Sample records for cad computer-aided design

  1. Computer-aided design development transition for IPAD environment

    NASA Technical Reports Server (NTRS)

    Owens, H. G.; Mock, W. D.; Mitchell, J. C.

    1980-01-01

    The relationship of federally sponsored computer-aided design/computer-aided manufacturing (CAD/CAM) programs to the aircraft life cycle design process, an overview of NAAD'S CAD development program, an evaluation of the CAD design process, a discussion of the current computing environment within which NAAD is developing its CAD system, some of the advantages/disadvantages of the NAAD-IPAD approach, and CAD developments during transition into the IPAD system are discussed.

  2. Software Tools for Shipbuilding Productivity

    DTIC Science & Technology

    1984-12-01

    shipbuilding, is that design, manufacturing and robotic technology applications to shipbuilding have been proven. all aspects of shipbuilding is now a task...technical information about the process of Computer Aided Design (CAD) and Computer Aided Manufacturing (CAM) effectively has been a problem of serious and...Design (CAD) 3.4.1 CAD System Components 3.4.2 CAD System Benefits 3.4.3 New and Future CAD Technologies Computer Aided Manufacturing (CAM) 3.5.1 CAM

  3. Creation of Anatomically Accurate Computer-Aided Design (CAD) Solid Models from Medical Images

    NASA Technical Reports Server (NTRS)

    Stewart, John E.; Graham, R. Scott; Samareh, Jamshid A.; Oberlander, Eric J.; Broaddus, William C.

    1999-01-01

    Most surgical instrumentation and implants used in the world today are designed with sophisticated Computer-Aided Design (CAD)/Computer-Aided Manufacturing (CAM) software. This software automates the mechanical development of a product from its conceptual design through manufacturing. CAD software also provides a means of manipulating solid models prior to Finite Element Modeling (FEM). Few surgical products are designed in conjunction with accurate CAD models of human anatomy because of the difficulty with which these models are created. We have developed a novel technique that creates anatomically accurate, patient specific CAD solids from medical images in a matter of minutes.

  4. CAD/CAE Integration Enhanced by New CAD Services Standard

    NASA Technical Reports Server (NTRS)

    Claus, Russell W.

    2002-01-01

    A Government-industry team led by the NASA Glenn Research Center has developed a computer interface standard for accessing data from computer-aided design (CAD) systems. The Object Management Group, an international computer standards organization, has adopted this CAD services standard. The new standard allows software (e.g., computer-aided engineering (CAE) and computer-aided manufacturing software to access multiple CAD systems through one programming interface. The interface is built on top of a distributed computing system called the Common Object Request Broker Architecture (CORBA). CORBA allows the CAD services software to operate in a distributed, heterogeneous computing environment.

  5. Incorporation of CAD/CAM Restoration Into Navy Dentistry

    DTIC Science & Technology

    2017-09-26

    CAD/CAM Computer-aided design /Computer-assisted manufacturing CDT Common Dental Terminology DENCAS Dental Common Access System DTF Dental...to reduce avoidable dental emergencies for deployed sailors and marines. Dental Computer-aided design /Computer-assisted manufacturing (CAD/CAM...report will review and evaluate the placement rate by Navy dentists of digitally fabricated in-office ceramic restorations compared to traditional direct

  6. Computer Aided Design in Engineering Education.

    ERIC Educational Resources Information Center

    Gobin, R.

    1986-01-01

    Discusses the use of Computer Aided Design (CAD) and Computer Aided Manufacturing (CAM) systems in an undergraduate engineering education program. Provides a rationale for CAD/CAM use in the already existing engineering program. Describes the methods used in choosing the systems, some initial results, and warnings for first-time users. (TW)

  7. [Development of computer aided forming techniques in manufacturing scaffolds for bone tissue engineering].

    PubMed

    Wei, Xuelei; Dong, Fuhui

    2011-12-01

    To review recent advance in the research and application of computer aided forming techniques for constructing bone tissue engineering scaffolds. The literature concerning computer aided forming techniques for constructing bone tissue engineering scaffolds in recent years was reviewed extensively and summarized. Several studies over last decade have focused on computer aided forming techniques for bone scaffold construction using various scaffold materials, which is based on computer aided design (CAD) and bone scaffold rapid prototyping (RP). CAD include medical CAD, STL, and reverse design. Reverse design can fully simulate normal bone tissue and could be very useful for the CAD. RP techniques include fused deposition modeling, three dimensional printing, selected laser sintering, three dimensional bioplotting, and low-temperature deposition manufacturing. These techniques provide a new way to construct bone tissue engineering scaffolds with complex internal structures. With rapid development of molding and forming techniques, computer aided forming techniques are expected to provide ideal bone tissue engineering scaffolds.

  8. Teaching Computer-Aided Design of Fluid Flow and Heat Transfer Engineering Equipment.

    ERIC Educational Resources Information Center

    Gosman, A. D.; And Others

    1979-01-01

    Describes a teaching program for fluid mechanics and heat transfer which contains both computer aided learning (CAL) and computer aided design (CAD) components and argues that the understanding of the physical and numerical modeling taught in the CAL course is essential to the proper implementation of CAD. (Author/CMV)

  9. Computer Aided Design in FE. Some Suggestions on the Inclusion of CAD Topics in Mechanical Engineering Courses. An Occasional Paper.

    ERIC Educational Resources Information Center

    Ingham, P. C.

    This report investigates the feasibility of including computer aided design (CAD) materials in engineering courses. Section 1 briefly discusses the inevitability of CAD being adopted widely by British industry and the consequent need for its inclusion in engineering syllabi at all levels. A short description of what is meant by CAD follows in…

  10. [Key points for esthetic rehabilitation of anterior teeth using chair-side computer aided design and computer aided manufacture technique].

    PubMed

    Yang, J; Feng, H L

    2018-04-09

    With the rapid development of the chair-side computer aided design and computer aided manufacture (CAD/CAM) technology, its accuracy and operability of have been greatly improved in recent years. Chair-side CAD/CAM system may produce all kinds of indirect restorations, and has the advantages of rapid, accurate and stable production. It has become the future development direction of Stomatology. This paper describes the clinical application of the chair-side CAD/CAM technology for anterior aesthetic restorations from the aspects of shade and shape.

  11. Computer-Aided Design in Further Education.

    ERIC Educational Resources Information Center

    Ingham, Peter, Ed.

    This publication updates the 1982 occasional paper that was intended to foster staff awareness and assist colleges in Great Britain considering the use of computer-aided design (CAD) material in engineering courses. The paper begins by defining CAD and its place in the Integrated Business System with a brief discussion of the effect of CAD on the…

  12. Integrated Computer-Aided Drafting Instruction (ICADI).

    ERIC Educational Resources Information Center

    Chen, C. Y.; McCampbell, David H.

    Until recently, computer-aided drafting and design (CAD) systems were almost exclusively operated on mainframes or minicomputers and their cost prohibited many schools from offering CAD instruction. Today, many powerful personal computers are capable of performing the high-speed calculation and analysis required by the CAD application; however,…

  13. An Analysis of Computer Aided Design (CAD) Packages Used at MSFC for the Recent Initiative to Integrate Engineering Activities

    NASA Technical Reports Server (NTRS)

    Smith, Leigh M.; Parker, Nelson C. (Technical Monitor)

    2002-01-01

    This paper analyzes the use of Computer Aided Design (CAD) packages at NASA's Marshall Space Flight Center (MSFC). It examines the effectiveness of recent efforts to standardize CAD practices across MSFC engineering activities. An assessment of the roles played by management, designers, analysts, and manufacturers in this initiative will be explored. Finally, solutions are presented for better integration of CAD across MSFC in the future.

  14. CAD for small hydro projects

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bishop, N.A. Jr.

    1994-04-01

    Over the past decade, computer-aided design (CAD) has become a practical and economical design tool. Today, specifying CAD hardware and software is relatively easy once you know what the design requirements are. But finding experienced CAD professionals is often more difficult. Most CAD users have only two or three years of design experience; more experienced design personnel are frequently not CAD literate. However, effective use of CAD can be the key to lowering design costs and improving design quality--a quest familiar to every manager and designer. By emphasizing computer-aided design literacy at all levels of the firm, a Canadian joint-venturemore » company that specializes in engineering small hydroelectric projects has cut costs, become more productive and improved design quality. This article describes how they did it.« less

  15. Web-Based Learning in the Computer-Aided Design Curriculum.

    ERIC Educational Resources Information Center

    Sung, Wen-Tsai; Ou, S. C.

    2002-01-01

    Applies principles of constructivism and virtual reality (VR) to computer-aided design (CAD) curriculum, particularly engineering, by integrating network, VR and CAD technologies into a Web-based learning environment that expands traditional two-dimensional computer graphics into a three-dimensional real-time simulation that enhances user…

  16. A Novel Computer-Aided Design/Computer-Assisted Manufacture Method for One-Piece Removable Partial Denture and Evaluation of Fit.

    PubMed

    Ye, Hongqiang; Li, Xinxin; Wang, Guanbo; Kang, Jing; Liu, Yushu; Sun, Yuchun; Zhou, Yongsheng

    2018-02-15

    To investigate a computer-aided design/computer-aided manufacturing (CAD/CAM) process for producing one-piece removable partial dentures (RPDs) and to evaluate their fits in vitro. A total of 15 one-piece RPDs were designed using dental CAD and reverse engineering software and then fabricated with polyetheretherketone (PEEK) using CAM. The gaps between RPDs and casts were measured and compared with traditional cast framework RPDs. Gaps were lower for one-piece PEEK RPDs compared to traditional RPDs. One-piece RPDs can be manufactured by CAD/CAM, and their fits were better than those of traditional RPDs.

  17. Integrated computer-aided design using minicomputers

    NASA Technical Reports Server (NTRS)

    Storaasli, O. O.

    1980-01-01

    Computer-Aided Design/Computer-Aided Manufacturing (CAD/CAM), a highly interactive software, has been implemented on minicomputers at the NASA Langley Research Center. CAD/CAM software integrates many formerly fragmented programs and procedures into one cohesive system; it also includes finite element modeling and analysis, and has been interfaced via a computer network to a relational data base management system and offline plotting devices on mainframe computers. The CAD/CAM software system requires interactive graphics terminals operating at a minimum of 4800 bits/sec transfer rate to a computer. The system is portable and introduces 'interactive graphics', which permits the creation and modification of models interactively. The CAD/CAM system has already produced designs for a large area space platform, a national transonic facility fan blade, and a laminar flow control wind tunnel model. Besides the design/drafting element analysis capability, CAD/CAM provides options to produce an automatic program tooling code to drive a numerically controlled (N/C) machine. Reductions in time for design, engineering, drawing, finite element modeling, and N/C machining will benefit productivity through reduced costs, fewer errors, and a wider range of configuration.

  18. Challenges facing developers of CAD/CAM models that seek to predict human working postures

    NASA Astrophysics Data System (ADS)

    Wiker, Steven F.

    2005-11-01

    This paper outlines the need for development of human posture prediction models for Computer Aided Design (CAD) and Computer Aided Manufacturing (CAM) design applications in product, facility and work design. Challenges facing developers of posture prediction algorithms are presented and discussed.

  19. Adhesive Bonding to Computer-aided Design/ Computer-aided Manufacturing Esthetic Dental Materials: An Overview.

    PubMed

    Awad, Mohamed Moustafa; Alqahtani, H; Al-Mudahi, A; Murayshed, M S; Alrahlah, A; Bhandi, Shilpa H

    2017-07-01

    To review the adhesive bonding to different computer-aided design/computer-aided manufacturing (CAD/CAM) esthetic restorative materials. The use of CAD/CAM esthetic restorative materials has gained popularity in recent years. Several CAD/ CAM esthetic restorative materials are commercially available. Adhesive bonding is a major determinant of success of CAD/ CAM restorations. Review result: An account of the currently available bonding strategies are discussed with their rationale in various CAD/ CAM materials. Different surface treatment methods as well as adhesion promoters can be used to achieve reliable bonding of CAD/CAM restorative materials. Selection of bonding strategy to such material is determined based on its composition. Further evidence is required to evaluate the effect of new surface treatment methods, such as nonthermal atmospheric plasma and self-etching ceramic primer on bonding to different dental ceramics. An understanding of the currently available bonding strategies to CA/CAM materials can help the clinician to select the most indicated system for each category of materials.

  20. Recent development on computer aided tissue engineering--a review.

    PubMed

    Sun, Wei; Lal, Pallavi

    2002-02-01

    The utilization of computer-aided technologies in tissue engineering has evolved in the development of a new field of computer-aided tissue engineering (CATE). This article reviews recent development and application of enabling computer technology, imaging technology, computer-aided design and computer-aided manufacturing (CAD and CAM), and rapid prototyping (RP) technology in tissue engineering, particularly, in computer-aided tissue anatomical modeling, three-dimensional (3-D) anatomy visualization and 3-D reconstruction, CAD-based anatomical modeling, computer-aided tissue classification, computer-aided tissue implantation and prototype modeling assisted surgical planning and reconstruction.

  1. Classification of Computer-Aided Design-Computer-Aided Manufacturing Applications for the Reconstruction of Cranio-Maxillo-Facial Defects.

    PubMed

    Wauters, Lauri D J; Miguel-Moragas, Joan San; Mommaerts, Maurice Y

    2015-11-01

    To gain insight into the methodology of different computer-aided design-computer-aided manufacturing (CAD-CAM) applications for the reconstruction of cranio-maxillo-facial (CMF) defects. We reviewed and analyzed the available literature pertaining to CAD-CAM for use in CMF reconstruction. We proposed a classification system of the techniques of implant and cutting, drilling, and/or guiding template design and manufacturing. The system consisted of 4 classes (I-IV). These classes combine techniques used for both the implant and template to most accurately describe the methodology used. Our classification system can be widely applied. It should facilitate communication and immediate understanding of the methodology of CAD-CAM applications for the reconstruction of CMF defects.

  2. Computer-Aided Apparel Design in University Curricula.

    ERIC Educational Resources Information Center

    Belleau, Bonnie D.; Bourgeois, Elva B.

    1991-01-01

    As computer-assisted design (CAD) become an integral part of the fashion industry, universities must integrate CAD into the apparel curriculum. Louisiana State University's curriculum enables students to collaborate in CAD problem solving with industry personnel. (SK)

  3. The use of computer-aided design/manufacturing (CAD/CAM) technology to aid in the reconstruction of congenitally deficient pediatric mandibles: A case series.

    PubMed

    Gougoutas, Alexander J; Bastidas, Nicholas; Bartlett, Scott P; Jackson, Oksana

    2015-12-01

    Microvascular reconstruction of the pediatric mandible, particularly when necessitated by severe, congenital hypoplasia, presents a formidable challenge. Complex cases, however, may be simplified by computer-aided design/computer-aided manufacturing (CAD/CAM) assisted surgical planning. This series represents the senior authors' preliminary experiences with CAD/CAM assisted, microvascular reconstruction of the pediatric mandible. Presented are two patients with hemifacial/bifacial microsomia, both with profound mandibular hypoplasia, who underwent CAD/CAM assisted reconstruction of their mandibles with vascularized fibula flaps. Surgical techniques, CAD/CAM routines employed, complications, and long-term outcomes are reported. Successful mandibular reconstructions were achieved in both patients with centralization of their native mandibles and augmentation of deficient mandibular subunits. No long-term complications were observed. CAD/CAM technology can be utilized in pediatric mandibular reconstruction, and is particularly beneficial in cases of profound, congenital hypoplasia requiring extensive, multi-planar, bony reconstructions. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  4. [Clinical skills and outcomes of chair-side computer aided design and computer aided manufacture system].

    PubMed

    Yu, Q

    2018-04-09

    Computer aided design and computer aided manufacture (CAD/CAM) technology is a kind of oral digital system which is applied to clinical diagnosis and treatment. It overturns the traditional pattern, and provides a solution to restore defect tooth quickly and efficiently. In this paper we mainly discuss the clinical skills of chair-side CAD/CAM system, including tooth preparation, digital impression, the three-dimensional design of prosthesis, numerical control machining, clinical bonding and so on, and review the outcomes of several common kinds of materials at the same time.

  5. Electronic Computer Aided Design. Its Application in FE.

    ERIC Educational Resources Information Center

    Further Education Unit, London (England).

    A study was conducted at the Electronics Industrial Unit at the Dorset Institute of Higher Education to investigate the feasibility of incorporating computer-aided design (CAD) in electrical and electronic courses. The aim was to investigate the application of CAD to electrical and electronic systems; the extent to which industrial developments…

  6. An esthetics rehabilitation with computer-aided design/ computer-aided manufacturing technology.

    PubMed

    Mazaro, Josá Vitor Quinelli; de Mello, Caroline Cantieri; Zavanelli, Adriana Cristina; Santiago, Joel Ferreira; Amoroso, Andressa Paschoal; Pellizzer, Eduardo Piza

    2014-07-01

    This paper describes a case of a rehabilitation involving Computer Aided Design/Computer Aided Manufacturing (CAD-CAM) system in implant supported and dental supported prostheses using zirconia as framework. The CAD-CAM technology has developed considerably over last few years, becoming a reality in dental practice. Among the widely used systems are the systems based on zirconia which demonstrate important physical and mechanical properties of high strength, adequate fracture toughness, biocompatibility and esthetics, and are indicated for unitary prosthetic restorations and posterior and anterior framework. All the modeling was performed by using CAD-CAM system and prostheses were cemented using resin cement best suited for each situation. The rehabilitation of the maxillary arch using zirconia framework demonstrated satisfactory esthetic and functional results after a 12-month control and revealed no biological and technical complications. This article shows the important of use technology CAD/CAM in the manufacture of dental prosthesis and implant-supported.

  7. Dental students' preferences and performance in crown design: conventional wax-added versus CAD.

    PubMed

    Douglas, R Duane; Hopp, Christa D; Augustin, Marcus A

    2014-12-01

    The purpose of this study was to evaluate dental students' perceptions of traditional waxing vs. computer-aided crown design and to determine the effectiveness of either technique through comparative grading of the final products. On one of twoidentical tooth preparations, second-year students at one dental school fabricated a wax pattern for a full contour crown; on the second tooth preparation, the same students designed and fabricated an all-ceramic crown using computer-aided design (CAD) and computer-aided manufacturing (CAM) technology. Projects were graded for occlusion and anatomic form by three faculty members. On completion of the projects, 100 percent of the students (n=50) completed an eight-question, five-point Likert scalesurvey, designed to assess their perceptions of and learning associated with the two design techniques. The average grades for the crown design projects were 78.3 (CAD) and 79.1 (wax design). The mean numbers of occlusal contacts were 3.8 (CAD) and 2.9(wax design), which was significantly higher for CAD (p=0.02). The survey results indicated that students enjoyed designing afull contour crown using CAD as compared to using conventional wax techniques and spent less time designing the crown using CAD. From a learning perspective, students felt that they learned more about position and the size/strength of occlusal contacts using CAD. However, students recognized that CAD technology has limits in terms of representing anatomic contours and excursive occlusion compared to conventional wax techniques. The results suggest that crown design using CAD could be considered as an adjunct to conventional wax-added techniques in preclinical fixed prosthodontic curricula.

  8. A Review of Developments in Computer-Based Systems to Image Teeth and Produce Dental Restorations

    PubMed Central

    Rekow, E. Dianne; Erdman, Arthur G.; Speidel, T. Michael

    1987-01-01

    Computer-aided design and manufacturing (CAD/CAM) make it possible to automate the creation of dental restorations. Currently practiced techniques are described. Three automated systems currently under development are described and compared. Advances in computer-aided design and computer-aided manufacturing (CAD/CAM) provide a new option for dentistry, creating an alternative technique for producing dental restorations. It is possible to create dental restorations that are automatically produced and meet or exceed current requirements for fit and occlusion.

  9. [Research and application of computer-aided technology in restoration of maxillary defect].

    PubMed

    Cheng, Xiaosheng; Liao, Wenhe; Hu, Qingang; Wang, Qian; Dai, Ning

    2008-08-01

    This paper presents a new method of designing restoration model of maxillectomy defect through Computer aided technology. Firstly, 3D maxillectomy triangle mesh model is constructed from Helical CT data. Secondly, the triangle mesh model is transformed into initial computer-aided design (CAD) model of maxillectomy through reverse engineering software. Thirdly, the 3D virtual restoration model of maxillary defect is obtained after designing and adjusting the initial CAD model through CAD software according to the patient's practical condition. Therefore, the 3D virtual restoration can be fitted very well with the broken part of maxilla. The exported design data can be manufactured using rapid prototyping technology and foundry technology. Finally, the result proved that this method is effective and feasible.

  10. A Multidisciplinary Research Team Approach to Computer-Aided Drafting (CAD) System Selection. Final Report.

    ERIC Educational Resources Information Center

    Franken, Ken; And Others

    A multidisciplinary research team was assembled to review existing computer-aided drafting (CAD) systems for the purpose of enabling staff in the Design Drafting Department at Linn Technical College (Missouri) to select the best system out of the many CAD systems in existence. During the initial stage of the evaluation project, researchers…

  11. Evolution of Geometric Sensitivity Derivatives from Computer Aided Design Models

    NASA Technical Reports Server (NTRS)

    Jones, William T.; Lazzara, David; Haimes, Robert

    2010-01-01

    The generation of design parameter sensitivity derivatives is required for gradient-based optimization. Such sensitivity derivatives are elusive at best when working with geometry defined within the solid modeling context of Computer-Aided Design (CAD) systems. Solid modeling CAD systems are often proprietary and always complex, thereby necessitating ad hoc procedures to infer parameter sensitivity. A new perspective is presented that makes direct use of the hierarchical associativity of CAD features to trace their evolution and thereby track design parameter sensitivity. In contrast to ad hoc methods, this method provides a more concise procedure following the model design intent and determining the sensitivity of CAD geometry directly to its respective defining parameters.

  12. Computer Aided Design of Computer Generated Holograms for electron beam fabrication

    NASA Technical Reports Server (NTRS)

    Urquhart, Kristopher S.; Lee, Sing H.; Guest, Clark C.; Feldman, Michael R.; Farhoosh, Hamid

    1989-01-01

    Computer Aided Design (CAD) systems that have been developed for electrical and mechanical design tasks are also effective tools for the process of designing Computer Generated Holograms (CGHs), particularly when these holograms are to be fabricated using electron beam lithography. CAD workstations provide efficient and convenient means of computing, storing, displaying, and preparing for fabrication many of the features that are common to CGH designs. Experience gained in the process of designing CGHs with various types of encoding methods is presented. Suggestions are made so that future workstations may further accommodate the CGH design process.

  13. [Computer aided design for fixed partial denture framework based on reverse engineering technology].

    PubMed

    Sun, Yu-chun; Lü, Pei-jun; Wang, Yong

    2006-03-01

    To explore a computer aided design (CAD) route for the framework of domestic fixed partial denture (FPD) and confirm the suitable method of 3-D CAD. The working area of a dentition model was scanned with a 3-D mechanical scanner. Using the reverse engineering (RE) software, margin and border curves were extracted and several reference curves were created to ensure the dimension and location of pontic framework that was taken from the standard database. The shoulder parts of the retainers were created after axial surfaces constructed. The connecting areas, axial line and curving surface of the framework connector were finally created. The framework of a three-unit FPD was designed with RE technology, which showed smooth surfaces and continuous contours. The design route is practical. The result of this study is significant in theory and practice, which will provide a reference for establishing the computer aided design/computer aided manufacture (CAD/CAM) system of domestic FPD.

  14. A framework for development of an intelligent system for design and manufacturing of stamping dies

    NASA Astrophysics Data System (ADS)

    Hussein, H. M. A.; Kumar, S.

    2014-07-01

    An integration of computer aided design (CAD), computer aided process planning (CAPP) and computer aided manufacturing (CAM) is required for development of an intelligent system to design and manufacture stamping dies in sheet metal industries. In this paper, a framework for development of an intelligent system for design and manufacturing of stamping dies is proposed. In the proposed framework, the intelligent system is structured in form of various expert system modules for different activities of design and manufacturing of dies. All system modules are integrated with each other. The proposed system takes its input in form of a CAD file of sheet metal part, and then system modules automate all tasks related to design and manufacturing of stamping dies. Modules are coded using Visual Basic (VB) and developed on the platform of AutoCAD software.

  15. Revision of Electro-Mechanical Drafting Program to Include CAD/D (Computer-Aided Drafting/Design). Final Report.

    ERIC Educational Resources Information Center

    Snyder, Nancy V.

    North Seattle Community College decided to integrate computer-aided design/drafting (CAD/D) into its Electro-Mechanical Drafting Program. This choice necessitated a redefinition of the program through new curriculum and course development. To initiate the project, a new industrial advisory council was formed. Major electronic and recruiting firms…

  16. CAD system for footwear design based on whole real 3D data of last surface

    NASA Astrophysics Data System (ADS)

    Song, Wanzhong; Su, Xianyu

    2000-10-01

    Two major parts of application of CAD in footwear design are studied: the development of last surface; computer-aided design of planar shoe-template. A new quasi-experiential development algorithm of last surface based on triangulation approximation is presented. This development algorithm consumes less time and does not need any interactive operation for precisely development compared with other development algorithm of last surface. Based on this algorithm, a software, SHOEMAKERTM, which contains computer aided automatic measurement, automatic development of last surface and computer aide design of shoe-template has been developed.

  17. Some Workplace Effects of CAD and CAM.

    ERIC Educational Resources Information Center

    Ebel, Karl-H.; Ulrich, Erhard

    1987-01-01

    Examines the impact of computer-aided design (CAD) and computer-aided manufacturing (CAM) on employment, work organization, working conditions, job content, training, and industrial relations in several countries. Finds little evidence of negative employment effects since productivity gains are offset by various compensatory factors. (Author/CH)

  18. Use of CAD Geometry in MDO

    NASA Technical Reports Server (NTRS)

    Samareh, Jamshid A.

    1996-01-01

    The purpose of this paper is to discuss the use of Computer-Aided Design (CAD) geometry in a Multi-Disciplinary Design Optimization (MDO) environment. Two techniques are presented to facilitate the use of CAD geometry by different disciplines, such as Computational Fluid Dynamics (CFD) and Computational Structural Mechanics (CSM). One method is to transfer the load from a CFD grid to a CSM grid. The second method is to update the CAD geometry for CSM deflection.

  19. CAD: Designs on Business.

    ERIC Educational Resources Information Center

    Milburn, Ken

    1988-01-01

    Provides a general review of the field of Computer-Aided Design Software including specific reviews of "Autosketch,""Generic CADD,""Drafix 1 Plus,""FastCAD," and "Autocad Release 9." Brief articles include "Blueprint for Generation,""CAD for Every Department,""Ideas…

  20. Engineering Technology Programs Courses Guide for Computer Aided Design and Computer Aided Manufacturing.

    ERIC Educational Resources Information Center

    Georgia Univ., Athens. Div. of Vocational Education.

    This guide describes the requirements for courses in computer-aided design and computer-aided manufacturing (CAD/CAM) that are part of engineering technology programs conducted in vocational-technical schools in Georgia. The guide is organized in five sections. The first section provides a rationale for occupations in design and in production,…

  1. Teaching for CAD Expertise

    ERIC Educational Resources Information Center

    Chester, Ivan

    2007-01-01

    CAD (Computer Aided Design) has now become an integral part of Technology Education. The recent introduction of highly sophisticated, low-cost CAD software and CAM hardware capable of running on desktop computers has accelerated this trend. There is now quite widespread introduction of solid modeling CAD software into secondary schools but how…

  2. The application of computer-aided technologies in automotive styling design

    NASA Astrophysics Data System (ADS)

    Zheng, Ze-feng; Zhang, Ji; Zheng, Ying

    2012-04-01

    In automotive industry, outline design is its life and creative design is its soul indeed. Computer-aided technology has been widely used in the automotive industry and more and more attention has been paid. This paper chiefly introduce the application of computer-aided technologies including CAD, CAM and CAE, analyses the process of automotive structural design and describe the development tendency of computer-aided design.

  3. CAD Services: an Industry Standard Interface for Mechanical CAD Interoperability

    NASA Technical Reports Server (NTRS)

    Claus, Russell; Weitzer, Ilan

    2002-01-01

    Most organizations seek to design and develop new products in increasingly shorter time periods. At the same time, increased performance demands require a team-based multidisciplinary design process that may span several organizations. One approach to meet these demands is to use 'Geometry Centric' design. In this approach, design engineers team their efforts through one united representation of the design that is usually captured in a CAD system. Standards-based interfaces are critical to provide uniform, simple, distributed services that enable the 'Geometry Centric' design approach. This paper describes an industry-wide effort, under the Object Management Group's (OMG) Manufacturing Domain Task Force, to define interfaces that enable the interoperability of CAD, Computer Aided Manufacturing (CAM), and Computer Aided Engineering (CAE) tools. This critical link to enable 'Geometry Centric' design is called: Cad Services V1.0. This paper discusses the features of this standard and proposed application.

  4. Increasing productivity of the McAuto CAD/CAE system by user-specific applications programming

    NASA Technical Reports Server (NTRS)

    Plotrowski, S. M.; Vu, T. H.

    1985-01-01

    Significant improvements in the productivity of the McAuto Computer-Aided Design/Computer-Aided Engineering (CAD/CAE) system were achieved by applications programming using the system's own Graphics Interactive Programming language (GRIP) and the interface capabilities with the main computer on which the system resides. The GRIP programs for creating springs, bar charts, finite element model representations and aiding management planning are presented as examples.

  5. Complete Dentures Fabricated with CAD/CAM Technology and a Traditional Clinical Recording Method.

    PubMed

    Janeva, Nadica; Kovacevska, Gordana; Janev, Edvard

    2017-10-15

    The introduction of computer-aided design/computer-aided manufacturing (CAD/CAM) technology into complete denture (CD) fabrication ushered in a new era in removable prosthodontics. Commercially available CAD/CAM denture systems are expected to improve upon the disadvantages associated with conventional fabrication. The purpose of this report is to present the workflow involved in fabricating a CD with a traditional clinical recording method and CAD/CAM technology and to summarize the advantages to the dental practitioner and the patient.

  6. Computing Mass Properties From AutoCAD

    NASA Technical Reports Server (NTRS)

    Jones, A.

    1990-01-01

    Mass properties of structures computed from data in drawings. AutoCAD to Mass Properties (ACTOMP) computer program developed to facilitate quick calculations of mass properties of structures containing many simple elements in such complex configurations as trusses or sheet-metal containers. Mathematically modeled in AutoCAD or compatible computer-aided design (CAD) system in minutes by use of three-dimensional elements. Written in Microsoft Quick-Basic (Version 2.0).

  7. Schools (Students) Exchanging CAD/CAM Files over the Internet.

    ERIC Educational Resources Information Center

    Mahoney, Gary S.; Smallwood, James E.

    This document discusses how students and schools can benefit from exchanging computer-aided design/computer-aided manufacturing (CAD/CAM) files over the Internet, explains how files are exchanged, and examines the problem of selected hardware/software incompatibility. Key terms associated with information search services are defined, and several…

  8. Using the Continuum of Design Modelling Techniques to Aid the Development of CAD Modeling Skills in First Year Industrial Design Students

    ERIC Educational Resources Information Center

    Storer, I. J.; Campbell, R. I.

    2012-01-01

    Industrial Designers need to understand and command a number of modelling techniques to communicate their ideas to themselves and others. Verbal explanations, sketches, engineering drawings, computer aided design (CAD) models and physical prototypes are the most commonly used communication techniques. Within design, unlike some disciplines,…

  9. Performance evaluation of the NASA/KSC CAD/CAE and office automation LAN's

    NASA Technical Reports Server (NTRS)

    Zobrist, George W.

    1994-01-01

    This study's objective is the performance evaluation of the existing CAD/CAE (Computer Aided Design/Computer Aided Engineering) network at NASA/KSC. This evaluation also includes a similar study of the Office Automation network, since it is being planned to integrate this network into the CAD/CAE network. The Microsoft mail facility which is presently on the CAD/CAE network was monitored to determine its present usage. This performance evaluation of the various networks will aid the NASA/KSC network managers in planning for the integration of future workload requirements into the CAD/CAE network and determining the effectiveness of the planned FDDI (Fiber Distributed Data Interface) migration.

  10. [Comparative evaluation of the marginal accuracy of single crowns fabricated computer using aided design/computer aided manufacturing methods, self-curing resin and Luxatemp].

    PubMed

    Jianming, Yuan; Ying, Tang; Feng, Pan; Weixing, Xu

    2016-12-01

    This study aims to compare the marginal accuracy of single crowns fabricated using self-curing resin, Luxatemp, and computer aided design/computer aided manufacturing (CAD/CAM) methods in clinical application. A total of 30 working dies, which were obtained from 30 clinical teeth prepared with full crown as standard, were created and made into 30 self-curing resin, Luxatemp, and CAD/CAM single crowns. The restorations were seated on the working dies, and stereomicroscope was used to observe and measure the thickness of reference points. One-way analysis of variance, which was performed using SPSS 19.0 software package, compared the marginal gap widths of self-curing resin, Luxatemp, and CAD/CAM provisional crowns. The mean marginal gap widths of the fabricated self-curing resin, Luxatemp, and CAD/CAM were (179.06±33.24), (88.83±9.56), and (43.61±7.27) μm, respectively. A significant difference was observed among the three provisional crowns (P<0.05). The marginal gap width of CAD/CAM provisional crown was lower than that of the self-curing resin and Luxatemp. Thus, the CAD/CAM provisional crown offers a better remediation effect in clinical application.

  11. A Survey of CAD/CAM Technology Applications in the U.S. Shipbuilding Industry

    DTIC Science & Technology

    1984-01-01

    operation for drafting. Computer Aided Engineering (CAE) analysis is used primarily to determine the validity of design characteristics and produc- tion...include time standard generation, sea trial analysis , and group Systems integration While no systems surveyed Aided Design (CAD) is the technology... analysis . is the largest problem involving software packages. are truly integrated, many are interfaced. Computer most interfaced category with links

  12. Assessment of Chair-side Computer-Aided Design and Computer-Aided Manufacturing Restorations: A Review of the Literature

    PubMed Central

    Baroudi, Kusai; Ibraheem, Shukran Nasser

    2015-01-01

    Background: This paper aimed to evaluate the application of computer-aided design and computer-aided manufacturing (CAD-CAM) technology and the factors that affect the survival of restorations. Materials and Methods: A thorough literature search using PubMed, Medline, Embase, Science Direct, Wiley Online Library and Grey literature were performed from the year 2004 up to June 2014. Only relevant research was considered. Results: The use of chair-side CAD/CAM systems is promising in all dental branches in terms of minimizing time and effort made by dentists, technicians and patients for restoring and maintaining patient oral function and aesthetic, while providing high quality outcome. Conclusion: The way of producing and placing the restorations made with the chair-side CAD/CAM (CEREC and E4D) devices is better than restorations made by conventional laboratory procedures. PMID:25954082

  13. The effects of computer-aided design software on engineering students' spatial visualisation skills

    NASA Astrophysics Data System (ADS)

    Kösa, Temel; Karakuş, Fatih

    2018-03-01

    The purpose of this study was to determine the influence of computer-aided design (CAD) software-based instruction on the spatial visualisation skills of freshman engineering students in a computer-aided engineering drawing course. A quasi-experimental design was applied, using the Purdue Spatial Visualization Test-Visualization of Rotations (PSVT:R) for both the pre- and the post-test. The participants were 116 freshman students in the first year of their undergraduate programme in the Department of Mechanical Engineering at a university in Turkey. A total of 72 students comprised the experimental group; they were instructed with CAD-based activities in an engineering drawing course. The control group consisted of 44 students who did not attend this course. The results of the study showed that a CAD-based engineering drawing course had a positive effect on developing engineering students' spatial visualisation skills. Additionally, the results of the study showed that spatial visualisation skills can be a predictor for success in a computer-aided engineering drawing course.

  14. Surface Modeling, Solid Modeling and Finite Element Modeling. Analysis Capabilities of Computer-Assisted Design and Manufacturing Systems.

    ERIC Educational Resources Information Center

    Nee, John G.; Kare, Audhut P.

    1987-01-01

    Explores several concepts in computer assisted design/computer assisted manufacturing (CAD/CAM). Defines, evaluates, reviews and compares advanced computer-aided geometric modeling and analysis techniques. Presents the results of a survey to establish the capabilities of minicomputer based-systems with the CAD/CAM packages evaluated. (CW)

  15. Application of digital diagnostic impression, virtual planning, and computer-guided implant surgery for a CAD/CAM-fabricated, implant-supported fixed dental prosthesis: a clinical report.

    PubMed

    Stapleton, Brandon M; Lin, Wei-Shao; Ntounis, Athanasios; Harris, Bryan T; Morton, Dean

    2014-09-01

    This clinical report demonstrated the use of an implant-supported fixed dental prosthesis fabricated with a contemporary digital approach. The digital diagnostic data acquisition was completed with a digital diagnostic impression with an intraoral scanner and cone-beam computed tomography with a prefabricated universal radiographic template to design a virtual prosthetically driven implant surgical plan. A surgical template fabricated with computer-aided design and computer-aided manufacturing (CAD/CAM) was used to perform computer-guided implant surgery. The definitive digital data were then used to design the definitive CAD/CAM-fabricated fixed dental prosthesis. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  16. CAD in der Praxis

    NASA Astrophysics Data System (ADS)

    Labisch, Susanna

    Konstruktion und Fertigung erfolgen in der Praxis fast ausschließlich rechnerunterstützt. Mit diesem Rechnereinsatz beim Konstruieren (CAD, Computer Aided Design) und Fertigen CAM (Computer Aided Manufacturing) scheint die technische Zeichnung an Bedeutung zu verlieren, da die Verständigung zwischen Konstruktions- und Fertigungsabteilung primär durch den Austausch digitaler Daten erfolgen kann.

  17. The Effects of Computer-Aided Design Software on Engineering Students' Spatial Visualisation Skills

    ERIC Educational Resources Information Center

    Kösa, Temel; Karakus, Fatih

    2018-01-01

    The purpose of this study was to determine the influence of computer-aided design (CAD) software-based instruction on the spatial visualisation skills of freshman engineering students in a computer-aided engineering drawing course. A quasi-experimental design was applied, using the Purdue Spatial Visualization Test-Visualization of Rotations…

  18. Integrating a facial scan, virtual smile design, and 3D virtual patient for treatment with CAD-CAM ceramic veneers: A clinical report.

    PubMed

    Lin, Wei-Shao; Harris, Bryan T; Phasuk, Kamolphob; Llop, Daniel R; Morton, Dean

    2018-02-01

    This clinical report describes a digital workflow using the virtual smile design approach augmented with a static 3-dimensional (3D) virtual patient with photorealistic appearance to restore maxillary central incisors by using computer-aided design and computer-aided manufacturing (CAD-CAM) monolithic lithium disilicate ceramic veneers. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  19. CAD/CAM at a Distance: Assessing the Effectiveness of Web-Based Instruction To Meet Workforce Development Needs. AIR 2000 Annual Forum Paper.

    ERIC Educational Resources Information Center

    Wilkerson, Joyce A.; Elkins, Susan A.

    This qualitative case study assessed web-based instruction in a computer-aided design/computer-assisted manufacturing (CAD/CAM) course designed for workforce development. The study examined students' and instructors' experience in a CAD/CAM course delivered exclusively on the Internet, evaluating course content and delivery, clarity of…

  20. Evaluation of Five Microcomputer CAD Packages.

    ERIC Educational Resources Information Center

    Leach, James A.

    1987-01-01

    Discusses the similarities, differences, advanced features, applications and number of users of five microcomputer computer-aided design (CAD) packages. Included are: "AutoCAD (V.2.17)"; "CADKEY (V.2.0)"; "CADVANCE (V.1.0)"; "Super MicroCAD"; and "VersaCAD Advanced (V.4.00)." Describes the…

  1. An Evaluation of Internet-Based CAD Collaboration Tools

    ERIC Educational Resources Information Center

    Smith, Shana Shiang-Fong

    2004-01-01

    Due to the now widespread use of the Internet, most companies now require computer aided design (CAD) tools that support distributed collaborative design on the Internet. Such CAD tools should enable designers to share product models, as well as related data, from geographically distant locations. However, integrated collaborative design…

  2. CAD/CAM (Computer Aided Design/Computer Aided Manufacture). A Brief Guide to Materials in the Library of Congress.

    ERIC Educational Resources Information Center

    Havas, George D.

    This brief guide to materials in the Library of Congress (LC) on computer aided design and/or computer aided manufacturing lists reference materials and other information sources under 13 headings: (1) brief introductions; (2) LC subject headings used for such materials; (3) textbooks; (4) additional titles; (5) glossaries and handbooks; (6)…

  3. A SINDA thermal model using CAD/CAE technologies

    NASA Technical Reports Server (NTRS)

    Rodriguez, Jose A.; Spencer, Steve

    1992-01-01

    The approach to thermal analysis described by this paper is a technique that incorporates Computer Aided Design (CAD) and Computer Aided Engineering (CAE) to develop a thermal model that has the advantages of Finite Element Methods (FEM) without abandoning the unique advantages of Finite Difference Methods (FDM) in the analysis of thermal systems. The incorporation of existing CAD geometry, the powerful use of a pre and post processor and the ability to do interdisciplinary analysis, will be described.

  4. In vitro Fracture strength and hardness of different computer-aided design/computer-aided manufacturing inlays.

    PubMed

    Sagsoz, O; Yildiz, M; Hojjat Ghahramanzadeh, A S L; Alsaran, A

    2018-03-01

    The purpose of this study was to examine the fracture strength and surface microhardness of computer-aided design/computer-aided manufacturing (CAD/CAM) materials in vitro. Mesial-occlusal-distal inlays were made from five different CAD/CAM materials (feldspathic ceramic, CEREC blocs; leucite-reinforced ceramic, IPS Empress CAD; resin nano ceramic, 3M ESPE Lava Ultimate; hybrid ceramic, VITA Enamic; and lithium disilicate ceramic, IPS e.max CAD) using CEREC 4 CAD/CAM system. Samples were adhesively cemented to metal analogs with a resin cement (3M ESPE, U200). The fracture tests were carried out with a universal testing machine. Furthermore, five samples were prepared from each CAD/CAM material for micro-Vickers hardness test. Data were analyzed with statistics software SPSS 20 (IBM Corp., New York, USA). Fracture strength of lithium disilicate inlays (3949 N) was found to be higher than other ceramic inlays (P < 0.05). There was no difference between other inlays statistically (P > 0.05). The highest micro-Vickers hardness was measured in lithium disilicate samples, and the lowest was in resin nano ceramic samples. Fracture strength results demonstrate that inlays can withstand the forces in the mouth. Statistical results showed that fracture strength and micro-Vickers hardness of feldspathic ceramic, leucite-reinforced ceramic, and lithium disilicate ceramic materials had a positive correlation.

  5. Understanding dental CAD/CAM for restorations--the digital workflow from a mechanical engineering viewpoint.

    PubMed

    Tapie, L; Lebon, N; Mawussi, B; Fron Chabouis, H; Duret, F; Attal, J-P

    2015-01-01

    As digital technology infiltrates every area of daily life, including the field of medicine, so it is increasingly being introduced into dental practice. Apart from chairside practice, computer-aided design/computer-aided manufacturing (CAD/CAM) solutions are available for creating inlays, crowns, fixed partial dentures (FPDs), implant abutments, and other dental prostheses. CAD/CAM dental solutions can be considered a chain of digital devices and software for the almost automatic design and creation of dental restorations. However, dentists who want to use the technology often do not have the time or knowledge to understand it. A basic knowledge of the CAD/CAM digital workflow for dental restorations can help dentists to grasp the technology and purchase a CAM/CAM system that meets the needs of their office. This article provides a computer-science and mechanical-engineering approach to the CAD/CAM digital workflow to help dentists understand the technology.

  6. Computer-aided design and computer-aided manufacturing cutting guides and customized titanium plates are useful in upper maxilla waferless repositioning.

    PubMed

    Mazzoni, Simona; Bianchi, Alberto; Schiariti, Giulio; Badiali, Giovanni; Marchetti, Claudio

    2015-04-01

    The purpose of the present study was to develop a computer-aided design (CAD) and computer-aided manufacturing (CAM) technique that enabled fabrication of surgical cutting guides and titanium fixation plates that would allow the upper maxilla to be repositioned correctly without a surgical splint in orthognathic patients. Ten patients were recruited. A complete CAD-CAM workflow for orthognathic surgery has 3 steps: 1) virtual planning of the surgical treatment, 2) CAD-CAM and 3-dimensional printing of customized surgical devices (surgical cutting guide and titanium fixation plates), and 3) computer-aided surgery. Upper maxilla repositioning was performed in a waferless manner using a CAD-CAM device: the surgical cutting guide was used during surgery to pilot the osteotomy line that had been planned preoperatively at the computer and the custom-made fixation titanium plates allowed desired repositioning of the maxilla. To evaluate the reproducibility of this CAD-CAM orthognathic surgical method, the virtually planned and actually achieved positions of the upper maxilla were compared. Overlap errors using a threshold value smaller than 2 mm were evaluated, and the frequency of such errors was used as a measurement of accuracy. By this definition, the accuracy was 100% in 7 patients (range in all patients, 62 to 100%; median, 92.7%). These results tend to confirm that the use of CAD-CAM cutting guides and customized titanium plates for upper maxilla repositioning represents a promising method for the accurate reproduction of preoperative virtual planning without the use of surgical splints. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  7. Dual-scan technique for the customization of zirconia computer-aided design/computer-aided manufacturing frameworks.

    PubMed

    Andreiuolo, Rafael Ferrone; Sabrosa, Carlos Eduardo; Dias, Katia Regina H Cervantes

    2013-09-01

    The use of bi-layered all-ceramic crowns has continuously grown since the introduction of computer-aided design/computer-aided manufacturing (CAD/CAM) zirconia cores. Unfortunately, despite the outstanding mechanical properties of zirconia, problems related to porcelain cracking or chipping remain. One of the reasons for this is that ceramic copings are usually milled to uniform thicknesses of 0.3-0.6 mm around the whole tooth preparation. This may not provide uniform thickness or appropriate support for the veneering porcelain. To prevent these problems, the dual-scan technique demonstrates an alternative that allows the restorative team to customize zirconia CAD/CAM frameworks with adequate porcelain thickness and support in a simple manner.

  8. The Use of a Parametric Feature Based CAD System to Teach Introductory Engineering Graphics.

    ERIC Educational Resources Information Center

    Howell, Steven K.

    1995-01-01

    Describes the use of a parametric-feature-based computer-aided design (CAD) System, AutoCAD Designer, in teaching concepts of three dimensional geometrical modeling and design. Allows engineering graphics to go beyond the role of documentation and communication and allows an engineer to actually build a virtual prototype of a design idea and…

  9. Computer Assisted Instructional Design for Computer-Based Instruction. Final Report. Working Papers.

    ERIC Educational Resources Information Center

    Russell, Daniel M.; Pirolli, Peter

    Recent advances in artificial intelligence and the cognitive sciences have made it possible to develop successful intelligent computer-aided instructional systems for technical and scientific training. In addition, computer-aided design (CAD) environments that support the rapid development of such computer-based instruction have also been recently…

  10. Application of computer-aided dispatch in law enforcement: An introductory planning guide

    NASA Technical Reports Server (NTRS)

    Sohn, R. L.; Gurfield, R. M.; Garcia, E. A.; Fielding, J. E.

    1975-01-01

    A set of planning guidelines for the application of computer-aided dispatching (CAD) to law enforcement is presented. Some essential characteristics and applications of CAD are outlined; the results of a survey of systems in the operational or planning phases are summarized. Requirements analysis, system concept design, implementation planning, and performance and cost modeling are described and demonstrated with numerous examples. Detailed descriptions of typical law enforcement CAD systems, and a list of vendor sources, are given in appendixes.

  11. ACSYNT - A standards-based system for parametric, computer aided conceptual design of aircraft

    NASA Technical Reports Server (NTRS)

    Jayaram, S.; Myklebust, A.; Gelhausen, P.

    1992-01-01

    A group of eight US aerospace companies together with several NASA and NAVY centers, led by NASA Ames Systems Analysis Branch, and Virginia Tech's CAD Laboratory agreed, through the assistance of Americal Technology Initiative, in 1990 to form the ACSYNT (Aircraft Synthesis) Institute. The Institute is supported by a Joint Sponsored Research Agreement to continue the research and development in computer aided conceptual design of aircraft initiated by NASA Ames Research Center and Virginia Tech's CAD Laboratory. The result of this collaboration, a feature-based, parametric computer aided aircraft conceptual design code called ACSYNT, is described. The code is based on analysis routines begun at NASA Ames in the early 1970's. ACSYNT's CAD system is based entirely on the ISO standard Programmer's Hierarchical Interactive Graphics System and is graphics-device independent. The code includes a highly interactive graphical user interface, automatically generated Hermite and B-Spline surface models, and shaded image displays. Numerous features to enhance aircraft conceptual design are described.

  12. Project Integration Architecture (PIA) and Computational Analysis Programming Interface (CAPRI) for Accessing Geometry Data from CAD Files

    NASA Technical Reports Server (NTRS)

    Benyo, Theresa L.

    2002-01-01

    Integration of a supersonic inlet simulation with a computer aided design (CAD) system is demonstrated. The integration is performed using the Project Integration Architecture (PIA). PIA provides a common environment for wrapping many types of applications. Accessing geometry data from CAD files is accomplished by incorporating appropriate function calls from the Computational Analysis Programming Interface (CAPRI). CAPRI is a CAD vendor neutral programming interface that aids in acquiring geometry data directly from CAD files. The benefits of wrapping a supersonic inlet simulation into PIA using CAPRI are; direct access of geometry data, accurate capture of geometry data, automatic conversion of data units, CAD vendor neutral operation, and on-line interactive history capture. This paper describes the PIA and the CAPRI wrapper and details the supersonic inlet simulation demonstration.

  13. Digital approach to planning computer-guided surgery and immediate provisionalization in a partially edentulous patient.

    PubMed

    Arunyanak, Sirikarn P; Harris, Bryan T; Grant, Gerald T; Morton, Dean; Lin, Wei-Shao

    2016-07-01

    This report describes a digital approach for computer-guided surgery and immediate provisionalization in a partially edentulous patient. With diagnostic data obtained from cone-beam computed tomography and intraoral digital diagnostic scans, a digital pathway of virtual diagnostic waxing, a virtual prosthetically driven surgical plan, a computer-aided design and computer-aided manufacturing (CAD/CAM) surgical template, and implant-supported screw-retained interim restorations were realized with various open-architecture CAD/CAM systems. The optional CAD/CAM diagnostic casts with planned implant placement were also additively manufactured to facilitate preoperative inspection of the surgical template and customization of the CAD/CAM-fabricated interim restorations. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  14. The application of CAD / CAM technology in Dentistry

    NASA Astrophysics Data System (ADS)

    Susic, I.; Travar, M.; Susic, M.

    2017-05-01

    Information and communication technologies have found their application in the healthcare sector, including the frameworks of modern dentistry. CAD / CAM application in dentistry is the process by which is attained finished dental restoration through fine milling process of ready ceramic blocks. CAD / CAM is an acronym of english words Computer-Aided-Design (CAD) / Computer-Aided-Manufacture (CAM), respectively dental computer aided design and computer aided manufacture of inlays, onlays, crowns and bridges. CAD / CAM technology essentially allows you to create a two-dimensional and three-dimensional models and their materialization by numerical controlled machines. In order to operate more efficiently, reduce costs, increase user/patient satisfaction and ultimately achieve profits, many dental offices in the world have their attention focused on implementation of modern IT solutions in everyday practice. In addition to the specialized clinic management software, inventory control, etc., or hardware such as the use of lasers in cosmetic dentistry or intraoral scanning, recently the importance is given to the application of CAD / CAM technology in the field of prosthetic. After the removal of pathologically altered tooth structure, it is necessary to achieve restoration that will be most similar to the anatomy of a natural tooth. Applying CAD / CAM technology on applicable ceramic blocks it can be obtained very quick, but also very accurate restoration, in the forms of inlays, onlays, bridges and crowns. The paper presents the advantages of using this technology as well as satisfaction of the patients and dentists by using systems as: Cercon, Celay, Cerec, Lava, Everest, which represent imperative of modern dentistry in creating fixed dental restorations.

  15. Costs incurred by applying computer-aided design/computer-aided manufacturing techniques for the reconstruction of maxillofacial defects.

    PubMed

    Rustemeyer, Jan; Melenberg, Alex; Sari-Rieger, Aynur

    2014-12-01

    This study aims to evaluate the additional costs incurred by using a computer-aided design/computer-aided manufacturing (CAD/CAM) technique for reconstructing maxillofacial defects by analyzing typical cases. The medical charts of 11 consecutive patients who were subjected to the CAD/CAM technique were considered, and invoices from the companies providing the CAD/CAM devices were reviewed for every case. The number of devices used was significantly correlated with cost (r = 0.880; p < 0.001). Significant differences in mean costs were found between cases in which prebent reconstruction plates were used (€3346.00 ± €29.00) and cases in which they were not (€2534.22 ± €264.48; p < 0.001). Significant differences were also obtained between the costs of two, three and four devices, even when ignoring the cost of reconstruction plates. Additional fees provided by statutory health insurance covered a mean of 171.5% ± 25.6% of the cost of the CAD/CAM devices. Since the additional fees provide financial compensation, we believe that the CAD/CAM technique is suited for wide application and not restricted to complex cases. Where additional fees/funds are not available, the CAD/CAM technique might be unprofitable, so the decision whether or not to use it remains a case-to-case decision with respect to cost versus benefit. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  16. Application programs written by using customizing tools of a computer-aided design system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, X.; Huang, R.; Juricic, D.

    1995-12-31

    Customizing tools of Computer-Aided Design Systems have been developed to such a degree as to become equivalent to powerful higher-level programming languages that are especially suitable for graphics applications. Two examples of application programs written by using AutoCAD`s customizing tools are given in some detail to illustrate their power. One tool uses AutoLISP list-processing language to develop an application program that produces four views of a given solid model. The other uses AutoCAD Developmental System, based on program modules written in C, to produce an application program that renders a freehand sketch from a given CAD drawing.

  17. Implementing a new curriculum for computer-assisted restorations in prosthetic dentistry.

    PubMed

    Schweyen, R; Beuer, F; Bochskanl, M; Hey, J

    2018-05-01

    Computer-aided design/computer-aided manufacturing (CAD/CAM) of fixed prosthetic restorations has gained popularity in the last decade. However, this field of dentistry has not been integrated in the dental curriculum at most universities. According to the method of Kern, a curriculum was designed and established on a voluntary basis in the prosthetic education of a German dental school. The success of the implementation was measured by evaluation carried out by the participants on a visual analogue scale. Furthermore, the clinical performance of the fabricated restorations was evaluated. Ninety-four percent of all students participated in the CAD/CAM curriculum indicating considerable interest. Nearly half of all students used the acquired knowledge to design crowns for their patients. All restorations fabricated by participants of the new CAD/CAM programme showed good clinical performance. By phasing-in the CAD/CAM training programme, independent CAD/CAM-based fabrication of all-ceramic crowns increased student's self-confidence in tooth preparation. A tendency was found that students using CAD/CAM technology prepared more teeth than their fellow students who did not use CAD/CAM technology. Further studies are required to investigate the influence of independent CAD/CAM-based single-crown fabrication on the quality of the preparation. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Overview of NASA MSFC IEC Multi-CAD Collaboration Capability

    NASA Technical Reports Server (NTRS)

    Moushon, Brian; McDuffee, Patrick

    2005-01-01

    This viewgraph presentation provides an overview of a Design and Data Management System (DDMS) for Computer Aided Design (CAD) collaboration in order to support the Integrated Engineering Capability (IEC) at Marshall Space Flight Center (MSFC).

  19. CAD-CAE in Electrical Machines and Drives Teaching.

    ERIC Educational Resources Information Center

    Belmans, R.; Geysen, W.

    1988-01-01

    Describes the use of computer-aided design (CAD) techniques in teaching the design of electrical motors. Approaches described include three technical viewpoints, such as electromagnetics, thermal, and mechanical aspects. Provides three diagrams, a table, and conclusions. (YP)

  20. Manipulating the Geometric Computer-aided Design of the Operational Requirements-based Casualty Assessment Model within BRL-CAD

    DTIC Science & Technology

    2018-03-30

    ARL-TR-8336 ● MAR 2018 US Army Research Laboratory Manipulating the Geometric Computer-aided Design of the Operational...so designated by other authorized documents. Citation of manufacturer’s or trade names does not constitute an official endorsement or approval of...Army Research Laboratory Manipulating the Geometric Computer-aided Design of the Operational Requirements-based Casualty Assessment Model within

  1. Rationale for the Use of CAD/CAM Technology in Implant Prosthodontics

    PubMed Central

    Abduo, Jaafar; Lyons, Karl

    2013-01-01

    Despite the predictable longevity of implant prosthesis, there is an ongoing interest to continue to improve implant prosthodontic treatment and outcomes. One of the developments is the application of computer-aided design and computer-aided manufacturing (CAD/CAM) to produce implant abutments and frameworks from metal or ceramic materials. The aim of this narrative review is to critically evaluate the rationale of CAD/CAM utilization for implant prosthodontics. To date, CAD/CAM allows simplified production of precise and durable implant components. The precision of fit has been proven in several laboratory experiments and has been attributed to the design of implants. Milling also facilitates component fabrication from durable and aesthetic materials. With further development, it is expected that the CAD/CAM protocol will be further simplified. Although compelling clinical evidence supporting the superiority of CAD/CAM implant restorations is still lacking, it is envisioned that CAD/CAM may become the main stream for implant component fabrication. PMID:23690778

  2. CAD/CAM complete dentures: a review of two commercial fabrication systems.

    PubMed

    Kattadiyil, Mathew T; Goodacre, Charles J; Baba, Nadim Z

    2013-06-01

    The use of computer-aided design and computer-aided manufacturing (CAD/CAM) has become available for complete dentures through the AvaDent and Dentca systems. AvaDent uses laser scanning and computer technology. Teeth are arranged and bases formed using proprietary software.The bases are milled from prepolymerized pucks of resin. Dentca uses computer software to produce virtual maxillary and mandibular edentulous ridges, arrange the teeth and form bases. The dentures are fabricated using a conventional processing technique.

  3. A review of computer-aided design/computer-aided manufacture techniques for removable denture fabrication.

    PubMed

    Bilgin, Mehmet Selim; Baytaroğlu, Ebru Nur; Erdem, Ali; Dilber, Erhan

    2016-01-01

    The aim of this review was to investigate usage of computer-aided design/computer-aided manufacture (CAD/CAM) such as milling and rapid prototyping (RP) technologies for removable denture fabrication. An electronic search was conducted in the PubMed/MEDLINE, ScienceDirect, Google Scholar, and Web of Science databases. Databases were searched from 1987 to 2014. The search was performed using a variety of keywords including CAD/CAM, complete/partial dentures, RP, rapid manufacturing, digitally designed, milled, computerized, and machined. The identified developments (in chronological order), techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication are summarized. Using a variety of keywords and aiming to find the topic, 78 publications were initially searched. For the main topic, the abstract of these 78 articles were scanned, and 52 publications were selected for reading in detail. Full-text of these articles was gained and searched in detail. Totally, 40 articles that discussed the techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication and the articles were incorporated in this review. Totally, 16 of the papers summarized in the table. Following review of all relevant publications, it can be concluded that current innovations and technological developments of CAD/CAM and RP allow the digitally planning and manufacturing of removable dentures from start to finish. As a result according to the literature review CAD/CAM techniques and supportive maxillomandibular relationship transfer devices are growing fast. In the close future, fabricating removable dentures will become medical informatics instead of needing a technical staff and procedures. However the methods have several limitations for now.

  4. A review of computer-aided design/computer-aided manufacture techniques for removable denture fabrication

    PubMed Central

    Bilgin, Mehmet Selim; Baytaroğlu, Ebru Nur; Erdem, Ali; Dilber, Erhan

    2016-01-01

    The aim of this review was to investigate usage of computer-aided design/computer-aided manufacture (CAD/CAM) such as milling and rapid prototyping (RP) technologies for removable denture fabrication. An electronic search was conducted in the PubMed/MEDLINE, ScienceDirect, Google Scholar, and Web of Science databases. Databases were searched from 1987 to 2014. The search was performed using a variety of keywords including CAD/CAM, complete/partial dentures, RP, rapid manufacturing, digitally designed, milled, computerized, and machined. The identified developments (in chronological order), techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication are summarized. Using a variety of keywords and aiming to find the topic, 78 publications were initially searched. For the main topic, the abstract of these 78 articles were scanned, and 52 publications were selected for reading in detail. Full-text of these articles was gained and searched in detail. Totally, 40 articles that discussed the techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication and the articles were incorporated in this review. Totally, 16 of the papers summarized in the table. Following review of all relevant publications, it can be concluded that current innovations and technological developments of CAD/CAM and RP allow the digitally planning and manufacturing of removable dentures from start to finish. As a result according to the literature review CAD/CAM techniques and supportive maxillomandibular relationship transfer devices are growing fast. In the close future, fabricating removable dentures will become medical informatics instead of needing a technical staff and procedures. However the methods have several limitations for now. PMID:27095912

  5. Computer-aided dental prostheses construction using reverse engineering.

    PubMed

    Solaberrieta, E; Minguez, R; Barrenetxea, L; Sierra, E; Etxaniz, O

    2014-01-01

    The implementation of computer-aided design/computer-aided manufacturing (CAD/CAM) systems with virtual articulators, which take into account the kinematics, constitutes a breakthrough in the construction of customised dental prostheses. This paper presents a multidisciplinary protocol involving CAM techniques to produce dental prostheses. This protocol includes a step-by-step procedure using innovative reverse engineering technologies to transform completely virtual design processes into customised prostheses. A special emphasis is placed on a novel method that permits a virtual location of the models. The complete workflow includes the optical scanning of the patient, the use of reverse engineering software and, if necessary, the use of rapid prototyping to produce CAD temporary prostheses.

  6. A method for using solid modeling CAD software to create an implant library for the fabrication of a custom abutment.

    PubMed

    Zhang, Jing; Zhang, Rimei; Ren, Guanghui; Zhang, Xiaojie

    2017-02-01

    This article describes a method that incorporates the solid modeling CAD software Solidworks with a dental milling machine to fabricate individual abutments in house. This process involves creating an implant library with 3-dimensional (3D) models and manufacturing a base, scan element, abutment, and crown anatomy. The 3D models can be imported into any dental computer-aided design and computer-aided (CAD-CAM) manufacturing system. This platform increases abutment design flexibility, as the base and scan elements can be designed to fit several shapes as needed to meet clinical requirements. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  7. Bridging CAGD knowledge into CAD/CG applications: Mathematical theories as stepping stones of innovations

    NASA Astrophysics Data System (ADS)

    Gobithaasan, R. U.; Miura, Kenjiro T.; Hassan, Mohamad Nor

    2014-07-01

    Computer Aided Geometric Design (CAGD) which surpasses the underlying theories of Computer Aided Design (CAD) and Computer Graphics (CG) has been taught in a number of Malaysian universities under the umbrella of Mathematical Sciences' faculty/department. On the other hand, CAD/CG is taught either under the Engineering or Computer Science Faculty. Even though CAGD researchers/educators/students (denoted as contributors) have been enriching this field of study by means of article/journal publication, many fail to convert the idea into constructive innovation due to the gap that occurs between CAGD contributors and practitioners (engineers/product/designers/architects/artists). This paper addresses this issue by advocating a number of technologies that can be used to transform CAGD contributors into innovators where immediate impact in terms of practical application can be experienced by the CAD/CG practitioners. The underlying principle of solving this issue is twofold. First would be to expose the CAGD contributors on ways to turn mathematical ideas into plug-ins and second is to impart relevant CAGD theories to CAD/CG to practitioners. Both cases are discussed in detail and the final section shows examples to illustrate the importance of turning mathematical knowledge into innovations.

  8. Designers workbench: toward real-time immersive modeling

    NASA Astrophysics Data System (ADS)

    Kuester, Falko; Duchaineau, Mark A.; Hamann, Bernd; Joy, Kenneth I.; Ma, Kwan-Liu

    2000-05-01

    This paper introduces the Designers Workbench, a semi- immersive virtual environment for two-handed modeling, sculpting and analysis tasks. The paper outlines the fundamental tools, design metaphors and hardware components required for an intuitive real-time modeling system. As companies focus on streamlining productivity to cope with global competition, the migration to computer-aided design (CAD), computer-aided manufacturing, and computer-aided engineering systems has established a new backbone of modern industrial product development. However, traditionally a product design frequently originates form a clay model that, after digitization, forms the basis for the numerical description of CAD primitives. The Designers Workbench aims at closing this technology or 'digital gap' experienced by design and CAD engineers by transforming the classical design paradigm into its fully integrate digital and virtual analog allowing collaborative development in a semi- immersive virtual environment. This project emphasizes two key components form the classical product design cycle: freeform modeling and analysis. In the freedom modeling stage, content creation in the form of two-handed sculpting of arbitrary objects using polygonal, volumetric or mathematically defined primitives is emphasized, whereas the analysis component provides the tools required for pre- and post-processing steps for finite element analysis tasks applied to the created models.

