Laser Transformation Hardening of Firing Zone Cutout Cams.
1981-06-01
bath nitriding to case harden firing zone cutout cams for the Mk 10 Guided Missile Launcher System (GMLS). These cams, machined of 4340 steel ...salt bath nitriding to case harden firing zone cutout cams for the Mk 10 Guided Missile Launcher System (GMLS). These cams, machined of 4340 steel ...Patterns ........ ................ 8 9 Laser Beam Step Pattern ...... .................. .. 10 10 Hardness Profile, 4340 Steel
NASA Astrophysics Data System (ADS)
Webster, Jordan
2017-01-01
Dense track environments in pp collisions at the Large Hadron Collider (LHC) motivate the use of triggers with dedicated hardware for fast track reconstruction. The ATLAS Collaboration is in the process of implementing a Fast Tracker (FTK) trigger upgrade, in which Content Addressable Memories (CAMs) will be used to rapidly match hit patterns with large banks of simulated tracks. The FTK CAMs are produced primarily at the University of Pisa. However, commercial CAM technology is rapidly developing due to applications in computer networking devices. This poster presents new studies comparing FTK CAMs to cutting-edge ternary CAMs developed by Cavium. The comparison is intended to guide the design of future track-based trigger systems for the next Phase at the LHC.
Management of CAD/CAM information: Key to improved manufacturing productivity
NASA Technical Reports Server (NTRS)
Fulton, R. E.; Brainin, J.
1984-01-01
A key element to improved industry productivity is effective management of CAD/CAM information. To stimulate advancements in this area, a joint NASA/Navy/Industry project designated Integrated Programs for Aerospace-Vehicle Design (IPAD) is underway with the goal of raising aerospace industry productivity through advancement of technology to integrate and manage information involved in the design and manufacturing process. The project complements traditional NASA/DOD research to develop aerospace design technology and the Air Force's Integrated Computer-Aided Manufacturing (ICAM) program to advance CAM technology. IPAD research is guided by an Industry Technical Advisory Board (ITAB) composed of over 100 repesentatives from aerospace and computer companies. The IPAD accomplishments to date in development of requirements and prototype software for various levels of company-wide CAD/CAM data management are summarized and plans for development of technology for management of distributed CAD/CAM data and information required to control future knowledge-based CAD/CAM systems are discussed.
Split-mouth comparison of the accuracy of computer-generated and conventional surgical guides.
Farley, Nathaniel E; Kennedy, Kelly; McGlumphy, Edwin A; Clelland, Nancy L
2013-01-01
Recent clinical studies have shown that implant placement is highly predictable with computer-generated surgical guides; however, the reliability of these guides has not been compared to that of conventional guides clinically. This study aimed to compare the accuracy of reproducing planned implant positions with computer-generated and conventional surgical guides using a split-mouth design. Ten patients received two implants each in symmetric locations. All implants were planned virtually using a software program and information from cone beam computed tomographic scans taken with scan appliances in place. Patients were randomly selected for computer-aided design/computer-assisted manufacture (CAD/CAM)-guided implant placement on their right or left side. Conventional guides were used on the contralateral side. Patients underwent operative cone beam computed tomography postoperatively. Planned and actual implant positions were compared using three-dimensional analyses capable of measuring volume overlap as well as differences in angles and coronal and apical positions. Results were compared using a mixed-model repeated-measures analysis of variance and were further analyzed using a Bartlett test for unequal variance (α = .05). Implants placed with CAD/CAM guides were closer to the planned positions in all eight categories examined. However, statistically significant differences were shown only for coronal horizontal distances. It was also shown that CAD/CAM guides had less variability than conventional guides, which was statistically significant for apical distance. Implants placed using CAD/CAM surgical guides provided greater accuracy in a lateral direction than conventional guides. In addition, CAD/CAM guides were more consistent in their deviation from the planned locations than conventional guides.
