Sample records for c18 solid-phase extraction

  1. Determination of the Antibiotic Oxytetracycline in Commercial Milk by Solid-Phase Extraction: A High-Performance Liquid Chromatography (HPLC) Experiment for Quantitative Instrumental Analysis

    ERIC Educational Resources Information Center

    Mei-Ratliff, Yuan

    2012-01-01

    Trace levels of oxytetracylcine spiked into commercial milk samples are extracted, cleaned up, and preconcentrated using a C[subscript 18] solid-phase extraction column. The extract is then analyzed by a high-performance liquid chromatography (HPLC) instrument equipped with a UV detector and a C[subscript 18] column (150 mm x 4.6 mm x 3.5 [mu]m).…

  2. Analysis of trifluralin, methyl paraoxon, methyl parathion, fenvalerate and 2,4-D dimethylamine in pond water using solid-phase extraction

    USGS Publications Warehouse

    Swineford, D.M.; Belisle, A.A.

    1989-01-01

    A method was developed for the simultaneous extraction of trifluralin, methyl paraoxon, methyl parathion, fenvalerate, and 2,4-D dimethylamine salt in pond water using a solid-phase C18 column. After elution from the C18 column, the eluate was analyzed on a capillary gas chromatograph equipped with an electron-capture or flame photometric detector.

  3. Molecularly imprinted solid-phase extraction sorbent for the clean-up of chlorinated phenoxyacids from aqueous samples.

    PubMed

    Baggiani, C; Giovannoli, C; Anfossi, L; Tozzi, C

    2001-12-14

    A molecularly imprinted polymer (MIP) was synthesized using the herbicide 2,4,5-trichlorophenoxyacetic acid as a template, 4-vinylpyridine as an interacting monomer, ethylendimethacrylate as a cross-linker and a methanol-water mixture as a porogen. The binding properties and the selectivity of the polymer towards the template were investigated by frontal and zonal liquid chromatography. The polymer was used as a solid-phase extraction material for the clean-up of the template molecule and some related herbicides (2,4-dichlorophenoxyacetic acid, fenoprop, dichlorprop) from river water samples at a concentration level of ng/ml with quantitative recoveries comparable with those obtained with a traditional C18 reversed-phase column when analyzed by capillary electrophoresis. The results obtained show that the MIP-based approach to the solid-phase extraction is comparable with the more traditional solid-phase extraction with C18 reversed-phase columns in terms of recovery, but it is superior in terms of sample clean-up.

  4. Development and Validation of HPLC Method for Determination of Crocetin, a constituent of Saffron, in Human Serum Samples.

    PubMed

    Mohammadpour, Amir Hooshang; Ramezani, Mohammad; Tavakoli Anaraki, Nasim; Malaekeh-Nikouei, Bizhan; Amel Farzad, Sara; Hosseinzadeh, Hossein

    2013-01-01

    The present study reports the development and validation of a sensitive and rapid extraction method beside high performance liquid chromatographic method for the determination of crocetin in human serum. The HPLC method was carried out by using a C18 reversed-phase column and a mobile phase composed of methanol/water/acetic acid (85:14.5:0.5 v/v/v) at the flow rate of 0.8 ml/min. The UV detector was set at 423 nm and 13-cis retinoic acid was used as the internal standard. Serum samples were pretreated with solid-phase extraction using Bond Elut C18 (200mg) cartridges or with direct precipitation using acetonitrile. The calibration curves were linear over the range of 0.05-1.25 µg/ml for direct precipitation method and 0.5-5 µg/ml for solid-phase extraction. The mean recoveries of crocetin over a concentration range of 0.05-5 µg/ml serum for direct precipitation method and 0.5-5 µg/ml for solid-phase extraction were above 70 % and 60 %, respectively. The intraday coefficients of variation were 0.37- 2.6% for direct precipitation method and 0.64 - 5.43% for solid-phase extraction. The inter day coefficients of variation were 1.69 - 6.03% for direct precipitation method and 5.13-12.74% for solid-phase extraction, respectively. The lower limit of quantification for crocetin was 0.05 µg/ml for direct precipitation method and 0.5 µg/ml for solid-phase extraction. The validated direct precipitation method for HPLC satisfied all of the criteria that were necessary for a bioanalytical method and could reliably quantitate crocetin in human serum for future clinical pharmacokinetic study.

  5. Development and Validation of HPLC Method for Determination of Crocetin, a constituent of Saffron, in Human Serum Samples

    PubMed Central

    Mohammadpour, Amir Hooshang; Ramezani, Mohammad; Tavakoli Anaraki, Nasim; Malaekeh-Nikouei, Bizhan; Amel Farzad, Sara; Hosseinzadeh, Hossein

    2013-01-01

    Objective(s): The present study reports the development and validation of a sensitive and rapid extraction method beside high performance liquid chromatographic method for the determination of crocetin in human serum. Materials and Methods: The HPLC method was carried out by using a C18 reversed-phase column and a mobile phase composed of methanol/water/acetic acid (85:14.5:0.5 v/v/v) at the flow rate of 0.8 ml/min. The UV detector was set at 423 nm and 13-cis retinoic acid was used as the internal standard. Serum samples were pretreated with solid-phase extraction using Bond Elut C18 (200mg) cartridges or with direct precipitation using acetonitrile. Results: The calibration curves were linear over the range of 0.05-1.25 µg/ml for direct precipitation method and 0.5-5 µg/ml for solid-phase extraction. The mean recoveries of crocetin over a concentration range of 0.05-5 µg/ml serum for direct precipitation method and 0.5-5 µg/ml for solid-phase extraction were above 70 % and 60 %, respectively. The intraday coefficients of variation were 0.37- 2.6% for direct precipitation method and 0.64 - 5.43% for solid-phase extraction. The inter day coefficients of variation were 1.69 – 6.03% for direct precipitation method and 5.13-12.74% for solid-phase extraction, respectively. The lower limit of quantification for crocetin was 0.05 µg/ml for direct precipitation method and 0.5 µg/ml for solid-phase extraction. Conclusion: The validated direct precipitation method for HPLC satisfied all of the criteria that were necessary for a bioanalytical method and could reliably quantitate crocetin in human serum for future clinical pharmacokinetic study. PMID:23638292

  6. Simultaneous analysis of hydrochlorothiazide, triamterene and reserpine in rat plasma by high performance liquid chromatography and tandem solid-phase extraction.

    PubMed

    Li, Hang; He, Junting; Liu, Qin; Huo, Zhaohui; Liang, Si; Liang, Yong

    2011-03-01

    A tandem solid-phase extraction method (SPE) of connecting two different cartridges (C(18) and MCX) in series was developed as the extraction procedure in this article, which provided better extraction yields (>86%) for all analytes and more appropriate sample purification from endogenous interference materials compared with a single cartridge. Analyte separation was achieved on a C(18) reversed-phase column at the wavelength of 265 nm by high-performance liquid chromatography (HPLC). The method was validated in terms of extraction yield, precision and accuracy. These assays gave mean accuracy values higher than 89% with RSD values that were always less than 3.8%. The method has been successfully applied to plasma samples from rats after oral administration of target compounds. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Agarose-chitosan-C18 film micro-solid phase extraction combined with high performance liquid chromatography for the determination of phenanthrene and pyrene in chrysanthemum tea samples.

    PubMed

    Ng, Nyuk Ting; Sanagi, Mohd Marsin; Wan Ibrahim, Wan Nazihah; Wan Ibrahim, Wan Aini

    2017-05-01

    Agarose-chitosan-immobilized octadecylsilyl-silica (C 18 ) film micro-solid phase extraction (μSPE) was developed and applied for the determination of phenanthrene (PHE) and pyrene (PYR) in chrysanthemum tea samples using high performance liquid chromatography-ultraviolet detection (HPLC-UV). The film of blended agarose and chitosan allows good dispersion of C 18 , prevents the leaching of C 18 during application and enhances the film mechanical stability. Important μSPE parameters were optimized including amount of sorbent loading, extraction time, desorption solvent and desorption time. The matrix match calibration curves showed good linearity (r⩾0.994) over a concentration range of 1-500ppb. Under the optimized conditions, the proposed method showed good limits of detection (0.549-0.673ppb), good analyte recoveries (100.8-105.99%) and good reproducibilities (RSDs⩽13.53%, n=3) with preconcentration factors of 4 and 72 for PHE and PYR, respectively. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. [Determination of patulin in fruits and jam by solid phase extraction-ultra performance liquid chromatography].

    PubMed

    Lü, Weichao; Shen, Shuchang; Wang, Chao

    2017-11-08

    With magnesium silicate, silica gel, diatomite and calcium sulfate as raw materials, a new solid phase extraction column was prepared through a series of processes of grinding to ethanol homogenate, drying and packing into polypropylene tube. The sample was hydrolyzed by pectinase, extracted by acetonitrile and purified by solid phase extraction. The target compounds were separated on a C18 column (100 mm×2.1 mm, 1.8 μm), using 0.8% (v/v) tetrahydrofuran solution as mobile phase with a flow rate of 0.5 mL/min. The detection wavelength was 276 nm. The effect of pectinase on extraction yield and purification effect of solid-phase extraction column were investigated. The optimum chromatographic conditions were selected. There was a good linear relationship between the peak heights and the mass concentrations of patulin in the range of 0.1 to 10 mg/L with the correlation coefficient ( R 2 ) of 1. The limit of detection for this method was 10.22 μg/kg. The spiked recoveries of samples were 86.58%-94.84% with the relative standard deviations (RSDs) of 1.45%-2.28%. The results indicated that the self-made solid phase extraction column had a good purification efficiency, and the UPLC had a high separation efficiency. The method is simple, accurate and of great significance for the quality and safety control of fruit products.

  9. Determination of azoxystrobin residues in grapes, musts and wines with a multicommuted flow-through optosensor implemented with photochemically induced fluorescence.

    PubMed

    Flores, Javier López; Díaz, Antonio Molina; Fernández de Córdova, María L

    2007-02-28

    In this paper, the conversion of azoxystrobin in a strongly fluorescent degradation product by UV irradiation with quantitative purposes and its fluorimetric determination are reported for the first time. A multicommuted flow injection-solid phase spectroscopy (FI-SPS) system combined with photochemically-induced fluorescence (PIF) is developed for the determination of azoxystrobin in grapes, must and wine. Grape samples were homogenized and extracted with methanol and further cleaned-up by solid-phase extraction on C(18) silica gel. Wine samples were solid-phase extracted on C(18) sorbent using dichloromethane as eluent. Recoveries of azoxystrobin from spiked grapes (0.5-2.0 mg Kg(-1)), must (0.5-2.0 microg mL(-1)) and wine (0.5-2.0 microg mL(-1)) were 84.0-87.6%, 95.5-105.9% and 88.5-111.2%, respectively. The quantification limit for grapes was 0.021 mg Kg(-1), being within European Union regulations, and 18 microg L(-1) and 8 microg L(-1) for must and wine, respectively.

  10. Two-dimensional solid-phase extraction strategy for the selective enrichment of aminoglycosides in milk.

    PubMed

    Shen, Aijin; Wei, Jie; Yan, Jingyu; Jin, Gaowa; Ding, Junjie; Yang, Bingcheng; Guo, Zhimou; Zhang, Feifang; Liang, Xinmiao

    2017-03-01

    An orthogonal two-dimensional solid-phase extraction strategy was established for the selective enrichment of three aminoglycosides including spectinomycin, streptomycin, and dihydrostreptomycin in milk. A reversed-phase liquid chromatography material (C 18 ) and a weak cation-exchange material (TGA) were integrated in a single solid-phase extraction cartridge. The feasibility of two-dimensional clean-up procedure that experienced two-step adsorption, two-step rinsing, and two-step elution was systematically investigated. Based on the orthogonality of reversed-phase and weak cation-exchange procedures, the two-dimensional solid-phase extraction strategy could minimize the interference from the hydrophobic matrix existing in traditional reversed-phase solid-phase extraction. In addition, high ionic strength in the extracts could be effectively removed before the second dimension of weak cation-exchange solid-phase extraction. Combined with liquid chromatography and tandem mass spectrometry, the optimized procedure was validated according to the European Union Commission directive 2002/657/EC. A good performance was achieved in terms of linearity, recovery, precision, decision limit, and detection capability in milk. Finally, the optimized two-dimensional clean-up procedure incorporated with liquid chromatography and tandem mass spectrometry was successfully applied to the rapid monitoring of aminoglycoside residues in milk. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. [Simultaneous determination of 15 industrial synthetic dyes in condiment by solid phase extraction-high performance liquid chromatography].

    PubMed

    Liu, Min; Li, Xiaolin; Bie, Wei; Wang, Minglin; Feng, Qian

    2011-02-01

    A new method was established for the determination of 15 industrial synthetic dyes in condiment by solid phase extraction-high performance liquid chromatography (SPE-HPLC). The samples were extracted by methanol-water (1:1, v/v) and purified by a solid phase extraction column. Then, the chromatographic separation was achieved on a Luna C18 column by linear gradient elution. The mobile phase was 10 mmol/L ammonium acetate-acetonitrile (containing 1% acetic acid). The results showed that the 15 industrial synthetic dyes can be separated efficiently. The recoveries of the 15 industrial synthetic dyes spiked in condiment were between 84.6% and 114.2% with the relative standard deviations of 0.9% - 10.3%. The limits of detection of this method was 0.05 - 0.18 mg/kg for the 15 industrial synthetic dyes. The method is simple, sensitive, accurate, repeatable and can be used for simultaneous determination of the 15 illegally added industrial synthetic dyes.

  12. Facile purification and click labeling with 2-[ 18F]fluoroethyl azide using solid phase extraction cartridges

    DOE PAGES

    Zhou, Dong; Chu, Wenhua; Peng, Xin; ...

    2014-11-04

    In this paper, a facile method was developed to purify 2-[ 18F]fluoroethyl azide ([ 18F]FEA) using a C18 cartridge and an Oasis® HLB cartridge in series, in which [18F]FEA was exclusively trapped on the HLB cartridge. [ 18F]FEA can be eluted for reactions in solution; alternatively click labeling can be carried out on the HLB cartridge itself by loading an alkyne substrate and copper (I) catalyst dissolved in DMF onto the cartridge. Finally, this solid phase extraction methodology for purification and click labeling with [ 18F]FEA, either in solution or on the cartridge, is safe, simple, reproducible in high yield,more » and compatible with automated synthesis of 18F-labeled PET tracers.« less

  13. Magnetic solid-phase extraction and determination of puerarin in rat plasma using C(18)-functionalized magnetic silica nanoparticles by high performance liquid chromatography.

    PubMed

    Wang, Qi; Huang, Lijie; Yu, Panfeng; Wang, Jianchang; Shen, Shun

    2013-01-01

    In the paper, we presented a magnetic solid-phase extraction (MSPE) method based on C(18)-functionalized magnetic silica nanoparticles for the analysis of puerarin in rat plasma. The approach involves two steps including synthesis of magnetic solid-phase sorbents and bioanalysis. The synthesized magnetic silica microspheres modified with chloro(dimethyl)octylsilane (namely Fe(3)O(4)@SiO(2)-C(18)) can provide an efficient way for the extraction of puerarin through C(18) hydrophobic interaction. The puerarin could be easily enriched using milligram-level Fe(3)O(4)@SiO(2)-C(18) sorbents with vibration for 10min. By means of a magnet, puerarin adsorbed with Fe(3)O(4)@SiO(2)-C(18) sorbents was easily isolated from the matrix, and desorbed with CAN. No carryover was observed, and the sorbents could be recycled in our study. The method recoveries were obtained from 85.2% to 92.3%. Limits of quantification and limits of detection of 0.1μgmL(-1) and 0.05μgmL(-1), respectively were achieved. The precision was from 8.1 to 13.7% for intra-day measurement, and from 9.4 to 15.2% for inter-day variation. The accuracy ranged from 94.7 to 106.3% for intra-day measurement, and from 93.3 to 107.8% for inter-day measurement. The MSPE method was applied for analysis of puerarin in rat plasma samples. The results indicated that it was convenient and efficient for the determination of puerarin in biosamples. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Mixed-mode isolation of triazine metabolites from soil and aquifer sediments using automated solid-phase extraction

    USGS Publications Warehouse

    Mills, M.S.; Thurman, E.M.

    1992-01-01

    Reversed-phase isolation and ion-exchange purification were combined in the automated solid-phase extraction of two polar s-triazine metabolites, 2-amino-4-chloro-6-(isopropylamino)-s-triazine (deethylatrazine) and 2-amino-4-chloro-6-(ethylamino)-s-triazine (deisopropylatrazine) from clay-loam and slit-loam soils and sandy aquifer sediments. First, methanol/ water (4/1, v/v) soil extracts were transferred to an automated workstation following evaporation of the methanol phase for the rapid reversed-phase isolation of the metabolites on an octadecylresin (C18). The retention of the triazine metabolites on C18 decreased substantially when trace methanol concentrations (1%) remained. Furthermore, the retention on C18 increased with decreasing aqueous solubility and increasing alkyl-chain length of the metabolites and parent herbicides, indicating a reversed-phase interaction. The analytes were eluted with ethyl acetate, which left much of the soil organic-matter impurities on the resin. Second, the small-volume organic eluate was purified on an anion-exchange resin (0.5 mL/min) to extract the remaining soil pigments that could foul the ion source of the GC/MS system. Recoveries of the analytes were 75%, using deuterated atrazine as a surrogate, and were comparable to recoveries by soxhlet extraction. The detection limit was 0.1 ??g/kg with a coefficient of variation of 15%. The ease and efficiency of this automated method makes it viable, practical technique for studying triazine metabolites in the environment.

  15. Simultaneous determination of all-trans and 13-cis retinoic acids and their 4-oxo metabolites by adsorption liquid chromatography after solid-phase extraction.

    PubMed

    Lefebvre, P; Agadir, A; Cornic, M; Gourmel, B; Hue, B; Dreux, C; Degos, L; Chomienne, C

    1995-04-07

    All-trans retinoic acid (all-trans RA), the active metabolite of vitamin A, has been demonstrated to be an efficient alternative to chemotherapy in the treatment of acute promyelocytic leukemia (APL), the AML3 subtype of the FAB cytological classification. Complete remission is obtained by inducing terminal granulocytic differentiation of the leukemic cells. To study all-trans RA pharmacokinetics in patients with APL, a rapid, precise and selective high-performance liquid chromatographic (HPLC) assay was developed. This method is easy and shows good repeatability (C.V. = 8.41-12.44%), reproducibility (C.V. = 9.19-14.73%), accuracy (C.V. = 3.5-11%) and sensitivity with a detection limit of 5 pmol/ml. The analysis is performed using normal-phase HPLC in an isocratic mode with UV detection after solid-phase extraction on octadecyl (C18) columns. The mobile phase is hexane-dichloromethane-dioxane (78:18:4, v/v) containing 1% acetic acid.

  16. Preparation of C₁₈-functionalized magnetic polydopamine microspheres for the enrichment and analysis of alkylphenols in water samples.

    PubMed

    Wang, Xianying; Deng, Chunhui

    2016-02-01

    In this work, C18-functionalized magnetic polydopamine microspheres (Fe3O4@PDA@C18) were successfully synthesized and applied to the analysis of alkylphenols in water samples. The magnetic Fe3O4 particles coated with hydrophilic surface were synthesized via a solvothermal reaction and the self-polymerization of dopamine. And then the C18 groups were fabricated by a silylanization method. Benefit from the merits of Fe3O4 particles, polydopamine coating and C18 groups, the Fe3O4@PDA@C18 material possessed several properties of super magnetic responsiviness, good water dispersibility, π-electron system and hydrophobic C18 groups. Thus, the materials had great potential to be developed as the adsorbent for the magnetic solid-phase extraction (MSPE) technique. Here, we selected three kinds of alkylphenols (4-tert-octylphenol, 4-n-nonylphenol, 4-n-octylphenol) to be the target analyst for evaluating the performance of the prepared material. In this study, various extraction parameters were investigated and optimized, such as pH values of water sample solution, amount of adsorbents, adsorption and desorption time, the species of desorption solution. Meanwhile, the method validations were studied, including linearity, limit of detection and method precision. From the results, Fe3O4@PDA@C18 composites were successfully applied as the adsorbents for the extraction of alkylphenols in water samples. The proposed material provided an approach for a simple, rapid magnetic solid-phase extraction for hydrophobic compounds in environmental samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Simultaneous determination of four trace estrogens in feces, leachate, tap and groundwater using solid-liquid extraction/auto solid-phase extraction and high-performance liquid chromatography with fluorescence detection.

    PubMed

    Liu, Na; Shi, Yue-e; Li, Mengyan; Zhang, Ting-di; Gao, Song

    2015-10-01

    A simple and selective high-performance liquid chromatography method coupled with fluorescence detection was developed for the simultaneous measurement of trace levels of four estrogens (estrone, estradiol, estriol and 17α-ethynyl estradiol) in environmental matrices. For feces samples, solid-liquid extraction was applied with a 1:1 v/v mixture of acetonitrile and ethyl acetate as the extraction solvent. For liquid samples (e.g., leachate and groundwater), hydrophobic/lipophilic balanced automated solid-phase extraction disks were selected due to their high recoveries compared to conventional C18 disks. Chromatographic separations were performed on a reversed-phase C18 column gradient-eluted with a 45:55 v/v mixture of acetonitrile and water. The detection limits were down to 1.1 × 10(-2) (estrone), 4.11 × 10(-4) (estradiol), 5.2 × 10(-3) (estriol) and 7.18 × 10(-3) μg/L (17α-ethynyl estradiol) at excitation/emission wavelengths of 288/310 nm, with recoveries in the range of 96.9 ± 3.2-105.4 ± 3.2% (n = 3). The method was successfully applied to determine estrogens in feces and water samples collected at livestock farms and a major river in Northeast China. We observed relatively high abundance and widespread distribution of all four estrogens in our sample collections, implying the urgency for a comprehensive and intricate investigation of estrogenic fate and contamination in our researched area. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Application of a hybrid ordered mesoporous silica as sorbent for solid-phase multi-residue extraction of veterinary drugs in meat by ultra-high-performance liquid chromatography coupled to ion-trap tandem mass spectrometry.

    PubMed

    Casado, Natalia; Morante-Zarcero, Sonia; Pérez-Quintanilla, Damián; Sierra, Isabel

    2016-08-12

    A quick, sensitive and selective analytical reversed-phase multi-residue method using ultra-high performance liquid chromatography coupled to an ion-trap mass spectrometry detector (UHPLC-IT-MS/MS) operating in both positive and negative ion mode was developed for the simultaneous determination of 23 veterinary drug residues (β-blockers, β-agonists and Non-Steroidal Anti-inflammatory Drugs (NSAIDs)) in meat samples. The sample treatment involved a liquid-solid extraction followed by a solid-phase extraction (SPE) procedure. SBA-15 type mesoporous silica was synthetized and modified with octadecylsilane, and the resulting hybrid material (denoted as SBA-15-C18) was applied and evaluated as SPE sorbent in the purification of samples. The materials were comprehensively characterized, and they showed a high surface area, high pore volume and a homogeneous distribution of the pores. Chromatographic conditions and extraction procedure were optimized, and the method was validated according to the Commission Decision 2002/657/EC. The method detection limits (MDLs) and the method quantification limits (MQLs) were determined for all the analytes in meat samples and found to range between 0.01-18.75μg/kg and 0.02-62.50μg/kg, respectively. Recoveries for 15 of the target analytes ranged from 71 to 98%. In addition, for comparative purpose SBA-15-C18 was evaluated towards commercial C18 amorphous silica. Results revealed that SBA-15-C18 was clearly more successful in the multi-residue extraction of the 23 mentioned analytes with higher recovery values. The method was successfully tested to analyze prepacked preparations of mince bovine meat. Traces of propranolol, ketoprofen and diclofenac were detected in some samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. EVALUATION OF ANDROSTENEDIONE AS AN ANDROGENIC COMPONENT OF RIVER WATER DOWNSTREAM OF A PULP AND PAPER MILL EFFLUENT

    EPA Science Inventory

    This study evaluates a recent report indicating that androstenedione contributes to the androgenicity of water downstream of a pulp and paper mill discharge on the Fenholloway River, Florida, USA. Extraction and concentration of Fenholloway water with C18 solid phase extraction c...

  20. Liquid-liquid and solid-phase extractions of phenols from virgin olive oil and their separation by chromatographic and electrophoretic methods.

    PubMed

    Bendini, Alessandra; Bonoli, Matteo; Cerretani, Lorenzo; Biguzzi, Barbara; Lercker, Giovanni; Toschi, Tullia Gallina

    2003-01-24

    The high oxidative stability of virgin olive oil is related to its high monounsaturated/polyunsaturated ratio and to the presence of antioxidant compounds, such as tocopherols and phenols. In this paper, the isolation of phenolic compounds from virgin olive oil, by different methods, was tested and discussed. Particularly liquid-liquid and solid-phase extraction methods were compared, assaying, for the latter, three stationary phases (C8, C18 and Diol) and several elution mixtures. Quantification of phenolic and o-diphenolic substances in the extracts was performed by the traditional Folin-Ciocalteau method and the sodium molybdate reaction, respectively. Furthermore, the quantification of phenolic compounds in the extracts and in a standard mixture was carried out both with diode array and mass spectrometric detection and capillary zone electrophoresis.

  1. Simultaneous Determination of Perfluorinated Compounds in Edible Oil by Gel-Permeation Chromatography Combined with Dispersive Solid-Phase Extraction and Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Yang, Lili; Jin, Fen; Zhang, Peng; Zhang, Yanxin; Wang, Jian; Shao, Hua; Jin, Maojun; Wang, Shanshan; Zheng, Lufei; Wang, Jing

    2015-09-30

    A simple analytical method was developed for the simultaneous analysis of 18 perfluorinated compounds (PFCs) in edible oil. The target compounds were extracted by acetonitrile, purified by gel permeation chromatography (GPC) and dispersive solid-phase extraction (DSPE) using graphitized carbon black (GCB) and octadecyl (C18), and analyzed by liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ES-MS/MS) in negative ion mode. Recovery studies were performed at three fortification levels. The average recoveries of all target PFCs ranged from 60 to 129%, with an acceptable relative standard deviation (RSD) (1-20%, n = 3). The method detection limits (MDLs) ranged from 0.004 to 0.4 μg/kg, which was significantly improved compared with the existing liquid-liquid extraction and cleanup method. The method was successfully applied for the analysis of all target PFCs in edible oil samples collected from markets in Beijing, China, and the results revealed that C6-C10 perfluorocarboxylic acid (PFCAs) and C7 perfluorosulfonic acid PFSAs were the major PFCs detected in oil samples.

  2. Simultaneous determination of azathioprine and 6-mercaptopurine by high-performance liquid chromatography.

    PubMed

    Van Os, E C; McKinney, J A; Zins, B J; Mays, D C; Schriver, Z H; Sandborn, W J; Lipsky, J J

    1996-04-26

    A specific, sensitive, single-step solid-phase extraction and reversed-phase high-performance liquid chromatographic method for the simultaneous determination of plasma 6-mercaptopurine and azathioprine concentrations is reported. Following solid-phase extraction, analytes are separated on a C18 column with mobile phase consisting of 0.8% acetonitrile in 1 mM triethylamine, pH 3.2, run on a gradient system. Quantitation limits were 5 ng/ml and 2 ng/ml for azathioprine and 6-mercaptopurine, respectively. Peak heights correlated linearly to known extracted standards for 6-mercaptopurine and azathioprine (r = 0.999) over a range of 2-200 ng/ml. No chromatographic interferences were detected.

  3. Determination of six pesticides in the medicinal herb Cordia salicifolia by matrix solid-phase dispersion and gas chromatography/mass spectrometry.

    PubMed

    de Carvalho, Pedro Henrique Viana; Prata, Vanessa de Menezes; Alves, Péricles Barreto; Navickiene, Sandro

    2009-01-01

    A simple and effective extraction method based on matrix solid-phase dispersion was developed for acephate, chlorpropham, pyrimicarb, bifenthrin, tetradifon, and phosalone in leaves of the medicinal plant Cordia salicifolia, whose extracts are commercialized in Brazil as diuretic, appetite suppressant, and weight loss products. The determination method was GC/MS with selected-ion monitoring. Different parameters of the method were evaluated, such as type of solid phase (C18, alumina, silica gel, and Florisil) and the amount of solid phase and eluent (dichloromethane, ethyl acetate, chloroform, and cyclohexane). The best results were obtained using 0.5 g herb sample, 0.5 g neutral alumina as the dispersant sorbent, 0.5 g C18 as the cleanup sorbent, and cyclohexane-dichloromethane (3 + 1, v/v) as the eluting solvent. The method was validated using herb samples fortified with pesticides at different concentration levels (0.3, 0.5, and 1.0 mg/kg). Average recoveries (seven replicates) ranged from 67.7 to 129.9%, with relative standard deviations between 6.3 and 26%. Detection and quantitation limits for the herb ranged from 0.10 to 0.15 and 0.15 to 0.25 mg/kg, respectively.

  4. One-pot synthesized functionalized mesoporous silica as a reversed-phase sorbent for solid-phase extraction of endocrine disrupting compounds in milks.

    PubMed

    Gañán, Judith; Morante-Zarcero, Sonia; Pérez-Quintanilla, Damián; Marina, María Luisa; Sierra, Isabel

    2016-01-08

    A new procedure for the determination of 12 naturally occurring hormones and some related synthetic chemicals in milk, commonly used as growth promoters in cattle, is reported. The method is based on liquid-liquid extraction followed by solid-phase extraction (SPE) using a new one-pot synthesized ordered mesoporous silica (of the SBA-15 type) functionalized with octadecyl groups (denoted as SBA-15-C18-CO) as reversed-phase sorbent. The analytes were eluted with methanol and then submitted to HPLC with diode array detection. Under optimal conditions, the method quantification limit for the analytes ranged from 0.023 to 1.36μg/mL. The sorbent affored the extraction of estrone, 17β-estradiol, estriol, progesterone, hexestrol, diethylstilbestrol, 4-androstene-3,17-dione, ethinylestradiol, 17α-methyltestosterone, nandrolone, prednisolone and testosterone with mean recoveries ranging from 72% to 105% (except for diethylstilbestrol) with RSD<11%. These results were comparable and, in some cases, even better than those obtained with other extraction methods, therefore SBA-15-C18-CO mesoporous silica possess a high potential as a reversed-phase sorbent for SPE of the 12 mentioned endocrine disrupting compounds in milk samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Solid phase extraction and spectrophotometric determination of Au(III) with 5-(2-hydroxy-5-nitrophenylazo)thiorhodanine.

    PubMed

    Hu, Qiufen; Chen, Xiubin; Yang, Xiangjun; Huang, Zhangjie; Chen, Jing; Yang, Guangyu

    2006-04-01

    A new chromogenic reagent, 5-(2-hydroxy-5-nitrophenylazo)thiorhodanine (HNATR) was synthesized. A highly sensitive, selective and rapid method for the determination microg l(-1) level of Au(III) based on the rapid reaction of Au(III) with HNATR and the solid phase extraction of the colored complex with a reversed phase polymer-based C(18) cartridge have been developed. The HNATR reacted with Au(III) to form a red complex of a molar ratio 1:2 (Au(III) to HNATR) in the presence of 0.05 - 0.5 mol l(-1) of phosphoric acid solution and emulsifier-OP medium. This complex was enriched by the solid phase extraction with a polymer-based C(18) cartridge. The enrichment factor of 100 was achieved. The molar absorptivity of the complex is 1.37 x 10(5) l mol(-1) cm(-1) at 520 nm in the measured solution. The system obeys Beer's law in the range of 0.01 - 3 microg ml(-1). The relative standard deviation for eleven replicates sample of 0.5 microg l(-1) level is 2.18%. The detection limit, based on the three times of standard deviation is 0.02 microg l(-1) in the original sample. This method was applied to the determination of gold in water and ore with good results.

  6. Determination of flubendiamide in honey at trace levels by using solid phase extraction and liquid chromatography coupled to quadrupole time-of-flight mass spectrometry.

    PubMed

    Ares, Ana M; Valverde, Silvia; Bernal, José L; Toribio, Laura; Nozal, María J; Bernal, José

    2017-10-01

    In this study, a new method has been developed to determine flubendiamide in honey using liquid chromatography coupled to a selective mass spectrometry detector (quadrupole-time-of-flight). An efficient sample treatment involving a solid phase extraction with a C 18 sorbent was proposed (average analyte recoveries were between 94 and 104%). Chromatographic analysis (9min) was performed on a C 18 column (Gemini C 18 , 50×2.0mm, 3µm, 110Å). The mobile phase consisted of water and acetonitrile, with a flow rate of 0.5mL/min in gradient elution mode. The method was fully validated in terms of selectivity, limits of detection and quantification, matrix effect, linearity, trueness and precision. Low limits of detection and quantification were obtained, ranging from 0.1 to 0.2µg/kg and 0.4 to 0.6µg/kg, respectively. The method was applied to analyze flubendiamide in honey from different botanic origins (multifloral, rosemary and heather). Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Dispersive solid-phase extraction followed by high-performance liquid chromatography/tandem mass spectrometry for the determination of ricinine in cooking oil.

    PubMed

    Cai, Meiqiang; Chen, Xiaohong; Wei, Xiaoqing; Pan, Shengdong; Zhao, Yonggang; Jin, Micong

    2014-09-01

    A rapid and accurate method by liquid chromatography/tandem mass spectrometry (LC-MS/MS) using positive electrospray was established for the determination of ricinine in cooking oils. The homogenized samples, spiked with (13)C6-labelled ricinine as an internal standard, were extracted using ethanol/water (20:80, v/v) and purified by dispersive solid-phase extraction (dSPE) using primary-secondary amine (PSA) and C18 as adsorbents. The extract was separated in a short C18 reversed-phase column using methanol/water (25:75, v/v) as the mobile phase and detected in multiple reaction monitoring (MRM) mode with the absolute matrix effect of 93.2-102.2%. The alkali-metal adduct ions were discussed and the mass/mass fragmentation pathway was explained. Ricinine showed good linearity in the range of 0.5-50.0 μg/kg with the limit of quantitation 0.5 μg/kg. The recoveries were between 86.0% and 98.3% with the intra- and inter-day RSDs of 2.6-7.0%, 5.5-10.8%, respectively. This method could be applied to the rapid quantification of ricinine in cooking oils. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  8. Evaluation of bi-functionalized mesoporous silicas as reversed phase/cation-exchange mixed-mode sorbents for multi-residue solid phase extraction of veterinary drug residues in meat samples.

    PubMed

    Casado, Natalia; Pérez-Quintanilla, Damián; Morante-Zarcero, Sonia; Sierra, Isabel

    2017-04-01

    A SBA-15 type mesoporous silica was synthesized and bi-functionalized with octadecylsilane (C18) or octylsilane (C8), and sulfonic acid (SO 3 - ) groups in order to obtain materials with reversed-phase/strong cation-exchange mixed-mode retention mechanism. The resulting hybrid materials (SBA-15-C18-SO 3 - and SBA-15-C8-SO 3 - ) were comprehensively characterized. They showed high surface area, high pore volume and controlled porous size. Elemental analysis of the materials revealed differences in the amount of C18 and C8. SBA-15-C18-SO 3 - contained 0.19mmol/g of C18, while SBA-15-C8-SO 3 - presented 0.54mmol/g of C8. The SO 3 - groups anchored to the silica surface of the pore walls were 0.20 and 0.09mmol/g, respectively. The bi-functionalized materials were evaluated as SPE sorbents for the multi-residue extraction of 26 veterinary drug residues in meat samples using ultra-high-performance liquid chromatography coupled to mass spectrometry detector (UHPLC-MS/MS). Different sorbent amounts (100 and 200mg) and organic solvents were tested to optimize the extraction procedure. Both silicas showed big extraction potential and were successful in the extraction of the target analytes. The mixed-mode retention mechanism was confirmed by comparing both silicas with SBA-15 mesoporous silica mono-functionalized with C18 and C8. Best results were achieved with 200mg of SBA-15-C18-SO 3 - obtaining recoveries higher than 70% for the majority of analytes. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Graphene-encapsulated silica as matrix solid-phase dispersion extraction sorbents for the analysis of poly-methoxylated flavonoids in the leaves of Murraya panaculata (L.) Jack.

    PubMed

    Sun, Ting; Li, Xuwen; Yang, Jie; Li, Lanjie; Jin, Yongri; Shi, Xiaolei

    2015-06-01

    In this study, graphene-encapsulated silica was synthesized by a hydrothermal reduction strategy. The presence of silica in graphene was identified by Fourier-transform infrared spectrometry, X-ray diffraction and scanning electron microscopy. The graphene-encapsulated silica subsequently was used as adsorbent for matrix solid-phase dispersion extraction of poly-methoxylated flavonoids from the dried leaves of Murraya panaculata (L.) Jack. Compared with the other adsorbents (graphene, silica gel, C18 silica, neutral alumina, diatomaceous earth) and without any adsorbents, better results were obtained. Then a method for analysis of poly-methoxylated flavonoids was established by coupling matrix solid-phase dispersion extraction with ultra high performance liquid chromatography and UV detection. Compared with reflux extraction and ultrasonic extraction, the proposed method is quicker, more efficient and more environmental protection. Less than 10 min is needed from extraction to detection. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Antifouling booster biocide extraction from marine sediments: a fast and simple method based on vortex-assisted matrix solid-phase extraction.

    PubMed

    Caldas, Sergiane Souza; Soares, Bruno Meira; Abreu, Fiamma; Castro, Ítalo Braga; Fillmann, Gilberto; Primel, Ednei Gilberto

    2018-03-01

    This paper reports the development of an analytical method employing vortex-assisted matrix solid-phase dispersion (MSPD) for the extraction of diuron, Irgarol 1051, TCMTB (2-thiocyanomethylthiobenzothiazole), DCOIT (4,5-dichloro-2-n-octyl-3-(2H)-isothiazolin-3-one), and dichlofluanid from sediment samples. Separation and determination were performed by liquid chromatography tandem-mass spectrometry. Important MSPD parameters, such as sample mass, mass of C18, and type and volume of extraction solvent, were investigated by response surface methodology. Quantitative recoveries were obtained with 2.0 g of sediment sample, 0.25 g of C18 as the solid support, and 10 mL of methanol as the extraction solvent. The MSPD method was suitable for the extraction and determination of antifouling biocides in sediment samples, with recoveries between 61 and 103% and a relative standard deviation lower than 19%. Limits of quantification between 0.5 and 5 ng g -1 were obtained. Vortex-assisted MPSD was shown to be fast and easy to use, with the advantages of low cost and reduced solvent consumption compared to the commonly employed techniques for the extraction of booster biocides from sediment samples. Finally, the developed method was applied to real samples. Results revealed that the developed extraction method is effective and simple, thus allowing the determination of biocides in sediment samples.

  11. Determination of the cyanobacterial toxin cylindrospermopsin in algal food supplements.

    PubMed

    Liu, H; Scott, P M

    2011-06-01

    For the analysis of blue-green algal food supplements for cylindrospermopsin (CYN), a C18 solid-phase extraction column and a polygraphitized carbon solid-phase extraction column in series was an effective procedure for the clean-up of extracts. Determination of CYN was by liquid chromatography with ultraviolet light detection. At extract spiking levels of CYN equivalent to 25-500 µg g(-1), blue-green algal supplement recoveries were in the range 70-90%. CYN was not detected in ten samples of food supplements and one chocolate product, all containing blue-green algae. The limit of detection for the method was 16 µg g(-1), and the limit of quantification was 52 µg g(-1).

  12. Molecularly imprinted polymer/cryogel composites for solid-phase extraction of bisphenol A from river water and wine.

    PubMed

    Baggiani, Claudio; Baravalle, Patrizia; Giovannoli, Cristina; Anfossi, Laura; Giraudi, Gianfranco

    2010-05-01

    Superporous monolithic hydrogels (cryogel monoliths) are elastic, sponge-like materials that can be prepared in an aqueous medium through a cryotropic gelation technique. These monoliths show interesting properties for the development of high-throughput solid-phase extraction supports to treat large volumes of aqueous samples. In this work, a cryogel-supported molecularly imprinted solid-phase extraction approach for the endocrine disruptor bisphenol A (BPA) from river water and wine samples is presented. An imprinted polymer with molecular recognition properties for BPA was prepared in acetonitrile by thermal polymerization of a mixture of 4,4'-dihydroxy-2,2-diphenyl-1,1,1,3,3,3-trifluoropropane as a mimic template of BPA, 4-vinylpyridine and trimethylolpropane trimethacrylate in a molar ratio of 1 + 6 + 6. Fine imprinted particles (<10 microm) were embedded in a poly-acrylamide-co-N,N'-methylenbisacrylamide cryogel obtained by ammonium persulfate-induced cryopolymerization at -18 degrees C. The resulting monolithic gel was evaluated for its use as a sorbent support in an off-line solid-phase extraction approach to recover BPA from dilute aqueous samples with minimum pre-loading work-up. The optimized extraction protocol resulted in a reliable MISPE method suitable to selectively extract and preconcentrate BPA from river water and red wine samples, demonstrating the practical feasibility of cryogel-trapped imprinted polymers as solid-phase extraction materials.

  13. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of pesticides in water by C-18 solid-phase extraction and capillary-column gas chromatography/mass spectrometry with selected-ion monitoring

    USGS Publications Warehouse

    Zaugg, Steven D.; Sandstrom, Mark W.; Smith, Steven G.; Fehlberg, Kevin M.

    1995-01-01

    A method for the isolation of 41 pesticides and pesticide metabolites in natural-water samples using C-18 solid-phase extraction and determination by capillary-column gas chromatography/mass spectrometry with selected-ion monitoring is described. Water samples are filtered to remove suspended particulate matter and then are pumped through disposable solid-phase extraction columns containing octadecyl-bonded porous silica to extract the pesticides. The columns are dried using carbon dioxide or nitrogen gas, and adsorbed pesticides are removed from the columns by elution with 3.0 milliliters of hexane-isopropanol (3:1). Extracted pesticides are determined by capillary- column gas chromatography/mass spectrometry with selected-ion monitoring of three characteristic ions. The upper concentration limit is 4 micrograms per liter (g/L) for most pesticides, with the exception of widely used corn herbicides--atrazine, alachlor, cyanazine, and metolachlor--which have upper concentration limits of 20 g/L. Single- operator method detection limits in reagent-water samples range from 0.001 to 0.018 g/L. Average short-term single-operator precision in reagent- water samples is 7 percent at the 0.1- and 1.0-g/L levels and 8 percent at the 0.01-g/L level. Mean recoveries in reagent-water samples are 73 percent at the 0.1- and 1.0-g/L levels and 83 percent at the 0.01-g/L level. The estimated holding time for pesticides after extraction on the solid-phase extraction columns was 7 days. An optional on-site extraction procedure allows for samples to be collected and processed at remote sites where it is difficult to ship samples to the laboratory within the recommended pre-extraction holding time.

  14. [Rapid identification of micro-constituents in monoammonium glycyrrhizinate raw materials by high-pressure solid phase extraction-high performance liquid chromatography-mass spectrometry].

    PubMed

    Yang, Xue-Dong; Tang, Xu-Yan; Sang, Lin

    2012-11-01

    To establish a method for rapid identification of micro-constituents in monoammonium glycyrrhizinate by high-pressure solid phase extraction-high performance liquid chromatography-mass spectrometry. HPLC preparative chromatograph was adopted for determining the optimal method for high-pressure solid phase extraction under optimal conditions. 5C18-MS-II column (20.0 mm x 20.0 mm) was used as the extraction column, with 35% acetonitrile-acetic acid solution (pH 2. 20) as eluent at the speed of 16 mL x min(-1). The sample size was 0.5 mL, and the extraction cycle was 4.5 min. Then, extract liquid was analyzed by high performance liquid chromatography-mass spectrometry (HPLC-MS) after being concentrated by 100 times. Under the optimal condition of high-pressure solid phase extraction-high performance liquid chromatography-mass spectrometry, 10 components were rapidly identified from monoammonium glycyrrhizinate raw materials. Among them, the chemical structures of six micro-constituents were identified as 3-O-[beta-D-glucuronopyranosyl-beta-D-glucuronopyranosyl]-30-0-beta-D-apiopyranosylglycyrrhetic/3-O- [P-D-glucuronopyranosyl-beta-D-glucuronopyranosyl]-30-O-beta-D-arabinopyranosylglycyrrhetic, glycyrrhizic saponin F3, 22-hydroxyglycyrrhizin/18alpha-glycyrrhizic saponin G2, 3-O-[beta-D-rhamnopyranosyl]-24-hydroxyglycyrrhizin, glycyrrhizic saponin J2, and glycyrrhizic saponin B2 by MS(n) spectra analysis and reference to literatures. Four main chemical components were identified as glycyrrhizic saponin G2, 18beta-glycyrrhizic acid, uralglycyrrhizic saponin B and 18alpha-glycyrrhizic acid by liquid chromatography, MS(n) and ultraviolet spectra information and comparison with reference substances. The method can be used to identify chemical constituents in monoammonium glycyrrhizinate quickly and effectively, without any reference substance, which provides basis for quality control and safe application of monoammonium glycyrrhizinate-related products.

  15. Removal of sudan dyes from water with C18-functional ultrafine magnetic silica nanoparticles.

    PubMed

    Jiang, Chunzhu; Sun, Ying; Yu, Xi; Zhang, Lei; Sun, Xiumin; Gao, Yan; Zhang, Hanqi; Song, Daqian

    2012-01-30

    In this study, the new C(18)-functionalized ultrafine magnetic silica nanoparticles (C(18)-UMS NPs) were successfully synthesized and applied for extraction of sudan dyes in water samples based on the magnetic solid-phase extraction (MSPE). The extraction and concentration were carried out in one step by blending C(18)-UMS NPs and water samples. The sudan dyes adsorbed C(18)-UMS NPs were isolated from the matrix easily with an external magnetic field. After desorption the quantitation of sudan dyes was done by ultra fast liquid chromatography (UFLC). Satisfactory extraction recovery can be obtained with only 50 mg C(18)-UMS NPs. The effects of experimental parameters, including the amount of the nanoparticles, extraction time, pH value, desorption solvent, volume of desorption solvent and desorption time were investigated. The limits of detection for sudan I, II, III and IV were 0.066, 0.070, 0.12 and 0.12 ng mL(-1), respectively. Recoveries obtained by analyzing the six spiked water samples were between 68% and 103%. Copyright © 2011 Elsevier B.V. All rights reserved.

  16. Ionic Liquid-Bonded Fused Silica as a New Solid-Phase Microextraction Fiber for the Liquid Chromatographic Determination of Bisphenol A as an Endocrine Disruptor.

    PubMed

    Mohammadnezhad, Nasim; Matin, Amir Abbas; Samadi, Naser; Shomali, Ashkan; Valizadeh, Hassan

    2017-01-01

    Linear ionic liquid bonded to fused silica and its application as a solid-phase microextraction fiber for the extraction of bisphenol A (BPA) from water samples were studied. After optimization of microextraction conditions (15 mL sample volume, extraction time of 40 min, extraction temperature of 30 ± 1°C, 300 μL acetonitrile as the desorption solvent, and desorption time of 7 min), the fiber was used to extract BPA from packed mineral water, followed by HPLC-UV on an XDB-C18 column (150 × 4.6 mm id, 3.5 μm particle) with a mobile phase of acetonitrile-water (45 + 55%, v/v) and flow rate of 1 mL . min-1). A low LOD (0.20 μg . L-1) and good linearity (0.9977) in the calibration graph indicated that the proposed method was suitable for the determination of BPA.

  17. Determination of nonylphenol and nonylphenol ethoxylates in environmental solid samples by ultrasonic-assisted extraction and high performance liquid chromatography-fluorescence detection.

    PubMed

    Núñez, L; Turiel, E; Tadeo, J L

    2007-04-06

    A simple and rapid analytical method for the determination of nonylphenol (NP) and nonylphenol ethoxylates (NPEOx) in solid environmental samples has been developed. This method combines an ultrasonic-assisted extraction procedure in small columns and an enrichment step onto C(18) solid-phase extraction cartridges prior to separation using HPLC with fluorescence detection. Method optimization was carried out using soil samples fortified at different concentration levels (from 0.1 to 100 microg/g). Under optimum conditions, 2g of soil was placed in small glass columns and extraction was performed assisted by sonication (SAESC) at 45 degrees C in two consecutive steps of 15 min using a mixture of H(2)O/MeOH (30/70). The obtained extracts were collected, loaded onto 500 mg C(18) cartridges, and analytes were eluted with 3 x 1 ml of methanol and 1 ml of acetonitrile. Finally, sample extracts were evaporated under a nitrogen stream, redissolved in 500 microl H(2)O/AcN (50/50), and passed though a 0.45 microm nylon filter before final determination by HPLC-FL. The developed procedure allowed to achieve quantitative recoveries for NP and NPEOx, and was properly validated. Finally, the method was applied to the determination of these compounds in soils and other environmental solid samples such as sediments, compost and sludge.

  18. [Simultaneous determination of 9 ultraviolet stabilizers in food plastic packaging materials by solid phase extraction-high performance liquid chromatography].

    PubMed

    Zhang, Juzhou; Li, Jing; Shao, Dongliang; Yao, Bangben; Jiang, Junshu

    2012-02-01

    An effective high performance liquid chromatographic (HPLC) method has been developed for the simultaneous determination of 9 ultraviolet stabilizers in food plastic packaging materials. The food packaging samples were firstly extracted by methanol-ethyl acetate, and then purified by a C18 solid-phase extraction (SPE) column. The target compounds were separated on a ZORBAX SB-C18 column (250 mm x 4.6 mm, 5 microm) in gradient elution mode using methanol and water as mobile phases. The detection wavelength was at 310 nm. The linear plots of the nine ultraviolet stabilizers were obtained between 0.2 and 10 mg/L, with the correlation coefficients of above 0. 999 for the nine ultraviolet stabilizers. The limits of detection for this method were in the range from 0.05 to 0.1 mg/L. The recoveries spiked in commercial food plastic packaging materials were in the range of 70.2% - 89.0% with the relative standard deviations of 0.4% - 4.5%. The results indicated that the method is simple, accurate, and suitable for the simultaneous determination of the nine ultraviolet stabilizers in food plastic packaging materials.

  19. In situ continuous derivatization/pre-concentration of carbonyl compounds with 2,4-dinitrophenylhydrazine in aqueous samples by solid-phase extraction Application to liquid chromatography determination of aldehydes.

    PubMed

    Baños, Clara-Eugenia; Silva, Manuel

    2009-03-15

    A rapid and straightforward continuous solid-phase extraction system has been developed for in situ derivatization and pre-concentration of carbonyl compounds in aqueous samples. Initially 2,4-dinitrophenylhydrazine, the derivatizing agent, was adsorbed on a C(18) mini-column and then 15-ml of sample were continuously aspirated into the flow system, where the derivatization and pre-concentration of the analytes (low-molecular mass aldehydes) were performed simultaneously. Following elution, 20 microl of the extract were injected into a LC-DAD system, in which hydrazones were successfully separated in 12 min on a RP-C(18) column using a linear gradient mobile phase of acetonitrile-water of 60-100% acetonitrile for 8 min, flowing at 0.5 ml/min. The whole analytical process can be accomplished within ca. 35 min. Under optimum conditions, limits of detection were obtained between 0.3 and 1.0 microg/l and RSDs (inter-day precision) from 1.2 to 4.6%. Finally, some applications on water samples are presented with recoveries ranged from 95.8 to 99.4%.

  20. Automated solid-phase extraction of herbicides from water for gas chromatographic-mass spectrometric analysis

    USGS Publications Warehouse

    Meyer, M.T.; Mills, M.S.; Thurman, E.M.

    1993-01-01

    An automated solid-phase extraction (SPE) method was developed for the pre-concentration of chloroacetanilide and triazine herbicides, and two triazine metabolites from 100-ml water samples. Breakthrough experiments for the C18 SPE cartridge show that the two triazine metabolites are not fully retained and that increasing flow-rate decreases their retention. Standard curve r2 values of 0.998-1.000 for each compound were consistently obtained and a quantitation level of 0.05 ??g/l was achieved for each compound tested. More than 10,000 surface and ground water samples have been analyzed by this method.

  1. Determination of free and deconjugated testosterone and epitestosterone in urine using SPME and LC-MS/MS.

    PubMed

    Zhan, Yanwei; Musteata, Florin M; Basset, Fabien A; Pawliszyn, Janusz

    2011-01-01

    A thin sheet of polydimethylsilosane membrane was used as an extraction phase for solid-phase microextraction. Compared with fiber or rod solid-phase microextraction geometries, the thin film exhibited much higher extraction capacity without sacrificing extraction time due to its higher area-to-volume ratio. The analytical method involved direct extraction of unconjugated testosterone (T) and epitestosterone (ET) followed by separation on a C18 column and detection by selected reaction monitoring in positive ionization mode. The limit of detection was 1 ng/l for both T and ET. After method validation, free (unconjugated) T and ET were extracted and quantified in real samples. Since T and ET are extensively metabolized, the proposed method was also applied to extract the steroids after enzymatic deconjugation of urinary-excreted steroid glucuronides. The proposed method allows quantification of both conjugated and unconjugated steroids, and revealed that there was a change in the ratio of T to ET after enzymatic deconjugation, indicating different rates of metabolism.

  2. Preparative isolation of flavonoid glycosides from Sphaerophysa salsula using hydrophilic interaction solid-phase extraction coupled with two-dimensional preparative liquid chromatography.

    PubMed

    Jiao, Lijin; Tao, Yanduo; Wang, Weidong; Shao, Yun; Mei, Lijuan; Wang, Qilan; Dang, Jun

    2017-10-01

    An offline preparative two-dimensional reversed-phase liquid chromatography/hydrophilic interaction liquid chromatography coupled with hydrophilic interaction solid-phase extraction method was developed for the preparative isolation of flavonoid glycosides from a crude sample of Sphaerophysa salsula. First, the non-flavonoids were removed using an XAmide solid-phase extraction cartridge. Based on the separation results of three different chromatographic stationary phases, the first-dimensional preparation was performed on an XAqua C18 prep column, and 15 fractions were obtained from the 5.2 g target sample. Then, three representative fractions were selected for additional purification on an XAmide preparative column to further isolate the flavonoid glycosides. In all, eight flavonoid glycosides were isolated in purities over 97%. The results demonstrated that the two-dimensional liquid chromatography method used in this study was effective for the preparative separation of flavonoid glycosides from Sphaerophysa salsula. Additionally, this method showed great potential for the separation of flavonoid glycosides from other plant materials. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Selective trace enrichment of acidic pharmaceuticals in real water and sediment samples based on solid-phase extraction using multi-templates molecularly imprinted polymers.

    PubMed

    Duan, Yan-Ping; Dai, Chao-Meng; Zhang, Ya-Lei; Ling-Chen

    2013-01-03

    A novel multi-templates molecularly imprinted polymer (MIP), using acidic pharmaceuticals mixture (ibuprofen (IBP), naproxen (NPX), ketoprofen (KEP), diclofenac (DFC), and clofibric acid (CA)) as the template, was prepared as solid-phase extraction (SPE) material for the quantitative enrichment of acidic pharmaceuticals in environmental samples and off-line coupled with liquid chromatography-mass spectrometry (LC/MS/MS). Washing solvent was optimized in terms of kind and volume for removing the matrix constituents nonspecifically adsorbed on the MIP. When 1L of water sample spiked at 1μg/L was loaded onto the cartridge, the binding capacity of the MIP cartridge were 48.7μg/g for KEP, 60.7μg/g for NPX, 52μg/g for CA, 61.3μg/g for DFC and 60.7μg/g for IBP, respectively, which are higher than those of the commercial single template MIP in organic medium (e.g. toluene) reported in the literature. Recoveries of the five acidic pharmaceuticals extracted from 1L of real water samples such as lake water and wastewater spiked at 1μg/L were more than 95%. The recoveries of acidic pharmaceuticals extracted from 10-g sediment sample spiked at the 10ng/g level were in the range of 77.4-90.6%. To demonstrate the potential of the MIP obtained, a comparison with commercial C18 SPE cartridge was performed. Molecularly imprinted solid-phase extraction (MISPE) cartridge showed higher recoveries than commercial C18 SPE cartridge for acidic pharmaceuticals. These results showed the suitability of the MISPE method for the selective extraction of a group of structurally related compounds such as acidic pharmaceuticals. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Characterization of rhamnolipids by liquid chromatography/mass spectrometry after solid-phase extraction.

    PubMed

    Behrens, Beate; Engelen, Jeannine; Tiso, Till; Blank, Lars Mathias; Hayen, Heiko

    2016-04-01

    Rhamnolipids are surface-active agents with a broad application potential that are produced in complex mixtures by bacteria of the genus Pseudomonas. Analysis from fermentation broth is often characterized by laborious sample preparation and requires hyphenated analytical techniques like liquid chromatography coupled to mass spectrometry (LC-MS) to obtain detailed information about sample composition. In this study, an analytical procedure based on chromatographic method development and characterization of rhamnolipid sample material by LC-MS as well as a comparison of two sample preparation methods, i.e., liquid-liquid extraction and solid-phase extraction, is presented. Efficient separation was achieved under reversed-phase conditions using a mixed propylphenyl and octadecylsilyl-modified silica gel stationary phase. LC-MS/MS analysis of a supernatant from Pseudomonas putida strain KT2440 pVLT33_rhlABC grown on glucose as sole carbon source and purified by solid-phase extraction revealed a total of 20 congeners of di-rhamnolipids, mono-rhamnolipids, and their biosynthetic precursors 3-(3-hydroxyalkanoyloxy)alkanoic acids (HAAs) with different carbon chain lengths from C8 to C14, including three rhamnolipids with uncommon C9 and C11 fatty acid residues. LC-MS and the orcinol assay were used to evaluate the developed solid-phase extraction method in comparison with the established liquid-liquid extraction. Solid-phase extraction exhibited higher yields and reproducibility as well as lower experimental effort.

  5. Determination of Low Concentrations of Acetochlor in Water by Automated Solid-Phase Extraction and Gas Chromatography with Mass-Selective Detection

    USGS Publications Warehouse

    Lindley, C.E.; Stewart, J.T.; Sandstrom, M.W.

    1996-01-01

    A sensitive and reliable gas chromatographic/mass spectrometric (GC/MS) method for determining acetochlor in environmental water samples was developed. The method involves automated extraction of the herbicide from a filtered 1 L water sample through a C18 solid-phase extraction column, elution from the column with hexane-isopropyl alcohol (3 + 1), and concentration of the extract with nitrogen gas. The herbicide is quantitated by capillary/column GC/MS with selected-ion monitoring of 3 characteristic ions. The single-operator method detection limit for reagent water samples is 0.0015 ??g/L. Mean recoveries ranged from about 92 to 115% for 3 water matrixes fortified at 0.05 and 0.5 ??g/L. Average single-operator precision, over the course of 1 week, was better than 5%.

  6. Are extracted materials truly representative of original samples? Impact of C18 extraction on CDOM optical and chemical properties

    NASA Astrophysics Data System (ADS)

    Andrew, Andrea; Del Vecchio, Rossana; Zhang, Yi; Subramaniam, Ajit; Blough, Neil

    2016-02-01

    Some properties of dissolved organic matter (DOM) and chromophoric dissolved organic matter (CDOM) can be easily measured directly on whole waters, while others require sample concentration and removal of natural salts. To increase CDOM content and eliminate salts, solid phase extraction is often employed. Biases following extraction and elution are inevitable, thus raising the question of how truly representative the extracted material is of the original. In this context, we investigated the wavelength dependence of extraction efficiency for C18 cartridges with respect to CDOM optical properties using samples obtained from the Middle Atlantic Bight (MAB) and the Equatorial Atlantic Ocean (EAO). Further, we compared the optical changes of C18 extracts and the corresponding whole water following chemical reduction with sodium borohydride (NaBH4). C18 cartridges preferentially extracted long-wavelength absorbing/emitting material for samples impacted by riverine input. Extraction efficiency overall decreased with offshore distance away from riverine input. Spectral slopes of C18-OM samples were also almost always lower than those of their corresponding CDOM samples supporting the preferential extraction of higher molecular weight absorbing material. The wavelength dependence of the optical properties (absorption, fluorescence emission and quantum yield) of the original water samples and their corresponding extracted material were very similar. C18 extracts and corresponding water samples further exhibited comparable optical changes following NaBH4 reduction, thus suggesting a similarity in nature (structure) of the optically active extracted material, independent of geographical locale. Altogether, these data suggested a strong similarity between C18 extracts and corresponding whole waters, thus indicating that extracts are representative of the CDOM content of original waters.

  7. Are Extracted Materials Truly Representative of Original Samples? Impact of C18 Extraction on CDOM Optical and Chemical Properties

    PubMed Central

    Andrew, Andrea A.; Del Vecchio, Rossana; Zhang, Yi; Subramaniam, Ajit; Blough, Neil V.

    2016-01-01

    Some properties of dissolved organic matter (DOM) and chromophoric dissolved organic matter (CDOM) can be easily measured directly on whole waters, while others require sample concentration and removal of natural salts. To increase CDOM content and eliminate salts, solid phase extraction (SPE) is often employed. Biases following extraction and elution are inevitable, thus raising the question of how truly representative the extracted material is of the original. In this context, we investigated the wavelength dependence of extraction efficiency for C18 cartridges with respect to CDOM optical properties using samples obtained from the Middle Atlantic Bight (MAB) and the Equatorial Atlantic Ocean (EAO). Further, we compared the optical changes of C18 extracts and the corresponding whole water following chemical reduction with sodium borohydride (NaBH4). C18 cartridges preferentially extracted long-wavelength absorbing/emitting material for samples impacted by riverine input. Extraction efficiency overall decreased with offshore distance away from riverine input. Spectral slopes of C18-OM samples were also almost always lower than those of their corresponding CDOM samples supporting the preferential extraction of higher molecular weight absorbing material. The wavelength dependence of the optical properties (absorption, fluorescence emission, and quantum yield) of the original water samples and their corresponding extracted material were very similar. C18 extracts and corresponding water samples further exhibited comparable optical changes following NaBH4 reduction, thus suggesting a similarity in nature (structure) of the optically active extracted material, independent of geographical locale. Altogether, these data suggested a strong similarity between C18 extracts and corresponding whole waters, thus indicating that extracts are representative of the CDOM content of original waters. PMID:26904536

  8. Are Extracted Materials Truly Representative of Original Samples? Impact of C18 Extraction on CDOM Optical and Chemical Properties.

    PubMed

    Andrew, Andrea A; Del Vecchio, Rossana; Zhang, Yi; Subramaniam, Ajit; Blough, Neil V

    2016-01-01

    Some properties of dissolved organic matter (DOM) and chromophoric dissolved organic matter (CDOM) can be easily measured directly on whole waters, while others require sample concentration and removal of natural salts. To increase CDOM content and eliminate salts, solid phase extraction (SPE) is often employed. Biases following extraction and elution are inevitable, thus raising the question of how truly representative the extracted material is of the original. In this context, we investigated the wavelength dependence of extraction efficiency for C18 cartridges with respect to CDOM optical properties using samples obtained from the Middle Atlantic Bight (MAB) and the Equatorial Atlantic Ocean (EAO). Further, we compared the optical changes of C18 extracts and the corresponding whole water following chemical reduction with sodium borohydride (NaBH4). C18 cartridges preferentially extracted long-wavelength absorbing/emitting material for samples impacted by riverine input. Extraction efficiency overall decreased with offshore distance away from riverine input. Spectral slopes of C18-OM samples were also almost always lower than those of their corresponding CDOM samples supporting the preferential extraction of higher molecular weight absorbing material. The wavelength dependence of the optical properties (absorption, fluorescence emission, and quantum yield) of the original water samples and their corresponding extracted material were very similar. C18 extracts and corresponding water samples further exhibited comparable optical changes following NaBH4 reduction, thus suggesting a similarity in nature (structure) of the optically active extracted material, independent of geographical locale. Altogether, these data suggested a strong similarity between C18 extracts and corresponding whole waters, thus indicating that extracts are representative of the CDOM content of original waters.

  9. Bound Volatile Precursors in Genotypes in the Pedigree of 'Marion' Blackberry (Rubus Sp.)

    USDA-ARS?s Scientific Manuscript database

    Glycosidically bound volatiles and precursors in genotypes representing the pedigree for 'Marion' blackberry were investigated over two growing seasons. The volatile precursors were isolated using a C18 solid-phase extraction column. After enzymatic hydrolysis, the released volatiles were analyzed u...

  10. Validated high-performance liquid chromatographic method utilizing solid-phase extraction for the simultaneous determination of naringenin and hesperetin in human plasma.

    PubMed

    Kanaze, Feras Imad; Kokkalou, Eugene; Georgarakis, Manolis; Niopas, Ioannis

    2004-03-05

    Naringenin and hesperetin, the aglycones of the flavanone glucosides naringin and hesperidin occur naturally in citrus fruits. They exert a variety of pharmacological effects such as antioxidant, blood lipid-lowering, anticarcinogenic and inhibit selected cytochrome P-450 enzymes resulting in drug interactions. A specific, sensitive, precise, and accurate solid-phase extraction high-performance liquid chromatographic (HPLC) assay for the simultaneous determination of naringenin and hesperetin in human plasma was developed and validated. After addition of 7-ethoxycoumarin as internal standard, plasma samples were incubated with beta-glucuronidase/sulphatase, and the analytes were isolated from plasma by solid-phase extraction using C(18) cartridges and separated on a C(8) reversed phase column with methanol/water/acetic acid (40:58:2, v/v/v) as the eluent at 45 degrees C. The method was linear in the 10-300 ng/ml concentration range for both naringenin and hesperetin (r>0.999). Recovery for naringenin, hesperetin and internal standard was greater than 76.7%. Intra- and inter-day precision for naringenin ranged from 1.4 to 4.2% and from 1.9 to 5.2%, respectively, and for hesperetin ranged from 1.3 to 4.1% and from 1.7 to 5.1%, respectively. Accuracy was better than 91.5 and 91.3% for naringenin and hesperetin, respectively.

  11. [Determination of alkylphenol and alkylphenolpolyethoxylates in brine by solid phase extraction and high performance liquid chromatography-mass spectrometry].

    PubMed

    Wang, Jincheng; Xiong, Li; Zhang, Haijun; Chen, Jiping

    2011-12-01

    A simple method based on solid phase extraction (SPE) coupled with high performance liquid chromatography-mass spectrometry (HPLC-MS) was developed for the determination of octylphenol (OP), nonylphenol (NP), octylphenol ethoxylates (OPEOs) and nonylphenol ethoxylates (NPEOs) in brine. The extraction and cleanup of brine samples were performed on C18 solid-phase extraction cartridges. The complete separation among OP, NP, OPEOs and NPEOs was achieved on a Hypersil GOLD analytical column with methanol-water as the mobile phase. The determination was achieved using HPLC-MS with electrospray ionization (ESI) in selected ion monitoring mode. The results showed that the average recoveries of target compounds were 59.6% - 104.4% and the corresponding relative standard deviations (RSDs, n = 3) were 1.0% - 13.5%. The instrumental limits of detection for the compounds were 0.08 - 3 microg/L. This method was applied to the analysis of the samples of seawater near Dalian coast. The results showed that both NP and NPEOs were detected in all samples and their concentrations in seaport and oil port were much higher than those in other sampling sites.

  12. Utility of solid phase extraction for spectrophotometric determination of gold in water, jewel and ore samples.

    PubMed

    Amin, Alaa S

    2010-12-01

    A highly sensitive, selective and rapid method for the determination μg L(-1) level of Au(III) based on the rapid reaction of Au(III) with 2,3-dichloro-6-(3-carboxy-2-hydroxy-1-naphthylazo)quinoxaline (DCHNAQ) and the solid phase extraction of the colored complex with a reversed phase polymer-based C18 cartridge have been developed. The DCHNAQ reacted with Au(III) to form a violet complex of a molar ratio 3:1 [DCHNAQ to Au(III)] in the presence of 5.0 M of phosphoric acid solution and Triton X-100 medium. This complex was enriched by the solid phase extraction with a polymer-based C18 cartridge. The enrichment factor of 100 was achieved. The molar absorptivity of the complex is 2.73×10(5) l mol(-1) cm(-1) at 633 nm in the measured solution. The system obeys Beer's law in the range of 0.02-1.30 μg ml(-1), whereas the optimum concentration ranges obtained from Ringbom plot was 0.08-1.24 μg ml(-1). The relative standard deviation for ten replicates sample of 0.6 μg ml(-1) level is 1.28%. The detection and quantification limits, are 6.1 and 19.5 ng ml(-1) in the original sample. This method was applied to the determination of gold in water, jewel and ore samples with good results comparing to the GFAAS method. Copyright © 2010 Elsevier B.V. All rights reserved.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Feng; Cooper, S.F.

    A novel gas chromatography-mass spectrometric (GC-MS) method was developed to confirm and identify metoprolol and its metabolites by double derivatization with S-(-)menthyl chloroformate [(-)-MCF] and N-methyl(trimethylsilyl-trifluoroacetamide) (MSTFA). This is the first report, which describes the simultaneous identification of metoprolol, its one major acidc and other basic metabolites in human urine based on solid-phase extraction with C{sub 18} reversed-phase cartridges. 12 refs., 4 figs.

  14. Molecularly imprinted solid-phase extraction for determination of tilmicosin in feed using high performance liquid chromatography.

    PubMed

    Zheng, Yaqiu; Liu, Yahong; Guo, Hongbin; He, Limin; Fang, Binghu; Zeng, Zhenling

    2011-04-01

    A simple, sensitive and reproducible molecularly imprinted solid-phase extraction (MISPE) coupled with high performance liquid chromatographic method was developed for monitoring tilmicosin in feeds. The polymers were prepared using tylosin as mimic template molecule, methacrylic acid as functional monomer and ethylene glycol dimethacrylate as cross-linking monomer, and chloroform as a solvent by bulk polymerization. Under the optimum MISPE conditions, the novel polymer sorbent can selectively extract and enrich tilmicosin from variety of feeds. The MISPE cartridge was better than non-imprinted, C(18) and HLB cartridges in terms of both recovery and precision. Mean recoveries of tilmicosin from five kinds of feeds spiked at 1, 10 and 50 mg kg(-1) ranged from 76.9% to 95.6%, with intra-day and inter-day relative standard deviation less than 7.6%. The linearity was ranged from 1.0 to 100 mg L(-1) for matrix standard solution (r=0.9990). The limit of detection was approximately 0.35 mg kg(-1) and the limit of quantification was approximately 0.98 mg kg(-1). There was cleaner chromatogram by using MISPE than C(18) and HLB SPE. Copyright © 2011 Elsevier B.V. All rights reserved.

  15. Automated solid-phase extraction and liquid chromatography for assay of cyclosporine in whole blood.

    PubMed

    Kabra, P M; Wall, J H; Dimson, P

    1987-12-01

    In this rapid, precise, accurate, cost-effective, automated liquid-chromatographic procedure for determining cyclosporine in whole blood, the cyclosporine is extracted from 0.5 mL of whole blood together with 300 micrograms of cyclosporin D per liter, added as internal standard, by using an Advanced Automated Sample Processing unit. The on-line solid-phase extraction is performed on an octasilane sorbent cartridge, which is interfaced with a RP-8 guard column and an octyl analytical column, packed with 5-microns packing material. Both columns are eluted with a mobile phase containing acetonitrile/methanol/water (53/20/27 by vol) at a flow rate of 1.5 mL/min and column temperature of 70 degrees C. Absolute recovery of cyclosporine exceeded 85% and the standard curve was linear to 5000 micrograms/L. Within-run and day-to-day CVs were less than 8%. Correlation between automated and manual Bond-Elut extraction methods was excellent (r = 0.987). None of 18 drugs and four steroids tested interfered.

  16. Rapid and sensitive determination of major polyphenolic components in Euphoria longana Lam. seeds using matrix solid-phase dispersion extraction and UHPLC with hybrid linear ion trap triple quadrupole mass spectrometry.

    PubMed

    Rathore, Atul S; Sathiyanarayanan, L; Deshpande, Shreekant; Mahadik, Kakasaheb R

    2016-11-01

    A rapid and sensitive method for the extraction and determination of four major polyphenolic components in Euphoria longana Lam. seeds is presented for the first time based on matrix solid-phase dispersion extraction followed by ultra high performance liquid chromatography with hybrid triple quadrupole linear ion trap mass spectrometry. Matrix solid-phase dispersion method was designed for the extraction of Euphoria longana seed constituents and compared with microwave-assisted extraction and ultrasonic-assisted extraction methods. An Ultra high performance liquid chromatography with hybrid triple quadrupole linear ion-trap mass spectrometry method was developed for quantitative analysis in multiple-reaction monitoring mode in negative electrospray ionization. The chromatographic separation was accomplished using an ACQUITY UPLC BEH C 18 (2.1 mm × 50 mm, 1.7 μm) column with gradient elution of 0.1% aqueous formic acid and 0.1% formic acid in acetonitrile. The developed method was validated with acceptable linearity (r 2 > 0.999), precision (RSD ≤ 2.22%) and recovery (RSD ≤ 2.35%). The results indicated that matrix solid-phase dispersion produced comparable extraction efficiency compared with other methods nevertheless was more convenient and time-saving with reduced requirements on sample and solvent volumes. The proposed method is rapid and sensitive in providing a promising alternative for extraction and comprehensive determination of active components for quality control of Euphoria longana products. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Characterisation of chamomile volatiles by simultaneous distillation solid-phase extraction in comparison to hydrodistillation and simultaneous distillation extraction.

    PubMed

    Krüger, Hans

    2010-05-01

    A new method for complete separation of steam-volatile organic compounds is described using the example of chamomile flowers. This method is based on the direct combination of hydrodistillation and solid-phase extraction in a circulation apparatus. In contrast to hydrodistillation and simultaneous distillation extraction (SDE), an RP-18 solid phase as adsorptive material is used rather than a water-insoluble solvent. Therefore, a prompt and complete fixation of all volatiles takes place, and the circulation of water-soluble bisabololoxides as well as water-soluble and thermolabile en-yne-spiroethers is inhibited. This so-called simultaneous distillation solid-phase extraction (SD-SPE) provides extracts that better characterise the real composition of the vapour phase, as well as the composition of inhalation vapours, than do SDE extracts or essential oils obtained by hydrodistillation. The data indicate that during inhalation therapy with chamomile, the bisabololoxides and spiroethers are more strongly involved in the inhaling activity than so far assumed. Georg Thieme Verlag KG Stuttgart New York.

  18. High-performance liquid chromatographic determination of ursodeoxycholic acid after solid phase extraction of blood serum and detection-oriented derivatization.

    PubMed

    Nobilis, M; Pour, M; Kunes, J; Kopecký, J; Kvĕtina, J; Svoboda, Z; Sládková, K; Vortel, J

    2001-03-01

    Ursodeoxycholic acid (3 alpha,7 beta-dihydroxy-5 beta-cholanoic acid, UDCA) is a therapeutically applicable bile acid widely used for the dissolution of cholesterol-rich gallstones and in the treatment of chronic liver diseases associated with cholestasis. UDCA is more hydrophilic and less toxic than another therapeutically valuable bile acid, chenodeoxycholic acid (CDCA), the 7 alpha-epimer of UDCA. Procedures for sample preparation and HPLC determination of UDCA in blood serum were developed and validated. A higher homologue of UDCA containing an additional methylene group in the side chain was synthetized and used as an internal standard (IS). Serum samples with IS were diluted with a buffer (pH=7). The bile acids and IS were captured using solid phase extraction (C18 cartridges). The carboxylic group of the analytes was derivatized using 2-bromo-2'-acetonaphthone (a detection-oriented derivatization), and reaction mixtures were analyzed (HPLC with UV 245 nm detection; a 125--4 mm column containing Lichrospher 100 C18, 5 microm; mobile phase: acetonitrile--water, 6:4 (v/v)). Following validation, this method was used for pharmacokinetic studies of UDCA in humans.

  19. A bleached-kraft mill effluent fraction causing induction of a fish mixed-function oxygenase enzyme

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burnison, B.K.; Hodson, P.V.; Nuttley, D.J.

    1996-09-01

    Pulp mill effluents contain a myriad of chemicals that have the potential to cause deleterious effects on aquatic biota in receiving waters. Some of these chemicals evoke an acute lethal response of exposed biota while others evoke sublethal responses. One such sublethal response is the induction of mixed-function oxygenases (MFO) in fish, specifically the CYP1A1 enzyme ethoxy-resorufin-o-deethylase (EROD). Compounds causing MFO induction include congeners of polychlorinated biphenyls (PCBs), dioxins, furans, and polycyclic aromatic hydrocarbons (PAHs). The authors followed the partitioning of the inducing chemicals in pulp mill effluent fractions by Toxicity Identification Evaluation (TIE), or bioassay-driven chemical analysis. This proceduremore » was eventually modified to a more direct technique involving centrifugation, filtration, cleanup procedures, and C{sub 18} solid-phase adsorption. The extracts from the fractionation of two pulp mill effluents after secondary treatment were tested for EROD-inducing activity in a 4-d rainbow trout bioassay. The methanol extracts of particulates/colloids showed significant inducing capacity in Mill A effluent but not in Mill B effluent. The C{sub 18} methanol extracts induced activity from both effluents, with extracts from Mill A causing the greatest response. The particulate/colloidal extract (Mill A) was used as the source material for chemicals which caused EROD induction. The fraction was purified by solid-phase extraction techniques and reverse-phase high-performance liquid chromatography. The majority of the EROD activity was found in the moderately nonpolar region of the chromatogram (K{sub ow} = 4.6 to 5.1).« less

  20. Quantitative determination of risperidone, paliperidone and olanzapine in human serum by liquid chromatography-tandem mass spectrometry coupled with on-line solid-phase extraction.

    PubMed

    Ruan, Can-Jun; Guo, Wei; Zhou, Miao; Guo, Gui-Xin; Wang, Chuan-Yue; Li, Wen-Biao; de Leon, Jose

    2018-07-01

    A recent guideline recommends therapeutic drug monitoring for risperidone, paliperidone and olanzapine, which are frequently used second-generation antipsychotics. We developed a simple high-performance liquid chromatography-tandem mass spectrometry coupled with an online solid-phase extraction method that can be used to measure risperidone, paliperidone and olanzapine using small (40 μL) samples. The analytes were extracted from serum samples automatically pre-concentrated and purified by C 8 (5 μm, 2.1 × 30 mm) solid-phase extraction cartridges, then chromatographed on an Xbidge™ C 18 column (3.5 μm, 100 × 2.1 mm) thermostatted at 30°C with a mobile phase consisting of 70% acetonitrile and 30% ammonium hydroxide 1% solution at an isocratic flow rate of 0.3 mL/min, and detected with tandem mass spectrometry. The assay was validated in the concentration range from 2.5 to 160 ng/mL. Intra- and inter-day precision for all analytes was between 1.1 and 8.2%; method accuracy was between 6.6 and 7.6%. The risperidone and paliperidone assay was compared with a high-performance liquid chromatography-ultraviolet assay currently used in our hospital for risperidone and paliperidone therapeutic drug monitoring, and the results of weighted Deming regression analysis showed good agreement. For the olanzapine assay, we compared 20 samples in separate re-assays on different days; all the relative errors were within the 20% recommended limit. Copyright © 2018 John Wiley & Sons, Ltd.

  1. [A Simultaneous Determination Method with Acetonitrile-n-Hexane Partitioning and Solid-Phase Extraction for Pesticide Residues in Livestock and Marine Products by GC-MS].

    PubMed

    Yoshizaki, Mayuko; Kobayashi, Yukari; Shimizu, Masanori; Maruyama, Kouichi

    2015-01-01

    A simultaneous determination method was examined for 312 pesticides (including isomers) in muscle of livestock and marine products by GC-MS. The pesticide residues extracted from samples with acetone and n-hexane were purified by acetonitrile-n-hexane partitioning, and C18 and SAX/PSA solid-phase extraction without using GPC. Matrix components such as cholesterol were effectively removed. In recovery tests performed by this method using pork, beef, chicken and shrimp, 237-257 pesticides showed recoveries within the range of 70-120% in each sample. Validity was confirmed for 214 of the target pesticides by means of a validation test using pork. In comparison with the Japanese official method using GPC, the treatment time of samples and the quantity of solvent were reduced substantially.

  2. [Preparation of a novel activated carbon coating fiber for solid phase micro-extraction and its application for halocarbon compound analysis in water].

    PubMed

    Wang, Shutao; Wang, Yan; You, Hong; Liang, Zhihua

    2004-09-01

    A novel activated carbon coating fiber used for solid phase micro-extraction (SPME) was prepared using activated carbon powder and silica resin adhesive. The extraction properties of the novel activated carbon coating fiber were investigated. The results indicate that this coating fiber has high concentration ability, with enrichment factors for chloroform, carbon tetrachloride, trichloroethylene and tetrachloroethylene in the range of 13.8 to 18.7. The fiber is stable at temperature as high as 290 degrees C and it can be used for over 140 times at 250 degrees C. The activated carbon coating fiber was then applied to the analysis of the four halocarbon compounds mentioned above. A linear correlation with correlation coefficients between 0.995 2 and 0.999 4 and the detection limits between 0.008 and 0.05 microg/L were observed. The method was also applied to a real water sample analysis and the recoveries of these halocarbon compounds were from 95.5% to 104.6%.

  3. Molecular imprinting solid phase extraction for selective detection of methidathion in olive oil.

    PubMed

    Bakas, Idriss; Oujji, Najwa Ben; Moczko, Ewa; Istamboulie, Georges; Piletsky, Sergey; Piletska, Elena; Ait-Ichou, Ihya; Ait-Addi, Elhabib; Noguer, Thierry; Rouillon, Régis

    2012-07-13

    A specific adsorbent for extraction of methidathion from olive oil was developed. The design of the molecularly imprinted polymer (MIP) was based on the results of the computational screening of the library of polymerisable functional monomers. MIP was prepared by thermal polymerisation using N,N'-methylene bisacrylamide (MBAA) as a functional monomer and ethylene glycol dimethacrylate (EGDMA) as a cross-linker. The polymers based on the itaconic acid (IA), methacrylic acid (MAA) and 2-(trifluoromethyl)acryl acid (TFMAA) functional monomers and one control polymer which was made without functional monomers with cross-linker EGDMA were also synthesised and tested. The performance of each polymer was compared using corresponding imprinting factor. As it was predicted by molecular modelling the best results were obtained for the MIP prepared with MBAA. The obtained MIP was optimised in solid-phase extraction coupled with high performance liquid chromatography (MISPE-HPLC-UV) and tested for the rapid screening of methidathion in olive oil. The proposed method allowed the efficient extraction of methidathion for concentrations ranging from 0.1 to 9 mg L(-1) (r(2)=0.996). The limits of detection (LOD) and quantification (LOQ) in olive oil were 0.02 mg L(-1) and 0.1 mg L(-1), respectively. MIPs extraction was much more effective than traditional C18 reverse-phase solid phase extraction. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Development and validation of an HPLC-method for determination of free and bound phenolic acids in cereals after solid-phase extraction.

    PubMed

    Irakli, Maria N; Samanidou, Victoria F; Biliaderis, Costas G; Papadoyannis, Ioannis N

    2012-10-01

    Whole cereal grains are a good source of phenolic acids associated with reduced risk of chronic diseases. This paper reports the development and validation of a high-performance liquid chromatography-diode array detection (HPLC-DAD) method for the determination of phenolic acids in cereals in either free or bound form. Extraction of free phenolic acids and clean-up was performed by an optimised solid-phase extraction (SPE) protocol on Oasis HLB cartridges using aqueous methanol as eluant. The mean recovery of analytes ranged between 84% and 106%. Bound phenolic acids were extracted using alkaline hydrolysis with mean recoveries of 80-95%, except for gallic acid, caffeic acid and protocatechuic acid. Both free and bound phenolic extracts were separated on a Nucleosil 100 C18 column, 5 μm (250 mm × 4.6 mm) thermostated at 30 °C, using a linear gradient elution system consisting of 1% (v/v) acetic acid in methanol. Method validation was performed by means of linearity, accuracy, intra-day and inter-day precision and sensitivity. Detection limits ranged between 0.13 and 0.18 μg/g. The method was applied to the analysis of free and bound phenolic acids contents in durum wheat, bread wheat, barley, oat, rice, rye, corn and triticale. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. Solid-phase extraction-gas chromatography and solid-phase extraction-gas chromatography-mass spectrometry determination of corrosion inhibiting long-chain primary alkyl amines in chemical treatment of boiler water in water-steam systems of power plants.

    PubMed

    Kusch, Peter; Knupp, Gerd; Hergarten, Marcus; Kozupa, Marian; Majchrzak, Maria

    2006-04-28

    Gas chromatography with simultaneous flame-ionization detection (FID) and a nitrogen-phosphorus detection (NPD) as well as gas chromatography-mass spectrometry (GC/MS) has been used to characterize long-chain primary alkyl amines after derivatization with trifluoroacetic anhydride (TFAA). Electron impact ionization- (EI) and negative chemical ionization (NCI) mass spectra of trifluoroacetylated derivatives of the identified tert-octadecylamines are presented for the first time. The corrosion inhibiting alkyl amines were applied in a water-steam circuit of energy systems in the power industry. Solid-phase extraction (SPE) with octadecyl bonded silica (C18) sorbents followed by gas chromatography were used for quantification of the investigated tert-octadecylamines in boiler water, superheated steam and condensate samples from the power plant. The estimated values were: 89 microg l(-1)(n = 5, RSD = 7.8%), 45 microg l(-1) (n = 5, RSD = 5.4%) and 37 microg l(-1)(n = 5, RSD = 2.3%), respectively.

  6. Determination of organophosphorus pesticides in bovine tissue by an on-line coupled matrix solid-phase dispersion-solid phase extraction-high performance liquid chromatography with diode array detection method.

    PubMed

    Gutiérrez Valencia, Tania M; García de Llasera, Martha P

    2011-09-28

    A miniaturized method based on matrix solid-phase dispersion coupled to solid phase extraction and high performance liquid chromatography with diode array detection (MSPD-SPE-HPLC/DAD) was developed for the trace simultaneous determination of the following organophosphorus pesticides (OPPs) in bovine tissue: parathion-methyl, fenitrothion, parathion, chlorfenvinphos, diazinon, ethion, fenchlorphos, chlorpyrifos and carbophenothion. To perform the coupling between MSPD and SPE, 0.05 g of sample was dispersed with 0.2 g of C(18) silica sorbent and packed into a stainless steel cartridge containing 0.05 g of silica gel in the bottom. After a clean-up of high and medium polarity interferences with water and an acetonitrile:water mixture, the OPPs were desorbed from the MSPD cartridge with pure acetonitrile and directly transferred to a dynamic mixing chamber for dilution with water and preconcentration into an SPE 20 mm × 2.0 mm I.D. C(18) silica column. Subsequently, the OPPs were eluted on-line with the chromatographic mobile phase to the analytical column and the diode array detector for their separation and detection, respectively. The method was validated and yielded recovery values between 91% and 101% and precision values, expressed as relative standard deviations (RSD), which were less than or equal to 12%. Linearity was good and ranged from 0.5 to 10 μg g(-1), and the limits of detection of the OPPs were in the range of 0.04-0.25 μg g(-1). The method was satisfactorily applied to the analysis of real samples and is recommended for food control, research efforts when sample amounts are limited, and laboratories that have ordinary chromatographic instrumentation. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Development of andrographolide molecularly imprinted polymer for solid-phase extraction

    NASA Astrophysics Data System (ADS)

    Yin, Xiaoying; Liu, Qingshan; Jiang, Yifan; Luo, Yongming

    2011-06-01

    A method employing molecularly imprinted polymer (MIP) as selective sorbent for solid-phase extraction (SPE) to pretreat samples was developed. The polymers were prepared by precipitation polymerization with andrographolide as template molecule. The structure of MIP was characterized and its static adsorption capacity was measured by the Scatchard equation. In comparison with C 18-SPE and non-imprinted polymer (NIP) SPE column, MIP-SPE column displays high selectivity and good affinity for andrographolide and dehydroandrographolide for extract of herb Andrographis paniculata ( Burm.f.) Nees (APN). MIP-SPE column capacity was 11.9 ± 0.6 μmol/g and 12.1 ± 0.5 μmol/g for andrographolide and dehydroandrographolide, respectively and was 2-3 times higher than that of other two columns. The precision and accuracy of the method developed were satisfactory with recoveries between 96.4% and 103.8% (RSD 3.1-4.3%, n = 5) and 96.0% and 104.2% (RSD 2.9-3.7%, n = 5) for andrographolide and dehydroandrographolide, respectively. Various real samples were employed to confirm the feasibility of method. This developed method demonstrates the potential of molecularly imprinted solid phase extraction for rapid, selective, and effective sample pretreatment.

