TGeoCad: an Interface between ROOT and CAD Systems
NASA Astrophysics Data System (ADS)
Luzzi, C.; Carminati, F.
2014-06-01
In the simulation of High Energy Physics experiment a very high precision in the description of the detector geometry is essential to achieve the required performances. The physicists in charge of Monte Carlo Simulation of the detector need to collaborate efficiently with the engineers working at the mechanical design of the detector. Often, this collaboration is made hard by the usage of different and incompatible software. ROOT is an object-oriented C++ framework used by physicists for storing, analyzing and simulating data produced by the high-energy physics experiments while CAD (Computer-Aided Design) software is used for mechanical design in the engineering field. The necessity to improve the level of communication between physicists and engineers led to the implementation of an interface between the ROOT geometrical modeler used by the virtual Monte Carlo simulation software and the CAD systems. In this paper we describe the design and implementation of the TGeoCad Interface that has been developed to enable the use of ROOT geometrical models in several CAD systems. To achieve this goal, the ROOT geometry description is converted into STEP file format (ISO 10303), which can be imported and used by many CAD systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Masotti, Matteo; Lanconelli, Nico; Campanini, Renato
In this work, gray-scale invariant ranklet texture features are proposed for false positive reduction (FPR) in computer-aided detection (CAD) of breast masses. Two main considerations are at the basis of this proposal. First, false positive (FP) marks surviving our previous CAD system seem to be characterized by specific texture properties that can be used to discriminate them from masses. Second, our previous CAD system achieves invariance to linear/nonlinear monotonic gray-scale transformations by encoding regions of interest into ranklet images through the ranklet transform, an image transformation similar to the wavelet transform, yet dealing with pixels' ranks rather than with theirmore » gray-scale values. Therefore, the new FPR approach proposed herein defines a set of texture features which are calculated directly from the ranklet images corresponding to the regions of interest surviving our previous CAD system, hence, ranklet texture features; then, a support vector machine (SVM) classifier is used for discrimination. As a result of this approach, texture-based information is used to discriminate FP marks surviving our previous CAD system; at the same time, invariance to linear/nonlinear monotonic gray-scale transformations of the new CAD system is guaranteed, as ranklet texture features are calculated from ranklet images that have this property themselves by construction. To emphasize the gray-scale invariance of both the previous and new CAD systems, training and testing are carried out without any in-between parameters' adjustment on mammograms having different gray-scale dynamics; in particular, training is carried out on analog digitized mammograms taken from a publicly available digital database, whereas testing is performed on full-field digital mammograms taken from an in-house database. Free-response receiver operating characteristic (FROC) curve analysis of the two CAD systems demonstrates that the new approach achieves a higher reduction of FP marks when compared to the previous one. Specifically, at 60%, 65%, and 70% per-mammogram sensitivity, the new CAD system achieves 0.50, 0.68, and 0.92 FP marks per mammogram, whereas at 70%, 75%, and 80% per-case sensitivity it achieves 0.37, 0.48, and 0.71 FP marks per mammogram, respectively. Conversely, at the same sensitivities, the previous CAD system reached 0.71, 0.87, and 1.15 FP marks per mammogram, and 0.57, 0.73, and 0.92 FPs per mammogram. Also, statistical significance of the difference between the two per-mammogram and per-case FROC curves is demonstrated by the p-value<0.001 returned by jackknife FROC analysis performed on the two CAD systems.« less
A review of intelligent systems for heart sound signal analysis.
Nabih-Ali, Mohammed; El-Dahshan, El-Sayed A; Yahia, Ashraf S
2017-10-01
Intelligent computer-aided diagnosis (CAD) systems can enhance the diagnostic capabilities of physicians and reduce the time required for accurate diagnosis. CAD systems could provide physicians with a suggestion about the diagnostic of heart diseases. The objective of this paper is to review the recent published preprocessing, feature extraction and classification techniques and their state of the art of phonocardiogram (PCG) signal analysis. Published literature reviewed in this paper shows the potential of machine learning techniques as a design tool in PCG CAD systems and reveals that the CAD systems for PCG signal analysis are still an open problem. Related studies are compared to their datasets, feature extraction techniques and the classifiers they used. Current achievements and limitations in developing CAD systems for PCG signal analysis using machine learning techniques are presented and discussed. In the light of this review, a number of future research directions for PCG signal analysis are provided.
Understanding dental CAD/CAM for restorations--accuracy from a mechanical engineering viewpoint.
Tapie, Laurent; Lebon, Nicolas; Mawussi, Bernardin; Fron-Chabouis, Hélène; Duret, Francois; Attal, Jean-Pierre
2015-01-01
As is the case in the field of medicine, as well as in most areas of daily life, digital technology is increasingly being introduced into dental practice. Computer-aided design/ computer-aided manufacturing (CAD/CAM) solutions are available not only for chairside practice but also for creating inlays, crowns, fixed partial dentures (FPDs), implant abutments, and other dental prostheses. CAD/CAM dental practice can be considered as the handling of devices and software processing for the almost automatic design and creation of dental restorations. However, dentists who want to use dental CAD/CAM systems often do not have enough information to understand the variations offered by such technology practice. Knowledge of the random and systematic errors in accuracy with CAD/CAM systems can help to achieve successful restorations with this technology, and help with the purchasing of a CAD/CAM system that meets the clinical needs of restoration. This article provides a mechanical engineering viewpoint of the accuracy of CAD/ CAM systems, to help dentists understand the impact of this technology on restoration accuracy.
NASA Astrophysics Data System (ADS)
Chen, Shaobin; Zhang, Xubo; Wang, Wenyuan; Zhou, Chengping; Ding, Mingyue
2007-11-01
Nowadays many Geographic Information System (GIS) have been widely used in many municipal corporations. Water-supplying corporations in many cities developed GIS application system based on SiCAD/Open GIS platform several years ago for their daily management and engineering construction. With the increasing of commercial business, many corporations now need to add the functionality of three dimensional to display to their GIS System without too much financial cost. Because of the expensiveness of updating SiCAD/Open GIS system to the up-to-date version, the introduction of a third-part 3D display technology is considered. In our solution, Visualization Toolkit (VTK) is used to achieve three dimensional display of underground water-supplying network on the basis of an existing SiCAD/Open GIS system. This paper addresses on the system architecture and key implementation technologies of this solution.
Increasing productivity of the McAuto CAD/CAE system by user-specific applications programming
NASA Technical Reports Server (NTRS)
Plotrowski, S. M.; Vu, T. H.
1985-01-01
Significant improvements in the productivity of the McAuto Computer-Aided Design/Computer-Aided Engineering (CAD/CAE) system were achieved by applications programming using the system's own Graphics Interactive Programming language (GRIP) and the interface capabilities with the main computer on which the system resides. The GRIP programs for creating springs, bar charts, finite element model representations and aiding management planning are presented as examples.
Computer aided detection of surgical retained foreign object for prevention
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hadjiiski, Lubomir, E-mail: lhadjisk@umich.edu; Marentis, Theodore C.; Rondon, Lucas
2015-03-15
Purpose: Surgical retained foreign objects (RFOs) have significant morbidity and mortality. They are associated with approximately $1.5 × 10{sup 9} annually in preventable medical costs. The detection accuracy of radiographs for RFOs is a mediocre 59%. The authors address the RFO problem with two complementary technologies: a three-dimensional (3D) gossypiboma micro tag, the μTag that improves the visibility of RFOs on radiographs, and a computer aided detection (CAD) system that detects the μTag. It is desirable for the CAD system to operate in a high specificity mode in the operating room (OR) and function as a first reader for themore » surgeon. This allows for fast point of care results and seamless workflow integration. The CAD system can also operate in a high sensitivity mode as a second reader for the radiologist to ensure the highest possible detection accuracy. Methods: The 3D geometry of the μTag produces a similar two dimensional (2D) depiction on radiographs regardless of its orientation in the human body and ensures accurate detection by a radiologist and the CAD. The authors created a data set of 1800 cadaver images with the 3D μTag and other common man-made surgical objects positioned randomly. A total of 1061 cadaver images contained a single μTag and the remaining 739 were without μTag. A radiologist marked the location of the μTag using an in-house developed graphical user interface. The data set was partitioned into three independent subsets: a training set, a validation set, and a test set, consisting of 540, 560, and 700 images, respectively. A CAD system with modules that included preprocessing μTag enhancement, labeling, segmentation, feature analysis, classification, and detection was developed. The CAD system was developed using the training and the validation sets. Results: On the training set, the CAD achieved 81.5% sensitivity with 0.014 false positives (FPs) per image in a high specificity mode for the surgeons in the OR and 96.1% sensitivity with 0.81 FPs per image in a high sensitivity mode for the radiologists. On the independent test set, the CAD achieved 79.5% sensitivity with 0.003 FPs per image in a high specificity mode for the surgeons and 90.2% sensitivity with 0.23 FPs per image in a high sensitivity mode for the radiologists. Conclusions: To the best of the authors’ knowledge, this is the first time a 3D μTag is used to produce a recognizable, substantially similar 2D projection on radiographs regardless of orientation in space. It is the first time a CAD system is used to search for man-made objects over anatomic background. The CAD system for the μTags achieved reasonable performance in both the high specificity and the high sensitivity modes.« less
A computer-aided detection (CAD) system with a 3D algorithm for small acute intracranial hemorrhage
NASA Astrophysics Data System (ADS)
Wang, Ximing; Fernandez, James; Deshpande, Ruchi; Lee, Joon K.; Chan, Tao; Liu, Brent
2012-02-01
Acute Intracranial hemorrhage (AIH) requires urgent diagnosis in the emergency setting to mitigate eventual sequelae. However, experienced radiologists may not always be available to make a timely diagnosis. This is especially true for small AIH, defined as lesion smaller than 10 mm in size. A computer-aided detection (CAD) system for the detection of small AIH would facilitate timely diagnosis. A previously developed 2D algorithm shows high false positive rates in the evaluation based on LAC/USC cases, due to the limitation of setting up correct coordinate system for the knowledge-based classification system. To achieve a higher sensitivity and specificity, a new 3D algorithm is developed. The algorithm utilizes a top-hat transformation and dynamic threshold map to detect small AIH lesions. Several key structures of brain are detected and are used to set up a 3D anatomical coordinate system. A rule-based classification of the lesion detected is applied based on the anatomical coordinate system. For convenient evaluation in clinical environment, the CAD module is integrated with a stand-alone system. The CAD is evaluated by small AIH cases and matched normal collected in LAC/USC. The result of 3D CAD and the previous 2D CAD has been compared.
Computer-Aided Diagnosis Systems for Lung Cancer: Challenges and Methodologies
El-Baz, Ayman; Beache, Garth M.; Gimel'farb, Georgy; Suzuki, Kenji; Okada, Kazunori; Elnakib, Ahmed; Soliman, Ahmed; Abdollahi, Behnoush
2013-01-01
This paper overviews one of the most important, interesting, and challenging problems in oncology, the problem of lung cancer diagnosis. Developing an effective computer-aided diagnosis (CAD) system for lung cancer is of great clinical importance and can increase the patient's chance of survival. For this reason, CAD systems for lung cancer have been investigated in a huge number of research studies. A typical CAD system for lung cancer diagnosis is composed of four main processing steps: segmentation of the lung fields, detection of nodules inside the lung fields, segmentation of the detected nodules, and diagnosis of the nodules as benign or malignant. This paper overviews the current state-of-the-art techniques that have been developed to implement each of these CAD processing steps. For each technique, various aspects of technical issues, implemented methodologies, training and testing databases, and validation methods, as well as achieved performances, are described. In addition, the paper addresses several challenges that researchers face in each implementation step and outlines the strengths and drawbacks of the existing approaches for lung cancer CAD systems. PMID:23431282
Mass classification in mammography with multi-agent based fusion of human and machine intelligence
NASA Astrophysics Data System (ADS)
Xi, Dongdong; Fan, Ming; Li, Lihua; Zhang, Juan; Shan, Yanna; Dai, Gang; Zheng, Bin
2016-03-01
Although the computer-aided diagnosis (CAD) system can be applied for classifying the breast masses, the effects of this method on improvement of the radiologist' accuracy for distinguishing malignant from benign lesions still remain unclear. This study provided a novel method to classify breast masses by integrating the intelligence of human and machine. In this research, 224 breast masses were selected in mammography from database of DDSM with Breast Imaging Reporting and Data System (BI-RADS) categories. Three observers (a senior and a junior radiologist, as well as a radiology resident) were employed to independently read and classify these masses utilizing the Positive Predictive Values (PPV) for each BI-RADS category. Meanwhile, a CAD system was also implemented for classification of these breast masses between malignant and benign. To combine the decisions from the radiologists and CAD, the fusion method of the Multi-Agent was provided. Significant improvements are observed for the fusion system over solely radiologist or CAD. The area under the receiver operating characteristic curve (AUC) of the fusion system increased by 9.6%, 10.3% and 21% compared to that of radiologists with senior, junior and resident level, respectively. In addition, the AUC of this method based on the fusion of each radiologist and CAD are 3.5%, 3.6% and 3.3% higher than that of CAD alone. Finally, the fusion of the three radiologists with CAD achieved AUC value of 0.957, which was 5.6% larger compared to CAD. Our results indicated that the proposed fusion method has better performance than radiologist or CAD alone.
Integrating CAD modules in a PACS environment using a wide computing infrastructure.
Suárez-Cuenca, Jorge J; Tilve, Amara; López, Ricardo; Ferro, Gonzalo; Quiles, Javier; Souto, Miguel
2017-04-01
The aim of this paper is to describe a project designed to achieve a total integration of different CAD algorithms into the PACS environment by using a wide computing infrastructure. The aim is to build a system for the entire region of Galicia, Spain, to make CAD accessible to multiple hospitals by employing different PACSs and clinical workstations. The new CAD model seeks to connect different devices (CAD systems, acquisition modalities, workstations and PACS) by means of networking based on a platform that will offer different CAD services. This paper describes some aspects related to the health services of the region where the project was developed, CAD algorithms that were either employed or selected for inclusion in the project, and several technical aspects and results. We have built a standard-based platform with which users can request a CAD service and receive the results in their local PACS. The process runs through a web interface that allows sending data to the different CAD services. A DICOM SR object is received with the results of the algorithms stored inside the original study in the proper folder with the original images. As a result, a homogeneous service to the different hospitals of the region will be offered. End users will benefit from a homogeneous workflow and a standardised integration model to request and obtain results from CAD systems in any modality, not dependant on commercial integration models. This new solution will foster the deployment of these technologies in the entire region of Galicia.
Misawa, Masashi; Kudo, Shin-Ei; Mori, Yuichi; Takeda, Kenichi; Maeda, Yasuharu; Kataoka, Shinichi; Nakamura, Hiroki; Kudo, Toyoki; Wakamura, Kunihiko; Hayashi, Takemasa; Katagiri, Atsushi; Baba, Toshiyuki; Ishida, Fumio; Inoue, Haruhiro; Nimura, Yukitaka; Oda, Msahiro; Mori, Kensaku
2017-05-01
Real-time characterization of colorectal lesions during colonoscopy is important for reducing medical costs, given that the need for a pathological diagnosis can be omitted if the accuracy of the diagnostic modality is sufficiently high. However, it is sometimes difficult for community-based gastroenterologists to achieve the required level of diagnostic accuracy. In this regard, we developed a computer-aided diagnosis (CAD) system based on endocytoscopy (EC) to evaluate cellular, glandular, and vessel structure atypia in vivo. The purpose of this study was to compare the diagnostic ability and efficacy of this CAD system with the performances of human expert and trainee endoscopists. We developed a CAD system based on EC with narrow-band imaging that allowed microvascular evaluation without dye (ECV-CAD). The CAD algorithm was programmed based on texture analysis and provided a two-class diagnosis of neoplastic or non-neoplastic, with probabilities. We validated the diagnostic ability of the ECV-CAD system using 173 randomly selected EC images (49 non-neoplasms, 124 neoplasms). The images were evaluated by the CAD and by four expert endoscopists and three trainees. The diagnostic accuracies for distinguishing between neoplasms and non-neoplasms were calculated. ECV-CAD had higher overall diagnostic accuracy than trainees (87.8 vs 63.4%; [Formula: see text]), but similar to experts (87.8 vs 84.2%; [Formula: see text]). With regard to high-confidence cases, the overall accuracy of ECV-CAD was also higher than trainees (93.5 vs 71.7%; [Formula: see text]) and comparable to experts (93.5 vs 90.8%; [Formula: see text]). ECV-CAD showed better diagnostic accuracy than trainee endoscopists and was comparable to that of experts. ECV-CAD could thus be a powerful decision-making tool for less-experienced endoscopists.
Automated CAD design for sculptured airfoil surfaces
NASA Astrophysics Data System (ADS)
Murphy, S. D.; Yeagley, S. R.
1990-11-01
The design of tightly tolerated sculptured surfaces such as those for airfoils requires a significant design effort in order to machine the tools to create these surfaces. Because of the quantity of numerical data required to describe the airfoil surfaces, a CAD approach is required. Although this approach will result in productivity gains, much larger gains can be achieved by automating the design process. This paper discusses an application which resulted in an eightfold improvement in productivity by automating the design process on the CAD system.
Raghavendra, U; Gudigar, Anjan; Maithri, M; Gertych, Arkadiusz; Meiburger, Kristen M; Yeong, Chai Hong; Madla, Chakri; Kongmebhol, Pailin; Molinari, Filippo; Ng, Kwan Hoong; Acharya, U Rajendra
2018-04-01
Ultrasound imaging is one of the most common visualizing tools used by radiologists to identify the location of thyroid nodules. However, visual assessment of nodules is difficult and often affected by inter- and intra-observer variabilities. Thus, a computer-aided diagnosis (CAD) system can be helpful to cross-verify the severity of nodules. This paper proposes a new CAD system to characterize thyroid nodules using optimized multi-level elongated quinary patterns. In this study, higher order spectral (HOS) entropy features extracted from these patterns appropriately distinguished benign and malignant nodules under particle swarm optimization (PSO) and support vector machine (SVM) frameworks. Our CAD algorithm achieved a maximum accuracy of 97.71% and 97.01% in private and public datasets respectively. The evaluation of this CAD system on both private and public datasets confirmed its effectiveness as a secondary tool in assisting radiological findings. Copyright © 2018 Elsevier Ltd. All rights reserved.
Productivity increase through implementation of CAD/CAE workstation
NASA Technical Reports Server (NTRS)
Bromley, L. K.
1985-01-01
The tracking and communication division computer aided design/computer aided engineering system is now operational. The system is utilized in an effort to automate certain tasks that were previously performed manually. These tasks include detailed test configuration diagrams of systems under certification test in the ESTL, floorplan layouts of future planned laboratory reconfigurations, and other graphical documentation of division activities. The significant time savings achieved with this CAD/CAE system are examined: (1) input of drawings and diagrams; (2) editing of initial drawings; (3) accessibility of the data; and (4) added versatility. It is shown that the Applicon CAD/CAE system, with its ease of input and editing, the accessibility of data, and its added versatility, has made more efficient many of the necessary but often time-consuming tasks associated with engineering design and testing.
Liu, Z; Sun, J; Smith, M; Smith, L; Warr, R
2013-11-01
Computer-assisted diagnosis (CAD) of malignant melanoma (MM) has been advocated to help clinicians to achieve a more objective and reliable assessment. However, conventional CAD systems examine only the features extracted from digital photographs of lesions. Failure to incorporate patients' personal information constrains the applicability in clinical settings. To develop a new CAD system to improve the performance of automatic diagnosis of melanoma, which, for the first time, incorporates digital features of lesions with important patient metadata into a learning process. Thirty-two features were extracted from digital photographs to characterize skin lesions. Patients' personal information, such as age, gender and, lesion site, and their combinations, was quantified as metadata. The integration of digital features and metadata was realized through an extended Laplacian eigenmap, a dimensionality-reduction method grouping lesions with similar digital features and metadata into the same classes. The diagnosis reached 82.1% sensitivity and 86.1% specificity when only multidimensional digital features were used, but improved to 95.2% sensitivity and 91.0% specificity after metadata were incorporated appropriately. The proposed system achieves a level of sensitivity comparable with experienced dermatologists aided by conventional dermoscopes. This demonstrates the potential of our method for assisting clinicians in diagnosing melanoma, and the benefit it could provide to patients and hospitals by greatly reducing unnecessary excisions of benign naevi. This paper proposes an enhanced CAD system incorporating clinical metadata into the learning process for automatic classification of melanoma. Results demonstrate that the additional metadata and the mechanism to incorporate them are useful for improving CAD of melanoma. © 2013 British Association of Dermatologists.
Computer aided detection of clusters of microcalcifications on full field digital mammograms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ge Jun; Sahiner, Berkman; Hadjiiski, Lubomir M.
2006-08-15
We are developing a computer-aided detection (CAD) system to identify microcalcification clusters (MCCs) automatically on full field digital mammograms (FFDMs). The CAD system includes six stages: preprocessing; image enhancement; segmentation of microcalcification candidates; false positive (FP) reduction for individual microcalcifications; regional clustering; and FP reduction for clustered microcalcifications. At the stage of FP reduction for individual microcalcifications, a truncated sum-of-squares error function was used to improve the efficiency and robustness of the training of an artificial neural network in our CAD system for FFDMs. At the stage of FP reduction for clustered microcalcifications, morphological features and features derived from themore » artificial neural network outputs were extracted from each cluster. Stepwise linear discriminant analysis (LDA) was used to select the features. An LDA classifier was then used to differentiate clustered microcalcifications from FPs. A data set of 96 cases with 192 images was collected at the University of Michigan. This data set contained 96 MCCs, of which 28 clusters were proven by biopsy to be malignant and 68 were proven to be benign. The data set was separated into two independent data sets for training and testing of the CAD system in a cross-validation scheme. When one data set was used to train and validate the convolution neural network (CNN) in our CAD system, the other data set was used to evaluate the detection performance. With the use of a truncated error metric, the training of CNN could be accelerated and the classification performance was improved. The CNN in combination with an LDA classifier could substantially reduce FPs with a small tradeoff in sensitivity. By using the free-response receiver operating characteristic methodology, it was found that our CAD system can achieve a cluster-based sensitivity of 70, 80, and 90 % at 0.21, 0.61, and 1.49 FPs/image, respectively. For case-based performance evaluation, a sensitivity of 70, 80, and 90 % can be achieved at 0.07, 0.17, and 0.65 FPs/image, respectively. We also used a data set of 216 mammograms negative for clustered microcalcifications to further estimate the FP rate of our CAD system. The corresponding FP rates were 0.15, 0.31, and 0.86 FPs/image for cluster-based detection when negative mammograms were used for estimation of FP rates.« less
Web-based computer-aided-diagnosis (CAD) system for bone age assessment (BAA) of children
NASA Astrophysics Data System (ADS)
Zhang, Aifeng; Uyeda, Joshua; Tsao, Sinchai; Ma, Kevin; Vachon, Linda A.; Liu, Brent J.; Huang, H. K.
2008-03-01
Bone age assessment (BAA) of children is a clinical procedure frequently performed in pediatric radiology to evaluate the stage of skeletal maturation based on a left hand and wrist radiograph. The most commonly used standard: Greulich and Pyle (G&P) Hand Atlas was developed 50 years ago and exclusively based on Caucasian population. Moreover, inter- & intra-observer discrepancies using this method create a need of an objective and automatic BAA method. A digital hand atlas (DHA) has been collected with 1,400 hand images of normal children from Asian, African American, Caucasian and Hispanic descends. Based on DHA, a fully automatic, objective computer-aided-diagnosis (CAD) method was developed and it was adapted to specific population. To bring DHA and CAD method to the clinical environment as a useful tool in assisting radiologist to achieve higher accuracy in BAA, a web-based system with direct connection to a clinical site is designed as a novel clinical implementation approach for online and real time BAA. The core of the system, a CAD server receives the image from clinical site, processes it by the CAD method and finally, generates report. A web service publishes the results and radiologists at the clinical site can review it online within minutes. This prototype can be easily extended to multiple clinical sites and will provide the foundation for broader use of the CAD system for BAA.
Welter, Petra; Riesmeier, Jörg; Fischer, Benedikt; Grouls, Christoph; Kuhl, Christiane; Deserno, Thomas M
2011-01-01
It is widely accepted that content-based image retrieval (CBIR) can be extremely useful for computer-aided diagnosis (CAD). However, CBIR has not been established in clinical practice yet. As a widely unattended gap of integration, a unified data concept for CBIR-based CAD results and reporting is lacking. Picture archiving and communication systems and the workflow of radiologists must be considered for successful data integration to be achieved. We suggest that CBIR systems applied to CAD should integrate their results in a picture archiving and communication systems environment such as Digital Imaging and Communications in Medicine (DICOM) structured reporting documents. A sample DICOM structured reporting template adaptable to CBIR and an appropriate integration scheme is presented. The proposed CBIR data concept may foster the promulgation of CBIR systems in clinical environments and, thereby, improve the diagnostic process.
Riesmeier, Jörg; Fischer, Benedikt; Grouls, Christoph; Kuhl, Christiane; Deserno (né Lehmann), Thomas M
2011-01-01
It is widely accepted that content-based image retrieval (CBIR) can be extremely useful for computer-aided diagnosis (CAD). However, CBIR has not been established in clinical practice yet. As a widely unattended gap of integration, a unified data concept for CBIR-based CAD results and reporting is lacking. Picture archiving and communication systems and the workflow of radiologists must be considered for successful data integration to be achieved. We suggest that CBIR systems applied to CAD should integrate their results in a picture archiving and communication systems environment such as Digital Imaging and Communications in Medicine (DICOM) structured reporting documents. A sample DICOM structured reporting template adaptable to CBIR and an appropriate integration scheme is presented. The proposed CBIR data concept may foster the promulgation of CBIR systems in clinical environments and, thereby, improve the diagnostic process. PMID:21672913
Awad, Mohamed Moustafa; Alqahtani, H; Al-Mudahi, A; Murayshed, M S; Alrahlah, A; Bhandi, Shilpa H
2017-07-01
To review the adhesive bonding to different computer-aided design/computer-aided manufacturing (CAD/CAM) esthetic restorative materials. The use of CAD/CAM esthetic restorative materials has gained popularity in recent years. Several CAD/ CAM esthetic restorative materials are commercially available. Adhesive bonding is a major determinant of success of CAD/ CAM restorations. Review result: An account of the currently available bonding strategies are discussed with their rationale in various CAD/ CAM materials. Different surface treatment methods as well as adhesion promoters can be used to achieve reliable bonding of CAD/CAM restorative materials. Selection of bonding strategy to such material is determined based on its composition. Further evidence is required to evaluate the effect of new surface treatment methods, such as nonthermal atmospheric plasma and self-etching ceramic primer on bonding to different dental ceramics. An understanding of the currently available bonding strategies to CA/CAM materials can help the clinician to select the most indicated system for each category of materials.
Grenier, Jasmine; Leiter, Lawrence A; Langer, Anatoly; Goldin, Lianne; Teoh, Hwee; Connelly, Kim A; Cheng, Alice Y Y; Tan, Mary K; Fitchett, David; McGuire, Darren K; Goodman, Shaun G; Yan, Andrew T
2016-10-01
Current diabetes guidelines recommend an individualized approach to glycaemic control. There are limited data on the contemporary and comprehensive management of patients with diabetes in relation to coronary artery disease (CAD). The Diabetes Mellitus Status in Canada (DM-SCAN) survey included 5123 patients with type 2 diabetes seen in primary care in November 2012. Primary care physicians (PCPs) collected clinical data and specified the A1C target for each patient on standardized forms. We compared management strategies and achievement of treatment targets in patients with and without CAD. Among the 4994 patients with data on CAD history, 22.5% had CAD. Primary care physicians were more likely to select a higher A1C target for patients with CAD (≤7.5 or ≤8.0%) versus without (≤7.0%). There was no difference in median A1C or in the proportion of patients with A1C ≤7.0% between the two groups. Compared with the group without known CAD, patients with CAD had a higher reported prevalence of hypoglycaemia in the preceding 6 months; more frequently received aspirin, statins, ACE inhibitors, or angiotensin receptor blockers, and were more likely to achieve blood pressure and low-density lipoprotein-cholesterol targets. Only 15.4 and 12.0% of patients with and without CAD (P = 0.002), respectively, achieved all three guideline-recommended targets. Compared with patients with diabetes without CAD, those with CAD more frequently had a less stringent A1C target selected by their PCPs but achieved similar glycaemic control. Overall, risk factor management remained suboptimal in both groups. There remains an important opportunity to improve the care and outcome of patients with diabetes.
Huo, Zhimin; Summers, Ronald M.; Paquerault, Sophie; Lo, Joseph; Hoffmeister, Jeffrey; Armato, Samuel G.; Freedman, Matthew T.; Lin, Jesse; Ben Lo, Shih-Chung; Petrick, Nicholas; Sahiner, Berkman; Fryd, David; Yoshida, Hiroyuki; Chan, Heang-Ping
2013-01-01
Computer-aided detection/diagnosis (CAD) is increasingly used for decision support by clinicians for detection and interpretation of diseases. However, there are no quality assurance (QA) requirements for CAD in clinical use at present. QA of CAD is important so that end users can be made aware of changes in CAD performance both due to intentional or unintentional causes. In addition, end-user training is critical to prevent improper use of CAD, which could potentially result in lower overall clinical performance. Research on QA of CAD and user training are limited to date. The purpose of this paper is to bring attention to these issues, inform the readers of the opinions of the members of the American Association of Physicists in Medicine (AAPM) CAD subcommittee, and thus stimulate further discussion in the CAD community on these topics. The recommendations in this paper are intended to be work items for AAPM task groups that will be formed to address QA and user training issues on CAD in the future. The work items may serve as a framework for the discussion and eventual design of detailed QA and training procedures for physicists and users of CAD. Some of the recommendations are considered by the subcommittee to be reasonably easy and practical and can be implemented immediately by the end users; others are considered to be “best practice” approaches, which may require significant effort, additional tools, and proper training to implement. The eventual standardization of the requirements of QA procedures for CAD will have to be determined through consensus from members of the CAD community, and user training may require support of professional societies. It is expected that high-quality CAD and proper use of CAD could allow these systems to achieve their true potential, thus benefiting both the patients and the clinicians, and may bring about more widespread clinical use of CAD for many other diseases and applications. It is hoped that the awareness of the need for appropriate CAD QA and user training will stimulate new ideas and approaches for implementing such procedures efficiently and effectively as well as funding opportunities to fulfill such critical efforts. PMID:23822459
[Computed tomography with computer-assisted detection of pulmonary nodules in dogs and cats].
Niesterok, C; Piesnack, S; Köhler, C; Ludewig, E; Alef, M; Kiefer, I
2015-01-01
The aim of this study was to assess the potential benefit of computer-assisted detection (CAD) of pulmonary nodules in veterinary medicine. Therefore, the CAD rate was compared to the detection rates of two individual examiners in terms of its sensitivity and false-positive findings. We included 51 dogs and 16 cats with pulmonary nodules previously diagnosed by computed tomography. First, the number of nodules ≥ 3 mm was recorded for each patient by two independent examiners. Subsequently, each examiner used the CAD software for automated nodule detection. With the knowledge of the CAD results, a final consensus decision on the number of nodules was achieved. The software used was a commercially available CAD program. The sensitivity of examiner 1 was 89.2%, while that of examiner 2 reached 87.4%. CAD had a sensitivity of 69.4%. With CAD, the sensitivity of examiner 1 increased to 94.7% and that of examiner 2 to 90.8%. The CAD-system, which we used in our study, had a moderate sensitivity of 69.4%. Despite its severe limitations, with a high level of false-positive and false-negative results, CAD increased the examiners' sensitivity. Therefore, its supportive role in diagnostics appears to be evident.
The application of CAD / CAM technology in Dentistry
NASA Astrophysics Data System (ADS)
Susic, I.; Travar, M.; Susic, M.
2017-05-01
Information and communication technologies have found their application in the healthcare sector, including the frameworks of modern dentistry. CAD / CAM application in dentistry is the process by which is attained finished dental restoration through fine milling process of ready ceramic blocks. CAD / CAM is an acronym of english words Computer-Aided-Design (CAD) / Computer-Aided-Manufacture (CAM), respectively dental computer aided design and computer aided manufacture of inlays, onlays, crowns and bridges. CAD / CAM technology essentially allows you to create a two-dimensional and three-dimensional models and their materialization by numerical controlled machines. In order to operate more efficiently, reduce costs, increase user/patient satisfaction and ultimately achieve profits, many dental offices in the world have their attention focused on implementation of modern IT solutions in everyday practice. In addition to the specialized clinic management software, inventory control, etc., or hardware such as the use of lasers in cosmetic dentistry or intraoral scanning, recently the importance is given to the application of CAD / CAM technology in the field of prosthetic. After the removal of pathologically altered tooth structure, it is necessary to achieve restoration that will be most similar to the anatomy of a natural tooth. Applying CAD / CAM technology on applicable ceramic blocks it can be obtained very quick, but also very accurate restoration, in the forms of inlays, onlays, bridges and crowns. The paper presents the advantages of using this technology as well as satisfaction of the patients and dentists by using systems as: Cercon, Celay, Cerec, Lava, Everest, which represent imperative of modern dentistry in creating fixed dental restorations.
Tartar, A; Akan, A; Kilic, N
2014-01-01
Computer-aided detection systems can help radiologists to detect pulmonary nodules at an early stage. In this paper, a novel Computer-Aided Diagnosis system (CAD) is proposed for the classification of pulmonary nodules as malignant and benign. The proposed CAD system using ensemble learning classifiers, provides an important support to radiologists at the diagnosis process of the disease, achieves high classification performance. The proposed approach with bagging classifier results in 94.7 %, 90.0 % and 77.8 % classification sensitivities for benign, malignant and undetermined classes (89.5 % accuracy), respectively.
Prototypes for Content-Based Image Retrieval in Clinical Practice
Depeursinge, Adrien; Fischer, Benedikt; Müller, Henning; Deserno, Thomas M
2011-01-01
Content-based image retrieval (CBIR) has been proposed as key technology for computer-aided diagnostics (CAD). This paper reviews the state of the art and future challenges in CBIR for CAD applied to clinical practice. We define applicability to clinical practice by having recently demonstrated the CBIR system on one of the CAD demonstration workshops held at international conferences, such as SPIE Medical Imaging, CARS, SIIM, RSNA, and IEEE ISBI. From 2009 to 2011, the programs of CADdemo@CARS and the CAD Demonstration Workshop at SPIE Medical Imaging were sought for the key word “retrieval” in the title. The systems identified were analyzed and compared according to the hierarchy of gaps for CBIR systems. In total, 70 software demonstrations were analyzed. 5 systems were identified meeting the criterions. The fields of application are (i) bone age assessment, (ii) bone fractures, (iii) interstitial lung diseases, and (iv) mammography. Bridging the particular gaps of semantics, feature extraction, feature structure, and evaluation have been addressed most frequently. In specific application domains, CBIR technology is available for clinical practice. While system development has mainly focused on bridging content and feature gaps, performance and usability have become increasingly important. The evaluation must be based on a larger set of reference data, and workflow integration must be achieved before CBIR-CAD is really established in clinical practice. PMID:21892374
NASA Astrophysics Data System (ADS)
Liu, Jiamin; Wang, Shijun; Kabadi, Suraj; Summers, Ronald M.
2009-02-01
CT colonography (CTC) is a feasible and minimally invasive method for the detection of colorectal polyps and cancer screening. Computer-aided detection (CAD) of polyps has improved consistency and sensitivity of virtual colonoscopy interpretation and reduced interpretation burden. A CAD system typically consists of four stages: (1) image preprocessing including colon segmentation; (2) initial detection generation; (3) feature selection; and (4) detection classification. In our experience, three existing problems limit the performance of our current CAD system. First, highdensity orally administered contrast agents in fecal-tagging CTC have scatter effects on neighboring tissues. The scattering manifests itself as an artificial elevation in the observed CT attenuation values of the neighboring tissues. This pseudo-enhancement phenomenon presents a problem for the application of computer-aided polyp detection, especially when polyps are submerged in the contrast agents. Second, general kernel approach for surface curvature computation in the second stage of our CAD system could yield erroneous results for thin structures such as small (6-9 mm) polyps and for touching structures such as polyps that lie on haustral folds. Those erroneous curvatures will reduce the sensitivity of polyp detection. The third problem is that more than 150 features are selected from each polyp candidate in the third stage of our CAD system. These high dimensional features make it difficult to learn a good decision boundary for detection classification and reduce the accuracy of predictions. Therefore, an improved CAD system for polyp detection in CTC data is proposed by introducing three new techniques. First, a scale-based scatter correction algorithm is applied to reduce pseudo-enhancement effects in the image pre-processing stage. Second, a cubic spline interpolation method is utilized to accurately estimate curvatures for initial detection generation. Third, a new dimensionality reduction classifier, diffusion map and local linear embedding (DMLLE), is developed for classification and false positives (FP) reduction. Performance of the improved CAD system is evaluated and compared with our existing CAD system (without applying those techniques) using CT scans of 1186 patients. These scans are divided into a training set and a test set. The sensitivity of the improved CAD system increased 18% on training data at a rate of 5 FPs per patient and 15% on test data at a rate of 5 FPs per patient. Our results indicated that the improved CAD system achieved significantly better performance on medium-sized colonic adenomas with higher sensitivity and lower FP rate in CTC.
An interactive system for computer-aided diagnosis of breast masses.
Wang, Xingwei; Li, Lihua; Liu, Wei; Xu, Weidong; Lederman, Dror; Zheng, Bin
2012-10-01
Although mammography is the only clinically accepted imaging modality for screening the general population to detect breast cancer, interpreting mammograms is difficult with lower sensitivity and specificity. To provide radiologists "a visual aid" in interpreting mammograms, we developed and tested an interactive system for computer-aided detection and diagnosis (CAD) of mass-like cancers. Using this system, an observer can view CAD-cued mass regions depicted on one image and then query any suspicious regions (either cued or not cued by CAD). CAD scheme automatically segments the suspicious region or accepts manually defined region and computes a set of image features. Using content-based image retrieval (CBIR) algorithm, CAD searches for a set of reference images depicting "abnormalities" similar to the queried region. Based on image retrieval results and a decision algorithm, a classification score is assigned to the queried region. In this study, a reference database with 1,800 malignant mass regions and 1,800 benign and CAD-generated false-positive regions was used. A modified CBIR algorithm with a new function of stretching the attributes in the multi-dimensional space and decision scheme was optimized using a genetic algorithm. Using a leave-one-out testing method to classify suspicious mass regions, we compared the classification performance using two CBIR algorithms with either equally weighted or optimally stretched attributes. Using the modified CBIR algorithm, the area under receiver operating characteristic curve was significantly increased from 0.865 ± 0.006 to 0.897 ± 0.005 (p < 0.001). This study demonstrated the feasibility of developing an interactive CAD system with a large reference database and achieving improved performance.
Computer-aided detection of prostate cancer in T2-weighted MRI within the peripheral zone
NASA Astrophysics Data System (ADS)
Rampun, Andrik; Zheng, Ling; Malcolm, Paul; Tiddeman, Bernie; Zwiggelaar, Reyer
2016-07-01
In this paper we propose a prostate cancer computer-aided diagnosis (CAD) system and suggest a set of discriminant texture descriptors extracted from T2-weighted MRI data which can be used as a good basis for a multimodality system. For this purpose, 215 texture descriptors were extracted and eleven different classifiers were employed to achieve the best possible results. The proposed method was tested based on 418 T2-weighted MR images taken from 45 patients and evaluated using 9-fold cross validation with five patients in each fold. The results demonstrated comparable results to existing CAD systems using multimodality MRI. We achieved an area under the receiver operating curve (A z ) values equal to 90.0%+/- 7.6% , 89.5%+/- 8.9% , 87.9%+/- 9.3% and 87.4%+/- 9.2% for Bayesian networks, ADTree, random forest and multilayer perceptron classifiers, respectively, while a meta-voting classifier using average probability as a combination rule achieved 92.7%+/- 7.4% .
NASA Astrophysics Data System (ADS)
Wei, Jun; Sahiner, Berkman; Hadjiiski, Lubomir M.; Chan, Heang-Ping; Helvie, Mark A.; Roubidoux, Marilyn A.; Zhou, Chuan; Ge, Jun; Zhang, Yiheng
2006-03-01
We are developing a two-view information fusion method to improve the performance of our CAD system for mass detection. Mass candidates on each mammogram were first detected with our single-view CAD system. Potential object pairs on the two-view mammograms were then identified by using the distance between the object and the nipple. Morphological features, Hessian feature, correlation coefficients between the two paired objects and texture features were used as input to train a similarity classifier that estimated a similarity scores for each pair. Finally, a linear discriminant analysis (LDA) classifier was used to fuse the score from the single-view CAD system and the similarity score. A data set of 475 patients containing 972 mammograms with 475 biopsy-proven masses was used to train and test the CAD system. All cases contained the CC view and the MLO or LM view. We randomly divided the data set into two independent sets of 243 cases and 232 cases. The training and testing were performed using the 2-fold cross validation method. The detection performance of the CAD system was assessed by free response receiver operating characteristic (FROC) analysis. The average test FROC curve was obtained from averaging the FP rates at the same sensitivity along the two corresponding test FROC curves from the 2-fold cross validation. At the case-based sensitivities of 90%, 85% and 80% on the test set, the single-view CAD system achieved an FP rate of 2.0, 1.5, and 1.2 FPs/image, respectively. With the two-view fusion system, the FP rates were reduced to 1.7, 1.3, and 1.0 FPs/image, respectively, at the corresponding sensitivities. The improvement was found to be statistically significant (p<0.05) by the AFROC method. Our results indicate that the two-view fusion scheme can improve the performance of mass detection on mammograms.
Quality of medical management in coronary artery disease.
Al Shammeri, Owayed; Stafford, Randall S; Alzenaidi, Ahlam; Al-Hutaly, Bushra; Abdulmonem, Alaa
2014-01-01
Patients with coronary artery disease (CAD) are at high risk of recurrent adverse cardiac events. Such risk can be diminished through a guideline-recommend optimal medical therapy (OMT), defined as adherence to appropriate antiplatelet therapy, lipid-lowering agents, beta-blockers and angio.tensin-converting enzyme inhibitors, blood pressure < 140/90 mm Hg ( < 130/80 mm Hg in diabetics and renal disease patients), low-density lipoprotein (LDL) < 2 mmol/L, smoking cessation and aerobic physical activity, and hemoglobin (Hb) A1c < 7%. Unfortunately, preliminary data suggest a wide gap between recommended and actual practices. The study aims to estimate the rate of achieving of OMT in CAD patients in Qassim Province. This observational study enrolled 207 consecutive CAD patients seen in cardiology clinic in Prince Sultan Cardiac Center in Qassim between January 2012 and May 2012. Eligible participants were over the age of 18, with CAD documented by either noninvasive testing or by coronary angiogram. We collected the demographic, medications, laboratory, and clinical data through in-person interviews, medical records, and an electronic patient database. OMT was achieved in only 10.4% of CAD patients. The rate of achievement of target systolic blood pressure was 76.5%, target diastolic blood pressure 88%, target LDL 68%, adherence to medications 91%. Diabetes was common (64% of all patients), and only 24% of these patients achieved the target HbA1c. The poor achievement of optimal medical therapy in CAD patients contributes to prevent.able mortality, morbidity, and health care costs. The observed shortcomings warrant investment in strategies to achieve OMT in these high-risk patients.
An integrated CAD/CAM/robotic milling method for custom cementless femoral prostheses.
Wen-ming, Xi; Ai-min, Wang; Qi, Wu; Chang-hua, Liu; Jian-fei, Zhu; Fang-fang, Xia
2015-09-01
Aseptic loosening is the primary cause of cementless femoral prosthesis failure and is related to the primary stability of the cementless femoral prosthesis in the femoral cavity. The primary stability affects both the osseointegration and the long-term stability of cementless femoral prostheses. A custom cementless femoral prosthesis can improve the fit and fill of the prosthesis in the femoral cavity and decrease the micromotion of the proximal prosthesis such that the primary stability of the custom prosthesis can be improved, and osseointegration of the proximal prosthesis is achieved. These results will help to achieve long-term stability in total hip arthroplasty (THA). In this paper, we introduce an integrated CAD/CAM/robotic method of milling custom cementless femoral prostheses. The 3D reconstruction model uses femoral CT images and 3D design software to design a CAD model of the custom prosthesis. After the transformation matrices between two units of the robotic system are calibrated, consistency between the CAM software and the robotic system can be achieved, and errors in the robotic milling can be limited. According to the CAD model of the custom prosthesis, the positions of the robotic tool points are produced by the CAM software of the CNC machine. The normal vector of the three adjacent robotic tool point positions determines the pose of the robotic tool point. In conclusion, the fit rate of custom pig femur stems in the femoral cavities was 90.84%. After custom femoral prostheses were inserted into the femoral cavities, the maximum gaps between the prostheses and the cavities measured less than 1 mm at the diaphysis and 1.3 mm at the metaphysis. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
Wong, M S; Cheng, C Y; Ng, B K W; Lam, T P; Chiu, S W
2006-01-01
Spinal orthoses are commonly prescribed to patients with moderate AIS for prevention of further deterioration. In a conventional manufacturing method, plaster bandages are used to get patient's body contour and plaster cast is rectified manually. With the introduction of CAD/CAM system, a series of automated processes from body scanning to digital rectification and milling of positive model can be performed in a fast and accurate fashion. This project is to study the impact of CAD/CAM method as compared with the conventional method. In assessing the 147 recruited subjects fitted with spinal orthoses (43 subjects using conventional method and 104 subjects using CAD/CAM method), significant decreases (p<0.05) were found in the Cobb angles when comparing the pre-intervention data with that of the first year of intervention. Regarding the learning curve, Orthotists are getting more competent with the CAD/CAM technique in four years time. The mean productivity of the CAD/CAM method is 2.75 times higher than that of the conventional method. The CAD/CAM method could achieve similar clinical outcomes and with its high efficiency, could be considered as substitute for conventional methods in fabricating spinal orthoses for patients with AIS.
Therapeutic interventions and success in risk factor control for secondary prevention of stroke.
Alvarez-Sabin, Jose; Quintana, Manuel; Hernandez-Presa, Miguel Angel; Alvarez, Carlos; Chaves, Jose; Ribo, Marc
2009-01-01
We sought to evaluate the success rates in achieving preventive therapeutic goals in patients who experienced an ischemic stroke (IS) and compare them with those achieved in patients with coronary artery disease (CAD). This was an observational multicenter case-control study (3 patients with IS and one control subject with CAD) performed in 1444 primary health centers in Spain. Preventive therapeutic objectives according to American Heart Association guidelines were predefined. Demographic data, vascular risk factors, and success/failure in achievement of objectives were recorded and compared between patients with IS and CAD. A total of 5458 patients were included, 4098 (75.1%) had IS and 1360 (24.9%) had CAD. Although more than 90% of patients with hypertension, diabetes, or dyslipidemia were under specific drug regimens, only about 25% achieved the recommended therapeutic objective for each risk factor. Success rate was especially low among patients with IS compared with CAD: hypertension (23.8% v 27.2%; P = .028); dyslipidemia (13.6% v 20.3%; P < .001); and abdominal obesity (49.1% v 54.6%; P = .002). The only objective widely achieved in both groups was the use of antithrombotic drugs in atrial fibrillation (97.2% v 94.7%; P = .125). Only 3.3% of patients with IS had all risk factors under control, compared with 5.6% of those with CAD (P = .006). For all patients, multivariate logistic regression model showed that independent predictors of full risk factor control were: presence of CAD as compared with IS (odds ratio [OR] 2.11; 95% confidence interval [CI] 1.35-3.29; P = .001), older age (OR 1.02; 95% CI 1.00-1.04; P = .028), and having less than 3 risk factors (OR 16.98; 95% CI 9.02-31.97; P < .001). Success in achieving preventive therapeutic objectives for secondary prevention of vascular events is low, especially among patients with IS. There is an urgent need to devise strategies to improve risk factor control.
Computer-aided diagnosis of breast microcalcifications based on dual-tree complex wavelet transform.
Jian, Wushuai; Sun, Xueyan; Luo, Shuqian
2012-12-19
Digital mammography is the most reliable imaging modality for breast carcinoma diagnosis and breast micro-calcifications is regarded as one of the most important signs on imaging diagnosis. In this paper, a computer-aided diagnosis (CAD) system is presented for breast micro-calcifications based on dual-tree complex wavelet transform (DT-CWT) to facilitate radiologists like double reading. Firstly, 25 abnormal ROIs were extracted according to the center and diameter of the lesions manually and 25 normal ROIs were selected randomly. Then micro-calcifications were segmented by combining space and frequency domain techniques. We extracted three texture features based on wavelet (Haar, DB4, DT-CWT) transform. Totally 14 descriptors were introduced to define the characteristics of the suspicious micro-calcifications. Principal Component Analysis (PCA) was used to transform these descriptors to a compact and efficient vector expression. Support Vector Machine (SVM) classifier was used to classify potential micro-calcifications. Finally, we used the receiver operating characteristic (ROC) curve and free-response operating characteristic (FROC) curve to evaluate the performance of the CAD system. The results of SVM classifications based on different wavelets shows DT-CWT has a better performance. Compared with other results, DT-CWT method achieved an accuracy of 96% and 100% for the classification of normal and abnormal ROIs, and the classification of benign and malignant micro-calcifications respectively. In FROC analysis, our CAD system for clinical dataset detection achieved a sensitivity of 83.5% at a false positive per image of 1.85. Compared with general wavelets, DT-CWT could describe the features more effectively, and our CAD system had a competitive performance.
Computer-aided diagnosis of breast microcalcifications based on dual-tree complex wavelet transform
2012-01-01
Background Digital mammography is the most reliable imaging modality for breast carcinoma diagnosis and breast micro-calcifications is regarded as one of the most important signs on imaging diagnosis. In this paper, a computer-aided diagnosis (CAD) system is presented for breast micro-calcifications based on dual-tree complex wavelet transform (DT-CWT) to facilitate radiologists like double reading. Methods Firstly, 25 abnormal ROIs were extracted according to the center and diameter of the lesions manually and 25 normal ROIs were selected randomly. Then micro-calcifications were segmented by combining space and frequency domain techniques. We extracted three texture features based on wavelet (Haar, DB4, DT-CWT) transform. Totally 14 descriptors were introduced to define the characteristics of the suspicious micro-calcifications. Principal Component Analysis (PCA) was used to transform these descriptors to a compact and efficient vector expression. Support Vector Machine (SVM) classifier was used to classify potential micro-calcifications. Finally, we used the receiver operating characteristic (ROC) curve and free-response operating characteristic (FROC) curve to evaluate the performance of the CAD system. Results The results of SVM classifications based on different wavelets shows DT-CWT has a better performance. Compared with other results, DT-CWT method achieved an accuracy of 96% and 100% for the classification of normal and abnormal ROIs, and the classification of benign and malignant micro-calcifications respectively. In FROC analysis, our CAD system for clinical dataset detection achieved a sensitivity of 83.5% at a false positive per image of 1.85. Conclusions Compared with general wavelets, DT-CWT could describe the features more effectively, and our CAD system had a competitive performance. PMID:23253202
ERIC Educational Resources Information Center
Resetarits, Paul J.
1989-01-01
Studies whether traditional drafting equipment (TRAD) or computer aided drafting equipment (CAD) is more effective. Proposes that students using only CAD can learn principles of drafting as well as students using only TRAD. Reports no significant difference either on achievement or attitude. (MVL)
A new data integration approach for AutoCAD and GIS
NASA Astrophysics Data System (ADS)
Ye, Hongmei; Li, Yuhong; Wang, Cheng; Li, Lijun
2006-10-01
GIS has its advantages both on spatial data analysis and management, particularly on the geometric and attributive information management, which has also attracted lots attentions among researchers around world. AutoCAD plays more and more important roles as one of the main data sources of GIS. Various work and achievements can be found in the related literature. However, the conventional data integration from AutoCAD to GIS is time-consuming, which also can cause the information loss both in the geometric aspects and the attributive aspects for a large system. It is necessary and urgent to sort out new approach and algorithm for the efficient high-quality data integration. In this paper, a novel data integration approach from AutoCAD to GIS will be introduced based on the spatial data mining technique through the data structure analysis both in the AutoCAD and GIS. A practicable algorithm for the data conversion from CAD to GIS will be given as well. By a designed evaluation scheme, the accuracy of the conversion both in the geometric and the attributive information will be demonstrated. Finally, the validity and feasibility of the new approach will be shown by an experimental analysis.
Lutfi, Mohamed Faisal
2017-01-01
Anxiety and cardiac autonomic modulations (CAM) were thoroughly investigated in coronary artery disease (CAD) and cardiac syndrome X (CSX) patients worldwide, but not among Sudanese with similar pathology. To compare levels of anxiety and CAM between Sudanese patients with CSX and CAD. Anxiety was evaluated in 51 CAD and 26 CSX patients using Taylor Manifest anxiety score (TMAS) questionnaire while heart rate variability derived indices were used to assess CAM, namely natural logarithm of low frequency (LnLF), high frequency (LnHF) and LF/HF ratio (LnLF/HF). Low anxiety levels were achieved by 6 (23.1%) and 9 (17.6%) patients with CSX and CAD respectively. High anxiety level was achieved by only one (3.8%) patient, who was suffering from CSX. TMAS was significantly higher in CSX (31.27 (21.97)) compared to CAD (21.86 (12.97), P = 0.021). However, abnormally increased anxiety was not associated with higher risk of CSX. LnLF, LnHF and LnLF/HF were comparable in CAD and CSX patients. CSX and CAD patients showed comparable CAM. Although anxiety levels were higher in CSX compared to CAD, TMAS ≥ 35 failed to show significant association with CSX.
Targeted Assessment for Prevention of Healthcare-Associated Infections: A New Prioritization Metric.
Soe, Minn M; Gould, Carolyn V; Pollock, Daniel; Edwards, Jonathan
2015-12-01
To develop a method for calculating the number of healthcare-associated infections (HAIs) that must be prevented to reach a HAI reduction goal and identifying and prioritizing healthcare facilities where the largest reductions can be achieved. Acute care hospitals that report HAI data to the Centers for Disease Control and Prevention's National Healthcare Safety Network. METHODS :The cumulative attributable difference (CAD) is calculated by subtracting a numerical prevention target from an observed number of HAIs. The prevention target is the product of the predicted number of HAIs and a standardized infection ratio goal, which represents a HAI reduction goal. The CAD is a numeric value that if positive is the number of infections to prevent to reach the HAI reduction goal. We calculated the CAD for catheter-associated urinary tract infections for each of the 3,639 hospitals that reported such data to National Healthcare Safety Network in 2013 and ranked the hospitals by their CAD values in descending order. Of 1,578 hospitals with positive CAD values, preventing 10,040 catheter-associated urinary tract infections at 293 hospitals (19%) with the highest CAD would enable achievement of the national 25% catheter-associated urinary tract infection reduction goal. The CAD is a new metric that facilitates ranking of facilities, and locations within facilities, to prioritize HAI prevention efforts where the greatest impact can be achieved toward a HAI reduction goal.
Use of CAD systems in design of Space Station and space robots
NASA Technical Reports Server (NTRS)
Dwivedi, Suren N.; Yadav, P.; Jones, Gary; Travis, Elmer W.
1988-01-01
The evolution of CAD systems is traced. State-of-the-art CAD systems are reviewed and various advanced CAD facilities and supplementing systems being used at NASA-Goddard are described. CAD hardware, computer software, and protocols are detailed.
Targeted Assessment for Prevention of Healthcare-Associated Infections: A New Prioritization Metric
Soe, Minn M.; Gould, Carolyn V.; Pollock, Daniel; Edwards, Jonathan
2015-01-01
OBJECTIVE To develop a method for calculating the number of healthcare-associated infections (HAIs) that must be prevented to reach a HAI reduction goal and identifying and prioritizing healthcare facilities where the largest reductions can be achieved. SETTING Acute care hospitals that report HAI data to the Centers for Disease Control and Prevention’s National Healthcare Safety Network. METHODS The cumulative attributable difference (CAD) is calculated by subtracting a numerical prevention target from an observed number of HAIs. The prevention target is the product of the predicted number of HAIs and a standardized infection ratio goal, which represents a HAI reduction goal. The CAD is a numeric value that if positive is the number of infections to prevent to reach the HAI reduction goal. We calculated the CAD for catheter-associated urinary tract infections for each of the 3,639 hospitals that reported such data to National Healthcare Safety Network in 2013 and ranked the hospitals by their CAD values in descending order. RESULTS Of 1,578 hospitals with positive CAD values, preventing 10,040 catheter-associated urinary tract infections at 293 hospitals (19%) with the highest CAD would enable achievement of the national 25% catheter-associated urinary tract infection reduction goal. CONCLUSION The CAD is a new metric that facilitates ranking of facilities, and locations within facilities, to prioritize HAI prevention efforts where the greatest impact can be achieved toward a HAI reduction goal. PMID:26310913
Tuner control system of Spoke012 SRF cavity for C-ADS injector I
NASA Astrophysics Data System (ADS)
Liu, Na; Sun, Yi; Wang, Guang-Wei; Mi, Zheng-Hui; Lin, Hai-Ying; Wang, Qun-Yao; Liu, Rong; Ma, Xin-Peng
2016-09-01
A new tuner control system for spoke superconducting radio frequency (SRF) cavities has been developed and applied to cryomodule I of the C-ADS injector I at the Institute of High Energy Physics, Chinese Academy of Sciences. We have successfully implemented the tuner controller based on Programmable Logic Controller (PLC) for the first time and achieved a cavity tuning phase error of ±0.7° (about ±4 Hz peak to peak) in the presence of electromechanical coupled resonance. This paper presents preliminary experimental results based on the PLC tuner controller under proton beam commissioning. Supported by Proton linac accelerator I of China Accelerator Driven sub-critical System (Y12C32W129)
Park, Sang Cheol; Chapman, Brian E; Zheng, Bin
2011-06-01
This study developed a computer-aided detection (CAD) scheme for pulmonary embolism (PE) detection and investigated several approaches to improve CAD performance. In the study, 20 computed tomography examinations with various lung diseases were selected, which include 44 verified PE lesions. The proposed CAD scheme consists of five basic steps: 1) lung segmentation; 2) PE candidate extraction using an intensity mask and tobogganing region growing; 3) PE candidate feature extraction; 4) false-positive (FP) reduction using an artificial neural network (ANN); and 5) a multifeature-based k-nearest neighbor for positive/negative classification. In this study, we also investigated the following additional methods to improve CAD performance: 1) grouping 2-D detected features into a single 3-D object; 2) selecting features with a genetic algorithm (GA); and 3) limiting the number of allowed suspicious lesions to be cued in one examination. The results showed that 1) CAD scheme using tobogganing, an ANN, and grouping method achieved the maximum detection sensitivity of 79.2%; 2) the maximum scoring method achieved the superior performance over other scoring fusion methods; 3) GA was able to delete "redundant" features and further improve CAD performance; and 4) limiting the maximum number of cued lesions in an examination reduced FP rate by 5.3 times. Combining these approaches, CAD scheme achieved 63.2% detection sensitivity with 18.4 FP lesions per examination. The study suggested that performance of CAD schemes for PE detection depends on many factors that include 1) optimizing the 2-D region grouping and scoring methods; 2) selecting the optimal feature set; and 3) limiting the number of allowed cueing lesions per examination.
Chang, Ruey-Feng; Lee, Chung-Chien; Lo, Chung-Ming
2016-09-01
The lifetime prevalence of shoulder pain approaches 70%, which is mostly attributable to rotator cuff lesions such as inflammation, calcific tendinitis and tears. On clinical examination, shoulder ultrasound is recommended for the detection of lesions. However, there exists inter-operator variability in diagnostic accuracy because of differences in the experience and expertise of operators. In this study, a computer-aided diagnosis (CAD) system was developed to assist ultrasound operators in diagnosing rotator cuff lesions and to improve the practicality of ultrasound examination. The collected cases included 43 cases of inflammation, 30 cases of calcific tendinitis and 26 tears. For each case, the lesion area and texture features were extracted from the entire lesions and combined in a multinomial logistic regression classifier for lesion classification. The proposed CAD achieved an accuracy of 87.9%. The individual accuracy of this CAD system was 88.4% for inflammation, 83.3% for calcific tendinitis and 92.3% for tears. Cohen's k was 0.798. On the basis of its diagnostic performance, clinical use of this CAD technique has promise. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Lee, Donghoon; Kim, Ye-seul; Choi, Sunghoon; Lee, Haenghwa; Jo, Byungdu; Choi, Seungyeon; Shin, Jungwook; Kim, Hee-Joung
2017-03-01
The chest digital tomosynthesis(CDT) is recently developed medical device that has several advantage for diagnosing lung disease. For example, CDT provides depth information with relatively low radiation dose compared to computed tomography (CT). However, a major problem with CDT is the image artifacts associated with data incompleteness resulting from limited angle data acquisition in CDT geometry. For this reason, the sensitivity of lung disease was not clear compared to CT. In this study, to improve sensitivity of lung disease detection in CDT, we developed computer aided diagnosis (CAD) systems based on machine learning. For design CAD systems, we used 100 cases of lung nodules cropped images and 100 cases of normal lesion cropped images acquired by lung man phantoms and proto type CDT. We used machine learning techniques based on support vector machine and Gabor filter. The Gabor filter was used for extracting characteristics of lung nodules and we compared performance of feature extraction of Gabor filter with various scale and orientation parameters. We used 3, 4, 5 scales and 4, 6, 8 orientations. After extracting features, support vector machine (SVM) was used for classifying feature of lesions. The linear, polynomial and Gaussian kernels of SVM were compared to decide the best SVM conditions for CDT reconstruction images. The results of CAD system with machine learning showed the capability of automatically lung lesion detection. Furthermore detection performance was the best when Gabor filter with 5 scale and 8 orientation and SVM with Gaussian kernel were used. In conclusion, our suggested CAD system showed improving sensitivity of lung lesion detection in CDT and decide Gabor filter and SVM conditions to achieve higher detection performance of our developed CAD system for CDT.
A citizen science approach to optimising computer aided detection (CAD) in mammography
NASA Astrophysics Data System (ADS)
Ionescu, Georgia V.; Harkness, Elaine F.; Hulleman, Johan; Astley, Susan M.
2018-03-01
Computer aided detection (CAD) systems assist medical experts during image interpretation. In mammography, CAD systems prompt suspicious regions which help medical experts to detect early signs of cancer. This is a challenging task and prompts may appear in regions that are actually normal, whilst genuine cancers may be missed. The effect prompting has on readers performance is not fully known. In order to explore the effects of prompting errors, we have created an online game (Bat Hunt), designed for non-experts, that mirrors mammographic CAD. This allows us to explore a wider parameter space. Users are required to detect bats in images of flocks of birds, with image difficulty matched to the proportions of screening mammograms in different BI-RADS density categories. Twelve prompted conditions were investigated, along with unprompted detection. On average, players achieved a sensitivity of 0.33 for unprompted detection, and sensitivities of 0.75, 0.83, and 0.92 respectively for 70%, 80%, and 90% of targets prompted, regardless of CAD specificity. False prompts distract players from finding unprompted targets if they appear in the same image. Player performance decreases when the number of false prompts increases, and increases proportionally with prompting sensitivity. Median lowest d' was for unprompted condition (1.08) and the highest for sensitivity 90% and 0.5 false prompts per image (d'=4.48).
Chang, Yongjun; Paul, Anjan Kumar; Kim, Namkug; Baek, Jung Hwan; Choi, Young Jun; Ha, Eun Ju; Lee, Kang Dae; Lee, Hyoung Shin; Shin, DaeSeock; Kim, Nakyoung
2016-01-01
To develop a semiautomated computer-aided diagnosis (cad) system for thyroid cancer using two-dimensional ultrasound images that can be used to yield a second opinion in the clinic to differentiate malignant and benign lesions. A total of 118 ultrasound images that included axial and longitudinal images from patients with biopsy-confirmed malignant (n = 30) and benign (n = 29) nodules were collected. Thyroid cad software was developed to extract quantitative features from these images based on thyroid nodule segmentation in which adaptive diffusion flow for active contours was used. Various features, including histogram, intensity differences, elliptical fit, gray-level co-occurrence matrixes, and gray-level run-length matrixes, were evaluated for each region imaged. Based on these imaging features, a support vector machine (SVM) classifier was used to differentiate benign and malignant nodules. Leave-one-out cross-validation with sequential forward feature selection was performed to evaluate the overall accuracy of this method. Additionally, analyses with contingency tables and receiver operating characteristic (ROC) curves were performed to compare the performance of cad with visual inspection by expert radiologists based on established gold standards. Most univariate features for this proposed cad system attained accuracies that ranged from 78.0% to 83.1%. When optimal SVM parameters that were established using a grid search method with features that radiologists use for visual inspection were employed, the authors could attain rates of accuracy that ranged from 72.9% to 84.7%. Using leave-one-out cross-validation results in a multivariate analysis of various features, the highest accuracy achieved using the proposed cad system was 98.3%, whereas visual inspection by radiologists reached 94.9% accuracy. To obtain the highest accuracies, "axial ratio" and "max probability" in axial images were most frequently included in the optimal feature sets for the authors' proposed cad system, while "shape" and "calcification" in longitudinal images were most frequently included in the optimal feature sets for visual inspection by radiologists. The computed areas under curves in the ROC analysis were 0.986 and 0.979 for the proposed cad system and visual inspection by radiologists, respectively; no significant difference was detected between these groups. The use of thyroid cad to differentiate malignant from benign lesions shows accuracy similar to that obtained via visual inspection by radiologists. Thyroid cad might be considered a viable way to generate a second opinion for radiologists in clinical practice.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang, Yongjun; Paul, Anjan Kumar; Kim, Namkug, E-mail: namkugkim@gmail.com
Purpose: To develop a semiautomated computer-aided diagnosis (CAD) system for thyroid cancer using two-dimensional ultrasound images that can be used to yield a second opinion in the clinic to differentiate malignant and benign lesions. Methods: A total of 118 ultrasound images that included axial and longitudinal images from patients with biopsy-confirmed malignant (n = 30) and benign (n = 29) nodules were collected. Thyroid CAD software was developed to extract quantitative features from these images based on thyroid nodule segmentation in which adaptive diffusion flow for active contours was used. Various features, including histogram, intensity differences, elliptical fit, gray-level co-occurrencemore » matrixes, and gray-level run-length matrixes, were evaluated for each region imaged. Based on these imaging features, a support vector machine (SVM) classifier was used to differentiate benign and malignant nodules. Leave-one-out cross-validation with sequential forward feature selection was performed to evaluate the overall accuracy of this method. Additionally, analyses with contingency tables and receiver operating characteristic (ROC) curves were performed to compare the performance of CAD with visual inspection by expert radiologists based on established gold standards. Results: Most univariate features for this proposed CAD system attained accuracies that ranged from 78.0% to 83.1%. When optimal SVM parameters that were established using a grid search method with features that radiologists use for visual inspection were employed, the authors could attain rates of accuracy that ranged from 72.9% to 84.7%. Using leave-one-out cross-validation results in a multivariate analysis of various features, the highest accuracy achieved using the proposed CAD system was 98.3%, whereas visual inspection by radiologists reached 94.9% accuracy. To obtain the highest accuracies, “axial ratio” and “max probability” in axial images were most frequently included in the optimal feature sets for the authors’ proposed CAD system, while “shape” and “calcification” in longitudinal images were most frequently included in the optimal feature sets for visual inspection by radiologists. The computed areas under curves in the ROC analysis were 0.986 and 0.979 for the proposed CAD system and visual inspection by radiologists, respectively; no significant difference was detected between these groups. Conclusions: The use of thyroid CAD to differentiate malignant from benign lesions shows accuracy similar to that obtained via visual inspection by radiologists. Thyroid CAD might be considered a viable way to generate a second opinion for radiologists in clinical practice.« less
Okamoto, Takumi; Koide, Tetsushi; Sugi, Koki; Shimizu, Tatsuya; Anh-Tuan Hoang; Tamaki, Toru; Raytchev, Bisser; Kaneda, Kazufumi; Kominami, Yoko; Yoshida, Shigeto; Mieno, Hiroshi; Tanaka, Shinji
2015-08-01
With the increase of colorectal cancer patients in recent years, the needs of quantitative evaluation of colorectal cancer are increased, and the computer-aided diagnosis (CAD) system which supports doctor's diagnosis is essential. In this paper, a hardware design of type identification module in CAD system for colorectal endoscopic images with narrow band imaging (NBI) magnification is proposed for real-time processing of full high definition image (1920 × 1080 pixel). A pyramid style image segmentation with SVMs for multi-size scan windows, which can be implemented on an FPGA with small circuit area and achieve high accuracy, is proposed for actual complex colorectal endoscopic images.
Machine Learning in Ultrasound Computer-Aided Diagnostic Systems: A Survey
Zhang, Fan; Li, Xuelong
2018-01-01
The ultrasound imaging is one of the most common schemes to detect diseases in the clinical practice. There are many advantages of ultrasound imaging such as safety, convenience, and low cost. However, reading ultrasound imaging is not easy. To support the diagnosis of clinicians and reduce the load of doctors, many ultrasound computer-aided diagnosis (CAD) systems are proposed. In recent years, the success of deep learning in the image classification and segmentation led to more and more scholars realizing the potential of performance improvement brought by utilizing the deep learning in the ultrasound CAD system. This paper summarized the research which focuses on the ultrasound CAD system utilizing machine learning technology in recent years. This study divided the ultrasound CAD system into two categories. One is the traditional ultrasound CAD system which employed the manmade feature and the other is the deep learning ultrasound CAD system. The major feature and the classifier employed by the traditional ultrasound CAD system are introduced. As for the deep learning ultrasound CAD, newest applications are summarized. This paper will be useful for researchers who focus on the ultrasound CAD system. PMID:29687000
Machine Learning in Ultrasound Computer-Aided Diagnostic Systems: A Survey.
Huang, Qinghua; Zhang, Fan; Li, Xuelong
2018-01-01
The ultrasound imaging is one of the most common schemes to detect diseases in the clinical practice. There are many advantages of ultrasound imaging such as safety, convenience, and low cost. However, reading ultrasound imaging is not easy. To support the diagnosis of clinicians and reduce the load of doctors, many ultrasound computer-aided diagnosis (CAD) systems are proposed. In recent years, the success of deep learning in the image classification and segmentation led to more and more scholars realizing the potential of performance improvement brought by utilizing the deep learning in the ultrasound CAD system. This paper summarized the research which focuses on the ultrasound CAD system utilizing machine learning technology in recent years. This study divided the ultrasound CAD system into two categories. One is the traditional ultrasound CAD system which employed the manmade feature and the other is the deep learning ultrasound CAD system. The major feature and the classifier employed by the traditional ultrasound CAD system are introduced. As for the deep learning ultrasound CAD, newest applications are summarized. This paper will be useful for researchers who focus on the ultrasound CAD system.
Shibata, Shizuma; Vieira, Luiz Clovis Cardoso; Baratieri, Luiz Narciso; Fu, Jiale; Hoshika, Shuhei; Matsuda, Yasuhiro; Sano, Hidehiko
2016-01-01
The purpose of this study was to evaluate the µTBS (microtensile bond strength) of currently available self-etching adhesives with an experimental self-etch adhesive in normal and caries-affected dentin, using a portable hardness measuring device, in order to standardize dentin Knoop hardness. Normal (ND) and caries-affected dentin (CAD) were obtained from twenty human molars with class II natural caries. The following adhesive systems were tested: Mega Bond (MB), a 2-step self-etching adhesive; MTB-200 (MTB), an experimental 1-step self-etching adhesive (1-SEA), and two commercially available one-step self-etching systems, G-Bond Plus (GB) and Adper Easy Bond (EB). MB-ND achieved the highest µTBS (p<0.05). The mean µTBS was statistically lower in CAD than in ND for all adhesives tested (p<0.05), and the 2-step self-etch adhesive achieved better overall performance than the 1-step self-etch adhesives.
Paquerault, Sophie; Hardy, Paul T; Wersto, Nancy; Chen, John; Smith, Robert C
2010-09-01
The aim of this study was to explore different computerized models (the "machine") as a means to achieve optimal use of computer-aided detection (CAD) systems and to investigate whether these models can play a primary role in clinical decision making and possibly replace a clinician's subjective decision for combining his or her own assessment with that provided by a CAD system. Data previously collected from a fully crossed, multiple-reader, multiple-case observer study with and without CAD by seven observers asked to identify simulated small masses on two separate sets of 100 mammographic images (low-contrast and high-contrast sets; ie, low-contrast and high-contrast simulated masses added to random locations on normal mammograms) were used. This allowed testing two relative sensitivities between the observers and CAD. Seven models that combined detection assessments from CAD standalone, unaided read, and CAD-aided read (second read and concurrent read) were developed using the leave-one-out technique for training and testing. These models were personalized for each observer. Detection performance accuracies were analyzed using the area under a portion of the free-response receiver-operating characteristic curve (AUFC), sensitivity, and number of false-positives per image. For the low-contrast set, the use of computerized models resulted in significantly higher AUFCs compared to the unaided read mode for all readers, whereas the increased AUFCs between CAD-aided (second and concurrent reads; ie, decisions made by the readers) and unaided read modes were statistically significant for a majority, but not all, of the readers (four and five of the seven readers, respectively). For the high-contrast set, there were no significant trends in the AUFCs whether or not a model was used to combine the original reading modes. Similar results were observed when using sensitivity as the figure of merit. However, the average number of false-positives per image resulting from the computerized models remained the same as that obtained from the unaided read modes. Individual computerized models (the machine) that combine image assessments from CAD standalone, unaided read, and CAD-aided read can increase detection performance compared to the reading done by the observer. However, relative sensitivity (ie, the difference in sensitivity between CAD standalone and unaided read) was a critical factor that determined incremental improvement in decision making, whether made by the observer or using computerized models. Published by Elsevier Inc.
Evaluation of computer-aided detection and diagnosis systems.
Petrick, Nicholas; Sahiner, Berkman; Armato, Samuel G; Bert, Alberto; Correale, Loredana; Delsanto, Silvia; Freedman, Matthew T; Fryd, David; Gur, David; Hadjiiski, Lubomir; Huo, Zhimin; Jiang, Yulei; Morra, Lia; Paquerault, Sophie; Raykar, Vikas; Samuelson, Frank; Summers, Ronald M; Tourassi, Georgia; Yoshida, Hiroyuki; Zheng, Bin; Zhou, Chuan; Chan, Heang-Ping
2013-08-01
Computer-aided detection and diagnosis (CAD) systems are increasingly being used as an aid by clinicians for detection and interpretation of diseases. Computer-aided detection systems mark regions of an image that may reveal specific abnormalities and are used to alert clinicians to these regions during image interpretation. Computer-aided diagnosis systems provide an assessment of a disease using image-based information alone or in combination with other relevant diagnostic data and are used by clinicians as a decision support in developing their diagnoses. While CAD systems are commercially available, standardized approaches for evaluating and reporting their performance have not yet been fully formalized in the literature or in a standardization effort. This deficiency has led to difficulty in the comparison of CAD devices and in understanding how the reported performance might translate into clinical practice. To address these important issues, the American Association of Physicists in Medicine (AAPM) formed the Computer Aided Detection in Diagnostic Imaging Subcommittee (CADSC), in part, to develop recommendations on approaches for assessing CAD system performance. The purpose of this paper is to convey the opinions of the AAPM CADSC members and to stimulate the development of consensus approaches and "best practices" for evaluating CAD systems. Both the assessment of a standalone CAD system and the evaluation of the impact of CAD on end-users are discussed. It is hoped that awareness of these important evaluation elements and the CADSC recommendations will lead to further development of structured guidelines for CAD performance assessment. Proper assessment of CAD system performance is expected to increase the understanding of a CAD system's effectiveness and limitations, which is expected to stimulate further research and development efforts on CAD technologies, reduce problems due to improper use, and eventually improve the utility and efficacy of CAD in clinical practice.
WE-E-217A-02: Methodologies for Evaluation of Standalone CAD System Performance.
Sahiner, B
2012-06-01
Standalone performance evaluation of a CAD system provides information about the abnormality detection or classification performance of the computerized system alone. Although the performance of the reader with CAD is the final step in CAD system assessment, standalone performance evaluation is an important component for several reasons: First, standalone evaluation informs the reader about the performance level of the CAD system and may have an impact on how the reader uses the system. Second, it provides essential information to the system designer for algorithm optimization during system development. Third, standalone evaluation can provide a detailed description of algorithm performance (e.g., on subgroups of the population) because a larger data set with more samples from different subgroups can be included in standalone studies compared to reader studies. Proper standalone evaluation of a CAD system involves a number of key components, some of which are shared with the assessment of reader performance with CAD. These include (1) selection of a test data set that allows performance assessment with little or no bias and acceptable uncertainty; (2) a reference standard that indicates disease status as well as the location and extent of disease; (3) a clearly defined method for labeling each CAD mark as a true-positive or false-positive; and (4) a properly selected set of metrics to summarize the accuracy of the computer marks and their corresponding scores. In this lecture, we will discuss various approaches for the key components of standalone CAD performance evaluation listed above, and present some of the recommendations and opinions from the AAPM CAD subcommittee on these issues. Learning Objectives 1. Identify basic components and metrics in the assessment of standalone CAD systems 2. Understand how each component may affect the assessed performance 3. Learn about AAPM CAD subcommittee's opinions and recommendations on factors and metrics related to the evaluation of standalone CAD system performance. © 2012 American Association of Physicists in Medicine.
Yousefi, Mina; Krzyżak, Adam; Suen, Ching Y
2018-05-01
Digital breast tomosynthesis (DBT) was developed in the field of breast cancer screening as a new tomographic technique to minimize the limitations of conventional digital mammography breast screening methods. A computer-aided detection (CAD) framework for mass detection in DBT has been developed and is described in this paper. The proposed framework operates on a set of two-dimensional (2D) slices. With plane-to-plane analysis on corresponding 2D slices from each DBT, it automatically learns complex patterns of 2D slices through a deep convolutional neural network (DCNN). It then applies multiple instance learning (MIL) with a randomized trees approach to classify DBT images based on extracted information from 2D slices. This CAD framework was developed and evaluated using 5040 2D image slices derived from 87 DBT volumes. The empirical results demonstrate that this proposed CAD framework achieves much better performance than CAD systems that use hand-crafted features and deep cardinality-restricted Bolzmann machines to detect masses in DBTs. Copyright © 2018 Elsevier Ltd. All rights reserved.
Evaluation of computer-aided detection and diagnosis systemsa)
Petrick, Nicholas; Sahiner, Berkman; Armato, Samuel G.; Bert, Alberto; Correale, Loredana; Delsanto, Silvia; Freedman, Matthew T.; Fryd, David; Gur, David; Hadjiiski, Lubomir; Huo, Zhimin; Jiang, Yulei; Morra, Lia; Paquerault, Sophie; Raykar, Vikas; Samuelson, Frank; Summers, Ronald M.; Tourassi, Georgia; Yoshida, Hiroyuki; Zheng, Bin; Zhou, Chuan; Chan, Heang-Ping
2013-01-01
Computer-aided detection and diagnosis (CAD) systems are increasingly being used as an aid by clinicians for detection and interpretation of diseases. Computer-aided detection systems mark regions of an image that may reveal specific abnormalities and are used to alert clinicians to these regions during image interpretation. Computer-aided diagnosis systems provide an assessment of a disease using image-based information alone or in combination with other relevant diagnostic data and are used by clinicians as a decision support in developing their diagnoses. While CAD systems are commercially available, standardized approaches for evaluating and reporting their performance have not yet been fully formalized in the literature or in a standardization effort. This deficiency has led to difficulty in the comparison of CAD devices and in understanding how the reported performance might translate into clinical practice. To address these important issues, the American Association of Physicists in Medicine (AAPM) formed the Computer Aided Detection in Diagnostic Imaging Subcommittee (CADSC), in part, to develop recommendations on approaches for assessing CAD system performance. The purpose of this paper is to convey the opinions of the AAPM CADSC members and to stimulate the development of consensus approaches and “best practices” for evaluating CAD systems. Both the assessment of a standalone CAD system and the evaluation of the impact of CAD on end-users are discussed. It is hoped that awareness of these important evaluation elements and the CADSC recommendations will lead to further development of structured guidelines for CAD performance assessment. Proper assessment of CAD system performance is expected to increase the understanding of a CAD system's effectiveness and limitations, which is expected to stimulate further research and development efforts on CAD technologies, reduce problems due to improper use, and eventually improve the utility and efficacy of CAD in clinical practice. PMID:23927365
Samala, Ravi K; Chan, Heang-Ping; Hadjiiski, Lubomir; Helvie, Mark A; Wei, Jun; Cha, Kenny
2016-12-01
Develop a computer-aided detection (CAD) system for masses in digital breast tomosynthesis (DBT) volume using a deep convolutional neural network (DCNN) with transfer learning from mammograms. A data set containing 2282 digitized film and digital mammograms and 324 DBT volumes were collected with IRB approval. The mass of interest on the images was marked by an experienced breast radiologist as reference standard. The data set was partitioned into a training set (2282 mammograms with 2461 masses and 230 DBT views with 228 masses) and an independent test set (94 DBT views with 89 masses). For DCNN training, the region of interest (ROI) containing the mass (true positive) was extracted from each image. False positive (FP) ROIs were identified at prescreening by their previously developed CAD systems. After data augmentation, a total of 45 072 mammographic ROIs and 37 450 DBT ROIs were obtained. Data normalization and reduction of non-uniformity in the ROIs across heterogeneous data was achieved using a background correction method applied to each ROI. A DCNN with four convolutional layers and three fully connected (FC) layers was first trained on the mammography data. Jittering and dropout techniques were used to reduce overfitting. After training with the mammographic ROIs, all weights in the first three convolutional layers were frozen, and only the last convolution layer and the FC layers were randomly initialized again and trained using the DBT training ROIs. The authors compared the performances of two CAD systems for mass detection in DBT: one used the DCNN-based approach and the other used their previously developed feature-based approach for FP reduction. The prescreening stage was identical in both systems, passing the same set of mass candidates to the FP reduction stage. For the feature-based CAD system, 3D clustering and active contour method was used for segmentation; morphological, gray level, and texture features were extracted and merged with a linear discriminant classifier to score the detected masses. For the DCNN-based CAD system, ROIs from five consecutive slices centered at each candidate were passed through the trained DCNN and a mass likelihood score was generated. The performances of the CAD systems were evaluated using free-response ROC curves and the performance difference was analyzed using a non-parametric method. Before transfer learning, the DCNN trained only on mammograms with an AUC of 0.99 classified DBT masses with an AUC of 0.81 in the DBT training set. After transfer learning with DBT, the AUC improved to 0.90. For breast-based CAD detection in the test set, the sensitivity for the feature-based and the DCNN-based CAD systems was 83% and 91%, respectively, at 1 FP/DBT volume. The difference between the performances for the two systems was statistically significant (p-value < 0.05). The image patterns learned from the mammograms were transferred to the mass detection on DBT slices through the DCNN. This study demonstrated that large data sets collected from mammography are useful for developing new CAD systems for DBT, alleviating the problem and effort of collecting entirely new large data sets for the new modality.