Leong, Frederick T; Lee, Szu-Hui
2006-01-01
As an extension of F. T. L. Leong's (1996) integrative model, this article presents the cultural accommodation model (CAM), an enhanced theoretical guide to effective cross-cultural clinical practice and research. Whereas F. T. L. Leong's model identifies the importance of integrating the universal, group, and individual dimensions, the CAM takes the next step by providing a theoretical guide to effective psychotherapy with culturally different clients by means of a cultural accommodation process. This model argues for the importance of selecting and applying culture-specific constructs when working with culturally diverse groups. The first step of the CAM is to identify cultural disparities that are often ignored and then accommodate them by using current culturally specific concepts. In this article, several different cultural "gaps" or culture-specific constructs of relevance to Asian Americans with strong scientific foundations are selected and discussed as they pertain to providing effective psychotherapy to this ethnic minority group. Finally, a case study is incorporated to illustrate application of the CAM. (PsycINFO Database Record (c) 2010 APA, all rights reserved).
Park, Su-Jung; Leesungbok, Richard; Cui, Taixing; Lee, Suk Won; Ahn, Su-Jin
This in vitro study evaluated the reliability of a surgical guide with regard to different levels of operator surgical experience and implant site. A stereolithographic surgical guide for epoxy resin mandibles with three edentulous molar sites was produced using a computer-aided design/computer-assisted manufacture (CAD/CAM) system. Two surgeons with and two surgeons without implant surgery experience placed implants in a model either using or not using the CAD/CAM surgical guide. Four groups were created: inexperienced surgeon without the guide (group 1); experienced surgeon without the guide (group 2); inexperienced surgeon with the guide (group 3); and experienced surgeon with the guide (group 4). Planned implants and placed implants were superimposed using digital software, and deviation parameters were calculated. There were no significant differences in any of the deviation parameters between the groups when using the surgical guide. With respect to the implant sites, there were no significant differences among the groups in any parameter. Use of the CAD/CAM surgical guide reduced discrepancies among operators performing implant surgery regardless of their level of experience. Whether or not the guide was used, differences in the anterior-posterior implant site in the molar area did not affect the accuracy of implant placement.
Attias, Samuel; Keinan Boker, Lital; Arnon, Zahi; Ben-Arye, Eran; Bar'am, Ayala; Sroka, Gideon; Matter, Ibrahim; Somri, Mostafa; Schiff, Elad
2016-03-01
Preoperative anxiety is commonly reported by people undergoing surgery. A significant number of studies have found a correlation between preoperative anxiety and post-operative morbidity. Various methods of complementary and alternative medicine (CAM) were found to be effective in alleviating preoperative anxiety. This study examined the relative effectiveness of various individual and generic CAM methods combined with standard treatment (ST) in relieving preoperative anxiety, in comparison with ST alone. Randomized controlled trial. Holding room area Three hundred sixty patients. Patients were randomly divided into 6 equal-sized groups. Group 1 received the standard treatment (ST) for anxiety alleviation with anxiolytics. The five other groups received the following, together with ST (anxiolytics): Compact Disk Recording of Guided Imagery (CDRGI); acupuncture; individual guided imagery; reflexology; and individual guided imagery combined with reflexology, based on medical staff availability. Assessment of anxiety was taken upon entering the holding room area (surgery preparation room) ('pre-treatment assessment'), and following the treatment, shortly before transfer to the operating room ('post-treatment assessment'), based on the Visual Analogue Scale (VAS) questionnaire. Data processing included comparison of VAS averages in the 'pre' and 'post' stages among the various groups. Preoperatively, CAM treatments were associated with significant reduction of anxiety level (5.54-2.32, p<0.0001). In contrast, no significant change was noted in the standard treatment group (4.92-5.44, p=0.15). Individualized CAM treatments did not differ significantly in outcomes. However, CDRGI was less effective than individualized CAM (P<0.001), but better than ST (p=0.005). Individual CAM treatments integrated within ST reduce preoperative anxiety significantly, compared to standard treatment alone, and are more effective than generic CDRGI. In light of the scope of preoperative anxiety and its implications for public health, integration of CAM therapies with ST should be considered for reducing preoperative anxiety. Copyright © 2016 Elsevier Inc. All rights reserved.
What should students learn about complementary and alternative medicine?
