WE-E-217A-02: Methodologies for Evaluation of Standalone CAD System Performance.
Sahiner, B
2012-06-01
Standalone performance evaluation of a CAD system provides information about the abnormality detection or classification performance of the computerized system alone. Although the performance of the reader with CAD is the final step in CAD system assessment, standalone performance evaluation is an important component for several reasons: First, standalone evaluation informs the reader about the performance level of the CAD system and may have an impact on how the reader uses the system. Second, it provides essential information to the system designer for algorithm optimization during system development. Third, standalone evaluation can provide a detailed description of algorithm performance (e.g., on subgroups of the population) because a larger data set with more samples from different subgroups can be included in standalone studies compared to reader studies. Proper standalone evaluation of a CAD system involves a number of key components, some of which are shared with the assessment of reader performance with CAD. These include (1) selection of a test data set that allows performance assessment with little or no bias and acceptable uncertainty; (2) a reference standard that indicates disease status as well as the location and extent of disease; (3) a clearly defined method for labeling each CAD mark as a true-positive or false-positive; and (4) a properly selected set of metrics to summarize the accuracy of the computer marks and their corresponding scores. In this lecture, we will discuss various approaches for the key components of standalone CAD performance evaluation listed above, and present some of the recommendations and opinions from the AAPM CAD subcommittee on these issues. Learning Objectives 1. Identify basic components and metrics in the assessment of standalone CAD systems 2. Understand how each component may affect the assessed performance 3. Learn about AAPM CAD subcommittee's opinions and recommendations on factors and metrics related to the evaluation of standalone CAD system performance. © 2012 American Association of Physicists in Medicine.
Performance evaluation of the NASA/KSC CAD/CAE and office automation LAN's
NASA Technical Reports Server (NTRS)
Zobrist, George W.
1994-01-01
This study's objective is the performance evaluation of the existing CAD/CAE (Computer Aided Design/Computer Aided Engineering) network at NASA/KSC. This evaluation also includes a similar study of the Office Automation network, since it is being planned to integrate this network into the CAD/CAE network. The Microsoft mail facility which is presently on the CAD/CAE network was monitored to determine its present usage. This performance evaluation of the various networks will aid the NASA/KSC network managers in planning for the integration of future workload requirements into the CAD/CAE network and determining the effectiveness of the planned FDDI (Fiber Distributed Data Interface) migration.
Reduction of bias and variance for evaluation of computer-aided diagnostic schemes.
Li, Qiang; Doi, Kunio
2006-04-01
Computer-aided diagnostic (CAD) schemes have been developed to assist radiologists in detecting various lesions in medical images. In addition to the development, an equally important problem is the reliable evaluation of the performance levels of various CAD schemes. It is good to see that more and more investigators are employing more reliable evaluation methods such as leave-one-out and cross validation, instead of less reliable methods such as resubstitution, for assessing their CAD schemes. However, the common applications of leave-one-out and cross-validation evaluation methods do not necessarily imply that the estimated performance levels are accurate and precise. Pitfalls often occur in the use of leave-one-out and cross-validation evaluation methods, and they lead to unreliable estimation of performance levels. In this study, we first identified a number of typical pitfalls for the evaluation of CAD schemes, and conducted a Monte Carlo simulation experiment for each of the pitfalls to demonstrate quantitatively the extent of bias and/or variance caused by the pitfall. Our experimental results indicate that considerable bias and variance may exist in the estimated performance levels of CAD schemes if one employs various flawed leave-one-out and cross-validation evaluation methods. In addition, for promoting and utilizing a high standard for reliable evaluation of CAD schemes, we attempt to make recommendations, whenever possible, for overcoming these pitfalls. We believe that, with the recommended evaluation methods, we can considerably reduce the bias and variance in the estimated performance levels of CAD schemes.
Evaluation of computer-aided detection and diagnosis systems.
Petrick, Nicholas; Sahiner, Berkman; Armato, Samuel G; Bert, Alberto; Correale, Loredana; Delsanto, Silvia; Freedman, Matthew T; Fryd, David; Gur, David; Hadjiiski, Lubomir; Huo, Zhimin; Jiang, Yulei; Morra, Lia; Paquerault, Sophie; Raykar, Vikas; Samuelson, Frank; Summers, Ronald M; Tourassi, Georgia; Yoshida, Hiroyuki; Zheng, Bin; Zhou, Chuan; Chan, Heang-Ping
2013-08-01
Computer-aided detection and diagnosis (CAD) systems are increasingly being used as an aid by clinicians for detection and interpretation of diseases. Computer-aided detection systems mark regions of an image that may reveal specific abnormalities and are used to alert clinicians to these regions during image interpretation. Computer-aided diagnosis systems provide an assessment of a disease using image-based information alone or in combination with other relevant diagnostic data and are used by clinicians as a decision support in developing their diagnoses. While CAD systems are commercially available, standardized approaches for evaluating and reporting their performance have not yet been fully formalized in the literature or in a standardization effort. This deficiency has led to difficulty in the comparison of CAD devices and in understanding how the reported performance might translate into clinical practice. To address these important issues, the American Association of Physicists in Medicine (AAPM) formed the Computer Aided Detection in Diagnostic Imaging Subcommittee (CADSC), in part, to develop recommendations on approaches for assessing CAD system performance. The purpose of this paper is to convey the opinions of the AAPM CADSC members and to stimulate the development of consensus approaches and "best practices" for evaluating CAD systems. Both the assessment of a standalone CAD system and the evaluation of the impact of CAD on end-users are discussed. It is hoped that awareness of these important evaluation elements and the CADSC recommendations will lead to further development of structured guidelines for CAD performance assessment. Proper assessment of CAD system performance is expected to increase the understanding of a CAD system's effectiveness and limitations, which is expected to stimulate further research and development efforts on CAD technologies, reduce problems due to improper use, and eventually improve the utility and efficacy of CAD in clinical practice.
Evaluation of computer-aided detection and diagnosis systemsa)
Petrick, Nicholas; Sahiner, Berkman; Armato, Samuel G.; Bert, Alberto; Correale, Loredana; Delsanto, Silvia; Freedman, Matthew T.; Fryd, David; Gur, David; Hadjiiski, Lubomir; Huo, Zhimin; Jiang, Yulei; Morra, Lia; Paquerault, Sophie; Raykar, Vikas; Samuelson, Frank; Summers, Ronald M.; Tourassi, Georgia; Yoshida, Hiroyuki; Zheng, Bin; Zhou, Chuan; Chan, Heang-Ping
2013-01-01
Computer-aided detection and diagnosis (CAD) systems are increasingly being used as an aid by clinicians for detection and interpretation of diseases. Computer-aided detection systems mark regions of an image that may reveal specific abnormalities and are used to alert clinicians to these regions during image interpretation. Computer-aided diagnosis systems provide an assessment of a disease using image-based information alone or in combination with other relevant diagnostic data and are used by clinicians as a decision support in developing their diagnoses. While CAD systems are commercially available, standardized approaches for evaluating and reporting their performance have not yet been fully formalized in the literature or in a standardization effort. This deficiency has led to difficulty in the comparison of CAD devices and in understanding how the reported performance might translate into clinical practice. To address these important issues, the American Association of Physicists in Medicine (AAPM) formed the Computer Aided Detection in Diagnostic Imaging Subcommittee (CADSC), in part, to develop recommendations on approaches for assessing CAD system performance. The purpose of this paper is to convey the opinions of the AAPM CADSC members and to stimulate the development of consensus approaches and “best practices” for evaluating CAD systems. Both the assessment of a standalone CAD system and the evaluation of the impact of CAD on end-users are discussed. It is hoped that awareness of these important evaluation elements and the CADSC recommendations will lead to further development of structured guidelines for CAD performance assessment. Proper assessment of CAD system performance is expected to increase the understanding of a CAD system's effectiveness and limitations, which is expected to stimulate further research and development efforts on CAD technologies, reduce problems due to improper use, and eventually improve the utility and efficacy of CAD in clinical practice. PMID:23927365
Goldkorn, Ronen; Goitein, Orly; Ben-Zekery, Sagit; Shlomo, Nir; Narodetsky, Michael; Livne, Moran; Sabbag, Avi; Asher, Elad; Matetzky, Shlomi
2016-01-01
An accelerated diagnostic protocol for evaluating low-risk patients with acute chest pain in a cardiologist-based chest pain unit (CPU) is widely employed today. However, limited data exist regarding the feasibility of such an algorithm for patients with a history of prior coronary artery disease (CAD). The aim of the current study was to assess the feasibility and safety of evaluating patients with a history of prior CAD using an accelerated diagnostic protocol. We evaluated 1,220 consecutive patients presenting with acute chest pain and hospitalized in our CPU. Patients were stratified according to whether they had a history of prior CAD or not. The primary composite outcome was defined as a composite of readmission due to chest pain, acute coronary syndrome, coronary revascularization, or death during a 60-day follow-up period. Overall, 268 (22%) patients had a history of prior CAD. Non-invasive evaluation was performed in 1,112 (91%) patients. While patients with a history of prior CAD had more comorbidities, the two study groups were similar regarding hospitalization rates (9% vs. 13%, p = 0.08), coronary angiography (13% vs. 11%, p = 0.41), and revascularization (6.5% vs. 5.7%, p = 0.8) performed during CPU evaluation. At 60-days the primary endpoint was observed in 12 (1.6%) and 6 (3.2%) patients without and with a history of prior CAD, respectively (p = 0.836). No mortalities were recorded. To conclude, Patients with a history of prior CAD can be expeditiously and safely evaluated using an accelerated diagnostic protocol in a CPU with outcomes not differing from patients without such a history. PMID:27669521
Studying the Relation of Postprandial Triglyceride with Coronary Artery Disease (CAD).
Manochehri, Mohammad; Moghadam, Adel Johari
2016-07-27
Coronary artery disease (CAD) is the most common cause of mortality worldwide and determination of contributing factors is essential. This study was conducted to study the relation of postprandial triglyceride as a risk of coronary artery disease in patients with proven CAD by angiography, referred to 502 Hospital of Army in 2015. This observational study conducted as a case-control and contained 80 male participants referred to 502 Hospital of Army. Half of these participants had proven CAD by angiography test and the other ones were healthy as a control group. Fasting serum triglyceride was evaluated in all participants and postprandial TG was checked 4 hours after a standard meal. Obtained data were analyzed by SPSS ver. 13. The results indicated that fasting TG and postprandial TG level were significantly higher in CAD patients (P-value=0.001). It was also shown evaluation of postprandial TG is more sensitive test than fasting TG in case of CAD patients. Our obtained results shown, evaluation of high level of postprandial TG is more reliable than fasting TG for patients whom suffer from CAD.
Evaluation of Five Microcomputer CAD Packages.
ERIC Educational Resources Information Center
Leach, James A.
1987-01-01
Discusses the similarities, differences, advanced features, applications and number of users of five microcomputer computer-aided design (CAD) packages. Included are: "AutoCAD (V.2.17)"; "CADKEY (V.2.0)"; "CADVANCE (V.1.0)"; "Super MicroCAD"; and "VersaCAD Advanced (V.4.00)." Describes the…
Kao, E-Fong; Liu, Gin-Chung; Lee, Lo-Yeh; Tsai, Huei-Yi; Jaw, Twei-Shiun
2015-06-01
The ability to give high priority to examinations with pathological findings could be very useful to radiologists with large work lists who wish to first evaluate the most critical studies. A computer-aided detection (CAD) system for identifying chest examinations with abnormalities has therefore been developed. To evaluate the effectiveness of a CAD system on report turnaround times of chest examinations with abnormalities. The CAD system was designed to automatically mark chest examinations with possible abnormalities in the work list of radiologists interpreting chest examinations. The system evaluation was performed in two phases: two radiologists interpreted the chest examinations without CAD in phase 1 and with CAD in phase 2. The time information recorded by the radiology information system was then used to calculate the turnaround times. All chest examinations were reviewed by two other radiologists and were divided into normal and abnormal groups. The turnaround times for the examinations with pathological findings with and without the CAD system assistance were compared. The sensitivity and specificity of the CAD for chest abnormalities were 0.790 and 0.697, respectively, and use of the CAD system decreased the turnaround time for chest examinations with abnormalities by 44%. The turnaround times required for radiologists to identify chest examinations with abnormalities could be reduced by using the CAD system. This system could be useful for radiologists with large work lists who wish to first evaluate the most critical studies. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Dachman, Abraham H.; Wroblewski, Kristen; Vannier, Michael W.; Horne, John M.
2014-01-01
Computed tomography (CT) colonography is a screening modality used to detect colonic polyps before they progress to colorectal cancer. Computer-aided detection (CAD) is designed to decrease errors of detection by finding and displaying polyp candidates for evaluation by the reader. CT colonography CAD false-positive results are common and have numerous causes. The relative frequency of CAD false-positive results and their effect on reader performance on the basis of a 19-reader, 100-case trial shows that the vast majority of CAD false-positive results were dismissed by readers. Many CAD false-positive results are easily disregarded, including those that result from coarse mucosa, reconstruction, peristalsis, motion, streak artifacts, diverticulum, rectal tubes, and lipomas. CAD false-positive results caused by haustral folds, extracolonic candidates, diminutive lesions (<6 mm), anal papillae, internal hemorrhoids, varices, extrinsic compression, and flexural pseudotumors are almost always recognized and disregarded. The ileocecal valve and tagged stool are common sources of CAD false-positive results associated with reader false-positive results. Nondismissable CAD soft-tissue polyp candidates larger than 6 mm are another common cause of reader false-positive results that may lead to further evaluation with follow-up CT colonography or optical colonoscopy. Strategies for correctly evaluating CAD polyp candidates are important to avoid pitfalls from common sources of CAD false-positive results. ©RSNA, 2014 PMID:25384290
Computer-aided detection (CAD) of breast cancer on full field digital and screening film mammograms
NASA Astrophysics Data System (ADS)
Sun, Xuejun; Qian, Wei; Song, Xiaoshan; Qian, Yuyan; Song, Dansheng; Clark, Robert A.
2003-05-01
Full-field digital mammography (FFDM) as a new breast imaging modality has potential to detect more breast cancers or to detect them at smaller sizes and earlier stages compared with screening film mammography (SFM). However, its performance needs verification, and it would pose new problems for the development of CAD methods for breast cancer detection and diagnosis. Performance evaluation of CAD systems on FFDM and SFM has been conducted in this study, respectively. First, an adaptive CAD system employing a series of advanced modules has been developed on FFDM. Second, a standardization approach has been developed to make the CAD system independent of characteristics of digitizer or imaging modalities for mammography. CAD systems developed previously for SFM and developed in this study for FFDM have been evaluated on FFDM and SFM images without and with standardization, respectively, to examine the performance improvement of the CAD system developed in this study. Computerized free-response receiver operating characteristic (FROC) analysis has been adopted as performance evaluation method. Compared with previous one, the CAD system developed in this study demonstrated significantly performance improvements. However, the comparison results have shown that the performances of final CAD system in this study are not significantly different on FFDM and on SFM after standardization. It needs further study on the assessment of CAD system performance on FFDM and SFM modalities.
Kobayashi, Hajime; Ohkubo, Masaki; Narita, Akihiro; Marasinghe, Janaka C; Murao, Kohei; Matsumoto, Toru; Sone, Shusuke
2017-01-01
Objective: We propose the application of virtual nodules to evaluate the performance of computer-aided detection (CAD) of lung nodules in cancer screening using low-dose CT. Methods: The virtual nodules were generated based on the spatial resolution measured for a CT system used in an institution providing cancer screening and were fused into clinical lung images obtained at that institution, allowing site specificity. First, we validated virtual nodules as an alternative to artificial nodules inserted into a phantom. In addition, we compared the results of CAD analysis between the real nodules (n = 6) and the corresponding virtual nodules. Subsequently, virtual nodules of various sizes and contrasts between nodule density and background density (ΔCT) were inserted into clinical images (n = 10) and submitted for CAD analysis. Results: In the validation study, 46 of 48 virtual nodules had the same CAD results as artificial nodules (kappa coefficient = 0.913). Real nodules and the corresponding virtual nodules showed the same CAD results. The detection limits of the tested CAD system were determined in terms of size and density of peripheral lung nodules; we demonstrated that a nodule with a 5-mm diameter was detected when the nodule had a ΔCT > 220 HU. Conclusion: Virtual nodules are effective in evaluating CAD performance using site-specific scan/reconstruction conditions. Advances in knowledge: Virtual nodules can be an effective means of evaluating site-specific CAD performance. The methodology for guiding the detection limit for nodule size/density might be a useful evaluation strategy. PMID:27897029
Effectiveness and efficiency of a CAD/CAM orthodontic bracket system.
Brown, Matthew W; Koroluk, Lorne; Ko, Ching-Chang; Zhang, Kai; Chen, Mengqi; Nguyen, Tung
2015-12-01
The first straight-wire appliance was introduced over 40 years ago to increase the consistency and efficiency of orthodontic treatment. More recently, computer-aided design and computer-aided manufacturing (CAD/CAM) technology has been used to create individualized orthodontic appliances. The purpose of this study was to investigate the clinical effectiveness and efficiency of CAD/CAM customized orthodontic appliances compared with direct and indirect bonded stock orthodontic brackets. This retrospective study included 3 treatment groups: group 1 patients were direct bonded with self-ligating appliances, group 2 patients were indirect bonded with self-ligating appliances, and group 3 patients were indirect bonded with CAD/CAM self-ligating appliances. Complete pretreatment and posttreatment records were obtained for all patients. The American Board of Orthodontics (ABO) Discrepancy Index was used to evaluate the pretreatment records, and the posttreatment outcomes were analyzed using the ABO Cast-Radiograph Evaluation. All data collection and analysis were completed by 1 evaluator. There were no statistically significant differences in the ABO Discrepancy Index or the ABO Cast-Radiograph Evaluation among the groups. Treatment times for the 3 groups were significantly different; the CAD/CAM group was the shortest at 13.8 ± 3.4 months, compared with 21.9 ± 5.0 and 16.9 ± 4.1 months for the direct bonded and indirect bonded groups, respectively. The number of treatment appointments for the CAD/CAM group was significantly fewer than for the direct bonded group. The CAD/CAM orthodontic bracket system evaluated in this study was as effective in treatment outcome measures as were standard brackets bonded both directly and indirectly. The CAD/CAM appliance was more efficient in regard to treatment duration, although the decrease in total archwire appointments was minimal. Further investigation is needed to better quantify the clinical benefits of CAD/CAM orthodontic appliances. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
Studying the Relation of Postprandial Triglyceride with Coronary Artery Disease (CAD)
Manochehri, Mohammad; Moghadam, Adel Johari
2016-01-01
Background: Coronary artery disease (CAD) is the most common cause of mortality worldwide and determination of contributing factors is essential. Aim: This study was conducted to study the relation of postprandial triglyceride as a risk of coronary artery disease in patients with proven CAD by angiography, referred to 502 Hospital of Army in 2015. Material and Methods: This observational study conducted as a case-control and contained 80 male participants referred to 502 Hospital of Army. Half of these participants had proven CAD by angiography test and the other ones were healthy as a control group. Fasting serum triglyceride was evaluated in all participants and postprandial TG was checked 4 hours after a standard meal. Obtained data were analyzed by SPSS ver. 13. Results: The results indicated that fasting TG and postprandial TG level were significantly higher in CAD patients (P-value=0.001). It was also shown evaluation of postprandial TG is more sensitive test than fasting TG in case of CAD patients. Conclusion: Our obtained results shown, evaluation of high level of postprandial TG is more reliable than fasting TG for patients whom suffer from CAD. PMID:27703285
Basol, Nursah; Celik, Atac; Karakus, Nevin; Ozturk, Sibel Demir; Ozsoy, Sibel Demir; Yigit, Serbulent
2014-01-01
Genetic polymorphism is a strong risk factor for coronary artery disease (CAD). In the present study, our aim was to evaluate angiotensin-converting enzyme (ACE) gene I/D polymorphism and interleukin-4 (IL-4) gene Intron 3 variable number of tandem repeat (VNTR) polymorphism in CAD. One hundred and twenty-four CAD patients and one hundred and twenty-three controls were enrolled. Genomic DNA was isolated and genotyped using polymerase chain reaction (PCR) analyses. The risk associated with inheriting the combined genotypes for the two polymorphisms were evaluated and it was found that the individuals who were P2P2-homozygous at IL-4 gene intron 3 VNTR and DD-homozygous at ACE gene I/D have a higher risk of developing CAD. Although, there is no correlation between IL4 VNTR polymorphism and ACE gene polymorphism and CAD, there is a strong association between CAD and co-existence of IL-4 VNTR and ACE gene polymorphisms in the Turkish population. Copyright © 2014 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.
Zimmermann, Moritz; Koller, Christina; Reymus, Marcel; Mehl, Albert; Hickel, Reinhard
2017-04-19
Resin-based CAD/CAM compound materials might be promising for single-tooth restorations. Insufficient clinical data are available for this new material class. The purpose of this study was to describe initial clinical in vivo results for indirect particle-filled composite resin CAD/CAM restorations after 24 months. Indirect particle-filled composite resin restorations were fabricated with a CAD/CAM method (CEREC Bluecam intraoral scanner, CEREC MCXL milling unit) by calibrated dental students. Forty-two partial crown restorations were seated adhesively in 30 patients with caries lesions or insufficient restorations (baseline). Strict inclusion criteria were defined for the patient collective. Follow-up evaluation comprised 40 restorations after 12 months and 33 restorations after 24 months. Evaluation criteria were modified FDI criteria with grades (1) to (5). Rating with FDI criteria (5) was defined as clinical failure. Statistical analysis was performed with Wilcoxon-Test (p < 0.05). The success rate of indirect particle-filled composite resin CAD/CAM restorations after 12 months was 95.0% with two debondings observed. The cumulative success rate for indirect particle-filled composite resin CAD/CAM restorations after 24 months was 85.7% with two tooth fractures and one debonding. Statistically significant differences were found for baseline and 24-month follow-up evaluation for anatomic form and marginal adaptation criterion examined in respect to FDI criteria guidelines (Wilcoxon-Test, p < 0.05). This study demonstrates particle-filled composite resin CAD/CAM restorations having a clinical success rate of 85.7% after 24 months. Adhesive bonding procedures need to be ensured carefully. A longer clinical evaluation period is necessary to draw further conclusions. © 2017 by the American College of Prosthodontists.
Ghayour-Mobarhan, Majid; Ayati, Nayyereh; Sahebkar, Amirhossein; Moohebati, Mohsen; Ayati, Narjes; Elyasi, Sepideh; Mohammadpour, Amir Houshang
2018-06-07
Previous studies have shown that Asymmetric Dimethyl Arginine (ADMA) is increased significantly during coronary artery diseases (CAD). However it is not clear either this increase is due to cardiovascular disease (CVD) risk factors or ADMA is increased independently in CAD. The aim of this study is to evaluate ADMA's plasma level as an independent biomarker in CADs. In current study a total of 165 subjects with no traditional CVD's RFs, who fulfilled the inclusion and exclusion criteria, were recruited; 55 CAD+ patients which had more than 50% stenosis (CAD+); 55 CAD- patients which had less than 50% stenosis in their coronary arteries (CAD-), based on their angiography record and 55 healthy individuals as controls. CAD+ patients were divided into three groups: single (SVD), double (2VD), and triple vessel (3VD) disease. Plasma level of soluble ADMA was measured with an enzyme-linked immono sorbent assay (ELISA) kit. No significant difference between ADMA's plasma levels was found between CAD+, CAD- and healthy groups. In addition ADMA's plasma levels was not significantly different between CAD+'s subgroups. The result of this study indicates no significant relation between ADMA's plasma levels and either presence or severity of coronary artery stenosis. Therefore, it is presumed that ADMA may not be an independent biomarker for CADs.
Godoy, Myrna C B; Kim, Tae Jung; White, Charles S; Bogoni, Luca; de Groot, Patricia; Florin, Charles; Obuchowski, Nancy; Babb, James S; Salganicoff, Marcos; Naidich, David P; Anand, Vikram; Park, Sangmin; Vlahos, Ioannis; Ko, Jane P
2013-01-01
The objective of our study was to evaluate the impact of computer-aided detection (CAD) on the identification of subsolid and solid lung nodules on thin- and thick-section CT. For 46 chest CT examinations with ground-glass opacity (GGO) nodules, CAD marks computed using thin data were evaluated in two phases. First, four chest radiologists reviewed thin sections (reader(thin)) for nodules and subsequently CAD marks (reader(thin) + CAD(thin)). After 4 months, the same cases were reviewed on thick sections (reader(thick)) and subsequently with CAD marks (reader(thick) + CAD(thick)). Sensitivities were evaluated. Additionally, reader(thick) sensitivity with assessment of CAD marks on thin sections was estimated (reader(thick) + CAD(thin)). For 155 nodules (mean, 5.5 mm; range, 4.0-27.5 mm)-74 solid nodules, 22 part-solid (part-solid nodules), and 59 GGO nodules-CAD stand-alone sensitivity was 80%, 95%, and 71%, respectively, with three false-positives on average (0-12) per CT study. Reader(thin) + CAD(thin) sensitivities were higher than reader(thin) for solid nodules (82% vs 57%, p < 0.001), part-solid nodules (97% vs 81%, p = 0.0027), and GGO nodules (82% vs 69%, p < 0.001) for all readers (p < 0.001). Respective sensitivities for reader(thick), reader(thick) + CAD(thick), reader(thick) + CAD(thin) were 40%, 58% (p < 0.001), and 77% (p < 0.001) for solid nodules; 72%, 73% (p = 0.322), and 94% (p < 0.001) for part-solid nodules; and 53%, 58% (p = 0.008), and 79% (p < 0.001) for GGO nodules. For reader(thin), false-positives increased from 0.64 per case to 0.90 with CAD(thin) (p < 0.001) but not for reader(thick); false-positive rates were 1.17, 1.19, and 1.26 per case for reader(thick), reader(thick) + CAD(thick), and reader(thick) + CAD(thin), respectively. Detection of GGO nodules and solid nodules is significantly improved with CAD. When interpretation is performed on thick sections, the benefit is greater when CAD marks are reviewed on thin rather than thick sections.
Chaudhry, Sundeep; Arena, Ross; Bhatt, Deepak L.; Verma, Subodh; Kumar, Naresh
2018-01-01
Purpose of review There is growing clinical interest for the use of cardiopulmonary exercise testing (CPET) to evaluate patients with or suspected coronary artery disease (CAD). With mounting evidence, this concise review with relevant teaching cases helps to illustrate how to integrate CPET data into real world patient care. Recent findings CPET provides a novel and purely physiological basis to identify cardiac dysfunction in symptomatic patients with both obstructive-CAD and nonobstructive-CAD (NO-CAD). In many cases, abnormal cardiac response on CPET may be the only objective evidence of potentially undertreated ischemic heart disease. When symptomatic patients have NO-CAD on coronary angiogram, they are still at increased risk for cardiovascular events. This problem appears to be more common in women than men and may warrant more aggressive risk factor modification. As the main intervention is lifestyle (diet, smoking cessation, exercise) and medical therapy (statins, angiotensin-converting enzyme inhibitors, beta-blockers), serial CPET testing enables close surveillance of cardiovascular function and is responsive to clinical status. Summary CPET can enhance outpatient evaluation and management of CAD. Diagnostically, it can help to identify physiologically significant obstructive-CAD and NO-CAD in patients with normal routine cardiac testing. CPET may be of particular value in symptomatic women with NO-CAD. Prognostically, precise quantification of improvements in exercise capacity may help to improve long-term lifestyle and medication adherence for this chronic condition. PMID:29240566
Misawa, Masashi; Kudo, Shin-Ei; Mori, Yuichi; Takeda, Kenichi; Maeda, Yasuharu; Kataoka, Shinichi; Nakamura, Hiroki; Kudo, Toyoki; Wakamura, Kunihiko; Hayashi, Takemasa; Katagiri, Atsushi; Baba, Toshiyuki; Ishida, Fumio; Inoue, Haruhiro; Nimura, Yukitaka; Oda, Msahiro; Mori, Kensaku
2017-05-01
Real-time characterization of colorectal lesions during colonoscopy is important for reducing medical costs, given that the need for a pathological diagnosis can be omitted if the accuracy of the diagnostic modality is sufficiently high. However, it is sometimes difficult for community-based gastroenterologists to achieve the required level of diagnostic accuracy. In this regard, we developed a computer-aided diagnosis (CAD) system based on endocytoscopy (EC) to evaluate cellular, glandular, and vessel structure atypia in vivo. The purpose of this study was to compare the diagnostic ability and efficacy of this CAD system with the performances of human expert and trainee endoscopists. We developed a CAD system based on EC with narrow-band imaging that allowed microvascular evaluation without dye (ECV-CAD). The CAD algorithm was programmed based on texture analysis and provided a two-class diagnosis of neoplastic or non-neoplastic, with probabilities. We validated the diagnostic ability of the ECV-CAD system using 173 randomly selected EC images (49 non-neoplasms, 124 neoplasms). The images were evaluated by the CAD and by four expert endoscopists and three trainees. The diagnostic accuracies for distinguishing between neoplasms and non-neoplasms were calculated. ECV-CAD had higher overall diagnostic accuracy than trainees (87.8 vs 63.4%; [Formula: see text]), but similar to experts (87.8 vs 84.2%; [Formula: see text]). With regard to high-confidence cases, the overall accuracy of ECV-CAD was also higher than trainees (93.5 vs 71.7%; [Formula: see text]) and comparable to experts (93.5 vs 90.8%; [Formula: see text]). ECV-CAD showed better diagnostic accuracy than trainee endoscopists and was comparable to that of experts. ECV-CAD could thus be a powerful decision-making tool for less-experienced endoscopists.
A CAD (Classroom Assessment Design) of a Computer Programming Course
ERIC Educational Resources Information Center
Hawi, Nazir S.
2012-01-01
This paper presents a CAD (classroom assessment design) of an entry-level undergraduate computer programming course "Computer Programming I". CAD has been the product of a long experience in teaching computer programming courses including teaching "Computer Programming I" 22 times. Each semester, CAD is evaluated and modified…
Shi, Zhenghao; Ma, Jiejue; Feng, Yaning; He, Lifeng; Suzuki, Kenji
2015-11-01
MTANN (Massive Training Artificial Neural Network) is a promising tool, which applied to eliminate false-positive for thoracic CT in recent years. In order to evaluate whether this method is feasible to eliminate false-positive of different CAD schemes, especially, when it is applied to commercial CAD software, this paper evaluate the performance of the method for eliminating false-positives produced by three different versions of commercial CAD software for lung nodules detection in chest radiographs. Experimental results demonstrate that the approach is useful in reducing FPs for different computer aided lung nodules detection software in chest radiographs.
Leal, Ermelindo C.; Martins, João; Voabil, Paula; Liberal, Joana; Chiavaroli, Carlo; Bauer, Jacques; Cunha-Vaz, José; Ambrósio, António F.
2010-01-01
OBJECTIVE Calcium dobesilate (CaD) has been used in the treatment of diabetic retinopathy in the last decades, but its mechanisms of action are not elucidated. CaD is able to correct the excessive vascular permeability in the retina of diabetic patients and in experimental diabetes. We investigated the molecular and cellular mechanisms underlying the protective effects of CaD against the increase in blood–retinal barrier (BRB) permeability induced by diabetes. RESEARCH DESIGN AND METHODS Wistar rats were divided into three groups: controls, streptozotocin-induced diabetic rats, and diabetic rats treated with CaD. The BRB breakdown was evaluated using Evans blue. The content or distribution of tight junction proteins (occludin, claudin-5, and zonula occluden-1 [ZO-1]), intercellular adhesion molecule-1 (ICAM-1), and p38 mitogen-activated protein kinase (p38 MAPK) was evaluated by Western blotting and immunohistochemistry. Leukocyte adhesion was evaluated in retinal vessels and in vitro. Oxidative stress was evaluated by the detection of oxidized carbonyls and tyrosine nitration. NF-κB activation was measured by enzyme-linked immunosorbent assay. RESULTS Diabetes increased the BRB permeability and retinal thickness. Diabetes also decreased occludin and claudin-5 levels and altered the distribution of ZO-1 and occludin in retinal vessels. These changes were inhibited by CaD treatment. CaD also inhibited the increase in leukocyte adhesion to retinal vessels or endothelial cells and in ICAM-1 levels, induced by diabetes or elevated glucose. Moreover, CaD decreased oxidative stress and p38 MAPK and NF-κB activation caused by diabetes. CONCLUSIONS CaD prevents the BRB breakdown induced by diabetes, by restoring tight junction protein levels and organization and decreasing leukocyte adhesion to retinal vessels. The protective effects of CaD are likely to involve the inhibition of p38 MAPK and NF-κB activation, possibly through the inhibition of oxidative/nitrosative stress. PMID:20627932
[The CAD-S, an instrument for the assessment of adaptation to divorce - separation].
Yárnoz Yaben, Sagrario; Comino González, Priscila
2010-02-01
The CAD-S, an Instrument for the Assessment of Adaptation to Divorce - Separation. This paper presents an instrument for the evaluation of the adaptation to divorce-separation. The CAD-S is a questionnaire created in Spanish, made up of 20 items whose aim is the evaluation of the family's adaptation to divorce-separation, using one of the parents as informant. Data were collected in four different samples of divorced persons and their children from different autonomous comunities from the Spanish state. 223 parents and 160 children from divorced families took part in this study. Four factors emerged, accounting for 52.39 percent of the total variance: psychological and emotional difficulties, conflict with the ex-partner, disposition to co-parentality, and negative outcomes of separation for children. The results suggest that CAD-S appears to be a reliable and valid instrument, with high internal consistency (Cronbach's alpha) and adequate construct validity supported by its relations with measures of satisfaction with life (SWLS), in the case of parents, and conduct problems (CBCL) for children.
Information fusion for diabetic retinopathy CAD in digital color fundus photographs.
Niemeijer, Meindert; Abramoff, Michael D; van Ginneken, Bram
2009-05-01
The purpose of computer-aided detection or diagnosis (CAD) technology has so far been to serve as a second reader. If, however, all relevant lesions in an image can be detected by CAD algorithms, use of CAD for automatic reading or prescreening may become feasible. This work addresses the question how to fuse information from multiple CAD algorithms, operating on multiple images that comprise an exam, to determine a likelihood that the exam is normal and would not require further inspection by human operators. We focus on retinal image screening for diabetic retinopathy, a common complication of diabetes. Current CAD systems are not designed to automatically evaluate complete exams consisting of multiple images for which several detection algorithm output sets are available. Information fusion will potentially play a crucial role in enabling the application of CAD technology to the automatic screening problem. Several different fusion methods are proposed and their effect on the performance of a complete comprehensive automatic diabetic retinopathy screening system is evaluated. Experiments show that the choice of fusion method can have a large impact on system performance. The complete system was evaluated on a set of 15,000 exams (60,000 images). The best performing fusion method obtained an area under the receiver operator characteristic curve of 0.881. This indicates that automated prescreening could be applied in diabetic retinopathy screening programs.
Computer-aided design development transition for IPAD environment
NASA Technical Reports Server (NTRS)
Owens, H. G.; Mock, W. D.; Mitchell, J. C.
1980-01-01
The relationship of federally sponsored computer-aided design/computer-aided manufacturing (CAD/CAM) programs to the aircraft life cycle design process, an overview of NAAD'S CAD development program, an evaluation of the CAD design process, a discussion of the current computing environment within which NAAD is developing its CAD system, some of the advantages/disadvantages of the NAAD-IPAD approach, and CAD developments during transition into the IPAD system are discussed.
ERIC Educational Resources Information Center
Nee, John G.; Kare, Audhut P.
1987-01-01
Explores several concepts in computer assisted design/computer assisted manufacturing (CAD/CAM). Defines, evaluates, reviews and compares advanced computer-aided geometric modeling and analysis techniques. Presents the results of a survey to establish the capabilities of minicomputer based-systems with the CAD/CAM packages evaluated. (CW)
Effect of ethanol-wet bonding with hydrophobic adhesive on caries-affected dentine.
Huang, Xueqing; Li, Li; Huang, Cui; Du, Xijin
2011-08-01
Frequently encountered in clinical practice, caries-affected dentine (CAD) is the most challenging bonding substrate. This study evaluated the effect of ethanol-wet bonding with hydrophobic adhesive to sound dentine and to CAD. In the control groups, prepared sound dentine and CAD were bonded with Adper Single Bond 2 using a traditional water-wet bonding technique. In the experimental groups, the specimens were treated as follows: Group 1, rinsed with stepwise ethanol dehydration; Group 2, immersion in 100% ethanol, three times, for 20 s each time; and Group 3, immersion in 100% ethanol for 20 s. Microtensile bond strength (μTBS) testing was used to evaluate the effects of the different protocols on bonding. The microhardness of debonded dentine surfaces was measured to ensure the presence of CAD. Interfacial nanoleakage was evaluated by field-emission scanning electron microscopy. Treatment significantly improved the μTBS in CAD in Groups 1 and 2, but had no effect on Group 3. Conversely, treatment significantly reduced the μTBS in sound dentine in Groups 2 and 3, but had no effect in Group 1. The presence of nanoleakage varied with the ethanol-wet protocol used. In conclusion, ethanol-wet bonding can potentially improve bond efficacy to CAD when an appropriate protocol is used. © 2011 Eur J Oral Sci.
A computer-aided detection (CAD) system with a 3D algorithm for small acute intracranial hemorrhage
NASA Astrophysics Data System (ADS)
Wang, Ximing; Fernandez, James; Deshpande, Ruchi; Lee, Joon K.; Chan, Tao; Liu, Brent
2012-02-01
Acute Intracranial hemorrhage (AIH) requires urgent diagnosis in the emergency setting to mitigate eventual sequelae. However, experienced radiologists may not always be available to make a timely diagnosis. This is especially true for small AIH, defined as lesion smaller than 10 mm in size. A computer-aided detection (CAD) system for the detection of small AIH would facilitate timely diagnosis. A previously developed 2D algorithm shows high false positive rates in the evaluation based on LAC/USC cases, due to the limitation of setting up correct coordinate system for the knowledge-based classification system. To achieve a higher sensitivity and specificity, a new 3D algorithm is developed. The algorithm utilizes a top-hat transformation and dynamic threshold map to detect small AIH lesions. Several key structures of brain are detected and are used to set up a 3D anatomical coordinate system. A rule-based classification of the lesion detected is applied based on the anatomical coordinate system. For convenient evaluation in clinical environment, the CAD module is integrated with a stand-alone system. The CAD is evaluated by small AIH cases and matched normal collected in LAC/USC. The result of 3D CAD and the previous 2D CAD has been compared.
Sonmez, Nesrin; Gultekin, Pinar; Turp, Volkan; Akgungor, Gokhan; Sen, Deniz; Mijiritsky, Eitan
2018-01-08
Polymer infiltrated ceramics and nano-ceramic resins are the new restorative materials which have been developed in order to enhance the adverse properties of glass-matrix ceramics and resin composites. The aim of the present in vitro study was to evaluate the characteristics of various CAD/CAM materials through mechanical, microstructural, and SEM analysis. Five test groups (n = 22) were formed by using the indicated CAD/CAM blocks: VITA Enamic (VITA Zahnfabrik), Lava Ultimate (3 M ESPE), IPS e.max CAD (Ivoclar Vivadent), IPS Empress CAD (Ivoclar Vivadent), and VITA Mark II (VITA Zahnfabrik). Two specimens from each test group were used for XRD and EDS analysis. Remaining samples were divided into two subgroups (n = 10). One subgroup specimens were thermocycled (5 °C to 55 °C, 30s, 10,000 cycles) whereas the other were not. All of the specimens were evaluated in terms of flexural strength, Vickers hardness, and fracture toughness. Results were statistically analyzed using two-way ANOVA, one-way ANOVA, Tukey's HSD, and Student's t tests (α = .05). Fractured specimens were evaluated using SEM. The highest Vickers microhardness value was found for VITA Mark II (p < .001), however flexural strength and fracture toughness results were lowest conversely (p < .05). IPS e.max CAD was found to have the highest flexural strength (p < .001). Fracture toughness of IPS e.max CAD was also higher than other tested block materials (p < .001). Lava Ultimate and VITA Enamic's mechanical properties were affected negatively from thermocycling (p < .05). Microhardness, flexural strength, and fracture toughness values of Lava Ultimate and VITA Enamic were found to be similar to VITA Mark II and IPS Empress CAD groups. It should be realised that simulated aging process seem to affect ceramic-polymer composite materials more significantly than glass ceramics.
Oh, Tae Jung; Ahn, Chang Ho; Kim, Bo-Rahm; Kim, Kyoung Min; Moon, Jae Hoon; Lim, Soo; Park, Kyong Soo; Lim, Cheong; Jang, HakChul; Choi, Sung Hee
2017-07-20
A previous genome-wide association study showed that a genetic variant of sortilin was associated with the risk of coronary artery disease (CAD). However, the role of circulating sortilin is still unknown. We investigated the potential role of plasma sortilin as a biomarker for CAD and diabetes mellitus. We enrolled statin-naïve subjects with CAD (n = 31) who underwent coronary artery bypass surgery and control subjects (n = 116) who were free from CAD as evaluated by coronary CT angiography. The presence of diabetes mellitus was evaluated and plasma sortilin levels were measured with a commercial ELISA kit. Plasma sortilin levels were higher in subjects with CAD and subjects with diabetes mellitus than in those without CAD or diabetes mellitus. Subjects in the highest sortilin tertile group were older and had higher glucose and HbA1c levels, but lipid profiles in the three tertile groups were comparable. Multivariable logistic regression analysis revealed that sortilin levels were independently associated with CAD. In addition, the receiver operating characteristic curve analysis showed that plasma sortilin levels could identify the presence of CAD or diabetes mellitus. Elevated circulating sortilin levels are associated with CAD and diabetes mellitus and can be used as a biomarker of both diseases in statin-naïve subjects.
Performance evaluation of NASA/KSC CAD/CAE graphics local area network
NASA Technical Reports Server (NTRS)
Zobrist, George
1988-01-01
This study had as an objective the performance evaluation of the existing CAD/CAE graphics network at NASA/KSC. This evaluation will also aid in projecting planned expansions, such as the Space Station project on the existing CAD/CAE network. The objectives were achieved by collecting packet traffic on the various integrated sub-networks. This included items, such as total number of packets on the various subnetworks, source/destination of packets, percent utilization of network capacity, peak traffic rates, and packet size distribution. The NASA/KSC LAN was stressed to determine the useable bandwidth of the Ethernet network and an average design station workload was used to project the increased traffic on the existing network and the planned T1 link. This performance evaluation of the network will aid the NASA/KSC network managers in planning for the integration of future workload requirements into the existing network.
An Evaluation of Internet-Based CAD Collaboration Tools
ERIC Educational Resources Information Center
Smith, Shana Shiang-Fong
2004-01-01
Due to the now widespread use of the Internet, most companies now require computer aided design (CAD) tools that support distributed collaborative design on the Internet. Such CAD tools should enable designers to share product models, as well as related data, from geographically distant locations. However, integrated collaborative design…
Implementing a new curriculum for computer-assisted restorations in prosthetic dentistry.
Schweyen, R; Beuer, F; Bochskanl, M; Hey, J
2018-05-01
Computer-aided design/computer-aided manufacturing (CAD/CAM) of fixed prosthetic restorations has gained popularity in the last decade. However, this field of dentistry has not been integrated in the dental curriculum at most universities. According to the method of Kern, a curriculum was designed and established on a voluntary basis in the prosthetic education of a German dental school. The success of the implementation was measured by evaluation carried out by the participants on a visual analogue scale. Furthermore, the clinical performance of the fabricated restorations was evaluated. Ninety-four percent of all students participated in the CAD/CAM curriculum indicating considerable interest. Nearly half of all students used the acquired knowledge to design crowns for their patients. All restorations fabricated by participants of the new CAD/CAM programme showed good clinical performance. By phasing-in the CAD/CAM training programme, independent CAD/CAM-based fabrication of all-ceramic crowns increased student's self-confidence in tooth preparation. A tendency was found that students using CAD/CAM technology prepared more teeth than their fellow students who did not use CAD/CAM technology. Further studies are required to investigate the influence of independent CAD/CAM-based single-crown fabrication on the quality of the preparation. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Ortaç Ersoy, Ebru; Fırat, Hikmet; Akaydın, Sevgi; Özkan, Yeşim; Durusu, Mine; Darılmaz Yüce, Gülbahar; Ergün, Recai; Topeli, Arzu; Ardıç, Sadık
2014-01-01
Obstructive sleep apnea (OSA) is associated with cardiovascular morbidity and mortality. Deficiency of nitric oxide (NO) and plasma levels of homocystein have been implicated in the pathogenesis of cardiovascular disease. OSA results in oxygen desaturation and arousal from sleep. Free oxygen radicals can be produced by hypoxia-reoxygenation. To test for the hypothesis that OSA is associated with cardiovascular morbidity, we investigated levels of homocystein, NO and total antioxidant capacity in OSA patients with and without coronary artery disease (CAD) in comparison with normal subjects and patients with CAD without OSA. Polysomnography was performed in 27 patients who had a myocardial infarction and in 25 patients without evidence of CAD. Patients were grouped according their polysomnography results as OSA with CAD (group 1), OSA without CAD (group 2), CAD (group 3), and normal (group 4) . Levels of homocystein, NO and total antioxidant capacity were determined after an overnight fasting. Data were analysed with parametric and non parametric statistical tests. According to apnea-hypopnea index (AHI) 44.4% of CAD patients were OSA. After polysomnographic evaluation, the patients were re-distributed as follows: OSA with CAD (n= 12), OSA without CAD (n= 14), CAD (n= 15), and normal (n= 11). Homocystein levels were higher in 3 groups compared to controls. AHI, MDI and desaturation time was higher in three -vessel disease compared to one and two- vessel diseases (p< 0.05). NO levels were correlated with the period of oxygen desaturation (r: -0.45, p= 0.031). The antioxidant capacity did not differ between OSA and healthy groups. OSA is frequent in CAD. AHI, MDI and desaturation time are higher in patients with severe CAD. It is important to evaluate OSA patients for CAD.
Evaluating the Learning Process of Mechanical CAD Students
ERIC Educational Resources Information Center
Hamade, R. F.; Artail, H. A.; Jaber, M. Y.
2007-01-01
There is little theoretical or experimental research on how beginner-level trainees learn CAD skills in formal training sessions. This work presents findings on how trainees develop their skills in utilizing a solid mechanical CAD tool (Pro/Engineer version 2000i[squared] and later version Wildfire). Exercises at the beginner and intermediate…
Vojdani, Mahroo; Torabi, Kianoosh; Atashkar, Berivan; Heidari, Hossein; Torabi Ardakani, Mahshid
2016-12-01
Marginal fitness is the most important criteria for evaluation of the clinical acceptability of a cast restoration. Marginal gap which is due to cement solubility and plaque retention is potentially detrimental to both tooth and periodontal tissues. This in vitro study aimed to evaluate the marginal and internal fit of cobalt- chromium (Co-Cr) copings fabricated by two different CAD/CAM systems: (CAD/ milling and CAD/ Ceramill Sintron). We prepared one machined standard stainless steel master model with following dimensions: 7 mm height, 5mm diameter, 90˚ shoulder marginal finish line with 1 mm width, 10˚ convergence angle and anti-rotational surface on the buccal aspect of the die. There were 10 copings produced from hard presintered Co-Cr blocks according to CAD/ Milling technique and ten copings from soft non- presintered Co-Cr blocks according to CAD/ Ceramill Sintron technique. Marginal and internal accuracies of copings were documented by the replica technique. Replicas were examined at ten reference points under a digital microscope (230X). The Student's t-test was used for statistical analysis. p < 0.001 was considered significant. Statistically significant differences existed between the groups ( p < 0.001). The CAD/milling group (hard copings) had a mean marginal discrepancy (MD) of 104 µm, axial discrepancy (AD) of 23 µm and occlusal discrepancy of 130 µm. For CAD/ Ceramill Sintron group, these values were 195 µm (MD), 46 µm (AD), and 232 µm (OD). Internal total discrepancy (ITD) for the CAD/milling group was 77 µm, whereas for the CAD/Ceramill Sintron group was 143 µm. Hard presintered Co-Cr copings had significantly higher marginal and internal accuracies compared to the soft non-presintered copings.
Ye, Hongqiang; Li, Xinxin; Wang, Guanbo; Kang, Jing; Liu, Yushu; Sun, Yuchun; Zhou, Yongsheng
2018-02-15
To investigate a computer-aided design/computer-aided manufacturing (CAD/CAM) process for producing one-piece removable partial dentures (RPDs) and to evaluate their fits in vitro. A total of 15 one-piece RPDs were designed using dental CAD and reverse engineering software and then fabricated with polyetheretherketone (PEEK) using CAM. The gaps between RPDs and casts were measured and compared with traditional cast framework RPDs. Gaps were lower for one-piece PEEK RPDs compared to traditional RPDs. One-piece RPDs can be manufactured by CAD/CAM, and their fits were better than those of traditional RPDs.
Role of nuclear cardiology in evaluating the total ischemic burden in coronary artery disease
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beller, G.A.
1987-03-09
Goals of exercise radionuclide imaging are to: enhance sensitivity, specificity and predictive value of coronary artery disease (CAD) detection; noninvasively assess extent and severity of functionally significant CAD; determine prognosis so that specific therapeutic strategies can be more rationally implemented; detect silent ischemia in asymptomatic subjects or in patients with known CAD with a higher degree of specificity than can be accomplished by electrocardiogram stress testing alone; evaluate the response to therapeutic interventions aimed at enhancing coronary blood flow. Two major radionuclide techniques are currently used in evaluating the total ischemic burden in patients with CAD. These are myocardial perfusionmore » imaging with either thallium-201 or rubidium-82, and radionuclide angiography performed after administration of technetium-99m. Areas of diminished thallium-201 activity on early postexercise images are abnormal and represent either areas of stress-induced ischemia or myocardial scar. To differentiate between the two, delayed images are obtained to determine if the initial postexercise defect either persists or demonstrates redistribution. Defects demonstrating redistribution represent transient ischemia, whereas areas of previous infarction or scar usually appear as persistent defects. Patients with left main or 3-vessel CAD usually show multiple thallium-201 redistribution defects in more than 1 vascular supply region, a phenomenon often associated with abnormal lung thallium-201 uptake.« less
Prakashini, K; Babu, Satish; Rajgopal, K V; Kokila, K Raja
2016-01-01
To determine the overall performance of an existing CAD algorithm with thin-section computed tomography (CT) in the detection of pulmonary nodules and to evaluate detection sensitivity at a varying range of nodule density, size, and location. A cross-sectional prospective study was conducted on 20 patients with 322 suspected nodules who underwent diagnostic chest imaging using 64-row multi-detector CT. The examinations were evaluated on reconstructed images of 1.4 mm thickness and 0.7 mm interval. Detection of pulmonary nodules, initially by a radiologist of 2 years experience (RAD) and later by CAD lung nodule software was assessed. Then, CAD nodule candidates were accepted or rejected accordingly. Detected nodules were classified based on their size, density, and location. The performance of the RAD and CAD system was compared with the gold standard that is true nodules confirmed by consensus of senior RAD and CAD together. The overall sensitivity and false-positive (FP) rate of CAD software was calculated. Of the 322 suspected nodules, 221 were classified as true nodules on the consensus of senior RAD and CAD together. Of the true nodules, the RAD detected 206 (93.2%) and 202 (91.4%) by the CAD. CAD and RAD together picked up more number of nodules than either CAD or RAD alone. Overall sensitivity for nodule detection with the CAD program was 91.4%, and FP detection per patient was 5.5%. The CAD showed comparatively higher sensitivity for nodules of size 4-10 mm (93.4%) and nodules in hilar (100%) and central (96.5%) location when compared to RAD's performance. CAD performance was high in detecting pulmonary nodules including the small size and low-density nodules. CAD even with relatively high FP rate, assists and improves RAD's performance as a second reader, especially for nodules located in the central and hilar region and for small nodules by saving RADs time.
Reliability and validity of the AutoCAD software method in lumbar lordosis measurement
Letafatkar, Amir; Amirsasan, Ramin; Abdolvahabi, Zahra; Hadadnezhad, Malihe
2011-01-01
Objective The aim of this study was to determine the reliability and validity of the AutoCAD software method in lumbar lordosis measurement. Methods Fifty healthy volunteers with a mean age of 23 ± 1.80 years were enrolled. A lumbar lateral radiograph was taken on all participants, and the lordosis was measured according to the Cobb method. Afterward, the lumbar lordosis degree was measured via AutoCAD software and flexible ruler methods. The current study is accomplished in 2 parts: intratester and intertester evaluations of reliability as well as the validity of the flexible ruler and software methods. Results Based on the intraclass correlation coefficient, AutoCAD's reliability and validity in measuring lumbar lordosis were 0.984 and 0.962, respectively. Conclusions AutoCAD showed to be a reliable and valid method to measure lordosis. It is suggested that this method may replace those that are costly and involve health risks, such as radiography, in evaluating lumbar lordosis. PMID:22654681
Reliability and validity of the AutoCAD software method in lumbar lordosis measurement.
Letafatkar, Amir; Amirsasan, Ramin; Abdolvahabi, Zahra; Hadadnezhad, Malihe
2011-12-01
The aim of this study was to determine the reliability and validity of the AutoCAD software method in lumbar lordosis measurement. Fifty healthy volunteers with a mean age of 23 ± 1.80 years were enrolled. A lumbar lateral radiograph was taken on all participants, and the lordosis was measured according to the Cobb method. Afterward, the lumbar lordosis degree was measured via AutoCAD software and flexible ruler methods. The current study is accomplished in 2 parts: intratester and intertester evaluations of reliability as well as the validity of the flexible ruler and software methods. Based on the intraclass correlation coefficient, AutoCAD's reliability and validity in measuring lumbar lordosis were 0.984 and 0.962, respectively. AutoCAD showed to be a reliable and valid method to measure lordosis. It is suggested that this method may replace those that are costly and involve health risks, such as radiography, in evaluating lumbar lordosis.
Nissen, Louise; Winther, Simon; Isaksen, Christin; Ejlersen, June Anita; Brix, Lau; Urbonaviciene, Grazina; Frost, Lars; Madsen, Lene Helleskov; Knudsen, Lars Lyhne; Schmidt, Samuel Emil; Holm, Niels Ramsing; Maeng, Michael; Nyegaard, Mette; Bøtker, Hans Erik; Bøttcher, Morten
2016-05-26
Coronary computed tomography angiography (CCTA) is an established method for ruling out coronary artery disease (CAD). Most patients referred for CCTA do not have CAD and only approximately 20-30 % of patients are subsequently referred to further testing by invasive coronary angiography (ICA) or non-invasive perfusion evaluation due to suspected obstructive CAD. In cases with severe calcifications, a discrepancy between CCTA and ICA often occurs, leading to the well-described, low-diagnostic specificity of CCTA. As ICA is cost consuming and involves a risk of complications, an optimized algorithm would be valuable and could decrease the number of ICAs that do not lead to revascularization. The primary objective of the Dan-NICAD study is to determine the diagnostic accuracy of cardiac magnetic resonance imaging (CMRI) and myocardial perfusion scintigraphy (MPS) as secondary tests after a primary CCTA where CAD could not be ruled out. The secondary objective includes an evaluation of the diagnostic precision of an acoustic technology that analyses the sound of coronary blood flow. It may potentially provide better stratification prior to CCTA than clinical risk stratification scores alone. Dan-NICAD is a multi-centre, randomised, cross-sectional trial, which will include approximately 2,000 patients without known CAD, who were referred to CCTA due to a history of symptoms suggestive of CAD and a low-risk to intermediate-risk profile, as evaluated by a cardiologist. Patient interview, sound recordings, and blood samples are obtained in connection with the CCTA. All patients with suspected obstructive CAD by CCTA are randomised to either stress CMRI or stress MPS, followed by ICA with fractional flow reserve (FFR) measurements. Obstructive CAD is defined as an FFR below 0.80 or as high-grade stenosis (>90 % diameter stenosis) by visual assessment. Diagnostic performance is evaluated as sensitivity, specificity, predictive values, likelihood ratios, and C statistics. Enrolment commenced in September 2014 and is expected to be complete in May 2016. Dan-NICAD is designed to assess whether a secondary perfusion examination after CCTA could safely reduce the number of ICAs where revascularization is not required. The results are expected to add knowledge about the optimal algorithm for diagnosing CAD. Clinicaltrials.gov identifier, NCT02264717 . Registered on 26 September 2014.
Gadolinium Enhanced MR Coronary Vessel Wall Imaging at 3.0 Tesla.
Kelle, Sebastian; Schlendorf, Kelly; Hirsch, Glenn A; Gerstenblith, Gary; Fleck, Eckart; Weiss, Robert G; Stuber, Matthias
2010-10-11
Purpose. We evaluated the influence of the time between low-dose gadolinium (Gd) contrast administration and coronary vessel wall enhancement (LGE) detected by 3T magnetic resonance imaging (MRI) in healthy subjects and patients with coronary artery disease (CAD). Materials and Methods. Four healthy subjects (4 men, mean age 29 ± 3 years and eleven CAD patients (6 women, mean age 61 ± 10 years) were studied on a commercial 3.0 Tesla (T) whole-body MR imaging system (Achieva 3.0 T; Philips, Best, The Netherlands). T1-weighted inversion-recovery coronary magnetic resonance imaging (MRI) was repeated up to 75 minutes after administration of low-dose Gadolinium (Gd) (0.1 mmol/kg Gd-DTPA). Results. LGE was seen in none of the healthy subjects, however in all of the CAD patients. In CAD patients, fifty-six of 62 (90.3%) segments showed LGE of the coronary artery vessel wall at time-interval 1 after contrast. At time-interval 2, 34 of 42 (81.0%) and at time-interval 3, 29 of 39 evaluable segments (74.4%) were enhanced. Conclusion. In this work, we demonstrate LGE of the coronary artery vessel wall using 3.0 T MRI after a single, low-dose Gd contrast injection in CAD patients but not in healthy subjects. In the majority of the evaluated coronary segments in CAD patients, LGE of the coronary vessel wall was already detectable 30-45 minutes after administration of the contrast agent.
ERIC Educational Resources Information Center
Franken, Ken; And Others
A multidisciplinary research team was assembled to review existing computer-aided drafting (CAD) systems for the purpose of enabling staff in the Design Drafting Department at Linn Technical College (Missouri) to select the best system out of the many CAD systems in existence. During the initial stage of the evaluation project, researchers…
Comparison of denture tooth movement between CAD-CAM and conventional fabrication techniques.
Goodacre, Brian J; Goodacre, Charles J; Baba, Nadim Z; Kattadiyil, Mathew T
2018-01-01
Data comparing the denture tooth movement of computer-aided design and computer-aided manufacturing (CAD-CAM) and conventional denture processing techniques are lacking. The purpose of this in vitro study was to compare the denture tooth movement of pack-and-press, fluid resin, injection, CAD-CAM-bonded, and CAD-CAM monolithic techniques for fabricating dentures to determine which process produces the most accurate and reproducible prosthesis. A total of 50 dentures were evaluated, 10 for each of the 5 groups. A master denture was fabricated and milled from prepolymerized poly(methyl methacrylate). For the conventional processing techniques (pack-and-press, fluid resin, and injection) a polyvinyl siloxane putty mold of the master denture was made in which denture teeth were placed and molten wax injected. The cameo surface of each wax-festooned denture was laser scanned, resulting in a standard tessellation language (STL) format file. The CAD-CAM dentures included 2 subgroups: CAD-CAM-bonded teeth in which the denture teeth were bonded into the milled denture base and CAD-CAM monolithic teeth in which the denture teeth were milled as part of the denture base. After all specimens had been fabricated, they were hydrated for 24 hours, and the cameo surface laser scanned. The preprocessing and postprocessing scan files of each denture were superimposed using surface-matching software. Measurements were made at 64 locations, allowing evaluation of denture tooth movement in a buccal, lingual, mesial-distal, and occlusal direction. The use of median and interquartile range values was used to assess accuracy and reproducibility. Levene and Kruskal-Wallis analyses of variance were used to evaluate differences between processing techniques (α=.05). The CAD-CAM monolithic technique was the most accurate, followed by fluid resin, CAD-CAM-bonded, pack-and-press, and injection. CAD-CAM monolithic technique was the most reproducible, followed by pack-and-press, CAD-CAM-bonded, injection, and fluid resin. Techniques involving compression during processing showed increased positive occlusal tooth movement compared with techniques not involving compression. CAD-CAM monolithic dentures produced the best combination of accuracy and reproducibility of the tested techniques. The results from this study demonstrate that varying amounts of tooth movement can be expected depending on the processing technique. However, the clinical significance of these differences is unknown. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Skaane, Per; Kshirsagar, Ashwini; Hofvind, Solveig; Jahr, Gunnar; Castellino, Ronald A
2012-04-01
Double reading improves the cancer detection rate in mammography screening. Single reading with computer-aided detection (CAD) has been considered to be an alternative to double reading. Little is known about the potential benefit of CAD in breast cancer screening with double reading. To compare prospective independent double reading of screen-film (SFM) and full-field digital (FFDM) mammography in population-based screening with retrospective standalone CAD performance on the baseline mammograms of the screen-detected cancers and subsequent cancers diagnosed during the follow-up period. The study had ethics committee approval. A 5-point rating scale for probability of cancer was used for 23,923 (SFM = 16,983; FFDM = 6940) screening mammograms. Of 208 evaluable cancers, 104 were screen-detected and 104 were subsequent (44 interval and 60 next screening round) cancers. Baseline mammograms of subsequent cancers were retrospectively classified in consensus without information about cancer location, histology, or CAD prompting as normal, non-specific minimal signs, significant minimal signs, and false-negatives. The baseline mammograms of the screen-detected cancers and subsequent cancers were evaluated by CAD. Significant minimal signs and false-negatives were considered 'actionable' and potentially diagnosable if correctly prompted by CAD. CAD correctly marked 94% (98/104) of the baseline mammograms of the screen-detected cancers (SFM = 95% [61/64]; FFDM = 93% [37/40]), including 96% (23/24) of those with discordant interpretations. Considering only those baseline examinations of subsequent cancers prospectively interpreted as normal and retrospectively categorized as 'actionable', CAD input at baseline screening had the potential to increase the cancer detection rate from 0.43% to 0.51% (P = 0.13); and to increase cancer detection by 16% ([104 + 17]/104) and decrease interval cancers by 20% (from 44 to 35). CAD may have the potential to increase cancer detection by up to 16%, and to reduce the number of interval cancers by up to 20% in SFM and FFDM screening programs using independent double reading with consensus review. The influence of true- and false-positive CAD marks on decision-making can, however, only be evaluated in a prospective clinical study.
Turnkey CAD/CAM selection and evaluation
NASA Technical Reports Server (NTRS)
Moody, T.
1980-01-01
The methodology to be followed in evaluating and selecting a computer system for manufacturing applications is discussed. Main frames and minicomputers are considered. Benchmark evaluations, demonstrations, and contract negotiations are discussed.
Discoloration of various CAD/CAM blocks after immersion in coffee.
Lauvahutanon, Sasipin; Shiozawa, Maho; Takahashi, Hidekazu; Iwasaki, Naohiko; Oki, Meiko; Finger, Werner J; Arksornnukit, Mansuang
2017-02-01
This study evaluated color differences (Δ E s) and translucency parameter changes (Δ TP s) of various computer-aided design/computer-aided manufacturing (CAD/CAM) blocks after immersion in coffee. Eight CAD/CAM blocks and four restorative composite resins were evaluated. The CIE L * a * b * values of 2.0 mm thick disk-shaped specimens were measured using the spectrophotometer on white and black backgrounds ( n = 6). The Δ E s and Δ TP s of one day, one week, and one month immersion in coffee or water were calculated. The values of each material were analyzed by two-way ANOVA and Tukey's multiple comparisons (α = 0.05). The Δ E s after prophylaxis paste polishing of 1 month coffee immersion specimens, water sorption and solubility were also evaluated. After one month in coffee, Δ E s of CAD/CAM composite resin blocks and restorative composites ranged from 1.6 to 3.7 and from 2.1 to 7.9, respectively, and Δ TP s decreased. The ANOVA of Δ E s and Δ TP s revealed significant differences in two main factors, immersion periods and media, and their interaction except for Δ E s of TEL (Telio CAD, Ivoclar Vivadent). The Δ E s significantly decreased after prophylaxis polishing except GRA (Gradia Block, GC). There was no significant correlation between Δ E s and water sorption or solubility in water. The Δ E s of CAD/CAM blocks after immersion in coffee varied among products and were comparable to those of restorative composite resins. The discoloration of CAD/CAM composite resin blocks could be effectively removed with prophylaxis paste polishing, while that of some restorative composites could not be removed.
Kim, Yong-Hyun; Shim, Wan-Joo; Kim, Myung-A; Hong, Kyung-Soon; Shin, Mi-Seung; Park, Seong-Mi; Cho, Kyoung Im; Kim, Mina; Kim, Sihun; Kim, Hak-Lyoung; Yoon, Hyun-Ju; Na, Jin-Oh; Kim, Sung-Eun
2016-06-01
Pretest probability (PTP) and an exercise treadmill test (ETT) are recommended for the initial evaluation of possible coronary artery disease (CAD), but the applicability of these tests in Korean women has not been evaluated. Korean women with PTP, ETT, and invasive coronary angiography results were enrolled. Across all PTP levels, PTP and ETT statistics were evaluated and independent CAD predictors obtained. Of the 335 patients (mean age 58.0 ± 10.2 years), 99 and 236 were in the low (LPTP) and intermediate PTP (IPTP) groups, respectively. The observed prevalence of CAD was significantly lower than the PTP. (7.1% vs. 9.1 ± 4.9% in LPTP, p < 0.001; 23.3% vs. 33.0 ± 15.1% in IPTP, p < 0.001) The ETT's sensitivity and positive predictive values (PPVs) appeared lower than previously reported (LPTP: 42.9% and 16.7%; IPTP: 61.8% and 37.0%), whereas the negative predictive values (NPVs) were higher (LPTP: 95.1%; IPTP: 85.4%). After multivariate adjustments, positive ETT (odds ratio 3.276, 95% confidence interval 1.643-6.532, p = 0.001) independently predicted the presence of CAD, but the PTP showed only marginal predictability (odds ratio 1.019, 95% confidence interval 0.998-1.041, p = 0.069). In Korean women, the observed prevalence of CAD was lower than the PTP, and PTP showed only marginal CAD predictability. Although a positive ETT independently predicted CAD, the ETT showed lower sensitivity and PPVs than previously reported. Despite the limited value of PTP and ETT, the high NPVs of ETT appear useful for saving patients from unnecessary further examinations.
Min, James K; Shaw, Leslee J; Berman, Daniel S; Gilmore, Amanda; Kang, Ning
2008-09-15
Multidetector coronary computed tomographic angiography (CCTA) demonstrates high accuracy for the detection and exclusion of coronary artery disease (CAD) and predicts adverse prognosis. To date, opportunity costs relating the clinical and economic outcomes of CCTA compared with other methods of diagnosing CAD, such as myocardial perfusion single-photon emission computed tomography (SPECT), remain unknown. An observational, multicenter, patient-level analysis of patients without known CAD who underwent CCTA or SPECT was performed. Patients who underwent CCTA (n = 1,938) were matched to those who underwent SPECT (n = 7,752) on 8 demographic and clinical characteristics and 2 summary measures of cardiac medications and co-morbidities and were evaluated for 9-month expenditures and clinical outcomes. Adjusted total health care and CAD expenditures were 27% (p <0.001) and 33% (p <0.001) lower, respectively, for patients who underwent CCTA compared with those who underwent SPECT, by an average of $467 (95% confidence interval $99 to $984) for CAD expenditures per patient. Despite lower total health care expenditures for CCTA, no differences were observed for rates of adverse cardiovascular events, including CAD hospitalizations (4.2% vs 4.1%, p = NS), CAD outpatient visits (17.4% vs 13.3%, p = NS), myocardial infarction (0.4% vs 0.6%, p = NS), and new-onset angina (3.0% vs 3.5%, p = NS). Patients without known CAD who underwent CCTA, compared with matched patients who underwent SPECT, incurred lower overall health care and CAD expenditures while experiencing similarly low rates of CAD hospitalization, outpatient visits, myocardial infarction, and angina. In conclusion, these data suggest that CCTA may be a cost-efficient alternative to SPECT for the initial coronary evaluation of patients without known CAD.
Detection of breast cancer with full-field digital mammography and computer-aided detection.
The, Juliette S; Schilling, Kathy J; Hoffmeister, Jeffrey W; Friedmann, Euvondia; McGinnis, Ryan; Holcomb, Richard G
2009-02-01
The purpose of this study was to evaluate computer-aided detection (CAD) performance with full-field digital mammography (FFDM). CAD (Second Look, version 7.2) was used to evaluate 123 cases of breast cancer detected with FFDM (Senographe DS). Retrospectively, CAD sensitivity was assessed using breast density, mammographic presentation, histopathology results, and lesion size. To determine the case-based false-positive rate, patients with four standard views per case were included in the study group. Eighteen unilateral mammography examinations with nonstandard views were excluded, resulting in a sample of 105 bilateral cases. CAD detected 115 (94%) of 123 cancer cases: six of six (100%) in fatty breasts, 63 of 66 (95%) in breasts containing scattered fibroglandular densities, 43 of 46 (93%) in heterogeneously dense breasts, and three of five (60%) in extremely dense breasts. CAD detected 93% (41/44) of cancers manifesting as calcifications, 92% (57/62) as masses, and 100% (17/17) as mixed masses and calcifications. CAD detected 94% of the invasive ductal carcinomas (n = 63), 100% of the invasive lobular carcinomas (n = 7), 91% of the other invasive carcinomas (n = 11), and 93% of the ductal carcinomas in situ (n = 42). CAD sensitivity for cancers 1-10 mm (n = 55) was 89%; 11-20 mm (n = 37), 97%; 21-30 mm (n = 16), 100%; and larger than 30 mm (n = 15), 93%. The CAD false-positive rate was 2.3 marks per four-image case. CAD with FFDM showed a high sensitivity in identifying cancers manifesting as calcifications and masses. Sensitivity was maintained in cancers with lower mammographic sensitivity, including invasive lobular carcinomas and small neoplasms (1-20 mm). CAD with FFDM should be effective in assisting radiologists with earlier detection of breast cancer. Future studies are needed to assess CAD accuracy in larger populations.
Incorporation of CAD/CAM Restoration Into Navy Dentistry
2017-09-26
CAD/CAM Computer-aided design /Computer-assisted manufacturing CDT Common Dental Terminology DENCAS Dental Common Access System DTF Dental...to reduce avoidable dental emergencies for deployed sailors and marines. Dental Computer-aided design /Computer-assisted manufacturing (CAD/CAM...report will review and evaluate the placement rate by Navy dentists of digitally fabricated in-office ceramic restorations compared to traditional direct
ERIC Educational Resources Information Center
Wilkerson, Joyce A.; Elkins, Susan A.
This qualitative case study assessed web-based instruction in a computer-aided design/computer-assisted manufacturing (CAD/CAM) course designed for workforce development. The study examined students' and instructors' experience in a CAD/CAM course delivered exclusively on the Internet, evaluating course content and delivery, clarity of…
Moga, Tudor Voicu; Popescu, Alina; Sporea, Ioan; Danila, Mirela; David, Ciprian; Gui, Vasile; Iacob, Nicoleta; Miclaus, Gratian; Sirli, Roxana
2017-08-23
Contrast enhanced ultrasound (CEUS) improved the characterization of focal liver lesions (FLLs), but is an operatordependent method. The goal of this paper was to test a computer assisted diagnosis (CAD) prototype and to see its benefit in assisting a beginner in the evaluation of FLLs. Our cohort included 97 good quality CEUS videos[34% hepatocellular carcinomas (HCC), 12.3% hypervascular metastases (HiperM), 11.3% hypovascular metastases (HipoM), 24.7% hemangiomas (HMG), 17.5% focal nodular hyperplasia (FNH)] that were used to develop a CAD prototype based on an algorithm that tested a binary decision based classifier. Two young medical doctors (1 year CEUS experience), two experts and the CAD prototype, reevaluated 50 FLLs CEUS videos (diagnosis of benign vs. malignant) first blinded to clinical data, in order to evaluate the diagnostic gap beginner vs. expert. The CAD classifier managed a 75.2% overall (benign vs. malignant) correct classification rate. The overall classification rates for the evaluators, before and after clinical data were: first beginner-78%; 94%; second beginner-82%; 96%; first expert-94%; 100%; second expert-96%; 98%. For both beginners, the malignant vs. benign diagnosis significantly improved after knowing the clinical data (p=0.005; p=0,008). The expert was better than the beginner (p=0.04) and better than the CAD (p=0.001). CAD in addition to the beginner can reach the expert diagnosis. The most frequent lesions misdiagnosed at CEUS were FNH and HCC. The CAD prototype is a good comparing tool for a beginner operator that can be developed to assist the diagnosis. In order to increase the classification rate, the CAD system for FLL in CEUS must integrate the clinical data.
Verdugo, Fernando; Simonian, Krikor; Raffaelli, Luca; D'Addona, Antonio
2014-06-01
To evaluate and compare the volume of bone graft material that can be safely harvested from the mandibular symphysis and rami using a computer-aided design (CAD) software program. Preoperative computerized tomography scans from 40 patients undergoing bone augmentation procedures were analyzed. Symphysis and rami cross sections were mapped using a CAD software program (AutoCAD(®), Autodesk, Inc., San Rafael, CA, USA) to evaluate the bone volume that can be safely harvested. CAD calculations were contrasted to intrasurgical measurements in a subgroup of 20 individuals. CAD calculations yielded a safe harvestable osseous volume of 1.44 cm(3) ± 0.49 for the symphysis and 0.82 cm(3) ± 0.21 for each ramus (p < .0001, confidence interval [CI] 95%: 0.47-0.78). These measurements were significantly lower (p < .0001) than the bone volumes harvested intrasurgically for both symphysis and ramus, respectively (2.40 cm(3) ± 0.50 vs. 2.65 cm(3) ± 0.45). CAD calculations of harvestable symphysis and ramus bone translated into an average of 2.40 cm(3) ± 0.50 (range: 1.80-3.10 cm(3)) and 2.65 cm(3) ± 0.45 (range: 1.90-3.50) of particulate bone graft intrasurgically, respectively. Ramus cortical was significantly thicker than the symphysis cortical, 2.9 ± 0.4 mm versus 2.19 mm ± 0.4 mm (p < .0001, CI 95%: 0.45-1.03). The symphysis and rami are good harvesting sources to obtain dense corticocancellous bone. The significant volumetric CAD differences between the symphysis and ramus seem to balance out intrasurgically and may be due to the greater cortical bone volume at the ramus area. It is plausible to harvest an average of 7.70 cm(3) from the symphysis and rami alone. The use of a CAD software program can enhance surgical treatment planning prior to bone transplantation. © 2012 Wiley Periodicals, Inc.
Mehta, Puja K; Johnson, B Delia; Kenkre, Tanya S; Eteiba, Wafia; Sharaf, Barry; Pepine, Carl J; Reis, Steven E; Rogers, William J; Kelsey, Sheryl F; Thompson, Diane V; Bittner, Vera; Sopko, George; Shaw, Leslee J; Bairey Merz, C Noel
2017-08-21
Sudden cardiac death (SCD) is often the first presentation of ischemic heart disease; however, there is limited information on SCD among women with and without obstructive coronary artery disease (CAD). We evaluated SCD incidence in the WISE (Women's Ischemia Syndrome Evaluation) study. Overall, 904 women with suspected ischemic heart disease with preserved ejection fraction and core laboratory coronary angiography were followed for outcomes. In case of death, a death certificate and/or a physician or family narrative of the circumstances of death was obtained. A clinical events committee rated all deaths as cardiovascular or noncardiovascular and as SCD or non-SCD. In total, 96 women (11%) died over a median of 6 years (maximum: 8 years). Among 65 cardiovascular deaths, 42% were SCD. Mortality per 1000 person-hours increased linearly with CAD severity (no CAD: 5.8; minimal: 15.9; obstructive: 38.6; P <0.0001). However, the proportion of SCD was similar across CAD severity: 40%, 58%, and 38% for no, minimal, and obstructive CAD subgroups, respectively ( P value not significant). In addition to traditional risk factors (age, diabetes mellitus, smoking), a history of depression ( P =0.018) and longer corrected QT interval ( P =0.023) were independent SCD predictors in the entire cohort. Corrected QT interval was an independent predictor of SCD in women without obstructive CAD ( P =0.033). SCD contributes substantially to mortality in women with and without obstructive CAD. Corrected QT interval is the single independent SCD risk factor in women without obstructive CAD. In addition to management of traditional risk factors, these data indicate that further investigation should address mechanistic understanding and interventions targeting depression and corrected QT interval in women. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Construction and comparative evaluation of different activity detection methods in brain FDG-PET.
Buchholz, Hans-Georg; Wenzel, Fabian; Gartenschläger, Martin; Thiele, Frank; Young, Stewart; Reuss, Stefan; Schreckenberger, Mathias
2015-08-18
We constructed and evaluated reference brain FDG-PET databases for usage by three software programs (Computer-aided diagnosis for dementia (CAD4D), Statistical Parametric Mapping (SPM) and NEUROSTAT), which allow a user-independent detection of dementia-related hypometabolism in patients' brain FDG-PET. Thirty-seven healthy volunteers were scanned in order to construct brain FDG reference databases, which reflect the normal, age-dependent glucose consumption in human brain, using either software. Databases were compared to each other to assess the impact of different stereotactic normalization algorithms used by either software package. In addition, performance of the new reference databases in the detection of altered glucose consumption in the brains of patients was evaluated by calculating statistical maps of regional hypometabolism in FDG-PET of 20 patients with confirmed Alzheimer's dementia (AD) and of 10 non-AD patients. Extent (hypometabolic volume referred to as cluster size) and magnitude (peak z-score) of detected hypometabolism was statistically analyzed. Differences between the reference databases built by CAD4D, SPM or NEUROSTAT were observed. Due to the different normalization methods, altered spatial FDG patterns were found. When analyzing patient data with the reference databases created using CAD4D, SPM or NEUROSTAT, similar characteristic clusters of hypometabolism in the same brain regions were found in the AD group with either software. However, larger z-scores were observed with CAD4D and NEUROSTAT than those reported by SPM. Better concordance with CAD4D and NEUROSTAT was achieved using the spatially normalized images of SPM and an independent z-score calculation. The three software packages identified the peak z-scores in the same brain region in 11 of 20 AD cases, and there was concordance between CAD4D and SPM in 16 AD subjects. The clinical evaluation of brain FDG-PET of 20 AD patients with either CAD4D-, SPM- or NEUROSTAT-generated databases from an identical reference dataset showed similar patterns of hypometabolism in the brain regions known to be involved in AD. The extent of hypometabolism and peak z-score appeared to be influenced by the calculation method used in each software package rather than by different spatial normalization parameters.
Sailer, Irena; Benic, Goran I; Fehmer, Vincent; Hämmerle, Christoph H F; Mühlemann, Sven
2017-07-01
Clinical studies are needed to evaluate the entire digital and conventional workflows in prosthetic dentistry. The purpose of the second part of this clinical study was to compare the laboratory production time for tooth-supported single crowns made with 4 different digital workflows and 1 conventional workflow and to compare these crowns clinically. For each of 10 participants, a monolithic crown was fabricated in lithium disilicate-reinforced glass ceramic (IPS e.max CAD). The computer-aided design and computer-aided manufacturing (CAD-CAM) systems were Lava C.O.S. CAD software and centralized CAM (group L), Cares CAD software and centralized CAM (group iT), Cerec Connect CAD software and lab side CAM (group CiL), and Cerec Connect CAD software with centralized CAM (group CiD). The conventional fabrication (group K) included a wax pattern of the crown and heat pressing according to the lost-wax technique (IPS e.max Press). The time for the fabrication of the casts and the crowns was recorded. Subsequently, the crowns were clinically evaluated and the corresponding treatment times were recorded. The Paired Wilcoxon test with the Bonferroni correction was applied to detect differences among treatment groups (α=.05). The total mean (±standard deviation) active working time for the dental technician was 88 ±6 minutes in group L, 74 ±12 minutes in group iT, 74 ±5 minutes in group CiL, 92 ±8 minutes in group CiD, and 148 ±11 minutes in group K. The dental technician spent significantly more working time for the conventional workflow than for the digital workflows (P<.001). No statistically significant differences were found between group L and group CiD or between group iT and group CiL. No statistical differences in time for the clinical evaluation were found among groups, indicating similar outcomes (P>.05). Irrespective of the CAD-CAM system, the overall laboratory working time for a digital workflow was significantly shorter than for the conventional workflow, since the dental technician needed less active working time. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Tazawa, Yasushi; Mori, Nobuyoshi; Ogawa, Yoshiko; Ito, Osamu; Kohzuki, Masahiro
2016-06-01
Arterial stiffness is widely used in assessing arteriosclerosis in the background of increased cardiovascular events. Arteriosclerosis also causes reduction in exercise capacity, which is a most important prognostic factor in patients with cardiovascular disease; however, data on the association between arterial stiffness and exercise capacity are limited. Therefore, a simple and noninvasive measurement of arterial stiffness that reflects the central circulation and exercise capacity is needed. The arterial velocity pulse index (AVI) is a parameter of arterial stiffness measurable with the cuff oscillometric method; however, the clinical utility of this method is unclear. We aimed to evaluate the trend of AVI in patients with coronary artery disease (CAD), and the association between AVI and exercise capacity. A cross-sectional study of 116 patients with cardiac disease (34 CAD and 82 non-CAD patients) was performed. Non-CAD patients were those with any cardiac diseases who did not have proven CAD. The results showed that the AVI was significantly higher in CAD patients than non-CAD patients (P < 0.05, analysis of covariance). The AVI was inversely correlated with peakVO2 (r = -0.239, P < 0.05) and was a significant explanatory variable for peakVO2 in stepwise regression analysis (β = -14.62, t = -2.5, P < 0.05). These results indicate that the AVI is strongly associated with CAD and predictive of the exercise capacity in patients with cardiac diseases. We, therefore, propose that the cuff oscillometric method is clinically useful in evaluating arterial stiffness in patients with cardiac diseases, especially CAD.
A new approach of objective quality evaluation on JPEG2000 lossy-compressed lung cancer CT images
NASA Astrophysics Data System (ADS)
Cai, Weihua; Tan, Yongqiang; Zhang, Jianguo
2007-03-01
Image compression has been used to increase the communication efficiency and storage capacity. JPEG 2000 compression, based on the wavelet transformation, has its advantages comparing to other compression methods, such as ROI coding, error resilience, adaptive binary arithmetic coding and embedded bit-stream. However it is still difficult to find an objective method to evaluate the image quality of lossy-compressed medical images so far. In this paper, we present an approach to evaluate the image quality by using a computer aided diagnosis (CAD) system. We selected 77 cases of CT images, bearing benign and malignant lung nodules with confirmed pathology, from our clinical Picture Archiving and Communication System (PACS). We have developed a prototype of CAD system to classify these images into benign ones and malignant ones, the performance of which was evaluated by the receiver operator characteristics (ROC) curves. We first used JPEG 2000 to compress these cases of images with different compression ratio from lossless to lossy, and used the CAD system to classify the cases with different compressed ratio, then compared the ROC curves from the CAD classification results. Support vector machine (SVM) and neural networks (NN) were used to classify the malignancy of input nodules. In each approach, we found that the area under ROC (AUC) decreases with the increment of compression ratio with small fluctuations.
A new semiquantitative method for evaluation of metastasis progression.
Volarevic, A; Ljujic, B; Volarevic, V; Milovanovic, M; Kanjevac, T; Lukic, A; Arsenijevic, N
2012-01-01
Although recent technical advancements are directed toward developing novel assays and methods for detection of micro and macro metastasis, there are still no reports of reliable, simple to use imaging software that could be used for the detection and quantification of metastasis in tissue sections. We herein report a new semiquantitative method for evaluation of metastasis progression in a well established 4T1 orthotopic mouse model of breast cancer metastasis. The new semiquantitative method presented here was implemented by using the Autodesk AutoCAD 2012 program, a computer-aided design program used primarily for preparing technical drawings in 2 dimensions. By using the Autodesk AutoCAD 2012 software- aided graphical evaluation we managed to detect each metastatic lesion and we precisely calculated the average percentage of lung and liver tissue parenchyma with metastasis in 4T1 tumor-bearing mice. The data were highly specific and relevant to descriptive histological analysis, confirming reliability and accuracy of the AutoCAD 2012 software as new method for quantification of metastatic lesions. The new semiquantitative method using AutoCAD 2012 software provides a novel approach for the estimation of metastatic progression in histological tissue sections.
Yuce, Mert; Ulusoy, Mubin; Turk, Ayse Gozde
2017-12-22
To compare marginal and internal adaptations of porcelain laminate veneers fabricated with heat-pressed and CAD/CAM techniques, and to evaluate the clinical performances 2 years after cementation. Thirty heat-pressed and 31 CAD/CAM porcelain laminate veneers were fabricated for 12 patients. Silicone replicas of each veneer were obtained. Replicas were sectioned into 4 parts to measure adaptations of the veneers. A stereomicroscope was used to measure from 3 locations of replicas for marginal, and 9 locations for internal adaptations at 40x magnification. Clinical evaluations were done at baseline and 6, 12, 18, and 24 months after cementation according to the modified United States Public Health Service (USPHS) criteria. Independent samples t-test compared the adaptation values between heat-pressed and CAD/CAM groups. Paired t-test was used to evaluate marginal and internal adaptations of each group. Differences between the modified USPHS criteria ratings of heat-pressed and CAD/CAM groups were determined by the Mann-Whitney U test. Kaplan-Meier analysis was used to analyze the survival ratings of the veneers (p < 0.05). The mean marginal adaptation values of heat-pressed and CAD/CAM veneers were 295 and 314.98 μm, respectively, and there was no statistically significant difference (p = 0.541). Internal adaptation values of groups were not statistically different either (201.82 μm for heat pressed; 195.47 μm for CAD/CAM p = 0.734). When marginal and internal adaptation values were compared within groups, there were significant differences both for heat-pressed (p < 0.001) and CAD/CAM (p < 0.001). All veneers were rated 100% satisfactory during the 2-year period. Within the limitations of this study, fabrication method, whether CAD/CAM or heat-pressed, had no effect on the marginal and internal adaptation of porcelain laminate veneers. The results showed that both fabrication techniques performed well after 2 years of clinical performance. © 2017 by the American College of Prosthodontists.
Chen, Zhang-wei; Qian, Ju-ying; Jian, Ying; Ge, Lei; Liu, Xue-bo; Shu, Xian-hong; Ge, Junbo
2011-02-01
Aortic valve calcification (AVC) is common in the elderly and associated with increased cardiovascular mortality, while diabetes is one of the confirmed risk factors for coronary artery disease (CAD). In this study, we aimed to evaluate the prevalence and severity of CAD in type-2 diabetic patients with AVC. From June to December in 2007, a total of 325 consecutive patients with chest pain or chest distress were admitted for coronary angiography. The severity of CAD was evaluated by the Gensini score and the number of stenosed vessels. All patients underwent transthoracic echocardiography for detecting AVC. Compared with the patients without diabetes (n = 221), the type-2 diabetic patients (n = 104) had a similar prevalence of CAD (66.5% vs. 72.1%, P = 0.312). Further classified by the presence of AVC, patients with AVC had a higher prevalence of CAD, average Gensini score and the number of stenosed vessels, both in the group with and without diabetes. It was also demonstrated that the odds ratio (OR) of AVC for CAD in the diabetic patients was higher than in the non-diabetic ones (3.405 vs 2.515) after chi-square analysis (single-variable). However, at multivariable logistic regression analysis for CAD, the OR of AVC was 3.757 (P = 0.03) in diabetic group, while it did not achieve statistical significance in the non-diabetic group (OR = 2.130, P= 0.074). Type-2 diabetic patients with AVC had a higher prevalence of and more severe CAD.
Prakashini, K; Babu, Satish; Rajgopal, KV; Kokila, K Raja
2016-01-01
Aims and Objectives: To determine the overall performance of an existing CAD algorithm with thin-section computed tomography (CT) in the detection of pulmonary nodules and to evaluate detection sensitivity at a varying range of nodule density, size, and location. Materials and Methods: A cross-sectional prospective study was conducted on 20 patients with 322 suspected nodules who underwent diagnostic chest imaging using 64-row multi-detector CT. The examinations were evaluated on reconstructed images of 1.4 mm thickness and 0.7 mm interval. Detection of pulmonary nodules, initially by a radiologist of 2 years experience (RAD) and later by CAD lung nodule software was assessed. Then, CAD nodule candidates were accepted or rejected accordingly. Detected nodules were classified based on their size, density, and location. The performance of the RAD and CAD system was compared with the gold standard that is true nodules confirmed by consensus of senior RAD and CAD together. The overall sensitivity and false-positive (FP) rate of CAD software was calculated. Observations and Results: Of the 322 suspected nodules, 221 were classified as true nodules on the consensus of senior RAD and CAD together. Of the true nodules, the RAD detected 206 (93.2%) and 202 (91.4%) by the CAD. CAD and RAD together picked up more number of nodules than either CAD or RAD alone. Overall sensitivity for nodule detection with the CAD program was 91.4%, and FP detection per patient was 5.5%. The CAD showed comparatively higher sensitivity for nodules of size 4–10 mm (93.4%) and nodules in hilar (100%) and central (96.5%) location when compared to RAD's performance. Conclusion: CAD performance was high in detecting pulmonary nodules including the small size and low-density nodules. CAD even with relatively high FP rate, assists and improves RAD's performance as a second reader, especially for nodules located in the central and hilar region and for small nodules by saving RADs time. PMID:27578931
Arslan, Mustafa; Murat, Sema; Alp, Gulce; Zaimoglu, Ali
2018-01-01
The objectives of this in vitro study were to evaluate the flexural strength (FS), surface roughness (Ra), and hydrophobicity of polymethylmethacrylate (PMMA)-based computer-aided design/computer-aided manufacturing (CAD/CAM) polymers and to compare the properties of different CAD/CAM PMMA-based polymers with conventional heat-polymerized PMMA following thermal cycling. Twenty rectangular-shaped specimens (64 × 10 × 3.3 mm) were fabricated from three CAD/CAM PMMA-based polymers (M-PM Disc [M], AvaDent Puck Disc [A], and Pink CAD/CAM Disc Polident [P], and one conventional heat-polymerized PMMA (Promolux [C]), according to ISO 20795-1:2013 standards. The specimens were divided into two subgroups (n = 10), a control and a thermocycled group. The specimens in the thermocycled group were subjected to 5000 thermal cycling procedures (5 to 55°C; 30 s dwell times). The Ra value was measured using a profilometer. Contact angle (CA) was assessed using the sessile drop method to evaluate surface hydrophobicity. In addition, the FS of the specimens was tested in a universal testing machine at a crosshead speed of 1.0 mm/min. Surface texture of the materials was assessed using scanning electron microscope (SEM). The data were analyzed using two-way analysis of variance (ANOVA), followed by Tukey's HSD post-hoc test (α < 0.05). CAD/CAM PMMA-based polymers showed significantly higher FS than conventional heat-polymerized PMMA for each group (P < 0.001). CAD/CAM PMMA-based polymer [P] showed the highest FS, whereas conventional PMMA [C] showed the lowest FS before and after thermal cycling (P < 0.001). There were no significant differences among the Ra values of the tested denture base polymers in the control group (P > 0.05). In the thermocycled group, the lowest Ra value was observed for CAD/CAM PMMA-based polymer [M] (P < 0.001), whereas CAD/CAM PMMA-based polymers [A] and [P], and conventional PMMA [C] had similar Ra values (P > 0.05). Conventional PMMA [C] had a significantly lower CA and consequently lower hydrophobicity compared to the CAD/CAM polymers in the control group (P < 0.001). In the thermocycled group, CAD/CAM PMMA-based polymer [A] and conventional PMMA [C] had significantly higher CA, and consequently higher hydrophobicity when compared to CAD/CAM polymers [M] and [P] (P < 0.001). However, no significant differences were found among the other materials (P > 0.05). The FS and hydrophobicity of the CAD/CAM PMMA-based polymers were higher than the conventional heat-polymerized PMMA, whereas the CAD/CAM PMMA-based polymers had similar Ra values to the conventional PMMA. Thermocycling had a significant effect on FS and hydrophobicity except for the Ra of denture base materials.
Vojdani, Mahroo; Torabi, Kianoosh; Atashkar, Berivan; Heidari, Hossein; Torabi Ardakani, Mahshid
2016-01-01
Statement of the Problem: Marginal fitness is the most important criteria for evaluation of the clinical acceptability of a cast restoration. Marginal gap which is due to cement solubility and plaque retention is potentially detrimental to both tooth and periodontal tissues. Purpose: This in vitro study aimed to evaluate the marginal and internal fit of cobalt- chromium (Co-Cr) copings fabricated by two different CAD/CAM systems: (CAD/ milling and CAD/ Ceramill Sintron). Materials and Method: We prepared one machined standard stainless steel master model with following dimensions: 7 mm height, 5mm diameter, 90˚ shoulder marginal finish line with 1 mm width, 10˚ convergence angle and anti-rotational surface on the buccal aspect of the die. There were 10 copings produced from hard presintered Co-Cr blocks according to CAD/ Milling technique and ten copings from soft non- presintered Co-Cr blocks according to CAD/ Ceramill Sintron technique. Marginal and internal accuracies of copings were documented by the replica technique. Replicas were examined at ten reference points under a digital microscope (230X). The Student's t-test was used for statistical analysis. p< 0.001 was considered significant. Results: Statistically significant differences existed between the groups (p< 0.001). The CAD/milling group (hard copings) had a mean marginal discrepancy (MD) of 104 µm, axial discrepancy (AD) of 23 µm and occlusal discrepancy of 130 µm. For CAD/ Ceramill Sintron group, these values were 195 µm (MD), 46 µm (AD), and 232 µm (OD). Internal total discrepancy (ITD) for the CAD/milling group was 77 µm, whereas for the CAD/Ceramill Sintron group was 143 µm. Conclusion: Hard presintered Co-Cr copings had significantly higher marginal and internal accuracies compared to the soft non-presintered copings. PMID:27942545
Zimmermann, Moritz; Valcanaia, Andre; Neiva, Gisele; Mehl, Albert; Fasbinder, Dennis
2018-03-06
A wide variety of CAD/CAM materials are available for single-tooth restorations. CAD/CAM material characteristics are different and may influence CAM fabrication accuracy. There is no study investigating the influence of different CAD/CAM materials on the final fit of the restoration. The aim of this study was to evaluate the fit of endocrowns fabricated from different CAD/CAM materials using a new 3D evaluation method with an intraoral scanning system. The null hypothesis was that there are no significant differences for the fitting accuracy of different CAD/CAM materials. Preparation for an endocrown was performed on a maxillary right first molar on a typodont, and restorations were fabricated with a chairside CAD/CAM system (CEREC Omnicam, MCXL). Three groups using three different CAD/CAM materials were established (each n = 10): zirconia-reinforced lithium silicate ceramic (Celtra Duo; CD), leucite-reinforced silicate ceramic (Empress CAD; EM), resin nanoceramic (Lava Ultimate; LU). A 3D digital measurement technique (OraCheck, Cyfex AG) using an intraoral scanner (CEREC Omnicam) was used to measure the difference in fit between the three materials for a master endocrown preparation. The preparation scan and the endocrown fit scan were matched with special difference analysis software OraCheck. Three areas were selected for fitting accuracy measurements: margin (MA), axial (AX), occlusal (OC). Statistical analysis was performed using 80% percentile, one-way ANOVA, and post-hoc Scheffé test. Significance level was set to p = 0.05. Results varied from best 88.9 ± 7.7 μm for marginal fit of resin nanoceramic restorations (LU_MA) to worst 182.3 ± 24.0 μm for occlusal fit of zirconia-reinforced lithium silicate restorations (CD_OC). Statistically significant differences were found both within and among the test groups. Group CD performed statistically significantly different from group LU for marginal fit (MA) and axial fit (AX) (p < 0.05). For occlusal fit (OC), no statistically significant differences were found within all three test groups (p > 0.05). Deviation pattern for differences was visually analyzed with a color-coded scheme for each restoration. Statistically significant differences were found for different CAD/CAM materials if the CAM procedure was identical. Within the limitations of this study, the choice of CAD/CAM material may influence the fitting accuracy of CAD/CAM-fabricated restorations. © 2018 by the American College of Prosthodontists.