Computer-aided detection (CAD) of breast cancer on full field digital and screening film mammograms
NASA Astrophysics Data System (ADS)
Sun, Xuejun; Qian, Wei; Song, Xiaoshan; Qian, Yuyan; Song, Dansheng; Clark, Robert A.
2003-05-01
Full-field digital mammography (FFDM) as a new breast imaging modality has potential to detect more breast cancers or to detect them at smaller sizes and earlier stages compared with screening film mammography (SFM). However, its performance needs verification, and it would pose new problems for the development of CAD methods for breast cancer detection and diagnosis. Performance evaluation of CAD systems on FFDM and SFM has been conducted in this study, respectively. First, an adaptive CAD system employing a series of advanced modules has been developed on FFDM. Second, a standardization approach has been developed to make the CAD system independent of characteristics of digitizer or imaging modalities for mammography. CAD systems developed previously for SFM and developed in this study for FFDM have been evaluated on FFDM and SFM images without and with standardization, respectively, to examine the performance improvement of the CAD system developed in this study. Computerized free-response receiver operating characteristic (FROC) analysis has been adopted as performance evaluation method. Compared with previous one, the CAD system developed in this study demonstrated significantly performance improvements. However, the comparison results have shown that the performances of final CAD system in this study are not significantly different on FFDM and on SFM after standardization. It needs further study on the assessment of CAD system performance on FFDM and SFM modalities.
Drew, Trafton; Cunningham, Corbin; Wolfe, Jeremy
2012-01-01
Rational and Objectives Computer Aided Detection (CAD) systems are intended to improve performance. This study investigates how CAD might actually interfere with a visual search task. This is a laboratory study with implications for clinical use of CAD. Methods 47 naïve observers in two studies were asked to search for a target, embedded in 1/f2.4 noise while we monitored their eye-movements. For some observers, a CAD system marked 75% of targets and 10% of distractors while other observers completed the study without CAD. In Experiment 1, the CAD system’s primary function was to tell observers where the target might be. In Experiment 2, CAD provided information about target identity. Results In Experiment 1, there was a significant enhancement of observer sensitivity in the presence of CAD (t(22)=4.74, p<.001), but there was also a substantial cost. Targets that were not marked by the CAD system were missed more frequently than equivalent targets in No CAD blocks of the experiment (t(22)=7.02, p<.001). Experiment 2 showed no behavioral benefit from CAD, but also no significant cost on sensitivity to unmarked targets (t(22)=0.6, p=n.s.). Finally, in both experiments, CAD produced reliable changes in eye-movements: CAD observers examined a lower total percentage of the search area than the No CAD observers (Ex 1: t(48)=3.05, p<.005; Ex 2: t(50)=7.31, p<.001). Conclusions CAD signals do not combine with observers’ unaided performance in a straight-forward manner. CAD can engender a sense of certainty that can lead to incomplete search and elevated chances of missing unmarked stimuli. PMID:22958720
Berry, Colin; Corcoran, David; Hennigan, Barry; Watkins, Stuart; Layland, Jamie; Oldroyd, Keith G.
2015-01-01
Coronary artery disease (CAD) is a leading global cause of morbidity and mortality, and improvements in the diagnosis and treatment of CAD can reduce the health and economic burden of this condition. Fractional flow reserve (FFR) is an evidence-based diagnostic test of the physiological significance of a coronary artery stenosis. Fractional flow reserve is a pressure-derived index of the maximal achievable myocardial blood flow in the presence of an epicardial coronary stenosis as a ratio to maximum achievable flow if that artery were normal. When compared with standard angiography-guided management, FFR disclosure is impactful on the decision for revascularization and clinical outcomes. In this article, we review recent developments with FFR in patients with stable CAD and recent myocardial infarction. Specifically, we review novel developments in our understanding of CAD pathophysiology, diagnostic applications, prognostic studies, clinical trials, and clinical guidelines. PMID:26038588
Path length entropy analysis of diastolic heart sounds.
Griffel, Benjamin; Zia, Mohammad K; Fridman, Vladamir; Saponieri, Cesare; Semmlow, John L
2013-09-01
Early detection of coronary artery disease (CAD) using the acoustic approach, a noninvasive and cost-effective method, would greatly improve the outcome of CAD patients. To detect CAD, we analyze diastolic sounds for possible CAD murmurs. We observed diastolic sounds to exhibit 1/f structure and developed a new method, path length entropy (PLE) and a scaled version (SPLE), to characterize this structure to improve CAD detection. We compare SPLE results to Hurst exponent, Sample entropy and Multiscale entropy for distinguishing between normal and CAD patients. SPLE achieved a sensitivity-specificity of 80%-81%, the best of the tested methods. However, PLE and SPLE are not sufficient to prove nonlinearity, and evaluation using surrogate data suggests that our cardiovascular sound recordings do not contain significant nonlinear properties. Copyright © 2013 Elsevier Ltd. All rights reserved.
Path Length Entropy Analysis of Diastolic Heart Sounds
Griffel, B.; Zia, M. K.; Fridman, V.; Saponieri, C.; Semmlow, J. L.
2013-01-01
Early detection of coronary artery disease (CAD) using the acoustic approach, a noninvasive and cost-effective method, would greatly improve the outcome of CAD patients. To detect CAD, we analyze diastolic sounds for possible CAD murmurs. We observed diastolic sounds to exhibit 1/f structure and developed a new method, path length entropy (PLE) and a scaled version (SPLE), to characterize this structure to improve CAD detection. We compare SPLE results to Hurst exponent, Sample entropy and Multi-scale entropy for distinguishing between normal and CAD patients. SPLE achieved a sensitivity-specificity of 80%–81%, the best of the tested methods. However, PLE and SPLE are not sufficient to prove nonlinearity, and evaluation using surrogate data suggests that our cardiovascular sound recordings do not contain significant nonlinear properties. PMID:23930808
Gao, Luying; Liu, Ruyu; Jiang, Yuxin; Song, Wenfeng; Wang, Ying; Liu, Jia; Wang, Juanjuan; Wu, Dongqian; Li, Shuai; Hao, Aimin; Zhang, Bo
2018-04-01
The purpose of this study was to compare the diagnostic efficiency of a thyroid ultrasound computer-aided diagnosis (CAD) system with that of 1 radiologist. This study retrospectively reviewed 342 surgically resected thyroid nodules from July 2013 to December 2013 at our center. The nodules were assessed on typical ultrasound images using the CAD system and reviewed by 1 experienced radiologist. The radiologist stratified the risk of malignancy using the Thyroid Imaging Reporting and Data Systems (TIRADS) and the American Thyroid Association (ATA) guidelines. The radiologist, using TI-RADS and ATA guidelines, performed better than the CAD system (P < .01). The sensitivity of the CAD system was similar to that of an experienced radiologist (P > .05; P < .01; and P > .05). However, we found that the CAD system had lower specificity (P < .01). The sensitivity of a thyroid ultrasound CAD system in differentiating nodules was similar to that of an experienced radiologist. However, the CAD system had lower specificity. © 2017 Wiley Periodicals, Inc.
Analog Computer-Aided Detection (CAD) information can be more effective than binary marks.
Cunningham, Corbin A; Drew, Trafton; Wolfe, Jeremy M
2017-02-01
In socially important visual search tasks, such as baggage screening and diagnostic radiology, experts miss more targets than is desirable. Computer-aided detection (CAD) programs have been developed specifically to improve performance in these professional search tasks. For example, in breast cancer screening, many CAD systems are capable of detecting approximately 90% of breast cancer, with approximately 0.5 false-positive detections per image. Nevertheless, benefits of CAD in clinical settings tend to be small (Birdwell, 2009) or even absent (Meziane et al., 2011; Philpotts, 2009). The marks made by a CAD system can be "binary," giving the same signal to any location where the signal is above some threshold. Alternatively, a CAD system presents an analog signal that reflects strength of the signal at a location. In the experiments reported, we compare analog and binary CAD presentations using nonexpert observers and artificial stimuli defined by two noisy signals: a visible color signal and an "invisible" signal that informed our simulated CAD system. We found that analog CAD generally yielded better overall performance than binary CAD. The analog benefit is similar at high and low target prevalence. Our data suggest that the form of the CAD signal can directly influence performance. Analog CAD may allow the computer to be more helpful to the searcher.
NASA Astrophysics Data System (ADS)
Park, Sang Cheol; Zheng, Bin; Wang, Xiao-Hui; Gur, David
2008-03-01
Digital breast tomosynthesis (DBT) has emerged as a promising imaging modality for screening mammography. However, visually detecting micro-calcification clusters depicted on DBT images is a difficult task. Computer-aided detection (CAD) schemes for detecting micro-calcification clusters depicted on mammograms can achieve high performance and the use of CAD results can assist radiologists in detecting subtle micro-calcification clusters. In this study, we compared the performance of an available 2D based CAD scheme with one that includes a new grouping and scoring method when applied to both projection and reconstructed DBT images. We selected a dataset involving 96 DBT examinations acquired on 45 women. Each DBT image set included 11 low dose projection images and a varying number of reconstructed image slices ranging from 18 to 87. In this dataset 20 true-positive micro-calcification clusters were visually detected on the projection images and 40 were visually detected on the reconstructed images, respectively. We first applied the CAD scheme that was previously developed in our laboratory to the DBT dataset. We then tested a new grouping method that defines an independent cluster by grouping the same cluster detected on different projection or reconstructed images. We then compared four scoring methods to assess the CAD performance. The maximum sensitivity level observed for the different grouping and scoring methods were 70% and 88% for the projection and reconstructed images with a maximum false-positive rate of 4.0 and 15.9 per examination, respectively. This preliminary study demonstrates that (1) among the maximum, the minimum or the average CAD generated scores, using the maximum score of the grouped cluster regions achieved the highest performance level, (2) the histogram based scoring method is reasonably effective in reducing false-positive detections on the projection images but the overall CAD sensitivity is lower due to lower signal-to-noise ratio, and (3) CAD achieved higher sensitivity and higher false-positive rate (per examination) on the reconstructed images. We concluded that without changing the detection threshold or performing pre-filtering to possibly increase detection sensitivity, current CAD schemes developed and optimized for 2D mammograms perform relatively poorly and need to be re-optimized using DBT datasets and new grouping and scoring methods need to be incorporated into the schemes if these are to be used on the DBT examinations.
Trainer, Asa; Hedberg, Thomas; Feeney, Allison Barnard; Fischer, Kevin; Rosche, Phil
2016-01-01
Advances in information technology triggered a digital revolution that holds promise of reduced costs, improved productivity, and higher quality. To ride this wave of innovation, manufacturing enterprises are changing how product definitions are communicated - from paper to models. To achieve industry's vision of the Model-Based Enterprise (MBE), the MBE strategy must include model-based data interoperability from design to manufacturing and quality in the supply chain. The Model-Based Definition (MBD) is created by the original equipment manufacturer (OEM) using Computer-Aided Design (CAD) tools. This information is then shared with the supplier so that they can manufacture and inspect the physical parts. Today, suppliers predominantly use Computer-Aided Manufacturing (CAM) and Coordinate Measuring Machine (CMM) models for these tasks. Traditionally, the OEM has provided design data to the supplier in the form of two-dimensional (2D) drawings, but may also include a three-dimensional (3D)-shape-geometry model, often in a standards-based format such as ISO 10303-203:2011 (STEP AP203). The supplier then creates the respective CAM and CMM models and machine programs to produce and inspect the parts. In the MBE vision for model-based data exchange, the CAD model must include product-and-manufacturing information (PMI) in addition to the shape geometry. Today's CAD tools can generate models with embedded PMI. And, with the emergence of STEP AP242, a standards-based model with embedded PMI can now be shared downstream. The on-going research detailed in this paper seeks to investigate three concepts. First, that the ability to utilize a STEP AP242 model with embedded PMI for CAD-to-CAM and CAD-to-CMM data exchange is possible and valuable to the overall goal of a more efficient process. Second, the research identifies gaps in tools, standards, and processes that inhibit industry's ability to cost-effectively achieve model-based-data interoperability in the pursuit of the MBE vision. Finally, it also seeks to explore the interaction between CAD and CMM processes and determine if the concept of feedback from CAM and CMM back to CAD is feasible. The main goal of our study is to test the hypothesis that model-based-data interoperability from CAD-to-CAM and CAD-to-CMM is feasible through standards-based integration. This paper presents several barriers to model-based-data interoperability. Overall, the project team demonstrated the exchange of product definition data between CAD, CAM, and CMM systems using standards-based methods. While gaps in standards coverage were identified, the gaps should not stop industry's progress toward MBE. The results of our study provide evidence in support of an open-standards method to model-based-data interoperability, which would provide maximum value and impact to industry.
Bahari, Mahmoud; Savadi Oskoee, Siavash; Kimyai, Soodabeh; Pouralibaba, Firoz; Farhadi, Farrokh; Norouzi, Marouf
2014-01-01
Background and aims. The aim was to evaluate the effect of casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) on microtensile bond strength (μTBS) to carious affected dentin (CAD) using etch-and-rinse and self-etch adhesive systems. Materials and methods. The occlusal surface of 32 human molars with moderate occlusal caries was removed. Infected dentin was removed until reaching CAD and the teeth were randomly divided into two groups based on the Single Bond (SB) and Clearfil SE Bond (CSE) adhesive systems. Before composite resin bonding, each group was subdivided into three subgroups of ND, CAD and CPP-ACP-treated CAD (CAD-CPP) based on the dentin substrate. After dissecting samples to l-mm-thick cross-sections (each subgroup: n = 13), μTBS was measured at a strain rate of 0.5 mm/min. Data was analyzed using two-way ANOVA, independent samples t-test and post-hoc Tukey tests (α=0.05). Results. Bond strength of both adhesive systems to ND was significantly higher than that to CAD (P <0.001) and CAD/CPP (P < 0.001). There were no significant differences between the μTBS of SB to CAD and CAD-CPP (P > 0.05).μTBS of CSE to CAD-CPP was higher than that to CAD; however, the difference was not significant (P > 0.05). Significant differences were found between SB and CSE systems only with CAD substrate (P < 0.001). Conclusion. Regardless of the adhesive system used, surface treatment of CAD with CPP-ACP did not have a significant effect on bond strength. However, bond strength to CAD was higher with SB rather than with CSE. PMID:25346832
CAD/CAE Integration Enhanced by New CAD Services Standard
NASA Technical Reports Server (NTRS)
Claus, Russell W.
2002-01-01
A Government-industry team led by the NASA Glenn Research Center has developed a computer interface standard for accessing data from computer-aided design (CAD) systems. The Object Management Group, an international computer standards organization, has adopted this CAD services standard. The new standard allows software (e.g., computer-aided engineering (CAE) and computer-aided manufacturing software to access multiple CAD systems through one programming interface. The interface is built on top of a distributed computing system called the Common Object Request Broker Architecture (CORBA). CORBA allows the CAD services software to operate in a distributed, heterogeneous computing environment.
Analog Computer-Aided Detection (CAD) information can be more effective than binary marks
Cunningham, Corbin A.; Drew, Trafton; Wolfe, Jeremy M.
2017-01-01
In socially important visual search tasks such as baggage screening and diagnostic radiology, experts miss more targets than is desirable. Computer Aided Detection (CAD) programs have been developed specifically to help improve performance in these professional search tasks. For example, in breast cancer screening, many CAD systems are capable of detecting approximately 90% of breast cancer, with approximately 0.5 false positive detections per image. Nevertheless, benefits of CAD in clinical settings tend to be small (Birdwell, 2009) or even absent (Meziane et al., 2011; Philpotts, 2009). The marks made by a CAD system can be “Binary”, giving the same signal to any location where the signal is above some threshold. Alternatively, a CAD system present an Analog signal that reflected strength of the signal at a location. In the experiments reported here, we compare analog and binary CAD presentations using non-expert observers and artificial stimuli defined by two noisy signals: a visible color signal and an "invisible" signal that informed our simulated CAD system. We found that analog CAD generally yielded better overall performance than binary CAD. The analog benefit is similar at high and low target prevalence. Our data suggest that the form of the CAD signal can directly influence performance. Analog CAD may allow the computer to be more helpful to the searcher. PMID:27928658
Computer aided diagnosis based on medical image processing and artificial intelligence methods
NASA Astrophysics Data System (ADS)
Stoitsis, John; Valavanis, Ioannis; Mougiakakou, Stavroula G.; Golemati, Spyretta; Nikita, Alexandra; Nikita, Konstantina S.
2006-12-01
Advances in imaging technology and computer science have greatly enhanced interpretation of medical images, and contributed to early diagnosis. The typical architecture of a Computer Aided Diagnosis (CAD) system includes image pre-processing, definition of region(s) of interest, features extraction and selection, and classification. In this paper, the principles of CAD systems design and development are demonstrated by means of two examples. The first one focuses on the differentiation between symptomatic and asymptomatic carotid atheromatous plaques. For each plaque, a vector of texture and motion features was estimated, which was then reduced to the most robust ones by means of ANalysis of VAriance (ANOVA). Using fuzzy c-means, the features were then clustered into two classes. Clustering performances of 74%, 79%, and 84% were achieved for texture only, motion only, and combinations of texture and motion features, respectively. The second CAD system presented in this paper supports the diagnosis of focal liver lesions and is able to characterize liver tissue from Computed Tomography (CT) images as normal, hepatic cyst, hemangioma, and hepatocellular carcinoma. Five texture feature sets were extracted for each lesion, while a genetic algorithm based feature selection method was applied to identify the most robust features. The selected feature set was fed into an ensemble of neural network classifiers. The achieved classification performance was 100%, 93.75% and 90.63% in the training, validation and testing set, respectively. It is concluded that computerized analysis of medical images in combination with artificial intelligence can be used in clinical practice and may contribute to more efficient diagnosis.
Suzuki, Kenji
2009-09-21
Computer-aided diagnosis (CAD) has been an active area of study in medical image analysis. A filter for the enhancement of lesions plays an important role for improving the sensitivity and specificity in CAD schemes. The filter enhances objects similar to a model employed in the filter; e.g. a blob-enhancement filter based on the Hessian matrix enhances sphere-like objects. Actual lesions, however, often differ from a simple model; e.g. a lung nodule is generally modeled as a solid sphere, but there are nodules of various shapes and with internal inhomogeneities such as a nodule with spiculations and ground-glass opacity. Thus, conventional filters often fail to enhance actual lesions. Our purpose in this study was to develop a supervised filter for the enhancement of actual lesions (as opposed to a lesion model) by use of a massive-training artificial neural network (MTANN) in a CAD scheme for detection of lung nodules in CT. The MTANN filter was trained with actual nodules in CT images to enhance actual patterns of nodules. By use of the MTANN filter, the sensitivity and specificity of our CAD scheme were improved substantially. With a database of 69 lung cancers, nodule candidate detection by the MTANN filter achieved a 97% sensitivity with 6.7 false positives (FPs) per section, whereas nodule candidate detection by a difference-image technique achieved a 96% sensitivity with 19.3 FPs per section. Classification-MTANNs were applied for further reduction of the FPs. The classification-MTANNs removed 60% of the FPs with a loss of one true positive; thus, it achieved a 96% sensitivity with 2.7 FPs per section. Overall, with our CAD scheme based on the MTANN filter and classification-MTANNs, an 84% sensitivity with 0.5 FPs per section was achieved.
Chan, Heang-Ping; Hadjiiski, Lubomir; Helvie, Mark A.; Wei, Jun; Cha, Kenny
2016-01-01
Purpose: Develop a computer-aided detection (CAD) system for masses in digital breast tomosynthesis (DBT) volume using a deep convolutional neural network (DCNN) with transfer learning from mammograms. Methods: A data set containing 2282 digitized film and digital mammograms and 324 DBT volumes were collected with IRB approval. The mass of interest on the images was marked by an experienced breast radiologist as reference standard. The data set was partitioned into a training set (2282 mammograms with 2461 masses and 230 DBT views with 228 masses) and an independent test set (94 DBT views with 89 masses). For DCNN training, the region of interest (ROI) containing the mass (true positive) was extracted from each image. False positive (FP) ROIs were identified at prescreening by their previously developed CAD systems. After data augmentation, a total of 45 072 mammographic ROIs and 37 450 DBT ROIs were obtained. Data normalization and reduction of non-uniformity in the ROIs across heterogeneous data was achieved using a background correction method applied to each ROI. A DCNN with four convolutional layers and three fully connected (FC) layers was first trained on the mammography data. Jittering and dropout techniques were used to reduce overfitting. After training with the mammographic ROIs, all weights in the first three convolutional layers were frozen, and only the last convolution layer and the FC layers were randomly initialized again and trained using the DBT training ROIs. The authors compared the performances of two CAD systems for mass detection in DBT: one used the DCNN-based approach and the other used their previously developed feature-based approach for FP reduction. The prescreening stage was identical in both systems, passing the same set of mass candidates to the FP reduction stage. For the feature-based CAD system, 3D clustering and active contour method was used for segmentation; morphological, gray level, and texture features were extracted and merged with a linear discriminant classifier to score the detected masses. For the DCNN-based CAD system, ROIs from five consecutive slices centered at each candidate were passed through the trained DCNN and a mass likelihood score was generated. The performances of the CAD systems were evaluated using free-response ROC curves and the performance difference was analyzed using a non-parametric method. Results: Before transfer learning, the DCNN trained only on mammograms with an AUC of 0.99 classified DBT masses with an AUC of 0.81 in the DBT training set. After transfer learning with DBT, the AUC improved to 0.90. For breast-based CAD detection in the test set, the sensitivity for the feature-based and the DCNN-based CAD systems was 83% and 91%, respectively, at 1 FP/DBT volume. The difference between the performances for the two systems was statistically significant (p-value < 0.05). Conclusions: The image patterns learned from the mammograms were transferred to the mass detection on DBT slices through the DCNN. This study demonstrated that large data sets collected from mammography are useful for developing new CAD systems for DBT, alleviating the problem and effort of collecting entirely new large data sets for the new modality. PMID:27908154
Computer science, artificial intelligence, and cybernetics: Applied artificial intelligence in Japan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rubinger, B.
1988-01-01
This sourcebook provides information on the developments in artificial intelligence originating in Japan. Spanning such innovations as software productivity, natural language processing, CAD, and parallel inference machines, this volume lists leading organizations conducting research or implementing AI systems, describes AI applications being pursued, illustrates current results achieved, and highlights sources reporting progress.
A hybrid model for automatic identification of risk factors for heart disease.
Yang, Hui; Garibaldi, Jonathan M
2015-12-01
Coronary artery disease (CAD) is the leading cause of death in both the UK and worldwide. The detection of related risk factors and tracking their progress over time is of great importance for early prevention and treatment of CAD. This paper describes an information extraction system that was developed to automatically identify risk factors for heart disease in medical records while the authors participated in the 2014 i2b2/UTHealth NLP Challenge. Our approaches rely on several nature language processing (NLP) techniques such as machine learning, rule-based methods, and dictionary-based keyword spotting to cope with complicated clinical contexts inherent in a wide variety of risk factors. Our system achieved encouraging performance on the challenge test data with an overall micro-averaged F-measure of 0.915, which was competitive to the best system (F-measure of 0.927) of this challenge task. Copyright © 2015 Elsevier Inc. All rights reserved.
Genetic loci associated with nonobstructive coronary artery disease in Caucasian women.
Weng, Liming; Taylor, Kent D; Chen, Yii-Der Ida; Sopko, George; Kelsey, Sheryl F; Bairey Merz, C Noel; Pepine, Carl J; Miller, Virginia M; Rotter, Jerome I; Gulati, Martha; Goodarzi, Mark O; Cooper-DeHoff, Rhonda M
2016-01-01
Nonobstructive coronary artery disease (CAD) in women is associated with adverse cardiovascular (CV) outcomes; however, information regarding genetic variants that predispose women to nonobstructive CAD is lacking. Women from the Women's Ischemia Syndrome Evaluation (WISE) Study and the St. James Women Take Heart (WTH) Study were genotyped with the Cardio-MetaboChip. WISE enrolled women with symptoms and signs of ischemia referred for coronary angiography; WTH enrolled asymptomatic, community-based women without heart disease. Analyses were conducted with a case (WISE)--control (WTH) design and multivariate logistic regression models to investigate genetic variation associated with likelihood of nonobstructive CAD. One genetic marker, single nucleotide polymorphism (SNP) rs2301753 on chromosome 6 in RNF39, achieved chip-wide significance for nonobstructive CAD (P < 9.5 × 10(-7)). After adjusting for baseline characteristics, we found no variants achieved chip-wide significance. However, SNP rs2301753 on chromosome 6 in RNF39 was associated with reduced likelihood of nonobstructive CAD [odds ratio (OR) 0.42 and 95% confidence interval (CI) of 0.29 to 0.68], at a nominal level of P = 5.6 × 10(-6), while SNP rs12818945 in the ATP2B1 locus on chromosome 12 was associated with increased odds for nonobstructive CAD (OR 2.38 and 95% CI of 1.63 to 3.45) and nominal P = 5.8 × 10(-6). The functions of RNF39 and ATP2B1 raise the possibility that genes involved in cardio-dysfunction may contribute to nonobstructive CAD in Caucasian women and may provide insights into novel approaches for therapy and prevention. If replicated, incorporation of these genetic variants into diagnostic evaluation may identify women at high risk for nonobstructive CAD.
Investigation of IGES for CAD/CAE data transfer
NASA Technical Reports Server (NTRS)
Zobrist, George W.
1989-01-01
In a CAD/CAE facility there is always the possibility that one may want to transfer the design graphics database from the native system to a non-native system. This may occur because of dissimilar systems within an organization or a new CAD/CAE system is to be purchased. The Initial Graphics Exchange Specification (IGES) was developed in an attempt to solve this scenario. IGES is a neutral database format into which the CAD/CAE native database format can be translated to and from. Translating the native design database format to IGES requires a pre-processor and transling from IGES to the native database format requires a post-processor. IGES is an artifice to represent CAD/CAE product data in a neutral environment to allow interfacing applications, archive the database, interchange of product data between dissimilar CAD/CAE systems, and other applications. The intent here is to present test data on translating design product data from a CAD/CAE system to itself and to translate data initially prepared in IGES format to various native design formats. This information can be utilized in planning potential procurement and developing a design discipline within the CAD/CAE community.
A CAD System for Hemorrhagic Stroke.
Nowinski, Wieslaw L; Qian, Guoyu; Hanley, Daniel F
2014-09-01
Computer-aided detection/diagnosis (CAD) is a key component of routine clinical practice, increasingly used for detection, interpretation, quantification and decision support. Despite a critical need, there is no clinically accepted CAD system for stroke yet. Here we introduce a CAD system for hemorrhagic stroke. This CAD system segments, quantifies, and displays hematoma in 2D/3D, and supports evacuation of hemorrhage by thrombolytic treatment monitoring progression and quantifying clot removal. It supports seven-step workflow: select patient, add a new study, process patient's scans, show segmentation results, plot hematoma volumes, show 3D synchronized time series hematomas, and generate report. The system architecture contains four components: library, tools, application with user interface, and hematoma segmentation algorithm. The tools include a contour editor, 3D surface modeler, 3D volume measure, histogramming, hematoma volume plot, and 3D synchronized time-series hematoma display. The CAD system has been designed and implemented in C++. It has also been employed in the CLEAR and MISTIE phase-III, multicenter clinical trials. This stroke CAD system is potentially useful in research and clinical applications, particularly for clinical trials.
Computer-aided design development transition for IPAD environment
NASA Technical Reports Server (NTRS)
Owens, H. G.; Mock, W. D.; Mitchell, J. C.
1980-01-01
The relationship of federally sponsored computer-aided design/computer-aided manufacturing (CAD/CAM) programs to the aircraft life cycle design process, an overview of NAAD'S CAD development program, an evaluation of the CAD design process, a discussion of the current computing environment within which NAAD is developing its CAD system, some of the advantages/disadvantages of the NAAD-IPAD approach, and CAD developments during transition into the IPAD system are discussed.
Computer Aided Drafting. Instructor's Guide.
ERIC Educational Resources Information Center
Henry, Michael A.
This guide is intended for use in introducing students to the operation and applications of computer-aided drafting (CAD) systems. The following topics are covered in the individual lessons: understanding CAD (CAD versus traditional manual drafting and care of software and hardware); using the components of a CAD system (primary and other input…
Kao, E-Fong; Liu, Gin-Chung; Lee, Lo-Yeh; Tsai, Huei-Yi; Jaw, Twei-Shiun
2015-06-01
The ability to give high priority to examinations with pathological findings could be very useful to radiologists with large work lists who wish to first evaluate the most critical studies. A computer-aided detection (CAD) system for identifying chest examinations with abnormalities has therefore been developed. To evaluate the effectiveness of a CAD system on report turnaround times of chest examinations with abnormalities. The CAD system was designed to automatically mark chest examinations with possible abnormalities in the work list of radiologists interpreting chest examinations. The system evaluation was performed in two phases: two radiologists interpreted the chest examinations without CAD in phase 1 and with CAD in phase 2. The time information recorded by the radiology information system was then used to calculate the turnaround times. All chest examinations were reviewed by two other radiologists and were divided into normal and abnormal groups. The turnaround times for the examinations with pathological findings with and without the CAD system assistance were compared. The sensitivity and specificity of the CAD for chest abnormalities were 0.790 and 0.697, respectively, and use of the CAD system decreased the turnaround time for chest examinations with abnormalities by 44%. The turnaround times required for radiologists to identify chest examinations with abnormalities could be reduced by using the CAD system. This system could be useful for radiologists with large work lists who wish to first evaluate the most critical studies. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
A Step-by-Step Conservative Approach for CAD-CAM Laminate Veneers
Henríquez Gutiérrez, Ismael; Guzmán Marusic, Álvaro; Báez Rosales, Abelardo; Tisi Lanchares, José Pablo
2017-01-01
The use of CAD/CAM technology has allowed the fabrication of ceramic restorations efficiently and with predictable results. Lithium disilicate is a type of glass ceramic material that can be used for the elaboration of laminate veneers, being monolithic restorations which require characterization through a covering ceramic in order to achieve acceptable esthetic results. The next case report shows a predictable clinical protocol for the rehabilitation of the anterior teeth through the preparation of CAD/CAM veneers (e.max CAD, Ivoclar Vivadent, Liechtenstein) which have been characterized by a nanofluorapatite ceramic (e.max Ceram, Ivoclar Vivadent, Liechtenstein) through the layering technique. PMID:28884029
Repairability of CAD/CAM high-density PMMA- and composite-based polymers.
Wiegand, Annette; Stucki, Lukas; Hoffmann, Robin; Attin, Thomas; Stawarczyk, Bogna
2015-11-01
The study aimed to analyse the shear bond strength of computer-aided design and computer-aided manufacturing (CAD/CAM) polymethyl methacrylate (PMMA)- and composite-based polymer materials repaired with a conventional methacrylate-based composite after different surface pretreatments. Each 48 specimens was prepared from six different CAD/CAM polymer materials (Ambarino high-class, artBloc Temp, CAD-Temp, Lava Ultimate, Telio CAD, Everest C-Temp) and a conventional dimethacrylate-based composite (Filtek Supreme XTE, control) and aged by thermal cycling (5000 cycles, 5-55 °C). The surfaces were left untreated or were pretreated by mechanical roughening, aluminium oxide air abrasion or silica coating/silanization (each subgroup n = 12). The surfaces were further conditioned with an etch&rinse adhesive (OptiBond FL) before the repair composite (Filtek Supreme XTE) was adhered to the surface. After further thermal cycling, shear bond strength was tested, and failure modes were assessed. Shear bond strength was statistically analysed by two- and one-way ANOVAs and Weibull statistics, failure mode by chi(2) test (p ≤ 0.05). Shear bond strength was highest for silica coating/silanization > aluminium oxide air abrasion = mechanical roughening > no surface pretreatment. Independently of the repair pretreatment, highest bond strength values were observed in the control group and for the composite-based Everest C-Temp and Ambarino high-class, while PMMA-based materials (artBloc Temp, CAD-Temp and Telio CAD) presented significantly lowest values. For all materials, repair without any surface pretreatment resulted in adhesive failures only, which mostly were reduced when surface pretreatment was performed. Repair of CAD/CAM high-density polymers requires surface pretreatment prior to adhesive and composite application. However, four out of six of the tested CAD/CAM materials did not achieve the repair bond strength of a conventional dimethacrylate-based composite. Repair of PMMA- and composite-based polymers can be achieved by surface pretreatment followed by application of an adhesive and a conventional methacrylate-based composite.
A deep-learning based automatic pulmonary nodule detection system
NASA Astrophysics Data System (ADS)
Zhao, Yiyuan; Zhao, Liang; Yan, Zhennan; Wolf, Matthias; Zhan, Yiqiang
2018-02-01
Lung cancer is the deadliest cancer worldwide. Early detection of lung cancer is a promising way to lower the risk of dying. Accurate pulmonary nodule detection in computed tomography (CT) images is crucial for early diagnosis of lung cancer. The development of computer-aided detection (CAD) system of pulmonary nodules contributes to making the CT analysis more accurate and with more efficiency. Recent studies from other groups have been focusing on lung cancer diagnosis CAD system by detecting medium to large nodules. However, to fully investigate the relevance between nodule features and cancer diagnosis, a CAD that is capable of detecting nodules with all sizes is needed. In this paper, we present a deep-learning based automatic all size pulmonary nodule detection system by cascading two artificial neural networks. We firstly use a U-net like 3D network to generate nodule candidates from CT images. Then, we use another 3D neural network to refine the locations of the nodule candidates generated from the previous subsystem. With the second sub-system, we bring the nodule candidates closer to the center of the ground truth nodule locations. We evaluate our system on a public CT dataset provided by the Lung Nodule Analysis (LUNA) 2016 grand challenge. The performance on the testing dataset shows that our system achieves 90% sensitivity with an average of 4 false positives per scan. This indicates that our system can be an aid for automatic nodule detection, which is beneficial for lung cancer diagnosis.
Software Tools for Shipbuilding Productivity
1984-12-01
shipbuilding, is that design, manufacturing and robotic technology applications to shipbuilding have been proven. all aspects of shipbuilding is now a task...technical information about the process of Computer Aided Design (CAD) and Computer Aided Manufacturing (CAM) effectively has been a problem of serious and...Design (CAD) 3.4.1 CAD System Components 3.4.2 CAD System Benefits 3.4.3 New and Future CAD Technologies Computer Aided Manufacturing (CAM) 3.5.1 CAM
NASA Astrophysics Data System (ADS)
Land, Walker H., Jr.; Anderson, Frances; Smith, Tom; Fahlbusch, Stephen; Choma, Robert; Wong, Lut
2005-04-01
Achieving consistent and correct database cases is crucial to the correct evaluation of any computer-assisted diagnostic (CAD) paradigm. This paper describes the application of artificial intelligence (AI), knowledge engineering (KE) and knowledge representation (KR) to a data set of ~2500 cases from six separate hospitals, with the objective of removing/reducing inconsistent outlier data. Several support vector machine (SVM) kernels were used to measure diagnostic performance of the original and a "cleaned" data set. Specifically, KE and ER principles were applied to the two data sets which were re-examined with respect to the environment and agents. One data set was found to contain 25 non-characterizable sets. The other data set contained 180 non-characterizable sets. CAD system performance was measured with both the original and "cleaned" data sets using two SVM kernels as well as a multivariate probabilistic neural network (PNN). Results demonstrated: (i) a 10% average improvement in overall Az and (ii) approximately a 50% average improvement in partial Az.
21 CFR 872.3661 - Optical Impression Systems for CAD/CAM.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Optical Impression Systems for CAD/CAM. 872.3661... (CAD/CAM) is a device used to record the topographical characteristics of teeth, dental impressions, or... Design and Manufacturing (CAD/CAM) of Dental Restorations; Guidance for Industry and FDA.” For the...
21 CFR 872.3661 - Optical Impression Systems for CAD/CAM.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Optical Impression Systems for CAD/CAM. 872.3661... (CAD/CAM) is a device used to record the topographical characteristics of teeth, dental impressions, or... Design and Manufacturing (CAD/CAM) of Dental Restorations; Guidance for Industry and FDA.” For the...
21 CFR 872.3661 - Optical Impression Systems for CAD/CAM.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Optical Impression Systems for CAD/CAM. 872.3661... (CAD/CAM) is a device used to record the topographical characteristics of teeth, dental impressions, or... Design and Manufacturing (CAD/CAM) of Dental Restorations; Guidance for Industry and FDA.” For the...
Trainer, Asa; Hedberg, Thomas; Feeney, Allison Barnard; Fischer, Kevin; Rosche, Phil
2017-01-01
Advances in information technology triggered a digital revolution that holds promise of reduced costs, improved productivity, and higher quality. To ride this wave of innovation, manufacturing enterprises are changing how product definitions are communicated – from paper to models. To achieve industry's vision of the Model-Based Enterprise (MBE), the MBE strategy must include model-based data interoperability from design to manufacturing and quality in the supply chain. The Model-Based Definition (MBD) is created by the original equipment manufacturer (OEM) using Computer-Aided Design (CAD) tools. This information is then shared with the supplier so that they can manufacture and inspect the physical parts. Today, suppliers predominantly use Computer-Aided Manufacturing (CAM) and Coordinate Measuring Machine (CMM) models for these tasks. Traditionally, the OEM has provided design data to the supplier in the form of two-dimensional (2D) drawings, but may also include a three-dimensional (3D)-shape-geometry model, often in a standards-based format such as ISO 10303-203:2011 (STEP AP203). The supplier then creates the respective CAM and CMM models and machine programs to produce and inspect the parts. In the MBE vision for model-based data exchange, the CAD model must include product-and-manufacturing information (PMI) in addition to the shape geometry. Today's CAD tools can generate models with embedded PMI. And, with the emergence of STEP AP242, a standards-based model with embedded PMI can now be shared downstream. The on-going research detailed in this paper seeks to investigate three concepts. First, that the ability to utilize a STEP AP242 model with embedded PMI for CAD-to-CAM and CAD-to-CMM data exchange is possible and valuable to the overall goal of a more efficient process. Second, the research identifies gaps in tools, standards, and processes that inhibit industry's ability to cost-effectively achieve model-based-data interoperability in the pursuit of the MBE vision. Finally, it also seeks to explore the interaction between CAD and CMM processes and determine if the concept of feedback from CAM and CMM back to CAD is feasible. The main goal of our study is to test the hypothesis that model-based-data interoperability from CAD-to-CAM and CAD-to-CMM is feasible through standards-based integration. This paper presents several barriers to model-based-data interoperability. Overall, the project team demonstrated the exchange of product definition data between CAD, CAM, and CMM systems using standards-based methods. While gaps in standards coverage were identified, the gaps should not stop industry's progress toward MBE. The results of our study provide evidence in support of an open-standards method to model-based-data interoperability, which would provide maximum value and impact to industry. PMID:28691120
Turnkey CAD/CAM systems' integration with IPAD systems
NASA Technical Reports Server (NTRS)
Blauth, R. E.
1980-01-01
Today's commercially available turnkey CAD/CAM systems provide a highly interactive environment, and support many specialized application functions for the design/drafting/manufacturing process. This paper presents an overview of several aerospace companies which have successfully integrated turnkey CAD/CAM systems with their own company wide engineering and manufacturing systems. It also includes a vendor's view of the benefits as well as the disadvantages of such integration efforts. Specific emphasis is placed upon the selection of standards for representing geometric engineering data and for communicating such information between different CAD/CAM systems.
IGES transformer and NURBS in grid generation
NASA Technical Reports Server (NTRS)
Yu, Tzu-Yi; Soni, Bharat K.
1993-01-01
In the field of Grid Generation and the CAD/CAM, there are numerous geometry output formats which require the designer to spend a great deal of time manipulating geometrical entities in order to achieve a useful sculptured geometrical description for grid generation. Also in this process, there is a danger of losing fidelity of the geometry under consideration. This stresses the importance of a standard geometry definition for the communication link between varying CAD/CAM and grid system. The IGES (Initial Graphics Exchange Specification) file is a widely used communication between CAD/CAM and the analysis tools. The scientists at NASA Research Centers - including NASA Ames, NASA Langley, NASA Lewis, NASA Marshall - have recognized this importance and, therefore, in 1992 they formed the committee of the 'NASA-IGES' which is the subset of the standard IGES. This committee stresses the importance and encourages the CFD community to use the standard IGES file for the interface between the CAD/CAM and CFD analysis. Also, two of the IGES entities -- the NURBS Curve (Entity 126) and NURBS Surface (Entity 128) -- which have many useful geometric properties -- like the convex hull property, local control property and affine invariance, also widely utilized analytical geometries can be accurately represented using NURBS. This is important in today grid generation tools because of the emphasis of the interactive design. To satisfy the geometry transformation between the CAD/CAM system and Grid Generation field, the CAGI (Computer Aided Geometry Design) developed, which include the Geometry Transformation, Geometry Manipulation and Geometry Generation as well as the user interface. This paper will present the successful development IGES file transformer and application of NURBS definition in the grid generation.
NASA Astrophysics Data System (ADS)
Wormanns, Dag; Beyer, Florian; Butzbach, Arnauld; Zierott, Livia; Heindel, Walter
2006-03-01
The purpose of the presented study was to determine the impact of two different CAD systems used as concur-rent reader for detection of actionable nodules (>4 mm) on the interpretation of chest CT scans during routine reporting. Fifty consecutive MDCT scans (1 mm or 1.25 mm slice thickness, 0.8 mm reconstruction increment) were se-lected from clinical routine. All cases were read by a resident and a staff radiologist, and a written report was available in the radiology information system (RIS). The RIS report mentioned at least one actionable pulmonary nodule in 18 cases (50%) and did not report any pulmonary nodule in the remaining 32 cases. Two different recent CAD systems were independently applied to the 50 CT scans as concurrent reader with two radiologists: Siemens LungCare NEV and MEDIAN CAD-Lung. Two radiologists independently reviewed the CAD results and determined if a CAD result was a true positive or a false positive finding. Patients were classified into two groups: in group A if at least one actionable nodule was detected and in group B if no actionable nodules were found. The effect of CAD on routine reporting was simulated as set union of the findings of routine reporting and CAD thus applying CAD as concurrent reader. According to the RIS report group A (patients with at least one actionable nodule) contained 18 cases (36% of all 50 cases), and group B contained 32 cases. Application of a CAD system as concurrent reader resulted in detec-tion of additional CT scans with actionable nodules and reclassification into group A in 16 resp. 18 cases (radi-ologist 1 resp. radiologist 2) with Siemens NEV and in 19 resp. 18 cases with MEDIAN CAD-Lung. In seven cases MEDIAN CAD-Lung and in four cases Siemens NEV reclassified a case into group A while the other CAD system missed the relevant finding. Sensitivity on a nodule (>4 mm) base was .45 for Siemens NEV and .55 for MEDIAN CAD-Lung; the difference was not yet significant (p=.077). In our study use of CAD as second reader in routine reporting doubled the percentage of patients with actionable nodules larger than 4 mm.
3D Displays And User Interface Design For A Radiation Therapy Treatment Planning CAD Tool
NASA Astrophysics Data System (ADS)
Mosher, Charles E.; Sherouse, George W.; Chaney, Edward L.; Rosenman, Julian G.
1988-06-01
The long term goal of the project described in this paper is to improve local tumor control through the use of computer-aided treatment design methods that can result in selection of better treatment plans compared with conventional planning methods. To this end, a CAD tool for the design of radiation treatment beams is described. Crucial to the effectiveness of this tool are high quality 3D display techniques. We have found that 2D and 3D display methods dramatically improve the comprehension of the complex spatial relationships between patient anatomy, radiation beams, and dose distributions. In order to take full advantage of these displays, an intuitive and highly interactive user interface was created. If the system is to be used by physicians unfamiliar with computer systems, it is essential that a user interface is incorporated that allows the user to navigate through each step of the design process in a manner similar to what they are used to. Compared with conventional systems, we believe our display and CAD tools will allow the radiotherapist to achieve more accurate beam targetting leading to a better radiation dose configuration to the tumor volume. This would result in a reduction of the dose to normal tissue.
Correlation coefficient based supervised locally linear embedding for pulmonary nodule recognition.
Wu, Panpan; Xia, Kewen; Yu, Hengyong
2016-11-01
Dimensionality reduction techniques are developed to suppress the negative effects of high dimensional feature space of lung CT images on classification performance in computer aided detection (CAD) systems for pulmonary nodule detection. An improved supervised locally linear embedding (SLLE) algorithm is proposed based on the concept of correlation coefficient. The Spearman's rank correlation coefficient is introduced to adjust the distance metric in the SLLE algorithm to ensure that more suitable neighborhood points could be identified, and thus to enhance the discriminating power of embedded data. The proposed Spearman's rank correlation coefficient based SLLE (SC(2)SLLE) is implemented and validated in our pilot CAD system using a clinical dataset collected from the publicly available lung image database consortium and image database resource initiative (LICD-IDRI). Particularly, a representative CAD system for solitary pulmonary nodule detection is designed and implemented. After a sequential medical image processing steps, 64 nodules and 140 non-nodules are extracted, and 34 representative features are calculated. The SC(2)SLLE, as well as SLLE and LLE algorithm, are applied to reduce the dimensionality. Several quantitative measurements are also used to evaluate and compare the performances. Using a 5-fold cross-validation methodology, the proposed algorithm achieves 87.65% accuracy, 79.23% sensitivity, 91.43% specificity, and 8.57% false positive rate, on average. Experimental results indicate that the proposed algorithm outperforms the original locally linear embedding and SLLE coupled with the support vector machine (SVM) classifier. Based on the preliminary results from a limited number of nodules in our dataset, this study demonstrates the great potential to improve the performance of a CAD system for nodule detection using the proposed SC(2)SLLE. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Kijima, Kumiko; Mita, Hajime; Kawakami, Mitsuyasu; Amada, Kei
2018-02-02
In the present study, we confirm that 2,4-dichlorophenoxyacetic acid (2,4-D) oxygenase from Sphingomonas agrestis 58-1 belongs to the family of Rieske non-heme iron aromatic ring-hydroxylating oxygenases, which comprise a core enzyme (oxygenase), ferredoxin, and oxidoreductase. It has previously been shown that cadAB genes are necessary for the conversion of 2,4-D to 2,4-dichlorophenol; however, the respective roles of ferredoxin and oxidoreductase in the 2,4-D oxygenase system from S. agrestis 58-1 remain unknown. Using nucleotide sequence analysis of the plasmid pCADAB1 from Sphingomonas sp. ERG5, which degrades 4-chloro-2-methylphenoxyacetic acid and 2,4-D, Nielsen et al. identified orf95, upstream of cadA, and orf98, downstream of cadB, which were predicted and designated as cadD (oxidoreductase) and cadC (ferredoxin), respectively (Nielsen et al., PLoS One, 8, 1-9, 2013). These designations were the result of sequence analysis; therefore, we constructed an expression system of CadABC and CadABCD in Escherichia coli and assayed their enzyme activities. Our findings indicate that CadC is essential for the activity of 2,4-D oxygenase and CadD promotes CadABC activity in recombinant E. coli cells. Copyright © 2018 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.
DOT National Transportation Integrated Search
2000-03-01
The Denver Regional Transportation District (RTD) acquired a CAD/AVL system that became fully operational in 1996. The CAD/AVL system added radio channels and covert alarms in buses, located vehicles in real time, and monitored schedule adherence. Th...
Gougoutas, Alexander J; Bastidas, Nicholas; Bartlett, Scott P; Jackson, Oksana
2015-12-01
Microvascular reconstruction of the pediatric mandible, particularly when necessitated by severe, congenital hypoplasia, presents a formidable challenge. Complex cases, however, may be simplified by computer-aided design/computer-aided manufacturing (CAD/CAM) assisted surgical planning. This series represents the senior authors' preliminary experiences with CAD/CAM assisted, microvascular reconstruction of the pediatric mandible. Presented are two patients with hemifacial/bifacial microsomia, both with profound mandibular hypoplasia, who underwent CAD/CAM assisted reconstruction of their mandibles with vascularized fibula flaps. Surgical techniques, CAD/CAM routines employed, complications, and long-term outcomes are reported. Successful mandibular reconstructions were achieved in both patients with centralization of their native mandibles and augmentation of deficient mandibular subunits. No long-term complications were observed. CAD/CAM technology can be utilized in pediatric mandibular reconstruction, and is particularly beneficial in cases of profound, congenital hypoplasia requiring extensive, multi-planar, bony reconstructions. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
On the Use of CAD-Native Predicates and Geometry in Surface Meshing
NASA Technical Reports Server (NTRS)
Aftosmis, M. J.
1999-01-01
Several paradigms for accessing CAD geometry during surface meshing for CFD are discussed. File translation, inconsistent geometry engines and non-native point construction are all identified as sources of non-robustness. The paper argues in favor of accessing CAD parts and assemblies in their native format, without translation, and for the use of CAD-native predicates and constructors in surface mesh generation. The discussion also emphasizes the importance of examining the computational requirements for exact evaluation of triangulation predicates during surface meshing. The native approach is demonstrated through an algorithm for the generation of closed manifold surface triangulations from CAD geometry. CAD parts and assemblies are used in their native format, and a part's native geometry engine is accessed through a modeler-independent application programming interface (API). In seeking a robust and fully automated procedure, the algorithm is based on a new physical space manifold triangulation technique specially developed to avoid robustness issues associated with poorly conditioned mappings. In addition, this approach avoids the usual ambiguities associated with floating-point predicate evaluation on constructed coordinate geometry in a mapped space. The technique is incremental, so that each new site improves the triangulation by some well defined quality measure. The algorithm terminates after achieving a prespecified measure of mesh quality and produces a triangulation such that no angle is less than a given angle bound, a or greater than pi - 2alpha. This result also sets bounds on the maximum vertex degree, triangle aspect-ratio and maximum stretching rate for the triangulation. In addition to the output triangulations for a variety of CAD parts, the discussion presents related theoretical results which assert the existence of such an angle bound, and demonstrate that maximum bounds of between 25 deg and 30 deg may be achieved in practice.
Papadiochou, Sofia; Pissiotis, Argirios L
2018-04-01
The comparative assessment of computer-aided design and computer-aided manufacturing (CAD-CAM) technology and other fabrication techniques pertaining to marginal adaptation should be documented. Limited evidence exists on the effect of restorative material on the performance of a CAD-CAM system relative to marginal adaptation. The purpose of this systematic review was to investigate whether the marginal adaptation of CAD-CAM single crowns, fixed dental prostheses, and implant-retained fixed dental prostheses or their infrastructures differs from that obtained by other fabrication techniques using a similar restorative material and whether it depends on the type of restorative material. An electronic search of English-language literature published between January 1, 2000, and June 30, 2016, was conducted of the Medline/PubMed database. Of the 55 included comparative studies, 28 compared CAD-CAM technology with conventional fabrication techniques, 12 contrasted CAD-CAM technology and copy milling, 4 compared CAD-CAM milling with direct metal laser sintering (DMLS), and 22 investigated the performance of a CAD-CAM system regarding marginal adaptation in restorations/infrastructures produced with different restorative materials. Most of the CAD-CAM restorations/infrastructures were within the clinically acceptable marginal discrepancy (MD) range. The performance of a CAD-CAM system relative to marginal adaptation is influenced by the restorative material. Compared with CAD-CAM, most of the heat-pressed lithium disilicate crowns displayed equal or smaller MD values. Slip-casting crowns exhibited similar or better marginal accuracy than those fabricated with CAD-CAM. Cobalt-chromium and titanium implant infrastructures produced using a CAD-CAM system elicited smaller MD values than zirconia. The majority of cobalt-chromium restorations/infrastructures produced by DMLS displayed better marginal accuracy than those fabricated with the casting technique. Compared with copy milling, the majority of zirconia restorations/infrastructures produced by CAD-CAM milling exhibited better marginal adaptation. No clear conclusions can be drawn about the superiority of CAD-CAM milling over the casting technique and DMLS regarding marginal adaptation. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Springback Simulation and Compensation for High Strength Parts Using JSTAMP
NASA Astrophysics Data System (ADS)
Shindo, Terumasa; Sugitomo, Nobuhiko; Ma, Ninshu
2011-08-01
The stamping parts made from high strength steel have a large springback which is difficult to control. With the development of simulation technology, the springback can be accurately predicted using advanced kinematic material models and CAE systems. In this paper, a stamping process for a pillar part made from several classes of high strength steel was simulated using a Yoshida-Uemori kinematic material model and the springback was well predicted. To obtain the desired part shape, CAD surfaces of the stamping tools were compensated by a CAE system JSTAMP. After applying the compensation 2 or 3 times, the dimension accuracy of the simulation for the part shape achieved was about 0.5 mm. The compensated CAD surfaces of the stamping tools were directly exported from JSTAMP to CAM for machining. The effectiveness of the compensation was verified by an experiment using the compensated tools.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, K.L.
This document has been developed to provide guidance in the interchange of electronic CAD data with Martin Marietta Energy Systems, Inc., Oak Ridge, Tennessee. It is not meant to be as comprehensive as the existing standards and specifications, but to provide a minimum set of practices that will enhance the success of the CAD data exchange. It is now a Department of Energy (DOE) Oak Ridge Field Office requirement that Architect-Engineering (A-E) firms prepare all new drawings using a Computer Aided Design (CAD) system that is compatible with the Facility Manager`s (FM) CAD system. For Oak Ridge facilities, the CADmore » system used for facility design by the FM, Martin Marietta Energy Systems, Inc., is Intregraph. The format for interchange of CAD data for Oak Ridge facilities will be the Intergraph MicroStation/IGDS format.« less
Performance testing of LiDAR exploitation software
NASA Astrophysics Data System (ADS)
Varela-González, M.; González-Jorge, H.; Riveiro, B.; Arias, P.
2013-04-01
Mobile LiDAR systems are being used widely in recent years for many applications in the field of geoscience. One of most important limitations of this technology is the large computational requirements involved in data processing. Several software solutions for data processing are available in the market, but users are often unknown about the methodologies to verify their performance accurately. In this work a methodology for LiDAR software performance testing is presented and six different suites are studied: QT Modeler, AutoCAD Civil 3D, Mars 7, Fledermaus, Carlson and TopoDOT (all of them in x64). Results depict as QTModeler, TopoDOT and AutoCAD Civil 3D allow the loading of large datasets, while Fledermaus, Mars7 and Carlson do not achieve these powerful performance. AutoCAD Civil 3D needs large loading time in comparison with the most powerful softwares such as QTModeler and TopoDOT. Carlson suite depicts the poorest results among all the softwares under study, where point clouds larger than 5 million points cannot be loaded and loading time is very large in comparison with the other suites even for the smaller datasets. AutoCAD Civil 3D, Carlson and TopoDOT show more threads than other softwares like QTModeler, Mars7 and Fledermaus.
An application protocol for CAD to CAD transfer of electronic information
NASA Technical Reports Server (NTRS)
Azu, Charles C., Jr.
1993-01-01
The exchange of Computer Aided Design (CAD) information between dissimilar CAD systems is a problem. This is especially true for transferring electronics CAD information such as multi-chip module (MCM), hybrid microcircuit assembly (HMA), and printed circuit board (PCB) designs. Currently, there exists several neutral data formats for transferring electronics CAD information. These include IGES, EDIF, and DXF formats. All these formats have limitations for use in exchanging electronic data. In an attempt to overcome these limitations, the Navy's MicroCIM program implemented a project to transfer hybrid microcircuit design information between dissimilar CAD systems. The IGES (Initial Graphics Exchange Specification) format is used since it is well established within the CAD industry. The goal of the project is to have a complete transfer of microelectronic CAD information, using IGES, without any data loss. An Application Protocol (AP) is being developed to specify how hybrid microcircuit CAD information will be represented by IGES entity constructs. The AP defines which IGES data items are appropriate for describing HMA geometry, connectivity, and processing as well as HMA material characteristics.
Eom, Han Young; Park, So-Young; Kim, Min Kyung; Suh, Joon Hyuk; Yeom, Hyesun; Min, Jung Won; Kim, Unyong; Lee, Jeongmi; Youm, Jeong-Rok; Han, Sang Beom
2010-06-25
Saikosaponins are triterpene saponins derived from the roots of Bupleurum falcatum L. (Umbelliferae), which has been traditionally used to treat fever, inflammation, liver diseases, and nephritis. It is difficult to analyze saikosaponins using HPLC-UV due to the lack of chromophores. Therefore, evaporative light scattering detection (ELSD) is used as a valuable alternative to UV detection. More recently, a charged aerosol detection (CAD) method has been developed to improve the sensitivity and reproducibility of ELSD. In this study, we compared CAD and ELSD methods in the simultaneous analysis of 10 saikosaponins, including saikosaponins-A, -B(1), -B(2), -B(3), -B(4), -C, -D, -G, -H and -I. A mixture of the 10 saikosaponins was injected into the Ascentis Express C18 column (100 mm x 4.6 mm, 2.7 microm) with gradient elution and detection with CAD and ELSD by splitting. We examined various factors that could affect the sensitivity of the detectors including various concentrations of additives, pH and flow rate of the mobile phase, purity of nitrogen gas and the CAD range. The sensitivity was determined based on the signal-to-noise ratio. The best sensitivity for CAD was achieved with 0.1 mM ammonium acetate at pH 4.0 in the mobile phase with a flow rate of 1.0 mL/min, and the CAD range at 100 pA, whereas that for ELSD was achieved with 0.01% acetic acid in the mobile phase with a flow rate at 0.8 mL/min. The purity of the nitrogen gas had only minor effects on the sensitivities of both detectors. Finally, the sensitivity for CAD was two to six times better than that of ELSD. Taken together, these results suggest that CAD provides a more sensitive analysis of the 10 saikosaponins than does ELSD. Copyright 2010 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Franken, Ken; And Others
A multidisciplinary research team was assembled to review existing computer-aided drafting (CAD) systems for the purpose of enabling staff in the Design Drafting Department at Linn Technical College (Missouri) to select the best system out of the many CAD systems in existence. During the initial stage of the evaluation project, researchers…
Stypulkowska, Karolina; Fijalek, Zbigniew; Sarna, Katarzyna
2010-01-01
A new, simple and repeatable liquid chromatography method with charged aerosol detection (LC-CAD) for the determination of gentamicin sulphate composition and related substances has been developed. Gentamicin lacks of chromophores, therefore its determination is quite problematic. Using a universal CAD enables to achieve good separation without sample derivatization. Mass spectrometry was employed to confirm the LC-CAD peak profile. The proposed method was validated and applied for the determination of gentamicin sulphate composition and related substances in pharmaceutical preparations. PMID:21212825
Tani, Shigemasa; Nagao, Ken; Kawauchi, Kenji; Yagi, Tsukasa; Atsumi, Wataru; Matsuo, Rei; Hirayama, Atsushi
2017-10-01
We investigated the relationship between the eicosapentaenoic acid (EPA)/arachidonic acid (AA) ratio and non-high-density lipoprotein cholesterol (non-HDL-C) level, a major residual risk of coronary artery disease (CAD), in statin-treated CAD patients following EPA therapy. We conducted a 6-month, prospective, randomized clinical trial to investigate the effect of the additional administration of EPA on the EPA/AA ratio and the serum non-HDL-C level in stable CAD patients receiving statin treatment. We assigned CAD patients already receiving statin therapy to an EPA group (1800 mg/day; n = 50) or a control group (n = 50). A significant reduction in the serum non-HDL-C level was observed in the EPA group, compared with the control group (-9.7 vs. -1.2%, p = 0.01). A multiple-regression analysis with adjustments for coronary risk factors revealed that achieved EPA/AA ratio was more reliable as an independent and significant predictor of a reduction in the non-HDL-C level at a 6-month follow-up examination (β = -0.324, p = 0.033) than the absolute change in the EPA/AA ratio. Interestingly, significant negative correlations were found between the baseline levels and the absolute change values of both non-HDL-C and triglyceride-rich lipoproteins, both markers of residual risk of CAD, indicating that patients with a higher baseline residual risk achieved a greater reduction. The present results suggest that the achieved EPA/AA ratio, but not the absolute change in EPA/AA ratio, following EPA therapy might be a useful marker for the risk stratification of CAD among statin-treated patients with a high non-HDL-C level. UMIN ( http://www.umin.ac.jp/ ) Study ID: UMIN000010452.
Spatial data software integration - Merging CAD/CAM/mapping with GIS and image processing
NASA Technical Reports Server (NTRS)
Logan, Thomas L.; Bryant, Nevin A.
1987-01-01
The integration of CAD/CAM/mapping with image processing using geographic information systems (GISs) as the interface is examined. Particular emphasis is given to the development of software interfaces between JPL's Video Image Communication and Retrieval (VICAR)/Imaged Based Information System (IBIS) raster-based GIS and the CAD/CAM/mapping system. The design and functions of the VICAR and IBIS are described. Vector data capture and editing are studied. Various software programs for interfacing between the VICAR/IBIS and CAD/CAM/mapping are presented and analyzed.
Computer-aided diagnosis: A survey with bibliometric analysis.
Takahashi, Ryohei; Kajikawa, Yuya
2017-05-01
Computer-aided diagnosis (CAD) has been a promising area of research over the last two decades. However, CAD is a very complicated subject because it involves a number of medicine and engineering-related fields. To develop a research overview of CAD, we conducted a literature survey with bibliometric analysis, which we report here. Our study determined that CAD research has been classified and categorized according to disease type and imaging modality. This classification began with the CAD of mammograms and eventually progressed to that of brain disease. Furthermore, based on our results, we discuss future directions and opportunities for CAD research. First, in contrast to the typical hypothetical approach, the data-driven approach has shown promise. Second, the normalization of the test datasets and an evaluation method is necessary when adopting an algorithm and a system. Third, we discuss opportunities for the co-evolution of CAD research and imaging instruments-for example, the CAD of bones and pancreatic cancer. Fourth, the potential of synergy with CAD and clinical decision support systems is also discussed. Copyright © 2017 Elsevier B.V. All rights reserved.
Al-Masni, Mohammed A; Al-Antari, Mugahed A; Park, Jeong-Min; Gi, Geon; Kim, Tae-Yeon; Rivera, Patricio; Valarezo, Edwin; Choi, Mun-Taek; Han, Seung-Moo; Kim, Tae-Seong
2018-04-01
Automatic detection and classification of the masses in mammograms are still a big challenge and play a crucial role to assist radiologists for accurate diagnosis. In this paper, we propose a novel Computer-Aided Diagnosis (CAD) system based on one of the regional deep learning techniques, a ROI-based Convolutional Neural Network (CNN) which is called You Only Look Once (YOLO). Although most previous studies only deal with classification of masses, our proposed YOLO-based CAD system can handle detection and classification simultaneously in one framework. The proposed CAD system contains four main stages: preprocessing of mammograms, feature extraction utilizing deep convolutional networks, mass detection with confidence, and finally mass classification using Fully Connected Neural Networks (FC-NNs). In this study, we utilized original 600 mammograms from Digital Database for Screening Mammography (DDSM) and their augmented mammograms of 2,400 with the information of the masses and their types in training and testing our CAD. The trained YOLO-based CAD system detects the masses and then classifies their types into benign or malignant. Our results with five-fold cross validation tests show that the proposed CAD system detects the mass location with an overall accuracy of 99.7%. The system also distinguishes between benign and malignant lesions with an overall accuracy of 97%. Our proposed system even works on some challenging breast cancer cases where the masses exist over the pectoral muscles or dense regions. Copyright © 2018 Elsevier B.V. All rights reserved.
Infantino, M; Meacci, F; Grossi, V; Manfredi, M; Benucci, M; Merone, M; Soda, P
2017-02-01
According to the recent recommendations of the American College of Rheumatology, ANA Task Force, IIF technique should be considered the gold standard in antinuclear antibodies (ANAs) testing. To overcome the lack of standardization, biomedical industries have developed several computer-aided diagnosis (CAD) systems. Two hundred and sixty-one consecutive samples with suspected autoimmune diseases were tested for ANA by means of IIF on routinely HEp-2 assay kit (Euroimmun AG). Assignment of result was made if consensus for positive/negative was reached by at least 2 out of 3 expert physicians. ANA-IIF was also carried out using 3 CAD systems: Zenit G-Sight (n = 84), Helios (n = 85) and NOVA View (n = 92); human evaluation was repeated on the same substrate of each CAD system (Immco, Aesku and Inova HEp-2 cells, respectively). To anonymize the results, we randomly named these three systems as A, B and C. We ran a statistical analysis computing several measures of agreement between the ratings, and we also improved the evaluation by using the Wilcoxon's test for nonparametric data. Agreement between the human readings on routinely HEp-2 assay kit and human readings on CAD HEp-2 assay was substantial for A (k = 0.82) and B (k = 0.72), and almost perfect for C (k = 0.89). Such readings were statistically different only in case A. Comparing experts' readings with the readings of CAD systems, when the samples were prepared using CAD HEp-2 assay kits, we found almost perfect agreement for B and C (k = 0.86; k = 0.82) and substantial agreement for A (k = 0.73). Again, human and CAD readings were statistically different only in A. When we compared the readings of medical experts on routinely HEp-2 assay kit with the output of the CAD systems that worked using their own slides, we found substantial agreement for all the systems (A: k = 0.62; B: k = 0.65; C: k = 0.71). Such readings were not statistically different. The change of the assay kit and/or the introduction of a CAD system affect the laboratory reporting, with an evident impact on the autoimmune laboratory workflow. The CAD systems may represent one of the most important novel elements of harmonization in the autoimmunity field, reducing intra- and inter-laboratory variability in a new vision of the diagnostic autoimmune platform.
Wavelet method for CT colonography computer-aided polyp detection.
Li, Jiang; Van Uitert, Robert; Yao, Jianhua; Petrick, Nicholas; Franaszek, Marek; Huang, Adam; Summers, Ronald M
2008-08-01
Computed tomographic colonography (CTC) computer aided detection (CAD) is a new method to detect colon polyps. Colonic polyps are abnormal growths that may become cancerous. Detection and removal of colonic polyps, particularly larger ones, has been shown to reduce the incidence of colorectal cancer. While high sensitivities and low false positive rates are consistently achieved for the detection of polyps sized 1 cm or larger, lower sensitivities and higher false positive rates occur when the goal of CAD is to identify "medium"-sized polyps, 6-9 mm in diameter. Such medium-sized polyps may be important for clinical patient management. We have developed a wavelet-based postprocessor to reduce false positives for this polyp size range. We applied the wavelet-based postprocessor to CTC CAD findings from 44 patients in whom 45 polyps with sizes of 6-9 mm were found at segmentally unblinded optical colonoscopy and visible on retrospective review of the CT colonography images. Prior to the application of the wavelet-based postprocessor, the CTC CAD system detected 33 of the polyps (sensitivity 73.33%) with 12.4 false positives per patient, a sensitivity comparable to that of expert radiologists. Fourfold cross validation with 5000 bootstraps showed that the wavelet-based postprocessor could reduce the false positives by 56.61% (p <0.001), to 5.38 per patient (95% confidence interval [4.41, 6.34]), without significant sensitivity degradation (32/45, 71.11%, 95% confidence interval [66.39%, 75.74%], p=0.1713). We conclude that this wavelet-based postprocessor can substantially reduce the false positive rate of our CTC CAD for this important polyp size range.
21 CFR 872.3661 - Optical Impression Systems for CAD/CAM.
Code of Federal Regulations, 2011 CFR
2011-04-01
... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3661 Optical Impression Systems for CAD... (CAD/CAM) is a device used to record the topographical characteristics of teeth, dental impressions, or stone models by analog or digital methods for use in the computer-assisted design and manufacturing of...
Automatic image database generation from CAD for 3D object recognition
NASA Astrophysics Data System (ADS)
Sardana, Harish K.; Daemi, Mohammad F.; Ibrahim, Mohammad K.
1993-06-01
The development and evaluation of Multiple-View 3-D object recognition systems is based on a large set of model images. Due to the various advantages of using CAD, it is becoming more and more practical to use existing CAD data in computer vision systems. Current PC- level CAD systems are capable of providing physical image modelling and rendering involving positional variations in cameras, light sources etc. We have formulated a modular scheme for automatic generation of various aspects (views) of the objects in a model based 3-D object recognition system. These views are generated at desired orientations on the unit Gaussian sphere. With a suitable network file sharing system (NFS), the images can directly be stored on a database located on a file server. This paper presents the image modelling solutions using CAD in relation to multiple-view approach. Our modular scheme for data conversion and automatic image database storage for such a system is discussed. We have used this approach in 3-D polyhedron recognition. An overview of the results, advantages and limitations of using CAD data and conclusions using such as scheme are also presented.
Next Generation CAD/CAM/CAE Systems
NASA Technical Reports Server (NTRS)
Noor, Ahmed K. (Compiler); Malone, John B. (Compiler)
1997-01-01
This document contains presentations from the joint UVA/NASA Workshop on Next Generation CAD/CAM/CAE Systems held at NASA Langley Research Center in Hampton, Virginia on March 18-19, 1997. The presentations focused on current capabilities and future directions of CAD/CAM/CAE systems, aerospace industry projects, and university activities related to simulation-based design. Workshop attendees represented NASA, commercial software developers, the aerospace industry, government labs, and academia. The workshop objectives were to assess the potential of emerging CAD/CAM/CAE technology for use in intelligent simulation-based design and to provide guidelines for focused future research leading to effective use of CAE systems for simulating the entire life cycle of aerospace systems.
Foundation and methodologies in computer-aided diagnosis systems for breast cancer detection.
Jalalian, Afsaneh; Mashohor, Syamsiah; Mahmud, Rozi; Karasfi, Babak; Saripan, M Iqbal B; Ramli, Abdul Rahman B
2017-01-01
Breast cancer is the most prevalent cancer that affects women all over the world. Early detection and treatment of breast cancer could decline the mortality rate. Some issues such as technical reasons, which related to imaging quality and human error, increase misdiagnosis of breast cancer by radiologists. Computer-aided detection systems (CADs) are developed to overcome these restrictions and have been studied in many imaging modalities for breast cancer detection in recent years. The CAD systems improve radiologists' performance in finding and discriminating between the normal and abnormal tissues. These procedures are performed only as a double reader but the absolute decisions are still made by the radiologist. In this study, the recent CAD systems for breast cancer detection on different modalities such as mammography, ultrasound, MRI, and biopsy histopathological images are introduced. The foundation of CAD systems generally consist of four stages: Pre-processing, Segmentation, Feature extraction, and Classification. The approaches which applied to design different stages of CAD system are summarised. Advantages and disadvantages of different segmentation, feature extraction and classification techniques are listed. In addition, the impact of imbalanced datasets in classification outcomes and appropriate methods to solve these issues are discussed. As well as, performance evaluation metrics for various stages of breast cancer detection CAD systems are reviewed.
Foundation and methodologies in computer-aided diagnosis systems for breast cancer detection
Jalalian, Afsaneh; Mashohor, Syamsiah; Mahmud, Rozi; Karasfi, Babak; Saripan, M. Iqbal B.; Ramli, Abdul Rahman B.
2017-01-01
Breast cancer is the most prevalent cancer that affects women all over the world. Early detection and treatment of breast cancer could decline the mortality rate. Some issues such as technical reasons, which related to imaging quality and human error, increase misdiagnosis of breast cancer by radiologists. Computer-aided detection systems (CADs) are developed to overcome these restrictions and have been studied in many imaging modalities for breast cancer detection in recent years. The CAD systems improve radiologists' performance in finding and discriminating between the normal and abnormal tissues. These procedures are performed only as a double reader but the absolute decisions are still made by the radiologist. In this study, the recent CAD systems for breast cancer detection on different modalities such as mammography, ultrasound, MRI, and biopsy histopathological images are introduced. The foundation of CAD systems generally consist of four stages: Pre-processing, Segmentation, Feature extraction, and Classification. The approaches which applied to design different stages of CAD system are summarised. Advantages and disadvantages of different segmentation, feature extraction and classification techniques are listed. In addition, the impact of imbalanced datasets in classification outcomes and appropriate methods to solve these issues are discussed. As well as, performance evaluation metrics for various stages of breast cancer detection CAD systems are reviewed. PMID:28435432
21 CFR 872.3661 - Optical Impression Systems for CAD/CAM.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Optical Impression Systems for CAD/CAM. 872.3661 Section 872.3661 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Design and Manufacturing (CAD/CAM) of Dental Restorations; Guidance for Industry and FDA.” For the...
The marginal fit of E.max Press and E.max CAD lithium disilicate restorations: A critical review.
Mounajjed, Radek; M Layton, Danielle; Azar, Basel
2016-12-01
This critical review aimed to assess the vertical marginal gap that was present when E.max lithium disilicate-based restoration (Press and CAD) are fabricated in-vitro. Published articles reporting vertical marginal gap measurements of in-vitro restorations that had been fabricated from E.Max lithium disilicate were sought with an electronic search of MEDLINE (PubMed) and hand search of selected dental journals. The outcomes were reviewed qualitatively. The majority of studies that compared the marginal fit of E.max press and E.max CAD restorations, found that the E.max lithium disilicate restorations fabricated with the press technique had significantly smaller marginal gaps than those fabricated with CAD technique. This research indicates that E.max lithium disilicate restorations fabricated with the press technique have measurably smaller marginal gaps when compared with those fabricated with CAD techniques within in-vitro environments. The marginal gaps achieved by the restorations across all groups were within a clinically acceptable range.
Chen, Lei; Auh, Chung-Kyoon; Dowling, Paul; Bell, Jeremey; Chen, Fang; Hopkins, Andrew; Dixon, Richard A; Wang, Zeng-Yu
2003-11-01
Lignification of cell walls during plant development has been identified as the major factor limiting forage digestibility and concomitantly animal productivity. cDNA sequences encoding a key lignin biosynthetic enzyme, cinnamyl alcohol dehydrogenase (CAD), were cloned from the widely grown monocotyledonous forage species tall fescue (Festuca arundinacea Schreb.). Recombinant tall fescue CAD expressed in E. coli exhibited the highest V(max)/K(m) values when coniferaldehyde and sinapaldehyde were used as substrates. Transgenic tall fescue plants carrying either sense or antisense CAD gene constructs were obtained by microprojectile bombardment of single genotype-derived embryogenic suspension cells. Severely reduced levels of mRNA transcripts and significantly reduced CAD enzymatic activities were found in two transgenic plants carrying sense and antisense CAD transgenes, respectively. These CAD down-regulated transgenic lines had significantly decreased lignin content and altered ratios of syringyl (S) to guaiacyl (G), G to p-hydroxyphenyl (H) and S to H units. No significant changes in cellulose, hemicellulose, neutral sugar composition, p-coumaric acid and ferulic acid levels were observed in the transgenic plants. Increases of in vitro dry matter digestibility of 7.2-9.5% were achieved in the CAD down-regulated lines, thus providing a novel germplasm to be used for the development of grass cultivars with improved forage quality.
Education and Training Packages for CAD/CAM.
ERIC Educational Resources Information Center
Wright, I. C.
1986-01-01
Discusses educational efforts in the fields of Computer Assisted Design and Manufacturing (CAD/CAM). Describes two educational training initiatives underway in the United Kingdom, one of which is a resource materials package for teachers of CAD/CAM at the undergraduate level, and the other a training course for managers of CAD/CAM systems. (TW)
Eadie, Leila H; Taylor, Paul; Gibson, Adam P
2012-04-01
Computer-assisted diagnosis (CAD) describes a diverse, heterogeneous range of applications rather than a single entity. The aims and functions of CAD systems vary considerably and comparing studies and systems is challenging due to methodological and design differences. In addition, poor study quality and reporting can reduce the value of some publications. Meta-analyses of CAD are therefore difficult and may not provide reliable conclusions. Aiming to determine the major sources of heterogeneity and thereby what CAD researchers could change to allow this sort of assessment, this study reviews a sample of 147 papers concerning CAD used with imaging for cancer diagnosis. It discusses sources of variability, including the goal of the CAD system, learning methodology, study population, design, outcome measures, inclusion of radiologists, and study quality. Based upon this evidence, recommendations are made to help researchers optimize the quality and comparability of their trial design and reporting. Copyright © 2011 Elsevier Inc. All rights reserved.
Computed-aided diagnosis (CAD) in the detection of breast cancer.
Dromain, C; Boyer, B; Ferré, R; Canale, S; Delaloge, S; Balleyguier, C
2013-03-01
Computer-aided detection (CAD) systems have been developed for interpretation to improve mammographic detection of breast cancer at screening by reducing the number of false-negative interpretation that can be caused by subtle findings, radiologist distraction and complex architecture. They use a digitized mammographic image that can be obtained from both screen-film mammography and full field digital mammography. Its performance in breast cancer detection is dependent on the performance of the CAD itself, the population to which it is applied and the radiologists who use it. There is a clear benefit to the use of CAD in less experienced radiologist and in detecting breast carcinomas presenting as microcalcifications. This review gives a detailed description CAD systems used in mammography and their performance in assistance of reading in screening mammography and as an alternative to double reading. Other CAD systems developed for MRI and ultrasound are also presented and discussed. Copyright © 2012. Published by Elsevier Ireland Ltd.
The design and integration of retinal CAD-SR to diabetes patient ePR system
NASA Astrophysics Data System (ADS)
Wu, Huiqun; Wei, Yufang; Liu, Brent J.; Shang, Yujuan; Shi, Lili; Jiang, Kui; Dong, Jiancheng
2017-03-01
Diabetic retinopathy (DR) is one of the serious complications of diabetes that could lead to blindness. Digital fundus camera is often used to detect retinal changes but the diagnosis relies too much on ophthalmologist's experience. Based on our previously developed algorithms for quantifying retinal vessels and lesions, we developed a computer aided detection-structured report (CAD-SR) template and implemented it into picture archiving and communication system (PACS). Furthermore, we mapped our CAD-SR into HL7 CDA to integrate CAD findings into diabetes patient electronic patient record (ePR) system. Such integration could provide more quantitative features from fundus image into ePR system, which is valuable for further data mining researches.
Marginal and internal fits of fixed dental prostheses zirconia retainers.
Beuer, Florian; Aggstaller, Hans; Edelhoff, Daniel; Gernet, Wolfgang; Sorensen, John
2009-01-01
CAM (computer-aided manufacturing) and CAD (computer-aided design)/CAM systems facilitate the use of zirconia substructure materials for all-ceramic fixed partial dentures. This in vitro study compared the precision of fit of frameworks milled from semi-sintered zirconia blocks that were designed and machined with two CAD/CAM and one CAM system. Three-unit posterior fixed dental prostheses (FDP) (n=10) were fabricated for standardized dies by: a milling center CAD/CAM system (Etkon), a laboratory CAD/CAM system (Cerec InLab), and a laboratory CAM system (Cercon). After adaptation by a dental technician, the FDP were cemented on definitive dies, embedded and sectioned. The marginal and internal fits were measured under an optical microscope at 50x magnification. A one-way analysis of variance (ANOVA) was used to compare data (alpha=0.05). The mean (S.D.) for the marginal fit and internal fit adaptation were: 29.1 microm (14.0) and 62.7 microm (18.9) for the milling center system, 56.6 microm (19.6) and 73.5 microm (20.6) for the laboratory CAD/CAM system, and 81.4 microm (20.3) and 119.2 microm (37.5) for the laboratory CAM system. One-way ANOVA showed significant differences between systems for marginal fit (P<0.001) and internal fit (P<0.001). All systems showed marginal gaps below 120 microm and were therefore considered clinically acceptable. The CAD/CAM systems were more precise than the CAM system.
An automated distinction of DICOM images for lung cancer CAD system
NASA Astrophysics Data System (ADS)
Suzuki, H.; Saita, S.; Kubo, M.; Kawata, Y.; Niki, N.; Nishitani, H.; Ohmatsu, H.; Eguchi, K.; Kaneko, M.; Moriyama, N.
2009-02-01
Automated distinction of medical images is an important preprocessing in Computer-Aided Diagnosis (CAD) systems. The CAD systems have been developed using medical image sets with specific scan conditions and body parts. However, varied examinations are performed in medical sites. The specification of the examination is contained into DICOM textual meta information. Most DICOM textual meta information can be considered reliable, however the body part information cannot always be considered reliable. In this paper, we describe an automated distinction of DICOM images as a preprocessing for lung cancer CAD system. Our approach uses DICOM textual meta information and low cost image processing. Firstly, the textual meta information such as scan conditions of DICOM image is distinguished. Secondly, the DICOM image is set to distinguish the body parts which are identified by image processing. The identification of body parts is based on anatomical structure which is represented by features of three regions, body tissue, bone, and air. The method is effective to the practical use of lung cancer CAD system in medical sites.
