise.

  6. Voluntary and Involuntary Movements Widen the Window of Subjective Simultaneity

    PubMed Central

    Arikan, B. Ezgi; van Kemenade, Bianca M.; Straube, Benjamin; Harris, Laurence R.; Kircher, Tilo

    2017-01-01

    Forming a coherent percept of an event requires different sensory inputs originating from the event to be bound. Perceiving synchrony aids in binding of these inputs. In two experiments, we investigated how voluntary movements influence the perception of simultaneity, by measuring simultaneity judgments (SJs) for an audiovisual (AV) stimulus pair triggered by a voluntary button press. In Experiment 1, we manipulated contiguity between the action and its consequences by introducing delays between the button press and the AV stimulus pair. We found a widened window of subjective simultaneity (WSS) when the action-feedback relationship was time contiguous. Introducing a delay narrowed the WSS, suggesting that the wider WSS around the time of an action might facilitate perception of simultaneity. In Experiment 2, we introduced an involuntary condition using an externally controlled button to assess the influence of action-related predictive processes on SJs. We found a widened WSS around the action time, regardless of movement type, supporting the influence of causal relations in the perception of synchrony. Interestingly, the slopes of the psychometric functions in the voluntary condition were significantly steeper than the slopes in the involuntary condition, suggesting a role of action-related predictive mechanisms in making SJs more precise. PMID:28835813

  7. Accuracy assessment of land surface temperature retrievals from Landsat 7 ETM + in the Dry Valleys of Antarctica using iButton temperature loggers and weather station data.

    PubMed

    Brabyn, Lars; Zawar-Reza, Peyman; Stichbury, Glen; Cary, Craig; Storey, Bryan; Laughlin, Daniel C; Katurji, Marwan

    2014-04-01

    The McMurdo Dry Valleys of Antarctica are the largest snow/ice-free regions on this vast continent, comprising 1% of the land mass. Due to harsh environmental conditions, the valleys are bereft of any vegetation. Land surface temperature is a key determinate of microclimate and a driver for sensible and latent heat fluxes of the surface. The Dry Valleys have been the focus of ecological studies as they arguably provide the simplest trophic structure suitable for modelling. In this paper, we employ a validation method for land surface temperatures obtained from Landsat 7 ETM + imagery and compared with in situ land surface temperature data collected from four transects totalling 45 iButtons. A single meteorological station was used to obtain a better understanding of daily and seasonal cycles in land surface temperatures. Results show a good agreement between the iButton and the Landsat 7 ETM + product for clear sky cases. We conclude that Landsat 7 ETM + derived land surface temperatures can be used at broad spatial scales for ecological and meteorological research.

  8. Development and Testing of a Novel Standard Particle for Performance Verification of Biodefense/Bioterrorism Detection Systems

    DTIC Science & Technology

    2003-11-19

    Higher boiling point (29.4o F) 39.5 1.36 1,1- difluoroethane HFA 152a – Not used for pharmaceutical inhalers , is used for personal products Boiling...technologies have been implemented. One aspect of this rapid development that has kept biodetection Page 1 Report Documentation Page Form...ApprovedOMB No. 0704-0188 Public reporting burden for the collection of information is estimated to average 1 hour per response, including the time for

  9. Poppers: large cancer increase and immune suppression in animal tests.

    PubMed

    James, J S

    1999-04-16

    A study on mice injected with cancer cells and then exposed to isobutyl nitrite (poppers) revealed that inhalant-treated mice developed tumors more readily and rapidly than control mice. The control mice were also injected with cancer cells, but only breathed air. Related studies found that poppers suppress certain immune functions involved in killing tumor cells. These studies suggest that further research of persons with HIV/AIDS who use poppers is needed to determine if they are at a high risk for developing malignancies.

  10. A chlorate candle/lithium hydroxide personal breathing apparatus

    NASA Technical Reports Server (NTRS)

    Martin, F. E.

    1972-01-01

    A portable coal mine rescue and survival equipment is reported that consists of a chlorate candle with a lithium hydroxide carbon-dioxide absorbent for oxygen generation, a breathing bag and tubing to conduct breathing to and from the man. A plastic hood incorporating a mouth piece for communication provides also eye protection and prevents inhalation through the nose. Manned testing of a prototype system demonstrated the feasibility of this closed circuit no-maintenance breathing apparatus that provides for good voice communication.

  11. Sulfur Mustard- and Phosgene- Increased IL-8 in Human Small Airway Cell Cultures: Implications for Medical Countermeasures Against Inhalation Toxicity

    DTIC Science & Technology

    2005-10-01

    TOXICITY Fred M. Cowan, William J . Smith, Ted S. Moran, Michelle M. Parris, Adetunji B. Williams and Alfred M. Sciuto U.S. Army Medical Research...toxicity in rodents (reviewed, 5) and some efficacy in the MEVM (personal communication, Dr. William J . Smith, USAMRICD, APG Md). Ibuprofen (62, 125...and inflammatory response in the toxicity of nerve and blister chemical warfare agents: implications for multi-threat medical countermeasures. J

  12. Inhalant Use and Inhalant Use Disorders in the United States

    PubMed Central

    Howard, Matthew O.; Bowen, Scott E.; Garland, Eric L.; Perron, Brian E.; Vaughn, Michael G.

    2011-01-01

    More than 22 million Americans age 12 and older have used inhalants, and every year more than 750,000 use inhalants for the first time. Despite the substantial prevalence and serious toxicities of inhalant use, it has been termed “the forgotten epidemic.” Inhalant abuse remains the least-studied form of substance abuse, although research on its epidemiology, neurobiology, treatment, and prevention has accelerated in recent years. This review examines current findings in these areas, identifies gaps in the research and clinical literatures pertaining to inhalant use, and discusses future directions for inhalant-related research and practice efforts. PMID:22003419

  13. Assessment of inhalation exposures and potential health risks to the general population that resulted from the collapse of the World Trade Center towers.

    PubMed

    Lorber, Matthew; Gibb, Herman; Grant, Lester; Pinto, Joseph; Pleil, Joachim; Cleverly, David

    2007-10-01

    In the days following the collapse of the World Trade Center (WTC) towers on September 11, 2001 (9/11), the U.S. Environmental Protection Agency (EPA) initiated numerous air monitoring activities to better understand the ongoing impact of emissions from that disaster. Using these data, EPA conducted an inhalation exposure and human health risk assessment to the general population. This assessment does not address exposures and potential impacts that could have occurred to rescue workers, firefighters, and other site workers, nor does it address exposures that could have occurred in the indoor environment. Contaminants evaluated include particulate matter (PM), metals, polychlorinated biphenyls, dioxins, asbestos, volatile organic compounds, particle-bound polycyclic aromatic hydrocarbons, silica, and synthetic vitreous fibers (SVFs). This evaluation yielded three principal findings. (1) Persons exposed to extremely high levels of ambient PM and its components, SVFs, and other contaminants during the collapse of the WTC towers, and for several hours afterward, were likely to be at risk for acute and potentially chronic respiratory effects. (2) Available data suggest that contaminant concentrations within and near ground zero (GZ) remained significantly elevated above background levels for a few days after 9/11. Because only limited data on these critical few days were available, exposures and potential health impacts could not be evaluated with certainty for this time period. (3) Except for inhalation exposures that may have occurred on 9/11 and a few days afterward, the ambient air concentration data suggest that persons in the general population were unlikely to suffer short-term or long-term adverse health effects caused by inhalation exposures. While this analysis by EPA evaluated the potential for health impacts based on measured air concentrations, epidemiological studies conducted by organizations other than EPA have attempted to identify actual impacts. Such studies have identified respiratory effects in worker and general populations, and developmental effects in newborns whose mothers were near GZ on 9/11 or shortly thereafter. While researchers are not able to identify specific times and even exactly which contaminants are the cause of these effects, they have nonetheless concluded that exposure to WTC contaminants (and/or maternal stress, in the case of developmental effects) resulted in these effects, and have identified the time period including 9/11 itself and the days and few weeks afterward as a period of most concern based on high concentrations of key pollutants in the air and dust.

  14. Isocyanate and total inhalable particulate air measurements in the European wood panel industry.

    PubMed

    Vangronsveld, E; Berckmans, S; Verbinnen, K; Van Leeuw, C; Bormans, C

    2010-11-01

    It is well known that the use of MDI (methylene diphenyldiisocyanate) as an alternative for formaldehyde-based resins is seen as a responsible option to reduce formaldehyde emissions for CWP (Composite Wood Products) in buildings. However, there are concerns raised regarding the exposure risk of workers. The purpose of this article is to provide the reader with factual information to demonstrate that the use of MDI compared to other agents used in CWP production processes does not pose increased inhalation exposure risks for workers. Personal and area air measurements were carried out at nine Composite Wood Panel plants throughout Europe to assess potential inhalation exposures to MDI and wood dust as Total Inhalable Particulates (TIP). In total, 446 pairs of samples were collected for MDI and TIP of which 283 pairs were personal samples and the remaining 163 pairs were area samples collected at key locations along the production line. This data together with published formaldehyde exposure data has been used to evaluate the exposure safety margin opposite what are considered relevant occupational exposure limits. The methods used for sampling and analysing MDI and TIP are based on internationally accepted methods, i.e. MDHS 25/3 (or ISO 16702) for MDI, and MDHS 14/3 for TIP. The job functions with an increased exposure profile for TIP were the cleaners, drying operators and quality control staff, and for MDI, the cleaners and quality control staff. The areas with an increased exposure profile for TIP are the conveyor area from OSB blender to former area and the OSB press infeed, and for MDI the OSB weigh belt and OSB former bin area. The exposure safety margin opposite the selected exposure limits can be ranked as MDI>TIP>formaldehyde (high margin of safety to low margin of safety), indicating that the use of MDI also reduces the exposure risks to workers during production of CWP compared to formaldehyde. By reducing the airborne TIP concentrations, a respiratory sensitiser, MDI workplace concentrations in general can be reduced further. This can be achieved by improving design and/or maintenance and testing programmes of existing control measures, which should be in place already to effectively control exposure to TIP and formaldehyde. The airborne concentration of MDI at workstations situated after pressing (curing) is regarded as extremely low and likely mainly constituted by workplace emissions from elsewhere in the plant. Copyright © 2010 Elsevier GmbH. All rights reserved.

  15. Real time simulation application to monitor the stability limit of power system

    NASA Astrophysics Data System (ADS)

    Hartono, Kuo, Ming-Tse

    2017-06-01

    If the power system falls into an unsteady state, there will be voltage collapse in which the power system will be separated into small systems. Identifying the stability reserve in conformity with a certain practical operation condition is very important for the system management and operation. In fact, the global power system issue has caused serious outages due to voltage collapse such as in the United States-Canada in August 14, 2003; South London in August 28, 2003; southern Sweden and eastern Denmark in September 23, 2003; and Italy on September 28, 2003, and in Vietnam where power system problem led to power loss on 17 May 2005, 27 December 2006, 20 July 2007, and 10 September 2007. The analysis shows that the phenomenon is related to the loss of system stability. Thus, the operational system as well as the power system designs should be studied related to the issue of the system stability. To study the static stability of the power system, different approximate standards, called pragmatic criteria, were examined. Markovits has investigated the application of the standard of dP/dd to test the stability of the power button and dq/dU to check the voltage stability of the load button [1]. However, the storage stability when calculating standard dP/d d is usually much larger than the reserves when calculating standard dq/dU [1]. This paper presents a method to build a possible operation region in the power plane of load bus which works in comply with the stability limit to evaluate the stability reserve of the power system. This method is used to build a program to monitor the stability reserve of IEEE 39 Bus Power System in real time. To monitor the stability reserve of IEEE 39 nodes power system, articles based on the standard dq/dU was used to calculate the assessment. When using standard dq/dU to check for voltage stability load button, the amount of storage stability can be calculated by the following steps: first, transformed replacement scheme Masonry on the schematic rays of the source and node load stability was examined by using Gaussian elimination algorithm [1, 2, 3], then on the basis of ray diagrams the construction work, allowed domain of spare capacity load capacity in space and storage stability for the load button were determined. The GS-ODT program was built on the basis of Gaussian elimination algorithm and stable domain construction work algorithm for Masonic load button by dQ/dU pragmatic criteria. The GS-ODT program has a simple interface and easy to use with the main function is to identify the allowed domain for the load button and thus can assess visually stable reserve still according to the load capacity of the nodes of the IEEE 39 nodes power system in real-time.