Bidra, Avinash S; Farrell, Kimberly; Burnham, David; Dhingra, Ajay; Taylor, Thomas D; Kuo, Chia-Ling
2016-05-01
Presently, no studies have evaluated clinical outcomes or patient-centered outcomes for complete dentures fabricated with computer-aided design and computer aided manufacturing (CAD/CAM) technology. The purpose of this prospective cohort pilot study was to evaluate the clinical and patient-centered outcomes for CAD/CAM monolithic dentures fabricated in 2 visits. Twenty participants with an existing set of maxillary complete dentures opposing either mandibular complete dentures or implant-retained overdentures that required replacement were recruited in this study. A 2-visit duplicate denture protocol was used to fabricate 40 arches of monolithic dentures with CAD/CAM technology. A 100-mm visual analog scale (VAS) instrument was then used to record 12 outcomes at baseline and at 1-year follow-up. Predetermined values were assigned to grade the VAS rating of each outcome as favorable (70.1-100) and unfavorable (≤70). Favorable ratings were sub-divided as excellent (90.1-100), good (80.1-90), and fair (70.1-80). The clinical outcomes were evaluated independently by 2 experienced prosthodontists at baseline and at 1-year follow-up. Patients evaluated the corresponding patient-centered outcomes during the same time intervals. Additional descriptive variables were also recorded. Each clinical and patient-centered outcome was summarized by medians and ranges. Differences in all ratings recorded at baseline and at 1 year were tested by 1-sided sign test (α=.05). Of 20 participants, 3 were lost to follow-up, and 3 were unsatisfied with the digital dentures and withdrew from the study. These 3 participants were considered treatment failures. Of the 14 remaining participants, 9 had implant-retained mandibular overdentures, and 5 had conventional mandibular complete dentures. For clinical outcomes, the 12 studied outcomes were favorably evaluated by the 2 prosthodontist judges at the 1-year follow-up. Evaluations showed minimal differences between baseline and 1 year. An average of 5 emails (0-11) per patient were sent to the laboratory technicians to communicate the improvisation the CAD design of the dentures. An average of 3.3 denture adjustments were needed after insertion (0-10) during the 1-year period. For patient-centered outcomes, median ratings of all 14 participants indicated each of the 12 studied outcomes was favorable at the 1-year recall. Statistically significant improvements in patient ratings from baseline to 1 year were observed for the absence of denture sore spots and treatment time to make the dentures (P<.05). Minor complications related to loss of retention, excessive wear of teeth and the need for additional visits were observed in 5 participants. No other adverse clinical outcomes related to the CAD/CAM dentures were noted in the 14 evaluated participants, and all dentures were intact and in good condition at the 1-year follow-up. Clinical and patient-centered outcomes for CAD/CAM monolithic dentures fabricated using a 2-visit protocol were evaluated favorably at a 1-year follow-up. However, the proportion of excellent and good ratings for overall satisfaction and assessment was higher for patients than clinicians. A considerable amount of the clinician's time and effort was devoted to aiding in the digital process for the fabrication of CAD/CAM dentures. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Moradi, Maryam; Varasteh, Elham
2016-01-01
Coronary artery calcification (CAC) is a specific indicator of and a sensitive marker for the atherosclerotic disease process. However, calcium scoring may miss noncalcified plaques with clinical importance. The present study aimed to identify the presence and extent of coronary plaques in computed tomography coronary angiography (CTCA) in patients with a zero CAC score and the secondary endpoint was to evaluate the association between coronary risk factors and the presence of noncalcified plaques. In a retrospective descriptive-analytic study, a total of 2000 consecutive patients who undergone CTCA between September 2012 and September 2014 at Alzahra Hospital in Isfahan, Iran were analyzed. Three hundred and eighty-five patients with a zero calcium score were included in the study. The demographic information and coronary artery disease (CAD), risk factors including diabetes mellitus (DM), hypertension, hyperlipidemia, smoking, and family history of CAD, were obtained from the questionnaire. Furthermore, the presence of plaques and extent of stenosis were evaluated in patients with zero CAC score. Of the 385 patients with a zero calcium score, 16 (4.2%) had atherosclerotic plaques. Among them, 6 (1.6%) had significant (>50%) coronary stenosis, and 10 (2.6%) had no significant (<50%) coronary stenosis. Hyperlipidemia, DM, and smoking were significantly associated with obstructive CAD. Furthermore, in patients with zero calcium score, DM, hyperlipidemia, and smoking had odds ratios of 5.9, 14, and 32.5 for the development of coronary artery plaques, respectively. Although, CAC scoring is a noninvasive and valuable method to evaluate CAD; but zero CAC score does not absolutely exclude the CAD, especially in the presence of risk factors such as diabetes, hyperlipidemia, and smoking.
On the Use of CAD-Native Predicates and Geometry in Surface Meshing
NASA Technical Reports Server (NTRS)
Aftosmis, M. J.
1999-01-01
Several paradigms for accessing computer-aided design (CAD) geometry during surface meshing for computational fluid dynamics are discussed. File translation, inconsistent geometry engines, and nonnative point construction are all identified as sources of nonrobustness. The paper argues in favor of accessing CAD parts and assemblies in their native format, without translation, and for the use of CAD-native predicates and constructors in surface mesh generation. The discussion also emphasizes the importance of examining the computational requirements for exact evaluation of triangulation predicates during surface meshing.
Baskaran, Lohendran; Danad, Ibrahim; Gransar, Heidi; Ó Hartaigh, Bríain; Schulman-Marcus, Joshua; Lin, Fay Y; Peña, Jessica M; Hunter, Amanda; Newby, David E; Adamson, Philip D; Min, James K
2018-04-13
This study sought to compare the performance of history-based risk scores in predicting obstructive coronary artery disease (CAD) among patients with stable chest pain from the SCOT-HEART study. Risk scores for estimating pre-test probability of CAD are derived from referral-based populations with a high prevalence of disease. The generalizability of these scores to lower prevalence populations in the initial patient encounter for chest pain is uncertain. We compared 3 scores among patients with suspected CAD in the coronary computed tomographic angiography (CTA) randomized arm of the SCOT-HEART study for the outcome of obstructive CAD by coronary CTA: the updated Diamond-Forrester score (UDF), CAD Consortium clinical score (CAD2), and CONFIRM risk score (CRS). We tested calibration with goodness-of-fit, discrimination with area under the receiver-operating curve (AUC), and reclassification with net reclassification improvement (NRI) to identify low-risk patients. In 1,738 patients (58 ± 10 years and 44.0% women), overall calibration was best for UDF, with underestimation by CRS and CAD2. Discrimination by AUC was highest for CAD2 at 0.79 (95% confidence interval [CI]: 0.77 to 0.81) than for UDF (0.77 [95% CI: 0.74 to 0.79]) or CRS (0.75 [95% CI: 0.73 to 0.77]) (p < 0.001 for both comparisons). Reclassification of low-risk patients at the 10% probability threshold was best for CAD2 (NRI 0.31, 95% CI: 0.27 to 0.35) followed by CRS (NRI 0.21, 95% CI: 0.17 to 0.25) compared with UDF (p < 0.001 for all comparisons), with a consistent trend at the 15% threshold. In this multicenter clinic-based cohort of patients with suspected CAD and uniform CAD evaluation by coronary CTA, CAD2 provided the best discrimination and classification, despite overestimation of obstructive CAD as evaluated by coronary CTA. CRS exhibited intermediate performance followed by UDF for discrimination and reclassification. Copyright © 2018. Published by Elsevier Inc.
NASA Astrophysics Data System (ADS)
Adnan, F. A.; Romlay, F. R. M.; Shafiq, M.
2018-04-01
Owing to the advent of the industrial revolution 4.0, the need for further evaluating processes applied in the additive manufacturing application particularly the computational process for slicing is non-trivial. This paper evaluates a real-time slicing algorithm for slicing an STL formatted computer-aided design (CAD). A line-plane intersection equation was applied to perform the slicing procedure at any given height. The application of this algorithm has found to provide a better computational time regardless the number of facet in the STL model. The performance of this algorithm is evaluated by comparing the results of the computational time for different geometry.
Blackmon, Kevin N; Florin, Charles; Bogoni, Luca; McCain, Joshua W; Koonce, James D; Lee, Heon; Bastarrika, Gorka; Thilo, Christian; Costello, Philip; Salganicoff, Marcos; Joseph Schoepf, U
2011-06-01
To evaluate the effect of a computer-aided detection (CAD) algorithm on the performance of novice readers for detection of pulmonary embolism (PE) at CT pulmonary angiography (CTPA). We included CTPA examinations of 79 patients (50 female, 52 ± 18 years). Studies were evaluated by two independent inexperienced readers who marked all vessels containing PE. After 3 months all studies were reevaluated by the same two readers, this time aided by CAD prototype. A consensus read by three expert radiologists served as the reference standard. Statistical analysis used χ(2) and McNemar testing. Expert consensus revealed 119 PEs in 32 studies. For PE detection, the sensitivity of CAD alone was 78%. Inexperienced readers' initial interpretations had an average per-PE sensitivity of 50%, which improved to 71% (p < 0.001) with CAD as a second reader. False positives increased from 0.18 to 0.25 per study (p = 0.03). Per-study, the readers initially detected 27/32 positive studies (84%); with CAD this number increased to 29.5 studies (92%; p = 0.125). Our results suggest that CAD significantly improves the sensitivity of PE detection for inexperienced readers with a small but appreciable increase in the rate of false positives.
Computerized Analysis of Digital Photographs for Evaluation of Tooth Movement.
Toodehzaeim, Mohammad Hossein; Karandish, Maryam; Karandish, Mohammad Nabi
2015-03-01
Various methods have been introduced for evaluation of tooth movement in orthodontics. The challenge is to adopt the most accurate and most beneficial method for patients. This study was designed to introduce analysis of digital photographs with AutoCAD software as a method to evaluate tooth movement and assess the reliability of this method. Eighteen patients were evaluated in this study. Three intraoral digital images from the buccal view were captured from each patient in half an hour interval. All the photos were sent to AutoCAD software 2011, calibrated and the distance between canine and molar hooks were measured. The data was analyzed using intraclass correlation coefficient. Photographs were found to have high reliability coefficient (P > 0.05). The introduced method is an accurate, efficient and reliable method for evaluation of tooth movement.
Bertoldi, Eduardo G; Stella, Steffen F; Rohde, Luis Eduardo P; Polanczyk, Carisi A
2017-05-04
The aim of this research is to evaluate the relative cost-effectiveness of functional and anatomical strategies for diagnosing stable coronary artery disease (CAD), using exercise (Ex)-ECG, stress echocardiogram (ECHO), single-photon emission CT (SPECT), coronary CT angiography (CTA) or stress cardiacmagnetic resonance (C-MRI). Decision-analytical model, comparing strategies of sequential tests for evaluating patients with possible stable angina in low, intermediate and high pretest probability of CAD, from the perspective of a developing nation's public healthcare system. Hypothetical cohort of patients with pretest probability of CAD between 20% and 70%. The primary outcome is cost per correct diagnosis of CAD. Proportion of false-positive or false-negative tests and number of unnecessary tests performed were also evaluated. Strategies using Ex-ECG as initial test were the least costly alternatives but generated more frequent false-positive initial tests and false-negative final diagnosis. Strategies based on CTA or ECHO as initial test were the most attractive and resulted in similar cost-effectiveness ratios (I$ 286 and I$ 305 per correct diagnosis, respectively). A strategy based on C-MRI was highly effective for diagnosing stable CAD, but its high cost resulted in unfavourable incremental cost-effectiveness (ICER) in moderate-risk and high-risk scenarios. Non-invasive strategies based on SPECT have been dominated. An anatomical diagnostic strategy based on CTA is a cost-effective option for CAD diagnosis. Functional strategies performed equally well when based on ECHO. C-MRI yielded acceptable ICER only at low pretest probability, and SPECT was not cost-effective in our analysis. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Shufelt, Chrisandra; Johnson, B. Delia; Berga, Sarah L.; Braunstein, Glenn D.; Reis, Steven E.; Bittner, Vera; Yang, YuChing; Pepine, Carl J.; Sharaf, Barry L.; Sopko, George; Kelsey, Sheryl F.; Merz, C. Noel Bairey
2011-01-01
Objective To assess the relationship of timing of hormone therapy (HT) use with angiographic coronary artery disease (CAD) and cardiovascular disease (CVD) events in women with natural versus surgical menopause. Methods We studied 654 postmenopausal women undergoing coronary angiography for evaluation of suspected ischemia. Timing and type of menopause, HT use, and quantitative angiographic evaluations were obtained at baseline, and the women were followed for a median of 6 years for CVD events. Results Ever users of HT had a significantly lower prevalence of obstructive CAD compared to never users (age-adjusted OR=0.41 [0.28, 0.60]). Naturally menopausal women initiating HT at age <55 years had lower CAD severity compared to never users (age-adjusted beta [SE] = −6.23 [1.50], p<0.0001) while those initiating HT age ≥55 years did not differ statistically from never users (−3.34 [2.13], p=0.12). HT use remained a significant predictor of obstructive CAD when adjusting for a “healthy user” model OR 0.44 [0.30, 0.73] (p=0.002). An association between HT and fewer CVD events was observed only in the natural menopause group (HR [95%CI] = 0.60[0.41, 0.88], p=0.009) but became non-significant when adjusting for presence or severity of obstructive CAD. Conclusions Using quantitative measurements of timing and type of menopause and HT use, earlier initiation of HT was associated with less angiographic CAD in women with natural but not surgical menopause. Our data suggest that the effect of HT use on reduced cardiovascular event rates is mediated by the presence or absence of angiographic obstructive atherosclerosis. PMID:21532511
Shufelt, Chrisandra L; Johnson, B Delia; Berga, Sarah L; Braunstein, Glenn D; Reis, Steven E; Bittner, Vera; Yang, YuChing; Pepine, Carl J; Sharaf, Barry L; Sopko, George; Kelsey, Sheryl F; Merz, C Noel Bairey
2011-09-01
The aim of this study was to assess the relationship of the timing of hormone therapy (HT) use with angiographic coronary artery disease (CAD) and cardiovascular disease (CVD) events in women with natural versus surgical menopause. We studied 654 postmenopausal women undergoing coronary angiography for the evaluation of suspected ischemia. Timing and type of menopause, HT use, and quantitative angiographic evaluations were obtained at baseline, and the women were followed for a median of 6 years for CVD events. Ever users of HT had a significantly lower prevalence of obstructive CAD compared with never users (age-adjusted odds ratio, 0.41 [0.28-0.60]). Women with natural menopause initiating HT before age 55 years had lower CAD severity compared with never users (age-adjusted β [SE] = -6.23 [1.50], P < 0.0001), whereas those initiating HT at age 55 years or more did not differ statistically from never users (-3.34 [2.13], P = 0.12). HT use remained a significant predictor of obstructive CAD when adjusted for a "healthy user" model (odds ratio, 0.44 [0.30-0.73]; P = 0.002). An association between HT and fewer CVD events was observed only in the natural menopause group (hazard ratio [95% CI], 0.60 [0.41-0.88]; P = 0.009) but became nonsignificant when adjusted for the presence or severity of obstructive CAD. Using the quantitative measurements of the timing and type of menopause and HT use, earlier initiation of HT was associated with less angiographic CAD in women with natural but not surgical menopause. Our data suggest that the effect of HT use on reduced cardiovascular event rates is mediated by the presence or absence of angiographic obstructive atherosclerosis.
NASA Astrophysics Data System (ADS)
Le, Anh H.; Park, Young W.; Ma, Kevin; Jacobs, Colin; Liu, Brent J.
2010-03-01
Multiple Sclerosis (MS) is a progressive neurological disease affecting myelin pathways in the brain. Multiple lesions in the white matter can cause paralysis and severe motor disabilities of the affected patient. To solve the issue of inconsistency and user-dependency in manual lesion measurement of MRI, we have proposed a 3-D automated lesion quantification algorithm to enable objective and efficient lesion volume tracking. The computer-aided detection (CAD) of MS, written in MATLAB, utilizes K-Nearest Neighbors (KNN) method to compute the probability of lesions on a per-voxel basis. Despite the highly optimized algorithm of imaging processing that is used in CAD development, MS CAD integration and evaluation in clinical workflow is technically challenging due to the requirement of high computation rates and memory bandwidth in the recursive nature of the algorithm. In this paper, we present the development and evaluation of using a computing engine in the graphical processing unit (GPU) with MATLAB for segmentation of MS lesions. The paper investigates the utilization of a high-end GPU for parallel computing of KNN in the MATLAB environment to improve algorithm performance. The integration is accomplished using NVIDIA's CUDA developmental toolkit for MATLAB. The results of this study will validate the practicality and effectiveness of the prototype MS CAD in a clinical setting. The GPU method may allow MS CAD to rapidly integrate in an electronic patient record or any disease-centric health care system.
Horne, Benjamin D.; May, Heidi T.; Anderson, Jeffrey L.; Kfoury, Abdallah G.; Bailey, Beau M.; McClure, Brian S.; Renlund, Dale G.; Lappé, Donald L.; Carlquist, John F.; Fisher, Patrick W.; Pearson, Robert R.; Bair, Tami L.; Adams, Ted D.; Muhlestein, Joseph B.
2008-01-01
Coronary artery disease (CAD) is common and multi-factorial. Members of the Church of Jesus Christ of Latter-day Saints (LDS, or Mormons) in Utah may have lower cardiac mortality than other Utahns and the US population. While the LDS proscription of smoking likely contributes to lower cardiac risk, it is unknown whether other shared behaviors also contribute. This study evaluated potential CAD-associated effects of fasting. Patients (N1=4,629) enrolled in the Intermountain Heart Collaborative Study registry (1994-2002) were evaluated for association of religious preference with CAD diagnosis (≥70% coronary stenosis on angiography) or no CAD (normal coronaries, <10% stenosis). Consequently, another set of patients (N2=448) were surveyed (2004-2006) for association of behavioral factors with CAD, with the primary variable being routine fasting (i.e., abstinence from food and drink). Secondary survey measures included proscription of alcohol, tea, and coffee, social support, and religious worship patterns. In population 1 (initial), 61% of LDS and 66% of all others had CAD (adjusted [including for smoking]: odds ratio [OR]=0.81; p=0.009). In population 2 (survey), fasting was associated with lower risk of CAD (64% vs. 76% CAD; OR=0.55, CI=0.35, 0.87; p=0.010) and this remained after adjustment for traditional risk factors (OR=0.46, CI=0.27, 0.81; p=0.007). Fasting was also associated with lower diabetes prevalence (p=0.048). In regression models entering other secondary behavioral measures, fasting remained significant with similar effect size. In conclusion, not only proscription of tobacco, but also routine periodic fasting was associated with lower risk of CAD. PMID:18805103
Bittencourt, Marcio S; Hulten, Edward A; Ghoshhajra, Brian; Abbara, Suhny; Murthy, Venkatesh L; Divakaran, Sanjay; Nasir, Khurram; Gowdak, Luis Henrique W; Riella, Leonardo V; Chiumiento, Marco; Hoffmann, Udo; Di Carli, Marcelo F; Blankstein, Ron
2015-07-01
It is unknown whether mild chronic kidney disease (CKD) is associated with adverse cardiovascular (CV) prognosis after accounting for coronary artery disease (CAD). Here we evaluated the interplay between CKD and CAD in predicting CV death or myocardial infarction (MI) and all-cause death. We included 1541 consecutive patients in the Partners registry (mean age 55 years, 43% female) over 18 years old with no known prior CAD who underwent coronary computed tomography angiography (CCTA). The results of CCTA were categorized as normal, nonobstructive (under half), or obstructive (half and over). Overall, 653 of the patients had no CAD, 583 had nonobstructive CAD, and 305 had obstructive CAD, while 1299 had eGFR over 60 ml/min per 1.73 m(2) and 242 had an eGFR under this value. The presence and severity of CAD was significantly associated with an increased rate of CV death or MI and all-cause death, even after adjustment for age, gender, symptoms, and risk factors. Similarly, reduced eGFR was significantly associated with CV death or MI and all-cause death after similar adjustment. The addition of reduced GFR to a model which included both clinical variables and CCTA findings resulted in significant improvement in the prediction of CV death or MI and all-cause death. Thus, among individuals referred for CCTA to evaluate CAD, renal dysfunction is associated with an increased rate of CV events, mainly driven by an increase in the rate of noncoronary CV events. In this group of patients, both eGFR and the presence and severity of CAD together improve the prediction of future CV events and death.
Sporns, Peter B; Niederstadt, Thomas; Heindel, Walter; Raschke, Michael J; Hartensuer, René; Dittrich, Ralf; Hanning, Uta
2018-01-26
Cervical artery dissection (CAD) is an important etiology of ischemic stroke and early recognition is vital to protect patients from the major complication of cerebral embolization by administration of anticoagulants. The etiology of arterial dissections differ and can be either spontaneous or traumatic. Even though the historical gold standard is still catheter angiography, recent studies suggest a good performance of computed tomography angiography (CTA) for detection of CAD. We conducted this research to evaluate the variety and frequency of possible imaging signs of spontaneous and traumatic CAD and to guide neuroradiologists' decision making. Retrospective review of the database of our multiple injured patients admitted to the Department of Trauma, Hand, and Reconstructive Surgery of the University Hospital Münster in Germany (a level 1 trauma center) for patients with traumatic CAD (tCAD) and of our stroke database (2008-2015) for patients with spontaneous CAD (sCAD) and CT/CTA on initial clinical work-up. All images were evaluated concerning specific and sensitive radiological features for dissection by two experienced neuroradiologists. Imaging features were compared between the two etiologies. This study included 145 patients (99 male, 46 female; 45 ± 18.8 years of age), consisting of 126 dissected arteries with a traumatic and 43 with spontaneous etiology. Intimal flaps were more frequently observed after traumatic etiology (58.1% tCADs, 6.9% sCADs; p < 0.001); additionally, multivessel dissections were much more frequent in trauma patients (3 sCADs, 21 tCADs) and only less than half (42%) of the patients with traumatic dissections showed cervical spine fractures. Neuroradiologists should be aware that intimal flaps and multivessel dissections are more common after a traumatic etiology. In addition, it seems important to conduct a CTA in a trauma setting, even if no cervical spine fracture is detected.
Schaap, Jeroen; Kauling, Robert M; Boekholdt, S Matthijs; Post, Martijn C; Van der Heyden, Jan A; de Kroon, Thom L; van Es, H Wouter; Rensing, Benno J W M; Verzijlbergen, J Fred
2013-03-01
Coronary calcium scoring (CCS) adds to the diagnostic performance of myocardial perfusion single-photon emission computed tomography (SPECT) to assess the presence of significant coronary artery disease (CAD). Patients with a high pre-test likelihood are expected to have a high CCS which potentially could enhance the diagnostic performance of myocardial perfusion SPECT in this specific patient group. We evaluated the added value of CCS to SPECT in the diagnosis of significant CAD in patients with an intermediate to high pre-test likelihood. In total, 129 patients (mean age 62.7 ± 9.7 years, 65 % male) with stable anginal complaints and intermediate to high pre-test likelihood of CAD (median 87 %, range 22-95) were prospectively included in this study. All patients received SPECT and CCS imaging preceding invasive coronary angiography (CA). Fractional flow reserve (FFR) measurements were acquired from patients with angiographically estimated 50-95 % obstructive CAD. For SPECT a SSS > 3 was defined significant CAD. For CCS the optimal cut-off value for significant CAD was determined by ROC curve analysis. The reference standard for significant CAD was a FFR of <0.80 acquired by CA. Significant CAD was demonstrated in 64 patients (49.6 %). Optimal CCS cut-off value for significant CAD was >182.5. ROC curve analysis for prediction of the presence of significant CAD for SPECT, CCS and the combination of CCS and SPECT resulted in an area under the curve (AUC) of 0.88 (95 % CI 81-94), 0.75 (95 % CI 66-83 %) and 0.92 (95 % CI 87-97 %) respectively. The difference of the AUC between SPECT and the combination of CCS and SPECT was 0.05 (P = 0.12). The addition of CCS did not significantly improve the diagnostic performance of SPECT in the evaluation of patients with a predominantly high pre-test likelihood of CAD.
Chow, Benjamin J W; Small, Gary; Yam, Yeung; Chen, Li; McPherson, Ruth; Achenbach, Stephan; Al-Mallah, Mouaz; Berman, Daniel S; Budoff, Matthew J; Cademartiri, Filippo; Callister, Tracy Q; Chang, Hyuk-Jae; Cheng, Victor Y; Chinnaiyan, Kavitha; Cury, Ricardo; Delago, Augustin; Dunning, Allison; Feuchtner, Gundrun; Hadamitzky, Martin; Hausleiter, Jörg; Karlsberg, Ronald P; Kaufmann, Philipp A; Kim, Yong-Jin; Leipsic, Jonathon; LaBounty, Troy; Lin, Fay; Maffei, Erica; Raff, Gilbert L; Shaw, Leslee J; Villines, Todd C; Min, James K
2015-04-01
We sought to examine the risk of mortality associated with nonobstructive coronary artery disease (CAD) and to determine the impact of baseline statin and aspirin use on mortality. Coronary computed tomographic angiography permits direct visualization of nonobstructive CAD. To date, the prognostic implications of nonobstructive CAD and the potential benefit of directing therapy based on nonobstructive CAD have not been carefully examined. A total of 27 125 consecutive patients who underwent computed tomographic angiography (12 enrolling centers and 6 countries) were prospectively entered into the COronary CT Angiography EvaluatioN For Clinical Outcomes: An InteRnational Multicenter (CONFIRM) registry. Patients, without history of previous CAD or obstructive CAD, for whom baseline statin and aspirin use was available were analyzed. Each coronary segment was classified as normal or nonobstructive CAD (1%-49% stenosis). Patients were followed up for a median of 27.2 months for all-cause mortality. The study comprised 10 418 patients (5712 normal and 4706 with nonobstructive CAD). In multivariable analyses, patients with nonobstructive CAD had a 6% (95% confidence interval, 1%-12%) higher risk of mortality for each additional segment with nonobstructive plaque (P=0.021). Baseline statin use was associated with a reduced risk of mortality (hazard ratio, 0.44; 95% confidence interval, 0.28-0.68; P=0.0003), a benefit that was present for individuals with nonobstructive CAD (hazard ratio, 0.32; 95% confidence interval, 0.19-0.55; P<0.001) but not for those without plaque (hazard ratio, 0.66; 95% confidence interval, 0.30-1.43; P=0.287). When stratified by National Cholesterol Education Program/Adult Treatment Program III, no mortality benefit was observed in individuals without plaque. Aspirin use was not associated with mortality benefit, irrespective of the status of plaque. The presence and extent of nonobstructive CAD predicted mortality. Baseline statin therapy was associated with a significant reduction in mortality for individuals with nonobstructive CAD but not for individuals without CAD. URL: http://clinicaltrials.gov/. Unique identifier NCT01443637. © 2015 American Heart Association, Inc.
The USEPA's National Homeland Security Research Center (NHSRC)Technology Testing and Evaluation Program (TTEP) is carrying out performance tests on homeland security technologies. Under TTEP, Battelle recently evaluated the performance of the Science Applications International Co...
CAD/CAM glass ceramics for single-tooth implant crowns: a finite element analysis.
Akça, Kvanç; Cavusoglu, Yeliz; Sagirkaya, Elcin; Aybar, Buket; Cehreli, Murat Cavit
2013-12-01
To evaluate the load distribution of CAD/CAM mono-ceramic crowns supported with single-tooth implants in functional area. A 3-dimensional numerical model of a soft tissue-level implant was constructed with cement-retained abutment to support glass ceramic machinable crown. Implant-abutment complex and the retained crown were embedded in a Ø 1.5 × 1.5 cm geometric matrix for evaluation of mechanical behavior of mono-ceramic CAD/CAM aluminosilicate and leucite glass crown materials. Laterally positioned axial load of 300 N was applied on the crowns. Resulting principal stresses in the mono-ceramic crowns were evaluated in relation to different glass ceramic materials. The highest compressive stresses were observed at the cervical region of the buccal aspect of the crowns and were 89.98 and 89.99 MPa, for aluminosilicate and leucite glass ceramics, respectively. The highest tensile stresses were observed at the collar of the lingual part of the crowns and were 24.54 and 25.39 MPa, respectively. Stresses induced upon 300 N static loading of CAD/CAM aluminosalicate and leucite glass ceramics are below the compressive strength of the materials. Impact loads may actuate the progress to end failure of mono-ceramic crowns supported by metallic implant abutments.
Accuracy evaluation of dental models manufactured by CAD/CAM milling method and 3D printing method.
Jeong, Yoo-Geum; Lee, Wan-Sun; Lee, Kyu-Bok
2018-06-01
To evaluate the accuracy of a model made using the computer-aided design/computer-aided manufacture (CAD/CAM) milling method and 3D printing method and to confirm its applicability as a work model for dental prosthesis production. First, a natural tooth model (ANA-4, Frasaco, Germany) was scanned using an oral scanner. The obtained scan data were then used as a CAD reference model (CRM), to produce a total of 10 models each, either using the milling method or the 3D printing method. The 20 models were then scanned using a desktop scanner and the CAD test model was formed. The accuracy of the two groups was compared using dedicated software to calculate the root mean square (RMS) value after superimposing CRM and CAD test model (CTM). The RMS value (152±52 µm) of the model manufactured by the milling method was significantly higher than the RMS value (52±9 µm) of the model produced by the 3D printing method. The accuracy of the 3D printing method is superior to that of the milling method, but at present, both methods are limited in their application as a work model for prosthesis manufacture.
The effect of various veneering techniques on the marginal fit of zirconia copings.
Torabi, Kianoosh; Vojdani, Mahroo; Giti, Rashin; Taghva, Masumeh; Pardis, Soheil
2015-06-01
This study aimed to evaluate the fit of zirconia ceramics before and after veneering, using 3 different veneering processes (layering, press-over, and CAD-on techniques). Thirty standardized zirconia CAD/CAM frameworks were constructed and divided into three groups of 10 each. The first group was veneered using the traditional layering technique. Press-over and CAD-on techniques were used to veneer second and third groups. The marginal gap of specimens was measured before and after veneering process at 18 sites on the master die using a digital microscope. Paired t-test was used to evaluate mean marginal gap changes. One-way ANOVA and post hoc tests were also employed for comparison among 3 groups (α=.05). Marginal gap of 3 groups was increased after porcelain veneering. The mean marginal gap values after veneering in the layering group (63.06 µm) was higher than press-over (50.64 µm) and CAD-on (51.50 µm) veneered groups (P<.001). Three veneering methods altered the marginal fit of zirconia copings. Conventional layering technique increased the marginal gap of zirconia framework more than pressing and CAD-on techniques. All ceramic crowns made through three different veneering methods revealed clinically acceptable marginal fit.
Path length entropy analysis of diastolic heart sounds.
Griffel, Benjamin; Zia, Mohammad K; Fridman, Vladamir; Saponieri, Cesare; Semmlow, John L
2013-09-01
Early detection of coronary artery disease (CAD) using the acoustic approach, a noninvasive and cost-effective method, would greatly improve the outcome of CAD patients. To detect CAD, we analyze diastolic sounds for possible CAD murmurs. We observed diastolic sounds to exhibit 1/f structure and developed a new method, path length entropy (PLE) and a scaled version (SPLE), to characterize this structure to improve CAD detection. We compare SPLE results to Hurst exponent, Sample entropy and Multiscale entropy for distinguishing between normal and CAD patients. SPLE achieved a sensitivity-specificity of 80%-81%, the best of the tested methods. However, PLE and SPLE are not sufficient to prove nonlinearity, and evaluation using surrogate data suggests that our cardiovascular sound recordings do not contain significant nonlinear properties. Copyright © 2013 Elsevier Ltd. All rights reserved.
Path Length Entropy Analysis of Diastolic Heart Sounds
Griffel, B.; Zia, M. K.; Fridman, V.; Saponieri, C.; Semmlow, J. L.
2013-01-01
Early detection of coronary artery disease (CAD) using the acoustic approach, a noninvasive and cost-effective method, would greatly improve the outcome of CAD patients. To detect CAD, we analyze diastolic sounds for possible CAD murmurs. We observed diastolic sounds to exhibit 1/f structure and developed a new method, path length entropy (PLE) and a scaled version (SPLE), to characterize this structure to improve CAD detection. We compare SPLE results to Hurst exponent, Sample entropy and Multi-scale entropy for distinguishing between normal and CAD patients. SPLE achieved a sensitivity-specificity of 80%–81%, the best of the tested methods. However, PLE and SPLE are not sufficient to prove nonlinearity, and evaluation using surrogate data suggests that our cardiovascular sound recordings do not contain significant nonlinear properties. PMID:23930808
Bonding Effectiveness of Luting Composites to Different CAD/CAM Materials.
Peumans, Marleen; Valjakova, Emilija Bajraktarova; De Munck, Jan; Mishevska, Cece Bajraktarova; Van Meerbeek, Bart
To evaluate the influence of different surface treatments of six novel CAD/CAM materials on the bonding effectiveness of two luting composites. Six different CAD/CAM materials were tested: four ceramics - Vita Mark II; IPS Empress CAD and IPS e.max CAD; Celtra Duo - one hybrid ceramic, Vita Enamic, and one composite CAD/CAM block, Lava Ultimate. A total of 60 blocks (10 per material) received various mechanical surface treatments: 1. 600-grit SiC paper; 2. sandblasting with 30-μm Al2O3; 3. tribochemical silica coating (CoJet). Subsequent chemical surface treatments involved either no further treatment (control), HF acid etching (HF), silanization (S, or HF acid etching followed by silanization (HF+S). Two specimens with the same surface treatment were bonded together using two dual-curing luting composites: Clearfil Esthetic Cement (self-etching) or Panavia SA Cement (self-adhesive). After 1 week of water storage, the microtensile bond strength of the sectioned microspecimens was measured and the failure mode was evaluated. The bonding performance of the six CAD/CAM materials was significantly influenced by surface treatment (linear mixed models, p < 0.05). The luting cement had a significant influence on bond strength for Celtra Duo and Lava Ultimate (linear mixed models, p < 0.05). Mechanical surface treatment significantly influenced the bond strength for Celtra Duo (p = 0.0117), IPS e.max CAD (p = 0.0115), and Lava Ultimate (p < 0.0001). Different chemical surface treatments resulted in the highest bond strengths for the six CAD/CAM materials: Vita Mark II and IPS Empress CAD: S, HF+S; Celtra Duo: HF, HF+S; IPS e.max CAD: HF+S; Vita Enamic: HF+S, S. For Lava Ultimate, the highest bond strengths were obtained with HF, S, HF+S. Failure analysis showed a relation between bond strength and failure type: more mixed failures were observed with higher bond strengths. Mainly adhesive failures were noticed if no further surface treatment was done. The percentage of adhesive failures was higher for CAD/CAM materials with higher flexural strength (Celtra Duo, IPS e.max CAD, and Lava Ultimate). The bond strength of luting composites to novel CAD/CAM materials is influenced by surface treatment. For each luting composite, an adhesive cementation protocol can be specified in order to obtain the highest bond to the individual CAD/CAM materials.
Mieres, Jennifer H; Shaw, Leslee J; Hendel, Robert C; Heller, Gary V
2009-01-01
Coronary artery disease remains the leading cause of morbidity and mortality in women. The optimal non-invasive test for evaluation of ischemic heart disease in women is unknown. Although current guidelines support the choice of the exercise tolerance test (ETT) as a first line test for women with a normal baseline ECG and adequate exercise capabilities, supportive data for this recommendation are controversial. The what is the optimal method for ischemia evaluation in women? (WOMEN) study was designed to determine the optimal non-invasive strategy for CAD risk detection of intermediate and high risk women presenting with chest pain or equivalent symptoms suggestive of ischemic heart disease. The study will prospectively compare the 2-year event rates in women capable of performing exercise treadmill testing or Tc-99 m tetrofosmin SPECT myocardial perfusion imaging (MPI). The study will enroll women presenting for the evaluation of chest pain or anginal equivalent symptoms who are capable of performing >5 METs of exercise while at intermediate-high pretest risk for ischemic heart disease who will be randomized to either ETT testing alone or with Tc-99 m tetrofosmin SPECT MPI. The null hypothesis for this project is that the exercise ECG has the same negative predictive value for risk detection as gated myocardial perfusion SPECT in women. The primary aim is to compare 2-year cardiac event rates in women randomized to SPECT MPI to those randomized to ETT. The WOMEN study seeks to provide objective information for guidelines for the evaluation of symptomatic women with an intermediate-high likelihood for CAD.
Computerized Analysis of Digital Photographs for Evaluation of Tooth Movement
Toodehzaeim, Mohammad Hossein; Karandish, Maryam; Karandish, Mohammad Nabi
2015-01-01
Objectives: Various methods have been introduced for evaluation of tooth movement in orthodontics. The challenge is to adopt the most accurate and most beneficial method for patients. This study was designed to introduce analysis of digital photographs with AutoCAD software as a method to evaluate tooth movement and assess the reliability of this method. Materials and Methods: Eighteen patients were evaluated in this study. Three intraoral digital images from the buccal view were captured from each patient in half an hour interval. All the photos were sent to AutoCAD software 2011, calibrated and the distance between canine and molar hooks were measured. The data was analyzed using intraclass correlation coefficient. Results: Photographs were found to have high reliability coefficient (P > 0.05). Conclusion: The introduced method is an accurate, efficient and reliable method for evaluation of tooth movement. PMID:26622272
Two-body wear rate of CAD/CAM resin blocks and their enamel antagonists.
Stawarczyk, Bogna; Özcan, Mutlu; Trottmann, Albert; Schmutz, Felix; Roos, Malgorzata; Hämmerle, Christoph
2013-05-01
Computer-aided design and computer-aided manufacturing (CAD/CAM) resins exhibit good mechanical properties and can be used as long-term restorations. The wear rate of such resins and their enamel antagonists is unknown. The purpose of this study was to test and compare the 2-body wear rate of CAD/CAM resin blocks. Wear specimens (N=42, n=6) were made from 5 CAD/CAM resins: ZENO PMMA (ZP), artBloc Temp (AT), Telio CAD (TC), Blanc High-class (HC), CAD-Temp (CT); 1 manually polymerized resin: Integral esthetic press (negative control group, IEP); and 1 glass-ceramic: VITA Mark II (positive control group, VM2). The specimens for the wear resistance were aged in a thermomechanical loading machine (49 N, 1.67 Hz, 5/50°C) with human enamel antagonists. The material loss of all specimens before, during, and after aging was evaluated with a 3DS profilometer. The measured material loss data of all tested groups were statistically evaluated with linear mixed model analysis (a=.05). Manually polymerized resin showed significantly higher material wear (P<.001) than all other tested groups. Glass-ceramic showed significantly lower wear values (P<.001) than CAD/CAM resins ZP, AT, HC, CT, and IES. CAD/CAM resin TC was not significantly different from the positive control group. Glass-ceramic showed the highest enamel wear values (P<.001) of all tested resins. No differences were found in the enamel wear among all resins. The glass-ceramic group showed damage in the form of cracks on the worn enamel surface in 50% of specimens. CAD/CAM resins showed lower wear rates than those conventionally polymerized. Only one CAD/CAM resin, TC, presented material wear values comparable with glass-ceramic. The tested glass-ceramic developed cracks in the enamel antagonist and showed the highest enamel wear values of all other tested groups. Copyright © 2013 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.
Song, Yang; Zhao, Yi-jiao; Sun, Yu-chun; Lü, Pei-jun; Wang, Yong
2013-09-01
To evaluate the design and manufacture accuracy of a domestic computer aided design (CAD) and computer aided manufacture (CAM) system, and to compare it with similar foreign products. Thirty models of posterior-teeth-single-crown preparations were collected, and STL data of these preparations was collected by Denmark 3Shape scanner. Three copings were made for each preparation, the one designed and manufactured using commercial CAD/CAM system (3Shape CAD software and Wieland T1 CAM equipment) was assigned into control group T0, the one designed and manufactured using domestic CAD software (developed by Peking University School and Hospital of Stomatology and Nanjing University of Aeronautics and Astronautics) and Wieland T1 CAM equipment was assigned into experimental group TCAD for design accuracy evaluation, and the one designed and manufactured using 3Shape CAD software and domestic CAM equipment (developed by Peking University School and Hospital of Stomatology, Tsinghua University and ShanDong XinHua Incorporated Company of medical apparatus and instruments) was assigned into experimental group TCAM for manufacture accuracy evaluation. Finally, the marginal fitness were compared and evaluated by using 3D & Profile measurement microscope laser. The marginal fitness of TCAD was 27.98 (19.10, 46.57) µm in buccal, 32.67 (20.65, 50.82) µm in lingual, 27.38 (22.53, 52.61) µm in mesial, 29.50 (22.68, 53.65) µm in distal; of TCAM was 21.69 (15.87, 30.21) µm in buccal, 18.51 (13.50, 22.51) µm in lingual, 19.15 (15.42, 26.89) µm in mesial, 22.77 (18.58, 32.15) µm in distal; and there were no statistical differences compared with T0 [20.16 (17.16, 48.00) µm in buccal, 21.51 (17.05, 28.31) µm in lingual, 23.54 (17.89, 30.04) µm in mesial and 23.94 (17.93, 28.19) µm in distal] except lingual data of TCAD. The design and machining precision of this domestic CAD/CAM system is at the same level of those comparable foreign products.
2010-04-01
glycoproteins of Zaire ebolavirus (ZEBOV) and Sudan ebolavirus (SEBOV) in a single complex adenovirus -based vector (CAdVax). We evaluated our vaccine ...recombinant complex adenovirus vaccine (CAdVax) system, which provides multivalent protection of NHPs against multiple species of filoviruses (33). The...CAdVax vaccine platform is based on a complex, replication-defective adenovirus 5 (Ad5) vector (28–30, 37, 38) that allows for the incorporation of
Development of Smartphone Educational Application for Patients with Coronary Artery Disease
Cho, Min Jung; Sim, Jae Lan
2014-01-01
Objectives This study was conducted to develop a smartphone application (app) as an educational learning instrument for coronary artery disease (CAD) patients and to assess the users' level of satisfaction. Methods This methodological research involves elicited learning content for CAD patients to develop a learning instrument using the smartphone app. The app was developed according to the steps of Assessment, Design, Development, Implementation, and Evaluation, which is a systematic instructional design model. The levels of satisfaction with the developed smartphone app among 30 outpatients with CAD were assessed via a questionnaire during their visits to a cardiology outpatient department. Results A smartphone app 'Strong Heart' was developed through reviewing the literature associated with education for CAD patients under professional supervision and searching for medical smartphone apps that are already available. The learning contents include six main sections containing essential learning issues in managing CAD and additional information to attract the user's attention, such as patient cases and quizzes. After modification with feedback from experts, the app was finally developed and evaluated by patients who reported that they were satisfied with the usefulness of the app. Conclusions The developed smartphone app is available on both the iPhone App Store and the Android Play Store. Patients with CAD may utilize the app for supporting educational material without limitations of time and space. PMID:24872910
Tourassi, Georgia D; Harrawood, Brian; Singh, Swatee; Lo, Joseph Y; Floyd, Carey E
2007-01-01
The purpose of this study was to evaluate image similarity measures employed in an information-theoretic computer-assisted detection (IT-CAD) scheme. The scheme was developed for content-based retrieval and detection of masses in screening mammograms. The study is aimed toward an interactive clinical paradigm where physicians query the proposed IT-CAD scheme on mammographic locations that are either visually suspicious or indicated as suspicious by other cuing CAD systems. The IT-CAD scheme provides an evidence-based, second opinion for query mammographic locations using a knowledge database of mass and normal cases. In this study, eight entropy-based similarity measures were compared with respect to retrieval precision and detection accuracy using a database of 1820 mammographic regions of interest. The IT-CAD scheme was then validated on a separate database for false positive reduction of progressively more challenging visual cues generated by an existing, in-house mass detection system. The study showed that the image similarity measures fall into one of two categories; one category is better suited to the retrieval of semantically similar cases while the second is more effective with knowledge-based decisions regarding the presence of a true mass in the query location. In addition, the IT-CAD scheme yielded a substantial reduction in false-positive detections while maintaining high detection rate for malignant masses.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tourassi, Georgia D.; Harrawood, Brian; Singh, Swatee
The purpose of this study was to evaluate image similarity measures employed in an information-theoretic computer-assisted detection (IT-CAD) scheme. The scheme was developed for content-based retrieval and detection of masses in screening mammograms. The study is aimed toward an interactive clinical paradigm where physicians query the proposed IT-CAD scheme on mammographic locations that are either visually suspicious or indicated as suspicious by other cuing CAD systems. The IT-CAD scheme provides an evidence-based, second opinion for query mammographic locations using a knowledge database of mass and normal cases. In this study, eight entropy-based similarity measures were compared with respect to retrievalmore » precision and detection accuracy using a database of 1820 mammographic regions of interest. The IT-CAD scheme was then validated on a separate database for false positive reduction of progressively more challenging visual cues generated by an existing, in-house mass detection system. The study showed that the image similarity measures fall into one of two categories; one category is better suited to the retrieval of semantically similar cases while the second is more effective with knowledge-based decisions regarding the presence of a true mass in the query location. In addition, the IT-CAD scheme yielded a substantial reduction in false-positive detections while maintaining high detection rate for malignant masses.« less
Microhardness evaluations of CAD/CAM ceramics irradiated with CO2 or Nd:YAP laser
Rocca, Jean Paul; Fornaini, Carlo; Medioni, Etienne; Brulat-Bouchard, Nathalie
2017-01-01
Background and aims The aim of this study was to measure the microhardness values of irradiated computer-aided design/computer-aided manufacturing (CAD/CAM) ceramics surfaces before and after thermal treatment. Materials and Methods Sixty CAD/CAM ceramic discs were prepared and grouped by material, i.e. lithium disilicate ceramic (Emax CAD) and zirconia ceramic (Emax ZirCAD). Laser irradiation at the material surface was performed with a carbon dioxide laser at 5 Watt (W) or 10 W power in continuous mode (CW mode), or with a neodymium:yttrium aluminum perovskite (Nd:YAP) laser at 10 W on graphite and non-graphite surfaces. Vickers hardness was tested at 0.3 kgf for lithium disilicate and 1 kgf for zirconia. Results Emax CAD irradiated with CO2 at 5 W increased microhardness by 6.32 GPa whereas Emax ZirCAD irradiated with Nd:YAP decreased microhardness by 17.46 GPa. Conclusion CO2 laser effectively increases the microhardness of lithium disilicate ceramics (Emax CAD). PMID:28740324
Different CAD/CAM-processing routes for zirconia restorations: influence on fitting accuracy.
Kohorst, Philipp; Junghanns, Janet; Dittmer, Marc P; Borchers, Lothar; Stiesch, Meike
2011-08-01
The aim of the present in vitro study was to evaluate the influence of different processing routes on the fitting accuracy of four-unit zirconia fixed dental prostheses (FDPs) fabricated by computer-aided design/computer-aided manufacturing (CAD/CAM). Three groups of zirconia frameworks with ten specimens each were fabricated. Frameworks of one group (CerconCAM) were produced by means of a laboratory CAM-only system. The other frameworks were made with different CAD/CAM systems; on the one hand by in-laboratory production (CerconCAD/CAM) and on the other hand by centralized production in a milling center (Compartis) after forwarding geometrical data. Frameworks were then veneered with the recommended ceramics, and marginal accuracy was determined using a replica technique. Horizontal marginal discrepancy, vertical marginal discrepancy, absolute marginal discrepancy, and marginal gap were evaluated. Statistical analyses were performed by one-way analysis of variance (ANOVA), with the level of significance chosen at 0.05. Mean horizontal discrepancies ranged between 22 μm (CerconCAM) and 58 μm (Compartis), vertical discrepancies ranged between 63 μm (CerconCAD/CAM) and 162 μm (CerconCAM), and absolute marginal discrepancies ranged between 94 μm (CerconCAD/CAM) and 181 μm (CerconCAM). The marginal gap varied between 72 μm (CerconCAD/CAM) and 112 μm (CerconCAM, Compartis). Statistical analysis revealed that, with all measurements, the marginal accuracy of the zirconia FDPs was significantly influenced by the processing route used (p < 0.05). Within the limitations of this study, all restorations showed a clinically acceptable marginal accuracy; however, the results suggest that the CAD/CAM systems are more precise than the CAM-only system for the manufacture of four-unit FDPs.
Genetic loci associated with nonobstructive coronary artery disease in Caucasian women.
Weng, Liming; Taylor, Kent D; Chen, Yii-Der Ida; Sopko, George; Kelsey, Sheryl F; Bairey Merz, C Noel; Pepine, Carl J; Miller, Virginia M; Rotter, Jerome I; Gulati, Martha; Goodarzi, Mark O; Cooper-DeHoff, Rhonda M
2016-01-01
Nonobstructive coronary artery disease (CAD) in women is associated with adverse cardiovascular (CV) outcomes; however, information regarding genetic variants that predispose women to nonobstructive CAD is lacking. Women from the Women's Ischemia Syndrome Evaluation (WISE) Study and the St. James Women Take Heart (WTH) Study were genotyped with the Cardio-MetaboChip. WISE enrolled women with symptoms and signs of ischemia referred for coronary angiography; WTH enrolled asymptomatic, community-based women without heart disease. Analyses were conducted with a case (WISE)--control (WTH) design and multivariate logistic regression models to investigate genetic variation associated with likelihood of nonobstructive CAD. One genetic marker, single nucleotide polymorphism (SNP) rs2301753 on chromosome 6 in RNF39, achieved chip-wide significance for nonobstructive CAD (P < 9.5 × 10(-7)). After adjusting for baseline characteristics, we found no variants achieved chip-wide significance. However, SNP rs2301753 on chromosome 6 in RNF39 was associated with reduced likelihood of nonobstructive CAD [odds ratio (OR) 0.42 and 95% confidence interval (CI) of 0.29 to 0.68], at a nominal level of P = 5.6 × 10(-6), while SNP rs12818945 in the ATP2B1 locus on chromosome 12 was associated with increased odds for nonobstructive CAD (OR 2.38 and 95% CI of 1.63 to 3.45) and nominal P = 5.8 × 10(-6). The functions of RNF39 and ATP2B1 raise the possibility that genes involved in cardio-dysfunction may contribute to nonobstructive CAD in Caucasian women and may provide insights into novel approaches for therapy and prevention. If replicated, incorporation of these genetic variants into diagnostic evaluation may identify women at high risk for nonobstructive CAD.
Cazelli, José Guilherme; Camargo, Gabriel Cordeiro; Kruczan, Dany David; Weksler, Clara; Felipe, Alexandre Rouge; Gottlieb, Ilan
2017-10-01
The prevalence of coronary artery disease (CAD) in valvular patients is similar to that of the general population, with the usual association with traditional risk factors. Nevertheless, the search for obstructive CAD is more aggressive in the preoperative period of patients with valvular heart disease, resulting in the indication of invasive coronary angiography (ICA) to almost all adult patients, because it is believed that coronary artery bypass surgery should be associated with valve replacement. To evaluate the prevalence of obstructive CAD and factors associated with it in adult candidates for primary heart valve surgery between 2001 and 2014 at the National Institute of Cardiology (INC) and, thus, derive and validate a predictive obstructive CAD score. Cross-sectional study evaluating 2898 patients with indication for heart surgery of any etiology. Of those, 712 patients, who had valvular heart disease and underwent ICA in the 12 months prior to surgery, were included. The P value < 0.05 was adopted as statistical significance. The prevalence of obstructive CAD was 20%. A predictive model of obstructive CAD was created from multivariate logistic regression, using the variables age, chest pain, family history of CAD, systemic arterial hypertension, diabetes mellitus, dyslipidemia, smoking, and male gender. The model showed excellent correlation and calibration (R² = 0.98), as well as excellent accuracy (ROC of 0.848; 95%CI: 0.817-0.879) and validation (ROC of 0.877; 95%CI: 0.830 - 0.923) in different valve populations. Obstructive CAD can be estimated from clinical data of adult candidates for valve repair surgery, using a simple, accurate and validated score, easy to apply in clinical practice, which may contribute to changes in the preoperative strategy of acquired heart valve surgery in patients with a lower probability of obstructive disease.
NASA Astrophysics Data System (ADS)
Litjens, G. J. S.; Barentsz, J. O.; Karssemeijer, N.; Huisman, H. J.
2012-03-01
MRI has shown to have great potential in prostate cancer localization and grading, but interpreting those exams requires expertise that is not widely available. Therefore, CAD applications are being developed to aid radiologists in detecting prostate cancer. Existing CAD applications focus on the prostate as a whole. However, in clinical practice transition zone cancer and peripheral zone cancer are considered to have different appearances. In this paper we present zone-specific CAD, in addition to an atlas based segmentation technique which includes zonal segmentation. Our CAD system consists of a detection and a classification stage. Prior to the detection stage the prostate is segmented into two zones. After segmentation features are extracted. Subsequently a likelihood map is generated on which local maxima detection is performed. For each local maximum a region is segmented. In the classification stage additional shape features are calculated, after which the regions are classified. Validation was performed on 288 data sets with MR-guided biopsy results as ground truth. Freeresponse Receiver Operating Characteristic (FROC) analysis was used for statistical evaluation. The difference between whole-prostate and zone-specific CAD was assessed using the difference between the FROCs. Our results show that evaluating the two zones separately results in an increase in performance compared to whole-prostate CAD. The FROC curves at .1, 1 and 3 false positives have a sensitivity of 0.0, 0.55 and 0.72 for whole-prostate and 0.08, 0.57 and 0.80 for zone-specific CAD. The FROC curve of the zone-specific CAD also showed significantly better performance overall (p < 0.05).
Andreini, Daniele; Pontone, Gianluca; Mushtaq, Saima; Gransar, Heidi; Conte, Edoardo; Bartorelli, Antonio L; Pepi, Mauro; Opolski, Maksymilian P; Ó Hartaigh, Bríain; Berman, Daniel S; Budoff, Matthew J; Achenbach, Stephan; Al-Mallah, Mouaz; Cademartiri, Filippo; Callister, Tracy Q; Chang, Hyuk-Jae; Chinnaiyan, Kavitha; Chow, Benjamin J W; Cury, Ricardo; Delago, Augustin; Hadamitzky, Martin; Hausleiter, Joerg; Feuchtner, Gudrun; Kim, Yong-Jin; Kaufmann, Philipp A; Leipsic, Jonathon; Lin, Fay Y; Maffei, Erica; Raff, Gilbert; Shaw, Leslee J; Villines, Todd C; Dunning, Allison; Marques, Hugo; Rubinshtein, Ronen; Hindoyan, Niree; Gomez, Millie; Min, James K
2017-03-15
Non-obstructive coronary artery disease (CAD) identified by coronary computed tomography angiography (CCTA) demonstrated prognostic value. CT-adapted Leaman score (CT-LeSc) showed to improve the prognostic stratification. Aim of the study was to evaluate the capability of CT-LeSc to assess long-term prognosis of patients with non-obstructive (CAD). From 17 centers, we enrolled 2402 patients without prior CAD history who underwent CCTA that showed non-obstructive CAD and provided complete information on plaque composition. Patients were divided into a group without CAD and a group with non-obstructive CAD (<50% stenosis). Segment-involvement score (SIS) and CT-LeSc were calculated. Outcomes were non-fatal myocardial infarction (MI) and the combined end-point of MI and all-cause mortality. Patient mean age was 56±12years. At follow-up (mean 59.8±13.9months), 183 events occurred (53 MI, 99 all-cause deaths and 31 late revascularizations). CT-LeSc was the only multivariate predictor of MI (HRs 2.84 and 2.98 in two models with Framingham and risk factors, respectively) and of MI plus all-cause mortality (HR 2.48 and 1.94 in two models with Framingham and risk factors, respectively). This was confirmed by a net reclassification analysis confirming that the CT-LeSc was able to correctly reclassify a significant proportion of patients (cNRI 0.28 and 0.23 for MI and MI plus all-cause mortality, respectively) vs. baseline model, whereas SIS did not. CT-LeSc is an independent predictor of major acute cardiac events, improving prognostic stratification of patients with non-obstructive CAD. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Computer-aided diagnosis: A survey with bibliometric analysis.
Takahashi, Ryohei; Kajikawa, Yuya
2017-05-01
Computer-aided diagnosis (CAD) has been a promising area of research over the last two decades. However, CAD is a very complicated subject because it involves a number of medicine and engineering-related fields. To develop a research overview of CAD, we conducted a literature survey with bibliometric analysis, which we report here. Our study determined that CAD research has been classified and categorized according to disease type and imaging modality. This classification began with the CAD of mammograms and eventually progressed to that of brain disease. Furthermore, based on our results, we discuss future directions and opportunities for CAD research. First, in contrast to the typical hypothetical approach, the data-driven approach has shown promise. Second, the normalization of the test datasets and an evaluation method is necessary when adopting an algorithm and a system. Third, we discuss opportunities for the co-evolution of CAD research and imaging instruments-for example, the CAD of bones and pancreatic cancer. Fourth, the potential of synergy with CAD and clinical decision support systems is also discussed. Copyright © 2017 Elsevier B.V. All rights reserved.
Matching tire tracks on the head using forensic photogrammetry.
Thali, M J; Braun, M; Brüschweiler, W; Dirnhofer, R
2000-09-11
In the field of the documentation of forensics-relevant injuries, from the reconstructive point of view, the forensic, CAD-supported photogrammetry plays an important role; particularly so when a detailed 3-D reconstruction is vital. This is demonstrated with a soft-tissue injury to the face caused by being run over by a car tire. Since the objects (injury and surface of the tire) to be investigated will be evaluated in virtual space, they must be series photographed. These photo sequences are then evaluated with the RolleiMetric multi-image evaluation system. This system measures and calculates the spatial location of points shown in the photo sequences, and creates 3-D data models of the objects. In a 3-D CAD program, the model of the injury is then compared against the model of the possible injury-causing instrument. The validation of the forensic, CAD-supported photogrammetry, as shown by the perfect 3-D match between the tire tread and the facial injury, demonstrates how greatly this 3-D method surpasses the classic 2-D overlay method (one-to-one photography).
NASA Astrophysics Data System (ADS)
Gabor, A.; Jivanescu, A.; Zaharia, C.; Hategan, S.; Topala, F. I.; Levai, C. M.; Negrutiu, M. L.; Sinescu, C.; Duma, V.-F.; Bradu, A.; Podoleanu, A. Gh.
2016-03-01
Digital impressions were introduced to overcome some of the obstacles due to traditional impression materials and techniques. The aim of this in vitro study is to compare the accuracy of all ceramic crowns obtained with digital impression and CAD-CAM technology with the accuracy of those obtained with conventional impression techniques. Two groups of 10 crowns each have been considered. The digital data obtained from Group 1 have been processed and the all-ceramic crowns were milled with a CAD/CAM technology (CEREC MCX, Sirona). The all ceramic crowns in Group 2 were obtained with the classical technique of pressing (emax, Ivoclar, Vivadent). The evaluation of the marginal adaptation was performed with Time Domain Optical Coherence Tomography (TD OCT), working at a wavelength of 1300 nm. Tri-dimensional (3D) reconstructions of the selected areas were obtained. Based on the findings in this study, one may conclude that the marginal accuracy of all ceramic crowns fabricated with digital impression and the CAD/CAM technique is superior to the conventional impression technique.
Insulin resistance and coronary artery disease in non-diabetic patients: Is there any correlation?
Vafaeimanesh, Jamshid; Parham, Mahmoud; Norouzi, Samieh; Hamednasimi, Parinaz; Bagherzadeh, Mohammad
2018-01-01
Cardiovascular diseases are the most common causes of death in the world and type 2 diabetes is one of them because it is highly prevalent and doubles heart disease risk. Some studies suggest that insulin resistance is associated with coronary artery disease in non-diabetics. The aim of this study was to evaluate the association of insulin resistance (IR) and coronary artery disease (CAD) in non-diabetic patients. In this cross-sectional study, from September 2014 to July 2015, 120 patients referring to Shahid Beheshti Hospital of Qom were evaluated. Their medical history, baseline laboratory studies, BMI and GFR were recorded. After 8 hours of fasting, blood samples were taken from the patients at 8 am, including fasting glucose and insulin level. We estimated insulin resistance using the homeostatic model assessment index of IR (HOMA-IR). Finally, we evaluated the association between IR and CAD. Totally, 120 patients were assigned to participate in this study, among them, 50 patients without CAD and 70 with coronary artery stenosis. Insulin resistance (HOMA-IR> 2.5) was positive in 59 (49.3%) patients and negative in 61 (50.7%) patients. Hence, the correlation between IR and CAD was not statistically significant (P=0.9). In this study, although the correlation was not found between insulin resistance and coronary heart disease, among men, we found a significant association between coronary heart disease and insulin resistance.
Lin, Tai-Min; Liu, Perng-Ru; Ramp, Lance C; Essig, Milton E; Givan, Daniel A; Pan, Yu-Hwa
2012-03-01
The purpose of this investigation is to evaluate marginal discrepancy and fracture resistance of two veneering materials using two preparation designs. Two veneer preparation designs (full and traditional) were restored with leucite-reinforced ceramic (ProCAD, Ivoclar Vivadent, Amherst, NY) milled by CAD/CAM (Cerec 3D milling system, Serona Dental Systems), and conventional sintered feldspathic porcelain (Noritake Super Porcelain EX3, Noritake Dental Supply Co). Forty-eight specimens were analysed with a sample size of n=12 per group. The thickness of each veneer was measured on four specific surfaces. Marginal discrepancy was evaluated with a replica technique and cross-sectional view using a digital microscope. The fracture resistance of veneers cemented on standardised composite resin dies was evaluated using a universal testing machine. Results were analysed with ANOVA, Tukey-Kramer post hoc testing, and linear regression. The results of this investigation revealed no correlation between the thickness and marginal discrepancy of the veneers. The full preparation design with ProCAD and the traditional preparation design with feldspathic porcelain manifested smaller gap. Fracture resistance was decreased for the full preparation design with feldspathic porcelain. In terms of marginal discrepancy and fracture resistance, the most favourable combination was a traditional veneer preparation design with conventional sintered feldspathic porcelain. For the full veneer preparation, a stronger ceramic material such as ProCAD is suggested. Published by Elsevier Ltd.
Zimmermann, Moritz; Koller, Christina; Mehl, Albert; Hickel, Reinhard
2017-01-01
No clinical data are available for the new computer-aided design/computer-assisted manufacture (CAD/CAM) material zirconia-reinforced lithium silicate (ZLS) ceramic. This study describes preliminary clinical results for indirect ZLS CAD/CAM restorations after 12 months. Indirect restorations were fabricated, using the CEREC method and intraoral scanning (CEREC Omnicam, CEREC MCXL). Sixty-seven restorations were seated adhesively (baseline). Sixty restorations were evaluated after 12 months (follow-up), using modified FDI criteria. Two groups were established, according to ZLS restorations' post-processing procedure prior to adhesive seating: group I (three-step polishing, n = 32) and group II (fire glazing, n = 28). Statistical analysis was performed with Mann-Whitney U test and Wilcoxon test (P < .05). The success rate of indirect ZLS CAD/CAM restorations after 12 months was 96.7%. Two restorations clinically failed as a result of bulk fracture (failure rate 3.3%). No statistically significant differences were found for baseline and follow-up criteria (Wilcoxon test, P > .05). Statistically significant differences were found for criteria surface gloss for group I and group II (Mann-Whitney U test, P < .05). This study demonstrates ZLS CAD/CAM restorations have a high clinical success rate after 12 months. A longer clinical evaluation period is necessary to draw further conclusions.
The effect of various veneering techniques on the marginal fit of zirconia copings
Torabi, Kianoosh; Vojdani, Mahroo; Giti, Rashin; Pardis, Soheil
2015-01-01
PURPOSE This study aimed to evaluate the fit of zirconia ceramics before and after veneering, using 3 different veneering processes (layering, press-over, and CAD-on techniques). MATERIALS AND METHODS Thirty standardized zirconia CAD/CAM frameworks were constructed and divided into three groups of 10 each. The first group was veneered using the traditional layering technique. Press-over and CAD-on techniques were used to veneer second and third groups. The marginal gap of specimens was measured before and after veneering process at 18 sites on the master die using a digital microscope. Paired t-test was used to evaluate mean marginal gap changes. One-way ANOVA and post hoc tests were also employed for comparison among 3 groups (α=.05). RESULTS Marginal gap of 3 groups was increased after porcelain veneering. The mean marginal gap values after veneering in the layering group (63.06 µm) was higher than press-over (50.64 µm) and CAD-on (51.50 µm) veneered groups (P<.001). CONCLUSION Three veneering methods altered the marginal fit of zirconia copings. Conventional layering technique increased the marginal gap of zirconia framework more than pressing and CAD-on techniques. All ceramic crowns made through three different veneering methods revealed clinically acceptable marginal fit. PMID:26140175
Baker, Mark E; Bogoni, Luca; Obuchowski, Nancy A; Dass, Chandra; Kendzierski, Renee M; Remer, Erick M; Einstein, David M; Cathier, Pascal; Jerebko, Anna; Lakare, Sarang; Blum, Andrew; Caroline, Dina F; Macari, Michael
2007-10-01
To determine whether computer-aided detection (CAD) applied to computed tomographic (CT) colonography can help improve sensitivity of polyp detection by less-experienced radiologist readers, with colonoscopy or consensus used as the reference standard. The release of the CT colonographic studies was approved by the individual institutional review boards of each institution. Institutions from the United States were HIPAA compliant. Written informed consent was waived at all institutions. The CT colonographic studies in 30 patients from six institutions were collected; 24 images depicted at least one confirmed polyp 6 mm or larger (39 total polyps) and six depicted no polyps. By using an investigational software package, seven less-experienced readers from two institutions evaluated the CT colonographic images and marked or scored polyps by using a five-point scale before and after CAD. The time needed to interpret the CT colonographic findings without CAD and then to re-evaluate them with CAD was recorded. For each reader, the McNemar test, adjusted for clustered data, was used to compare sensitivities for readers without and with CAD; a Wilcoxon signed-rank test was used to analyze the number of false-positive results per patient. The average sensitivity of the seven readers for polyp detection was significantly improved with CAD-from 0.810 to 0.908 (P=.0152). The number of false-positive results per patient without and with CAD increased from 0.70 to 0.96 (95% confidence interval for the increase: -0.39, 0.91). The mean total time for the readings was 17 minutes 54 seconds; for interpretation of CT colonographic findings alone, the mean time was 14 minutes 16 seconds; and for review of CAD findings, the mean time was 3 minutes 38 seconds. Results of this feasibility study suggest that CAD for CT colonography significantly improves per-polyp detection for less-experienced readers. Copyright (c) RSNA, 2007.
Li, Min; Du, Xiang-Min; Jin, Zhi-Tao; Peng, Zhao-Hui; Ding, Juan; Li, Li
2014-01-01
To comprehensively investigate the diagnostic performance of coronary artery angiography with 64-MDCT and post 64-MDCT. PubMed was searched for all published studies that evaluated coronary arteries with 64-MDCT and post 64-MDCT. The clinical diagnostic role was evaluated by applying the likelihood ratios (LRs) to calculate the post-test probability based on Bayes' theorem. 91 studies that met our inclusion criteria were ultimately included in the analysis. The pooled positive and negative LRs at patient level were 8.91 (95% CI, 7.53, 10.54) and 0.02 (CI, 0.01, 0.03), respectively. For studies that did not claim that non-evaluable segments were included, the pooled positive and negative LRs were 11.16 (CI, 8.90, 14.00) and 0.01 (CI, 0.01, 0.03), respectively. For studies including uninterruptable results, the diagnostic performance decreased, with the pooled positive LR 7.40 (CI, 6.00, 9.13) and negative LR 0.02 (CI, 0.01, 0.03). The areas under the summary ROC curve were 0.98 (CI, 0.97 to 0.99) for 64-MDCT and 0.96 (CI, 0.94 to 0.98) for post 64-MDCT, respectively. For references explicitly stating that the non-assessable segments were included during analysis, a post-test probability of negative results >95% and a positive post-test probability <95% could be obtained for patients with a pre-test probability of <73% for coronary artery disease (CAD). On the other hand, when the pre-test probability of CAD was >73%, the diagnostic role was reversed, with a positive post-test probability of CAD >95% and a negative post-test probability of CAD <95%. The diagnostic performance of post 64-MDCT does not increase as compared with 64-MDCT. CTA, overall, is a test of exclusion for patients with a pre-test probability of CAD<73%, while for patients with a pre-test probability of CAD>73%, CTA is a test used to confirm the presence of CAD.
Moschetti, Karine; Muzzarelli, Stefano; Pinget, Christophe; Wagner, Anja; Pilz, Günther; Wasserfallen, Jean-Blaise; Schulz-Menger, Jeanette; Nothnagel, Detle; Dill, Torsten; Frank, Herbert; Lombardi, Massimo; Bruder, Oliver; Mahrholdt, Heiko; Schwitter, Jürg
2012-06-14
Cardiovascular magnetic resonance (CMR) has favorable characteristics for diagnostic evaluation and risk stratification of patients with known or suspected CAD. CMR utilization in CAD detection is growing fast. However, data on its cost-effectiveness are scarce. The goal of this study is to compare the costs of two strategies for detection of significant coronary artery stenoses in patients with suspected coronary artery disease (CAD): 1) Performing CMR first to assess myocardial ischemia and/or infarct scar before referring positive patients (defined as presence of ischemia and/or infarct scar to coronary angiography (CXA) versus 2) a hypothetical CXA performed in all patients as a single test to detect CAD. A subgroup of the European CMR pilot registry was used including 2,717 consecutive patients who underwent stress-CMR. From these patients, 21% were positive for CAD (ischemia and/or infarct scar), 73% negative, and 6% uncertain and underwent additional testing. The diagnostic costs were evaluated using invoicing costs of each test performed. Costs analysis was performed from a health care payer perspective in German, United Kingdom, Swiss, and United States health care settings. In the public sectors of the German, United Kingdom, and Swiss health care systems, cost savings from the CMR-driven strategy were 50%, 25% and 23%, respectively, versus outpatient CXA. If CXA was carried out as an inpatient procedure, cost savings were 46%, 50% and 48%, respectively. In the United States context, cost savings were 51% when compared with inpatient CXA, but higher for CMR by 8% versus outpatient CXA. This analysis suggests that from an economic perspective, the use of CMR should be encouraged as a management option for patients with suspected CAD.
Gueret, Pascal; Deux, Jean-François; Bonello, Laurent; Sarran, Anthony; Tron, Christophe; Christiaens, Luc; Dacher, Jean-Nicolas; Bertrand, David; Leborgne, Laurent; Renard, Cedric; Caussin, Christophe; Cluzel, Philippe; Helft, Gerard; Crochet, Dominique; Vernhet-Kovacsik, Hélène; Chabbert, Valérie; Ferrari, Emile; Gilard, Martine; Willoteaux, Serge; Furber, Alain; Barone-Rochette, Gilles; Jankowski, Adrien; Douek, Philippe; Mousseaux, Elie; Sirol, Marc; Niarra, Ralph; Chatellier, Gilles; Laissy, Jean-Pierre
2013-02-15
Computed tomographic coronary angiography (CTCA) has been proposed as a noninvasive test for significant coronary artery disease (CAD), but only limited data are available from prospective multicenter trials. The goal of this study was to establish the diagnostic accuracy of CTCA compared to coronary angiography (CA) in a large population of symptomatic patients with clinical indications for coronary imaging. This national, multicenter study was designed to prospectively evaluate stable patients able to undergo CTCA followed by conventional CA. Data from CTCA and CA were analyzed in a blinded fashion at central core laboratories. The main outcome was the evaluation of patient-, vessel-, and segment-based diagnostic performance of CTCA to detect or rule out significant CAD (≥50% luminal diameter reduction). Of 757 patients enrolled, 746 (mean age 61 ± 12 years, 71% men) were analyzed. They underwent CTCA followed by CA 1.7 ± 0.8 days later using a 64-detector scanner. The prevalence of significant CAD in native coronary vessels by CA was 54%. The rate of nonassessable segments by CTCA was 6%. In a patient-based analysis, sensitivity, specificity, positive and negative predictive values, and positive and negative likelihood ratios of CTCA were 91%, 50%, 68%, 83%, 1.82, and 0.18, respectively. The strongest predictors of false-negative results on CTCA were high estimated pretest probability of CAD (odds ratio [OR] 1.97, p <0.001), male gender (OR 1.5, p <0.002), diabetes (OR 1.5, p <0.0001), and age (OR 1.2, p <0.0001). In conclusion, in this large multicenter study, CTCA identified significant CAD with high sensitivity. However, in routine clinical practice, each patient should be individually evaluated, and the pretest probability of obstructive CAD should be taken into account when deciding which method, CTCA or CA, to use to diagnose its presence and severity. Copyright © 2013 Elsevier Inc. All rights reserved.
Coronary risk stratification of patients undergoing surgery for valvular heart disease.
Hasselbalch, Rasmus Bo; Engstrøm, Thomas; Pries-Heje, Mia; Heitmann, Merete; Pedersen, Frants; Schou, Morten; Mickley, Hans; Elming, Hanne; Steffensen, Rolf; Køber, Lars; Iversen, Kasper
2017-01-15
Multislice computed tomography (MSCT) is a non-invasive, less expensive, low-radiation alternative to coronary angiography (CAG) prior to valvular heart surgery. MSCT has a high negative predictive value for coronary artery disease (CAD) but previous studies of patients with valvular disease have shown that MSCT, as the primary evaluation technique, lead to re-evaluation with CAG in about a third of cases and it is therefore not recommended. If a subgroup of patients with low- to intermediate risk of CAD could be identified and examined with MSCT, it could be cost-effective, reduce radiation and the risk of complications associated with CAG. The study cohort was derived from a national registry of patients undergoing CAG prior to valvular heart surgery. Using logistic regression, we identified significant risk factors for CAD and developed a risk score (CT-valve score). The score was validated on a similar cohort of patients from another registry. The study cohort consisted of 2221 patients, 521 (23.5%) had CAD. The validation cohort consisted of 2575 patients, 771 (29.9%) had CAD. The identified risk factors were male sex, age, smoking, hyperlipidemia, hypertension, aortic valve disease, extracardiac arteriopathy, ejection fraction <30% and diabetes mellitus. CT-valve score could identify a third of the population with a risk about 10%. A score based on risk factors of CAD can identify patients that might benefit from using MSCT as a gatekeeper to CAG prior to heart valve surgery. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Zimmermann, M; Valcanaia, A; Neiva, G; Mehl, A; Fasbinder, D
2018-04-09
CAM fabrication is an important step within the CAD/CAM process. The internal fit of restorations is influenced by the accuracy of the subtractive CAM procedure. Little is known about how CAM strategies might influence the fit of CAD/CAM fabricated restorations. The aim of this study was to three-dimensionally evaluate the fit of CAD/CAM fabricated zirconia-reinforced lithium silicate ceramic partial crowns fabricated with three different CAM strategies. The null hypothesis was that different CAM strategies did not influence the fitting accuracy of CAD/CAM fabricated zirconia-reinforced lithium silicate ceramic partial crowns. Preparation for a partial crown was performed on a maxillary right first molar on a typodont. A chairside CAD/CAM system with the intraoral scanning device CEREC Omnicam (Dentsply Sirona, York, PA, USA) and the 3+1 axis milling unit CEREC MCXL was used. There were three groups with different CAM strategies: step bur 12 (12), step bur 12S (12S), and two step-mode (12TWO). The zirconia-reinforced lithium silicate ceramic Celtra Duo (Dentsply Sirona) was used as the CAD/CAM material. A new 3D method for evaluating the fit was applied, consisting of the quadrant scan with the intraoral scanning device CEREC Omnicam. The scan of the PVS material adherent to the preparation and the preparation scan were matched, and the difference analysis was performed with special software OraCheck (Cyfex AG, Zurich, Switzerland). Three areas were selected for analysis: margin (MA), axial (AX), and occlusal (OC). Statistical analysis was performed using 80% percentile, one-way ANOVA, and the post hoc Scheffé test with α=0.05. Statistically significant differences were found both within and between the test groups. The aspect axial fit results varied from 90.5 ± 20.1 μm for the two-step milling mode (12TWO_AX) to 122.8 ± 12.2 μm for the milling with step bur 12S (12S_AX). The worst result in all groups was found for the aspect occlusal fit with the highest value for group 12S of 222.8 ± 35.6 μm. Group two-step milling mode (12TWO) performed statistically significantly better from groups 12 and 12S for the occlusal fit ( p<0.05). Deviation patterns were visually analyzed with a color-coded scheme for each restoration. CAM strategy influenced the internal adaptation of zirconia-reinforced lithium silicate partial crowns fabricated with a chairside CAD/CAM system. Sensible selection of specific areas of internal adaptation and fit is an important factor for evaluating the CAM accuracy of CAD/CAM systems.
Rationale for the Use of CAD/CAM Technology in Implant Prosthodontics
Abduo, Jaafar; Lyons, Karl
2013-01-01
Despite the predictable longevity of implant prosthesis, there is an ongoing interest to continue to improve implant prosthodontic treatment and outcomes. One of the developments is the application of computer-aided design and computer-aided manufacturing (CAD/CAM) to produce implant abutments and frameworks from metal or ceramic materials. The aim of this narrative review is to critically evaluate the rationale of CAD/CAM utilization for implant prosthodontics. To date, CAD/CAM allows simplified production of precise and durable implant components. The precision of fit has been proven in several laboratory experiments and has been attributed to the design of implants. Milling also facilitates component fabrication from durable and aesthetic materials. With further development, it is expected that the CAD/CAM protocol will be further simplified. Although compelling clinical evidence supporting the superiority of CAD/CAM implant restorations is still lacking, it is envisioned that CAD/CAM may become the main stream for implant component fabrication. PMID:23690778
Expression of IL-33 in chronic lesional skin of canine atopic dermatitis.
Asahina, Ryota; Nishida, Hidetaka; Kamishina, Hiroaki; Maeda, Sadatoshi
2018-06-01
In humans, interleukin (IL)-33 plays a critical role in the enhancement of allergic skin inflammation. However, it currently remains unclear whether IL-33 is involved in the pathogenesis of canine atopic dermatitis (cAD). To examine the expression of IL-33 in chronic lesional skin of cAD. Eight dogs with spontaneous cAD and five healthy dogs were used. The transcription of il-33 in chronic lesional skin of cAD was quantified by quantitative reverse transcription PCR. The expression of IL-33 was evaluated immunohistochemically using an anti-human IL-33 monoclonal antibody with cross-reactivity to canine IL-33. The transcription levels of il-33 in chronic lesional skin of cAD were significantly higher than those in normal skin of healthy dogs. Keratinocytes were a major cellular source of IL-33 production in chronic lesional skin of cAD. The results indicate that IL-33 is involved in chronic lesional skin of cAD. © 2018 ESVD and ACVD.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li Ping; Napel, Sandy; Acar, Burak
2004-10-01
Computed tomography colonography (CTC) is a minimally invasive method that allows the evaluation of the colon wall from CT sections of the abdomen/pelvis. The primary goal of CTC is to detect colonic polyps, precursors to colorectal cancer. Because imperfect cleansing and distension can cause portions of the colon wall to be collapsed, covered with water, and/or covered with retained stool, patients are scanned in both prone and supine positions. We believe that both reading efficiency and computer aided detection (CAD) of CTC images can be improved by accurate registration of data from the supine and prone positions. We developed amore » two-stage approach that first registers the colonic central paths using a heuristic and automated algorithm and then matches polyps or polyp candidates (CAD hits) by a statistical approach. We evaluated the registration algorithm on 24 patient cases. After path registration, the mean misalignment distance between prone and supine identical anatomic landmarks was reduced from 47.08 to 12.66 mm, a 73% improvement. The polyp registration algorithm was specifically evaluated using eight patient cases for which radiologists identified polyps separately for both supine and prone data sets, and then manually registered corresponding pairs. The algorithm correctly matched 78% of these pairs without user input. The algorithm was also applied to the 30 highest-scoring CAD hits in the prone and supine scans and showed a success rate of 50% in automatically registering corresponding polyp pairs. Finally, we computed the average number of CAD hits that need to be manually compared in order to find the correct matches among the top 30 CAD hits. With polyp registration, the average number of comparisons was 1.78 per polyp, as opposed to 4.28 comparisons without polyp registration.« less
Deep neural network-based computer-assisted detection of cerebral aneurysms in MR angiography.
Nakao, Takahiro; Hanaoka, Shouhei; Nomura, Yukihiro; Sato, Issei; Nemoto, Mitsutaka; Miki, Soichiro; Maeda, Eriko; Yoshikawa, Takeharu; Hayashi, Naoto; Abe, Osamu
2018-04-01
The usefulness of computer-assisted detection (CAD) for detecting cerebral aneurysms has been reported; therefore, the improved performance of CAD will help to detect cerebral aneurysms. To develop a CAD system for intracranial aneurysms on unenhanced magnetic resonance angiography (MRA) images based on a deep convolutional neural network (CNN) and a maximum intensity projection (MIP) algorithm, and to demonstrate the usefulness of the system by training and evaluating it using a large dataset. Retrospective study. There were 450 cases with intracranial aneurysms. The diagnoses of brain aneurysms were made on the basis of MRA, which was performed as part of a brain screening program. Noncontrast-enhanced 3D time-of-flight (TOF) MRA on 3T MR scanners. In our CAD, we used a CNN classifier that predicts whether each voxel is inside or outside aneurysms by inputting MIP images generated from a volume of interest (VOI) around the voxel. The CNN was trained in advance using manually inputted labels. We evaluated our method using 450 cases with intracranial aneurysms, 300 of which were used for training, 50 for parameter tuning, and 100 for the final evaluation. Free-response receiver operating characteristic (FROC) analysis. Our CAD system detected 94.2% (98/104) of aneurysms with 2.9 false positives per case (FPs/case). At a sensitivity of 70%, the number of FPs/case was 0.26. We showed that the combination of a CNN and an MIP algorithm is useful for the detection of intracranial aneurysms. 4 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:948-953. © 2017 International Society for Magnetic Resonance in Medicine.
Stress-induced alteration of left ventricular eccentricity: An additional marker of multivessel CAD.
Gimelli, Alessia; Liga, Riccardo; Giorgetti, Assuero; Casagranda, Mirta; Marzullo, Paolo
2017-03-28
Abnormal left ventricular (LV) eccentricity index (EI) is a marker of adverse cardiac remodeling. However, the interaction between stress-induced alterations of EI and major cardiac parameters has not been explored. We sought to evaluate the relationship between LV EI and coronary artery disease (CAD) burden in patients submitted to myocardial perfusion imaging (MPI). Three-hundred and forty-three patients underwent MPI and coronary angiography. LV ejection fraction (EF) and EI were computed from gated stress images as measures of stress-induced functional impairment. One-hundred and thirty-six (40%), 122 (35%), and 85 (25%) patients had normal coronary arteries, single-vessel CAD, and multivessel CAD, respectively. Post-stress EI was lower in patients with multivessel CAD than in those with normal coronary arteries and single-vessel CAD (P = 0.001). This relationship was confirmed only in patients undergoing exercise stress test, where a lower post-stress EI predicted the presence of multivessel CAD (P = 0.039). Post-stress alterations of LV EI on MPI may unmask the presence of multivessel CAD.
Diercks, Deborah B; Kirk, J Douglas; Turnipseed, Samuel D; Amsterdam, Ezra A
2007-12-01
Risk of acute coronary events in patients with methamphetamine and cocaine intoxication has been described. Little is known about the need for additional evaluation in these patients who do not have evidence of myocardial infarction after the initial emergency department evaluation. We herein describe our experience with these patients in a chest pain unit (CPU) and the rate of cardiac-related chest pain in this group. Retrospective analysis of patients evaluated in our CPU from January 1, 2000 to December 16, 2004 with a history of chest pain. Patients who had a positive urine toxicologic screen for methamphetamine or cocaine were included. No patients had ECG or cardiac injury marker evidence of myocardial infarction or ischemia during the initial emergency department evaluation. A diagnosis of cardiac-related chest pain was based upon positive diagnostic testing (exercise stress testing, nuclear perfusion imaging, stress echocardiography, or coronary artery stenosis >70%). During the study period, 4568 patients were evaluated in the CPU. A total of 1690 (37%) of patients admitted to the CPU underwent urine toxicologic testing. The result of urine toxicologic test was positive for cocaine or methamphetamine in 224 (5%). In the 2871 patients who underwent diagnostic testing for coronary artery disease (CAD), 401 (14%) were found to have positive results. There was no difference in the prevalence of CAD between those with positive result for toxicology screens (26/156, 17%) and those without (375/2715, 13%, RR 1.2, 95% CI 0.8-1.7). These findings suggest a relatively high rate of CAD in patients with methamphetamine and cocaine use evaluated in a CPU.
Ji, Min-Kyung; Park, Ji-Hee; Park, Sang-Won; Yun, Kwi-Dug; Oh, Gye-Jeong; Lim, Hyun-Pil
2015-08-01
This study was to evaluate the marginal fit of two CAD-CAM anatomic contour zirconia crown systems compared to lithium disilicate glass-ceramic crowns. Shoulder and deep chamfer margin were formed on each acrylic resin tooth model of a maxillary first premolar. Two CAD-CAM systems (Prettau®Zirconia and ZENOSTAR®ZR translucent) and lithium disilicate glass ceramic (IPS e.max®press) crowns were made (n=16). Each crown was bonded to stone dies with resin cement (Rely X Unicem). Marginal gap and absolute marginal discrepancy of crowns were measured using a light microscope equipped with a digital camera (Leica DFC295) magnified by a factor of 100. Two-way analysis of variance (ANOVA) and post-hoc Tukey's HSD test were conducted to analyze the significance of crown marginal fit regarding the finish line configuration and the fabrication system. The mean marginal gap of lithium disilicate glass ceramic crowns (IPS e.max®press) was significantly lower than that of the CAD-CAM anatomic contour zirconia crown system (Prettau®Zirconia) (P<.05). Both fabrication systems and finish line configurations significantly influenced the absolute marginal discrepancy (P<.05). The lithium disilicate glass ceramic crown (IPS e.max®press) had significantly smaller marginal gap than the CAD-CAM anatomic contour zirconia crown system (Prettau®Zirconia). In terms of absolute marginal discrepancy, the CAD-CAM anatomic contour zirconia crown system (ZENOSTAR®ZR translucent) had under-extended margin, whereas the CAD-CAM anatomic contour zirconia crown system (Prettau®Zirconia) and lithium disilicate glass ceramic crowns (IPS e.max®press) had overextended margins.
Hirose, Tomohiro; Nitta, Norihisa; Shiraishi, Junji; Nagatani, Yukihiro; Takahashi, Masashi; Murata, Kiyoshi
2008-12-01
The aim of this study was to evaluate the usefulness of computer-aided diagnosis (CAD) software for the detection of lung nodules on multidetector-row computed tomography (MDCT) in terms of improvement in radiologists' diagnostic accuracy in detecting lung nodules, using jackknife free-response receiver-operating characteristic (JAFROC) analysis. Twenty-one patients (6 without and 15 with lung nodules) were selected randomly from 120 consecutive thoracic computed tomographic examinations. The gold standard for the presence or absence of nodules in the observer study was determined by consensus of two radiologists. Six expert radiologists participated in a free-response receiver operating characteristic study for the detection of lung nodules on MDCT, in which cases were interpreted first without and then with the output of CAD software. Radiologists were asked to indicate the locations of lung nodule candidates on the monitor with their confidence ratings for the presence of lung nodules. The performance of the CAD software indicated that the sensitivity in detecting lung nodules was 71.4%, with 0.95 false-positive results per case. When radiologists used the CAD software, the average sensitivity improved from 39.5% to 81.0%, with an increase in the average number of false-positive results from 0.14 to 0.89 per case. The average figure-of-merit values for the six radiologists were 0.390 without and 0.845 with the output of the CAD software, and there was a statistically significant difference (P < .0001) using the JAFROC analysis. The CAD software for the detection of lung nodules on MDCT has the potential to assist radiologists by increasing their accuracy.
Arocha, Mariana A; Basilio, Juan; Llopis, Jaume; Di Bella, Enrico; Roig, Miguel; Ardu, Stefano; Mayoral, Juan R
2014-07-01
The aim of this study was to determine, by using a spectrophotometer device, the colour stainability of two indirect CAD/CAM processed composites in comparison with two conventionally laboratory-processed composites after being immersed 4 weeks in staining solutions such as coffee, black tea and red wine, using distilled water as control group. Two indirect CAD/CAM composites (Lava Ultimate and Paradigm MZ100) and two conventionally laboratory-processed composites (SR Adoro and Premise Indirect) of shade A2 were selected (160 disc samples). Colour stainability was measured after 4 weeks of immersion in three staining solutions (black tea, coffee, red wine) and distilled water. Specimen's colour was measured each week by means of a spectrophotometer (CIE L*a*b* system). Statistical analysis was carried out performing repeated ANOVA measurements and Tukey's HSD test to evaluate differences in ΔE00 measurements between groups; the interactions among composites, staining solutions and time duration were also evaluated. All materials showed significant discoloration (p<0.01) when compared to control group. The highest ΔE00 observed was with red wine, whereas black tea showed the lowest one. Indirect laboratory-processed resin composites showed the highest colour stability compared with CAD/CAM resin blocks. CAD/CAM processed composites immersed in staining solutions showed lower colour stability when compared to conventionally laboratory-processed resin composites. The demand for CAD/CAM restorations has been increasing; however, colour stainability for such material has been insufficiently studied. Moreover, this has not been performed comparing CAD/CAM processed composites versus laboratory-processed indirect composites by immersing in staining solutions for long immersion periods. Copyright © 2014 Elsevier Ltd. All rights reserved.
Egilmez, Ferhan; Ergun, Gulfem; Cekic-Nagas, Isil; Vallittu, Pekka K; Lassila, Lippo V J
To evaluate the light transmission characteristics of different types, shades, and thicknesses of novel CAD/CAM materials and their effect on the degree of conversion (DC) of a dual-curing resin cement. Square specimens (12 × 12 mm2) of three CAD/CAM materials - GC Cerasmart, Lava Ultimate, Vita Enamic - of different thicknesses (1.00, 1.50, and 2.00 mm, n = 5 per thickness) were irradiated with an LED unit. The amount of transmitted light was quantified. Thereafter, the DC% of the dual-curing resin cement (RelyX Ultimate) was recorded after 15 min using Fourier transform infrared spectroscopy. Statistical analysis was performed using two-way ANOVA followed by the Tukey's HSD post-hoc test at a significance level of p < 0.05. Regression analysis was performed to investigate the correlation between the DC and radiant energy, and the DC and thickness. Although the type and shade of CAD/CAM material significantly affect transmitted light irradiation (p < 0.0001), degrees of conversion are similar when the CAD/CAM material or material shade were taken into consideration (p > 0.05). Conversely, material thickness significantly affected light transmission (p < 0.0001) and DC (p < 0.0001). Multiple effects of material, shade, and thickness did not significantly affect the evaluated parameters (p = 0.638 for light irradiation; p = 0.637 for DC). Linear regression analysis showed a correlation between delivered energy and DC% results of the Vita Enamic (R² = 0.4169, p < 0.0001). Reduced light transmission in 2-mm-thick specimens of all CAD/CAM materials indicates that proper curing of the cement beneath CAD/CAM materials should be ensured.
Miyauchi, Katsumi; Kimura, Takeshi; Shimokawa, Hiroaki; Daida, Hiroyuki; Iimuro, Satoshi; Iwata, Hiroshi; Ozaki, Yukio; Sakuma, Ichiro; Nakagawa, Yoshihisa; Hibi, Kiyoshi; Hiro, Takafumi; Fukumoto, Yoshihiro; Hokimoto, Seiji; Ohashi, Yasuo; Ohtsu, Hiroshi; Saito, Yasushi; Matsuzaki, Masunori; Nagai, Ryozo
2018-03-30
Large-scale clinical trials in patients in Western countries with coronary artery disease (CAD) have found that aggressive lipid-lowering therapy using high-dose statins reduces cardiovascular (CV) events further than low-dose statins. However, such evidence has not yet been fully established in Asian populations, including in Japan. The Randomized Evaluation of Aggressive or Moderate Lipid-Lowering Therapy with Pitavastatin in Coronary Artery Disease (REAL-CAD) study addresses whether intensification of statin therapy improves clinical outcomes in Japanese patients with CAD.REAL-CAD is a prospective, multicenter, randomized, open-label, blinded-endpoint, physician-initiated phase 4 trial in Japan. The study will recruit up to 12,600 patients with stable CAD. Patients are assigned to receive either pitavastatin 1 mg/day or pitavastatin 4 mg/day. LDL-C levels are expected to reach approximate mean values of 100 mg/dL in the low-dose pitavastatin group and 80 mg/dL in the high-dose group. The primary endpoint is the time to occurrence of a major CV event, including CV death, non-fatal myocardial infarction, non-fatal ischemic stroke, and unstable angina requiring emergency hospitalization during an average of 5 years. The large number of patients and the long follow-up period in the REAL-CAD study should ensure that there is adequate power to definitively determine if reducing LDL-C levels to approximately 80 mg/dL by high-dose statin can provide additional clinical benefit.After the study is completed, we will have categorical evidence on the optimal statin dose and target LDL-C level for secondary prevention in Japanese patients.
On the Use of CAD-Native Predicates and Geometry in Surface Meshing
NASA Technical Reports Server (NTRS)
Aftosmis, M. J.
1999-01-01
Several paradigms for accessing CAD geometry during surface meshing for CFD are discussed. File translation, inconsistent geometry engines and non-native point construction are all identified as sources of non-robustness. The paper argues in favor of accessing CAD parts and assemblies in their native format, without translation, and for the use of CAD-native predicates and constructors in surface mesh generation. The discussion also emphasizes the importance of examining the computational requirements for exact evaluation of triangulation predicates during surface meshing. The native approach is demonstrated through an algorithm for the generation of closed manifold surface triangulations from CAD geometry. CAD parts and assemblies are used in their native format, and a part's native geometry engine is accessed through a modeler-independent application programming interface (API). In seeking a robust and fully automated procedure, the algorithm is based on a new physical space manifold triangulation technique specially developed to avoid robustness issues associated with poorly conditioned mappings. In addition, this approach avoids the usual ambiguities associated with floating-point predicate evaluation on constructed coordinate geometry in a mapped space. The technique is incremental, so that each new site improves the triangulation by some well defined quality measure. The algorithm terminates after achieving a prespecified measure of mesh quality and produces a triangulation such that no angle is less than a given angle bound, a or greater than pi - 2alpha. This result also sets bounds on the maximum vertex degree, triangle aspect-ratio and maximum stretching rate for the triangulation. In addition to the output triangulations for a variety of CAD parts, the discussion presents related theoretical results which assert the existence of such an angle bound, and demonstrate that maximum bounds of between 25 deg and 30 deg may be achieved in practice.
Sagsoz, N Polat; Yanıkoglu, N
2018-04-01
The purpose of this study was to evaluate the fracture resistance of monolithic computer-aided design/computer-aided manufacturing (CAD/CAM) crowns that are prepared with different cement thickness. For this investigation, a human maxillary premolar tooth was selected. Master model preparation was performed with a demand bur under water spray. Master die was taken to fabricate 105 epoxy resin replicas. The crowns were milled using a CEREC 4 CAD/CAM system (Software Version, 4.2.0.57192). CAD/CAM crowns were made using resin nanoceramic, feldspathic glass ceramic, lithium disilicate, and leucite-reinforced ceramics. Each group was subdivided into three groups in accordance with three different cement thicknesses (30, 90, and 150 μm). Crowns milled out. Then RelyX ™ U200 was used as a luting agent to bond the crowns to the prepared samples. After one hour cementations, the specimens were stored in water bath at 37°C for 1 week before testing. Seven unprepared and unrestored teeth were kept and tested as a control group. A universal test machine was used to assume the fracture resistance of all specimens. The compressive load (N) that caused fracture was recorded for each specimen. Fracture resistance data were statistically analyzed by one-way ANOVA and two-factor interaction modeling test (α = 0.001). There are statistically significant differences between fracture resistances of CAD/CAM monolithic crown materials (P < 0.001). It is seen that cement thickness is not statistically significant for fracture resistance of CAD/CAM monolithic crowns (P > 0.001). CAD/CAM monolithic crown materials affected fracture resistance. Cement thickness (30, 90, and 150 μm) was not effective on fracture resistance of CAD/CAM monolithic crowns.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Womersley, J.; DiGiacomo, N.; Killian, K.
1990-04-01
Detailed detector design has traditionally been divided between engineering optimization for structural integrity and subsequent physicist evaluation. The availability of CAD systems for engineering design enables the tasks to be integrated by providing tools for particle simulation within the CAD system. We believe this will speed up detector design and avoid problems due to the late discovery of shortcomings in the detector. This could occur because of the slowness of traditional verification techniques (such as detailed simulation with GEANT). One such new particle simulation tool is described. It is being used with the I-DEAS CAD package for SSC detector designmore » at Martin-Marietta Astronautics and is to be released through the SSC Laboratory.« less
NASA Technical Reports Server (NTRS)
Pinckney, John
2010-01-01
With the advent of high speed computing Monte Carlo ray tracing techniques has become the preferred method for evaluating spacecraft orbital heats. Monte Carlo has its greatest advantage where there are many interacting surfaces. However Monte Carlo programs are specialized programs that suffer from some inaccuracy, long calculation times and high purchase cost. A general orbital heating integral is presented here that is accurate, fast and runs on MathCad, a generally available engineering mathematics program. The integral is easy to read, understand and alter. The integral can be applied to unshaded primitive surfaces at any orientation. The method is limited to direct heating calculations. This integral formulation can be used for quick orbit evaluations and spot checking Monte Carlo results.
Shimizu, Sakura; Shinya, Akikazu; Kuroda, Soichi; Gomi, Harunori
2017-07-26
The accuracy of prostheses affects clinical success and is, in turn, affected by the accuracy of the scanner and CAD programs. Thus, their accuracy is important. The first aim of this study was to evaluate the accuracy of an intraoral scanner with active triangulation (Cerec Omnicam), an intraoral scanner with a confocal laser (3Shape Trios), and an extraoral scanner with active triangulation (D810). The second aim of this study was to compare the accuracy of the digital crowns designed with two different scanner/CAD combinations. The accuracy of the intraoral scanners and extraoral scanner was clinically acceptable. Marginal and internal fit of the digital crowns fabricated using the intraoral scanner and CAD programs were inferior to those fabricated using the extraoral scanner and CAD programs.