Ribeiro, Isabella Lima Arrais; Campos, Fernanda; Sousa, Rafael Santiago; Alves, Maria Luiza Lima; Rodrigues, Dalton Matos; Souza, Rodrigo Othavio Assuncão; Bottino, Marco Antonio
2015-01-01
Discrepancies at the abutment/crown interface can affect the longevity of zirconia restorations. The aim was to evaluate the marginal and internal discrepancies (MD and ID) of zirconia copings manufactured by two milling systems with different finish lines. Three aluminum-master-dies (h = 5.5 mm; Ψ =7.5 mm; 6), with different finish lines (large chamfer [LC]; tilted chamfer [TC]; rounded shoulder [RS]) were fabricated. Twenty impressions were made from each master die and poured. Sixty zirconia copings were manufactured and divided according to the factors "finish line" and "milling system" (n = 10): CAD LC = Computer-aided design/computer-aided manufacturing (CAD/CAM) + LC; CAD TC = CAD/CAM + TC; CAD RS = CAD/CAM + RS; MAD LC = manually aided design/manually aided manufacturing (MAD/MAM) + LC; MAD TC = MAD/MAM + TC; and MAD RS = MAD/MAM + RS. For MD analysis, each coping was fixed, and the distance between the external edges of the coping and the edge of the cervical preparation was measured (50 points). Using the same copings, the ID of each coping was evaluated, by the replica technique, at 12 points equally distributed among the regions (n = 10): Ray (R), axial (A), and occlusal (Occl). The measurements were performed by optical microscopy (Χ250). The data (μm) were subjected to parametric and non-parametric statistical analyses. For the MAD/MAM system, the "finish line" (P = 0.0001) affected significantly the MD median values (μm): LC = 251.80 a , RS = 68.40 a and TC = 8.10 b (Dunn's test). For the CAD/CAM system, the median MD values (μm) were not affected by the factor "finish line" (P = 0.4037): LC = 0.82 a , RS = 0.52 a , and TC = 0.89 a . For the ID, it was observed interaction between the finish line types and the region (P = 0.0001) and between region and milling system (P = 0.0031) (RM-ANOVA). The CAD/CAM system presented lower MD values, regardless the finish line. However, the MAD/MAM system showed ID values smaller than those of CAD/CAM.
The Use of a Parametric Feature Based CAD System to Teach Introductory Engineering Graphics.
ERIC Educational Resources Information Center
Howell, Steven K.
1995-01-01
Describes the use of a parametric-feature-based computer-aided design (CAD) System, AutoCAD Designer, in teaching concepts of three dimensional geometrical modeling and design. Allows engineering graphics to go beyond the role of documentation and communication and allows an engineer to actually build a virtual prototype of a design idea and…
Ji, Min-Kyung; Park, Ji-Hee; Park, Sang-Won; Yun, Kwi-Dug; Oh, Gye-Jeong; Lim, Hyun-Pil
2015-08-01
This study was to evaluate the marginal fit of two CAD-CAM anatomic contour zirconia crown systems compared to lithium disilicate glass-ceramic crowns. Shoulder and deep chamfer margin were formed on each acrylic resin tooth model of a maxillary first premolar. Two CAD-CAM systems (Prettau®Zirconia and ZENOSTAR®ZR translucent) and lithium disilicate glass ceramic (IPS e.max®press) crowns were made (n=16). Each crown was bonded to stone dies with resin cement (Rely X Unicem). Marginal gap and absolute marginal discrepancy of crowns were measured using a light microscope equipped with a digital camera (Leica DFC295) magnified by a factor of 100. Two-way analysis of variance (ANOVA) and post-hoc Tukey's HSD test were conducted to analyze the significance of crown marginal fit regarding the finish line configuration and the fabrication system. The mean marginal gap of lithium disilicate glass ceramic crowns (IPS e.max®press) was significantly lower than that of the CAD-CAM anatomic contour zirconia crown system (Prettau®Zirconia) (P<.05). Both fabrication systems and finish line configurations significantly influenced the absolute marginal discrepancy (P<.05). The lithium disilicate glass ceramic crown (IPS e.max®press) had significantly smaller marginal gap than the CAD-CAM anatomic contour zirconia crown system (Prettau®Zirconia). In terms of absolute marginal discrepancy, the CAD-CAM anatomic contour zirconia crown system (ZENOSTAR®ZR translucent) had under-extended margin, whereas the CAD-CAM anatomic contour zirconia crown system (Prettau®Zirconia) and lithium disilicate glass ceramic crowns (IPS e.max®press) had overextended margins.
Wu, Minghua; Pedroza, Mesias; Lafyatis, Robert; George, Anuh-Teresa; Mayes, Maureen D.; Assassi, Shervin; Tan, Filemon K.; Brenner, Michael B.; Agarwal, Sandeep K.
2014-01-01
Objective Systemic sclerosis (SSc) is a chronic autoimmune disease clinically manifesting as progressive fibrosis of the skin and internal organs. Recent microarray studies demonstrated that cadherin 11 (Cad-11) expression is increased in the affected skin of patients with SSc. The purpose of this study was to examine our hypothesis that Cad-11 is a mediator of dermal fibrosis. Methods Biopsy samples of skin from SSc patients and healthy control subjects were used for real-time quantitative polymerase chain reaction analysis to assess Cad-11 expression and for immunohistochemistry to determine the expression pattern of Cad-11. To determine whether Cad-11 is a mediator of dermal fibrosis, Cad-11–deficient mice and anti–Cad-11 monoclonal antibodies (mAb) were used in the bleomycin-induced dermal fibrosis model. In vitro studies with dermal fibroblasts and bone marrow–derived macrophages were used to determine the mechanisms by which Cad-11 contributes to the development of tissue fibrosis. Results Levels of messenger RNA for Cad-11 were increased in skin biopsy samples from patients with SSc and correlated with the modified Rodnan skin thickness scores. Cad-11 expression was localized to dermal fibroblasts and macrophages in SSc skin. Cad-11–knockout mice injected with bleomycin had markedly attenuated dermal fibrosis, as quantified by measurements of skin thickness, collagen levels, myofibroblast accumulation, and profibrotic gene expression, in lesional skin as compared to the skin of wild-type mice. In addition, anti–Cad-11 mAb decreased fibrosis at various time points in the bleomycin-induced dermal fibrosis model. In vitro studies demonstrated that Cad-11 regulated the production of transforming growth factor β (TGFβ) by macrophages and the migration of fibroblasts. Conclusion These data demonstrate that Cad-11 is a mediator of dermal fibrosis and TGFβ production and suggest that Cad-11 may be a therapeutic target in SSc. PMID:24757152
Hochman, J; Urowitz, M B; Ibañez, D; Gladman, D D
2009-04-01
We sought to determine the impact of hormone replacement therapy (HRT) on the occurrence of coronary artery disease (CAD) in women with systemic lupus erythematosus (SLE). Women in the University of Toronto lupus database who had taken HRT with no history of CAD were compared with all post-menopausal female patients with no history of HRT or CAD. Chi-squared and t-tests were used to compare the risk factors of CAD and Kaplan-Meier curve, log rank test and proportional hazard model with time-dependent covariates were used to compare the time from entry into the clinic to occurrence of CAD. A total of 114 HRT-user patients with no history of CAD were compared with 227 post-menopausal non-HRT user SLE controls. The groups were similar with respect to lupus anticoagulant, antiphospholipid antibody, cumulative steroid dose and classic cardiac risk factors. A similar percentage of patients developed CAD in the control (13.7%) and HRT (11.4%) groups. There was no difference in the time to development of CAD. In the multivariate analysis, HRT was not a risk factor for CAD. Only age (P = 0.0001, HR = 1.11, 95% CI = 1.05, 1.17) and SLEDAI-2K (P = 0.0001, HR = 1.10, 95% CI = 1.05, 1.16) were significantly associated with the risk of CAD. In this small group of patients with SLE, HRT alone did not appear to predispose to CAD.
Cam Design Projects in an Advanced CAD Course for Mechanical Engineers
ERIC Educational Resources Information Center
Ault, H. K.
2009-01-01
The objective of this paper is to present applications of solid modeling aimed at modeling of complex geometries such as splines and blended surfaces in advanced CAD courses. These projects, in CAD-based Mechanical Engineering courses, are focused on the use of the CAD system to solve design problems for applications in machine design, namely the…
A step-by-step introduction to rule-based design of synthetic genetic constructs using GenoCAD.
Wilson, Mandy L; Hertzberg, Russell; Adam, Laura; Peccoud, Jean
2011-01-01
GenoCAD is an open source web-based system that provides a streamlined, rule-driven process for designing genetic sequences. GenoCAD provides a graphical interface that allows users to design sequences consistent with formalized design strategies specific to a domain, organization, or project. Design strategies include limited sets of user-defined parts and rules indicating how these parts are to be combined in genetic constructs. In addition to reducing design time to minutes, GenoCAD improves the quality and reliability of the finished sequence by ensuring that the designs follow established rules of sequence construction. GenoCAD.org is a publicly available instance of GenoCAD that can be found at www.genocad.org. The source code and latest build are available from SourceForge to allow advanced users to install and customize GenoCAD for their unique needs. This chapter focuses primarily on how the GenoCAD tools can be used to organize genetic parts into customized personal libraries, then how these libraries can be used to design sequences. In addition, GenoCAD's parts management system and search capabilities are described in detail. Instructions are provided for installing a local instance of GenoCAD on a server. Some of the future enhancements of this rapidly evolving suite of applications are briefly described. Copyright © 2011 Elsevier Inc. All rights reserved.
Lanktree, Matthew B; Hegele, Robert A
2009-02-26
Despite the recent success of genome-wide association studies (GWASs) in identifying loci consistently associated with coronary artery disease (CAD), a large proportion of the genetic components of CAD and its metabolic risk factors, including plasma lipids, type 2 diabetes and body mass index, remain unattributed. Gene-gene and gene-environment interactions might produce a meaningful improvement in quantification of the genetic determinants of CAD. Testing for gene-gene and gene-environment interactions is thus a new frontier for large-scale GWASs of CAD. There are several anecdotal examples of monogenic susceptibility to CAD in which the phenotype was worsened by an adverse environment. In addition, small-scale candidate gene association studies with functional hypotheses have identified gene-environment interactions. For future evaluation of gene-gene and gene-environment interactions to achieve the same success as the single gene associations reported in recent GWASs, it will be important to pre-specify agreed standards of study design and statistical power, environmental exposure measurement, phenomic characterization and analytical strategies. Here we discuss these issues, particularly in relation to the investigation and potential clinical utility of gene-gene and gene-environment interactions in CAD.
Integrated multidisciplinary CAD/CAE environment for micro-electro-mechanical systems (MEMS)
NASA Astrophysics Data System (ADS)
Przekwas, Andrzej J.
1999-03-01
Computational design of MEMS involves several strongly coupled physical disciplines, including fluid mechanics, heat transfer, stress/deformation dynamics, electronics, electro/magneto statics, calorics, biochemistry and others. CFDRC is developing a new generation multi-disciplinary CAD systems for MEMS using high-fidelity field solvers on unstructured, solution-adaptive grids for a full range of disciplines. The software system, ACE + MEMS, includes all essential CAD tools; geometry/grid generation for multi- discipline, multi-equation solvers, GUI, tightly coupled configurable 3D field solvers for FVM, FEM and BEM and a 3D visualization/animation tool. The flow/heat transfer/calorics/chemistry equations are solved with unstructured adaptive FVM solver, stress/deformation are computed with a FEM STRESS solver and a FAST BEM solver is used to solve linear heat transfer, electro/magnetostatics and elastostatics equations on adaptive polygonal surface grids. Tight multidisciplinary coupling and automatic interoperability between the tools was achieved by designing a comprehensive database structure and APIs for complete model definition. The virtual model definition is implemented in data transfer facility, a publicly available tool described in this paper. The paper presents overall description of the software architecture and MEMS design flow in ACE + MEMS. It describes current status, ongoing effort and future plans for the software. The paper also discusses new concepts of mixed-level and mixed- dimensionality capability in which 1D microfluidic networks are simulated concurrently with 3D high-fidelity models of discrete components.
Achieving the desired colour in discoloured teeth, using leucite-based CAD-CAM laminate systems.
Turgut, Sedanur; Bagis, Bora; Ayaz, Elif Aydogan
2014-01-01
To evaluate the cumulative effect of the abutment tooth and resin cement colour on the resultant optical properties of porcelain laminate veneers (PLVs) fabricated with leucite-based CAD/CAM blocks with different shades and thicknesses. A total of 224 ceramic specimens were prepared from the IPS Empress CAD with four different shades of HT-A1, LT-A1, MT-A1 and Bl-1. Resin composite discs were prepared with shade A3.5. For the cementation, 4 different shades of light-cure resin cements were chosen. L*, a*, and b* values, as well as the chroma (C) and hue (h) values of each cemented ceramic and the A1 shade table, were recorded. L*, Cab* and hab* values of the cemented ceramics were influenced by ceramic shade, ceramic thickness, cement shade, and interaction terms of the three variables. There were significant differences between the 1-mm-thick ceramic veneers that exhibited higher L* and lower Cab* values compared with veneers that were 0.5mm in thickness. Using the Tr shade cement resulted in lower L* and higher Cab* values for all thicknesses and ceramic shades, whereas the WO shade cement resulted in higher values. The selected colour of a laminate restoration is significantly affected by the ceramic shade, ceramic thickness and resin cement shade. Using the WO shade resin cement seems to be more effective in masking the discoloured abutment tooth. Clinicians should also select the translucency level of the ceramic block with the shade when a leucite-based CAD/CAM system is chosen to treat a discoloured tooth. Copyright © 2013 Elsevier Ltd. All rights reserved.
CAD-RADS - a new clinical decision support tool for coronary computed tomography angiography.
Foldyna, Borek; Szilveszter, Bálint; Scholtz, Jan-Erik; Banerji, Dahlia; Maurovich-Horvat, Pál; Hoffmann, Udo
2018-04-01
Coronary computed tomography angiography (CTA) has been established as an accurate method to non-invasively assess coronary artery disease (CAD). The proposed 'Coronary Artery Disease Reporting and Data System' (CAD-RADS) may enable standardised reporting of the broad spectrum of coronary CTA findings related to the presence, extent and composition of coronary atherosclerosis. The CAD-RADS classification is a comprehensive tool for summarising findings on a per-patient-basis dependent on the highest-grade coronary artery lesion, ranging from CAD-RADS 0 (absence of CAD) to CAD-RADS 5 (total occlusion of a coronary artery). In addition, it provides suggestions for clinical management for each classification, including further testing and therapeutic options. Despite some limitations, CAD-RADS may facilitate improved communication between imagers and patient caregivers. As such, CAD-RADS may enable a more efficient use of coronary CTA leading to more accurate utilisation of invasive coronary angiograms. Furthermore, widespread use of CAD-RADS may facilitate registry-based research of diagnostic and prognostic aspects of CTA. • CAD-RADS is a tool for standardising coronary CTA reports. • CAD-RADS includes clinical treatment recommendations based on CTA findings. • CAD-RADS has the potential to reduce variability of CTA reports.
Choi, Young Jun; Baek, Jung Hwan; Park, Hye Sun; Shim, Woo Hyun; Kim, Tae Yong; Shong, Young Kee; Lee, Jeong Hyun
2017-04-01
An initial clinical assessment is described of a new, commercially available, computer-aided diagnosis (CAD) system using artificial intelligence (AI) for thyroid ultrasound, and its performance is evaluated in the diagnosis of malignant thyroid nodules and categorization of nodule characteristics. Patients with thyroid nodules with decisive diagnosis, whether benign or malignant, were consecutively enrolled from November 2015 to February 2016. An experienced radiologist reviewed the ultrasound image characteristics of the thyroid nodules, while another radiologist assessed the same thyroid nodules using the CAD system, providing ultrasound characteristics and a diagnosis of whether nodules were benign or malignant. The diagnostic performance and agreement of US characteristics between the experienced radiologist and the CAD system were compared. In total, 102 thyroid nodules from 89 patients were included; 59 (57.8%) were benign and 43 (42.2%) were malignant. The CAD system showed a similar sensitivity as the experienced radiologist (90.7% vs. 88.4%, p > 0.99), but a lower specificity and a lower area under the receiver operating characteristic (AUROC) curve (specificity: 74.6% vs. 94.9%, p = 0.002; AUROC: 0.83 vs. 0.92, p = 0.021). Classifications of the ultrasound characteristics (composition, orientation, echogenicity, and spongiform) between radiologist and CAD system were in substantial agreement (κ = 0.659, 0.740, 0.733, and 0.658, respectively), while the margin showed a fair agreement (κ = 0.239). The sensitivity of the CAD system using AI for malignant thyroid nodules was as good as that of the experienced radiologist, while specificity and accuracy were lower than those of the experienced radiologist. The CAD system showed an acceptable agreement with the experienced radiologist for characterization of thyroid nodules.
Chen, Zhang-wei; Qian, Ju-ying; Jian, Ying; Ge, Lei; Liu, Xue-bo; Shu, Xian-hong; Ge, Junbo
2011-02-01
Aortic valve calcification (AVC) is common in the elderly and associated with increased cardiovascular mortality, while diabetes is one of the confirmed risk factors for coronary artery disease (CAD). In this study, we aimed to evaluate the prevalence and severity of CAD in type-2 diabetic patients with AVC. From June to December in 2007, a total of 325 consecutive patients with chest pain or chest distress were admitted for coronary angiography. The severity of CAD was evaluated by the Gensini score and the number of stenosed vessels. All patients underwent transthoracic echocardiography for detecting AVC. Compared with the patients without diabetes (n = 221), the type-2 diabetic patients (n = 104) had a similar prevalence of CAD (66.5% vs. 72.1%, P = 0.312). Further classified by the presence of AVC, patients with AVC had a higher prevalence of CAD, average Gensini score and the number of stenosed vessels, both in the group with and without diabetes. It was also demonstrated that the odds ratio (OR) of AVC for CAD in the diabetic patients was higher than in the non-diabetic ones (3.405 vs 2.515) after chi-square analysis (single-variable). However, at multivariable logistic regression analysis for CAD, the OR of AVC was 3.757 (P = 0.03) in diabetic group, while it did not achieve statistical significance in the non-diabetic group (OR = 2.130, P= 0.074). Type-2 diabetic patients with AVC had a higher prevalence of and more severe CAD.
IFEMS, an Interactive Finite Element Modeling System Using a CAD/CAM System
NASA Technical Reports Server (NTRS)
Mckellip, S.; Schuman, T.; Lauer, S.
1980-01-01
A method of coupling a CAD/CAM system with a general purpose finite element mesh generator is described. The three computer programs which make up the interactive finite element graphics system are discussed.
Luo, Jinghuan; Lu, Xueqin; Liu, Jianyong; Qian, Guangren; Lu, Yongsheng
2014-12-01
Biogas, generated from an expanded granular sludge bed (EGSB) reactor treating municipal solid waste (MSW) leachate, was recirculated for calcium removal from the leachate via a carbonation process with simultaneous biogas purification. Batch trials were performed to optimize the solution pH and imported biogas (CO2) for CaCO3 precipitation. With applicable pH of 10-11 obtained, continuous trials achieved final calcium concentrations of 181-375 mg/L (removal efficiencies≈92.8-96.5%) in the leachate and methane contents of 87.1-91.4% (purification efficiencies≈65.4-82.2%) in the biogas. Calcium-balance study indicates that 23-986 mg Ca/d was released from the bio-system under the carbonized condition where CaCO3 precipitating was moved outside the bioreactor, whereas 7918-9517 mg Ca/d was trapped into the system for the controlled one. These findings demonstrate that carbonation removal of calcium by biogas recirculation could be a promising alternative to pretreat calcium-rich MSW leachate and synergistically to improve methane content. Copyright © 2014 Elsevier Ltd. All rights reserved.
Version control system of CAD documents and PLC projects
NASA Astrophysics Data System (ADS)
Khudyakov, P. Yu; Kisel’nikov, A. Yu; Startcev, I. M.; Kovalev, A. A.
2018-05-01
The paper presents the process of developing a version control system for CAD documents and PLC projects. The software was tested and the optimal composition of the modules was selected. The introduction of the system has made it possible to increase the safety and stability of the process control systems, as well as to reduce the number of conflicts for versions of CAD files. The number of incidents at the enterprise related to the use of incorrect versions of PLC projects is reduced to 0.
Alqahtani, Fawaz
2017-01-01
The purpose of this study was to determine the effect of two extraoral computer-aided design (CAD) and computer-aided manufacturing (CAM) systems, in comparison with conventional techniques, on the marginal fit of monolithic CAD/CAM lithium disilicate ceramic crowns. This is an in vitro interventional study. The study was carried out at the Department of Prosthodontics, School of Dentistry, Prince Sattam Bin Abdul-Aziz University, Saudi Arabia, from December 2015 to April 2016. A marginal gap of 60 lithium disilicate crowns was evaluated by scanning electron microscopy. In total, 20 pressable lithium disilicate (IPS e.max Press [Ivoclar Vivadent]) ceramic crowns were fabricated using the conventional lost-wax technique as a control group. The experimental all-ceramic crowns were produced based on a scan stone model and milled using two extraoral CAD/CAM systems: the Cerec group was fabricated using the Cerec CAD/CAM system, and the Trios group was fabricated using Trios CAD and milled using Wieland Zenotec CAM. One-way analysis of variance (ANOVA) and the Scheffe post hoc test were used for statistical comparison of the groups (α=0.05). The mean (±standard deviation) of the marginal gap of each group was as follows: the Control group was 91.15 (±15.35) µm, the Cerec group was 111.07 (±6.33) µm, and the Trios group was 60.17 (±11.09) µm. One-way ANOVA and the Scheffe post hoc test showed a statistically significant difference in the marginal gap between all groups. It can be concluded from the current study that all-ceramic crowns, fabricated using the CAD/CAM system, show a marginal accuracy that is acceptable in clinical environments. The Trios CAD group displayed the smallest marginal gap.
Information fusion for diabetic retinopathy CAD in digital color fundus photographs.
Niemeijer, Meindert; Abramoff, Michael D; van Ginneken, Bram
2009-05-01
The purpose of computer-aided detection or diagnosis (CAD) technology has so far been to serve as a second reader. If, however, all relevant lesions in an image can be detected by CAD algorithms, use of CAD for automatic reading or prescreening may become feasible. This work addresses the question how to fuse information from multiple CAD algorithms, operating on multiple images that comprise an exam, to determine a likelihood that the exam is normal and would not require further inspection by human operators. We focus on retinal image screening for diabetic retinopathy, a common complication of diabetes. Current CAD systems are not designed to automatically evaluate complete exams consisting of multiple images for which several detection algorithm output sets are available. Information fusion will potentially play a crucial role in enabling the application of CAD technology to the automatic screening problem. Several different fusion methods are proposed and their effect on the performance of a complete comprehensive automatic diabetic retinopathy screening system is evaluated. Experiments show that the choice of fusion method can have a large impact on system performance. The complete system was evaluated on a set of 15,000 exams (60,000 images). The best performing fusion method obtained an area under the receiver operator characteristic curve of 0.881. This indicates that automated prescreening could be applied in diabetic retinopathy screening programs.
Komeda, Yoriaki; Handa, Hisashi; Watanabe, Tomohiro; Nomura, Takanobu; Kitahashi, Misaki; Sakurai, Toshiharu; Okamoto, Ayana; Minami, Tomohiro; Kono, Masashi; Arizumi, Tadaaki; Takenaka, Mamoru; Hagiwara, Satoru; Matsui, Shigenaga; Nishida, Naoshi; Kashida, Hiroshi; Kudo, Masatoshi
2017-01-01
Computer-aided diagnosis (CAD) is becoming a next-generation tool for the diagnosis of human disease. CAD for colon polyps has been suggested as a particularly useful tool for trainee colonoscopists, as the use of a CAD system avoids the complications associated with endoscopic resections. In addition to conventional CAD, a convolutional neural network (CNN) system utilizing artificial intelligence (AI) has been developing rapidly over the past 5 years. We attempted to generate a unique CNN-CAD system with an AI function that studied endoscopic images extracted from movies obtained with colonoscopes used in routine examinations. Here, we report our preliminary results of this novel CNN-CAD system for the diagnosis of colon polyps. A total of 1,200 images from cases of colonoscopy performed between January 2010 and December 2016 at Kindai University Hospital were used. These images were extracted from the video of actual endoscopic examinations. Additional video images from 10 cases of unlearned processes were retrospectively assessed in a pilot study. They were simply diagnosed as either an adenomatous or nonadenomatous polyp. The number of images used by AI to learn to distinguish adenomatous from nonadenomatous was 1,200:600. These images were extracted from the videos of actual endoscopic examinations. The size of each image was adjusted to 256 × 256 pixels. A 10-hold cross-validation was carried out. The accuracy of the 10-hold cross-validation is 0.751, where the accuracy is the ratio of the number of correct answers over the number of all the answers produced by the CNN. The decisions by the CNN were correct in 7 of 10 cases. A CNN-CAD system using routine colonoscopy might be useful for the rapid diagnosis of colorectal polyp classification. Further prospective studies in an in vivo setting are required to confirm the effectiveness of a CNN-CAD system in routine colonoscopy. © 2017 S. Karger AG, Basel.
CAD/CAM approach to improving industry productivity gathers momentum
NASA Technical Reports Server (NTRS)
Fulton, R. E.
1982-01-01
Recent results and planning for the NASA/industry Integrated Programs for Aerospace-Vehicle Design (IPAD) program for improving productivity with CAD/CAM methods are outlined. The industrial group work is being mainly done by Boeing, and progress has been made in defining the designer work environment, developing requirements and a preliminary design for a future CAD/CAM system, and developing CAD/CAM technology. The work environment was defined by conducting a detailed study of a reference design process, and key software elements for a CAD/CAM system have been defined, specifically for interactive design or experiment control processes. Further work is proceeding on executive, data management, geometry and graphics, and general utility software, and dynamic aspects of the programs being developed are outlined
Meng, Qingyuan; Haque, Amranul; Hexig, Bayar; Akaike, Toshihiro
2012-02-01
A simple culture system to achieve the differentiation of embryonic stem (ES) cells toward hepatocytes with high efficiency is crucial in providing a cell source for the medical application. In this study, we report the effect of a matrix-dependent enrichment of ES cell-derived hepatocytes using immobilized poly(N-p-vinylbenzyl-4-O-β-D-galactopyranosyl-D-gluconamide) (PVLA) with E-cadherin-IgG Fc (E-cad-Fc) as a galactose-carrying substratum. PVLA and E-cad-Fc were confirmed to be stably co-adsorbed onto polystyrene surface by quartz crystal microbalance (QCM). We showed that the E-cad-Fc/PVLA hybrid substratum was efficient in culturing primary hepatocytes and maintaining liver functions, on which the undifferentiated ES cells also maintained high proliferative capability. Furthermore, ES cell-derived hepatocytes on this hybrid matrix expressed elevated level of liver specific genes and functions together with early expression of definitive hepatocyte marker, asialoglycoprotein receptor (ASGPR). Finally, we isolated a high percentage of cells (about 60%) with ASGPR expression after re-seeding onto PVLA-coated surface, and observed the elimination of the poorly differentiated cells (Gata6(+) and Sox17(+)) and the ones toward another cell lineage (brachyury(+) and Pdx1(+)). The system uses a glycopolymer as an extracellular substratum for isolation and enrichment of ES cell-derived hepatocytes with adequate homogeneity and functionality. Copyright © 2011 Elsevier Ltd. All rights reserved.
Detecting Anomalous Insiders in Collaborative Information Systems
Chen, You; Nyemba, Steve; Malin, Bradley
2012-01-01
Collaborative information systems (CISs) are deployed within a diverse array of environments that manage sensitive information. Current security mechanisms detect insider threats, but they are ill-suited to monitor systems in which users function in dynamic teams. In this paper, we introduce the community anomaly detection system (CADS), an unsupervised learning framework to detect insider threats based on the access logs of collaborative environments. The framework is based on the observation that typical CIS users tend to form community structures based on the subjects accessed (e.g., patients’ records viewed by healthcare providers). CADS consists of two components: 1) relational pattern extraction, which derives community structures and 2) anomaly prediction, which leverages a statistical model to determine when users have sufficiently deviated from communities. We further extend CADS into MetaCADS to account for the semantics of subjects (e.g., patients’ diagnoses). To empirically evaluate the framework, we perform an assessment with three months of access logs from a real electronic health record (EHR) system in a large medical center. The results illustrate our models exhibit significant performance gains over state-of-the-art competitors. When the number of illicit users is low, MetaCADS is the best model, but as the number grows, commonly accessed semantics lead to hiding in a crowd, such that CADS is more prudent. PMID:24489520
Sánchez Pérez, A; Honrubia López, F M; Larrosa Poves, J M; Polo Llorens, V; Melcon Sánchez-Frieras, B
2001-09-01
To develop a lens planimetry technique for the optic disc using AutoCAD. To determine variability magnitude of the optic disc morphological measurements. We employed AutoCAD R.14.0 Autodesk: image acquisition, contour delimitation by multiple lines fitting or ellipse adjustment, image sectorialization and measurements quantification (optic disc and excavation, vertical diameters, optic disc area, excavation area, neuroretinal sector area and Beta atrophy area). Intraimage or operator and interimage o total reproducibility was studied by coefficient of variability (CV) (n=10) in normal and myopic optic discs. This technique allows to obtain optic disc measurement in 5 to 10 minutes time. Total or interimage variability of measurements introduced by one observer presents CV range from 1.18-4.42. Operator or intraimage measurement presents CV range from 0.30-4.21. Optic disc contour delimitation by ellipse adjustment achieved better reproducibility results than multiple lines adjustment in all measurements. Computer assisted AutoCAD planimetry is an interactive method to analyse the optic disc, feasible to incorporate to clinical practice. Reproducibility results are comparable to other analyzers in quantification optic disc morphology. Ellipse adjustment improves results in optic disc contours delimitation.
Vojdani, Mahroo; Torabi, Kianoosh; Atashkar, Berivan; Heidari, Hossein; Torabi Ardakani, Mahshid
2016-12-01
Marginal fitness is the most important criteria for evaluation of the clinical acceptability of a cast restoration. Marginal gap which is due to cement solubility and plaque retention is potentially detrimental to both tooth and periodontal tissues. This in vitro study aimed to evaluate the marginal and internal fit of cobalt- chromium (Co-Cr) copings fabricated by two different CAD/CAM systems: (CAD/ milling and CAD/ Ceramill Sintron). We prepared one machined standard stainless steel master model with following dimensions: 7 mm height, 5mm diameter, 90˚ shoulder marginal finish line with 1 mm width, 10˚ convergence angle and anti-rotational surface on the buccal aspect of the die. There were 10 copings produced from hard presintered Co-Cr blocks according to CAD/ Milling technique and ten copings from soft non- presintered Co-Cr blocks according to CAD/ Ceramill Sintron technique. Marginal and internal accuracies of copings were documented by the replica technique. Replicas were examined at ten reference points under a digital microscope (230X). The Student's t-test was used for statistical analysis. p < 0.001 was considered significant. Statistically significant differences existed between the groups ( p < 0.001). The CAD/milling group (hard copings) had a mean marginal discrepancy (MD) of 104 µm, axial discrepancy (AD) of 23 µm and occlusal discrepancy of 130 µm. For CAD/ Ceramill Sintron group, these values were 195 µm (MD), 46 µm (AD), and 232 µm (OD). Internal total discrepancy (ITD) for the CAD/milling group was 77 µm, whereas for the CAD/Ceramill Sintron group was 143 µm. Hard presintered Co-Cr copings had significantly higher marginal and internal accuracies compared to the soft non-presintered copings.
Integrated computer-aided design using minicomputers
NASA Technical Reports Server (NTRS)
Storaasli, O. O.
1980-01-01
Computer-Aided Design/Computer-Aided Manufacturing (CAD/CAM), a highly interactive software, has been implemented on minicomputers at the NASA Langley Research Center. CAD/CAM software integrates many formerly fragmented programs and procedures into one cohesive system; it also includes finite element modeling and analysis, and has been interfaced via a computer network to a relational data base management system and offline plotting devices on mainframe computers. The CAD/CAM software system requires interactive graphics terminals operating at a minimum of 4800 bits/sec transfer rate to a computer. The system is portable and introduces 'interactive graphics', which permits the creation and modification of models interactively. The CAD/CAM system has already produced designs for a large area space platform, a national transonic facility fan blade, and a laminar flow control wind tunnel model. Besides the design/drafting element analysis capability, CAD/CAM provides options to produce an automatic program tooling code to drive a numerically controlled (N/C) machine. Reductions in time for design, engineering, drawing, finite element modeling, and N/C machining will benefit productivity through reduced costs, fewer errors, and a wider range of configuration.
Computer Aided Detection (CAD) Systems for Mammography and the Use of GRID in Medicine
NASA Astrophysics Data System (ADS)
Lauria, Adele
It is well known that the most effective way to defeat breast cancer is early detection, as surgery and medical therapies are more efficient when the disease is diagnosed at an early stage. The principal diagnostic technique for breast cancer detection is X-ray mammography. Screening programs have been introduced in many European countries to invite women to have periodic radiological breast examinations. In such screenings, radiologists are often required to examine large numbers of mammograms with a double reading, that is, two radiologists examine the images independently and then compare their results. In this way an increment in sensitivity (the rate of correctly identified images with a lesion) of up to 15% is obtained.1,2 In most radiological centres, it is a rarity to find two radiologists to examine each report. In recent years different Computer Aided Detection (CAD) systems have been developed as a support to radiologists working in mammography: one may hope that the "second opinion" provided by CAD might represent a lower cost alternative to improve the diagnosis. At present, four CAD systems have obtained the FDA approval in the USA. † Studies3,4 show an increment in sensitivity when CAD systems are used. Freer and Ulissey in 2001 5 demonstrated that the use of a commercial CAD system (ImageChecker M1000, R2 Technology) increases the number of cancers detected up to 19.5% with little increment in recall rate. Ciatto et al.,5 in a study simulating a double reading with a commercial CAD system (SecondLook‡), showed a moderate increment in sensitivity while reducing specificity (the rate of correctly identified images without a lesion). Notwithstanding these optimistic results, there is an ongoing debate to define the advantages of the use of CAD as second reader: the main limits underlined, e.g., by Nishikawa6 are that retrospective studies are considered much too optimistic and that clinical studies must be performed to demonstrate a statistically significant benefit from the use of CAD.
Jiang, Yulei; Inciardi, Marc F; Edwards, Alexandra V; Papaioannou, John
2018-05-24
The purpose of this study was to compare diagnostic accuracy and interpretation time of screening automated breast ultrasound (ABUS) for women with dense breast tissue without and with use of a recently U.S. Food and Drug Administration-approved computer-aided detection (CAD) system for concurrent read. In a retrospective observer performance study, 18 radiologists interpreted a cancer-enriched set (i.e., cancer prevalence higher than in the original screening cohort) of 185 screening ABUS studies (52 with and 133 without breast cancer). These studies were from a large cohort of ABUS screened patients interpreted as BI-RADS density C or D. Each reader interpreted each case twice in a counterbalanced study, once without the CAD system and once with it, separated by 4 weeks. For each case, each reader identified abnormal findings and reported BI-RADS assessment category and level of suspicion for breast cancer. Interpretation time was recorded. Level of suspicion data were compared to evaluate diagnostic accuracy by means of the Dorfman-Berbaum-Metz method of jackknife with ANOVA ROC analysis. Interpretation times were compared by ANOVA. The ROC AUC was 0.848 with the CAD system, compared with 0.828 without it, for a difference of 0.020 (95% CI, -0.011 to 0.051) and was statistically noninferior to the AUC without the CAD system with respect to a margin of -0.05 (p = 0.000086). The mean interpretation time was 3 minutes 33 seconds per case without the CAD system and 2 minutes 24 seconds with it, for a difference of 1 minute 9 seconds saved (95% CI, 44-93 seconds; p = 0.000014), or a reduction in interpretation time to 67% of the time without the CAD system. Use of the concurrent-read CAD system for interpretation of screening ABUS studies of women with dense breast tissue who do not have symptoms is expected to make interpretation significantly faster and produce noninferior diagnostic accuracy compared with interpretation without the CAD system.
Computing Mass Properties From AutoCAD
NASA Technical Reports Server (NTRS)
Jones, A.
1990-01-01
Mass properties of structures computed from data in drawings. AutoCAD to Mass Properties (ACTOMP) computer program developed to facilitate quick calculations of mass properties of structures containing many simple elements in such complex configurations as trusses or sheet-metal containers. Mathematically modeled in AutoCAD or compatible computer-aided design (CAD) system in minutes by use of three-dimensional elements. Written in Microsoft Quick-Basic (Version 2.0).
The marginal fit of lithium disilicate crowns: Press vs. CAD/CAM.
Azar, Basel; Eckert, Steve; Kunkela, Josef; Ingr, Tomaš; Mounajjed, Radek
2018-01-01
This study aimed to compare the vertical marginal gap of teeth restored with lithium disilicate crowns fabricated using CAD/CAM or by pressed ceramic approach. Twenty mandibular third molar teeth were collected after surgical extractions and prepared to receive full veneer crowns. Teeth were optically scanned and lithium disilicate blocks were used to fabricate crowns using CAD/CAM technique. Polyvinyl siloxane impressions of the prepared teeth were made and monolithic pressed lithium disilicate crowns were fabricated. The marginal gap was measured using optical microscope at 200× magnification (Keyence VHX-5000, Japan). Statistical analysis was performed using Wilcoxon test. The lithium disilicate pressed crowns had significantly smaller (p = 0.006) marginal gaps (38 ± 12 μm) than the lithium disilicate CAD/CAM crowns (45 ± 12 μm). This research indicates that lithium disilicate crowns fabricated with the press technique have measurably smaller marginal gaps compared with those fabricated with CAD/CAM technique within in vitro environments. The marginal gaps achieved by the crowns across all groups were within a clinically acceptable range.
Free-form surface measuring method based on optical theodolite measuring system
NASA Astrophysics Data System (ADS)
Yu, Caili
2012-10-01
The measurement for single-point coordinate, length and large-dimension curved surface in industrial measurement can be achieved through forward intersection measurement by the theodolite measuring system composed of several optical theodolites and one computer. The measuring principle of flexible large-dimension three-coordinate measuring system made up of multiple (above two) optical theodolites and composition and functions of the system have been introduced in this paper. Especially for measurement of curved surface, 3D measured data of spatial free-form surface is acquired through the theodolite measuring system and the CAD model is formed through surface fitting to directly generate CAM processing data.
Application of computer-aided dispatch in law enforcement: An introductory planning guide
NASA Technical Reports Server (NTRS)
Sohn, R. L.; Gurfield, R. M.; Garcia, E. A.; Fielding, J. E.
1975-01-01
A set of planning guidelines for the application of computer-aided dispatching (CAD) to law enforcement is presented. Some essential characteristics and applications of CAD are outlined; the results of a survey of systems in the operational or planning phases are summarized. Requirements analysis, system concept design, implementation planning, and performance and cost modeling are described and demonstrated with numerous examples. Detailed descriptions of typical law enforcement CAD systems, and a list of vendor sources, are given in appendixes.
TopoCad - A unified system for geospatial data and services
NASA Astrophysics Data System (ADS)
Felus, Y. A.; Sagi, Y.; Regev, R.; Keinan, E.
2013-10-01
"E-government" is a leading trend in public sector activities in recent years. The Survey of Israel set as a vision to provide all of its services and datasets online. The TopoCad system is the latest software tool developed in order to unify a number of services and databases into one on-line and user friendly system. The TopoCad system is based on Web 1.0 technology; hence the customer is only a consumer of data. All data and services are accessible for the surveyors and geo-information professional in an easy and comfortable way. The future lies in Web 2.0 and Web 3.0 technologies through which professionals can upload their own data for quality control and future assimilation with the national database. A key issue in the development of this complex system was to implement a simple and easy (comfortable) user experience (UX). The user interface employs natural language dialog box in order to understand the user requirements. The system then links spatial data with alpha-numeric data in a flawless manner. The operation of the TopoCad requires no user guide or training. It is intuitive and self-taught. The system utilizes semantic engines and machine understanding technologies to link records from diverse databases in a meaningful way. Thus, the next generation of TopoCad will include five main modules: users and projects information, coordinates transformations and calculations services, geospatial data quality control, linking governmental systems and databases, smart forms and applications. The article describes the first stage of the TopoCad system and gives an overview of its future development.
Dhara, Ashis Kumar; Mukhopadhyay, Sudipta; Dutta, Anirvan; Garg, Mandeep; Khandelwal, Niranjan
2017-02-01
Visual information of similar nodules could assist the budding radiologists in self-learning. This paper presents a content-based image retrieval (CBIR) system for pulmonary nodules, observed in lung CT images. The reported CBIR systems of pulmonary nodules cannot be put into practice as radiologists need to draw the boundary of nodules during query formation and feature database creation. In the proposed retrieval system, the pulmonary nodules are segmented using a semi-automated technique, which requires a seed point on the nodule from the end-user. The involvement of radiologists in feature database creation is also reduced, as only a seed point is expected from radiologists instead of manual delineation of the boundary of the nodules. The performance of the retrieval system depends on the accuracy of the segmentation technique. Several 3D features are explored to improve the performance of the proposed retrieval system. A set of relevant shape and texture features are considered for efficient representation of the nodules in the feature space. The proposed CBIR system is evaluated for three configurations such as configuration-1 (composite rank of malignancy "1","2" as benign and "4","5" as malignant), configuration-2 (composite rank of malignancy "1","2", "3" as benign and "4","5" as malignant), and configuration-3 (composite rank of malignancy "1","2" as benign and "3","4","5" as malignant). Considering top 5 retrieved nodules and Euclidean distance metric, the precision achieved by the proposed method for configuration-1, configuration-2, and configuration-3 are 82.14, 75.91, and 74.27 %, respectively. The performance of the proposed CBIR system is close to the most recent technique, which is dependent on radiologists for manual segmentation of nodules. A computer-aided diagnosis (CAD) system is also developed based on CBIR paradigm. Performance of the proposed CBIR-based CAD system is close to performance of the CAD system using support vector machine.
Different CAD/CAM-processing routes for zirconia restorations: influence on fitting accuracy.
Kohorst, Philipp; Junghanns, Janet; Dittmer, Marc P; Borchers, Lothar; Stiesch, Meike
2011-08-01
The aim of the present in vitro study was to evaluate the influence of different processing routes on the fitting accuracy of four-unit zirconia fixed dental prostheses (FDPs) fabricated by computer-aided design/computer-aided manufacturing (CAD/CAM). Three groups of zirconia frameworks with ten specimens each were fabricated. Frameworks of one group (CerconCAM) were produced by means of a laboratory CAM-only system. The other frameworks were made with different CAD/CAM systems; on the one hand by in-laboratory production (CerconCAD/CAM) and on the other hand by centralized production in a milling center (Compartis) after forwarding geometrical data. Frameworks were then veneered with the recommended ceramics, and marginal accuracy was determined using a replica technique. Horizontal marginal discrepancy, vertical marginal discrepancy, absolute marginal discrepancy, and marginal gap were evaluated. Statistical analyses were performed by one-way analysis of variance (ANOVA), with the level of significance chosen at 0.05. Mean horizontal discrepancies ranged between 22 μm (CerconCAM) and 58 μm (Compartis), vertical discrepancies ranged between 63 μm (CerconCAD/CAM) and 162 μm (CerconCAM), and absolute marginal discrepancies ranged between 94 μm (CerconCAD/CAM) and 181 μm (CerconCAM). The marginal gap varied between 72 μm (CerconCAD/CAM) and 112 μm (CerconCAM, Compartis). Statistical analysis revealed that, with all measurements, the marginal accuracy of the zirconia FDPs was significantly influenced by the processing route used (p < 0.05). Within the limitations of this study, all restorations showed a clinically acceptable marginal accuracy; however, the results suggest that the CAD/CAM systems are more precise than the CAM-only system for the manufacture of four-unit FDPs.
2010-01-01
Background Cinnamyl Alcohol Dehydrogenase (CAD) proteins function in lignin biosynthesis and play a critical role in wood development and plant defense against stresses. Previous phylogenetic studies did not include genes from seedless plants and did not reflect the deep evolutionary history of this gene family. We reanalyzed the phylogeny of CAD and CAD-like genes using a representative dataset including lycophyte and bryophyte sequences. Many CAD/CAD-like genes do not seem to be associated with wood development under normal growth conditions. To gain insight into the functional evolution of CAD/CAD-like genes, we analyzed their expression in Populus plant tissues in response to feeding damage by gypsy moth larvae (Lymantria dispar L.). Expression of CAD/CAD-like genes in Populus tissues (xylem, leaves, and barks) was analyzed in herbivore-treated and non-treated plants by real time quantitative RT-PCR. Results CAD family genes were distributed in three classes based on sequence conservation. All the three classes are represented by seedless as well as seed plants, including the class of bona fide lignin pathway genes. The expression of some CAD/CAD-like genes that are not associated with xylem development were induced following herbivore damage in leaves, while other genes were induced in only bark or xylem tissues. Five of the CAD/CAD-like genes, however, showed a shift in expression from one tissue to another between non-treated and herbivore-treated plants. Systemic expression of the CAD/CAD-like genes was generally suppressed. Conclusions Our results indicated a correlation between the evolution of the CAD gene family and lignin and that the three classes of genes may have evolved in the ancestor of land plants. Our results also suggest that the CAD/CAD-like genes have evolved a diversity of expression profiles and potentially different functions, but that they are nonetheless co-regulated under stress conditions. PMID:20509918
Cury, Ricardo C; Abbara, Suhny; Achenbach, Stephan; Agatston, Arthur; Berman, Daniel S; Budoff, Matthew J; Dill, Karin E; Jacobs, Jill E; Maroules, Christopher D; Rubin, Geoffrey D; Rybicki, Frank J; Schoepf, U Joseph; Shaw, Leslee J; Stillman, Arthur E; White, Charles S; Woodard, Pamela K; Leipsic, Jonathon A
2016-09-01
The intent of CAD-RADS - Coronary Artery Disease Reporting and Data System is to create a standardized method to communicate findings of coronary CT angiography (coronary CTA) in order to facilitate decision-making regarding further patient management. The suggested CAD-RADS classification is applied on a per-patient basis and represents the highest-grade coronary artery lesion documented by coronary CTA. It ranges from CAD-RADS 0 (Zero) for the complete absence of stenosis and plaque to CAD-RADS 5 for the presence of at least one totally occluded coronary artery and should always be interpreted in conjunction with the impression found in the report. Specific recommendations are provided for further management of patients with stable or acute chest pain based on the CAD-RADS classification. The main goal of CAD-RADS is to standardize reporting of coronary CTA results and to facilitate communication of test results to referring physicians along with suggestions for subsequent patient management. In addition, CAD-RADS will provide a framework of standardization that may benefit education, research, peer-review and quality assurance with the potential to ultimately result in improved quality of care. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
CAD/CAM interface design of excimer laser micro-processing system
NASA Astrophysics Data System (ADS)
Jing, Liang; Chen, Tao; Zuo, Tiechuan
2005-12-01
Recently CAD/CAM technology has been gradually used in the field of laser processing. The excimer laser micro-processing system just identified G instruction before CAD/CAM interface was designed. However the course of designing a part with G instruction for users is too hard. The efficiency is low and probability of making errors is high. By secondary development technology of AutoCAD with Visual Basic, an application was developed to pick-up each entity's information in graph and convert them to each entity's processing parameters. Also an additional function was added into former controlling software to identify these processing parameters of each entity and realize continue processing of graphic. Based on the above CAD/CAM interface, Users can design a part in AutoCAD instead of using G instruction. The period of designing a part is sharply shortened. This new way of design greatly guarantees the processing parameters of the part is right and exclusive. The processing of complex novel bio-chip has been realized by this new function.
Xie, Joe X; Cury, Ricardo C; Leipsic, Jonathon; Crim, Matthew T; Berman, Daniel S; Gransar, Heidi; Budoff, Matthew J; Achenbach, Stephan; Ó Hartaigh, Bríain; Callister, Tracy Q; Marques, Hugo; Rubinshtein, Ronen; Al-Mallah, Mouaz H; Andreini, Daniele; Pontone, Gianluca; Cademartiri, Filippo; Maffei, Erica; Chinnaiyan, Kavitha; Raff, Gilbert; Hadamitzky, Martin; Hausleiter, Joerg; Feuchtner, Gudrun; Dunning, Allison; DeLago, Augustin; Kim, Yong-Jin; Kaufmann, Philipp A; Villines, Todd C; Chow, Benjamin J W; Hindoyan, Niree; Gomez, Millie; Lin, Fay Y; Jones, Erica; Min, James K; Shaw, Leslee J
2018-01-01
This study sought to assess clinical outcomes associated with the novel Coronary Artery Disease-Reporting and Data System (CAD-RADS) scores used to standardize coronary computed tomography angiography (CTA) reporting and their potential utility in guiding post-coronary CTA care. Clinical decision support is a major focus of health care policies aimed at improving guideline-directed care. Recently, CAD-RADS was developed to standardize coronary CTA reporting and includes clinical recommendations to facilitate patient management after coronary CTA. In the multinational CONFIRM (COronary CT Angiography EvaluatioN For Clinical Outcomes: An InteRnational Multicenter) registry, 5,039 patients without known coronary artery disease (CAD) underwent coronary CTA and were stratified by CAD-RADS scores, which rank CAD stenosis severity as 0 (0%), 1 (1% to 24%), 2 (25% to 49%), 3 (50% to 69%), 4A (70% to 99% in 1 to 2 vessels), 4B (70% to 99% in 3 vessels or ≥50% left main), or 5 (100%). Kaplan-Meier and multivariable Cox models were used to estimate all-cause mortality or myocardial infarction (MI). Receiver-operating characteristic (ROC) curves were used to compare CAD-RADS to the Duke CAD Index and traditional CAD classification. Referrals to invasive coronary angiography (ICA) after coronary CTA were also assessed. Cumulative 5-year event-free survival ranged from 95.2% to 69.3% for CAD-RADS 0 to 5 (p < 0.0001). Higher scores were associated with elevations in event risk (hazard ratio: 2.46 to 6.09; p < 0.0001). The ROC curve for prediction of death or MI was 0.7052 for CAD-RADS, which was noninferior to the Duke Index (0.7073; p = 0.893) and traditional CAD classification (0.7095; p = 0.783). ICA rates were 13% for CAD-RADS 0 to 2, 66% for CAD-RADS 3, and 84% for CAD-RADS ≥4A. For CAD-RADS 3, 58% of all catheterizations occurred within the first 30 days of follow-up. In a patient subset with available medication data, 57% of CAD-RADS 3 patients who received 30-day ICA were either asymptomatic or not receiving antianginal therapy at baseline, whereas only 32% had angina and were receiving medical therapy. CAD-RADS effectively identified patients at risk for adverse events. Frequent ICA use was observed among patients without severe CAD, many of whom were asymptomatic or not taking antianginal drugs. Incorporating CAD-RADS into coronary CTA reports may provide a novel opportunity to promote evidence-based care post-coronary CTA. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
CAD-Based Aerodynamic Design of Complex Configurations using a Cartesian Method
NASA Technical Reports Server (NTRS)
Nemec, Marian; Aftosmis, Michael J.; Pulliam, Thomas H.
2003-01-01
A modular framework for aerodynamic optimization of complex geometries is developed. By working directly with a parametric CAD system, complex-geometry models are modified nnd tessellated in an automatic fashion. The use of a component-based Cartesian method significantly reduces the demands on the CAD system, and also provides for robust and efficient flowfield analysis. The optimization is controlled using either a genetic or quasi-Newton algorithm. Parallel efficiency of the framework is maintained even when subject to limited CAD resources by dynamically re-allocating the processors of the flow solver. Overall, the resulting framework can explore designs incorporating large shape modifications and changes in topology.
Zhao, Linping; Patel, Pravin K; Cohen, Mimis
2012-07-01
Computer aided design and manufacturing (CAD/CAM) technology today is the standard in manufacturing industry. The application of the CAD/CAM technology, together with the emerging 3D medical images based virtual surgical planning (VSP) technology, to craniomaxillofacial reconstruction has been gaining increasing attention to reconstructive surgeons. This article illustrates the components, system and clinical management of the VSP and CAD/CAM technology including: data acquisition, virtual surgical and treatment planning, individual implant design and fabrication, and outcome assessment. It focuses primarily on the technical aspects of the VSP and CAD/CAM system to improve the predictability of the planning and outcome.
Shear Bond Strength of Repair Systems to New CAD/CAM Restorative Materials.
Üstün, Özlem; Büyükhatipoğlu, Işıl Keçik; Seçilmiş, Aslı
2016-11-23
To evaluate the bond strength of repair systems (Ceramic Repair, Clearfil Repair) to computer-aided design/computer-assisted machining (CAD/CAM) restorative materials (IPS e.max CAD, Vita Suprinity, Vita Enamic, Lava Ultimate). Thermally aged CAD/CAM restorative material specimens (5000 cycles between 5°C and 55°C) were randomly divided into two groups according to the repair system: Ceramic Repair (37% phosphoric acid + Monobond-S + Heliobond + Tetric N Ceram) or Clearfil Repair (40% phosphoric acid + mixture of Clearfil Porcelain Bond Activator and Clearfil SE Bond Primer + Clearfil SE Bond + Filtek Z250). The resin composite was light-cured on conditioned specimens. All specimens were stored in distilled water at 37°C for 24 hours and then additionally aged for 5000 thermal cycles. The shear bond strength test was performed using a universal testing machine (0.5 mm/min). Two-way ANOVA was used to detect significance differences according to the CAD/CAM material and composite repair system factors. Subgroup analyses were conducted using the least significant difference post-hoc test. The results of two-way ANOVA indicated that bond strength values varied according to the restorative materials (p < 0.05). No significant differences were observed between the CAD/CAM restorative materials (p > 0.05), except in the Vita Suprinity group (p < 0.05). Moreover, no differences were observed between the repair systems. Both the Clearfil and Ceramic repair systems used in the study allow for successful repairs. © 2016 by the American College of Prosthodontists.
[The study on fabrication of dental restoration using PMMA-ZrO2 composites via CAD/CAM].
Li, Shi-bao; Wang, Zhong-yi; Chen, Zhao-hui; Hu, Hai-feng; Tang, Li-hui; Ma, Chu-fan
2005-01-01
To obtain dental restorations by machining PMMA-ZrO2 organic-inorganic composites with the dental CAD/CAM system. Partially sintered Zirconia compacts (PSZC) were prepared via isostatic pressing and partially sintering, with Zirconia nanopowder as raw materials. PMMA-Zirconia organic-inorganic composites were prepared by vacuum infiltrating the prepolymerized MMA into the PSZC, followed by in-situ polymerization. The mechanical properties and machinability of composites were studied. The composites were machined on the dental CAD/CAM system to obtain dental restoration. At 71.44% TD of PSZC, the composite had a 3-point bending strength of (202.56 +/- 3.09) MPa, fracture toughness of (4.30 +/- 0.16) MPa.m(1/2), elasticity modulus of (58.71 +/- 1.98) GPa, and Vickers hardness of (3.82 +/- 0.34) GPa, respectively. A premolar crown was fabricated by CAD/CAM system in 16 mins, and was verisimilitude, without any cracks. The composite at 71.44% TD of PSZC has good mechanical properties and dental restorations can be manufactured by PMMA-Zirconia composites via dental CAD/CAM system.
NASA Technical Reports Server (NTRS)
Panczak, Tim; Ring, Steve; Welch, Mark
1999-01-01
Thermal engineering has long been left out of the concurrent engineering environment dominated by CAD (computer aided design) and FEM (finite element method) software. Current tools attempt to force the thermal design process into an environment primarily created to support structural analysis, which results in inappropriate thermal models. As a result, many thermal engineers either build models "by hand" or use geometric user interfaces that are separate from and have little useful connection, if any, to CAD and FEM systems. This paper describes the development of a new thermal design environment called the Thermal Desktop. This system, while fully integrated into a neutral, low cost CAD system, and which utilizes both FEM and FD methods, does not compromise the needs of the thermal engineer. Rather, the features needed for concurrent thermal analysis are specifically addressed by combining traditional parametric surface based radiation and FD based conduction modeling with CAD and FEM methods. The use of flexible and familiar temperature solvers such as SINDA/FLUINT (Systems Improved Numerical Differencing Analyzer/Fluid Integrator) is retained.
Li, Feng
2015-07-01
This review paper is based on our research experience in the past 30 years. The importance of radiologists' role is discussed in the development or evaluation of new medical images and of computer-aided detection (CAD) schemes in chest radiology. The four main topics include (1) introducing what diseases can be included in a research database for different imaging techniques or CAD systems and what imaging database can be built by radiologists, (2) understanding how radiologists' subjective judgment can be combined with technical objective features to improve CAD performance, (3) sharing our experience in the design of successful observer performance studies, and (4) finally, discussing whether the new images and CAD systems can improve radiologists' diagnostic ability in chest radiology. In conclusion, advanced imaging techniques and detection/classification of CAD systems have a potential clinical impact on improvement of radiologists' diagnostic ability, for both the detection and the differential diagnosis of various lung diseases, in chest radiology.
Integrated Computer-Aided Drafting Instruction (ICADI).
ERIC Educational Resources Information Center
Chen, C. Y.; McCampbell, David H.
Until recently, computer-aided drafting and design (CAD) systems were almost exclusively operated on mainframes or minicomputers and their cost prohibited many schools from offering CAD instruction. Today, many powerful personal computers are capable of performing the high-speed calculation and analysis required by the CAD application; however,…
Alqahtani, Fawaz
2017-01-01
Objective The purpose of this study was to determine the effect of two extraoral computer-aided design (CAD) and computer-aided manufacturing (CAM) systems, in comparison with conventional techniques, on the marginal fit of monolithic CAD/CAM lithium disilicate ceramic crowns. Study design This is an in vitro interventional study. Place and duration of study The study was carried out at the Department of Prosthodontics, School of Dentistry, Prince Sattam Bin Abdul-Aziz University, Saudi Arabia, from December 2015 to April 2016. Methodology A marginal gap of 60 lithium disilicate crowns was evaluated by scanning electron microscopy. In total, 20 pressable lithium disilicate (IPS e.max Press [Ivoclar Vivadent]) ceramic crowns were fabricated using the conventional lost-wax technique as a control group. The experimental all-ceramic crowns were produced based on a scan stone model and milled using two extraoral CAD/CAM systems: the Cerec group was fabricated using the Cerec CAD/CAM system, and the Trios group was fabricated using Trios CAD and milled using Wieland Zenotec CAM. One-way analysis of variance (ANOVA) and the Scheffe post hoc test were used for statistical comparison of the groups (α=0.05). Results The mean (±standard deviation) of the marginal gap of each group was as follows: the Control group was 91.15 (±15.35) µm, the Cerec group was 111.07 (±6.33) µm, and the Trios group was 60.17 (±11.09) µm. One-way ANOVA and the Scheffe post hoc test showed a statistically significant difference in the marginal gap between all groups. Conclusion It can be concluded from the current study that all-ceramic crowns, fabricated using the CAD/CAM system, show a marginal accuracy that is acceptable in clinical environments. The Trios CAD group displayed the smallest marginal gap. PMID:28352204
NASA Astrophysics Data System (ADS)
Gundreddy, Rohith Reddy; Tan, Maxine; Qui, Yuchen; Zheng, Bin
2015-03-01
The purpose of this study is to develop and test a new content-based image retrieval (CBIR) scheme that enables to achieve higher reproducibility when it is implemented in an interactive computer-aided diagnosis (CAD) system without significantly reducing lesion classification performance. This is a new Fourier transform based CBIR algorithm that determines image similarity of two regions of interest (ROI) based on the difference of average regional image pixel value distribution in two Fourier transform mapped images under comparison. A reference image database involving 227 ROIs depicting the verified soft-tissue breast lesions was used. For each testing ROI, the queried lesion center was systematically shifted from 10 to 50 pixels to simulate inter-user variation of querying suspicious lesion center when using an interactive CAD system. The lesion classification performance and reproducibility as the queried lesion center shift were assessed and compared among the three CBIR schemes based on Fourier transform, mutual information and Pearson correlation. Each CBIR scheme retrieved 10 most similar reference ROIs and computed a likelihood score of the queried ROI depicting a malignant lesion. The experimental results shown that three CBIR schemes yielded very comparable lesion classification performance as measured by the areas under ROC curves with the p-value greater than 0.498. However, the CBIR scheme using Fourier transform yielded the highest invariance to both queried lesion center shift and lesion size change. This study demonstrated the feasibility of improving robustness of the interactive CAD systems by adding a new Fourier transform based image feature to CBIR schemes.
Girod, Sabine; Schvartzman, Sara C; Gaudilliere, Dyani; Salisbury, Kenneth; Silva, Rebeka
2016-01-01
Computer-assisted surgical (CAS) planning tools are available for craniofacial surgery, but are usually based on computer-aided design (CAD) tools that lack the ability to detect the collision of virtual objects (i.e., fractured bone segments). We developed a CAS system featuring a sense of touch (haptic) that enables surgeons to physically interact with individual, patient-specific anatomy and immerse in a three-dimensional virtual environment. In this study, we evaluated initial user experience with our novel system compared to an existing CAD system. Ten surgery resident trainees received a brief verbal introduction to both the haptic and CAD systems. Users simulated mandibular fracture reduction in three clinical cases within a 15 min time limit for each system and completed a questionnaire to assess their subjective experience. We compared standard landmarks and linear and angular measurements between the simulated results and the actual surgical outcome and found that haptic simulation results were not significantly different from actual postoperative outcomes. In contrast, CAD results significantly differed from both the haptic simulation and actual postoperative results. In addition to enabling a more accurate fracture repair, the haptic system provided a better user experience than the CAD system in terms of intuitiveness and self-reported quality of repair.
Pulmonary nodule detection using a cascaded SVM classifier
NASA Astrophysics Data System (ADS)
Bergtholdt, Martin; Wiemker, Rafael; Klinder, Tobias
2016-03-01
Automatic detection of lung nodules from chest CT has been researched intensively over the last decades resulting also in several commercial products. However, solutions are adopted only slowly into daily clinical routine as many current CAD systems still potentially miss true nodules while at the same time generating too many false positives (FP). While many earlier approaches had to rely on rather few cases for development, larger databases become now available and can be used for algorithmic development. In this paper, we address the problem of lung nodule detection via a cascaded SVM classifier. The idea is to sequentially perform two classification tasks in order to select from an extremely large pool of potential candidates the few most likely ones. As the initial pool is allowed to contain thousands of candidates, very loose criteria could be applied during this pre-selection. In this way, the chances that a true nodule is falsely rejected as a candidate are reduced significantly. The final algorithm is trained and tested on the full LIDC/IDRI database. Comparison is done against two previously published CAD systems. Overall, the algorithm achieved sensitivity of 0.859 at 2.5 FP/volume where the other two achieved sensitivity values of 0.321 and 0.625, respectively. On low dose data sets, only slight increase in the number of FP/volume was observed, while the sensitivity was not affected.
Vojdani, Mahroo; Torabi, Kianoosh; Atashkar, Berivan; Heidari, Hossein; Torabi Ardakani, Mahshid
2016-01-01
Statement of the Problem: Marginal fitness is the most important criteria for evaluation of the clinical acceptability of a cast restoration. Marginal gap which is due to cement solubility and plaque retention is potentially detrimental to both tooth and periodontal tissues. Purpose: This in vitro study aimed to evaluate the marginal and internal fit of cobalt- chromium (Co-Cr) copings fabricated by two different CAD/CAM systems: (CAD/ milling and CAD/ Ceramill Sintron). Materials and Method: We prepared one machined standard stainless steel master model with following dimensions: 7 mm height, 5mm diameter, 90˚ shoulder marginal finish line with 1 mm width, 10˚ convergence angle and anti-rotational surface on the buccal aspect of the die. There were 10 copings produced from hard presintered Co-Cr blocks according to CAD/ Milling technique and ten copings from soft non- presintered Co-Cr blocks according to CAD/ Ceramill Sintron technique. Marginal and internal accuracies of copings were documented by the replica technique. Replicas were examined at ten reference points under a digital microscope (230X). The Student's t-test was used for statistical analysis. p< 0.001 was considered significant. Results: Statistically significant differences existed between the groups (p< 0.001). The CAD/milling group (hard copings) had a mean marginal discrepancy (MD) of 104 µm, axial discrepancy (AD) of 23 µm and occlusal discrepancy of 130 µm. For CAD/ Ceramill Sintron group, these values were 195 µm (MD), 46 µm (AD), and 232 µm (OD). Internal total discrepancy (ITD) for the CAD/milling group was 77 µm, whereas for the CAD/Ceramill Sintron group was 143 µm. Conclusion: Hard presintered Co-Cr copings had significantly higher marginal and internal accuracies compared to the soft non-presintered copings. PMID:27942545
NASA Astrophysics Data System (ADS)
B. Shokouhi, Shahriar; Fooladivanda, Aida; Ahmadinejad, Nasrin
2017-12-01
A computer-aided detection (CAD) system is introduced in this paper for detection of breast lesions in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). The proposed CAD system firstly compensates motion artifacts and segments the breast region. Then, the potential lesion voxels are detected and used as the initial seed points for the seeded region-growing algorithm. A new and robust region-growing algorithm incorporating with Fuzzy C-means (FCM) clustering and vesselness filter is proposed to segment any potential lesion regions. Subsequently, the false positive detections are reduced by applying a discrimination step. This is based on 3D morphological characteristics of the potential lesion regions and kinetic features which are fed to the support vector machine (SVM) classifier. The performance of the proposed CAD system is evaluated using the free-response operating characteristic (FROC) curve. We introduce our collected dataset that includes 76 DCE-MRI studies, 63 malignant and 107 benign lesions. The prepared dataset has been used to verify the accuracy of the proposed CAD system. At 5.29 false positives per case, the CAD system accurately detects 94% of the breast lesions.
Computer-aided diagnosis of alcoholism-related EEG signals.
Acharya, U Rajendra; S, Vidya; Bhat, Shreya; Adeli, Hojjat; Adeli, Amir
2014-12-01
Alcoholism is a severe disorder that affects the functionality of neurons in the central nervous system (CNS) and alters the behavior of the affected person. Electroencephalogram (EEG) signals can be used as a diagnostic tool in the evaluation of subjects with alcoholism. The neurophysiological interpretation of EEG signals in persons with alcoholism (PWA) is based on observation and interpretation of the frequency and power in their EEGs compared to EEG signals from persons without alcoholism. This paper presents a review of the known features of EEGs obtained from PWA and proposes that the impact of alcoholism on the brain can be determined by computer-aided analysis of EEGs through extracting the minute variations in the EEG signals that can differentiate the EEGs of PWA from those of nonaffected persons. The authors advance the idea of automated computer-aided diagnosis (CAD) of alcoholism by employing the EEG signals. This is achieved through judicious combination of signal processing techniques such as wavelet, nonlinear dynamics, and chaos theory and pattern recognition and classification techniques. A CAD system is cost-effective and efficient and can be used as a decision support system by physicians in the diagnosis and treatment of alcoholism especially those who do not specialize in alcoholism or neurophysiology. It can also be of great value to rehabilitation centers to assess PWA over time and to monitor the impact of treatment aimed at minimizing or reversing the effects of the disease on the brain. A CAD system can be used to determine the extent of alcoholism-related changes in EEG signals (low, medium, high) and the effectiveness of therapeutic plans. Copyright © 2014 Elsevier Inc. All rights reserved.
Space crew radiation exposure analysis system based on a commercial stand-alone CAD system
NASA Technical Reports Server (NTRS)
Appleby, Matthew H.; Golightly, Michael J.; Hardy, Alva C.
1992-01-01
Major improvements have recently been completed in the approach to spacecraft shielding analysis. A Computer-Aided Design (CAD)-based system has been developed for determining the shielding provided to any point within or external to the spacecraft. Shielding analysis is performed using a commercially available stand-alone CAD system and a customized ray-tracing subroutine contained within a standard engineering modeling software package. This improved shielding analysis technique has been used in several vehicle design projects such as a Mars transfer habitat, pressurized lunar rover, and the redesigned Space Station. Results of these analyses are provided to demonstrate the applicability and versatility of the system.
Liao, Katherine P; Ananthakrishnan, Ashwin N; Kumar, Vishesh; Xia, Zongqi; Cagan, Andrew; Gainer, Vivian S; Goryachev, Sergey; Chen, Pei; Savova, Guergana K; Agniel, Denis; Churchill, Susanne; Lee, Jaeyoung; Murphy, Shawn N; Plenge, Robert M; Szolovits, Peter; Kohane, Isaac; Shaw, Stanley Y; Karlson, Elizabeth W; Cai, Tianxi
2015-01-01
Typically, algorithms to classify phenotypes using electronic medical record (EMR) data were developed to perform well in a specific patient population. There is increasing interest in analyses which can allow study of a specific outcome across different diseases. Such a study in the EMR would require an algorithm that can be applied across different patient populations. Our objectives were: (1) to develop an algorithm that would enable the study of coronary artery disease (CAD) across diverse patient populations; (2) to study the impact of adding narrative data extracted using natural language processing (NLP) in the algorithm. Additionally, we demonstrate how to implement CAD algorithm to compare risk across 3 chronic diseases in a preliminary study. We studied 3 established EMR based patient cohorts: diabetes mellitus (DM, n = 65,099), inflammatory bowel disease (IBD, n = 10,974), and rheumatoid arthritis (RA, n = 4,453) from two large academic centers. We developed a CAD algorithm using NLP in addition to structured data (e.g. ICD9 codes) in the RA cohort and validated it in the DM and IBD cohorts. The CAD algorithm using NLP in addition to structured data achieved specificity >95% with a positive predictive value (PPV) 90% in the training (RA) and validation sets (IBD and DM). The addition of NLP data improved the sensitivity for all cohorts, classifying an additional 17% of CAD subjects in IBD and 10% in DM while maintaining PPV of 90%. The algorithm classified 16,488 DM (26.1%), 457 IBD (4.2%), and 245 RA (5.0%) with CAD. In a cross-sectional analysis, CAD risk was 63% lower in RA and 68% lower in IBD compared to DM (p<0.0001) after adjusting for traditional cardiovascular risk factors. We developed and validated a CAD algorithm that performed well across diverse patient populations. The addition of NLP into the CAD algorithm improved the sensitivity of the algorithm, particularly in cohorts where the prevalence of CAD was low. Preliminary data suggest that CAD risk was significantly lower in RA and IBD compared to DM.
Liao, Katherine P.; Ananthakrishnan, Ashwin N.; Kumar, Vishesh; Xia, Zongqi; Cagan, Andrew; Gainer, Vivian S.; Goryachev, Sergey; Chen, Pei; Savova, Guergana K.; Agniel, Denis; Churchill, Susanne; Lee, Jaeyoung; Murphy, Shawn N.; Plenge, Robert M.; Szolovits, Peter; Kohane, Isaac; Shaw, Stanley Y.; Karlson, Elizabeth W.; Cai, Tianxi
2015-01-01
Background Typically, algorithms to classify phenotypes using electronic medical record (EMR) data were developed to perform well in a specific patient population. There is increasing interest in analyses which can allow study of a specific outcome across different diseases. Such a study in the EMR would require an algorithm that can be applied across different patient populations. Our objectives were: (1) to develop an algorithm that would enable the study of coronary artery disease (CAD) across diverse patient populations; (2) to study the impact of adding narrative data extracted using natural language processing (NLP) in the algorithm. Additionally, we demonstrate how to implement CAD algorithm to compare risk across 3 chronic diseases in a preliminary study. Methods and Results We studied 3 established EMR based patient cohorts: diabetes mellitus (DM, n = 65,099), inflammatory bowel disease (IBD, n = 10,974), and rheumatoid arthritis (RA, n = 4,453) from two large academic centers. We developed a CAD algorithm using NLP in addition to structured data (e.g. ICD9 codes) in the RA cohort and validated it in the DM and IBD cohorts. The CAD algorithm using NLP in addition to structured data achieved specificity >95% with a positive predictive value (PPV) 90% in the training (RA) and validation sets (IBD and DM). The addition of NLP data improved the sensitivity for all cohorts, classifying an additional 17% of CAD subjects in IBD and 10% in DM while maintaining PPV of 90%. The algorithm classified 16,488 DM (26.1%), 457 IBD (4.2%), and 245 RA (5.0%) with CAD. In a cross-sectional analysis, CAD risk was 63% lower in RA and 68% lower in IBD compared to DM (p<0.0001) after adjusting for traditional cardiovascular risk factors. Conclusions We developed and validated a CAD algorithm that performed well across diverse patient populations. The addition of NLP into the CAD algorithm improved the sensitivity of the algorithm, particularly in cohorts where the prevalence of CAD was low. Preliminary data suggest that CAD risk was significantly lower in RA and IBD compared to DM. PMID:26301417
Hamza, Tamer A; Sherif, Rana M
2017-06-01
Dental laboratories use different computer-aided design and computer-aided manufacturing (CAD-CAM) systems to fabricate fixed prostheses; however, limited evidence is available concerning which system provides the best marginal discrepancy. The purpose of this in vitro study was to evaluate the marginal fit of 5 different monolithic zirconia restorations milled with different CAD-CAM systems. Thirty monolithic zirconia crowns were fabricated on a custom-designed stainless steel die and were divided into 5 groups according to the type of monolithic zirconia crown and the CAD-CAM system used: group TZ, milled with an MCXL milling machine; group CZ, translucent zirconia milled with a motion milling machine; group ZZ, zirconia milled with a dental milling unit; group PZ, translucent zirconia milled with a zirconia milling unit; and group BZ, solid zirconia milled using an S1 VHF milling machine. The marginal fit was measured with a binocular microscope at an original magnification of ×100. The results were tabulated and statistically analyzed with 1-way ANOVA and post hoc surface range test, and pairwise multiple comparisons were made using Bonferroni correction (α=.05). The type of CAD-CAM used affected the marginal fit of the monolithic restoration. The mean (±SD) highest marginal discrepancy was recorded in group TZI at 39.3 ±2.3 μm, while the least mean marginal discrepancy was recorded in group IZ (22.8 ±8.9 μm). The Bonferroni post hoc test showed that group TZI was significantly different from all other groups tested (P<.05). Within the limitation of this in vitro study, all tested CAD-CAM systems produced monolithic zirconia restorations with clinically acceptable marginal discrepancies; however, the CAD-CAM system with the 5-axis milling unit produced the best marginal fit. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Borysov, Maksym; Mogiliantseva, Tatiana
2016-01-01
The aim of this study is to evaluate the effect of a Schroth Best Practice® program in an out-patient regimen on the signs of scoliosis in patients with adolescent idiopathic scoliosis (hereafter referred to as AIS). The second aim is to evaluate in-brace correction with the Gensingen Brace® in the first sample of patients with AIS. Both authors have undergone training in this special approach to scoliosis rehabilitation. The first author has undergone PT (physical therapy) and CAD-CAM (computer-aided design and manufacturing)bracing training, the second author PT training. 23 patients with AIS, 19 girls and 4 boys, with an average age of 13.6 years, average Risser sign of 2.52 and an average Cobb angle of 36.9 degrees (20-88 degrees), underwent an out-patient Schroth Best Practice® program with an intensity of two days a week of 2 x 60 min sessions/day. The angle of trunk rotation (ATR) was measured before and after the course. Eleven of the patients were fit with Gensingen Braces®. Braces were produced via CAD-CAM. In-brace correction was measured and compared with initial data. After an out-patient Schroth Best Practice® program ATR was reduced significantly from 9.58 degrees to 7.47 degrees in thoracic and from 8.9 to 6.6 degrees in lumbar. An average in-brace correction of 59% was achieved in CADCAM braces. The results achieved with out-patient rehabilitation in the investigations published previously are repeatable. The deformity of the trunk can be reduced significantly after out-patient rehabilitation according to Schroth Best Practice® standards. In-brace correction comparable with published results on CAD-CAM bracing can be achieved in braces according to Gensingen® standards after appropriate training. Out-patient rehabilitation following the Schroth Best Practice® standards seems to provide an improvement of signs of scoliosis patients in this study using a pre-/post prospective design. The results of the recent studies on Schroth Best Practice® program seem to be repeatable. Following appropriate training, the in-brace corrections achieved with the CAD / CAM technology can be compared to the in-brace corrections as published in recent literature. CAD / CAM allows for repeatable results globally.
NASA Astrophysics Data System (ADS)
Sánchez, Clara I.; Niemeijer, Meindert; Kockelkorn, Thessa; Abràmoff, Michael D.; van Ginneken, Bram
2009-02-01
Computer-aided Diagnosis (CAD) systems for the automatic identification of abnormalities in retinal images are gaining importance in diabetic retinopathy screening programs. A huge amount of retinal images are collected during these programs and they provide a starting point for the design of machine learning algorithms. However, manual annotations of retinal images are scarce and expensive to obtain. This paper proposes a dynamic CAD system based on active learning for the automatic identification of hard exudates, cotton wool spots and drusen in retinal images. An uncertainty sampling method is applied to select samples that need to be labeled by an expert from an unlabeled set of 4000 retinal images. It reduces the number of training samples needed to obtain an optimum accuracy by dynamically selecting the most informative samples. Results show that the proposed method increases the classification accuracy compared to alternative techniques, achieving an area under the ROC curve of 0.87, 0.82 and 0.78 for the detection of hard exudates, cotton wool spots and drusen, respectively.
CAD-centric Computation Management System for a Virtual TBM
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ramakanth Munipalli; K.Y. Szema; P.Y. Huang
HyPerComp Inc. in research collaboration with TEXCEL has set out to build a Virtual Test Blanket Module (VTBM) computational system to address the need in contemporary fusion research for simulating the integrated behavior of the blanket, divertor and plasma facing components in a fusion environment. Physical phenomena to be considered in a VTBM will include fluid flow, heat transfer, mass transfer, neutronics, structural mechanics and electromagnetics. We seek to integrate well established (third-party) simulation software in various disciplines mentioned above. The integrated modeling process will enable user groups to interoperate using a common modeling platform at various stages of themore » analysis. Since CAD is at the core of the simulation (as opposed to computational meshes which are different for each problem,) VTBM will have a well developed CAD interface, governing CAD model editing, cleanup, parameter extraction, model deformation (based on simulation,) CAD-based data interpolation. In Phase-I, we built the CAD-hub of the proposed VTBM and demonstrated its use in modeling a liquid breeder blanket module with coupled MHD and structural mechanics using HIMAG and ANSYS. A complete graphical user interface of the VTBM was created, which will form the foundation of any future development. Conservative data interpolation via CAD (as opposed to mesh-based transfer), the regeneration of CAD models based upon computed deflections, are among the other highlights of phase-I activity.« less
Takaba, Masayuki; Tanaka, Shinpei; Ishiura, Yuichi; Baba, Kazuyoshi
2013-07-01
Recently, fixed dental prostheses (FDPs) with a hybrid structure of CAD/CAM porcelain crowns adhered to a CAD/CAM zirconia framework (PAZ) have been developed. The aim of this report was to describe the clinical application of a newly developed implant-supported FDP fabrication system, which uses PAZ, and to evaluate the outcome after a maximum application period of 36 months. Implants were placed in three patients with edentulous areas in either the maxilla or mandible. After the implant fixtures had successfully integrated with bone, gold-platinum alloy or zirconia custom abutments were first fabricated. Zirconia framework wax-up was performed on the custom abutments, and the CAD/CAM zirconia framework was prepared using the CAD/CAM system. Next, wax-up was performed on working models for porcelain crown fabrication, and CAD/CAM porcelain crowns were fabricated. The CAD/CAM zirconia frameworks and CAD/CAM porcelain crowns were bonded using adhesive resin cement, and the PAZ was cemented. Cementation of the implant superstructure improved the esthetics and masticatory efficiency in all patients. No undesirable outcomes, such as superstructure chipping, stomatognathic dysfunction, or periimplant bone resorption, were observed in any of the patients. PAZ may be a potential solution for ceramic-related clinical problems such as chipping and fracture and associated complicated repair procedures in implant-supported FDPs. © 2012 by the American College of Prosthodontists.
Cury, Ricardo C; Abbara, Suhny; Achenbach, Stephan; Agatston, Arthur; Berman, Daniel S; Budoff, Matthew J; Dill, Karin E; Jacobs, Jill E; Maroules, Christopher D; Rubin, Geoffrey D; Rybicki, Frank J; Schoepf, U Joseph; Shaw, Leslee J; Stillman, Arthur E; White, Charles S; Woodard, Pamela K; Leipsic, Jonathon A
2016-01-01
The intent of CAD-RADS - Coronary Artery Disease Reporting and Data System is to create a standardized method to communicate findings of coronary CT angiography (coronary CTA) in order to facilitate decision-making regarding further patient management. The suggested CAD-RADS classification is applied on a per-patient basis and represents the highest-grade coronary artery lesion documented by coronary CTA. It ranges from CAD-RADS 0 (Zero) for the complete absence of stenosis and plaque to CAD-RADS 5 for the presence of at least one totally occluded coronary artery and should always be interpreted in conjunction with the impression found in the report. Specific recommendations are provided for further management of patients with stable or acute chest pain based on the CAD-RADS classification. The main goal of CAD-RADS is to standardize reporting of coronary CTA results and to facilitate communication of test results to referring physicians along with suggestions for subsequent patient management. In addition, CAD-RADS will provide a framework of standardization that may benefit education, research, peer-review and quality assurance with the potential to ultimately result in improved quality of care. Copyright © 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.
Immunoglobulins against Tyrosine Nitrated Epitopes in Coronary Artery Disease
Thomson, Leonor; Tenopoulou, Margarita; Lightfoot, Richard; Tsika, Epida; Parastatidis, Ioannis; Martinez, Marissa; Greco, Todd M.; Doulias, Paschalis-Thomas; Wu, Yuping; Tang, W. H. Wilson; Hazen, Stanley L.; Ischiropoulos, Harry
2012-01-01
Background Several lines of evidence support a pathophysiological role of immunity in atherosclerosis. Tyrosine nitrated proteins, a footprint of oxygen and nitrogen derived oxidants generated by cells of the immune system, are enriched in atheromatous lesions and in circulation of coronary artery disease (CAD) subjects. However, the consequences of possible immune reactions triggered by the presence of nitrated proteins in subjects with clinically documented atherosclerosis have not been explored. Methods and Results Specific immunoglobulins that recognize 3-nitrotyrosine epitopes were identified in human lesions, as well as in circulation of CAD subjects. The levels of circulating immunoglobulins against 3-nitrotyrosine epitopes were quantified in CAD patients (n=374) and subjects without CAD (non CAD controls, n=313). A ten-fold increase in the mean level of circulating immunoglobulins against protein-bound 3-nitrotyrosine was documented in the CAD subjects (3.75 ± 1.8 μg antibody Eq/mL plasma vs. 0.36 ± 0.8 μg antibody Eq/mL plasma), and was strongly associated with angiographic evidence of significant CAD. Conclusions The results of this cross sectional study suggest that post-translational modification of proteins via nitration within atherosclerotic plaque-laden arteries and in circulation serve as neoepitopes for elaboration of immunoglobulins, thereby providing an association between oxidant production and the activation of the immune system in CAD. PMID:23081989
PACS-Based Computer-Aided Detection and Diagnosis
NASA Astrophysics Data System (ADS)
Huang, H. K. (Bernie); Liu, Brent J.; Le, Anh HongTu; Documet, Jorge
The ultimate goal of Picture Archiving and Communication System (PACS)-based Computer-Aided Detection and Diagnosis (CAD) is to integrate CAD results into daily clinical practice so that it becomes a second reader to aid the radiologist's diagnosis. Integration of CAD and Hospital Information System (HIS), Radiology Information System (RIS) or PACS requires certain basic ingredients from Health Level 7 (HL7) standard for textual data, Digital Imaging and Communications in Medicine (DICOM) standard for images, and Integrating the Healthcare Enterprise (IHE) workflow profiles in order to comply with the Health Insurance Portability and Accountability Act (HIPAA) requirements to be a healthcare information system. Among the DICOM standards and IHE workflow profiles, DICOM Structured Reporting (DICOM-SR); and IHE Key Image Note (KIN), Simple Image and Numeric Report (SINR) and Post-processing Work Flow (PWF) are utilized in CAD-HIS/RIS/PACS integration. These topics with examples are presented in this chapter.