  16. Assessing fullness of asthma patients' aerosol inhalers.

    PubMed

    Rickenbach, M A; Julious, S A

    1994-07-01

    The importance of regular medication in order to control asthma symptoms is recognized. However, there is no accurate mechanism for assessing the fullness of aerosol inhalers. The contribution to asthma morbidity of unexpectedly running out of inhaled medication is unknown. A study was undertaken to determine how patients assess inhaler fullness and the accuracy of their assessments, and to evaluate the floatation method of assessing inhaler fullness. An interview survey of 98 patients (51% of those invited to take part), using 289 inhalers, was completed at one general practice in Hampshire. One third of participants said they had difficulty assessing aerosol inhaler fullness and those aged 60 years and over were found to be more inaccurate in assessing fullness than younger participants. Shaking the inhaler to feel the contents move was the commonest method of assessment. When placed in water, an inhaler canister floating on its side with a corner of the canister valve exposed to air indicates that the canister is less than 15% full (sensitivity 90%, specificity 99%). Floating a canister in water provides an objective measurement of aerosol inhaler fullness. Providing the method is recommended by the aerosol inhaler manufacturer, general practitioners should demonstrate the floatation method to patients experiencing difficulty in assessing inhaler fullness.

  17. The chemo and the mona: inhalants, devotion and street youth in Mexico City.

    PubMed

    Gigengack, Roy

    2014-01-01

    This paper understands inhalant use--the deliberate inhalation of volatile solvents or glues with intentions of intoxication--as a socially and culturally constituted practice. It describes the inhalant use of young street people in Mexico City from their perspective ("the vicioso or inhalant fiend's point of view"). Even if inhalant use is globally associated with economic inequality and deprivation, there is a marked lack of ethnography. Incomprehension and indignation have blocked our understanding of inhalant use as a form of marginalised drug use. The current explanation models reduce inhalant consumption to universal factors and individual motives; separating the practice from its context, these models tend to overlook gustatory meanings and experiences. The paper is informed by long-term, on-going fieldwork with young street people in Mexico City. Fieldwork was done from 1990 through 2010, in regular periods of fieldwork and shorter visits, often with Mexican colleagues. We created extensive sets of fieldnotes, which were read and re-read. "Normalcy" is a striking feature of inhalant use in Mexico City. Street-wise inhabitants of popular neighbourhoods have knowledge about inhalants and inhalant users, and act accordingly. Subsequently, Mexico City's elaborate street culture of sniffing is discussed, that is, the range of inhalants used, how users classify the substances, and their techniques for sniffing. The paper also distinguishes three patterns of inhalant use, which more or less correlate with age. These patterns indicate embodiments of street culture: the formation within users of gusto, that is, an acquired appetite for inhalants, and of vicio, the inhalant fiends' devotion to inhalants. What emerges from the ethnographic findings is an elaborate street culture of sniffing, a complex configuration of shared perspectives and embodied practices, which are shaped by and shaping social exclusion. These findings are relevant to appreciate and address the inhalant fiends' acquired appetite and habit. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Salmeterol inhaler using a non-chlorinated propellant, HFA134a: systemic pharmacodynamic activity in healthy volunteers.

    PubMed Central

    Kirby, S. M.; Smith, J.; Ventresca, G. P.

    1995-01-01

    BACKGROUND--Metered dose inhalers for the treatment of asthma use chlorofluorocarbons as propellants. These face an international ban due to their effect on the ozone layer. Salmeterol has been reformulated using the non-chlorinated propellant Glaxo inhalation grade HFA134a. METHODS--The safety, tolerability and systemic pharmacodynamic activity of the salmeterol/HFA134a inhaler, the current salmeterol inhaler, and placebo (HFA134a) were compared in 12 healthy volunteers in a double blind, randomised crossover study using a cumulative dosing design. RESULTS--Safety and tolerability were similar and the response was related to the dose over the range used (50-400 micrograms) with both salmeterol inhalers. The salmeterol/HFA134a inhaler showed no differences from the current inhaler for pulse rate, blood pressure, tremor, QTc interval, and plasma glucose levels. The salmeterol/HFA134a inhaler had significantly less effect on plasma potassium levels. CONCLUSIONS--In healthy volunteers the salmeterol/HFA134a inhaler is at least as safe and well tolerated as the current salmeterol inhaler, and has similar systemic pharmacodynamic activity. PMID:7638815

  19. Inhalation Therapy in Horses.

    PubMed

    Cha, Mandy L; Costa, Lais R R

    2017-04-01

    This article discusses the benefits and limitations of inhalation therapy in horses. Inhalation drug therapy delivers the drug directly to the airways, thereby achieving maximal drug concentrations at the target site. Inhalation therapy has the additional advantage of decreasing systemic side effects. Inhalation therapy in horses is delivered by the use of nebulizers or pressured metered dose inhalers. It also requires the use of a muzzle or nasal mask in horses. Drugs most commonly delivered through inhalation drug therapy in horses include bronchodilators, antiinflammatories, and antimicrobials. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Inhalers and nebulizers: basic principles and preliminary measurements

    NASA Astrophysics Data System (ADS)

    Misik, Ondrej; Lizal, Frantisek; Asl, Vahid Farhikhteh; Belka, Miloslav; Jedelsky, Jan; Elcner, Jakub; Jicha, Miroslav

    2018-06-01

    Inhalers are hand-held devices which are used for administration of therapeutic aerosols via inhalation. Nebulizers are larger devices serving for home and hospital care using inhaled medication. This contribution describes the basic principles of dispersion of aerosol particles used in various types of inhalers and nebulizers, and lists the basic physical mechanisms contributing to the deposition of inhaled particles in the human airways. The second part of this article presents experimental setup, methodology and preliminary results of particle size distributions produced by several selected inhalers and nebulizers.

  1. Practice makes perfect: self-reported adherence a positive marker of inhaler technique maintenance.

    PubMed

    Azzi, Elizabeth; Srour, Pamela; Armour, Carol; Rand, Cynthia; Bosnic-Anticevich, Sinthia

    2017-04-24

    Poor inhaler technique and non-adherence to treatment are major problems in the management of asthma. Patients can be taught how to achieve good inhaler technique, however maintenance remains problematic, with 50% of patients unable to demonstrate correct technique. The aim of this study was to determine the clinical, patient-related and/or device-related factors that predict inhaler technique maintenance. Data from a quality-controlled longitudinal community care dataset was utilized. 238 patients using preventer medications where included. Data consisted of patient demographics, clinical data, medication-related factors and patient-reported outcomes. Mixed effects logistic regression was used to identify predictors of inhaler technique maintenance at 1 month. The variables found to be independently associated with inhaler technique maintenance using logistic regression (Χ 2 (3,n = 238) = 33.24, p < 0.000) were inhaler technique at Visit 1 (OR 7.1), device type (metered dose inhaler and dry powder inhalers) (OR 2.2) and self-reported adherent behavior in the prior 7 days (OR 1.3). This research is the first to unequivocally establish a predictive relationship between inhaler technique maintenance and actual patient adherence, reinforcing the notion that inhaler technique maintenance is more than just a physical skill. Inhaler technique maintenance has an underlying behavioral component, which future studies need to investigate. BEHAVIORAL ELEMENT TO CORRECT LONG-TERM INHALER TECHNIQUES: Patients who consciously make an effort to perfect asthma inhaler technique will maintain their skills long-term. Elizabeth Azzi at the University of Sydney, Australia, and co-workers further add evidence that there is a strong behavioral component to patients retaining correct inhaler technique over time. Poor inhaler technique can limit asthma control, affecting quality of life and increasing the chances of severe exacerbations. Azzi's team followed 238 patients to determine the key predictors of inhaler technique maintenance from factors including age, asthma knowledge and perceived future risks. Correct inhaler technique at initial assessment was the strongest predictor of long-term success, but this was strengthened further when patients reported good adherence to their own medication regimen. This suggests that maintaining correct inhaler technique is more than just a physical skill. Careful guidance towards this 'practice makes perfect' approach may improve patients' long-term technique maintenance.

  2. The optimization of iloprost inhalation under moderate flow of oxygen therapy in severe pulmonary arterial hypertension.

    PubMed

    Nakayama, Kazuhiko; Emoto, Noriaki; Tamada, Naoki; Okano, Mitsumasa; Shinkura, Yuto; Yanaka, Kenichi; Onishi, Hiroyuki; Hiraishi, Mana; Yamada, Shinichiro; Tanaka, Hidekazu; Shinke, Toshiro; Hirata, Ken-Ichi

    2018-01-01

    Inhaled iloprost efficiently improves pulmonary hemodynamics, exercise capacity, and quality of life in patients with pulmonary arterial hypertension (PAH). However, the process of inhalation is laborious for patients suffering from resting dyspnea. We describe a 75-year-old man with idiopathic PAH and a low gas transfer. Investigations excluded significant parenchymal lung disease and airflow obstruction (presuming FEV1/FVC ration > 70%). The patient struggled to complete iloprost inhalation due to severe dyspnea and hypoxemia. As such, we optimized the methods of oxygen supply from the nasal cannula to the trans-inhalator during the inhalation. We successfully shortened the inhalation duration that effectively reduced the laborious efforts required of patients. We also recorded pulmonary hemodynamics during inhalation of nebulized iloprost. This revealed significant hemodynamic improvement immediately following inhalation but hemodynamics returned to baseline within 2 hours. We hope that this optimization will enable patients with severe PAH to undergo iloprost inhalation.

  3. Relative source allocation of TDI to drinking water for derivation of a criterion for chloroform: a Monte-Carlo and multi-exposure assessment.

    PubMed

    Niizuma, Shun; Matsui, Yoshihiko; Ohno, Koichi; Itoh, Sadahiko; Matsushita, Taku; Shirasaki, Nobutaka

    2013-10-01

    Drinking water quality standard (DWQS) criteria for chemicals for which there is a threshold for toxicity are derived by allocating a fraction of tolerable daily intake (TDI) to exposure from drinking water. We conducted physiologically based pharmacokinetic model simulations for chloroform and have proposed an equation for total oral-equivalent potential intake via three routes (oral ingestion, inhalation, and dermal exposures), the biologically effective doses of which were converted to oral-equivalent potential intakes. The probability distributions of total oral-equivalent potential intake in Japanese people were estimated by Monte Carlo simulations. Even when the chloroform concentration in drinking water equaled the current DWQS criterion, there was sufficient margin between the intake and the TDI: the probability that the intake exceeded TDI was below 0.1%. If a criterion that the 95th percentile estimate equals the TDI is regarded as both providing protection to highly exposed persons and leaving a reasonable margin of exposure relative to the TDI, then the chloroform drinking water criterion could be a concentration of 0.11mg/L. This implies a daily intake equal to 34% of the TDI allocated to the oral intake (2L/d) of drinking water for typical adults. For the highly exposed persons, inhalation exposure via evaporation from water contributed 53% of the total intake, whereas dermal absorption contributed only 3%. Copyright © 2013 Elsevier Inc. All rights reserved.