  9. What's your relationship with computerized manufacturing technologies -- functional, dysfunctional or non-existent?

    Treesearch

    Jan Wiedenbeck; Jeff Parsons; Bruce Beeken

    2009-01-01

    Computer-aided manufacturing (CAM), in which computer-aided design (CAD) and computer numerically controlled (CNC) machining are integrated for the production of parts, became a viable option for the woodworking industry in the 1980s.

  10. Evaluation of the fracture resistance of computer-aided design/computer-aided manufacturing monolithic crowns prepared in different cement thicknesses.

    PubMed

    Sagsoz, N Polat; Yanıkoglu, N

    2018-04-01

    The purpose of this study was to evaluate the fracture resistance of monolithic computer-aided design/computer-aided manufacturing (CAD/CAM) crowns that are prepared with different cement thickness. For this investigation, a human maxillary premolar tooth was selected. Master model preparation was performed with a demand bur under water spray. Master die was taken to fabricate 105 epoxy resin replicas. The crowns were milled using a CEREC 4 CAD/CAM system (Software Version, 4.2.0.57192). CAD/CAM crowns were made using resin nanoceramic, feldspathic glass ceramic, lithium disilicate, and leucite-reinforced ceramics. Each group was subdivided into three groups in accordance with three different cement thicknesses (30, 90, and 150 μm). Crowns milled out. Then RelyX ™ U200 was used as a luting agent to bond the crowns to the prepared samples. After one hour cementations, the specimens were stored in water bath at 37°C for 1 week before testing. Seven unprepared and unrestored teeth were kept and tested as a control group. A universal test machine was used to assume the fracture resistance of all specimens. The compressive load (N) that caused fracture was recorded for each specimen. Fracture resistance data were statistically analyzed by one-way ANOVA and two-factor interaction modeling test (α = 0.001). There are statistically significant differences between fracture resistances of CAD/CAM monolithic crown materials (P < 0.001). It is seen that cement thickness is not statistically significant for fracture resistance of CAD/CAM monolithic crowns (P > 0.001). CAD/CAM monolithic crown materials affected fracture resistance. Cement thickness (30, 90, and 150 μm) was not effective on fracture resistance of CAD/CAM monolithic crowns.

  11. [Initial evolution research for design and process accuracy of one type of domestic computer aided design soft and computer aided manufacture].

    PubMed

    Song, Yang; Zhao, Yi-jiao; Sun, Yu-chun; Lü, Pei-jun; Wang, Yong

    2013-09-01

    To evaluate the design and manufacture accuracy of a domestic computer aided design (CAD) and computer aided manufacture (CAM) system, and to compare it with similar foreign products. Thirty models of posterior-teeth-single-crown preparations were collected, and STL data of these preparations was collected by Denmark 3Shape scanner. Three copings were made for each preparation, the one designed and manufactured using commercial CAD/CAM system (3Shape CAD software and Wieland T1 CAM equipment) was assigned into control group T0, the one designed and manufactured using domestic CAD software (developed by Peking University School and Hospital of Stomatology and Nanjing University of Aeronautics and Astronautics) and Wieland T1 CAM equipment was assigned into experimental group TCAD for design accuracy evaluation, and the one designed and manufactured using 3Shape CAD software and domestic CAM equipment (developed by Peking University School and Hospital of Stomatology, Tsinghua University and ShanDong XinHua Incorporated Company of medical apparatus and instruments) was assigned into experimental group TCAM for manufacture accuracy evaluation. Finally, the marginal fitness were compared and evaluated by using 3D & Profile measurement microscope laser. The marginal fitness of TCAD was 27.98 (19.10, 46.57) µm in buccal, 32.67 (20.65, 50.82) µm in lingual, 27.38 (22.53, 52.61) µm in mesial, 29.50 (22.68, 53.65) µm in distal; of TCAM was 21.69 (15.87, 30.21) µm in buccal, 18.51 (13.50, 22.51) µm in lingual, 19.15 (15.42, 26.89) µm in mesial, 22.77 (18.58, 32.15) µm in distal; and there were no statistical differences compared with T0 [20.16 (17.16, 48.00) µm in buccal, 21.51 (17.05, 28.31) µm in lingual, 23.54 (17.89, 30.04) µm in mesial and 23.94 (17.93, 28.19) µm in distal] except lingual data of TCAD. The design and machining precision of this domestic CAD/CAM system is at the same level of those comparable foreign products.

  12. Freeform surface measurement and characterisation using a toolmakers microscope

    NASA Astrophysics Data System (ADS)

    Seung-yin Wong, Francis; Chauh, Kong-Bieng; Venuvinod, Patri K.

    2014-03-01

    Current freeform surface (FFS) characterization systems mainly cover aspects related to computer-aided design/manufacture (CAD/CAM). This paper describes a new approach that extends into computer-aided inspection (CAI).The following novel features are addressed: blacksquare Feature recognition and extraction from surface data blacksquare Characterisation of properties of the surface's M and N vectors at individual vertex blacksquare Development of a measuring plan using a toolmakers microscope for the inspection of the FFS blacksquare Inspection of the actual FFS produced by CNC milling blacksquare Verification of the measurement results and comparison with the CAD design data Tests have shown that the deviations between the CAI and CAD data were within the estimated uncertainty limits.

  13. Computer Aided Manufacturing.

    ERIC Educational Resources Information Center

    Insolia, Gerard

    This document contains course outlines in computer-aided manufacturing developed for a business-industry technology resource center for firms in eastern Pennsylvania by Northampton Community College. The four units of the course cover the following: (1) introduction to computer-assisted design (CAD)/computer-assisted manufacturing (CAM); (2) CAM…

  14. Buying CAM.

    ERIC Educational Resources Information Center

    Meloy, Jim; And Others

    1990-01-01

    The relationship between computer-aided design (CAD), computer-aided manufacturing (CAM), and computer numerical control (CNC) computer applications is described. Tips for helping educate the CAM buyer on what to look for and what to avoid when searching for the most appropriate instructional CAM package are provided. (KR)

  15. Improving Perceptual Skills with 3-Dimensional Animations.

    ERIC Educational Resources Information Center

    Johns, Janet Faye; Brander, Julianne Marie

    1998-01-01

    Describes three-dimensional computer aided design (CAD) models for every component in a representative mechanical system; the CAD models made it easy to generate 3-D animations that are ideal for teaching perceptual skills in multimedia computer-based technical training. Fifteen illustrations are provided. (AEF)

  16. Computer-aided design of polymers and composites

    NASA Technical Reports Server (NTRS)

    Kaelble, D. H.

    1985-01-01

    This book on computer-aided design of polymers and composites introduces and discusses the subject from the viewpoint of atomic and molecular models. Thus, the origins of stiffness, strength, extensibility, and fracture toughness in composite materials can be analyzed directly in terms of chemical composition and molecular structure. Aspects of polymer composite reliability are considered along with characterization techniques for composite reliability, relations between atomic and molecular properties, computer aided design and manufacture, polymer CAD/CAM models, and composite CAD/CAM models. Attention is given to multiphase structural adhesives, fibrous composite reliability, metal joint reliability, polymer physical states and transitions, chemical quality assurance, processability testing, cure monitoring and management, nondestructive evaluation (NDE), surface NDE, elementary properties, ionic-covalent bonding, molecular analysis, acid-base interactions, the manufacturing science, and peel mechanics.

  17. Using Computer Graphics in the 90's.

    ERIC Educational Resources Information Center

    Towne, Violet A.

    Computer-Aided Design, a hands-on program for public school teachers, was first offered in the summer of 1987 as an outgrowth of a 1986 robotics training program. Area technology teachers needed computer-aided design (CAD) training because of a New York State Education system transition from the industrial arts curriculum to a new curriculum in…

  18. Endodontic Management of a Mandibular First Molar with Radix Entomolaris and Conservative Post-endodontic Restoration with CAD/CAM Onlay: A Novel Clinical Technique

    PubMed Central

    De Ataide, Ida De Noronha; Fernandes, Marina; Lambor, Rajan; Alreja, Dalip

    2016-01-01

    This case report describes a novel technique of restoring endodontically treated teeth. Hidden caries causing irreversible pulpitis in a mandibular molar with Radix Entomolaris (RE) was evident. The intact occlusal surface anatomy was duplicated before preparing an access cavity to replicate the original occlusal surface in the post endodontic restoration using (Computer-Aided Design and Computer-Aided Manufacturing) CAD/CAM technique. This report highlights uniquely designed onlay utilizing the benefits of contemporary materials and advanced technology. PMID:28050515

  19. Fabricating CAD/CAM Implant-Retained Mandibular Bar Overdentures: A Clinical and Technical Overview.

    PubMed

    Goo, Chui Ling; Tan, Keson Beng Choon

    2017-01-01

    This report describes the clinical and technical aspects in the oral rehabilitation of an edentulous patient with knife-edge ridge at the mandibular anterior edentulous region, using implant-retained overdentures. The application of computer-aided design and computer-aided manufacturing (CAD/CAM) in the fabrication of the overdenture framework simplifies the laboratory process of the implant prostheses. The Nobel Procera CAD/CAM System was utilised to produce a lightweight titanium overdenture bar with locator attachments. It is proposed that the digital workflow of CAD/CAM milled implant overdenture bar allows us to avoid numerous technical steps and possibility of casting errors involved in the conventional casting of such bars.

  20. Guided Immediate Implant Placement with Wound Closure by Computer-Aided Design/Computer-Assisted Manufacture Sealing Socket Abutment: Case Report.

    PubMed

    Finelle, Gary; Lee, Sang J

    Digital technology has been widely used in the field of implant dentistry. From a surgical standpoint, computer-guided surgery can be utilized to enhance primary implant stability and to improve the precision of implant placement. From a prosthetic standpoint, computer-aided design/computer-assisted manufacture (CAD/CAM) technology has brought about various restorative options, including the fabrication of customized abutments through a virtual design based on computer-guided surgical planning. This case report describes a novel technique combining the use of a three-dimensional (3D) printed surgical template for the immediate placement of an implant, with CAD/CAM technology to optimize hard and soft tissue healing after bone grafting with the use of a socket sealing abutment.

  1. Application of virtual surgical planning with computer assisted design and manufacturing technology to cranio-maxillofacial surgery.

    PubMed

    Zhao, Linping; Patel, Pravin K; Cohen, Mimis

    2012-07-01

    Computer aided design and manufacturing (CAD/CAM) technology today is the standard in manufacturing industry. The application of the CAD/CAM technology, together with the emerging 3D medical images based virtual surgical planning (VSP) technology, to craniomaxillofacial reconstruction has been gaining increasing attention to reconstructive surgeons. This article illustrates the components, system and clinical management of the VSP and CAD/CAM technology including: data acquisition, virtual surgical and treatment planning, individual implant design and fabrication, and outcome assessment. It focuses primarily on the technical aspects of the VSP and CAD/CAM system to improve the predictability of the planning and outcome.

  2. Extending Engineering Design Graphics Laboratories to Have a CAD/CAM Component: Implementation Issues.

    ERIC Educational Resources Information Center

    Juricic, Davor; Barr, Ronald E.

    1996-01-01

    Reports on a project that extended the Engineering Design Graphics curriculum to include instruction and laboratory experience in computer-aided design, analysis, and manufacturing (CAD/CAM). Discusses issues in project implementation, including introduction of finite element analysis to lower-division students, feasibility of classroom prototype…

  3. Project CAD as of July 1978: CAD support project, situation in July 1978

    NASA Technical Reports Server (NTRS)

    Boesch, L.; Lang-Lendorff, G.; Rothenberg, R.; Stelzer, V.

    1979-01-01

    The structure of Computer Aided Design (CAD) and the requirements for program developments in past and future are described. The actual standard and the future aims of CAD programs are presented. The developed programs in: (1) civil engineering; (2) mechanical engineering; (3) chemical engineering/shipbuilding; (4) electrical engineering; and (5) general programs are discussed.

  4. Three-Dimensional Computational Fluid Dynamics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haworth, D.C.; O'Rourke, P.J.; Ranganathan, R.

    1998-09-01

    Computational fluid dynamics (CFD) is one discipline falling under the broad heading of computer-aided engineering (CAE). CAE, together with computer-aided design (CAD) and computer-aided manufacturing (CAM), comprise a mathematical-based approach to engineering product and process design, analysis and fabrication. In this overview of CFD for the design engineer, our purposes are three-fold: (1) to define the scope of CFD and motivate its utility for engineering, (2) to provide a basic technical foundation for CFD, and (3) to convey how CFD is incorporated into engineering product and process design.

  5. On the Use of CAD-Native Predicates and Geometry in Surface Meshing

    NASA Technical Reports Server (NTRS)

    Aftosmis, M. J.

    1999-01-01

    Several paradigms for accessing computer-aided design (CAD) geometry during surface meshing for computational fluid dynamics are discussed. File translation, inconsistent geometry engines, and nonnative point construction are all identified as sources of nonrobustness. The paper argues in favor of accessing CAD parts and assemblies in their native format, without translation, and for the use of CAD-native predicates and constructors in surface mesh generation. The discussion also emphasizes the importance of examining the computational requirements for exact evaluation of triangulation predicates during surface meshing.

  6. Understanding dental CAD/CAM for restorations--accuracy from a mechanical engineering viewpoint.

    PubMed

    Tapie, Laurent; Lebon, Nicolas; Mawussi, Bernardin; Fron-Chabouis, Hélène; Duret, Francois; Attal, Jean-Pierre

    2015-01-01

    As is the case in the field of medicine, as well as in most areas of daily life, digital technology is increasingly being introduced into dental practice. Computer-aided design/ computer-aided manufacturing (CAD/CAM) solutions are available not only for chairside practice but also for creating inlays, crowns, fixed partial dentures (FPDs), implant abutments, and other dental prostheses. CAD/CAM dental practice can be considered as the handling of devices and software processing for the almost automatic design and creation of dental restorations. However, dentists who want to use dental CAD/CAM systems often do not have enough information to understand the variations offered by such technology practice. Knowledge of the random and systematic errors in accuracy with CAD/CAM systems can help to achieve successful restorations with this technology, and help with the purchasing of a CAD/CAM system that meets the clinical needs of restoration. This article provides a mechanical engineering viewpoint of the accuracy of CAD/ CAM systems, to help dentists understand the impact of this technology on restoration accuracy.

  7. [A computer aided design approach of all-ceramics abutment for maxilla central incisor].

    PubMed

    Sun, Yu-chun; Zhao, Yi-jiao; Wang, Yong; Han, Jing-yun; Lin, Ye; Lü, Pei-jun

    2010-10-01

    To establish the computer aided design (CAD) software platform of individualized abutment for the maxilla central incisor. Three-dimentional data of the incisor was collected by scanning and geometric transformation. Data mainly included the occlusal part of the healing abutment, the location carinae of the bedpiece, the occlusal 1/3 part of the artificial gingiva's inner surface, and so on. The all-ceramic crown designed in advanced was "virtual cutback" to get the original data of the abutment's supragingival part. The abutment's in-gum part was designed to simulate the individual natural tooth root. The functions such as "data offset", "bi-rail sweep surface" and "loft surface" were used in the process of CAD. The CAD route of the individualized all-ceramic abutment was set up. The functions and application methods were decided and the complete CAD process was realized. The software platform was basically set up according to the requests of the dental clinic.

  8. Resin-composite blocks for dental CAD/CAM applications.

    PubMed

    Ruse, N D; Sadoun, M J

    2014-12-01

    Advances in digital impression technology and manufacturing processes have led to a dramatic paradigm shift in dentistry and to the widespread use of computer-aided design/computer-aided manufacturing (CAD/CAM) in the fabrication of indirect dental restorations. Research and development in materials suitable for CAD/CAM applications are currently the most active field in dental materials. Two classes of materials are used in the production of CAD/CAM restorations: glass-ceramics/ceramics and resin composites. While glass-ceramics/ceramics have overall superior mechanical and esthetic properties, resin-composite materials may offer significant advantages related to their machinability and intra-oral reparability. This review summarizes recent developments in resin-composite materials for CAD/CAM applications, focusing on both commercial and experimental materials. © International & American Associations for Dental Research.

  9. TARDEC FIXED HEEL POINT (FHP): DRIVER CAD ACCOMMODATION MODEL VERIFICATION REPORT

    DTIC Science & Technology

    2017-11-09

    SUPPLEMENTARY NOTES N/A 14. ABSTRACT Easy-to-use Computer-Aided Design (CAD) tools, known as accommodation models, are needed by the ground vehicle... designers when developing the interior workspace for the occupant. The TARDEC Fixed Heel Point (FHP): Driver CAD Accommodation Model described in this...is intended to provide the composite boundaries representing the body of the defined target design population, including posture prediction

  10. Longitudinal Study of Factors Impacting the Implementation of Notebook Computer Based CAD Instruction

    ERIC Educational Resources Information Center

    Goosen, Richard F.

    2009-01-01

    This study provides information for higher education leaders that have or are considering conducting Computer Aided Design (CAD) instruction using student owned notebook computers. Survey data were collected during the first 8 years of a pilot program requiring engineering technology students at a four year public university to acquire a notebook…

  11. Fracture resistance of computer-aided design and computer-aided manufacturing ceramic crowns cemented on solid abutments.

    PubMed

    Stona, Deborah; Burnett, Luiz Henrique; Mota, Eduardo Gonçalves; Spohr, Ana Maria

    2015-07-01

    Because no information was found in the dental literature regarding the fracture resistance of all-ceramic crowns using CEREC (Sirona) computer-aided design and computer-aided manufacturing (CAD-CAM) system on solid abutments, the authors conducted a study. Sixty synOcta (Straumann) implant replicas and regular neck solid abutments were embedded in acrylic resin and randomly assigned (n = 20 per group). Three types of ceramics were used: feldspathic, CEREC VITABLOCS Mark II (VITA); leucite, IPS Empress CAD (Ivoclar Vivadent); and lithium disilicate, IPS e.max CAD (Ivoclar Vivadent). The crowns were fabricated by the CEREC CAD-CAM system. After receiving glaze, the crowns were cemented with RelyX U200 (3M ESPE) resin cement under load of 1 kilogram. For each ceramic, one-half of the specimens were subjected to the fracture resistance testing in a universal testing machine with a crosshead speed of 1 millimeter per minute, and the other half were subjected to the fractured resistance testing after 1,000,000 cyclic fatigue loading at 100 newtons. According to a 2-way analysis of variance, the interaction between the material and mechanical cycling was significant (P = .0001). According to a Tukey test (α = .05), the fracture resistance findings with or without cyclic fatigue loading were as follows, respectively: CEREC VITABLOCKS Mark II (405 N/454 N) was statistically lower than IPS Empress CAD (1169 N/1240 N) and IPS e.max CAD (1378 N/1025 N) (P < .05). The IPS Empress CAD and IPS e.max CAD did not differ statistically (P > .05). According to a t test, there was no statistical difference in the fracture resistance with and without cyclic fatigue loading for CEREC VITABLOCS Mark II and IPS Empress CAD (P > .05). For IPS e.max CAD, the fracture resistance without cyclic fatigue loading was statistically superior to that obtained with cyclic fatigue loading (P < .05). The IPS Empress CAD and IPS e.max CAD showed higher fracture resistance compared with CEREC VITABLOCS Mark II. The cyclic fatigue loading negatively influenced only IPS e.max CAD. The CEREC VITABLOCS Mark II, IPS Empress CAD, and IPS e.max CAD ceramic crowns cemented on solid abutments showed sufficient resistance to withstand normal chewing forces. Copyright © 2015 American Dental Association. Published by Elsevier Inc. All rights reserved.

  12. Microwave processing of a dental ceramic used in computer-aided design/computer-aided manufacturing.

    PubMed

    Pendola, Martin; Saha, Subrata

    2015-01-01

    Because of their favorable mechanical properties and natural esthetics, ceramics are widely used in restorative dentistry. The conventional ceramic sintering process required for their use is usually slow, however, and the equipment has an elevated energy consumption. Sintering processes that use microwaves have several advantages compared to regular sintering: shorter processing times, lower energy consumption, and the capacity for volumetric heating. The objective of this study was to test the mechanical properties of a dental ceramic used in computer-aided design/computer-aided manufacturing (CAD/CAM) after the specimens were processed with microwave hybrid sintering. Density, hardness, and bending strength were measured. When ceramic specimens were sintered with microwaves, the processing times were reduced and protocols were simplified. Hardness was improved almost 20% compared to regular sintering, and flexural strength measurements suggested that specimens were approximately 50% stronger than specimens sintered in a conventional system. Microwave hybrid sintering may preserve or improve the mechanical properties of dental ceramics designed for CAD/CAM processing systems, reducing processing and waiting times.

  13. [Three-dimensional computer aided design for individualized post-and-core restoration].

    PubMed

    Gu, Xiao-yu; Wang, Ya-ping; Wang, Yong; Lü, Pei-jun

    2009-10-01

    To develop a method of three-dimensional computer aided design (CAD) of post-and-core restoration. Two plaster casts with extracted natural teeth were used in this study. The extracted teeth were prepared and scanned using tomography method to obtain three-dimensional digitalized models. According to the basic rules of post-and-core design, posts, cores and cavity surfaces of the teeth were designed using the tools for processing point clouds, curves and surfaces on the forward engineering software of Tanglong prosthodontic system. Then three-dimensional figures of the final restorations were corrected according to the configurations of anterior teeth, premolars and molars respectively. Computer aided design of 14 post-and-core restorations were finished, and good fitness between the restoration and the three-dimensional digital models were obtained. Appropriate retention forms and enough spaces for the full crown restorations can be obtained through this method. The CAD of three-dimensional figures of the post-and-core restorations can fulfill clinical requirements. Therefore they can be used in computer-aided manufacture (CAM) of post-and-core restorations.

  14. Designers Workbench: Towards Real-Time Immersive Modeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuester, F; Duchaineau, M A; Hamann, B

    2001-10-03

    This paper introduces the DesignersWorkbench, a semi-immersive virtual environment for two-handed modeling, sculpting and analysis tasks. The paper outlines the fundamental tools, design metaphors and hardware components required for an intuitive real-time modeling system. As companies focus on streamlining productivity to cope with global competition, the migration to computer-aided design (CAD), computer-aided manufacturing (CAM), and computer-aided engineering (CAE) systems has established a new backbone of modern industrial product development. However, traditionally a product design frequently originates from a clay model that, after digitization, forms the basis for the numerical description of CAD primitives. The DesignersWorkbench aims at closing this technologymore » or ''digital gap'' experienced by design and CAD engineers by transforming the classical design paradigm into its filly integrated digital and virtual analog allowing collaborative development in a semi-immersive virtual environment. This project emphasizes two key components from the classical product design cycle: freeform modeling and analysis. In the freeform modeling stage, content creation in the form of two-handed sculpting of arbitrary objects using polygonal, volumetric or mathematically defined primitives is emphasized, whereas the analysis component provides the tools required for pre- and post-processing steps for finite element analysis tasks applied to the created models.« less

  15. A Case Study in CAD Design Automation

    ERIC Educational Resources Information Center

    Lowe, Andrew G.; Hartman, Nathan W.

    2011-01-01

    Computer-aided design (CAD) software and other product life-cycle management (PLM) tools have become ubiquitous in industry during the past 20 years. Over this time they have continuously evolved, becoming programs with enormous capabilities, but the companies that use them have not evolved their design practices at the same rate. Due to the…

  16. Microhardness evaluations of CAD/CAM ceramics irradiated with CO2 or Nd:YAP laser

    PubMed Central

    Rocca, Jean Paul; Fornaini, Carlo; Medioni, Etienne; Brulat-Bouchard, Nathalie

    2017-01-01

    Background and aims The aim of this study was to measure the microhardness values of irradiated computer-aided design/computer-aided manufacturing (CAD/CAM) ceramics surfaces before and after thermal treatment. Materials and Methods Sixty CAD/CAM ceramic discs were prepared and grouped by material, i.e. lithium disilicate ceramic (Emax CAD) and zirconia ceramic (Emax ZirCAD). Laser irradiation at the material surface was performed with a carbon dioxide laser at 5 Watt (W) or 10 W power in continuous mode (CW mode), or with a neodymium:yttrium aluminum perovskite (Nd:YAP) laser at 10 W on graphite and non-graphite surfaces. Vickers hardness was tested at 0.3 kgf for lithium disilicate and 1 kgf for zirconia. Results Emax CAD irradiated with CO2 at 5 W increased microhardness by 6.32 GPa whereas Emax ZirCAD irradiated with Nd:YAP decreased microhardness by 17.46 GPa. Conclusion CO2 laser effectively increases the microhardness of lithium disilicate ceramics (Emax CAD). PMID:28740324

  17. A paradigm shift in orthognathic surgery? A comparison of navigation, computer-aided designed/computer-aided manufactured splints, and "classic" intermaxillary splints to surgical transfer of virtual orthognathic planning.

    PubMed

    Zinser, Max J; Sailer, Hermann F; Ritter, Lutz; Braumann, Bert; Maegele, Marc; Zöller, Joachim E

    2013-12-01

    Advances in computers and imaging have permitted the adoption of 3-dimensional (3D) virtual planning protocols in orthognathic surgery, which may allow a paradigm shift when the virtual planning can be transferred properly. The purpose of this investigation was to compare the versatility and precision of innovative computer-aided designed and computer-aided manufactured (CAD/CAM) surgical splints, intraoperative navigation, and "classic" intermaxillary occlusal splints for surgical transfer of virtual orthognathic planning. The protocols consisted of maxillofacial imaging, diagnosis, virtual orthognathic planning, and surgical planning transfer using newly designed CAD/CAM splints (approach A), navigation (approach B), and intermaxillary occlusal splints (approach C). In this prospective observational study, all patients underwent bimaxillary osteotomy. Eight patients were treated using approach A, 10 using approach B, and 12 using approach C. These techniques were evaluated by applying 13 hard and 7 soft tissue parameters to compare the virtual orthognathic planning (T0) with the postoperative result (T1) using 3D cephalometry and image fusion (ΔT1 vs T0). The highest precision (ΔT1 vs T0) for the maxillary planning transfer was observed with CAD/CAM splints (<0.23 mm; P > .05) followed by surgical "waferless" navigation (<0.61 mm, P < .05) and classic intermaxillary occlusal splints (<1.1 mm; P < .05). Only the innovative CAD/CAM splints kept the condyles in their central position in the temporomandibular joint. However, no technique enables a precise prediction of the mandible and soft tissue. CAD/CAM splints and surgical navigation provide a reliable, innovative, and precise approach for the transfer of virtual orthognathic planning. These computer-assisted techniques may offer an alternate approach to the use of classic intermaxillary occlusal splints. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Gathering Empirical Evidence Concerning Links between Computer Aided Design (CAD) and Creativity

    ERIC Educational Resources Information Center

    Musta'amal, Aede Hatib; Norman, Eddie; Hodgson, Tony

    2009-01-01

    Discussion is often reported concerning potential links between computer-aided designing and creativity, but there is a lack of systematic enquiry to gather empirical evidence concerning such links. This paper reports an indication of findings from other research studies carried out in contexts beyond general education that have sought evidence…

  19. Computer aided design of monolithic microwave and millimeter wave integrated circuits and subsystems

    NASA Astrophysics Data System (ADS)

    Ku, Walter H.; Gang, Guan-Wan; He, J. Q.; Ichitsubo, I.

    1988-05-01

    This final technical report presents results on the computer aided design of monolithic microwave and millimeter wave integrated circuits and subsystems. New results include analytical and computer aided device models of GaAs MESFETs and HEMTs or MODFETs, new synthesis techniques for monolithic feedback and distributed amplifiers and a new nonlinear CAD program for MIMIC called CADNON. This program incorporates the new MESFET and HEMT model and has been successfully applied to the design of monolithic millimeter-wave mixers.

  20. Usability Studies in Virtual and Traditional Computer Aided Design Environments for Fault Identification

    DTIC Science & Technology

    2017-08-08

    Usability Studies In Virtual And Traditional Computer Aided Design Environments For Fault Identification Dr. Syed Adeel Ahmed, Xavier University...virtual environment with wand interfaces compared directly with a workstation non-stereoscopic traditional CAD interface with keyboard and mouse. In...the differences in interaction when compared with traditional human computer interfaces. This paper provides analysis via usability study methods

  1. [Influence of coping material selection and porcelain firing on marginal and internal fit of computer-aided design/computer- aided manufacturing of zirconia and titanium ceramic implant-supported crowns].

    PubMed

    Cuiling, Liu; Liyuan, Yang; Xu, Gao; Hong, Shang

    2016-06-01

    This study aimed to investigate the influence of coping material and porcelain firing on the marginal and internal fit of computer-aided design/computer-aided manufacturing (CAD/CAM) of zirconia ceramic implant- and titanium ceramic implant-supported crowns. Zirconia ceramic implant (group A, n = 8) and titanium metal ceramic implant-supported crowns (group B, n = 8) were produced from copings using the CAD/CAM system. The marginal and internal gaps of the copings and crowns were measured by using a light-body silicone replica technique combined with micro-computed tomography scanning to obtain a three-dimensional image. Marginal gap (MG), horizontal marginal discrepancy (HMD), and axial wall (AW) were measured. Statistical analyses were performed using SPSS 17.0. Prior to porcelain firing, the measurements for MG, HMD, and AW of copings in group A were significantly larger than those in group B (P < 0.05). After porcelain firing, the measurements for MG of crowns in group A were smaller than those in group B (P < 0.05), whereas HMD and AW showed no significant difference between the two groups (P > 0.05). Porcelain firing significantly reduced MG (P < 0.05) in group A but significantly increased MG, HMD, and AW in group B (P < 0.05) HMD and AW were not influenced by porcelain firing in group A (P > 0.05). The marginal fits of CAD/CAM zirconia ceramic implant-supported crowns were superior to those of CAD/CAM titanium ceramic-supported crowns. The fits of both the CAD/CAM zirconia ceramic implant- and titanium ceramic implant-supported crowns were obviously influenced by porcelain firing.

  2. Combined Stereophotogrammetry and Laser-Sintered, Computer-Aided Milling Framework for an Implant-Supported Mandibular Prosthesis: A Case History Report.

    PubMed

    Suarez, Maria J; Paisal, Iria; Rodriguez-Alonso, Veronica; Lopez-Suarez, Carlos

    This study compared the marginal gaps of computer-aided design/computer-aided manufacture (CAD/CAM)-fabricated all-ceramic crowns constructed from scanned impressions and models and with two different occlusal reduction designs. Two typodont mandibular first molars were prepared to receive CAD/CAM-fabricated all-ceramic crowns. Both molars were prepared to ideal crown reduction, the first with anatomical occlusal reduction (AOR) and the second with completely flat occlusal reduction (FOR). Nine polyvinyl siloxane impressions (PVS) were taken, and nine stone replicas fabricated for each preparation. All impressions and stone models were scanned using a laser scanner (Planmeca Planscan, E4D technologies), and 36 lithium disilicate (IPS e.max CAD) crowns were milled. The marginal gap was measured in four locations using a light stereomicroscope. Crowns constructed from preparations with both occlusal reduction designs demonstrated similar marginal gaps (FOR = 97.98; AOR = 89.12; P = .739). However, all crowns constructed from scanned impressions presented significantly larger marginal gaps than the crowns fabricated from scanned models (impressions = 109.26; models = 77.84; P = .002). Scanning stone models produced all-ceramic crowns with significantly smaller marginal gaps than scanning impressions, irrespective of the occlusal reduction design.

  3. Productivity increase through implementation of CAD/CAE workstation

    NASA Technical Reports Server (NTRS)

    Bromley, L. K.

    1985-01-01

    The tracking and communication division computer aided design/computer aided engineering system is now operational. The system is utilized in an effort to automate certain tasks that were previously performed manually. These tasks include detailed test configuration diagrams of systems under certification test in the ESTL, floorplan layouts of future planned laboratory reconfigurations, and other graphical documentation of division activities. The significant time savings achieved with this CAD/CAE system are examined: (1) input of drawings and diagrams; (2) editing of initial drawings; (3) accessibility of the data; and (4) added versatility. It is shown that the Applicon CAD/CAE system, with its ease of input and editing, the accessibility of data, and its added versatility, has made more efficient many of the necessary but often time-consuming tasks associated with engineering design and testing.

  4. Viewing CAD Drawings on the Internet

    ERIC Educational Resources Information Center

    Schwendau, Mark

    2004-01-01

    Computer aided design (CAD) has been producing 3-D models for years. AutoCAD software is frequently used to create sophisticated 3-D models. These CAD files can be exported as 3DS files for import into Autodesk's 3-D Studio Viz. In this program, the user can render and modify the 3-D model before exporting it out as a WRL (world file hyperlinked)…

  5. Development and Verification of Body Armor Target Geometry Created Using Computed Tomography Scans

    DTIC Science & Technology

    2017-07-13

    designated by other authorized documents. Citation of manufacturer’s or trade names does not constitute an official endorsement or approval of...modeling consisted of manual measurement of armor systems and translating those measurements to computer-aided design geometry, which can be tedious and...computer-aided design (CAD) human geometry model (referred to throughout as ORCA man) that is used in the Operational Requirement-based Casualty Assessment

  6. Manufacturing Methods and Technology Project Summary Reports

    DTIC Science & Technology

    1985-06-01

    Computer -Aided Design (CAD)/ Computer -Aided Manufacturing (CAM) Process for the Production of Cold Forged Gears Project 483 6121 - Robotic Welding and...Caliber Projectile Bodies Project 682 8370 - Automatic Inspection and 1-I1 Process Control of Weapons Parts Manufacturing METALS Project 181 7285 - Cast...designed for use on each project. Experience suggested that a general purpose computer interface might be designed that could be used on any project

  7. Update of patient-specific maxillofacial implant.

    PubMed

    Owusu, James A; Boahene, Kofi

    2015-08-01

    Patient-specific implant (PSI) is a personalized approach to reconstructive and esthetic surgery. This is particularly useful in maxillofacial surgery in which restoring the complex three-dimensional (3D) contour can be quite challenging. In certain situations, the best results can only be achieved with implants custom-made to fit a particular need. Significant progress has been made over the past decade in the design and manufacture of maxillofacial PSIs. Computer-aided design (CAD)/computer-aided manufacturing (CAM) technology is rapidly advancing and has provided new options for fabrication of PSIs with better precision. Maxillofacial PSIs can now be designed using preoperative imaging data as input into CAD software. The designed implant is then fabricated using a CAM technique such as 3D printing. This approach increases precision and decreases or completely eliminates the need for intraoperative modification of implants. The use of CAD/CAM-produced PSIs for maxillofacial reconstruction and augmentation can significantly improve contour outcomes and decrease operating time. CAD/CAM technology allows timely and precise fabrication of maxillofacial PSIs. This approach is gaining increasing popularity in maxillofacial reconstructive surgery. Continued advances in CAD technology and 3D printing are bound to improve the cost-effectiveness and decrease the production time of maxillofacial PSIs.

  8. Classroom Experiences in an Engineering Design Graphics Course with a CAD/CAM Extension.

    ERIC Educational Resources Information Center

    Barr, Ronald E.; Juricic, Davor

    1997-01-01

    Reports on the development of a new CAD/CAM laboratory experience for an Engineering Design Graphics (EDG) course. The EDG curriculum included freehand sketching, introduction to Computer-Aided Design and Drafting (CADD), and emphasized 3-D solid modeling. Reviews the project and reports on the testing of the new laboratory components which were…

  9. Secondary Maxillary and Orbital Floor Reconstruction With a Free Scapular Flap Using Cutting and Fixation Guides Created by Computer-Aided Design/Computer-Aided Manufacturing.

    PubMed

    Morita, Daiki; Numajiri, Toshiaki; Tsujiko, Shoko; Nakamura, Hiroko; Yamochi, Ryo; Sowa, Yoshihiro; Yasuda, Makoto; Hirano, Shigeru

    2017-11-01

    Computer-aided design/computer-aided manufacturing (CAD/CAM) guides are now widely used in maxillofacial reconstruction. However, there are few reports of CAD/CAM guides being used for scapular flaps. The authors performed the secondary maxillary and orbital floor reconstruction using a free latissimus dorsi muscle, cutaneous tissue, and scapular flap designed using CAD/CAM techniques in a 72-year-old man who had undergone partial maxillectomy four years previously. The patient had diplopia, the vertical dystopia of eye position, and a large oral-nasal-cutaneous fistula. After the operation, the authors confirmed that the deviation between the postoperative and preoperative planning three-dimensional images was less than 2 mm. Because scapular guides require 3 cutting surfaces, the shape of the scapular guide is more complex than that of a conventional fibular guide. In orbital floor reconstruction, the use of a CAM technique such as that used to manufacture the authors' fixation guide is as necessary for accurate, safe, and easy reconstruction as is preoperative CAD planning. The production of a fixation guide as well as a cutting guide is particularly useful because it is difficult to determine the angle for reconstructing the orbital floor by freehand techniques. In this case, the orbital floor was reconstructed based on a mirror image of the healthy side to avoid overcompression of the orbital tissue. Although the patient's vertical dystopia of eye position was improved, diplopia was not improved because, for greater safety, the authors did not plan overcorrection of the orbital volume.

  10. Using CAD Programs in CAL.

    ERIC Educational Resources Information Center

    Boardman, D.

    1979-01-01

    Practical experience has shown that computer aided design programs can provide an invaluable aid in the learning process when integrated into the syllabus in lecture and laboratory periods. This should be a major area of future development of computer assisted learning in engineering education. (Author/CMV)

  11. Experimental CAD Course Uses Low-Cost Systems.

    ERIC Educational Resources Information Center

    Wohlers, Terry

    1984-01-01

    Describes the outstanding results obtained when a department of industrial sciences used special software on microcomputers to teach computer-aided design (CAD) as an alternative to much more expensive equipment. The systems used and prospects for the future are also considered. (JN)

  12. Platform-independent method for computer aided schematic drawings

    DOEpatents

    Vell, Jeffrey L [Slingerlands, NY; Siganporia, Darius M [Clifton Park, NY; Levy, Arthur J [Fort Lauderdale, FL

    2012-02-14

    A CAD/CAM method is disclosed for a computer system to capture and interchange schematic drawing and associated design information. The schematic drawing and design information are stored in an extensible, platform-independent format.

  13. Program Evolves from Basic CAD to Total Manufacturing Experience

    ERIC Educational Resources Information Center

    Cassola, Joel

    2011-01-01

    Close to a decade ago, John Hersey High School (JHHS) in Arlington Heights, Illinois, made a transition from a traditional classroom-based pre-engineering program. The new program is geared towards helping students understand the entire manufacturing process. Previously, a JHHS student would design a project in computer-aided design (CAD) software…

  14. Correlating Trainee Attributes to Performance in 3D CAD Training

    ERIC Educational Resources Information Center

    Hamade, Ramsey F.; Artail, Hassan A.; Sikstrom, Sverker

    2007-01-01

    Purpose: The purpose of this exploratory study is to identify trainee attributes relevant for development of skills in 3D computer-aided design (CAD). Design/methodology/approach: Participants were trained to perform cognitive tasks of comparable complexity over time. Performance data were collected on the time needed to construct test models, and…

  15. Digital model as an alternative to plaster model in assessment of space analysis

    PubMed Central

    Kumar, A. Anand; Phillip, Abraham; Kumar, Sathesh; Rawat, Anuradha; Priya, Sakthi; Kumaran, V.

    2015-01-01

    Introduction: Digital three-dimensional models are widely used for orthodontic diagnosis. The purpose of this study was to appraise the accuracy of digital models obtained from computer-aided design/computer-aided manufacturing (CAD/CAM) and cone-beam computed tomography (CBCT) for tooth-width measurements and the Bolton analysis. Materials and Methods: Digital models (CAD/CAM, CBCT) and plaster model were made for each of 50 subjects. Tooth-width measurements on the digital models (CAD/CAM, CBCT) were compared with those on the corresponding plaster models. The anterior and overall Bolton ratios were calculated for each participant and for each method. The paired t-test was applied to determine the validity. Results: Tooth-width measurements, anterior, and overall Bolton ratio of digital models of CAD/CAM and CBCT did not differ significantly from those on the plaster models. Conclusion: Hence, both CBCT and CAD/CAM are trustable and promising technique that can replace plaster models due to its overwhelming advantages. PMID:26538899

  16. How to Quickly Import CAD Geometry into Thermal Desktop

    NASA Technical Reports Server (NTRS)

    Wright, Shonte; Beltran, Emilio

    2002-01-01

    There are several groups at JPL (Jet Propulsion Laboratory) that are committed to concurrent design efforts, two are featured here. Center for Space Mission Architecture and Design (CSMAD) enables the practical application of advanced process technologies in JPL's mission architecture process. Team I functions as an incubator for projects that are in the Discovery, and even pre-Discovery proposal stages. JPL's concurrent design environment is to a large extent centered on the CAD (Computer Aided Design) file. During concurrent design sessions CAD geometry is ported to other more specialized engineering design packages.

  17. Society for College Science Teachers: High Technology.

    ERIC Educational Resources Information Center

    Menefee, Robert

    1983-01-01

    Presents findings of a study group on high technology charged with determining a definition, assessing current educational response, and examining implications for the future. Topics addressed include: super-techs; computer-aided design/computer-aided manufacture (CAD/CAM); structural unemployment; a two-plus-two curriculum; and educational…

  18. [Veneer computer aided design based on reverse engineering technology].

    PubMed

    Liu, Ming-li; Chen, Xiao-dong; Wang, Yong

    2012-03-01

    To explore the computer aided design (CAD) method of veneer restoration, and to assess if the solution can help prosthesis meet morphology esthetics standard. A volunteer's upper right central incisor needed to be restored with veneer. Super hard stone models of patient's dentition (before and after tooth preparation) were scanned with the three-dimensional laser scanner. The veneer margin was designed as butt-to-butt type. The veneer was constructed using reverse engineering (RE) software. The technique guideline of veneers CAD was explore based on RE software, and the veneers was smooth, continuous and symmetrical, which met esthetics construction needs. It was a feasible method to reconstruct veneer restoration based on RE technology.

  19. Computer Aided Drafting. Instructor's Guide.

    ERIC Educational Resources Information Center

    Henry, Michael A.

    This guide is intended for use in introducing students to the operation and applications of computer-aided drafting (CAD) systems. The following topics are covered in the individual lessons: understanding CAD (CAD versus traditional manual drafting and care of software and hardware); using the components of a CAD system (primary and other input…

  20. Evaluation of computer-aided detection and diagnosis systems.

    PubMed

    Petrick, Nicholas; Sahiner, Berkman; Armato, Samuel G; Bert, Alberto; Correale, Loredana; Delsanto, Silvia; Freedman, Matthew T; Fryd, David; Gur, David; Hadjiiski, Lubomir; Huo, Zhimin; Jiang, Yulei; Morra, Lia; Paquerault, Sophie; Raykar, Vikas; Samuelson, Frank; Summers, Ronald M; Tourassi, Georgia; Yoshida, Hiroyuki; Zheng, Bin; Zhou, Chuan; Chan, Heang-Ping

    2013-08-01

    Computer-aided detection and diagnosis (CAD) systems are increasingly being used as an aid by clinicians for detection and interpretation of diseases. Computer-aided detection systems mark regions of an image that may reveal specific abnormalities and are used to alert clinicians to these regions during image interpretation. Computer-aided diagnosis systems provide an assessment of a disease using image-based information alone or in combination with other relevant diagnostic data and are used by clinicians as a decision support in developing their diagnoses. While CAD systems are commercially available, standardized approaches for evaluating and reporting their performance have not yet been fully formalized in the literature or in a standardization effort. This deficiency has led to difficulty in the comparison of CAD devices and in understanding how the reported performance might translate into clinical practice. To address these important issues, the American Association of Physicists in Medicine (AAPM) formed the Computer Aided Detection in Diagnostic Imaging Subcommittee (CADSC), in part, to develop recommendations on approaches for assessing CAD system performance. The purpose of this paper is to convey the opinions of the AAPM CADSC members and to stimulate the development of consensus approaches and "best practices" for evaluating CAD systems. Both the assessment of a standalone CAD system and the evaluation of the impact of CAD on end-users are discussed. It is hoped that awareness of these important evaluation elements and the CADSC recommendations will lead to further development of structured guidelines for CAD performance assessment. Proper assessment of CAD system performance is expected to increase the understanding of a CAD system's effectiveness and limitations, which is expected to stimulate further research and development efforts on CAD technologies, reduce problems due to improper use, and eventually improve the utility and efficacy of CAD in clinical practice.

  1. Evaluation of computer-aided detection and diagnosis systemsa)

    PubMed Central

    Petrick, Nicholas; Sahiner, Berkman; Armato, Samuel G.; Bert, Alberto; Correale, Loredana; Delsanto, Silvia; Freedman, Matthew T.; Fryd, David; Gur, David; Hadjiiski, Lubomir; Huo, Zhimin; Jiang, Yulei; Morra, Lia; Paquerault, Sophie; Raykar, Vikas; Samuelson, Frank; Summers, Ronald M.; Tourassi, Georgia; Yoshida, Hiroyuki; Zheng, Bin; Zhou, Chuan; Chan, Heang-Ping

    2013-01-01

    Computer-aided detection and diagnosis (CAD) systems are increasingly being used as an aid by clinicians for detection and interpretation of diseases. Computer-aided detection systems mark regions of an image that may reveal specific abnormalities and are used to alert clinicians to these regions during image interpretation. Computer-aided diagnosis systems provide an assessment of a disease using image-based information alone or in combination with other relevant diagnostic data and are used by clinicians as a decision support in developing their diagnoses. While CAD systems are commercially available, standardized approaches for evaluating and reporting their performance have not yet been fully formalized in the literature or in a standardization effort. This deficiency has led to difficulty in the comparison of CAD devices and in understanding how the reported performance might translate into clinical practice. To address these important issues, the American Association of Physicists in Medicine (AAPM) formed the Computer Aided Detection in Diagnostic Imaging Subcommittee (CADSC), in part, to develop recommendations on approaches for assessing CAD system performance. The purpose of this paper is to convey the opinions of the AAPM CADSC members and to stimulate the development of consensus approaches and “best practices” for evaluating CAD systems. Both the assessment of a standalone CAD system and the evaluation of the impact of CAD on end-users are discussed. It is hoped that awareness of these important evaluation elements and the CADSC recommendations will lead to further development of structured guidelines for CAD performance assessment. Proper assessment of CAD system performance is expected to increase the understanding of a CAD system's effectiveness and limitations, which is expected to stimulate further research and development efforts on CAD technologies, reduce problems due to improper use, and eventually improve the utility and efficacy of CAD in clinical practice. PMID:23927365

  2. Computer-aided Classification of Mammographic Masses Using Visually Sensitive Image Features

    PubMed Central

    Wang, Yunzhi; Aghaei, Faranak; Zarafshani, Ali; Qiu, Yuchen; Qian, Wei; Zheng, Bin

    2017-01-01

    Purpose To develop a new computer-aided diagnosis (CAD) scheme that computes visually sensitive image features routinely used by radiologists to develop a machine learning classifier and distinguish between the malignant and benign breast masses detected from digital mammograms. Methods An image dataset including 301 breast masses was retrospectively selected. From each segmented mass region, we computed image features that mimic five categories of visually sensitive features routinely used by radiologists in reading mammograms. We then selected five optimal features in the five feature categories and applied logistic regression models for classification. A new CAD interface was also designed to show lesion segmentation, computed feature values and classification score. Results Areas under ROC curves (AUC) were 0.786±0.026 and 0.758±0.027 when to classify mass regions depicting on two view images, respectively. By fusing classification scores computed from two regions, AUC increased to 0.806±0.025. Conclusion This study demonstrated a new approach to develop CAD scheme based on 5 visually sensitive image features. Combining with a “visual aid” interface, CAD results may be much more easily explainable to the observers and increase their confidence to consider CAD generated classification results than using other conventional CAD approaches, which involve many complicated and visually insensitive texture features. PMID:27911353

  3. Chairside Computer-Aided Design/Computer-Aided Manufacture All-Ceramic Crown and Endocrown Restorations: A 7-Year Survival Rate Study.

    PubMed

    Fages, Michel; Raynal, Jacques; Tramini, Paul; Cuisinier, Frédéric Jg; Durand, Jean-Cédric

    The objective of the present study was to analyze the clinical outcomes of 447 monoblock ceramic chairside computer-aided design/computer-aided manufacture (CAD/CAM) reconstructions over a 7-year functional period. Of these reconstructions, 212 were peripheral crowns and 235 were endocrowns. The restorations were placed between 2003 and 2008 in a total of 323 patients. They were created using a chairside CAD/CAM method and the same materials in all cases. All of the crowns were manufactured and glued during the same clinical session by the same practitioner. Data were descriptively analyzed and survival probabilities were calculated using Kaplan-Meier statistics. Of the 447 restorations, only 6 failures occurred, resulting in a success rate of 98.66%. All of the failures were the result of a partial ceramic fracture. Of the six ceramic fractures, five appeared on peripheral crowns and one on an endocrown. All fractures appeared in the first 24 months, including two in the first month. Log-rank test comparing incidence rates between crowns and endocrowns showed no significant differences (P = .08). This survival rate study reinforced the use of CAD/CAM full ceramic crowns and endocrowns on molars, showing a much more favorable survival rate for endocrowns.

  4. Using 3D Geometric Models to Teach Spatial Geometry Concepts.

    ERIC Educational Resources Information Center

    Bertoline, Gary R.

    1991-01-01

    An explanation of 3-D Computer Aided Design (CAD) usage to teach spatial geometry concepts using nontraditional techniques is presented. The software packages CADKEY and AutoCAD are described as well as their usefulness in solving space geometry problems. (KR)

  5. Alternatives for Saving and Viewing CAD Graphics for the Web.

    ERIC Educational Resources Information Center

    Harris, La Verne Abe; Sadowski, Mary A.

    2001-01-01

    Introduces some alternatives for preparing and viewing computer aided design (CAD) graphics for Internet output on a budget, without the fear of copyright infringement, and without having to go back to college to learn a complex graphic application. (Author/YDS)

  6. Management of CAD/CAM information: Key to improved manufacturing productivity

    NASA Technical Reports Server (NTRS)

    Fulton, R. E.; Brainin, J.

    1984-01-01

    A key element to improved industry productivity is effective management of CAD/CAM information. To stimulate advancements in this area, a joint NASA/Navy/Industry project designated Integrated Programs for Aerospace-Vehicle Design (IPAD) is underway with the goal of raising aerospace industry productivity through advancement of technology to integrate and manage information involved in the design and manufacturing process. The project complements traditional NASA/DOD research to develop aerospace design technology and the Air Force's Integrated Computer-Aided Manufacturing (ICAM) program to advance CAM technology. IPAD research is guided by an Industry Technical Advisory Board (ITAB) composed of over 100 repesentatives from aerospace and computer companies. The IPAD accomplishments to date in development of requirements and prototype software for various levels of company-wide CAD/CAM data management are summarized and plans for development of technology for management of distributed CAD/CAM data and information required to control future knowledge-based CAD/CAM systems are discussed.

  7. Product definition data interface

    NASA Technical Reports Server (NTRS)

    Birchfield, B.; Downey, P.

    1984-01-01

    The development and application of advanced Computer Aided Design/Computer Aided Manufacturing (CAD/CAM) technology in aerospace industry is discussed. New CAD/CAM capabilities provide the engineer and production worker with tools to produce better products and significantly improve productivity. This technology is expanding in all phases of engineering and manufacturing with large potential for improvements in productivity. The integration of CAD and CAM systematically to insure maximum utility throughout the U.S. Aerospace Industry, its large community of supporting suppliers, and the Department of Defense aircraft overhaul and repair facilities is outlined. The need for a framework for exchange of digital product definition data, which serves the function of the conventional engineering drawing is emphasized.

  8. Computer-aided design of microvasculature systems for use in vascular scaffold production.

    PubMed

    Mondy, William Lafayette; Cameron, Don; Timmermans, Jean-Pierre; De Clerck, Nora; Sasov, Alexander; Casteleyn, Christophe; Piegl, Les A

    2009-09-01

    In vitro biomedical engineering of intact, functional vascular networks, which include capillary structures, is a prerequisite for adequate vascular scaffold production. Capillary structures are necessary since they provide the elements and compounds for the growth, function and maintenance of 3D tissue structures. Computer-aided modeling of stereolithographic (STL) micro-computer tomographic (micro-CT) 3D models is a technique that enables us to mimic the design of vascular tree systems containing capillary beds, found in tissues. In our first paper (Mondy et al 2009 Tissue Eng. at press), using micro-CT, we studied the possibility of using vascular tissues to produce data capable of aiding the design of vascular tree scaffolding, which would help in the reverse engineering of a complete vascular tree system including capillary bed structures. In this paper, we used STL models of large datasets of computer-aided design (CAD) data of vascular structures which contained capillary structures that mimic those in the dermal layers of rabbit skin. Using CAD software we created from 3D STL models a bio-CAD design for the development of capillary-containing vascular tree scaffolding for skin. This method is designed to enhance a variety of therapeutic protocols including, but not limited to, organ and tissue repair, systemic disease mediation and cell/tissue transplantation therapy. Our successful approach to in vitro vasculogenesis will allow the bioengineering of various other types of 3D tissue structures, and as such greatly expands the potential applications of biomedical engineering technology into the fields of biomedical research and medicine.

  9. CAD/CAM/AM applications in the manufacture of dental appliances.

    PubMed

    Al Mortadi, Noor; Eggbeer, Dominic; Lewis, Jeffrey; Williams, Robert J

    2012-11-01

    The purposes of this study were to apply the latest developments in additive manufacturing (AM) construction and to evaluate the effectiveness of these computer-aided design and computer-aided manufacturing (CAD/CAM) techniques in the production of dental appliances. In addition, a new method of incorporating wire into a single build was developed. A scanner was used to capture 3-dimensional images of Class II Division 1 dental models that were translated onto a 2-dimensional computer screen. Andresen and sleep-apnea devices were designed in 3 dimensions by using FreeForm software (version 11; Geo Magics SensAble Group, Wilmington, Mass) and a phantom arm. The design was then exported and transferred to an AM machine for building. Copyright © 2012 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  10. A Prototype of CAD/CAM Education in the Community College.

    ERIC Educational Resources Information Center

    Kimmey, James R.

    Drawing upon Elgin Community College's (ECC's) 7-year history of program development and operation, this paper demonstrates how ECC, in cooperation with Northern Illinois Industries, Computervision Corporation, Mazak Corporation, and the Society of Manufacturing Engineers, established a Computer-Aided Design and Drafting/Computer-Aided Machining…

  11. PLM in the context of the maritime virtual education

    NASA Astrophysics Data System (ADS)

    Raicu, Alexandra; Oanta, Emil M.

    2016-12-01

    This paper presents new approaches regarding the use of Product Lifecycle Management concept to achieve knowledge integration of the academic disciplines in the maritime education context. The philosophy of the educational system is now changing faster worldwide and it is in a continuous developing process. There is a demand to develop modern educational facilities for CAD/CAE/CAM training of the future maritime engineers, which offers collaborative environments between the academic disciplines and the teachers. It is well known that the students must understand the importance of the connectivity between the academic disciplines and the computer aided methods to interface them. Thus, besides the basic knowledge and competences acquired from the CAD courses, students learn how to increase the design productivity, to create a parametric design, the original instruments of automatic design, 3D printing methods, how to interface the CAD/CAE/CAM applications. As an example, the Strength of Materials discipline briefly presents alternate computer aided methods to compute the geometrical characteristics of the cross sections using the CAD geometry, creation the free body diagrams and presentation the deflected shapes of various educational models, including the rotational effect when the forces are not applied in the shear center, using the results of the FEM applications. During the computer aided engineering academic disciplines, after the students design and analyze a virtual 3D model they can convert it into a physical object using 3D printing method. Constanta Maritime University offers a full understanding of the concept of Product Lifecycle Management, collaborative creation, management and dissemination.

  12. Unique CAD/CAM three-quarter crown restoration of a central incisor: a case report.

    PubMed

    Goldberg, Marvin B; Siegel, Sharon C; Rezakani, Niloufar

    2013-07-01

    Computer-aided design and computer-aided manufacturing (CAD/CAM) dentistry has been in use for more than 2 decades. Recent improvements in this technology have made CAD/CAM restorations a viable alternative for routine dental care. This technology is being taught in dental schools to prepare students for contemporary dental practice and is particularly useful in unique restorative situations that allow conservation of tooth structure. This case report describes the restoration of a central incisor that was previously restored with an unesthetic three-quarter gold crown. The tooth exhibited recurrent caries and an unaffected labial wall of supported enamel. A CAD/CAM three-quarter crown was planned to conserve tooth structure. After preparation, the tooth was scanned for a CAD/CAM crown in order to fabricate a ceramic restoration, which was then milled and bonded, producing an esthetic result. Typically, in cases of esthetic enhancement, a labial laminate restoration is fabricated, but in this situation, a different approach was necessary to make a design for the lingual surface of an anterior tooth.

  13. Effect of Premolar Axial Wall Height on Computer-Aided Design/Computer-Assisted Manufacture Crown Retention.

    PubMed

    Martin, Curt; Harris, Ashley; DuVall, Nicholas; Wajdowicz, Michael; Roberts, Howard Wayne

    2018-03-28

    To evaluate the effect of premolar axial wall height on the retention of adhesive, full-coverage, computer-aided design/computer-assisted manufacture (CAD/CAM) restorations. A total of 48 premolar teeth randomized into four groups (n = 12 per group) received all-ceramic CAD/CAM restorations with axial wall heights (AWH) of 3, 2, 1, and 0 mm and 16-degree total occlusal convergence (TOC). Specimens were restored with lithium disilicate material and cemented with self-adhesive resin cement. Specimens were loaded to failure after 24 hours. The 3- and 2-mm AWH specimens demonstrated significantly greater failure load. Failure analysis suggests a 2-mm minimum AWH for premolars with a TOC of 16 degrees. Adhesive technology may compensate for compromised AWH.

  14. Development of a CAD Model Simplification Framework for Finite Element Analysis

    DTIC Science & Technology

    2012-01-01

    A. Senthil Kumar , and KH Lee. Automatic solid decomposition and reduction for non-manifold geometric model generation. Computer-Aided Design, 36(13...CAD/CAM: concepts, techniques, and applications. Wiley-interscience, 1995. [38] Avneesh Sud, Mark Foskey, and Dinesh Manocha. Homotopy-preserving

  15. Attitudes of Design Students toward Computer Usage in Design

    ERIC Educational Resources Information Center

    Pektas, Sule Tasli; Erkip, Feyzan

    2006-01-01

    The success of efforts to integrate technology with design education is largely affected by the attitudes of students toward technology. This paper presents the findings of a research on the attitudes of design students toward the use of computers in design and its correlates. Computer Aided Design (CAD) tools are the most widely used computer…

  16. CAD/CAM (Computer-Aided Design/Computer-Aided Manufacturing) Highlights.

    DTIC Science & Technology

    1984-10-01

    ATTN: AMCRE-C/Ms. Jean Lamb C dr, ATTN: ANCRM-P/Mr. Jerry Gibson Cdr, ATTN: AMCQA-E/Mr. Billings Cdr, ATTN: AMXAM-TL/Technical Library US Army...Sands Missile Range, ATTN: STEWS -TE-TL/Technical Library Cdr, US Military Academy, ATTN: LTC Lanse Leach - - . Cdr, Yuma Proving Grounds, ATTN

  17. GPU-accelerated depth map generation for X-ray simulations of complex CAD geometries

    NASA Astrophysics Data System (ADS)

    Grandin, Robert J.; Young, Gavin; Holland, Stephen D.; Krishnamurthy, Adarsh

    2018-04-01

    Interactive x-ray simulations of complex computer-aided design (CAD) models can provide valuable insights for better interpretation of the defect signatures such as porosity from x-ray CT images. Generating the depth map along a particular direction for the given CAD geometry is the most compute-intensive step in x-ray simulations. We have developed a GPU-accelerated method for real-time generation of depth maps of complex CAD geometries. We preprocess complex components designed using commercial CAD systems using a custom CAD module and convert them into a fine user-defined surface tessellation. Our CAD module can be used by different simulators as well as handle complex geometries, including those that arise from complex castings and composite structures. We then make use of a parallel algorithm that runs on a graphics processing unit (GPU) to convert the finely-tessellated CAD model to a voxelized representation. The voxelized representation can enable heterogeneous modeling of the volume enclosed by the CAD model by assigning heterogeneous material properties in specific regions. The depth maps are generated from this voxelized representation with the help of a GPU-accelerated ray-casting algorithm. The GPU-accelerated ray-casting method enables interactive (> 60 frames-per-second) generation of the depth maps of complex CAD geometries. This enables arbitrarily rotation and slicing of the CAD model, leading to better interpretation of the x-ray images by the user. In addition, the depth maps can be used to aid directly in CT reconstruction algorithms.

  18. 3-D Geometric Modeling for the 21st Century.

    ERIC Educational Resources Information Center

    Ault, Holly K.

    1999-01-01

    Describes new geometric computer models used in contemporary computer-aided design (CAD) software including wire frame, surface, solid, and parametric models. Reviews their use in engineering design and discusses the impact of these new technologies on the engineering design graphics curriculum. (Author/CCM)

  19. CT Colonography with Computer-aided Detection: Recognizing the Causes of False-Positive Reader Results

    PubMed Central

    Dachman, Abraham H.; Wroblewski, Kristen; Vannier, Michael W.; Horne, John M.

    2014-01-01

    Computed tomography (CT) colonography is a screening modality used to detect colonic polyps before they progress to colorectal cancer. Computer-aided detection (CAD) is designed to decrease errors of detection by finding and displaying polyp candidates for evaluation by the reader. CT colonography CAD false-positive results are common and have numerous causes. The relative frequency of CAD false-positive results and their effect on reader performance on the basis of a 19-reader, 100-case trial shows that the vast majority of CAD false-positive results were dismissed by readers. Many CAD false-positive results are easily disregarded, including those that result from coarse mucosa, reconstruction, peristalsis, motion, streak artifacts, diverticulum, rectal tubes, and lipomas. CAD false-positive results caused by haustral folds, extracolonic candidates, diminutive lesions (<6 mm), anal papillae, internal hemorrhoids, varices, extrinsic compression, and flexural pseudotumors are almost always recognized and disregarded. The ileocecal valve and tagged stool are common sources of CAD false-positive results associated with reader false-positive results. Nondismissable CAD soft-tissue polyp candidates larger than 6 mm are another common cause of reader false-positive results that may lead to further evaluation with follow-up CT colonography or optical colonoscopy. Strategies for correctly evaluating CAD polyp candidates are important to avoid pitfalls from common sources of CAD false-positive results. ©RSNA, 2014 PMID:25384290

  20. Computer-aided linear-circuit design.

    NASA Technical Reports Server (NTRS)

    Penfield, P.

    1971-01-01

    Usually computer-aided design (CAD) refers to programs that analyze circuits conceived by the circuit designer. Among the services such programs should perform are direct network synthesis, analysis, optimization of network parameters, formatting, storage of miscellaneous data, and related calculations. The program should be embedded in a general-purpose conversational language such as BASIC, JOSS, or APL. Such a program is MARTHA, a general-purpose linear-circuit analyzer embedded in APL.

  1. A rule based computer aided design system

    NASA Technical Reports Server (NTRS)

    Premack, T.

    1986-01-01

    A Computer Aided Design (CAD) system is presented which supports the iterative process of design, the dimensional continuity between mating parts, and the hierarchical structure of the parts in their assembled configuration. Prolog, an interactive logic programming language, is used to represent and interpret the data base. The solid geometry representing the parts is defined in parameterized form using the swept volume method. The system is demonstrated with a design of a spring piston.

  2. Research on computer-aided design of modern marine power systems

    NASA Astrophysics Data System (ADS)

    Ding, Dongdong; Zeng, Fanming; Chen, Guojun

    2004-03-01

    To make the MPS (Marine Power System) design process more economical and easier, a new CAD scheme is brought forward which takes much advantage of VR (Virtual Reality) and AI (Artificial Intelligence) technologies. This CAD system can shorten the period of design and reduce the requirements on designers' experience in large scale. And some key issues like the selection of hardware and software of such a system are discussed.

  3. Creation of system of computer-aided design for technological objects

    NASA Astrophysics Data System (ADS)

    Zubkova, T. M.; Tokareva, M. A.; Sultanov, N. Z.