  8. Molecularly imprinted solid-phase extraction coupled to liquid chromatography for determination of Sudan dyes in preserved beancurds.

    PubMed

    Yan, Hongyuan; Qiao, Jindong; Pei, Yuning; Long, Tao; Ding, Wen; Xie, Kun

    2012-05-01

    New molecularly imprinted microspheres synthesized by suspension polymerisation using phenylamine and naphthol as mimic template were successfully applied as selective sorbents for the solid-phase extraction used for the simultaneous determination of four Sudan dyes from preserved beancurd products. The obtained imprinted microspheres showed good recognition and selectivity to the four Sudan dyes in aqueous solution and the affinity could be easily controlled by adjusting the property of the solution. Under the selected experimental condition, the recoveries of the Sudan dyes in preserved beancurds at three spiked levels were ranged between 90.2-104.5% with the relative standard deviation of less than 6.8%. The limit of detection (LOD) and limit of quantification (LOQ) based on a signal-to-noise of 3 and 10 were in the range of 0.005-0.009μgg(-1) and 0.015-0.030μgg(-1), respectively. Comparing with alumina and C18-based extraction, the selectivity and repeatability of molecularly imprinted solid-phase extraction (MISPE) were obviously improved. This method could be potentially applied for the determination of Sudan dyes in complicated food samples. Copyright © 2011 Elsevier Ltd. All rights reserved.

  9. Optimization of matrix solid-phase dispersion for the rapid determination of salicylate and benzophenone-type UV absorbing substances in marketed fish.

    PubMed

    Tsai, Dung-Ying; Chen, Chien-Liang; Ding, Wang-Hsien

    2014-07-01

    A simple and effective method for the rapid determination of five salicylate and benzophenone-type UV absorbing substances in marketed fish is described. The method involves the use of matrix solid-phase dispersion (MSPD) prior to their determination by on-line silylation gas chromatography tandem mass spectrometry (GC-MS/MS). The parameters that affect the extraction efficiency were optimized using a Box-Behnken design method. The optimal extraction conditions involved dispersing 0.5g of freeze-dried powdered fish with 1.0g of Florisil using a mortar and pestle. This blend was then transferred to a solid-phase extraction (SPE) cartridge containing 1.0g of octadecyl bonded silica (C18), as the clean-up co-sorbent. The target analytes were then eluted with 7mL of acetonitrile. The extract was derivatized on-line in the GC injection-port by reaction with a trimethylsilylating (TMS) reagent. The TMS-derivatives were then identified and quantitated by GC-MS/MS. The limits of quantitation (LOQs) were less than 0.1ng/g. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Bioinspired Polyelectrolyte-Assembled Graphene-Oxide-Coated C18 Composite Solid-Phase Microextraction Fibers for In Vivo Monitoring of Acidic Pharmaceuticals in Fish.

    PubMed

    Qiu, Junlang; Chen, Guosheng; Liu, Shuqin; Zhang, Tianlang; Wu, Jiayi; Wang, Fuxin; Xu, Jianqiao; Liu, Yan; Zhu, Fang; Ouyang, Gangfeng

    2016-06-07

    A novel solid-phase microextraction (SPME) fiber was prepared by gluing poly(diallyldimethylammonium chloride) (PDDA) assembled graphene oxide (GO)-coated C18 composite particles (C18@GO@PDDA) onto a quartz fiber with polyaniline (PANI). The fiber surface coating was sequentially modified with bioinspired polynorepinephrine, which provided a smooth biointerface and makes the coating suitable for in vivo sampling. The novel custom-made coating was used to extract acidic pharmaceuticals, and high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) was employed for analysis. The custom-made coating exhibited a much higher extraction efficiency than the previously used commercial polydimethylsiloxane (PDMS) and polyacrylate (PA) coatings. The custom-made coating also possessed satisfactory stability (the relative standard deviations (RSDs) ranged from 1.60% to 10.3% for six sampling-desorption cycles), interfiber reproducibility (the RSDs ranged from 2.61% to 11.5%), and resistance to matrix effects. The custom-made fibers were used to monitor the presence of acid pharmaceuticals in dorsal-epaxial muscle of living fish, and satisfactory sensitivities (limits of detection ranged from 0.13 ng/g to 7.56 ng/g) were achieved. The accuracies were verified by the comparison with liquid extraction. Moreover, the novel fibers were successfully used to monitor the presence of acidic pharmaceuticals in living fish, which demonstrated that the custom-made fibers were feasible for possible long-term in vivo continuous pharmaceutical monitoring.

  11. Automated solid-phase extraction of phenolic acids using layered double hydroxide-alumina-polymer disks.

    PubMed

    Ghani, Milad; Palomino Cabello, Carlos; Saraji, Mohammad; Manuel Estela, Jose; Cerdà, Víctor; Turnes Palomino, Gemma; Maya, Fernando

    2018-01-26

    The application of layered double hydroxide-Al 2 O 3 -polymer mixed-matrix disks for solid-phase extraction is reported for the first time. Al 2 O 3 is embedded in a polymer matrix followed by an in situ metal-exchange process to obtain a layered double hydroxide-Al 2 O 3 -polymer mixed-matrix disk with excellent flow-through properties. The extraction performance of the prepared disks is evaluated as a proof of concept for the automated extraction using sequential injection analysis of organic acids (p-hydroxybenzoic acid, 3,4-dihydroxybenzoic acid, gallic acid) following an anion-exchange mechanism. After the solid-phase extraction, phenolic acids were quantified by reversed-phase high-performance liquid chromatography with diode-array detection using a core-shell silica-C18 stationary phase and isocratic elution (acetonitrile/0.5% acetic acid in pure water, 5:95, v/v). High sensitivity and reproducibility were obtained with limits of detection in the range of 0.12-0.25 μg/L (sample volume, 4 mL), and relative standard deviations between 2.9 and 3.4% (10 μg/L, n = 6). Enrichment factors of 34-39 were obtained. Layered double hydroxide-Al 2 O 3 -polymer mixed-matrix disks had an average lifetime of 50 extractions. Analyte recoveries ranged from 93 to 96% for grape juice and nonalcoholic beer samples. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Semi-permeable surface analytical reversed-phase column for the improved trace analysis of acidic pesticides in water with coupled-column reversed-phase liquid chromatography with UV detection. Determination of bromoxynil and bentazone in surface water.

    PubMed

    Hogendoorn, E A; Westhuis, K; Dijkman, E; Heusinkveld, H A; den Boer, A C; Evers, E A; Baumann, R A

    1999-10-08

    The coupled-column (LC-LC) configuration consisting of a 3 microm C18 column (50 x 4.6 mm I.D.) as the first column and a 5 microm C18 semi-permeable-surface (SPS) column (150 x 4.6 mm I.D.) as the second column appeared to be successful for the screening of acidic pesticides in surface water samples. In comparison to LC-LC employing two C18 columns, the combination of C18/SPS-C18 significantly decreased the baseline deviation caused by the hump of the co-extracted humic substances when using UV detection (217 nm). The developed LC-LC procedure allowed the simultaneous determination of the target analytes bentazone and bromoxynil in uncleaned extracts of surface water samples to a level of 0.05 microg/l in less than 15 min. In combination with a simple solid-phase extraction step (200 ml of water on a 500 mg C18-bonded silica) the analytical procedure provides a high sample throughput. During a period of about five months more than 200 ditch-water samples originating from agricultural locations were analyzed with the developed procedure. Validation of the method was performed by randomly analyzing recoveries of water samples spiked at levels of 0.1 microg/l (n=10), 0.5 microg/l (n=7) and 2.5 microg/l (n=4). Weighted regression of the recovery data showed that the method provides overall recoveries of 95 and 100% for bentazone and bromoxynil, respectively, with corresponding intra-laboratory reproducibilities of 10 and 11%, respectively. Confirmation of the analytes in part of the samples extracts was carried out with GC-negative ion chemical ionization MS involving a derivatization step with bis(trifluoromethyl)benzyl bromide. No false negatives or positives were observed.

  13. [Determination of deoxynivalenol in grain and its products by solid-phase extraction coupled with high performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Huang, Juan; Chen, Guosong; Zhang, Xiaoyan; Shen, Chongyu; Lü, Chen; Wu, Bin; Liu, Yan; Chen, Huilan; Ding, Tao

    2012-11-01

    A method was established for the determination of deoxynivalenol (vomitoxin) in grain and its products based on solid-phase extraction coupled with high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). The sample was firstly extracted by acetonitrile-water (84:16, v/v). The extract was then cleaned-up by an HLB solid phase extraction cartridge. The separation was carried out on a Phenomenex Kinetex C18 column (100 mm x4. 6 mm, 2.6 microm) with a gradient elution using 0.3% per hundred ammonia solution-acetonitrile as mobile phases. The analysis of deoxynivalenol was performed under electrospray negative ionization mode. The limit of detection (LOD, S/N= 3) and the limit of quantification (LOQ, S/N = 10) were 20 microg/kg and 50 microg/kg, respectively. A good linearity (r > 0.99) was achieved for the target compound over the range of 20-1000 pg/L. The recoveries at the three spiked levels (50, 100, 500 microg/kg) in the blank matrices such as flour, barley, soybean, rice, cornmeal, cassava and wheat, were varied from 75.6% to 111.0% with the relative standard deviations no more than 13. 0%. The method is accurate, efficient, sensitive and practical. The cost of pretreatment is obviously reduced by replacing immunoaffinity columns and Mycosep columns with HLB columns which have the same purification effect.

  14. Extraction of chemical warfare agents from water with hydrophilic-lipophilic balance and C18 cartridges: comparative study.

    PubMed

    Kanaujia, Pankaj K; Pardasani, Deepak; Gupta, A K; Dubey, D K

    2007-01-19

    Efficient extraction of chemical warfare agents (CWAs) from water is essential before subjecting them to gas chromatographic and spectral analysis aiming towards verification of the Chemical Weapons Convention (CWC). It requires development of fast, reliable, simple and reproducible sample preparation of CWAs from water which is likely to be contaminated during deliberate or inadvertent spread of CWAs. This work describes development of a solid-phase extraction method using hydrophilic-lipophilic balance (HLB) cartridges for extraction of CWAs from water. The extraction efficiencies of HLB and C18 cartridges were compared and the results revealed that HLB sorbents performed better. Extracts were analyzed by gas chromatography-mass spectrometry. Extraction parameters, such as extraction solvent, its volume and rinsing solvent were optimized. Best recoveries of target analytes were obtained using 1mL methanol and limits of detection were achieved up to 0.05microg/mL with dichloromethane. Precision of the method was found to be less than 9.2% RSD.

  15. Determination of N-(trans-4-isopropylcyclohexylcarbonyl)-D-phenylalanine in human plasma by solid-phase extraction and column-switching high-performance liquid chromatography with ultraviolet detection.

    PubMed

    Ono, I; Matsuda, K; Kanno, S

    1996-04-12

    A column-switching high-performance liquid chromatography method with ultraviolet detection at 210 nm has been developed for the determination of N-(trans-4-isopropylcyclohexylcarbonyl)-D-phenylalanine (AY4166, I) in human plasma. Plasma samples were prepared by solid-phase extraction with Sep-Pak Light tC18, followed by HPLC. The calibration graph for I was linear in the range 0.1-20 micrograms/ml. The limit of quantitation of I, in plasma, was 0.05 microgram/ml. The recovery of spiked I (0.5 microgram/ml) to drug-free plasma was over 92% and the relative standard deviation of spiked I (0.5 microgram/ml) compared to drug-free plasma was 4.3% (n = 8).

  16. Determination of pesticides in waters by automatic on-line solid-phase extraction-capillary electrophoresis.

    PubMed

    Hinsmann, P; Arce, L; Ríos, A; Valcárcel, M

    2000-01-07

    The separation of seven pesticides by micellar electrokinetic capillary chromatography in spiked water samples is described, allowing the analysis of pesticides mixtures down to a concentration of 50 microg l(-1) in less than 13 min. Calibration, pre-concentration, elution and injection into the sample vial was carried out automatically by a continuous flow system (CFS) coupled to a capillary electrophoresis system via a programmable arm. The whole system was electronically coupled by a micro-processor and completely controlled by a computer. A C18 solid-phase mini-column was used for the pre-concentration, allowing a 12-fold enrichment (as an average value) of the pesticides from fortified water samples. Under the optimal extraction conditions, recoveries between 90 and 114% for most of the pesticides were obtained.

  17. Determination of cobalt species in nutritional supplements using ICP-OES after microwave-assisted extraction and solid-phase extraction.

    PubMed

    Bartosiak, Magdalena; Jankowski, Krzysztof; Giersz, Jacek

    2018-06-05

    Cobalt content (as vitamin B 12 and inorganic cobalt) in two nutritional supplements, namely Spirulina platensis and Saccharomyces cerevisiae known as a "superfood", has been determined using inductively coupled plasma optical emission spectrometry (ICP-OES). Several sample pre-treatment protocols have been applied and compared. Microwave-assisted acid digestion efficiently decomposed all cobalt-containing compounds, thus allowed obtaining total cobalt content in supplements examined. Vitamin B 12 was extracted from the samples with acetate buffer and potassium cyanide solution exposed to mild microwave radiation for 30 min, and cyanocobalamin was separated from the extract by on-column solid phase extraction using C-18 modified silica bed. About 100% of cobalt species was extracted using the triple microwave-assisted extraction procedure. Total cobalt content was 20-fold greater in Spirulina tablets than the declared cobalamin content (as Co). The ICP-OES method precision was about 3% and detection limit was 1.9 and 2.7 ng Co mL -1 for inorganic cobalt or cyanocobalamin, respectively. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Determination of chiral pharmaceuticals and illicit drugs in wastewater and sludge using microwave assisted extraction, solid-phase extraction and chiral liquid chromatography coupled with tandem mass spectrometry.

    PubMed

    Evans, Sian E; Davies, Paul; Lubben, Anneke; Kasprzyk-Hordern, Barbara

    2015-07-02

    This is the first study presenting a multi-residue method allowing for comprehensive analysis of several chiral pharmacologically active compounds (cPACs) including beta-blockers, antidepressants and amphetamines in wastewater and digested sludge at the enantiomeric level. Analysis of both the liquid and solid matrices within wastewater treatment is crucial to being able to carry out mass balance within these systems. The method developed comprises filtration, microwave assisted extraction and solid phase extraction followed by chiral liquid chromatography coupled with tandem mass spectrometry to analyse the enantiomers of 18 compounds within all three matrices. The method was successfully validated for 10 compounds within all three matrices (amphetamine, methamphetamine, MDMA, MDA, venlafaxine, desmethylvenlafaxine, citalopram, metoprolol, propranolol and sotalol), 7 compounds validated for the liquid matrices only (mirtazapine, salbutamol, fluoxetine, desmethylcitalopram, atenolol, ephedrine and pseudoephedrine) and 1 compound (alprenolol) passing the criteria for solid samples only. The method was then applied to wastewater samples; cPACs were found at concentration ranges in liquid matrices of: 1.7 ng L(-1) (metoprolol) - 1321 ng L(-1) (tramadol) in influent,

  19. Comparison of several solid-phase extraction sorbents for continuous determination of amines in water by gas chromatography-mass spectrometry.

    PubMed

    Jurado-Sánchez, Beatriz; Ballesteros, Evaristo; Gallego, Mercedes

    2009-08-15

    A semiautomatic method has been proposed for the determination of different types of amines in water samples including anilines, chloroanilines, N-nitrosamines and aliphatic amines. The analytes were retained on a solid-phase extraction sorbent column and after elution, 1 microL of the extract was analysed by gas chromatography coupled with electron impact ionization mass spectrometry. A systematic overview is given of the advantages and disadvantages of several sorbents (LiChrolut EN, Oasis HLB, RP-C(18), graphitized carbon black, fullerenes and nanotubes) in the retention of amine compounds and based on sensitivity, selectivity and reliability. The retention efficiency for the studied amines was higher (ca. 100%) with LiChrolut EN and Oasis HLB than it was with RP-C(18) and fullerenes (53 and 62%, respectively, on average). Detection limits of 0.5-16 ng L(-1) for the 27 amines studied were obtained when using a sorbent column containing 75 mg of LiChrolut EN for 100mL of sample, the RSD being lower than 6.5%. The method was applied with good accuracy and precision in the determination of amines in various types of water including river, pond, tap, well, drinking, swimming pool and waste.

  20. Over-evaluation of total flavonoids in grape skin extracts containing sulphur dioxide.

    PubMed

    Corona, Onofrio; Squadrito, Margherita; Vento, Giorgia; Tirelli, Antonio; Di Stefano, Rocco

    2015-04-01

    Sulphur dioxide (SO2) proved to increase absorbance at 280 nm of grape skin and seed extracts containing it, diluted with ethanol-HCl to assess total flavonoids and anthocyanins in the same analysis. Additional absorbance at 280 nm was also observed in acetone:H2O extracts, if the acetone had not completely evaporated before the extracts were diluted with a solvent. Flavonoids were correctly quantified in the extracts when SO2 or acetone were removed by solid-phase extraction with a C18 RP as sorbent and methanol as eluting solvent. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Multiplexed Colorimetric Solid-Phase Extraction

    NASA Technical Reports Server (NTRS)

    Gazda, Daniel B.; Fritz, James S.; Porter, Marc D.

    2009-01-01

    Multiplexed colorimetric solid-phase extraction (MC-SPE) is an extension of colorimetric solid-phase extraction (C-SPE) an analytical platform that combines colorimetric reagents, solid phase extraction, and diffuse reflectance spectroscopy to quantify trace analytes in water. In CSPE, analytes are extracted and complexed on the surface of an extraction membrane impregnated with a colorimetric reagent. The analytes are then quantified directly on the membrane surface using a handheld diffuse reflectance spectrophotometer. Importantly, the use of solid-phase extraction membranes as the matrix for impregnation of the colorimetric reagents creates a concentration factor that enables the detection of low concentrations of analytes in small sample volumes. In extending C-SPE to a multiplexed format, a filter holder that incorporates discrete analysis channels and a jig that facilitates the concurrent operation of multiple sample syringes have been designed, enabling the simultaneous determination of multiple analytes. Separate, single analyte membranes, placed in a readout cartridge create unique, analyte-specific addresses at the exit of each channel. Following sample exposure, the diffuse reflectance spectrum of each address is collected serially and the Kubelka-Munk function is used to quantify each water quality parameter via calibration curves. In a demonstration, MC-SPE was used to measure the pH of a sample and quantitate Ag(I) and Ni(II).

  2. A simple solid-phase extraction method for the analysis of red cell phospholipids by liquid chromatography- tandem mass spectrometry.

    PubMed

    Nguyen, Van Long

    2018-02-25

    There has been increasing interest in the analysis of phospholipids in red blood cells as potential long-term biomarkers of different disease states. Here, we describe a simple method for the analysis of two phospholipids: 1-Palmitoyl-2-oleoyl-sn-glycero-3-phosphoethanol (PE 16:0/18:1) and 1-Palmitoyl-2-linoleoyl-sn-glycero-3-phosphoethanol (PE 16:/0/18:2) in erythrocytes by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Whole blood samples were removed free of plasma and washed in isotonic saline. Red cells were lysed with ultrapure water. Lysate samples were processed using a hybrid solid-phase extraction (SPE) phospholipid cartridge (1 mL, 30 mg). Both PE 16:0/18:1 and PE 16:0/18:2 and their deuterated internal standards were separated on an ACE C4 (150 mm × 2.1 mm, 2.7 μm particle size) by gradient elution at a flow rate of 0.5 mL per minute using mobile phases consisting of 0.01 mol/L ammonium acetate in: water (A), methanol (B), and isopropanol (C). The phospholipid species were quantified by the following transitions: PE 16:0/18:1: 701.5→281.3 and PE 16:0/18:2: 699.5→279.3. Both PE species displayed linearity ranging from 10 to 500 μg/L. The coefficient of variation (CV%) of PE 16:0/18:1 concerning intraday and interday precision was between 1.9%-2.6% and 3.0%-4.3%, respectively. For PE 16:0/18:2, this was between 1.8%-3.4% and 3.7%-4.1%, respectively. Both phospholipid species had accuracy (PE 16:0/18:1: 91%-98% and PE 16:0/18:2: 94%-103%) and extraction recovery (PE 16:0/18:1: 95%-106% and PE 16:0/18:2: 92%-102%) exceeding 90% over the analytical range. The limit of detection was 5 μg/L. Here we propose a simple SPE LC-MS/MS method for analyzing phospholipids in erythrocytes, which can be easily adopted. © 2018 Wiley Periodicals, Inc.

  3. Effectiveness of high-throughput miniaturized sorbent- and solid phase microextraction techniques combined with gas chromatography-mass spectrometry analysis for a rapid screening of volatile and semi-volatile composition of wines--a comparative study.

    PubMed

    Mendes, Berta; Gonçalves, João; Câmara, José S

    2012-01-15

    In this study the feasibility of different extraction procedures was evaluated in order to test their potential for the extraction of the volatile (VOCs) and semi-volatile constituents (SVOCs) from wines. In this sense, and before they could be analysed by gas chromatography-quadrupole first stage masss spectrometry (GC-qMS), three different high-throughput miniaturized (ad)sorptive extraction techniques, based on solid phase extraction (SPE), microextraction by packed sorbents (MEPS) and solid phase microextraction (SPME), were studied for the first time together, for the extraction step. To achieve the most complete volatile and semi-volatile signature, distinct SPE (LiChrolut EN, Poropak Q, Styrene-Divinylbenzene and Amberlite XAD-2) and MEPS (C(2), C(8), C(18), Silica and M1 (mixed C(8)-SCX)) sorbent materials, and different SPME fibre coatings (PA, PDMS, PEG, DVB/CAR/PDMS, PDMS/DVB, and CAR/PDMS), were tested and compared. All the extraction techniques were followed by GC-qMS analysis, which allowed the identification of up to 103 VOCs and SVOCs, distributed by distinct chemical families: higher alcohols, esters, fatty acids, carbonyl compounds and furan compounds. Mass spectra, standard compounds and retention index were used for identification purposes. SPE technique, using LiChrolut EN as sorbent (SPE(LiChrolut EN)), was the most efficient method allowing for the identification of 78 VOCs and SVOCs, 63 and 19 more than MEPS and SPME techniques, respectively. In MEPS technique the best results in terms of number of extractable/identified compounds and total peak areas of volatile and semi-volatile fraction, were obtained by using C(8) resin whereas DVB/CAR/PDMS was revealed the most efficient SPME coating to extract VOCs and SVOCs from Bual wine. Diethyl malate (18.8±3.2%) was the main component found in wine SPE(LiChrolut EN) extracts followed by ethyl succinate (13.5±5.3%), 3-methyl-1-butanol (13.2±1.7%), and 2-phenylethanol (11.2±9.9%), while in SPME(DVB/CAR/PDMS) technique 3-methyl-1-butanol (43.3±0.6%) followed by diethyl succinate (18.9±1.6%), and 2-furfural (10.4±0.4%), are the major compounds. The major VOCs and SVOCs isolated by MEPS(C8) were 3-methyl-1-butanol (26.8±0.6%, from wine total volatile fraction), diethyl succinate (24.9±0.8%), and diethyl malate (16.3±0.9%). Regardless of the extraction technique, the highest extraction efficiency corresponds to esters and higher alcohols and the lowest to fatty acids. Despite some drawbacks associated with the SPE procedure such as the use of organic solvents, the time-consuming and tedious sampling procedure, it was observed that SPE(LiChrolut EN), revealed to be the most effective technique allowing the extraction of a higher number of compounds (78) rather than the other extraction techniques studied. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Analysis of some cytokinins in coconut (Cocos nucifera L.) water by micellar electrokinetic capillary chromatography after solid-phase extraction.

    PubMed

    Ge, Liya; Yong, Jean Wan Hong; Tan, Swee Ngin; Yang, Xin Hao; Ong, Eng Shi

    2004-09-03

    Micellar electrokinetic capillary chromatography (MECC) was developed for the separation of cytokinins including trans-zeatin, trans-zeatin-O-glucoside, dihydrozeatin, dihydrozeatin-O-glucoside, meta-topolin riboside, N6-isopentenyladenine and N6-benzylaminopurine. Under the optimum conditions, i.e. a combination of 10 mM phosphate and 10 mM borate as the running buffer containing 50 mM sodium dodecyl sulphate at pH 10.4, the separation of seven cytokinin standards was accomplished within 11 min. The C18 solid-phase extraction (SPE) method was used to pre-concentrate the putative cytokinins present in the coconut water. Following which, the eluate was further purified using mixed mode Oasis MCX SPE columns and this additional step helps to reduce matrix interference during MECC. After the two solid-phase extraction steps, the optimized MECC method was able to screen for certain cytokinins (zeatin-O-glucoside and dihydrozeatin-O-glucoside) present in coconut water. After this screening, the presence of zeatin-O-glucoside and dihydrozeatin-O-glucoside in coconut water was further confirmed by independent high-performance liquid chromatography and liquid chromatography-mass spectrometry experiments.

  5. Determination of pesticides in sewage sludge from an agro-food industry using QuEChERS extraction followed by analysis with liquid chromatography-tandem mass spectrometry.

    PubMed

    Ponce-Robles, Laura; Rivas, Gracia; Esteban, Belen; Oller, Isabel; Malato, Sixto; Agüera, Ana

    2017-10-01

    An analytical method was developed and validated for the determination of ten pesticides in sewage sludge coming from an agro-food industry. The method was based on the application of Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) extraction for solid sewage sludge and SPE extraction for sludge aqueous phase, followed by liquid chromatography (LC) coupled to hybrid quadrupole/linear ion trap mass spectrometry (QqLIT-MS). The QuEChERS method was reported 14 years ago and nowadays is mainly applied to the analysis of pesticides in food. More recent applications have been reported in other matrices as sewage sludge, but the complexity of the matrix makes necessary the optimization of the cleanup step to improve the efficiency of the analysis. With this aim, several dispersive solid-phase extraction cleanup sorbents were tested, choosing C18 + PSA as a d-SPE sorbent. The proposed method was satisfactorily validated for most compounds investigated, showing recoveries higher than 80% in most cases, with the only exception of prochloraz (71%) at low concentration level. Limits of quantification were lower than 40 ng l -1 in the aqueous phase and below 40 ng g -1 in the solid phase for the majority of the analytes. The method was applied to solid sludge and the sludge aqueous phase coming from an agro-food industry which processes fruits and vegetables. Graphical abstract Application of LC/MS/MS advanced analytical techniques for determination of pesticides contained in sewage sludge.

  6. Analysis of isothiazolinones in environmental waters by gas chromatography-mass spectrometry.

    PubMed

    Rafoth, Astrid; Gabriel, Sabine; Sacher, Frank; Brauch, Heinz-Jürgen

    2007-09-14

    This paper describes an analytical method for the determination of five biocides of isothiazolinone type (2-methyl-3-isothiazolinone (MI), 5-chloro-2-methyl-3-isothiazolinone (CMI), 1,2-benzisothiazolinone (BIT), 2-octyl-3-isothiazolinone (OI), 4,5-dichloro-2-octyl-3-isothiazolinone (DCOI)) in environmental waters. The method is based on pre-concentration of the analytes by solid-phase extraction onto a mixture of a polymeric material and RP-C18 material and subsequent determination by gas chromatography-mass spectrometry (GC-MS). One of the target compounds (BIT) is derivatised with diazomethane after pre-concentration to improve its chromatographic performance. The method was optimised with respect to pre-concentration conditions (liquid-liquid extraction versus solid-phase extraction, solid-phase material, elution solvent and volume) and extensively validated. Applying the method to surface waters, groundwaters, and drinking waters, limits of detection between 0.01 and 0.1 microg/l could be achieved and the repeatability was below 10% for all compounds except for MI. Additional investigations showed that the stability of the isothiazolinones in environmental waters is limited and sample storage at 4 degrees C is mandatory to preserve the target biocides. First investigations of influents and effluents of a wastewater treatment plant showed that conventional wastewater treatment exhibits a high efficiency for removal of the isothiazolinones. In river waters, the target isothiazolinones could not be detected.

  7. Analysis of imazaquin in soybeans by solid-phase extraction and high-performance liquid chromatography.

    PubMed

    Guo, C; Hu, J-Y; Chen, X-Y; Li, J-Z

    2008-02-01

    An analytical method for the determination imazaquin residues in soybeans was developed. The developed liquid/liquid partition and strong anion exchange solid-phase extraction procedures provide the effective cleanup, removing the greatest number of sample matrix interferences. By optimizing mobile-phase pH water/acetonitrile conditions with phosphoric acid, using a C-18 reverse-phase chromatographic column and employing ultraviolet detection, excellent peak resolution was achieved. The combined cleanup and chromatographic method steps reported herein were sensitive and reliable for determining the imazaquin residues in soybean samples. This method is characterized by recovery >88.4%, precision <6.7% CV, and sensitivity of 0.005 ppm, in agreement with directives for method validation in residue analysis. Imazaquin residues in soybeans were further confirmed by high performance liquid chromatography-mass spectrometry (LC-MS). The proposed method was successfully applied to the analysis of imazaquin residues in soybean samples grown in an experimental field after treatments of imazaquin formulation.

  8. Determination of dextromethorphan in human plasma using pipette tip solid-phase extraction and gas chromatography-mass spectrometry.

    PubMed

    Hasegawa, Chika; Kumazawa, Takeshi; Uchigasaki, Seisaku; Lee, Xiao-Pen; Sato, Keizo; Terada, Masaru; Kurosaki, Kunihiko

    2011-10-01

    Dextromethorphan was extracted from human plasma samples (100 μL) using MonoTip C(18) tips, which are packed with C(18)-bonded monolithic silica gel that is attached to the inside of the tip. The samples, which contained dextromethorphan and trimeprazine as an internal standard (IS), were mixed with 200 μL of distilled water and 50 μL of 1 mol/L glycine-sodium hydroxide buffer (pH 10). The mixture was extracted to the C(18) phase of the tip by 20 sequential aspirating/dispensing cycles using a manual micropipettor. The analytes retained on the C(18) phase were then eluted with methanol by five sequential aspirating/dispensing cycles. The eluate was injected directly into a gas chromatograph and detected by a mass spectrometer with selected ion monitoring in positive electron ionization mode. An Equity-5 fused silica capillary column (30 m × 0.32 mm i.d., film thickness 0.5 μm) gave adequate separation of the dextromethorphan, IS, and impurities. The recoveries of dextromethorphan and the IS spiked into plasma were >87.4%. The regression equation for dextromethorphan showed excellent linearity from 2.5 to 320 ng/mL of plasma, and the limit of detection was 1.25 ng/mL of plasma. The intraday and interday coefficients of variation were less than 10.5% and 14.7%, respectively. The accuracy ranged from 91.9% to 107%. The validated method was successfully used to quantify the plasma concentration of dextromethorphan in a human subject after oral administration of the drug. © Springer-Verlag 2011

  9. Determination of phenolic acids and flavonoids in raw propolis by silica-supported ionic liquid-based matrix solid phase dispersion extraction high performance liquid chromatography-diode array detection.

    PubMed

    Wang, Zhibing; Sun, Rui; Wang, Yuanpeng; Li, Na; Lei, Lei; Yang, Xiao; Yu, Aimin; Qiu, Fangping; Zhang, Hanqi

    2014-10-15

    The silica-supported ionic liquid (S-SIL) was prepared by impregnation and used as the dispersion adsorbent of matrix solid phase dispersion (MSPD) for the simultaneous extraction of eight phenolic acids and flavonoids, including caffeic acid, ferulic acid, morin, luteolin, quercetin, apigenin, chrysin, and kaempferide in raw propolis. High performance liquid chromatography with a Zorbax SB-C18 column (150mm×4.6mm, 3.5μm) was used for separation of the analytes. The mobile phase consisted of 0.2% phosphoric acid aqueous solution and acetonitrile and the flow rate of the mobile phase was 0.5mL/min. The experimental conditions for silica-supported ionic liquid-based matrix solid phase dispersion (S-SIL-based MSPD) were optimized. S-SIL containing 10% [C6MIM]Cl was used as dispersant, 20mL of n-hexane as washing solvent and 15mL of methanol as elution solvent. The ratio of S-SIL to sample was selected to be 4:1. The standard curves showed good linear relationship (r>0.9995). The limits of detection and quantification were in the range of 5.8-22.2ngmL(-1) and 19.2-74.0ngmL(-1), respectively. The relative standard deviations (RSDs) of intra-day and inter-day determination were lower than 8.80% and 11.19%, respectively. The recoveries were between 65.51% and 92.32% with RSDs lower than 8.95%. Compared with ultrasound-assisted extraction (UAE) and soxhlet extraction, the present method consumed less sample, organic solvent, and extraction time, although the extraction yields obtained by S-SIL-based MSPD are slightly lower than those obtained by UAE. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Preliminary evaluation of new polymer matrix for solid-phase extraction of nonylphenol from water samples.

    PubMed

    Guerreiro, António; Soares, Ana; Piletska, Elena; Mattiasson, Bo; Piletsky, Sergey

    2008-03-31

    Molecularly imprinted (MIP) and blank polymers with affinity for nonylphenol were designed using computational modelling. Chromatographic tests demonstrated higher affinity of imprinted polymers towards the template nonylphenol as compared with blank polymers. The performance of both polymers in solid-phase extraction was however very similar. Both blank and imprinted polymers appeared to be suitable for the removal and pre-concentration of nonylphenol from contaminated water samples with 99% efficiency of the recovery. The commercial resins PH(EC) (Biotage) and C18 (Varian) tested in the same conditions used for comparative purposes had recovery rate <84%. The polymer capacity for nonylphenol was 231 mg g(-1) for blank and 228 mg g(-1) for MIP. The synthesised materials can have significance for sample pre-concentration and environmental analysis of this class of compounds.

  11. Development of a solid-phase extraction method for determination of pheophorbide a and pyropheophorbide a in health foods by liquid chromatography.

    PubMed

    Oshima, Harumi; Ueno, Eiji; Saito, Isao; Matsumoto, Hiroshi

    2004-01-01

    A simple solid-phase extraction (SPE) method was developed for the liquid chromatography (LC) determination of pheophorbide (Phor) a and pyropheophorbide (Pyro) a in health foods such as chlorella, spirulina, etc. The food sample was extracted with 85% (v/v) acetone. The extract was acidified with hydrochloric acid and loaded on a C18 cartridge. After washing with water, Phor a and Pyro a were eluted with the LC mobile phase. Phor a and Pyro a were separated by isocratic reversed-phase LC and quantitated by fluorescence detection. The recoveries for spiked samples of chlorella and the extract were 87.1-102.0%. Commercial health foods (chlorella, spirulina, aloe, kale, Jews mallow, and green tea leaves) were analyzed using the SPE method. The values found for Phor a and Pyro a ranged from 2 to 788 microg/g and from <1 to 24 microg/g, respectively. There was no significant difference between the SPE method and the official method in Japan (spectrophotometry after liquid-liquid extraction). The advantages of the SPE method are the short extraction times, lack of emulsions, and reduced consumption of organic solvents compared with the official method in Japan. The SPE method is considered to be useful for the screening of Phor a and Pyro a in health foods.

  12. Poly(methyloctylsiloxane) immobilized on silica as a sorbent for solid-phase extraction of some pesticides.

    PubMed

    Vigna, Camila R M; Morais, Lais S R; Collins, Carol H; Jardim, Isabel C S F

    2006-05-12

    A laboratory-made sorbent for solid-phase extraction (SPE) was obtained by thermal immobilization of poly(methyloctylsiloxane) (PMOS) onto silica. Cartridges packed with the new sorbent were used for the simultaneous determination of imazethapyr, nicosulfuron, diuron, linuron and chlorimuron-ethyl in water. These pesticides were separated and quantified using high-performance liquid chromatography with diode array detection (HPLC-DAD). The recoveries achieved with the laboratory-made PMOS cartridges were compared with those of some commercially available silica-based and polymer-based cartridges having C18, C8 and NH(2) pendant groups. Method validation using the laboratory-made sorbent was performed for the five pesticides at three fortifications levels (1x, 2x and 10x the limit of quantification of each pesticide). The laboratory-made PMOS cartridge has low cost preparation and showed good recoveries (72-111%) for all pesticides. Repeatability and intermediate precision were lower than 15%. Its performance was similar or even better, in some cases, than those of the commercial cartridges.

  13. Simultaneous determination of emamectin and ivermectin residues in Atlantic salmon muscle by liquid chromatography with fluorescence detection.

    PubMed

    van de Riet, J M; Brothers, N N; Pearce, J N; Burns, B G

    2001-01-01

    A liquid chromatographic (LC) method for determining residues of the antiparasitic drugs emamectin (EMA) and ivermectin (IVR) in fish tissues has been developed. EMA and IVR residues are extracted with acetonitrile and cleaned up on a C18 solid-phase extraction column. Extracts are derivatized with 1-methylimidazole and trifluoroacetic anhydride and the components are determined by LC on a C18 reversed-phase column with fluorescence detection (excitation: 365 nm, emission: 470 nm). The mobile phase is 94% acetonitrile-water run isocratically. Calibration curves were linear between 1 and 32 ng injected for both EMA and IVR. The limit of detection for both analytes was 0.5 ng/g, with a limit of quantitation of 1.5 ng/g. Recoveries of EMA and IVR added to salmon muscle averaged 96 +/- 9% and 86 +/- 6%, respectively, at levels between 5 and 80 ng/g. The percent relative standard deviation for the described method was less than 7% over the range of concentrations studied. The operational errors, interferences, and recoveries for fortified samples compare favorably with an established IVR method. The recommended method is simple, rapid, and specific for monitoring residues of EMA and IVR in Atlantic salmon muscle.

  14. Silica-based ionic liquid coating for 96-blade system for extraction of aminoacids from complex matrixes.

    PubMed

    Mousavi, Fatemeh; Pawliszyn, Janusz

    2013-11-25

    1-Vinyl-3-octadecylimidazolium bromide ionic liquid [C18VIm]Br was prepared and used for the modification of mercaptopropyl-functionalized silica (Si-MPS) through surface radical chain-transfer addition. The synthesized octadecylimidazolium-modified silica (SiImC18) was characterized by thermogravimetric analysis (TGA), infrared spectroscopy (IR), (13)C NMR and (29)Si NMR spectroscopy and used as an extraction phase for the automated 96-blade solid phase microextraction (SPME) system with thin-film geometry using polyacrylonitrile (PAN) glue. The new proposed extraction phase was applied for extraction of aminoacids from grape pulp, and LC-MS-MS method was developed for separation of model compounds. Extraction efficiency, reusability, linearity, limit of detection, limit of quantitation and matrix effect were evaluated. The whole process of sample preparation for the proposed method requires 270min for 96 samples simultaneously (60min preconditioning, 90min extraction, 60min desorption and 60min for carryover step) using 96-blade SPME system. Inter-blade and intra-blade reproducibility were in the respective ranges of 5-13 and 3-10% relative standard deviation (RSD) for all model compounds. Limits of detection and quantitation of the proposed SPME-LC-MS/MS system for analysis of analytes were found to range from 0.1 to 1.0 and 0.5 to 3.0μgL(-1), respectively. Standard addition calibration was applied for quantitative analysis of aminoacids from grape juice and the results were validated with solvent extraction (SE) technique. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Determination of polycyclic aromatic hydrocarbons in kerosene and bio-kerosene soot.

    PubMed

    Andrade-Eiroa, Auréa; Leroy, Valérie; Dagaut, Philippe; Bedjanian, Yuri

    2010-03-01

    Here we report a new, efficient and reliable analytical methodology for sensitive and selective quantification of Polycyclic Aromatic Hydrocarbons (PAHs) in soot samples. The methodology developed is based on ultrasonic extraction of the soot-bound PAHs into small volumes of acetonitrile, purification of the extracts through C(18) Solid Phase Extraction (SPE) cartridges and analysis by Reverse Phase Liquid Chromatography (RPLC) with UV and fluorimetric detection. For the first time, we report the convenience of adapting the SPE procedure to the nature of the soot samples. As a matter of fact, extracts containing high percentage of unpolar material are recommended to be cleaned with acetone, whereas extracts poor in unpolar compounds can be efficiently cleaned with methanol. The method was satisfactorily applied to kerosene and bio-kerosene soot from atmospheric open diffusion flames (pool fires) and premixed flames achieving Quantification and Detection limits in the range ng mg(-1) soot and recoveries about 90% for most of the PAHs studied. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  16. Solid cation exchange phase to remove interfering anthocyanins in the analysis of other bioactive phenols in red wine.

    PubMed

    da Silva, Letícia Flores; Guerra, Celito Crivellaro; Klein, Diandra; Bergold, Ana Maria

    2017-07-15

    Bioactive phenols (BPs) are often targets in red wine analysis. However, other compounds interfere in the liquid chromatography methods used for this analysis. Here, purification procedures were tested to eliminate anthocyanin interference during the determination of 19 red-wine BPs. Liquid chromatography, coupled to a diode array detector (HPLC-DAD) and a mass spectrometer (UPLC-MS), was used to compare the direct injection of the samples with solid-phase extractions: reversed-phase (C18) and strong cation-exchange (SCX). The HPLC-DAD method revealed that, out of 13BPs, only six are selectively analyzed with or without C18 treatment, whereas SCX enabled the detection of all BPs. The recovery with SCX was above 86.6% for eight BPs. Moreover, UPLC-MS demonstrated the potential of SCX sample preparation for the determination of 19BPs. The developed procedure may be extended to the analysis of other red wine molecules or to other analytical methods where anthocyanins may interfere. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Hot Chili Peppers: Extraction, Cleanup, and Measurement of Capsaicin

    NASA Astrophysics Data System (ADS)

    Huang, Jiping; Mabury, Scott A.; Sagebiel, John C.

    2000-12-01

    Capsaicin, the pungent ingredient of the red pepper or Capsicum annuum, is widely used in food preparation. The purpose of this experiment was to acquaint students with the active ingredients of hot chili pepper (capsaicin and dihydrocapsaicin), the extraction, cleanup, and analysis of these chemicals, as a fun and informative analytical exercise. Fresh peppers were prepared and extracted with acetonitrile, removing plant co-extractives by addition to a C-18 solid-phase extraction cartridge. Elution of the capsaicinoids was accomplished with a methanol-acetic acid solution. Analysis was completed by reverse-phase HPLC with diode-array or variable wavelength detection and calibration with external standards. Levels of capsaicin and dihydrocapsaicin were typically found to correlate with literature values for a specific hot pepper variety. Students particularly enjoyed relating concentrations of capsaicinoids to their perceived valuation of "hotness".

  18. [Determination of perfluoroalkyl acids in lamb liver by high performance liquid chromatography- tandem mass spectrometry combined with dispersive solid phase extraction].

    PubMed

    Zhu, Pingping; Yue, Zhenfeng; Zheng, Zongkun; Zhang, Yi; Li, Wenyin; Zhao, Fengjuan; Xiao Chengui; Bai, Runye; Lin, Wei

    2015-05-01

    A method was developed for the determination of 19 perfluoroalkyl acids (PFAs) in lamb liver by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/ MS) combined with dispersive solid phase extraction. The sample was extracted with acidified acetonitrile, and then cleaned-up by a mixture of N-propylethylenediamine (PSA), C18 and graphitized carbon black (GCB) sorbents. The 19 PFAs were analyzed by HPLC-MS/MS with a C18 chromatographic column, adopting the multiple reaction monitoring (MRM) mode with negative electrospray ionization. The effects of the dosages of hydrochloric acid and the sorbents on the recoveries of the 19 PFAs were studied. For accurate quantitative analysis, the isotope internal standard method was used. The calibration curves were linear with the correlation coefficients over 0.998 in the range of 0.05-20 µg/kg for the 19 PFAs. The limits of detection were 0.004-0.111 µg/kg. The limits of quantification were 0.012-0.370 µg/kg. The mean recoveries of the 19 PFAs at spiked levels of 0.5, 1.0, 2.0 µg/kg were in the range from 80% to 128% with the relative standard deviations of 0.31%-11.1%. The developed method is rapid, simple, accurate. It is suitable for the determination of the 19 PFAs in large quantities of lamb liver samples.

  19. Laboratory study of the response of select insecticides to toxicity identification evaluation procedures

    USGS Publications Warehouse

    Kuivila, Kathryn; Crepeau, Kathryn L.

    1999-01-01

    A laboratory study was used to evaluate the response of select insecticides to toxicity identification evaluation procedures. Fourteen insecticides, one degradation product, and one synergist were spiked into organic-grade water and carried through toxicity identification evaluation procedures. Concentrations of each compound were analyzed by gas chromatography/mass spectrometry. During Phase I, the water sample was pumped through a C-8 solid-phase extraction cartridge and then eluted with methanol. Dimethoate was not removed by the extraction, but remained in the rinsate. In contrast, permethrin was removed by the extraction, but was not recovered by the methanol elution, and 80 percent of the permethrin remained on the cartridge, teflon tubing, and glassware. Chlorpyrifos also was not recovered completely with the methanol elution (only 62 percent was recovered). The other insecticides were extracted by C-8 solid-phase extraction cartridge and recovered by elution with methanol (80 percent or greater). During Phase II, a new spiked water sample was extracted by C-8 solid-phase extraction cartridge and then eluted with varying concentrations of methanol and water into different fractions. Each methanol:water fraction was analyzed for the added compounds. Most of the insecticides eluted in two fractions, with concentrations of 10 percent or greater. The largest number of insecticides eluted in the 75 percent methanol:water fraction.

  20. Comprehensive analytical methodology to determine hydrocarbons in marine waters using extraction disks coupled to glass fiber filters and compound-specific isotope analyses.

    PubMed

    Ternon, Eva; Tolosa, Imma

    2015-07-24

    Solid-phase extraction of both aliphatic (AHs) and aromatic polycyclic hydrocarbons (PAHs) from seawater samples was evaluated using a GFF filter stacked upon an octadecyl bonded silica (C18) disk. Stable-isotope measurements were developed on hydrocarbons extracted from both GFF and C18-disks in order to characterize the source of hydrocarbons. A clear partition of hydrocarbon compounds between the dissolved and the particulate phase was highlighted. PAHs showed a higher affinity with the dissolved phase (recoveries efficiency of 48-71%) whereas AHs presented strong affinity with the particulate phase (up to 76% of extraction efficiency). Medium volumes of seawater samples were tested and no breakthrough was observed for a 5L sample. Isotopic fractionation was investigated within all analytical steps but none was evidenced. This method has been applied to harbor seawater samples and very low AH and PAH concentrations were achieved. Due to the low concentration levels of hydrocarbons in the samples, the source of hydrocarbons was determined by molecular indices rather than isotopic measurements and a pyrolytic origin was evidenced. The aliphatic profile also revealed the presence of long-chain linear alkylbenzenes (LABs). The methodology presented here would better fit to polluted coastal environments affected by recent oil spills. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Evaluation of eggshell membrane-based bio-adsorbent for solid-phase extraction of linear alkylbenzene sulfonates coupled with high-performance liquid chromatography.

    PubMed

    Wang, Weidong; Chen, Bo; Huang, Yuming; Cao, Jia

    2010-09-03

    The potential of eggshell membrane (ESM) as a novel solid-phase extraction bio-adsorbent was investigated in the present study. The ESM with a unique structure of intricate lattice network showed a predominant ability to capture linear alkylbenzene sulfonates (LAS) as a model of organic pollutants by the hydrophobic interactions between ESM and LAS molecular at pH very close to the isoelectric point of ESM, which was similar to the most widely used trapping mechanism for SPE. Under the optimal conditions, the breakthrough capacities of the ESM packed cartridge for C10-C13 LAS homologues were found to be 30, 53, 50, and 43microgg(-1), respectively. On the basis of high-performance liquid chromatography separation and UV detection of LAS homologues, the proposed system could respond down to 0.027ngmL(-1) of LAS with a linear calibration range from 0.2 to 100ngmL(-1), showing a good LAS enrichment ability of eggshell membrane biomaterial with high sensitivity, and could be successfully used for the detection of residual LAS in environmental water samples. The reproducibility among columns was satisfactory (RSD among columns is less than 10%). A comparison study with ESM, C8 and C18 as adsorbents for LAS demonstrated that ESM-based bio-adsorbent was advantageous over C8 and C18, the widely used traditional adsorbents. 2010 Elsevier B.V. All rights reserved.

  2. Efficient removal of recalcitrant deep-ocean dissolved organic matter during hydrothermal circulation

    NASA Astrophysics Data System (ADS)

    Hawkes, Jeffrey A.; Rossel, Pamela E.; Stubbins, Aron; Butterfield, David; Connelly, Douglas P.; Achterberg, Eric P.; Koschinsky, Andrea; Chavagnac, Valérie; Hansen, Christian T.; Bach, Wolfgang; Dittmar, Thorsten

    2015-11-01

    Oceanic dissolved organic carbon (DOC) is an important carbon pool, similar in magnitude to atmospheric CO2, but the fate of its oldest forms is not well understood. Hot hydrothermal circulation may facilitate the degradation of otherwise un-reactive dissolved organic matter, playing an important role in the long-term global carbon cycle. The oldest, most recalcitrant forms of DOC, which make up most of oceanic DOC, can be recovered by solid-phase extraction. Here we present measurements of solid-phase extractable DOC from samples collected between 2009 and 2013 at seven vent sites in the Atlantic, Pacific and Southern oceans, along with magnesium concentrations, a conservative tracer of water circulation through hydrothermal systems. We find that magnesium and solid-phase extractable DOC concentrations are correlated, suggesting that solid-phase extractable DOC is almost entirely lost from solution through mineralization or deposition during circulation through hydrothermal vents with fluid temperatures of 212-401 °C. In laboratory experiments, where we heated samples to 380 °C for four days, we found a similar removal efficiency. We conclude that thermal degradation alone can account for the loss of solid-phase extractable DOC in natural hydrothermal systems, and that its maximum lifetime is constrained by the timescale of hydrothermal cycling, at about 40 million years.

  3. Double-disk solid-phase extraction--Simultaneous cleanup and trace enrichment of herbicides and metabolites from environmental samples

    USGS Publications Warehouse

    Ferrar, Imma; Barceló, Damià; Thurman, E.M.

    1999-01-01

    Phenylurea and triazine herbicides, including some metabolites, were isolated from water and soil extracts by solid-phase extraction using a layered system of two extraction disks, a method called double-disk solid-phase extraction. The first disk consisted of strong anion exchange (SAX) of 10-μm styrene divinylbenzene (SDB) particles embedded in Teflon, and the second disk was a C18 disk of 10-μm particles also embedded in Teflon. A volume of 500 mL of water or aqueous soil extract is passed through the layered system with the SAX disk first. The purpose of the SAX disk is to remove the humic and fulvic acids from the water or aqueous soil extract by ion exchange through their carboxyl groups. Even during methanol elution of herbicides, the humic substances remain bound to the SAX disk with >85% retention. Elution with methanol results in more than 90% recovery of the herbicides from the layered extraction disks. Removal of the humic and fulvic acids results in greater sensitivity for diode array detection quantitation (0.05 μg/L for herbicides) by substantially reducing the absorbance of the humic peak on the LC chromatogram. The herbicides adsorb to the SAX disk either through hydrogen bonding to the anion-exchange sites or by hydrophobic interaction with the SDB surface of the anion-exchange disk. The method was tested for the analysis of natural water samples from the Mississippi Embayment, a cotton-growing area of the southeastern United States.

  4. A new screening method for amphetamine and methamphetamine using dansyl chloride derivatization and cartridge fluorescence.

    PubMed

    Yamada, H; Ikeda-Wada, S; Oguri, K

    1998-07-01

    A new screening method for amphetamines was developed. It consists of derivatization with dansyl chloride, extraction of the derivative using a Sep-Pak C18 or a Bond Elut C18, solid phase extraction columns, and visualization of the fluorescence of the cartridge. A control test using drug-free urine showed no fluorescence. Amphetamine, methamphetamine and the methylenedioxy derivatives exhibited strong fluorescence, while related compounds, such as N-ethylamphetamine and fenetylline, were negative or weakly positive. The disadvantage of the present method is that it is a multi-step procedure and 20-30 min is required for screening. However, since it has a different specificity from the widely used immunochemical technique, it is suggested to be a useful screen for amphetamines.

  5. The Potential of Graphene as an Adsorbent for Five Pesticides from Different Classes in Rape Oil Samples Using Dispersive Solid-Phase Extraction.

    PubMed

    Madej, Katarzyna; Janiga, Katarzyna; Piekoszewski, Wojciech

    2018-01-01

    Isolation conditions for five pesticides (metazachlor, tebuconazole, λ -cyhalothrin, chlorpyrifos, and deltamethrin) from rape oil samples were examined using the dispersive solid-phase graphene extraction technique. To determine the optimal extraction conditions, a number of experimental factors (amount of graphene, amount of salt, type and volume of the desorbing solvent, desorption time with and without sonication energy, and temperature during desorption) were studied. The compounds of interest were separated and detected by an HPLC-UV employing a Kinetex XB-C18 column and a mobile phase consisting of acetonitrile and water flowing in a gradient mode. The optimized extraction conditions were: the amount of graphene 15 mg, desorbing solvent (acetonitrile) 5 mL, time desorption 10 min at 40°C, and amount of NaCl 1 g. The detection limit for metazachlor, tebuconazole, λ -cyhalothrin, and chlorpyrifos was 62.5 ng·g -1 , and for deltamethrin, it was 500 ng·g -1 . The obtained results lead to the conclusion that graphene may be successfully used for the isolation of the five pesticides from rape oil. However, their determination at low concentration levels, as they occur in real oil samples, requires the employment of appropriately highly sensitive analytical methods, as well as a more suitable graphene form (e.g., magnetically modified graphene).

  6. Multi-walled carbon nanotubes-dispersive solid-phase extraction combined with liquid chromatography-tandem mass spectrometry for the analysis of 18 sulfonamides in pork.

    PubMed

    Hou, Xiao-Lin; Wu, Yin-Liang; Yang, Ting; Du, Xiang-Dang

    2013-06-15

    A simple and cost-effective pre-treatment procedure was developed for 18 sulfonamides in pork using dispersive solid phase extraction (dSPE) with multi-walled carbon nanotubes (MWCNTs). The sample was analysed after purification by ultra high-performance liquid chromatography-positive electrospray ionisation tandem mass spectrometry (UHPLC-ESI-MS/MS). After extraction with phosphate buffer (pH 6.0), a dSPE procedure was conducted with MWCNTs. The pH value of the extract, extraction time with MWCNTs, type and amount of MWCNTs and type of eluent were optimised to increase the sample throughput and sensitivity. The samples were quantified using sulfamethazine-(13)C6 as an internal standard. The recoveries of the target compounds from the pork samples were most efficient when 150mg of MWCNTs with an outer diameter of less than 8nm and a length of 0.5-2μm was used. A mixture of acetonitrile/50mM ammonium acetate (95:5, v/v) was shown to be the most suitable solvent for desorbing the compounds from the MWCNTs. The proposed method was validated according to the European Commission Decision 2002/657/EC, which determines linearity, specificity, decision limit (CCα), detection capability (CCβ), recovery, precision and stability. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Analysis of molybdenum, tungsten, and vanadium in surface water of the Atlantic Ocean using solid phase extraction with 8-hydroxyquinoline and ICP MS determination

    NASA Astrophysics Data System (ADS)

    Rimskaya-Korsakova, M. N.; Berezhnaya, E. D.; Dubinin, A. V.

    2017-07-01

    An analytical technique is proposed to determine ultratrace concentrations of Mo, V, and W found in seawater using mass spectrometry with inductively coupled plasma (ICP MS) after preliminary concentration by solid-phase extraction of metal complexes with 8-hydroxyquinoline (8-HQ) on C18 octadecyl silica. The technique utilizes 150 mL of a water sample. A preconcentration factor 50 is obtained. The detection limits are 0.25 nmol/kg, 0.041 nmol/kg, and 5 pmol/kg for Mo, V, and W, respectively. Dissolved Mo, V, and Wconcentrations in surface seawater from Atlantic Ocean transect were determined. The concentrations ranges along the transect were: 91-108 nmol/kg for Mo, 28-35 nmol/kg for V, and 55-75 pmol/kg for W. The Mo/W ratio varied from 1300 to 1800.

  8. Hydrophilic interaction liquid chromatography-solid phase extraction directly combined with protein precipitation for the determination of triptorelin in plasma.

    PubMed

    Wang, Jixia; Kong, Song; Yan, Jingyu; Jin, Gaowa; Guo, Zhimou; Shen, Aijin; Xu, Junyan; Zhang, Xiuli; Zou, Lijuan; Liang, Xinmiao

    2014-06-01

    Peptide drugs play a critical role in therapeutic treatment. However, as the complexity of plasma, determination of peptide drugs using liquid chromatography-tandem mass spectrometry (LC-MS/MS) is a daunting task. To solve this problem, hydrophilic interaction liquid chromatography-solid phase extraction (HILIC-SPE) directly combined with protein precipitation (PPT) was developed for the selective extraction of triptorelin from plasma. The extracts were analyzed by reversed-phase liquid chromatography (RPLC). Proteins, phospholipids and highly polar interferences could be removed from plasma by the efficient combination of PPT, HILIC-SPE and RPLC-MS/MS. This method was evaluated by matrix effect, recovery and process efficiency at different concentration levels (50, 500 and 5,000 ng/mL) of triptorelin. Furthermore, the performance of HILIC-SPE was compared with that of reversed-phase C18 SPE and hydrophilic lipophilic balance (Oasis HLB) SPE. Among them, HILIC-SPE provided the minimum matrix effect (ranging from 96.02% to 103.41%), the maximum recovery (ranging from 80.68% to 90.54%) and the satisfactory process efficiency (ranging from 82.83% to 92.95%). The validated method was successfully applied to determine triptorelin in rat plasma. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Determination and validation of a simple high-performance liquid chromatographic method for simultaneous assay of iprodione and vinclozolin in human urine.

    PubMed

    Carlucci, Giuseppe; Pasquale, Dorina Di; Ruggieri, Fabrizio; Mazzeo, Pietro

    2005-12-15

    A method based on solid-phase extraction (SPE) and high-performance liquid chromatography (HPLC) was developed for the simultaneous determination of 3-(3,5-diclorophenyl)-5-ethenyl-5-methyl-2,4-oxazolidinedione (vinclozolin) and 3-(3,5-diclorophenyl)-N-(1-methylethyl)-2,4-dioxo-1-imidazolidinecarboxamide (iprodione) in human urine. Urine samples containing vinclozolin and iprodione were collected by solid phase extraction using C(18) cartridges. The chromatographic separation was achieved on a Spherisorb ODS2 (250 mm x 4.6 mm, 5 microm) column with an isocratic mobile phase of acetonitrile-water (60:40, v/v). Detection was UV absorbance at 220 nm. The calibration graphs were linear from 30 to 1000 ng/mL for the two fungicides. Intra- and inter-day R.S.D. did not exceed 2.9%. The quantitation limit was 50 ng/mL for vinclozolin and 30 ng/mL for iprodione, respectively.

  10. Analysis of Free Amino Acids in Different Extracts of Orthosiphon stamineus Leaves by High-Performance Liquid Chromatography Combined with Solid-Phase Extraction.

    PubMed

    Shafaei, Armaghan; Halim, Nor Hidayah Ab; Zakaria, Norhidayah; Ismail, Zhari

    2017-10-01

    Orthosiphon stamineus (OS) Benth is a medicinal plant and native in Southeast Asia. Previous studies have shown that OS leaves possess antioxidant, cytotoxic, diuretic, antihypertensive, and uricosuric effects. These beneficial effects have been attributed to the presence of primary and secondary metabolites such as polyphenols, amino acids, and flavonoids. To develop and validate an high-performance liquid chromatography (HPLC)-diode array detector (DAD) method combined with solid-phase extraction that involves precolumn derivatization with O -phthaladehyde for simultaneous analysis of free amino acids in OS leaves extracts. OS leaves were extracted with water (OS-W), ethanol (OS-E), methanol (OS-M), 50% ethanol (OS-EW), and 50% methanol (OS-MW). The extracts were treated by C18 cartridge before derivatization, resulting in great improvement of separation by Zorbox Eclipse XDB-C 18 column. The HPLC-DAD method was successfully developed and validated for analyzing the contents of free amino acids in OS extracts. The results showed that l-aspartic acid with 0.93 ± 0.01 nmol/mg was the major free amino acid in OS-W extract. However, in OS-E, OS-M, OS-EW, and OS-MW, l-glutamic acid with 3.53 ± 0.16, 2.17 ± 0.10, 4.01 ± 0.12, and 2.49 ± 0.12 nmol/mg, respectively, was the major free amino acid. Subsequently, l-serine, which was detected in OS-W, OS-E, and OS-M, was the minor free amino acid with 0.33 ± 0.02, 0.12 ± 0.01, and 0.06 ± 0.01 nmol/mg, respectively. However, l-threonine with 0.26 ± 0.02 and 0.19 ± 0.08 nmol/mL in OS-EW and OS-MW, respectively, had the lowest concentration compared with other amino acid components. All validation parameters of the developed method indicate that the method is reliable and efficient to simultaneously determine the free amino acids content for routine analysis of OS extracts. The HPLC-DAD method combined with solid phase extraction was successfully developed and validated for simultaneous determination and quantification of 17 free amino acids in Orthosiphon stamineus (OS) Benth extractsOS extracts were found to be rich in free amino acid contentL-aspartic acid was the major free amino acid in OS water extract while, in OS ethanol, methanol, 50% ethanol and 50% methanol extracts, L-glutamic acid was the major free amino acidL-serine was the minor free amino acid in OS water, ethanol and methanol extracts while, in OS 50% ethanol and 50% methanol extracts, L-threonine had the lowest concentration compared to other amino acid components. Abbreviations used: HPLC-DAD: High-Performance Liquid Chromatography with Diode-Array Detection, OS: Orthosiphon stamineus , OS-W: Orthosiphon stamineus water extract, OS-E: Orthosiphon stamineus ethanol extract, OS-M: Orthosiphon stamineus methanol extract, OS-EW: Orthosiphon stamineus 50% ethanol extract, OS-MW: Orthosiphon stamineus 50% methanol extract, OPA: O-phthaladehyde , SPE: Solid Phase Extraction, UV: Ultraviolet, LOD: Limit of Detection, LOQ: Limit of Quantification, RSD: Relative Standard Deviation.

  11. Magnetic metal-organic frameworks for fast and efficient solid-phase extraction of six Sudan dyes in tomato sauce.

    PubMed

    Shi, Xin-Ran; Chen, Xue-Lei; Hao, Yu-Lan; Li, Li; Xu, Hou-Jun; Wang, Man-Man

    2018-06-01

    Magnetic solid-phase extraction is an effective and useful technique to preconcentrate trace analytes from food samples. In this study, a magnetic trimeric chromium octahedral metal-organic framework (Fe 3 O 4 -NH 2 @MIL-101) was fabricated and characterized. Fe 3 O 4 -NH 2 @MIL-101 was applied as an adsorbent of magnetic solid-phase extraction combined with high performance liquid chromatography to effectively isolate and simultaneously determine six Sudan dyes (Para Red, Sudan I-IV, and Sudan Red 7B) from tomato sauce. Potential factors affecting the MSPE were investigated in detail, and adsorption efficiency of Fe 3 O 4 -NH 2 @MIL-101 was compared with those of conventional adsorbents, such as neutral alumina, HLB, and C 18 . The developed method facilitated the extraction with using only 3 mg of adsorbent in 2 min. In addition, enhancement factors of 50, linear range of 0.01-25 μg/mL, and detection limit (S/N = 3) of 0.5-2.5 μg/kg were obtained. The intra-day and inter-day recoveries for spiked Sudan dyes were in the range of 72.6%-92.9% and 69.6%-91.6%, respectively, with relative standard deviations of ≤9.2%. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Carboxylated graphene oxide/polyvinyl chloride as solid-phase extraction sorbent combined with ion chromatography for the determination of sulfonamides in cosmetics.

    PubMed

    Zhong, Zhixiong; Li, Gongke; Luo, Zhibin; Liu, Zhe; Shao, Yijuan; He, Wanwen; Deng, Jianchao; Luo, Xingling

    2015-08-12

    A carboxylated graphene oxide/polyvinyl chloride (CGO/PVC) material was prepared as a sorbent for the selective extraction of sulphonamides from complex sample. After being dispersed in buffer solution, sample was transferred into the prefabricated solid-phase extraction (SPE) column, which integrated extraction and cleanup into one single-step. A multi-response optimization based on the Box-Behnken design was used to optimize factors affecting extraction efficiency. Compared with the commonly commercial sorbents including MCX, WCX and C18, CGO/PVC hybrid material had higher extraction selectivity and capacity to sulphonamides. The limits of detection and quantification for seven target compounds were in the range of 3.4-7.1 μg/L and 11.4-23.7 μg/L, respectively. The self-assembly SPE cartridge was successfully used to enrich seven analytes in anti-acne cosmetics prior to ion chromatography detection with good recoveries of 87.8-102.0% and relative standard deviations of 1.2-6.4%, implying that this method was suitable for routine analysis of cosmetics. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Methods of Analysis by the U.S. Geological Survey National Water Quality Laboratory - Determination of Moderate-Use Pesticides and Selected Degradates in Water by C-18 Solid-Phase Extraction and Gas Chromatography/Mass Spectrometry

    USGS Publications Warehouse

    Sandstrom, Mark W.; Stroppel, Max E.; Foreman, William T.; Schroeder, Michael P.

    2001-01-01

    A method for the isolation and analysis of 21 parent pesticides and 20 pesticide degradates in natural-water samples is described. Water samples are filtered to remove suspended particulate matter and then are pumped through disposable solid-phase-extraction columns that contain octadecyl-bonded porous silica to extract the analytes. The columns are dried by using nitrogen gas, and adsorbed analytes are eluted with ethyl acetate. Extracted analytes are determined by capillary-column gas chromatography/mass spectrometry with selected-ion monitoring of three characteristic ions. The upper concentration limit is 2 micrograms per liter (?g/L) for most analytes. Single-operator method detection limits in reagent-water samples range from 0.00 1 to 0.057 ?g/L. Validation data also are presented for 14 parent pesticides and 20 degradates that were determined to have greater bias or variability, or shorter holding times than the other compounds. The estimated maximum holding time for analytes in pesticide-grade water before extraction was 4 days. The estimated maximum holding time for analytes after extraction on the dry solid-phase-extraction columns was 7 days. An optional on-site extraction procedure allows for samples to be collected and processed at remote sites where it is difficult to ship samples to the laboratory within the recommended pre-extraction holding time. The method complements existing U.S. Geological Survey Method O-1126-95 (NWQL Schedules 2001 and 2010) by using identical sample preparation and comparable instrument analytical conditions so that sample extracts can be analyzed by either method to expand the range of analytes determined from one water sample.

  14. Comparative evaluation of liquid-liquid extraction, solid-phase extraction and solid-phase microextraction for the gas chromatography-mass spectrometry determination of multiclass priority organic contaminants in wastewater.

    PubMed

    Robles-Molina, José; Gilbert-López, Bienvenida; García-Reyes, Juan F; Molina-Díaz, Antonio

    2013-12-15

    The European Water Framework Directive (WFD) 2000/60/EC establishes guidelines to control the pollution of surface water by sorting out a list of priority substances that involves a significant risk to or via the aquatic systems. In this article, the analytical performance of three different sample preparation methodologies for the GC-MS/MS determination of multiclass organic contaminants-including priority comprounds from the WFD-in wastewater samples using gas chromatography-mass spectrometry was evaluated. The methodologies tested were: (a) liquid-liquid extraction (LLE) with n-hexane; (b) solid-phase extraction (SPE) with C18 cartridges and elution with ethyl acetate:dichloromethane (1:1 (v/v)), and (c) headspace solid-phase microextraction (HS-SPME) using two different fibers: polyacrylate and polydimethylsiloxane/carboxen/divinilbenzene. Identification and confirmation of the selected 57 compounds included in the study (comprising polycyclic aromatic hydrocarbons (PAHs), pesticides and other contaminants) were accomplished using gas chromatography tandem mass spectrometry (GC-MS/MS) with a triple quadrupole instrument operated in the multiple reaction monitoring (MRM) mode. Three MS/MS transitions were selected for unambiguous confirmation of the target chemicals. The different advantages and pitfalls of each method were discussed. In the case of both LLE and SPE procedures, the method was validated at two different concentration levels (15 and 150 ng L(-1)) obtaining recovery rates in the range 70-120% for most of the target compounds. In terms of analyte coverage, results with HS-SPME were not satisfactory, since 14 of the compounds tested were not properly recovered and the overall performance was worse than the other two methods tested. LLE, SPE and HS-SPME (using polyacrylate fiber) procedures also showed good linearity and precision. Using any of the three methodologies tested, limits of quantitation obtained for most of the detected compounds were in the low nanogram per liter range. © 2013 Elsevier B.V. All rights reserved.

  15. Pipette tip solid-phase extraction and high-performance liquid chromatography for the determination of flavonoids from Epimedii herba in rat serum and application of the technique to pharmacokinetic studies.

    PubMed

    Wang, Nani; Huang, Xiaowen; Wang, Xuping; Zhang, Yang; Wu, Renjie; Shou, Dan

    2015-05-15

    Epimedii herba is a traditional Chinese medicine for the treatment of osteoporosis. Epimedin A, B and C and icariin are the primary effective ingredients of this medicine. In this study, a simple and low-cost method based on pipette tip solid-phase extraction, high-performance liquid chromatography separation, and diode array detection has been developed for the simultaneous analysis of four flavonoids (epimedin A, B and C and icariin) from Epimedii herba in rat serum samples. In this novel extraction configuration, the sorbents were placed between a filter (hollow fiber) and the pipette tip. Pipette tip solid-phase extraction has several advantages compared to conventional extraction methods: faster extraction time (6.0min); lower sample volume (100μL); lower solvent volume (100μL); and less solvent waste. Under the optimum extraction conditions, the method showed good linearity (0.05-10.0μgmL(-1)), acceptable intra- and inter precision (RSD<6%), low limits of quantification (0.027-0.045μgmL(-1)) and satisfactory relative recoveries (98.63-103.18%). This method was successfully applied to investigate the pharmacokinetics of the major flavonoids in Epimedii herba extract after oral administration to rats (10gkg(-1) body weight). The primary pharmacokinetic parameters for rats were determined as follows: Cmax, 0.45-4.11μgmL(-1); Tmax, 0.21-0.26h; t1/2α, 0.06-0.12h; t1/2β, 2.02-3.48h; AUC0-∞: 0.50-2.58μghmL(-1); CL, 19.53-44.72Lkg(-1)h(-1); and MRT0-∞, 2.25-3.77h. The developed method has the potential to promulgate the pharmacokinetics and provide more information for clinical applications. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. On-line solid phase extraction coupled to capillary LC-ESI-MS for determination of fluoxetine in human blood plasma.

    PubMed

    Saber, Amr L

    2009-04-15

    An instrumental setup including on-line solid phased extraction coupled to capillary liquid chromatography-electrospray ionization-mass spectrometry (SPE-capLC-ESI-MS) has been constructed to improve the sensitivity for quantification of fluoxetine hydrochloride in human plasma. Prior to injection, 0.5 mL of plasma spiked with metronidazole (internal standard) was mixed with ammonium formate buffer for effective chloroform liquid-liquid extraction. The method was validated in the range 5-60 ng mL(-1) fluoxetine, yielding a correlation coefficient of 0.999 (r(2)). The within-assay and between-assay precisions were between (8.5 and 11%) and (6.6 and 7.5%), respectively. The method was used to determine the amount of fluoxetine in a healthy male 14 h after an intake of one capsule of the antidepressant and anorectic Flutin, which contains 20mg fluoxetine per each capsule. Fluoxetine was detected, and the concentration was calculated to 9.0 ng mL(-1) plasma. In the preliminary experiments, conventional LC-UV instrumentation was employed. However, it was found that employing a capillary column with an inner diameter of (0.3mm I.D. x 50 mm, Zorbax C(18)) increased the sensitivity by a factor of approximately 100, when injecting the same mass of analyte. Incorporating an easily automated C(18) reversed phase column switching system with SPE (1.0mm I.D. x 5.0mm, 5 microm) made it possible to inject up to 100 microL of solution, and the total analysis time was 5.5 min.

  17. Applicability of multisyringe chromatography coupled to on-line solid-phase extraction to the simultaneous determination of dicamba, 2,4-D, and atrazine.

    PubMed

    Chávez-Moreno, C A; Guzmán-Mar, J L; Hinojosa-Reyes, L; Hernández-Ramírez, A; Ferrer, L; Cerdà, V

    2012-07-01

    Simultaneous determination of three herbicides (dicamba, 2,4-D, and atrazine) has been achieved by on-line solid-phase extraction (SPE) coupled to multisyringe chromatography (MSC) with UV detection. The preconcentration conditions were optimized; a preconcentration flow rate of 0.5 mL min(-1) and elution at 0.8 mL min(-1) were the optimum conditions. A C(18) (8 mm i.d.) membrane extraction disk conditioned with 0.3 mol L(-1) HCl in 0.5% MeOH was used. A 3-mL sample was preconcentrated, then eluted with 0.43 mL 40:60 water-MeOH. A C(18) monolithic column (25 mm × 4.6 mm) was used for chromatographic separation. Separation of the three compounds was achieved in 10 min by use of 0.01% aqueous acetic acid-MeOH (60:40) as mobile phase at a flow rate of 0.8 mL min(-1). The limits of detection (LOD) were 13, 57, and 22 μg L(-1) for dicamba, 2,4-D, and atrazine, respectively. The sampling frequency was three analyses per hour, and each analysis consumed only 7.3 mL solvent. The method was applied to spiked water samples, and recovery between 85 and 112% was obtained. Recovery was significantly better than in the conventional HPLC-UV method. These results indicated the reliability and accuracy of this flow-based method. This is the first time this family of herbicides has been simultaneously analyzed by on-line SPE-MSC using a monolithic column.

  18. [Simultaneous determination of sixteen perfluorinated organic compounds in surface water by solid phase extraction and ultra performance liquid chromatography with electrospray ionization tandem mass spectrometry].

    PubMed

    Zhang, Ming; Tang, Fangliang; Yu, Yayun; Chen, Feng; Xu, Jianfen; Ye, Yonggen

    2014-05-01

    A high-throughput detection method has been developed for the determination of sixteen perfluorinated organic compounds (PFCs) in surface water by solid phase extraction-ultra performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (SPE-UPLC-ESI-MS/MS). The water samples were concentrated and purified through WAX solid phase extraction cartridges. The UPLC separation was performed on an ACQUITY UPLC BEH C18 column utilizing a gradient elution program of methanol (containing 2 mmol/L ammonium acetate) and water (containing 2 mmol/L ammonium acetate) as the mobile phases at a flow rate of 0.4 mL/min. The MS/MS detection was performed under negative electrospray ionization ( ESI ) in multiple reaction monitoring (MRM) mode. Good linearities were observed in the range of 0.5-100 gg/L or 1.0 - 100 microg/L with correlation coefficients from 0.998 7 to 0.999 9. The limits of detection (LODs) for the sixteen perfluorinated organic compounds were in the range of 0.06-0.46 ng/L. The recoveries ranged from 67.6% to 103% with the relative standard deviations between 2.94% and 12.0%. This method was characterized by high sensitivity and precision, extensive range and high speed, and can be applied for the analysis of PFC contaminants in surface water.

  19. [Determination of wilforine in honey using solid phase extraction purification and ultra performance liquid chromatography-tanden mas spectrometry].

    PubMed

    Lei, Meikang; Peng, Fang; Ding, Tao; Zhu, Zitong; Xu, Jiawen; Wu, Xiaoqin

    2015-01-01

    A method based on solid phase extraction and ultra performance liquid chromatography coupled with tandem mass spectrometry (SPE-UPLC-MS/MS) has been proposed for the determination of wilforine residue in honey. After the sample was dissolved with water, concentrated and purified by an HLB solid phase extraction cartridge, the UPLC separation was performed on a Hypersil GOLD C18 column (50 mm x 2.1 mm, 1.9 microm) utilizing a gradient elution program of methanol (containing 0.15% formic acid) and water as mobile phases at a flow rate of 0. 25 mL/min. The determination was carried out with electrospray ion source in the positive mode (ESI) and multiple reaction monitoring (MRM) mode. The mass concentration of wilforine in the range of 0.01-2 microg/L was linearly correlated with the peak area, and the correlation coefficients was greater than 0.998. The limit of quantification (S/N>10) for wilforine was 0.01 microg/kg. The recoveries were 76.1% to 96.2% in the spiked levels of 0.01, 0.05 and 0.5 microg/kg with the relative standard deviations (RSD, n=6) lower than 10%. The results indicate that the method is rapid, sensitive and accurate, and can be applied for the qualitative and quantitative analysis of wilforine in honey.

  20. Determination of alachlor and its sulfonic acid metabolite in water by solid-phase extraction and enzyme-linked immunosorbent assay

    USGS Publications Warehouse

    Aga, D.S.; Thurman, E.M.; Pomes, M.L.

    1994-01-01

    Solid-phase extraction (SPE) and enzyme-linked immunosorbent assay (ELISA) were combined for the trace analysis of the herbicide alachlor and its major soil metabolite, ethanesulfonic acid (ESA). The anti-alachlor antibody cross-reacted with ESA, which produced false-positive detections of alachlor in water samples by immunoassay screens. Alachlor and ESA were isolated from water by SPE on a C18 resin and eluted sequentially with ethyl acetate and methanol. Alachlor is soluble in ethyl acetate while the anionic ESA is not. Thus ESA remained adsorbed on the C18 resin and was eluted later with methanol. The combination of SPE with ELISA effectivety separated and quantified both alachlor and ESA using the same antibody for two ELISA methods. The general method may have applicability for the separation of other herbicides and their ionic metabolites. The SPE-ELISA method has a, detection limit of 0.01 ??g/L for alachlor and 0.05 ??g/L for ESA, with a precision of ?? 10%. Analyses of surface and ground water samples were confirmed by gas chromatography/mass spectrometry and high-performance liquid chromatography with photodiode-array detection. Results showed widespread occurrence of ESA in surface and ground water of the midwestern United States, with concentrations ranging from 10 ??g/L.

  1. Physically incorporated extraction phase of solid-phase microextraction by sol-gel technology.

    PubMed

    Liu, Wenmin; Hu, Yuan; Zhao, Jinghong; Xu, Yuan; Guan, Yafeng

    2006-01-13

    A sol-gel method for the preparation of solid-phase microextraction (SPME) fiber was described and evaluated. The extraction phase of poly(dimethysiloxane) (PDMS) containing 3% vinyl group was physically incorporated into the sol-gel network without chemical bonding. The extraction phase itself is then partly crosslinked at 320 degrees C, forming an independent polymer network and can withstand desorption temperature of 290 degrees C. The headspace extraction of BTX by the fiber SPME was evaluated and the detection limit of o-xylene was down to 0.26 ng/l. Extraction and determination of organophosphorus pesticides (OPPs) in water, orange juice and red wine by the SPME-GC thermionic specified detector (TSD) was validated. Limits of detection of the method for OPPs were below 10 ng/l except methidathion. Relative standard deviations (RSDs) were in the range of 1-20% for pesticides being tested.

  2. Cyclodextrin based polymer sorbents for micro-solid phase extraction followed by liquid chromatography tandem mass spectrometry in determination of endogenous steroids.

    PubMed

    Manaf, Normaliza Abdul; Saad, Bahruddin; Mohamed, Mohamed H; Wilson, Lee D; Latiff, Aishah A

    2018-03-30

    Sorbents were prepared by cross-linking β-cyclodextrin (β-CD) using two different types of cross-linker units at variable reactant mole ratios. The resulting polymers containing β-CD were evaluated as sorbents in micro-solid phase extraction (μ-SPE) format for the extraction of the endogenous steroids testosterone (T), epitestosterone (E), androsterone (A), etiocholanolone (Etio), 5α-androstane-3α,17β-diol (5αAdiol) and 5β-androstane-3α,17β-diol (5βAdiol). The best sorbent (C1; cyclodextrin polymer) showed superior extraction characteristics compared with commercial sorbents (C18 and Bond Elut Plexa). Parameters influencing the extraction efficiency of the C1 sorbent such as extraction and desorption times, desorption solvent and volume of sample were investigated. The extracts were separated using a Hypersil Gold column (50 × 2.1 mm, 1.9 μm) under gradient elution coupled to a LC-MS/MS. The compounds were successfully separated within 8 min. The method offers good repeatability (RSD < 10%) and linearity (r 2  > 0.995) were within the range of 1-200 ng mL -1 for T and E, 250-4000 ng mL -1 for A and Etio and 25-500 ng mL -1 for 5αAdiol and 5βAdiol, respectively. The method was applied for the determination of steroid profile of urine from volunteers. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. A simple and highly selective molecular imprinting polymer-based methodology for propylparaben monitoring in personal care products and industrial waste waters.

    PubMed

    Vicario, Ana; Aragón, Leslie; Wang, Chien C; Bertolino, Franco; Gomez, María R

    2018-02-05

    In this work, a novel molecularly imprinted polymer (MIP) proposed as solid phase extraction sorbent was developed for the determination of propylparaben (PP) in diverse cosmetic samples. The use of parabens (PAs) is authorized by regulatory agencies as microbiological preservative; however, recently several studies claim that large-scale use of these preservatives can be a potential health risk and harmful to the environment. Diverse factors that influence on polymer synthesis were studied, including template, functional monomer, porogen and crosslinker used. Morphological characterization of the MIP was performed using SEM and BET analysis. Parameters affecting the molecularly imprinted solid phase extraction (MISPE) and elution efficiency of PP were evaluated. After sample clean-up, the analyte was analyzed by high performance liquid chromatography (HPLC). The whole procedure was validated, showing satisfactory analytical parameters. After applying the MISPE methodology, the extraction recoveries were always better than 86.15%; the obtained precision expressed as RSD% was always lower than 2.19 for the corrected peak areas. Good linear relationship was obtained within the range 8-500ngmL -1 of PP, r 2 =0.99985. Lower limits of detection and quantification after MISPE procedure of 2.4 and 8ngmL -1 , respectively were reached, in comparison with previously reported methodologies. The development of MISPE-HPLC methodology provided a simple an economic way for accomplishing a clean-up/preconcentration step and the subsequent determination of PP in a complex matrix. The performance of the proposed method was compared against C-18 and silica solid phase extraction (SPE) cartridges. The recovery factors obtained after applying extraction methods were 96.6, 64.8 and 0.79 for MISPE, C18-SPE and silica-SPE procedures, respectively. The proposed methodology improves the retention capability of SPE material plus robustness and possibility of reutilization, enabling it to be used for PP routine monitoring in diverse personal care products (PCP) and environmental samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Facile preparation of raisin-bread sandwich-structured magnetic graphene/mesoporous silica composites with C18-modified pore-walls for efficient enrichment of phthalates in environmental water.

    PubMed

    Huang, Danni; Wang, Xianying; Deng, Chunhui; Song, Guoxin; Cheng, Hefa; Zhang, Xiangmin

    2014-01-17

    In this study, novel raisin-bread sandwich-structured magnetic graphene/mesoporous silica composites with C18-modified interior pore-walls (mag-graphene@mSiO2-C18) were synthesized by coating mesoporous silica layers onto each side of magnetic graphene through a surfactant-mediated co-condensation sol-gel process. The prepared functionalized nanocomposites possessed marvelous properties of extended plate-like morphology, fine water dispersibility, high magnetic response, large surface area (315.4cm(2)g(-1)), uniform pore size (3.3nm) and C18-modified interior pore-walls. Several kinds of phthalates were selected as model analytes to systematically evaluate the performance of adsorbents in extracting hydrophobic molecules followed by gas chromatography-mass spectrometry analyses. Various extraction parameters, including pH value of sample solution, amounts of adsorbents, adsorption time, species and volume of eluting solvent, and desorption time were optimized. The anti-interference ability to macromolecular proteins was also investigated. Method validations such as linearity, recovery, reproducibility, and limit of detection were also studied. Finally, mag-graphene@mSiO2-C18 composites were successfully applied to analyzing phthalates in environmental water samples. The results indicated that this novel approach offered an attractive alternative for rapid, convenient, efficient and selective magnetic solid-phase extraction for targeted hydrophobic compounds. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Liquid chromatographic determination of florfenicol in the plasma of multiple species of fish

    USGS Publications Warehouse

    Vue, C.; Schmidt, L.J.; Stehly, G.R.; Gingerich, W.H.

    2002-01-01

    A simple method was developed for determining florfenicol concentration in a small volume (250 mul) of plasma from five phylogenetically diverse species of freshwater fish. Florfenicol was isolated from the plasma matrix through C-18 solid-phase extraction and quantified by reversed-phase high-performance liquid chromatography with UV detection. The accuracy (84-104%), precision (%RSDless than or equal to8), and sensitivity (quantitation limit <30 ng/ml) of the method indicate its usefulness for conducting pharmacokinetic studies on a variety of freshwater fish. Published by Elsevier Science B.V.

  6. Effects of dissolved organic matter (DOM) sources and nature of solid extraction sorbent on recoverable DOM composition: Implication into potential lability of different compound groups.

    PubMed

    Chen, Meilian; Kim, Sunghwan; Park, Jae-Eun; Kim, Hyun Sik; Hur, Jin

    2016-07-01

    Noting the source-dependent properties of dissolved organic matter (DOM), this study explored the recoverable compounds by solid phase extraction (SPE) of two common sorbents (C18 and PPL) eluted with methanol solvent for contrasting DOM sources via fluorescence excitation-emission matrix coupled with parallel factor analysis (EEM-PARAFAC) and Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS). Fresh algae and leaf litter extracts DOM, one riverine DOM, and one upstream lacustrine DOM were selected for the comparison. C18 sorbent was generally found to extract more diverse molecular formula, relatively higher molecular weight, and more heteroatomic DOM compounds within the studied mass range than PPL sorbent except for the leaf litter extract. Even with the same sorbent, the main molecular features of the two end member DOM were distributed on different sides of the axes of a multivariate ordination, indicating the source-dependent characteristics of the recoverable compounds by the sorbents. In addition, further examination of the molecular formula uniquely present in the two end members and the upstream lake DOM suggested that proteinaceous, tannin-like, and heteroatomic DOM constituents might be potential compound groups which are labile and easily degraded during their mobilization into downstream watershed. This study provides new insights into the sorbent selectivity of DOM from diverse sources and potential lability of various compound groups.

  7. Determination of organochlorine pesticide and polychlorinated biphenyl residues in fatty fish by tandem solid-phase extraction cleanup.

    PubMed

    Schenck, F J; Calderon, L; Podhorniak, L V

    1996-01-01

    A rapid, multiresidue solid-phase extraction (SPE) technique for determination of organochlorine pesticide and polychlorinated biphenyl (PCB) residues in nonfatty fish was modified for use with fatty fish. In the modified procedures, samples are extracted with acetonitrile, and the extract is cleaned up with both C18 and Florisil SPE columns. Residues are determined by gas chromatography with electron capture detection. The original method was modified for use with fatty fish by reducing the amount of tissue extracted and by using an improved Florisil SPE cleanup. Recovery data are presented for 24 fortified organochlorine pesticide residues (0.12 ppm) and 3 fortified PCB residues (0.80 ppm) from flounder, bluefish, and shad samples, which contained 0.8, 5.4, and 22.6% fat, respectively. For the 3 types of fish, recoveries of 23 of 24 fortified organochlorine pesticide residues ranged from 55 to 129%, and recoveries of 3 fortified PCB residues ranged from 55 to 104%. There were no significant differences in recovery based on fish species and/or fat content for the majority of residues studied. This SPE method and the official AOAC method yielded comparable results for fish containing incurred organochlorine residues.

  8. Solid-phase Extraction Using Hierarchical Organosilicates for Enhanced Detection of Nitroenergetic Targets

    DTIC Science & Technology

    2011-01-01

    THIS PAGE unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 liquid or gas chromatography and do not Icnd themselves well...typically compatible with gas or liquid chromatography , and equilibration times can be lengthy. Other solid-phase extraction pTOtoools have utilized a...aniH M"X vr sat,~rat io~ of> an ~quifer o.r. soi ~. Surface water often contains from sea water was similar to recovery from deionized waier for ,:’ a

  9. Liquid chromatographic determination of the cyanobacterial toxin beta-n-methylamino-L-alanine in algae food supplements, freshwater fish, and bottled water.