Representing spatial information in a computational model for network management
NASA Technical Reports Server (NTRS)
Blaisdell, James H.; Brownfield, Thomas F.
1994-01-01
While currently available relational database management systems (RDBMS) allow inclusion of spatial information in a data model, they lack tools for presenting this information in an easily comprehensible form. Computer-aided design (CAD) software packages provide adequate functions to produce drawings, but still require manual placement of symbols and features. This project has demonstrated a bridge between the data model of an RDBMS and the graphic display of a CAD system. It is shown that the CAD system can be used to control the selection of data with spatial components from the database and then quickly plot that data on a map display. It is shown that the CAD system can be used to extract data from a drawing and then control the insertion of that data into the database. These demonstrations were successful in a test environment that incorporated many features of known working environments, suggesting that the techniques developed could be adapted for practical use.
An esthetics rehabilitation with computer-aided design/ computer-aided manufacturing technology.
Mazaro, Josá Vitor Quinelli; de Mello, Caroline Cantieri; Zavanelli, Adriana Cristina; Santiago, Joel Ferreira; Amoroso, Andressa Paschoal; Pellizzer, Eduardo Piza
2014-07-01
This paper describes a case of a rehabilitation involving Computer Aided Design/Computer Aided Manufacturing (CAD-CAM) system in implant supported and dental supported prostheses using zirconia as framework. The CAD-CAM technology has developed considerably over last few years, becoming a reality in dental practice. Among the widely used systems are the systems based on zirconia which demonstrate important physical and mechanical properties of high strength, adequate fracture toughness, biocompatibility and esthetics, and are indicated for unitary prosthetic restorations and posterior and anterior framework. All the modeling was performed by using CAD-CAM system and prostheses were cemented using resin cement best suited for each situation. The rehabilitation of the maxillary arch using zirconia framework demonstrated satisfactory esthetic and functional results after a 12-month control and revealed no biological and technical complications. This article shows the important of use technology CAD/CAM in the manufacture of dental prosthesis and implant-supported.
Issues in assessing multi-institutional performance of BI-RADS-based CAD systems
NASA Astrophysics Data System (ADS)
Markey, Mia K.; Lo, Joseph Y.
2005-04-01
The purpose of this study was to investigate factors that impact the generalization of breast cancer computer-aided diagnosis (CAD) systems that utilize the Breast Imaging Reporting and Data System (BI-RADS). Data sets from four institutions were analyzed: Duke University Medical Center, University of Pennsylvania Medical Center, Massachusetts General Hospital, and Wake Forest University. The latter two data sets are subsets of the Digital Database for Screening Mammography. Each data set consisted of descriptions of mammographic lesions according to the BI-RADS lexicon, patient age, and pathology status (benign/malignant). Models were developed to predict pathology status from the BI-RADS descriptors and the patient age. Comparisons between the models built on data from the different institutions were made in terms of empirical (non-parametric) receiver operating characteristic (ROC) curves. Results suggest that BI-RADS-based CAD systems focused on specific classes of lesions may be more generally applicable than models that cover several lesion types. However, better generalization was seen in terms of the area under the ROC curve than in the partial area index (>90% sensitivity). Previous studies have illustrated the challenges in translating a BI-RADS-based CAD system from one institution to another. This study provides new insights into possible approaches to improve the generalization of BI-RADS-based CAD systems.
Noise detection in heart sound recordings.
Zia, Mohammad K; Griffel, Benjamin; Fridman, Vladimir; Saponieri, Cesare; Semmlow, John L
2011-01-01
Coronary artery disease (CAD) is the leading cause of death in the United States. Although progression of CAD can be controlled using drugs and diet, it is usually detected in advanced stages when invasive treatment is required. Current methods to detect CAD are invasive and/or costly, hence not suitable as a regular screening tool to detect CAD in early stages. Currently, we are developing a noninvasive and cost-effective system to detect CAD using the acoustic approach. This method identifies sounds generated by turbulent flow through partially narrowed coronary arteries to detect CAD. The limiting factor of this method is sensitivity to noises commonly encountered in the clinical setting. Because the CAD sounds are faint, these noises can easily obscure the CAD sounds and make detection impossible. In this paper, we propose a method to detect and eliminate noise encountered in the clinical setting using a reference channel. We show that our method is effective in detecting noise, which is essential to the success of the acoustic approach.
Computer-aided detection in musculoskeletal projection radiography: A systematic review.
Gundry, M; Knapp, K; Meertens, R; Meakin, J R
2018-05-01
To investigated the accuracy of computer-aided detection (CAD) software in musculoskeletal projection radiography via a systematic review. Following selection screening, eligible studies were assessed for bias, and had their study characteristics extracted resulting in 22 studies being included. Of these 22 three studies had tested their CAD software in a clinical setting; the first study investigated vertebral fractures, reporting a sensitivity score of 69.3% with CAD, compared to 59.8% sensitivity without CAD. The second study tested dental caries diagnosis producing a sensitivity score of 68.8% and specificity of 94.1% with CAD, compared to sensitivity of 39.3% and specificity of 96.7% without CAD. The third indicated osteoporotic cases based on CAD, resulting in 100% sensitivity and 81.3% specificity. The current evidence reported shows a lack of development into the clinical testing phase; however the research does show future promise in the variation of different CAD systems. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.
Evolution of Geometric Sensitivity Derivatives from Computer Aided Design Models
NASA Technical Reports Server (NTRS)
Jones, William T.; Lazzara, David; Haimes, Robert
2010-01-01
The generation of design parameter sensitivity derivatives is required for gradient-based optimization. Such sensitivity derivatives are elusive at best when working with geometry defined within the solid modeling context of Computer-Aided Design (CAD) systems. Solid modeling CAD systems are often proprietary and always complex, thereby necessitating ad hoc procedures to infer parameter sensitivity. A new perspective is presented that makes direct use of the hierarchical associativity of CAD features to trace their evolution and thereby track design parameter sensitivity. In contrast to ad hoc methods, this method provides a more concise procedure following the model design intent and determining the sensitivity of CAD geometry directly to its respective defining parameters.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Womersley, J.; DiGiacomo, N.; Killian, K.
1990-04-01
Detailed detector design has traditionally been divided between engineering optimization for structural integrity and subsequent physicist evaluation. The availability of CAD systems for engineering design enables the tasks to be integrated by providing tools for particle simulation within the CAD system. We believe this will speed up detector design and avoid problems due to the late discovery of shortcomings in the detector. This could occur because of the slowness of traditional verification techniques (such as detailed simulation with GEANT). One such new particle simulation tool is described. It is being used with the I-DEAS CAD package for SSC detector designmore » at Martin-Marietta Astronautics and is to be released through the SSC Laboratory.« less
Update of patient-specific maxillofacial implant.
Owusu, James A; Boahene, Kofi
2015-08-01
Patient-specific implant (PSI) is a personalized approach to reconstructive and esthetic surgery. This is particularly useful in maxillofacial surgery in which restoring the complex three-dimensional (3D) contour can be quite challenging. In certain situations, the best results can only be achieved with implants custom-made to fit a particular need. Significant progress has been made over the past decade in the design and manufacture of maxillofacial PSIs. Computer-aided design (CAD)/computer-aided manufacturing (CAM) technology is rapidly advancing and has provided new options for fabrication of PSIs with better precision. Maxillofacial PSIs can now be designed using preoperative imaging data as input into CAD software. The designed implant is then fabricated using a CAM technique such as 3D printing. This approach increases precision and decreases or completely eliminates the need for intraoperative modification of implants. The use of CAD/CAM-produced PSIs for maxillofacial reconstruction and augmentation can significantly improve contour outcomes and decrease operating time. CAD/CAM technology allows timely and precise fabrication of maxillofacial PSIs. This approach is gaining increasing popularity in maxillofacial reconstructive surgery. Continued advances in CAD technology and 3D printing are bound to improve the cost-effectiveness and decrease the production time of maxillofacial PSIs.
Cardiac SPECT/CCTA hybrid imaging : One answer to two questions?
Kaufmann, P A; Buechel, R R
2016-08-01
Noninvasive cardiac imaging has witnessed tremendous advances in the recent past, particularly with regard to coronary computed tomography angiography (CCTA) where substantial improvements in image quality have been achieved while at the same time patients' radiation dose exposure has been reduced to the sub-millisievert range. Similarly, for single-photon emission computed tomography (SPECT) the introduction of novel cadmium-zinc-telluride-based semiconductor detectors has significantly improved system sensitivity and image quality, enabling fast image acquisition within less than 2-3 min or reduction of radiation dose exposure to less than 5 mSv. However, neither imaging modality alone is able to fully cover the two aspects of coronary artery disease (CAD), that is, morphology and function. Both modalities have distinct advantages and shortcomings: While CCTA may prove a superb modality for excluding CAD through its excellent negative predictive value, it does not allow for assessment of hemodynamic relevance if obstructive coronary lesions are detected. Conversely, SPECT myocardial perfusion imaging cannot provide any information on the presence or absence of subclinical coronary atherosclerosis. This article aims to highlight the great potential of cardiac hybrid imaging that allows for a comprehensive evaluation of CAD through combination of both morphological and functional information by fusing SPECT with CCTA.
Tam, James; Ahmad, Imad A Haidar; Blasko, Andrei
2018-06-05
A four parameter optimization of a stability indicating method for non-chromophoric degradation products of 1,2-distearoyl-sn-glycero-3-phosphocholine (DSPC), 1-stearoyl-sn-glycero-3-phosphocholine and 2-stearoyl-sn-glycero-3-phosphocholine was achieved using a reverse phase liquid chromatography-charged aerosol detection (RPLC-CAD) technique. Using the hydrophobic subtraction model of selectivity, a core-shell, polar embedded RPLC column was selected followed by gradient-temperature optimization, resulting in ideal relative peak placements for a robust, stability indicating separation. The CAD instrument parameters, power function value (PFV) and evaporator temperature were optimized for lysophosphatidylcholines to give UV absorbance detector-like linearity performance within a defined concentration range. The two lysophosphatidylcholines gave the same response factor in the selected conditions. System specific power function values needed to be set for the two RPLC-CAD instruments used. A custom flow-divert profile, sending only a portion of the column effluent to the detector, was necessary to mitigate detector response drifting effects. The importance of the PFV optimization for each instrument of identical build and how to overcome recovery issues brought on by the matrix effects from the lipid-RP stationary phase interaction is reported. Copyright © 2018 Elsevier B.V. All rights reserved.
PLM in the context of the maritime virtual education
NASA Astrophysics Data System (ADS)
Raicu, Alexandra; Oanta, Emil M.
2016-12-01
This paper presents new approaches regarding the use of Product Lifecycle Management concept to achieve knowledge integration of the academic disciplines in the maritime education context. The philosophy of the educational system is now changing faster worldwide and it is in a continuous developing process. There is a demand to develop modern educational facilities for CAD/CAE/CAM training of the future maritime engineers, which offers collaborative environments between the academic disciplines and the teachers. It is well known that the students must understand the importance of the connectivity between the academic disciplines and the computer aided methods to interface them. Thus, besides the basic knowledge and competences acquired from the CAD courses, students learn how to increase the design productivity, to create a parametric design, the original instruments of automatic design, 3D printing methods, how to interface the CAD/CAE/CAM applications. As an example, the Strength of Materials discipline briefly presents alternate computer aided methods to compute the geometrical characteristics of the cross sections using the CAD geometry, creation the free body diagrams and presentation the deflected shapes of various educational models, including the rotational effect when the forces are not applied in the shear center, using the results of the FEM applications. During the computer aided engineering academic disciplines, after the students design and analyze a virtual 3D model they can convert it into a physical object using 3D printing method. Constanta Maritime University offers a full understanding of the concept of Product Lifecycle Management, collaborative creation, management and dissemination.
Gray, Rachel; Gougoutas, Alexander; Nguyen, Vinh; Taylor, Jesse; Bastidas, Nicholas
2017-06-01
Virtual Surgical Planning (VSP) and computer-aided design/computer-aided manufacturing (CAD/CAM) have recently helped improve efficiency and accuracy in many different craniofacial surgeries. Research has mainly focused on the use in the adult population with the exception of the use for mandibular distractions and cranial vault remodeling in the pediatric population. This study aims to elucidate the role of VSP and CAD/CAM in complex pediatric craniofacial cases by exploring its use in the correction of midface hypoplasia, orbital dystopia, mandibular reconstruction, and posterior cranial vault expansion. A retrospective analysis of thirteen patients who underwent 3d, CAD/CAM- assisted preoperative surgical planning between 2012 and 2016 was performed. All CAD/CAM assisted surgical planning was done in conjunction with a third party vendor (either 3D Systems or Materialise). Cutting and positioning guides as well as models were produced based on the virtual plan. Surgeries included free fibula mandible reconstruction (n = 4), lefort I osteotomy and distraction (n = 2), lefort II osteotomy with monobloc distraction (n = 1), expansion of the posterior vault for correction of chiari malformation (n = 3), and secondary orbital and midface reconstruction for facial trauma (n = 3). The patient's age, diagnosis, previous surgeries, length of operating time, complications, and post-surgery satisfaction were determined. In all cases we found presurgical planning was helpful to improve accuracy and significantly decrease intra-operative time. In cases where distraction was used, the planned and actual vectors were found to be accurate with excellent clinical outcomes. There were no complications except for one patient who experienced a wound infection post-operatively which did not alter the ultimate reconstruction. All patients experienced high satisfaction with their outcomes and excellent subjective aesthetic results were achieved. Preoperative planning using CAD/CAM and VSP allows for safe and precise craniofacial reconstruction in complex pediatric cases with a reduction of operative time. Copyright © 2017 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Swab, A. Geoffrey
2012-01-01
This study of cooperative learning in post-secondary engineering education investigated achievement of engineering students enrolled in two intact sections of a computer-aided drafting (CAD) course. Quasi-experimental and qualitative methods were employed in comparing student achievement resulting from out-of-class cooperative and individualistic…
Computer-Aided Design in Further Education.
ERIC Educational Resources Information Center
Ingham, Peter, Ed.
This publication updates the 1982 occasional paper that was intended to foster staff awareness and assist colleges in Great Britain considering the use of computer-aided design (CAD) material in engineering courses. The paper begins by defining CAD and its place in the Integrated Business System with a brief discussion of the effect of CAD on the…
Do CAD/CAM dentures really release less monomer than conventional dentures?
Steinmassl, Patricia-Anca; Wiedemair, Verena; Huck, Christian; Klaunzer, Florian; Steinmassl, Otto; Grunert, Ingrid; Dumfahrt, Herbert
2017-06-01
Computer-aided design (CAD)/computer-aided manufacturing (CAM) dentures are assumed to have more favourable material properties than conventionally fabricated dentures, among them a lower methacrylate monomer release. The aim of this study was to test this hypothesis. CAD/CAM dentures were generated from ten different master casts by using four different CAD/CAM systems. Conventional, heat-polymerised dentures served as control group. Denture weight and volume were measured; the density was calculated, and the denture surface area was assessed digitally. The monomer release after 7 days of water storage was measured by high-performance liquid chromatography. Whole You Nexteeth and Wieland Digital Dentures had significantly lower mean volume and weight than conventional dentures. Baltic Denture System and Whole You Nexteeth had a significantly increased density. Baltic Denture System had a significantly smaller surface area. None of the CAD/CAM dentures released significantly less monomer than the control group. All tested dentures released very low amounts of methacrylate monomer, but not significantly less than conventional dentures. A statistically significant difference might nevertheless exist in comparison to other, less recommendable denture base materials, such as the frequently used autopolymerising resins. CAD/CAM denture fabrication has numerous advantages. It enables the fabrication of dentures with lower resin volume and lower denture weight. Both could increase the patient comfort. Dentures with higher density might exhibit more favourable mechanical properties. The hypothesis that CAD/CAM dentures release less monomer than conventional dentures could, however, not be verified.
A CAD system and quality assurance protocol for bone age assessment utilizing digital hand atlas
NASA Astrophysics Data System (ADS)
Gertych, Arakadiusz; Zhang, Aifeng; Ferrara, Benjamin; Liu, Brent J.
2007-03-01
Determination of bone age assessment (BAA) in pediatric radiology is a task based on detailed analysis of patient's left hand X-ray. The current standard utilized in clinical practice relies on a subjective comparison of the hand with patterns in the book atlas. The computerized approach to BAA (CBAA) utilizes automatic analysis of the regions of interest in the hand image. This procedure is followed by extraction of quantitative features sensitive to skeletal development that are further converted to a bone age value utilizing knowledge from the digital hand atlas (DHA). This also allows providing BAA results resembling current clinical approach. All developed methodologies have been combined into one CAD module with a graphical user interface (GUI). CBAA can also improve the statistical and analytical accuracy based on a clinical work-flow analysis. For this purpose a quality assurance protocol (QAP) has been developed. Implementation of the QAP helped to make the CAD more robust and find images that cannot meet conditions required by DHA standards. Moreover, the entire CAD-DHA system may gain further benefits if clinical acquisition protocol is modified. The goal of this study is to present the performance improvement of the overall CAD-DHA system with QAP and the comparison of the CAD results with chronological age of 1390 normal subjects from the DHA. The CAD workstation can process images from local image database or from a PACS server.
Computer-aided detection of breast masses: Four-view strategy for screening mammography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wei Jun; Chan Heangping; Zhou Chuan
2011-04-15
Purpose: To improve the performance of a computer-aided detection (CAD) system for mass detection by using four-view information in screening mammography. Methods: The authors developed a four-view CAD system that emulates radiologists' reading by using the craniocaudal and mediolateral oblique views of the ipsilateral breast to reduce false positives (FPs) and the corresponding views of the contralateral breast to detect asymmetry. The CAD system consists of four major components: (1) Initial detection of breast masses on individual views, (2) information fusion of the ipsilateral views of the breast (referred to as two-view analysis), (3) information fusion of the corresponding viewsmore » of the contralateral breast (referred to as bilateral analysis), and (4) fusion of the four-view information with a decision tree. The authors collected two data sets for training and testing of the CAD system: A mass set containing 389 patients with 389 biopsy-proven masses and a normal set containing 200 normal subjects. All cases had four-view mammograms. The true locations of the masses on the mammograms were identified by an experienced MQSA radiologist. The authors randomly divided the mass set into two independent sets for cross validation training and testing. The overall test performance was assessed by averaging the free response receiver operating characteristic (FROC) curves of the two test subsets. The FP rates during the FROC analysis were estimated by using the normal set only. The jackknife free-response ROC (JAFROC) method was used to estimate the statistical significance of the difference between the test FROC curves obtained with the single-view and the four-view CAD systems. Results: Using the single-view CAD system, the breast-based test sensitivities were 58% and 77% at the FP rates of 0.5 and 1.0 per image, respectively. With the four-view CAD system, the breast-based test sensitivities were improved to 76% and 87% at the corresponding FP rates, respectively. The improvement was found to be statistically significant (p<0.0001) by JAFROC analysis. Conclusions: The four-view information fusion approach that emulates radiologists' reading strategy significantly improves the performance of breast mass detection of the CAD system in comparison with the single-view approach.« less
JAMSTEC Compact Arctic Drifter (J-CAD): A new Generation drifting buoy to observe the Arctic Ocean
NASA Astrophysics Data System (ADS)
Hatakeyama, Kiyoshi; Hosono, Masuo; Shimada, Koji; Kikuchi, Takashi; Nishino, Shigeto
The Arctic Ocean is one of the most sensitive regions to the earth environment changes. Japan Marine Science and Technology Center developed a new drift buoy to observe the Arctic Ocean. The name of the buoy is J-CAD (JAMSTEC Compact Arctic Drifter). From 1991 to 1993, JAMSTEC developed Ice-Ocean Environmental Buoy (IOEB) as a buoy to observe the Arctic Ocean in cooperation with Woods Hole Oceanographic Institution. The J-CAD is the buoy, which adopted the latest technology based on the knowledge and experience of IOEB development. The J-CAD was designed and developed by JAMSTEC and made by a Canadian Company MetOcean. JAMSTEC did design and development, and a Canadian company Met-Ocean made the J-CAD. It acquires meteorological and oceanographic data of the Arctic Ocean, and transmits the data that it measured via satellite. It dose also store the data inside its memory. An Inductive Modem system, which was developed by Sea-Bird Electronics, Inc. in the United States, was adopted in the underwater transmission system that data on each ocean sensor were collected. An ORBCOMM communication system was adopted for the satellite data transmission. J-CAD-1 was installed at 89°41'N 130°20'W on April 24, 2000, and the observation was started. August 1st was the day when 100 days have passed since the J-CAD-1 was installed on the North Pole. And now, the distance J-CAD-1 has covered exceeds 400 km, and it has transmitted data more than 500 k byte. A part of the data is introduced to the public in the homepage (http://w3.jamstec.go.jp: 8338) of the Arctic research group of JAMSTEC.
NASA Technical Reports Server (NTRS)
Afjeh, Abdollah A.; Reed, John A.
2003-01-01
Mesh generation has long been recognized as a bottleneck in the CFD process. While much research on automating the volume mesh generation process have been relatively successful,these methods rely on appropriate initial surface triangulation to work properly. Surface discretization has been one of the least automated steps in computational simulation due to its dependence on implicitly defined CAD surfaces and curves. Differences in CAD peometry engines manifest themselves in discrepancies in their interpretation of the same entities. This lack of "good" geometry causes significant problems for mesh generators, requiring users to "repair" the CAD geometry before mesh generation. The problem is exacerbated when CAD geometry is translated to other forms (e.g., IGES )which do not include important topological and construction information in addition to entity geometry. One technique to avoid these problems is to access the CAD geometry directly from the mesh generating software, rather than through files. By accessing the geometry model (not a discretized version) in its native environment, t h s a proach avoids translation to a format which can deplete the model of topological information. Our approach to enable models developed in the Denali software environment to directly access CAD geometry and functions is through an Application Programming Interface (API) known as CAPRI. CAPRI provides a layer of indirection through which CAD-specific data may be accessed by an application program using CAD-system neutral C and FORTRAN language function calls. CAPRI supports a general set of CAD operations such as truth testing, geometry construction and entity queries.
Karabuva, Svjetlana; Carević, Vedran; Radić, Mislav; Fabijanić, Damir
2013-01-01
The aim of study was to: 1) examine the relationship between ABO blood groups and extent of coronary atherosclerosis in patients with chronic coronary artery disease (CAD), 2) compare ABO blood groups distribution in CAD patients and general population, 3) examine possible differences in traditional risk factors frequency in CAD patients with different ABO blood groups. In the 646 chronic CAD patients (72.4% males) coronary angiograms were scored by quantitative assessment using multiple angiographic scoring system, Traditional risk factors were self reported or measured by standard methods. ABO blood distribution of patients was compared with group of 651 healthy blood donors (74.6% males). Among all ABO blood group patients there was no significant difference between the extent of coronary atherosclerosis with regard to all the three scoring systems: number of affected coronary arteries (P = 0.857), Gensini score (P = 0.818), and number of segments narrowed > 50% (P = 0.781). There was no significant difference in ABO blood group distribution between CAD patients and healthy blood donors. Among CAD patients, men with blood group AB were significantly younger than their pairs with non-AB blood groups (P = 0.008). Among CAD patients with AB blood group, males < 50 yrs were significantly overrepresented when compared with the non-AB groups (P = 0.003). No association between ABO blood groups and the extent of coronary atherosclerosis in Croatian CAD patients is observed. Observation that AB blood group might possibly identify Croatian males at risk to develop the premature CAD has to be tested in larger cohort of patients.
Complete Dentures Fabricated with CAD/CAM Technology and a Traditional Clinical Recording Method.
Janeva, Nadica; Kovacevska, Gordana; Janev, Edvard
2017-10-15
The introduction of computer-aided design/computer-aided manufacturing (CAD/CAM) technology into complete denture (CD) fabrication ushered in a new era in removable prosthodontics. Commercially available CAD/CAM denture systems are expected to improve upon the disadvantages associated with conventional fabrication. The purpose of this report is to present the workflow involved in fabricating a CD with a traditional clinical recording method and CAD/CAM technology and to summarize the advantages to the dental practitioner and the patient.
Diagnostic performance of an acoustic-based system for coronary artery disease risk stratification.
Winther, Simon; Nissen, Louise; Schmidt, Samuel Emil; Westra, Jelmer Sybren; Rasmussen, Laust Dupont; Knudsen, Lars Lyhne; Madsen, Lene Helleskov; Kirk Johansen, Jane; Larsen, Bjarke Skogstad; Struijk, Johannes Jan; Frost, Lars; Holm, Niels Ramsing; Christiansen, Evald Høj; Botker, Hans Erik; Bøttcher, Morten
2018-06-01
Diagnosing coronary artery disease (CAD) continues to require substantial healthcare resources. Acoustic analysis of transcutaneous heart sounds of cardiac movement and intracoronary turbulence due to obstructive coronary disease could potentially change this. The aim of this study was thus to test the diagnostic accuracy of a new portable acoustic device for detection of CAD. We included 1675 patients consecutively with low to intermediate likelihood of CAD who had been referred for cardiac CT angiography. If significant obstruction was suspected in any coronary segment, patients were referred to invasive angiography and fractional flow reserve (FFR) assessment. Heart sound analysis was performed in all patients. A predefined acoustic CAD-score algorithm was evaluated; subsequently, we developed and validated an updated CAD-score algorithm that included both acoustic features and clinical risk factors. Low risk is indicated by a CAD-score value ≤20. Haemodynamically significant CAD assessed from FFR was present in 145 (10.0%) patients. In the entire cohort, the predefined CAD-score had a sensitivity of 63% and a specificity of 44%. In total, 50% had an updated CAD-score value ≤20. At this cut-off, sensitivity was 81% (95% CI 73% to 87%), specificity 53% (95% CI 50% to 56%), positive predictive value 16% (95% CI 13% to 18%) and negative predictive value 96% (95% CI 95% to 98%) for diagnosing haemodynamically significant CAD. Sound-based detection of CAD enables risk stratification superior to clinical risk scores. With a negative predictive value of 96%, this new acoustic rule-out system could potentially supplement clinical assessment to guide decisions on the need for further diagnostic investigation. ClinicalTrials.gov identifier NCT02264717; Results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Bahit, Maria Cecilia; Lopes, Renato D; Wojdyla, Daniel M; Hohnloser, Stefan H; Alexander, John H; Lewis, Basil S; Aylward, Philip E; Verheugt, Freek W A; Keltai, Matyas; Diaz, Rafael; Hanna, Michael; Granger, Christopher B; Wallentin, Lars
2013-12-10
A substantial portion of patients with atrial fibrillation (AF) also have coronary artery disease (CAD) and are at risk for coronary events. Warfarin is known to reduce these events, but increase the risk of bleeding. We assessed the effects of apixaban compared with warfarin in AF patients with and without prior CAD. In ARISTOTLE, 18,201 patients with AF were randomized to apixaban or warfarin. History of CAD was defined as documented CAD, prior myocardial infarction, and/or history of coronary revascularization. We analyzed baseline characteristics and clinical outcomes of patients with and without prior CAD and compared outcomes by randomized treatment using Cox models. A total of 6639 (36.5%) patients had prior CAD. These patients were more often male, more likely to have prior stroke, diabetes, and hypertension, and more often received aspirin at baseline (42.2% vs. 24.5%). The effects of apixaban were similar among patients with and without prior CAD on reducing stroke or systemic embolism and death from any cause (hazard ratio [HR] 0.95, 95% confidence interval [CI] 0.71-1.27, P for interaction=0.12; HR 0.96, 95% CI 0.81-1.13, P for interaction=0.28). Rates of myocardial infarction were numerically lower with apixaban than warfarin among patients with and without prior CAD. The effect of apixaban on reducing major bleeding and intracranial hemorrhage was consistent in patients with and without CAD. In patients with AF, apixaban more often prevented stroke or systemic embolism and death and caused less bleeding than warfarin, regardless of the presence of prior CAD. Given the common occurrence of AF and CAD and the higher rates of cardiovascular events and death, our results indicate that apixaban may be a better treatment option than warfarin for these high-risk patients. © 2013.
NASA Astrophysics Data System (ADS)
Mazzetti, S.; Giannini, V.; Russo, F.; Regge, D.
2018-05-01
Computer-aided diagnosis (CAD) systems are increasingly being used in clinical settings to report multi-parametric magnetic resonance imaging (mp-MRI) of the prostate. Usually, CAD systems automatically highlight cancer-suspicious regions to the radiologist, reducing reader variability and interpretation errors. Nevertheless, implementing this software requires the selection of which mp-MRI parameters can best discriminate between malignant and non-malignant regions. To exploit functional information, some parameters are derived from dynamic contrast-enhanced (DCE) acquisitions. In particular, much CAD software employs pharmacokinetic features, such as K trans and k ep, derived from the Tofts model, to estimate a likelihood map of malignancy. However, non-pharmacokinetic models can be also used to describe DCE-MRI curves, without any requirement for prior knowledge or measurement of the arterial input function, which could potentially lead to large errors in parameter estimation. In this work, we implemented an empirical function derived from the phenomenological universalities (PUN) class to fit DCE-MRI. The parameters of the PUN model are used in combination with T2-weighted and diffusion-weighted acquisitions to feed a support vector machine classifier to produce a voxel-wise malignancy likelihood map of the prostate. The results were all compared to those for a CAD system based on Tofts pharmacokinetic features to describe DCE-MRI curves, using different quality aspects of image segmentation, while also evaluating the number and size of false positive (FP) candidate regions. This study included 61 patients with 70 biopsy-proven prostate cancers (PCa). The metrics used to evaluate segmentation quality between the two CAD systems were not statistically different, although the PUN-based CAD reported a lower number of FP, with reduced size compared to the Tofts-based CAD. In conclusion, the CAD software based on PUN parameters is a feasible means with which to detect PCa, without affecting segmentation quality, and hence it could be successfully applied in clinical settings, improving the automated diagnosis process and reducing computational complexity.
Improving aircraft conceptual design - A PHIGS interactive graphics interface for ACSYNT
NASA Technical Reports Server (NTRS)
Wampler, S. G.; Myklebust, A.; Jayaram, S.; Gelhausen, P.
1988-01-01
A CAD interface has been created for the 'ACSYNT' aircraft conceptual design code that permits the execution and control of the design process via interactive graphics menus. This CAD interface was coded entirely with the new three-dimensional graphics standard, the Programmer's Hierarchical Interactive Graphics System. The CAD/ACSYNT system is designed for use by state-of-the-art high-speed imaging work stations. Attention is given to the approaches employed in modeling, data storage, and rendering.
NASA Astrophysics Data System (ADS)
Mostapha, Mahmoud; Khalifa, Fahmi; Alansary, Amir; Soliman, Ahmed; Gimel'farb, Georgy; El-Baz, Ayman
2013-10-01
Early detection of renal transplant rejection is important to implement appropriate medical and immune therapy in patients with transplanted kidneys. In literature, a large number of computer-aided diagnostic (CAD) systems using different image modalities, such as ultrasound (US), magnetic resonance imaging (MRI), computed tomography (CT), and radionuclide imaging, have been proposed for early detection of kidney diseases. A typical CAD system for kidney diagnosis consists of a set of processing steps including: motion correction, segmentation of the kidney and/or its internal structures (e.g., cortex, medulla), construction of agent kinetic curves, functional parameter estimation, diagnosis, and assessment of the kidney status. In this paper, we survey the current state-of-the-art CAD systems that have been developed for kidney disease diagnosis using dynamic MRI. In addition, the paper addresses several challenges that researchers face in developing efficient, fast and reliable CAD systems for the early detection of kidney diseases.
Computer-Aided Diagnosis in Medical Imaging: Historical Review, Current Status and Future Potential
Doi, Kunio
2007-01-01
Computer-aided diagnosis (CAD) has become one of the major research subjects in medical imaging and diagnostic radiology. In this article, the motivation and philosophy for early development of CAD schemes are presented together with the current status and future potential of CAD in a PACS environment. With CAD, radiologists use the computer output as a “second opinion” and make the final decisions. CAD is a concept established by taking into account equally the roles of physicians and computers, whereas automated computer diagnosis is a concept based on computer algorithms only. With CAD, the performance by computers does not have to be comparable to or better than that by physicians, but needs to be complementary to that by physicians. In fact, a large number of CAD systems have been employed for assisting physicians in the early detection of breast cancers on mammograms. A CAD scheme that makes use of lateral chest images has the potential to improve the overall performance in the detection of lung nodules when combined with another CAD scheme for PA chest images. Because vertebral fractures can be detected reliably by computer on lateral chest radiographs, radiologists’ accuracy in the detection of vertebral fractures would be improved by the use of CAD, and thus early diagnosis of osteoporosis would become possible. In MRA, a CAD system has been developed for assisting radiologists in the detection of intracranial aneurysms. On successive bone scan images, a CAD scheme for detection of interval changes has been developed by use of temporal subtraction images. In the future, many CAD schemes could be assembled as packages and implemented as a part of PACS. For example, the package for chest CAD may include the computerized detection of lung nodules, interstitial opacities, cardiomegaly, vertebral fractures, and interval changes in chest radiographs as well as the computerized classification of benign and malignant nodules and the differential diagnosis of interstitial lung diseases. In order to assist in the differential diagnosis, it would be possible to search for and retrieve images (or lesions) with known pathology, which would be very similar to a new unknown case, from PACS when a reliable and useful method has been developed for quantifying the similarity of a pair of images for visual comparison by radiologists. PMID:17349778
Stona, Deborah; Burnett, Luiz Henrique; Mota, Eduardo Gonçalves; Spohr, Ana Maria
2015-07-01
Because no information was found in the dental literature regarding the fracture resistance of all-ceramic crowns using CEREC (Sirona) computer-aided design and computer-aided manufacturing (CAD-CAM) system on solid abutments, the authors conducted a study. Sixty synOcta (Straumann) implant replicas and regular neck solid abutments were embedded in acrylic resin and randomly assigned (n = 20 per group). Three types of ceramics were used: feldspathic, CEREC VITABLOCS Mark II (VITA); leucite, IPS Empress CAD (Ivoclar Vivadent); and lithium disilicate, IPS e.max CAD (Ivoclar Vivadent). The crowns were fabricated by the CEREC CAD-CAM system. After receiving glaze, the crowns were cemented with RelyX U200 (3M ESPE) resin cement under load of 1 kilogram. For each ceramic, one-half of the specimens were subjected to the fracture resistance testing in a universal testing machine with a crosshead speed of 1 millimeter per minute, and the other half were subjected to the fractured resistance testing after 1,000,000 cyclic fatigue loading at 100 newtons. According to a 2-way analysis of variance, the interaction between the material and mechanical cycling was significant (P = .0001). According to a Tukey test (α = .05), the fracture resistance findings with or without cyclic fatigue loading were as follows, respectively: CEREC VITABLOCKS Mark II (405 N/454 N) was statistically lower than IPS Empress CAD (1169 N/1240 N) and IPS e.max CAD (1378 N/1025 N) (P < .05). The IPS Empress CAD and IPS e.max CAD did not differ statistically (P > .05). According to a t test, there was no statistical difference in the fracture resistance with and without cyclic fatigue loading for CEREC VITABLOCS Mark II and IPS Empress CAD (P > .05). For IPS e.max CAD, the fracture resistance without cyclic fatigue loading was statistically superior to that obtained with cyclic fatigue loading (P < .05). The IPS Empress CAD and IPS e.max CAD showed higher fracture resistance compared with CEREC VITABLOCS Mark II. The cyclic fatigue loading negatively influenced only IPS e.max CAD. The CEREC VITABLOCS Mark II, IPS Empress CAD, and IPS e.max CAD ceramic crowns cemented on solid abutments showed sufficient resistance to withstand normal chewing forces. Copyright © 2015 American Dental Association. Published by Elsevier Inc. All rights reserved.
BioNetCAD: design, simulation and experimental validation of synthetic biochemical networks
Rialle, Stéphanie; Felicori, Liza; Dias-Lopes, Camila; Pérès, Sabine; El Atia, Sanaâ; Thierry, Alain R.; Amar, Patrick; Molina, Franck
2010-01-01
Motivation: Synthetic biology studies how to design and construct biological systems with functions that do not exist in nature. Biochemical networks, although easier to control, have been used less frequently than genetic networks as a base to build a synthetic system. To date, no clear engineering principles exist to design such cell-free biochemical networks. Results: We describe a methodology for the construction of synthetic biochemical networks based on three main steps: design, simulation and experimental validation. We developed BioNetCAD to help users to go through these steps. BioNetCAD allows designing abstract networks that can be implemented thanks to CompuBioTicDB, a database of parts for synthetic biology. BioNetCAD enables also simulations with the HSim software and the classical Ordinary Differential Equations (ODE). We demonstrate with a case study that BioNetCAD can rationalize and reduce further experimental validation during the construction of a biochemical network. Availability and implementation: BioNetCAD is freely available at http://www.sysdiag.cnrs.fr/BioNetCAD. It is implemented in Java and supported on MS Windows. CompuBioTicDB is freely accessible at http://compubiotic.sysdiag.cnrs.fr/ Contact: stephanie.rialle@sysdiag.cnrs.fr; franck.molina@sysdiag.cnrs.fr Supplementary information: Supplementary data are available at Bioinformatics online. PMID:20628073
Research on AutoCAD secondary development and function expansion based on VBA technology
NASA Astrophysics Data System (ADS)
Zhang, Runmei; Gu, Yehuan
2017-06-01
AutoCAD is the most widely used drawing tool among the similar design drawing products. In the process of drawing different types of design drawings of the same product, there are a lot of repetitive and single work contents. The traditional manual method uses a drawing software AutoCAD drawing graphics with low efficiency, high error rate and high input cost shortcomings and many more. In order to solve these problems, the design of the parametric drawing system of the hot-rolled I-beam (steel beam) cross-section is completed by using the VBA secondary development tool and the Access database software with large-capacity storage data, and the analysis of the functional extension of the plane drawing and the parametric drawing design in this paper. For the secondary development of AutoCAD functions, the system drawing work will be simplified and work efficiency also has been greatly improved. This introduction of parametric design of AutoCAD drawing system to promote the industrial mass production and related industries economic growth rate similar to the standard I-beam hot-rolled products.
Experimental CAD Course Uses Low-Cost Systems.
ERIC Educational Resources Information Center
Wohlers, Terry
1984-01-01
Describes the outstanding results obtained when a department of industrial sciences used special software on microcomputers to teach computer-aided design (CAD) as an alternative to much more expensive equipment. The systems used and prospects for the future are also considered. (JN)
Systemic inflammation is higher in peripheral artery disease than in stable coronary artery disease.
Rein, Philipp; Saely, Christoph H; Silbernagel, Günther; Vonbank, Alexander; Mathies, Rainer; Drexel, Heinz; Baumgartner, Iris
2015-04-01
The knowledge on the level of systemic inflammation in peripheral artery disease (PAD) is less well established than that in coronary artery disease (CAD). Systemic inflammation frequently coincides with atherosclerosis, but also with various traits of the metabolic syndrome (MetS). The individual contribution of CAD, PAD, and the MetS to inflammation is not known. We enrolled a total of 1396 patients, 460 patients with PAD Fontaine stages IIa-IV verified by duplex ultrasound (PAD group) and 936 patients free of limb claudication undergoing coronary angiography, of whom 507 had significant CAD with coronary stenoses ≥50% (CAD group), and 429 did not have significant CAD at angiography (control group). C-reactive protein (CRP) was significantly higher in the PAD than in the CAD or in the control group (0.86 ± 1.85 mg/dl versus 0.44 ± 0.87 mg/dl and 0.39 ± 0.52 mg/dl, respectively, p < 0.001 for both comparisons). These significant differences were confirmed when patients with and subjects without the MetS were analyzed separately. In particular, within the PAD group, CRP was significantly higher in patients with the MetS than in subjects without the MetS (1.04 ± 2.01 vs. 0.67 ± 1.64 mg/dl; p = 0.001) and both, the presence of PAD and the MetS proved to be independently associated with CRP in analysis of covariance (F = 31.84; p < 0.001 and F = 10.52; p = 0.001, respectively). Inflammatory activity in PAD patients is higher than in CAD patients and is particularly high in PAD patients affected by the MetS. Low grade systemic inflammation is independently associated with both the MetS and PAD. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Effectiveness of computer aided detection for solitary pulmonary nodules
NASA Astrophysics Data System (ADS)
Yan, Jiayong; Li, Wenjie; Du, Xiangying; Lu, Huihai; Xu, Jianrong; Xu, Mantao; Rong, Dongdong
2009-02-01
This study is to investigate the incremental effect of using a high performance computer-aided detection (CAD) system in detection of solitary pulmonary nodules in chest radiographs. The Kodak Chest CAD system was evaluated by a panel of six radiologists at different levels of experience. The observer study consisted of two independent phases: readings without CAD and readings with assistance of CAD. The study was conducted over a set of chest radiographs comprising 150 cancer cases and 150 cancer-free cases. The actual sensitivity of the CAD system is 72% with 3.7 false positives per case. Receiver operating characteristic (ROC) analysis was used to assess the overall observer performance. The AUZ (area under ROC curve) showed a significantly improvement (P=0.0001) from 0.844 to 0.884 after using CAD. The ROC analysis was also applied for observer performances on nodules in different sizes and visibilities. The average AUZs are improved from 0.798 to 0.835 (P=0.0003) for 5-10mm nodules, 0.853 to 0.907 (P=0.001) for 10-15mm nodules, 0.864 to 0.897 (P=0.051) for 15-20 mm nodules and 0.859 to 0.896 (P=0.0342) for 20-30mm nodules, respectively. For different visibilities, the average AUZs are improved from 0.886 to 0.915 (P=0.0337), 0.803 to 0.840 (P=0.063), 0.830 to 0.893 (P=0.0001), and 0.813 to 0.847 (P=0.152), for nodules clearly visible, hidden by ribs, partially overlap with ribs, and overlap with other structures, respectively. These results showed that observer performance could be greatly improved when the CAD system is employed as a second reader, especially for small nodules and nodules occluded by ribs.
Goeree, Ron; Chiva-Razavi, Sima; Gunda, Praveen; Graham, Christopher N; Miles, LaStella; Nikoglou, Efthalia; Jugl, Steffen M; Gladman, Dafna D
2018-02-01
The study evaluates the cost-effectiveness of secukinumab, a fully human monoclonal antibody that selectively neutralizes interleukin (IL)-17A, vs currently licensed biologic treatments in patients with active psoriatic arthritis (PsA) from a Canadian healthcare system perspective. A decision analytic semi-Markov model evaluated the cost-effectiveness of secukinumab 150 mg and 300 mg compared to subcutaneous biologics adalimumab, certolizumab pegol, etanercept, golimumab, and ustekinumab, and intravenous biologics infliximab and infliximab biosimilar in biologic-naive and biologic-experienced patients over a lifetime horizon. The response to treatments was evaluated after 12 weeks by PsA Response Criteria (PsARC) response rates. Non-responders or patients discontinuing initial-line of biologic treatment were allowed to switch to subsequent-line biologics. Model input parameters (Psoriasis Area Severity Index [PASI], Health Assessment Questionnaire [HAQ], withdrawal rates, costs, and resource use) were collected from clinical trials, published literature, and other Canadian sources. Benefits were expressed as quality-adjusted life years (QALYs). An annual discount rate of 5% was applied to costs and benefits. The robustness of the study findings were evaluated via sensitivity analyses. Biologic-naive patients treated with secukinumab achieved the highest number of QALYs (8.54) at the lowest cost (CAD 925,387) over a lifetime horizon vs all comparators. Secukinumab dominated all treatments, except for infliximab and its biosimilar, which achieved minimally more QALYs (8.58). However, infliximab and its biosimilar incurred more costs than secukinumab (infliximab: CAD 1,015,437; infliximab biosimilar: CAD 941,004), resulting in higher cost-effectiveness estimates relative to secukinumab. In the biologic-experienced population, secukinumab dominated all treatments as it generated more QALYs (8.89) at lower costs (CAD 954,692). Deterministic sensitivity analyses indicated the results were most sensitive to variation in PsARC response rates, change in HAQ, and utility values in both populations. Secukinumab is either dominant or cost-effective vs all licensed biologics for the treatment of active PsA in biologic-naive and biologic-experienced populations in Canada.
On the Use of Parmetric-CAD Systems and Cartesian Methods for Aerodynamic Design
NASA Technical Reports Server (NTRS)
Nemec, Marian; Aftosmis, Michael J.; Pulliam, Thomas H.
2004-01-01
Automated, high-fidelity tools for aerodynamic design face critical issues in attempting to optimize real-life geometry arid in permitting radical design changes. Success in these areas promises not only significantly shorter design- cycle times, but also superior and unconventional designs. To address these issues, we investigate the use of a parmetric-CAD system in conjunction with an embedded-boundary Cartesian method. Our goal is to combine the modeling capabilities of feature-based CAD with the robustness and flexibility of component-based Cartesian volume-mesh generation for complex geometry problems. We present the development of an automated optimization frame-work with a focus on the deployment of such a CAD-based design approach in a heterogeneous parallel computing environment.
Rendenbach, Carsten; Sellenschloh, Kay; Gerbig, Lucca; Morlock, Michael M; Beck-Broichsitter, Benedicta; Smeets, Ralf; Heiland, Max; Huber, Gerd; Hanken, Henning
2017-11-01
CAD/CAM reconstruction plates have become a viable option for mandible reconstruction. The aim of this study was to determine whether CAD/CAM plates provide higher fatigue strength compared with conventional fixation systems. 1.0 mm miniplates, 2.0 mm conventional locking plates (DePuy Synthes, Umkirch, Germany), and 2.0 mm CAD/CAM plates (Materialise, Leuven, Belgium/DePuy Synthes) were used to reconstruct a polyurethane mandible model (Synbone, Malans, CH) with cortical and cancellous bone equivalents. Mastication was simulated via cyclic dynamic testing using a universal testing machine (MTS, Bionix, Eden Prairie, MN, USA) until material failure reached a rate of 1 Hz with increasing loads on the left side. No significant difference was found between the groups until a load of 300 N. At higher loads, vertical displacement differed increasingly, with a poorer performance of miniplates (p = 0.04). Plate breakage occurred in miniplates and conventional locking plates. Screw breakage was recorded as the primary failure mechanism in CAD/CAM plates. Stiffness was significantly higher with the CAD/CAM plates (p = 0.04). CAD/CAM plates and reconstruction plates provide higher fatigue strength than miniplates, and stiffness is highest in CAD/CAM systems. All tested fixation methods seem sufficiently stable for mandible reconstruction. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Cury, Ricardo C; Abbara, Suhny; Achenbach, Stephan; Agatston, Arthur; Berman, Daniel S; Budoff, Matthew J; Dill, Karin E; Jacobs, Jill E; Maroules, Christopher D; Rubin, Geoffrey D; Rybicki, Frank J; Schoepf, U Joseph; Shaw, Leslee J; Stillman, Arthur E; White, Charles S; Woodard, Pamela K; Leipsic, Jonathon A
2016-12-01
The intent of CAD-RADS - Coronary Artery Disease Reporting and Data System is to create a standardized method to communicate findings of coronary CT angiography (coronary CTA) in order to facilitate decision-making regarding further patient management. The suggested CAD-RADS classification is applied on a per-patient basis and represents the highest-grade coronary artery lesion documented by coronary CTA. It ranges from CAD-RADS 0 (Zero) for the complete absence of stenosis and plaque to CAD-RADS 5 for the presence of at least one totally occluded coronary artery and should always be interpreted in conjunction with the impression found in the report. Specific recommendations are provided for further management of patients with stable or acute chest pain based on the CAD-RADS classification. The main goal of CAD-RADS is to standardize reporting of coronary CTA results and to facilitate communication of test results to referring physicians along with suggestions for subsequent patient management. In addition, CAD-RADS will provide a framework of standardization that may benefit education, research, peer-review and quality assurance with the potential to ultimately result in improved quality of care. Copyright © 2016 Society of Cardiovascular Computed Tomography and the American College of Radiology. Published by Elsevier Inc. All rights reserved.
Al-Meraikhi, Hadi; Yilmaz, Burak; McGlumphy, Edwin; Brantley, William A; Johnston, William M
2018-01-01
Computer-aided design and computer-aided manufacturing (CAD-CAM)-fabricated titanium and zirconia implant-supported fixed dental prostheses have become increasingly popular for restoring patients with complete edentulism. However, the distortion level of these frameworks is not well known. The purpose of this in vitro study was to compare the 3-dimensional (3D) distortion of CAD-CAM zirconia and titanium implant-fixed screw-retained complete dental prostheses. A master edentulous model with 4 implants at the positions of the maxillary first molars and canines was used. Multiunit abutments (Nobel Biocare) secured to the model were digitally scanned using scan bodies and a laboratory scanner (S600 ARTI; Zirkonzahn). Titanium (n=5) and zirconia (n=5) frameworks were milled using a CAD-CAM system (Zirkonzahn M1; Zirkonzahn). All frameworks were scanned using an industrial computed tomography (CT) scanner (Nikon/X-Tek XT H 225kV MCT Micro-Focus). The direct CT scans were reconstructed to generate standard tessellation language (STL) files. To calculate the 3D distortion of the frameworks, STL files of the CT scans were aligned to the CAD model using a sum of the least squares best-fit algorithm. Surface comparison points were placed on the CAD model on the midfacial aspect of all teeth. The 3D distortion of each direct scan to the CAD model was calculated. In addition, color maps of the scan-to-CAD comparison were constructed using a ±0.500 mm color scale range. Both materials exhibited distortion; however, no significant difference was found in the amount of distortion from the CAD model between the materials (P=.747). Absolute values of deviations from the CAD model were evident in the x and y plane and less so in the z direction. Zirconia and titanium frameworks showed similar 3D distortion compared with the CAD model for the tested CAD-CAM and implant systems. The distortion was more pronounced in the horizontal and sagittal plane than in the vertical plane. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Comparative fracture strength analysis of Lava and Digident CAD/CAM zirconia ceramic crowns.
Kwon, Taek-Ka; Pak, Hyun-Soon; Yang, Jae-Ho; Han, Jung-Suk; Lee, Jai-Bong; Kim, Sung-Hun; Yeo, In-Sung
2013-05-01
All-ceramic crowns are subject to fracture during function. To minimize this common clinical complication, zirconium oxide has been used as the framework for all-ceramic crowns. The aim of this study was to compare the fracture strengths of two computer-aided design/computer-aided manufacturing (CAD/CAM) zirconia crown systems: Lava and Digident. Twenty Lava CAD/CAM zirconia crowns and twenty Digident CAD/CAM zirconia crowns were fabricated. A metal die was also duplicated from the original prepared tooth for fracture testing. A universal testing machine was used to determine the fracture strength of the crowns. THE MEAN FRACTURE STRENGTHS WERE AS FOLLOWS: 54.9 ± 15.6 N for the Lava CAD/CAM zirconia crowns and 87.0 ± 16.0 N for the Digident CAD/CAM zirconia crowns. The difference between the mean fracture strengths of the Lava and Digident crowns was statistically significant (P<.001). Lava CAD/CAM zirconia crowns showed a complete fracture of both the veneering porcelain and the core whereas the Digident CAD/CAM zirconia crowns showed fracture only of the veneering porcelain. The fracture strengths of CAD/CAM zirconia crowns differ depending on the compatibility of the core material and the veneering porcelain.
Reymus, Marcel; Roos, Malgorzata; Eichberger, Marlis; Edelhoff, Daniel; Hickel, Reinhard; Stawarczyk, Bogna
2018-04-27
Because of their industrially standardized process of manufacturing, CAD/CAM resin composites show a high degree of conversion, making a reliable bond difficult to achieve. The purpose of this experiment was to investigate the tensile bond strength (TBS) of luting composite to CAD/CAM resin composite materials as influenced by air abrasion and pretreatment strategies. The treatment factors of the present study were (1) brand of the CAD/CAM resin composite (Brilliant Crios [Coltene/Whaledent], Cerasmart [GC Europe], Shofu Block HC [Shofu], and Lava Ultimate [3M]); (2) air abrasion vs. no air abrasion; and (3) pretreatment using a silane primer (Clearfil Ceramic Primer, Kuraray) vs. a resin primer (One Coat 7 Universal, Coltene/Whaledent). Subsequently, luting composite (DuoCem, Coltene/Whaledent) was polymerized onto the substrate surface using a mold. For each combination of the levels of the three treatment factors (4 (materials) × 2 (air abrasion vs. no air abrasion; resin) × 2 (primer vs. silane primer)), n = 15, specimens were prepared. After 24 h of water storage at 37 °C and 5000 thermo-cycles (5/55 °C), TBS was measured and failure types were examined. The resulting data was analyzed using Kaplan-Meier estimates of the cumulative failure distribution function with Breslow-Gehan tests and non-parametric ANOVA (Kruskal-Wallis test) followed by the multiple pairwise Mann-Whitney U test with α-error adjustment using the Benjamini-Hochberg procedure and chi-square test (p < 0.05). The additional air abrasion step increased TBS values and lowered failure rates. Specimens pretreated using a resin primer showed significantly higher TBS and lower failure rates than those pretreated using a silane primer. The highest failure rates were observed for groups pretreated with a silane primer. Within the Shofu Block HC group, all specimens without air abrasion and pretreatment with a silane primer debonded during the aging procedure. Before fixation of CAD/CAM resin composites, the restorations should be air abraded and pretreated using a resin primer containing methyl-methacrylate to successfully bond to the luting composite. The pretreatment of the CAD/CAM resin composite using merely a silane primer results in deficient adhesion. For a reliable bond of CAD/CAM resin composites to the luting composite, air abrasion and a special pretreatment strategy are necessary in order to achieve promising long-term results.
NASA Astrophysics Data System (ADS)
Ma, Kevin C.; Zhang, Aifeng; Moin, Paymann; Fleshman, Mariam; Vachon, Linda; Liu, Brent; Huang, H. K.
2009-02-01
Bone age assessment is a radiological procedure to evaluate a child's bone age based on his or her left-hand x-ray image. The current standard is to match patient's hand with Greulich & Pyle hand atlas, which is outdated by 50 years and only uses subjects from one region and one ethnicity. To improve bone age assessment accuracy for today's children, an automated race- and gender-specific bone age assessment (BAA) system has been developed in IPILab. 1390 normal left-hand x-ray images have been collected at Children's Hospital of Los Angeles (CHLA) to form the digital hand atlas (DHA). DHA includes both male and female children of ages one to eighteen and of four ethnic groups: African American, Asian American, Caucasian, and Hispanic. In order to apply DHA and BAA CAD into a clinical environment, a web-based BAA CAD system and graphical user interface (GUI) has been implemented in Women and Children's Hospital at Los Angeles County (WCH-LAC). A CAD server has been integrated in WCH's PACS environment, and a clinical validation workflow has been designed for radiologists, who compare CAD readings with G&P readings and determine which reading is more suited for a certain case. Readings are logged in database and analyzed to assess BAA CAD performance in a clinical setting. The result is a successful installation of web-based BAA CAD system in a clinical setting.
Buchner, Sophie; Schlundt, Andreas; Lassak, Jürgen; Sattler, Michael; Jung, Kirsten
2015-07-31
The pH-responsive one-component signaling system CadC in Escherichia coli belongs to the family of ToxR-like proteins, whose members share a conserved modular structure, with an N-terminal cytoplasmic winged helix-turn-helix DNA-binding domain being followed by a single transmembrane helix and a C-terminal periplasmic pH-sensing domain. In E. coli CadC, a cytoplasmic linker comprising approximately 50 amino acids is essential for transmission of the signal from the sensor to the DNA-binding domain. However, the mechanism of transduction is poorly understood. Using NMR spectroscopy, we demonstrate here that the linker region is intrinsically disordered in solution. Furthermore, mutational analyses showed that it tolerates a range of amino acid substitutions (altering polarity, rigidity and α-helix-forming propensity), is robust to extension but is sensitive to truncation. Indeed, truncations either reversed the expression profile of the target operon cadBA or decoupled expression from external pH altogether. CadC dimerizes via its periplasmic domain, but light-scattering analysis provided no evidence for dimerization of the isolated DNA-binding domain, with or without the linker region. However, bacterial two-hybrid analysis revealed that CadC forms stable dimers in a stimulus- and linker-dependent manner, interacting only at pH<6.8. Strikingly, a variant with inversed cadBA expression profile, which lacks most of the linker, dimerizes preferentially at higher pH. Thus, we propose that the disordered CadC linker is required for transducing the pH-dependent response of the periplasmic sensor into a structural rearrangement that facilitates dimerization of the cytoplasmic CadC DNA-binding domain. Copyright © 2015 Elsevier Ltd. All rights reserved.
Elsaka, Shaymaa E
2014-12-01
To evaluate the effect of different surface treatments on the microtensile bond strength (μTBS) of novel CAD/CAM restorative materials to self-adhesive resin cement. Two types of CAD/CAM restorative materials (Vita Enamic [VE] and Lava Ultimate [LU]) were used. The specimens were divided into five groups in each test according to the surface treatment performed; Gr 1 (control; no treatment), Gr 2 (sandblasted [SB]), Gr 3 (SB+silane [S]), Gr 4 (hydrofluoric acid [HF]), and Gr 5 (HF+S). A dual-curing self-adhesive resin cement (Bifix SE [BF]) was applied to each group for testing the adhesion after 24 h of storage in distilled water or after 30 days using the μTBS test. Following fracture testing, specimens were examined with a stereomicroscope and SEM. Surface roughness and morphology of the CAD/CAM restorative materials were characterized after treatment. Data were analyzed using ANOVA and Tukey's test. The surface treatment, type of CAD/CAM restorative material, and water storage periods showed a significant effect on the μTBS (p<0.001). For the LU/BF system, there was no significant difference in the bond strength values between different surface treatments (p>0.05). On the other hand, for the VE/BF system, surface treatment with HF+S showed higher bond strength values compared with SB and HF surface treatments (p<0.05). Surface roughness and SEM analyses showed that the surface topography of CAD/CAM restorative materials was modified after treatments. The effect of surface treatments on the bond strength of novel CAD/CAM restorative materials to resin cement is material dependent. The VE/BF CAD/CAM material provided higher bond strength values compared with the LU/BF CAD/CAM material.
NASA Technical Reports Server (NTRS)
Benyo, Theresa L.
2002-01-01
Integration of a supersonic inlet simulation with a computer aided design (CAD) system is demonstrated. The integration is performed using the Project Integration Architecture (PIA). PIA provides a common environment for wrapping many types of applications. Accessing geometry data from CAD files is accomplished by incorporating appropriate function calls from the Computational Analysis Programming Interface (CAPRI). CAPRI is a CAD vendor neutral programming interface that aids in acquiring geometry data directly from CAD files. The benefits of wrapping a supersonic inlet simulation into PIA using CAPRI are; direct access of geometry data, accurate capture of geometry data, automatic conversion of data units, CAD vendor neutral operation, and on-line interactive history capture. This paper describes the PIA and the CAPRI wrapper and details the supersonic inlet simulation demonstration.
Wind Turbine Blade Design System - Aerodynamic and Structural Analysis
NASA Astrophysics Data System (ADS)
Dey, Soumitr
2011-12-01
The ever increasing need for energy and the depletion of non-renewable energy resources has led to more advancement in the "Green Energy" field, including wind energy. An improvement in performance of a Wind Turbine will enhance its economic viability, which can be achieved by better aerodynamic designs. In the present study, a design system that has been under development for gas turbine turbomachinery has been modified for designing wind turbine blades. This is a very different approach for wind turbine blade design, but will allow it to benefit from the features inherent in the geometry flexibility and broad design space of the presented system. It starts with key overall design parameters and a low-fidelity model that is used to create the initial geometry parameters. The low-fidelity system includes the axisymmetric solver with loss models, T-Axi (Turbomachinery-AXIsymmetric), MISES blade-to-blade solver and 2D wing analysis code XFLR5. The geometry parameters are used to define sections along the span of the blade and connected to the CAD model of the wind turbine blade through CAPRI (Computational Analysis PRogramming Interface), a CAD neutral API that facilitates the use of parametric geometry definition with CAD. Either the sections or the CAD geometry is then available for CFD and Finite Element Analysis. The GE 1.5sle MW wind turbine and NERL NASA Phase VI wind turbine have been used as test cases. Details of the design system application are described, and the resulting wind turbine geometry and conditions are compared to the published results of the GE and NREL wind turbines. A 2D wing analysis code XFLR5, is used for to compare results from 2D analysis to blade-to-blade analysis and the 3D CFD analysis. This kind of comparison concludes that, from hub to 25% of the span blade to blade effects or the cascade effect has to be considered, from 25% to 75%, the blade acts as a 2d wing and from 75% to the tip 3D and tip effects have to be taken into account for design considerations. In addition, the benefits of this approach for wind turbine design and future efforts are discussed.
Incorporation of CAD/CAM Restoration Into Navy Dentistry
2017-09-26
CAD/CAM Computer-aided design /Computer-assisted manufacturing CDT Common Dental Terminology DENCAS Dental Common Access System DTF Dental...to reduce avoidable dental emergencies for deployed sailors and marines. Dental Computer-aided design /Computer-assisted manufacturing (CAD/CAM...report will review and evaluate the placement rate by Navy dentists of digitally fabricated in-office ceramic restorations compared to traditional direct
Nonobstructive coronary artery disease and risk of myocardial infarction.
Maddox, Thomas M; Stanislawski, Maggie A; Grunwald, Gary K; Bradley, Steven M; Ho, P Michael; Tsai, Thomas T; Patel, Manesh R; Sandhu, Amneet; Valle, Javier; Magid, David J; Leon, Benjamin; Bhatt, Deepak L; Fihn, Stephan D; Rumsfeld, John S
2014-11-05
Little is known about cardiac adverse events among patients with nonobstructive coronary artery disease (CAD). To compare myocardial infarction (MI) and mortality rates between patients with nonobstructive CAD, obstructive CAD, and no apparent CAD in a national cohort. Retrospective cohort study of all US veterans undergoing elective coronary angiography for CAD between October 2007 and September 2012 in the Veterans Affairs health care system. Patients with prior CAD events were excluded. Angiographic CAD extent, defined by degree (no apparent CAD: no stenosis >20%; nonobstructive CAD: ≥1 stenosis ≥20% but no stenosis ≥70%; obstructive CAD: any stenosis ≥70% or left main [LM] stenosis ≥50%) and distribution (1, 2, or 3 vessel). The primary outcome was 1-year hospitalization for nonfatal MI after the index angiography. Secondary outcomes included 1-year all-cause mortality and combined 1-year MI and mortality. Among 37,674 patients, 8384 patients (22.3%) had nonobstructive CAD and 20,899 patients (55.4%) had obstructive CAD. Within 1 year, 845 patients died and 385 were rehospitalized for MI. Among patients with no apparent CAD, the 1-year MI rate was 0.11% (n = 8, 95% CI, 0.10%-0.20%) and increased progressively by 1-vessel nonobstructive CAD, 0.24% (n = 10, 95% CI, 0.10%-0.40%); 2-vessel nonobstructive CAD, 0.56% (n = 13, 95% CI, 0.30%-1.00%); 3-vessel nonobstructive CAD, 0.59% (n = 6, 95% CI, 0.30%-1.30%); 1-vessel obstructive CAD, 1.18% (n = 101, 95% CI, 1.00%-1.40%); 2-vessel obstructive CAD, 2.18% (n = 110, 95% CI, 1.80%-2.60%); and 3-vessel or LM obstructive CAD, 2.47% (n = 137, 95% CI, 2.10%-2.90%). After adjustment, 1-year MI rates increased with increasing CAD extent. Relative to patients with no apparent CAD, patients with 1-vessel nonobstructive CAD had a hazard ratio (HR) for 1-year MI of 2.0 (95% CI, 0.8-5.1); 2-vessel nonobstructive HR, 4.6 (95% CI, 2.0-10.5); 3-vessel nonobstructive HR, 4.5 (95% CI, 1.6-12.5); 1-vessel obstructive HR, 9.0 (95% CI, 4.2-19.0); 2-vessel obstructive HR, 16.5 (95% CI, 8.1-33.7); and 3-vessel or LM obstructive HR, 19.5 (95% CI, 9.9-38.2). One-year mortality rates were associated with increasing CAD extent, ranging from 1.38% among patients without apparent CAD to 4.30% with 3-vessel or LM obstructive CAD. After risk adjustment, there was no significant association between 1- or 2-vessel nonobstructive CAD and mortality, but there were significant associations with mortality for 3-vessel nonobstructive CAD (HR, 1.6; 95% CI, 1.1-2.5), 1-vessel obstructive CAD (HR, 1.9; 95% CI, 1.4-2.6), 2-vessel obstructive CAD (HR, 2.8; 95% CI, 2.1-3.7), and 3-vessel or LM obstructive CAD (HR, 3.4; 95% CI, 2.6-4.4). Similar associations were noted with the combined outcome. In this cohort of patients undergoing elective coronary angiography, nonobstructive CAD, compared with no apparent CAD, was associated with a significantly greater 1-year risk of MI and all-cause mortality. These findings suggest clinical importance of nonobstructive CAD and warrant further investigation of interventions to improve outcomes among these patients.
Design of Complete Dentures by Adopting CAD Developed for Fixed Prostheses.
Li, Yanfeng; Han, Weili; Cao, Jing; Iv, Yuan; Zhang, Yue; Han, Yishi; Shen, Yi; Ma, Zheng; Liu, Huanyue
2018-02-01
The demand for complete dentures is expected to increase worldwide, but complete dentures are mainly designed and fabricated manually involving a broad series of clinical and laboratory procedures. Therefore, the quality of complete dentures largely depends on the skills of the dentist and technician, leading to difficulty in quality control. Computer-aided design and manufacturing (CAD/CAM) has been used to design and fabricate various dental restorations including dental inlays, veneers, crowns, partial crowns, and fixed partial dentures (FPDs). It has been envisioned that the application of CAD/CAM technology could reduce intensive clinical/laboratory work for the fabrication of complete dentures; however, CAD/CAM is seldom used to fabricate complete dentures due to the lack of suitable CAD software to design virtual complete dentures although the CAM techniques are in a much advanced stage. Here we report the successful design of virtual complete dentures using CAD software of 3Shape Dental System 2012, which was developed for designing fixed prostheses instead of complete dentures. Our results demonstrated that complete dentures could be successfully designed by the combination of two modeling processes, single coping and full anatomical FPD, available in the 3Shape Dental System 2012. © 2016 by the American College of Prosthodontists.
1991-03-21
sectional representation of the spatial figure can be correctly determined. 6 The AutoLisp language system in the AutoCAD software provides the most...softwares are developed on the 32-bit machines and little progress has been reported for the 16-bit machines. Even the AutoCAD is a two-ard-a-half... AutoCAD software as the basis, developed the design package of 3-D cartridge valve blocks on IM PC/AT. To realize the 3-D displaying of cartridge valves
Schultheis, Stefan; Strub, Joerg R; Gerds, Thomas A; Guess, Petra C
2013-06-01
The authors analyzed the effect of fatigue on the survival rate and fracture load of monolithic and bi-layer CAD/CAM lithium-disilicate posterior three-unit fixed dental prostheses (FDPs) in comparison to the metal-ceramic gold standard. The authors divided 96 human premolars and molars into three equal groups. Lithium-disilicate ceramic (IPS-e.max-CAD) was milled with the CEREC-3-system in full-anatomic FDP dimensions (monolithic: M-LiCAD) or as framework (Bi-layer: BL-LiCAD) with subsequent hand-layer veneering. Metal-ceramic FDPs (MC) served as control. Single-load-to-failure tests were performed before and after mouth-motion fatigue. No fracture failures occurred during fatigue. Median fracture loads in [N], before and after fatigue were, respectively, as follows: M-LiCAD, 1,298/1,900; BL-LiCAD, 817/699; MC, 1,966/1,818. M-LiCAD and MC FPDs revealed comparable fracture loads and were both significantly higher than BL-LiCAD. M-LiCAD and BL-LiCAD both failed from core/veneer bulk fracture within the connector area. MC failures were limited to ceramic veneer fractures exposing the metal core. Fatigue had no significant effect on any group. Posterior monolithic CAD/CAM fabricated lithium-disilicate FPDs were shown to be fracture resistant with failure load results comparable to the metal-ceramic gold standard. Clinical investigations are needed to confirm these promising laboratory results. Monolithic CAD/CAM fabricated lithium-disilicate FDPs appeared to be a reliable treatment alternative for the posterior load-bearing area, whereas FDPs in bi-layer configuration were susceptible to low load fracture failure.
Front panel engineering with CAD simulation tool
NASA Astrophysics Data System (ADS)
Delacour, Jacques; Ungar, Serge; Mathieu, Gilles; Hasna, Guenther; Martinez, Pascal; Roche, Jean-Christophe
1999-04-01
THe progress made recently in display technology covers many fields of application. The specification of radiance, colorimetry and lighting efficiency creates some new challenges for designers. Photometric design is limited by the capability of correctly predicting the result of a lighting system, to save on the costs and time taken to build multiple prototypes or bread board benches. The second step of the research carried out by company OPTIS is to propose an optimization method to be applied to the lighting system, developed in the software SPEOS. The main features of the tool requires include the CAD interface, to enable fast and efficient transfer between mechanical and light design software, the source modeling, the light transfer model and an optimization tool. The CAD interface is mainly a prototype of transfer, which is not the subjects here. Photometric simulation is efficiently achieved by using the measured source encoding and a simulation by the Monte Carlo method. Today, the advantages and the limitations of the Monte Carlo method are well known. The noise reduction requires a long calculation time, which increases with the complexity of the display panel. A successful optimization is difficult to achieve, due to the long calculation time required for each optimization pass including a Monte Carlo simulation. The problem was initially defined as an engineering method of study. The experience shows that good understanding and mastering of the phenomenon of light transfer is limited by the complexity of non sequential propagation. The engineer must call for the help of a simulation and optimization tool. The main point needed to be able to perform an efficient optimization is a quick method for simulating light transfer. Much work has been done in this area and some interesting results can be observed. It must be said that the Monte Carlo method wastes time calculating some results and information which are not required for the needs of the simulation. Low efficiency transfer system cost a lot of lost time. More generally, the light transfer simulation can be treated efficiently when the integrated result is composed of elementary sub results that include quick analytical calculated intersections. The first axis of research appear. The quick integration research and the quick calculation of geometric intersections. The first axis of research brings some general solutions also valid for multi-reflection systems. The second axis requires some deep thinking on the intersection calculation. An interesting way is the subdivision of space in VOXELS. This is an adapted method of 3D division of space according to the objects and their location. An experimental software has been developed to provide a validation of the method. The gain is particularly high in complex systems. An important reduction in the calculation time has been achieved.
Prakashini, K; Babu, Satish; Rajgopal, K V; Kokila, K Raja
2016-01-01
To determine the overall performance of an existing CAD algorithm with thin-section computed tomography (CT) in the detection of pulmonary nodules and to evaluate detection sensitivity at a varying range of nodule density, size, and location. A cross-sectional prospective study was conducted on 20 patients with 322 suspected nodules who underwent diagnostic chest imaging using 64-row multi-detector CT. The examinations were evaluated on reconstructed images of 1.4 mm thickness and 0.7 mm interval. Detection of pulmonary nodules, initially by a radiologist of 2 years experience (RAD) and later by CAD lung nodule software was assessed. Then, CAD nodule candidates were accepted or rejected accordingly. Detected nodules were classified based on their size, density, and location. The performance of the RAD and CAD system was compared with the gold standard that is true nodules confirmed by consensus of senior RAD and CAD together. The overall sensitivity and false-positive (FP) rate of CAD software was calculated. Of the 322 suspected nodules, 221 were classified as true nodules on the consensus of senior RAD and CAD together. Of the true nodules, the RAD detected 206 (93.2%) and 202 (91.4%) by the CAD. CAD and RAD together picked up more number of nodules than either CAD or RAD alone. Overall sensitivity for nodule detection with the CAD program was 91.4%, and FP detection per patient was 5.5%. The CAD showed comparatively higher sensitivity for nodules of size 4-10 mm (93.4%) and nodules in hilar (100%) and central (96.5%) location when compared to RAD's performance. CAD performance was high in detecting pulmonary nodules including the small size and low-density nodules. CAD even with relatively high FP rate, assists and improves RAD's performance as a second reader, especially for nodules located in the central and hilar region and for small nodules by saving RADs time.
Hannukainen, J C; Lautamäki, R; Mari, A; Pärkkä, J P; Bucci, M; Guzzardi, M A; Kajander, S; Tuokkola, T; Knuuti, J; Iozzo, P
2016-07-01
Insulin resistance, β-cell dysfunction, and ectopic fat deposition have been implicated in the pathogenesis of coronary artery disease (CAD) and type 2 diabetes, which is common in CAD patients. We investigated whether CAD is an independent predictor of these metabolic abnormalities and whether this interaction is influenced by superimposed myocardial ischemia. We studied CAD patients with (n = 8) and without (n = 14) myocardial ischemia and eight non-CAD controls. Insulin sensitivity and secretion and substrate oxidation were measured during fasting and oral glucose tolerance testing. We used magnetic resonance imaging/spectroscopy, positron emission and computerized tomography to characterize CAD, cardiac function, pericardial and abdominal adipose tissue, and myocardial, liver, and pancreatic triglyceride contents. Ischemic CAD was characterized by elevated oxidative glucose metabolism and a proportional decline in β-cell insulin secretion and reduction in lipid oxidation. Cardiac function was preserved in CAD groups, whereas cardiac fat depots were elevated in ischemic CAD compared to non-CAD subjects. Liver and pancreatic fat contents were similar in all groups and related with surrounding adipose masses or systemic insulin sensitivity. In ischemic CAD patients, glucose oxidation is enhanced and correlates inversely with insulin secretion. This can be seen as a mechanism to prevent glucose lowering because glucose is required in oxygen-deprived tissues. On the other hand, the accumulation of cardiac triglycerides may be a physiological adaptation to the limited fatty acid oxidative capacity. Our results underscore the urgent need of clinical trials that define the optimal/safest glycemic range in situations of myocardial ischemia.
Hannukainen, J. C.; Lautamäki, R.; Mari, A.; Pärkkä, J. P.; Bucci, M.; Guzzardi, M. A.; Kajander, S.; Tuokkola, T.; Knuuti, J.
2016-01-01
Background: Insulin resistance, β-cell dysfunction, and ectopic fat deposition have been implicated in the pathogenesis of coronary artery disease (CAD) and type 2 diabetes, which is common in CAD patients. We investigated whether CAD is an independent predictor of these metabolic abnormalities and whether this interaction is influenced by superimposed myocardial ischemia. Methods and Results: We studied CAD patients with (n = 8) and without (n = 14) myocardial ischemia and eight non-CAD controls. Insulin sensitivity and secretion and substrate oxidation were measured during fasting and oral glucose tolerance testing. We used magnetic resonance imaging/spectroscopy, positron emission and computerized tomography to characterize CAD, cardiac function, pericardial and abdominal adipose tissue, and myocardial, liver, and pancreatic triglyceride contents. Ischemic CAD was characterized by elevated oxidative glucose metabolism and a proportional decline in β-cell insulin secretion and reduction in lipid oxidation. Cardiac function was preserved in CAD groups, whereas cardiac fat depots were elevated in ischemic CAD compared to non-CAD subjects. Liver and pancreatic fat contents were similar in all groups and related with surrounding adipose masses or systemic insulin sensitivity. Conclusions: In ischemic CAD patients, glucose oxidation is enhanced and correlates inversely with insulin secretion. This can be seen as a mechanism to prevent glucose lowering because glucose is required in oxygen-deprived tissues. On the other hand, the accumulation of cardiac triglycerides may be a physiological adaptation to the limited fatty acid oxidative capacity. Our results underscore the urgent need of clinical trials that define the optimal/safest glycemic range in situations of myocardial ischemia. PMID:27045985
Application programs written by using customizing tools of a computer-aided design system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, X.; Huang, R.; Juricic, D.
1995-12-31
Customizing tools of Computer-Aided Design Systems have been developed to such a degree as to become equivalent to powerful higher-level programming languages that are especially suitable for graphics applications. Two examples of application programs written by using AutoCAD`s customizing tools are given in some detail to illustrate their power. One tool uses AutoLISP list-processing language to develop an application program that produces four views of a given solid model. The other uses AutoCAD Developmental System, based on program modules written in C, to produce an application program that renders a freehand sketch from a given CAD drawing.
GPU-accelerated depth map generation for X-ray simulations of complex CAD geometries
NASA Astrophysics Data System (ADS)
Grandin, Robert J.; Young, Gavin; Holland, Stephen D.; Krishnamurthy, Adarsh
2018-04-01
Interactive x-ray simulations of complex computer-aided design (CAD) models can provide valuable insights for better interpretation of the defect signatures such as porosity from x-ray CT images. Generating the depth map along a particular direction for the given CAD geometry is the most compute-intensive step in x-ray simulations. We have developed a GPU-accelerated method for real-time generation of depth maps of complex CAD geometries. We preprocess complex components designed using commercial CAD systems using a custom CAD module and convert them into a fine user-defined surface tessellation. Our CAD module can be used by different simulators as well as handle complex geometries, including those that arise from complex castings and composite structures. We then make use of a parallel algorithm that runs on a graphics processing unit (GPU) to convert the finely-tessellated CAD model to a voxelized representation. The voxelized representation can enable heterogeneous modeling of the volume enclosed by the CAD model by assigning heterogeneous material properties in specific regions. The depth maps are generated from this voxelized representation with the help of a GPU-accelerated ray-casting algorithm. The GPU-accelerated ray-casting method enables interactive (> 60 frames-per-second) generation of the depth maps of complex CAD geometries. This enables arbitrarily rotation and slicing of the CAD model, leading to better interpretation of the x-ray images by the user. In addition, the depth maps can be used to aid directly in CT reconstruction algorithms.
The health farm concept in the primary prevention of coronary artery disease.
Ahmad, A M
1995-12-01
The purpose of the study is as a preliminary outline of the effectiveness of initiating high-risk individuals into the Health Farm concept in the primary prevention of coronary artery disease (CAD). Thirty-five (35) Army personnel, all male, with risk-factors for CAD were brought together on a Health Farm concept to go through a predesigned ten-day Farm programme comprising CAD risk-assessment, comprehensive medical examination, relevant blood chemistry analysis, physical fitness evaluation, individualised weekly exercise routine, physical fitness workouts, individualised diet, lectures, group discussion and individual counselling. Description of the participants (as measurements of various relevant parameters) are made at the start and as participant-achievement. The results show general participant-compliance to the programme which was reflected by significant changes in weight (p < 0.005), percentile VO2Max (p < 0.005), percentile push-ups (p < 0.005) and girth-difference (p < 0.005). The study showed that the Health Farm concept is effective in initiating high-risk individuals into lifestyles conducive to the primary prevention of CAD. Sustained results towards primary prevention of CAD can be expected with compliance to a long-term follow-up that has been identified and to which participants have been made aware of. Other previous intervention studies are briefly discussed.
A Geometry Based Infra-Structure for Computational Analysis and Design
NASA Technical Reports Server (NTRS)
Haimes, Robert
1998-01-01
The computational steps traditionally taken for most engineering analysis suites (computational fluid dynamics (CFD), structural analysis, heat transfer and etc.) are: (1) Surface Generation -- usually by employing a Computer Assisted Design (CAD) system; (2) Grid Generation -- preparing the volume for the simulation; (3) Flow Solver -- producing the results at the specified operational point; (4) Post-processing Visualization -- interactively attempting to understand the results. For structural analysis, integrated systems can be obtained from a number of commercial vendors. These vendors couple directly to a number of CAD systems and are executed from within the CAD Graphical User Interface (GUI). It should be noted that the structural analysis problem is more tractable than CFD; there are fewer mesh topologies used and the grids are not as fine (this problem space does not have the length scaling issues of fluids). For CFD, these steps have worked well in the past for simple steady-state simulations at the expense of much user interaction. The data was transmitted between phases via files. In most cases, the output from a CAD system could go to Initial Graphics Exchange Specification (IGES) or Standard Exchange Program (STEP) files. The output from Grid Generators and Solvers do not really have standards though there are a couple of file formats that can be used for a subset of the gridding (i.e. PLOT3D data formats). The user would have to patch up the data or translate from one format to another to move to the next step. Sometimes this could take days. Specifically the problems with this procedure are:(1) File based -- Information flows from one step to the next via data files with formats specified for that procedure. File standards, when they exist, are wholly inadequate. For example, geometry from CAD systems (transmitted via IGES files) is defined as disjoint surfaces and curves (as well as masses of other information of no interest for the Grid Generator). This is particularly onerous for modern CAD systems based on solid modeling. The part was a proper solid and in the translation to IGES has lost this important characteristic. STEP is another standard for CAD data that exists and supports the concept of a solid. The problem with STEP is that a solid modeling geometry kernel is required to query and manipulate the data within this type of file. (2) 'Good' Geometry. A bottleneck in getting results from a solver is the construction of proper geometry to be fed to the grid generator. With 'good' geometry a grid can be constructed in tens of minutes (even with a complex configuration) using unstructured techniques. Adroit multi-block methods are not far behind. This means that a million node steady-state solution can be computed on the order of hours (using current high performance computers) starting from this 'good' geometry. Unfortunately, the geometry usually transmitted from the CAD system is not 'good' in the grid generator sense. The grid generator needs smooth closed solid geometry. It can take a week (or more) of interaction with the CAD output (sometimes by hand) before the process can begin. One way Communication. (3) One-way Communication -- All information travels on from one phase to the next. This makes procedures like node adaptation difficult when attempting to add or move nodes that sit on bounding surfaces (when the actual surface data has been lost after the grid generation phase). Until this process can be automated, more complex problems such as multi-disciplinary analysis or using the above procedure for design becomes prohibitive. There is also no way to easily deal with this system in a modular manner. One can only replace the grid generator, for example, if the software reads and writes the same files. Instead of the serial approach to analysis as described above, CAPRI takes a geometry centric approach. This makes the actual geometry (not a discretized version) accessible to all phases of the analysis. The connection to the geometry is made through an Application Programming Interface (API) and NOT a file system. This API isolates the top-level applications (grid generators, solvers and visualization components) from the geometry engine. Also this allows the replacement of one geometry kernel with another, without effecting these top-level applications. For example, if UniGraphics is used as the CAD package then Parasolid (UG's own geometry engine) can be used for all geometric queries so that no solid geometry information is lost in a translation. This is much better than STEP because when the data is queried, the same software is executed as used in the CAD system. Therefore, one analyzes the exact part that is in the CAD system. CAPRI uses the same idea as the commercial structural analysis codes but does not specify control. Software components of the CAD system are used, but the analysis suite, not the CAD operator, specifies the control of the software session. This also means that the license issues (may be) minimized and individuals need not have to know how to operate a CAD system in order to run the suite.