Bunevicius, Adomas; Staniute, Margarita; Brozaitiene, Julija; Pommer, Antoinette M; Pop, Victor J M; Montgomery, Stuart A; Bunevicius, Robertas
2012-09-01
The aim of this study was to evaluate, in patients with coronary artery disease (CAD), factor structure and psychometric properties of the Montgomery Åsberg Depression Rating Scale (MADRS) to identify patients with current major depressive episode (MDE). The construct validity of the MADRS against self-rating scales was also evaluated. Consecutive 522 CAD patients at admission to the cardiac rehabilitation program were interviewed for the severity of depressive symptoms using the MADRS and for current MDE using the structured MINI International Neuropsychiatric Interview. Also, all patients completed the Hospital Anxiety and Depression Scale and the Beck Depression Inventory-II. The MADRS had one-factor structure and high internal consistency (Cronbach's coefficient α=0.82). Confirmative factor analysis indicated an adequate fit: comparative fit index=0.95, normed fit index=0.91, and root mean square error of approximation=0.07. At a cut-off value of 10 or higher, the MADRS had good psychometric properties for the identification of current MDE (positive predictive value=42%, with sensitivity=88% and specificity=85%). There was also a moderate to strong correlation of MADRS scores with scores on self-rating depression scales. In sum, in CAD patients undergoing rehabilitation, the MADRS is a unidimensional instrument with high internal consistency and can be used for the identification of depressed CAD patients. The association between MADRS and self-rating depression scores is moderate to strong. © 2012 Wolters Kluwer Health | Lippincott Williams & Wilkins.
Prototypes for Content-Based Image Retrieval in Clinical Practice
Depeursinge, Adrien; Fischer, Benedikt; Müller, Henning; Deserno, Thomas M
2011-01-01
Content-based image retrieval (CBIR) has been proposed as key technology for computer-aided diagnostics (CAD). This paper reviews the state of the art and future challenges in CBIR for CAD applied to clinical practice. We define applicability to clinical practice by having recently demonstrated the CBIR system on one of the CAD demonstration workshops held at international conferences, such as SPIE Medical Imaging, CARS, SIIM, RSNA, and IEEE ISBI. From 2009 to 2011, the programs of CADdemo@CARS and the CAD Demonstration Workshop at SPIE Medical Imaging were sought for the key word “retrieval” in the title. The systems identified were analyzed and compared according to the hierarchy of gaps for CBIR systems. In total, 70 software demonstrations were analyzed. 5 systems were identified meeting the criterions. The fields of application are (i) bone age assessment, (ii) bone fractures, (iii) interstitial lung diseases, and (iv) mammography. Bridging the particular gaps of semantics, feature extraction, feature structure, and evaluation have been addressed most frequently. In specific application domains, CBIR technology is available for clinical practice. While system development has mainly focused on bridging content and feature gaps, performance and usability have become increasingly important. The evaluation must be based on a larger set of reference data, and workflow integration must be achieved before CBIR-CAD is really established in clinical practice. PMID:21892374
Bone age assessment by content-based image retrieval and case-based reasoning
NASA Astrophysics Data System (ADS)
Fischer, Benedikt; Welter, Petra; Grouls, Christoph; Günther, Rolf W.; Deserno, Thomas M.
2011-03-01
Skeletal maturity is assessed visually by comparing hand radiographs to a standardized reference image atlas. Most common are the methods by Greulich & Pyle and Tanner & Whitehouse. For computer-aided diagnosis (CAD), local image regions of interest (ROI) such as the epiphysis or the carpal areas are extracted and evaluated. Heuristic approaches trying to automatically extract, measure and classify bones and distances between bones suffer from the high variability of biological material and the differences in bone development resulting from age, gender and ethnic origin. Content-based image retrieval (CBIR) provides a robust solution without delineating and measuring bones. In this work, epiphyseal ROIs (eROIS) of a hand radiograph are compared to previous cases with known age, mimicking a human observer. Leaving-one-out experiments are conducted on 1,102 left hand radiographs and 15,428 metacarpal and phalangeal eROIs from the publicly available USC hand atlas. The similarity of the eROIs is assessed by a combination of cross-correlation, image distortion model, and Tamura texture features, yielding a mean error rate of 0.97 years and a variance of below 0.63 years. Furthermore, we introduce a publicly available online-demonstration system, where queries on the USC dataset as well as on uploaded radiographs are performed for instant CAD. In future, we plan to evaluate physician with CBIR-CAD against physician without CBIR-CAD rather than physician vs. CBIR-CAD.
NASA Astrophysics Data System (ADS)
Mazzetti, S.; Giannini, V.; Russo, F.; Regge, D.
2018-05-01
Computer-aided diagnosis (CAD) systems are increasingly being used in clinical settings to report multi-parametric magnetic resonance imaging (mp-MRI) of the prostate. Usually, CAD systems automatically highlight cancer-suspicious regions to the radiologist, reducing reader variability and interpretation errors. Nevertheless, implementing this software requires the selection of which mp-MRI parameters can best discriminate between malignant and non-malignant regions. To exploit functional information, some parameters are derived from dynamic contrast-enhanced (DCE) acquisitions. In particular, much CAD software employs pharmacokinetic features, such as K trans and k ep, derived from the Tofts model, to estimate a likelihood map of malignancy. However, non-pharmacokinetic models can be also used to describe DCE-MRI curves, without any requirement for prior knowledge or measurement of the arterial input function, which could potentially lead to large errors in parameter estimation. In this work, we implemented an empirical function derived from the phenomenological universalities (PUN) class to fit DCE-MRI. The parameters of the PUN model are used in combination with T2-weighted and diffusion-weighted acquisitions to feed a support vector machine classifier to produce a voxel-wise malignancy likelihood map of the prostate. The results were all compared to those for a CAD system based on Tofts pharmacokinetic features to describe DCE-MRI curves, using different quality aspects of image segmentation, while also evaluating the number and size of false positive (FP) candidate regions. This study included 61 patients with 70 biopsy-proven prostate cancers (PCa). The metrics used to evaluate segmentation quality between the two CAD systems were not statistically different, although the PUN-based CAD reported a lower number of FP, with reduced size compared to the Tofts-based CAD. In conclusion, the CAD software based on PUN parameters is a feasible means with which to detect PCa, without affecting segmentation quality, and hence it could be successfully applied in clinical settings, improving the automated diagnosis process and reducing computational complexity.
Maroules, Christopher D; Hamilton-Craig, Christian; Branch, Kelley; Lee, James; Cury, Roberto C; Maurovich-Horvat, Pál; Rubinshtein, Ronen; Thomas, Dustin; Williams, Michelle; Guo, Yanshu; Cury, Ricardo C
The Coronary Artery Disease Reporting and Data System (CAD-RADS) provides a lexicon and standardized reporting system for coronary CT angiography. To evaluate inter-observer agreement of the CAD-RADS among an panel of early career and expert readers. Four early career and four expert cardiac imaging readers prospectively and independently evaluated 50 coronary CT angiography cases using the CAD-RADS lexicon. All readers assessed image quality using a five-point Likert scale, with mean Likert score ≥4 designating high image quality, and <4 designating moderate/low image quality. All readers were blinded to medical history and invasive coronary angiography findings. Inter-observer agreement for CAD-RADS assessment categories and modifiers were assessed using intra-class correlation (ICC) and Fleiss' Kappa (κ).The impact of reader experience and image quality on inter-observer agreement was also examined. Inter-observer agreement for CAD-RADS assessment categories was excellent (ICC 0.958, 95% CI 0.938-0.974, p < 0.0001). Agreement among expert readers (ICC 0.925, 95% CI 0.884-0.954) was marginally stronger than for early career readers (ICC 0.904, 95% CI 0.852-0.941), both p < 0.0001. High image quality was associated with stronger agreement than moderate image quality (ICC 0.944, 95% CI 0.886-0.974 vs. ICC 0.887, 95% CI 0.775-0.95, both p < 0.0001). While excellent inter-observer agreement was observed for modifiers S (stent) and G (bypass graft) (both κ = 1.0), only fair agreement (κ = 0.40) was observed for modifier V (high risk plaque). Inter-observer reproducibility of CAD-RADS assessment categories and modifiers is excellent, except for high-risk plaque (modifier V) which demonstrates fair agreement. These results suggest CAD-RADS is feasible for clinical implementation. Copyright © 2017. Published by Elsevier Inc.
Mossmann, Márcio; Wainstein, Marco V; Gonçalves, Sandro C; Wainstein, Rodrigo V; Gravina, Gabriela L; Sangalli, Marlei; Veadrigo, Francine; Matte, Roselene; Reich, Rejane; Costa, Fernanda G; Bertoluci, Marcello C
2015-01-01
Insulin resistance is a major component of metabolic syndrome, type 2 Diabetes Mellitus (T2DM) and coronary artery disease (CAD). Although important in T2DM, its role as a predictor of CAD in non-diabetic patients is less studied. In the present study, we aimed to evaluate the association of HOMA-IR with significant CAD, determined by coronary angiography in non-obese, non-T2DM patients. We also evaluate the association between 3 oral glucose tolerance test (OGTT) based insulin sensitivity indexes (Matsuda, STUMVOLL-ISI and OGIS) and CAD. We conducted a cross-sectional study with 54 non-obese, non-diabetic individuals referred for coronary angiography due to suspected CAD. CAD was classified as the "anatomic burden score" corresponding to any stenosis equal or larger than 50 % in diameter on the coronary distribution. Patients without lesions were included in No-CAD group. Patients with at least 1 lesion were included in the CAD group. A 75 g oral glucose tolerance test (OGTT) with measurements of plasma glucose and serum insulin at 0, 30, 60, 90 and 120 min was obtained to calculate insulin sensitivity parameters. HOMA-IR results were ranked and patients were also categorized into insulin resistant (IR) or non-insulin resistant (NIR) if they were respectively above or below the 75th percentile (HOMA-IR > 4.21). The insulin sensitivity tests results were also divided into IR and NIR, respectively below and above each 25th percentile. Chi square was used to study association. Poisson Regression Model was used to compare prevalence ratios between categorized CAD and IR groups. Fifty-four patients were included in the study. There were 26 patients (48 %) with significant CAD. The presence of clinically significant CAD was significant associated with HOMA-IR above p75 (Chi square 4.103, p = 0.0428) and 71 % of patients with HOMA-IR above p75 had significant CAD. Subjects with CAD had increased prevalence ratio of HOMA-IR above p75 compared to subjects without CAD (PR 1.78; 95 % CI 1.079-2.95; p = 0.024). Matsuda index, Stumvoll-ISI and OGIS index were not associated with significant CAD. We concluded that, in patients without diabetes or obesity, in whom a coronary angiography study is indicated, a single determination of HOMA-IR above 4.21 indicates increased risk for clinical significant coronary disease. The same association was not seen with insulin sensitivity indexes such as Matsuda, Stunvoll-ISI or OGIS. These findings support the need for further longitudinal research using HOMA-IR as a predictor of cardiovascular disease.
Color stability of CAD/CAM Zirconia ceramics following exposure to acidic and staining drinks
Colombo, Marco; Cavallo, Marco; Miegge, Matteo; Dagna, Alberto; Beltrami, Riccardo; Chiesa, Marco
2017-01-01
Background The aim of this in vitro study was to evaluate the color stability of CAD/CAM Zirconia ceramics following exposure to acidic drink (Coca Cola) and after exposure to staining solution (coffee). Material and Methods All the samples were immersed in different staining solutions over a 28-day test period. A colorimetric evaluation according to the CIE L*a*b* system was performed by a blind trained operator at 7, 14, 21, 28 days of the staining process. Shapiro Wilk test and Kruskal-Wallis ANOVA were applied to assess significant differences among restorative materials. Paired t-test was applied to test which CIE L*a*b* parameters significantly changed after immersion in staining solutions. Results One week immersion in acidic drink did not cause a perceivable discoloration for all restorative materials (ΔE < 3.3). Subsequent immersion in coffee affected color stability of all Zirconia samples, even if Kruskal-Wallis ANOVA found significant differences among the various restorative materials. Conclusions The ∆Es of CAD/CAM Zirconia ceramics after immersion in coffee varied among the products, but color integrity is not affected by contact with acidic drinks. Key words:CAD/CAM restorative materials, CIE Lab, Zirconia ceramics. PMID:29302281
Color stability of CAD/CAM Zirconia ceramics following exposure to acidic and staining drinks.
Colombo, Marco; Cavallo, Marco; Miegge, Matteo; Dagna, Alberto; Beltrami, Riccardo; Chiesa, Marco; Poggio, Claudio
2017-11-01
The aim of this in vitro study was to evaluate the color stability of CAD/CAM Zirconia ceramics following exposure to acidic drink (Coca Cola) and after exposure to staining solution (coffee). All the samples were immersed in different staining solutions over a 28-day test period. A colorimetric evaluation according to the CIE L*a*b* system was performed by a blind trained operator at 7, 14, 21, 28 days of the staining process. Shapiro Wilk test and Kruskal-Wallis ANOVA were applied to assess significant differences among restorative materials. Paired t-test was applied to test which CIE L*a*b* parameters significantly changed after immersion in staining solutions. One week immersion in acidic drink did not cause a perceivable discoloration for all restorative materials (ΔE < 3.3). Subsequent immersion in coffee affected color stability of all Zirconia samples, even if Kruskal-Wallis ANOVA found significant differences among the various restorative materials. The ∆Es of CAD/CAM Zirconia ceramics after immersion in coffee varied among the products, but color integrity is not affected by contact with acidic drinks. Key words: CAD/CAM restorative materials, CIE Lab, Zirconia ceramics.
Sun, Dandan; Sun, Liping; Xu, Qian; Gong, Yuehua; Wang, Honghu; Yang, Jun; Yuan, Yuan
2016-03-04
The toll-like receptor 4 (TLR4)-myeloid differentiation factor 88 (MyD88)-dependent signaling pathway plays a role in the initiation and progression of coronary artery disease (CAD). We investigated SNP-SNP interactions between the TLR4 and MyD88 genes in CAD susceptibility and assessed whether the effects of such interactions were modified by confounding risk factors (hyperglycemia, hyperlipidemia and Helicobacter pylori (H. pylori) infection). Participants with CAD (n = 424) and controls (n = 424) without CAD were enrolled. Polymerase chain restriction-restriction fragment length polymorphism was performed on genomic DNA to detect polymorphisms in TLR4 (rs10116253, rs10983755, and rs11536889) and MyD88 (rs7744). H. pylori infections were evaluated by enzyme-linked immunosorbent assays, and the cardiovascular risk factors for each subject were evaluated clinically. The significant interaction between TLR4 rs11536889 and MyD88 rs7744 was associated with an increased CAD risk (p value for interaction = 0.024). In conditions of hyperglycemia, the interaction effect was strengthened between TLR4 rs11536889 and MyD88 rs7744 (p value for interaction = 0.004). In hyperlipidemic participants, the interaction strength was also enhanced for TLR4 rs11536889 and MyD88 rs7744 (p value for interaction = 0.006). Thus, the novel interaction between TLR4 rs11536889 and MyD88 rs7744 was related with an increased risk of CAD, that could be strengthened by the presence of hyperglycemia or hyperlipidemia.
Awad, Mohamed Moustafa; Alqahtani, H; Al-Mudahi, A; Murayshed, M S; Alrahlah, A; Bhandi, Shilpa H
2017-07-01
To review the adhesive bonding to different computer-aided design/computer-aided manufacturing (CAD/CAM) esthetic restorative materials. The use of CAD/CAM esthetic restorative materials has gained popularity in recent years. Several CAD/ CAM esthetic restorative materials are commercially available. Adhesive bonding is a major determinant of success of CAD/ CAM restorations. Review result: An account of the currently available bonding strategies are discussed with their rationale in various CAD/ CAM materials. Different surface treatment methods as well as adhesion promoters can be used to achieve reliable bonding of CAD/CAM restorative materials. Selection of bonding strategy to such material is determined based on its composition. Further evidence is required to evaluate the effect of new surface treatment methods, such as nonthermal atmospheric plasma and self-etching ceramic primer on bonding to different dental ceramics. An understanding of the currently available bonding strategies to CA/CAM materials can help the clinician to select the most indicated system for each category of materials.
Lutfi, Mohamed Faisal
2017-01-01
Anxiety and cardiac autonomic modulations (CAM) were thoroughly investigated in coronary artery disease (CAD) and cardiac syndrome X (CSX) patients worldwide, but not among Sudanese with similar pathology. To compare levels of anxiety and CAM between Sudanese patients with CSX and CAD. Anxiety was evaluated in 51 CAD and 26 CSX patients using Taylor Manifest anxiety score (TMAS) questionnaire while heart rate variability derived indices were used to assess CAM, namely natural logarithm of low frequency (LnLF), high frequency (LnHF) and LF/HF ratio (LnLF/HF). Low anxiety levels were achieved by 6 (23.1%) and 9 (17.6%) patients with CSX and CAD respectively. High anxiety level was achieved by only one (3.8%) patient, who was suffering from CSX. TMAS was significantly higher in CSX (31.27 (21.97)) compared to CAD (21.86 (12.97), P = 0.021). However, abnormally increased anxiety was not associated with higher risk of CSX. LnLF, LnHF and LnLF/HF were comparable in CAD and CSX patients. CSX and CAD patients showed comparable CAM. Although anxiety levels were higher in CSX compared to CAD, TMAS ≥ 35 failed to show significant association with CSX.
Lorenzen, Nina Dyrberg; Stilling, Maiken; Jakobsen, Stig Storgaard; Gustafson, Klas; Søballe, Kjeld; Baad-Hansen, Thomas
2013-11-01
The stability of implants is vital to ensure a long-term survival. RSA determines micro-motions of implants as a predictor of early implant failure. RSA can be performed as a marker- or model-based analysis. So far, CAD and RE model-based RSA have not been validated for use in hip resurfacing arthroplasty (HRA). A phantom study determined the precision of marker-based and CAD and RE model-based RSA on a HRA implant. In a clinical study, 19 patients were followed with stereoradiographs until 5 years after surgery. Analysis of double-examination migration results determined the clinical precision of marker-based and CAD model-based RSA, and at the 5-year follow-up, results of the total translation (TT) and the total rotation (TR) for marker- and CAD model-based RSA were compared. The phantom study showed that comparison of the precision (SDdiff) in marker-based RSA analysis was more precise than model-based RSA analysis in TT (p CAD < 0.001; p RE = 0.04) and TR (p CAD = 0.01; p RE < 0.001). The clinical precision (double examination in 8 patients) comparing the precision SDdiff was better evaluating the TT using the marker-based RSA analysis (p = 0.002), but showed no difference between the marker- and CAD model-based RSA analysis regarding the TR (p = 0.91). Comparing the mean signed values regarding the TT and the TR at the 5-year follow-up in 13 patients, the TT was lower (p = 0.03) and the TR higher (p = 0.04) in the marker-based RSA compared to CAD model-based RSA. The precision of marker-based RSA was significantly better than model-based RSA. However, problems with occluded markers lead to exclusion of many patients which was not a problem with model-based RSA. HRA were stable at the 5-year follow-up. The detection limit was 0.2 mm TT and 1° TR for marker-based and 0.5 mm TT and 1° TR for CAD model-based RSA for HRA.
Ribeiro, Isabella Lima Arrais; Campos, Fernanda; Sousa, Rafael Santiago; Alves, Maria Luiza Lima; Rodrigues, Dalton Matos; Souza, Rodrigo Othavio Assuncão; Bottino, Marco Antonio
2015-01-01
Discrepancies at the abutment/crown interface can affect the longevity of zirconia restorations. The aim was to evaluate the marginal and internal discrepancies (MD and ID) of zirconia copings manufactured by two milling systems with different finish lines. Three aluminum-master-dies (h = 5.5 mm; Ψ =7.5 mm; 6), with different finish lines (large chamfer [LC]; tilted chamfer [TC]; rounded shoulder [RS]) were fabricated. Twenty impressions were made from each master die and poured. Sixty zirconia copings were manufactured and divided according to the factors "finish line" and "milling system" (n = 10): CAD LC = Computer-aided design/computer-aided manufacturing (CAD/CAM) + LC; CAD TC = CAD/CAM + TC; CAD RS = CAD/CAM + RS; MAD LC = manually aided design/manually aided manufacturing (MAD/MAM) + LC; MAD TC = MAD/MAM + TC; and MAD RS = MAD/MAM + RS. For MD analysis, each coping was fixed, and the distance between the external edges of the coping and the edge of the cervical preparation was measured (50 points). Using the same copings, the ID of each coping was evaluated, by the replica technique, at 12 points equally distributed among the regions (n = 10): Ray (R), axial (A), and occlusal (Occl). The measurements were performed by optical microscopy (Χ250). The data (μm) were subjected to parametric and non-parametric statistical analyses. For the MAD/MAM system, the "finish line" (P = 0.0001) affected significantly the MD median values (μm): LC = 251.80 a , RS = 68.40 a and TC = 8.10 b (Dunn's test). For the CAD/CAM system, the median MD values (μm) were not affected by the factor "finish line" (P = 0.4037): LC = 0.82 a , RS = 0.52 a , and TC = 0.89 a . For the ID, it was observed interaction between the finish line types and the region (P = 0.0001) and between region and milling system (P = 0.0031) (RM-ANOVA). The CAD/CAM system presented lower MD values, regardless the finish line. However, the MAD/MAM system showed ID values smaller than those of CAD/CAM.
Mously, Hisham A; Finkelman, Matthew; Zandparsa, Roya; Hirayama, Hiroshi
2014-08-01
The accuracy of chairside computer-aided design and computer-aided manufacturing (CAD/CAM) restorations is questionable, and the effect of the die spacer settings is not well stated in the literature. The purpose of the study was to evaluate the marginal and internal adaptation of E4D crowns fabricated with different spacer thicknesses and to compare these crowns with those fabricated with the heat-press technique. The E4D system was used to fabricate 30 crowns for the first 3 groups, with different spacer thickness settings: 30 μm, 60 μm, and 100 μm. In the fourth group, 10 lithium disilicate crowns were fabricated with the heat-press technique. The occlusal gap, axial gap, vertical marginal gap, and absolute marginal discrepancy were evaluated by x-ray microtomography. Statistical significance was assessed with the Kruskal-Wallis test (α=.05). For post hoc analyses, the Mann-Whitney U test was used alongside the Bonferroni correction for multiple comparisons (α=.008). Within the CAD/CAM groups, the 30-μm spacer thickness resulted in the lowest median axial gap (90.04 μm), whereas the 60-μm spacer thickness resulted in the lowest median occlusal gap (152.39 μm). The median marginal gap values of the CAD/CAM-60 group (49.35 μm) and CAD/CAM-100 group (46.65 μm) were lower than those of the CAD/CAM-30 group (55.18 μm). No significant differences among the CAD/CAM groups were observed for absolute marginal discrepancy. The heat-press group had significantly different values than those of the CAD/CAM groups. The spacer thickness and fabrication technique affected the adaptation of ceramic crowns. The heat-press group yielded the best marginal and internal crown adaptation results. The 30- or 60-μm spacer settings are recommended for the E4D CAD/CAM system. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Scaffold Library for Tissue Engineering: A Geometric Evaluation
Chantarapanich, Nattapon; Puttawibul, Puttisak; Sucharitpwatskul, Sedthawatt; Jeamwatthanachai, Pongnarin; Inglam, Samroeng; Sitthiseripratip, Kriskrai
2012-01-01
Tissue engineering scaffold is a biological substitute that aims to restore, to maintain, or to improve tissue functions. Currently available manufacturing technology, that is, additive manufacturing is essentially applied to fabricate the scaffold according to the predefined computer aided design (CAD) model. To develop scaffold CAD libraries, the polyhedrons could be used in the scaffold libraries development. In this present study, one hundred and nineteen polyhedron models were evaluated according to the established criteria. The proposed criteria included considerations on geometry, manufacturing feasibility, and mechanical strength of these polyhedrons. CAD and finite element (FE) method were employed as tools in evaluation. The result of evaluation revealed that the close-cellular scaffold included truncated octahedron, rhombicuboctahedron, and rhombitruncated cuboctahedron. In addition, the suitable polyhedrons for using as open-cellular scaffold libraries included hexahedron, truncated octahedron, truncated hexahedron, cuboctahedron, rhombicuboctahedron, and rhombitruncated cuboctahedron. However, not all pore size to beam thickness ratios (PO : BT) were good for making the open-cellular scaffold. The PO : BT ratio of each library, generating the enclosed pore inside the scaffold, was excluded to avoid the impossibility of material removal after the fabrication. The close-cellular libraries presented the constant porosity which is irrespective to the different pore sizes. The relationship between PO : BT ratio and porosity of open-cellular scaffold libraries was displayed in the form of Logistic Power function. The possibility of merging two different types of libraries to produce the composite structure was geometrically evaluated in terms of the intersection index and was mechanically evaluated by means of FE analysis to observe the stress level. The couples of polyhedrons presenting low intersection index and high stress level were excluded. Good couples for producing the reinforced scaffold were hexahedron-truncated hexahedron and cuboctahedron-rhombitruncated cuboctahedron. PMID:23056147
Wang, Yu-guang; Xing, Yan-xi; Sun, Yu-chun; Zhao, Yi-jiao; Lü, Pei-jun; Wang, Yong
2013-06-01
To evaluate clinical effects of computer aided design and computer aided manufacturing (CAD/CAM) milled zirconia crown in three aspects: aesthetic, contact wear and fracture. Sixty patients were divided into two groups.In one group, 35 full contour CAD/CAM zirconia crown were made on molars of 30 patients. The manufacturing process of zirconia crown was as follow. First, the three dimensional(3-D) data of working models, antagonist impression and check records were acquired by 3-D laser scanning Dental wings S50. Then full contour zirconia crowns, which had functional occlusal contacts with antagonistic teeth, and appropriate contact with adjacent teeth were designed with Zeno-CAD(V4.2.5.5.12919) software. ZENOSTAR Zr pure zirconia material was milled in digital controlled machine WIELAND 4030 M1.In the end, the zirconia crown were completed with the method of second sintering and polishing. After clinical try-in, the crown was cemented.In the control group, thirty gold alloy full crown were made and cemented on molars of 30 patients. According to the modified U S Public Health Service Criteria(USPHS) evaluation standard, all crowns were evaluated on the same day, at three months, half a year, one year and two years following delivery. There were three aspects we were focusing on in the evaluation: aesthetic, contact wear(restoration and antagonist), and fracture. In all the prosthesis we evaluated during the 24 months, no fracture was found. Contact wear of crowns varies according to different antagonist teeth. The zirconia crowns show privilege in aesthesis, toughness and anti-wearing.However, there is contact wear on antagonistic natural teeth. Thus it is a good choice when full zirconia crowns are indicated on two antagonistic teeth in both jaws.
Hadj Ahmed, Samia; Koubaa, Nadia; Kharroubi, Wafa; Zarrouk, Amira; Mnari, Amira; Batbout, Fethi; Gamra, Habib; Hammami, Sonia; Lizard, Gérard; Hammami, Mohamed
2017-07-01
Long and very long chain fatty acids (LCFAs and VLCFAs) may play an active role in coronary artery diseases (CAD) etiology. Our aim was to evaluate the associations between LCPUFAs (C20:4n-6; C20:5n-3 and C22:6n-3) and VLCSFAs (C22:0, C24:0; and C26:0), as well as markers of peroxisomal integrity evaluated by phytanic acid and plasmalogen-C16:0 (PL-C16:0) in addition to the markers of lipid peroxidation (malondialdehyde [MDA] and conjugated dienes [CD]) and inflammation (high sensitivity C-reactive protein [hs-CRP]) with vascular severity evaluated by Gensini score in order to determine their possible effects on CAD in Tunisian population. Lipidomic strategy based on GC/MS-SIM was used to quantify LCPUFAs, VLCSFAs, and PL-C16:0 in red blood cells of CAD patients, non-CAD patients, and controls. We observed a significant increase in phytanic acid, PL-C16:0 and VLCFAs, particularly C26:0, in CAD group compared to controls. Further our findings showed positive correlations of C26:0 with MDA and with vascular severity score (Gensini score). In addition, a significant negative correlation was shown between hs-CRP and C22:6 n-3 (r=-0.297; p=0.002) and a significant positive association was observed between hs-CRP and C20:4 n-6 levels (r=0.196; p=0.039). Our results show changes in LCPUFAs and VLCSFAs concentrations in RBC among study groups, and suggest alterations in fatty acids metabolism regulated by elongase and desaturase enzymes. The positive correlations of C20:4n-6 and the negative correlations of C22:6n-3, simultaneously with Gensini score and hs-CRP, suggest a link of both inflammation and vascular severity complication of CAD with LCPUFAs and VLCSFAs. Induction of lipid oxidation, can be one of the outcomes of LCFAs and VLCFAs accumulation in vascular tissues and, thus, playing an important role in the pathogenesis of atherosclerosis. Quantification of LCPUFAs and VLCSFAs, phytanic acid and PL-C16:0 simultaneously, would be of great value for the screening of peroxisomal disorders in vascular tissue of CAD patients. Copyright © 2017 Elsevier Inc. All rights reserved.
De Bruyn, Sara; Wouters, Edwin; Ponnet, Koen; Van Damme, Joris; Van Hal, Guido
2017-01-01
Alcohol and drug misuse among college students has been studied extensively and has been clearly identified as a public health problem. Within more general populations alcohol misuse remains one of the leading causes of disease, disability and death worldwide. Conducting research on alcohol misuse requires valid and reliable instruments to measure its consequences. One scale that is often used is the consequences scale in the Core Alcohol and Drug Survey (CADS). However, psychometric studies on the CADS are rare and the ones that do exist report varying results. This article aims to address this imbalance by examining the psychometric properties of a Dutch version of the CADS in a large sample of Flemish university and college students. The analyses are based on data collected by the inter-university project 'Head in the clouds', measuring alcohol use among students. In total, 19,253 students participated (22.1% response rate). The CADS scale was measured using 19 consequences, and participants were asked how often they had experienced these on a 6-point scale. Firstly, the factor structure of the CADS was examined. Two models from literature were compared by performing confirmatory factor analyses (CFA) and were adapted if necessary. Secondly, we assessed the composite reliability as well as the convergent, discriminant and concurrent validity. The two-factor model, identifying personal consequences (had a hangover; got nauseated or vomited; missed a class) and social consequences (got into an argument or fight; been criticized by someone I know; done something I later regretted; been hurt or injured) was indicated to be the best model, having both a good model fit and an acceptable composite reliability. In addition, construct validity was evaluated to be acceptable, with good discriminant validity, although the convergent validity of the factor measuring 'social consequences' could be improved. Concurrent validity was evaluated as good. In deciding which model best represents the data, it is crucial that not only the model fit is evaluated, but the importance of factor reliability and validity issues is also taken into account. The two-factor model, identifying personal consequences and social consequences, was concluded to be the best model. This shortened Dutch version of the CADS (CADS_D) is a useful tool to screen alcohol-related consequences among college students.
ERIC Educational Resources Information Center
Martens, Matthew P.; Brown, Natashia T.; Donovan, Brooke M.; Dude, Kim
2005-01-01
A commonly used instrument to assess negative consequences of substance use among college students is the Core Alcohol and Drug Survey (CADS; C. A. Presley, P. W. Meilman, & J. S. Leichliter, 1998; C. A. Presley, P. W. Meilman, & R. Lyerla, 1993). Results from 2 studies suggest that a subset of CADS negative consequences items can be…
Jiang, Fei-Fei; Hou, Yan; Lu, Li; Ding, Xiao-Xu; Li, Wei; Yan, Ai-Hui
2015-01-01
To evaluate the facial profiles and functional recovery of 18 patients treated by a computer-aided designed/manufactured hollow obturator prosthesis (CAD/CAM prosthesis) after total maxillectomy for malignant maxillary sinus tumor. A retrospective observational study was performed to evaluate the facial profiles and functional recovery of 18 patients with T3-4a N0 M0 maxillary sinus cancer, who were treated by total maxillectomy and simultaneous implantation of a computer-aided designed/manufactured hollow obturator prosthesis (CAD/CAM prosthesis). Follow-ups were performed 1, 3, 6, and 12 months after surgery. Facial measurements, speech intelligibility, and chewing and swallowing functions were examined. Thirteen patients converted to a permanent prosthesis 6 months after surgery. Comparisons were made between patients with and without the CAD/CAM or permanent prosthesis at various times using SPSS13.0 statistical software (SPSS Inc., Chicago, IL, USA). Speech intelligibility, facial depression, and eyeball prolapse results showed improvements with prosthesis use at 1, 3, and 6 months after surgery (p < 0.05). Swallowing function improved from level V to level II-IV with prosthesis use at 1, 3, and 6 months, and reached level I or II with permanent prosthesis use at 12 months after surgery. Simultaneous CAD/CAM prosthesis implantation recovered the facial profile, enhanced the speaking, swallowing, and chewing functions, and improved the quality of life of patients. Tumor recurrence can be detected by direct observation of the postoperative maxillary cavity. Therefore, this operation is recommended for simultaneous excision repair and functional reconstruction after total maxillectomy. This surgical treatment of maxillary sinus cancer is applied rarely in China, but it has a good effect based on our observation. Simultaneous CAD/CAM prosthesis implantation after total maxillectomy can recover the facial profile, enhance the speaking, swallowing, and chewing functions, and improve the quality of life of patients. Tumor recurrence can be detected by direct observation of the postoperative maxillary cavity. This technique avoids the need for dental implants because the bottom part of the prosthesis contains a palatal plate with dentures. © 2014 Wiley Periodicals, Inc.
Micro-CT evaluation of the marginal fit of CAD/CAM all ceramic crowns
NASA Astrophysics Data System (ADS)
Brenes, Christian
Objectives: Evaluate the marginal fit of CAD/CAM all ceramic crowns made from lithium disilicate and zirconia using two different fabrication protocols (model and model-less). METHODS: Forty anterior all ceramic restorations (20 lithium disilicate, 20 zirconia) were fabricated using a CEREC Bluecam scanner. Two different fabrication methods were used: a full digital approach and a printed model. Completed crowns were cemented and marginal gap was evaluated using Micro-CT. Each specimen was analyzed in sagittal and trans-axial orientations, allowing a 360° evaluation of the vertical and horizontal fit. RESULTS: Vertical measurements in the lingual, distal and mesial views had and estimated marginal gap from 101.9 to 133.9 microns for E-max crowns and 126.4 to 165.4 microns for zirconia. No significant differences were found between model and model-less techniques. CONCLUSION: Lithium disilicate restorations exhibited a more accurate and consistent marginal adaptation when compared to zirconia crowns. No statistically significant differences were observed when comparing model or model-less approaches.
Tanaka, Toyohiko; Nitta, Norihisa; Ohta, Shinichi; Kobayashi, Tsuyoshi; Kano, Akiko; Tsuchiya, Keiko; Murakami, Yoko; Kitahara, Sawako; Wakamiya, Makoto; Furukawa, Akira; Takahashi, Masashi; Murata, Kiyoshi
2009-12-01
A computer-aided detection (CAD) system was evaluated for its ability to detect microcalcifications and masses on images obtained with a digital phase-contrast mammography (PCM) system, a system characterised by the sharp images provided by phase contrast and by the high resolution of 25-μm-pixel mammograms. Fifty abnormal and 50 normal mammograms were collected from about 3,500 mammograms and printed on film for reading on a light box. Seven qualified radiologists participated in an observer study based on receiver operating characteristic (ROC) analysis. The average of the areas under ROC curve (AUC) values for the ROC analysis with and without CAD were 0.927 and 0.897 respectively (P = 0.015). The AUC values improved from 0.840 to 0.888 for microcalcifications (P = 0.034) and from 0.947 to 0.962 for masses (P = 0.025) respectively. The application of CAD to the PCM system is a promising approach for the detection of breast cancer in its early stages.
Bahari, Mahmoud; Savadi Oskoee, Siavash; Kimyai, Soodabeh; Pouralibaba, Firoz; Farhadi, Farrokh; Norouzi, Marouf
2014-01-01
Background and aims. The aim was to evaluate the effect of casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) on microtensile bond strength (μTBS) to carious affected dentin (CAD) using etch-and-rinse and self-etch adhesive systems. Materials and methods. The occlusal surface of 32 human molars with moderate occlusal caries was removed. Infected dentin was removed until reaching CAD and the teeth were randomly divided into two groups based on the Single Bond (SB) and Clearfil SE Bond (CSE) adhesive systems. Before composite resin bonding, each group was subdivided into three subgroups of ND, CAD and CPP-ACP-treated CAD (CAD-CPP) based on the dentin substrate. After dissecting samples to l-mm-thick cross-sections (each subgroup: n = 13), μTBS was measured at a strain rate of 0.5 mm/min. Data was analyzed using two-way ANOVA, independent samples t-test and post-hoc Tukey tests (α=0.05). Results. Bond strength of both adhesive systems to ND was significantly higher than that to CAD (P <0.001) and CAD/CPP (P < 0.001). There were no significant differences between the μTBS of SB to CAD and CAD-CPP (P > 0.05).μTBS of CSE to CAD-CPP was higher than that to CAD; however, the difference was not significant (P > 0.05). Significant differences were found between SB and CSE systems only with CAD substrate (P < 0.001). Conclusion. Regardless of the adhesive system used, surface treatment of CAD with CPP-ACP did not have a significant effect on bond strength. However, bond strength to CAD was higher with SB rather than with CSE. PMID:25346832
Alkhawam, Hassan; Nguyen, James; Sayanlar, Jason; Sogomonian, Robert; Desai, Ronak; Jolly, JoshPaul; Vyas, Neil; Syed, Umer; Homsi, Maher; Rubinstein, David
2016-01-01
In this study, we evaluated obesity as a single risk factor for coronary artery disease (CAD), along with the synergistic effect of obesity and other risk factors. A retrospective study of 7,567 patients admitted to hospital for chest pain from 2005 to 2014 and underwent cardiac catheterization. Patients were divided into two groups: obese and normal with body mass index (BMI) calculated as ≥30 kg/m(2) and <25, respectively. We assessed the modifiable and non-modifiable risk factors in obese patients and the degree of CAD. Of the 7,567 patients who underwent cardiac catheterization, 414 (5.5%) had a BMI ≥30. Of 414 obese patients, 332 (80%) had evidence of CAD. Obese patients displayed evidence of CAD at the age of 57 versus 63.3 in non-obese patients (p<0.001). Of the 332 patients with CAD and obesity, 55.4% had obstructive CAD versus 44.6% with non-obstructive CAD. In obese patients with CAD, male gender and history of smoking were major risk factors for development of obstructive CAD (p=0.001 and 0.01, respectively) while dyslipidemia was a major risk factor for non-obstructive CAD (p=0.01). Additionally, obese patients with more than one risk factor developed obstructive CAD compared to non-obstructive CAD (p=0.003). Having a BMI ≥30 appears to be a risk factor for early development of CAD. Severity of CAD in obese patients is depicted on non-modifiable and modifiable risk factors such as the male gender and smoking or greater than one risk factor, respectively.
Wu, Naqiong; Ma, Fenglian; Guo, Yuanlin; Li, Xiaoling; Liu, Jun; Qing, Ping; Xu, Ruixia; Zhu, Chenggang; Jia, Yanjun; Liu, Geng; Dong, Qian; Jiang, Lixin; Li, Jianjun
2014-01-01
Backround N-terminal pro-brain natriuretic peptide (NT-proBNP) is a reliable predictor in acute coronary artery disease (CAD). Little is known about patients with stable CAD, especially Chinese patients with CAD. The aim of the present study was to investigate the association of NT-proBNP levels with the severity of CAD in patients with normal left ventricular ejection fraction. A total of 658 consecutive patients were divided into two groups based on angiograms: CAD group (n = 484) and angiographic normal control group (n = 174). The severity of CAD was evaluated by modified Gensini score, and its relationship with NT-proBNP was analyzed. The prevalence of risk factors such as age, male gender, diabetes mellitus (DM), dyslipidemia, smoking, and family history of CAD in the CAD group were higher than that in the control group. In multivariate regression model analysis, age, gender, and DM were determinants of the presence of CAD. NT-pro BNP was found to be an independent predictor for CAD (OR:1.66 (95% CI: 1.06-2.61), P < 0.05). In a receiver operating characteristic (ROC) curve analysis, an NT-proBNP value of 641.15 pmol/L was identified as a cut-off value in the diagnosis or exclusion of CAD (area under curve (AUC) = 0.56, 95% CI: 0.51-0.61). Furthermore, NT-proBNP was positively correlated with Gensini score (r = 0.14, P < 0.001) in patients with CAD. NT-proBNP was an independent predictor for Chinese patients with CAD, suggesting that the NT-proBNP level might be associated with the presence and the severity of CAD.
Galway, Shannon; Adatia, Falisha; Grubisic, Maja; Lee, May; Daniele, Patrick; Humphries, Karin H; Sedlak, Tara L
2017-09-01
Treatment of patients with stable angina and nonobstructive coronary artery disease (CAD) has not been well characterized. We comparatively evaluated medication use in males and females with stable angina with no CAD, nonobstructive CAD, and obstructive CAD. We studied all patients ≥20 years old with stable angina undergoing coronary angiography in British Columbia (BC), Canada, from January 2008 to March 2010 (n = 7,535). No CAD, nonobstructive CAD, and obstructive CAD were defined as 0%, 1%-49%, and ≥50% luminal narrowing in any epicardial coronary artery, respectively. Medication use, 3 months before and 3 months following angiography, was obtained through BC PharmaNet for angiotensin-converting enzyme inhibitors (ACE-I), angiotensin receptor blockers (ARBs), calcium channel blockers (CCBs), beta-blockers, statins, antiplatelet agents, and prescriptions for all three ACE-I/ARBs, beta-blockers, and statins (combination therapy). Following angiography, patients with no and nonobstructive CAD had significantly lower rates of prescription use of all medications, including combination therapy, than patients with obstructive CAD (p < 0.001). Use of ACE-I/ARBs, beta-blockers, statins, and combination therapy did not differ by sex, but females had higher use of CCB in all CAD groups, and clopidogrel in nonobstructive and obstructive CAD groups, compared to males. In patients with stable angina, medication use following angiography is low in nonobstructive CAD with only 58.9% prescribed a statin and 19.4% on combination therapy at 3 months. There are no important sex differences in medication use in any CAD category post-angiography. Future studies should explore methods of improving quality of care in patients with nonobstructive CAD.
NASA Astrophysics Data System (ADS)
Wang, Yunzhi; Qiu, Yuchen; Thai, Theresa; Moore, Kathleen; Liu, Hong; Zheng, Bin
2017-03-01
Abdominal obesity is strongly associated with a number of diseases and accurately assessment of subtypes of adipose tissue volume plays a significant role in predicting disease risk, diagnosis and prognosis. The objective of this study is to develop and evaluate a new computer-aided detection (CAD) scheme based on deep learning models to automatically segment subcutaneous fat areas (SFA) and visceral (VFA) fat areas depicting on CT images. A dataset involving CT images from 40 patients were retrospectively collected and equally divided into two independent groups (i.e. training and testing group). The new CAD scheme consisted of two sequential convolutional neural networks (CNNs) namely, Selection-CNN and Segmentation-CNN. Selection-CNN was trained using 2,240 CT slices to automatically select CT slices belonging to abdomen areas and SegmentationCNN was trained using 84,000 fat-pixel patches to classify fat-pixels as belonging to SFA or VFA. Then, data from the testing group was used to evaluate the performance of the optimized CAD scheme. Comparing to manually labelled results, the classification accuracy of CT slices selection generated by Selection-CNN yielded 95.8%, while the accuracy of fat pixel segmentation using Segmentation-CNN yielded 96.8%. Therefore, this study demonstrated the feasibility of using deep learning based CAD scheme to recognize human abdominal section from CT scans and segment SFA and VFA from CT slices with high agreement compared with subjective segmentation results.
Chiba, N; Veldhuyzen Van Zanten, S J O; Escobedo, S; Grace, E; Lee, J; Sinclair, P; Barkun, A; Armstrong, D; Thomson, A B R
2004-02-01
Adult Helicobacter pylori-positive patients by 13C-urea breath test with uninvestigated dyspepsia symptoms were randomized to 1-week eradication treatment with omeprazole, metronidazole and clarithromycin (OMC) vs. omeprazole and placebo antimicrobials (OPP) in the Canadian Adult Dyspepsia Empiric Treatment-H. pylori-positive (CADET-Hp) study. To perform an economic evaluation of this 1-year study. Following blind eradication treatment, family practitioners managed patients according to their usual practices. Health resource utilization information was collected prospectively. From the mean costs of the health resources consumed and the treatment outcomes, the incremental cost-effectiveness ratios and incremental net benefits of eradication treatment vs. OPP were determined. Eradication therapy significantly improved dyspepsia symptoms (treatment success: OMC, 50%; OPP, 36%; P = 0.02). The incremental cost-effectiveness ratio of OMC vs. OPP was - 387 Canadian dollars (CAD$) per treatment success (90% CI, - CAD$1707, CAD$607), indicating a lower cost with treatment success. The incremental net benefit analysis showed that H. pylori eradication was cost-effective if the willingness-to-pay value exceeded a nominal figure of CAD$100 from a health service perspective or CAD$607 from the societal perspective. In uninvestigated patients presenting with dyspepsia at the primary care level, eradication of H. pylori in those who are H. pylori positive leads to a cost-effective improvement in dyspepsia symptoms compared with a strategy of not eradicating H. pylori in these patients.
Gao, Yulin; Jurat-Fuentes, Juan Luis; Oppert, Brenda; Fabrick, Jeffrey A; Liu, Chenxi; Gao, Jianhua; Lei, Zhongren
2011-09-01
Biopesticides containing Cry insecticidal proteins from the bacterium Bacillus thuringiensis (Bt) are effective against many lepidopteran pests, but there is a lack of Bt-based pesticides for efficient control of important coleopteran pests. Based on the reported increase in Bt toxin oligomerization by a polypeptide from the Cry3Aa receptor cadherin in Tenebrio molitor (Coleoptera: Tenebrionidae), it was hypothesized that this cadherin peptide, rTmCad1p, would enhance Cry3Aa toxicity towards coleopteran larvae. To test this hypothesis, the relative toxicity of Cry3Aa, with or without rTmCad1p, against damaging chrysomelid vegetable pests of China was evaluated. Cry3Aa toxicity was evaluated in the spotted asparagus beetle (Crioceris quatuordecimpunctata), cabbage leaf beetle (Colaphellus bowringi) and daikon leaf beetle (Phaedon brassicae). To assess the effect of rTmCad1p on Cry3Aa toxicity, neonate larvae were fed Cry3Aa toxin alone or in combination with increasing amounts of rTmCad1p. The data demonstrated that Cry3Aa toxicity was significantly increased in all three vegetable pests, resulting in as much as a 15.3-fold increase in larval mortality. The application of rTmCad1p to enhance Cry3Aa insecticidal activity has potential for use in increasing range and activity levels against coleopteran pests displaying low susceptibility to Bt-based biopesticides. Copyright © 2011 Society of Chemical Industry.
NASA Astrophysics Data System (ADS)
Qiu, Yuchen; Tan, Maxine; McMeekin, Scott; Thai, Theresa; Moore, Kathleen; Ding, Kai; Liu, Hong; Zheng, Bin
2015-03-01
The purpose of this study is to identify and apply quantitative image biomarkers for early prediction of the tumor response to the chemotherapy among the ovarian cancer patients participated in the clinical trials of testing new drugs. In the experiment, we retrospectively selected 30 cases from the patients who participated in Phase I clinical trials of new drug or drug agents for ovarian cancer treatment. Each case is composed of two sets of CT images acquired pre- and post-treatment (4-6 weeks after starting treatment). A computer-aided detection (CAD) scheme was developed to extract and analyze the quantitative image features of the metastatic tumors previously tracked by the radiologists using the standard Response Evaluation Criteria in Solid Tumors (RECIST) guideline. The CAD scheme first segmented 3-D tumor volumes from the background using a hybrid tumor segmentation scheme. Then, for each segmented tumor, CAD computed three quantitative image features including the change of tumor volume, tumor CT number (density) and density variance. The feature changes were calculated between the matched tumors tracked on the CT images acquired pre- and post-treatments. Finally, CAD predicted patient's 6-month progression-free survival (PFS) using a decision-tree based classifier. The performance of the CAD scheme was compared with the RECIST category. The result shows that the CAD scheme achieved a prediction accuracy of 76.7% (23/30 cases) with a Kappa coefficient of 0.493, which is significantly higher than the performance of RECIST prediction with a prediction accuracy and Kappa coefficient of 60% (17/30) and 0.062, respectively. This study demonstrated the feasibility of analyzing quantitative image features to improve the early predicting accuracy of the tumor response to the new testing drugs or therapeutic methods for the ovarian cancer patients.
Mazzoni, Simona; Bianchi, Alberto; Schiariti, Giulio; Badiali, Giovanni; Marchetti, Claudio
2015-04-01
The purpose of the present study was to develop a computer-aided design (CAD) and computer-aided manufacturing (CAM) technique that enabled fabrication of surgical cutting guides and titanium fixation plates that would allow the upper maxilla to be repositioned correctly without a surgical splint in orthognathic patients. Ten patients were recruited. A complete CAD-CAM workflow for orthognathic surgery has 3 steps: 1) virtual planning of the surgical treatment, 2) CAD-CAM and 3-dimensional printing of customized surgical devices (surgical cutting guide and titanium fixation plates), and 3) computer-aided surgery. Upper maxilla repositioning was performed in a waferless manner using a CAD-CAM device: the surgical cutting guide was used during surgery to pilot the osteotomy line that had been planned preoperatively at the computer and the custom-made fixation titanium plates allowed desired repositioning of the maxilla. To evaluate the reproducibility of this CAD-CAM orthognathic surgical method, the virtually planned and actually achieved positions of the upper maxilla were compared. Overlap errors using a threshold value smaller than 2 mm were evaluated, and the frequency of such errors was used as a measurement of accuracy. By this definition, the accuracy was 100% in 7 patients (range in all patients, 62 to 100%; median, 92.7%). These results tend to confirm that the use of CAD-CAM cutting guides and customized titanium plates for upper maxilla repositioning represents a promising method for the accurate reproduction of preoperative virtual planning without the use of surgical splints. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Saely, Christoph H; Leiherer, Andreas; Muendlein, Axel; Vonbank, Alexander; Rein, Philipp; Geiger, Kathrin; Malin, Cornelia; Drexel, Heinz
2016-01-01
No prospective data on the power of the adipocytokine omentin to predict cardiovascular events are available. We aimed at investigating i) the association of plasma omentin with cardiometabolic risk markers, ii) its association with angiographically determined coronary atherosclerosis, and iii) its power to predict cardiovascular events. We measured plasma omentin in 295 patients undergoing coronary angiography for the evaluation of established or suspected stable coronary artery disease (CAD), of whom 161 had significant CAD with coronary artery stenoses ≥50% and 134 did not have significant CAD. Over 3.5 years, 17.6% of our patients suffered cardiovascular events, corresponding to an annual event rate of 5.0%. At baseline, plasma omentin was not significantly associated with metabolic syndrome stigmata and did not differ significantly between patients with and subjects without significant CAD (17.2 ± 13.6 ng/ml vs. 17.5 ± 15.1 ng/ml; p = 0.783). Prospectively, however, cardiovascular event risk significantly increased over tertiles of omentin (12.1%, 13.8%, and 29.5%, for tertiles 1 through 3; ptrend = 0.003), and omentin as a continuous variable significantly predicted cardiovascular events after adjustment for age, gender, BMI, diabetes, hypertension, LDL cholesterol, HDL cholesterol, and smoking (standardized adjusted hazard ratio (HR) 1.41 [95% CI 1.16-1.72]; p < 0.001), as well as after additional adjustment for the presence and extent of significant CAD at baseline (HR 1.59 [95% CI 1.29-1.97, p < 0.001). From this first prospective evaluation of the cardiovascular risk associated with omentin we conclude that elevated plasma omentin significantly predicts cardiovascular events independently from the presence and extent of angiographically determined baseline CAD. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Optical properties of CAD-CAM ceramic systems.
Della Bona, Alvaro; Nogueira, Audrea D; Pecho, Oscar E
2014-09-01
To evaluate the direct transmittance (T%), translucency, opacity and opalescence of CAD-CAM ceramic systems and the correlation between the translucency parameter (TP) and the contrast ratio (CR). Specimens of shades A1, A2 and A3 (n=5) were fabricated from CAD-CAM ceramic blocks (IPS e.max(®) CAD HT and LT, IPS Empress(®) CAD HT and LT, Paradigm™ C, and VITABLOCS(®) Mark II) and polished to 1.0±0.01mm in thickness. A spectrophotometer (Lambda 20) was used to measure T% on the wavelength range of 400-780nm. Another spectrophotometer (VITA Easyshade(®) Advance) was used to measure the CIE L(*)a(*)b(*) coordinates and the reflectance value (Y) of samples on white and black backgrounds. TP, CR and the opalescence parameter (OP) were calculated. Data were statistically analysed using VAF (variance accounting for) coefficient with Cauchy-Schwarz inequality, one-way ANOVA, Tukey's test, Bonferroni correction and Pearson's correlation. T% of some ceramic systems is dependent on the wavelength. The spectral behaviour showed a slight and constant increase in T% up to approximately 550nm, then some ceramics changed the behaviour as the wavelength gets longer. TP and CR values ranged, respectively, from 16.79 to 21.69 and from 0.52 to 0.64 (r(2)=-0.97). OP values ranged from 3.01 to 7.64. The microstructure of CAD-CAM ceramic systems influenced the optical properties. TP and CR showed a strong correlation for all ceramic systems evaluated. Yet, all ceramics showed some degree of light transmittance. In addition to shade, this study showed that other optical properties influence on the natural appearance of dental ceramics. Copyright © 2014 Elsevier Ltd. All rights reserved.
Tan, Maxine; Aghaei, Faranak; Wang, Yunzhi; Zheng, Bin
2017-01-01
The purpose of this study is to evaluate a new method to improve performance of computer-aided detection (CAD) schemes of screening mammograms with two approaches. In the first approach, we developed a new case based CAD scheme using a set of optimally selected global mammographic density, texture, spiculation, and structural similarity features computed from all four full-field digital mammography (FFDM) images of the craniocaudal (CC) and mediolateral oblique (MLO) views by using a modified fast and accurate sequential floating forward selection feature selection algorithm. Selected features were then applied to a “scoring fusion” artificial neural network (ANN) classification scheme to produce a final case based risk score. In the second approach, we combined the case based risk score with the conventional lesion based scores of a conventional lesion based CAD scheme using a new adaptive cueing method that is integrated with the case based risk scores. We evaluated our methods using a ten-fold cross-validation scheme on 924 cases (476 cancer and 448 recalled or negative), whereby each case had all four images from the CC and MLO views. The area under the receiver operating characteristic curve was AUC = 0.793±0.015 and the odds ratio monotonically increased from 1 to 37.21 as CAD-generated case based detection scores increased. Using the new adaptive cueing method, the region based and case based sensitivities of the conventional CAD scheme at a false positive rate of 0.71 per image increased by 2.4% and 0.8%, respectively. The study demonstrated that supplementary information can be derived by computing global mammographic density image features to improve CAD-cueing performance on the suspicious mammographic lesions. PMID:27997380
de Miranda, E J F Peixoto; Bittencourt, M S; Staniak, H L; Sharovsky, R; Pereira, A C; Foppa, M; Santos, I S; Lotufo, P A; Benseñor, I M
2018-03-15
Data on the association between subclinical thyroid dysfunction and coronary artery disease (CAD) is scarce. We aimed to analyze the association between thyroid function and CAD using baseline data from the Brazilian Longitudinal Study of Adult Health (ELSA-Brasil). We included subjects with normal thyroid function (0.4-4.0 mIU/L, and normal free thyroxine, FT4, or 0.8 to 1.9 ng/dL), subclinical hypothyroidism (SCHypo; TSH>4.0 mIU/L and normal FT4), and subclinical hyperthyroidism (SCHyper; TSH<0.4 mIU/L and normal FT4) evaluated by coronary computed tomography angiography. We excluded individuals using medications that interfere in thyroid function or with past medical history of cardiovascular disease. Logistic regression models evaluated the presence of CAD, segment involvement score (SIS) >4, and segment severity score (SSS) >4 of coronary arteries as the dependent variables, and quintiles of TSH and FT4 as the independent variables, adjusted for demographical data and cardiovascular risk factors. We included 767 subjects, median age 58 years (IQR=55-63), 378 (49.3%) women, 697 euthyroid (90.9%), 57 (7.4%) with SCHypo, and 13 (1.7%) with SCHyper. No association between TSH and FT4 quintiles and CAD prevalence was noted. Similarly, no association between TSH levels and the extent or severity of CAD, represented by SIS>4 and SSS>4 were seen. Restricting analysis to euthyroid subjects did not alter the results. TSH levels were not significantly associated with the presence, extent, or severity of CAD in a middle-aged healthy population.
Prolonged survival of reconstituted skin grafts without immunosuppression.
Sasamoto, Y; Alexander, J W; Babcock, G F
1990-01-01
Reconstituted skin composed of a cultured allogeneic epithelial sheet (CAES) and a cultured allogeneic dermis (CAD) was evaluated in a rat model to determine whether it could survive for a prolonged period without immunosuppression. Additionally, free CAD grafts were evaluated for their suitability as dermal substitutes. Male Buffalo rats were used as donors and male Lewis rats as recipients. Split-thickness skin obtained from Buffalo rats was separated into epidermis and dermis by means of Dispase II enzyme. The epidermal layers were minced and trypsinized. Then dispersed single keratinocytes were inoculated onto a irradiated 3T3 cell feeder layer. After a suitable period, a confluent cultured keratinocyte layer was detached and provided CAES grafts. Cultured allogeneic dermis grafts were prepared from cultures of the dermal component. Cultured allogeneic dermis grafts, covered by split thickness isografts (STIG) or local skin flaps, became revascularized at a rate of 94.6% and 90.9%, respectively, 7 days after grafting. However, only 25% of CAD grafts covered by synthetic materials became vascularized. Four types of wound coverage were compared including: (1) CAES grafts, (2) CAES over CAD grafts, (3) split-thickness isografts, and (4) STIG over CAD grafts. In groups 2 and 4, CAD grafts were applied 7 days before CAES grafts or STIG. Grafts of groups 1 and 2 were successful in only 36.7% and 31.1% of the animals and resulted in a high rate of wound contracture--72.4%, 66.7%, respectively. On the other hand, in groups 3 and 4, higher average rates of revascularization (92.0% and 88.3%) and lower rates of wound contracture (25.4% and 24.2%) were obtained.(ABSTRACT TRUNCATED AT 250 WORDS)
Risk factors for lack of statin therapy in patients with diabetes and coronary artery disease.
Zhang, Huabing; Plutzky, Jorge; Shubina, Maria; Turchin, Alexander
Patients with both diabetes and coronary artery disease (CAD) have exceedingly high cardiovascular risk. Nevertheless, little is known about prevalence of statin therapy in this population and reasons why some patients may not be receiving this potentially life-saving treatment. To investigate prevalence and predictors of statin therapy in patients with combined diabetes and CAD. We conducted a retrospective cohort study of primary care patients with diabetes and CAD followed at 2 academic medical centers between 2000 and 2011. We used multivariable logistic regression to identify patient and provider characteristics associated with (1) statin initiation (any history of statin therapy) and (2) statin persistence (active statin prescription at the study end). Of 8488 study patients, 7427 (87.5%) ever received statins and 6212 (73.2%) had persistent statin therapy. Younger age (odds ratio [OR], 1.26 per decade), smoking (OR, 1.49) and cardiologist evaluation (OR, 2.26) were associated with statin initiation (P < .0001 for all). Younger age (OR, 1.17), family history of CAD (OR, 1.39), no adverse reactions to statins (OR, 1.40; P < .0001 for all), female sex (OR, 1.22; P = .005), history of smoking (OR, 1.22; P = .003), cardiologist evaluation (OR, 1.23; P = .002), and lower HbA1c (OR, 1.04; P = 0.003) were associated with persistent statin therapy. Only 362 (29.8%) of the 1215 patients without persistent statin therapy had tried at least 2 statins, and 58 (4.8%) tried 3 statins. Many patients with combined CAD and diabetes are not treated with statins, although in this very high-risk group, even moderate-intensity statins result in meaningful reductions in cardiovascular events. Higher cardiovascular risk and cardiologist evaluation were associated with higher prevalence of statin therapy. Copyright © 2016 National Lipid Association. Published by Elsevier Inc. All rights reserved.
Henriksen, Emilie L; Carlsen, Jonathan F; Vejborg, Ilse Mm; Nielsen, Michael B; Lauridsen, Carsten A
2018-01-01
Background Early detection of breast cancer (BC) is crucial in lowering the mortality. Purpose To present an overview of studies concerning computer-aided detection (CAD) in screening mammography for early detection of BC and compare diagnostic accuracy and recall rates (RR) of single reading (SR) with SR + CAD and double reading (DR) with SR + CAD. Material and Methods PRISMA guidelines were used as a review protocol. Articles on clinical trials concerning CAD for detection of BC in a screening population were included. The literature search resulted in 1522 records. A total of 1491 records were excluded by abstract and 18 were excluded by full text reading. A total of 13 articles were included. Results All but two studies from the SR vs. SR + CAD group showed an increased sensitivity and/or cancer detection rate (CDR) when adding CAD. The DR vs. SR + CAD group showed no significant differences in sensitivity and CDR. Adding CAD to SR increased the RR and decreased the specificity in all but one study. For the DR vs. SR + CAD group only one study reported a significant difference in RR. Conclusion All but two studies showed an increase in RR, sensitivity and CDR when adding CAD to SR. Compared to DR no statistically significant differences in sensitivity or CDR were reported. Additional studies based on organized population-based screening programs, with longer follow-up time, high-volume readers, and digital mammography are needed to evaluate the efficacy of CAD.
Hamza, Tamer A; Sherif, Rana M
2017-06-01
Dental laboratories use different computer-aided design and computer-aided manufacturing (CAD-CAM) systems to fabricate fixed prostheses; however, limited evidence is available concerning which system provides the best marginal discrepancy. The purpose of this in vitro study was to evaluate the marginal fit of 5 different monolithic zirconia restorations milled with different CAD-CAM systems. Thirty monolithic zirconia crowns were fabricated on a custom-designed stainless steel die and were divided into 5 groups according to the type of monolithic zirconia crown and the CAD-CAM system used: group TZ, milled with an MCXL milling machine; group CZ, translucent zirconia milled with a motion milling machine; group ZZ, zirconia milled with a dental milling unit; group PZ, translucent zirconia milled with a zirconia milling unit; and group BZ, solid zirconia milled using an S1 VHF milling machine. The marginal fit was measured with a binocular microscope at an original magnification of ×100. The results were tabulated and statistically analyzed with 1-way ANOVA and post hoc surface range test, and pairwise multiple comparisons were made using Bonferroni correction (α=.05). The type of CAD-CAM used affected the marginal fit of the monolithic restoration. The mean (±SD) highest marginal discrepancy was recorded in group TZI at 39.3 ±2.3 μm, while the least mean marginal discrepancy was recorded in group IZ (22.8 ±8.9 μm). The Bonferroni post hoc test showed that group TZI was significantly different from all other groups tested (P<.05). Within the limitation of this in vitro study, all tested CAD-CAM systems produced monolithic zirconia restorations with clinically acceptable marginal discrepancies; however, the CAD-CAM system with the 5-axis milling unit produced the best marginal fit. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Evaluation of Shipbuilding CAD/CAM/CIM Systems - Phase II (Requirements for Future Systems)
1997-02-01
INNOVATION MARINE INDUSTRY STANDARDS WELDING INDUSTRIAL ENGINEERING EDUCATION AND TRAINING THE NATIONAL SHIPBUILDING RESEARCH PROGRAM February 1997 NSRP 0479...an analysis of CAD/CAM/CIM in shipyards, ship-design software firms, and alIied industries in Europe, Japan and the U.S. The purpose of the analysis...possible: Black and Veatch Hitachi Ariake Works Industrial Technology Institute Intergraph Corporation Kockums Computer Systems Mitsubishi Heavy Industries
Bradley, Charles W.; Morris, Daniel O.; Rankin, Shelley C.; Cain, Christine L.; Misic, Ana M.; Houser, Timothy; Mauldin, Elizabeth A.; Grice, Elizabeth A.
2016-01-01
Host-microbe interactions may play a fundamental role in the pathogenesis of atopic dermatitis (AD), a chronic relapsing inflammatory skin disorder characterized by universal colonization with Staphylococcus. To examine the relationship between epidermal barrier function and the cutaneous microbiota in AD, this study employed a spontaneous model of canine AD (cAD). In a cohort of 14 dogs with cAD, the skin microbiota was longitudinally evaluated with parallel assessment of skin barrier function at disease flare, during antimicrobial therapy and posttherapy. Sequencing of the bacterial 16S ribosomal RNA gene revealed decreased bacterial diversity and increased proportions of Staphylococcus (S. pseudintermedius in particular) and Corynebacterium in comparison to a cohort of healthy control dogs (n=16). Treatment restored bacterial diversity with decreased Staphylococcus proportions, concurrent with decreased cAD severity. Skin barrier function, as measured by corneometry, pH, and transepidermal water loss (TEWL) also normalized with treatment. Bacterial diversity correlated with TEWL and pH, but not corneometry. These findings provide insights into the relationship between the cutaneous microbiome and skin barrier function in AD, the impact of antimicrobial therapy on the skin microbiome, and highlight the utility of cAD as a spontaneous non-rodent model of AD. PMID:26854488
Ulusoy, Nuran
2017-01-01
The aim of this study was to evaluate the effects of two endocrown designs and computer aided design/manufacturing (CAD/CAM) materials on stress distribution and failure probability of restorations applied to severely damaged endodontically treated maxillary first premolar tooth (MFP). Two types of designs without and with 3 mm intraradicular extensions, endocrown (E) and modified endocrown (ME), were modeled on a 3D Finite element (FE) model of the MFP. Vitablocks Mark II (VMII), Vita Enamic (VE), and Lava Ultimate (LU) CAD/CAM materials were used for each type of design. von Mises and maximum principle values were evaluated and the Weibull function was incorporated with FE analysis to calculate the long term failure probability. Regarding the stresses that occurred in enamel, for each group of material, ME restoration design transmitted less stress than endocrown. During normal occlusal function, the overall failure probability was minimum for ME with VMII. ME restoration design with VE was the best restorative option for premolar teeth with extensive loss of coronal structure under high occlusal loads. Therefore, ME design could be a favorable treatment option for MFPs with missing palatal cusp. Among the CAD/CAM materials tested, VMII and VE were found to be more tooth-friendly than LU. PMID:29119108
Motawi, Tarek M K; Mahdy, Soliman G; El-Sawalhi, Maha M; Ali, Eman N; El-Telbany, Rania Farag A
2018-01-01
Cardiovascular diseases (CVD) are the leading cause of death in the diabetic population. Obesity is a serious problem that has been linked with CVD and diabetes via a variety of adipokines. The aims of this study were to evaluate and correlate circulating chemerin, apelin, vaspin, and omentin-1 levels in obese type 2 diabetic Egyptian patients with coronary artery stenosis (CAS), and to assess their usefulness as noninvasive diagnostic biomarkers. Chemerin, apelin, vaspin, and omentin-1 levels were determined by enzyme immunoassay in coronary artery disease (CAD) I patients (45 non-obese, nondiabetic with CAS), CAD II patients (45 obese, diabetic with CAS), and 30 controls. Patients in CAD I and CAD II groups exhibited higher levels of chemerin and apelin together with lower levels of vaspin and omentin-1 than in controls. These alterations were more significant in CAD II than in CAD I patients. Additionally, adipokine levels were individually correlated with each other and with certain biochemical variables. Moreover, chemerin and vaspin levels could differentiate CAD II patients from CAD I and controls. Alterations of these adipokines may play a crucial role in the pathogenesis of CAS in obese type 2 diabetic Egyptian patients. Chemerin and vaspin could be used as markers to support diagnosis of CAS.
Infantino, M; Meacci, F; Grossi, V; Manfredi, M; Benucci, M; Merone, M; Soda, P
2017-02-01
According to the recent recommendations of the American College of Rheumatology, ANA Task Force, IIF technique should be considered the gold standard in antinuclear antibodies (ANAs) testing. To overcome the lack of standardization, biomedical industries have developed several computer-aided diagnosis (CAD) systems. Two hundred and sixty-one consecutive samples with suspected autoimmune diseases were tested for ANA by means of IIF on routinely HEp-2 assay kit (Euroimmun AG). Assignment of result was made if consensus for positive/negative was reached by at least 2 out of 3 expert physicians. ANA-IIF was also carried out using 3 CAD systems: Zenit G-Sight (n = 84), Helios (n = 85) and NOVA View (n = 92); human evaluation was repeated on the same substrate of each CAD system (Immco, Aesku and Inova HEp-2 cells, respectively). To anonymize the results, we randomly named these three systems as A, B and C. We ran a statistical analysis computing several measures of agreement between the ratings, and we also improved the evaluation by using the Wilcoxon's test for nonparametric data. Agreement between the human readings on routinely HEp-2 assay kit and human readings on CAD HEp-2 assay was substantial for A (k = 0.82) and B (k = 0.72), and almost perfect for C (k = 0.89). Such readings were statistically different only in case A. Comparing experts' readings with the readings of CAD systems, when the samples were prepared using CAD HEp-2 assay kits, we found almost perfect agreement for B and C (k = 0.86; k = 0.82) and substantial agreement for A (k = 0.73). Again, human and CAD readings were statistically different only in A. When we compared the readings of medical experts on routinely HEp-2 assay kit with the output of the CAD systems that worked using their own slides, we found substantial agreement for all the systems (A: k = 0.62; B: k = 0.65; C: k = 0.71). Such readings were not statistically different. The change of the assay kit and/or the introduction of a CAD system affect the laboratory reporting, with an evident impact on the autoimmune laboratory workflow. The CAD systems may represent one of the most important novel elements of harmonization in the autoimmunity field, reducing intra- and inter-laboratory variability in a new vision of the diagnostic autoimmune platform.
Comparative in vitro evaluation of CAD/CAM vs conventional provisional crowns
ABDULLAH, Adil Othman; TSITROU, Effrosyni A; POLLINGTON, Sarah
2016-01-01
ABSTRACT Objective This study compared the marginal gap, internal fit, fracture strength, and mode of fracture of CAD/CAM provisional crowns with that of direct provisional crowns. Material and Methods An upper right first premolar phantom tooth was prepared for full ceramic crown following tooth preparation guidelines. The materials tested were: VITA CAD-Temp®, Polyetheretherketone “PEEK”, Telio CAD-Temp, and Protemp™4 (control group). The crowns were divided into four groups (n=10), Group1: VITA CAD-Temp®, Group 2: PEEK, Group 3: Telio CAD-Temp, and Group 4: Protemp™4. Each crown was investigated for marginal and internal fit, fracture strength, and mode of fracture. Statistical analysis was performed using GraphPad Prism software version 6.0. Results The average marginal gap was: VITA CAD-Temp® 60.61 (±9.99) µm, PEEK 46.75 (±8.26) µm, Telio CAD-Temp 56.10 (±5.65) µm, and Protemp™4 193.07(±35.96) µm (P<0.001). The average internal fit was: VITA CAD-Temp® 124.94 (±22.96) µm, PEEK 113.14 (±23.55) µm, Telio CAD-Temp 110.95 (±11.64) µm, and Protemp™4 143.48(±26.74) µm. The average fracture strength was: VITA CAD-Temp® 361.01 (±21.61) N, PEEK 802.23 (±111.29) N, Telio CAD-Temp 719.24 (±95.17) N, and Protemp™4 416.40 (±69.14) N. One-way ANOVA test showed a statistically significant difference for marginal gap, internal gap, and fracture strength between all groups (p<0.001). However, the mode of fracture showed no differences between the groups (p>0.05). Conclusions CAD/CAM fabricated provisional crowns demonstrated superior fit and better strength than direct provisional crowns. PMID:27383707
Comparative in vitro evaluation of CAD/CAM vs conventional provisional crowns.
Abdullah, Adil Othman; Tsitrou, Effrosyni A; Pollington, Sarah
2016-01-01
This study compared the marginal gap, internal fit, fracture strength, and mode of fracture of CAD/CAM provisional crowns with that of direct provisional crowns. An upper right first premolar phantom tooth was prepared for full ceramic crown following tooth preparation guidelines. The materials tested were: VITA CAD-Temp®, Polyetheretherketone "PEEK", Telio CAD-Temp, and Protemp™4 (control group). The crowns were divided into four groups (n=10), Group1: VITA CAD-Temp®, Group 2: PEEK, Group 3: Telio CAD-Temp, and Group 4: Protemp™4. Each crown was investigated for marginal and internal fit, fracture strength, and mode of fracture. Statistical analysis was performed using GraphPad Prism software version 6.0. The average marginal gap was: VITA CAD-Temp® 60.61 (±9.99) µm, PEEK 46.75 (±8.26) µm, Telio CAD-Temp 56.10 (±5.65) µm, and Protemp™4 193.07(±35.96) µm (P<0.001). The average internal fit was: VITA CAD-Temp® 124.94 (±22.96) µm, PEEK 113.14 (±23.55) µm, Telio CAD-Temp 110.95 (±11.64) µm, and Protemp™4 143.48(±26.74) µm. The average fracture strength was: VITA CAD-Temp® 361.01 (±21.61) N, PEEK 802.23 (±111.29) N, Telio CAD-Temp 719.24 (±95.17) N, and Protemp™4 416.40 (±69.14) N. One-way ANOVA test showed a statistically significant difference for marginal gap, internal gap, and fracture strength between all groups (p<0.001). However, the mode of fracture showed no differences between the groups (p>0.05). CAD/CAM fabricated provisional crowns demonstrated superior fit and better strength than direct provisional crowns.
Andrade, Weslley Santiago; Oliveira, Paulo; Laydner, Humberto; Ferreira, Eduardo Jose Pereira; Barreto, Jose Augusto Soares
2016-01-01
ABSTRACT Objective To investigate the association between the severity of erectile dysfunction (ED) and coronary artery disease (CAD) in men undergoing coronary angiography for angina or acute myocardial infarct (AMI). Material and Methods We studied 132 males who underwent coronary angiography for first time between January and November 2010. ED severity was assessed by the international index of erectile function (IIEF-5) and CAD severity was assessed by the Syntax score. Patients with CAD (cases) and without CAD (controls) had their IIEF-5 compared. In the group with CAD, their IIEF-5 scores were compared to their Syntax score results. Results We identified 86 patients with and 46 without CAD. The IIEF-5 score of the group without CAD (22.6±0.8) was significantly higher than the group with CAD (12.5±0.5; p<0.0001). In patients without ED, the Syntax score average was 6.3±3.5, while those with moderate or severe ED had a mean Syntax score of 39.0±11.1. After adjustment, ED was independently associated to CAD, with an odds ratio of 40.6 (CI 95%, 14.3-115.3, p<0.0001). The accuracy of the logistic model to correctly identify presence or absence of CAD was 87%, with 92% sensitivity and 78% specificity. The average time that ED was present in patients with CAD was 38.8±2.3 months before coronary symptoms, about twice as high as patients without CAD (18.0±5.1 months). Conclusions ED severity is strongly and independently correlated with CAD complexity, as assessed by the Syntax score in patients undergoing coronariography for evaluation of new onset coronary symptoms. PMID:27136478
Mechanical properties and superficial characterization of a milled CAD-CAM glass fiber post.
Ruschel, George Hebert; Gomes, Érica Alves; Silva-Sousa, Yara Terezinha; Pinelli, Rafaela Giedra Pirondi; Sousa-Neto, Manoel Damião; Pereira, Gabriel Kalil Rocha; Spazzin, Aloísio Oro
2018-06-01
Computer-aided design and computer-aided manufacturing (CAD-CAM) technology may be used to produce custom intraradicular posts, but studies are lacking. The purpose of this in vitro study was to evaluate the flexural properties (strength and modulus), failure mode, superficial morphology, and roughness of two CAD-CAM glass fiber posts (milled at different angulations) compared with a commercially available prefabricated glass fiber post. Three groups were tested (n = 10): PF (control group)- prefabricated glass fiber post; C-Cd-diagonally milled post; and C-Cv-vertically milled post. A 3-dimensional virtual image was obtained from a prefabricated post, which guided the posterior milling of posts from a glass fiber disk (Trilor Blanks; Bioloren). Surface roughness and morphology were evaluated using confocal laser microscopy. Flexural strength and modulus were evaluated with the 3-point bend test. Data were submitted to one-way analysis of variance followed by the Student-Newman-Keuls post hoc test (α = 0.05). The fractured surfaces were evaluated with scanning electron microscopy. The superficial roughness was highest for PF and similar for the experimental groups. Morphological analysis shows different sizes and directions of the glass fibers along the post. The flexural strength was highest for PF (900.1 ± 30.4 > C-Cd - 357.2 ± 30.7 > C-Cv 101.8 ± 4.3 MPa) as was the flexural modulus (PF 19.3 ± 2.0 GPa > C-Cv 10.1 ± 1.9 GPa > C-Cd 7.8 ± 1.3 GPa). A CAD-CAM milled post seems a promising development, but processing requires optimizing, as the prefabricated post still shows better mechanical properties and superficial characteristics. Copyright © 2018 Elsevier Ltd. All rights reserved.
Shaw, Leslee J.; Bairey Merz, C. Noel; Azziz, Ricardo; Stanczyk, Frank Z.; Sopko, George; Braunstein, Glenn D.; Kelsey, Sheryl F.; Kip, Kevin E.; Cooper-DeHoff, Rhonda M.; Johnson, B. Delia; Vaccarino, Viola; Reis, Steven E.; Bittner, Vera; Hodgson, T. Keta; Rogers, William; Pepine, Carl J.
2008-01-01
Background: Women with polycystic ovary syndrome (PCOS) have a greater clustering of cardiac risk factors. However, the link between PCOS and cardiovascular (CV) disease is incompletely described. Objective: The aim of this analysis was to evaluate the risk of CV events in 390 postmenopausal women enrolled in the National Institutes of Health–National Heart, Lung, and Blood Institute (NIH-NHLBI) sponsored Women’s Ischemia Syndrome Evaluation (WISE) study according to clinical features of PCOS. Methods: A total of 104 women had clinical features of PCOS defined by a premenopausal history of irregular menses and current biochemical evidence of hyperandrogenemia. Hyperandrogenemia was defined as the top quartile of androstenedione (≥701 pg/ml), testosterone (≥30.9 ng/dl), or free testosterone (≥4.5 pg/ml). Cox proportional hazard model was fit to estimate CV death or myocardial infarction (n = 55). Results: Women with clinical features of PCOS were more often diabetic (P < 0.0001), obese (P = 0.005), had the metabolic syndrome (P < 0.0001), and had more angiographic coronary artery disease (CAD) (P = 0.04) compared to women without clinical features of PCOS. Cumulative 5-yr CV event-free survival was 78.9% for women with clinical features of PCOS (n = 104) vs. 88.7% for women without clinical features of PCOS (n = 286) (P = 0.006). PCOS remained a significant predictor (P < 0.01) in prognostic models including diabetes, waist circumference, hypertension, and angiographic CAD as covariates. Conclusion: Among postmenopausal women evaluated for suspected ischemia, clinical features of PCOS are associated with more angiographic CAD and worsening CV event-free survival. Identification of postmenopausal women with clinical features of PCOS may provide an opportunity for risk factor intervention for the prevention of CAD and CV events. PMID:18182456
Shaw, Leslee J; Bairey Merz, C Noel; Azziz, Ricardo; Stanczyk, Frank Z; Sopko, George; Braunstein, Glenn D; Kelsey, Sheryl F; Kip, Kevin E; Cooper-Dehoff, Rhonda M; Johnson, B Delia; Vaccarino, Viola; Reis, Steven E; Bittner, Vera; Hodgson, T Keta; Rogers, William; Pepine, Carl J
2008-04-01
Women with polycystic ovary syndrome (PCOS) have a greater clustering of cardiac risk factors. However, the link between PCOS and cardiovascular (CV) disease is incompletely described. The aim of this analysis was to evaluate the risk of CV events in 390 postmenopausal women enrolled in the National Institutes of Health-National Heart, Lung, and Blood Institute (NIH-NHLBI) sponsored Women's Ischemia Syndrome Evaluation (WISE) study according to clinical features of PCOS. A total of 104 women had clinical features of PCOS defined by a premenopausal history of irregular menses and current biochemical evidence of hyperandrogenemia. Hyperandrogenemia was defined as the top quartile of androstenedione (> or = 701 pg/ml), testosterone (> or = 30.9 ng/dl), or free testosterone (> or = 4.5 pg/ml). Cox proportional hazard model was fit to estimate CV death or myocardial infarction (n = 55). Women with clinical features of PCOS were more often diabetic (P < 0.0001), obese (P = 0.005), had the metabolic syndrome (P < 0.0001), and had more angiographic coronary artery disease (CAD) (P = 0.04) compared to women without clinical features of PCOS. Cumulative 5-yr CV event-free survival was 78.9% for women with clinical features of PCOS (n = 104) vs. 88.7% for women without clinical features of PCOS (n = 286) (P = 0.006). PCOS remained a significant predictor (P < 0.01) in prognostic models including diabetes, waist circumference, hypertension, and angiographic CAD as covariates. Among postmenopausal women evaluated for suspected ischemia, clinical features of PCOS are associated with more angiographic CAD and worsening CV event-free survival. Identification of postmenopausal women with clinical features of PCOS may provide an opportunity for risk factor intervention for the prevention of CAD and CV events.
Reliability and mode of failure of bonded monolithic and multilayer ceramics.
Alessandretti, Rodrigo; Borba, Marcia; Benetti, Paula; Corazza, Pedro Henrique; Ribeiro, Raissa; Della Bona, Alvaro
2017-02-01
To evaluate the reliability of monolithic and multilayer ceramic structures used in the CAD-on technique (Ivoclar), and the mode of failure produced in ceramic structures bonded to a dentin analog material (NEMA-G10). Ceramic specimens were fabricated as follows (n=30): CAD-on- trilayer structure (IPS e.max ZirCAD/IPS e.max Crystall./Connect/IPS e.max CAD); YLD- bilayer structure (IPS e.max ZirCAD/IPS e.max Ceram); LDC- monolithic structure (IPS e.max CAD); and YZW- monolithic structure (Zenostar Zr Translucent). All ceramic specimens were bonded to G10 and subjected to compressive load in 37°C distilled water until the sound of the first crack, monitored acoustically. Failure load (L f ) values were recorded (N) and statistically analyzed using Weibull distribution, Kruskal-Wallis test, and Student-Newman-Keuls test (α=0.05). L f values of CAD-on and YZW structures were statistically similar (p=0.917), but higher than YLD and LDC (p<0.01). Weibull modulus (m) values were statistically similar for all experimental groups. Monolithic structures (LDC and YZW) failed from radial cracks. Failures in the CAD-on and YLD groups showed, predominantly, both radial and cone cracks. Monolithic zirconia (YZW) and CAD-on structures showed similar failure resistance and reliability, but a different fracture behavior. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
van Zelst, J C M; Tan, T; Platel, B; de Jong, M; Steenbakkers, A; Mourits, M; Grivegnee, A; Borelli, C; Karssemeijer, N; Mann, R M
2017-04-01
To investigate the effect of dedicated Computer Aided Detection (CAD) software for automated breast ultrasound (ABUS) on the performance of radiologists screening for breast cancer. 90 ABUS views of 90 patients were randomly selected from a multi-institutional archive of cases collected between 2010 and 2013. This dataset included normal cases (n=40) with >1year of follow up, benign (n=30) lesions that were either biopsied or remained stable, and malignant lesions (n=20). Six readers evaluated all cases with and without CAD in two sessions. CAD-software included conventional CAD-marks and an intelligent minimum intensity projection of the breast tissue. Readers reported using a likelihood-of-malignancy scale from 0 to 100. Alternative free-response ROC analysis was used to measure the performance. Without CAD, the average area-under-the-curve (AUC) of the readers was 0.77 and significantly improved with CAD to 0.84 (p=0.001). Sensitivity of all readers improved (range 5.2-10.6%) by using CAD but specificity decreased in four out of six readers (range 1.4-5.7%). No significant difference was observed in the AUC between experienced radiologists and residents both with and without CAD. Dedicated CAD-software for ABUS has the potential to improve the cancer detection rates of radiologists screening for breast cancer. Copyright © 2017 Elsevier B.V. All rights reserved.
Chen, B W; Xiao, Y F; Li, J J; Liu, H L; Qin, Z H; Gai, Y; Jiang, X N
2016-12-02
Cinnamyl alcohol dehydrogenase (CAD) catalyzes the final step in lignin biosynthesis. The genus Eucalyptus belongs to the family Myrtaceae, which is the main cultivated species in China. Eucalyptus urophylla GLU4 (GLU4) is widely grown in Guangxi. It is preferred for pulping because of its excellent cellulose content and fiber length. Based on GLU4 and CAD gene expression, a Eucalyptus variety low in lignin content should be obtained using transgenic technology, which could reduce the cost of pulp and improve the pulping rate, and have favorable prospects for application. However, the role and function of CAD in GLU4 is still unclear. In the present study, EuCAD was cloned from GLU4 and identified using bioinformatic tools. Subsequently, in order to evaluate its impact on lignin synthesis, a full-length EuCAD RNAi vector was constructed, and transgenic tobacco was obtained via Agrobacterium-mediated transformation. A significant decrease in CAD expression and lignin content in transgenic tobacco demonstrated a key role for EuCAD in lignin biosynthesis and established a regulatory role for RNAi. In our study, the direct molecular basis of EuCAD expression was determined, and the potential regulatory effects of this RNAi vector on lignin biosynthesis in E. urophylla GLU4 were demonstrated. Our results provide a theoretical basis for the study of lignin biosynthesis in Eucalyptus.
Adatia, Falisha; Galway, Shannon; Grubisic, Maja; Lee, May; Daniele, Patrick; Humphries, Karin H; Sedlak, Tara L
2017-11-01
Patients with acute myocardial infarction (MI) and nonobstructive coronary artery disease (CAD) have an elevated cardiac event rate, suggesting that these patients may benefit from cardiac medication. We evaluated the rates of cardiac medication use 3 months before angiography and 3 months following clinically indicated angiography for MI in patients with no CAD, nonobstructive CAD, and obstructive CAD. We also examined the sex differences in cardiac medication use 3 months following angiography in patients by extent of angiographic CAD. We studied patients ≥20 years old with MI undergoing coronary angiography in British Columbia, Canada, from January 1, 2008, to March 31, 2010 (n = 3,841). No CAD, nonobstructive CAD, and obstructive CAD were defined as 0%, 1% to 49%, and ≥50% luminal narrowing in any epicardial coronary artery, respectively. Medication use, 3 months before and 3 months following angiography, was obtained through British Columbia PharmaNet for angiotensin-converting enzyme inhibitors (ACE-Is), angiotensin receptor blockers (ARBs), calcium channel blockers (CCBs), beta-blockers, statins, and antiplatelet agents. Optimal medical therapy (OMT) was defined as filled prescriptions for all three: ACE-Is/ARBs, beta-blockers, and statins. Following angiography, in all medication categories except CCBs, patients with no CAD and nonobstructive CAD had significantly lower rates of prescriptions filled than patients with obstructive CAD (all p < 0.001). After adjusting for age and prior medication use, patients with nonobstructive CAD were still less likely to receive these medications than patients with obstructive CAD, including OMT with an odds ratio = 0.25 (95% confidence interval: 0.18-0.36). There were no significant sex differences in medication use 3 months postangiography. In post-MI patients, medication use following angiography is significantly lower in nonobstructive CAD than obstructive CAD at 3 months. While sex was not an independent predictor of medication use 3 months post-catheterization, future studies should explore methods of improving medication use in both females and males with nonobstructive CAD post-MI.
Chu, Wern Cui; Aziz, Ahmad Fazli Abdul; Nordin, Abdul Jalil; Cheah, Yoke Kqueen
2016-09-01
Genetic variants of cholesteryl ester transfer protein (CETP) and endothelial nitric oxide synthase (eNOS) influence high-density lipoprotein cholesterol (HDL-C) metabolism and nitric oxide (NO) synthesis, respectively, and might increase the risk of coronary artery disease (CAD). This study is to investigate the relationship between genetic polymorphisms and the risk of CAD and to evaluate their potential interactions. A total of 237 patients with CAD and 101 controls were genotyped. The association of the polymorphism with the risk of CAD varied among the ethnic groups. Moreover, the concomitant presence of both CETP B1 and eNOS 4a alleles significantly increased the risk of CAD in the Malay group (OR = 33.8, P < .001) and the Indian group (OR = 10.9, P = .031) but not in the Chinese group. This study has identified a novel ethnic-specific gene-gene interaction and suggested that the combination of CETP B1 allele and eNOS 4a allele significantly increases the risk of CAD in Malays and Indians. © The Author(s) 2015.
Den Harder, Annemarie M; Willemink, Martin J; van Hamersvelt, Robbert W; Vonken, Evert-Jan P A; Milles, Julien; Schilham, Arnold M R; Lammers, Jan-Willem; de Jong, Pim A; Leiner, Tim; Budde, Ricardo P J
2016-02-01
To evaluate the effect of radiation dose reduction and iterative reconstruction (IR) on the performance of computer-aided detection (CAD) for pulmonary nodules. In this prospective study twenty-five patients were included who were scanned for pulmonary nodule follow-up. Image acquisition was performed at routine dose and three reduced dose levels in a single session by decreasing mAs-values with 45%, 60% and 75%. Tube voltage was fixed at 120 kVp for patients ≥ 80 kg and 100 kVp for patients < 80 kg. Data were reconstructed with filtered back projection (FBP), iDose(4) (levels 1,4,6) and IMR (levels 1-3). All noncalcified solid pulmonary nodules ≥ 4 mm identified by two radiologists in consensus served as the reference standard. Subsequently, nodule volume was measured with CAD software and compared to the reference consensus. The numbers of true-positives, false-positives and missed pulmonary nodules were evaluated as well as the sensitivity. Median effective radiation dose was 2.2 mSv at routine dose and 1.2, 0.9 and 0.6 mSv at respectively 45%, 60% and 75% reduced dose. A total of 28 pulmonary nodules were included. With FBP at routine dose, 89% (25/28) of the nodules were correctly identified by CAD. This was similar at reduced dose levels with FBP, iDose(4) and IMR. CAD resulted in a median number of false-positives findings of 11 per scan with FBP at routine dose (93% of the CAD marks) increasing to 15 per scan with iDose(4) (95% of the CAD marks) and 26 per scan (96% of the CAD marks) with IMR at the lowest dose level. CAD can identify pulmonary nodules at submillisievert dose levels with FBP, hybrid and model-based IR. However, the number of false-positive findings increased using hybrid and especially model-based IR at submillisievert dose while dose reduction did not affect the number of false-positives with FBP. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Guess, Petra C; Vagkopoulou, Thaleia; Zhang, Yu; Wolkewitz, Martin; Strub, Joerg R
2014-02-01
The aim of the study was to evaluate the marginal and internal fit of heat-pressed and CAD/CAM fabricated all-ceramic onlays before and after luting as well as after thermo-mechanical fatigue. Seventy-two caries-free, extracted human mandibular molars were randomly divided into three groups (n=24/group). All teeth received an onlay preparation with a mesio-occlusal-distal inlay cavity and an occlusal reduction of all cusps. Teeth were restored with heat-pressed IPS-e.max-Press* (IP, *Ivoclar-Vivadent) and Vita-PM9 (VP, Vita-Zahnfabrik) as well as CAD/CAM fabricated IPS-e.max-CAD* (IC, Cerec 3D/InLab/Sirona) all-ceramic materials. After cementation with a dual-polymerising resin cement (VariolinkII*), all restorations were subjected to mouth-motion fatigue (98 N, 1.2 million cycles; 5°C/55°C). Marginal fit discrepancies were examined on epoxy replicas before and after luting as well as after fatigue at 200× magnification. Internal fit was evaluated by multiple sectioning technique. For the statistical analysis, a linear model was fitted with accounting for repeated measurements. Adhesive cementation of onlays resulted in significantly increased marginal gap values in all groups, whereas thermo-mechanical fatigue had no effect. Marginal gap values of all test groups were equal after fatigue exposure. Internal discrepancies of CAD/CAM fabricated restorations were significantly higher than both press manufactured onlays. Mean marginal gap values of the investigated onlays before and after luting as well as after fatigue were within the clinically acceptable range. Marginal fit was not affected by the investigated heat-press versus CAD/CAM fabrication technique. Press fabrication resulted in a superior internal fit of onlays as compared to the CAD/CAM technique. Clinical requirements of 100 μm for marginal fit were fulfilled by the heat-press as well as by the CAD/CAM fabricated all-ceramic onlays. Superior internal fit was observed with the heat-press manufacturing method. The impact of present findings on the clinical long-term behaviour of differently fabricated all-ceramic onlays warrants further investigation. Copyright © 2013 Elsevier Ltd. All rights reserved.
Okamura, Tomonori; Kokubo, Yoshihiro; Watanabe, Makoto; Higashiyama, Aya; Ono, Yuu; Nishimura, Kunihiro; Okayama, Akira; Miyamoto, Yoshihiro
2011-07-01
Recently, several major organizations have proposed a unified definition for the metabolic syndrome (MetS), which should be evaluated in multiethnic groups. The effect of Mets on the incidence of cardiovascular disease needs to be assessed after adjusting for serum low density lipoprotein cholesterol (LDLC), a major risk factor for atherosclerotic diseases. This is especially needed to be evaluated in Asian populations with low incidence of coronary artery disease (CAD). We conducted a 13-year prospective study of 4939 Japanese living in an urban area. The MetS was defined using a unified classification that included cut-off points for waist circumference in Asians. The multivariable adjusted hazard ratios (HRs) of MetS for CAD and stroke were calculated using a Cox proportional model adjusted for other potential confounding factors with LDLC. During the follow-up period, there were 155 cases of CAD and 204 of stroke including 118 cerebral infarctions. In participants under 65 years old, the multivariable HRs of MetS for CAD were 1.21 (95% C.I., 0.64-2.28) in men and 4.44 (95% C.I., 1.73-11.4) in women; the HRs for ischemic stroke were 3.24 (95% C.I., 1.55-6.77) in men and 3.99 (95% C.I., 1.34-11.8) in women. In participants aged 65 years old and over, MetS only showed a significant association with CAD in men (HR 1.89, 95% C.I., 1.11-3.21). Serum LDLC was associated with increased risk of CAD in men irrespective of age group; however, it was not associated with CAD in women. There was no association between serum LDLC and ischemic stroke in any group stratified by sex and the age of 65. These results indicate that the new uniform MetS definition is useful for detecting high risk individuals, especially for middle-aged population. However, continuous screening for hypercholesterolemia is necessary to prevent CAD, especially in men, even in Asian countries such as Japan. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Presotto, Anna Gabriella Camacho; Bhering, Cláudia Lopes Brilhante; Mesquita, Marcelo Ferraz; Barão, Valentim Adelino Ricardo
2017-03-01
Several studies have shown the superiority of computer-assisted design and computer-assisted manufacturing (CAD-CAM) technology compared with conventional casting. However, an advanced technology exists for casting procedures (the overcasting technique), which may serve as an acceptable and affordable alternative to CAD-CAM technology for fabricating 3-unit implant-supported fixed dental prostheses (FDPs). The purpose of this in vitro study was to evaluate, using quantitative photoelastic analysis, the effect of the prosthetic framework fabrication method (CAD-CAM and overcasting) on the marginal fit and stress transmitted to implants. The correlation between marginal fit and stress was also investigated. Three-unit implant-supported FDP frameworks were made using the CAD-CAM (n=10) and overcasting (n=10) methods. The frameworks were waxed to simulate a mandibular first premolar (PM region) to first molar (M region) FDP using overcast mini-abutment cylinders. The wax patterns were overcast (overcast experimental group) or scanned to obtain the frameworks (CAD-CAM control group). All frameworks were fabricated from cobalt-chromium (CoCr) alloy. The marginal fit was analyzed according to the single-screw test protocol, obtaining an average value for each region (M and PM) and each framework. The frameworks were tightened for the photoelastic model with standardized 10-Ncm torque. Stress was measured by quantitative photoelastic analysis. The results were submitted to the Student t test, 2-way ANOVA, and Pearson correlation test (α=.05). The framework fabrication method (FM) and evaluation site (ES; M and PM regions) did not affect the marginal fit values (P=.559 for FM and P=.065 for ES) and stress (P=.685 for FM and P=.468 for ES) in the implant-supported system. Positive correlations between marginal fit and stress were observed (CAD-CAM: r=0.922; P<.001; overcast: r=0.908; P<.001). CAD-CAM and overcasting methods present similar marginal fit and stress values for 3-unit FDP frameworks. The decreased marginal fit of frameworks induces greater stress in the implant-supported system. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Guess, Petra C.; Vagopoulou, Thaleia; Zhang, Yu; Wolkewitz, Martin; Strub, Joerg R.
2015-01-01
Objectives The aim of the study was to evaluate the marginal and internal fit of heat-pressed and CAD/CAM fabricated all-ceramic onlays before and after luting as well as after thermo-mechanical fatigue. Materials and Methods Seventy-two caries-free, extracted human mandibular molars were randomly divided into three groups (n=24/group). All teeth received an onlay preparation with a mesio-occlusal-distal inlay cavity and an occlusal reduction of all cusps. Teeth were restored with heat-pressed IPS-e.max-Press* (IP, *Ivoclar-Vivadent) and Vita-PM9 (VP, Vita-Zahnfabrik) as well as CAD/CAM fabricated IPS-e.max-CAD* (IC, Cerec 3D/InLab/Sirona) all-ceramic materials. After cementation with a dual-polymerizing resin cement (VariolinkII*), all restorations were subjected to mouth-motion fatigue (98N, 1.2 million cycles; 5°C/55°C). Marginal fit discrepancies were examined on epoxy replicas before and after luting as well as after fatigue at 200x magnification. Internal fit was evaluated by multiple sectioning technique. For the statistical analysis, a linear model was fitted with accounting for repeated measurements. Results Adhesive cementation of onlays resulted in significantly increased marginal gap values in all groups, whereas thermo-mechanical fatigue had no effect. Marginal gap values of all test groups were equal after fatigue exposure. Internal discrepancies of CAD/CAM fabricated restorations were significantly higher than both press manufactured onlays. Conclusions Mean marginal gap values of the investigated onlays before and after luting as well as after fatigue were within the clinically acceptable range. Marginal fit was not affected by the investigated heat-press versus CAD/CAM fabrication technique. Press fabrication resulted in a superior internal fit of onlays as compared to the CAD/CAM technique. Clinical Relevance Clinical requirements of 100 μm for marginal fit were fulfilled by the heat-press as well as by the CAD/CAM fabricated all-ceramic onlays. Superior internal fit was observed with the heat-press manufacturing method. The impact of present findings on the clinical long-term behaviour of differently fabricated all-ceramic onlays warrants further investigation. PMID:24161516
NASA Astrophysics Data System (ADS)
Lee, Joon K.; Chan, Tao; Liu, Brent J.; Huang, H. K.