    2018-05-01

    Due to the competition in the market of process equipment, its production should be flexible, retuning to various product configurations, raw materials and productivity, depending on the current market needs. This process is not possible without CAD (computer-aided design). The formation of CAD begins with planning. Synthesizing, analyzing, evaluating, converting operations, as well as visualization and decision-making operations, can be automated. Based on formal description of the design procedures, the design route in the form of an oriented graph is constructed. The decomposition of the design process, represented by the formalized description of the design procedures, makes it possible to make an informed choice of the CAD component for the solution of the task. The object-oriented approach allows us to consider the CAD as an independent system whose properties are inherited from the components. The first step determines the range of tasks to be performed by the system, and a set of components for their implementation. The second one is the configuration of the selected components. The interaction between the selected components is carried out using the CALS standards. The chosen CAD / CAE-oriented approach allows creating a single model, which is stored in the database of the subject area. Each of the integration stages is implemented as a separate functional block. The transformation of the CAD model into the model of the internal representation is realized by the block of searching for the geometric parameters of the technological machine, in which the XML-model of the construction is obtained on the basis of the feature method from the theory of image recognition. The configuration of integrated components is divided into three consecutive steps: configuring tasks, components, interfaces. The configuration of the components is realized using the theory of "soft computations" using the Mamdani fuzzy inference algorithm.

  4. Comparative fracture strength analysis of Lava and Digident CAD/CAM zirconia ceramic crowns.

    PubMed

    Kwon, Taek-Ka; Pak, Hyun-Soon; Yang, Jae-Ho; Han, Jung-Suk; Lee, Jai-Bong; Kim, Sung-Hun; Yeo, In-Sung

    2013-05-01

    All-ceramic crowns are subject to fracture during function. To minimize this common clinical complication, zirconium oxide has been used as the framework for all-ceramic crowns. The aim of this study was to compare the fracture strengths of two computer-aided design/computer-aided manufacturing (CAD/CAM) zirconia crown systems: Lava and Digident. Twenty Lava CAD/CAM zirconia crowns and twenty Digident CAD/CAM zirconia crowns were fabricated. A metal die was also duplicated from the original prepared tooth for fracture testing. A universal testing machine was used to determine the fracture strength of the crowns. THE MEAN FRACTURE STRENGTHS WERE AS FOLLOWS: 54.9 ± 15.6 N for the Lava CAD/CAM zirconia crowns and 87.0 ± 16.0 N for the Digident CAD/CAM zirconia crowns. The difference between the mean fracture strengths of the Lava and Digident crowns was statistically significant (P<.001). Lava CAD/CAM zirconia crowns showed a complete fracture of both the veneering porcelain and the core whereas the Digident CAD/CAM zirconia crowns showed fracture only of the veneering porcelain. The fracture strengths of CAD/CAM zirconia crowns differ depending on the compatibility of the core material and the veneering porcelain.

  5. Fractography of clinically fractured, implant-supported dental computer-aided design and computer-aided manufacturing crowns

    PubMed Central

    Lohbauer, Ulrich; Belli, Renan; Cune, Marco S; Schepke, Ulf

    2017-01-01

    Today, a substantial part of the dental crown production uses computer-aided design and computer-aided manufacturing (CAD/CAM) technology. A recent step in restorative dentistry is the replacement of natural tooth structure with pre-polymerized and machined resin-based methacrylic polymers. Recently, a new CAD/CAM composite was launched for the crown indication in the load-bearing area, but the clinical reality forced the manufacturer to withdraw this specific indication. In parallel, a randomized clinical trial of CAD/CAM composite crowns luted on zirconia implant abutments revealed a high incidence of failure within the first year of service. Fractured crowns of this clinical trial were retrieved and submitted to a fractographic examination. The aim of the case series presented in this article was to identify failure reasons for a new type of CAD/CAM composite crown material (Lava Ultimate; 3M Oral Care, St. Paul, Minnesota, USA) via fractographic examinations and analytical assessment of luting surfaces and water absorption behavior. As a result, the debonding of the composite crowns from the zirconia implant abutments was identified as the central reason for failure. The adhesive interface was found the weakest link. A lack of silica at the zirconia surface certainly has compromised the bonding potential of the adhesive system from the beginning. Additionally, the hydrolytic stress released from swelling of the resin-based crown (water absorption) and transfer to the luting interface further added to the interfacial stress and most probably contributed to a great extend to the debonding failure. PMID:29204275

  6. Fractography of clinically fractured, implant-supported dental computer-aided design and computer-aided manufacturing crowns.

    PubMed

    Lohbauer, Ulrich; Belli, Renan; Cune, Marco S; Schepke, Ulf

    2017-01-01

    Today, a substantial part of the dental crown production uses computer-aided design and computer-aided manufacturing (CAD/CAM) technology. A recent step in restorative dentistry is the replacement of natural tooth structure with pre-polymerized and machined resin-based methacrylic polymers. Recently, a new CAD/CAM composite was launched for the crown indication in the load-bearing area, but the clinical reality forced the manufacturer to withdraw this specific indication. In parallel, a randomized clinical trial of CAD/CAM composite crowns luted on zirconia implant abutments revealed a high incidence of failure within the first year of service. Fractured crowns of this clinical trial were retrieved and submitted to a fractographic examination. The aim of the case series presented in this article was to identify failure reasons for a new type of CAD/CAM composite crown material (Lava Ultimate; 3M Oral Care, St. Paul, Minnesota, USA) via fractographic examinations and analytical assessment of luting surfaces and water absorption behavior. As a result, the debonding of the composite crowns from the zirconia implant abutments was identified as the central reason for failure. The adhesive interface was found the weakest link. A lack of silica at the zirconia surface certainly has compromised the bonding potential of the adhesive system from the beginning. Additionally, the hydrolytic stress released from swelling of the resin-based crown (water absorption) and transfer to the luting interface further added to the interfacial stress and most probably contributed to a great extend to the debonding failure.

  7. Internal fit of three-unit fixed dental prostheses produced by computer-aided design/computer-aided manufacturing and the lost-wax metal casting technique assessed using the triple-scan protocol.

    PubMed

    Dahl, Bjørn E; Dahl, Jon E; Rønold, Hans J

    2018-02-01

    Suboptimal adaptation of fixed dental prostheses (FDPs) can lead to technical and biological complications. It is unclear if the computer-aided design/computer-aided manufacturing (CAD/CAM) technique improves adaptation of FDPs compared with FDPs made using the lost-wax and metal casting technique. Three-unit FDPs were manufactured by CAD/CAM based on digital impression of a typodont model. The FDPs were made from one of five materials: pre-sintered zirconium dioxide; hot isostatic pressed zirconium dioxide; lithium disilicate glass-ceramic; milled cobalt-chromium; and laser-sintered cobalt-chromium. The FDPs made using the lost-wax and metal casting technique were used as reference. The fit of the FDPs was analysed using the triple-scan method. The fit was evaluated for both single abutments and three-unit FDPs. The average cement space varied between 50 μm and 300 μm. Insignificant differences in internal fit were observed between the CAD/CAM-manufactured FDPs, and none of the FPDs had cement spaces that were statistically significantly different from those of the reference FDP. For all FDPs, the cement space at a marginal band 0.5-1.0 mm from the preparation margin was less than 100 μm. The milled cobalt-chromium FDP had the closest fit. The cement space of FDPs produced using the CAD/CAM technique was similar to that of FDPs produced using the conventional lost-wax and metal casting technique. © 2017 Eur J Oral Sci.

  8. COINGRAD; Control Oriented Interactive Graphical Analysis and Design.

    ERIC Educational Resources Information Center

    Volz, Richard A.; And Others

    The computer is currently a vital tool in engineering analysis and design. With the introduction of moderately priced graphics terminals, it will become even more important in the future as rapid graphic interaction between the engineer and the computer becomes more feasible in computer-aided design (CAD). To provide a vehicle for introducing…

  9. Enhancements in medicine by integrating content based image retrieval in computer-aided diagnosis

    NASA Astrophysics Data System (ADS)

    Aggarwal, Preeti; Sardana, H. K.

    2010-02-01

    Computer-aided diagnosis (CAD) has become one of the major research subjects in medical imaging and diagnostic radiology. With cad, radiologists use the computer output as a "second opinion" and make the final decisions. Retrieving images is a useful tool to help radiologist to check medical image and diagnosis. The impact of contentbased access to medical images is frequently reported but existing systems are designed for only a particular context of diagnosis. The challenge in medical informatics is to develop tools for analyzing the content of medical images and to represent them in a way that can be efficiently searched and compared by the physicians. CAD is a concept established by taking into account equally the roles of physicians and computers. To build a successful computer aided diagnostic system, all the relevant technologies, especially retrieval need to be integrated in such a manner that should provide effective and efficient pre-diagnosed cases with proven pathology for the current case at the right time. In this paper, it is suggested that integration of content-based image retrieval (CBIR) in cad can bring enormous results in medicine especially in diagnosis. This approach is also compared with other approaches by highlighting its advantages over those approaches.

  10. CBT Pilot Program Instructional Guide. Basic Drafting Skills Curriculum Delivered through CAD Workstations and Artificial Intelligence Software.

    ERIC Educational Resources Information Center

    Smith, Richard J.; Sauer, Mardelle A.

    This guide is intended to assist teachers in using computer-aided design (CAD) workstations and artificial intelligence software to teach basic drafting skills. The guide outlines a 7-unit shell program that may also be used as a generic authoring system capable of supporting computer-based training (CBT) in other subject areas. The first section…

  11. An Educational Exercise Examining the Role of Model Attributes on the Creation and Alteration of CAD Models

    ERIC Educational Resources Information Center

    Johnson, Michael D.; Diwakaran, Ram Prasad

    2011-01-01

    Computer-aided design (CAD) is a ubiquitous tool that today's students will be expected to use proficiently for numerous engineering purposes. Taking full advantage of the features available in modern CAD programs requires that models are created in a manner that allows others to easily understand how they are organized and alter them in an…

  12. Usability Studies In Virtual And Traditional Computer Aided Design Environments For Spatial Awareness

    DTIC Science & Technology

    2017-08-08

    Usability Studies In Virtual And Traditional Computer Aided Design Environments For Spatial Awareness Dr. Syed Adeel Ahmed, Xavier University of...virtual environment with wand interfaces compared directly with a workstation non-stereoscopic traditional CAD interface with keyboard and mouse. In...navigate through a virtual environment. The wand interface provides a significantly improved means of interaction. This study quantitatively measures the

  13. Marginal and internal discrepancies of zirconia copings: effects of milling system and finish line design.

    PubMed

    Ribeiro, Isabella Lima Arrais; Campos, Fernanda; Sousa, Rafael Santiago; Alves, Maria Luiza Lima; Rodrigues, Dalton Matos; Souza, Rodrigo Othavio Assuncão; Bottino, Marco Antonio

    2015-01-01

    Discrepancies at the abutment/crown interface can affect the longevity of zirconia restorations. The aim was to evaluate the marginal and internal discrepancies (MD and ID) of zirconia copings manufactured by two milling systems with different finish lines. Three aluminum-master-dies (h = 5.5 mm; Ψ =7.5 mm; 6΀), with different finish lines (large chamfer [LC]; tilted chamfer [TC]; rounded shoulder [RS]) were fabricated. Twenty impressions were made from each master die and poured. Sixty zirconia copings were manufactured and divided according to the factors "finish line" and "milling system" (n = 10): CAD LC = Computer-aided design/computer-aided manufacturing (CAD/CAM) + LC; CAD TC = CAD/CAM + TC; CAD RS = CAD/CAM + RS; MAD LC = manually aided design/manually aided manufacturing (MAD/MAM) + LC; MAD TC = MAD/MAM + TC; and MAD RS = MAD/MAM + RS. For MD analysis, each coping was fixed, and the distance between the external edges of the coping and the edge of the cervical preparation was measured (50 points). Using the same copings, the ID of each coping was evaluated, by the replica technique, at 12 points equally distributed among the regions (n = 10): Ray (R), axial (A), and occlusal (Occl). The measurements were performed by optical microscopy (Χ250). The data (μm) were subjected to parametric and non-parametric statistical analyses. For the MAD/MAM system, the "finish line" (P = 0.0001) affected significantly the MD median values (μm): LC = 251.80 a , RS = 68.40 a and TC = 8.10 b (Dunn's test). For the CAD/CAM system, the median MD values (μm) were not affected by the factor "finish line" (P = 0.4037): LC = 0.82 a , RS = 0.52 a , and TC = 0.89 a . For the ID, it was observed interaction between the finish line types and the region (P = 0.0001) and between region and milling system (P = 0.0031) (RM-ANOVA). The CAD/CAM system presented lower MD values, regardless the finish line. However, the MAD/MAM system showed ID values smaller than those of CAD/CAM.

  14. Use of interactive graphics in bridge analysis and design.

    DOT National Transportation Integrated Search

    1983-01-01

    This study evaluated the role of computer-aided design (CAD), including interactive graphics, in engineering design applications, especially in the design activities of the Virginia Department of Highways and Transportation. A review of the hardware ...

  15. Automated a complex computer aided design concept generated using macros programming

    NASA Astrophysics Data System (ADS)

    Rizal Ramly, Mohammad; Asrokin, Azharrudin; Abd Rahman, Safura; Zulkifly, Nurul Ain Md

    2013-12-01

    Changing a complex Computer Aided design profile such as car and aircraft surfaces has always been difficult and challenging. The capability of CAD software such as AutoCAD and CATIA show that a simple configuration of a CAD design can be easily modified without hassle, but it is not the case with complex design configuration. Design changes help users to test and explore various configurations of the design concept before the production of a model. The purpose of this study is to look into macros programming as parametric method of the commercial aircraft design. Macros programming is a method where the configurations of the design are done by recording a script of commands, editing the data value and adding a certain new command line to create an element of parametric design. The steps and the procedure to create a macro programming are discussed, besides looking into some difficulties during the process of creation and advantage of its usage. Generally, the advantages of macros programming as a method of parametric design are; allowing flexibility for design exploration, increasing the usability of the design solution, allowing proper contained by the model while restricting others and real time feedback changes.

  16. Enhancing Fracture and Wear Resistance of Dentures/Overdentures Utilizing Digital Technology: A Case Series Report.

    PubMed

    Afify, Ahmed; Haney, Stephan

    2016-08-01

    Since it was first introduced into the dental world, computer-aided design/computer-aided manufacturing (CAD/CAM) technology has improved dramatically in regards to both data acquisition and fabrication abilities. CAD/CAM is capable of providing well-fitting intra- and extraoral prostheses when sound guidelines are followed. As CAD/CAM technology encompasses both surgical and prosthetic dental applications as well as fixed and removable aspects, it could improve the average quality of dental prostheses compared with the results obtained by conventional manufacturing methods. The purpose of this article is to provide an introduction into the methods in which this technology may be used to enhance the wear and fracture resistance of dentures and overdentures. This article will also showcase two clinical reports in which CAD/CAM technology has been implemented. © 2016 by the American College of Prosthodontists.

  17. Potential clinical impact of advanced imaging and computer-aided diagnosis in chest radiology: importance of radiologist's role and successful observer study.

    PubMed

    Li, Feng

    2015-07-01

    This review paper is based on our research experience in the past 30 years. The importance of radiologists' role is discussed in the development or evaluation of new medical images and of computer-aided detection (CAD) schemes in chest radiology. The four main topics include (1) introducing what diseases can be included in a research database for different imaging techniques or CAD systems and what imaging database can be built by radiologists, (2) understanding how radiologists' subjective judgment can be combined with technical objective features to improve CAD performance, (3) sharing our experience in the design of successful observer performance studies, and (4) finally, discussing whether the new images and CAD systems can improve radiologists' diagnostic ability in chest radiology. In conclusion, advanced imaging techniques and detection/classification of CAD systems have a potential clinical impact on improvement of radiologists' diagnostic ability, for both the detection and the differential diagnosis of various lung diseases, in chest radiology.

  18. Computer aided design environment for the analysis and design of multi-body flexible structures

    NASA Technical Reports Server (NTRS)

    Ramakrishnan, Jayant V.; Singh, Ramen P.

    1989-01-01

    A computer aided design environment consisting of the programs NASTRAN, TREETOPS and MATLAB is presented in this paper. With links for data transfer between these programs, the integrated design of multi-body flexible structures is significantly enhanced. The CAD environment is used to model the Space Shuttle/Pinhole Occulater Facility. Then a controller is designed and evaluated in the nonlinear time history sense. Recent enhancements and ongoing research to add more capabilities are also described.

  19. Improved Foundry Castings Utilizing CAD/CAM (Computer Aided Design/ Computer Aided Manufacture). Volume 1. Overview

    DTIC Science & Technology

    1988-06-30

    casting. 68 Figure 1-9: Line printer representation of roll solidification. 69 Figure I1-1: Test casting model. 76 Figure 11-2: Division of test casting...writing new casting analysis and design routines. The new routines would take advantage of advanced criteria for predicting casting soundness and cast...properties and technical advances in computer hardware and software. 11 2. CONCLUSIONS UPCAST, a comprehensive software package, has been developed for

  20. Creation of a 3-dimensional virtual dental patient for computer-guided surgery and CAD-CAM interim complete removable and fixed dental prostheses: A clinical report.

    PubMed

    Harris, Bryan T; Montero, Daniel; Grant, Gerald T; Morton, Dean; Llop, Daniel R; Lin, Wei-Shao

    2017-02-01

    This clinical report proposes a digital workflow using 2-dimensional (2D) digital photographs, a 3D extraoral facial scan, and cone beam computed tomography (CBCT) volumetric data to create a 3D virtual patient with craniofacial hard tissue, remaining dentition (including surrounding intraoral soft tissue), and the realistic appearance of facial soft tissue at an exaggerated smile under static conditions. The 3D virtual patient was used to assist the virtual diagnostic tooth arrangement process, providing patient with a pleasing preoperative virtual smile design that harmonized with facial features. The 3D virtual patient was also used to gain patient's pretreatment approval (as a communication tool), design a prosthetically driven surgical plan for computer-guided implant surgery, and fabricate the computer-aided design and computer-aided manufacturing (CAD-CAM) interim prostheses. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  1. Computer-aided design of biological circuits using TinkerCell

    PubMed Central

    Bergmann, Frank T; Sauro, Herbert M

    2010-01-01

    Synthetic biology is an engineering discipline that builds on modeling practices from systems biology and wet-lab techniques from genetic engineering. As synthetic biology advances, efficient procedures will be developed that will allow a synthetic biologist to design, analyze and build biological networks. In this idealized pipeline, computer-aided design (CAD) is a necessary component. The role of a CAD application would be to allow efficient transition from a general design to a final product. TinkerCell is a design tool for serving this purpose in synthetic biology. In TinkerCell, users build biological networks using biological parts and modules. The network can be analyzed using one of several functions provided by TinkerCell or custom programs from third-party sources. Since best practices for modeling and constructing synthetic biology networks have not yet been established, TinkerCell is designed as a flexible and extensible application that can adjust itself to changes in the field. PMID:21327060

  2. Industry Supplied CAD Curriculum: Case Study on Passing Certification Exams

    ERIC Educational Resources Information Center

    Webster, Rustin; Dues, Joseph; Ottway, Rudy

    2017-01-01

    Students who successfully pass professional certification exams while in school are often targeted first by industry for internships and entry level positions. Over the last decade, leading industry suppliers of computer-aided design (CAD) software have developed and launched certification exams for many of their product offerings. Some have also…

  3. Preparing Students for Computer Aided Drafting (CAD). A Conceptual Approach.

    ERIC Educational Resources Information Center

    Putnam, A. R.; Duelm, Brian

    This presentation outlines guidelines for developing and implementing an introductory course in computer-aided drafting (CAD) that is geared toward secondary-level students. The first section of the paper, which deals with content identification and selection, includes lists of mechanical drawing and CAD competencies and a list of rationales for…

  4. Prosthetics & Orthotics Manufacturing Initiative (POMI)

    DTIC Science & Technology

    2012-12-21

    could also allow for ‘virtual innovation,’ the testing of very novel socket designs without ever risking a patient’s well-being. In order to inform...that RL so that a computer aided design (CAD) socket can be fabricated for that individual. 3. Test the fit of the CAD socket through...developed a 4 layer braid laminate design that worked for manufacturing purposes but there was no testing of the laminate to determine if all strength

  5. Comparative fracture strength analysis of Lava and Digident CAD/CAM zirconia ceramic crowns

    PubMed Central

    Kwon, Taek-Ka; Pak, Hyun-Soon; Han, Jung-Suk; Lee, Jai-Bong; Kim, Sung-Hun

    2013-01-01

    PURPOSE All-ceramic crowns are subject to fracture during function. To minimize this common clinical complication, zirconium oxide has been used as the framework for all-ceramic crowns. The aim of this study was to compare the fracture strengths of two computer-aided design/computer-aided manufacturing (CAD/CAM) zirconia crown systems: Lava and Digident. MATERIALS AND METHODS Twenty Lava CAD/CAM zirconia crowns and twenty Digident CAD/CAM zirconia crowns were fabricated. A metal die was also duplicated from the original prepared tooth for fracture testing. A universal testing machine was used to determine the fracture strength of the crowns. RESULTS The mean fracture strengths were as follows: 54.9 ± 15.6 N for the Lava CAD/CAM zirconia crowns and 87.0 ± 16.0 N for the Digident CAD/CAM zirconia crowns. The difference between the mean fracture strengths of the Lava and Digident crowns was statistically significant (P<.001). Lava CAD/CAM zirconia crowns showed a complete fracture of both the veneering porcelain and the core whereas the Digident CAD/CAM zirconia crowns showed fracture only of the veneering porcelain. CONCLUSION The fracture strengths of CAD/CAM zirconia crowns differ depending on the compatibility of the core material and the veneering porcelain. PMID:23755332

  6. Information Infrastructures for Integrated Enterprises

    DTIC Science & Technology

    1993-05-01

    PROCESSING demographic CAM realization; ule leveling; studies; prelimi- rapid tooling; con- accounting/admin- nary CAFE and tinuous cost istrative reports...nies might consider franchising some facets of indirect labor, such as selected functions of administration, finance, and human resources. Incorporate as...vices CAFE Corporate Average Fuel Economy CAD Computer-Aided Design 0 CAE Computer-Aided Engineering CAIS Common Ada Programming Support Environment

  7. Virtual Reality-Based Technologies in Dental Medicine: Knowledge, Attitudes and Practice among Students and Practitioners

    ERIC Educational Resources Information Center

    Sabalic, Maja; Schoener, Jason D.

    2017-01-01

    Virtual reality-based technologies have been used in dentistry for almost two decades. Dental simulators, planning software and CAD/CAM (computer-aided design/computer-aided manufacturing) systems have significantly developed over the years and changed both dental education and clinical practice. This study aimed to assess the knowledge, attitudes…

  8. Space Spurred Computer Graphics

    NASA Technical Reports Server (NTRS)

    1983-01-01

    Dicomed Corporation was asked by NASA in the early 1970s to develop processing capabilities for recording images sent from Mars by Viking spacecraft. The company produced a film recorder which increased the intensity levels and the capability for color recording. This development led to a strong technology base resulting in sophisticated computer graphics equipment. Dicomed systems are used to record CAD (computer aided design) and CAM (computer aided manufacturing) equipment, to update maps and produce computer generated animation.

  9. Integration of a CAD System Into an MDO Framework

    NASA Technical Reports Server (NTRS)

    Townsend, J. C.; Samareh, J. A.; Weston, R. P.; Zorumski, W. E.

    1998-01-01

    NASA Langley has developed a heterogeneous distributed computing environment, called the Framework for Inter-disciplinary Design Optimization, or FIDO. Its purpose has been to demonstrate framework technical feasibility and usefulness for optimizing the preliminary design of complex systems and to provide a working environment for testing optimization schemes. Its initial implementation has been for a simplified model of preliminary design of a high-speed civil transport. Upgrades being considered for the FIDO system include a more complete geometry description, required by high-fidelity aerodynamics and structures codes and based on a commercial Computer Aided Design (CAD) system. This report presents the philosophy behind some of the decisions that have shaped the FIDO system and gives a brief case study of the problems and successes encountered in integrating a CAD system into the FEDO framework.

  10. IPAD 2: Advances in Distributed Data Base Management for CAD/CAM

    NASA Technical Reports Server (NTRS)

    Bostic, S. W. (Compiler)

    1984-01-01

    The Integrated Programs for Aerospace-Vehicle Design (IPAD) Project objective is to improve engineering productivity through better use of computer-aided design and manufacturing (CAD/CAM) technology. The focus is on development of technology and associated software for integrated company-wide management of engineering information. The objectives of this conference are as follows: to provide a greater awareness of the critical need by U.S. industry for advancements in distributed CAD/CAM data management capability; to present industry experiences and current and planned research in distributed data base management; and to summarize IPAD data management contributions and their impact on U.S. industry and computer hardware and software vendors.

  11. Genetic Design Automation: engineering fantasy or scientific renewal?

    PubMed Central

    Lux, Matthew W.; Bramlett, Brian W.; Ball, David A.; Peccoud, Jean

    2013-01-01

    Synthetic biology aims to make genetic systems more amenable to engineering, which has naturally led to the development of Computer-Aided Design (CAD) tools. Experimentalists still primarily rely on project-specific ad-hoc workflows instead of domain-specific tools, suggesting that CAD tools are lagging behind the front line of the field. Here, we discuss the scientific hurdles that have limited the productivity gains anticipated from existing tools. We argue that the real value of efforts to develop CAD tools is the formalization of genetic design rules that determine the complex relationships between genotype and phenotype. PMID:22001068

  12. Computer-Aided-Design of the Hydraulic System of Three-Dimensional Cartridge Valve Blocks (Selected Articles)

    DTIC Science & Technology

    1991-03-21

    sectional representation of the spatial figure can be correctly determined. 6 The AutoLisp language system in the AutoCAD software provides the most...softwares are developed on the 32-bit machines and little progress has been reported for the 16-bit machines. Even the AutoCAD is a two-ard-a-half... AutoCAD software as the basis, developed the design package of 3-D cartridge valve blocks on IM PC/AT. To realize the 3-D displaying of cartridge valves

  13. [An experimental research on the fabrication of the fused porcelain to CAD/CAM molar crown].

    PubMed

    Dai, Ning; Zhou, Yongyao; Liao, Wenhe; Yu, Qing; An, Tao; Jiao, Yiqun

    2007-02-01

    This paper introduced the fabrication process of the fused porcelain to molar crown with CAD/CAM technology. Firstly, preparation teeth data was retrieved by the 3D-optical measuring system. Then, we have reconstructed the inner surface designed the outer surface shape with the computer aided design software. Finally, the mini high-speed NC milling machine was used to produce the fused porcelain to CAD/CAM molar crown. The result has proved that the fabrication process is reliable and efficient. The dental restoration quality is steady and precise.

  14. Data engineering systems: Computerized modeling and data bank capabilities for engineering analysis

    NASA Technical Reports Server (NTRS)

    Kopp, H.; Trettau, R.; Zolotar, B.

    1984-01-01

    The Data Engineering System (DES) is a computer-based system that organizes technical data and provides automated mechanisms for storage, retrieval, and engineering analysis. The DES combines the benefits of a structured data base system with automated links to large-scale analysis codes. While the DES provides the user with many of the capabilities of a computer-aided design (CAD) system, the systems are actually quite different in several respects. A typical CAD system emphasizes interactive graphics capabilities and organizes data in a manner that optimizes these graphics. On the other hand, the DES is a computer-aided engineering system intended for the engineer who must operationally understand an existing or planned design or who desires to carry out additional technical analysis based on a particular design. The DES emphasizes data retrieval in a form that not only provides the engineer access to search and display the data but also links the data automatically with the computer analysis codes.

  15. Computer-aided roll pass design in rolling of airfoil shapes

    NASA Technical Reports Server (NTRS)

    Akgerman, N.; Lahoti, G. D.; Altan, T.

    1980-01-01

    This paper describes two computer-aided design (CAD) programs developed for modeling the shape rolling process for airfoil sections. The first program, SHPROL, uses a modular upper-bound method of analysis and predicts the lateral spread, elongation, and roll torque. The second program, ROLPAS, predicts the stresses, roll separating force, the roll torque and the details of metal flow by simulating the rolling process, using the slab method of analysis. ROLPAS is an interactive program; it offers graphic display capabilities and allows the user to interact with the computer via a keyboard, CRT, and a light pen. The accuracy of the computerized models was evaluated by (a) rolling a selected airfoil shape at room temperature from 1018 steel and isothermally at high temperature from Ti-6Al-4V, and (b) comparing the experimental results with computer predictions. The comparisons indicated that the CAD systems, described here, are useful for practical engineering purposes and can be utilized in roll pass design and analysis for airfoil and similar shapes.

  16. Integrating three-dimensional digital technologies for comprehensive implant dentistry.

    PubMed

    Patel, Neal

    2010-06-01

    The increase in the popularity of and the demand for the use of dental implants to replace teeth has encouraged advancement in clinical technology and materials to improve patients' acceptance and clinical outcomes. Recent advances such as three-dimensional dental radiography with cone-beam computed tomography (CBCT), precision dental implant planning software and clinical execution with guided surgery all play a role in the success of implant dentistry. The author illustrates the technique of comprehensive implant dentistry planning through integration of computer-aided design/computer-aided manufacturing (CAD/CAM) and CBCT data. The technique includes clinical treatment with guided surgery, including the creation of a final restoration with a high-strength ceramic (IPS e.max CAD, Ivoclar Vivadent, Amherst, N.Y.). The author also introduces a technique involving CAD/CAM for fabricating custom implant abutments. The release of software integrating CEREC Acquisition Center with Bluecam (Sirona Dental Systems, Charlotte, N.C.) chairside CAD/CAM and Galileos CBCT imaging (Sirona Dental Systems) allows dentists to plan implant placement, perform implant dentistry with increased precision and provide predictable restorative results by using chairside IPS e.max CAD. The precision of clinical treatment provided by the integration of CAD/CAM and CBCT allows dentists to plan for ideal surgical placement and the appropriate thickness of restorative modalities before placing implants.

  17. Experiments to evolve toward a tangible user interface for computer-aided design parts assembly

    NASA Astrophysics Data System (ADS)

    Legardeur, Jeremy; Garreau, Ludovic; Couture, Nadine

    2004-05-01

    In this paper, we present the concepts of the ESKUA (Experimentation of a Kinesics System Usable for Assembly) platform that allows designers to carry out the assembly of mechanical CAD (Computer Aided Design) parts. This platform, based on tangible user interface lead taking into account assembly constraints from the beginning of the design phase and especially during the phase of CAD models manipulation. Our goal is to propose a working environment where the designer is confronted with real assembly constraints which are currently masked by existing CAD software functionalities. Thus, the platform is based on the handling of physical objects, called tangible interactors, which enable having a physical perception of the assembly constraints. In this goal, we have defined a typology of interactors based on concepts proposed in Design For Assembly methods. We present here the results of studies that led to the evolution of this first interactors set. One is concerning an experiment to evaluate the cognitive aspects of the use of interactors. The other is about an analysis of existing mechanical product and fasteners. We will show how these studies lead to the evolution of the interactors based on the functional surfaces use.

  18. Computer-aided analysis and design of the shape rolling process for producing turbine engine airfoils

    NASA Technical Reports Server (NTRS)

    Lahoti, G. D.; Akgerman, N.; Altan, T.

    1978-01-01

    Mild steel (AISI 1018) was selected as model cold-rolling material and Ti-6Al-4V and INCONEL 718 were selected as typical hot-rolling and cold-rolling alloys, respectively. The flow stress and workability of these alloys were characterized and friction factor at the roll/workpiece interface was determined at their respective working conditions by conducting ring tests. Computer-aided mathematical models for predicting metal flow and stresses, and for simulating the shape-rolling process were developed. These models utilize the upper-bound and the slab methods of analysis, and are capable of predicting the lateral spread, roll-separating force, roll torque and local stresses, strains and strain rates. This computer-aided design (CAD) system is also capable of simulating the actual rolling process and thereby designing roll-pass schedule in rolling of an airfoil or similar shape. The predictions from the CAD system were verified with respect to cold rolling of mild steel plates. The system is being applied to cold and hot isothermal rolling of an airfoil shape, and will be verified with respect to laboratory experiments under controlled conditions.

  19. Preparing for High Technology: CAD/CAM Programs. Research & Development Series No. 234.

    ERIC Educational Resources Information Center

    Abram, Robert; And Others

    This guide is one of three developed to provide information and resources to assist in planning and developing postsecondary technican training programs in high technology areas. It is specifically intended for vocational-technical educators and planners in the initial stages of planning a specialized training option in computer-aided design (CAD)…

  20. MCST Research Operations | NREL

    Science.gov Websites

    Readiness. Laboratory Utilization. Custom Research Equipment Design-Build Capabilities. Add short description Concept and Design Design Requirements Assessment Controls and Automation Design-Build Services International (SEMI) S2 standard assessment Computer-Aided Design (CAD)/Piping and Instrumentation Diagram (P

  1. SNL Mechanical Computer Aided Design (MCAD) guide 2007.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moore, Brandon; Pollice, Stephanie L.; Martinez, Jack R.

    2007-12-01

    This document is considered a mechanical design best-practice guide to new and experienced designers alike. The contents consist of topics related to using Computer Aided Design (CAD) software, performing basic analyses, and using configuration management. The details specific to a particular topic have been leveraged against existing Product Realization Standard (PRS) and Technical Business Practice (TBP) requirements while maintaining alignment with sound engineering and design practices. This document is to be considered dynamic in that subsequent updates will be reflected in the main title, and each update will be published on an annual basis.

  2. A Comparison of the Effectiveness between Computer Aided Drafting and the Traditional Drafting Techniques as Methods of Teaching Pictorial and Multiview Drawings.

    ERIC Educational Resources Information Center

    Kashef, Ali E.

    A study was conducted to determine the effectiveness of teaching multiview and pictorial drawing using traditional methods and using computer-aided drafting (CAD). Research used a quasi-experimental design; subjects were 37 full- and part-time undergraduate students in industrial technology or technology education courses. The students were…

  3. Implementing Relational Operations in an Object-Oriented Database

    DTIC Science & Technology

    1992-03-01

    computer aided software engineering (CASE) and computer aided design (CAD) tools. There has been some research done in the area of combining...35 2. Prograph Database Engine .................................................................. 38 III. W HY A N R/O...in most business applications where the bulk of data being stored and manipulated is simply textual or numeric data that can be stored and manipulated

  4. Making Ceramic/Polymer Parts By Extrusion Stereolithography

    NASA Technical Reports Server (NTRS)

    Stuffle, Kevin; Mulligan, A.; Creegan, P.; Boulton, J. M.; Lombardi, J. L.; Calvert, P. D.

    1996-01-01

    Extrusion stereolithography developmental method of computer-controlled manufacturing of objects out of ceramic/polymer composite materials. Computer-aided design/computer-aided manufacturing (CAD/CAM) software used to create image of desired part and translate image into motion commands for combination of mechanisms moving resin dispenser. Extrusion performed in coordination with motion of dispenser so buildup of extruded material takes on size and shape of desired part. Part thermally cured after deposition.

  5. Management of CAD/CAM information: Key to improved manufacturing productivity

    NASA Technical Reports Server (NTRS)

    Fulton, R. E.; Brainin, J.

    1984-01-01

    A key element to improved industry productivity is effective management of CAD/CAM information. To stimulate advancements in this area, a joint NASA/Navy/industry project designated Intergrated Programs for Aerospace-Vehicle Design (IPAD) is underway with the goal of raising aerospace industry productivity through advancement of technology to integrate and manage information involved in the design and manufacturing process. The project complements traditional NASA/DOD research to develop aerospace design technology and the Air Force's Integrated Computer-Aided Manufacturing (ICAM) program to advance CAM technology. IPAD research is guided by an Industry Technical Advisory Board (ITAB) composed of over 100 representatives from aerospace and computer companies.

  6. CAD of control systems: Application of nonlinear programming to a linear quadratic formulation

    NASA Technical Reports Server (NTRS)

    Fleming, P.

    1983-01-01

    The familiar suboptimal regulator design approach is recast as a constrained optimization problem and incorporated in a Computer Aided Design (CAD) package where both design objective and constraints are quadratic cost functions. This formulation permits the separate consideration of, for example, model following errors, sensitivity measures and control energy as objectives to be minimized or limits to be observed. Efficient techniques for computing the interrelated cost functions and their gradients are utilized in conjunction with a nonlinear programming algorithm. The effectiveness of the approach and the degree of insight into the problem which it affords is illustrated in a helicopter regulation design example.

  7. Influence of Thermal Cycling on Flexural Properties and Simulated Wear of Computer-aided Design/Computer-aided Manufacturing Resin Composites.

    PubMed

    Tsujimoto, A; Barkmeier, W W; Takamizawa, T; Latta, M A; Miyazaki, M

    The purpose of this study was to evaluate the influence of thermal cycling on the flexural properties and simulated wear of computer-aided design/computer-aided manufacturing (CAD/CAM) resin composites. The six CAD/CAM resin composites used in this study were 1) Lava Ultimate CAD/CAM Restorative (LU); 2) Paradigm MZ100 (PM); 3) CERASMART (CS); 4) Shofu Block HC (SB); 5) KATANA AVENCIA Block (KA); and 6) VITA ENAMIC (VE). Specimens were divided randomly into two groups, one of which was stored in distilled water for 24 hours, and the other of which was subjected to 10,000 thermal cycles. For each material, 15 specimens from each group were used to determine the flexural strength and modulus according to ISO 6872, and 20 specimens from each group were used to examine wear using a localized wear simulation model. The test materials were subjected to a wear challenge of 400,000 cycles in a Leinfelder-Suzuki device (Alabama machine). The materials were placed in custom-cylinder stainless steel fixtures, and simulated localized wear was generated using a stainless steel ball bearing (r=2.387 mm) antagonist in a water slurry of polymethyl methacrylate beads. Simulated wear was determined using a noncontact profilometer (Proscan 2100) with Proscan and AnSur 3D software. The two-way analysis of variance of flexural properties and simulated wear of CAD/CAM resin composites revealed that material type and thermal cycling had a significant influence (p<0.05), but there was no significant interaction (p>0.05) between the two factors. The flexural properties and maximum depth of wear facets of CAD/CAM resin composite were different (p<0.05) depending on the material, and their values were influenced (p>0.05) by thermal cycling, except in the case of VE. The volume losses in wear facets on LU, PM, and SB after 10,000 thermal cycles were significantly higher (p<0.05) than those after 24 hours of water storage, unlike CS, KA, and VE. The results of this study indicate that the flexural properties and simulated wear of CAD/CAM resin composites are different depending on the material. In addition, the flexural properties and simulated wear of CAD/CAM resin composites are influenced by thermal cycling.

  8. Computer-aided design for metabolic engineering.

    PubMed

    Fernández-Castané, Alfred; Fehér, Tamás; Carbonell, Pablo; Pauthenier, Cyrille; Faulon, Jean-Loup

    2014-12-20

    The development and application of biotechnology-based strategies has had a great socio-economical impact and is likely to play a crucial role in the foundation of more sustainable and efficient industrial processes. Within biotechnology, metabolic engineering aims at the directed improvement of cellular properties, often with the goal of synthesizing a target chemical compound. The use of computer-aided design (CAD) tools, along with the continuously emerging advanced genetic engineering techniques have allowed metabolic engineering to broaden and streamline the process of heterologous compound-production. In this work, we review the CAD tools available for metabolic engineering with an emphasis, on retrosynthesis methodologies. Recent advances in genetic engineering strategies for pathway implementation and optimization are also reviewed as well as a range of bionalytical tools to validate in silico predictions. A case study applying retrosynthesis is presented as an experimental verification of the output from Retropath, the first complete automated computational pipeline applicable to metabolic engineering. Applying this CAD pipeline, together with genetic reassembly and optimization of culture conditions led to improved production of the plant flavonoid pinocembrin. Coupling CAD tools with advanced genetic engineering strategies and bioprocess optimization is crucial for enhanced product yields and will be of great value for the development of non-natural products through sustainable biotechnological processes. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. A comparison of marginal fit between press-fabricated and CAD/CAM lithium disilicate crowns.

    PubMed

    Carlile, Richard S; Owens, Wade H; Greenwood, William J; Guevara, Peter H

    2018-01-01

    The purpose of this study was to compare the marginal fit of press-fabricated lithium disilicate crowns with that of computer-aided design/computer-aided manufacturing (CAD/CAM) lithium disilicate crowns to determine if the fabrication method has an influence on marginal fit. The marginal fit of 25 pressed and 25 CAD/CAM crowns was measured using the replica technique. The sites measured were the mesial, distal, facial, and lingual margins. A microscope at 10× magnification was used to obtain the measurements. Each site was measured 4 times, and intraclass correlation coefficients were used to assess measurement errors. An unpaired t test was used to evaluate the differences between the 2 groups. Mean marginal gap measurements were greater for CAD/CAM crowns than for pressed crowns at all sites. Only the difference in mean gap at the facial margin was statistically significant (P < 0.001). Press-fabricated lithium disilicate crowns provided a better marginal fit than those fabricated by CAD/CAM, but both fabrication methods provided crowns with a clinically acceptable marginal fit.

  10. Custom CAD-CAM healing abutment and impression coping milled from a poly(methyl methacrylate) block and bonded to a titanium insert.

    PubMed

    Proussaefs, Periklis

    2016-11-01

    This article describes a technique in which a custom-made computer-aided design and computer-aided manufacturing (CAD-CAM) healing abutment milled from a poly(methyl methacrylate) (PMMA) block is fabricated and bonded to a titanium metal insert. An impression is made during dental implant surgery, and the CAD-CAM custom-made healing abutment is fabricated before second-stage surgery while appropriate healing time is allowed for the dental implant to osseointegrate. The contours of the healing abutment are based on the contours of a tentatively designed definitive prosthesis. The healing tissue obtains contours that will be compatible with the contours of the definitive prosthesis. After the milling process is complete, a titanium metal insert is bonded to the healing abutment. Placement of the custom-made CAD-CAM healing abutment at second-stage surgery allows the tissue to obtain contours similar to those of the definitive prosthesis. A custom-made CAD-CAM impression coping milled from a PMMA block and with a titanium insert is used for the definitive impression after the soft tissue has healed. This technique allows guided soft tissue healing by using a custom-made CAD-CAM healing abutment and impression coping. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  11. High-Fidelity 3D-Nanoprinting via Focused Electron Beams: Computer-Aided Design (3BID)

    DOE PAGES

    Fowlkes, Jason D.; Winkler, Robert; Lewis, Brett B.; ...

    2018-02-14

    Currently, there are few techniques that allow true 3D-printing on the nanoscale. The most promising candidate to fill this void is focused electron-beam-induced deposition (FEBID), a resist-free, nanofabrication compatible, direct-write method. The basic working principles of a computer-aided design (CAD) program (3BID) enabling 3D-FEBID is presented and simultaneously released for download. The 3BID capability significantly expands the currently limited toolbox for 3D-nanoprinting, providing access to geometries for optoelectronic, plasmonic, and nanomagnetic applications that were previously unattainable due to the lack of a suitable method for synthesis. In conclusion, the CAD approach supplants trial and error toward more precise/accurate FEBID requiredmore » for real applications/device prototyping.« less

  12. Modelling, simulation and computer-aided design (CAD) of gyrotrons for novel applications in the high-power terahertz science and technologies

    NASA Astrophysics Data System (ADS)

    Sabchevski, S.; Idehara, T.; Damyanova, M.; Zhelyazkov, I.; Balabanova, E.; Vasileva, E.

    2018-03-01

    Gyrotrons are the most powerful sources of CW coherent radiation in the sub-THz and THz frequency bands. In recent years, they have demonstrated a remarkable potential for bridging the so-called THz-gap in the electromagnetic spectrum and opened the road to many novel applications of the terahertz waves. Among them are various advanced spectroscopic techniques (e.g., ESR and DNP-NMR), plasma physics and fusion research, materials processing and characterization, imaging and inspection, new medical technologies and biological studies. In this paper, we review briefly the current status of the research in this broad field and present our problem-oriented software packages developed recently for numerical analysis, computer-aided design (CAD) and optimization of gyrotrons.

  13. High-Fidelity 3D-Nanoprinting via Focused Electron Beams: Computer-Aided Design (3BID)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fowlkes, Jason D.; Winkler, Robert; Lewis, Brett B.

    Currently, there are few techniques that allow true 3D-printing on the nanoscale. The most promising candidate to fill this void is focused electron-beam-induced deposition (FEBID), a resist-free, nanofabrication compatible, direct-write method. The basic working principles of a computer-aided design (CAD) program (3BID) enabling 3D-FEBID is presented and simultaneously released for download. The 3BID capability significantly expands the currently limited toolbox for 3D-nanoprinting, providing access to geometries for optoelectronic, plasmonic, and nanomagnetic applications that were previously unattainable due to the lack of a suitable method for synthesis. In conclusion, the CAD approach supplants trial and error toward more precise/accurate FEBID requiredmore » for real applications/device prototyping.« less

  14. A Digital Approach to Improved Overdentures for the Adolescent Oligodontia Patient.

    PubMed

    Cooper, Lyndon F; Culp, Lee; Luedin, Nicole

    2016-05-01

    The use of overdentures for treatment of oligodontia in adolescent patients using conventional techniques has described limitations. The aim of the case report is to demonstrate the use of CAD (Computer Aided Design) CAM (Computer Aided Manufacture) technology to produce an esthetic monolithic polymethylmethacrylate prosthesis that is retentive and stable on insertion. Adolescent oligodontia patients are typically not suitable candidates for dental implant therapy. Overdentures provide interim or definitive restorative advantages. Given the important esthetic, psychological, and social functions of the prosthesis, an important therapeutic goal for the overdenture prosthesis is esthetics. A CAD-CAM approach to overdenture manufacture can provide a highly esthetic, strong, and retentive prosthesis. CAD-CAM manufacture of monolithic acrylic overdentures offer several advantages that include (1) improved planning and clinical communication, (2) high fidelity manufacture, (3) improved flexural strength, impact strength, and porosity, (4) improved prosthesis integrity and durability (due to the monolithic design), (5) CNC control of occlusal contacts, (6) high esthetic potential due to quality of bulk material and iterative design, and (7) archival nature of the digital prosthesis. CAD-CAM manufacture of monolithic overdentures is a viable approach to completing high value esthetic management of the adolescent oligodontia patient. This case report identifies a new way to utilize CAD CAM technology to produce an improved overdenture for the oligodontia patient. It will be of interest to many and underscores the fundamental principles of smile design transfer to the digital environment. (J Esthet Restor Dent, 2016). © 2016 Wiley Periodicals, Inc.

  15. Digital data acquisition for a CAD/CAM-fabricated titanium framework and zirconium oxide restorations for an implant-supported fixed complete dental prosthesis.

    PubMed

    Lin, Wei-Shao; Metz, Michael J; Pollini, Adrien; Ntounis, Athanasios; Morton, Dean

    2014-12-01

    This dental technique report describes a digital workflow with digital data acquisition at the implant level, computer-aided design and computer-aided manufacturing fabricated, tissue-colored, anodized titanium framework, individually luted zirconium oxide restorations, and autopolymerizing injection-molded acrylic resin to fabricate an implant-supported, metal-ceramic-resin fixed complete dental prosthesis in an edentulous mandible. The 1-step computer-aided design and computer-aided manufacturing fabrication of titanium framework and zirconium oxide restorations can provide a cost-effective alternative to the conventional metal-resin fixed complete dental prosthesis. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  16. In Vitro Analysis of the Fracture Resistance of CAD/CAM Denture Base Resins.

    PubMed

    Steinmassl, Otto; Offermanns, Vincent; Stöckl, Wolfgang; Dumfahrt, Herbert; Grunert, Ingrid; Steinmassl, Patricia-Anca

    2018-03-08

    Computer-aided design and computer-aided manufacturing (CAD/CAM) denture base manufacturers claim to produce their resin pucks under high heat and pressure. Therefore, CAD/CAM dentures are assumed to have enhanced mechanical properties and, as a result, are often produced with lower denture base thicknesses than conventional, manually fabricated dentures. The aim of this study was to investigate if commercially available CAD/CAM denture base resins have more favourable mechanical properties than conventionally processed denture base resins. For this purpose, a series of three-point bending tests conforming to ISO specifications were performed on a total of 80 standardised, rectangular CAD/CAM denture base resin specimens from five different manufacturers (AvaDent, Baltic Denture System, Vita VIONIC, Whole You Nexteeth, and Wieland Digital Dentures). A heat-polymerising resin and an autopolymerising resin served as the control groups. The breaking load, fracture toughness, and the elastic modulus were assessed. Additionally, the fracture surface roughness and texture were investigated. Only one CAD/CAM resin showed a significantly increased breaking load. Two CAD/CAM resins had a significantly higher fracture toughness than the control groups, and all CAD/CAM resins had higher elastic moduli than the controls. Our results indicate that CAD/CAM denture base resins do not generally have better mechanical properties than manually processed resins. Therefore, the lower minimum denture base thicknesses should be regarded with some caution.

  17. In Vitro Analysis of the Fracture Resistance of CAD/CAM Denture Base Resins

    PubMed Central

    Stöckl, Wolfgang; Dumfahrt, Herbert; Grunert, Ingrid

    2018-01-01

    Computer-aided design and computer-aided manufacturing (CAD/CAM) denture base manufacturers claim to produce their resin pucks under high heat and pressure. Therefore, CAD/CAM dentures are assumed to have enhanced mechanical properties and, as a result, are often produced with lower denture base thicknesses than conventional, manually fabricated dentures. The aim of this study was to investigate if commercially available CAD/CAM denture base resins have more favourable mechanical properties than conventionally processed denture base resins. For this purpose, a series of three-point bending tests conforming to ISO specifications were performed on a total of 80 standardised, rectangular CAD/CAM denture base resin specimens from five different manufacturers (AvaDent, Baltic Denture System, Vita VIONIC, Whole You Nexteeth, and Wieland Digital Dentures). A heat-polymerising resin and an autopolymerising resin served as the control groups. The breaking load, fracture toughness, and the elastic modulus were assessed. Additionally, the fracture surface roughness and texture were investigated. Only one CAD/CAM resin showed a significantly increased breaking load. Two CAD/CAM resins had a significantly higher fracture toughness than the control groups, and all CAD/CAM resins had higher elastic moduli than the controls. Our results indicate that CAD/CAM denture base resins do not generally have better mechanical properties than manually processed resins. Therefore, the lower minimum denture base thicknesses should be regarded with some caution. PMID:29518022

  18. Computer Aided Drafting Packages for Secondary Education. Edition 1. Apple II and Macintosh. A MicroSIFT Quarterly Report.

    ERIC Educational Resources Information Center

    Pollard, Jim

    This report reviews software packages for Apple Macintosh and Apple II computers available to secondary schools to teach computer-aided drafting (CAD). Products for the report were gathered through reviews of CAD periodicals, computers in education periodicals, advertisements, and teacher recommendations. The first section lists the primary…

  19. Genetic design automation: engineering fantasy or scientific renewal?

    PubMed

    Lux, Matthew W; Bramlett, Brian W; Ball, David A; Peccoud, Jean

    2012-02-01

    The aim of synthetic biology is to make genetic systems more amenable to engineering, which has naturally led to the development of computer-aided design (CAD) tools. Experimentalists still primarily rely on project-specific ad hoc workflows instead of domain-specific tools, which suggests that CAD tools are lagging behind the front line of the field. Here, we discuss the scientific hurdles that have limited the productivity gains anticipated from existing tools. We argue that the real value of efforts to develop CAD tools is the formalization of genetic design rules that determine the complex relationships between genotype and phenotype. Copyright © 2011 Elsevier Ltd. All rights reserved.

  20. [Preliminary evaluation of clinical effect of computer aided design and computer aided manufacture zirconia crown].

    PubMed

    Wang, Yu-guang; Xing, Yan-xi; Sun, Yu-chun; Zhao, Yi-jiao; Lü, Pei-jun; Wang, Yong

    2013-06-01

    To evaluate clinical effects of computer aided design and computer aided manufacturing (CAD/CAM) milled zirconia crown in three aspects: aesthetic, contact wear and fracture. Sixty patients were divided into two groups.In one group, 35 full contour CAD/CAM zirconia crown were made on molars of 30 patients. The manufacturing process of zirconia crown was as follow. First, the three dimensional(3-D) data of working models, antagonist impression and check records were acquired by 3-D laser scanning Dental wings S50. Then full contour zirconia crowns, which had functional occlusal contacts with antagonistic teeth, and appropriate contact with adjacent teeth were designed with Zeno-CAD(V4.2.5.5.12919) software. ZENOSTAR Zr pure zirconia material was milled in digital controlled machine WIELAND 4030 M1.In the end, the zirconia crown were completed with the method of second sintering and polishing. After clinical try-in, the crown was cemented.In the control group, thirty gold alloy full crown were made and cemented on molars of 30 patients. According to the modified U S Public Health Service Criteria(USPHS) evaluation standard, all crowns were evaluated on the same day, at three months, half a year, one year and two years following delivery. There were three aspects we were focusing on in the evaluation: aesthetic, contact wear(restoration and antagonist), and fracture. In all the prosthesis we evaluated during the 24 months, no fracture was found. Contact wear of crowns varies according to different antagonist teeth. The zirconia crowns show privilege in aesthesis, toughness and anti-wearing.However, there is contact wear on antagonistic natural teeth. Thus it is a good choice when full zirconia crowns are indicated on two antagonistic teeth in both jaws.

  1. Computer Aided Detection of Breast Masses in Digital Tomosynthesis

    DTIC Science & Technology

    2008-06-01

    the suspicious CAD location were extracted. For the second set, 256x256 ROIs representing the - 8 - summed slab of 5 slices (5 mm) were extracted...region hotelling observer, digital tomosynthesis, multi-slice CAD algorithms, biopsy 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18...developing computer-aided detection ( CAD ) tools for mammography. Although these tools have shown promise in identifying calcifications, detecting

  2. Computers in manufacturing

    NASA Astrophysics Data System (ADS)

    Hudson, C. A.

    1982-02-01

    CAD/CAM advances and applications for enhancing productivity in industry are explored. Wide-spread use of CAD/CAM devices are projected to occur by the time period 1992-1997, resulting in a higher percentage of technicians in the manufacturing process, while the cost of computers and software will continue to fall and become more widely available. Computer aided design is becoming a commercially viable system for design and geometric modeling, engineering analysis, kinematics, and drafting, and efforts to bridge the gap between CAD and CAM are indicated, with particular attention given to layering, wherein individual monitoring of different parts of the manufacturing process can be effected without crossover of unnecessary information. The potentials and barriers to the use of robotics are described, with the added optimism that displaced workers to date have moved up to jobs of higher skill and interest.

  3. Using an In-House Approach to Computer-Assisted Design and Computer-Aided Manufacturing Reconstruction of the Maxilla.

    PubMed

    Numajiri, Toshiaki; Morita, Daiki; Nakamura, Hiroko; Tsujiko, Shoko; Yamochi, Ryo; Sowa, Yoshihiro; Toyoda, Kenichiro; Tsujikawa, Takahiro; Arai, Akihito; Yasuda, Makoto; Hirano, Shigeru

    2018-06-01

    Computer-assisted design (CAD) and computer-aided manufacturing (CAM) techniques are in widespread use for maxillofacial reconstruction. However, CAD/CAM surgical guides are commercially available only in limited areas. To use this technology in areas where these commercial guides are not available, the authors developed a CAD/CAM technique in which all processes are performed by the surgeon (in-house approach). The authors describe their experience and the characteristics of their in-house CAD/CAM reconstruction of the maxilla. This was a retrospective study of maxillary reconstruction with a free osteocutaneous flap. Free CAD software was used for virtual surgery and to design the cutting guides (maxilla and fibula), which were printed by a 3-dimensional printer. After the model surgery and pre-bending of the titanium plates, the actual reconstructions were performed. The authors compared the clinical information, preoperative plan, and postoperative reconstruction data. The reconstruction was judged as accurate if more than 80% of the reconstructed points were within a deviation of 2 mm. Although on-site adjustment was necessary in particular cases, all 4 reconstructions were judged as accurate. In total, 3 days were needed before the surgery for planning, printing, and pre-bending of plates. The average ischemic time was 134 minutes (flap suturing and bone fixation, 70 minutes; vascular anastomoses, 64 minutes). The mean deviation after reconstruction was 0.44 mm (standard deviation, 0.97). The deviations were 67.8% for 1 mm, 93.8% for 2 mm, and 98.6% for 3 mm. The disadvantages of the regular use of CAD/CAM reconstruction are the intraoperative changes in defect size and local tissue scarring. Good accuracy was obtained for CAD/CAM-guided reconstructions based on an in-house approach. The theoretical advantage of computer simulation contributes to the accuracy. An in-house approach could be an option for maxillary reconstruction. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  4. An application protocol for CAD to CAD transfer of electronic information

    NASA Technical Reports Server (NTRS)

    Azu, Charles C., Jr.

    1993-01-01

    The exchange of Computer Aided Design (CAD) information between dissimilar CAD systems is a problem. This is especially true for transferring electronics CAD information such as multi-chip module (MCM), hybrid microcircuit assembly (HMA), and printed circuit board (PCB) designs. Currently, there exists several neutral data formats for transferring electronics CAD information. These include IGES, EDIF, and DXF formats. All these formats have limitations for use in exchanging electronic data. In an attempt to overcome these limitations, the Navy's MicroCIM program implemented a project to transfer hybrid microcircuit design information between dissimilar CAD systems. The IGES (Initial Graphics Exchange Specification) format is used since it is well established within the CAD industry. The goal of the project is to have a complete transfer of microelectronic CAD information, using IGES, without any data loss. An Application Protocol (AP) is being developed to specify how hybrid microcircuit CAD information will be represented by IGES entity constructs. The AP defines which IGES data items are appropriate for describing HMA geometry, connectivity, and processing as well as HMA material characteristics.

  5. Computer-aided design of biological circuits using TinkerCell.

    PubMed

    Chandran, Deepak; Bergmann, Frank T; Sauro, Herbert M

    2010-01-01

    Synthetic biology is an engineering discipline that builds on modeling practices from systems biology and wet-lab techniques from genetic engineering. As synthetic biology advances, efficient procedures will be developed that will allow a synthetic biologist to design, analyze, and build biological networks. In this idealized pipeline, computer-aided design (CAD) is a necessary component. The role of a CAD application would be to allow efficient transition from a general design to a final product. TinkerCell is a design tool for serving this purpose in synthetic biology. In TinkerCell, users build biological networks using biological parts and modules. The network can be analyzed using one of several functions provided by TinkerCell or custom programs from third-party sources. Since best practices for modeling and constructing synthetic biology networks have not yet been established, TinkerCell is designed as a flexible and extensible application that can adjust itself to changes in the field. © 2010 Landes Bioscience

  6. A Comparison of Marginal Gaps of All-Ceramic Crowns Constructed from Scanned Impressions and Models.

    PubMed

    Tabesh, Raena; Dudley, James

    This study compared the marginal gaps of computer-aided design/computer-aided manufacture (CAD/CAM)-fabricated all-ceramic crowns constructed from scanned impressions and models and with two different occlusal reduction designs. Two typodont mandibular first molars were prepared to receive CAD/CAM-fabricated all-ceramic crowns. Both molars were prepared to ideal crown reduction, the first with anatomical occlusal reduction (AOR) and the second with completely flat occlusal reduction (FOR). Nine polyvinyl siloxane impressions (PVS) were taken, and nine stone replicas fabricated for each preparation. All impressions and stone models were scanned using a laser scanner (Planmeca Planscan, E4D technologies), and 36 lithium disilicate (IPS e.max CAD) crowns were milled. The marginal gap was measured in four locations using a light stereomicroscope. Crowns constructed from preparations with both occlusal reduction designs demonstrated similar marginal gaps (FOR = 97.98; AOR = 89.12; P = .739). However, all crowns constructed from scanned impressions presented significantly larger marginal gaps than the crowns fabricated from scanned models (impressions = 109.26; models = 77.84; P = .002). Scanning stone models produced all-ceramic crowns with significantly smaller marginal gaps than scanning impressions, irrespective of the occlusal reduction design.

  7. Do Computers Improve the Drawing of a Geometrical Figure for 10 Year-Old Children?

    ERIC Educational Resources Information Center

    Martin, Perrine; Velay, Jean-Luc

    2012-01-01

    Nowadays, computer aided design (CAD) is widely used by designers. Would children learn to draw more easily and more efficiently if they were taught with computerised tools? To answer this question, we made an experiment designed to compare two methods for children to do the same drawing: the classical "pen and paper" method and a CAD…

  8. Is a computer-assisted design and computer-assisted manufacturing method for mandibular reconstruction economically viable?

    PubMed

    Tarsitano, Achille; Battaglia, Salvatore; Crimi, Salvatore; Ciocca, Leonardo; Scotti, Roberto; Marchetti, Claudio

    2016-07-01

    The design and manufacture of patient-specific mandibular reconstruction plates, particularly in combination with cutting guides, has created many new opportunities for the planning and implementation of mandibular reconstruction. Although this surgical method is being used more widely and the outcomes appear to be improved, the question of the additional cost has to be discussed. To evaluate the cost generated by the management of this technology, we studied a cohort of patients treated for mandibular neoplasms. The population was divided into two groups of 20 patients each who were undergoing a 'traditional' freehand mandibular reconstruction or a computer-aided design/computer-aided manufacturing (CAD-CAM) mandibular reconstruction. Data concerning operation time, complications, and days of hospitalisation were used to evaluate costs related to the management of these patients. The mean operating time for the CAD-CAM group was 435 min, whereas that for the freehand group was 550.5 min. The total difference in terms of average time gain was 115.5 min. No microvascular complication occurred in the CAD-CAM group; two complications (10%) were observed in patients undergoing freehand reconstructions. The mean overall lengths of hospital stay were 13.8 days for the CAD-CAM group and 17 days for the freehand group. Finally, considering that the institutional cost per minute of theatre time is €30, the money saved as a result of the time gained was €3,450. This cost corresponds approximately to the total price of the CAD-CAM surgery. In conclusion, we believe that CAD-CAM technology for mandibular reconstruction will become a widely used reconstructive method and that its cost will be covered by gains in terms of surgical time, quality of reconstruction, and reduced complications. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  9. Forced orthodontic extrusion and use of CAD/CAM for reconstruction of grossly destructed crown: A multidisciplinary approach

    PubMed Central

    Kumar, Rahul; Patil, Suvarna

    2012-01-01

    The aim of this study is to present a report of a case where forced orthodontic extrusion and computer-aided design and computer-aided manufacturing (CAD/CAM) technique was used for reconstruction of right maxillary central incisor with grossly destructed crown. Aesthetic rehabilitation of a fractured maxillary right central incisor was performed employing a multidisciplinary approach i.e. conventional endodontic treatment followed by orthodontic extrusion and final restoration using CAD-CAM and one piece milled zirconia post and core with full coverage zirconia crown. After the procedure being completed, periapical radiographs taken at 3 month follow up period demonstrated that the post and core remained well adapted to post space and there was a complete healing of periapical lesion. This technique can provide a complete aesthetic rehabilitation of a grossly destructed tooth without hampering the biological width and thus has a better prognosis. PMID:22557823

  10. New paradigms in internal architecture design and freeform fabrication of tissue engineering porous scaffolds.

    PubMed

    Yoo, Dongjin

    2012-07-01

    Advanced additive manufacture (AM) techniques are now being developed to fabricate scaffolds with controlled internal pore architectures in the field of tissue engineering. In general, these techniques use a hybrid method which combines computer-aided design (CAD) with computer-aided manufacturing (CAM) tools to design and fabricate complicated three-dimensional (3D) scaffold models. The mathematical descriptions of micro-architectures along with the macro-structures of the 3D scaffold models are limited by current CAD technologies as well as by the difficulty of transferring the designed digital models to standard formats for fabrication. To overcome these difficulties, we have developed an efficient internal pore architecture design system based on triply periodic minimal surface (TPMS) unit cell libraries and associated computational methods to assemble TPMS unit cells into an entire scaffold model. In addition, we have developed a process planning technique based on TPMS internal architecture pattern of unit cells to generate tool paths for freeform fabrication of tissue engineering porous scaffolds. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  11. Analyzing Automated Instructional Systems: Metaphors from Related Design Professions.

    ERIC Educational Resources Information Center

    Jonassen, David H.; Wilson, Brent G.

    Noting that automation has had an impact on virtually every manufacturing and information operation in the world, including instructional design (ID), this paper suggests three basic metaphors for automating instructional design activities: (1) computer-aided design and manufacturing (CAD/CAM) systems; (2) expert system advisor systems; and (3)…

  12. Concept of operations for the use of connected vehicle data in road weather applications.

    DOT National Transportation Integrated Search

    2006-01-30

    The Computer Aided Dispatch (CAD) computer system went into live operation January 2002. System design involved creating a distributed network, which involved setting up a central main server at the Idaho State Police (ISP) headquarters located in Me...

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, K.L.