Gaster, Barak; Unterborn, John N; Scott, Richard B; Schneeweiss, Ronald
2007-10-01
With thousands of complementary and alternative medicine (CAM) treatments currently being used in the United States today, it is challenging to design a concise body of CAM content which will fit into already overly full curricula for health care students. The purpose of this article is to outline key principles which 15 National Center for Complementary and Alternative Medicine-funded education programs found useful when developing CAM course-work and selecting CAM content. Three key guiding principles are discussed: teach foundational CAM competencies to give students a framework for learning about CAM; choose specific content on the basis of evidence, demographics and condition (what conditions are most appropriate for CAM therapies?); and finally, provide students with skills for future learning, including where to find reliable information about CAM and how to search the scientific literature and assess the results of CAM research. Most of the programs developed evidence-based guides to help students find reliable CAM resources. The cumulative experiences of the 15 programs have been compiled, and an annotated table outlining the most highly recommended resources about CAM is presented.
Management of CAD/CAM information: Key to improved manufacturing productivity
NASA Technical Reports Server (NTRS)
Fulton, R. E.; Brainin, J.
1984-01-01
A key element to improved industry productivity is effective management of CAD/CAM information. To stimulate advancements in this area, a joint NASA/Navy/industry project designated Intergrated Programs for Aerospace-Vehicle Design (IPAD) is underway with the goal of raising aerospace industry productivity through advancement of technology to integrate and manage information involved in the design and manufacturing process. The project complements traditional NASA/DOD research to develop aerospace design technology and the Air Force's Integrated Computer-Aided Manufacturing (ICAM) program to advance CAM technology. IPAD research is guided by an Industry Technical Advisory Board (ITAB) composed of over 100 representatives from aerospace and computer companies.
Scherer, Michael D; Kattadiyil, Mathew T; Parciak, Ewa; Puri, Shweta
2014-01-01
Three-dimensional radiographic imaging for dental implant treatment planning is gaining widespread interest and popularity. However, application of the data from 30 imaging can be a complex and daunting process initially. The purpose of this article is to describe features of three software packages and the respective computerized guided surgical templates (GST) fabricated from them. A step-by-step method of interpreting and ordering a GST to simplify the process of the surgical planning and implant placement is discussed.
Numajiri, Toshiaki; Morita, Daiki; Nakamura, Hiroko; Tsujiko, Shoko; Yamochi, Ryo; Sowa, Yoshihiro; Toyoda, Kenichiro; Tsujikawa, Takahiro; Arai, Akihito; Yasuda, Makoto; Hirano, Shigeru
2018-06-01
Computer-assisted design (CAD) and computer-aided manufacturing (CAM) techniques are in widespread use for maxillofacial reconstruction. However, CAD/CAM surgical guides are commercially available only in limited areas. To use this technology in areas where these commercial guides are not available, the authors developed a CAD/CAM technique in which all processes are performed by the surgeon (in-house approach). The authors describe their experience and the characteristics of their in-house CAD/CAM reconstruction of the maxilla. This was a retrospective study of maxillary reconstruction with a free osteocutaneous flap. Free CAD software was used for virtual surgery and to design the cutting guides (maxilla and fibula), which were printed by a 3-dimensional printer. After the model surgery and pre-bending of the titanium plates, the actual reconstructions were performed. The authors compared the clinical information, preoperative plan, and postoperative reconstruction data. The reconstruction was judged as accurate if more than 80% of the reconstructed points were within a deviation of 2 mm. Although on-site adjustment was necessary in particular cases, all 4 reconstructions were judged as accurate. In total, 3 days were needed before the surgery for planning, printing, and pre-bending of plates. The average ischemic time was 134 minutes (flap suturing and bone fixation, 70 minutes; vascular anastomoses, 64 minutes). The mean deviation after reconstruction was 0.44 mm (standard deviation, 0.97). The deviations were 67.8% for 1 mm, 93.8% for 2 mm, and 98.6% for 3 mm. The disadvantages of the regular use of CAD/CAM reconstruction are the intraoperative changes in defect size and local tissue scarring. Good accuracy was obtained for CAD/CAM-guided reconstructions based on an in-house approach. The theoretical advantage of computer simulation contributes to the accuracy. An in-house approach could be an option for maxillary reconstruction. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Weeks, Laura; Balneaves, Lynda G; Paterson, Charlotte; Verhoef, Marja