2009-02-01
Detection of acute intracranial hemorrhage (AIH) is a primary task in the interpretation of computed tomography (CT) brain scans of patients suffering from acute neurological disturbances or after head trauma. Interpretation can be difficult especially when the lesion is inconspicuous or the reader is inexperienced. We have previously developed a computeraided detection (CAD) algorithm to detect small AIH. One hundred and thirty five small AIH CT studies from the Los Angeles County (LAC) + USC Hospital were identified and matched by age and sex with one hundred and thirty five normal studies. These cases were then processed using our AIH CAD system to evaluate the efficacy and constraints of the algorithm.
Elaborate SMART MCNP Modelling Using ANSYS and Its Applications
NASA Astrophysics Data System (ADS)
Song, Jaehoon; Surh, Han-bum; Kim, Seung-jin; Koo, Bonsueng
2017-09-01
An MCNP 3-dimensional model can be widely used to evaluate various design parameters such as a core design or shielding design. Conventionally, a simplified 3-dimensional MCNP model is applied to calculate these parameters because of the cumbersomeness of modelling by hand. ANSYS has a function for converting the CAD `stp' format into an MCNP input in the geometry part. Using ANSYS and a 3- dimensional CAD file, a very detailed and sophisticated MCNP 3-dimensional model can be generated. The MCNP model is applied to evaluate the assembly weighting factor at the ex-core detector of SMART, and the result is compared with a simplified MCNP SMART model and assembly weighting factor calculated by DORT, which is a deterministic Sn code.
Stawarczyk, Bogna; Liebermann, Anja; Eichberger, Marlis; Güth, Jan-Frederik
2015-03-01
To determine the mechanical and optical properties of CAD/CAM composites (LAVA Ultimate, Cerasmart, Shofu Block and two exp. CAD/CAM composites), a hybrid material (VITA Enamic), a leucite (IPS Empress CAD) and a lithium disilicate glass-ceramic (IPS e.max CAD). Three-point flexural strength (FS) was investigated according ISO 6872:2008 (N=240/n=30). Two-body wear (TBW) was analyzed in a chewing simulator (1,200,000 cycles, 50N, 5°/55°C) using human teeth as antagonists (N=120/n=15). Quantitative analysis of wear was carried out with a 3D-scanner and associated matching software. Discoloration rate (DR) after 14 days of storage in cress, curry, red wine, and distilled water (N=384/n=12), and translucency (T) (N=384/n=48) of CAD/CAM materials were measured in a spectrophotometer (400-700nm wavelength). Data were analyzed using two-/one-way ANOVA with Scheffé post-hoc test, Kruskal-Wallis-H test, and linear mixed models (α=0.05). IPS e.max CAD showed the highest FS (p<0.001), followed by LAVA Ultimate; however, not different from the remaining CAD/CAM composites (exception: Shofu Block). The lowest FS showed VITA Enamic and IPS Empress CAD (p<0.001). IPS Empress CAD, VITA Enamic, exp. CAD/CAM composite 2, followed by IPS e.max presented lower material TBW than the remaining CAD/CAM materials (p<0.001). The highest antagonist wear was observed for the tested glass-ceramics and the hybrid material (p<0.001). Storage medium (red wine>curry>cress>distilled water) exerted the highest influence on DR (p<0.001), closely followed by CAD/CAM material. Glass-ceramics showed lower DR than CAD/CAM composites (p<0.001). CAD/CAM composites presented moderate FS, high T and antagonist friendly behavior. Glass-ceramic demonstrated the most favorable DR and lowest TBW on the material side. Copyright © 2015 Elsevier Ltd. All rights reserved.
Li, Feng
2015-07-01
This review paper is based on our research experience in the past 30 years. The importance of radiologists' role is discussed in the development or evaluation of new medical images and of computer-aided detection (CAD) schemes in chest radiology. The four main topics include (1) introducing what diseases can be included in a research database for different imaging techniques or CAD systems and what imaging database can be built by radiologists, (2) understanding how radiologists' subjective judgment can be combined with technical objective features to improve CAD performance, (3) sharing our experience in the design of successful observer performance studies, and (4) finally, discussing whether the new images and CAD systems can improve radiologists' diagnostic ability in chest radiology. In conclusion, advanced imaging techniques and detection/classification of CAD systems have a potential clinical impact on improvement of radiologists' diagnostic ability, for both the detection and the differential diagnosis of various lung diseases, in chest radiology.
Design Through Manufacturing: The Solid Model-Finite Element Analysis Interface
NASA Technical Reports Server (NTRS)
Rubin, Carol
2002-01-01
State-of-the-art computer aided design (CAD) presently affords engineers the opportunity to create solid models of machine parts reflecting every detail of the finished product. Ideally, in the aerospace industry, these models should fulfill two very important functions: (1) provide numerical. control information for automated manufacturing of precision parts, and (2) enable analysts to easily evaluate the stress levels (using finite element analysis - FEA) for all structurally significant parts used in aircraft and space vehicles. Today's state-of-the-art CAD programs perform function (1) very well, providing an excellent model for precision manufacturing. But they do not provide a straightforward and simple means of automating the translation from CAD to FEA models, especially for aircraft-type structures. Presently, the process of preparing CAD models for FEA consumes a great deal of the analyst's time.
Fracture strength testing of crowns made of CAD/CAM composite resins.
Okada, Ryota; Asakura, Masaki; Ando, Akihiro; Kumano, Hirokazu; Ban, Seiji; Kawai, Tatsushi; Takebe, Jun
2018-03-28
The purpose of this study was to ascertain whether computer aided design/computer aided manufacturing (CAD/CAM) composite resin crowns have sufficient strength to withstand the bite force of the molar teeth. The null hypothesis was that the fracture strength of CAD/CAM composite resin crowns is lower than the average maximum bite force of the molar tooth. The crowns, which shape is the right maxillary first molar, were fabricated using four CAD/CAM blanks made of composite resins (Block HC: HC, KZR-CAD HR: HR, KZR-CAD HR2: HR2, Avencia Block: AVE) and one CAD/CAM blank made of lithium disilicate glass-ceramic (IPS e.max CAD: IPS), which was used as a control. Fracture strength of fabricated crowns bonded to metal abutment and biaxial flexural strength of the materials were evaluated. The results of fracture strength test and biaxial flexural strength test showed different tendencies. The fracture strength of CAD/CAM composite resin crowns except HC ranged from 3.3kN to 3.9kN, and was similar to that of IPS (3.3kN). In contrast, biaxial flexural strength of CAD/CAM composite resins ranged from 175MPa to 247MPa, and was significantly lower than that of IPS (360MPa). All CAD/CAM composite resin crowns studied presented about 3-4 times higher fracture strength than the average maximum bite force of the molar tooth (700-900N), which result leads to the conclusion that CAD/CAM composite resin crowns would have sufficient strength to withstand the bite force of the molar teeth. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
Genetic variants associated with celiac disease and the risk for coronary artery disease.
Jansen, Henning; Willenborg, Christina; Schlesinger, Sabrina; Ferrario, Paola G; König, Inke R; Erdmann, Jeanette; Samani, Nilesh J; Lieb, Wolfgang; Schunkert, Heribert
2015-10-01
Epidemiological evidence suggests that patients with celiac disease are at increased risk for coronary artery disease (CAD). Genetic-epidemiological analyses identified many single nucleotide polymorphisms (SNPs) associated with celiac disease. If there is a causal relation between celiac disease and CAD, one might expect that risk alleles primarily associated with celiac disease also increase the risk of CAD. In this study we identified from literature 41 SNPs that have been previously described to be genome-wide associated with celiac disease (p < 5 × 10(-08)). These SNPs were evaluated for their association with CAD in the Coronary ARtery DIsease Genome-wide Replication and Meta-analysis (CARDIoGRAM) dataset, a meta-analysis comprising genome-wide SNP association data from 22,233 CAD cases and 64,762 controls. 24 out of 41 (58.5 %) risk alleles for celiac disease displayed a positive association with CAD (CAD-OR range 1.001-1.081). The remaining risk alleles for celiac disease (n = 16) revealed CAD-ORs of ≤1.0 (range 0.951-1.0). The proportion of CAD associated alleles was greater but did not differ significantly from the proportion of 50 % expected by chance (p = 0.069). One SNP (rs653178 at the SH2B3/ATXN2 locus) displayed study-wise statistically significant association with CAD with directionality consistent effects on celiac disease and CAD. However, the effect of this locus is most likely driven by pleiotropic effects on multiple other diseases. In conclusion, this genetically based approach provided no convincing evidence that SNPs associated with celiac disease contribute to the risk of CAD. Hence, common non-genetic factors may play a more important role explaining the coincidence of these two complex disease conditions.
Network-Based Identification and Prioritization of Key Regulators of Coronary Artery Disease Loci
Zhao, Yuqi; Chen, Jing; Freudenberg, Johannes M.; Meng, Qingying; Rajpal, Deepak K.; Yang, Xia
2017-01-01
Objective Recent genome-wide association studies of coronary artery disease (CAD) have revealed 58 genome-wide significant and 148 suggestive genetic loci. However, the molecular mechanisms through which they contribute to CAD and the clinical implications of these findings remain largely unknown. We aim to retrieve gene subnetworks of the 206 CAD loci and identify and prioritize candidate regulators to better understand the biological mechanisms underlying the genetic associations. Approach and Results We devised a new integrative genomics approach that incorporated (1) candidate genes from the top CAD loci, (2) the complete genetic association results from the 1000 genomes-based CAD genome-wide association studies from the Coronary Artery Disease Genome Wide Replication and Meta-Analysis Plus the Coronary Artery Disease consortium, (3) tissue-specific gene regulatory networks that depict the potential relationship and interactions between genes, and (4) tissue-specific gene expression patterns between CAD patients and controls. The networks and top-ranked regulators according to these data-driven criteria were further queried against literature, experimental evidence, and drug information to evaluate their disease relevance and potential as drug targets. Our analysis uncovered several potential novel regulators of CAD such as LUM and STAT3, which possess properties suitable as drug targets. We also revealed molecular relations and potential mechanisms through which the top CAD loci operate. Furthermore, we found that multiple CAD-relevant biological processes such as extracellular matrix, inflammatory and immune pathways, complement and coagulation cascades, and lipid metabolism interact in the CAD networks. Conclusions Our data-driven integrative genomics framework unraveled tissue-specific relations among the candidate genes of the CAD genome-wide association studies loci and prioritized novel network regulatory genes orchestrating biological processes relevant to CAD. PMID:26966275
Ya, Gao; Qiu, Zhang; Tianrong, Pan
2018-06-01
Atherosclerotic cardiovascular disease is the leading cause of mortality of patients with type 2 diabetes mellitus, and both coronary artery disease (CAD) and diabetes mellitus are associated with inflammation. Emerging evidence suggests a relationship of the monocyte to high-density lipoprotein cholesterol ratio (MHR) with the incidence and severity of CAD. The aim of the present study was to examine the association of MHR with CAD in patients with type 2 diabetes mellitus. A total of 458 consecutive individuals were enrolled, comprising 178 type 2 diabetic patients, 124 type 2 diabetes with CAD, and 156 healthy volunteers as the controls. A multivariable logistic regression model was used to evaluate the relationship between the MHR and CAD in type 2 diabetes, and the receiver operating characteristic (ROC) curve of MHR was used for predicting the presence of CAD in type 2 diabetic patients. Values of MHR were significantly higher in type 2 diabetic patients with CAD compared with those without CAD and the control group. Moreover, multivariate logistic regression analysis showed that MHR was an independent predictor of the presence of CAD in type 2 diabetic patients (OR = 1.361, 95% CI 1.245 - 1.487, p < 0.0001). Based on the receiver operating characteristic (ROC) curve, the cutoff value of MHR (> 8.2) in predicting the presence of CAD in type 2 diabetic patients yields a sensitivity and specificity of 83.74% and 62.15%, respectively, with an area under the curve of 0.795 (95% CI: 0.745 - 0.840). The MHR is strongly associated with CAD in type 2 diabetes and might be a potential biomarker to predict the presence of CAD in type 2 diabetic patients.
Plaque imaging with CT—a comprehensive review on coronary CT angiography based risk assessment
Kolossváry, Márton; Szilveszter, Bálint; Merkely, Béla
2017-01-01
CT based technologies have evolved considerably in recent years. Coronary CT angiography (CTA) provides robust assessment of coronary artery disease (CAD). Early coronary CTA imaging—as a gate-keeper of invasive angiography—has focused on the presence of obstructive stenosis. Coronary CTA is currently the only non-invasive imaging modality for the evaluation of non-obstructive CAD, which has been shown to contribute to adverse cardiac events. Importantly, improved spatial resolution of CT scanners and novel image reconstruction algorithms enable the quantification and characterization of atherosclerotic plaques. State-of-the-art CT imaging can therefore reliably assess the extent of CAD and differentiate between various plaque features. Recent studies have demonstrated the incremental prognostic value of adverse plaque features over luminal stenosis. Comprehensive coronary plaque assessment holds potential to significantly improve individual risk assessment incorporating adverse plaque characteristics, the extent and severity of atherosclerotic plaque burden. As a result, several coronary CTA based composite risk scores have been proposed recently to determine patients at high risk for adverse events. Coronary CTA became a promising modality for the evaluation of functional significance of coronary lesions using CT derived fractional flow reserve (FFR-CT) and/or rest/dynamic myocardial CT perfusion. This could lead to substantial reduction in unnecessary invasive catheterization procedures and provide information on ischemic burden of CAD. Discordance between the degree of stenosis and ischemia has been recognized in clinical landmark trials using invasive FFR. Both lesion stenosis and composition are possibly related to myocardial ischemia. The evaluation of lesion-specific ischemia using combined functional and morphological plaque information could ultimately improve the diagnostic performance of CTA and thus patient care. In this review we aimed to summarize current evidence on comprehensive coronary artery plaque assessment using coronary CTA. PMID:29255692
Establishing CAD/CAM in Preclinical Dental Education: Evaluation of a Hands-On Module.
Schwindling, Franz Sebastian; Deisenhofer, Ulrich Karl; Porsche, Monika; Rammelsberg, Peter; Kappel, Stefanie; Stober, Thomas
2015-10-01
The aim of this study was to evaluate a hands-on computer-assisted design/computer-assisted manufacture (CAD/CAM) module in a preclinical dental course in restorative dentistry. A controlled trial was conducted by dividing a class of 56 third-year dental students in Germany into study and control groups; allocation to the two groups depended on student schedules. Prior information about CAD/CAM-based restorations was provided for all students by means of lectures, preparation exercises, and production of gypsum casts of prepared resin teeth. The study group (32 students) then participated in a hands-on CAD/CAM module in small groups, digitizing their casts and designing zirconia frameworks for single crowns. The digitization process was introduced to the control group (24 students) solely by means of a video-supported lecture. To assess the knowledge gained, a 20-question written examination was administered; 48 students took the exam. The results were analyzed with Student's t-tests at a significance level of 0.05. The results on the examination showed a significant difference between the two groups: the mean scores were 16.8 (SD 1.7, range 13-19) for the study group and 12.5 (SD 3, range 4-18) for the control group. After the control group had also experienced the hands-on module, a total of 48 students from both groups completed a questionnaire with 13 rating-scale and three open-ended questions evaluating the module. Those results showed that the module was highly regarded by the students. This study supports the idea that small-group hands-on courses are helpful for instruction in digital restoration design. These students' knowledge gained and satisfaction seemed to justify the time, effort, and equipment needed.
Is pseudoexfoliation syndrome associated with coronary artery disease?
Emiroglu, Mehmet Yunus; Coskun, Erol; Karapinar, Hekim; Capkın, Musa; Kaya, Zekeriya; Kaya, Hasan; Akcakoyun, Mustafa; Kargin, Ramazan; Simsek, Zeki; Acar, Göksel; Aung, Soe Moe; Pala, Selcuk; Özdemir, Burak; Esen, Ali Metin; Kırma, Cevat
2010-01-01
Background: Pseudoexfoliation syndrome (PEX) is recognised by chronic deposition of abnormal pseudoexfoliation material on anterior segment structures of the eye, especially the anterior lens capsule. In recent years, several studies have shown the presence of vascular, cardiac and other organ pseudoexfoliative material in patients with ocular pseudoexfoliation. Aims: The purpose of this study is to determine whether an association exists between ocular pseudoexfoliation and coronary artery disease, aortic aneurysms and peripheric vascular disease. Patients and Methods: 490 patients who underwent coronary angiography (CAG) at Kosuyolu Cardiovascula Research and Training Hospital were included in the study. Patients were evaluated for conventional risk factors such as age, sex, family history, hypertension, diabetes, dislipidemia and smoking. Detailed eye examinations including evaluation of lens were done in all patients. The presence of PEX material in the anterior segment was best appreciated by slit lamp after pupillary dilation. The patients were divided into two groups according to the presence of PEX, and compared for the presence of CAD and other risk factors. Results: CAD was present in 387 patients. 103 patients had normal coronary angiography. 20 (5.2 %) of CAD patients and 4 (3.9%) of normal CAG patients were found to have PEX (p>0.05). There was no significant relationship between CAD and the presence of PEX (p>0.05). When patients were grouped according to the presence of PEX, only age was significantly different between the two groups (r: 0.25, p<0.001). Conclusion: There is no significant relationship between the presence of PEX and CAD. Further studies in larger scales with elderly population may be more valuable. PMID:22558552
Zhang, Lijun; Song, Xiantao; Dong, Li; Li, Jianan; Dou, Ruiyu; Fan, Zhanming; An, Jing; Li, Debiao
2018-04-30
The purpose of the work was to evaluate the incremental diagnostic value of free-breathing, contrast-enhanced, whole-heart, 3 T cardiovascular magnetic resonance coronary angiography (CE-MRCA) to stress/rest myocardial perfusion imaging (MPI) and late gadolinium enhancement (LGE) imaging for detecting coronary artery disease (CAD). Fifty-one patients with suspected CAD underwent a comprehensive cardiovascular magnetic resonance (CMR) examination (CE-MRCA, MPI, and LGE). The additive diagnostic value of MRCA to MPI and LGE was evaluated using invasive x-ray coronary angiography (XA) as the standard for defining functionally significant CAD (≥ 50% stenosis in vessels > 2 mm in diameter). 90.2% (46/51) patients (54.0 ± 11.5 years; 71.7% men) completed CE-MRCA successfully. On per-patient basis, compared to MPI/LGE alone or MPI alone, the addition of MRCA resulted in higher sensitivity (100% vs. 76.5%, p < 0.01), no change in specificity (58.3% vs. 66.7%, p = 0.6), and higher accuracy (89.1% vs 73.9%, p < 0.01) for CAD detection (prevalence = 73.9%). Compared to LGE alone, the addition of CE-MRCA resulted in higher sensitivity (97.1% vs. 41.2%, p < 0.01), inferior specificity (83.3% vs. 91.7%, p = 0.02), and higher diagnostic accuracy (93.5% vs. 54.3%, p < 0.01). The inclusion of successful free-breathing, whole-heart, 3 T CE-MRCA significantly improved the sensitivity and diagnostic accuracy as compared to MPI and LGE alone for CAD detection.
Dental Diamond Rotary Instruments. Test and Evaluation
1983-09-01
Gov’t. agencies only; Critical Technology; Test and Evaluation; 19 NOV 1982. Other requests shall be referred to Dental Investigation Service, School of... DENTAL DIAMOND ROTARY INSTRUMENTS Test and Evaluation Cad D. Foster, Major, USAF, DC Joseph M. Powell, Colonel, USAF, DC John M. Young, Colonel, USAF...19 November 1982. Other requests for this document must be referred to the Dental Investig tion Service, USAF School of Aerospace Medicine. SUBJECT TO
Yilmaz, Burak; Alp, Gülce; Seidt, Jeremy; Johnston, William M; Vitter, Roger; McGlumphy, Edwin A
2018-01-06
The load-to-fracture performance of computer-assisted design and computer-assisted manufacturing (CAD-CAM) high-density polymer (HDP) materials in cantilevers is unknown. The purposes of this in vitro study were to evaluate the load-to-fracture performance of CAD-CAM-fabricated HDPs and to compare that with performance of autopolymerized and injection-molded acrylic resins. Specimens from 8 different brands of CAD-CAM HDPs, including Brylic Solid (BS); Brylic Gradient (BG); AnaxCAD Temp EZ (AE); AnaxCAD Temp Plus (AP); Zirkonzahn Temp Basic (Z); GDS Tempo-CAD (GD); Polident (Po); Merz M-PM-Disc (MAT); an autopolymerized acrylic resin, Imident (Conv) and an injection-molded acrylic resin, SR-IvoBase High Impact (Inj) were evaluated for load-to-fracture analysis (n=5). CAD-CAM specimens were milled from poly(methyl methacrylate) (PMMA) blocks measuring 7 mm in buccolingual width, 8 mm in occlusocervical thickness, and 30 mm in length. A wax pattern was prepared in the same dimensions used for CAD-CAM specimens, flasked, and boiled out. Autopolymerizing acrylic resin was packed and polymerized in a pressure container for 30 minutes. An identical wax pattern was flasked and boiled out, and premeasured capsules were injected (SR-IvoBase) and polymerized under hydraulic pressure for 35 minutes for the injection-molded PMMA. Specimens were thermocycled 5000 times (5°C to 55°C) and fixed to a universal testing machine to receive static loads on the 10-mm cantilever, vertically at a 1 mm/min crosshead speed until fracture occurred. Maximum load-to-fracture values were recorded. ANOVA was used to analyze the maximum force values. Significant differences among materials were analyzed by using the Ryan-Einot-Gabriel-Welsch multiple range test (α=.05). Statistically significant differences were found among load-to-fracture values of different HDPs (P<.001). GD and Po materials had significantly higher load-to-fracture values than other materials (P<.001), and no statistically significant differences were found between GD and Po. The lowest load-to-fracture values were observed for autopolymerized and BG materials, which were significantly lower than those of GD, Po, AE, AP, Z, MAT, Inj, and BS. The load-to-fracture value of autopolymerized acrylic resin was not significantly different from that of BG CAD-CAM polymer. GD and Po CAD-CAM materials had the highest load-to-fracture values. AE, AP, Z, MAT, and BS CAD-CAM polymers and injection-molded acrylic resin had similar load-to-fracture values, which were higher than those of BG and autopolymerized acrylic resin. Autopolymerized acrylic resin load-to-fracture value was similar to that of BG CAD-CAM polymer, which is colored in a gradient pattern. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Kumpatla, Satyavani; Karuppiah, Kirubakaran; Immaneni, Sathyamurthy; Muthukumaran, Parthiban; Krishnan, Jayanthi; Narayanamoorthy, Srinivasan Kanthallu; Viswanathan, Vijay
2014-01-01
Background & objectives: The association between adiponectin and risk of cardiovascular disease is well known. The aim of the present study was to evaluate adiponectin and certain inflammatory markers and to determine the correlations between them in angiographically proven coronary artery disease (CAD) in subjects with and without diabetes. Methods: A total of 180 subjects who underwent coronary angiography for symptoms suggestive of CAD were categorised into groups based on their diabetes and/or CAD status: group1 (non-diabetic non-CAD); group2 (non-diabetic CAD); group3 (diabetic non-CAD) and group4 (diabetic CAD). Adiponectin, tumour necrosis factor α (TNF-α) and soluble form of E-selectin (sE-selectin) were estimated using quantitative sandwich enzyme immunoassay and high sensitive C-reactive protein (hsCRP) by particle enhanced immunoturbidimetric method. Results: Adiponectin levels were significantly lower in subjects with either diabetes or CAD and were much lower in subjects who had both. hsCRP was elevated in CAD and diabetes but did not differ significantly between groups. sE-selectin and TNF-α levels were elevated in CAD. Adiponectin negatively correlated with age, glucose, sE-selectin, total and LDL cholesterol. hsCRP correlated with BMI, sE-selectin and urea. sE-selectin correlated with BMI, triglycerides and VLDL cholesterol, whereas TNF-α correlated with fasting plasma glucose. In the logistic regression analysis, adiponectin had a significant inverse association with CAD. sE-selectin and TNF-α also showed significant independent association with CAD. Interpretation & conclusions: Adiponectin and other inflammatory markers such as sE-selectin and TNF-α showed a significant association with CAD. Hence, early assessment of such markers can help to identify high risk patients, and to reduce the inflammatory component of diabetes and CAD. PMID:25109718
Sánchez-Osuna, María; Martínez-Escardó, Laura; Granados-Colomina, Carla; Martínez-Soler, Fina; Pascual-Guiral, Sònia; Iglesias-Guimarais, Victoria; Velasco, Roser; Plans, Gerard; Vidal, Noemi; Tortosa, Avelina; Barcia, Carlos; Bruna, Jordi; Yuste, Victor J.
2016-01-01
Background Glioblastoma (GBM) or grade IV astrocytoma is one of the most devastating human cancers. The loss of DFF40/CAD, the key endonuclease that triggers oligonucleosomal DNA fragmentation during apoptosis, has been linked to genomic instability and cell survival after radiation. Despite the near inevitability of GBM tumor recurrence after treatment, the relationship between DFF40/CAD and GBM remains unexplored. Methods We studied the apoptotic behavior of human GBM-derived cells after apoptotic insult. We analyzed caspase activation and the protein levels and subcellular localization of DFF40/CAD apoptotic endonuclease. DFF40/CAD was also evaluated in histological sections from astrocytic tumors and nontumoral human brain. Results We showed that GBM cells undergo incomplete apoptosis without generating oligonucleosomal DNA degradation despite the correct activation of executioner caspases. The major defect of GBM cells relied on the improper accumulation of DFF40/CAD at the nucleoplasmic subcellular compartment. Supporting this finding, DFF40/CAD overexpression allowed GBM cells to display oligonucleosomal DNA degradation after apoptotic challenge. Moreover, the analysis of histological slices from astrocytic tumors showed that DFF40/CAD immunoreactivity in tumoral GFAP-positive cells was markedly reduced when compared with nontumoral samples. Conclusions Our data highlight the low expression levels of DFF40/CAD and the absence of DNA laddering as common molecular traits in GBM. These findings could be of major importance for understanding the malignant behavior of remaining tumor cells after radiochemotherapy. PMID:26755073
Takaba, Masayuki; Tanaka, Shinpei; Ishiura, Yuichi; Baba, Kazuyoshi
2013-07-01
Recently, fixed dental prostheses (FDPs) with a hybrid structure of CAD/CAM porcelain crowns adhered to a CAD/CAM zirconia framework (PAZ) have been developed. The aim of this report was to describe the clinical application of a newly developed implant-supported FDP fabrication system, which uses PAZ, and to evaluate the outcome after a maximum application period of 36 months. Implants were placed in three patients with edentulous areas in either the maxilla or mandible. After the implant fixtures had successfully integrated with bone, gold-platinum alloy or zirconia custom abutments were first fabricated. Zirconia framework wax-up was performed on the custom abutments, and the CAD/CAM zirconia framework was prepared using the CAD/CAM system. Next, wax-up was performed on working models for porcelain crown fabrication, and CAD/CAM porcelain crowns were fabricated. The CAD/CAM zirconia frameworks and CAD/CAM porcelain crowns were bonded using adhesive resin cement, and the PAZ was cemented. Cementation of the implant superstructure improved the esthetics and masticatory efficiency in all patients. No undesirable outcomes, such as superstructure chipping, stomatognathic dysfunction, or periimplant bone resorption, were observed in any of the patients. PAZ may be a potential solution for ceramic-related clinical problems such as chipping and fracture and associated complicated repair procedures in implant-supported FDPs. © 2012 by the American College of Prosthodontists.
Al-mejrad, Lamya A.; Albarrag, Ahmed M.
2017-01-01
PURPOSE The goal of this study was to compare the adhesion of Candida albicans to the surfaces of CAD/CAM and conventionally fabricated complete denture bases. MATERIALS AND METHODS Twenty discs of acrylic resin poly (methyl methacrylate) were fabricated with CAD/CAM and conventional procedures (heat-polymerized acrylic resin). The specimens were divided into two groups: 10 discs were fabricated using the CAD/CAM procedure (Wieland Digital Denture Ivoclar Vivadent), and 10 discs were fabricated using a conventional flasking and pressure-pack technique. Candida colonization was performed on all the specimens using four Candida albicans isolates. The difference in Candida albicans adhesion on the discs was evaluated. The number of adherent yeast cells was calculated by the colony-forming units (CFU) and by Fluorescence microscopy. RESULTS There was a significant difference in the adhesion of Candida albicans to the complete denture bases created with CAD/CAM and the adhesion to those created with the conventional procedure. The CAD/CAM denture bases exhibited less adhesion of Candida albicans than did the denture bases created with the conventional procedure (P<.05). CONCLUSION The CAD/CAM procedure for fabricating complete dentures showed promising potential for reducing the adherence of Candida to the denture base surface. Clinical Implications. Complete dentures made with the CAD/CAM procedure might decrease the incidence of denture stomatitis compared with conventional dentures. PMID:29142649
Al-Fouzan, Afnan F; Al-Mejrad, Lamya A; Albarrag, Ahmed M
2017-10-01
The goal of this study was to compare the adhesion of Candida albicans to the surfaces of CAD/CAM and conventionally fabricated complete denture bases. Twenty discs of acrylic resin poly (methyl methacrylate) were fabricated with CAD/CAM and conventional procedures (heat-polymerized acrylic resin). The specimens were divided into two groups: 10 discs were fabricated using the CAD/CAM procedure (Wieland Digital Denture Ivoclar Vivadent), and 10 discs were fabricated using a conventional flasking and pressure-pack technique. Candida colonization was performed on all the specimens using four Candida albicans isolates. The difference in Candida albicans adhesion on the discs was evaluated. The number of adherent yeast cells was calculated by the colony-forming units (CFU) and by Fluorescence microscopy. There was a significant difference in the adhesion of Candida albicans to the complete denture bases created with CAD/CAM and the adhesion to those created with the conventional procedure. The CAD/CAM denture bases exhibited less adhesion of Candida albicans than did the denture bases created with the conventional procedure ( P <.05). The CAD/CAM procedure for fabricating complete dentures showed promising potential for reducing the adherence of Candida to the denture base surface. Clinical Implications. Complete dentures made with the CAD/CAM procedure might decrease the incidence of denture stomatitis compared with conventional dentures.
Fiechter, Michael; Ghadri, Jelena R; Wolfrum, Mathias; Kuest, Silke M; Pazhenkottil, Aju P; Nkoulou, Rene N; Herzog, Bernhard A; Gebhard, Cathérine; Fuchs, Tobias A; Gaemperli, Oliver; Kaufmann, Philipp A
2012-03-01
Low yield of invasive coronary angiography and unnecessary coronary interventions have been identified as key cost drivers in cardiology for evaluation of coronary artery disease (CAD). This has fuelled the search for noninvasive techniques providing comprehensive functional and anatomical information on coronary lesions. We have evaluated the impact of implementation of a novel hybrid cadmium-zinc-telluride (CZT)/64-slice CT camera into the daily clinical routine on downstream resource utilization. Sixty-two patients with known or suspected CAD were referred for same-day single-session hybrid evaluation with CZT myocardial perfusion imaging (MPI) and coronary CT angiography (CCTA). Hybrid MPI/CCTA images from the integrated CZT/CT camera served for decision-making towards conservative versus invasive management. Based on the hybrid images patients were classified into those with and those without matched findings. Matched findings were defined as the combination of MPI defect with a stenosis by CCTA in the coronary artery subtending the respective territory. All patients with normal MPI and CCTA as well as those with isolated MPI or CCTA finding or combined but unmatched findings were categorized as "no match". All 23 patients with a matched finding underwent invasive coronary angiography and 21 (91%) were revascularized. Of the 39 patients with no match, 5 (13%, p < 0.001 vs matched) underwent catheterization and 3 (8%, p < 0.001 vs matched) were revascularized. Cardiac hybrid imaging in CAD evaluation has a profound impact on patient management and may contribute to optimal downstream resource utilization.
Martins, José Luís; Adrega, Tiago; Santos, Luís; Afreixo, Vera; Viana, Jesus; Santos, José
2018-05-22
Behavioral and emotional factors are triggers of cardiovascular events (CVE). It remains uncertain whether football fans, particularly individuals with coronary artery disease (CAD), are at increased risk for CVE. To assess the effect of watching football matches in patients with known CAD on the incidence of ECV according to the match result. We prospectively evaluated 82 male football supporters, in 23 matches, with history of acute coronary syndrome during matches of the 2015/2016 season. Each individual was evaluated once and monitored with Holter on the day of their team's match and on the control day. Evaluated as the primary endpoint the composite of death, stroke, re-infarct angor or sustained arrhythmias. It was also evaluated as secondary endpoints, episodes of non-sustained supraventricular or ventricular dysrhythmia and mean heart rate (HR). The mean age was 61 ± 10 years. Compared with the control day, despite the significant increase of the HR (p <0.001), that was independent of the result (p> 0.97), the number of cardiovascular events was not different considering the result (p> 0.05). Moreover, the number of non-sustained episodes of supraventricular and ventricular dysrhythmia were not different stratifying according to the match result (p> 0.05). The match result was not associated with a different incidence of cardiovascular events in patients with past history of CAD, with ischemic and arrhythmic substrate, who watched football matches on television. Copyright © 2018 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.
Thomas, Dustin M; Branch, Kelley R; Cury, Ricardo C
2016-04-01
Coronary computed tomography angiography (CCTA) is a rapidly growing and powerful diagnostic test that offers a great deal of precision with respect to diagnosing coronary artery disease (CAD). Guideline statements for patients with stable ischemic heart disease have recommended CCTA for only a limited portion of intermediate-risk patients who have relative or absolute contraindications for exercise or vasodilator stress testing. The publication of two large, prospective randomized clinical trials, the Prospective Multicenter Imaging Study for Evaluation of Chest Pain and the Scottish Computed Tomography of the Heart Trial are likely to expand these indications. These new data from large trials, in addition to other studies, show that CCTA is highly sensitive for the detection of CAD, identifies high-risk patients for cardiac events based on extent or plaque morphology of CAD that would not be identified by other noninvasive means, and provides significantly greater diagnostic certainty for proper treatment, including referral for invasive coronary angiography with revascularization more appropriately. Superior diagnostic accuracy and prognostic data with CCTA, when compared with other functional stress tests, may result in a reduction in unnecessary downstream testing and cost savings. In addition, newer CCTA applications hold the promise of providing a complete evaluation of a patient's coronary anatomy as well as a per-vessel ischemic evaluation. This review focuses on the interval knowledge obtained from newer data on CCTA in patients with stable ischemic heart disease, primarily focusing on the contributions of the Prospective Multicenter Imaging Study for Evaluation of Chest Pain and the Scottish Computed Tomography of the Heart Trial.
Pop-Busui, Rodica; Lu, Jiang; Lopes, Neuza; Jones, Teresa L Z
2009-03-01
We evaluated the associations between glycemic therapies and prevalence of diabetic peripheral neuropathy (DPN) at baseline among participants in the Bypass Angioplasty Revascularization Investigation 2 Diabetes (BARI 2D) trial on medical and revascularization therapies for coronary artery disease (CAD) and on insulin-sensitizing vs. insulin-providing treatments for diabetes. A total of 2,368 patients with type 2 diabetes and CAD was evaluated. DPN was defined as clinical examination score >2 using the Michigan Neuropathy Screening Instrument (MNSI). DPN odds ratios across different groups of glycemic therapy were evaluated by multiple logistic regression adjusted for multiple covariates including age, sex, hemoglobin A1c (HbA1c), and diabetes duration. Fifty-one percent of BARI 2D subjects with valid baseline characteristics and MNSI scores had DPN. After adjusting for all variables, use of insulin was significantly associated with DPN (OR = 1.57, 95% CI: 1.15-2.13). Patients on sulfonylurea (SU) or combination of SU/metformin (Met)/thiazolidinediones (TZD) had marginally higher rates of DPN than the Met/TZD group. This cross-sectional study in a cohort of patients with type 2 diabetes and CAD showed association of insulin use with higher DPN prevalence, independent of disease duration, glycemic control, and other characteristics. The causality between a glycemic control strategy and DPN cannot be evaluated in this cross-sectional study, but continued assessment of DPN and randomized therapies in BARI 2D trial may provide further explanations on the development of DPN.
Dental students' preferences and performance in crown design: conventional wax-added versus CAD.
Douglas, R Duane; Hopp, Christa D; Augustin, Marcus A
2014-12-01
The purpose of this study was to evaluate dental students' perceptions of traditional waxing vs. computer-aided crown design and to determine the effectiveness of either technique through comparative grading of the final products. On one of twoidentical tooth preparations, second-year students at one dental school fabricated a wax pattern for a full contour crown; on the second tooth preparation, the same students designed and fabricated an all-ceramic crown using computer-aided design (CAD) and computer-aided manufacturing (CAM) technology. Projects were graded for occlusion and anatomic form by three faculty members. On completion of the projects, 100 percent of the students (n=50) completed an eight-question, five-point Likert scalesurvey, designed to assess their perceptions of and learning associated with the two design techniques. The average grades for the crown design projects were 78.3 (CAD) and 79.1 (wax design). The mean numbers of occlusal contacts were 3.8 (CAD) and 2.9(wax design), which was significantly higher for CAD (p=0.02). The survey results indicated that students enjoyed designing afull contour crown using CAD as compared to using conventional wax techniques and spent less time designing the crown using CAD. From a learning perspective, students felt that they learned more about position and the size/strength of occlusal contacts using CAD. However, students recognized that CAD technology has limits in terms of representing anatomic contours and excursive occlusion compared to conventional wax techniques. The results suggest that crown design using CAD could be considered as an adjunct to conventional wax-added techniques in preclinical fixed prosthodontic curricula.
Yang, R Y; Wang, S M; Sun, L; Liu, J M; Li, H X; Sui, X F; Wang, M; Xiu, H L; Wang, S; He, Q; Dong, J; Chen, W X
2015-10-01
Several recent studies have found an independent relationship between levels of plasma branched-chain amino acids (BCAAs) and risk factors for coronary artery disease (CAD); however, few studies have investigated the associations of BCAAs with CAD and the risk of cardiovascular events. Therefore, the aim of this study was to investigate the relationship between BCAAs and CAD. We studied 143 patients with CAD diagnosed by coronary angiography at Beijing Hospital (Beijing, China) during 2008-2011. Apparently healthy control individuals (n = 286) and the patients with CAD were matched (2:1 ratio) by age and gender. The healthy control individuals were selected at random from a set of subjects who attended an annual physical examination at the same hospital in 2011. Conditional logistic regression models were used to evaluate the associations between measured variables and CAD. After multivariate adjustment for traditional CAD risk factors, each one-standard-deviation increase in BCAA concentration was associated with an approximately twofold increase in the risk of CAD (odds ratio = 1.63, 95% confidence interval (CI): 1.21-2.20, P = 0.001). As compared with subjects in the lowest quartile of BCAA levels, the odds ratios (95% CIs) for CAD risk in subjects belonging to quartiles 2, 3, and 4 were 1.65 (0.75-3.61), 2.04 (0.92-4.53), and 3.86 (1.71-8.69), respectively (P trend = 0.01). Our results demonstrate that BCAAs are significantly related to CAD development. This relationship is independent of diabetes, hypertension, dyslipidemia, and body mass index. Copyright © 2015 Elsevier B.V. All rights reserved.
Braber, T L; Mosterd, A; Prakken, N H J; Doevendans, P A F M; Mali, W P Th M; Backx, F J G; Grobbee, D E; Rienks, R; Nathoe, H M; Bots, M L; Velthuis, B K
2015-02-01
More than 90 % of exercise-related cardiac arrests occur in men, predominantly those aged 45 years and older with coronary artery disease (CAD) as the main cause. The current sports medical evaluation (SME) of middle-aged recreational athletes consists of a medical history, physical examination, and resting and exercise electrocardiography. Coronary CT (CCT) provides a minimally invasive low radiation dose opportunity to image the coronary arteries. We present the study protocol of the Measuring Athlete's Risk of Cardiovascular events (MARC) study. MARC aims to assess the additional value of CCT to a routine SME in asymptomatic sportsmen ≥45 years without known CAD. MARC is a prospective study of 300 asymptomatic sportsmen ≥45 years who will undergo CCT if the SME does not reveal any cardiac abnormalities. The prevalence and determinants of CAD (coronary artery calcium score ≥100 Agatston Units (AU) or ≥50 % luminal stenosis) will be reported. The number needed to screen to prevent the occurrence of one cardiovascular event in the next 5 years, conditional to adequate treatment, will be estimated. We aim to determine the prevalence and severity of CAD and the additional value of CCT in asymptomatic middle-aged (≥45 years) sportsmen whose routine SME revealed no cardiac abnormalities.
van Schaik, T M; Jørstad, H T; Twickler, T B; Peters, R J G; Tijssen, J P G; Essink-Bot, M L; Fransen, M P
2017-07-01
To explore the association between health literacy and the risk of cardiovascular disease (CVD), and to assess the differential effects by health literacy level of a nurse-coordinated secondary prevention program (NCPP) in patients with coronary artery disease (CAD). Data were collected in two medical centres participating in the RESPONSE trial (Randomised Evaluation of Secondary Prevention by Outpatient Nurse SpEcialists). CVD risk profiles were assessed at baseline and 12-month follow-up using the Systematic Coronary Risk Evaluation (SCORE). Health literacy was assessed by the short Rapid Estimate of Adult Literacy in Medicine (REALM-D) and the Newest Vital Sign (NVS-D); self-reported health literacy was evaluated by the Set of Brief Screening Questions (SBSQ-D). Among 201 CAD patients, 18% exhibited reading difficulties, 52% had difficulty understanding and applying written information, and 5% scored low on self-reported health literacy. Patients with low NVS-D scores had a higher CVD risk [mean SCORE 5.2 (SD 4.8) versus 3.3 (SD 4.1), p < 0.01]. Nurse-coordinated care seemed to reduce CVD risk irrespective of health literacy levels without significant differences. Inadequate health literacy is prevalent in CAD patients in the Netherlands, and is associated with less favourable CVD risk profiles. Where many other forms of CVD prevention fail, nurse-coordinated care seems to be effective among patients with inadequate health literacy.
Computer-aided diagnosis with textural features for breast lesions in sonograms.
Chen, Dar-Ren; Huang, Yu-Len; Lin, Sheng-Hsiung
2011-04-01
Computer-aided diagnosis (CAD) systems provided second beneficial support reference and enhance the diagnostic accuracy. This paper was aimed to develop and evaluate a CAD with texture analysis in the classification of breast tumors for ultrasound images. The ultrasound (US) dataset evaluated in this study composed of 1020 sonograms of region of interest (ROI) subimages from 255 patients. Two-view sonogram (longitudinal and transverse views) and four different rectangular regions were utilized to analyze each tumor. Six practical textural features from the US images were performed to classify breast tumors as benign or malignant. However, the textural features always perform as a high dimensional vector; high dimensional vector is unfavorable to differentiate breast tumors in practice. The principal component analysis (PCA) was used to reduce the dimension of textural feature vector and then the image retrieval technique was performed to differentiate between benign and malignant tumors. In the experiments, all the cases were sampled with k-fold cross-validation (k=10) to evaluate the performance with receiver operating characteristic (ROC) curve. The area (A(Z)) under the ROC curve for the proposed CAD system with the specific textural features was 0.925±0.019. The classification ability for breast tumor with textural information is satisfactory. This system differentiates benign from malignant breast tumors with a good result and is therefore clinically useful to provide a second opinion. Copyright © 2010 Elsevier Ltd. All rights reserved.
Feng, Bin; Lin, Jin; Jin, Jin; Qian, Wenwei; Cao, Shiliang; Weng, Xisheng
2018-01-01
Although coronary artery revascularization therapies are effective for treating coronary artery disease (CAD), these patients may be more susceptible to adverse cardiac events during later non-cardiac surgeries. The purpose of this study is to evaluate post-operative 90-day complications of total joint arthroplasty (TJA) in CAD patients with a history of CAD and to study the risk factors for cardiac complications. We performed a retrospective analysis of TJA patients between 2005 and 2015 at our institute by summarizing the history of CAD, cardiac revascularization, and cardiac complications within 90 days after the operation. Multivariate logistic regression was performed to identify the factors that predicted cardiac complications within 90 days after the operation. A total of 4414 patients were included; of these, 64 underwent cardiac revascularization and 201 CAD patients underwent medical therapy other than revascularization. All the revascularization had history of myocardial infarction (MI). The rate of cardiac complications within 90 days for the CAD with revascularization was 18.7%, 18.4% for the CAD without revascularization, and 2.0% for the non-CAD group. A history of CAD and revascularization, bilateral TJA, general anesthesia, body mass index ≥30 kg/m 2 , and history of MI were associated with a higher risk of cardiac complications. Patients who underwent TJA within 2 years after cardiac revascularization had a significantly higher cardiac complication rate, and the risk decreased with time. There is an increased risk of cardiac complications within 90 days after the operation among TJA patients with a history of CAD. Revascularization cannot significantly reduce the risk of cardiac complications after TJA for CAD patients. However, the risk decreased as the interval between revascularization and TJA increased. Copyright © 2017 Elsevier Inc. All rights reserved.
Nossair, Shereen Ahmed; Aboushelib, Moustafa N; Morsi, Tarek Salah
2015-01-05
To evaluate the fracture mechanics of cemented versus fused CAD-on veneers on customized zirconia implant abutments. Forty-five identical customized CAD/CAM zirconia implant abutments (0.5 mm thick) were prepared and seated on short titanium implant abutments (Ti base). A second scan was made to fabricate 45 CAD-on veneers (IPS Empress CAD, A2). Fifteen CAD-on veneers were cemented on the zirconia abutments (Panavia F2.0). Another 15 were fused to the zirconia abutments using low-fusing glass, while manually layered veneers served as control (n = 15). The restorations were subjected to artificial aging (3.2 million cycles between 5 and 10 kg in a water bath at 37°C) before being axially loaded to failure. Fractured specimens were examined using scanning electron microscopy to detect fracture origin, location, and size of critical crack. Stress at failure was calculated using fractography principles (alpha = 0.05). Cemented CAD-on restorations demonstrated significantly higher (F = 72, p < 0.001) fracture load compared to fused CAD-on and manually layered restorations. Fractographic analysis of fractured specimens indicated that cemented CAD-on veneers failed due to radial cracks originating from the veneer/resin interface. Branching of the critical crack was observed in the bulk of the veneer. Fused CAD-on veneers demonstrated cohesive fracture originating at the thickest part of the veneer ceramic, while manually layered veneers failed due to interfacial fracture at the zirconia/veneer interface. Within the limitations of this study, cemented CAD-on veneers on customized zirconia implant abutments demonstrated higher fracture than fused and manually layered veneers. © 2014 by the American College of Prosthodontists.
Rotger, Margalida; Glass, Tracy R; Junier, Thomas; Lundgren, Jens; Neaton, James D; Poloni, Estella S; van 't Wout, Angélique B; Lubomirov, Rubin; Colombo, Sara; Martinez, Raquel; Rauch, Andri; Günthard, Huldrych F; Neuhaus, Jacqueline; Wentworth, Deborah; van Manen, Danielle; Gras, Luuk A; Schuitemaker, Hanneke; Albini, Laura; Torti, Carlo; Jacobson, Lisa P; Li, Xiuhong; Kingsley, Lawrence A; Carli, Federica; Guaraldi, Giovanni; Ford, Emily S; Sereti, Irini; Hadigan, Colleen; Martinez, Esteban; Arnedo, Mireia; Egaña-Gorroño, Lander; Gatell, Jose M; Law, Matthew; Bendall, Courtney; Petoumenos, Kathy; Rockstroh, Jürgen; Wasmuth, Jan-Christian; Kabamba, Kabeya; Delforge, Marc; De Wit, Stephane; Berger, Florian; Mauss, Stefan; de Paz Sierra, Mariana; Losso, Marcelo; Belloso, Waldo H; Leyes, Maria; Campins, Antoni; Mondi, Annalisa; De Luca, Andrea; Bernardino, Ignacio; Barriuso-Iglesias, Mónica; Torrecilla-Rodriguez, Ana; Gonzalez-Garcia, Juan; Arribas, José R; Fanti, Iuri; Gel, Silvia; Puig, Jordi; Negredo, Eugenia; Gutierrez, Mar; Domingo, Pere; Fischer, Julia; Fätkenheuer, Gerd; Alonso-Villaverde, Carlos; Macken, Alan; Woo, James; McGinty, Tara; Mallon, Patrick; Mangili, Alexandra; Skinner, Sally; Wanke, Christine A; Reiss, Peter; Weber, Rainer; Bucher, Heiner C; Fellay, Jacques; Telenti, Amalio; Tarr, Philip E
2013-07-01
Persons infected with human immunodeficiency virus (HIV) have increased rates of coronary artery disease (CAD). The relative contribution of genetic background, HIV-related factors, antiretroviral medications, and traditional risk factors to CAD has not been fully evaluated in the setting of HIV infection. In the general population, 23 common single-nucleotide polymorphisms (SNPs) were shown to be associated with CAD through genome-wide association analysis. Using the Metabochip, we genotyped 1875 HIV-positive, white individuals enrolled in 24 HIV observational studies, including 571 participants with a first CAD event during the 9-year study period and 1304 controls matched on sex and cohort. A genetic risk score built from 23 CAD-associated SNPs contributed significantly to CAD (P = 2.9 × 10(-4)). In the final multivariable model, participants with an unfavorable genetic background (top genetic score quartile) had a CAD odds ratio (OR) of 1.47 (95% confidence interval [CI], 1.05-2.04). This effect was similar to hypertension (OR = 1.36; 95% CI, 1.06-1.73), hypercholesterolemia (OR = 1.51; 95% CI, 1.16-1.96), diabetes (OR = 1.66; 95% CI, 1.10-2.49), ≥ 1 year lopinavir exposure (OR = 1.36; 95% CI, 1.06-1.73), and current abacavir treatment (OR = 1.56; 95% CI, 1.17-2.07). The effect of the genetic risk score was additive to the effect of nongenetic CAD risk factors, and did not change after adjustment for family history of CAD. In the setting of HIV infection, the effect of an unfavorable genetic background was similar to traditional CAD risk factors and certain adverse antiretroviral exposures. Genetic testing may provide prognostic information complementary to family history of CAD.
Aerodynamic Design of Complex Configurations Using Cartesian Methods and CAD Geometry
NASA Technical Reports Server (NTRS)
Nemec, Marian; Aftosmis, Michael J.; Pulliam, Thomas H.
2003-01-01
The objective for this paper is to present the development of an optimization capability for the Cartesian inviscid-flow analysis package of Aftosmis et al. We evaluate and characterize the following modules within the new optimization framework: (1) A component-based geometry parameterization approach using a CAD solid representation and the CAPRI interface. (2) The use of Cartesian methods in the development Optimization techniques using a genetic algorithm. The discussion and investigations focus on several real world problems of the optimization process. We examine the architectural issues associated with the deployment of a CAD-based design approach in a heterogeneous parallel computing environment that contains both CAD workstations and dedicated compute nodes. In addition, we study the influence of noise on the performance of optimization techniques, and the overall efficiency of the optimization process for aerodynamic design of complex three-dimensional configurations. of automated optimization tools. rithm and a gradient-based algorithm.
Raghavendra, U; Gudigar, Anjan; Maithri, M; Gertych, Arkadiusz; Meiburger, Kristen M; Yeong, Chai Hong; Madla, Chakri; Kongmebhol, Pailin; Molinari, Filippo; Ng, Kwan Hoong; Acharya, U Rajendra
2018-04-01
Ultrasound imaging is one of the most common visualizing tools used by radiologists to identify the location of thyroid nodules. However, visual assessment of nodules is difficult and often affected by inter- and intra-observer variabilities. Thus, a computer-aided diagnosis (CAD) system can be helpful to cross-verify the severity of nodules. This paper proposes a new CAD system to characterize thyroid nodules using optimized multi-level elongated quinary patterns. In this study, higher order spectral (HOS) entropy features extracted from these patterns appropriately distinguished benign and malignant nodules under particle swarm optimization (PSO) and support vector machine (SVM) frameworks. Our CAD algorithm achieved a maximum accuracy of 97.71% and 97.01% in private and public datasets respectively. The evaluation of this CAD system on both private and public datasets confirmed its effectiveness as a secondary tool in assisting radiological findings. Copyright © 2018 Elsevier Ltd. All rights reserved.
Lanktree, Matthew B; Hegele, Robert A
2009-02-26
Despite the recent success of genome-wide association studies (GWASs) in identifying loci consistently associated with coronary artery disease (CAD), a large proportion of the genetic components of CAD and its metabolic risk factors, including plasma lipids, type 2 diabetes and body mass index, remain unattributed. Gene-gene and gene-environment interactions might produce a meaningful improvement in quantification of the genetic determinants of CAD. Testing for gene-gene and gene-environment interactions is thus a new frontier for large-scale GWASs of CAD. There are several anecdotal examples of monogenic susceptibility to CAD in which the phenotype was worsened by an adverse environment. In addition, small-scale candidate gene association studies with functional hypotheses have identified gene-environment interactions. For future evaluation of gene-gene and gene-environment interactions to achieve the same success as the single gene associations reported in recent GWASs, it will be important to pre-specify agreed standards of study design and statistical power, environmental exposure measurement, phenomic characterization and analytical strategies. Here we discuss these issues, particularly in relation to the investigation and potential clinical utility of gene-gene and gene-environment interactions in CAD.
Cardiovascular Risk Assessment and Management in Prerenal Transplantation Candidates.
Lindley, Eric M; Hall, Amanda K; Hess, Jordan; Abraham, Jo; Smith, Brigham; Hopkins, Paul N; Shihab, Fuad; Welt, Frederick; Owan, Theophilus; Fang, James C
2016-01-01
Cardiovascular (CV) assessment in prerenal transplant patients varies by center. Current guidelines recommend stress testing for candidates if ≥ 3 CV risk factors exist. We evaluated the CV assessment and management in 685 patients referred for kidney transplant over a 7-year period. All patients had CV risk factors, and the most common cause of end-stage renal disease was diabetes. Thirty-three percent (n = 229) underwent coronary angiography. The sensitivity of stress testing to detect obstructive coronary artery disease (CAD) was poor (0.26). Patients who had no CAD, nonobstructive CAD, or CAD with intervention had significantly higher event-free survival compared with patients with obstructive CAD without intervention. There were no adverse clinical events (death, myocardial infarction, stroke, revascularization, and graft failure) within 30 days post-transplant in patients who had preoperative angiography (n = 77). Of the transplanted patients who did not have an angiogram (n = 289), there were 8 clinical events (6 myocardial infarctions) in the first 30 days. In conclusion, our results indicate that stress testing and usual risk factors were poor predictors of obstructive CAD and that revascularization may prove beneficial in these patients. Copyright © 2016 Elsevier Inc. All rights reserved.
A new data integration approach for AutoCAD and GIS
NASA Astrophysics Data System (ADS)
Ye, Hongmei; Li, Yuhong; Wang, Cheng; Li, Lijun
2006-10-01
GIS has its advantages both on spatial data analysis and management, particularly on the geometric and attributive information management, which has also attracted lots attentions among researchers around world. AutoCAD plays more and more important roles as one of the main data sources of GIS. Various work and achievements can be found in the related literature. However, the conventional data integration from AutoCAD to GIS is time-consuming, which also can cause the information loss both in the geometric aspects and the attributive aspects for a large system. It is necessary and urgent to sort out new approach and algorithm for the efficient high-quality data integration. In this paper, a novel data integration approach from AutoCAD to GIS will be introduced based on the spatial data mining technique through the data structure analysis both in the AutoCAD and GIS. A practicable algorithm for the data conversion from CAD to GIS will be given as well. By a designed evaluation scheme, the accuracy of the conversion both in the geometric and the attributive information will be demonstrated. Finally, the validity and feasibility of the new approach will be shown by an experimental analysis.
Automatic image database generation from CAD for 3D object recognition
NASA Astrophysics Data System (ADS)
Sardana, Harish K.; Daemi, Mohammad F.; Ibrahim, Mohammad K.
1993-06-01
The development and evaluation of Multiple-View 3-D object recognition systems is based on a large set of model images. Due to the various advantages of using CAD, it is becoming more and more practical to use existing CAD data in computer vision systems. Current PC- level CAD systems are capable of providing physical image modelling and rendering involving positional variations in cameras, light sources etc. We have formulated a modular scheme for automatic generation of various aspects (views) of the objects in a model based 3-D object recognition system. These views are generated at desired orientations on the unit Gaussian sphere. With a suitable network file sharing system (NFS), the images can directly be stored on a database located on a file server. This paper presents the image modelling solutions using CAD in relation to multiple-view approach. Our modular scheme for data conversion and automatic image database storage for such a system is discussed. We have used this approach in 3-D polyhedron recognition. An overview of the results, advantages and limitations of using CAD data and conclusions using such as scheme are also presented.
Wong, M S; Cheng, J C Y; Lo, K H
2005-04-01
The treatment effectiveness of the CAD/CAM method and the manual method in managing adolescent idiopathic scoliosis (AIS) was compared. Forty subjects were recruited with twenty subjects for each method. The clinical parameters namely Cobb's angle and apical vertebral rotation were evaluated at the pre-brace and the immediate in-brace visits. The results demonstrated that orthotic treatments rendered by the CAD/CAM method and the conventional manual method were effective in providing initial control of Cobb's angle. Significant decreases (p < 0.05) were found between the pre-brace and immediate in-brace visits for both methods. The mean reductions of Cobb's angle were 12.8 degrees (41.9%) for the CAD/CAM method and 9.8 degrees (32.1%) for the manual method. An initial control of the apical vertebral rotation was not shown in this study. In the comparison between the CAD/CAM method and the manual method, no significant difference was found in the control of Cobb's angle and apical vertebral rotation. The current study demonstrated that the CAD/CAM method can provide similar result in the initial stage of treatment as compared with the manual method.
Bittencourt, Marcio Sommer; Hulten, Edward; Polonsky, Tamar S; Hoffman, Udo; Nasir, Khurram; Abbara, Suhny; Di Carli, Marcelo; Blankstein, Ron
2016-07-19
The most appropriate score for evaluating the pretest probability of obstructive coronary artery disease (CAD) is unknown. We sought to compare the Diamond-Forrester (DF) score with the 2 CAD consortium scores recently recommended by the European Society of Cardiology. We included 2274 consecutive patients (age, 56±13 years; 57% male) without prior CAD referred for coronary computed tomographic angiography. Computed tomographic angiography findings were used to determine the presence or absence of obstructive CAD (≥50% stenosis). We compared the DF score with the 2 CAD consortium scores with respect to their ability to predict obstructive CAD and the potential implications of these scores on the downstream use of testing for CAD, as recommended by current guidelines. The DF score did not satisfactorily fit the data and resulted in a significant overestimation of the prevalence of obstructive CAD (P<0.001); the CAD consortium basic score had no significant lack of fitness; and the CAD consortium clinical provided adequate goodness of fit (P=0.39). The DF score had a lower discrimination for obstructive CAD, with an area under the receiver-operating characteristics curve of 0.713 versus 0.752 and 0.791 for the CAD consortium models (P<0.001 for both). Consequently, the use of the DF score was associated with fewer individuals being categorized as requiring no additional testing (8.3%) compared with the CAD consortium models (24.6% and 30.0%; P<0.001). The proportion of individuals with a high pretest probability was 18% with the DF and only 1.1% with the CAD consortium scores (P<0.001) CONCLUSIONS: Among contemporary patients referred for noninvasive testing, the DF risk score overestimates the risk of obstructive CAD. On the other hand, the CAD consortium scores offered improved goodness of fit and discrimination; thus, their use could decrease the need for noninvasive or invasive testing while increasing the yield of such tests. © 2016 American Heart Association, Inc.
Project DATA-TECH. 1990-91 Final Evaluation Profile. OREA Report.
ERIC Educational Resources Information Center
New York City Board of Education, Brooklyn, NY. Office of Research, Evaluation, and Assessment.
An evaluation was done of New York City Public Schools' Project DATA-TECH, which served limited English proficient high school students interested in computer-aided drafting (CAD) and cosmetology programs. The program served 190 students at Sara J. Hale High School in Brooklyn, of whom 89.5 percent were eligible for the Free Lunch Program and most…
Çakmak, Hüseyin Altuğ; Bayoğlu, Burcu; Durmaz, Eser; Can, Günay; Karadağ, Bilgehan; Cengiz, Müjgan; Vural, Vural Ali; Yüksel, Hüsniye
2015-03-01
Coronary artery disease (CAD), which develops from complex interactions between genetic and enviromental factors, is a leading cause of death worldwide. Based on genome-wide association studies (GWAS), the chromosomal region 9p21 has been identified as the most relevant locus presenting a strong association with CAD in different populations. The aim of the present study was to investigate the association of two SNPs on chromosome 9p21 on susceptibility to CAD and the effect of these SNPs along with cardiovascular risk factors on the severity of CAD in the Turkish population. This study had an observational case-control design. We genotyped 460 subjects, aged 30-65 years, to investigate the association of 2 SNPs (rs1333049, rs2383207) on chromosome 9p21 and CAD risk in Turkish population. Real-time polymerase chain reaction (RT-PCR) was used to analyze the 2 SNPs in CAD patients and healthy controls. The genotype and allelic variations of these SNPs with the severity of CAD was also assessed using semi-quantitative methods such as the Gensini score. Student's t test and multiple regression analysis were used for statistical analysis. The SNPs rs1333049 and rs2383207 were found to be associated with CAD with an adjusted OR of 1.81 (95% Cl 1.05-3.12) and 2.12 (95% CI 1.19-4.10) respectively. After adjustment of CAD risk factors such as smoking, family history of CAD and diabetes, the homozygous AA genotype for rs2383207 increased the CAD risk with an OR 3.69. Also a very strong association was found between rs1333049 and rs2383207 and Gensini scores representing the severity of CAD (p<0.001). The rs2383207 and rs1333049 SNPs on 9p21 chromosome were significantly associated with the risk and severity of CAD in the Turkish population.
Nakanishi, Rine; Berman, Daniel S.; Budoff, Matthew J.; Gransar, Heidi; Achenbach, Stephan; Al-Mallah, Mouaz; Andreini, Daniele; Cademartiri, Filippo; Callister, Tracy Q.; Chang, Hyuk-Jae; Cheng, Victor Y.; Chinnaiyan, Kavitha; Chow, Benjamin J.W.; Cury, Ricardo; Delago, Augustin; Hadamitzky, Martin; Hausleiter, Jörg; Feuchtner, Gudrun; Kim, Yong-Jin; Kaufmann, Philipp A.; Leipsic, Jonathon; Lin, Fay Y.; Maffei, Erica; Pontone, Gianluca; Raff, Gilbert; Shaw, Leslee J.; Villines, Todd C.; Dunning, Allison; Min, James K.
2015-01-01
Aims We evaluated coronary artery disease (CAD) extent, severity, and major adverse cardiac events (MACEs) in never, past, and current smokers undergoing coronary CT angiography (CCTA). Methods and results We evaluated 9456 patients (57.1 ± 12.3 years, 55.5% male) without known CAD (1588 current smokers; 2183 past smokers who quit ≥3 months before CCTA; and 5685 never smokers). By risk-adjusted Cox proportional-hazards models, we related smoking status to MACE (all-cause death or non-fatal myocardial infarction). We further performed 1:1:1 propensity matching for 1000 in each group evaluate event risk among individuals with similar age, gender, CAD risk factors, and symptom presentation. During a mean follow-up of 2.8 ± 1.9 years, 297 MACE occurred. Compared with never smokers, current and past smokers had greater atherosclerotic burden including extent of plaque defined as segments with any plaque (2.1 ± 2.8 vs. 2.6 ± 3.2 vs. 3.1 ± 3.3, P < 0.0001) and prevalence of obstructive CAD [1-vessel disease (VD): 10.6% vs. 14.9% vs. 15.2%, P < 0.001; 2-VD: 4.4% vs. 6.1% vs. 6.2%, P = 0.001; 3-VD: 3.1% vs. 5.2% vs. 4.3%, P < 0.001]. Compared with never smokers, current smokers experienced higher MACE risk [hazard ratio (HR) 1.9, 95% confidence interval (CI) 1.4–2.6, P < 0.001], while past smokers did not (HR 1.2, 95% CI 0.8–1.6, P = 0.35). Among matched individuals, current smokers had higher MACE risk (HR 2.6, 95% CI 1.6–4.2, P < 0.001), while past smokers did not (HR 1.3, 95% CI 0.7–2.4, P = 0.39). Similar findings were observed for risk of all-cause death. Conclusion Among patients without known CAD undergoing CCTA, current and past smokers had increased burden of atherosclerosis compared with never smokers; however, risk of MACE was heightened only in current smokers. PMID:25666322
Tarsitano, Achille; Battaglia, Salvatore; Crimi, Salvatore; Ciocca, Leonardo; Scotti, Roberto; Marchetti, Claudio
2016-07-01
The design and manufacture of patient-specific mandibular reconstruction plates, particularly in combination with cutting guides, has created many new opportunities for the planning and implementation of mandibular reconstruction. Although this surgical method is being used more widely and the outcomes appear to be improved, the question of the additional cost has to be discussed. To evaluate the cost generated by the management of this technology, we studied a cohort of patients treated for mandibular neoplasms. The population was divided into two groups of 20 patients each who were undergoing a 'traditional' freehand mandibular reconstruction or a computer-aided design/computer-aided manufacturing (CAD-CAM) mandibular reconstruction. Data concerning operation time, complications, and days of hospitalisation were used to evaluate costs related to the management of these patients. The mean operating time for the CAD-CAM group was 435 min, whereas that for the freehand group was 550.5 min. The total difference in terms of average time gain was 115.5 min. No microvascular complication occurred in the CAD-CAM group; two complications (10%) were observed in patients undergoing freehand reconstructions. The mean overall lengths of hospital stay were 13.8 days for the CAD-CAM group and 17 days for the freehand group. Finally, considering that the institutional cost per minute of theatre time is €30, the money saved as a result of the time gained was €3,450. This cost corresponds approximately to the total price of the CAD-CAM surgery. In conclusion, we believe that CAD-CAM technology for mandibular reconstruction will become a widely used reconstructive method and that its cost will be covered by gains in terms of surgical time, quality of reconstruction, and reduced complications. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Tilliet Le Dentu, H; Lancien, U; Sellal, O; Duteille, F; Perrot, P
2018-02-01
Pectus excavatum is the most common congenital chest malformation and is a common reason for consultation in plastic surgery. Our attitude is most often a filling of the depression with a custom-made silicone prosthesis. The objective of this work was to evaluate the interest of computer-aided design (CAD) of implants compared to the conventional plaster molds method. We have collected all the cases of custom-made silicone implants to treat funnel chests in our plastic surgery department. The quality of the results was evaluated by the patient, and in a blind manner by the surgical team using photographs and standardized surveys. The pre-operative delays, the operating time and length of hospital stays, the number of surgical recoveries, and the post-operative surgical outcomes were recorded. Between 1990 and 2016, we designed 29 silicone thoracic implants in our department. Before 2012, implants were made from plaster chest molds (n=13). After this date, implants were designed by CAD (n=16). Patients rated their results as "good" or "excellent" in 77% and 86% of cases respectively in the plaster and CAD groups. The surgical team's ratings for CAD implant reconstructions were better than in the plaster group: 8.17 versus 6.96 (P=0.001). CAD implants were significantly less detectable than the plaster group implants. The operating time was reduced in the CAO group: 60.2 compared to 74.7minutes in the plaster group (P=0.04), as was the length of hospitalization: 3.5 versus 5.3 days (P=0.01). There were no significant differences between the two groups in terms of post-operative complications. The management of pectus excavatum by a custom-made silicone implant is a minimally invasive method that provides good cosmetic results. The design of these implants is facilitated and qualitatively improved by CAD. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Effect of Crystallization Firing on Marginal Gap of CAD/CAM Fabricated Lithium Disilicate Crowns.
Gold, Steven A; Ferracane, Jack L; da Costa, Juliana
2018-01-01
To evaluate the marginal gaps of CAD/CAM (CEREC 3) produced crowns made from leucite-reinforced glass-ceramic (IPS Empress CAD) blocks (LG), and lithium-disilicate (IPS e.max CAD) blocks before (LD-B), and after (LD-A) crystallization firing. A human molar tooth (#19) was mounted with adjacent teeth on a typodont and prepared for a full-coverage ceramic crown. The typodont was assembled in the mannequin head to simulate clinical conditions. After tooth preparation 15 individual optical impressions were taken by the same operator using titanium dioxide powder and a CEREC 3 camera per manufacturer's instructions. One operator designed and machined the crowns in leucite-reinforced glass-ceramic blocks (n = 5) and lithium-disilicate blocks (n = 10) using the CEREC 3 system. The crowns were rigidly seated on the prepared tooth, and marginal gaps (μm) were measured with an optical microscope (500×) at 12 points, 3 on each of the M, B, D, and L surfaces of the leucite-reinforced glass-ceramic crowns and the lithium-disilicate crowns before and after crystallization firing. Results were analyzed by two-way ANOVA followed by a Tukey's post hoc multiple comparison test (α = 0.05). The overall mean marginal gaps (μm) for the crowns evaluated were: LG = 49.2 ± 5.5, LD-B = 42.9 ± 12.2, and LD-A = 57.2 ± 16.0. The marginal gaps for LG and LD-B were not significantly different, but both were significantly less than for LD-A. The type of ceramic material did not affect the marginal gap of CAD/CAM crowns. The crystallization firing process required for lithium-disilicate crowns resulted in a significant increase in marginal gap size, likely due to shrinkage of the ceramic during the crystallization process. The marginal gap of CAD/CAM-fabricated lithium disilicate crowns increases following crystallization firing. The marginal gap still remains within clinically acceptable parameters. © 2017 by the American College of Prosthodontists.
Escobedo, Jorge; Rana, Jamal S.; Lombardero, Manuel S.; Albert, Stewart G.; Davis, Andrew M.; Kennedy, Frank P.; Mooradian, Arshag D.; Robertson, David G.; Srinivas, V. S.; Gebhart, Suzanne S. P.
2010-01-01
OBJECTIVE: To evaluate the effect of prior duration of diabetes, glycated hemoglobin level at study entry, and microalbuminuria or macroalbuminuria on the extent and severity of coronary artery disease (CAD) and peripheral arterial disease. PATIENTS AND METHODS: We studied baseline characteristics of the 2368 participants of the BARI 2D (Bypass Angioplasty Revascularization Investigation 2 Diabetes) study, a randomized clinical trial that evaluates treatment efficacy for patients with type 2 diabetes and angiographically documented stable CAD. Patients were enrolled from January 1, 2001, through March 31, 2005. Peripheral arterial disease was ascertained by an ankle-brachial index (ABI) of 0.9 or less, and extent of CAD was measured by presence of multivessel disease, a left ventricular ejection fraction (LVEF) of less than 50%, and myocardial jeopardy index. RESULTS: Duration of diabetes of 20 or more years was associated with increased risk of ABI of 0.9 or less (odds ratio [OR], 1.54; 95% confidence interval [CI], 1.04-2.26), intermittent claudication (OR, 1.61; 95% CI, 1.10-2.35), and LVEF of less than 50% (OR, 2.03; 95% CI, 1.37-3.02). Microalbuminuria was associated with intermittent claudication (OR, 1.53; 95% CI, 1.16-2.02) and ABI of 0.9 or less (OR, 1.31; 95% CI, 0.98-1.75), whereas macroalbuminuria was associated with abnormal ABI, claudication, and LVEF of less than 50%. There was a significant association between diabetes duration and extent of CAD as manifested by number of coronary lesions, but no other significant associations were observed between duration of disease, glycated hemoglobin levels, or albumin-to-creatinine ratio and other manifestations of CAD. CONCLUSION: Duration of diabetes and microalbuminuria or macroalbuminuria are important predictors of severity of peripheral arterial disease and left ventricular dysfunction in a cohort of patients selected for the presence of CAD. PMID:20042560
Posadas-Sánchez, Rosalinda; López-Uribe, Ángel René; Posadas-Romero, Carlos; Pérez-Hernández, Nonanzit; Rodríguez-Pérez, José Manuel; Ocampo-Arcos, Wendy Angélica; Fragoso, José Manuel; Cardoso-Saldaña, Guillermo; Vargas-Alarcón, Gilberto
2017-10-01
The aim of this study was to evaluate the potential use of the I148M/PNPLA3 (rs738409) gene polymorphism as a susceptibility marker for premature coronary artery disease (pCAD) and/or cardiovascular risk factors in Mexican type 2 diabetes mellitus patients (T2DM). The polymorphism was genotyped by 5' exonuclease TaqMan assays in a group of 2572 subjects (1103 with pCAD and 1469 healthy controls) belonging to the Genetics of Atherosclerotic Disease (GEA) Mexican Study. Anthropometric and biochemical measurements were performed in all individuals. The association between the I148M/PNPLA3 (rs738409) gene polymorphism with pCAD and other metabolic and cardiovascular risk factors was evaluated using logistic regression analysis under different statistical approaches including dominant, recessive, heterozygous, additive, and co-dominant models. The polymorphism was not associated with pCAD in the whole group of participants, however, when patients and controls were divided into those with and without T2DM, under additive model, the polymorphism was associated with the presence of pCAD only in patients with T2DM (OR=1.20, 95% CI: 1.01-1.42, P add =0.042). On the other hand, under several models adjusted for age, gender, body mass index and T2DM, the polymorphism was associated with increased risk of fatty liver and elevated levels of alanine transaminase (ALT) in the whole group of pCAD patients and controls. In the control group, the polymorphism was associated with insulin resistance and coronary artery calcification (CAC) score≥10 under several models. The results suggest that the I148M/PNPLA3 (rs738409) polymorphism is associated with the presence of pCAD in T2DM patients and with some cardiometabolic parameters. The association detected with CAC in the control group indicates that this polymorphism could be a marker for subclinical atherosclerosis. Copyright © 2016 Elsevier GmbH. All rights reserved.
Hemal, Kshipra; Pagidipati, Neha J.; Coles, Adrian; Dolor, Rowena J.; Mark, Daniel B.; Pellikka, Patricia A.; Hoffmann, Udo; Litwin, Sheldon E.; Daubert, Melissa A.; Shah, Svati H.; Ariani, Kevin; Bullock-Palmer, Renee; Martinez, Beth; Lee, Kerry L.; Douglas, Pamela S.
2016-01-01
STRUCTURED ABSTRACT Objectives To determine whether presentation, risk assessment, testing choices, and results differ by sex in stable symptomatic outpatients with suspected coronary artery disease (CAD). Background Although established CAD presentations differ by sex, little is known about stable, suspected CAD. Methods Characteristics of 10,003 men and women in the Prospective Multicenter Imaging Study for Evaluation of Chest Pain (PROMISE) trial were compared using chi-square and Wilcoxon rank sum tests. Sex differences in test selection and predictors of test positivity were examined using logistic regression. Results Women were older (62.4 years vs. 59.0) and more likely to be hypertensive (66.6% vs. 63.2%), dyslipidemic (68.9% vs. 66.3%), and to have a family history of premature CAD (34.6% vs. 29.3) (all p-values<0.005). Women were less likely to smoke (45.6% vs. 57.0%; p<0.001), while diabetes prevalence was similar (21.8% vs. 21.0%; p=0.30). Chest pain was the primary symptom in 73.2% of women vs. 72.3% of men (p=0.30) and was characterized as “crushing/pressure/squeezing/tightness” in 52.5% of women vs. 46.2% of men (p<0.001). Compared to men, all risk scores characterized women as lower risk, and providers were more likely to characterize women as having low (<30%) pre-test probability for CAD (40.7% vs. 34.1%; p<0.001). Compared with men, women were more often referred to imaging tests (adjusted OR 1.21; 95% CI 1.01–1.44) than non-imaging tests. Women were less likely to have a positive test (9.7% vs. 15.1%; p<0.001). Although univariate predictors of test positivity were similar, in multivariable models, age, BMI, and Framingham risk score were predictive of a positive test in women, while Framingham and Diamond and Forrester risk scores were predictive in men. Conclusion Patient sex influences the entire diagnostic pathway for possible CAD, from baseline risk factors and presentation to noninvasive test outcomes. These differences highlight the need for sex-specific approaches to CAD evaluation. PMID:27017234
Mechanical properties and internal fit of 4 CAD-CAM block materials.
Goujat, Alexis; Abouelleil, Hazem; Colon, Pierre; Jeannin, Christophe; Pradelle, Nelly; Seux, Dominique; Grosgogeat, Brigitte
2018-03-01
Recent polymer-based computer-assisted design and computer-assisted manufacturing (CAD-CAM) materials have been commercialized for inlay restorations, a polymer-infiltrated ceramic-network (PICN) and composite resin nanoceramics. Little independent evidence regarding their mechanical properties exists. Internal adaptation is an important factor for the clinical success and longevity of a restoration, and data concerning this parameter for inlays made with these blocks are scarce. The purpose of this in vitro study was to evaluate and compare the mechanical properties (flexural strength, flexural modulus, Vickers hardness, fracture toughness) and the internal adaptation of these recent polymer-based blocks with a lithium disilicate glass-ceramic block. The materials tested in this study were a PICN material (Vita Enamic), 2 composite resin nanoceramics (Lava Ultimate; 3M ESPE and Cerasmart; GCDental Products), and a lithium disilicate glass-ceramic (IPS e.max CAD). Mechanical properties were evaluated according to ISO norm DIS 6872:2013. Bar-shaped specimens (18×3×3 mm) were prepared and submitted to a 3-point bend test using a universal testing machine at a cross-head speed of 0.5 mm/min. In addition, identical cavities were prepared in 60 human mandibular extracted molars (n=15) and optically scanned to receive mesioocclusodistal inlays milled with the 4 materials tested in a CEREC Inlab milling machine. The replica technique and a stereomicroscope (×20) were used to measure the internal fit of the inlays at 9 preselected locations. All data were statistically analyzed using 1-way ANOVA and the post hoc Tukey multiple comparison or Games-Howell test (α=.05). The mean flexural strength of the tested blocks ranged from 148.7 ±9.5 MPa (Vita Enamic) to 216.5 ±28.3 MPa (Cerasmart). The mean flexural modulus ranged from 23.3 ±6.4 GPa (Vita Enamic) to 52.8 ±10.5 GPa (IPS e.max CAD). The mean Vickers hardness ranged from 0.66 ±0.02 GPa (Cerasmart) to 5.98 ±0.69 GPa (IPS e.max CAD). The mean fracture toughness ranged from 1.2 ±0.17 MPa.m 1/2 (Cerasmart) to 1.8 ±0.29 MPa.m 1/2 (IPS e.max CAD). The values for internal discrepancy ranged from 119 ±55 μm to 234 ±51 μm. The mean internal discrepancy was significantly higher for Lava Ultimate (P<.05) than IPS e.max CAD and Cerasmart but not for Vita Enamic. The factor ''material'' was statistically significant in relation to the mechanical properties evaluated in this study (P<.05). The Pearson correlation was negative between the flexural strength results and the internal discrepancy of the materials tested (R 2 =0.941; P<.05). The mechanical properties of the CAD-CAM block materials tested were within the acceptable range for fabrication of single restorations according to the ISO standard for ceramics (ISO 6872:2008). IPS e.max CAD and Cerasmart were observed to have superior flexural strength and better internal fit. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Unkovskiy, Alexey; Spintzyk, Sebastian; Axmann, Detlef; Engel, Eva-Maria; Weber, Heiner; Huettig, Fabian
2017-11-10
The use of computer-aided design/computer-aided manufacturing (CAD/CAM) and additive manufacturing in maxillofacial prosthetics has been widely acknowledged. Rapid prototyping can be considered for manufacturing of auricular prostheses. Therefore, so-called prostheses replicas can be fabricated by digital means. The objective of this study was to identify a superior additive manufacturing method to fabricate auricular prosthesis replicas (APRs) within a digital workflow. Auricles of 23 healthy subjects (mean age of 37.8 years) were measured in vivo with respect to an anthropometrical protocol. Landmarks were volumized with fiducial balls for 3D scanning using a handheld structured light scanner. The 3D CAD dataset was postprocessed, and the same anthropometrical measurements were made in the CAD software with the digital lineal. Each CAD dataset was materialized using fused deposition modeling (FDM), selective laser sintering (SLS), and stereolithography (SL), constituting 53 APR samples. All distances between the landmarks were measured on the APRs. After the determination of the measurement error within the five data groups (in vivo, CAD, FDM, SLS, and SL), the mean values were compared using matched pairs method. To this, the in vivo and CAD dataset were set as references. Finally, the surface structure of the APRs was qualitatively evaluated with stereomicroscopy and profilometry to ascertain the level of skin detail reproduction. The anthropometrical approach showed drawbacks in measuring the protrusion of the ear's helix. The measurement error within all groups of measurements was calculated between 0.20 and 0.28 mm, implying a high reproducibility. The lowest mean differences of 53 produced APRs were found in FDM (0.43%) followed by SLS (0.54%) and SL (0.59%)--compared to in vivo, and again in FDM (0.20%) followed by SL (0.36%) and SLS (0.39%)--compared to CAD. None of these values exceed the threshold of clinical relevance (1.5%); however, the qualitative evaluation revealed slight shortcomings in skin reproduction for all methods: reproduction of skin details exceeding 0.192 mm in depth was feasible. FDM showed the superior dimensional accuracy and best skin surface reproduction. Moreover, digital acquisition and CAD postprocessing seem to play a more important role in the outcome than the additive manufacturing method used. © 2017 by the American College of Prosthodontists.
Video display engineering and optimization system
NASA Technical Reports Server (NTRS)
Larimer, James (Inventor)
1997-01-01
A video display engineering and optimization CAD simulation system for designing a LCD display integrates models of a display device circuit, electro-optics, surface geometry, and physiological optics to model the system performance of a display. This CAD system permits system performance and design trade-offs to be evaluated without constructing a physical prototype of the device. The systems includes a series of modules which permit analysis of design trade-offs in terms of their visual impact on a viewer looking at a display.
Zhang, Zutai; Tamaki, Yukimichi; Hotta, Yasuhiro; Miyazaki, Takashi
2006-07-01
For titanium casting, most commercial investments for titanium recommend casting at a low mold temperature to reduce oxidation. However, the thermal expansion values of the molds at low casting temperatures may be insufficient. The purpose of the current study was to investigate the possibility of obtaining accurate titanium crown casts using wax pattern fabricated by a CAD/CAM system with a non-expanded mold. Three types of experimental magnesia-based investments (A, B and C) were made and their properties were evaluated for dental use. Two kinds of wax patterns for full-coverage coping crowns (S-0: cement space of 0 microm; S-20: cement space of 20 microm) were fabricated using a commercial CAD/CAM system. A traditional method (TM) using inlay wax was performed for comparison. The investment for titanium casting was decided from the fundamental data of experimental investments. Titanium crowns were replaced on the stone die and the thickness of the cement layer was evaluated. There were no significant differences for the setting time and setting expansion among the experimental investments, but the aluminous cement content played a role in hardening and contracting the mold. The fit of the titanium crowns differed significantly between the TM and the CAD/CAM system. The ranges of thickness obtained from the TM, S-0 and S-20 were 20.78-357.88 microm, 25.12-107.46 microm and 17.84-58.92 microm, respectively. High quality titanium crown casting was obtained using a combination of wax patterns fabricated by a CAD/CAM system and a non-expanded MgO-based investment.
Acharya, U Rajendra; Sree, S Vinitha; Krishnan, M Muthu Rama; Molinari, Filippo; Zieleźnik, Witold; Bardales, Ricardo H; Witkowska, Agnieszka; Suri, Jasjit S
2014-02-01
Computer-aided diagnostic (CAD) techniques aid physicians in better diagnosis of diseases by extracting objective and accurate diagnostic information from medical data. Hashimoto thyroiditis is the most common type of inflammation of the thyroid gland. The inflammation changes the structure of the thyroid tissue, and these changes are reflected as echogenic changes on ultrasound images. In this work, we propose a novel CAD system (a class of systems called ThyroScan) that extracts textural features from a thyroid sonogram and uses them to aid in the detection of Hashimoto thyroiditis. In this paradigm, we extracted grayscale features based on stationary wavelet transform from 232 normal and 294 Hashimoto thyroiditis-affected thyroid ultrasound images obtained from a Polish population. Significant features were selected using a Student t test. The resulting feature vectors were used to build and evaluate the following 4 classifiers using a 10-fold stratified cross-validation technique: support vector machine, decision tree, fuzzy classifier, and K-nearest neighbor. Using 7 significant features that characterized the textural changes in the images, the fuzzy classifier had the highest classification accuracy of 84.6%, sensitivity of 82.8%, specificity of 87.0%, and a positive predictive value of 88.9%. The proposed ThyroScan CAD system uses novel features to noninvasively detect the presence of Hashimoto thyroiditis on ultrasound images. Compared to manual interpretations of ultrasound images, the CAD system offers a more objective interpretation of the nature of the thyroid. The preliminary results presented in this work indicate the possibility of using such a CAD system in a clinical setting after evaluating it with larger databases in multicenter clinical trials.
Implant-prosthetic rehabilitation of hemimaxillectomy defects with CAD/CAM suprastructures.
Mertens, Christian; de San Jose Gonzalez, Jose; Freudlsperger, Christian; Bodem, Jens; Krisam, Johannes; Hoffmann, Jürgen; Engel, Michael
2016-11-01
Patients with hemimaxillectomy defects after tumor surgery can alternatively be rehabilitated with dental obturators or microvascular flaps. When general medical or oncologic conditions do not permit microvascular surgery, dental obturators are the only solution, yet retention for edentulous patients is often poor. The aim of this study was to evaluate whether CAD/CAM suprastructures supported by implants placed in both residual alveolar ridges and contralateral zygomatic bone could enhance obturator stability and improve functional outcomes. Five edentulous patients with class IId hemimaxillectomy defects were included in the study. Implant-retained reconstructions were planned to support cross-arch CAD/CAM milled suprastructures. Patients had to rate their restorations on a 100-mm visual analogue scale before and after treatment. Additional evaluation was performed using the Oral Health Impact Profile (OHIP-EDENT) questionnaire. In the 5 patients, 7 conventional implants were placed in the remaining zygomatic bone and 16 in the remaining contralateral alveolar ridge. After 4 months of submerged healing, CAD/CAM suprastructures were fabricated that connected all respective implants with each other. All of the prosthetic restorations were removable and bar-retained. They all achieved good defect closure and showed significant improvements concerning general satisfaction (p = 0.0343), stability (p < 0.0001), ability to chew (p = 0.0077), esthetics (p = 0.0173) and foreign body sensation (p = 0.0207). According to the OHIP-EDENT questionnaire (p = 0.0036) the improvements were significant. During the observation period of 29.4 months, no mechanical or biological complications occurred. The CAD/CAM suprastructures improved retention in all treated patients without any complications. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Uzgur, Recep; Ercan, Ertuğrul; Uzgur, Zeynep; Çolak, Hakan; Yalçın, Muhammet; Özcan, Mutlu
2016-08-12
To evaluate the marginal and internal cement thicknesses of inlay restorations made of various CAD/CAM materials using 3D X-ray micro-computed tomography (micro-CT) technique. Caries-free extracted mandibular molars (N = 30) with similar size were randomly assigned to three groups (N = 10 per group). Mesio-occlusal-distal (MOD) cavities were prepared, and inlay restorations were obtained by milling out CAD/CAM materials namely, (a) IPS: monolithic lithium disilicate (control), (b) VE: polymer-infiltrated ceramic, and (c) CS: nano-ceramic using a CAM unit. Marginal and internal cement thicknesses were measured using 3D micro-CT. Data were analyzed using 1-way ANOVA and Tukey's tests (alpha = 0.05). The mean marginal and internal cement thickness were not significant in all inlay materials (p > 0.05). Mean marginal cement thickness (μm) was the lowest for the IPS group (67.54 ± 10.16) followed by VE (84.09 ± 3.94) and CS (95.18 ± 10.58) (p > 0.05). The internal cement thickness (μm) was the lowest in the CS group (54.85 ± 6.94) followed by IPS (60.58 ± 9.22) and VE (77.53 ± 12.13) (p > 0.05). Marginal and internal cement thicknesses of MOD inlays made of monolithic lithium disilicate, polymer-infiltrated ceramic, and nano-ceramic CAD/CAM materials were similar and all less than 100 μm, which could be considered clinically acceptable. MOD inlays made of different CAD/CAM materials presented similar cement thickness, less than 100 μm. © 2016 by the American College of Prosthodontists.
Toutouzas, Konstantinos; Benetos, Georgios; Koutagiar, Iosif; Barampoutis, Nikolaos; Mitropoulou, Fotini; Davlouros, Periklis; Sfikakis, Petros P; Alexopoulos, Dimitrios; Stefanadis, Christodoulos; Siores, Elias; Tousoulis, Dimitris
2017-07-01
Limited prospective data have been reported regarding the impact of carotid inflammation on cardiovascular events in patients with coronary artery disease (CAD). Microwave radiometry (MWR) is a noninvasive, simple method that has been used for evaluation of carotid artery temperature which, when increased, predicts 'inflamed' plaques with vulnerable characteristics. We prospectively tested the hypothesis that increased carotid artery temperature predicts future cerebro- and cardiovascular events in patients with CAD. Consecutive patients from 3 centers, with documented CAD by coronary angiography, were studied. In both carotid arteries, common carotid intima-media thickness and plaque thickness were evaluated by ultrasound. Temperature difference (ΔT), measured by MWR, was considered as the maximal temperature along the carotid artery minus the minimum; ΔT ≥0.90 °C was assigned as high. Major cardiovascular events (MACE, death, stroke, myocardial infarction or revascularization) were recorded during the following year. In total, 250 patients were studied; of them 40 patients (16%) had high ΔT values in both carotid arteries. MACEs occurred in 30% of patients having bilateral high ΔT versus 3.8% in the remaining patients (p<0.001). Bilateral high ΔT was independently associated with increased one-year MACE rate (HR = 6.32, 95% CI 2.42-16.53, p<0.001, by multivariate cox regression hazard model). The addition of ΔT information on a baseline model based on cardiovascular risk factors and extent of CAD significantly increased the prognostic value of the model (c-statistic increase 0.744 to 0.845, p dif = 0.05) CONCLUSIONS: Carotid inflammation, detected by MWR, has an incremental prognostic value in patients with documented CAD. Copyright © 2017 Elsevier B.V. All rights reserved.
Tiouririne, Mohamed; Dixon, Adam J; Mauldin, F William; Scalzo, David; Krishnaraj, Arun
2017-08-01
The aim of this study was to evaluate the imaging performance of a handheld ultrasound system and the accuracy of an automated lumbar spine computer-aided detection (CAD) algorithm in the spines of human subjects. This study was approved by the institutional review board of the University of Virginia. The authors designed a handheld ultrasound system with enhanced bone image quality and fully automated CAD of lumbar spine anatomy. The imaging performance was evaluated by imaging the lumbar spines of 68 volunteers with body mass index between 18.5 and 48 kg/m. The accuracy, sensitivity, and specificity of the lumbar spine CAD algorithm were assessed by comparing the algorithm's results to ground-truth segmentations of neuraxial anatomy provided by radiologists. The lumbar spine CAD algorithm detected the epidural space with a sensitivity of 94.2% (95% confidence interval [CI], 85.1%-98.1%) and a specificity of 85.5% (95% CI, 81.7%-88.6%) and measured its depth with an error of approximately ±0.5 cm compared with measurements obtained manually from the 2-dimensional ultrasound images. The spine midline was detected with a sensitivity of 93.9% (95% CI, 85.8%-97.7%) and specificity of 91.3% (95% CI, 83.6%-96.9%), and its lateral position within the ultrasound image was measured with an error of approximately ±0.3 cm. The bone enhancement imaging mode produced images with 5.1- to 10-fold enhanced bone contrast when compared with a comparable handheld ultrasound imaging system. The results of this study demonstrate the feasibility of CAD for assisting with real-time interpretation of ultrasound images of the lumbar spine at the bedside.
Lu, Michael T; Meyersohn, Nandini M; Mayrhofer, Thomas; Bittner, Daniel O; Emami, Hamed; Puchner, Stefan B; Foldyna, Borek; Mueller, Martin E; Hearne, Steven; Yang, Clifford; Achenbach, Stephan; Truong, Quynh A; Ghoshhajra, Brian B; Patel, Manesh R; Ferencik, Maros; Douglas, Pamela S; Hoffmann, Udo
2018-04-01
Purpose To assess concordance and relative prognostic utility between central core laboratory and local site interpretation for significant coronary artery disease (CAD) and cardiovascular events. Materials and Methods In the Prospective Multicenter Imaging Study for Evaluation of Chest Pain (PROMISE) trial, readers at 193 North American sites interpreted coronary computed tomographic (CT) angiography as part of the clinical evaluation of stable chest pain. Readers at a central core laboratory also interpreted CT angiography blinded to clinical data, site interpretation, and outcomes. Significant CAD was defined as stenosis greater than or equal to 50%; cardiovascular events were defined as a composite of cardiovascular death or myocardial infarction. Results In 4347 patients (51.8% women; mean age ± standard deviation, 60.4 years ± 8.2), core laboratory and site interpretations were discordant in 16% (683 of 4347), most commonly because of a finding of significant CAD by site but not by core laboratory interpretation (80%, 544 of 683). Overall, core laboratory interpretation resulted in 41% fewer patients being reported as having significant CAD (14%, 595 of 4347 vs 23%, 1000 of 4347; P < .001). Over a median follow-up period of 25 months, 1.3% (57 of 4347) sustained myocardial infarction or cardiovascular death. The C statistic for future myocardial infarction or cardiovascular death was 0.61 (95% confidence interval [CI]: 0.54, 0.68) for the core laboratory and 0.63 (95% CI: 0.56, 0.70) for the sites. Conclusion Compared with interpretation by readers at 193 North American sites, standardized core laboratory interpretation classified 41% fewer patients as having significant CAD. © RSNA, 2017 Online supplemental material is available for this article. Clinical trial registration no. NCT01174550.
Miszalski-Jamka, Tomasz; Kuntz-Hehner, Stefanie; Schmidt, Harald; Hammerstingl, Christoph; Tiemann, Klaus; Ghanem, Alexander; Troatz, Clemens; Lüderitz, Berndt; Omran, Heyder
2007-07-01
Myocardial contrast echocardiography (MCE) is a new imaging modality for diagnosing coronary artery disease (CAD). The aim of our study was to evaluate feasibility of qualitative myocardial contrast replenishment (RP) assessment during supine bicycle stress MCE and find out cutoff values for such analysis, which could allow accurate detection of CAD. Forty-four consecutive patients, scheduled for coronary angiography (CA) underwent supine bicycle stress two-dimensional echocardiography (2DE). During the same session, MCE was performed at peak stress and post stress. Ultrasound contrast agent (SonoVue) was administered in continuous mode using an infusion pump (BR-INF 100, Bracco Research). Seventeen-segment model of left ventricle was used in analysis. MCE was assessed off-line in terms of myocardial contrast opacification and RP. RP was evaluated on the basis of the number of cardiac cycles required to refill the segment with contrast after its prior destruction with high-power frames. Determination of cutoff values for RP assessment was performed by means of reference intervals and receiver operating characteristic analysis. Quantitative CA was carried out using CAAS system. MCE could be assessed in 42 patients. CA revealed CAD in 25 patients. Calculated cutoff values for RP-analysis (peak-stress RP >3 cardiac cycles and difference between peak stress and post stress RP >0 cardiac cycles) provided sensitive (88%) and accurate (88%) detection of CAD. Sensitivity and accuracy of 2DE were 76% and 79%, respectively. Qualitative RP-analysis based on the number of cardiac cycles required to refill myocardium with contrast is feasible during supine bicycle stress MCE and enables accurate detection of CAD.
Assessing operating characteristics of CAD algorithms in the absence of a gold standard
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roy Choudhury, Kingshuk; Paik, David S.; Yi, Chin A.
2010-04-15
Purpose: The authors examine potential bias when using a reference reader panel as ''gold standard'' for estimating operating characteristics of CAD algorithms for detecting lesions. As an alternative, the authors propose latent class analysis (LCA), which does not require an external gold standard to evaluate diagnostic accuracy. Methods: A binomial model for multiple reader detections using different diagnostic protocols was constructed, assuming conditional independence of readings given true lesion status. Operating characteristics of all protocols were estimated by maximum likelihood LCA. Reader panel and LCA based estimates were compared using data simulated from the binomial model for a range ofmore » operating characteristics. LCA was applied to 36 thin section thoracic computed tomography data sets from the Lung Image Database Consortium (LIDC): Free search markings of four radiologists were compared to markings from four different CAD assisted radiologists. For real data, bootstrap-based resampling methods, which accommodate dependence in reader detections, are proposed to test of hypotheses of differences between detection protocols. Results: In simulation studies, reader panel based sensitivity estimates had an average relative bias (ARB) of -23% to -27%, significantly higher (p-value <0.0001) than LCA (ARB -2% to -6%). Specificity was well estimated by both reader panel (ARB -0.6% to -0.5%) and LCA (ARB 1.4%-0.5%). Among 1145 lesion candidates LIDC considered, LCA estimated sensitivity of reference readers (55%) was significantly lower (p-value 0.006) than CAD assisted readers' (68%). Average false positives per patient for reference readers (0.95) was not significantly lower (p-value 0.28) than CAD assisted readers' (1.27). Conclusions: Whereas a gold standard based on a consensus of readers may substantially bias sensitivity estimates, LCA may be a significantly more accurate and consistent means for evaluating diagnostic accuracy.« less
A comparison of marginal fit between press-fabricated and CAD/CAM lithium disilicate crowns.