    This document has been developed to provide guidance in the interchange of electronic CAD data with Martin Marietta Energy Systems, Inc., Oak Ridge, Tennessee. It is not meant to be as comprehensive as the existing standards and specifications, but to provide a minimum set of practices that will enhance the success of the CAD data exchange. It is now a Department of Energy (DOE) Oak Ridge Field Office requirement that Architect-Engineering (A-E) firms prepare all new drawings using a Computer Aided Design (CAD) system that is compatible with the Facility Manager`s (FM) CAD system. For Oak Ridge facilities, the CADmore » system used for facility design by the FM, Martin Marietta Energy Systems, Inc., is Intregraph. The format for interchange of CAD data for Oak Ridge facilities will be the Intergraph MicroStation/IGDS format.« less

  14. Hands-on work fine-tunes X-band PIN-diode duplexer

    NASA Astrophysics Data System (ADS)

    Schneider, P.

    1985-06-01

    Computer-aided design (CAD) programs for fabricating PIN-diode duplexers are useful in avoiding time-consuming cut-and-try techniques. Nevertheless, to attain minimum insertion loss, only experimentation yields the optimum microstrip circuitry. A PIN-diode duplexer, consisting of two SPST PIN-diode switches and a pair of 3-dB Lange microstrip couplers, designed for an X-band transmit/receive module exemplifies what is possible when computer-derived designs and experimentation are used together. Differences between the measured and computer-generated figures for insertion loss can be attributed to several factors not included in the CAD program - for example, radiation and connector losses. Mechanical tolerances of the microstrip PC board and variations in the SMA connector-to-microstrip transition contribute to the discrepancy.

  15. Integrating hinge axis approximation and the virtual facial simulation of prosthetic outcomes for treatment with CAD-CAM immediate dentures: A clinical report of a patient with microstomia.

    PubMed

    Kuric, Katelyn M; Harris, Bryan T; Morton, Dean; Azevedo, Bruno; Lin, Wei-Shao

    2017-09-29

    This clinical report describes a digital workflow using extraoral digital photographs and volumetric datasets from cone beam computed tomography (CBCT) imaging to create a 3-dimensional (3D), virtual patient with photorealistic appearance. In a patient with microstomia, hinge axis approximation, diagnostic casts simulating postextraction alveolar ridge profile, and facial simulation of prosthetic treatment outcome were completed in a 3D, virtual environment. The approach facilitated the diagnosis, communication, and patient acceptance of the treatment of maxillary and mandibular computer-aided design and computer-aided manufacturing (CAD-CAM) of immediate dentures at increased occlusal vertical dimension. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  16. Computer Aided Drafting Packages for Secondary Education. Edition 2. PC DOS Compatible Programs. A MicroSIFT Quarterly Report.

    ERIC Educational Resources Information Center

    Pollard, Jim

    This report reviews eight IBM-compatible software packages that are available to secondary schools to teach computer-aided drafting (CAD). Software packages to be considered were selected following reviews of CAD periodicals, computers in education periodicals, advertisements, and recommendations of teachers. The packages were then rated by…

  17. Reconstruction of a Severely Atrophied Alveolar Ridge by Computer-Aided Gingival Simulation and 3D-Printed Surgical Guide: A Case Report.

    PubMed

    Song, In-Seok; Lee, Mi-Ran; Ryu, Jae-Jun; Lee, Ui-Lyong

    Dental implants positioned in severely atrophied anterior maxillae require esthetic or functional compromises. This case report describes the rehabilitation of a severely atrophied alveolar ridge with a three-dimensional (3D) computer-aided design/computer-aided manufacture (CAD/CAM) surgical guide. A 50-year-old woman had a severely atrophied anterior maxilla with unfavorably positioned dental implants. Functional and esthetic prosthodontic restoration was difficult to achieve. An anterior segmental osteotomy was planned to reposition the dental implants. A 3D surgical guide was designed for precise relocation of the segment. The surgical guide firmly grasped the impression copings of the dental implants, minimizing surgical errors. Three-dimensional gingival simulation was used preoperatively to estimate the appropriate position of the gingiva. Rigid fixation to the surrounding bone allowed immobilization of the implant-bone segment. Satisfactory esthetic and functional outcomes were attained 6 months after surgery. Finally, a severely atrophied alveolar ridge with unfavorably positioned dental implants was recovered with minimal esthetic and functional deterioration using gingival simulation and a 3D CAD/CAM surgical guide.

  18. Flume Computer-Aided Design (CAD): Integrated CAD for Microflume Components and Systems

    DTIC Science & Technology

    2002-04-01

    31 3.3: Matching the Mix Ratio (Part B...sizes) will be optimized based on the required flow rates and mixing ratios of the different species. The influence of etch depth is investigated on a...Inhibition Study In this network, the target protein is mixed with protease (i.e. enzyme that cleaves the target protein) and the protease inhibitor (the

  19. Rule-Based Design of Plant Expression Vectors Using GenoCAD.

    PubMed

    Coll, Anna; Wilson, Mandy L; Gruden, Kristina; Peccoud, Jean

    2015-01-01

    Plant synthetic biology requires software tools to assist on the design of complex multi-genic expression plasmids. Here a vector design strategy to express genes in plants is formalized and implemented as a grammar in GenoCAD, a Computer-Aided Design software for synthetic biology. It includes a library of plant biological parts organized in structural categories and a set of rules describing how to assemble these parts into large constructs. Rules developed here are organized and divided into three main subsections according to the aim of the final construct: protein localization studies, promoter analysis and protein-protein interaction experiments. The GenoCAD plant grammar guides the user through the design while allowing users to customize vectors according to their needs. Therefore the plant grammar implemented in GenoCAD will help plant biologists take advantage of methods from synthetic biology to design expression vectors supporting their research projects.

  20. Rapid Analysis of Mass Distribution of Radiation Shielding

    NASA Technical Reports Server (NTRS)

    Zapp, Edward

    2007-01-01

    Radiation Shielding Evaluation Toolset (RADSET) is a computer program that rapidly calculates the spatial distribution of mass of an arbitrary structure for use in ray-tracing analysis of the radiation-shielding properties of the structure. RADSET was written to be used in conjunction with unmodified commercial computer-aided design (CAD) software that provides access to data on the structure and generates selected three-dimensional-appearing views of the structure. RADSET obtains raw geometric, material, and mass data on the structure from the CAD software. From these data, RADSET calculates the distribution(s) of the masses of specific materials about any user-specified point(s). The results of these mass-distribution calculations are imported back into the CAD computing environment, wherein the radiation-shielding calculations are performed.

  1. Effect of different adhesive strategies on microtensile bond strength of computer aided design/computer aided manufacturing blocks bonded to dentin.

    PubMed

    Roperto, Renato; Akkus, Anna; Akkus, Ozan; Lang, Lisa; Sousa-Neto, Manoel Damiao; Teich, Sorin; Porto, Thiago Soares

    2016-01-01

    The aim of this study was to determine the microtensile bond strength (μTBS) of ceramic and composite computer aided design-computer aided manufacturing (CAD-CAM) blocks bonded to dentin using different adhesive strategies. In this in vitro study, 30 crowns of sound freshly extracted human molars were sectioned horizontally 3 mm above the cementoenamel junction to produce flat dentin surfaces. Ceramic and composite CAD/CAM blocks, size 14, were sectioned into slices of 3 mm thick. Before bonding, CAD/CAM block surfaces were treated according to the manufacturer's instructions. Groups were created based on the adhesive strategy used: Group 1 (GI) - conventional resin cement + total-etch adhesive system, Group 2 (GII) - conventional resin cement + self-etch adhesive system, and Group 3 (GIII) - self-adhesive resin cement with no adhesive. Bonded specimens were stored in 100% humidity for 24h at 37΀C, and then sectioned with a slow-speed diamond saw to obtain 1 mm × 1 mm × 6 mm microsticks. Microtensile testing was then conducted using a microtensile tester. μTBS values were expressed in MPa and analyzed by one-way ANOVA with post hoc (Tukey) test at the 5% significance level. Mean values and standard deviations of μTBS (MPa) were 17.68 (±2.71) for GI/ceramic; 17.62 (±3.99) for GI/composite; 13.61 (±6.92) for GII/composite; 12.22 (±4.24) for GII/ceramic; 7.47 (±2.29) for GIII/composite; and 6.48 (±3.10) for GIII/ceramic; ANOVA indicated significant differences among the adhesive modality and block interaction (P < 0.05), and no significant differences among blocks only, except between GI and GII/ceramic. Bond strength of GIII was consistently lower (P < 0.05) than GI and GII groups, regardless the block used. Cementation of CAD/CAM restorations, either composite or ceramic, can be significantly affected by different adhesive strategies used.

  2. Computer aided system for parametric design of combination die

    NASA Astrophysics Data System (ADS)

    Naranje, Vishal G.; Hussein, H. M. A.; Kumar, S.

    2017-09-01

    In this paper, a computer aided system for parametric design of combination dies is presented. The system is developed using knowledge based system technique of artificial intelligence. The system is capable to design combination dies for production of sheet metal parts having punching and cupping operations. The system is coded in Visual Basic and interfaced with AutoCAD software. The low cost of the proposed system will help die designers of small and medium scale sheet metal industries for design of combination dies for similar type of products. The proposed system is capable to reduce design time and efforts of die designers for design of combination dies.

  3. Marginal and internal fits of fixed dental prostheses zirconia retainers.

    PubMed

    Beuer, Florian; Aggstaller, Hans; Edelhoff, Daniel; Gernet, Wolfgang; Sorensen, John

    2009-01-01

    CAM (computer-aided manufacturing) and CAD (computer-aided design)/CAM systems facilitate the use of zirconia substructure materials for all-ceramic fixed partial dentures. This in vitro study compared the precision of fit of frameworks milled from semi-sintered zirconia blocks that were designed and machined with two CAD/CAM and one CAM system. Three-unit posterior fixed dental prostheses (FDP) (n=10) were fabricated for standardized dies by: a milling center CAD/CAM system (Etkon), a laboratory CAD/CAM system (Cerec InLab), and a laboratory CAM system (Cercon). After adaptation by a dental technician, the FDP were cemented on definitive dies, embedded and sectioned. The marginal and internal fits were measured under an optical microscope at 50x magnification. A one-way analysis of variance (ANOVA) was used to compare data (alpha=0.05). The mean (S.D.) for the marginal fit and internal fit adaptation were: 29.1 microm (14.0) and 62.7 microm (18.9) for the milling center system, 56.6 microm (19.6) and 73.5 microm (20.6) for the laboratory CAD/CAM system, and 81.4 microm (20.3) and 119.2 microm (37.5) for the laboratory CAM system. One-way ANOVA showed significant differences between systems for marginal fit (P<0.001) and internal fit (P<0.001). All systems showed marginal gaps below 120 microm and were therefore considered clinically acceptable. The CAD/CAM systems were more precise than the CAM system.

  4. Colonic polyps: application value of computer-aided detection in computed tomographic colonography.

    PubMed

    Zhang, Hui-Mao; Guo, Wei; Liu, Gui-Feng; An, Dong-Hong; Gao, Shuo-Hui; Sun, Li-Bo; Yang, Hai-Shan

    2011-02-01

    Colonic polyps are frequently encountered in clinics. Computed tomographic colonography (CTC), as a painless and quick detection, has high values in clinics. In this study, we evaluated the application value of computer-aided detection (CAD) in CTC detection of colonic polyps in the Chinese population. CTC was performed with a GE 64-row multidetector computed tomography (MDCT) scanner. Data of 50 CTC patients (39 patients positive for at least one polyp of ≥ 0.5 cm in size and the other 11 patients negative by endoscopic detection) were retrospectively reviewed first without computer-aided detection (CAD) and then with CAD by four radiologists (two were experienced and another two inexperienced) blinded to colonoscopy findings. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of detected colonic polyps, as well as the areas under the ROC curves (Az value) with and without CAD were calculated. CAD increased the overall sensitivity, specificity, positive predictive value, negative predictive value and accuracy of the colonic polyps detected by experienced and inexperienced readers. The sensitivity in detecting small polyps (5 - 9 mm) with CAD in experienced and inexperienced readers increased from 82% and 44% to 93% and 82%, respectively (P > 0.05 and P < 0.001). With the use of CAD, the overall false positive rate and false negative rate for the detection of polyps by experienced and inexperienced readers decreased in different degrees. Among 13 sessile polyps not detected by CAD, two were ≥ 1.0 cm, eleven were 5 - 9 mm in diameter, and nine were flat-shaped lesions. The application of CAD in combination with CTC can increase the ability to detect colonic polyps, particularly for inexperienced readers. However, CAD is of limited value for the detection of flat polyps.

  5. Black box integration of computer-aided diagnosis into PACS deserves a second chance: results of a usability study concerning bone age assessment.

    PubMed

    Geldermann, Ina; Grouls, Christoph; Kuhl, Christiane; Deserno, Thomas M; Spreckelsen, Cord

    2013-08-01

    Usability aspects of different integration concepts for picture archiving and communication systems (PACS) and computer-aided diagnosis (CAD) were inquired on the example of BoneXpert, a program determining the skeletal age from a left hand's radiograph. CAD-PACS integration was assessed according to its levels: data, function, presentation, and context integration focusing on usability aspects. A user-based study design was selected. Statements of seven experienced radiologists using two alternative types of integration provided by BoneXpert were acquired and analyzed using a mixed-methods approach based on think-aloud records and a questionnaire. In both variants, the CAD module (BoneXpert) was easily integrated in the workflow, found comprehensible and fitting in the conceptual framework of the radiologists. Weak points of the software integration referred to data and context integration. Surprisingly, visualization of intermediate image processing states (presentation integration) was found less important as compared to efficient handling and fast computation. Seamlessly integrating CAD into the PACS without additional work steps or unnecessary interrupts and without visualizing intermediate images may considerably improve software performance and user acceptance with efforts in time.

  6. Integrated geometry and grid generation system for complex configurations

    NASA Technical Reports Server (NTRS)

    Akdag, Vedat; Wulf, Armin

    1992-01-01

    A grid generation system was developed that enables grid generation for complex configurations. The system called ICEM/CFD is described and its role in computational fluid dynamics (CFD) applications is presented. The capabilities of the system include full computer aided design (CAD), grid generation on the actual CAD geometry definition using robust surface projection algorithms, interfacing easily with known CAD packages through common file formats for geometry transfer, grid quality evaluation of the volume grid, coupling boundary condition set-up for block faces with grid topology generation, multi-block grid generation with or without point continuity and block to block interface requirement, and generating grid files directly compatible with known flow solvers. The interactive and integrated approach to the problem of computational grid generation not only substantially reduces manpower time but also increases the flexibility of later grid modifications and enhancements which is required in an environment where CFD is integrated into a product design cycle.

  7. Workflow of CAD / CAM Scoliosis Brace Adjustment in Preparation Using 3D Printing.

    PubMed

    Weiss, Hans-Rudolf; Tournavitis, Nicos; Nan, Xiaofeng; Borysov, Maksym; Paul, Lothar

    2017-01-01

    High correction bracing is the most effective conservative treatment for patients with scoliosis during growth. Still today braces for the treatment of scoliosis are made by casting patients while computer aided design (CAD) and computer aided manufacturing (CAM) is available with all possibilities to standardize pattern specific brace treatment and improve wearing comfort. CAD / CAM brace production mainly relies on carving a polyurethane foam model which is the basis for vacuuming a polyethylene (PE) or polypropylene (PP) brace. Purpose of this short communication is to describe the workflow currently used and to outline future requirements with respect to 3D printing technology. Description of the steps of virtual brace adjustment as available today are content of this paper as well as an outline of the great potential there is for the future 3D printing technology. For 3D printing of scoliosis braces it is necessary to establish easy to use software plug-ins in order to allow adding 3D printing technology to the current workflow of virtual CAD / CAM brace adjustment. Textures and structures can be added to the brace models at certain well defined locations offering the potential of more wearing comfort without losing in-brace correction. Advances have to be made in the field of CAD / CAM software tools with respect to design and generation of individually structured brace models based on currently well established and standardized scoliosis brace libraries.

  8. Accuracy evaluation of dental models manufactured by CAD/CAM milling method and 3D printing method.

    PubMed

    Jeong, Yoo-Geum; Lee, Wan-Sun; Lee, Kyu-Bok

    2018-06-01

    To evaluate the accuracy of a model made using the computer-aided design/computer-aided manufacture (CAD/CAM) milling method and 3D printing method and to confirm its applicability as a work model for dental prosthesis production. First, a natural tooth model (ANA-4, Frasaco, Germany) was scanned using an oral scanner. The obtained scan data were then used as a CAD reference model (CRM), to produce a total of 10 models each, either using the milling method or the 3D printing method. The 20 models were then scanned using a desktop scanner and the CAD test model was formed. The accuracy of the two groups was compared using dedicated software to calculate the root mean square (RMS) value after superimposing CRM and CAD test model (CTM). The RMS value (152±52 µm) of the model manufactured by the milling method was significantly higher than the RMS value (52±9 µm) of the model produced by the 3D printing method. The accuracy of the 3D printing method is superior to that of the milling method, but at present, both methods are limited in their application as a work model for prosthesis manufacture.

  9. Evaluation of marginal/internal fit of chrome-cobalt crowns: Direct laser metal sintering versus computer-aided design and computer-aided manufacturing.

    PubMed

    Gunsoy, S; Ulusoy, M

    2016-01-01

    The purpose of this study was to evaluate the internal and marginal fit of chrome cobalt (Co-Cr) crowns were fabricated with laser sintering, computer-aided design (CAD) and computer-aided manufacturing, and conventional methods. Polyamide master and working models were designed and fabricated. The models were initially designed with a software application for three-dimensional (3D) CAD (Maya, Autodesk Inc.). All models were fabricated models were produced by a 3D printer (EOSINT P380 SLS, EOS). 128 1-unit Co-Cr fixed dental prostheses were fabricated with four different techniques: Conventional lost wax method, milled wax with lost-wax method (MWLW), direct laser metal sintering (DLMS), and milled Co-Cr (MCo-Cr). The cement film thickness of the marginal and internal gaps was measured by an observer using a stereomicroscope after taking digital photos in ×24. Best fit rates according to mean and standard deviations of all measurements was in DLMS both in premolar (65.84) and molar (58.38) models in μm. A significant difference was found DLMS and the rest of fabrication techniques (P < 0.05). No significant difference was found between MCo-CR and MWLW in all fabrication techniques both in premolar and molar models (P > 0.05). DMLS was best fitting fabrication techniques for single crown based on the results.The best fit was found in marginal; the larger gap was found in occlusal.All groups were within the clinically acceptable misfit range.

  10. [The application of computer aided design and computer aided engineering technique in separation of Pygopagus conjoined twins].

    PubMed

    Zhang, Zhi-cheng; Sun, Tian-sheng; Li, Fang; Tang, Guo-lin

    2009-05-19

    To explore the effect of CAD and CAE related technique in separation of Pygopagus Conjoined Twins. CT images of Pygopagus conjoined twins were obtained and reconstructed in three-dimensional by Mimics software. 3D entity model of skin and spine of conjoined twins were made by fast plastic technique and equipment according to 3D data model. The circumference and area of fused and independent dural sac were measured by software of AutoCAD. The entity model is real reflection of skin and spine of Pygopagus. It was used in the procedures of discussion, sham operation, skin flap design and informed consent. In the measure of MRI, the circumference and area of fused dural sac was more than of independent dural sac, that is to say, the defect of dural sac can be repaired by direct suture. The intraoperative finding match with imaging measure results. The application of CAD and CAE in the procedure of preoperative plan have gave big help to successful separation of Pygopagus Conjoined Twins.

  11. Estimation of the risk of failure for an endodontically treated maxillary premolar with MODP preparation and CAD/CAM ceramic restorations.

    PubMed

    Lin, Chun-Li; Chang, Yen-Hsiang; Pa, Che-An

    2009-10-01

    This study evaluated the risk of failure for an endodontically treated premolar with mesio occlusodistal palatal (MODP) preparation and 3 different computer-aided design/computer-aided manufacturing (CAD/CAM) ceramic restoration configurations. Three 3-dimensional finite element (FE) models designed with CAD/CAM ceramic onlay, endocrown, and conventional crown restorations were constructed to perform simulations. The Weibull function was incorporated with FE analysis to calculate the long-term failure probability relative to different load conditions. The results indicated that the stress values on the enamel, dentin, and luting cement for endocrown restoration were the lowest values relative to the other 2 restorations. Weibull analysis revealed that the individual failure probability in the endocrown enamel, dentin, and luting cement obviously diminished more than those for onlay and conventional crown restorations. The overall failure probabilities were 27.5%, 1%, and 1% for onlay, endocrown, and conventional crown restorations, respectively, in normal occlusal condition. This numeric investigation suggests that endocrown and conventional crown restorations for endodontically treated premolars with MODP preparation present similar longevity.

  12. Luting of CAD/CAM ceramic inlays: direct composite versus dual-cure luting cement.

    PubMed

    Kameyama, Atsushi; Bonroy, Kim; Elsen, Caroline; Lührs, Anne-Katrin; Suyama, Yuji; Peumans, Marleen; Van Meerbeek, Bart; De Munck, Jan

    2015-01-01

    The aim of this study was to investigate bonding effectiveness in direct restorations. A two-step self-etch adhesive and a light-cure resin composite was compared with luting with a conventional dual-cure resin cement and a two-step etch and rinse adhesive. Class-I box-type cavities were prepared. Identical ceramic inlays were designed and fabricated with a computer-aided design/computer-aided manufacturing (CAD/CAM) device. The inlays were seated with Clearfil SE Bond/Clearfil AP-X (Kuraray Medical) or ExciTE F DSC/Variolink II (Ivoclar Vivadent), each by two operators (five teeth per group). The inlays were stored in water for one week at 37°C, whereafter micro-tensile bond strength testing was conducted. The micro-tensile bond strength of the direct composite was significantly higher than that from conventional luting, and was independent of the operator (P<0.0001). Pre-testing failures were only observed with the conventional method. High-power light-curing of a direct composite may be a viable alternative to luting lithium disilicate glass-ceramic CAD/CAM restorations.

  13. Foundation and methodologies in computer-aided diagnosis systems for breast cancer detection.

    PubMed

    Jalalian, Afsaneh; Mashohor, Syamsiah; Mahmud, Rozi; Karasfi, Babak; Saripan, M Iqbal B; Ramli, Abdul Rahman B

    2017-01-01

    Breast cancer is the most prevalent cancer that affects women all over the world. Early detection and treatment of breast cancer could decline the mortality rate. Some issues such as technical reasons, which related to imaging quality and human error, increase misdiagnosis of breast cancer by radiologists. Computer-aided detection systems (CADs) are developed to overcome these restrictions and have been studied in many imaging modalities for breast cancer detection in recent years. The CAD systems improve radiologists' performance in finding and discriminating between the normal and abnormal tissues. These procedures are performed only as a double reader but the absolute decisions are still made by the radiologist. In this study, the recent CAD systems for breast cancer detection on different modalities such as mammography, ultrasound, MRI, and biopsy histopathological images are introduced. The foundation of CAD systems generally consist of four stages: Pre-processing, Segmentation, Feature extraction, and Classification. The approaches which applied to design different stages of CAD system are summarised. Advantages and disadvantages of different segmentation, feature extraction and classification techniques are listed. In addition, the impact of imbalanced datasets in classification outcomes and appropriate methods to solve these issues are discussed. As well as, performance evaluation metrics for various stages of breast cancer detection CAD systems are reviewed.

  14. The effect of CO2 and Nd:YAP lasers on CAD/CAM Ceramics: SEM, EDS and thermal studies.

    PubMed

    El Gamal, Ahmed; Fornaini, Carlo; Rocca, Jean Paul; Muhammad, Omid H; Medioni, Etienne; Cucinotta, Annamaria; Brulat-Bouchard, Nathalie

    2016-03-31

    The objective of this study was to investigate the interaction of infrared laser light on Computer Aided Design and Computer Aided Manufacturing (CAD/CAM) ceramic surfaces. Sixty CAD/CAM ceramic discs were prepared and divided into two different groups: lithiumdisilicate ceramic (IPSe.maxCADs) and Zirconia ceramic (IPSe.maxZirCADs). The laser irradiation was performed on graphite and non-graphite surfaces with a Carbon Dioxide laser at 5W and 10W power in continuous mode (CW mode) and with Neodymium Yttrium Aluminum Perovskite (Nd:YAP) laser at 10W. Surface textures and compositions were examined using Scanning Electron Microscopy (SEM), and Energy Dispersive Spectroscopy (EDS). Thermal elevation was measured by thermocouple during laser irradiation. The SEM observation showed a rough surface plus cracks and fissures on CO2 10W samples and melting areas in Nd:YAP samples; moreover, with CO2 5W smooth and shallow surfaces were observed. EDS analysis revealed that laser irradiation does not result in modifications of the chemical composition even if minor changes in the atomic mass percentage of the components were registered. Thermocouple showed several thermal changes during laser irradiation. CO2 and Nd:YAP lasers modify CAD/CAM ceramic surface without chemical composition modifications.

  15. Foundation and methodologies in computer-aided diagnosis systems for breast cancer detection

    PubMed Central

    Jalalian, Afsaneh; Mashohor, Syamsiah; Mahmud, Rozi; Karasfi, Babak; Saripan, M. Iqbal B.; Ramli, Abdul Rahman B.

    2017-01-01

    Breast cancer is the most prevalent cancer that affects women all over the world. Early detection and treatment of breast cancer could decline the mortality rate. Some issues such as technical reasons, which related to imaging quality and human error, increase misdiagnosis of breast cancer by radiologists. Computer-aided detection systems (CADs) are developed to overcome these restrictions and have been studied in many imaging modalities for breast cancer detection in recent years. The CAD systems improve radiologists' performance in finding and discriminating between the normal and abnormal tissues. These procedures are performed only as a double reader but the absolute decisions are still made by the radiologist. In this study, the recent CAD systems for breast cancer detection on different modalities such as mammography, ultrasound, MRI, and biopsy histopathological images are introduced. The foundation of CAD systems generally consist of four stages: Pre-processing, Segmentation, Feature extraction, and Classification. The approaches which applied to design different stages of CAD system are summarised. Advantages and disadvantages of different segmentation, feature extraction and classification techniques are listed. In addition, the impact of imbalanced datasets in classification outcomes and appropriate methods to solve these issues are discussed. As well as, performance evaluation metrics for various stages of breast cancer detection CAD systems are reviewed. PMID:28435432

  16. Space crew radiation exposure analysis system based on a commercial stand-alone CAD system

    NASA Technical Reports Server (NTRS)

    Appleby, Matthew H.; Golightly, Michael J.; Hardy, Alva C.

    1992-01-01

    Major improvements have recently been completed in the approach to spacecraft shielding analysis. A Computer-Aided Design (CAD)-based system has been developed for determining the shielding provided to any point within or external to the spacecraft. Shielding analysis is performed using a commercially available stand-alone CAD system and a customized ray-tracing subroutine contained within a standard engineering modeling software package. This improved shielding analysis technique has been used in several vehicle design projects such as a Mars transfer habitat, pressurized lunar rover, and the redesigned Space Station. Results of these analyses are provided to demonstrate the applicability and versatility of the system.

  17. Towards a behavioral-matching based compilation of synthetic biology functions.

    PubMed

    Basso-Blandin, Adrien; Delaplace, Franck

    2015-09-01

    The field of synthetic biology is looking forward engineering framework for safely designing reliable de-novo biological functions. In this undertaking, Computer-Aided-Design (CAD) environments should play a central role for facilitating the design. Although, CAD environment is widely used to engineer artificial systems the application in synthetic biology is still in its infancy. In this article we address the problem of the design of a high level language which at the core of CAD environment. More specifically the Gubs (Genomic Unified Behavioural Specification) language is a specification language used to describe the observations of the expected behaviour. The compiler appropriately selects components such that the observation of the synthetic biological function resulting to their assembly complies to the programmed behaviour.

  18. Anniversary Paper: History and status of CAD and quantitative image analysis: The role of Medical Physics and AAPM

    PubMed Central

    Giger, Maryellen L.; Chan, Heang-Ping; Boone, John

    2008-01-01

    The roles of physicists in medical imaging have expanded over the years, from the study of imaging systems (sources and detectors) and dose to the assessment of image quality and perception, the development of image processing techniques, and the development of image analysis methods to assist in detection and diagnosis. The latter is a natural extension of medical physicists’ goals in developing imaging techniques to help physicians acquire diagnostic information and improve clinical decisions. Studies indicate that radiologists do not detect all abnormalities on images that are visible on retrospective review, and they do not always correctly characterize abnormalities that are found. Since the 1950s, the potential use of computers had been considered for analysis of radiographic abnormalities. In the mid-1980s, however, medical physicists and radiologists began major research efforts for computer-aided detection or computer-aided diagnosis (CAD), that is, using the computer output as an aid to radiologists—as opposed to a completely automatic computer interpretation—focusing initially on methods for the detection of lesions on chest radiographs and mammograms. Since then, extensive investigations of computerized image analysis for detection or diagnosis of abnormalities in a variety of 2D and 3D medical images have been conducted. The growth of CAD over the past 20 years has been tremendous—from the early days of time-consuming film digitization and CPU-intensive computations on a limited number of cases to its current status in which developed CAD approaches are evaluated rigorously on large clinically relevant databases. CAD research by medical physicists includes many aspects—collecting relevant normal and pathological cases; developing computer algorithms appropriate for the medical interpretation task including those for segmentation, feature extraction, and classifier design; developing methodology for assessing CAD performance; validating the algorithms using appropriate cases to measure performance and robustness; conducting observer studies with which to evaluate radiologists in the diagnostic task without and with the use of the computer aid; and ultimately assessing performance with a clinical trial. Medical physicists also have an important role in quantitative imaging, by validating the quantitative integrity of scanners and developing imaging techniques, and image analysis tools that extract quantitative data in a more accurate and automated fashion. As imaging systems become more complex and the need for better quantitative information from images grows, the future includes the combined research efforts from physicists working in CAD with those working on quantitative imaging systems to readily yield information on morphology, function, molecular structure, and more—from animal imaging research to clinical patient care. A historical review of CAD and a discussion of challenges for the future are presented here, along with the extension to quantitative image analysis. PMID:19175137

  19. Anniversary Paper: History and status of CAD and quantitative image analysis: The role of Medical Physics and AAPM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Giger, Maryellen L.; Chan, Heang-Ping; Boone, John

    2008-12-15

    The roles of physicists in medical imaging have expanded over the years, from the study of imaging systems (sources and detectors) and dose to the assessment of image quality and perception, the development of image processing techniques, and the development of image analysis methods to assist in detection and diagnosis. The latter is a natural extension of medical physicists' goals in developing imaging techniques to help physicians acquire diagnostic information and improve clinical decisions. Studies indicate that radiologists do not detect all abnormalities on images that are visible on retrospective review, and they do not always correctly characterize abnormalities thatmore » are found. Since the 1950s, the potential use of computers had been considered for analysis of radiographic abnormalities. In the mid-1980s, however, medical physicists and radiologists began major research efforts for computer-aided detection or computer-aided diagnosis (CAD), that is, using the computer output as an aid to radiologists--as opposed to a completely automatic computer interpretation--focusing initially on methods for the detection of lesions on chest radiographs and mammograms. Since then, extensive investigations of computerized image analysis for detection or diagnosis of abnormalities in a variety of 2D and 3D medical images have been conducted. The growth of CAD over the past 20 years has been tremendous--from the early days of time-consuming film digitization and CPU-intensive computations on a limited number of cases to its current status in which developed CAD approaches are evaluated rigorously on large clinically relevant databases. CAD research by medical physicists includes many aspects--collecting relevant normal and pathological cases; developing computer algorithms appropriate for the medical interpretation task including those for segmentation, feature extraction, and classifier design; developing methodology for assessing CAD performance; validating the algorithms using appropriate cases to measure performance and robustness; conducting observer studies with which to evaluate radiologists in the diagnostic task without and with the use of the computer aid; and ultimately assessing performance with a clinical trial. Medical physicists also have an important role in quantitative imaging, by validating the quantitative integrity of scanners and developing imaging techniques, and image analysis tools that extract quantitative data in a more accurate and automated fashion. As imaging systems become more complex and the need for better quantitative information from images grows, the future includes the combined research efforts from physicists working in CAD with those working on quantitative imaging systems to readily yield information on morphology, function, molecular structure, and more--from animal imaging research to clinical patient care. A historical review of CAD and a discussion of challenges for the future are presented here, along with the extension to quantitative image analysis.« less

  20. Incorporating Solid Modeling and Team-Based Design into Freshman Engineering Graphics.

    ERIC Educational Resources Information Center

    Buchal, Ralph O.

    2001-01-01

    Describes the integration of these topics through a major team-based design and computer aided design (CAD) modeling project in freshman engineering graphics at the University of Western Ontario. Involves n=250 students working in teams of four to design and document an original Lego toy. Includes 12 references. (Author/YDS)

  1. Design and fabrication of complete dentures using CAD/CAM technology

    PubMed Central

    Han, Weili; Li, Yanfeng; Zhang, Yue; lv, Yuan; Zhang, Ying; Hu, Ping; Liu, Huanyue; Ma, Zheng; Shen, Yi

    2017-01-01

    Abstract The aim of the study was to test the feasibility of using commercially available computer-aided design and computer-aided manufacturing (CAD/CAM) technology including 3Shape Dental System 2013 trial version, WIELAND V2.0.049 and WIELAND ZENOTEC T1 milling machine to design and fabricate complete dentures. The modeling process of full denture available in the trial version of 3Shape Dental System 2013 was used to design virtual complete dentures on the basis of 3-dimensional (3D) digital edentulous models generated from the physical models. The virtual complete dentures designed were exported to CAM software of WIELAND V2.0.049. A WIELAND ZENOTEC T1 milling machine controlled by the CAM software was used to fabricate physical dentitions and baseplates by milling acrylic resin composite plates. The physical dentitions were bonded to the corresponding baseplates to form the maxillary and mandibular complete dentures. Virtual complete dentures were successfully designed using the software through several steps including generation of 3D digital edentulous models, model analysis, arrangement of artificial teeth, trimming relief area, and occlusal adjustment. Physical dentitions and baseplates were successfully fabricated according to the designed virtual complete dentures using milling machine controlled by a CAM software. Bonding physical dentitions to the corresponding baseplates generated the final physical complete dentures. Our study demonstrated that complete dentures could be successfully designed and fabricated by using CAD/CAM. PMID:28072686

  2. Real-time slicing algorithm for Stereolithography (STL) CAD model applied in additive manufacturing industry

    NASA Astrophysics Data System (ADS)

    Adnan, F. A.; Romlay, F. R. M.; Shafiq, M.

    2018-04-01

    Owing to the advent of the industrial revolution 4.0, the need for further evaluating processes applied in the additive manufacturing application particularly the computational process for slicing is non-trivial. This paper evaluates a real-time slicing algorithm for slicing an STL formatted computer-aided design (CAD). A line-plane intersection equation was applied to perform the slicing procedure at any given height. The application of this algorithm has found to provide a better computational time regardless the number of facet in the STL model. The performance of this algorithm is evaluated by comparing the results of the computational time for different geometry.

  3. Computer-Based Technologies in Dentistry: Types and Applications

    PubMed Central

    Albuha Al-Mussawi, Raja’a M.; Farid, Farzaneh

    2016-01-01

    During dental education, dental students learn how to examine patients, make diagnosis, plan treatment and perform dental procedures perfectly and efficiently. However, progresses in computer-based technologies including virtual reality (VR) simulators, augmented reality (AR) and computer aided design/computer aided manufacturing (CAD/CAM) systems have resulted in new modalities for instruction and practice of dentistry. Virtual reality dental simulators enable repeated, objective and assessable practice in various controlled situations. Superimposition of three-dimensional (3D) virtual images on actual images in AR allows surgeons to simultaneously visualize the surgical site and superimpose informative 3D images of invisible regions on the surgical site to serve as a guide. The use of CAD/CAM systems for designing and manufacturing of dental appliances and prostheses has been well established. This article reviews computer-based technologies, their application in dentistry and their potentials and limitations in promoting dental education, training and practice. Practitioners will be able to choose from a broader spectrum of options in their field of practice by becoming familiar with new modalities of training and practice. PMID:28392819

  4. Computer-Based Technologies in Dentistry: Types and Applications.

    PubMed

    Albuha Al-Mussawi, Raja'a M; Farid, Farzaneh

    2016-06-01

    During dental education, dental students learn how to examine patients, make diagnosis, plan treatment and perform dental procedures perfectly and efficiently. However, progresses in computer-based technologies including virtual reality (VR) simulators, augmented reality (AR) and computer aided design/computer aided manufacturing (CAD/CAM) systems have resulted in new modalities for instruction and practice of dentistry. Virtual reality dental simulators enable repeated, objective and assessable practice in various controlled situations. Superimposition of three-dimensional (3D) virtual images on actual images in AR allows surgeons to simultaneously visualize the surgical site and superimpose informative 3D images of invisible regions on the surgical site to serve as a guide. The use of CAD/CAM systems for designing and manufacturing of dental appliances and prostheses has been well established. This article reviews computer-based technologies, their application in dentistry and their potentials and limitations in promoting dental education, training and practice. Practitioners will be able to choose from a broader spectrum of options in their field of practice by becoming familiar with new modalities of training and practice.

  5. Computer-Aided Drafting. Education for Technology Employment.

    ERIC Educational Resources Information Center

    Northern Illinois Univ., De Kalb. Dept. of Technology.

    This computer-aided drafting (CAD) curriculum was developed to provide drafting instructors in Illinois with a useful guide for relating an important new technological advance to the vocational classroom. The competency-based learning activity guides are written to be used with any CAD system being used at the secondary and postsecondary levels.…

  6. An Integrated Unix-based CAD System for the Design and Testing of Custom VLSI Chips

    NASA Technical Reports Server (NTRS)

    Deutsch, L. J.

    1985-01-01

    A computer aided design (CAD) system that is being used at the Jet Propulsion Laboratory for the design of custom and semicustom very large scale integrated (VLSI) chips is described. The system consists of a Digital Equipment Corporation VAX computer with the UNIX operating system and a collection of software tools for the layout, simulation, and verification of microcircuits. Most of these tools were written by the academic community and are, therefore, available to JPL at little or no cost. Some small pieces of software have been written in-house in order to make all the tools interact with each other with a minimal amount of effort on the part of the designer.

  7. Effect of resin coating and occlusal loading on microleakage of Class II computer-aided design/computer-aided manufacturing fabricated ceramic restorations: a confocal microscopic study.

    PubMed

    Kitayama, Shuzo; Nasser, Nasser A; Pilecki, Peter; Wilson, Ron F; Nikaido, Toru; Tagami, Junji; Watson, Timothy F; Foxton, Richard M

    2011-05-01

    To evaluate the effect of resin coating and occlusal loading on microleakage of class II computer-aided design/computer-aided manufacturing (CAD/CAM) ceramic restorations. Molars were prepared for an mesio-occlusal-distal (MOD) inlay and were divided into two groups: non-coated (controls); and resin-coated, in which the cavity was coated with a combination of a dentin bonding system (Clearfil Protect Bond) and a flowable resin composite (Clearfil Majesty Flow). Ceramic inlays were fabricated using the CAD/CAM technique (CEREC 3) and cemented with resin cement (Clearfil Esthetic Cement). After 24 h of water storage, the restored teeth in each group were divided into two subgroups: unloaded or loaded with an axial force of 80 N at a rate of 2.5 cycles/s for 250,000 cycles while stored in water. After immersion in 0.25% Rhodamine B solution, the teeth were sectioned bucco-lingually at the mesial and distal boxes. Tandem scanning confocal microscopy (TSM) was used for evaluation of microleakage. The locations of the measurements were assigned to the cavity walls and floor. Loading did not have a significant effect on microleakage in either the resin-coated or non-coated group. Resin coating significantly reduced microleakage regardless of loading. The cavity floor exhibited greater microleakage compared to the cavity wall. TSM observation also revealed that microleakage at the enamel surface was minimal regardless of resin coating. In contrast, non-coated dentin showed extensive leakage, whereas resin-coated dentin showed decreased leakage. Resin coating with a combination of a dentin-bonding system and a flowable resin composite may be indicated prior to impression-taking when restoring teeth with CAD/CAM ceramic inlays in order to reduce microleakage at the tooth-resin interface.

  8. Fracture strength testing of crowns made of CAD/CAM composite resins.

    PubMed

    Okada, Ryota; Asakura, Masaki; Ando, Akihiro; Kumano, Hirokazu; Ban, Seiji; Kawai, Tatsushi; Takebe, Jun

    2018-03-28

    The purpose of this study was to ascertain whether computer aided design/computer aided manufacturing (CAD/CAM) composite resin crowns have sufficient strength to withstand the bite force of the molar teeth. The null hypothesis was that the fracture strength of CAD/CAM composite resin crowns is lower than the average maximum bite force of the molar tooth. The crowns, which shape is the right maxillary first molar, were fabricated using four CAD/CAM blanks made of composite resins (Block HC: HC, KZR-CAD HR: HR, KZR-CAD HR2: HR2, Avencia Block: AVE) and one CAD/CAM blank made of lithium disilicate glass-ceramic (IPS e.max CAD: IPS), which was used as a control. Fracture strength of fabricated crowns bonded to metal abutment and biaxial flexural strength of the materials were evaluated. The results of fracture strength test and biaxial flexural strength test showed different tendencies. The fracture strength of CAD/CAM composite resin crowns except HC ranged from 3.3kN to 3.9kN, and was similar to that of IPS (3.3kN). In contrast, biaxial flexural strength of CAD/CAM composite resins ranged from 175MPa to 247MPa, and was significantly lower than that of IPS (360MPa). All CAD/CAM composite resin crowns studied presented about 3-4 times higher fracture strength than the average maximum bite force of the molar tooth (700-900N), which result leads to the conclusion that CAD/CAM composite resin crowns would have sufficient strength to withstand the bite force of the molar teeth. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  9. Richard J. French, Ph.D. | NREL

    Science.gov Websites

    J. French, Ph.D. Photo of Richard J. French Rick French Researcher IV-Chemistry Richard.French Laboratory equipment design and construction Computer-aided design (CAD) Education Ph.D., Chemistry, Oregon State University B.S., Chemistry, Wheaton College Professional Experience Research Scientist, National

  10. A Wireless Communications Systems Laboratory Course

    ERIC Educational Resources Information Center

    Guzelgoz, Sabih; Arslan, Huseyin

    2010-01-01

    A novel wireless communications systems laboratory course is introduced. The course teaches students how to design, test, and simulate wireless systems using modern instrumentation and computer-aided design (CAD) software. One of the objectives of the course is to help students understand the theoretical concepts behind wireless communication…

  11. Internal fit of single crowns produced by CAD-CAM and lost-wax metal casting technique assessed by the triple-scan protocol.

    PubMed

    Dahl, Bjørn Einar; Rønold, Hans Jacob; Dahl, Jon E

    2017-03-01

    Whether single crowns produced by computer-aided design and computer-aided manufacturing (CAD-CAM) have an internal fit comparable to crowns made by lost-wax metal casting technique is unknown. The purpose of this in vitro study was to compare the internal fit of single crowns produced with the lost-wax and metal casting technique with that of single crowns produced with the CAD-CAM technique. The internal fit of 5 groups of single crowns produced with the CAD-CAM technique was compared with that of single crowns produced in cobalt-chromium with the conventional lost-wax and metal casting technique. Comparison was performed using the triple-scan protocol; scans of the master model, the crown on the master model, and the intaglio of the crown were superimposed and analyzed with computer software. The 5 groups were milled presintered zirconia, milled hot isostatic pressed zirconia, milled lithium disilicate, milled cobalt-chromium, and laser-sintered cobalt-chromium. The cement space in both the mesiodistal and buccopalatal directions was statistically smaller (P<.05) for crowns made by the conventional lost-wax and metal casting technique compared with that of crowns produced by the CAD-CAM technique. Single crowns made using the conventional lost-wax and metal casting technique have better internal fit than crowns produced using the CAD-CAM technique. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  12. Computer aided design and manufacturing: analysis and development of research issues

    NASA Astrophysics Data System (ADS)

    Taylor, K.; Jadeja, J. C.

    2005-11-01

    The paper focuses on the current issues in the areas of computer aided manufacturing and design. The importance of integrating CAD and CAM is analyzed. The associated issues with the integration and recent advancements in this field have been documented. The development of methods for enhancing productivity is explored. A research experiment was conducted in the laboratories of West Virginia University with an objective to portray effects of various machining parameters on production. Graphical results and their interpretations are supplied to better realize the main purpose of the experimentation.

  13. Design of Complete Dentures by Adopting CAD Developed for Fixed Prostheses.

    PubMed

    Li, Yanfeng; Han, Weili; Cao, Jing; Iv, Yuan; Zhang, Yue; Han, Yishi; Shen, Yi; Ma, Zheng; Liu, Huanyue

    2018-02-01

    The demand for complete dentures is expected to increase worldwide, but complete dentures are mainly designed and fabricated manually involving a broad series of clinical and laboratory procedures. Therefore, the quality of complete dentures largely depends on the skills of the dentist and technician, leading to difficulty in quality control. Computer-aided design and manufacturing (CAD/CAM) has been used to design and fabricate various dental restorations including dental inlays, veneers, crowns, partial crowns, and fixed partial dentures (FPDs). It has been envisioned that the application of CAD/CAM technology could reduce intensive clinical/laboratory work for the fabrication of complete dentures; however, CAD/CAM is seldom used to fabricate complete dentures due to the lack of suitable CAD software to design virtual complete dentures although the CAM techniques are in a much advanced stage. Here we report the successful design of virtual complete dentures using CAD software of 3Shape Dental System 2012, which was developed for designing fixed prostheses instead of complete dentures. Our results demonstrated that complete dentures could be successfully designed by the combination of two modeling processes, single coping and full anatomical FPD, available in the 3Shape Dental System 2012. © 2016 by the American College of Prosthodontists.

  14. Observer training for computer-aided detection of pulmonary nodules in chest radiography.

    PubMed

    De Boo, Diederick W; van Hoorn, François; van Schuppen, Joost; Schijf, Laura; Scheerder, Maeke J; Freling, Nicole J; Mets, Onno; Weber, Michael; Schaefer-Prokop, Cornelia M

    2012-08-01

    To assess whether short-term feedback helps readers to increase their performance using computer-aided detection (CAD) for nodule detection in chest radiography. The 140 CXRs (56 with a solitary CT-proven nodules and 84 negative controls) were divided into four subsets of 35; each were read in a different order by six readers. Lesion presence, location and diagnostic confidence were scored without and with CAD (IQQA-Chest, EDDA Technology) as second reader. Readers received individual feedback after each subset. Sensitivity, specificity and area under the receiver-operating characteristics curve (AUC) were calculated for readings with and without CAD with respect to change over time and impact of CAD. CAD stand-alone sensitivity was 59 % with 1.9 false-positives per image. Mean AUC slightly increased over time with and without CAD (0.78 vs. 0.84 with and 0.76 vs. 0.82 without CAD) but differences did not reach significance. The sensitivity increased (65 % vs. 70 % and 66 % vs. 70 %) and specificity decreased over time (79 % vs. 74 % and 80 % vs. 77 %) but no significant impact of CAD was found. Short-term feedback does not increase the ability of readers to differentiate true- from false-positive candidate lesions and to use CAD more effectively. • Computer-aided detection (CAD) is increasingly used as an adjunct for many radiological techniques. • Short-term feedback does not improve reader performance with CAD in chest radiography. • Differentiation between true- and false-positive CAD for low conspicious possible lesions proves difficult. • CAD can potentially increase reader performance for nodule detection in chest radiography.

  15. [Contribution of computer-aided design for the conception of custom-made implants in Pectus Excavatum surgical treatment. Experience of the Nantes plastic surgery unit].

    PubMed

    Tilliet Le Dentu, H; Lancien, U; Sellal, O; Duteille, F; Perrot, P

    2018-02-01

    Pectus excavatum is the most common congenital chest malformation and is a common reason for consultation in plastic surgery. Our attitude is most often a filling of the depression with a custom-made silicone prosthesis. The objective of this work was to evaluate the interest of computer-aided design (CAD) of implants compared to the conventional plaster molds method. We have collected all the cases of custom-made silicone implants to treat funnel chests in our plastic surgery department. The quality of the results was evaluated by the patient, and in a blind manner by the surgical team using photographs and standardized surveys. The pre-operative delays, the operating time and length of hospital stays, the number of surgical recoveries, and the post-operative surgical outcomes were recorded. Between 1990 and 2016, we designed 29 silicone thoracic implants in our department. Before 2012, implants were made from plaster chest molds (n=13). After this date, implants were designed by CAD (n=16). Patients rated their results as "good" or "excellent" in 77% and 86% of cases respectively in the plaster and CAD groups. The surgical team's ratings for CAD implant reconstructions were better than in the plaster group: 8.17 versus 6.96 (P=0.001). CAD implants were significantly less detectable than the plaster group implants. The operating time was reduced in the CAO group: 60.2 compared to 74.7minutes in the plaster group (P=0.04), as was the length of hospitalization: 3.5 versus 5.3 days (P=0.01). There were no significant differences between the two groups in terms of post-operative complications. The management of pectus excavatum by a custom-made silicone implant is a minimally invasive method that provides good cosmetic results. The design of these implants is facilitated and qualitatively improved by CAD. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  16. Accuracy of virtual surgical planning of orthognathic surgery with aid of CAD/CAM fabricated surgical splint-A novel 3D analyzing algorithm.

    PubMed

    Chin, Shih-Jan; Wilde, Frank; Neuhaus, Michael; Schramm, Alexander; Gellrich, Nils-Claudius; Rana, Majeed

    2017-12-01

    The benefit of computer-assisted planning in orthognathic surgery has been extensively documented over the last decade. This study aims to evaluate the accuracy of a virtual orthognathic surgical plan by a novel three dimensional (3D) analysis method. Ten patients who required orthognathic surgery were included in this study. A virtual surgical plan was achieved by the combination of a 3D skull model acquired from computed tomography (CT) and surface scanning of the upper and lower dental arch respectively and final occlusal position. Osteotomies and movement of maxilla and mandible were simulated by Dolphin Imaging 11.8 Premium ® (Dolphin Imaging and Management Solutions, Chatsworth, CA). The surgical plan was transferred to surgical splints fabricated by means of Computer Aided Design/Computer Aided Manufacturing (CAD/CAM). Differences of three dimensional measurements between the virtual surgical plan and postoperative results were evaluated. The results from all parameters showed that the virtual surgical plans were successfully transferred by the assistance of CAD/CAM fabricated surgical splint. Wilcoxon's signed rank test showed that no statistically significant deviation between surgical plan and post-operational result could be detected. However, deviation of angle U1 axis-HP and distance of A-CP could not fulfill the clinical success criteria. Virtual surgical planning and CAD/CAM fabricated surgical splint are proven to facilitate treatment planning and offer an accurate surgical result in orthognathic surgery. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  17. Computer-aided detection system for chest radiography: reducing report turnaround times of examinations with abnormalities.

    PubMed

    Kao, E-Fong; Liu, Gin-Chung; Lee, Lo-Yeh; Tsai, Huei-Yi; Jaw, Twei-Shiun

    2015-06-01

    The ability to give high priority to examinations with pathological findings could be very useful to radiologists with large work lists who wish to first evaluate the most critical studies. A computer-aided detection (CAD) system for identifying chest examinations with abnormalities has therefore been developed. To evaluate the effectiveness of a CAD system on report turnaround times of chest examinations with abnormalities. The CAD system was designed to automatically mark chest examinations with possible abnormalities in the work list of radiologists interpreting chest examinations. The system evaluation was performed in two phases: two radiologists interpreted the chest examinations without CAD in phase 1 and with CAD in phase 2. The time information recorded by the radiology information system was then used to calculate the turnaround times. All chest examinations were reviewed by two other radiologists and were divided into normal and abnormal groups. The turnaround times for the examinations with pathological findings with and without the CAD system assistance were compared. The sensitivity and specificity of the CAD for chest abnormalities were 0.790 and 0.697, respectively, and use of the CAD system decreased the turnaround time for chest examinations with abnormalities by 44%. The turnaround times required for radiologists to identify chest examinations with abnormalities could be reduced by using the CAD system. This system could be useful for radiologists with large work lists who wish to first evaluate the most critical studies. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  18. Computer Aided Grid Interface: An Interactive CFD Pre-Processor

    NASA Technical Reports Server (NTRS)

    Soni, Bharat K.

    1997-01-01

    NASA maintains an applications oriented computational fluid dynamics (CFD) efforts complementary to and in support of the aerodynamic-propulsion design and test activities. This is especially true at NASA/MSFC where the goal is to advance and optimize present and future liquid-fueled rocket engines. Numerical grid generation plays a significant role in the fluid flow simulations utilizing CFD. An overall goal of the current project was to develop a geometry-grid generation tool that will help engineers, scientists and CFD practitioners to analyze design problems involving complex geometries in a timely fashion. This goal is accomplished by developing the CAGI: Computer Aided Grid Interface system. The CAGI system is developed by integrating CAD/CAM (Computer Aided Design/Computer Aided Manufacturing) geometric system output and/or Initial Graphics Exchange Specification (IGES) files (including all the NASA-IGES entities), geometry manipulations and generations associated with grid constructions, and robust grid generation methodologies. This report describes the development process of the CAGI system.

  19. Computer Aided Grid Interface: An Interactive CFD Pre-Processor

    NASA Technical Reports Server (NTRS)

    Soni, Bharat K.

    1996-01-01

    NASA maintains an applications oriented computational fluid dynamics (CFD) efforts complementary to and in support of the aerodynamic-propulsion design and test activities. This is especially true at NASA/MSFC where the goal is to advance and optimize present and future liquid-fueled rocket engines. Numerical grid generation plays a significant role in the fluid flow simulations utilizing CFD. An overall goal of the current project was to develop a geometry-grid generation tool that will help engineers, scientists and CFD practitioners to analyze design problems involving complex geometries in a timely fashion. This goal is accomplished by developing the Computer Aided Grid Interface system (CAGI). The CAGI system is developed by integrating CAD/CAM (Computer Aided Design/Computer Aided Manufacturing) geometric system output and / or Initial Graphics Exchange Specification (IGES) files (including all the NASA-IGES entities), geometry manipulations and generations associated with grid constructions, and robust grid generation methodologies. This report describes the development process of the CAGI system.

  20. Parametric bicubic spline and CAD tools for complex targets shape modelling in physical optics radar cross section prediction

    NASA Astrophysics Data System (ADS)

    Delogu, A.; Furini, F.

    1991-09-01

    Increasing interest in radar cross section (RCS) reduction is placing new demands on theoretical, computation, and graphic techniques for calculating scattering properties of complex targets. In particular, computer codes capable of predicting the RCS of an entire aircraft at high frequency and of achieving RCS control with modest structural changes, are becoming of paramount importance in stealth design. A computer code, evaluating the RCS of arbitrary shaped metallic objects that are computer aided design (CAD) generated, and its validation with measurements carried out using ALENIA RCS test facilities are presented. The code, based on the physical optics method, is characterized by an efficient integration algorithm with error control, in order to contain the computer time within acceptable limits, and by an accurate parametric representation of the target surface in terms of bicubic splines.

  1. Oral features and computerized rehabilitation of a young patient with CHARGE syndrome using minimally invasive long-term interim CAD-CAM restorations.

    PubMed

    Liebermann, Anja; Rafael, Caroline Freitas; Edelhoff, Daniel; Ramberger, Marc; Schweiger, Josef; Maziero Volpato, Claudia Angela; Saeidi Pour, Reza

    2017-04-01

    Patients with CHARGE syndrome (where CHARGE stands for coloboma of the iris or retina, heart defects or cardiac malformations, atresia/stenosis of the choanae, retardation of growth and development, genital anomalies, and ear abnormalities) present several orofacial anomalies. Their treatment depends on the specific type of manifestation. To perform the complex oral rehabilitation and achieve a conservative, esthetic, and functional exploration of the definitive treatment goal, computer-aided design and computer-aided manufacturing (CAD-CAM) polymers can be used as long-term interim restorations. This article reports the treatment of a young patient with CHARGE syndrome combined with oral alterations. CAD-CAM polymers offer an intermediate treatment with satisfying esthetics and function at low biological cost until bone growth is completed. This period facilitates additional planning for the definitive restoration. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  2. The Use of an Online Learning and Teaching System for Monitoring Computer Aided Design Student Participation and Predicting Student Success

    ERIC Educational Resources Information Center

    Akhtar, S.; Warburton, S.; Xu, W.

    2017-01-01

    In this paper we report on the use of a purpose built Computer Support Collaborative learning environment designed to support lab-based CAD teaching through the monitoring of student participation and identified predictors of success. This was carried out by analysing data from the interactive learning system and correlating student behaviour with…

  3. Intelligent Embedded Instruction for Computer-Aided Design (CAD) systems

    DTIC Science & Technology

    1988-10-01

    difficulties were predicted and six lessons were prepared that were aimed at preventing error pattern formation. The lessons were programmed in AUTOLISP ...and arcs, angles of lines, layering (linetype and color), and block creation and insertion. A program written in AUTOLISP examined the values in the...One site had AutoCAD reference manuals nearby and others had no manuals . * Only one site set a schedule for the users. * The attitudes of managers

  4. Comparative Evaluation of a Four-Implant-Supported Polyetherketoneketone Framework Prosthesis: A Three-Dimensional Finite Element Analysis Based on Cone Beam Computed Tomography and Computer-Aided Design.

    PubMed

    Lee, Ki-Sun; Shin, Sang-Wan; Lee, Sang-Pyo; Kim, Jong-Eun; Kim, Jee-Hwan; Lee, Jeong-Yol

    The purpose of this pilot study was to evaluate and compare polyetherketoneketone (PEKK) with different framework materials for implant-supported prostheses by means of a three-dimensional finite element analysis (3D-FEA) based on cone beam computed tomography (CBCT) and computer-aided design (CAD) data. A geometric model that consisted of four maxillary implants supporting a prosthesis framework was constructed from CBCT and CAD data of a treated patient. Three different materials (zirconia, titanium, and PEKK) were selected, and their material properties were simulated using FEA software in the generated geometric model. In the PEKK framework (ie, low elastic modulus) group, the stress transferred to the implant and simulated adjacent tissue was reduced when compressive stress was dominant, but increased when tensile stress was dominant. This study suggests that the shock-absorbing effects of a resilient implant-supported framework are limited in some areas and that rigid framework material shows a favorable stress distribution and safety of overall components of the prosthesis.

  5. [Overall digitalization: leading innovation of endodontics in big data era].

    PubMed

    Ling, J Q

    2016-04-09

    In big data era, digital technologies bring great challenges and opportunities to modern stomatology. The applications of digital technologies, such as cone-beam CT(CBCT), computer aided design,(CAD)and computer aided manufacture(CAM), 3D printing and digital approaches for education , provide new concepts and patterns to the treatment and study of endodontic diseases. This review provides an overview of the application and prospect of commonly used digital technologies in the development of endodontics.

  6. IPAD: A unique approach to government/industry cooperation for technology development and transfer

    NASA Technical Reports Server (NTRS)

    Fulton, Robert E.; Salley, George C.

    1985-01-01

    A key element to improved industry productivity is effective management of Computer Aided Design / Computer Aided Manufacturing (CAD/CAM) information. To stimulate advancement, a unique joint government/industry project designated Integrated Programs for Aerospace-Vehicle Design (IPAD) was carried out from 1971 to 1984. The goal was to raise aerospace industry productivity through advancement of computer based technology to integrate and manage information involved in the design and manufacturing process. IPAD research was guided by an Industry Technical Advisory Board (ITAB) composed of over 100 representatives from aerospace and computer companies. The project complemented traditional NASA/DOD research to develop aerospace design technology and the Air Force's Integrated Computer Aided Manufacturing (ICAM) program to advance CAM technology. IPAD had unprecedented industry support and involvement and served as a unique approach to government industry cooperation in the development and transfer of advanced technology. The IPAD project background, approach, accomplishments, industry involvement, technology transfer mechanisms and lessons learned are summarized.

  7. Analog Computer-Aided Detection (CAD) information can be more effective than binary marks.

    PubMed

    Cunningham, Corbin A; Drew, Trafton; Wolfe, Jeremy M

    2017-02-01

    In socially important visual search tasks, such as baggage screening and diagnostic radiology, experts miss more targets than is desirable. Computer-aided detection (CAD) programs have been developed specifically to improve performance in these professional search tasks. For example, in breast cancer screening, many CAD systems are capable of detecting approximately 90% of breast cancer, with approximately 0.5 false-positive detections per image. Nevertheless, benefits of CAD in clinical settings tend to be small (Birdwell, 2009) or even absent (Meziane et al., 2011; Philpotts, 2009). The marks made by a CAD system can be "binary," giving the same signal to any location where the signal is above some threshold. Alternatively, a CAD system presents an analog signal that reflects strength of the signal at a location. In the experiments reported, we compare analog and binary CAD presentations using nonexpert observers and artificial stimuli defined by two noisy signals: a visible color signal and an "invisible" signal that informed our simulated CAD system. We found that analog CAD generally yielded better overall performance than binary CAD. The analog benefit is similar at high and low target prevalence. Our data suggest that the form of the CAD signal can directly influence performance. Analog CAD may allow the computer to be more helpful to the searcher.

  8. TGeoCad: an Interface between ROOT and CAD Systems

    NASA Astrophysics Data System (ADS)

    Luzzi, C.; Carminati, F.

    2014-06-01

    In the simulation of High Energy Physics experiment a very high precision in the description of the detector geometry is essential to achieve the required performances. The physicists in charge of Monte Carlo Simulation of the detector need to collaborate efficiently with the engineers working at the mechanical design of the detector. Often, this collaboration is made hard by the usage of different and incompatible software. ROOT is an object-oriented C++ framework used by physicists for storing, analyzing and simulating data produced by the high-energy physics experiments while CAD (Computer-Aided Design) software is used for mechanical design in the engineering field. The necessity to improve the level of communication between physicists and engineers led to the implementation of an interface between the ROOT geometrical modeler used by the virtual Monte Carlo simulation software and the CAD systems. In this paper we describe the design and implementation of the TGeoCad Interface that has been developed to enable the use of ROOT geometrical models in several CAD systems. To achieve this goal, the ROOT geometry description is converted into STEP file format (ISO 10303), which can be imported and used by many CAD systems.

  9. Efficient Computational Prototyping of Mixed Technology Microfluidic Components and Systems

    DTIC Science & Technology

    2002-08-01

    AFRL-IF-RS-TR-2002-190 Final Technical Report August 2002 EFFICIENT COMPUTATIONAL PROTOTYPING OF MIXED TECHNOLOGY MICROFLUIDIC...SUBTITLE EFFICIENT COMPUTATIONAL PROTOTYPING OF MIXED TECHNOLOGY MICROFLUIDIC COMPONENTS AND SYSTEMS 6. AUTHOR(S) Narayan R. Aluru, Jacob White...Aided Design (CAD) tools for microfluidic components and systems were developed in this effort. Innovative numerical methods and algorithms for mixed

  10. The effect of CO2 and Nd:YAP lasers on CAD/CAM Ceramics: SEM, EDS and thermal studies

    PubMed Central

    Fornaini, Carlo; Rocca, Jean Paul; Muhammad, Omid H; Medioni, Etienne; Cucinotta, Annamaria; Brulat-Bouchard, Nathalie

    2016-01-01

    Background and aims: The objective of this study was to investigate the interaction of infrared laser light on Computer Aided Design and Computer Aided Manufacturing (CAD/CAM) ceramic surfaces. Material and Methods: Sixty CAD/CAM ceramic discs were prepared and divided into two different groups: lithiumdisilicate ceramic (IPSe.maxCADs) and Zirconia ceramic (IPSe.maxZirCADs). The laser irradiation was performed on graphite and non-graphite surfaces with a Carbon Dioxide laser at 5W and 10W power in continuous mode (CW mode) and with Neodymium Yttrium Aluminum Perovskite (Nd:YAP) laser at 10W. Surface textures and compositions were examined using Scanning Electron Microscopy (SEM), and Energy Dispersive Spectroscopy (EDS). Thermal elevation was measured by thermocouple during laser irradiation. Results: The SEM observation showed a rough surface plus cracks and fissures on CO2 10W samples and melting areas in Nd:YAP samples; moreover, with CO2 5W smooth and shallow surfaces were observed. EDS analysis revealed that laser irradiation does not result in modifications of the chemical composition even if minor changes in the atomic mass percentage of the components were registered. Thermocouple showed several thermal changes during laser irradiation. Conclusion: CO2 and Nd:YAP lasers modify CAD/CAM ceramic surface without chemical composition modifications. PMID:27141152

  11. Web-based computer-aided-diagnosis (CAD) system for bone age assessment (BAA) of children

    NASA Astrophysics Data System (ADS)

    Zhang, Aifeng; Uyeda, Joshua; Tsao, Sinchai; Ma, Kevin; Vachon, Linda A.; Liu, Brent J.; Huang, H. K.