CAD-model-based vision for space applications
NASA Technical Reports Server (NTRS)
Shapiro, Linda G.
1988-01-01
A pose acquisition system operating in space must be able to perform well in a variety of different applications including automated guidance and inspections tasks with many different, but known objects. Since the space station is being designed with automation in mind, there will be CAD models of all the objects, including the station itself. The construction of vision models and procedures directly from the CAD models is the goal of this project. The system that is being designed and implementing must convert CAD models to vision models, predict visible features from a given view point from the vision models, construct view classes representing views of the objects, and use the view class model thus derived to rapidly determine the pose of the object from single images and/or stereo pairs.
HDL subfractions and very early CAD: novel findings from untreated patients in a Chinese cohort.
Zhang, Yan; Zhu, Cheng-Gang; Xu, Rui-Xia; Li, Sha; Li, Xiao-Lin; Guo, Yuan-Lin; Wu, Na-Qiong; Gao, Ying; Qing, Ping; Cui, Chuan-Jue; Sun, Jing; Li, Jian-Jun
2016-08-04
Coronary artery disease (CAD) in very young individuals is a rare disease associated with poor prognosis. However, the role of specific lipoprotein subfractions in very young CAD patients (≤45 years) is not established yet. A total of 734 consecutive CAD subjects were enrolled and were classified as very early (n = 81, ≤45), early (n = 304, male: 45-55; female: 45-65), and late (n = 349, male: >55; female: >65) groups. Meanwhile, a group of non-CAD subjects were also enrolled as controls (n = 56, ≤45). The lipoprotein separation was performed using Lipoprint System. As a result, the very early CAD patients have lower large high-density lipoprotein (HDL) subfraction and higher small low-density lipoprotein (LDL) subfraction (p < 0.05). Although body mass index was inversely related to large HDL subfraction, overweight did not influence its association with very early CAD. In the logistic regression analysis, large HDL was inversely [OR 95% CI: 0.872 (0.825-0.922)] while small LDL was positively [1.038 (1.008-1.069)] related to very early CAD. However, after adjusting potential confounders, the association was only significant for large HDL [0.899 (0.848-0.954)]. This study firstly demonstrated that large HDL subfraction was negatively related to very early CAD suggestive of its important role in very early CAD incidence.
Integration of a CAD System Into an MDO Framework
NASA Technical Reports Server (NTRS)
Townsend, J. C.; Samareh, J. A.; Weston, R. P.; Zorumski, W. E.
1998-01-01
NASA Langley has developed a heterogeneous distributed computing environment, called the Framework for Inter-disciplinary Design Optimization, or FIDO. Its purpose has been to demonstrate framework technical feasibility and usefulness for optimizing the preliminary design of complex systems and to provide a working environment for testing optimization schemes. Its initial implementation has been for a simplified model of preliminary design of a high-speed civil transport. Upgrades being considered for the FIDO system include a more complete geometry description, required by high-fidelity aerodynamics and structures codes and based on a commercial Computer Aided Design (CAD) system. This report presents the philosophy behind some of the decisions that have shaped the FIDO system and gives a brief case study of the problems and successes encountered in integrating a CAD system into the FEDO framework.
A framework for development of an intelligent system for design and manufacturing of stamping dies
NASA Astrophysics Data System (ADS)
Hussein, H. M. A.; Kumar, S.
2014-07-01
An integration of computer aided design (CAD), computer aided process planning (CAPP) and computer aided manufacturing (CAM) is required for development of an intelligent system to design and manufacture stamping dies in sheet metal industries. In this paper, a framework for development of an intelligent system for design and manufacturing of stamping dies is proposed. In the proposed framework, the intelligent system is structured in form of various expert system modules for different activities of design and manufacturing of dies. All system modules are integrated with each other. The proposed system takes its input in form of a CAD file of sheet metal part, and then system modules automate all tasks related to design and manufacturing of stamping dies. Modules are coded using Visual Basic (VB) and developed on the platform of AutoCAD software.
Genetically determined height and coronary artery disease.
Nelson, Christopher P; Hamby, Stephen E; Saleheen, Danish; Hopewell, Jenna C; Zeng, Lingyao; Assimes, Themistocles L; Kanoni, Stavroula; Willenborg, Christina; Burgess, Stephen; Amouyel, Phillipe; Anand, Sonia; Blankenberg, Stefan; Boehm, Bernhard O; Clarke, Robert J; Collins, Rory; Dedoussis, George; Farrall, Martin; Franks, Paul W; Groop, Leif; Hall, Alistair S; Hamsten, Anders; Hengstenberg, Christian; Hovingh, G Kees; Ingelsson, Erik; Kathiresan, Sekar; Kee, Frank; König, Inke R; Kooner, Jaspal; Lehtimäki, Terho; März, Winifred; McPherson, Ruth; Metspalu, Andres; Nieminen, Markku S; O'Donnell, Christopher J; Palmer, Colin N A; Peters, Annette; Perola, Markus; Reilly, Muredach P; Ripatti, Samuli; Roberts, Robert; Salomaa, Veikko; Shah, Svati H; Schreiber, Stefan; Siegbahn, Agneta; Thorsteinsdottir, Unnur; Veronesi, Giovani; Wareham, Nicholas; Willer, Cristen J; Zalloua, Pierre A; Erdmann, Jeanette; Deloukas, Panos; Watkins, Hugh; Schunkert, Heribert; Danesh, John; Thompson, John R; Samani, Nilesh J
2015-04-23
The nature and underlying mechanisms of an inverse association between adult height and the risk of coronary artery disease (CAD) are unclear. We used a genetic approach to investigate the association between height and CAD, using 180 height-associated genetic variants. We tested the association between a change in genetically determined height of 1 SD (6.5 cm) with the risk of CAD in 65,066 cases and 128,383 controls. Using individual-level genotype data from 18,249 persons, we also examined the risk of CAD associated with the presence of various numbers of height-associated alleles. To identify putative mechanisms, we analyzed whether genetically determined height was associated with known cardiovascular risk factors and performed a pathway analysis of the height-associated genes. We observed a relative increase of 13.5% (95% confidence interval [CI], 5.4 to 22.1; P<0.001) in the risk of CAD per 1-SD decrease in genetically determined height. There was a graded relationship between the presence of an increased number of height-raising variants and a reduced risk of CAD (odds ratio for height quartile 4 versus quartile 1, 0.74; 95% CI, 0.68 to 0.84; P<0.001). Of the 12 risk factors that we studied, we observed significant associations only with levels of low-density lipoprotein cholesterol and triglycerides (accounting for approximately 30% of the association). We identified several overlapping pathways involving genes associated with both development and atherosclerosis. There is a primary association between a genetically determined shorter height and an increased risk of CAD, a link that is partly explained by the association between shorter height and an adverse lipid profile. Shared biologic processes that determine achieved height and the development of atherosclerosis may explain some of the association. (Funded by the British Heart Foundation and others.).
Sandblasting may damage the surface of composite CAD-CAM blocks.
Yoshihara, Kumiko; Nagaoka, Noriyuki; Maruo, Yukinori; Nishigawa, Goro; Irie, Masao; Yoshida, Yasuhiro; Van Meerbeek, Bart
2017-03-01
CAD-CAM blocks to fabricate semi-direct and indirect restorations are available in different sorts of ceramics as well as composite. In order to bond restorations prepared out of composite blocks into tooth cavities, it is recommended to gently sandblast the surface prior to the application of a primer/adhesive. Today, the effect of sandblasting composite block surfaces has not thoroughly been investigated. In this study, the ultra-structure of composite CAD-CAM blocks was investigated with special attention to the effect of sandblasting on the surface topography and of silanization on the bonding performance. Five different composite CAD-CAM blocks were involved. We correlatively investigated their structural and chemical composition using X-ray diffraction (XRD), energy dispersion spectroscopy (EDS), scanning electron microscopy (SEM) and (scanning) transmission electron microscopy ((S)TEM). The effect of sandblasting was also imaged in cross-section and at the interface with composite cement. Finally, we measured the shear bond strength to the sandblasted block surface with and without silanization. All composite blocks revealed a different ultra-structure. Sandblasting increased surface roughness and resulted in an irregular surface with some filler exposure. Sandblasting also damaged the surface. When the sandblasted composite blocks were silanized, superior bonding receptiveness in terms of higher bond strength was achieved except for Shofu Block HC. Sandblasting followed by silanization improved the bond strength to composite CAD-CAM blocks. However, sandblasting may also damage the composite CAD-CAM block surface. For the composite CAD-CAM block Shofu Block HC, the damage was so severe that silanization did not improve bond strength. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Bao, X D
2018-04-09
The strength of endodontically treated teeth were reduced apparently because of structural damage, therefore further reduction of healthy tissue should be avoided as much as possible in restoration. Endocrown made by chair-side CAD/CAM is some kind of minimal invasive restoration, and the retention of restoration is achieved by reliable bonding and macromechanial retention forces. Without post preparation, the root structure could be resevered. Following the indications and use of biomechanical dentin-like CAD/CAM materials could reduce the adverse effect of tensile stress on cervical part.
Enhancing image classification models with multi-modal biomarkers
NASA Astrophysics Data System (ADS)
Caban, Jesus J.; Liao, David; Yao, Jianhua; Mollura, Daniel J.; Gochuico, Bernadette; Yoo, Terry
2011-03-01
Currently, most computer-aided diagnosis (CAD) systems rely on image analysis and statistical models to diagnose, quantify, and monitor the progression of a particular disease. In general, CAD systems have proven to be effective at providing quantitative measurements and assisting physicians during the decision-making process. As the need for more flexible and effective CADs continues to grow, questions about how to enhance their accuracy have surged. In this paper, we show how statistical image models can be augmented with multi-modal physiological values to create more robust, stable, and accurate CAD systems. In particular, this paper demonstrates how highly correlated blood and EKG features can be treated as biomarkers and used to enhance image classification models designed to automatically score subjects with pulmonary fibrosis. In our results, a 3-5% improvement was observed when comparing the accuracy of CADs that use multi-modal biomarkers with those that only used image features. Our results show that lab values such as Erythrocyte Sedimentation Rate and Fibrinogen, as well as EKG measurements such as QRS and I:40, are statistically significant and can provide valuable insights about the severity of the pulmonary fibrosis disease.
Pombinho, Rita; Camejo, Ana; Vieira, Ana; Reis, Olga; Carvalho, Filipe; Almeida, Maria Teresa; Pinheiro, Jorge Campos; Sousa, Sandra; Cabanes, Didier
2017-05-01
Listeria monocytogenes is a major intracellular human foodborne bacterial pathogen. We previously revealed L. monocytogenes cadC as highly expressed during mouse infection. Here we show that L. monocytogenes CadC is a sequence-specific, DNA-binding and cadmium-dependent regulator of CadA, an efflux pump conferring cadmium resistance. CadC but not CadA is required for L. monocytogenes infection in vivo. Interestingly, CadC also directly represses lspB, a gene encoding a lipoprotein signal peptidase whose expression appears detrimental for infection. lspB overexpression promotes the release of the LpeA lipoprotein to the extracellular medium, inducing tumor necrosis factor α and interleukin 6 expression, thus impairing L. monocytogenes survival in macrophages. We propose that L. monocytogenes uses CadC to repress lspB expression during infection to avoid LpeA exposure to the host immune system, diminishing inflammatory cytokine expression and promoting intramacrophagic survival and virulence. CadC appears as the first metal efflux pump regulator repurposed during infection to fine-tune lipoprotein processing and host responses. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.
Comparative fracture strength analysis of Lava and Digident CAD/CAM zirconia ceramic crowns
Kwon, Taek-Ka; Pak, Hyun-Soon; Han, Jung-Suk; Lee, Jai-Bong; Kim, Sung-Hun
2013-01-01
PURPOSE All-ceramic crowns are subject to fracture during function. To minimize this common clinical complication, zirconium oxide has been used as the framework for all-ceramic crowns. The aim of this study was to compare the fracture strengths of two computer-aided design/computer-aided manufacturing (CAD/CAM) zirconia crown systems: Lava and Digident. MATERIALS AND METHODS Twenty Lava CAD/CAM zirconia crowns and twenty Digident CAD/CAM zirconia crowns were fabricated. A metal die was also duplicated from the original prepared tooth for fracture testing. A universal testing machine was used to determine the fracture strength of the crowns. RESULTS The mean fracture strengths were as follows: 54.9 ± 15.6 N for the Lava CAD/CAM zirconia crowns and 87.0 ± 16.0 N for the Digident CAD/CAM zirconia crowns. The difference between the mean fracture strengths of the Lava and Digident crowns was statistically significant (P<.001). Lava CAD/CAM zirconia crowns showed a complete fracture of both the veneering porcelain and the core whereas the Digident CAD/CAM zirconia crowns showed fracture only of the veneering porcelain. CONCLUSION The fracture strengths of CAD/CAM zirconia crowns differ depending on the compatibility of the core material and the veneering porcelain. PMID:23755332
Optical properties of CAD-CAM ceramic systems.
Della Bona, Alvaro; Nogueira, Audrea D; Pecho, Oscar E
2014-09-01
To evaluate the direct transmittance (T%), translucency, opacity and opalescence of CAD-CAM ceramic systems and the correlation between the translucency parameter (TP) and the contrast ratio (CR). Specimens of shades A1, A2 and A3 (n=5) were fabricated from CAD-CAM ceramic blocks (IPS e.max(®) CAD HT and LT, IPS Empress(®) CAD HT and LT, Paradigm™ C, and VITABLOCS(®) Mark II) and polished to 1.0±0.01mm in thickness. A spectrophotometer (Lambda 20) was used to measure T% on the wavelength range of 400-780nm. Another spectrophotometer (VITA Easyshade(®) Advance) was used to measure the CIE L(*)a(*)b(*) coordinates and the reflectance value (Y) of samples on white and black backgrounds. TP, CR and the opalescence parameter (OP) were calculated. Data were statistically analysed using VAF (variance accounting for) coefficient with Cauchy-Schwarz inequality, one-way ANOVA, Tukey's test, Bonferroni correction and Pearson's correlation. T% of some ceramic systems is dependent on the wavelength. The spectral behaviour showed a slight and constant increase in T% up to approximately 550nm, then some ceramics changed the behaviour as the wavelength gets longer. TP and CR values ranged, respectively, from 16.79 to 21.69 and from 0.52 to 0.64 (r(2)=-0.97). OP values ranged from 3.01 to 7.64. The microstructure of CAD-CAM ceramic systems influenced the optical properties. TP and CR showed a strong correlation for all ceramic systems evaluated. Yet, all ceramics showed some degree of light transmittance. In addition to shade, this study showed that other optical properties influence on the natural appearance of dental ceramics. Copyright © 2014 Elsevier Ltd. All rights reserved.
Detection of Anomalous Insiders in Collaborative Environments via Relational Analysis of Access Logs
Chen, You; Malin, Bradley
2014-01-01
Collaborative information systems (CIS) are deployed within a diverse array of environments, ranging from the Internet to intelligence agencies to healthcare. It is increasingly the case that such systems are applied to manage sensitive information, making them targets for malicious insiders. While sophisticated security mechanisms have been developed to detect insider threats in various file systems, they are neither designed to model nor to monitor collaborative environments in which users function in dynamic teams with complex behavior. In this paper, we introduce a community-based anomaly detection system (CADS), an unsupervised learning framework to detect insider threats based on information recorded in the access logs of collaborative environments. CADS is based on the observation that typical users tend to form community structures, such that users with low a nity to such communities are indicative of anomalous and potentially illicit behavior. The model consists of two primary components: relational pattern extraction and anomaly detection. For relational pattern extraction, CADS infers community structures from CIS access logs, and subsequently derives communities, which serve as the CADS pattern core. CADS then uses a formal statistical model to measure the deviation of users from the inferred communities to predict which users are anomalies. To empirically evaluate the threat detection model, we perform an analysis with six months of access logs from a real electronic health record system in a large medical center, as well as a publicly-available dataset for replication purposes. The results illustrate that CADS can distinguish simulated anomalous users in the context of real user behavior with a high degree of certainty and with significant performance gains in comparison to several competing anomaly detection models. PMID:25485309
CAD/CAM in dentistry: a historical perspective and view of the future.
Rekow, E D
1992-04-01
What can we look forward too? Lots of fun with new CAD/CAM systems that will enhance dentistry, providing quality restorations quickly. The evolution of an array of new versions of already available systems as well as altogether new systems will provide improved quality, expanded capabilities, and increasing user friendliness. And new materials will be more esthetic, wear more nearly like enamel, and strong enough for full crowns and bridges. We can also look forward to lots of change. Because of the cost of CAD/CAM systems, many clinicians are likely to collaborate by sharing a single system. Laboratories and clinicians may collaborate as well, with data being gathered in the operatory and sent to a laboratory via modem. The fabrication would then be done by the laboratory. Other changes that we cannot even predict are likely to occur in dentistry. Exciting times are here. Automation through dental CAD/CAM systems will, most certainly, change the profession. The impact of that change will only be known in the future. But as the future approaches, the systems and materials available to us will continue to evolve, improve, and enhance dentistry.
Computer Aided Design in Engineering Education.
ERIC Educational Resources Information Center
Gobin, R.
1986-01-01
Discusses the use of Computer Aided Design (CAD) and Computer Aided Manufacturing (CAM) systems in an undergraduate engineering education program. Provides a rationale for CAD/CAM use in the already existing engineering program. Describes the methods used in choosing the systems, some initial results, and warnings for first-time users. (TW)
Maroules, Christopher D; Hamilton-Craig, Christian; Branch, Kelley; Lee, James; Cury, Roberto C; Maurovich-Horvat, Pál; Rubinshtein, Ronen; Thomas, Dustin; Williams, Michelle; Guo, Yanshu; Cury, Ricardo C
The Coronary Artery Disease Reporting and Data System (CAD-RADS) provides a lexicon and standardized reporting system for coronary CT angiography. To evaluate inter-observer agreement of the CAD-RADS among an panel of early career and expert readers. Four early career and four expert cardiac imaging readers prospectively and independently evaluated 50 coronary CT angiography cases using the CAD-RADS lexicon. All readers assessed image quality using a five-point Likert scale, with mean Likert score ≥4 designating high image quality, and <4 designating moderate/low image quality. All readers were blinded to medical history and invasive coronary angiography findings. Inter-observer agreement for CAD-RADS assessment categories and modifiers were assessed using intra-class correlation (ICC) and Fleiss' Kappa (κ).The impact of reader experience and image quality on inter-observer agreement was also examined. Inter-observer agreement for CAD-RADS assessment categories was excellent (ICC 0.958, 95% CI 0.938-0.974, p < 0.0001). Agreement among expert readers (ICC 0.925, 95% CI 0.884-0.954) was marginally stronger than for early career readers (ICC 0.904, 95% CI 0.852-0.941), both p < 0.0001. High image quality was associated with stronger agreement than moderate image quality (ICC 0.944, 95% CI 0.886-0.974 vs. ICC 0.887, 95% CI 0.775-0.95, both p < 0.0001). While excellent inter-observer agreement was observed for modifiers S (stent) and G (bypass graft) (both κ = 1.0), only fair agreement (κ = 0.40) was observed for modifier V (high risk plaque). Inter-observer reproducibility of CAD-RADS assessment categories and modifiers is excellent, except for high-risk plaque (modifier V) which demonstrates fair agreement. These results suggest CAD-RADS is feasible for clinical implementation. Copyright © 2017. Published by Elsevier Inc.
NASA Astrophysics Data System (ADS)
Qiu, Yuchen; Wang, Xingwei; Chen, Xiaodong; Li, Yuhua; Liu, Hong; Li, Shibo; Zheng, Bin
2010-02-01
Visually searching for analyzable metaphase chromosome cells under microscopes is quite time-consuming and difficult. To improve detection efficiency, consistency, and diagnostic accuracy, an automated microscopic image scanning system was developed and tested to directly acquire digital images with sufficient spatial resolution for clinical diagnosis. A computer-aided detection (CAD) scheme was also developed and integrated into the image scanning system to search for and detect the regions of interest (ROI) that contain analyzable metaphase chromosome cells in the large volume of scanned images acquired from one specimen. Thus, the cytogeneticists only need to observe and interpret the limited number of ROIs. In this study, the high-resolution microscopic image scanning and CAD performance was investigated and evaluated using nine sets of images scanned from either bone marrow (three) or blood (six) specimens for diagnosis of leukemia. The automated CAD-selection results were compared with the visual selection. In the experiment, the cytogeneticists first visually searched for the analyzable metaphase chromosome cells from specimens under microscopes. The specimens were also automated scanned and followed by applying the CAD scheme to detect and save ROIs containing analyzable cells while deleting the others. The automated selected ROIs were then examined by a panel of three cytogeneticists. From the scanned images, CAD selected more analyzable cells than initially visual examinations of the cytogeneticists in both blood and bone marrow specimens. In general, CAD had higher performance in analyzing blood specimens. Even in three bone marrow specimens, CAD selected 50, 22, 9 ROIs, respectively. Except matching with the initially visual selection of 9, 7, and 5 analyzable cells in these three specimens, the cytogeneticists also selected 41, 15 and 4 new analyzable cells, which were missed in initially visual searching. This experiment showed the feasibility of applying this CAD-guided high-resolution microscopic image scanning system to prescreen and select ROIs that may contain analyzable metaphase chromosome cells. The success and the further improvement of this automated scanning system may have great impact on the future clinical practice in genetic laboratories to detect and diagnose diseases.
NASA Technical Reports Server (NTRS)
Rasmussen, John
1990-01-01
Structural optimization has attracted the attention since the days of Galileo. Olhoff and Taylor have produced an excellent overview of the classical research within this field. However, the interest in structural optimization has increased greatly during the last decade due to the advent of reliable general numerical analysis methods and the computer power necessary to use them efficiently. This has created the possibility of developing general numerical systems for shape optimization. Several authors, eg., Esping; Braibant & Fleury; Bennet & Botkin; Botkin, Yang, and Bennet; and Stanton have published practical and successful applications of general optimization systems. Ding and Homlein have produced extensive overviews of available systems. Furthermore, a number of commercial optimization systems based on well-established finite element codes have been introduced. Systems like ANSYS, IDEAS, OASIS, and NISAOPT are widely known examples. In parallel to this development, the technology of computer aided design (CAD) has gained a large influence on the design process of mechanical engineering. The CAD technology has already lived through a rapid development driven by the drastically growing capabilities of digital computers. However, the systems of today are still considered as being only the first generation of a long row of computer integrated manufacturing (CIM) systems. These systems to come will offer an integrated environment for design, analysis, and fabrication of products of almost any character. Thus, the CAD system could be regarded as simply a database for geometrical information equipped with a number of tools with the purpose of helping the user in the design process. Among these tools are facilities for structural analysis and optimization as well as present standard CAD features like drawing, modeling, and visualization tools. The state of the art of structural optimization is that a large amount of mathematical and mechanical techniques are available for the solution of single problems. By implementing collections of the available techniques into general software systems, operational environments for structural optimization have been created. The forthcoming years must bring solutions to the problem of integrating such systems into more general design environments. The result of this work should be CAD systems for rational design in which structural optimization is one important design tool among many others.
Conti, A; Angeli, E; Trausi, F; Grifoni, C; Lazzeretti, D; Bianchi, S; Catarzi, S; Covelli, A; Perrotta, M E; Lencioni, A M; Pisani, N; Bertolini, L
2015-06-01
Atrial fibrillation (AF), the most common cardiac-arrhythmia in critical-care, has reached a high prevalence in hypertensive patients. Prevention of systemic-embolism is mandatory; unfortunately, evidence to support the treatment of comorbidities as coronary artery disease (CAD) that contribute to excess mortality is lacking, and the mechanism underlying the troponin-rise during AF without acute coronary syndrome (ACS) is unclear. This study investigates the relationship between CAD, stroke and outcomes in patients with troponin-rise and AF. Patients with a recent-onset AF and without severe comorbidities were enrolled. Baseline characteristics in those with troponin-rise versus those without were adjusted with propensity-score-matching for possible confounders. SPSS-software allowed estimation of the propensity-score using logistic-regression and specifying nearest-neighbor matching in prior-stroke, heart-rate, hypertension, TIMI-risk-score, GRACE-score, CHA2DS2Vasc-score. Patients with a troponin-rise or cardiovascular event (CVE) were considered for angiography. The primary endpoint was the composite of ACS, revascularization (with critical CAD>/ = 70%) and cardiac-death at the follow-up; the secondary endpoint was stroke. Out of 6203 AF patients without severe comorbidities, 3541 with recent-onset AF completed the study; 202(6%) showed a troponin-rise, 91(3%) a CVE. After matching no difference existed in baseline characteristics. On multivariate analysis, in the entire cohort, troponin-rise, know-CAD and hypertension were predictors of the endpoint, whereas only troponin-rise (Odd Ratio, OR: 10, Confidence Interval 95%, CI: 4-22, p < 0.001) and TIMI-score > 2 (OR 4, CI 2-9, p < 0.001) in the matching cohort, suggesting the role of CAD in poor outcomes. Patients with or without troponin-rise achieved the endpoint in 38(19%) and 43(1%), respectively (p < 0.001). Stroke occurred in 4(2%) and 20 (1%), respectively (p = 0.018). Critical CAD account for 23(12%) and 15(1%), respectively (p < 0,001). In the matching cohort, only stroke did not reach the statistical significance. Interestingly, the best cut/off troponin level for decision-making was 0.30 ng/L which, on Receiver Operator Curve analysis, was associated with 68% of sensitivity and 60% specificity; the value > 0.50 ng/L with 55% and 75%, respectively. Patients with a recent-onset AF and troponin-rise showed a high prevalence of CVE but not stroke, thus CAD might have a role in poor outcomes.
Dessouky, Mohamed M; Elrashidy, Mohamed A; Taha, Taha E; Abdelkader, Hatem M
2016-05-01
The different discrete transform techniques such as discrete cosine transform (DCT), discrete sine transform (DST), discrete wavelet transform (DWT), and mel-scale frequency cepstral coefficients (MFCCs) are powerful feature extraction techniques. This article presents a proposed computer-aided diagnosis (CAD) system for extracting the most effective and significant features of Alzheimer's disease (AD) using these different discrete transform techniques and MFCC techniques. Linear support vector machine has been used as a classifier in this article. Experimental results conclude that the proposed CAD system using MFCC technique for AD recognition has a great improvement for the system performance with small number of significant extracted features, as compared with the CAD system based on DCT, DST, DWT, and the hybrid combination methods of the different transform techniques. © The Author(s) 2015.
Automated characterization of diabetic foot using nonlinear features extracted from thermograms
NASA Astrophysics Data System (ADS)
Adam, Muhammad; Ng, Eddie Y. K.; Oh, Shu Lih; Heng, Marabelle L.; Hagiwara, Yuki; Tan, Jen Hong; Tong, Jasper W. K.; Acharya, U. Rajendra
2018-03-01
Diabetic foot is a major complication of diabetes mellitus (DM). The blood circulation to the foot decreases due to DM and hence, the temperature reduces in the plantar foot. Thermography is a non-invasive imaging method employed to view the thermal patterns using infrared (IR) camera. It allows qualitative and visual documentation of temperature fluctuation in vascular tissues. But it is difficult to diagnose these temperature changes manually. Thus, computer assisted diagnosis (CAD) system may help to accurately detect diabetic foot to prevent traumatic outcomes such as ulcerations and lower extremity amputation. In this study, plantar foot thermograms of 33 healthy persons and 33 individuals with type 2 diabetes are taken. These foot images are decomposed using discrete wavelet transform (DWT) and higher order spectra (HOS) techniques. Various texture and entropy features are extracted from the decomposed images. These combined (DWT + HOS) features are ranked using t-values and classified using support vector machine (SVM) classifier. Our proposed methodology achieved maximum accuracy of 89.39%, sensitivity of 81.81% and specificity of 96.97% using only five features. The performance of the proposed thermography-based CAD system can help the clinicians to take second opinion on their diagnosis of diabetic foot.
Deep Convolutional Neural Networks for breast cancer screening.
Chougrad, Hiba; Zouaki, Hamid; Alheyane, Omar
2018-04-01
Radiologists often have a hard time classifying mammography mass lesions which leads to unnecessary breast biopsies to remove suspicions and this ends up adding exorbitant expenses to an already burdened patient and health care system. In this paper we developed a Computer-aided Diagnosis (CAD) system based on deep Convolutional Neural Networks (CNN) that aims to help the radiologist classify mammography mass lesions. Deep learning usually requires large datasets to train networks of a certain depth from scratch. Transfer learning is an effective method to deal with relatively small datasets as in the case of medical images, although it can be tricky as we can easily start overfitting. In this work, we explore the importance of transfer learning and we experimentally determine the best fine-tuning strategy to adopt when training a CNN model. We were able to successfully fine-tune some of the recent, most powerful CNNs and achieved better results compared to other state-of-the-art methods which classified the same public datasets. For instance we achieved 97.35% accuracy and 0.98 AUC on the DDSM database, 95.50% accuracy and 0.97 AUC on the INbreast database and 96.67% accuracy and 0.96 AUC on the BCDR database. Furthermore, after pre-processing and normalizing all the extracted Regions of Interest (ROIs) from the full mammograms, we merged all the datasets to build one large set of images and used it to fine-tune our CNNs. The CNN model which achieved the best results, a 98.94% accuracy, was used as a baseline to build the Breast Cancer Screening Framework. To evaluate the proposed CAD system and its efficiency to classify new images, we tested it on an independent database (MIAS) and got 98.23% accuracy and 0.99 AUC. The results obtained demonstrate that the proposed framework is performant and can indeed be used to predict if the mass lesions are benign or malignant. Copyright © 2018 Elsevier B.V. All rights reserved.
Custom hip prostheses by integrating CAD and casting technology
NASA Astrophysics Data System (ADS)
Silva, Pedro F.; Leal, Nuno; Neto, Rui J.; Lino, F. Jorge; Reis, Ana
2012-09-01
Total Hip Arthroplasty (THA) is a surgical intervention that is being achieving high rates of success, leaving room to research on long run durability, patient comfort and costs reduction. Even so, up to the present, little research has been done to improve the method of manufacturing customized prosthesis. The common customized prostheses are made by full machining. This document presents a different approach methodology which combines the study of medical images, through CAD (Computer Aided Design) software, SLadditive manufacturing, ceramic shell manufacture, precision foundry with Titanium alloys and Computer Aided Manufacturing (CAM). The goal is to achieve the best comfort for the patient, stress distribution and the maximum lifetime of the prosthesis produced by this integrated methodology. The way to achieve this desiderate is to make custom hip prosthesis which are adapted to each patient needs and natural physiognomy. Not only the process is reliable, but also represents a cost reduction comparing to the conventional full machined custom hip prosthesis.
Bohner, Lauren Oliveira Lima; Neto, Pedro Tortamano; Ahmed, Ahad Shahid; Mori, Matsuyoshi; Laganá, Dalva Cruz; Sesma, Newton
2016-07-01
The aim of this review was to update the literature with regard to the digital methods available by CEREC Chairside system to register and design the occlusion, to report their efficacy and technical innovations in the field of Restorative Dentistry. A search strategy was performed using the key-words: "virtual articulator," or "CAD-CAM and occlusal recording," or "CAD-CAM and occlusion register," or "CAD-CAM and occlusal contacts," or "CAD-CAM and prosthesis." Inclusion criteria comprised studies evaluating the use of digital methods available by CEREC System for occlusal registration and design during prosthodontics treatment. PubMed and Cochrane library and reference lists were searched up to January 2016. The search resulted in 280 articles after removing duplicates. Subsequently, 233 records were excluded and 49 studies were selected for reading in full. Eleven articles were considered eligible for the systematic review (4 in vitro and 7 clinical studies). Scientific evidence suggests that digital methods were accurate to register and design the occlusion of dental prostheses. Nevertheless, further clinical studies are required to establish a conclusion with regard to its accuracy in prosthodontics treatment. Digital technologies allow the design of occlusal surfaces of CAD-CAM fabricated prostheses using innovative approaches. This systematic review aimed to update the literature to help dentists determine the most appropriate digital method to register and design the occlusal surface of CAD-CAM crowns. (J Esthet Restor Dent 28:208-220, 2016). © 2016 Wiley Periodicals, Inc.
Cymerman, Rachel M; Skolnick, Adam H; Cole, William J; Nabati, Camellia; Curcio, Christine A; Smith, R Theodore
2016-11-01
Reticular macular disease (RMD) is the highest risk form of early age-related macular degeneration and also specifically confers decreased longevity. However, because RMD requires advanced retinal imaging for adequate detection of its characteristic subretinal drusenoid deposits (SDD), it has not yet been completely studied with respect to coronary artery disease (CAD), the leading cause of death in the developed world. Because CAD appears in middle age, our purpose was to screen patients aged 45-80 years, documented either with or without CAD, to determine if CAD is associated with RMD. A prospective cohort study of patients with documented CAD status and no known retinal disease in a clinical practice setting at one institution. Subjects and Controls: A number of 76 eyes from 38 consecutive patients (23 with documented CAD, 15 controls documented without CAD; 47.4% female; mean age 66.7 years). Patients were imaged with near-infrared reflectance/spectral domain optical coherence tomography and assessed in masked fashion by two graders for the presence of SDD lesions of RMD and soft drusen. Presence or absence of RMD/SDD and soft drusen. RMD was more frequent in patients with CAD versus those without (Relative Risk [RR] = 2.1, CI = 1.08-3.95, P = 0.03). There was no association of CAD with soft drusen. A specific relationship between CAD and RMD suggests common systemic causes for both and warrants further study.
Analysis of HOM Problems in the C-ADS Main Linac
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Burn; Ng, King Yuen
2017-05-18
Excitation of higher-order modes (HOMs) in superconducting cavities may severely affect the operation of the main linac in the Chinese Accelerator Driven System (CADS). Preliminary analysis is made on the effects of beam dynamic, which includes possible longitudinal and transverse emittance enlargements, as well as the possibility of beam breakup. Suggestions are given for further investigation. Comparison is made between the C-ADS and the Fermilab Project X.
Integrating three-dimensional digital technologies for comprehensive implant dentistry.
Patel, Neal
2010-06-01
The increase in the popularity of and the demand for the use of dental implants to replace teeth has encouraged advancement in clinical technology and materials to improve patients' acceptance and clinical outcomes. Recent advances such as three-dimensional dental radiography with cone-beam computed tomography (CBCT), precision dental implant planning software and clinical execution with guided surgery all play a role in the success of implant dentistry. The author illustrates the technique of comprehensive implant dentistry planning through integration of computer-aided design/computer-aided manufacturing (CAD/CAM) and CBCT data. The technique includes clinical treatment with guided surgery, including the creation of a final restoration with a high-strength ceramic (IPS e.max CAD, Ivoclar Vivadent, Amherst, N.Y.). The author also introduces a technique involving CAD/CAM for fabricating custom implant abutments. The release of software integrating CEREC Acquisition Center with Bluecam (Sirona Dental Systems, Charlotte, N.C.) chairside CAD/CAM and Galileos CBCT imaging (Sirona Dental Systems) allows dentists to plan implant placement, perform implant dentistry with increased precision and provide predictable restorative results by using chairside IPS e.max CAD. The precision of clinical treatment provided by the integration of CAD/CAM and CBCT allows dentists to plan for ideal surgical placement and the appropriate thickness of restorative modalities before placing implants.
Novel Cadmium Resistance Determinant in Listeria monocytogenes.
Parsons, Cameron; Lee, Sangmi; Jayeola, Victor; Kathariou, Sophia
2017-03-01
Listeria monocytogenes is a foodborne pathogen that can cause severe disease (listeriosis) in susceptible individuals. It is ubiquitous in the environment and often exhibits resistance to heavy metals. One of the determinants that enables Listeria to tolerate exposure to cadmium is the cadAC efflux system, with CadA being a P-type ATPase. Three different cadA genes (designated cadA1 to cadA3 ) were previously characterized in L. monocytogenes A novel putative cadmium resistance gene ( cadA4 ) was recently identified through whole-genome sequencing, but experimental confirmation for its involvement in cadmium resistance is lacking. In this study, we characterized cadA4 in L. monocytogenes strain F8027, a cadmium-resistant strain of serotype 4b. By screening a mariner-based transposon library of this strain, we identified a mutant with reduced tolerance to cadmium and that harbored a single transposon insertion in cadA4 The tolerance to cadmium was restored by genetic complementation with the cadmium resistance cassette ( cadA4C ), and enhanced cadmium tolerance was conferred to two unrelated cadmium-sensitive strains via heterologous complementation with cadA4C Cadmium exposure induced cadA4 expression, even at noninhibitory levels. Virulence assessments in the Galleria mellonella model suggested that a functional cadA4 suppressed virulence, potentially promoting commensal colonization of the insect larvae. Biofilm assays suggested that cadA4 inactivation reduced biofilm formation. These data not only confirm cadA4 as a novel cadmium resistance determinant in L. monocytogenes but also provide evidence for roles in virulence and biofilm formation. IMPORTANCE Listeria monocytogenes is an intracellular foodborne pathogen causing the disease listeriosis, which is responsible for numerous hospitalizations and deaths every year. Among the adaptations that enable the survival of Listeria in the environment are the abilities to persist in biofilms, grow in the cold, and tolerate toxic compounds, such as heavy metals. Here, we characterized a novel determinant that was recently identified on a larger mobile genetic island through whole-genome sequencing. This gene ( cadA4 ) was found to be responsible for cadmium detoxification and to be a divergent member of the Cad family of cadmium efflux pumps. Virulence assessments in a Galleria mellonella model suggested that cadA4 may suppress virulence. Additionally, cadA4 may be involved in the ability of Listeria to form biofilms. Beyond the role in cadmium detoxification, the involvement of cadA4 in other cellular functions potentially explains its retention and wide distribution in L. monocytogenes . Copyright © 2017 American Society for Microbiology.
Balleyguier, Corinne; Arfi-Rouche, Julia; Levy, Laurent; Toubiana, Patrick R; Cohen-Scali, Franck; Toledano, Alicia Y; Boyer, Bruno
2017-12-01
Evaluate concurrent Computer-Aided Detection (CAD) with Digital Breast Tomosynthesis (DBT) to determine impact on radiologist performance and reading time. The CAD system detects and extracts suspicious masses, architectural distortions and asymmetries from DBT planes that are blended into corresponding synthetic images to form CAD-enhanced synthetic images. Review of CAD-enhanced images and navigation to corresponding planes to confirm or dismiss potential lesions allows radiologists to more quickly review DBT planes. A retrospective, crossover study with and without CAD was conducted with six radiologists who read an enriched sample of 80 DBT cases including 23 malignant lesions in 21 women. Area Under the Receiver Operating Characteristic (ROC) Curve (AUC) compared the readings with and without CAD to determine the effect of CAD on overall interpretation performance. Sensitivity, specificity, recall rate and reading time were also assessed. Multi-reader, multi-case (MRMC) methods accounting for correlation and requiring correct lesion localization were used to analyze all endpoints. AUCs were based on a 0-100% probability of malignancy (POM) score. Sensitivity and specificity were based on BI-RADS scores, where 3 or higher was positive. Average AUC across readers without CAD was 0.854 (range: 0.785-0.891, 95% confidence interval (CI): 0.769,0.939) and 0.850 (range: 0.746-0.905, 95% CI: 0.751,0.949) with CAD (95% CI for difference: -0.046,0.039), demonstrating non-inferiority of AUC. Average reduction in reading time with CAD was 23.5% (95% CI: 7.0-37.0% improvement), from an average 48.2 (95% CI: 39.1,59.6) seconds without CAD to 39.1 (95% CI: 26.2,54.5) seconds with CAD. Per-patient sensitivity was the same with and without CAD (0.865; 95% CI for difference: -0.070,0.070), and there was a small 0.022 improvement (95% CI for difference: -0.046,0.089) in per-lesion sensitivity from 0.790 without CAD to 0.812 with CAD. A slight reduction in specificity with a -0.014 difference (95% CI for difference: -0.079,0.050) and a small 0.025 increase (95% CI for difference: -0.036,0.087) in recall rate in non-cancer cases were observed with CAD. Concurrent CAD resulted in faster reading time with non-inferiority of radiologist interpretation performance. Radiologist sensitivity, specificity and recall rate were similar with and without CAD. Copyright © 2017 Elsevier B.V. All rights reserved.
A/E/C CAD Standard, Release 4.0
2009-07-01
Insulating (Transformer) Oil System Lubrication Oil Hot Water Heating System Machine Design Appendix A Model File Level/Layer Assignment Tables A51...of the A /E/C CAD Standard are: “Uniform Drawing System ” The Construction Specifications Institute 99 Canal Center Plaza, Suite 300 Alexandria, VA...FM – Facility Management GIS – Geographic Information System IAI – International Alliance for Interoperability IFC – Industry Foundation
Research on computer-aided design of modern marine power systems
NASA Astrophysics Data System (ADS)
Ding, Dongdong; Zeng, Fanming; Chen, Guojun
2004-03-01
To make the MPS (Marine Power System) design process more economical and easier, a new CAD scheme is brought forward which takes much advantage of VR (Virtual Reality) and AI (Artificial Intelligence) technologies. This CAD system can shorten the period of design and reduce the requirements on designers' experience in large scale. And some key issues like the selection of hardware and software of such a system are discussed.
ERIC Educational Resources Information Center
Nee, John G.; Kare, Audhut P.
1987-01-01
Explores several concepts in computer assisted design/computer assisted manufacturing (CAD/CAM). Defines, evaluates, reviews and compares advanced computer-aided geometric modeling and analysis techniques. Presents the results of a survey to establish the capabilities of minicomputer based-systems with the CAD/CAM packages evaluated. (CW)
Melanoma recognition framework based on expert definition of ABCD for dermoscopic images.
Abbas, Qaisar; Emre Celebi, M; Garcia, Irene Fondón; Ahmad, Waqar
2013-02-01
Melanoma Recognition based on clinical ABCD rule is widely used for clinical diagnosis of pigmented skin lesions in dermoscopy images. However, the current computer-aided diagnostic (CAD) systems for classification between malignant and nevus lesions using the ABCD criteria are imperfect due to use of ineffective computerized techniques. In this study, a novel melanoma recognition system (MRS) is presented by focusing more on extracting features from the lesions using ABCD criteria. The complete MRS system consists of the following six major steps: transformation to the CIEL*a*b* color space, preprocessing to enhance the tumor region, black-frame and hair artifacts removal, tumor-area segmentation, quantification of feature using ABCD criteria and normalization, and finally feature selection and classification. The MRS system for melanoma-nevus lesions is tested on a total of 120 dermoscopic images. To test the performance of the MRS diagnostic classifier, the area under the receiver operating characteristics curve (AUC) is utilized. The proposed classifier achieved a sensitivity of 88.2%, specificity of 91.3%, and AUC of 0.880. The experimental results show that the proposed MRS system can accurately distinguish between malignant and benign lesions. The MRS technique is fully automatic and can easily integrate to an existing CAD system. To increase the classification accuracy of MRS, the CASH pattern recognition technique, visual inspection of dermatologist, contextual information from the patients, and the histopathological tests can be included to investigate the impact with this system. © 2012 John Wiley & Sons A/S.
Prakashini, K; Babu, Satish; Rajgopal, KV; Kokila, K Raja
2016-01-01
Aims and Objectives: To determine the overall performance of an existing CAD algorithm with thin-section computed tomography (CT) in the detection of pulmonary nodules and to evaluate detection sensitivity at a varying range of nodule density, size, and location. Materials and Methods: A cross-sectional prospective study was conducted on 20 patients with 322 suspected nodules who underwent diagnostic chest imaging using 64-row multi-detector CT. The examinations were evaluated on reconstructed images of 1.4 mm thickness and 0.7 mm interval. Detection of pulmonary nodules, initially by a radiologist of 2 years experience (RAD) and later by CAD lung nodule software was assessed. Then, CAD nodule candidates were accepted or rejected accordingly. Detected nodules were classified based on their size, density, and location. The performance of the RAD and CAD system was compared with the gold standard that is true nodules confirmed by consensus of senior RAD and CAD together. The overall sensitivity and false-positive (FP) rate of CAD software was calculated. Observations and Results: Of the 322 suspected nodules, 221 were classified as true nodules on the consensus of senior RAD and CAD together. Of the true nodules, the RAD detected 206 (93.2%) and 202 (91.4%) by the CAD. CAD and RAD together picked up more number of nodules than either CAD or RAD alone. Overall sensitivity for nodule detection with the CAD program was 91.4%, and FP detection per patient was 5.5%. The CAD showed comparatively higher sensitivity for nodules of size 4–10 mm (93.4%) and nodules in hilar (100%) and central (96.5%) location when compared to RAD's performance. Conclusion: CAD performance was high in detecting pulmonary nodules including the small size and low-density nodules. CAD even with relatively high FP rate, assists and improves RAD's performance as a second reader, especially for nodules located in the central and hilar region and for small nodules by saving RADs time. PMID:27578931
Kobayashi, Hajime; Ohkubo, Masaki; Narita, Akihiro; Marasinghe, Janaka C; Murao, Kohei; Matsumoto, Toru; Sone, Shusuke
2017-01-01
Objective: We propose the application of virtual nodules to evaluate the performance of computer-aided detection (CAD) of lung nodules in cancer screening using low-dose CT. Methods: The virtual nodules were generated based on the spatial resolution measured for a CT system used in an institution providing cancer screening and were fused into clinical lung images obtained at that institution, allowing site specificity. First, we validated virtual nodules as an alternative to artificial nodules inserted into a phantom. In addition, we compared the results of CAD analysis between the real nodules (n = 6) and the corresponding virtual nodules. Subsequently, virtual nodules of various sizes and contrasts between nodule density and background density (ΔCT) were inserted into clinical images (n = 10) and submitted for CAD analysis. Results: In the validation study, 46 of 48 virtual nodules had the same CAD results as artificial nodules (kappa coefficient = 0.913). Real nodules and the corresponding virtual nodules showed the same CAD results. The detection limits of the tested CAD system were determined in terms of size and density of peripheral lung nodules; we demonstrated that a nodule with a 5-mm diameter was detected when the nodule had a ΔCT > 220 HU. Conclusion: Virtual nodules are effective in evaluating CAD performance using site-specific scan/reconstruction conditions. Advances in knowledge: Virtual nodules can be an effective means of evaluating site-specific CAD performance. The methodology for guiding the detection limit for nodule size/density might be a useful evaluation strategy. PMID:27897029
Challoumas, Dimitrios; Stavrou, Antonio; Pericleous, Agamemnon; Dimitrakakis, Georgios
2015-02-01
Despite the growing body of evidence on the potential effects of calcium and vitamin D as monotherapies on different cardiovascular (CV) parameters, the combined supplementation with calcium and vitamin D (CaD), which is most frequently encountered in clinical practice, has not received the attention it deserves. A literature search was conducted via EMBASE and Medline and identified 14 randomised controlled trials (RCTs) and 2 meta-analyses reporting on effects of combined supplementation with CaD on CV events, CV death, blood pressure, lipids, glucose metabolism and weight. Overall, the existing evidence does not support beneficial properties of supplementation with CaD on the CV system, nor does it suggest that a re-appraisal of the use of CaD is necessary due to adverse effects, although increased risk of CV events has been reported by some authors. The guidelines for the use of CaD supplementation need not change until well-conducted RCTs that have CV effects as primary outcomes and adjust for major confounders indicate otherwise. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Qintao, Cui; Yan, Li; Changhong, Duan; Xiaoliang, Guo; Xiaochen, Liu
2014-12-01
Coronary artery disease (CAD) receives intensive research due to its high incidence and severe impact on the quality of life. One member of the matrix metalloproteinases (MMPs), MMP-1, has been reported to be associated with CAD. To identify the markers contributing to the genetic susceptibility to CAD, nine single-nucleotide polymorphisms (rs1799750, rs498186, rs475007, rs514921, rs494379, rs996999, rs2071232, rs1938901, and rs2239008) throughout the MMP-1 gene were genotyped using MALDI-TOF within the MassARRAY system, and the allele and genotype distributions were compared between 438 healthy controls and 411 patients with CAD from a Chinese Han population. The analysis revealed a weak association between the rs1799750 (in the promoter region) genotype distribution and CAD (p=0.022). An increased risk of CAD was significantly associated with the 2G allele of rs1799750 (p=0.005, odds ratio=1.329, 95% confidence interval=1.090-1.620, after Bonferroni corrections). Strong linkage disequilibrium was observed in three blocks (D'>0.9). Significantly more C-2G (rs498186-rs1799750) haplotypes (p=0.001 after Bonferroni corrections) were found in CAD subjects. These findings point to a role for the polymorphism in the MMP-1 promoter in CAD among a Han Chinese population and may be informative for future genetic or biological studies on CAD.
In Vitro Analysis of the Fracture Resistance of CAD/CAM Denture Base Resins.
Steinmassl, Otto; Offermanns, Vincent; Stöckl, Wolfgang; Dumfahrt, Herbert; Grunert, Ingrid; Steinmassl, Patricia-Anca
2018-03-08
Computer-aided design and computer-aided manufacturing (CAD/CAM) denture base manufacturers claim to produce their resin pucks under high heat and pressure. Therefore, CAD/CAM dentures are assumed to have enhanced mechanical properties and, as a result, are often produced with lower denture base thicknesses than conventional, manually fabricated dentures. The aim of this study was to investigate if commercially available CAD/CAM denture base resins have more favourable mechanical properties than conventionally processed denture base resins. For this purpose, a series of three-point bending tests conforming to ISO specifications were performed on a total of 80 standardised, rectangular CAD/CAM denture base resin specimens from five different manufacturers (AvaDent, Baltic Denture System, Vita VIONIC, Whole You Nexteeth, and Wieland Digital Dentures). A heat-polymerising resin and an autopolymerising resin served as the control groups. The breaking load, fracture toughness, and the elastic modulus were assessed. Additionally, the fracture surface roughness and texture were investigated. Only one CAD/CAM resin showed a significantly increased breaking load. Two CAD/CAM resins had a significantly higher fracture toughness than the control groups, and all CAD/CAM resins had higher elastic moduli than the controls. Our results indicate that CAD/CAM denture base resins do not generally have better mechanical properties than manually processed resins. Therefore, the lower minimum denture base thicknesses should be regarded with some caution.
In Vitro Analysis of the Fracture Resistance of CAD/CAM Denture Base Resins
Stöckl, Wolfgang; Dumfahrt, Herbert; Grunert, Ingrid
2018-01-01
Computer-aided design and computer-aided manufacturing (CAD/CAM) denture base manufacturers claim to produce their resin pucks under high heat and pressure. Therefore, CAD/CAM dentures are assumed to have enhanced mechanical properties and, as a result, are often produced with lower denture base thicknesses than conventional, manually fabricated dentures. The aim of this study was to investigate if commercially available CAD/CAM denture base resins have more favourable mechanical properties than conventionally processed denture base resins. For this purpose, a series of three-point bending tests conforming to ISO specifications were performed on a total of 80 standardised, rectangular CAD/CAM denture base resin specimens from five different manufacturers (AvaDent, Baltic Denture System, Vita VIONIC, Whole You Nexteeth, and Wieland Digital Dentures). A heat-polymerising resin and an autopolymerising resin served as the control groups. The breaking load, fracture toughness, and the elastic modulus were assessed. Additionally, the fracture surface roughness and texture were investigated. Only one CAD/CAM resin showed a significantly increased breaking load. Two CAD/CAM resins had a significantly higher fracture toughness than the control groups, and all CAD/CAM resins had higher elastic moduli than the controls. Our results indicate that CAD/CAM denture base resins do not generally have better mechanical properties than manually processed resins. Therefore, the lower minimum denture base thicknesses should be regarded with some caution. PMID:29518022
Initial versus final fracture of metal-free crowns, analyzed via acoustic emission.
Ereifej, Nadia; Silikas, Nick; Watts, David C
2008-09-01
To discriminate between initial and final fracture failure loads of four metal-free crown systems by the conjoint detection of acoustic emission signals during compressive loading. Teeth were prepared and used for crown construction with four crown systems; Vita Mark II (VM II) (Vita Zahnfabrik), IPS e.max Ceram/CAD (CAD) (Ivoclar-Vivadent), IPS e.max Ceram/ZirCAD (ZirCAD) (Ivoclar-Vivadent) and BelleGlass/EverStick (BGES) (Kerr/Stick Tech Ltd.). All samples were loaded in compression via a Co/Cr maxillary first molar tooth at 0.2mm/min and released acoustic signals were collected and analyzed. A minimum number of 15 crowns per group were loaded to final failure and values of loading at initial and final fracture were compared. Additional four samples per group were loaded till fracture initiation and were fractographically examined under the optical microscope. A lower threshold of 50dB was selected to exclude spurious background signals. Initial fracture forces were significantly lower than those of final fracture (p<0.05) in all groups and initial failure AE amplitudes were lower than those of final fracture. Mean initial fracture force of ZirCAD samples (1029.1N) was higher than those of VMII (744.4N), CAD (808.8 N) and BGES (979.7 N). Final fracture of ZirCAD also occurred at significantly higher force values (2091.7 N) than the rest of the groups; VMII (1120.9 N), CAD (1468.9 N) and BGES (1576.6 N). Significantly higher values of initial failure AE amplitude were found in VMII than CAD and BGES while those of final fracture were similar. All crowns observed under the microscope at initial fracture had signs of failure. Whereas the metal-free crowns examined showed significant variations in final failure loads, acoustic emission data showed that they all manifested initial failures at significantly lower load values.
Effectiveness and efficiency of a CAD/CAM orthodontic bracket system.
Brown, Matthew W; Koroluk, Lorne; Ko, Ching-Chang; Zhang, Kai; Chen, Mengqi; Nguyen, Tung
2015-12-01
The first straight-wire appliance was introduced over 40 years ago to increase the consistency and efficiency of orthodontic treatment. More recently, computer-aided design and computer-aided manufacturing (CAD/CAM) technology has been used to create individualized orthodontic appliances. The purpose of this study was to investigate the clinical effectiveness and efficiency of CAD/CAM customized orthodontic appliances compared with direct and indirect bonded stock orthodontic brackets. This retrospective study included 3 treatment groups: group 1 patients were direct bonded with self-ligating appliances, group 2 patients were indirect bonded with self-ligating appliances, and group 3 patients were indirect bonded with CAD/CAM self-ligating appliances. Complete pretreatment and posttreatment records were obtained for all patients. The American Board of Orthodontics (ABO) Discrepancy Index was used to evaluate the pretreatment records, and the posttreatment outcomes were analyzed using the ABO Cast-Radiograph Evaluation. All data collection and analysis were completed by 1 evaluator. There were no statistically significant differences in the ABO Discrepancy Index or the ABO Cast-Radiograph Evaluation among the groups. Treatment times for the 3 groups were significantly different; the CAD/CAM group was the shortest at 13.8 ± 3.4 months, compared with 21.9 ± 5.0 and 16.9 ± 4.1 months for the direct bonded and indirect bonded groups, respectively. The number of treatment appointments for the CAD/CAM group was significantly fewer than for the direct bonded group. The CAD/CAM orthodontic bracket system evaluated in this study was as effective in treatment outcome measures as were standard brackets bonded both directly and indirectly. The CAD/CAM appliance was more efficient in regard to treatment duration, although the decrease in total archwire appointments was minimal. Further investigation is needed to better quantify the clinical benefits of CAD/CAM orthodontic appliances. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
de França, Danilo Gonzaga; Morais, Maria Helena; das Neves, Flávio D; Carreiro, Adriana Fonte; Barbosa, Gustavo As
The aim of this study was to evaluate the effectiveness of fabrication methods (computer-aided design/computer-aided manufacture [CAD/CAM], copy-milling, and conventional casting) in the fit accuracy of three-unit, screw-retained fixed dental prostheses. Sixteen three-unit implant-supported screw-retained frameworks were fabricated to fit an in vitro model. Eight frameworks were fabricated using the CAD/CAM system, four in zirconia and four in cobalt-chromium. Four zirconia frameworks were fabricated using the copy-milled system, and four were cast in cobalt-chromium using conventional casting with premachined abutments. The vertical and horizontal misfit at the implant-framework interface was measured using scanning electron microscopy at ×250. The results for vertical misfit were analyzed using Kruskal-Wallis and Mann-Whitney tests. The horizontal misfits were categorized as underextended, equally extended, or overextended. Statistical analysis established differences between groups according to the chi-square test (α = .05). The mean vertical misfit was 5.9 ± 3.6 μm for CAD/CAM-fabricated zirconia, 1.2 ± 2.2 μm for CAD/CAM-fabricated cobalt-chromium frameworks, 7.6 ± 9.2 μm for copy-milling-fabricated zirconia frameworks, and 11.8 (9.8) μm for conventionally fabricated frameworks. The Mann-Whitney test revealed significant differences between all but the zirconia-fabricated frameworks. A significant association was observed between the horizontal misfits and the fabrication method. The percentage of horizontal misfits that were underextended and overextended was higher in milled zirconia (83.3%), CAD/CAM cobaltchromium (66.7%), cast cobalt-chromium (58.3%), and CAD/CAM zirconia (33.3%) frameworks. CAD/CAM-fabricated frameworks exhibit better vertical misfit and low variability compared with copy-milled and conventionally fabricated frameworks. The percentage of interfaces equally extended was higher when CAD/CAM and zirconia were used.
Computer modeling of occlusal surfaces of posterior teeth with the CICERO CAD/CAM system.
Olthoff, L W; Van Der Zel, J M; De Ruiter, W J; Vlaar, S T; Bosman, F
2000-08-01
Static and dynamic occlusal interference frequently needs to be corrected by selective grinding of the occlusal surface of conventional cast and ceramic-fused-to-metal restorations. CAD/CAM techniques allow control of the dimensional contours of these restorations. However, parameters responsible for the occlusal form need to be determined. In most articulators, these parameters are set as default values. Which technique is best for minimizing the introduction of occlusal interference in restorations has not been determined. This study investigated differences in crown structure of a crown designed in static occlusion (STA) with designs adapted for dynamic occlusal interferences. Therefore, values from an optoelectronic registration system (String-Condylocomp, KAVO), an occlusal generated path (OGP) technique and default settings (DEF) were used in the CICERO CAD/CAM system. Morphology of CON, DEF, and OGP crowns was compared with that of the STA crown with respect to differences in a buccolingual section and frequency of occlusal distances in an interocclusal range of 1 mm, measured from the occlusal surface of the crown. All crown types fulfilled the esthetic and morphologic criteria for restorations in clinical dentistry. Difference in the morphology of the OGP crown, compared with that of the STA crown, was greater than that for the CON and DEF crowns. These differences were seen especially in the distobuccal part of the occlusal surface; however, the number of occlusal contacts was considered sufficient to stabilize occlusion. Functional occlusion, adapted to dynamic occlusion in a CICERO crown for the first mandibular molar, can be obtained using data acquired with the String-Condylocomp registration system. The OGP technique was preferred to other techniques because of the simplicity of the technique for eliminating potential problems with opposing teeth during motion. However, this is achieved at the cost of fewer points of contact during occlusion than with the CON crown.
Computerized breast cancer analysis system using three stage semi-supervised learning method.
Sun, Wenqing; Tseng, Tzu-Liang Bill; Zhang, Jianying; Qian, Wei
2016-10-01
A large number of labeled medical image data is usually a requirement to train a well-performed computer-aided detection (CAD) system. But the process of data labeling is time consuming, and potential ethical and logistical problems may also present complications. As a result, incorporating unlabeled data into CAD system can be a feasible way to combat these obstacles. In this study we developed a three stage semi-supervised learning (SSL) scheme that combines a small amount of labeled data and larger amount of unlabeled data. The scheme was modified on our existing CAD system using the following three stages: data weighing, feature selection, and newly proposed dividing co-training data labeling algorithm. Global density asymmetry features were incorporated to the feature pool to reduce the false positive rate. Area under the curve (AUC) and accuracy were computed using 10 fold cross validation method to evaluate the performance of our CAD system. The image dataset includes mammograms from 400 women who underwent routine screening examinations, and each pair contains either two cranio-caudal (CC) or two mediolateral-oblique (MLO) view mammograms from the right and the left breasts. From these mammograms 512 regions were extracted and used in this study, and among them 90 regions were treated as labeled while the rest were treated as unlabeled. Using our proposed scheme, the highest AUC observed in our research was 0.841, which included the 90 labeled data and all the unlabeled data. It was 7.4% higher than using labeled data only. With the increasing amount of labeled data, AUC difference between using mixed data and using labeled data only reached its peak when the amount of labeled data was around 60. This study demonstrated that our proposed three stage semi-supervised learning can improve the CAD performance by incorporating unlabeled data. Using unlabeled data is promising in computerized cancer research and may have a significant impact for future CAD system applications. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Comparison between five CAD/CAM systems for fit of zirconia copings.
Habib, Syed Rashid; Al Otaibi, Asim Khaled; Al Anazi, Talal Ali; Al Anazi, Samer Mosleh
2018-01-01
The aim of this in-vitro study was to investigate the marginal and internal fit of zirconia copings fabricated by five CAD/CAM (computer-aided design/computer-assisted manufacture) systems. A typodont mandibular right first molar was prepared according to ideal parameters for a zirconia crown, scanned digitally, and 100 identical resin dies fabricated by 3D printing. Samples were randomly divided into five groups and sent to CAD/CAM systems for zirconia copings (A, Ceramill-Motion 2, Amann Girrbach; B, Weiland, Ivoclar Vivadent; C, Cerec, Ivoclar Vivadent; D, Prettau Zirconia, Zirkonzahn; E, Cad4dent). CAD of the copings included standardized cement space of 30 µm and CAM was carried out. Copings were tried/adjusted on the respective dies and embedded under a standardized load of 20 N in self-curing resin. Samples were sectioned mesiodistally into two halves. Marginal and internal gap values were measured with a digital microscope at 50 to 200 × magnification at nine sites. The lowest and highest mean gap values of 46.93 ± 13.50 and 101.65 ± 35.56 μm were found for Group A and Group D, respectively. ANOVA showed a statistically significant difference between the mean values of all the groups (P = .000). Multiple comparisons with post hoc Tukey test indicated a statistically significant difference (P < .05) between: Group A and all groups except B; B with D; C with A; D with A; and B and E with A. Mean buccal/lingual gap value was found to be 51.54 ± 58.54 μm. Of the nine sites, the least gap resulted at the buccal axial wall and the greatest at the central groove. The overall mean gap recorded for the copings was 72.43 ± 57.56 μm. Marginal and internal adaptations of CAD/CAM zirconia copings is influenced by manufacturing technique, and variations exist for different systems. Measurement sites showed different levels. CAD/CAM systems investigated showed a clinically acceptable level of gap values (< 120 µm).
Performance evaluation of NASA/KSC CAD/CAE graphics local area network
NASA Technical Reports Server (NTRS)
Zobrist, George
1988-01-01
This study had as an objective the performance evaluation of the existing CAD/CAE graphics network at NASA/KSC. This evaluation will also aid in projecting planned expansions, such as the Space Station project on the existing CAD/CAE network. The objectives were achieved by collecting packet traffic on the various integrated sub-networks. This included items, such as total number of packets on the various subnetworks, source/destination of packets, percent utilization of network capacity, peak traffic rates, and packet size distribution. The NASA/KSC LAN was stressed to determine the useable bandwidth of the Ethernet network and an average design station workload was used to project the increased traffic on the existing network and the planned T1 link. This performance evaluation of the network will aid the NASA/KSC network managers in planning for the integration of future workload requirements into the existing network.
Jiang, Yutao; Hascall, Daniel; Li, Delia; Pease, Joseph H
2015-09-11
In this paper, we introduce a high throughput LCMS/UV/CAD/CLND system that improves upon previously reported systems by increasing both the quantitation accuracy and the range of compounds amenable to testing, in particular, low molecular weight "fragment" compounds. This system consists of a charged aerosol detector (CAD) and chemiluminescent nitrogen detector (CLND) added to a LCMS/UV system. Our results show that the addition of CAD and CLND to LCMS/UV is more reliable for concentration determination for a wider range of compounds than either detector alone. Our setup also allows for the parallel analysis of each sample by all four detectors and so does not significantly increase run time per sample. Copyright © 2015 Elsevier B.V. All rights reserved.
DeviceEditor visual biological CAD canvas
2012-01-01
Background Biological Computer Aided Design (bioCAD) assists the de novo design and selection of existing genetic components to achieve a desired biological activity, as part of an integrated design-build-test cycle. To meet the emerging needs of Synthetic Biology, bioCAD tools must address the increasing prevalence of combinatorial library design, design rule specification, and scar-less multi-part DNA assembly. Results We report the development and deployment of web-based bioCAD software, DeviceEditor, which provides a graphical design environment that mimics the intuitive visual whiteboard design process practiced in biological laboratories. The key innovations of DeviceEditor include visual combinatorial library design, direct integration with scar-less multi-part DNA assembly design automation, and a graphical user interface for the creation and modification of design specification rules. We demonstrate how biological designs are rendered on the DeviceEditor canvas, and we present effective visualizations of genetic component ordering and combinatorial variations within complex designs. Conclusions DeviceEditor liberates researchers from DNA base-pair manipulation, and enables users to create successful prototypes using standardized, functional, and visual abstractions. Open and documented software interfaces support further integration of DeviceEditor with other bioCAD tools and software platforms. DeviceEditor saves researcher time and institutional resources through correct-by-construction design, the automation of tedious tasks, design reuse, and the minimization of DNA assembly costs. PMID:22373390
NASA Astrophysics Data System (ADS)
Wormanns, Dag; Fiebich, Martin; Wietholt, Christian; Diederich, Stefan; Heindel, Walter
2000-06-01
We evaluated the practical application of a Computer-Aided Diagnosis (CAD) system for viewing spiral computed tomography (CT) of the chest low-dose screening examinations which includes an automatic detection of pulmonary nodules. A UNIX- based CAD system was developed including a detection algorithm for pulmonary nodules and a user interface providing an original axial image, the same image with nodules highlighted, a thin-slab MIP, and a cine mode. As yet, 26 CT examinations with 1625 images were reviewed in a clinical setting and reported by an experienced radiologist using both the CAD system and hardcopies. The CT studies exhibited 19 nodules found on the hardcopies in consensus reporting of 2 experienced radiologists. Viewing with the CAD system was more time consuming than using hardcopies (4.16 vs. 2.92 min) due to analyzing MIP and cine mode. The algorithm detected 49% (18/37) pulmonary nodules larger than 5 mm and 30% (21/70) of all nodules. It produced an average of 6.3 false positive findings per CT study. Most of the missed nodules were adjacent to the pleura. However, the program detected 6 nodules missed by the radiologists. Automatic nodule detection increases the radiologists's awareness of pulmonary lesions. Simultaneous display of axial image and thin-slab MIP makes the radiologist more confident in diagnosis of smaller pulmonary nodules. The CAD system improves the detection of pulmonary nodules at spiral CT. Lack of sensitivity and specificity is still an issue to be addressed but does not prevent practical use.
Defense AT&L (Volume 36, Number 5, September-October 2007)
2007-10-01
requirements, providing security solutions, and manag- ing the security of information systems. 14 CAD/ PAD Require- ments Determination in the Air Force...be contacted at williams_peter@bah.com and steward_tiffani@bah.com. Defense AT&L: September-October 2007 14 Williams is director of the CAD/ PAD Joint...the U.S. House Science and Technology Subcommittee on Transportation, Aviation and Materials. Blair is the former head of the Air Force CAD/ PAD
Overview of NASA MSFC IEC Multi-CAD Collaboration Capability
NASA Technical Reports Server (NTRS)
Moushon, Brian; McDuffee, Patrick
2005-01-01
This viewgraph presentation provides an overview of a Design and Data Management System (DDMS) for Computer Aided Design (CAD) collaboration in order to support the Integrated Engineering Capability (IEC) at Marshall Space Flight Center (MSFC).
Role of System Architecture in Architecture in Developing New Drafting Tools
NASA Astrophysics Data System (ADS)
Sorguç, Arzu Gönenç
In this study, the impact of information technologies in architectural design process is discussed. In this discussion, first the differences/nuances between the concept of software engineering and system architecture are clarified. Then, the design process in engineering, and design process in architecture has been compared by considering 3-D models as the center of design process over which the other disciplines involve the design. It is pointed out that in many high-end engineering applications, 3-D solid models and consequently digital mock-up concept has become a common practice. But, architecture as one of the important customers of CAD systems employing these tools has not started to use these 3-D models. It is shown that the reason of this time lag between architecture and engineering lies behind the tradition of design attitude. Therefore, it is proposed a new design scheme a meta-model to develop an integrated design model being centered on 3-D model. It is also proposed a system architecture to achieve the transformation of architectural design process by replacing 2-D thinking with 3-D thinking. It is stated that in the proposed system architecture, the CAD systems are included and adapted for 3-D architectural design in order to provide interfaces for integration of all possible disciplines to design process. It is also shown that such a change will allow to elaborate the intelligent or smart building concept in future.
Video display engineering and optimization system
NASA Technical Reports Server (NTRS)
Larimer, James (Inventor)
1997-01-01
A video display engineering and optimization CAD simulation system for designing a LCD display integrates models of a display device circuit, electro-optics, surface geometry, and physiological optics to model the system performance of a display. This CAD system permits system performance and design trade-offs to be evaluated without constructing a physical prototype of the device. The systems includes a series of modules which permit analysis of design trade-offs in terms of their visual impact on a viewer looking at a display.
Development of Cad System for Diffuse Disease Based on Ultrasound Elasticity Images
NASA Astrophysics Data System (ADS)
Yamazaki, M.; Shiina, T.; Yamakawa, M.; Takizawa, H.; Tonomura, A.; Mitake, T.
It is well known that as hepatic cirrhosis progresses, hepatocyte fibrosis spreads and nodule increases. However, it is not easy to diagnosis its early stage by conventional B-mode image because we have to read subtle change of speckle pattern which is not sensitive to the stage of fibrosis. Ultrasonic tissue elasticity imaging can provide us novel diagnostic information based on tissue hardness. We recently developed commercial-based equipment for tissue elasticity imaging. In this work, we investigated to develop the CAD system based on elasticity image for diagnosing defused type diseases such as hepatic cirrhosis. The results of clinical data analysis indicate that the CAD system is promising as means for diagnosis of diffuse disease with simple criterion.
Wauters, Lauri D J; Miguel-Moragas, Joan San; Mommaerts, Maurice Y
2015-11-01
To gain insight into the methodology of different computer-aided design-computer-aided manufacturing (CAD-CAM) applications for the reconstruction of cranio-maxillo-facial (CMF) defects. We reviewed and analyzed the available literature pertaining to CAD-CAM for use in CMF reconstruction. We proposed a classification system of the techniques of implant and cutting, drilling, and/or guiding template design and manufacturing. The system consisted of 4 classes (I-IV). These classes combine techniques used for both the implant and template to most accurately describe the methodology used. Our classification system can be widely applied. It should facilitate communication and immediate understanding of the methodology of CAD-CAM applications for the reconstruction of CMF defects.
Shimizu, Sakura; Shinya, Akikazu; Kuroda, Soichi; Gomi, Harunori
2017-07-26
The accuracy of prostheses affects clinical success and is, in turn, affected by the accuracy of the scanner and CAD programs. Thus, their accuracy is important. The first aim of this study was to evaluate the accuracy of an intraoral scanner with active triangulation (Cerec Omnicam), an intraoral scanner with a confocal laser (3Shape Trios), and an extraoral scanner with active triangulation (D810). The second aim of this study was to compare the accuracy of the digital crowns designed with two different scanner/CAD combinations. The accuracy of the intraoral scanners and extraoral scanner was clinically acceptable. Marginal and internal fit of the digital crowns fabricated using the intraoral scanner and CAD programs were inferior to those fabricated using the extraoral scanner and CAD programs.
Khomri, Bilal; Christodoulidis, Argyrios; Djerou, Leila; Babahenini, Mohamed Chaouki; Cheriet, Farida
2018-05-01
Retinal vessel segmentation plays an important role in the diagnosis of eye diseases and is considered as one of the most challenging tasks in computer-aided diagnosis (CAD) systems. The main goal of this study was to propose a method for blood-vessel segmentation that could deal with the problem of detecting vessels of varying diameters in high- and low-resolution fundus images. We proposed to use the particle swarm optimization (PSO) algorithm to improve the multiscale line detection (MSLD) method. The PSO algorithm was applied to find the best arrangement of scales in the MSLD method and to handle the problem of multiscale response recombination. The performance of the proposed method was evaluated on two low-resolution (DRIVE and STARE) and one high-resolution fundus (HRF) image datasets. The data include healthy (H) and diabetic retinopathy (DR) cases. The proposed approach improved the sensitivity rate against the MSLD by 4.7% for the DRIVE dataset and by 1.8% for the STARE dataset. For the high-resolution dataset, the proposed approach achieved 87.09% sensitivity rate, whereas the MSLD method achieves 82.58% sensitivity rate at the same specificity level. When only the smallest vessels were considered, the proposed approach improved the sensitivity rate by 11.02% and by 4.42% for the healthy and the diabetic cases, respectively. Integrating the proposed method in a comprehensive CAD system for DR screening would allow the reduction of false positives due to missed small vessels, misclassified as red lesions. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).
Zimmermann, Moritz; Valcanaia, Andre; Neiva, Gisele; Mehl, Albert; Fasbinder, Dennis
2018-03-06
A wide variety of CAD/CAM materials are available for single-tooth restorations. CAD/CAM material characteristics are different and may influence CAM fabrication accuracy. There is no study investigating the influence of different CAD/CAM materials on the final fit of the restoration. The aim of this study was to evaluate the fit of endocrowns fabricated from different CAD/CAM materials using a new 3D evaluation method with an intraoral scanning system. The null hypothesis was that there are no significant differences for the fitting accuracy of different CAD/CAM materials. Preparation for an endocrown was performed on a maxillary right first molar on a typodont, and restorations were fabricated with a chairside CAD/CAM system (CEREC Omnicam, MCXL). Three groups using three different CAD/CAM materials were established (each n = 10): zirconia-reinforced lithium silicate ceramic (Celtra Duo; CD), leucite-reinforced silicate ceramic (Empress CAD; EM), resin nanoceramic (Lava Ultimate; LU). A 3D digital measurement technique (OraCheck, Cyfex AG) using an intraoral scanner (CEREC Omnicam) was used to measure the difference in fit between the three materials for a master endocrown preparation. The preparation scan and the endocrown fit scan were matched with special difference analysis software OraCheck. Three areas were selected for fitting accuracy measurements: margin (MA), axial (AX), occlusal (OC). Statistical analysis was performed using 80% percentile, one-way ANOVA, and post-hoc Scheffé test. Significance level was set to p = 0.05. Results varied from best 88.9 ± 7.7 μm for marginal fit of resin nanoceramic restorations (LU_MA) to worst 182.3 ± 24.0 μm for occlusal fit of zirconia-reinforced lithium silicate restorations (CD_OC). Statistically significant differences were found both within and among the test groups. Group CD performed statistically significantly different from group LU for marginal fit (MA) and axial fit (AX) (p < 0.05). For occlusal fit (OC), no statistically significant differences were found within all three test groups (p > 0.05). Deviation pattern for differences was visually analyzed with a color-coded scheme for each restoration. Statistically significant differences were found for different CAD/CAM materials if the CAM procedure was identical. Within the limitations of this study, the choice of CAD/CAM material may influence the fitting accuracy of CAD/CAM-fabricated restorations. © 2018 by the American College of Prosthodontists.
CATO: a CAD tool for intelligent design of optical networks and interconnects
NASA Astrophysics Data System (ADS)
Chlamtac, Imrich; Ciesielski, Maciej; Fumagalli, Andrea F.; Ruszczyk, Chester; Wedzinga, Gosse
1997-10-01
Increasing communication speed requirements have created a great interest in very high speed optical and all-optical networks and interconnects. The design of these optical systems is a highly complex task, requiring the simultaneous optimization of various parts of the system, ranging from optical components' characteristics to access protocol techniques. Currently there are no computer aided design (CAD) tools on the market to support the interrelated design of all parts of optical communication systems, thus the designer has to rely on costly and time consuming testbed evaluations. The objective of the CATO (CAD tool for optical networks and interconnects) project is to develop a prototype of an intelligent CAD tool for the specification, design, simulation and optimization of optical communication networks. CATO allows the user to build an abstract, possible incomplete, model of the system, and determine its expected performance. Based on design constraints provided by the user, CATO will automatically complete an optimum design, using mathematical programming techniques, intelligent search methods and artificial intelligence (AI). Initial design and testing of a CATO prototype (CATO-1) has been completed recently. The objective was to prove the feasibility of combining AI techniques, simulation techniques, an optical device library and a graphical user interface into a flexible CAD tool for obtaining optimal communication network designs in terms of system cost and performance. CATO-1 is an experimental tool for designing packet-switching wavelength division multiplexing all-optical communication systems using a LAN/MAN ring topology as the underlying network. The two specific AI algorithms incorporated are simulated annealing and a genetic algorithm. CATO-1 finds the optimal number of transceivers for each network node, using an objective function that includes the cost of the devices and the overall system performance.
Ghafoorian, Mohsen; Karssemeijer, Nico; Heskes, Tom; Bergkamp, Mayra; Wissink, Joost; Obels, Jiri; Keizer, Karlijn; de Leeuw, Frank-Erik; Ginneken, Bram van; Marchiori, Elena; Platel, Bram
2017-01-01
Lacunes of presumed vascular origin (lacunes) are associated with an increased risk of stroke, gait impairment, and dementia and are a primary imaging feature of the small vessel disease. Quantification of lacunes may be of great importance to elucidate the mechanisms behind neuro-degenerative disorders and is recommended as part of study standards for small vessel disease research. However, due to the different appearance of lacunes in various brain regions and the existence of other similar-looking structures, such as perivascular spaces, manual annotation is a difficult, elaborative and subjective task, which can potentially be greatly improved by reliable and consistent computer-aided detection (CAD) routines. In this paper, we propose an automated two-stage method using deep convolutional neural networks (CNN). We show that this method has good performance and can considerably benefit readers. We first use a fully convolutional neural network to detect initial candidates. In the second step, we employ a 3D CNN as a false positive reduction tool. As the location information is important to the analysis of candidate structures, we further equip the network with contextual information using multi-scale analysis and integration of explicit location features. We trained, validated and tested our networks on a large dataset of 1075 cases obtained from two different studies. Subsequently, we conducted an observer study with four trained observers and compared our method with them using a free-response operating characteristic analysis. Shown on a test set of 111 cases, the resulting CAD system exhibits performance similar to the trained human observers and achieves a sensitivity of 0.974 with 0.13 false positives per slice. A feasibility study also showed that a trained human observer would considerably benefit once aided by the CAD system.
Khodaei, Banafsheh; Saeedi, Hassan; Jalali, Maryam; Farzadi, Maede; Norouzi, Ehsan
2017-12-01
The effect of foot orthoses on plantar pressure distribution has been proven by researchers but there are some controversies about advantages of custom-made foot orthoses to less expensive prefabricated foot orthoses. Nineteen flatfeet adults between 18 and 45 participated in this study. CAD-CAM foot orthoses were made for these patients according to their foot scan. Prefabricated foot orthoses were prepared according to their foot size. Plantar pressure, force and contact area were measured using pedar ® -x in-shoe system wearing shoe alone, wearing CAD-CAM foot orthoses and wearing prefabricated foot orthoses. Repeated measures ANOVA model with post-hoc, Bonferroni comparison were used to test differences. CAD-CAM and prefabricated foot orthoses both decreased pressure and force under 2nd, 3-5 metatarsal and heel regions comparing to shoe alone condition. CAD-CAM foot orthosis increased pressure under lateral toe region in comparison to shoe alone and prefabricated foot orthosis. Both foot orthoses increased pressure and contact area in medial midfoot region comparing to shoe alone condition. Increased forces were seen at hallux and lateral toes by prefabricated foot orthoses in comparison with CAD-CAM foot orthoses and control condition, respectively. According to the results, both foot orthoses could decrease the pressure under heel and metatarsal area. It seems that the special design of CAD-CAM foot orthoses could not make great differences in plantar pressure distribution in this sample. Further research is required to determine whether these results are associated with different scan systems or design software. Copyright © 2017 Elsevier Ltd. All rights reserved.