Carlile, Richard S; Owens, Wade H; Greenwood, William J; Guevara, Peter H
2018-01-01
The purpose of this study was to compare the marginal fit of press-fabricated lithium disilicate crowns with that of computer-aided design/computer-aided manufacturing (CAD/CAM) lithium disilicate crowns to determine if the fabrication method has an influence on marginal fit. The marginal fit of 25 pressed and 25 CAD/CAM crowns was measured using the replica technique. The sites measured were the mesial, distal, facial, and lingual margins. A microscope at 10× magnification was used to obtain the measurements. Each site was measured 4 times, and intraclass correlation coefficients were used to assess measurement errors. An unpaired t test was used to evaluate the differences between the 2 groups. Mean marginal gap measurements were greater for CAD/CAM crowns than for pressed crowns at all sites. Only the difference in mean gap at the facial margin was statistically significant (P < 0.001). Press-fabricated lithium disilicate crowns provided a better marginal fit than those fabricated by CAD/CAM, but both fabrication methods provided crowns with a clinically acceptable marginal fit.
Psychiatric Characteristics of the Cardiac Outpatients with Chest Pain.
Lee, Jea-Geun; Choi, Joon Hyouk; Kim, Song-Yi; Kim, Ki-Seok; Joo, Seung-Jae
2016-03-01
A cardiologist's evaluation of psychiatric symptoms in patients with chest pain is rare. This study aimed to determine the psychiatric characteristics of patients with and without coronary artery disease (CAD) and explore their relationship with the intensity of chest pain. Out of 139 consecutive patients referred to the cardiology outpatient department, 31 with atypical chest pain (heartburn, acid regurgitation, dyspnea, and palpitation) were excluded and 108 were enrolled for the present study. The enrolled patients underwent complete numerical rating scale of chest pain and the symptom checklist for minor psychiatric disorders at the time of first outpatient visit. The non-CAD group consisted of patients with a normal stress test, coronary computed tomography angiogram, or coronary angiogram, and the CAD group included those with an abnormal coronary angiogram. Nineteen patients (17.6%) were diagnosed with CAD. No differences in the psychiatric characteristics were observed between the groups. "Feeling tense", "self-reproach", and "trouble falling asleep" were more frequently observed in the non-CAD (p=0.007; p=0.046; p=0.044) group. In a multiple linear regression analysis with a stepwise selection, somatization without chest pain in the non-CAD group and hypochondriasis in the CAD group were linearly associated with the intensity of chest pain (β=0.108, R(2)=0.092, p=0.004; β= -0.525, R(2)=0.290, p=0.010). No differences in psychiatric characteristics were observed between the groups. The intensity of chest pain was linearly associated with somatization without chest pain in the non-CAD group and inversely linearly associated with hypochondriasis in the CAD group.
Pérez-Belmonte, Luis M.; Moreno-Santos, Inmaculada; Cabrera-Bueno, Fernando; Sánchez-Espín, Gemma; Castellano, Daniel; Such, Miguel; Crespo-Leiro, María G; Carrasco-Chinchilla, Fernando; Alonso-Pulpón, Luis; López-Garrido, Miguel; Ruiz-Salas, Amalio; Becerra-Muñoz, Víctor M.; Gómez-Doblas, Juan J.; de Teresa-Galván, Eduardo; Jiménez-Navarro, Manuel
2017-01-01
Objectives: Sterol regulatory element-binding proteins (SREBP) genes are crucial in lipid biosynthesis and cardiovascular homeostasis. Their expression in epicardial adipose tissue (EAT) and their influence in the development of coronary artery disease (CAD) and type-2 diabetes mellitus remain to be determined. The aim of our study was to evaluate the expression of SREBP genes in EAT in patients with CAD according to diabetes status and its association with clinical and biochemical data. Methods: SREBP-1 and SREBP-2 mRNA expression levels were measured in EAT from 49 patients with CAD (26 with diabetes) and 23 controls without CAD or diabetes. Results: Both SREBPs mRNA expression were significantly higher in patients with CAD and diabetes (p<0.001) and were identified as independent cardiovascular risk factor for coronary artery disease in patients with type-2 diabetes (SREBP-1: OR 1.7, 95%CI 1.1-2.5, p=0.02; SREBP-2: OR 1.6, 95%CI 1.2-3, p=0.02) and were independently associated with the presence of multivessel CAD, left main and anterior descending artery stenosis, and higher total and LDL cholesterol levels, and lower HDL cholesterol levels, in patients with CAD and diabetes. Conclusions: SREBP genes are expressed in EAT and were higher in CAD patients with diabetes than those patients without CAD or diabetes. SREBP expression was associated as cardiovascular risk factor for the severity of CAD and the poor lipid control. In this preliminary study we suggest the importance of EAT in the lipid metabolism and cardiovascular homeostasis for coronary atherosclerosis of patients with diabetes and highlight a future novel therapeutic target. PMID:28367087
Arbab-Zadeh, Armin; Miller, Julie M; Rochitte, Carlos E; Dewey, Marc; Niinuma, Hiroyuki; Gottlieb, Ilan; Paul, Narinder; Clouse, Melvin E.; Shapiro, Edward P.; Hoe, John; Lardo, Albert C.; Bush, David E.; de Roos, Albert; Cox, Christopher; Brinker, Jeffrey; Lima, Joăo A. C.
2012-01-01
Objectives Assess the impact of patient population characteristics on accuracy by CT angiography (CTA) to detect obstructive coronary artery disease (CAD). Background The ability of CTA to exclude obstructive CAD in patients of different pretest probabilities and in presence of coronary calcification remains uncertain. Methods For the CorE-64 study 371 patients underwent CTA and cardiac catheterization for the detection of obstructive CAD defined as 50% or greater luminal stenosis by quantitative coronary angiography (QCA). This analysis includes 80 initially excluded patients with a calcium score ≥ 600. Area under the receiver-operating-characteristics curve (AUC) was used to evaluate CTA diagnostic accuracy compared to QCA in patients according to calcium score and pretest probability of CAD. Results Analysis of patient-based quantitative CTA accuracy revealed an AUC of 0.93 (95% confidence interval [CI] 0.90-0.95). AUC remained 0.93 (0.90-0.96) after excluding patients with known CAD but decreased to 0.81 (0.71-0.89) in patients with calcium score ≥ 600 (p=0.077). While AUC were similar (0.93, 0.92, and 0.93, respectively) for patients with intermediate, high pretest probability for CAD, and known CAD, negative predictive values were different: 0.90, 0.83, and 0.50, respectively. Negative predictive values decreased from 0.93 to 0.75 for patients with calcium score < or ≥ 100, respectively (p= 0.053). Conclusions Both pretest probability for CAD and coronary calcium scoring should be considered before using CTA for excluding obstructive CAD. CTA is less effective for this purpose in patients with calcium score ≥ 600 and in patients with a high pretest probability for obstructive CAD. PMID:22261160
Pérez-Belmonte, Luis M; Moreno-Santos, Inmaculada; Cabrera-Bueno, Fernando; Sánchez-Espín, Gemma; Castellano, Daniel; Such, Miguel; Crespo-Leiro, María G; Carrasco-Chinchilla, Fernando; Alonso-Pulpón, Luis; López-Garrido, Miguel; Ruiz-Salas, Amalio; Becerra-Muñoz, Víctor M; Gómez-Doblas, Juan J; de Teresa-Galván, Eduardo; Jiménez-Navarro, Manuel
2017-01-01
Objectives: Sterol regulatory element-binding proteins (SREBP) genes are crucial in lipid biosynthesis and cardiovascular homeostasis. Their expression in epicardial adipose tissue (EAT) and their influence in the development of coronary artery disease (CAD) and type-2 diabetes mellitus remain to be determined. The aim of our study was to evaluate the expression of SREBP genes in EAT in patients with CAD according to diabetes status and its association with clinical and biochemical data. Methods: SREBP-1 and SREBP-2 mRNA expression levels were measured in EAT from 49 patients with CAD (26 with diabetes) and 23 controls without CAD or diabetes. Results : Both SREBPs mRNA expression were significantly higher in patients with CAD and diabetes (p<0.001) and were identified as independent cardiovascular risk factor for coronary artery disease in patients with type-2 diabetes (SREBP-1: OR 1.7, 95%CI 1.1-2.5, p=0.02; SREBP-2: OR 1.6, 95%CI 1.2-3, p=0.02) and were independently associated with the presence of multivessel CAD, left main and anterior descending artery stenosis, and higher total and LDL cholesterol levels, and lower HDL cholesterol levels, in patients with CAD and diabetes. Conclusions: SREBP genes are expressed in EAT and were higher in CAD patients with diabetes than those patients without CAD or diabetes. SREBP expression was associated as cardiovascular risk factor for the severity of CAD and the poor lipid control. In this preliminary study we suggest the importance of EAT in the lipid metabolism and cardiovascular homeostasis for coronary atherosclerosis of patients with diabetes and highlight a future novel therapeutic target.
Colonic polyps: application value of computer-aided detection in computed tomographic colonography.
Zhang, Hui-Mao; Guo, Wei; Liu, Gui-Feng; An, Dong-Hong; Gao, Shuo-Hui; Sun, Li-Bo; Yang, Hai-Shan
2011-02-01
Colonic polyps are frequently encountered in clinics. Computed tomographic colonography (CTC), as a painless and quick detection, has high values in clinics. In this study, we evaluated the application value of computer-aided detection (CAD) in CTC detection of colonic polyps in the Chinese population. CTC was performed with a GE 64-row multidetector computed tomography (MDCT) scanner. Data of 50 CTC patients (39 patients positive for at least one polyp of ≥ 0.5 cm in size and the other 11 patients negative by endoscopic detection) were retrospectively reviewed first without computer-aided detection (CAD) and then with CAD by four radiologists (two were experienced and another two inexperienced) blinded to colonoscopy findings. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of detected colonic polyps, as well as the areas under the ROC curves (Az value) with and without CAD were calculated. CAD increased the overall sensitivity, specificity, positive predictive value, negative predictive value and accuracy of the colonic polyps detected by experienced and inexperienced readers. The sensitivity in detecting small polyps (5 - 9 mm) with CAD in experienced and inexperienced readers increased from 82% and 44% to 93% and 82%, respectively (P > 0.05 and P < 0.001). With the use of CAD, the overall false positive rate and false negative rate for the detection of polyps by experienced and inexperienced readers decreased in different degrees. Among 13 sessile polyps not detected by CAD, two were ≥ 1.0 cm, eleven were 5 - 9 mm in diameter, and nine were flat-shaped lesions. The application of CAD in combination with CTC can increase the ability to detect colonic polyps, particularly for inexperienced readers. However, CAD is of limited value for the detection of flat polyps.
Muyoyeta, Monde; Maduskar, Pragnya; Moyo, Maureen; Kasese, Nkatya; Milimo, Deborah; Spooner, Rosanna; Kapata, Nathan; Hogeweg, Laurens; van Ginneken, Bram; Ayles, Helen
2014-01-01
To determine the sensitivity and specificity of a Computer Aided Diagnosis (CAD) program for scoring chest x-rays (CXRs) of presumptive tuberculosis (TB) patients compared to Xpert MTB/RIF (Xpert). Consecutive presumptive TB patients with a cough of any duration were offered digital CXR, and opt out HIV testing. CXRs were electronically scored as normal (CAD score ≤ 60) or abnormal (CAD score > 60) using a CAD program. All patients regardless of CAD score were requested to submit a spot sputum sample for testing with Xpert and a spot and morning sample for testing with LED Fluorescence Microscopy-(FM). Of 350 patients with evaluable data, 291 (83.1%) had an abnormal CXR score by CAD. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of CXR compared to Xpert were 100% (95%CI 96.2-100), 23.2% (95%CI 18.2-28.9), 33.0% (95%CI 27.6-38.7) and 100% (95% 93.9-100), respectively. The area under the receiver operator curve (AUC) for CAD was 0.71 (95%CI 0.66-0.77). CXR abnormality correlated with smear grade (r = 0.30, p<0.0001) and with Xpert CT(r = 0.37, p<0.0001). To our knowledge this is the first time that a CAD program for TB has been successfully tested in a real world setting. The study shows that the CAD program had high sensitivity but low specificity and PPV. The use of CAD with digital CXR has the potential to increase the use and availability of chest radiography in screening for TB where trained human resources are scarce.
Goeree, Ron; Chiva-Razavi, Sima; Gunda, Praveen; Graham, Christopher N; Miles, LaStella; Nikoglou, Efthalia; Jugl, Steffen M; Gladman, Dafna D
2018-02-01
The study evaluates the cost-effectiveness of secukinumab, a fully human monoclonal antibody that selectively neutralizes interleukin (IL)-17A, vs currently licensed biologic treatments in patients with active psoriatic arthritis (PsA) from a Canadian healthcare system perspective. A decision analytic semi-Markov model evaluated the cost-effectiveness of secukinumab 150 mg and 300 mg compared to subcutaneous biologics adalimumab, certolizumab pegol, etanercept, golimumab, and ustekinumab, and intravenous biologics infliximab and infliximab biosimilar in biologic-naive and biologic-experienced patients over a lifetime horizon. The response to treatments was evaluated after 12 weeks by PsA Response Criteria (PsARC) response rates. Non-responders or patients discontinuing initial-line of biologic treatment were allowed to switch to subsequent-line biologics. Model input parameters (Psoriasis Area Severity Index [PASI], Health Assessment Questionnaire [HAQ], withdrawal rates, costs, and resource use) were collected from clinical trials, published literature, and other Canadian sources. Benefits were expressed as quality-adjusted life years (QALYs). An annual discount rate of 5% was applied to costs and benefits. The robustness of the study findings were evaluated via sensitivity analyses. Biologic-naive patients treated with secukinumab achieved the highest number of QALYs (8.54) at the lowest cost (CAD 925,387) over a lifetime horizon vs all comparators. Secukinumab dominated all treatments, except for infliximab and its biosimilar, which achieved minimally more QALYs (8.58). However, infliximab and its biosimilar incurred more costs than secukinumab (infliximab: CAD 1,015,437; infliximab biosimilar: CAD 941,004), resulting in higher cost-effectiveness estimates relative to secukinumab. In the biologic-experienced population, secukinumab dominated all treatments as it generated more QALYs (8.89) at lower costs (CAD 954,692). Deterministic sensitivity analyses indicated the results were most sensitive to variation in PsARC response rates, change in HAQ, and utility values in both populations. Secukinumab is either dominant or cost-effective vs all licensed biologics for the treatment of active PsA in biologic-naive and biologic-experienced populations in Canada.
Chang, Yongjun; Paul, Anjan Kumar; Kim, Namkug; Baek, Jung Hwan; Choi, Young Jun; Ha, Eun Ju; Lee, Kang Dae; Lee, Hyoung Shin; Shin, DaeSeock; Kim, Nakyoung
2016-01-01
To develop a semiautomated computer-aided diagnosis (cad) system for thyroid cancer using two-dimensional ultrasound images that can be used to yield a second opinion in the clinic to differentiate malignant and benign lesions. A total of 118 ultrasound images that included axial and longitudinal images from patients with biopsy-confirmed malignant (n = 30) and benign (n = 29) nodules were collected. Thyroid cad software was developed to extract quantitative features from these images based on thyroid nodule segmentation in which adaptive diffusion flow for active contours was used. Various features, including histogram, intensity differences, elliptical fit, gray-level co-occurrence matrixes, and gray-level run-length matrixes, were evaluated for each region imaged. Based on these imaging features, a support vector machine (SVM) classifier was used to differentiate benign and malignant nodules. Leave-one-out cross-validation with sequential forward feature selection was performed to evaluate the overall accuracy of this method. Additionally, analyses with contingency tables and receiver operating characteristic (ROC) curves were performed to compare the performance of cad with visual inspection by expert radiologists based on established gold standards. Most univariate features for this proposed cad system attained accuracies that ranged from 78.0% to 83.1%. When optimal SVM parameters that were established using a grid search method with features that radiologists use for visual inspection were employed, the authors could attain rates of accuracy that ranged from 72.9% to 84.7%. Using leave-one-out cross-validation results in a multivariate analysis of various features, the highest accuracy achieved using the proposed cad system was 98.3%, whereas visual inspection by radiologists reached 94.9% accuracy. To obtain the highest accuracies, "axial ratio" and "max probability" in axial images were most frequently included in the optimal feature sets for the authors' proposed cad system, while "shape" and "calcification" in longitudinal images were most frequently included in the optimal feature sets for visual inspection by radiologists. The computed areas under curves in the ROC analysis were 0.986 and 0.979 for the proposed cad system and visual inspection by radiologists, respectively; no significant difference was detected between these groups. The use of thyroid cad to differentiate malignant from benign lesions shows accuracy similar to that obtained via visual inspection by radiologists. Thyroid cad might be considered a viable way to generate a second opinion for radiologists in clinical practice.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang, Yongjun; Paul, Anjan Kumar; Kim, Namkug, E-mail: namkugkim@gmail.com
Purpose: To develop a semiautomated computer-aided diagnosis (CAD) system for thyroid cancer using two-dimensional ultrasound images that can be used to yield a second opinion in the clinic to differentiate malignant and benign lesions. Methods: A total of 118 ultrasound images that included axial and longitudinal images from patients with biopsy-confirmed malignant (n = 30) and benign (n = 29) nodules were collected. Thyroid CAD software was developed to extract quantitative features from these images based on thyroid nodule segmentation in which adaptive diffusion flow for active contours was used. Various features, including histogram, intensity differences, elliptical fit, gray-level co-occurrencemore » matrixes, and gray-level run-length matrixes, were evaluated for each region imaged. Based on these imaging features, a support vector machine (SVM) classifier was used to differentiate benign and malignant nodules. Leave-one-out cross-validation with sequential forward feature selection was performed to evaluate the overall accuracy of this method. Additionally, analyses with contingency tables and receiver operating characteristic (ROC) curves were performed to compare the performance of CAD with visual inspection by expert radiologists based on established gold standards. Results: Most univariate features for this proposed CAD system attained accuracies that ranged from 78.0% to 83.1%. When optimal SVM parameters that were established using a grid search method with features that radiologists use for visual inspection were employed, the authors could attain rates of accuracy that ranged from 72.9% to 84.7%. Using leave-one-out cross-validation results in a multivariate analysis of various features, the highest accuracy achieved using the proposed CAD system was 98.3%, whereas visual inspection by radiologists reached 94.9% accuracy. To obtain the highest accuracies, “axial ratio” and “max probability” in axial images were most frequently included in the optimal feature sets for the authors’ proposed CAD system, while “shape” and “calcification” in longitudinal images were most frequently included in the optimal feature sets for visual inspection by radiologists. The computed areas under curves in the ROC analysis were 0.986 and 0.979 for the proposed CAD system and visual inspection by radiologists, respectively; no significant difference was detected between these groups. Conclusions: The use of thyroid CAD to differentiate malignant from benign lesions shows accuracy similar to that obtained via visual inspection by radiologists. Thyroid CAD might be considered a viable way to generate a second opinion for radiologists in clinical practice.« less
Kömürcüoğlu, Meltem Bektaş; Sağırkaya, Elçin; Tulga, Ayça
2017-12-01
To evaluate the effects of different surface treatments on the bond strength of novel CAD/CAM restorative materials to resin cement by four point bending test. The CAD/CAM materials under investigation were e.max CAD, Mark II, Lava Ultimate, and Enamic. A total of 400 bar specimens (4×1.2×12 mm) (n=10) milled from the CAD/CAM blocks underwent various pretreatments (no pretreatment (C), hydrofluoric acid (A), hydrofluoric acid + universal adhesive (Scotchbond) (AS), sandblasting (Sb), and sandblasting + universal adhesive (SbS)). The bars were luted end-to-end on the prepared surfaces with a dual curing adhesive resin cement (Variolink N, Ivoclar Vivadent) on the custom-made stainless steel mold. Ten test specimens for each treatment and material combination were performed with four point bending test method. Data were analyzed using ANOVA and Tukey's test. The surface treatment and type of CAD/CAM restorative material showed a significant effect on the four point bending strength (FPBS) ( P <.001). For LDC, AS surface treatment showed the highest FPBS results (100.31 ± 10.7 MPa) and the lowest values were obtained in RNC (23.63 ± 9.0 MPa) for control group. SEM analyses showed that the surface topography of CAD/CAM restorative materials was modified after treatments. The surface treatment of sandblasting or HF acid etching in combination with a universal adhesive containing MDP can be suggested for the adhesive cementation of the novel CAD/CAM restorative materials.
Philippova, Maria; Ivanov, Danila; Joshi, Manjunath B.; Kyriakakis, Emmanouil; Rupp, Katharina; Afonyushkin, Taras; Bochkov, Valery; Erne, Paul; Resink, Therese J.
2008-01-01
There is scant knowledge regarding how cell surface lipid-anchored T-cadherin (T-cad) transmits signals through the plasma membrane to its intracellular targets. This study aimed to identify membrane proteins colocalizing with atypical glycosylphosphatidylinositol (GPI)-anchored T-cad on the surface of endothelial cells and to evaluate their role as signaling adaptors for T-cad. Application of coimmunoprecipitation from endothelial cells expressing c-myc-tagged T-cad and high-performance liquid chromatography revealed putative association of T-cad with the following proteins: glucose-related protein GRP78, GABA-A receptor α1 subunit, integrin β3, and two hypothetical proteins, LOC124245 and FLJ32070. Association of Grp78 and integrin β3 with T-cad on the cell surface was confirmed by surface biotinylation and reciprocal immunoprecipitation and by confocal microscopy. Use of anti-Grp78 blocking antibodies, Grp78 small interfering RNA, and coexpression of constitutively active Akt demonstrated an essential role for surface Grp78 in T-cad-dependent survival signal transduction via Akt in endothelial cells. The findings herein are relevant in the context of both the identification of transmembrane signaling partners for GPI-anchored T-cad as well as the demonstration of a novel mechanism whereby Grp78 can influence endothelial cell survival as a cell surface signaling receptor rather than an intracellular chaperone. PMID:18411300
Dental Electric Handengines: Test and Evaluation.
1985-04-01
ADRD5 066 A DENTAL ELECTRIC HANDENGINES: TEST AND EVALUATION(U) j/ij SCHOOL OF AEROSPACE MEDICINE BROOKS AFB TX C D FOSTER ET AL. APR 85 USAFSAM-TR... DENTAL ELECTRIC HANDENGINES o Test and Evaluation In -- I Cad D. Foster, Major, USAF, DC Paul M. Callison, Master Sergeant, USAF Gerald F. McKinley...AFSC) Brooks Air Force Base, TX 78235-5301 85 7 15 057 NOTICES This final report was submitted by personnel of the Dental Investigation Service
South Asian ethnicity and cardiovascular risk: the known, the unknown, and the paradox.
Ahmed, Emad; El-Menyar, Ayman
2015-05-01
South Asians (SAs), in their countries or after migration, are at high risk of coronary artery disease (CAD) and mortality compared to other ethnic groups. It has been shown that >90% of CAD global risk could be attributed to 9 modifiable risk factors (RFs) worldwide. However, these conventional RFs may not fully explain this high risk of CAD among SAs. Therefore, attention has been directed toward nonconventional RFs. In this narrative review, we evaluate the conventional and emerging cardiovascular RFs characterizing SAs. These factors may explain the high morbidity and mortality among SAs. Further prospective studies are urgently needed to set algorithms for the optimal management of these RFs in high-risk populations like SAs. © The Author(s) 2014.
Rapid Analysis of Mass Distribution of Radiation Shielding
NASA Technical Reports Server (NTRS)
Zapp, Edward
2007-01-01
Radiation Shielding Evaluation Toolset (RADSET) is a computer program that rapidly calculates the spatial distribution of mass of an arbitrary structure for use in ray-tracing analysis of the radiation-shielding properties of the structure. RADSET was written to be used in conjunction with unmodified commercial computer-aided design (CAD) software that provides access to data on the structure and generates selected three-dimensional-appearing views of the structure. RADSET obtains raw geometric, material, and mass data on the structure from the CAD software. From these data, RADSET calculates the distribution(s) of the masses of specific materials about any user-specified point(s). The results of these mass-distribution calculations are imported back into the CAD computing environment, wherein the radiation-shielding calculations are performed.
Dantas, Roberto Nery; Assuncao, Antonildes Nascimento; Marques, Ismar Aguiar; Fahel, Mateus Guimaraes; Nomura, Cesar Higa; Avila, Luiz Francisco Rodrigues; Giorgi, Maria Clementina Pinto; Soares, Jose; Meneghetti, Jose Claudio; Parga, Jose Rodrigues
2018-06-01
Despite advances in non-invasive myocardial perfusion imaging (MPI) evaluation, computed tomography (CT) multiphase MPI protocols have not yet been compared with the highly accurate rubidium-82 positron emission tomography ( 82 RbPET) MPI. Thus, this study aimed to evaluate agreement between 82 RbPET and 320-detector row CT (320-CT) MPI using a multiphase protocol in suspected CAD patients. Forty-four patients referred for MPI evaluation were prospectively enrolled and underwent dipyridamole stress 82 RbPET and multiphase 320-CT MPI (five consecutive volumetric acquisitions during stress). Statistical analyses were performed using the R software. There was high agreement for recognizing summed stress scores ≥ 4 (kappa 0.77, 95% CI 0.55-0.98, p < 0.001) and moderate for detecting SDS ≥ 2 (kappa 0.51, 95% CI 0.23-0.80, p < 0.001). In a per segment analysis, agreement was high for the presence of perfusion defects during stress and rest (kappa 0.75 and 0.82, respectively) and was moderate for impairment severity (kappa 0.58 and 0.65, respectively). The 320-CT protocol was safe, with low radiation burden (9.3 ± 2.4 mSv). There was a significant agreement between dipyridamole stress 320-CT MPI and 82 RbPET MPI in the evaluation of suspected CAD patients of intermediate risk. The multiphase 320-CT MPI protocol was feasible, diagnostic and with relatively low radiation exposure. • Rubidium-82 PET and 320-MDCT can perform MPI studies for CAD investigation. • There is high agreement between rubidium-82 PET and 320-MDCT for MPI assessment. • Multiphase CT perfusion protocols are feasible and with low radiation. • Multiphase CT perfusion protocols can identify image artefacts.
Lee, Sang-Eun; Uhm, Jae-Sun; Kim, Jong-Youn; Pak, Hui-Nam; Lee, Moon-Hyoung; Joung, Boyoung
2015-07-01
Acute coronary lesions commonly trigger out-of-hospital cardiac arrest (OHCA). However, the prevalence of coronary artery disease (CAD) in Asian patients with OHCA and whether electrocardiogram (ECG) and other findings might predict acute myocardial infarction (AMI) have not been fully elucidated. Of 284 consecutive resuscitated OHCA patients seen between January 2006 and July 2013, we enrolled 135 patients who had undergone coronary evaluation. ECGs, echocardiography, and biomarkers were compared between patients with or without CAD. We included 135 consecutive patients aged 54 years (interquartile range 45-65) with sustained return of spontaneous circulation after OHCA between 2006 and 2012. Sixty six (45%) patients had CAD. The initial rhythm was shockable and non-shockable in 110 (81%) and 25 (19%) patients, respectively. ST-segment elevation predicted CAD with 42% sensitivity, 87% specificity, and 65% accuracy. ST elevation and/or regional wall motion abnormality (RWMA) showed 68% sensitivity, 52% specificity, and 70% accuracy in the prediction of CAD. Finally, a combination of ST elevation and/or RWMA and/or troponin T elevation predicted CAD with 94% sensitivity, 17% specificity, and 55% accuracy. In patients with OHCA without obvious non-cardiac causes, selection for coronary angiogram based on the combined criterion could detect 94% of CADs. However, compared with ECG only criteria, the combined criterion failed to improve diagnostic accuracy with a lower specificity.
Clinical use of a ceramide-based moisturizer for treating dogs with atopic dermatitis
Jung, Ji-young; Nam, Eui-hwa; Park, Seol-hee; Han, Seung-hee
2013-01-01
In humans, skin barrier dysfunction is thought to be responsible for enhanced penetration of allergens. Similar to conditions seen in humans, canine atopic dermatitis (CAD) is characterized by derangement of corneocytes and disorganization of intercellular lipids in the stratum corenum (SC) with decreased ceramide levels. This study was designed to evaluate the effects of a moisturizer containing ceramide on dogs with CAD. Dogs (n = 20, 3~8 years old) with mild to moderate clinical signs were recruited and applied a moisturizer containing ceramide for 4 weeks. Transepidermal water loss (TEWL), skin hydration, pruritus index for canine atopic dermatitis (PICAD) scores, and canine atopic dermatitis extent and severity index (CADESI) scores of all dogs were evaluated. Skin samples from five dogs were also examined with transmission electron microscopy (TEM) using ruthenium tetroxide. TEWL, PICAD, and CADESI values decreased (p < 0.05) and skin hydration increased dramatically over time (p < 0.05). Electron micrographs showed that the skin barrier of all five dogs was partially restored (p < 0.05). In conclusion, these results demonstrated that moisturizer containing ceramide was effective for treating skin barrier dysfunction and CAD symptoms. PMID:23814473
Polyarterial clustered recurrence of cervical artery dissection seems to be the rule.
Dittrich, R; Nassenstein, I; Bachmann, R; Maintz, D; Nabavi, D G; Heindel, W; Kuhlenbäumer, G; Ringelstein, E B
2007-07-10
Spontaneous cervical artery dissection (sCAD) in multiple neck arteries (polyarterial sCAD) is traditionally thought to represent a monophasic disorder suggesting nearly simultaneous occurrence of the various intramural hematomas. Its incidence ranges from 10 to 28%. The recurrence rate of sCAD in general over up to 8.6 years has been recorded to be 0 to 8%. To analyze more precisely the temporal and spatial neuroangiologic course of sCAD with particular focus on polyarterial manifestation. We prospectively investigated 36 consecutive patients with sCAD unexceptionally proven by MR imaging at 1.5 T. We reinvestigated these patients by two follow-up MR examinations. The first follow-up MR examination was performed after a mean of 16 +/- 13 days, and the last MR study after a mean of 7 +/- 2 months after the initial diagnosis. Systematic data evaluation of the 36 patients revealed the following phenomena of sCAD: 1) seemingly simultaneous polyarterial sCAD on the initial MRI scan (n = 2; 6%); 2) recurrent sCAD in one or several initially uninvolved cervical arteries during follow-up (n = 9; 25%). These latter sCAD occurred as an early polyarterial recurrent event within 1 to 4 weeks in 7 patients (19%), and as a delayed polyarterial recurrent event within 5 to 7 months in 2 patients (6%). Under a spatial perspective, sCAD recurrence took place in one additional cervical artery in 5 patients (14%), or in more than one previously uninvolved cervical artery in 4 patients (11%). All patients except one with sCAD recurrence remained asymptomatic or had local symptoms only. One patient experienced a significant clinical deterioration due to ischemic stroke with acute impairment of cerebral hemodynamics. During follow-up, patients received transient oral anticoagulation for at least 6 months with subsequent acetylsalicylic acid (ASA). More often than previously thought, the recurrence of spontaneous cervical artery dissection (sCAD) involves multiple cervical arteries in sequence. sCAD recurrence frequently appears to cluster within the first 2 months after the index event, rather than occurring steadily over time. The prognosis of recurring sCAD appears benign, particularly in patients already receiving antithrombotic therapy.
NASA Astrophysics Data System (ADS)
Meijs, M.; Debats, O.; Huisman, H.
2015-03-01
In prostate cancer, the detection of metastatic lymph nodes indicates progression from localized disease to metastasized cancer. The detection of positive lymph nodes is, however, a complex and time consuming task for experienced radiologists. Assistance of a two-stage Computer-Aided Detection (CAD) system in MR Lymphography (MRL) is not yet feasible due to the large number of false positives in the first stage of the system. By introducing a multi-structure, multi-atlas segmentation, using an affine transformation followed by a B-spline transformation for registration, the organ location is given by a mean density probability map. The atlas segmentation is semi-automatically drawn with ITK-SNAP, using Active Contour Segmentation. Each anatomic structure is identified by a label number. Registration is performed using Elastix, using Mutual Information and an Adaptive Stochastic Gradient optimization. The dataset consists of the MRL scans of ten patients, with lymph nodes manually annotated in consensus by two expert readers. The feature map of the CAD system consists of the Multi-Atlas and various other features (e.g. Normalized Intensity and multi-scale Blobness). The voxel-based Gentleboost classifier is evaluated using ROC analysis with cross validation. We show in a set of 10 studies that adding multi-structure, multi-atlas anatomical structure likelihood features improves the quality of the lymph node voxel likelihood map. Multiple structure anatomy maps may thus make MRL CAD more feasible.
Is there any relationship between coronary artery disease and postprandial triglyceride levels?
Atar, Inci Aslı; Atar, Ilyas; Aydınalp, Alp; Ertan, Cağatay; Bozbaş, Hüseyin; Ozin, Bülent; Yıldırır, Aylin; Müderrisoğlu, Haldun
2011-05-01
We aimed to evaluate the relationship between postprandial triglyceride (PPTG) levels and coronary artery disease (CAD). A total of 80 patients were included in this prospective cohort study. Oral lipid loading was used in order to measure PPTG levels. In the fasting state and after the high fat breakfast, triglyceride levels were measured by enzymatic methods at 2nd, 4th, 6th and 8th hours. We made subgroup analysis to show the effects of lipid loading on triglyceride levels in patients with and without fasting hypertriglyceridemia. We evaluated triglyceride levels and changes of triglyceride levels in percentages after lipid loading using a general linear model for repeated measures. Sample size analysis was performed. Baseline clinical, demographic and laboratory characteristics of both groups were similar. The peak triglyceride levels were seen at the 4th hour in both groups. Triglyceride levels were significantly increased after lipid-rich-breakfast loading compared to baseline levels in both groups (p<0.001) but these changes were not significant (p=0.279). In patients with elevated fasting triglyceride levels, the area under the plasma triglyceride concentration curve was significantly larger in CAD group than control group (334±103 vs. 233±58 mg/dl, p=0.02). Our data show that in patients who have a high fasting triglyceride level, high levels of PPTG may be related to CAD, however high PPTG levels are not related to CAD in patients with normal fasting levels of triglyceride.
Evaluation of internal fit of interim crown fabricated with CAD/CAM milling and 3D printing system.
Lee, Wan-Sun; Lee, Du-Hyeong; Lee, Kyu-Bok
2017-08-01
This study is to evaluate the internal fit of the crown manufactured by CAD/CAM milling method and 3D printing method. The master model was fabricated with stainless steel by using CNC machine and the work model was created from the vinyl-polysiloxane impression. After scanning the working model, the design software is used to design the crown. The saved STL file is used on the CAD/CAM milling method and two types of 3D printing method to produce 10 interim crowns per group. Internal discrepancy measurement uses the silicon replica method and the measured data are analyzed with One-way ANOVA to verify the statistic significance. The discrepancy means (standard deviation) of the 3 groups are 171.6 (97.4) µm for the crown manufactured by the milling system and 149.1 (65.9) and 91.1 (36.4) µm, respectively, for the crowns manufactured with the two types of 3D printing system. There was a statistically significant difference and the 3D printing system group showed more outstanding value than the milling system group. The marginal and internal fit of the interim restoration has more outstanding 3D printing method than the CAD/CAM milling method. Therefore, the 3D printing method is considered as applicable for not only the interim restoration production, but also in the dental prosthesis production with a higher level of completion.
NASA Astrophysics Data System (ADS)
Deshpande, Ruchi R.; Fernandez, James; Lee, Joon K.; Chan, Tao; Liu, Brent J.; Huang, H. K.
2010-03-01
Timely detection of Acute Intra-cranial Hemorrhage (AIH) in an emergency environment is essential for the triage of patients suffering from Traumatic Brain Injury. Moreover, the small size of lesions and lack of experience on the reader's part could lead to difficulties in the detection of AIH. A CT based CAD algorithm for the detection of AIH has been developed in order to improve upon the current standard of identification and treatment of AIH. A retrospective analysis of the algorithm has already been carried out with 135 AIH CT studies with 135 matched normal head CT studies from the Los Angeles County General Hospital/ University of Southern California Hospital System (LAC/USC). In the next step, AIH studies have been collected from Walter Reed Army Medical Center, and are currently being processed using the AIH CAD system as part of implementing a multi-site assessment and evaluation of the performance of the algorithm. The sensitivity and specificity numbers from the Walter Reed study will be compared with the numbers from the LAC/USC study to determine if there are differences in the presentation and detection due to the difference in the nature of trauma between the two sites. Simultaneously, a stand-alone system with a user friendly GUI has been developed to facilitate implementation in a clinical setting.
A new screening pathway for identifying asymptomatic patients using dental panoramic radiographs
NASA Astrophysics Data System (ADS)
Hayashi, Tatsuro; Matsumoto, Takuya; Sawagashira, Tsuyoshi; Tagami, Motoki; Katsumata, Akitoshi; Hayashi, Yoshinori; Muramatsu, Chisako; Zhou, Xiangrong; Iida, Yukihiro; Matsuoka, Masato; Katagi, Kiyoji; Fujita, Hiroshi
2012-03-01
To identify asymptomatic patients is the challenging task and the essential first step in diagnosis. Findings of dental panoramic radiographs include not only dental conditions but also radiographic signs that are suggestive of possible systemic diseases such as osteoporosis, arteriosclerosis, and maxillary sinusitis. Detection of such signs on panoramic radiographs has a potential to provide supplemental benefits for patients. However, it is not easy for general dental practitioners to pay careful attention to such signs. We addressed the development of a computer-aided detection (CAD) system that detects radiographic signs of pathology on panoramic images, and the design of the framework of new screening pathway by cooperation of dentists and our CAD system. The performance evaluation of our CAD system showed the sensitivity and specificity in the identification of osteoporotic patients were 92.6 % and 100 %, respectively, and those of the maxillary sinus abnormality were 89.6 % and 73.6 %, respectively. The detection rate of carotid artery calcifications that suggests the need for further medical evaluation was approximately 93.6 % with 4.4 false-positives per image. To validate the utility of the new screening pathway, preliminary clinical trials by using our CAD system were conducted. To date, 223 panoramic images were processed and 4 asymptomatic patients with suspected osteoporosis, 7 asymptomatic patients with suspected calcifications, and 40 asymptomatic patients with suspected maxillary sinusitis were detected in our initial trial. It was suggested that our new screening pathway could be useful to identify asymptomatic patients with systemic diseases.
Bakir, May; Nelson, Michael D; Jones, Erika; Li, Quanlin; Wei, Janet; Sharif, Behzad; Minissian, Margo; Shufelt, Chrisandra; Sopko, George; Pepine, Carl J; Merz, C Noel Bairey
2016-11-15
Women with signs and symptoms of ischemia, no obstructive coronary artery disease, and preserved left ventricular ejection fraction enrolled in the National Heart Lung and Blood Institute (NHLBI) sponsored Women's Ischemia Syndrome Evaluation (WISE) study have an unexpectedly high rate of subsequent heart failure (HF) hospitalization. We sought to verify and characterize the HF hospitalizations. A retrospective chart review was performed on 223 women with signs and symptoms of ischemia, undergoing coronary angiography for suspected coronary artery disease followed for 6±2.6years. Data were collected from a single site in the WISE study. At the time of study enrollment, the women were 57±11years of age, all had preserved left ventricular ejection fraction, and 81 (36%) had obstructive CAD (defined as >50% stenosis in at least one epicardial artery). Among the 223 patients, 25 (11%) reported HF hospitalizations, of which 14/25 (56%) had recurrent HF hospitalizations (>2 hospitalizations). Medical records were available in 13/25 (52%) women. Left ventricular ejection fraction was measured in all verified cases and was found to be preserved in 12/13 (92%). HF hospitalization was not related to obstructive CAD. Among women with signs and symptoms of ischemia undergoing coronary angiography for suspected obstructive CAD, HF hospitalization at 6-year follow-up was predominantly characterized by a preserved ejection fraction and not associated with obstructive CAD. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
CAD and CAE Analysis for Siphon Jet Toilet
NASA Astrophysics Data System (ADS)
Wang, Yuhua; Xiu, Guoji; Tan, Haishu
The high precision 3D laser scanner with the dual CCD technology was used to measure the original design sample of a siphon jet toilet. The digital toilet model was constructed from the cloud data measured with the curve and surface fitting technology and the CAD/CAE systems. The Realizable k - ɛ double equation model of the turbulence viscosity coefficient method and the VOF multiphase flow model were used to simulate the flushing flow in the toilet digital model. Through simulating and analyzing the distribution of the flushing flow's total pressure, the flow speed at the toilet-basin surface and the siphoning bent tube, the toilet performance can be evaluated efficiently and conveniently. The method of "establishing digital model, flushing flow simulating, performances evaluating, function shape modifying" would provide a high efficiency approach to develop new water-saving toilets.
Evaluation of prosthetic valve thrombosis by 64-row multi-detector computed tomography. .
Tarzia, Vincenzo; Bortolussi, Giacomo; Rubino, Maurizio; Gallo, Michele; Bottio, Tomaso; Gerosa, Gino
2015-03-01
Multi-detector computed tomography (MDCT), combined with retrospective electrocardiographic gating, permits cardiac imaging with high accuracy. Recent advances in MDCT have seemed to respond adequately to the need for a non-invasive and reliable assessment of the coronary artery lumen. Two patients with prosthetic aortic valves (one bioprosthetic, one mechanical) presented at the authors' institution with dyspnea and syncopal episodes. MDCT was performed to evaluate thrombus characteristics and exclude coronary artery disease (CAD). Based on the MDCT coronary artery assessment, neither patient underwent preoperative invasive coronary angiography, abolishing the risk of any iatrogenic thrombus fragmentation and subsequent embolization. One patient underwent surgical treatment without complications, while medical therapy was successful in the other case. MDCT can be used for the accurate imaging of thrombi on prosthetic aortic valves, and to correctly assess possible CAD.
Design of a miniature implantable left ventricular assist device using CAD/CAM technology.
Okamoto, Eiji; Hashimoto, Takuya; Mitamura, Yoshinori
2003-01-01
In this study, we developed a new miniature motor-driven pulsatile left ventricular assist device (LVAD) for implantation into a Japanese patient of average build by means of computer-aided design and manufacturing (CAD/CAM) technology. A specially designed miniature ball-screw and a high-performance brushless DC motor were used in an artificial heart actuator to allow miniaturization. A blood pump chamber (stroke volume 55 ml) and an inflow and outflow port were designed by computational fluid dynamics (CFD) analysis. The geometry of the blood pump was evaluated using the value of index of pump geometry (IPG) = (Reynolds shear stress) x (occupied volume) as a quantitative index for optimization. The calculated value of IPG varied from 20.6 Nm to 49.1 Nm, depending on small variations in pump geometry. We determined the optimum pump geometry based on the results of quantitative evaluation using IPG and qualitative evaluation using the flow velocity distribution with blood flow tracking. The geometry of the blood pump that gave lower shear stress had more optimum spiral flow around the diaphragm-housing (D-H) junction. The volume and weight of the new LVAD, made of epoxy resin, is 309 ml and 378 g, but further miniaturization will be possible by improving the geometry of both the blood pump and the back casing. Our results show that our new design method for an implantable LVAD using CAD/CAM promises to improve blood compatibility with greater miniaturization.
Effect of the infrastructure material on the failure behavior of prosthetic crowns.
Sonza, Queli Nunes; Della Bona, Alvaro; Borba, Márcia
2014-05-01
To evaluate the effect of infrastructure (IS) material on the fracture behavior of prosthetic crowns. Restorations were fabricated using a metal die simulating a prepared tooth. Four groups were evaluated: YZ-C, Y-TZP (In-Ceram YZ, Vita) IS produced by CAD-CAM; IZ-C, In-Ceram Zirconia (Vita) IS produced by CAD-CAM; IZ-S, In-Ceram Zirconia (Vita) IS produced by slip-cast; MC, metal IS (control). The IS were veneered with porcelain and resin cemented to fiber-reinforced composite dies. Specimens were loaded in compression to failure using a universal testing machine. The 30° angle load was applied by a spherical piston, in 37°C distilled water. Fractography was performed using stereomicroscope and SEM. Data were statistically analyzed with Anova and Student-Newman-Keuls tests (α=0.05). Significant differences were found between groups (p=0.022). MC showed the highest mean failure load, statistically similar to YZ-C. There was no statistical difference between YZ-C, IZ-C and IZ-S. MC and YZ-C showed no catastrophic failure. IZ-C and IZ-S showed chipping and catastrophic failures. The fracture behavior is similar to reported clinical failures. Considering the ceramic systems evaluated, YZ-C and MC crowns present greater fracture load and a more favorable failure mode than In-Ceram Zirconia crowns, regardless of the fabrication type (CAD-CAM or slip-cast). Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Jianming, Yuan; Ying, Tang; Feng, Pan; Weixing, Xu
2016-12-01
This study aims to compare the marginal accuracy of single crowns fabricated using self-curing resin, Luxatemp, and computer aided design/computer aided manufacturing (CAD/CAM) methods in clinical application. A total of 30 working dies, which were obtained from 30 clinical teeth prepared with full crown as standard, were created and made into 30 self-curing resin, Luxatemp, and CAD/CAM single crowns. The restorations were seated on the working dies, and stereomicroscope was used to observe and measure the thickness of reference points. One-way analysis of variance, which was performed using SPSS 19.0 software package, compared the marginal gap widths of self-curing resin, Luxatemp, and CAD/CAM provisional crowns. The mean marginal gap widths of the fabricated self-curing resin, Luxatemp, and CAD/CAM were (179.06±33.24), (88.83±9.56), and (43.61±7.27) μm, respectively. A significant difference was observed among the three provisional crowns (P<0.05). The marginal gap width of CAD/CAM provisional crown was lower than that of the self-curing resin and Luxatemp. Thus, the CAD/CAM provisional crown offers a better remediation effect in clinical application.
Foundation and methodologies in computer-aided diagnosis systems for breast cancer detection.
Jalalian, Afsaneh; Mashohor, Syamsiah; Mahmud, Rozi; Karasfi, Babak; Saripan, M Iqbal B; Ramli, Abdul Rahman B
2017-01-01
Breast cancer is the most prevalent cancer that affects women all over the world. Early detection and treatment of breast cancer could decline the mortality rate. Some issues such as technical reasons, which related to imaging quality and human error, increase misdiagnosis of breast cancer by radiologists. Computer-aided detection systems (CADs) are developed to overcome these restrictions and have been studied in many imaging modalities for breast cancer detection in recent years. The CAD systems improve radiologists' performance in finding and discriminating between the normal and abnormal tissues. These procedures are performed only as a double reader but the absolute decisions are still made by the radiologist. In this study, the recent CAD systems for breast cancer detection on different modalities such as mammography, ultrasound, MRI, and biopsy histopathological images are introduced. The foundation of CAD systems generally consist of four stages: Pre-processing, Segmentation, Feature extraction, and Classification. The approaches which applied to design different stages of CAD system are summarised. Advantages and disadvantages of different segmentation, feature extraction and classification techniques are listed. In addition, the impact of imbalanced datasets in classification outcomes and appropriate methods to solve these issues are discussed. As well as, performance evaluation metrics for various stages of breast cancer detection CAD systems are reviewed.
Detecting Anomalous Insiders in Collaborative Information Systems
Chen, You; Nyemba, Steve; Malin, Bradley
2012-01-01
Collaborative information systems (CISs) are deployed within a diverse array of environments that manage sensitive information. Current security mechanisms detect insider threats, but they are ill-suited to monitor systems in which users function in dynamic teams. In this paper, we introduce the community anomaly detection system (CADS), an unsupervised learning framework to detect insider threats based on the access logs of collaborative environments. The framework is based on the observation that typical CIS users tend to form community structures based on the subjects accessed (e.g., patients’ records viewed by healthcare providers). CADS consists of two components: 1) relational pattern extraction, which derives community structures and 2) anomaly prediction, which leverages a statistical model to determine when users have sufficiently deviated from communities. We further extend CADS into MetaCADS to account for the semantics of subjects (e.g., patients’ diagnoses). To empirically evaluate the framework, we perform an assessment with three months of access logs from a real electronic health record (EHR) system in a large medical center. The results illustrate our models exhibit significant performance gains over state-of-the-art competitors. When the number of illicit users is low, MetaCADS is the best model, but as the number grows, commonly accessed semantics lead to hiding in a crowd, such that CADS is more prudent. PMID:24489520
Leucker, Thorsten M.; Valenta, Ines; Schindler, Thomas Hellmut
2017-01-01
Positron emission tomography/computed tomography (PET/CT) applied with positron-emitting flow tracers such as 13N-ammonia and 82Rubidium enables the quantification of both myocardial perfusion and myocardial blood flow (MBF) in milliliters per gram per minute for coronary artery disease (CAD) detection and characterization. The detection of a regional myocardial perfusion defect during vasomotor stress commonly identifies the culprit lesion or most severe epicardial narrowing, whereas adding regional hyperemic MBFs, myocardial flow reserve (MFR), and/or longitudinal flow decrease may also signify less severe but flow-limiting stenosis in multivessel CAD. The addition of regional hyperemic flow parameters, therefore, may afford a comprehensive identification and characterization of flow-limiting effects of multivessel CAD. The non-specific origin of decreases in hyperemic MBFs and MFR, however, prompts an evaluation and interpretation of regional flow in the appropriate context with the presence of obstructive CAD. Conversely, initial results of the assessment of a longitudinal hyperemic flow gradient suggest this novel flow parameter to be specifically related to increases in CAD caused epicardial resistance. The concurrent assessment of myocardial perfusion and several hyperemic flow parameters with PET/CT may indeed open novel avenues of precision medicine to guide coronary revascularization procedures that may potentially lead to a further improvement in cardiovascular outcomes in CAD patients. PMID:28770213
Foundation and methodologies in computer-aided diagnosis systems for breast cancer detection
Jalalian, Afsaneh; Mashohor, Syamsiah; Mahmud, Rozi; Karasfi, Babak; Saripan, M. Iqbal B.; Ramli, Abdul Rahman B.
2017-01-01
Breast cancer is the most prevalent cancer that affects women all over the world. Early detection and treatment of breast cancer could decline the mortality rate. Some issues such as technical reasons, which related to imaging quality and human error, increase misdiagnosis of breast cancer by radiologists. Computer-aided detection systems (CADs) are developed to overcome these restrictions and have been studied in many imaging modalities for breast cancer detection in recent years. The CAD systems improve radiologists' performance in finding and discriminating between the normal and abnormal tissues. These procedures are performed only as a double reader but the absolute decisions are still made by the radiologist. In this study, the recent CAD systems for breast cancer detection on different modalities such as mammography, ultrasound, MRI, and biopsy histopathological images are introduced. The foundation of CAD systems generally consist of four stages: Pre-processing, Segmentation, Feature extraction, and Classification. The approaches which applied to design different stages of CAD system are summarised. Advantages and disadvantages of different segmentation, feature extraction and classification techniques are listed. In addition, the impact of imbalanced datasets in classification outcomes and appropriate methods to solve these issues are discussed. As well as, performance evaluation metrics for various stages of breast cancer detection CAD systems are reviewed. PMID:28435432
Zhou, Dong; Wang, Xinhong; Chen, Tao; Wen, Wen; Liu, Yang; Wu, Yue; Yuan, Zuyi
2016-01-01
The objective of this study is to investigate the potential association of the NLRP3 rs10754558 and CARD8 rs2043211 polymorphisms with the occurrence and prognosis of CAD. Gene polymorphisms were analyzed using the ABI PRISM-Snapshot multiplex method in 515 CAD patients and 401 control subjects. The serum level of IL-1β was investigated by ELISA assays. The clinical endpoints were evaluated during a median follow-up period of 32 months. The NLRP3 rs10754558 gene polymorphism was significantly associated with the occurrence of CAD, while the CARD8 rs2043211 gene polymorphism was not involved. Patients carrying G allele of NLRP3 rs10754558 had more severe coronary artery stenosis. Multivariable analysis revealed a significant association of the G allele with major adverse cardiac event. The serum IL-1β concentrations in patients with GG genotype were significantly increased compared with those in the patients with CC genotype. Our findings for the first time show that the NLRP3 rs10754558 polymorphism is involved in the occurrence of CAD in the Chinese Han population; and G allele can effectively predict clinical outcome of CAD. The G allele susceptibility to CAD is maybe associated with the increased level of serum IL-1β.
Balleyguier, Corinne; Arfi-Rouche, Julia; Levy, Laurent; Toubiana, Patrick R; Cohen-Scali, Franck; Toledano, Alicia Y; Boyer, Bruno
2017-12-01
Evaluate concurrent Computer-Aided Detection (CAD) with Digital Breast Tomosynthesis (DBT) to determine impact on radiologist performance and reading time. The CAD system detects and extracts suspicious masses, architectural distortions and asymmetries from DBT planes that are blended into corresponding synthetic images to form CAD-enhanced synthetic images. Review of CAD-enhanced images and navigation to corresponding planes to confirm or dismiss potential lesions allows radiologists to more quickly review DBT planes. A retrospective, crossover study with and without CAD was conducted with six radiologists who read an enriched sample of 80 DBT cases including 23 malignant lesions in 21 women. Area Under the Receiver Operating Characteristic (ROC) Curve (AUC) compared the readings with and without CAD to determine the effect of CAD on overall interpretation performance. Sensitivity, specificity, recall rate and reading time were also assessed. Multi-reader, multi-case (MRMC) methods accounting for correlation and requiring correct lesion localization were used to analyze all endpoints. AUCs were based on a 0-100% probability of malignancy (POM) score. Sensitivity and specificity were based on BI-RADS scores, where 3 or higher was positive. Average AUC across readers without CAD was 0.854 (range: 0.785-0.891, 95% confidence interval (CI): 0.769,0.939) and 0.850 (range: 0.746-0.905, 95% CI: 0.751,0.949) with CAD (95% CI for difference: -0.046,0.039), demonstrating non-inferiority of AUC. Average reduction in reading time with CAD was 23.5% (95% CI: 7.0-37.0% improvement), from an average 48.2 (95% CI: 39.1,59.6) seconds without CAD to 39.1 (95% CI: 26.2,54.5) seconds with CAD. Per-patient sensitivity was the same with and without CAD (0.865; 95% CI for difference: -0.070,0.070), and there was a small 0.022 improvement (95% CI for difference: -0.046,0.089) in per-lesion sensitivity from 0.790 without CAD to 0.812 with CAD. A slight reduction in specificity with a -0.014 difference (95% CI for difference: -0.079,0.050) and a small 0.025 increase (95% CI for difference: -0.036,0.087) in recall rate in non-cancer cases were observed with CAD. Concurrent CAD resulted in faster reading time with non-inferiority of radiologist interpretation performance. Radiologist sensitivity, specificity and recall rate were similar with and without CAD. Copyright © 2017 Elsevier B.V. All rights reserved.
Diagnostic performance of an acoustic-based system for coronary artery disease risk stratification.
Winther, Simon; Nissen, Louise; Schmidt, Samuel Emil; Westra, Jelmer Sybren; Rasmussen, Laust Dupont; Knudsen, Lars Lyhne; Madsen, Lene Helleskov; Kirk Johansen, Jane; Larsen, Bjarke Skogstad; Struijk, Johannes Jan; Frost, Lars; Holm, Niels Ramsing; Christiansen, Evald Høj; Botker, Hans Erik; Bøttcher, Morten
2018-06-01
Diagnosing coronary artery disease (CAD) continues to require substantial healthcare resources. Acoustic analysis of transcutaneous heart sounds of cardiac movement and intracoronary turbulence due to obstructive coronary disease could potentially change this. The aim of this study was thus to test the diagnostic accuracy of a new portable acoustic device for detection of CAD. We included 1675 patients consecutively with low to intermediate likelihood of CAD who had been referred for cardiac CT angiography. If significant obstruction was suspected in any coronary segment, patients were referred to invasive angiography and fractional flow reserve (FFR) assessment. Heart sound analysis was performed in all patients. A predefined acoustic CAD-score algorithm was evaluated; subsequently, we developed and validated an updated CAD-score algorithm that included both acoustic features and clinical risk factors. Low risk is indicated by a CAD-score value ≤20. Haemodynamically significant CAD assessed from FFR was present in 145 (10.0%) patients. In the entire cohort, the predefined CAD-score had a sensitivity of 63% and a specificity of 44%. In total, 50% had an updated CAD-score value ≤20. At this cut-off, sensitivity was 81% (95% CI 73% to 87%), specificity 53% (95% CI 50% to 56%), positive predictive value 16% (95% CI 13% to 18%) and negative predictive value 96% (95% CI 95% to 98%) for diagnosing haemodynamically significant CAD. Sound-based detection of CAD enables risk stratification superior to clinical risk scores. With a negative predictive value of 96%, this new acoustic rule-out system could potentially supplement clinical assessment to guide decisions on the need for further diagnostic investigation. ClinicalTrials.gov identifier NCT02264717; Results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Rotger, Margalida; Glass, Tracy R.; Junier, Thomas; Lundgren, Jens; Neaton, James D.; Poloni, Estella S.; van 't Wout, Angélique B.; Lubomirov, Rubin; Colombo, Sara; Martinez, Raquel; Rauch, Andri; Günthard, Huldrych F.; Neuhaus, Jacqueline; Wentworth, Deborah; van Manen, Danielle; Gras, Luuk A.; Schuitemaker, Hanneke; Albini, Laura; Torti, Carlo; Jacobson, Lisa P.; Li, Xiuhong; Kingsley, Lawrence A.; Carli, Federica; Guaraldi, Giovanni; Ford, Emily S.; Sereti, Irini; Hadigan, Colleen; Martinez, Esteban; Arnedo, Mireia; Egaña-Gorroño, Lander; Gatell, Jose M.; Law, Matthew; Bendall, Courtney; Petoumenos, Kathy; Rockstroh, Jürgen; Wasmuth, Jan-Christian; Kabamba, Kabeya; Delforge, Marc; De Wit, Stephane; Berger, Florian; Mauss, Stefan; de Paz Sierra, Mariana; Losso, Marcelo; Belloso, Waldo H.; Leyes, Maria; Campins, Antoni; Mondi, Annalisa; De Luca, Andrea; Bernardino, Ignacio; Barriuso-Iglesias, Mónica; Torrecilla-Rodriguez, Ana; Gonzalez-Garcia, Juan; Arribas, José R.; Fanti, Iuri; Gel, Silvia; Puig, Jordi; Negredo, Eugenia; Gutierrez, Mar; Domingo, Pere; Fischer, Julia; Fätkenheuer, Gerd; Alonso-Villaverde, Carlos; Macken, Alan; Woo, James; McGinty, Tara; Mallon, Patrick; Mangili, Alexandra; Skinner, Sally; Wanke, Christine A.; Reiss, Peter; Weber, Rainer; Bucher, Heiner C.; Fellay, Jacques; Telenti, Amalio; Tarr, Philip E.
2013-01-01
Background Persons infected with human immunodeficiency virus (HIV) have increased rates of coronary artery disease (CAD). The relative contribution of genetic background, HIV-related factors, antiretroviral medications, and traditional risk factors to CAD has not been fully evaluated in the setting of HIV infection. Methods In the general population, 23 common single-nucleotide polymorphisms (SNPs) were shown to be associated with CAD through genome-wide association analysis. Using the Metabochip, we genotyped 1875 HIV-positive, white individuals enrolled in 24 HIV observational studies, including 571 participants with a first CAD event during the 9-year study period and 1304 controls matched on sex and cohort. Results A genetic risk score built from 23 CAD-associated SNPs contributed significantly to CAD (P = 2.9×10−4). In the final multivariable model, participants with an unfavorable genetic background (top genetic score quartile) had a CAD odds ratio (OR) of 1.47 (95% confidence interval [CI], 1.05–2.04). This effect was similar to hypertension (OR = 1.36; 95% CI, 1.06–1.73), hypercholesterolemia (OR = 1.51; 95% CI, 1.16–1.96), diabetes (OR = 1.66; 95% CI, 1.10–2.49), ≥1 year lopinavir exposure (OR = 1.36; 95% CI, 1.06–1.73), and current abacavir treatment (OR = 1.56; 95% CI, 1.17–2.07). The effect of the genetic risk score was additive to the effect of nongenetic CAD risk factors, and did not change after adjustment for family history of CAD. Conclusions In the setting of HIV infection, the effect of an unfavorable genetic background was similar to traditional CAD risk factors and certain adverse antiretroviral exposures. Genetic testing may provide prognostic information complementary to family history of CAD. PMID:23532479
Impact of cardiac hybrid imaging-guided patient management on clinical long-term outcome.
Benz, Dominik C; Gaemperli, Lara; Gräni, Christoph; von Felten, Elia; Giannopoulos, Andreas A; Messerli, Michael; Buechel, Ronny R; Gaemperli, Oliver; Pazhenkottil, Aju P; Kaufmann, Philipp A
2018-06-15
Although randomized trials have provided evidence for invasive fractional flow reserve to guide revascularization, evidence for non-invasive imaging is less well established. The present study investigated whether hybrid coronary computed tomography (CCTA)/single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) can identify patients who benefit from early revascularization compared to medical therapy. This retrospective study consists of 414 patients referred for evaluation of known or suspected coronary artery disease (CAD) with CCTA/SPECT hybrid imaging. CCTA categorized patients into no CAD, non-high-risk CAD and high-risk CAD. In patients with CAD (n = 329), a matched finding (n = 75) was defined as a reversible perfusion defect in a territory subtended by a coronary artery with CAD. All other combinations of pathologic findings were classified as unmatched (n = 254). Death, myocardial infarction, unstable angina requiring hospitalization, and late coronary revascularization were defined as major adverse cardiac events (MACE). Cox hazards models included covariates age, male gender, more than two risk factors, previous CABG, high-risk CAD and early revascularization. During median follow-up of 6.0 years, 112 patients experienced a MACE (27%). Early revascularization (n = 50) was independently associated with improved outcome among patients with a matched finding (p < 0.001). There was no benefit among patients with an unmatched finding (p = 0.787), irrespective of presence (p = 0.505) or absence of high-risk CAD (p = 0.631). Early revascularization is associated with an outcome benefit in CAD patients with a matched finding documented by cardiac hybrid imaging while no benefit of revascularization was observed in patients with an unmatched finding. Copyright © 2018 Elsevier B.V. All rights reserved.
Javadzadeh, Alireza; Ghorbanihaghjo, Amir; Adl, Farzad Hami; Andalib, Dima; Khojasteh-Jafari, Hassan
2013-01-01
Purpose To determine the benefits of calcium dobesilate (CaD) administration on endothelial function and inflammatory status in patients with diabetic retinopathy through measurement of serum levels of endothelin-1 and high-sensitivity C-reactive protein (hsCRP). Methods In a double-blind, randomized clinical trial, 90 patients with either severe nonproliferative or proliferative diabetic retinopathy and with blood glucose level of 120–200 mg/dl were randomly allocated to treatment with either CaD tablets (500 mg daily) or placebo for 3 months. Visual acuity, intraocular pressure, and macular status were performed before the study. The serum levels of endothelin-1 and hsCRP were evaluated in both groups before and at the third month of the trial. Results The median serum level of hsCRP significantly differed between the groups 3 months following the CaD or placebo administration (2.2 mg/l in the CaD group versus 3.7 mg/l in the placebo group, p=0.01). The mean endothelin-1 serum level was 0.69±0.32 pg/ml in the CaD group and 0.86±0.30 pg/ml in the placebo group (p=0.01). Furthermore, in the CaD group, the serum levels of both endothelin-1 and hsCRP were significantly decreased 3 months after administration of CaD (p<0.001). Conclusions Administration of the CaD in the patients with diabetic retinopathy may reduce the serum levels of endothelin-1 and hsCRP. This might imply amelioration of the endothelial function and inflammatory status following CaD therapy in these patients. PMID:23335852
Elsaka, Shaymaa E
2014-12-01
To evaluate the effect of different surface treatments on the microtensile bond strength (μTBS) of novel CAD/CAM restorative materials to self-adhesive resin cement. Two types of CAD/CAM restorative materials (Vita Enamic [VE] and Lava Ultimate [LU]) were used. The specimens were divided into five groups in each test according to the surface treatment performed; Gr 1 (control; no treatment), Gr 2 (sandblasted [SB]), Gr 3 (SB+silane [S]), Gr 4 (hydrofluoric acid [HF]), and Gr 5 (HF+S). A dual-curing self-adhesive resin cement (Bifix SE [BF]) was applied to each group for testing the adhesion after 24 h of storage in distilled water or after 30 days using the μTBS test. Following fracture testing, specimens were examined with a stereomicroscope and SEM. Surface roughness and morphology of the CAD/CAM restorative materials were characterized after treatment. Data were analyzed using ANOVA and Tukey's test. The surface treatment, type of CAD/CAM restorative material, and water storage periods showed a significant effect on the μTBS (p<0.001). For the LU/BF system, there was no significant difference in the bond strength values between different surface treatments (p>0.05). On the other hand, for the VE/BF system, surface treatment with HF+S showed higher bond strength values compared with SB and HF surface treatments (p<0.05). Surface roughness and SEM analyses showed that the surface topography of CAD/CAM restorative materials was modified after treatments. The effect of surface treatments on the bond strength of novel CAD/CAM restorative materials to resin cement is material dependent. The VE/BF CAD/CAM material provided higher bond strength values compared with the LU/BF CAD/CAM material.
Psychiatric Characteristics of the Cardiac Outpatients with Chest Pain
Lee, Jea-Geun; Kim, Song-Yi; Kim, Ki-Seok; Joo, Seung-Jae
2016-01-01
Background and Objectives A cardiologist's evaluation of psychiatric symptoms in patients with chest pain is rare. This study aimed to determine the psychiatric characteristics of patients with and without coronary artery disease (CAD) and explore their relationship with the intensity of chest pain. Subjects and Methods Out of 139 consecutive patients referred to the cardiology outpatient department, 31 with atypical chest pain (heartburn, acid regurgitation, dyspnea, and palpitation) were excluded and 108 were enrolled for the present study. The enrolled patients underwent complete numerical rating scale of chest pain and the symptom checklist for minor psychiatric disorders at the time of first outpatient visit. The non-CAD group consisted of patients with a normal stress test, coronary computed tomography angiogram, or coronary angiogram, and the CAD group included those with an abnormal coronary angiogram. Results Nineteen patients (17.6%) were diagnosed with CAD. No differences in the psychiatric characteristics were observed between the groups. "Feeling tense", "self-reproach", and "trouble falling asleep" were more frequently observed in the non-CAD (p=0.007; p=0.046; p=0.044) group. In a multiple linear regression analysis with a stepwise selection, somatization without chest pain in the non-CAD group and hypochondriasis in the CAD group were linearly associated with the intensity of chest pain (β=0.108, R2=0.092, p=0.004; β= -0.525, R2=0.290, p=0.010). Conclusion No differences in psychiatric characteristics were observed between the groups. The intensity of chest pain was linearly associated with somatization without chest pain in the non-CAD group and inversely linearly associated with hypochondriasis in the CAD group. PMID:27014347
Sánchez-Osuna, María; Martínez-Escardó, Laura; Granados-Colomina, Carla; Martínez-Soler, Fina; Pascual-Guiral, Sònia; Iglesias-Guimarais, Victoria; Velasco, Roser; Plans, Gerard; Vidal, Noemi; Tortosa, Avelina; Barcia, Carlos; Bruna, Jordi; Yuste, Victor J
2016-07-01
Glioblastoma (GBM) or grade IV astrocytoma is one of the most devastating human cancers. The loss of DFF40/CAD, the key endonuclease that triggers oligonucleosomal DNA fragmentation during apoptosis, has been linked to genomic instability and cell survival after radiation. Despite the near inevitability of GBM tumor recurrence after treatment, the relationship between DFF40/CAD and GBM remains unexplored. We studied the apoptotic behavior of human GBM-derived cells after apoptotic insult. We analyzed caspase activation and the protein levels and subcellular localization of DFF40/CAD apoptotic endonuclease. DFF40/CAD was also evaluated in histological sections from astrocytic tumors and nontumoral human brain. We showed that GBM cells undergo incomplete apoptosis without generating oligonucleosomal DNA degradation despite the correct activation of executioner caspases. The major defect of GBM cells relied on the improper accumulation of DFF40/CAD at the nucleoplasmic subcellular compartment. Supporting this finding, DFF40/CAD overexpression allowed GBM cells to display oligonucleosomal DNA degradation after apoptotic challenge. Moreover, the analysis of histological slices from astrocytic tumors showed that DFF40/CAD immunoreactivity in tumoral GFAP-positive cells was markedly reduced when compared with nontumoral samples. Our data highlight the low expression levels of DFF40/CAD and the absence of DNA laddering as common molecular traits in GBM. These findings could be of major importance for understanding the malignant behavior of remaining tumor cells after radiochemotherapy. © The Author(s) 2016. Published by Oxford University Press on behalf of the Society for Neuro-Oncology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Allameh, Farzad; Pourmand, Gholamreza; Bozorgi, Ali; Nekuie, Sepideh; Namdari, Farshad
2016-01-01
The aim of the study was to evaluate the relationship between the serum levels of androgens and Coronary Artery Disease (CAD) in an Iranian population. Male individuals admitted to Tehran Heart Center and Sina Hospital, Tehran, Iran from 2011-2012 were categorized into CAD and control groups based on selective coronary angiography. Baseline demographic data, including age, BMI, diabetes, and a history of hypertension were recorded. Patients were also assessed for their serum levels of total testosterone, free testosterone, estradiol, dehydroepi and rosterone sulfate (DHEA-S), and Sex Hormone Binding Globulin (SHBG). Data analysis was carried out chi-square and ANOVA tests as well as logistic regression analysis. Two hundred patients were in the CAD group and 135 individuals in control group. In the CAD group, 69 had single-vessel disease, 49 had two-vessel diseases, and 82 had three-vessel diseases. Statistically significant differences were observed between the individuals in the two groups with respect to age (P<0.0001), diabetes (P<0.0001), and a history of hypertension (P=0.018). The serum levels of free testosterone (P=0.048) and DHEA-S (P<0.0001) were significantly higher in the control group than in the CAD group; however, the serum level of SHBG was higher in the CAD group than in the control group (P=0.007). Results of the logistic regression analysis indicated that only age (P=0.042) and diabetes (P=0.003) had significant relationships with CAD. Although the serum levels of some of the androgens were significantly different between the two groups, no association was found between androgenic hormone levels and the risk of CAD, due mainly to the effect of age and diabetes.
Structured reporting platform improves CAD-RADS assessment.
Szilveszter, Bálint; Kolossváry, Márton; Karády, Júlia; Jermendy, Ádám L; Károlyi, Mihály; Panajotu, Alexisz; Bagyura, Zsolt; Vecsey-Nagy, Milán; Cury, Ricardo C; Leipsic, Jonathon A; Merkely, Béla; Maurovich-Horvat, Pál
2017-11-01
Structured reporting in cardiac imaging is strongly encouraged to improve quality through consistency. The Coronary Artery Disease - Reporting and Data System (CAD-RADS) was recently introduced to facilitate interdisciplinary communication of coronary CT angiography (CTA) results. We aimed to assess the agreement between manual and automated CAD-RADS classification using a structured reporting platform. Five readers prospectively interpreted 500 coronary CT angiographies using a structured reporting platform that automatically calculates the CAD-RADS score based on stenosis and plaque parameters manually entered by the reader. In addition, all readers manually assessed CAD-RADS blinded to the automatically derived results, which was used as the reference standard. We evaluated factors influencing reader performance including CAD-RADS training, clinical load, time of the day and level of expertise. Total agreement between manual and automated classification was 80.2%. Agreement in stenosis categories was 86.7%, whereas the agreement in modifiers was 95.8% for "N", 96.8% for "S", 95.6% for "V" and 99.4% for "G". Agreement for V improved after CAD-RADS training (p = 0.047). Time of the day and clinical load did not influence reader performance (p > 0.05 both). Less experienced readers had a higher total agreement as compared to more experienced readers (87.0% vs 78.0%, respectively; p = 0.011). Even though automated CAD-RADS classification uses data filled in by the readers, it outperforms manual classification by preventing human errors. Structured reporting platforms with automated calculation of the CAD-RADS score might improve data quality and support standardization of clinical decision making. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Toothbrushing alters the surface roughness and gloss of composite resin CAD/CAM blocks.
Kamonkhantikul, Krid; Arksornnukit, Mansuang; Lauvahutanon, Sasipin; Takahashi, Hidekazu
2016-01-01
This study investigated the surface roughness and gloss of composite resin CAD/CAM blocks after toothbrushing. Five composite resin blocks (Block HC, Cerasmart, Gradia Block, KZR-CAD Hybrid Resin Block, and Lava Ultimate), one hybrid ceramic (Vita Enamic), one feldspar ceramic (Vitablocs Mark II), one PMMA block (Telio CAD), and one conventional composite resin (Filtek Z350 XT) were evaluated. Surface roughness (Ra) and gloss were determined for each group of materials (n=6) after silicon carbide paper (P4000) grinding, 10k, 20k, and 40k toothbrushing cycles. One-way repeated measures ANOVA indicated significant differences in the Ra and gloss of each material except for the Ra of GRA. After 40k toothbrushing cycles, the Ra of BLO and TEL showed significant increases, while CER, KZR, ULT, and Z350 showed significant decreases. GRA, ENA, and VIT maintained their Ra. All of the materials tested, except CER, demonstrated significant decreases in gloss after 40k toothbrushing cycles.
Shear bond, wettability and AFM evaluations on CO2 laser-irradiated CAD/CAM ceramic surfaces.
El Gamal, Ahmed; Medioni, Etienne; Rocca, Jean Paul; Fornaini, Carlo; Muhammad, Omid H; Brulat-Bouchard, Nathalie
2017-05-01
The purpose of this study is to determine the CO 2 laser irradiation in comparison with sandblasting (Sb), hydrofluoric acid (Hf) and silane coupling agent (Si) on shear bond strength (SBS), roughness (Rg) and wettability (Wt) of resin cement to CAD/CAM ceramics. Sixty (CAD/CAM) ceramic discs were prepared and distributed into six different groups: group A, control lithium disilicate (Li); group B, control zirconia (Zr); group C, Li: CO 2 /HF/Si; group D, Li: HF/Si; group E, Zr: CO 2 /Sb/Si; group F, Zr: Sb/Si. Result showed significant difference between irradiated and non-irradiated in terms of shear bond strength for zirconia ceramics (p value = 0.014). Moreover, partial surface wettability for irradiated and non-irradiated ceramics. Irradiated surface demonstrated more rough surface in lithium disilicate than zirconia ceramics. CO 2 irradiation could increase shear bond strength, surface roughness and wettability for both CAD/CAM ceramics.
Comparative effects of L-DOPA and velvet bean seed extract on soybean lignification.
Bido, Graciene de Souza; Silva, Hingrid Ariane da; Bortolo, Tiara da Silva Coelho; Maldonado, Marcos Rodrigues; Marchiosi, Rogério; Dos Santos, Wanderley Dantas; Ferrarese-Filho, Osvaldo
2018-04-03
Velvet bean (Mucuna pruriens) is an efficient cover forage that controls weeds, pathogens and nematodes, and the non-protein amino acid L-3,4-dihydroxyphenylalanine (L-DOPA) is its main allelochemical. The effects of 3 g L -1 of an aqueous extract of velvet bean seeds, along with 0.5 mM L-DOPA for comparison, were evaluated in roots, stems and leaves of soybean (Glycine max). The activities of phenylalanine ammonia lyase (PAL) and cinnamyl alcohol dehydrogenase (CAD) were determined, along with the lignin content and its monomeric composition. The results revealed similar effects caused by L-DOPA and the aqueous extract. Both treatments reduced PAL and CAD activities, lignin, and lignin monomer contents in roots; PAL and CAD activities in stems, and CAD activity in leaves. These findings provide further evidence that the effects of velvet bean cover forage on root lignification were due to the L-DOPA, its major allelochemical.
Edelhoff, Daniel; Beuer, Florian; Schweiger, Josef; Brix, Oliver; Stimmelmayr, Michael; Guth, Jan-Frederik
2012-06-01
Complex rehabilitations represent a particular challenge for the restorative team, especially if the vertical dimension of occlusion (VDO) needs to be reconstructed or redefined. The use of provisional acrylic or composite materials allows clinicians to evaluate the treatment objective over a certain period of time and therefore generates a high predictability of the definitive rehabilitation in terms of esthetics and function. CAD/CAM technology enables the use of prefabricated polymer materials, which are fabricated under industrial conditions to form a highly homogeneous structure compared with those of direct fabrication. This increases long-term stability, biocompatibility, and resistance to wear. Furthermore, they offer more suitable CAD/CAM processing characteristics and can be used in thinner thicknesses than ceramic restorative materials. Also, based on the improved long-term stability, the transfer into the definitive restoration can be divided into multiple treatment steps. This article presents different clinical cases with minimally invasive indications for CAD/CAM-fabricated temporary restorations for the pretreatment of complex cases.
Housholder-Hughes, Susan D; Martin, Melanie M; McFarland, Marilyn R; Creech, Constance J; Shea, Michael J
Atherosclerotic cardiovascular disease is the foremost cause of death for U.S. adults. The 2013 ACC/AHA Adult Cholesterol Guidelines recommend high-intensity dose statins for individuals with coronary artery disease (CAD). To determine healthcare provider compliance with the Cholesterol Guideline recommendation specific to high-intensity dose statins for patients with CAD. A retrospective chart review was conducted to determine compliance rate. A questionnaire was developed to evaluate healthcare provider beliefs, attitudes, and self-confidence toward this recommendation. Of the 473 patients with CAD, 67% were prescribed a high-intensity dose statin. Patients with non-ST segment myocardial infarction and ST segment myocardial infarction were more likely to be prescribed a high-intensity dose statin versus a moderate or low-intensity dose. Healthcare providers strongly agreed with this guideline recommendation. There exists a dichotomy between intention to prescribe and actual prescribing behaviors of high-intensity dose statin for patients with CAD. Copyright © 2017 Elsevier Inc. All rights reserved.
The clinical evaluation of the CADence device in the acoustic detection of coronary artery disease.
Thomas, Joseph L; Ridner, Michael; Cole, Jason H; Chambers, Jeffrey W; Bokhari, Sabahat; Yannopoulos, Demetris; Kern, Morton; Wilson, Robert F; Budoff, Matthew J
2018-06-23
The noninvasive detection of turbulent coronary flow may enable diagnosis of significant coronary artery disease (CAD) using novel sensor and analytic technology. Eligible patients (n = 1013) with chest pain and CAD risk factors undergoing nuclear stress testing were studied using the CADence (AUM Cardiovascular Inc., Northfield MN) acoustic detection (AD) system. The trial was designed to demonstrate non-inferiority of AD for diagnostic accuracy in detecting significant CAD as compared to an objective performance criteria (sensitivity 83% and specificity 80%, with 15% non-inferiority margins) for nuclear stress testing. AD analysis was blinded to clinical, core lab-adjudicated angiographic, and nuclear data. The presence of significant CAD was determined by computed tomographic (CCTA) or invasive angiography. A total of 1013 subjects without prior coronary revascularization or Q-wave myocardial infarction were enrolled. Primary analysis was performed on subjects with complete angiographic and AD data (n = 763) including 111 subjects (15%) with severe CAD based on CCTA (n = 34) and invasive angiography (n = 77). The sensitivity and specificity of AD were 78% (p = 0.012 for non-inferiority) and 35% (p < 0.001 for failure to demonstrate non-inferiority), respectively. AD results had a high 91% negative predictive value for the presence of significant CAD. AD testing failed to demonstrate non-inferior diagnostic accuracy as compared to the historical performance of a nuclear stress OPC due to low specificity. AD sensitivity was non-inferior in detecting significant CAD with a high negative predictive value supporting a potential value in excluding CAD.
Kömürcüoğlu, Meltem Bektaş; Sağırkaya, Elçin
2017-01-01
PURPOSE To evaluate the effects of different surface treatments on the bond strength of novel CAD/CAM restorative materials to resin cement by four point bending test. MATERIALS AND METHODS The CAD/CAM materials under investigation were e.max CAD, Mark II, Lava Ultimate, and Enamic. A total of 400 bar specimens (4×1.2×12 mm) (n=10) milled from the CAD/CAM blocks underwent various pretreatments (no pretreatment (C), hydrofluoric acid (A), hydrofluoric acid + universal adhesive (Scotchbond) (AS), sandblasting (Sb), and sandblasting + universal adhesive (SbS)). The bars were luted end-to-end on the prepared surfaces with a dual curing adhesive resin cement (Variolink N, Ivoclar Vivadent) on the custom-made stainless steel mold. Ten test specimens for each treatment and material combination were performed with four point bending test method. Data were analyzed using ANOVA and Tukey's test. RESULTS The surface treatment and type of CAD/CAM restorative material showed a significant effect on the four point bending strength (FPBS) (P<.001). For LDC, AS surface treatment showed the highest FPBS results (100.31 ± 10.7 MPa) and the lowest values were obtained in RNC (23.63 ± 9.0 MPa) for control group. SEM analyses showed that the surface topography of CAD/CAM restorative materials was modified after treatments. CONCLUSION The surface treatment of sandblasting or HF acid etching in combination with a universal adhesive containing MDP can be suggested for the adhesive cementation of the novel CAD/CAM restorative materials. PMID:29279763
Aortic stiffness improves the prediction of both diagnosis and severity of coronary artery disease.
Yannoutsos, Alexandra; Ahouah, Mathieu; Dreyfuss Tubiana, Céline; Topouchian, Jirar; Safar, Michel E; Blacher, Jacques
2018-02-01
Elective coronography has low diagnostic yield for obstructive coronary artery disease (CAD). We aim to determine whether non-invasive aortic stiffness assessment improves diagnostic accuracy of CAD screening by reducing the number of false-positive results from the cardiac stress test. A cross-sectional study was conducted from January 2013 to September 2014 in our medical center. Electrocardiogram (ECG) stress test coupled with nuclear imaging was performed in 367 consecutive patients routinely followed for myocardial ischemia screening. Aortic pulse wave velocity (PWV) was assessed by applanation tonometry in the overall population. Forty-two patients underwent elective coronography because of ischemia. Theoretical PWV was calculated according to age, blood pressure and gender. The results were expressed as an index ((measured PWV-theoretical PWV)/theoretical PWV) for each patient. Ten patients presented with obstructive CAD, 16 patients had non-obstructive CAD and 16 patients had normal coronary angiography. PWV index and severity of CAD were positively correlated (P=0.001). All patients with obstructive CAD had a positive PWV index. When considering the PWV index retrospectively, the false positive results of cardiac stress test were significantly reduced (P<0.001). Twenty-three procedures may have been avoided in the present study cohort. The salient finding of this study was that in patients with known or suspected CAD, routinely followed aortic PWV index may be considered clinically useful for reducing the rate of unnecessary invasive angiographies. The clinical relevance of this individualized decision approach should be confirmed in a large-scale study. Prospective studies have the potential to evaluate the PWV index as a marker of CAD.
Won, Ki-Bum; Kim, Yun Seok; Lee, Byoung Kwon; Heo, Ran; Han, Donghee; Lee, Ji Hyun; Lee, Sang-Eun; Sung, Ji Min; Cho, Iksung; Park, Hyung-Bok; Cho, In-Jeong; Chang, Hyuk-Jae
2018-05-01
The triglyceride glucose (TyG) index is a useful surrogate marker for insulin resistance, which is an important risk factor for coronary artery disease (CAD). However, data on the relationship of the TyG index and coronary plaque characteristics are limited.This study included 2840 participants with near-normal renal function who underwent coronary computed tomography angiography. CAD was defined as the presence of any plaques, and obstructive CAD was defined as the presence of plaques with ≥50% stenosis. The relationship between the TyG index and noncalcified plaque (NCP), calcified or mixed plaque (CMP), and coronary artery calcium score (CACS) was evaluated.All participants were stratified into 4 groups based on the quartiles of the TyG index. The prevalence of CAD and obstructive CAD significantly increased with increasing quartiles. The risk for NCP and obstructive NCP was not different among all groups. However, compared with group I (lowest quartile), the risk for CMP was higher in groups III (odds ratio [OR]: 1.438) and IV (highest quartile) (OR: 1.895) (P < .05), and that for obstructive CMP was higher in groups II (OR: 1.469), III (OR: 1.595), and IV (OR: 2.168) (P < .05). Multivariate regression analysis showed that the TyG index was associated with an increased risk for CAD (OR: 1.700), obstructive CAD (OR: 1.692), and CACS >400 (OR: 1.448) (P < .05).The TyG index was independently associated with the presence and severity of CAD due to an increased risk for CMP.
CAD-design, stress analysis and in vitro evaluation of three leaflet blood-pump valves.
Knierbein, B; Rosarius, N; Unger, A; Reul, H; Rau, G
1992-07-01
The computer-supported development of valves for cardiac-assist devices or artificial hearts is shown in relation to plastic technology. A CAD-system is used for the design development, whereas the dimensioning of the critical and highly stressed membranes is examined by FEM-analyses. Economic manufacture is permitted by the combined thermoforming-dip moulding technique; the blood-side components are made from biocompatible polyurethane to minimize blood damage. The first long-term results in the test set-up are compared to the FEM results.
Taguchi, Masayuki; Namikawa, Kazuhiko; Maruo, Takuya; Orito, Kensuke; Lynch, Jonathan; Tsuchiya, Ryo; Sahara, Hiroeki
2012-08-01
Domesticated adult dogs with antibody titer classified as below 'high' to one or more of canine distemper virus (CDV), canine parvovirus type-2 (CPV-2) and canine adenovirus type-1 (CAdV-1) were then given an additional inoculation, and the effectiveness of this booster evaluated 2 months later. Consequently, CDV and CAdV-1 antibody titer experienced a significant increase, but the same effect was not observed in the antibody titer of CPV-2. These findings suggest that with additional inoculation, a booster effect may be expected in increasing antibody titers for CDV and CAdV-1, but it is unlikely to give an increase in CPV-2 antibody titer. © 2012 The Societies and Blackwell Publishing Asia Pty Ltd.
Noninvasive physiologic assessment of coronary stenoses using cardiac CT.
Xu, Lei; Sun, Zhonghua; Fan, Zhanming
2015-01-01
Coronary CT angiography (CCTA) has become an important noninvasive imaging modality in the diagnosis of coronary artery disease (CAD). CCTA enables accurate evaluation of coronary artery stenosis. However, CCTA provides limited information on the physiological significance of stenotic lesions. A noninvasive "one-stop-shop" diagnostic test that can provide both anatomical significance and functional significance of stenotic lesions would be beneficial in the diagnosis and management of CAD. Recently, with the introduction of novel techniques, such as myocardial CT perfusion, CT-derived fractional flow reserve (FFRCT), and transluminal attenuation gradient (TAG), CCTA has emerged as a noninvasive method for the assessment of both anatomy of coronary lesions and its physiological consequences during a single study. This review provides an overview of the current status of new CT techniques for the physiologic assessments of CAD.
Wireless remote monitoring of myocardial ischemia using reconstructed 12-lead ECGs.
Vukcevic, Vladan; Panescu, Dorin; Bojovic, Bosko; George, Samuel; Gussak, Ihor; Giga, Vojislav; Stankovic, Ivana
2010-01-01
CardioBip (CB) is a hand-held patient-activated device for recording and wireless transmission of reconstructed 12-lead ECG (12CB) based on patient specific matrices. It has 5 contact points: 3 precordial and 2 on the device top serving as limb leads when touched by index fingers. To determine whether CB could be used to monitor coronary disease (CAD) patients, we compared 12CB to simultaneous 12-lead ECGs (12L) in patients with CAD, pre-and post-exercise treadmill testing (ETT). The study goals were to assess: (1) whether 12CB can accurately reconstruct and wirelessly transmit 12-lead ECGs in CAD patients during ETT recovery; (2) whether 12CB can be used to evaluate ST segment changes in patients with exercise-induced ischemia.
Taqueti, Viviany R.; Di Carli, Marcelo F.
2018-01-01
Over the last several decades, radionuclide myocardial perfusion imaging (MPI) with single photon emission tomography and positron emission tomography has been a mainstay for the evaluation of patients with known or suspected coronary artery disease (CAD). More recently, technical advances in separate and complementary imaging modalities including coronary computed tomography angiography, computed tomography perfusion, cardiac magnetic resonance imaging, and contrast stress echocardiography have expanded the toolbox of diagnostic testing for cardiac patients. While the growth of available technologies has heralded an exciting era of multimodality cardiovascular imaging, coordinated and dispassionate utilization of these techniques is needed to implement the right test for the right patient at the right time, a promise of “precision medicine.” In this article, we review the maturing role of MPI in the current era of multimodality cardiovascular imaging, particularly in the context of recent advances in myocardial blood flow quantitation, and as applied to the evaluation of patients with known or suspected CAD. PMID:25770849
NASA Astrophysics Data System (ADS)
B. Shokouhi, Shahriar; Fooladivanda, Aida; Ahmadinejad, Nasrin
2017-12-01
A computer-aided detection (CAD) system is introduced in this paper for detection of breast lesions in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). The proposed CAD system firstly compensates motion artifacts and segments the breast region. Then, the potential lesion voxels are detected and used as the initial seed points for the seeded region-growing algorithm. A new and robust region-growing algorithm incorporating with Fuzzy C-means (FCM) clustering and vesselness filter is proposed to segment any potential lesion regions. Subsequently, the false positive detections are reduced by applying a discrimination step. This is based on 3D morphological characteristics of the potential lesion regions and kinetic features which are fed to the support vector machine (SVM) classifier. The performance of the proposed CAD system is evaluated using the free-response operating characteristic (FROC) curve. We introduce our collected dataset that includes 76 DCE-MRI studies, 63 malignant and 107 benign lesions. The prepared dataset has been used to verify the accuracy of the proposed CAD system. At 5.29 false positives per case, the CAD system accurately detects 94% of the breast lesions.
van Werkhoven, J M; Gaemperli, O; Schuijf, J D; Jukema, J W; Kroft, L J; Leschka, S; Alkadhi, H; Valenta, I; Pundziute, G; de Roos, A; van der Wall, E E; Kaufmann, P A; Bax, J J
2009-10-01
To assess whether multislice computed tomography coronary angiography (MSCTA) may be useful for risk stratification of patients with suspected coronary artery disease (CAD) at intermediate pretest likelihood according to Diamond and Forrester. MSCTA images were evaluated for the presence of significant CAD in 316 patients with suspected CAD (60% male, average (SD) age 57 (11) years) and an intermediate pretest likelihood according to Diamond and Forrester. Patients were followed up to determine the occurrence of an event. A combined end point of all-cause mortality, non-fatal infarction and unstable angina requiring revascularisation. Significant CAD was seen in 89 patients (28%), whereas normal MSCTA or non-significant CAD was seen in the remaining 227 (72%) patients. During follow-up (median 621 days (25-75th centile 408-835) an event occurred in 13 patients (4.8%). The annualised event rate was 0.8% in patients with normal MSCT, 2.2% in patients with non-significant CAD and 6.5% in patients with significant CAD. Moreover, MSCTA remained a significant predictor (p<0.05) of events after multivariate correction (hazard ratio = 3.460 (95% CI 1.142 to 10.480). The results suggest that in patients with an intermediate pretest likelihood, MSCTA is highly effective in re-stratifying patients into either a low or high post-test risk group. These results further emphasise the usefulness of non-invasive imaging with MSCTA in this patient population.
The effect of milling and postmilling procedures on the surface roughness of CAD/CAM materials.
Mota, Eduardo Gonçalves; Smidt, Laura Nunes; Fracasso, Lisiane Martins; Burnett, Luiz Henrique; Spohr, Ana Maria
2017-11-12
The aim of this study was to evaluate the surface roughness and analyze the surface topography of five different CAD/CAM ceramics and one CAD/CAM composite resin for CEREC after milling and postmilling procedures. Blocks of the ceramics Mark II, IPS Empress CAD, IPS e.max CAD, Suprinity and Enamic, and blocks of the composite resin Lava Ultimate were milled at CEREC MCXL. Ten flat samples of each material were obtained. The surface roughness (Ra) test was performed before and after milling, crystallization, polishing, and glaze when indicated, followed by SEM and AFM analysis. Data were submitted to one-way ANOVA with repeated measures and the Tukey HSD test (α = 0.05). The milling step significantly increased the roughness of all the tested materials (P < .05). Lithium-based ceramics (IPS e.max CAD and Suprinity) were more suitable to roughness than the other tested materials (P < .05). The polishing methods were able to reduce roughness to baseline values, except for lithium-based ceramics. Glaze reduced significantly the roughness of lithium-based ceramics without a difference from the baseline. SEM and AFM images revealed that glazed surfaces are smoother than polished surfaces. All hard-milling CAD/CAM materials, that is, fully sintered, should be only hand polished. The glaze step can be suppressed resulting in time saving. However, the glaze step in soft-milling lithium disilicate is imperative. © 2017 Wiley Periodicals, Inc.
Basso, G R; Moraes, R R; Borba, M; Griggs, J A; Della Bona, A
2015-12-01
To evaluate the flexural strength, Weibull modulus, fracture toughness, and failure behavior of ceramic structures obtained by the CAD-on technique, testing the null hypothesis that trilayer structures show similar properties to monolithic structures. Bar-shaped (1.8mm×4mm×16mm) monolithic specimens of zirconia (IPS e.max ZirCAD - Ivoclar Vivadent) and trilayer specimens of zirconia/fusion ceramic/lithium dissilicate (IPS e.max ZirCAD/IPS e.max CAD Crystall./Connect/IPS e.max CAD, Ivoclar Vivadent) were fabricated (n=30). Specimens were tested in flexure in 37°C deionized water using a universal testing machine at a crosshead speed of 0.5mm/min. Failure loads were recorded, and the flexural strength values were calculated. Fractography principles were used to examine the fracture surfaces under optical and scanning electron microscopy. Data were statistically analyzed using Student's t-test and Weibull statistics (α=0.05). Monolithic and trilayer specimens showed similar mean flexural strengths, characteristic strengths, and Weibull moduli. Trilayer structures showed greater mean critical flaw and fracture toughness values than monolithic specimens (p<0.001). Most critical flaws in the trilayer groups were located on the Y-TZP surface subjected to tension and propagated catastrophically. Trilayer structures showed no flaw deflection at the interface. Considering the CAD-on technique, the trilayer structures showed greater fracture toughness than the monolithic zirconia specimens. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Ben-Shoshan, Jeremy; Segman-Rosenstveig, Yafit; Arbel, Yaron; Chorin, Ehud; Barkagan, Michael; Rozenbaum, Zach; Granot, Yoav; Finkelstein, Ariel; Banai, Shmuel; Keren, Gad; Shacham, Yacov
2016-04-15
Various physical, emotional, and extrinsic triggers have been attributed to acute coronary syndrome. Whether a correlation can be drawn between identifiable ischemic triggers and the nature of coronary artery disease (CAD) still remains unclear. In the present study, we evaluated the correlation between triggered versus nontriggered ischemic symptoms and the extent of CAD in patients with ST-segment elevation myocardial infarction (STEMI). We conducted a retrospective, single-center observational study including 1,345 consecutive patients with STEMI, treated with primary percutaneous coronary intervention. Acute physical and emotional triggers were identified in patients' historical data. Independent predictors of multivessel CAD were determined using a logistic regression model. A potential trigger was identified in 37% of patients. Physical exertion was found to be the most dominant trigger (65%) followed by psychological stress (16%) and acute illness (12%). Patients with nontriggered STEMI tended to be older and more likely to have co-morbidities. Patients with nontriggered STEMI showed a higher rate of multivessel CAD (73% vs 30%, p <0.001). In a multivariate regression model, nontriggered symptoms emerged as an independent predictor of multivessel CAD (odds ratio 8.33, 95% CI 5.74 to 12.5, p = 0.001). No specific trigger was found to predict independently the extent of CAD. In conclusion, symptoms onset without a recognizable trigger is associated with multivessel CAD in STEMI. Further studies will be required to elucidate the putative mechanisms underlying ischemic triggering. Copyright © 2016 Elsevier Inc. All rights reserved.
Non-invasive assessment of low- and intermediate-risk patients with chest pain
Balfour, Pelbreton C.; Gonzalez, Jorge A.; Kramer, Christopher M.
2016-01-01
Coronary artery disease (CAD) remains a significant global public health burden despite advancements in prevention and therapeutic strategies. Common non-invasive imaging modalities, anatomic and functional, are available for the assessment of patients with stable chest pain. Exercise electrocardiography is a long-standing method for evaluation for CAD and remains the initial test for the majority of patients who can exercise adequately with a baseline interpretable electrocardiogram. The addition of cardiac imaging to exercise testing provides incremental benefit for accurate diagnosis for CAD and is particularly useful in patients who are unable to exercise adequately and/or have uninterpretable electrocardiograms. Radionuclide myocardial perfusion imaging and echocardiography with exercise or pharmacological stress provide high sensitivity and specificity in the detection and further risk stratification of patients with CAD. Recently, coronary computed tomography angiography has demonstrated its growing role to rule out significant CAD given its high negative predictive value. Although less available, stress cardiac magnetic resonance provides a comprehensive assessment of cardiac structure and function and provides a high diagnostic accuracy in the detection of CAD. The utilization of non-invasive testing is complex due to various advantages and limitations, particularly in the assessment of low- and intermediate-risk patients with chest pain, where no single study is suitable for all patients. This review will describe currently available non-invasive modalities, along with current evidence-based guidelines and appropriate use criteria in the assessment of low- and intermediate-risk patients with suspected, stable CAD. PMID:27717538
Computer aided detection of clusters of microcalcifications on full field digital mammograms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ge Jun; Sahiner, Berkman; Hadjiiski, Lubomir M.