  4. Formal recycling of e-waste leads to increased exposure to toxic metals: an occupational exposure study from Sweden.

    PubMed

    Julander, Anneli; Lundgren, Lennart; Skare, Lizbet; Grandér, Margaretha; Palm, Brita; Vahter, Marie; Lidén, Carola

    2014-12-01

    Electrical and electronic waste (e-waste) contains multiple toxic metals. However, there is currently a lack of exposure data for metals on workers in formal recycling plants. The objective of this study was to evaluate workers' exposure to metals, using biomarkers of exposure in combination with monitoring of personal air exposure. We assessed exposure to 20 potentially toxic metals among 55 recycling workers and 10 office workers at three formal e-waste recycling plants in Sweden. Workers at two of the plants were followed-up after 6 months. We collected the inhalable fraction and OFC (37-mm) fraction of particles, using personal samplers, as well as spot samples of blood and urine. We measured metal concentrations in whole blood, plasma, urine, and air filters using inductively coupled plasma-mass spectrometry following acid digestion. The air sampling indicated greater airborne exposure, 10 to 30 times higher, to most metals among the recycling workers handling e-waste than among the office workers. The exposure biomarkers showed significantly higher concentrations of chromium, cobalt, indium, lead, and mercury in blood, urine, and/or plasma of the recycling workers, compared with the office workers. Concentrations of antimony, indium, lead, mercury, and vanadium showed close to linear associations between the inhalable particle fraction and blood, plasma, or urine. In conclusion, our study of formal e-waste recycling shows that workers performing recycling tasks are exposed to multiple toxic metals. Copyright © 2014. Published by Elsevier Ltd.

  5. Assessing fullness of asthma patients' aerosol inhalers.

    PubMed Central

    Rickenbach, M A; Julious, S A

    1994-01-01

    BACKGROUND. The importance of regular medication in order to control asthma symptoms is recognized. However, there is no accurate mechanism for assessing the fullness of aerosol inhalers. The contribution to asthma morbidity of unexpectedly running out of inhaled medication is unknown. AIM. A study was undertaken to determine how patients assess inhaler fullness and the accuracy of their assessments, and to evaluate the floatation method of assessing inhaler fullness. METHOD. An interview survey of 98 patients (51% of those invited to take part), using 289 inhalers, was completed at one general practice in Hampshire. RESULTS. One third of participants said they had difficulty assessing aerosol inhaler fullness and those aged 60 years and over were found to be more inaccurate in assessing fullness than younger participants. Shaking the inhaler to feel the contents move was the commonest method of assessment. When placed in water, an inhaler canister floating on its side with a corner of the canister valve exposed to air indicates that the canister is less than 15% full (sensitivity 90%, specificity 99%). CONCLUSION. Floating a canister in water provides an objective measurement of aerosol inhaler fullness. Providing the method is recommended by the aerosol inhaler manufacturer, general practitioners should demonstrate the floatation method to patients experiencing difficulty in assessing inhaler fullness. PMID:7619099

  6. Household chemicals: management of intoxication and antidotes.

    PubMed

    Rauber-Lüthy, Christine; Kupferschmidt, Hugo

    2010-01-01

    Exposure to household products is very common, but in industrialized countries severe or fatal poisoning with household products is rare today, due to the legal restriction of sale of hazardous household products. The big challenge for physicians, pharmacologists and toxicologists is to identify the few exceptional life-threatening situations where immediate intervention is needed. Among thousands of innocuous products available for the household only very few are hazardous. Substances found in these products include detergents, corrosives, alcohols, hydrocarbons, and some of the essential oils. The ingestion of batteries and magnets and the exposure to cyanoacrylates (super glue) can cause complications in exceptional situations. Among the most dangerous substances still present in household products are ethylene glycol and methanol. These substances cause major toxicity only through their metabolites. Therefore, initial symptoms may be only mild or absent. Treatment even in asymptomatic patients has to be initiated as early as possible to inhibit production of toxic metabolites. For all substances not only the compound itself but also the route of exposure is relevant for toxicity. Oral ingestion and inhalation generally lead to most pronounced symptoms, while dermal exposure is often limited to mild irritation. However, certain circumstances need special attention. Exposure to hydrofluoric acid may lead to fatal hypocalcemia, depending on the concentration, duration of exposure, and area of the affected skin. Accidents with hydrocarbon pressure injectors and spray guns are very serious events, which may lead to amputation of affected limbs. Button batteries normally pass the gastrointestinal tract without problems even in toddlers; in rare cases, however, they get lodged in the esophagus with the risk of localized tissue damage and esophageal perforation.

  7. Problems of internalization: a button is a button is-not.

    PubMed

    Rockwell, Shelley

    2014-01-01

    Analysts hope to help the patient internalize a relationship with the analyst that contrasts with the original archaic object relation. In this paper, the author describes particular difficulties in working with a patient whose defenses and anxieties were bulimic, her movement toward internalization inevitably undone. Several issues are considered: how does the nonsymbolizing patient come to internalize the analyst's understanding, and when this does not hold, what is the nature of the patient's subsequent methods of dispersal? When the patient can maintain connection to the analyst as a good object, even fleetingly, in the depressive position, the possibility of internalization and symbolic communication is increased. © 2014 The Psychoanalytic Quarterly, Inc.

  8. Pectoralis Major Repair With Unicortical Button Fixation And Suture Tape.

    PubMed

    Sanchez, Anthony; Ferrari, Marcio B; Frangiamore, Salvatore J; Sanchez, George; Kruckeberg, Bradley M; Provencher, Matthew T

    2017-06-01

    Although injuries of the pectoralis major muscle are generally uncommon, ruptures of the pectoralis major are occasionally seen in younger, more active patients who participate in weightlifting activities. These injuries usually occur during maximal contraction of the muscle, while in extension and external rotation. In the case of a rupture, operative treatment is advocated especially in young, active patients regardless of the chronicity of the injury. Various surgical techniques for reattachment of the avulsed tendon have been described, but bone tunnel and suture anchor repair techniques are most widely used. In this Technical Note, we present our preferred technique for acute pectoralis major rupture repair involving use of cortical buttons for tendon stump-to-bone fixation.

  9. Free Bone Plug Quadriceps Tendon Harvest and Suspensory Button Attachment for Anterior Cruciate Ligament Reconstruction.

    PubMed

    Todor, Adrian; Caterev, Sergiu; Nistor, Dan Viorel; Khallouki, Youssef

    2016-06-01

    The most commonly used autografts for anterior cruciate ligament reconstruction are the bone-patellar tendon-bone and hamstring tendons. Each has its advantages and limitations. The bone-patellar tendon-bone autograft can lead to more donor-site morbidity, and the hamstring autograft can be unpredictable in size. The quadriceps tendon, with or without a bone block, has been described as an alternative graft source and has been used especially in revision cases, but in recent years, it has attracted attention even for primary cases. We report a technique for harvesting a free bone quadriceps tendon graft and attaching an extracortical button for femoral fixation for anterior cruciate ligament reconstruction.

  10. Optics survivability support, volume 2

    NASA Astrophysics Data System (ADS)

    Wild, N.; Simpson, T.; Busdeker, A.; Doft, F.

    1993-01-01

    This volume of the Optics Survivability Support Final Report contains plots of all the data contained in the computerized Optical Glasses Database. All of these plots are accessible through the Database, but are included here as a convenient reference. The first three pages summarize the types of glass included with a description of the radiation source, test date, and the original data reference. This information is included in the database as a macro button labeled 'LLNL DATABASE'. Following this summary is an Abbe chart showing which glasses are included and where they lie as a function of nu(sub d) and n(sub d). This chart is also callable through the database as a macro button labeled 'ABBEC'.

  11. Tactile Data Entry System

    NASA Technical Reports Server (NTRS)

    Adams, Richard J.

    2015-01-01

    The patent-pending Glove-Enabled Computer Operations (GECO) design leverages extravehicular activity (EVA) glove design features as platforms for instrumentation and tactile feedback, enabling the gloves to function as human-computer interface devices. Flexible sensors in each finger enable control inputs that can be mapped to any number of functions (e.g., a mouse click, a keyboard strike, or a button press). Tracking of hand motion is interpreted alternatively as movement of a mouse (change in cursor position on a graphical user interface) or a change in hand position on a virtual keyboard. Programmable vibro-tactile actuators aligned with each finger enrich the interface by creating the haptic sensations associated with control inputs, such as recoil of a button press.

  12. Manifold seal structure for fuel cell stack

    DOEpatents

    Collins, William P.

    1988-01-01

    The seal between the sides of a fuel cell stack and the gas manifolds is improved by adding a mechanical interlock between the adhesive sealing strip and the abutting surface of the manifolds. The adhesive is a material which can flow to some extent when under compression, and the mechanical interlock is formed providing small openings in the portion of the manifold which abuts the adhesive strip. When the manifolds are pressed against the adhesive strips, the latter will flow into and through the manifold openings to form buttons or ribs which mechanically interlock with the manifolds. These buttons or ribs increase the bond between the manifolds and adhesive, which previously relied solely on the adhesive nature of the adhesive.

  13. How to match the optimal currently available inhaler device to an individual child with asthma or recurrent wheeze.

    PubMed

    van Aalderen, Wim M; Garcia-Marcos, Luis; Gappa, Monika; Lenney, Warren; Pedersen, Søren; Dekhuijzen, Richard; Price, David

    2015-01-08

    Inhaled medications are the cornerstone of treatment in early childhood wheezing and paediatric asthma. A match between patient and device and a correct inhalation technique are crucial for good asthma control. The aim of this paper is to propose an inhaler strategy that will facilitate an inhaler choice most likely to benefit different groups of children. The main focus will be on pressurised metered dose inhalers and dry powder inhalers. In this paper we will discuss (1) practical difficulties with the devices and with inhaled therapy and (2) the optimal location for deposition of medicines in the lungs, and (3) we will propose a practical and easy way to make the best match between the inhaler device and the individual patient. We hope that this paper will contribute to an increased likelihood of treatment success and improved adherence to therapy.

  14. Dermal exposure assessment to benzene and toluene using charcoal cloth pads.

    PubMed

    van Wendel de Joode, Berna; Tielemans, Erik; Vermeulen, Roel; Wegh, Hillion; Kromhout, Hans

    2005-01-01

    Charcoal cloth pads have been used to assess volatile chemicals on the skin in a laboratory setting; however, they have not yet been applied to measure dermal exposure in occupational settings. This study aimed at evaluating whether charcoal pads can be used to assess dermal exposure to benzene and toluene in workers of a petrochemical plant. Inhalation and dermal exposure levels to benzene and toluene were assessed for workers of a petrochemical plant performing different jobs. Benzene uptake was assessed by determining S-phenylmercapturic acid in workers' urine samples. Dermal exposure levels on the charcoal pads were adjusted for ambient air levels of benzene and toluene by subtracting the amount of benzene or toluene measured in personal air from the amount of benzene or toluene measured on the charcoal pad. In general, measured external and internal exposure levels were low. The estimated contribution of the dermal route to internal benzene exposure levels was less than 0.06% for all jobs. Toluene personal air concentrations and benzene and toluene dermal exposure levels differed statistically significantly between job titles. For benzene, differences between jobs were larger for adjusted dermal exposures (maximum 17-fold, P = 0.02) than for inhalation exposures (maximum two-fold, P = 0.08). Also for toluene, although less clear, differences between jobs were larger for adjusted dermal exposures (maximum 23-fold, P = 0.01) as compared to inhalation exposures (maximum 10-fold, P = 0.01). Charcoal pads appeared to measure dermal exposures to benzene and toluene in addition to ambient air levels. Future studies applying charcoal cloth pads for the dermal exposure assessment at workplaces with higher dermal exposure to organic solvents may provide more insight into the biological relevance of dermal exposure levels measured by charcoal cloth pads. In addition, the design of the dermal sampler might be improved by configuring a dermal sampler, where part of the sampler is protected against direct contact and splashes, but still permeable for the gas phase. This design would most likely result in a better ability to correct for airborne concentrations at a given body location.