    2008-03-01

    Bone age assessment (BAA) of children is a clinical procedure frequently performed in pediatric radiology to evaluate the stage of skeletal maturation based on a left hand and wrist radiograph. The most commonly used standard: Greulich and Pyle (G&P) Hand Atlas was developed 50 years ago and exclusively based on Caucasian population. Moreover, inter- & intra-observer discrepancies using this method create a need of an objective and automatic BAA method. A digital hand atlas (DHA) has been collected with 1,400 hand images of normal children from Asian, African American, Caucasian and Hispanic descends. Based on DHA, a fully automatic, objective computer-aided-diagnosis (CAD) method was developed and it was adapted to specific population. To bring DHA and CAD method to the clinical environment as a useful tool in assisting radiologist to achieve higher accuracy in BAA, a web-based system with direct connection to a clinical site is designed as a novel clinical implementation approach for online and real time BAA. The core of the system, a CAD server receives the image from clinical site, processes it by the CAD method and finally, generates report. A web service publishes the results and radiologists at the clinical site can review it online within minutes. This prototype can be easily extended to multiple clinical sites and will provide the foundation for broader use of the CAD system for BAA.

  12. Computational System For Rapid CFD Analysis In Engineering

    NASA Technical Reports Server (NTRS)

    Barson, Steven L.; Ascoli, Edward P.; Decroix, Michelle E.; Sindir, Munir M.

    1995-01-01

    Computational system comprising modular hardware and software sub-systems developed to accelerate and facilitate use of techniques of computational fluid dynamics (CFD) in engineering environment. Addresses integration of all aspects of CFD analysis process, including definition of hardware surfaces, generation of computational grids, CFD flow solution, and postprocessing. Incorporates interfaces for integration of all hardware and software tools needed to perform complete CFD analysis. Includes tools for efficient definition of flow geometry, generation of computational grids, computation of flows on grids, and postprocessing of flow data. System accepts geometric input from any of three basic sources: computer-aided design (CAD), computer-aided engineering (CAE), or definition by user.

  13. Learning Reverse Engineering and Simulation with Design Visualization

    NASA Technical Reports Server (NTRS)

    Hemsworth, Paul J.

    2018-01-01

    The Design Visualization (DV) group supports work at the Kennedy Space Center by utilizing metrology data with Computer-Aided Design (CAD) models and simulations to provide accurate visual representations that aid in decision-making. The capability to measure and simulate objects in real time helps to predict and avoid potential problems before they become expensive in addition to facilitating the planning of operations. I had the opportunity to work on existing and new models and simulations in support of DV and NASA’s Exploration Ground Systems (EGS).

  14. Do CAD/CAM dentures really release less monomer than conventional dentures?

    PubMed

    Steinmassl, Patricia-Anca; Wiedemair, Verena; Huck, Christian; Klaunzer, Florian; Steinmassl, Otto; Grunert, Ingrid; Dumfahrt, Herbert

    2017-06-01

    Computer-aided design (CAD)/computer-aided manufacturing (CAM) dentures are assumed to have more favourable material properties than conventionally fabricated dentures, among them a lower methacrylate monomer release. The aim of this study was to test this hypothesis. CAD/CAM dentures were generated from ten different master casts by using four different CAD/CAM systems. Conventional, heat-polymerised dentures served as control group. Denture weight and volume were measured; the density was calculated, and the denture surface area was assessed digitally. The monomer release after 7 days of water storage was measured by high-performance liquid chromatography. Whole You Nexteeth and Wieland Digital Dentures had significantly lower mean volume and weight than conventional dentures. Baltic Denture System and Whole You Nexteeth had a significantly increased density. Baltic Denture System had a significantly smaller surface area. None of the CAD/CAM dentures released significantly less monomer than the control group. All tested dentures released very low amounts of methacrylate monomer, but not significantly less than conventional dentures. A statistically significant difference might nevertheless exist in comparison to other, less recommendable denture base materials, such as the frequently used autopolymerising resins. CAD/CAM denture fabrication has numerous advantages. It enables the fabrication of dentures with lower resin volume and lower denture weight. Both could increase the patient comfort. Dentures with higher density might exhibit more favourable mechanical properties. The hypothesis that CAD/CAM dentures release less monomer than conventional dentures could, however, not be verified.

  15. Computer-aided design of customized foot orthoses: reproducibility and effect of method used to obtain foot shape.

    PubMed

    Telfer, Scott; Gibson, Kellie S; Hennessy, Kym; Steultjens, Martijn P; Woodburn, Jim

    2012-05-01

    To determine, for a number of techniques used to obtain foot shape based around plaster casting, foam box impressions, and 3-dimensional scanning, (1) the effect the technique has on the overall reproducibility of custom foot orthoses (FOs) in terms of inter- and intracaster reliability and (2) the reproducibility of FO design by using computer-aided design (CAD) software in terms of inter- and intra-CAD operator reliability for all these techniques. Cross-sectional study. University laboratory. Convenience sample of individuals (N=22) with noncavus foot types. Not applicable. Parameters of the FO design (length, width at forefoot, width at rearfoot, and peak medial arch height), the forefoot to rearfoot angle of the foot shape, and overall volume match between device designs. For intra- and intercaster reliability of the different methods of obtaining the foot shape, all methods fell below the reproducibility quality threshold for the medial arch height of the device, and volume matching was <80% for all methods. The more experienced CAD operator was able to achieve excellent reliability (intraclass correlation coefficients >0.75) for all variables with the exception of forefoot to rearfoot angle, with overall volume matches of >87% of the devices. None of the techniques for obtaining foot shape met all the criteria for excellent reproducibility, with the peak arch height being particularly variable. Additional variability is added at the CAD stage of the FO design process, although with adequate operator experience good to excellent reproducibility may be achieved at this stage. Taking only basic linear or angular measurement parameters from the device may fail to fully capture the variability in FO design. Copyright © 2012 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  16. Computer-aided design/computer-aided manufacturing skull base drill.

    PubMed

    Couldwell, William T; MacDonald, Joel D; Thomas, Charles L; Hansen, Bradley C; Lapalikar, Aniruddha; Thakkar, Bharat; Balaji, Alagar K

    2017-05-01

    The authors have developed a simple device for computer-aided design/computer-aided manufacturing (CAD-CAM) that uses an image-guided system to define a cutting tool path that is shared with a surgical machining system for drilling bone. Information from 2D images (obtained via CT and MRI) is transmitted to a processor that produces a 3D image. The processor generates code defining an optimized cutting tool path, which is sent to a surgical machining system that can drill the desired portion of bone. This tool has applications for bone removal in both cranial and spine neurosurgical approaches. Such applications have the potential to reduce surgical time and associated complications such as infection or blood loss. The device enables rapid removal of bone within 1 mm of vital structures. The validity of such a machining tool is exemplified in the rapid (< 3 minutes machining time) and accurate removal of bone for transtemporal (for example, translabyrinthine) approaches.

  17. Application of evolutionary computation in ECAD problems

    NASA Astrophysics Data System (ADS)

    Lee, Dae-Hyun; Hwang, Seung H.

    1998-10-01

    Design of modern electronic system is a complicated task which demands the use of computer- aided design (CAD) tools. Since a lot of problems in ECAD are combinatorial optimization problems, evolutionary computations such as genetic algorithms and evolutionary programming have been widely employed to solve those problems. We have applied evolutionary computation techniques to solve ECAD problems such as technology mapping, microcode-bit optimization, data path ordering and peak power estimation, where their benefits are well observed. This paper presents experiences and discusses issues in those applications.

  18. Advanced computer-aided design for bone tissue-engineering scaffolds.

    PubMed

    Ramin, E; Harris, R A

    2009-04-01

    The design of scaffolds with an intricate and controlled internal structure represents a challenge for tissue engineering. Several scaffold-manufacturing techniques allow the creation of complex architectures but with little or no control over the main features of the channel network such as the size, shape, and interconnectivity of each individual channel, resulting in intricate but random structures. The combined use of computer-aided design (CAD) systems and layer-manufacturing techniques allows a high degree of control over these parameters with few limitations in terms of achievable complexity. However, the design of complex and intricate networks of channels required in CAD is extremely time-consuming since manually modelling hundreds of different geometrical elements, all with different parameters, may require several days to design individual scaffold structures. An automated design methodology is proposed by this research to overcome these limitations. This approach involves the investigation of novel software algorithms, which are able to interact with a conventional CAD program and permit the automated design of several geometrical elements, each with a different size and shape. In this work, the variability of the parameters required to define each geometry has been set as random, but any other distribution could have been adopted. This methodology has been used to design five cubic scaffolds with interconnected pore channels that range from 200 to 800 microm in diameter, each with an increased complexity of the internal geometrical arrangement. A clinical case study, consisting of an integration of one of these geometries with a craniofacial implant, is then presented.

  19. The design and integration of retinal CAD-SR to diabetes patient ePR system

    NASA Astrophysics Data System (ADS)

    Wu, Huiqun; Wei, Yufang; Liu, Brent J.; Shang, Yujuan; Shi, Lili; Jiang, Kui; Dong, Jiancheng

    2017-03-01

    Diabetic retinopathy (DR) is one of the serious complications of diabetes that could lead to blindness. Digital fundus camera is often used to detect retinal changes but the diagnosis relies too much on ophthalmologist's experience. Based on our previously developed algorithms for quantifying retinal vessels and lesions, we developed a computer aided detection-structured report (CAD-SR) template and implemented it into picture archiving and communication system (PACS). Furthermore, we mapped our CAD-SR into HL7 CDA to integrate CAD findings into diabetes patient electronic patient record (ePR) system. Such integration could provide more quantitative features from fundus image into ePR system, which is valuable for further data mining researches.

  20. Computer-aided diagnosis (CAD) for colonoscopy

    NASA Astrophysics Data System (ADS)

    Gu, Jia; Poirson, Allen

    2007-03-01

    Colorectal cancer is the second leading cause of cancer deaths, and ranks third for new cancer cases and cancer mortality for both men and women. However, its death rate can be dramatically reduced by appropriate treatment when early detection is available. The purpose of colonoscopy is to identify and assess the severity of lesions, which may be flat or protruding. Due to the subjective nature of the examination, colonoscopic proficiency is highly variable and dependent upon the colonoscopist's knowledge and experience. An automated image processing system providing an objective, rapid, and inexpensive analysis of video from a standard colonoscope could provide a valuable tool for screening and diagnosis. In this paper, we present the design, functionality and preliminary results of its Computer-Aided-Diagnosis (CAD) system for colonoscopy - ColonoCAD TM. ColonoCAD is a complex multi-sensor, multi-data and multi-algorithm image processing system, incorporating data management and visualization, video quality assessment and enhancement, calibration, multiple view based reconstruction, feature extraction and classification. As this is a new field in medical image processing, our hope is that this paper will provide the framework to encourage and facilitate collaboration and discussion between industry, academia, and medical practitioners.

  1. Effect of the Crystallization Process on the Marginal and Internal Gaps of Lithium Disilicate CAD/CAM Crowns.

    PubMed

    Kim, Jae-Hong; Oh, Seunghan; Uhm, Soo-Hyuk

    2016-01-01

    The aim of this study is to quantify the effect of the crystallization process on lithium disilicate ceramic crowns fabricated using a computer-aided design/computer-aided manufacturing (CAD/CAM) system and to determine whether the effect of crystallization is clinically acceptable by comparing values of fit before and after the crystallization process. The mandibular right first molar was selected as the abutment for the experiments. Fifteen working models were prepared. Lithium disilicate crowns appropriate for each abutment were prepared using a commercial CAD/CAM system. Gaps in the marginal area and 4 internal areas of each crown were measured twice-before and after crystallization-using the silicone replica technique. The mean values of fit before and after crystallization were analyzed using a paired t-test to examine whether the conversion that occurred during crystallization affected marginal and internal gaps (α = 0.05). Gaps increased in the marginal area and decreased in the internal areas after crystallization. There were statistically significant differences in all of the investigated areas (P < 0.05). None of the values for marginal and internal fit of lithium disilicate CAD/CAM crowns after crystallization exceeded 120 μm, which is the clinically acceptable threshold.

  2. Stock Versus CAD/CAM Customized Zirconia Implant Abutments – Clinical and Patient‐Based Outcomes in a Randomized Controlled Clinical Trial

    PubMed Central

    Meijer, Henny J.A.; Kerdijk, Wouter; Raghoebar, Gerry M.; Cune, Marco

    2016-01-01

    Abstract Background Single‐tooth replacement often requires a prefabricated dental implant and a customized crown. The benefits of individualization of the abutment remain unclear. Purpose This randomized controlled clinical trial aims to study potential benefits of individualization of zirconia implant abutments with respect to preservation of marginal bone level and several clinical and patient‐based outcome measures. Material and Methods Fifty participants with a missing premolar were included and randomly assigned to standard (ZirDesign, DentsplySirona Implants, Mölndal, Sweden) or computer aided design/computer aided manufacturing (CAD/CAM) customized (Atlantis, DentsplySirona Implants, Mölndal, Sweden) zirconia abutment therapy. Peri‐implant bone level (primary outcome), Plaque‐index, calculus formation, bleeding on probing, gingiva index, probing pocket depth, recession, appearance of soft tissues and patients' contentment were assessed shortly after placement and one year later. Results No implants were lost and no complications related to the abutments were observed. Statistically significant differences between stock and CAD/CAM customized zirconia abutments could not be demonstrated for any of the operationalized variables. Conclusion The use of a CAD/CAM customized zirconia abutment in single tooth replacement of a premolar is not associated with an improvement in clinical performance or patients' contentment when compared to the use of a stock zirconia abutment. PMID:27476829

  3. Stock Versus CAD/CAM Customized Zirconia Implant Abutments - Clinical and Patient-Based Outcomes in a Randomized Controlled Clinical Trial.

    PubMed

    Schepke, Ulf; Meijer, Henny J A; Kerdijk, Wouter; Raghoebar, Gerry M; Cune, Marco

    2017-02-01

    Single-tooth replacement often requires a prefabricated dental implant and a customized crown. The benefits of individualization of the abutment remain unclear. This randomized controlled clinical trial aims to study potential benefits of individualization of zirconia implant abutments with respect to preservation of marginal bone level and several clinical and patient-based outcome measures. Fifty participants with a missing premolar were included and randomly assigned to standard (ZirDesign, DentsplySirona Implants, Mölndal, Sweden) or computer aided design/computer aided manufacturing (CAD/CAM) customized (Atlantis, DentsplySirona Implants, Mölndal, Sweden) zirconia abutment therapy. Peri-implant bone level (primary outcome), Plaque-index, calculus formation, bleeding on probing, gingiva index, probing pocket depth, recession, appearance of soft tissues and patients' contentment were assessed shortly after placement and one year later. No implants were lost and no complications related to the abutments were observed. Statistically significant differences between stock and CAD/CAM customized zirconia abutments could not be demonstrated for any of the operationalized variables. The use of a CAD/CAM customized zirconia abutment in single tooth replacement of a premolar is not associated with an improvement in clinical performance or patients' contentment when compared to the use of a stock zirconia abutment. © 2016 The Authors. Clinical Implant Dentistry and Related Research Published by Wiley Periodicals, Inc.

  4. Methodology for Benefit Analysis of CAD/CAM (Computer-Aided Design/Computer-Aided Manufacturing) in USN Shipyards.

    DTIC Science & Technology

    1984-03-01

    difference calcula- tion, would result in erroneously lower productivity ratios. Only two topics are not adequately addressed with the method --the first...for determination of this term. 3. CAIDQS P.22li y §easuI~gZ._ Jelbo The next method differs significantly from the previous two in that it deals with...Chasen’s Method (as applied by Lonq Beach M.S.) . . . . . . . o . o . . . . . 31 2. Shah G Yans Method . . . . . . . . . . . 34 3. CARDOS Productivity

  5. Computer-aided rational design of the phosphotransferase system for enhanced glucose uptake in Escherichia coli

    PubMed Central

    Nishio, Yousuke; Usuda, Yoshihiro; Matsui, Kazuhiko; Kurata, Hiroyuki

    2008-01-01

    The phosphotransferase system (PTS) is the sugar transportation machinery that is widely distributed in prokaryotes and is critical for enhanced production of useful metabolites. To increase the glucose uptake rate, we propose a rational strategy for designing the molecular architecture of the Escherichia coli glucose PTS by using a computer-aided design (CAD) system and verified the simulated results with biological experiments. CAD supports construction of a biochemical map, mathematical modeling, simulation, and system analysis. Assuming that the PTS aims at controlling the glucose uptake rate, the PTS was decomposed into hierarchical modules, functional and flux modules, and the effect of changes in gene expression on the glucose uptake rate was simulated to make a rational strategy of how the gene regulatory network is engineered. Such design and analysis predicted that the mlc knockout mutant with ptsI gene overexpression would greatly increase the specific glucose uptake rate. By using biological experiments, we validated the prediction and the presented strategy, thereby enhancing the specific glucose uptake rate. PMID:18197177

  6. Design Through Manufacturing: The Solid Model-Finite Element Analysis Interface

    NASA Technical Reports Server (NTRS)

    Rubin, Carol

    2002-01-01

    State-of-the-art computer aided design (CAD) presently affords engineers the opportunity to create solid models of machine parts reflecting every detail of the finished product. Ideally, in the aerospace industry, these models should fulfill two very important functions: (1) provide numerical. control information for automated manufacturing of precision parts, and (2) enable analysts to easily evaluate the stress levels (using finite element analysis - FEA) for all structurally significant parts used in aircraft and space vehicles. Today's state-of-the-art CAD programs perform function (1) very well, providing an excellent model for precision manufacturing. But they do not provide a straightforward and simple means of automating the translation from CAD to FEA models, especially for aircraft-type structures. Presently, the process of preparing CAD models for FEA consumes a great deal of the analyst's time.

  7. On the Design of a CADS for Shoulder Pain Pathology

    NASA Astrophysics Data System (ADS)

    de Ipiña, K. López; Hernández, M. C.; Martínez, E.; Vaquero, C.

    A musculoskeletal disorder is a condition of the musculoskeletal system, which consists in part of it being injured continuously over time. Shoulder disorders are one of the most common musculoskeletal cases attended in primary health care services. Shoulder disorders cause pain and limit the ability to perform many routine activities, affecting about 15-25 % of the general population. Several clinical tests have been described to aid diagnosis of shoulder disorders. However, the current literature acknowledges a lack of concordance in clinical assessment, even among musculoskeletal specialists. We are working on the design of a Computer-Aided Decision Support (CADS) system for Shoulder Pain Pathology. The paper presents the results of our efforts to build a CADS system testing several classical classification paradigms, feature reduction methods (PCA) and K-means unsupervised clustering. The small database size imposes the use of robust covariance matrix estimation methods to improve the system performance. Finally, the system was evaluated by a medical specialist.

  8. Representing spatial information in a computational model for network management

    NASA Technical Reports Server (NTRS)

    Blaisdell, James H.; Brownfield, Thomas F.

    1994-01-01

    While currently available relational database management systems (RDBMS) allow inclusion of spatial information in a data model, they lack tools for presenting this information in an easily comprehensible form. Computer-aided design (CAD) software packages provide adequate functions to produce drawings, but still require manual placement of symbols and features. This project has demonstrated a bridge between the data model of an RDBMS and the graphic display of a CAD system. It is shown that the CAD system can be used to control the selection of data with spatial components from the database and then quickly plot that data on a map display. It is shown that the CAD system can be used to extract data from a drawing and then control the insertion of that data into the database. These demonstrations were successful in a test environment that incorporated many features of known working environments, suggesting that the techniques developed could be adapted for practical use.

  9. Computer-aided detection in musculoskeletal projection radiography: A systematic review.

    PubMed

    Gundry, M; Knapp, K; Meertens, R; Meakin, J R

    2018-05-01

    To investigated the accuracy of computer-aided detection (CAD) software in musculoskeletal projection radiography via a systematic review. Following selection screening, eligible studies were assessed for bias, and had their study characteristics extracted resulting in 22 studies being included. Of these 22 three studies had tested their CAD software in a clinical setting; the first study investigated vertebral fractures, reporting a sensitivity score of 69.3% with CAD, compared to 59.8% sensitivity without CAD. The second study tested dental caries diagnosis producing a sensitivity score of 68.8% and specificity of 94.1% with CAD, compared to sensitivity of 39.3% and specificity of 96.7% without CAD. The third indicated osteoporotic cases based on CAD, resulting in 100% sensitivity and 81.3% specificity. The current evidence reported shows a lack of development into the clinical testing phase; however the research does show future promise in the variation of different CAD systems. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  10. Can computer-aided diagnosis (CAD) help radiologists find mammographically missed screening cancers?

    NASA Astrophysics Data System (ADS)

    Nishikawa, Robert M.; Giger, Maryellen L.; Schmidt, Robert A.; Papaioannou, John

    2001-06-01

    We present data from a pilot observer study whose goal is design a study to test the hypothesis that computer-aided diagnosis (CAD) can improve radiologists' performance in reading screening mammograms. In a prospective evaluation of our computer detection schemes, we have analyzed over 12,000 clinical exams. Retrospective review of the negative screening mammograms for all cancer cases found an indication of the cancer in 23 of these negative cases. The computer found 54% of these in our prospective testing. We added to these cases normal exams to create a dataset of 75 cases. Four radiologists experienced in mammography read the cases and gave their BI-RADS assessment and their confidence that the patient should be called back for diagnostic mammography. They did so once reading the films only and a second time reading with the computer aid. Three radiologists had no change in area under the ROC curve (mean Az of 0.73) and one improved from 0.73 to 0.78, but this difference failed to reach statistical significance (p equals 0.23). These data are being used to plan a larger more powerful study.

  11. Image Processing and Computer Aided Diagnosis in Computed Tomography of the Breast

    DTIC Science & Technology

    2007-03-01

    TERMS breast imaging, breast CT, scatter compensation, denoising, CAD , Cone-beam CT 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF...clinical projection images. The CAD tool based on signal known exactly (SKE) scenario is under development. Task 6: Test and compare the...performances of the CAD developed in Task 5 applied to processed projection data from Task 1 with the CAD performance on the projection data without Bayesian

  12. Distortion of CAD-CAM-fabricated implant-fixed titanium and zirconia complete dental prosthesis frameworks.

    PubMed

    Al-Meraikhi, Hadi; Yilmaz, Burak; McGlumphy, Edwin; Brantley, William A; Johnston, William M

    2018-01-01

    Computer-aided design and computer-aided manufacturing (CAD-CAM)-fabricated titanium and zirconia implant-supported fixed dental prostheses have become increasingly popular for restoring patients with complete edentulism. However, the distortion level of these frameworks is not well known. The purpose of this in vitro study was to compare the 3-dimensional (3D) distortion of CAD-CAM zirconia and titanium implant-fixed screw-retained complete dental prostheses. A master edentulous model with 4 implants at the positions of the maxillary first molars and canines was used. Multiunit abutments (Nobel Biocare) secured to the model were digitally scanned using scan bodies and a laboratory scanner (S600 ARTI; Zirkonzahn). Titanium (n=5) and zirconia (n=5) frameworks were milled using a CAD-CAM system (Zirkonzahn M1; Zirkonzahn). All frameworks were scanned using an industrial computed tomography (CT) scanner (Nikon/X-Tek XT H 225kV MCT Micro-Focus). The direct CT scans were reconstructed to generate standard tessellation language (STL) files. To calculate the 3D distortion of the frameworks, STL files of the CT scans were aligned to the CAD model using a sum of the least squares best-fit algorithm. Surface comparison points were placed on the CAD model on the midfacial aspect of all teeth. The 3D distortion of each direct scan to the CAD model was calculated. In addition, color maps of the scan-to-CAD comparison were constructed using a ±0.500 mm color scale range. Both materials exhibited distortion; however, no significant difference was found in the amount of distortion from the CAD model between the materials (P=.747). Absolute values of deviations from the CAD model were evident in the x and y plane and less so in the z direction. Zirconia and titanium frameworks showed similar 3D distortion compared with the CAD model for the tested CAD-CAM and implant systems. The distortion was more pronounced in the horizontal and sagittal plane than in the vertical plane. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  13. Computer-aided design evaluation of harvestable mandibular bone volume: a clinical and tomographic human study.

    PubMed

    Verdugo, Fernando; Simonian, Krikor; Raffaelli, Luca; D'Addona, Antonio

    2014-06-01

    To evaluate and compare the volume of bone graft material that can be safely harvested from the mandibular symphysis and rami using a computer-aided design (CAD) software program. Preoperative computerized tomography scans from 40 patients undergoing bone augmentation procedures were analyzed. Symphysis and rami cross sections were mapped using a CAD software program (AutoCAD(®), Autodesk, Inc., San Rafael, CA, USA) to evaluate the bone volume that can be safely harvested. CAD calculations were contrasted to intrasurgical measurements in a subgroup of 20 individuals. CAD calculations yielded a safe harvestable osseous volume of 1.44 cm(3) ± 0.49 for the symphysis and 0.82 cm(3) ± 0.21 for each ramus (p < .0001, confidence interval [CI] 95%: 0.47-0.78). These measurements were significantly lower (p < .0001) than the bone volumes harvested intrasurgically for both symphysis and ramus, respectively (2.40 cm(3) ± 0.50 vs. 2.65 cm(3) ± 0.45). CAD calculations of harvestable symphysis and ramus bone translated into an average of 2.40 cm(3) ± 0.50 (range: 1.80-3.10 cm(3)) and 2.65 cm(3) ± 0.45 (range: 1.90-3.50) of particulate bone graft intrasurgically, respectively. Ramus cortical was significantly thicker than the symphysis cortical, 2.9 ± 0.4 mm versus 2.19 mm ± 0.4 mm (p < .0001, CI 95%: 0.45-1.03). The symphysis and rami are good harvesting sources to obtain dense corticocancellous bone. The significant volumetric CAD differences between the symphysis and ramus seem to balance out intrasurgically and may be due to the greater cortical bone volume at the ramus area. It is plausible to harvest an average of 7.70 cm(3) from the symphysis and rami alone. The use of a CAD software program can enhance surgical treatment planning prior to bone transplantation. © 2012 Wiley Periodicals, Inc.

  14. Marginal fit of all-ceramic crowns fabricated using two extraoral CAD/CAM systems in comparison with the conventional technique

    PubMed Central

    Alqahtani, Fawaz

    2017-01-01

    Objective The purpose of this study was to determine the effect of two extraoral computer-aided design (CAD) and computer-aided manufacturing (CAM) systems, in comparison with conventional techniques, on the marginal fit of monolithic CAD/CAM lithium disilicate ceramic crowns. Study design This is an in vitro interventional study. Place and duration of study The study was carried out at the Department of Prosthodontics, School of Dentistry, Prince Sattam Bin Abdul-Aziz University, Saudi Arabia, from December 2015 to April 2016. Methodology A marginal gap of 60 lithium disilicate crowns was evaluated by scanning electron microscopy. In total, 20 pressable lithium disilicate (IPS e.max Press [Ivoclar Vivadent]) ceramic crowns were fabricated using the conventional lost-wax technique as a control group. The experimental all-ceramic crowns were produced based on a scan stone model and milled using two extraoral CAD/CAM systems: the Cerec group was fabricated using the Cerec CAD/CAM system, and the Trios group was fabricated using Trios CAD and milled using Wieland Zenotec CAM. One-way analysis of variance (ANOVA) and the Scheffe post hoc test were used for statistical comparison of the groups (α=0.05). Results The mean (±standard deviation) of the marginal gap of each group was as follows: the Control group was 91.15 (±15.35) µm, the Cerec group was 111.07 (±6.33) µm, and the Trios group was 60.17 (±11.09) µm. One-way ANOVA and the Scheffe post hoc test showed a statistically significant difference in the marginal gap between all groups. Conclusion It can be concluded from the current study that all-ceramic crowns, fabricated using the CAD/CAM system, show a marginal accuracy that is acceptable in clinical environments. The Trios CAD group displayed the smallest marginal gap. PMID:28352204

  15. Analog Computer-Aided Detection (CAD) information can be more effective than binary marks

    PubMed Central

    Cunningham, Corbin A.; Drew, Trafton; Wolfe, Jeremy M.

    2017-01-01

    In socially important visual search tasks such as baggage screening and diagnostic radiology, experts miss more targets than is desirable. Computer Aided Detection (CAD) programs have been developed specifically to help improve performance in these professional search tasks. For example, in breast cancer screening, many CAD systems are capable of detecting approximately 90% of breast cancer, with approximately 0.5 false positive detections per image. Nevertheless, benefits of CAD in clinical settings tend to be small (Birdwell, 2009) or even absent (Meziane et al., 2011; Philpotts, 2009). The marks made by a CAD system can be “Binary”, giving the same signal to any location where the signal is above some threshold. Alternatively, a CAD system present an Analog signal that reflected strength of the signal at a location. In the experiments reported here, we compare analog and binary CAD presentations using non-expert observers and artificial stimuli defined by two noisy signals: a visible color signal and an "invisible" signal that informed our simulated CAD system. We found that analog CAD generally yielded better overall performance than binary CAD. The analog benefit is similar at high and low target prevalence. Our data suggest that the form of the CAD signal can directly influence performance. Analog CAD may allow the computer to be more helpful to the searcher. PMID:27928658

  16. A tool to convert CAD models for importation into Geant4

    NASA Astrophysics Data System (ADS)

    Vuosalo, C.; Carlsmith, D.; Dasu, S.; Palladino, K.; LUX-ZEPLIN Collaboration

    2017-10-01

    The engineering design of a particle detector is usually performed in a Computer Aided Design (CAD) program, and simulation of the detector’s performance can be done with a Geant4-based program. However, transferring the detector design from the CAD program to Geant4 can be laborious and error-prone. SW2GDML is a tool that reads a design in the popular SOLIDWORKS CAD program and outputs Geometry Description Markup Language (GDML), used by Geant4 for importing and exporting detector geometries. Other methods for outputting CAD designs are available, such as the STEP format, and tools exist to convert these formats into GDML. However, these conversion methods produce very large and unwieldy designs composed of tessellated solids that can reduce Geant4 performance. In contrast, SW2GDML produces compact, human-readable GDML that employs standard geometric shapes rather than tessellated solids. This paper will describe the development and current capabilities of SW2GDML and plans for its enhancement. The aim of this tool is to automate importation of detector engineering models into Geant4-based simulation programs to support rapid, iterative cycles of detector design, simulation, and optimization.

  17. Split-mouth comparison of the accuracy of computer-generated and conventional surgical guides.

    PubMed

    Farley, Nathaniel E; Kennedy, Kelly; McGlumphy, Edwin A; Clelland, Nancy L

    2013-01-01

    Recent clinical studies have shown that implant placement is highly predictable with computer-generated surgical guides; however, the reliability of these guides has not been compared to that of conventional guides clinically. This study aimed to compare the accuracy of reproducing planned implant positions with computer-generated and conventional surgical guides using a split-mouth design. Ten patients received two implants each in symmetric locations. All implants were planned virtually using a software program and information from cone beam computed tomographic scans taken with scan appliances in place. Patients were randomly selected for computer-aided design/computer-assisted manufacture (CAD/CAM)-guided implant placement on their right or left side. Conventional guides were used on the contralateral side. Patients underwent operative cone beam computed tomography postoperatively. Planned and actual implant positions were compared using three-dimensional analyses capable of measuring volume overlap as well as differences in angles and coronal and apical positions. Results were compared using a mixed-model repeated-measures analysis of variance and were further analyzed using a Bartlett test for unequal variance (α = .05). Implants placed with CAD/CAM guides were closer to the planned positions in all eight categories examined. However, statistically significant differences were shown only for coronal horizontal distances. It was also shown that CAD/CAM guides had less variability than conventional guides, which was statistically significant for apical distance. Implants placed using CAD/CAM surgical guides provided greater accuracy in a lateral direction than conventional guides. In addition, CAD/CAM guides were more consistent in their deviation from the planned locations than conventional guides.

  18. Ares Upper Stage Processes to Implement Model Based Design - Going Paperless

    NASA Technical Reports Server (NTRS)

    Gregory, Melanie

    2012-01-01

    Computer-Aided Design (CAD) has all but replaced the drafting board for design work. Increased productivity and accuracy should be natural outcomes of using CAD. Going from paper drawings only to paper drawings based on CAD models to CAD models and no drawings, or Model Based Design (MBD), is a natural progression in today?s world. There are many advantages to MBD over traditional design methods. To make the most of those advantages, standards should be in place and the proper foundation should be laid prior to transitioning to MBD. However, without a full understanding of the implications of MBD and the proper control of the data, the advantages are greatly diminished. Transitioning from a paper design world to an electronic design world means re-thinking how information gets controlled at its origin and distributed from one point to another. It means design methodology is critical, especially for large projects. It means preparation of standardized parts and processes as well as strong communication between all parties in order to maximize the benefits of MBD.

  19. Fracture Rates and Lifetime Estimations of CAD/CAM All-ceramic Restorations.

    PubMed

    Belli, R; Petschelt, A; Hofner, B; Hajtó, J; Scherrer, S S; Lohbauer, U

    2016-01-01

    The gathering of clinical data on fractures of dental restorations through prospective clinical trials is a labor- and time-consuming enterprise. Here, we propose an unconventional approach for collecting large datasets, from which clinical information on indirect restorations can be retrospectively analyzed. The authors accessed the database of an industry-scale machining center in Germany and obtained information on 34,911 computer-aided design (CAD)/computer-aided manufacturing (CAM) all-ceramic posterior restorations. The fractures of bridges, crowns, onlays, and inlays fabricated from different all-ceramic systems over a period of 3.5 y were reported by dentists and entered in the database. Survival analyses and estimations of future life revealed differences in performance among ZrO2-based restorations and lithium disilicate and leucite-reinforced glass-ceramics. © International & American Associations for Dental Research 2015.

  20. A Switching-Mode Power Supply Design Tool to Improve Learning in a Power Electronics Course

    ERIC Educational Resources Information Center

    Miaja, P. F.; Lamar, D. G.; de Azpeitia, M.; Rodriguez, A.; Rodriguez, M.; Hernando, M. M.

    2011-01-01

    The static design of ac/dc and dc/dc switching-mode power supplies (SMPS) relies on a simple but repetitive process. Although specific spreadsheets, available in various computer-aided design (CAD) programs, are widely used, they are difficult to use in educational applications. In this paper, a graphic tool programmed in MATLAB is presented,…

  1. Medical imaging and computers in the diagnosis of breast cancer

    NASA Astrophysics Data System (ADS)

    Giger, Maryellen L.

    2014-09-01

    Computer-aided diagnosis (CAD) and quantitative image analysis (QIA) methods (i.e., computerized methods of analyzing digital breast images: mammograms, ultrasound, and magnetic resonance images) can yield novel image-based tumor and parenchyma characteristics (i.e., signatures that may ultimately contribute to the design of patient-specific breast cancer management plans). The role of QIA/CAD has been expanding beyond screening programs towards applications in risk assessment, diagnosis, prognosis, and response to therapy as well as in data mining to discover relationships of image-based lesion characteristics with genomics and other phenotypes; thus, as they apply to disease states. These various computer-based applications are demonstrated through research examples from the Giger Lab.

  2. [Numerical finite element modeling of custom car seat using computer aided design].

    PubMed

    Huang, Xuqi; Singare, Sekou

    2014-02-01

    A good cushion can not only provide the sitter with a high comfort, but also control the distribution of the hip pressure to reduce the incidence of diseases. The purpose of this study is to introduce a computer-aided design (CAD) modeling method of the buttocks-cushion using numerical finite element (FE) simulation to predict the pressure distribution on the buttocks-cushion interface. The buttock and the cushion model geometrics were acquired from a laser scanner, and the CAD software was used to create the solid model. The FE model of a true seated individual was developed using ANSYS software (ANSYS Inc, Canonsburg, PA). The model is divided into two parts, i.e. the cushion model made of foam and the buttock model represented by the pelvis covered with a soft tissue layer. Loading simulations consisted of imposing a vertical force of 520N on the pelvis, corresponding to the weight of the user upper extremity, and then solving iteratively the system.

  3. CREW CHIEF: A computer graphics simulation of an aircraft maintenance technician

    NASA Technical Reports Server (NTRS)

    Aume, Nilss M.

    1990-01-01

    Approximately 35 percent of the lifetime cost of a military system is spent for maintenance. Excessive repair time is caused by not considering maintenance during design. Problems are usually discovered only after a mock-up has been constructed, when it is too late to make changes. CREW CHIEF will reduce the incidence of such problems by catching design defects in the early design stages. CREW CHIEF is a computer graphic human factors evaluation system interfaced to commercial computer aided design (CAD) systems. It creates a three dimensional man model, either male or female, large or small, with various types of clothing and in several postures. It can perform analyses for physical accessibility, strength capability with tools, visual access, and strength capability for manual materials handling. The designer would produce a drawing on his CAD system and introduce CREW CHIEF in it. CREW CHIEF's analyses would then indicate places where problems could be foreseen and corrected before the design is frozen.

  4. Can Tooth Preparation Design Affect the Fit of CAD/CAM Restorations?

    PubMed

    Roperto, Renato Cassio; Oliveira, Marina Piolli; Porto, Thiago Soares; Ferreira, Lais Alaberti; Melo, Lucas Simino; Akkus, Anna

    2017-03-01

    The purpose of this study was to evaluate if the marginal fit of computer-aided design and computer-aided manufacturing (CAD/CAM) restorations manufactured with CAD/CAM systems can be affected by different tooth preparation designs. Twenty-six typodont (plastic) teeth were divided into two groups (n = 13) according to the occlusal curvature of the tooth preparation. These were the group 1 (control group) (flat occlusal design) and group 2 (curved occlusal design). Scanning of the preparations was performed, and crowns were milled using ceramic blocks. Blocks were cemented using epoxy glue on the pulpal floor only, and finger pressure was applied for 1 minute. On completion of the cementation step, poor fits between the restoration and abutment were measured by microphotography and the silicone replica technique using light-body silicon material on mesial, distal, buccal, and lingual surfaces. Two-way ANOVA analysis did not reveal a statistical difference between flat (83.61 ± 50.72) and curved (79.04 ± 30.97) preparation designs. Buccal, mesial, lingual, and distal sites on the curved design preparation showed less of a gap when compared with flat design. No difference was found on flat preparations among mesial, buccal, and distal sites (P < .05). The lingual aspect had no difference from the distal side but showed a statistically significant difference from mesial and buccal (P < .05). Difference in occlusal design did not significantly impact the marginal fit. Marginal fit was significantly affected by the location of the margin; lingual and distal locations exhibited greater margin gap values compared with buccal and mesial sites regardless of the preparation design.

  5. Effects of tributylborane-activated adhesive and two silane agents on bonding computer-aided design and manufacturing (CAD/CAM) resin composite.

    PubMed

    Shinohara, Ayano; Taira, Yohsuke; Sawase, Takashi

    2017-10-01

    The present study was conducted to evaluate the effects of an experimental adhesive agent [methyl methacrylate-tributylborane liquid (MT)] and two adhesive agents containing silane on the bonding between a resin composite block of a computer-aided design and manufacturing (CAD/CAM) system and a light-curing resin composite veneering material. The surfaces of CAD/CAM resin composite specimens were ground with silicon-carbide paper, treated with phosphoric acid, and then primed with either one of the two silane agents [Scotchbond Universal Adhesive (SC) and GC Ceramic Primer II (GC)], no adhesive control (Cont), or one of three combinations (MT/SC, MT/GC, and MT/Cont). A light-curing resin composite was veneered on the primed CAD/CAM resin composite surface. The veneered specimens were subjected to thermocycling between 4 and 60 °C for 10,000 cycles, and the shear bond strengths were determined. All data were analyzed using analysis of variance and a post hoc Tukey-Kramer HSD test (α = 0.05, n = 8). MT/SC (38.7 MPa) exhibited the highest mean bond strengths, followed by MT/GC (30.4 MPa), SC (27.9 MPa), and MT/Cont (25.7 MPa), while Cont (12.9 MPa) and GC (12.3 MPa) resulted in the lowest bond strengths. The use of MT in conjunction with a silane agent significantly improved the bond strength. Surface treatment with appropriate adhesive agents was confirmed as a prerequisite for veneering CAD/CAM resin composite restorations.

  6. Assessment of the fit of removable partial denture fabricated by computer-aided designing/computer aided manufacturing technology.

    PubMed

    Arafa, Khalid A O

    2018-01-01

    To assess the level of evidence that supports the quality of fit for removable partial denture (RPD) fabricated by computer-aided designing/computer aided manufacturing (CAD/CAM) and rapid prototyping (RP) technology. Methods: An electronic search was performed in Google Scholar, PubMed, and Cochrane library search engines, using Boolean operators. All articles published in English and published in the period from 1950 until April 2017 were eligible to be included in this review. The total number of articles contained the search terms in any part of the article (including titles, abstracts, or article texts) were screened, which resulted in 214 articles. After exclusion of irrelevant and duplicated articles, 12 papers were included in this systematic review.  Results: All the included studies were case reports, except one study, which was a case series that recruited 10 study participants. The visual and tactile examination in the cast or clinically in the patient's mouth was the most-used method for assessment of the fit of RPDs. From all included studies, only one has assessed the internal fit between RPDs and oral tissues using silicone registration material. The vast majority of included studies found that the fit of RPDs ranged from satisfactory to excellent fit. Conclusion: Despite the lack of clinical trials that provide strong evidence, the available evidence supported the claim of good fit of RPDs fabricated by new technologies using CAD/CAM.

  7. PACS-Based Computer-Aided Detection and Diagnosis

    NASA Astrophysics Data System (ADS)

    Huang, H. K. (Bernie); Liu, Brent J.; Le, Anh HongTu; Documet, Jorge

    The ultimate goal of Picture Archiving and Communication System (PACS)-based Computer-Aided Detection and Diagnosis (CAD) is to integrate CAD results into daily clinical practice so that it becomes a second reader to aid the radiologist's diagnosis. Integration of CAD and Hospital Information System (HIS), Radiology Information System (RIS) or PACS requires certain basic ingredients from Health Level 7 (HL7) standard for textual data, Digital Imaging and Communications in Medicine (DICOM) standard for images, and Integrating the Healthcare Enterprise (IHE) workflow profiles in order to comply with the Health Insurance Portability and Accountability Act (HIPAA) requirements to be a healthcare information system. Among the DICOM standards and IHE workflow profiles, DICOM Structured Reporting (DICOM-SR); and IHE Key Image Note (KIN), Simple Image and Numeric Report (SINR) and Post-processing Work Flow (PWF) are utilized in CAD-HIS/RIS/PACS integration. These topics with examples are presented in this chapter.

  8. Machine Learning in Ultrasound Computer-Aided Diagnostic Systems: A Survey

    PubMed Central

    Zhang, Fan; Li, Xuelong

    2018-01-01

    The ultrasound imaging is one of the most common schemes to detect diseases in the clinical practice. There are many advantages of ultrasound imaging such as safety, convenience, and low cost. However, reading ultrasound imaging is not easy. To support the diagnosis of clinicians and reduce the load of doctors, many ultrasound computer-aided diagnosis (CAD) systems are proposed. In recent years, the success of deep learning in the image classification and segmentation led to more and more scholars realizing the potential of performance improvement brought by utilizing the deep learning in the ultrasound CAD system. This paper summarized the research which focuses on the ultrasound CAD system utilizing machine learning technology in recent years. This study divided the ultrasound CAD system into two categories. One is the traditional ultrasound CAD system which employed the manmade feature and the other is the deep learning ultrasound CAD system. The major feature and the classifier employed by the traditional ultrasound CAD system are introduced. As for the deep learning ultrasound CAD, newest applications are summarized. This paper will be useful for researchers who focus on the ultrasound CAD system. PMID:29687000

  9. Computer-aided diagnosis: A survey with bibliometric analysis.

    PubMed

    Takahashi, Ryohei; Kajikawa, Yuya

    2017-05-01

    Computer-aided diagnosis (CAD) has been a promising area of research over the last two decades. However, CAD is a very complicated subject because it involves a number of medicine and engineering-related fields. To develop a research overview of CAD, we conducted a literature survey with bibliometric analysis, which we report here. Our study determined that CAD research has been classified and categorized according to disease type and imaging modality. This classification began with the CAD of mammograms and eventually progressed to that of brain disease. Furthermore, based on our results, we discuss future directions and opportunities for CAD research. First, in contrast to the typical hypothetical approach, the data-driven approach has shown promise. Second, the normalization of the test datasets and an evaluation method is necessary when adopting an algorithm and a system. Third, we discuss opportunities for the co-evolution of CAD research and imaging instruments-for example, the CAD of bones and pancreatic cancer. Fourth, the potential of synergy with CAD and clinical decision support systems is also discussed. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Machine Learning in Ultrasound Computer-Aided Diagnostic Systems: A Survey.

    PubMed

    Huang, Qinghua; Zhang, Fan; Li, Xuelong

    2018-01-01

    The ultrasound imaging is one of the most common schemes to detect diseases in the clinical practice. There are many advantages of ultrasound imaging such as safety, convenience, and low cost. However, reading ultrasound imaging is not easy. To support the diagnosis of clinicians and reduce the load of doctors, many ultrasound computer-aided diagnosis (CAD) systems are proposed. In recent years, the success of deep learning in the image classification and segmentation led to more and more scholars realizing the potential of performance improvement brought by utilizing the deep learning in the ultrasound CAD system. This paper summarized the research which focuses on the ultrasound CAD system utilizing machine learning technology in recent years. This study divided the ultrasound CAD system into two categories. One is the traditional ultrasound CAD system which employed the manmade feature and the other is the deep learning ultrasound CAD system. The major feature and the classifier employed by the traditional ultrasound CAD system are introduced. As for the deep learning ultrasound CAD, newest applications are summarized. This paper will be useful for researchers who focus on the ultrasound CAD system.

  11. Teaching CAD at the University: Specifically Written or Commercial Software?

    ERIC Educational Resources Information Center

    Garcia, Ramon Rubio; Quiros, Javier Suarez; Santos, Ramon Gallego; Penin, Pedro I. Alvarez

    2007-01-01

    At most universities throughout the world Computer Aided Design is taught using commercial programs more suitable for business and industry than for teaching. This led us to write our own design program (GIcad) starting from the best-known standards on the market, but always avoiding unnecessary commands in the first steps of the learning process.…

  12. Effect of professional dental prophylaxis on the surface gloss and roughness of CAD/CAM restorative materials.

    PubMed

    Sugiyama, Toshiko; Kameyama, Atsushi; Enokuchi, Tomoka; Haruyama, Akiko; Chiba, Aoi; Sugiyama, Setsuko; Hosaka, Makoto; Takahashi, Toshiyuki

    2017-06-01

    This study aimed to evaluate the effect of dental prophylaxis on the surface gloss and roughness of different indirect restorative materials for computer-aided design/computer-aided manufacturing (CAD/CAM): two types of CAD/CAM composite resin blocks (Shofu Block HC and Estelite Block) and two types of CAD/CAM ceramic blocks (IPS Empress CAD and Celtra DUO). After polishing the CAD/CAM blocks and applying prophylaxis pastes, professional dental prophylaxis was performed using four different experimental protocols (n = 5 each): mechanical cleaning with Merssage Regular for 10 s four times (Group 1); four cycles of mechanical cleaning with Merssage Regular for 10 s and Merssage Fine for 10 s (Group 2); four cycles of mechanical cleaning with Merssage Regular for 10 s and Merssage Fine for 30 s (Group 3); and mechanical cleaning with Merssage Fine for 10 s four times (Group 4). A glossmeter was used to measure surface gloss before and after mechanical cleaning, and a contact stylus profilometer was used to measure surface roughness (Ra). Polishing with prophylactic paste led to a significant reduction in surface gloss and increase in surface roughness among resin composite blocks, whereas the polishing-related change in surface gloss or roughness was smaller in Celtra DUO, a zirconia-reinforced lithium silicate block. Changes in surface gloss and roughness due to polishing with a prophylactic paste containing large particles were not improved by subsequent polishing with a prophylactic paste containing fine particles. Key words: CAD/CAM, professional dental prophylaxis, prophylactic paste, surface gloss, surface roughness.

  13. Effect of professional dental prophylaxis on the surface gloss and roughness of CAD/CAM restorative materials

    PubMed Central

    Sugiyama, Toshiko; Enokuchi, Tomoka; Haruyama, Akiko; Chiba, Aoi; Sugiyama, Setsuko; Hosaka, Makoto; Takahashi, Toshiyuki

    2017-01-01

    Background This study aimed to evaluate the effect of dental prophylaxis on the surface gloss and roughness of different indirect restorative materials for computer-aided design/computer-aided manufacturing (CAD/CAM): two types of CAD/CAM composite resin blocks (Shofu Block HC and Estelite Block) and two types of CAD/CAM ceramic blocks (IPS Empress CAD and Celtra DUO). Material and Methods After polishing the CAD/CAM blocks and applying prophylaxis pastes, professional dental prophylaxis was performed using four different experimental protocols (n = 5 each): mechanical cleaning with Merssage Regular for 10 s four times (Group 1); four cycles of mechanical cleaning with Merssage Regular for 10 s and Merssage Fine for 10 s (Group 2); four cycles of mechanical cleaning with Merssage Regular for 10 s and Merssage Fine for 30 s (Group 3); and mechanical cleaning with Merssage Fine for 10 s four times (Group 4). A glossmeter was used to measure surface gloss before and after mechanical cleaning, and a contact stylus profilometer was used to measure surface roughness (Ra). Results Polishing with prophylactic paste led to a significant reduction in surface gloss and increase in surface roughness among resin composite blocks, whereas the polishing-related change in surface gloss or roughness was smaller in Celtra DUO, a zirconia-reinforced lithium silicate block. Conclusions Changes in surface gloss and roughness due to polishing with a prophylactic paste containing large particles were not improved by subsequent polishing with a prophylactic paste containing fine particles. Key words:CAD/CAM, professional dental prophylaxis, prophylactic paste, surface gloss, surface roughness. PMID:28638554

  14. Comparison of Marginal and Internal Adaptation of CAD/CAM and Conventional Cement Retained Implant-Supported Single Crowns.

    PubMed

    Nejatidanesh, Farahnaz; Shakibamehr, Amir Hossein; Savabi, Omid

    2016-02-01

    To evaluate the accuracy of marginal and internal adaptation of 2 computer-aided design/computer-aided manufacturing (CAD/CAM) and 2 conventionally made cement retained implant-supported restorations. An abutment and its corresponding fixture analog (Astra Tech) were inserted in left central incisor area of a maxillary cast. Four types of implant-supported single restorations were fabricated on the abutment (n = 10): e.max CAD (Cerec AC system), zirconia-based (Cercon system), IPS e.max Press, and metal-ceramic restorations. The internal and marginal gaps of the studied groups were measured by replica method and stereomicroscope. Data were subjected to 1-way ANOVA and Scheffe post hoc tests (α = 0.05). Mean internal gaps of Cercon (59.48 ± 16.49 μm) and e.max Press (75.62 ± 26.92 μm) groups were significantly different from e.max CAD (120.29 ± 16.74 μm) group, but there was no significant difference between metal-ceramic restorations (89.65 ± 47.84 μm) and e.max CAD. The marginal gaps of e.max CAD (32.02 ± 10.38 μm) and Cercon restorations (34.26 ± 11.41 μm) were significantly superior from metal ceramics (59.19 ± 17.81 μm) and e.max press (74.99 ± 24.51 μm). Within the limitations of this study, it can be concluded that although the marginal and internal gaps of the studied implant-supported restorations were in the clinically acceptable range, single crowns made with CAD/CAM technology provide better marginal fit.

  15. Computer-aided system for diagnosing thyroid nodules on ultrasound: A comparison with radiologist-based clinical assessments.

    PubMed

    Gao, Luying; Liu, Ruyu; Jiang, Yuxin; Song, Wenfeng; Wang, Ying; Liu, Jia; Wang, Juanjuan; Wu, Dongqian; Li, Shuai; Hao, Aimin; Zhang, Bo

    2018-04-01

    The purpose of this study was to compare the diagnostic efficiency of a thyroid ultrasound computer-aided diagnosis (CAD) system with that of 1 radiologist. This study retrospectively reviewed 342 surgically resected thyroid nodules from July 2013 to December 2013 at our center. The nodules were assessed on typical ultrasound images using the CAD system and reviewed by 1 experienced radiologist. The radiologist stratified the risk of malignancy using the Thyroid Imaging Reporting and Data Systems (TIRADS) and the American Thyroid Association (ATA) guidelines. The radiologist, using TI-RADS and ATA guidelines, performed better than the CAD system (P < .01). The sensitivity of the CAD system was similar to that of an experienced radiologist (P > .05; P < .01; and P > .05). However, we found that the CAD system had lower specificity (P < .01). The sensitivity of a thyroid ultrasound CAD system in differentiating nodules was similar to that of an experienced radiologist. However, the CAD system had lower specificity. © 2017 Wiley Periodicals, Inc.

  16. Engineering specification and system design for CAD/CAM of custom shoes: UMC project effort

    NASA Technical Reports Server (NTRS)

    Bao, Han P.

    1991-01-01

    The goal of this project is to supplement the footwear design system of North Carolina State University (NCSU) with a software module to design and manufacture a combination sole. The four areas of concentration were: customization of NASCAD (NASA Computer Aided Design) to the footwear project; use of CENCIT data; computer aided manufacturing activities; and beginning work for the bottom elements of shoes. The task of generating a software module for producing a sole was completed with a demonstrated product realization. The software written in C was delivered to NCSU for inclusion in their design system for custom footwear known as LASTMOD. The machining process of the shoe last was improved using a spiral tool path approach.

  17. A citizen science approach to optimising computer aided detection (CAD) in mammography

    NASA Astrophysics Data System (ADS)

    Ionescu, Georgia V.; Harkness, Elaine F.; Hulleman, Johan; Astley, Susan M.

    2018-03-01

    Computer aided detection (CAD) systems assist medical experts during image interpretation. In mammography, CAD systems prompt suspicious regions which help medical experts to detect early signs of cancer. This is a challenging task and prompts may appear in regions that are actually normal, whilst genuine cancers may be missed. The effect prompting has on readers performance is not fully known. In order to explore the effects of prompting errors, we have created an online game (Bat Hunt), designed for non-experts, that mirrors mammographic CAD. This allows us to explore a wider parameter space. Users are required to detect bats in images of flocks of birds, with image difficulty matched to the proportions of screening mammograms in different BI-RADS density categories. Twelve prompted conditions were investigated, along with unprompted detection. On average, players achieved a sensitivity of 0.33 for unprompted detection, and sensitivities of 0.75, 0.83, and 0.92 respectively for 70%, 80%, and 90% of targets prompted, regardless of CAD specificity. False prompts distract players from finding unprompted targets if they appear in the same image. Player performance decreases when the number of false prompts increases, and increases proportionally with prompting sensitivity. Median lowest d' was for unprompted condition (1.08) and the highest for sensitivity 90% and 0.5 false prompts per image (d'=4.48).

  18. CAD/CAM techniques help in the rebuilding of ideal marginal gingiva contours of anterior maxillary teeth: A case report.

    PubMed

    Yin, Jiayue; Liu, Dan; Huang, Yuehua; Wu, Lin; Tang, Xiaolin

    2017-11-01

    "Pink esthetics," which are considered to be as important as "white esthetics," have attracted increasing attention. To date, clinicians rarely have applied computer-aided design and computer-aided manufacturing (CAD/CAM) techniques in the rebuilding of the contour of the marginal gingiva in the esthetic zone. In this case report, the authors describe a female patient who had gingival inflammation and an asymmetrical contour of the marginal gingiva of the anterior maxillary teeth because previously placed ceramic crowns violated the biological width. The authors used a 3-dimensional-printing surgery template to guide precise crown-lengthening surgery to expose subgingival shoulders and to obtain an ideal marginal gingival contour. Then the authors used interim CAD/CAM crowns to induce the growth of the interdental papilla by 0.5 to 1.5 millimeters. Finally, the patient had a symmetrical and well-balanced contour of the marginal gingiva. In addition, the authors reduced the patient's "black triangle" areas to the greatest possible extent. This case report illustrates that CAD/CAM products, including 3-dimensional-printing surgery templates and CAD/CAM interim crowns, are helpful in shaping and rebuilding the ideal contour of the marginal gingiva in the esthetic zone, such as the anterior maxillary teeth. Copyright © 2017 American Dental Association. Published by Elsevier Inc. All rights reserved.

  19. Simulation of materials processing: Fantasy or reality?

    NASA Technical Reports Server (NTRS)

    Jenkins, Thomas J.; Bright, Victor M.

    1994-01-01

    This experiment introduces students to the application of computer-aided design (CAD) and analysis of materials processing in the context of integrated circuit (IC) fabrication. The fabrication of modern IC's is a complex process which consists of several sequential steps. These steps involve the precise control of processing variables such as temperature, humidity, and ambient gas composition. In essence, the particular process employed during the fabrication becomes a 'recipe'. Due to economic and other considerations, CAD is becoming an indispensable part of the development of new recipes for IC fabrication. In particular, this experiment permits the students to explore the CAD of the thermal oxidation of silicon.

  20. Marginal accuracy of computer-aided design- and computer-aided manufacturing-fabricated full-arch zirconia restoration.

    PubMed

    Juntavee, Niwut; Sirisathit, Issarawas

    2018-01-01

    This study evaluated marginal accuracy of full-arch zirconia restoration fabricated from two digital computer-aided design and computer-aided manufacturing (CAD-CAM) systems (Trios-3 and CS3500) in comparison to conventional cast metal restoration. A stainless steel model comprising two canine and two molar abutments was used as a master model for full-arch reconstruction. The canine and molar abutments were machined in a cylindrical shape with 5° taper and chamfer margin. The CAD-CAM systems based on the digital approach were used to construct the full-arch zirconia restoration. The conventional cast metal restoration was fabricated according to a conventional lost-wax technique using nickel-chromium alloys. Ten restorations were fabricated from each system. The marginal accuracy of each restoration was determined at four locations for each abutment. An analysis of variance (ANOVA) and Tukey's honest significant difference (HSD) multiple comparisons were used to determine statistically significant difference at 95% confidence interval. The mean values of marginal accuracy of restorations fabricated from conventional casting, Trios-3, and CS3500 were 48.59±4.16 μm, 53.50±5.66 μm, and 56.47±5.52 μm, respectively. ANOVA indicated significant difference in marginal fit of restorations among various systems. The marginal discrepancy of zirconia restoration fabricated from the CS3500 system demonstrated significantly larger gap than that fabricated from the 3Shape system ( p <0.05). Tukey's HSD multiple comparisons indicated that the zirconia restoration fabricated from either CS3500 or Trios-3 demonstrated a significantly larger marginal gap than the conventional cast metal restoration ( p <0.05). Full-arch zirconia restoration fabricated from the Trios-3 illustrated better marginal fits than that from the CS3500, although, both were slightly less accurate than the conventional cast restoration. However, the marginal discrepancies of restoration produced by both CAD-CAM systems were within the clinically acceptable range and satisfactorily precise to be suggested for construction full-arch zirconia restoration.

  1. Comparative study of flexural strength test methods on CAD/CAM Y-TZP dental ceramics

    PubMed Central

    Xu, Yongxiang; Han, Jianmin; Lin, Hong; An, Linan

    2015-01-01

    Clinically, fractures are the main cause of computer-aided design and computer-aided manufacturing (CAD/CAM) 3 mol%-yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) all-ceramic dental restorations failure because of repetitive occlusal loading. The goal of this work is to study the effect of test methods and specimen’s size on the flexural strength of five ceramic products. Both bi-axial flexure test (BI) and uni-axial flexure tests (UNI), including three-point flexure test (3PF) and four-point flexure test (4PF), are used in this study. For all five products, the flexural strength is as follows: BI > 3PF > 4PF. Furthermore, specimens with smaller size (3PF-s) have higher values than the bigger ones (3PF). The difference between BI and UNI resulted from the edge flaws in ceramic specimens. The relationship between different UNI (including 3PF-s, 3PF and 4PF) can be explained according to Weibull statistical fracture theory. BI is recommended to evaluate the flexural strength of CAD/CAM Y-TZP dental ceramics. PMID:26816646

  2. Investigating the Impact of Using a CAD Simulation Tool on Students' Learning of Design Thinking

    NASA Astrophysics Data System (ADS)

    Taleyarkhan, Manaz; Dasgupta, Chandan; Garcia, John Mendoza; Magana, Alejandra J.

    2018-02-01

    Engineering design thinking is hard to teach and still harder to learn by novices primarily due to the undetermined nature of engineering problems that often results in multiple solutions. In this paper, we investigate the effect of teaching engineering design thinking to freshmen students by using a computer-aided Design (CAD) simulation software. We present a framework for characterizing different levels of engineering design thinking displayed by students who interacted with the CAD simulation software in the context of a collaborative assignment. This framework describes the presence of four levels of engineering design thinking—beginning designer, adept beginning designer, informed designer, adept informed designer. We present the characteristics associated with each of these four levels as they pertain to four engineering design strategies that students pursued in this study—understanding the design challenge, building knowledge, weighing options and making tradeoffs, and reflecting on the process. Students demonstrated significant improvements in two strategies—understanding the design challenge and building knowledge. We discuss the affordances of the CAD simulation tool along with the learning environment that potentially helped students move towards Adept informed designers while pursuing these design strategies.

  3. Comparison of digital intraoral scanners by single-image capture system and full-color movie system.

    PubMed

    Yamamoto, Meguru; Kataoka, Yu; Manabe, Atsufumi

    2017-01-01

    The use of dental computer-aided design/computer-aided manufacturing (CAD/CAM) restoration is rapidly increasing. This study was performed to evaluate the marginal and internal cement thickness and the adhesive gap of internal cavities comprising CAD/CAM materials using two digital impression acquisition methods and micro-computed tomography. Images obtained by a single-image acquisition system (Bluecam Ver. 4.0) and a full-color video acquisition system (Omnicam Ver. 4.2) were divided into the BL and OM groups, respectively. Silicone impressions were prepared from an ISO-standard metal mold, and CEREC Stone BC and New Fuji Rock IMP were used to create working models (n=20) in the BL and OM groups (n=10 per group), respectively. Individual inlays were designed in a conventional manner using designated software, and all restorations were prepared using CEREC inLab MC XL. These were assembled with the corresponding working models used for measurement, and the level of fit was examined by three-dimensional analysis based on micro-computed tomography. Significant differences in the marginal and internal cement thickness and adhesive gap spacing were found between the OM and BL groups. The full-color movie capture system appears to be a more optimal restoration system than the single-image capture system.

  4. Accuracy of different types of computer-aided design/computer-aided manufacturing surgical guides for dental implant placement

    PubMed Central

    Geng, Wei; Liu, Changying; Su, Yucheng; Li, Jun; Zhou, Yanmin

    2015-01-01

    Purpose: To evaluate the clinical outcomes of implants placed using different types of computer-aided design/computer-aided manufacturing (CAD/CAM) surgical guides, including partially guided and totally guided templates, and determine the accuracy of these guides Materials and methods: In total, 111 implants were placed in 24 patients using CAD/CAM surgical guides. After implant insertion, the positions and angulations of the placed implants relative to those of the planned ones were determined using special software that matched pre- and postoperative computed tomography (CT) images, and deviations were calculated and compared between the different guides and templates. Results: The mean angular deviations were 1.72 ± 1.67 and 2.71 ± 2.58, the mean deviations in position at the neck were 0.27 ± 0.24 and 0.69 ± 0.66 mm, the mean deviations in position at the apex were 0.37 ± 0.35 and 0.94 ± 0.75 mm, and the mean depth deviations were 0.32 ± 0.32 and 0.51 ± 0.48 mm with tooth- and mucosa-supported stereolithographic guides, respectively (P < .05 for all). The mean distance deviations when partially guided (29 implants) and totally guided templates (30 implants) were used were 0.54 ± 0.50 mm and 0.89 ± 0.78 mm, respectively, at the neck and 1.10 ± 0.85 mm and 0.81 ± 0.64 mm, respectively, at the apex, with corresponding mean angular deviations of 2.56 ± 2.23° and 2.90 ± 3.0° (P > .05 for all). Conclusions: Tooth-supported surgical guides may be more accurate than mucosa-supported guides, while both partially and totally guided templates can simplify surgery and aid in optimal implant placement. PMID:26309497

  5. Quality assurance and training procedures for computer-aided detection and diagnosis systems in clinical usea)

    PubMed Central

    Huo, Zhimin; Summers, Ronald M.; Paquerault, Sophie; Lo, Joseph; Hoffmeister, Jeffrey; Armato, Samuel G.; Freedman, Matthew T.; Lin, Jesse; Ben Lo, Shih-Chung; Petrick, Nicholas; Sahiner, Berkman; Fryd, David; Yoshida, Hiroyuki; Chan, Heang-Ping

    2013-01-01

    Computer-aided detection/diagnosis (CAD) is increasingly used for decision support by clinicians for detection and interpretation of diseases. However, there are no quality assurance (QA) requirements for CAD in clinical use at present. QA of CAD is important so that end users can be made aware of changes in CAD performance both due to intentional or unintentional causes. In addition, end-user training is critical to prevent improper use of CAD, which could potentially result in lower overall clinical performance. Research on QA of CAD and user training are limited to date. The purpose of this paper is to bring attention to these issues, inform the readers of the opinions of the members of the American Association of Physicists in Medicine (AAPM) CAD subcommittee, and thus stimulate further discussion in the CAD community on these topics. The recommendations in this paper are intended to be work items for AAPM task groups that will be formed to address QA and user training issues on CAD in the future. The work items may serve as a framework for the discussion and eventual design of detailed QA and training procedures for physicists and users of CAD. Some of the recommendations are considered by the subcommittee to be reasonably easy and practical and can be implemented immediately by the end users; others are considered to be “best practice” approaches, which may require significant effort, additional tools, and proper training to implement. The eventual standardization of the requirements of QA procedures for CAD will have to be determined through consensus from members of the CAD community, and user training may require support of professional societies. It is expected that high-quality CAD and proper use of CAD could allow these systems to achieve their true potential, thus benefiting both the patients and the clinicians, and may bring about more widespread clinical use of CAD for many other diseases and applications. It is hoped that the awareness of the need for appropriate CAD QA and user training will stimulate new ideas and approaches for implementing such procedures efficiently and effectively as well as funding opportunities to fulfill such critical efforts. PMID:23822459

  6. Computer aided radiation analysis for manned spacecraft

    NASA Technical Reports Server (NTRS)

    Appleby, Matthew H.; Griffin, Brand N.; Tanner, Ernest R., II; Pogue, William R.; Golightly, Michael J.