2014-01-01
Patients with cancer consistently report conflict and anxiety when making decisions about complementary and alternative medicine (CAM) treatment. To design evidence-informed decision-support strategies, a better understanding is needed of how the decision-making process unfolds for these patients during their experience with cancer. We undertook this study to review the research literature regarding CAM-related decision-making by patients with cancer within the context of treatment, survivorship, and palliation. We also aimed to summarize emergent concepts within a preliminary conceptual framework. We conducted an integrative literature review, searching 12 electronic databases for articles published in English that described studies of the process, context, or outcomes of CAM-related decision-making. We summarized descriptive data using frequencies and used a descriptive constant comparative method to analyze statements about original qualitative results, with the goal of identifying distinct concepts pertaining to CAM-related decision-making by patients with cancer and the relationships among these concepts. Of 425 articles initially identified, 35 met our inclusion criteria. Seven unique concepts related to CAM and cancer decision-making emerged: decision-making phases, information-seeking and evaluation, decision-making roles, beliefs, contextual factors, decision-making outcomes, and the relationship between CAM and conventional medical decision-making. CAM decision-making begins with the diagnosis of cancer and encompasses 3 distinct phases (early, mid, and late), each marked by unique aims for CAM treatment and distinct patterns of information-seeking and evaluation. Phase transitions correspond to changes in health status or other milestones within the cancer trajectory. An emergent conceptual framework illustrating relationships among the 7 central concepts is presented. CAM-related decision-making by patients with cancer occurs as a nonlinear, complex, dynamic process. The conceptual framework presented here identifies influential factors within that process, as well as patients' unique needs during different phases. The framework can guide the development and evaluation of theory-based decision-support programs that are responsive to patients' beliefs and preferences.
Weeks, Laura; Balneaves, Lynda G; Paterson, Charlotte
2014-01-01
Background: Patients with cancer consistently report conflict and anxiety when making decisions about complementary and alternative medicine (CAM) treatment. To design evidence-informed decision-support strategies, a better understanding is needed of how the decision-making process unfolds for these patients during their experience with cancer. We undertook this study to review the research literature regarding CAM-related decisionmaking by patients with cancer within the context of treatment, survivorship, and palliation. We also aimed to summarize emergent concepts within a preliminary conceptual framework. Methods: We conducted an integrative literature review, searching 12 electronic databases for articles published in English that described studies of the process, context, or outcomes of CAM-related decision-making. We summarized descriptive data using frequencies and used a descriptive constant comparative method to analyze statements about original qualitative results, with the goal of identifying distinct concepts pertaining to CAM-related decision-making by patients with cancer and the relationships among these concepts. Results: Of 425 articles initially identified, 35 met our inclusion criteria. Seven unique concepts related to CAM and cancer decision-making emerged: decision-making phases, information-seeking and evaluation, decision-making roles, beliefs, contextual factors, decision-making outcomes, and the relationship between CAM and conventional medical decision-making. CAM decision-making begins with the diagnosis of cancer and encompasses 3 distinct phases (early, mid, and late), each marked by unique aims for CAM treatment and distinct patterns of informationseeking and evaluation. Phase transitions correspond to changes in health status or other milestones within the cancer trajectory. An emergent conceptual framework illustrating relationships among the 7 central concepts is presented. Interpretation: CAM-related decision-making by patients with cancer occurs as a nonlinear, complex, dynamic process. The conceptual framework presented here identifies influential factors within that process, as well as patients' unique needs during different phases. The framework can guide the development and evaluation of theorybased decision-support programs that are responsive to patients' beliefs and preferences. PMID:25009685
[The Confusion Assessment Method: Transcultural adaptation of a French version].