  15. Social rank and inhalant drug use: the case of lança perfume use in São Paulo, Brazil.

    PubMed

    Sanchez, Zila M; Noto, Ana R; Anthony, James C

    2013-07-01

    Lanca perfume (chloroform/ether) is an inhalant used mainly by higher social class students in Brazil. In light of the social and epidemiological features of lanca use, supply, and distribution, this investigation tests hypotheses about the degree to which use of inhalant lanca might be occurring in clusters, consistent with social sharing and diffusion, and might show a direct association with social rank even within the relatively privileged social context of private schools in a large mega-city of Latin America. Epidemiologic self-report survey data were from a large representative sample of urban post-primary private school students in São Paulo city, Brazil, in 2008. Newly incident lanca use was studied, first with estimates of clustering from the alternating logistic regressions (ALR) and then with conditional logistic regressions to probe into the hypothesized direct social rank association. ALR disclosed a clustering of newly incident lanca users within private school classrooms (pairwise odds ratio (PWOR)=2.1; 95% CI=1.3, 3.3; p=0.002) as well as clusters of recently active lanca use (PWOR=1.9; 95% CI=1.1, 3.3; p=0.02). Occurrence of lanca use within private school classrooms was directly associated with social rank (odds ratio (OR)=0.2; 95% CI=0.1, 0.8; p=0.03 in the contrast of lowest socio-economic status (SES) versus highest SES strata within classrooms). Thereafter, study of other drugs disclosed similar patterns. The clustering estimates are consistent with concepts of person-to-person sharing of lanca within private school classrooms as well as other dynamic processes that might promote lanca clusters in this context. An observed direct association with social rank is not specific to lanca use. Direct SES estimates across a broad profile of drug compounds suggests causal processes over and above the more specific initially hypothesized social rank gradients in the lanca diffusion process. A novel facet of the evidence is greater occurrence of drug use among the higher social rank private school students, which should be of interest in the social science community. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  16. Social Rank and Inhalant Drug Use: The Case of Lança Perfume Use in São Paulo, Brazil*

    PubMed Central

    Sanchez, Zila M.; Noto, Ana R.; Anthony, James C.

    2016-01-01

    Background Lanca perfume (chloroform/ether) is an inhalant used mainly by higher social class students in Brazil. In light of the social and epidemiological features of lanca use, supply, and distribution, this investigation tests hypotheses about the degree to which use of inhalant lanca might be occurring in clusters, consistent with social sharing and diffusion, and might show a direct association with social rank even within the relatively privileged social context of private schools in a large mega-city of Latin America. Methods Epidemiologic self-report survey data were from a large representative sample of urban post-primary private school students in São Paulo city, Brazil, in 2008. Newly incident lanca use was studied, first with estimates of clustering from the alternating logistic regressions (ALR) and then with conditional logistic regressions to probe into the hypothesized direct social rank association. Results ALR disclosed a clustering of newly incident lanca users within private school classrooms (pairwise odds ratio (PWOR) = 2.1; 95% CI = 1.3, 3.3; p = 0.002) as well as clusters of recently active lanca use (PWOR = 1.9; 95% CI = 1.1, 3.3; p = 0.02). Occurrence of lanca use within private school classrooms was directly associated with social rank (odds ratio (OR) = 0.2; 95% CI=0.1, 0.8; p=0.03 in the contrast of lowest socio-economic status (SES) versus highest SES strata within classrooms). Thereafter, study of other drugs disclosed similar patterns. Conclusions The clustering estimates are consistent with concepts of person-to-person sharing of lanca within private school classrooms as well as other dynamic processes that might promote lanca clusters in this context. An observed direct association with social rank is not specific to lanca use. Direct SES estimates across a broad profile of drug compounds suggests causal processes over and above the more specific initially hypothesized social rank gradients in the lanca diffusion process. A novel facet of the evidence is greater occurrence of drug use among the higher social rank private school students, which should be of interest in the social science community. PMID:23279923

  17. Comparison of particulate matter dose and acute heart rate variability response in cyclists, pedestrians, bus and train passengers.

    PubMed

    Nyhan, Marguerite; McNabola, Aonghus; Misstear, Bruce

    2014-01-15

    Exposure to airborne particulate matter (PM) has been linked to cardiovascular morbidity and mortality. Heart rate variability (HRV) is a measure of the change in cardiac autonomic function, and consistent links between PM exposure and decreased HRV have been documented in studies. This study quantitatively assesses the acute relative variation of HRV with predicted PM dose in the lungs of commuters. Personal PM exposure, HR and HRV were monitored in 32 young healthy cyclists, pedestrians, bus and train passengers. Inhaled and lung deposited PM doses were determined using a numerical model of the human respiratory tract which accounted for varying ventilation rates between subjects and during commutes. Linear mixed models were used to examine air pollution dose and HRV response relationships in 122 commutes sampled. Elevated PM2.5 and PM10 inhaled and lung deposited doses were significantly (p<0.05) associated with decreased HRV indices. Percent declines in SDNN (standard deviation of normal RR intervals) relative to resting, due to an inter-quartile range increase in PM10 lung deposited dose were stronger in cyclists (-6.4%, 95% CI: -11.7, -1.3) and pedestrians (-5.8%, 95% CI: -11.3, -0.5), in comparison to bus (-3.2%, 95% CI: -6.4, -0.1) and train (-1.8%, -7.5, 3.8) passengers. A similar trend was observed in the case of PM2.5 lung deposited dose and results for rMSSD (the square root of the squared differences of successive normal RR intervals) followed similar trends to SDNN. Inhaled and lung deposited doses accounting for varying ventilation rates between modes, individuals and during commutes have been neglected in other studies relating PM to HRV. The findings here indicate that exercise whilst commuting has an influence on inhaled PM and PM lung deposited dose, and these were significantly associated with acute declines in HRV, especially in pedestrians and cyclists. © 2013.

  18. New evaluation index for the retainability of a swimmer’s horizontal posture

    PubMed Central

    2017-01-01

    This study aims to investigate the effect of changes in buoyancy when a swimmer respires in a horizontal posture. We attempted to evaluate the levelness of swimmers’ streamline posture by simultaneously measuring the lung capacity and buoyancy under water. The buoyancy was measured based on the changes in the vertical loads of the upper and lower limbs on the subjects’ streamline posture under water. The horizontal x-axis as lung ventilation and the vertical y-axis as buoyancy forms a linear equation y = ax + b. The relation between hand (upper-limb) buoyancy and lung ventilation is defined as y = a1x + b1 and that between foot (lower-limb) buoyancy and lung ventilation as y = a2x + b2. Horizontal levelness was calculated as a ratio by dividing a2 by a1 using the inclination (a) values from these formulas for an underwater streamline posture. We defined this ratio as the breathing–balance (BB) ratio. Although the performance levels in the present study did not show any difference in the absolute quantity of air that humans can inhale in a streamline posture, the BB ratio was higher in a statistically significant manner in junior swimmers competing at international levels compared with the other groups of subjects (P < 0.001). This statistical difference in horizontal levelness, despite the absence of a noticeable difference in the absolute quantity of inhaled air, may be attributable to the way in which each person inhales and exhales air. Top-level junior swimmers that exhibited a high BB ratio might have inhaled in a way that would counteract the sinking of the lower limbs, for example, through abdominal respiration. When exhaling, on the other hand, they might have let out air gradually to mitigate the acceleration force involved in submerging the lower limbs. PMID:28486565

  19. Endotoxin exposure and changes in short-term pulmonary function among sewage workers.

    PubMed

    Cyprowski, Marcin; Sobala, Wojciech; Buczyńska, Alina; Szadkowska-Stańczyk, Irena

    2015-01-01

    The inhaled endotoxin is considered as a causative factor in the process of acute bronchial obstruction, which can be measured by a decrease in forced expiratory volume in 1 s (FEV1). The aim of this study was to assess endotoxin exposure among sewage treatment plant workers (STPW) and its effect on across-shift changes in respiratory airflow. A group of 78 STPW from a large sewage treatment plant was studied. Inhalable dust for endotoxin assessment was collected using personal aerosol samplers. Endotoxin was assayed with the kinetic, chromogenic Limulus amebocyte lysate test. Across-shift spirometric measurements were performed on Mondays, after 2-days absence from work, with the use of portable spirometer. The forced vital capacity (FVC), and FEV1 parameters were analyzed. Multifactor regression modeling was performed to determine parameters significantly associated with endotoxin exposure. The concentration of inhalable dust and endotoxin ranged from 0.01-1.38 mg/m3 and 0.68-214 endotoxin units per cubic meter of air (EU/m3), respectively. Endotoxins were characterized with the skewed distribution (arithmetic mean (AM) = 38.8 EU/m3, geometric mean (GM) = 15.4 EU/m3, geometric standard deviation (GSD) = 4.21). Through the use of multifactor analysis, which excluded the main confounders (inhalable dust and smoking habit) it was found that, despite low levels of endotoxin, it had significant impact on the observed across-shift decline in FEV1 (p = 0.044). For this parameter, the regression slope was additionally calculated (r = -0.017, p = 0.071). Relatively low levels of endotoxin among sewage treatment plant workers may cause small, but significant across-shift declines in FEV1. The observed relationship was independent of organic dust concentrations and smoking habit. The respiratory protection should be provided for STPW. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  20. Is the 'blue' colour convention for inhaled reliever medications important? A UK-based survey of healthcare professionals and patients with airways disease.

    PubMed

    Fletcher, Monica; Scullion, Jane; White, John; Thompson, Bronwen; Capstick, Toby

    2016-11-03

    In many countries, short-acting β 2 -agonist inhalers have traditionally been coloured blue. This inhaled therapy has also conventionally been known as a 'reliever' by patients and healthcare professionals (HCPs), in comparison with 'preventer' medications (inhaled steroids). With the rapidly changing market in inhaled therapy for COPD and asthma and growing numbers of devices, there has been some concern that the erosion of traditional colour conventions is leading to patients (and HCPs) becoming confused about the role of different therapies. In order to assess whether there was concern over the perceived changing colour conventions, the UK Inhaler Group carried out a large online survey of patients and HCPs. The aim was to determine how patients and HCPS identify and describe inhaled drugs, and how this might impact on use of medicines and safety. The results of the survey highlighted the importance of the term 'blue inhaler' for patients with only 11.3% never referring to the colour when referring to their inhaler. For HCPs, 95% felt colour conventions were important when referring to reliever medication. In addition, HCPs appear to refer to inhalers mainly by colour when talking to patients. Our conclusions were that the concept of a 'blue inhaler' remains important to patients and healthcare professionals. These results add to the debate about the need to formalise the colour coding of inhaled therapies, in particular using the colour blue for inhalers for rapid relief of symptoms, as this convention may be an important measure and contributor to patient safety. Our survey should provide impetus for all interested parties to discuss and agree a formal industry-wide approach to colour coding of inhaled therapies for the benefit of patients and carers and HCPs.

  1. Ventilation requirements in buildings—I. Control of occupancy odor and tobacco smoke odor

    NASA Astrophysics Data System (ADS)

    Cain, William S.; Leaderer, Brian P.; Isseroff, Ruth; Berglund, Larry G.; Huey, Raymond J.; Lipsitt, Eric D.; Perlman, Dan

    Psychophysical measurements of odor, supplemented with certain physical measurements, were taken to examine ventilation requirements during smoking and nonsmoking occupancy in an environmental chamber. The facility provided the means to compare impressions of visitors (persons who inhaled air from the chamber only briefly) with impressions of occupants. For nonsmoking occupancy, 47 combinations of temperature, humidity, ventilation rate and occupancy density were examined. Odor level depended entirely on ventilation rate per person irrespective of the number of persons in the chamber. The ventilation necessary to satisfy 75 % of visitors equalled only about 4 ℓ s -1 per person. Occupants, however, were satisfied with far less. In an array of 38 conditions of smoking occupancy, the ventilation deemed necessary to satisfy 75 % of visitors under customary conditions of occupancy equalled 17.5 ℓ s -1 per person. For both smoking and nonsmoking conditions, a combination of high temperature (25.5°C) and humidity (r.h. > 70 %) exacerbated the odor problem. During smoking, carbon monoxide rarely reached dangerous levels, but suspended particulate matter often reached levels considered unacceptable outdoors. The results highlight the energy penalty incurred in ventilation for smoking occupancy.