2006-08-15
We are developing a computer-aided detection (CAD) system to identify microcalcification clusters (MCCs) automatically on full field digital mammograms (FFDMs). The CAD system includes six stages: preprocessing; image enhancement; segmentation of microcalcification candidates; false positive (FP) reduction for individual microcalcifications; regional clustering; and FP reduction for clustered microcalcifications. At the stage of FP reduction for individual microcalcifications, a truncated sum-of-squares error function was used to improve the efficiency and robustness of the training of an artificial neural network in our CAD system for FFDMs. At the stage of FP reduction for clustered microcalcifications, morphological features and features derived from themore » artificial neural network outputs were extracted from each cluster. Stepwise linear discriminant analysis (LDA) was used to select the features. An LDA classifier was then used to differentiate clustered microcalcifications from FPs. A data set of 96 cases with 192 images was collected at the University of Michigan. This data set contained 96 MCCs, of which 28 clusters were proven by biopsy to be malignant and 68 were proven to be benign. The data set was separated into two independent data sets for training and testing of the CAD system in a cross-validation scheme. When one data set was used to train and validate the convolution neural network (CNN) in our CAD system, the other data set was used to evaluate the detection performance. With the use of a truncated error metric, the training of CNN could be accelerated and the classification performance was improved. The CNN in combination with an LDA classifier could substantially reduce FPs with a small tradeoff in sensitivity. By using the free-response receiver operating characteristic methodology, it was found that our CAD system can achieve a cluster-based sensitivity of 70, 80, and 90 % at 0.21, 0.61, and 1.49 FPs/image, respectively. For case-based performance evaluation, a sensitivity of 70, 80, and 90 % can be achieved at 0.07, 0.17, and 0.65 FPs/image, respectively. We also used a data set of 216 mammograms negative for clustered microcalcifications to further estimate the FP rate of our CAD system. The corresponding FP rates were 0.15, 0.31, and 0.86 FPs/image for cluster-based detection when negative mammograms were used for estimation of FP rates.« less
2012-01-01
Background Coronary artery calcifications (CAC) are markers of coronary atherosclerosis, but do not correlate well with stenosis severity. This study intended to evaluate clinical situations where a combined approach of coronary calcium scoring (CS) and nuclear stress test (SPECT-MPI) is useful for the detection of relevant CAD. Methods Patients with clinical indication for invasive coronary angiography (ICA) were included into our study during 08/2005-09/2008. At first all patients underwent CS procedure as part of the study protocol performed by either using a multidetector computed tomography (CT) scanner or a dual-source CT imager. CAC were automatically defined by dedicated software and the Agatston score was semi-automatically calculated. A stress-rest SPECT-MPI study was performed afterwards and scintigraphic images were evaluated quantitatively. Then all patients underwent ICA. Thereby significant CAD was defined as luminal stenosis ≥75% in quantitative coronary analysis (QCA) in ≥1 epicardial vessel. To compare data lacking Gaussian distribution an unpaired Wilcoxon-Test (Mann–Whitney) was used. Otherwise a Students t-test for unpaired samples was applied. Calculations were considered to be significant at a p-value of <0.05. Results We consecutively included 351 symptomatic patients (mean age: 61.2±12.3 years; range: 18–94 years; male: n=240) with a mean Agatston score of 258.5±512.2 (range: 0–4214). ICA verified exclusion of significant CAD in 66/67 (98.5%) patients without CAC. CAC was detected in remaining 284 patients. In 132/284 patients (46.5%) with CS>0 significant CAD was confirmed by ICA, and excluded in 152/284 (53.5%) patients. Sensitivity for CAD detection by CS alone was calculated as 99.2%, specificity was 30.3%, and negative predictive value was 98.5%. An additional SPECT in patients with CS>0 increased specificity to 80.9% while reducing sensitivity to 87.9%. Diagnostic accuracy was 84.2%. Conclusions In patients without CS=0 significant CAD can be excluded with a high negative predictive value by CS alone. An additional SPECT-MPI in those patients with CS>0 leads to a high diagnostic accuracy for the detection of CAD while reducing the number of patients needing invasive diagnostic procedure. PMID:23206557
Comparison of denture base adaptation between CAD-CAM and conventional fabrication techniques.
Goodacre, Brian J; Goodacre, Charles J; Baba, Nadim Z; Kattadiyil, Mathew T
2016-08-01
Currently no data comparing the denture base adaptation of CAD-CAM and conventional denture processing techniques have been reported. The purpose of this in vitro study was to compare the denture base adaptation of pack and press, pour, injection, and CAD-CAM techniques for fabricating dentures to determine which process produces the most accurate and reproducible adaptation. A definitive cast was duplicated to create 40 gypsum casts that were laser scanned before any fabrication procedures were initiated. A master denture was made using the CAD-CAM process and was then used to create a putty mold for the fabrication of 30 standardized wax festooned dentures, 10 for each of the conventional processing techniques (pack and press, pour, injection). Scan files from 10 casts were sent to Global Dental Science, LLC for fabrication of the CAD-CAM test specimens. After specimens for each of the 4 techniques had been fabricated, they were hydrated for 24 hours and the intaglio surface laser scanned. The scan file of each denture was superimposed on the scan file of the corresponding preprocessing cast using surface matching software. Measurements were made at 60 locations, providing evaluation of fit discrepancies at the following areas: apex of the denture border, 6 mm from the denture border, crest of the ridge, palate, and posterior palatal seal. The use of median and interquartile range was used to assess accuracy and reproducibility. The Levine and Kruskal-Wallis analysis of variance was used to evaluate differences between processing techniques at the 5 specified locations (α=.05). The ranking of results based on median and interquartile range determined that the accuracy and reproducibility of the CAD-CAM technique was more consistently localized around zero at 3 of the 5 locations. Therefore, the CAD-CAM technique showed the best combination of accuracy and reproducibility among the tested fabrication techniques. The pack and press technique was more accurate at 2 of the 5 locations; however, its interquartile range (reproducibility) was the greatest of the 4 tested processing techniques. The pour technique was the most reproducible at 2 of the 5 locations; however, its accuracy was the lowest of the tested techniques. The CAD-CAM fabrication process was the most accurate and reproducible denture fabrication technique when compared with pack and press, pour, and injection denture base processing techniques. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Xie, Joe X; Cury, Ricardo C; Leipsic, Jonathon; Crim, Matthew T; Berman, Daniel S; Gransar, Heidi; Budoff, Matthew J; Achenbach, Stephan; Ó Hartaigh, Bríain; Callister, Tracy Q; Marques, Hugo; Rubinshtein, Ronen; Al-Mallah, Mouaz H; Andreini, Daniele; Pontone, Gianluca; Cademartiri, Filippo; Maffei, Erica; Chinnaiyan, Kavitha; Raff, Gilbert; Hadamitzky, Martin; Hausleiter, Joerg; Feuchtner, Gudrun; Dunning, Allison; DeLago, Augustin; Kim, Yong-Jin; Kaufmann, Philipp A; Villines, Todd C; Chow, Benjamin J W; Hindoyan, Niree; Gomez, Millie; Lin, Fay Y; Jones, Erica; Min, James K; Shaw, Leslee J
2018-01-01
This study sought to assess clinical outcomes associated with the novel Coronary Artery Disease-Reporting and Data System (CAD-RADS) scores used to standardize coronary computed tomography angiography (CTA) reporting and their potential utility in guiding post-coronary CTA care. Clinical decision support is a major focus of health care policies aimed at improving guideline-directed care. Recently, CAD-RADS was developed to standardize coronary CTA reporting and includes clinical recommendations to facilitate patient management after coronary CTA. In the multinational CONFIRM (COronary CT Angiography EvaluatioN For Clinical Outcomes: An InteRnational Multicenter) registry, 5,039 patients without known coronary artery disease (CAD) underwent coronary CTA and were stratified by CAD-RADS scores, which rank CAD stenosis severity as 0 (0%), 1 (1% to 24%), 2 (25% to 49%), 3 (50% to 69%), 4A (70% to 99% in 1 to 2 vessels), 4B (70% to 99% in 3 vessels or ≥50% left main), or 5 (100%). Kaplan-Meier and multivariable Cox models were used to estimate all-cause mortality or myocardial infarction (MI). Receiver-operating characteristic (ROC) curves were used to compare CAD-RADS to the Duke CAD Index and traditional CAD classification. Referrals to invasive coronary angiography (ICA) after coronary CTA were also assessed. Cumulative 5-year event-free survival ranged from 95.2% to 69.3% for CAD-RADS 0 to 5 (p < 0.0001). Higher scores were associated with elevations in event risk (hazard ratio: 2.46 to 6.09; p < 0.0001). The ROC curve for prediction of death or MI was 0.7052 for CAD-RADS, which was noninferior to the Duke Index (0.7073; p = 0.893) and traditional CAD classification (0.7095; p = 0.783). ICA rates were 13% for CAD-RADS 0 to 2, 66% for CAD-RADS 3, and 84% for CAD-RADS ≥4A. For CAD-RADS 3, 58% of all catheterizations occurred within the first 30 days of follow-up. In a patient subset with available medication data, 57% of CAD-RADS 3 patients who received 30-day ICA were either asymptomatic or not receiving antianginal therapy at baseline, whereas only 32% had angina and were receiving medical therapy. CAD-RADS effectively identified patients at risk for adverse events. Frequent ICA use was observed among patients without severe CAD, many of whom were asymptomatic or not taking antianginal drugs. Incorporating CAD-RADS into coronary CTA reports may provide a novel opportunity to promote evidence-based care post-coronary CTA. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Use of interactive graphics in bridge analysis and design.
DOT National Transportation Integrated Search
1983-01-01
This study evaluated the role of computer-aided design (CAD), including interactive graphics, in engineering design applications, especially in the design activities of the Virginia Department of Highways and Transportation. A review of the hardware ...
Riccitiello, Francesco; Amato, Massimo; Leone, Renato; Spagnuolo, Gianrico; Sorrentino, Roberto
2018-01-01
Prosthetic precision can be affected by several variables, such as restorative materials, manufacturing procedures, framework design, cementation techniques and aging. Marginal adaptation is critical for long-term longevity and clinical success of dental restorations. Marginal misfit may lead to cement exposure to oral fluids, resulting in microleakage and cement dissolution. As a consequence, marginal discrepancies enhance percolation of bacteria, food and oral debris, potentially causing secondary caries, endodontic inflammation and periodontal disease. The aim of the present in vitro study was to evaluate the marginal and internal adaptation of zirconia and lithium disilicate single crowns, produced with different manufacturing procedures. Forty-five intact human maxillary premolars were prepared for single crowns by means of standardized preparations. All-ceramic crowns were fabricated with either CAD-CAM or heat-pressing procedures (CAD-CAM zirconia, CAD-CAM lithium disilicate, heat-pressed lithium disilicate) and cemented onto the teeth with a universal resin cement. Non-destructive micro-CT scanning was used to achieve the marginal and internal gaps in the coronal and sagittal planes; then, precision of fit measurements were calculated in a dedicated software and the results were statistically analyzed. The heat-pressed lithium disilicate crowns were significantly less accurate at the prosthetic margins (p<0.05) while they performed better at the occlusal surface ( p <0.05). No significant differences were noticed between CAD-CAM zirconia and lithium disilicate crowns ( p >0.05); nevertheless CAD-CAM zirconia copings presented the best marginal fit among the experimental groups. As to the thickness of the cement layer, reduced amounts of luting agent were noticed at the finishing line, whereas a thicker layer was reported at the occlusal level. Within the limitations of the present in vitro investigation, the following conclusions can be drawn: the recorded marginal gaps were within the clinical acceptability irrespective of both the restorative material and the manufacturing procedures; the CAD-CAM processing techniques for both zirconia and lithium disilicate produced more consistent marginal gaps than the heat-pressing procedures; the tested universal resin cement can be safely used with both restorative materials.
Zimmermann, Moritz; Valcanaia, Andre; Neiva, Gisele; Mehl, Albert; Fasbinder, Dennis
2017-11-30
Several methods for the evaluation of fit of computer-aided design/computer-assisted manufacture (CAD/CAM)-fabricated restorations have been described. In the study, digital models were recorded with an intraoral scanning device and were measured using a new three-dimensional (3D) computer technique to evaluate restoration internal fit. The aim of the study was to evaluate the internal adaptation and fit of chairside CAD/CAM-fabricated zirconia-reinforced lithium silicate ceramic crowns fabricated with different post-milling protocols. The null hypothesis was that different post-milling protocols did not influence the fitting accuracy of zirconia-reinforced lithium silicate restorations. A master all-ceramic crown preparation was completed on a maxillary right first molar on a typodont. Twenty zirconia-reinforced lithium silicate ceramic crowns (Celtra Duo, Dentsply Sirona) were designed and milled using a chairside CAD/CAM system (CEREC Omnicam, Dentsply Sirona). The 20 crowns were randomly divided into two groups based on post-milling protocols: no manipulation after milling (Group MI) and oven fired-glazing after milling (Group FG). A 3D computer method was used to evaluate the internal adaptation of the crowns. This was based on a subtractive analysis of a digital scan of the crown preparation and a digital scan of the thickness of the cement space over the crown preparation as recorded by a polyvinylsiloxane (PVS) impression material. The preparation scan and PVS scan were matched in 3D and a 3D difference analysis was performed with a software program (OraCheck, Cyfex). Three areas of internal adaptation and fit were selected for analysis: margin (MA), axial wall (AX), and occlusal surface (OC). Statistical analysis was performed using 80% percentile and one-way ANOVA with post-hoc Scheffé test (P = .05). The closest internal adaptation of the crowns was measured at the axial wall with 102.0 ± 11.7 µm for group MI-AX and 106.3 ± 29.3 µm for group FG-AX. The largest internal adaptation of the crowns was measured for the occlusal surface with 258.9 ± 39.2 µm for group MI-OC and 260.6 ± 55.0 µm for group FG-OC. No statistically significant differences were found for the post-milling protocols (P > .05). The 3D difference pattern was visually analyzed for each area with a color-coded scheme. Post-milling processing did not affect the internal adaptation of zirconia-reinforced lithium silicate crowns fabricated with a chairside CAD/CAM technique. The new 3D computer technique for the evaluation of fit of restorations may be highly promising and has the opportunity to be applied to clinical studies.
Greulich, Simon; Steubing, Hannah; Birkmeier, Stefan; Grün, Stefan; Bentz, Kerstin; Sechtem, Udo; Mahrholdt, Heiko
2015-11-05
The diagnostic performance of adenosine stress cardiovascular magnetic resonance (CMR) in patients with arrhythmias presenting for work-up of suspected or known CAD is largely unknown, since most CMR studies currently available exclude arrhythmic patients from analysis fearing gating problems, or other artifacts will impair image quality. The primary aim of our study was to evaluate the diagnostic performance of adenosine stress CMR for detection of significant coronary stenosis in patients with arrhythmia presenting for 1) work-up of suspected coronary artery disease (CAD), or 2) work-up of ischemia in known CAD. Patients with arrhythmia referred for work-up of suspected CAD or work-up of ischemia in known CAD undergoing adenosine stress CMR were included if they had coronary angiography within four weeks of CMR. One hundred fifty-nine patients were included (n = 64 atrial fibrillation, n = 87 frequent ventricular extrasystoles, n = 8 frequent supraventricular extrasystoles). Of these, n = 72 had suspected CAD, and n = 87 had known CAD. Diagnostic accuracy of the adenosine stress CMR for detection of significant CAD was 73 % for the entire population (sensitivity 72 %, specificity 76 %). Diagnostic accuracy was 75 % (sensitivity 80 %, specificity 74 %) in patients with suspected CAD, and 74 % (sensitivity 71 %, specificity 79 %) in the group with known CAD. For different types of arrhythmia, diagnostic accuracy of CMR was 70 % in the atrial fibrillation group, and 79 % in patients with ventricular extrasystoles. On a per coronary territory analysis, diagnostic accuracy of CMR was 77 % for stenosis of the left and 82 % for stenosis of the right coronary artery. The present data demonstrates good diagnostic performance of adenosine stress CMR for detection of significant coronary stenosis in patients with arrhythmia presenting for work-up of suspected CAD, or work-up of ischemia in known CAD. This holds true for a per patient, as well as for a per coronary territory analysis.
Planer, David; Mehran, Roxana; Ohman, E Magnus; White, Harvey D; Newman, Jonathan D; Xu, Ke; Stone, Gregg W
2014-06-01
Troponin elevation is a risk factor for mortality in patients with non-ST-segment-elevation acute coronary syndromes. However, the prognosis of patients with troponin elevation and nonobstructive coronary artery disease (CAD) is unknown. Our objective was therefore to evaluate the impact of nonobstructive CAD in patients with non-ST-segment-elevation acute coronary syndromes and troponin elevation enrolled in the Acute Catheterization and Urgent Intervention Triage Strategy (ACUITY) trial. In the ACUITY trial, 3-vessel quantitative coronary angiography was performed in a formal substudy of 6921 patients presenting with non-ST-segment-elevation acute coronary syndromes. Patients with elevated admission troponin levels were stratified by the presence or absence of obstructive CAD (any lesion with quantitative diameter stenosis >50%). Propensity score matching was performed to adjust for baseline characteristics. Of 2442 patients with elevated troponin, 197 (8.8%) had nonobstructive CAD. Maximum diameter stenosis was 87.4 (73.2, 100.0) versus 22.6 (19.2, 25.7; P<0.0001) in patients with versus without obstructive CAD, respectively. Propensity matching yielded 117 patients with nonobstructive CAD and 331 patients with obstructive CAD, with no significant baseline differences between groups. In the matched cohort, overall 1-year mortality was significantly higher in patients with nonobstructive CAD (5.2% versus 1.6%; hazard ratio [95% confidence interval]=3.44 [1.05, 11.28]; P=0.04), driven by greater noncardiac mortality. Conversely, recurrent myocardial infarction and unplanned revascularization rates were significantly higher in patients with obstructive CAD. Patients with non-ST-segment-elevation acute coronary syndromes and elevated troponin levels but without obstructive CAD, while having low rates of subsequent myocardial infarction and unplanned revascularization, are still at considerable risk for 1-year mortality from noncardiac causes. http://www.clinicaltrials.gov. Unique identifier: NCT00093158. © 2014 American Heart Association, Inc.
Gold, Marshall; Dunn, Laura B.; Phoenix, Bethany; Paul, Steven M.; Hamolsky, Deborah; Levine, Jon D.; Miaskowski, Christine
2015-01-01
Purpose Little is known about the prevalence of combined anxiety and depressive symptoms (CADS) in breast cancer patients. Purpose was to evaluate for differences in demographic and clinical characteristics and quality of life (QOL) prior to breast cancer surgery among women classified into one of four distinct anxiety and/or depressive symptom groups. Methods A total of 335 patients completed measures of anxiety and depressive symptoms and QOL prior to and for 6 months following breast cancer surgery. Growth Mixture Modelling (GMM) was used to identify subgroups of women with distinct trajectories of anxiety and depressive symptoms. These results were used to create four distinct anxiety and/or depressive symptom groups. Differences in demographic, clinical, and symptom characteristics, among these groups were evaluated using analyses of variance and Chi square analyses. Results A total of 44.5% of patients were categorized with CADS. Women with CADS were younger, non-white, had lower performance status, received neoadjuvant or adjuvant chemotherapy, had greater difficulty dealing with their disease and treatment, and reported less support from others to meet their needs. These women had lower physical, psychological, social well-being, and total QOL scores. Higher levels of anxiety with or without subsyndromal depressive symptoms were associated with increased fears of recurrence, hopelessness, uncertainty, loss of control, and a decrease in life satisfaction. Conclusions Findings suggest that CADS occurs in a high percentage of women following breast cancer surgery and results in a poorer QOL. Assessments of anxiety and depressive symptoms are warranted prior to surgery for breast cancer. PMID:26187660
Gold, Marshall; Dunn, Laura B; Phoenix, Bethany; Paul, Steven M; Hamolsky, Deborah; Levine, Jon D; Miaskowski, Christine
2016-02-01
Little is known about the prevalence of combined anxiety and depressive symptoms (CADS) in breast cancer patients. Purpose was to evaluate for differences in demographic and clinical characteristics and quality of life (QOL) prior to breast cancer surgery among women classified into one of four distinct anxiety and/or depressive symptom groups. A total of 335 patients completed measures of anxiety and depressive symptoms and QOL prior to and for 6 months following breast cancer surgery. Growth Mixture Modelling (GMM) was used to identify subgroups of women with distinct trajectories of anxiety and depressive symptoms. These results were used to create four distinct anxiety and/or depressive symptom groups. Differences in demographic, clinical, and symptom characteristics, among these groups were evaluated using analyses of variance and Chi square analyses. A total of 44.5% of patients were categorized with CADS. Women with CADS were younger, non-white, had lower performance status, received neoadjuvant or adjuvant chemotherapy, had greater difficulty dealing with their disease and treatment, and reported less support from others to meet their needs. These women had lower physical, psychological, social well-being, and total QOL scores. Higher levels of anxiety with or without subsyndromal depressive symptoms were associated with increased fears of recurrence, hopelessness, uncertainty, loss of control, and a decrease in life satisfaction. Findings suggest that CADS occurs in a high percentage of women following breast cancer surgery and results in a poorer QOL. Assessments of anxiety and depressive symptoms are warranted prior to surgery for breast cancer. Copyright © 2015 Elsevier Ltd. All rights reserved.
Chin, Shih-Jan; Wilde, Frank; Neuhaus, Michael; Schramm, Alexander; Gellrich, Nils-Claudius; Rana, Majeed
2017-12-01
The benefit of computer-assisted planning in orthognathic surgery has been extensively documented over the last decade. This study aims to evaluate the accuracy of a virtual orthognathic surgical plan by a novel three dimensional (3D) analysis method. Ten patients who required orthognathic surgery were included in this study. A virtual surgical plan was achieved by the combination of a 3D skull model acquired from computed tomography (CT) and surface scanning of the upper and lower dental arch respectively and final occlusal position. Osteotomies and movement of maxilla and mandible were simulated by Dolphin Imaging 11.8 Premium ® (Dolphin Imaging and Management Solutions, Chatsworth, CA). The surgical plan was transferred to surgical splints fabricated by means of Computer Aided Design/Computer Aided Manufacturing (CAD/CAM). Differences of three dimensional measurements between the virtual surgical plan and postoperative results were evaluated. The results from all parameters showed that the virtual surgical plans were successfully transferred by the assistance of CAD/CAM fabricated surgical splint. Wilcoxon's signed rank test showed that no statistically significant deviation between surgical plan and post-operational result could be detected. However, deviation of angle U1 axis-HP and distance of A-CP could not fulfill the clinical success criteria. Virtual surgical planning and CAD/CAM fabricated surgical splint are proven to facilitate treatment planning and offer an accurate surgical result in orthognathic surgery. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Tacoy, Gulten A; Yazici, Guliz E; Kocaman, Sinan A; Ozdemir, Murat H
2009-06-01
To investigate the thrombolysis in myocardial infarction (TIMI) frame count (TFC) in the coronary arteries without visible atherosclerosis in coronary angiography of patients with stable coronary artery disease (CAD). Eighty-three patients (mean age 58+/-10, 31 [37%] males), who underwent coronary angiographic evaluation for stable angina in Gazi University, Ankara, Turkey, Cardiology clinic between 2006-2007 were enrolled. Forty patients with normal coronary arteries were defined as group I. Group II consisted of 43 patients, who have one normal coronary artery in the setting of stable CAD defined as stenoses 50% or greater in at least one major coronary artery. Coronary blood flow and microvascular perfusion was evaluated by TFC. In group II, the TFC of left anterior descending artery (LAD) in 15 patients, TFC of circumflex artery (CX) in 18 patient, and TFC of right coronary artery (RCA) in 10 patients were evaluated. In group II, the TFC of LAD (37+/-12 versus 29+/-12, p=0.015) and CX (22+/-8 versus 18+/-9, p=0.035) were significantly higher than those in group I. The TFC of RCA was similar between groups (17+/-9 versus 17+/-8, p=0.990). After the adjustment of the risk factors by multivariate regression analyses, the association between TFC and clinical characteristic was statistically non-significant. The TFC decreased in angiographically normal LAD and CX arteries in the setting of stable angina pectoris. The important predictor was CAD alone, irrespective of the clinical parameters.
Fu, Guangzhen; Hu, Mei; Chu, Lina; Zhang, Man
2015-01-01
Objectives. We aim to explore urinary biomarkers that could monitor CAD in type 2 diabetic patients. Materials and Methods. Urine samples from two groups, twenty-eight type 2 diabetic patients with coexisting CAD and thirty type 2 diabetic patients without CAD, were purified by MB-WCX and then analyzed by MALDI-TOF-MS. Subsequently, we compared the urinary peptide signatures of the two groups by use of ClinProTools2.1 and evaluated the potential ability of the differently expressed peptides to distinguish type 2 diabetic patients with coexisting CAD from type 2 diabetic patients without CAD by ROC analysis. Finally, the differently expressed peptides were identified by nanoliquid chromatography-tandem mass spectrometry. Results. There were six differently expressed peptides (m/z 1305.2, 1743.9, 2184.9, 2756.1, 3223.2, and 6196.1) between the two groups of subjects, and they were identified as fragments of isoform 1 of fibrinogen alpha chain precursor, prothrombin precursor, and interalpha-trypsin inhibitor heavy chain H4. The diagnostic efficacy of m/z 2756.1 and m/z 3223.2 was better than the other peptides. Area under ROC of the m/z 2756.1, and m/z 3223.2 was 0.98 and 0.93, respectively. Conclusions. These urinary peptides are potential urinary biomarkers for monitoring of type 2 diabetic patients with CAD. PMID:26089891
Berthiaume, John T; Davis, Jim; Taira, Deborah A; Thein, Ko Ko
2007-03-01
To evaluate the effect of a managed care organization's multifactorial intervention program in optimizing secondary prevention of coronary artery disease (CAD). Retrospective observational analysis of claims-based data of health plan members with CAD receiving 1 or more prescriptions per year of any of the following classes of medications used for secondary prevention of CAD: lipid-lowering agents, angiotensin-converting enzyme (ACE) inhibitors, or angiotensin receptor blockers (ARBs) and beta-blockers. Claims-based data of members from 2000 to 2004 were analyzed to discover trends in the use of medications for secondary prevention of CAD. chi(2) Test of proportion was used to determine whether the changes in the annual medication use rates were statistically significant. The annual medication use rates improved consistently throughout each year of the study period. From 2000 to 2004, the medication use rates increased for lipid-lowering agents (from 55% to 71%), ACE inhibitors or ARBs (from 44% to 55%), and beta-blockers (from 36% to 47%). Changes in all 3 indicators were statistically significant at P < .001. An integrated multifactorial approach is essential in addressing the underutilization of therapies available for secondary prevention of CAD. Managed care organizations are in a unique position to optimize the use of evidence-based pharmacological and behavioral therapies to effectively prevent and treat the underlying pathophysiology of CAD in member populations.
Zucuni, C P; Guilardi, L F; Fraga, S; May, L G; Pereira, G K R; Valandro, L F
2017-07-01
This study evaluated the effects of different pre-sintering fabrication processing techniques of Y-TZP ceramic (CAD/CAM Vs. in-lab), considering surface characteristics and mechanical performance outcomes. Pre-sintered discs of Y-TZP ceramic (IPS e.max ZirCAD, Ivoclar Vivadent) were produced using different pre-sintering fabrication processing techniques: Machined- milling with a CAD/CAM system; Polished- fabrication using a cutting device followed by polishing (600 and 1200 SiC papers); Xfine- fabrication using a cutting machine followed by grinding with extra-fine diamond bur (grit size 30 μm); Fine- fabrication using a cutting machine followed by grinding with fine diamond bur (grit size 46 μm); SiC- fabrication using a cutting machine followed by grinding with 220 SiC paper. Afterwards, the discs were sintered and submitted to roughness (n=35), surface topography (n=2), phase transformation (n=2), biaxial flexural strength (n=20), and biaxial flexural fatigue strength (fatigue limit) (n=15) analyses. No monoclinic-phase content was observed in all processing techniques. It can be observed that obtaining a surface with similar characteristics to CAD/CAM milling is essential for the observation of similar mechanical performance. On this sense, grinding with fine diamond bur before sintering (Fine group) was the best mimic protocol in comparison to the CAD/CAM milling. Copyright © 2017 Elsevier Ltd. All rights reserved.
Web-based computer-aided-diagnosis (CAD) system for bone age assessment (BAA) of children
NASA Astrophysics Data System (ADS)
Zhang, Aifeng; Uyeda, Joshua; Tsao, Sinchai; Ma, Kevin; Vachon, Linda A.; Liu, Brent J.; Huang, H. K.
2008-03-01
Bone age assessment (BAA) of children is a clinical procedure frequently performed in pediatric radiology to evaluate the stage of skeletal maturation based on a left hand and wrist radiograph. The most commonly used standard: Greulich and Pyle (G&P) Hand Atlas was developed 50 years ago and exclusively based on Caucasian population. Moreover, inter- & intra-observer discrepancies using this method create a need of an objective and automatic BAA method. A digital hand atlas (DHA) has been collected with 1,400 hand images of normal children from Asian, African American, Caucasian and Hispanic descends. Based on DHA, a fully automatic, objective computer-aided-diagnosis (CAD) method was developed and it was adapted to specific population. To bring DHA and CAD method to the clinical environment as a useful tool in assisting radiologist to achieve higher accuracy in BAA, a web-based system with direct connection to a clinical site is designed as a novel clinical implementation approach for online and real time BAA. The core of the system, a CAD server receives the image from clinical site, processes it by the CAD method and finally, generates report. A web service publishes the results and radiologists at the clinical site can review it online within minutes. This prototype can be easily extended to multiple clinical sites and will provide the foundation for broader use of the CAD system for BAA.
Effect of Home Bleaching on the Translucency of CAD/CAM Systems.
Karci, Muhammet; Demir, Necla
2017-11-10
To evaluate the effect of a home bleaching agent (Opalescence PF) on the translucency of CAD/CAM ceramic systems. The 28 sintered ceramic specimens (IPS Empress CAD and IPS e.max CAD; 15 mm long, 10 mm wide, 1 mm thick) were divided into two subgroups as control and bleaching groups (n = 7). Carbamide peroxide (CP), 16%, home bleaching agent was applied onto the surface of each specimen for 6 hours per day for 7 days. A spectrophotometer (VITA Easyshade Advance) was used to measure the CIE L * a * b * coordinates and the reflectance value (Y) of the specimens on white and black backgrounds. The translucency parameter (TP), contrast ratio (CR), and opalescence parameter (OP) of the specimens were calculated. The data were statistically analyzed using Kolmogorov-Smirnov, one-way ANOVA, Tukey's test, and Pearson's correlation. Statistically significant differences in the TP values after 16% CP bleaching treatment were observed (p ˂ 0.05); however, no significant differences were found in the OP and CR values after the surface treatment (p ˃ 0.05). According to our study, patients who have all-ceramic restorations in their mouths should be careful when using home bleaching agents, because whitening agents can affect the translucency of all-ceramic restorations such as e.max CAD and Empress CAD. © 2017 by the American College of Prosthodontists.
Mazurowski, Maciej A; Zurada, Jacek M; Tourassi, Georgia D
2009-07-01
Ensemble classifiers have been shown efficient in multiple applications. In this article, the authors explore the effectiveness of ensemble classifiers in a case-based computer-aided diagnosis system for detection of masses in mammograms. They evaluate two general ways of constructing subclassifiers by resampling of the available development dataset: Random division and random selection. Furthermore, they discuss the problem of selecting the ensemble size and propose two adaptive incremental techniques that automatically select the size for the problem at hand. All the techniques are evaluated with respect to a previously proposed information-theoretic CAD system (IT-CAD). The experimental results show that the examined ensemble techniques provide a statistically significant improvement (AUC = 0.905 +/- 0.024) in performance as compared to the original IT-CAD system (AUC = 0.865 +/- 0.029). Some of the techniques allow for a notable reduction in the total number of examples stored in the case base (to 1.3% of the original size), which, in turn, results in lower storage requirements and a shorter response time of the system. Among the methods examined in this article, the two proposed adaptive techniques are by far the most effective for this purpose. Furthermore, the authors provide some discussion and guidance for choosing the ensemble parameters.
Schneebeli, Esther; Brägger, Urs; Scherrer, Susanne S; Keller, Andrea; Wittneben, Julia G; Hicklin, Stefan P
2017-07-01
The aim of this study was to assess and compare quality as well as economic aspects of CAD/CAM high strength ceramic three-unit FDP frameworks ordered from dental laboratories located in emerging countries and Switzerland. The master casts of six cases were sent to five dental laboratories located in Thailand (Bangkok), China (Peking and Shenzhen), Turkey (Izmir), and Switzerland (Bern). Each laboratory was using a different CAD/CAM system. The clinical fit of the frameworks was qualitatively assessed, and the thickness of the framework material, the connector height, the width, and the diameter were evaluated using a measuring sensor. The analysis of the internal fit of the frameworks was performed by means of a replica technique, whereas the inner and outer surfaces of the frameworks were evaluated for traces of postprocessing and damage to the intaglio surface with light and electronic microscopes. Groups (dental laboratories and cases) were compared for statistically significant differences using Mann-Whitney U-tests after Bonferroni correction. An acceptable clinical fit was found at 97.9% of the margins produced in laboratory E, 87.5% in B, 93.7% in C, 79.2% in A, and 62.5% in D. The mean framework thicknesses were not statistically significantly different for the premolar regions; however, for the molar area 4/8 of the evaluated sites were statistically significantly different. Circumference, surface, and width of the connectors produced in the different laboratories were statistically significantly different but not the height. There were great differences in the designs for the pontic and connector regions, and some of the frameworks would not be recommended for clinical use. Traces of heavy postprocessing were found in frameworks from some of the laboratories. The prices per framework ranged from US$177 to US$896. By ordering laboratory work in developing countries, a considerable price reduction was obtained compared to the price level in Switzerland. Despite the use of the standardized CAD/CAM chains of production in all laboratories, a large variability in the quality aspects, such as clinical marginal fit, connector and pontic design, as well as postprocessing traces was noted. Recommended sound handling of postprocessing was not applied in all laboratories. Dentists should be aware of the true and factitious advantages of CAD/CAM production chains and not lose control over the process. © 2015 by the American College of Prosthodontists.
Yalcin, Hulya; Valenta, Ines; Zhao, Min; Tahari, Abdel; Lu, Dai-Yin; Higuchi, Takahiro; Yalcin, Fatih; Kucukler, Nagehan; Soleimanifard, Yalda; Zhou, Yun; Pomper, Martin G; Abraham, Theodore P; Tsui, Ben; Lodge, Martin A; Schindler, Thomas H; Roselle Abraham, M
2018-01-22
Quantification of myocardial blood flow (MBF) by positron emission tomography (PET) is important for investigation of angina in hypertrophic cardiomyopathy (HCM). Several software programs exist for MBF quantification, but they have been mostly evaluated in patients (with normal cardiac geometry), referred for evaluation of coronary artery disease (CAD). Software performance has not been evaluated in HCM patients who frequently have hyperdynamic LV function, LV outflow tract (LVOT) obstruction, small LV cavity size, and variation in the degree/location of LV hypertrophy. We compared results of MBF obtained using PMod, which permits manual segmentation, to those obtained by FDA-approved QPET software which has an automated segmentation algorithm. 13 N-ammonia PET perfusion data were acquired in list mode at rest and during pharmacologic vasodilation, in 76 HCM patients and 10 non-HCM patients referred for evaluation of CAD (CAD group.) Data were resampled to create static, ECG-gated and 36-frame-dynamic images. Myocardial flow reserve (MFR) and MBF (in ml/min/g) were calculated using QPET and PMod softwares. All HCM patients had asymmetric septal hypertrophy, and 50% had evidence of LVOT obstruction, whereas non-HCM patients (CAD group) had normal wall thickness and ejection fraction. PMod yielded significantly higher values for global and regional stress-MBF and MFR than for QPET in HCM. Reasonably fair correlation was observed for global rest-MBF, stress-MBF, and MFR using these two softwares (rest-MBF: r = 0.78; stress-MBF: r = 0.66.; MFR: r = 0.7) in HCM patients. Agreement between global MBF and MFR values improved when HCM patients with high spillover fractions (> 0.65) were excluded from the analysis (rest-MBF: r = 0.84; stress-MBF: r = 0.72; MFR: r = 0.8.) Regionally, the highest agreement between PMod and QPET was observed in the LAD territory (rest-MBF: r = 0.82, Stress-MBF: r = 0.68) where spillover fraction was the lowest. Unlike HCM patients, the non-HCM patients (CAD group) demonstrated excellent agreement in MBF/MFR values, obtained by the two softwares, when patients with high spillover fractions were excluded (rest-MBF: r = 0.95; stress-MBF: r = 0.92; MFR: r = 0.95). Anatomic characteristics specific to HCM hearts contribute to lower correlations between MBF/MFR values obtained by PMod and QPET, compared with non-HCM patients. These differences indicate that PMod and QPET cannot be used interchangeably for MBF/MFR analyses in HCM patients.
Marginal Fit Comparison of CAD/CAM Crowns Milled from Two Different Materials.
Azarbal, Atousa; Azarbal, Mohsen; Engelmeier, Robert L; Kunkel, Thomas C
2018-06-01
To evaluate the marginal fit of CAD/CAM copings milled from hybrid ceramic (Vita Enamic) blocks and lithium disilicate (IPS e.max CAD) blocks, and to evaluate the effect of crystallization firing on the marginal fit of lithium disilicate copings. A standardized metal die with a 1-mm-wide shoulder finish line was imaged using the CEREC AC Bluecam. The coping was designed using CEREC 3 software. The design was used to fabricate 15 lithium disilicate and 15 hybrid ceramic copings. Design and milling were accomplished by one operator. The copings were seated on the metal die using a pressure clamp with a uniform pressure of 5.5 lbs. A Macroview Microscope (14×) was used for direct viewing of the marginal gap. Four areas were imaged on each coping (buccal, distal, lingual, mesial). Image analysis software was used to measure the marginal gaps in μm at 15 randomly selected points on each of the four surfaces. A total of 60 measurements were made per specimen. For lithium disilicate copings the measurements for marginal gap were made before and after crystallization firing. Data were analyzed using paired t-test and Kruskal-Wallis test. The overall mean difference in marginal gap between the hybrid ceramic and crystallized lithium disilicate copings was statistically significant (p < 0.01). Greater mean marginal gaps were measured for crystallized lithium disilicate copings. The overall mean difference in marginal gap before and after firing (precrystallized and crystallized lithium disilicate copings) showed an average of 62 μm increase in marginal gap after firing. This difference was also significant (p < 0.01). A significant difference exists in the marginal gap discrepancy when comparing hybrid ceramic and lithium disilicate CAD/CAM crowns. Also crystallization firing can result in a significant increase in the marginal gap of lithium disilicate CAD/CAM crowns. © 2017 by the American College of Prosthodontists.
Hulten, Edward; Goehler, Alexander; Bittencourt, Marcio Sommer; Bamberg, Fabian; Schlett, Christopher L; Truong, Quynh A; Nichols, John; Nasir, Khurram; Rogers, Ian S; Gazelle, Scott G; Nagurney, John T; Hoffmann, Udo; Blankstein, Ron
2013-09-01
Coronary computed tomographic angiography (cCTA) allows rapid, noninvasive exclusion of obstructive coronary artery disease (CAD). However, concern exists whether implementation of cCTA in the assessment of patients presenting to the emergency department with acute chest pain will lead to increased downstream testing and costs compared with alternative strategies. Our aim was to compare observed actual costs of usual care (UC) with projected costs of a strategy including early cCTA in the evaluation of patients with acute chest pain in the Rule Out Myocardial Infarction Using Computer Assisted Tomography I (ROMICAT I) study. We compared cost and hospital length of stay of UC observed among 368 patients enrolled in the ROMICAT I study with projected costs of management based on cCTA. Costs of UC were determined by an electronic cost accounting system. Notably, UC was not influenced by cCTA results because patients and caregivers were blinded to the cCTA results. Costs after early implementation of cCTA were estimated assuming changes in management based on cCTA findings of the presence and severity of CAD. Sensitivity analysis was used to test the influence of key variables on both outcomes and costs. We determined that in comparison with UC, cCTA-guided triage, whereby patients with no CAD are discharged, could reduce total hospital costs by 23% (P<0.001). However, when the prevalence of obstructive CAD increases, index hospitalization cost increases such that when the prevalence of ≥ 50% stenosis is >28% to 33%, the use of cCTA becomes more costly than UC. cCTA may be a cost-saving tool in acute chest pain populations that have a prevalence of potentially obstructive CAD <30%. However, increased cost would be anticipated in populations with higher prevalence of disease.
NASA Astrophysics Data System (ADS)
Wormanns, Dag; Fiebich, Martin; Saidi, Mustafa; Diederich, Stefan; Heindel, Walter
2001-05-01
The purpose of the study was to evaluate a computer aided diagnosis (CAD) workstation with automatic detection of pulmonary nodules at low-dose spiral CT in a clinical setting for early detection of lung cancer. Two radiologists in consensus reported 88 consecutive spiral CT examinations. All examinations were reviewed using a UNIX-based CAD workstation with a self-developed algorithm for automatic detection of pulmonary nodules. The algorithm was designed to detect nodules with at least 5 mm diameter. The results of automatic nodule detection were compared to the consensus reporting of two radiologists as gold standard. Additional CAD findings were regarded as nodules initially missed by the radiologists or as false positive results. A total of 153 nodules were detected with all modalities (diameter: 85 nodules <5mm, 63 nodules 5-9 mm, 5 nodules >= 10 mm). Reasons for failure of automatic nodule detection were assessed. Sensitivity of radiologists for nodules >=5 mm was 85%, sensitivity of CAD was 38%. For nodules >=5 mm without pleural contact sensitivity was 84% for radiologists at 45% for CAD. CAD detected 15 (10%) nodules not mentioned in the radiologist's report but representing real nodules, among them 10 (15%) nodules with a diameter $GREW5 mm. Reasons for nodules missed by CAD include: exclusion because of morphological features during region analysis (33%), nodule density below the detection threshold (26%), pleural contact (33%), segmentation errors (5%) and other reasons (2%). CAD improves detection of pulmonary nodules at spiral CT significantly and is a valuable second opinion in a clinical setting for lung cancer screening. Optimization of region analysis and an appropriate density threshold have a potential for further improvement of automatic nodule detection.
Metabolic Syndrome and Coronary Artery Disease in Ossabaw Compared with Yucatan Swine
Neeb, Zachary P; Edwards, Jason M; Alloosh, Mouhamad; Long, Xin; Mokelke, Eric A; Sturek, Michael
2010-01-01
Metabolic syndrome (MetS), a compilation of associated risk factors, increases the risk of type 2 diabetes and coronary artery disease (CAD, atherosclerosis), which can progress to the point of artery occlusion. Stents are the primary interventional treatment for occlusive CAD, and patients with MetS and hyperinsulinemia have increased restenosis. Because of its thrifty genotype, the Ossabaw pig is a model of MetS. We tested the hypothesis that, when fed high-fat diet, Ossabaw swine develop more features of MetS, greater native CAD, and greater stent-induced CAD than do Yucatan swine. Animals of each breed were divided randomly into 2 groups and fed 2 different calorie-matched diets for 40 wk: control diet (C) and high-fat, high-cholesterol atherogenic diet (H). A bare metal stent was placed in the circumflex artery, and pigs were allowed to recover for 3 wk. Characteristics of MetS, macrovascular and microvascular CAD, in-stent stenosis, and Ca2+ signaling in coronary smooth muscle cells were evaluated. MetS characteristics including, obesity, glucose intolerance, hyperinsulinemia, and elevated arterial pressure were elevated in Ossabaw swine compared to Yucatan swine. Ossabaw swine with MetS had more extensive and diffuse native CAD and in-stent stenosis and impaired coronary blood flow regulation compared with Yucatan. In-stent atherosclerotic lesions in Ossabaw coronary arteries were less fibrous and more cellular. Coronary smooth muscle cells from Ossabaw had impaired Ca2+ efflux and intracellular sequestration versus cells from Yucatan swine. Therefore, Ossabaw swine are a superior model of MetS, subsequent CAD, and cellular Ca2+ signaling defects, whereas Yucatan swine are leaner and relatively resistant to MetS and CAD. PMID:20819380
Belli, Renan; Wendler, Michael; de Ligny, Dominique; Cicconi, Maria Rita; Petschelt, Anselm; Peterlik, Herwig; Lohbauer, Ulrich
2017-01-01
A deeper understanding of the mechanical behavior of dental restorative materials requires an insight into the materials elastic constants and microstructure. Here we aim to use complementary methodologies to thoroughly characterize chairside CAD/CAM materials and discuss the benefits and limitations of different analytical strategies. Eight commercial CAM/CAM materials, ranging from polycrystalline zirconia (e.max ZirCAD, Ivoclar-Vivadent), reinforced glasses (Vitablocs Mark II, VITA; Empress CAD, Ivoclar-Vivadent) and glass-ceramics (e.max CAD, Ivoclar-Vivadent; Suprinity, VITA; Celtra Duo, Dentsply) to hybrid materials (Enamic, VITA; Lava Ultimate, 3M ESPE) have been selected. Elastic constants were evaluated using three methods: Resonant Ultrasound Spectroscopy (RUS), Resonant Beam Technique (RBT) and Ultrasonic Pulse-Echo (PE). The microstructures were characterized using Scanning Electron Microscopy (SEM), Energy Dispersive X-ray Spectroscopy (EDX), Raman Spectroscopy and X-ray Diffraction (XRD). Young's modulus (E), Shear modulus (G), Bulk modulus (B) and Poisson's ratio (ν) were obtained for each material. E and ν reached values ranging from 10.9 (Lava Ultimate) to 201.4 (e.max ZirCAD) and 0.173 (Empress CAD) to 0.47 (Lava Ultimate), respectively. RUS showed to be the most complex and reliable method, while the PE method the easiest to perform but most unreliable. All dynamic methods have shown limitations in measuring the elastic constants of materials showing high damping behavior (hybrid materials). SEM images, Raman spectra and XRD patterns were made available for each material, showing to be complementary tools in the characterization of their crystal phases. Here different methodologies are compared for the measurement of elastic constants and microstructural characterization of CAD/CAM restorative materials. The elastic properties and crystal phases of eight materials are herein fully characterized. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Alharbi, Amal; Ardu, Stefano; Bortolotto, Tissiana; Krejci, Ivo
2017-04-01
To evaluate the stain susceptibility of CAD/CAM blocks and direct composite after long term exposure to various staining agents. 40 disk-shaped samples were fabricated from each of nine materials; six CAD/CAM (Vitablocs Mark II, Paradigm MZ100, Experimental Vita Hybrid Ceramic, Vita Enamic, Experimental Kerr and Lava Ultimate) and three direct composites (Filtek Supreme, Venus Diamond and Filtek Silorane). Samples were randomly divided into five groups (n = 8) according to different staining solutions (distilled water, tea, red wine, coffee and artificial saliva). Initial L*a*b* values were assessed using a calibrated digital spectrophotometer. Specimens were immersed in staining solutions and stored in an incubator at 37 °C for 120 days. L*a*b* values were assessed again and color change (∆E) was calculated as difference between recorded L*a*b* values. ANOVA, and Duncan test were used to identify differences between groups (α = 0.05). Significant differences in ∆E values were detected between materials (p = 0.000). Among all staining solutions, the highest ∆E value was observed with red wine. The new CAD/CAM blocks (Vita Enamic, Vita Hybrid Ceramic and Lava Ultimate) showed the highest resistance to staining compared to the MZ100 composite resin blocks. Filtek Silorane, a direct composite, showed high stain resistance values compared to CAD/CAM materials and other direct composites. Ceramic and composite CAD/CAM blocks had lower staining susceptibility than methacrylate based direct composite. Staining susceptibility of the new resin based CAD/CAM materials Vita Enamic and Lava Ultimate was comparable to feldspathic ceramic blocks (Vitablocs Mark II). Filtek Silorane showed promising results that were comparable to some CAD/CAM blocks.
Alqahtani, Fawaz
2017-01-01
The purpose of this study was to determine the effect of two extraoral computer-aided design (CAD) and computer-aided manufacturing (CAM) systems, in comparison with conventional techniques, on the marginal fit of monolithic CAD/CAM lithium disilicate ceramic crowns. This is an in vitro interventional study. The study was carried out at the Department of Prosthodontics, School of Dentistry, Prince Sattam Bin Abdul-Aziz University, Saudi Arabia, from December 2015 to April 2016. A marginal gap of 60 lithium disilicate crowns was evaluated by scanning electron microscopy. In total, 20 pressable lithium disilicate (IPS e.max Press [Ivoclar Vivadent]) ceramic crowns were fabricated using the conventional lost-wax technique as a control group. The experimental all-ceramic crowns were produced based on a scan stone model and milled using two extraoral CAD/CAM systems: the Cerec group was fabricated using the Cerec CAD/CAM system, and the Trios group was fabricated using Trios CAD and milled using Wieland Zenotec CAM. One-way analysis of variance (ANOVA) and the Scheffe post hoc test were used for statistical comparison of the groups (α=0.05). The mean (±standard deviation) of the marginal gap of each group was as follows: the Control group was 91.15 (±15.35) µm, the Cerec group was 111.07 (±6.33) µm, and the Trios group was 60.17 (±11.09) µm. One-way ANOVA and the Scheffe post hoc test showed a statistically significant difference in the marginal gap between all groups. It can be concluded from the current study that all-ceramic crowns, fabricated using the CAD/CAM system, show a marginal accuracy that is acceptable in clinical environments. The Trios CAD group displayed the smallest marginal gap.
Shinawi, Lana Ahmed
2017-01-01
Background The application of computer-aided design computer-aided manufacturing (CAD CAM) technology in the fabrication of complete dentures, offers numerous advantages as it provides optimum fit and eliminates polymerization shrinkage of the acrylic base. Additionally, the porosity and surface roughness of CAD CAM resins is less compared to conventionally processed resins which leads to a decrease in the adhesion of bacteria on the denture base, which is associated with many conditions including halitosis and aspiration pneumonia in elderly denture wearers. Aim To evaluate the influence of tooth brushing with dentifrices on CAD CAM resin blocks in terms of abrasion resistance, surface roughness and scanning electron photomicrography. Methods This experimental study was carried out at the Faculty of Dentistry of King Abdulaziz University during 2016. A total of 40 rectangular shaped polymerized CAD CAM resin samples were subjected to 40.000 and 60.000 brushing strokes under a 200-gram vertical load simulating three years of tooth brushing strokes using commercially available denture cleaning dentifrice. Data were analyzed by SPSS version 20, using descriptive statistics and ANOVA. Results ANOVA test revealed a statistical significant weight loss of CAD CAM acrylic resin denture base specimens following 40.000 and 60.000 brushing strokes as well as a statistical significant change (p=0.0.5) in the surface roughness following brushing. The CAD CAM resin samples SEM baseline imaging revealed a relatively smooth homogenous surface, but following 40,000 and 60,000 brushing strokes, imaging displayed the presence of small scratches on the surface. Conclusion CAD CAM resin displayed a homogenous surface initially with low surface roughness that was significantly affected following simulating three years of manual brushing, but despite the significant weight loss, the findings are within the clinically acceptable limits. PMID:28713496
Paine, Nicola J; Bacon, Simon L; Pelletier, Roxanne; Arsenault, André; Diodati, Jean G; Lavoie, Kim L
2016-02-01
Women diagnosed with coronary artery disease (CAD) typically experience worse outcomes relative to men, possibly through diagnosis and treatment delays. Reasons for these delays may be influenced by mood and anxiety disorders, which are more prevalent in women and have symptoms (eg, palpitations and fatigue) that may be confounded with CAD. Our study examined sex differences in the association between mood and anxiety disorders and myocardial ischemia in patients with and without a CAD history presenting for exercise stress tests. A total of 2342 patients (women n=760) completed a single photon emission computed tomographic exercise stress test (standard Bruce Protocol) and underwent a psychiatric interview (The Primary Care Evaluation of Mental Disorders) to assess mood and anxiety disorders. Ischemia was assessed using single photon emission computed tomography, with odds ratio used to calculate the effect of sex and mood/anxiety on the presence of ischemia during stress testing by CAD history in a stratified analyses, adjusted for relevant covariates. There was a sex by anxiety interaction with ischemia in those without a CAD history (P=0.015): women with anxiety were more likely to exhibit ischemia during exercise than women without anxiety (odds ratio, 1.75; 95% confidence interval, 1.05-2.89). No significant effects were observed for men nor mood. Women with anxiety and no CAD history had higher rates of ischemia than women without anxiety. Results suggest that anxiety symptoms, many of which overlap with those of CAD, might mask CAD symptoms among women (but not men) and contribute to referral and diagnostic delays. Further research is needed to confirm this hypothesis. © 2016 American Heart Association, Inc.
Shinawi, Lana Ahmed
2017-05-01
The application of computer-aided design computer-aided manufacturing (CAD CAM) technology in the fabrication of complete dentures, offers numerous advantages as it provides optimum fit and eliminates polymerization shrinkage of the acrylic base. Additionally, the porosity and surface roughness of CAD CAM resins is less compared to conventionally processed resins which leads to a decrease in the adhesion of bacteria on the denture base, which is associated with many conditions including halitosis and aspiration pneumonia in elderly denture wearers. To evaluate the influence of tooth brushing with dentifrices on CAD CAM resin blocks in terms of abrasion resistance, surface roughness and scanning electron photomicrography. This experimental study was carried out at the Faculty of Dentistry of King Abdulaziz University during 2016. A total of 40 rectangular shaped polymerized CAD CAM resin samples were subjected to 40.000 and 60.000 brushing strokes under a 200-gram vertical load simulating three years of tooth brushing strokes using commercially available denture cleaning dentifrice. Data were analyzed by SPSS version 20, using descriptive statistics and ANOVA. ANOVA test revealed a statistical significant weight loss of CAD CAM acrylic resin denture base specimens following 40.000 and 60.000 brushing strokes as well as a statistical significant change (p=0.0.5) in the surface roughness following brushing. The CAD CAM resin samples SEM baseline imaging revealed a relatively smooth homogenous surface, but following 40,000 and 60,000 brushing strokes, imaging displayed the presence of small scratches on the surface. CAD CAM resin displayed a homogenous surface initially with low surface roughness that was significantly affected following simulating three years of manual brushing, but despite the significant weight loss, the findings are within the clinically acceptable limits.
TNF-alpha-308G>A polymorphism and the risk of familial CAD in a Pakistani population.
Hussain, Sabir; Iqbal, Tahir; Javed, Qamar
2015-01-01
A case-control and trio-families study was performed to establish a potential association between TNF-alpha gene promoter SNPs at -308 and -238, and occurrence of CAD in a Pakistani population. In the first phase, 150 patients and 150 controls were enrolled in the case-control association study. In the second phase, heritability of susceptible alleles was investigated from 88 trio-families with CAD affected offspring. Biochemical analysis of lipids and hs-CRP was carried out spectrophotometrically, while serum TNF-alpha concentrations were determined by enzyme-linked immunosorbent assay. Genotyping of the TNF-alpha SNPs were determined by PCR-RFLP method. Elevated serum TNF-alpha and hs-CRP were observed from CAD vs. controls (P<0.0001; for both). The evaluation of TNF-alpha-308G>A polymorphism in case-control study revealed that the said SNP was significantly associated with the increased risk of CAD. The findings demonstrated a significant link between the TNF-alpha variant allele A at -308 and CAD (P=0.0035), whereas the -238 SNP was not associated with the disease. Haplotype A-G of the TNF-alpha gene at -308G>A and -238G>A showed higher frequency in the patient group compared with controls (P<0.05). Moreover, data showed preferential transmission of the disease susceptible allele A at TNF-alpha-308 from parent to affected offspring in a trio-family study (P<0.0001). The current research leads to conclusion that the TNF-alpha-308G>A polymorphism is associated with CAD in the study population. Furthermore, for the first time, we showed that the TNF-alpha-308A allele was significantly associated with the familial CAD in our high risk population. Copyright © 2014. Published by Elsevier Inc.
Matsumura, Takuma; Kinoshita, Taku; Sakurai, Yoriko; Yahaba, Misuzu; Tsushima, Kenji; Sakao, Seiichiro; Nagashima, Kengo; Ozaki, Toshinori; Kobayashi, Yoshio; Hiwasa, Takaki; Tatsumi, Koichiro
2018-01-01
Objective Although severe obstructive sleep apnea (OSA) is an important risk factor for atherosclerosis-related diseases including coronary artery disease (CAD), there is no reliable biomarker of CAD risks in patients with OSA. This study aimed to test our hypothesis that circulating autoantibodies against neuroblastoma suppressor of tumorigenicity 1 (NBL1-Abs) are associated with the prevalence of CAD in patients with OSA. Methods Eighty-two adults diagnosed with OSA by polysomnography, 96 patients with a diagnosis of acute coronary syndrome (ACS) and 64 healthy volunteers (HVs) were consecutively enrolled. Serum samples were collected from patients with OSA at diagnostic polysomnography and from patients with ACS at disease onset. Serum NBL1-Ab level was measured by amplified luminescence proximity homogeneous assay and its association with clinical variables related to atherosclerosis was evaluated. Results NBL1-Ab level was significantly elevated in patients with both OSA and ACS compared with HVs. Subgroup analyses showed that NBL1-Ab level was markedly higher in patients with severe OSA and OSA patients with a history of CAD. Weak associations were observed between NBL1-Ab level and apnea-hypopnea index, age, mean SpO2 and arousal index, whereas significantly higher NBL1-Ab levels were observed in OSA patients with a history of CAD than in those without a history of CAD. Sensitivity analysis using a logistic regression model also demonstrated that increased NBL1-Ab levels were associated with the previous history of CAD in patients with OSA. Conclusions Elevated NBL1-Ab levels may be associated with the prevalence of CAD in patients with OSA, which needs to be confirmed further. PMID:29596467
Yang, Li-Juan; Liu, Yu-Qin; Gu, Bei; Bian, Xiao-Cui; Feng, Hai-Liang; Yang, Zhen-Li; Liu, Yan-Yan
2010-12-01
To investigate the role that E-cadherin (E-cad) plays on cell adhesion and proliferation of human breast carcinoma. E-cad expression vector was transfected into an E-cad-negative human breast carcinoma MDA-MB-231 cells. G418 was used to screen positive clones. E-cad, β-catenin (β-cat) and cyclin D1 expressions of these clones were confirmed by Western blot. Their cell-cell and cell-matrix adhesion abilities were detected. E-cad/β-catenin interaction was confirmed by immunoprecipitation. Cell proliferation was evaluated by MTT. Cell apoptosis was analyzed by flow cytometry. Direct two-step immunocytochemistry was used to detect the localization of β-cat. E-cad(+) cell strains Ecad-231-7 and Ecad-231-9 were established. When cultured in ultra-low-binding dishes Ecad-231 cells grow in suspension while Ecad-231-7 and Ecad-231-9 cells grow in large clamps. When co-cultured with HCT116 cells, the average adhesion rates at 30 min are 39.0%, 60.0% and 59.5% for MDA-MB-231, Ecad-231-7 and Ecad-231-9 respectively. The average detachment rates by EDTA for 5 min are 37.4%, 4.2% and 7.4% respectively. So E-cad expression enhanced hemotypic and heterotypic cell-cell adhesion and cell-matrix adhesion. Forced exogenously expressed E-cad could combine with endogenous β-cat, whereas down stream cyclin D1 expression was significantly decreased, as evidenced by Western blot. The rates of cell apoptosis of MDA-MB-231, Ecad-231-7 and Ecad-231-9 were 1.8%, 2.0% and 2.1%. Expression of E-cad had no obvious effect on the apoptosis of tumor cells with regular culture. β-cat increased in the cytoplasma. Two monoclonal tumor cell strains (Ecad-231-7 and Ecad-231-9) stably expressing E-cad were successfully established. E-cad could enhance adhesion and inhibit proliferation of human breast carcinoma cells through a pathway involving β-cat and cyclin D1.
2010-01-01
Background Peroxisome proliferator-activated receptor γ (PPARγ) is a ligand-activated transcription factor, which regulates gene expression of the key proteins involved in lipid metabolism, vascular inflammation, and proliferation. PPARγ may contribute to attenuating atherogenesis and postangioplasty restenosis. PPARγ C161→T substitution is associated with a reduced risk of coronary artery disease (CAD). Whether or not the gene substitution alters the risk of CAD in type 2 diabetes mellitus (T2DM) patients remains unclear. Methods A total of 556 unrelated subjects from a Chinese Han population, including 89 healthy subjects, 78 CAD patients, 86 T2DM patients, and 303 CAD combined with T2DM patients, were recruited to enroll in this study. PPARγC161→T gene polymorphism was determined by polymerase chain reaction and restriction fragment length polymorphisms. Plasma levels of lipoproteins, apolipoproteins, glucose, and insulin were measured by ELISA or radioimmunoassay (RIA). The coronary artery lesions were evaluated by coronary angiography. Results The frequency of the 161T allele in CAD, T2DM, and CAD combined with T2DM patients was similar to that observed in the healthy control group. However, in CAD combined with T2DM patients, the group with angiographically documented moderate stenoses had a higher frequency of the 161T allele in comparison to the group with severe stenoses (P < 0.05). Moreover, in CAD with T2DM patients, the triglyceride levels and apoB in CC homozygote carriers were significantly higher than those in "T" allele carriers. Conclusions PPARγC161→T genotypes weren't significantly associated with the risk of CAD, but were markedly correlated with severity of disease vessels in patients with CAD and T2DM. Furthermore, PPARγC161→T substitution was associated with an altered adipose, but not glucose metabolism. These results indicate that the PPARγ C161→T polymorphism may reduce the risk of severe atherogenesis by modulation of adipose metabolism, especially triglycerides and apoB, in Chinese patients with CAD and T2DM. PMID:20334678
Vojdani, M; Torabi, K; Farjood, E; Khaledi, Aar
2013-09-01
Metal-ceramic crowns are most commonly used as the complete coverage restorations in clinical daily use. Disadvantages of conventional hand-made wax-patterns introduce some alternative ways by means of CAD/CAM technologies. This study compares the marginal and internal fit of copings cast from CAD/CAM and conventional fabricated wax-patterns. Twenty-four standardized brass dies were prepared and randomly divided into 2 groups according to the wax-patterns fabrication method (CAD/CAM technique and conventional method) (n=12). All the wax-patterns were fabricated in a standard fashion by means of contour, thickness and internal relief (M1-M12: representative of CAD/CAM group, C1-C12: representative of conventional group). CAD/CAM milling machine (Cori TEC 340i; imes-icore GmbH, Eiterfeld, Germany) was used to fabricate the CAD/CAM group wax-patterns. The copings cast from 24 wax-patterns were cemented to the corresponding dies. For all the coping-die assemblies cross-sectional technique was used to evaluate the marginal and internal fit at 15 points. The Student's t- test was used for statistical analysis (α=0.05). The overall mean (SD) for absolute marginal discrepancy (AMD) was 254.46 (25.10) um for CAD/CAM group and 88.08(10.67) um for conventional group (control). The overall mean of internal gap total (IGT) was 110.77(5.92) um for CAD/CAM group and 76.90 (10.17) um for conventional group. The Student's t-test revealed significant differences between 2 groups. Marginal and internal gaps were found to be significantly higher at all measured areas in CAD/CAM group than conventional group (p< 0.001). Within limitations of this study, conventional method of wax-pattern fabrication produced copings with significantly better marginal and internal fit than CAD/CAM (machine-milled) technique. All the factors for 2 groups were standardized except wax pattern fabrication technique, therefore, only the conventional group results in copings with clinically acceptable margins of less than 120um.
Vojdani, M; Torabi, K; Farjood, E; Khaledi, AAR
2013-01-01
Statement of Problem: Metal-ceramic crowns are most commonly used as the complete coverage restorations in clinical daily use. Disadvantages of conventional hand-made wax-patterns introduce some alternative ways by means of CAD/CAM technologies. Purpose: This study compares the marginal and internal fit of copings cast from CAD/CAM and conventional fabricated wax-patterns. Materials and Method: Twenty-four standardized brass dies were prepared and randomly divided into 2 groups according to the wax-patterns fabrication method (CAD/CAM technique and conventional method) (n=12). All the wax-patterns were fabricated in a standard fashion by means of contour, thickness and internal relief (M1-M12: representative of CAD/CAM group, C1-C12: representative of conventional group). CAD/CAM milling machine (Cori TEC 340i; imes-icore GmbH, Eiterfeld, Germany) was used to fabricate the CAD/CAM group wax-patterns. The copings cast from 24 wax-patterns were cemented to the corresponding dies. For all the coping-die assemblies cross-sectional technique was used to evaluate the marginal and internal fit at 15 points. The Student’s t- test was used for statistical analysis (α=0.05). Results: The overall mean (SD) for absolute marginal discrepancy (AMD) was 254.46 (25.10) um for CAD/CAM group and 88.08(10.67) um for conventional group (control). The overall mean of internal gap total (IGT) was 110.77(5.92) um for CAD/CAM group and 76.90 (10.17) um for conventional group. The Student’s t-test revealed significant differences between 2 groups. Marginal and internal gaps were found to be significantly higher at all measured areas in CAD/CAM group than conventional group (p< 0.001). Conclusion: Within limitations of this study, conventional method of wax-pattern fabrication produced copings with significantly better marginal and internal fit than CAD/CAM (machine-milled) technique. All the factors for 2 groups were standardized except wax pattern fabrication technique, therefore, only the conventional group results in copings with clinically acceptable margins of less than 120um. PMID:24724133
Zheng, Ying-Ying; Xie, Xiang; Ma, Yi-Tong; Fu, Zhen-Yan; Ma, Xiang; Yang, Yi-Ning; Li, Xiao-Mei; Pan, Shuo; Adi, Dilare; Chen, Bang-Dang; Liu, Fen
2017-01-31
C5aR-like receptor 2 (C5L2) has been identified as a receptor for the inflammatory factor Complement 5a (C5a) and acylation-stimulating protein (ASP). ASP binding to C5L2 leading to a net accumulation of TG stores and glucose transporter. The aim of the present study is to evaluate the association of the SNPs of C5L2 gene with coronary artery disease (CAD) in a Chinese population. We examined the role of the tagging single nucleotide polymorphisms (SNPs) of C5L2 gene for CAD using a case-control design. We determined the prevalence of C5L2 genotypes in 505 CAD patients and 469 age and sex-matched healthy control subjects of Han population. There was significant difference in genotype distributions of rs2972607 and rs8112962 between CAD patients and control subjects. The rs2972607 was found to be associated with CAD in a dominant model (AA vs. AG + GG, P<0.001). Similarly, the rs8112962 was found to be associated with CAD in a dominant model (TT vs CT + CC, P=0.016). The difference remained statistically significant after multivariate adjustment (OR =1.401, 95% confidence interval [CI]:1.026~1.914, P=0.034; OR = 1.541, 95%CI:1.093~ 2.172, P=0.014; respectively). The results of this study indicate that both rs2972607 and rs8112962 of C5L2 gene are associated with CAD in a Han population of China.
Lee, Seung-Hyun; Shin, Kihyuk; Park, Sungha; Kang, Seok-Min; Choi, Donghoon; Lee, Seung-Hyo; Lee, Sang-Hak
2015-11-01
Elastin is a major arterial structural protein, and elastin-derived peptides are related to arterial change. We previously reported on a novel assay developed using aortic elastin peptides; however, its clinical implications remain unclear. In this study, we assessed whether anti-elastin antibody titers reflect the risk of coronary artery disease (CAD) or its characteristics. We included 174 CAD patients and 171 age- and sex-matched controls. Anti-elastin antibody titers were quantified by enzyme-linked immunosorbent assay. Parameters of arterial stiffness, including the augmentation index (AI) and heart-to-femoral pulse wave velocity (hfPWV), were measured non-invasively. The clinical and angiographic characteristics of CAD patients were also evaluated. Associations between anti-elastin levels and vascular characteristics were examined by linear regression analysis. The median blood level of anti-elastin was significantly lower in the CAD group than in the controls [197 arbitrary unit (a.u.) vs. 63 a.u., p<0.001]. Levels of anti-elastin were significantly lower in men and in subjects with hypertension, diabetes mellitus, hyperlipidemia, or high hfPWV. Nevertheless, anti-elastin levels were not dependent on atherothrombotic events or the angiographic severity of CAD. In a multivariate analysis, male sex (β=-0.38, p<0.001), diabetes mellitus (β=-0.62, p<0.001), hyperlipidemia (β=-0.29, p<0.001), and AI (β=-0.006, p=0.02) were ultimately identified as determinants of anti-elastin levels. Lower levels of anti-elastin are related to CAD. The association between antibody titers and CAD is linked to arterial stiffness rather than the advancement of atherosclerosis.
Furuhashi, Tatsuhiko; Moroi, Masao; Joki, Nobuhiko; Hase, Hiroki; Masai, Hirofumi; Kunimasa, Taeko; Fukuda, Hiroshi; Sugi, Kaoru
2013-02-01
Pretest probability of coronary artery disease (CAD) facilitates diagnosis and risk stratification of CAD. Stress myocardial perfusion imaging (MPI) and chronic kidney disease (CKD) are established major predictors of cardiovascular events. However, the role of CKD to assess pretest probability of CAD has been unclear. This study evaluates the role of CKD to assess the predictive value of cardiovascular events under consideration of pretest probability in patients who underwent stress MPI. Patients with no history of CAD underwent stress MPI (n = 310; male = 166; age = 70; CKD = 111; low/intermediate/high pretest probability = 17/194/99) and were followed for 24 months. Cardiovascular events included cardiac death and nonfatal acute coronary syndrome. Cardiovascular events occurred in 15 of the 310 patients (4.8 %), but not in those with low pretest probability which included 2 CKD patients. In patients with intermediate to high pretest probability (n = 293), multivariate Cox regression analysis identified only CKD [hazard ratio (HR) = 4.88; P = 0.022) and summed stress score of stress MPI (HR = 1.50; P < 0.001) as independent and significant predictors of cardiovascular events. Cardiovascular events were not observed in patients with low pretest probability. In patients with intermediate to high pretest probability, CKD and stress MPI are independent predictors of cardiovascular events considering the pretest probability of CAD in patients with no history of CAD. In assessing pretest probability of CAD, CKD might be an important factor for assessing future cardiovascular prognosis.
Pelletier, Roxanne; Arsenault, André; Dupuis, Jocelyn; Laurin, Catherine; Blais, Lucie; Lavoie, Kim L
2015-01-01
Objectives To assess whether depression and anxiety increase the risk of mortality and major adverse cardiovascular events (MACE), among patients with and without coronary artery disease (CAD). Design and setting, and patients DECADE (Depression Effects on Coronary Artery Disease Events) is a prospective observational study of 2390 patients referred at the Montreal Heart Institute. Patients were followed for 8.8 years, between 1998 and 2009. Depression and anxiety were assessed using a psychiatric interview (Primary Care Evaluation of Mental Disorders, PRIME-MD). Outcomes data were obtained from Quebec provincial databases. Main outcome measures All-cause mortality and MACE. Results After adjustment for covariates, patients with depression were at increased risks of all-cause mortality (relative risk (RR)=2.84; 95% CI 1.25 to 6.49) compared with patients without depression. Anxiety was not associated with increased mortality risks (RR=0.86; 95% CI 0.31 to 2.36). When patients were stratified according to CAD status, depression increased the risk of mortality among patients with no CAD (RR=4.39; 95% CI 1.12 to 17.21), but not among patients with CAD (RR=2.32; 95% CI 0.78 to 6.88). Neither depression nor anxiety was associated with MACE among patients with or without CAD. Conclusions and relevance Depression, but not anxiety, was an independent risk factor for all-cause mortality in patients without CAD. The present study contributes to a better understanding of the relative and unique role of depression versus anxiety among patients with versus without CAD. PMID:26671946
Sugiyama, Toshiko; Kameyama, Atsushi; Enokuchi, Tomoka; Haruyama, Akiko; Chiba, Aoi; Sugiyama, Setsuko; Hosaka, Makoto; Takahashi, Toshiyuki
2017-06-01
This study aimed to evaluate the effect of dental prophylaxis on the surface gloss and roughness of different indirect restorative materials for computer-aided design/computer-aided manufacturing (CAD/CAM): two types of CAD/CAM composite resin blocks (Shofu Block HC and Estelite Block) and two types of CAD/CAM ceramic blocks (IPS Empress CAD and Celtra DUO). After polishing the CAD/CAM blocks and applying prophylaxis pastes, professional dental prophylaxis was performed using four different experimental protocols (n = 5 each): mechanical cleaning with Merssage Regular for 10 s four times (Group 1); four cycles of mechanical cleaning with Merssage Regular for 10 s and Merssage Fine for 10 s (Group 2); four cycles of mechanical cleaning with Merssage Regular for 10 s and Merssage Fine for 30 s (Group 3); and mechanical cleaning with Merssage Fine for 10 s four times (Group 4). A glossmeter was used to measure surface gloss before and after mechanical cleaning, and a contact stylus profilometer was used to measure surface roughness (Ra). Polishing with prophylactic paste led to a significant reduction in surface gloss and increase in surface roughness among resin composite blocks, whereas the polishing-related change in surface gloss or roughness was smaller in Celtra DUO, a zirconia-reinforced lithium silicate block. Changes in surface gloss and roughness due to polishing with a prophylactic paste containing large particles were not improved by subsequent polishing with a prophylactic paste containing fine particles. Key words: CAD/CAM, professional dental prophylaxis, prophylactic paste, surface gloss, surface roughness.
Ghaffari, Mohammad Ali; Askari Sede, Saeed; Rashtchizadeh, Nadereh; Mohammadzadeh, Ghorban; Majidi, Shahla
2014-01-01
Introduction: We evaluated the association between four polymorphisms in the CRP gene with serum C-reactive protein (CRP) levels, prevalence and severity of coronary artery disease (CAD) in type 2 diabetes mellitus (T2DM) patients. Methods: We performed coronary angiography for 308 T2DM patients and classified them into two groups: T2DM with CAD and T2DM without CAD. All patients were from Ahvaz, Iran. serum levels of CRP, glucose and lipid profile were measured. Genotyping was performed by PCR/RFLP, and the severity of coronary artery disease was determined by Gensini score. Results: The GG genotype of SNP rs279421 was associated with the increased risk of CAD (OR= 2.38; 95% CI: 1.12- 5.8; p= 0.02) and CA, TT, TA genotypes and A allele of SNP rs3091244 and GA genotypes and A allele of SNP rs3093062 were significantly associated with increased CRP levels. None of genotypes or alleles was associated with Gensini score. We found that the haplotype 7 (AGCG) was associated with decreased risk of CAD (OR= 0.11; 95% CI: 0.02, 0.66; p= 0.017) and the Gensini score was correlated with increased levels of CRP, only in CAD group. Conclusion: Although genetic polymorphisms were influenced on serum RP levels, none of the alleles and genotypes raising or falling C-reactive protein levels was consistently associated with an increased prevalence of CAD or protected from that. PMID:25337466
Sugiyama, Toshiko; Enokuchi, Tomoka; Haruyama, Akiko; Chiba, Aoi; Sugiyama, Setsuko; Hosaka, Makoto; Takahashi, Toshiyuki
2017-01-01
Background This study aimed to evaluate the effect of dental prophylaxis on the surface gloss and roughness of different indirect restorative materials for computer-aided design/computer-aided manufacturing (CAD/CAM): two types of CAD/CAM composite resin blocks (Shofu Block HC and Estelite Block) and two types of CAD/CAM ceramic blocks (IPS Empress CAD and Celtra DUO). Material and Methods After polishing the CAD/CAM blocks and applying prophylaxis pastes, professional dental prophylaxis was performed using four different experimental protocols (n = 5 each): mechanical cleaning with Merssage Regular for 10 s four times (Group 1); four cycles of mechanical cleaning with Merssage Regular for 10 s and Merssage Fine for 10 s (Group 2); four cycles of mechanical cleaning with Merssage Regular for 10 s and Merssage Fine for 30 s (Group 3); and mechanical cleaning with Merssage Fine for 10 s four times (Group 4). A glossmeter was used to measure surface gloss before and after mechanical cleaning, and a contact stylus profilometer was used to measure surface roughness (Ra). Results Polishing with prophylactic paste led to a significant reduction in surface gloss and increase in surface roughness among resin composite blocks, whereas the polishing-related change in surface gloss or roughness was smaller in Celtra DUO, a zirconia-reinforced lithium silicate block. Conclusions Changes in surface gloss and roughness due to polishing with a prophylactic paste containing large particles were not improved by subsequent polishing with a prophylactic paste containing fine particles. Key words:CAD/CAM, professional dental prophylaxis, prophylactic paste, surface gloss, surface roughness. PMID:28638554
Nejatidanesh, Farahnaz; Shakibamehr, Amir Hossein; Savabi, Omid
2016-02-01
To evaluate the accuracy of marginal and internal adaptation of 2 computer-aided design/computer-aided manufacturing (CAD/CAM) and 2 conventionally made cement retained implant-supported restorations. An abutment and its corresponding fixture analog (Astra Tech) were inserted in left central incisor area of a maxillary cast. Four types of implant-supported single restorations were fabricated on the abutment (n = 10): e.max CAD (Cerec AC system), zirconia-based (Cercon system), IPS e.max Press, and metal-ceramic restorations. The internal and marginal gaps of the studied groups were measured by replica method and stereomicroscope. Data were subjected to 1-way ANOVA and Scheffe post hoc tests (α = 0.05). Mean internal gaps of Cercon (59.48 ± 16.49 μm) and e.max Press (75.62 ± 26.92 μm) groups were significantly different from e.max CAD (120.29 ± 16.74 μm) group, but there was no significant difference between metal-ceramic restorations (89.65 ± 47.84 μm) and e.max CAD. The marginal gaps of e.max CAD (32.02 ± 10.38 μm) and Cercon restorations (34.26 ± 11.41 μm) were significantly superior from metal ceramics (59.19 ± 17.81 μm) and e.max press (74.99 ± 24.51 μm). Within the limitations of this study, it can be concluded that although the marginal and internal gaps of the studied implant-supported restorations were in the clinically acceptable range, single crowns made with CAD/CAM technology provide better marginal fit.
Yousefi, Mina; Krzyżak, Adam; Suen, Ching Y
2018-05-01
Digital breast tomosynthesis (DBT) was developed in the field of breast cancer screening as a new tomographic technique to minimize the limitations of conventional digital mammography breast screening methods. A computer-aided detection (CAD) framework for mass detection in DBT has been developed and is described in this paper. The proposed framework operates on a set of two-dimensional (2D) slices. With plane-to-plane analysis on corresponding 2D slices from each DBT, it automatically learns complex patterns of 2D slices through a deep convolutional neural network (DCNN). It then applies multiple instance learning (MIL) with a randomized trees approach to classify DBT images based on extracted information from 2D slices. This CAD framework was developed and evaluated using 5040 2D image slices derived from 87 DBT volumes. The empirical results demonstrate that this proposed CAD framework achieves much better performance than CAD systems that use hand-crafted features and deep cardinality-restricted Bolzmann machines to detect masses in DBTs. Copyright © 2018 Elsevier Ltd. All rights reserved.
Srinivasan, Murali; Gjengedal, Harald; Cattani-Lorente, Maria; Moussa, Mira; Durual, Stéphane; Schimmel, Martin; Müller, Frauke
2018-03-06
This study compared the biocompatibility, mechanical properties, and surface roughness of a pre-polymerized polymethyl methacrylate (PMMA) resin for CAD/CAM complete removable dental prostheses (CRDPs) and a traditional heat-polymerized PMMA resin. Two groups of resin substrates [Control (RC): conventional PMMA; Test (RA): CAD/CAM PMMA] were fabricated. Human primary osteoblasts and mouse embryonic-fibroblasts were cultured for biocompatibility assays. Mechanical properties and surface roughness were compared. ANOVA revealed no difference between the resin groups in the biocompatibility assays. RA demonstrated a higher elastic modulus (p=0.002), young's modulus (p=0.002), plastic energy (p=0.002), ultimate strength (p=0.0004), yield point (p=0.016), strain at yield point (p=0.037), and toughness (p<0.0001); while RC displayed a higher elastic energy (p<0.0001). Laser profilometry concluded a rougher surface profile (p<0.0001) for RA. This study concluded that the tested CAD/CAM resin was equally biocompatible and presented with improved mechanical properties than the traditional heat-polymerized PMMA resin used in the fabrication of CRDPs.
Value of coronary computed tomography as a prognostic tool.
Contractor, Tahmeed; Parekh, Maansi; Ahmed, Shameer; Martinez, Matthew W
2012-08-01
Coronary computed tomography angiography (CCTA) has become an important part of our armamentarium for noninvasive diagnosis of coronary artery disease (CAD). Emerging technologies have produced lower radiation dose, improved spatial and temporal resolution, as well as information about coronary physiology. Although the prognostic role of coronary artery calcium scoring is known, similar evidence for CCTA has only recently emerged. Initial, small studies in various patient populations have indicated that CCTA-identified CAD may have a prognostic value. These findings were confirmed in a recent analysis of the international, prospective Coronary CT Angiography Evaluation For Clinical Outcomes: An International Multicenter (CONFIRM) registry. An incremental increase in mortality was found with a worse severity of CAD on a per-patient, per-vessel, and per-segment basis. In addition, age-, sex-, and ethnicity-based differences in mortality were also found. Whether changing our management algorithms based on these findings will affect outcomes is unclear. Large prospective studies utilizing targeted management strategies for obstructive and nonobstructive CAD are required to incorporate these recent findings into our daily practice. © 2012 Wiley Periodicals, Inc.
Hasebe, Naoyuki; Moroi, Masao; Nishimura, Masato; Hara, Kazuhiro; Hase, Hiroki; Hashimoto, Akiyoshi; Kumita, Shinichiro; Haze, Kazuo; Momose, Mitsuru; Nagai, Yoji; Sugimoto, Tokuichiro; Kusano, Eiji; Akiba, Takashi; Nakata, Tomoaki; Nishimura, Tsunehiko; Tamaki, Nagara; Kikuchi, Kenjiro
2008-12-01
Cardiovascular disease is the leading cause of morbidity and mortality in patients undergoing hemodialysis. Such patients frequently develop complications such as asymptomatic coronary artery disease (CAD). Accordingly, CAD must ideally be diagnosed at an early stage to improve prognosis. Although myocardial perfusion single photon emission computed tomography (SPECT) is valuable for diagnosing CAD, the stress test is not always applicable to patients on hemodialysis. Thus, we proposed a multicenter, prospective cohort study called "B-SAFE" to investigate the applicability of resting (123)I-labeled beta-methyl-iodophenylpentadecanoic acid ((123)I-BMIPP)-SPECT will be used to diagnose cardiac disease and evaluate the prognosis of hemodialysis patients by imaging myocardial fatty acid metabolism. B-SAFE began enrolling patients from June 2006 at 48 facilities. We performed (123)I-BMIPP-SPECT on 702 hemodialysis patients with risk factors for CAD until 30 November 2007 and plan to follow up for three years. The primary endpoints will be cardiac death and sudden death. This study should end in 2010.
Davos, Constantinos H; Doherty, Patrick; Saure, Daniel; Metzendorf, Maria-Inti; Salzwedel, Annett; Völler, Heinz; Jensen, Katrin; Schmid, Jean-Paul
2016-01-01
Background The prognostic effect of multi-component cardiac rehabilitation (CR) in the modern era of statins and acute revascularisation remains controversial. Focusing on actual clinical practice, the aim was to evaluate the effect of CR on total mortality and other clinical endpoints after an acute coronary event. Design Structured review and meta-analysis. Methods Randomised controlled trials (RCTs), retrospective controlled cohort studies (rCCSs) and prospective controlled cohort studies (pCCSs) evaluating patients after acute coronary syndrome (ACS), coronary artery bypass grafting (CABG) or mixed populations with coronary artery disease (CAD) were included, provided the index event was in 1995 or later. Results Out of n = 18,534 abstracts, 25 studies were identified for final evaluation (RCT: n = 1; pCCS: n = 7; rCCS: n = 17), including n = 219,702 patients (after ACS: n = 46,338; after CABG: n = 14,583; mixed populations: n = 158,781; mean follow-up: 40 months). Heterogeneity in design, biometrical assessment of results and potential confounders was evident. CCSs evaluating ACS patients showed a significantly reduced mortality for CR participants (pCCS: hazard ratio (HR) 0.37, 95% confidence interval (CI) 0.20–0.69; rCCS: HR 0.64, 95% CI 0.49–0.84; odds ratio 0.20, 95% CI 0.08–0.48), but the single RCT fulfilling Cardiac Rehabilitation Outcome Study (CROS) inclusion criteria showed neutral results. CR participation was also associated with reduced mortality after CABG (rCCS: HR 0.62, 95% CI 0.54–0.70) and in mixed CAD populations. Conclusions CR participation after ACS and CABG is associated with reduced mortality even in the modern era of CAD treatment. However, the heterogeneity of study designs and CR programmes highlights the need for defining internationally accepted standards in CR delivery and scientific evaluation. PMID:27777324
The health farm concept in the primary prevention of coronary artery disease.
Ahmad, A M
1995-12-01
The purpose of the study is as a preliminary outline of the effectiveness of initiating high-risk individuals into the Health Farm concept in the primary prevention of coronary artery disease (CAD). Thirty-five (35) Army personnel, all male, with risk-factors for CAD were brought together on a Health Farm concept to go through a predesigned ten-day Farm programme comprising CAD risk-assessment, comprehensive medical examination, relevant blood chemistry analysis, physical fitness evaluation, individualised weekly exercise routine, physical fitness workouts, individualised diet, lectures, group discussion and individual counselling. Description of the participants (as measurements of various relevant parameters) are made at the start and as participant-achievement. The results show general participant-compliance to the programme which was reflected by significant changes in weight (p < 0.005), percentile VO2Max (p < 0.005), percentile push-ups (p < 0.005) and girth-difference (p < 0.005). The study showed that the Health Farm concept is effective in initiating high-risk individuals into lifestyles conducive to the primary prevention of CAD. Sustained results towards primary prevention of CAD can be expected with compliance to a long-term follow-up that has been identified and to which participants have been made aware of. Other previous intervention studies are briefly discussed.
Lapierre, Catherine; Pollet, Brigitte; Petit-Conil, Michel; Toval, Gabriel; Romero, Javier; Pilate, Gilles; Leplé, Jean-Charles; Boerjan, Wout; Ferret, Valérie; De Nadai, Véronique; Jouanin, Lise
1999-01-01
We evaluated lignin profiles and pulping performances of 2-year-old transgenic poplar (Populus tremula × Populus alba) lines severely altered in the expression of caffeic acid/5-hydroxyferulic acid O-methyltransferase (COMT) or cinnamyl alcohol dehydrogenase (CAD). Transgenic poplars with CAD or COMT antisense constructs showed growth similar to control trees. CAD down-regulated poplars displayed a red coloration mainly in the outer xylem. A 90% lower COMT activity did not change lignin content but dramatically increased the frequency of guaiacyl units and resistant biphenyl linkages in lignin. This alteration severely lowered the efficiency of kraft pulping. The Klason lignin level of CAD-transformed poplars was slightly lower than that of the control. Whereas CAD down-regulation did not change the frequency of labile ether bonds or guaiacyl units in lignin, it increased the proportion of syringaldehyde and diarylpropane structures and, more importantly with regard to kraft pulping, of free phenolic groups in lignin. In the most depressed line, ASCAD21, a substantially higher content in free phenolic units facilitated lignin solubilization and fragmentation during kraft pulping. These results point the way to genetic modification of lignin structure to improve wood quality for the pulp industry. PMID:9880356
Girod, Sabine; Schvartzman, Sara C; Gaudilliere, Dyani; Salisbury, Kenneth; Silva, Rebeka
2016-01-01
Computer-assisted surgical (CAS) planning tools are available for craniofacial surgery, but are usually based on computer-aided design (CAD) tools that lack the ability to detect the collision of virtual objects (i.e., fractured bone segments). We developed a CAS system featuring a sense of touch (haptic) that enables surgeons to physically interact with individual, patient-specific anatomy and immerse in a three-dimensional virtual environment. In this study, we evaluated initial user experience with our novel system compared to an existing CAD system. Ten surgery resident trainees received a brief verbal introduction to both the haptic and CAD systems. Users simulated mandibular fracture reduction in three clinical cases within a 15 min time limit for each system and completed a questionnaire to assess their subjective experience. We compared standard landmarks and linear and angular measurements between the simulated results and the actual surgical outcome and found that haptic simulation results were not significantly different from actual postoperative outcomes. In contrast, CAD results significantly differed from both the haptic simulation and actual postoperative results. In addition to enabling a more accurate fracture repair, the haptic system provided a better user experience than the CAD system in terms of intuitiveness and self-reported quality of repair.
Zhu, Lin-Lin; Qiu, Li-Hong; Liu, Li-Yang; Li, Xiao-Lin
2017-10-01
To determine the effect of the thickness of reinforced glass ceramics on the degree of conversion (DC) of three dual-cure resin cements (Multilink N, RelyX Ultimate and NX3-Nexus). Upcera reinforced glass ceramics and IPS e.max CAD test specimen were processed, with different thickness, transmittance was tested by ultraviolet and visible spectrometer. The DC was evaluated using Fourier transform infrared (FT-IR) spectrometer, then the degree of conversion of polymerization before and after curing was calculated. SPSS 21.0 software package was used for data analysis. Transmittance decreased along with the thickness of reinforced glass ceramics increased. At 2 mm -thickness transmittance of upcera lithium disilicate glass ceramics was superior to IPS e.max CAD. The DC of dual-cured resin cement was decreased with the increase of thickness. At the same 2 mm group, the DC of Multilink N and RelyX Ultimate under upcera lithium disilicate glass ceramics were superior to that under IPS e.max CAD groups. At 2 mm-thickness transmittance of upcera lithium disilicate glass ceramics was superior to IPS e.max CAD. At the same 2 mm group, the DC of Multilink N and RelyX Ultimate under upcera lithium disilicate glass ceramics were superior to that under IPS e.max CAD groups.
de Souza, Priscilla Azambuja Lopes; Marcadenti, Aline; Portal, Vera Lúcia
2017-01-01
Coronary artery disease (CAD) is responsible for more than 7 million deaths worldwide. In the early stages of the development of atherosclerotic plaques, cardiovascular risk factors stimulate vascular endothelial cells, initiating an inflammatory process, fundamental in the pathogenesis of CAD. The inclusion of potentially cardioprotective foods, such as olive oil, to the diet, may aid in the control of these risk factors, and in the reduction of cytokines and inflammatory markers. The present review aims to address the interaction between phenolic compounds present in olive oil, and inflammation, in the prevention and treatment of CAD. In vitro and in vivo studies suggest that phenolic compounds, such as hydroxytyrosol, tyrosol, and their secoiridoid derivatives, may reduce the expression of adhesion molecules and consequent migration of immune cells, modify the signaling cascade and the transcription network (blocking the signal and expression of the nuclear factor kappa B), inhibit the action of enzymes responsible for the production of eicosanoids, and consequently, decrease circulating levels of inflammatory markers. Daily consumption of olive oil seems to modulate cytokines and inflammatory markers related to CAD in individuals at risk for cardiovascular diseases. However, clinical studies that have evaluated the effects of olive oil and its phenolic compounds on individuals with CAD are still scarce. PMID:28973999
Guo, Qi; Lu, Xiaoni; Gao, Ya; Zhang, Jingjing; Yan, Bin; Su, Dan; Song, Anqi; Zhao, Xi; Wang, Gang
2017-03-07
Grading of essential hypertension according to blood pressure (BP) level may not adequately reflect clinical heterogeneity of hypertensive patients. This study was carried out to explore clinical phenotypes in essential hypertensive patients using cluster analysis. This study recruited 513 hypertensive patients and evaluated BP variations with ambulatory blood pressure monitoring. Four distinct hypertension groups were identified using cluster analysis: (1) younger male smokers with relatively high BP had the most severe carotid plaque thickness but no coronary artery disease (CAD); (2) older women with relatively low diastolic BP had more diabetes; (3) non-smokers with a low systolic BP level had neither diabetes nor CAD; (4) hypertensive patients with BP reverse dipping were most likely to have CAD but had least severe carotid plaque thickness. In binary logistic analysis, reverse dipping was significantly associated with prevalence of CAD. Cluster analysis was shown to be a feasible approach for investigating the heterogeneity of essential hypertension in clinical studies. BP reverse dipping might be valuable for prediction of CAD in hypertensive patients when compared with carotid plaque thickness. However, large-scale prospective trials with more information of plaque morphology are necessary to further compare the predicative power between BP dipping pattern and carotid plaque.
Guo, Qi; Lu, Xiaoni; Gao, Ya; Zhang, Jingjing; Yan, Bin; Su, Dan; Song, Anqi; Zhao, Xi; Wang, Gang
2017-01-01
Grading of essential hypertension according to blood pressure (BP) level may not adequately reflect clinical heterogeneity of hypertensive patients. This study was carried out to explore clinical phenotypes in essential hypertensive patients using cluster analysis. This study recruited 513 hypertensive patients and evaluated BP variations with ambulatory blood pressure monitoring. Four distinct hypertension groups were identified using cluster analysis: (1) younger male smokers with relatively high BP had the most severe carotid plaque thickness but no coronary artery disease (CAD); (2) older women with relatively low diastolic BP had more diabetes; (3) non-smokers with a low systolic BP level had neither diabetes nor CAD; (4) hypertensive patients with BP reverse dipping were most likely to have CAD but had least severe carotid plaque thickness. In binary logistic analysis, reverse dipping was significantly associated with prevalence of CAD. Cluster analysis was shown to be a feasible approach for investigating the heterogeneity of essential hypertension in clinical studies. BP reverse dipping might be valuable for prediction of CAD in hypertensive patients when compared with carotid plaque thickness. However, large-scale prospective trials with more information of plaque morphology are necessary to further compare the predicative power between BP dipping pattern and carotid plaque. PMID:28266630
Association between vaspin level and coronary artery disease in patients with type 2 diabetes.
Hao, Fei; Zhang, Hiujuan; Zhu, Jinying; Kuang, Hongyu; Yu, Qiuxia; Bai, Mengmeng; Mu, Jiawei
2016-03-01
Adipokines contribute to the atherosclerotic process, connecting obesity and diabetes to cardiovascular disease. Vaspin is a recently discovered adipokine, so data about the relationship of vaspin to coronary artery disease in type-2 diabetes mellitus (T2DM) is limited. The current study was designed to evaluate the association of vaspin with the presence of coronary artery disease in T2DM. We enrolled 228 patients with T2DM, with or without CAD, between March 2010 and July 2011, and 120 healthy control participants. Serum vaspin, homeostasis model assessment of insulin resistance (HOMA-IR) and other cardiovascular risk factors were assayed. Vaspin levels were significantly increased in patients with T2DM compared to healthy individuals, and were further increased in patients with both T2DM and CAD compared to those with T2DM but without CAD. Moreover, vaspin correlated positively with body mass index, fasting plasma glucose, insulin and HOMA-IR in all patients with T2DM (P<0.05). Furthermore, in multivariate logistic regression analysis, vaspin level was associated with the presence of CAD in patients with T2DM. Vaspin correlates with CAD in T2DM. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
de França, Danilo Gonzaga; Morais, Maria Helena; das Neves, Flávio D; Carreiro, Adriana Fonte; Barbosa, Gustavo As
The aim of this study was to evaluate the effectiveness of fabrication methods (computer-aided design/computer-aided manufacture [CAD/CAM], copy-milling, and conventional casting) in the fit accuracy of three-unit, screw-retained fixed dental prostheses. Sixteen three-unit implant-supported screw-retained frameworks were fabricated to fit an in vitro model. Eight frameworks were fabricated using the CAD/CAM system, four in zirconia and four in cobalt-chromium. Four zirconia frameworks were fabricated using the copy-milled system, and four were cast in cobalt-chromium using conventional casting with premachined abutments. The vertical and horizontal misfit at the implant-framework interface was measured using scanning electron microscopy at ×250. The results for vertical misfit were analyzed using Kruskal-Wallis and Mann-Whitney tests. The horizontal misfits were categorized as underextended, equally extended, or overextended. Statistical analysis established differences between groups according to the chi-square test (α = .05). The mean vertical misfit was 5.9 ± 3.6 μm for CAD/CAM-fabricated zirconia, 1.2 ± 2.2 μm for CAD/CAM-fabricated cobalt-chromium frameworks, 7.6 ± 9.2 μm for copy-milling-fabricated zirconia frameworks, and 11.8 (9.8) μm for conventionally fabricated frameworks. The Mann-Whitney test revealed significant differences between all but the zirconia-fabricated frameworks. A significant association was observed between the horizontal misfits and the fabrication method. The percentage of horizontal misfits that were underextended and overextended was higher in milled zirconia (83.3%), CAD/CAM cobaltchromium (66.7%), cast cobalt-chromium (58.3%), and CAD/CAM zirconia (33.3%) frameworks. CAD/CAM-fabricated frameworks exhibit better vertical misfit and low variability compared with copy-milled and conventionally fabricated frameworks. The percentage of interfaces equally extended was higher when CAD/CAM and zirconia were used.
Long-Term Prognostic Value of Coronary CT Angiography in Asymptomatic Type 2 Diabetes Mellitus.