    PubMed

    Scott, Peter M; Niedzwiadek, Barbara; Rawn, Dorothea F K; Lau, Ben P-Y

    2009-08-01

    Beta-N-Methylamino-L-alanine (BMAA) is a neurotoxin originally found in cycad seeds and now known to be produced by many species of freshwater and marine cyanobacteria. We developed a method for its determination in blue-green algae (BGA) food supplements, freshwater fish, and bottled water by using a strong cation-exchange, solid-phase extraction column for cleanup after 0.3 M trichloroacetic acid extraction of BGA supplements and fish. Bottled water was applied directly onto the solid-phase extraction column. For analysis of carbonated water, sonication and pH adjustment to 1.5 were needed. To determine protein-bound BMAA, the protein pellet left after extraction of the BGA supplement and fish was hydrolyzed by boiling with 6 M hydrochloric acid; BMAA was cleaned up on a C18 column and a strong cation-exchange, solid-phase extraction column. Determination of BMAA was by liquid chromatography of the fluorescent derivative formed with 9-fluorenylmethyl chloroformate. The method was validated by recovery experiments using spiking levels of 1.0 to 10 microg/g for BGA supplements, 0.5 to 5.0 microg/g for fish, and 0.002 microg/g for bottled water; mean recoveries were in the range of 67 to 89% for BGA supplements and fish, and 59 to 92% for bottled water. Recoveries of BMAA from spiked extracts of hydrolyzed protein from BGA supplements and fish ranged from 66 to 83%. The cleanup developed provides a useful method for surveying foods and supplements for BMAA and protein-bound BMAA.

  10. Electrical conductivity, differential scanning calorimetry, X-ray diffraction, and 7Li nuclear magnetic resonance studies of n-C x H(2 x+1)OSO3Li ( x = 12, 14, 16, 18, and 20)

    NASA Astrophysics Data System (ADS)

    Hirakawa, Satoru; Morimoto, Yoshiaki; Honda, Hisashi

    2015-04-01

    Electrical conductivity ( σ), differential scanning calorimetry (DSC), and X-ray diffraction (XRD) measurements of n-C x H (2 x+1) OSO 3Li ( x= 12, 14, 16, 18, and 20) crystals were performed as a function of temperature. In addition, σ, DSC, and XRD observations of n-C x H (2 x+1) OSO 3Na and n-C x H (2 x+1) OSO 3K ( x= 12, 14, 16, 18, and 20) crystals were carried out for comparison. DSC results of the salts revealed several solid-solid phase transitions with large entropy changes (Δ S). For n-C 18 H 37 OSO 3Li and n-C 20 H 41 OSO 3Li salts, each melting point produced a small Δ S mp value compared with the total entropy change in the solid phases (Δ S tr1+Δ S tr2). Additionally, Li + ion diffusion was detected in the highest temperature solid phases. For K salts, larger σ values were detected for potassium alkylsulfates compared with those reported for alkyl carboxylate. 7Li NMR spectra of n-C 18 H 37 OSO 3Li crystals recorded in the low-temperature phase showed large asymmetry parameters, suggesting the Li + ions are localized at asymmetric sites in the crystals.

  11. Analysis of sesquiterpene lactones, lignans, and flavonoids in wormwood (Artemisia absinthium L.) using high-performance liquid chromatography (HPLC)-mass spectrometry, reversed phase HPLC, and HPLC-solid phase extraction-nuclear magnetic resonance.

    PubMed

    Aberham, Anita; Cicek, Serhat Sezai; Schneider, Peter; Stuppner, Hermann

    2010-10-27

    Today, the medicinal use of wormwood (Artemisia absinthium) is enjoying a resurgence of popularity. This study presents a specific and validated high-performance liquid chromatography (HPLC)-diode array detection method for the simultaneous determination and quantification of bioactive compounds in wormwood and commercial preparations thereof. Five sesquiterpene lactones, two lignans, and a polymethoxylated flavonoid were baseline separated on RP-18 material, using a solvent gradient consisting of 0.085% (v/v) o-phosphoric acid and acetonitrile. The flow rate was 1.0 mL/min, and chromatograms were recorded at 205 nm. The stability of absinthin was tested exposing samples to light, moisture, and different temperatures. Methanolic and aqueous solutions of absinthin were found to be stable for up to 6 months. This was also the case when the solid compound was kept in the refrigerator at -35 °C. In contrast, the colorless needles, when stored at room temperature, turned yellow. Three degradation compounds (anabsin, anabsinthin, and the new dimer 3'-hydroxyanabsinthin) were identified by HPLC-mass spectrometry and HPLC-solid-phase extraction-nuclear magnetic resonance and quantified by the established HPLC method.

  12. Extraction of toxic compounds from saliva by magnetic-stirring-assisted micro-solid-phase extraction step followed by headspace-gas chromatography-ion mobility spectrometry.

    PubMed

    Criado-García, Laura; Arce, Lourdes

    2016-09-01

    A new sample extraction procedure based on micro-solid-phase extraction (μSPE) using a mixture of sorbents of different polarities (polymeric reversed-phase sorbent HLB, silica-based sorbent C18, and multiwalled carbon nanotubes) was applied to extract benzene, toluene, butyraldehyde, benzaldehyde, and tolualdehyde present in saliva to avoid interference from moisture and matrix components and enhance sensitivity and selectivity of the ion mobility spectrometry (IMS) methodology proposed. The extraction of target analytes from saliva samples by using μSPE were followed by the desorption step carried out in the headspace vials placed in the autosampler of the IMS device. Then, 200 μL of headspace was injected into the GC column coupled to the IMS for its analysis. The method was fully validated in terms of sensitivity, precision, and recovery. The LODs and LOQs obtained, when analytes were dissolved in saliva samples to consider the matrix effect, were within the range of 0.38-0.49 and 1.26-1.66 μg mL(-1), respectively. The relative standard deviations were <3.5 % for retention time and drift time values, which indicate that the method proposed can be applied to determine toxic compounds in saliva samples. Graphical abstract Summary of steps followed in the experimental set up of this work.

  13. Experimental design for extraction and quantification of phenolic compounds and organic acids in white "Vinho Verde" grapes.

    PubMed

    Dopico-García, M S; Valentão, P; Guerra, L; Andrade, P B; Seabra, R M

    2007-01-30

    An experimental design was applied for the optimization of extraction and clean-up processes of phenolic compounds and organic acids from white "Vinho Verde" grapes. The developed analytical method consisted in two steps: first a solid-liquid extraction of both phenolic compounds and organic acids and then a clean-up step using solid-phase extraction (SPE). Afterwards, phenolic compounds and organic acids were determined by high-performance liquid chromatography (HPLC) coupled to a diode array detector (DAD) and HPLC-UV, respectively. Plackett-Burman design was carried out to select the significant experimental parameters affecting both the extraction and the clean-up steps. The identified and quantified phenolic compounds were: quercetin-3-O-glucoside, quercetin-3-O-rutinoside, kaempferol-3-O-rutinoside, isorhamnetin-3-O-glucoside, quercetin, kaempferol and epicatechin. The determined organic acids were oxalic, citric, tartaric, malic, shikimic and fumaric acids. The obtained results showed that the most important variables were the temperature (40 degrees C) and the solvent (acid water at pH 2 with 5% methanol) for the extraction step and the type of sorbent (C18 non end-capped) for the clean-up step.

  14. Study of vortex-assisted MSPD and LC-MS/MS using alternative solid supports for pharmaceutical extraction from marketed fish.

    PubMed

    Hertzog, Gabriel I; Soares, Karina L; Caldas, Sergiane S; Primel, Ednei G

    2015-06-01

    A procedure based on vortex-assisted matrix solid-phase dispersion (MSPD) for the extraction of 15 pharmaceuticals from fish samples with determination by liquid chromatography-tandem mass spectrometry (LC-MS/MS) was validated. Florisil, C18, diatomaceous earth, chitin, and chitosan were evaluated as solid supports. Best results were obtained with 0.5 g of diatomaceous earth, 0.5 g of sodium sulfate, and 5 mL of methanol. Analytical recoveries ranged from 58 to 128 % with relative standard deviation (RSD) lower than 15 %. Limit of quantification (LOQ) values for the 15 compounds ranged from 5 to 1000 ng g(-1). The method under investigation has shown to be a simple and fast extraction tool with minimum instrumentation and low amount of reagent, resulting in method low cost. Besides, alternative materials, such as chitin and chitosan, which were applied to the dispersion step for the first time, were found to be interesting alternatives.

  15. Offline solid-phase extraction for preconcentration of pharmaceuticals and personal care products in environmental water and their simultaneous determination using the reversed phase high-performance liquid chromatography method.

    PubMed

    G Archana; Dhodapkar, Rita; Kumar, Anupama

    2016-09-01

    The present study reports a precise and simple offline solid-phase extraction (SPE) coupled with reversed-phase high-performance liquid chromatography (RP-HPLC) method for the simultaneous determination of five representative and commonly present pharmaceuticals and personal care products (PPCPs), a new class of emerging pollutants in the aquatic environment. The target list of analytes including ciprofloxacin, acetaminophen, caffeine benzophenone and irgasan were separated by a simple HPLC method. The column used was a reversed-phase C18 column, and the mobile phase was 1 % acetic acid and methanol (20:80 v/v) under isocratic conditions, at a flow rate of 1 mL min(-1). The analytes were separated and detected within 15 min using the photodiode array detector (PDA). The linearity of the calibration curves were obtained with correlation coefficients 0.98-0.99.The limit of detection (LOD), limit of quantification (LOQ), precision, accuracy and ruggedness demonstrated the reproducibility, specificity and sensitivity of the developed method. Prior to the analysis, the SPE was performed using a C18 cartridge to preconcentrate the targeted analytes from the environmental water samples. The developed method was applied to evaluate and fingerprint PPCPs in sewage collected from a residential engineering college campus, polluted water bodies such as Nag river and Pili river and the influent and effluent samples from a sewage treatment plant (STP) situated at Nagpur city, in the peak summer season. This method is useful for estimation of pollutants present in microquantities in the surface water bodies and treated sewage as compared to nanolevel pollutants detected by mass spectrometry (MS) detectors.

  16. Determination of melatonin content in traditional Thai herbal remedies used as sleeping aids.

    PubMed

    Padumanonda, Tanit; Johns, Jeffrey; Sangkasat, Autcharaporn; Tiyaworanant, Suppachai

    2014-01-06

    Melatonin content was screened in leaves of seven edible herbs used as sleeping aids in Thai traditional medicine. These plants are Piper nigrum L, Sesbania glandiflora (L.) Desv., Sesbania sesban (L.) Merr., Senna tora (L.) Roxb., Moringa oleifera Lam., Momordica charantia L. and Baccaurea ramiflora Lour. Dried leaves were extracted by sonication in methanol for six hours at room temperature, and then melatonin was purified by C18 solid phase extraction (SPE). Melatonin was then quantified by a validated RP-C18 HPLC method with fluorescent detection. Melatonin contents in extracts of B. ramiflora, S. glandiflora, M. charantia, S. tora and S. sesban were 43.2, 26.3, 21.4, 10.5 and 8.7 ng/g of dry sample weight, respectively. The highest melatonin content was from P. nigrum extract (1092.7 ng/g of dry sample weight). Melatonin was not detected in the extract of M. oleifera. Melatonin identification was confirmed by ELISA. Melatonin was found in six of the seven herbs in the traditional Thai sleeping recipe. One of these, P. nigrum, exhibited an encouragingly high amount of melatonin.

  17. Simultaneous determination of phenolic acids and flavonoids in rice using solid-phase extraction and RP-HPLC with photodiode array detection.

    PubMed

    Irakli, Maria N; Samanidou, Victoria F; Biliaderis, Costas G; Papadoyannis, Ioannis N

    2012-07-01

    An analytical method based on an optimized solid-phase extraction procedure and followed by high-performance liquid chromatography (HPLC) separation with diode array detection was developed and validated for the simultaneous determination of phenolic acids (gallic, protocatechuic, 4-hydroxy-benzoic, vanillic, caffeic, syringic, p-coumaric, ferulic, sinapic, and cinnamic acids), flavanols (catechin and epicatechin), flavonols (myricetin, quercetin, kaempferol, quercetin-3-O-glucoside, hyperoside, and rutin), flavones (luteolin and apigenin) and flavanones (naringenin and hesperidin) in rice flour (Oryza sativa L.). Chromatographic separation was carried out on a PerfectSil Target ODS-3 (250 mm × 4.6 mm, 3 μm) column at temperature 25°C using a mobile phase, consisting of 0.5% (v/v) acetic acid in water, methanol, and acetonitrile at a flow rate 1 mL min(-1) , under gradient elution conditions. Application of optimum extraction conditions, elaborated on both Lichrolut C(18) and Oasis HLB cartridges, have led to extraction of phenolic acids and flavonoids from rice flour with mean recoveries 84.3-113.0%. The developed method was validated in terms of linearity, accuracy, precision, stability, and sensitivity. Repeatability (n = 5) and inter-day precision (n = 4) revealed relative standard deviation (RSD) <13%. The optimized method was successfully applied to the analysis of phenolic acids and flavonoids in pigmented (red and black rice) and non-pigmented rice (brown rice) samples. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Analysis of Free Amino Acids in Different Extracts of Orthosiphon stamineus Leaves by High-Performance Liquid Chromatography Combined with Solid-Phase Extraction

    PubMed Central

    Shafaei, Armaghan; Halim, Nor Hidayah Ab; Zakaria, Norhidayah; Ismail, Zhari

    2017-01-01

    Background: Orthosiphon stamineus (OS) Benth is a medicinal plant and native in Southeast Asia. Previous studies have shown that OS leaves possess antioxidant, cytotoxic, diuretic, antihypertensive, and uricosuric effects. These beneficial effects have been attributed to the presence of primary and secondary metabolites such as polyphenols, amino acids, and flavonoids. Objective: To develop and validate an high-performance liquid chromatography (HPLC)-diode array detector (DAD) method combined with solid-phase extraction that involves precolumn derivatization with O-phthaladehyde for simultaneous analysis of free amino acids in OS leaves extracts. Materials and Methods: OS leaves were extracted with water (OS-W), ethanol (OS-E), methanol (OS-M), 50% ethanol (OS-EW), and 50% methanol (OS-MW). The extracts were treated by C18 cartridge before derivatization, resulting in great improvement of separation by Zorbox Eclipse XDB-C18 column. Results: The HPLC–DAD method was successfully developed and validated for analyzing the contents of free amino acids in OS extracts. The results showed that l-aspartic acid with 0.93 ± 0.01 nmol/mg was the major free amino acid in OS-W extract. However, in OS-E, OS-M, OS-EW, and OS-MW, l-glutamic acid with 3.53 ± 0.16, 2.17 ± 0.10, 4.01 ± 0.12, and 2.49 ± 0.12 nmol/mg, respectively, was the major free amino acid. Subsequently, l-serine, which was detected in OS-W, OS-E, and OS-M, was the minor free amino acid with 0.33 ± 0.02, 0.12 ± 0.01, and 0.06 ± 0.01 nmol/mg, respectively. However, l-threonine with 0.26 ± 0.02 and 0.19 ± 0.08 nmol/mL in OS-EW and OS-MW, respectively, had the lowest concentration compared with other amino acid components. Conclusion: All validation parameters of the developed method indicate that the method is reliable and efficient to simultaneously determine the free amino acids content for routine analysis of OS extracts. SUMMARY The HPLC-DAD method combined with solid phase extraction was successfully developed and validated for simultaneous determination and quantification of 17 free amino acids in Orthosiphon stamineus (OS) Benth extractsOS extracts were found to be rich in free amino acid contentL-aspartic acid was the major free amino acid in OS water extract while, in OS ethanol, methanol, 50% ethanol and 50% methanol extracts, L-glutamic acid was the major free amino acidL-serine was the minor free amino acid in OS water, ethanol and methanol extracts while, in OS 50% ethanol and 50% methanol extracts, L-threonine had the lowest concentration compared to other amino acid components. Abbreviations used: HPLC-DAD: High-Performance Liquid Chromatography with Diode-Array Detection, OS: Orthosiphon stamineus, OS-W: Orthosiphon stamineus water extract, OS-E: Orthosiphon stamineus ethanol extract, OS-M: Orthosiphon stamineus methanol extract, OS-EW: Orthosiphon stamineus 50% ethanol extract, OS-MW: Orthosiphon stamineus 50% methanol extract, OPA: O-phthaladehyde, SPE: Solid Phase Extraction, UV: Ultraviolet, LOD: Limit of Detection, LOQ: Limit of Quantification, RSD: Relative Standard Deviation. PMID:29142388

  19. Development and validation of a matrix solid-phase dispersion method to determine acrylamide in coffee and coffee substitutes.

    PubMed

    Soares, Cristina M Dias; Alves, Rita C; Casal, Susana; Oliveira, M Beatriz P P; Fernandes, José Oliveira

    2010-04-01

    The present study describes the development and validation of a new method based on a matrix solid-phase dispersion (MSPD) sample preparation procedure followed by GC-MS for determination of acrylamide levels in coffee (ground coffee and brewed coffee) and coffee substitute samples. Samples were dispersed in C(18) sorbent and the mixture was further packed into a preconditioned custom-made ISOLUTE bilayered SPE column (C(18)/Multimode; 1 g + 1 g). Acrylamide was subsequently eluted with water, and then derivatized with bromine and quantified by GC-MS in SIM mode. The MSPD/GC-MS method presented a LOD of 5 microg/kg and a LOQ of 10 microg/kg. Intra and interday precisions ranged from 2% to 4% and 4% to 10%, respectively. To evaluate the performance of the method, 11 samples of ground and brewed coffee and coffee substitutes were simultaneously analyzed by the developed method and also by a previously validated method based in a liquid-extraction (LE) procedure, and the results were compared showing a high correlation between them.

  20. Comparative study of different clean-up techniques for the determination of λ-cyhalothrin and cypermethrin in palm oil matrices by gas chromatography with electron capture detection.

    PubMed

    Muhamad, Halimah; Zainudin, Badrul Hisyam; Abu Bakar, Nor Kartini

    2012-10-15

    Solid phase extraction (SPE) and dispersive solid-phase extraction (d-SPE) were compared and evaluated for the determination of λ-cyhalothrin and cypermethrin in palm oil matrices by gas chromatography with an electron capture detector (GC-ECD). Several SPE sorbents such as graphitised carbon black (GCB), primary secondary amine (PSA), C(18), silica, and florisil were tested in order to minimise fat residues. The results show that mixed sorbents using GCB and PSA obtained cleaner extracts than a single GCB and PSA sorbents. The average recoveries obtained for each pesticide ranged between 81% and 114% at five fortification levels with the relative standard deviation of less than 7% in all cases. The limits of detection for these pesticides were ranged between 0.025 and 0.05 μg/g. The proposed method was applied successfully for the residue determination of both λ-cyhalothrin and cypermethrin in crude palm oil samples obtained from local mills throughout Malaysia. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Application of mixed-mode, solid-phase extraction in environmental and clinical chemistry. Combining hydrogen-bonding, cation-exchange and Van der Waals interactions

    USGS Publications Warehouse

    Mills, M.S.; Thurman, E.M.; Pedersen, M.J.

    1993-01-01

    Silica- and styrene-divinylbenzene-based mixed-mode resins that contain C8, C18 and sulphonated cation-exchange groups were compared for their efficiency in isolation of neutral triazine compounds from water and of the basic drug, benzoylecgonine, from urine. The triazine compounds were isolated by a combination of Van der Waals and hydrogen-bonding interactions, and benzoylecgonine was isolated by Van der Waals interactions and cation exchange. All analytes were eluted with a polar organic solvent contaning 2% ammonium hydroxide. Larger recoveries (95%) were achieved on copolymerized mixed-mode resins where C18 and sulfonic acid are in closer proximity than on 'blended' mixed-mode resins (60-70% recovery).

  2. A core-shell column approach to a comprehensive high-performance liquid chromatography phenolic analysis of Vitis vinifera L. and interspecific hybrid grape juices, wines, and other matrices following either solid phase extraction or direct injection.

    PubMed

    Manns, David C; Mansfield, Anna Katharine

    2012-08-17

    Four high-throughput reverse-phase chromatographic protocols utilizing two different core-shell column chemistries have been developed to analyze the phenolic profiles of complex matrices, specifically targeting juices and wines produced from interspecific hybrid grape cultivars. Following pre-fractionation via solid-phase extraction or direct injection, individual protocols were designed to resolve, identify and quantify specific chemical classes of compounds including non-anthocyanin monomeric phenolics, condensed tannins following acid hydrolysis, and anthocyanins. Detection levels ranging from 1.2 ppb to 27.5 ppb, analyte %RSDs ranging from 0.04 to 0.38, and linear ranges of quantitation approaching five orders of magnitude were achieved using conventional HPLC instrumentation. Using C(18) column chemistry, the non-anthocyanin monomeric protocol effectively separated a set of 16 relevant phenolic compounds comprised flavan-3-ols, hydroxycinnamic acids, and flavonols in under 14 min. The same column was used to develop a 15-min protocol for hydrolyzed condensed tannin analysis. Two anthocyanin protocols are presented, one utilizing the same C(18) column, best suited for anthocyanidin and monoglucoside analysis, the other utilizing a pentafluorophenyl chemistry optimized to effectively separate complex mixtures of coexisting mono- and diglucoside anthocyanins. These protocols and column chemistries have been used initially to explore a wide variety of complex phenolic matrices, including red and white juices and wines produced from Vitis vinifera and interspecific hybrid grape cultivars, juices, teas, and plant extracts. Each protocol displayed robust matrix responses as written, yet are flexible enough to be easily modified to suit specifically tailored analytical requirements. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Comparison of different mesoporous silicas for off-line solid phase extraction of 17β-estradiol from waters and its determination by HPLC-DAD.

    PubMed

    Gañán, Judith; Pérez-Quintanilla, Damián; Morante-Zarcero, Sonia; Sierra, Isabel

    2013-09-15

    Functionalized (SBA-C₁₈ and SM-C₁₈) and non-functionalized (SBA-15 and SM) mesoporous silicas were then examined as sorbents for solid-phase extraction of 17β-estradiol in aqueous media. Experiments were run in order to test critical factors affecting the procedure extraction efficiency, including the type of sorbent, the analyte concentration, the solvent and volume used for elution and the sample volume. Among the prepared materials, SBA-C₁₈ had the highest adsorption affinity towards 17β-estradiol and under optimized conditions (200mg of sorbent, 150 mL of water sample, elution with 3 × 2 mL of methanol) this sorbent proved good extraction capacity and elution efficiency for this hormone from aqueous media (recovery near 100%). To evaluate the analytical applicability of the proposed method, it was applied to the determination of 17β-estradiol in drinking water by high performance liquid chromatography with a photodiode array detector. Calibration curves were shown to be linear between 1.25 and 100 mg L(-1)with correlation coefficients ≥0.999 (n=5) for 17β-estradiol. The instrumental detection and quantitation limits calculated were 0.38 and 1.25 mg L(-1), respectively. The relative standard deviation obtained values were ≤3% and the mean recoveries obtained were of 82%. The results suggest that SBA-C18 is a promising material for the off-line solid phase extraction of 17β-estradiol from waters. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Liquid chromatographic-diode-array detection multiresidue determination of rice herbicides in drinking and paddy-field water.

    PubMed

    Roehrs, Rafael; Zanella, Renato; Pizzuti, Ionara; Adaime, Martha B; Pareja, Lucía; Niell, Silvina; Cesio, María V; Heinzen, Horacio

    2009-01-01

    A sensitive, rapid, and simple multiresidue method for the simultaneous determination of six postemergence herbicides currently used in rice cultivation--metsulfuron methyl, bensulfuron methyl, pyrazosulfuron ethyl, bentazone, bispyribac sodium, and cyhalofop butyl--in drinking and paddy-field water is presented. Water samples were extracted with solid-phase extraction cartridges. Final determination was made by LC with diode-array detection. The extraction efficiencies of C18 and HLB cartridges were compared. The average recovery obtained for these compounds for the lowest spiked level (0.1 microg/L) varied from 70 to 122% for C18 and 75-119% for HLB, with RSDs of 11 and 8.3%, respectively. The method had good linearity, and the lower detection limit for the pesticides studied varied from 0.03 to 0.04 microg/L. The proposed method was also tested in paddy-field water, with recovery studies giving good results with low RSDs at 1.0 microg/L.

  5. An HPLC method for determination of azadirachtin residues in bovine muscle.

    PubMed

    Gai, María Nella; Álvarez, Christian; Venegas, Raúl; Morales, Javier

    2011-04-01

    A high-performance liquid chromatography (HPLC) method for the determination of azadirachtin (A and B) residues in bovine muscle has been developed. Azadirachtin is a neutral triterpene and chemotherapeutic agent effective in controlling some pest flies in horses, stables, horns and fruit. The actual HPLC method uses an isocratic elution and UV detection. Liquid-liquid extraction and solid-phase purification was used for the clean-up of the biological matrix. The chromatographic determination of these components is achieved using a C18 analytical column with water-acetonitrile mixture (27.5:72.5, v/v) as mobile phase, 1 mL/min as flow rate, 45 °C column temperature and UV detector at 215 nm. The azadirachtin peaks are well resolved and free of interference from matrix components. The extraction and analytical method developed in this work allows the quantitation of azadirachtin with precision and accuracy, establishing a lower limit of quantitation of azadirachtin, extracted from the biological matrix.

  6. Purification and characterization of antimicrobial peptides from fish isolate Carnobacterium maltaromaticum C2: Carnobacteriocin X and carnolysins A1 and A2.

    PubMed

    Tulini, Fabricio L; Lohans, Christopher T; Bordon, Karla C F; Zheng, Jing; Arantes, Eliane C; Vederas, John C; De Martinis, Elaine C P

    2014-03-03

    Carnobacterium maltaromaticum C2, isolated from Brazilian smoked fish (Surubim, Pseudoplatystoma sp.), was found to exert antimicrobial activity against Listeria monocytogenes, an important foodborne pathogen. In this study, the bacteriocins produced by C. maltaromaticum C2 were purified via an extraction with XAD-16 resin, a C18 solid phase extraction, followed by reversed-phase fast protein liquid chromatography. The purified active fractions were characterized using tandem mass spectrometry, permitting the identification of multiple bacteriocins. Carnobacteriocins BM1, B1, and a variant of carnobacteriocin B2 were all found, providing much of the antilisterial activity. Additionally, we herein report the first isolation of the previously predicted antimicrobial peptide carnobacteriocin X. Moreover, C. maltaromaticum C2 produces a novel two-component lantibiotic, termed carnolysin, homologous to enterococcal cytolysin. This lantibiotic is antimicrobially inactive when tested against the non-bacteriocinogenic strain C. maltaromaticum A9b-, likely requiring an additional proteolytic cleavage to reach maturity. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Boron nitride as desalting material in combination with phosphopeptide enrichment in shotgun proteomics.

    PubMed

    Furuhashi, Takeshi; Nukarinen, Ella; Ota, Shigenori; Weckwerth, Wolfram

    2014-05-01

    Hydrophilic peptides in shotgun proteomics have been shown to be problematic in conventional chromatography. Typically, C18 solid phase extraction or peptide traps are used for desalting the sample prior to mass spectrometry analysis, but the capacity to retain hydrophilic peptides is not very high, causing a bias toward more hydrophobic peptides. This is particularly problematic in phosphoproteomic studies. We tested the compatibility of commercially available boron nitride as a novel material for peptide desalting. Boron nitride can be used to recover a wide range of peptides with different physicochemical properties comparable to combined C18 and graphite carbon material. Copyright © 2014. Published by Elsevier Inc.

  8. A novel approach to the simultaneous extraction and non-targeted analysis of the small molecules metabolome and lipidome using 96-well solid phase extraction plates with column-switching technology.

    PubMed

    Li, Yubo; Zhang, Zhenzhu; Liu, Xinyu; Li, Aizhu; Hou, Zhiguo; Wang, Yuming; Zhang, Yanjun

    2015-08-28

    This study combines solid phase extraction (SPE) using 96-well plates with column-switching technology to construct a rapid and high-throughput method for the simultaneous extraction and non-targeted analysis of small molecules metabolome and lipidome based on ultra-performance liquid chromatography quadrupole time-of-flight mass spectrometry. This study first investigated the columns and analytical conditions for small molecules metabolome and lipidome, separated by an HSS T3 and BEH C18 columns, respectively. Next, the loading capacity and actuation duration of SPE were further optimized. Subsequently, SPE and column switching were used together to rapidly and comprehensively analyze the biological samples. The experimental results showed that the new analytical procedure had good precision and maintained sample stability (RSD<15%). The method was then satisfactorily applied to more widely analyze the small molecules metabolome and lipidome to test the throughput. The resulting method represents a new analytical approach for biological samples, and a highly useful tool for researches in metabolomics and lipidomics. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Development and Validation of a Liquid Chromatography-Tandem Mass Spectrometry Method Coupled with Dispersive Solid-Phase Extraction for Simultaneous Quantification of Eight Paralytic Shellfish Poisoning Toxins in Shellfish.

    PubMed

    Yang, Xianli; Zhou, Lei; Tan, Yanglan; Shi, Xizhi; Zhao, Zhiyong; Nie, Dongxia; Zhou, Changyan; Liu, Hong

    2017-06-29

    In this study, a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed for simultaneous determination of eight paralytic shellfish poisoning (PSP) toxins, including saxitoxin (STX), neosaxitoxin (NEO), gonyautoxins (GTX1-4) and the N -sulfo carbamoyl toxins C1 and C2, in sea shellfish. The samples were extracted by acetonitrile/water (80:20, v / v ) with 0.1% formic and purified by dispersive solid-phase extraction (dSPE) with C18 silica and acidic alumina. Qualitative and quantitative detection for the target toxins were conducted under the multiple reaction monitoring (MRM) mode by using the positive electrospray ionization (ESI) mode after chromatographic separation on a TSK-gel Amide-80 HILIC column with water and acetonitrile. Matrix-matched calibration was used to compensate for matrix effects. The established method was further validated by determining the linearity ( R ² ≥ 0.9900), average recovery (81.52-116.50%), sensitivity (limits of detection (LODs): 0.33-5.52 μg·kg -1 ; limits of quantitation (LOQs): 1.32-11.29 μg·kg -1 ) and precision (relative standard deviation (RSD) ≤ 19.10%). The application of this proposed approach to thirty shellfish samples proved its desirable performance and sufficient capability for simultaneous determination of multiclass PSP toxins in sea foods.

  10. Application of pseudo-template molecularly imprinted polymers by atom transfer radical polymerization to the solid-phase extraction of pyrethroids.

    PubMed

    Zhang, Ming; He, Juan; Shen, Yanzheng; He, Weiye; Li, Yuanyuan; Zhao, Dongxin; Zhang, Shusheng

    2018-02-01

    A polymer-based adsorption medium with molecular recognition ability for homologs of pyrethroids was prepared by atom transfer radical polymer iration using a fragment imprinting technique. Phenyl ether-biphenyl eutectic was utilized as a pseudo-template molecule, and the adsorption medium prepared was evaluated by solid-phase extraction and gas chromatography. Selectivity of the medium for pyrethroids was evaluated using it as solid phase extraction packing by Gas Chromatography. The results demonstrated that the absorption amount of bifenthrin, fenpropathrin, permethrin, cypermethrin, fenvalerate, Dursban and pentachloronitrobenzene for molecularly imprinted polymers were 2.32, 2.12, 2.18, 2.20, 2.30, 1.30 and 1.40mgg -1 , respectively, while the non-imprinted polymers were 1.20, 1.13, 1.25, 1.05, 1.20, 1.23 and 1.32mgg -1 , respectively. The rebinding test based on the molecularly imprinted solid phase extraction column technique showed the recoveries of honey sample spiked with seven insecticides within 88.5-106.2%, with relative standard deviations of 2.38-5.63%. Finally, the method was successfully applied to the analysis of pyrethroids in a honey sample. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. An Effective Method to Detect Volatile Intermediates Generated in the Bioconversion of Coal to Methane by Gas Chromatography-Mass Spectrometry after In-Situ Extraction Using Headspace Solid-Phase Micro-Extraction under Strict Anaerobic Conditions.

    PubMed

    Liu, Jianmin; Wang, Baoyu; Tai, Chao; Wu, Li; Zhao, Han; Guan, Jiadong; Chen, Linyong

    2016-01-01

    Bioconversion of coal to methane has gained increased attention in recent decades because of its economic and environmental advantages. However, the mechanism of this process is difficult to study in depth, partly because of difficulties associated with the analysis of intermediates generated in coal bioconversion. In this investigation, we report on an effective method to analyze volatile intermediates generated in the bioconversion of coal under strict anaerobic conditions. We conduct in-situ extraction of intermediates using headspace solid-phase micro-extraction followed by detection by gas chromatography-mass spectrometry. Bioconversion simulation equipment was modified and combined with a solid-phase micro-extraction device. In-situ extraction could be achieved by using the combined units, to avoid a breakdown in anaerobic conditions and to maintain the experiment continuity. More than 30 intermediates were identified qualitatively in the conversion process, and the variation in trends of some typical intermediates has been discussed. Volatile organic acids (C2-C7) were chosen for a quantitative study of the intermediates because of their importance during coal bioconversion to methane. Fiber coating, extraction time, and solution acidity were optimized in the solid-phase micro-extraction procedure. The pressure was enhanced during the bioconversion process to investigate the influence of headspace pressure on analyte extraction. The detection limits of the method ranged from 0.0006 to 0.02 mmol/L for the volatile organic acids and the relative standard deviations were between 4.6% and 11.5%. The volatile organic acids (C2-C7) generated in the bioconversion process were 0.01-1.15 mmol/L with a recovery range from 80% to 105%. The developed method is useful for further in-depth research on the bioconversion of coal to methane.

  12. An Effective Method to Detect Volatile Intermediates Generated in the Bioconversion of Coal to Methane by Gas Chromatography-Mass Spectrometry after In-Situ Extraction Using Headspace Solid-Phase Micro-Extraction under Strict Anaerobic Conditions

    PubMed Central

    Liu, Jianmin; Wang, Baoyu; Tai, Chao; Wu, Li; Zhao, Han; Guan, Jiadong; Chen, Linyong

    2016-01-01

    Bioconversion of coal to methane has gained increased attention in recent decades because of its economic and environmental advantages. However, the mechanism of this process is difficult to study in depth, partly because of difficulties associated with the analysis of intermediates generated in coal bioconversion. In this investigation, we report on an effective method to analyze volatile intermediates generated in the bioconversion of coal under strict anaerobic conditions. We conduct in-situ extraction of intermediates using headspace solid-phase micro-extraction followed by detection by gas chromatography-mass spectrometry. Bioconversion simulation equipment was modified and combined with a solid-phase micro-extraction device. In-situ extraction could be achieved by using the combined units, to avoid a breakdown in anaerobic conditions and to maintain the experiment continuity. More than 30 intermediates were identified qualitatively in the conversion process, and the variation in trends of some typical intermediates has been discussed. Volatile organic acids (C2–C7) were chosen for a quantitative study of the intermediates because of their importance during coal bioconversion to methane. Fiber coating, extraction time, and solution acidity were optimized in the solid-phase micro-extraction procedure. The pressure was enhanced during the bioconversion process to investigate the influence of headspace pressure on analyte extraction. The detection limits of the method ranged from 0.0006 to 0.02 mmol/L for the volatile organic acids and the relative standard deviations were between 4.6% and 11.5%. The volatile organic acids (C2–C7) generated in the bioconversion process were 0.01–1.15 mmol/L with a recovery range from 80% to 105%. The developed method is useful for further in-depth research on the bioconversion of coal to methane. PMID:27695055

  13. Long-term TNT sorption and bound residue formation in soil

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hundal, L.S.; Shea, P.J.; Comfort, S.D.

    1997-05-01

    Soils surrounding former munitions production facilities are highly contaminated with 2,4,6-trinitrotoluene (TNT). Long-term availability and fate of TNT and its transformation products must be understood to predict environmental impact and develop appropriate remediation strategies. Sorption and transport in surface soil containing solid-phase TNT are particularly critical, since nonlinear sorption isotherms indicate greater TNT availability for transport at high concentrations. Our objectives were to determine long-term sorption and bound residue formation in surface and subsurface Sharpsburg soil (Typic Argiudoll). Prolonged equilibration of {sup 14}C-TNT with the soil revealed a gradual increase in amount sorbed and formation of unextractable (bound) {sup 14}Cmore » residues. The presence of solid-phase TNT did not initially affect the amount of {sup 14}C sorbed during a 168-d equilibration. After 168d, 93% of the added {sup 14}C was sorbed by uncontaminated soil, while 79% was sorbed by soil containing solid-phase TNT. In the absence of solid phase, pools of readily available (extractable with 3 mM CaCl{sub 2}) and potentially available (CH{sub 3}CN-extractable) sorbed TNT decreased rapidly with time and coincided with increased {sup 14}C in soil organic matter. More {sup 14}C was found in fulvic acid than in the humic acid fraction when no solid-phase TNT was present. After sequential extractions, including strong alkali and acid, 32 to 40% of the sorbed {sup 14}C was irreversibly bound (unextractable) in Sharpsburg surface and subsurface soil. Results provide strong evidence for humification of TNT in soil. This process may represent a significant route for detoxification in the soil-water environment. 58 refs., 6 figs., 3 tabs.« less

  14. Methods of analysis by the U.S. Geological Survey Organic Geochemistry Research Group : determination of selected herbicides and their degradation products in water using solid-phase extraction and gas chromatography/mass spectrometry

    USGS Publications Warehouse

    Kish, J.L.; Thurman, E.M.; Scribner, E.A.; Zimmerman, L.R.

    2000-01-01

    A method for the extraction and analysis of eight herbicides and five degradation products using solid-phase extraction from natural water samples followed by gas chromatography/mass spectrometry is presented in this report. This method was developed for dimethenamid; flufenacet; fluometuron and its degradation products, demethylfluometuron (DMFM), 3-(trifluromethyl)phenylurea (TFMPU), 3-(trifluromethyl)-aniline (TFMA); molinate; norflurazon and its degradation product, demethylnorflurazon; pendamethalin; the degradation product of prometryn, deisopropylprometryn; propanil; and trifluralin. The eight herbicides are used primarily in the southern United States where cotton, rice, and soybeans are produced. The exceptions are dimethenamid and flufenacet, which are used on corn in the Midwest. Water samples received by the U.S. Geological Survey's Organic Geochemistry Research Group in Lawrence, Kansas, are filtered to remove suspended particulate matter and then passed through disposable solid-phase extraction columns containing octadecyl-bonded porous silica (C-18) to extract the compounds. The herbicides and their degradation products are removed from the column by ethyl acetate elution. The eluate is evaporated under nitrogen, and components then are separated, identified, and quantified by injecting an aliquot of the concentrated extract into a high-resolution, fused-silica capillary column of a gas chromatograph/mass spectrometer under selected-ion mode. Method detection limits ranged from 0.02 to 0.05 ?g/L for all compounds with the exception of TFMPU, which has a method detection limit of 0.32 ?g/L. The mean absolute recovery is 107 percent. This method for the determination of herbicides and their degradation products is valuable for acquiring information about water quality and compound fate and transport in water.

  15. Determination of Five Major 8-Prenylflavones in Leaves of Epimedium by Solid-Phase Extraction Coupled with Capillary Electrophoresis

    PubMed Central

    Xie, Juan-ping; Xiang, Ji-ming; Zhu, Zhong-liang

    2016-01-01

    A simple, accurate and reproducible method which is based on the capillary electrophoresis, coupled with solid-phase extraction, has been developed for simultaneous determination of multiple 8-prenylflavones from Chinese Herba Epimedii. In this study, the author has mainly illustrated the experimental process and research results of five major components including epimedin C, icariin, diphylloside A, epimedoside A and icarisoside A that have been extracted and identified from Herba Epimedii for the first time. Experimental conditions have been optimized to achieve the best separation efficiency for the following factors: the buffer pH, buffer concentration and applied voltage. The experiment can be conducted through two separable stages: the first stage is to obtain the crude extracts through the solid-phase extraction; and the second stage is to further separate five major components by using the capillary electrophoresis. The separation of the five components and the analysis of the experiment are relatively fast and can be completed within 20 min. The concentration ranges of the construction of standard curves of five major 8-prenylflavones are 32.0–395.0, 23.4–292.0, 42.1–526.0, 18.8–233.5 and 29.7–371.0 µg mL−1 respectively, which have showed acceptable linearity with a correlation coefficient, r ≥ 0.999. The coefficient varies within 2.0% for both intra- and inter-days tests. The recoveries of five components range from 92.3 to 104.1%. The relative standard deviations of recoveries of five components range from 1.2 and 2.8%. This new method will facilitate the extraction and expedite the determination of medical components from Herba Epimedii. PMID:26865656

  16. Novel surface-active oligofructose fatty acid mono-esters by enzymatic esterification.

    PubMed

    van Kempen, Silvia E H J; Boeriu, Carmen G; Schols, Henk A; de Waard, Pieter; van der Linden, Erik; Sagis, Leonard M C

    2013-06-01

    This article describes the synthesis of a series of oligofructose monoesters with fatty acids of different chain length (C8, C12, C16 and C18) to obtain food-grade surfactants with a range of amphiphilicity. Reactions were performed in a mixture of DMSO/Bu(t)OH (10/90 v/v) at 60°C and catalysed by immobilised Candida antarctica lipase B. MALDI-TOF-MS analysis showed that the crude reaction products were mixtures of unmodified oligofructose and mostly mono-esters. The conversion into mono-esters increased with the length of the fatty acid chain, reflecting the specificity of the lipase towards more lipophilic substrates. Reverse phase solid phase extraction was used to fractionate the products, which lead to sufficient purity (>93%) of the fatty acid esters for functionality testing. It was shown that derivatives of longer (C16 and C18) fatty acids were more efficient in lowering surface tension and gave a much higher dilatational modulus than derivatives of the shorter (C8 and C12) fatty acids. Copyright © 2012 Elsevier Ltd. All rights reserved.

  17. Ionic liquids intercalated in montmorillonite as the sorptive phase for the extraction of low-polarity organic compounds from water by rotating-disk sorptive extraction.

    PubMed

    Fiscal-Ladino, Jhon A; Obando-Ceballos, Mónica; Rosero-Moreano, Milton; Montaño, Diego F; Cardona, Wilson; Giraldo, Luis F; Richter, Pablo

    2017-02-08

    Montmorillonite (MMT) clays were modified by the intercalation into their galleries of ionic liquids (IL) based on imidazolium quaternary ammonium salts. This new eco-materials exhibited good features for use as a sorptive phase in the extraction of low-polarity analytes from aqueous samples. Spectroscopic analyses of the modified clays were conducted and revealed an increase in the basal spacing and a shifting of the reflection plane towards lower values as a consequence of the effective intercalation of organic cations into the MMT structure. The novel sorbent developed herein was assayed as the sorptive phase in rotating-disk sorptive extraction (RDSE), using polychlorinated biphenyls (PCBs), representative of low-polarity pollutants, as model analytes. The final determination was made by gas chromatography with electron capture detection. Among the synthetized sorptive phases, the selected system for analytical purposes consisted of MMT modified with the 1-hexadecyl-3-methylimidazolium bromide (HDMIM-Br) IL. Satisfactory analytical features were achieved using a sample volume of 5 mL: the relative recoveries from a wastewater sample were higher than 80%, the detection limits were between 3 ng L -1 and 43 ng L -1 , the precision (within-run precision) expressed as the relative standard deviation ranged from 2% to 24%, and the enrichment factors ranged between 18 and 28. Using RDSE, the extraction efficiency achieved for the selected MMT-HDMIM-Br phase was compared with other commercial solid phases/supports, such as polypropylene, polypropylene with 1-octanol (as a supported liquid membrane), octadecyl (C18) and octyl (C8), and showed the highest response for all the studied analytes. Under the optimized extraction conditions, this new device was applied in the analysis of the influent of a wastewater treatment plant in Santiago (Chile), demonstrating its applicability through the good recoveries and precision achieved with real samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. A simple and selective method for determination of phthalate biomarkers in vegetable samples by high pressure liquid chromatography-electrospray ionization-tandem mass spectrometry.

    PubMed

    Zhou, Xi; Cui, Kunyan; Zeng, Feng; Li, Shoucong; Zeng, Zunxiang

    2016-06-01

    In the present study, solid-phase extraction cartridges including silica reversed-phase Isolute C18, polymeric reversed-phase Oasis HLB and mixed-mode anion-exchange Oasis MAX, and liquid-liquid extractions with ethyl acetate, n-hexane, dichloromethane and its mixtures were compared for clean-up of phthalate monoesters from vegetable samples. Best recoveries and minimised matrix effects were achieved using ethyl acetate/n-hexane liquid-liquid extraction for these target compounds. A simple and selective method, based on sample preparation by ultrasonic extraction and liquid-liquid extraction clean-up, for the determination of phthalate monoesters in vegetable samples by liquid chromatography/electrospray ionisation-tandem mass spectrometry was developed. The method detection limits for phthalate monoesters ranged from 0.013 to 0.120 ng g(-1). Good linearity (r(2)>0.991) between MQLs and 1000× MQLs was achieved. The intra- and inter-day relative standard deviation values were less than 11.8%. The method was successfully used to determine phthalate monoester metabolites in the vegetable samples. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Extractant composition including crown ether and calixarene extractants

    DOEpatents

    Meikrantz, David H.; Todd, Terry A.; Riddle, Catherine L.; Law, Jack D.; Peterman, Dean R.; Mincher, Bruce J.; McGrath, Christopher A.; Baker, John D.

    2009-04-28

    An extractant composition comprising a mixed extractant solvent consisting of calix[4] arene-bis-(tert-octylbenzo)-crown-6 ("BOBCalixC6"), 4',4',(5')-di-(t-butyldicyclo-hexano)-18-crown-6 ("DtBu18C6"), and at least one modifier dissolved in a diluent. The DtBu18C6 may be present at from approximately 0.01M to approximately 0.4M, such as at from approximately 0.086 M to approximately 0.108 M. The modifier may be 1-(2,2,3,3-tetrafluoropropoxy)-3-(4-sec-butylphenoxy)-2-propanol ("Cs-7SB") and may be present at from approximately 0.01M to approximately 0.8M. In one embodiment, the mixed extractant solvent includes approximately 0.15M DtBu18C6, approximately 0.007M BOBCalixC6, and approximately 0.75M Cs-7SB modifier dissolved in an isoparaffinic hydrocarbon diluent. The extractant composition further comprises an aqueous phase. The mixed extractant solvent may be used to remove cesium and strontium from the aqueous phase.

  20. Determination of perfluorinated chemicals in food and drinking water using high-flow solid-phase extraction and ultra-high performance liquid chromatography/tandem mass spectrometry.

    PubMed

    Chang, Ying-Chia; Chen, Wen-Ling; Bai, Fang-Yu; Chen, Pau-Chung; Wang, Gen-Shuh; Chen, Chia-Yang

    2012-01-01

    For this study, we developed methods of determining ten perfluorinated chemicals in drinking water, milk, fish, beef, and pig liver using high-flow automated solid-phase extraction (SPE) and ultra-high performance liquid chromatography/tandem mass spectrometry. The analytes were separated on a core-shell Kinetex C18 column. The mobile phase was composed of methanol and 10-mM N-methylmorpholine. Milk was digested with 0.5 N potassium hydroxide in Milli-Q water, and was extracted with an Atlantic HLB disk to perform automated SPE at a flow rate ranged from 70 to 86 mL/min. Drinking water was directly extracted by the SPE. Solid food samples were digested in alkaline methanol and their supernatants were diluted and also processed by SPE. The disks were washed with 40% methanol/60% water and then eluted with 0.1% ammonium hydroxide in methanol. Suppression of signal intensity of most analytes by matrixes was lower than 50%; it was generally lower in fish and drinking water but higher in liver. Most quantitative biases and relative standard deviations were lower than 15%. The limits of detection for most analytes were sub-nanograms per liter for drinking water and sub-nanograms per gram for solid food samples. This method greatly shortened the time and labor needed for digestion, SPE, and liquid chromatography. This method has been applied to analyze 14 types of food samples. Perfluorooctanoic acid was found to be the highest among the analytes (median at 3.2-64 ng/g wet weight), followed by perfluorodecanoic acid (0.7-25 ng/g) and perfluorododecanoic acid (0.6-15 ng/g).

  1. A fully automated method for simultaneous determination of aflatoxins and ochratoxin A in dried fruits by pressurized liquid extraction and online solid-phase extraction cleanup coupled to ultra-high-pressure liquid chromatography-tandem mass spectrometry.

    PubMed

    Campone, Luca; Piccinelli, Anna Lisa; Celano, Rita; Russo, Mariateresa; Valdés, Alberto; Ibáñez, Clara; Rastrelli, Luca

    2015-04-01

    According to current demands and future perspectives in food safety, this study reports a fast and fully automated analytical method for the simultaneous analysis of the mycotoxins with high toxicity and wide spread, aflatoxins (AFs) and ochratoxin A (OTA) in dried fruits, a high-risk foodstuff. The method is based on pressurized liquid extraction (PLE), with aqueous methanol (30%) at 110 °C, of the slurried dried fruit and online solid-phase extraction (online SPE) cleanup of the PLE extracts with a C18 cartridge. The purified sample was directly analysed by ultra-high-pressure liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) for sensitive and selective determination of AFs and OTA. The proposed analytical procedure was validated for different dried fruits (vine fruit, fig and apricot), providing method detection and quantification limits much lower than the AFs and OTA maximum levels imposed by EU regulation in dried fruit for direct human consumption. Also, recoveries (83-103%) and repeatability (RSD < 8, n = 3) meet the performance criteria required by EU regulation for the determination of the levels of mycotoxins in foodstuffs. The main advantage of the proposed method is full automation of the whole analytical procedure that reduces the time and cost of the analysis, sample manipulation and solvent consumption, enabling high-throughput analysis and highly accurate and precise results.

  2. Headspace Solid-Phase Microextraction and Ultrasonic Extraction with the Solvent Sequences in Chemical Profiling of Allium ursinum L. Honey.

    PubMed

    Jerković, Igor; Kuś, Piotr M

    2017-11-06

    A volatile profile of ramson (wild garlic, Allium ursinum L.) honey was investigated by headspace solid-phase microextraction (HS-SPME) and ultrasonic solvent extraction (USE) followed by gas chromatography and mass spectrometry (GC-FID/GC-MS) analyses. The headspace was dominated by linalool derivatives: cis - and trans -linalool oxides (25.3%; 9.2%), hotrienol (12.7%), and linalool (5.8%). Besides direct extraction with dichloromethane and pentane/diethyl ether mixture (1:2, v / v ), two solvent sequences (I: pentane → diethyl ether; II: pentane → pentane/diethyl ether (1:2, v / v ) → dichloromethane) were applied. Striking differences were noted among the obtained chemical profiles. The extracts with diethyl ether contained hydroquinone (25.8-36.8%) and 4-hydroxybenzoic acid (11.6-16.6%) as the major compounds, while ( E )-4-(r-1',t-2',c-4'-trihydroxy-2',6',6'-trimethylcyclohexyl)but-3-en-2-one predominated in dichloromethane extracts (18.3-49.1%). Therefore, combination of different solvents was crucial for the comprehensive investigation of volatile organic compounds in this honey type. This particular magastigmane was previously reported only in thymus honey and hydroquinone in vipers bugloss honey, while a combination of the mentioned predominant compounds is unique for A. ursinum honey.

  3. Profiling of phytohormones and their major metabolites in rice using binary solid-phase extraction and liquid chromatography-triple quadrupole mass spectrometry.

    PubMed

    Cao, Zhao-Yun; Sun, Li-Hua; Mou, Ren-Xiang; Zhang, Lin-Ping; Lin, Xiao-Yan; Zhu, Zhi-Wei; Chen, Ming-Xue

    2016-06-17

    A high-throughput method was developed using liquid chromatography-triple quadrupole mass spectrometry (LC-MS/MS) for the profiling and quantification of 43 phytohormones and their major metabolites, including auxins, abscisic acid, jasmonic acid, salicylic acid, cytokinins and gibberellins in a single sample extract. Considerable matrix effects (MEs) were observed (with most ME values in the range of 29%-84%, but maximum MEs of more than 115%, even up to 206%, existed) in sample extracts for most of the compounds studied. The application of the proposed binary solid-phase extraction using polymer anion and polymer cation exchange resins, was performed to purify 25 acidic and 18 alkaline phytohormones and their major metabolites prior to the LC-MS/MS analysis, which markedly reduced the MEs to acceptable levels, with ME values in the range of ±15%. Moreover, all of the isomers of cytokinins and their metabolites were fully separated on a sub-2μm particle C18 reverse-phase column with the optimized mobile phase consisting of methanol and 5mM ammonium formate. The method showed good linearity for all 43 analytes with regression coefficients (R(2))>0.991. Limits of detection ranged from 0.19 to 7.57 fmol for auxin, gibberellins, abscisic acid and their metabolites, 29.7 fmol for jasmonic acid, 18.1 fmol for salicylic acid, and from 0.03 to 0.31 fmol for cytokinins and their metabolites. The mean recoveries for all of the analytes were from 70.7 to 118.5%, and the inter-day precisions (n=6) were less than 18.7%, with intra-day precisions (n=6) within 25.4%. Finally, 20 compounds were successfully quantified in rice sample profiles using the proposed method, which will greatly facilitate the understanding of hormone-related regulatory networks that influence rice growth and development. To our knowledge, there are limited reports that measure this level of phytohormone species in rice samples using a single analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Application of the powder of porous titanium carbide ceramics to a reusable adsorbent for environmental pollutants.

    PubMed

    Moriwaki, Hiroshi; Kitajima, Shiori; Shirai, Koji; Kiguchi, Kenji; Yamada, Osamu

    2011-01-30

    The aim of this study is to investigate the utilization of the powder of porous titanium carbide (TiC) ceramics as a novel adsorbent or a material for solid-phase extraction (SPE). The adsorption and elution of inorganic and organic pollutants, Pb(II), 2,4,6-trichlorophenol (TCP), perfluorooctane sulfonate (PFOS), and perfluorooctanoic acid (PFOA), to the material were evaluated. The cartridge packed with TiC ceramics powder was used for the extraction test of pollutants. The solution containing pollutants at 1.0 μg mL(-1) was passed through the TiC cartridge, and the substances were almost quantitatively removed. Furthermore, the pollutants retained in the cartridge were eluted with 3N HCl for Pb(II) and with methanol for organic pollutants. The recoveries of pollutants were over 80%. In addition, we used the TiC cartridge for the solid-phase extraction of water samples (500 mL each of the distilled water and the river water) by adding pollutants at determined concentrations. Every pollutant was adsorbed almost quantitatively, and eluted by 3N HCl or methanol. From these results, we concluded that the powder of porous TiC ceramics is a useful reusable adsorbent for the water cleanup and solid-phase extraction. Copyright © 2010 Elsevier B.V. All rights reserved.

  5. Sorption of amitriptyline and amphetamine to mixed-mode solid-phase microextraction in different test conditions.

    PubMed

    Peltenburg, Hester; Droge, Steven T J; Hermens, Joop L M; Bosman, Ingrid J

    2015-04-17

    A solid-phase microextraction (SPME) method based on a sampler coating that includes strong cation groups (C18/SCX) is explored as a rapid direct sampling tool to detect and quantify freely dissolved basic drugs. Sampling kinetics, sorption isotherms and competitive effects on extraction yields in mixtures were tested for amphetamine and the relatively large/hydrophobic tricyclic antidepressant amitriptyline. Both compounds are >99% ionized at pH 7.4 but their affinity for the C18/SCX fiber is markedly different with distribution coefficients (Dfw values) of 2.49±0.02 for amphetamine and 4.72±0.10 for amitriptyline. Typical changes in electrolyte homeostasis that may occur in biomedical samples were simulated by altering pH and ionic composition (Na(+) and K(+) concentrations). These changes were shown to affect C18/SCX sorption affinities of the tested drugs with less than 0.2log units. At relatively low fiber loadings (<10mmol/L coating) and at all tested exposure times, linear sorption isotherms were obtained for both compounds but at aqueous concentrations of the individual drugs corresponding to concentrations in blood that are lethal, sorption isotherms became strongly nonlinear. Competition effects within binary mixtures occurred only if combinations of aqueous concentrations resulted in total fiber loadings that were in the nonlinear range of the SPME sorption isotherm for the individual compounds. We also compared sorption to the (prototype) C18/SCX SPME coating with analogue (biocompatible) C18 coated SPME fibers. C18/SCX fibers show increased sorption affinity for cationic compounds compared to C18 fibers, as tested using amitriptyline, amphetamine and trimethoprim. Surprisingly, sorption affinity of these ionized compounds for the C18 SPME fibers were within 1log unit of the C18/SCX SPME fibers. This shows that the strong cation exchange groups within the C18/SCX coating only has a relatively small contribution to the total sorption affinity of cationic compounds. Also the role of negatively charged silanol groups in both the C18 and C18/SCX coating seems small, as anionic diclofenac species sorbed strongly to the C18 fiber. Ionized organic species seem to be substantially adsorbed to the high surface area of C18 in SPME types using porous silica based coatings. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Sensitive method for the quantitative determination of bromocriptine in human plasma by liquid chromatography-tandem mass spectrometry.

    PubMed

    Salvador, Arnaud; Dubreuil, Didier; Denouel, Jannick; Millerioux, L

    2005-06-25

    A sensitive LC-MS-MS assay for the quantitative determination of bromocriptine has been developed and validated and is described in this work. The assay involved the extraction of the analyte from 1 ml of human plasma using a solid phase extraction on Oasis MCX cartridges. Chromatography was performed on a Symmetry C18 (2.1 mm x 100 mm, 3.5 microm) column using a mobile phase consisting of 25:75:01 acetonitrile-water-formic acid with a flow rate of 250 microl/min. The linearity was within the concentration range of 2-500 pg/ml. The lower limit of quantification was 2 pg/ml. This method has been demonstrated to be an improvement over existing methods due to its greater sensitivity and specificity.

  7. Determination of melatonin content in traditional Thai herbal remedies used as sleeping aids

    PubMed Central

    2014-01-01

    Background Melatonin content was screened in leaves of seven edible herbs used as sleeping aids in Thai traditional medicine. These plants are Piper nigrum L, Sesbania glandiflora (L.) Desv., Sesbania sesban (L.) Merr., Senna tora (L.) Roxb., Moringa oleifera Lam., Momordica charantia L. and Baccaurea ramiflora Lour. Dried leaves were extracted by sonication in methanol for six hours at room temperature, and then melatonin was purified by C18 solid phase extraction (SPE). Melatonin was then quantified by a validated RP-C18 HPLC method with fluorescent detection. Findings Melatonin contents in extracts of B. ramiflora, S. glandiflora, M. charantia, S. tora and S. sesban were 43.2, 26.3, 21.4, 10.5 and 8.7 ng/g of dry sample weight, respectively. The highest melatonin content was from P. nigrum extract (1092.7 ng/g of dry sample weight). Melatonin was not detected in the extract of M. oleifera. Melatonin identification was confirmed by ELISA. Conclusions Melatonin was found in six of the seven herbs in the traditional Thai sleeping recipe. One of these, P. nigrum, exhibited an encouragingly high amount of melatonin. PMID:24393215

  8. A new approach for the extraction of pollutants from wastewaters handled by the graphic industry.

    PubMed

    Monteiro, C; Ventura, C; Martins, F

    2013-06-15

    It is widely recognized that the Graphic Industry handles toxic products and produces, in its various operations, toxic wastes. These wastes can cause serious environmental damages and can lead to severe health problems. In this work we report an efficient, simple and cheap to run method for the removal of some of the most common pollutants involved in the various stages of the Graphic Industry production, using a Solid-Phase Extraction (SPE) methodology. We have determined equilibrium constants, K(eq), and adsorption (k(up)) and desorption (k(off)) rate constants for the extraction of benzene, xylene, toluene and ethylbenzene (BXTE) from water, using C18 disks. The removal of these compounds was monitored by UV-vis spectroscopy, at room temperature. Average extraction efficiencies were of 60% in a mixture of BXTEs and close to 80% when pollutants were assessed separately. Since the retention mechanism in the C18 disk is essentially governed by hydrophobic interactions between the compounds and the alkyl chains of the disk, we have also shown that these pollutants' lipophilicity plays an important role in the rationalization of their behavior during the extraction process. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Preparation of molecular imprinted polymers using bi-functional monomer and bi-crosslinker for solid-phase extraction of rutin.

    PubMed

    Zeng, Huan; Wang, Yuzhi; Liu, Xiaojie; Kong, Jinhuan; Nie, Chan

    2012-05-15

    Molecular imprinted polymers (MIPs) were prepared using rutin as the template, different reagents as the functional monomer and different reagents as the cross-linker by solution polymerization. Several parameters that would influence the performance of MIPs were investigated including the type of functional monomer (single or double) and cross-linker (single or double), and the molar ratio of the template, the functional monomer and the cross-linker. The optimum synthesis conditions of MIPs were found to be bi-monomers (acrylamide-co-2-vinyl pyridine, 3:1) and bi-crosslinker (ethylene glycol dimethacrylate-co-divinylbenzene, 3:1). The ratio of the template, the functional monomer and the cross-linker was found to be 1:6:20. MIPs synthesized under these conditions were filled into the cartridges as the adsorbents of solid-phase extraction (SPE). A competition test was conducted to authenticate the selectivity and the specificity of molecularly imprinted solid-phase extraction (MISPE) for rutin using the mixture solution of standard rutin and its structural analogs including quercetin, naringenin and kaempferol. Compared with purchased SPE including C(18), silica and PCX, MISPE showed better selectivity and enrichment property for rutin in the extracted solutions of Chinese medicinal plants than any others. The mean recoveries were 85.93% (RSD: 3.04%, n=3) for Saururus chinensis (Lour.) Bail and 88.61% (RSD: 3.36%, n=3) for Flos Sophorae, respectively, which indicated that the optimized rutin-MIPs possess the value of practical application. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. [Simultaneous determination of five synthetic sweeteners in food by solid phase extraction-high performance liquid chromatography-evaporative light scattering detection].

    PubMed

    Liu, Fang; Wang, Yan; Wang, Yuhong; Zhou, Junyi; Yan, Chao

    2012-03-01

    A high performance liquid chromatographic method with evaporative light scattering detection (HPLC-ELSD) was developed for the simultaneous determination of five synthetic sweeteners (acesulfame-K, saccharin sodium, sodium cyclamate, sucralose and aspartame) in food. The sweeteners were extracted by 0.1% (v/v) formic acid buffer solution. The extract of sample was cleaned up and concentrated with solid phase extraction (SPE) cartridge. Then the sweeteners were separated on a C18 column (3 microm) using 0.1% (v/v) formic acid buffer (adjusted to pH = 3.5 with aqueous ammonia solution)-methanol (61: 39, v/v) as mobile phase, and finally detected by ELSD. The results showed that the reasonable linearity was achieved for all the analytes over the range of 30 - 1000 mg/L with the correlation coefficients (r) greater than 0.997. The recoveries for the five sweeteners ranged from 85.6% to 109.0% at three spiked concentrations with the relative standard deviations (RSDs) lower than 4.0%. The limits of detection (LODs, S/N = 3) were 2.5 mg/L for both acesulfame-K and sucralose, 3 mg/L for saccharin sodium, 10 mg/L for sodium cyclamate, and 5 mg/L for aspartame. The method is simple, sensitive and low cost, and has been successfully applied to the simultaneous determination of the five synthetic sweeteners in food.

  11. [Liquid chromatography-tandem mass spectrometry method for determination of 10 macrolide antibiotics in pork samples using on-line solid phase extraction purification].

    PubMed

    Zhang, Xiaoguang; Liu, Dong; Liu, Hongran; Li, Qiang; Li, Lili; Wang, Lixia; Zhang, Yan

    2017-10-08

    A high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method based on-line solid phase extraction (SPE) purification was established to determine 10 macrolide antibiotics in pork samples. The samples were extracted with acetonitrile, and the extracts were dried with rotary evaporator at 40℃, then the analytes were dissolved with 2 mL phosphate buffer. The solutions were purified and concentrated by on-line SPE with HLB cartridges. The analytes were eluted with methanol, and then transferred to XBridge BEH C18 column, separated with the mobile phases of 10 mmol/L ammonium acetate aqueous solution and acetonitrile. Finally, the target analytes were detected by tandem mass spectrometry. The results showed that good linearity was obtained in the range of 0.1-200 μg/L for the 10 macrolide antibiotics with correlation coefficients better than 0.990. The limits of detection were in range of 0.05-0.30 μg/kg and the limits of quantitation were in range of 0.10-1.00 μg/kg. The recoveries of the method were in range of 69.6%-115.2% at the spiked levels of 0.10-10.0 μg/kg for all analytes, with the relative standard deviations less than 10%. The developed method can be used for the determination of the 10 macrolide antibiotics in pork samples.

  12. Synthesis and application of mesoporous molecular sieve for miniaturized matrix solid-phase dispersion extraction of bioactive flavonoids from toothpaste, plant, and saliva.

    PubMed

    Cao, Wan; Cao, Jun; Ye, Li-Hong; Xu, Jing-Jing; Hu, Shuai-Shuai; Peng, Li-Qing

    2015-12-01

    This article describes the use of the mesoporous molecular sieve KIT-6 as a sorbent in miniaturized matrix solid-phase dispersion (MSPD) in combination with ultra-performance LC for the determination of bioactive flavonoids in toothpaste, Scutellariae Radix, and saliva. In this study, for the first time, KIT-6 was used as a sorbent material for this mode of extraction. Compared with common silica-based sorbents (C18 and activated silica gel), the proposed KIT-6 dispersant with a three-dimensional cubic Ia3d structure and highly ordered arrays of mesoporous channels exhibits excellent adsorption capability of the tested compounds. In addition, several experimental variables, such as the mass ratio of sample to dispersant, grinding time, and elution solvent, were optimized to maximize the extraction efficiency. The proposed analytical method is simple, fast, and entails low consumption of samples, dispersants and elution solvents, thereby meeting "green chemistry" requirements. Under the optimized conditions, the recoveries of three bioactive flavonoids obtained by analyzing the spiked samples were from 89.22 to 101.17%. Also, the LODs and LOQs for determining the analytes were in the range of 0.02-0.04 μg/mL and 0.07-0.13 μg/mL, respectively. Finally, the miniaturized matrix solid-phase dispersion method was successfully applied to the analysis of target solutes in real samples, and satisfactory results were obtained. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Fingerprinting of traditional Chinese medicines on the C18-Diol mixed-mode column in online or offline two-dimensional liquid chromatography on the single column modes.

    PubMed

    Wang, Qing; Tong, Ling; Yao, Lin; Zhang, Peng; Xu, Li

    2016-06-05

    In the present study, a mixed-mode stationary phase, C18-Diol, was applied for fingerprint analysis of traditional Chinese medicines. Hydrophobic, hydrogen bonding and electrostatic interactions were demonstrated to contribute the retention separately or jointly, which endowed the C18-Diol stationary phase with distinct selectivity compared to the bare C18 one. The separation of total alkaloids extracted from Fritillaria hupehensis was compared on the C18-Diol and conventional C18 column with the greater resolving power and better symmetry responses on the former one. Besides, a novel two-dimensional liquid chromatography on the single column (2D-LC-1C) was realized on C18-Diol with the offline mode for the alcohol extract of Fritillaria hupehensis and online mode for Ligusticum chuanxiong Hort. The early co-eluted extracted components with great polarity on the first dimension were reinjected on the same column and well separated on the second dimension. The results exhibited that the two complementary RPLC and HILIC modes on C18-Diol stationary phase enhanced the separation capacity and revealed more abundant chemical information of the sample, which was a powerful tool in analyzing complex herbal medicines. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Determination of phosphatidylethanolamine molecular species in various food matrices by liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS2).

    PubMed

    Zhou, Li; Zhao, Minjie; Ennahar, Saïd; Bindler, Françoise; Marchioni, Eric

    2012-04-01

    A liquid chromatographic-electrospray ionization-tandem mass spectrometric (LC-ESI-MS(2)) method has been developed for determination of the molecular species of phosphatidylethanolamine (PE) in four food matrices (soy, egg yolk, ox liver, and krill oil). The extraction and purification method consisted of a pressurized liquid extraction procedure for total lipid (TL) extraction, purification of phospholipids (PLs) by adsorption on a silica gel column, and separation of PL classes by semi-preparative normal-phase HPLC. Separation and identification of PE molecular species were performed by reversed-phase HPLC coupled with electrospray ionization tandem mass spectrometry (ESI-MS(2)). Methanol containing 5 mmol L(-1) ammonium formate was used as the mobile phase. A variety of PE molecular species were detected in the four food matrices. (C16:0-C18:2)PE, (C18:2-C18:2)PE, and (C16:0-C18:1)PE were the major PE molecular species in soy. Egg yolk PE contained (C16:0-C18:1)PE, (C18:0-C18:1)PE, (C18:0-C18:2)PE, and (C16:0-C18:2)PE as the major molecular species. Ox liver PE was rich in the species (C18:0-C18:1)PE, (C18:0-C20:4)PE, and (C18:0-C18:2)PE. Finally, krill oil which was particularly rich in (C16:0(alkyl)-C22:6(acyl))plasmanylethanolamine (PakE), (C16:0-C22:6)PE, and (C16:0-C20:5)PE, seemed to be an interesting potential source for supplementation of food with eicosapentaenoic acid and docosahexaenoic acid.

  15. Ultrasound-assisted extraction and solid-phase extraction for the simultaneous determination of five amide herbicides in fish samples by gas chromatography with electron capture detection.

    PubMed

    Qu, Zhipeng; Bai, Xiuzhi; Zhang, Ting; Yang, Zhaoguang

    2017-03-01

    An efficient sample extraction and clean-up method was developed for simultaneous determination of five amide herbicides (alachlor, acetochlor, propisochlor, metazachlor, and butachlor) in fish samples. The protocol consisted of ultrasound-assisted solvent extraction and solid-phase extraction clean-up. In detail, aliquots of homogenized fish flesh were thoroughly mixed with 20 mL of n-hexane and then extracted with ultrasonication for 40 min. Each sample was centrifuged and the supernatant was collected for the subsequent clean-up. For the sample preparation, the above supernatant was processed with a C 18 column with 3 mL of dichloromethane/n-hexane (1:1, v/v) as the eluant. Then the samples were analyzed by gas chromatography with electron capture detection. The correlation coefficients of the five calibration curves were 0.9976-0.9998 (n = 3). The limits of detection (S/N = 3, n = 11) and limits of quantification (S/N = 10, n = 11) were 0.19-0.42 and 0.63-1.39 μg/kg, respectively. The recoveries of this method were 71.2-92.6% with good precision (<4.7% relative standard deviations, n = 6). The developed method was successfully applied to monitor the five amide herbicides in fish samples collected from different cities. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. [Multi-residue method for screening of pesticides in crops by liquid chromatography with tandem mass spectrometry].

    PubMed

    Tanizawa, Haruna; Shima, Mikie; Ikehara, Chieko; Kobata, Masakazu; Sato, Motoaki

    2005-10-01

    A simple and rapid method was developed for the screening of 82 pesticides/metabolites in a wide variety of crops, using solid-phase extraction and liquid chromatography with tandem mass spectrometry (LC/MS/MS). After extraction with methanol, the filtered extracts were made up to 100 mL and a 2 mL aliquot was subjected to solid-phase extraction. Co-extractives were removed with a C18 mini-column, while pesticides were retained on 3 kinds of mini-columns (HLB, SAX, activated carbon), and then eluted with acetonitrile. Analysis was performed by LC/MS/MS, and MS acquisition parameters were established in positive and negative ESI modes. The utility of the method was demonstrated by the analysis of 6 crops (carrot, cabbage, onion, spinach, lemon, brown rice) and one mixed vegetable juice. Of 82 compounds tested, 75 in carrot and 62 in lemon were obtained with recoveries ranging from 70-120%. For all samples tested, 75 compounds could be obtained with recoveries of over 50%, and the detection limits of most compounds were lower than 0.01 microg/g. This method provides acceptable performance for analysis of these 75 compounds. Further, by using aliquots of the extracts with small-scale mini-columns, purified samples could be obtained. This proposed method with small matrix effects, is effective and suitable for screening of multiple residual pesticides by using LC/MS/MS.

  17. Solid phase extraction of magnetic carbon doped Fe3O4 nanoparticles.

    PubMed

    Yang, Jing; Li, Jia-yuan; Qiao, Jun-qin; Lian, Hong-zhen; Chen, Hong-yuan

    2014-01-17

    Carbon decorated Fe3O4 nanoparticles (Fe3O4/C) are promising magnetic solid-phase extraction (MSPE) sorbents in environmental and biological analysis. Fe3O4/C based MSPE method shows advantages of easy operation, rapidness, high sensitivity, and environmental friendliness. In this paper, the MSPE mechanism of Fe3O4/C nanoparticles has been comprehensively investigated, for the first time, through the following three efforts: (1) the comparison of extraction efficiency for polycyclic aromatic hydrocarbons (PAHs) between the Fe3O4/C sorbents and activated carbon; (2) the chromatographic retention behaviors of hydrophobic and hydrophilic compounds on Fe3O4/C nanoparticles as stationary phase; (3) related MSPE experiments for several typical compounds such as pyrene, naphthalene, benzene, phenol, resorcinol, anisole and thioanisole. It can be concluded that there are hybrid hydrophobic interaction and hydrogen bonding interaction or dipole-dipole attraction between Fe3O4/C sorbents and analytes. It is the existence of carbon and oxygen-containing functional groups coated on the surface of Fe3O4/C nanoparticles that is responsible for the effective extraction process. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Reversed-Phase High-Performance Liquid Chromatography for the Quantification and Optimization for Extracting 10 Kinds of Carotenoids in Pepper (Capsicum annuum L.) Leaves.

    PubMed

    Li, Jing; Xie, Jianming; Yu, Jihua; Lv, Jian; Zhang, Junfeng; Wang, Xiaolong; Wang, Cheng; Tang, Chaonan; Zhang, Yingchun; Dawuda, Mohammed Mujitaba; Zhu, Daiqiang; Ma, Guoli

    2017-09-27

    Carotenoids are considered to be crucial elements in many fields and, furthermore, the significant factor in pepper leaves under low light and chilling temperature. However, little literature focused on the method to determinate and extract the contents of carotenoid compositions in pepper leaves. Therefore, a time-saving and highly sensitive reversed-phase high-performance liquid chromatography method for separation and quantification of 10 carotenoids was developed, and an optimized technological process for carotenoid composition extraction in pepper leaves was established for the first time. Our final method concluded that six xanthophylls eluted after about 9-26 min. In contrast, four carotenes showed higher retention times after nearly 28-40 min, which significantly shortened time and improved efficiency. Meanwhile, we suggested that 8 mL of 20% KOH-methanol solution should be added to perform saponification at 60 °C for 30 min. The ratio of solid-liquid was 1:8, and the ultrasound-assisted extraction time was 40 min.

  19. [Determination of canthaxanthin and astaxanthin in egg yolks by reversed phase high performance liquid chromatography with diode array detection].

    PubMed

    He, Kang-Hao; Zou, Xiao-Li; Liu, Xiang; Zeng, Hong-Yan

    2012-01-01

    A method using reversed phase high performance liquid chromatography (RP-HPLC) coupled with diode array detector (DAD) was developed for the simultaneous determination of canthaxanthin and astaxanthin in egg yolks. Samples were extracted with acetonitrile in ultrasonic bath for 20 minutes and then purified by freezing-lipid filtration and solid phase extraction (SPE). After being vaporized to dryness by nitrogen blowing and made up to volume with methanol, the extract solution was chromatographically separated in C18 column with a unitary mobile phase consisting of acetonitrile. The proposed method was validated in terms of linearity, precision, accuracy, and limit of detection (LOD). Regression analysis revealed a good linearity between peak area of each analyte and its concentration (r > or = 0.998). The intra- and inter-day relative standard deviations (RSDs) were less than 3.6% and 5.2%, respectively. LODs of canthaxanthin and astaxanthin were 0.035 and 0.027 microg/mL (S/N = 3). The average recoveries of canthaxanthin and astaxanthin were 91.5% and 88.7%. The proposed method is simple, fast and easy to apply.

  20. Development and Validation of a Liquid Chromatography-Tandem Mass Spectrometry Method Coupled with Dispersive Solid-Phase Extraction for Simultaneous Quantification of Eight Paralytic Shellfish Poisoning Toxins in Shellfish

    PubMed Central

    Yang, Xianli; Zhou, Lei; Tan, Yanglan; Shi, Xizhi; Zhao, Zhiyong; Nie, Dongxia; Zhou, Changyan; Liu, Hong

    2017-01-01

    In this study, a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed for simultaneous determination of eight paralytic shellfish poisoning (PSP) toxins, including saxitoxin (STX), neosaxitoxin (NEO), gonyautoxins (GTX1–4) and the N-sulfo carbamoyl toxins C1 and C2, in sea shellfish. The samples were extracted by acetonitrile/water (80:20, v/v) with 0.1% formic and purified by dispersive solid-phase extraction (dSPE) with C18 silica and acidic alumina. Qualitative and quantitative detection for the target toxins were conducted under the multiple reaction monitoring (MRM) mode by using the positive electrospray ionization (ESI) mode after chromatographic separation on a TSK-gel Amide-80 HILIC column with water and acetonitrile. Matrix-matched calibration was used to compensate for matrix effects. The established method was further validated by determining the linearity (R2 ≥ 0.9900), average recovery (81.52–116.50%), sensitivity (limits of detection (LODs): 0.33–5.52 μg·kg−1; limits of quantitation (LOQs): 1.32–11.29 μg·kg−1) and precision (relative standard deviation (RSD) ≤ 19.10%). The application of this proposed approach to thirty shellfish samples proved its desirable performance and sufficient capability for simultaneous determination of multiclass PSP toxins in sea foods. PMID:28661471

  1. Liquid chromatographic method for determining the concentration of bisazir in water

    USGS Publications Warehouse

    Scholefield, Ronald J.; Slaght, Karen S.; Allen, John L.

    1997-01-01

    Barrier dams, traps, and lampricides are the techniques currently used by the Great Lakes Fishery Commission to control sea lampreys (Petromyzon marinus) in the Great Lakes. To augment these control techniques, a sterile-male-release research program was initiated at the Lake Huron Biological Station. Male sea lampreys were sterilized by intraperitoneal injection of the chemical sterilant P,P-bis(1-aziridinyl)-N-methylphosphinothioic amide (bisazir). An analytical method was needed to quantitate the concentration of bisazir in water and to routinely verify that bisazir (>25 μg/L) does not persist in the treated effluent discharged from the sterilization facility to Lake Huron. A rapid, accurate, and sensitive liquid chromatographic (LC) method was developed for determining bisazir in water. Bisazir was dissolved in Lake Huron water; extracted and concentrated on a C18 solid-phase extraction column; eluted with methanol; and quantitated by reversed-phase LC using a C18 column, a mobile phase of 70% water and 30% methanol (v/v), and UV detection (205 nm). Bisazir retention time was 7-8 min; total run time was about 20 min. Method detection limit for bisazir dissolved in Lake Huron water was about 15 μg/L. Recovery from Lake Huron water fortified with bisazir at 100 μg/L was 94% (95% confidence interval, 90.2-98.2%).

  2. Evaluation of a new carbon/zirconia-based sorbent for the cleanup of food extracts in multiclass analysis of pesticides and environmental contaminants.

    PubMed

    Han, Lijun; Sapozhnikova, Yelena; Matarrita, Jessie

    2016-12-01

    A novel carbon/zirconia-based material, Supel TM QuE Verde, was evaluated in a filter-vial dispersive solid-phase extraction cleanup of pork, salmon, kale, and avocado extracts for the residual analysis of 65 pesticides and 52 environmental contaminants (flame retardants, polychlorinated biphenyls, polybrominated diphenyl ethers, and polycyclic aromatic hydrocarbons) using low-pressure gas chromatography with tandem mass spectrometry. An amount of 180 mg sorbent per 0.6 mL extract in filter-vial dispersive solid-phase extraction cleanup was found the optimum in terms of achieving satisfactory removal of co-extractives and recoveries of analytes, especially for structurally planar compounds. For analytes partially retained by Verde, normalization to an internal standard resulted in 62-107% recoveries. Addition of Verde to primary secondary amine and C 18 in cleanup resulted in 38% more removal of gas-chromatography-amenable co-extractives in avocado, 30% in kale, 39% in salmon, and 50% in pork. The removal efficiency of co-extracted chlorophyll was 93% for kale and 64% for avocado based on ultraviolet-visible absorbance. The developed method was validated at three spiking levels (10, 25, and 100 ng/g), and 70-120% recoveries with ≤20% relative standard deviation were achieved for 96 (83%) out of 117 analytes in pork, 79 (69%) in salmon, 71 (62%) in kale, and 75 (65%) in avocado. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. A new solid-phase extraction disk based on a sheet of single-walled carbon nanotubes.

    PubMed

    Niu, Hong Yun; Cai, Ya Qi; Shi, Ya Li; Wei, Fu Sheng; Liu, Jie Min; Jiang, Gui Bin

    2008-11-01

    A new kind of solid-phase extraction disk based on a sheet of single-walled carbon nanotubes (SWCNTs) is developed in this study. The properties of such disks are tested, and different disks showed satisfactory reproducibility. One liter of aqueous solution can pass through the disk within 10-100 min while still allowing good recoveries. Two disks (DD-disk) can be stacked to enrich phthalate esters, bisphenol A (BPA), 4-n-nonylphenol (4-NP), 4-tert-octylphenol (4-OP) and chlorophenols from various volumes of solution. The results show that SWCNT disks have high extraction ability for all analytes. The SWCNT disk can extract polar chlorophenols more efficiently than a C(18) disk from water solution. Unlike the activated carbon disk, analytes adsorbed by the new disks can be eluted completely with 8-15 mL of methanol or acetonitrile. Finally, the DD-disk system is used to pretreat 1000-mL real-world water samples spiked with BPA, 4-OP and 4-NP. Detection limits of 7, 25, and 38 ng L(-1) for BPA, 4-OP, and 4-NP, respectively, were achieved under optimized conditions. The advantages of this new disk include its strong adsorption ability, its high flow rate and its easy preparation.

  4. Cesium and strontium extraction using a mixed extractant solvent including crown ether and calixarene extractants

    DOEpatents

    Meikrantz, David H.; Todd, Terry A.; Riddle, Catherine L.; Law, Jack D.; Peterman, Dean R.; Mincher, Bruce J.; McGrath, Christopher A.; Baker, John D.

    2007-11-06

    A mixed extractant solvent including calix[4]arene-bis-(tert-octylbenzo)-crown-6 ("BOBCalixC6"), 4',4',(5')-di-(t-butyldicyclo-hexano)-18-crown-6 ("DtBu18C6"), and at least one modifier dissolved in a diluent. The mixed extractant solvent may be used to remove cesium and strontium from an acidic solution. The DtBu18C6 may be present from approximately 0.01 M to approximately 0.4M, such as from approximately 0.086 M to approximately 0.108 M. The modifier may be 1-(2,2,3,3-tetrafluoropropoxy)-3-(4-sec-butylphenoxy)-2-propanol ("Cs-7SB") and may be present from approximately 0.01M to approximately 0.8M. In one embodiment, the mixed extractant solvent includes approximately 0.15M DtBu18C6, approximately 0.007M BOBCalixC6, and approximately 0.75M Cs-7SB modifier dissolved in an isoparaffinic hydrocarbon diluent. The mixed extractant solvent may form an organic phase in an extraction system that also includes an aqueous phase. Methods of extracting cesium and strontium as well as strontium alone are also disclosed.

  5. Development and validation of an HPLC method for the simultaneous determination of tocopherols, tocotrienols and carotenoids in cereals after solid-phase extraction.

    PubMed

    Irakli, Maria N; Samanidou, Victoria F; Papadoyannis, Ioannis N

    2011-06-01

    The increasing interest in antioxidant properties of cereal and cereal-based products has prompted the development of a simple and reliable HPLC method for the simultaneous determination of important phytochemicals like tocopherols (T), tocotrienols (T3) and carotenoids. Separation was carried out on a Nucleosil 100 C(18) column, 5 μm (250 mm × 4.6 mm) thermostated at 25 °C, using a linear gradient elution system starting with methanol and ending with a mixture of methanol-isopropanol-acetonitrile. All separated compounds including the internal standard (α-tocopherol acetate) were eluted within 16 min and detected by dual detection: fluorescence for tocopherols and tocotrienols at 290 nm excitation and 320 nm emission and UV-vis photodiode array detection for lutein and β-carotene at 450 nm. Detection limits ranged from 0.2 μg/g (β-carotene) to 1.60 μg/g (α-tocopherol). The intra- and inter-assay coefficients of variation were calculated by using cereals with different levels of lipophilic antioxidants. The extraction method involved sample saponification and clean-up by solid-phase extraction (SPE). The extraction recoveries obtained using OASIS HLB SPE cartridges and dichloromethane as eluent were in the range of 90.2-110.1%, with RSD lower than 10%. The method was successfully applied to cereals: durum wheat, bread wheat, rice, barley, oat, rye, corn and triticale. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Large-scale pesticide testing in olives by liquid chromatography-electrospray tandem mass spectrometry using two sample preparation methods based on matrix solid-phase dispersion and QuEChERS.

    PubMed

    Gilbert-López, Bienvenida; García-Reyes, Juan F; Lozano, Ana; Fernández-Alba, Amadeo R; Molina-Díaz, Antonio

    2010-09-24

    In this work we have evaluated the performance of two sample preparation methodologies for the large-scale multiresidue analysis of pesticides in olives using liquid chromatography-electrospray tandem mass spectrometry (LC-MS/MS). The tested sample treatment methodologies were: (1) liquid-liquid partitioning with acetonitrile followed by dispersive solid-phase extraction clean-up using GCB, PSA and C18 sorbents (QuEChERS method - modified for fatty vegetables) and (2) matrix solid-phase dispersion (MSPD) using aminopropyl as sorbent material and a final clean-up performed in the elution step using Florisil. An LC-MS/MS method covering 104 multiclass pesticides was developed to examine the performance of these two protocols. The separation of the compounds from the olive extracts was achieved using a short C18 column (50 mm x 4.6 mm i.d.) with 1.8 microm particle size. The identification and confirmation of the compounds was based on retention time matching along with the presence (and ratio) of two typical MRM transitions. Limits of detection obtained were lower than 10 microgkg(-1) for 89% analytes using both sample treatment protocols. Recoveries studies performed on olives samples spiked at two concentration levels (10 and 100 microgkg(-1)) yielded average recoveries in the range 70-120% for most analytes when QuEChERS procedure is employed. When MSPD was the choice for sample extraction, recoveries obtained were in the range 50-70% for most of target compounds. The proposed methods were successfully applied to the analysis of real olives samples, revealing the presence of some of the target species in the microgkg(-1) range. Besides the evaluation of the sample preparation approaches, we also discuss the use of advanced software features associated to MRM method development that overcome several limitations and drawbacks associated to MS/MS methods (time segments boundaries, tedious method development/manual scheduling and acquisition limitations). This software feature recently offered by different vendors is based on an algorithm that associates retention time data for each individual MS/MS transition, so that the number of simultaneously traced transitions throughout the entire chromatographic run (dwell times and sensitivity) is maximized. Copyright 2010 Elsevier B.V. All rights reserved.