  2. Customizing inhaled therapy to meet the needs of COPD patients.

    PubMed

    Fromer, Leonard; Goodwin, Elizabeth; Walsh, John

    2010-03-01

    Chronic obstructive pulmonary disease (COPD) is a progressive disease characterized by airflow limitation resulting from emphysema and chronic bronchitis. Inhaled therapy is the major therapeutic approach for treating COPD. Multiple inhaler medications are available in the United States and are delivered by a variety of different devices: metered-dose inhalers, dry powdered inhalers, and nebulizers. Each inhaler device has unique requirements for use that must be correctly performed by the patient for successful drug delivery. Patients with COPD represent a medically diverse population, with each patient having distinct characteristics, such as lung function, comorbidities, cognitive functions, hand strength, and lifestyle. These characteristics impact the patient's ability to properly use specific inhaler devices and therefore affect adherence to therapy, therapeutic outcomes, and quality of life. It is estimated that between 28% to 68% of patients do not use metered-dose inhalers or dry powder inhalers correctly. Worsening symptoms or increased frequency of exacerbations may not always indicate disease progression but may indicate a patient's inability to use their inhaler device properly. This review discusses the patient- and device-specific factors to be considered when choosing an inhaled therapy, which will be concordant with the patient's medical needs, preferences, and lifestyle. The review also considers how the ideas underlying the patient-centered medical home model can be incorporated into the choice and use of inhaler device for a given patient with COPD to improve treatment outcomes.

  3. Mechanism of failure of the Cabrol procedure: A computational fluid dynamic analysis.

    PubMed

    Poullis, M; Pullan, M

    2015-12-01

    Sudden failure of the Cabrol graft is common and frequently fatal. We utilised the technique of computational fluid dynamic (CFD) analysis to evaluate the mechanism of failure and potentially improve on the design of the Cabrol procedure. CFD analysis of the classic Cabrol procedure and a number of its variants was performed. Results from this analysis was utilised to generate further improved geometric options for the Cabrol procedure. These were also subjected to CFD analysis. All current Cabrol and variations of the Cabrol procedure are predicated by CFD analysis to be prone to graft thrombosis, secondary to stasis around the right coronary artery button. The right coronary artery flow characteristics were found to be the dominant reason for Cabrol graft failure. A simple modification of the Cabrol geometry is predicated to virtually eliminate any areas of blood stasis, and graft failure. Modification of the Cabrol graft geometry, due to CFD analysis may help reduce the incidence of graft thrombosis. A C shaped Cabrol graft with the right coronary button anastomosed to its side along its course from the aorta to the left coronary button is predicted to have the least thrombotic tendency. Clinical correlation is needed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Grasp specific and user friendly interface design for myoelectric hand prostheses.

    PubMed

    Mohammadi, Alireza; Lavranos, Jim; Howe, Rob; Choong, Peter; Oetomo, Denny

    2017-07-01

    This paper presents the design and characterisation of a hand prosthesis and its user interface, focusing on performing the most commonly used grasps in activities of daily living (ADLs). Since the operation of a multi-articulated powered hand prosthesis is difficult to learn and master, there is a significant rate of abandonment by amputees in preference for simpler devices. In choosing so, amputees chose to live with fewer features in their prosthesis that would more reliably perform the basic operations. In this paper, we look simultaneously at a hand prosthesis design method that aims for a small number of grasps, a low complexity user interface and an alternative method to the current use of EMG as a preshape selection method through the use of a simple button; to enable amputees to get to and execute the intended hand movements intuitively, quickly and reliably. An experiment is reported at the end of the paper comparing the speed and accuracy with which able-bodied naive subjects are able to select the intended preshapes through the use of a simplified EMG method and a simple button. It is shown that the button was significantly superior in the speed of successful task completion and marginally superior in accuracy (success of first attempt).

  5. Inhalant Use, Abuse, and Dependence among Adolescent Patients: Commonly Comorbid Problems.

    ERIC Educational Resources Information Center

    Sakai, Joseph T.; Hall, Shannon K.; Mikulich-Gilbertson, Susan K.; Crowley, Thomas J.

    2004-01-01

    Objective: Little is known about adolescents with DSM-IV-defined inhalant abuse and dependence. The aim of this study was to compare comorbidity among (1) adolescents with inhalant use disorders, (2) adolescents who reported using inhalants without inhalant use disorder, and (3) other adolescent patients drawn from an adolescent drug and alcohol…

  6. Effectiveness of Various Methods of Teaching Proper Inhaler Technique.

    PubMed

    Axtell, Samantha; Haines, Seena; Fairclough, Jamie

    2017-04-01

    To compare the effectiveness of 4 different instructional interventions in training proper inhaler technique. Randomized, noncrossover trial. Health fair and indigent clinic. Inhaler-naive adult volunteers who spoke and read English. Subjects were assigned to complete the following: (1) read a metered dose inhaler (MDI) package insert pamphlet, (2) watch a Centers for Disease Control and Prevention (CDC) video demonstrating MDI technique, (3) watch a YouTube video demonstrating MDI technique, or (4) receive direct instruction of MDI technique from a pharmacist. Inhaler use competency (completion of all 7 prespecified critical steps). Of the 72 subjects, 21 (29.2%) demonstrated competent inhaler technique. A statistically significant difference between pharmacist direct instruction and the remaining interventions, both combined ( P < .0001) and individually ( P ≤ .03), was evident. No statistically significant difference was detected among the remaining 3 intervention groups. Critical steps most frequently omitted or improperly performed were exhaling before inhalation and holding of breath after inhalation. A 2-minute pharmacist counseling session is more effective than other interventions in successfully educating patients on proper inhaler technique. Pharmacists can play a pivotal role in reducing the implications of improper inhaler use.

  7. A cross-sectional observational study to assess inhaler technique in Saudi hospitalized patients with asthma and chronic obstructive pulmonary disease

    PubMed Central

    Ammari, Maha Al; Sultana, Khizra; Yunus, Faisal; Ghobain, Mohammed Al; Halwan, Shatha M. Al

    2016-01-01

    Objectives: To assess the proportion of critical errors committed while demonstrating the inhaler technique in hospitalized patients diagnosed with asthma and chronic obstructive pulmonary disease (COPD). Methods: This cross-sectional observational study was conducted in 47 asthmatic and COPD patients using inhaler devices. The study took place at King Abdulaziz Medical City, Riyadh, Saudi Arabia between September and December 2013. Two pharmacists independently assessed inhaler technique with a validated checklist. Results: Seventy percent of patients made at least one critical error while demonstrating their inhaler technique, and the mean number of critical errors per patient was 1.6. Most patients used metered dose inhaler (MDI), and 73% of MDI users and 92% of dry powder inhaler users committed at least one critical error. Conclusion: Inhaler technique in hospitalized Saudi patients was inadequate. Health care professionals should understand the importance of reassessing and educating patients on a regular basis for inhaler technique, recommend the use of a spacer when needed, and regularly assess and update their own inhaler technique skills. PMID:27146622

  8. Use of Respimat® Soft Mist™ Inhaler in COPD patients

    PubMed Central

    Anderson, Paula

    2006-01-01

    Events of the past decade have stimulated development of new drug formulations and delivery devices that have improved the efficiency, ease of use, and environmental impact of inhaled drug therapy. Respimat® Soft Mist™ Inhaler is a novel, multidose, propellant-free, hand-held, liquid inhaler that represents a new category of inhaler devices. The aerosol cloud generated by Respimat contains a higher fraction of fine particles than most pressurized metered dose inhalers (pMDIs) and dry powder inhalers (DPIs), and the aerosol spray exits the inhaler more slowly and for a longer duration than with pMDIs. This translates into higher lung drug deposition and lower oropharyngeal deposition, making it possible to give lower nominal doses of delivered drugs without lowering efficacy. In clinical trials in patients with COPD, bronchodilator drugs delivered from Respimat were equally effective at half of the dose delivered from a pMDI. In one study of inhaler preference, Respimat was preferred over the pMDI by patients with COPD and other obstructive lung diseases. Respimat is a valuable addition to the range of inhaler devices available to the patient with COPD. PMID:18046862

  9. Semantic processing in subliminal face stimuli: an EEG and tDCS study.

    PubMed

    Kongthong, Nutchakan; Minami, Tetsuto; Nakauchi, Shigeki

    2013-06-07

    Whether visual subliminal processing involves semantic processing is still being debated. To examine this, we combined a passive electroencephalogram (EEG) study with an application of transcranial direct current stimulation (tDCS). In the masked-face priming paradigm, we presented a subliminal prime preceding the target stimulus. Participants were asked to determine whether the target face was a famous face, indicated by a button press. The prime and target pair were either the same person's face (congruent) or different person's faces (incongruent), and were always both famous or both non-famous faces. Experiments were performed over 2 days: 1 day for a real tDCS session and another for a sham session as a control condition. In the sham session, a priming effect, reflected in the difference in amplitude of the late positive component (250-500 ms to target onset), was observed only in the famous prime condition. According to a previous study, this effect might indicate a subliminal semantic process [10]. Alternatively, a priming effect toward famous primes disappeared after tDCS stimulation. Our results suggested that a subliminal process might not be limited to processes in the occipital and temporal areas, but may proceed to the semantic level processed in prefrontal cortex. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  10. Electronic collection system for spacelab mission timeline requirements

    NASA Technical Reports Server (NTRS)

    Lindberg, James P.; Piner, John R.; Huang, Allen K. H.

    1995-01-01

    This paper describes the Functional Objective Requirements Collection System (FORCS) software tool that has been developed for use by Principal Investigators (PI's) and Payload Element Developers (PED's) on their own personal computers to develop on-orbit timelining requirements for their payloads. The FORCS tool can be used either in a totally stand-alone mode, storing the information in a local file on the user's personal computer hard disk or in a remote mode where the user's computer is linked to a host computer containing the integrated database of the timeline requirements for all of the payloads on a mission. There are a number of features incorporated in the FORCS software to assist the user. The user may move freely back and forth between the various forms for inputting the data. Several methods are used to input the information, depending on the type of the information. These methods range from filling in text boxes, using check boxes and radio buttons, to inputting information into a spreadsheet format. There are automated features provided to assist in developing the proper format for the data, ranging from limit checking on some of the parameters to automatic conversion of different formats of time data inputs to the one standard format used for the timeline scheduling software.

  11. Inhalation Injuries

    MedlinePlus

    ... breathe in toxic substances, such as smoke (from fires), chemicals, particle pollution, and gases. Inhalation injuries can ... of thermal injuries. Over half of deaths from fires are due to inhalation injuries. Symptoms of inhalation ...

  12. Pandemic Flu

    MedlinePlus

    ... Address What's this? Submit What's this? Submit Button Influenza Types Seasonal Avian Swine Variant Pandemic Other Pandemic Influenza Language: English (US) Español Recommend on Facebook Tweet ...

  13. Diarrhea and Swimming

    MedlinePlus

    ... Health International Recreational Water RWIs, Swimmer Hygiene, & Behavioral Science Historical CDC Manuals Health Promotion Materials Brochures Buttons & Banners Fact Sheets Infographics Clean It Up, Swimmers Make a ...