    1991-01-01

    In order to assist in the design of radiation shielding an analytical tool is presented that can be employed in combination with CAD facilities and NASA transport codes. The nature of radiation in space is described, and the operational requirements for protection are listed as background information for the use of the technique. The method is based on the Boeing radiation exposure model (BREM) for combining NASA radiation transport codes and CAD facilities, and the output is given as contour maps of the radiation-shield distribution so that dangerous areas can be identified. Computational models are used to solve the 1D Boltzmann transport equation and determine the shielding needs for the worst-case scenario. BREM can be employed directly with the radiation computations to assess radiation protection during all phases of design which saves time and ultimately spacecraft weight.

  7. An Analysis of Item Identification for Additive Manufacturing (3-D Printing) Within the Naval Supply Chain

    DTIC Science & Technology

    2014-12-01

    manufacturing BPA blanket purchase agreement BMW Bavarian Motor Works CAD computer-aided design CASREP casualty report CDSA Combat Direction...agreements ( BPA ), and through existing indefinite delivery and indefinite quantity (IDIQ) contracts. These types of procurement methods have less visibility

  8. Clinical experience with a computer-aided diagnosis system for automatic detection of pulmonary nodules at spiral CT of the chest

    NASA Astrophysics Data System (ADS)

    Wormanns, Dag; Fiebich, Martin; Saidi, Mustafa; Diederich, Stefan; Heindel, Walter

    2001-05-01

    The purpose of the study was to evaluate a computer aided diagnosis (CAD) workstation with automatic detection of pulmonary nodules at low-dose spiral CT in a clinical setting for early detection of lung cancer. Two radiologists in consensus reported 88 consecutive spiral CT examinations. All examinations were reviewed using a UNIX-based CAD workstation with a self-developed algorithm for automatic detection of pulmonary nodules. The algorithm was designed to detect nodules with at least 5 mm diameter. The results of automatic nodule detection were compared to the consensus reporting of two radiologists as gold standard. Additional CAD findings were regarded as nodules initially missed by the radiologists or as false positive results. A total of 153 nodules were detected with all modalities (diameter: 85 nodules <5mm, 63 nodules 5-9 mm, 5 nodules >= 10 mm). Reasons for failure of automatic nodule detection were assessed. Sensitivity of radiologists for nodules >=5 mm was 85%, sensitivity of CAD was 38%. For nodules >=5 mm without pleural contact sensitivity was 84% for radiologists at 45% for CAD. CAD detected 15 (10%) nodules not mentioned in the radiologist's report but representing real nodules, among them 10 (15%) nodules with a diameter $GREW5 mm. Reasons for nodules missed by CAD include: exclusion because of morphological features during region analysis (33%), nodule density below the detection threshold (26%), pleural contact (33%), segmentation errors (5%) and other reasons (2%). CAD improves detection of pulmonary nodules at spiral CT significantly and is a valuable second opinion in a clinical setting for lung cancer screening. Optimization of region analysis and an appropriate density threshold have a potential for further improvement of automatic nodule detection.

  9. Different CAD/CAM-processing routes for zirconia restorations: influence on fitting accuracy.

    PubMed

    Kohorst, Philipp; Junghanns, Janet; Dittmer, Marc P; Borchers, Lothar; Stiesch, Meike

    2011-08-01

    The aim of the present in vitro study was to evaluate the influence of different processing routes on the fitting accuracy of four-unit zirconia fixed dental prostheses (FDPs) fabricated by computer-aided design/computer-aided manufacturing (CAD/CAM). Three groups of zirconia frameworks with ten specimens each were fabricated. Frameworks of one group (CerconCAM) were produced by means of a laboratory CAM-only system. The other frameworks were made with different CAD/CAM systems; on the one hand by in-laboratory production (CerconCAD/CAM) and on the other hand by centralized production in a milling center (Compartis) after forwarding geometrical data. Frameworks were then veneered with the recommended ceramics, and marginal accuracy was determined using a replica technique. Horizontal marginal discrepancy, vertical marginal discrepancy, absolute marginal discrepancy, and marginal gap were evaluated. Statistical analyses were performed by one-way analysis of variance (ANOVA), with the level of significance chosen at 0.05. Mean horizontal discrepancies ranged between 22 μm (CerconCAM) and 58 μm (Compartis), vertical discrepancies ranged between 63 μm (CerconCAD/CAM) and 162 μm (CerconCAM), and absolute marginal discrepancies ranged between 94 μm (CerconCAD/CAM) and 181 μm (CerconCAM). The marginal gap varied between 72 μm (CerconCAD/CAM) and 112 μm (CerconCAM, Compartis). Statistical analysis revealed that, with all measurements, the marginal accuracy of the zirconia FDPs was significantly influenced by the processing route used (p < 0.05). Within the limitations of this study, all restorations showed a clinically acceptable marginal accuracy; however, the results suggest that the CAD/CAM systems are more precise than the CAM-only system for the manufacture of four-unit FDPs.

  10. Marginal fit of all-ceramic crowns fabricated using two extraoral CAD/CAM systems in comparison with the conventional technique.

    PubMed

    Alqahtani, Fawaz

    2017-01-01

    The purpose of this study was to determine the effect of two extraoral computer-aided design (CAD) and computer-aided manufacturing (CAM) systems, in comparison with conventional techniques, on the marginal fit of monolithic CAD/CAM lithium disilicate ceramic crowns. This is an in vitro interventional study. The study was carried out at the Department of Prosthodontics, School of Dentistry, Prince Sattam Bin Abdul-Aziz University, Saudi Arabia, from December 2015 to April 2016. A marginal gap of 60 lithium disilicate crowns was evaluated by scanning electron microscopy. In total, 20 pressable lithium disilicate (IPS e.max Press [Ivoclar Vivadent]) ceramic crowns were fabricated using the conventional lost-wax technique as a control group. The experimental all-ceramic crowns were produced based on a scan stone model and milled using two extraoral CAD/CAM systems: the Cerec group was fabricated using the Cerec CAD/CAM system, and the Trios group was fabricated using Trios CAD and milled using Wieland Zenotec CAM. One-way analysis of variance (ANOVA) and the Scheffe post hoc test were used for statistical comparison of the groups (α=0.05). The mean (±standard deviation) of the marginal gap of each group was as follows: the Control group was 91.15 (±15.35) µm, the Cerec group was 111.07 (±6.33) µm, and the Trios group was 60.17 (±11.09) µm. One-way ANOVA and the Scheffe post hoc test showed a statistically significant difference in the marginal gap between all groups. It can be concluded from the current study that all-ceramic crowns, fabricated using the CAD/CAM system, show a marginal accuracy that is acceptable in clinical environments. The Trios CAD group displayed the smallest marginal gap.

  11. Effect of denture cleaning on abrasion resistance and surface topography of polymerized CAD CAM acrylic resin denture base

    PubMed Central

    Shinawi, Lana Ahmed

    2017-01-01

    Background The application of computer-aided design computer-aided manufacturing (CAD CAM) technology in the fabrication of complete dentures, offers numerous advantages as it provides optimum fit and eliminates polymerization shrinkage of the acrylic base. Additionally, the porosity and surface roughness of CAD CAM resins is less compared to conventionally processed resins which leads to a decrease in the adhesion of bacteria on the denture base, which is associated with many conditions including halitosis and aspiration pneumonia in elderly denture wearers. Aim To evaluate the influence of tooth brushing with dentifrices on CAD CAM resin blocks in terms of abrasion resistance, surface roughness and scanning electron photomicrography. Methods This experimental study was carried out at the Faculty of Dentistry of King Abdulaziz University during 2016. A total of 40 rectangular shaped polymerized CAD CAM resin samples were subjected to 40.000 and 60.000 brushing strokes under a 200-gram vertical load simulating three years of tooth brushing strokes using commercially available denture cleaning dentifrice. Data were analyzed by SPSS version 20, using descriptive statistics and ANOVA. Results ANOVA test revealed a statistical significant weight loss of CAD CAM acrylic resin denture base specimens following 40.000 and 60.000 brushing strokes as well as a statistical significant change (p=0.0.5) in the surface roughness following brushing. The CAD CAM resin samples SEM baseline imaging revealed a relatively smooth homogenous surface, but following 40,000 and 60,000 brushing strokes, imaging displayed the presence of small scratches on the surface. Conclusion CAD CAM resin displayed a homogenous surface initially with low surface roughness that was significantly affected following simulating three years of manual brushing, but despite the significant weight loss, the findings are within the clinically acceptable limits. PMID:28713496

  12. Effect of denture cleaning on abrasion resistance and surface topography of polymerized CAD CAM acrylic resin denture base.

    PubMed

    Shinawi, Lana Ahmed

    2017-05-01

    The application of computer-aided design computer-aided manufacturing (CAD CAM) technology in the fabrication of complete dentures, offers numerous advantages as it provides optimum fit and eliminates polymerization shrinkage of the acrylic base. Additionally, the porosity and surface roughness of CAD CAM resins is less compared to conventionally processed resins which leads to a decrease in the adhesion of bacteria on the denture base, which is associated with many conditions including halitosis and aspiration pneumonia in elderly denture wearers. To evaluate the influence of tooth brushing with dentifrices on CAD CAM resin blocks in terms of abrasion resistance, surface roughness and scanning electron photomicrography. This experimental study was carried out at the Faculty of Dentistry of King Abdulaziz University during 2016. A total of 40 rectangular shaped polymerized CAD CAM resin samples were subjected to 40.000 and 60.000 brushing strokes under a 200-gram vertical load simulating three years of tooth brushing strokes using commercially available denture cleaning dentifrice. Data were analyzed by SPSS version 20, using descriptive statistics and ANOVA. ANOVA test revealed a statistical significant weight loss of CAD CAM acrylic resin denture base specimens following 40.000 and 60.000 brushing strokes as well as a statistical significant change (p=0.0.5) in the surface roughness following brushing. The CAD CAM resin samples SEM baseline imaging revealed a relatively smooth homogenous surface, but following 40,000 and 60,000 brushing strokes, imaging displayed the presence of small scratches on the surface. CAD CAM resin displayed a homogenous surface initially with low surface roughness that was significantly affected following simulating three years of manual brushing, but despite the significant weight loss, the findings are within the clinically acceptable limits.

  13. Particle tracking acceleration via signed distance fields in direct-accelerated geometry Monte Carlo

    DOE PAGES

    Shriwise, Patrick C.; Davis, Andrew; Jacobson, Lucas J.; ...

    2017-08-26

    Computer-aided design (CAD)-based Monte Carlo radiation transport is of value to the nuclear engineering community for its ability to conduct transport on high-fidelity models of nuclear systems, but it is more computationally expensive than native geometry representations. This work describes the adaptation of a rendering data structure, the signed distance field, as a geometric query tool for accelerating CAD-based transport in the direct-accelerated geometry Monte Carlo toolkit. Demonstrations of its effectiveness are shown for several problems. The beginnings of a predictive model for the data structure's utilization based on various problem parameters is also introduced.

  14. TRAD or CAD? A Comparison.

    ERIC Educational Resources Information Center

    Resetarits, Paul J.

    1989-01-01

    Studies whether traditional drafting equipment (TRAD) or computer aided drafting equipment (CAD) is more effective. Proposes that students using only CAD can learn principles of drafting as well as students using only TRAD. Reports no significant difference either on achievement or attitude. (MVL)

  15. Ergonomics Perspective in Agricultural Research: A User-Centred Approach Using CAD and Digital Human Modeling (DHM) Technologies

    NASA Astrophysics Data System (ADS)

    Patel, Thaneswer; Sanjog, J.; Karmakar, Sougata

    2016-09-01

    Computer-aided Design (CAD) and Digital Human Modeling (DHM) (specialized CAD software for virtual human representation) technologies endow unique opportunities to incorporate human factors pro-actively in design development. Challenges of enhancing agricultural productivity through improvement of agricultural tools/machineries and better human-machine compatibility can be ensured by adoption of these modern technologies. Objectives of present work are to provide the detailed scenario of CAD and DHM applications in agricultural sector; and finding out means for wide adoption of these technologies for design and development of cost-effective, user-friendly, efficient and safe agricultural tools/equipment and operator's workplace. Extensive literature review has been conducted for systematic segregation and representation of available information towards drawing inferences. Although applications of various CAD software have momentum in agricultural research particularly for design and manufacturing of agricultural equipment/machinery, use of DHM is still at its infancy in this sector. Current review discusses about reasons of less adoption of these technologies in agricultural sector and steps to be taken for their wide adoption. It also suggests possible future research directions to come up with better ergonomic design strategies for improvement of agricultural equipment/machines and workstations through application of CAD and DHM.

  16. True Concurrent Thermal Engineering Integrating CAD Model Building with Finite Element and Finite Difference Methods

    NASA Technical Reports Server (NTRS)

    Panczak, Tim; Ring, Steve; Welch, Mark

    1999-01-01

    Thermal engineering has long been left out of the concurrent engineering environment dominated by CAD (computer aided design) and FEM (finite element method) software. Current tools attempt to force the thermal design process into an environment primarily created to support structural analysis, which results in inappropriate thermal models. As a result, many thermal engineers either build models "by hand" or use geometric user interfaces that are separate from and have little useful connection, if any, to CAD and FEM systems. This paper describes the development of a new thermal design environment called the Thermal Desktop. This system, while fully integrated into a neutral, low cost CAD system, and which utilizes both FEM and FD methods, does not compromise the needs of the thermal engineer. Rather, the features needed for concurrent thermal analysis are specifically addressed by combining traditional parametric surface based radiation and FD based conduction modeling with CAD and FEM methods. The use of flexible and familiar temperature solvers such as SINDA/FLUINT (Systems Improved Numerical Differencing Analyzer/Fluid Integrator) is retained.

  17. Effect of cement space on the marginal fit of CAD-CAM-fabricated monolithic zirconia crowns.

    PubMed

    Kale, Ediz; Seker, Emre; Yilmaz, Burak; Özcelik, Tuncer Burak

    2016-12-01

    Monolithic zirconia crowns fabricated with computer-aided design and computer-aided manufacturing (CAD-CAM) have recently become a common practice for the restoration of posterior teeth. The marginal fit of monolithic zirconia crowns may be affected by different cement space parameters set in the CAD software. Information is scarce regarding the effect of cement space on the marginal fit of monolithic zirconia crowns fabricated with CAD-CAM technology. The purpose of this in vitro study was to evaluate the effect of cement space on the marginal fit of CAD-CAM-fabricated monolithic zirconia crowns before cementation. Fifteen right maxillary first molar typodont teeth with standardized anatomic preparations for complete-coverage ceramic crowns were scanned with a 3-dimensional laboratory scanner. Crowns were designed 3-dimensionally using software and then milled from presintered monolithic zirconia blocks in a computer numerical control dental milling machine. The cement space was set at 25 μm around the margins for all groups, and additional cement space starting 1 mm above the finish lines of the teeth was set at 30 μm for group 25-30, 40 μm for group 25-40, and 50 μm for group 25-50 in the CAD software. A total of 120 images (3 groups, 5 crowns per group, 8 sites per crown) were measured for vertical marginal discrepancy under a stereoscopic zoom microscope and the data were statistically analyzed with 1-way analysis of variance, followed by the Tukey honestly significant difference test (α=.05). The results showed that different cement space values had statistically significant effect on the mean vertical marginal discrepancy value of tested crowns (P<.001). The mean marginal discrepancy was 85 μm for group 25-30, 68 μm for group 25-40, and 53 μm for group 25-50. Within the limitations of this in vitro study, it was concluded that the cement space had a significant effect on the marginal fit of CAD-CAM-fabricated monolithic zirconia crowns. The marginal fit improved as the cement space decreased. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  18. Fabricating a tooth- and implant-supported maxillary obturator for a patient after maxillectomy with computer-guided surgery and CAD/CAM technology: A clinical report.

    PubMed

    Noh, Kwantae; Pae, Ahran; Lee, Jung-Woo; Kwon, Yong-Dae

    2016-05-01

    An obturator prosthesis with insufficient retention and support may be improved with implant placement. However, implant surgery in patients after maxillary tumor resection can be complicated because of limited visibility and anatomic complexity. Therefore, computer-guided surgery can be advantageous even for experienced surgeons. In this clinical report, the use of computer-guided surgery is described for implant placement using a bone-supported surgical template for a patient with maxillary defects. The prosthetic procedure was facilitated and simplified by using computer-aided design/computer-aided manufacture (CAD/CAM) technology. Oral function and phonetics were restored using a tooth- and implant-supported obturator prosthesis. No clinical symptoms and no radiographic signs of significant bone loss around the implants were found at a 3-year follow-up. The treatment approach presented here can be a viable option for patients with insufficient remaining zygomatic bone after a hemimaxillectomy. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  19. Marginal adaptation and CAD-CAM technology: A systematic review of restorative material and fabrication techniques.

    PubMed

    Papadiochou, Sofia; Pissiotis, Argirios L

    2018-04-01

    The comparative assessment of computer-aided design and computer-aided manufacturing (CAD-CAM) technology and other fabrication techniques pertaining to marginal adaptation should be documented. Limited evidence exists on the effect of restorative material on the performance of a CAD-CAM system relative to marginal adaptation. The purpose of this systematic review was to investigate whether the marginal adaptation of CAD-CAM single crowns, fixed dental prostheses, and implant-retained fixed dental prostheses or their infrastructures differs from that obtained by other fabrication techniques using a similar restorative material and whether it depends on the type of restorative material. An electronic search of English-language literature published between January 1, 2000, and June 30, 2016, was conducted of the Medline/PubMed database. Of the 55 included comparative studies, 28 compared CAD-CAM technology with conventional fabrication techniques, 12 contrasted CAD-CAM technology and copy milling, 4 compared CAD-CAM milling with direct metal laser sintering (DMLS), and 22 investigated the performance of a CAD-CAM system regarding marginal adaptation in restorations/infrastructures produced with different restorative materials. Most of the CAD-CAM restorations/infrastructures were within the clinically acceptable marginal discrepancy (MD) range. The performance of a CAD-CAM system relative to marginal adaptation is influenced by the restorative material. Compared with CAD-CAM, most of the heat-pressed lithium disilicate crowns displayed equal or smaller MD values. Slip-casting crowns exhibited similar or better marginal accuracy than those fabricated with CAD-CAM. Cobalt-chromium and titanium implant infrastructures produced using a CAD-CAM system elicited smaller MD values than zirconia. The majority of cobalt-chromium restorations/infrastructures produced by DMLS displayed better marginal accuracy than those fabricated with the casting technique. Compared with copy milling, the majority of zirconia restorations/infrastructures produced by CAD-CAM milling exhibited better marginal adaptation. No clear conclusions can be drawn about the superiority of CAD-CAM milling over the casting technique and DMLS regarding marginal adaptation. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  20. Technical report: precisely fitting bars on implants in five steps-a CAD/CAM concept for the edentulous mandible.

    PubMed

    Beuer, Florian; Schweiger, Josef; Huber, Martin; Engels, Jörg; Stimmelmayr, Michael

    2014-06-01

    Various treatment concepts have been presented for the edentulous mandible. Manufacturing tension-free and precisely fitting bars on dental implants was previously a great challenge in prosthetic dentistry and required great effort. Modern computer aided design/computer aided manufacturing technology in combination with some clinical modifications of the established workflow enables the clinician to achieve precise results in a very efficient way. The innovative five-step concept is presented in a clinical case. © 2014 by the American College of Prosthodontists.

  1. A digital approach to fabricating an abutment replica to control cement volume in a cement-retained implant prosthesis.

    PubMed

    Lee, Ju-Hyoung; Park, In-Sook; Sohn, Dong-Seok

    2016-07-01

    If a cement-retained implant prosthesis is placed on an abutment, excess cement should be minimized or removed to prevent periimplant inflammation. Various methods for fabricating an abutment replica have been introduced to maintain tissue health and reduce clean-up time. The purpose of this article is to present an alternative technique for fabricating an abutment replica with computer-aided design/computer-aided manufacturing (CAD/CAM) technology. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  2. In vitro evaluation of marginal discrepancy of monolithic zirconia restorations fabricated with different CAD-CAM systems.

    PubMed

    Hamza, Tamer A; Sherif, Rana M

    2017-06-01

    Dental laboratories use different computer-aided design and computer-aided manufacturing (CAD-CAM) systems to fabricate fixed prostheses; however, limited evidence is available concerning which system provides the best marginal discrepancy. The purpose of this in vitro study was to evaluate the marginal fit of 5 different monolithic zirconia restorations milled with different CAD-CAM systems. Thirty monolithic zirconia crowns were fabricated on a custom-designed stainless steel die and were divided into 5 groups according to the type of monolithic zirconia crown and the CAD-CAM system used: group TZ, milled with an MCXL milling machine; group CZ, translucent zirconia milled with a motion milling machine; group ZZ, zirconia milled with a dental milling unit; group PZ, translucent zirconia milled with a zirconia milling unit; and group BZ, solid zirconia milled using an S1 VHF milling machine. The marginal fit was measured with a binocular microscope at an original magnification of ×100. The results were tabulated and statistically analyzed with 1-way ANOVA and post hoc surface range test, and pairwise multiple comparisons were made using Bonferroni correction (α=.05). The type of CAD-CAM used affected the marginal fit of the monolithic restoration. The mean (±SD) highest marginal discrepancy was recorded in group TZI at 39.3 ±2.3 μm, while the least mean marginal discrepancy was recorded in group IZ (22.8 ±8.9 μm). The Bonferroni post hoc test showed that group TZI was significantly different from all other groups tested (P<.05). Within the limitation of this in vitro study, all tested CAD-CAM systems produced monolithic zirconia restorations with clinically acceptable marginal discrepancies; however, the CAD-CAM system with the 5-axis milling unit produced the best marginal fit. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  3. Using Additive Manufacturing to Mitigate the Risks of Limited Key Ship Components of the Zumwalt-Class Destroyer

    DTIC Science & Technology

    2016-12-01

    4 3. Design and Production Maturity...issues (PEO Ships, 2016). 6 3. Design and Production Maturity Despite the fact that the Navy accepted the first ship, USS Zumwalt (DDG 1000...The modern day of AM is a process that uses Computer-Aided Design (CAD) software to create three-dimensional (3D) products by adding one layer on top

  4. Jack Human Modelling Tool: A Review

    DTIC Science & Technology

    2010-01-01

    live” test subjects. In the early 1960s computer aided design (CAD) software became available, and aerospace and automotive manufacturers saw the... design would be assessed using anthropometric mannequins (such as the Society of Automotive Engineers J826B H-Point mannequin) or “live” test subjects...TR-2364 ABSTRACT When evaluating the design of a workstation human factors practitioners have traditionally used a number of different

  5. 3D-WOVEN FIBER-REINFORCED COMPOSITE FOR CAD/CAM DENTAL APPLICATION

    PubMed Central

    Petersen, Richard; Liu, Perng-Ru

    2016-01-01

    Three-dimensional (3D)-woven noncrimp fiber-reinforced composite (FRC) was tested for mechanical properties in the two principal directions of the main XY plane and compared to different Computer-Aided-Design/Computer-Aided-Machining (CAD/CAM) Dental Materials. The Dental Materials included ceramic with Vitablock Mark II®, ProCAD®, InCeram® Spinel, InCeram® Alumina and InCeram® Zirconia in addition to a resin-based 3M Corp. Paradigm® particulate-filled composite. Alternate material controls included Coors 300 Alumina Ceramic and a tungsten carbide 22% cobalt cermet. The 3D-woven FRC was vacuum assisted resin transfer molding processed as a one-depth-thickness ~19-mm preform with a vinyl-ester resin and cut into blocks similar to the commercial CAD/CAM Dental Materials. Mechanical test samples prepared for a flexural three-point span length of 10.0 mm were sectioned for minimum-depth cuts to compare machinability and fracture resistance between groups. 3D-woven FRC improved mechanical properties with significant statistical differences over all CAD/CAM Dental Materials and Coors Alumina Ceramic for flexural strength (p<0.001), resilience (p<0.05), work of fracture (p<0.001), strain energy release (p<0.05), critical stress intensity factor (p<0.001) and strain (p<0.001). PMID:27642198

  6. Effect of the Crystallization Process on the Marginal and Internal Gaps of Lithium Disilicate CAD/CAM Crowns

    PubMed Central

    Kim, Jae-Hong; Oh, Seunghan; Uhm, Soo-Hyuk

    2016-01-01

    The aim of this study is to quantify the effect of the crystallization process on lithium disilicate ceramic crowns fabricated using a computer-aided design/computer-aided manufacturing (CAD/CAM) system and to determine whether the effect of crystallization is clinically acceptable by comparing values of fit before and after the crystallization process. The mandibular right first molar was selected as the abutment for the experiments. Fifteen working models were prepared. Lithium disilicate crowns appropriate for each abutment were prepared using a commercial CAD/CAM system. Gaps in the marginal area and 4 internal areas of each crown were measured twice—before and after crystallization—using the silicone replica technique. The mean values of fit before and after crystallization were analyzed using a paired t-test to examine whether the conversion that occurred during crystallization affected marginal and internal gaps (α = 0.05). Gaps increased in the marginal area and decreased in the internal areas after crystallization. There were statistically significant differences in all of the investigated areas (P < 0.05). None of the values for marginal and internal fit of lithium disilicate CAD/CAM crowns after crystallization exceeded 120 μm, which is the clinically acceptable threshold. PMID:27123453

  7. 3D-WOVEN FIBER-REINFORCED COMPOSITE FOR CAD/CAM DENTAL APPLICATION.

    PubMed

    Petersen, Richard; Liu, Perng-Ru

    2016-05-01

    Three-dimensional (3D)-woven noncrimp fiber-reinforced composite (FRC) was tested for mechanical properties in the two principal directions of the main XY plane and compared to different Computer-Aided-Design/Computer-Aided-Machining (CAD/CAM) Dental Materials. The Dental Materials included ceramic with Vitablock Mark II®, ProCAD®, InCeram® Spinel, InCeram® Alumina and InCeram® Zirconia in addition to a resin-based 3M Corp. Paradigm® particulate-filled composite. Alternate material controls included Coors 300 Alumina Ceramic and a tungsten carbide 22% cobalt cermet. The 3D-woven FRC was vacuum assisted resin transfer molding processed as a one-depth-thickness ~19-mm preform with a vinyl-ester resin and cut into blocks similar to the commercial CAD/CAM Dental Materials. Mechanical test samples prepared for a flexural three-point span length of 10.0 mm were sectioned for minimum-depth cuts to compare machinability and fracture resistance between groups. 3D-woven FRC improved mechanical properties with significant statistical differences over all CAD/CAM Dental Materials and Coors Alumina Ceramic for flexural strength (p<0.001), resilience (p<0.05), work of fracture (p<0.001), strain energy release (p<0.05), critical stress intensity factor (p<0.001) and strain (p<0.001).

  8. Development Of A Numerical Tow Tank With Wave Generation To Supplement Experimental Efforts

    DTIC Science & Technology

    2017-12-01

    vehicles CAD computer aided design CFD computational fluid dynamics FVM finite volume method IO information operations ISR intelligence, surveillance, and...deliver a product that I am truly proud of. xv THIS PAGE INTENTIONALLY LEFT BLANK xvi CHAPTER 1: Introduction 1.1 Importance of Tow Tank Testing Modern...wedge installation. 1 In 2016, NPS student Ensign Ryan Tran adapted an existing vertical plunging wedge wave maker design used at the U.S. Naval

  9. Simplified treatment of severe dental erosion with ultrathin CAD-CAM composite occlusal veneers and anterior bilaminar veneers.

    PubMed

    Schlichting, Luís Henrique; Resende, Tayane Holz; Reis, Kátia Rodrigues; Magne, Pascal

    2016-10-01

    Restorative treatment for patients with dental erosion requires an analysis of the degree of structural damage. Patients affected by moderate to severe dental erosion are particularly challenging because complex occlusal reconstruction will be needed. Ultrathin bonded occlusal veneers represent a conservative alternative to traditional onlays and complete coverage crowns for the treatment of severe erosion. This article describes a complete mouth rehabilitation with ultrathin computer-aided design and computer-aided manufacturing (CAD-CAM) composite resin occlusal veneers in a patient with a severely eroded dentition. In the maxillary anterior teeth, the bilaminar approach was chosen with lingual composite resin veneers and labial porcelain veneers. The main benefit of this approach is the possibility of using additive adhesive techniques, allowing only strategic reduction of sound dental structure or no preparation. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  10. Virtual Reality and Cyberspace: From Science Fiction to Science Fact.

    ERIC Educational Resources Information Center

    Stone, Robert J.

    1991-01-01

    Traces the history of virtual reality (VR), or cyberspace, and describes some of the research and development efforts currently being carried out in the United Kingdom, Europe, and the United States. Applications of VR in interactive computer-aided design (CAD), the military, leisure activities, spaceflight, teleconferencing, and medicine are…

  11. Development of Processing Parameters for Organic Binders Using Selective Laser Sintering

    NASA Technical Reports Server (NTRS)

    Mobasher, Amir A.

    2003-01-01

    This document describes rapid prototyping, its relation to Computer Aided Design (CAD), and the application of these techniques to choosing parameters for Selective Laser Sintering (SLS). The document reviews the parameters selected by its author for his project, the SLS machine used, and its software.

  12. Computer aided analysis, simulation and optimisation of thermal sterilisation processes.

    PubMed

    Narayanan, C M; Banerjee, Arindam

    2013-04-01

    Although thermal sterilisation is a widely employed industrial process, little work is reported in the available literature including patents on the mathematical analysis and simulation of these processes. In the present work, software packages have been developed for computer aided optimum design of thermal sterilisation processes. Systems involving steam sparging, jacketed heating/cooling, helical coils submerged in agitated vessels and systems that employ external heat exchangers (double pipe, shell and tube and plate exchangers) have been considered. Both batch and continuous operations have been analysed and simulated. The dependence of del factor on system / operating parameters such as mass or volume of substrate to be sterilised per batch, speed of agitation, helix diameter, substrate to steam ratio, rate of substrate circulation through heat exchanger and that through holding tube have been analysed separately for each mode of sterilisation. Axial dispersion in the holding tube has also been adequately accounted for through an appropriately defined axial dispersion coefficient. The effect of exchanger characteristics/specifications on the system performance has also been analysed. The multiparameter computer aided design (CAD) software packages prepared are thus highly versatile in nature and they permit to make the most optimum choice of operating variables for the processes selected. The computed results have been compared with extensive data collected from a number of industries (distilleries, food processing and pharmaceutical industries) and pilot plants and satisfactory agreement has been observed between the two, thereby ascertaining the accuracy of the CAD softwares developed. No simplifying assumptions have been made during the analysis and the design of associated heating / cooling equipment has been performed utilising the most updated design correlations and computer softwares.

  13. Evaluation of MTANNs for eliminating false-positive with different computer aided pulmonary nodules detection software.

    PubMed

    Shi, Zhenghao; Ma, Jiejue; Feng, Yaning; He, Lifeng; Suzuki, Kenji

    2015-11-01

    MTANN (Massive Training Artificial Neural Network) is a promising tool, which applied to eliminate false-positive for thoracic CT in recent years. In order to evaluate whether this method is feasible to eliminate false-positive of different CAD schemes, especially, when it is applied to commercial CAD software, this paper evaluate the performance of the method for eliminating false-positives produced by three different versions of commercial CAD software for lung nodules detection in chest radiographs. Experimental results demonstrate that the approach is useful in reducing FPs for different computer aided lung nodules detection software in chest radiographs.

  14. Integration of a CAS/DGS as a CAD System in the Mathematics Curriculum for Architecture Students

    ERIC Educational Resources Information Center

    Falcon, R. M.

    2011-01-01

    Students of Architecture and Building Engineering Degrees work with Computer Aided Design systems daily in order to design and model architectonic constructions. Since this kind of software is based on the creation and transformation of geometrical objects, it seems to be a useful tool in Maths classes in order to capture the attention of the…

  15. Simple and Inexpensive 3D Printed Filter Fluorometer Designs: User-Friendly Instrument Models for Laboratory Learning and Outreach Activities

    ERIC Educational Resources Information Center

    Porter, Lon A., Jr.; Chapman, Cole A.; Alaniz, Jacob A.

    2017-01-01

    In this work, a versatile and user-friendly selection of stereolithography (STL) files and computer-aided design (CAD) models are shared to assist educators and students in the production of simple and inexpensive 3D printed filter fluorometer instruments. These devices are effective resources for supporting active learners in the exploration of…

  16. Two-body wear rate of CAD/CAM resin blocks and their enamel antagonists.

    PubMed

    Stawarczyk, Bogna; Özcan, Mutlu; Trottmann, Albert; Schmutz, Felix; Roos, Malgorzata; Hämmerle, Christoph

    2013-05-01

    Computer-aided design and computer-aided manufacturing (CAD/CAM) resins exhibit good mechanical properties and can be used as long-term restorations. The wear rate of such resins and their enamel antagonists is unknown. The purpose of this study was to test and compare the 2-body wear rate of CAD/CAM resin blocks. Wear specimens (N=42, n=6) were made from 5 CAD/CAM resins: ZENO PMMA (ZP), artBloc Temp (AT), Telio CAD (TC), Blanc High-class (HC), CAD-Temp (CT); 1 manually polymerized resin: Integral esthetic press (negative control group, IEP); and 1 glass-ceramic: VITA Mark II (positive control group, VM2). The specimens for the wear resistance were aged in a thermomechanical loading machine (49 N, 1.67 Hz, 5/50°C) with human enamel antagonists. The material loss of all specimens before, during, and after aging was evaluated with a 3DS profilometer. The measured material loss data of all tested groups were statistically evaluated with linear mixed model analysis (a=.05). Manually polymerized resin showed significantly higher material wear (P<.001) than all other tested groups. Glass-ceramic showed significantly lower wear values (P<.001) than CAD/CAM resins ZP, AT, HC, CT, and IES. CAD/CAM resin TC was not significantly different from the positive control group. Glass-ceramic showed the highest enamel wear values (P<.001) of all tested resins. No differences were found in the enamel wear among all resins. The glass-ceramic group showed damage in the form of cracks on the worn enamel surface in 50% of specimens. CAD/CAM resins showed lower wear rates than those conventionally polymerized. Only one CAD/CAM resin, TC, presented material wear values comparable with glass-ceramic. The tested glass-ceramic developed cracks in the enamel antagonist and showed the highest enamel wear values of all other tested groups. Copyright © 2013 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  17. Shape optimization and CAD

    NASA Technical Reports Server (NTRS)

    Rasmussen, John

    1990-01-01

    Structural optimization has attracted the attention since the days of Galileo. Olhoff and Taylor have produced an excellent overview of the classical research within this field. However, the interest in structural optimization has increased greatly during the last decade due to the advent of reliable general numerical analysis methods and the computer power necessary to use them efficiently. This has created the possibility of developing general numerical systems for shape optimization. Several authors, eg., Esping; Braibant & Fleury; Bennet & Botkin; Botkin, Yang, and Bennet; and Stanton have published practical and successful applications of general optimization systems. Ding and Homlein have produced extensive overviews of available systems. Furthermore, a number of commercial optimization systems based on well-established finite element codes have been introduced. Systems like ANSYS, IDEAS, OASIS, and NISAOPT are widely known examples. In parallel to this development, the technology of computer aided design (CAD) has gained a large influence on the design process of mechanical engineering. The CAD technology has already lived through a rapid development driven by the drastically growing capabilities of digital computers. However, the systems of today are still considered as being only the first generation of a long row of computer integrated manufacturing (CIM) systems. These systems to come will offer an integrated environment for design, analysis, and fabrication of products of almost any character. Thus, the CAD system could be regarded as simply a database for geometrical information equipped with a number of tools with the purpose of helping the user in the design process. Among these tools are facilities for structural analysis and optimization as well as present standard CAD features like drawing, modeling, and visualization tools. The state of the art of structural optimization is that a large amount of mathematical and mechanical techniques are available for the solution of single problems. By implementing collections of the available techniques into general software systems, operational environments for structural optimization have been created. The forthcoming years must bring solutions to the problem of integrating such systems into more general design environments. The result of this work should be CAD systems for rational design in which structural optimization is one important design tool among many others.

  18. Aeroelastic Deflection of NURBS Geometry

    NASA Technical Reports Server (NTRS)

    Samareh, Jamshid A.

    1998-01-01

    The purpose of this paper is to present an algorithm for using NonUniform Rational B-Spline (NURBS) representation in an aeroelastic loop. The algorithm is based on creating a least-squares NURBS surface representing the aeroelastic defection. The resulting NURBS surfaces are used to update either the original Computer- Aided Design (CAD) model, Computational Structural Mechanics (CSM) grid or the Computational Fluid Dynamics (CFD) grid. Results are presented for a generic High-Speed Civil Transport (HSCT).

  19. DeviceEditor visual biological CAD canvas

    PubMed Central

    2012-01-01

    Background Biological Computer Aided Design (bioCAD) assists the de novo design and selection of existing genetic components to achieve a desired biological activity, as part of an integrated design-build-test cycle. To meet the emerging needs of Synthetic Biology, bioCAD tools must address the increasing prevalence of combinatorial library design, design rule specification, and scar-less multi-part DNA assembly. Results We report the development and deployment of web-based bioCAD software, DeviceEditor, which provides a graphical design environment that mimics the intuitive visual whiteboard design process practiced in biological laboratories. The key innovations of DeviceEditor include visual combinatorial library design, direct integration with scar-less multi-part DNA assembly design automation, and a graphical user interface for the creation and modification of design specification rules. We demonstrate how biological designs are rendered on the DeviceEditor canvas, and we present effective visualizations of genetic component ordering and combinatorial variations within complex designs. Conclusions DeviceEditor liberates researchers from DNA base-pair manipulation, and enables users to create successful prototypes using standardized, functional, and visual abstractions. Open and documented software interfaces support further integration of DeviceEditor with other bioCAD tools and software platforms. DeviceEditor saves researcher time and institutional resources through correct-by-construction design, the automation of tedious tasks, design reuse, and the minimization of DNA assembly costs. PMID:22373390

  20. Computed-aided diagnosis (CAD) in the detection of breast cancer.

    PubMed

    Dromain, C; Boyer, B; Ferré, R; Canale, S; Delaloge, S; Balleyguier, C

    2013-03-01

    Computer-aided detection (CAD) systems have been developed for interpretation to improve mammographic detection of breast cancer at screening by reducing the number of false-negative interpretation that can be caused by subtle findings, radiologist distraction and complex architecture. They use a digitized mammographic image that can be obtained from both screen-film mammography and full field digital mammography. Its performance in breast cancer detection is dependent on the performance of the CAD itself, the population to which it is applied and the radiologists who use it. There is a clear benefit to the use of CAD in less experienced radiologist and in detecting breast carcinomas presenting as microcalcifications. This review gives a detailed description CAD systems used in mammography and their performance in assistance of reading in screening mammography and as an alternative to double reading. Other CAD systems developed for MRI and ultrasound are also presented and discussed. Copyright © 2012. Published by Elsevier Ireland Ltd.

  1. A CAD (Classroom Assessment Design) of a Computer Programming Course

    ERIC Educational Resources Information Center

    Hawi, Nazir S.

    2012-01-01

    This paper presents a CAD (classroom assessment design) of an entry-level undergraduate computer programming course "Computer Programming I". CAD has been the product of a long experience in teaching computer programming courses including teaching "Computer Programming I" 22 times. Each semester, CAD is evaluated and modified…

  2. Automated extraction of knowledge for model-based diagnostics

    NASA Technical Reports Server (NTRS)

    Gonzalez, Avelino J.; Myler, Harley R.; Towhidnejad, Massood; Mckenzie, Frederic D.; Kladke, Robin R.

    1990-01-01

    The concept of accessing computer aided design (CAD) design databases and extracting a process model automatically is investigated as a possible source for the generation of knowledge bases for model-based reasoning systems. The resulting system, referred to as automated knowledge generation (AKG), uses an object-oriented programming structure and constraint techniques as well as internal database of component descriptions to generate a frame-based structure that describes the model. The procedure has been designed to be general enough to be easily coupled to CAD systems that feature a database capable of providing label and connectivity data from the drawn system. The AKG system is capable of defining knowledge bases in formats required by various model-based reasoning tools.

  3. Executing CLIPS expert systems in a distributed environment

    NASA Technical Reports Server (NTRS)

    Taylor, James; Myers, Leonard

    1990-01-01

    This paper describes a framework for running cooperating agents in a distributed environment to support the Intelligent Computer Aided Design System (ICADS), a project in progress at the CAD Research Unit of the Design Institute at the California Polytechnic State University. Currently, the systems aids an architectural designer in creating a floor plan that satisfies some general architectural constraints and project specific requirements. At the core of ICADS is the Blackboard Control System. Connected to the blackboard are any number of domain experts called Intelligent Design Tools (IDT). The Blackboard Control System monitors the evolving design as it is being drawn and helps resolve conflicts from the domain experts. The user serves as a partner in this system by manipulating the floor plan in the CAD system and validating recommendations made by the domain experts. The primary components of the Blackboard Control System are two expert systems executed by a modified CLIPS shell. The first is the Message Handler. The second is the Conflict Resolver. The Conflict Resolver synthesizes the suggestions made by the domain experts, which can be either CLIPS expert systems, or compiled C programs. In DEMO1, the current ICADS prototype, the CLIPS domain expert systems are Acoustics, Lighting, Structural, and Thermal; the compiled C domain experts are the CAD system and the User Interface.

  4. Pitfalls and solutions in virtual design of nasoalveolar molding plates by using CAD/CAM technology--A preliminary clinical study.

    PubMed

    Ritschl, Lucas M; Rau, Andrea; Güll, Florian D; diBora, Benjamin; Wolff, Klaus-Dietrich; Schönberger, Markus; Bauer, Franz X; Wintermantel, Erich; Loeffelbein, Denys J

    2016-04-01

    Computer-assisted design and computer-aided manufacturing (CAD/CAM) technology in nasoalveolar molding (NAM) should save time and manpower and reduce family input in cases of cleft lip and palate. Intraoral casts from 12 infants with complete unilateral cleft lip and palate were taken immediately after birth (T1) and after (T2) NAM treatment, digitalized, and transformed into STL data. The infants were randomized into Group 1 (n = 6) receiving conventional NAM treatment or Group 2 receiving CAD/CAM NAM (n = 6). We analyzed the following variables by using Geomagic software: intersegmental alveolar distance (ISAD); intersegmental lip distance (ISLD); nostril height cleft/noncleft (NHc/nc); nasal width cleft/noncleft (NWn/nc); and columella deviation angle (CDA). In both groups, all variables except NHnc and NWnc were changed significantly between T1 and T2. The analysis of the mean differences of the variables in Group 1 and 2 showed no significant differences, with a comparable incidence of clinical alterations such as skin or mucosal irritations. NAM plates can be produced virtually by using CAD/CAM technology. The CAD/CAM NAM results show no significant differences from the conventional technique. We present our clinically usable virtual CAD/CAM workflow for producing a basic NAM plate. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  5. Influences of Light-emitting Diode Illumination Bleaching Technique on Nanohardness of Computer-aided Design and Computer-aided Manufacturing Ceramic Restorative Materials.

    PubMed

    Juntavee, Niwut; Juntavee, Apa; Saensutthawijit, Phuwiwat

    2018-02-01

    This study evaluated the effect of light-emitting diode (LED) illumination bleaching technique on the surface nanohardness of various computer-aided design and computer-aided manufacturing (CAD/CAM) ceramic materials. Twenty disk-shaped samples (width, length, and thickness = 10, 15, and 2 mm) were prepared from each of the ceramic materials for CAD/CAM, including Lava™ Ultimate (L V ), Vita Enamic® (E n ) IPS e.max® CAD (M e ), inCoris® TZI (I C ), and Prettau® zirconia (P r ). The samples from each type of ceramic were randomly divided into two groups based on the different bleaching techniques to be used on them, using 35% hydrogen peroxide with and without LED illumination. The ceramic disk samples were bleached according to the manufacturer's instruction. Surface hardness test was performed before and after bleaching using nanohardness tester with a Berkovich diamond indenter. The respective Vickers hardness number upon no bleaching and bleaching without or with LED illumination [mean ± standard deviation (SD)] for each type of ceramic were as follows: 102.52 ± 2.09, 101.04 ± 1.18, and 98.17 ± 1.15 for L V groups; 274.96 ± 5.41, 271.29 ± 5.94, and 268.20 ± 7.02 for E n groups; 640.74 ± 31.02, 631.70 ± 22.38, and 582.32 ± 33.88 for M e groups; 1,442.09 ± 35.07, 1,431.32 ± 28.80, and 1,336.51 ± 34.03 for I C groups; and 1,383.82 ± 33.87, 1,343.51 ± 38.75, and 1,295.96 ± 31.29 for P r groups. The results indicated surface hardness reduction following the bleaching procedure of varying degrees for different ceramic materials. Analysis of variance (ANOVA) revealed a significant reduction in surface hardness due to the effect of bleaching technique, ceramic material, and the interaction between bleaching technique and ceramic material (p < 0.05). Bleaching resulted in a diminution of the surface hardness of dental ceramic for CAD/CAM. Using 35% hydrogen peroxide bleaching agent with LED illumination exhibited more reduction in surface hardness of dental ceramic than what was observed without LED illumination. Clinicians should consider protection of the existing restoration while bleaching.

  6. Discoloration of various CAD/CAM blocks after immersion in coffee.

    PubMed

    Lauvahutanon, Sasipin; Shiozawa, Maho; Takahashi, Hidekazu; Iwasaki, Naohiko; Oki, Meiko; Finger, Werner J; Arksornnukit, Mansuang

    2017-02-01

    This study evaluated color differences (Δ E s) and translucency parameter changes (Δ TP s) of various computer-aided design/computer-aided manufacturing (CAD/CAM) blocks after immersion in coffee. Eight CAD/CAM blocks and four restorative composite resins were evaluated. The CIE L * a * b * values of 2.0 mm thick disk-shaped specimens were measured using the spectrophotometer on white and black backgrounds ( n = 6). The Δ E s and Δ TP s of one day, one week, and one month immersion in coffee or water were calculated. The values of each material were analyzed by two-way ANOVA and Tukey's multiple comparisons (α = 0.05). The Δ E s after prophylaxis paste polishing of 1 month coffee immersion specimens, water sorption and solubility were also evaluated. After one month in coffee, Δ E s of CAD/CAM composite resin blocks and restorative composites ranged from 1.6 to 3.7 and from 2.1 to 7.9, respectively, and Δ TP s decreased. The ANOVA of Δ E s and Δ TP s revealed significant differences in two main factors, immersion periods and media, and their interaction except for Δ E s of TEL (Telio CAD, Ivoclar Vivadent). The Δ E s significantly decreased after prophylaxis polishing except GRA (Gradia Block, GC). There was no significant correlation between Δ E s and water sorption or solubility in water. The Δ E s of CAD/CAM blocks after immersion in coffee varied among products and were comparable to those of restorative composite resins. The discoloration of CAD/CAM composite resin blocks could be effectively removed with prophylaxis paste polishing, while that of some restorative composites could not be removed.

  7. Implementing an integrated engineering data base system: A developer's experience and the application to IPAD

    NASA Technical Reports Server (NTRS)

    Bruce, E. A.

    1980-01-01

    The software developed by the IPAD project, a new and very powerful tool for the implementation of integrated Computer Aided Design (CAD) systems in the aerospace engineering community, is discussed. The IPAD software is a tool and, as such, can be well applied or misapplied in any particular environment. The many benefits of an integrated CAD system are well documented, but there are few such systems in existence, especially in the mechanical engineering disciplines, and therefore little available experience to guide the implementor.

  8. Color change of CAD-CAM materials and composite resin cements after thermocycling.

    PubMed

    Gürdal, Isil; Atay, Ayse; Eichberger, Marlis; Cal, Ebru; Üsümez, Aslihan; Stawarczyk, Bogna

    2018-04-24

    The color of resin cements and computer-aided-design and computer-aided-manufacturing (CAD-CAM) restorations may change with aging. The purpose of this in vitro study was to analyze the influence of thermocycling on the color of CAD-CAM materials with underlying resin cement. Seven different CAD-CAM materials, composite resins and glass-ceramics were cut into 0.7-mm and 1.2-mm thicknesses (n=10) and cemented with a dual-polymerizing resin cement, a light-polymerizing resin cement, and a preheated composite resin (N=420). Color values were measured by using spectrophotometry. Specimens were subjected to thermocycling (5°C and 55°C; 5000 cycles). The measured color difference (ΔE) data were analyzed by using descriptive statistics. Normality of data distribution was tested by using the Kolmogorov-Smirnov test. Three-way and 1-way ANOVA followed by the Scheffé post-hoc test and unpaired 2-sample Student t test were computed to determine the significant differences among the tested parameters (α=.05). ΔE values were significantly influenced by the CAD-CAM material (η p 2 =0.85, P<.001) and the resin composite cement (η P 2 =0.03, P=.003) but were not influenced by thickness (P=.179). Significant interactions were present among thickness, cement, and CAD-CAM materials (P<.001). Vita Suprinity and GC Cerasmart showed significantly the lowest ΔE values (P<.001). The highest ΔE values were observed for IPS Empress CAD. The dual-polymerizing resin cement showed significantly lower ΔE values than the preheated composite resin (P=.003). Restoration materials and composite resin cement types used for cementation influence the amount of color change due to aging. Copyright © 2018 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  9. Development of personalized annuloplasty rings: combination of CT images and CAD-CAM tools.

    PubMed

    Díaz Lantada, Andrés; Valle-Fernández, Raquel Del; Morgado, Pilar Lafont; Muñoz-García, Julio; Muñoz Sanz, José Luis; Munoz-Guijosa, Juan Manuel; Otero, Javier Echávarri

    2010-02-01

    Although the use of personalized annuloplasty rings manufactured for each patient according to the size and morphology of their valve complex could be beneficial for the treatment of mitral insufficiency, this possibility has been limited for reasons of time-lines and costs as well as for design and manufacturing difficulties, as has been the case with other personalized implant and prosthetic developments. However, the present quality of medical image capture equipment together with the benefits to be had from computer-aided design and manufacturing technologies (CAD-CAM) and the capabilities furnished by rapid prototyping technologies, present new opportunities for a personalized response to the development of implants and prostheses, the social impact of which could turn out to be highly positive. This paper sets out a personalized development of an annuloplasty ring based on the combined use of information from medical imaging, from CAD-CAM design programs and prototype manufacture using rapid prototyping technologies.

  10. Automated image-based colon cleansing for laxative-free CT colonography computer-aided polyp detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Linguraru, Marius George; Panjwani, Neil; Fletcher, Joel G.

    2011-12-15

    Purpose: To evaluate the performance of a computer-aided detection (CAD) system for detecting colonic polyps at noncathartic computed tomography colonography (CTC) in conjunction with an automated image-based colon cleansing algorithm. Methods: An automated colon cleansing algorithm was designed to detect and subtract tagged-stool, accounting for heterogeneity and poor tagging, to be used in conjunction with a colon CAD system. The method is locally adaptive and combines intensity, shape, and texture analysis with probabilistic optimization. CTC data from cathartic-free bowel preparation were acquired for testing and training the parameters. Patients underwent various colonic preparations with barium or Gastroview in divided dosesmore » over 48 h before scanning. No laxatives were administered and no dietary modifications were required. Cases were selected from a polyp-enriched cohort and included scans in which at least 90% of the solid stool was visually estimated to be tagged and each colonic segment was distended in either the prone or supine view. The CAD system was run comparatively with and without the stool subtraction algorithm. Results: The dataset comprised 38 CTC scans from prone and/or supine scans of 19 patients containing 44 polyps larger than 10 mm (22 unique polyps, if matched between prone and supine scans). The results are robust on fine details around folds, thin-stool linings on the colonic wall, near polyps and in large fluid/stool pools. The sensitivity of the CAD system is 70.5% per polyp at a rate of 5.75 false positives/scan without using the stool subtraction module. This detection improved significantly (p = 0.009) after automated colon cleansing on cathartic-free data to 86.4% true positive rate at 5.75 false positives/scan. Conclusions: An automated image-based colon cleansing algorithm designed to overcome the challenges of the noncathartic colon significantly improves the sensitivity of colon CAD by approximately 15%.« less

  11. Novel method of fabricating individual trays for maxillectomy patients by computer-aided design and rapid prototyping.

    PubMed

    Huang, Zhi; Wang, Xin-zhi; Hou, Yue-Zhong

    2015-02-01

    Making impressions for maxillectomy patients is an essential but difficult task. This study developed a novel method to fabricate individual trays by computer-aided design (CAD) and rapid prototyping (RP) to simplify the process and enhance patient safety. Five unilateral maxillectomy patients were recruited for this study. For each patient, a computed tomography (CT) scan was taken. Based on the 3D surface reconstruction of the target area, an individual tray was manufactured by CAD/RP. With a conventional custom tray as control, two final impressions were made using the different types of tray for each patient. The trays were sectioned, and in each section the thickness of the material was measured at six evenly distributed points. Descriptive statistics and paired t-test were used to examine the difference of the impression thickness. SAS 9.3 was applied in the statistical analysis. Afterwards, all casts were then optically 3D scanned and compared digitally to evaluate the feasibility of this method. Impressions of all five maxillectomy patients were successfully made with individual trays fabricated by CAD/RP and traditional trays. The descriptive statistics of impression thickness measurement showed slightly more uneven results in the traditional trays, but no statistical significance was shown. A 3D digital comparison showed acceptable discrepancies within 1 mm in the majority of cast areas. The largest difference of 3 mm was observed in the buccal wall of the defective areas. Moderate deviations of 1 to 2 mm were detected in the buccal and labial vestibular groove areas. This study confirmed the feasibility of a novel method of fabricating individual trays by CAD/RP. Impressions made by individual trays manufactured using CAD/RP had a uniform thickness, with an acceptable level of accuracy compared to those made through conventional processes. © 2014 by the American College of Prosthodontists.

  12. Job expansion : an additional benefit of a computer aided dispatch/automatic vehicle locator (CAD/AVL) system

    DOT National Transportation Integrated Search

    2000-03-01

    The Denver Regional Transportation District (RTD) acquired a CAD/AVL system that became fully operational in 1996. The CAD/AVL system added radio channels and covert alarms in buses, located vehicles in real time, and monitored schedule adherence. Th...

  13. Parallels in Computer-Aided Design Framework and Software Development Environment Efforts.

    DTIC Science & Technology

    1992-05-01

    de - sign kits, and tool and design management frameworks. Also, books about software engineer- ing environments [Long 91] and electronic design...tool integration [Zarrella 90], and agreement upon a universal de - sign automation framework, such as the CAD Framework Initiative (CFI) [Malasky 91...ments: identification, control, status accounting, and audit and review. The paper by Dart ex- tracts 15 CM concepts from existing SDEs and tools

  14. Computer-Aided Diagnosis in Medical Imaging: Historical Review, Current Status and Future Potential

    PubMed Central

    Doi, Kunio

    2007-01-01

    Computer-aided diagnosis (CAD) has become one of the major research subjects in medical imaging and diagnostic radiology. In this article, the motivation and philosophy for early development of CAD schemes are presented together with the current status and future potential of CAD in a PACS environment. With CAD, radiologists use the computer output as a “second opinion” and make the final decisions. CAD is a concept established by taking into account equally the roles of physicians and computers, whereas automated computer diagnosis is a concept based on computer algorithms only. With CAD, the performance by computers does not have to be comparable to or better than that by physicians, but needs to be complementary to that by physicians. In fact, a large number of CAD systems have been employed for assisting physicians in the early detection of breast cancers on mammograms. A CAD scheme that makes use of lateral chest images has the potential to improve the overall performance in the detection of lung nodules when combined with another CAD scheme for PA chest images. Because vertebral fractures can be detected reliably by computer on lateral chest radiographs, radiologists’ accuracy in the detection of vertebral fractures would be improved by the use of CAD, and thus early diagnosis of osteoporosis would become possible. In MRA, a CAD system has been developed for assisting radiologists in the detection of intracranial aneurysms. On successive bone scan images, a CAD scheme for detection of interval changes has been developed by use of temporal subtraction images. In the future, many CAD schemes could be assembled as packages and implemented as a part of PACS. For example, the package for chest CAD may include the computerized detection of lung nodules, interstitial opacities, cardiomegaly, vertebral fractures, and interval changes in chest radiographs as well as the computerized classification of benign and malignant nodules and the differential diagnosis of interstitial lung diseases. In order to assist in the differential diagnosis, it would be possible to search for and retrieve images (or lesions) with known pathology, which would be very similar to a new unknown case, from PACS when a reliable and useful method has been developed for quantifying the similarity of a pair of images for visual comparison by radiologists. PMID:17349778

  15. A review of intelligent systems for heart sound signal analysis.

    PubMed

    Nabih-Ali, Mohammed; El-Dahshan, El-Sayed A; Yahia, Ashraf S

    2017-10-01

    Intelligent computer-aided diagnosis (CAD) systems can enhance the diagnostic capabilities of physicians and reduce the time required for accurate diagnosis. CAD systems could provide physicians with a suggestion about the diagnostic of heart diseases. The objective of this paper is to review the recent published preprocessing, feature extraction and classification techniques and their state of the art of phonocardiogram (PCG) signal analysis. Published literature reviewed in this paper shows the potential of machine learning techniques as a design tool in PCG CAD systems and reveals that the CAD systems for PCG signal analysis are still an open problem. Related studies are compared to their datasets, feature extraction techniques and the classifiers they used. Current achievements and limitations in developing CAD systems for PCG signal analysis using machine learning techniques are presented and discussed. In the light of this review, a number of future research directions for PCG signal analysis are provided.

  16. A dental vision system for accurate 3D tooth modeling.

    PubMed

    Zhang, Li; Alemzadeh, K

    2006-01-01

    This paper describes an active vision system based reverse engineering approach to extract the three-dimensional (3D) geometric information from dental teeth and transfer this information into Computer-Aided Design/Computer-Aided Manufacture (CAD/CAM) systems to improve the accuracy of 3D teeth models and at the same time improve the quality of the construction units to help patient care. The vision system involves the development of a dental vision rig, edge detection, boundary tracing and fast & accurate 3D modeling from a sequence of sliced silhouettes of physical models. The rig is designed using engineering design methods such as a concept selection matrix and weighted objectives evaluation chart. Reconstruction results and accuracy evaluation are presented on digitizing different teeth models.

  17. In vitro fatigue tests and in silico finite element analysis of dental implants with different fixture/abutment joint types using computer-aided design models.

    PubMed

    Yamaguchi, Satoshi; Yamanishi, Yasufumi; Machado, Lucas S; Matsumoto, Shuji; Tovar, Nick; Coelho, Paulo G; Thompson, Van P; Imazato, Satoshi

    2018-01-01

    The aim of this study was to evaluate fatigue resistance of dental fixtures with two different fixture-abutment connections by in vitro fatigue testing and in silico three-dimensional finite element analysis (3D FEA) using original computer-aided design (CAD) models. Dental implant fixtures with external connection (EX) or internal connection (IN) abutments were fabricated from original CAD models using grade IV titanium and step-stress accelerated life testing was performed. Fatigue cycles and loads were assessed by Weibull analysis, and fatigue cracking was observed by micro-computed tomography and a stereomicroscope with high dynamic range software. Using the same CAD models, displacement vectors of implant components were also analyzed by 3D FEA. Angles of the fractured line occurring at fixture platforms in vitro and of displacement vectors corresponding to the fractured line in silico were compared by two-way ANOVA. Fatigue testing showed significantly greater reliability for IN than EX (p<0.001). Fatigue crack initiation was primarily observed at implant fixture platforms. FEA demonstrated that crack lines of both implant systems in vitro were observed in the same direction as displacement vectors of the implant fixtures in silico. In silico displacement vectors in the implant fixture are insightful for geometric development of dental implants to reduce complex interactions leading to fatigue failure. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  18. Effects of Computer-Aided Manufacturing Technology on Precision of Clinical Metal-Free Restorations.

    PubMed

    Lee, Ki-Hong; Yeo, In-Sung; Wu, Benjamin M; Yang, Jae-Ho; Han, Jung-Suk; Kim, Sung-Hun; Yi, Yang-Jin; Kwon, Taek-Ka

    2015-01-01

    The purpose of this study was to investigate the marginal fit of metal-free crowns made by three different computer-aided design/computer-aided manufacturing (CAD/CAM) systems. The maxillary left first premolar of a dentiform was prepared for all-ceramic crown restoration. Thirty all-ceramic premolar crowns were made, ten each manufactured by the Lava system, Cercon, and Cerec. Ten metal ceramic gold (MCG) crowns served as control. The marginal gap of each sample was measured under a stereoscopic microscope at 75x magnification after cementation. One-way ANOVA and the Duncan's post hoc test were used for data analysis at the significance level of 0.05. The mean (standard deviation) marginal gaps were 70.5 (34.4) μm for the MCG crowns, 87.2 (22.8) μm for Lava, 58.5 (17.6) μm for Cercon, and 72.3 (30.8) μm for Cerec. There were no significant differences in the marginal fit among the groups except that the Cercon crowns had significantly smaller marginal gaps than the Lava crowns (P < 0.001). Within the limitation of this study, all the metal-free restorations made by the digital CAD/CAM systems had clinically acceptable marginal accuracy.

  19. Recent advances in the reconstruction of cranio-maxillofacial defects using computer-aided design/computer-aided manufacturing.

    PubMed

    Oh, Ji-Hyeon

    2018-12-01

    With the development of computer-aided design/computer-aided manufacturing (CAD/CAM) technology, it has been possible to reconstruct the cranio-maxillofacial defect with more accurate preoperative planning, precise patient-specific implants (PSIs), and shorter operation times. The manufacturing processes include subtractive manufacturing and additive manufacturing and should be selected in consideration of the material type, available technology, post-processing, accuracy, lead time, properties, and surface quality. Materials such as titanium, polyethylene, polyetheretherketone (PEEK), hydroxyapatite (HA), poly-DL-lactic acid (PDLLA), polylactide-co-glycolide acid (PLGA), and calcium phosphate are used. Design methods for the reconstruction of cranio-maxillofacial defects include the use of a pre-operative model printed with pre-operative data, printing a cutting guide or template after virtual surgery, a model after virtual surgery printed with reconstructed data using a mirror image, and manufacturing PSIs by directly obtaining PSI data after reconstruction using a mirror image. By selecting the appropriate design method, manufacturing process, and implant material according to the case, it is possible to obtain a more accurate surgical procedure, reduced operation time, the prevention of various complications that can occur using the traditional method, and predictive results compared to the traditional method.