  7. Evaluation of two fast and easy methods for pesticide residue analysis in fatty food matrixes.

    PubMed

    Lehotay, Steven J; Mastovská, Katerina; Yun, Seon Jong

    2005-01-01

    Two rapid methods of sample preparation and analysis of fatty foods (e.g., milk, eggs, and avocado) were evaluated and compared for 32 pesticide residues representing a wide range of physicochemical properties. One method, dubbed the quick, easy, cheap, effective, rugged, and safe (QuEChERS) method for pesticide residue analysis, entailed extraction of 15 g sample with 15 mL acetonitrile (MeCN) containing 1% acetic acid followed by addition of 6 g anhydrous magnesium sulfate and 1.5 g sodium acetate. After centrifugation, 1 mL of the buffered MeCN extract underwent a cleanup step (in a technique known as dispersive solid-phase extraction) using 50 mg each of C18 and primary secondary amine sorbents plus 150 mg MgSO4. The second method incorporated a form of matrix solid-phase dispersion (MSPD), in which 0.5 g sample plus 2 g C18 and 2 g anhydrous sodium sulfate was mixed in a mortar and pestle and added above a 2 g Florisil column on a vacuum manifold. Then, 5 x 2 mL MeCN was used to elute the pesticide analytes from the sample into a collection tube, and the extract was concentrated to 0.5 mL by evaporation. Extracts in both methods were analyzed concurrently by gas chromatography/mass spectrometry and liquid chromatography/tandem mass spectrometry. The recoveries of semi-polar and polar pesticides were typically 100% in both methods (except that basic pesticides, such as thiabendazole and imazalil, were not recovered in the MSPD method), but recovery of nonpolar pesticides decreased as fat content of the sample increased. This trend was more pronounced in the QuEChERS method, in which case the most lipophilic analyte tested, hexachlorobenzene, gave 27 +/- 1% recovery (n=6) in avocado (15% fat) with a<10 ng/g limit of quantitation.

  8. Simultaneous determination of bisphenols and alkylphenols in water by solid phase extraction and ultra performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Shan, Xiao Mei; Shen, Deng Hui; Wang, Bing Shuang; Lu, Bei Bei; Huang, Fa Yuan

    2014-06-01

    To establish an analytical method for determination of four bisphenols (BPA, BPB, BPF, and BPS) and two alkylphenols (4-n-OP, 4-n-NP) in water by ultra performance liquid chromatography- tandem mass spectrometry (UPLC/MS/MS). The water samples were extracted and condensed with solid-phase extraction (SPE) using C18 cartridges and eluted by acetonitrile. Separation was carried out with Acquity BEH C8 column and detection were performed by UPLC/MS/MS. Quantification was calculated by using the internal standard BPA-d16 and 4-n-NP-d8. The linear correlation coefficients of these compounds in the range of 1.0-100.0 μg/L were all over 0.999. The minimum detectable concentrations were 0.75-1.0 ng/L, and the recoveries ranged from 87.0% to 106.9%. Relative standard deviations (RSDs) were between 1.26% and 3.67%. Applying this method to detect the source water of Chaohu Lake and drinking water of Hefei, six target compounds were detected in different levels. This method is simple with high sensitivity and selectivity, could be suitable for the determination of these compounds in source and drinking water. Copyright © 2014 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.

  9. A platinized stainless steel fiber with in-situ coated polyaniline/polypyrrole/graphene oxide nanocomposite sorbent for headspace solid-phase microextraction of aliphatic aldehydes in rice samples.

    PubMed

    Ghiasvand, Alireza; Nasirian, Afagh; Koonani, Samira; Nouriasl, Kolsoum

    2017-12-01

    The surface of a stainless steel fiber was made larger, porous and cohesive by platinizing for tight attachment of its coating. Then it was coated by a polyaniline/polypyrrole/graphene oxide (PANI/PP/GO) nanocomposite film using electrochemical polymerization. The prepared PANI/PP/GO fiber was used for headspace solid-phase microextraction (HS-SPME) of linear aliphatic aldehydes in rice samples followed by GC-FID determination. To achieve the highest extraction efficiency, various experimental parameters including extraction time and temperature, matrix modifier and desorption condition were studied. The linear calibration curves were obtained over the range of 0.05-20 μg g -1 (R 2  > 0.99) for C 4 -C 11 aldehydes. The limits of detection were found to be in the range of 0.01-0.04 μg g -1 . RSD values were calculated to be <7.4 and 10.7% for intra- and inter-day, respectively. The superiority of the prepared nanocomposite SPME fiber was established by comparison of its results with those obtained by polydimethylsiloxane, carbowax-divinylbenzene, divinylbenzene-carboxen-polydimethylsiloxane and polyacrylate commercial ones. Finally, the nanocomposite fiber was used to extract and determine linear aliphatic aldehydes in 18 rice samples. Copyright © 2017 John Wiley & Sons, Ltd.

  10. Method of analysis and quality-assurance practices for determination of pesticides in water by solid-phase extraction and capillary-column gas chromatography/mass spectrometry at the U.S. Geological Survey California District Organic Chemistry Laboratory, 1996-99

    USGS Publications Warehouse

    Crepeau, Kathryn L.; Baker, Lucian M.; Kuivila, Kathryn

    2000-01-01

    A method of analysis and quality-assurance practices were developed to study the fate and transport of pesticides in the San Francisco Bay-Estuary by the U.S. Geological Survey. Water samples were filtered to remove suspended-particulate matter and pumped through C-8 solid-phase extraction cartridges to extract the pesticides. The cartridges were dried with carbon dioxide and the pesticides were eluted with three cartridge volumes of hexane:diethyl ether (1:1) solution. The eluants were analyzed using capillary-column gas chromatography/mass spectrometry in full-scan mode. Method detection limits for pesticides ranged from 0.002 to 0.025 microgram per liter for 1-liter samples. Recoveries ranged from 44 to 140 percent for 25 pesticides in samples of organic-free reagent water and Sacramento-San Joaquin Delta and Suisun Bay water fortified at 0.05 and 0.50 microgram per liter. The estimated holding time for pesticides after extraction on C-8 solid-phase extraction cartridges ranged from 10 to 257 days.

  11. Determination of pyrethrin and pyrethroid residues in animal fat using liquid chromatography coupled to tandem mass spectrometry.

    PubMed

    Moloney, M; Tuck, S; Ramkumar, A; Furey, A; Danaher, M

    2018-03-01

    A method was developed for the confirmatory and quantitative analysis of one pyrethrin and 18 pyrethroid residues in animal fat. Fat was extracted was collected from adipose tissue melted in an oven at 65 °C for 2 h. Fat samples (1 g) were dispersed with deactivated Florisil ® sorbent and extracted with MeCN. Sample extracts were purified by cold temperature precipitation at -30 °C for 4 h and further purified using dispersive solid-phase extraction (d-SPE) clean-up in tubes containing 500 mg of Z-SEP+ and 125 mg of PSA bonded silica. Purified samples were analysed by ultra-high performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS) detection. Chromatographic separation was carried out on a Acquity C 8 BEH column, using a binary gradient separation comprising of mobile phase A, 5 mM ammonium formate in water:MeOH (80:20, v/v,) and mobile phase B, 5 mM ammonium formate in MeOH. The mass spectrometer was operated in the positive electrospray ionisation mode (ESI(+)). Validation was performed following the 2002/657/EC guidelines. Trueness ranged between 84% and 143% and precision ranged between 3.9% and 29%. The developed method is particularly advantageous because the sample preparation procedure does not require complex sample extraction equipment and uses less solvent compared to other sample preparation protocols. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Improved method for the extraction and chromatographic analysis on a fused-core column of ellagitannins found in oak-aged wine.

    PubMed

    Navarro, María; Kontoudakis, Nikolaos; Canals, Joan Miquel; García-Romero, Esteban; Gómez-Alonso, Sergio; Zamora, Fernando; Hermosín-Gutiérrez, Isidro

    2017-07-01

    A new method for the analysis of ellagitannins observed in oak-aged wine is proposed, exhibiting interesting advantages with regard to previously reported analytical methods. The necessary extraction of ellagitannins from wine was simplified to a single step of solid phase extraction (SPE) using size exclusion chromatography with Sephadex LH-20 without the need for any previous SPE of phenolic compounds using reversed-phase materials. The quantitative recovery of wine ellagitannins requires a combined elution with methanol and ethyl acetate, especially for increasing the recovery of the less polar acutissimins. The chromatographic method was performed using a fused-core C18 column, thereby avoiding the coelution of main ellagitannins, such as vescalagin and roburin E. However, the very polar ellagitannins, namely, the roburins A, B and C, still partially coeluted, and their quantification was assisted by the MS detector. This methodology also enabled the analysis of free gallic and ellagic acids in the same chromatographic run. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Sensitized chemiluminescence of 2-phenyl-4,5-di(2-furyl)-1H-imidazole/K₃Fe(CN)₆/propyl gallate system combining with solid-phase extraction for the determination of propyl gallate in edible oil.

    PubMed

    Kang, Jing; Han, Lu; Chen, Zhonglin; Shen, Jimin; Nan, Jun; Zhang, Yihua

    2014-09-15

    In this paper, a novel chemiluminescence (CL) method has been developed for the determination of propyl gallate (PG). The proposed method was based on the enhancing effect of PG on the CL signal of 2-phenyl-4,5-di(2-furyl)-1H-imidazole (PDFI) and K3Fe(CN)6 reaction in an alkaline solution. Under the optimum conditions, the enhanced CL intensity was linearly related to the concentration of PG. The linear range of the calibration curve was 0.05-8 μg/mL, and the corresponding detection limit (3σ) was 0.036 μg/mL. The relative standard deviation for determining 1.0 μg/mL PG was 2.8% (n=11). The proposed method has been successfully applied to the determination of PG in edible oil. The edible oil samples were prepared by the solid-phase extraction (SPE) with a C18 column served as the stationary phase. Furthermore, the possible CL mechanism was also discussed briefly based on the photoluminescence (PL) and CL spectra. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. [Improvement of the method for methylmercury determination in aquatic products using liquid chromatography online coupled with atomic fluorescence spectrometry].

    PubMed

    Shang, Xiaohong; Zhao, Yunfeng; Zhang, Lei; Li, Xiaowei; Wu, Yongning

    2011-07-01

    The improvement method was developed for methylmercury determination using liquid chromatography online coupled with cold vapor atomic fluorescence spectrometry (LC-CV-AFS). Cysteine was used as complexing agent in mobile phase instead of mercaptoethanol. Under the optimized conditions, baseline separation of mercury species could be achieved within 8 min on a C18 column with a mobile phase of 5% (v/v) acetonitrile-1 g/L L-cysteine-50 mmol/L ammonium acetate aqueous solution. The linear range of calibration curve of methylmercury was 1-50 microg/L and the limit of detection (S/N = 3) for methylmercury was 0.3 microg/L. Ultrasonication assisted hydrochloric acid extraction was used to extract methylmercury from seafood samples. The sample extract was cleaned up by a C18 solid phase extraction (SPE) cartridge. For validation of the method, certified reference materials and spiked seafood samples were analyzed. The determined methylmercury contents of certified reference materials NIST1566b, BCR464 and GBW10029 agreed well with the certified values. The determined methylmercury values for Food Analysis Performance Assessment Scheme (FAPAS) sample 07115 were satisfied. The recoveries of methylmercury in seafood samples at three spiked levels (10, 50 and 500 microg/kg) ranged from 89% to 112%, including cooked seafood food. The precision of the method based on relative standard deviation (RSD) was not more than 7%. The present method of LC-CV-AFS is accurate, sensitive, simple, and can meet the demand of methylmercury determination in seafood.

  15. A validated solid-phase extraction HPLC method for the simultaneous determination of the citrus flavanone aglycones hesperetin and naringenin in urine.

    PubMed

    Kanaze, Feras Imad; Kokkalou, Eugene; Georgarakis, Manolis; Niopas, Ioannis

    2004-09-21

    A simple, specific, precise, accurate, and robust HPLC assay for the simultaneous analysis of hesperetin and naringenin in human urine was developed and validated. Urine samples were incubated with beta-glucuronidase/sulphatase and the analytes were isolated by solid-phase extraction using C18 cartridges and separated on a C8 reversed phase column using a mixture of methanol/water/acetic acid (40:58:2, v/v/v) at 45 degrees C. The method was found to be linear in the 50-1200 ng/ml concentration range for both hesperetin and naringenin (r > 0.999). The accuracy of the method was greater than 94.8%, while the intra- and inter-day precision for hesperetin was better than 4.9 and 8.2%, respectively and for naringenin was better than 5.3 and 7.8%, respectively. Recovery for hesperetin, naringenin and internal standard 7-ethoxycoumarin was greater than 70.9%. The method has been applied for the determination of hesperetin and naringenin in urine samples obtained from a male volunteer following a single 300 mg oral dose of each of the corresponding flavanone glycosides hesperidin and naringin. The intra- and inter-day reproducibility through enzyme hydrolysis was less than 3.9% for both total (free + conjugated) hesperetin and naringenin. Stability studies showed urine quality control samples to be stable for both hesperetin and naringenin through three freeze-thaw cycles and at room temperature for 24 h (error < or = 3.6%).

  16. Simultaneous estimation of E- and Z-isomers of guggulsterone in rabbit plasma using liquid chromatography tandem mass spectrometry and its application to pharmacokinetic study.

    PubMed

    Bhatta, R S; Kumar, D; Chhonker, Y S; Jain, G K

    2011-09-01

    A sensitive and selective liquid chromatography/tandem mass spectrometric method was developed for simultaneous determination of E- and Z-guggulsterone isomers (antihyperlipidemic drug) in rabbit plasma. Both the isomers were resolved on a Symmetry-Shield C(18) (5 µm, 4.6 × 150 mm) column, using gradient elution comprising a mobile phase of methanol, 0.5% v/v formic acid and acetonitrile. With dexamethasone as internal standard, plasma samples were extracted by an automated solid-phase extraction method using C(18) cartridges. Detection was performed by electrospray ionization in multiple reaction monitoring (MRM) in positive mode. The calibration curve was linear over the concentration range of 1.56-200 ng/mL (r(2) ≥ 0.998) for both analytes. The intra-day and inter-day accuracy and precision were within -0.96 to 4.12 (%bias) and 2.73 to 8.00 (%RSD) respectively. The analytes were stable after three freeze-thaw cycles. The method was successfully applied to study steriospecific pharmacokinetics of E- and Z-guggulsterone in NZ rabbit. Copyright © 2011 John Wiley & Sons, Ltd.

  17. An extractive removal step optimized for a high-throughput α-cellulose extraction method for δ 13 C and δ 18 O stable isotope ratio analysis in conifer tree rings

    Treesearch

    Wen Lin; Asko Noormets; John S. King; Ge Sun; Steve McNulty; Jean-Christophe Domec; Lucas Cernusak

    2017-01-01

    Stable isotope ratios (δ13C and δ18O) of tree-ring α-cellulose are important tools in paleoclimatology, ecology, plant physiology and genetics. The Multiple Sample Isolation System for Solids (MSISS) was a major advance in the tree-ring α-cellulose extraction methods, offering greater throughput and reduced labor input compared to traditional alternatives. However, the...

  18. Validation a solid-phase extraction-HPLC method for determining the migration behaviour of five aromatic amines from packaging bags into seafood simulants.

    PubMed

    OuYang, Xiao-Kun; Luo, Yu-Yang; Wang, Yang-Guang; Yang, Li-Ye

    2014-01-01

    The simultaneous determination of five aromatic amines and their potential migration from packaging bags into seafood simulants were investigated. A validated HPLC method was developed for the separation and qualification of five aromatic amines in seafood simulants. By combining solid-phase extraction (SPE), these amines were efficiently separated on a Halo C18 column (150 × 4.6 mm i.d., 2.7 μm, particle size) using a mobile phase of methanol/phosphate buffer solution (5 mmol l(-1), pH 6.9) with gradient elution. The linear range was 0.1-10.0 mg l(-1); the absolute recoveries ranged from 85.3% to 98.4%; and the limits of detection of the five aromatic amines were between 0.015 and 0.08 mg l(-1). In this work the migration profile of aromatic amines from black plastic bags was investigated at temperatures of 4°C with water, 3% acetic acid solution, 10% ethanol solution and 50% ethanol solution as seafood simulants, respectively. The migration of the five aromatic amines under different conditions showed that residual o-methoxyaniline, p-chloroaniline, aniline and 2,6-dimethylaniline leaching from black plastic bags increased with incubation time. No detectable 3,3´-dimethylbenzidine was found to leach from the bags.

  19. Fast trace determination of nine odorant and estrogenic chloro- and bromo-phenolic compounds in real water samples through automated solid-phase extraction coupled with liquid chromatography tandem mass spectrometry.

    PubMed

    Yuan, Su-Fen; Liu, Ze-Hua; Lian, Hai-Xian; Yang, Chuang-Tao; Lin, Qing; Yin, Hua; Lin, Zhang; Dang, Zhi

    2018-02-01

    A fast and reliable method was developed for simultaneous trace determination of nine odorous and estrogenic chloro- and bromo-phenolic compounds (CPs and BPs) in water samples using solid-phase extraction (SPE) coupled with liquid chromatography tandem mass spectrometry (LC-MS/MS). For sample preparation, the extraction efficiencies of two widely applied cartridges Oasis HLB and Sep-Pak C18 were compared, and the Oasis HLB cartridge showed much better extraction performance; pH of water sample also plays important role on extraction, and pH = 2-3 was found to be most appropriate. For separation of the target compounds, small addition of ammonium hydroxide can obviously improve the detection sensitivity, and the optimized addition concentration was determined as 0.2%. The developed efficient method was validated and showed excellent linearity (R 2  > 0.995), low limit of detection (LOD, 1.9-6.2 ng/L), and good recovery efficiencies of 57-95% in surface and tap water with low relative standard deviation (RSD, 1.3-17.4%). The developed method was finally applied to one tap and one surface water samples and most of these nine targets were detected, but all of them were below their odor thresholds, and their estrogen equivalent (EEQ) were also very low.

  20. A novel molybdenum disulfide nanosheet self-assembled flower-like monolithic sorbent for solid-phase extraction with high efficiency and long service life.

    PubMed

    Ran, Fanpeng; Liu, Hongmei; Wang, Xiaoqi; Guo, Yong

    2017-07-21

    A novel material consisting of molybdenum disulfide (MoS 2 ) nanosheet that self-assemble into flower-like microspheres which aggregate to form a monolithic matrix with a micro or nano-scaled mesopore structure was successfully synthesized and used as an efficient sorbent for solid-phase extraction (SPE) due to its large specific adsorption area and good stability. The extraction properties of the as-prepared sorbent were evaluated by high-performance liquid chromatography with variable wavelength detection (HPLC-VWD) by analyzing four flavonoids (apigenin, quercetin, luteolin, and kaempferol). Under optimal conditions, the LODs and LOQs were found to be in the ranges of 0.1-0.25 and 0.4-0.5μgL -1 , respectively, and wide linear ranges were obtained with correlation coefficients (R) ranging from 0.9991 to 0.9996. Compared with commercial C18 and Alumina-N sorbents, the as-prepared sorbent showed high extraction efficiency at different concentrations of flavonoids. After 100 uses, the extraction ability of the self-assembled MoS 2 nanosheet monolithic sorbent had no evident decline, denoting a long service life. Finally, the SPE-HPLC-VWD method using the as-prepared sorbent was applied to flavonoid analysis in beverage samples with satisfactory results. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. New materials for solid-phase extraction and multiclass high-performance liquid chromatographic analysis of pesticides in grapes.

    PubMed

    Melo, Lucio F C; Collins, Carol H; Jardim, Isabel C S F

    2004-04-02

    Sample preparation procedures which included the use of new aminopropyl (NH2) and octadecyl (C18) solid-phase extraction (SPE) sorbents are proposed for the simultaneous multiclass determination of the fungicide benomyl and of the herbicides tebuthiuron, diuron, simazine, atrazine, and ametryn in grapes, using single wavelength high-performance liquid chromatography. Sorbent preparation uses a fast, easy, and effective procedure to obtain silica-based materials, made by depositing polysiloxanes on a silica support followed by thermal immobilization. Recovery results of the compounds, after elution from the SPE cartridges, indicate that the most efficient system employed silica loaded with 40% of an aminofunctional polydimethylsiloxane as sorbent, using dichloromethane:methanol (95:5, v/v) as eluent. Method validation, carried out in agreement with International Conference on Harmonization directives, was performed at three fortification levels (100, 200, and 1000 microg kg(-1)). Limits of detection and quantification show that the method developed can be used to detect the pesticides at concentrations below the maximum residue levels established by Codex Alimentarius, the US Environmental Protection Agency, the European Union, and Brazilian legislation.

  2. Solid phase extraction--non-aqueous capillary electrophoresis for determination of metformin, phenformin and glyburide in human plasma.

    PubMed

    Lai, Edward P C; Feng, Sherry Y

    2006-10-20

    Solid phase extraction (SPE) was coupled at line to capillary electrophoresis (CE) for the determination of three basic and neutral diabetic drugs (metformin, phenformin and glyburide) in human plasma. The SPE procedure employed a C(18) cartridge to remove most of the water and proteins from the plasma sample. Analyte detectability was increased due to trace enrichment during the SPE process. Elution of metformin, phenformin and glyburide was achieved with methanol+3% acetic acid. CE analysis was performed using a non-aqueous buffer, acetonitrile+5mM ammonium acetate+5% acetic acid, which afforded rapid separation of metformin from phenformin within 3 min. Glyburide, with a migration time longer than 6 min, did not cause any interference. The present SPE-CE method, with an electrokinetic injection time of 6s and UV detection at 240 nm, was useful for monitoring down to 1 microg/mL of metformin and phenformin in human plasma. When the electrokinetic injection time was increased to 36s, the detection limits were improved to 12 ng/mL for metformin and 6 ng/mL for phenformin.

  3. Simultaneous analysis of different classes of phytohormones in coconut (Cocos nucifera L.) water using high-performance liquid chromatography and liquid chromatography-tandem mass spectrometry after solid-phase extraction.

    PubMed

    Ma, Zhen; Ge, Liya; Lee, Anna S Y; Yong, Jean Wan Hong; Tan, Swee Ngin; Ong, Eng Shi

    2008-03-10

    Coconut (Cocos nucifera L.) water, which contains many uncharacterized phytohormones is extensively used as a growth promoting supplement in plant tissue culture. In this paper, a high-performance liquid chromatography (HPLC) method was developed for the simultaneous determination of various classes phytohormones, including indole-3-acetic acid (IAA), indole-3-butyric acid (IBA), abscisic acid (ABA), gibberellic acid (GA), zeatin (Z), N(6)-benzyladenine (BA), alpha-naphthaleneacetic acid (NAA) and 2,4-dichlorophenoxyacetic acid (2,4-D) in young coconut water (CW). The analysis was carried out using a reverse-phase HPLC gradient elution, with an aqueous mobile phase (containing 0.1% formic acid, pH adjusted to 3.2 with triethylamine (TEA)) modified by methanol, and solute detection made at 265 nm wavelength. The method was validated for specificity, quantification, accuracy and precision. After preconcentration of putative endogenous phytohormones in CW using C(18) solid-phase extraction (SPE) cartridges, the HPLC method was able to screen for putative endogenous phytohormones present in CW. Finally, the identities of the putative phytohormones present in CW were further confirmed using independent liquid chromatography-tandem mass spectrometry (LC-MS/MS) equipped with an electrospray ionization (ESI) interface.

  4. Quantitative determination of chromium picolinate in animal feeds by solid phase extraction and liquid chromatography-tandem mass spectrometry.

    PubMed

    Han, Miaomiao; Tian, Ying; Li, Zhen; Chen, Yiqiang; Yang, Wenjun; Zhang, Liying

    2017-12-01

    Chromium picolinate is one of the important Cr 3+ resources and is widely used in animal production. A convenient, reliable and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantitative determination of chromium picolinate in animal feeds. Feed samples were extracted with acetonitrile and subsequently cleaned up by solid phase extraction cartridges Supelclean™ LC-18. Chromium picolinate was efficiently separated with a Waters ACQUITY UPLC ® BEH C18 column, ionized with electrospray ion source in positive mode (ESI + ), and quantitatively determined by tandem mass spectrometry in multiple reaction monitoring mode. Standard calibration curve of chromium picolinate in the concentration range from 0.5 to 1000ng/mL was obtained with good linearity correlation coefficient (R 2 =0.9982). Average recoveries ranged from 95.37%∼105.54%, as detected by spiking 0.02∼640mg/kg of chromium picolinate in complete feed, concentrated feed and premix. Intra-day and inter-day coefficient of variation were 0.59%∼6.67% and 2.36%∼6.97%, respectively. The limits of quantitation were 0.02mg/kg, 0.025mg/kg, and 2mg/kg for complete feed, concentrated feed, and premix, respectively. Actual sample analysis indicated that the developed method can be an effective tool to monitoring CrPic content in animal feed. Copyright © 2017. Published by Elsevier B.V.

  5. Liquid Metering Centrifuge Sticks (LMCS): A Centrifugal Approach to Metering Known Sample Volumes for Colorimetric Solid Phase Extraction (C-SPE)

    NASA Technical Reports Server (NTRS)

    Gazda, Daniel B.; Schultz, John R.; Clarke, Mark S.

    2007-01-01

    Phase separation is one of the most significant obstacles encountered during the development of analytical methods for water quality monitoring in spacecraft environments. Removing air bubbles from water samples prior to analysis is a routine task on earth; however, in the absence of gravity, this routine task becomes extremely difficult. This paper details the development and initial ground testing of liquid metering centrifuge sticks (LMCS), devices designed to collect and meter a known volume of bubble-free water in microgravity. The LMCS uses centrifugal force to eliminate entrapped air and reproducibly meter liquid sample volumes for analysis with Colorimetric Solid Phase Extraction (C-SPE). C-SPE is a sorption-spectrophotometric platform that is being developed as a potential spacecraft water quality monitoring system. C-SPE utilizes solid phase extraction membranes impregnated with analyte-specific colorimetric reagents to concentrate and complex target analytes in spacecraft water samples. The mass of analyte extracted from the water sample is determined using diffuse reflectance (DR) data collected from the membrane surface and an analyte-specific calibration curve. The analyte concentration can then be calculated from the mass of extracted analyte and the volume of the sample analyzed. Previous flight experiments conducted in microgravity conditions aboard the NASA KC-135 aircraft demonstrated that the inability to collect and meter a known volume of water using a syringe was a limiting factor in the accuracy of C-SPE measurements. Herein, results obtained from ground based C-SPE experiments using ionic silver as a test analyte and either the LMCS or syringes for sample metering are compared to evaluate the performance of the LMCS. These results indicate very good agreement between the two sample metering methods and clearly illustrate the potential of utilizing centrifugal forces to achieve phase separation and metering of water samples in microgravity.

  6. Synthesis of metronidazole-imprinted molecularly imprinted polymers by distillation precipitation polymerization and their use as a solid-phase adsorbent and chromatographic filler.

    PubMed

    Liu, Jiang; Zhang, Lu; Li Han Song, Le; Liu, Yuan; Tang, Hui; Li, Yingchun

    2015-04-01

    Metronidazole-imprinted polymers with superior recognition properties were prepared by a novel strategy called distillation-precipitation polymerization. The as-obtained polymers were characterized by Fourier-transform infrared spectroscopy, laser particle size determination and scanning electron microscopy, and their binding performances were evaluated in detail by static, kinetic and dynamic rebinding tests, and Scatchard analysis. The results showed that when the fraction of the monomers was 5 vol% in the whole reaction system, the prepared polymers afforded good morphology, monodispersity, and high adsorption capacity and excellent selectivity to the target molecule, metronidazole. The optimal binding performance is 12.41 mg/g for metronidazole just before leakage occurred and 38.51 mg/g at saturation in dynamic rebinding tests. Metronidazole-imprinted polymers were further applied as packing agents in solid-phase extraction and as chromatographic filler, both of which served for the detection of metronidazole in fish tissue. The results illustrated the recoveries of spiked samples ranged from 82.97 to 87.83% by using molecularly imprinted solid-phase extraction combined with a C18 commercial column and 93.7 to 101.2% by directly using the polymer-packed chromatographic column. The relative standard deviation of both methods was less than 6%. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Simultaneous determination of celecoxib, hydroxycelecoxib, and carboxycelecoxib in human plasma using gradient reversed-phase liquid chromatography with ultraviolet absorbance detection.

    PubMed

    Störmer, Elke; Bauer, Steffen; Kirchheiner, Julia; Brockmöller, Jürgen; Roots, Ivar

    2003-01-05

    A new HPLC method for the simultaneous determination of celecoxib, carboxycelecoxib and hydroxycelecoxib in human plasma samples has been developed. Following a solid-phase extraction procedure, the samples were separated by gradient reversed-phase HLPC (C(18)) and quantified using UV detection at 254 nm. The method was linear over the concentration range 10-500 ng/ml. The intra-assay variability for the three analytes ranged from 4.0 to 12.6% and the inter-assay variability from 4.9 to 14.2%. The achieved limits of quantitation (LOQ) of 10 ng/ml for each analyte allowed the determination of the pharmacokinetic parameters of the analytes after administration of 100 mg celecoxib.

  8. Magnetic porous carbon derived from a metal-organic framework as a magnetic solid-phase extraction adsorbent for the extraction of sex hormones from water and human urine.

    PubMed

    Ma, Ruiyang; Hao, Lin; Wang, Junmin; Wang, Chun; Wu, Qiuhua; Wang, Zhi

    2016-09-01

    An iron-embedded porous carbon material (MIL-53-C) was fabricated by the direct carbonization of MIL-53. The MIL-53-C possesses a high surface area and good magnetic behavior. The structure, morphology, magnetic property, and porosity of the MIL-53-C were studied by scanning electron microscopy, transmission electron microscopy, vibrating sample magnetometry, and N2 adsorption. With the use of MIL-53-C as the magnetic solid-phase extraction adsorbent, a simple and efficient method was developed for the magnetic solid-phase extraction of three hormones from water and human urine samples before high-performance liquid chromatography with UV detection. The developed method exhibits a good linear response in the range of 0.02-100 ng/mL for water and 0.5-100 ng/mL for human urine samples, respectively. The limit of detection (S/N = 3) for the analytes was 0.005-0.01 ng/mL for water sample and 0.1-0.3 ng/mL for human urine sample. The limit of quantification (S/N = 10) of the analytes were in the range of 0.015-0.030 and 0.3-0.9 ng/mL, respectively. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Preparation of C18 composite solid-phase microextraction fiber and its application to the determination of organochlorine pesticides in water samples.

    PubMed

    Li, Siyan; Lu, Chengwei; Zhu, Fang; Jiang, Ruifen; Ouyang, Gangfeng

    2015-05-11

    In this work, a C18 composite solid-phase microextraction (SPME) fiber was prepared with a new method and applied to the analysis of organochlorine pesticides (OCPs) in water sample. A stainless steel wire (o.d. 127 μm) was used as the substrate, and a mixture of the C18 particle (3.5 μm) and the 184 silicone was used as the coating material. During the process of fiber preparation, a section of capillary column was used to fix the mixture onto the stainless steel wire and to ensure the constant of coating thickness. The prepared fiber showed excellent thermal stability and solvent resistance. By coupling with gas chromatography-mass spectrometry (GC-MS), the fiber exhibited wide linearity (2-500 ng L(-1)) and good sensitivity for the determination of six OCPs in water samples, the OCPs tested included hexachlorobezene, trans-chlordane, cis-chlordane, o,p-DDT, p,p-DDT and mirex. Not only the extraction performance of the newly prepared fiber was more than seven times higher than those of commercial fibers, the limits of detections (LODs) (0.059-0.151 ng L(-1)) for OCPs achieved under optimized conditions were also lower than those of reported SPME methods. The fiber was successfully applied to the determination of OCPs in real water samples by using developed SPME-GC-MS method. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Determination of metolcarb and diethofencarb in apples and apple juice by solid-phase microextraction-high performance liquid chromatography.

    PubMed

    Yang, Xiu-Min; Wang, Ou; Wang, Ming-Zhao; Hu, Yan-Xue; Li, Wei-Ning; Wang, Zhi

    2008-09-01

    A method for the determination of metolcarb and diethofencarb in apples and apple juice is developed using solid-phase microextraction (SPME) coupled with high-performance liquid chromatography (HPLC). The experimental conditions of SPME, such as the kind of extraction fiber, extraction time, stirring rate, pH of the extracting solution, and desorption conditions are optimized. The SPME is performed on a 60 microm polydimethylsiloxane/divinylbenzene fiber for 40 min at room temperature with the solution being stirred at 1100 rpm. The extracted pesticides on the SPME fiber are desorbed in the mobile phase into SPME-HPLC interface for HPLC analysis. Separations are carried out on a Baseline C18 column (4.6 i.d. x 250 mm, 5.0 microm) with acetonitrile-water (55/45, v/v) as the mobile phase at a flow rate of 1.0 mL/min, and photodiode-array detection at 210 nm. For apple samples, the method is linear for both metolcarb and diethofencarb in the range of 0.05-1.0 mg/kg (r > 0.99), with a detection limit (S/N = 3 ) of 15 and 5 microg/kg, respectively. For apple juice, the method is linear for both metholcarb and diethofencarb over the range of 0.05-1.0 mg/L (r > 0.99) with the detection limit (S/N = 3 ) of 15 and 3 microg/L, respectively. Excellent recovery and reproducibility values are achieved. The proposed method is shown to be simple, sensitive, and organic solvent-free, and is suitable for the determination of the two pesticides in apples and apple juice.

  11. [Separation and purification of the components in Trachelospermum jasminoides by two dimensional hydrophilic interaction liquid chromatography- reversed-phase liquid chromatography].

    PubMed

    Jia, Youmei; Cai, Jianfeng; Xin, Huaxia; Feng, Jiatao; Fu, Yanhui; Fu, Qing; Jin, Yu

    2017-06-08

    A preparative two dimensional hydrophilic interaction liquid chromatography/reversed-phase liquid chromatography (Pre-2D-HILIC/RPLC) method was established to separate and purify the components in Trachelospermum jasminoides . The pigments and strongly polar components were removed from the crude extract after the active carbon decolorization and solid phase extraction processes. A Click XIon column (250 mm×20 mm, 10 μm) was selected as stationary phase and water-acetonitrile as mobile phases in the first dimensional HILIC. Finally, 15 fractions were collected under UV-triggered mode. In the second dimensional RPLC, a C18 column (250 mm×20 mm, 5 μm) was selected and water-acetonitrile was used as mobile phases. As a result, 14 compounds with high purity were obtained, which were further identified by mass spectrometry (MS) and nuclear magnetic resonance (NMR). Finally, 11 lignan compounds and three flavonoid compounds were obtained. The method has a good orthogonality, and can improve the resolution and the peak capacity. It is significant for the separation of complex components from Trachelospermum jasminoides .

  12. Development of an analytical procedure to study linear alkylbenzenesulphonate (LAS) degradation in sewage sludge-amended soils.

    PubMed

    Comellas, L; Portillo, J L; Vaquero, M T

    1993-12-24

    A procedure for determining linear alkylbenzenesulphonates (LASs) in sewage sludge and amended soils has been developed. Extraction by sample treatment with 0.5 M potassium hydroxide in methanol and reflux was compared with a previously described extraction procedure in Soxhlet with methanol and solid sodium hydroxide in the sample. Repeatability results were similar with savings in extraction time, solvents and evaporation time. A clean-up method involving a C18 cartridge has been developed. Analytes were quantified by a reversed-phase HPLC method with UV and fluorescence detectors. Recoveries obtained were higher than 84%. The standing procedure was applied to high doses of sewage sludge-amended soils (15%) with increasing quantities of added LASs. Degradation data for a 116-day period are presented.

  13. The use of coenzyme Q0 as a template in the development of a molecularly imprinted polymer for the selective recognition of coenzyme Q10.

    PubMed

    Contin, Mario; Flor, Sabrina; Martinefski, Manuela; Lucangioli, Silvia; Tripodi, Valeria

    2014-01-07

    In this work, a novel molecularly imprinted polymer (MIP) for use as a solid phase extraction sorbent was developed for the determination of coenzyme Q10 (CoQ10) in liver extract. CoQ10 is an essential cofactor in mitochondrial oxidative phosphorylation and a powerful antioxidant agent found in low concentrations in biological samples. This fact and its high hydrophobicity make the analysis of CoQ10 technically challenging. Accordingly, a MIP was synthesised using coenzyme Q0 as the template, methacrylic acid as the functional monomer, acetonitrile as the porogen, ethylene glycol dimethacrylate as the crosslinker and benzoyl peroxide as the initiator. Various parameters affecting the polymer preparation and extraction efficiency were evaluated. Morphological characterisation of the MIP and its proper comparison with C18 as a sorbent in solid phase extraction were performed. The optimal conditions for the molecularly imprinted solid phase extraction (MISPE) consisted of 400 μL of sample mixed with 30 mg of MIP and 600 μL of water to reach the optimum solution loading. The loading was followed by a washing step consisting of 1 mL of a 1-propanol solution (1-propanol:water, 30:70,v/v) and elution with 1 mL of 1-propanol. After clean-up, the CoQ10 in the samples was analysed by high performance liquid chromatography. The extraction recoveries were higher than 73.7% with good precision (3.6-8.3%). The limits of detection and quantification were 2.4 and 7.5 μg g(-1), respectively, and a linear range between 7.5 and 150 μg g(-1) of tissue was achieved. The new MISPE procedure provided a successful clean-up for the determination of CoQ10 in a complex matrix. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Determination of active components of Ginkgo biloba in human urine by capillary high-performance liquid chromatography/mass spectrometry with on-line column-switching purification.

    PubMed

    Ding, Shujing; Dudley, Ed; Chen, Lijuan; Plummer, Sue; Tang, Jiandong; Newton, Russell P; Brenton, A Gareth

    2006-01-01

    Ginkgo biloba is one of the most popular herbal nutritional supplements, with terpene lactones and flavonoids being the two major active components. An on-line purification high-performance liquid chromatography/mass spectrometry (HPLC/MS) method was successfully developed for the quantitative determination of flavonoids and terpene lactones excreted in human urine after ingesting the herbal supplement. Satisfactory separation was obtained using a C18 capillary column made in-house with sample clean-up and pre-concentration achieved using a C18 pre-column with column switching. High selectivity and limits of detection of 1-18 ng/mL were achieved using a selected ion monitoring (SIM) scan in negative ion mode; the on-line solid-phase extraction (SPE) recovery of the active components in Ginkgo biloba determined in this study was greater than 75%. Copyright 2006 John Wiley & Sons, Ltd.

  15. Comparison between solid phase microextraction (SPME) and hollow fiber liquid phase microextraction (HFLPME) for determination of extractables from post-consumer recycled PET into food simulants.

    PubMed

    Oliveira, Éder Costa; Echegoyen, Yolanda; Cruz, Sandra Andrea; Nerin, Cristina

    2014-09-01

    Hollow fiber liquid phase microextraction (HFLPME) and solid phase microextraction (SPME) methods for pre-concentration of contaminants (toluene, benzophenone, tetracosane and chloroform) in food simulants were investigated. For HFLPME 1-heptanol, 2-octanone and dibutyl-ether were studied as extracting solvents. Analysis by gas chromatography coupled to mass spectrometry (GC-MS), flame ionization (GC-FID) and electron capture detectors (GC-ECD) were carried out. In addition, the methods were employed to evaluate the safety in use of a PET material after the recycling process (comprising washing, extrusion and solid state polymerization (SSP)) through extractability studies of the contaminants using 10% (v/v) ethanol in deionized water and 3% (w/v) acetic acid in deionized water as food simulants in different conditions: 10 days at 40°C and 2h at 70°C. The HFLPME preconcentration method provided increased sensitivity when compared to the SPME method and allowed to analyze concentration levels below 10 µg surrogate per kg food simulant. The results of the extractability studies showed considerable reductions after the extrusion and SSP processes and indicated the compliance with regulations for using recycled PET in contact with food. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Trace analysis of endocrine disrupting compounds in environmental water samples by use of solid-phase extraction and gas chromatography with mass spectrometry detection.

    PubMed

    Azzouz, Abdelmonaim; Ballesteros, Evaristo

    2014-09-19

    A novel analytical method using a continuous solid-phase extraction system in combination with gas chromatography-mass spectrometry for the simultaneous separation and determination of endocrine disrupting compounds (EDCs) is reported. The method was applied to major EDCs of various types including parabens, alkylphenols, phenylphenols, bisphenol A and triclosan in water. Samples were preconcentrated by using an automatic solid-phase extraction module containing a sorbent column, and retained analytes eluted with acetonitrile for derivatization with a mixture of N,O-bis(trimethylsilyl)trifluoroacetamide and trimethylchlorosilane. A number of variables potentially influencing recovery of the target compounds such as the type of SPE sorbent (Silica gel, Florisil, RP-C18, Amberlite XAD-2 and XAD-4, Oasis HLB and LiChrolut EN), eluent and properties of the water including pH and ionic strength, were examined. LiChrolut EN was found to be the most efficient sorbent for retaining the analytes, with ∼100% efficiency. The ensuing method was validated with good analytical results including low limits of detection (0.01-0.08ng/L for 100mL of sample) and good linearity (r(2)>0.997) throughout the studied concentration ranges. The method exhibited good accuracy (recoveries of 90-101%) and precision (relative standard deviations less than 7%) in the determination of EDCs in drinking, river, pond, well, swimming pool and waste water. Waste water samples were found to contain the largest number and highest concentrations of analytes (3.2-390ng/L). Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Analysis of 19-nortestosterone residue in animal tissues by ion-trap gas chromatography-tandem mass spectrometry*

    PubMed Central

    Jiang, Jin-qing; Zhang, Lei; Li, Guang-ling; Zhang, Hai-tang; Yang, Xue-feng; Liu, Jun-wei; Li, Ren-feng; Wang, Zi-liang; Wang, Jian-hua

    2011-01-01

    A rapid sample treatment procedure for the gas chromatography-tandem mass spectrometry (GC-MS) determination of 19-nortestosterone (19-NT) in animal tissues has been developed. In our optimized procedures, enzymatic hydrolysis with β-glucuronidase from Escherichia coli was performed in an acetate buffer (pH 5.2, 0.2 mol/L). Next, the homogenate was mixed with methanol and heated at 60 °C for 15 min, then placed in an ice-bath at −18 °C for 2 h. After liquid-liquid extraction with n-hexane, the analytes were subjected to a normal-phase solid phase extraction (SPE) C18 cartridge for clean-up. The dried organic extracts were derivatized with heptafluorobutyric anhydride (HFBA), and then the products were injected into GC-MS. Using electron impact mass spectrometry (EI-MS) with positive chemical ionization (PCI), four diagnostic ions (m/z 666, 453, 318, and 306) were determined. A standard calibration curve over the concentration range of 1–20 ng/g was reached, with Y=467 084X−68 354 (R 2=0.999 7) for 19-NT, and the detection limit was 0.3 ng. When applied to spiked samples collected from bovine and ovine, the recoveries ranged from 63% to 101% with relative standard deviation (RSD) between 2.7% and 8.9%. The procedure is a highly efficient, sensitive, and more economical method which offers considerable potential to resolve cases of suspected nandrolone doping in husbandry animals. PMID:21634039

  18. [Simultaneous determination of canthaxanthin and astaxanthin in feedstuffs using solid phase extraction-reversed-phase high performance liquid chromatography].

    PubMed

    Zhang, Hua; Yang, Xin; Ma, Ying; Dong, Aijun; Zhang, Yingchun

    2008-05-01

    A method was developed for the simultaneous determination of canthaxanthin and astaxanthin in feedstuffs using reversed-phase high performance liquid chromatography (RP-HPLC). The sample was extracted by acetonitrile, and cleaned up by an LC-NH2 column. An Agilent ZORBAX Eclipse XDB-C18 analytical column (150 mm x 4.6 mm, 5 microm) was used and kept at 25 degrees C. Acetonitrile-methanol (95 : 5, v/v) was used as the mobile phase at a flow rate of 1.0 mL/min. The detection was performed by a diode array detector at 474 nm. The quantitive analysis of external standard calibration curves was used. The linear ranges of the method for canthaxanthin and astaxanthin were 1.0 - 30.0 mg/L (r = 0.999 0) and 1.0 - 20.0 mg/L (r = 0.999 1), respectively. The average recoveries were 90% - 101% with the relative standard deviations of 0.62% - 3.68%. The detection limits were 0.84 and 0.60 mg/L for canthaxanthin and astaxanthin, respectively. The method is simple, precise, sensitive and reproductive. It can be used to determine the contents of canthaxanthin and astaxanthin in feedstuffs.

  19. Rapid mixed mode solid phase extraction method for the determination of acrylamide in roasted coffee by HPLC-MS/MS.

    PubMed

    Bortolomeazzi, Renzo; Munari, Marina; Anese, Monica; Verardo, Giancarlo

    2012-12-15

    In this work, a rapid and reliable purification method based on a single mixed solid phase extraction (SPE) column, for the determination of acrylamide in roasted coffee by liquid chromatography-tandem mass spectrometry, was developed. Deuterium labelled d(3)-acrylamide was used as internal standard. Acrylamide was extracted by 10 mL of water and the extract purified by a single SPE column consisting of 0.5 g of an in-house prepared mixture of C18, strong cation (SCX) and anion exchange (SAX) sorbents in the ratio 2/1.5/1.5 (w/w/w). The amount of the three sorbents was optimised in order to eliminate the main interfering compounds present in coffee extracts, such as melanoidins, trigonelline, chlorogenic acids and caffeine. The SPE procedure was very simple and consisted of pushing 1 mL of an aqueous coffee extract through the SPE column followed by 1 mL of water which was collected for the analysis. The method was tested on six samples of roasted coffee of different composition and roasting level. The repeatability of the method, expressed as relative standard deviation (n=6), was lower than 5%. The recovery of acrylamide at three spiked levels ranged from 92% to 95%. The limits of detection (LOD) and quantitation (LOQ) were 5 and 16 μg kg(-1), respectively. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. A simplified radiometabolite analysis procedure for PET radioligands using a solid phase extraction with micellar medium.

    PubMed

    Nakao, Ryuji; Halldin, Christer

    2013-07-01

    A solid phase extraction method has been developed for simple and high-speed direct determination of PET radioligands in plasma. This methodology makes use of a micellar medium and a solid-phase extraction cartridge for displacement of plasma protein bound radioligand and separation of PET radioligands from their radiometabolites without significant preparation. The plasma samples taken from monkey or human during PET measurements were mixed with a micellar eluent containing an anionic surfactant sodium dodecyl sulphate and loaded onto SPE cartridges. The amount of radioactivity corresponding to parent radioligand (retained on the cartridge) and its radioactive metabolites (eluted with micellar eluent) was measured. Under the optimized conditions, excellent separation of target PET radioligands from their radiometabolites was achieved with a single elution and short run-time of 1 min. This method was successfully applied to study the metabolism for (11)C-labelled radioligands in human or monkey plasma. The amount of parent PET radioligands estimated by micellar solid phase extraction strongly corresponded with that determined by radio-LC. The improved throughput permitted the analysis of a large number of plasma samples (up to 13 samples per one PET study) for accurate estimation of metabolite-corrected input function during quantitative PET imaging studies. Solid phase extraction together with micellar medium is fast, sensitive and easy to use, and therefore it is an attractive alternative method to determine relative composition of PET radioligands in plasma. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Determination of some aldehydes by using solid-phase microextraction and high-performance liquid chromatography with UV detection.

    PubMed

    Kumar, Ashwini; Singh, Baldev; Malik, Ashok Kumar; Tiwary, Dhananjay K

    2007-01-01

    A new approach has been developed for the extraction and determination of aldehydes such as veratraldehyde, m-nitrobenzaldehyde, cinnamaldehyde, benzaldehyde, and p-chlorobenzaldehyde by using solid-phase microextraction (SPME) and high-performance liquid chromatography with UV detection (HPLC/UV). The method involves adsorption of the aldehydes on polydimethylsiloxane/divinylbenzene-coated fiber, followed by desorption in the desorption chamber of the SPME-HPLC interface, using acetonitrile-water (70 + 30) as the mobile phase; UV detection was at 254 nm. A good separation of 5 aldehydes was obtained on a C18 column. The detection limits of veratraldehyde, m-nitrobenzaldehyde, cinnamaldehyde, benzaldehyde, and p-chlorobenzaldehyde are 25, 41, 13, 12, and 11 pg/mL, respectively, which are about 100 times better than the detection limits for other SPME methods using gas chromatography. The proposed method was validated by determining benzaldehyde in bitter almonds and cinnamaldehyde in cinnamon bark. The recoveries of the 5 analytes were determined by analysis of spiked drinking water.

  2. Determination of 18 beta-glycyrrhetinic acid in biological fluids from humans and rats by solid-phase extraction and high-performance liquid chromatography.

    PubMed

    Hasler, F; Krapf, R; Brenneisen, R; Bourquin, D; Krähenbühl, S

    1993-10-22

    Methods have been developed and characterized allowing rapid isolation and quantification of 18 beta-glycyrrhetinic acid (GRA) in biological fluids from both humans and rats. Sample preparation includes extraction with urea-methanol for plasma samples, and solid-phase extraction (SPE) for urine and bile samples. Hydrolysis of GRA glucuronides in urine and bile was performed by treatment with beta-glucuronidase. MGRA, the 3-O-methyl derivative of GRA was synthesized as an internal standard resistant to hydrolysis. High-performance liquid chromatography (HPLC) was performed with an isocratic system using methanol-water-acetic acid (83:16.8:0.2, v/v/v) as solvent on a Lichrocart RP-18 column at 30 degrees C with ultraviolet detection. The methods allowed base line separation of GRA and MGRA from all biological fluids tested, with a detection limit of 0.15 mg/l. Validation of the methods included determination of recovery, accuracy and precision in plasma, bile and urine from humans and rats. The methods were further evaluated by investigating the pharmacokinetics of GRA in normal rats and in rats with a bile fistula. Following an intravenous dose of 10 mg/kg, the plasma concentration-time curve of GRA could be fitted to a one compartment model both in control and bile fistula rats. The elimination half life averaged 15.0 +/- 2.2 versus 16.8 +/- 2.4 min in control and bile fistula rats (difference not significant). Within 90 min following administration of GRA, urinary elimination of GRA and GRA glucuronides was less than 1% in both groups whereas biliary elimination averaged 51.3 +/- 3.1%. The results show that the methods developed allow pharmacokinetic studies of GRA in humans and rats.

  3. Critical evaluation and comparison of enrichment efficiency of multi-walled carbon nanotubes, C18 silica and activated carbon towards some pesticides from environmental waters.

    PubMed

    El-Sheikh, Amjad H; Sweileh, Jamal A; Al-Degs, Yahya S; Insisi, Ahmad A; Al-Rabady, Nancy

    2008-02-15

    In this work, optimization of multi-residue solid phase extraction (SPE) procedures coupled with high-performance liquid chromatography for the determination of Propoxur, Atrazine and Methidathion from environmental waters is reported. Three different sorbents were used in this work: multi-walled carbon nanotubes (MWCNTs), C18 silica and activated carbon (AC). The three optimized SPE procedures were compared in terms of analytical performance, application to environmental waters, cartridge re-use, adsorption capacity and cost of adsorbent. Although the adsorption capacity of MWCNT was larger than AC and C18, however, the analytical performance of AC could be made close to the other sorbents by appropriate optimization of the SPE procedures. A sample of AC was then oxidized with various oxidizing agents to show that ACs of various surface properties has different enrichment efficiencies. Thus researchers are advised to try AC of various surface properties in SPE of pollutants prior to using expensive sorbents (such as MWCNT and C18 silica).

  4. Attractive design: an elution solvent optimization platform for magnetic-bead-based fractionation using digital microfluidics and design of experiments.

    PubMed

    Lafrenière, Nelson M; Mudrik, Jared M; Ng, Alphonsus H C; Seale, Brendon; Spooner, Neil; Wheeler, Aaron R

    2015-04-07

    There is great interest in the development of integrated tools allowing for miniaturized sample processing, including solid phase extraction (SPE). We introduce a new format for microfluidic SPE relying on C18-functionalized magnetic beads that can be manipulated in droplets in a digital microfluidic platform. This format provides the opportunity to tune the amount (and potentially the type) of stationary phase on-the-fly, and allows the removal of beads after the extraction (to enable other operations in same device-space), maintaining device reconfigurability. Using the new method, we employed a design of experiments (DOE) operation to enable automated on-chip optimization of elution solvent composition for reversed phase SPE of a model system. Further, conditions were selected to enable on-chip fractionation of multiple analytes. Finally, the method was demonstrated to be useful for online cleanup of extracts from dried blood spot (DBS) samples. We anticipate this combination of features will prove useful for separating a wide range of analytes, from small molecules to peptides, from complex matrices.

  5. Pungency Quantitation of Hot Pepper Sauces Using HPLC

    NASA Astrophysics Data System (ADS)

    Betts, Thomas A.

    1999-02-01

    A class of compounds known as capsaicinoids are responsible for the "heat" of hot peppers. To determine the pungency of a particular pepper or pepper product, one may quantify the capsaicinoids and relate those concentrations to the perceived heat. The format of the laboratory described here allows students to collectively develop an HPLC method for the quantitation of the two predominant capsaicinoids (capsaicin and dihydrocapsaicin) in hot-pepper products. Each small group of students investigated one of the following aspects of the method: detector wavelength, mobile-phase composition, extraction of capsaicinoids, calibration, and quantitation. The format of the lab forced students to communicate and cooperate to develop this method. The resulting HPLC method involves extraction with acetonitrile followed by solid-phase extraction clean-up, an isocratic 80:20 methanol-water mobile phase, a 4.6 mm by 25 cm C-18 column, and UV absorbance detection at 284 nm. The method developed by the students was then applied to the quantitation of capsaicinoids in a variety of hot pepper sauces. Editor's Note on Hazards in our April 2000 issue addresses the above.

  6. Organochlorine pesticide contamination of ground water in the city of Hyderabad.

    PubMed

    Shukla, Gangesh; Kumar, Anoop; Bhanti, Mayank; Joseph, P E; Taneja, Ajay

    2006-02-01

    Organochlorine pesticides are ubiquitous and persistent organic pollutants used widely throughout the world. Due to the extensive use in agriculture, organic environmental contaminants such as HCH, DDT along with other organochlorine pesticides are distributed globally by transport through air and water. The main aim of present study is to determine contamination levels of organochlorine pesticides in the ground water of Hyderabad City. Water samples were collected from 28 domestic well supplies of the city. For this study, random sampling technique was applied, all the samples were collected in high purity glass bottles and refrigerated at 4 degrees C until analysis. Solid Phase Extraction (SPE) is used for the extraction of organochlorine pesticide residues in water sample. The collected water samples were pre-filtered through a 0.45 microg glass fiber filter (Wattman GF/F) to remove particulate matter and were acidified with hydrochloric acid (6N) to pH 2.5. Methanol modifier (BDH, for pesticide residue analysis, 10 mL) was added to water sample for better extraction. SPE using pre-packed reversed phase octadecyl (C-18 bonded silica) contained in cartridges was used for sample preparation. Prior to the extraction, the C-18 bonded phase, which contains 500 mg of bonded phase, was washed with 20 mL methanol. The sample was mixed well and allowed to percolate through the cartridges with flow rate of 10-15 mL/min under vacuum. After sample extraction, suction continued for 15 min to dry the packing material and pesticides trapped in the C-18 bonded phases were eluted by passing 10 mL hexane and fraction was evaporated in a gentle steam of Nitrogen. In all samples pesticide residues were analyzed by GC (Chemito-8510) with Ni63 ECD detector. Helium was used as carrier gas and nitrogen was used as make up gas. The injection technique was split/split less. All the samples analyzed were found to be contaminated with four pesticides i.e. DDT, beta-Endosulfan, alpha-Endosulfan and Lindane. DDT was found to range between 0.15 and 0.19 microg L(-1), beta-Endosulfan ranges between 0.21 and 0.87 microg L(-1), alpha-Endosulfan ranges between 1.34 and 2.14 microg L(-1) and Lindane ranges between 0.68 and 1.38 microg L(-1) respectively. These concentrations of pesticides in the water samples were found to be above their respective Acceptable Daily Intake (ADI) values for Humans.

  7. Synthesis of g-C3N4/Fe3O4 nanocomposites and application as a new sorbent for solid phase extraction of polycyclic aromatic hydrocarbons in water samples.

    PubMed

    Wang, Man; Cui, Shihai; Yang, Xiaodi; Bi, Wentao

    2015-01-01

    An easy preparation of g-C3N4/Fe3O4 nanocomposites by chemical co-precipitation has been demonstrated. The as-prepared materials were characterized by X-ray diffraction, transmission electron microscopy, Fourier transform infrared spectroscopy and thermogravimetric analysis. The high affinity of g-C3N4 toward polycyclic aromatic hydrocarbons and the magnetic behavior of Fe3O4 were combined to provide an efficient and simple magnetic solid phase extraction (MSPE). The adsorption and desorption of polycyclic aromatic hydrocarbons on g-C3N4/Fe3O4 were examined. Different factors affecting the magnetic solid phase extraction of polycyclic aromatic hydrocarbons were assessed in terms of adsorption, desorption, and recovery. Under the optimized conditions, the proposed method showed good limits of detection (LOD, S/N=3) in the range of 0.05-0.1 ng mL(-1) and precision in the range of 1.8-5.3% (RSDs, n=3). This method was also successfully applied to the analysis of real water samples; good spiked recoveries over the range of 80.0-99.8% were obtained. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. COMPARISONS OF SOXHLET EXTRACTION, PRESSURIZED LIQUID EXTRACTION, SUPERCRITICAL FLUID EXTRACTION, AND SUBCRITICAL WATER EXTRACTION FOR ENVIRONMENTAL SOLIDS: RECOVERY, SELECTIVITY, AND EFFECTS ON SAMPLE MATRIX. (R825394)

    EPA Science Inventory

    Extractions of a polycyclic aromatic hydrocarbon (PAH)-contaminated soil from a former manufactured gas plant site were performed with a Soxhlet apparatus (18 h), by pressurized liquid extraction (PLE) (50 min at 100°C), supercritical fluid extraction (SFE) (1 h at 150°...

  9. Methods of analysis by the U. S. Geological Survey National Water Quality Laboratory - determination of organonitrogen herbicides in water by solid-phase extraction and capillary-column gas chromatography/mass spectrometry with selected-ion monitoring

    USGS Publications Warehouse

    Sandstrom, Mark W.; Wydoski, Duane S.; Schroeder, Michael P.; Zamboni, Jana L.; Foreman, William T.

    1992-01-01

    A method for the isolation of organonitrogen herbicides from natural water samples using solid-phase extraction and analysis by capillary-column gas chromatography/mass spectrometry with selected-ion monitoring is described. Water samples are filtered to remove suspended particulate matter and then are pumped through disposable solid-phase extraction cartridges containing octadecyl-bonded porous silica to remove the herbicides. The cartridges are dried using carbon dioxide, and adsorbed herbicides are removed from the cartridges by elution with 1.8 milliliters of hexaneisopropanol (3:1). Extracts of the eluants are analyzed by capillary-column gas chromatography/mass spectrometry with selected-ion monitoring of at least three characteristic ions. The method detection limits are dependent on sample matrix and each particular herbicide. The method detection limits, based on a 100-milliliter sample size, range from 0.02 to 0.25 microgram per liter. Recoveries averaged 80 to 115 percent for the 23 herbicides and 2 metabolites in 1 reagent-water and 2 natural-water samples fortified at levels of 0.2 and 2.0 micrograms per liter.

  10. Cork as a new (green) coating for solid-phase microextraction: determination of polycyclic aromatic hydrocarbons in water samples by gas chromatography-mass spectrometry.

    PubMed

    Dias, Adriana Neves; Simão, Vanessa; Merib, Josias; Carasek, Eduardo

    2013-04-15

    A new fiber for solid-phase microextraction (SPME) was prepared employing cork as a coating. The morphology and composition of the cork fiber was evaluated by scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FTIR), respectively. The proposed fiber was used for the determination of polycyclic aromatic hydrocarbons (PAHs) in river water samples by gas chromatography-selected ion monitoring-mass spectrometry (GC-SIM-MS). A central composite design was used for optimization of the variables involved in the extraction of PAHs from water samples. The optimal extraction conditions were extraction time and temperature of 60 min and 80°C, respectively. The detection and quantification limits were 0.03 and 0.1 μg L(-1), respectively. The recovery values were between 70.2 and 103.2% and the RSD was ≤15.7 (n=3). The linear range was 0.1-10 μg L(-1) with r≥0.96 and the fiber-to-fiber reproducibility showed RSD≤18.6% (n=5). The efficiency of the cork fiber was compared with commercially available fibers and good results were achieved, demonstrating the applicability and great potential of cork as a coating for SPME. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Determination of wear metals in engine oil by mild acid digestion and energy dispersive X-ray fluorescence spectrometry using solid phase extraction disks.

    PubMed

    Yang, Zheng; Hou, Xiandeng; Jones, Bradley T

    2003-03-10

    A simple, particle size-independent spectrometric method has been developed for the multi-element determination of wear metals in used engine oil. A small aliquot (0.5 ml) of an acid-digested oil sample is spotted onto a C-18 solid phase extraction disk to form a uniform thin film. The dried disk is then analyzed directly by energy dispersive X-ray fluorescence spectrometry. This technique provides a homogeneous and reproducible sample surface to the instrument, thus overcoming the typical problems associated with uneven particle size distribution and sedimentation. As a result, the method provides higher precision and accuracy than conventional methods. Furthermore, the disk sample may be stored and re-analyzed or extracted at a later date. The signals arising from the spotted disks, and the calibration curves constructed from them, are stable for at least 2 months. The limits of detection for Fe, Cu, Zn, Pb, and Cr are 5, 1, 4, 2, and 4 microg g(-1), respectively. Recoveries of these elements from spiked oil samples range from 92 to 110%. The analysis of two standard reference materials and a used oil sample produced results comparable to those found by inductively coupled plasma atomic emission spectrometry.

  12. Comparison of Three Solid Phase Materials for the Extraction of Carboxylic Acids from River Water Followed by 2D GC × GC-TOFMS Determination

    PubMed Central

    Bosire, G. O.; Ngila, J. C.; Parshotam, H.

    2016-01-01

    The extraction and determination of aliphatic and aromatic carboxylic acids as well as their influence on the aromaticity and molecularity relationship of natural organic matter (NOM) in water are reported in this study. Three solid phase extraction (SPE) sorbents were used and their extraction efficiencies evaluated after chromatographic determinations (using gas chromatography with a time of flight mass spectrometer (GC × GC-TOFMS) and liquid chromatography with organic carbon detector (LC-OCD)). More than 42 carboxylic acids were identified in raw water from the Vaal River, which feeds the Lethabo Power Generation Station, South Africa, with cooling water. The aromatic carboxylic acid efficiency (28%) was achieved by using Strata™ X SPE while the highest aliphatic carboxylic acid efficiency (92.08%) was achieved by silica SPE. The hydrophobic nature of NOM in water depends on the nature of organic compounds in water, whether aromatic or aliphatic. The LC-OCD was used to assess the hydrophobicity levels of NOM as a function of these carboxylic acids in cooling water. The LC-OCD results showed that the aromatic nature of NOM in SPE filtered water followed the order Silica>Strata X>C-18. From the results, the hydrophobicity degree of the samples depended on the type and number of carboxylic acids that were removed by the SPE cartridges. PMID:27274730

  13. Modafinil in Forensic and Clinical Toxicology-Case Reports, Analytics and Literature.

    PubMed

    Radünz, Lars; Reuter, Hannah; Andresen-Streichert, Hilke

    2018-06-01

    Modafinil is used because of its wakefulness-promoting properties for treatment of diseases associated with extreme sleepiness (i.e., narcolepsy). Additionally, it is misused as a "cognitive enhancer" to increase alertness and to improve concentration. We present modafinil concentrations in serum samples in five cases of our routine work measured by high-performance liquid chromatography coupled with a photo diode array detector after solid-phase extraction. One sample was analyzed for clinical toxicology purposes. The other four were investigated for the police: three cases of driving under the influence of drugs and one case of bodily harm. Sample preparation consisted of solid-phase extraction using Bond Elut® C18 columns. Papaverine was used as internal standard. Chromatographic separation was carried out using a Polaris C18-A column in an isocratic run. Wavelengths used for UV-detection were 220 nm for modafinil and 239 nm for the internal standard, respectively. The method was validated with a reduced validation design for rare analytes. A six-point-calibration from 0.5 to 5.0 mg/L, covering the therapeutic range (0.9-3.3 mg/L), was used for quantification. Concentrations in serum were in the range of 1.3 to ~34 mg/L (median: 3.6 mg/L; mean: 9.0 mg/L). To our knowledge, there are only few publications concerning the serum concentrations of modafinil in cases of (suspected) misuse, forensic cases or intoxications. In our discussion, the serum concentrations we determined are compared with the levels described in the literature so far.

  14. A sol-gel based solid phase microextraction fiber for the analysis of aliphatic alcohols in apple juices.

    PubMed

    Farhadi, Khalil; Maleki, Ramin; Tahmasebi, Raheleh

    2010-01-01

    A new fiber based on titania-chitin sol-gel coated on a silver wire for the headspace solid phase microextraction of aliphatic alcohols from apple juice samples was developed. The influences of fiber coating composition and microextraction conditions (extraction temperature, extraction time, and ionic strength of the sample matrix) on the fiber performance were investigated. Also, the influence of temperature and time on desorption of analytes from fiber were studied. Under the optimized conditions, a porous fiber with a high extraction capacity and good thermal stability (up to 250 degrees C) was obtained. The proposed headspace solid-phase microextraction-GC method was successfully used for the analysis of aliphatic alcohols in apple juice and concentrate samples. The recovery values were from 92.8 to 98.6%. The RSD (n=5) for all analytes were below 7.8%.

  15. Automated in-tube solid-phase microextraction coupled with liquid chromatography/electrospray ionization mass spectrometry for the determination of beta-blockers and metabolites in urine and serum samples.

    PubMed

    Kataoka, H; Narimatsu, S; Lord, H L; Pawliszyn, J

    1999-10-01

    The technique of automated in-tube solid-phase microextraction (SPME) coupled with liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) was evaluated for the determination of beta-blockers in urine and serum samples. In-tube SPME is an extraction technique for organic compounds in aqueous samples, in which analytes are extracted from the sample directly into an open tubular capillary by repeated draw/eject cycles of sample solution. LC/MS analyses of beta-blockers were initially performed by liquid injection onto a LC column. Nine beta-blockers tested in this study gave very simple ESI mass spectra, and strong signals corresponding to [M + H]+ were observed for all beta-blockers. The beta-blockers were separated with a Hypersil BDS C18 column using acetonitrile/methanol/water/acetic acid (15:15:70:1) as a mobile phase. To optimize the extraction of beta-blockers, several in-tube SPME parameters were examined. The optimum extraction conditions were 15 draw/eject cycles of 30 microL of sample in 100 mM Tris-HCl (pH 8.5) at a flow rate of 100 microL/min using an Omegawax 250 capillary (Supelco, Bellefonte, PA). The beta-blockers extracted by the capillary were easily desorbed by mobile-phase flow, and carryover of beta-blockers was not observed. Using in-tube SPME/LC/ESI-MS with selected ion monitoring, the calibration curves of beta-blockers were linear in the range from 2 to 100 ng/mL with correlation coefficients above 0.9982 (n = 18) and detection limits (S/N = 3) of 0.1-1.2 ng/mL. This method was successfully applied to the analysis of biological samples without interference peaks. The recoveries of beta-blockers spiked into human urine and serum samples were above 84 and 71%, respectively. A serum sample from a patient administrated propranolol was analyzed using this method and both propranolol and its metabolites were detected.

  16. Validated LC–MS-MS Method for Multiresidual Analysis of 13 Illicit Phenethylamines in Amniotic Fluid

    PubMed Central

    Burrai, Lucia; Nieddu, Maria; Carta, Antonio; Trignano, Claudia; Sanna, Raimonda; Boatto, Gianpiero

    2016-01-01

    A multi-residue analytical method was developed for the determination in amniotic fluid (AF) of 13 illicit phenethylamines, including 12 compounds never investigated in this matrix before. Samples were subject to solid-phase extraction using; hydrophilic–lipophilic balance cartridges which gave good recoveries and low matrix effects on analysis of the extracts. The quantification was performed by liquid chromatography electrospray tandem mass spectrometry. The water–acetonitrile mobile phase containing 0.1% formic acid, used with a C18 reversed phase column, provided adequate separation, resolution and signal-to-noise ratio for the analytes and the internal standard. The final optimized method was validated according to international guidelines. A monitoring campaign to assess fetal exposure to these 13 substances of abuse has been performed on AF test samples obtained from pregnant women. All mothers (n = 194) reported no use of drugs of abuse during pregnancy, and this was confirmed by the analytical data. PMID:26755540

  17. Conventional sample enrichment strategies combined with high-performance liquid chromatography-solid phase extraction-nuclear magnetic resonance analysis allows analyte identification from a single minuscule Corydalis solida plant tuber.

    PubMed

    Sturm, Sonja; Seger, Christoph; Godejohann, Markus; Spraul, Manfred; Stuppner, Hermann

    2007-09-07

    Identification of putative biomarker molecules within the genus Corydalis (Papaveraceae) was pursued by combining conventional off-line sample enrichment with high-performance liquid chromatography-solid phase extraction-nuclear magnetic resonance (HPLC-SPE-NMR) based structure elucidation. Off-line reversed phase solid phase extraction (SPE) was used to enrich the desired analytes from a methanolic extract (93 mg dry weight) of a miniscule single tuber (233 mg dry weight) of C. solida. An aliquot of the SPE fraction (2.1 mg) was subjected to separation in the HPLC-SPE-NMR hyphenation. Chromatographic peaks bearing the metabolites under investigation were trapped in the SPE device in a single experiment and transferred to a 600 MHz NMR spectrometer equipped with a 30 microl cryofit insert fed into a 3 mm cryoprobe. Recorded homo- and heteronuclear 1D and 2D NMR data allowed the identification of the three analytes under investigation as protopine, allocryptopine, and N-methyl-laudanidinium acetate. The latter is a rare alkaloid, which has been isolated only once before.

  18. Investigation of Tank 241-AN-101 Floating Solids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kraft, Douglas P.; Meznarich, H. K.

    Tank 241-AN-101 is the receiver tank for retrieval of several C-Farms waste tanks, including Tanks 241-C-102 and 241-C-111. Tank 241 C 111 received first-cycle decontamination waste from the bismuth phosphate process and Plutonium and Uranium Extraction cladding waste, as well as hydraulic fluid. Three grab samples, 1AN-16-01, 1AN-16-01A, and 1AN-16-01B, were collected at the surface of Tank 241-AN-101 on April 25, 2016, after Tank 241-C-111 retrieval was completed. Floating solids were observed in the three grab samples in the 11A hot cell after the samples were received at the 222-S Laboratory. Routine chemical analyses, solid phase characterization on the floatingmore » and settled solids, semivolatile organic analysis mainly on the aqueous phase for identification of degradation products of hydraulic fluids were performed. Investigation of the floating solids is reported.« less

  19. Analysis of penicillin G in milk by liquid chromatography.

    PubMed

    Boison, J O; Keng, L J; MacNeil, J D

    1994-01-01

    A liquid chromatographic (LC) method that was previously developed for penicillin G residues in animal tissues has been adapted to milk and milk products. After protein precipitation with sodium tungstate, samples are applied to a C18 solid-phase extraction cartridge, from which penicillin is eluted, derivatized with 1,2,4-triazole-mercuric chloride solution, and analyzed by isocratic liquid chromatography (LC) on a C18 column with UV detection at 325 nm. Quantitation is done with reference to penicillin V as an internal standard. Penicillin G recoveries were determined to be > 70% on standards fortified at 3-60 ppb. Accuracy approached 100% using the penicillin V internal standard. The detection limit for penicillin G residues was 3 ppb in fluid milk. Samples may be confirmed by thermospray/LC at concentrations approaching the detection limit of the UV method.

  20. Simultaneously determination of bisphenol A and its alternatives in sediment by ultrasound-assisted and solid phase extractions followed by derivatization using GC-MS.

    PubMed

    Wang, Qiang; Zhu, Lingyan; Chen, Meng; Ma, Xinxin; Wang, Xiaolei; Xia, Junchao

    2017-02-01

    Bisphenol analogues are a group of chemicals which are being widely applied in industrial and household products owing to regulations on bisphenol A (BPA) in many countries. In this study, an analytical method, including extraction from complex environmental matrices, clean-up using solid phase extraction (SPE) and following-up derivatization prior to gas chromatography coupled with mass spectrometry (GC-MS), was developed to analyze seven commonly used bisphenols in sediment. Five kinds of extraction solvents, four kinds of SPE cartridges, and four kinds of SPE eluting solvents were individually tested for their performances; and the conditions for derivatizing were also optimized. Finally, C 18 cartridge was determined as the SPE cartridge and methanol was selected as extracting and eluting solvent. Acetic anhydride (AA) was used as derivatizing agent and reaction took 20 min at room temperature. The method was used successfully to measure the seven bisphenol compounds in sediment samples from Taihu Lake, China. BPA, bisphenol F and bisphenol S were detected in all sediment samples, with concentrations in the range of 3.94-33.2; 0.503-3.28 and 0.323-27.3 ng g -1 dw. Other compounds were detected at low frequencies or not detected. We provided a convenient, reliable, and sensitive method to analyze bisphenol compounds in complex environmental samples. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Liquid chromatography/electrospray ionisation-tandem mass spectrometry quantification of GM2 gangliosides in human peripheral cells and plasma.

    PubMed

    Fuller, Maria; Duplock, Stephen; Hein, Leanne K; Rigat, Brigitte A; Mahuran, Don J

    2014-08-01

    GM2 gangliosidosis is a group of inherited neurodegenerative disorders resulting primarily from the excessive accumulation of GM2 gangliosides (GM2) in neuronal cells. As biomarkers for categorising patients and monitoring the effectiveness of developing therapies are lacking for this group of disorders, we sought to develop methodology to quantify GM2 levels in more readily attainable patient samples such as plasma, leukocytes, and cultured skin fibroblasts. Following organic extraction, gangliosides were partitioned into the aqueous phase and isolated using C18 solid-phase extraction columns. Relative quantification of three species of GM2 was achieved using LC/ESI-MS/MS with d35GM1 18:1/18:0 as an internal standard. The assay was linear over the biological range, and all GM2 gangliosidosis patients were demarcated from controls by elevated GM2 in cultured skin fibroblast extracts. However, in leukocytes only some molecular species could be used for differentiation and in plasma only one was informative. A reduction in GM2 was easily detected in patient skin fibroblasts after a short treatment with media from normal cells enriched in secreted β-hexosaminidase. This method may show promise for measuring the effectiveness of experimental therapies for GM2 gangliosidosis by allowing quantification of a reduction in the primary storage burden. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Report: An ex vivo up-take of levamisole molecules by cestode (Monezia expensa) of goat (Capra hirsa) and its detection through RP-HPLC.

    PubMed

    Ayaz, Muhammad Mazhar; Sajid, Muhammad; Das, Sanjota Nirmal; Hanif, Muhammad

    2018-05-01

    Detection of various molecules of drugs remained a prime issue especially in tissues of animals, humans and in their target parasites. The cestode/tapeworms pose a dilemma because of their weird body composition and uptake pattern of nutrients and medicines especially through absorption by tegument. We selected levamisole; thought to be potent antiparasitic/ani-cestodal drug. The uptake of levamisole (LEV) through cestodeal tissues is studied through HPCL in this paper. High performance liquid chromatography technique has been utilized to know the uptake of levamisole in tissues of cestodes of Goat (Monezia expensa) in small ruminants. The drug was exposed to M. expensa by in vitro till its death or a parasite ceases its movement. The tissue/ part of proglattids of the M. expensa were homogenized with some modifications and levamisole extraction was performed with liquid phase extraction method. The evaporation of solvent was done and the residual cestodal tissues were cleaned by solid phase. After the solid phase extraction method, the recovery of drug, detection and quantification of levamisole from cestodal tissues was determined through Reverse Phase Column High Performance Liquid Chromatography (RP-HPLC). Levamisole (LEV) molecules assay was obtained on a C18 reverse-phase (20um, 6mm x 150mm) column at flow rate of 1ml/min using acetonitrile and ammonium acetate as mobile phase and UV detection was done at 254nm. The development of method of Levamisole (LEV) detection from cestodal tissues by HPLC in vitro samples has been demonstrated first time in Pakistan, which can provide the solution of parasitic control and provide in sight in to the uptake of anti cestodal drugs either against human or livestock parasites.

  3. MSPD procedure for determining buprofezin, tetradifon, vinclozolin, and bifenthrin residues in propolis by gas chromatography-mass spectrometry.

    PubMed

    dos Santos, Thaíse Fernanda Santana; Aquino, Adriano; Dórea, Haroldo Silveira; Navickiene, Sandro

    2008-03-01

    A simple and effective extraction method based on matrix solid-phase dispersion (MSPD) was developed to determine bifenthrin, buprofezin, tetradifon, and vinclozolin in propolis using gas chromatography-mass spectrometry in selected ion monitoring mode (GC-MS, SIM). Different method conditions were evaluated, for example type of solid phase (C(18), alumina, silica, and Florisil), the amount of solid phase and eluent (n-hexane, dichloromethane, dichloromethane-n-hexane (8:2 and 1:1, v/v) and dichloromethane-ethyl acetate (9:1, 8:2 and 7:3, v/v)). The best results were obtained using 0.5 g propolis, 1.0 g silica as dispersant sorbent, 1.0 g Florisil as clean-up sorbent, and dichloromethane-ethyl acetate (9:1, v/v) as eluting solvent. The method was validated by analysis of propolis samples fortified at different concentration levels (0.25 to 1.0 mg kg(-1)). Average recoveries (four replicates) ranged from 67% to 175% with relative standard deviation between 5.6% and 12.1%. Detection and quantification limits ranged from 0.05 to 0.10 mg kg(-1) and 0.15 to 0.25 mg kg(-1) propolis, respectively.

  4. Determination of perfluoroalkyl carboxylic, sulfonic, and phosphonic acids in food.

    PubMed

    Ullah, Shahid; Alsberg, Tomas; Vestergren, Robin; Berger, Urs

    2012-11-01

    A sensitive and accurate method was developed and validated for simultaneous analysis of perfluoroalkyl carboxylic acids, sulfonic acids, and phosphonic acids (PFPAs) at low picograms per gram concentrations in a variety of food matrices. The method employed extraction with acetonitrile/water and cleanup on a mixed-mode co-polymeric sorbent (C8 + quaternary amine) using solid-phase extraction. High-performance liquid chromatographic separation was achieved on a C18 column using a mobile phase gradient containing 5 mM 1-methyl piperidine for optimal chromatographic resolution of PFPAs. A quadrupole time-of-flight high-resolution mass spectrometer operating in negative ion mode was used as detector. Method detection limits were in the range of 0.002 to 0.02 ng g(-1) for all analytes. Sample preparation (extraction and cleanup) recoveries at a spiking level of 0.1 ng g(-1) to a baby food composite were in the range of 59 to 98 %. A strong matrix effect was observed in the analysis of PFPAs in food extracts, which was tentatively assigned to sorption of PFPAs to the injection vial in the solvent-based calibration standard. The method was successfully applied to a range of different food matrices including duplicate diet samples, vegetables, meat, and fish samples.

  5. Detection of singly- and doubly-charged quaternary ammonium drugs in equine urine by liquid chromatography/tandem mass spectrometry.

    PubMed

    Ho, Emmie N M; Kwok, W H; Wong, April S Y; Wan, Terence S M

    2012-01-13

    Quaternary ammonium drugs (QADs) are anticholinergic agents some of which are known to have been abused or misused in equine sports. A recent review of literature shows that the screening methods reported thus far for QADs mainly cover singly-charged QADs. Doubly-charged QADs are extremely polar substances which are difficult to be extracted and poorly retained on reversed-phase columns. It would be ideal if a comprehensive method can be developed which can detect both singly- and doubly-charged QADs. This paper describes an efficient liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the simultaneous detection and confirmation of 38 singly- and doubly-charged QADs at sub-parts-per-billion (ppb) to low-ppb levels in equine urine after solid-phase extraction. Quaternary ammonium drugs were extracted from equine urine by solid-phase extraction (SPE) using an ISOLUTE(®) CBA SPE column and analysed by LC/MS/MS in the positive electrospray ionisation mode. Separation of the 38 QADs was achieved on a polar group embedded C18 LC column with a mixture of aqueous ammonium formate (pH 3.0, 10 mM) and acetonitrile as the mobile phase. Detection and confirmation of the 38 QADs at sub-ppb to low-ppb levels in equine urine could be achieved within 16 min using selected reaction monitoring (SRM). Matrix interference of the target transitions at the expected retention times was not observed. Other method validation data, including precision and recovery, were acceptable. The method was successfully applied to the analyses of drug-administration samples. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. Analysis of tricyclic antidepressant drugs in plasma by means of solid-phase microextraction-liquid chromatography-mass spectrometry.

    PubMed

    Alves, Claudete; Santos-Neto, Alvaro J; Fernandes, Christian; Rodrigues, José C; Lanças, Fernando M

    2007-10-01

    Solid-phase microextraction coupled to liquid chromatography and mass spectrometry (SPME-LC-MS) was used to analyze tricyclic antidepressant drugs desipramine, imipramine, nortriptyline, amitriptyline, and clomipramine (internal standard) in plasma samples. SPME was performed by direct extraction on a PDMS/DVB (60 microm) coated fiber, employing a stirring rate of 1200 rpm for 30 min, pH 11.0, and temperature of 30 degrees C. Drug desorption was carried out by exposing the fiber to the liquid chromatography mobile phase for 20 min, using a labmade SPME-LC interface at 50 degrees C. The main variables experimentally influencing LC-MS response were evaluated and mathematically modeled. A rational optimization with fewer experiments was achieved using a factorial design approach. The constructed empirical models were adjusted with 96-98% of explained deviation allowing an adequate data set comprehension. The chromatographic separation was realized using an RP-18 column (150 mm x 2.1 mm, 5 microm particles) and ammonium acetate buffer (0.01 mol/l, pH 5.50) : acetonitrile (50 : 50 v/v) as mobile phase. Low detection levels were achieved with electrospray interface (0.1 ng/ml). The developed method showed specificity, linearity, precision, and limit of quantification adequate to assay tricyclic antidepressant drugs in plasma.

  7. Simplified miniaturized ultrasound-assisted matrix solid phase dispersion extraction and high performance liquid chromatographic determination of seven flavonoids in citrus fruit juice and human fluid samples: hesperetin and naringenin as biomarkers.

    PubMed

    Barfi, Behruz; Asghari, Alireza; Rajabi, Maryam; Barfi, Azadeh; Saeidi, Iman

    2013-10-11

    In the present study, for the first time, a simplified miniaturized ultrasound-assisted matrix solid-phase dispersion (SM-USA-MSPD) method with a different application for liquid matrices was developed to extract different flavonoids (hesperidin, diosmin, eriocitrin, narirutin, naringin, hesperetin and naringenin) from citrus fruit juice and human fluid samples prior to their determination using high performance liquid chromatography (HPLC). Different effective parameters were studied and under the optimum conditions (including sample volume: 150μL; solid phase: silica-based C18, 200mg; eluting solvent: methanol, 500μL; pH: 4; and sonication: 6min; at room temperature), limits of detection and limits of quantification were ranged from 23.3 to 46.8ngmL(-1) and 74.8 to 141.5ngmL(-1), respectively. Once optimized, analytical performance of the method was studied in terms of linearity (0.074-198.5μgmL(-1), r(2)>0.991), accuracy (recovery=84.6-101.5%), and precision (repeatability: intra-day precision<5.9%, and inter-day precision<7.2%). At the end, SM-USA-MSPD method was successfully applied to estimate the levels of hesperetin and naringenin in plasma and urinary excretion -after ingestion of orange, grapefruit and lime juices- and the obtained results confirmed that these compounds could be used as good biomarkers of citrus fruit juice intake. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. [Determination of 11 anabolic hormones in fish tissue by multi-function impurity adsorption solid-phase extraction-ultrafast liquid chromatography-tandem mass spectrometry].

    PubMed

    Yao, Shanshan; Zhao, Yonggang; Li, Xiaoping; Chen, Xiaohong; Jin, Micong

    2012-06-01

    A method was developed for the determination of 11 anabolic hormones (boldenone, androstenedione, nandrolone, methandrostenolone, methyltestosterone, testosterone, testosterone acetate, trenbolone, testosterone propionate, stanozolol, fluoxymesterone) in fish by multi-function impurity adsorption solid-phase extraction-ultrafast liquid chromatography-tandem mass spectrometry. After the sample was extracted by methanol, the extract was cleaned-up quickly by C18 adsorbent, neutral alumina adsorbent and amino-functionalized nano-adsorbent. The separation was performed on a Shim-Pack XR-ODS II column (100 mm x 2.0 mm, 2.2 microm) using the mobile phases of 0.1% (v/v) formic acid in acetonitrile and 0.1% (v/v) formic acid solution in a gradient elution mode. The identification and quantification were achieved by using electrospray ionization in positive ion mode (ESI+) in multiple reaction monitoring (MRM) mode. The matrix-matched external standard calibration curves were used for quantitative determination. The results showed that the calibration curves were in good linearity for the eleven analytes with the correlation coefficients (r) more than 0.999. The limits of detection (LODs, S/N > 3) for the 11 anabolic hormones were from 0.03 microg/kg to 0.4 microg/kg and the limits of quantification (LOQs, S/N > 10) were from 0.1 microg/kg to 1.5 microg/kg. The average recoveries ranged from 80.9% to 98.1% with the relative standard deviations between 5.2% and 11.5%. The method is simple, rapid, sensitive, accurate and suitable for the quantitative determination and confirmation of the 11 anabolic hormones in fish.

  9. Determination of Bile Acids in Piglet Bile by Solid Phase Extraction and Liquid Chromatography-Electrospray Tandem Mass Spectrometry.

    PubMed

    Mi, Si; Lim, David W; Turner, Justine M; Wales, Paul W; Curtis, Jonathan M

    2016-03-01

    An LC/MS/MS-based method was developed for the determination of individual bile acids (BA) and their conjugates in porcine bile samples. The C18-based solid-phase extraction (SPE) procedure was optimized so that all 19 target BA and their glycine and taurine conjugates were collected with high recoveries for standards (89.1-100.2%). Following this, all 19 compounds were separated and quantified in a single 12 min chromatographic run. The method was validated in terms of linearity, sensitivity, accuracy, precision, and recovery. An LOD in the low ppb range with measured precisions in the range of 0.5-9.3% was achieved. The recoveries for all of the 19 analytes in bile samples were all >80%. The validated method was successfully applied to the profiling of BA and their conjugates in the bile from piglets treated with exogenous glucagon-like peptide-2 (GLP-2) in a preclinical model of neonatal parenteral nutrition-associated liver disease (PNALD). The method developed is rapid and could be easily implemented for routine analysis of BA and their conjugates in other biofluids or tissues.

  10. On-line MSPD-SPE-HPLC/FLD analysis of polycyclic aromatic hydrocarbons in bovine tissues.

    PubMed

    Gutiérrez-Valencia, Tania M; García de Llasera, Martha P

    2017-05-15

    A fast method was optimized and validated for simultaneous trace determination of four polycyclic aromatic hydrocarbons: benzo[a]anthracene, benzo[b]fluoranthene, benzo[k]fluoranthene and benzo[a]pyrene in bovine tissues. The determination was performed by matrix solid-phase dispersion (MSPD) coupled on-line to solid phase extraction (SPE) and high performance liquid chromatography (HPLC) with fluorescence detection (FLD). The sample was dispersed on C 18 silica sorbent and then the on-line MSPD-SPE-HPLC/FLD method was applied. Several parameters were optimized: cleaning and elution sequences applied to the MSPD cartridge, the flow rate and dilution of extract used for SPE loading. The on-line method was validated over a concentration range of 0.1-0.6ngg -1 obtaining good linearity (r⩾0.998) and precision (RSD)⩽10%. Recovery ranged from 96 to 99% and the limits of detection were 0.012ngg -1 . This methodology was applied to liver samples from unhealthy animals. The results demonstrate that MSDP-SPE-HPLC/FLD method provides reliable, sensitive, accurate and fast data to the food control. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. DFT calculation and experimental validation on the interactions of bis(trifluoromethylsulfonyl)imide and hexafluorophosphate with cesium

    NASA Astrophysics Data System (ADS)

    Sun, Taoxiang; Duan, Wuhua; Wang, Yaxing; Hu, Shaowen; Wang, Shuao; Chen, Jing; Shen, Xinghai

    2017-11-01

    Bis(trifluoromethylsulfonyl)imide (NTf2-) and hexafluorophosphate (PF6-) are the most frequently used anions for hydrophobic ionic liquids (ILs) which have been considered as promising solvents in the extraction of cesium ions. The interactions of NTf2- and PF6- with Cs+ were explored in this work. The results of DFT calculation indicated that both Cs+ and Cs(18C6)+ prefer to interact with two NTf2- or PF6- anions in gas phase, where 18C6 is 18-crown-6. The complex of Cs(NTf2)2- was observed in electrospray ionization mass spectrometry (ESI-MS), and the complexes of [Cs(18C6)NTf2]2 and [Cs(18C6)PF6]2 were crystallized in which Cs(18C6)+ interacted with two anions. The interactions of NTf2- with cesium resulted in a synergistic effect between dicyclohexano-18-crown-6 (DCH18C6) and NTf2- in the extraction of Cs+ using n-octanol as diluent. However, DFT calculation revealed that the complex Cs(DCH18C6)+ interacted with one NTf2- anion was more thermodynamically stable than that with two anions in organic phase, different from that in gas phase.