  14. A Survey of Inhalant Use Disorders among Delinquent Youth: Prevalence, Clinical Features, and Latent Structure of DSM-IV Diagnostic Criteria

    PubMed Central

    Howard, Matthew O; Perron, Brian E

    2009-01-01

    Background Inhalant use is among the most pernicious and poorly understood forms of adolescent substance use. Many youth in the juvenile justice system have used inhalants, but little is known about inhalant use disorders (IUDs) in antisocial youth populations. The purpose of this study was to examine the prevalence, clinical features, and latent structure of DSM-IV IUDs in a state population of antisocial youth. Methods Cross-sectional survey conducted in 2003. Of 740 youth residing in Missouri State Division of Youth Services' (MDYS) residential treatment facilities at the time the study was conducted, 723 (97.7%) completed interviews. Eighty-seven percent were male, with a mean age of 15.5 (SD = 1.2). Nearly 4 in 10 youth (38.5%; n = 279) reported lifetime inhalant use. Youth ranged from very mildly to severely antisocial. Results Of 279 inhalant users, 52 (18.6%) met DSM-IV inhalant abuse criteria and 79 (28.3%) met inhalant dependence criteria. Five of 10 IUD criteria were met by > 10% of the total sample. Latent class analyses demonstrated a substantial concordance between DSM-IV-defined IUDs and an empirically-derived classification based on responses to DSM-IV IUD diagnostic criteria. Conclusion IUDs and constituent criteria were prevalent among youth in the juvenile justice system. Two groups of problem inhalant users were identified, symptomatic users-DSM-IV inhalant abuse and highly symptomatic users-DSM-IV inhalant dependence, which differed primarily in severity of inhalant-related problems. Inhalant screening, prevention and treatment efforts in juvenile justice settings are rarely delivered, but critically needed. PMID:19267939

  15. Evaluation of the potential use of probiotic strain Lactobacillus plantarum 299v in lactic fermentation of button mushroom fruiting bodies.

    PubMed

    Jabłońska-Ryś, Ewa; Sławińska, Aneta; Radzki, Wojciech; Gustaw, Waldemar

    2016-01-01

    The available literature does not provide data on the application of probiotic strains in mushroom processing. The aim of the study was to evaluate the potential to use the L. plantarum 299v strain with documented probiotic properties in the process of lactic fermentation of button mushroom fruiting bodies (Agaricus bisporus). Fresh button mushroom fruiting bodies and cultures of lactic acid bacteria L. plantarum Ib and a probiotic strain L. plantarum 299v were the material analysed. Sensory evaluation was performed with a 5-point scale, an instrumental method of colour measurement based on the CIA L*a*b* scale, total phenolic compounds were determined with the Folin method, antioxidant properties were assayed with the DPPH radical test, and reducing power was determined using the FRAP method. After a week-long lactic fermentation, the pH value in the samples declined to a level of 3.6 (L. plantarum Ib) and 3.75 (L. plantarum 299v); these values persisted or decreased slightly during the period of maturation of the fermented samples under refrigeration. Fermented mushrooms were assigned high grades in the organoleptic evaluation. The colour analysis revealed significant changes in the values of the L*a*b* parameters in the fermented product, in comparison with fresh mushrooms. Blanching contributed to a significant decrease in the content of total phenolic compounds in the mushroom fruiting bodies and to a decline in antioxidant activity. Mushrooms fermented with the probiotic strain were characterised by higher phenolic compound content and higher antioxidant activity. L. plantarum 299v strain with documented probiotic properties can be applied in fermentation of button mushroom fruiting bodies. Products obtained with the use of both strains were characterised by good sensory properties. The type of strain used in the lactic fermentation of mushroom fruiting bodies had an effect on the phenolic compound content and antioxidant properties of the final product.

  16. Modeling and test of a kinaesthetic actuator based on MR fluid for haptic applications.

    PubMed

    Yang, Tae-Heon; Koo, Jeong-Hoi; Kim, Sang-Youn; Kwon, Dong-Soo

    2017-03-01

    Haptic display units have been widely used for conveying button sensations to users, primarily employing vibrotactile actuators. However, the human feeling for pressing buttons mainly relies on kinaesthetic sensations (rather than vibrotactile sensations), and little studies exist on small-scale kinaesthetic haptic units. Thus, the primary goals of this paper are to design a miniature kinaesthetic actuator based on Magneto-Rheological (MR) fluid that can convey various button-clicking sensations and to experimentally evaluate its haptic performance. The design focuses of the proposed actuator were to produce sufficiently large actuation forces (resistive forces) for human users in a given size constraint and to offer a wide range of actuation forces for conveying vivid haptic sensations to users. To this end, this study first performed a series of parametric studies using mathematical force models for multiple operating modes of MR fluid in conjunction with finite element electromagnetism analysis. After selecting design parameters based on parametric studies, a prototype actuator was constructed, and its performance was evaluated using a dynamic mechanical analyzer. It measured the actuator's resistive force with a varying stroke (pressed depth) up to 1 mm and a varying input current from 0 A to 200 mA. The results show that the proposed actuator creates a wide range of resistive forces from around 2 N (off-state) to over 9.5 N at 200 mA. In order to assess the prototype's performance in the terms of the haptic application prospective, a maximum force rate was calculated to determine just noticeable difference in force changes for the 1 mm stoke of the actuator. The results show that the force rate is sufficient to mimic various levels of button sensations, indicating that the proposed kinaesthetic actuator can offer a wide range of resistive force changes that can be conveyed to human operators.

  17. Identification and topographic localization of metallic foreign bodies by metal detector.

    PubMed

    Muensterer, Oliver J; Joppich, Ingolf

    2004-08-01

    Exact localization of ingested metal objects is necessary to guide therapy. This study prospectively evaluates the accuracy of foreign body (FB) identification and localization by metal detector (MTD) in a systematic topographic fashion. Patients who presented after an alleged or witnessed metal FB ingestion were scanned with an MTD. In case of a positive signal, the location was recorded in a topographic diagram, and radiographs were obtained. The diagnostic accuracy of the MTD scan for FB identification and topographic localization was determined by chi(2) analysis, and concordance was calculated by the McNemar test and expressed as kappa. A total of 70 MTD examinations were performed on 65 patients (age 6 months to 16 years); 5 patients were scanned twice on different days. The majority had swallowed coins and button batteries (n = 41). Of these, 29 items were correctly identified, and 11 of 12 were correctly ruled out (coins and button batteries: sensitivity, 100% [95% Confidence Interval 95% to 100%]; specificity, 91.7% [95% CI 76% to 100%], kappa = 0.94). When all metallic objects were included, 41 of 46 were correctly identified, and 22 of 24 were correctly ruled out (sensitivity, 89.1% [95% CI 80% to 98%]; specificity, 91.7% [95% CI 81% to 100%], kappa = 0.78). Five miscellaneous objects were not identified (sensitivity for items other than coins and button batteries 71% [95% CI 49% to 92%], kappa = 0.56). Localization by MTD was correct in 30 of 41 identified objects (73%). The error rates of junior and senior pediatric surgery residents did not differ significantly (P =.82). Ingested coins and button batteries can be safely and accurately found by metal detector. For these indications, the MTD is a radiation-free diagnostic alternative to conventional radiographs. Other items, however, cannot be ruled out reliably by MTD. In these cases, radiographic imaging is still indicated.

  18. [Outcomes and complications of Tightrope button plate for repairing acromioclavicular dislocation].

    PubMed

    Zuo, Yong-Xiang; Ma, Zi-Ping

    2017-10-25

    To study the clinical outcome and complications of Tightrope button plate for repairing acromioclavicular dislocation of Rockwood type III to V. From May 2014 to December 2016, 17 patients with acromioclavicular dislocation of type III-V were treated with Tightrope button plate including 10 males and 7 females with an average age 39.8 years old ranging from 20 to 68 years old. Four patients were treated with arthroscopy and 17 patients were treated with mini-invasive by X-ray assisted. Shoulder function, X-ray and complications after operation were assessed. All patients were followed up for 5 to 23 months with a mean of 10.8 months. All patients got satisfying reduction immediately postoperatively. Among them, 1 case of clavicle end wound foreign body reaction, rupture, effusion, healing after the second suture; 1 case of foreign body granuloma formation at the end of clavicle were resected and removed at 4 months after operation; 3 cases loss reduction(less than 50% of acromioclavicular joint). No coracoid fracture and suture breakage observed. The shoulder mobility was restored in 15 cases at 4 to 6 weeks postoperatively, and the shoulder adhesion in 2 cases was delayed to 5 to 7 months after operation. The Constant scores were improved from 46.9±6.0 preoperatively to 92.7±4.0 at the final follow-up. X-ray evaluation of postoperative coracoclavicular tunnel location, patients' coracoclavicular tunnel with mini-invasive fluoroscopy all closed to the ideal position (across the clavicle vertically through the coracoid base center), while different degree of tunnel position deviation were observed in arthroscopic patients. Tightrope button plate for the treatment of acromioclavicular joint dislocation had advantages of minimally invasive, effective, good clinical results, the majority of common complications does not affect efficacy. Small incision X-ray method can provide more satisfactory and reliable tunnel location.

  19. Imaging button battery ingestions and insertions in children: a 15-year single-center review.

    PubMed

    Pugmire, Brian S; Lin, Tom K; Pentiuk, Scott; de Alarcon, Alessandro; Hart, Catherine K; Trout, Andrew T

    2017-02-01

    Recent studies have shown an increase in morbidity associated with button battery ingestions in children. To perform a comprehensive, imaging-focused review of all patients with confirmed button battery ingestions/insertions imaged at our institution in the last 15 years. Radiology reports from Jan. 1, 2000, to July 12, 2015, were searched for the terms "battery" and "batteries." Confirmed cases of battery ingestion/insertion for which images were available were reviewed. Cases were reviewed for imaging studies performed, imaging findings, patient demographics, clinical history and management. Two pediatric gastroenterologists reviewed endoscopic images and graded mucosal injuries in selected cases. Two hundred seventy-six cases were reviewed. All patients were imaged with radiography, 19 with fluoroscopy (6.8%), and 4 with CT (1.4%). Batteries retained in the esophagus (n = 27, 9.8%) were larger in diameter on average than those that had passed distally (22.1 ± 3.3 mm vs. 13.7 ± 1.6 mm, P<0.0001). Battery diameter ≥20 mm was associated with esophageal impaction (P<0.0001) and higher grade esophageal injury (P<0.0001). Mean battery diameter was greater for patients with grade 1 or higher mucosal injury than for patients with no mucosal injury (22.1 ± 2.1 mm vs. 14.7 ± 4.5 mm, P<0.0001). Sixteen percent (4/25) of patients with grade ≥1 esophageal injury had batteries in the stomach on initial imaging. Five patients (1.8%) had serious clinical complications (e.g., esophageal perforation, tracheoesophageal fistula). Button batteries >20mm in diameter warrant increased clinical scrutiny due to higher likelihood and severity of injury. Implementation of recent pediatric gastroenterology societal guidelines will likely lead to a substantial increase in the number of CT and MRI examinations.

  20. Fiber inhalability and head deposition in rats and humans. ...

    EPA Pesticide Factsheets

    Due to their dimensions and long durability, inhaled asbestos fibers clear slowly from lung airways. Retained fibers may injure the epithelium, interact with macrophages, or translocate to the interstitium to result in various respiratory diseases. Therefore, calculations of fiber inhalability, deposition, and retention in respiratory tract regions of both rats and humans are crucial, both to assess the health risk of fiber exposures and to facilitate inferences from rat inhalation studies. Rat inhalation experiments are underway at the EPA and NIEHS. A model of fiber inhalability and initial deposition in the human and rat nasal cavity was developed. Existing models for particles were extended to fibers by replacing particle diameter with an equivalent fiber diameter. Since fiber inhalability into the respiratory tract and deposition in the extra thoracic airways depended mainly on its inertia, equivalent impaction diameters were derived and substituted in expressions for spherical particle diameter to determine fiber inhalability and nasal losses. Fiber impaction diameter depended strongly on its orientation in the air. Highest inhalability was obtained when fibers were aligned perpendicular to the flow streamlines in the inhaled air. However, detailed calculations of fiber transport in slow moving air such as that in the atmosphere and in lung airways showed that fibers stayed primarily aligned (parallel) to the flow. Therefore, for inhalability calculations,

  1. Evaluation of a novel educational strategy, including inhaler-based reminder labels, to improve asthma inhaler technique.