Kang, Se Hun; Park, Gyung-Min; Lee, Seung-Whan; Yun, Sung-Cheol; Kim, Young-Hak; Cho, Young-Rak; Park, Hyun Woo; Suh, Jon; Yang, Dong Hyun; Kang, Joon-Won; Lim, Tae-Hwan; Jung, Chang Hee; Koh, Eun Hee; Lee, Woo Je; Kim, Min-Seon; Lee, Ki-Up; Park, Joong-Yeol
2016-11-01
This study sought to evaluate the long-term prognostic value of coronary computed tomography angiography (CTA) in asymptomatic patients with type 2 diabetes mellitus. There are limited data on the long-term prognostic impact of coronary CTA in asymptomatic patients with type 2 diabetes mellitus. This study analyzed clinical outcomes of 591 consecutive asymptomatic patients with type 2 diabetes mellitus who underwent coronary CTA (mean age 62.2 ± 8.3 years and 352 men [59.6%]). A cardiac event was defined as a composite of cardiac death, nonfatal myocardial infarction, unstable angina requiring hospitalization, or late coronary revascularization. Patients were categorized into 3 groups according to severity of coronary artery disease (CAD) on coronary CTA: normal coronary arteries, nonobstructive CAD (<50%), and obstructive CAD (≥50%). One hundred sixty-eight patients (28.4%) had normal coronary arteries, whereas 236 (39.9%) patients had nonobstructive CAD and 187 (31.6%) had obstructive CAD. During the follow-up period (median 5.3 years [interquartile range: 4.7 to 5.8 years]), 37 cardiac events occurred in 29 patents: 10 cardiac deaths, 2 nonfatal myocardial infarctions, 8 cases of unstable angina, and 17 late coronary revascularizations. The 6-year event-free survival rates were 99.3 ± 0.7% in patients with normal coronary arteries, 96.7 ± 1.2% in patients with nonobstructive CAD, and 86.2 ± 3.0% in patients with obstructive CAD (log-rank p < 0.001). Asymptomatic patients with type 2 diabetes mellitus with normal coronary arteries or nonobstructive CAD on coronary CTA show excellent clinical outcomes over a follow-up period of more than 5 years, whereas prognosis is worse in patients with obstructive CAD. These findings suggest long-term prognostic value of coronary CTA for asymptomatic type 2 diabetes mellitus. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Chandraratna, P Anthony N; Mohar, Dilbahar S; Sidarous, Peter F; Brar, Prabhjyot; Miller, Jeffrey; Shah, Nissar; Kadis, John; Ali, Ashgar; Mohar, Prabhsimran
2012-09-01
This investigation was designed to test the hypothesis that continuous cardiac imaging using an ultrasound transducer developed in our laboratory (ContiScan) is superior to electrocardiogram (ECG) monitoring in the diagnosis of coronary artery disease (CAD) in patients with acute non-ST segment elevation chest pain syndromes. Seventy patients with intermediate to high probability of CAD who presented with typical anginal chest pain and no evidence of ST segment elevation on the ECG were studied. The 2.5-MHz transducer is spherical in its distal part mounted in an external housing to permit steering in 360 degrees. The transducer was placed at the left sternal border to image the left ventricular short-axis view and recorded on video tape at baseline, during and after episodes of chest pain. Two ECG leads were continuously monitored. The presence of CAD was confirmed by coronary arteriography or nuclear or echocardiographic stress testing. Twenty-four patients had regional wall motion abnormalities (RWMA) on their initial echo which were unchanged during the period of monitoring. All had evidence of CAD. Twenty-eight patients had transient RWMA. All had evidence of CAD. Eighteen patients had normal wall motion throughout the monitoring period, 14 of these had no evidence of CAD, and four had evidence of CAD. These four patients did not have chest pain during monitoring. The sensitivity, specificity, and accuracy of echocardiographic monitoring for diagnosing non-ST elevation myocardial infarction was 88%, 100%, and 91% respectively. The sensitivity, specificity, and accuracy of the ECG for diagnosis of CAD were 31%, 100%, and 52%, respectively. Echocardiography was superior to ECG (P < 0.001). The data indicate that continuous cardiac imaging is superior to ECG monitoring for the diagnosis of CAD in patients presenting with acute non-ST segment elevation chest pain syndromes. This technique could be a useful adjunct to ECG monitoring for myocardial ischemia in the acute care setting. © 2012, Wiley Periodicals, Inc.
Zhang, Huifeng; Dong, Pingshuan; Yang, Xuming; Liu, Zhenghao
2014-01-01
The aim of the current study was to evaluate the association of PAI-1 4G/5G polymorphism with coronary artery disease (CAD) risk using a meta-analysis. All eligible studies were identified through a search of PubMed, EMBASE, China National Knowledge Infrastructure (CNKI), Database of Chinese Scientific and Technical Periodicals, and China Biology Medical literature database (CBM) before June 2014. The association between the PAI-1 4G/5G polymorphism and CAD risk was estimated by odds ratio (OR) and 95% confidence interval (CI). A total of 72 studies including 23557 cases and 21526 controls were eventually collected. The PAI-1 4G/5G polymorphism was significant associated with CAD risk in overall population (OR=1.19, 95% CI 1.10-1.28, P < 0.00001). The combination of adjusted ORs for CAD was 1.20 (95% CI 1.03-1.40, P=0.02). This polymorphism was associated with CAD risk in Caucasians (OR=1.10, 95% CI 1.02-1.19, P=0.01) and Asians (OR=1.46, 95% CI 1.21-1.75, P < 0.0001). This polymorphism significantly increased MI risk (OR=1.15, 95% CI 1.06-1.25, P=0.001). In the subgroup analysis by age, this polymorphism was significantly associated with early-onset CAD risk (OR=1.21, 95% CI 1.02-1.43, P=0.03). In the gender subgroup analyses, a statistically significant association was found in male CAD patients (OR=1.10, 95% CI 1.01-1.20, P=0.04). Both T2DM patients and non-T2DM patients carrying 4G allele showed increased CAD risks (OR=2.23, 95% CI 1.27-3.92, P=0.005 and OR=1.64, 95% CI 1.19-2.25, P=0.002, respectively). This meta-analysis suggested that PAI-1 4G/5G polymorphism was a risk factor for CAD.
2012-01-01
Background Exercise electrocardiography (ECG) is frequently used in the work-up of patients with suspected coronary artery disease (CAD), however the accuracy is reduced in women. Cardiovascular magnetic resonance (CMR) stress testing can accurately diagnose CAD in women. To date, a direct comparison of CMR to ECG has not been performed. Methods and results We prospectively enrolled 88 consecutive women with chest pain or other symptoms suggestive of CAD. Patients underwent a comprehensive clinical evaluation, exercise ECG, a CMR stress test including perfusion and infarct imaging, and x-ray coronary angiography (CA) within 24 hours. CAD was defined as stenosis ≥70% on quantitative analysis of CA. Exercise ECG, CMR and CA was completed in 68 females (age 66.4 ± 8.8 years, number of CAD risk factors 3.5 ± 1.4). The prevalence of CAD on CA was 29%. The Duke treadmill score (DTS) in the entire group was −3.0 ± 5.4 and was similar in those with and without CAD (−4.5 ± 5.8 and −2.4 ± 5.1; P = 0.12). Sensitivity, specificity and accuracy for CAD diagnosis was higher for CMR compared with exercise ECG (sensitivities 85% and 50%, P = 0.02, specificities 94% and 73%, P = 0.01, and accuracies 91% and 66%, P = 0.0007, respectively). Even after applying the DTS the accuracy of CMR was higher compared to exercise ECG (area under ROC curve 0.94 ± 0.03 vs 0.56 ± 0.07; P = 0.0001). Conclusions In women with intermediate-to-high risk for CAD who are able to exercise and have interpretable resting ECG, CMR stress perfusion imaging has higher accuracy for the detection of relevant obstruction of the epicardial coronaries when directly compared to exercise ECG. PMID:22697372
Dental students' self-assessment of operative preparations using CAD/CAM: a preliminary analysis.
Mays, Keith A; Levine, Eric
2014-12-01
The Commission on Dental Accreditation (CODA)'s accreditation standards for dental schools state that "graduates must demonstrate the ability to self-assess." Therefore, dental schools have developed preclinical and clinical self-assessment (SA) protocols aimed at fostering a reflective process. This study comparing students' visual SA with students' digital SA and with faculty assessment was designed to test the hypothesis that higher agreement would occur when utilizing a digital evaluation. Twenty-five first-year dental students at one dental school participated by preparing a mesial occlusal preparation on tooth #30 and performing both types of SAs. A faculty evaluation was then performed both visually and digitally using the same evaluation criteria. The Kappa statistic was used to measure agreement between evaluators. The results showed statistically significant moderate agreement between the faculty visual and faculty digital modes of evaluation for occlusal shape (K=0.507, p=0.002), proximal shape (K=0.564, p=0.001), orientation (K=0.425, p=0.001), and definition (K=0.480, p=0.001). There was slight to poor agreement between the student visual and faculty visual assessment, except for preparation orientation occlusal shape (K=0.164, p=0.022), proximal shape (K=-0.227, p=0.032), orientation (K=0.253, p=0.041), and definition (K=-0.027, p=0.824). This study showed that the students had challenges in self-assessing even when using CAD/CAM and the digital assessment did not improve the amount of student/faculty agreement.
NASA Astrophysics Data System (ADS)
de Oliveira, Helder C. R.; Mencattini, Arianna; Casti, Paola; Martinelli, Eugenio; di Natale, Corrado; Catani, Juliana H.; de Barros, Nestor; Melo, Carlos F. E.; Gonzaga, Adilson; Vieira, Marcelo A. C.
2018-02-01
This paper proposes a method to reduce the number of false-positives (FP) in a computer-aided detection (CAD) scheme for automated detection of architectural distortion (AD) in digital mammography. AD is a subtle contraction of breast parenchyma that may represent an early sign of breast cancer. Due to its subtlety and variability, AD is more difficult to detect compared to microcalcifications and masses, and is commonly found in retrospective evaluations of false-negative mammograms. Several computer-based systems have been proposed for automated detection of AD in breast images. The usual approach is automatically detect possible sites of AD in a mammographic image (segmentation step) and then use a classifier to eliminate the false-positives and identify the suspicious regions (classification step). This paper focus on the optimization of the segmentation step to reduce the number of FPs that is used as input to the classifier. The proposal is to use statistical measurements to score the segmented regions and then apply a threshold to select a small quantity of regions that should be submitted to the classification step, improving the detection performance of a CAD scheme. We evaluated 12 image features to score and select suspicious regions of 74 clinical Full-Field Digital Mammography (FFDM). All images in this dataset contained at least one region with AD previously marked by an expert radiologist. The results showed that the proposed method can reduce the false positives of the segmentation step of the CAD scheme from 43.4 false positives (FP) per image to 34.5 FP per image, without increasing the number of false negatives.
Computer-aided classification of breast masses using contrast-enhanced digital mammograms
NASA Astrophysics Data System (ADS)
Danala, Gopichandh; Aghaei, Faranak; Heidari, Morteza; Wu, Teresa; Patel, Bhavika; Zheng, Bin
2018-02-01
By taking advantages of both mammography and breast MRI, contrast-enhanced digital mammography (CEDM) has emerged as a new promising imaging modality to improve efficacy of breast cancer screening and diagnosis. The primary objective of study is to develop and evaluate a new computer-aided detection and diagnosis (CAD) scheme of CEDM images to classify between malignant and benign breast masses. A CEDM dataset consisting of 111 patients (33 benign and 78 malignant) was retrospectively assembled. Each case includes two types of images namely, low-energy (LE) and dual-energy subtracted (DES) images. First, CAD scheme applied a hybrid segmentation method to automatically segment masses depicting on LE and DES images separately. Optimal segmentation results from DES images were also mapped to LE images and vice versa. Next, a set of 109 quantitative image features related to mass shape and density heterogeneity was initially computed. Last, four multilayer perceptron-based machine learning classifiers integrated with correlationbased feature subset evaluator and leave-one-case-out cross-validation method was built to classify mass regions depicting on LE and DES images, respectively. Initially, when CAD scheme was applied to original segmentation of DES and LE images, the areas under ROC curves were 0.7585+/-0.0526 and 0.7534+/-0.0470, respectively. After optimal segmentation mapping from DES to LE images, AUC value of CAD scheme significantly increased to 0.8477+/-0.0376 (p<0.01). Since DES images eliminate overlapping effect of dense breast tissue on lesions, segmentation accuracy was significantly improved as compared to regular mammograms, the study demonstrated that computer-aided classification of breast masses using CEDM images yielded higher performance.
Yin, Xinxin; Wang, Jiali; Zheng, Wen; Ma, Jingjing; Hao, Panpan; Chen, Yuguo
2016-07-01
Both coronary computed tomography angiography (CCTA) and exercise electrocardiography (ExECG) are non-invasive testing methods for the evaluation of coronary artery disease (CAD). However, there was controversy on the diagnostic performance of these methods due to the limited data in each single study. Therefore, we performed a meta-analysis to address these issues. We searched PubMed and Embase databases up to May 22, 2015. Two authors identified eligible studies, extracted data and accessed quality. Pooled estimation of sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), summary receiver-operating characteristic curve (SROC) and the area under curve (AUC) of CCTA and ExECG for the diagnosis of CAD were calculated using Stata, Meta-Disc and Review Manager statistical software. Seven articles were included. Pooled sensitivity of CCTA and ExECG were 0.98 [95% confidence intervals (CIs): 0.95-0.99] and 0.66 (95% CIs: 0.59-0.72); pooled specificity of CCTA and ExECG were 0.84 (95% CIs: 0.81-0.87) and 0.75 (95% CIs: 0.71-0.79); pooled DOR of CCTA and ExECG were 110.24 (95% CIs: 35.07-346.55) and 6.28 (95% CIs: 2.06-19.13); and AUC of CCTA and ExECG were 0.9950±0.0046 and 0.7727±0.0638, respectively. There is no heterogeneity caused by threshold effect in CCTA or ExECG analysis. The Deeks' test showed no potential publication bias (P=0.17). CCTA has better diagnostic performance than ExECG in the evaluation of CAD, which can provide a better solution for the clinical problem of the diagnosis for CAD.
Bunevicius, Adomas; Stankus, Albinas; Brozaitiene, Julija; Girdler, Susan S; Bunevicius, Robertas
2011-08-01
The relationship between subjective fatigue, exercise capacity, and symptoms of depression and anxiety in patients with coronary artery disease (CAD) needs to be specified. In this cross-sectional study, a total of 1,470 (64% men; mean age 57 ± 11 years) consecutive CAD patients admitted for cardiac rehabilitation after treatment of acute cardiac events were evaluated for demographic characteristics, for past and current diagnosis and treatment, for New York Heart Association (NYHA) class, for symptoms of depression and for symptoms of anxiety using the Hospital Anxiety and Depression Scale, and for subjective fatigue using the Multidimensional Fatigue Inventory. On the next day, all patients underwent exercise capacity evaluation using a standard bicycle ergometer testing procedure. In univariate regression analyses, there was the strongest positive association between scores on all Multidimensional Fatigue Inventory subscales and scores on the Hospital Anxiety and Depression Scale depression and anxiety subscales and between exercise capacity and NYHA class. Multivariate regression analyses revealed that symptoms of depression were the strongest positive determinants of all dimensions of subjective fatigue and, together with other significant variables, accounted for 17% to 29% of the variance. However, neither depressive nor anxious symptoms were significant determinants of exercise capacity. The association between subjective fatigue and exercise capacity and vice versa was minimal. Subjective fatigue in CAD patients is strongly related to symptoms of depression and symptoms of anxiety. In contrast, exercise capacity in CAD patients is strongly related to NYHA functional class, with no relationship to symptoms of depression and anxiety. Copyright © 2011 Mosby, Inc. All rights reserved.
A completely automated CAD system for mass detection in a large mammographic database.
Bellotti, R; De Carlo, F; Tangaro, S; Gargano, G; Maggipinto, G; Castellano, M; Massafra, R; Cascio, D; Fauci, F; Magro, R; Raso, G; Lauria, A; Forni, G; Bagnasco, S; Cerello, P; Zanon, E; Cheran, S C; Lopez Torres, E; Bottigli, U; Masala, G L; Oliva, P; Retico, A; Fantacci, M E; Cataldo, R; De Mitri, I; De Nunzio, G
2006-08-01
Mass localization plays a crucial role in computer-aided detection (CAD) systems for the classification of suspicious regions in mammograms. In this article we present a completely automated classification system for the detection of masses in digitized mammographic images. The tool system we discuss consists in three processing levels: (a) Image segmentation for the localization of regions of interest (ROIs). This step relies on an iterative dynamical threshold algorithm able to select iso-intensity closed contours around gray level maxima of the mammogram. (b) ROI characterization by means of textural features computed from the gray tone spatial dependence matrix (GTSDM), containing second-order spatial statistics information on the pixel gray level intensity. As the images under study were recorded in different centers and with different machine settings, eight GTSDM features were selected so as to be invariant under monotonic transformation. In this way, the images do not need to be normalized, as the adopted features depend on the texture only, rather than on the gray tone levels, too. (c) ROI classification by means of a neural network, with supervision provided by the radiologist's diagnosis. The CAD system was evaluated on a large database of 3369 mammographic images [2307 negative, 1062 pathological (or positive), containing at least one confirmed mass, as diagnosed by an expert radiologist]. To assess the performance of the system, receiver operating characteristic (ROC) and free-response ROC analysis were employed. The area under the ROC curve was found to be Az = 0.783 +/- 0.008 for the ROI-based classification. When evaluating the accuracy of the CAD against the radiologist-drawn boundaries, 4.23 false positives per image are found at 80% of mass sensitivity.
Hayashino, Yasuaki; Shimbo, Takuro; Tsujii, Satoru; Ishii, Hitoshi; Kondo, Hirokazu; Nakamura, Tsukasa; Nagata-Kobayashi, Shizuko; Fukui, Tsuguya
2007-05-16
Screening for coronary artery disease (CAD) in asymptomatic diabetic patients with atherogenic risk factors is recommended by the American College of Cardiology/American Diabetes Association. It is not clear whether these guidelines apply to the Japanese population with a different epidemiology of CAD. This study evaluates the applicability of the U.S. guidelines to Japan, taking account of cost-effectiveness. A cost-effectiveness analysis using a Markov model was performed to measure the clinical benefit and cost of CAD screening in asymptomatic patients with diabetes and additional atherogenic risk factors. We evaluated cohorts of patients stratified by age, gender, and atherogenic risks. The incremental cost-effectiveness of not screening, exercise electrocardiography, exercise echocardiography, and exercise single-photon emission-tomography (SPECT) was calculated. The data used were obtained from the literature. Outcomes are expressed as US dollars per quality-adjusted life year (QALY). Compared with not screening, the incremental cost-effectiveness ratio (ICER) of exercise electrocardiography was $31,400/QALY for 60-year-old asymptomatic diabetic men, and 46,600 for 65-year-old women with hypertension and smoking. The ICER of exercise echocardiography was $31,500/QALY and of SPECT was $326,000/QALY, compared with the next dominant strategy. Sensitivity analyses found that these results varied according to age, gender, the combination of additional atherogenic risk factors, and the frequency of screening. From a societal perspective the U.S. guidelines on screening for CAD in high risk diabetic patients are applicable to the Japanese population. However, the population subjected to screening should be carefully selected to obtain greatest benefit from screening.
Wang, Jian-Guang; Fang, Wei; Yang, Min-Fu; Tian, Yue-Qin; Zhang, Xiao-Li; Shen, Rui; Sun, Xiao-Xin; Guo, Feng; Wang, Dao-Yu; He, Zuo-Xiang
2015-01-01
Abstract The effects of left bundle branch block (LBBB) on left ventricular myocardial metabolism have not been well investigated. This study evaluated these effects in patients with coronary artery disease (CAD). Sixty-five CAD patients with complete LBBB (mean age, 61.8 ± 9.7 years) and 65 without LBBB (mean age, 59.9 ± 8.4 years) underwent single photon emission computed tomography, positron emission tomography, and contrast coronary angiography. The relationship between myocardial perfusion and metabolism and reverse mismatch score, and that between QRS length and reverse mismatch score and wall motion score were evaluated. The incidence of left ventricular septum and anterior wall reverse mismatching between the two groups was significantly different (P < 0.001 and P = 0.002, respectively). The incidences of normal myocardial perfusion and metabolism in the left ventricular lateral and inferior walls were also significantly different between the two groups (P < 0.001 and P < 0.001, respectively). The incidence of septal reverse mismatching in patients with mild to moderate perfusion was significantly higher among those with LBBB than among those without LBBB (P < 0.001). In CAD patients with LBBB, septal reverse mismatching was significantly more common among those with mild to moderate perfusion than among those with severe perfusion defects (P = 0.002). The correlation between the septal reverse mismatch score and QRS length was significant (P = 0.026). In patients with CAD and LBBB, septal and anterior reverse mismatching of myocardial perfusion and metabolism was frequently present; the septal reverse mismatch score negatively correlated with the QRS interval. PMID:25997045
Barbieri, Andrea; Mantovani, Francesca; Bursi, Francesca; Bartolacelli, Ylenia; Manicardi, Marcella; Lauria, Maria Giulia; Boriani, Giuseppe
2018-01-01
Data on stress echocardiography (SE) time-related changes in referral patterns and diagnostic yield for detection of inducible ischemia could enhance Echo Lab quality benchmarks and performance measures. This study aims to evaluate temporal trends in SE test results among ambulatory patients with suspected or known coronary artery disease (CAD) in a tertiary care referral center with moderate (>100/year) volume SE activities and Cath-Lab facility. From January 2004 to December 2015, 1954 patients (mean age 62 ± 12 years, 42% women, 27% with known CAD) underwent SE (1673 exercise SE, 86%, 246 pharmacological SE, 12%, 35 pacing SE, 2%). Time was grouped into three 4 year periods, where clinical data and test results were evaluated. Our series comprised low-to-intermediate pretest probability of CAD throughout the observation period (overall pretest probability of CAD 19% ± 15%). A progressive decline over time in the rate of pharmacological SE instead of a dramatic increment of exercise SE (79%-96%, P < 0.0001) was noted. The use of beta-blockers increased (from 43% to 66%, P < 0.0001), while the use of nitrates decreased (from 11% to 4%, P < 0.0001) over time. We noted a very uncommon occurrence of abnormal test results with a further decrease in the last period (from 11% to 3%, P < 0.0001). We observed, over a 12-year period, a progressive decrease in the frequency of inducible myocardial ischemia among patients with known or suspected CADe referred to our Echo Lab for SE with Cath-Lab facility, and this trend was parallel to changes in SE referral practice. These findings are particularly relevant if we consider the practical implications on diagnostic SE accuracy and risk assessment.
Wimmer, Timea; Huffmann, Anne Mildred Sophie; Eichberger, Marlis; Schmidlin, Patrick R; Stawarczyk, Bogna
2016-06-01
To test and compare the two-body wear rate of three CAD/CAM polymer materials and the influence of specimen geometry, antagonist material and test set-up configuration. Three CAD/CAM polymeric materials were assessed: a thermoplastic polyetheretherketone (PEEK), an experimental nanohybrid composite (COMP) and a PMMA-based material (PMMA). Crown-shaped and flat specimens were prepared from each material. The specimens underwent thermo-mechanical loading (50N, 5/55°C; 600,000 chewing cycles) opposed to human enamel and stainless steel antagonists. Half of the specimens of each group were loaded with a sliding movement of 0.7mm, the remaining half without. Thereby, 24 different test set-ups were investigated (n=12). Wear of the materials and antagonists was evaluated with a match-3D procedure. The topography of all surfaces was examined with scanning electron microscopy (SEM). Data were statistically evaluated with four-/one-way ANOVA followed by Scheffé post hoc test and unpaired t-test (p<0.05). All PEEK specimens showed significantly less material loss than COMP and PMMA specimens when loaded laterally. Within the axial loaded groups this was only true for the flat specimens tested with enamel antagonists. Crown specimens of these groups exhibited lower loss values than flat ones. Lateral force application led mostly to significantly higher material loss than the axial load application. On the antagonist side, no impact of CAD/CAM polymer material, antagonist material, force application and specimen geometry was found. Wear of PEEK was lower than that of the resin-based materials when lateral forces were applied, but showed comparable antagonist wear rates at the same time. Copyright © 2016 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Zizzari, Vincenzo; Borelli, Bruna; De Colli, Marianna; Tumedei, Margherita; Di Iorio, Donato; Zara, Susi; Sorrentino, Roberto; Cataldi, Amelia; Gherlone, Enrico Felice; Zarone, Fernando; Tetè, Stefano
2013-01-01
Summary Aim To evaluate the growth of Human Gingival Fibroblasts (HGFs) cultured onto sample discs of CAD/CAM zirconia and veneering ceramic for zirconia by means of Scanning Electron Microscope (SEM) analysis at different experimental times. Methods A total of 26 experimental discs, divided into 2 groups, were used: Group A) CAD/CAM zirconia (3Y-TZP) discs (n=13); Group B) veneering ceramic for zirconia discs (n=13). HGFs were obtained from human gingival biopsies, isolated and placed in culture plates. Subsequently, cells were seeded on experimental discs at 7,5×103/cm2 concentration and cultured for a total of 7 days. Discs were processed for SEM observation at 3h, 24h, 72h and 7 days. Results In Group A, after 3h, HGFs were adherent to the surface and showed a flattened profile. The disc surface covered by HGFs resulted to be wider in Group A than in Group B samples. At SEM observation, after 24h and 72h, differences in cell attachment were slightly noticeable between the groups, with an evident flattening of HGFs on both surfaces. All differences between Group A and group B became less significant after 7 days of culture in vitro. Conclusions SEM analysis of HGFs showed differences in terms of cell adhesion and proliferation, especially in the early hours of culture. Results showed a better adhesion and cell growth in Group A than in Group B, especially up to 72h in vitro. Differences decreased after 7 days, probably because of the rougher surface of CAD/CAM zirconia, promoting better cell adhesion, compared to the smoother surface of veneering ceramic. PMID:24611089
Selection of examples in case-based computer-aided decision systems
Mazurowski, Maciej A.; Zurada, Jacek M.; Tourassi, Georgia D.
2013-01-01
Case-based computer-aided decision (CB-CAD) systems rely on a database of previously stored, known examples when classifying new, incoming queries. Such systems can be particularly useful since they do not need retraining every time a new example is deposited in the case base. The adaptive nature of case-based systems is well suited to the current trend of continuously expanding digital databases in the medical domain. To maintain efficiency, however, such systems need sophisticated strategies to effectively manage the available evidence database. In this paper, we discuss the general problem of building an evidence database by selecting the most useful examples to store while satisfying existing storage requirements. We evaluate three intelligent techniques for this purpose: genetic algorithm-based selection, greedy selection and random mutation hill climbing. These techniques are compared to a random selection strategy used as the baseline. The study is performed with a previously presented CB-CAD system applied for false positive reduction in screening mammograms. The experimental evaluation shows that when the development goal is to maximize the system’s diagnostic performance, the intelligent techniques are able to reduce the size of the evidence database to 37% of the original database by eliminating superfluous and/or detrimental examples while at the same time significantly improving the CAD system’s performance. Furthermore, if the case-base size is a main concern, the total number of examples stored in the system can be reduced to only 2–4% of the original database without a decrease in the diagnostic performance. Comparison of the techniques shows that random mutation hill climbing provides the best balance between the diagnostic performance and computational efficiency when building the evidence database of the CB-CAD system. PMID:18854606
Arenillas, Juan F; Candell-Riera, Jaume; Romero-Farina, Guillermo; Molina, Carlos A; Chacón, Pilar; Aguadé-Bruix, Santiago; Montaner, Joan; de León, Gustavo; Castell-Conesa, Joan; Alvarez-Sabín, José
2005-06-01
Optimization of coronary risk evaluation in stroke patients has been encouraged. The relationship between symptomatic intracranial atherosclerosis and occult coronary artery disease (CAD) has not been evaluated sufficiently. We aimed to investigate the prevalence of silent myocardial ischemia in patients with symptomatic intracranial atherosclerosis and to identify factors associated with its presence. From 186 first-ever transient ischemic attack or ischemic stroke patients with intracranial stenoses, 65 fulfilled selection criteria, including angiographic confirmation of a symptomatic atherosclerotic stenosis and absence of known CAD. All patients underwent a maximal-stress myocardial perfusion single-photon emission computed tomography (SPECT). Lipoprotein(a) [Lp(a)], C-reactive protein, and homocysteine (Hcy) levels were determined before SPECT. Stress-rest SPECT detected reversible myocardial perfusion defects in 34 (52%) patients. Vascular risk factors associated with a pathologic SPECT were hypercholesterolemia (P=0.045), presence of >2 risk factors (P=0.004) and high Lp(a) (P=0.023) and Hcy levels (P=0.018). Ninety percent of patients with high Lp(a) and Hcy levels had a positive SPECT. Existence of a stenosed intracranial internal carotid artery (ICA; odds ratio [OR], 7.22, 2.07 to 25.23; P=0.002) and location of the symptomatic stenosis in vertebrobasilar arteries (OR, 4.89, 1.19 to 20.12; P=0.027) were independently associated with silent myocardial ischemia after adjustment by age, sex, and risk factors. More than 50% of the patients with symptomatic intracranial atherosclerosis and not overt CAD show myocardial perfusion defects on stress-rest SPECT. Stenosed intracranial ICA, symptomatic vertebrobasilar stenosis and presence of high Lp(a) and Hcy levels may characterize the patients at a higher risk for occult CAD.
Aydin Sunbul, Esra; Sunbul, Murat; Gulec, Huseyin
Depression is an independent risk factor in cardiovascular diseases. Changes in the cardiac autonomic functions and pro-inflammatory processes are potential biological factors. Endothelial dysfunction plays an important role in the etiopathogenesis of atherosclerosis. Our objective was to evaluate the impact of major depression on heart rate variability and endothelial dysfunction in patients with stable CAD. The study group included 65 CAD patients with a diagnosis of major depression and 54 CAD patients without major depression. All study population underwent transthoracic echocardiography, measurement of flow mediated dilatation (FMD) and 24-h holter recording for heart rate variability (HRV). Blood samples were drawn to determine the inflammatory parameters. Severity of depressive episode was assessed by Montgomery-Asberg Depression Scale (MADRS). The distribution of age and sex was similar in the patient and control groups (P=0.715, 0.354, respectively). There was no significant difference in medications used between the groups. Echocardiographic parameters were similar between the groups. Inflammatory parameters were also similar between the groups. HRV parameters were significantly lower in the patient group than controls. The absolute FMD value and percentage FMD were significantly lower in the patient group than controls (P<0.001). The MADRS score correlated with pNN50 in both groups (P<0.05), and with FMD in the control group (P<0.001), even after adjusting for age and gender (P<0.001). MADRS score was an independent predictor of pNN50 level, percentage and absolute FMD values regardless of age and gender. Clinician should pay more attention for evaluation of depressive patients with CAD. Copyright © 2016 Elsevier Inc. All rights reserved.
2018-01-01
Background Mindfulness-based art therapy (MBAT) induces emotional relaxation in coronary artery disease (CAD) patients, and is a treatment known to improve psychological stability. The objective of this study was to evaluate the treatment effects of MBAT for CAD patients. Methods A total of 44 CAD patients were selected as participants, 21 patients belonged to a MBAT group, and 23 patients belonged to the control group. The patients in the MBAT group were given 12 sessions of treatments. To measure depression and anxiety, Beck Depression Inventory (BDI) and Trait Anxiety Inventory (TAI) were used. Anger and anger expression were evaluated using the State Trait Anger Expression Inventory (STAXI). The treatment results were analyzed using two-way repeated measures analysis of variance (ANOVA). Results The results showed that significant effects for groups, time, and interaction in the depression (interaction effect, [F(1,36) = 23.15, P < 0.001]; between groups, [F(1,36) = 5.73, P = 0.022]), trait anxiety (interaction effect, [F(1,36) = 13.23, P < 0.001]; between groups, [F(1,36) = 4.38, P = 0.043]), state anger (interaction effect, [F(1,36) = 5.60, P = 0.023]), trait anger (interaction effect, [F(1,36) = 6.93, P = 0.012]; within group, [F(1,36) = 4.73, P = 0.036]), anger control (interaction effect, [F(1,36) = 8.41, P = 0.006]; within group, [F(1,36) = 9.41, P = 0.004]), anger out (interaction effect, [F(1,36) = 6.88, P = 0.012]; within group, [F(1,36) = 13.17, P < 0.001]; between groups, [F(1,36) = 5.62, P = 0.023]), and anger in (interaction effect, [F(1,36) = 32.66, P < 0.001]; within group, [F(1,36) = 25.90, P < 0.001]; between groups, [F(1,36) = 12.44, P < 0.001]). Conclusion MBAT can be seen as an effective treatment method that improves CAD patients' psychological stability. Evaluation of treatment effects using program development and large-scale research for future clinical application is needed. PMID:29542299
Wolak, Arik; Slomka, Piotr J; Fish, Mathews B; Lorenzo, Santiago; Berman, Daniel S; Germano, Guido
2008-06-01
Attenuation correction (AC) for myocardial perfusion SPECT (MPS) had not been evaluated separately in women despite specific considerations in this group because of breast photon attenuation. We aimed to evaluate the performance of AC in women by using automated quantitative analysis of MPS to avoid any bias. Consecutive female patients--134 with a low likelihood (LLk) of coronary artery disease (CAD) and 114 with coronary angiography performed within less than 3 mo of MPS--who were referred for rest-stress electrocardiography-gated 99mTc-sestamibi MPS with AC were considered. Imaging data were evaluated for contour quality control. An additional 50 LLk studies in women were used to create equivalent normal limits for studies with AC and with no correction (NC). An experienced technologist unaware of the angiography and other results performed the contour quality control. All other processing was performed in a fully automated manner. Quantitative analysis was performed with the Cedars-Sinai myocardial perfusion analysis package. All automated segmental analyses were performed with the 17-segment, 5-point American Heart Association model. Summed stress scores (SSS) of > or =3 were considered abnormal. CAD (> or =70% stenosis) was present in 69 of 114 patients (60%). The normalcy rates were 93% for both NC and AC studies. The SSS for patients with CAD and without CAD for NC versus AC were 10.0 +/- 9.0 (mean +/- SD) versus 10.2 +/- 8.5 and 1.6 +/- 2.3 versus 1.8 +/- 2.5, respectively; P was not significant (NS) for all comparisons of NC versus AC. The SSS for LLk patients for NC versus AC were 0.51 +/- 1.0 versus 0.6 +/- 1.1, respectively; P was NS. The specificity for both NC and AC was 73%. The sensitivities for NC and AC were 80% and 81%, respectively, and the accuracies for NC and AC were 77% and 78%, respectively; P was NS for both comparisons. There are no significant diagnostic differences between automated quantitative MPS analyses performed in studies processed with and without AC in women.
Giger, Maryellen L.; Chan, Heang-Ping; Boone, John
2008-01-01
The roles of physicists in medical imaging have expanded over the years, from the study of imaging systems (sources and detectors) and dose to the assessment of image quality and perception, the development of image processing techniques, and the development of image analysis methods to assist in detection and diagnosis. The latter is a natural extension of medical physicists’ goals in developing imaging techniques to help physicians acquire diagnostic information and improve clinical decisions. Studies indicate that radiologists do not detect all abnormalities on images that are visible on retrospective review, and they do not always correctly characterize abnormalities that are found. Since the 1950s, the potential use of computers had been considered for analysis of radiographic abnormalities. In the mid-1980s, however, medical physicists and radiologists began major research efforts for computer-aided detection or computer-aided diagnosis (CAD), that is, using the computer output as an aid to radiologists—as opposed to a completely automatic computer interpretation—focusing initially on methods for the detection of lesions on chest radiographs and mammograms. Since then, extensive investigations of computerized image analysis for detection or diagnosis of abnormalities in a variety of 2D and 3D medical images have been conducted. The growth of CAD over the past 20 years has been tremendous—from the early days of time-consuming film digitization and CPU-intensive computations on a limited number of cases to its current status in which developed CAD approaches are evaluated rigorously on large clinically relevant databases. CAD research by medical physicists includes many aspects—collecting relevant normal and pathological cases; developing computer algorithms appropriate for the medical interpretation task including those for segmentation, feature extraction, and classifier design; developing methodology for assessing CAD performance; validating the algorithms using appropriate cases to measure performance and robustness; conducting observer studies with which to evaluate radiologists in the diagnostic task without and with the use of the computer aid; and ultimately assessing performance with a clinical trial. Medical physicists also have an important role in quantitative imaging, by validating the quantitative integrity of scanners and developing imaging techniques, and image analysis tools that extract quantitative data in a more accurate and automated fashion. As imaging systems become more complex and the need for better quantitative information from images grows, the future includes the combined research efforts from physicists working in CAD with those working on quantitative imaging systems to readily yield information on morphology, function, molecular structure, and more—from animal imaging research to clinical patient care. A historical review of CAD and a discussion of challenges for the future are presented here, along with the extension to quantitative image analysis. PMID:19175137
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giger, Maryellen L.; Chan, Heang-Ping; Boone, John
2008-12-15
The roles of physicists in medical imaging have expanded over the years, from the study of imaging systems (sources and detectors) and dose to the assessment of image quality and perception, the development of image processing techniques, and the development of image analysis methods to assist in detection and diagnosis. The latter is a natural extension of medical physicists' goals in developing imaging techniques to help physicians acquire diagnostic information and improve clinical decisions. Studies indicate that radiologists do not detect all abnormalities on images that are visible on retrospective review, and they do not always correctly characterize abnormalities thatmore » are found. Since the 1950s, the potential use of computers had been considered for analysis of radiographic abnormalities. In the mid-1980s, however, medical physicists and radiologists began major research efforts for computer-aided detection or computer-aided diagnosis (CAD), that is, using the computer output as an aid to radiologists--as opposed to a completely automatic computer interpretation--focusing initially on methods for the detection of lesions on chest radiographs and mammograms. Since then, extensive investigations of computerized image analysis for detection or diagnosis of abnormalities in a variety of 2D and 3D medical images have been conducted. The growth of CAD over the past 20 years has been tremendous--from the early days of time-consuming film digitization and CPU-intensive computations on a limited number of cases to its current status in which developed CAD approaches are evaluated rigorously on large clinically relevant databases. CAD research by medical physicists includes many aspects--collecting relevant normal and pathological cases; developing computer algorithms appropriate for the medical interpretation task including those for segmentation, feature extraction, and classifier design; developing methodology for assessing CAD performance; validating the algorithms using appropriate cases to measure performance and robustness; conducting observer studies with which to evaluate radiologists in the diagnostic task without and with the use of the computer aid; and ultimately assessing performance with a clinical trial. Medical physicists also have an important role in quantitative imaging, by validating the quantitative integrity of scanners and developing imaging techniques, and image analysis tools that extract quantitative data in a more accurate and automated fashion. As imaging systems become more complex and the need for better quantitative information from images grows, the future includes the combined research efforts from physicists working in CAD with those working on quantitative imaging systems to readily yield information on morphology, function, molecular structure, and more--from animal imaging research to clinical patient care. A historical review of CAD and a discussion of challenges for the future are presented here, along with the extension to quantitative image analysis.« less
Integrated geometry and grid generation system for complex configurations
NASA Technical Reports Server (NTRS)
Akdag, Vedat; Wulf, Armin
1992-01-01
A grid generation system was developed that enables grid generation for complex configurations. The system called ICEM/CFD is described and its role in computational fluid dynamics (CFD) applications is presented. The capabilities of the system include full computer aided design (CAD), grid generation on the actual CAD geometry definition using robust surface projection algorithms, interfacing easily with known CAD packages through common file formats for geometry transfer, grid quality evaluation of the volume grid, coupling boundary condition set-up for block faces with grid topology generation, multi-block grid generation with or without point continuity and block to block interface requirement, and generating grid files directly compatible with known flow solvers. The interactive and integrated approach to the problem of computational grid generation not only substantially reduces manpower time but also increases the flexibility of later grid modifications and enhancements which is required in an environment where CFD is integrated into a product design cycle.
Hiwasa, Takaki; Zhang, Xiao-Meng; Kimura, Risa; Ohno, Mikiko; Chen, Po-Min; Nishi, Eiichiro; Ono, Koh; Kimura, Takeshi; Kamitsukasa, Ikuo; Wada, Takeshi; Aotsuka, Akiyo; Mine, Seiichiro; Takizawa, Hirotaka; Kashiwado, Koichi; Takemoto, Minoru; Kobayashi, Kazuki; Kawamura, Harukiyo; Ishibashi, Ryoichi; Yokote, Koutaro; Nakamura, Rika; Tomiyoshi, Go; Shinmen, Natsuko; Kuroda, Hideyuki
2016-01-01
Adiponectin secreted from the adipocytes plays pleiotropic, anti-atherosclerotic roles, such as enhancement of insulin secretion and an increase in energy expenditure. The measurement of levels of circulating adiponectin is useful to evaluate the progression of atherosclerosis-related diseases, such as coronary artery disease (CAD), cerebral infarction (CI) and diabetes mellitus (DM). We examined the serum antibody levels against recombinant adiponectin protein via the amplified luminescent proximity homogeneous assay-linked immunosorbent assay (AlphaLISA) method. The results revealed that the antibody levels were significantly higher in patients with CAD, CI and type 2 DM, than in healthy donors. Receiver operating curve analysis showed that the sensitivity was in a range of 41–48% for CAD, CI and DM. Thus, the serum anti-adiponectin antibody levels could be a common marker for atherosclerosis-related diseases. PMID:28936256
Baroudi, Kusai; Ibraheem, Shukran Nasser
2015-01-01
Background: This paper aimed to evaluate the application of computer-aided design and computer-aided manufacturing (CAD-CAM) technology and the factors that affect the survival of restorations. Materials and Methods: A thorough literature search using PubMed, Medline, Embase, Science Direct, Wiley Online Library and Grey literature were performed from the year 2004 up to June 2014. Only relevant research was considered. Results: The use of chair-side CAD/CAM systems is promising in all dental branches in terms of minimizing time and effort made by dentists, technicians and patients for restoring and maintaining patient oral function and aesthetic, while providing high quality outcome. Conclusion: The way of producing and placing the restorations made with the chair-side CAD/CAM (CEREC and E4D) devices is better than restorations made by conventional laboratory procedures. PMID:25954082
Rustemeyer, Jan; Melenberg, Alex; Sari-Rieger, Aynur
2014-12-01
This study aims to evaluate the additional costs incurred by using a computer-aided design/computer-aided manufacturing (CAD/CAM) technique for reconstructing maxillofacial defects by analyzing typical cases. The medical charts of 11 consecutive patients who were subjected to the CAD/CAM technique were considered, and invoices from the companies providing the CAD/CAM devices were reviewed for every case. The number of devices used was significantly correlated with cost (r = 0.880; p < 0.001). Significant differences in mean costs were found between cases in which prebent reconstruction plates were used (€3346.00 ± €29.00) and cases in which they were not (€2534.22 ± €264.48; p < 0.001). Significant differences were also obtained between the costs of two, three and four devices, even when ignoring the cost of reconstruction plates. Additional fees provided by statutory health insurance covered a mean of 171.5% ± 25.6% of the cost of the CAD/CAM devices. Since the additional fees provide financial compensation, we believe that the CAD/CAM technique is suited for wide application and not restricted to complex cases. Where additional fees/funds are not available, the CAD/CAM technique might be unprofitable, so the decision whether or not to use it remains a case-to-case decision with respect to cost versus benefit. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Bohner, Lauren Oliveira Lima; Neto, Pedro Tortamano; Ahmed, Ahad Shahid; Mori, Matsuyoshi; Laganá, Dalva Cruz; Sesma, Newton
2016-07-01
The aim of this review was to update the literature with regard to the digital methods available by CEREC Chairside system to register and design the occlusion, to report their efficacy and technical innovations in the field of Restorative Dentistry. A search strategy was performed using the key-words: "virtual articulator," or "CAD-CAM and occlusal recording," or "CAD-CAM and occlusion register," or "CAD-CAM and occlusal contacts," or "CAD-CAM and prosthesis." Inclusion criteria comprised studies evaluating the use of digital methods available by CEREC System for occlusal registration and design during prosthodontics treatment. PubMed and Cochrane library and reference lists were searched up to January 2016. The search resulted in 280 articles after removing duplicates. Subsequently, 233 records were excluded and 49 studies were selected for reading in full. Eleven articles were considered eligible for the systematic review (4 in vitro and 7 clinical studies). Scientific evidence suggests that digital methods were accurate to register and design the occlusion of dental prostheses. Nevertheless, further clinical studies are required to establish a conclusion with regard to its accuracy in prosthodontics treatment. Digital technologies allow the design of occlusal surfaces of CAD-CAM fabricated prostheses using innovative approaches. This systematic review aimed to update the literature to help dentists determine the most appropriate digital method to register and design the occlusal surface of CAD-CAM crowns. (J Esthet Restor Dent 28:208-220, 2016). © 2016 Wiley Periodicals, Inc.
Shear Bond Strength of Repair Systems to New CAD/CAM Restorative Materials.
Üstün, Özlem; Büyükhatipoğlu, Işıl Keçik; Seçilmiş, Aslı
2016-11-23
To evaluate the bond strength of repair systems (Ceramic Repair, Clearfil Repair) to computer-aided design/computer-assisted machining (CAD/CAM) restorative materials (IPS e.max CAD, Vita Suprinity, Vita Enamic, Lava Ultimate). Thermally aged CAD/CAM restorative material specimens (5000 cycles between 5°C and 55°C) were randomly divided into two groups according to the repair system: Ceramic Repair (37% phosphoric acid + Monobond-S + Heliobond + Tetric N Ceram) or Clearfil Repair (40% phosphoric acid + mixture of Clearfil Porcelain Bond Activator and Clearfil SE Bond Primer + Clearfil SE Bond + Filtek Z250). The resin composite was light-cured on conditioned specimens. All specimens were stored in distilled water at 37°C for 24 hours and then additionally aged for 5000 thermal cycles. The shear bond strength test was performed using a universal testing machine (0.5 mm/min). Two-way ANOVA was used to detect significance differences according to the CAD/CAM material and composite repair system factors. Subgroup analyses were conducted using the least significant difference post-hoc test. The results of two-way ANOVA indicated that bond strength values varied according to the restorative materials (p < 0.05). No significant differences were observed between the CAD/CAM restorative materials (p > 0.05), except in the Vita Suprinity group (p < 0.05). Moreover, no differences were observed between the repair systems. Both the Clearfil and Ceramic repair systems used in the study allow for successful repairs. © 2016 by the American College of Prosthodontists.
NASA Astrophysics Data System (ADS)
Ma, Kevin C.; Zhang, Aifeng; Moin, Paymann; Fleshman, Mariam; Vachon, Linda; Liu, Brent; Huang, H. K.
2009-02-01
Bone age assessment is a radiological procedure to evaluate a child's bone age based on his or her left-hand x-ray image. The current standard is to match patient's hand with Greulich & Pyle hand atlas, which is outdated by 50 years and only uses subjects from one region and one ethnicity. To improve bone age assessment accuracy for today's children, an automated race- and gender-specific bone age assessment (BAA) system has been developed in IPILab. 1390 normal left-hand x-ray images have been collected at Children's Hospital of Los Angeles (CHLA) to form the digital hand atlas (DHA). DHA includes both male and female children of ages one to eighteen and of four ethnic groups: African American, Asian American, Caucasian, and Hispanic. In order to apply DHA and BAA CAD into a clinical environment, a web-based BAA CAD system and graphical user interface (GUI) has been implemented in Women and Children's Hospital at Los Angeles County (WCH-LAC). A CAD server has been integrated in WCH's PACS environment, and a clinical validation workflow has been designed for radiologists, who compare CAD readings with G&P readings and determine which reading is more suited for a certain case. Readings are logged in database and analyzed to assess BAA CAD performance in a clinical setting. The result is a successful installation of web-based BAA CAD system in a clinical setting.
Christiansen, Andrew R; Shorti, Rami M; Smith, Cory D; Prows, William C; Bishoff, Jay T
2018-05-01
Despite the increasing use of advanced 3D imaging techniques and 3D printing, these techniques have not yet been comprehensively compared in a surgical setting. The purpose of this study is to explore the effectiveness of five different advanced imaging modalities during a complex renal surgical procedure. A patient with a horseshoe kidney and multiple large, symptomatic stones that had failed Extracorporeal Shock Wave Lithotripsy (ESWL) and ureteroscopy treatment was used for this evaluation. CT data were used to generate five different imaging modalities, including a 3D printed model, three different volume rendered models, and a geometric CAD model. A survey was used to evaluate the quality and breadth of the imaging modalities during four different phases of the laparoscopic procedure. In the case of a complex kidney procedure, the CAD model, 3D print, volume render on an autostereoscopic 3D display, interactive and basic volume render models demonstrated added insight and complemented the surgical procedure. CAD manual segmentation allowed tissue layers and/or kidney stones to be made colorful and semi-transparent, allowing easier navigation through abnormal vasculature. The 3D print allowed for simultaneous visualization of renal pelvis and surrounding vasculature. Our preliminary exploration indicates that various advanced imaging modalities, when properly utilized and supported during surgery, can be useful in complementing the CT data and laparoscopic display. This study suggests that various imaging modalities, such as ones utilized in this case, can be beneficial intraoperatively depending on the surgical step involved and may be more helpful than 3D printed models. We also present factors to consider when evaluating advanced imaging modalities during complex surgery.
Rani, Sapna; Verma, Mahesh; Gill, Shubhra; Gupta, Rekha
2016-01-01
Background/Purpose: The aim of this study was to compare the shear bond strength of computer aided design/computer aided machined ceramic (CAD/CAM), pressable ceramic, and milled metal implant copings on abutment and the effect of surface conditioning on bonding strength. Materials and Methods: A total of 90 test samples were fabricated on three titanium abutments. Among 90 test samples, 30 copings were fabricated by CAD/CAM, 30 by pressable, and 30 by milling of titanium metal. These 30 test samples in each group were further subdivided equally for surface treatment. Fifteen out of 30 test samples in each group were surface conditioned with airborne particle abrasion. All the 90 test samples were luted on abutment with glass ionomer cement. Bonding strength was evaluated for all the samples using universal testing machine at a crosshead speed of 5 mm/min. The results obtained were compared and evaluated using one-way ANOVA with post-hoc and unpaired t-test at a significance level of 0.05. Results: The mean difference for CAD/CAM surface conditioned subgroup was 1.28 ± 0.12, for nonconditioned subgroup was 1.20 ± 0.11. The mean difference for pressable surface conditioned subgroup was 1.18 ± 0.04, and for nonconditioned subgroup was 0.75 ± 0.28. The mean difference for milled metal surface conditioned subgroup was 2.57 ± 0.58, and for nonconditioned subgroup was 1.49 ± 0.15. Conclusions: On comparison of bonding strength, milled metal copings had an edge over the other two materials, and surface conditioning increased the bond strength. PMID:27141163
NASA Astrophysics Data System (ADS)
Boehm, Holger F.; Fischer, Tanja; Riosk, Dororthea; Britsch, Stefanie; Reiser, Maximilian
2008-03-01
With an estimated life-time-risk of about 10%, breast cancer is the most common cancer among women in western societies. Extensive mammography-screening programs have been implemented for diagnosis of the disease at an early stage. Several algorithms for computer-aided detection (CAD) have been proposed to help radiologists manage the increasing number of mammographic image-data and identify new cases of cancer. However, a major issue with most CAD-solutions is the fact that performance strongly depends on the structure and density of the breast tissue. Prior information about the global tissue quality in a patient would be helpful for selecting the most effective CAD-approach in order to increase the sensitivity of lesion-detection. In our study, we propose an automated method for textural evaluation of digital mammograms using the Minkowski Functionals in 2D. 80 mammograms are consensus-classified by two experienced readers as fibrosis, involution/atrophy, or normal. For each case, the topology of graylevel distribution is evaluated within a retromamillary image-section of 512 x 512 pixels. In addition, we obtain parameters from the graylevel-histogram (20th percentile, median and mean graylevel intensity). As a result, correct classification of the mammograms based on the densitometic parameters is achieved in between 38 and 48%, whereas topological analysis increases the rate to 83%. The findings demonstrate the effectiveness of the proposed algorithm. Compared to features obtained from graylevel histograms and comparable studies, we draw the conclusion that the presented method performs equally good or better. Our future work will be focused on the characterization of the mammographic tissue according to the Breast Imaging Reporting and Data System (BI-RADS). Moreover, other databases will be tested for an in-depth evaluation of the efficiency of our proposal.
A computerized scheme for lung nodule detection in multiprojection chest radiography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guo Wei; Li Qiang; Boyce, Sarah J.
2012-04-15
Purpose: Our previous study indicated that multiprojection chest radiography could significantly improve radiologists' performance for lung nodule detection in clinical practice. In this study, the authors further verify that multiprojection chest radiography can greatly improve the performance of a computer-aided diagnostic (CAD) scheme. Methods: Our database consisted of 59 subjects, including 43 subjects with 45 nodules and 16 subjects without nodules. The 45 nodules included 7 real and 38 simulated ones. The authors developed a conventional CAD scheme and a new fusion CAD scheme to detect lung nodules. The conventional CAD scheme consisted of four steps for (1) identification ofmore » initial nodule candidates inside lungs, (2) nodule candidate segmentation based on dynamic programming, (3) extraction of 33 features from nodule candidates, and (4) false positive reduction using a piecewise linear classifier. The conventional CAD scheme processed each of the three projection images of a subject independently and discarded the correlation information between the three images. The fusion CAD scheme included the four steps in the conventional CAD scheme and two additional steps for (5) registration of all candidates in the three images of a subject, and (6) integration of correlation information between the registered candidates in the three images. The integration step retained all candidates detected at least twice in the three images of a subject and removed those detected only once in the three images as false positives. A leave-one-subject-out testing method was used for evaluation of the performance levels of the two CAD schemes. Results: At the sensitivities of 70%, 65%, and 60%, our conventional CAD scheme reported 14.7, 11.3, and 8.6 false positives per image, respectively, whereas our fusion CAD scheme reported 3.9, 1.9, and 1.2 false positives per image, and 5.5, 2.8, and 1.7 false positives per patient, respectively. The low performance of the conventional CAD scheme may be attributed to the high noise level in chest radiography, and the small size and low contrast of most nodules. Conclusions: This study indicated that the fusion of correlation information in multiprojection chest radiography can markedly improve the performance of CAD scheme for lung nodule detection.« less
Teaching CAD on the Apple Computer.
ERIC Educational Resources Information Center
Norton, Robert L.
1984-01-01
Describes a course designed to teach engineers how to accomplish computer graphics techniques on a limited scale with the Apple computer. The same mathematics and program code will also function for larger and more complex computers. Course content, instructional strategies, student evaluation, and recommendations are considered. (JN)
Shibata, Shizuma; Vieira, Luiz Clovis Cardoso; Baratieri, Luiz Narciso; Fu, Jiale; Hoshika, Shuhei; Matsuda, Yasuhiro; Sano, Hidehiko
2016-01-01
The purpose of this study was to evaluate the µTBS (microtensile bond strength) of currently available self-etching adhesives with an experimental self-etch adhesive in normal and caries-affected dentin, using a portable hardness measuring device, in order to standardize dentin Knoop hardness. Normal (ND) and caries-affected dentin (CAD) were obtained from twenty human molars with class II natural caries. The following adhesive systems were tested: Mega Bond (MB), a 2-step self-etching adhesive; MTB-200 (MTB), an experimental 1-step self-etching adhesive (1-SEA), and two commercially available one-step self-etching systems, G-Bond Plus (GB) and Adper Easy Bond (EB). MB-ND achieved the highest µTBS (p<0.05). The mean µTBS was statistically lower in CAD than in ND for all adhesives tested (p<0.05), and the 2-step self-etch adhesive achieved better overall performance than the 1-step self-etch adhesives.
Impact of background on color, transmittance, and fluorescence of leucite based ceramics.
Rafael, Caroline Freitas; Güth, Jan-Frederik; Kauling, Ana Elisa Colle; Cesar, Paulo Francisco; Volpato, Claudia Angelo Mazieiro; Liebermann, Anja
2017-07-26
This study evaluated the impact of tooth shade on differences in color (∆E), lightness (∆L), chromaticity coordinates a*/b* (∆a and ∆b), transmittance and the degree of fluorescence of CAD/CAM leucite based ceramic (LBC). Ten disks were fabricated of LBC; Empress CAD, A2, thickness of 1.5 mm and eight disks of resin-nano-ceramic (RNC; Lava Ultimate) in different colors to simulate variations in substrate shade. The associations of LBC disks with different color substrates were analyzed with a spectrophotometer; ∆E, ∆L*, ∆a*, ∆b*, and transmittance were measured and calculated. Fluorescence was evaluated with a fluorescence system (Fluorescence System, Biopdi). All substrate shades influenced the optical properties of LBC, with regard to color, luminosity, coordinate a* and b*, transmittance, and fluorescence (p<0.001). Substrate colors with high saturation (A3.5 and C2) presented highest impact, whereas colors with lowest saturations (BL, B1) showed less impact. Substrate color influenced the optical properties of ceramic restorations.
NASA Astrophysics Data System (ADS)
Vencloviene, J.; Babarskiene, R.; Milvidaite, I.; Kubilius, R.; Stasionyte, J.
2013-12-01
Some evidence indicates the deterioration of the cardiovascular system during space storms. It is plausible that the space weather conditions during and after hospital admission may affect the risk of coronary events in patients with acute coronary syndromes (ACS). We analyzed the data of 1400 ACS patients who were admitted to the Hospital Lithuanian University of Health Sciences, and who survived for more than 4 days. We evaluated the associations between geomagnetic storms (GS), solar proton events (SPE), and solar flares (SF) that occurred 0-3 days before and after hospital admission and the risk of cardiovascular death (CAD), non-fatal ACS, and coronary artery bypass grafting (CABG) during a period of 1 year; the evaluation was based on the multivariate logistic model, controlling for clinical data. After adjustment for clinical variables, GS occurring in conjunction with SF 1 day before admission increased the risk of CAD by over 2.5 times. GS 2 days after SPE occurred 1 day after admission increased the risk of CAD and CABG by over 2.8 times. The risk of CABG increased by over 2 times in patients admitted during the day of GS and 1 day after SPE. The risk of ACS was by over 1.63 times higher for patients admitted 1 day before or after solar flares.
Mazurowski, Maciej A.; Zurada, Jacek M.; Tourassi, Georgia D.
2009-01-01
Ensemble classifiers have been shown efficient in multiple applications. In this article, the authors explore the effectiveness of ensemble classifiers in a case-based computer-aided diagnosis system for detection of masses in mammograms. They evaluate two general ways of constructing subclassifiers by resampling of the available development dataset: Random division and random selection. Furthermore, they discuss the problem of selecting the ensemble size and propose two adaptive incremental techniques that automatically select the size for the problem at hand. All the techniques are evaluated with respect to a previously proposed information-theoretic CAD system (IT-CAD). The experimental results show that the examined ensemble techniques provide a statistically significant improvement (AUC=0.905±0.024) in performance as compared to the original IT-CAD system (AUC=0.865±0.029). Some of the techniques allow for a notable reduction in the total number of examples stored in the case base (to 1.3% of the original size), which, in turn, results in lower storage requirements and a shorter response time of the system. Among the methods examined in this article, the two proposed adaptive techniques are by far the most effective for this purpose. Furthermore, the authors provide some discussion and guidance for choosing the ensemble parameters. PMID:19673196
Schönberger, Joana; Erdelt, Kurt-Jürgen; Bäumer, Daniel; Beuer, Florian
2017-11-01
The purpose of this in vitro study was to compare the precision of fit of frameworks milled from semi-sintered regular zirconia and high-translucent (HT) zirconia blanks, fabricated with two different CAD/CAM systems. Three-unit, posterior fixed dental prostheses (FDP) frameworks were fabricated for standardized dies (n = 11) with two different laboratory computer-aided design (CAD)/computer-aided manufacturing (CAM) systems (Cercon/Ceramill). The replica technique was used to evaluate the marginal and internal fit under an optical microscope. Evaluation of the data was performed according to prior studies at a level of significance of 5%. The systems showed a statistically significant influence on the internal fit of the frameworks (p ≤ 0.001) and on the marginal fit (p < 0.001). The type of material showed no influence on the marginal fit for the Cercon system (p = 0.636) and on the marginal fit (p = 0.064) and the internal fit (p = 0.316) for the Ceramill system, while regular zirconia from Cercon showed higher internal values than HT zirconia (p = 0.016). Both investigated systems showed clinically acceptable values within the limitations of this in vitro study. However, one showed less internal accuracy when regular zirconia was used.
Effect of segmentation algorithms on the performance of computerized detection of lung nodules in CT
Guo, Wei; Li, Qiang
2014-01-01
Purpose: The purpose of this study is to reveal how the performance of lung nodule segmentation algorithm impacts the performance of lung nodule detection, and to provide guidelines for choosing an appropriate segmentation algorithm with appropriate parameters in a computer-aided detection (CAD) scheme. Methods: The database consisted of 85 CT scans with 111 nodules of 3 mm or larger in diameter from the standard CT lung nodule database created by the Lung Image Database Consortium. The initial nodule candidates were identified as those with strong response to a selective nodule enhancement filter. A uniform viewpoint reformation technique was applied to a three-dimensional nodule candidate to generate 24 two-dimensional (2D) reformatted images, which would be used to effectively distinguish between true nodules and false positives. Six different algorithms were employed to segment the initial nodule candidates in the 2D reformatted images. Finally, 2D features from the segmented areas in the 24 reformatted images were determined, selected, and classified for removal of false positives. Therefore, there were six similar CAD schemes, in which only the segmentation algorithms were different. The six segmentation algorithms included the fixed thresholding (FT), Otsu thresholding (OTSU), fuzzy C-means (FCM), Gaussian mixture model (GMM), Chan and Vese model (CV), and local binary fitting (LBF). The mean Jaccard index and the mean absolute distance (Dmean) were employed to evaluate the performance of segmentation algorithms, and the number of false positives at a fixed sensitivity was employed to evaluate the performance of the CAD schemes. Results: For the segmentation algorithms of FT, OTSU, FCM, GMM, CV, and LBF, the highest mean Jaccard index between the segmented nodule and the ground truth were 0.601, 0.586, 0.588, 0.563, 0.543, and 0.553, respectively, and the corresponding Dmean were 1.74, 1.80, 2.32, 2.80, 3.48, and 3.18 pixels, respectively. With these segmentation results of the six segmentation algorithms, the six CAD schemes reported 4.4, 8.8, 3.4, 9.2, 13.6, and 10.4 false positives per CT scan at a sensitivity of 80%. Conclusions: When multiple algorithms are available for segmenting nodule candidates in a CAD scheme, the “optimal” segmentation algorithm did not necessarily lead to the “optimal” CAD detection performance. PMID:25186393
Lee, Seung-Hyun; Shin, Kihyuk; Park, Sungha; Kang, Seok-Min; Choi, Donghoon
2015-01-01
Purpose Elastin is a major arterial structural protein, and elastin-derived peptides are related to arterial change. We previously reported on a novel assay developed using aortic elastin peptides; however, its clinical implications remain unclear. In this study, we assessed whether anti-elastin antibody titers reflect the risk of coronary artery disease (CAD) or its characteristics. Materials and Methods We included 174 CAD patients and 171 age- and sex-matched controls. Anti-elastin antibody titers were quantified by enzyme-linked immunosorbent assay. Parameters of arterial stiffness, including the augmentation index (AI) and heart-to-femoral pulse wave velocity (hfPWV), were measured non-invasively. The clinical and angiographic characteristics of CAD patients were also evaluated. Associations between anti-elastin levels and vascular characteristics were examined by linear regression analysis. Results The median blood level of anti-elastin was significantly lower in the CAD group than in the controls [197 arbitrary unit (a.u.) vs. 63 a.u., p<0.001]. Levels of anti-elastin were significantly lower in men and in subjects with hypertension, diabetes mellitus, hyperlipidemia, or high hfPWV. Nevertheless, anti-elastin levels were not dependent on atherothrombotic events or the angiographic severity of CAD. In a multivariate analysis, male sex (β=-0.38, p<0.001), diabetes mellitus (β=-0.62, p<0.001), hyperlipidemia (β=-0.29, p<0.001), and AI (β=-0.006, p=0.02) were ultimately identified as determinants of anti-elastin levels. Conclusion Lower levels of anti-elastin are related to CAD. The association between antibody titers and CAD is linked to arterial stiffness rather than the advancement of atherosclerosis. PMID:26446635
Choi, Young Jun; Baek, Jung Hwan; Park, Hye Sun; Shim, Woo Hyun; Kim, Tae Yong; Shong, Young Kee; Lee, Jeong Hyun
2017-04-01
An initial clinical assessment is described of a new, commercially available, computer-aided diagnosis (CAD) system using artificial intelligence (AI) for thyroid ultrasound, and its performance is evaluated in the diagnosis of malignant thyroid nodules and categorization of nodule characteristics. Patients with thyroid nodules with decisive diagnosis, whether benign or malignant, were consecutively enrolled from November 2015 to February 2016. An experienced radiologist reviewed the ultrasound image characteristics of the thyroid nodules, while another radiologist assessed the same thyroid nodules using the CAD system, providing ultrasound characteristics and a diagnosis of whether nodules were benign or malignant. The diagnostic performance and agreement of US characteristics between the experienced radiologist and the CAD system were compared. In total, 102 thyroid nodules from 89 patients were included; 59 (57.8%) were benign and 43 (42.2%) were malignant. The CAD system showed a similar sensitivity as the experienced radiologist (90.7% vs. 88.4%, p > 0.99), but a lower specificity and a lower area under the receiver operating characteristic (AUROC) curve (specificity: 74.6% vs. 94.9%, p = 0.002; AUROC: 0.83 vs. 0.92, p = 0.021). Classifications of the ultrasound characteristics (composition, orientation, echogenicity, and spongiform) between radiologist and CAD system were in substantial agreement (κ = 0.659, 0.740, 0.733, and 0.658, respectively), while the margin showed a fair agreement (κ = 0.239). The sensitivity of the CAD system using AI for malignant thyroid nodules was as good as that of the experienced radiologist, while specificity and accuracy were lower than those of the experienced radiologist. The CAD system showed an acceptable agreement with the experienced radiologist for characterization of thyroid nodules.
Özparpucu, Merve; Gierlinger, Notburga; Burgert, Ingo; Van Acker, Rebecca; Vanholme, Ruben; Boerjan, Wout; Pilate, Gilles; Déjardin, Annabelle; Rüggeberg, Markus
2018-04-01
CAD-deficient poplars enabled studying the influence of altered lignin composition on mechanical properties. Severe alterations in lignin composition did not influence the mechanical properties. Wood represents a hierarchical fiber-composite material with excellent mechanical properties. Despite its wide use and versatility, its mechanical behavior has not been entirely understood. It has especially been challenging to unravel the mechanical function of the cell wall matrix. Lignin engineering has been a useful tool to increase the knowledge on the mechanical function of lignin as it allows for modifications of lignin content and composition and the subsequent studying of the mechanical properties of these transgenics. Hereby, in most cases, both lignin composition and content are altered and the specific influence of lignin composition has hardly been revealed. Here, we have performed a comprehensive micromechanical, structural, and spectroscopic analysis on xylem strips of transgenic poplar plants, which are downregulated for cinnamyl alcohol dehydrogenase (CAD) by a hairpin-RNA-mediated silencing approach. All parameters were evaluated on the same samples. Raman microscopy revealed that the lignin of the hpCAD poplars was significantly enriched in aldehydes and reduced in the (relative) amount of G-units. FTIR spectra indicated pronounced changes in lignin composition, whereas lignin content was not significantly changed between WT and the hpCAD poplars. Microfibril angles were in the range of 18°-24° and were not significantly different between WT and transgenics. No significant changes were observed in mechanical properties, such as tensile stiffness, ultimate stress, and yield stress. The specific findings on hpCAD poplar allowed studying the specific influence of lignin composition on mechanics. It can be concluded that the changes in lignin composition in hpCAD poplars did not affect the micromechanical tensile properties.
Candia, Roberto; Naimark, David; Sander, Beate; Nguyen, Geoffrey C
2017-11-01
Postoperative recurrence of Crohn's disease is common. This study sought to assess whether the postoperative management should be based on biological therapy alone or combined with thiopurines and whether the therapy should be started immediately after surgery or guided by either endoscopic or clinical recurrence. A Markov model was developed to estimate expected health outcomes in quality-adjusted life years (QALYs) and costs in Canadian dollars (CAD$) accrued by hypothetical patients with high recurrence risk after ileocolic resection. Eight strategies of postoperative management were evaluated. A lifetime time horizon, an annual discount rate of 5%, a societal perspective, and a cost-effectiveness threshold of 50,000 CAD$/QALY were assumed. Deterministic and probabilistic sensitivity analyses were conducted. The model was validated against randomized trials and historical cohorts. Three strategies dominated the others: endoscopy-guided full step-up therapy (14.80 QALYs, CAD$ 462,180), thiopurines immediately post-surgery plus endoscopy-guided biological step-up therapy (14.89 QALYs, CAD$ 464,099) and combination therapy immediately post-surgery (14.94 QALYs, CAD$ 483,685). The second strategy was the most cost-effective, assuming a cost-effectiveness threshold of 50,000 CAD$/QALY. Probabilistic sensitivity analysis showed that the second strategy has the highest probability of being the optimal alternative in all comparisons at cost-effectiveness thresholds from 30,000 to 100,000 CAD$/QALY. The strategies guided only by clinical recurrence and those using biologics alone were dominated. According to this decision analysis, thiopurines immediately after surgery and addition of biologics guided by endoscopic recurrence is the optimal strategy of postoperative management in patients with Crohn's disease with high risk of recurrence (see Video Abstract, Supplemental Digital Content 1, http://links.lww.com/IBD/B654).
Pelletier, Roxanne; Bacon, Simon L; Arsenault, André; Dupuis, Jocelyn; Laurin, Catherine; Blais, Lucie; Lavoie, Kim L
2015-12-15
To assess whether depression and anxiety increase the risk of mortality and major adverse cardiovascular events (MACE), among patients with and without coronary artery disease (CAD). DECADE (Depression Effects on Coronary Artery Disease Events) is a prospective observational study of 2390 patients referred at the Montreal Heart Institute. Patients were followed for 8.8 years, between 1998 and 2009. Depression and anxiety were assessed using a psychiatric interview (Primary Care Evaluation of Mental Disorders, PRIME-MD). Outcomes data were obtained from Quebec provincial databases. All-cause mortality and MACE. After adjustment for covariates, patients with depression were at increased risks of all-cause mortality (relative risk (RR)=2.84; 95% CI 1.25 to 6.49) compared with patients without depression. Anxiety was not associated with increased mortality risks (RR=0.86; 95% CI 0.31 to 2.36). When patients were stratified according to CAD status, depression increased the risk of mortality among patients with no CAD (RR=4.39; 95% CI 1.12 to 17.21), but not among patients with CAD (RR=2.32; 95% CI 0.78 to 6.88). Neither depression nor anxiety was associated with MACE among patients with or without CAD. Depression, but not anxiety, was an independent risk factor for all-cause mortality in patients without CAD. The present study contributes to a better understanding of the relative and unique role of depression versus anxiety among patients with versus without CAD. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Effectiveness of computer aided detection for solitary pulmonary nodules
NASA Astrophysics Data System (ADS)
Yan, Jiayong; Li, Wenjie; Du, Xiangying; Lu, Huihai; Xu, Jianrong; Xu, Mantao; Rong, Dongdong
2009-02-01
This study is to investigate the incremental effect of using a high performance computer-aided detection (CAD) system in detection of solitary pulmonary nodules in chest radiographs. The Kodak Chest CAD system was evaluated by a panel of six radiologists at different levels of experience. The observer study consisted of two independent phases: readings without CAD and readings with assistance of CAD. The study was conducted over a set of chest radiographs comprising 150 cancer cases and 150 cancer-free cases. The actual sensitivity of the CAD system is 72% with 3.7 false positives per case. Receiver operating characteristic (ROC) analysis was used to assess the overall observer performance. The AUZ (area under ROC curve) showed a significantly improvement (P=0.0001) from 0.844 to 0.884 after using CAD. The ROC analysis was also applied for observer performances on nodules in different sizes and visibilities. The average AUZs are improved from 0.798 to 0.835 (P=0.0003) for 5-10mm nodules, 0.853 to 0.907 (P=0.001) for 10-15mm nodules, 0.864 to 0.897 (P=0.051) for 15-20 mm nodules and 0.859 to 0.896 (P=0.0342) for 20-30mm nodules, respectively. For different visibilities, the average AUZs are improved from 0.886 to 0.915 (P=0.0337), 0.803 to 0.840 (P=0.063), 0.830 to 0.893 (P=0.0001), and 0.813 to 0.847 (P=0.152), for nodules clearly visible, hidden by ribs, partially overlap with ribs, and overlap with other structures, respectively. These results showed that observer performance could be greatly improved when the CAD system is employed as a second reader, especially for small nodules and nodules occluded by ribs.
Shimabukuro, Michio; Hirata, Yoichiro; Tabata, Minoru; Dagvasumberel, Munkhbaatar; Sato, Hiromi; Kurobe, Hirotsugu; Fukuda, Daiju; Soeki, Takeshi; Kitagawa, Tetsuya; Takanashi, Shuichiro; Sata, Masataka
2013-05-01
The impact of epicardial adipose tissue (EAT) over abdominal or overall adiposity on coronary artery disease (CAD) is currently unknown. We compared the association among EAT volume (EATV), cytokine/adipocytokine profiles in EAT and subcutaneous fat, and atherogenic CAD. Paired samples were obtained from EAT and subcutaneous adipose tissue during elective cardiac surgery for CAD (n=50) or non-CAD (n=50). EATV was the sum of cross-sectional EAT areas, and visceral and subcutaneous fat areas were determined at the umbilicus level on computed tomography scans. CD68(+), CD11c(+), and CD206(+) cells were counted using immunohistochemical staining. Cytokine/adipocytokine expression was evaluated using quantitative real-time polymerase chain reaction. Multivariate analysis indicated that male sex, age, diabetes mellitus, high triglycerides, and low high-density lipoprotein cholesterol, and EATV index (EATV/body surface area, cm(3)/m(2)) were significant CAD predictors (corrected R(2)=0.401; P<0.001); visceral fat area, hypertension, smoking, low-density lipoprotein cholesterol (140 mg/dL [3.63 mmol/L]) or statin use were not predictors. The EATV index positively correlated with the CD68(+) and CD11c(+) cell numbers and nucleotide-binding domain, leucine-rich-containing family, pyrin domain-containing-3 (NLRP3), interleukin-1β, and interleukin-1R expression; and negatively correlated with adiponectin expression in EAT. A multivariate analysis model, including CD68(+) cells and interleukin-1β, and adiponectin expression in EAT strongly predicted CAD (corrected R(2)=0.756; P<0.001). EATV and macrophage and cytokine/adipocytokine signals in EAT strongly correlated with CAD. Our findings suggest that EATV and adipocytokine imbalance are strongly linked to human coronary atherosclerosis.
Nomura, Yukihiro; Higaki, Toru; Fujita, Masayo; Miki, Soichiro; Awaya, Yoshikazu; Nakanishi, Toshio; Yoshikawa, Takeharu; Hayashi, Naoto; Awai, Kazuo
2017-02-01
This study aimed to evaluate the effects of iterative reconstruction (IR) algorithms on computer-assisted detection (CAD) software for lung nodules in ultra-low-dose computed tomography (ULD-CT) for lung cancer screening. We selected 85 subjects who underwent both a low-dose CT (LD-CT) scan and an additional ULD-CT scan in our lung cancer screening program for high-risk populations. The LD-CT scans were reconstructed with filtered back projection (FBP; LD-FBP). The ULD-CT scans were reconstructed with FBP (ULD-FBP), adaptive iterative dose reduction 3D (AIDR 3D; ULD-AIDR 3D), and forward projected model-based IR solution (FIRST; ULD-FIRST). CAD software for lung nodules was applied to each image dataset, and the performance of the CAD software was compared among the different IR algorithms. The mean volume CT dose indexes were 3.02 mGy (LD-CT) and 0.30 mGy (ULD-CT). For overall nodules, the sensitivities of CAD software at 3.0 false positives per case were 78.7% (LD-FBP), 9.3% (ULD-FBP), 69.4% (ULD-AIDR 3D), and 77.8% (ULD-FIRST). Statistical analysis showed that the sensitivities of ULD-AIDR 3D and ULD-FIRST were significantly higher than that of ULD-FBP (P < .001). The performance of CAD software in ULD-CT was improved by using IR algorithms. In particular, the performance of CAD in ULD-FIRST was almost equivalent to that in LD-FBP. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Modified Framingham Risk Factor Score for Systemic Lupus Erythematosus.
Urowitz, Murray B; Ibañez, Dominique; Su, Jiandong; Gladman, Dafna D
2016-05-01
The traditional Framingham Risk Factor Score (FRS) underestimates the risk for coronary artery disease (CAD) in patients with systemic lupus erythematosus (SLE). We aimed to determine whether an adjustment to the FRS would more accurately reflect the higher prevalence of CAD among patients with SLE. Patients with SLE without a previous history of CAD or diabetes followed regularly at the University of Toronto Lupus Clinic were included. A modified FRS (mFRS) was calculated by multiplying the items by 1.5, 2, 3, or 4. In the first part of the study, using one-third of all eligible patients, we evaluated the sensitivity and specificity of the FRS and the different multipliers for the mFRS. In the second part of the study, using the remaining 2/3 of the eligible patients, we compared the predictive ability of the FRS to the mFRS. In the third part of the study, we assessed the prediction for CAD in a time-dependent analysis of the FRS and mFRS. There were 905 women (89.3%) with a total of 95 CAD events included. In part 1, we determined that a multiplier of 2 provided the best combination of sensitivity and specificity. In part 2, 2.4% of the patients were classified as moderate/high risk based on the classic FRS and 17.3% using the 2FRS (the FRS with a multiplier of 2). In part 3, a time-dependent covariate analysis for the prediction of the first CAD event revealed an HR of 3.22 (p = 0.07) for the classic FRS and 4.37 (p < 0.0001) for the 2FRS. An mFRS in which each item is multiplied by 2 more accurately predicts CAD in patients with SLE.
Jung, Eunice; Schnipper, Jeffrey L; Li, Qi; Linder, Jeffrey A; Rose, Alan F; Li, Ruzhuo; Eskin, Michael S; Housman, Dan; Middleton, Blackford; Einbinder, Jonathan S
2007-10-11
Quality reporting tools, integrated with ambulatory electronic health records (EHRs), may help clinicians understand performance, manage populations, and improve quality. The Coronary Artery Disease Quality Dash board (CAD QD) is a secure web report for performance measurement of a chronic care condition delivered through a central data warehouse and custom-built reporting tool. Pilot evaluation of the CAD Quality Dash board indicates that clinicians prefer a quality report that combines not only structured data from EHRs but one that facilitates actions to be taken on individual patients or on a population, i.e., for case management.
Surgical Nondestructive Evaluation (SuNDE)
2011-07-01
Primary selected A-10 wing inspection area, on the stringer runouts opposite the front spar access hole...at Stringer Doubler Runout . .........................................11 Figure 6. A-10 Inspection Required Under Stringer Flange...volume. ................................................14 Figure 9. CAD view of the A10 cavity showing the inspection areas on the stringer runouts
Milan, Raymond; Vasiliadis, Helen-Maria; Gontijo Guerra, Samantha; Berbiche, Djamal
2017-01-01
To evaluate the effect of patient out-of-pocket costs on adherence to antihypertensive agents (AHA) in community-dwelling older adults covered by the public drug insurance plan in Quebec. This is a secondary analysis of data from the "Étude sur la santé des aînés" study (2005-2008) on community-dwelling older adults in Quebec aged 65 years and older (N=2,811). The final sample included 881 participants diagnosed with arterial hypertension and treated with AHA. Medication adherence was measured with the proportion of days covered over a 2-year follow-up period (<80% and ≥80%). Out-of-pocket costs for AHA, in Canadian dollars (CAD), at cohort entry were categorized as follows: $0, $0.01-$5.00, $5.01-$10.00, $10.01-$15.00 and $15.01-$36.00. Multivariable logistic regression models were constructed to study adherence to AHA as a function of out-of-pocket costs while controlling for several confounders. Models were also stratified by annual household income (<$15,000 CAD and ≥$15,000 CAD). In this study, 80.8% of participants were adherent to their AHA. Among participants reporting an annual household income <$15,000 CAD, those with an out-of-pocket cost of $10.01-$15.00 CAD were significantly less adherent to their AHA than those with no contribution (OR =0.175, 95% CI: 0.042-0.740). Among participants reporting an income of ≥$15,000 CAD, those with out-of-pocket costs of $0.01-$5.00 CAD (OR =0.194; 95% CI: 0.048-0.787), $5.01-$10.00 CAD (OR =0.146; 95% CI: 0.036-0.589), $10.01-$15.00 CAD (OR =0.192; 95% CI: 0.047-0.777) and $15.01-$36.00 CAD (OR =0.160, 95% CI: 0.039-0.655) were significantly less adherent to their AHA than participants with no contribution. Increased out-of-pocket costs are associated with non-adherence to AHA in older adults covered by a public drug insurance plan, more importantly in those reporting an annual household income ≥$15,000 CAD. A reduction in the amount of out-of-pocket costs and yearly maximum contribution for drugs may improve adherence to treatment.
Hoseini, Fatemeh; Mahmazi, Sanaz; Mahmoodi, Khalil; Jafari, Gholam Ali; Soltanpour, Mohammad Soleiman
2018-03-01
Interleukin-18 (IL-18) is a proinflammatory and proatherogenic cytokine, and its genetic variations may contribute to the development of coronary artery disease (CAD). We sought to investigate the role of -137G/C polymorphism and gene expression levels of IL-18 in patients with CAD. The study population included 100 patients with angiographically proven CAD and 100 matched controls. Total RNA and DNA were extracted from leukocytes using appropriate kits. The genotype of -137G/C polymorphism and gene expression level of IL-18 was determined using allele-specific polymerase chain reaction (PCR) and real-time (RT)-PCR assay, respectively. The genotypic and allelic distribution of IL-18 -137G/C polymorphism was not significantly different between the two groups ( p > 0.050). Moreover, the -137G/C polymorphism did not increase the risk of CAD in dominant and recessive genetic models ( p > 0.050). However, subgroup analysis of CAD patients revealed that the IL-18 -137G/C polymorphism was significantly associated with increased risk of CAD in hypertensive patients (odds ratio (OR) = 7.51; 95% confidence interval (CI): 1.24-25.17; p = 0.019) and smokers (OR = 4.90; 95% CI: 1.21-19.70; p = 0.031) but not in the diabetic subpopulation ( p = 0.261). The genotype distribution of IL-18 -137G/C genetic polymorphism was significantly different among patients with one, two, and three stenotic vessels ( p < 0.050). The gene expression level of IL-18 was significantly higher in the CAD group than the control group ( p < 0.001). Moreover, the carriers of CC genotype had significantly lower gene expression levels of IL-18 than carriers of GG genotype ( p < 0.050). The -137G/C polymorphism of IL-18 may be associated with the CAD risk in hypertensive and smoker subgroup of CAD patients. The -137G/C polymorphism seems to play an important role in determining the severity of CAD. Increased IL-18 gene expression level is a significant risk factor for the development of CAD. The CC genotype of -137G/C polymorphism is associated with lower IL-18 gene expression levels.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Timothy Shaw; Anthony Baratta; Vaughn Whisker
2005-02-28
Task 4 report of 3 year DOE NERI-sponsored effort evaluating immersive virtual reality (CAVE) technology for design review, construction planning, and maintenance planning and training for next generation nuclear power plants. Program covers development of full-scale virtual mockups generated from 3D CAD data presented in a CAVE visualization facility. This report focuses on using Full-scale virtual mockups for nuclear power plant training applications.
Bagheri, Babak; Alikhani, Asal; Mokhtari, Hossein; Rasouli, Mehdi
2018-04-01
The hypothesis is proposed that the atherogenicity of lipoporotein fractions is correlated with the content of unesterified cholesterol. To evaluate the role and prognostic values of unesterified and esterified cholesterol in lipoprotein fractions for coronary artery disease (CAD). The study population consisted of 400 patients who were divided to CAD controls and cases according to the data of coronary angiography. Fractional cholesterol esterification (FCE) as well as the complete profile of lipids and (apo)lipoproteins were determined. Total cholesterol was increased significantly in CAD patients (196.3 ± 52.3 mg/dL vs. 185.7 ± 48.0, p≤ 0.049) and the increment occurred totally in unesterified portion (77.2 ± 28.4 mg/dL vs. 71.1 ± 24.4, p≤ 0.031). HDL cholesterol showed a significant decrease in CAD group (39.9 ± 9.5 mg/dL vs. 44.6 ± 10.5, p≤ 0.001), but the decrement occurred wholly in the esterified portion (26.2 ± 9.2 mg/dL vs. 31.1 ± 8.1, p≤ 0.001). NonHDL cholesterol was increased significantly in CAD group (156.8 ± 48.3 mg/dL vs. 140.3 ± 43.6, p≤ 0.001), and the changes occurred in both un- and esterified portions. FCE in HDL was diminished significantly in CAD patients (64.8 ± 13.9% vs. 69.3 ± 7.9, p≤ 0.01). In multivariate logistic regression analysis, unesterified cholesterol in NonHDL (UeNonHDLc) and esterified cholesterol in HDL (EsHDLc) excluded total cholesterol and HDLc respectively from the regression equation. In ROC analysis, the ratio of UeNonHDLc/EsHDLc was the strongest predictor for CAD among cholesterol subfractions. The results confirm that UeNonHDLc is atherogenic and EsHDLc is antiatherogenic and are independent risk factors for CAD.
Alqahtani, Fawaz
2017-01-01
Objective The purpose of this study was to determine the effect of two extraoral computer-aided design (CAD) and computer-aided manufacturing (CAM) systems, in comparison with conventional techniques, on the marginal fit of monolithic CAD/CAM lithium disilicate ceramic crowns. Study design This is an in vitro interventional study. Place and duration of study The study was carried out at the Department of Prosthodontics, School of Dentistry, Prince Sattam Bin Abdul-Aziz University, Saudi Arabia, from December 2015 to April 2016. Methodology A marginal gap of 60 lithium disilicate crowns was evaluated by scanning electron microscopy. In total, 20 pressable lithium disilicate (IPS e.max Press [Ivoclar Vivadent]) ceramic crowns were fabricated using the conventional lost-wax technique as a control group. The experimental all-ceramic crowns were produced based on a scan stone model and milled using two extraoral CAD/CAM systems: the Cerec group was fabricated using the Cerec CAD/CAM system, and the Trios group was fabricated using Trios CAD and milled using Wieland Zenotec CAM. One-way analysis of variance (ANOVA) and the Scheffe post hoc test were used for statistical comparison of the groups (α=0.05). Results The mean (±standard deviation) of the marginal gap of each group was as follows: the Control group was 91.15 (±15.35) µm, the Cerec group was 111.07 (±6.33) µm, and the Trios group was 60.17 (±11.09) µm. One-way ANOVA and the Scheffe post hoc test showed a statistically significant difference in the marginal gap between all groups. Conclusion It can be concluded from the current study that all-ceramic crowns, fabricated using the CAD/CAM system, show a marginal accuracy that is acceptable in clinical environments. The Trios CAD group displayed the smallest marginal gap. PMID:28352204
Yañez-Rivera, Teresa G; Baños-Gonzalez, Manuel A; Ble-Castillo, Jorge L; Torres-Hernandez, Manuel E; Torres-Lopez, Jorge E; Borrayo-Sanchez, Gabriela
2014-09-08
The amount of epicardial adipose tissue (EAT) around the heart has been identified as an independent predictor of coronary artery disease (CAD), potentially through local release of inflammatory cytokines. Ethnic differences have been observed, but no studies have investigated this relationship in the Mexican population. The objective of the present study was to evaluate whether a relationship exist between EAT thickness assessed via echocardiography with CAD and adiponectin levels in a Mexican population. We studied 153 consecutive patients who underwent coronary angiography and transthoracic echocardiography (TTE). EAT thickness on the free wall of the right ventricle was measured at the end of systole from parasternal long and short axis views of three consecutive cardiac cycles. Coronary angiograms were analyzed for the presence, extent and severity of CAD. Serum adiponectin, lipids, glucose, C-reactive protein and fibrinogen were determined. EAT thickness was greater in patients with CAD than in those without CAD from both parasternal long (5.39 ± 1.75 mm vs 4.00 ± 1.67 mm p<0.0001) and short-axis views (5.23 ± 1.67 vs 4.12 ± 1.77, p=0.001). EAT thickness measured from parasternal long and short-axis showed a statistically significant positive correlation with age (r=0.354, p<0.001; r=0.286, p<0.001 respectively), and waist circumference (r=0.189, p=0.019; r=0.217, p=0.007 respectively). A significant negative correlation between EAT thickness from the parasternal long axis with cholesterol-HDL was observed (r=-0.163, p=0.045). No significant correlation was found between epicardial fat thickness and serum adiponectin or with the severity of CAD. EAT thickness was greater in patients with CAD. However, no correlation was observed with the severity of the disease or with serum adiponectin levels. EAT thickness measured by echocardiography might provide additional information for risk assessment and prediction of CAD.
Schnatz, Peter F; Jiang, Xuezhi; Vila-Wright, Sharon; Aragaki, Aaron K; Nudy, Matthew; O'Sullivan, David M; Jackson, Rebecca; LeBlanc, Erin; Robinson, Jennifer G; Shikany, James M; Womack, Catherine R; Martin, Lisa W; Neuhouser, Marian L; Vitolins, Mara Z; Song, Yiqing; Kritchevsky, Stephen; Manson, JoAnn E
2014-08-01
The objective of this study was to evaluate whether increased serum 25-hydroxyvitamin D3 (25OHD3) concentrations, in response to calcium/vitamin D (CaD) supplementation, are associated with improved lipids in postmenopausal women. The parent trial was a double-blind, randomized, placebo-controlled, parallel-group trial designed to test the effects of CaD supplementation (1,000 mg of elemental calcium + 400 IU of vitamin D3 daily) versus placebo in postmenopausal women. Women from the general community, including multiple sites in the United States, were enrolled between 1993 and 1998. This cohort included 300 white, 200 African-American, and 100 Hispanic participants who were randomly selected from the Women's Health Initiative CaD trial. Serum 25OHD3 and lipid (fasting plasma triglycerides [TG], high-density lipoprotein cholesterol [HDL-C], and calculated low-density lipoprotein cholesterol [LDL-C]) levels were assessed before and after CaD randomization. There was a 38% increase in mean serum 25OHD3 concentrations after 2 years (95% CI, 1.29-1.47, P < 0.001) for women randomized to CaD (24.3 ng/mL postrandomization mean) compared with placebo (18.2 ng/mL). Women randomized to CaD had a 4.46-mg/dL mean decrease in LDL-C (P = 0.03). Higher concentrations of 25OHD3 were associated with higher HDL-C levels (P = 0.003), along with lower LDL-C and TG levels (P = 0.02 and P < 0.001, respectively). Supplemental CaD significantly increases 25OHD3 concentrations and decreases LDL-C. Women with higher 25OHD3 concentrations have more favorable lipid profiles, including increased HDL-C, lower LDL-C, and lower TG. These results support the hypothesis that higher concentrations of 25OHD3, in response to CaD supplementation, are associated with improved LDL-C.
Incorporation of composite defects from ultrasonic NDE into CAD and FE models
NASA Astrophysics Data System (ADS)
Bingol, Onur Rauf; Schiefelbein, Bryan; Grandin, Robert J.; Holland, Stephen D.; Krishnamurthy, Adarsh
2017-02-01
Fiber-reinforced composites are widely used in aerospace industry due to their combined properties of high strength and low weight. However, owing to their complex structure, it is difficult to assess the impact of manufacturing defects and service damage on their residual life. While, ultrasonic testing (UT) is the preferred NDE method to identify the presence of defects in composites, there are no reasonable ways to model the damage and evaluate the structural integrity of composites. We have developed an automated framework to incorporate flaws and known composite damage automatically into a finite element analysis (FEA) model of composites, ultimately aiding in accessing the residual life of composites and make informed decisions regarding repairs. The framework can be used to generate a layer-by-layer 3D structural CAD model of the composite laminates replicating their manufacturing process. Outlines of structural defects, such as delaminations, are automatically detected from UT of the laminate and are incorporated into the CAD model between the appropriate layers. In addition, the framework allows for direct structural analysis of the resulting 3D CAD models with defects by automatically applying the appropriate boundary conditions. In this paper, we show a working proof-of-concept for the composite model builder with capabilities of incorporating delaminations between laminate layers and automatically preparing the CAD model for structural analysis using a FEA software.
Variations in measured performance of CAD schemes due to database composition and scoring protocol
NASA Astrophysics Data System (ADS)
Nishikawa, Robert M.; Yarusso, Laura M.
1998-06-01
There is now a large effort towards developing computer- aided diagnosis (CAD) techniques. It is important to be able to compare performance of different approaches to be able to determine which ones are the most efficacious. There are currently a number of barriers preventing meaningful (statistical) comparisons, two of which are discussed in this paper: database composition and scoring protocol. We have examined how the choice of cases used to test a CAD scheme can affect its performance. We found that our computer scheme varied between a sensitivity of 100% to 77%, at a false-positive rate of 1.0 per image, with only 100% change in the composition of the database. To evaluate the performance of a CAD scheme the output of the computer must be graded. There are a number of different criteria that are being used by different investigators. We have found that for the same set of detection results, the measured sensitivity can be between 40 - 90% depending on the scoring methodology. Clearly consensus must be reached on these two issues in order for the field to make rapid progress. As it stands now, it is not possible to make meaningful comparisons of different techniques.
NASA Astrophysics Data System (ADS)
Melendez, Jaime; Sánchez, Clara I.; Philipsen, Rick H. H. M.; Maduskar, Pragnya; Dawson, Rodney; Theron, Grant; Dheda, Keertan; van Ginneken, Bram
2016-04-01
Lack of human resources and radiological interpretation expertise impair tuberculosis (TB) screening programmes in TB-endemic countries. Computer-aided detection (CAD) constitutes a viable alternative for chest radiograph (CXR) reading. However, no automated techniques that exploit the additional clinical information typically available during screening exist. To address this issue and optimally exploit this information, a machine learning-based combination framework is introduced. We have evaluated this framework on a database containing 392 patient records from suspected TB subjects prospectively recruited in Cape Town, South Africa. Each record comprised a CAD score, automatically computed from a CXR, and 12 clinical features. Comparisons with strategies relying on either CAD scores or clinical information alone were performed. Our results indicate that the combination framework outperforms the individual strategies in terms of the area under the receiving operating characteristic curve (0.84 versus 0.78 and 0.72), specificity at 95% sensitivity (49% versus 24% and 31%) and negative predictive value (98% versus 95% and 96%). Thus, it is believed that combining CAD and clinical information to estimate the risk of active disease is a promising tool for TB screening.
2017-01-01
Purpose Inflammatory rheumatic diseases (IRD) are associated with accelerated coronary artery disease (CAD), which may result from both systemic and vascular wall inflammation. There are indications that complement may be involved in the pathogenesis of CAD in Systemic Lupus Erythematosus (SLE) and Rheumatoid Arthritis (RA). This study aimed to evaluate the associations between circulating complement and complement activation products with mononuclear cell infiltrates (MCI, surrogate marker of vascular inflammation) in the aortic media and adventitia in IRDCAD and non-IRDCAD patients undergoing coronary artery bypass grafting (CABG). Furthermore, we compared complement activation product deposition patterns in rare aorta adventitial and medial biopsies from SLE, RA and non-IRD patients. Methods We examined plasma C3 (p-C3) and terminal complement complexes (p-TCC) in 28 IRDCAD (SLE = 3; RA = 25), 52 non-IRDCAD patients, and 32 IRDNo CAD (RA = 32) from the Feiring Heart Biopsy Study. Aortic biopsies taken from the CAD only patients during CABG were previously evaluated for adventitial MCIs. The rare aortic biopsies from 3 SLE, 3 RA and 3 non-IRDCAD were assessed for the presence of C3 and C3d using immunohistochemistry. Results IRDCAD patients had higher p-TCC than non-IRDCAD or IRDNo CAD patients (p<0.0001), but a similar p-C3 level (p = 0.42). Circulating C3 was associated with IRD duration (ρ, p-value: 0.46, 0.03). In multiple logistic regression analysis, IRD remained significantly related to the presence and size of MCI (p<0.05). C3 was present in all tissue samples. C3d was detected in the media of all patients and only in the adventitia of IRD patients (diffuse in all SLE and focal in one RA). Conclusion The independent association of IRD status with MCI and the observed C3d deposition supports the unique relationship between rheumatic disease, and, in particular, SLE with the complement system. Exaggerated systemic and vascular complement activation may accelerate CVD, serve as a CVD biomarker, and represent a target for new therapies. PMID:28362874
Agra, Rosa María; Teijeira-Fernández, Elvis; Pascual-Figal, Domingo; Jesús, Sánchez-Más; Fernández-Trasancos, Angel; Sierra, Juan; González-Juanatey, José Ramón; Eiras, Sonia
2014-04-01
S100A9 is a new inflammatory marker associated with obesity and cardiovascular disease. Because epicardial adipose tissue (EAT) is an inflammatory source in coronary artery disease (CAD), our aim was to evaluate the S100A9 levels in plasma and EAT and its association with CAD. Blood, EAT and/or subcutaneous adipose tissue (SAT) biopsies were obtained from 89 patients undergoing elective cardiac surgery. Plasma S100A9 and adiponectin were analyzed by enzyme-linked immunosorbent assay (ELISA) and mRNA expression in both fat pads and were measured by real-time polymerase chain reaction (PCR). Our results have shown higher levels of plasma S100A9 in patients with CAD than those without (29 [10-50] vs. 17 [3-28] ng/mL; p=0.007). They were dependent on the number of injured-coronaries (p=0.002) with tendency toward negative association with plasma adiponectin (p=0.139). Although EAT expressed higher levels than SAT and their levels were higher in CAD patients, this last difference did not reach statistical significance. However, there was a positive correlation between neutrophils and EAT S100A9 expression (p=0.007) that may reveal an increase of neutrophil filtration on this fat pad. Plasma S100A9 levels are increased in chronic CAD. The absence of differences regarding EAT S100A9 expression levels indicates a differential inflammatory process between fat tissues and blood in CAD process. Copyright © 2014 Elsevier Inc. All rights reserved.