Nejatidanesh, Farahnaz; Shakibamehr, Amir Hossein; Savabi, Omid
2016-02-01
To evaluate the accuracy of marginal and internal adaptation of 2 computer-aided design/computer-aided manufacturing (CAD/CAM) and 2 conventionally made cement retained implant-supported restorations. An abutment and its corresponding fixture analog (Astra Tech) were inserted in left central incisor area of a maxillary cast. Four types of implant-supported single restorations were fabricated on the abutment (n = 10): e.max CAD (Cerec AC system), zirconia-based (Cercon system), IPS e.max Press, and metal-ceramic restorations. The internal and marginal gaps of the studied groups were measured by replica method and stereomicroscope. Data were subjected to 1-way ANOVA and Scheffe post hoc tests (α = 0.05). Mean internal gaps of Cercon (59.48 ± 16.49 μm) and e.max Press (75.62 ± 26.92 μm) groups were significantly different from e.max CAD (120.29 ± 16.74 μm) group, but there was no significant difference between metal-ceramic restorations (89.65 ± 47.84 μm) and e.max CAD. The marginal gaps of e.max CAD (32.02 ± 10.38 μm) and Cercon restorations (34.26 ± 11.41 μm) were significantly superior from metal ceramics (59.19 ± 17.81 μm) and e.max press (74.99 ± 24.51 μm). Within the limitations of this study, it can be concluded that although the marginal and internal gaps of the studied implant-supported restorations were in the clinically acceptable range, single crowns made with CAD/CAM technology provide better marginal fit.
Evaluation of Shipbuilding CAD/CAM/CIM Systems - Phase II (Requirements for Future Systems)
1997-02-01
INNOVATION MARINE INDUSTRY STANDARDS WELDING INDUSTRIAL ENGINEERING EDUCATION AND TRAINING THE NATIONAL SHIPBUILDING RESEARCH PROGRAM February 1997 NSRP 0479...an analysis of CAD/CAM/CIM in shipyards, ship-design software firms, and alIied industries in Europe, Japan and the U.S. The purpose of the analysis...possible: Black and Veatch Hitachi Ariake Works Industrial Technology Institute Intergraph Corporation Kockums Computer Systems Mitsubishi Heavy Industries
Gidron, Yori; Kupper, Nina; Kwaijtaal, Martijn; Winter, Jobst; Denollet, Johan
2007-12-01
The current understanding of the pathophysiology of atherosclerosis leading to coronary artery disease (CAD) emphasizes the role of inflammatory mediators. Given the bidirectional communication between the immune and central nervous systems, an important question is whether the brain can be "informed" about and modulate CAD-related inflammation. A candidate communicator and modulator is the vagus nerve. Until now, the vagus nerve has received attention in cardiology mainly due to its role in the parasympathetic cardiovascular response. However, the vagus nerve can also "inform" the brain about peripheral inflammation since its paraganglia have receptors for interleukin-1. Furthermore, its efferent branch has a local anti-inflammatory effect. These effects have not been considered in research on the vagus nerve in CAD or in vagus nerve stimulation trials in CAD. In addition, various behavioural interventions, including relaxation, may influence CAD prognosis by affecting vagal activity. Based on this converging evidence, we propose a neuroimmunomodulation approach to atherogenesis. In this model, the vagus nerve "informs" the brain about CAD-related cytokines; in turn, activation of the vagus (via vagus nerve stimulation, vagomimetic drugs or relaxation) induces an anti-inflammatory response that can slow down the chronic process of atherogenesis.
Hua, Kai-Lung; Hsu, Che-Hao; Hidayati, Shintami Chusnul; Cheng, Wen-Huang; Chen, Yu-Jen
2015-01-01
Lung cancer has a poor prognosis when not diagnosed early and unresectable lesions are present. The management of small lung nodules noted on computed tomography scan is controversial due to uncertain tumor characteristics. A conventional computer-aided diagnosis (CAD) scheme requires several image processing and pattern recognition steps to accomplish a quantitative tumor differentiation result. In such an ad hoc image analysis pipeline, every step depends heavily on the performance of the previous step. Accordingly, tuning of classification performance in a conventional CAD scheme is very complicated and arduous. Deep learning techniques, on the other hand, have the intrinsic advantage of an automatic exploitation feature and tuning of performance in a seamless fashion. In this study, we attempted to simplify the image analysis pipeline of conventional CAD with deep learning techniques. Specifically, we introduced models of a deep belief network and a convolutional neural network in the context of nodule classification in computed tomography images. Two baseline methods with feature computing steps were implemented for comparison. The experimental results suggest that deep learning methods could achieve better discriminative results and hold promise in the CAD application domain. PMID:26346558
Ciocca, Leonardo; Donati, Davide; Fantini, Massimiliano; Landi, Elena; Piattelli, Adriano; Iezzi, Giovanna; Tampieri, Anna; Spadari, Alessandro; Romagnoli, Noemi; Scotti, Roberto
2013-08-01
In this study, rapid CAD-CAM prototyping of pure hydroxyapatite to replace temporomandibular joint condyles was tested in sheep. Three adult animals were implanted with CAD-CAM-designed porous hydroxyapatite scaffolds as condyle substitutes. The desired scaffold shape was achieved by subtractive automated milling machining (block reduction). Custom-made surgical guides were created by direct metal laser sintering and were used to export the virtual planning of the bone cut lines into the surgical environment. Using the same technique, fixation plates were created and applied to the scaffold pre-operatively to firmly secure the condyles to the bone and to assure primary stability of the hydroxyapatite scaffolds during masticatory function. Four months post-surgery, the sheep were sacrificed. The hydroxyapatite scaffolds were explanted, and histological specimens were prepared. Different histological tissues penetrating the scaffold macropores, the sequence of bone remodeling, new apposition of bone and/or cartilage as a consequence of the different functional anatomic role, and osseointegration at the interface between the scaffold and bone were documented. This animal model was found to be appropriate for testing CAD-CAM customization and the biomechanical properties of porous, pure hydroxyapatite scaffolds used as joint prostheses.
Hua, Kai-Lung; Hsu, Che-Hao; Hidayati, Shintami Chusnul; Cheng, Wen-Huang; Chen, Yu-Jen
2015-01-01
Lung cancer has a poor prognosis when not diagnosed early and unresectable lesions are present. The management of small lung nodules noted on computed tomography scan is controversial due to uncertain tumor characteristics. A conventional computer-aided diagnosis (CAD) scheme requires several image processing and pattern recognition steps to accomplish a quantitative tumor differentiation result. In such an ad hoc image analysis pipeline, every step depends heavily on the performance of the previous step. Accordingly, tuning of classification performance in a conventional CAD scheme is very complicated and arduous. Deep learning techniques, on the other hand, have the intrinsic advantage of an automatic exploitation feature and tuning of performance in a seamless fashion. In this study, we attempted to simplify the image analysis pipeline of conventional CAD with deep learning techniques. Specifically, we introduced models of a deep belief network and a convolutional neural network in the context of nodule classification in computed tomography images. Two baseline methods with feature computing steps were implemented for comparison. The experimental results suggest that deep learning methods could achieve better discriminative results and hold promise in the CAD application domain.
In Silico Syndrome Prediction for Coronary Artery Disease in Traditional Chinese Medicine
Lu, Peng; Chen, Jianxin; Zhao, Huihui; Gao, Yibo; Luo, Liangtao; Zuo, Xiaohan; Shi, Qi; Yang, Yiping; Yi, Jianqiang; Wang, Wei
2012-01-01
Coronary artery disease (CAD) is the leading causes of deaths in the world. The differentiation of syndrome (ZHENG) is the criterion of diagnosis and therapeutic in TCM. Therefore, syndrome prediction in silico can be improving the performance of treatment. In this paper, we present a Bayesian network framework to construct a high-confidence syndrome predictor based on the optimum subset, that is, collected by Support Vector Machine (SVM) feature selection. Syndrome of CAD can be divided into asthenia and sthenia syndromes. According to the hierarchical characteristics of syndrome, we firstly label every case three types of syndrome (asthenia, sthenia, or both) to solve several syndromes with some patients. On basis of the three syndromes' classes, we design SVM feature selection to achieve the optimum symptom subset and compare this subset with Markov blanket feature select using ROC. Using this subset, the six predictors of CAD's syndrome are constructed by the Bayesian network technique. We also design Naïve Bayes, C4.5 Logistic, Radial basis function (RBF) network compared with Bayesian network. In a conclusion, the Bayesian network method based on the optimum symptoms shows a practical method to predict six syndromes of CAD in TCM. PMID:22567030
Liu, Xiao; Shi, Jun; Zhou, Shichong; Lu, Minhua
2014-01-01
The dimensionality reduction is an important step in ultrasound image based computer-aided diagnosis (CAD) for breast cancer. A newly proposed l2,1 regularized correntropy algorithm for robust feature selection (CRFS) has achieved good performance for noise corrupted data. Therefore, it has the potential to reduce the dimensions of ultrasound image features. However, in clinical practice, the collection of labeled instances is usually expensive and time costing, while it is relatively easy to acquire the unlabeled or undetermined instances. Therefore, the semi-supervised learning is very suitable for clinical CAD. The iterated Laplacian regularization (Iter-LR) is a new regularization method, which has been proved to outperform the traditional graph Laplacian regularization in semi-supervised classification and ranking. In this study, to augment the classification accuracy of the breast ultrasound CAD based on texture feature, we propose an Iter-LR-based semi-supervised CRFS (Iter-LR-CRFS) algorithm, and then apply it to reduce the feature dimensions of ultrasound images for breast CAD. We compared the Iter-LR-CRFS with LR-CRFS, original supervised CRFS, and principal component analysis. The experimental results indicate that the proposed Iter-LR-CRFS significantly outperforms all other algorithms.
2010-04-01
glycoproteins of Zaire ebolavirus (ZEBOV) and Sudan ebolavirus (SEBOV) in a single complex adenovirus -based vector (CAdVax). We evaluated our vaccine ...recombinant complex adenovirus vaccine (CAdVax) system, which provides multivalent protection of NHPs against multiple species of filoviruses (33). The...CAdVax vaccine platform is based on a complex, replication-defective adenovirus 5 (Ad5) vector (28–30, 37, 38) that allows for the incorporation of
A SINDA thermal model using CAD/CAE technologies
NASA Technical Reports Server (NTRS)
Rodriguez, Jose A.; Spencer, Steve
1992-01-01
The approach to thermal analysis described by this paper is a technique that incorporates Computer Aided Design (CAD) and Computer Aided Engineering (CAE) to develop a thermal model that has the advantages of Finite Element Methods (FEM) without abandoning the unique advantages of Finite Difference Methods (FDM) in the analysis of thermal systems. The incorporation of existing CAD geometry, the powerful use of a pre and post processor and the ability to do interdisciplinary analysis, will be described.
Tourassi, Georgia D; Harrawood, Brian; Singh, Swatee; Lo, Joseph Y; Floyd, Carey E
2007-01-01
The purpose of this study was to evaluate image similarity measures employed in an information-theoretic computer-assisted detection (IT-CAD) scheme. The scheme was developed for content-based retrieval and detection of masses in screening mammograms. The study is aimed toward an interactive clinical paradigm where physicians query the proposed IT-CAD scheme on mammographic locations that are either visually suspicious or indicated as suspicious by other cuing CAD systems. The IT-CAD scheme provides an evidence-based, second opinion for query mammographic locations using a knowledge database of mass and normal cases. In this study, eight entropy-based similarity measures were compared with respect to retrieval precision and detection accuracy using a database of 1820 mammographic regions of interest. The IT-CAD scheme was then validated on a separate database for false positive reduction of progressively more challenging visual cues generated by an existing, in-house mass detection system. The study showed that the image similarity measures fall into one of two categories; one category is better suited to the retrieval of semantically similar cases while the second is more effective with knowledge-based decisions regarding the presence of a true mass in the query location. In addition, the IT-CAD scheme yielded a substantial reduction in false-positive detections while maintaining high detection rate for malignant masses.
Effect of Home Bleaching on the Translucency of CAD/CAM Systems.
Karci, Muhammet; Demir, Necla
2017-11-10
To evaluate the effect of a home bleaching agent (Opalescence PF) on the translucency of CAD/CAM ceramic systems. The 28 sintered ceramic specimens (IPS Empress CAD and IPS e.max CAD; 15 mm long, 10 mm wide, 1 mm thick) were divided into two subgroups as control and bleaching groups (n = 7). Carbamide peroxide (CP), 16%, home bleaching agent was applied onto the surface of each specimen for 6 hours per day for 7 days. A spectrophotometer (VITA Easyshade Advance) was used to measure the CIE L * a * b * coordinates and the reflectance value (Y) of the specimens on white and black backgrounds. The translucency parameter (TP), contrast ratio (CR), and opalescence parameter (OP) of the specimens were calculated. The data were statistically analyzed using Kolmogorov-Smirnov, one-way ANOVA, Tukey's test, and Pearson's correlation. Statistically significant differences in the TP values after 16% CP bleaching treatment were observed (p ˂ 0.05); however, no significant differences were found in the OP and CR values after the surface treatment (p ˃ 0.05). According to our study, patients who have all-ceramic restorations in their mouths should be careful when using home bleaching agents, because whitening agents can affect the translucency of all-ceramic restorations such as e.max CAD and Empress CAD. © 2017 by the American College of Prosthodontists.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tourassi, Georgia D.; Harrawood, Brian; Singh, Swatee
The purpose of this study was to evaluate image similarity measures employed in an information-theoretic computer-assisted detection (IT-CAD) scheme. The scheme was developed for content-based retrieval and detection of masses in screening mammograms. The study is aimed toward an interactive clinical paradigm where physicians query the proposed IT-CAD scheme on mammographic locations that are either visually suspicious or indicated as suspicious by other cuing CAD systems. The IT-CAD scheme provides an evidence-based, second opinion for query mammographic locations using a knowledge database of mass and normal cases. In this study, eight entropy-based similarity measures were compared with respect to retrievalmore » precision and detection accuracy using a database of 1820 mammographic regions of interest. The IT-CAD scheme was then validated on a separate database for false positive reduction of progressively more challenging visual cues generated by an existing, in-house mass detection system. The study showed that the image similarity measures fall into one of two categories; one category is better suited to the retrieval of semantically similar cases while the second is more effective with knowledge-based decisions regarding the presence of a true mass in the query location. In addition, the IT-CAD scheme yielded a substantial reduction in false-positive detections while maintaining high detection rate for malignant masses.« less
NASA Technical Reports Server (NTRS)
Haimes, Robert; Follen, Gregory J.
1998-01-01
CAPRI is a CAD-vendor neutral application programming interface designed for the construction of analysis and design systems. By allowing access to the geometry from within all modules (grid generators, solvers and post-processors) such tasks as meshing on the actual surfaces, node enrichment by solvers and defining which mesh faces are boundaries (for the solver and visualization system) become simpler. The overall reliance on file 'standards' is minimized. This 'Geometry Centric' approach makes multi-physics (multi-disciplinary) analysis codes much easier to build. By using the shared (coupled) surface as the foundation, CAPRI provides a single call to interpolate grid-node based data from the surface discretization in one volume to another. Finally, design systems are possible where the results can be brought back into the CAD system (and therefore manufactured) because all geometry construction and modification are performed using the CAD system's geometry kernel.
CAD Integration : new optical design possibilities
NASA Astrophysics Data System (ADS)
Haumonte, Jean-Baptiste; Venturino, Jean-Claude
2005-09-01
The development of optical design and analysis tools in a CAD software can help to optimise the design, size and performance of tomorrow's consumer products. While optics was still held back by software limitations, CAD programs were moving forward in leaps and bounds, improving manufacturing technologies and making it possible to design and produce highly innovative and sophisticated products. The problem was that in the past, 'traditional' optical design programs were only able to simulate spherical and aspherical lenses, meaning that the optical designers were limited to designing systems which were a series of imperfect lenses, each one correcting the last. That is why OPTIS has created the first optical design program to be fully integrated into a CAD program. The technology is available from OPTIS in an integrated SOLIDWORKS or CATIA V5 version. Users of this software can reduce the number of lenses needed in a system. Designers will now have access to complex surfaces such as NURBS meaning they will now be able to define free shape progressive lenses and even improve on optical performances using fewer lenses. This revolutionary technology will allow mechanical designers to work on optical systems and to share information with optical designers for the first time. Previously not possible in a CAD program you may now determine all the optical performances of any optical system, providing first order and third order performances, sequential and non-sequential ray-tracing, wavefront surfaces, point spread function, MTF, spot-diagram, using real optical surfaces and guaranteeing the mechanical precision necessary for an optical system.
Telfer, Scott; Gibson, Kellie S; Hennessy, Kym; Steultjens, Martijn P; Woodburn, Jim
2012-05-01
To determine, for a number of techniques used to obtain foot shape based around plaster casting, foam box impressions, and 3-dimensional scanning, (1) the effect the technique has on the overall reproducibility of custom foot orthoses (FOs) in terms of inter- and intracaster reliability and (2) the reproducibility of FO design by using computer-aided design (CAD) software in terms of inter- and intra-CAD operator reliability for all these techniques. Cross-sectional study. University laboratory. Convenience sample of individuals (N=22) with noncavus foot types. Not applicable. Parameters of the FO design (length, width at forefoot, width at rearfoot, and peak medial arch height), the forefoot to rearfoot angle of the foot shape, and overall volume match between device designs. For intra- and intercaster reliability of the different methods of obtaining the foot shape, all methods fell below the reproducibility quality threshold for the medial arch height of the device, and volume matching was <80% for all methods. The more experienced CAD operator was able to achieve excellent reliability (intraclass correlation coefficients >0.75) for all variables with the exception of forefoot to rearfoot angle, with overall volume matches of >87% of the devices. None of the techniques for obtaining foot shape met all the criteria for excellent reproducibility, with the peak arch height being particularly variable. Additional variability is added at the CAD stage of the FO design process, although with adequate operator experience good to excellent reproducibility may be achieved at this stage. Taking only basic linear or angular measurement parameters from the device may fail to fully capture the variability in FO design. Copyright © 2012 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Lima, Tiago; Carvalho, Ágata; Carvalho, Vasco
2012-01-01
ABSTRACT Objectives The aim of this study was to assess the clinical outcomes achieved with Computer-Assisted Design/Computer-Assisted Manufacturing implant abutments in the anterior maxilla. Material and Methods Nineteen patients with a mean age of 41 (range form 26 to 63) years, treated with 21 single tooth implants and 21 Computer-Assisted Design/Computer-Assisted Manufacturing (CAD/CAM) abutments in the anterior maxillary region were included in this study. The patients followed 4 criteria of inclusion: (1) had a single-tooth implant in the anterior maxilla, (2) had a CAD/CAM abutment, (3) had a contralateral natural tooth, (4) the implant was restored and in function for at least 6 months up to 2 years. Cases without contact point were excluded. Presence/absence of the interproximal papilla, inter tooth-implant distance (ITD) and distance from the base of the contact point to dental crest bone of adjacent tooth (CPB) were accessed. Results Forty interproximal spaces were evaluated, with an average mesial CPB of 5.65 (SD 1.65) mm and distal CPB of 4.65 (SD 1.98) mm. An average mesial ITD of 2.49 (SD 0.69) mm and an average distal ITD of 1.89 (SD 0.63) mm were achieved. Papilla was present in all the interproximal spaces accessed. Conclusions The restoration of dental implants using CAD/CAM abutments is a predictable treatment with improved aesthetic results. These type of abutments seem to help maintaining a regular papillary filling although the variations of the implant positioning or the restoration teeth relation. PMID:24422016
Automatic Generation of CFD-Ready Surface Triangulations from CAD Geometry
NASA Technical Reports Server (NTRS)
Aftosmis, M. J.; Delanaye, M.; Haimes, R.; Nixon, David (Technical Monitor)
1998-01-01
This paper presents an approach for the generation of closed manifold surface triangulations from CAD geometry. CAD parts and assemblies are used in their native format, without translation, and a part's native geometry engine is accessed through a modeler-independent application programming interface (API). In seeking a robust and fully automated procedure, the algorithm is based on a new physical space manifold triangulation technique which was developed to avoid robustness issues associated with poorly conditioned mappings. In addition, this approach avoids the usual ambiguities associated with floating-point predicate evaluation on constructed coordinate geometry in a mapped space, The technique is incremental, so that each new site improves the triangulation by some well defined quality measure. Sites are inserted using a variety of priority queues to ensure that new insertions will address the worst triangles first, As a result of this strategy, the algorithm will return its 'best' mesh for a given (prespecified) number of sites. Alternatively, the algorithm may be allowed to terminate naturally after achieving a prespecified measure of mesh quality. The resulting triangulations are 'CFD-ready' in that: (1) Edges match the underlying part model to within a specified tolerance. (2) Triangles on disjoint surfaces in close proximity have matching length-scales. (3) The algorithm produces a triangulation such that no angle is less than a given angle bound, alpha, or greater than Pi - 2alpha This result also sets bounds on the maximum vertex degree, triangle aspect-ratio and maximum stretching rate for the triangulation. In addition to tile output triangulations for a variety of CAD parts, tile discussion presents related theoretical results which assert the existence of such all angle bound, and demonstrate that maximum bounds of between 25 deg and 30 deg may be achieved in practice.
Gunasekaran, Prasad; Jeevanantham, Vinodh; Sharma, Suresh; Thapa, Rashmi; Gupta, Kamal
Cholesterol management guidelines from the American College of Cardiology/American Heart Association (ACC/AHA-2013) recommend fixed statin dosing (dose depends on age ≤ or >75years) compared to the earlier adult treatment panel III (ATPIII) guidelines which recommended specific low-density lipoprotein-cholesterol (LDL-C) targets. Clinical implications of this recommendation are not known. We retrospectively compared cholesterol levels and statin utilization across cohorts with coronary artery disease (CAD) (n=9563), peripheral arterial disease (PAD) (n=596) and CAD+PAD (n=975) by applying both guidelines. The percentage of patients who achieved guideline-specific targets using 2013 ACC/AHA (use of moderate/high intensity statins) or ATPIII guidelines (LDL-C<100mg/dl) was compared between all groups. Using both guidelines, the PAD only group demonstrated lower utilization and lower statin doses than the CAD or CAD+PAD groups. When applying the ACC/AHA guidelines, more patients in the CAD only group (age ≤75 years) were considered at goal as compared to the ATPIII guidelines (92.2% vs. 75%), primarily driven by the group placed on moderate/high intensity statins but had an LDL-C level >100mg/dl. Application of the ACC/AHA guidelines results in a higher percentage of patients considered to be 'at goal' when compared to the ATP III guidelines without changes in clinical practice. This is due to patients ≤75 years old on adequate statin doses but still have LDL-C levels >100mg/dl, thereby raising concerns that physicians may not pursue alternate LDL reduction strategies since they are now considered at goal despite LDL-C >100mg/dl. Lipid management of PAD patients remains sub-optimal as compared to CAD and CAD+PAD. Copyright © 2017. Published by Elsevier B.V.
Single High Fidelity Geometric Data Sets for LCM - Model Requirements
2006-11-01
are extensive single 3D CAD data models incorporating hull structure, propulsion, steering, piping , electrical, HVAC and other systems, which make...single 3D CAD data models incorporating hull structure, propulsion, steering, piping , electrical, HVAC and other systems. During this same period...be sufficiently flexible to accommodate the diverse requirements of various types of structural analyses. Section Properties & Material Data
Fabricating CAD/CAM Implant-Retained Mandibular Bar Overdentures: A Clinical and Technical Overview.
Goo, Chui Ling; Tan, Keson Beng Choon
2017-01-01
This report describes the clinical and technical aspects in the oral rehabilitation of an edentulous patient with knife-edge ridge at the mandibular anterior edentulous region, using implant-retained overdentures. The application of computer-aided design and computer-aided manufacturing (CAD/CAM) in the fabrication of the overdenture framework simplifies the laboratory process of the implant prostheses. The Nobel Procera CAD/CAM System was utilised to produce a lightweight titanium overdenture bar with locator attachments. It is proposed that the digital workflow of CAD/CAM milled implant overdenture bar allows us to avoid numerous technical steps and possibility of casting errors involved in the conventional casting of such bars.
CAD-Based Shielding Analysis for ITER Port Diagnostics
NASA Astrophysics Data System (ADS)
Serikov, Arkady; Fischer, Ulrich; Anthoine, David; Bertalot, Luciano; De Bock, Maartin; O'Connor, Richard; Juarez, Rafael; Krasilnikov, Vitaly
2017-09-01
Radiation shielding analysis conducted in support of design development of the contemporary diagnostic systems integrated inside the ITER ports is relied on the use of CAD models. This paper presents the CAD-based MCNP Monte Carlo radiation transport and activation analyses for the Diagnostic Upper and Equatorial Port Plugs (UPP #3 and EPP #8, #17). The creation process of the complicated 3D MCNP models of the diagnostics systems was substantially accelerated by application of the CAD-to-MCNP converter programs MCAM and McCad. High performance computing resources of the Helios supercomputer allowed to speed-up the MCNP parallel transport calculations with the MPI/OpenMP interface. The found shielding solutions could be universal, reducing ports R&D costs. The shield block behind the Tritium and Deposit Monitor (TDM) optical box was added to study its influence on Shut-Down Dose Rate (SDDR) in Port Interspace (PI) of EPP#17. Influence of neutron streaming along the Lost Alpha Monitor (LAM) on the neutron energy spectra calculated in the Tangential Neutron Spectrometer (TNS) of EPP#8. For the UPP#3 with Charge eXchange Recombination Spectroscopy (CXRS-core), an excessive neutron streaming along the CXRS shutter, which should be prevented in further design iteration.
Precision of a CAD/CAM technique for the production of zirconium dioxide copings.
Coli, Pierluigi; Karlsson, Stig
2004-01-01
The precision of a computer-aided design/manufacturing (CAD/CAM) system to manufacture zirconium dioxide copings with a predetermined internal space was investigated. Two master models were produced in acrylic resin. One was directly scanned by the Decim Reader. The Decim Producer then manufactured 10 copings from prefabricated zirconium dioxide blocks. Five copings were prepared, aiming for an internal space to the master of 45 microm. The other five copings were prepared for an internal space of 90 microm. The second test model was used to try in the copings produced. The obtained internal space of the ceramic copings was evaluated by separate measurements of the master models and inner surfaces of the copings. The master models were measured at predetermined points with an optical instrument. The zirconium dioxide copings were measured with a contact instrument at the corresponding sites measured in the masters. The first group of copings had a mean internal space to the scanned master of 41 microm and of 53 microm to the try-in master. In general, the internal space along the axial walls of the masters was smaller than that along the occlusal walls. The second group had a mean internal space of 82 microm to the scanned master and of 90 microm to the try-in master. The aimed-for internal space of the copings was achieved by the manufacturer. The CAD/CAM technique tested provided high precision in the manufacture of zirconium dioxide copings.
Advanced computer-aided design for bone tissue-engineering scaffolds.
Ramin, E; Harris, R A
2009-04-01
The design of scaffolds with an intricate and controlled internal structure represents a challenge for tissue engineering. Several scaffold-manufacturing techniques allow the creation of complex architectures but with little or no control over the main features of the channel network such as the size, shape, and interconnectivity of each individual channel, resulting in intricate but random structures. The combined use of computer-aided design (CAD) systems and layer-manufacturing techniques allows a high degree of control over these parameters with few limitations in terms of achievable complexity. However, the design of complex and intricate networks of channels required in CAD is extremely time-consuming since manually modelling hundreds of different geometrical elements, all with different parameters, may require several days to design individual scaffold structures. An automated design methodology is proposed by this research to overcome these limitations. This approach involves the investigation of novel software algorithms, which are able to interact with a conventional CAD program and permit the automated design of several geometrical elements, each with a different size and shape. In this work, the variability of the parameters required to define each geometry has been set as random, but any other distribution could have been adopted. This methodology has been used to design five cubic scaffolds with interconnected pore channels that range from 200 to 800 microm in diameter, each with an increased complexity of the internal geometrical arrangement. A clinical case study, consisting of an integration of one of these geometries with a craniofacial implant, is then presented.
NASA Astrophysics Data System (ADS)
Qiu, Yuchen; Tan, Maxine; McMeekin, Scott; Thai, Theresa; Moore, Kathleen; Ding, Kai; Liu, Hong; Zheng, Bin
2015-03-01
The purpose of this study is to identify and apply quantitative image biomarkers for early prediction of the tumor response to the chemotherapy among the ovarian cancer patients participated in the clinical trials of testing new drugs. In the experiment, we retrospectively selected 30 cases from the patients who participated in Phase I clinical trials of new drug or drug agents for ovarian cancer treatment. Each case is composed of two sets of CT images acquired pre- and post-treatment (4-6 weeks after starting treatment). A computer-aided detection (CAD) scheme was developed to extract and analyze the quantitative image features of the metastatic tumors previously tracked by the radiologists using the standard Response Evaluation Criteria in Solid Tumors (RECIST) guideline. The CAD scheme first segmented 3-D tumor volumes from the background using a hybrid tumor segmentation scheme. Then, for each segmented tumor, CAD computed three quantitative image features including the change of tumor volume, tumor CT number (density) and density variance. The feature changes were calculated between the matched tumors tracked on the CT images acquired pre- and post-treatments. Finally, CAD predicted patient's 6-month progression-free survival (PFS) using a decision-tree based classifier. The performance of the CAD scheme was compared with the RECIST category. The result shows that the CAD scheme achieved a prediction accuracy of 76.7% (23/30 cases) with a Kappa coefficient of 0.493, which is significantly higher than the performance of RECIST prediction with a prediction accuracy and Kappa coefficient of 60% (17/30) and 0.062, respectively. This study demonstrated the feasibility of analyzing quantitative image features to improve the early predicting accuracy of the tumor response to the new testing drugs or therapeutic methods for the ovarian cancer patients.
Mazzoni, Simona; Bianchi, Alberto; Schiariti, Giulio; Badiali, Giovanni; Marchetti, Claudio
2015-04-01
The purpose of the present study was to develop a computer-aided design (CAD) and computer-aided manufacturing (CAM) technique that enabled fabrication of surgical cutting guides and titanium fixation plates that would allow the upper maxilla to be repositioned correctly without a surgical splint in orthognathic patients. Ten patients were recruited. A complete CAD-CAM workflow for orthognathic surgery has 3 steps: 1) virtual planning of the surgical treatment, 2) CAD-CAM and 3-dimensional printing of customized surgical devices (surgical cutting guide and titanium fixation plates), and 3) computer-aided surgery. Upper maxilla repositioning was performed in a waferless manner using a CAD-CAM device: the surgical cutting guide was used during surgery to pilot the osteotomy line that had been planned preoperatively at the computer and the custom-made fixation titanium plates allowed desired repositioning of the maxilla. To evaluate the reproducibility of this CAD-CAM orthognathic surgical method, the virtually planned and actually achieved positions of the upper maxilla were compared. Overlap errors using a threshold value smaller than 2 mm were evaluated, and the frequency of such errors was used as a measurement of accuracy. By this definition, the accuracy was 100% in 7 patients (range in all patients, 62 to 100%; median, 92.7%). These results tend to confirm that the use of CAD-CAM cutting guides and customized titanium plates for upper maxilla repositioning represents a promising method for the accurate reproduction of preoperative virtual planning without the use of surgical splints. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Kleber, M E; Goliasch, G; Grammer, T B; Pilz, S; Tomaschitz, A; Silbernagel, G; Maurer, G; März, W; Niessner, A
2014-08-01
Algorithms to predict the future long-term risk of patients with stable coronary artery disease (CAD) are rare. The VIenna and Ludwigshafen CAD (VILCAD) risk score was one of the first scores specifically tailored for this clinically important patient population. The aim of this study was to refine risk prediction in stable CAD creating a new prediction model encompassing various pathophysiological pathways. Therefore, we assessed the predictive power of 135 novel biomarkers for long-term mortality in patients with stable CAD. We included 1275 patients with stable CAD from the LUdwigshafen RIsk and Cardiovascular health study with a median follow-up of 9.8 years to investigate whether the predictive power of the VILCAD score could be improved by the addition of novel biomarkers. Additional biomarkers were selected in a bootstrapping procedure based on Cox regression to determine the most informative predictors of mortality. The final multivariable model encompassed nine clinical and biochemical markers: age, sex, left ventricular ejection fraction (LVEF), heart rate, N-terminal pro-brain natriuretic peptide, cystatin C, renin, 25OH-vitamin D3 and haemoglobin A1c. The extended VILCAD biomarker score achieved a significantly improved C-statistic (0.78 vs. 0.73; P = 0.035) and net reclassification index (14.9%; P < 0.001) compared to the original VILCAD score. Omitting LVEF, which might not be readily measureable in clinical practice, slightly reduced the accuracy of the new BIO-VILCAD score but still significantly improved risk classification (net reclassification improvement 12.5%; P < 0.001). The VILCAD biomarker score based on routine parameters complemented by novel biomarkers outperforms previous risk algorithms and allows more accurate classification of patients with stable CAD, enabling physicians to choose more personalized treatment regimens for their patients.
Acharya, U Rajendra; Sree, S Vinitha; Krishnan, M Muthu Rama; Molinari, Filippo; Zieleźnik, Witold; Bardales, Ricardo H; Witkowska, Agnieszka; Suri, Jasjit S
2014-02-01
Computer-aided diagnostic (CAD) techniques aid physicians in better diagnosis of diseases by extracting objective and accurate diagnostic information from medical data. Hashimoto thyroiditis is the most common type of inflammation of the thyroid gland. The inflammation changes the structure of the thyroid tissue, and these changes are reflected as echogenic changes on ultrasound images. In this work, we propose a novel CAD system (a class of systems called ThyroScan) that extracts textural features from a thyroid sonogram and uses them to aid in the detection of Hashimoto thyroiditis. In this paradigm, we extracted grayscale features based on stationary wavelet transform from 232 normal and 294 Hashimoto thyroiditis-affected thyroid ultrasound images obtained from a Polish population. Significant features were selected using a Student t test. The resulting feature vectors were used to build and evaluate the following 4 classifiers using a 10-fold stratified cross-validation technique: support vector machine, decision tree, fuzzy classifier, and K-nearest neighbor. Using 7 significant features that characterized the textural changes in the images, the fuzzy classifier had the highest classification accuracy of 84.6%, sensitivity of 82.8%, specificity of 87.0%, and a positive predictive value of 88.9%. The proposed ThyroScan CAD system uses novel features to noninvasively detect the presence of Hashimoto thyroiditis on ultrasound images. Compared to manual interpretations of ultrasound images, the CAD system offers a more objective interpretation of the nature of the thyroid. The preliminary results presented in this work indicate the possibility of using such a CAD system in a clinical setting after evaluating it with larger databases in multicenter clinical trials.
Management of CAD/CAM information: Key to improved manufacturing productivity
NASA Technical Reports Server (NTRS)
Fulton, R. E.; Brainin, J.
1984-01-01
A key element to improved industry productivity is effective management of CAD/CAM information. To stimulate advancements in this area, a joint NASA/Navy/Industry project designated Integrated Programs for Aerospace-Vehicle Design (IPAD) is underway with the goal of raising aerospace industry productivity through advancement of technology to integrate and manage information involved in the design and manufacturing process. The project complements traditional NASA/DOD research to develop aerospace design technology and the Air Force's Integrated Computer-Aided Manufacturing (ICAM) program to advance CAM technology. IPAD research is guided by an Industry Technical Advisory Board (ITAB) composed of over 100 repesentatives from aerospace and computer companies. The IPAD accomplishments to date in development of requirements and prototype software for various levels of company-wide CAD/CAM data management are summarized and plans for development of technology for management of distributed CAD/CAM data and information required to control future knowledge-based CAD/CAM systems are discussed.
rCAD: A Novel Database Schema for the Comparative Analysis of RNA.
Ozer, Stuart; Doshi, Kishore J; Xu, Weijia; Gutell, Robin R
2011-12-31
Beyond its direct involvement in protein synthesis with mRNA, tRNA, and rRNA, RNA is now being appreciated for its significance in the overall metabolism and regulation of the cell. Comparative analysis has been very effective in the identification and characterization of RNA molecules, including the accurate prediction of their secondary structure. We are developing an integrative scalable data management and analysis system, the RNA Comparative Analysis Database (rCAD), implemented with SQL Server to support RNA comparative analysis. The platformagnostic database schema of rCAD captures the essential relationships between the different dimensions of information for RNA comparative analysis datasets. The rCAD implementation enables a variety of comparative analysis manipulations with multiple integrated data dimensions for advanced RNA comparative analysis workflows. In this paper, we describe details of the rCAD schema design and illustrate its usefulness with two usage scenarios.
rCAD: A Novel Database Schema for the Comparative Analysis of RNA
Ozer, Stuart; Doshi, Kishore J.; Xu, Weijia; Gutell, Robin R.
2013-01-01
Beyond its direct involvement in protein synthesis with mRNA, tRNA, and rRNA, RNA is now being appreciated for its significance in the overall metabolism and regulation of the cell. Comparative analysis has been very effective in the identification and characterization of RNA molecules, including the accurate prediction of their secondary structure. We are developing an integrative scalable data management and analysis system, the RNA Comparative Analysis Database (rCAD), implemented with SQL Server to support RNA comparative analysis. The platformagnostic database schema of rCAD captures the essential relationships between the different dimensions of information for RNA comparative analysis datasets. The rCAD implementation enables a variety of comparative analysis manipulations with multiple integrated data dimensions for advanced RNA comparative analysis workflows. In this paper, we describe details of the rCAD schema design and illustrate its usefulness with two usage scenarios. PMID:24772454
Tapie, L; Lebon, N; Mawussi, B; Fron Chabouis, H; Duret, F; Attal, J-P
2015-01-01
As digital technology infiltrates every area of daily life, including the field of medicine, so it is increasingly being introduced into dental practice. Apart from chairside practice, computer-aided design/computer-aided manufacturing (CAD/CAM) solutions are available for creating inlays, crowns, fixed partial dentures (FPDs), implant abutments, and other dental prostheses. CAD/CAM dental solutions can be considered a chain of digital devices and software for the almost automatic design and creation of dental restorations. However, dentists who want to use the technology often do not have the time or knowledge to understand it. A basic knowledge of the CAD/CAM digital workflow for dental restorations can help dentists to grasp the technology and purchase a CAM/CAM system that meets the needs of their office. This article provides a computer-science and mechanical-engineering approach to the CAD/CAM digital workflow to help dentists understand the technology.
CAD Services: an Industry Standard Interface for Mechanical CAD Interoperability
NASA Technical Reports Server (NTRS)
Claus, Russell; Weitzer, Ilan
2002-01-01
Most organizations seek to design and develop new products in increasingly shorter time periods. At the same time, increased performance demands require a team-based multidisciplinary design process that may span several organizations. One approach to meet these demands is to use 'Geometry Centric' design. In this approach, design engineers team their efforts through one united representation of the design that is usually captured in a CAD system. Standards-based interfaces are critical to provide uniform, simple, distributed services that enable the 'Geometry Centric' design approach. This paper describes an industry-wide effort, under the Object Management Group's (OMG) Manufacturing Domain Task Force, to define interfaces that enable the interoperability of CAD, Computer Aided Manufacturing (CAM), and Computer Aided Engineering (CAE) tools. This critical link to enable 'Geometry Centric' design is called: Cad Services V1.0. This paper discusses the features of this standard and proposed application.
Computer-aided detection of brain metastasis on 3D MR imaging: Observer performance study.
Sunwoo, Leonard; Kim, Young Jae; Choi, Seung Hong; Kim, Kwang-Gi; Kang, Ji Hee; Kang, Yeonah; Bae, Yun Jung; Yoo, Roh-Eul; Kim, Jihang; Lee, Kyong Joon; Lee, Seung Hyun; Choi, Byung Se; Jung, Cheolkyu; Sohn, Chul-Ho; Kim, Jae Hyoung
2017-01-01
To assess the effect of computer-aided detection (CAD) of brain metastasis (BM) on radiologists' diagnostic performance in interpreting three-dimensional brain magnetic resonance (MR) imaging using follow-up imaging and consensus as the reference standard. The institutional review board approved this retrospective study. The study cohort consisted of 110 consecutive patients with BM and 30 patients without BM. The training data set included MR images of 80 patients with 450 BM nodules. The test set included MR images of 30 patients with 134 BM nodules and 30 patients without BM. We developed a CAD system for BM detection using template-matching and K-means clustering algorithms for candidate detection and an artificial neural network for false-positive reduction. Four reviewers (two neuroradiologists and two radiology residents) interpreted the test set images before and after the use of CAD in a sequential manner. The sensitivity, false positive (FP) per case, and reading time were analyzed. A jackknife free-response receiver operating characteristic (JAFROC) method was used to determine the improvement in the diagnostic accuracy. The sensitivity of CAD was 87.3% with an FP per case of 302.4. CAD significantly improved the diagnostic performance of the four reviewers with a figure-of-merit (FOM) of 0.874 (without CAD) vs. 0.898 (with CAD) according to JAFROC analysis (p < 0.01). Statistically significant improvement was noted only for less-experienced reviewers (FOM without vs. with CAD, 0.834 vs. 0.877, p < 0.01). The additional time required to review the CAD results was approximately 72 sec (40% of the total review time). CAD as a second reader helps radiologists improve their diagnostic performance in the detection of BM on MR imaging, particularly for less-experienced reviewers.
The effect of varying levels of vehicle automation on drivers' lane changing behaviour.
Madigan, Ruth; Louw, Tyron; Merat, Natasha
2018-01-01
Much of the Human Factors research into vehicle automation has focused on driver responses to critical scenarios where a crash might occur. However, there is less knowledge about the effects of vehicle automation on drivers' behaviour during non-critical take-over situations, such as driver-initiated lane-changing or overtaking. The current driving simulator study, conducted as part of the EC-funded AdaptIVe project, addresses this issue. It uses a within-subjects design to compare drivers' lane-changing behaviour in conventional manual driving, partially automated driving (PAD) and conditionally automated driving (CAD). In PAD, drivers were required to re-take control from an automated driving system in order to overtake a slow moving vehicle, while in CAD, the driver used the indicator lever to initiate a system-performed overtaking manoeuvre. Results showed that while drivers' acceptance of both the PAD and CAD systems was high, they generally preferred CAD. A comparison of overtaking positions showed that drivers initiated overtaking manoeuvres slightly later in PAD than in manual driving or CAD. In addition, when compared to conventional driving, drivers had higher deviations in lane positioning and speed, along with higher lateral accelerations during lane changes following PAD. These results indicate that even in situations which are not time-critical, drivers' vehicle control after automation is degraded compared to conventional driving.
The effect of varying levels of vehicle automation on drivers’ lane changing behaviour
Louw, Tyron; Merat, Natasha
2018-01-01
Much of the Human Factors research into vehicle automation has focused on driver responses to critical scenarios where a crash might occur. However, there is less knowledge about the effects of vehicle automation on drivers’ behaviour during non-critical take-over situations, such as driver-initiated lane-changing or overtaking. The current driving simulator study, conducted as part of the EC-funded AdaptIVe project, addresses this issue. It uses a within-subjects design to compare drivers’ lane-changing behaviour in conventional manual driving, partially automated driving (PAD) and conditionally automated driving (CAD). In PAD, drivers were required to re-take control from an automated driving system in order to overtake a slow moving vehicle, while in CAD, the driver used the indicator lever to initiate a system-performed overtaking manoeuvre. Results showed that while drivers’ acceptance of both the PAD and CAD systems was high, they generally preferred CAD. A comparison of overtaking positions showed that drivers initiated overtaking manoeuvres slightly later in PAD than in manual driving or CAD. In addition, when compared to conventional driving, drivers had higher deviations in lane positioning and speed, along with higher lateral accelerations during lane changes following PAD. These results indicate that even in situations which are not time-critical, drivers’ vehicle control after automation is degraded compared to conventional driving. PMID:29466402
[Coloration of mica glass ceramic for use in dental CAD/CAM system].
Sun, Ying; Wang, Zhong-yi; Tian, Jie-mo; Cao, Xiao-gang
2003-03-01
An intrinsically colored machinable glass-ceramic containing tetrasilicic fluormica as the predominant crystal phase was studied, which was used in molar crown in dental CAD/CAM system. Orthogonal design analysis was used to select appropriate base formula, coloration and heat treatment process. Factors influencing the color appearance of mica glass ceramic were nucleation agent and the ratio of Mg(2+) to K(+) in base formula; Cerium oxide (CeO(2)) was used as the main coloration; The preferred heat treatment was 650 degrees C for 1 h and 1,000 degrees C or 1,050 degrees C for 3 h - 4 h. This mica glass-ceramic could provide 4 to 5 color appearance for dental use, it showed excellent machinability which was eminently suitable for use in dental CAD/CAM system.
Impact of IPAD on CAD/CAM database university research
NASA Technical Reports Server (NTRS)
Leach, L. M.; Wozny, M. J.
1984-01-01
IPAD program has provided direction, focus and software products which impacted on CAD/CAM data base research and follow-on research. The relationship of IPAD to the research projects which involve the storage of geometric data in common data ase facilities such as data base machines, the exchange of data between heterogeneous data bases, the development of IGES processors, the migration of lrge CAD/CAM data base management systems to noncompatible hosts, and the value of RIM as a research tool is described.
Introduction and Highlights of the Workshop
NASA Technical Reports Server (NTRS)
Noor, Ahmed K.; Venneri, Samuel L.
1997-01-01
Four generations of CAD/CAM systems can be identified, corresponding to changes in both modeling functionality and software architecture. The systems evolved from 2D and wireframes to solid modeling, to parametric/variational modelers to the current simulation-embedded systems. Recent developments have enabled design engineers to perform many of the complex analysis tasks, typically performed by analysis experts. Some of the characteristics of the current and emerging CAD/CAM/CAE systems are described in subsequent presentations. The focus of the workshop is on the potential of CAD/CAM/CAE systems for use in simulating the entire mission and life-cycle of future aerospace systems, and the needed development to realize this potential. First, the major features of the emerging computing, communication and networking environment are outlined; second, the characteristics and design drivers of future aerospace systems are identified; third, the concept of intelligent synthesis environment being planned by NASA, the UVA ACT Center and JPL is presented; and fourth, the objectives and format of the workshop are outlined.
Increasing CAD system efficacy for lung texture analysis using a convolutional network
NASA Astrophysics Data System (ADS)
Tarando, Sebastian Roberto; Fetita, Catalin; Faccinetto, Alex; Brillet, Pierre-Yves
2016-03-01
The infiltrative lung diseases are a class of irreversible, non-neoplastic lung pathologies requiring regular follow-up with CT imaging. Quantifying the evolution of the patient status imposes the development of automated classification tools for lung texture. For the large majority of CAD systems, such classification relies on a two-dimensional analysis of axial CT images. In a previously developed CAD system, we proposed a fully-3D approach exploiting a multi-scale morphological analysis which showed good performance in detecting diseased areas, but with a major drawback consisting of sometimes overestimating the pathological areas and mixing different type of lung patterns. This paper proposes a combination of the existing CAD system with the classification outcome provided by a convolutional network, specifically tuned-up, in order to increase the specificity of the classification and the confidence to diagnosis. The advantage of using a deep learning approach is a better regularization of the classification output (because of a deeper insight into a given pathological class over a large series of samples) where the previous system is extra-sensitive due to the multi-scale response on patient-specific, localized patterns. In a preliminary evaluation, the combined approach was tested on a 10 patient database of various lung pathologies, showing a sharp increase of true detections.
3-D Human body models in C.A.D. : Anthropometric Aspects
NASA Astrophysics Data System (ADS)
Renaud, C.; Steck, R.; Pineau, J. C.
1986-07-01
Modeling and simulation methods of man-machine systems are developed at the laboratory by interactive infography and C.A.D. technics. In order to better apprehend the morphological variability of populations we have enriched the 3-D model with a parametric function using classical anthropometric dimensions. We have selected reference, associate and complementary dimensions : lengths, breadths, circumferences and depths, which depend on operator's tasks and characteristics of workplaces. All anthropometric values come from the International Data Bank of Human Biometry of ERGODATA System. The utilization of the parametric function brings a quick and accurate description of morphology for theoretic subjects and can be used in C.A.D. analysis.
NASA Astrophysics Data System (ADS)
Ness, P. H.; Jacobson, H.
1984-10-01
The thrust of 'group technology' is toward the exploitation of similarities in component design and manufacturing process plans to achieve assembly line flow cost efficiencies for small batch production. The systematic method devised for the identification of similarities in component geometry and processing steps is a coding and classification scheme implemented by interactive CAD/CAM systems. This coding and classification scheme has led to significant increases in computer processing power, allowing rapid searches and retrievals on the basis of a 30-digit code together with user-friendly computer graphics.
1984-01-01
working drawings, lists, and miscellaneous information needed for construction and testing (fig. 4). Detail design and construction in- cludes...still in test and evaluation phases, and is currently operational on a CDC computer. Its approach to management of geometric data is a unique and...been to provide the high degree of engineering user flexibility and yet achieve acceptable response times. In late 1983, a test system which has user
A survey on computer aided diagnosis for ocular diseases
2014-01-01
Background Computer Aided Diagnosis (CAD), which can automate the detection process for ocular diseases, has attracted extensive attention from clinicians and researchers alike. It not only alleviates the burden on the clinicians by providing objective opinion with valuable insights, but also offers early detection and easy access for patients. Method We review ocular CAD methodologies for various data types. For each data type, we investigate the databases and the algorithms to detect different ocular diseases. Their advantages and shortcomings are analyzed and discussed. Result We have studied three types of data (i.e., clinical, genetic and imaging) that have been commonly used in existing methods for CAD. The recent developments in methods used in CAD of ocular diseases (such as Diabetic Retinopathy, Glaucoma, Age-related Macular Degeneration and Pathological Myopia) are investigated and summarized comprehensively. Conclusion While CAD for ocular diseases has shown considerable progress over the past years, the clinical importance of fully automatic CAD systems which are able to embed clinical knowledge and integrate heterogeneous data sources still show great potential for future breakthrough. PMID:25175552
Keul, Christine; Müller-Hahl, Manuel; Eichberger, Marlis; Liebermann, Anja; Roos, Malgorzata; Edelhoff, Daniel; Stawarczyk, Bogna
2014-09-01
To determine the impact of pre-treatment of adhesive systems on the work of adhesion (WA) between CAD/CAM polymers and resin composite cements and compare with conventional tests of previous studies. Surface parameters were measured by contact angle measurement (2700 measurements) and WA was calculated. Five CAD/CAM polymers were used for fabrication of specimens (n=75/subgroup): artBloc Temp (A), Telio CAD (B), Nano Composite CFI-C (C), exp. CAD/CAM nanohybrid composite (D), and LAVA Ultimate (E). Then, air-abraded specimens were pre-treated (n=15 per group): Ambarino P60 (I), Monobond Plus/Heliobond (II), visio.link (III), VP connect (IV), and no pre-treatment (V). Resin composite cement specimens (n=75) were smoothed out homogeneously on a glass plate (n=15/group): RelyX ARC (RXA), Variolink II (VAR), Panavia F2.0 (PAN), RelyX Unicem (RXU), and Clearfil SA Cement (CSA). Contact angles were determined with 3 drops of distilled water and diiodomethane each. Data were analyzed using Kruskal-Wallis-H test and Spearman-Rho correlation (p<0.05). CAD/CAM materials (B), (A), and (C) showed higher WA compared to (D) and (E). (II) and (IV) resulted in higher WA than (I), (III) and (V). VAR had the significantly lowest WA, followed by RXU, RXA, CSA and PAN. No correlation occurred between WA and TBS/SBS whereas polar component of surface free energy of CAD/CAM resin and spreading coefficient showed significant positive correlation with TBS/SBS. Determination of WA is not a proper method to draw conclusions about the bond between resin materials. Destructive test methods are not dispensable. The successful outcome of fixed dental restorations depends, among others, on the quality of bonding between the tooth and the restoration. Additional pre-treatment of the dental CAD/CAM resin restoration by bonding systems can be recommended for clinical use. Pre-treatment showed a significant impact on the surface properties. Copyright © 2014 Elsevier Ltd. All rights reserved.
Mously, Hisham A; Finkelman, Matthew; Zandparsa, Roya; Hirayama, Hiroshi
2014-08-01
The accuracy of chairside computer-aided design and computer-aided manufacturing (CAD/CAM) restorations is questionable, and the effect of the die spacer settings is not well stated in the literature. The purpose of the study was to evaluate the marginal and internal adaptation of E4D crowns fabricated with different spacer thicknesses and to compare these crowns with those fabricated with the heat-press technique. The E4D system was used to fabricate 30 crowns for the first 3 groups, with different spacer thickness settings: 30 μm, 60 μm, and 100 μm. In the fourth group, 10 lithium disilicate crowns were fabricated with the heat-press technique. The occlusal gap, axial gap, vertical marginal gap, and absolute marginal discrepancy were evaluated by x-ray microtomography. Statistical significance was assessed with the Kruskal-Wallis test (α=.05). For post hoc analyses, the Mann-Whitney U test was used alongside the Bonferroni correction for multiple comparisons (α=.008). Within the CAD/CAM groups, the 30-μm spacer thickness resulted in the lowest median axial gap (90.04 μm), whereas the 60-μm spacer thickness resulted in the lowest median occlusal gap (152.39 μm). The median marginal gap values of the CAD/CAM-60 group (49.35 μm) and CAD/CAM-100 group (46.65 μm) were lower than those of the CAD/CAM-30 group (55.18 μm). No significant differences among the CAD/CAM groups were observed for absolute marginal discrepancy. The heat-press group had significantly different values than those of the CAD/CAM groups. The spacer thickness and fabrication technique affected the adaptation of ceramic crowns. The heat-press group yielded the best marginal and internal crown adaptation results. The 30- or 60-μm spacer settings are recommended for the E4D CAD/CAM system. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Kage, Andreas; Canto, Marcia; Gorospe, Emmanuel; Almario, Antonio; Münzenmayer, Christian
2010-03-01
In the near future, Computer Assisted Diagnosis (CAD) which is well known in the area of mammography might be used to support clinical experts in the diagnosis of images derived from imaging modalities such as endoscopy. In the recent past, a few first approaches for computer assisted endoscopy have been presented already. These systems use a video signal as an input that is provided by the endoscopes video processor. Despite the advent of high-definition systems most standard endoscopy systems today still provide only analog video signals. These signals consist of interlaced images that can not be used in a CAD approach without deinterlacing. Of course, there are many different deinterlacing approaches known today. But most of them are specializations of some basic approaches. In this paper we present four basic deinterlacing approaches. We have used a database of non-interlaced images which have been degraded by artificial interlacing and afterwards processed by these approaches. The database contains regions of interest (ROI) of clinical relevance for the diagnosis of abnormalities in the esophagus. We compared the classification rates on these ROIs on the original images and after the deinterlacing. The results show that the deinterlacing has an impact on the classification rates. The Bobbing approach and the Motion Compensation approach achieved the best classification results in most cases.
Huang, P J; Chieng, P U; Lee, Y T; Chiang, F T; Tseng, Y Z; Liau, C S; Tseng, C D; Su, C T; Lien, W P
1992-11-01
Exercise thallium-201 imaging using single-photon emission computed tomography (SPECT) was evaluated in 154 patients with angiographically documented coronary artery disease (CAD) and in 25 normal subjects. Of the 154 patients with CAD, 134 (87%) had abnormal thallium images. By contrast, only 77 (50%) patients had ischemic ST-segment depression (p < 0.001). Among 25 normal subjects, 20 had normal exercise SPECT images. The specificity of exercise SPECT imaging (80% or 20/25) in excluding patients with CAD was not significantly higher than that of exercise electrocardiography (76% or 19/25). For the detection of individual vessel involvement by analysis of territories of perfusion abnormalities, the sensitivity and specificity of exercise SPECT were 72% and 96% for the left anterior descending, 78% and 85% for the right coronary, and 47% and 98% for the left circumflex artery. Ninety (group 1) of the 154 patients with CAD achieved adequate exercise end points (ischemic ST-segment depression or > 85% of maximal predicted heart rate) and 64 (group 2) did not. Exercise SPECT showed significantly more perfusion abnormalities in group 1 than in group 2 (96% vs 75%, p < 0.001). We conclude that: (1) exercise SPECT thallium imaging is more sensitive than exercise electrocardiography for detecting patients with CAD; (2) the sensitivity of the test is affected by the level of exercise; and (3) it is valuable in the identification of individual vessel involvement.
Computer-aided diagnosis of liver tumors on computed tomography images.
Chang, Chin-Chen; Chen, Hong-Hao; Chang, Yeun-Chung; Yang, Ming-Yang; Lo, Chung-Ming; Ko, Wei-Chun; Lee, Yee-Fan; Liu, Kao-Lang; Chang, Ruey-Feng
2017-07-01
Liver cancer is the tenth most common cancer in the USA, and its incidence has been increasing for several decades. Early detection, diagnosis, and treatment of the disease are very important. Computed tomography (CT) is one of the most common and robust imaging techniques for the detection of liver cancer. CT scanners can provide multiple-phase sequential scans of the whole liver. In this study, we proposed a computer-aided diagnosis (CAD) system to diagnose liver cancer using the features of tumors obtained from multiphase CT images. A total of 71 histologically-proven liver tumors including 49 benign and 22 malignant lesions were evaluated with the proposed CAD system to evaluate its performance. Tumors were identified by the user and then segmented using a region growing algorithm. After tumor segmentation, three kinds of features were obtained for each tumor, including texture, shape, and kinetic curve. The texture was quantified using 3 dimensional (3-D) texture data of the tumor based on the grey level co-occurrence matrix (GLCM). Compactness, margin, and an elliptic model were used to describe the 3-D shape of the tumor. The kinetic curve was established from each phase of tumor and represented as variations in density between each phase. Backward elimination was used to select the best combination of features, and binary logistic regression analysis was used to classify the tumors with leave-one-out cross validation. The accuracy and sensitivity for the texture were 71.82% and 68.18%, respectively, which were better than for the shape and kinetic curve under closed specificity. Combining all of the features achieved the highest accuracy (58/71, 81.69%), sensitivity (18/22, 81.82%), and specificity (40/49, 81.63%). The Az value of combining all features was 0.8713. Combining texture, shape, and kinetic curve features may be able to differentiate benign from malignant tumors in the liver using our proposed CAD system. Copyright © 2017 Elsevier B.V. All rights reserved.
Creation of system of computer-aided design for technological objects
NASA Astrophysics Data System (ADS)
Zubkova, T. M.; Tokareva, M. A.; Sultanov, N. Z.
2018-05-01
Due to the competition in the market of process equipment, its production should be flexible, retuning to various product configurations, raw materials and productivity, depending on the current market needs. This process is not possible without CAD (computer-aided design). The formation of CAD begins with planning. Synthesizing, analyzing, evaluating, converting operations, as well as visualization and decision-making operations, can be automated. Based on formal description of the design procedures, the design route in the form of an oriented graph is constructed. The decomposition of the design process, represented by the formalized description of the design procedures, makes it possible to make an informed choice of the CAD component for the solution of the task. The object-oriented approach allows us to consider the CAD as an independent system whose properties are inherited from the components. The first step determines the range of tasks to be performed by the system, and a set of components for their implementation. The second one is the configuration of the selected components. The interaction between the selected components is carried out using the CALS standards. The chosen CAD / CAE-oriented approach allows creating a single model, which is stored in the database of the subject area. Each of the integration stages is implemented as a separate functional block. The transformation of the CAD model into the model of the internal representation is realized by the block of searching for the geometric parameters of the technological machine, in which the XML-model of the construction is obtained on the basis of the feature method from the theory of image recognition. The configuration of integrated components is divided into three consecutive steps: configuring tasks, components, interfaces. The configuration of the components is realized using the theory of "soft computations" using the Mamdani fuzzy inference algorithm.
Farahani, Navid; Liu, Zheng; Jutt, Dylan; Fine, Jeffrey L
2017-10-01
- Pathologists' computer-assisted diagnosis (pCAD) is a proposed framework for alleviating challenges through the automation of their routine sign-out work. Currently, hypothetical pCAD is based on a triad of advanced image analysis, deep integration with heterogeneous information systems, and a concrete understanding of traditional pathology workflow. Prototyping is an established method for designing complex new computer systems such as pCAD. - To describe, in detail, a prototype of pCAD for the sign-out of a breast cancer specimen. - Deidentified glass slides and data from breast cancer specimens were used. Slides were digitized into whole-slide images with an Aperio ScanScope XT, and screen captures were created by using vendor-provided software. The advanced workflow prototype was constructed by using PowerPoint software. - We modeled an interactive, computer-assisted workflow: pCAD previews whole-slide images in the context of integrated, disparate data and predefined diagnostic tasks and subtasks. Relevant regions of interest (ROIs) would be automatically identified and triaged by the computer. A pathologist's sign-out work would consist of an interactive review of important ROIs, driven by required diagnostic tasks. The interactive session would generate a pathology report automatically. - Using animations and real ROIs, the pCAD prototype demonstrates the hypothetical sign-out in a stepwise fashion, illustrating various interactions and explaining how steps can be automated. The file is publicly available and should be widely compatible. This mock-up is intended to spur discussion and to help usher in the next era of digitization for pathologists by providing desperately needed and long-awaited automation.
Kumar, K R V; Ranganath, V; Naik, R; Banu, S; Nichani, A S
2014-12-01
Various epidemiological studies have implied that local infection may increase the levels of systemic inflammatory mediators and lipid mediators, thereby promoting atherosclerosis. The aim of this study was to assess high-sensitivity C-reactive protein (HsCRP) and lipid levels in healthy adults and patients with coronary artery disease (CAD), with and without periodontitis. A total of 100 subjects were included in the study and categorized into four groups of 25 subjects each, as follows: subjects with chronic periodontitis with angiographically proven CAD; nonperiodontitis subjects with angiographically proven CAD; otherwise healthy subjects with only chronic periodontitis; and systemically and orally healthy individuals. The periodontal parameters measured included plaque index, gingival index, probing pocket depth, clinical attachment level and marginal alveolar bone loss (which was recorded radiographically). Serum samples were collected for estimation of HsCRP, low-density lipoprotein (LDL), high-density lipoprotein (HDL) and triglycerides (TGs). The serum HsCRP levels in subjects with either CAD or chronic periodontitis were elevated two-fold compared with those of healthy individuals, whereas in subjects with both diseases (CAD plus chronic periodontitis) the levels were elevated three-fold. The serum LDL level was higher, and the serum HDL level was lower, in all the test groups compared with the healthy group. No significant difference among the groups was detected in the TG levels. A persistent infection, such as chronic periodontitis, may influence changes in the systemic levels of HsCRP, LDL and HDL, which potentially have an impact on inflammation-associated atherosclerotic processes, such as CAD. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Ma, Kevin; Wong, Jonathan; Zhong, Mark; Zhang, Jeff; Liu, Brent
2014-03-01
In the past, we have presented an imaging-informatics based eFolder system for managing and analyzing imaging and lesion data of multiple sclerosis (MS) patients, which allows for data storage, data analysis, and data mining in clinical and research settings. The system integrates the patient's clinical data with imaging studies and a computer-aided detection (CAD) algorithm for quantifying MS lesion volume, lesion contour, locations, and sizes in brain MRI studies. For compliance with IHE integration protocols, long-term storage in PACS, and data query and display in a DICOM compliant clinical setting, CAD results need to be converted into DICOM-Structured Report (SR) format. Open-source dcmtk and customized XML templates are used to convert quantitative MS CAD results from MATLAB to DICOM-SR format. A web-based GUI based on our existing web-accessible DICOM object (WADO) image viewer has been designed to display the CAD results from generated SR files. The GUI is able to parse DICOM-SR files and extract SR document data, then display lesion volume, location, and brain matter volume along with the referenced DICOM imaging study. In addition, the GUI supports lesion contour overlay, which matches a detected MS lesion with its corresponding DICOM-SR data when a user selects either the lesion or the data. The methodology of converting CAD data in native MATLAB format to DICOM-SR and displaying the tabulated DICOM-SR along with the patient's clinical information, and relevant study images in the GUI will be demonstrated. The developed SR conversion model and GUI support aim to further demonstrate how to incorporate CAD post-processing components in a PACS and imaging informatics-based environment.
Modified Framingham Risk Factor Score for Systemic Lupus Erythematosus.
Urowitz, Murray B; Ibañez, Dominique; Su, Jiandong; Gladman, Dafna D
2016-05-01
The traditional Framingham Risk Factor Score (FRS) underestimates the risk for coronary artery disease (CAD) in patients with systemic lupus erythematosus (SLE). We aimed to determine whether an adjustment to the FRS would more accurately reflect the higher prevalence of CAD among patients with SLE. Patients with SLE without a previous history of CAD or diabetes followed regularly at the University of Toronto Lupus Clinic were included. A modified FRS (mFRS) was calculated by multiplying the items by 1.5, 2, 3, or 4. In the first part of the study, using one-third of all eligible patients, we evaluated the sensitivity and specificity of the FRS and the different multipliers for the mFRS. In the second part of the study, using the remaining 2/3 of the eligible patients, we compared the predictive ability of the FRS to the mFRS. In the third part of the study, we assessed the prediction for CAD in a time-dependent analysis of the FRS and mFRS. There were 905 women (89.3%) with a total of 95 CAD events included. In part 1, we determined that a multiplier of 2 provided the best combination of sensitivity and specificity. In part 2, 2.4% of the patients were classified as moderate/high risk based on the classic FRS and 17.3% using the 2FRS (the FRS with a multiplier of 2). In part 3, a time-dependent covariate analysis for the prediction of the first CAD event revealed an HR of 3.22 (p = 0.07) for the classic FRS and 4.37 (p < 0.0001) for the 2FRS. An mFRS in which each item is multiplied by 2 more accurately predicts CAD in patients with SLE.
2011-01-01
Background Single reading with computer aided detection (CAD) is an alternative to double reading for detecting cancer in screening mammograms. The aim of this study is to investigate whether the use of a single reader with CAD is more cost-effective than double reading. Methods Based on data from the CADET II study, the cost-effectiveness of single reading with CAD versus double reading was measured in terms of cost per cancer detected. Cost (Pound (£), year 2007/08) of single reading with CAD versus double reading was estimated assuming a health and social service perspective and a 7 year time horizon. As the equipment cost varies according to the unit size a separate analysis was conducted for high, average and low volume screening units. One-way sensitivity analyses were performed by varying the reading time, equipment and assessment cost, recall rate and reader qualification. Results CAD is cost increasing for all sizes of screening unit. The introduction of CAD is cost-increasing compared to double reading because the cost of CAD equipment, staff training and the higher assessment cost associated with CAD are greater than the saving in reading costs. The introduction of single reading with CAD, in place of double reading, would produce an additional cost of £227 and £253 per 1,000 women screened in high and average volume units respectively. In low volume screening units, the high cost of purchasing the equipment will results in an additional cost of £590 per 1,000 women screened. One-way sensitivity analysis showed that the factors having the greatest effect on the cost-effectiveness of CAD with single reading compared with double reading were the reading time and the reader's professional qualification (radiologist versus advanced practitioner). Conclusions Without improvements in CAD effectiveness (e.g. a decrease in the recall rate) CAD is unlikely to be a cost effective alternative to double reading for mammography screening in UK. This study provides updated estimates of CAD costs in a full-field digital system and assessment cost for women who are re-called after initial screening. However, the model is highly sensitive to various parameters e.g. reading time, reader qualification, and equipment cost. PMID:21241473
Hatipoglu, Nuh; Bilgin, Gokhan
2017-10-01
In many computerized methods for cell detection, segmentation, and classification in digital histopathology that have recently emerged, the task of cell segmentation remains a chief problem for image processing in designing computer-aided diagnosis (CAD) systems. In research and diagnostic studies on cancer, pathologists can use CAD systems as second readers to analyze high-resolution histopathological images. Since cell detection and segmentation are critical for cancer grade assessments, cellular and extracellular structures should primarily be extracted from histopathological images. In response, we sought to identify a useful cell segmentation approach with histopathological images that uses not only prominent deep learning algorithms (i.e., convolutional neural networks, stacked autoencoders, and deep belief networks), but also spatial relationships, information of which is critical for achieving better cell segmentation results. To that end, we collected cellular and extracellular samples from histopathological images by windowing in small patches with various sizes. In experiments, the segmentation accuracies of the methods used improved as the window sizes increased due to the addition of local spatial and contextual information. Once we compared the effects of training sample size and influence of window size, results revealed that the deep learning algorithms, especially convolutional neural networks and partly stacked autoencoders, performed better than conventional methods in cell segmentation.
Optic disk localization by a robust fusion method
NASA Astrophysics Data System (ADS)
Zhang, Jielin; Yin, Fengshou; Wong, Damon W. K.; Liu, Jiang; Baskaran, Mani; Cheng, Ching-Yu; Wong, Tien Yin
2013-02-01
The optic disk localization plays an important role in developing computer-aided diagnosis (CAD) systems for ocular diseases such as glaucoma, diabetic retinopathy and age-related macula degeneration. In this paper, we propose an intelligent fusion of methods for the localization of the optic disk in retinal fundus images. Three different approaches are developed to detect the location of the optic disk separately. The first method is the maximum vessel crossing method, which finds the region with the most number of blood vessel crossing points. The second one is the multichannel thresholding method, targeting the area with the highest intensity. The final method searches the vertical and horizontal region-of-interest separately on the basis of blood vessel structure and neighborhood entropy profile. Finally, these three methods are combined using an intelligent fusion method to improve the overall accuracy. The proposed algorithm was tested on the STARE database and the ORIGAlight database, each consisting of images with various pathologies. The preliminary result on the STARE database can achieve 81.5%, while a higher result of 99% can be obtained for the ORIGAlight database. The proposed method outperforms each individual approach and state-of-the-art method which utilizes an intensity-based approach. The result demonstrates a high potential for this method to be used in retinal CAD systems.
NASA Astrophysics Data System (ADS)
Fetita, C.; Chang-Chien, K. C.; Brillet, P. Y.; Pr"teux, F.; Chang, R. F.
2012-03-01
Our study aims at developing a computer-aided diagnosis (CAD) system for fully automatic detection and classification of pathological lung parenchyma patterns in idiopathic interstitial pneumonias (IIP) and emphysema using multi-detector computed tomography (MDCT). The proposed CAD system is based on three-dimensional (3-D) mathematical morphology, texture and fuzzy logic analysis, and can be divided into four stages: (1) a multi-resolution decomposition scheme based on a 3-D morphological filter was exploited to discriminate the lung region patterns at different analysis scales. (2) An additional spatial lung partitioning based on the lung tissue texture was introduced to reinforce the spatial separation between patterns extracted at the same resolution level in the decomposition pyramid. Then, (3) a hierarchic tree structure was exploited to describe the relationship between patterns at different resolution levels, and for each pattern, six fuzzy membership functions were established for assigning a probability of association with a normal tissue or a pathological target. Finally, (4) a decision step exploiting the fuzzy-logic assignments selects the target class of each lung pattern among the following categories: normal (N), emphysema (EM), fibrosis/honeycombing (FHC), and ground glass (GDG). According to a preliminary evaluation on an extended database, the proposed method can overcome the drawbacks of a previously developed approach and achieve higher sensitivity and specificity.
CAD - CAM Procedures Used for Rapid Prototyping of Prosthetic Hip Joint Bone
NASA Astrophysics Data System (ADS)
Popa, Luminita I.; Popa, Vasile N.
2016-11-01
The article addresses the issue of rapid prototyping CAD/ CAM procedures, based on CT imaging, for custom implants dedicated to hip arthroplasty and the correlation study to be achieved between femoral canal shape, valued by modern imaging methods, and the prosthesis form. A set of CT images is transformed into a digital model using one of several software packages available for conversion. The purpose of research is to obtain prosthesis with compatible characteristics as close to the physiological, with an optimal adjustment of the prosthesis to the bone in which it is implanted, allowing the recovery of the patient physically, mentally and socially.
Lava ultimate resin nano ceramic for CAD/ CAM: customization case study.
Koller, M; Arnetzl, G V; Holly, L; Arnetzl, G
2012-01-01
Lava Ultimate Resin Nano Ceramic (RNC) blocks are innovative new CAD/CAM materials that make it possible to achieve superior esthetic results in easy steps. The blocks are made of nano ceramic particles embedded in a highly cured resin matrix. Therefore, composite materials can be used to characterize and adjust resin nano ceramic restorations after milling. The milled RNC restorations can be individualized intra-orally or extra-orally, either before or after insertion. Unlike conventional ceramic restorations, customization and glaze firing is neither necessary nor possible with RNC restorations. This opens up the opportunity for intraoral individualization and adaptation of the restorations.
Wind Turbine Blade CAD Models Used as Scaffolding Technique to Teach Design Engineers
ERIC Educational Resources Information Center
Irwin, John
2013-01-01
The Siemens PLM CAD software NX is commonly used for designing mechanical systems, and in complex systems such as the emerging area of wind power, the ability to have a model controlled by design parameters is a certain advantage. Formula driven expressions based on the amount of available wind in an area can drive the amount of effective surface…
A Survey of CAD/CAM Technology Applications in the U.S. Shipbuilding Industry
1984-01-01
operation for drafting. Computer Aided Engineering (CAE) analysis is used primarily to determine the validity of design characteristics and produc- tion...include time standard generation, sea trial analysis , and group Systems integration While no systems surveyed Aided Design (CAD) is the technology... analysis . is the largest problem involving software packages. are truly integrated, many are interfaced. Computer most interfaced category with links
Colour parameters and shade correspondence of CAD-CAM ceramic systems.
Della Bona, Alvaro; Pecho, Oscar E; Ghinea, Razvan; Cardona, Juan C; Pérez, María M
2015-06-01
To evaluate colour differences between (1) CAD-CAM ceramic systems considering shades A1, A2 and A3 and the corresponding nominal shade of VC (Vita Classical shade guide) and (2) shades A1-A2, A2-A3 and A1, A2 and A3 within the same ceramic system. Samples of shades A1, A2 and A3 were fabricated (n=5) from CAD-CAM ceramic blocks (IPS e.max(®) CAD LT and HT, IPS Empress(®) CAD LT and HT, Paradigm™ C, and VITABLOCS(®) Mark II) and polished to 1.0±0.01mm in thickness. Spectral reflectance and colour coordinates were measured using a spectroradiometer inside a viewing booth using the CIE D65 illuminant and the d/0° geometry. Spectral reflectance curves were compared using VAF coefficient and were statistically analyzed using Kruskal-Wallis and the Mann-Whitney U test (α=0.05). Colour coordinates were statistically analyzed using one-way ANOVA, Tukey's test with Bonferroni correction (α=0.001). All colour differences (ΔEab(*) and ΔE00) were analyzed through comparisons with the PT - perceptibility and AT - acceptability thresholds for dental ceramics. ΔE between ceramic systems and its corresponding shade ranged from 6.32 to 13.42 (ΔEab(*)) and 4.48 to 9.30 (ΔE00). ΔE between shades A1-A2, A2-A3 and A1, A2 and A3 ranged, respectively, 1.93-4.82, 1.22-5.59 and 3.63-8.84 (ΔEab(*)); 1.54-3.87, 1.03-3.90 and 2.95-6.51 (ΔE00). Considering the corresponding nominal shade from VC, none of the ceramic systems showed colour differences below the AT. In addition, some ceramic systems showed colour differences below AT (shades A1-A2 and A2-A3) and below PT (shades A2-A3). Careful adjustments should be made to the final shade of CAD-CAM ceramic restorations to reach a clinically acceptable shade match. Copyright © 2015 Elsevier Ltd. All rights reserved.
Integrated geometry and grid generation system for complex configurations
NASA Technical Reports Server (NTRS)
Akdag, Vedat; Wulf, Armin
1992-01-01
A grid generation system was developed that enables grid generation for complex configurations. The system called ICEM/CFD is described and its role in computational fluid dynamics (CFD) applications is presented. The capabilities of the system include full computer aided design (CAD), grid generation on the actual CAD geometry definition using robust surface projection algorithms, interfacing easily with known CAD packages through common file formats for geometry transfer, grid quality evaluation of the volume grid, coupling boundary condition set-up for block faces with grid topology generation, multi-block grid generation with or without point continuity and block to block interface requirement, and generating grid files directly compatible with known flow solvers. The interactive and integrated approach to the problem of computational grid generation not only substantially reduces manpower time but also increases the flexibility of later grid modifications and enhancements which is required in an environment where CFD is integrated into a product design cycle.
Improving Perceptual Skills with 3-Dimensional Animations.
ERIC Educational Resources Information Center
Johns, Janet Faye; Brander, Julianne Marie
1998-01-01
Describes three-dimensional computer aided design (CAD) models for every component in a representative mechanical system; the CAD models made it easy to generate 3-D animations that are ideal for teaching perceptual skills in multimedia computer-based technical training. Fifteen illustrations are provided. (AEF)
Study on the integration approaches to CAD/CAPP/FMS in garment CIMS
NASA Astrophysics Data System (ADS)
Wang, Xiankui; Tian, Wensheng; Liu, Chengying; Li, Zhizhong
1995-08-01
Computer integrated manufacturing system (CIMS), as an advanced methodology, has been applied in many industry fields. There is, however, little research on the application of CIMS in the garment industry, especially on the integrated approach to CAD, CAPP, and FMS in garment CIMS. In this paper, the current situations of CAD, CAPP, and FMS in the garment industry are discussed, and information requirements between them as well as the integrated approaches are also investigated. The representation of the garments' product data by the group technology coding is proposed. Based on the group technology, a shared data base as an integration element can be constructed, which leads to the integration of CAD/CAPP/FMS in garment CIMS.
Vitamin D treatment in calcium-deficiency rickets: a randomised controlled trial.
Thacher, Tom D; Fischer, Philip R; Pettifor, John M
2014-09-01
To determine whether children with calcium-deficiency rickets have a better response to treatment with vitamin D and calcium than with calcium alone. Randomised controlled trial. Jos University Teaching Hospital, Jos, Nigeria. Nigerian children with active rickets treated with calcium carbonate as limestone (approximately 938 mg elemental calcium twice daily) were, in addition, randomised to receive either oral vitamin D2 50,000 IU (Ca+D, n=44) or placebo (Ca, n=28) monthly for 24 weeks. Achievement of a 10-point radiographic severity score ≤1.5 and serum alkaline phosphatase ≤350 U/L. The median (range) age of enrolled children was 46 (15-102) months, and baseline characteristics were similar in the two groups. Mean (±SD) 25-hydroxyvitamin D (25(OH)D) was 30.2±13.2 nmol/L at baseline, and 29 (43%) had values <30 nmol/L. Baseline alkaline phosphatase and radiographic scores were unrelated to vitamin D status. Of the 68 children (94% of original cohort) who completed 24 weeks of treatment, 29 (67%) in the Ca+D group and 11 (44%) in the Ca group achieved the primary outcome (p=0.06). Baseline 25(OH)D did not alter treatment group effects (p=0.99 for interaction). At the end of 24 weeks, 25(OH)D values were 55.4±17.0 nmol/L and 37.9±20.0 nmol/L in the Ca+D and Ca groups, respectively, (p<0.001). In the Ca+D and Ca groups, the final 25(OH)D concentration was greater in those who achieved the primary outcome (56.4±17.2 nmol/L) than in those who did not (37.7±18.5 nmol/L, p<0.001). In children with calcium-deficiency rickets, there is a trend for vitamin D to improve the response to treatment with calcium carbonate as limestone, independent of baseline 25(OH)D concentrations. ClinicalTrials.gov NCT00949832. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Zhang, Zutai; Tamaki, Yukimichi; Hotta, Yasuhiro; Miyazaki, Takashi
2006-07-01
For titanium casting, most commercial investments for titanium recommend casting at a low mold temperature to reduce oxidation. However, the thermal expansion values of the molds at low casting temperatures may be insufficient. The purpose of the current study was to investigate the possibility of obtaining accurate titanium crown casts using wax pattern fabricated by a CAD/CAM system with a non-expanded mold. Three types of experimental magnesia-based investments (A, B and C) were made and their properties were evaluated for dental use. Two kinds of wax patterns for full-coverage coping crowns (S-0: cement space of 0 microm; S-20: cement space of 20 microm) were fabricated using a commercial CAD/CAM system. A traditional method (TM) using inlay wax was performed for comparison. The investment for titanium casting was decided from the fundamental data of experimental investments. Titanium crowns were replaced on the stone die and the thickness of the cement layer was evaluated. There were no significant differences for the setting time and setting expansion among the experimental investments, but the aluminous cement content played a role in hardening and contracting the mold. The fit of the titanium crowns differed significantly between the TM and the CAD/CAM system. The ranges of thickness obtained from the TM, S-0 and S-20 were 20.78-357.88 microm, 25.12-107.46 microm and 17.84-58.92 microm, respectively. High quality titanium crown casting was obtained using a combination of wax patterns fabricated by a CAD/CAM system and a non-expanded MgO-based investment.
Computer-aided-diagnosis (CAD) for colposcopy
NASA Astrophysics Data System (ADS)
Lange, Holger; Ferris, Daron G.
2005-04-01
Uterine cervical cancer is the second most common cancer among women worldwide. Colposcopy is a diagnostic method, whereby a physician (colposcopist) visually inspects the lower genital tract (cervix, vulva and vagina), with special emphasis on the subjective appearance of metaplastic epithelium comprising the transformation zone on the cervix. Cervical cancer precursor lesions and invasive cancer exhibit certain distinctly abnormal morphologic features. Lesion characteristics such as margin; color or opacity; blood vessel caliber, intercapillary spacing and distribution; and contour are considered by colposcopists to derive a clinical diagnosis. Clinicians and academia have suggested and shown proof of concept that automated image analysis of cervical imagery can be used for cervical cancer screening and diagnosis, having the potential to have a direct impact on improving women"s health care and reducing associated costs. STI Medical Systems is developing a Computer-Aided-Diagnosis (CAD) system for colposcopy -- ColpoCAD. At the heart of ColpoCAD is a complex multi-sensor, multi-data and multi-feature image analysis system. A functional description is presented of the envisioned ColpoCAD system, broken down into: Modality Data Management System, Image Enhancement, Feature Extraction, Reference Database, and Diagnosis and directed Biopsies. The system design and development process of the image analysis system is outlined. The system design provides a modular and open architecture built on feature based processing. The core feature set includes the visual features used by colposcopists. This feature set can be extended to include new features introduced by new instrument technologies, like fluorescence and impedance, and any other plausible feature that can be extracted from the cervical data. Preliminary results of our research on detecting the three most important features: blood vessel structures, acetowhite regions and lesion margins are shown. As this is a new and very complex field in medical image processing, the hope is that this paper can provide a framework and basis to encourage and facilitate collaboration and discussion between industry, academia, and medical practitioners.