    PubMed

    Basheti, Iman A; Armour, Carol L; Bosnic-Anticevich, Sinthia Z; Reddel, Helen K

    2008-07-01

    To evaluate the feasibility, acceptability and effectiveness of a brief intervention about inhaler technique, delivered by community pharmacists to asthma patients. Thirty-one pharmacists received brief workshop education (Active: n=16, CONTROL: n=15). Active Group pharmacists were trained to assess and teach dry powder inhaler technique, using patient-centered educational tools including novel Inhaler Technique Labels. Interventions were delivered to patients at four visits over 6 months. At baseline, patients (Active: 53, CONTROL: 44) demonstrated poor inhaler technique (mean+/-S.D. score out of 9, 5.7+/-1.6). At 6 months, improvement in inhaler technique score was significantly greater in Active cf. CONTROL patients (2.8+/-1.6 cf. 0.9+/-1.4, p<0.001), and asthma severity was significantly improved (p=0.015). Qualitative responses from patients and pharmacists indicated a high level of satisfaction with the intervention and educational tools, both for their effectiveness and for their impact on the patient-pharmacist relationship. A simple feasible intervention in community pharmacies, incorporating daily reminders via Inhaler Technique Labels on inhalers, can lead to improvement in inhaler technique and asthma outcomes. Brief training modules and simple educational tools, such as Inhaler Technique Labels, can provide a low-cost and sustainable way of changing patient behavior in asthma, using community pharmacists as educators.

  2. Ease-of-use preference for the ELLIPTA® dry powder inhaler over a commonly used single-dose capsule dry powder inhaler by inhalation device-naïve Japanese volunteers aged 40 years or older.

    PubMed

    Komase, Yuko; Asako, Akimoto; Kobayashi, Akihiro; Sharma, Raj

    2014-01-01

    In patients receiving inhaled medication, dissatisfaction with and difficulty in using the inhaler can affect treatment adherence. The incidence of handling errors is typically higher in the elderly than in younger people. The aim of the study was to assess inhaler preference for and handling errors with the ELLIPTA® dry powder inhaler (DPI), (GSK), compared with the established BREEZHALER™, a single-dose capsule DPI (Novartis), in inhalation device-naïve Japanese volunteers aged ≥40 years. In this open-label, nondrug interventional, crossover DPI preference study comparing the ELLIPTA DPI and BREEZHALER, 150 subjects were randomized to handle the ELLIPTA or BREEZHALER DPIs until the point of inhalation, without receiving verbal or demonstrative instruction (first attempt). Subjects then crossed over to the other inhaler. Preference was assessed using a self-completed questionnaire. Inhaler handling was assessed by a trained assessor using a checklist. Subjects did not inhale any medication in the study, so efficacy and safety were not measured. The ELLIPTA DPI was preferred to the BREEZHALER by 89% of subjects (odds ratio [OR] 70.14, 95% confidence interval [CI] 33.69-146.01; P-value not applicable for this inhaler) for ease of use, by 63% of subjects (OR 2.98, CI 1.87-4.77; P<0.0001) for ease of determining the number of doses remaining in the inhaler, by 91% for number of steps required, and by 93% for time needed for handling the inhaler. The BREEZHALER was preferred to the ELLIPTA DPI for comfort of the mouthpiece by 64% of subjects (OR 3.16, CI 1.97-5.06; P<0.0001). The incidence of handling errors (first attempt) was 11% with ELLIPTA and 68% with BREEZHALER; differences in incidence were generally similar when analyzed by age (< or ≥65 years) or sex. These data, obtained in an inhalation device-naïve population, suggest that the ELLIPTA DPI is preferred to an established alternative based on its ease-of-use features and is associated with fewer handling errors.

  3. The Pharmaceutical Capping Process-Correlation between Residual Seal Force, Torque Moment, and Flip-off Removal Force.

    PubMed

    Mathaes, Roman; Mahler, Hanns-Christian; Vorgrimler, Lothar; Steinberg, Henrik; Dreher, Sascha; Roggo, Yves; Nieto, Alejandra; Brown, Helen; Roehl, Holger; Adler, Michael; Luemkemann, Joerg; Huwyler, Joerg; Lam, Philippe; Stauch, Oliver; Mohl, Silke; Streubel, Alexander

    2016-01-01

    The majority of parenteral drug products are manufactured in glass vials with an elastomeric rubber stopper and a crimp cap. The vial sealing process is a critical process step during fill-and-finish operations, as it defines the seal quality of the final product. Different critical capping process parameters can affect rubber stopper defects, rubber stopper compression, container closure integrity, and also crimp cap quality. A sufficiently high force to remove the flip-off button prior to usage is required to ensure quality of the drug product unit by the flip-off button during storage, transportation, and until opening and use. Therefore, the final product is 100% visually inspected for lose or defective crimp caps, which is subjective as well as time- and labor-intensive. In this study, we sealed several container closure system configurations with different capping equipment settings (with corresponding residual seal force values) to investigate the torque moment required to turn the crimp cap. A correlation between torque moment and residual seal force has been established. The torque moment was found to be influenced by several parameters, including diameter of the vial head, type of rubber stopper (serum or lyophilized) and type of crimp cap (West(®) or Datwyler(®)). In addition, we measured the force required to remove the flip-off button of a sealed container closure system. The capping process had no influence on measured forces; however, it was possible to detect partially crimped vials. In conclusion, a controlled capping process with a defined target residual seal force range leads to a tight crimp cap on a sealed container closure system and can ensure product quality. The majority of parenteral drug products are manufactured in a glass vials with an elastomeric rubber stopper and a crimp cap. The vial sealing process is a critical process step during fill-and-finish operations, as it defines the seal quality of the final product. An adequate force to remove the flip-off button prior to usage is required to ensure product quality during storage and transportation until use. In addition, the complete crimp cap needs to be fixed in a tight position on the vial. In this study, we investigated the torque moment required to turn the crimp cap and the force required to remove the flip-off button of container closure system sealed with different capping equipment process parameters (having different residual seal force values). © PDA, Inc. 2016.

  4. Methods for Derivation of Inhalation Reference Concentrations and Application of Inhalation Dosimetry

    EPA Pesticide Factsheets

    EPA's methodology for estimation of inhalation reference concentrations (RfCs) as benchmark estimates of the quantitative dose-response assessment of chronic noncancer toxicity for individual inhaled chemicals.

  5. INFLUENCE OF INHALATION INJURY ON ENERGY EXPENDITURE IN SEVERELY BURNED CHILDREN

    PubMed Central

    Przkora, Rene; Fram, Ricki Y.; Herndon, David N.; Suman, Oscar E.; Mlcak, Ronald P.

    2014-01-01

    Objective Determine the effect of inhalation injury on burn-induced hypermetabolism in children. Design Prospective study comparing hypermetabolism (i.e., resting energy expenditure and oxygen consumption) in burned children with and without inhalation injury during acute hospitalization. Setting Single pediatric burn center. Patients Eighty-six children (1–18 years) with ≥ 40% total body surface area burns were stratified to two groups: no inhalation injury and inhalation injury. Interventions None. Main Measurements and Results Inhalation injury was diagnosed based on bronchoscopic evaluation. At admission, PaO2:FiO2 ratios (an index of respiratory distress) were significantly higher in patients with no inhalation injury than in patient with inhalation injury. No differences were detected in resting energy expenditure or percent of the predicted basal metabolic rate between groups. Additionally, oxygen consumption did not significantly differ between groups. Conclusions Inhalation injury does not augment the burn-induced hypermetabolic stress response in children, as reflected by resting energy expenditure and oxygen consumption. PMID:24893760

  6. Oversight Hearings on Asbestos Health Hazards to Schoolchildren. Hearings before the Subcommittee on Elementary, Secondary, and Vocational Education of the Committee on Education and Labor. House of Representatives, Ninety-Sixth Congress, First Session on H.R. 1435 and H.R. 1524 (January 8, 16, and February 22, 1979).

    ERIC Educational Resources Information Center

    Congress of the U.S., Washington, DC. House Committee on Education and Labor.

    Testimony and prepared statements presented during three days of hearings in January and February, 1979, concern the problems of asbestos in school buildings. Medical research indicates that the inhalation of asbestos dust vastly increases a person's chances of contacting fatal diseases such as lung cancer, mesothelioma, and asbestosis. Asbestos…

  7. Comparison of peak inspiratory flow rate via the Breezhaler®, Ellipta® and HandiHaler® dry powder inhalers in patients with moderate to very severe COPD: a randomized cross-over trial.

    PubMed

    Altman, Pablo; Wehbe, Luis; Dederichs, Juergen; Guerin, Tadhg; Ament, Brian; Moronta, Miguel Cardenas; Pino, Andrea Valeria; Goyal, Pankaj

    2018-06-14

    The chronic and progressive nature of chronic obstructive pulmonary disease (COPD) requires self-administration of inhaled medication. Dry powder inhalers (DPIs) are increasingly being used for inhalation therapy in COPD. Important considerations when selecting DPIs include inhalation effort required and flow rates achieved by patients. Here, we present the comparison of the peak inspiratory flow rate (PIF) values achieved by COPD patients, with moderate to very severe airflow limitation, through the Breezhaler®, the Ellipta® and the HandiHaler® inhalers. The effects of disease severity, age and gender on PIF rate were also evaluated. This randomized, open-label, multicenter, cross-over, Phase IV study recruited patients with moderate to very severe airflow limitation (Global Initiative for Obstructive Lung Disease 2014 strategy), aged ≥40 years and having a smoking history of ≥10 pack years. No active drug or placebo was administered during the study. The inhalation profiles were recorded using inhalers fitted with a pressure tap and transducer at the wall of the mouthpiece. For each patient, the inhalation with the highest PIF value, out of three replicate inhalations per device, was selected for analysis. A paired t-test was performed to compare mean PIFs between each combination of devices. In total, 97 COPD patients were enrolled and completed the study. The highest mean PIF value (L/min ± SE) was observed with the Breezhaler® (108 ± 23), followed by the Ellipta® (78 ± 15) and the HandiHaler® (49 ± 9) inhalers and the lowest mean pressure drop values were recorded with the Breezhaler® inhaler, followed by the Ellipta® inhaler and the HandiHaler® inhaler, in the overall patient population. A similar trend was consistently observed in patients across all subgroups of COPD severity, within all age groups and for both genders. Patients with COPD were able to inhale with the least inspiratory effort and generate the highest mean PIF value through the Breezhaler® inhaler when compared with the Ellipta® and the HandiHaler® inhalers. These results were similar irrespective of patients' COPD severity, age or gender. The trial was registered with ClinicalTrials.gov NCT02596009 on 4 November 2015.

  8. Urinary Polycyclic Aromatic Hydrocarbon (OH-PAH) Metabolite Concentrations and the Effect of GST Polymorphisms Among US Air Force Personnel Exposed to Jet Fuel

    PubMed Central

    Rodrigues, Ema G.; Smith, Kristen; Maule, Alexis L.; Sjodin, Andreas; Li, Zheng; Romanoff, Lovisa; Kelsey, Karl; Proctor, Susan; McClean, Michael D.