  20. Environmental Testing and Thermal Analysis of the NPS Solar Cell Array Tester (NPS-SCAT) CubeSat

    DTIC Science & Technology

    2011-06-01

    BCR Battery Charge Regulator C&DH Command and Data Handling CAD Computer Aided Design CDR Critical Design Review CFT Comprehensive Functional Test ...CPT Comprehensive Performance Test CoM Center of Mass COTS Commercial Off-the-Shelf CTB Cargo Transfer Bag EDU Engineering Design Unit EPS...and inexpensive solution. 2 C. ENVIRONMENTAL TESTING Environmental testing is an important element of the design and testing of a satellite. By

  1. Analysis of components of variance in multiple-reader studies of computer-aided diagnosis with different tasks

    NASA Astrophysics Data System (ADS)

    Beiden, Sergey V.; Wagner, Robert F.; Campbell, Gregory; Metz, Charles E.; Chan, Heang-Ping; Nishikawa, Robert M.; Schnall, Mitchell D.; Jiang, Yulei

    2001-06-01

    In recent years, the multiple-reader, multiple-case (MRMC) study paradigm has become widespread for receiver operating characteristic (ROC) assessment of systems for diagnostic imaging and computer-aided diagnosis. We review how MRMC data can be analyzed in terms of the multiple components of the variance (case, reader, interactions) observed in those studies. Such information is useful for the design of pivotal studies from results of a pilot study and also for studying the effects of reader training. Recently, several of the present authors have demonstrated methods to generalize the analysis of multiple variance components to the case where unaided readers of diagnostic images are compared with readers who receive the benefit of a computer assist (CAD). For this case it is necessary to model the possibility that several of the components of variance might be reduced when readers incorporate the computer assist, compared to the unaided reading condition. We review results of this kind of analysis on three previously published MRMC studies, two of which were applications of CAD to diagnostic mammography and one was an application of CAD to screening mammography. The results for the three cases are seen to differ, depending on the reader population sampled and the task of interest. Thus, it is not possible to generalize a particular analysis of variance components beyond the tasks and populations actually investigated.

  2. Learning through Plastic Filament Extrusion

    ERIC Educational Resources Information Center

    Orr, Taylor; Flowers, Jim

    2015-01-01

    3D printing is becoming ever more popular in both the manufacturing world as well as in technology and engineering education classrooms all over the United States. 3D printing is an additive manufacturing process in which successive layers of material are built up to produce three-dimensional objects from computer-aided design (CAD) files, making…

  3. Selection of a Man-Modelling CAD (Computer-Aided Design),

    DTIC Science & Technology

    1985-09-01

    OPTIONS link-length input options internal dimensions - V V external dimensions V V V percentile values V V V absolute values (mm) V V/ V somatotypes V...specific data .035 A3 somatotype representation .020 A4 a-typical postures possible .035 * A5 flesh contour representation .040 A6 multiple number of

  4. Effectiveness and efficiency of a CAD/CAM orthodontic bracket system.

    PubMed

    Brown, Matthew W; Koroluk, Lorne; Ko, Ching-Chang; Zhang, Kai; Chen, Mengqi; Nguyen, Tung

    2015-12-01

    The first straight-wire appliance was introduced over 40 years ago to increase the consistency and efficiency of orthodontic treatment. More recently, computer-aided design and computer-aided manufacturing (CAD/CAM) technology has been used to create individualized orthodontic appliances. The purpose of this study was to investigate the clinical effectiveness and efficiency of CAD/CAM customized orthodontic appliances compared with direct and indirect bonded stock orthodontic brackets. This retrospective study included 3 treatment groups: group 1 patients were direct bonded with self-ligating appliances, group 2 patients were indirect bonded with self-ligating appliances, and group 3 patients were indirect bonded with CAD/CAM self-ligating appliances. Complete pretreatment and posttreatment records were obtained for all patients. The American Board of Orthodontics (ABO) Discrepancy Index was used to evaluate the pretreatment records, and the posttreatment outcomes were analyzed using the ABO Cast-Radiograph Evaluation. All data collection and analysis were completed by 1 evaluator. There were no statistically significant differences in the ABO Discrepancy Index or the ABO Cast-Radiograph Evaluation among the groups. Treatment times for the 3 groups were significantly different; the CAD/CAM group was the shortest at 13.8 ± 3.4 months, compared with 21.9 ± 5.0 and 16.9 ± 4.1 months for the direct bonded and indirect bonded groups, respectively. The number of treatment appointments for the CAD/CAM group was significantly fewer than for the direct bonded group. The CAD/CAM orthodontic bracket system evaluated in this study was as effective in treatment outcome measures as were standard brackets bonded both directly and indirectly. The CAD/CAM appliance was more efficient in regard to treatment duration, although the decrease in total archwire appointments was minimal. Further investigation is needed to better quantify the clinical benefits of CAD/CAM orthodontic appliances. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  5. Comparison of Flexural Strength of Different CAD/CAM PMMA-Based Polymers.

    PubMed

    Alp, Gülce; Murat, Sema; Yilmaz, Burak

    2018-01-28

    To compare the flexural strength of different computer-aided design/computer-aided manufacturing (CAD/CAM) poly(methyl methacrylate)-based (PMMA) polymers and conventional interim resin materials after thermocycling. Rectangular-shaped specimens (n = 15, for each material) (25 × 2 × 2 mm 3 ) were fabricated from 3 CAD/CAM PMMA-based polymers (Telio CAD [T]; M-PM-Disc [M]; Polident-PMMA [P]), 1 bis-acrylate composite resin (Protemp 4 [PT]), and 1 conventional PMMA (ArtConcept Artegral Dentine [C]) according to ISO 10477:2004 Standards (Dentistry-Polymer-Based Crown and Bridge Materials). The specimens were subjected to 10,000 thermocycles (5 to 55°C). Three-point flexural strength of the specimens was tested in a universal testing machine at a 1.0 mm/min crosshead speed, and the flexural strength data (σ) were calculated (MPa). The flexural strength values were statistically analyzed using 1-way ANOVA, and Tukey HSD post-hoc test for multiple comparisons (α = 0.05). Flexural strength values ranged between 66.1 ± 13.1 and 131.9 ± 19.8 MPa. There were significant differences among the flexural strengths of tested materials, except for between T and P CAD/CAM PMMA-based polymers (p > 0.05). CAD/CAM PMMA-based polymer M had the highest flexural strength and conventional PMMA had the lowest (p < 0.05). CAD/CAM PMMA-based T and P polymers had significantly higher flexural strength than the bis-acrylate composite resin (p < 0.05), and conventional PMMA (p < 0.0001), and significantly lower flexural strength compared to CAD/CAM PMMA-based M (p < 0.05). The flexural strength of CAD/CAM PMMA-based polymers was greater than the flexural strength of bis-acrylate composite resin, which had a greater flexural strength compared to conventional PMMA resin. © 2018 by the American College of Prosthodontists.

  6. Repairability of CAD/CAM high-density PMMA- and composite-based polymers.

    PubMed

    Wiegand, Annette; Stucki, Lukas; Hoffmann, Robin; Attin, Thomas; Stawarczyk, Bogna

    2015-11-01

    The study aimed to analyse the shear bond strength of computer-aided design and computer-aided manufacturing (CAD/CAM) polymethyl methacrylate (PMMA)- and composite-based polymer materials repaired with a conventional methacrylate-based composite after different surface pretreatments. Each 48 specimens was prepared from six different CAD/CAM polymer materials (Ambarino high-class, artBloc Temp, CAD-Temp, Lava Ultimate, Telio CAD, Everest C-Temp) and a conventional dimethacrylate-based composite (Filtek Supreme XTE, control) and aged by thermal cycling (5000 cycles, 5-55 °C). The surfaces were left untreated or were pretreated by mechanical roughening, aluminium oxide air abrasion or silica coating/silanization (each subgroup n = 12). The surfaces were further conditioned with an etch&rinse adhesive (OptiBond FL) before the repair composite (Filtek Supreme XTE) was adhered to the surface. After further thermal cycling, shear bond strength was tested, and failure modes were assessed. Shear bond strength was statistically analysed by two- and one-way ANOVAs and Weibull statistics, failure mode by chi(2) test (p ≤ 0.05). Shear bond strength was highest for silica coating/silanization > aluminium oxide air abrasion = mechanical roughening > no surface pretreatment. Independently of the repair pretreatment, highest bond strength values were observed in the control group and for the composite-based Everest C-Temp and Ambarino high-class, while PMMA-based materials (artBloc Temp, CAD-Temp and Telio CAD) presented significantly lowest values. For all materials, repair without any surface pretreatment resulted in adhesive failures only, which mostly were reduced when surface pretreatment was performed. Repair of CAD/CAM high-density polymers requires surface pretreatment prior to adhesive and composite application. However, four out of six of the tested CAD/CAM materials did not achieve the repair bond strength of a conventional dimethacrylate-based composite. Repair of PMMA- and composite-based polymers can be achieved by surface pretreatment followed by application of an adhesive and a conventional methacrylate-based composite.

  7. Precision Fit of Screw-Retained Implant-Supported Fixed Dental Prostheses Fabricated by CAD/CAM, Copy-Milling, and Conventional Methods.

    PubMed

    de França, Danilo Gonzaga; Morais, Maria Helena; das Neves, Flávio D; Carreiro, Adriana Fonte; Barbosa, Gustavo As

    The aim of this study was to evaluate the effectiveness of fabrication methods (computer-aided design/computer-aided manufacture [CAD/CAM], copy-milling, and conventional casting) in the fit accuracy of three-unit, screw-retained fixed dental prostheses. Sixteen three-unit implant-supported screw-retained frameworks were fabricated to fit an in vitro model. Eight frameworks were fabricated using the CAD/CAM system, four in zirconia and four in cobalt-chromium. Four zirconia frameworks were fabricated using the copy-milled system, and four were cast in cobalt-chromium using conventional casting with premachined abutments. The vertical and horizontal misfit at the implant-framework interface was measured using scanning electron microscopy at ×250. The results for vertical misfit were analyzed using Kruskal-Wallis and Mann-Whitney tests. The horizontal misfits were categorized as underextended, equally extended, or overextended. Statistical analysis established differences between groups according to the chi-square test (α = .05). The mean vertical misfit was 5.9 ± 3.6 μm for CAD/CAM-fabricated zirconia, 1.2 ± 2.2 μm for CAD/CAM-fabricated cobalt-chromium frameworks, 7.6 ± 9.2 μm for copy-milling-fabricated zirconia frameworks, and 11.8 (9.8) μm for conventionally fabricated frameworks. The Mann-Whitney test revealed significant differences between all but the zirconia-fabricated frameworks. A significant association was observed between the horizontal misfits and the fabrication method. The percentage of horizontal misfits that were underextended and overextended was higher in milled zirconia (83.3%), CAD/CAM cobaltchromium (66.7%), cast cobalt-chromium (58.3%), and CAD/CAM zirconia (33.3%) frameworks. CAD/CAM-fabricated frameworks exhibit better vertical misfit and low variability compared with copy-milled and conventionally fabricated frameworks. The percentage of interfaces equally extended was higher when CAD/CAM and zirconia were used.

  8. Computer-aided diagnosis in radiological imaging: current status and future challenges

    NASA Astrophysics Data System (ADS)

    Doi, Kunio

    2009-10-01

    Computer-aided diagnosis (CAD) has become one of the major research subjects in medical imaging and diagnostic radiology. Many different types of CAD schemes are being developed for detection and/or characterization of various lesions in medical imaging, including conventional projection radiography, CT, MRI, and ultrasound imaging. Commercial systems for detection of breast lesions on mammograms have been developed and have received FDA approval for clinical use. CAD may be defined as a diagnosis made by a physician who takes into account the computer output as a "second opinion". The purpose of CAD is to improve the quality and productivity of physicians in their interpretation of radiologic images. The quality of their work can be improved in terms of the accuracy and consistency of their radiologic diagnoses. In addition, the productivity of radiologists is expected to be improved by a reduction in the time required for their image readings. The computer output is derived from quantitative analysis of radiologic images by use of various methods and techniques in computer vision, artificial intelligence, and artificial neural networks (ANNs). The computer output may indicate a number of important parameters, for example, the locations of potential lesions such as lung cancer and breast cancer, the likelihood of malignancy of detected lesions, and the likelihood of various diseases based on differential diagnosis in a given image and clinical parameters. In this review article, the basic concept of CAD is first defined, and the current status of CAD research is then described. In addition, the potential of CAD in the future is discussed and predicted.

  9. [Presurgical alveolar molding using computer aided design in infants with unilateral complete cleft lip and palate].

    PubMed

    Zgong, Xin; Yu, Quan; Yu, Zhe-yuan; Wang, Guo-min; Qian, Yu-fen

    2012-04-01

    To establish a new method of presurgical alveolar molding using computer aided design(CAD) in infants with complete unilateral cleft lip and palate (UCLP). Ten infants with complete UCLP were recruited. A maxillary impression was taken at the first examination after birth. The study model was scanned by a non-contact three-dimensional laser scanner and a digital model was constructed and analyzed to simulate the alveolar molding procedure with reverse engineering software (RapidForm 2006). The digital geometrical data were exported to produce a scale model using rapid prototyping technology. The whole set of appliances was fabricated based on these solid models. The digital model could be viewed and measured from any direction by the software. By the end of the NAM treatment before surgical lip repair, the cleft was narrowed and the malformation of alveolar segments was aligned normally, significantly improving nasal symmetry and nostril shape. Presurgical NAM using CAD could simplify the treatment procedure and estimate the treatment objective, which enabled precise control of the force and direction of the alveolar segments movement.

  10. Inspection of aeronautical mechanical parts with a pan-tilt-zoom camera: an approach guided by the computer-aided design model

    NASA Astrophysics Data System (ADS)

    Viana, Ilisio; Orteu, Jean-José; Cornille, Nicolas; Bugarin, Florian

    2015-11-01

    We focus on quality control of mechanical parts in aeronautical context using a single pan-tilt-zoom (PTZ) camera and a computer-aided design (CAD) model of the mechanical part. We use the CAD model to create a theoretical image of the element to be checked, which is further matched with the sensed image of the element to be inspected, using a graph theory-based approach. The matching is carried out in two stages. First, the two images are used to create two attributed graphs representing the primitives (ellipses and line segments) in the images. In the second stage, the graphs are matched using a similarity function built from the primitive parameters. The similarity scores of the matching are injected in the edges of a bipartite graph. A best-match-search procedure in the bipartite graph guarantees the uniqueness of the match solution. The method achieves promising performance in tests with synthetic data including missing elements, displaced elements, size changes, and combinations of these cases. The results open good prospects for using the method with realistic data.

  11. Harnessing the Potential of Additive Manufacturing

    DTIC Science & Technology

    2016-12-01

    manufacturing age, which is dominated by standards for materials, processes and process control. Conventional manufacturing is based upon a design that is...documented either in a drawing or a computer-aided design (CAD) file. The manufacturing team then develops a docu- mented public or private process for...31 Defense AT&L: November-December 2016 Harnessing the Potential of Additive Manufacturing Bill Decker Decker is director of Technology

  12. Computer-aided detection systems to improve lung cancer early diagnosis: state-of-the-art and challenges

    NASA Astrophysics Data System (ADS)

    Traverso, A.; Lopez Torres, E.; Fantacci, M. E.; Cerello, P.

    2017-05-01

    Lung cancer is one of the most lethal types of cancer, because its early diagnosis is not good enough. In fact, the detection of pulmonary nodule, potential lung cancers, in Computed Tomography scans is a very challenging and time-consuming task for radiologists. To support radiologists, researchers have developed Computer-Aided Diagnosis (CAD) systems for the automated detection of pulmonary nodules in chest Computed Tomography scans. Despite the high level of technological developments and the proved benefits on the overall detection performance, the usage of Computer-Aided Diagnosis in clinical practice is far from being a common procedure. In this paper we investigate the causes underlying this discrepancy and present a solution to tackle it: the M5L WEB- and Cloud-based on-demand Computer-Aided Diagnosis. In addition, we prove how the combination of traditional imaging processing techniques with state-of-art advanced classification algorithms allows to build a system whose performance could be much larger than any Computer-Aided Diagnosis developed so far. This outcome opens the possibility to use the CAD as clinical decision support for radiologists.

  13. Mission Critical Computer Resources Management Guide.

    DTIC Science & Technology

    1990-01-01

    another task and Ada fixes priorities at con- ported. The goal of the early developers of pilation time and is therefore inflexible to thc Ada was to...may support thc use of computer stitute are investigating the technical and aided design and manufacturing management advances required to answer (CAD...the Commerce Business Daily ( CBD ). intended, and special contract clauses to be It will be used by procurement personnel to used. determine potential

  14. Geometric and computer-aided spline hob modeling

    NASA Astrophysics Data System (ADS)

    Brailov, I. G.; Myasoedova, T. M.; Panchuk, K. L.; Krysova, I. V.; Rogoza, YU A.

    2018-03-01

    The paper considers acquiring the spline hob geometric model. The objective of the research is the development of a mathematical model of spline hob for spline shaft machining. The structure of the spline hob is described taking into consideration the motion in parameters of the machine tool system of cutting edge positioning and orientation. Computer-aided study is performed with the use of CAD and on the basis of 3D modeling methods. Vector representation of cutting edge geometry is accepted as the principal method of spline hob mathematical model development. The paper defines the correlations described by parametric vector functions representing helical cutting edges designed for spline shaft machining with consideration for helical movement in two dimensions. An application for acquiring the 3D model of spline hob is developed on the basis of AutoLISP for AutoCAD environment. The application presents the opportunity for the use of the acquired model for milling process imitation. An example of evaluation, analytical representation and computer modeling of the proposed geometrical model is reviewed. In the mentioned example, a calculation of key spline hob parameters assuring the capability of hobbing a spline shaft of standard design is performed. The polygonal and solid spline hob 3D models are acquired by the use of imitational computer modeling.

  15. Marginal adaptation of CAD-CAM onlays: Influence of preparation design and impression technique.

    PubMed

    Lima, Fernanda Ferruzzi; Neto, Constantino Fernandes; Rubo, José H; Santos, Gildo Coelho; Moraes Coelho Santos, Maria Jacinta

    2018-03-15

    Factors that may affect the marginal adaptation of computer-aided design and computer-aided manufacturing (CAD-CAM) restorations include preparation design, impression technique, and CAD-CAM system. The influence of impression technique and preparation design on CAD-CAM partial coverage restorations has not been fully addressed. The purpose of this in vitro study was to investigate the influence of direct and indirect digital impression techniques and 2 preparation designs on the marginal adaptation of CAD-CAM onlays. Two mesio-occlusal buccal onlay preparations with reduction of the mesiobuccal cusp were made: conventional preparation (CP) with a 1.2-mm modified shoulder margin and modified preparation (MP) flat cuspal reduction without shoulder. Virtual models were generated from each preparation by using a digital scanner (BlueCam; Dentsply Sirona) from the plastic teeth (direct digital impression) or from the stone dies (indirect digital impression). Onlays were designed using a CAD-CAM system (CEREC 4.0; Dentsply Sirona), and nanoceramic resin blocks (Lava Ultimate Restorative; 3M ESPE) were milled using the CEREC MCX milling machine. Marginal discrepancy was evaluated using an optical stereomicroscope at ×25 magnification in 18 locations distributed along the margins of the preparation. The data were analyzed by using 3-way ANOVA followed by the Tukey HSD test (α=.05). CP presented a statistically significant reduced average marginal adaptation (59 ±50 μm) than did MP (69 ±58 μm) (P<.001). The Tukey HSD test showed the presence of a significantly larger marginal discrepancy in the mesial and buccal locations of MP when compared with CP. Regarding impression techniques, the buccal location presented the smallest average marginal discrepancy in restorations fabricated with indirect impression when compared with direct impression (42 ±33 μm and 60 ±39 μm) (P<.001). The results showed that conventional preparation with a modified shoulder margin presented improved marginal adaptation compared with modified preparation with flat cuspal reduction. Direct and indirect digital impression techniques produced restorations within a clinically acceptable range; however, the indirect impression technique resulted in the fabrication of restorations with superior marginal adaptation on the buccal location. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  16. Computer-aided detection of pulmonary embolism at CT pulmonary angiography: can it improve performance of inexperienced readers?

    PubMed

    Blackmon, Kevin N; Florin, Charles; Bogoni, Luca; McCain, Joshua W; Koonce, James D; Lee, Heon; Bastarrika, Gorka; Thilo, Christian; Costello, Philip; Salganicoff, Marcos; Joseph Schoepf, U

    2011-06-01

    To evaluate the effect of a computer-aided detection (CAD) algorithm on the performance of novice readers for detection of pulmonary embolism (PE) at CT pulmonary angiography (CTPA). We included CTPA examinations of 79 patients (50 female, 52 ± 18 years). Studies were evaluated by two independent inexperienced readers who marked all vessels containing PE. After 3 months all studies were reevaluated by the same two readers, this time aided by CAD prototype. A consensus read by three expert radiologists served as the reference standard. Statistical analysis used χ(2) and McNemar testing. Expert consensus revealed 119 PEs in 32 studies. For PE detection, the sensitivity of CAD alone was 78%. Inexperienced readers' initial interpretations had an average per-PE sensitivity of 50%, which improved to 71% (p < 0.001) with CAD as a second reader. False positives increased from 0.18 to 0.25 per study (p = 0.03). Per-study, the readers initially detected 27/32 positive studies (84%); with CAD this number increased to 29.5 studies (92%; p = 0.125). Our results suggest that CAD significantly improves the sensitivity of PE detection for inexperienced readers with a small but appreciable increase in the rate of false positives.

  17. Automated computation of femoral angles in dogs from three-dimensional computed tomography reconstructions: Comparison with manual techniques.

    PubMed

    Longo, F; Nicetto, T; Banzato, T; Savio, G; Drigo, M; Meneghello, R; Concheri, G; Isola, M

    2018-02-01

    The aim of this ex vivo study was to test a novel three-dimensional (3D) automated computer-aided design (CAD) method (aCAD) for the computation of femoral angles in dogs from 3D reconstructions of computed tomography (CT) images. The repeatability and reproducibility of three manual radiography, manual CT reconstructions and the aCAD method for the measurement of three femoral angles were evaluated: (1) anatomical lateral distal femoral angle (aLDFA); (2) femoral neck angle (FNA); and (3) femoral torsion angle (FTA). Femoral angles of 22 femurs obtained from 16 cadavers were measured by three blinded observers. Measurements were repeated three times by each observer for each diagnostic technique. Femoral angle measurements were analysed using a mixed effects linear model for repeated measures to determine the levels of intra-observer agreement (repeatability) and inter-observer agreement (reproducibility). Repeatability and reproducibility of measurements using the aCAD method were excellent (intra-class coefficients, ICCs≥0.98) for all three angles assessed. Manual radiography and CT exhibited excellent agreement for the aLDFA measurement (ICCs≥0.90). However, FNA repeatability and reproducibility were poor (ICCs<0.8), whereas FTA measurement showed slightly higher ICCs values, except for the radiographic reproducibility, which was poor (ICCs<0.8). The computation of the 3D aCAD method provided the highest repeatability and reproducibility among the tested methodologies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Performance of fusion algorithms for computer-aided detection and classification of mines in very shallow water obtained from testing in navy Fleet Battle Exercise-Hotel 2000

    NASA Astrophysics Data System (ADS)

    Ciany, Charles M.; Zurawski, William; Kerfoot, Ian

    2001-10-01

    The performance of Computer Aided Detection/Computer Aided Classification (CAD/CAC) Fusion algorithms on side-scan sonar images was evaluated using data taken at the Navy's's Fleet Battle Exercise-Hotel held in Panama City, Florida, in August 2000. A 2-of-3 binary fusion algorithm is shown to provide robust performance. The algorithm accepts the classification decisions and associated contact locations form three different CAD/CAC algorithms, clusters the contacts based on Euclidian distance, and then declares a valid target when a clustered contact is declared by at least 2 of the 3 individual algorithms. This simple binary fusion provided a 96 percent probability of correct classification at a false alarm rate of 0.14 false alarms per image per side. The performance represented a 3.8:1 reduction in false alarms over the best performing single CAD/CAC algorithm, with no loss in probability of correct classification.

  19. Computer-aided classification of lung nodules on computed tomography images via deep learning technique

    PubMed Central

    Hua, Kai-Lung; Hsu, Che-Hao; Hidayati, Shintami Chusnul; Cheng, Wen-Huang; Chen, Yu-Jen

    2015-01-01

    Lung cancer has a poor prognosis when not diagnosed early and unresectable lesions are present. The management of small lung nodules noted on computed tomography scan is controversial due to uncertain tumor characteristics. A conventional computer-aided diagnosis (CAD) scheme requires several image processing and pattern recognition steps to accomplish a quantitative tumor differentiation result. In such an ad hoc image analysis pipeline, every step depends heavily on the performance of the previous step. Accordingly, tuning of classification performance in a conventional CAD scheme is very complicated and arduous. Deep learning techniques, on the other hand, have the intrinsic advantage of an automatic exploitation feature and tuning of performance in a seamless fashion. In this study, we attempted to simplify the image analysis pipeline of conventional CAD with deep learning techniques. Specifically, we introduced models of a deep belief network and a convolutional neural network in the context of nodule classification in computed tomography images. Two baseline methods with feature computing steps were implemented for comparison. The experimental results suggest that deep learning methods could achieve better discriminative results and hold promise in the CAD application domain. PMID:26346558

  20. Computer-aided classification of lung nodules on computed tomography images via deep learning technique.

    PubMed

    Hua, Kai-Lung; Hsu, Che-Hao; Hidayati, Shintami Chusnul; Cheng, Wen-Huang; Chen, Yu-Jen

    2015-01-01

    Lung cancer has a poor prognosis when not diagnosed early and unresectable lesions are present. The management of small lung nodules noted on computed tomography scan is controversial due to uncertain tumor characteristics. A conventional computer-aided diagnosis (CAD) scheme requires several image processing and pattern recognition steps to accomplish a quantitative tumor differentiation result. In such an ad hoc image analysis pipeline, every step depends heavily on the performance of the previous step. Accordingly, tuning of classification performance in a conventional CAD scheme is very complicated and arduous. Deep learning techniques, on the other hand, have the intrinsic advantage of an automatic exploitation feature and tuning of performance in a seamless fashion. In this study, we attempted to simplify the image analysis pipeline of conventional CAD with deep learning techniques. Specifically, we introduced models of a deep belief network and a convolutional neural network in the context of nodule classification in computed tomography images. Two baseline methods with feature computing steps were implemented for comparison. The experimental results suggest that deep learning methods could achieve better discriminative results and hold promise in the CAD application domain.

  1. Dynamic MRI-based computer aided diagnostic systems for early detection of kidney transplant rejection: A survey

    NASA Astrophysics Data System (ADS)

    Mostapha, Mahmoud; Khalifa, Fahmi; Alansary, Amir; Soliman, Ahmed; Gimel'farb, Georgy; El-Baz, Ayman

    2013-10-01

    Early detection of renal transplant rejection is important to implement appropriate medical and immune therapy in patients with transplanted kidneys. In literature, a large number of computer-aided diagnostic (CAD) systems using different image modalities, such as ultrasound (US), magnetic resonance imaging (MRI), computed tomography (CT), and radionuclide imaging, have been proposed for early detection of kidney diseases. A typical CAD system for kidney diagnosis consists of a set of processing steps including: motion correction, segmentation of the kidney and/or its internal structures (e.g., cortex, medulla), construction of agent kinetic curves, functional parameter estimation, diagnosis, and assessment of the kidney status. In this paper, we survey the current state-of-the-art CAD systems that have been developed for kidney disease diagnosis using dynamic MRI. In addition, the paper addresses several challenges that researchers face in developing efficient, fast and reliable CAD systems for the early detection of kidney diseases.

  2. NASA Space Engineering Research Center for VLSI systems design

    NASA Technical Reports Server (NTRS)

    1991-01-01

    This annual review reports the center's activities and findings on very large scale integration (VLSI) systems design for 1990, including project status, financial support, publications, the NASA Space Engineering Research Center (SERC) Symposium on VLSI Design, research results, and outreach programs. Processor chips completed or under development are listed. Research results summarized include a design technique to harden complementary metal oxide semiconductors (CMOS) memory circuits against single event upset (SEU); improved circuit design procedures; and advances in computer aided design (CAD), communications, computer architectures, and reliability design. Also described is a high school teacher program that exposes teachers to the fundamentals of digital logic design.

  3. Complications with computer-aided designed/computer-assisted manufactured titanium and soldered gold bars for mandibular implant-overdentures: short-term observations.

    PubMed

    Katsoulis, Joannis; Wälchli, Julia; Kobel, Simone; Gholami, Hadi; Mericske-Stern, Regina

    2015-01-01

    Implant-overdentures supported by rigid bars provide stability in the edentulous atrophic mandible. However, fractures of solder joints and matrices, and loosening of screws and matrices were observed with soldered gold bars (G-bars). Computer-aided designed/computer-assisted manufactured (CAD/CAM) titanium bars (Ti-bars) may reduce technical complications due to enhanced material quality. To compare prosthetic-technical maintenance service of mandibular implant-overdentures supported by CAD/CAM Ti-bar and soldered G-bar. Edentulous patients were consecutively admitted for implant-prosthodontic treatment with a maxillary complete denture and a mandibular implant-overdenture connected to a rigid G-bar or Ti-bar. Maintenance service and problems with the implant-retention device complex and the prosthesis were recorded during minimally 3-4 years. Annual peri-implant crestal bone level changes (ΔBIC) were radiographically assessed. Data of 213 edentulous patients (mean age 68 ± 10 years), who had received a total of 477 tapered implants, were available. Ti-bar and G-bar comprised 101 and 112 patients with 231 and 246 implants, respectively. Ti-bar mostly exhibited distal bar extensions (96%) compared to 34% of G-bar (p < .001). Fracture rate of bars extensions (4.7% vs 14.8%, p < .001) and matrices (1% vs 13%, p < .001) was lower for Ti-bar. Matrices activation was required 2.4× less often in Ti-bar. ΔBIC remained stable for both groups. Implant overdentures supported by soldered gold bars or milled CAD/CAM Ti-bars are a successful treatment modality but require regular maintenance service. These short-term observations support the hypothesis that CAD/CAM Ti-bars reduce technical complications. Fracture location indicated that the titanium thickness around the screw-access hole should be increased. © 2013 Wiley Periodicals, Inc.

  4. Design Evaluation for Personnel, Training and Human Factors (DEPTH) Final Report.

    DTIC Science & Technology

    1998-01-17

    human activity was primarily intended to facilitate man-machine design analyses of complex systems. By importing computer aided design (CAD) data, the human figure models and analysis algorithms can help to ensure components can be seen, reached, lifted and removed by most maintainers. These simulations are also useful for logistics data capture, training, and task analysis. DEPTH was also found to be useful in obtaining task descriptions for technical

  5. Microcomputer Simulated CAD for Engineering Graphics.

    ERIC Educational Resources Information Center

    Huggins, David L.; Myers, Roy E.

    1983-01-01

    Describes a simulated computer-aided-graphics (CAD) program at The Pennsylvania State University. Rationale for the program, facilities, microcomputer equipment (Apple) used, and development of a software package for simulating applied engineering graphics are considered. (JN)

  6. Designing a combined casting mold for manufacture of a gasoline centrifugal pump body using CAD/CAM-systems

    NASA Astrophysics Data System (ADS)

    Galin, N. E.; Ogol, I. I.; Chervach, Yu B.; Dammer, V. Kh; Ru, Jia Hong

    2017-02-01

    The present paper examines designing of a combined casting mold for manufacture of a gasoline centrifugal pump body. The paper offers technological solutions for obtaining high quality castings at the testing stage of the finished mold. The paper is intended for practical use and prepared by order of JSC ‘Tomsk Electrical Engineering Plant’ using software and equipment of the department ‘Technologies of Computer-Aided Machinery Manufacturing’ of the Tomsk Polytechnic University (TPU) under the economic contract within state import substitution program. In preparing the paper, CAD/CAM-systems KOMPAS-3D and PowerMILL were used. In 2015, the designed casting mold was introduced into the production process at JSC ‘Tomsk Electrical Engineering Plant’.

  7. Use of MathCAD in a Pharmacokinetics Course for PharmD Students.

    ERIC Educational Resources Information Center

    Sullivan, Timothy J.

    1992-01-01

    This paper describes the application of the Student Edition of MathCAD as a computational aid in an introductory graduate level pharmacokinetics course. The program allows the student to perform mathematical calculations and analysis on a computer screen. The advantages and disadvantages of this application are discussed. (GLR)

  8. National Combustion Code, a Multidisciplinary Combustor Design System, Will Be Transferred to the Commercial Sector

    NASA Technical Reports Server (NTRS)

    Steele, Gynelle C.

    1999-01-01

    The NASA Lewis Research Center and Flow Parametrics will enter into an agreement to commercialize the National Combustion Code (NCC). This multidisciplinary combustor design system utilizes computer-aided design (CAD) tools for geometry creation, advanced mesh generators for creating solid model representations, a common framework for fluid flow and structural analyses, modern postprocessing tools, and parallel processing. This integrated system can facilitate and enhance various phases of the design and analysis process.

  9. A survey on computer aided diagnosis for ocular diseases

    PubMed Central

    2014-01-01

    Background Computer Aided Diagnosis (CAD), which can automate the detection process for ocular diseases, has attracted extensive attention from clinicians and researchers alike. It not only alleviates the burden on the clinicians by providing objective opinion with valuable insights, but also offers early detection and easy access for patients. Method We review ocular CAD methodologies for various data types. For each data type, we investigate the databases and the algorithms to detect different ocular diseases. Their advantages and shortcomings are analyzed and discussed. Result We have studied three types of data (i.e., clinical, genetic and imaging) that have been commonly used in existing methods for CAD. The recent developments in methods used in CAD of ocular diseases (such as Diabetic Retinopathy, Glaucoma, Age-related Macular Degeneration and Pathological Myopia) are investigated and summarized comprehensively. Conclusion While CAD for ocular diseases has shown considerable progress over the past years, the clinical importance of fully automatic CAD systems which are able to embed clinical knowledge and integrate heterogeneous data sources still show great potential for future breakthrough. PMID:25175552

  10. Multidisciplinary analysis and design of printed wiring boards

    NASA Astrophysics Data System (ADS)

    Fulton, Robert E.; Hughes, Joseph L.; Scott, Waymond R., Jr.; Umeagukwu, Charles; Yeh, Chao-Pin

    1991-04-01

    Modern printed wiring board design depends on electronic prototyping using computer-based simulation and design tools. Existing electrical computer-aided design (ECAD) tools emphasize circuit connectivity with only rudimentary analysis capabilities. This paper describes a prototype integrated PWB design environment denoted Thermal Structural Electromagnetic Testability (TSET) being developed at Georgia Tech in collaboration with companies in the electronics industry. TSET provides design guidance based on enhanced electrical and mechanical CAD capabilities including electromagnetic modeling testability analysis thermal management and solid mechanics analysis. TSET development is based on a strong analytical and theoretical science base and incorporates an integrated information framework and a common database design based on a systematic structured methodology.

  11. Gaps Analysis of Integrating Product Design, Manufacturing, and Quality Data in The Supply Chain Using Model-Based Definition.

    PubMed

    Trainer, Asa; Hedberg, Thomas; Feeney, Allison Barnard; Fischer, Kevin; Rosche, Phil

    2016-01-01

    Advances in information technology triggered a digital revolution that holds promise of reduced costs, improved productivity, and higher quality. To ride this wave of innovation, manufacturing enterprises are changing how product definitions are communicated - from paper to models. To achieve industry's vision of the Model-Based Enterprise (MBE), the MBE strategy must include model-based data interoperability from design to manufacturing and quality in the supply chain. The Model-Based Definition (MBD) is created by the original equipment manufacturer (OEM) using Computer-Aided Design (CAD) tools. This information is then shared with the supplier so that they can manufacture and inspect the physical parts. Today, suppliers predominantly use Computer-Aided Manufacturing (CAM) and Coordinate Measuring Machine (CMM) models for these tasks. Traditionally, the OEM has provided design data to the supplier in the form of two-dimensional (2D) drawings, but may also include a three-dimensional (3D)-shape-geometry model, often in a standards-based format such as ISO 10303-203:2011 (STEP AP203). The supplier then creates the respective CAM and CMM models and machine programs to produce and inspect the parts. In the MBE vision for model-based data exchange, the CAD model must include product-and-manufacturing information (PMI) in addition to the shape geometry. Today's CAD tools can generate models with embedded PMI. And, with the emergence of STEP AP242, a standards-based model with embedded PMI can now be shared downstream. The on-going research detailed in this paper seeks to investigate three concepts. First, that the ability to utilize a STEP AP242 model with embedded PMI for CAD-to-CAM and CAD-to-CMM data exchange is possible and valuable to the overall goal of a more efficient process. Second, the research identifies gaps in tools, standards, and processes that inhibit industry's ability to cost-effectively achieve model-based-data interoperability in the pursuit of the MBE vision. Finally, it also seeks to explore the interaction between CAD and CMM processes and determine if the concept of feedback from CAM and CMM back to CAD is feasible. The main goal of our study is to test the hypothesis that model-based-data interoperability from CAD-to-CAM and CAD-to-CMM is feasible through standards-based integration. This paper presents several barriers to model-based-data interoperability. Overall, the project team demonstrated the exchange of product definition data between CAD, CAM, and CMM systems using standards-based methods. While gaps in standards coverage were identified, the gaps should not stop industry's progress toward MBE. The results of our study provide evidence in support of an open-standards method to model-based-data interoperability, which would provide maximum value and impact to industry.

  12. Multidisciplinary analysis of actively controlled large flexible spacecraft

    NASA Technical Reports Server (NTRS)

    Cooper, Paul A.; Young, John W.; Sutter, Thomas R.

    1986-01-01

    The control of Flexible Structures (COFS) program has supported the development of an analysis capability at the Langley Research Center called the Integrated Multidisciplinary Analysis Tool (IMAT) which provides an efficient data storage and transfer capability among commercial computer codes to aid in the dynamic analysis of actively controlled structures. IMAT is a system of computer programs which transfers Computer-Aided-Design (CAD) configurations, structural finite element models, material property and stress information, structural and rigid-body dynamic model information, and linear system matrices for control law formulation among various commercial applications programs through a common database. Although general in its formulation, IMAT was developed specifically to aid in the evaluation of the structures. A description of the IMAT system and results of an application of the system are given.

  13. Marginal accuracy of computer-aided design- and computer-aided manufacturing-fabricated full-arch zirconia restoration

    PubMed Central

    Sirisathit, Issarawas

    2018-01-01

    Objective This study evaluated marginal accuracy of full-arch zirconia restoration fabricated from two digital computer-aided design and computer-aided manufacturing (CAD-CAM) systems (Trios-3 and CS3500) in comparison to conventional cast metal restoration. Materials and methods A stainless steel model comprising two canine and two molar abutments was used as a master model for full-arch reconstruction. The canine and molar abutments were machined in a cylindrical shape with 5° taper and chamfer margin. The CAD-CAM systems based on the digital approach were used to construct the full-arch zirconia restoration. The conventional cast metal restoration was fabricated according to a conventional lost-wax technique using nickel–chromium alloys. Ten restorations were fabricated from each system. The marginal accuracy of each restoration was determined at four locations for each abutment. An analysis of variance (ANOVA) and Tukey’s honest significant difference (HSD) multiple comparisons were used to determine statistically significant difference at 95% confidence interval. Results The mean values of marginal accuracy of restorations fabricated from conventional casting, Trios-3, and CS3500 were 48.59±4.16 μm, 53.50±5.66 μm, and 56.47±5.52 μm, respectively. ANOVA indicated significant difference in marginal fit of restorations among various systems. The marginal discrepancy of zirconia restoration fabricated from the CS3500 system demonstrated significantly larger gap than that fabricated from the 3Shape system (p<0.05). Tukey’s HSD multiple comparisons indicated that the zirconia restoration fabricated from either CS3500 or Trios-3 demonstrated a significantly larger marginal gap than the conventional cast metal restoration (p<0.05). Conclusion Full-arch zirconia restoration fabricated from the Trios-3 illustrated better marginal fits than that from the CS3500, although, both were slightly less accurate than the conventional cast restoration. However, the marginal discrepancies of restoration produced by both CAD-CAM systems were within the clinically acceptable range and satisfactorily precise to be suggested for construction full-arch zirconia restoration. PMID:29497334

  14. From Oss CAD to Bim for Cultural Heritage Digital Representation

    NASA Astrophysics Data System (ADS)

    Logothetis, S.; Karachaliou, E.; Stylianidis, E.

    2017-02-01

    The paper illustrates the use of open source Computer-aided design (CAD) environments in order to develop Building Information Modelling (BIM) tools able to manage 3D models in the field of cultural heritage. Nowadays, the development of Free and Open Source Software (FOSS) has been rapidly growing and their use tends to be consolidated. Although BIM technology is widely known and used, there is a lack of integrated open source platforms able to support all stages of Historic Building Information Modelling (HBIM) processes. The present research aims to use a FOSS CAD environment in order to develop BIM plug-ins which will be able to import and edit digital representations of cultural heritage models derived by photogrammetric methods.

  15. From Artisanal to CAD-CAM Blocks: State of the Art of Indirect Composites.

    PubMed

    Mainjot, A K; Dupont, N M; Oudkerk, J C; Dewael, T Y; Sadoun, M J

    2016-05-01

    Indirect composites have been undergoing an impressive evolution over the last few years. Specifically, recent developments in computer-aided design-computer-aided manufacturing (CAD-CAM) blocks have been associated with new polymerization modes, innovative microstructures, and different compositions. All these recent breakthroughs have introduced important gaps among the properties of the different materials. This critical state-of-the-art review analyzes the strengths and weaknesses of the different varieties of CAD-CAM composite materials, especially as compared with direct and artisanal indirect composites. Indeed, new polymerization modes used for CAD-CAM blocks-especially high temperature (HT) and, most of all, high temperature-high pressure (HT-HP)-are shown to significantly increase the degree of conversion in comparison with light-cured composites. Industrial processes also allow for the augmentation of the filler content and for the realization of more homogeneous structures with fewer flaws. In addition, due to their increased degree of conversion and their different monomer composition, some CAD-CAM blocks are more advantageous in terms of toxicity and monomer release. Finally, materials with a polymer-infiltrated ceramic network (PICN) microstructure exhibit higher flexural strength and a more favorable elasticity modulus than materials with a dispersed filler microstructure. Consequently, some high-performance composite CAD-CAM blocks-particularly experimental PICNs-can now rival glass-ceramics, such as lithium-disilicate glass-ceramics, for use as bonded partial restorations and crowns on natural teeth and implants. Being able to be manufactured in very low thicknesses, they offer the possibility of developing innovative minimally invasive treatment strategies, such as "no prep" treatment of worn dentition. Current issues are related to the study of bonding and wear properties of the different varieties of CAD-CAM composites. There is also a crucial need to conduct clinical studies. Last, manufacturers should provide more complete information regarding their product polymerization process, microstructure, and composition, which significantly influence CAD-CAM material properties. © International & American Associations for Dental Research 2016.

  16. Effect of surface treatments on the bond strength of CAD/CAM fiberglass posts.

    PubMed

    Garcia, Paula-Pontes; da Costa, Rogério-Goulart; Garcia, André-Vivan; Gonzaga, Carla-Castiglia; da Cunha, Leonardo-Fernandes; Rezende, Carlos-Eduardo-Edwards; Correr, Gisele-Maria

    2018-06-01

    There is no ideal protocol for the surface treatment of fiber posts, especially when using a computer-aided design/computer-aided manufacturing (CAD/CAM) experimental fiberglass block. The purpose of this study was to evaluate the bond strength of a CAD/CAM customized glass fiber post and core after applying different surface treatment techniques. Forty premolars were prepared to receive a customized CAD/CAM glass-fiber post and core obtained from an experimental block of glass fiber and epoxy resin. The specimens were randomly distributed in 4 groups (n=10) according to the post and core surface treatment: ETH - 70% ethanol; HP - 24% hydrogen peroxide for 1 minute; ETH/S - 70% ethanol + silane; HP/S - 24% hydrogen peroxide + silane. The universal adhesive containing silane was applied on the posts and prepared post spaces in all groups. The posts were cemented using dual cure resin cement. The specimens were stored in distilled water at 37°C for 24 h, cut (two slices of 1 mm for each root third - coronal, middle, and apical) and subjected to push-out test (0.5 mm/min). Data was subjected to two-way ANOVA (surface treatment and root third) and Tukey's test (α=0,05). There was no significant difference of bond strength values among groups, regardless the surface treatment ( p >0.05). There was significant difference on bond strength values for the different root thirds ( p <0.05) (coronal>middle=apical). The different surface treatment and application of additional silane in the CAD/CAM customized glass-fiber post and core does not interfere on bond strength values. The root dentin third interfered on the bond strength, with higher values for the coronal third. Key words: Post and core technique, cad/cam, shear strength, hydrogen peroxide.

  17. CMU/IBM Usability Study: Final Report. CDC Technical Report No. 11.

    ERIC Educational Resources Information Center

    Ballay, Joseph M.; And Others

    This report focuses on the activities and findings of the fourth phase of research carried out at Carnegie-Mellon University (CMU) on the development of user documentation for computer-aided design (CAD) systems. The first of four major sections provides an overview of recent research, issues involved in the research, and implications of the…

  18. MSIX - A general and user-friendly platform for RAM analysis

    NASA Astrophysics Data System (ADS)

    Pan, Z. J.; Blemel, Peter

    The authors present a CAD (computer-aided design) platform supporting RAM (reliability, availability, and maintainability) analysis with efficient system description and alternative evaluation. The design concepts, implementation techniques, and application results are described. This platform is user-friendly because of its graphic environment, drawing facilities, object orientation, self-tutoring, and access to the operating system. The programs' independency and portability make them generally applicable to various analysis tasks.

  19. Accurate reconstruction of discontinuous mandible using a reverse engineering/computer-aided design/rapid prototyping technique: a preliminary clinical study.

    PubMed

    Zhou, Li-bin; Shang, Hong-tao; He, Li-sheng; Bo, Bin; Liu, Gui-cai; Liu, Yan-pu; Zhao, Jin-long

    2010-09-01

    To improve the reconstructive surgical outcome of a discontinuous mandibular defect, we used reverse engineering (RE), computer-aided design (CAD), and rapid prototyping (RP) technique to fabricate customized mandibular trays to precisely restore the mandibular defects. Autogenous bone grafting was also used to restore the bony continuity for occlusion rehabilitation. Six patients who had undergone block resection of the mandible underwent reconstruction using a custom titanium tray combining autogenous iliac grafts. The custom titanium tray was made using a RE/CAD/RP technique. A virtual 3-dimensional model was obtained by spiral computed tomography scanning. The opposite side of the mandible was mirrored to cover the defect area to restore excellent facial symmetry. A bone grafting tray was designed from the mirrored image and manufactured using RP processing and casting. The mandibular defects were restored using the trays in combination of autologous iliac grafting. An implant denture was made for 1 of the 6 patients at 24 weeks postoperatively for occlusion rehabilitation. The trays fabricated using this technique fit well in all 6 patients. The reconstructive procedures were easy and time saving. Satisfactory facial symmetry was restored. No severe complications occurred in the 5 patients without occlusion rehabilitation during a mean 50-month follow-up period. The reconstruction in the patient with occlusion lasted for only 1 year and failed eventually because of bone resorption and infection. Mandibular reconstruction was facilitated using the RE/CAD/RP technique. Satisfactory esthetic results were achieved. However, the rigidity of the cast tray could cause severe stress shielding to the grafts, which could lead to disuse atrophy. Therefore, some modification is needed for functional reconstruction. Copyright 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  20. An interactive system for computer-aided diagnosis of breast masses.

    PubMed

    Wang, Xingwei; Li, Lihua; Liu, Wei; Xu, Weidong; Lederman, Dror; Zheng, Bin

    2012-10-01

    Although mammography is the only clinically accepted imaging modality for screening the general population to detect breast cancer, interpreting mammograms is difficult with lower sensitivity and specificity. To provide radiologists "a visual aid" in interpreting mammograms, we developed and tested an interactive system for computer-aided detection and diagnosis (CAD) of mass-like cancers. Using this system, an observer can view CAD-cued mass regions depicted on one image and then query any suspicious regions (either cued or not cued by CAD). CAD scheme automatically segments the suspicious region or accepts manually defined region and computes a set of image features. Using content-based image retrieval (CBIR) algorithm, CAD searches for a set of reference images depicting "abnormalities" similar to the queried region. Based on image retrieval results and a decision algorithm, a classification score is assigned to the queried region. In this study, a reference database with 1,800 malignant mass regions and 1,800 benign and CAD-generated false-positive regions was used. A modified CBIR algorithm with a new function of stretching the attributes in the multi-dimensional space and decision scheme was optimized using a genetic algorithm. Using a leave-one-out testing method to classify suspicious mass regions, we compared the classification performance using two CBIR algorithms with either equally weighted or optimally stretched attributes. Using the modified CBIR algorithm, the area under receiver operating characteristic curve was significantly increased from 0.865 ± 0.006 to 0.897 ± 0.005 (p < 0.001). This study demonstrated the feasibility of developing an interactive CAD system with a large reference database and achieving improved performance.

  1. Computer-Aided Diagnosis for Breast Ultrasound Using Computerized BI-RADS Features and Machine Learning Methods.

    PubMed

    Shan, Juan; Alam, S Kaisar; Garra, Brian; Zhang, Yingtao; Ahmed, Tahira

    2016-04-01

    This work identifies effective computable features from the Breast Imaging Reporting and Data System (BI-RADS), to develop a computer-aided diagnosis (CAD) system for breast ultrasound. Computerized features corresponding to ultrasound BI-RADs categories were designed and tested using a database of 283 pathology-proven benign and malignant lesions. Features were selected based on classification performance using a "bottom-up" approach for different machine learning methods, including decision tree, artificial neural network, random forest and support vector machine. Using 10-fold cross-validation on the database of 283 cases, the highest area under the receiver operating characteristic (ROC) curve (AUC) was 0.84 from a support vector machine with 77.7% overall accuracy; the highest overall accuracy, 78.5%, was from a random forest with the AUC 0.83. Lesion margin and orientation were optimum features common to all of the different machine learning methods. These features can be used in CAD systems to help distinguish benign from worrisome lesions. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. All rights reserved.

  2. A CAD System for Hemorrhagic Stroke.

    PubMed

    Nowinski, Wieslaw L; Qian, Guoyu; Hanley, Daniel F

    2014-09-01

    Computer-aided detection/diagnosis (CAD) is a key component of routine clinical practice, increasingly used for detection, interpretation, quantification and decision support. Despite a critical need, there is no clinically accepted CAD system for stroke yet. Here we introduce a CAD system for hemorrhagic stroke. This CAD system segments, quantifies, and displays hematoma in 2D/3D, and supports evacuation of hemorrhage by thrombolytic treatment monitoring progression and quantifying clot removal. It supports seven-step workflow: select patient, add a new study, process patient's scans, show segmentation results, plot hematoma volumes, show 3D synchronized time series hematomas, and generate report. The system architecture contains four components: library, tools, application with user interface, and hematoma segmentation algorithm. The tools include a contour editor, 3D surface modeler, 3D volume measure, histogramming, hematoma volume plot, and 3D synchronized time-series hematoma display. The CAD system has been designed and implemented in C++. It has also been employed in the CLEAR and MISTIE phase-III, multicenter clinical trials. This stroke CAD system is potentially useful in research and clinical applications, particularly for clinical trials.

  3. Machine Tool Software

    NASA Technical Reports Server (NTRS)

    1988-01-01

    A NASA-developed software package has played a part in technical education of students who major in Mechanical Engineering Technology at William Rainey Harper College. Professor Hack has been using (APT) Automatically Programmed Tool Software since 1969 in his CAD/CAM Computer Aided Design and Manufacturing curriculum. Professor Hack teaches the use of APT programming languages for control of metal cutting machines. Machine tool instructions are geometry definitions written in APT Language to constitute a "part program." The part program is processed by the machine tool. CAD/CAM students go from writing a program to cutting steel in the course of a semester.

  4. Denver RTD's computer aided dispatch/automatic vehicle location system : the human factors consequences

    DOT National Transportation Integrated Search

    1999-09-01

    This report documents what happened to employees' work procedures when their employer when their employer installed Computer Aided Disptach/Automatic Vehicle Locator (CAD/AVL) technology to provide real-time surveillance of vehicles and to upgrade ra...

  5. Custom hip prostheses by integrating CAD and casting technology

    NASA Astrophysics Data System (ADS)

    Silva, Pedro F.; Leal, Nuno; Neto, Rui J.; Lino, F. Jorge; Reis, Ana

    2012-09-01

    Total Hip Arthroplasty (THA) is a surgical intervention that is being achieving high rates of success, leaving room to research on long run durability, patient comfort and costs reduction. Even so, up to the present, little research has been done to improve the method of manufacturing customized prosthesis. The common customized prostheses are made by full machining. This document presents a different approach methodology which combines the study of medical images, through CAD (Computer Aided Design) software, SLadditive manufacturing, ceramic shell manufacture, precision foundry with Titanium alloys and Computer Aided Manufacturing (CAM). The goal is to achieve the best comfort for the patient, stress distribution and the maximum lifetime of the prosthesis produced by this integrated methodology. The way to achieve this desiderate is to make custom hip prosthesis which are adapted to each patient needs and natural physiognomy. Not only the process is reliable, but also represents a cost reduction comparing to the conventional full machined custom hip prosthesis.

  6. Fracture behavior of metal-ceramic fixed dental prostheses with frameworks from cast or a newly developed sintered cobalt-chromium alloy.

    PubMed

    Krug, Klaus-Peter; Knauber, Andreas W; Nothdurft, Frank P

    2015-03-01

    The aim of this study was to investigate the fracture behavior of metal-ceramic bridges with frameworks from cobalt-chromium-molybdenum (CoCrMo), which are manufactured using conventional casting or a new computer-aided design/computer-aided manufacturing (CAD/CAM) milling and sintering technique. A total of 32 metal-ceramic fixed dental prostheses (FDPs), which are based on a nonprecious metal framework, was produced using a conventional casting process (n = 16) or a new CAD/CAM milling and sintering process (n = 16). Eight unveneered frameworks were manufactured using each of the techniques. After thermal and mechanical aging of half of the restorations, all samples were subjected to a static loading test in a universal testing machine, in which acoustic emission monitoring was performed. Three different critical forces were revealed: the fracture force (F max), the force at the first reduction in force (F decr1), and the force at the critical acoustic event (F acoust1). With the exception of the veneered restorations with cast or sintered metal frameworks without artificial aging, which presented a statistically significant but slightly different F max, no statistically significant differences between cast and CAD/CAM sintered and milled FDPs were detected. Thermal and mechanical loading did not significantly affect the resulting forces. Cast and CAD/CAM milled and sintered metal-ceramic bridges were determined to be comparable with respect to the fracture behavior. FDPs based on CAD/CAM milled and sintered frameworks may be an applicable and less technique-sensitive alternative to frameworks that are based on conventionally cast frameworks.

  7. When and why might a Computer Aided Detection (CAD) system interfere with visual search? An eye-tracking study

    PubMed Central

    Drew, Trafton; Cunningham, Corbin; Wolfe, Jeremy

    2012-01-01

    Rational and Objectives Computer Aided Detection (CAD) systems are intended to improve performance. This study investigates how CAD might actually interfere with a visual search task. This is a laboratory study with implications for clinical use of CAD. Methods 47 naïve observers in two studies were asked to search for a target, embedded in 1/f2.4 noise while we monitored their eye-movements. For some observers, a CAD system marked 75% of targets and 10% of distractors while other observers completed the study without CAD. In Experiment 1, the CAD system’s primary function was to tell observers where the target might be. In Experiment 2, CAD provided information about target identity. Results In Experiment 1, there was a significant enhancement of observer sensitivity in the presence of CAD (t(22)=4.74, p<.001), but there was also a substantial cost. Targets that were not marked by the CAD system were missed more frequently than equivalent targets in No CAD blocks of the experiment (t(22)=7.02, p<.001). Experiment 2 showed no behavioral benefit from CAD, but also no significant cost on sensitivity to unmarked targets (t(22)=0.6, p=n.s.). Finally, in both experiments, CAD produced reliable changes in eye-movements: CAD observers examined a lower total percentage of the search area than the No CAD observers (Ex 1: t(48)=3.05, p<.005; Ex 2: t(50)=7.31, p<.001). Conclusions CAD signals do not combine with observers’ unaided performance in a straight-forward manner. CAD can engender a sense of certainty that can lead to incomplete search and elevated chances of missing unmarked stimuli. PMID:22958720

  8. New protocol for construction of eyeglasses-supported provisional nasal prosthesis using CAD/CAM techniques.

    PubMed

    Ciocca, Leonardo; Fantini, Massimiliano; De Crescenzio, Francesca; Persiani, Franco; Scotti, Roberto

    2010-01-01

    A new protocol for making an immediate provisional eyeglasses-supported nasal prosthesis is presented that uses laser scanning, computer-aided design/computer-aided manufacturing procedures, and rapid prototyping techniques, reducing time and costs while increasing the quality of the final product. With this protocol, the eyeglasses were digitized, and the relative position of the nasal prosthesis was planned and evaluated in a virtual environment without any try-in appointment. This innovative method saves time, reduces costs, and restores the patient's aesthetic appearance after a disfiguration caused by ablation of the nasal pyramid better than conventional restoration methods. Moreover, the digital model of the designed nasal epithesis can be used to develop a definitive prosthesis anchored to osseointegrated craniofacial implants.

  9. Precise Reproduction of Soft Tissue Structure around the Pontic Area Using Computer-Aided Design and Manufacturing.

    PubMed

    Lee, Hyeonjong; Paek, Janghyun; Noh, Kwantae; Kwon, Kung-Rock

    2017-08-21

    Reproducing soft tissue contours around a pontic area is important for the fabrication of an esthetic prosthesis, especially in the anterior area. A gingival model that precisely replicates the soft tissue structure around the pontic area can be easily obtained by taking a pick-up impression of an interim fixed dental prosthesis. After a working cast is fabricated using the customary technique, the pick-up model is superimposed onto the working model for the pontic area using computer-aided design and manufacturing (CAD/CAM). A definitive restoration using this technique would be well adapted to the pontic base, which is formed by the interim prosthesis. © 2017 by the American College of Prosthodontists.

  10. Scanning Electron Microscopy Analysis of the Adaptation of Single-Unit Screw-Retained Computer-Aided Design/Computer-Aided Manufacture Abutments After Mechanical Cycling.

    PubMed

    Markarian, Roberto Adrian; Galles, Deborah Pedroso; Gomes França, Fabiana Mantovani

    To measure the microgap between dental implants and custom abutments fabricated using different computer-aided design/computer-aided manufacture (CAD/CAM) methods before and after mechanical cycling. CAD software (Dental System, 3Shape) was used to design a custom abutment for a single-unit, screw-retained crown compatible with a 4.1-mm external hexagon dental implant. The resulting stereolithography file was sent for manufacturing using four CAD/CAM methods (n = 40): milling and sintering of zirconium dioxide (ZO group), cobalt-chromium (Co-Cr) sintered via selective laser melting (SLM group), fully sintered machined Co-Cr alloy (MM group), and machined and sintered agglutinated Co-Cr alloy powder (AM group). Prefabricated titanium abutments (TI group) were used as controls. Each abutment was placed on a dental implant measuring 4.1× 11 mm (SA411, SIN) inserted into an aluminum block. Measurements were taken using scanning electron microscopy (SEM) (×4,000) on four regions of the implant-abutment interface (IAI) and at a relative distance of 90 degrees from each other. The specimens were mechanically aged (1 million cycles, 2 Hz, 100 N, 37°C) and the IAI width was measured again using the same approach. Data were analyzed using two-way analysis of variance, followed by the Tukey test. After mechanical cycling, the best adaptation results were obtained from the TI (2.29 ± 1.13 μm), AM (3.58 ± 1.80 μm), and MM (1.89 ± 0.98 μm) groups. A significantly worse adaptation outcome was observed for the SLM (18.40 ± 20.78 μm) and ZO (10.42 ± 0.80 μm) groups. Mechanical cycling had a marked effect only on the AM specimens, which significantly increased the microgap at the IAI. Custom abutments fabricated using fully sintered machined Co-Cr alloy and machined and sintered agglutinated Co-Cr alloy powder demonstrated the best adaptation results at the IAI, similar to those obtained with commercial prefabricated titanium abutments after mechanical cycling. The adaptation of custom abutments made by means of SLM or milling and sintering of zirconium dioxide were worse both before and after mechanical cycling.

  11. Current And Future Directions Of Lens Design Software

    NASA Astrophysics Data System (ADS)

    Gustafson, Darryl E.

    1983-10-01

    The most effective environment for doing lens design continues to evolve as new computer hardware and software tools become available. Important recent hardware developments include: Low-cost but powerful interactive multi-user 32 bit computers with virtual memory that are totally software-compatible with prior larger and more expensive members of the family. A rapidly growing variety of graphics devices for both hard-copy and screen graphics, including many with color capability. In addition, with optical design software readily accessible in many forms, optical design has become a part-time activity for a large number of engineers instead of being restricted to a small number of full-time specialists. A designer interface that is friendly for the part-time user while remaining efficient for the full-time designer is thus becoming more important as well as more practical. Along with these developments, software tools in other scientific and engineering disciplines are proliferating. Thus, the optical designer is less and less unique in his use of computer-aided techniques and faces the challenge and opportunity of efficiently communicating his designs to other computer-aided-design (CAD), computer-aided-manufacturing (CAM), structural, thermal, and mechanical software tools. This paper will address the impact of these developments on the current and future directions of the CODE VTM optical design software package, its implementation, and the resulting lens design environment.

  12. Effect of Endocrown Restorations with Different CAD/CAM Materials: 3D Finite Element and Weibull Analyses

    PubMed Central

    Ulusoy, Nuran

    2017-01-01

    The aim of this study was to evaluate the effects of two endocrown designs and computer aided design/manufacturing (CAD/CAM) materials on stress distribution and failure probability of restorations applied to severely damaged endodontically treated maxillary first premolar tooth (MFP). Two types of designs without and with 3 mm intraradicular extensions, endocrown (E) and modified endocrown (ME), were modeled on a 3D Finite element (FE) model of the MFP. Vitablocks Mark II (VMII), Vita Enamic (VE), and Lava Ultimate (LU) CAD/CAM materials were used for each type of design. von Mises and maximum principle values were evaluated and the Weibull function was incorporated with FE analysis to calculate the long term failure probability. Regarding the stresses that occurred in enamel, for each group of material, ME restoration design transmitted less stress than endocrown. During normal occlusal function, the overall failure probability was minimum for ME with VMII. ME restoration design with VE was the best restorative option for premolar teeth with extensive loss of coronal structure under high occlusal loads. Therefore, ME design could be a favorable treatment option for MFPs with missing palatal cusp. Among the CAD/CAM materials tested, VMII and VE were found to be more tooth-friendly than LU. PMID:29119108

  13. IPAD II (Integrated Programs for Aerospace-Vehicle Design) Advances in Distributed Data Base Management for CAD/CAM (Computer-Aided Design and Manufacturing Technology). Proceedings of a National Symposium Held in Denver, Colorado, April 17-19, 1984.

    DTIC Science & Technology

    1984-01-01

    working drawings, lists, and miscellaneous information needed for construction and testing (fig. 4). Detail design and construction in- cludes...still in test and evaluation phases, and is currently operational on a CDC computer. Its approach to management of geometric data is a unique and...been to provide the high degree of engineering user flexibility and yet achieve acceptable response times. In late 1983, a test system which has user

  14. A new semiquantitative method for evaluation of metastasis progression.

    PubMed

    Volarevic, A; Ljujic, B; Volarevic, V; Milovanovic, M; Kanjevac, T; Lukic, A; Arsenijevic, N

    2012-01-01

    Although recent technical advancements are directed toward developing novel assays and methods for detection of micro and macro metastasis, there are still no reports of reliable, simple to use imaging software that could be used for the detection and quantification of metastasis in tissue sections. We herein report a new semiquantitative method for evaluation of metastasis progression in a well established 4T1 orthotopic mouse model of breast cancer metastasis. The new semiquantitative method presented here was implemented by using the Autodesk AutoCAD 2012 program, a computer-aided design program used primarily for preparing technical drawings in 2 dimensions. By using the Autodesk AutoCAD 2012 software- aided graphical evaluation we managed to detect each metastatic lesion and we precisely calculated the average percentage of lung and liver tissue parenchyma with metastasis in 4T1 tumor-bearing mice. The data were highly specific and relevant to descriptive histological analysis, confirming reliability and accuracy of the AutoCAD 2012 software as new method for quantification of metastatic lesions. The new semiquantitative method using AutoCAD 2012 software provides a novel approach for the estimation of metastatic progression in histological tissue sections.

  15. Theoretical Design of Multilayer Dental Posts Using CAD-Based Approach and Sol-Gel Chemistry.

    PubMed

    Maietta, Saverio; De Santis, Roberto; Catauro, Michelina; Martorelli, Massimo; Gloria, Antonio

    2018-05-07

    A computer-aided design (CAD)-based approach and sol-gel chemistry were used to design a multilayer dental post with a compositional gradient and a Young’s modulus varying from 12.4 to 2.3 GPa in the coronal-apical direction. Specifically, we propose a theoretical multilayer post design, consisting of titanium dioxide (TiO₂) and TiO₂/poly(ε-caprolactone) (PCL) hybrid materials containing PCL up to 24% by weight obtained using the sol-gel method. The current study aimed to analyze the effect of the designed multilayer dental post in endodontically treated anterior teeth. Stress distribution was investigated along and between the post and the surrounding structures. In comparison to a metal post, the most uniform distributions with lower stress values and no significant stress concentration were found when using the multilayer post.