Comparative characterization of a novel cad-cam polymer-infiltrated-ceramic-network
Pascual, Agustín; Camps, Isabel; Grau-Benitez, María
2015-01-01
Background The field of dental ceramics for CAD-CAM is enriched with a new innovative material composition having a porous three-dimensional structure of feldspathic ceramic infiltrated with acrylic resins.The aim of this study is to determine the mechanical properties of Polymer-Infiltrated-Ceramic-Network (PICN) and compare its performance with other ceramics and a nano-ceramic resin available for CAD-CAM systems. Material and Methods In this study a total of five different materials for CAD-CAM were investigated. A polymer-infiltrated ceramic (Vita Enamic), a nano-ceramic resin (Lava Ultimate), a feldspathic ceramic (Mark II), a lithium disilicate ceramic (IPS-e max CAD) and finally a Leucite based ceramic (Empress - CAD). From CAD-CAM blocks, 120 bars (30 for each material cited above) were cut to measure the flexural strength with a three-point-bending test. Strain at failure, fracture stress and Weibull modulus was calculated. Vickers hardness of each material was also measured. Results IPS-EMAX presents mechanical properties significantly better from the other materials studied. Its strain at failure, flexural strength and hardness exhibited significantly higher values in comparison with the others. VITA ENAMIC and LAVA ULTIMATE stand out as the next most resistant materials. Conclusions The flexural strength, elastic modulus similar to a tooth as well as having less hardness than ceramics make PICN materials an option to consider as a restorative material. Key words:Ceramic infiltrated with resin, CAD-CAM, Weibull modulus, flexural strength, micro hardness. PMID:26535096
Liebermann, Anja; Rafael, Caroline Freitas; Edelhoff, Daniel; Ramberger, Marc; Schweiger, Josef; Maziero Volpato, Claudia Angela; Saeidi Pour, Reza
2017-04-01
Patients with CHARGE syndrome (where CHARGE stands for coloboma of the iris or retina, heart defects or cardiac malformations, atresia/stenosis of the choanae, retardation of growth and development, genital anomalies, and ear abnormalities) present several orofacial anomalies. Their treatment depends on the specific type of manifestation. To perform the complex oral rehabilitation and achieve a conservative, esthetic, and functional exploration of the definitive treatment goal, computer-aided design and computer-aided manufacturing (CAD-CAM) polymers can be used as long-term interim restorations. This article reports the treatment of a young patient with CHARGE syndrome combined with oral alterations. CAD-CAM polymers offer an intermediate treatment with satisfying esthetics and function at low biological cost until bone growth is completed. This period facilitates additional planning for the definitive restoration. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Baessler, Andrea; Fischer, Marcus; Mayer, Bjoern; Koehler, Martina; Wiedmann, Silke; Stark, Klaus; Doering, Angela; Erdmann, Jeanette; Riegger, Guenter; Schunkert, Heribert; Kwitek, Anne E; Hengstenberg, Christian
2007-04-15
Data from both experimental models and humans provide evidence that ghrelin and its receptor, the growth hormone secretagogue receptor (ghrelin receptor, GHSR), possess a variety of cardiovascular effects. Thus, we hypothesized that genetic variants within the ghrelin system (ligand ghrelin and its receptor GHSR) are associated with susceptibility to myocardial infarction (MI) and coronary artery disease (CAD). Seven single nucleotide polymorphisms (SNPs) covering the GHSR region as well as eight SNPs across the ghrelin gene (GHRL) region were genotyped in index MI patients (864 Caucasians, 'index MI cases') from the German MI family study and in matched controls without evidence of CAD (864 Caucasians, 'controls', MONICA Augsburg). In addition, siblings of these MI patients with documented severe CAD (826 'affected sibs') were matched likewise with controls (n = 826 Caucasian 'controls') and used for verification. The effect of interactions between genetic variants of both genes of the ghrelin system was explored by conditional classification tree models. We found association of several GHSR SNPs with MI [best SNP odds ratio (OR) 1.7 (1.2-2.5); P = 0.002] using a recessive model. Moreover, we identified a common GHSR haplotype which significantly increases the risk for MI [multivariate adjusted OR for homozygous carriers 1.6 (1.1-2.5) and CAD OR 1.6 (1.1-2.5)]. In contrast, no relationship between genetic variants and the disease could be revealed for GHRL. However, the increase in MI/CAD frequency related to the susceptible GHSR haplotype was abolished when it coincided with a common GHRL haplotype. Multivariate adjustments as well as permutation-based methods conveyed the same results. These data are the first to demonstrate an association of SNPs and haplotypes within important genes of the ghrelin system and the susceptibility to MI, whereas association with MI/CAD could be identified for genetic variants across GHSR, no relationship could be revealed for GHRL itself. However, we found an effect of GHRL dependent upon the presence of a common, MI and CAD susceptible haplotype of GHSR. Thus, our data suggest that specific haplotypes of the ghrelin ligand and its receptor act epistatically to affect susceptibility or tolerance to MI and/or CAD.
Automated Sneak Circuit Analysis Technique
1990-06-01
the OrCAD/SDT module Port facility. 2. The terminals of all in- circuit voltage sources (e , batteries) must be labeled using the OrCAD/SDT module port...ELECTE 1 MAY 2 01994 _- AUTOMATED SNEAK CIRCUIT ANALYSIS TECHNIQUEIt~ w I wtA who RADC 94-14062 Systems Reliability & Engineering Division Rome...Air Develpment Center Best Avai~lable copy AUTOMATED SNEAK CIRCUIT ANALYSIS TECHNIQUE RADC June 1990 Systems Reliability & Engineering Division Rome Air
[An experimental research on the fabrication of the fused porcelain to CAD/CAM molar crown].
Dai, Ning; Zhou, Yongyao; Liao, Wenhe; Yu, Qing; An, Tao; Jiao, Yiqun
2007-02-01
This paper introduced the fabrication process of the fused porcelain to molar crown with CAD/CAM technology. Firstly, preparation teeth data was retrieved by the 3D-optical measuring system. Then, we have reconstructed the inner surface designed the outer surface shape with the computer aided design software. Finally, the mini high-speed NC milling machine was used to produce the fused porcelain to CAD/CAM molar crown. The result has proved that the fabrication process is reliable and efficient. The dental restoration quality is steady and precise.
Sanchez-Alcoholado, Lidia; Castellano-Castillo, Daniel; Jordán-Martínez, Laura; Moreno-Indias, Isabel; Cardila-Cruz, Pilar; Elena, Daniel; Muñoz-Garcia, Antonio J.; Jimenez-Navarro, Manuel
2017-01-01
Gut microbiota composition has been reported as a factor linking host metabolism with the development of cardiovascular diseases (CVD) and intestinal immunity. Such gut microbiota has been shown to aggravate CVD by contributing to the production of trimethylamine N-oxide (TMAO), which is a pro-atherogenic compound. Treg cells expressing the transcription factor Forkhead box protein P3 (FoxP3) play an essential role in the regulation of immune responses to commensal microbiota and have an atheroprotective role. However, the aim of this study was to analyze the role of gut microbiota on cardio-metabolic parameters and immunity in coronary artery disease (CAD) patients with and without type-2 diabetes mellitus (DM2). The study included 16 coronary CAD-DM2 patients, and 16 age, sex, and BMI matched CAD patients without DM2 (CAD-NDM2). Fecal bacterial DNA was extracted and analyzed by sequencing in a GS Junior 454 platform followed by a bioinformatic analysis (QIIME and PICRUSt). The present study indicated that the diversity and composition of gut microbiota were different between the CAD-DM2 and CAD-NDM2 patients. The abundance of phylum Bacteroidetes was lower, whereas the phyla Firmicutes and Proteobacteria were higher in CAD-DM2 patients than those in the CAD-NDM2 group. CAD-DM2 patients had significantly less beneficial or commensal bacteria (such as Faecalibacterium prausnitzii and Bacteroides fragilis) and more opportunistic pathogens (such as Enterobacteriaceae, Streptococcus, and Desulfovibrio). Additionally, CAD-DM2 patients had significantly higher levels of plasma zonulin, TMAO, and IL-1B and significantly lower levels of IL-10 and FOXP3 mRNA expression than CAD-NDM2. Moreover, in the CAD-MD2 group, the increase in Enterobacteriaceae and the decrease in Faecalibacterium prausnitzii were significantly associated with the increase in serum TMAO levels, while the decrease in the abundance of Bacteroides fragilis was associated with the reduction in the FOXP3 mRNA expression, implicated in the development and function of Treg cells. These results suggest that the presence of DM2 is related to an impaired regulation of the immune system in CAD patients, mediated in part by the gut microbiota composition and functionality and the production and effects of their gut microbiota derived molecules. PMID:29051757
Computer-aided diagnosis (CAD) for colonoscopy
NASA Astrophysics Data System (ADS)
Gu, Jia; Poirson, Allen
2007-03-01
Colorectal cancer is the second leading cause of cancer deaths, and ranks third for new cancer cases and cancer mortality for both men and women. However, its death rate can be dramatically reduced by appropriate treatment when early detection is available. The purpose of colonoscopy is to identify and assess the severity of lesions, which may be flat or protruding. Due to the subjective nature of the examination, colonoscopic proficiency is highly variable and dependent upon the colonoscopist's knowledge and experience. An automated image processing system providing an objective, rapid, and inexpensive analysis of video from a standard colonoscope could provide a valuable tool for screening and diagnosis. In this paper, we present the design, functionality and preliminary results of its Computer-Aided-Diagnosis (CAD) system for colonoscopy - ColonoCAD TM. ColonoCAD is a complex multi-sensor, multi-data and multi-algorithm image processing system, incorporating data management and visualization, video quality assessment and enhancement, calibration, multiple view based reconstruction, feature extraction and classification. As this is a new field in medical image processing, our hope is that this paper will provide the framework to encourage and facilitate collaboration and discussion between industry, academia, and medical practitioners.
Weinsaft, Jonathan W; Manoushagian, Shant J; Patel, Taral; Shakoor, Aqsa; Kim, Robert J; Mirchandani, Sunil; Lin, Fay; Wong, Franklin J; Szulc, Massimiliano; Okin, Peter M; Kligfield, Paul D; Min, James K
2009-01-01
To assess the utility of stress electrocardiography (ECG) for identifying the presence and severity of obstructive coronary artery disease (CAD) defined by coronary computed tomographic angiography (CCTA) among patients with normal nuclear myocardial perfusion imaging (MPI). The study population comprised 119 consecutive patients with normal MPI who also underwent CCTA (interval 3.5+/-3.8 months). Stress ECG was performed at the time of MPI. CCTA and MPI were interpreted using established scoring systems, and CCTA was used to define the presence and extent of CAD, which was quantified by a coronary artery jeopardy score. Within this population, 28 patients (24%) had obstructive CAD identified by CCTA. The most common CAD pattern was single-vessel CAD (61%), although proximal vessel involvement was present in 46% of patients. Patients with CAD were nearly three times more likely to have positive standard test responses (1 mm ST-segment deviation) than patients with patent coronary arteries (36 vs. 13%, P=0.007). In multivariate analysis, a positive ST-segment test response was an independent marker for CAD (odds ratio: 2.02, confidence interval: 1.09-3.78, P=0.03) even after adjustment for a composite of clinical cardiac risk factors (odds ratio: 1.85, confidence interval: 1.05-3.23, P=0.03). Despite uniformly normal MPI, mean coronary jeopardy score was three-fold higher among patients with positive compared to those with negative ST-segment response to exercise or dobutamine stress (1.9+/-2.7 vs. 0.5+/-1.4, P=0.03). Stress-induced ST-segment deviation is an independent marker for obstructive CAD among patients with normal MPI. A positive stress ECG identifies patients with a greater anatomic extent of CAD as quantified by coronary jeopardy score.
Structured reporting platform improves CAD-RADS assessment.
Szilveszter, Bálint; Kolossváry, Márton; Karády, Júlia; Jermendy, Ádám L; Károlyi, Mihály; Panajotu, Alexisz; Bagyura, Zsolt; Vecsey-Nagy, Milán; Cury, Ricardo C; Leipsic, Jonathon A; Merkely, Béla; Maurovich-Horvat, Pál
2017-11-01
Structured reporting in cardiac imaging is strongly encouraged to improve quality through consistency. The Coronary Artery Disease - Reporting and Data System (CAD-RADS) was recently introduced to facilitate interdisciplinary communication of coronary CT angiography (CTA) results. We aimed to assess the agreement between manual and automated CAD-RADS classification using a structured reporting platform. Five readers prospectively interpreted 500 coronary CT angiographies using a structured reporting platform that automatically calculates the CAD-RADS score based on stenosis and plaque parameters manually entered by the reader. In addition, all readers manually assessed CAD-RADS blinded to the automatically derived results, which was used as the reference standard. We evaluated factors influencing reader performance including CAD-RADS training, clinical load, time of the day and level of expertise. Total agreement between manual and automated classification was 80.2%. Agreement in stenosis categories was 86.7%, whereas the agreement in modifiers was 95.8% for "N", 96.8% for "S", 95.6% for "V" and 99.4% for "G". Agreement for V improved after CAD-RADS training (p = 0.047). Time of the day and clinical load did not influence reader performance (p > 0.05 both). Less experienced readers had a higher total agreement as compared to more experienced readers (87.0% vs 78.0%, respectively; p = 0.011). Even though automated CAD-RADS classification uses data filled in by the readers, it outperforms manual classification by preventing human errors. Structured reporting platforms with automated calculation of the CAD-RADS score might improve data quality and support standardization of clinical decision making. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
On the Design of a CADS for Shoulder Pain Pathology
NASA Astrophysics Data System (ADS)
de Ipiña, K. López; Hernández, M. C.; Martínez, E.; Vaquero, C.
A musculoskeletal disorder is a condition of the musculoskeletal system, which consists in part of it being injured continuously over time. Shoulder disorders are one of the most common musculoskeletal cases attended in primary health care services. Shoulder disorders cause pain and limit the ability to perform many routine activities, affecting about 15-25 % of the general population. Several clinical tests have been described to aid diagnosis of shoulder disorders. However, the current literature acknowledges a lack of concordance in clinical assessment, even among musculoskeletal specialists. We are working on the design of a Computer-Aided Decision Support (CADS) system for Shoulder Pain Pathology. The paper presents the results of our efforts to build a CADS system testing several classical classification paradigms, feature reduction methods (PCA) and K-means unsupervised clustering. The small database size imposes the use of robust covariance matrix estimation methods to improve the system performance. Finally, the system was evaluated by a medical specialist.
Tanaka, Toyohiko; Nitta, Norihisa; Ohta, Shinichi; Kobayashi, Tsuyoshi; Kano, Akiko; Tsuchiya, Keiko; Murakami, Yoko; Kitahara, Sawako; Wakamiya, Makoto; Furukawa, Akira; Takahashi, Masashi; Murata, Kiyoshi
2009-12-01
A computer-aided detection (CAD) system was evaluated for its ability to detect microcalcifications and masses on images obtained with a digital phase-contrast mammography (PCM) system, a system characterised by the sharp images provided by phase contrast and by the high resolution of 25-μm-pixel mammograms. Fifty abnormal and 50 normal mammograms were collected from about 3,500 mammograms and printed on film for reading on a light box. Seven qualified radiologists participated in an observer study based on receiver operating characteristic (ROC) analysis. The average of the areas under ROC curve (AUC) values for the ROC analysis with and without CAD were 0.927 and 0.897 respectively (P = 0.015). The AUC values improved from 0.840 to 0.888 for microcalcifications (P = 0.034) and from 0.947 to 0.962 for masses (P = 0.025) respectively. The application of CAD to the PCM system is a promising approach for the detection of breast cancer in its early stages.
A CAD approach to magnetic bearing design
NASA Technical Reports Server (NTRS)
Jeyaseelan, M.; Anand, D. K.; Kirk, J. A.
1988-01-01
A design methodology has been developed at the Magnetic Bearing Research Laboratory for designing magnetic bearings using a CAD approach. This is used in the algorithm of an interactive design software package. The package is a design tool developed to enable the designer to simulate the entire process of design and analysis of the system. Its capabilities include interactive input/modification of geometry, finding any possible saturation at critical sections of the system, and the design and analysis of a control system that stabilizes and maintains magnetic suspension.
Electronic Computer Aided Design. Its Application in FE.
ERIC Educational Resources Information Center
Further Education Unit, London (England).
A study was conducted at the Electronics Industrial Unit at the Dorset Institute of Higher Education to investigate the feasibility of incorporating computer-aided design (CAD) in electrical and electronic courses. The aim was to investigate the application of CAD to electrical and electronic systems; the extent to which industrial developments…
NASA Technical Reports Server (NTRS)
Bruce, E. A.
1980-01-01
The software developed by the IPAD project, a new and very powerful tool for the implementation of integrated Computer Aided Design (CAD) systems in the aerospace engineering community, is discussed. The IPAD software is a tool and, as such, can be well applied or misapplied in any particular environment. The many benefits of an integrated CAD system are well documented, but there are few such systems in existence, especially in the mechanical engineering disciplines, and therefore little available experience to guide the implementor.
Derelioglu, Sera
2016-01-01
Objective. The aim of this study was to compare to fracture resistance test of inlay restorations prepared using direct inlay technique (Gradia® Direct Composite) and Indirect Restoration System® (Gradia Indirect Composite) and CAD/CAD system (Vita Enamic® Block). Study Design. 48 noncarious extracted maxillary second primary molars were randomly divided into 4 groups with 12 in each group. All the teeth were prepared based on inlay class II preparations except for the control group. Other groups were restored with Gradia Direct Composite, Gradia Indirect Composite, and Vita Enamic Block, respectively. All restorations were cemented self-adhesive dual cure resin (3M Espe, RelyX™ Unicem Aplicap). A fracture test was performed using a compressive load. Results were analyzed using one-way analysis of variance and Duncan's post hoc multiple comparison tests (α = 0.05). Results. Vita Enamic Block and Gradia Indirect Composite showed significantly higher fracture resistance than Gradia Direct Composite (p < 0.05). There was no significant difference fracture resistance between Vita Enamic Block and Gradia Indirect Composite (p > 0.05). All restorations tested led to a significant reduction in fracture resistance (p < 0.05). Conclusion. In inlay restorations, Indirect Restoration Systems and CAD/CAM systems were applied successfully together with the self-adhesive dual cure resin cements in primary molars. PMID:27830145
Digital impression and jaw relation record for the fabrication of CAD/CAM custom tray.
Kanazawa, Manabu; Iwaki, Maiko; Arakida, Toshio; Minakuchi, Shunsuke
2018-03-16
This article describes the protocol of a digital impression technique to make an impression and recording of the jaw relationship of edentulous patients for the fabrication of CAD/CAM custom tray using computer-aided design and manufacturing (CAD/CAM) technology. Scan the maxillary and mandibular edentulous jaws using an intraoral scanner. Scan the silicone jig with the maxillary and mandibular jaws while keeping the jig between the jaws. Import the standard tessellation language data of the maxillary and mandibular jaws and jig to make a jaw relation record and fabricate custom trays (CAD/CAM trays) using a rapid prototyping system. Make a definitive impression of the maxillary and mandibular jaws using the CAD/CAM trays. Digitalization of the complete denture fabrication process can simplify the complicated treatment and laboratory process of conventional methods In addition, the proposed method enables quality control regardless of the operator's experience and technique. Copyright © 2018. Published by Elsevier Ltd.
Rewiring a secondary metabolite pathway towards itaconic acid production in Aspergillus niger.
Hossain, Abeer H; Li, An; Brickwedde, Anja; Wilms, Lars; Caspers, Martien; Overkamp, Karin; Punt, Peter J
2016-07-28
The industrially relevant filamentous fungus Aspergillus niger is widely used in industry for its secretion capabilities of enzymes and organic acids. Biotechnologically produced organic acids promise to be an attractive alternative for the chemical industry to replace petrochemicals. Itaconic acid (IA) has been identified as one of the top twelve building block chemicals which have high potential to be produced by biotechnological means. The IA biosynthesis cluster (cadA, mttA and mfsA) has been elucidated in its natural producer Aspergillus terreus and transferred to A. niger to enable IA production. Here we report the rewiring of a secondary metabolite pathway towards further improved IA production through the overexpression of a putative cytosolic citrate synthase citB in a A. niger strain carrying the IA biosynthesis cluster. We have previously shown that expression of cadA from A. terreus results in itaconic acid production in A. niger AB1.13, albeit at low levels. This low-level production is boosted fivefold by the overexpression of mttA and mfsA in itaconic acid producing AB1.13 CAD background strains. Controlled batch cultivations with AB1.13 CAD + MFS + MTT strains showed increased production of itaconic acid compared with AB1.13 CAD strain. Moreover, preliminary RNA-Seq analysis of an itaconic acid producing AB1.13 CAD strain has led to the identification of the putative cytosolic citrate synthase citB which was induced in an IA producing strain. We have overexpressed citB in a AB1.13 CAD + MFS + MTT strain and by doing so hypothesize to have targeted itaconic acid production to the cytosolic compartment. By overexpressing citB in AB1.13 CAD + MFS + MTT strains in controlled batch cultivations we have achieved highly increased titers of up to 26.2 g/L IA with a productivity of 0.35 g/L/h while no CA was produced. Expression of the IA biosynthesis cluster in Aspergillus niger AB1.13 strain enables IA production. Moreover, in the AB1.13 CAD strain IA production resulted in overexpression of a putative cytosolic citrate synthase citB. Upon overexpression of citB we have achieved titers of up to 26.2 g/L IA with a productivity of 0.35 g/L/h in controlled batch cultivations. By overexpressing citB we have also diminished side product formation and optimized the production pathway towards IA.
Symmetry-based detection and diagnosis of DCIS in breast MRI
NASA Astrophysics Data System (ADS)
Srikantha, Abhilash; Harz, Markus T.; Newstead, Gillian; Wang, Lei; Platel, Bram; Hegenscheid, Katrin; Mann, Ritse M.; Hahn, Horst K.; Peitgen, Heinz-Otto
2013-02-01
The delineation and diagnosis of non-mass-like lesions, most notably DCIS (ductal carcinoma in situ), is among the most challenging tasks in breast MRI reading. Even for human observers, DCIS is not always easy to diferentiate from patterns of active parenchymal enhancement or from benign alterations of breast tissue. In this light, it is no surprise that CADe/CADx approaches often completely fail to classify DCIS. Of the several approaches that have tried to devise such computer aid, none achieve performances similar to mass detection and classification in terms of sensitivity and specificity. In our contribution, we show a novel approach to combine a newly proposed metric of anatomical breast symmetry calculated on subtraction images of dynamic contrast-enhanced (DCE) breast MRI, descriptive kinetic parameters, and lesion candidate morphology to achieve performances comparable to computer-aided methods used for masses. We have based the development of the method on DCE MRI data of 18 DCIS cases with hand-annotated lesions, complemented by DCE-MRI data of nine normal cases. We propose a novel metric to quantify the symmetry of contralateral breasts and derive a strong indicator for potentially malignant changes from this metric. Also, we propose a novel metric for the orientation of a finding towards a fix point (the nipple). Our combined scheme then achieves a sensitivity of 89% with a specificity of 78%, matching CAD results for breast MRI on masses. The processing pipeline is intended to run on a CAD server, hence we designed all processing to be automated and free of per-case parameters. We expect that the detection results of our proposed non-mass aimed algorithm will complement other CAD algorithms, or ideally be joined with them in a voting scheme.
Arunyanak, Sirikarn P; Harris, Bryan T; Grant, Gerald T; Morton, Dean; Lin, Wei-Shao
2016-07-01
This report describes a digital approach for computer-guided surgery and immediate provisionalization in a partially edentulous patient. With diagnostic data obtained from cone-beam computed tomography and intraoral digital diagnostic scans, a digital pathway of virtual diagnostic waxing, a virtual prosthetically driven surgical plan, a computer-aided design and computer-aided manufacturing (CAD/CAM) surgical template, and implant-supported screw-retained interim restorations were realized with various open-architecture CAD/CAM systems. The optional CAD/CAM diagnostic casts with planned implant placement were also additively manufactured to facilitate preoperative inspection of the surgical template and customization of the CAD/CAM-fabricated interim restorations. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
The 28-entity IGES test file results using ComputerVision CADDS 4X
NASA Technical Reports Server (NTRS)
Kuan, Anchyi; Shah, Saurin; Smith, Kevin
1987-01-01
The investigation was based on the following steps: (1) Read the 28 Entity IGES (Initial Graphics Exchange Specification) Test File into the CAD data base with the IGES post-processor; (2) Make the modifications to the displayed geometries, which should produce the normalized front view and the drawing entity defined display; (3) Produce the drawing entity defined display of the file as it appears in the CAD system after modification to the geometry; (4) Translate the file back to IGES format using IGES pre-processor; (5) Read the IGES file produced by the pre-processor back into the CAD data base; (6) Produce another drawing entity defined display of the CAD display; and (7) Compare the plots resulting from steps 3 and 6 - they should be identical to each other.
Pintó, Xavier; Meco, José F; Corbella, Emili; Figueras, Rosaura; Pallarés, Carlos; Esplugas, Enric; Castiñeiras, María J; Marrugat, Jaume; Pujol, Ramon
2003-05-31
Lipid therapeutic goals are not achieved in a high percentage of patients with coronary artery disease (CAD). We describe in this paper the methodology and results of the Hospital Universitario de Bellvitge Atherosclerosis Secondary Preventive Program (PPSHB), which is aimed at preventing ischemic recurrences by controlling atherogenic factors. From January 1992 to December 1996, 882 patients with acute CAD entered the PPSHB and were seen on at least 2 occasions at the Unidad de Lípidos y Arteriosclerosis during a mean period of 10.4 (3.8) months. In 753 patients data on clinical follow-up were available. Follow-up data were collected by telephone interview and review of medical records. During the follow-up period at the Unidad de Lípidos y Arteriosclerosis, 71.9% of patients achieved the therapeutic goals or their LDLc improved >= 15%. These results were seen in 83.6%, 78.7% and 83.6% of patients with regard to HDLc, triglycerides and HDLc/LDLc ratio, respectively, while the percentage of patients receiving lipid-lowering drugs increased from 28% to 69%. During a follow-up of 33.7 (15.9) months, death (all causes; mean survival time: 20 [13.4] months) occurred in 41 patients (5.4%). On the other hand, hospitalization for cardiovascular disease was required in 113 patients (15%) during a mean follow-up until the first admission of 18.4 (14.2) months. The main independent predictor of unfavourable clinical course was not to reach the HDLc/LDLc ratio goal (HDLc/LDLc >= 0.27 or an increase >= 15%; OR = 2.1; 95% CI, 1.1-4.03). A systematic secondary preventive strategy may help achieve an adequate control of dyslipidemia in most CAD patients. In these patients, achieving the HDLc/LDLc therapeutic goal is associated with a less than half risk of hospitalization for cardiovascular disease or death from any cause.
Wong, M S; Cheng, J C Y; Wong, M W; So, S F
2005-04-01
A study was conducted to compare the CAD/CAM method with the conventional manual method in fabrication of spinal orthoses for patients with adolescent idiopathic scoliosis. Ten subjects were recruited for this study. Efficiency analyses of the two methods were performed from cast filling/ digitization process to completion of cast/image rectification. The dimensional changes of the casts/ models rectified by the two cast rectification methods were also investigated. The results demonstrated that the CAD/CAM method was faster than the conventional manual method in the studied processes. The mean rectification time of the CAD/CAM method was shorter than that of the conventional manual method by 108.3 min (63.5%). This indicated that the CAD/CAM method took about 1/3 of the time of the conventional manual to finish cast rectification. In the comparison of cast/image dimensional differences between the conventional manual method and the CAD/CAM method, five major dimensions in each of the five rectified regions namely the axilla, thoracic, lumbar, abdominal and pelvic regions were involved. There were no significant dimensional differences (p < 0.05) in 19 out of the 25 studied dimensions. This study demonstrated that the CAD/CAM system could save the time in the rectification process and offer a relatively high resemblance in cast rectification as compared with the conventional manual method.
Xu, X W; Doi, K; Kobayashi, T; MacMahon, H; Giger, M L
1997-09-01
Lung cancer is the leading cause of cancer deaths in men and women in the United States, with a 5-year survival rate of only about 13%. However, this survival rate can be improved to 47% if the disease is diagnosed and treated at an early stage. In this study, we developed an improved computer-aided diagnosis (CAD) scheme for the automated detection of lung nodules in digital chest images to assist radiologists, who could miss up to 30% of the actually positive cases in their daily practice. Two hundred PA chest radiographs, 100 normals and 100 abnormals, were used as the database for our study. The presence of nodules in the 100 abnormal cases was confirmed by two experienced radiologists on the basis of CT scans or radiographic follow-up. In our CAD scheme, nodule candidates were selected initially by multiple gray-level thresholding of the difference image (which corresponds to the subtraction of a signal-enhanced image and a signal-suppressed image) and then classified into six groups. A large number of false positives were eliminated by adaptive rule-based tests and an artificial neural network (ANN). The CAD scheme achieved, on average, a sensitivity of 70% with 1.7 false positives per chest image, a performance which was substantially better as compared with other studies. The CPU time for the processing of one chest image was about 20 seconds on an IBM RISC/6000 Powerstation 590. We believe that the CAD scheme with the current performance is ready for initial clinical evaluation.
2015-01-01
PURPOSE To describe and characterize the surface topography and cleanliness of CAD/CAM manufactured zirconia abutments after steaming and ultrasonic cleaning. MATERIALS AND METHODS A total of 12 ceramic CAD/CAM implant abutments of various manufacturers were produced and randomly divided into two groups of six samples each (control and test group). Four two-piece hybrid abutments and two one-piece abutments made of zirconium-dioxide were assessed per each group. In the control group, cleaning by steam was performed. The test group underwent an ultrasonic cleaning procedure with acetone, ethyl alcohol and antibacterial solution. Groups were subjected to scanning electron microscope (SEM) analysis and Energy-dispersive X-ray spectroscopy (EDX) to verify and characterize contaminant chemical characterization non-quantitatively. RESULTS All zirconia CAD/CAM abutments in the present study displayed production-induced wear particles, debris as well as organic and inorganic contaminants. The abutments of the test group showed reduction of surface contamination after undergoing an ultrasonic cleaning procedure. However, an absolute removal of pollutants could not be achieved. CONCLUSION The presence of debris on the transmucosal surface of CAD/CAM zirconia abutments of various manufacturers was confirmed. Within the limits of the study design, the results suggest that a defined ultrasonic cleaning process can be advantageously employed to reduce such debris, thus, supposedly enhancing soft tissue healing. Although the adverse long-term influence of abutment contamination on the biological stability of peri-implant tissues has been evidenced, a standardized and validated polishing and cleaning protocol still has to be implemented. PMID:25932314
NASA Astrophysics Data System (ADS)
Tsehay, Yohannes K.; Lay, Nathan S.; Roth, Holger R.; Wang, Xiaosong; Kwak, Jin Tae; Turkbey, Baris I.; Pinto, Peter A.; Wood, Brad J.; Summers, Ronald M.
2017-03-01
Prostate cancer (PCa) is the second most common cause of cancer related deaths in men. Multiparametric MRI (mpMRI) is the most accurate imaging method for PCa detection; however, it requires the expertise of experienced radiologists leading to inconsistency across readers of varying experience. To increase inter-reader agreement and sensitivity, we developed a computer-aided detection (CAD) system that can automatically detect lesions on mpMRI that readers can use as a reference. We investigated a convolutional neural network based deep-learing (DCNN) architecture to find an improved solution for PCa detection on mpMRI. We adopted a network architecture from a state-of-the-art edge detector that takes an image as an input and produces an image probability map. Two-fold cross validation along with a receiver operating characteristic (ROC) analysis and free-response ROC (FROC) were used to determine our deep-learning based prostate-CAD's (CADDL) performance. The efficacy was compared to an existing prostate CAD system that is based on hand-crafted features, which was evaluated on the same test-set. CADDL had an 86% detection rate at 20% false-positive rate while the top-down learning CAD had 80% detection rate at the same false-positive rate, which translated to 94% and 85% detection rate at 10 false-positives per patient on the FROC. A CNN based CAD is able to detect cancerous lesions on mpMRI of the prostate with results comparable to an existing prostate-CAD showing potential for further development.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Biondo, Elliott D; Ibrahim, Ahmad M; Mosher, Scott W
2015-01-01
Detailed radiation transport calculations are necessary for many aspects of the design of fusion energy systems (FES) such as ensuring occupational safety, assessing the activation of system components for waste disposal, and maintaining cryogenic temperatures within superconducting magnets. Hybrid Monte Carlo (MC)/deterministic techniques are necessary for this analysis because FES are large, heavily shielded, and contain streaming paths that can only be resolved with MC. The tremendous complexity of FES necessitates the use of CAD geometry for design and analysis. Previous ITER analysis has required the translation of CAD geometry to MCNP5 form in order to use the AutomateD VAriaNcemore » reducTion Generator (ADVANTG) for hybrid MC/deterministic transport. In this work, ADVANTG was modified to support CAD geometry, allowing hybrid (MC)/deterministic transport to be done automatically and eliminating the need for this translation step. This was done by adding a new ray tracing routine to ADVANTG for CAD geometries using the Direct Accelerated Geometry Monte Carlo (DAGMC) software library. This new capability is demonstrated with a prompt dose rate calculation for an ITER computational benchmark problem using both the Consistent Adjoint Driven Importance Sampling (CADIS) method an the Forward Weighted (FW)-CADIS method. The variance reduction parameters produced by ADVANTG are shown to be the same using CAD geometry and standard MCNP5 geometry. Significant speedups were observed for both neutrons (as high as a factor of 7.1) and photons (as high as a factor of 59.6).« less
NASA Astrophysics Data System (ADS)
Zapp, E.; Shelfer, T.; Semones, E.; Johnson, A.; Weyland, M.; Golightly, M.; Smith, G.; Dardano, C.
For roughly the past three decades, combinatorial geometries have been the predominant mode for the development of mass distribution models associated with the estimation of radiological risk for manned space flight. Examples of these are the MEVDP (Modified Elemental Volume Dose Program) vehicle representation of Liley and Hamilton, and the quadratic functional representation of the CAM/CAF (Computerized Anatomical Male/Female) human body models as modified by Billings and Yucker. These geometries, have the advantageous characteristics of being simple for a familiarized user to maintain, and because of the relative lack of any operating system or run-time library dependence, they are also easy to transfer from one computing platform to another. Unfortunately they are also limited in the amount of modeling detail possible, owing to the abstract geometric representation. In addition, combinatorial representations are also known to be error-prone in practice, since there is no convenient method for error identification (i.e. overlap, etc.), and extensive calculation and/or manual comparison may is often necessary to demonstrate that the geometry is adequately represented. We present an alternate approach linking materials -specific, CAD-based mass models directly to geometric analysis tools requiring no approximation with respect to materials , nor any meshing (i.e. tessellation) of the representative geometry. A new approach to ray tracing is presented which makes use of the fundamentals of the CAD representation to perform geometric analysis directly on the NURBS (Non-Uniform Rational BSpline) surfaces themselves. In this way we achieve a framework for- the rapid, precise development and analysis of materials-specific mass distribution models.
NASA Astrophysics Data System (ADS)
Ahlers, Volker; Weigl, Paul; Schachtzabel, Hartmut
2005-04-01
Due to the increasing demand for high-quality ceramic crowns and bridges, the CAD/CAM-based production of dental restorations has been a subject of intensive research during the last fifteen years. A prerequisite for the efficient processing of the 3D measurement of prepared teeth with a minimal amount of user interaction is the automatic determination of the preparation line, which defines the sealing margin between the restoration and the prepared tooth. Current dental CAD/CAM systems mostly require the interactive definition of the preparation line by the user, at least by means of giving a number of start points. Previous approaches to the automatic extraction of the preparation line rely on single contour detection algorithms. In contrast, we use a combination of different contour detection algorithms to find several independent potential preparation lines from a height profile of the measured data. The different algorithms (gradient-based, contour-based, and region-based) show their strengths and weaknesses in different clinical situations. A classifier consisting of three stages (range check, decision tree, support vector machine), which is trained by human experts with real-world data, finally decides which is the correct preparation line. In a test with 101 clinical preparations, a success rate of 92.0% has been achieved. Thus the combination of different contour detection algorithms yields a reliable method for the automatic extraction of the preparation line, which enables the setup of a turn-key dental CAD/CAM process chain with a minimal amount of interactive screen work.
Tiouririne, Mohamed; Dixon, Adam J; Mauldin, F William; Scalzo, David; Krishnaraj, Arun
2017-08-01
The aim of this study was to evaluate the imaging performance of a handheld ultrasound system and the accuracy of an automated lumbar spine computer-aided detection (CAD) algorithm in the spines of human subjects. This study was approved by the institutional review board of the University of Virginia. The authors designed a handheld ultrasound system with enhanced bone image quality and fully automated CAD of lumbar spine anatomy. The imaging performance was evaluated by imaging the lumbar spines of 68 volunteers with body mass index between 18.5 and 48 kg/m. The accuracy, sensitivity, and specificity of the lumbar spine CAD algorithm were assessed by comparing the algorithm's results to ground-truth segmentations of neuraxial anatomy provided by radiologists. The lumbar spine CAD algorithm detected the epidural space with a sensitivity of 94.2% (95% confidence interval [CI], 85.1%-98.1%) and a specificity of 85.5% (95% CI, 81.7%-88.6%) and measured its depth with an error of approximately ±0.5 cm compared with measurements obtained manually from the 2-dimensional ultrasound images. The spine midline was detected with a sensitivity of 93.9% (95% CI, 85.8%-97.7%) and specificity of 91.3% (95% CI, 83.6%-96.9%), and its lateral position within the ultrasound image was measured with an error of approximately ±0.3 cm. The bone enhancement imaging mode produced images with 5.1- to 10-fold enhanced bone contrast when compared with a comparable handheld ultrasound imaging system. The results of this study demonstrate the feasibility of CAD for assisting with real-time interpretation of ultrasound images of the lumbar spine at the bedside.
A new screening pathway for identifying asymptomatic patients using dental panoramic radiographs
NASA Astrophysics Data System (ADS)
Hayashi, Tatsuro; Matsumoto, Takuya; Sawagashira, Tsuyoshi; Tagami, Motoki; Katsumata, Akitoshi; Hayashi, Yoshinori; Muramatsu, Chisako; Zhou, Xiangrong; Iida, Yukihiro; Matsuoka, Masato; Katagi, Kiyoji; Fujita, Hiroshi
2012-03-01
To identify asymptomatic patients is the challenging task and the essential first step in diagnosis. Findings of dental panoramic radiographs include not only dental conditions but also radiographic signs that are suggestive of possible systemic diseases such as osteoporosis, arteriosclerosis, and maxillary sinusitis. Detection of such signs on panoramic radiographs has a potential to provide supplemental benefits for patients. However, it is not easy for general dental practitioners to pay careful attention to such signs. We addressed the development of a computer-aided detection (CAD) system that detects radiographic signs of pathology on panoramic images, and the design of the framework of new screening pathway by cooperation of dentists and our CAD system. The performance evaluation of our CAD system showed the sensitivity and specificity in the identification of osteoporotic patients were 92.6 % and 100 %, respectively, and those of the maxillary sinus abnormality were 89.6 % and 73.6 %, respectively. The detection rate of carotid artery calcifications that suggests the need for further medical evaluation was approximately 93.6 % with 4.4 false-positives per image. To validate the utility of the new screening pathway, preliminary clinical trials by using our CAD system were conducted. To date, 223 panoramic images were processed and 4 asymptomatic patients with suspected osteoporosis, 7 asymptomatic patients with suspected calcifications, and 40 asymptomatic patients with suspected maxillary sinusitis were detected in our initial trial. It was suggested that our new screening pathway could be useful to identify asymptomatic patients with systemic diseases.
The clinical evaluation of the CADence device in the acoustic detection of coronary artery disease.
Thomas, Joseph L; Ridner, Michael; Cole, Jason H; Chambers, Jeffrey W; Bokhari, Sabahat; Yannopoulos, Demetris; Kern, Morton; Wilson, Robert F; Budoff, Matthew J
2018-06-23
The noninvasive detection of turbulent coronary flow may enable diagnosis of significant coronary artery disease (CAD) using novel sensor and analytic technology. Eligible patients (n = 1013) with chest pain and CAD risk factors undergoing nuclear stress testing were studied using the CADence (AUM Cardiovascular Inc., Northfield MN) acoustic detection (AD) system. The trial was designed to demonstrate non-inferiority of AD for diagnostic accuracy in detecting significant CAD as compared to an objective performance criteria (sensitivity 83% and specificity 80%, with 15% non-inferiority margins) for nuclear stress testing. AD analysis was blinded to clinical, core lab-adjudicated angiographic, and nuclear data. The presence of significant CAD was determined by computed tomographic (CCTA) or invasive angiography. A total of 1013 subjects without prior coronary revascularization or Q-wave myocardial infarction were enrolled. Primary analysis was performed on subjects with complete angiographic and AD data (n = 763) including 111 subjects (15%) with severe CAD based on CCTA (n = 34) and invasive angiography (n = 77). The sensitivity and specificity of AD were 78% (p = 0.012 for non-inferiority) and 35% (p < 0.001 for failure to demonstrate non-inferiority), respectively. AD results had a high 91% negative predictive value for the presence of significant CAD. AD testing failed to demonstrate non-inferior diagnostic accuracy as compared to the historical performance of a nuclear stress OPC due to low specificity. AD sensitivity was non-inferior in detecting significant CAD with a high negative predictive value supporting a potential value in excluding CAD.
Quantitative assessment of multiple sclerosis lesion load using CAD and expert input
NASA Astrophysics Data System (ADS)
Gertych, Arkadiusz; Wong, Alexis; Sangnil, Alan; Liu, Brent J.
2008-03-01
Multiple sclerosis (MS) is a frequently encountered neurological disease with a progressive but variable course affecting the central nervous system. Outline-based lesion quantification in the assessment of lesion load (LL) performed on magnetic resonance (MR) images is clinically useful and provides information about the development and change reflecting overall disease burden. Methods of LL assessment that rely on human input are tedious, have higher intra- and inter-observer variability and are more time-consuming than computerized automatic (CAD) techniques. At present it seems that methods based on human lesion identification preceded by non-interactive outlining by CAD are the best LL quantification strategies. We have developed a CAD that automatically quantifies MS lesions, displays 3-D lesion map and appends radiological findings to original images according to current DICOM standard. CAD is also capable to display and track changes and make comparison between patient's separate MRI studies to determine disease progression. The findings are exported to a separate imaging tool for review and final approval by expert. Capturing and standardized archiving of manual contours is also implemented. Similarity coefficients calculated from quantities of LL in collected exams show a good correlation of CAD-derived results vs. those incorporated as expert's reading. Combining the CAD approach with an expert interaction may impact to the diagnostic work-up of MS patients because of improved reproducibility in LL assessment and reduced time for single MR or comparative exams reading. Inclusion of CAD-generated outlines as DICOM-compliant overlays into the image data can serve as a better reference in MS progression tracking.
CAD/CAM produces dentures with improved fit.
Steinmassl, Otto; Dumfahrt, Herbert; Grunert, Ingrid; Steinmassl, Patricia-Anca
2018-02-22
Resin polymerisation shrinkage reduces the congruence of the denture base with denture-bearing tissues and thereby decreases the retention of conventionally fabricated dentures. CAD/CAM denture manufacturing is a subtractive process, and polymerisation shrinkage is not an issue anymore. Therefore, CAD/CAM dentures are assumed to show a higher denture base congruence than conventionally fabricated dentures. It has been the aim of this study to test this hypothesis. CAD/CAM dentures provided by four different manufacturers (AvaDent, Merz Dental, Whole You, Wieland/Ivoclar) were generated from ten different master casts. Ten conventional dentures (pack and press, long-term heat polymerisation) made from the same master casts served as control group. The master casts and all denture bases were scanned and matched digitally. The absolute incongruences were measured using a 2-mm mesh. Conventionally fabricated dentures showed a mean deviation of 0.105 mm, SD = 0.019 from the master cast. All CAD/CAM dentures showed lower mean incongruences. From all CAD/CAM dentures, AvaDent Digital Dentures showed the highest congruence with the master cast surface with a mean deviation of 0.058 mm, SD = 0.005. Wieland Digital Dentures showed a mean deviation of 0.068 mm, SD = 0.005, Whole You Nexteeth prostheses showed a mean deviation of 0.074 mm, SD = 0.011 and Baltic Denture System prostheses showed a mean deviation of 0.086 mm, SD = 0.012. CAD/CAM produces dentures with better fit than conventional dentures. The present study explains the clinically observed enhanced retention and lower traumatic ulcer-frequency in CAD/CAM dentures.
The interplay of attention economics and computer-aided detection marks in screening mammography
NASA Astrophysics Data System (ADS)
Schwartz, Tayler M.; Sridharan, Radhika; Wei, Wei; Lukyanchenko, Olga; Geiser, William; Whitman, Gary J.; Haygood, Tamara Miner
2016-03-01
Introduction: According to attention economists, overabundant information leads to decreased attention for individual pieces of information. Computer-aided detection (CAD) alerts radiologists to findings potentially associated with breast cancer but is notorious for creating an abundance of false-positive marks. We suspected that increased CAD marks do not lengthen mammogram interpretation time, as radiologists will selectively disregard these marks when present in larger numbers. We explore the relevance of attention economics in mammography by examining how the number of CAD marks affects interpretation time. Methods: We performed a retrospective review of bilateral digital screening mammograms obtained between January 1, 2011 and February 28, 2014, using only weekend interpretations to decrease distractions and the likelihood of trainee participation. We stratified data according to reader and used ANOVA to assess the relationship between number of CAD marks and interpretation time. Results: Ten radiologists, with median experience after residency of 12.5 years (range 6 to 24,) interpreted 1849 mammograms. When accounting for number of images, Breast Imaging Reporting and Data System category, and breast density, increasing numbers of CAD marks was correlated with longer interpretation time only for the three radiologists with the fewest years of experience (median 7 years.) Conclusion: For the 7 most experienced readers, increasing CAD marks did not lengthen interpretation time. We surmise that as CAD marks increase, the attention given to individual marks decreases. Experienced radiologists may rapidly dismiss larger numbers of CAD marks as false-positive, having learned that devoting extra attention to such marks does not improve clinical detection.
Chao, Nan; Liu, Shu-Xin; Liu, Bing-Mei; Li, Ning; Jiang, Xiang-Ning; Gai, Ying
2014-11-01
Nine CAD/CAD-like genes in P. tomentosa were classified into four classes based on expression patterns, phylogenetic analysis and biochemical properties with modification for the previous claim of SAD. Cinnamyl alcohol dehydrogenase (CAD) functions in monolignol biosynthesis and plays a critical role in wood development and defense. In this study, we isolated and cloned nine CAD/CAD-like genes in the Populus tomentosa genome. We investigated differential expression using microarray chips and found that PtoCAD1 was highly expressed in bud, root and vascular tissues (xylem and phloem) with the greatest expression in the root. Differential expression in tissues was demonstrated for PtoCAD3, PtoCAD6 and PtoCAD9. Biochemical analysis of purified PtoCADs in vitro indicated PtoCAD1, PtoCAD2 and PtoCAD8 had detectable activity against both coniferaldehyde and sinapaldehyde. PtoCAD1 used both substrates with high efficiency. PtoCAD2 showed no specific requirement for sinapaldehyde in spite of its high identity with so-called PtrSAD (sinapyl alcohol dehydrogenase). In addition, the enzymatic activity of PtoCAD1 and PtoCAD2 was affected by temperature. We classified these nine CAD/CAD-like genes into four classes: class I included PtoCAD1, which was a bone fide CAD with the highest activity; class II included PtoCAD2, -5, -7, -8, which might function in monolignol biosynthesis and defense; class III genes included PtoCAD3, -6, -9, which have a distinct expression pattern; class IV included PtoCAD12, which has a distinct structure. These data suggest divergence of the PtoCADs and its homologs, related to their functions. We propose genes in class II are a subset of CAD genes that evolved before angiosperms appeared. These results suggest CAD/CAD-like genes in classes I and II play a role in monolignol biosynthesis and contribute to our knowledge of lignin biosynthesis in P. tomentosa.
Construction and comparative evaluation of different activity detection methods in brain FDG-PET.
Buchholz, Hans-Georg; Wenzel, Fabian; Gartenschläger, Martin; Thiele, Frank; Young, Stewart; Reuss, Stefan; Schreckenberger, Mathias
2015-08-18
We constructed and evaluated reference brain FDG-PET databases for usage by three software programs (Computer-aided diagnosis for dementia (CAD4D), Statistical Parametric Mapping (SPM) and NEUROSTAT), which allow a user-independent detection of dementia-related hypometabolism in patients' brain FDG-PET. Thirty-seven healthy volunteers were scanned in order to construct brain FDG reference databases, which reflect the normal, age-dependent glucose consumption in human brain, using either software. Databases were compared to each other to assess the impact of different stereotactic normalization algorithms used by either software package. In addition, performance of the new reference databases in the detection of altered glucose consumption in the brains of patients was evaluated by calculating statistical maps of regional hypometabolism in FDG-PET of 20 patients with confirmed Alzheimer's dementia (AD) and of 10 non-AD patients. Extent (hypometabolic volume referred to as cluster size) and magnitude (peak z-score) of detected hypometabolism was statistically analyzed. Differences between the reference databases built by CAD4D, SPM or NEUROSTAT were observed. Due to the different normalization methods, altered spatial FDG patterns were found. When analyzing patient data with the reference databases created using CAD4D, SPM or NEUROSTAT, similar characteristic clusters of hypometabolism in the same brain regions were found in the AD group with either software. However, larger z-scores were observed with CAD4D and NEUROSTAT than those reported by SPM. Better concordance with CAD4D and NEUROSTAT was achieved using the spatially normalized images of SPM and an independent z-score calculation. The three software packages identified the peak z-scores in the same brain region in 11 of 20 AD cases, and there was concordance between CAD4D and SPM in 16 AD subjects. The clinical evaluation of brain FDG-PET of 20 AD patients with either CAD4D-, SPM- or NEUROSTAT-generated databases from an identical reference dataset showed similar patterns of hypometabolism in the brain regions known to be involved in AD. The extent of hypometabolism and peak z-score appeared to be influenced by the calculation method used in each software package rather than by different spatial normalization parameters.
Challapalli, Amarnath; Barwick, Tara; Tomasi, Giampaolo; O' Doherty, Michael; Contractor, Kaiyumars; Stewart, Simon; Al-Nahhas, Adil; Behan, Kevin; Coombes, Charles; Aboagye, Eric O; Mangar, Stephen
2014-01-01
The aim of the study was to assess the effects of neoadjuvant androgen deprivation (NAD) and radical prostate radiotherapy with concurrent androgen deprivation (RT-CAD) on prostatic [C]choline kinetics and thus develop methodology for the use of [C]choline-PET/computed tomography (CT) as an early imaging biomarker. Ten patients with histologically confirmed prostate cancer underwent three sequential dynamic [C]choline-PET/CT pelvic scans: at baseline, after NAD and 4 months after RT-CAD. [C]Choline uptake was quantified using the average and maximum standardized uptake values at 60 min (SUV60,ave and SUV60,max), the tumour-to-muscle ratios (TMR60,max) and net irreversible retention of [C]choline at steady state (Kimod-pat). The combination of NAD and RT-CAD significantly decreased tumour [C]choline uptake (SUV60,ave, SUV60,max, TMR60,max or Kimod-pat) and prostate-specific antigen (PSA) levels (analysis of variance, P<0.001 for all variables). Although the magnitude of reduction in the variables was larger after NAD, there was a smaller additional reduction after RT-CAD. A wide range of reduction in tumour SUV60,ave (38-83.7%) and SUV60,max (22.2-85.3%) was seen with combined NAD and RT-CAD despite patients universally achieving PSA suppression (narrow range of 93.5-99.7%). There was good association between baseline SUV60,max and initial PSA levels (Pearson's r=0.7, P=0.04). The reduction in tumour SUV60,ave after NAD was associated with PSA reduction (r=0.7, P=0.04). This association occurred despite the larger reduction in PSA (94%) compared with SUV60,ave (58%). This feasibility study shows that [C]choline-PET/CT detects metabolic changes within tumours following NAD and RT-CAD to the prostate. A differential reduction in [C]choline uptake despite a global reduction in PSA following NAD and RT-CAD could provide prognostic information and warrants further evaluation as an imaging biomarker in this setting.
Presotto, Anna Gabriella Camacho; Bhering, Cláudia Lopes Brilhante; Mesquita, Marcelo Ferraz; Barão, Valentim Adelino Ricardo
2017-03-01
Several studies have shown the superiority of computer-assisted design and computer-assisted manufacturing (CAD-CAM) technology compared with conventional casting. However, an advanced technology exists for casting procedures (the overcasting technique), which may serve as an acceptable and affordable alternative to CAD-CAM technology for fabricating 3-unit implant-supported fixed dental prostheses (FDPs). The purpose of this in vitro study was to evaluate, using quantitative photoelastic analysis, the effect of the prosthetic framework fabrication method (CAD-CAM and overcasting) on the marginal fit and stress transmitted to implants. The correlation between marginal fit and stress was also investigated. Three-unit implant-supported FDP frameworks were made using the CAD-CAM (n=10) and overcasting (n=10) methods. The frameworks were waxed to simulate a mandibular first premolar (PM region) to first molar (M region) FDP using overcast mini-abutment cylinders. The wax patterns were overcast (overcast experimental group) or scanned to obtain the frameworks (CAD-CAM control group). All frameworks were fabricated from cobalt-chromium (CoCr) alloy. The marginal fit was analyzed according to the single-screw test protocol, obtaining an average value for each region (M and PM) and each framework. The frameworks were tightened for the photoelastic model with standardized 10-Ncm torque. Stress was measured by quantitative photoelastic analysis. The results were submitted to the Student t test, 2-way ANOVA, and Pearson correlation test (α=.05). The framework fabrication method (FM) and evaluation site (ES; M and PM regions) did not affect the marginal fit values (P=.559 for FM and P=.065 for ES) and stress (P=.685 for FM and P=.468 for ES) in the implant-supported system. Positive correlations between marginal fit and stress were observed (CAD-CAM: r=0.922; P<.001; overcast: r=0.908; P<.001). CAD-CAM and overcasting methods present similar marginal fit and stress values for 3-unit FDP frameworks. The decreased marginal fit of frameworks induces greater stress in the implant-supported system. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Computer-Aided Drafting. Education for Technology Employment.
ERIC Educational Resources Information Center
Northern Illinois Univ., De Kalb. Dept. of Technology.
This computer-aided drafting (CAD) curriculum was developed to provide drafting instructors in Illinois with a useful guide for relating an important new technological advance to the vocational classroom. The competency-based learning activity guides are written to be used with any CAD system being used at the secondary and postsecondary levels.…
Legal Medicine Information System using CDISC ODM.
Kiuchi, Takahiro; Yoshida, Ken-ichi; Kotani, Hirokazu; Tamaki, Keiji; Nagai, Hisashi; Harada, Kazuki; Ishikawa, Hirono
2013-11-01
We have developed a new database system for forensic autopsies, called the Legal Medicine Information System, using the Clinical Data Interchange Standards Consortium (CDISC) Operational Data Model (ODM). This system comprises two subsystems, namely the Institutional Database System (IDS) located in each institute and containing personal information, and the Central Anonymous Database System (CADS) located in the University Hospital Medical Information Network Center containing only anonymous information. CDISC ODM is used as the data transfer protocol between the two subsystems. Using the IDS, forensic pathologists and other staff can register and search for institutional autopsy information, print death certificates, and extract data for statistical analysis. They can also submit anonymous autopsy information to the CADS semi-automatically. This reduces the burden of double data entry, the time-lag of central data collection, and anxiety regarding legal and ethical issues. Using the CADS, various studies on the causes of death can be conducted quickly and easily, and the results can be used to prevent similar accidents, diseases, and abuse. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
ACSYNT - A standards-based system for parametric, computer aided conceptual design of aircraft
NASA Technical Reports Server (NTRS)
Jayaram, S.; Myklebust, A.; Gelhausen, P.
1992-01-01
A group of eight US aerospace companies together with several NASA and NAVY centers, led by NASA Ames Systems Analysis Branch, and Virginia Tech's CAD Laboratory agreed, through the assistance of Americal Technology Initiative, in 1990 to form the ACSYNT (Aircraft Synthesis) Institute. The Institute is supported by a Joint Sponsored Research Agreement to continue the research and development in computer aided conceptual design of aircraft initiated by NASA Ames Research Center and Virginia Tech's CAD Laboratory. The result of this collaboration, a feature-based, parametric computer aided aircraft conceptual design code called ACSYNT, is described. The code is based on analysis routines begun at NASA Ames in the early 1970's. ACSYNT's CAD system is based entirely on the ISO standard Programmer's Hierarchical Interactive Graphics System and is graphics-device independent. The code includes a highly interactive graphical user interface, automatically generated Hermite and B-Spline surface models, and shaded image displays. Numerous features to enhance aircraft conceptual design are described.
Computer aided detection system for lung cancer using computer tomography scans
NASA Astrophysics Data System (ADS)
Mahesh, Shanthi; Rakesh, Spoorthi; Patil, Vidya C.
2018-04-01
Lung Cancer is a disease can be defined as uncontrolled cell growth in tissues of the lung. If we detect the Lung Cancer in its early stage, then that could be the key of its cure. In this work the non-invasive methods are studied for assisting in nodule detection. It supplies a Computer Aided Diagnosis System (CAD) for early detection of lung cancer nodules from the Computer Tomography (CT) images. CAD system is the one which helps to improve the diagnostic performance of radiologists in their image interpretations. The main aim of this technique is to develop a CAD system for finding the lung cancer using the lung CT images and classify the nodule as Benign or Malignant. For classifying cancer cells, SVM classifier is used. Here, image processing techniques have been used to de-noise, to enhance, for segmentation and edge detection of an image is used to extract the area, perimeter and shape of nodule. The core factors of this research are Image quality and accuracy.
Yang, J; Feng, H L
2018-04-09
With the rapid development of the chair-side computer aided design and computer aided manufacture (CAD/CAM) technology, its accuracy and operability of have been greatly improved in recent years. Chair-side CAD/CAM system may produce all kinds of indirect restorations, and has the advantages of rapid, accurate and stable production. It has become the future development direction of Stomatology. This paper describes the clinical application of the chair-side CAD/CAM technology for anterior aesthetic restorations from the aspects of shade and shape.
Genetic Design Automation: engineering fantasy or scientific renewal?
Lux, Matthew W.; Bramlett, Brian W.; Ball, David A.; Peccoud, Jean
2013-01-01
Synthetic biology aims to make genetic systems more amenable to engineering, which has naturally led to the development of Computer-Aided Design (CAD) tools. Experimentalists still primarily rely on project-specific ad-hoc workflows instead of domain-specific tools, suggesting that CAD tools are lagging behind the front line of the field. Here, we discuss the scientific hurdles that have limited the productivity gains anticipated from existing tools. We argue that the real value of efforts to develop CAD tools is the formalization of genetic design rules that determine the complex relationships between genotype and phenotype. PMID:22001068
Tang, Yang; Xiong, Jun; Jiang, Han-Peng; Zheng, Shu-Jian; Feng, Yu-Qi; Yuan, Bi-Feng
2014-08-05
Cytosine methylation (5-methylcytosine, 5-mC) in DNA is an important epigenetic mark that has regulatory roles in various biological processes. In plants, active DNA demethylation can be achieved through direct cleavage by DNA glycosylases, followed by replacement of 5-mC with cytosine by base excision repair (BER) machinery. Recent studies in mammals have demonstrated 5-mC can be sequentially oxidized to 5-hydroxymethylcytosine (5-hmC), 5-formylcytosine (5-foC), and 5-carboxylcytosine (5-caC) by Ten-eleven translocation (TET) proteins. The consecutive oxidations of 5-mC constitute the active DNA demethylation pathway in mammals, which raised the possible presence of oxidation products of 5-mC (5-hmC, 5-foC, and 5-caC) in plant genomes. However, there is no definitive evidence supporting the presence of these modified bases in plant genomic DNA, especially for 5-foC and 5-caC. Here we developed a chemical derivatization strategy combined with liquid chromatography-electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method to determine 5-formyl-2'-deoxycytidine (5-fodC) and 5-carboxyl-2'-deoxycytidine (5-cadC). Derivatization of 5-fodC and 5-cadC by Girard's reagents (GirD, GirT, and GirP) significantly increased the detection sensitivities of 5-fodC and 5-cadC by 52-260-fold. Using this method, we demonstrated the widespread existence of 5-fodC and 5-cadC in genomic DNA of various plant tissues, indicating that active DNA demethylation in plants may go through an alternative pathway similar to mammals besides the pathway of direct DNA glycosylases cleavage combined with BER. Moreover, we found that environmental stresses of drought and salinity can change the contents of 5-fodC and 5-cadC in plant genomes, suggesting the functional roles of 5-fodC and 5-cadC in response to environmental stresses.
Stationary digital chest tomosynthesis for coronary artery calcium scoring
NASA Astrophysics Data System (ADS)
Wu, Gongting; Wang, Jiong; Potuzko, Marci; Harman, Allison; Pearce, Caleb; Shan, Jing; Lee, Yueh Z.; Zhou, Otto; Lu, Jianping
2016-03-01
The coronary artery calcium score (CACS) measures the buildup of calcium on the coronary artery wall and has been shown to be an important predictor of the risk of coronary artery diseases (CAD). Currently CACS is measured using CT, though the relatively high cost and high radiation dose has limited its adoption as a routine screening procedure. Digital Chest Tomosynthesis (DCT), a low dose and low cost alternative to CT, and has been shown to achieve 90% of sensitivity of CT in lung disease screening. However commercial DCT requires long scanning time and cannot be adapted for high resolution gated cardiac imaging, necessary for CACS. The stationary DCT system (s- DCT), developed in our lab, has the potential to significantly shorten the scanning time and enables high resolution cardiac gated imaging. Here we report the preliminary results of using s-DCT to estimate the CACS. A phantom heart model was developed and scanned by the s-DCT system and a clinical CT in a phantom model with realistic coronary calcifications. The adapted fan-beam volume reconstruction (AFVR) method, developed specifically for stationary tomosynthesis systems, is used to obtain high resolution tomosynthesis images. A trained cardiologist segmented out the calcifications and the CACS was obtained. We observed a strong correlation between the tomosynthesis derived CACS and CT CACS (r2 = 0.88). Our results shows s-DCT imaging has the potential to estimate CACS, thus providing a possible low cost and low dose imaging protocol for screening and monitoring CAD.
Gubern-Mérida, Albert; Vreemann, Suzan; Martí, Robert; Melendez, Jaime; Lardenoije, Susanne; Mann, Ritse M; Karssemeijer, Nico; Platel, Bram
2016-02-01
To evaluate the performance of an automated computer-aided detection (CAD) system to detect breast cancers that were overlooked or misinterpreted in a breast MRI screening program for women at increased risk. We identified 40 patients that were diagnosed with breast cancer in MRI and had a prior MRI examination reported as negative available. In these prior examinations, 24 lesions could retrospectively be identified by two breast radiologists in consensus: 11 were scored as visible and 13 as minimally visible. Additionally, 120 normal scans were collected from 120 women without history of breast cancer or breast surgery participating in the same MRI screening program. A fully automated CAD system was applied to this dataset to detect malignant lesions. At 4 false-positives per normal case, the sensitivity for the detection of cancer lesions that were visible or minimally visible in retrospect in prior-negative examinations was 0.71 (95% CI=0.38-1.00) and 0.31 (0.07-0.59), respectively. A substantial proportion of cancers that were misinterpreted or overlooked in an MRI screening program was detected by a CAD system in prior-negative examinations. It has to be clarified with further studies if such a CAD system has an influence on the number of misinterpreted and overlooked cancers in clinical practice when results are given to a radiologist. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Follak, A C; Miotti, L L; Lenzi, T L; Rocha, R O; Soares, F Z
The purpose of this study was to evaluate the influence of water storage on bond strength of multimode adhesive systems to artificially induced caries-affected dentin. One hundred twelve sound bovine incisors were randomly assigned to 16 groups (n=7) according to the dentin condition (sound; SND, artificially induced caries-affected dentin; CAD, cariogenic challenge by pH cycling for 14 days); the adhesive system (SU, Scotchbond Universal Adhesive; AB, All-Bond Universal; PB, Prime & Bond Elect; SB, Adper Single Bond 2; and CS, Clearfil SE Bond), and the etching strategy (etch-and-rinse and self-etch). All adhesive systems were applied under manufacturer's instructions to flat dentin surfaces, and a composite block was built up on each dentin surface. After 24 hours of water storage, the specimens were sectioned into stick-shaped specimens (0.8 mm 2 ) and submitted to a microtensile test immediately (24 hours) or after six months of water storage. Bond strength data (MPa) were analyzed using three-way repeated-measures analysis of variance and post hoc Tukey test (α=5%), considering each substrate separately (SND and CAD). The etching strategy did not influence the bond strength of multimode adhesives, irrespective of the dentin condition. Water storage only reduced significantly the bond strength to CAD. The degradation of bond strength due to water storage was more pronounced in CAD, regardless of the etching strategy.
A new approach of objective quality evaluation on JPEG2000 lossy-compressed lung cancer CT images
NASA Astrophysics Data System (ADS)
Cai, Weihua; Tan, Yongqiang; Zhang, Jianguo
2007-03-01
Image compression has been used to increase the communication efficiency and storage capacity. JPEG 2000 compression, based on the wavelet transformation, has its advantages comparing to other compression methods, such as ROI coding, error resilience, adaptive binary arithmetic coding and embedded bit-stream. However it is still difficult to find an objective method to evaluate the image quality of lossy-compressed medical images so far. In this paper, we present an approach to evaluate the image quality by using a computer aided diagnosis (CAD) system. We selected 77 cases of CT images, bearing benign and malignant lung nodules with confirmed pathology, from our clinical Picture Archiving and Communication System (PACS). We have developed a prototype of CAD system to classify these images into benign ones and malignant ones, the performance of which was evaluated by the receiver operator characteristics (ROC) curves. We first used JPEG 2000 to compress these cases of images with different compression ratio from lossless to lossy, and used the CAD system to classify the cases with different compressed ratio, then compared the ROC curves from the CAD classification results. Support vector machine (SVM) and neural networks (NN) were used to classify the malignancy of input nodules. In each approach, we found that the area under ROC (AUC) decreases with the increment of compression ratio with small fluctuations.
The impact of artificially caries-affected dentin on bond strength of multi-mode adhesives
Follak, Andressa Cargnelutti; Miotti, Leonardo Lamberti; Lenzi, Tathiane Larissa; Rocha, Rachel de Oliveira; Maxnuck Soares, Fabio Zovico
2018-01-01
Aim: The aim of this study is to evaluate the impact of dentin condition on bond strength of multi-mode adhesive systems (MMAS) to sound and artificially induced caries-affected dentin (CAD). Methods: Flat dentin surfaces of 112 bovine incisors were assigned to 16 subgroups (n = 7) according to the substrate condition (sound and CAD– pH-cycling for 14 days); adhesive systems (Scotchbond Universal, All-Bond Universal, Prime and Bond Elect, Adper Single Bond Plus and Clearfil SE Bond) and etching strategy (etch-and-rinse and self-etch). All systems were applied according to the manufacturer's instructions, and resin composite restorations were built. After 24 h of water storage, specimens were sectioned (0.8 mm2) and submitted to the microtensile test. Statistical Analysis: Data (MPa) were analyzed using three-way analysis of variance and Tukey's test (α = 0.05). Results: MMAS presented similar bond strength values, regardless etching strategy in each substrate condition. Bond strength values were lower when MMAS were applied to CAD in the etch-and-rinse strategy. Conclusion: The etching strategy did not influence the bond strength of MMAS to sound or CAD, considering each substrate separately. However, CAD impact negatively on bond strength of MMAS in etch-and rinse mode. PMID:29674813
Evaluation of internal fit of interim crown fabricated with CAD/CAM milling and 3D printing system.
Lee, Wan-Sun; Lee, Du-Hyeong; Lee, Kyu-Bok
2017-08-01
This study is to evaluate the internal fit of the crown manufactured by CAD/CAM milling method and 3D printing method. The master model was fabricated with stainless steel by using CNC machine and the work model was created from the vinyl-polysiloxane impression. After scanning the working model, the design software is used to design the crown. The saved STL file is used on the CAD/CAM milling method and two types of 3D printing method to produce 10 interim crowns per group. Internal discrepancy measurement uses the silicon replica method and the measured data are analyzed with One-way ANOVA to verify the statistic significance. The discrepancy means (standard deviation) of the 3 groups are 171.6 (97.4) µm for the crown manufactured by the milling system and 149.1 (65.9) and 91.1 (36.4) µm, respectively, for the crowns manufactured with the two types of 3D printing system. There was a statistically significant difference and the 3D printing system group showed more outstanding value than the milling system group. The marginal and internal fit of the interim restoration has more outstanding 3D printing method than the CAD/CAM milling method. Therefore, the 3D printing method is considered as applicable for not only the interim restoration production, but also in the dental prosthesis production with a higher level of completion.
Opium addiction in patients with coronary artery disease: a grounded theory study.
Farahani, Mansoureh A; Ghaffari, Fatemeh; Seyed Fatemi, Naiemeh
2015-01-01
There are widespread misconceptions about the positive effects of opium on coronary artery disease (CAD). Thus, we performed a study to explore the opium addiction process contributing factors among CAD patients using a grounded theory approach. The sample comprised 30 addicted CAD patients and their family members, physicians, nurses and friends. Purposive and theoretical sampling was employed; semi-structured interviews were conducted. Coding and constant comparative analysis techniques were as proposed by Strauss and Corbin (1998). The core category was 'Fighting for Survival', comprising three main themes, namely, 'the gateway', 'blowing into the fire' and 'getting stuck in the mud'. Increasing knowledge about the adverse effects of opium on the cardiovascular system would reinforce prevention and rehabilitation measures. Involving patients' family-members in addiction prevention and rehabilitation programs and referring patients to specialized rehabilitation centres could help patients quit opium. Healthcare providers (HCPs) should notice to the effects of opium consumption among CAD patients; nursing care must be holistic in nature. Although opium is stigmatised in Iran, HCPs must treat addicted CAD patients similar to other patients. Nursing students' must be aware of the negative effects of illegal drugs on CAD patients and the misconceptions regarding the positive effects thereof. Any misconceptions must be probed and clarified. Rehabilitation centres must be supervised by cardiologists and HCPs.
The Genetic Architecture of Coronary Artery Disease: Current Knowledge and Future Opportunities
Hartiala, Jaana; Schwartzman, William S.; Gabbay, Julian; Ghazalpour, Anatole; Bennett, Brian J.; Allayee, Hooman
2018-01-01
Purpose of review We provide an overview of our current understanding of the genetic architecture of coronary artery disease (CAD)and discuss areas of research that provide excellent opportunities for further exploration. Recent findings Large-scale studies in human populations, coupled with rapid advances in genetic technologies over the last decade, have clearly established the association of common genetic variation with risk of CAD. However, the effect sizes of the susceptibility alleles are for the most part modest and collectively explain only a small fraction of the overall heritability. By comparison, evidence that rare variants make a substantial contribution to risk of CAD has been somewhat disappointing thus far, suggesting that other biological mechanisms have yet to be discovered. Emerging data suggests that novel pathways involved in the development of CAD can be identified through complementary and integrative systems genetics strategies in mice or humans. There is also convincing evidence that gut bacteria play a previously unrecognized role in the development of CAD, particularly through metabolism of certain dietary nutrients that lead to proatherogenic metabolites in the circulation. Summary A major effort is now underway to functionally understand the newly discovered genetic and biological associations for CAD, which could lead to the development of potentially novel therapeutic strategies. Other important areas of investigation for understanding the pathophysiology of CAD, including epistatic interactions between genes or with either sex and environmental factors, have not been studied on a broad scope and represent additional opportunities for future studies. PMID:28130654
A Knowledge Based Approach to VLSI CAD
1983-09-01
Avail-and/or Dist ISpecial L| OI. SEICURITY CLASIIrCATION OP THIS IPA.lErllm S Daene." A KNOwLEDE BASED APPROACH TO VLSI CAD’ Louis L Steinberg and...major issues lies in building up and managing the knowledge base of oesign expertise. We expect that, as with many recent expert systems, in order to
Classroom Audio Distribution in the Postsecondary Setting: A Story of Universal Design for Learning
ERIC Educational Resources Information Center
Flagg-Williams, Joan B.; Bokhorst-Heng, Wendy D.
2016-01-01
Classroom Audio Distribution Systems (CADS) consist of amplification technology that enhances the teacher's, or sometimes the student's, vocal signal above the background noise in a classroom. Much research has supported the benefits of CADS for student learning, but most of it has focused on elementary school classrooms. This study investigated…
NASA Astrophysics Data System (ADS)
Wormanns, Dag; Fiebich, Martin; Saidi, Mustafa; Diederich, Stefan; Heindel, Walter
2001-05-01
The purpose of the study was to evaluate a computer aided diagnosis (CAD) workstation with automatic detection of pulmonary nodules at low-dose spiral CT in a clinical setting for early detection of lung cancer. Two radiologists in consensus reported 88 consecutive spiral CT examinations. All examinations were reviewed using a UNIX-based CAD workstation with a self-developed algorithm for automatic detection of pulmonary nodules. The algorithm was designed to detect nodules with at least 5 mm diameter. The results of automatic nodule detection were compared to the consensus reporting of two radiologists as gold standard. Additional CAD findings were regarded as nodules initially missed by the radiologists or as false positive results. A total of 153 nodules were detected with all modalities (diameter: 85 nodules <5mm, 63 nodules 5-9 mm, 5 nodules >= 10 mm). Reasons for failure of automatic nodule detection were assessed. Sensitivity of radiologists for nodules >=5 mm was 85%, sensitivity of CAD was 38%. For nodules >=5 mm without pleural contact sensitivity was 84% for radiologists at 45% for CAD. CAD detected 15 (10%) nodules not mentioned in the radiologist's report but representing real nodules, among them 10 (15%) nodules with a diameter $GREW5 mm. Reasons for nodules missed by CAD include: exclusion because of morphological features during region analysis (33%), nodule density below the detection threshold (26%), pleural contact (33%), segmentation errors (5%) and other reasons (2%). CAD improves detection of pulmonary nodules at spiral CT significantly and is a valuable second opinion in a clinical setting for lung cancer screening. Optimization of region analysis and an appropriate density threshold have a potential for further improvement of automatic nodule detection.
Cazelli, José Guilherme; Camargo, Gabriel Cordeiro; Kruczan, Dany David; Weksler, Clara; Felipe, Alexandre Rouge; Gottlieb, Ilan
2017-10-01
The prevalence of coronary artery disease (CAD) in valvular patients is similar to that of the general population, with the usual association with traditional risk factors. Nevertheless, the search for obstructive CAD is more aggressive in the preoperative period of patients with valvular heart disease, resulting in the indication of invasive coronary angiography (ICA) to almost all adult patients, because it is believed that coronary artery bypass surgery should be associated with valve replacement. To evaluate the prevalence of obstructive CAD and factors associated with it in adult candidates for primary heart valve surgery between 2001 and 2014 at the National Institute of Cardiology (INC) and, thus, derive and validate a predictive obstructive CAD score. Cross-sectional study evaluating 2898 patients with indication for heart surgery of any etiology. Of those, 712 patients, who had valvular heart disease and underwent ICA in the 12 months prior to surgery, were included. The P value < 0.05 was adopted as statistical significance. The prevalence of obstructive CAD was 20%. A predictive model of obstructive CAD was created from multivariate logistic regression, using the variables age, chest pain, family history of CAD, systemic arterial hypertension, diabetes mellitus, dyslipidemia, smoking, and male gender. The model showed excellent correlation and calibration (R² = 0.98), as well as excellent accuracy (ROC of 0.848; 95%CI: 0.817-0.879) and validation (ROC of 0.877; 95%CI: 0.830 - 0.923) in different valve populations. Obstructive CAD can be estimated from clinical data of adult candidates for valve repair surgery, using a simple, accurate and validated score, easy to apply in clinical practice, which may contribute to changes in the preoperative strategy of acquired heart valve surgery in patients with a lower probability of obstructive disease.
NASA Astrophysics Data System (ADS)
Litjens, G. J. S.; Barentsz, J. O.; Karssemeijer, N.; Huisman, H. J.
2012-03-01
MRI has shown to have great potential in prostate cancer localization and grading, but interpreting those exams requires expertise that is not widely available. Therefore, CAD applications are being developed to aid radiologists in detecting prostate cancer. Existing CAD applications focus on the prostate as a whole. However, in clinical practice transition zone cancer and peripheral zone cancer are considered to have different appearances. In this paper we present zone-specific CAD, in addition to an atlas based segmentation technique which includes zonal segmentation. Our CAD system consists of a detection and a classification stage. Prior to the detection stage the prostate is segmented into two zones. After segmentation features are extracted. Subsequently a likelihood map is generated on which local maxima detection is performed. For each local maximum a region is segmented. In the classification stage additional shape features are calculated, after which the regions are classified. Validation was performed on 288 data sets with MR-guided biopsy results as ground truth. Freeresponse Receiver Operating Characteristic (FROC) analysis was used for statistical evaluation. The difference between whole-prostate and zone-specific CAD was assessed using the difference between the FROCs. Our results show that evaluating the two zones separately results in an increase in performance compared to whole-prostate CAD. The FROC curves at .1, 1 and 3 false positives have a sensitivity of 0.0, 0.55 and 0.72 for whole-prostate and 0.08, 0.57 and 0.80 for zone-specific CAD. The FROC curve of the zone-specific CAD also showed significantly better performance overall (p < 0.05).
Lathia, Nina; Isogai, Pierre K; De Angelis, Carlo; Smith, Thomas J; Cheung, Matthew; Mittmann, Nicole; Hoch, Jeffrey S; Walker, Scott
2013-08-07
Febrile neutropenia is a serious toxicity of cancer chemotherapy that is usually treated in hospital. We assessed the cost-effectiveness of filgrastim and pegfilgrastim as primary prophylaxis against febrile neutropenia in diffuse large B-cell lymphoma (DLBCL) patients undergoing chemotherapy. We used a Markov model that followed patients through induction chemotherapy to compare the three prophylaxis strategies: 1) no primary prophylaxis against febrile neutropenia; 2) primary prophylaxis with 10 days of filgrastim therapy; and 3) primary prophylaxis with a single dose of pegfilgrastim. The target population was a hypothetical cohort of 64-year-old men and women with DLBCL. Data sources included published literature and current clinical practice. The analysis was conducted from a publicly funded health-care system perspective. The main outcome measures included costs, quality-adjusted life years (QALYs), and incremental cost-effectiveness ratios (ICERs). In the base-case analysis, costs associated with no primary prophylaxis, primary prophylaxis with 10 days of filgrastim, and primary prophylaxis with pegfilgrastim were CaD $7314, CaD $13947, and CaD $16290, respectively. The QALYs associated with the three strategies were 0.2004, 0.2015, and 0.2024, respectively. The ICER for the filgrastim vs no primary prophylaxis strategy was CaD $5796000 per QALY. The ICER for the pegfilgrastim vs filgrastim primary prophylaxis strategy was CaD $2611000 per QALY. All one-way sensitivity analyses yielded ICERs greater than CaD $400000 per QALY. Cost-effectiveness acceptability curves show that 20.0% of iterations are cost-effective at a willingness-to-pay threshold of CaD $1595000 for the filgrastim strategy and CaD $561000 for the pegfilgrastim strategy. Primary prophylaxis against febrile neutropenia with either filgrastim or pegfilgrastim is not cost-effective in DLBCL patients.
Automatic rectum limit detection by anatomical markers correlation.
Namías, R; D'Amato, J P; del Fresno, M; Vénere, M
2014-06-01
Several diseases take place at the end of the digestive system. Many of them can be diagnosed by means of different medical imaging modalities together with computer aided detection (CAD) systems. These CAD systems mainly focus on the complete segmentation of the digestive tube. However, the detection of limits between different sections could provide important information to these systems. In this paper we present an automatic method for detecting the rectum and sigmoid colon limit using a novel global curvature analysis over the centerline of the segmented digestive tube in different imaging modalities. The results are compared with the gold standard rectum upper limit through a validation scheme comprising two different anatomical markers: the third sacral vertebra and the average rectum length. Experimental results in both magnetic resonance imaging (MRI) and computed tomography colonography (CTC) acquisitions show the efficacy of the proposed strategy in automatic detection of rectum limits. The method is intended for application to the rectum segmentation in MRI for geometrical modeling and as contextual information source in virtual colonoscopies and CAD systems. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Nguyen, Tien Manh
1989-01-01
MT's algorithm was developed as an aid in the design of space telecommunications systems when utilized with simultaneous range/command/telemetry operations. This algorithm provides selection of modulation indices for: (1) suppression of undesired signals to achieve desired link performance margins and/or to allow for a specified performance degradation in the data channel (command/telemetry) due to the presence of undesired signals (interferers); and (2) optimum power division between the carrier, the range, and the data channel. A software program using this algorithm was developed for use with MathCAD software. This software program, called the MT program, provides the computation of optimum modulation indices for all possible cases that are recommended by the Consultative Committee on Space Data System (CCSDS) (with emphasis on the squarewave, NASA/JPL ranging system).
Computer-aided detection of early cancer in the esophagus using HD endoscopy images
NASA Astrophysics Data System (ADS)
van der Sommen, Fons; Zinger, Svitlana; Schoon, Erik J.; de With, Peter H. N.
2013-02-01
Esophageal cancer is the fastest rising type of cancer in the Western world. The recent development of High-Definition (HD) endoscopy has enabled the specialist physician to identify cancer at an early stage. Nevertheless, it still requires considerable effort and training to be able to recognize these irregularities associated with early cancer. As a first step towards a Computer-Aided Detection (CAD) system that supports the physician in finding these early stages of cancer, we propose an algorithm that is able to identify irregularities in the esophagus automatically, based on HD endoscopic images. The concept employs tile-based processing, so our system is not only able to identify that an endoscopic image contains early cancer, but it can also locate it. The identification is based on the following steps: (1) preprocessing, (2) feature extraction with dimensionality reduction, (3) classification. We evaluate the detection performance in RGB, HSI and YCbCr color space using the Color Histogram (CH) and Gabor features and we compare with other well-known features to describe texture. For classification, we employ a Support Vector Machine (SVM) and evaluate its performance using different parameters and kernel functions. In experiments, our system achieves a classification accuracy of 95.9% on 50×50 pixel tiles of tumorous and normal tissue and reaches an Area Under the Curve (AUC) of 0.990. In 22 clinical examples our algorithm was able to identify all (pre-)cancerous regions and annotate those regions reasonably well. The experimental and clinical validation are considered promising for a CAD system that supports the physician in finding early stage cancer.