Hwang, Hui-Jeong; Sohn, Il Suk; Kim, Dong-Hee; Park, Chang-Bum; Cho, Jin-Man; Kim, Chong-Jin
2017-08-15
Interarm blood pressure (BP) difference has been reported to be associated with atherosclerosis and increased cardiovascular death. We were to investigate associations of interarm systolic blood pressure (SBP) difference with heart rate recovery (HRR) after exercise, an index of autonomic function, and carotid atherosclerotic markers, and to evaluate the association of interarm SBP difference with concurrent coronary artery disease (CAD). A total of 995 consecutive patients who underwent treadmill stress echocardiography with chest pain but no history of CAD were enrolled. Interarm SBP difference, carotid intima-media thickness (IMT) and plaque were measured before exercise, and HRR 2min following exercise was assessed. Suspected CAD was defined as newly developed wall motion abnormalities after treadmill exercise. Patients with an interarm SBP difference≥10mmHg had higher prevalence of hypertension, increased right and left SBP, right diastolic BP, mean arterial pressure, body mass index and carotid IMT, existent carotid plaque, lower metabolic equivalents and slower HRR. Interarm SBP difference≥10mmHg was independently associated with slower HRR and existent carotid plaque. Suspected CAD was associated with existent carotid plaque or slower HRR, but not with an interarm SBP difference≥10mmHg. Increased interarm SBP difference was associated with lower autonomic modulation and carotid atherosclerosis in patients with chest pain and no history of CAD, but not with suspected CAD. Observed adverse prognosis in patients with increased interarm BP difference might result from long-term persistent autonomic dysfunction and atherosclerosis. Copyright © 2017 Elsevier B.V. All rights reserved.
Qian, Juying; Chen, Zhangwei; Ge, Junbo; Ma, Jianying; Chang, Shufu; Fan, Bing; Liu, Xuebo; Ge, Lei
2010-07-01
Aortic valve calcification (AVC), which has been confirmed to be associated with various risk factors of cardiac disease, is common in the elderly and associated with increased cardiovascular mortality. It has been hypothesized that AVC is associated with coronary atherosclerotic disease, and its severity. Between July 2007 and November 2007, a total of 235 patients with chest pain or chest distress were admitted to the authors' institution for coronary angiography. The severity of coronary atherosclerotic disease (CAD) was evaluated by the Gensini score, the number of stenosed vessels, and the prevalence of total occlusion. All patients underwent transthoracic echocardiography to detect AVC. Patients with CAD had a higher prevalence of AVC than those without CAD (44% versus 26%, p = 0.005). Likewise, the prevalence of AVC was significantly higher in patients with a higher Gensini score than in those with a lower score. Patients with AVC had a higher prevalence of CAD, and higher Gensini scores and numbers of stenosed coronary arteries, even after stratification by age (65 years). On multivariable logistic regression analysis for CAD, the odds ratio (OR) of AVC was 2.315 (95% confidence interval (CI): 1.158-4.629, p = 0.018); this value was higher than that for total cholesterol (OR = 1.637, p = 0.008), lipoprotein-a (OR = 1.003, p = 0.015) and fibrinogen (OR = 1.009, p = 0.006), and marginally less than that for male gender (OR = 2.665, p = 0.005). Patients with AVC had a higher prevalence and greater severity of CAD.
NASA Astrophysics Data System (ADS)
Tsehay, Yohannes K.; Lay, Nathan S.; Roth, Holger R.; Wang, Xiaosong; Kwak, Jin Tae; Turkbey, Baris I.; Pinto, Peter A.; Wood, Brad J.; Summers, Ronald M.
2017-03-01
Prostate cancer (PCa) is the second most common cause of cancer related deaths in men. Multiparametric MRI (mpMRI) is the most accurate imaging method for PCa detection; however, it requires the expertise of experienced radiologists leading to inconsistency across readers of varying experience. To increase inter-reader agreement and sensitivity, we developed a computer-aided detection (CAD) system that can automatically detect lesions on mpMRI that readers can use as a reference. We investigated a convolutional neural network based deep-learing (DCNN) architecture to find an improved solution for PCa detection on mpMRI. We adopted a network architecture from a state-of-the-art edge detector that takes an image as an input and produces an image probability map. Two-fold cross validation along with a receiver operating characteristic (ROC) analysis and free-response ROC (FROC) were used to determine our deep-learning based prostate-CAD's (CADDL) performance. The efficacy was compared to an existing prostate CAD system that is based on hand-crafted features, which was evaluated on the same test-set. CADDL had an 86% detection rate at 20% false-positive rate while the top-down learning CAD had 80% detection rate at the same false-positive rate, which translated to 94% and 85% detection rate at 10 false-positives per patient on the FROC. A CNN based CAD is able to detect cancerous lesions on mpMRI of the prostate with results comparable to an existing prostate-CAD showing potential for further development.
The effect of glazing and aging on the surface properties of CAD/CAM resin blocks
Tuncer, Safa; Kara, Dilan; Demirci, Mustafa
2018-01-01
PURPOSE To investigate the effect of accelerated aging on surface properties of glazed CAD/CAM resin blocks using a 2D surface profilometer and a 3D non-contact optical profilometer. MATERIALS AND METHODS Three types of CAD/CAM resin restorative materials, LAVA Ultimate (3M ESPE, St Paul, MN, USA), VITA Enamic (Vita Zahnfabrik H. Rauter, Bad Säckingen, Germany), and Cerasmart (GC Corparation, Tokyo, Japan) were used for this study. CAD/CAM blocks were cut in 3-mm thickness slabs and divided into three groups; Group 1: control group (specimens polished with 600 grit SCI paper); Group 2: specimens sandblasted, silanized, and glazed with Optiglaze Color (GC); Group 3: glazed specimens subjected to 5000 thermocycles (n=15). The surface roughness (Ra and Rz) was evaluated using a profilometer and a 3D scanning instrument. Data were analyzed using two-way ANOVA and Tukey's post-hoc test (P<.05). RESULTS LAVA, VITA, and Cerasmart exhibited statistically similar Ra and Rz values for each group (P>.05). For VITA and Cerasmart, the specimens in Group 1 exhibited significantly higher Ra values than Group 2 (P<.05). Group 1 (0.502 Ra), Group 2 (0.384 Ra), and Group 3 (0.431 Ra) exhibited statistically similar Ra values for LAVA (P=.062). After 5000 thermocycles, surface roughness values did not change significantly for glazed LAVA, VITA, and Cerasmart (P>.05). CONCLUSION Glaze material Optiglaze Color makes CAD/CAM resin surfaces smooth and glazed CAD/CAM surfaces seem resistant to deterioration under 5000 thermocycles. PMID:29503714
The effect of glazing and aging on the surface properties of CAD/CAM resin blocks.
Tekçe, Neslihan; Fidan, Sinan; Tuncer, Safa; Kara, Dilan; Demirci, Mustafa
2018-02-01
To investigate the effect of accelerated aging on surface properties of glazed CAD/CAM resin blocks using a 2D surface profilometer and a 3D non-contact optical profilometer. Three types of CAD/CAM resin restorative materials, LAVA Ultimate (3M ESPE, St Paul, MN, USA), VITA Enamic (Vita Zahnfabrik H. Rauter, Bad Säckingen, Germany), and Cerasmart (GC Corparation, Tokyo, Japan) were used for this study. CAD/CAM blocks were cut in 3-mm thickness slabs and divided into three groups; Group 1: control group (specimens polished with 600 grit SCI paper); Group 2: specimens sandblasted, silanized, and glazed with Optiglaze Color (GC); Group 3: glazed specimens subjected to 5000 thermocycles (n=15). The surface roughness (R a and R z ) was evaluated using a profilometer and a 3D scanning instrument. Data were analyzed using two-way ANOVA and Tukey's post-hoc test ( P <.05). LAVA, VITA, and Cerasmart exhibited statistically similar R a and R z values for each group ( P >.05). For VITA and Cerasmart, the specimens in Group 1 exhibited significantly higher R a values than Group 2 ( P <.05). Group 1 (0.502 R a ), Group 2 (0.384 R a ), and Group 3 (0.431 R a ) exhibited statistically similar R a values for LAVA ( P =.062). After 5000 thermocycles, surface roughness values did not change significantly for glazed LAVA, VITA, and Cerasmart ( P >.05). Glaze material Optiglaze Color makes CAD/CAM resin surfaces smooth and glazed CAD/CAM surfaces seem resistant to deterioration under 5000 thermocycles.
Granica, Sebastian; Piwowarski, Jakub P; Kiss, Anna K
2014-01-01
Lythri salicariaeherba is a pharmacopoeial plant material used by patients in the form of infusions in the treatment of acute diarrhoea. According to its pharmacopoeial monograph it is standardised for total tannin content, which should be not less than 5.0% using pyrogallol as a standard. Previous studies have shown that aqueous extracts from Lythri herba contain mainly ellagitannins among which vescalagin, castalagin and salicarinins A and B are dominating constituents. To develop and validate an efficient UHPLC coupled with a charged aerosol detector (CAD) method for quantification of four major ellagitannins in Lythri salicariaeherba and in one commercial preparation. Extraction conditions of ellagitannins from plant material were optimised. The relative response factors for vescalagin, castalagin and salicarinins A and B using gallic acid as an external standard were determined for the CAD detector. Then, a UHPLC method for quantification of ellagitannins was developed and validated. Four major ellagitannins were quantified in four samples of Lythri herba and in one commercial preparation. The sum of ellagitannins for each sample was determined, which varied from 30.66 to 48.80 mg/g of raw material and 16.57 mg per capsule for the preparation investigated. The first validated UHPLC/CAD UHPLC-CAD method for quantification of four major ellagitannins was developed. The universality of the CAD response was evaluated and it is shown that although all compounds analysed have similar structures their CAD response differs significantly. Copyright © 2013 John Wiley & Sons, Ltd.
Abu-Amero, Khaled K; Al-Boudari, Olayan M; Mohamed, Gamal H; Dzimiri, Nduna
2006-01-01
Background The role of the Beta2-adrenoceptor (beta2-AR) Gln27Glu polymorphism in the manifestation of cardiovascular diseases is still unclear. Methods In the present study, we evaluated the potential relevance of the c.79 C>G (p.Gln27Glu) polymorphism of this receptor gene for coronary artery disease (CAD) and its associated risk factors in Saudi Arabs. Genotyping was performed by PCR using the confronting two-pair primer (PCR-CTPP) method. Results In the general population group (BD) (n = 895), 68.5% were homozygous wild-type C/C, 28.3% were heterozygous C/G and 3.2% were homozygous mutant G/G. Among the CAD patients (n = 773), 50.6% were homozygous wild-type C/C, 43.6% were heterozygous C/G and 5.8% were homozygous mutant G/G, while in the angiographed control group (CON) (n = 528), 71.8% were C/C, 24.4% C/G and 3.8% G/G genotypes. These results indicate that both the C/G (p = < .001) and G/G (p = .005) genotypes are significantly associated with CAD, when compared to the CON group. In addition, C/G (p = < .001) and G/G (p = < .001) were significantly associated with CAD, when compared to the BD group. Furthermore, stepwise logistic regression showed that the genotype [C/G (p < .001) and G/G (p < .001)] increase the risk of CAD. Conclusion These results shows that the Gln27Glu genotypes (homo- or heterozygous) of the beta2-AR may be independent predictors of severe CAD. PMID:16573811
Association of serum omentin-1 levels with coronary artery disease
Zhong, Xia; Zhang, Hai-yang; Tan, Hui; Zhou, Yi; Liu, Fu-li; Chen, Fu-qin; Shang, De-ya
2011-01-01
Aim: Omentin-1, a novel adipokine expressed in visceral adipose tissue, is negatively correlated with insulin resistance and obesity. Decreased omentin-1 expression has been found in many chronic inflammatory diseases. However, the role of omentin-1 in coronary artery disease (CAD) has not been elucidated. The aim of the present study was to determine whether serum concentration of omentin-1 was independently associated with CAD. Methods: One hundred and fifty five patients with CAD were divided into two groups: acute coronary syndrome (ACS) and stable angina pectoris (SAP). A total of 52 healthy participants served as controls. Serum concentrations of omentin-1 and interleukin-6 (IL-6) were measured using ELISA. The association of omentin-1 with CAD and cardiovascular disease risk factors was evaluated. Results: Serum omentin-1 levels were lower in patients with ACS or SAP compared with controls (ACS, 113.08±61.43 ng/mL; SAP, 155.41±66.89 ng/mL; control, 254.00±72.9 ng/mL; P<0.01). Patients with ACS also had lower serum concentrations of omentin-1 compared with patients with SAP (P<0.01). Serum concentration of omentin-1 was negatively correlated with body mass index (r=−0.17, P<0.05) and serum IL-6 concentration (r=−0.19, P<0.05). Furthermore, multiple logistic regression analysis showed that serum omentin-1 concentrations were independently correlated with CAD. Conclusion: The findings suggest that serum concentrations of omentin-1 are related to CAD. PMID:21602837
Planer, David; Smits, Pieter C; Kereiakes, Dean J; Kedhi, Elvin; Fahy, Martin; Xu, Ke; Serruys, Patrick W; Stone, Gregg W
2011-10-01
This study sought to compare the clinical outcomes of everolimus-eluting stents (EES) versus paclitaxel-eluting stents (PES) in patients with acute coronary syndromes (ACS) and stable coronary artery disease (CAD). Although randomized trials have shown superiority of EES to PES, the safety and efficacy of EES in ACS is unknown. We performed a patient-level pooled analysis from the prospective, randomized SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) II, III, IV, and COMPARE (A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice) trials in which 2,381 patients with ACS and 4,404 patients with stable CAD were randomized to EES or to PES. Kaplan-Meier estimates of death, myocardial infarction (MI), ischemia-driven target lesion revascularization, and stent thrombosis were assessed at 2 years and stratified by clinical presentation (ACS vs. stable CAD). At 2 years, patients with ACS compared with stable CAD had higher rates of death (3.2% vs. 2.4%, hazard ratio [HR]: 1.37 [95% confidence interval (CI): 1.02 to 1.85], p = 0.04) and MI (4.9% vs. 3.4%, HR: 1.45 [95% CI: 1.14 to 1.85], p = 0.02). In patients with ACS, EES versus PES reduced the rate of death or MI (6.6% vs. 9.3%, HR: 0.70 [95% CI: 0.52 to 0.94], p = 0.02), stent thrombosis (0.7% vs. 2.9%, HR: 0.25 [95% CI: 0.12 to 0.52], p = 0.0002), and ischemia-driven target lesion revascularization (4.7% vs. 6.2%, HR: 0.69 [95% CI: 0.48 to 0.99], p = 0.04). In patients with stable CAD, EES reduced the rate of death or MI (4.5% vs. 7.1%, HR: 0.62 [95% CI: 0.48 to 0.80], p = 0.0002), stent thrombosis (0.7% vs. 1.8%, HR: 0.34 [95% CI: 0.19 to 0.62], p = 0.0002), and ischemia-driven target lesion revascularization (3.9% vs. 6.9%, HR: 0.55 [95% CI: 0.42 to 0.73], p < 0.0001). Treatment with EES versus PES provides enhanced safety and efficacy regardless of the acuity of the clinical syndrome being treated and appears to mitigate the increased risk of stent thrombosis associated with ACS. (A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Patients With de Novo Native Coronary Artery Lesions [SPIRIT II]; NCT00180310; SPIRIT III: A Clinical Evaluation of the Investigational Device XIENCE V Everolimus Eluting Coronary Stent System [EECSS] in the Treatment of Subjects With de Novo Native Coronary Artery Lesions [SPIRIT III]; NCT00180479; SPIRIT IV Clinical Trial: Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Subjects With de Novo Native Coronary Artery Lesions [SPIRIT IV]; NCT00307047; A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice: the COMPARE Trial [COMPARE]; NCT01016041). Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Al-Dwairi, Ziad N; Tahboub, Kawkab Y; Baba, Nadim Z; Goodacre, Charles J
2018-06-13
The introduction of computer-aided design/computer-aided manufacturing (CAD/CAM) technology to the field of removable prosthodontics has recently made it possible to fabricate complete dentures of prepolymerized polymethyl methacrylate (PMMA) blocks, which are claimed to be of better mechanical properties; however, no published reports that have evaluated mechanical properties of CAD/CAM PMMA. The purpose of this study was to compare flexural strength, impact strength, and flexural modulus of two brands of CAD/CAM PMMA and a conventional heat-cured PMMA. 45 rectangular specimens (65 mm × 10 mm × 3 mm) were fabricated (15 CAD/CAM AvaDent PMMA specimens from AvaDent, 15 CAD/CAM Tizian PMMA specimens from Shütz Dental, 15 conventional Meliodent PMMA specimens from Heraeus Kulzer) and stored in distilled water at (37 ± 1°C) for 7 days. Specimens (N = 15) in each group were subjected to the three-point bending test and impact strength test, employing the Charpy configuration on unnotched specimens. The morphology of the fractured specimens was studied under a scanning electron microscope (SEM). Statistical analysis was performed using one-way ANOVA and Tukey pairwise multiple comparisons with 95% confidence interval. The Schütz Dental specimens showed the highest mean flexural strength (130.67 MPa) and impact strength (29.56 kg/m 2 ). The highest mean flexural modulus was recorded in the AvaDent group (2519.6 MPa). The conventional heat-cured group showed the lowest mean flexural strength (93.33 MPa), impact strength (14.756 kg/m 2 ), and flexural modulus (2117.2 MPa). Differences in means of flexural properties between AvaDent and Schütz Dental specimens were not statistically significant (p > 0.05). As CAD/CAM PMMA specimens exhibited improved flexural strength, flexural modulus, and impact strength in comparison to the conventional heat-cured groups, CAD/CAM dentures are expected to be more durable. Different brands of CAD/CAM PMMA may have inherent variations in mechanical properties. © 2018 by the American College of Prosthodontists.
Sharma, R; Mahajan, M; Singh, B; Singh, G; Singh, P
2011-12-01
High concentration of apolipoprotein B (apoB) is a risk factor for coronary artery disease (CAD). The association of the APOB gene polymorphism c.12669G>A, p.Gln4154Lys with the risk of CAD varies considerably in different populations. The present study represents the first investigation regarding the role of this APOB gene polymorphism with CAD in the Indian Punjabi population. We have studied the APOB gene polymorphism c.12669G>A, p.Gln4154Lys and its relationship with lipid, apoB, low-density lipoprotein (LDL) heterogeneity and oxidation in subjects suffering from CAD. The study was conducted on 87 patients with CAD; 75 healthy subjects served as controls. Polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) was used to determine the DNA polymorphism in the APOB gene. Frequency of R- (mutant) allele was significantly high (p <0.05) in CAD patients when compared to controls. Variations in serum lipid levels in the R+R+ and R+R- APOB genotypes were insignificant (p >0.05). However, serum apoB levels were significantly raised (p <0.05) in CAD patients with the R+R- genotype as compared to those with the R+R+ APOB genotype. Coronary artery disease patients had raised significantly raised (p <0.01) Log triglyceride/high density lipoprotein-cholesterol (HDL-C) ratio, apoB carbonyl content and increased malondialdehyde-low density lipoprotein (MDA-LDL levels, irrespective of APOB genotype as compared to controls. Carriers of the R- allele are at higher risk of CAD, probably because of elevated serum apoB levels in the Indian Punjabi population. Overall, it may be concluded that the R- allele might be associated with increased susceptibility towards CAD development in the Indian Punjabi population, and one of the linking factor is the elevation in serum apoB levels. However, this association needs further evaluation in a larger population. Secondly, the robust mechanism behind the positive association of the R- allele with raised serum apoB levels needs to be explored, which might be helpful in the strengthening the observed results.
Zhang, Huifeng; Dong, Pingshuan; Yang, Xuming; Liu, Zhenghao
2014-01-01
Background: The aim of the current study was to evaluate the association of PAI-1 4G/5G polymorphism with coronary artery disease (CAD) risk using a meta-analysis. Methods: All eligible studies were identified through a search of PubMed, EMBASE, China National Knowledge Infrastructure (CNKI), Database of Chinese Scientific and Technical Periodicals, and China Biology Medical literature database (CBM) before June 2014. The association between the PAI-1 4G/5G polymorphism and CAD risk was estimated by odds ratio (OR) and 95% confidence interval (CI). Results: A total of 72 studies including 23557 cases and 21526 controls were eventually collected. The PAI-1 4G/5G polymorphism was significant associated with CAD risk in overall population (OR=1.19, 95% CI 1.10-1.28, P < 0.00001). The combination of adjusted ORs for CAD was 1.20 (95% CI 1.03-1.40, P=0.02). This polymorphism was associated with CAD risk in Caucasians (OR=1.10, 95% CI 1.02-1.19, P=0.01) and Asians (OR=1.46, 95% CI 1.21-1.75, P < 0.0001). This polymorphism significantly increased MI risk (OR=1.15, 95% CI 1.06-1.25, P=0.001). In the subgroup analysis by age, this polymorphism was significantly associated with early-onset CAD risk (OR=1.21, 95% CI 1.02-1.43, P=0.03). In the gender subgroup analyses, a statistically significant association was found in male CAD patients (OR=1.10, 95% CI 1.01-1.20, P=0.04). Both T2DM patients and non-T2DM patients carrying 4G allele showed increased CAD risks (OR=2.23, 95% CI 1.27-3.92, P=0.005 and OR=1.64, 95% CI 1.19-2.25, P=0.002, respectively). Conclusions: This meta-analysis suggested that PAI-1 4G/5G polymorphism was a risk factor for CAD. PMID:25419432
2014-01-01
Background In recent decades cultivation of flax and its application have dramatically decreased. One of the reasons for this is unpredictable quality and properties of flax fibre, because they depend on environmental factors, retting duration and growing conditions. These factors have contribution to the fibre composition, which consists of cellulose, hemicelluloses, lignin and pectin. By far, it is largely established that in flax, lignin reduces an accessibility of enzymes either to pectin, hemicelluloses or cellulose (during retting or in biofuel synthesis and paper production). Therefore, in this study we evaluated composition and properties of flax fibre from plants with silenced CAD (cinnamyl alcohol dehydrogenase) gene, which is key in the lignin biosynthesis. There is evidence that CAD is a useful tool to improve lignin digestibility and/or to lower the lignin levels in plants. Results Two studied lines responded differentially to the introduced modification due to the efficiency of the CAD silencing. Phylogenetic analysis revealed that flax CAD belongs to the “bona-fide” CAD family. CAD down-regulation had an effect in the reduced lignin amount in the flax fibre cell wall and as FT-IR results suggests, disturbed lignin composition and structure. Moreover introduced modification activated a compensatory mechanism which was manifested in the accumulation of cellulose and/or pectin. These changes had putative correlation with observed improved fiber’s tensile strength. Moreover, CAD down-regulation did not disturb at all or has only slight effect on flax plants’ development in vivo, however, the resistance against flax major pathogen Fusarium oxysporum decreased slightly. The modification positively affected fibre possessing; it resulted in more uniform retting. Conclusion The major finding of our paper is that the modification targeted directly to block lignin synthesis caused not only reduced lignin level in fibre, but also affected amount and organization of cellulose and pectin. However, to conclude that all observed changes are trustworthy and correlated exclusively to CAD repression, further analysis of the modified plants genome is necessary. Secondly, this is one of the first studies on the crop from the low-lignin plants from the field trail which demonstrates that such plants could be successfully cultivated in a field. PMID:24552628
Two-year evaluation indicates zirconia bridges acceptable alternative to PFMs.
Perry, Ronald D; Kugel, Gerard; Sharma, Shradha; Ferreira, Susana; Magnuson, Britta
2012-01-01
The aim of this in-vivo study was to evaluate the 2-year clinical performance of zirconia computer-aided design/computer-aided manufacturing (CAD/CAM)-generated bridges. A total of 16 three- or four-unit Lava zirconia bridges were done on 15 subjects. The bridges were cemented using RelyX™ Unicem Self-Adhesive Universal Resin Cement. Evaluation was done at 6-month, 1-year, and 2-year recall visits. Evaluation criteria were color stability and matching, marginal integrity, marginal discoloration, incidence of caries, changes in restoration-tooth interface, changes in surface texture, postoperative sensitivity, maintenance of periodontal health, changes in proximal and opposing teeth, and maintenance of anatomic form. In each of these parameters, the bridges were rated in one of three possible categories: "A" (alpha)--ideal; "B" (bravo)--acceptable; and "C" (charlie)--unacceptable. After 2 years, 100% of the bridges were rated "A" for color stability and matching, marginal discoloration, incidence of caries, changes in restoration-tooth interface, changes in surface texture, postoperative sensitivity, and change in proximal or opposing teeth. In the parameter of marginal integrity, 6.25% of the bridges were rated "B;" the remaining 93.75% were rated "A." Maintenance of periodontal health was rated "B" for 6.25% of the bridges and "A" for 93.75%. At 2 years, 12.5% of the bridges rated "C" in maintenance of anatomic form and 87.5% rated "A." The overall clinical outcome was that the CAD/CAM-generated zirconia bridges were clinically acceptable.
Implementation and consistency of Heart Team decision-making in complex coronary revascularisation.
Pavlidis, Antonis N; Perera, Divaka; Karamasis, Grigoris V; Bapat, Vinayak; Young, Chris; Clapp, Brian R; Blauth, Chris; Roxburgh, James; Thomas, Martyn R; Redwood, Simon R
2016-03-01
A multidisciplinary team (MDT) approach for decision-making in patients with complex coronary artery disease (CAD) is now a class IC recommendation in the European and American guidelines for myocardial revascularisation. The aim of this study was to evaluate the implementation and consistency of Heart Team HT decision-making in complex coronary revascularisation. We prospectively evaluated the data of 399 patients derived from 51 consecutive MDT meetings held in a tertiary cardiac centre. A subset of cases was randomly selected and re-presented with the same clinical data to a panel blinded to the initial outcome, at least 6 months after the initial discussion, in order to evaluate the reproducibility of decision-making. The most common decisions included continued medical management (30%), coronary artery bypass grafting (CABG) (26%) and percutaneous coronary intervention (PCI) (17%). Other decisions, such as further assessment of symptoms or evaluation with further invasive or non-invasive tests were made in 25% of the cases. Decisions were implemented in 93% of the cases. On re-discussion of the same data (n=40) within a median period of 9 months 80% of the initial HT recommendations were successfully reproduced. The Heart Team is a robust process in the management of patient with complex CAD and decisions are largely reproducible. Although outcomes are successfully implemented in the majority of the cases, it is important that all clinical information is available during discussion and patient preference is taken into account. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Nozue, Tsuyoshi; Fukui, Kazuki; Koyama, Yutaka; Fujii, Hiroyuki; Kunishima, Tomoyuki; Hikita, Hiroyuki; Hibi, Kiyoshi; Miyazawa, Akiyoshi; Michishita, Ichiro
2016-05-01
Patients with diabetes mellitus are at high risk for developing coronary artery disease (CAD), even if they are treated with statins. Several studies have shown the beneficial effects of dipeptidyl peptidase-4 (DPP-4) inhibitors on the cardiovascular system in an animal model. However, recent clinical trials using DPP-4 inhibitors have shown that these inhibitors fail to reduce the occurrence of cardiovascular events. Therefore, this study will be performed to evaluate the effects of sitagliptin, a DPP-4 inhibitor, on coronary atherosclerosis in patients with type 2 diabetes. This study will be a prospective, open-label, randomized multicenter trial performed in 6 centers in Japan. Stable CAD patients with type 2 diabetes who have undergone successful percutaneous coronary intervention under integrated backscatter (IB)-intravascular ultrasound (IVUS) guidance will be studied. They will be randomly assigned to either the sitagliptin group or a control group. After 48 weeks' treatment, the IVUS examination will be repeated in the same coronary artery as at baseline. The primary end point will be the percentage change in plaque volume measured using grayscale IVUS from baseline to the 48-week follow-up. This study will be the first multicenter trial to evaluate the effects of a DPP-4 inhibitor on coronary atherosclerosis evaluated using IB-IVUS, and the findings will clarify the anti-atherogenic effects of sitagliptin.
Okamoto, Takumi; Koide, Tetsushi; Sugi, Koki; Shimizu, Tatsuya; Anh-Tuan Hoang; Tamaki, Toru; Raytchev, Bisser; Kaneda, Kazufumi; Kominami, Yoko; Yoshida, Shigeto; Mieno, Hiroshi; Tanaka, Shinji
2015-08-01
With the increase of colorectal cancer patients in recent years, the needs of quantitative evaluation of colorectal cancer are increased, and the computer-aided diagnosis (CAD) system which supports doctor's diagnosis is essential. In this paper, a hardware design of type identification module in CAD system for colorectal endoscopic images with narrow band imaging (NBI) magnification is proposed for real-time processing of full high definition image (1920 × 1080 pixel). A pyramid style image segmentation with SVMs for multi-size scan windows, which can be implemented on an FPGA with small circuit area and achieve high accuracy, is proposed for actual complex colorectal endoscopic images.
NASA Astrophysics Data System (ADS)
Szeleszczuk, Łukasz; Pisklak, Dariusz Maciej; Zielińska-Pisklak, Monika; Wawer, Iwona
2016-06-01
In this article we report the results of combined theoretical and experimental structural studies on cinnamic acid derivatives (CADs), one of the main groups of secondary metabolites present in various medicinal plant species and food products of plant origin. The effects of structural differences in CADs on their spectroscopic properties were studied in detail by both: solid-state NMR and GIAO/GIPAW calculations. Theoretical computations were used in order to perform signal assignment in 13C CP/MAS NMR spectra of the cinnamic, o-coumaric, m-coumaric, p-coumaric, caffeic, ferulic, sinapic and 3,4-dimethoxycinnamic acids, and to evaluate the accuracy of GIPAW and GIAO methodology.
Novel CAD/CAM rapid prototyping of next-generation biomedical devices
NASA Astrophysics Data System (ADS)
Doraiswamy, Anand
An aging population with growing healthcare needs demands multifaceted tools for diagnosis and treatment of health conditions. In the near-future, drug-administration devices, implantable devices/sensors, enhanced prosthesis, artificial and unique functional tissue constructs will become increasingly significant. Conventional technologies for mass-produced implants do not adequately take individual patient anatomy into consideration. Development of novel CAD/CAM rapid prototyping techniques may significantly accelerate progress of these devices for next-generation patient-care. In this dissertation, several novel rapid prototyping techniques have been introduced for next-generation biomedical applications. Two-photon polymerization was developed to microfabricate scaffolds for tissue engineering, microneedles for drug-delivery and ossicular replacement prostheses. Various photoplymers were evaluated for feasibility, mechanical properties, cytotoxicity, and surface properties. Laser direct write using MDW was utilized for developing microstructures of bioceramics such as hydroxyapatite, and viable mammalian osteosarcoma cells. CAD/CAM laser micromachining (CLM) was developed to engineer biointerfaces as surface recognition regions for differential adherence of cells and growth into tissue-like networks. CLM was also developed for engineering multi-cellular vascular networks. Cytotoxic evaluations and growth studies demonstrated VEGF-induced proliferation of HAAE-1 human aortic endothelial cells with inhibition of HA-VSMC human aortic smooth muscle cells. Finally, piiezoelectric inkjet printing was developed for controlled administration of natural and synthetic adhesives to overcome several problems associated with conventional tissue bonding materials, and greatly improve wound-repair in next generation eye repair, fracture fixation, organ fixation, wound closure, tissue engineering, and drug delivery devices.
Automated melanoma recognition in dermoscopic images based on extreme learning machine (ELM)
NASA Astrophysics Data System (ADS)
Rahman, Md. Mahmudur; Alpaslan, Nuh
2017-03-01
Melanoma is considered a major health problem since it is the deadliest form of skin cancer. The early diagnosis through periodic screening with dermoscopic images can significantly improve the survival rate as well as reduce the treatment cost and consequent suffering of patients. Dermoscopy or skin surface microscopy provides in vivo inspection of color and morphologic structures of pigmented skin lesions (PSLs), rendering higher accuracy for detecting suspicious cases than it is possible via inspecting with naked eye. However, interpretation of dermoscopic images is time consuming and subjective, even for trained dermatologists. Therefore, there is currently a great interest in the development of computeraided diagnosis (CAD) systems for automated melanoma recognition. However, the majority of the CAD systems are still in the early development stage with lack of descriptive feature generation and benchmark evaluation in ground-truth datasets. This work is focusing on by addressing the various issues related to the development of such a CAD system with effective feature extraction from Non-Subsampled Contourlet Transform (NSCT) and Eig(Hess) histogram of oriented gradients (HOG) and lesion classification with efficient Extreme Learning Machine (ELM) due to its good generalization abilities and a high learning efficiency and evaluating its effectiveness in a benchmark data set of dermoscopic images towards the goal of realistic comparison and real clinical integration. The proposed research on melanoma recognition has huge potential for offering powerful services that would significantly benefit the present Biomedical Information Systems.
Schnider, Nicole; Forrer, Fiona Alena; Brägger, Urs; Hicklin, Stefan Paul
The aim of this study was to evaluate the clinical performance of one-piece, screw-retained implant crowns based on hand-veneered computer-aided design/computer-aided manufacture (CAD/CAM) zirconium dioxide abutments with a crossfit connection at least 1 year after insertion of the crown. Consecutive patients who had received at least one Straumann bone level implant and one-piece, screw-retained implant crowns fabricated with CARES zirconium dioxide abutments were reexamined. Patient satisfaction, occlusal and peri-implant parameters, mechanical and biologic complications, radiologic parameters, and esthetics were recorded. A total of 50 implant crowns in the anterior and premolar region were examined in 41 patients. The follow-up period of the definitive reconstructions ranged from 1.1 to 3.8 years. No technical and no biologic complications had occurred. At the reexamination, 100% of the implants and reconstructions were in situ. Radiographic evaluation revealed a mean distance from the implant shoulder to the first visible bone-to-implant contact of 0.06 mm at the follow-up examination. Screw-retained crowns based on veneered CAD/CAM zirconium dioxide abutments with a crossfit connection seem to be a promising way to replace missing teeth in the anterior and premolar region. In the short term, neither failures of components nor complications were noted, and the clinical and radiographic data revealed stable hard and soft tissue conditions.
Pietruski, Jan K; Skurska, Anna; Bernaczyk, Anna; Milewski, Robert; Pietruska, Maria Julia; Gehrke, Peter; Pietruska, Małgorzata D
2018-05-02
While working on CAD/CAM-customized abutments, the use of standard impression copings with a circular diameter produces inconsistency within the emergence profile. It may begin with a collapse of the supra-implant mucosa during impression taking, then lead to a computer-generated mismatch of the position and outline of the abutment shoulder, and consequently result in a compromised outcome of anticipated treatment. The aim of the study was to compare the virtual and clinical positions of the abutment shoulder in relation to the mucosal margin after the abutment delivery. Conventional open-tray impression takings followed uncovering surgery. Master casts were scanned with a desktop scanner. Clinical examinations took place after abutment's insertion and temporization (T1) and prior to cementation of the definitive crown (T2). The distances between the abutment shoulder and marginal soft tissue were measured intraorally in four aspects and juxtaposed with those on the virtual model. The study evaluated 257 dental implants and CAD/CAM-customized abutments. As T1 and T2 showed, there was a positive correlation between the virtually designed abutment shoulder position and matching clinical location relative to the mucosal margin. In 42.1% of cases, the distance between the mucosal margin and the abutment shoulder did not change. It increased in 36.3% of cases while a decrease occurred in 21.6% of them. Computer-set position of the abutment shoulder in relation to the mucosal margin can be predictably implemented in clinical practice.
Effect of nutritional status on mortality in patients undergoing coronary artery bypass grafting.
Keskin, Muhammed; İpek, Göktük; Aldağ, Mustafa; Altay, Servet; Hayıroğlu, Mert İlker; Börklü, Edibe Betül; İnan, Duygu; Kozan, Ömer
2018-04-01
The prognostic effects of poor nutritional status and cardiac cachexia on coronary artery disease (CAD) are not clearly understood. A well-accepted nutritional status parameter, the prognostic nutritional index (PNI), which was first demonstrated to be valuable in patients with cancer and those undergoing gastrointestinal surgery, was introduced to patients requiring coronary artery bypass grafting (CABG). The aim of the present study was to evaluate the prognostic value of PNI in patients with CAD undergoing CABG. We evaluated the in-hospital and long-term (3-y) prognostic effect of PNI on 644 patients with CAD undergoing CABG. Baseline characteristics and outcomes were compared among the patients by PNI and categorized accordingly: Q1, Q2, Q3, and Q4. Patients with lower PNI had significantly higher in-hospital and long-term mortality. Patients with lower PNI levels (Q1) had higher in-hospital mortality and had 12 times higher mortality rates than those with higher PNI levels (Q4). The higher PNI group had the lower rates and was used as the reference. Long-term mortality was higher in patients with lower PNI (Q1)-4.9 times higher than in the higher PNI group (Q4). In-hospital and long-term mortality rates were similar in the non-lower PNI groups (Q2-4). The present study demonstrated that PNI, calculated based on serum albumin level and lymphocyte count, is an independent prognostic factor for mortality in patients undergoing CABG. Copyright © 2017 Elsevier Inc. All rights reserved.
The effect of porcelain firing and type of finish line on the marginal fit of zirconia copings.
Vojdani, Mahroo; Safari, Anahita; Mohaghegh, Mina; Pardis, Soheil; Mahdavi, Farideh
2015-06-01
Although all-ceramic restorations are broadly used, there is a lack of information concerning how their fit is affected by fabrication procedure and marginal configuration. The purpose of this study was to evaluate the marginal fit of zirconia CAD/CAM ceramic crowns before and after porcelain firing. The influence of finish line configuration on the marginal fit was also evaluated. Twenty standardized zirconia CAD/CAM copings were fabricated for chamfer and shoulder finish line designs (n=10). The marginal fit of specimens was measured on 18 points, marked on the master metal die by using a digital microscope. After the crowns were finalized by porcelain veneering, the measurements of marginal fit were performed again. The means and standard deviations were calculated and data were analyzed using student's t-test and paired t-test (α=0.05). There were significant differences between marginal fit of chamfer and shoulder finish line groups before and after porcelain firing (p= 0.014 and p= 0.000, respectively). The marginal gap of copings with shoulder finish line was significantly smaller than those with chamfer configuration (p= 0.000), but there were no significant differences between the two marginal designs, after porcelain firing (p= 0.341). Porcelain veneering was found to have a statistically significant influence on the marginal fit of zirconia CAD/CAM crowns. Both margin configurations showed marginal gaps that were within a reported clinically acceptable range of marginal discrepancy.
Reliability Estimation for Single-unit Ceramic Crown Restorations
Lekesiz, H.
2014-01-01
The objective of this study was to evaluate the potential of a survival prediction method for the assessment of ceramic dental restorations. For this purpose, fast-fracture and fatigue reliabilities for 2 bilayer (metal ceramic alloy core veneered with fluorapatite leucite glass-ceramic, d.Sign/d.Sign-67, by Ivoclar; glass-infiltrated alumina core veneered with feldspathic porcelain, VM7/In-Ceram Alumina, by Vita) and 3 monolithic (leucite-reinforced glass-ceramic, Empress, and ProCAD, by Ivoclar; lithium-disilicate glass-ceramic, Empress 2, by Ivoclar) single posterior crown restorations were predicted, and fatigue predictions were compared with the long-term clinical data presented in the literature. Both perfectly bonded and completely debonded cases were analyzed for evaluation of the influence of the adhesive/restoration bonding quality on estimations. Material constants and stress distributions required for predictions were calculated from biaxial tests and finite element analysis, respectively. Based on the predictions, In-Ceram Alumina presents the best fast-fracture resistance, and ProCAD presents a comparable resistance for perfect bonding; however, ProCAD shows a significant reduction of resistance in case of complete debonding. Nevertheless, it is still better than Empress and comparable with Empress 2. In-Ceram Alumina and d.Sign have the highest long-term reliability, with almost 100% survivability even after 10 years. When compared with clinical failure rates reported in the literature, predictions show a promising match with clinical data, and this indicates the soundness of the settings used in the proposed predictions. PMID:25048249
On the Design of a CADS for Shoulder Pain Pathology
NASA Astrophysics Data System (ADS)
de Ipiña, K. López; Hernández, M. C.; Martínez, E.; Vaquero, C.
A musculoskeletal disorder is a condition of the musculoskeletal system, which consists in part of it being injured continuously over time. Shoulder disorders are one of the most common musculoskeletal cases attended in primary health care services. Shoulder disorders cause pain and limit the ability to perform many routine activities, affecting about 15-25 % of the general population. Several clinical tests have been described to aid diagnosis of shoulder disorders. However, the current literature acknowledges a lack of concordance in clinical assessment, even among musculoskeletal specialists. We are working on the design of a Computer-Aided Decision Support (CADS) system for Shoulder Pain Pathology. The paper presents the results of our efforts to build a CADS system testing several classical classification paradigms, feature reduction methods (PCA) and K-means unsupervised clustering. The small database size imposes the use of robust covariance matrix estimation methods to improve the system performance. Finally, the system was evaluated by a medical specialist.
NASA Astrophysics Data System (ADS)
Land, Walker H., Jr.; Anderson, Frances; Smith, Tom; Fahlbusch, Stephen; Choma, Robert; Wong, Lut
2005-04-01
Achieving consistent and correct database cases is crucial to the correct evaluation of any computer-assisted diagnostic (CAD) paradigm. This paper describes the application of artificial intelligence (AI), knowledge engineering (KE) and knowledge representation (KR) to a data set of ~2500 cases from six separate hospitals, with the objective of removing/reducing inconsistent outlier data. Several support vector machine (SVM) kernels were used to measure diagnostic performance of the original and a "cleaned" data set. Specifically, KE and ER principles were applied to the two data sets which were re-examined with respect to the environment and agents. One data set was found to contain 25 non-characterizable sets. The other data set contained 180 non-characterizable sets. CAD system performance was measured with both the original and "cleaned" data sets using two SVM kernels as well as a multivariate probabilistic neural network (PNN). Results demonstrated: (i) a 10% average improvement in overall Az and (ii) approximately a 50% average improvement in partial Az.
NASA Astrophysics Data System (ADS)
Ciany, Charles M.; Zurawski, William; Kerfoot, Ian
2001-10-01
The performance of Computer Aided Detection/Computer Aided Classification (CAD/CAC) Fusion algorithms on side-scan sonar images was evaluated using data taken at the Navy's's Fleet Battle Exercise-Hotel held in Panama City, Florida, in August 2000. A 2-of-3 binary fusion algorithm is shown to provide robust performance. The algorithm accepts the classification decisions and associated contact locations form three different CAD/CAC algorithms, clusters the contacts based on Euclidian distance, and then declares a valid target when a clustered contact is declared by at least 2 of the 3 individual algorithms. This simple binary fusion provided a 96 percent probability of correct classification at a false alarm rate of 0.14 false alarms per image per side. The performance represented a 3.8:1 reduction in false alarms over the best performing single CAD/CAC algorithm, with no loss in probability of correct classification.
Evaluation of an Anthropometric Human Body Model for Simulated EVA Task Assessment
NASA Technical Reports Server (NTRS)
Etter, Brad
1996-01-01
One of the more mission-critical tasks performed in space is extravehicular activity (EVA) which requires the astronaut to be external to the station or spacecraft, and subsequently at risk from the many threats posed by space. These threats include, but are not limited to: no significant atmosphere, harmful electromagnetic radiation, micrometeoroids, and space debris. To protect the astronaut from this environment, a special EVA suit is worn which is designed to maintain a sustainable atmosphere (at 1/3 atmosphere) and provide protection against the hazards of space. While the EVA suit serves these functions well, it does impose limitations on the astronaut as a consequence of the safety it provides. Since the astronaut is in a virtual vacuum, any atmospheric pressure inside the suit serves to pressurize the suit and restricts mobility of flexible joints (such as fabric). Although some of the EVA suit joints are fixed, rotary-style joints, most of the mobility is achieved by the simple flexibility of the fabric. There are multiple layers of fabric, each of which serves a special purpose in the safety of the astronaut. These multiple layers add to the restriction of motion the astronaut experiences in the space environment. Ground-based testing is implemented to evaluate the capability of EVA-suited astronauts to perform the various tasks in space. In addition to the restriction of motion imposed by the EVA suit, most EVA activity is performed in a micro-gravity (weight less) environment. To simulate weightlessness EVA-suited testing is performed in a neutral buoyancy simulator (NBS). The NBS is composed of a large container of water (pool) in which a weightless environment can be simulated. A subject is normally buoyant in the pressurized suit; however he/she can be made neutrally buoyant with the addition of weights. In addition, most objects the astronaut must interface with in the NBS sink in water and flotation must be added to render them "weightless". The implementation of NBS testing has proven to invaluable in the assessment of EVA activities performed with the Orbiter and is considered to be a key step in the construction of the International Space Station (ISS). While the NBS testing is extremely valuable, it does require considerable overhead to maintain and operate. It has been estimated that the cost of utilizing the facility is approximately $10,000 per day. Therefore it is important to maximize the utility of NBS testing for optimal results. One important aspect to consider in any human/worksite interface is the considerable wealth of anthropometric and ergonomic data available. A subset of this information specific to EVA activity is available in NASA standard 3000. The difficulty in implementing this data is that most of the anthropometric information is represented in a two-dimensional format. This poses some limitations in complete evaluation of the astronaut's capabilities in a three-dimensional environment. Advances in computer hardware and software have provided for three-dimensional design and implementation of hardware with the advance of computer aided design (CAD) software. There are a number of CAD products available and most companies and agencies have adopted CAD as a fundamental aspect of the design process. Another factor which supports the use of CAD is the implementation of computer aided manufacturing (CAM) software and hardware which provides for rapid prototyping and decreases the time to product in the design process. It is probable that most hardware to be accessed by astronauts in EVA or IVA (intravehicular activity) has been designed by a CAD system, and is therefore represented in three-dimensional space for evaluation. Because of the implementation of CAD systems and the movement towards early prototyping, a need has arisen in industry and government for tools which facilitate the evaluation of ergonomic consideration in a three-dimensional environment where the hardware has been designed by the CAD tools. One such product is Jack which was developed by the University of Pennsylvania with funding from several government agencies, including NASA. While the primary purpose of Jack is to model human figures in a ground-based (gravity) environment, it can be utilized to evaluate EVA-suited activities as well. The effects of simulated gravity must be turned off by turning off "behaviors". Although Jack provides human figures for manipulation, the primary instrument to be evaluated for EVA mobility is the work envelope provided by the EVA suit. An EVA Jack suit model has been developed by NASA-JSC and was utilized in this study. This suit model provided a more restrictive motion environment as expected for an EVA suited subject. As part of this study, the anthropometric dimensions for a 50th percentile male were compared with basic anthropometric data and were found to be representative for the population group expected in the NASA flight program. The joints for the suit were created in a manner which provided consistent performance with EVA reach envelopes published in NASA standard #3000.
Knuuti, Juhani; Ballo, Haitham; Juarez-Orozco, Luis Eduardo; Saraste, Antti; Kolh, Philippe; Rutjes, Anne Wilhelmina Saskia; Jüni, Peter; Windecker, Stephan; Bax, Jeroen J; Wijns, William
2018-05-29
To determine the ranges of pre-test probability (PTP) of coronary artery disease (CAD) in which stress electrocardiogram (ECG), stress echocardiography, coronary computed tomography angiography (CCTA), single-photon emission computed tomography (SPECT), positron emission tomography (PET), and cardiac magnetic resonance (CMR) can reclassify patients into a post-test probability that defines (>85%) or excludes (<15%) anatomically (defined by visual evaluation of invasive coronary angiography [ICA]) and functionally (defined by a fractional flow reserve [FFR] ≤0.8) significant CAD. A broad search in electronic databases until August 2017 was performed. Studies on the aforementioned techniques in >100 patients with stable CAD that utilized either ICA or ICA with FFR measurement as reference, were included. Study-level data was pooled using a hierarchical bivariate random-effects model and likelihood ratios were obtained for each technique. The PTP ranges for each technique to rule-in or rule-out significant CAD were defined. A total of 28 664 patients from 132 studies that used ICA as reference and 4131 from 23 studies using FFR, were analysed. Stress ECG can rule-in and rule-out anatomically significant CAD only when PTP is ≥80% (76-83) and ≤19% (15-25), respectively. Coronary computed tomography angiography is able to rule-in anatomic CAD at a PTP ≥58% (45-70) and rule-out at a PTP ≤80% (65-94). The corresponding PTP values for functionally significant CAD were ≥75% (67-83) and ≤57% (40-72) for CCTA, and ≥71% (59-81) and ≤27 (24-31) for ICA, demonstrating poorer performance of anatomic imaging against FFR. In contrast, functional imaging techniques (PET, stress CMR, and SPECT) are able to rule-in functionally significant CAD when PTP is ≥46-59% and rule-out when PTP is ≤34-57%. The various diagnostic modalities have different optimal performance ranges for the detection of anatomically and functionally significant CAD. Stress ECG appears to have very limited diagnostic power. The selection of a diagnostic technique for any given patient to rule-in or rule-out CAD should be based on the optimal PTP range for each test and on the assumed reference standard.
Lee, Ki-Sun; Shin, Sang-Wan; Lee, Sang-Pyo; Kim, Jong-Eun; Kim, Jee-Hwan; Lee, Jeong-Yol
The purpose of this pilot study was to evaluate and compare polyetherketoneketone (PEKK) with different framework materials for implant-supported prostheses by means of a three-dimensional finite element analysis (3D-FEA) based on cone beam computed tomography (CBCT) and computer-aided design (CAD) data. A geometric model that consisted of four maxillary implants supporting a prosthesis framework was constructed from CBCT and CAD data of a treated patient. Three different materials (zirconia, titanium, and PEKK) were selected, and their material properties were simulated using FEA software in the generated geometric model. In the PEKK framework (ie, low elastic modulus) group, the stress transferred to the implant and simulated adjacent tissue was reduced when compressive stress was dominant, but increased when tensile stress was dominant. This study suggests that the shock-absorbing effects of a resilient implant-supported framework are limited in some areas and that rigid framework material shows a favorable stress distribution and safety of overall components of the prosthesis.
Horsch, Alexander; Hapfelmeier, Alexander; Elter, Matthias
2011-11-01
Breast cancer is globally a major threat for women's health. Screening and adequate follow-up can significantly reduce the mortality from breast cancer. Human second reading of screening mammograms can increase breast cancer detection rates, whereas this has not been proven for current computer-aided detection systems as "second reader". Critical factors include the detection accuracy of the systems and the screening experience and training of the radiologist with the system. When assessing the performance of systems and system components, the choice of evaluation methods is particularly critical. Core assets herein are reference image databases and statistical methods. We have analyzed characteristics and usage of the currently largest publicly available mammography database, the Digital Database for Screening Mammography (DDSM) from the University of South Florida, in literature indexed in Medline, IEEE Xplore, SpringerLink, and SPIE, with respect to type of computer-aided diagnosis (CAD) (detection, CADe, or diagnostics, CADx), selection of database subsets, choice of evaluation method, and quality of descriptions. 59 publications presenting 106 evaluation studies met our selection criteria. In 54 studies (50.9%), the selection of test items (cases, images, regions of interest) extracted from the DDSM was not reproducible. Only 2 CADx studies, not any CADe studies, used the entire DDSM. The number of test items varies from 100 to 6000. Different statistical evaluation methods are chosen. Most common are train/test (34.9% of the studies), leave-one-out (23.6%), and N-fold cross-validation (18.9%). Database-related terminology tends to be imprecise or ambiguous, especially regarding the term "case". Overall, both the use of the DDSM as data source for evaluation of mammography CAD systems, and the application of statistical evaluation methods were found highly diverse. Results reported from different studies are therefore hardly comparable. Drawbacks of the DDSM (e.g. varying quality of lesion annotations) may contribute to the reasons. But larger bias seems to be caused by authors' own decisions upon study design. RECOMMENDATIONS/CONCLUSION: For future evaluation studies, we derive a set of 13 recommendations concerning the construction and usage of a test database, as well as the application of statistical evaluation methods.
Longo, F; Nicetto, T; Banzato, T; Savio, G; Drigo, M; Meneghello, R; Concheri, G; Isola, M
2018-02-01
The aim of this ex vivo study was to test a novel three-dimensional (3D) automated computer-aided design (CAD) method (aCAD) for the computation of femoral angles in dogs from 3D reconstructions of computed tomography (CT) images. The repeatability and reproducibility of three manual radiography, manual CT reconstructions and the aCAD method for the measurement of three femoral angles were evaluated: (1) anatomical lateral distal femoral angle (aLDFA); (2) femoral neck angle (FNA); and (3) femoral torsion angle (FTA). Femoral angles of 22 femurs obtained from 16 cadavers were measured by three blinded observers. Measurements were repeated three times by each observer for each diagnostic technique. Femoral angle measurements were analysed using a mixed effects linear model for repeated measures to determine the levels of intra-observer agreement (repeatability) and inter-observer agreement (reproducibility). Repeatability and reproducibility of measurements using the aCAD method were excellent (intra-class coefficients, ICCs≥0.98) for all three angles assessed. Manual radiography and CT exhibited excellent agreement for the aLDFA measurement (ICCs≥0.90). However, FNA repeatability and reproducibility were poor (ICCs<0.8), whereas FTA measurement showed slightly higher ICCs values, except for the radiographic reproducibility, which was poor (ICCs<0.8). The computation of the 3D aCAD method provided the highest repeatability and reproducibility among the tested methodologies. Copyright © 2017 Elsevier Ltd. All rights reserved.
A hybrid deep learning approach to predict malignancy of breast lesions using mammograms
NASA Astrophysics Data System (ADS)
Wang, Yunzhi; Heidari, Morteza; Mirniaharikandehei, Seyedehnafiseh; Gong, Jing; Qian, Wei; Qiu, Yuchen; Zheng, Bin
2018-03-01
Applying deep learning technology to medical imaging informatics field has been recently attracting extensive research interest. However, the limited medical image dataset size often reduces performance and robustness of the deep learning based computer-aided detection and/or diagnosis (CAD) schemes. In attempt to address this technical challenge, this study aims to develop and evaluate a new hybrid deep learning based CAD approach to predict likelihood of a breast lesion detected on mammogram being malignant. In this approach, a deep Convolutional Neural Network (CNN) was firstly pre-trained using the ImageNet dataset and serve as a feature extractor. A pseudo-color Region of Interest (ROI) method was used to generate ROIs with RGB channels from the mammographic images as the input to the pre-trained deep network. The transferred CNN features from different layers of the CNN were then obtained and a linear support vector machine (SVM) was trained for the prediction task. By applying to a dataset involving 301 suspicious breast lesions and using a leave-one-case-out validation method, the areas under the ROC curves (AUC) = 0.762 and 0.792 using the traditional CAD scheme and the proposed deep learning based CAD scheme, respectively. An ensemble classifier that combines the classification scores generated by the two schemes yielded an improved AUC value of 0.813. The study results demonstrated feasibility and potentially improved performance of applying a new hybrid deep learning approach to develop CAD scheme using a relatively small dataset of medical images.
Huang, P J; Chieng, P U; Lee, Y T; Chiang, F T; Tseng, Y Z; Liau, C S; Tseng, C D; Su, C T; Lien, W P
1992-11-01
Exercise thallium-201 imaging using single-photon emission computed tomography (SPECT) was evaluated in 154 patients with angiographically documented coronary artery disease (CAD) and in 25 normal subjects. Of the 154 patients with CAD, 134 (87%) had abnormal thallium images. By contrast, only 77 (50%) patients had ischemic ST-segment depression (p < 0.001). Among 25 normal subjects, 20 had normal exercise SPECT images. The specificity of exercise SPECT imaging (80% or 20/25) in excluding patients with CAD was not significantly higher than that of exercise electrocardiography (76% or 19/25). For the detection of individual vessel involvement by analysis of territories of perfusion abnormalities, the sensitivity and specificity of exercise SPECT were 72% and 96% for the left anterior descending, 78% and 85% for the right coronary, and 47% and 98% for the left circumflex artery. Ninety (group 1) of the 154 patients with CAD achieved adequate exercise end points (ischemic ST-segment depression or > 85% of maximal predicted heart rate) and 64 (group 2) did not. Exercise SPECT showed significantly more perfusion abnormalities in group 1 than in group 2 (96% vs 75%, p < 0.001). We conclude that: (1) exercise SPECT thallium imaging is more sensitive than exercise electrocardiography for detecting patients with CAD; (2) the sensitivity of the test is affected by the level of exercise; and (3) it is valuable in the identification of individual vessel involvement.
Wasiluk, Grzegorz; Chomik, Ewa; Gehrke, Peter; Pietruska, Małgorzata; Skurska, Anna; Pietruski, Jan
2017-07-01
The aim of this study was to assess the frequency of cement residues after cementation of CAD/CAM monolithic zirconia crowns on customized CAD/CAM titanium abutments. Sixty premolars and molars were restored on Astra Tech Osseospeed TX ™ implants using single monolithic zirconia crowns fixed on two types of custom-made abutments: Atlantis ™ titanium or Atlantis ™ Gold Hue. Occlusal openings providing access to the abutment screws were designed for retrievability of the crown/abutment connection. After fixation with glass ionomer cement, the crown/abutment units were unscrewed to evaluate the presence of residual cement. Dichotomous assessment of the presence or absence of cement at the crown/abutment unit and peri-implant tissues was performed. Clinically undetected cement excess was visible on 44 of 60 restorations (73.3%). There was no interdependency between residual cement presence and implant location or diameter. However, a dependency between the presence of residual cement and the aspect of the abutment/crown connection could be noted. The majority of the residues were observed on the distal (17.9%) and mesial (15%) aspects. While on the palatal/lingual aspect, the cement was visible in 8.8%; only 3.4% of all surfaces displayed cement residues. Within the limitations of the study, it can be concluded that the use of customized CAD/CAM abutments do not guarantee avoidance of subgingival cement residues after crown cementation. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Chaikriangkrai, Kongkiat; Kassi, Mahwash; Alchalabi, Sama; Bala, Sayf Khaleel; Adigun, Rosalyn; Botero, Sharleen; Chang, Su Min
2014-01-01
Background: Atherosclerotic coronary artery disease (CAD) has long been shown to involve chronic low-grade subclinical inflammation. However, whether there is association between hematological indices assessed by complete blood count (CBC) and coronary atherosclerotic burden has not been well studied. Materials and Methods: Consecutive 868 patients without known CAD who presented with acute chest pain to emergency department and underwent coronary artery calcium (CAC) scoring evaluation by multi-detector cardiac computed tomography were included in our study. Clinical characteristics and CBC indices were compared among different CAC groups. Results: The cohort comprised 60% male with a mean age of 61 (SD = 14) years. Median Framingham risk of CAD was 4% (range 1-16%). Median CAC score was 0 (IQR 0-43). Higher CAC groups had significantly higher Framingham risk of CAD than lower CAC groups (P < 0.001). Among different CAC categories, there was no statistically significant difference in hemoglobin level (p 0.45), mean corpuscular volume (p 0.43), mean corpuscular hemoglobin (p 0.28), mean corpuscular hemoglobin volume (p 0.36), red cell distribution width (0.42), total white blood cell counts (p 0.291), neutrophil counts (p 0.352), lymphocyte counts (p 0.92), neutrophil to lymphocyte ratio (p 0.68), monocyte count (p 0.48), and platelet counts (p 0.25). Conclusion: Our study did not detect significant association between hematological indices assessed with CBC and coronary calcification in symptomatic patients without known CAD. PMID:25317386
Dewailly, Marion; Rémy-Jardin, Martine; Duhamel, Alain; Faivre, Jean-Baptiste; Pontana, François; Deken, Valérie; Bakai, Anne-Marie; Remy, Jacques
2010-01-01
To evaluate the performance of a computer-aided detection (CAD) system for diagnosing peripheral acute pulmonary embolism (PE) with a 64-slice multi-detector row computed tomography (CT). Two radiologists investigated the accuracy of a software aimed at detecting peripheral clots (PECAD prototype, version 7; Siemens Medical Systems, Forchheim, Germany) by applying this tool for the analysis of the pulmonary arterial bed of 74 CT angiograms obtained with 64-slice dual-source CT (Definition; Siemens Medical Systems). These cases were retrospectively selected from a database of CT studies performed on the same CT unit, with a similar collimation (64 x 0.6 mm) and similar injection protocols. Patient selection was based on a variety of (1) scanning conditions, namely, nongated (n = 30), electrocardiography-gated (n = 30), and dual-energy CT angiograms (n = 14), and (2) image quality (IQ), namely, scans of excellent IQ (n = 53) and lower IQ due to lower levels of arterial enhancement and/or presence of noise (n = 21). The standard of truth was based on the 2 radiologists' consensus reading and the results of CAD. The software detected 80 of 93 peripheral clots present in the 21 patients (42 segmental and 38 subsegmental clots). The overall sensitivity (95% confidence interval) of the CAD tool was 86% (77%-92%) for detecting peripheral clots, 78% (64.5%-88%) at the segmental level and 97% (85.5%-99.9%) at the subsegmental level. Assuming normal vascular anatomy with 20 segmental and 40 subsegmental arteries, overall specificity and positive and negative predictive values (95% confidence interval) of the software were 91.8% (91%-92.6%), 18.4% (15%-22.4%), and 99.7% (99.5%-99.8%), respectively. A mean of 5.4 false positives was found per patient (total, 354 false positives), mainly linked to the presence of perivascular connective tissue (n = 119; 34%) and perivascular airspace consolidation (n = 97; 27%). The sensitivities (95% confidence interval) for the CAD tool were 91% (69.8%-99.3%) for dual-energy, 87% (59.3%-93.2%) for electrocardiography-gated, and 87% (73.5%-95.3%) for nongated scans (P > 0.05). No significant difference was found in the sensitivity of the CAD software when comparing the scans according to the scanning conditions and image quality. The evaluated CAD software has a good sensitivity in detecting peripheral PE, which is not influenced by the scanning conditions or the overall image quality.
In vitro evaluation of the marginal integrity of CAD/CAM interim crowns.
Kelvin Khng, Kwang Yong; Ettinger, Ronald L; Armstrong, Steven R; Lindquist, Terry; Gratton, David G; Qian, Fang
2016-05-01
The accuracy of interim crowns made with computer-aided design and computer-aided manufacturing (CAD/CAM) systems has not been well investigated. The purpose of this in vitro study was to evaluate the marginal integrity of interim crowns made by CAD/CAM compared with that of conventional polymethylmethacrylate (PMMA) crowns. A dentoform mandibular left second premolar was prepared for a ceramic crown and scanned for the fabrication of 60 stereolithical resin dies, half of which were scanned to fabricate 15 Telio CAD-CEREC and 15 Paradigm MZ100-E4D-E4D crowns. Fifteen Caulk and 15 Jet interim crowns were made on the remaining resin dies. All crowns were cemented with Tempgrip under a 17.8-N load, thermocycled for 1000 cycles, placed in 0.5% acid fuschin for 24 hours, and embedded in epoxy resin before sectioning from the mid-buccal to mid-lingual surface. The marginal discrepancy was measured using a traveling microscope, and dye penetration was measured as a percentage of the overall length under the crown. The mean vertical marginal discrepancy of the conventionally made interim crowns was greater than for the CAD/CAM crowns (P=.006), while no difference was found for the horizontal component (P=.276). The mean vertical marginal discrepancy at the facial surface of the Caulk crowns was significantly greater than that of the other 3 types of interim crowns (P<.001). At the facial margin, the mean horizontal component of the Telio crowns was significantly larger than that of the other 3 types, with no difference at the lingual margins (P=.150). The mean percentage dye penetration for the Paradigm MZ100-E4D crowns was significantly greater and for Jet crowns significantly smaller than for the other 3 crowns (P<.001). However, the mean percentage dye penetration was significantly correlated with the vertical and horizontal marginal discrepancies of the Jet interim crowns at the facial surface and with the horizontal marginal discrepancies of the Caulk interim crowns at the lingual surface (P<.01 in each instance). A significantly smaller vertical marginal discrepancy was found with the interim crowns fabricated by CAD/CAM as compared with PMMA crowns; however, this difference was not observed for the horizontal component. The percentage dye penetration was correlated with vertical and horizontal discrepancies at the facial surface for the Jet interim crowns and with horizontal discrepancies at the lingual surface for the Caulk interim crowns. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Ardesjö-Lundgren, Brita; Tengvall, Katarina; Bergvall, Kerstin; Farias, Fabiana H G; Wang, Liya; Hedhammar, Åke; Lindblad-Toh, Kerstin; Andersson, Göran
2017-08-01
Canine atopic dermatitis (CAD) is an inflammatory and pruritic allergic skin disease caused by interactions between genetic and environmental factors. Previously, a genome-wide significant risk locus on canine chromosome 27 for CAD was identified in German shepherd dogs (GSDs) and Plakophilin-2 (PKP2) was defined as the top candidate gene. PKP2 constitutes a crucial component of desmosomes and also is important in signalling, metabolic and transcriptional activities. The main objective was to evaluate the role of PKP2 in CAD by investigating PKP2 expression and desmosome structure in nonlesional skin from CAD-affected (carrying the top GWAS SNP risk allele) and healthy GSDs. We also aimed at defining the cell types in the skin that express PKP2 and its intracellular location. Skin biopsies were collected from nine CAD-affected and five control GSDs. The biopsies were frozen for immunofluorescence and fixed for electron microscopy immunolabelling and morphology. We observed the novel finding of PKP2 expression in dendritic cells and T cells in dog skin. Moreover, we detected that PKP2 was more evenly expressed within keratinocytes compared to its desmosomal binding-partner plakoglobin. PKP2 protein was located in the nucleus and on keratin filaments attached to desmosomes. No difference in PKP2 abundance between CAD cases and controls was observed. Plakophilin-2 protein in dog skin is expressed in both epithelial and immune cells; based on its subcellular location its functional role is implicated in both nuclear and structural processes. © 2017 The Authors. Veterinary Dermatology published by John Wiley & Sons Ltd on behalf of the ESVD and ACVD.
Barros, Marcos Roberto Andrade Costa; Bertolami, Marcelo Chiara; Abdalla, Dulcinéia Saes Parra; Ferreira, Waldinai Pereira
2006-01-01
Oxidative modification of low-density lipoproteins (LDL) is an essential step in atherogenesis, generating minimally oxidized LDL, also called electronegative LDL [LDL(-)], which has chemotactic, cytotoxic and immunogenic properties. Serum LDL(-) and anti-LDL(-) auto-antibodies (IgG) were evaluated in 28 children and adolescents with familial hypercholesterolemia (FH) antecedents, with or without early coronary artery disease in first-degree relatives (eCAD), hypercholesterolemic (hc) or normocholesterolemic (nc) versus a control group of normocholesterolemic children without pathologic antecedents (C). ELISA method was used for detection of LDL(-) and anti-LDL(-) IgG. LDL(-) serum levels did not differ among the four groups (FH-eCAD-hc 41.4 +/- 24.9 microg/dl; FH-hc 38.3 +/- 11.2 microg/dl; FH-nc 47.3 +/- 17.0 microg/dl and C 44.2 +/- 28.8 microg/dl, p = 0.659). However, IgG anti-LDL(-) auto-antibodies were significantly higher in the control group in comparison to the FH groups with or without eCAD, independent of hypercholesterolemia or normocholesterolemia (FH-eCAD-hc 0.825 +/- 0.289 microg/dl; FH-hc 0.667 +/- 0.307 microg/dl; FH-nc 0.763 +/- 0.204 microg/dl and C 1.105 +/- 0.233 microg/dl, p = 0.006). When the auto-antibodies of groups with FH, with or without eCAD and with or without hypercholesterolemia were compared, no differences were found (p = 0.509). These results showed that FH and/or eCAD children and adolescents have lower titers of auto-antibodies anti-LDL(-) than children from normal families, independent of serum LDL-cholesterol or serum LDL(-).
Biaxial flexural strength of CAD/CAM ceramics.
Buso, L; Oliveira-Júnior, O B; Hiroshi Fujiy, F; Leão Lombardo, G H; Ramalho Sarmento, H; Campos, F; Assunção Souza, R O
2011-06-01
Aim of the study was to evaluate the biaxial flexural strength of ceramics processed using the Cerec inLab system. The hypothesis was that the flexural strength would be influenced by the type of ceramic. Ten samples (ISO 6872) of each ceramic (N.=50/n.=10) were made using Cerec inLab (software Cerec 3D) (Ø:15 mm, thickness: 1.2 mm). Three silica-based ceramics (Vita Mark II [VM], ProCad [PC] and e-max CAD ECAD]) and two yttria-stabilized tetragonal-zirconia-polycrystalline ceramics (Y-TZP) (e-max ZirCad [ZrCAD] and Vita In-Ceram 2000 YZ Cubes [VYZ]) were tested. The samples were finished with wet silicone carbide papers up to 1 200-grit and polished in a polishing machine with diamond paste (3 µm). The samples were then submitted to biaxial flexural strength testing in a universal testing machine (EMIC), 1 mm/min. The data (MPa) were analyzed using the Kruskal-Wallis and Dunn (5%) tests. Scanning electronic microscopy (SEM) was performed on a representative sample from each group. The values (median, mean±sd) obtained for the experimental groups were: VM (101.7, 102.1±13.65 MPa), PC (165.2, 160±34.7 MPa), ECAD (437.2, 416.1±50.1 MPa), ZrCAD (804.2, 800.8±64.47 MPa) and VYZ (792.7, 807±100.7 MPa). The type of ceramic influenced the flexural strength values (P=0.0001). The ceramics ECADa, e-max ZrCADa and VYZa presented similar flexural strength values which were significantly higher than the other groups (PCb and VM IIb), which were similar statistically between them (Dunn's test). The hypothesis was accepted. The polycrystalline ceramics (Y-TZP) should be material chosen for make FPDs because of their higher flexural strength values.
Desai, Sonali P; Januzzi, James L; Pande, Ashvin N; Pomerantsev, Eugene V; Resnic, Frederic S; Fossel, Anne; Chibnik, Lori B; Solomon, Daniel H
2010-12-01
Rheumatoid arthritis (RA) is associated with an increased prevalence of coronary artery disease (CAD). We investigated the presenting symptoms of CAD, coronary anatomy (single versus multi-vessel CAD), and treatment among a group of subjects undergoing percutaneous coronary intervention (PCI) with angioplasty and/or stenting. We evaluated a retrospective cohort of 43 RA subjects and 43 matched non-RA subjects undergoing PCI at 2 academic referral centers. RA subjects were matched to non-RA subjects on age, gender, history of coronary artery bypass grafting, date of PCI, and interventional cardiologist. We compared cardiac risk factors, presentation, treatment, and outcomes. The mean age of the study cohort was 71 ± 10 years, and the distribution of traditional cardiac risk factors was similar in the subjects with RA compared with the matched non-RA subjects (all P values > 0.05). Seventy-four percent of subjects with RA compared with 67% of those without RA presented with an acute coronary syndrome before PCI (P = 0.48). All subjects in this cohort undergoing PCI had at least 1 stenosis in a major epicardial vessel and similar percentages of subjects with RA (44%) and without RA (40%) had multi-vessel CAD (P = 0.66). The administration of cardiac medications both at PCI and at hospital discharge was not different among subjects with RA compared with matched non-RA subjects. Among this cohort with significant CAD undergoing PCI, clinical characteristics, presentation, severity of CAD, treatment modalities, and outcomes were similar in subjects with RA and well-matched non-RA subjects. Copyright © 2010 Elsevier Inc. All rights reserved.
Creation of system of computer-aided design for technological objects
NASA Astrophysics Data System (ADS)
Zubkova, T. M.; Tokareva, M. A.; Sultanov, N. Z.
2018-05-01
Due to the competition in the market of process equipment, its production should be flexible, retuning to various product configurations, raw materials and productivity, depending on the current market needs. This process is not possible without CAD (computer-aided design). The formation of CAD begins with planning. Synthesizing, analyzing, evaluating, converting operations, as well as visualization and decision-making operations, can be automated. Based on formal description of the design procedures, the design route in the form of an oriented graph is constructed. The decomposition of the design process, represented by the formalized description of the design procedures, makes it possible to make an informed choice of the CAD component for the solution of the task. The object-oriented approach allows us to consider the CAD as an independent system whose properties are inherited from the components. The first step determines the range of tasks to be performed by the system, and a set of components for their implementation. The second one is the configuration of the selected components. The interaction between the selected components is carried out using the CALS standards. The chosen CAD / CAE-oriented approach allows creating a single model, which is stored in the database of the subject area. Each of the integration stages is implemented as a separate functional block. The transformation of the CAD model into the model of the internal representation is realized by the block of searching for the geometric parameters of the technological machine, in which the XML-model of the construction is obtained on the basis of the feature method from the theory of image recognition. The configuration of integrated components is divided into three consecutive steps: configuring tasks, components, interfaces. The configuration of the components is realized using the theory of "soft computations" using the Mamdani fuzzy inference algorithm.
Wallace, Robert B; Wactawski-Wende, Jean; O'Sullivan, Mary Jo; Larson, Joseph C; Cochrane, Barbara; Gass, Margery; Masaki, Kamal
2011-07-01
The Women's Health Initiative (WHI) randomized clinical trial (RCT) of calcium plus vitamin D (CaD) supplements found a 17% excess in urinary tract stone incidence in the supplemented group. This study evaluated whether this risk is modified by participant characteristics. We examined the correlates of urinary tract stone occurrence in the CaD arm of the WHI trial. We analyzed an RCT involving 36,282 postmenopausal women aged 50-79 y from 40 WHI centers: 18,176 women received 500 mg calcium carbonate plus 200 IU vitamin D(3) twice daily (1000 mg and 400 IU daily, respectively), and 18,106 women received a matching placebo for an average of 7.0 y. The incidence of urinary tract stones was determined. The incidence of self-reported clinically diagnosed urinary tract stones was more common in the active CaD medication group than in the placebo group (hazard ratio: 1.17; 95% CI: 1.02, 1.34): 449 women in the CaD group and 381 women in the placebo group reported a stone during the trial. The rates of self-reported stones did not differ between various demographic, anthropomorphic, dietary, and other hypothesized risk factors according to randomization assignment. Neither the total calcium intake nor the use of calcium supplements at baseline was associated with the risk of stones. In sensitivity analyses that censored participants who were below 80% adherence, the findings were similar. Daily supplementation with CaD for 7 y was associated with an increase in the number of self-reported urinary tract stones. These findings have implications for CaD supplement use. This trial was registered with the WHI at clinicaltrials.gov as NCT00000611.
Effect of surface treatments on the bond strength of CAD/CAM fiberglass posts.
Garcia, Paula-Pontes; da Costa, Rogério-Goulart; Garcia, André-Vivan; Gonzaga, Carla-Castiglia; da Cunha, Leonardo-Fernandes; Rezende, Carlos-Eduardo-Edwards; Correr, Gisele-Maria
2018-06-01
There is no ideal protocol for the surface treatment of fiber posts, especially when using a computer-aided design/computer-aided manufacturing (CAD/CAM) experimental fiberglass block. The purpose of this study was to evaluate the bond strength of a CAD/CAM customized glass fiber post and core after applying different surface treatment techniques. Forty premolars were prepared to receive a customized CAD/CAM glass-fiber post and core obtained from an experimental block of glass fiber and epoxy resin. The specimens were randomly distributed in 4 groups (n=10) according to the post and core surface treatment: ETH - 70% ethanol; HP - 24% hydrogen peroxide for 1 minute; ETH/S - 70% ethanol + silane; HP/S - 24% hydrogen peroxide + silane. The universal adhesive containing silane was applied on the posts and prepared post spaces in all groups. The posts were cemented using dual cure resin cement. The specimens were stored in distilled water at 37°C for 24 h, cut (two slices of 1 mm for each root third - coronal, middle, and apical) and subjected to push-out test (0.5 mm/min). Data was subjected to two-way ANOVA (surface treatment and root third) and Tukey's test (α=0,05). There was no significant difference of bond strength values among groups, regardless the surface treatment ( p >0.05). There was significant difference on bond strength values for the different root thirds ( p <0.05) (coronal>middle=apical). The different surface treatment and application of additional silane in the CAD/CAM customized glass-fiber post and core does not interfere on bond strength values. The root dentin third interfered on the bond strength, with higher values for the coronal third. Key words: Post and core technique, cad/cam, shear strength, hydrogen peroxide.
Wallace, Robert B; Wactawski-Wende, Jean; O'Sullivan, Mary Jo; Larson, Joseph C; Cochrane, Barbara; Gass, Margery; Masaki, Kamal
2011-01-01
Background: The Women's Health Initiative (WHI) randomized clinical trial (RCT) of calcium plus vitamin D (CaD) supplements found a 17% excess in urinary tract stone incidence in the supplemented group. This study evaluated whether this risk is modified by participant characteristics. Objective: We examined the correlates of urinary tract stone occurrence in the CaD arm of the WHI trial. Design: We analyzed an RCT involving 36,282 postmenopausal women aged 50–79 y from 40 WHI centers: 18,176 women received 500 mg calcium carbonate plus 200 IU vitamin D3 twice daily (1000 mg and 400 IU daily, respectively), and 18,106 women received a matching placebo for an average of 7.0 y. The incidence of urinary tract stones was determined. Results: The incidence of self-reported clinically diagnosed urinary tract stones was more common in the active CaD medication group than in the placebo group (hazard ratio: 1.17; 95% CI: 1.02, 1.34): 449 women in the CaD group and 381 women in the placebo group reported a stone during the trial. The rates of self-reported stones did not differ between various demographic, anthropomorphic, dietary, and other hypothesized risk factors according to randomization assignment. Neither the total calcium intake nor the use of calcium supplements at baseline was associated with the risk of stones. In sensitivity analyses that censored participants who were below 80% adherence, the findings were similar. Conclusions: Daily supplementation with CaD for 7 y was associated with an increase in the number of self-reported urinary tract stones. These findings have implications for CaD supplement use. This trial was registered with the WHI at clinicaltrials.gov as NCT00000611. PMID:21525191
CT versus MR Techniques in the Detection of Cervical Artery Dissection.
Hanning, Uta; Sporns, Peter B; Schmiedel, Meilin; Ringelstein, Erich B; Heindel, Walter; Wiendl, Heinz; Niederstadt, Thomas; Dittrich, Ralf
2017-11-01
Spontaneous cervical artery dissection (sCAD) is an important etiology of juvenile stroke. The gold standard for the diagnosis of sCAD is convential angiography. However, magnetic resonance imaging (MRI)/MR angiography (MRA) and computed tomography (CT)/CT angiography (CTA) are frequently used alternatives. New developments such as multislice CT/CTA have enabled routine acquisition of thinner sections with rapid imaging times. The goal of this study was to compare the capability of recent developed 128-slice CT/CTA to MRI/MRA to detect radiologic features of sCAD. Retrospective review of patients with suspected sCAD (n = 188) in a database of our Stroke center (2008-2014), who underwent CT/CTA and MRI/MRA on initial clinical work-up. A control group of 26 patients was added. All Images were evaluated concerning specific and sensitive radiological features for dissection by two experienced neuroradiologists. Imaging features were compared between the two modalities. Forty patients with 43 dissected arteries received both modalities (29 internal carotid arteries [ICAs] and 14 vertebral arteries [VAs]). All CADs were identified in CT/CTA and MRI/MRA. The features intimal flap, stenosis, and lumen irregularity appeared in both modalities. One high-grade stenosis was identified by CT/CTA that was expected occluded on MRI/MRA. Two MRI/MRA-confirmed pseudoaneurysms were missed by CT/CTA. None of the controls evidenced specific imaging signs for dissection. CT/CTA is a reliable and better available alternative to MRI/MRA for diagnosis of sCAD. CT/CTA should be used to complement MRI/MRA in cases where MRI/MRA suggests occlusion. Copyright © 2017 by the American Society of Neuroimaging.
Ozawa, Daisuke; Suzuki, Yasunori; Kawamura, Noboru; Ohkubo, Chikahiro
2015-04-01
A crown restoration engaged by a clasp as an abutment tooth for a removable partial denture (RPD) occasionally might be removed and eliminated due to secondary caries or apical lesions. However, if the RPD is clinically acceptable without any problems and refabricating the RPD is not recommended, the new crown must be made to retrofit to the existing clasp of the RPD. This in vitro study evaluated the conventional and CAD/CAM procedures for retrofitting crown restorations to the existing clasps by measuring the fitness accuracy and the retentive forces. The crown restoration on #44 was fabricated with CP titanium and zirconium on the plaster model with #45 and #46 teeth missing to retrofit to the existing clasp using conventional thin coping and CAD/CAM procedures. The gap distance between the clasp (tip, shoulder, and rest regions) and the fabricated crown was measured using silicone impression material. The retentive force of the clasp was also measured, using an autograph at a crosshead speed of 50mm/min. The obtained data were analyzed by one-way ANOVA/Tukey's multiple comparison test (α=0.05). The CAD/CAM procedure caused significantly smaller gap distances in all of the clasp regions, as compared to the conventional procedure (p<0.05). The retentive force of the CAD/CAM crown was significantly higher than for the conventional one (p<0.05). When a crown restoration must be remade to retrofit an existing clasp, CAD/CAM fabrication can be recommended so that both appropriate fitness and retentive force are obtained. Copyright © 2015 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
Tekçe, Neslihan; Tuncer, Safa; Demirci, Mustafa; Kara, Dilan; Baydemir, Canan
2018-02-11
To investigate the effect of sandblasting powder particles on microtensile bond strength (μTBS) of dual-cure adhesive cement to CAD/CAM blocks. CAD/CAM blocks (Cerasmart, VITA, and LAVA) were cut in slabs and divided into groups: group 1, no sandblasting; group 2, sandblasted with 27-μm Al 2 O 3 ; group 3, sandblasted with 30-μm CoJet; group 4, sandblasted with 50-μm Al 2 O 3 . After sandblasting, all specimens were silanized and luted using dual-cure adhesive cement (G-CEM LinkForce). After 24 hours, bonded specimens were cut into 1 ± 0.2 mm 2 sticks, and μTBS values were obtained (N = 30). Additionally, 132 CAD/CAM block sections were prepared for surface roughness testing and scanning electron microscopy (SEM) evaluations. Results were analyzed using Kruskal-Wallis One-way ANOVA and Dunn's Post Hoc Test (p < 0.05). Group 1 exhibited significantly lower μTBS than the other groups (p < 0.05). The highest bond strength values were obtained from group 4 (p > 0.05). For LAVA, μTBS values of specimens that were sandblasted with 50-μm Al 2 O 3 powder were significantly higher than 30-μm-SiO 2 and 27-μm Al 2 O 3 (p < 0.05). The sand particles investigated (27-μm Al 2 O 3 , 30-μm SiO 2 , or 50-μm Al 2 O 3 ) did not significantly affect μTBS results of CAD/CAM blocks for Cerasmart and VITA, although the results changed significantly for LAVA. The ideal bond protocol for CAD/CAM blocks is specific to the material used. © 2018 by the American College of Prosthodontists.
Grohmann, Philipp; Bindl, Andreas; Hämmerle, Christoph; Mehl, Albert; Sailer, Irena
2015-01-01
The aim of this multicenter randomized controlled clinical trial was to test posterior zirconia-ceramic fixed dental prostheses (FDPs) veneered with a computer-aided design/computer- assisted manufacture (CAD/CAM) lithium disilicate veneering ceramic (CAD-on) and manually layered zirconia veneering ceramic with respect to survival of the FDPs, and technical and biologic outcomes. Sixty patients in need of one posterior three-unit FDP were included. The zirconia frameworks were produced with a CAD/CAM system (Cerec inLab 3D/Cerec inEOS inLab). Thirty FDPs were veneered with a CAD/CAM lithium disilicate veneering ceramic (Cad-on) (test) and 30 were veneered with a layered zirconia veneering ceramic (control). For the clinical evaluation at baseline, 6, and 12 months, the United States Public Health Service (USPHS) criteria were used. The biologic outcome was judged by comparing the plaque control record (PCR), bleeding on probing (BOP), and probing pocket depth (PPD). Data were statistically analyzed. Fifty-six patients were examined at a mean follow-up of 13.9 months. At the 1-year follow-up the survival rate was 100% in the test and in the control group. No significant differences of the technical outcomes occurred. Major chipping occurred in the control group (n = 3) and predominantly minor chipping in the test group (minor n = 2, major n = 1). No biologic problems or differences were found. Both types of zirconia-ceramic FDPs exhibited very good clinical outcomes without differences between groups. Chipping occurred in both types of FDPs at small amounts, yet the extension of the chippings differed. The test FDPs predominantly exhibited minor chipping, the control FDPs major chipping.
Tamburus, Nayara Y; Paula, Roberta F L; Kunz, Vandeni C; César, Marcelo C; Moreno, Marlene A; da Silva, Ester
2015-01-01
Autonomic dysfunction and inflammatory activity are involved in the development and progression of coronary artery disease (CAD), and exercise training has been shown to confer a cardiovascular benefit. To evaluate the effects that interval training (IT) based on ventilatory anaerobic threshold (VAT) has on heart rate variability (HRV) and high-sensitivity C-reactive protein (hs-CRP) levels, as well as the relationship between both levels, in patients with CAD and/or cardiovascular risk factors (RF). Forty-two men (aged 57.88±6.20 years) were divided into two training groups, CAD-T (n= 12) and RF-T (n= 10), and two control groups, CAD-C (n= 10) and RF-C (n=10). Heart rate and RR intervals in the supine position, cardiopulmonary exercise tests, and hs-CRP levels were measured before and after IT. HRV was analyzed by spectral and symbolic analysis. The CAD-T and RF-T underwent a 16-week IT program of three weekly sessions at training intensities based on the VAT. In the RF-T, cardiac sympathetic modulation index and hs-CRP decreased (p<0.02), while cardiac parasympathetic modulation index increased (p<0.02). In the CAD-T, cardiac parasympathetic modulation index increased, while hs-CRP, systolic, and diastolic blood pressures decreased (p<0.02). Both control groups showed increase in hs-CRP parameters (p<0.02). There was a strong and significant association between parasympathetic and sympathetic modulations with hs-CRP. The IT program based on the VAT promoted a decrease in hs-CRP associated with improvement in cardiac autonomic modulation.
Detection of Anomalous Insiders in Collaborative Environments via Relational Analysis of Access Logs
Chen, You; Malin, Bradley
2014-01-01
Collaborative information systems (CIS) are deployed within a diverse array of environments, ranging from the Internet to intelligence agencies to healthcare. It is increasingly the case that such systems are applied to manage sensitive information, making them targets for malicious insiders. While sophisticated security mechanisms have been developed to detect insider threats in various file systems, they are neither designed to model nor to monitor collaborative environments in which users function in dynamic teams with complex behavior. In this paper, we introduce a community-based anomaly detection system (CADS), an unsupervised learning framework to detect insider threats based on information recorded in the access logs of collaborative environments. CADS is based on the observation that typical users tend to form community structures, such that users with low a nity to such communities are indicative of anomalous and potentially illicit behavior. The model consists of two primary components: relational pattern extraction and anomaly detection. For relational pattern extraction, CADS infers community structures from CIS access logs, and subsequently derives communities, which serve as the CADS pattern core. CADS then uses a formal statistical model to measure the deviation of users from the inferred communities to predict which users are anomalies. To empirically evaluate the threat detection model, we perform an analysis with six months of access logs from a real electronic health record system in a large medical center, as well as a publicly-available dataset for replication purposes. The results illustrate that CADS can distinguish simulated anomalous users in the context of real user behavior with a high degree of certainty and with significant performance gains in comparison to several competing anomaly detection models. PMID:25485309
Ko, Dennis T; Tu, Jack V; Austin, Peter C; Wijeysundera, Harindra C; Samadashvili, Zaza; Guo, Helen; Cantor, Warren J; Hannan, Edward L
2013-07-10
Prior studies have shown that physicians in New York State (New York) perform twice as many cardiac catheterizations per capita as those in Ontario for stable patients. However, the role of patient selection in these findings and their implications for detection of obstructive coronary artery disease (CAD) are largely unknown. To evaluate the extent of obstructive CAD and to compare the probability of detecting obstructive CAD for patients undergoing cardiac catheterization. An observational study was conducted involving patients without a history of cardiac disease who underwent elective cardiac catheterization between October 1, 2008, and September 30, 2011. Obstructive CAD was defined as diameter stenosis of 50% or more in the left main coronary artery or stenosis of 70% or more in a major epicardial vessel. Observed rates and predicted probabilities of obstructive CAD. Predicted probabilities were estimated using logistic regression models. A total of 18,114 patients from New York and 54,933 from Ontario were included. The observed rate of obstructive CAD was significantly lower in New York at 30.4% (95% CI, 29.7%-31.0%) than in Ontario at 44.8% (95% CI, 44.4%-45.3%; P < .001). The percentage of patients with left main or 3-vessel CAD was also significantly lower in New York than in Ontario (7.0% [95% CI, 6.6%-7.3%] vs 13.0% [95% CI, 12.8%-13.3%]; P < .001). In New York, a substantially higher percentage of patients with low predicted probability of obstructive CAD underwent cardiac catheterization; for example, only 19.3% (95% CI, 18.7%-19.9%) of patients undergoing cardiac catheterization in New York had a greater than 50% predicted probability of having obstructive CAD than those in Ontario at 41% (95% CI, 40.6%-41.4%; P < .001). At 30 days, crude mortality for patients undergoing cardiac catheterization was slightly higher in New York at 0.65% (90 of 13,824; 95% CI, 0.51%-0.78%) than in Ontario at 0.38% (153 of 40,794; 95% CI, 0.32%-0.43%; P < .001). In Ontario compared with New York State, patients undergoing elective cardiac catheterization were significantly more likely to have obstructive CAD. This appears to be related to a higher percentage of patients in New York with low predicted probability of CAD undergoing cardiac catheterization.
Kwon, Sung Woo; Kim, Young Jin; Shim, Jaemin; Sung, Ji Min; Han, Mi Eun; Kang, Dong Won; Kim, Ji-Ye; Choi, Byoung Wook; Chang, Hyuk-Jae
2011-04-01
To evaluate the prognostic outcome of cardiac computed tomography (CT) for prediction of major adverse cardiac events (MACEs) in low-risk patients suspected of having coronary artery disease (CAD) and to explore the differential prognostic values of coronary artery calcium (CAC) scoring and coronary CT angiography. Institutional review committee approval and informed consent were obtained. In 4338 patients who underwent 64-section CT for evaluation of suspected CAD, both CAC scoring and CT angiography were concurrently performed by using standard scanning protocols. Follow-up clinical outcome data regarding composite MACEs were procured. Multivariable Cox proportional hazards models were developed to predict MACEs. Risk-adjusted models incorporated traditional risk factors for CAC scoring and coronary CT angiography. During the mean follow-up of 828 days ± 380, there were 105 MACEs, for an event rate of 3%. The presence of obstructive CAD at coronary CT angiography had independent prognostic value, which escalated according to the number of stenosed vessels (P < .001). In the receiver operating characteristic curve (ROC) analysis, the superiority of coronary CT angiography to CAC scoring was demonstrated by a significantly greater area under the ROC curve (AUC) (0.892 vs 0.810, P < .001), whereas no significant incremental value for the addition of CAC scoring to coronary CT angiography was established (AUC = 0.892 for coronary CT angiography alone vs 0.902 with addition of CAC scoring, P = .198). Coronary CT angiography is better than CAC scoring in predicting MACEs in low-risk patients suspected of having CAD. Furthermore, the current standard multisection CT protocol (coronary CT angiography combined with CAC scoring) has no incremental prognostic value compared with coronary CT angiography alone. Therefore, in terms of determining prognosis, CAC scoring may no longer need to be incorporated in the cardiac CT protocol in this population. © RSNA, 2011.
Chevalier, Laurent; Kervio, Gaelle; Doutreleau, Stephane; Mathieu, Jean-Philippe; Guy, Jean-Michel; Mignot, Aude; Corneloup, Luc; Passard, François; Laporte, Thierry; Girard-Girod, Aude; Hennebert, Olivier; Bernadet, Philippe; Vincent-Chevalier, Marie-Pierre; Gencel, Laurent; Carré, François
2017-03-01
Cardiovascular events related to high-intensity sport practice are rare but dramatic. Coronary artery disease (CAD) is the leading cause of these events after the age of 35 years. The value of a maximal exercise test (ET) for detection of athletes at risk remains a matter of debate. The aim of this prospective multicentre study was to clarify the medical value and cost-effectiveness of an ET in middle-aged white asymptomatic athletes who participate in high-intensity sport. All athletes had a physical examination, assessment of cardiovascular risk factors, a resting electrocardiogram and an ET. In case of abnormal ET, complementary cardiovascular evaluation was performed, when requested, to detect potential cardiovascular disease. 1361 asymptomatic athletes (mean age 50.4±9.6 years; mean training 5.1±3.2h/week; 10.4% women) with a normal resting electrocardiogram and without cardiovascular disease were consecutively included. An abnormal ET was reported in 144 subjects (94% men); this was positively related to the subject's age and cardiovascular risk level. Cardiac arrhythmias (48%) and CAD symptoms (33.3%) were mainly reported. Cardiovascular disease was confirmed in 24 cases (1.7% from the whole population; 16.7% from those with an abnormal ET) - mainly CAD (n=12) and arterial hypertension (n=8). Seventy athletes presented significant unexplained arrhythmias. The cost was approximately €8450 for every confirmed case of cardiovascular disease. In this multicentre study in middle-aged athletes, a systematic ET was abnormal in 10.6% of cases. About 2% of subjects had cardiovascular disease, mainly arrhythmias and CAD. From these results, it seems that in a trained population aged >35 years, ET should be targeted at men with at least two cardiovascular risk factors, with acceptable cost-effectiveness. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Yin, Xinxin; Zheng, Wen; Ma, Jingjing; Hao, Panpan
2016-01-01
Background Both coronary computed tomography angiography (CCTA) and exercise electrocardiography (ExECG) are non-invasive testing methods for the evaluation of coronary artery disease (CAD). However, there was controversy on the diagnostic performance of these methods due to the limited data in each single study. Therefore, we performed a meta-analysis to address these issues. Methods We searched PubMed and Embase databases up to May 22, 2015. Two authors identified eligible studies, extracted data and accessed quality. Pooled estimation of sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), summary receiver-operating characteristic curve (SROC) and the area under curve (AUC) of CCTA and ExECG for the diagnosis of CAD were calculated using Stata, Meta-Disc and Review Manager statistical software. Results Seven articles were included. Pooled sensitivity of CCTA and ExECG were 0.98 [95% confidence intervals (CIs): 0.95–0.99] and 0.66 (95% CIs: 0.59–0.72); pooled specificity of CCTA and ExECG were 0.84 (95% CIs: 0.81–0.87) and 0.75 (95% CIs: 0.71–0.79); pooled DOR of CCTA and ExECG were 110.24 (95% CIs: 35.07–346.55) and 6.28 (95% CIs: 2.06–19.13); and AUC of CCTA and ExECG were 0.9950±0.0046 and 0.7727±0.0638, respectively. There is no heterogeneity caused by threshold effect in CCTA or ExECG analysis. The Deeks’ test showed no potential publication bias (P=0.17). Conclusions CCTA has better diagnostic performance than ExECG in the evaluation of CAD, which can provide a better solution for the clinical problem of the diagnosis for CAD. PMID:27499958
Xiu, Jiancheng; Cui, Kai; Wang, Yuegang; Zheng, Hua; Chen, Gangbin; Feng, Qian; Bin, Jianping; Wu, Juefei; Porter, Thomas R
2017-03-01
Myocardial perfusion (MP) imaging during stress myocardial contrast echocardiography (MCE) improves the detection of coronary artery disease (CAD). However, its prognostic value to predict cardiac events in patients with known or suspected CAD is still undefined. A search was conducted for single- or multicenter prospective studies that evaluated the prognostic value of stress MCE in patients with known or suspected CAD. A database search was performed through June 2015. Effect sizes of relative risk ratios (RRs) with their corresponding 95% CIs were used to evaluate the association between the occurrence of total cardiac events (cardiac death, nonfatal myocardial infarction, coronary revascularization) and hard cardiac events (cardiac death and nonfatal myocardial infarction) in subjects with normal and abnormal MP measured by MCE. The Cochran Q statistic and the I 2 statistic were used to assess heterogeneity. A comprehensive literature search of the MEDLINE, Google Scholar, Cochrane, and Embase databases identified 11 studies enrolling a total of 4,045 patients. The overall analysis of RRs revealed that patients with abnormal MP were at higher risk for total cardiac events compared with patients with normal MP (RR, 5.58; 95% CI, 3.64-8.57; P < .001), with low heterogeneity among trials (I 2 = 48.15%, Q = 7.71, P = .103). Similarly, patients with abnormal MP were at higher risk for hard cardiac events compared with patients with normal MP (RR, 4.99; 95% CI, 1.75-14.32; P = .003), with significant heterogeneity among trials (I 2 = 81.48%, Q = 21.59, P < .001). The results of this meta-analysis suggest that MP assessment using stress MCE is an effective prognostic tool for predicting the occurrence of cardiac events in patients with known or suspected CAD. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.