  12. Determination of selected UV filters in indoor dust by matrix solid-phase dispersion and gas chromatography-tandem mass spectrometry.

    PubMed

    Negreira, N; Rodríguez, I; Rubí, E; Cela, R

    2009-07-31

    A simple, inexpensive sample preparation procedure, based on the matrix solid-phase dispersion (MSPD) technique, for the determination of six UV filters: 2-ethylhexyl salicylate (EHS), 3,3,5-trimethylcyclohexyl salicylate (Homosalate, HMS), 3-(4-methylbenzylidene) camphor (4-MBC), isoamyl-p-methoxycinnamate (IAMC), 2-ethylhexyl-p-methoxycinnamate (EHMC) and octocrylene (OCR), in dust from indoor environments is presented and the influence of several operational parameters on the extraction performance discussed. Under the final working conditions, sieved samples (0.5 g) were mixed with the same amount of anhydrous sodium sulphate and dispersed with 2 g of octadecyl bonded silica (C18) in a mortar with a pestle. This blend was transferred to a polypropylene solid-phase extraction cartridge containing 2 g of activated silica, as the clean-up co-sorbent. The cartridge was first rinsed with 5 mL of n-hexane and the analytes were then recovered with 4 mL of acetonitrile. This extract was adjusted to 1 mL, filtered and the compounds were determined by gas chromatography combined with tandem mass spectrometry (GC-MS/MS). Recoveries for samples spiked at two different concentrations ranged between 77% and 99%, and the limits of quantification (LOQs) of the method between 10 and 40 ng g(-1). Analysis of settled dust from different indoor areas, including private flats, public buildings and vehicle cabins, showed that EHMC and OCR were ubiquitous in this matrix, with maximum concentrations of 15 and 41 microg g(-1), respectively. Both UV filters were also quantified in dust reference material SRM 2585 for first time. EHS, 4-MBC and IAMC were detected in some of the analyzed samples, although at lower concentrations than EHMC and OCR.

  13. Tandem solid-phase extraction followed by HPLC-ESI/QTOF/MS/MS for rapid screening and structural identification of trace diterpenoids in flowers of Rhododendron molle.

    PubMed

    Zou, Hong-Yan; Luo, Jun; Xu, De-Ran; Kong, Ling-Yi

    2014-01-01

    'Naoyanghua', composed of the flowers of Rhododendron molle G. Don, is a traditional Chinese medicine that is widely known for its toxicity. Grayanane-type diterpenoids are the main active ingredients in R. molle, as well as possibly their toxicity: they are, however, difficult to isolate and analyse using common chromatographic methods, due to their small amounts and absence of conjugated groups, such as phenyl and α, β-unsaturated ketone. To establish a highly sensitive, selective and reliable method for the qualitative evaluation of trace diterpenoids in the flowers of R. molle by using tandem solid-phase extraction followed by high-performance liquid chromatography with electrospray ionisation quadrupole-time-of-flight mass spectrometry (HPLC-ESI/QTOF/MS/MS). Tandem solid phase extraction (SPE) was undertaken using a polyamide cartridge and a C18E cartridge in succession to enrich the trace diterpenoids. HPLC-ESI/QTOF/MS/MS was used to determine the fragmentation patterns of diterpenoids and to tentatively characterise their fragmentation pathways. HPLC-ESI/QTOF/MS/MS detected a total of 14 diterpenoids, eight of which were identified by comparison with literature sources and six based on fragmentation analysis. Among the latter six, rhodojaponin VI-3-glucoside was tentatively identified as a new diterpenoid glycoside and rhodojaponin VII, rhodojaponin IV and rhodojaponin I were reported from R. molle for the first time. By qualitative research of diterpenoids in this plant by HPLC-ESI/QTOF/MS/MS, a reliable methodology for the analysis of these active constituents of R. molle was established for the first time. Copyright © 2014 John Wiley & Sons, Ltd.

  14. Solvent Extraction Separation of Trivalent Americium from Curium and the Lanthanides

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jensen, Mark P.; Chiarizia, Renato; Ulicki, Joseph S.

    2015-02-27

    The sterically constrained, macrocyclic, aqueous soluble ligand N,N'-bis[(6-carboxy-2-pyridyl)methyl]-1,10-diaza-18-crown-6 (H2BP18C6) was investigated for separating americium from curium and all the lanthanides by solvent extraction. Pairing H2BP18C6, which favors complexation of larger f-element cations, with acidic organophosphorus extractants that favor extraction of smaller f-element cations, such as bis-(2-ethylhexyl)phosphoric acid (HDEHP) or (2-ethylhexyl)phosphonic acid mono(2-ethylhexyl) ester (HEH[EHP]), created solvent extraction systems with good Cm/Am selectivity, excellent trans-lanthanide selectivity (Kex,Lu/Kex,La = 108), but poor selectivity for Am against the lightest lanthanides. However, using an organic phase containing both a neutral extractant, N,N,N’,N’-tetra(2-ethylhexyl)diglycolamide (TEHDGA), and HEH[EHP] enabled rejection of the lightest lanthanides during loading ofmore » the organic phase from aqueous nitric acid, eliminating their interference in the americium stripping stages. In addition, although it is a macrocyclic ligand, H2BP18C6 does not significantly impede the mass transfer kinetics of the HDEHP solvent extraction system« less

  15. Production and partial purification of tannase from Aspergillus ficuum Gim 3.6.

    PubMed

    Ma, Wan-liang; Zhao, Fen-fen; Ye, Qin; Hu, Zhen-xing; Yan, Dong; Hou, Jie; Yang, Yang

    2015-01-01

    A novel fungal strain, Aspergillus ficuum Gim 3.6, was evaluated for its tannase-producing capability in a wheat bran-based solid-state fermentation. Thin-layer chromatography (TLC) analysis revealed that the strain was able to degrade tannic acid to gallic acid and pyrogallol during the fermentation process. Quantitation of enzyme activity demonstrated that this strain was capable of producing a relatively high yield of extracellular tannase. Single-factor optimization of process parameters resulted in high yield of tannase after 60 hr of incubation at a pH of 5.0 at 30°C, 1 mL of inoculum size, and 1:1 solid-liquid ratio in the presence of 2.0% (w/v) tannic acid as inducer. The potential of aqueous two-phase extraction (ATPE) for the purification of tannase was investigated. Influence of various parameters such as phase-forming salt, molecular weight of polyethylene glycol (PEG), pH, and stability ratio on tannase partition and purification was studied. In all the systems, the target enzyme was observed to preferentially partition to the PEG-rich top phase, and the best result of purification (2.74-fold) with an enzyme activity recovery of 77.17% was obtained in the system containing 17% (w/w) sodium citrate and 18.18% (w/w) PEG1000, at pH 7.0.

  16. Development of a fully automated on-line solid phase extraction and high-performance liquid chromatography with diode array detection method for the pharmacokinetic evaluation of bavachinin: a study on absolute bioavailability and dose proportionality.

    PubMed

    Liu, Lei; Liu, Kang-Ning; Wen, Ya-Bin; Zhang, Han-Wen; Lu, Ya-Xin; Yin, Zheng

    2012-04-15

    A fully automated on-line solid-phase extraction (SPE) and high-performance liquid chromatography (HPLC) with diode array detection (DAD) method was developed for determination of bavachinin in mouse plasma. Analytical process was performed on two reversed-phase columns (SPE cartridge and analytical column) connected via a Valco 6-port switching valve. Plasma samples (10 μL) were injected directly onto a C18 SPE cartridge (MF Ph-1 C18, 10 mm × 4 mm, 5 μm) and the biological matrix was washed out for 2 min with the loading solvent (5 mM NaH(2)PO(4) buffer, pH 3.5) at a flow rate of 1 mL/min. By rotation of the switching valve, bavachinin was eluted from the SPE cartridge in the back-flush mode and transferred to the analytical column (Venusil MP C18, 4.6 mm × 150 mm, 5 μm) by the chromatographic mobile phase consisted of acetonitrile-5mM NaH(2)PO(4) buffer 65/35 (v/v, pH 3.5) at a flow rate of 1 mL/min. The complete cycle of the on-line SPE purification and chromatographic separation of the analyte was 13 min with UV detection performed at 236 nm. Calibration curve with good linearity (r=0.9997) was obtained in the range of 20-4000 ng/mL in mouse plasma. The intra-day and inter-day precisions (RSD) of bavachinin were in the range of 0.20-2.32% and the accuracies were between 98.47% and 102.95%. The lower limit of quantification (LLOQ) of the assay was 20 ng/mL. In conclusion, the established automated on-line SPE-HPLC-DAD method demonstrated good performance in terms of linearity, specificity, detection and quantification limits, precision and accuracy, and was successfully utilized to quantify bavachinin in mouse plasma to support the pharmacokinetic (PK) studies. The PK properties of bavachinin were characterized as rapid oral absorption, high clearance, and poor absolute bioavailability. Copyright © 2012. Published by Elsevier B.V.

  17. [Simultaneous determination of ten benzotriazole ultraviolet stabilizers in food contact plastic materials by solid phase extraction and ultra performance liquid chromatography with tandem mass spectrometry].

    PubMed

    Gou, Xinlei; Zhao, Xinying; Chi, Haitao; Gao, Xia; Zhou, Mingqiang; Liu, Weili

    2015-06-01

    A sensitive method was developed for the simultaneous determination of ten benzotriazole ultraviolet stabilizers in food contact plastic materials by ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The sample was extracted by methanol-dichloromethane, and purified by a C18 solid-phase extraction (SPE) column. The separation was performed by using water containing 0. 1% (v/v) formic acid and methanol as the mobile phases with gradient elution at a flow rate of 0. 3 mL/min. The electrospray ionization (ESI) source in positive ion mode was used for the analysis of the ten benzotriazole ultraviolet stabilizers in multiple reaction monitoring (MRM) mode. The results showed that the standard curves were obtained with good correlation coefficients (r2 > 0.996) in their linear concentration ranges. The limits of detection (LODs, S/N = 3) for the ten benzotriazole ultraviolet stabilizers were in the range of 0.6-1.6 µg/kg. The mean recoveries for the ten benzotriazole ultraviolet stabilizers at three spiked levels (low, medium and high) were 75.2%-85.3% with relative standard deviations of 1.0%-5.7%. Ten kinds of food contact plastic materials were tested, and 2,2'-methylenebis (6-(benzotriazol-2-yl)-4-tert-octylphenol) (UV-360) was found in a sample of polyethylene (PE) material. The method is accurate, simple, rapid and feasible for the simultaneous determination of benzotriazole ultraviolet stabilizers in food plastic materials.

  18. Identification of alkyl dimethylbenzylammonium surfactants in water samples by solid-phase extraction followed by ion trap LC/MS and LC/MS/MS

    USGS Publications Warehouse

    Ferrer, I.; Furlong, E.T.

    2001-01-01

    A novel methodology was developed for the determination of alkyl (C12, C14, and C16) dimethylbenzylammonium chloride (benzalkonium chloride or BAC, Chemical Abstract Service number: 8001-54-5) in water samples. This method is based on solid-phase extraction (SPE) using polymeric cartridges, followed by high-performance liquid chromatography/ion trap mass spectrometry (LC/MS) and tandem mass spectrometry(MS/MS) detection, equipped with an electrospray interface in positive ion mode. Chromatographic separation was achieved for three BAC homologues by using a C18 column and a gradient of acetonitrile/10 millimolar aqueous ammonium formate. Total method recoveries were higher than 71% in different water matrices. The main ions observed by LC/MS were at mass-to-charge ratios (m/z) of 304, 332, and 360, which correspond to the molecular ions of the C12, C14, and C16 alkyl BAC, respectively. The unequivocal structural identification of these compounds in water samples was performed by LC/MS/MS after isolation and subsequent fragmentation of each molecular ion. The main fragmentation observed for the three different homologues corresponded to the loss of the toluyl group in the chemical structure, which leads to the fragment ions at m/z 212, 240, and 268 and a tropylium ion, characteristic of all homologues, at m/z 91. Detection limits for the methodology developed in this work were in the low nanogram-per-liter range. Concentration levels of BAC - ranging from 1.2 to 36.6 micrograms per liter - were found in surface-water samples collected downstream from different wastewater-treatment discharges, thus indicating its input and persistence through the wastewater-treatment process.

  19. Sol-gel niobia sorbent with a positively charged octadecyl ligand providing enhanced enrichment of nucleotides and organophosphorus pesticides in capillary microextraction for online HPLC analysis.

    PubMed

    Kesani, Sheshanka; Malik, Abdul

    2018-04-01

    A niobia-based sol-gel organic-inorganic hybrid sorbent carrying a positively charged C 18 ligand (Nb 2 O 5 -C 18 (+ve)) was synthesized to achieve enhanced enrichment capability in capillary microextraction of organophosphorus compounds (which include organophosphorus pesticides and nucleotides) before their online analysis by high-performance liquid chromatography. The sorbent was designed to simultaneously provide three different types of molecular level interactions: electrostatic, Lewis acid-base, and van der Waals interactions. To understand relative contributions of various molecular level analyte-sorbent interactions in the extraction process, two other sol-gel niobia sorbents were also created: (a) a purely inorganic sol-gel niobia sorbent (Nb 2 O 5 ) and (b) an organic-inorganic hybrid sol-gel niobia sorbent carrying an electrically neutral-bonded octadecyl ligand (Nb 2 O 5 -C 18 ). The extraction efficiency of the created sol-gel niobia sorbent (Nb 2 O 5 -C 18 (+ve)) was compared with that of analogously designed and synthesized titania-based sol-gel sorbent (TiO 2 -C 18 (+ve)), taking into consideration that titania-based sorbents present state-of-the-art extraction media for organophosphorus compounds. In capillary microextraction with high-performance liquid chromatography analysis, Nb 2 O 5 -C 18 (+ve) had shown 40-50% higher specific extraction values (a measure of extraction efficiency) over that of TiO 2 -C 18 (+ve). Compared to TiO 2 -C 18 (+ve), Nb 2 O 5 -C 18 (+ve) also provided superior analyte desorption efficiency (96 vs. 90%) during the online release of the extracted organophosphorus pesticides from the sorbent coating in the capillary microextraction capillary to the chromatographic column using reversed-phase high-performance liquid chromatography mobile phase. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Simultaneous extraction and determination of phthalate esters in aqueous solution by yolk-shell magnetic mesoporous carbon-molecularly imprinted composites based on solid-phase extraction coupled with gas chromatography-mass spectrometry.

    PubMed

    Yang, Rui; Liu, Yuxin; Yan, Xiangyang; Liu, Shaomin

    2016-12-01

    A rapid, sensitive and accurate method for the simultaneous extraction and determination of five types of trace phthalate esters (PAEs) in environmental water and beverage samples using magnetic molecularly imprinted solid-phase extraction (MMIP-SPE) coupled with gas chromatography-mass spectrometry (GC-MS) was developed. A novel type of molecularly imprinted polymers on the surface of yolk-shell magnetic mesoporous carbon (Fe 3 O 4 @void@C-MIPs) was used as an efficient adsorbent for selective adsorption of phthalate esters based on magnetic solid-phase extraction (MSPE). The real samples were first preconcentrated by Fe 3 O 4 @void@C-MIPs, subsequently extracted by eluent and finally determined by GC-MS after magnetic separation. Several variables affecting the extraction efficiency of the analytes, including the type and volume of the elution solvent, amount of adsorbent, extraction time, desorption time and pH of the sample solution, were investigated and optimized. Validation experiments indicated that the developed method presented good linearity (R 2 >0.9961), satisfactory precision (RSD<6.7%), and high recovery (86.1-103.1%). The limits of detection ranged from 1.6ng/L to 5.2ng/L and the enrichment factor was in the range of 822-1423. The results indicated that the novel method had the advantages of convenience, good sensitivity, and high efficiency, and it could also be successfully applied to the analysis of PAEs in real samples. Copyright © 2016. Published by Elsevier B.V.

  1. Optimization of the SPME parameters and its online coupling with HPLC for the analysis of tricyclic antidepressants in plasma samples.

    PubMed

    Alves, Claudete; Fernandes, Christian; Dos Santos Neto, Alvaro José; Rodrigues, José Carlos; Costa Queiroz, Maria Eugênia; Lanças, Fernando Mauro

    2006-07-01

    Solid-phase microextraction (SPME)-liquid chromatography (LC) is used to analyze tricyclic antidepressant drugs desipramine, imipramine, nortriptyline, amitriptyline, and clomipramine (internal standard) in plasma samples. Extraction conditions are optimized using a 2(3) factorial design plus a central point to evaluate the influence of the time, temperature, and matrix pH. A Polydimethylsiloxane-divinylbenzene (60-mum film thickness) fiber is selected after the assessment of different types of coating. The chromatographic separation is realized using a C(18) column (150 x 4.6 mm, 5-microm particles), ammonium acetate buffer (0.05 mol/L, pH 5.50)-acetonitrile (55:45 v/v) with 0.1% of triethylamine as mobile phase and UV-vis detection at 214 nm. Among the factorial design conditions evaluated, the best results are obtained at a pH 11.0, temperature of 30 degrees C, and extraction time of 45 min. The proposed method, using a lab-made SPME-LC interface, allowed the determination of tricyclic antidepressants in in plasma at therapeutic concentration levels.

  2. Barium alginate caged Fe3O4@C18 magnetic nanoparticles for the pre-concentration of polycyclic aromatic hydrocarbons and phthalate esters from environmental water samples.

    PubMed

    Zhang, Shengxiao; Niu, Hongyun; Cai, Yaqi; Shi, Yali

    2010-04-30

    The hydrophobic octadecyl (C(18)) functionalized Fe(3)O(4) magnetic nanoparticles (Fe(3)O(4)@C(18)) were caged into hydrophilic barium alginate (Ba(2+)-ALG) polymers to obtain a novel type of solid-phase extraction (SPE) sorbents, and the sorbents were applied to the pre-concentration of polycyclic aromatic hydrocarbons (PAHs) and phthalate esters (PAEs) pollutants from environmental water samples. The hydrophilicity of the Ba(2+)-ALG cage enhances the dispersibility of sorbents in water samples, and the superparamagnetism of the Fe(3)O(4) core facilitates magnetic separation. With the magnetic SPE technique based on the Fe(3)O(4)@C(18)@Ba(2+)-ALG sorbents, it requires only 30 min to extract trace levels of analytes from 500 mL water samples. After the eluate is condensed to 0.5 mL, concentration factors for both phenanthrene and di-n-propyl-phthalate are over 500, while for other analytes are about 1000. The recoveries of target compounds are independent of salinity and solution pH under testing conditions. Under optimized conditions, the detection limits for phenanthrene, pyrene, benzo[a]anthracene, and benzo[a]pyrene are 5, 5, 3, and 2 ng L(-1), and for di-n-propyl-phthalate, di-n-butyl-phthalate, di-cyclohexyl-phthalate, and di-n-octyl-phthalate are 36, 59, 19, and 36 ng L(-1), respectively. The spiked recoveries of several real water samples for PAHs and PAEs are in the range of 72-108% with relative standard deviations varying from 1% to 9%, showing good accuracy of the method. The advantages of the new SPE method include high extraction efficiency, short analysis time and convenient extraction procedure. To the best of our knowledge, it is unprecedented that hydrophilic Ba(2+)-ALG polymer caged Fe(3)O(4)@C(18) magnetic nanomaterial is used to extract organic pollutants from large volumes of water samples. Copyright 2010 Elsevier B.V. All rights reserved.

  3. Solid-phase microextraction Ni-Ti fibers coated with functionalised silica particles immobilized in a sol-gel matrix.

    PubMed

    Azenha, Manuel; Ornelas, Mariana; Fernando Silva, A

    2009-03-20

    One of the possible approaches for the development of novel solid-phase microextraction (SPME) fibers is the physical deposition of porous materials onto a support using high-temperature epoxy glue. However, a major drawback arises from decomposition of epoxy glue at temperatures below 300 degrees C and instability in some organic solvents. This limitation motivated us to explore the possibility of replacing the epoxy glue with a sol-gel film, thermally more stable and resistant to organic solvents. We found that functionalised silica particles could be successfully attached to a robust Ni-Ti wire by using a UV-curable sol-gel film. The particles were found to be more important than the sol-gel layer during the microextraction process, as shown by competitive extraction trials and by the different extraction profiles observed with differently functionalised particles. If a quality control microscopic-check aiming at the rejection of fibers exhibiting unacceptably low particle load was conducted, acceptable (6-14%) reproducibility of preparation of C(18)-silica fibers was observed, and a strong indication of the durability of the fibers was also obtained. A cyclohexyldiol-silica fiber was used, as a simple example of applicability, for the successful determination of benzaldehyde, acetophenone and dimethylphenol at trace level in spiked tap water. Recoveries: 95-109%; limits of detection: 2-7 microg/L; no competition effects within the studied range (

  4. Procedure for the determination of retinol and alpha-tocopherol in poultry tissues using capillary gas chromatography with solvent venting injection.

    PubMed

    Maraschiello, C; García Regueiro, J A

    1998-08-28

    A procedure designed for the determination of retinol (vitamin A) and alpha-tocopherol (vitamin E) in poultry tissues has been developed. The procedure involves lipid extraction, saponification, solid-phase clean-up and capillary gas chromatography (cGC). Retinol and alpha-tocopherol were determined separately by cGC-flame ionisation detection using a fused-silica open tubular capillary column, 30 m x 0.25 mm I.D. coated with 5% phenylmethylsilicone and with a film thickness of 0.25 micron. Solvent extraction followed by saponification were sufficient to provide a purified extract which was directly analyzed for retinol by cGC in the solvent venting mode. However, in order to accurately determine alpha-tocopherol by cGC, further purification of the extract by solid-phase extraction was necessary. A silica SPE column was used to remove interfering cholesterol from the extract. alpha-Tocopherol was analyzed in its derivatized form. Absolute and relative recoveries for both vitamins from spiked samples were evaluated. Absolute and relative recoveries ranging from 80 to 95% were obtained for both compounds. 5 alpha-Cholestane and alpha-tocopheryl acetate were used as internal standards. Poultry muscle meat and liver tissue were analyzed for their retinol and alpha-tocopherol content and the peaks detected by cGC were confirmed by cGC-mass spectrometry.

  5. Quick, easy, cheap, effective, rugged, and safe sample preparation approach for pesticide residue analysis using traditional detectors in chromatography: A review.

    PubMed

    Rahman, Md Musfiqur; Abd El-Aty, A M; Kim, Sung-Woo; Shin, Sung Chul; Shin, Ho-Chul; Shim, Jae-Han

    2017-01-01

    In pesticide residue analysis, relatively low-sensitivity traditional detectors, such as UV, diode array, electron-capture, flame photometric, and nitrogen-phosphorus detectors, have been used following classical sample preparation (liquid-liquid extraction and open glass column cleanup); however, the extraction method is laborious, time-consuming, and requires large volumes of toxic organic solvents. A quick, easy, cheap, effective, rugged, and safe method was introduced in 2003 and coupled with selective and sensitive mass detectors to overcome the aforementioned drawbacks. Compared to traditional detectors, mass spectrometers are still far more expensive and not available in most modestly equipped laboratories, owing to maintenance and cost-related issues. Even available, traditional detectors are still being used for analysis of residues in agricultural commodities. It is widely known that the quick, easy, cheap, effective, rugged, and safe method is incompatible with conventional detectors owing to matrix complexity and low sensitivity. Therefore, modifications using column/cartridge-based solid-phase extraction instead of dispersive solid-phase extraction for cleanup have been applied in most cases to compensate and enable the adaptation of the extraction method to conventional detectors. In gas chromatography, the matrix enhancement effect of some analytes has been observed, which lowers the limit of detection and, therefore, enables gas chromatography to be compatible with the quick, easy, cheap, effective, rugged, and safe extraction method. For liquid chromatography with a UV detector, a combination of column/cartridge-based solid-phase extraction and dispersive solid-phase extraction was found to reduce the matrix interference and increase the sensitivity. A suitable double-layer column/cartridge-based solid-phase extraction might be the perfect solution, instead of a time-consuming combination of column/cartridge-based solid-phase extraction and dispersive solid-phase extraction. Therefore, replacing dispersive solid-phase extraction with column/cartridge-based solid-phase extraction in the cleanup step can make the quick, easy, cheap, effective, rugged, and safe extraction method compatible with traditional detectors for more sensitive, effective, and green analysis. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Analysis of preservatives with different polarities in beverage samples by dual-phase dual stir bar sorptive extraction combined with high-performance liquid chromatography.

    PubMed

    Xu, Jin; Chen, Beibei; He, Man; Hu, Bin

    2013-02-22

    A new concept of "dual-phase dual stir bar sorptive extraction (SBSE)" was proposed to simultaneously extract six preservatives with different polarities (logKo/w values of 1.27-3.41), namely, benzoic acid (BA), sorbic acid (SA), methyl p-hydroxybenzoate (MP), ethyl p-hydroxybenzoate (EP), propyl p-hydroxybenzoate (PP), and butyl p-hydroxybenzoate (BP). The dual-phase dual SBSE apparatus was consisted of two differently coated stir bars, a 3-aminopropyltriethoxysilane (APTES)-hydroxy-terminated silicone oil (OH-TSO)-coated stir bar that was prepared by sol-gel technique and a C(18) silica (C(18))-polydimethylsiloxane (PDMS)-coated stir bar that was prepared by adhesion. In dual-phase dual SBSE, the two stir bars with different coatings were placed in the same sample solution for the simultaneous extraction of the target analytes with different polarities, and then the bars were desorbed in the same desorption solvent. The extraction performance of the dual-phase dual SBSE for the six preservatives was evaluated by comparing with the conventional SBSE (individual stir bar) with different coatings, including commercial PDMS, homemade PDMS, C(18)-APTES-OH-TSO, APTES-OH-TSO, and C(18)-PDMS. The experimental results showed that the dual-phase dual SBSE had the highest extraction efficiency for the six target preservatives. Based on this fact, a novel method by combining the dual-phase dual SBSE which was consisted of the APTES-OH-TSO-coated and C(18)-PDMS-coated stir bars with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was developed for the simultaneous analysis of six target beverage preservatives in beverages. Under optimal conditions, the limits of detection (LODs) for six target preservatives ranged from 0.6 to 2.7 μgL(-1) with the relative standard deviations (RSDs) of 4.6-9.2% (C(BA,SA)=5 μgL(-1),C(MP)=20 μgL(-1),C(EP,PP,BP)=10 μgL(-1), n=7). The enrichment factors (EFs) were approximately 16-42-fold (theoretical EF was 50-fold). The proposed method was validated by the analysis of six target preservatives in three kinds of beverage samples, and the recoveries for the spiked samples were in the range of 76.6-118.6% for cola, 74.6-17.5% for orange juice, and 83.0-119.1% for herbal tea, respectively. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Rate-dependent, Li-ion insertion/deinsertion behavior of LiFePO4 cathodes in commercial 18650 LiFePO4 cells.

    PubMed

    Liu, Qi; He, Hao; Li, Zhe-Fei; Liu, Yadong; Ren, Yang; Lu, Wenquan; Lu, Jun; Stach, Eric A; Xie, Jian

    2014-03-12

    We have performed operando synchrotron high-energy X-ray diffraction (XRD) to obtain nonintrusive, real-time monitoring of the dynamic chemical and structural changes in commercial 18650 LiFePO4/C cells under realistic cycling conditions. The results indicate a nonequilibrium lithium insertion and extraction in the LiFePO4 cathode, with neither the LiFePO4 phase nor the FePO4 phase maintaining a static composition during lithium insertion/extraction. On the basis of our observations, we propose that the LiFePO4 cathode simultaneously experiences both a two-phase reaction mechanism and a dual-phase solid-solution reaction mechanism over the entire range of the flat voltage plateau, with this dual-phase solid-solution behavior being strongly dependent on charge/discharge rates. The proposed dual-phase solid-solution mechanism may explain the remarkable rate capability of LiFePO4 in commercial cells.

  8. A review on solid phase extraction of actinides and lanthanides with amide based extractants.

    PubMed

    Ansari, Seraj A; Mohapatra, Prasanta K

    2017-05-26

    Solid phase extraction is gaining attention from separation scientists due to its high chromatographic utility. Though both grafted and impregnated forms of solid phase extraction resins are popular, the later is easy to make by impregnating a given organic extractant on to an inert solid support. Solid phase extraction on an impregnated support, also known as extraction chromatography, combines the advantages of liquid-liquid extraction and the ion exchange chromatography methods. On the flip side, the impregnated extraction chromatographic resins are less stable against leaching out of the organic extractant from the pores of the support material. Grafted resins, on the other hand, have a higher stability, which allows their prolong use. The goal of this article is a brief literature review on reported actinide and lanthanide separation methods based on solid phase extractants of both the types, i.e., (i) ligand impregnation on the solid support or (ii) ligand functionalized polymers (chemically bonded resins). Though the literature survey reveals an enormous volume of studies on the extraction chromatographic separation of actinides and lanthanides using several extractants, the focus of the present article is limited to the work carried out with amide based ligands, viz. monoamides, diamides and diglycolamides. The emphasis will be on reported applied experimental results rather than on data pertaining fundamental metal complexation. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Homogeneous synthesis of cellulose acrylate-g-poly (n-alkyl acrylate) solid-solid phase change materials via free radical polymerization.

    PubMed

    Qian, Yong-Qiang; Han, Na; Bo, Yi-Wen; Tan, Lin-Li; Zhang, Long-Fei; Zhang, Xing-Xiang

    2018-08-01

    A novel solid-solid phase change materials, namely, cellulose acrylate-g-poly (n-alkyl acrylate) (CA-g-PAn) (n = 14, 16 and 18) were successfully synthesized by free radical polymerization in N, N-dimethylacetamide (DMAc). The successful grafting was confirmed by fourier transform infrared spectra (FT-IR) and nuclear magnetic resonance (NMR). The properties of the CA-g-PAn copolymers were investigated by differential scanning calorimetry (DSC), thermogravimetric analysis (TGA). The phase change temperatures and the melting enthalpies of CA-g-PAn copolymers are in the range of 10.1-53.2 °C and 15-95 J/g, respectively. It can be adjusted by the contents of poly (n-alkyl acrylate) and the length of alkyl side-chain. The thermal resistant temperatures of CA-g-PA14, 16 and 18 copolymers are 308 °C, 292 °C and 273 °C, respectively. It show that all of grafting materials exhibit good thermal stability and shape stability. Therefore, it is expected to be applied in the cellulose-based thermos-regulating field. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. Densitometric thin-layer chromatographic determination of aescin in a herbal medicinal product containing Aesculus and Vitis dry extracts.

    PubMed

    Apers, Sandra; Naessens, Tania; Pieters, Luc; Vlietinck, Arnold

    2006-04-21

    A thin-layer chromatographic (TLC) method is developed to analyze the total saponin content, also referred to as the aescin content, in a herbal medicinal product (HMP) containing two dry extracts in capsules. The capsules contain 250 mg of Aesculus hippocastanum dry extract, 120 mg of Vitis vinifera dry extract and 50mg of excipients. After a purification step using C(18) solid phase extraction (SPE) cartridges, the samples are analyzed on a silica-gel HPTLC plate with the upper layer of a mixture of acetic acid/water/butanol (10/40/50 v/v/v) as the mobile phase. Spots are visualized by spraying with anisaldehyde reagent and heating the plate for 5-10 min (100-105 degrees C) and measured at a wavelength of 535 nm. This method, applicable for the quality control and stability investigation of both the Aesculus dry extract and HMP capsules thereof containing Vitis dry extract in combination with the Aesculus dry extract, is validated according to the International Conference on Harmonization (ICH) guidelines. The proposed assay method is specific for aescin in the presence of Vitis dry extract and formulation excipients. Analysis of stressed samples in forced degradation tests proves the method to be applicable for stability evaluation. The standard aescin curve is linear (r > 0.99) over a concentration range of 0.16-0.80 microg/spot. Recovery from the HMP capsules is statistically equal to 100%. The precision of the method with respect to time and concentration is acceptable, with relative standard deviation (RSD) values of 1.28 and 1.49%, respectively.

  11. Improved micromethod for mezlocillin quantitation in serum and urine by high-pressure liquid chromatography.

    PubMed Central

    Fiore, D; Auger, F A; Drusano, G L; Dandu, V R; Lesko, L J

    1984-01-01

    A rapid, sensitive, and specific method of analysis for mezlocillin in serum and urine by high-pressure liquid chromatography is described. A solid-phase extraction column was used to remove interfering substances from samples before chromatography. Quantitation included the use of an internal standard, nafcillin. Mezlocillin was chromatographed with a phosphate buffer-acetonitrile (73:27) mobile phase and a C-18 reverse-phase column and detected at a wavelength of 220 nm. The assay had a sensitivity of 1.6 micrograms/ml and a linearity of up to 600 micrograms/ml and 16 mg/ml in serum and urine, respectively, with only 0.1 ml of sample. The interday and intraday coefficients of variation for replicate analyses of spiked serum and urine specimens were less than 6.5%. PMID:6517560

  12. Profiling intact steroid sulfates and unconjugated steroids in biological fluids by liquid chromatography-tandem mass spectrometry (LC-MS-MS).

    PubMed

    Galuska, Christina E; Hartmann, Michaela F; Sánchez-Guijo, Alberto; Bakhaus, Katharina; Geyer, Joachim; Schuler, Gerhard; Zimmer, Klaus-Peter; Wudy, Stefan A

    2013-07-07

    Within the combined DFG research project "Sulfated Steroids in Reproduction" an analytical method was needed for determining sulfated and unconjugated steroids with highest specificity out of different biological matrices such as aqueous solution, cell lysate and serum. With regard to this analytical challenge, LC-MS-MS presents the technique of choice because it permits (1) analysis of the intact steroid conjugate, (2) allows for simultaneous determination of multiple analytes (profiling, targeted metabolomics approach) and (3) is independent of phenomena such as cross-reactivity. Sample work up consisted of incubation of sample with internal standards (deuterium labeled steroids) followed by solid phase extraction. Only serum samples required a protein precipitation step prior to solid phase extraction. The extract was divided in two parts: six steroid sulfates (E1S, E2S, AS, 16-OH-DHEAS, PREGS, DHEAS) were analyzed by C18aQ-ESI-MS-MS in negative ion mode and eleven unconjugated steroids (E3, 16-OH-DHEA, E1, E2, (4)A, DHEA, T, 17-OH-PREG, Prog, An, PREG) were analyzed by C18-APCI-MS-MS in positive ion mode. For steroid sulfates, we found high sensitivities with LoQ values ranging from 0.08 to 1 ng mL(-1). Unconjugated steroids showed LoQ values between 0.5 and 10 ng mL(-1). Calibration plots showed excellent linearity. Mean intra- and inter-assay CVs were 2.4% for steroid sulfates and 6.4% for unconjugated steroids. Accuracy - determined in a two-level spike experiment - showed mean relative errors of 5.9% for steroid sulfates and 6.1% for unconjugated steroids. In summary, we describe a novel LC-MS-MS procedure capable of profiling six steroid sulfates and eleven unconjugated steroids from various biological matrices.

  13. Rapid extraction and determination of 25 bioactive constituents in Alpinia oxyphylla using microwave extraction with ultra high performance liquid chromatography with tandem mass spectrometry.

    PubMed

    Sun, Zhi; Kong, Xiangzhen; Zuo, Lihua; Kang, Jian; Hou, Lei; Zhang, Xiaojian

    2016-02-01

    A novel and rapid microwave extraction and ultra high performance liquid chromatography with tandem mass spectrometry method was developed and validated for the simultaneous determination of 25 bioactive constituents (including two new constituents) in Fructus Alpinia oxyphylla. The optimized conditions of the microwave extraction was a microwave power of 300 W, extraction temperature of 80°C, solvent-to-solid ratio of 30 mL/g and extraction time of 8 min. Separation was achieved on a Waters ACQUITY UPLC(®) HSS C18 column (2.1 mm× 50 mm, 1.8 μm) using gradient elution with a mobile phase consisting of acetonitrile and 1 mM ammonium acetate at a flow rate of 0.2 mL/min. This is the first report of the simultaneous determination of 25 bioactive constituents in Fructus Alpinia oxyphylla by ultra high performance liquid chromatography with tandem mass spectrometry. The method was validated with good linearity, acceptable precision and accuracy. The validated method was successfully applied to determine the contents of 25 bioactive constituents in Fructus Alpinia oxyphylla from different sources and the analysis results were classified by hierarchical cluster analysis, which indicated the effect of different cultivation regions on the contents of constituents. This study provides powerful and practical guidance in the quality control of Alpinia oxyphylla and lays the foundation for further research of Alpinia oxyphylla. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. A fully-automated one-pot synthesis of [18F]fluoromethylcholine with reduced dimethylaminoethanol contamination via [18F]fluoromethyl tosylate.

    PubMed

    Rodnick, Melissa E; Brooks, Allen F; Hockley, Brian G; Henderson, Bradford D; Scott, Peter J H

    2013-08-01

    A novel one-pot method for preparing [(18)F]fluoromethylcholine ([(18)F]FCH) via in situ generation of [(18)F]fluoromethyl tosylate ([(18)F]FCH2OTs), and subsequent [(18)F]fluoromethylation of dimethylaminoethanol (DMAE), has been developed. [(18)F]FCH was prepared using a GE TRACERlab FXFN, although the method should be readily adaptable to any other fluorine-(18) synthesis module. Initially ditosylmethane was fluorinated to generate [(18)F]FCH2OTs. DMAE was then added and the reaction was heated at 120 °C for 10 min to generate [(18)F]FCH. After this time, reaction solvent was evaporated, and the crude reaction mixture was purified by solid-phase extraction using C(18)-Plus and CM-Light Sep-Pak cartridges to provide [(18)F]FCH formulated in USP saline. The formulated product was passed through a 0.22 µm filter into a sterile dose vial, and submitted for quality control testing. Total synthesis time was 1.25 h from end-of-bombardment. Typical non-decay-corrected yields of [(18)F]FCH prepared using this method were 91 mCi (7% non-decay corrected based upon ~1.3 Ci [(18)F]fluoride), and doses passed all other quality control (QC) tests. A one-pot liquid-phase synthesis of [(18)F]FCH has been developed. Doses contain extremely low levels of residual DMAE (31.6 µg/10 mL dose or ~3 ppm) and passed all other requisite QC testing, confirming their suitability for use in clinical imaging studies. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. A Fully-automated One-pot Synthesis of [18F]Fluoromethylcholine with Reduced Dimethylaminoethanol Contamination via [18F]Fluoromethyl Tosylate

    PubMed Central

    Rodnick, Melissa E.; Brooks, Allen F.; Hockley, Brian G.; Henderson, Bradford D.; Scott, Peter J. H.

    2013-01-01

    Introduction A novel one-pot method for preparing [18F]fluoromethylcholine ([18F]FCH) via in situ generation of [18F]fluoromethyl tosylate ([18F]FCH2OTs), and subsequent [18F]fluoromethylation of dimethylaminoethanol (DMAE), has been developed. Methods [18F]FCH was prepared using a GE TRACERlab FXFN, although the method should be readily adaptable to any other fluorine-18 synthesis module. Initially ditosylmethane was fluorinated to generate [18F]FCH2OTs. DMAE was then added and the reaction was heated at 120°C for 10 min to generate [18F]FCH. After this time, reaction solvent was evaporated, and the crude reaction mixture was purified by solid-phase extraction using C18-Plus and CM-Light Sep-Pak cartridges to provide [18F]FCH formulated in USP saline. The formulated product was passed through a 0.22 μm filter into a sterile dose vial, and submitted for quality control testing. Total synthesis time was 1.25 hours from end-of-bombardment. Results Typical non-decay-corrected yields of [18F]FCH prepared using this method were 91 mCi (7% non-decay corrected based upon ~1.3 Ci [18F]fluoride), and doses passed all other quality control (QC) tests. Conclusion A one-pot liquid-phase synthesis of [18F]FCH has been developed. Doses contain extremely low levels of residual DMAE (31.6 μg / 10 mL dose or ~3 ppm) and passed all other requisite QC testing, confirming their suitability for use in clinical imaging studies. PMID:23665261

  16. Fe3O4@ionic liquid@methyl orange nanoparticles as a novel nano-adsorbent for magnetic solid-phase extraction of polycyclic aromatic hydrocarbons in environmental water samples.

    PubMed

    Liu, Xiaofei; Lu, Xin; Huang, Yong; Liu, Chengwei; Zhao, Shulin

    2014-02-01

    A novel nano-adsorbent, Fe3O4@ionic liquid@methyl orange nanoparticles (Fe3O4@IL@MO NPs), was prepared for magnetic solid-phase extraction (MSPE) of polycyclic aromatic hydrocarbons (PAHs) in environmental water samples. The Fe3O4@IL@MO NPs were synthesized by self-assembly of the ionic liquid 1-octadecyl-3-methylimidazolium bromide (C18mimBr) and methyl orange (MO) onto the surface of Fe3O4 silica magnetic nanoparticles, as confirmed by infrared spectroscopy, ultraviolet-visible spectroscopy and superconducting quantum interface device magnetometer. The extraction performance of Fe3O4@IL@MO NPs as a nano-adsorbent was evaluated by using five PAHs, fluorene (FLu), anthracene (AnT), pyrene (Pyr), benzo(a)anthracene (BaA) and benzo(a)pyrene (BaP) as model analytes. Under the optimum conditions, detection limits in the range of 0.1-2 ng/L were obtained by high performance liquid chromatography-fluorescence detection (HPLC-FLD). This method has been successfully applied for the determination of PAHs in environmental water samples by using the MSPE-HPLC-FLD. The recoveries for the five PAHs tested in spiked real water samples were in the range of 80.4-104.0% with relative standard deviations ranging from 2.3 to 4.9%. © 2013 Published by Elsevier B.V.

  17. Determination of nanomolar chromate in drinking water with solid phase extraction and a portable spectrophotometer.

    PubMed

    Ma, Jian; Yang, Bo; Byrne, Robert H

    2012-06-15

    Determination of chromate at low concentration levels in drinking water is an important analytical objective for both human health and environmental science. Here we report the use of solid phase extraction (SPE) in combination with a custom-made portable light-emitting diode (LED) spectrophotometer to achieve detection of chromate in the field at nanomolar levels. The measurement chemistry is based on a highly selective reaction between 1,5-diphenylcarbazide (DPC) and chromate under acidic conditions. The Cr-DPC complex formed in the reaction can be extracted on a commercial C18 SPE cartridge. Concentrated Cr-DPC is subsequently eluted with methanol and detected by spectrophotometry. Optimization of analytical conditions involved investigation of reagent compositions and concentrations, eluent type, flow rate (sample loading), sample volume, and stability of the SPE cartridge. Under optimized conditions, detection limits are on the order of 3 nM. Only 50 mL of sample is required for an analysis, and total analysis time is around 10 min. The targeted analytical range of 0-500 nM can be easily extended by changing the sample volume. Compared to previous SPE-based spectrophotometric methods, this analytical procedure offers the benefits of improved sensitivity, reduced sample consumption, shorter analysis time, greater operational convenience, and lower cost. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. Residual determination and risk assessment of buprofezin in plum (Prunus domestica) grown in open-field conditions following the application of three different formulations.

    PubMed

    Kabir, Md Humayun; Abd El-Aty, A M; Kim, Sung-Woo; Lee, Han Sol; Rahman, Md Musfiqur; Lee, Young-Jun; Chung, Hyung Suk; Lieu, Truong; Choi, Jeong-Heui; Shin, Ho-Chul; Im, Geon-Jae; Hong, Su Myeong; Shim, Jae-Han

    2016-11-01

    This study was conducted to characterize the residual level and perform a risk assessment on buprofezin formulated as an emulsifiable concentrate, wettable powder, and suspension concentrate over various treatment schedules in plum (Prunus domestica). The samples were extracted with an AOAC quick, easy, cheap, effective, rugged, and safe, 'QuEChERS', method after major modifications. As intrinsic interferences were observed in blank plum samples following dispersive-solid phase extraction (consisting of primary secondary amine and C 18 sorbents), amino cartridges were used for solid-phase extraction. Analysis was carried out using liquid chromatography with diode array detection and confirmed by liquid chromatography-tandem mass spectrometry. The method showed excellent linearity with determination coefficient (R 2  = 1) and satisfactory recoveries (at two spiking levels, 0.5 and 2.5 mg/kg) between 90.98 and 94.74% with relative standard deviation (RSD) ≤8%. The limit of quantification (0.05 mg/kg) was considerably lower than the maximum residue limit (2 mg/kg) set by the Codex Alimentarius. Absolute residue levels for emulsifiable concentrates were highest, perhaps owing to the dilution rate and adjuvant. Notably, all formulation residues were lower than the maximum residue limit, and safety data proved that the fruits are safe for consumers. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  19. Sequential injection-bead injection-lab-on-valve coupled to high-performance liquid chromatography for online renewable micro-solid-phase extraction of carbamate residues in food and environmental samples.

    PubMed

    Vichapong, Jitlada; Burakham, Rodjana; Srijaranai, Supalax; Grudpan, Kate

    2011-07-01

    A sequential injection-bead injection-lab-on-valve system was hyphenated to HPLC for online renewable micro-solid-phase extraction of carbamate insecticides. The carbamates studied were isoprocarb, methomyl, carbaryl, carbofuran, methiocarb, promecarb, and propoxur. LiChroprep(®) RP-18 beads (25-40 μm) were employed as renewable sorbent packing in a microcolumn situated inside the LOV platform mounted above the multiposition valve of the sequential injection system. The analytes sorbed by the microcolumn were eluted using 80% acetonitrile in 0.1% acetic acid before online introduction to the HPLC system. Separation was performed on an Atlantis C-18 column (4.6 × 150 mm, 5 μm) utilizing gradient elution with a flow rate of 1.0 mL/min and a detection wavelength at 270 nm. The sequential injection system offers the means of performing automated handling of sample preconcentration and matrix removal. The enrichment factors ranged between 20 and 125, leading to limits of detection (LODs) in the range of 1-20 μg/L. Good reproducibility was obtained with relative standard deviations of <0.7 and 5.4% for retention time and peak area, respectively. The developed method has been successfully applied to the determination of carbamate residues in fruit, vegetable, and water samples. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Determination of emamectin benzoate in medicated fish feed.

    PubMed

    Farer, L J; Hayes, J; Rosen, J; Knight, P

    1999-01-01

    A method was developed to quantitate emamectin benzoate in fish feed at levels between 5 and 15 ppm. The active ingredient is extracted from 20 g medicated feed into aqueous-methanolic solvent by overnight shaking. A solid-phase extraction procedure using a 2 g C18 cartridge is then used to concentrate the active residue and remove interfering matrix components. The extracted drug and internal standard are eluted from the cartridge, evaporated to dryness, and reconstituted in methanol. A control feed sample and fortified control working standard are simultaneously prepared. Remaining interferences and sample analysis are further separated on a gradient liquid chromatographic system. Recovery of emamectin benzoate from fortified feeds ranged from 97 to 100%, with a coefficient of variation (CV) of 1.2%. Determination of emamectin benzoate in medicated feeds resulted in CVs ranging from 2.3 to 4.2% and recoveries of 88 to 98% of label claim.

  1. Dicationic polymeric ionic-liquid-based magnetic material as an adsorbent for the magnetic solid-phase extraction of organophosphate pesticides and polycyclic aromatic hydrocarbons.

    PubMed

    Jiang, Qiong; Liu, Qin; Chen, Qiliang; Zhao, Wenjie; Xiang, Guoqiang; He, Lijun; Jiang, Xiuming; Zhang, Shusheng

    2016-08-01

    Magnetic particles modified with a dicationic polymeric ionic liquid are described as a new adsorbent in magnetic solid-phase extraction. They were obtained through the copolymerization of a 1,8-di(3-vinylimidazolium)octane-based ionic liquid with vinyl-modified SiO2 @Fe3 O4 , and were characterized by FTIR spectroscopy, X-ray diffraction, and vibrating sample magnetometry. The modified magnetic particles are effective in the extraction of organophosphate pesticides and polycyclic aromatic hydrocarbons. Also, they can provide different extraction performance for the selected analytes including fenitrothion, parathion, fenthion, phoxim, phenanthrene, and fluoranthene, where the extraction efficiency is found to be in agreement with the hydrophobicity of analytes. Various factors influencing the extraction efficiency, such as, the amount of adsorbent, extraction, and desorption time, and type and volume of the desorption solvent, were optimized. Under the optimized conditions, a good linearity ranging from 1-100 μg/L is obtained for all analytes, except for parathion (2-200 μg/L), where the correlation coefficients varied from 0.9960 to 0.9998. The limits of detection are 0.2-0.8 μg/L, and intraday and interday relative standard deviations are 1.7-7.4% (n = 5) and 3.8-8.0% (n = 3), respectively. The magnetic solid-phase extraction combined with high-performance liquid chromatography can be applied for the detection of trace targets in real water samples with satisfactory relative recoveries and relative standard deviations. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. A rapid solid-phase extraction method for measurement of non-metabolised peripheral benzodiazepine receptor ligands, [(18)F]PBR102 and [(18)F]PBR111, in rat and primate plasma.

    PubMed

    Katsifis, Andrew; Loc'h, Christian; Henderson, David; Bourdier, Thomas; Pham, Tien; Greguric, Ivan; Lam, Peter; Callaghan, Paul; Mattner, Filomena; Eberl, Stefan; Fulham, Michael

    2011-01-01

    To develop a rapid and reliable method for estimating non-metabolised PBR ligands fluoroethoxy ([(18)F]PBR102)- and fluoropropoxy ([(18)F]PBR111)-substituted 2-(6-chloro-2-phenyl)imidazo[1,2-a]pyridine-3-yl)-N,N-diethylacetamides in plasma. Rats and baboons were imaged with PET up to 2 h postinjection of [(18)F]PBR102 and [(18)F]PBR111 under baseline conditions, after pre-blocking or displacement with PK11195. Arterial plasma samples were directly analysed by reverse-phase solid-phase extraction (RP-SPE) and RP-HPLC and by normal-phase TLC. SPE cartridges were successively washed with acetonitrile/water mixtures. SPE eluant radioactivity was measured in a γ-counter to determine the parent compound fraction and then analysed by HPLC and TLC for validation. In SPE, hydrophilic and lipophilic radiolabelled metabolites were eluted in water and 20% acetonitrile/water. All non-metabolised [(18)F]PBR102 and [(18)F]PBR111 were in SPE acetonitrile fraction as confirmed by HPLC and TLC analysis. Unchanged (%) [(18)F]PBR102 and [(18)F]PBR111 from SPE analysis in rat and baboon plasma agreed with those from HPLC and TLC analysis. In rats and baboons, the fraction of unchanged tracer followed a bi-exponential decrease, with half-lives of 7 to 10 min for the fast component and >80 min for the slow component for both tracers. Direct plasma SPE analysis of [(18)F]PBR102 and [(18)F]PBR111 can reliably estimate parent compound fraction. SPE was superior to HPLC for samples with low activity; it allows rapid and accurate metabolite analysis of a large number of plasma samples for improved estimation of metabolite-corrected input function during quantitative PET imaging studies. Crown Copyright © 2011. Published by Elsevier Inc. All rights reserved.

  3. Quantitative ionspray liquid chromatographic/tandem mass spectrometric determination of reserpine in equine plasma.

    PubMed

    Anderson, M A; Wachs, T; Henion, J D

    1997-02-01

    A method based on ionspray liquid chromatography/tandem mass spectrometry (LC/MS/MS) was developed for the determination of reserpine in equine plasma. A comparison was made of the isolation of reserpine from plasma by liquid-liquid extraction and by solid-phase extraction. A structural analog, rescinnamine, was used as the internal standard. The reconstituted extracts were analyzed by ionspray LC/MS/MS in the selected reaction monitoring (SRM) mode. The calibration graph for reserpine extracted from equine plasma obtained using liquid-liquid extraction was linear from 10 to 5000 pg ml-1 and that using solid-phase extraction from 100 to 5000 pg ml-1. The lower level of quantitation (LLQ) using liquid-liquid and solid-phase extraction was 50 and 200 pg ml-1, respectively. The lower level of detection for reserpine by LC/MS/MS was 10 pg ml-1. The intra-assay accuracy did not exceed 13% for liquid-liquid and 12% for solid-phase extraction. The recoveries for the LLQ were 68% for liquid-liquid and 58% for solid-phase extraction.

  4. Hollow mesoporous structured molecularly imprinted polymer as adsorbent in pipette-tip solid-phase extraction for the determination of antiretrovirals from plasma of HIV-infected patients.

    PubMed

    Simões, Nathália Soares; de Oliveira, Hanna Leijoto; da Silva, Ricky Cássio Santos; Teixeira, Leila Suleimara; Sales, Thaís Lorenna Souza; de Castro, Whocely Victor; de Paiva, Maria José Nunes; Sanches, Cristina; Borges, Keyller Bastos

    2018-05-17

    In this work a hollow mesoporous structured molecularly imprinted polymer was synthetized and used as adsorbent in pipette-tip solid-phase extraction for the determination of lamivudine (3TC), zidovudine (AZT) and efavirenz (EFZ) from plasma of human immunodeficiency virus (HIV) infected patients by high-performance liquid chromatography (HPLC). All parameters that influence the recovery of the pipette tip based on hollow mesoporous molecularly imprinted polymer solid-phase extraction (PT-HM-MIP-SPE) method were systematically studied and discussed in detail. The adsorbent material was prepared using methacrylic acid and 4-vinylpyridine as functional monomers, ethylene glycol dimethacrylate as crosslinker, acetonitrile as solvent, 4,4'-azobis(4-cyanovaleric acid) as radical initiator, benzalkonium chloride as surfactant), 3TC, and AZT as templates. The simultaneous separation of 3TC, AZT and EFZ by HPLC-UV was performed using a Gemini C18 Phenomenexࣨ column (250 mm × 4.6 mm, 5 μm) and mobile phase consisting of acetonitrile: water pH 3.2 (68:32, v/v), flow rate of 1.0 mL min -1 and λ = 260 nm. The method was linear over the concentration range from 0.25 to 10 μg mL -1 for 3TC and EFZ, and 0.05 to 2.0 μg mL -1 for AZT, with correlation coefficients larger than 0.99 for all analytes. Recovery ± relative standard deviations (RSDs %) were 41.99±2.38 %, 82.29±1.63 %, and 83.72±7.52 % for 3TC, AZT, and EFZ, respectively. The RSDs and relative errors (REs) were lower than 15 % for intra and interday assays. The method has been successfully applied for monitoring HIV-infected patients outside the therapeutic dosage.2 This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  5. Simultaneous analysis of gemfibrozil, morphine, and its two active metabolites in different mouse brain structures using solid-phase extraction with ultra-high performance liquid chromatography and tandem mass spectrometry with a deuterated internal standard.

    PubMed

    Yang, Zizhao; Wang, Lu; Xu, Mingcheng; Gu, Jingkai; Yu, Lushan; Zeng, Su

    2016-06-01

    A rapid and sensitive bioassay was established and validated to simultaneously determine gemfibrozil, morphine, morphine-3β-glucuronide, and morphine-6β-glucuronide in mouse cerebrum, epencephalon, and hippocampus based on ultra-high performance liquid chromatography and tandem mass spectrometry. The deuterated internal standard, M6G-d3, was mixed with the prepared samples at 10 ng/mL as the final concentration. The samples were transferred into the C18 solid-phase extraction columns with gradient elution for solid-phase extraction. The mobile phase consisted of methanol and 0.05% formic acid (pH 3.2). Multiple reaction monitoring has been applied to analyze gemfibrozil (m/z 249.0 → 121.0) in anion mode, and M6G-d3 (m/z 465.1 → 289.1), morphine (m/z 286.0 → 200.9), and M3G and M6G (m/z 462.1 → 286.1) in the positive ion mode. The method has a linear calibration range from 0.05 to 10 ng for gemfibrozil, morphine, and M3G and M6G with correlation coefficients >0.993. The lower limit of quantitation for all four analytes was 0.05 ng/mL, relative standard deviation of intra- and interday precision was less than 10.5%, and the relative error of accuracy was from -8.2 to 8.3% at low, medium, and high concentrations for all the analytes. In conclusion, gemfibrozil can influence the morphine antinociception after coronary heart disease induced chronic angina by the change in one of morphine metabolites', M3G, distribution in mouse brain. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Performance and stability of low-cost dye-sensitized solar cell based crude and pre-concentrated anthocyanins: Combined experimental and DFT/TDDFT study

    NASA Astrophysics Data System (ADS)

    Chaiamornnugool, Phrompak; Tontapha, Sarawut; Phatchana, Ratchanee; Ratchapolthavisin, Nattawat; Kanokmedhakul, Somdej; Sang-aroon, Wichien; Amornkitbamrung, Vittaya

    2017-01-01

    The low cost DSSCs utilized by crude and pre-concentrated anthocyanins extracted from six anthocyanin-rich samples including mangosteen pericarp, roselle, red cabbage, Thai berry, black rice and blue pea were fabricated. Their photo-to-current conversion efficiencies and stability were examined. Pre-concentrated extracts were obtained by solid phase extraction (SPE) using C18 cartridge. The results obviously showed that all pre-concentrated extracts performed on photovoltaic performances in DSSCs better than crude extracts except for mangosteen pericarp. The DSSC sensitized by pre-concentrated anthocyanin from roselle and red cabbage showed maximum current efficiency η = 0.71% while DSSC sensitized by crude anthocyanin from mangosteen pericarp reached maximum efficiency η = 0.97%. In addition, pre-concentrated extract based cells possess more stability than those of crude extract based cells. This indicates that pre-concentration of anthocyanin via SPE method is very effective for DSSCs based on good photovoltaic performance and stability. The DFT/TDDFT calculations of electronic and photoelectrochemical properties of the major anthocyanins found in the samples are employed to support the experimental results.

  7. Unambiguous detection of astaxanthin and astaxanthin fatty acid esters in krill (Euphausia superba Dana).

    PubMed

    Grynbaum, Marc David; Hentschel, Petra; Putzbach, Karsten; Rehbein, Jens; Krucker, Manfred; Nicholson, Graeme; Albert, Klaus

    2005-09-01

    HPLC atmospheric pressure chemical ionization (APCI)/MS, GC MS, HPLC diode array detection (DAD), and NMR were used for the identification of astaxanthin and astaxanthin fatty acid esters in krill (Euphausia superba Dana). Matrix solid phase dispersion was applied for the extraction of the carotenoids. This gentle and expeditious extraction technique for solid and viscous samples leads to distinct higher enrichment rates than the conventional liquid-liquid extraction. The chromatographic separation was achieved employing a C30 RP column that allows the separation of shape-constrained geometrical isomers. A methanol/tert-butylmethyl ether/water gradient was applied. (all-E) Astaxanthin and the geometrical isomers were identified by HPLC APCI/MS, by coelution with isomerized authentical standard, by UV spectroscopy (DAD), and three isomers were unambiguously assigned by microcoil NMR spectroscopy. In this method, microcoils are transversally aligned to the magnetic field and have an increased sensitivity compared to the conventional double-saddle Helmholtz coils, thus enabling the measurement on small samples. The carotenol fatty acid esters were saponified enzymatically with Lipase type VII from Candida rugosa. The fatty acids were detected by GC MS after transesterification, but also without previous derivatization by HPLC APCI/MS. C14:0, C16:0, C16:1, C18:1, C20:0, C20:5, and C22:6 were found in astaxanthin monoesters and in astaxanthin diesters. (all-E) Astaxanthin was identified as the main isomer in six fatty acid ester fractions by NMR. Quantitation was carried out by the method of internal standard. (13-cis) Astaxanthin (70 microg/g), 542 microg/g (all-E) astaxanthin, 36 microg/g unidentified astaxanthin isomer, 62 microg/g (9-cis) astaxanthin, and 7842 microg/g astaxanthin fatty acid esters were found.

  8. Ultra-high-pressure liquid chromatography-tandem mass spectrometry method for the determination of alkylphenols in soil.

    PubMed

    Wang, Jing; Pan, Hefang; Liu, Zhengzheng; Ge, Fei

    2009-03-20

    A novel method has been developed for the determination of alkylphenols in soil by ultra-high-pressure liquid chromatography employing small particle sizes, combined with tandem mass spectrometry. Soil samples were extracted with pressurized liquid extraction (PLE) and then cleaned with solid-phase extraction (SPE). The extracts were separated on C18 column (1.7 microm, 50 mm x 2.1mm) with a gradient elution and a mobile phase consisting of water and acetonitrile, and then detected by an electrospray ionization tandem mass spectrometry in negative ion mode with multiple reaction monitoring (MRM). Compared with traditional liquid chromatography, it took ultra-high-pressure liquid chromatography much less time to analyze alkylphenols. Additionally, the ultra-high-pressure liquid chromatography/tandem mass spectrometry method produces satisfactory reliability, sensitivity, and accuracy. The average recoveries of the three target analytes were 74.0-103.4%, with the RSD<15%. The calibration curves for alkylphenols were linear within the range of 0.01-0.4 microg/ml, with the correlation coefficients greater than 0.99. When 10 g soil sample was used for analysis, the limits of quantification (LOQs) of the three alkylphenols were all 1.0 microg/kg.

  9. Simultaneous determination of a variety of endocrine disrupting compounds in carrot, lettuce and amended soil by means of focused ultrasonic solid-liquid extraction and dispersive solid-phase extraction as simplified clean-up strategy.

    PubMed

    Mijangos, L; Bizkarguenaga, E; Prieto, A; Fernández, L A; Zuloaga, O

    2015-04-10

    The present study is focused on the development of an analytical method based on focused ultrasonic solid-liquid extraction (FUSLE) followed by dispersive solid-phase extraction (dSPE) clean-up and liquid chromatography-triple quadrupole tandem mass spectrometry (LC-MS/MS) optimised for the simultaneous analysis of certain endocrine disrupting compounds (EDCs), including alkylphenols (APs), bisphenol A (BPA), triclosan (TCS) and several hormones and sterols in vegetables (lettuce and carrot) and amended soil samples. Different variables affecting the chromatographic separation, the electrospray ionisation and mass spectrometric detection were optimised in order to improve the sensitivity of the separation and detection steps. Under the optimised extraction conditions (sonication of 5min at 33% of power with pulse times on of 0.8s and pulse times off of 0.2s in 10mL of n-hexane:acetone (30:70, v:v) mixture using an ice bath), different dSPE clean-up sorbents, such as Florisil, Envi-Carb, primary-secondary amine bonded silica (PSA) and C18, or combinations of them were evaluated for FUSLE extracts before LC-MS/MS. Apparent recoveries and precision in terms of relative standard deviation (RSDs %) of the method were determined at two different fortification levels (according to the matrix and the analyte) and values in the 70-130% and 2-27% ranges, respectively, were obtained for most of the target analytes and matrices. Matrix-matched calibration approach and the use of labelled standards as surrogates were needed for the properly quantification of most analytes and matrices. Method detection limits (MDLs), estimated with fortified samples, in the ranges of 0.1-100ng/g for carrot, 0.2-152ng/g for lettuce and 0.9-31ng/g for amended soil were obtained. The developed methodology was applied to the analysis of 11 EDCs in both real vegetable bought in a local market and in compost (from a local wastewater treatment plant, WWTP) amended soil samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Simultaneous determination of ezetimibe and its glucuronide metabolite in human plasma by solid phase extraction and liquid chromatography-tandem mass spectrometry.

    PubMed

    Guo, Lin; Wang, Meng-meng; He, Min; Qiu, Fu-rong; Jiang, Jian

    2015-04-01

    A liquid chromatography-tandem mass spectrometry method (LC-MS/MS) was developed to quantify ezetimibe (EZM) and its major glucuronide (ezetimibe glucuronide, EZM-G) in human plasma simultaneously. The analytes were purified by solid phase extraction (SPE) without hydrolysis. Separation of the analytes was achieved using acetonitrile-water (0.08% formic acid) (70:30, v/v) as the mobile phase at a flow rate of 0.8 mL/min on an Agilent Extend C18 column. The analytes were detected by LC-MS/MS using negative ionization in multiple reaction monitoring (MRM) mode. The mass transition pairs of m/z 408.4→271.0 and m/z 584.5→271.0 were used to detect EZM and EZM-G, respectively. The analytical method was linear over the concentration range of 0.1-20 ng/mL for EZM and 0.5-200 ng/mL for EZM-G. Within- and between-run precision for EZM was no more than 8.6% and 12.8%; and for EZM-G was no more than 9.0% and 8.7%, respectively. This method was reproducible and reliable, and was successfully used to analyze human plasma samples for application in a bioequivalence study. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Validated LC-MS-MS Method for Multiresidual Analysis of 13 Illicit Phenethylamines in Amniotic Fluid.

    PubMed

    Burrai, Lucia; Nieddu, Maria; Carta, Antonio; Trignano, Claudia; Sanna, Raimonda; Boatto, Gianpiero

    2016-04-01

    A multi-residue analytical method was developed for the determination in amniotic fluid (AF) of 13 illicit phenethylamines, including 12 compounds never investigated in this matrix before. Samples were subject to solid-phase extraction using; hydrophilic-lipophilic balance cartridges which gave good recoveries and low matrix effects on analysis of the extracts. The quantification was performed by liquid chromatography electrospray tandem mass spectrometry. The water-acetonitrile mobile phase containing 0.1% formic acid, used with a C18 reversed phase column, provided adequate separation, resolution and signal-to-noise ratio for the analytes and the internal standard. The final optimized method was validated according to international guidelines. A monitoring campaign to assess fetal exposure to these 13 substances of abuse has been performed on AF test samples obtained from pregnant women. All mothers (n = 194) reported no use of drugs of abuse during pregnancy, and this was confirmed by the analytical data. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Rapid determination of the volatile components in tobacco by ultrasound-microwave synergistic extraction coupled to headspace solid-phase microextraction with gas chromatography-mass spectrometry.

    PubMed

    Yang, Yanqin; Chu, Guohai; Zhou, Guojun; Jiang, Jian; Yuan, Kailong; Pan, Yuanjiang; Song, Zhiyu; Li, Zuguang; Xia, Qian; Lu, Xinbo; Xiao, Weiqiang

    2016-03-01

    An ultrasound-microwave synergistic extraction coupled to headspace solid-phase microextraction was first employed to determine the volatile components in tobacco samples. The method combined the advantages of ultrasound, microwave, and headspace solid-phase microextraction. The extraction, separation, and enrichment were performed in a single step, which could greatly simplify the operation and reduce the whole pretreatment time. In the developed method, several experimental parameters, such as fiber type, ultrasound power, and irradiation time, were optimized to improve sampling efficiency. Under the optimal conditions, there were 37, 36, 34, and 36 components identified in tobacco from Guizhou, Hunan, Yunnan, and Zimbabwe, respectively, including esters, heterocycles, alkanes, ketones, terpenoids, acids, phenols, and alcohols. The compound types were roughly the same while the contents were varied from different origins due to the disparity of their growing conditions, such as soil, water, and climate. In addition, the ultrasound-microwave synergistic extraction coupled to headspace solid-phase microextraction method was compared with the microwave-assisted extraction coupled to headspace solid-phase microextraction and headspace solid-phase microextraction methods. More types of volatile components were obtained by using the ultrasound-microwave synergistic extraction coupled to headspace solid-phase microextraction method, moreover, the contents were high. The results indicated that the ultrasound-microwave synergistic extraction coupled to headspace solid-phase microextraction technique was a simple, time-saving and highly efficient approach, which was especially suitable for analysis of the volatile components in tobacco. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Determination of phenolic xenoestrogens in water by liquid chromatography with coulometric-array detection.

    PubMed

    Inoue, Koichi; Yoshie, Yuriko; Kondo, Sachiko; Yoshimura, Yoshihiro; Nakazawa, Hiroyuki

    2002-02-08

    A sensitive method for the simultaneous determination of phenolic xenoestrogens such as bisphenol A, 2,4-dichlorophenol, 4-tert,-butylphenol, 4-n2-pentylphenol, 4-n-hexylphenol, 4-n-heptylphenol, 4-octylphenol, 4-nonylphenol was developed using reversed-phase LC and coulometric-array detection. Stepwise gradient elution with phosphoric acid in water-acetonitrile was used. The calibration curves were linear in the range of 5.0 (or 10.0)-1000 ng ml(-1) with correlation coefficients of 0.9978-0.9999, the limits of detection were 0.01-0.02 ng ml(-1). Sample clean-up was performed by solid-phase extraction (SPE) using 3M Empore extraction disks. Three commercial sorbents, C18, SDB-XD (styrene-divinylbenzene polymer) and SDB-RPS (sulfonated styrene-divinylbenzene polymer) were compared. The highest recoveries were obtained with SDB-RPS. They were above 70% with a relative standard deviation of less than 15%. The proposed method was applied to the determination of phenolic xenoestrogens in various water samples.

  14. Analytical determination of virginiamycin drug residues in edible porcine tissues by LC-MS with confirmation by LC-MS/MS.

    PubMed

    Boison, Joe; Lee, Stephen; Gedir, Ron

    2009-01-01

    A liquid chromatographic-mass spectrometric (LC-MS) method was developed and validated for the determination and confirmation of virginiamycin (VMY) M1 residues in porcine liver, kidney, and muscle tissues at concentrations > or =2 ng/g. Porcine liver, kidney, or muscle tissue is homogenized with methanol-acetonitrile. After centrifugation, the supernatant is diluted with phosphate buffer and cleaned up on a C18 solid-phase extraction cartridge. VMY in the eluate is partitioned into chloroform and the aqueous upper layer is removed by aspiration. After evaporating the chloroform in the residual mixture to dryness, the dried extract is reconstituted in mobile phase and VMY is quantified by LC-MS. Any samples eliciting quantifiable levels of VMY M1 (i.e., at concentrations > or =2 ng/g) are subjected to confirmatory analysis by LC-MSIMS. VMY S1, a minor component of the VMY complex, is monitored but not quantified or confirmed.

  15. Determination of tilmicosin residues in chicken, cattle, swine, and sheep tissues by liquid chromatography.

    PubMed

    Stobba-Wiley, C M; Chang, J P; Elsbury, D T; Moran, J W; Turner, J M; Readnour, R S; Stobba-Wiley, C M; Chang, J P; Elsbury, D T; Moran, J W; Turner, J M; Readnour, R S

    2000-01-01

    A method was developed and validated for determination and quantitation of tilmicosin residues in swine, cattle, and sheep edible tissues, as well as chicken fat, skin, and muscle over a concentration range of 0.025 microg/g-20 microg/g. For chicken kidney and liver, the method was validated over a range of 0.060 microg/g-20 microg/g. The tissue sample was extracted with methanol and a C18 cartridge was used for solid-phase extraction cleanup. A reversed-phase gradient liquid chromatographic method with detection at 280 nm was used to separate the tilmicosin from matrix components in 30 min run time. The limit of quantitation (LOQ) of the method was 0.025 microg/g for all tested tissues except chicken kidney and liver, for which the LOQ was 0.06 microg/g. Average recoveries for tissue samples ranged from 73 to 98%. Relative standard deviation values ranged from 0.6 to 14.7%.

  16. Sensitive analysis of blonanserin, a novel antipsychotic agent, in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Ogawa, Tadashi; Hattori, Hideki; Kaneko, Rina; Ito, Kenjiro; Iwai, Masayo; Mizutani, Yoko; Arinobu, Tetsuya; Ishii, Akira; Suzuki, Osamu; Seno, Hiroshi

    2010-01-01

    A rapid and sensitive method for analysis of blonanserin in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry is presented. After pretreatment of a plasma sample by solid-phase extraction, blonanserin was analyzed by the system with a C(18) column. This method gave satisfactory recovery rates, reproducibility, and good linearity of calibration curve in the range of 0.01-10.0 ng/mL for quality control samples spiked with blonanserin. The detection limit was as low as 1 pg/mL. This method seems very useful in forensic and clinical toxicology and pharmacokinetic studies.

  17. A simple and sensitive quantitation of N,N-dimethyltryptamine by gas chromatography with surface ionization detection.

    PubMed

    Ishii, A; Seno, H; Suzuki, O; Hattori, H; Kumazawa, T

    1997-01-01

    A simple and sensitive method for determination of N,N-dimethyltryptamine (DMT) by gas chromatography (GC) with surface ionization detection (SID) is presented. Whole blood or urine, containing DMT and gramine (internal standard), was subjected to solid-phase extraction with a Sep-Pak C18 cartridge before analysis by GC-SID. The calibration curve was linear in the DMT range of 1.25-20 ng/mL blood or urine. The detection limit of DMT was about 0.5 ng/mL (10 pg on-column). The recovery of both DMT and gramine spiked in biological fluids was above 86%.

  18. Solid phase extraction of amoxicillin using dibenzo-18-crown-6 modified magnetic-multiwalled carbon nanotubes prior to its spectrophotometric determination.

    PubMed

    Ahmadi, Mazaher; Madrakian, Tayyebeh; Afkhami, Abbas

    2016-01-01

    This work reports on a method for selective extraction and sensitive determination of amoxicillin drug (AMX). The method is based on solid phase extraction of AMX by a novel modified magnetic nanoadsorbent prior to spectrophotometric determination of AMX using a procedure based on formation a colored azo-derivative of the investigated drug. The nanoadsorbent has been synthesized by modification of magnetic-multiwalled carbon nanotube with dibenzo-18-crown-6 moieties. The synthesized nanoparticles were characterized using TEM, XRD and FT-IR measurements. At the next step, various factors that could potentially affect adsorption and desorption efficiencies of AMX, have been optimized. The results showed that under the optimized conditions, sensitive and selective determination of the investigated drug in concentration range of 5.0-1000.0 ng mL(-1) with the limit of detection of 3.0 ng mL(-1) was achievable. Furthermore, the real sample analysis (i.e. amoxicillin capsules and human urine samples) results indicated that a reliable promising candidate method has been developed for the determination of AMX in the investigated real samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Liquid chromatography tandem mass spectrometry method using solid-phase extraction and bead-beating-assisted matrix solid-phase dispersion to quantify the fungicide tebuconazole in controlled frog exposure study: analysis of water and animal tissue.

    PubMed

    Hansen, Martin; Poulsen, Rikke; Luong, Xuan; Sedlak, David L; Hayes, Tyrone

    2014-11-01

    This paper presents the development, optimization, and validation of a LC-MS/MS methodology to determine the concentration of the antifungal drug and fungicide tebuconazole in a controlled exposure study of African clawed frogs (Xenopus laevis). The method is validated on animal tank water and on tissue from exposed and non-exposed adult X. laevis. Using solid-phase extraction (SPE), the analytical method allows for quantification of tebuconazole at concentrations as low as 3.89 pg mL(-1) in 10 mL water samples. Using bead-beating-assisted matrix solid-phase dispersion (MSPD), it was possible to quantify tebuconazole down to 0.63 pg mg(-1) wet weight liver using 150 mg tissue. The deuterated analogue of tebuconazole was used as internal standard, and ensured method accuracy in the range 80.6-99.7% for water and 68.1-109% for tissue samples. The developed method was successfully applied in a 4-week X. laevis repeated-exposure study, revealing high levels of tebuconazole residues in adipose and liver tissue, and with experimental bioconcentration factors up to 18,244 L kg(-1).

  20. Quantitative assessment of groundwater quality using a biological indicator: some preliminary observations.

    PubMed

    Pfeil, R M; Venkat, J A; Plimmer, J R; Sham, S; Davis, K; Nair, P P

    1994-02-01

    The genotoxicity of groundwater was evaluated, using a novel application of the SOS microplate assay (SOSMA). Organic residues were extracted from groundwater samples from Maryland, Pennsylvania, and Delaware by using C-18 bonded silica solid phase extraction tubes. Total organic carbon content (TOC) of water samples was also determined. The genotoxicity of the extracts was determined by the SOSMA. Relative activity (RA) as determined by the SOSMA is a quantitative measure of genotoxicity based on a comparison to the activity of the mutagen, 4-nitroquinoline oxide. Low levels of RA (about 2x background) were detected in waters from sites within these states. There was considerable temporal and spatial variation in the observed RA, but no definite patterns were observed in the variation. Between sampling sites there was a positive correlation between RA and TOC; however, this relationship appeared to be reversed occasionally within a sampling site. The extraction and bioassay methods provide an easy and relatively inexpensive means of determining water quality.

  1. Development and validation of a simple solid-phase extraction method coupled with liquid chromatography-triple quadrupole tandem mass spectrometry for simultaneous determination of lincomycin, tylosin A and tylosin B in royal jelly.

    PubMed

    Zheng, Weijia; Park, Jin-A; Abd El-Aty, A M; Kim, Seong-Kwan; Cho, Sang-Hyun; Choi, Jeong-Min; Warda, Mohamad; Wang, Jing; Shim, Jae-Han; Shin, Ho-Chul

    2018-04-01

    We have developed an analytical method for the determination of lincomycin, tylosin A and tylosin B residues in royal jelly using liquid chromatography-triple quadrupole tandem mass spectrometry analysis. For extraction and purification, we employed 1% trifluoroacetic acid and 0.1 m Na 2 EDTA solutions along with an Oasis HLB cartridge. The target antibiotics were well separated in a Kinetex EVO C 18 reversed-phase analytical column using a combination of 0.1% formate acid in ultrapure water (A) and acetonitrile (B) as the mobile phase. Good linearity was achieved over the tested concentration range (5-50 μg/kg) in matrix-matched standard calibration. The coefficients of determination (R 2 ) were 0.9933, 0.9933 and 0.996, for tylosin A, tylosin B and lincomycin, respectively. Fortified royal jelly spiked with three different concentrations of the tested antibiotics (5, 10 and 20 μg/kg) yielded recoveries in the range 80.94-109.26% with relative standard deviations ≤4%. The proposed method was applied to monitor 11 brand of royal jelly collected from domestic markets and an imported brand from New Zealand; all the samples tested negative for lincomycin, tylosin A and tylosin B residues. In conclusion, 1% trifluoroacetic acid and 0.1 m Na 2 EDTA aqueous solvents combined with solid-phase extraction could effectively complete the sample preparation process for royal jelly before analysis. The developed approach can be applied for a routine analysis of lincomycin, tylosin A and tylosin B residues in royal jelly. Copyright © 2017 John Wiley & Sons, Ltd.

  2. Optimization of Microwave-Assisted Extraction Conditions for Five Major Bioactive Compounds from Flos Sophorae Immaturus (Cultivars of Sophora japonica L.) Using Response Surface Methodology.

    PubMed

    Liu, Jin-Liang; Li, Long-Yun; He, Guang-Hua

    2016-03-02

    Microwave-assisted extraction was applied to extract rutin; quercetin; genistein; kaempferol; and isorhamnetin from Flos Sophorae Immaturus. Six independent variables; namely; solvent type; particle size; extraction frequency; liquid-to-solid ratio; microwave power; and extraction time were examined. Response surface methodology using a central composite design was employed to optimize experimental conditions (liquid-to-solid ratio; microwave power; and extraction time) based on the results of single factor tests to extract the five major components in Flos Sophorae Immaturus. Experimental data were fitted to a second-order polynomial equation using multiple regression analysis. Data were also analyzed using appropriate statistical methods. Optimal extraction conditions were as follows: extraction solvent; 100% methanol; particle size; 100 mesh; extraction frequency; 1; liquid-to-solid ratio; 50:1; microwave power; 287 W; and extraction time; 80 s. A rapid and sensitive ultra-high performance liquid chromatography method coupled with electrospray ionization quadrupole time-of-flight tandem mass spectrometry (EIS-Q-TOF MS/MS) was developed and validated for the simultaneous determination of rutin; quercetin; genistein; kaempferol; and isorhamnetin in Flos Sophorae Immaturus. Chromatographic separation was accomplished on a Kinetex C18 column (100 mm × 2.1 mm; 2.6 μm) at 40 °C within 5 min. The mobile phase consisted of 0.1% aqueous formic acid and acetonitrile (71:29; v/v). Isocratic elution was carried out at a flow rate of 0.35 mL/min. The constituents of Flos Sophorae Immaturus were simultaneously identified by EIS-Q-TOF MS/MS in multiple reaction monitoring mode. During quantitative analysis; all of the calibration curves showed good linear relationships (R² > 0.999) within the tested ranges; and mean recoveries ranged from 96.0216% to 101.0601%. The precision determined through intra- and inter-day studies showed an RSD% of <2.833%. These results demonstrate that the developed method is accurate and effective and could be readily utilized for the comprehensive quality control of Flos Sophorae Immaturus.

  3. Determination of phosphonoformate (foscarnet) in calf and human serum by automated solid-phase extraction and high-performance liquid chromatography with amperometric detection.

    PubMed

    Ba, B B; Corniot, A G; Ducint, D; Breilh, D; Grellet, J; Saux, M C

    1999-03-05

    An isocratic high-performance liquid chromatographic method with automated solid-phase extraction has been developed to determine foscarnet in calf and human serums. Extraction was performed with an anion exchanger, SAX, from which the analyte was eluted with a 50 mM potassium pyrophosphate buffer, pH 8.4. The mobile phase consisted of methanol-40 mM disodium hydrogenphosphate, pH 7.6 containing 0.25 mM tetrahexylammonium hydrogensulphate (25:75, v/v). The analyte was separated on a polyether ether ketone (PEEK) column 150x4.6 mm I.D. packed with Kromasil 100 C18, 5 microm. Amperometric detection allowed a quantification limit of 15 microM. The assay was linear from 15 to 240 microM. The recovery of foscarnet from calf serum ranged from 60.65+/-1.89% for 15 microM to 67.45+/-1.24% for 200 microM. The coefficient of variation was < or = 3.73% for intra-assay precision and < or =7.24% for inter-assay precision for calf serum concentrations ranged from 15 to 800 microM. For the same samples, the deviation from the nominal value ranged from -8.97% to +5.40% for same day accuracy and from -4.50% to +2.77% for day-to-day accuracy. Selectivity was satisfactory towards potential co-medications. Replacement of human serum by calf serum for calibration standards and quality control samples was validated. Automation brought more protection against biohazards and increase in productivity for routine monitoring and pharmacokinetic studies.

  4. Robust trace analysis of polar (C2-C8) perfluorinated carboxylic acids by liquid chromatography-tandem mass spectrometry: method development and application to surface water, groundwater and drinking water.

    PubMed

    Janda, Joachim; Nödler, Karsten; Brauch, Heinz-Jürgen; Zwiener, Christian; Lange, Frank T

    2018-03-19

    A simple and robust analytical method for the determination of perfluorinated carboxylic acids (PFCAs) with C 2 to C 8 chains, based on solid-phase extraction (SPE) and liquid chromatography-tandem mass spectrometry (LC-MS/MS), was developed, validated and applied to tap water, groundwater and surface water. Two stationary phases for LC (Obelisc N and Kinetex C 18 ) and two materials with weak anion-exchange properties for SPE (Strata X-AW and Oasis WAX) were evaluated. Robust separation and retention was achieved with the reversed phase column and an acidic eluent. Quantitative extraction recoveries were generally achieved for PFCAs with C > 3, but extraction efficiencies were different for the two shortest chained analytes: 36 to 114% of perfluoropropanoate (PFPrA) and 14 to 99% of trifluoroacetate (TFA) were recovered with Strata X-AW, while 93 to 103% of PFPrA and 40 to 103% of TFA were recovered with Oasis WAX. The sample pH was identified as a key parameter in the extraction process. One-step elution-filtration was introduced in the workflow, in order to remove sorbent particles and minimise sample preparation steps. Validation resulted in limits of quantification for all PFCAs between 0.6 and 26 ng/L. Precision was between 0.7 and 15% and mean recoveries ranged from 83 to 107%. In groundwater samples from sites impacted by per- and polyfluoroalkyl substances (PFASs), PFCA concentrations ranged from 0.056 to 2.2 μg/L. TFA and perfluorooctanoate were the predominant analytes. TFA, however, revealed a more ubiquitous occurrence and was found in concentrations between 0.045 and 17 μg/L in drinking water, groundwater and surface water, which were not impacted by PFASs.

  5. Determination of 1,3-dichloro-2-propanol and 3-chloro-1,2-propandiol in soy sauce by headspace derivatization solid-phase microextraction combined with gas chromatography-mass spectrometry.

    PubMed

    Lee, Maw-Rong; Chiu, Tzu-Chun; Dou, Jianpeng

    2007-05-22

    This study proposes a method for identifying 1,3-dichloro-2-propanol and 3-chloro-1,2-propandiol in aqueous matrices by using headspace on-fiber derivatization following solid-phase microextraction combined with gas chromatography-mass spectrometry. The optimized SPME experimental procedures for extracting 1,3-dichloro-2-propanol and 3-chloro-1,2-propandiol in aqueous solutions involved a 85 microm polyacrylate-coated fiber at pH 6, a sodium chloride concentration of 0.36 g mL(-1), extraction at 50 degrees C for 15 min and desorption of analytes at 260 degrees C for 3 min. Headspace derivatization was conducted in a laboratory-made design with N-methyl-N-(trimethylsilyl)-trifluoroacetamide vapor following solid-phase microextraction by using 3 microL N-methyl-N-(trimethylsilyl)-trifluoroacetamide at an oil bath temperature of 230 degrees C for 40 s. This method had good repeatability (R.S.D.s < or = 19%, n = 8) and good linearity (r2 > or = 0.9972) for ultrapure water and soy sauce samples that were spiked with two analytes. Detection limits were obtained at the ng mL(-1). The result demonstrated that headspace on-fiber derivatization following solid-phase microextraction was a simple, fast and accurate technique for identifying trace 1,3-dichloro-2-propanol and 3-chloro-1,2-propandiol in soy sauce.

  6. Molecularly imprinted-solid phase extraction combined with simultaneous derivatization and dispersive liquid-liquid microextraction for selective extraction and preconcentration of methamphetamine and ecstasy from urine samples followed by gas chromatography.

    PubMed

    Djozan, Djavanshir; Farajzadeh, Mir Ali; Sorouraddin, Saeed Mohammad; Baheri, Tahmineh

    2012-07-27

    In this study, a developed technique was reported for extraction and pre-concentration of methamphetamine (MAMP) and 3,4-methylenedioxymethamphetamine (MDMA, ecstasy) from urine samples using molecularly imprinted-solid phase extraction (MISPE) along with simultaneous derivatization and dispersive liquid-liquid microextraction (DLLME). Molecularly imprinted microspheres as sorbent in solid phase extraction (SPE) procedure were synthesized using precipitation polymerization with MAMP as the template. Aqueous solution of the target analytes was passed through MAMP-MIP cartridge and the adsorbed analytes were then eluted with methanol. The collected eluate was mixed with butylchloroformate which served as the derivatization reagent as well as the extraction solvent. The mixture was immediately injected into deionized water. After centrifugation, 1 μL of the settled organic phase was injected into gas chromatography-flame ionization detection (GC-FID) or gas chromatography-mass spectrometry (GC-MS). Various experimental parameters affecting the performance of both of the steps (MISPE and DLLME) were thoroughly investigated. The calibration graphs were linear in the ranges of 10-1500 ng mL(-1) (MAMP) and 50-1500 ng mL(-1) (MDMA), and the detection limits (LODs) were 2 and 18 ng mL(-1), respectively. The relative standard deviations (%RSDs) obtained for six repeated experiments (100 ng mL(-1) of each drug) were 5.1% and 6.8% for MAMP and MDMA, respectively. The relative recoveries obtained for the analytes in human urine samples, spiked with different levels of each drug, were within the range of 80-88%. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Coupling solid-phase extraction and enzyme-linked immunosorbent assay for ultratrace determination of herbicides in pristine water

    USGS Publications Warehouse

    Aga, D.S.; Thurman, E.M.