  16. The smiling scan technique: Facially driven guided surgery and prosthetics.

    PubMed

    Pozzi, Alessandro; Arcuri, Lorenzo; Moy, Peter K

    2018-04-11

    To introduce a proof of concept technique and new integrated workflow to optimize the functional and esthetic outcome of the implant-supported restorations by means of a 3-dimensional (3D) facially-driven, digital assisted treatment plan. The Smiling Scan technique permits the creation of a virtual dental patient (VDP) showing a broad smile under static conditions. The patient is exposed to a cone beam computed tomography scan (CBCT), displaying a broad smile for the duration of the examination. Intraoral optical surface scanning (IOS) of the dental and soft tissue anatomy or extraoral optical surface scanning (EOS) of the study casts are achieved. The superimposition of the digital imaging and communications in medicine (DICOM) files with standard tessellation language (STL) files is performed using the virtual planning software program permitting the creation of a VDP. The smiling scan is an effective, easy to use, and low-cost technique to develop a more comprehensive and simplified facially driven computer-assisted treatment plan, allowing a prosthetically driven implant placement and the delivery of an immediate computer aided design (CAD) computer aided manufacturing (CAM) temporary fixed dental prostheses (CAD/CAM technology). Copyright © 2018 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  17. Design Through Manufacturing: The Solid Model - Finite Element Analysis Interface

    NASA Technical Reports Server (NTRS)

    Rubin, Carol

    2003-01-01

    State-of-the-art computer aided design (CAD) presently affords engineers the opportunity to create solid models of machine parts which reflect every detail of the finished product. Ideally, these models should fulfill two very important functions: (1) they must provide numerical control information for automated manufacturing of precision parts, and (2) they must enable analysts to easily evaluate the stress levels (using finite element analysis - FEA) for all structurally significant parts used in space missions. Today's state-of-the-art CAD programs perform function (1) very well, providing an excellent model for precision manufacturing. But they do not provide a straightforward and simple means of automating the translation from CAD to FEA models, especially for aircraft-type structures. The research performed during the fellowship period investigated the transition process from the solid CAD model to the FEA stress analysis model with the final goal of creating an automatic interface between the two. During the period of the fellowship a detailed multi-year program for the development of such an interface was created. The ultimate goal of this program will be the development of a fully parameterized automatic ProE/FEA translator for parts and assemblies, with the incorporation of data base management into the solution, and ultimately including computational fluid dynamics and thermal modeling in the interface.

  18. Improved cancer detection in automated breast ultrasound by radiologists using Computer Aided Detection.

    PubMed

    van Zelst, J C M; Tan, T; Platel, B; de Jong, M; Steenbakkers, A; Mourits, M; Grivegnee, A; Borelli, C; Karssemeijer, N; Mann, R M

    2017-04-01

    To investigate the effect of dedicated Computer Aided Detection (CAD) software for automated breast ultrasound (ABUS) on the performance of radiologists screening for breast cancer. 90 ABUS views of 90 patients were randomly selected from a multi-institutional archive of cases collected between 2010 and 2013. This dataset included normal cases (n=40) with >1year of follow up, benign (n=30) lesions that were either biopsied or remained stable, and malignant lesions (n=20). Six readers evaluated all cases with and without CAD in two sessions. CAD-software included conventional CAD-marks and an intelligent minimum intensity projection of the breast tissue. Readers reported using a likelihood-of-malignancy scale from 0 to 100. Alternative free-response ROC analysis was used to measure the performance. Without CAD, the average area-under-the-curve (AUC) of the readers was 0.77 and significantly improved with CAD to 0.84 (p=0.001). Sensitivity of all readers improved (range 5.2-10.6%) by using CAD but specificity decreased in four out of six readers (range 1.4-5.7%). No significant difference was observed in the AUC between experienced radiologists and residents both with and without CAD. Dedicated CAD-software for ABUS has the potential to improve the cancer detection rates of radiologists screening for breast cancer. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Accelerating orthodontic tooth movement: A new, minimally-invasive corticotomy technique using a 3D-printed surgical template.

    PubMed

    Cassetta, M; Giansanti, M

    2016-07-01

    A reduction in orthodontic treatment time can be attained using corticotomies. The aggressive nature of corticotomy due to the elevation of muco-periosteal flaps and to the duration of the surgery raised reluctance for its employ among patients and dental community. This study aims to provide detailed information on the design and manufacture of a 3D-printed CAD-CAM (computer-aided design and computer-aided manufacturing) surgical guide which can aid the clinician in achieving a minimally-invasive, flapless corticotomy. An impression of dental arches was created; the models were digitally-acquired using a 3D scanner and saved as STereoLithography ( STL ) files. The patient underwent cone beam computed tomography (CBCT): images of jaws and teeth were transformed into 3D models and saved as an STL file. An acrylic template with the design of a surgical guide was manufactured and scanned. The STLs of jaws, scanned casts, and acrylic templates were matched. 3D modeling software allowed the view of the 3D models from different perspectives and planes with perfect rendering. The 3D model of the acrylic template was transformed into a surgical guide with slots designed to guide, at first, a scalpel blade and then a piezoelectric cutting insert. The 3D STL model of the surgical guide was printed. This procedure allowed the manufacturing of a 3D-printed CAD/CAM surgical guide, which overcomes the disadvantages of the corticotomy, removing the need for flap elevation. No discomfort, early surgical complications or unexpected events were observed. The effectiveness of this minimally-invasive surgical technique can offer the clinician a valid alternative to other methods currently in use.

  20. Digital impression and jaw relation record for the fabrication of CAD/CAM custom tray.

    PubMed

    Kanazawa, Manabu; Iwaki, Maiko; Arakida, Toshio; Minakuchi, Shunsuke

    2018-03-16

    This article describes the protocol of a digital impression technique to make an impression and recording of the jaw relationship of edentulous patients for the fabrication of CAD/CAM custom tray using computer-aided design and manufacturing (CAD/CAM) technology. Scan the maxillary and mandibular edentulous jaws using an intraoral scanner. Scan the silicone jig with the maxillary and mandibular jaws while keeping the jig between the jaws. Import the standard tessellation language data of the maxillary and mandibular jaws and jig to make a jaw relation record and fabricate custom trays (CAD/CAM trays) using a rapid prototyping system. Make a definitive impression of the maxillary and mandibular jaws using the CAD/CAM trays. Digitalization of the complete denture fabrication process can simplify the complicated treatment and laboratory process of conventional methods In addition, the proposed method enables quality control regardless of the operator's experience and technique. Copyright © 2018. Published by Elsevier Ltd.

  1. Comparing two types of engineering visualizations: task-related manipulations matter.

    PubMed

    Cölln, Martin C; Kusch, Kerstin; Helmert, Jens R; Kohler, Petra; Velichkovsky, Boris M; Pannasch, Sebastian

    2012-01-01

    This study focuses on the comparison of traditional engineering drawings with a CAD (computer aided design) visualization in terms of user performance and eye movements in an applied context. Twenty-five students of mechanical engineering completed search tasks for measures in two distinct depictions of a car engine component (engineering drawing vs. CAD model). Besides spatial dimensionality, the display types most notably differed in terms of information layout, access and interaction options. The CAD visualization yielded better performance, if users directly manipulated the object, but was inferior, if employed in a conventional static manner, i.e. inspecting only predefined views. An additional eye movement analysis revealed longer fixation durations and a stronger increase of task-relevant fixations over time when interacting with the CAD visualization. This suggests a more focused extraction and filtering of information. We conclude that the three-dimensional CAD visualization can be advantageous if its ability to manipulate is used. Copyright © 2011 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  2. Evaluation of computer-aided diagnosis (CAD) software for the detection of lung nodules on multidetector row computed tomography (MDCT): JAFROC study for the improvement in radiologists' diagnostic accuracy.

    PubMed

    Hirose, Tomohiro; Nitta, Norihisa; Shiraishi, Junji; Nagatani, Yukihiro; Takahashi, Masashi; Murata, Kiyoshi

    2008-12-01

    The aim of this study was to evaluate the usefulness of computer-aided diagnosis (CAD) software for the detection of lung nodules on multidetector-row computed tomography (MDCT) in terms of improvement in radiologists' diagnostic accuracy in detecting lung nodules, using jackknife free-response receiver-operating characteristic (JAFROC) analysis. Twenty-one patients (6 without and 15 with lung nodules) were selected randomly from 120 consecutive thoracic computed tomographic examinations. The gold standard for the presence or absence of nodules in the observer study was determined by consensus of two radiologists. Six expert radiologists participated in a free-response receiver operating characteristic study for the detection of lung nodules on MDCT, in which cases were interpreted first without and then with the output of CAD software. Radiologists were asked to indicate the locations of lung nodule candidates on the monitor with their confidence ratings for the presence of lung nodules. The performance of the CAD software indicated that the sensitivity in detecting lung nodules was 71.4%, with 0.95 false-positive results per case. When radiologists used the CAD software, the average sensitivity improved from 39.5% to 81.0%, with an increase in the average number of false-positive results from 0.14 to 0.89 per case. The average figure-of-merit values for the six radiologists were 0.390 without and 0.845 with the output of the CAD software, and there was a statistically significant difference (P < .0001) using the JAFROC analysis. The CAD software for the detection of lung nodules on MDCT has the potential to assist radiologists by increasing their accuracy.

  3. Endodontic applications of 3D printing.

    PubMed

    Anderson, J; Wealleans, J; Ray, J

    2018-02-27

    Computer-aided design (CAD) and computer-aided manufacturing (CAM) technologies can leverage cone beam computed tomography data for production of objects used in surgical and nonsurgical endodontics and in educational settings. The aim of this article was to review all current applications of 3D printing in endodontics and to speculate upon future directions for research and clinical use within the specialty. A literature search of PubMed, Ovid and Scopus was conducted using the following terms: stereolithography, 3D printing, computer aided rapid prototyping, surgical guide, guided endodontic surgery, guided endodontic access, additive manufacturing, rapid prototyping, autotransplantation rapid prototyping, CAD, CAM. Inclusion criteria were articles in the English language documenting endodontic applications of 3D printing. Fifty-one articles met inclusion criteria and were utilized. The endodontic literature on 3D printing is generally limited to case reports and pre-clinical studies. Documented solutions to endodontic challenges include: guided access with pulp canal obliteration, applications in autotransplantation, pre-surgical planning and educational modelling and accurate location of osteotomy perforation sites. Acquisition of technical expertise and equipment within endodontic practices present formidable obstacles to widespread deployment within the endodontic specialty. As knowledge advances, endodontic postgraduate programmes should consider implementing 3D printing into their curriculums. Future research directions should include clinical outcomes assessments of treatments employing 3D printed objects. Published 2018. This article is a U.S. Government work and is in the public domain in the USA.

  4. AUTOMATING THREE DIMENSIONAL (3D) MODEL CREATION OF CIRCUIT CARD ASSEMBLIES

    DTIC Science & Technology

    2017-07-01

    are those of the author(s) and should not be construed as an official Department of the Army position, policy, or decision, unless so designated by...other documentation. The citation in this report of the names of commercial firms or commercially available products or services does not...document describes a method to export data from a printed wiring board computer-aided design (CAD) application and then import that data to a

  5. Computer-Aided Diagnosis System for Alzheimer's Disease Using Different Discrete Transform Techniques.

    PubMed

    Dessouky, Mohamed M; Elrashidy, Mohamed A; Taha, Taha E; Abdelkader, Hatem M

    2016-05-01

    The different discrete transform techniques such as discrete cosine transform (DCT), discrete sine transform (DST), discrete wavelet transform (DWT), and mel-scale frequency cepstral coefficients (MFCCs) are powerful feature extraction techniques. This article presents a proposed computer-aided diagnosis (CAD) system for extracting the most effective and significant features of Alzheimer's disease (AD) using these different discrete transform techniques and MFCC techniques. Linear support vector machine has been used as a classifier in this article. Experimental results conclude that the proposed CAD system using MFCC technique for AD recognition has a great improvement for the system performance with small number of significant extracted features, as compared with the CAD system based on DCT, DST, DWT, and the hybrid combination methods of the different transform techniques. © The Author(s) 2015.

  6. 3D Displays And User Interface Design For A Radiation Therapy Treatment Planning CAD Tool

    NASA Astrophysics Data System (ADS)

    Mosher, Charles E.; Sherouse, George W.; Chaney, Edward L.; Rosenman, Julian G.

    1988-06-01

    The long term goal of the project described in this paper is to improve local tumor control through the use of computer-aided treatment design methods that can result in selection of better treatment plans compared with conventional planning methods. To this end, a CAD tool for the design of radiation treatment beams is described. Crucial to the effectiveness of this tool are high quality 3D display techniques. We have found that 2D and 3D display methods dramatically improve the comprehension of the complex spatial relationships between patient anatomy, radiation beams, and dose distributions. In order to take full advantage of these displays, an intuitive and highly interactive user interface was created. If the system is to be used by physicians unfamiliar with computer systems, it is essential that a user interface is incorporated that allows the user to navigate through each step of the design process in a manner similar to what they are used to. Compared with conventional systems, we believe our display and CAD tools will allow the radiotherapist to achieve more accurate beam targetting leading to a better radiation dose configuration to the tumor volume. This would result in a reduction of the dose to normal tissue.

  7. Use of Parallel Micro-Platform for the Simulation the Space Exploration

    NASA Astrophysics Data System (ADS)

    Velasco Herrera, Victor Manuel; Velasco Herrera, Graciela; Rosano, Felipe Lara; Rodriguez Lozano, Salvador; Lucero Roldan Serrato, Karen

    The purpose of this work is to create a parallel micro-platform, that simulates the virtual movements of a space exploration in 3D. One of the innovations presented in this design consists of the application of a lever mechanism for the transmission of the movement. The development of such a robot is a challenging task very different of the industrial manipulators due to a totally different target system of requirements. This work presents the study and simulation, aided by computer, of the movement of this parallel manipulator. The development of this model has been developed using the platform of computer aided design Unigraphics, in which it was done the geometric modeled of each one of the components and end assembly (CAD), the generation of files for the computer aided manufacture (CAM) of each one of the pieces and the kinematics simulation of the system evaluating different driving schemes. We used the toolbox (MATLAB) of aerospace and create an adaptive control module to simulate the system.

  8. An approach to biomimetics: the natural CAD/CAM restoration: a clinical report.

    PubMed

    Schlichting, Luís Henrique; Schlichting, Kathryn Klemz; Stanley, Kyle; Magne, Michel; Magne, Pascal

    2014-02-01

    Those in the dental field have always pursued the perfect dental material for the treatment of compromised teeth. Gold, amalgam, composite resin, glass ionomer, and porcelain have been used. Tooth-like restorative materials (composite resin and porcelain) combined with an effective hard tissue bond have met the growing demand for esthetic or metal-free restorations in the past 15 to 20 years. However, none of those materials can fully mimic the unique properties of dentin (compliance and crack-stopping behavior) and enamel (wear resistance, function). The aim of this article is to report the restoration of an extensively damaged tooth with a natural restoration obtained by milling an extracted third molar tooth with a computer-aided design and computer-aided manufacturing (CAD/CAM) system. The main benefit of this novel technique is the replacement of lost tissues by actual enamel and dentin, with the potential to recover mechanical, esthetic, and biologic properties. The indication for extracting third molars and premolars because of impaction or for orthodontic reasons makes these posterior teeth readily available. The innovation of the method presented here is the optimal use of the extracted tooth substrate thanks to its positioning technique in the CAD/CAM milling chamber. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  9. Wear Behavior of Ceramic CAD/CAM Crowns and Natural Antagonists

    PubMed Central

    Naumova, Ella A.; Schneider, Stephan; Arnold, Wolfgang H.; Piwowarczyk, Andree

    2017-01-01

    Objective: Evaluation of wear behavior of computer-aided design/computer-aided manufacturing (CAD/CAM) crowns from various restorative materials and natural antagonists. Method: Full CAD/CAM crowns fabricated with nanoceramic resin (Lava Ultimate (LU)), a glass ceramic in a resin interpenetrating matrix (Vita Enamic (VE)) and a lithium silicate reinforced ceramic enriched with zirconia (Vita Suprinity (VS)) were cemented on human molars. The crown and antagonists were subjected to simulated chewing. 3D data sets, before and after the chewing simulation, were generated and matched. Occlusal surface roughness, vertical and volume loss of the crowns and antagonists were analyzed. Results: Crown roughness was significantly different between the LU and VE groups after chewing simulation. Crown vertical loss differed in all groups. The highest crown volume loss was found in the LU group, and the lowest in the VE group. Comparisons between the LU and VE groups and the LU and VS groups were significantly different. The highest antagonist volume loss was reached in the VE group, the lowest was in the LU group. Conclusion: Roughness increased after chewing simulation. LU crowns are the most natural antagonist-friendly; these were the most susceptible to vertical and volume loss. Of the tested materials, the VE crowns are the most stable regarding occlusion. PMID:28772602

  10. Effect of Clinically Relevant CAD/CAM Zirconia Polishing on Gingival Fibroblast Proliferation and Focal Adhesions

    PubMed Central

    Fischer, Nicholas G.; Wong, Jeffrey; Cerutis, D. Roselyn

    2017-01-01

    Mucosal seal formation around dental abutments is critical to the successful integration of dental implants into the human oral cavity. No information exists for how clinically relevant polishing procedures for computer-aided design and computer-aided manufactured (CAD/CAM) zirconia abutments affects cellular responses important to mucosal seal formation. CAD/CAM zirconia was divided into four groups for clinically relevant polishing utilizing commercial polishing heads: control, coarse, coarse plus medium, and coarse plus medium plus fine. Surfaces were analyzed with scanning electron microscopy (SEM), atomic force microscopy (AFM), and optical profilometry (OP). Subsequently, human gingival fibroblasts (HGFs) were seeded onto the zirconia surfaces. Proliferation was measured via a quantitative SEM technique and focal adhesion kinase (FAK) phosphorylation status was measured by an enzyme-linked immunosorbent assay (ELISA). Results showed an increase in proliferation on all polished surfaces as compared to the control. Phosphorylation of FAK at tyrosine 397 (Y397) was up-modulated on the control surfaces. The associated cell adaptation is discussed. In all cases, FAK phosphorylation was greater at 24 h than 48 h. These results suggest that clinicians should be mindful of the effects of abutment polishing methodology, as this may have an impact on early mucosal seal formation. PMID:29186907

  11. Short-Term Outcomes of Screening Mammography Using Computer-Aided Detection

    PubMed Central

    Fenton, Joshua J.; Xing, Guibo; Elmore, Joann G.; Bang, Heejung; Chen, Steven L.; Lindfors, Karen K.; Baldwin, Laura-Mae

    2013-01-01

    Background Computer-aided detection (CAD) has rapidly diffused into screening mammography practice despite limited and conflicting data on its clinical effect. Objective To determine associations between CAD use during screening mammography and the incidence of ductal carcinoma in situ (DCIS) and invasive breast cancer, invasive cancer stage, and diagnostic testing. Design Retrospective cohort study. Setting Medicare program. Participants Women aged 67 to 89 years having screening mammography between 2001 and 2006 in U.S. SEER (Surveillance, Epidemiology and End Results) regions (409 459 mammograms from 163 099 women). Measurements Incident DCIS and invasive breast cancer within 1 year after mammography, invasive cancer stage, and diagnostic testing within 90 days after screening among women without breast cancer. Results From 2001 to 2006, CAD prevalence increased from 3.6% to 60.5%. Use of CAD was associated with greater DCIS incidence (adjusted odds ratio [OR], 1.17 [95% CI, 1.11 to 1.23]) but no difference in invasive breast cancer incidence (adjusted OR, 1.00 [CI, 0.97 to 1.03]). Among women with invasive cancer, CAD was associated with greater likelihood of stage I to II versus III to IV cancer (adjusted OR, 1.27 [CI, 1.14 to 1.41]). In women without breast cancer, CAD was associated with increased odds of diagnostic mammography (adjusted OR, 1.28 [CI, 1.27 to 1.29]), breast ultrasonography (adjusted OR, 1.07 [CI, 1.06 to 1.09]), and breast biopsy (adjusted OR, 1.10 [CI, 1.08 to 1.12]). Limitation Short follow-up for cancer stage, potential unmeasured confounding, and uncertain generalizability to younger women. Conclusion Use of CAD during screening mammography among Medicare enrollees is associated with increased DCIS incidence, the diagnosis of invasive breast cancer at earlier stages, and increased diagnostic testing among women without breast cancer. Primary Funding Source Center for Healthcare Policy and Research, University of California, Davis. PMID:23588746

  12. Machinability of CAD-CAM materials.

    PubMed

    Chavali, Ramakiran; Nejat, Amir H; Lawson, Nathaniel C

    2017-08-01

    Although new materials are available for computer-aided design and computer-aided manufacturing (CAD-CAM) fabrication, limited information is available regarding their machinability. The depth of penetration of a milling tool into a material during a timed milling cycle may indicate its machinability. The purpose of this in vitro study was to compare the tool penetration rate for 2 polymer-containing CAD-CAM materials (Lava Ultimate and Enamic) and 2 ceramic-based CAD-CAM materials (e.max CAD and Celtra Duo). The materials were sectioned into 4-mm-thick specimens (n=5/material) and polished with 320-grit SiC paper. Each specimen was loaded into a custom milling apparatus. The apparatus pushed the specimens against a milling tool (E4D Tapered 2016000) rotating at 40 000 RPM with a constant force of 0.98 N. After a 6-minute timed milling cycle, the length of each milling cut was measured with image analysis software under a digital light microscope. Representative specimens and milling tools were examined with scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy. The penetration rate of Lava Ultimate (3.21 ±0.46 mm/min) and Enamic (2.53 ±0.57 mm/min) was significantly greater than that of e.max CAD (1.12 ±0.32 mm/min) or Celtra Duo (0.80 ±0.21 mm/min) materials. SEM observations showed little tool damage, regardless of material type. Residual material was found on the tools used with polymer-containing materials, and wear of the embedding medium was seen on the tools used with the ceramic-based materials. Edge chipping was noted on cuts made in the ceramic-based materials. Lava Ultimate and Enamic have greater machinability and less edge chipping than e.max CAD and Celtra Duo. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  13. Computer aided detection system for lung cancer using computer tomography scans

    NASA Astrophysics Data System (ADS)

    Mahesh, Shanthi; Rakesh, Spoorthi; Patil, Vidya C.

    2018-04-01

    Lung Cancer is a disease can be defined as uncontrolled cell growth in tissues of the lung. If we detect the Lung Cancer in its early stage, then that could be the key of its cure. In this work the non-invasive methods are studied for assisting in nodule detection. It supplies a Computer Aided Diagnosis System (CAD) for early detection of lung cancer nodules from the Computer Tomography (CT) images. CAD system is the one which helps to improve the diagnostic performance of radiologists in their image interpretations. The main aim of this technique is to develop a CAD system for finding the lung cancer using the lung CT images and classify the nodule as Benign or Malignant. For classifying cancer cells, SVM classifier is used. Here, image processing techniques have been used to de-noise, to enhance, for segmentation and edge detection of an image is used to extract the area, perimeter and shape of nodule. The core factors of this research are Image quality and accuracy.

  14. The efficacy of using computer-aided detection (CAD) for detection of breast cancer in mammography screening: a systematic review.

    PubMed

    Henriksen, Emilie L; Carlsen, Jonathan F; Vejborg, Ilse Mm; Nielsen, Michael B; Lauridsen, Carsten A

    2018-01-01

    Background Early detection of breast cancer (BC) is crucial in lowering the mortality. Purpose To present an overview of studies concerning computer-aided detection (CAD) in screening mammography for early detection of BC and compare diagnostic accuracy and recall rates (RR) of single reading (SR) with SR + CAD and double reading (DR) with SR + CAD. Material and Methods PRISMA guidelines were used as a review protocol. Articles on clinical trials concerning CAD for detection of BC in a screening population were included. The literature search resulted in 1522 records. A total of 1491 records were excluded by abstract and 18 were excluded by full text reading. A total of 13 articles were included. Results All but two studies from the SR vs. SR + CAD group showed an increased sensitivity and/or cancer detection rate (CDR) when adding CAD. The DR vs. SR + CAD group showed no significant differences in sensitivity and CDR. Adding CAD to SR increased the RR and decreased the specificity in all but one study. For the DR vs. SR + CAD group only one study reported a significant difference in RR. Conclusion All but two studies showed an increase in RR, sensitivity and CDR when adding CAD to SR. Compared to DR no statistically significant differences in sensitivity or CDR were reported. Additional studies based on organized population-based screening programs, with longer follow-up time, high-volume readers, and digital mammography are needed to evaluate the efficacy of CAD.

  15. Comparison of denture tooth movement between CAD-CAM and conventional fabrication techniques.

    PubMed

    Goodacre, Brian J; Goodacre, Charles J; Baba, Nadim Z; Kattadiyil, Mathew T

    2018-01-01

    Data comparing the denture tooth movement of computer-aided design and computer-aided manufacturing (CAD-CAM) and conventional denture processing techniques are lacking. The purpose of this in vitro study was to compare the denture tooth movement of pack-and-press, fluid resin, injection, CAD-CAM-bonded, and CAD-CAM monolithic techniques for fabricating dentures to determine which process produces the most accurate and reproducible prosthesis. A total of 50 dentures were evaluated, 10 for each of the 5 groups. A master denture was fabricated and milled from prepolymerized poly(methyl methacrylate). For the conventional processing techniques (pack-and-press, fluid resin, and injection) a polyvinyl siloxane putty mold of the master denture was made in which denture teeth were placed and molten wax injected. The cameo surface of each wax-festooned denture was laser scanned, resulting in a standard tessellation language (STL) format file. The CAD-CAM dentures included 2 subgroups: CAD-CAM-bonded teeth in which the denture teeth were bonded into the milled denture base and CAD-CAM monolithic teeth in which the denture teeth were milled as part of the denture base. After all specimens had been fabricated, they were hydrated for 24 hours, and the cameo surface laser scanned. The preprocessing and postprocessing scan files of each denture were superimposed using surface-matching software. Measurements were made at 64 locations, allowing evaluation of denture tooth movement in a buccal, lingual, mesial-distal, and occlusal direction. The use of median and interquartile range values was used to assess accuracy and reproducibility. Levene and Kruskal-Wallis analyses of variance were used to evaluate differences between processing techniques (α=.05). The CAD-CAM monolithic technique was the most accurate, followed by fluid resin, CAD-CAM-bonded, pack-and-press, and injection. CAD-CAM monolithic technique was the most reproducible, followed by pack-and-press, CAD-CAM-bonded, injection, and fluid resin. Techniques involving compression during processing showed increased positive occlusal tooth movement compared with techniques not involving compression. CAD-CAM monolithic dentures produced the best combination of accuracy and reproducibility of the tested techniques. The results from this study demonstrate that varying amounts of tooth movement can be expected depending on the processing technique. However, the clinical significance of these differences is unknown. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  16. Computer-aided-diagnosis (CAD) for colposcopy

    NASA Astrophysics Data System (ADS)

    Lange, Holger; Ferris, Daron G.

    2005-04-01

    Uterine cervical cancer is the second most common cancer among women worldwide. Colposcopy is a diagnostic method, whereby a physician (colposcopist) visually inspects the lower genital tract (cervix, vulva and vagina), with special emphasis on the subjective appearance of metaplastic epithelium comprising the transformation zone on the cervix. Cervical cancer precursor lesions and invasive cancer exhibit certain distinctly abnormal morphologic features. Lesion characteristics such as margin; color or opacity; blood vessel caliber, intercapillary spacing and distribution; and contour are considered by colposcopists to derive a clinical diagnosis. Clinicians and academia have suggested and shown proof of concept that automated image analysis of cervical imagery can be used for cervical cancer screening and diagnosis, having the potential to have a direct impact on improving women"s health care and reducing associated costs. STI Medical Systems is developing a Computer-Aided-Diagnosis (CAD) system for colposcopy -- ColpoCAD. At the heart of ColpoCAD is a complex multi-sensor, multi-data and multi-feature image analysis system. A functional description is presented of the envisioned ColpoCAD system, broken down into: Modality Data Management System, Image Enhancement, Feature Extraction, Reference Database, and Diagnosis and directed Biopsies. The system design and development process of the image analysis system is outlined. The system design provides a modular and open architecture built on feature based processing. The core feature set includes the visual features used by colposcopists. This feature set can be extended to include new features introduced by new instrument technologies, like fluorescence and impedance, and any other plausible feature that can be extracted from the cervical data. Preliminary results of our research on detecting the three most important features: blood vessel structures, acetowhite regions and lesion margins are shown. As this is a new and very complex field in medical image processing, the hope is that this paper can provide a framework and basis to encourage and facilitate collaboration and discussion between industry, academia, and medical practitioners.

  17. Prospective assessment of CAD/CAM zirconia abutment and lithium disilicate crown restorations: 2.4 year results.

    PubMed

    Cooper, Lyndon F; Stanford, Clark; Feine, Jocelyne; McGuire, Michael

    2016-07-01

    Single-tooth implant restorations are commonly used to replace anterior maxillary teeth. The esthetic, functional, and biologic outcomes are, in part, a function of the abutment and crown. The purpose of this clinical study was to describe the implant, abutment, and crown survival and complication rates for CAD/CAM zirconia abutment and lithium disilicate crown restorations for single-tooth implants. As part of a broader prospective investigation that enrolled and treated 141 participants comparing tissue responses at the conical interface (CI; AstraTech OsseoSpeed), flat-to-flat interface (FI; NobelSpeedy), and platform-switch interface (PS; NanoTite Certain Prevail) of single-tooth implants, computer-aided design and computer-aided manufacturing (CAD/CAM) zirconia abutments (ATLANTIS Abutment) and cemented lithium disilicate (e.max) crowns were used in the restoration of all implants. After 2.4 years in function (3 years after implant placement), the implant, abutment, and crown of 110 participants were evaluated. Technical and biologic complications were recorded. Demographic results were tabulated as percentages with mean values and standard deviations. Abutment survival was calculated with the Kaplan-Meier method. After 2.4 years, no abutments or crowns had been lost. Abutment complications (screw loosening, screw fracture, fracture) were absent for all 3 implant groups. Crown complications were limited to 2 crowns debonding and 1 with excess cement (2.5%). Five biological complications (4.0%) were recorded. The overall complication rate was 6.5%. CAD/CAM zirconia abutments restored with cemented lithium disilicate crowns demonstrated high survival on 3 different implant-abutment interface designs. No abutment or abutment screw fracture occurred. The technical complications observed after 2.4 years were minor and reversible. The use of CAD/CAM zirconia abutments with cemented lithium disilicate crowns is associated with high technical and biologic success at 2.4 years. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  18. Manufacturing cost/design system: A CAD/CAM dialogue

    NASA Technical Reports Server (NTRS)

    Loshigian, H. H.; Rachowitz, B. I.; Judson, D.

    1980-01-01

    The development of the Manufacturing Cost/Design System (MC/DS) will provide the aerospace design engineer a tool with which to perform heretofore impractical design manufacturing cost tradeoffs. The Air Force Integrated Computer Aided Manufacturing (ICAM) Office has initiated the development and demonstration of an MC/DS which, when fully implemented, will integrate both design and manufacturing data bases to provide real time visibility into the manufacturing costs associated with various design options. The first release of a computerized system will be made before the end of 1981.

  19. An open CAM system for dentistry on the basis of China-made 5-axis simultaneous contouring CNC machine tool and industrial CAM software.

    PubMed

    Lu, Li; Liu, Shusheng; Shi, Shenggen; Yang, Jianzhong

    2011-10-01

    China-made 5-axis simultaneous contouring CNC machine tool and domestically developed industrial computer-aided manufacture (CAM) technology were used for full crown fabrication and measurement of crown accuracy, with an attempt to establish an open CAM system for dental processing and to promote the introduction of domestic dental computer-aided design (CAD)/CAM system. Commercially available scanning equipment was used to make a basic digital tooth model after preparation of crown, and CAD software that comes with the scanning device was employed to design the crown by using domestic industrial CAM software to process the crown data in order to generate a solid model for machining purpose, and then China-made 5-axis simultaneous contouring CNC machine tool was used to complete machining of the whole crown and the internal accuracy of the crown internal was measured by using 3D-MicroCT. The results showed that China-made 5-axis simultaneous contouring CNC machine tool in combination with domestic industrial CAM technology can be used for crown making and the crown was well positioned in die. The internal accuracy was successfully measured by using 3D-MicroCT. It is concluded that an open CAM system for dentistry on the basis of China-made 5-axis simultaneous contouring CNC machine tool and domestic industrial CAM software has been established, and development of the system will promote the introduction of domestically-produced dental CAD/CAM system.

  20. Benefit of computer-aided detection analysis for the detection of subsolid and solid lung nodules on thin- and thick-section CT.

    PubMed

    Godoy, Myrna C B; Kim, Tae Jung; White, Charles S; Bogoni, Luca; de Groot, Patricia; Florin, Charles; Obuchowski, Nancy; Babb, James S; Salganicoff, Marcos; Naidich, David P; Anand, Vikram; Park, Sangmin; Vlahos, Ioannis; Ko, Jane P

    2013-01-01

    The objective of our study was to evaluate the impact of computer-aided detection (CAD) on the identification of subsolid and solid lung nodules on thin- and thick-section CT. For 46 chest CT examinations with ground-glass opacity (GGO) nodules, CAD marks computed using thin data were evaluated in two phases. First, four chest radiologists reviewed thin sections (reader(thin)) for nodules and subsequently CAD marks (reader(thin) + CAD(thin)). After 4 months, the same cases were reviewed on thick sections (reader(thick)) and subsequently with CAD marks (reader(thick) + CAD(thick)). Sensitivities were evaluated. Additionally, reader(thick) sensitivity with assessment of CAD marks on thin sections was estimated (reader(thick) + CAD(thin)). For 155 nodules (mean, 5.5 mm; range, 4.0-27.5 mm)-74 solid nodules, 22 part-solid (part-solid nodules), and 59 GGO nodules-CAD stand-alone sensitivity was 80%, 95%, and 71%, respectively, with three false-positives on average (0-12) per CT study. Reader(thin) + CAD(thin) sensitivities were higher than reader(thin) for solid nodules (82% vs 57%, p < 0.001), part-solid nodules (97% vs 81%, p = 0.0027), and GGO nodules (82% vs 69%, p < 0.001) for all readers (p < 0.001). Respective sensitivities for reader(thick), reader(thick) + CAD(thick), reader(thick) + CAD(thin) were 40%, 58% (p < 0.001), and 77% (p < 0.001) for solid nodules; 72%, 73% (p = 0.322), and 94% (p < 0.001) for part-solid nodules; and 53%, 58% (p = 0.008), and 79% (p < 0.001) for GGO nodules. For reader(thin), false-positives increased from 0.64 per case to 0.90 with CAD(thin) (p < 0.001) but not for reader(thick); false-positive rates were 1.17, 1.19, and 1.26 per case for reader(thick), reader(thick) + CAD(thick), and reader(thick) + CAD(thin), respectively. Detection of GGO nodules and solid nodules is significantly improved with CAD. When interpretation is performed on thick sections, the benefit is greater when CAD marks are reviewed on thin rather than thick sections.

  1. Computer-Aided Diagnosis Systems for Lung Cancer: Challenges and Methodologies

    PubMed Central

    El-Baz, Ayman; Beache, Garth M.; Gimel'farb, Georgy; Suzuki, Kenji; Okada, Kazunori; Elnakib, Ahmed; Soliman, Ahmed; Abdollahi, Behnoush

    2013-01-01

    This paper overviews one of the most important, interesting, and challenging problems in oncology, the problem of lung cancer diagnosis. Developing an effective computer-aided diagnosis (CAD) system for lung cancer is of great clinical importance and can increase the patient's chance of survival. For this reason, CAD systems for lung cancer have been investigated in a huge number of research studies. A typical CAD system for lung cancer diagnosis is composed of four main processing steps: segmentation of the lung fields, detection of nodules inside the lung fields, segmentation of the detected nodules, and diagnosis of the nodules as benign or malignant. This paper overviews the current state-of-the-art techniques that have been developed to implement each of these CAD processing steps. For each technique, various aspects of technical issues, implemented methodologies, training and testing databases, and validation methods, as well as achieved performances, are described. In addition, the paper addresses several challenges that researchers face in each implementation step and outlines the strengths and drawbacks of the existing approaches for lung cancer CAD systems. PMID:23431282

  2. A Comparison of the Flexural and Impact Strengths and Flexural Modulus of CAD/CAM and Conventional Heat-Cured Polymethyl Methacrylate (PMMA).

    PubMed

    Al-Dwairi, Ziad N; Tahboub, Kawkab Y; Baba, Nadim Z; Goodacre, Charles J

    2018-06-13

    The introduction of computer-aided design/computer-aided manufacturing (CAD/CAM) technology to the field of removable prosthodontics has recently made it possible to fabricate complete dentures of prepolymerized polymethyl methacrylate (PMMA) blocks, which are claimed to be of better mechanical properties; however, no published reports that have evaluated mechanical properties of CAD/CAM PMMA. The purpose of this study was to compare flexural strength, impact strength, and flexural modulus of two brands of CAD/CAM PMMA and a conventional heat-cured PMMA. 45 rectangular specimens (65 mm × 10 mm × 3 mm) were fabricated (15 CAD/CAM AvaDent PMMA specimens from AvaDent, 15 CAD/CAM Tizian PMMA specimens from Shütz Dental, 15 conventional Meliodent PMMA specimens from Heraeus Kulzer) and stored in distilled water at (37  ± 1°C) for 7 days. Specimens (N = 15) in each group were subjected to the three-point bending test and impact strength test, employing the Charpy configuration on unnotched specimens. The morphology of the fractured specimens was studied under a scanning electron microscope (SEM). Statistical analysis was performed using one-way ANOVA and Tukey pairwise multiple comparisons with 95% confidence interval. The Schütz Dental specimens showed the highest mean flexural strength (130.67 MPa) and impact strength (29.56 kg/m 2 ). The highest mean flexural modulus was recorded in the AvaDent group (2519.6 MPa). The conventional heat-cured group showed the lowest mean flexural strength (93.33 MPa), impact strength (14.756 kg/m 2 ), and flexural modulus (2117.2 MPa). Differences in means of flexural properties between AvaDent and Schütz Dental specimens were not statistically significant (p > 0.05). As CAD/CAM PMMA specimens exhibited improved flexural strength, flexural modulus, and impact strength in comparison to the conventional heat-cured groups, CAD/CAM dentures are expected to be more durable. Different brands of CAD/CAM PMMA may have inherent variations in mechanical properties. © 2018 by the American College of Prosthodontists.

  3. Marginal and internal adaptation of ceramic crown restorations fabricated with CAD/CAM technology and the heat-press technique.

    PubMed

    Mously, Hisham A; Finkelman, Matthew; Zandparsa, Roya; Hirayama, Hiroshi

    2014-08-01

    The accuracy of chairside computer-aided design and computer-aided manufacturing (CAD/CAM) restorations is questionable, and the effect of the die spacer settings is not well stated in the literature. The purpose of the study was to evaluate the marginal and internal adaptation of E4D crowns fabricated with different spacer thicknesses and to compare these crowns with those fabricated with the heat-press technique. The E4D system was used to fabricate 30 crowns for the first 3 groups, with different spacer thickness settings: 30 μm, 60 μm, and 100 μm. In the fourth group, 10 lithium disilicate crowns were fabricated with the heat-press technique. The occlusal gap, axial gap, vertical marginal gap, and absolute marginal discrepancy were evaluated by x-ray microtomography. Statistical significance was assessed with the Kruskal-Wallis test (α=.05). For post hoc analyses, the Mann-Whitney U test was used alongside the Bonferroni correction for multiple comparisons (α=.008). Within the CAD/CAM groups, the 30-μm spacer thickness resulted in the lowest median axial gap (90.04 μm), whereas the 60-μm spacer thickness resulted in the lowest median occlusal gap (152.39 μm). The median marginal gap values of the CAD/CAM-60 group (49.35 μm) and CAD/CAM-100 group (46.65 μm) were lower than those of the CAD/CAM-30 group (55.18 μm). No significant differences among the CAD/CAM groups were observed for absolute marginal discrepancy. The heat-press group had significantly different values than those of the CAD/CAM groups. The spacer thickness and fabrication technique affected the adaptation of ceramic crowns. The heat-press group yielded the best marginal and internal crown adaptation results. The 30- or 60-μm spacer settings are recommended for the E4D CAD/CAM system. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  4. A novel approach to malignant-benign classification of pulmonary nodules by using ensemble learning classifiers.

    PubMed

    Tartar, A; Akan, A; Kilic, N

    2014-01-01

    Computer-aided detection systems can help radiologists to detect pulmonary nodules at an early stage. In this paper, a novel Computer-Aided Diagnosis system (CAD) is proposed for the classification of pulmonary nodules as malignant and benign. The proposed CAD system using ensemble learning classifiers, provides an important support to radiologists at the diagnosis process of the disease, achieves high classification performance. The proposed approach with bagging classifier results in 94.7 %, 90.0 % and 77.8 % classification sensitivities for benign, malignant and undetermined classes (89.5 % accuracy), respectively.

  5. Spacesuit glove manufacturing enhancements through the use of advanced technologies

    NASA Astrophysics Data System (ADS)

    Cadogan, David; Bradley, David; Kosmo, Joseph

    The sucess of astronauts performing extravehicular activity (EVA) on orbit is highly dependent upon the performance of their spacesuit gloves.A study has recently been conducted to advance the development and manufacture of spacesuit gloves. The process replaces the manual techniques of spacesuit glove manufacture by utilizing emerging technologies such as laser scanning, Computer Aided Design (CAD), computer generated two-dimensional patterns from three-dimensionl surfaces, rapid prototyping technology, and laser cutting of materials, to manufacture the new gloves. Results of the program indicate that the baseline process will not increase the cost of the gloves as compared to the existing styles, and in production, may reduce the cost of the gloves. perhaps the most important outcome of the Laserscan process is that greater accuracy and design control can be realized. Greater accuracy was achieved in the baseline anthropometric measurement and CAD data measurement which subsequently improved the design feature. This effectively enhances glove performance through better fit and comfort.

  6. Learning-based image preprocessing for robust computer-aided detection

    NASA Astrophysics Data System (ADS)

    Raghupathi, Laks; Devarakota, Pandu R.; Wolf, Matthias

    2013-03-01

    Recent studies have shown that low dose computed tomography (LDCT) can be an effective screening tool to reduce lung cancer mortality. Computer-aided detection (CAD) would be a beneficial second reader for radiologists in such cases. Studies demonstrate that while iterative reconstructions (IR) improve LDCT diagnostic quality, it however degrades CAD performance significantly (increased false positives) when applied directly. For improving CAD performance, solutions such as retraining with newer data or applying a standard preprocessing technique may not be suffice due to high prevalence of CT scanners and non-uniform acquisition protocols. Here, we present a learning-based framework that can adaptively transform a wide variety of input data to boost an existing CAD performance. This not only enhances their robustness but also their applicability in clinical workflows. Our solution consists of applying a suitable pre-processing filter automatically on the given image based on its characteristics. This requires the preparation of ground truth (GT) of choosing an appropriate filter resulting in improved CAD performance. Accordingly, we propose an efficient consolidation process with a novel metric. Using key anatomical landmarks, we then derive consistent feature descriptors for the classification scheme that then uses a priority mechanism to automatically choose an optimal preprocessing filter. We demonstrate CAD prototype∗ performance improvement using hospital-scale datasets acquired from North America, Europe and Asia. Though we demonstrated our results for a lung nodule CAD, this scheme is straightforward to extend to other post-processing tools dedicated to other organs and modalities.

  7. Computer aided design of digital controller for radial active magnetic bearings

    NASA Technical Reports Server (NTRS)

    Cai, Zhong; Shen, Zupei; Zhang, Zuming; Zhao, Hongbin

    1992-01-01

    A five degree of freedom Active Magnetic Bearing (AMB) system is developed which is controlled by digital controllers. The model of the radial AMB system is linearized and the state equation is derived. Based on the state variables feedback theory, digital controllers are designed. The performance of the controllers are evaluated according to experimental results. The Computer Aided Design (CAD) method is used to design controllers for magnetic bearings. The controllers are implemented with a digital signal processing (DSP) system. The control algorithms are realized with real-time programs. It is very easy to change the controller by changing or modifying the programs. In order to identify the dynamic parameters of the controlled magnetic system, a special experiment was carried out. Also, the online Recursive Least Squares (RLS) parameter identification method is studied. It can be realized with the digital controllers. Online parameter identification is essential for the realization of an adaptive controller.

  8. High-frequency CAD-based scattering model: SERMAT

    NASA Astrophysics Data System (ADS)

    Goupil, D.; Boutillier, M.

    1991-09-01

    Specifications for an industrial radar cross section (RCS) calculation code are given: it must be able to exchange data with many computer aided design (CAD) systems, it must be fast, and it must have powerful graphic tools. Classical physical optics (PO) and equivalent currents (EC) techniques have proven their efficiency on simple objects for a long time. Difficult geometric problems occur when objects with very complex shapes have to be computed. Only a specific geometric code can solve these problems. We have established that, once these problems have been solved: (1) PO and EC give good results on complex objects of large size compared to wavelength; and (2) the implementation of these objects in a software package (SERMAT) allows fast and sufficiently precise domain RCS calculations to meet industry requirements in the domain of stealth.

  9. TinkerCell: modular CAD tool for synthetic biology.

    PubMed

    Chandran, Deepak; Bergmann, Frank T; Sauro, Herbert M

    2009-10-29

    Synthetic biology brings together concepts and techniques from engineering and biology. In this field, computer-aided design (CAD) is necessary in order to bridge the gap between computational modeling and biological data. Using a CAD application, it would be possible to construct models using available biological "parts" and directly generate the DNA sequence that represents the model, thus increasing the efficiency of design and construction of synthetic networks. An application named TinkerCell has been developed in order to serve as a CAD tool for synthetic biology. TinkerCell is a visual modeling tool that supports a hierarchy of biological parts. Each part in this hierarchy consists of a set of attributes that define the part, such as sequence or rate constants. Models that are constructed using these parts can be analyzed using various third-party C and Python programs that are hosted by TinkerCell via an extensive C and Python application programming interface (API). TinkerCell supports the notion of a module, which are networks with interfaces. Such modules can be connected to each other, forming larger modular networks. TinkerCell is a free and open-source project under the Berkeley Software Distribution license. Downloads, documentation, and tutorials are available at http://www.tinkercell.com. An ideal CAD application for engineering biological systems would provide features such as: building and simulating networks, analyzing robustness of networks, and searching databases for components that meet the design criteria. At the current state of synthetic biology, there are no established methods for measuring robustness or identifying components that fit a design. The same is true for databases of biological parts. TinkerCell's flexible modeling framework allows it to cope with changes in the field. Such changes may involve the way parts are characterized or the way synthetic networks are modeled and analyzed computationally. TinkerCell can readily accept third-party algorithms, allowing it to serve as a platform for testing different methods relevant to synthetic biology.

  10. TinkerCell: modular CAD tool for synthetic biology

    PubMed Central

    Chandran, Deepak; Bergmann, Frank T; Sauro, Herbert M

    2009-01-01

    Background Synthetic biology brings together concepts and techniques from engineering and biology. In this field, computer-aided design (CAD) is necessary in order to bridge the gap between computational modeling and biological data. Using a CAD application, it would be possible to construct models using available biological "parts" and directly generate the DNA sequence that represents the model, thus increasing the efficiency of design and construction of synthetic networks. Results An application named TinkerCell has been developed in order to serve as a CAD tool for synthetic biology. TinkerCell is a visual modeling tool that supports a hierarchy of biological parts. Each part in this hierarchy consists of a set of attributes that define the part, such as sequence or rate constants. Models that are constructed using these parts can be analyzed using various third-party C and Python programs that are hosted by TinkerCell via an extensive C and Python application programming interface (API). TinkerCell supports the notion of a module, which are networks with interfaces. Such modules can be connected to each other, forming larger modular networks. TinkerCell is a free and open-source project under the Berkeley Software Distribution license. Downloads, documentation, and tutorials are available at . Conclusion An ideal CAD application for engineering biological systems would provide features such as: building and simulating networks, analyzing robustness of networks, and searching databases for components that meet the design criteria. At the current state of synthetic biology, there are no established methods for measuring robustness or identifying components that fit a design. The same is true for databases of biological parts. TinkerCell's flexible modeling framework allows it to cope with changes in the field. Such changes may involve the way parts are characterized or the way synthetic networks are modeled and analyzed computationally. TinkerCell can readily accept third-party algorithms, allowing it to serve as a platform for testing different methods relevant to synthetic biology. PMID:19874625

  11. Gaps Analysis of Integrating Product Design, Manufacturing, and Quality Data in The Supply Chain Using Model-Based Definition

    PubMed Central

    Trainer, Asa; Hedberg, Thomas; Feeney, Allison Barnard; Fischer, Kevin; Rosche, Phil

    2017-01-01

    Advances in information technology triggered a digital revolution that holds promise of reduced costs, improved productivity, and higher quality. To ride this wave of innovation, manufacturing enterprises are changing how product definitions are communicated – from paper to models. To achieve industry's vision of the Model-Based Enterprise (MBE), the MBE strategy must include model-based data interoperability from design to manufacturing and quality in the supply chain. The Model-Based Definition (MBD) is created by the original equipment manufacturer (OEM) using Computer-Aided Design (CAD) tools. This information is then shared with the supplier so that they can manufacture and inspect the physical parts. Today, suppliers predominantly use Computer-Aided Manufacturing (CAM) and Coordinate Measuring Machine (CMM) models for these tasks. Traditionally, the OEM has provided design data to the supplier in the form of two-dimensional (2D) drawings, but may also include a three-dimensional (3D)-shape-geometry model, often in a standards-based format such as ISO 10303-203:2011 (STEP AP203). The supplier then creates the respective CAM and CMM models and machine programs to produce and inspect the parts. In the MBE vision for model-based data exchange, the CAD model must include product-and-manufacturing information (PMI) in addition to the shape geometry. Today's CAD tools can generate models with embedded PMI. And, with the emergence of STEP AP242, a standards-based model with embedded PMI can now be shared downstream. The on-going research detailed in this paper seeks to investigate three concepts. First, that the ability to utilize a STEP AP242 model with embedded PMI for CAD-to-CAM and CAD-to-CMM data exchange is possible and valuable to the overall goal of a more efficient process. Second, the research identifies gaps in tools, standards, and processes that inhibit industry's ability to cost-effectively achieve model-based-data interoperability in the pursuit of the MBE vision. Finally, it also seeks to explore the interaction between CAD and CMM processes and determine if the concept of feedback from CAM and CMM back to CAD is feasible. The main goal of our study is to test the hypothesis that model-based-data interoperability from CAD-to-CAM and CAD-to-CMM is feasible through standards-based integration. This paper presents several barriers to model-based-data interoperability. Overall, the project team demonstrated the exchange of product definition data between CAD, CAM, and CMM systems using standards-based methods. While gaps in standards coverage were identified, the gaps should not stop industry's progress toward MBE. The results of our study provide evidence in support of an open-standards method to model-based-data interoperability, which would provide maximum value and impact to industry. PMID:28691120

  12. [Computer aided design and manufacture of the porcelain fused to metal crown].

    PubMed

    Nie, Xin; Cheng, Xiaosheng; Dai, Ning; Yu, Qing; Hao, Guodong; Sun, Quanping

    2009-04-01

    In order to satisfy the current demand for fast and high-quality prosthodontics, we have carried out a research in the fabrication process of the porcelain fused to metal crown on molar with CAD/CAM technology. Firstly, we get the data of the surface mesh on preparation teeth through a 3D-optical grating measuring system. Then, we reconstruct the 3D-model crown with the computer-aided design software which was developed by ourselves. Finally, with the 3D-model data, we produce a metallic crown on a high-speed CNC carving machine. The result has proved that the metallic crown can match the preparation teeth ideally. The fabrication process is reliable and efficient, and the restoration is precise and steady in quality.

  13. Application of Particle Swarm Optimization in Computer Aided Setup Planning

    NASA Astrophysics Data System (ADS)

    Kafashi, Sajad; Shakeri, Mohsen; Abedini, Vahid

    2011-01-01

    New researches are trying to integrate computer aided design (CAD) and computer aided manufacturing (CAM) environments. The role of process planning is to convert the design specification into manufacturing instructions. Setup planning has a basic role in computer aided process planning (CAPP) and significantly affects the overall cost and quality of machined part. This research focuses on the development for automatic generation of setups and finding the best setup plan in feasible condition. In order to computerize the setup planning process, three major steps are performed in the proposed system: a) Extraction of machining data of the part. b) Analyzing and generation of all possible setups c) Optimization to reach the best setup plan based on cost functions. Considering workshop resources such as machine tool, cutter and fixture, all feasible setups could be generated. Then the problem is adopted with technological constraints such as TAD (tool approach direction), tolerance relationship and feature precedence relationship to have a completely real and practical approach. The optimal setup plan is the result of applying the PSO (particle swarm optimization) algorithm into the system using cost functions. A real sample part is illustrated to demonstrate the performance and productivity of the system.

  14. Functional evaluation of a CAD/CAM prosthesis for immediate defect repair after total maxillectomy: a case series of 18 patients with maxillary sinus cancer.

    PubMed

    Jiang, Fei-Fei; Hou, Yan; Lu, Li; Ding, Xiao-Xu; Li, Wei; Yan, Ai-Hui

    2015-01-01

    To evaluate the facial profiles and functional recovery of 18 patients treated by a computer-aided designed/manufactured hollow obturator prosthesis (CAD/CAM prosthesis) after total maxillectomy for malignant maxillary sinus tumor. A retrospective observational study was performed to evaluate the facial profiles and functional recovery of 18 patients with T3-4a N0 M0 maxillary sinus cancer, who were treated by total maxillectomy and simultaneous implantation of a computer-aided designed/manufactured hollow obturator prosthesis (CAD/CAM prosthesis). Follow-ups were performed 1, 3, 6, and 12 months after surgery. Facial measurements, speech intelligibility, and chewing and swallowing functions were examined. Thirteen patients converted to a permanent prosthesis 6 months after surgery. Comparisons were made between patients with and without the CAD/CAM or permanent prosthesis at various times using SPSS13.0 statistical software (SPSS Inc., Chicago, IL, USA). Speech intelligibility, facial depression, and eyeball prolapse results showed improvements with prosthesis use at 1, 3, and 6 months after surgery (p < 0.05). Swallowing function improved from level V to level II-IV with prosthesis use at 1, 3, and 6 months, and reached level I or II with permanent prosthesis use at 12 months after surgery. Simultaneous CAD/CAM prosthesis implantation recovered the facial profile, enhanced the speaking, swallowing, and chewing functions, and improved the quality of life of patients. Tumor recurrence can be detected by direct observation of the postoperative maxillary cavity. Therefore, this operation is recommended for simultaneous excision repair and functional reconstruction after total maxillectomy. This surgical treatment of maxillary sinus cancer is applied rarely in China, but it has a good effect based on our observation. Simultaneous CAD/CAM prosthesis implantation after total maxillectomy can recover the facial profile, enhance the speaking, swallowing, and chewing functions, and improve the quality of life of patients. Tumor recurrence can be detected by direct observation of the postoperative maxillary cavity. This technique avoids the need for dental implants because the bottom part of the prosthesis contains a palatal plate with dentures. © 2014 Wiley Periodicals, Inc.

  15. The National Shipbuilding Research Program. 1989 Ship Production Symposium. Paper No. 13: NIDDESC: Meeting the Data Exchange Challenge Through a Cooperative Effort

    DTIC Science & Technology

    1989-09-01

    RESPONSIBLE PERSON a. REPORT unclassified b. ABSTRACT unclassified c . THIS PAGE unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18... Computer Aided Design (CAD) and Manufacturing (CAM) techniques in the marine industry has increased significantly in recent years, With more...somewhat from ship to ship. All of the activities and companies involved have improved this process by utilizing computer tools. For example, many

  16. Sockets Manufactured by CAD/CAM Method Have Positive Effects on the Quality of Life of Patients With Transtibial Amputation.

    PubMed

    Karakoç, Mehmet; Batmaz, İbrahim; Sariyildiz, Mustafa Akif; Yazmalar, Levent; Aydin, Abdülkadir; Em, Serda

    2017-08-01

    Patients with amputation need prosthesis to comfortably move around. One of the most important parts of a good prosthesis is the socket. Currently, the most commonly used method is the traditional socket manufacturing method, which involves manual work; however, computer-aided design/computer-aided manufacturing (CAD/CAM) is also being used in the recent years. The present study aimed to investigate the effects of sockets manufactured by traditional and CAD/CAM method on clinical characteristics and quality of life of patients with transtibial amputation. The study included 72 patients with transtibial amputation using prosthesis, 36 of whom had CAD/CAM prosthetic sockets (group 1) and 36 had traditional prosthetic sockets (group 2). Amputation reason, prosthesis lifetime, walking time and distance with prosthesis, pain-free walking time with prosthesis, production time of the prosthesis, and adaptation time to the prosthesis were questioned. Quality of life was assessed using the 36-item Short Form Health Survey questionnaire and the Trinity Amputation and Prosthesis Experience Scales. Walking time and distance and pain-free walking time with prosthesis were significantly better in group 1 than those in group 2. Furthermore, the prosthesis was applied in a significantly shorter time, and socket adaptation time was significantly shorter in group 1. Except emotional role limitation, all 36-item Short Form Healthy Survey questionnaire parameters were significantly better in group 1 than in group 2. Trinity Amputation and Prosthesis Experience Scales activity limitation scores of group 1 were lower, and Trinity Amputation and Prosthesis Experience Scales satisfaction with the prosthesis scores were higher than those in group 2. Our study demonstrated that the sockets manufactured by CAD/CAM methods yield better outcomes in quality of life of patients with transtibial amputation than the sockets manufactured by the traditional method.

  17. Imaging Performance of a Handheld Ultrasound System With Real-Time Computer-Aided Detection of Lumbar Spine Anatomy: A Feasibility Study.

    PubMed

    Tiouririne, Mohamed; Dixon, Adam J; Mauldin, F William; Scalzo, David; Krishnaraj, Arun

    2017-08-01

    The aim of this study was to evaluate the imaging performance of a handheld ultrasound system and the accuracy of an automated lumbar spine computer-aided detection (CAD) algorithm in the spines of human subjects. This study was approved by the institutional review board of the University of Virginia. The authors designed a handheld ultrasound system with enhanced bone image quality and fully automated CAD of lumbar spine anatomy. The imaging performance was evaluated by imaging the lumbar spines of 68 volunteers with body mass index between 18.5 and 48 kg/m. The accuracy, sensitivity, and specificity of the lumbar spine CAD algorithm were assessed by comparing the algorithm's results to ground-truth segmentations of neuraxial anatomy provided by radiologists. The lumbar spine CAD algorithm detected the epidural space with a sensitivity of 94.2% (95% confidence interval [CI], 85.1%-98.1%) and a specificity of 85.5% (95% CI, 81.7%-88.6%) and measured its depth with an error of approximately ±0.5 cm compared with measurements obtained manually from the 2-dimensional ultrasound images. The spine midline was detected with a sensitivity of 93.9% (95% CI, 85.8%-97.7%) and specificity of 91.3% (95% CI, 83.6%-96.9%), and its lateral position within the ultrasound image was measured with an error of approximately ±0.3 cm. The bone enhancement imaging mode produced images with 5.1- to 10-fold enhanced bone contrast when compared with a comparable handheld ultrasound imaging system. The results of this study demonstrate the feasibility of CAD for assisting with real-time interpretation of ultrasound images of the lumbar spine at the bedside.

  18. Digital versus conventional techniques for pattern fabrication of implant-supported frameworks

    PubMed Central

    Alikhasi, Marzieh; Rohanian, Ahmad; Ghodsi, Safoura; Kolde, Amin Mohammadpour

    2018-01-01

    Objective: The aim of this experimental study was to compare retention of frameworks cast from wax patterns fabricated by three different methods. Materials and Methods: Thirty-six implant analogs connected to one-piece abutments were divided randomly into three groups according to the wax pattern fabrication method (n = 12). Computer-aided design/computer-aided manufacturing (CAD/CAM) milling machine, three-dimensional printer, and conventional technique were used for fabrication of waxing patterns. All laboratory procedures were performed by an expert-reliable technician to eliminate intra-operator bias. The wax patterns were cast, finished, and seated on related abutment analogs. The number of adjustment times was recorded and analyzed by Kruskal–Wallis test. Frameworks were cemented on the corresponding analogs with zinc phosphate cement and tensile resistance test was used to measure retention value. Statistical Analysis Used: One-way analysis of variance (ANOVA) and post hoc Tukey tests were used for statistical analysis. Level of significance was set at P < 0.05. Results: The mean retentive values of 680.36 ± 21.93 N, 440.48 ± 85.98 N, and 407.23 ± 67.48 N were recorded for CAD/CAM, rapid prototyping, and conventional group, respectively. One-way ANOVA test revealed significant differences among the three groups (P < 0.001). The post hoc Tukey test showed significantly higher retention for CAD/CAM group (P < 0.001), while there was no significant difference between the two other groups (P = 0.54). CAD/CAM group required significantly more adjustments (P < 0.001). Conclusions: CAD/CAM-fabricated wax patterns showed significantly higher retention for implant-supported cement-retained frameworks; this could be a valuable help when there are limitations in the retention of single-unit implant restorations. PMID:29657528

  19. Digital versus conventional techniques for pattern fabrication of implant-supported frameworks.

    PubMed

    Alikhasi, Marzieh; Rohanian, Ahmad; Ghodsi, Safoura; Kolde, Amin Mohammadpour

    2018-01-01

    The aim of this experimental study was to compare retention of frameworks cast from wax patterns fabricated by three different methods. Thirty-six implant analogs connected to one-piece abutments were divided randomly into three groups according to the wax pattern fabrication method ( n = 12). Computer-aided design/computer-aided manufacturing (CAD/CAM) milling machine, three-dimensional printer, and conventional technique were used for fabrication of waxing patterns. All laboratory procedures were performed by an expert-reliable technician to eliminate intra-operator bias. The wax patterns were cast, finished, and seated on related abutment analogs. The number of adjustment times was recorded and analyzed by Kruskal-Wallis test. Frameworks were cemented on the corresponding analogs with zinc phosphate cement and tensile resistance test was used to measure retention value. One-way analysis of variance (ANOVA) and post hoc Tukey tests were used for statistical analysis. Level of significance was set at P < 0.05. The mean retentive values of 680.36 ± 21.93 N, 440.48 ± 85.98 N, and 407.23 ± 67.48 N were recorded for CAD/CAM, rapid prototyping, and conventional group, respectively. One-way ANOVA test revealed significant differences among the three groups ( P < 0.001). The post hoc Tukey test showed significantly higher retention for CAD/CAM group ( P < 0.001), while there was no significant difference between the two other groups ( P = 0.54). CAD/CAM group required significantly more adjustments ( P < 0.001). CAD/CAM-fabricated wax patterns showed significantly higher retention for implant-supported cement-retained frameworks; this could be a valuable help when there are limitations in the retention of single-unit implant restorations.

  20. Comparative evaluation of bonding strength of computer aided machined ceramic, pressable ceramic, and milled metal implant abutment copings and effect of surface conditioning on bonding strength: An in vitro study

    PubMed Central

    Rani, Sapna; Verma, Mahesh; Gill, Shubhra; Gupta, Rekha

    2016-01-01

    Background/Purpose: The aim of this study was to compare the shear bond strength of computer aided design/computer aided machined ceramic (CAD/CAM), pressable ceramic, and milled metal implant copings on abutment and the effect of surface conditioning on bonding strength. Materials and Methods: A total of 90 test samples were fabricated on three titanium abutments. Among 90 test samples, 30 copings were fabricated by CAD/CAM, 30 by pressable, and 30 by milling of titanium metal. These 30 test samples in each group were further subdivided equally for surface treatment. Fifteen out of 30 test samples in each group were surface conditioned with airborne particle abrasion. All the 90 test samples were luted on abutment with glass ionomer cement. Bonding strength was evaluated for all the samples using universal testing machine at a crosshead speed of 5 mm/min. The results obtained were compared and evaluated using one-way ANOVA with post-hoc and unpaired t-test at a significance level of 0.05. Results: The mean difference for CAD/CAM surface conditioned subgroup was 1.28 ± 0.12, for nonconditioned subgroup was 1.20 ± 0.11. The mean difference for pressable surface conditioned subgroup was 1.18 ± 0.04, and for nonconditioned subgroup was 0.75 ± 0.28. The mean difference for milled metal surface conditioned subgroup was 2.57 ± 0.58, and for nonconditioned subgroup was 1.49 ± 0.15. Conclusions: On comparison of bonding strength, milled metal copings had an edge over the other two materials, and surface conditioning increased the bond strength. PMID:27141163

Top