Executing CLIPS expert systems in a distributed environment
NASA Technical Reports Server (NTRS)
Taylor, James; Myers, Leonard
1990-01-01
This paper describes a framework for running cooperating agents in a distributed environment to support the Intelligent Computer Aided Design System (ICADS), a project in progress at the CAD Research Unit of the Design Institute at the California Polytechnic State University. Currently, the systems aids an architectural designer in creating a floor plan that satisfies some general architectural constraints and project specific requirements. At the core of ICADS is the Blackboard Control System. Connected to the blackboard are any number of domain experts called Intelligent Design Tools (IDT). The Blackboard Control System monitors the evolving design as it is being drawn and helps resolve conflicts from the domain experts. The user serves as a partner in this system by manipulating the floor plan in the CAD system and validating recommendations made by the domain experts. The primary components of the Blackboard Control System are two expert systems executed by a modified CLIPS shell. The first is the Message Handler. The second is the Conflict Resolver. The Conflict Resolver synthesizes the suggestions made by the domain experts, which can be either CLIPS expert systems, or compiled C programs. In DEMO1, the current ICADS prototype, the CLIPS domain expert systems are Acoustics, Lighting, Structural, and Thermal; the compiled C domain experts are the CAD system and the User Interface.
Paek, Janghyun; Woo, Yi-Hyung; Kim, Hyeong-Seob; Pae, Ahran; Noh, Kwantae; Lee, Hyeonjong; Kwon, Kung-Rock
2016-12-01
The aim of this study was to determine the stability of computer-aided design and manufacturing (CAD/CAM) and prefabricated abutment by measuring removal torque before and after cyclic loading. Three types of fixture and 2 types of abutments were used. Removable torque was measured after cyclic loading for 5000 cycles between 25 and 250 N for each group. The same procedure was performed twice. First, removal torque values (Newton centimeter) were measured for stock versus custom abutments as follows: group 1: 27.17 versus 26.67, group 2: 26.27 versus 26.33, and group 3: 37.33 versus 36.67. Second removal torque values (Newton centimeter) were also measured: group 1: 23 versus 23.5, group 2: 22.5 versus 22.33, and group 3: 32.67 versus 32.5. There was no significant difference between the stock and custom abutments in either the first or second removal torque values and also no significant difference among initial tightening torque, first or second removal torque (P > 0.05). With precise control of CAD/CAM abutments, good screw joint stability can be achieved.
NASA Astrophysics Data System (ADS)
Wedeking, Gregory A.; Zierer, Joseph J.; Jackson, John R.
2010-07-01
The University of Texas, Center for Electromechanics (UT-CEM) is making a major upgrade to the robotic tracking system on the Hobby Eberly Telescope (HET) as part of theWide Field Upgrade (WFU). The upgrade focuses on a seven-fold increase in payload and necessitated a complete redesign of all tracker supporting structure and motion control systems, including the tracker bridge, ten drive systems, carriage frames, a hexapod, and many other subsystems. The cost and sensitivity of the scientific payload, coupled with the tracker system mass increase, necessitated major upgrades to personnel and hardware safety systems. To optimize kinematic design of the entire tracker, UT-CEM developed novel uses of constraints and drivers to interface with a commercially available CAD package (SolidWorks). For example, to optimize volume usage and minimize obscuration, the CAD software was exercised to accurately determine tracker/hexapod operational space needed to meet science requirements. To verify hexapod controller models, actuator travel requirements were graphically measured and compared to well defined equations of motion for Stewart platforms. To ensure critical hardware safety during various failure modes, UT-CEM engineers developed Visual Basic drivers to interface with the CAD software and quickly tabulate distance measurements between critical pieces of optical hardware and adjacent components for thousands of possible hexapod configurations. These advances and techniques, applicable to any challenging robotic system design, are documented and describe new ways to use commercially available software tools to more clearly define hardware requirements and help insure safe operation.
An image database management system for conducting CAD research
NASA Astrophysics Data System (ADS)
Gruszauskas, Nicholas; Drukker, Karen; Giger, Maryellen L.
2007-03-01
The development of image databases for CAD research is not a trivial task. The collection and management of images and their related metadata from multiple sources is a time-consuming but necessary process. By standardizing and centralizing the methods in which these data are maintained, one can generate subsets of a larger database that match the specific criteria needed for a particular research project in a quick and efficient manner. A research-oriented management system of this type is highly desirable in a multi-modality CAD research environment. An online, webbased database system for the storage and management of research-specific medical image metadata was designed for use with four modalities of breast imaging: screen-film mammography, full-field digital mammography, breast ultrasound and breast MRI. The system was designed to consolidate data from multiple clinical sources and provide the user with the ability to anonymize the data. Input concerning the type of data to be stored as well as desired searchable parameters was solicited from researchers in each modality. The backbone of the database was created using MySQL. A robust and easy-to-use interface for entering, removing, modifying and searching information in the database was created using HTML and PHP. This standardized system can be accessed using any modern web-browsing software and is fundamental for our various research projects on computer-aided detection, diagnosis, cancer risk assessment, multimodality lesion assessment, and prognosis. Our CAD database system stores large amounts of research-related metadata and successfully generates subsets of cases that match the user's desired search criteria.
Design of a dataway processor for a parallel image signal processing system
NASA Astrophysics Data System (ADS)
Nomura, Mitsuru; Fujii, Tetsuro; Ono, Sadayasu
1995-04-01
Recently, demands for high-speed signal processing have been increasing especially in the field of image data compression, computer graphics, and medical imaging. To achieve sufficient power for real-time image processing, we have been developing parallel signal-processing systems. This paper describes a communication processor called 'dataway processor' designed for a new scalable parallel signal-processing system. The processor has six high-speed communication links (Dataways), a data-packet routing controller, a RISC CORE, and a DMA controller. Each communication link operates at 8-bit parallel in a full duplex mode at 50 MHz. Moreover, data routing, DMA, and CORE operations are processed in parallel. Therefore, sufficient throughput is available for high-speed digital video signals. The processor is designed in a top- down fashion using a CAD system called 'PARTHENON.' The hardware is fabricated using 0.5-micrometers CMOS technology, and its hardware is about 200 K gates.
Implant-prosthetic rehabilitation of hemimaxillectomy defects with CAD/CAM suprastructures.
Mertens, Christian; de San Jose Gonzalez, Jose; Freudlsperger, Christian; Bodem, Jens; Krisam, Johannes; Hoffmann, Jürgen; Engel, Michael
2016-11-01
Patients with hemimaxillectomy defects after tumor surgery can alternatively be rehabilitated with dental obturators or microvascular flaps. When general medical or oncologic conditions do not permit microvascular surgery, dental obturators are the only solution, yet retention for edentulous patients is often poor. The aim of this study was to evaluate whether CAD/CAM suprastructures supported by implants placed in both residual alveolar ridges and contralateral zygomatic bone could enhance obturator stability and improve functional outcomes. Five edentulous patients with class IId hemimaxillectomy defects were included in the study. Implant-retained reconstructions were planned to support cross-arch CAD/CAM milled suprastructures. Patients had to rate their restorations on a 100-mm visual analogue scale before and after treatment. Additional evaluation was performed using the Oral Health Impact Profile (OHIP-EDENT) questionnaire. In the 5 patients, 7 conventional implants were placed in the remaining zygomatic bone and 16 in the remaining contralateral alveolar ridge. After 4 months of submerged healing, CAD/CAM suprastructures were fabricated that connected all respective implants with each other. All of the prosthetic restorations were removable and bar-retained. They all achieved good defect closure and showed significant improvements concerning general satisfaction (p = 0.0343), stability (p < 0.0001), ability to chew (p = 0.0077), esthetics (p = 0.0173) and foreign body sensation (p = 0.0207). According to the OHIP-EDENT questionnaire (p = 0.0036) the improvements were significant. During the observation period of 29.4 months, no mechanical or biological complications occurred. The CAD/CAM suprastructures improved retention in all treated patients without any complications. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
A Review of Developments in Computer-Based Systems to Image Teeth and Produce Dental Restorations
Rekow, E. Dianne; Erdman, Arthur G.; Speidel, T. Michael
1987-01-01
Computer-aided design and manufacturing (CAD/CAM) make it possible to automate the creation of dental restorations. Currently practiced techniques are described. Three automated systems currently under development are described and compared. Advances in computer-aided design and computer-aided manufacturing (CAD/CAM) provide a new option for dentistry, creating an alternative technique for producing dental restorations. It is possible to create dental restorations that are automatically produced and meet or exceed current requirements for fit and occlusion.
CAD/CAM complete dentures: a review of two commercial fabrication systems.
Kattadiyil, Mathew T; Goodacre, Charles J; Baba, Nadim Z
2013-06-01
The use of computer-aided design and computer-aided manufacturing (CAD/CAM) has become available for complete dentures through the AvaDent and Dentca systems. AvaDent uses laser scanning and computer technology. Teeth are arranged and bases formed using proprietary software.The bases are milled from prepolymerized pucks of resin. Dentca uses computer software to produce virtual maxillary and mandibular edentulous ridges, arrange the teeth and form bases. The dentures are fabricated using a conventional processing technique.
Selection of examples in case-based computer-aided decision systems
Mazurowski, Maciej A.; Zurada, Jacek M.; Tourassi, Georgia D.
2013-01-01
Case-based computer-aided decision (CB-CAD) systems rely on a database of previously stored, known examples when classifying new, incoming queries. Such systems can be particularly useful since they do not need retraining every time a new example is deposited in the case base. The adaptive nature of case-based systems is well suited to the current trend of continuously expanding digital databases in the medical domain. To maintain efficiency, however, such systems need sophisticated strategies to effectively manage the available evidence database. In this paper, we discuss the general problem of building an evidence database by selecting the most useful examples to store while satisfying existing storage requirements. We evaluate three intelligent techniques for this purpose: genetic algorithm-based selection, greedy selection and random mutation hill climbing. These techniques are compared to a random selection strategy used as the baseline. The study is performed with a previously presented CB-CAD system applied for false positive reduction in screening mammograms. The experimental evaluation shows that when the development goal is to maximize the system’s diagnostic performance, the intelligent techniques are able to reduce the size of the evidence database to 37% of the original database by eliminating superfluous and/or detrimental examples while at the same time significantly improving the CAD system’s performance. Furthermore, if the case-base size is a main concern, the total number of examples stored in the system can be reduced to only 2–4% of the original database without a decrease in the diagnostic performance. Comparison of the techniques shows that random mutation hill climbing provides the best balance between the diagnostic performance and computational efficiency when building the evidence database of the CB-CAD system. PMID:18854606
Daoulah, Amin; Elkhateeb, Osama E; Nasseri, S Ali; Al-Murayeh, Mushabab; Al-Kaabi, Salem; Lotfi, Amir; Alama, Mohamed N; Al-Faifi, Salem M; Haddara, Mamdouh; Dixon, Ciaran M; Alzahrani, Ibrahim S; Alghamdi, Abdullah A; Ahmed, Waleed; Fathey, Adnan; Haq, Ejazul; Alsheikh-Ali, Alawi A
2017-01-01
Coronary artery disease (CAD) is a leading cause of death worldwide. The association of socioeconomic status with CAD is supported by numerous epidemiological studies. Whether such factors also impact the number of diseased coronary vessels and its severity is not well established. We conducted a prospective multicentre, multi-ethnic, cross sectional observational study of consecutive patients undergoing coronary angiography (CAG) at 5 hospitals in the Kingdom of Saudi Arabia and the United Arab Emirates. Baseline demographics, socioeconomic, and clinical variables were collected for all patients. Significant CAD was defined as ≥70% luminal stenosis in a major epicardial vessel. Left main disease (LMD) was defined as ≥50% stenosis in the left main coronary artery. Multi-vessel disease (MVD) was defined as having >1 significant CAD. Of 1,068 patients (age 59 ± 13, female 28%, diabetes 56%, hypertension 60%, history of CAD 43%), 792 (74%) were from urban and remainder (26%) from rural communities. Patients from rural centres were older (61 ± 12 vs 58 ± 13), and more likely to have a history of diabetes (63 vs 54%), hypertension (74 vs 55%), dyslipidaemia (78 vs 59%), CAD (50 vs 41%) and percutaneous coronary intervention (PCI) (27 vs 21%). The two groups differed significantly in terms of income level, employment status and indication for angiography. After adjusting for baseline differences, patients living in a rural area were more likely to have significant CAD (adjusted OR 2.40 [1.47, 3.97]), MVD (adjusted OR 1.76 [1.18, 2.63]) and LMD (adjusted OR 1.71 [1.04, 2.82]). Higher income was also associated with a higher risk for significant CAD (adjusted OR 6.97 [2.30, 21.09]) and MVD (adjusted OR 2.49 [1.11, 5.56]), while unemployment was associated with a higher risk of significant CAD (adjusted OR 2.21, [1.27, 3.85]). Communal and socioeconomic factors are associated with higher odds of significant CAD and MVD in the group of patients referred for CAG. The underpinnings of these associations ( e.g. pathophysiologic factors, access to care, and system-wide determinants of quality) require further study.
Shechter, Michael; Shalmon, Guy; Scheinowitz, Mickey; Koren-Morag, Nira; Feinberg, Micha S; Harats, Dror; Sela, Ben Ami; Sharabi, Yehonatan; Chouraqui, Pierre
2011-05-01
Although coffee is a widely used, pharmacologically active beverage, its impact on the cardiovascular system is controversial. To explore the effect of acute caffeine ingestion on brachial artery flow-mediated dilation (FMD) in subjects without coronary artery disease (CAD; controls) and patients with CAD, we prospectively assessed brachial artery FMD in 40 controls and 40 age- and gender-matched patients with documented stable CAD on 2 separate mornings 1 week to 2 weeks apart. After overnight fasting, discontinuation of all medications for ≥12 hours, and absence of caffeine for >48 hours, participants received capsules with caffeine 200 mg or placebo. One hour after drug ingestion, participants underwent brachial artery FMD and nitroglycerin-mediated dilation (NTG) using high-resolution ultrasound. As expected, patients with CAD were more often diabetic, hypertensive, obese, dyslipidemic, and smoked more than controls (p <0.01 for all comparisons). Aspirin, Clopidogrel, angiotensin-converting enzyme inhibitors, β blockers, and statins were significantly more common in patients with CAD than in controls (p <0.01 for all comparisons). At baseline, FMD, but not NTG, was significantly lower in patients with CAD compared to controls. Acute caffeine ingestion significantly increased FMD (patients with CAD 5.6 ± 5.0% vs 14.6 ± 5.0%, controls 8.4 ± 2.9% vs 18.6 ± 6.8%, p <0.001 for all comparisons) but not NTG (patients with CAD 13.0 ± 5.2% vs 13.8 ± 6.1%, controls 12.9 ± 3.9% vs 13.9 ± 5.8%, p = NS for all comparisons) and significantly decreased high-sensitivity C-reactive protein (patients with CAD 2.6 ± 1.4 vs 1.4 ± 1.2 mg/L, controls 3.4 ± 3.0 vs 1.2 ± 1.0 mg/L, p <0.001 for all comparisons) in the 2 groups compared to placebo. In conclusion, acute caffeine ingestion significantly improved endothelial function assessed by brachial artery FMD in subjects with and without CAD and was associated with lower plasma markers of inflammation. Copyright © 2011 Elsevier Inc. All rights reserved.
Han, Yaling; Chen, Jiyan; Qiu, Miaohan; Li, Yi; Li, Jing; Feng, Yingqing; Qiu, Jian; Meng, Liang; Sun, Yihong; Tao, Guizhou; Wu, Zhaohui; Yang, Chunyu; Guo, Jincheng; Pu, Kui; Chen, Shaoliang; Wang, Xiaozeng
2018-06-05
The prognosis of patients with coronary artery disease (CAD) at hospital discharge was constantly varying, and post-discharge risk of ischemic events remain a concern. However, risk prediction tools to identify risk of ischemia for these patients has not yet been reported. We sought to develop a scoring system for predicting long-term ischemic events in CAD patients receiving antiplatelet therapy that would be beneficial in appropriate personalized decision-making for these patients. In this prospective Optimal antiPlatelet Therapy for Chinese patients with Coronary Artery Disease (OPT-CAD, NCT01735305) registry, a total of 14,032 patients with CAD receiving at least one kind of antiplatelet agent were enrolled from 107 centers across China, from January 2012 to March 2014. The risk scoring system was developed in a derivation cohort (enrolled initially 10,000 patients in the database) using a logistic regression model and was subsequently tested in a validation cohort (the last 4,032 patients). Points in risk score was assigned based on the multivariable odds ratio of each factor. Ischemic events were defined as the composite of cardiac death, myocardial infarction or stroke. Ischemic events occurred in 342 (3.4%) patients in the derivation cohort and 160 (4.0%) patients in the validation cohort during 1-year follow-up. The OPT-CAD score, ranging from 0-257 points, consist of 10 independent risk factors, including age (0-71 points), heart rates (0-36 points), hypertension (0-20 points), prior myocardial infarction (16 points), prior stroke (16 points), renal insufficient (21 points), anemia (19 points), low ejection fraction (22 points), positive cardiac troponin (23 points) and ST-segment deviation (13 points). In predicting 1-year ischemic events, the area under receiver operating characteristics curve were 0.73 and 0.72 in derivation and validation cohort, respectively. The incidences of ischemic events in low- (0-90 points), medium- (91-150 points) and high-risk (≥151 points) patients were 1.6%, 5.5%, and 15.0%, respectively. Compared to GRACE score, OPT-CAD score had a better discrimination in predicting ischemic events and all-cause mortality (ischemic events: 0.72 vs 0.65, all-cause mortality: 0.79 vs 0.72, both P<0.001). Among CAD patients, a risk score based on 10 baseline clinical variables performed better than the GRACE risk score in predicting long-term ischemic events. However, further research is needed to assess the value of the OPT-CAD score in guiding the management of antiplatelet therapy for patients with CAD. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
High frame rate imaging systems developed in Northwest Institute of Nuclear Technology
NASA Astrophysics Data System (ADS)
Li, Binkang; Wang, Kuilu; Guo, Mingan; Ruan, Linbo; Zhang, Haibing; Yang, Shaohua; Feng, Bing; Sun, Fengrong; Chen, Yanli
2007-01-01
This paper presents high frame rate imaging systems developed in Northwest Institute of Nuclear Technology in recent years. Three types of imaging systems are included. The first type of system utilizes EG&G RETICON Photodiode Array (PDA) RA100A as the image sensor, which can work at up to 1000 frame per second (fps). Besides working continuously, the PDA system is also designed to switch to capture flash light event working mode. A specific time sequence is designed to satisfy this request. The camera image data can be transmitted to remote area by coaxial or optic fiber cable and then be stored. The second type of imaging system utilizes PHOTOBIT Complementary Metal Oxygen Semiconductor (CMOS) PB-MV13 as the image sensor, which has a high resolution of 1280 (H) ×1024 (V) pixels per frame. The CMOS system can operate at up to 500fps in full frame and 4000fps partially. The prototype scheme of the system is presented. The third type of imaging systems adopts charge coupled device (CCD) as the imagers. MINTRON MTV-1881EX, DALSA CA-D1 and CA-D6 camera head are used in the systems development. The features comparison of the RA100A, PB-MV13, and CA-D6 based systems are given in the end.
Shrivastava, Vimal K; Londhe, Narendra D; Sonawane, Rajendra S; Suri, Jasjit S
2015-10-01
A large percentage of dermatologist׳s decision in psoriasis disease assessment is based on color. The current computer-aided diagnosis systems for psoriasis risk stratification and classification lack the vigor of color paradigm. The paper presents an automated psoriasis computer-aided diagnosis (pCAD) system for classification of psoriasis skin images into psoriatic lesion and healthy skin, which solves the two major challenges: (i) fulfills the color feature requirements and (ii) selects the powerful dominant color features while retaining high classification accuracy. Fourteen color spaces are discovered for psoriasis disease analysis leading to 86 color features. The pCAD system is implemented in a support vector-based machine learning framework where the offline image data set is used for computing machine learning offline color machine learning parameters. These are then used for transformation of the online color features to predict the class labels for healthy vs. diseased cases. The above paradigm uses principal component analysis for color feature selection of dominant features, keeping the original color feature unaltered. Using the cross-validation protocol, the above machine learning protocol is compared against the standalone grayscale features with 60 features and against the combined grayscale and color feature set of 146. Using a fixed data size of 540 images with equal number of healthy and diseased, 10 fold cross-validation protocol, and SVM of polynomial kernel of type two, pCAD system shows an accuracy of 99.94% with sensitivity and specificity of 99.93% and 99.96%. Using a varying data size protocol, the mean classification accuracies for color, grayscale, and combined scenarios are: 92.85%, 93.83% and 93.99%, respectively. The reliability of the system in these three scenarios are: 94.42%, 97.39% and 96.00%, respectively. We conclude that pCAD system using color space alone is compatible to grayscale space or combined color and grayscale spaces. We validated our pCAD system against facial color databases and the results are consistent in accuracy and reliability. Copyright © 2015 Elsevier Ltd. All rights reserved.
Wang, Arthur; Santarelli, Justin G; Stiefel, Michael F
2016-12-01
Optimal management of extracranial carotid artery dissections (eCAD) in pediatric patients is not well documented, and endovascular interventions are rarely reported. A 10-year-old girl sustained multiple systemic injuries in a motor vehicle accident, including an eCAD with pseudoaneurysm. She initially failed both aspirin and endovascular stenting with progressive enlargement of a traumatic cervical carotid pseudoaneurysm and stenosis. Second-stage endovascular stent placement with coiling resulted in successful occlusion of the pseudoaneurysm. At 30-month imaging follow-up, the parent vessel remained patent with no evidence of the pseudoaneurysm. In the setting of poly-trauma, management of eCAD can be complex especially in the pediatric population. There is little data on the endovascular treatment of eCAD in children. Failed endovascular therapies are extremely rare. Our report supports surveillance imaging as repeat endovascular treatment may be necessary.
Gupta, V
2014-03-01
Cold agglutination disease (CAD) is characterized by an auto-antibody which is able to agglutinate red blood cells (RBCs) at temperatures lower than that of the body, and subsequently to activate the complement system responsible for lysis of RBCs. Patients show hemolytic anemia of varying degrees of severity, which arise or worsen upon exposure to low temperatures. We describe a case who presented with fever and symptoms of asthenia. His investigations yielded bizarre RBC parameters which led to suspicion of a rare CAD, which was confirmed on reviewing RBC parameters, peripheral smear and direct Coomb's test at different temperatures. Hence, we suggest assessment of bizarre RBC parameters and peripheral smear can help in laboratory testing and diagnosis of CAD. It should also not pose embarrassment in laboratory testing to the pathologist for making an early and accurate diagnosis, thus emphasizing the need for an early treatment of CAD.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Allard, S.M.; Albert, N.F.
1992-09-18
Cost estimates for USMC SINCGARS usage of BB-5590/U Lithium Sulfur Dioxide (LiSO[sub 2]) Batteries, BA-590/U Sealed Lead-Acid Batteries, and BB-490/U Nickel-Cadmium (Ni-Cad) Batteries. Estimates encompass battery costs, charger costs as applicable, and disposal costs. Annual battery-related costs were estimated for USMC usage of mix of LiSO[sub 2] and Ni-Cad batteries ranging from 100% use of LiSO[sub 2] batteries to 100% use of Ni-Cad batteries; and for mix of LiSO[sub 2] and Lead-Acid batteries over the same range. Estimated hourly battery-related costs are $2.66 per hour for LiSO[sub 2] batteries $0.34 for Ni-Cad batteries, and $0.30 for Lead-Acid batteries. Disposal relatedmore » regulations and related documents are discussed and included in Appendices.« less
Genetic design automation: engineering fantasy or scientific renewal?
Lux, Matthew W; Bramlett, Brian W; Ball, David A; Peccoud, Jean
2012-02-01
The aim of synthetic biology is to make genetic systems more amenable to engineering, which has naturally led to the development of computer-aided design (CAD) tools. Experimentalists still primarily rely on project-specific ad hoc workflows instead of domain-specific tools, which suggests that CAD tools are lagging behind the front line of the field. Here, we discuss the scientific hurdles that have limited the productivity gains anticipated from existing tools. We argue that the real value of efforts to develop CAD tools is the formalization of genetic design rules that determine the complex relationships between genotype and phenotype. Copyright © 2011 Elsevier Ltd. All rights reserved.
Architecture for distributed design and fabrication
NASA Astrophysics Data System (ADS)
McIlrath, Michael B.; Boning, Duane S.; Troxel, Donald E.
1997-01-01
We describe a flexible, distributed system architecture capable of supporting collaborative design and fabrication of semi-conductor devices and integrated circuits. Such capabilities are of particular importance in the development of new technologies, where both equipment and expertise are limited. Distributed fabrication enables direct, remote, physical experimentation in the development of leading edge technology, where the necessary manufacturing resources are new, expensive, and scarce. Computational resources, software, processing equipment, and people may all be widely distributed; their effective integration is essential in order to achieve the realization of new technologies for specific product requirements. Our architecture leverages is essential in order to achieve the realization of new technologies for specific product requirements. Our architecture leverages current vendor and consortia developments to define software interfaces and infrastructure based on existing and merging networking, CIM, and CAD standards. Process engineers and product designers access processing and simulation results through a common interface and collaborate across the distributed manufacturing environment.
Clustering microcalcifications techniques in digital mammograms
NASA Astrophysics Data System (ADS)
Díaz, Claudia. C.; Bosco, Paolo; Cerello, Piergiorgio
2008-11-01
Breast cancer has become a serious public health problem around the world. However, this pathology can be treated if it is detected in early stages. This task is achieved by a radiologist, who should read a large amount of mammograms per day, either for a screening or diagnostic purpose in mammography. However human factors could affect the diagnosis. Computer Aided Detection is an automatic system, which can help to specialists in the detection of possible signs of malignancy in mammograms. Microcalcifications play an important role in early detection, so we focused on their study. The two mammographic features that indicate the microcalcifications could be probably malignant are small size and clustered distribution. We worked with density techniques for automatic clustering, and we applied them on a mammography CAD prototype developed at INFN-Turin, Italy. An improvement of performance is achieved analyzing images from a Perugia-Assisi Hospital, in Italy.
APJ receptor A445C gene polymorphism in Turkish patients with coronary artery disease
Akcılar, Raziye; Yümün, Gündüz; Bayat, Zeynep; Donbaloğlu, Okan; Erselcan, Kubilay; Ece, Ezgi; Kökdaşgil, Hülya; Genç, Osman
2015-01-01
Coronary artery disease (CAD) is a disease in which a waxy substance called plaque builds up inside the coronary arteries. Apelin is a novel endogenous peptide with inotropic and vasodilatory properties and is the ligand for the angiotensin receptor-like 1 (APJ) receptor. We aimed to determine genotype and allele frequencies of APJ receptor A445C gene polymorphism in Turkish patients with CAD and healthy controls by RFLP-PCR. This study was performed on 159 unrelated CAD patients and 62 healthy controls. We obtained AA, AC and CC genotype frequencies in CAD patients as 41.5%, 49.1% and 9.4%, respectively. In the control group, frequencies of genotypes were found as 35.5% for AA, 48.4% for AC and 16.1% for CC. We did not observe difference in APJ receptor A445C polymorphism between CAD patients and healthy controls (χ2 = 2.178; df = 2; P = 0.336). The A allele was encountered in 66% (210) of the CAD and 59.7% (74) of the controls. The C allele was seen in 34% (108) of the CAD and 40.3% (50) of the controls. Allele frequencies of interested genes were not significantly different between groups (χ2 = 1.57; df = 1; p = 0.225). The frequencies of APJ receptor A445C genotype were not significantly different between control and patients. None of the three APJ receptor A445C genotypes, AA, AC and CC displayed significant difference in CAD patients. We did not find any difference in the clinical parameters except for weight and diastolic blood pressure levels in the AA, AC and CC genotypes of patients. Individuals with CC genotypes had significantly higher weight, systolic and diastolic blood pressure levels and systolic blood pressure than other genotypes, P ≤ 0.05. In addition, HDL-C level was found decreased, but this reduction was not statistically significant. Contrarily, the low levels of weight, SBP, DBP and TC were statistically significant in the subjects with AA genotype in CAD. In conclusion, CC genotype carriers may have more risk than other genotypes in the development of hypertension in CAD, but not AAgenotype carriers. We suggest that this polymorphism may not be a marker of CAD, but it may cause useful in function of the apelin/APJ system and may be a genetic predisposing factor for diagnostic processes and can be helpfull in finding new treatment strategies. We think that it is required to further comprehensive studies in order to make clear this situation in CAD. PMID:26770497
Deep neural network-based computer-assisted detection of cerebral aneurysms in MR angiography.
Nakao, Takahiro; Hanaoka, Shouhei; Nomura, Yukihiro; Sato, Issei; Nemoto, Mitsutaka; Miki, Soichiro; Maeda, Eriko; Yoshikawa, Takeharu; Hayashi, Naoto; Abe, Osamu
2018-04-01
The usefulness of computer-assisted detection (CAD) for detecting cerebral aneurysms has been reported; therefore, the improved performance of CAD will help to detect cerebral aneurysms. To develop a CAD system for intracranial aneurysms on unenhanced magnetic resonance angiography (MRA) images based on a deep convolutional neural network (CNN) and a maximum intensity projection (MIP) algorithm, and to demonstrate the usefulness of the system by training and evaluating it using a large dataset. Retrospective study. There were 450 cases with intracranial aneurysms. The diagnoses of brain aneurysms were made on the basis of MRA, which was performed as part of a brain screening program. Noncontrast-enhanced 3D time-of-flight (TOF) MRA on 3T MR scanners. In our CAD, we used a CNN classifier that predicts whether each voxel is inside or outside aneurysms by inputting MIP images generated from a volume of interest (VOI) around the voxel. The CNN was trained in advance using manually inputted labels. We evaluated our method using 450 cases with intracranial aneurysms, 300 of which were used for training, 50 for parameter tuning, and 100 for the final evaluation. Free-response receiver operating characteristic (FROC) analysis. Our CAD system detected 94.2% (98/104) of aneurysms with 2.9 false positives per case (FPs/case). At a sensitivity of 70%, the number of FPs/case was 0.26. We showed that the combination of a CNN and an MIP algorithm is useful for the detection of intracranial aneurysms. 4 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:948-953. © 2017 International Society for Magnetic Resonance in Medicine.
Automated CD-SEM recipe creation technology for mass production using CAD data
NASA Astrophysics Data System (ADS)
Kawahara, Toshikazu; Yoshida, Masamichi; Tanaka, Masashi; Ido, Sanyu; Nakano, Hiroyuki; Adachi, Naokaka; Abe, Yuichi; Nagatomo, Wataru
2011-03-01
Critical Dimension Scanning Electron Microscope (CD-SEM) recipe creation needs sample preparation necessary for matching pattern registration, and recipe creation on CD-SEM using the sample, which hinders the reduction in test production cost and time in semiconductor manufacturing factories. From the perspective of cost reduction and improvement of the test production efficiency, automated CD-SEM recipe creation without the sample preparation and the manual operation has been important in the production lines. For the automated CD-SEM recipe creation, we have introduced RecipeDirector (RD) that enables the recipe creation by using Computer-Aided Design (CAD) data and text data that includes measurement information. We have developed a system that automatically creates the CAD data and the text data necessary for the recipe creation on RD; and, for the elimination of the manual operation, we have enhanced RD so that all measurement information can be specified in the text data. As a result, we have established an automated CD-SEM recipe creation system without the sample preparation and the manual operation. For the introduction of the CD-SEM recipe creation system using RD to the production lines, the accuracy of the pattern matching was an issue. The shape of design templates for the matching created from the CAD data was different from that of SEM images in vision. Thus, a development of robust pattern matching algorithm that considers the shape difference was needed. The addition of image processing of the templates for the matching and shape processing of the CAD patterns in the lower layer has enabled the robust pattern matching. This paper describes the automated CD-SEM recipe creation technology for the production lines without the sample preparation and the manual operation using RD applied in Sony Semiconductor Kyusyu Corporation Kumamoto Technology Center (SCK Corporation Kumamoto TEC).
Kim, Jae-Hong; Oh, Seunghan; Uhm, Soo-Hyuk
2016-01-01
The aim of this study is to quantify the effect of the crystallization process on lithium disilicate ceramic crowns fabricated using a computer-aided design/computer-aided manufacturing (CAD/CAM) system and to determine whether the effect of crystallization is clinically acceptable by comparing values of fit before and after the crystallization process. The mandibular right first molar was selected as the abutment for the experiments. Fifteen working models were prepared. Lithium disilicate crowns appropriate for each abutment were prepared using a commercial CAD/CAM system. Gaps in the marginal area and 4 internal areas of each crown were measured twice-before and after crystallization-using the silicone replica technique. The mean values of fit before and after crystallization were analyzed using a paired t-test to examine whether the conversion that occurred during crystallization affected marginal and internal gaps (α = 0.05). Gaps increased in the marginal area and decreased in the internal areas after crystallization. There were statistically significant differences in all of the investigated areas (P < 0.05). None of the values for marginal and internal fit of lithium disilicate CAD/CAM crowns after crystallization exceeded 120 μm, which is the clinically acceptable threshold.
Yu, Q
2018-04-09
Computer aided design and computer aided manufacture (CAD/CAM) technology is a kind of oral digital system which is applied to clinical diagnosis and treatment. It overturns the traditional pattern, and provides a solution to restore defect tooth quickly and efficiently. In this paper we mainly discuss the clinical skills of chair-side CAD/CAM system, including tooth preparation, digital impression, the three-dimensional design of prosthesis, numerical control machining, clinical bonding and so on, and review the outcomes of several common kinds of materials at the same time.
Sailer, Irena; Benic, Goran I; Fehmer, Vincent; Hämmerle, Christoph H F; Mühlemann, Sven
2017-07-01
Clinical studies are needed to evaluate the entire digital and conventional workflows in prosthetic dentistry. The purpose of the second part of this clinical study was to compare the laboratory production time for tooth-supported single crowns made with 4 different digital workflows and 1 conventional workflow and to compare these crowns clinically. For each of 10 participants, a monolithic crown was fabricated in lithium disilicate-reinforced glass ceramic (IPS e.max CAD). The computer-aided design and computer-aided manufacturing (CAD-CAM) systems were Lava C.O.S. CAD software and centralized CAM (group L), Cares CAD software and centralized CAM (group iT), Cerec Connect CAD software and lab side CAM (group CiL), and Cerec Connect CAD software with centralized CAM (group CiD). The conventional fabrication (group K) included a wax pattern of the crown and heat pressing according to the lost-wax technique (IPS e.max Press). The time for the fabrication of the casts and the crowns was recorded. Subsequently, the crowns were clinically evaluated and the corresponding treatment times were recorded. The Paired Wilcoxon test with the Bonferroni correction was applied to detect differences among treatment groups (α=.05). The total mean (±standard deviation) active working time for the dental technician was 88 ±6 minutes in group L, 74 ±12 minutes in group iT, 74 ±5 minutes in group CiL, 92 ±8 minutes in group CiD, and 148 ±11 minutes in group K. The dental technician spent significantly more working time for the conventional workflow than for the digital workflows (P<.001). No statistically significant differences were found between group L and group CiD or between group iT and group CiL. No statistical differences in time for the clinical evaluation were found among groups, indicating similar outcomes (P>.05). Irrespective of the CAD-CAM system, the overall laboratory working time for a digital workflow was significantly shorter than for the conventional workflow, since the dental technician needed less active working time. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Lourenço, Ana M; Schmidt, Vanessa; São Braz, Berta; Nóbrega, Diana; Nunes, Telmo; Duarte-Correia, José H; Matias, Daniela; Maruhashi, Emi; Rème, Christophe A; Nuttall, Tim
2016-04-01
Long-term remission between flares of canine atopic dermatitis (CAD) can be difficult to achieve. Therefore, additional strategic forms of treatment are needed in order to target flare prevention. The concept of proactive therapy is recommended in the European guidelines for the treatment of human atopic eczema. To evaluate the efficacy of a proactive treatment regimen with a 0.0584% hydrocortisone aceponate (HCA) spray for CAD. Client-owned dogs with spontaneous atopic dermatitis (AD) (n = 41). This pilot study was conducted as a randomised, placebo-controlled, double-blinded clinical trial with an end-point of treatment failure. Dogs were treated once daily to remission, then randomly assigned to receive either the HCA spray (n = 21) or a placebo (n = 20) spray on two consecutive days each week. All dogs were on appropriate flea control. No topical or systemic anti-inflammatory or antimicrobial agents were permitted. Intention-to-treat analysis was used. At Day 0, all the dogs were in remission or had mild AD based on their Canine Atopic Dermatitis Extent and Severity Index, version 3 (CADESI-03) scores. The time to relapse was significantly higher in the HCA group (median 115 d; range 31-260 d) compared to the placebo group (median 33 d; range 15-61 d) (P < 0.0001). No adverse events were attributable to the HCA spray. Four dogs were lost to follow-up and four were withdrawn after receiving prohibited medication. These results indicate that proactive long-term therapy of CAD with an HCA spray administered on two consecutive days each week is effective and well-tolerated. © 2016 ESVD and ACVD.
NASA Astrophysics Data System (ADS)
Boehm, Holger F.; Fischer, Tanja; Riosk, Dororthea; Britsch, Stefanie; Reiser, Maximilian
2008-03-01
With an estimated life-time-risk of about 10%, breast cancer is the most common cancer among women in western societies. Extensive mammography-screening programs have been implemented for diagnosis of the disease at an early stage. Several algorithms for computer-aided detection (CAD) have been proposed to help radiologists manage the increasing number of mammographic image-data and identify new cases of cancer. However, a major issue with most CAD-solutions is the fact that performance strongly depends on the structure and density of the breast tissue. Prior information about the global tissue quality in a patient would be helpful for selecting the most effective CAD-approach in order to increase the sensitivity of lesion-detection. In our study, we propose an automated method for textural evaluation of digital mammograms using the Minkowski Functionals in 2D. 80 mammograms are consensus-classified by two experienced readers as fibrosis, involution/atrophy, or normal. For each case, the topology of graylevel distribution is evaluated within a retromamillary image-section of 512 x 512 pixels. In addition, we obtain parameters from the graylevel-histogram (20th percentile, median and mean graylevel intensity). As a result, correct classification of the mammograms based on the densitometic parameters is achieved in between 38 and 48%, whereas topological analysis increases the rate to 83%. The findings demonstrate the effectiveness of the proposed algorithm. Compared to features obtained from graylevel histograms and comparable studies, we draw the conclusion that the presented method performs equally good or better. Our future work will be focused on the characterization of the mammographic tissue according to the Breast Imaging Reporting and Data System (BI-RADS). Moreover, other databases will be tested for an in-depth evaluation of the efficiency of our proposal.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Setio, Arnaud A. A., E-mail: arnaud.arindraadiyoso@radboudumc.nl; Jacobs, Colin; Gelderblom, Jaap
Purpose: Current computer-aided detection (CAD) systems for pulmonary nodules in computed tomography (CT) scans have a good performance for relatively small nodules, but often fail to detect the much rarer larger nodules, which are more likely to be cancerous. We present a novel CAD system specifically designed to detect solid nodules larger than 10 mm. Methods: The proposed detection pipeline is initiated by a three-dimensional lung segmentation algorithm optimized to include large nodules attached to the pleural wall via morphological processing. An additional preprocessing is used to mask out structures outside the pleural space to ensure that pleural and parenchymalmore » nodules have a similar appearance. Next, nodule candidates are obtained via a multistage process of thresholding and morphological operations, to detect both larger and smaller candidates. After segmenting each candidate, a set of 24 features based on intensity, shape, blobness, and spatial context are computed. A radial basis support vector machine (SVM) classifier was used to classify nodule candidates, and performance was evaluated using ten-fold cross-validation on the full publicly available lung image database consortium database. Results: The proposed CAD system reaches a sensitivity of 98.3% (234/238) and 94.1% (224/238) large nodules at an average of 4.0 and 1.0 false positives/scan, respectively. Conclusions: The authors conclude that the proposed dedicated CAD system for large pulmonary nodules can identify the vast majority of highly suspicious lesions in thoracic CT scans with a small number of false positives.« less
NASA Astrophysics Data System (ADS)
Meijs, M.; Debats, O.; Huisman, H.
2015-03-01
In prostate cancer, the detection of metastatic lymph nodes indicates progression from localized disease to metastasized cancer. The detection of positive lymph nodes is, however, a complex and time consuming task for experienced radiologists. Assistance of a two-stage Computer-Aided Detection (CAD) system in MR Lymphography (MRL) is not yet feasible due to the large number of false positives in the first stage of the system. By introducing a multi-structure, multi-atlas segmentation, using an affine transformation followed by a B-spline transformation for registration, the organ location is given by a mean density probability map. The atlas segmentation is semi-automatically drawn with ITK-SNAP, using Active Contour Segmentation. Each anatomic structure is identified by a label number. Registration is performed using Elastix, using Mutual Information and an Adaptive Stochastic Gradient optimization. The dataset consists of the MRL scans of ten patients, with lymph nodes manually annotated in consensus by two expert readers. The feature map of the CAD system consists of the Multi-Atlas and various other features (e.g. Normalized Intensity and multi-scale Blobness). The voxel-based Gentleboost classifier is evaluated using ROC analysis with cross validation. We show in a set of 10 studies that adding multi-structure, multi-atlas anatomical structure likelihood features improves the quality of the lymph node voxel likelihood map. Multiple structure anatomy maps may thus make MRL CAD more feasible.
NASA Astrophysics Data System (ADS)
Deshpande, Ruchi R.; Fernandez, James; Lee, Joon K.; Chan, Tao; Liu, Brent J.; Huang, H. K.
2010-03-01
Timely detection of Acute Intra-cranial Hemorrhage (AIH) in an emergency environment is essential for the triage of patients suffering from Traumatic Brain Injury. Moreover, the small size of lesions and lack of experience on the reader's part could lead to difficulties in the detection of AIH. A CT based CAD algorithm for the detection of AIH has been developed in order to improve upon the current standard of identification and treatment of AIH. A retrospective analysis of the algorithm has already been carried out with 135 AIH CT studies with 135 matched normal head CT studies from the Los Angeles County General Hospital/ University of Southern California Hospital System (LAC/USC). In the next step, AIH studies have been collected from Walter Reed Army Medical Center, and are currently being processed using the AIH CAD system as part of implementing a multi-site assessment and evaluation of the performance of the algorithm. The sensitivity and specificity numbers from the Walter Reed study will be compared with the numbers from the LAC/USC study to determine if there are differences in the presentation and detection due to the difference in the nature of trauma between the two sites. Simultaneously, a stand-alone system with a user friendly GUI has been developed to facilitate implementation in a clinical setting.
Jaworski, Rafał; Jankowska, Ewa A; Ponikowski, Piotr; Banasiak, Waldemar
2012-01-01
Treatment of coronary artery disease (CAD) generates the major part of public health expenditure in the developed countries. The aim of the study was to estimate costs associated with the diagnosis and treatment of patients with CAD in Poland. Costs were estimated in a representative sample of 2593 patients with CAD receiving general practitioner (n = 1977) or specialist care (n = 616) in 2005 (the multicenter RECENT study). Data from the National Health Fund, Social Insurance Institution, Central Statistical Office, and current literature were used. The total annual cost of CAD reached €2254.17 per patient, with 48% accounting for direct medical costs (drugs, medical consultations, laboratory tests, diagnostic procedures, invasive treatment, hospitalizations, emergency care) and 52% for indirect costs (related to absence at work and disability). Eighty-one percent of total direct medical costs were covered by the public payer (including 30% of pharmacological treatment costs). Direct medical costs covered by the public payer were higher in men and in patients with more severe angina symptoms (both P <0.05). In the model based on the lowest prevalence of CAD (estimated based on the real population of patients treated in 2005), direct medical costs covered by the public payer reached €617.6 million, i.e., around 7% of the total public health expenditure in Poland in 2005. Modern management of CAD imposes enormous economic burden on the public health system in Poland. There is a need to develop and implement strategies that would optimize health care costs associated with the treatment of CAD.
Computer-aided diagnosis in radiological imaging: current status and future challenges
NASA Astrophysics Data System (ADS)
Doi, Kunio
2009-10-01
Computer-aided diagnosis (CAD) has become one of the major research subjects in medical imaging and diagnostic radiology. Many different types of CAD schemes are being developed for detection and/or characterization of various lesions in medical imaging, including conventional projection radiography, CT, MRI, and ultrasound imaging. Commercial systems for detection of breast lesions on mammograms have been developed and have received FDA approval for clinical use. CAD may be defined as a diagnosis made by a physician who takes into account the computer output as a "second opinion". The purpose of CAD is to improve the quality and productivity of physicians in their interpretation of radiologic images. The quality of their work can be improved in terms of the accuracy and consistency of their radiologic diagnoses. In addition, the productivity of radiologists is expected to be improved by a reduction in the time required for their image readings. The computer output is derived from quantitative analysis of radiologic images by use of various methods and techniques in computer vision, artificial intelligence, and artificial neural networks (ANNs). The computer output may indicate a number of important parameters, for example, the locations of potential lesions such as lung cancer and breast cancer, the likelihood of malignancy of detected lesions, and the likelihood of various diseases based on differential diagnosis in a given image and clinical parameters. In this review article, the basic concept of CAD is first defined, and the current status of CAD research is then described. In addition, the potential of CAD in the future is discussed and predicted.
Nonin, Shinichi; Iwata, Shinichi; Sugioka, Kenichi; Fujita, Suwako; Norioka, Naoki; Ito, Asahiro; Nakagawa, Masashi; Yoshiyama, Minoru
2017-01-01
Although comprehensive risk factor modification is recommended, a uniform management strategy does not necessarily prevent secondary events in patients with coronary artery disease (CAD). Therefore, identification of high-risk patients who may benefit from more intensive interventions may improve prognosis. Carotid ultrasound can reliably identify systemic atherosclerosis, and carotid plaque and intima-media thickness (IMT) are known independent risk factors for CAD. However, it is unclear whether findings on carotid ultrasound can improve prediction of secondary CAD events. The study population comprised 146 consecutive patients with CAD (mean age, 66 ± 9 years; 126 with angina pectoris, 20 with acute myocardial infarction). IMT, plaque score, plaque area, plaque surface irregularity, and calcification length (calculated by summing the calcified lesions within each plaque accompanied by acoustic shadow) were measured at baseline. Patients were followed for 10 years to ascertain secondary CAD events defined as hard major adverse cardiovascular events (MACE; cardiac death and acute myocardial infarction) and as total MACE (hard MACE and angina pectoris with coronary revascularization). Multiple regression analysis demonstrated that calcification length (p < 0.05) and plaque surface irregularity (p < 0.01) remained independently associated with total MACE after adjustment for age, sex, diabetes mellitus, dyslipidemia, hypertension, chronic kidney disease, smoking, and multivessel CAD. These findings suggest that the combination of calcification length and plaque surface irregularity has additional value beyond traditional risk classification. Intensive intervention for these high-risk patients may avoid or delay progression of atherosclerosis towards secondary CAD events. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
López, Lenny; Cook, Nakela; Hicks, Leroi
2015-01-01
Primary care practices that concentrate linguistically and culturally appropriate services for Latinos may result in higher cardiology consultation rates and improved process measure performance for patients with coronary artery disease (CAD) and congestive heart failure (CHF). Multivariable Cox proportional-hazards regression was used to assess differences in referral at high proportion (HP) vs low proportion (LP) practices. Multivariable Poisson regression was used to assess the frequency of follow-up consultation. Among the 9,761 patients, 9,168 had CAD, 4,444 had CHF, and 3,851 had both conditions. Latinos comprised 11% of the CAD cohort and 11% of the CHF cohort. Multivariable analyses showed higher consultation rates for Latinos at HP practices for CAD and CHF. Blacks and Whites at HP practices had no significant differences in rates of consultation compared to those in LP practices. Latinos at HP practices had 25% more consultations for CAD and 23% more consultations for CHF than Latinos at LP practices. Latinos at HP clinics had higher overall mean quality performance on clinical measures for both CAD and CHF. Latinos at an LP clinic had the largest improvement in quality performance with consultation. Among Latinos with CAD or CHF receiving care within a single large academic care network, Latino patients at HP practices have higher rates of cardiologist consultation and performance on CVD process measures compared to Latino patients at LP practices. Elucidating the essential components of individual practice environments that provide higher quality of care for Latinos will allow for well designed systems to reduce health care disparities.
Zucuni, C P; Guilardi, L F; Fraga, S; May, L G; Pereira, G K R; Valandro, L F
2017-07-01
This study evaluated the effects of different pre-sintering fabrication processing techniques of Y-TZP ceramic (CAD/CAM Vs. in-lab), considering surface characteristics and mechanical performance outcomes. Pre-sintered discs of Y-TZP ceramic (IPS e.max ZirCAD, Ivoclar Vivadent) were produced using different pre-sintering fabrication processing techniques: Machined- milling with a CAD/CAM system; Polished- fabrication using a cutting device followed by polishing (600 and 1200 SiC papers); Xfine- fabrication using a cutting machine followed by grinding with extra-fine diamond bur (grit size 30 μm); Fine- fabrication using a cutting machine followed by grinding with fine diamond bur (grit size 46 μm); SiC- fabrication using a cutting machine followed by grinding with 220 SiC paper. Afterwards, the discs were sintered and submitted to roughness (n=35), surface topography (n=2), phase transformation (n=2), biaxial flexural strength (n=20), and biaxial flexural fatigue strength (fatigue limit) (n=15) analyses. No monoclinic-phase content was observed in all processing techniques. It can be observed that obtaining a surface with similar characteristics to CAD/CAM milling is essential for the observation of similar mechanical performance. On this sense, grinding with fine diamond bur before sintering (Fine group) was the best mimic protocol in comparison to the CAD/CAM milling. Copyright © 2017 Elsevier Ltd. All rights reserved.
Sagsoz, O; Yildiz, M; Hojjat Ghahramanzadeh, A S L; Alsaran, A
2018-03-01
The purpose of this study was to examine the fracture strength and surface microhardness of computer-aided design/computer-aided manufacturing (CAD/CAM) materials in vitro. Mesial-occlusal-distal inlays were made from five different CAD/CAM materials (feldspathic ceramic, CEREC blocs; leucite-reinforced ceramic, IPS Empress CAD; resin nano ceramic, 3M ESPE Lava Ultimate; hybrid ceramic, VITA Enamic; and lithium disilicate ceramic, IPS e.max CAD) using CEREC 4 CAD/CAM system. Samples were adhesively cemented to metal analogs with a resin cement (3M ESPE, U200). The fracture tests were carried out with a universal testing machine. Furthermore, five samples were prepared from each CAD/CAM material for micro-Vickers hardness test. Data were analyzed with statistics software SPSS 20 (IBM Corp., New York, USA). Fracture strength of lithium disilicate inlays (3949 N) was found to be higher than other ceramic inlays (P < 0.05). There was no difference between other inlays statistically (P > 0.05). The highest micro-Vickers hardness was measured in lithium disilicate samples, and the lowest was in resin nano ceramic samples. Fracture strength results demonstrate that inlays can withstand the forces in the mouth. Statistical results showed that fracture strength and micro-Vickers hardness of feldspathic ceramic, leucite-reinforced ceramic, and lithium disilicate ceramic materials had a positive correlation.
Alam, Md Shahid; Sugavaneswaran, M; Arumaikkannu, G; Mukherjee, Bipasha
2017-08-01
Ocular prosthesis is either a readymade stock shell or custom made prosthesis (CMP). Presently, there is no other technology available, which is either superior or even comparable to the conventional CMP. The present study was designed to fabricate ocular prosthesis using computer aided design (CAD) and rapid manufacturing (RM) technology and to compare it with custom made prosthesis (CMP). The ocular prosthesis prepared by CAD was compared with conventional CMP in terms of time taken for fabrication, weight, cosmesis, comfort, and motility. Two eyes of two patients were included. Computerized tomography scan of wax model of socket was converted into three dimensional format using Materialize Interactive Medical Image Control System (MIMICS)software and further refined. This was given as an input to rapid manufacturing machine (Polyjet 3-D printer). The final painting on prototype was done by an ocularist. The average effective time required for fabrication of CAD prosthesis was 2.5 hours; and weight 2.9 grams. The same for CMP were 10 hours; and 4.4 grams. CAD prosthesis was more comfortable for both the patients. The study demonstrates the first ever attempt of fabricating a complete ocular prosthesis using CAD and rapid manufacturing and comparing it with conventional CMP. This prosthesis takes lesser time for fabrication, and is more comfortable. Studies with larger sample size will be required to further validate this technique.
Mougiakakou, Stavroula G; Valavanis, Ioannis K; Nikita, Alexandra; Nikita, Konstantina S
2007-09-01
The aim of the present study is to define an optimally performing computer-aided diagnosis (CAD) architecture for the classification of liver tissue from non-enhanced computed tomography (CT) images into normal liver (C1), hepatic cyst (C2), hemangioma (C3), and hepatocellular carcinoma (C4). To this end, various CAD architectures, based on texture features and ensembles of classifiers (ECs), are comparatively assessed. Number of regions of interests (ROIs) corresponding to C1-C4 have been defined by experienced radiologists in non-enhanced liver CT images. For each ROI, five distinct sets of texture features were extracted using first order statistics, spatial gray level dependence matrix, gray level difference method, Laws' texture energy measures, and fractal dimension measurements. Two different ECs were constructed and compared. The first one consists of five multilayer perceptron neural networks (NNs), each using as input one of the computed texture feature sets or its reduced version after genetic algorithm-based feature selection. The second EC comprised five different primary classifiers, namely one multilayer perceptron NN, one probabilistic NN, and three k-nearest neighbor classifiers, each fed with the combination of the five texture feature sets or their reduced versions. The final decision of each EC was extracted by using appropriate voting schemes, while bootstrap re-sampling was utilized in order to estimate the generalization ability of the CAD architectures based on the available relatively small-sized data set. The best mean classification accuracy (84.96%) is achieved by the second EC using a fused feature set, and the weighted voting scheme. The fused feature set was obtained after appropriate feature selection applied to specific subsets of the original feature set. The comparative assessment of the various CAD architectures shows that combining three types of classifiers with a voting scheme, fed with identical feature sets obtained after appropriate feature selection and fusion, may result in an accurate system able to assist differential diagnosis of focal liver lesions from non-enhanced CT images.
Automated extraction of knowledge for model-based diagnostics
NASA Technical Reports Server (NTRS)
Gonzalez, Avelino J.; Myler, Harley R.; Towhidnejad, Massood; Mckenzie, Frederic D.; Kladke, Robin R.
1990-01-01
The concept of accessing computer aided design (CAD) design databases and extracting a process model automatically is investigated as a possible source for the generation of knowledge bases for model-based reasoning systems. The resulting system, referred to as automated knowledge generation (AKG), uses an object-oriented programming structure and constraint techniques as well as internal database of component descriptions to generate a frame-based structure that describes the model. The procedure has been designed to be general enough to be easily coupled to CAD systems that feature a database capable of providing label and connectivity data from the drawn system. The AKG system is capable of defining knowledge bases in formats required by various model-based reasoning tools.
Utilizing optical coherence tomography for CAD/CAM of indirect dental restorations
NASA Astrophysics Data System (ADS)
Chityala, Ravishankar; Vidal, Carola; Jones, Robert
Optical Coherence Tomography (OCT) has seen broad application in dentistry including early carious lesion detection and imaging defects in resin composite restorations. This study investigates expanding the clinical usefulness by investigating methods to use OCT for obtaining three-dimensional (3D) digital impressions, which can be integrated to CAD/CAM manufacturing of indirect restorations. 3D surface topography `before' and `after' a cavity preparation was acquired by an intraoral cross polarization swept source OCT (CP-OCT) system with a Micro-Electro-Mechanical System (MEMS) scanning mirror. Image registration and segmentation methods were used to digitally construct a replacement restoration that modeled the original surface morphology of a hydroxyapatite sample. After high resolution additive manufacturing (e.g. polymer 3D printing) of the replacement restoration, micro-CT imaging was performed to examine the marginal adaptation. This study establishes the protocol for further investigation of integrating OCT with CAD/CAM of indirect dental restorations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Linguraru, Marius George; Panjwani, Neil; Fletcher, Joel G.
2011-12-15
Purpose: To evaluate the performance of a computer-aided detection (CAD) system for detecting colonic polyps at noncathartic computed tomography colonography (CTC) in conjunction with an automated image-based colon cleansing algorithm. Methods: An automated colon cleansing algorithm was designed to detect and subtract tagged-stool, accounting for heterogeneity and poor tagging, to be used in conjunction with a colon CAD system. The method is locally adaptive and combines intensity, shape, and texture analysis with probabilistic optimization. CTC data from cathartic-free bowel preparation were acquired for testing and training the parameters. Patients underwent various colonic preparations with barium or Gastroview in divided dosesmore » over 48 h before scanning. No laxatives were administered and no dietary modifications were required. Cases were selected from a polyp-enriched cohort and included scans in which at least 90% of the solid stool was visually estimated to be tagged and each colonic segment was distended in either the prone or supine view. The CAD system was run comparatively with and without the stool subtraction algorithm. Results: The dataset comprised 38 CTC scans from prone and/or supine scans of 19 patients containing 44 polyps larger than 10 mm (22 unique polyps, if matched between prone and supine scans). The results are robust on fine details around folds, thin-stool linings on the colonic wall, near polyps and in large fluid/stool pools. The sensitivity of the CAD system is 70.5% per polyp at a rate of 5.75 false positives/scan without using the stool subtraction module. This detection improved significantly (p = 0.009) after automated colon cleansing on cathartic-free data to 86.4% true positive rate at 5.75 false positives/scan. Conclusions: An automated image-based colon cleansing algorithm designed to overcome the challenges of the noncathartic colon significantly improves the sensitivity of colon CAD by approximately 15%.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Elter, M.; Schulz-Wendtland, R.; Wittenberg, T.
2007-11-15
Mammography is the most effective method for breast cancer screening available today. However, the low positive predictive value of breast biopsy resulting from mammogram interpretation leads to approximately 70% unnecessary biopsies with benign outcomes. To reduce the high number of unnecessary breast biopsies, several computer-aided diagnosis (CAD) systems have been proposed in the last several years. These systems help physicians in their decision to perform a breast biopsy on a suspicious lesion seen in a mammogram or to perform a short term follow-up examination instead. We present two novel CAD approaches that both emphasize an intelligible decision process to predictmore » breast biopsy outcomes from BI-RADS findings. An intelligible reasoning process is an important requirement for the acceptance of CAD systems by physicians. The first approach induces a global model based on decison-tree learning. The second approach is based on case-based reasoning and applies an entropic similarity measure. We have evaluated the performance of both CAD approaches on two large publicly available mammography reference databases using receiver operating characteristic (ROC) analysis, bootstrap sampling, and the ANOVA statistical significance test. Both approaches outperform the diagnosis decisions of the physicians. Hence, both systems have the potential to reduce the number of unnecessary breast biopsies in clinical practice. A comparison of the performance of the proposed decision tree and CBR approaches with a state of the art approach based on artificial neural networks (ANN) shows that the CBR approach performs slightly better than the ANN approach, which in turn results in slightly better performance than the decision-tree approach. The differences are statistically significant (p value <0.001). On 2100 masses extracted from the DDSM database, the CRB approach for example resulted in an area under the ROC curve of A(z)=0.89{+-}0.01, the decision-tree approach in A(z)=0.87{+-}0.01, and the ANN approach in A(z)=0.88{+-}0.01.« less
A bipolar population counter using wave pipelining to achieve 2.5 x normal clock frequency
NASA Technical Reports Server (NTRS)
Wong, Derek C.; De Micheli, Giovanni; Flynn, Michael J.; Huston, Robert E.
1992-01-01
Wave pipelining is a technique for pipelining digital systems that can increase clock frequency in practical circuits without increasing the number of storage elements. In wave pipelining, multiple coherent waves of data are sent through a block of combinational logic by applying new inputs faster than the delay through the logic. The throughput of a 63-b CML population counter was increased from 97 to 250 MHz using wave pipelining. The internal circuit is flowthrough combinational logic. Novel CAD methods have balanced all input-to-output paths to about the same delay. This allows multiple data waves to propagate in sequence when the circuit is clocked faster than its propagation delay.
NASA Technical Reports Server (NTRS)
Starc, V.; Schlegel, T. T.; Arenare, B.; Greco, E. C.; DePalma, J. L.; Nunez, T.; Medina, R.; Jugo, D.; Rahman, M. A.; Delgado, R.
2007-01-01
We investigated the ability of beat-to-beat QT interval variability (QTV) and related parameters to differentiate healthy individuals from patients with obstructive coronary artery disease (CAD) and cardiomyopathy (CM). For this purpose we developed a PC-based ECG software program that in real time, acquires, analyzes and displays QTV in each of the eight independent channels that constitute the 12-lead conventional ECG. The system also analyzes and displays the QTV from QT interval signals that are derived from multiple channels and from singular value decomposition (SVD) to substantially reduce the effect of noise and other artifacts on the QTV results. It also provides other useful SVD-related parameters such as the normalized 3-dimensional volume of the T wave (nTV) = 100*(rho(sub 2)*rho(sub 3)rho(sub 1^2). Advanced high-fidelity 12-lead ECG tests (approx. 5-min supine) were first performed on a "training set" of 99 individuals: 33 with ischemic or dilated CM and low ejection fraction (EF less than 40%); 33 with catheterization-proven obstructive CAD but normal EF; and 33 age-/gender-matched healthy controls. All QTV parameters that were studied for their accuracy in detecting CM and CAD significantly differentiated both CM and CAD from controls (p less than 0.0001). Retrospective areas under the ROC curve (AUC) of SDNN-QTV, rmsSD-QTV, and QTV Index (QTVI) for CM vs. controls in the lead V5 were 0.85, 0.90, and 0.99, respectively, and those for CAD vs. controls in the lead II were 0.82, 0.82, and 0.89. Other advanced ECG parameters, such as HFQRS RAZ score, LF Lomb of RRV or QRS-T angle, differentiated both CM and CAD from controls less significantly, with the respective AUC values of 0.89, 0.88 and 0.98 for CM vs. controls, and 0.73, 0.71 and 0.80 for CAD vs. controls. QTV parameters (especially QTVI, which is QTV as indexed to RRV) were, diagnostically speaking, amongst the best performing of the advanced ECG techniques studied thus far.
Bhattacharyya, Dipto; Hazra, Saptarshi; Banerjee, Anindyajit; Datta, Riddhi; Kumar, Deepak; Chakrabarti, Saikat; Chattopadhyay, Sharmila
2016-09-01
Podophyllotoxin (ptox) is a therapeutically important lignan derived from Podophyllum hexandrum and is used as a precursor for the synthesis of anticancer drugs etoposide, teniposide and etopophose. In spite of its enormous economic significance, genomic information on this endangered medicinal herb is scarce. We have performed de novo transcriptome analysis of methyl jasmonate (MeJA)-treated P. hexandrum cell cultures exhibiting enhanced ptox accumulation. The results revealed the maximum up-regulation of several isoforms of cinnamyl alcohol dehydrogenase (CAD). CAD catalyzes the synthesis of coniferyl alcohol and sinapyl alcohol from coniferaldehyde (CAld) and sinapaldehyde respectively. Coniferyl alcohol can produce both lignin and lignan while sinapyl alcohol produces only lignin. To isolate the CAD isoforms favoring ptox, we deduced full length cDNA sequences of four CAD isoforms: PhCAD1, PhCAD2, PhCAD3 and PhCAD4 from the contigs of the transcriptome data. In vitro enzyme assays indicated a higher affinity for CAld over sinapaldehyde for each isoform. In silico molecular docking analyses also suggested that PhCAD3 has a higher binding preference with CAld over sinapaldehyde, followed by PhCAD4, PhCAD2, and PhCAD1, respectively. The transgenic cell cultures overexpressing these isoforms independently revealed that PhCAD3 favored the maximum accumulation of ptox as compared to lignin followed by PhCAD4 and PhCAD2, whereas, PhCAD1 favored both equally. Together, our study reveals transcriptome-wide identification and characterization of ptox specific CAD isoforms from P. hexandrum. It provides a useful resource for future research not only on the ptox biosynthetic pathway but on overall P. hexandrum, an endangered medicinal herb with immense therapeutic importance.
A completely automated CAD system for mass detection in a large mammographic database.
Bellotti, R; De Carlo, F; Tangaro, S; Gargano, G; Maggipinto, G; Castellano, M; Massafra, R; Cascio, D; Fauci, F; Magro, R; Raso, G; Lauria, A; Forni, G; Bagnasco, S; Cerello, P; Zanon, E; Cheran, S C; Lopez Torres, E; Bottigli, U; Masala, G L; Oliva, P; Retico, A; Fantacci, M E; Cataldo, R; De Mitri, I; De Nunzio, G
2006-08-01
Mass localization plays a crucial role in computer-aided detection (CAD) systems for the classification of suspicious regions in mammograms. In this article we present a completely automated classification system for the detection of masses in digitized mammographic images. The tool system we discuss consists in three processing levels: (a) Image segmentation for the localization of regions of interest (ROIs). This step relies on an iterative dynamical threshold algorithm able to select iso-intensity closed contours around gray level maxima of the mammogram. (b) ROI characterization by means of textural features computed from the gray tone spatial dependence matrix (GTSDM), containing second-order spatial statistics information on the pixel gray level intensity. As the images under study were recorded in different centers and with different machine settings, eight GTSDM features were selected so as to be invariant under monotonic transformation. In this way, the images do not need to be normalized, as the adopted features depend on the texture only, rather than on the gray tone levels, too. (c) ROI classification by means of a neural network, with supervision provided by the radiologist's diagnosis. The CAD system was evaluated on a large database of 3369 mammographic images [2307 negative, 1062 pathological (or positive), containing at least one confirmed mass, as diagnosed by an expert radiologist]. To assess the performance of the system, receiver operating characteristic (ROC) and free-response ROC analysis were employed. The area under the ROC curve was found to be Az = 0.783 +/- 0.008 for the ROI-based classification. When evaluating the accuracy of the CAD against the radiologist-drawn boundaries, 4.23 false positives per image are found at 80% of mass sensitivity.
Combining Feature Extraction Methods to Assist the Diagnosis of Alzheimer's Disease.
Segovia, F; Górriz, J M; Ramírez, J; Phillips, C
2016-01-01
Neuroimaging data as (18)F-FDG PET is widely used to assist the diagnosis of Alzheimer's disease (AD). Looking for regions with hypoperfusion/ hypometabolism, clinicians may predict or corroborate the diagnosis of the patients. Modern computer aided diagnosis (CAD) systems based on the statistical analysis of whole neuroimages are more accurate than classical systems based on quantifying the uptake of some predefined regions of interests (ROIs). In addition, these new systems allow determining new ROIs and take advantage of the huge amount of information comprised in neuroimaging data. A major branch of modern CAD systems for AD is based on multivariate techniques, which analyse a neuroimage as a whole, considering not only the voxel intensities but also the relations among them. In order to deal with the vast dimensionality of the data, a number of feature extraction methods have been successfully applied. In this work, we propose a CAD system based on the combination of several feature extraction techniques. First, some commonly used feature extraction methods based on the analysis of the variance (as principal component analysis), on the factorization of the data (as non-negative matrix factorization) and on classical magnitudes (as Haralick features) were simultaneously applied to the original data. These feature sets were then combined by means of two different combination approaches: i) using a single classifier and a multiple kernel learning approach and ii) using an ensemble of classifier and selecting the final decision by majority voting. The proposed approach was evaluated using a labelled neuroimaging database along with a cross validation scheme. As conclusion, the proposed CAD system performed better than approaches using only one feature extraction technique. We also provide a fair comparison (using the same database) of the selected feature extraction methods.
Zimmermann, M; Valcanaia, A; Neiva, G; Mehl, A; Fasbinder, D
2018-04-09
CAM fabrication is an important step within the CAD/CAM process. The internal fit of restorations is influenced by the accuracy of the subtractive CAM procedure. Little is known about how CAM strategies might influence the fit of CAD/CAM fabricated restorations. The aim of this study was to three-dimensionally evaluate the fit of CAD/CAM fabricated zirconia-reinforced lithium silicate ceramic partial crowns fabricated with three different CAM strategies. The null hypothesis was that different CAM strategies did not influence the fitting accuracy of CAD/CAM fabricated zirconia-reinforced lithium silicate ceramic partial crowns. Preparation for a partial crown was performed on a maxillary right first molar on a typodont. A chairside CAD/CAM system with the intraoral scanning device CEREC Omnicam (Dentsply Sirona, York, PA, USA) and the 3+1 axis milling unit CEREC MCXL was used. There were three groups with different CAM strategies: step bur 12 (12), step bur 12S (12S), and two step-mode (12TWO). The zirconia-reinforced lithium silicate ceramic Celtra Duo (Dentsply Sirona) was used as the CAD/CAM material. A new 3D method for evaluating the fit was applied, consisting of the quadrant scan with the intraoral scanning device CEREC Omnicam. The scan of the PVS material adherent to the preparation and the preparation scan were matched, and the difference analysis was performed with special software OraCheck (Cyfex AG, Zurich, Switzerland). Three areas were selected for analysis: margin (MA), axial (AX), and occlusal (OC). Statistical analysis was performed using 80% percentile, one-way ANOVA, and the post hoc Scheffé test with α=0.05. Statistically significant differences were found both within and between the test groups. The aspect axial fit results varied from 90.5 ± 20.1 μm for the two-step milling mode (12TWO_AX) to 122.8 ± 12.2 μm for the milling with step bur 12S (12S_AX). The worst result in all groups was found for the aspect occlusal fit with the highest value for group 12S of 222.8 ± 35.6 μm. Group two-step milling mode (12TWO) performed statistically significantly better from groups 12 and 12S for the occlusal fit ( p<0.05). Deviation patterns were visually analyzed with a color-coded scheme for each restoration. CAM strategy influenced the internal adaptation of zirconia-reinforced lithium silicate partial crowns fabricated with a chairside CAD/CAM system. Sensible selection of specific areas of internal adaptation and fit is an important factor for evaluating the CAM accuracy of CAD/CAM systems.
Giger, Maryellen L.; Chan, Heang-Ping; Boone, John
2008-01-01
The roles of physicists in medical imaging have expanded over the years, from the study of imaging systems (sources and detectors) and dose to the assessment of image quality and perception, the development of image processing techniques, and the development of image analysis methods to assist in detection and diagnosis. The latter is a natural extension of medical physicists’ goals in developing imaging techniques to help physicians acquire diagnostic information and improve clinical decisions. Studies indicate that radiologists do not detect all abnormalities on images that are visible on retrospective review, and they do not always correctly characterize abnormalities that are found. Since the 1950s, the potential use of computers had been considered for analysis of radiographic abnormalities. In the mid-1980s, however, medical physicists and radiologists began major research efforts for computer-aided detection or computer-aided diagnosis (CAD), that is, using the computer output as an aid to radiologists—as opposed to a completely automatic computer interpretation—focusing initially on methods for the detection of lesions on chest radiographs and mammograms. Since then, extensive investigations of computerized image analysis for detection or diagnosis of abnormalities in a variety of 2D and 3D medical images have been conducted. The growth of CAD over the past 20 years has been tremendous—from the early days of time-consuming film digitization and CPU-intensive computations on a limited number of cases to its current status in which developed CAD approaches are evaluated rigorously on large clinically relevant databases. CAD research by medical physicists includes many aspects—collecting relevant normal and pathological cases; developing computer algorithms appropriate for the medical interpretation task including those for segmentation, feature extraction, and classifier design; developing methodology for assessing CAD performance; validating the algorithms using appropriate cases to measure performance and robustness; conducting observer studies with which to evaluate radiologists in the diagnostic task without and with the use of the computer aid; and ultimately assessing performance with a clinical trial. Medical physicists also have an important role in quantitative imaging, by validating the quantitative integrity of scanners and developing imaging techniques, and image analysis tools that extract quantitative data in a more accurate and automated fashion. As imaging systems become more complex and the need for better quantitative information from images grows, the future includes the combined research efforts from physicists working in CAD with those working on quantitative imaging systems to readily yield information on morphology, function, molecular structure, and more—from animal imaging research to clinical patient care. A historical review of CAD and a discussion of challenges for the future are presented here, along with the extension to quantitative image analysis. PMID:19175137
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giger, Maryellen L.; Chan, Heang-Ping; Boone, John
2008-12-15
The roles of physicists in medical imaging have expanded over the years, from the study of imaging systems (sources and detectors) and dose to the assessment of image quality and perception, the development of image processing techniques, and the development of image analysis methods to assist in detection and diagnosis. The latter is a natural extension of medical physicists' goals in developing imaging techniques to help physicians acquire diagnostic information and improve clinical decisions. Studies indicate that radiologists do not detect all abnormalities on images that are visible on retrospective review, and they do not always correctly characterize abnormalities thatmore » are found. Since the 1950s, the potential use of computers had been considered for analysis of radiographic abnormalities. In the mid-1980s, however, medical physicists and radiologists began major research efforts for computer-aided detection or computer-aided diagnosis (CAD), that is, using the computer output as an aid to radiologists--as opposed to a completely automatic computer interpretation--focusing initially on methods for the detection of lesions on chest radiographs and mammograms. Since then, extensive investigations of computerized image analysis for detection or diagnosis of abnormalities in a variety of 2D and 3D medical images have been conducted. The growth of CAD over the past 20 years has been tremendous--from the early days of time-consuming film digitization and CPU-intensive computations on a limited number of cases to its current status in which developed CAD approaches are evaluated rigorously on large clinically relevant databases. CAD research by medical physicists includes many aspects--collecting relevant normal and pathological cases; developing computer algorithms appropriate for the medical interpretation task including those for segmentation, feature extraction, and classifier design; developing methodology for assessing CAD performance; validating the algorithms using appropriate cases to measure performance and robustness; conducting observer studies with which to evaluate radiologists in the diagnostic task without and with the use of the computer aid; and ultimately assessing performance with a clinical trial. Medical physicists also have an important role in quantitative imaging, by validating the quantitative integrity of scanners and developing imaging techniques, and image analysis tools that extract quantitative data in a more accurate and automated fashion. As imaging systems become more complex and the need for better quantitative information from images grows, the future includes the combined research efforts from physicists working in CAD with those working on quantitative imaging systems to readily yield information on morphology, function, molecular structure, and more--from animal imaging research to clinical patient care. A historical review of CAD and a discussion of challenges for the future are presented here, along with the extension to quantitative image analysis.« less
Flume Computer-Aided Design (CAD): Integrated CAD for Microflume Components and Systems
2002-04-01
31 3.3: Matching the Mix Ratio (Part B...sizes) will be optimized based on the required flow rates and mixing ratios of the different species. The influence of etch depth is investigated on a...Inhibition Study In this network, the target protein is mixed with protease (i.e. enzyme that cleaves the target protein) and the protease inhibitor (the
ERIC Educational Resources Information Center
Smith, Richard J.; Sauer, Mardelle A.
This guide is intended to assist teachers in using computer-aided design (CAD) workstations and artificial intelligence software to teach basic drafting skills. The guide outlines a 7-unit shell program that may also be used as a generic authoring system capable of supporting computer-based training (CBT) in other subject areas. The first section…
Jun, Se-Young; Walker, Alexander M; Kim, Hoon; Ralph, John; Vermerris, Wilfred; Sattler, Scott E; Kang, ChulHee
2017-08-01
Cinnamyl alcohol dehydrogenase (CAD) catalyzes the final step in monolignol biosynthesis, reducing sinapaldehyde, coniferaldehyde, and p -coumaraldehyde to their corresponding alcohols in an NADPH-dependent manner. Because of its terminal location in monolignol biosynthesis, the variation in substrate specificity and activity of CAD can result in significant changes in overall composition and amount of lignin. Our in-depth characterization of two major CAD isoforms, SbCAD2 (Brown midrib 6 [bmr6]) and SbCAD4, in lignifying tissues of sorghum ( Sorghum bicolor ), a strategic plant for generating renewable chemicals and fuels, indicates their similarity in both structure and activity to Arabidopsis ( Arabidopsis thaliana ) CAD5 and Populus tremuloides sinapyl alcohol dehydrogenase, respectively. This first crystal structure of a monocot CAD combined with enzyme kinetic data and a catalytic model supported by site-directed mutagenesis allows full comparison with dicot CADs and elucidates the potential signature sequence for their substrate specificity and activity. The L119W/G301F-SbCAD4 double mutant displayed its substrate preference in the order coniferaldehyde > p -coumaraldehyde > sinapaldehyde, with higher catalytic efficiency than that of both wild-type SbCAD4 and SbCAD2. As SbCAD4 is the only major CAD isoform in bmr6 mutants, replacing SbCAD4 with L119W/G301F-SbCAD4 in bmr6 plants could produce a phenotype that is more amenable to biomass processing. © 2017 American Society of Plant Biologists. All Rights Reserved.
Song, Yang; Zhao, Yi-jiao; Sun, Yu-chun; Lü, Pei-jun; Wang, Yong
2013-09-01
To evaluate the design and manufacture accuracy of a domestic computer aided design (CAD) and computer aided manufacture (CAM) system, and to compare it with similar foreign products. Thirty models of posterior-teeth-single-crown preparations were collected, and STL data of these preparations was collected by Denmark 3Shape scanner. Three copings were made for each preparation, the one designed and manufactured using commercial CAD/CAM system (3Shape CAD software and Wieland T1 CAM equipment) was assigned into control group T0, the one designed and manufactured using domestic CAD software (developed by Peking University School and Hospital of Stomatology and Nanjing University of Aeronautics and Astronautics) and Wieland T1 CAM equipment was assigned into experimental group TCAD for design accuracy evaluation, and the one designed and manufactured using 3Shape CAD software and domestic CAM equipment (developed by Peking University School and Hospital of Stomatology, Tsinghua University and ShanDong XinHua Incorporated Company of medical apparatus and instruments) was assigned into experimental group TCAM for manufacture accuracy evaluation. Finally, the marginal fitness were compared and evaluated by using 3D & Profile measurement microscope laser. The marginal fitness of TCAD was 27.98 (19.10, 46.57) µm in buccal, 32.67 (20.65, 50.82) µm in lingual, 27.38 (22.53, 52.61) µm in mesial, 29.50 (22.68, 53.65) µm in distal; of TCAM was 21.69 (15.87, 30.21) µm in buccal, 18.51 (13.50, 22.51) µm in lingual, 19.15 (15.42, 26.89) µm in mesial, 22.77 (18.58, 32.15) µm in distal; and there were no statistical differences compared with T0 [20.16 (17.16, 48.00) µm in buccal, 21.51 (17.05, 28.31) µm in lingual, 23.54 (17.89, 30.04) µm in mesial and 23.94 (17.93, 28.19) µm in distal] except lingual data of TCAD. The design and machining precision of this domestic CAD/CAM system is at the same level of those comparable foreign products.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bueno, G.; Ruiz, M.; Sanchez, S
Breast cancer continues to be an important health problem between women population. Early detection is the only way to improve breast cancer prognosis and significantly reduce women mortality. It is by using CAD systems that radiologist can improve their ability to detect, and classify lesions in mammograms. In this study the usefulness of using B-spline based on a gradient scheme and compared to wavelet and adaptative filtering has been investigated for calcification lesion detection and as part of CAD systems. The technique has been applied to different density tissues. A qualitative validation shows the success of the method.
Neural networks: Application to medical imaging
NASA Technical Reports Server (NTRS)
Clarke, Laurence P.
1994-01-01
The research mission is the development of computer assisted diagnostic (CAD) methods for improved diagnosis of medical images including digital x-ray sensors and tomographic imaging modalities. The CAD algorithms include advanced methods for adaptive nonlinear filters for image noise suppression, hybrid wavelet methods for feature segmentation and enhancement, and high convergence neural networks for feature detection and VLSI implementation of neural networks for real time analysis. Other missions include (1) implementation of CAD methods on hospital based picture archiving computer systems (PACS) and information networks for central and remote diagnosis and (2) collaboration with defense and medical industry, NASA, and federal laboratories in the area of dual use technology conversion from defense or aerospace to medicine.
CAD/CAM for development and fabrication of cosecant reflector antennas
NASA Astrophysics Data System (ADS)
Petri, U.
The application of CAD/CAM techniques to lower the cost of redesigning and manufacturing specialized cosecant reflector antennas for use in the mm-wave range is described and demonstrated. Consideration is given to the theoretical computation of reflector surfaces; the representation of a reflector surface in a CAD system; the numerically controlled milling of an Al, wood, or plastic model antenna; and the construction of the antenna (by spraying the 300-micron Sn-alloy conducting layer onto the coated model surface and then applying a 1-mm-thick epoxy-matrix GFRP layer, a 20-30-mm layer of flexible polyurethane foam, and a final GFRP layer). Diagrams and photographs are provided.
Freeform surface measurement and characterisation using a toolmakers microscope
NASA Astrophysics Data System (ADS)
Seung-yin Wong, Francis; Chauh, Kong-Bieng; Venuvinod, Patri K.
2014-03-01
Current freeform surface (FFS) characterization systems mainly cover aspects related to computer-aided design/manufacture (CAD/CAM). This paper describes a new approach that extends into computer-aided inspection (CAI).The following novel features are addressed: blacksquare Feature recognition and extraction from surface data blacksquare Characterisation of properties of the surface's M and N vectors at individual vertex blacksquare Development of a measuring plan using a toolmakers microscope for the inspection of the FFS blacksquare Inspection of the actual FFS produced by CNC milling blacksquare Verification of the measurement results and comparison with the CAD design data Tests have shown that the deviations between the CAI and CAD data were within the estimated uncertainty limits.