    1993-01-01

    Solid-phase extraction (SPE) and enzyme-linked immunosorbent assay (ELISA) were coupled for automated trace analysis of pristine water samples containing 2-chloro-4-ethylamino-6-isopropylamine-s-triazine (atrazine) and 2-chloro-2???,6???-diethyl-N-(methoxymethyl)acetanilide (alachlor). The isolation of the two herbicides on a C18-resin involved the selection of an elution solvent that both removes interfering substances and is compatible with ELISA. Ethyl acetate was selected as the elution solvent followed by a solvent exchange with methanol/water (20/80, % v/v). The SPE-ELISA method has a detection limit of 5.0 ng/L (5 ppt), >90% recovery, and a relative standard deviation of ??10%. The performance of a microtiter plate-based ELISA and a magnetic particle-based ELISA coupled to SPE was also evaluated. Although the sensitivity of the two ELISA methods was comparable, the precision using magnetic particles was improved considerably (??10% versus ??20%) because of the faster reaction kinetics provided by the magnetic particles. Finally, SPE-ELISA and isotope dilution gas chromatography/ mass spectrometry correlated well (correlation coefficient of 0.96) for lake-water samples. The SPE-ELISA method is simple and may have broader applications for the inexpensive automated analysis of other contaminants in water at trace levels.

  8. Determination of paraben preservatives in seafood using matrix solid-phase dispersion and on-line acetylation gas chromatography-mass spectrometry.

    PubMed

    Djatmika, Rosalina; Hsieh, Chih-Chung; Chen, Jhih-Ming; Ding, Wang-Hsien

    2016-11-15

    An effective method for determining four commonly detected paraben preservatives (methyl, ethyl, propyl and butyl paraben) in marketed seafood is presented. This method employs matrix solid-phase dispersion (MSPD) before identification and quantification of the paraben preservatives via on-line acetylation gas chromatography-mass spectrometry (GC-MS). Parameters affecting the extraction efficiency of MSPD were optimized through a Box-Behnken design method. Under optimal condition, 0.5-g of freeze-dried seafood was mixed with 0.5-g of anhydrous sodium sulfate, and dispersed with 1.0-g of Florisil using vortex. After that, the blend was transferred to a glass column containing 1.5-g of silica gel+C18 (w/w, 9:1), which acted as clean-up co-sorbents. Then, target analytes were eluted with 12mL of acetonitrile. The extract was then derivatized on-line in the GC injection-port through reaction with acetic anhydride, and the identity and quantity of the target analytes were determined by the GC-MS system. The limits of quantitation (LOQs) were 0.2 to 1.0ng/g (dry weight). Preliminary results showed that the total concentrations of four selected parabens ranged from 16.7 to 44.7ng/g (dry weight). Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Cold-induced aqueous acetonitrile phase separation: A salt-free way to begin quick, easy, cheap, effective, rugged, safe.

    PubMed

    Shao, Gang; Agar, Jeffrey; Giese, Roger W

    2017-07-14

    Cooling a 1:1 (v/v) solution of acetonitrile and water at -16° C is known to result in two clear phases. We will refer to this event as "cold-induced aqueous acetonitrile phase separation (CIPS)". On a molar basis, acetonitrile is 71.7% and 13.6% in the upper and lower phases, respectively, in our study. The phase separation proceeds as a descending cloud of microdroplets. At the convenient temperature (typical freezer) employed here the lower phase is rather resistant to solidification, although it emerges from the freezer as a solid if various insoluble matter is present at the outset. In a preliminary way, we replaced the initial (salting-out) step of a representative QuEChERS procedure with CIPS, applying this modified procedure ("CIPS-QuEChERS") to a homogenate of salmon (and partly to beef). Three phases resulted, where only the upper, acetonitrile-rich phase is a liquid (that is completely clear). The middle phase comprises ice and precipitated lipids, while the lower phase is the residual matrix of undissolved salmon or meat. Treating the upper phase from salmon, after isolation, with anhydrous MgSO 4 and C18-Si (typical QuEChERS dispersive solid phase extraction sorbents), and injecting into a GC-MS in a nontargeted mode, gives two-fold more preliminary hits for chemicals, and also number of spiked pesticides recovered, relative to that from a comparable QuEChERS method. In part, this is because of much higher background signals in the latter case. Further study of CIPS-QuEChERS is encouraged, including taking advantage of other QuERChERS conditions. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Direct measurement of the glucuronide conjugate of 1-hydroxypyrene in human urine by using liquid chromatography with tandem mass spectrometry.

    PubMed

    Kakimoto, Kensaku; Toriba, Akira; Ohno, Takanori; Ueno, Mariko; Kameda, Takayuki; Tang, Ning; Hayakawa, Kazuichi

    2008-05-15

    To evaluate human exposure to polycyclic aromatic hydrocarbons (PAHs), we developed a rapid, simple and sensitive method for determining 1-hydroxypyrene-glucuronide (1-OHP-G) in human urine. To improve precision, a deuterated glucuronide was used as an internal standard. The method requires only 1 mL of urine. The urine was treated with a mixed-mode anion-exchange and reversed-phase solid-phase extraction cartridge (Oasis MAX). The analytes were analyzed with a C(18) reversed-phase column with a gradient elution, followed by tandem mass spectrometry with electrospray ionization in negative ion mode. The detection limit of 1-OHP-G (corresponding to a signal-to-noise ratio of 3) was 0.13 fmol/injection. Urinary concentrations of 1-OHP-G determined by this method were strongly correlated (r(2)=0.961) with concentrations of 1-hydroxypyrene by conventional HPLC with fluorescence detection.

  11. A simple, sensitive determination of ganciclovir in infant plasma by high-performance liquid chromatography with fluorescence detection.

    PubMed

    Yoshida, Terumitsu; Takahashi, Ryohei; Imai, Koichi; Uchida, Hiroshi; Arai, Yasutoshi; Oh-ishi, Tsutomu

    2010-03-01

    This study developed a simple and sensitive method using reversed-phase high-performance liquid chromatography (HPLC) for ganciclovir (GCV) plasma concentrations in cytomegalovirus infectious infants with hearing loss. The method involves a simple protein precipitation procedure that uses no solid-phase or liquid-liquid extraction. The HPLC separation was carried out on a Cadenza CD-C(18) column (3 microm, 4.6 mm x 150 mm) with phosphate buffer (pH 2.5, 25 mM) containing 1% methanol-acetonitrile mixture (4:3, v/v) as a mobile phase at a 0.7 mL/min flow rate. GCV was detected using a fluorescence detection (lambdaex/em: 265/380 nm). The quantification limit was 0.025 microg/mL for 100 microL of plasma sample at which good intra- and inter-assay coefficient of variation values (< 4.96%) and recoveries (94.9-96.5%) were established.

  12. High-throughput screening for multi-class veterinary drug residues in animal muscle using liquid chromatography/tandem mass spectrometry with on-line solid-phase extraction.

    PubMed

    Tang, Hubert Po-On; Ho, Clare; Lai, Shirley Sau-Ling

    2006-01-01

    A rapid qualitative method using on-line column-switching liquid chromatography/tandem mass spectrometry (LC/MS/MS) was developed and validated for screening 13 target veterinary drugs: four macrolides - erythromycin A, josamycin (leucomycin A3), kitasamycin (leucomycin A5), and tylosin A; six (fluoro)quinolones - ciprofloxacin, danofloxacin, enrofloxacin, flumequine, oxolinic acid, and sarafloxacin; and lincomycin, virginiamycin M1, and trimethoprim in different animal muscles. Clindamycin, norfloxacin, nalidixic acid, oleandomycin, ormetoprim, and roxithromycin were used as the internal standards. After simple deproteination and analyte extraction of muscle samples using acetonitrile, the supernatant was subjected to on-line cleanup and direct analysis by LC/MS/MS. On-line cleanup with an extraction cartridge packed with hydrophilic-hydrophobic polymer sorbent followed by fast LC using a short C18 column resulted in a total analysis cycle of 6 min for 19 drugs. This screening method considerably reduced the time and the cost for the quantitative and confirmatory analyses. The application of a control point approach was also introduced and explained. Copyright (c) 2006 John Wiley & Sons, Ltd.

  13. Novel radiosynthesis of PET HSV-tk gene reporter probes [18F]FHPG and [18F]FHBG employing dual Sep-Pak SPE techniques.

    PubMed

    Wang, Ji-Quan; Zheng, Qi-Huang; Fei, Xiangshu; Mock, Bruce H; Hutchins, Gary D

    2003-11-17

    Positron emission tomography (PET) herpes simplex virus thymidine kinase (HSV-tk) gene reporter probes 9-[(3-[(18)F]fluoro-1-hydroxy-2-propoxy)methyl]guanine ([(18)F]FHPG) and 9-(4-[(18)F]fluoro-3-hydroxymethylbutyl)guanine ([(18)F]FHBG) were prepared by nucleophilic substitution of the appropriate tosylated precursors with [(18)F]KF/Kryptofix 2.2.2 followed by a quick deprotection reaction and purification with a simplified dual Silica Sep-Pak solid-phase extraction (SPE) method in 15-30% radiochemical yield.

  14. A validated UPLC-MS/MS method coupled with protein precipitation and ion exchange solid phase extraction for the quantitation of porcine relaxin B29 in dog plasma and its application to a pharmacokinetic study.

    PubMed

    Su, Chong; Sun, Hui; Yang, Hong; Yin, Lei; Zhang, Jiwen; Fawcett, John Paul; Gu, Jingkai

    2017-11-01

    Porcine relaxin is a 6 kDa peptide hormone of pregnancy with important physiological and pharmacological effects. It contains a number of analogs of which porcine relaxin B29 is one of the most important. To support the development of porcine relaxin B29 as a new drug, we established an UPLC-MS/MS method for its quantitation in dog plasma. Sample preparation by protein precipitation and ion exchange solid phase extraction was followed by UPLC on an XBridge™ BEH300 C18 column at 40 °C in a run time of only 5.5 min. Detection was performed on a Qtrap 6500 mass spectrometer using ESI in the positive ion mode with MRM of the transitions at m/z 831.7 [M+7H] 7+  → 505.4 and m/z 1162.4 [M+5H] 5+  → 226 for pRLX B29 and internal standard (recombinant human insulin), respectively. The method was linear over the concentration range 30-2000 ng/mL with no matrix effects. Intra- and inter-day precisions were < 15% with accuracies in the range 98.8-100.6%. The method was successfully applied to a pharmacokinetic study in beagle dogs after administration of a 0.15 mg/kg intravenous dose. Graphical abstract Sample preparation and detection procedure.

  15. Solid-phase extraction of chlorophenols in seawater using a magnetic ionic liquid molecularly imprinted polymer with incorporated silicon dioxide as a sorbent.

    PubMed

    Ma, Wanwan; Row, Kyung Ho

    2018-07-20

    A type of magnetic ionic liquid based molecularly imprinted polymer coated on SiO 2 (Fe 3 O 4 @SiO 2 @IL-MIPs) was prepared with 1-vinyl-3-ethylimidazole ionic liquid as functional monomer, and 1,4-butane-3,3'-bis-1-ethylimidazole ionic liquid as cross linker, 4-Chlorophenol as template was successfully applied as a selective adsorbent for selective extraction of 5 chlorophenols in seawater samples by using the magnetic solid-phase extraction (MSPE) method. 11 types of Fe 3 O 4 @SiO 2 @IL-MIPs were synthesized and investigated for their different compositions of functional monomer (such as [C 2 min][Br], [C 2 min][BF 4 ], [C 2 min][PF 6 ], acrylamide, methacrylic acid and 4-vinyl pyridine) and cross-linker (such as [C 4 min 2 ][Br], [C 4 min 2 ][BF 4 ], [C 4 min 2 ][PF 6 ], divinylbenzene, and ethylene glycol dimethacrylate), respectively. The [C 2 min][BF 4 ] and [C 4 min 2 ][PF 6 ] based Fe 3 O 4 @SiO 2 @IL-MIP with the highest extraction efficiencies was applied to the optimization experiment of MSPE process (including extraction time, adsorbent mass and desorption solvents). Good linearity was obtained with correlation coefficients (R 2 ) over 0.9990 and the relative standard deviations for the intra-day and inter-day determination were less than 3.10% with the extraction recoveries ranged from 85.0% to 98.4%. The results indicated that the proposed Fe 3 O 4 @SiO 2 @IL-MIPs possesses great identification and adsorption properties, and could be used as a good sorbent for selective extraction of CPs in environment waters. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Distribution of phthalates, pesticides and drug residues in the dissolved, particulate and sedimentary phases from transboundary rivers (France-Belgium).

    PubMed

    Net, Sopheak; Rabodonirina, Suzanah; Sghaier, Rafika Ben; Dumoulin, David; Chbib, Chaza; Tlili, Ines; Ouddane, Baghdad

    2015-07-15

    Various drug residues, pesticides and phthalates are ubiquitous in the environment. Their presence in the environment has attracted considerable attention due to their potential impacts on ecosystem functioning and on public health. In this work, 14 drug residues, 24 pesticides and 6 phthalates have been quantified in three matrices (in the dissolved phase, associated to suspended solid matter (SSM), and in sediment) collected from fifteen watercourses and rivers located in a highly industrialized zone at the cross-border area of Northern France and Belgium. The extractions have been carried out using accelerated solvent extraction (ASE) for solid matrices (SSM and sediment) and using solid phase extraction (SPE) for liquid matrix. The final extract was analyzed using GC-MS technique. Among the three classes of compounds, phthalates have been found at highest level compared to pesticides and drug residues. The Σ6PAE concentrations were ranging from 17.2±2.58 to 179.1±26.9μgL(-1) in dissolved phase, from 2.9±0.4 to 21.1±3.2μgL(-1) in SSM and from 1.1±0.2 to 11.9±1.8μgg(-1)dw in sediment. The Σ14drug residue concentrations were lower than 1.3μgL(-1) in the dissolved phases, lower than 30ngL(-1) associated to SSM and from nondetectable levels to 60.7±9.1ngg(-1)dw in sediment. For pesticides, all compounds were below the LOQ values in dissolved phase and in sediment, and only EPTC could be quantified in SSM. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Radioactivity concentration in liquid and solid phases of scale and sludge generated in the petroleum industry.

    PubMed

    Paranhos Gazineu, Maria Helena; de Araújo, Andressa Arruda; Brandão, Yana Batista; Hazin, Clovis Abrahão; de O Godoy, José Marcos

    2005-01-01

    Scales and sludge generated during oil extraction and production can contain uranium, thorium, radium and other natural radionuclides, which can cause exposure of maintenance personnel. This work shows how the oil content can influence the results of measurements of radionuclide concentration in scale and sludge. Samples were taken from a PETROBRAS unit in Northeast Brazil. They were collected directly from the inner surface of water pipes or from barrels stored in the waste storage area of the E&P unit. The oil was separated from the solids with a Soxhlet extractor by using aguarras at 90+/-5 degrees C as solvent. Concentrations of 226Ra and 228Ra in the samples were determined before and after oil extraction by using an HPGe gamma spectrometric system. The results showed an increase in the radionuclide concentration in the solid (dry) phase, indicating that the above radionuclides concentrate mostly in the solid material.

  18. Vortex assisted solid-phase extraction of lead(II) using orthorhombic nanosized Bi2WO6 as a sorbent.

    PubMed

    Baghban, Neda; Yilmaz, Erkan; Soylak, Mustafa

    2017-12-07

    Nanosized single crystal orthorhombic Bi 2 WO 6 was synthesized by a hydrothermal method and used as a sorbent for vortex assisted solid phase extraction of lead(II). The crystal and molecular structure of the sorbent was examined using XRD, Raman, SEM and SEM-EDX analysis. Various parameters affecting extraction efficiency were optimized by using multivariate design. The effect of diverse ions on the extraction also was studied. Lead was quantified by flame atomic absorption spectrometry (FAAS). The recoveries of lead(II) from spiked samples (at a typical spiking level of 200-400 ng·mL -1 ) are >95%. Other figures of merit includes (a) a detection limit of 6 ng·mL -1 , (b) a preconcentration factor of 50, (c) a relative standard deviation of 1.6%, and (d) and adsorption capacity of 6.6 mg·g -1 . The procedure was successfully applied to accurate determination of lead in (spiked) pomegranate and water samples. Graphical abstract Nanosized single crystal orthorhombic Bi 2 WO 6 was synthesized and characterized by a hydrothermal method and used as a sorbent for vortex assisted solid phase extraction of lead(II). The procedure was successfully applied to accurate determination of lead in (spiked) pomegranate and water samples.

  19. Development of supercritical carbon dioxide extraction with a solid phase trap for dioxins in soils and sediments.

    PubMed

    Miyawaki, Takashi; Kawashima, Ayato; Honda, Katsuhisa

    2008-01-01

    A method involving supercritical fluid extraction (SFE) with a solid phase trap containing activated alumina was investigated for the rapid analysis of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and dioxin like polychlorinated biphenyls (DL-PCBs) in soils and sediments. The samples were extracted by using supercritical carbon dioxide with water (2% versus CO(2) flow velocity) being used as an entrainer at a pressure of 30 MPa and a temperature of 130 degrees C for 50 min. The extracts were adsorbed on an activated alumina trap that was maintained at a temperature of 150 degrees C, and then, PCDD/DFs and DL-PCBs were eluted with 20 ml of hexane at 60 degrees C. After concentration, they were measured with a high-resolution gas chromatograph interfaced to a high-resolution mass spectrometric detector. The average concentrations of PCDD/DFs and DL-PCBs corresponded to the results obtained by the conventional method, and the reproducibility of this SFE method was below 21% of the relative standard deviations for all samples. The total time required for the analysis of the pretreatment of this method was only 2 h.

  20. High-throughput determination of faropenem in human plasma and urine by on-line solid-phase extraction coupled to high-performance liquid chromatography with UV detection and its application to the pharmacokinetic study.

    PubMed

    Xie, Rui; Wen, Jun; Wei, Hua; Fan, Guorong; Zhang, Dabing

    2010-05-01

    An automated system using on-line solid-phase extraction and HPLC with UV detection was developed for the determination of faropenem in human plasma and urine. Analytical process was performed isocratically with two reversed-phase columns connected by a switching valve. After simple pretreatment for plasma and urine with acetonitrile, a volume of 100microl upper layer of the plasma or urine samples was injected for on-line SPE column switching HPLC-UV analysis. The analytes were retained on the self-made trap column (Lichrospher C(18), 4.6mmx37mm, 25microm) with the loading solvent (20mM NaH(2)PO(4) adjusted pH 3.5) at flow rate of 2mlmin(-1), and most matrix materials were removed from the column to waste. After 0.5min washing, the valve was switched to another position so that the target analytes could be eluted from trap column to analytical column in the back-flush mode by the mobile phase (acetonitrile-20mM NaH(2)PO(4) adjusted pH 3.5, 16:84, v/v) at flow rate of 1.5mlmin(-1), and then separated on the analytical column (Ultimate XB-C(18), 4.6mmx50mm, 5microm).The complete cycle of the on-line SPE preconcentration purification and HPLC separation of the analytes was 5min. Calibration curves with good linearities (r=0.9994 for plasma sample and r=0.9988 for urine sample) were obtained in the range 0.02-5microgml(-1) in plasma and 0.05-10microg ml(-1) in urine for faropenem. The optimized method showed good performance in terms of specificity, linearity, detection and quantification limits, precision and accuracy. The method was successfully utilized to quantify faropenem in human plasma and urine to support the clinical pharmacokinetic studies. Copyright 2009 Elsevier B.V. All rights reserved.

  1. Critical assessment of three high performance liquid chromatography analytical methods for food carotenoid quantification.

    PubMed

    Dias, M Graça; Oliveira, Luísa; Camões, M Filomena G F C; Nunes, Baltazar; Versloot, Pieter; Hulshof, Paul J M

    2010-05-21

    Three sets of extraction/saponification/HPLC conditions for food carotenoid quantification were technically and economically compared. Samples were analysed for carotenoids alpha-carotene, beta-carotene, beta-cryptoxanthin, lutein, lycopene, and zeaxanthin. All methods demonstrated good performance in the analysis of a composite food standard reference material for the analytes they are applicable to. Methods using two serial connected C(18) columns and a mobile phase based on acetonitrile, achieved a better carotenoid separation than the method using a mobile phase based on methanol and one C(18)-column. Carotenoids from leafy green vegetable matrices appeared to be better extracted with a mixture of methanol and tetrahydrofuran than with tetrahydrofuran alone. Costs of carotenoid determination in foods were lower for the method with mobile phase based on methanol. However for some food matrices and in the case of E-Z isomer separations, this was not technically satisfactory. Food extraction with methanol and tetrahydrofuran with direct evaporation of these solvents, and saponification (when needed) using pyrogallol as antioxidant, combined with a HPLC system using a slight gradient mobile phase based on acetonitrile and a stationary phase composed by two serial connected C(18) columns was the most technically and economically favourable method. 2010. Published by Elsevier B.V.

  2. Determination of triazine herbicides in seaweeds: development of a sample preparation method based on Matrix Solid Phase Dispersion and Solid Phase Extraction Clean-up.

    PubMed

    Rodríguez-González, N; González-Castro, M J; Beceiro-González, E; Muniategui-Lorenzo, S; Prada-Rodríguez, D

    2014-04-01

    A method using dual process columns of Matrix Solid Phase Dispersion (MSPD) and Solid Phase Extraction (SPE) has been developed for extracting and cleaning-up of nine triazine herbicides (ametryn, atrazine, cyanazine, prometryn, propazine, simazine, simetryn, terbuthylazine and terbutryn) in seaweed samples. Under optimized conditions, samples were blended with 2g of octasilyl-derivatized silica (C8) and transferred into an SPE cartridge containing ENVI-Carb II/PSA (0.5/0.5 g) as a clean up co-sorbent. Then the dispersed sample was washed with 10 mL of n-hexane and triazines were eluted with 20 mL ethyl acetate and 5 mL acetonitrile. Finally the extract was concentrated to dryness, re-constituted with 1 mL methanol:water (1:1) and injected into the HPLC-DAD system. The linearity of the calibration curves was excellent in matrix matched standards, and yielded the coefficients of determination>0.995 for all the target analytes. The recoveries ranged from 75% to 100% with relative standard deviations lower than 7%. The achieved LOQs (<10 µg kg(-1)) for all triazines under study permits to ensure proper determination at the maximum allowed residue levels set in the European Union Legislation. Samples of three seaweeds were subjected to the procedure proving the suitability of MSPD method for the analysis of triazines in different seaweeds samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. New environmentally friendly MSPD solid support based on golden mussel shell: characterization and application for extraction of organic contaminants from mussel tissue.

    PubMed

    Rombaldi, Caroline; de Oliveira Arias, Jean Lucas; Hertzog, Gabriel Ianzer; Caldas, Sergiane Souza; Vieira, João P; Primel, Ednei Gilberto

    2015-06-01

    The use of golden mussel shells as a solid support in vortex-assisted matrix solid-phase dispersion (MSPD) was evaluated for the first time for extraction of residues of 11 pesticides and nine pharmaceutical and personal care products from mussel tissue samples. After they had been washed, dried, and milled, the mussel shells were characterized by scanning electron microscopy, energy-dispersive X-ray spectroscopy, infrared spectroscopy, and Brunauer-Emmett-Teller analysis. The MSPD procedure with analysis by liquid chromatography-tandem mass spectrometry allowed the determination of target analytes at trace concentrations (nanograms per gram), with mean recoveries ranging from 61 to 107 % and relative standard deviations lower than 18 %. The optimized method consisted of dispersion of 0.5 g of mussel tissue, 0.5 g of NaSO4, and 0.5 g of golden mussel shell for 5 min, and subsequent extraction with 5 mL of ethyl acetate. The matrix effect was evaluated, and a low effect was found for all compounds. The results showed that mussel shell is an effective material and a less expensive material than materials that have traditionally been used, i.e., it may be used in the MSPD dispersion step during the extraction of pesticides and pharmaceutical and personal care products from golden mussel tissues. Graphical Abstract Vortex-assited matrix solid-phase dispersion for extraction of 11 pesticides and 9 PPCPs care products from mussel tissue samples.

  4. Application of solid-phase microextraction method to determine bioavailable fraction of PAH in hazardous waste.

    PubMed

    Jefimova, J; Irha, N; Mägi, R; Kirso, U

    2012-10-01

    The solid-phase microextraction (SPME) method was developed to determine PAH free dissolved concentration (C(free)) in field leachates from hazardous waste disposal. SPME technique, involving a 100-μm polydimethylsiloxane (PDMS) fiber coupled to GC-MS was optimized for determination of C(free). The following PAH were found in bioavailable form: acenaphthylene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, with C(free) varying between 2.38 and 62.35 ng/L. Conventional solvent extraction was used for measurement of total concentration (C(total)) in the same samples, and ranging from 1.26 to 77.56 μg/L. Determining C(free) of the hydrophobic toxic pollutants could give useful information for risk assessment of the hazardous waste.

  5. Quantification of 31 illicit and medicinal drugs and metabolites in whole blood by fully automated solid-phase extraction and ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Bjørk, Marie Kjærgaard; Simonsen, Kirsten Wiese; Andersen, David Wederkinck; Dalsgaard, Petur Weihe; Sigurðardóttir, Stella Rögn; Linnet, Kristian; Rasmussen, Brian Schou

    2013-03-01

    An efficient method for analyzing illegal and medicinal drugs in whole blood using fully automated sample preparation and short ultra-high-performance liquid chromatography-tandem mass spectrometry (MS/MS) run time is presented. A selection of 31 drugs, including amphetamines, cocaine, opioids, and benzodiazepines, was used. In order to increase the efficiency of routine analysis, a robotic system based on automated liquid handling and capable of handling all unit operation for sample preparation was built on a Freedom Evo 200 platform with several add-ons from Tecan and third-party vendors. Solid-phase extraction was performed using Strata X-C plates. Extraction time for 96 samples was less than 3 h. Chromatography was performed using an ACQUITY UPLC system (Waters Corporation, Milford, USA). Analytes were separated on a 100 mm × 2.1 mm, 1.7 μm Acquity UPLC CSH C(18) column using a 6.5 min 0.1 % ammonia (25 %) in water/0.1 % ammonia (25 %) in methanol gradient and quantified by MS/MS (Waters Quattro Premier XE) in multiple-reaction monitoring mode. Full validation, including linearity, precision and trueness, matrix effect, ion suppression/enhancement of co-eluting analytes, recovery, and specificity, was performed. The method was employed successfully in the laboratory and used for routine analysis of forensic material. In combination with tetrahydrocannabinol analysis, the method covered 96 % of cases involving driving under the influence of drugs. The manual labor involved in preparing blood samples, solvents, etc., was reduced to a half an hour per batch. The automated sample preparation setup also minimized human exposure to hazardous materials, provided highly improved ergonomics, and eliminated manual pipetting.

  6. Multiresidue determination of chlorophenoxy acid herbicides in human urine samples by use of solid-phase extraction and capillary LC-UV detection.

    PubMed

    Rosales-Conrado, N; León-González, M E; Pérez-Arribas, L V; Polo-Díez, L M

    2008-01-01

    Chlorophenoxy acid herbicides are intensively applied to get rid of unwanted plants because of their low cost and selectivity. Due to their toxicity, which depends on their chemical form, the European Community has established legal directives to restrict their use and to control their maximum residue levels in several matrices. Determination of chlorophenoxy acids-2,4-dichlorophenoxyacetic acid (2,4-D), 4-chloro-2-methylphenoxyacetic acid (MCPA), 2-(2,4-dichlorophenoxy)propanoic acid (2,4-DP), 2-(4-chloro-2-methylphenoxy)propanoic acid (MCPP), 4-(4-chloro-2-methylphenoxy)butanoic acid (MCPB) and 2-(2,4,5-trichlorophenoxy)propanoic acid (2,4,5-TP) in spiked human urine samples has been carried out by capillary LC, after solid-phase extraction on a column packed with silica C18 restricted-access material. Chromatographic analysis was performed in gradient-elution mode at 25 degrees C, with injection of 20 microL low-organic-solvent composition herbicide solutions for focusing purposes on the head of the capillary column, and diode array detection at 232 nm. Urine samples collected during 24 h from healthy and unexposed volunteers were spiked in the concentration range 25-150 microg L(-1); recoveries obtained were between 66 and 100% (n = 6 for each spiked level) and RSDs (relative standard deviations) were between 1 and 5%. Detection limits in the urine samples from volunteers were between 3.5 and 6.0 microg L(-1). The developed methodology has allowed the clean-up and preconcentration of low volumes of untreated human urine without previous treatment, showing the effectiveness of the employed SPE sorbent for extracting the target analytes and ultimately resulting in the reduction of the sample-preparation time.

  7. Use of different sample temperatures in a single extraction procedure for the screening of the aroma profile of plant matrices by headspace solid-phase microextraction.

    PubMed

    Martendal, Edmar; de Souza Silveira, Cristine Durante; Nardini, Giuliana Stael; Carasek, Eduardo

    2011-06-17

    This study proposes a new approach to the optimization of the extraction of the volatile fraction of plant matrices using the headspace solid-phase microextraction (HS-SPME) technique. The optimization focused on the extraction time and temperature using a CAR/DVB/PDMS 50/30 μm SPME fiber and 100mg of a mixture of plants as the sample in a 15-mL vial. The extraction time (10-60 min) and temperature (5-60 °C) were optimized by means of a central composite design. The chromatogram was divided into four groups of peaks based on the elution temperature to provide a better understanding of the influence of the extraction parameters on the extraction efficiency considering compounds with different volatilities/polarities. In view of the different optimum extraction time and temperature conditions obtained for each group, a new approach based on the use of two extraction temperatures in the same procedure is proposed. The optimum conditions were achieved by extracting for 30 min with a sample temperature of 60 °C followed by a further 15 min at 5 °C. The proposed method was compared with the optimized conventional method based on a single extraction temperature (45 min of extraction at 50 °C) by submitting five samples to both procedures. The proposed method led to better results in all cases, considering as the response both peak area and the number of identified peaks. The newly proposed optimization approach provided an excellent alternative procedure to extract analytes with quite different volatilities in the same procedure. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harris, J.M.

    Chemical phenomena occurring at boundaries between insulating solids and liquids (adsorption, partition, monolayer self-assembly, catalysis, and chemical reactions) are important to energy-related analytical chemistry. These phenomena are central to chromatography, solid-phase extraction, immobilized analytical reagents, and optical sensors. Chemical interactions in these processes cannot generally be identified solely by equilibrium surface concentrations, since the steady-state behavior does not reveal the mechanism or rates of surface reactions. Goal therefore is to develop surface-sensitive spectroscopies by which chemical kinetics at liquid/solid interfaces can be observed on time-scales from nanoseconds to seconds. In the first year, we have used Joule-discharge heating kinetics tomore » study pore structure of silica gels; effects of pore diameter, particle size, and chemical modification on pore connectivity were investigated. Temperature-jump relaxation measurements of sorption/desorption kinetics at liquid/solid interfaces were also carried out using Joule heating; kinetic barriers to sorption of ions from solution were found for both C18 and Cl surfaces. Through a collaboration with Fritz-Haber Institute in Berlin, we were able to acquire laser temperature-jump data on kinetics at liquid/solid interfaces using a colloidal sample. We also quantified the rate of migration of covalently attached ligands on silica surfaces; from the temperature dependence, the large energy barrier to migration was estimated. A review of applications of electronic spectroscopy (absorption and fluorescence) to reversed-phase chromatographic interfaces was published.« less

  9. Solvent extraction of Li+, H3O+ and NH4+ into nitrobenzene by using sodium dicarbollylcobaltate and calix[4]arene-bis(t-octylbenzo-18-crown-6)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Makrlik, Emanuel; Selucky, P.; Vanura, Petr

    2013-01-01

    From extraction experiments and c-activity measurements, the exchange extraction constants corresponding to the general equilibrium M+ (aq) + NaL+ (nb) , ML+ (nb) + Na+ (aq) taking place in the two-phase water nitrobenzene system (M+ = Li+, H3O+, NH+4; L = calix[4]arene-bis(t-octylbenzo-18-crown-6); aq = aqueous phase, nb = nitrobenzene phase) were evaluated. Furthermore, the stability constants of the ML+ complexes in nitrobenzene saturated with water were calculated; they were found to increase in the following cation order: zH3O+ < Li+ < NH+4.

  10. A sensitive microextraction by packed sorbent-based methodology combined with ultra-high pressure liquid chromatography as a powerful technique for analysis of biologically active flavonols in wines.

    PubMed

    Silva, Catarina L; Gonçalves, João L; Câmara, José S

    2012-08-20

    A new approach based on microextraction by packed sorbent (MEPS) and reversed-phase high-throughput ultra high pressure liquid chromatography (UHPLC) method that uses a gradient elution and diode array detection to quantitate three biologically active flavonols in wines, myricetin, quercetin, and kaempferol, is described. In addition to performing routine experiments to establish the validity of the assay to internationally accepted criteria (selectivity, linearity, sensitivity, precision, accuracy), experiments are included to assess the effect of the important experimental parameters such as the type of sorbent material (C2, C8, C18, SIL, and C8/SCX), number of extraction cycles (extract-discard), elution volume, sample volume, and ethanol content, on the MEPS performance. The optimal conditions of MEPS extraction were obtained using C8 sorbent and small sample volumes (250μL) in five extraction cycle and in a short time period (about 5min for the entire sample preparation step). Under optimized conditions, excellent linearity (R(values)(2)>0.9963), limits of detection of 0.006μgmL(-1) (quercetin) to 0.013μgmL(-1) (myricetin) and precision within 0.5-3.1% were observed for the target flavonols. The average recoveries of myricetin, quercetin and kaempferol for real samples were 83.0-97.7% with relative standard deviation (RSD, %) lower than 1.6%. The results obtained showed that the most abundant flavonol in the analyzed samples was myricetin (5.8±3.7μgmL(-1)). Quercetin (0.97±0.41μgmL(-1)) and kaempferol (0.66±0.24μgmL(-1)) were found in a lower concentration. The optimized MEPS(C8) method was compared with a reverse-phase solid-phase extraction (SPE) procedure using as sorbent a macroporous copolymer made from a balanced ratio of two monomers, the lipophilic divinylbenzene and the hydrophilic N-vinylpyrrolidone (Oasis HLB) were used as reference. MEPS(C8) approach offers an attractive alternative for analysis of flavonols in wines, providing a number of advantages including highest extraction efficiency (from 85.9±0.9% to 92.1±0.5%) in the shortest extraction time with low solvent consumption, fast sample throughput, more environmentally friendly and easy to perform. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples

    PubMed Central

    Chen, Ping-Hung; Chen, Shun-Niang; Tseng, Sheng-Hao; Deng, Ming-Jay; Lin, Yang-Wei; Sun, Yuh-Chang

    2016-01-01

    This paper describes a fabrication protocol for a dipole-assisted solid phase extraction (SPE) microchip available for trace metal analysis in water samples. A brief overview of the evolution of chip-based SPE techniques is provided. This is followed by an introduction to specific polymeric materials and their role in SPE. To develop an innovative dipole-assisted SPE technique, a chlorine (Cl)-containing SPE functionality was implanted into a poly(methyl methacrylate) (PMMA) microchip. Herein, diverse analytical techniques including contact angle analysis, Raman spectroscopic analysis, and laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) analysis were employed to validate the utility of the implantation protocol of the C-Cl moieties on the PMMA. The analytical results of the X-ray absorption near-edge structure (XANES) analysis also demonstrated the feasibility of the Cl-containing PMMA used as an extraction medium by virtue of the dipole-ion interactions between the highly electronegative C-Cl moieties and the positively charged metal ions. PMID:27584954

  12. Application of solid phase extraction on multiwalled carbon nanotubes of some heavy metal ions to analysis of skin whitening cosmetics using ICP-AES.

    PubMed

    Alqadami, Ayoub A; Abdalla, Mohammad Abulhassan; AlOthman, Zeid A; Omer, Kamal

    2013-01-14

    A novel and highly sensitive method for the determination of some heavy metals in skin whitening cosmetics creams using multiwalled carbon nanotubes MWCNTs as solid phase extraction sorbent for the preconcentration of these heavy metals prior to their determination by inductively coupled plasma atomic emission spectrometry is described. Different practical parameters have been thoroughly investigated and the optimum experimental conditions were employed. The developed method was then applied for the determination of arsenic, bismuth, cadmium, mercury, lead and titanium in samples of skin whitening cosmetics. The detection limits under these conditions for As, Bi, Cd, Pb, Hg and Ti were 2.4, 4.08, 0.3, 2.1, 1.8, and 1.8 ng·mL-1, respectively. The relative standard deviations (RSDs) were found to be less than 2.0%. For validation, a certified reference material of NIST SRM 1570a spinach leaves was analyzed and the determined values were in good agreement with the certified values. The recoveries for spiked samples were found to be in the range of 89.6-104.4%.

  13. A multiresidue method for the analysis of 90 pesticides, 16 PAHs, and 22 PCBs in honey using QuEChERS-SPME.

    PubMed

    Al-Alam, Josephine; Fajloun, Ziad; Chbani, Asma; Millet, Maurice

    2017-08-01

    An optimized analytical method was developed for the simultaneous analysis of 90 pesticides, 16 polycyclic aromatic hydrocarbons, and 22 polychlorinated biphenyls. The method was based on quick, easy, cheap, effective, rugged, and safe (QuEChERS) extraction using acetonitrile followed by a dispersive solid-phase extraction cleanup using primary-secondary amine and octadecyl (C 18 ). The extract obtained was concentrated by evaporation and then reconstituted with acetonitrile to prepare it for chromatographic analysis by liquid chromatography-triple-quadrupole tandem mass spectrometry and gas chromatography-ion-trap tandem mass spectrometry, which was preceded by a preconcentration step using solid-phase microextraction with appropriate fibers. The combination of the two extraction steps ensured efficient extract cleanup. The use of the two analytical instruments allowed the analysis of a large number of pollutants with a high reliability rate. The method developed was validated for linearity, which was studied with use of matrix-matched calibration curves in the concentration range between 10 and 3000 ng g -1 . The correlation coefficient (R 2 ) obtained was higher than 0.98 for most of the target compounds, with a relative standard deviation lower than 20% for repeatability and reproducibility. The limits of detection and quantification were lower than 20 and 60 ng g -1 respectively for the compounds analyzed, and the recoveries were between 60% and 103% for most compounds. Finally, the method was tested for its efficiency on real samples by the analysis of three honey samples in which seven pesticides and nine polycyclic aromatic hydrocarbons were determined. Graphical Abstract ᅟ.

  14. Fuel spill identification using solid-phase extraction and solid-phase microextraction. 1. Aviation turbine fuels.

    PubMed

    Lavine, B K; Brzozowski, D M; Ritter, J; Moores, A J; Mayfield, H T

    2001-12-01

    The water-soluble fraction of aviation jet fuels is examined using solid-phase extraction and solid-phase microextraction. Gas chromatographic profiles of solid-phase extracts and solid-phase microextracts of the water-soluble fraction of kerosene- and nonkerosene-based jet fuels reveal that each jet fuel possesses a unique profile. Pattern recognition analysis reveals fingerprint patterns within the data characteristic of fuel type. By using a novel genetic algorithm (GA) that emulates human pattern recognition through machine learning, it is possible to identify features characteristic of the chromatographic profile of each fuel class. The pattern recognition GA identifies a set of features that optimize the separation of the fuel classes in a plot of the two largest principal components of the data. Because principal components maximize variance, the bulk of the information encoded by the selected features is primarily about the differences between the fuel classes.

  15. Quantitation of promethazine and metabolites in urine samples using on-line solid-phase extraction and column-switching

    NASA Technical Reports Server (NTRS)

    Song, Q.; Putcha, L.; Harm, D. L. (Principal Investigator)

    2001-01-01

    A chromatographic method for the quantitation of promethazine (PMZ) and its three metabolites in urine employing on-line solid-phase extraction and column-switching has been developed. The column-switching system described here uses an extraction column for the purification of PMZ and its metabolites from a urine matrix. The extraneous matrix interference was removed by flushing the extraction column with a gradient elution. The analytes of interest were then eluted onto an analytical column for further chromatographic separation using a mobile phase of greater solvent strength. This method is specific and sensitive with a range of 3.75-1400 ng/ml for PMZ and 2.5-1400 ng/ml for the metabolites promethazine sulfoxide, monodesmethyl promethazine sulfoxide and monodesmethyl promethazine. The lower limits of quantitation (LLOQ) were 3.75 ng/ml with less than 6.2% C.V. for PMZ and 2.50 ng/ml with less than 11.5% C.V. for metabolites based on a signal-to-noise ratio of 10:1 or greater. The accuracy and precision were within +/- 11.8% in bias and not greater than 5.5% C.V. in intra- and inter-assay precision for PMZ and metabolites. Method robustness was investigated using a Plackett-Burman experimental design. The applicability of the analytical method for pharmacokinetic studies in humans is illustrated.

  16. Development and validation of a solid-phase extraction method coupled to liquid chromatography with fluorescence detection for the determination of fluoroquinolone residues in powdered infant formulae. Application to the analysis of samples from the Spanish and Latin American market.

    PubMed

    Rodriguez, E; Moreno-Bondi, M C; Marazuela, M D

    2008-10-31

    This paper describes a new method for the effective extraction, clean-up and chromatographic analysis of residues of four fluoroquinolones (ciprofloxacin, enrofloxacin, danofloxacin and sarafloxacin) in powdered infant formulae and follow-on preparations. Samples were reconstituted following the manufacturer's recommendations and treated with trichloroacetic acid in methanol 10% (w/v) for deproteinization. Two solid-phase extraction cartridges have been evaluated for sample clean-up and preconcentration, Strata Screen A and Strata X and the later provided the best recoveries for all the analytes tested. Chromatographic analysis has been carried out using a polar endcapped column (AQUA C(18)) and fluorescence detection, with lomefloxacin (LOME) as internal standard. Method validation has been performed according to European Commission Decision 2002/657/EC criteria, in terms of linearity, recovery, precision, specificity, decision limit (CC(alpha)) and detection capability (CC(beta)). Typical recoveries ranged between 70 and 110% at levels below and above the maximum residue limits of the target analytes in bovine milk, with an excellent intralab reproducibility (RSDs<7%). Matrix effects did not significantly affect method accuracy, as evidenced by analyzing different brands of milk. The method has been successfully applied to the analysis of 100 samples of infant and follow-on formulae of the Spanish and Latin American market, using LC-MS/MS as confirmatory technique.

  17. [Determination of triclosan and triclocarban in human breast milk by solid-phase extraction and ultra performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Zhang, Pin; Zhang, Jing; Shi, Ying; Shao, Bing

    2015-03-01

    An analytical method was developed to simultaneously detect triclosan (TCS) and triclocarban (TCC) in human breast milk using solid-phase extraction (SPE) with ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). Samples were extracted by acetonitrile and purified with C -18 SPE cartridge after enzymolysis with β-glucuronidase/arylsulfatase. The chromatographic separation was performed on a Waters ACQUITY UPLC™ HSS T3 column (100 mm x 2. 1 mm, 1. 8 µm) with gradient elution using methanol and water at a flow rate of 0. 3 ml/min. The target analytes were assayed by triple quadrupole mass spectrometer operating in the negative ion mode. Quantification was performed by isotopic internal standard calibration. Satisfactory linearity (r2 > 0. 999) was obtained over the range of 0. 2 - 20. 0 µg/L and 0. 02 - 2. 0 µg/L for triclosan and triclocarban, respectively, with the limits of quantifications (LOQs) of 0. 41 and 0. 03 µg/kg. Average recoveries of two target compounds (spiked at three concentration levels) ranged from 100. 2% to 119. 3%, with the relative standard deviations (RSDs) between 5. 91% and 11. 31% (n =6). Twenty-five real samples (n = 25) were detected containing TCS and TCC at concentrations of < LOQ - 0. 77 µg/kg and < LOQ - 4. 28 µg/kg, respectively. Due to its high sensitivity and good reproductivity, this method can be applied to analyze TCS and TCC in human breast milk.

  18. Selective and rapid determination of tadalafil and finasteride using solid phase extraction by high performance liquid chromatography and tandem mass spectrometry.

    PubMed

    Pappula, Nagaraju; Kodali, Balaji; Datla, Peda Varma

    2018-04-15

    Highly selective and fast liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed and validated for simultaneous determination of tadalafil (TDL) and finasteride (FNS) in human plasma. The method was successfully applied for analysis of TDL and FNS samples in clinical study. The method was validated as per USFDA (United States Food and Drug Administration), EMA (European Medicines Agency), and ANVISA (Agência Nacional de Vigilância Sanitária-Brazil) bio analytical method validation guidelines. Glyburide (GLB) was used as common internal standard (ISTD) for both analytes. The selected multiple reaction monitoring (MRM) transitions for mass spectrometric analysis were m/z 390.2/268.2, m/z 373.3/305.4 and m/z 494.2/369.1 for TDL, FNS and ISTD respectively. The extraction of analytes and ISTD was accomplished by a simple solid phase extraction (SPE) procedure. Rapid analysis time was achieved on Zorbax Eclipse C18 column (50 × 4.6 mm, 5 μm). The calibration ranges for TDL and FNS were 5-800 ng/ml and 0.2-30 ng/ml respectively. The results of precision and accuracy, linearity, recovery and matrix effect of the method are acceptable. The accuracy was in the range of 92.9%-106.4% and method precision was also good; %CV was less than 8.1%. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Ionic liquid molecularly imprinted polymers for application in pipette-tip solid-phase extraction coupled with gas chromatography for rapid screening of dicofol in celery.

    PubMed

    Yan, Hongyuan; Yang, Chen; Sun, Yunyun; Row, Kyung Ho

    2014-09-26

    A new type of ionic liquid molecularly imprinted polymers (IL-MIPs) synthesized by precipitation polymerization using 1-allyl-3-methylimidazolium bromide as an auxiliary solvent and α-chloro-dichlorodiphenyltrichloroethane (α-chloro-DDT) as the template was applied as a selective sorbent of minimized pipette tip-solid-phase extraction (PT-SPE) for rapid isolation and extraction of dicofol (DCF) from celery samples. The pretreatment procedure of celery samples involved only 2.0mg of IL-MIPs, 0.8 mL of acetonitrile-water (ACN-H2O; 1:1, v/v) (washing solvent), and 1.0 mL of acetone-10% acetic acid (HOAc) (elution solvent). Compared with molecularly imprinted polymers (MIPs), ionic liquid-non-imprinted polymers (IL-NIPs) and conventional sorbents such as C18, Si, NH2, and Al2O3-N, IL-MIPs showed higher adsorption and purification capacity to DCF in aqueous solution. Good linearity for DCF was observed in the range from 2.3 to 232.5 ng g(-1) (r(2)=0.9995). The average recoveries at three spiking levels ranged from 86.6% to 101.9% with relative standard deviations (RSDs) of ≤ 6.5% (n=3). The presented IL-MIPs-PT-SPE-GC/ECD method combines the advantages of MIPs, IL, and PT-SPE, and can be used in aqueous conditions with high affinity and selectivity to analytes of complex samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Determination of phthalates released from paper packaging materials by solid-phase extraction-high-performance liquid chromatography.

    PubMed

    Gao, Xin; Yang, Bofeng; Tang, Zhixu; Luo, Xin; Wang, Fengmei; Xu, Hui; Cai, Xue

    2014-01-01

    A solid phase extraction (SPE) high-performance liquid chromatography (HPLC) method was developed for the simultaneous determination of 10 phthalic acid esters (dimethyl phthalate, diethyl phthalate, dipropyl phthalate, benzylbutyl phthalate, diisobutyl phthalate, dicyclohexyl phthalate, diamyl phthalate, di-n-hexyl phthalate, di-n-octyl phthalate and di-2-ethylhexyl phthalate) released from food paper packaging materials. The use of distilled water, 3% acetic acid (w/v), 10% ethanol (v/v) and 95% ethanol (v/v) instead of the different types of food simulated the migration of 10 phthalic acid esters from food paper packaging materials; the phthalic acid esters in four food simulants were enriched and purified by a C18 SPE column and nitrogen blowing, and quantified by HPLC with a diode array detector. The chromatographic conditions and extraction conditions were optimized and all 10 of the phthalate acid esters had a maximum absorbance at 224 nm. The method showed limitations of detection in the range of 6.0-23.8 ng/mL the correlation coefficients were greater than 0.9999 in all cases, recovery values ranged between 71.27 and 106.97% at spiking levels of 30, 60 and 90 ng/mL and relative standard deviation values ranged from 0.86 to 8.00%. The method was considered to be simple, fast and reliable for a study on the migration of these 10 phthalic acid esters from food paper packaging materials into food.

  1. Graphene oxide-based composite monolith as new sorbent for the on-line solid phase extraction and high performance liquid chromatography determination of ß-sitosterol in food samples.

    PubMed

    Cui, Beijiao; Guo, Bin; Wang, Huimin; Zhang, Doudou; Liu, Haiyan; Bai, Ligai; Yan, Hongyuan; Han, Dandan

    2018-08-15

    A composite monolithic column was prepared by redox initiation method for the on-line purification and enrichment of β-sitosterol, in which graphene oxide (GO) was embedded. The obtained monolithic column was characterized by scanning electron microscopy (SEM) and nitrogen adsorption-desorption isotherm measurement, which indicated that the monolith possessed characteristics of porous structure and high permeability. Under the optimum conditions for extraction and determination, the calibration equation was y = 47.92 × -0.1391; the linear range was 0.008-1.0 mg mL -1 ; the linear regression coefficient was 0.998; the limit of detection (LOD) is 2.4 μg mL -1 ; the limit of quantitation (LOQ) was 8 μg mL -1 ; precisions for intra-day and inter-day assays presented as relative standard deviations were less than 4.3% and 6.8%, respectively. Under the selective conditions, the enrichment factor of the method was 119. The recovery was in the range of 80.40-98.00%. Moreover, the adsorption amount of the monolith was compared with silica gel-C18 adsorbent and the monolith without graphene oxide being embedded. The polymerization monolithic column showed high selectivity and good permeability, and it was successfully used as on-line solid-phase extraction (SPE) column for determination of β-sitosterol in edible oil. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Determination of limonin in grapefruit juice and other citrus juices by high-performance liquid chromatography.

    PubMed

    Van Beek, T A; Blaakmeer, A

    1989-03-03

    A method has been developed for the quantitation of the bitter component limonin in grapefruit juice and other citrus juices. The sample clean-up consisted of centrifugation, filtration and a selective, rapid and reproducible purification with a C2 solid-phase extraction column. The limonin concentration was determined by high-performance liquid chromatography on a C18 column with UV detection at 210 nm. A linear response was obtained from 0.0 to 45 ppm limonin. The minimum detectable amount was 2 ng. The minimum concentration which was detected without concentration with good precision was 0.1 ppm. The method was also used for the determination of limonin in different types of oranges, including navel oranges, mandarins, lemons, limes, pomelos and uglis.

  3. Analysis of perfluorinated carboxylic acids in soils II: optimization of chromatography and extraction.

    PubMed

    Washington, John W; Henderson, W Matthew; Ellington, J Jackson; Jenkins, Thomas M; Evans, John J

    2008-02-15

    With the objective of detecting and quantitating low concentrations of perfluorinated carboxylic acids (PFCAs), including perfluorooctanoic acid (PFOA), in soils, we compared the analytical suitability of liquid chromatography columns containing three different stationary phases, two different liquid chromatography-tandem mass spectrometry (LC/MS/MS) systems, and eight combinations of sample-extract pretreatments, extractions and cleanups on three test soils. For the columns and systems we tested, we achieved the greatest analytical sensitivity for PFCAs using a column with a C(18) stationary phase in a Waters LC/MS/MS. In this system we achieved an instrument detection limit for PFOA of 270 ag/microL, equating to about 14 fg of PFOA on-column. While an elementary acetonitrile/water extraction of soils recovers PFCAs effectively, natural soil organic matter also dissolved in the extracts commonly imparts significant noise that appears as broad, multi-nodal, asymmetric peaks that coelute with several PFCAs. The intensity and elution profile of this noise is highly variable among soils and it challenges detection of low concentrations of PFCAs by decreasing the signal-to-noise contrast. In an effort to decrease this background noise, we investigated several methods of pretreatment, extraction and cleanup, in a variety of combinations, that used alkaline and unbuffered water, acetonitrile, tetrabutylammonium hydrogen sulfate, methyl-tert-butyl ether, dispersed activated carbon and solid-phase extraction. For the combined objectives of complete recovery and minimization of background noise, we have chosen: (1) alkaline pretreatment; (2) extraction with acetonitrile/water; (3) evaporation to dryness; (4) reconstitution with tetrabutylammonium-hydrogen-sulfate ion-pairing solution; (5) ion-pair extraction to methyl-tert-butyl ether; (6) evaporation to dryness; (7) reconstitution with 60/40 acetonitrile/water (v/v); and (8) analysis by LC/MS/MS. Using this method, we detected in all three of our test soils, endogenous concentrations of all of our PFCA analytes, C(6) through C(10)-the lowest concentrations being roughly 30 pg/g of dry soil for perfluorinated hexanoic and decanoic acids in an agricultural soil.

  4. Rapid determination of ions by combined solid-phase extraction--diffuse reflectance spectroscopy

    NASA Technical Reports Server (NTRS)

    Fritz, James S.; Arena, Matteo P.; Steiner, Steven A.; Porter, Marc D.

    2003-01-01

    We introduce colorimetric solid-phase extraction (C-SPE) for the rapid determination of selected ions. This new technique links the exhaustive concentration of an analyte by SPE onto a membrane disk surface for quantitative measurement with a hand-held diffuse reflectance spectrometer. The concentration/measurement procedure is complete in approximately 1 min and can be performed almost anywhere. This method has been used to monitor iodine and iodide in spacecraft water in the 0.1-5.0 ppm range and silver(I) in the range of 5.0-1000 microg/l. Applications to the trace analysis of copper(II), nickel(II), iron(III) and chromium(VI) are described. Studies on the mechanism of extraction showed that impregnation of the disk with a surfactant as well as a complexing reagent results in uptake of additional water, which markedly improves the extraction efficiency.

  5. Synthesis and hydration behavior of calcium zirconium aluminate (Ca{sub 7}ZrAl{sub 6}O{sub 18}) cement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kang, Eun-Hee; Yoo, Jun-Sang; Kim, Bo-Hye

    2014-02-15

    Calcium zirconium aluminate (Ca{sub 7}ZrAl{sub 6}O{sub 18}) cements were prepared by solid state reaction and polymeric precursor methods, and their phase evolution, morphology, and hydration behavior were investigated. In polymeric precursor method, a nearly single phase Ca{sub 7}ZrAl{sub 6}O{sub 18} was obtained at relatively lower temperature (1200 °C) whereas in solid state reaction, a small amount of CaZrO{sub 3} coexisted with Ca{sub 7}ZrAl{sub 6}O{sub 18} even at higher temperature (1400 °C). Unexpectedly, Ca{sub 7}ZrAl{sub 6}O{sub 18} synthesized by polymeric precursor process was the large-sized and rough-shaped powder. The planetary ball milling was employed to control the particle size and shape.more » The hydration behavior of Ca{sub 7}ZrAl{sub 6}O{sub 18} was similar to that of Ca{sub 3}Al{sub 2}O{sub 6} (C3A), but the hydration products were Ca{sub 3}Al{sub 2}O{sub 6}·6H{sub 2}O (C3AH6) and several intermediate products. Thus, Zr (or ZrO{sub 2}) stabilized the intermediate hydration products of C3A.« less

  6. Characterization of Human Skin Emanations by Solid Phase Microextraction (SPME) Extraction of Volatiles and Subsequent Analysis by Gas Chromatography-Mass Spectrometry (GC-MS)

    DTIC Science & Technology

    2005-05-06

    Figure 12: Overlaid TICs of Multiple Extractions for Donor 18 Figure 13: Two Sets of Twins on Same Day Figure 14: Sectioning of Socks for Sock Odors ...considerations they provoked, i.e. sock odors , induced perspiration, Twister® extraction, and glass beads rubbed on hands (which was ultimately...Substances 2.1.2.1 Socks Worn on Feet for Three to Four Hours To test the viability of collecting odors from fragments of clothing, an experiment was

  7. Comparison of the solid-phase extraction efficiency of a bounded and an included cyclodextrin-silica microporous composite for polycyclic aromatic hydrocarbons determination in water samples.

    PubMed

    Mauri-Aucejo, Adela; Amorós, Pedro; Moragues, Alaina; Guillem, Carmen; Belenguer-Sapiña, Carolina

    2016-08-15

    Solid-phase extraction is one of the most important techniques for sample purification and concentration. A wide variety of solid phases have been used for sample preparation over time. In this work, the efficiency of a new kind of solid-phase extraction adsorbent, which is a microporous material made from modified cyclodextrin bounded to a silica network, is evaluated through an analytical method which combines solid-phase extraction with high-performance liquid chromatography to determine polycyclic aromatic hydrocarbons in water samples. Several parameters that affected the analytes recovery, such as the amount of solid phase, the nature and volume of the eluent or the sample volume and concentration influence have been evaluated. The experimental results indicate that the material possesses adsorption ability to the tested polycyclic aromatic hydrocarbons. Under the optimum conditions, the quantification limits of the method were in the range of 0.09-2.4μgL(-1) and fine linear correlations between peak height and concentration were found around 1.3-70μgL(-1). The method has good repeatability and reproducibility, with coefficients of variation under 8%. Due to the concentration results, this material may represent an alternative for trace analysis of polycyclic aromatic hydrocarbons in water trough solid-phase extraction. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Measurement of phenols dearomatization via electrolysis: the UV-Vis solid phase extraction method.

    PubMed

    Vargas, Ronald; Borrás, Carlos; Mostany, Jorge; Scharifker, Benjamin R

    2010-02-01

    Dearomatization levels during electrochemical oxidation of p-methoxyphenol (PMP) and p-nitrophenol (PNP) have been determined through UV-Vis spectroscopy using solid phase extraction (UV-Vis/SPE). The results show that the method is satisfactory to determine the ratio between aromatic compounds and aliphatic acids and reaction kinetics parameters during treatment of wastewater, in agreement with results obtained from numerical deconvolution of UV-Vis spectra. Analysis of solutions obtained from electrolysis of substituted phenols on antimony-doped tin oxide (SnO(2)--Sb) showed that an electron acceptor substituting group favored the aromatic ring opening reaction, preventing formation of intermediate quinone during oxidation. (c) 2009 Elsevier Ltd. All rights reserved.

  9. A rapid solid-phase extraction fluorometric method for thiamine and riboflavin in salmonid eggs

    USGS Publications Warehouse

    Zajicek, James L.; Tillitt, Donald E.; Brown, Scott B.; Brown, Lisa R.; Honeyfield, Dale C.; Fitzsimons, John D.

    2005-01-01

    A new method has been developed and successfully applied to the selective measurement of thiamine (nonphosphorylated), total thiamine (sum of thiamine, thiamine monophosphate [TMP], thiamine diphosphate [TDP], and thiamine triphosphate [TTP]), and potentially interfering riboflavin in acidic (2% trichloroacetic acid) extracts of selected salmonid and walleye egg samples. Acidic extracts of eggs were applied directly to end-capped C18, reversed-phase solid-phase extraction (SPE) columns and separated into three fractions by elution with mixtures of PO4 buffer (pH 2), methanol (10%), and acetonitrile (20%). All thiamine compounds recovered in the first two fractions were oxidized to their corresponding thiochromes with alkaline potassium hexacyanoferrate, and we measured the thiochrome fluorescence (excitation at 360 nm, emission at 460 nm) in a 96-well microplate reader. Riboflavin, recovered in third fraction (eluted with pH 2, 20% acetonitrile), was analyzed directly by measuring the fluorescence of this fraction (excitation at 450 nm, emission at 530 nm). Significant portions of the phosphate esters of thiamine (TMP, TDP, and presumably TTP), when present at low concentrations (< 10 nmol of total -thiamine per gram of egg), were not retained by the 100-mg SPE column, and were collected directly during sample loading and in a subsequent phosphoric acid rinse as fraction 1. Free thiamine (nonphosphorylated) and remaining portions of the TDP and TMP were then eluted in the second fraction with 10% methanol/PO4 buffer, whereas the un-ionized, relatively nonpolar riboflavin was eluted in the third fraction with 20% acetonitrile. This new method uses a traditional sample homogenization of egg tissue to extract thiamine compounds into 2% trichlororacetic acid solution; an inexpensive, commercially available SPE column; small amounts of sample (0.5-1 g); microliter volumes of solvents per sample; a traditional, relatively nonhazardous, oxidation of thiamine compounds to fluorescent thiochromes; and an ultraviolet-visible-wavelength-filter fluorometer for the measurements. ?? Copyright by the American Fisheries Society 2005.

  10. Application of Colorimetric Solid Phase Extraction (C-SPE) to Monitoring Nickel(II) and Lead(II) in Spacecraft Water Supplies

    NASA Technical Reports Server (NTRS)

    Diaz, Neil C.; Gazda, Daniel B.; Fritz, James S.; Porter, Marc D.; Rutz, Jeff; Mudgett, Paul; Schultz, John

    2004-01-01

    Archived water samples collected on the International Space Station (ISS) and returned to Earth for analysis have, in a few instances, contained trace levels of heavy metals. Building on our previous advances using Colorimetric Solid Phase Extraction (C-SPE) as a biocide monitoring technique, we are devising methods for the low level monitoring of nickel(II), lead(II) and other heavy metals. C-SPE is a sorption-spectrophotometric platform based on the extraction of analytes onto a membrane impregnated with a colorimetric reagent that are then quantified on the surface of the membrane using a diffuse reflectance spectrophotometer. Along these lines, we have determined nickel(II) via complexation with dimethylglyoxime (DMG) and begun to examine the analysis of lead(II) by its reaction with 2,5- dimercapto-1,3,4-thiadiazole (DMTD) and 4-(2- pyridylazo)-resorcinol (PAR). These developments are also extending a new variant of C-SPE in which immobilized reagents are being incorporated into this methodology in order to optimize sample reaction conditions and to introduce the colorimetric reagent. This paper describes the status of our development of these two new methods.

  11. Quantification of VX Nerve Agent in Various Food Matrices by Solid-Phase Extraction Ultra-Performance Liquid ChromatographyTime-of-Flight Mass Spectrometry

    DTIC Science & Technology

    2016-04-01

    QUANTIFICATION OF VX NERVE AGENT IN VARIOUS FOOD MATRICES BY SOLID-PHASE EXTRACTION ULTRA-PERFORMANCE...TITLE AND SUBTITLE Quantification of VX Nerve Agent in Various Food Matrices by Solid-Phase Extraction Ultra-Performance Liquid Chromatography... food matrices. The mixed-mode cation exchange (MCX) sorbent and Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) methods were used for

  12. Development of new method of δ13C measurement for trace hydrocarbons in natural gas using solid phase micro-extraction coupled to gas chromatography isotope ratio mass spectrometry.

    PubMed

    Li, Zhongping; Wang, Xibin; Li, Liwu; Zhang, Mingjie; Tao, Mingxin; Xing, Lantian; Cao, Chunhui; Xia, Yanqing

    2014-11-01

    Compound specific isotope analysis (CSIA) of normal-level hydrocarbons (C 1 -C 4 ) in natural gas is often successfully used in natural gas origin identification and classification, but little progress so far has been made for trace level hydrocarbons (C 5 -C 14 ) in natural gas. In this study, we developed a method for rapid analysis of carbon isotopic ratios for trace hydrocarbons in natural gas samples. This method can be described as a combined approach characterized by solid phase micro-extraction (SPME) technique coupled to gas chromatography isotope ratio mass spectrometry (GC/IRMS). In this study, the CAR-PDMS fiber was chosen as the SPME adsorptive material after comparative experiments with other four fibers, and the parameters, including equilibration time, extraction temperature and desorption time, for efficient extraction of trace hydrocarbons were systematically optimized. The results showed the carbon isotopic fractionation was not observed as a function of equilibration time and extraction temperature. And the δ 13 C signatures determined by SPME-GC/IRMS were in good agreement with the known δ 13 C values of C 5 -C 14 measured by GC-IRMS, and the accuracy is generally within ±0.5‰. Five natural gas samples were analyzed using this method, and the δ 13 C values for C 5 -C 14 components were obtained with satisfied repeatability. The SPME-GC/IRMS approach fitted with CAR-PDMS fiber is well suited for the preconcentration of trace hydrocarbons and provides so far the most reliable carbon isotopic analysis for trace compounds in natural gas. Published by Elsevier B.V.

  13. Magnetic solid phase extraction of brominated flame retardants and pentachlorophenol from environmental waters with carbon doped Fe3O4 nanoparticles

    NASA Astrophysics Data System (ADS)

    Yang, Jing; Li, Jia-yuan; Qiao, Jun-qin; Cui, Shi-hai; Lian, Hong-zhen; Chen, Hong-yuan

    2014-12-01

    Carbon doped Fe3O4 nanoparticles (Fe3O4/C) prepared by a facile hydrothermal reaction of glucose with iron resource have been applied as magnetic solid-phase extraction (MSPE) sorbent, for the first time, to extract trace brominated flame retardants (BFRs) and pentachlorophenol (PCP) from environmental waters. Various MSPE parameters were optimized including amount of Fe3O4/C nanoparticles, pH of sample solution, enrichment factor of analytes and reusability of Fe3O4/C sorbent. The reliability of the MSPE method was evaluated by the recoveries of BFRs and PCP in spiked water samples. Good recoveries (80.0-110.0%) were achieved with the relative standard deviations range from 0.3% to 6.8%. In this paper, the extraction characteristics of Fe3O4/C sorbent were further elucidated. It is found that the adsorption process of Fe3O4/C to analytes predominates the MSPE efficiency. There is hybrid hydrophobic interaction and hydrogen bonding or dipole-dipole attraction between Fe3O4/C and analytes. Notably, the chemical components of carbon layer on the surface of Fe3O4 nanoparticles were identified by X-ray photoelectron spectroscopy and thermogravimetry-mass spectrometry, and in consequence the covalent bonds between Fe3O4 and the coated carbon have been observed. In addition, the straight influence of synthesis condition of Fe3O4/C nanoparticles including glucose concentration and hydrothermal reaction time on extraction performance for BFRs and PCP has been investigated. It is confirmed that the existence of organic carbon containing functional groups over Fe3O4/C sorbent is responsible for the MSPE extraction.

  14. Separation of phenolic acids from sugarcane rind by online solid-phase extraction with high-speed counter-current chromatography.

    PubMed

    Geng, Ping; Fang, Yingtong; Xie, Ronglong; Hu, Weilun; Xi, Xingjun; Chu, Qiao; Dong, Genlai; Shaheen, Nusrat; Wei, Yun

    2017-02-01

    Sugarcane rind contains some functional phenolic acids. The separation of these compounds from sugarcane rind is able to realize the integrated utilization of the crop and reduce environment pollution. In this paper, a novel protocol based on interfacing online solid-phase extraction with high-speed counter-current chromatography (HSCCC) was established, aiming at improving and simplifying the process of phenolic acids separation from sugarcane rind. The conditions of online solid-phase extraction with HSCCC involving solvent system, flow rate of mobile phase as well as saturated extent of absorption of solid-phase extraction were optimized to improve extraction efficiency and reduce separation time. The separation of phenolic acids was performed with a two-phase solvent system composed of butanol/acetic acid/water at a volume ratio of 4:1:5, and the developed online solid-phase extraction with HSCCC method was validated and successfully applied for sugarcane rind, and three phenolic acids including 6.73 mg of gallic acid, 10.85 mg of p-coumaric acid, and 2.78 mg of ferulic acid with purities of 60.2, 95.4, and 84%, respectively, were obtained from 150 mg sugarcane rind crude extracts. In addition, the three different elution methods of phenolic acids purification including HSCCC, elution-extrusion counter-current chromatography and back-extrusion counter-current chromatography were compared. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Comparative evaluation of maceration and ultrasonic-assisted extraction of phenolic compounds from fresh olives.

    PubMed

    Deng, Junlin; Xu, Zhou; Xiang, Chunrong; Liu, Jing; Zhou, Lijun; Li, Tian; Yang, Zeshen; Ding, Chunbang

    2017-07-01

    Ultrasonic-assisted extraction (UAE) and maceration extraction (ME) were optimized using response surface methodology (RSM) for total phenolic compounds (TPC) from fresh olives. The main phenolic compounds and antioxidant activity of TPC were also investigated. The optimized result for UAE was 22mL/g of liquid-solid ratio, 47°C of extraction temperature and 30min of extraction time, 7.01mg/g of yielding, and for ME was 24mL/g of liquid-solid ratio, 50°C of extraction temperature and 4.7h of extraction time, 5.18mg/g of yielding. The HPLC analysis revealed that the extracts by UAE and ME possessed 14 main phenolic compounds, and UAE exhibited more amounts of all phenols than ME. The most abundant phenolic compounds in olive extracts were hydroxytyrosol, oleuropein and rutin. Both extracts showed excellent antioxidant activity in a dose-dependent manner. Taken together, UAE could effectively increase the yield of phenolic compounds from olives. In addition these phenolic compounds could be used as a potential source of natural antioxidants. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Determination of 4-nonylphenol and 4-octylphenol in human blood samples by high-performance liquid chromatography with multi-electrode electrochemical coulometric-array detection.

    PubMed

    Inoue, K; Yoshimura, Y; Makino, T; Nakazawa, H

    2000-11-01

    Alkylphenols can affect human health because they disrupt the endocrine system. In this study, an analytical method for determining trace amounts of 4-nonylphenol (NP) and 4-octylphenol (OP) in human blood samples was developed. Reversed-phase HPLC with multi-electrode electrochemical coulometric-array detection was used for the determination of NP and OP in plasma and serum samples prepared with a solid-phase extraction method. The separation was achieved using an isocratic mobile phase of 0.7% phosphoric acid-acetonitrile with a C18 reversed phase column. The detection limits of NP and OP were 1.0 and 0.5 ng ml-1, respectively. The recoveries of NP and OP added to human plasma samples were above 70.0% with a relative standard deviation of less than 15.5%. The method was found to be applicable to the determination of NP and OP in various human blood samples such as serum and plasma.

  17. An enhanced procedure for measuring organic acids and methyl esters in PM2.5

    NASA Astrophysics Data System (ADS)

    Liu, F.; Duan, F. K.; He, K. B.; Ma, Y. L.; Rahn, K. A.; Zhang, Q.

    2015-11-01

    A solid-phase extraction (SPE) pretreatment procedure allowing organic acids to be separated from methyl esters in fine aerosol has been developed. The procedure first separates the organic acids from fatty acid methyl esters (FAMEs) and other nonacid organic compounds by aminopropyl-based SPE cartridge and then quantifies them by gas chromatography/mass spectrometry. The procedure prevents the fatty acids and dimethyl phthalate from being overestimated, and so allows us to accurately quantify the C4-C11 dicarboxylic acids (DCAs) and the C8-C30 monocarboxylic acids (MCAs). Results for the extraction of DCAs, MCAs, and AMAs in eluate and FAMEs in effluate by SAX and NH2 SPE cartridges exhibited that the NH2 SPE cartridge gave higher extraction efficiency than the SAX cartridge. The recoveries of analytes ranged from 67.5 to 111.3 %, and the RSD ranged from 0.7 to 10.9 %. The resulting correlations between the aliphatic acids and FAMEs suggest that the FAMEs had sources similar to those of the carboxylic acids, or were formed by esterifying carboxylic acids, or that aliphatic acids were formed by hydrolyzing FAMEs. Through extraction and cleanup using this procedure, 17 aromatic acids in eluate were identified and quantified by gas chromatography/tandem mass spectrometry, including five polycyclic aromatic hydrocarbon (PAH): acids 2-naphthoic, biphenyl-4-carboxylic, 9-oxo-9H-fluorene-1-carboxylic, biphenyl-4,4´-dicarboxylic, and phenanthrene-1-carboxylic acid, plus 1,8-naphthalic anhydride. Correlations between the PAH acids and the dicarboxylic and aromatic acids suggested that the first three acids and 1,8-naphthalic anhydride were secondary atmospheric photochemistry products and the last two mainly primary.

  18. A Novel and Rapid Method to Determine Doxycycline in Human Plasma by Liquid Chromatography Tandem Mass Spectrometry

    PubMed Central

    Krishna, A. Chaitanya; Sathiyaraj, M.; Saravanan, R. S.; Chelladurai, R.; Vignesh, R.

    2012-01-01

    A simple, rapid, specific and sensitive liquid chromatography tandem mass spectrometric method has been developed and validated for the determination of doxycycline from the human plasma. Doxycycline is extracted from human plasma by solid phase extraction. Demeclocycline was used as an internal standard. Detection was performed at transitions of 444.800→428.200 for doxycycline and 464.700→448.100 for demeclocycline using mass spectrometry. Chromatographic separation of analyte and internal standard were carried out using a reverse phase C18, column at 0.500 ml/min flow. The assay of doxycycline is linear over the range of 0.055-7.612 μg/ml, with a precision <14.83%, regression coefficient (r2)=0.9961 and the limit of quantification in plasma for doxycycline was 0.055 μg/ml. Mean extraction recovery obtained was 95.55%. Samples are stable at room temperature for 6 h, processed samples were stable at least for 30.20 h and also stable at three freeze-thaw cycles. The method has been used to perform pharmacokinetic and bioequivalence studies in human plasma. PMID:23798780

  19. Quantitative analysis of three chiral pesticide enantiomers by high-performance column liquid chromatography.

    PubMed

    Wang, Peng; Liu, Donghui; Gu, Xu; Jiang, Shuren; Zhou, Zhiqiang

    2008-01-01

    Methods for the enantiomeric quantitative determination of 3 chiral pesticides, paclobutrazol, myclobutanil, and uniconazole, and their residues in soil and water are reported. An effective chiral high-performance liquid chromatographic (HPLC)-UV method using an amylose-tris(3,5-dimethylphenylcarbamate; AD) column was developed for resolving the enantiomers and quantitative determination. The enantiomers were identified by a circular dichroism detector. Validation involved complete resolution of each of the 2 enantiomers, plus determination of linearity, precision, and limit of detection (LOD). The pesticide enantiomers were isolated by solvent extraction from soil and C18 solid-phase extraction from water. The 2 enantiomers of the 3 pesticides could be completely separated on the AD column using n-hexane isopropanol mobile phase. The linearity and precision results indicated that the method was reliable for the quantitative analysis of the enantiomers. LODs were 0.025, 0.05, and 0.05 mg/kg for each enantiomer of paclobutrazol, myclobutanil, and uniconazole, respectively. Recovery and precision data showed that the pretreatment procedures were satisfactory for enantiomer extraction and cleanup. This method can be used for optical purity determination of technical material and analysis of environmental residues.

  20. Determination of 10 sulfonamide residues in meat samples by liquid chromatography with ultraviolet detection.

    PubMed

    Di Sabatino, Marcello; Di Pietra, Anna Maria; Benfenati, Luigi; Di Simone, Bruno

    2007-01-01

    A liquid chromatography (LC) method is described for the simultaneous determination of 10 commonly used sulfonamide drug residues in meat. The 10 sulfonamide drugs of interest were sulfadiazine, sulfathiazole, sulfamerazine, sulfadimidine, sulfamethizole, sulfamonomethoxine, sulfachloropyridazine, sulfadoxine, sulfadimethoxine, and sulfaquinoxaline. The residues were extracted with acetone-chloroform (1 + 1). Sulfonamides were quantitatively retained in the extracting solution and afterwards eluted from a cation-exchanger solid-phase extraction cartridge with a solution of methanol-aqueous ammonia. The solution was dried, reconstituted with 5 mL methanol and filtered before analysis by LC-ultraviolet using a C18 column with a mobile phase gradient of potassium dihydrogen phosphate buffer, pH 2.5, and methanol-acetonitrile (30 + 70, v/v). The method was applied to cattle, swine, chicken, and sheep muscle tissues. The validation was performed with a fortified cattle meat sample at level of 100 ppb, which is the administrative maximum residue limit for sulfonamides in the European Union. The limit of quantitation for all sulfonamides was between 3 and 14 ppb. Recovery was evaluated for different meat matrixes. The mean recovery values were between 66.3% for pork meat samples and 71.5% for cattle meat samples.

  1. Improvement of Nicotinic Acid and Nicotinamide Analysis in Meats and Meat Products by HPLC and LC-MS/MS with Solid-Phase Extraction.

    PubMed

    Hiki, Asako; Yamajima, Yukiko; Uematsu, Yoko

    2016-01-01

    A method for nicotinic acid (NA) and nicotinamide (NAA) analysis in meats was developed. NA and NAA were extracted from meats or meat products with metaphosphate aqueous solution. The extract was cleaned up with an Oasis MCX cartridge. The cartridge was washed with 2% acetic acid (v/v) and acetic acid-methanol solution. NA and NAA were eluted with ammonia-methanol solution. NA and NAA in the eluate were chromatographed on a Scherzo SM-C18 (3.0×150 mm, 3.0 μm) column with 20 mmol/L ammonium acetate containing 0.1% acetic acid-acetonitrile (97 : 3) as a mobile phase and were monitored at 261 nm. Quantification was performed by LC and LC-MS/MS. Calibration curves showed high linearity (correlation coefficient>0.998) between 1-25 μg/mL for LC and LC-MS/MS. Recoveries were 84-108% (CV≦5.8%) by HPLC and 79-105% (CV≦9.0%) by LC-MS/MS. The limit of quantitation for NA was 0.005-0.01 g/kg and that for NAA was 0.01-0.02 g/kg.

  2. Determination of perfluorinated carboxylic acids in fish fillet by micro-solid phase extraction, followed by liquid chromatography-triple quadrupole mass spectrometry.

    PubMed

    Lashgari, Maryam; Lee, Hian Kee

    2014-11-21

    In the current study, a simple, fast and efficient combination of protein precipitation and micro-solid phase extraction (μ-SPE) followed by liquid chromatography-triple quadrupole tandem mass spectrometry (LC-MS/MS) was developed for the determination of perfluorinated carboxylic acids (PFCAs) in fish fillet. Ten PFCAs with different hydrocarbon chain lengths (C5-C14) were analysed simultaneously using this method. Protein precipitation by acetonitrile and μ-SPE by surfactant-incorporated ordered mesoporous silica were applied to the extraction and concentration of the PFCAs as well as for removal of interferences. Determination of the PFCAs was carried out by LC-MS/MS in negative electrospray ionization mode. MS/MS parameters were optimized for multiple reaction monitoring of the analytes. (13)C mass labelled PFOA as a stable-isotopic internal standard, was used for calibration. The detection limits of the method ranged from 0.97 ng/g to 2.7 ng/g, with a relative standard deviation of between 5.4 and 13.5. The recoveries were evaluated for each analyte and were ranged from 77% to 120%. The t-test at 95% confidence level showed that for all the analytes, the relative recoveries did not depend on their concentrations in the explored concentration range. The effect of the matrix on MS signals (suppression or enhancement) was also evaluated. Contamination at low levels was detected for some analytes in the fish samples. The protective role of the polypropylene membrane used in μ-SPE in the elimination of matrix effects was evaluated by parallel experiments in classical dispersive solid phase extraction. The results evidently showed that the polypropylene membrane was significantly effective in reducing matrix effects. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. [Simultaneous determination of 6 pesticides in drinking water by high performance liquid chromatography-tandem mass spectrometry with solid phase extraction].

    PubMed

    Liu, Hua-liang; Wang, Lian-hong

    2013-05-01

    To develop an analytical method for simultaneous determination of 6 pesticides, namely bentazone, 2,4-dichlorophenoxyacetic acid,carbofuran, carbaryl, atrazine and pentachlorophenol, in drinking water by high performance liquid chromatography-tandem mass spectrometry, and thereby to provide a reference to revise the Health Standards for Drinking Water (GB/T 5750-2006). Meanwhile, to evaluate the content of the above 6 pesticides in the drinking water samples supplied by 12 centralized water plants in Jiangsu province. The 10 ml water sample was acidized by hydrochloric acid to pH ≤ 2, and then concentrated by solid phase extraction cartridge and eluted with acetone. The solvent was changed into methanol after drying by nitrogen blow. The target compounds were separated by C18 column using methanol/water as mobile phase, and detected by mass spectrometry with multi-reaction-monitoring(MRM) mode. The repeatability and sensitivity of the assay were evaluated. The drinking water samples from the 12 water plants were then detected. In this experimental method, the minimum detectable concentration were around 0.02-0.41 µg/L, with the recovery rate at 75%-115%, and the RSD between 2% and 10%. Under the experimental condition, there were no pesticides detected in the drinking water samples from the 12 centralized water plants. The method is efficient and environment-friendly, with little discharge of effluent, which could meet the requirement of the drinking water monitor.

  4. Diethylstilbestrol in fish tissue determined through subcritical fluid extraction and with GC-MS

    NASA Astrophysics Data System (ADS)

    Qiao, Qinghui; Shi, Nianrong; Feng, Xiaomei; Lu, Jie; Han, Yuqian; Xue, Changhu

    2016-06-01

    As the key point in sex hormone analysis, sample pre-treatment technology has attracted scientists' attention all over the world, and the development trend of sample preparation forwarded to faster and more efficient technologies. Taking economic and environmental concerns into account, subcritical fluid extraction as a faster and more efficient method has stood out as a sample pre-treatment technology. This new extraction technology can overcome the shortcomings of supercritical fluid and achieve higher extraction efficiency at relatively low pressures and temperatures. In this experiment, a simple, sensitive and efficient method has been developed for the determination of diethylstilbestrol (DES) in fish tissue using subcritical 1,1,1,2-tetrafluoroethane (R134a) extraction in combination with gas chromatography-mass spectrometry (GC-MS). After extraction, freezing-lipid filtration was utilized to remove fatty co-extract. Further purification steps were performed with C18 and NH2 solid phase extraction (SPE). Finally, the analyte was derived by heptafluorobutyric anhydride (HFBA), followed by GC-MS analysis. Response surface methodology (RSM) was employed to optimizing the extraction condition, and the optimized was as follows: extraction pressure, 4.3 MPa; extraction temperature, 26°C; amount of co-solvent volume, 4.7 mL. Under this condition, at a spiked level of 1, 5, 10 μg kg-1, the mean recovery of DES was more than 90% with relative standard deviations (RSDs) less than 10%. Finally, the developed method has been successfully used to analyzing the real samples.

  5. Long-term batch study of sorption, transformation and extractability to characterize the fate of the veterinary antibiotic sulfadiazine

    NASA Astrophysics Data System (ADS)

    Sittig, Stephan; Kasteel, Roy; Groeneweg, Joost; Vereecken, Harry

    2010-05-01

    The occurrence of veterinary antibiotic substances in various environmental compartments is of growing concern. Once released into the environment (e.g. via manure), these organic substances can cause changes in the composition of microbial populations, provoke the development and spreading of resistance genes and finally reach the food chain. The substance under study is the veterinary antibiotic sulfadiazine (SDZ), which belongs to the chemical group of the sulfonamides. These compounds are widely applied in animal husbandry. There are hardly any studies on the macroscopic sorption and desorption behaviour in combination with transformation processes, particularly investigating the sorbed fraction. We are conducting long-term batch sorption experiments to characterize the partitioning between the liquid and the solid phases as well as formation of transformation products. A sequential extraction procedure enables us to analyse the composition of the various sorbed fractions. We applied 14C-labelled SDZ in aqueous solution to fresh soil, originating from an agricultural field (silty loam). Adsorption and desorption studies are conducted for the duration of 60 d and 80 d, respectively. Unique setups for single time-steps allow us to trace the development of the partition process between the liquid and the solid phase and also partitioning within the solid phase. The composition of these liquid phases concerning the parent substance and the transformation products is analyzed. Using Radio-HPLC we find at least five transformation products: 4-hydroxy-sulfadiazine (4-OH-SDZ), 4-(2-iminopyrimidin-1(2H)-yl)-aniline (An-SDZ) and additionally three yet unknown products. By means of a sequential extraction, differently strong bound fractions of the compound can be distinguished. Extractions consist of a mild method (0.01 M CaCl2-solution; 24 h) followed by a methanol extraction (4 h). Finally, a residual fraction is gained by microwave extraction at an elevated temperature (150°C) and pressure (mixture of water and acetonitril, 4:1). Bound residues are determined by combustion. The course of the kinetic adsorption/desorption processes as well as the partitioning of the compound over the various solid phase fractions is observed. Sorption is time-dependent and strongly non-linear. The topsoil shows a significantly higher sorption affinity than the subsoil. While the amount of radioactivity sorbed to the soil matrix increases with time, the extractability decreases significantly, i. e. at the end of the experimental time there is no yield with mild extraction methods. On the contrary, after 60 d, there is still a considerably mass gained with the microwave extraction. Desorption is very slow due to hysteresis. In the topsoil transformation occurs with higher rates, leading to more detectable transformation products as in the subsoil. With our experimental setup it will be possible to set up a kinetic modell for the partitioning of the solute between the liquid and the solid phase. This description will also include an estimation of the transformation parameters.

  6. An absorbing microwave micro-solid-phase extraction device used in non-polar solvent microwave-assisted extraction for the determination of organophosphorus pesticides.

    PubMed

    Wang, Ziming; Zhao, Xin; Xu, Xu; Wu, Lijie; Su, Rui; Zhao, Yajing; Jiang, Chengfei; Zhang, Hanqi; Ma, Qiang; Lu, Chunmei; Dong, Deming

    2013-01-14

    A single-step extraction-cleanup method, including microwave-assisted extraction (MAE) and micro-solid-phase extraction (μ-SPE), was developed for the extraction of ten organophosphorus pesticides in vegetable and fruit samples. Without adding any polar solvent, only one kind of non-polar solvent (hexane) was used as extraction solvent in the whole extraction step. Absorbing microwave μ-SPE device, was prepared by packing activated carbon with microporous polypropylene membrane envelope, and used as not only the sorbent in μ-SPE, but also the microwave absorption medium. Some experimental parameters effecting on extraction efficiency was investigated and optimized. 1.0 g of sample, 8 mL of hexane and three absorbing microwave μ-SPE devices were added in the microwave extraction vessel, the extraction was carried out under 400 W irradiation power at 60°C for 10 min. The extracts obtained by MAE-μ-SPE were directly analyzed by GC-MS without any clean-up process. The recoveries were in the range of 93.5-104.6%, and the relative standard deviations were lower than 8.7%. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. [Mechanism of gold solid extraction from aurocyanide solution using D3520 resin impregnated with TRPO].

    PubMed

    Yang, Xiang-Jun; Wang, Shi-Xiong; Zou, An-Qin; Chen, Jing; Guo, Hong

    2014-02-01

    Trialkyphosphine oxides (TRPO) was successfully used for the impregnation of D3520 resin to prepare an extractant-impregnated resin (EIR). Solid extraction of Au(I) from alkaline cyanide solution was studied using this extractant-impregnated resin (EIR), with addition of cetyltrimethylammonium bromide (CTMAB), directly into the aurous aqueous phase in advance. The mechanism of solid extraction was further investigated by means of FTIR, XPS and SEM. The column separation studies have shown that cationic surfactant CTMAB played a key role in the solid phase extraction, and the resin containing TRPO were effective for the extraction of gold when the molar ratio of CTMAB: Au( I ) reached 1:1. FTIR spectroscopy of gold loaded EIR showed that the frequency of C[triple bond]N stretching vibration was at 2144 cm(-1), and the frequency of P=O stretching vibration shifted to lower frequency from 1153 to 1150 cm(-1). The XPS spectrum of N(1s), Au(4f7/2) and Au(4f5/2) sugges- ted that the coordination environment of gold did not change before and after extraction, and gold was still as the form of Au (CN)2(-) anion exiting in the loaded resin; O(1s) spectrum showed that the chemically combined water significantly increased after solid extraction from 30.74% to 42.34%; Comparing to the P(2p) spectrum before and after extraction, the binding energy increased from 132. 15 to 132. 45 eV, indicating there maybe existing hydrogen-bond interaction between P=O and water molecule, such as P=O...H-O-H. The above results obtained established that in the solid extraction process, the hydrophobic ion association [CTMA+ x Au(CN)] diffused from the bulk solution into the pores of the EIR, and then be solvated by TRPO adsorbed in the pores through hydrogen bonding bridged by the water molecules.

  8. Aptamer-functionalized Fe3 O4 magnetic nanoparticles as a solid-phase extraction adsorbent for the selective extraction of berberine from Cortex phellodendri.