    2016-01-01

    Objective To evaluate the association between inhalation exposure to jet propulsion fuel 8 (JP-8) and urinary metabolites among US Air Force (USAF) personnel, and investigate the role of glutathione S-transferase polymorphisms. Methods Personal air samples were collected from 37 full-time USAF personnel during 4 consecutive workdays and analyzed for JP-8 constituents and total hydrocarbons. Pre- and postshift urine samples were collected each day and analyzed for polycyclic aromatic hydrocarbon urinary metabolites. Results Work shift exposure to total hydrocarbons was significantly associated with postshift urinary 1-naphthol (β = 0.17; P = <0.0001), 2-naphthol (β = 0.09; P = 0.005), and 2-hydroxyfluorene concentrations (β = 0.08; P = 0.006), and a significant gene-environment interaction was observed with glutathione S-transferase mu-1. Conclusions USAF personnel experience inhalation exposure to JP-8, which is associated with absorption of JP-8 constituents while performing typical job-related tasks, and in our data the glutathione S-transferase mu-1 polymorphism was associated with differential metabolism of naphthalene. PMID:24806557

  9. Urinary polycyclic aromatic hydrocarbon (OH-PAH) metabolite concentrations and the effect of GST polymorphisms among US Air Force personnel exposed to jet fuel.

    PubMed

    Rodrigues, Ema G; Smith, Kristen; Maule, Alexis L; Sjodin, Andreas; Li, Zheng; Romanoff, Lovisa; Kelsey, Karl; Proctor, Susan; McClean, Michael D

    2014-05-01

    To evaluate the association between inhalation exposure to jet propulsion fuel 8 (JP-8) and urinary metabolites among US Air Force (USAF) personnel, and investigate the role of glutathione S-transferase polymorphisms. Personal air samples were collected from 37 full-time USAF personnel during 4 consecutive workdays and analyzed for JP-8 constituents and total hydrocarbons. Pre- and postshift urine samples were collected each day and analyzed for polycyclic aromatic hydrocarbon urinary metabolites. Work shift exposure to total hydrocarbons was significantly associated with postshift urinary 1-naphthol (β = 0.17; P = <0.0001), 2-naphthol (β = 0.09; P = 0.005), and 2-hydroxyfluorene concentrations (β = 0.08; P = 0.006), and a significant gene-environment interaction was observed with glutathione S-transferase mu-1. USAF personnel experience inhalation exposure to JP-8, which is associated with absorption of JP-8 constituents while performing typical job-related tasks, and in our data the glutathione S-transferase mu-1 polymorphism was associated with differential metabolism of naphthalene.

  10. n-Hexane metabolism in occupationally exposed workers.

    PubMed Central

    Mutti, A; Falzoi, M; Lucertini, S; Arfini, G; Zignani, M; Lombardi, S; Franchini, I

    1984-01-01

    Lung uptake and excretion of n-hexane were studied in ten workers in a shoe factory. Simultaneous samples of inhaled and alveolar air were collected with the aid of a Rhan-Otis valve, personal samplers, and charcoal tubes. Alveolar excretion was monitored during a six hour postexposure period. Uptake was calculated from lung ventilation, the retention coefficient, and environmental concentrations. The amount of exhaled n-hexane was calculated from the decay curve. According to the experimental data, alveolar retention was about 25% of the inhaled n-hexane, corresponding to a lung uptake of about 17%. The postexposure alveolar excretion was about 10% of the total uptake. The main metabolites of n-hexane were identified and measured by capillary GC/MS in spot urine samples collected before, at the end, and 15 hours after the same working shift. Urinary concentrations were low, though related to n-hexane in the air. 2,5-Hexanedione in the end of shift samples gave the best estimate of overall exposure. About 3 mg/g creatinine of 2,5-hexanedione would correspond to about 50 ppm of n-hexane in the air (mean daily exposure). PMID:6498115

  11. Design and Computational Fluid Dynamics Investigation of a Personal, High Flow Inhalable Sampler

    PubMed Central

    Anthony, T. Renée; Landázuri, Andrea C.; Van Dyke, Mike; Volckens, John

    2016-01-01

    The objective of this research was to develop an inlet to meet the inhalable sampling criterion at 10 l min−1 flow using the standard, 37-mm cassette. We designed a porous head for this cassette and evaluated its performance using computational fluid dynamics (CFD) modeling. Particle aspiration efficiency was simulated in a wind tunnel environment at 0.4 m s−1 freestream velocity for a facing-the-wind orientation, with sampler oriented at both 0° (horizontal) and 30° down angles. The porous high-flow sampler oriented 30° downward showed reasonable agreement with published mannequin wind tunnel studies and humanoid CFD investigations for solid particle aspiration into the mouth, whereas the horizontal orientation resulted in oversampling. Liquid particles were under-aspirated in all cases, however, with 41–84% lower aspiration efficiencies relative to solid particles. A sampler with a single central 15-mm pore at 10 l min−1 was also investigated and was found to match the porous sampler’s aspiration efficiency for solid particles; the single-pore sampler is expected to be more suitable for liquid particle use. PMID:20418278

  12. Supraventricular tachycardia after fenoterol inhalation: report of two cases.

    PubMed

    Hung, Yu-Fa; Yang, Winnie; Chang, Mei-Ling

    2003-01-01

    Supraventricular tachycardia (SVT) following fenoterol inhalation in metered-dose inhaler (MDI) has never been reported. We report two cases of SVT after fenoterol inhalation in MDI. Case one was a 4-year-old boy who had asthma since early childhood. Paroxysmal supraventricular tachycardia (PSVT) was found after fenoterol inhalation (MDI), which returned to normal sinus rhythm following adenosine injection. The other one was a 9-year-old male who also had asthma since early childhood. He suffered from attacks of PSVT four times after fenoterol inhalation within one year. After verapamil injection and vagal maneuvers, PSVT was converted to normal sinus rhythm. There were no other episodes of SVT after discontinuing usage of fenoterol inhalation for 2 years in the follow-up. We report these two cases to remind pediatricians that cardiac arrhythmias should be evaluated following fenoterol inhalation (MDI).

  13. Evidence for airborne transmission of Norwalk-like virus (NLV) in a hotel restaurant.

    PubMed Central

    Marks, P. J.; Vipond, I. B.; Carlisle, D.; Deakin, D.; Fey, R. E.; Caul, E. O.

    2000-01-01

    An outbreak of gastroenteritis followed a meal in a large hotel during which one of the diners vomited. The clinical features of the illness suggested Norwalk-like virus (NLV, small round structured virus) infection, and this was confirmed by electron microscopy and reverse transcriptase polymerase chain reaction (RT-PCR) of stool samples. Further characterization of the virus by nucleotide sequence analysis of the PCR amplicons revealed identical strains in all the affected individuals. The foods served at the meal could not be demonstrated to be the cause of the outbreak. Analysis of attack rates by dining table showed an inverse relationship with the distance from the person who vomited. No one eating in a separate restaurant reported illness. Transmission from person-to-person or direct contamination of food seems unlikely in this outbreak. However, the findings are consistent with airborne spread of NLV with infection by inhalation with subsequent ingestion of virus particles. PMID:10982072

  14. Household air pollution and personal inhalation exposure to particles (TSP/PM2.5/PM1.0/PM0.25) in rural Shanxi, North China.

    PubMed

    Huang, Ye; Du, Wei; Chen, Yuanchen; Shen, Guofeng; Su, Shu; Lin, Nan; Shen, Huizhong; Zhu, Dan; Yuan, Chenyi; Duan, Yonghong; Liu, Junfeng; Li, Bengang; Tao, Shu

    2017-12-01

    Personal exposure to size-segregated particles among rural residents in Shanxi, China in summer, 2011 were investigated using portable carried samplers (N = 84). Household air pollution was simultaneously studied using stationary samplers in nine homes. Information on household fuel types, cooking activity, smoking behavior, kitchen ventilation conditions etc., were also collected and discussed. The study found that even in the summer period, the daily average concentrations of PM 2.5 and PM 1.0 in the kitchen were as high as 376 ± 573 and 288 ± 397 μg/m 3 (N = 6), that were nearly 3 times of 114 ± 81 and 97 ± 77 μg/m 3 in the bedroom (N = 8), and significantly higher than those of 64 ± 28 and 47 ± 21 μg/m 3 in the outdoor air (N = 6). The personal daily exposure to PM 2.5 and PM 1.0 were 98 ± 52 and 77 ± 47 μg/m 3 , respectively, that were lower than the concentrations in the kitchen but higher than the outdoor levels. The mass fractions of PM 2.5 in TSP were 90%, 72%, 65% and 68% on average in the kitchen, bedroom, outdoor air and personal inhalation exposure, respectively, and moreover, a majority of particles in PM 2.5 had diameters less than 1.0 μm. Calculated time-weighted average exposure based on indoor and outdoor air concentrations and time spent indoor and outdoor were positively correlated but, was ∼33% lower than the directly measured exposure. The daily exposure among those burning traditional solid fuels could be lower by ∼41% if the kitchen was equipped with an outdoor chimney, but was still 8-14% higher than those household using cleaning energies, like electricity and gas. With a ventilator in the kitchen, the exposure among the population using clean energies could be further reduced by 10-24%. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. "...you would probably want to do it. Cause that's what made them popular": Exploring perceptions of inhalant utility among young adolescent nonusers and occasional users.

    PubMed

    Siegel, Jason T; Alvaro, Eusebio M; Patel, Neil; Crano, William D

    2009-01-01

    With an eye toward future primary prevention efforts, this study explores perceptions of inhalant utility among young adolescents in the United States. The study makes use of data gathered via nine focus groups conducted in Tucson, Arizona in 2004 (N = 47, mean age = 13.2 years). Three main themes emerged concerning the perceived utility of inhalant use: (1) Inhalant use as a means of mental escape, (2) Inhalant use as a social tool, and (3) Inhalant use as a parental relations tool. Additionally, participants discussed an interaction hypothesis regarding inhalant use and popularity. Implications for future research are suggested and limitations described.

  16. 49 CFR 172.400 - General labeling requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 172.411 1.6 EXPLOSIVES 1.6 172.411 2.1 FLAMMABLE GAS 172.417 2.2 NONFLAMMABLE GAS 172.415 2.3 POISON...)) POISON INHALATION HAZARD 172.429 6.1(other than material poisonous by inhalation) POISON 172.430 6.1 (inhalation hazard, Zone A or B) POISON INHALATION HAZARD 172.429 6.1 (other than inhalation hazard, Zone A or...

  17. 49 CFR 172.400 - General labeling requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 172.411 1.6 EXPLOSIVES 1.6 172.411 2.1 FLAMMABLE GAS 172.417 2.2 NONFLAMMABLE GAS 172.415 2.3 POISON...)) POISON INHALATION HAZARD 172.429 6.1(other than material poisonous by inhalation) POISON 172.430 6.1 (inhalation hazard, Zone A or B) POISON INHALATION HAZARD 172.429 6.1 (other than inhalation hazard, Zone A or...

  18. 49 CFR 172.400 - General labeling requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 172.411 1.6 EXPLOSIVES 1.6 172.411 2.1 FLAMMABLE GAS 172.417 2.2 NONFLAMMABLE GAS 172.415 2.3 POISON...)) POISON INHALATION HAZARD 172.429 6.1(other than material poisonous by inhalation) POISON 172.430 6.1 (inhalation hazard, Zone A or B) POISON INHALATION HAZARD 172.429 6.1 (other than inhalation hazard, Zone A or...

  19. 49 CFR 172.400 - General labeling requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 172.411 1.6 EXPLOSIVES 1.6 172.411 2.1 FLAMMABLE GAS 172.417 2.2 NONFLAMMABLE GAS 172.415 2.3 POISON...)) POISON INHALATION HAZARD 172.429 6.1(other than material poisonous by inhalation) POISON 172.430 6.1 (inhalation hazard, Zone A or B) POISON INHALATION HAZARD 172.429 6.1 (other than inhalation hazard, Zone A or...

  20. 49 CFR 172.400 - General labeling requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 172.411 1.6 EXPLOSIVES 1.6 172.411 2.1 FLAMMABLE GAS 172.417 2.2 NONFLAMMABLE GAS 172.415 2.3 POISON...)) POISON INHALATION HAZARD 172.429 6.1(other than material poisonous by inhalation) POISON 172.430 6.1 (inhalation hazard, Zone A or B) POISON INHALATION HAZARD 172.429 6.1 (other than inhalation hazard, Zone A or...

Top