    PubMed

    Jiang, Ling-Feng; Chen, Bo-Cheng; Chen, Ben; Li, Xue-Jian; Liao, Hai-Lin; Zhang, Wen-Yan; Wu, Lin

    2017-07-01

    The extraction adsorbent was fabricated by immobilizing the highly specific recognition and binding of aptamer onto the surface of Fe 3 O 4 magnetic nanoparticles, which not only acted as recognition elements to recognize and capture the target molecule berberine from the extract of Cortex phellodendri, but also could favor the rapid separation and purification of the bound berberine by using an external magnet. The developed solid-phase extraction method in this work was useful for the selective extraction and determination of berberine in Cortex phellodendri extracts. Various conditions such as the amount of aptamer-functionalized Fe 3 O 4 magnetic nanoparticles, extraction time, temperature, pH value, Mg 2+ concentration, elution time and solvent were optimized for the solid-phase extraction of berberine. Under optimal conditions, the purity of berberine extracted from Cortex phellodendri was as high as 98.7% compared with that of 4.85% in the extract, indicating that aptamer-functionalized Fe 3 O 4 magnetic nanoparticles-based solid-phase extraction method was very effective for berberine enrichment and separation from a complex herb extract. The applicability and reliability of the developed solid-phase extraction method were demonstrated by separating berberine from nine different concentrations of one Cortex phellodendri extract. The relative recoveries of the spiked solutions of all the samples were between 95.4 and 111.3%, with relative standard deviations ranging between 0.57 and 1.85%. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Determination of thiram in natural waters using flow-injection with cerium(IV)-quinine chemiluminescence system.

    PubMed

    Waseem, Amir; Yaqoob, Mohammad; Nabi, Abdul

    2010-01-01

    A simple and rapid flow-injection chemiluminescence method has been developed for the determination of dithiocarbamate fungicide thiram based on the chemiluminescence reaction of thiram with ceric sulfate and quinine in aqueous sulfuric acid. The present method allowed the determination of thiram in the concentration range of 7.5-2500 ng/mL and the detection limit (signal-to-noise ratio = 3) was 7.5 ng/mL with sample throughput of 120/h. The relative standard deviation was 2.5% for 10 replicate analyses of 500 ng/mL thiram. The effects of foreign species including various anions and cations present in water at environmentally relevant concentrations and some pesticides were also investigated. The proposed method was applied to determine thiram in spiked natural waters using octadecyl bonded phase silica (C(18)) cartridges for solid-phase extraction. The recoveries were in the range 99 +/- 1 to 104 +/- 1%. Copyright (c) 2009 John Wiley & Sons, Ltd.

  10. Determination of acaricide residues in saudi arabian honey and beeswax using solid phase extraction and gas chromatography.

    PubMed

    Kamel, Alaa; Al-Ghamdi, Ahmad

    2006-01-01

    Determination of acaricide residues of flumethrin, tau-fluvalinate, coumaphos, and amitraz in honey and beeswax was carried out using a rapid extraction method utilizing C-18 SPE cartridges and an analytical method utilizing GC with ECD, NPD, and MSD detectors for the four acaricides. Recovery percentages from the extraction method ranged from 90-102%, while the minimum detection levels ranged from 0.01-0.05 mg/kg for the acaricides. Nine of the 21 analyzed samples were found to be contaminated with the acaricides tau-fluvalinate and coumaphos. Neither flumethrin nor amitraz was detected in any of the honey or wax samples. Coumaphos was found only in honey samples in which two samples exceeded the tolerance levels set by EPA and EC regulations. It has not been detected in beeswax. Five honey samples and eight beeswax samples were found to be contaminated with tau-fluvalinate. One of the wax samples was contaminated with a relatively high residue of tau-fluvalinate and contained above 10 mg/kg.

  11. Liquid chromatographic determination of acriflavine and proflavine residues in channel catfish muscle.

    PubMed

    Plakas, S M; el Said, K R; Jester, E L; Bencsath, F A; Hayton, W L

    1997-01-01

    A liquid chromatographic (LC) method was developed for determination of acriflavine (ACR) and proflavine (PRO) residues in channel catfish muscle. Residues were extracted with acidified methanol solution, and extracts were cleaned up with C18 solid-phase extraction columns. Residue concentrations were determined on an LC cyano column, with spectrophotometric detection at 454 nm. Catfish muscle was individually fortified with ACR (purified from commercial product) and PRO at concentrations of 5, 10, 20, 40, and 80 ppb (5 replicates per level). Mean recoveries from fortified muscle at each level ranged from 86 to 95%, with relative standard deviations (RSDs) of 2.5 to 5.7%. The method was applied to incurred residues of ACR and PRO in muscle after waterborne exposure of channel catfish to commercial acriflavine (10 ppm total dye for 4 h). RSDs for incurred residues of ACR and PRO were in the same range as those for fortified muscle. Low residue concentrations (< 1% of exposure water concentration) suggested poor absorption of ACR and PRO in catfish.

  12. New method for determination of ten pesticides in human blood.

    PubMed

    García-Repetto, R; Giménez, M P; Repetto, M

    2001-01-01

    An analytical method was developed for precise identification and quantitation of 10 pesticides in human blood. The pesticides studied, which have appeared frequently in actual cases, were endosulfan, lindane, parathion, ethyl-azinphos, diazinon, malathion, alachlor, tetradifon, fenthion and dicofol (o-p' and p-p' isomers). The current method replaces an earlier method which involved liquid-liquid extraction with a mixture of n-hexane-benzene (1 + 1). The extraction is performed by solid-phase extraction, with C18 cartridges and 2 internal standards, perthane and triphenylphosphate. Eluates were analyzed by gas chromatography (GC) with nitrogen-phosphorus and electrochemical detectors. Results were confirmed by GC-mass spectrometry in the electron impact mode. Blood blank samples spiked with 2 standard mixtures and an internal standard were used for quantitation. Mean recoveries ranged from 71.83 to 97.10%. Detection and quantitation limits are reported for each pesticide. Examples are provided to show the application of the present method to actual samples.

  13. Simultaneous determination of mequindox, quinocetone, and their major metabolites in chicken and pork by UPLC-MS/MS.

    PubMed

    Li, Yanshen; Liu, Kaili; Beier, Ross C; Cao, Xingyuan; Shen, Jianzhong; Zhang, Suxia

    2014-10-01

    This report presents a UPLC-MS/MS method for determination of mequindox (MEQ), quinocetone (QCT) and their 11 metabolites in chicken and pork samples. Following extraction process with acetonitrile-ethyl acetate, acidulation, and re-extraction with ethyl acetate in turn, target analytes were further purified using C18 solid phase extraction (SPE) cartridges for UPLC-MS/MS analysis. Validation was processed with mean recoveries from 69.1% to 113.3% with intra-day relative standard deviation (RSD) <14.7%, inter-day RSD <19.2%, and limit of detection between 0.05 and 1.0 μg/kg for each analytes. The verified method was successfully applied to the quantitative determination of commercial samples. This developed procedure will help to control food animal products with MEQ and QCT residues, and facilitate further pharmacokinetic and residue studies of similar quinoxaline-1,4-dioxide veterinary drugs. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. High-throughput and selective solid-phase extraction of urinary catecholamines by crown ether-modified resin composite fiber.

    PubMed

    Chen, LiQin; Wang, Hui; Xu, Zhen; Zhang, QiuYue; Liu, Jia; Shen, Jun; Zhang, WanQi

    2018-08-03

    In the present study, we developed a simple and high-throughput solid phase extraction (SPE) procedure for selective extraction of catecholamines (CAs) in urine samples. The SPE adsorbents were electrospun composite fibers functionalized with 4-carboxybenzo-18-crown-6 ether modified XAD resin and polystyrene, which were packed into 96-well columns and used for high-throughput selective extraction of CAs in healthy human urine samples. Moreover, the extraction efficiency of packed-fiber SPE (PFSPE) was examined by high performance liquid chromatography coupled with fluorescence detector. The parameters affecting the extraction efficiency and impurity removal efficiency were optimized, and good linearity ranging from 0.5 to 400 ng/mL was obtained with a low limit of detection (LOD, 0.2-0.5 ng/mL) and a good repeatability (2.7%-3.7%, n = 6). The extraction recoveries of three CAs ranged from 70.5% to 119.5%. Furthermore, stable and reliable results obtained by the fluorescence detector were superior to those obtained by the electrochemical detector. Collectively, PFSPE coupled with 96-well columns was a simple, rapid, selective, high-throughput and cost-efficient method, and the proposed method could be applied in clinical chemistry. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Optimization of headspace solid-phase microextraction by means of an experimental design for the determination of methyl tert.-butyl ether in water by gas chromatography-flame ionization detection.

    PubMed

    Dron, Julien; Garcia, Rosa; Millán, Esmeralda

    2002-07-19

    A procedure for determination of methyl tert.-butyl ether (MTBE) in water by headspace solid-phase microextraction (HS-SPME) has been developed. The analysis was carried out by gas chromatography with flame ionization detection. The extraction procedure, using a 65-microm poly(dimethylsiloxane)-divinylbenzene SPME fiber, was optimized following experimental design. A fractional factorial design for screening and a central composite design for optimizing the significant variables were applied. Extraction temperature and sodium chloride concentration were significant variables, and 20 degrees C and 300 g/l were, respectively chosen for the best extraction response. With these conditions, an extraction time of 5 min was sufficient to extract MTBE. The calibration linear range for MTBE was 5-500 microg/l and the detection limit 0.45 microg/l. The relative standard deviation, for seven replicates of 250 microg/l MTBE in water, was 6.3%.

  16. Fully automated analysis of four tobacco-specific N-nitrosamines in mainstream cigarette smoke using two-dimensional online solid phase extraction combined with liquid chromatography-tandem mass spectrometry.

    PubMed

    Zhang, Jie; Bai, Ruoshi; Yi, Xiaoli; Yang, Zhendong; Liu, Xingyu; Zhou, Jun; Liang, Wei

    2016-01-01

    A fully automated method for the detection of four tobacco-specific nitrosamines (TSNAs) in mainstream cigarette smoke (MSS) has been developed. The new developed method is based on two-dimensional online solid-phase extraction-liquid chromatography-tandem mass spectrometry (SPE/LC-MS/MS). The two dimensional SPE was performed in the method utilizing two cartridges with different extraction mechanisms to cleanup disturbances of different polarity to minimize sample matrix effects on each analyte. Chromatographic separation was achieved using a UPLC C18 reversed phase analytical column. Under the optimum online SPE/LC-MS/MS conditions, N'-nitrosonornicotine (NNN), N'-nitrosoanatabine (NAT), N'-nitrosoanabasine (NAB), and 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK) were baseline separated with good peak shapes. This method appears to be the most sensitive method yet reported for determination of TSNAs in mainstream cigarette smoke. The limits of quantification for NNN, NNK, NAT and NAB reached the levels of 6.0, 1.0, 3.0 and 0.6 pg/cig, respectively, which were well below the lowest levels of TSNAs in MSS of current commercial cigarettes. The accuracy of the measurement of four TSNAs was from 92.8 to 107.3%. The relative standard deviations of intra-and inter-day analysis were less than 5.4% and 7.5%, respectively. The main advantages of the method developed are fairly high sensitivity, selectivity and accuracy of results, minimum sample pre-treatment, full automation, and high throughput. As a part of the validation procedure, the developed method was applied to evaluate TSNAs yields for 27 top-selling commercial cigarettes in China. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Rapid determination of chlormequat in meat by dispersive solid-phase extraction and hydrophilic interaction liquid chromatography (HILIC)-electrospray tandem mass spectrometry.

    PubMed

    Li, Chunmei; Jin, Fen; Yu, Zhiyong; Qi, Yamei; Shi, Xiaomei; Wang, Miao; Shao, Hua; Jin, Maojun; Wang, Jing; Yang, Mingqi

    2012-07-11

    A rapid method for analyzing trace levels of chlormequat (CQ) in meat samples by hydrophilic interaction liquid chromatography (HILIC)-electrospray tandem mass spectrometry was developed. The samples were extracted with acetonitrile, followed by a rapid cleanup through a dispersive solid-phase extraction (DSPE) technique with octadecyl (C18) DSPE sorbents. The chromatographic separation was achieved within 6 min using a HILIC column with 10 mM ammonium acetate and 0.1% (v/v) formic acid in water/acetonitrile (v/v, 40:60) as the mobile phase. Quantification was performed using a matrix-matched calibration curve, which was linear in the range of the 0.05-100 μg/L. The limit of detection (LOD) was estimated at 0.03 μg/kg for CQ on the basis of a peak to peak signal noise (S/N = 3). The limit of quantification (LOQ) was 0.1 μg/kg on the basis of the lowest spiked concentration with suitable precision and accuracy. The average recovery of CQ in spiked meat samples was 86.4-94.7% at 2, 20, and 200 μg/kg. Finally, this method was applied to determine CQ in the livestock and poultry meats purchased from markets in Beijing in 2011. CQ was detected in all 12 samples, and the concentration was 0.4-636.0 μg/kg. Concentrations in a chicken sample (636.0 μg/kg) and a goat meat sample (486.0 μg/kg) were found to be 15.9 and 2.43 times the corresponding Codex maximum residue limits, respectively.

  18. Solid-phase extraction of galloyl- and caffeoylquinic acids from natural sources (Galphimia glauca and Arnicae flos) using pure zirconium silicate and bismuth citrate powders as sorbents inside micro spin columns.

    PubMed

    Hussain, Shah; Schönbichler, Stefan A; Güzel, Yüksel; Sonderegger, Harald; Abel, Gudrun; Rainer, Matthias; Huck, Christian W; Bonn, Günther K

    2013-10-01

    Galloyl- and caffeoylquinic acids are among the most important pharmacological active groups of natural compounds. This study describes a pre-step in isolation of some selected representatives of these groups from biological samples. A selective solid-phase extraction (SPE) method for these compounds may help assign classes and isomer designations within complex mixtures. Pure zirconium silicate and bismuth citrate powders (325 mesh) were employed as two new sorbents for optimized SPE of phenolic acids. These sorbents possess electrostatic interaction sites which accounts for additional interactions for carbon acid moieties as compared to hydrophilic and hydrophobic sorbents alone. Based on this principle, a selective SPE method for 1,3,4,5-tetragalloylquinic acid (an anti-HIV and anti-asthamatic agent) as a starting compound was developed and then deployed upon other phenolic acids with success. The recoveries and selectivities of both sorbents were compared to most commonly applied and commercially available sorbents by using high performance liquid chromatography. The nature of interaction between the carrier sorbent and the acidic target molecules was investigated by studying hydrophilic (silica), hydrophobic (C18), mixed-mode (ionic and hydrophobic: Oasis(®) MAX) and predominantly electrostatic (zirconium silicate) materials. The newly developed zirconium silicate and bismuth citrate stationary phases revealed promising results for the selective extraction of galloyl- and caffeoylquinic acids from natural sources. It was observed that zirconium silicate exhibited maximum recovery and selectivity for tetragalloylquinic acid (84%), chlorogenic acid (82%) and dicaffeoylquinic acid (94%) among all the tested sorbents. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. A rapid MCM-41 dispersive micro-solid phase extraction coupled with LC/MS/MS for quantification of ketoconazole and voriconazole in biological fluids.

    PubMed

    Yahaya, Noorfatimah; Sanagi, Mohd Marsin; Abd Aziz, Noorizan; Wan Ibrahim, Wan Aini; Nur, Hadi; Loh, Saw Hong; Kamaruzaman, Sazlinda

    2017-02-01

    A rapid dispersive micro-solid phase extraction (D-μ-SPE) combined with LC/MS/MS method was developed and validated for the determination of ketoconazole and voriconazole in human urine and plasma samples. Synthesized mesoporous silica MCM-41 was used as sorbent in d-μ-SPE of the azole compounds from biological fluids. Important D-μ-SPE parameters, namely type desorption solvent, extraction time, sample pH, salt addition, desorption time, amount of sorbent and sample volume were optimized. Liquid chromatographic separations were carried out on a Zorbax SB-C 18 column (2.1 × 100 mm, 3.5 μm), using a mobile phase of acetonitrile-0.05% formic acid in 5 mm ammonium acetate buffer (70:30, v/v). A triple quadrupole mass spectrometer with positive ionization mode was used for the determination of target analytes. Under the optimized conditions, the calibration curves showed good linearity in the range of 0.1-10,000 μg/L with satisfactory limit of detection (≤0.06 μg/L) and limit of quantitation (≤0.3 μg/L). The proposed method also showed acceptable intra- and inter-day precisions for ketoconazole and voriconazole from urine and human plasma with RSD ≤16.5% and good relative recoveries in the range 84.3-114.8%. The MCM-41-D-μ-SPE method proved to be rapid and simple and requires a small volume of organic solvent (200 μL); thus it is advantageous for routine drug analysis. Copyright © 2016 John Wiley & Sons, Ltd.

  20. Simultaneous determination of triptolide, tripdiolide and tripterine in human urine by high-performance liquid chromatography coupled with ion trap atmospheric-pressure chemical ionization mass spectrometry.

    PubMed

    Jin, Mi-cong; Chen, Xiao-hong; OuYang, Xiao-kun

    2009-03-01

    An accurate and selective method for the simultaneous determination of triptolide, tripdiolide and tripterine in human urine using hydrocortisone as an internal standard (IS) by high-performance liquid chromatography coupled with atmospheric-pressure chemical ionization mass spectrometry in negative ion mode has been developed. After triptolide, tripdiolide and tripterine in human urine were extracted with ethyl acetate and cleaned by solid-phase extraction with C(18) cartridges, a satisfactory separation was achieved on an XDB C(18) short column (30 x 2.1 mm i.d., 3 microm) using the mobile phase of acetic acid-ammonium acetate (5 mmol/L, pH = 4.5)-acetonitrile-methanol in gradient elution. Detection was operated by APCI in selected ion monitoring mode. The target ions m/z 359, m/z 375, m/z 449 and m/z 419 were selected for the quantification of triptolide, tripdiolide, tripterine and IS, respectively. The linear range was 1.0-100.0 ng mL(-1), and the limits of quantification in human urine were found to be 0.1-0.5 ng mL(-1) for the three compounds. The precisions (CV%) and accuracies were 6.6-12.9 and 85.1-97.0%, respectively. The developed method could be applied to the determination of triptolide, tripdiolide and tripterine in human urine for diagnosis of the intoxication and for forensic purposes. 2008 John Wiley & Sons, Ltd.

  1. Colorimetric-Solid Phase Extraction Technology for Water Quality Monitoring: Evaluation of C-SPE and Debubbling Methods in Microgravity

    NASA Technical Reports Server (NTRS)

    Hazen-Bosveld, April; Lipert, Robert J.; Nordling, John; Shih, Chien-Ju; Siperko, Lorraine; Porter, Marc D.; Gazda, Daniel B.; Rutz, Jeff A.; Straub, John E.; Schultz, John R.; hide

    2007-01-01

    Colorimetric-solid phase extraction (C-SPE) is being developed as a method for in-flight monitoring of spacecraft water quality. C-SPE is based on measuring the change in the diffuse reflectance spectrum of indicator disks following exposure to a water sample. Previous microgravity testing has shown that air bubbles suspended in water samples can cause uncertainty in the volume of liquid passed through the disks, leading to errors in the determination of water quality parameter concentrations. We report here the results of a recent series of C-9 microgravity experiments designed to evaluate manual manipulation as a means to collect bubble-free water samples of specified volumes from water sample bags containing up to 47% air. The effectiveness of manual manipulation was verified by comparing the results from C-SPE analyses of silver(I) and iodine performed in-flight using samples collected and debubbled in microgravity to those performed on-ground using bubble-free samples. The ground and flight results showed excellent agreement, demonstrating that manual manipulation is an effective means for collecting bubble-free water samples in microgravity.

  2. Carbon based thirty six atom spheres

    DOEpatents

    Piskoti, Charles R.; Zettl, Alex K.; Cohen, Marvin L.; Cote, Michel; Grossman, Jeffrey C.; Louie, Steven G.

    2005-09-06

    A solid phase or form of carbon is based on fullerenes with thirty six carbon atoms (C.sub.36). The C.sub.36 structure with D.sub.6h symmetry is one of the two most energetically favorable, and is conducive to forming a periodic system. The lowest energy crystal is a highly bonded network of hexagonal planes of C.sub.36 subunits with AB stacking. The C.sub.36 solid is not a purely van der Waals solid, but has covalent-like bonding, leading to a solid with enhanced structural rigidity. The solid C.sub.36 material is made by synthesizing and selecting out C.sub.36 fullerenes in relatively large quantities. A C.sub.36 rich fullerene soot is produced in a helium environment arc discharge chamber by operating at an optimum helium pressure (400 torr). The C.sub.36 is separated from the soot by a two step process. The soot is first treated with a first solvent, e.g. toluene, to remove the higher order fullerenes but leave the C.sub.36. The soot is then treated with a second solvent, e.g. pyridine, which is more polarizable than the first solvent used for the larger fullerenes. The second solvent extracts the C.sub.36 from the soot. Thin films and powders can then be produced from the extracted C.sub.36. Other materials are based on C.sub.36 fullerenes, providing for different properties.

  3. [Determination of lead in edible salt with solid-phase extraction and GFAAS].

    PubMed

    Zhao, Xin; Zhou, Shuang; Ma, Lan; Yang, Dajin

    2013-01-01

    Establishing a method for determination of lead in salt with solid-phase extraction and GFAAS. Salt sample was diluted to a certain volume directly with ammonium acetate, then the sample solution was filtered through the solid phase extraction column which has been pre-activated. Lead ions were retained, and the sodium chloride matrix was removed. After elution, the collected lead ions was determined by graphite furnace atomic absorption spectrometry in 257.4 nm. This method can be used effectively to wipe off the sodium chloride in matrix. The limit of detection was 0.7 microg/kg and the limit of quantification was 2 microg/kg. Solid phase extraction technique can be used effectively to reduce the interference in matrix and improves the accuracy and reproducibility of detection.

  4. Extraction and Analysis of Sulfur Mustard (HD) from Various Food Matrices by Gas ChromatographyMass Spectrometry

    DTIC Science & Technology

    2016-01-01

    EXTRACTION AND ANALYSIS OF SULFUR MUSTARD (HD) FROM VARIOUS FOOD MATRICES BY GAS CHROMATOGRAPHY–MASS...Sulfur Mustard (HD) from Various Food Matrices by Gas Chromatography–Mass Spectrometry 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT...spectrometry was used to analyze sulfur mustard (HD) in various food matrices. The development of a solid-phase extraction method using a normal

  5. Recent Application of Solid Phase Based Techniques for Extraction and Preconcentration of Cyanotoxins in Environmental Matrices.

    PubMed

    Mashile, Geaneth Pertunia; Nomngongo, Philiswa N

    2017-03-04

    Cyanotoxins are toxic and are found in eutrophic, municipal, and residential water supplies. For this reason, their occurrence in drinking water systems has become a global concern. Therefore, monitoring, control, risk assessment, and prevention of these contaminants in the environmental bodies are important subjects associated with public health. Thus, rapid, sensitive, selective, simple, and accurate analytical methods for the identification and determination of cyanotoxins are required. In this paper, the sampling methodologies and applications of solid phase-based sample preparation methods for the determination of cyanotoxins in environmental matrices are reviewed. The sample preparation techniques mainly include solid phase micro-extraction (SPME), solid phase extraction (SPE), and solid phase adsorption toxin tracking technology (SPATT). In addition, advantages and disadvantages and future prospects of these methods have been discussed.

  6. A new route of oxygen isotope exchange in the solid phase: demonstration in CuSO4.5H2O.

    PubMed

    Danon, Albert; Saig, Avraham; Finkelstein, Yacov; Koresh, Jacob E

    2005-11-10

    Temperature-programmed desorption mass spectrometry (TPD-MS) measurements on [(18)O]water-enriched copper sulfate pentahydrate (CuSO(4).5H(2)(18)O) reveal an unambiguous occurrence of efficient oxygen isotope exchange between the water of crystallization and the sulfate in its CuSO(4) solid phase. To the best of our knowledge, the occurrence of such an exchange was never observed in a solid phase. The exchange process was observed during the stepwise dehydration (50-300 degrees C) of the compound. Specifically, the exchange promptly occurs somewhere between 160 and 250 degrees C; however, the exact temperature could not be resolved conclusively. It is shown that only the fifth, sulfate-associated, anionic H(2)O molecule participates in the exchange process and that the exchange seems to occur in a preferable fashion with, at the most, one oxygen atom in SO(4). Such an exchange, occurring below 250 degrees C, questions the common conviction of unfeasible oxygen exchange under geothermic conditions. This new oxygen exchange phenomenon is not exclusive to copper sulfate but is unambiguously observed also in other sulfate- and nitrate-containing minerals.

  7. Extraction Methodological Contributions Toward Ultra-Performance Liquid ChromatographyTime-of-Flight Mass Spectrometry: Quantification of Free GB from Various Food Matrices

    DTIC Science & Technology

    2016-02-01

    SPECTROMETRY: QUANTIFICATION OF FREE GB FROM VARIOUS FOOD MATRICES ECBC-TR-1351 Sue Y. Bae Mark D. Winemiller RESEARCH AND TECHNOLOGY DIRECTORATE...Flight Mass Spectrometry: Quantification of Free GB from Various Food Matrices 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER...methylphosphonofluoridate (sarin, GB) in various food matrices. The development of a solid-phase extraction method using a normal-phase silica gel column for

  8. Simultaneous multiresidue determination of metronidazole and spiramycin in fish muscle using high performance liquid chromatography with UV detection.

    PubMed

    Maher, Hadir M; Youssef, Rasha M; Khalil, Riad H; El-Bahr, Sabry M

    2008-12-15

    An efficient multiresidue method for the simultaneous determination of metronidazole (MET) and spiramycin (SPY) in tilapia fish muscle, based on high performance liquid chromatography with UV detection (HPLC-UV), has been developed. The drugs were extracted with 0.2% orthophosphoric acid-methanol (6:4), and the extracts were cleaned up on a solid phase extraction cartridge, C18 Sep-Pak light column. The LC separation was performed on a RP stainless-steel C-18 analytical column (150 mm x 4.6 mm, 5 microm) with a gradient elution system of 0.05 M phosphate buffer adjusted to pH 2.4-acetonitrile as the mobile phase at the flow rate of 1.0 ml min(-1). A wavelength programming was applied for the UV detection of the analytes. The method not only enabled the determination of the parent drugs, MET and SPY, but also permitted the determination of their metabolites, hydroxymetronidazole (HMET) and neospiramycin (NSPY). The calibration graphs for each drug were rectilinear in the range of 0.005-1.000 microg g(-1) for MET and HMET and 0.025-1.000 microg g(-1) for SPY and NSPY. With this method, the cited drugs with their metabolites were determined in fortified fish muscle tissues at levels of 0.025, 0.1 and 1.0 microg g(-1) with good accuracy and precision. LOD and LOQ obtained for each drug were as follows: 0.002 and 0.005 microg g(-1) for MET and HMET and 0.005 and 0.025 microg g(-1) for SPY and NSPY. Utilization of the method to successfully analyze tilapia fish muscle samples incurred with MET and SPY was described.

  9. Pilot-scale bioconversion of rice and sunflower agro-residues into medicinal mushrooms and laccase enzymes through solid-state fermentation with Ganoderma lucidum.

    PubMed

    Postemsky, P D; Bidegain, M A; González-Matute, R; Figlas, N D; Cubitto, M A

    2017-05-01

    Solid-state fermentation was evaluated at the pilot-scale for the bioconversion and valorization of rice husks and straw (RSH), or sunflower seed hulls (SSH), into medicinal mushrooms and crude extracts, with laccase activity. The average mushroom yield was 56kg dry weight per ton of agro-residues. Laccase activity in crude aqueous extracts showed its maximum value of 10,927Ukg -1 in RSH (day 10, Exudate phase) and 16,442Ukg -1 in SSH (day 5, Full colonization phase), the activity at the Residual substrate phase being 511Ukg -1 in RSH and 803Ukg -1 in SSH, respectively. Crude extracts obtained with various protocols revealed differences in the extraction yields. Lyophilization followed by storage at 4°C allowed the preservation of laccase activity for more than one month. It is proposed that standard mushroom farms could increase their profits by obtaining laccase as a byproduct during the gaps in mycelium running. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Active Sampling Device for Determining Pollutants in Surface and Pore Water - the In Situ Sampler for Biphasic Water Monitoring

    NASA Astrophysics Data System (ADS)

    Supowit, Samuel D.; Roll, Isaac B.; Dang, Viet D.; Kroll, Kevin J.; Denslow, Nancy D.; Halden, Rolf U.

    2016-02-01

    We designed and evaluated an active sampling device, using as analytical targets a family of pesticides purported to contribute to honeybee colony collapse disorder. Simultaneous sampling of bulk water and pore water was accomplished using a low-flow, multi-channel pump to deliver water to an array of solid-phase extraction cartridges. Analytes were separated using either liquid or gas chromatography, and analysis was performed using tandem mass spectrometry (MS/MS). Achieved recoveries of fipronil and degradates in water spiked to nominal concentrations of 0.1, 1, and 10 ng/L ranged from 77 ± 12 to 110 ± 18%. Method detection limits (MDLs) were as low as 0.040-0.8 ng/L. Extraction and quantitation of total fiproles at a wastewater-receiving wetland yielded concentrations in surface water and pore water ranging from 9.9 ± 4.6 to 18.1 ± 4.6 ng/L and 9.1 ± 3.0 to 12.6 ± 2.1 ng/L, respectively. Detected concentrations were statistically indistinguishable from those determined by conventional, more laborious techniques (p > 0.2 for the three most abundant fiproles). Aside from offering time-averaged sampling capabilities for two phases simultaneously with picogram-per-liter MDLs, the novel methodology eliminates the need for water and sediment transport via in situ solid phase extraction.

  11. High-throughput method for the determination of residues of β-lactam antibiotics in bovine milk by LC-MS/MS.

    PubMed

    Jank, Louise; Martins, Magda Targa; Arsand, Juliana Bazzan; Hoff, Rodrigo Barcellos; Barreto, Fabiano; Pizzolato, Tânia Mara

    2015-01-01

    This study describes the development and validation procedures for scope extension of a method for the determination of β-lactam antibiotic residues (ampicillin, amoxicillin, penicillin G, penicillin V, oxacillin, cloxacillin, dicloxacillin, nafcillin, ceftiofur, cefquinome, cefoperazone, cephapirine, cefalexin and cephalonium) in bovine milk. Sample preparation was performed by liquid-liquid extraction (LLE) followed by two clean-up steps, including low temperature purification (LTP) and a solid phase dispersion clean-up. Extracts were analysed using a liquid chromatography-electrospray-tandem mass spectrometry system (LC-ESI-MS/MS). Chromatographic separation was performed in a C18 column, using methanol and water (both with 0.1% of formic acid) as mobile phase. Method validation was performed according to the criteria of Commission Decision 2002/657/EC. Main validation parameters such as linearity, limit of detection, decision limit (CCα), detection capability (CCβ), accuracy, and repeatability were determined and were shown to be adequate. The method was applied to real samples (more than 250) and two milk samples had levels above maximum residues limits (MRLs) for cloxacillin - CLX and cefapirin - CFAP.

  12. [Determination of dimethyl fumarate in bakery food by d-SPE-HPLC-PDA].

    PubMed

    Yang, Jie; Luo, Mengtian; Feng, Di; Miao, Hong; Song, Shufeng; Zhao, Yunfeng

    2015-05-01

    To establish a simple and rapid pretreatment method with dispersive solid phase extraction ( d-SPE) by HPLC for determination of dimethyl fumarate in bakery foods. Dimethyl fumarate in samples was ultrasonically extracted by methanol, and cleaned up with d-SPE. Then, it was separated on C18 chromatographic column (4.6 mm x 25 mm, 5 μm) with a mixture of methanol--0.03 mol/L sodium acetate and 0.008 mol/L tetrabutyl ammonium bromide (40: 60, V/V) as mobile phase. The photodiode array detector was used in the determination under λ = 220 nm. In the linear range of 0.1 -25 μg/ml, the correlation coefficients was r > 0.999, and the average recoveries of the spiked samples were in the range of 82.8% - 107.5% with relative standard deviations (RSD) in the range of 3.30% - 7.30% (n = 6). The limit of detection ( LOD) was 0.4 mg/kg, and the limit of quantification was 1.0 mg/kg. The method is simple, rapid, sensitive and accurate, and suitable for determine dimethyl fumarate in bakery foods.

  13. Analysis of abamectin residues in avocados by high-performance liquid chromatography with fluorescence detection.

    PubMed

    Hernández-Borges, Javier; Ravelo-Pérez, Lidia M; Hernández-Suárez, Estrella M; Carnero, Aurelio; Rodríguez-Delgado, Miguel Angel

    2007-09-21

    In this work an analytical method for the determination of abamectin residues in avocados is developed using high-performance liquid chromatography (HPLC) with fluorescence (FL) detection. A pre-column derivatization with trifluoroacetic anhydride (TFAA) and N-methylimidazole (NMIM) was carried out. The mobile phase consisted of water, methanol and acetonitrile (5:47.5:47.5 v/v/v) and was pumped at a rate of 1 mL/min (isocratic elution). The fluorescence detector was set at an excitation wavelength of 365 nm and an emission wavelength of 470 nm. Homogenized avocado samples were extracted twice with acetonitrile:water 8:2 (v/v) and cleaned using C(18) solid-phase extraction (SPE) cartridges. Recovery values were in the range 87-98% with RSD values lower than 13%. The limits of detection (LODs) and quantification (LOQs) of the whole method were 0.001 and 0.003 mg/kg, respectively. These values are lower than the maximum residue limit (MRL) established by the European Union (EU) and the Spanish legislation in avocado samples.

  14. A sensitive analytical procedure for monitoring acrylamide in environmental water samples by offline SPE-UPLC/MS/MS.

    PubMed

    Togola, Anne; Coureau, Charlotte; Guezennec, Anne-Gwenaëlle; Touzé, Solène

    2015-05-01

    The presence of acrylamide in natural systems is of concern from both environmental and health points of view. We developed an accurate and robust analytical procedure (offline solid phase extraction combined with UPLC/MS/MS) with a limit of quantification (20 ng L(-1)) compatible with toxicity threshold values. The optimized (considering the nature of extraction phases, sampling volumes, and solvent of elution) solid phase extraction (SPE) was validated according to ISO Standard ISO/IEC 17025 on groundwater, surface water, and industrial process water samples. Acrylamide is highly polar, which induces a high variability during the SPE step, therefore requiring the use of C(13)-labeled acrylamide as an internal standard to guarantee the accuracy and robustness of the method (uncertainty about 25 % (k = 2) at limit of quantification level). The specificity of the method and the stability of acrylamide were studied for these environmental media, and it was shown that the method is suitable for measuring acrylamide in environmental studies.

  15. Ultra preconcentration of polycyclic aromatic hydrocarbons in smoked bacon by a combination of SPE and DLLME.

    PubMed

    Liu, Xiaofang; Zhou, Shu; Zhu, Quanfei; Ye, Yong; Chen, Huaixia

    2014-09-01

    A sample pretreatment method, solid-phase extraction combined with dispersive liquid-liquid microextraction (SPE-DLLME), was established for the sensitive determination of polycyclic aromatic hydrocarbons (PAHs) in smoked bacon samples. In the SPE-DLLME process, three PAHs including naphthalene (Naph), phenanthrene (Phen) and pyrene (Pyr) were extracted from samples and transferred into C18 SPE cartridge. The target analytes were subsequently eluted with 1.2 ml of acetonitrile-dichloromethane (5:1, v/v) mixture solution. The eluent was injected directly into the 5.0 ml ultrapure water in the subsequent DLLME procedure. The sedimented phase was concentrated under a gentle nitrogen flow to 120.0 µl. Finally, the analytes in the extraction solvent were determined by high-performance liquid chromatography with a ultra-violet detector. Some important extraction parameters affecting the performance, such as the sample solution flow rate, breakthrough volume, salt addition as well as the type and volume of the elution solvent were optimized. The developed method provided an ultra enrichment factors for PAHs ranged from 3478 to 3824. The method was applied for the selective extraction and sensitive determination of PAHs in smoked bacon samples. The limits of detection (S/N = 3) were 0.05, 0.01, 0.02 μg kg(-1) for Naph, Phen, Pyr, respectively. © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Dithizone-functionalized solid phase extraction-displacement elution-high performance liquid chromatography-inductively coupled plasma mass spectrometry for mercury speciation in water samples.

    PubMed

    Yin, Yong-guang; Chen, Ming; Peng, Jin-feng; Liu, Jing-fu; Jiang, Gui-bin

    2010-06-15

    A novel and simple solid phase extraction (SPE)-high performance liquid chromatography (HPLC)-inductively coupled plasma mass spectrometry (ICP-MS) method was developed for determination of inorganic mercury (IHg), methylmercury MeHg and ethylmercury (EtHg) in water samples in the present work. The procedure involves pre-functionalization of the commercially available C18 SPE column with dithizone, loading water sample, displacement elution of mercury species by Na(2)S(2)O(3) solution, followed by HPLC-ICP-MS determination. Characterization and optimization of operation parameters of this new SPE procedure were discussed, including eluting reagent selection, concentration of eluting reagent, volume of eluting reagent, effect of NaCl and humic acid in sample matrix. At optimized conditions, the detection limits of mercury species for 100mL water sample were about 3ngL(-1) and the average recoveries were 93.7, 83.4, and 71.7% for MeHg, IHg and EtHg, respectively, by spiking 0.2microgL(-1) mercury species into de-ion water. Stability experiment reveals that both the dithizone-functionalized SPE cartridge and the mercury species incorporated were stable in the storage procedure. These results obtained demonstrate that SPE-HPLC-ICP-MS is a simple and sensitive technique for the determination of mercury species at trace level in water samples with high reproducibility and accuracy.

  17. Metabolic profiling for the identification of Huntington biomarkers by on-line solid-phase extraction capillary electrophoresis mass spectrometry combined with advanced data analysis tools.

    PubMed

    Pont, Laura; Benavente, Fernando; Jaumot, Joaquim; Tauler, Romà; Alberch, Jordi; Ginés, Silvia; Barbosa, José; Sanz-Nebot, Victoria

    2016-03-01

    In this work, an untargeted metabolomic approach based on sensitive analysis by on-line solid-phase extraction capillary electrophoresis mass spectrometry (SPE-CE-MS) in combination with multivariate data analysis is proposed as an efficient method for the identification of biomarkers of Huntington's disease (HD) progression in plasma. For this purpose, plasma samples from wild-type (wt) and HD (R6/1) mice of different ages (8, 12, and 30 weeks), were analyzed by C18 -SPE-CE-MS in order to obtain the characteristic electrophoretic profiles of low molecular mass compounds. Then, multivariate curve resolution alternating least squares (MCR-ALS) was applied to the multiple full scan MS datasets. This strategy permitted the resolution of a large number of metabolites being characterized by their electrophoretic peaks and their corresponding mass spectra. A total number of 29 compounds were relevant to discriminate between wt and HD plasma samples, as well as to follow-up the HD progression. The intracellular signaling was found to be the most affected metabolic pathway in HD mice after 12 weeks of birth, when mice already showed motor coordination deficiencies and cognitive decline. This fact agreed with the atrophy and dysfunction of specific neurons, loss of several types of receptors, and changed expression of neurotransmitters. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Application of headspace solid-phase microextraction followed by gas chromatography coupled with mass spectrometry to determine esters of carboxylic acids and other volatile compounds in Dermestes maculatus and Dermestes ater lipids.

    PubMed

    Cerkowniak, Magdalena; Boguś, Mieczysława I; Włóka, Emilia; Stepnowski, Piotr; Gołębiowski, Marek

    2018-02-01

    A constant problem in veterinary medicine, human healthcare, agriculture, forestry and horticulture is the large number of pests, and the lack of effective methods to combat them which cause no harm to the rest of the environment. It is recommended and desired to reduce the use of chemicals and increase the use of agents based on knowledge acquired in the fields of biology, chemistry and agrochemicals. To learn the defense mechanisms of insects we should consider not only the site of their physiological ability to protect against external factors (cuticle), but also the possibility of chemical protection, formed by all compounds on the surface and in the body of insects. In this study, a procedure was developed to determine the esters of carboxylic acids in insect lipids. Headspace solid-phase microextraction was followed by gas chromatography coupled with gas spectrometry. First, the best conditions were selected for the analysis to obtain the best chromatographic separation. An RTx-5 column was used for this purpose. Polydimethylsiloxane/divinylbenzene (PDMS/DVB) and polyacrylate fibers were used to isolate acid esters. PDMS/DVB fiber achieved the best conditions for the extraction; the extraction time was 50 min, the extraction temperature was 105°C and the desorption time was 10 min at 230°C. These solid-phase microextraction conditions were used to analyze volatile compounds extracted from insects belonging to the Dermestidae family. Copyright © 2017 John Wiley & Sons, Ltd.

  19. CuMn1.8O4 protective coatings on metallic interconnects for prevention of Cr-poisoning in solid oxide fuel cells

    NASA Astrophysics Data System (ADS)

    Sun, Zhihao; Wang, Ruofan; Nikiforov, Alexey Y.; Gopalan, Srikanth; Pal, Uday B.; Basu, Soumendra N.

    2018-02-01

    Cr-poisoning of the cathodes due to the presence of metallic interconnects is detrimental to the performance of intermediate temperature solid oxide fuel cell stacks. Applying a protective coating on the interconnect is an effective solution to preventing Cr-poisoning. In this study, the application of a protective CuMn1.8O4 spinel coating is explored. Dense coatings are deposited on both metallic flat plates and meshes by electrophoretic deposition followed by thermal densification steps. The coating is found to be a mixture of Mn3O4 and cubic spinel phases at room temperature but is a pure cubic spinel phase between 750 °C and 850 °C. A reaction layer between the Cr2O3 scale at the coating/interconnect interface and CuMn1.8O4 coating is found to be a mixture of (Cu,Mn,Cr)3-xO4 cubic spinel phases with Cr-rich precipitates believed to be Cr2O3, indicating that the coating layer acts as a Cr getter. Solubility experiments show that 1 mol of the CuMn1.8O4 phase can getter at least 1.83 mol of Cr2O3 at 800 °C. Electrochemical testing of cells in the presence of coated interconnects show that the CuMn1.8O4 coating getters Cr effectively for 12 days at 800 °C, leading to no performance loss of the cell due to Cr-poisoning.

  20. Novel approach to microwave-assisted extraction and micro-solid-phase extraction from soil using graphite fibers as sorbent.

    PubMed

    Xu, Li; Lee, Hian Kee

    2008-05-30

    A single-step extraction-cleanup procedure involving microwave-assisted extraction (MAE) and micro-solid-phase extraction (micro-SPE) has been developed for the analysis of polycyclic aromatic hydrocarbons (PAHs) from soil samples. Micro-SPE is a relatively new extraction procedure that makes use of a sorbent enclosed within a sealed polypropylene membrane envelope. In the present work, for the first time, graphite fiber was used as a sorbent material for extraction. MAE-micro-SPE was used to cleanup sediment samples and to extract and preconcentrate five PAHs in sediment samples prepared as slurries with addition of water. The best extraction conditions comprised of microwave heating at 50 degrees C for a duration of 20 min, and an elution (desorption) time of 5 min using acetonitrile with sonication. Using gas chromatography (GC)-flame ionization detection (FID), the limits of detection (LODs) of the PAHs ranged between 2.2 and 3.6 ng/g. With GC-mass spectrometry (MS), LODs were between 0.0017 and 0.0057 ng/g. The linear ranges were between 0.1 and 50 or 100 microg/g for GC-FID analysis, and 1 and 500 or 1000 ng/g for GC-MS analysis. Granular activated carbon was also used for the micro-SPE device but was found to be not as efficient in the PAH extraction. The MAE-micro-SPE method was successfully used for the extraction of PAHs in river and marine sediments, demonstrating its applicability to real environmental solid matrixes.

  1. Liquid chromatographic determination of benzocaine and N-acetylbenzocaine in the edible fillet tissue from rainbow trout

    USGS Publications Warehouse

    Meinertz, J.R.; Stehly, G.R.; Hubert, T.D.; Bernardy, J.A.

    1999-01-01

    A method was developed for determining benzocaine and N-acetylbenzocaine concentrations in fillet tissue of rainbow trout. The method involves extracting the analytes with acetonitrile, removing lipids or hydrophobic compounds from the extract with hexane, and providing additional clean-up with solid-phase extraction techniques. Analyte concentrations are determined using reversed-phase high-performance liquid chromatographic techniques with an isocratic mobile phase and UV detection. The accuracy (range, 92 to 121%), precision (R.S.D., <14%), and sensitivity (method quantitation limit, <24 ng/g) for each analyte indicate the usefulness of this method for studies characterizing the depletion of benzocaine residues from fish exposed to benzocaine. Copyright (C) 1999.

  2. Single solid phase extraction method for the simultaneous analysis of polar and non-polar pesticides in urine samples by gas chromatography and ultra high pressure liquid chromatography coupled to tandem mass spectrometry.

    PubMed

    Cazorla-Reyes, Rocío; Fernández-Moreno, José Luis; Romero-González, Roberto; Frenich, Antonia Garrido; Vidal, José Luis Martínez

    2011-07-15

    A new multiresidue method has been developed and validated for the simultaneous extraction of more than two hundred pesticides, including non-polar and polar pesticides (carbamates, organochlorine, organophosphorous, pyrethroids, herbicides and insecticides) in urine at trace levels by gas and ultra high pressure liquid chromatography coupled to ion trap and triple quadrupole mass spectrometry, respectively (GC-IT-MS/MS, UHPLC-QqQ-MS/MS). Non-polar and polar pesticides were simultaneously extracted from urine samples by a simple and fast solid phase extraction (SPE) procedure using C(18) cartridges as sorbent, and dichloromethane as elution solvent. Recovery was in the range of 60-120%. Precision values expressed as relative standard deviation (RSD) were lower than 25%. Identification and confirmation of the compounds were performed by the use of retention time windows, comparison of spectra (GC-amenable compounds) or the estimation of the ion ratio (LC-amenable compounds). For GC-amenable pesticides, limits of detection (LODs) ranged from 0.001 to 0.436 μg L(-1) and limits of quantification (LOQs) from 0.003 to 1.452 μg L(-1). For LC-amenable pesticides, LODs ranged from 0.003 to 1.048 μg L(-1) and LOQs ranged from 0.011 to 3.494 μg L(-1). Finally, the optimized method was applied to the analysis of fourteen real samples of infants from agricultural population. Some pesticides such as methoxyfenozide, tebufenozide, piperonyl butoxide and propoxur were found at concentrations ranged from 1.61 to 24.4 μg L(-1), whereas methiocarb sulfoxide was detected at trace levels in two samples. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. [Method of component assay of alpha-glucosyltransferase-treated stevia (enzymatically modified stevia) products using enzymatic hydrolysis].

    PubMed

    Hirata, Keiko; Shimamura, Yasuhiro; Suzuki, Keiko; Sadamasu, Yuki; Ito, Koichi

    2005-12-01

    We have developed an analytical method for components of alpha-glucosyltransferase-treated stevia, a food additive product. Suitable conditions to separate additional sugar from alpha-glucosyltransferase-treated stevia by using glucoamylase were found (55 degrees C for 3 hr with 250 U of glucoamylase in 10 mL of reaction solution). By solid-phase extraction using a C18 cartridge column, polysaccharides were excluded from the sample, and the glycosides and sugar obtained after hydrolysis with glucoamylase were separated on another C18 cartridge column. The glycosides and sugar contents were determined by HPLC. By this method, additional sugar was detected in all of three product samples tested and the sugar was glucose. The contents of glucose and total glycosides (minus unreacted glycoside) were 25-42% and 35.7-52.5%, respectively. In alpha-glucosyltransferase-treated stevia, the sum of total glycosides and glucose amounted to 77.5-80.4% of the total and their recoveries from samples from which polysaccharide had been excluded by C18 cartridge column processing were over 85%. The contents of alpha-glucosyltransferase-treated stevia obtained by multiplying the sugar content by the coefficient (0.9) for hydrolysis and converting on dry weight basis were all over 80.0% and met the standard set by the Japan Food Additives Association.

  4. SEQUENTIAL EXTRACTIONS FOR PARTITIONING OF ARSENIC ON HYDROUS IRON OXIDES AND IRON SULFIDES

    EPA Science Inventory

    The objective of this study was to use model solids to test solutions designed to extract arsenic from relatively labile solid phase fractions. The use of sequential extractions provides analytical constraints on the identification of mineral phases that control arsenic mobility...

  5. Interaction of the cesium cation with calix[4]arene-bis(t-octylbenzo-18-crown-6): Extraction and DFT study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Makrlik, Emanuel; Toman, Petr; Vanura, Petr

    2013-01-01

    From extraction experiments and c-activity measurements, the extraction constant corresponding to the equilibrium Cs+ (aq) + I (aq) + 1 (org),1Cs+ (org) + I (org) taking place in the two-phase water-phenyltrifluoromethyl sulfone (abbrev. FS 13) system (1 = calix[4]arene-bis(t-octylbenzo-18-crown-6); aq = aqueous phase, org = FS 13 phase) was evaluated as logKex (1Cs+, I) = 2.1 0.1. Further, the stability constant of the 1Cs+ complex in FS 13 saturated with water was calculated for a temperature of 25 C: log borg (1Cs+) = 9.9 0.1. Finally, by using quantum mechanical DFT calculations, the most probable structure of the cationic complexmore » species 1Cs+ was derived. In the resulting 1Cs+ complex, the central cation Cs+ is bound by eight bond interactions to six oxygen atoms of the respective 18-crown-6 moiety and to two carbons of the corresponding two benzene rings of the parent ligand 1 via cation p interaction.« less

  6. Solid-phase micro-extraction procedure for the determination of 1,3-dichloro-2-propanol in water by on-fibre derivatisation with bis(trimethylsilyl)trifluoroacetamide.

    PubMed

    Carro, Antonia María; González, Paula; Fajar, Noelia; Lorenzo, Rosa Antonia; Cela, Rafael

    2009-06-01

    The headspace solid-phase micro-extraction technique with on-fibre derivatisation followed by gas chromatography-tandem mass spectrometry has been evaluated for the analysis of 1,3-dichloro-2-propanol in water. An asymmetric factorial design has been performed to study the influence of five experimental factors: extraction time and temperature, derivatisation time and temperature and pH. The best extraction performance is achieved in the headspace mode, with 5 mL stirred water samples (pH 4) containing 1.3 g of NaCl, equilibrated for 30 min at 25 degrees C, using divinylbenzene-carboxen-polydimethylsiloxane as the fibre coating. On-fibre derivatisation has been used for the first time with 50 microL of bis(trimethylsilyl)trifluoroacetamide at 25 degrees C during 15 min, leading to effective yields. The proposed method provides high sensitivity, good linearity and repeatability (relative standard deviation of 5.1% for 10 ng mL(-1) and n = 5). The limits of detection and quantification were 0.4 and 1.4 ng mL(-1), respectively. Analytical recoveries obtained for different water samples were approx. 100%.

  7. Hypercrosslinked particles for the extraction of sweeteners using dispersive solid-phase extraction from environmental samples.

    PubMed

    Lakade, Sameer S; Zhou, Qing; Li, Aimin; Borrull, Francesc; Fontanals, Núria; Marcé, Rosa M

    2018-04-01

    This work presents a new extraction material, namely, Q-100, based on hypercrosslinked magnetic particles, which was tested in dispersive solid-phase extraction for a group of sweeteners from environmental samples. The hypercrosslinked Q-100 magnetic particles had the advantage of suitable pore size distribution and high surface area, and showed good retention behavior toward sweeteners. Different dispersive solid-phase extraction parameters such as amount of magnetic particles or extraction time were optimized. Under optimum conditions, Q-100 showed suitable apparent recovery, ranging in the case of river water sample from 21 to 88% for all the sweeteners, except for alitame (12%). The validated method based on dispersive solid-phase extraction using Q-100 followed by liquid chromatography with tandem mass spectrometry provided good linearity and limits of quantification between 0.01 and 0.1 μg/L. The method was applied to analyze samples from river water and effluent wastewater, and four sweeteners (acesulfame, saccharin, cyclamate, and sucralose) were found in both types of sample. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Experimental and computational studies on molecularly imprinted solid-phase extraction for gonyautoxins 2,3 from dinoflagellate Alexandrium minutum.

    PubMed

    Lian, Ziru; Li, Hai-Bei; Wang, Jiangtao

    2016-08-01

    An innovative and effective extraction procedure based on molecularly imprinted solid-phase extraction (MISPE) was developed for the isolation of gonyautoxins 2,3 (GTX2,3) from Alexandrium minutum sample. Molecularly imprinted polymer microspheres were prepared by suspension polymerization and and were employed as sorbents for the solid-phase extraction of GTX2,3. An off-line MISPE protocol was optimized. Subsequently, the extract samples from A. minutum were analyzed. The results showed that the interference matrices in the extract were obviously cleaned up by MISPE procedures. This outcome enabled the direct extraction of GTX2,3 in A. minutum samples with extraction efficiency as high as 83 %, rather significantly, without any need for a cleanup step prior to the extraction. Furthermore, computational approach also provided direct evidences of the high selective isolation of GTX2,3 from the microalgal extracts.

  9. Ultrasensitive quantification of endogenous brassinosteroids in milligram fresh plant with a quaternary ammonium derivatization reagent by pipette-tip solid-phase extraction coupled with ultra-high-performance liquid chromatography tandem mass spectrometry.

    PubMed

    Deng, Ting; Wu, Dapeng; Duan, Chunfeng; Guan, Yafeng

    2016-07-22

    Determination of endogenous brassinosteroids (BRs) in limited sample amount is vital to elucidating their tissue- and even local tissue-specific signaling pathway and physiological effects on plant growth and development. In this work, an ultra-sensitive quantification method was established for endogenous BRs in milligram fresh plant by using pipette-tip solid-phase extraction coupled with ultra-performance liquid chromatography tandem mass spectrometry (PT-SPE-UPLC-MS/MS), in which a quaternary ammonium phenyl boronic acid, 4-borono-N,N,N-trimethylbenzenaminium iodide (BTBA) was first developed for chemical derivatization of BRs. Due to the cationic quaternary ammonium group of BTBA, the ionization efficiencies of the BRs chelates with BTBA (BTBA-BRs) were enhanced by 1190-448785 times, which is the highest response enhancement factor among all derivatization reagents reported for BRs. In addition, PT-SPE packed with C18 sorbent was first used for purifying BRs from plant extracts, so the required sample amount was minimized, and recoveries higher than 91% were achieved. Under the optimized conditions, the minimal detectable amounts (MDA) of five target BRs were in the range of 27-94 amol, and the correlation coefficients (R(2)) were >0.9985 over four orders of magnitude. The relative recoveries of 75.8-104.9% were obtained with the intra- and inter-day relative standard deviations (RSDs) less than 18.7% and 19.6%, respectively. Finally, three BRs were successfully quantified in only 5mg fresh rice plant samples, and 24-epiBL can even be detected in only 0.5mg FW rice leaf segments. It is the first time that the BRs content in sub-milligram fresh plant sample has been quantified. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Microwave assisted solid phase extraction for separation preconcentration sulfamethoxazole in wastewater using tyre based activated carbon as solid phase material prior to spectrophotometric determination

    NASA Astrophysics Data System (ADS)

    Mogolodi Dimpe, K.; Mpupa, Anele; Nomngongo, Philiswa N.

    2018-01-01

    This work was chiefly encouraged by the continuous consumption of antibiotics which eventually pose harmful effects on animals and human beings when present in water systems. In this study, the activated carbon (AC) was used as a solid phase material for the removal of sulfamethoxazole (SMX) in wastewater samples. The microwave assisted solid phase extraction (MASPE) as a sample extraction method was employed to better extract SMX in water samples and finally the analysis of SMX was done by the UV-Vis spectrophotometer. The microwave assisted solid phase extraction method was optimized using a two-level fractional factorial design by evaluating parameters such as pH, mass of adsorbent (MA), extraction time (ET), eluent ratio (ER) and microwave power (MP). Under optimized conditions, the limit of detection (LOD) and limit of quantification (LOQ) were 0.5 μg L- 1 and 1.7 μg L- 1, respectively, and intraday and interday precision expressed in terms of relative standard deviation were > 6%.The maximum adsorption capacity was 138 mg g- 1 for SMX and the adsorbent could be reused eight times. Lastly, the MASPE method was applied for the removal of SMX in wastewater samples collected from a domestic wastewater treatment plant (WWTP) and river water.

  11. Application of solid phase microextraction followed by liquid chromatography-mass spectrometry in the determination of antibiotic drugs and their metabolites in human whole blood and tissue samples.

    PubMed

    Szultka-Mlynska, Malgorzata; Pomastowski, Pawel; Buszewski, Boguslaw

    2018-06-01

    A sensitive, rapid and specific analytical method using high performance liquid chromatography coupled with mass spectrometry (HPLC-QqQ-MS) was developed to determine selected antibiotic drugs and their metabolites (amoxicillin, cefotaxime, ciprofloxacin, clindamycin and metronidazole; amoxycilloic acid, 4-hydroxyphenyl glycyl amoxicillin, desacetyl cefotaxime, 3-desacetyl cefotaxime lactone, ciprofloxacin N-oxide, N-demethylclindamycin, clindamycin sulfoxide, and hydroxy metronidazole) in human whole blood and vascularized tissue after single oral administration. The samples were prepared by solid phase microextraction with C18 fibers (SPME C18 ) and determined on a GRACE analytical C18 column, Vision HT (50 × 2 mm, 1.5 μm) at the flow rate of 0.4 mL min -1 using water and acetonitrile (containing 0.1% formic acid) as the mobile phase. The proposed method was successfully applied in a pharmacokinetic study of the selected antibiotic drugs and their metabolites in real human samples. Additionally, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI/TOF-MS) was used for identification and qualification analysis of the target compounds. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Determination of bone and tissue concentrations of teicoplanin mixed with hydroxyapatite cement to repair cortical defects.

    PubMed

    Eggenreich, K; Zeipper, U; Schwendenwein, E; Hadju, S; Kaltenecker, G; Laslo, I; Lang, S; Roschger, P; Vecsei, V; Wintersteiger, R

    2002-01-01

    A highly specific and sensitive isocratic reversed-phase high performance liquid chromatography (HPLC) method for the determination of the major component of teicoplanin in tissue is reported. Comparing fluorescamine and o-phthalaldehyde (OPA) as derivatizing agents, the derivative formed with the latter exhibits superior fluorescence intensity allowing detection of femtomole quantities. Pretreatment for tissue samples is by solid-phase extraction which uses Bakerbond PolarP C(18) cartridges and gives effective clean up from endogenous by-products. Linearity was given from 0.6 to 100 ng per injection. The coefficient of variation did not exceed 5.8% for both interday and intraday assays. It was found that when bone defects are repaired with a hydroxyapatite-teicoplanin mixture, the antibiotic does not degrade, even when it is in the cement for several months. The stability of teicoplanin in bone cement was determined fluorodensitometrically.

  13. Assessing the Selectivity of Extractant Solutions for Recovering Labile Arsenic Associated with Iron (Hydr)oxides and Sulfides in Sediments

    EPA Science Inventory

    Sequential extractions can provide analytical constraints on the identification of mineral phases that control arsenic speciation in sediments. Model solids were used in this study to evaluate different solutions designed to extract arsenic from relatively labile solid phases. ...

  14. Isolation and recovery of selected polybrominated diphenyl ethers from human serum and sheep serum: coupling reversed-phase solid-phase disk extraction and liquid-liquid extraction techniques with a capillary gas chromatographic electron capture negative ion mass spectrometric determinative technique.

    PubMed

    Loconto, Paul R; Isenga, David; O'Keefe, Michael; Knottnerus, Mark

    2008-01-01

    Polybrominated diphenyl ethers (PBDEs) are isolated and recovered with acceptable percent recoveries from human serum via liquid-liquid extraction and column chromatographic cleanup and fractionation with quantitation using capillary gas chromatography-mass spectrometry with electron capture negative ion and selected ion monitoring. PBDEs are found in unspiked serum. An alternative sample preparation approach is developed using sheep serum that utilizes a formic acid pre-treatment followed by reversed-phase solid-phase disk extraction and normal-phase solid-phase cleanup using acidified silica gel that yields>50% recoveries. When these percent recoveries are combined with a minimized phase ratio for human serum and very low instrument detection limits, method detection limits below 500 parts-per-trillion are realized.

  15. Application of Solid Phase Extraction on Multiwalled Carbon Nanotubes of Some Heavy Metal Ions to Analysis of Skin Whitening Cosmetics Using ICP-AES

    PubMed Central

    ALqadami, Ayoub A.; Abdalla, Mohammad Abulhassan; ALOthman, Zeid A.; Omer, Kamal

    2013-01-01

    A novel and highly sensitive method for the determination of some heavy metals in skin whitening cosmetics creams using multiwalled carbon nanotubes MWCNTs as solid phase extraction sorbent for the preconcentration of these heavy metals prior to their determination by inductively coupled plasma atomic emission spectrometry is described. Different practical parameters have been thoroughly investigated and the optimum experimental conditions were employed. The developed method was then applied for the determination of arsenic, bismuth, cadmium, mercury, lead and titanium in samples of skin whitening cosmetics. The detection limits under these conditions for As, Bi, Cd, Pb, Hg and Ti were 2.4, 4.08, 0.3, 2.1, 1.8, and 1.8 ng·mL−1, respectively. The relative standard deviations (RSDs) were found to be less than 2.0%. For validation, a certified reference material of NIST SRM 1570a spinach leaves was analyzed and the determined values were in good agreement with the certified values. The recoveries for spiked samples were found to be in the range of 89.6–104.4%. PMID:23343988

  16. Preparation of l-phenylalanine-imprinted solid-phase extraction sorbent by Pickering emulsion polymerization and the selective enrichment of l-phenylalanine from human urine.

    PubMed

    Li, Ji; Hu, Xiaoling; Guan, Ping; Zhang, Xiaoyan; Qian, Liwei; Zhang, Nan; Du, Chunbao; Song, Renyuan

    2016-05-01

    A novel l-phenylalanine molecularly imprinted solid-phase extraction sorbent was synthesized by the combination of Pickering emulsion polymerization and ion-pair dummy template imprinting. Compared to other polymerization methods, the molecularly imprinted polymers thus prepared exhibit a high specific surface, large pore diameter, and appropriate particle size. The key parameters for solid-phase extraction were optimized, and the result indicated that the molecularly imprinted polymer thus prepared exhibits a good recovery of 98.9% for l-phenylalanine. Under the optimized conditions of the procedure, an analytical method for l-phenylalanine was well established. By comparing the performance of the molecularly imprinted polymer and a commercial reverse-phase silica gel, the obtained molecularly imprinted polymer as an solid-phase extraction sorbent is more suitable, exhibiting high precision (relative standard deviation 3.2%, n = 4) and a low limit of detection (60.0 ± 1.9 nmol·L(-1) ) for the isolation of l-phenylalanine. Based on these results, the combination of the Pickering emulsion polymerization and ion-pair dummy template imprinting is effective for preparing selective solid-phase extraction sorbents for the separation of amino acids and organic acids from complex biological samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Rapid and automated analysis of aflatoxin M1 in milk and dairy products by online solid phase extraction coupled to ultra-high-pressure-liquid-chromatography tandem mass spectrometry.

    PubMed

    Campone, Luca; Piccinelli, Anna Lisa; Celano, Rita; Pagano, Imma; Russo, Mariateresa; Rastrelli, Luca

    2016-01-08

    This study reports a fast and automated analytical procedure for the analysis of aflatoxin M1 (AFM1) in milk and dairy products. The method is based on the simultaneous protein precipitation and AFM1 extraction, by salt-induced liquid-liquid extraction (SI-LLE), followed by an online solid-phase extraction (online SPE) coupled to ultra-high-pressure-liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) analysis to the automatic pre-concentration, clean up and sensitive and selective determination of AFM1. The main parameters affecting the extraction efficiency and accuracy of the analytical method were studied in detail. In the optimal conditions, acetonitrile and NaCl were used as extraction/denaturant solvent and salting-out agent in SI-LLE, respectively. After centrifugation, the organic phase (acetonitrile) was diluted with water (1:9 v/v) and purified (1mL) by online C18 cartridge coupled with an UHPLC column. Finally, selected reaction monitoring (SRM) acquisition mode was applied to the detection of AFM1. Validation studies were carried out on different dairy products (whole and skimmed cow milk, yogurt, goat milk, and powder infant formula), providing method quantification limits about 25 times lower than AFM1 maximum levels permitted by EU regulation 1881/2006 in milk and dairy products for direct human consumption. Recoveries (86-102%) and repeatability (RSD<3, n=6) meet the performance criteria required by EU regulation N. 401/2006 for the determination of the levels of mycotoxins in foodstuffs. Moreover, no matrix effects were observed in the different milk and dairy products studied. The proposed method improves the performance of AFM1 analysis in milk samples as AFM1 determination is performed with a degree of accuracy higher than the conventional methods. Other advantages are the reduction of sample preparation procedure, time and cost of the analysis, enabling high sample throughput that meet the current concerns of food safety and the public health protection. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Direct analysis of 18 flavonol glycosides, aglycones and terpene trilactones in Ginkgo biloba tablets by matrix solid phase dispersion coupled with ultra-high performance liquid chromatography tandem triple quadrupole mass spectrometry.

    PubMed

    Liu, Xin-Guang; Yang, Hua; Cheng, Xiao-Lan; Liu, Lei; Qin, Yong; Wang, Qi; Qi, Lian-Wen; Li, Ping

    2014-08-01

    Analysis and quality control of Ginkgo biloba have been comprehensively studied. However, little attention has been devoted to the simultaneous extraction and analysis of flavonols and terpene trilactones, especially for direct quantification of flavonol glycosides. This work described a rapid strategy for one-step extraction and quantification of the components. A matrix solid phase dispersion (MSPD) method was designed for the extraction of ginkgo ingredients and compared with the heat-reflux and ultrasonic extraction methods. An ultra-high performance liquid chromatography (UHPLC)-tandem-triple-quadrupole-mass spectrometry (QQQ-MS) method was developed for detection of the 18 components, including 10 original flavonol glycosides, 3 aglycones, and 5 lactones. Subsequently, the proposed strategy was used for the analysis of 12 G. biloba tablets. Results showed that MSPD produced comparable extraction efficiency but consumed less time and required lower solvent volumes compared with conventional methods. Without hydrolysis, the concentration detected was much closer to the original in the sample. The total flavonol glycoside contents in ginkgo tablets ranged from 3.59 to 125.21μgmg(-1), and the terpene trilactone varied from 3.45 to 57.8μgmg(-1) among different manufacturers. In conclusion, the proposed MSPD and UHPLC-QQQ-MS is rapid and sensitive in providing comprehensive profile of chemical constituents especially the genuine flavonol glycosides for improved quality control of ginkgo products. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Determination of nitrogen-15 isotope fractionation in tropine: evaluation of extraction protocols for isotope ratio measurement by isotope ratio mass spectrometry.

    PubMed

    Molinié, Roland; Kwiecień, Renata A; Silvestre, Virginie; Robins, Richard J

    2009-12-01

    N-Demethylation of tropine is an important step in the degradation of this compound and related metabolites. With the purpose of understanding the reaction mechanism(s) involved, it is desirable to measure the 15N kinetic isotope effects (KIEs), which can be accessed through the 15N isotope shift (Deltadelta15N) during the reaction. To measure the isotope fractionation in 15N during tropine degradation necessitates the extraction of the residual substrate from dilute aqueous solution without introducing artefactual isotope fractionation. Three protocols have been compared for the extraction and measurement of the 15N/14N ratio of tropine from aqueous medium, involving liquid-liquid phase partitioning or silica-C18 solid-phase extraction. Quantification was by gas chromatography (GC) on the recovered organic phase and delta15N values were obtained by isotope ratio measurement mass spectrometry (irm-MS). Although all the protocols used can provide satisfactory data and both irm-EA-MS and irm-GC-MS can be used to obtain the delta15N values, the most convenient method is liquid-liquid extraction from a reduced aqueous volume combined with irm-GC-MS. The protocols are applied to the measurement of 15N isotope shifts during growth of a Pseudomonas strain that uses tropane alkaloids as sole source of carbon and nitrogen. The accuracy of the determination of the 15N/14N ratio is sufficient to be used for the determination of 15N-KIEs. Copyright 2009 John Wiley & Sons, Ltd.

  20. A comparison study on a sulfonated graphene-polyaniline nanocomposite coated fiber for analysis of nicotine in solid samples through the traditional and vacuum-assisted HS-SPME.

    PubMed

    Ghiasvand, Alireza; Koonani, Samira; Yazdankhah, Fatemeh; Farhadi, Saeid

    2018-02-05

    A simple, rapid, and reliable headspace solid-phase microextraction (HS-SPME) procedure, reinforced by applying vacuum in the extraction vial, was developed. It was applied for the extraction of nicotine in solid samples prior to determination by gas chromatography-flame ionization detection (GC-FID). First, the surface of a narrow stainless steel wire was made porous and adhesive by platinization to obtain a durable, higher surface area, and resistant fiber. Then, a thin film of sulfonated graphene/polyaniline (Sulf-G/PANI) nanocomposite was synthesized and simultaneously coated on the platinized fiber using the electrophoretic deposition (EPD) method. It was demonstrated that the extraction efficiency remarkably increased by applying the reduced-pressure condition in the extraction vial. To evaluate the conventional HS-SPME and vacuum-assisted HS-SPME (VA-HS-SPME) platforms, all experimental parameters affecting the extraction efficiency including desorption time and temperature, extraction time and temperature and moisture content of sample matrix were optimized. The highest extraction efficiency was obtained at 60°C, 10min (extraction temperature and time) and 280°C, 2min (desorption condition), for VA-HS-SPME strategy, while for conventional HS-SPME the extraction and desorption conditions found to be 100°C, 30min and 280°C, 2min, respectively. The Sulf-G/PANI coated fiber showed high thermal stability, good chemical/mechanical resistance, and long lifetime. For analysis of nicotine in solid samples using VA-HS-SPME-GC-FID, linear dynamic range (LDR) was 0.01-30μgg -1 (R 2 =0.996), the relative standard deviation (RSD%, n=6), for analyses of 1μgg -1 nicotine was calculated 3.4% and limit of detection (LOD) found to be 0.002μgg -1 . The VA-HS-SPME-GC-FID strategy was successfully carried out for quantitation of nicotine in hair and tobacco real samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Optimization and application of octadecyl-modified monolithic silica for solid-phase extraction of drugs in whole blood samples.

    PubMed

    Namera, Akira; Saito, Takeshi; Ota, Shigenori; Miyazaki, Shota; Oikawa, Hiroshi; Murata, Kazuhiro; Nagao, Masataka

    2017-09-29

    Monolithic silica in MonoSpin for solid-phase extraction of drugs from whole blood samples was developed to facilitate high-throughput analysis. Monolithic silica of various pore sizes and octadecyl contents were synthesized, and their effects on recovery rates were evaluated. The silica monolith M18-200 (20μm through-pore size, 10.4nm mesopore size, and 17.3% carbon content) achieved the best recovery of the target analytes in whole blood samples. The extraction proceeded with centrifugal force at 1000rpm for 2min, and the eluate was directly injected into the liquid chromatography-mass spectrometry system without any tedious steps such as evaporation of extraction solvents. Under the optimized condition, low detection limits of 0.5-2.0ngmL -1 and calibration ranges up to 1000ngmL -1 were obtained. The recoveries of the target drugs in the whole blood were 76-108% with relative standard deviation of less than 14.3%. These results indicate that the developed method based on monolithic silica is convenient, highly efficient, and applicable for detecting drugs in whole blood samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Poly(ionic liquids)-coated stainless-steel wires packed into a polyether ether ketone tube for in-tube solid-phase microextraction.

    PubMed

    Feng, Juanjuan; Wang, Xiuqin; Tian, Yu; Luo, Chuannan; Sun, Min

    2017-12-01

    An in-tube solid-phase microextraction device was developed by packing poly(ionic liquids)-coated stainless-steel wires into a polyether ether ketone tube. An anion-exchange process was performed to enhance the extraction performance. Surface properties of poly(ionic liquids)-coated stainless-steel wires were characterized by scanning electron microscopy and energy dispersive X-ray spectrometry. The extraction device was connected to high-performance liquid chromatography equipment to build an online enrichment and analysis system. Ten polycyclic aromatic hydrocarbons were used as model analytes, and important conditions including extraction time and desorption time were optimized. The enrichment factors from 268 to 2497, linear range of 0.03-20 μg/L, detection limits of 0.010-0.020 μg/L, extraction and preparation repeatability with relative standard deviation less than 1.8 and 19%, respectively were given by the established online analysis method. It has been used to detect polycyclic aromatic hydrocarbons in environmental samples, with the relative recovery (5, 10 μg/L) in the range of 85.1-118.9%. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. [Determination of 3-monochloropropane-1,2-diol in grease food by solid phase extraction-derivatization-gas chromatography-mass spectrometry].

    PubMed

    Xiang, Xiaoling; Wang, Liyuan; Shen, Xianghong; Li, Chunsong; Shen, Jianfu; Wu, Pinggu

    2017-09-01

    To establish the method of determination of 3-monochloropropane-1,2-diol( 3-MCPD) in grease food by gas chromatography-mass spectrometry( GC-MS). 3-MCPD in grease food represented by bean paste was extracted by ultrasound,purified by alkaline earth solid phase extraction column,derivatived using phenylboronic acid( PBA) and detected by GC-MS. The linearity of 3-MCPD ranged from 1-100 ng/mL,with correlation coefficient at 0. 9993.The limits of quantitation( LOQ) in soy sauce,bean paste,pepper oil were 0. 6,0. 5 and7. 0 μg/kg and limits of detection( LOD) were 1. 9,1. 6 and 18. 8 μg/kg,respectively.Average recovery rate and relative standard deviation was 78. 3%-106. 7% and 1. 9%-11. 6%( n = 6), when 3-MCPD was added in grease food at 2. 5-1000 μg/kg. The method has good purification effect and the detection sensitivity and accuracy,and can be used for the determination of 3-MCPD in grease food.

  4. Ultrasonic-assisted extraction combined with sample preparation and analysis using LC-ESI-MS/MS allowed the identification of 24 new phenolic compounds in pecan nut shell [Carya illinoinensis (Wangenh) C. Koch] extracts.

    PubMed

    Hilbig, Josiane; Alves, Victor Rodrigues; Müller, Carmen Maria Olivera; Micke, Gustavo Amadeu; Vitali, Luciano; Pedrosa, Rozangela Curi; Block, Jane Mara

    2018-04-01

    Ultrasonic-assisted extraction combined with statistical tools (factorial design, response surface methodology and kinetics) were used to evaluate the effects of the experimental conditions of temperature, solid-to-solvent ratio, ethanol concentration and time for the extraction of the total phenolic content from pecan nut shells. The optimal conditions for the aqueous and hydroalcoholic extract (with 20% v/v of ethanol) were 60 and 80 °C; solid to solvent ratio of 30 mL·g -1 (for both) and extraction time of 35 and 25 min, respectively. Using these optimize extraction conditions, 426 and 582 mg GAE·g -1 of phenolic compounds, from the aqueous and hydroalcoholic phases respectively, were obtained. In addition, the analysis of the phenolic compounds using the LC-ESI-MS/MS system allowed the identification of 29 phenolic compounds, 24 of which had not been reported in literature for this raw material yet. Copyright © 2018. Published by Elsevier Ltd.

  5. Solid-phase extraction of polar pesticides from environmental water samples on graphitized carbon and Empore-activated carbon disks and on-line coupling to octadecyl-bonded silica analytical columns.

    PubMed

    Slobodník, J; Oztezkizan, O; Lingeman, H; Brinkman, U A

    1996-10-25

    The suitability of Empore-activated carbon disks (EACD), Envi-Carb graphitized carbon black (GCB) and CPP-50 graphitized carbon for the trace enrichment of polar pesticides from water samples was studied by means of off-line and on-line solid-phase extraction (SPE). In the off-line procedure, 0.5-2 l samples spiked with a test mixture of oxamyl, methomyl and aldicarb sulfoxide were enriched on EnviCarb SPE cartridges or 47 mm diameter EACD and eluted with dichloromethane-methanol. After evaporation, a sample was injected onto a C18-bonded silica column and analysed by liquid chromatography with ultraviolet (LC-UV) detection. EACD performed better than EnviCarb cartridges in terms of breakthrough volumes (> 2 l for all test analytes), reproducibility (R.S.D. of recoveries, 4-8%, n = 3) and sampling speed (100 ml/min); detection limits in drinking water were 0.05-0.16 microgram/l. In the on-line experiments, 4.6 mm diameter pieces cut from original EACD and stacked onto each other in a 9 mm long precolumn, and EnviCarb and CPP-50 packed in 10 x 2.0 mm I.D. precolumn, were tested, and 50-200 ml spiked water samples were preconcentrated. Because of the peak broadening caused by the strong sorption of the analytes on carbon, the carbon-packed precolumns were eluted by a separate stream of 0.1 ml/min acetonitrile which was mixed with the gradient LC eluent in front of the C18 analytical column. The final on-line procedure was also applied for the less polar propoxur, carbaryl and methiocarb. EnviCarb could not be used due to its poor pressure resistance. CPP-50 provided less peak broadening than EACD: peak widths were 0.1-0.3 min and R.S.D. of peak heights 4-14% (n = 3). In terms of analyte trapping efficiency on-line SPE-LC-UV with a CPP-50 precolumn also showed better performance than when Bondesil C18/OH or polymeric PLRP-S was used, but chromatographic resolution was similar. With the CPP-50-based system, detection limits of the test compounds were 0.05-1 microgram/l in surface water.

  6. Investigation of fragrance stability used in the formulation of cosmetic and hygienic products using headspace solid-phase microextraction by nanostructured materials followed by gas chromatography with mass spectrometry.

    PubMed

    Masoum, Saeed; Gholami, Ali; Ghaheri, Salehe; Bouveresse, Delphine Jouan-Rimbaud; Cordella, Christophe B Y; Rutledge, Douglas N

    2016-07-01

    A new composite coating of polypyrrole and sodium lauryl ether sulfate was electrochemically prepared on a stainless-steel wire using cyclic voltammetry. The application and performance of the fiber was evaluated for the headspace solid-phase microextraction of a fragrance in aqueous bleach samples followed by gas chromatography combined with mass spectrometry to assess the fragrance stability in this kind of household cleaning product. To obtain a stable and efficient composite coating, parameters related to the coating process such as scan rate and numbers of cycles were optimized using a central composite design. In addition, the effects of various parameters on the extraction efficiency of the headspace solid-phase microextraction process such as extraction temperature and time, ionic strength, sample volume, and stirring rate were investigated by experimental design methods using Plackett-Burman and Doehlert designs. The optimum values of 53°C and 28 min for sample temperature and time, respectively, were found through response surface methodology. Results show that the combination of polypyrrole and sodium lauryl ether sulfate in a composite form presents desirable opportunities to produce new materials to study fragrance stability by headspace solid-phase microextraction. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Simultaneous determination of phenolic compounds in Equisetum palustre L. by ultra high performance liquid chromatography with tandem mass spectrometry combined with matrix solid-phase dispersion extraction.

    PubMed

    Wei, Zuofu; Pan, Youzhi; Li, Lu; Huang, Yuyang; Qi, Xiaolin; Luo, Meng; Zu, Yuangang; Fu, Yujie

    2014-11-01

    A method based on matrix solid-phase dispersion extraction followed by ultra high performance liquid chromatography with tandem mass spectrometry is presented for the extraction and determination of phenolic compounds in Equisetum palustre. This method combines the high efficiency of matrix solid-phase dispersion extraction and the rapidity, sensitivity, and accuracy of ultra high performance liquid chromatography with tandem mass spectrometry. The influential parameters of the matrix solid-phase dispersion extraction were investigated and optimized. The optimized conditions were as follows: silica gel was selected as dispersing sorbent, the ratio of silica gel to sample was selected to be 2:1 (400/200 mg), and 8 mL of 80% methanol was used as elution solvent. Furthermore, a fast and sensitive ultra high performance liquid chromatography with tandem mass spectrometry method was developed for the determination of nine phenolic compounds in E. palustre. This method was carried out within <6 min, and exhibited satisfactory linearity, precision, and recovery. Compared with ultrasound-assisted extraction, the proposed matrix solid-phase dispersion procedure possessed higher extraction efficiency, and was more convenient and time saving with reduced requirements on sample and solvent amounts. All these results suggest that the developed method represents an excellent alternative for the extraction and determination of active components in plant matrices. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Silica Modified with Polyaniline as a Potential Sorbent for Matrix Solid Phase Dispersion (MSPD) and Dispersive Solid Phase Extraction (d-SPE) of Plant Samples

    PubMed Central

    Sowa, Ireneusz; Wójciak-Kosior, Magdalena; Strzemski, Maciej; Sawicki, Jan; Staniak, Michał; Dresler, Sławomir; Szwerc, Wojciech; Mołdoch, Jarosław; Latalski, Michał

    2018-01-01

    Polyaniline (PANI) is one of the best known conductive polymers with multiple applications. Recently, it was also used in separation techniques, mostly as a component of composites for solid-phase microextraction (SPME). In the present paper, sorbent obtained by in situ polymerization of aniline directly on silica gel particles (Si-PANI) was used for dispersive solid phase extraction (d-SPE) and matrix solid–phase extraction (MSPD). The efficiency of both techniques was evaluated with the use of high performance liquid chromatography with diode array detection (HPLC-DAD) quantitative analysis. The quality of the sorbent was verified by Raman spectroscopy and microscopy combined with automated procedure using computer image analysis. For extraction experiments, triterpenes were chosen as model compounds. The optimal conditions were as follows: protonated Si-PANI impregnated with water, 160/1 sorbent/analyte ratio, 3 min of extraction time, 4 min of desorption time and methanolic solution of ammonia for elution of analytes. The proposed procedure was successfully used for pretreatment of plant samples. PMID:29565297

  9. One-pot synthesis of ethylenediamine-connected graphene/carbon nanotube composite material for isolation of clenbuterol from pork.

    PubMed

    Yuan, Yanan; Jiao, Xiaoyan; Han, Yehong; Bai, Ligai; Liu, Haiyan; Qiao, Fengxia; Yan, Hongyuan

    2017-09-01

    A fluffy porous ethylenediamine-connected graphene/carbon nanotube composite (EGC), prepared by a simple and time-saving one-pot synthesis, was successfully applied as an adsorbent in pipette-tip solid-phase extraction (PT-SPE) for the rapid extraction and determination of clenbuterol (CLB) from pork. In the one-pot synthesis, carbon nanotubes were inserted into graphene sheets and then connected with ethylenediamine through chemical modification to form a three-dimensional framework structure to prevent agglomeration of the graphene sheets. Under the optimum conditions for extraction and determination, good linearity was achieved for CLB in the range of 15.0-1000.0ngg -1 (r=0.9998) and the recoveries at three spiked levels were in the range of 92.2-96.2% with relative standard deviation ≤9.2% (n=3). In comparison with other adsorbents, including silica, NH 2 , C 18 , and Al 2 O 3 , EGC showed higher extraction and purification efficiency for CLB from pork samples. This analytical method combines excellent adsorption performance of EGC and high extraction efficiency of PT-SPE. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Quantitative Determination of Four Azo Dyes in Rat Plasma with Solid-Phase Extraction and UFLC-MS-MS Analysis: Application to a Pharmacokinetic Study.

    PubMed

    Zhu, Hao; Huang, Changshun; Chen, Yijun; Lu, Zihui; Zhou, Haidong; Chen, Chunru; Wu, Jin; Chen, Xiaohong; Jin, Micong

    2016-06-05

    A rapid and sensitive ultra-fast liquid chromatography tandem mass spectrometry method, followed by simple protein precipitation and solid-phase extraction, has been developed and validated for the quantitative determination of four azo dyes (Para red, Solvent yellow 2, Solvent red 1 and Sudan red 7B) in rat plasma using D 5 -Sudan I as the internal standard. The optimal separation was accomplished on an Agilent Eclipse Plus C18 column (100 × 2.1 mm, 1.8 μm) with gradient elution using the mobile phase including acetonitrile and water (containing 0.1% formic acid). The flow rate was 0.45 mL/min. The detection was conducted by means of electrospray ionization mass spectrometry in positive ion mode with multiple reaction monitoring. The calibration curves showed good linearity, with correlation coefficients >0.998 for all of the analytes within the concentration range. The lower limits of quantification (LLOQs) of Para red, Solvent yellow 2, Solvent red 1 and Sudan red 7B in rat plasma were 1.0, 0.1, 0.1 and 0.1 μg/L, respectively. The intra- and interday relative standard deviations were ≤9.6 and ≤12.4%, respectively, and the accuracy was in the range of -5.8 to -9.5%. The average recoveries were between 81.49 and 118.65%, and the matrix effects were satisfactory in the biological matrices. The fully validated method has been successfully applied in measuring levels of the four azo dyes in rat plasma following oral administration of 20.0 mg/kg of analytes in rats, which was suitable for the pharmacokinetic studies of the azo dyes. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Color and polyphenolic stability in extracts produced from muscadine grape (Vitis rotundifolia) pomace.

    PubMed

    Cardona, Jorge A; Lee, Joon-Hee; Talcott, Stephen T

    2009-09-23

    The muscadine grape ( Vitis rotundifolia ) industry of the southern United States is largely devoid of value-added processes that capture the phytochemical content of wine and juice byproducts. Methods to recover and stabilize polyphenolics from muscadine grape pomace following juice manufacture were evaluated in laboratory-scale and pilot-scale trials. In laboratory-scale trials using osmotic equilibration, water-based extracts from juice pomace initially extracted 31-42% of total polyphenolics, 26-32% of total ellagic acid, and 36-62% of total anthocyanins. When adsorbed onto Amberlite XAD-4 resin to concentrate polyphenolics, these extracts lost 10.5% of their total ellagic acid from inefficient adsorption to the solid phase support. Subsequent pilot-scale trials were evaluated using hot water extracts from grape juice pomace followed by aerobic yeast fermentation to remove sugars and comparison to reversed phase C(18) and Amberlite XAD-4. Extracts were also concentrated using spray-drying and vacuum evaporation. Fermentation had a minor impact on the retention of most polyphenolic compounds evaluated, yet resulted in a 16.3% decrease in antioxidant capacity. Spray-drying resulted in a 30.3% loss in total anthocyanins, a 21.5% loss in total phenolics, and a 23.3% decrease in antioxidant activity, whereas vacuum evaporation had no deleterious impact on these parameters. The physiology of the muscadine grape and its unique phytochemical composition has limited utilization of pomace from wine and juice manufacture. However, these studies demonstrated the potential to extract and concentrate polyphenolic-rich extracts for use in value-added applications.

  12. Determination of Aroclor 1260 in soil samples by gas chromatography with mass spectrometry and solid-phase microextraction.

    PubMed

    Zhang, Mengliang; Jackson, Glen P; Kruse, Natalie A; Bowman, Jennifer R; Harrington, Peter de B

    2014-10-01

    A novel fast screening method was developed for the determination of polychlorinated biphenyls that are constituents of the commercial mixture, Aroclor 1260, in soil matrices by gas chromatography with mass spectrometry combined with solid-phase microextraction. Nonequilibrium headspace solid-phase microextraction with a 100 μm polydimethylsiloxane fiber was used to extract polychlorinated biphenyls from 0.5 g of soil matrix. The use of 2 mL of saturated potassium dichromate in 6 M sulfuric acid solution improved the reproducibility of the extractions and the mass transfer of the polychlorinated biphenyls from the soil matrix to the microextraction fiber via the headspace. The extraction time was 30 min at 100°C. The percent recoveries, which were evaluated using an Aroclor 1260 standard and liquid injection, were within the range of 54.9-65.7%. Two-way extracted ion chromatogram data were used to construct calibration curves. The relative error was <±15% and the relative standard deviation was <15%, which are respective measures of the accuracy and precision. The method was validated with certified soil samples and the predicted concentrations for Aroclor 1260 agreed with the certified values. The method was demonstrated to be linear from 10 to 1000 ng/g for Aroclor 1260 in dry soil. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Mixed-mode sorption of hydroxylated atrazine degradation products to sell: A mechanism for bound residue

    USGS Publications Warehouse

    Lerch, R.N.; Thurman, E.M.; Kruger, E.L.

    1997-01-01

    This study tested the hypothesis that sorption of hydroxylated atrazine degradation products (HADPs: hydroxyatrazine, HA; deethylhydroxyatrazine, DEHA; and deisopropylhydroxyatrazine, DIHA) to soils occurs by mixed-mode binding resulting from two simultaneous mechanisms: (1) cation exchange and (2) hydrophobic interaction. The objective was to use liquid chromatography and soil extraction experiments to show that mixed-mode binding is the mechanism controlling HADP sorption to soils and is also a mechanism for bound residue. Overall, HADP binding to solid-phase extraction (SPE) sorbents occurred in the order: cation exchange >> octadecyl (C18) >> cyanopropyl. Binding to cation exchange SPE and to a high-performance liquid chromatograph octyl (C8) column showed evidence for mixed-mode binding. Comparison of soil extracted by 0.5 M KH2P04, pH 7.5, or 25% aqueous CH3CN showed that, for HA and DIHA, cation exchange was a more important binding mechanism to soils than hydrophobic interaction. Based on differences between several extractants, the extent of HADP mixed-mode binding to soil occurred in the following order: HA > DIHA > DEHA. Mixed-mode extraction recovered 42.8% of bound atrazine residues from aged soil, and 88% of this fraction was identified as HADPs. Thus, a significant portion of bound atrazine residues in soils is sorbed by the mixed-mode binding mechanisms.

  14. Simultaneous determination of 9 heterocyclic aromatic amines in pork products by liquid chromatography coupled with triple quadrupole tandem mass spectrometry

    NASA Astrophysics Data System (ADS)

    Shen, X. C.; Zhang, Y. L.; Cui, Y. Q.; Xu, L. Y.; Li, X.; Qi, J. H.

    2017-07-01

    Heterocyclic aromatic amines (HAAs) are potent mutagens that formed at high temperature in cooked, protein-rich food. Owing to their frequent intake, an accurate method is essential to access human health risk of HAAs exposure through detecting these compounds in various heat-treated meat products. In this study, a liquid chromatography-electrospray tandem mass spectrometry (LC--ESI-MS/MS) method was developed to perform the determination of 9 mutagenic heterocyclic amines (HAAs) in meat samples with multiple reaction monitoring (MRM) mode. Ultrasound assisted extraction and diatomaceous earth was employed to extract HAAs from food samples, and the analytes were purified and enriched using tandem solid phase extraction, with propyl sulfonic acid coupled to a C18 cartridge. Two parameters, extraction time and eluent, were carefully optimized to improve the extraction and purification efficiency. The LC separation was carried out using a Zorbax SB-C18 (3.5 μm particle size, 2.1 × 150 mm i.d.) column and optimized some parameters, such as pH, concentration and volume. Under the optimal experimental conditions, recoveries ranged from 52.97% to 97.11% with good quality parameters: limit of detection values between 0.02 and 0.24 ng mL-1, linearity (R2>0.998), and run-to-run and day-to-day precisions lower than 9.81% achieved. To evaluate the performance of the method in high throughput analysis of complex meat samples, the LC-MS/MS method was applied to the analysis of HAAs in three food samples, and the results demonstrated that the method can be used for the trace determination of HAAs in pork samples.

  15. Stability of steviol glycosides in several food matrices.

    PubMed

    Jooken, Etienne; Amery, Ruis; Struyf, Tom; Duquenne, Barbara; Geuns, Jan; Meesschaert, Boudewijn

    2012-10-24

    As steviol glycosides are now allowed as a food additive in the European market, it is important to assess the stability of these steviol glycosides after they have been added to different food matrices. We analyzed and tested the stability of steviol glycosides in semiskimmed milk, soy drink, fermented milk drink, ice cream, full-fat and skimmed set yogurt, dry biscuits, and jam. The fat was removed by centrifugation from the dairy and soy drink samples. Proteins were precipitated by the addition of acetonitrile and also removed by centrifugation. Samples of jam were extracted with water. Dry biscuits were extracted with ethanol. The resulting samples were concentrated with solid-phase extraction and analyzed by high-performance liquid chromatography on a C18 stationary phase and a gradient of acetonitrile/aqueous 25 mM phosphoric acid. The accuracy was checked using a standard addition on some samples. For assessing the stability of the steviol glycosides, samples were stored in conditions relevant to each food matrix and analyzed periodically. The results indicate that steviol glycosides can be analyzed with good precision and accuracy in these food categories. The recovery was between 96 and 103%. The method was also validated by standard addition, which showed excellent agreement with the external calibration curve. No sign of decomposition of steviol glycosides was found in any of the samples.

  16. Molecularly imprinted polymer cartridges coupled to high performance liquid chromatography (HPLC-UV) for simple and rapid analysis of fenthion in olive oil.

    PubMed

    Bakas, Idriss; Ben Oujji, Najwa; Istamboulié, Georges; Piletsky, Sergey; Piletska, Elena; Ait-Addi, Elhabib; Ait-Ichou, Ihya; Noguer, Thierry; Rouillon, Régis

    2014-07-01

    A combination of molecular modelling and a screening of the library of non-imprinted polymers (NIPs) was used to identify acrylamide as a functional monomer with high affinity towards fenthion, organophosphate insecticide, which is frequently used in the treatment of olives. A good correlation was found between the screening tests and modelling of monomer-template interactions performed using a computational approach. Acrylamide-based molecularly imprinted polymer (MIP) and non-imprinted polymer (NIP) were thermally synthesised in dimethyl formamide (porogen) using ethylene glycol dimethacrylate as a cross-linker and 1,1-azo-bis (isobutyronitrile) as an initiator. The chemical and physical properties of the prepared polymers were characterised. The binding of fenthion by the polymers was studied using solvents with different polarities. The developed MIP showed a high selectivity towards fenthion, compared to other organophosphates (dimethoate, methidathion malalthion), and allowed extraction of fenthion from olive oil samples with a recovery rate of about 96%. The extraction of fenthion using MIPs was much more effective than traditional C18 reverse-phase solid phase extraction and allowed to achieve a low detection limit (LOD) (5 µg L(-1)). Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Chemopreventive effects of free and bound phenolics associated to steep waters (nejayote) obtained after nixtamalization of different maize types.

    PubMed

    Rojas-García, Carlos; García-Lara, Silverio; Serna-Saldivar, Sergio O; Gutiérrez-Uribe, Janet A

    2012-03-01

    Free and bound phenolics extracts from nejayote solids were obtained after optimally lime-cooking blue, normal white, red, normal yellow, high-carotenoid and quality protein maize types. The extraction yield ranged from 4.47 to 10.05%. Bound phenolics extracts had higher content of total phenolics, antioxidant activity and ferulic acid compared to the free phenolics extracts. In general, free phenolics extracts were less cytotoxic than the bound phenolics counterparts. Bound phenolics extracts had higher induction of quinone reductase (QR) and particularly the normal yellow nejayote exerted the highest chemopreventive index tested in Hepa1c1c7 cells. When tested for monofunctional phase 2 induction capacity in BPrc1 cells, the bound phenolics extracts of blue, normal white and quality protein nejayotes were better inducers than the normal yellow counterpart. Particularly, the free phenolics extract of the white maize nejayote induced BPrc1 cells QR and exerted a higher chemopreventive index compared to the bound phenolics extract. Therefore, the nejayote of the normal white maize was the best source of monofunctional phase 2 enzyme inducers.

  18. Microwave assisted solid phase extraction for separation preconcentration sulfamethoxazole in wastewater using tyre based activated carbon as solid phase material prior to spectrophotometric determination.

    PubMed

    Mogolodi Dimpe, K; Mpupa, Anele; Nomngongo, Philiswa N

    2018-01-05

    This work was chiefly encouraged by the continuous consumption of antibiotics which eventually pose harmful effects on animals and human beings when present in water systems. In this study, the activated carbon (AC) was used as a solid phase material for the removal of sulfamethoxazole (SMX) in wastewater samples. The microwave assisted solid phase extraction (MASPE) as a sample extraction method was employed to better extract SMX in water samples and finally the analysis of SMX was done by the UV-Vis spectrophotometer. The microwave assisted solid phase extraction method was optimized using a two-level fractional factorial design by evaluating parameters such as pH, mass of adsorbent (MA), extraction time (ET), eluent ratio (ER) and microwave power (MP). Under optimized conditions, the limit of detection (LOD) and limit of quantification (LOQ) were 0.5μgL -1 and 1.7μgL -1 , respectively, and intraday and interday precision expressed in terms of relative standard deviation were >6%.The maximum adsorption capacity was 138mgg -1 for SMX and the adsorbent could be reused eight times. Lastly, the MASPE method was applied for the removal of SMX in wastewater samples collected from a domestic wastewater treatment plant (WWTP) and river water. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Determination of hydroxytyrosol and tyrosol by liquid chromatography for the quality control of cosmetic products based on olive extracts.

    PubMed

    Miralles, Pablo; Chisvert, Alberto; Salvador, Amparo

    2015-01-01

    An analytical method for the simultaneous determination of hydroxytyrosol and tyrosol in different types of olive extract raw materials and cosmetic cream samples has been developed. The determination was performed by liquid chromatography with UV spectrophotometric detection. Different chromatographic parameters, such as mobile phase pH and composition, oven temperature and different sample preparation variables were studied. The best chromatographic separation was obtained under the following conditions: C18 column set at 35°C and isocratic elution of a mixture ethanol: 1% acetic acid solution at pH 5 (5:95, v/v) as mobile phase pumped at 1 mL min(-1). The detection wavelength was set at 280 nm and the total run time required for the chromatographic analysis was 10 min, except for cosmetic cream samples where 20 min runtime was required (including a cleaning step). The method was satisfactorily applied to 23 samples including solid, water-soluble and fat-soluble olive extracts and cosmetic cream samples containing hydroxytyrosol and tyrosol. Good recoveries (95-107%) and repeatability (1.1-3.6%) were obtained, besides of limits of detection values below the μg mL(-1) level. These good analytical features, as well as its environmentally-friendly characteristics, make the presented method suitable to carry out both the control of the whole manufacture process of raw materials containing the target analytes and the quality control of the finished cosmetic products. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. The Solid Phase Curing Time Effect of Asbuton with Texapon Emulsifier at the Optimum Bitumen Content

    NASA Astrophysics Data System (ADS)

    Sarwono, D.; Surya D, R.; Setyawan, A.; Djumari

    2017-07-01

    Buton asphalt (asbuton) could not be utilized optimally in Indonesia. Asbuton utilization rate was still low because the processed product of asbuton still have impracticable form in the term of use and also requiring high processing costs. This research aimed to obtain asphalt products from asbuton practical for be used through the extraction process and not requiring expensive processing cost. This research was done with experimental method in laboratory. The composition of emulsify asbuton were 5/20 grain, premium, texapon, HCl, and aquades. Solid phase was the mixture asbuton 5/20 grain and premium with 3 minutes mixing time. Liquid phase consisted texapon, HCl and aquades. The aging process was done after solid phase mixing process in order to reaction and tie of solid phase mixed become more optimal for high solubility level of asphalt production. Aging variable time were 30, 60, 90, 120, and 150 minutes. Solid and liquid phase was mixed for emulsify asbuton production, then extracted for 25 minutes. Solubility level of asphalt, water level, and asphalt characteristic was tested at extraction result of emulsify asbuton with most optimum ashphal level. The result of analysis tested data asphalt solubility level at extract asbuton resulted 94.77% on 120 minutes aging variable time. Water level test resulted water content reduction on emulsify asbuton more long time on occurring of aging solid phase. Examination of asphalt characteristic at extraction result of emulsify asbuton with optimum asphalt solubility level, obtain specimen that have rigid and strong texture in order that examination result have not sufficient ductility and penetration value.

  1. Unavoidable food supply chain waste: acid-free pectin extraction from mango peel via subcritical water.

    PubMed

    Xia, H; Matharu, A S

    2017-09-21

    Mango peel is the major by-product of mango processing, and compromises 7-24% of the total mango weight. In this study, pectin was extracted from mango peel waste by using subcritical water extraction (SWE) in the absence of mineral acid. A highest yield of 18.34% was achieved from the Kesar variety and the pectin was characterised using ATR-IR spectroscopy, TGA and 13 C solid-state NMR spectroscopy to confirm the structure. The degree of esterification (DE) of the pectin was analysed with both titrimetry and 13 C solid-state NMR spectroscopy, and a high DE (>70%) was observed for all three varieties (Keitt, Sindhri and Kesar). This is the first report on acid-free subcritical water extraction of pectin from mango peel, which provides a green route for the valorisation of mango peel waste and contributes to a source of biobased materials and chemicals for a sustainable 21 st century.

  2. Fluidics platform and method for sample preparation

    DOEpatents

    Benner, Henry W.; Dzenitis, John M.

    2016-06-21

    Provided herein are fluidics platforms and related methods for performing integrated sample collection and solid-phase extraction of a target component of the sample all in one tube. The fluidics platform comprises a pump, particles for solid-phase extraction and a particle-holding means. The method comprises contacting the sample with one or more reagents in a pump, coupling a particle-holding means to the pump and expelling the waste out of the pump while the particle-holding means retains the particles inside the pump. The fluidics platform and methods herein described allow solid-phase extraction without pipetting and centrifugation.

  3. Micro versus macro solid phase extraction for monitoring water contaminants: a preliminary study using trihalomethanes.

    PubMed

    Alexandrou, Lydon D; Spencer, Michelle J S; Morrison, Paul D; Meehan, Barry J; Jones, Oliver A H

    2015-04-15

    Solid phase extraction is one of the most commonly used pre-concentration and cleanup steps in environmental science. However, traditional methods need electrically powered pumps, can use large volumes of solvent (if multiple samples are run), and require several hours to filter a sample. Additionally, if the cartridge is open to the air volatile compounds may be lost and sample integrity compromised. In contrast, micro cartridge based solid phase extraction can be completed in less than 2 min by hand, uses only microlitres of solvent and provides comparable concentration factors to established methods. It is also an enclosed system so volatile components are not lost. The sample can also be eluted directly into a detector (e.g. a mass spectrometer) if required. However, the technology is new and has not been much used for environmental analysis. In this study we compare traditional (macro) and the new micro solid phase extraction for the analysis of four common volatile trihalomethanes (trichloromethane, bromodichloromethane, dibromochloromethane and tribromomethane). The results demonstrate that micro solid phase extraction is faster and cheaper than traditional methods with similar recovery rates for the target compounds. This method shows potential for further development in a range of applications. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Recent developments and future trends in solid phase microextraction techniques towards green analytical chemistry.

    PubMed

    Spietelun, Agata; Marcinkowski, Łukasz; de la Guardia, Miguel; Namieśnik, Jacek

    2013-12-20

    Solid phase microextraction find increasing applications in the sample preparation step before chromatographic determination of analytes in samples with a complex composition. These techniques allow for integrating several operations, such as sample collection, extraction, analyte enrichment above the detection limit of a given measuring instrument and the isolation of analytes from sample matrix. In this work the information about novel methodological and instrumental solutions in relation to different variants of solid phase extraction techniques, solid-phase microextraction (SPME), stir bar sorptive extraction (SBSE) and magnetic solid phase extraction (MSPE) is presented, including practical applications of these techniques and a critical discussion about their advantages and disadvantages. The proposed solutions fulfill the requirements resulting from the concept of sustainable development, and specifically from the implementation of green chemistry principles in analytical laboratories. Therefore, particular attention was paid to the description of possible uses of novel, selective stationary phases in extraction techniques, inter alia, polymeric ionic liquids, carbon nanotubes, and silica- and carbon-based sorbents. The methodological solutions, together with properly matched sampling devices for collecting analytes from samples with varying matrix composition, enable us to reduce the number of errors during the sample preparation prior to chromatographic analysis as well as to limit the negative impact of this analytical step on the natural environment and the health of laboratory employees. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Kinetic controls on the complexation between mercury and dissolved organic matter in a contaminated environment.

    PubMed

    Miller, Carrie L; Southworth, George; Brooks, Scott; Liang, Liyuan; Gu, Baohua

    2009-11-15

    The interaction of mercury (Hg) with dissolved natural organic matter (NOM) under equilibrium conditions is the focus of many studies but the kinetic controls on Hg-NOM complexation in aquatic systems have often been overlooked. We examined the rates of Hg-NOM complexation both in a contaminated Upper East Fork Poplar Creek (UEFPC) in Oak Ridge, Tennessee, and in controlled laboratory experiments using reducible Hg (Hg(R)) measurements and C(18) solid phase extraction techniques. Of the filterable Hg at the headwaters of UEFPC, >90% was present as Hg(R) and this fraction decreased downstream but remained >29% of the filterable Hg at all sites. The presence of higher Hg(R) concentrations than would be predicted under equilibrium conditions in UEFPC and in experiments with a NOM isolate suggests that kinetic reactions are controlling the complexation between Hg and NOM. The slow formation of Hg-NOM complexes is attributed to competitive ligand exchange among various moieties and functional groups in NOM with a range of binding strengths and configurations. This study demonstrates the need to consider the effects of Hg-NOM complexation kinetics on processes such as Hg methylation and solid phase partitioning.

  6. Multivariate optimization of the factors influencing the solid-phase microextraction of pyrethroid pesticides in water.

    PubMed

    Casas, Vanessa; Llompart, Maria; García-Jares, Carmen; Cela, Rafael; Dagnac, Thierry

    2006-08-18

    A method based on solid-phase microextraction (SPME) and gas chromatography with micro-electron capture detection (GC-microECD) has been optimized for the analysis of pyrethroids in water samples. The influence of parameters such as temperature, fibre coating, salting-out effect and sampling mode on the extraction efficiency has been studied by means of a mix-level factorial design, which allowed the study of main effects as well as two factor interactions. Finally, a method based on direct SPME at 50 degrees C, using polydimethylsiloxane fibre is proposed. The method showed good linearity (R2>0.995) and repeatability (RSD

  7. Simultaneous determination of five minor coumarins and flavonoids in Glycyrrhiza uralensis by solid-phase extraction and high-performance liquid chromatography/electrospray ionization tandem mass spectrometry.

    PubMed

    Qiao, Xue; Liu, Chun-Fang; Ji, Shuai; Lin, Xiong-Hao; Guo, De-An; Ye, Min

    2014-02-01

    Minor phenolic compounds in licorice (Glycyrrhiza uralensis) have recently been proved for diverse bioactivities and favorable bioavailability, indicating that they may play an important role in the therapeutic effects or herb-drug interactions of licorice. However, so far, their abundance in licorice remains unknown. In this study, a reliable solid-phase extraction coupled with a high-performance liquid chromatography and diode array detection method was established to determine the minor phenolic compounds in licorice. The analytes were enriched by a three-step solid-phase extraction method, and then separated on a YMC ODS-A column by gradient elution. Five coumarins and flavonoids were identified by electrospray ionization tandem mass spectrometry, and then quantified using high-performance liquid chromatography and diode array detection. The amounts of glycycoumarin, dehydroglyasperin C, glycyrol, licoflavonol, and glycyrin in G. uralensis were 0.81 ± 0.28, 1.25 ± 0.59, 0.20 ± 0.08, 0.12 ± 0.04, and 0.17 ± 0.08 mg/g, respectively. Abundances of these compounds in other Glycyrrhiza species (G. glabra, G. inflata, and G. yunnanesis) were remarkably lower than G. uralensis. Georg Thieme Verlag KG Stuttgart · New York.

  8. Raman effect in multiferroic Bi5Fe1+xTi3-xO15 solid solutions: A temperature study

    NASA Astrophysics Data System (ADS)

    Rodríguez Aranda, Ma. Del Carmen; Rodríguez-Vázquez, Ángel G.; Salazar-Kuri, Ulises; Mendoza, María Eugenia; Navarro-Contreras, Hugo R.

    2018-02-01

    In this work, a Raman study of powder samples of multiferroic Bi5Fe1+xTi3-xO15 solid solutions and Bi6Fe2Ti3O18 as a function of temperature from 27 °C (room temperature) to 850 °C is presented. The values of x (i.e., the Fe composition) for the solid solutions were 1.0, 1.1, 1.3, and 1.4. The temperature coefficients of eight phonon frequencies were determined for all the samples. The large observed phonon broadenings with increasing temperature precluded the observation of several of the phonon bands above defined temperatures in the range of 200-700 °C depending on the sample. These phonon broadenings were explained on the basis of the Klemens model, which considers that the broadenings are due to the thermal expansion of the lattice with a major contribution in terms of magnitude from anharmonic phonon-phonon interactions. However, some evidence for the presence of several of the phonons persisted up to 800-850 °C. These solid solutions are expected to exhibit a ferroelectric-paraelectric phase transition at 742 to 750 °C and a ferromagnetic-antiferromagnetic transition at 426 °C. We also observed changes in the slopes of the temperature dependence of the phonon frequencies for the lines at 228 cm-1 for Bi5FeTi3O15 and 330 cm-1 for Bi6Fe2Ti3O18 at temperatures of 247 °C and 347 °C, respectively. No similar temperature-frequency slope changes indicative of possible phase transitions were observed for any of the phonon lines of the other three Bi5Fe1+xTi3-xO15 solid solutions examined.

  9. Analysis of lignin oxidation products in a stalagmite from the Herbstlabyrinth-Adventshöhle in Germany and comparison with δ13C and other vegetation proxies

    NASA Astrophysics Data System (ADS)

    Heidke, Inken; Mischel, Simon A.; Scholz, Denis; Hoffmann, Thorsten

    2017-04-01

    Lignin oxidation products (LOPs) are widely used as vegetation proxies in sediment cores and natural waters and can be found in speleothems, too. They not only indicate the quantity of vegetation, but also allow to differentiate between angiosperm and gymnosperm plant sources and woody and herbaceous plant material. Lignin is one of the main constituents of wood and woody plants. It is a biopolymer that mainly consists of three monomers, p-coumaryl alcohol, coniferyl alcohol and sinapyl alcohol. The proportion of these three monomers varies with the type of vegetation. To analyse the composition of lignin particles in speleothems, it is necessary to extract the speleothem samples, to digest the lignin polymer in order to split it into its monomeric oxidation products, and to quantify these LOPs.[1] In the method we are presenting here, stalagmite samples are dissolved in hydrochloric acid and the acidic solution is extracted by solid phase extraction. The resulting organic fraction is submitted to an alkaline cupric oxide oxidation using a microwave digestion system.[2] The LOPs are enriched by solid phase extraction and analysed by ultra-high performance liquid chromatography coupled to electrospray high resolution mass spectrometry (UHPLC-ESI-HRMS). We used this method to analyse the 11000 years old stalagmite NG01 from the Herbstlabyrinth-Adventshöhle cave in Germany.[3] The stalagmite slab was cut in oblong pieces following the growth lines so that the sample weight was ca. 3-5 g and the sample length along the growth axis was ca. 1 cm, corresponding to a time resolution of ca. 200 years per sample. We present the first LOP record of a stalagmite as well as the method validation. The results of the LOP analysis were compared with records of δ13C, δ18O and trace elements of the same stalagmite analysed by Mischel et al. (2016).[3] References [1] C. N. Jex, G. H. Pate, A. J. Blyth, R. G. Spencer, P. J. Hernes, S. J. Khan, A. Baker, Quaternary Science Reviews 2014, 87, 46-59. [2] M. A. Gon i, S. Montgomery, Analytical chemistry 2000, 72, 3116-3121. [3] S. A. Mischel, D. Scholz, C. Spötl, K. P. Jochum, A. Schröder-Ritzrau, S. Fiedler, The Holocene 2016.

  10. Validation of a method for the determination of zolpidem in human plasma using LC with fluorescence detection.

    PubMed

    Ring, P R; Bostick, J M

    2000-04-01

    A sensitive and selective high-performance liquid chromatography (HPLC) method was developed for the determination of zolpidem in human plasma. Zolpidem and the internal standard (trazodone) were extracted from human plasma that had been made basic. The basic sample was loaded onto a conditioned Bond Elut C18 cartridge, rinsed with water and eluted with methanol. Forty microliters were then injected onto the LC system. Separation was achieved on a C18 column (150 x 4.6 mm, 5 microm) with a mobile phase composed of acetonitrile:50 mM potassium phosphate monobasic at pH 6.0 (4:6, v/v). Detection was by fluorescence, with excitation at 254 nm and emission at 400 nm. The retention times of zolpidem and internal standard were approximately 4.7 and 5.3 min, respectively. The LC run time was 8 min. The assay was linear in concentration range 1-400 ng/ml for zolpidem in human plasma. The analysis of quality control samples for zolpidem (3, 30, and 300 ng/ml) demonstrated excellent precision with relative standard deviations (RSD) of 3.7, 4.6, and 3.0%, respectively (n = 18). The method was accurate with all intraday (n = 6) and overall (n = 18) mean concentrations within 5.8% from nominal at all quality control sample concentrations. This method was also performed using a Gilson Aspec XL automated sample processor and autoinjector. The samples were manually fortified with internal standard and made basic. The aspec then performed the solid phase extraction and made injections of the samples onto the LC system. Using the automated procedure for analysis, quality control samples for zolpidem (3, 30, and 300 ng/ml) demonstrated acceptable precision with RSD values of 9.0, 4.9, and 5.1%, respectively (n = 12). The method was accurate with all intracurve (n = 4) and overall (n = 12) mean values being less than 10.8% from nominal at all quality control sample concentrations.

  11. Molecularly imprinted solid-phase extraction in the analysis of agrochemicals.

    PubMed

    Yi, Ling-Xiao; Fang, Rou; Chen, Guan-Hua

    2013-08-01

    The molecular imprinting technique is a highly predeterminative recognition technology. Molecularly imprinted polymers (MIPs) can be applied to the cleanup and preconcentration of analytes as the selective adsorbent of solid-phase extraction (SPE). In recent years, a new type of SPE has formed, molecularly imprinted polymer solid-phase extraction (MISPE), and has been widely applied to the extraction of agrochemicals. In this review, the mechanism of the molecular imprinting technique and the methodology of MIP preparations are explained. The extraction modes of MISPE, including offline and online, are discussed, and the applications of MISPE in the analysis of agrochemicals such as herbicides, fungicides and insecticides are summarized. It is concluded that MISPE is a powerful tool to selectively isolate agrochemicals from real samples with higher extraction and cleanup efficiency than commercial SPE and that it has great potential for broad applications.

  12. Evaluation of the Use of Supercritical Fluids for the Extraction of Explosives and Their Degradation Products from Soil

    DTIC Science & Technology

    1994-04-01

    and nontoxic is a major pounds. advantage . The accepted analytical method for explosives, The basic equipment required to conduct SFE is SW846 Method...theoretical advantage of SFE tion (SlE) with 18-hour sonic extraction with ACN. compared to conventional solvent extraction. II T r Figure 1. Phase...diagram of C0 2.Temperature 31"C Shut-off Hewler Figure 2. Design for a basic SFE apparaztus. (After Hawthorne 1993.) The advantages of extraction

  13. Polypyrrole-magnetite dispersive micro-solid-phase extraction combined with ultraviolet-visible spectrophotometry for the determination of rhodamine 6G and crystal violet in textile wastewater.

    PubMed

    Kamaruddin, Amirah Farhan; Sanagi, Mohd Marsin; Wan Ibrahim, Wan Aini; Md Shukri, Dyia S; Abdul Keyon, Aemi S

    2017-11-01

    Polypyrrole-magnetite dispersive micro-solid-phase extraction method combined with ultraviolet-visible spectrophotometry was developed for the determination of selected cationic dyes in textile wastewater. Polypyrrole-magnetite was used as adsorbent due to its thermal stability, magnetic properties, and ability to adsorb Rhodamine 6G and crystal violet. Dispersive micro-solid-phase extraction parameters were optimized, including sample pH, adsorbent amount, extraction time, and desorption solvent. The optimum polypyrrole-magnetite dispersive micro-solid phase-extraction conditions were sample pH 8, 60 mg polypyrrole-magnetite adsorbent, 5 min of extraction time, and acetonitrile as the desorption solvent. Under the optimized conditions, the polypyrrole-magnetite dispersive micro-solid-phase extraction with ultraviolet-visible method showed good linearity in the range of 0.05-7 mg/L (R 2  > 0.9980). The method also showed a good limit of detection for the dyes (0.05 mg/L) and good analyte recoveries (97.4-111.3%) with relative standard deviations < 10%. The method was successfully applied to the analysis of dyes in textile wastewater samples where the concentration found was 1.03 mg (RSD ±7.9%) and 1.13 mg/L (RSD ± 4.6%) for Rhodamine 6G and crystal violet, respectively. It can be concluded that this method can be adopted for the rapid extraction and determination of dyes at trace concentration levels. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Design of C18 Organic Phases with Multiple Embedded Polar Groups for Ultraversatile Applications with Ultrahigh Selectivity.

    PubMed

    Mallik, Abul K; Qiu, Hongdeng; Oishi, Tomohiro; Kuwahara, Yutaka; Takafuji, Makoto; Ihara, Hirotaka

    2015-07-07

    For the first time, we synthesized multiple embedded polar groups (EPGs) containing linear C18 organic phases. The new materials were characterized by elemental analysis, IR spectroscopy, (1)H NMR, diffuse reflectance infrared Fourier transform (DRIFT), solid-state (13)C cross-polarization magic angle spinning (CP/MAS) NMR, suspended-state (1)H NMR, and differential scanning calorimetry (DSC). (29)Si CP/MAS NMR was carried out to investigate the degree of cross-linking of the silane and silane functionality of the modified silica. Solid-state (13)C CP/MAS NMR and suspended-state (1)H NMR spectroscopy indicated a higher alkyl chain order for the phase containing four EPGs than for the phase with three EPGs. To correlate the NMR results with temperature-dependent chromatographic studies, standard reference materials (SRM 869b and SRM 1647e), a column selectivity test mixture for liquid chromatography was employed. A single EPG containing the C18 phase was also prepared in a similar manner to be used as a reference column especially for the separation of basic and polar compounds in reversed-phase liquid chromatography (RPLC) and hydrophilic interaction liquid chromatography (HILIC), respectively. Detailed chromatographic characterization of the new phases was performed in terms of their surface coverage, hydrophobic selectivity, shape selectivity, hydrogen bonding capacity, and ion-exchange capacity at pH 2.7 and 7.6 for RPLC as well as their hydrophilicity, the selectivity for hydrophilic-hydrophobic substituents, the selectivity for the region and configurational differences in hydrophilic substituents, the evaluation of electrostatic interactions, and the evaluation of the acidic-basic nature for HILIC-mode separation. Furthermore, peak shapes for the basic analytes propranolol and amitriptyline were studied as a function of the number of EPGs on the C18 phases in the RPLC. The chromatographic performance of multiple EPGs containing C18 HILIC phases is illustrated by the separation of sulfa drugs, β-blockers, xanthines, nucleic acid bases, nucleosides, and water-soluble vitamins. Both of the phases showed the best performance for the separation of shape-constrained isomers, nonpolar, polar, and basic compounds in RPLC- and HILIC-mode separation of sulfa drugs, and other polar and basic analytes compared to the conventional alkyl phases with and without embedded polar groups and HILIC phases. Surprisingly, one phase would be able to serve the performance of three different types of phases with very high selectivity, and we named this phase the "smart phase". Versatile applications with a single column will reduce the column purchasing cost for the analyst as well as achieve high separation, which is challenging with the commercially available columns.

  15. Application of mercapto-silica polymerized high internal phase emulsions for the solid-phase extraction and preconcentration of trace lead(II).

    PubMed

    Su, Rihui; Ruan, Guihua; Chen, Zhengyi; Du, Fuyou; Li, Jianping

    2015-12-01

    A new class of solid-phase extraction column prepared with grafted mercapto-silica polymerized high internal phase emulsion particles was used for the preconcentration of trace lead. First, mercapto-silica polymerized high internal phase emulsion particles were synthesized by using high internal phase emulsion polymerization and carefully assembled in a polyethylene syringe column. The influences of various parameters including adsorption pH value, adsorption and desorption solvents, flow rate of the adsorption and desorption procedure were optimized, respectively, and the suitable uploading sample volumes, adsorption capacity, and reusability of solid phase extraction column were also investigated. Under the optimum conditions, Pb(2+) could be preconcentrated quantitatively over a wide pH range (2.0-5.0). In the presence of foreign ions, such as Na(+) , K(+) , Ca(2+) , Zn(2+) , Mg(2+) , Cu(2+) , Fe(2+) , Cd(2+) , Cl(-) and NO3 (-) , Pb(2+) could be recovered successfully. The prepared solid-phase extraction column performed with high stability and desirable durability, which allowed more than 100 replicate extractions without measurable changes of performance. The feasibility of the developed method was further validated by the extraction of Pb(2+) in rice samples. At three spiked levels of 40.0, 200 and 800 μg/kg, the average recoveries for Pb(2+) in rice samples ranged from 87.3 to 105.2%. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. High-performance liquid chromatography (HPLC) as a tool for monitoring the fate of fluazinam in soil.

    PubMed

    Hakala, Kati P; Tuomainen, Päivi M; Yli-Halla, Markku J; Hartikainen, Helinä

    2014-01-01

    Fluazinam is a widely used pesticide employed against the fungal disease late blight in potato cultivation. A specific, repeatable, and rapid high-performance liquid chromatography (HPLC) method utilizing a diode array detector (DAD) was developed to determine the presence of fluazinam in soil. The method consists of acetonitrile (ACN) extraction, clean-up with solid-phase extraction (SPE), and separation using a mobile phase consisting of 70% ACN and 30% water (v/v), including 0.02% acetic acid. HPLC was performed with a C18 column and the detection wavelength was 240 nm. The method was successfully applied to an incubation experiment and to soil samples taken from potato fields where fluazinam had been applied two to three times during the on-going growing season. In the 90-day incubation experiment, analytical standard fluazinam and the commercial fungicide Shirlan(®) were added to soil samples that had never been treated with fluazinam, and were then extracted with ACN and 0.01 M calcium chloride (CaCl2). Fluazinam was not extractable with CaCl2, indicating that it does not leach to watercourses in the dissolved form. Recovery with ACN extraction for sandy soils was 72-95% immediately after application and 53-73% after 90 days of incubation. Out of the eight potato field soil samples, fluazinam was found in two samples at concentrations of 2.1 mg kg(-1) and 1.9 mg kg(-1), well above the limit of quantification (0.1 mg kg(-1)).

  17. Aqueous two-phase assisted by ultrasound for the extraction of anthocyanins from Lycium ruthenicum Murr.

    PubMed

    Qin, Benlin; Liu, Xuecong; Cui, Haiming; Ma, Yue; Wang, Zimin; Han, Jing

    2017-10-21

    In this study, an efficient ultrasound-assisted aqueous two-phase extraction method was used for the extraction of anthocyanins from Lycium ruthenicum Murr. An ethanol/ammonium sulfate system was chosen for the aqueous two-phase system due to its fine partitioning and recycling behaviors. Single-factor experiments were conducted to determine the optimized composition of the system, and the response surface methodology was used for the further optimization of the ultrasound-assisted aqueous two-phase extraction. The optimal conditions were as follows: a salt concentration of 20%, an ethanol concentration of 25%, an extraction time of 33.7 min, an extraction temperature of 25°C, a liquid/solid ratio of 50:1 w/w, pH value of 3.98, and an ultrasound power of 600 W. Under the above conditions, the yields of anthocyanins reached 4.71 mg/g dry sample. For the further purification, D-101 resin was used, and the purity of anthocyanins reached 25.3%. In conclusion, ultrasound-assisted aqueous two-phase extraction was an efficient, ecofriendly, and economical method, and it may be a promising technique for extracting bioactive components from plants.

  18. Bioassay-guided supercritical fluid extraction of cyclooxygenase-2 inhibiting substances in Plantago major L.

    PubMed

    Stenholm, A; Göransson, U; Bohlin, L

    2013-02-01

    Selective extraction of plant materials is advantageous for obtaining extracts enriched with desired constituents, thereby reducing the need for subsequent chromatography purification. Such compounds include three cyclooxygenase-2 (COX-2) inhibitory substances in Plantago major L. targeted in this investigation: α-linolenic acid (α-LNA) (18:3 ω-3) and the triterpenic acids ursolic acid and oleanolic acid. To investigate the scope for tuning the selectivity of supercritical fluid extraction (SFE) using bioassay guidance, and Soxhlet extraction with dichloromethane as solvent as a reference technique, to optimise yields of these substances. Extraction parameters were varied to optimise extracts' COX-2/COX-1 inhibitory effect ratios. The crude extracts were purified initially using a solid phase extraction (SPE) clean-up procedure and the target compounds were identified with GC-MS, LC-ESI-MS and LC-ESI-MS² using GC-FID for quantification. α-LNA was preferentially extracted in dynamic mode using unmodified carbon dioxide at 40°C and 172 bar, at a 0.04% (w/w) yield with a COX-2/COX-1 inhibitory effect ratio of 1.5. Ursolic and oleanolic acids were dynamically extracted at 0.25% and 0.06% yields, respectively, with no traces of (α-LNA) and a COX-2/COX-1-inhibitory effect ratio of 1.1 using 10% (v/v) ethanol as polar modifier at 75°C and 483 bar. The Soxhlet extracts had ursolic acid, oleanolic acid and αLNA yields up to 1.36%, 0.34% and 0.15%, respectively, with a COX-2/COX-1 inhibitory effect ratio of 1.2. The target substances can be extracted selectively by bioassay guided optimisation of SFE conditions. Copyright © 2012 John Wiley & Sons, Ltd.

  19. Automated Mini-Column Solid-Phase Extraction Cleanup for High-Throughput Analysis of Chemical Contaminants in Foods by Low-Pressure Gas Chromatography-Tandem Mass Spectrometry.

    PubMed

    Lehotay, Steven J; Han, Lijun; Sapozhnikova, Yelena

    2016-01-01

    This study demonstrated the application of an automated high-throughput mini-cartridge solid-phase extraction (mini-SPE) cleanup for the rapid low-pressure gas chromatography-tandem mass spectrometry (LPGC-MS/MS) analysis of pesticides and environmental contaminants in QuEChERS extracts of foods. Cleanup efficiencies and breakthrough volumes using different mini-SPE sorbents were compared using avocado, salmon, pork loin, and kale as representative matrices. Optimum extract load volume was 300 µL for the 45 mg mini-cartridges containing 20/12/12/1 (w/w/w/w) anh. MgSO 4 /PSA (primary secondary amine)/C 18 /CarbonX sorbents used in the final method. In method validation to demonstrate high-throughput capabilities and performance results, 230 spiked extracts of 10 different foods (apple, kiwi, carrot, kale, orange, black olive, wheat grain, dried basil, pork, and salmon) underwent automated mini-SPE cleanup and analysis over the course of 5 days. In all, 325 analyses for 54 pesticides and 43 environmental contaminants (3 analyzed together) were conducted using the 10 min LPGC-MS/MS method without changing the liner or retuning the instrument. Merely, 1 mg equivalent sample injected achieved <5 ng g -1 limits of quantification. With the use of internal standards, method validation results showed that 91 of the 94 analytes including pairs achieved satisfactory results (70-120 % recovery and RSD ≤ 25 %) in the 10 tested food matrices ( n  = 160). Matrix effects were typically less than ±20 %, mainly due to the use of analyte protectants, and minimal human review of software data processing was needed due to summation function integration of analyte peaks. This study demonstrated that the automated mini-SPE + LPGC-MS/MS method yielded accurate results in rugged, high-throughput operations with minimal labor and data review.

  20. High-temperature solid-phase microextraction procedure for the detection of drugs by gas chromatography-mass spectrometry.

    PubMed

    Staerk, U; Külpmann, W R

    2000-08-18

    High-temperature headspace solid-phase microextraction (SPME) with simultaneous ("in situ") derivatisation (acetylation or silylation) is a new sample preparation technique for the screening of illicit drugs in urine and for the confirmation analysis in serum by GC-MS. After extraction of urine with a small portion of an organic solvent mixture (e.g., 2 ml of hexane-ethyl acetate) at pH 9, the organic layer is separated and evaporated to dryness in a small headspace vial. A SPME-fiber (e.g., polyacrylate) doped with acetic anhydride-pyridine (for acetylation) is exposed to the vapour phase for 10 min at 200 degrees C in a blockheater. The SPME fiber is then injected into the GC-MS for thermal desorption and analysis. After addition of perchloric acid and extraction with n-hexane to remove lipids, the serum can be analysed after adjusting to pH 9 as described for urine. Very clean extracts are obtained. The various drugs investigated could be detected and identified in urine by the total ion current technique at the following concentrations: amphetamines (200 microg/l), barbiturates (500 microg/l), benzodiazepines (100 microg/l), benzoylecgonine (150 microg/l), methadone (100 microg/l) and opiates (200 microg/l). In serum all drugs could be detected by the selected ion monitoring technique within their therapeutic range. As compared to liquid-liquid extraction only small amounts of organic solvent are needed and larger amounts of the pertinent analytes could be transferred to the GC column. In contrast to solid-phase extraction (SPE), the SPME-fiber is reusable several times (as there is no contamination by endogenous compounds). The method is time-saving and can be mechanised by the use of a dedicated autosampler.

  1. Development of a headspace-solid phase micro extraction method to monitor changes in volatile profile of rose (Rosa hybrida, cv David Austin) petals during processing.

    PubMed

    Bianchi, Giulia; Nuzzi, Monica; Avitabile Leva, Alexa; Rizzolo, Anna

    2007-05-25

    In the present study, headspace solid phase microextraction combined to capillary gas chromatography (HS-SPME-GC) has been applied for the determination of changes in the volatile profile of rose petals (Rosa hybrida, cvs David Austin) following processing (heat treatment and addition as an ingredient to a food product--for example yoghurt). Four SPME fibres at two sampling temperatures (40 and 60 degrees C) with a sampling time of 30 min were examined. Volatile profiles were detected either by FID or/and by olfactometry (ODP-II, Gerstel). Fibre testing was performed using raw rose petals for sampling temperature selection and an 18 characteristic rose volatile standard mixture in water was used to compare fibre performances at the sampling temperature of 60 degrees C. Polydimethylsiloxane-divinylbenzene (PDMS-DVB) fibre at the sampling temperature of 60 degrees C was the most suitable to sample the rose alcohols phenyl ethanol, citronellol, nerol, geraniol and eugenol, as assessed by GC-olfactometry, not only from raw petals, but also from processed rose petals and the food product. PDMS-DVB fibre also showed a desired low affinity to volatiles from yoghurt, which reduces the influence of food matrix on the volatile profile. The method was linear over two orders of magnitude and had satisfactory repeatability, with limits of detection for the rose alcohols ranging from <1 to 10 ng/ml concentration levels.

  2. Determination of alkylphenol and alkylphenolethoxylates in biota by liquid chromatography with detection by tandem mass spectrometry and fluorescence spectroscopy

    USGS Publications Warehouse

    Schmitz-Afonso, I.; Loyo-Rosales, J.E.; de la Paz Aviles, M.; Rattner, B.A.; Rice, C.P.

    2003-01-01

    A quantitative method for the simultaneous determination of octylphenol, nonylphenol and the corresponding ethoxylates (1 to 5) in biota is presented. Extraction methods were developed for egg and fish matrices based on accelerated solvent extraction followed by a solid-phase extraction cleanup, using octadecylsilica or aminopropyl cartridges. Identification and quantitation were accomplished by liquid chromatography-electrospray tandem mass spectrometry (LC-MS-MS) and compared to the traditional liquid chromatography with fluorescence spectroscopy detection. LC-MS-MS provides high sensitivity and specificity required for these complex matrices and an accurate quantitation with the use of 13C-labeled internal standards. Quantitation limits by LC-MS-MS ranged from 4 to 12 ng/g in eggs, and from 6 to 22 ng/g in fish samples. These methods were successfully applied to osprey eggs from the Chesapeake Bay and fish from the Great Lakes area. Total levels found in osprey egg samples were up to 18 ng/g wet mass and as high as 8.2 ug/g wet mass in the fish samples.

  3. Polymeric monolith column composited with multiwalled carbon nanotubes-β-cyclodextrin for the selective extraction of psoralen and isopsoralen.

    PubMed

    Ling, Xu; Zou, Li; Chen, Zilin

    2017-09-01

    A polymeric column that contains multiwalled carbon nanotubes-β-cyclodextrin composite was developed. The composite was wrapped into the poly(butyl methacrylate-ethylene dimethacrylate) monolith column (0.76 mm id and 10 cm in length). The column was then applied for the online solid-phase microextraction of psoralen and isopsoralen from Fructus Psoraleae. Following microextraction, the coumarins were quantified by high-performance liquid chromatography with C 18 separation column and UV detection. The effects of sample flow rate, sample volume, and pH value were optimized. The method showed low limits of detection (20 pg/mL, S/N = 3) for both psoralen and isopsoralen. Finally the method was successfully applied to the determination of psoralen and isopsoralen in spiked herb extracts and rat plasma where it gave recoveries that ranged between 93.2 and 102.1%. The empty hydrophobic cavities of β-cyclodextrin and the hydrophobicity of multiwalled carbon nanotubes provided specific extraction capability for psoralen and isopsoralen. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Carbon-Based Fe₃O₄ Nanocomposites Derived from Waste Pomelo Peels for Magnetic Solid-Phase Extraction of 11 Triazole Fungicides in Fruit Samples.

    PubMed

    Ren, Keyu; Zhang, Wenlin; Cao, Shurui; Wang, Guomin; Zhou, Zhiqin

    2018-05-06

    Carbon-based Fe₃O₄ nanocomposites (C/Fe₃O₄ NCs) were synthesized by a simple one-step hydrothermal method using waste pomelo peels as the carbon precursors. The characterization results showed that they had good structures and physicochemical properties. The prepared C/Fe₃O₄ NCs could be applied as excellent and recyclable adsorbents for magnetic solid phase extraction (MSPE) of 11 triazole fungicides in fruit samples. In the MSPE procedure, several parameters including the amount of adsorbents, extraction time, the type and volume of desorption solvent, and desorption time were optimized in detail. Under the optimized conditions, the good linearity ( R ² > 0.9916), the limits of detection (LOD), and quantification (LOQ) were obtained in the range of 1⁻100, 0.12⁻0.55, and 0.39⁻1.85 μg/kg for 11 pesticides, respectively. Lastly, the proposed MSPE method was successfully applied to analyze triazole fungicides in real apple, pear, orange, peach, and banana samples with recoveries in the range of 82.1% to 109.9% and relative standard deviations (RSDs) below 8.4%. Therefore, the C/Fe₃O₄ NCs based MSPE method has a great potential for isolating and pre-concentrating trace levels of triazole fungicides in fruits.

  5. Analysis and stability study of retinoids in pharmaceuticals by LC with fluorescence detection.

    PubMed

    Gatti, R; Gioia, M G; Cavrini, V

    2000-08-01

    Liquid chromatographic (HPLC) methods with fluorescence detection at different wavelengths were developed for measurements of retinoic acids (13-cis and all-trans) in pharmaceutical dosage forms and components of 'retinoid solution' (all-trans retinoic acid, vitamin A palmitate and beta-carotene), a galenical of 'Di Bella therapy', using reversed phase columns under isocratic conditions. The stability of all-trans retinoic acid in cream and all-trans retinoic acid and vitamin A palmitate in 'retinoid solution' was investigated. Solid-phase extraction (SPE), using C18 sorbent was applied to the analysis of retinoic acids (9-cis, 13-cis and all-trans) in the 'retinoid solution' to obtain a practical and reliable sample clean-up. The results showed that these preparations (cream and solution) can be conveniently stored in the dark (t.a. or 2-8 degrees C): under these conditions about 86-87% of the all-trans retinoic acid initial concentration in both formulations and about 73-78% of vitamin A palmitate in the 'retinoid solution' remained after 90 days, while under sunlight exposure rapid degradation of the drugs was observed.

  6. [Determination of three exogenous plant hormone residues in bean sprout by high performance liquid chromatography-quadrupole-time of flight mass spectrometry].

    PubMed

    Xie, Hanbing; Zhou, Mingying; Zhao, Haifeng; Wang, Yigang; Jiang, Wanfeng; Zhao, Shan

    2014-05-01

    This study was aimed to the establishment of an analytical method for the determination of three exogenous plant hormone residues in bean sprout by high performance liquid chromatography-quadrupole-time of flight mass spectrometry (HPLC-Q-TOF-MS). The target compounds were gibberellins, 6-benzylaminopurine and parachlorophenoxyacetic acid. The QuEChERS (quick, easy, cheap, effective, rugged, and safe) method was used for sample preparation. The analytes were extracted with a solution containing 1% (v/v, if not specified) acetic, 50% ethanol, 49% acetonitrile, and cleaned-up by dispersive solid-phase extraction with diatomite dispersant, then degreased by hexane. The three target compounds were separated on an Eclipse Plus C18 column (100 mm x 3.0 mm, 1.8 microm) with mobile phases A (water containing 0.1% formic acid) and B (methanol) by gradient elution within 15 min, and detected under negative electrospray ionization (ESI) mode. The quantitative analysis was carried out by extracting the peak area with accurate mass. The confirmatory analysis of the target compounds was performed with the qualitative fragments. The results showed that the limits of quantification (LOQs, S/N = 10) for the three target compounds were from 5.0 microg/kg to 10 microg/kg. The respective mean recoveries were found to be in the range of 79.1%-96.1%, and the RSDs were 5.7%-10.4%. It was applicable to the analysis of the three exogenous plant hormones in bean sprout samples. This method is simple, fast and efficient.

  7. A Novel MicroElectroMechanical System (MEMS) Device for Passive Sampling of Hydrophobic Compounds

    DTIC Science & Technology

    2011-05-01

    bioavailability  Samplers are removed, extracted for CoC, analyzed ▬ For organics: solid phase micro extraction ( SPME ) fibers, semi- permeable membrane...devices (SPMD), polyoxymethylene (POM) ▬ For metals: diffuse gradients in thin films (DGT) SPME fiber ESTCP project, Reible and Lotufo Applications to...Predict Bioaccumulation You et al. 2006, EST, 40: 6348 SPME concentrations were predictive of tissue concentrations of PCBs in field-contaminated

  8. Ion chromatographic methods for the detection of starch hydrolysis products in ruminal digesta.

    PubMed

    Barsuhn, K; Kotarski, S F

    1991-06-21

    Dionex high-performance ion chromatographic methods were evaluated for separation and quantitation of plant sugars and starch digestion products in the ruminal digesta of cattle. Mono- and disaccharides were eluted from a Dionex CarboPac PA1 column with sodium hydroxide used isocratically or as a pH gradient. Maltooligosaccharides which had a degree of polymerization (DP) less than 30 glucose residues were eluted in 60 min by a sodium hydroxide eluent containing a sodium acetate gradient. Carbohydrates were detected amperometrically. Responses were linear (r2 greater than 0.99) for glucose, disaccharides and maltooligosaccharides (DP less than 8). Precipitation and solid-phase extraction methods were evaluated for clean-up of samples of feedstuffs, ruminal contents, and bacterial culture fluids. Perchloric acid precipitation hydrolyzed sucrose but did not affect recoveries of cellobiose, isomaltose or maltose. Ethanol in concentrations of 79 and 86% precipitated maltooligosaccharides having chain lengths larger than 14 and 9 glucose residues, respectively. Maltooligosaccharide recoveries from solid-phase extraction columns varied with maltooligosaccharide size and column packing. Recoveries were greater than 94% for short chains (DP less than 6) eluted from phenyl-substituted columns and variable for all oligosaccharides eluted from C18 columns. Applications of these methods are presented and include: (1) detection of sugars in ruminant feed, (2) monitoring changes in ruminal sugars after feeding and (3) monitoring changes in extracellular sugars and oligosaccharides in the culture fluids of the ruminal bacterium, Bacteroides ruminicola.

  9. Molecularly imprinted polymer online solid-phase extraction coupled with high-performance liquid chromatography-UV for the determination of three sulfonamides in pork and chicken.

    PubMed

    He, Jinxing; Wang, Shuo; Fang, Guozhen; Zhu, Huaping; Zhang, Yan

    2008-05-14

    A selective imprinted amino-functionalized silica gel sorbent was prepared by combining a surface molecular imprinting technique with a sol-gel process for online solid-phase extraction-HPLC determination of three trace sulfonamides in pork and chicken muscle. The imprinted functionalized silica gel sorbent exhibited selectivity and fast kinetics for the adsorption and desorption of sulfonamides. With a sample loading flow rate of 4 mL min (-1) for 12.5 min, enhancement factors and detection limits for three sulfonamides ( S/ N = 3) were achieved. The precision (RSD) for nine replicate online sorbent extractions of 5 microg L (-1) sulfonamides was less than 4.5%. The sorbent also offered good linearity ( r (2) > 0.99) for online solid-phase extraction of trace levels of sulfonamides. The method was applied to the determination of sulfonamides in pork and chicken muscle samples. The prepared polymer sorbent shows promise for online solid-phase extraction for HPLC determination of trace levels of sulfonamides in pork and chicken samples.

  10. Determination of five pyrethroids in tea drinks by dispersive solid phase extraction with polyaniline-coated magnetic particles.

    PubMed

    Wang, Yuanpeng; Sun, Ying; Gao, Yan; Xu, Bo; Wu, Qiong; Zhang, Hanqi; Song, Daqian

    2014-02-01

    The polyaniline-coated magnetic particles with bowl-shaped morphology (Fe3O4/C/PANI microbowls) were successfully prepared and characterized by scanning electron microscopy, transmission electron microscopy and vibrating sample magnetometry. The prepared microbowls were used as the magnetic adsorbent in dispersive solid phase extraction of five pyrethroids, including cyhalothrin, beta-cypermethrin, esfenvalerate, permethrin and bifenthrin in plain tea drinks. The effects of experiment factors, including amount of Fe3O4/C/PANI microbowls, pH value, ultrasound extraction time and desorption conditions, were investigated. The extraction recoveries obtained with 8 mg of magnetic microbowls were satisfactory, and the microbowls can be reused after easy washing. Thus, a simple, selective and effective method for the determination of the pyrethroids was established successfully. The results showed that the method had good linearity (r=0.9992-0.9998), and the limits of detections (LODs) were from 0.025 to 0.032 ng mL(-1). The intra-day and inter-day relative standard deviations (RSDs) were in the range of 2.4-6.1% and 3.5-8.8%, respectively. Recoveries obtained by analyzing the real tea drinks were in the range of 72.1-118.4%. © 2013 Published by Elsevier B.V.

  11. Capillary-Channeled Polymer (C-CP) Fibers as a Stationary Phase for Sample Clean-Up of Protein Solutions for Matrix-Assisted Laser/Desorption Ionization Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Manard, Benjamin T.; Marcus, R. Kenneth

    2012-08-01

    Capillary-channeled polymer (C-CP) fibers are employed in a micropipette tip format to affect a stationary phase for the solid phase extraction (SPE) of proteins from buffer solutions prior to MALDI-MS analysis. Proteins readily adsorb to the polypropylene (PP) C-CP fibers while buffer species are easily washed off the tips using DI-H2O. Elution of the solutes is achieved with an aliquot of 50:50 ACN:H2O, which is compatible with the subsequent spotting on the MALDI target with the matrix solution. Lysozyme and cytochrome c are used as test species, with a primary buffer composition of 100 mM Tris-HCl. In this case, direct MALDI-MS produces no discernible protein signals. SPE on the C-CP fibers yields high fidelity mass spectra for 1 μL sample volumes. Limits of detection for cytochrome c in 100 mM Tris-HCl are on the order of 40 nM. Extraction of cytochrome c from buffer concentrations of up to 1 M Tris-HCl, provides signal recoveries that are suppressed by only ~50 % versus neat protein solutions. Finally, extraction of 3.1 μM cytochrome c from a synthetic urine matrix exhibits excellent recovery.

  12. Automated mini-column solid-phase extraction cleanup for high-throughput analysis of chemical contaminants in foods by low-pressure gas chromatography – tandem mass spectrometry

    USDA-ARS?s Scientific Manuscript database

    This study demonstrated the application of an automated high-throughput mini-cartridge solid-phase extraction (mini-SPE) cleanup for the rapid low-pressure gas chromatography – tandem mass spectrometry (LPGC-MS/MS) analysis of pesticides and environmental contaminants in QuEChERS extracts of foods. ...

  13. Comparison of characteristic flavor and aroma volatiles in melons and standards using solid phase microextraction (SPME) and Stir Bar Sorptive Extraction (SBSE) with GC-MS.

    USDA-ARS?s Scientific Manuscript database

    Stir bar sorptive extraction (SBSE) is a technique for extraction and analysis of organic compounds in aqueous matrices, similar in theory to solid phase microextraction (SPME). SBSE has been successfully used to analyze several organic compounds, including food matrices. When compared with SPME, ...

  14. QUANTITATION OF ESTROGENS IN GROUND WATER AND SWINE LAGOON SAMPLE USING SOLID PHASE EXTRACTION, PENTAFLUROBENZYL/TRIMETHYLSILYL DERIVATIZATIONS AND GAS CHROMATOGRAPHY NEGATIVE ION CHEMICAL IONIZATION/MASS SPECTROMETRY/MASS SPECTROMETRY

    EPA Science Inventory

    A method was developed for the confirmed identification and quantitation of 17B-estradiol, estrone, 17B-ethynylestrodial and 16a-hydroxy-17B-estradiol (estriol) in ground water and swine lagoon samples. Centrifuged and filtered samples were extracted using solid phase extraction...

  15. Semiautomated solid-phase extraction manifold with a solvent-level sensor.

    PubMed

    Orlando, R M; Rath, S; Rohwedder, J J R

    2013-11-15

    A semiautomated solid-phase extraction manifold for multiple extractions is presented. The manifold utilizes commercial solid-phase syringe cartridges and automatically introduces and elutes all the solvents during the extraction, reducing the typical workload and stress of the analyst. The manifold consists of a peristaltic pump with solenoid valves in a flow circuit that contains transmissive photomicrosensors. The photomicrosensors were used to control the solvent dispenser and the solvent level inside the cartridge. As solvent-level sensors, the photomicrosensors determined the exact time the solvent reached the top frit to avoid sorbent drying and accurately perform the solvent exchange. The repeatability of the manifold to introduce a particular volume of solvent into the cartridges was measured, and the precisions were between 0.05 and 2.89% (RSD). To evaluate the manifold, the amount of two fluoroquinolones in a fortified blank milk sample was determined. The results of the intra- and inter-day precision of multiple extractions from the fortified milk samples resulted in precisions better than 9.0% (RSD) and confirmed that the arrangement of the semiautomated manifold could adequately be used in solid-phase extraction with commercial cartridges. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Carbon coated magnetic nanoparticles as a novel magnetic solid phase extraction adsorbent for simultaneous extraction of methamphetamine and ephedrine from urine samples.

    PubMed

    Taghvimi, Arezou; Hamishehkar, Hamed

    2017-01-15

    This paper develops a highly selective, specific and efficient method for simultaneous determination of ephedrine and methamphetamine by a new carbon coated magnetic nanoparticles (C/MNPs) as a magnetic solid phase extraction (MSPE) adsorbent in biological urine medium. The characterization of synthesized magnetic nano adsorbent was completely carried out by various characterization techniques like Fourier transform infrared (FT-IR) spectroscopy, powder x-ray diffraction (XRD), scanning electron microscopy (SEM) and vibrating sample magnetometer (VSM). Nine important parameters influencing extraction efficiency including amount of adsorbent, amounts of sample volume, pH, type and amount of extraction organic solvent, time of extraction and desorption, agitation rate and ionic strength of extraction medium, were studied and optimized. Under optimized extraction conditions, a good linearity was observed in the concentration range of 100-2000ng/mL for ephedrine and 100-2500ng/mL for methamphetamine. Analysis of positive urine samples was carried out by proposed method with the recovery of 98.71 and 97.87% for ephedrine and methamphetamine, respectively. The results indicated that carbon coated magnetic nanoparticles could be applied in clinical and forensic laboratories for simultaneous determination of abused drugs in urine media. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Investigations on the emission of fragrance allergens from scented toys by means of headspace solid-phase microextraction gas chromatography-mass spectrometry.

    PubMed

    Masuck, Ines; Hutzler, Christoph; Luch, Andreas

    2010-04-30

    In the revised European toy safety directive 2009/48/EC the application of fragrance allergens in children's toys is restricted. The focus of the present work lies on the instrumental analytics of 13 banned fragrance allergens, as well as on 11 fragrance allergens that require declaration when concentrations surpass 100 microg per gram material. Applying a mixture of ethyl acetate and toluene solid/liquid extraction was performed prior to quantitative analysis of mass contents of fragrances in scented toys. In addition, an easy-to-perform method for the determination of emitted fragrances at 23 degrees C (handling conditions) or at 40 degrees C (worst case scenario) has been worked out to allow for the evaluation of potential risks originating from inhalation of these compounds during handling of or playing with toys. For this purpose a headspace solid-phase microextraction (HS-SPME) technique was developed and coupled to subsequent gas chromatography-mass spectrometry (GC-MS) analysis. Fragrance allergens were adsorbed (extracted) from the gas phase onto an 85 microm polyacrylate fiber while incubating pieces of the scented toys in sealed headspace vials at 23 degrees C and 40 degrees C. Quantification of compounds was performed via external calibration. The newly developed headspace method was subsequently applied to five perfumed toys. As expected, the emission of fragrance allergens from scented toys depends on the temperature and on the content of fragrance allergens present in those samples. In particular at conditions mimicking worst case (40 degrees C), fragrance allergens in toys may pose a risk to children since considerable amounts of compound might be absorbed by lung tissue via breathing of contaminated air. 2010 Elsevier B.V. All rights reserved.

  18. Multi-residue analysis method for analysis of pharmaceuticals using liquid chromatography-time of flight/mass spectrometry (LC-TOF/MS) in water sample

    NASA Astrophysics Data System (ADS)

    Al-Qaim, Fouad Fadhil; Abdullah, Md Pauzi; Othman, Mohamed Rozali

    2013-11-01

    In this work, a developed method using solid - phase extraction (SPE) followed by liquid chromatography - time of flight mass spectrometry (LC-ESI-TOF/MS) was developed and validated for quantification and confirmation of eleven pharmaceuticals with different therapeutic classes in water samples, Malaysia. These compounds are caffeine (CAF), prazosin (PRZ), enalapril (ENL), carbamazepine (CBZ), nifedipine (NFD), levonorgestrel (LNG), simvastatin (SMV), hydrochlorothiazide (HYD), gliclazide (GLIC), diclofenac-Na (DIC-Na) and mefenamic acid (MEF). LC was performed on a Dionex Ultimate 3000/LC 09115047 (USA) system. Chromatography was performed on a Thermo Scientific C18 (250 mm × 2.1 mm, i.d.: 5μm) column. Several parameters were optimised such as; mobile phase, gradient elution, collision energy and solvent elution for extraction of compounds from water. The recoveries obtained ranged from 30-148 % in river water. Five pharmaceutical compounds were detected in the surface water samples: caffeine, prazosin, enalpril, diclofenac-Na and mefenamic acid. The developed method is precise and accepted recoveries were got. In addition, this method is suitable to identify and quantify trace concentrations of pharmaceuticals in surface water.

  19. A reversed phase high performance liquid chromatography method for the determination of fumonisins B1 and B2 in food and feed using monolithic column and positive confirmation by liquid chromatography/tandem mass spectrometry.

    PubMed

    Khayoon, Wejdan Shakir; Saad, Bahruddin; Salleh, Baharuddin; Ismail, Nor Azliza; Abdul Manaf, Normaliza Hj; Abdul Latiff, Aishah

    2010-10-29

    The development of a reversed phase high performance liquid chromatography fluorescence method for the determination of the mycotoxins fumonisin B(1) and fumonisin B(2) by using silica-based monolithic column is described. The samples were first extracted using acetonitrile:water (50:50, v/v) and purified by using a C(18) solid phase extraction-based clean-up column. Then, pre-column derivatization for the analyte using ortho-phthaldialdehyde in the presence of 2-mercaptoethanol was carried out. The developed method involved optimization of mobile phase composition using methanol and phosphate buffer, injection volume, temperature and flow rate. The liquid chromatographic separation was performed using a reversed phase Chromolith(®) RP-18e column (100 mm × 4.6 mm) at 30 °C and eluted with a mobile phase of a mixture of methanol and phosphate buffer pH 3.35 (78:22, v/v) at a flow rate of 1.0 mL min(-1). The fumonisins separation was achieved in about 4 min, compared to approximately 20 min by using a C(18) particle-packed column. The fluorescence excitation and emission were at 335 nm and 440 nm, respectively. The limits of detections were 0.01-0.04 μg g(-1) fumonisin B(1) and fumonisin B(2), respectively. Good recoveries were found for spiked samples (0.1, 0.5, 1.5 μg g(-1) fumonisins B(1) and B(2)), ranging from 84.0 to 106.0% for fumonisin B(1) and from 81.0 to 103.0% for fumonisin B(2). Fifty-three samples were analyzed including 39 food and feeds and 14 inoculated corn and rice. Results show that 12.8% of the food and feed samples were contaminated with fumonisin B(1) (range, 0.01-0.51 μg g(-1)) and fumonisin B(2) (0.05 μg g(-1)). The total fumonisins in these samples however, do not exceed the legal limits established by the European Union of 0.8 μg g(-1). Of the 14 inoculated samples, 57.1% contained fumonisin B(1) (0.16-41.0 μg g(-1)) and fumonisin B(2) (range, 0.22-50.0 μg g(-1)). Positive confirmation of selected samples was carried out using liquid chromatography-tandem mass spectrometry, using triple quadrupole analyzer and operated in the multiple reaction monitoring mode. Copyright © 2010 Elsevier B.V. All rights reserved.

  20. Separation and purification of thymopentin with molecular imprinting membrane by solid phase extraction disks.

    PubMed

    Wang, Chaoli; Hu, Xiaoling; Guan, Ping; Wu, Danfeng; Qian, Liwei; Li, Ji; Song, Renyuan

    2015-01-01

    The synthesis and performance of molecularly imprinted membranes (MIMs) as a solid phase extraction packing materials for the separation and purification of thymopentin from crude samples was described. In order to increase structural selectivity and imprinting efficiency, surface-initiated ATRP and ionic liquid (1-vinyl-3-ethyl acetate imidazolium chloride) were used to prepare molecularly imprinting membranes. The results demonstrated that solid phase extraction disks stuffed by MIMs with ionic liquids as functional monomer demonstrated high isolation and purification of performance to the thymopentin. The molecular recognition of thymopentin was analyzed by using molecular modeling software. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Analysis of n-alkanes at sub microgram per liter level after direct solid phase microextraction from aqueous samples.

    PubMed

    Farajzadeh, Mirali; Hatami, Mehdi

    2002-11-01

    This work describes the application of the previously presented solid phase microextraction (SPME) fiber in direct mode for sampling of C10-C20 n-alkanes from aqueous solution. The fiber has simple composition and is constructed from activated charcoal:PVC suspension in tetrahydrofuran. When the composition of the fiber was optimized that the optimum composition was 90:10 (activated charcoal:PVC) for direct mode, whereas it was 75:25 for sampling from the headspace of aqueous samples. This fiber is completely stable in contact with water. The extraction efficiency is improved in the presence of 0.1 M NaCl. The value is between 17.8-38.5% for the first extraction, which better than the efficiency of similar commercial fibers. After seven extractions, all analytes are removed from the aqueous samples nearly 100%. Single fiber repeatability and fiber-to-fiber reproducibility are good and both are less than 13% for all studied alkanes. Finally, direct mode SPME was used in the determination of n-alkanes in the range of sub microg L(-1) without any additional preconcentration procedure. Gas chromatography along with flame ionization detection were used for separation and detection of the studied analytes.

  2. Preparation and quantification of the total phenolic products in Citrus fruit using solid-phase extraction coupled with high-performance liquid chromatography with diode array and UV detection.

    PubMed

    Zeng, Honglian; Liu, Zhenli; Zhao, Siyu; Shu, Yisong; Song, Zhiqian; Wang, Chun; Dong, Yunzhuo; Ning, Zhangchi; He, Dan; Wang, Menglei; Lu, Cheng; Liu, Yuanyan; Lu, Aiping

    2016-10-01

    Citrus fruit is an important health-promoting food that is rich in dietary phenolic metabolites. Traditional Chinese medicines, such as Zhishi and Zhiqiao, come from young and immature fruits of Citrus cultivars. The preparation of diversified bioactive phenolic products and establishment of the corresponding quality control methodology are challenging and necessary. In the current study, four types of solid-phase extraction sorbents for the enrichment and clean-up of the phenolic matrix were evaluated. A solid-phase extraction column coated with Strata-X was finally used in the procedure. Twenty phenolic compounds were selected to evaluate the extraction performances of the sorbents using high-performance liquid chromatography analysis. Under the optimized conditions, good linearities were obtained with R 2 more than 0.9996 for all analytes with LODs of 0.04-1.012 μg/g. Intra- and interday relative standard deviation values were less than 3%, and the recovery was equal to or higher than 90.02%. Compared to non-solid-phase extraction process, the content of total phenolic products was elevated 35.55-68.48% with solid-phase extraction. Finally, the developed and validated method was successfully applied to the discrimination of Zhishi samples from different species as well as Zhishi and Zhiqiao samples in different development stages. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Determination of 4-tert-octylphenol in surface water samples of Jinan in China by solid phase extraction coupled with GC-MS.

    PubMed

    Yang, Xueyu; Liu, Mingren; Wang, Zhongpeng; Li, Qian; Zhang, Zhaoliang

    2013-08-01

    Octylphenols, considered as xenoestrogens, mainly exist as 4-tert-octylphenol (OP) in aquatic environments. The high stability and accumulation of OP in aquatic systems have caused endocrine disruption. The OP in surface water in Jinan, China was analyzed by gas chromatography-mass spectrometry (GC-MS) coupled with solid phase extraction (SPE). Water samples were extracted by SPE on a cartridge system containing C-18 as sorbent. To increase sensitivity and selectivity, OP was derivatized to 4-tert-octyl-phenoxy silane. With the use of phenanthrene-d10 as internal standard, the detection limit based on signal-to-noise ratio (S/N = 3) was 0.06 ng/mL. The average recovery was from 84.67% to 109.7%. The precision of the method given as the relative standard deviations (RSD) was within the range 6.24%-12.96%. In the target water samples, the concentrations of OP were as follows: 15.88-71.24 ng/L for Jinxiuchuan Reservoir, 3.850-26.68 ng/L for the city moat, 6.930-41.56 ng/L for Daming Lake, 66.03-474.2 ng/L for Xiaoqing River, 14.66-17.72 ng/L for the Yellow River, and 10.60-26.43 ng/L for Queshan Reservoir. The Xiaoqing River was seriously polluted due to the discharge of wastewater from Jinan. Jinxiuchuan Reservoir had a higher concentration of OP compared with the Yellow River and Queshan Reservoir, which is ascribed to the surrounding human activities. These data are reported for the first time, providing strong support for the control of OP pollution in Jinan.

  4. High-performance liquid chromatography ultraviolet-photodiode array detection method for aflatoxin B1 in cattle feed supplements

    PubMed Central

    Mochamad, Lazuardi; Hermanto, Bambang

    2017-01-01

    Aim: The objective of the current study is to determine the concentration of aflatoxin B1 using high-performance liquid chromatography (HPLC) with a photodiode array (PDA) detector. Materials and Methods: Aflatoxin B1 certified reference grade from Trilogy Analytical Laboratory dissolved acetonitrile (ACN) at 10 µg/mL was using standard assessment. HPLC instruments such as ultraviolet-PDA detector used a Shimadzu LC-6AD pump with DGU-20A5 degasser, communication module-20A, and PDA detector SPD-M20A with FRC-10A fraction collector. The HPLC was set isocratic method at 354 nm with a reverse-phase ODS C18 column (LiChrospher® 100 RP-18; diameter, 5 µm) under a 20°C controlled column chamber. Rheodyne® sample loops were performed in 20 µL capacities. The mobile phase was performed at fraction 63:26:11 H2O: methanol:ACN at pH 6.8. A total of 1 kg of feed contained 10% bread crumbs and 30% concentrated, 40% forage, and 20% soybean dregs were using commercials samples. Samples were extracted by ACN and separated with solid phase extraction ODS 1 mL than elution with mobile phase to collect at drying samples performed. The samples were ready to use after added 1 mL mobile phase than injected into the system of HPLC. Results: We found that the retention time of aflatoxin B1 was approximately 10.858 min. Linearity of 0.01-0.08 µg/mL aflatoxin B1 dissolved in mobile phase was obtained at R2=0.9. These results demonstrate that these methods can be used to analyze aflatoxin B1 and gain 89-99% recovery. The limit of detection of this assay was obtained at 3.5 × 10−6 µg/mL. Conclusion: This method was easy to apply and suitable to analyzing at small concentrations of aflatoxin B1 in formulated product of feed cattle. PMID:28919686

  5. Selective extraction and separation of oxymatrine from Sophora flavescens Ait. extract by silica-confined ionic liquid.

    PubMed

    Bi, Wentao; Tian, Minglei; Row, Kyung Ho

    2012-01-01

    This study highlighted the application of a two-stepped extraction method for extraction and separation of oxymatrine from Sophora flavescens Ait. extract by utilizing silica-confined ionic liquids as sorbent. The optimized silica-confined ionic liquid was firstly mixed with plant extract to adsorb oxymatrine. Simultaneously, some interference, such as matrine, was removed. The obtained suspension was then added to a cartridge for solid phase extraction. Through these two steps, target compound was adequately separated from interferences with 93.4% recovery. In comparison with traditional solid phase extraction, this method accelerates loading and reduces the use of organic solvents during washing. Moreover, the optimization of loading volume was simplified as optimization of solid/liquid ratio. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. Synthesis of a stationary phase based on silica modified with branched octadecyl groups by Michael addition and photoinduced thiol-yne click chemistry for the separation of basic compounds.

    PubMed

    Huang, Guang; Ou, Junjie; Wang, Hongwei; Ji, Yongsheng; Wan, Hao; Zhang, Zhang; Peng, Xiaojun; Zou, Hanfa

    2016-04-01

    A novel silica-based stationary phase with branched octadecyl groups was prepared by the sequential employment of the Michael addition reaction and photoinduced thiol-yne click chemistry with 3-aminopropyl-functionalized silica microspheres as the initial material. The resulting stationary phase denoted as SiO2 -N(C18)4 was characterized by elemental analysis, FTIR spectroscopy and Raman spectroscopy, demonstrating the existence of branched octadecyl groups in silica microspheres. The separations of benzene homologous compounds, acid compounds and amine analogues were conducted, demonstrating mixed-mode separation mechanism on SiO2 -N(C18)4 . Baseline separation of basic drugs mixture was acquired with the mobile phase of acetonitrile/H2 O (5%, v/v). SiO2 -N(C18)4 was further applied to separate Corydalis yanhusuo Wang water extracts, and more baseline separation peaks were obtained for SiO2 -N(C18)4 than those on Atlantis dC18 column. It can be expected that this new silica-based stationary phase will exhibit great potential in the analysis of basic compounds. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Platform construction and extraction mechanism study of magnetic mixed hemimicelles solid-phase extraction

    NASA Astrophysics Data System (ADS)

    Xiao, Deli; Zhang, Chan; He, Jia; Zeng, Rong; Chen, Rong; He, Hua

    2016-12-01

    Simple, accurate and high-throughput pretreatment method would facilitate large-scale studies of trace analysis in complex samples. Magnetic mixed hemimicelles solid-phase extraction has the power to become a key pretreatment method in biological, environmental and clinical research. However, lacking of experimental predictability and unsharpness of extraction mechanism limit the development of this promising method. Herein, this work tries to establish theoretical-based experimental designs for extraction of trace analytes from complex samples using magnetic mixed hemimicelles solid-phase extraction. We selected three categories and six sub-types of compounds for systematic comparative study of extraction mechanism, and comprehensively illustrated the roles of different force (hydrophobic interaction, π-π stacking interactions, hydrogen-bonding interaction, electrostatic interaction) for the first time. What’s more, the application guidelines for supporting materials, surfactants and sample matrix were also summarized. The extraction mechanism and platform established in the study render its future promising for foreseeable and efficient pretreatment under theoretical based experimental design for trace analytes from environmental, biological and clinical samples.

  8. Simultaneous determination of kasugamycin and validamycin-A residues in cereals by consecutive solid-phase extraction combined with liquid chromatography-tandem mass spectrometry.

    PubMed

    Zhang, Hong; Wang, Chenchen; Li, Huidong; Nie, Yan; Fang, Liping; Chen, Zilei

    2018-03-01

    Two polar aminoglycosides, kasugamycin and validamycin-A, were determined in cereals (brown rice, wheat and corn) by high-performance liquid chromatography-tandem mass spectrometry. The analytes were extracted from samples using methanol and water (70:30, v/v) at pH 5.5, purified using both a hydrophilic-hydrophobic-balanced cartridge and a strong cation-exchange cartridge, and then analysed using multiple reaction monitoring in positive electrospray ionisation mode with a special ReproSil 100 C 18 high-performance liquid chromatography column. This newly proposed method yielded good sensitivity and excellent chromatographic performance. The limits of quantification for kasugamycin and validamycin-A were 4.1 µg/kg and 1.0 µg/kg, respectively. The recoveries for both compounds at three fortification levels (4, 100 and 500 µg/kg for kasugamycin; 1, 10 and 100 µg/kg for validamycin-A) ranged from 75% to 110%, and the relative standard deviations were below 15%.

  9. Validation Study on a Rapid Method for Simultaneous Determination of Pesticide Residues in Vegetables and Fruits by LC-MS/MS.

    PubMed

    Sato, Tamaki; Miyamoto, Iori; Uemura, Masako; Nakatani, Tadashi; Kakutani, Naoya; Yamano, Tetsuo

    2016-01-01

    A validation study was carried out on a rapid method for the simultaneous determination of pesticide residues in vegetables and fruits by LC-MS/MS. Preparation of the test solution was performed by a solid-phase extraction technique with QuEChERS (STQ method). Pesticide residues were extracted with acetonitrile using a homogenizer, followed by salting-out and dehydration at the same time. The acetonitrile layer was purified with C18 and PSA mini-columns. The method was assessed for 130 pesticide residues in 14 kinds of vegetables and fruits at the concentration level of 0.01 μg/g according to the method validation guideline of the Ministry of Health, Labour and Welfare of Japan. As a result 75 to 120 pesticide residues were determined satisfactorily in the tested samples. Thus, this method could be useful for a rapid and simultaneous determination of multi-class pesticide residues in various vegetables and fruits.

  10. Magnetic dispersive solid-phase extraction based on modified magnetic nanoparticles for the detection of cocaine and cocaine metabolites in human urine by high-performance liquid chromatography-mass spectrometry.

    PubMed

    Yang, Feiyu; Zou, Yun; Ni, Chunfang; Wang, Rong; Wu, Min; Liang, Chen; Zhang, Jiabin; Yuan, Xiaoliang; Liu, Wenbin

    2017-11-01

    An easy-to-handle magnetic dispersive solid-phase extraction procedure was developed for preconcentration and extraction of cocaine and cocaine metabolites in human urine. Divinyl benzene and vinyl pyrrolidone functionalized silanized Fe 3 O 4 nanoparticles were synthesized and used as adsorbents in this procedure. Scanning electron microscopy, vibrating sample magnetometry, and infrared spectroscopy were employed to characterize the modified adsorbents. A high-performance liquid chromatography with mass spectrometry method for determination of cocaine and its metabolites in human urine sample has been developed with pretreatment of the samples by magnetic dispersive solid-phase extraction. The obtained results demonstrated the higher extraction capacity of the prepared nanoparticles with recoveries between 75.1 to 105.7% and correlation coefficients higher than 0.9971. The limits of detection for the cocaine and cocaine metabolites were 0.09-1.10 ng/mL. The proposed magnetic dispersive solid-phase extraction method provided a rapid, environmentally friendly and magnetic stuff recyclable approach and it was confirmed that the prepared adsorbents material was a kind of highly effective extraction materials for the trace cocaine and cocaine metabolites analyses in human urine. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Determination of haloacetic acids in water using layered double hydroxides as a sorbent in dispersive solid-phase extraction followed by liquid chromatography with tandem mass spectrometry.

    PubMed

    Alsharaa, Abdulnaser; Sajid, Muhammad; Basheer, Chanbasha; Alhooshani, Khalid; Lee, Hian Kee

    2016-09-01

    In the present study, highly efficient and simple dispersive solid-phase extraction procedure for the determination of haloacetic acids in water samples has been established. Three different types of layered double hydroxides were synthesized and used as a sorbent in dispersive solid-phase extraction. Due to the interesting behavior of layered double hydroxides in an acidic medium (pH˂4), the analyte elution step was not needed; the layered double hydroxides are simply dissolved in acid immediately after extraction to release the analytes which are then directly introduced into a liquid chromatography with tandem mass spectrometry system for analysis. Several dispersive solid-phase extraction parameters were optimized to increase the extraction efficiency of haloacetic acids such as temperature, extraction time and pH. Under optimum conditions, good linearity was achieved over the concentration range of 0.05-100 μg/L with detection limits in the range of 0.006-0.05 μg/L. The relative standard deviations were 0.33-3.64% (n = 6). The proposed method was applied to different water samples collected from a drinking water plant to determine the concentrations of haloacetic acids. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Mycoestrogen determination in cow milk: Magnetic solid-phase extraction followed by liquid chromatography and tandem mass spectrometry analysis.

    PubMed

    Capriotti, Anna Laura; Cavaliere, Chiara; Foglia, Patrizia; La Barbera, Giorgia; Samperi, Roberto; Ventura, Salvatore; Laganà, Aldo

    2016-12-01

    Recently, magnetic solid-phase extraction has gained interest because it presents various operational advantages over classical solid-phase extraction. Furthermore, magnetic nanoparticles are easy to prepare, and various materials can be used in their synthesis. In the literature, there are only few studies on the determination of mycoestrogens in milk, although their carryover in milk has occurred. In this work, we wanted to develop the first (to the best of our knowledge) magnetic solid-phase extraction protocol for six mycoestrogens from milk, followed by liquid chromatography and tandem mass spectrometry analysis. Magnetic graphitized carbon black was chosen as the adsorbent, as this carbonaceous material, which is very different from the most diffuse graphene and carbon nanotubes, had already shown selectivity towards estrogenic compounds in milk. The graphitized carbon black was decorated with Fe 3 O 4 , which was confirmed by the characterization analyses. A milk deproteinization step was avoided, using only a suitable dilution in phosphate buffer as sample pretreatment. The overall process efficiency ranged between 52 and 102%, whereas the matrix effect considered as signal suppression was below 33% for all the analytes even at the lowest spiking level. The obtained method limits of quantification were below those of other published methods that employ classical solid-phase extraction protocols. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Bioanalytical LC-MS/MS method validation for plasma determination of topiramate in healthy Indian volunteers.

    PubMed

    Goswami, Dipanjan; Kumar, Ajay; Khuroo, Arshad H; Monif, Tausif; Rab, Shamsur

    2009-11-01

    A LC-MS/MS method for plasma topiramate analysis is delineated involving least number of healthy volunteers. Topiramate and amlodipine internal standard (IS) were extracted by simple centrifuge-coupled solid-phase extraction and reverse-phase chromatographic separation was performed on an Ascentis C(18) column. Turbo-spray negative-ion mode multiple-reaction monitoring was selected for mass pair detection at m/z 338.3 --> 78.0 and m/z 407.3 --> 295.5 for analyte and IS respectively. The method showed a dynamic linearity range from 10.4 to 2045.0 ng/mL, lower limit of quantitation achieved at 10.4 ng/mL and finally a mass spectrometric total run time of within 2.5 min for human sample analysis. Bioequivalence was assessed successfully using this fully validated method on 16 fasted Indian male subjects with 25 mg topiramate tablet administration. An appropriate study design describes plasma samples collection up to 216 h post dose in two periods, separated by a 28 day washout period. The challenge of half-life matching for test and reference drug was achieved with 73.43 +/- 9.68 and 73.06 +/- 14.03 h, respectively, and intra-subject coefficient of variation achieved within 11% for AUCs and C(max) evaluated by non-compartmental pharmacokinetic analysis. The results of LCMS topiramate complete method validation supported by pharmacokinetic study have not been published before, and are presented and discussed for the first time in this article. Copyright (c) 2009 John Wiley & Sons, Ltd.

  14. Development of clinical dosage forms for a poorly water-soluble drug II: formulation and characterization of a novel solid microemulsion preconcentrate system for oral delivery of a poorly water-soluble drug.

    PubMed

    Li, Ping; Hynes, Sara R; Haefele, Thomas F; Pudipeddi, Madhu; Royce, Alan E; Serajuddin, Abu T M

    2009-05-01

    The solution of a poorly water-soluble drug in a liquid lipid-surfactant mixture, which served as a microemulsion preconcentrate, was converted into a solid form by incorporating it in a solid polyethylene glycol (PEG) matrix. The solid microemulsion preconcentrates thus formed consisted of Capmul PG8 (propylene glycol monocaprylate) as oil, Cremophor EL (polyoxyl 35 castor oil) as surfactant, and hydrophilic polymer PEG 3350 as solid matrix. The drug (aqueous solubility: 0.17 microg/mL at pH 1-8 and 25 degrees C) was dissolved in a melt of the mixture at 65-70 degrees C and then the hot solution was filled into hard gelatin capsules; the liquid gradually solidified upon cooling below 55 degrees C. The solid system was characterized by differential scanning calorimetry (DSC), scanning electron microscopy (SEM), confocal Raman microscopy (CRM), and the dispersion testing in water. It was confirmed that a solid microemulsion preconcentrate is a two-phase system, where clusters of crystalline PEG 3350 formed the solid structure (m.p. 55-60 degrees C) and the liquid microemulsion preconcentrate dispersed in between PEG 3350 crystals as a separate phase. The drug remained dissolved in the liquid phase. In vitro release testing showed that the preconcentrate dispersed readily in water forming a microemulsion with the drug dissolved in the oil particles (<150 nm) and the presence of PEG 3350 did not interfere with the process of self-microemulsification.

  15. Streamlined sample cleanup using combined dispersive solid-phase extraction and in-vial filtration for analysis of pesticides and environmental pollutants in shrimp

    USDA-ARS?s Scientific Manuscript database

    A new method of sample preparation was developed and is reported for the first time. The approach combines in-vial filtration with dispersive solid-phase extraction (d-SPE) in a fast and convenient cleanup of QuEChERS (quick, easy, cheap, effective, rugged, and safe) extracts. The method was appli...

  16. COMPARISON OF TWO DIFFERENT SOLID PHASE EXTRACTION/LARGE VOLUME INJECTION PROCEDURES FOR METHOD 8270

    EPA Science Inventory

    Two solid phase (SPE) and one traditional continuous liquid-liquid extraction method are compared for analysis of Method 8270 SVOCs. Productivity parameters include data quality, sample volume, analysis time and solvent waste.

    One SPE system, unique in the U.S., uses aut...

  17. Analysis of ecologically relevant pharmaceuticals in wastewater and surface water using selective solid phase extraction and UPLC/MS/MS

    EPA Science Inventory

    A rapid and sensitive method has been developed for the analysis of 48 human prescription active pharmaceutical ingredients (APIs) and 6 metabolites of interest, utilizing selective solid-phase extraction (SPE) and ultra performance liquid chromatography in combination with tripl...

  18. 40 CFR 141.40 - Monitoring requirements for unregulated contaminants.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... monitoring to be completed Reserved i Reserved i Reserved i Reserved i Reserved i Reserved i Column headings... Pesticides and Flame Retardants in Drinking Water by Solid Phase Extraction and Capillary Column Gas... Water by Solid Phase Extraction and Capillary Column Gas Chromatography/Mass Spectrometry (GC/MS...

  19. Development of a Solid Phase Extraction Method for Agricultural Pesticides in Large-Volume Water Samples

    EPA Science Inventory

    An analytical method using solid phase extraction (SPE) and analysis by gas chromatography/mass spectrometry (GC/MS) was developed for the trace determination of a variety of agricultural pesticides and selected transformation products in large-volume high-elevation lake water sa...

  20. AUTOMATED SOLID PHASE EXTRACTION GC/MS FOR ANALYSIS OF SEMIVOLATILES IN WATER AND SEDIMENTS

    EPA Science Inventory

    Data is presented on the development of a new automated system combining solid phase extraction (SPE) with GC/MS spectrometry for the single-run analysis of water samples containing a broad range of organic compounds. The system uses commercially available automated in-line sampl...

Top