Antoine, V; Belmin, J; Blain, H; Bonin-Guillaume, S; Goldsmith, L; Guerin, O; Kergoat, M-J; Landais, P; Mahmoudi, R; Morais, J A; Rataboul, P; Saber, A; Sirvain, S; Wolfklein, G; de Wazieres, B
2018-05-01
The Confusion Assessment Method (CAM) is a validated key tool in clinical practice and research programs to diagnose delirium and assess its severity. There is no validated French version of the CAM training manual and coding guide (Inouye SK). The aim of this study was to establish a consensual French version of the CAM and its manual. Cross-cultural adaptation to achieve equivalence between the original version and a French adapted version of the CAM manual. A rigorous process was conducted including control of cultural adequacy of the tool's components, double forward and back translations, reconciliation, expert committee review (including bilingual translators with different nationalities, a linguist, highly qualified clinicians, methodologists) and pretesting. A consensual French version of the CAM was achieved. Implementation of the CAM French version in daily clinical practice will enable optimal diagnosis of delirium diagnosis and enhance communication between health professionals in French speaking countries. Validity and psychometric properties are being tested in a French multicenter cohort, opening up new perspectives for improved quality of care and research programs in French speaking countries. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Mazzoni, Simona; Bianchi, Alberto; Schiariti, Giulio; Badiali, Giovanni; Marchetti, Claudio
2015-04-01
The purpose of the present study was to develop a computer-aided design (CAD) and computer-aided manufacturing (CAM) technique that enabled fabrication of surgical cutting guides and titanium fixation plates that would allow the upper maxilla to be repositioned correctly without a surgical splint in orthognathic patients. Ten patients were recruited. A complete CAD-CAM workflow for orthognathic surgery has 3 steps: 1) virtual planning of the surgical treatment, 2) CAD-CAM and 3-dimensional printing of customized surgical devices (surgical cutting guide and titanium fixation plates), and 3) computer-aided surgery. Upper maxilla repositioning was performed in a waferless manner using a CAD-CAM device: the surgical cutting guide was used during surgery to pilot the osteotomy line that had been planned preoperatively at the computer and the custom-made fixation titanium plates allowed desired repositioning of the maxilla. To evaluate the reproducibility of this CAD-CAM orthognathic surgical method, the virtually planned and actually achieved positions of the upper maxilla were compared. Overlap errors using a threshold value smaller than 2 mm were evaluated, and the frequency of such errors was used as a measurement of accuracy. By this definition, the accuracy was 100% in 7 patients (range in all patients, 62 to 100%; median, 92.7%). These results tend to confirm that the use of CAD-CAM cutting guides and customized titanium plates for upper maxilla repositioning represents a promising method for the accurate reproduction of preoperative virtual planning without the use of surgical splints. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Fouladbakhsh, Judith M; Stommel, Manfred
2010-01-01
To identify relationships among gender, physical and psychological symptoms (pain, insomnia, fatigue, and depression), and use of specific complementary and alternative medicine (CAM) practices among survivors in the U.S. cancer population. Secondary analysis of the 2002 National Health Interview Survey (NHIS). The CAM Healthcare Model, an extension of the Behavioral Model for Health Services Use, guided the study. United States. 2,262 adults (aged 18 years and older) diagnosed with cancer representing more than 14.3 million cancer survivors in the United States . NHIS interview data on use of CAM practices (diet, yoga, tai chi, qigong, meditation, guided imagery, relaxation, and deep breathing) were examined in relationship to gender and symptoms. Analysis was conducted using Stata 9.2 software for population estimation. Binary logistic regression, the primary statistical model employed in the analysis, focused on between-subject differences in practice use. Dichotomous outcome variables included use of at least one CAM practice and use of specific individual CAM practices. Independent variables included gender, age, education, race, provider contact, cancer diagnosis, pain, insomnia, fatigue, depression, and health status. CAM practice use was more prevalent among female, middle-aged, Caucasian, and well-educated subjects. Pain, depression, and insomnia were strong predictors of practice use, with differences noted by gender and practice type. CAM practices are widely used in the U.S. cancer population, especially among women. Symptom experience influences likelihood of use, with increased odds when men report symptoms. Study findings inform oncology nurses on the benefits of integrating self-care CAM practices in relationship to gender into the symptom management care plan for cancer survivors. Findings reported in this study will help guide future CAM practice intervention studies.
ERIC Educational Resources Information Center
Versnik Nowak, Amy L.; DeGise, Joe; Daugherty, Amanda; O'Keefe, Richard; Seward, Samuel, Jr.; Setty, Suma; Tang, Fanny
2015-01-01
Objective: Determine prevalence and types of complementary and alternative medicine (CAM) therapies used and test the significance of demographics and social cognitive constructs as predictors of CAM use in a college sample. Secondary purpose was to guide the integration of CAM therapies into college health services. Participants: Random,…
Singh, Renu F.; Best, Brookie M.; Freedman, Beverley A.; Morello, Candis M.
2012-01-01
Objective. To design and implement a small-group self-guided active-learning format for a complementary and alternative medicine (CAM) curriculum, and assess changes in first-year doctor of pharmacy (PharmD) students' attitudes and knowledge of CAM. Design. Students received an overview CAM lecture from a faculty member, and brief presentations with defined parameters on natural products from their peers. Assessment. Based on pre- and post-intervention survey responses, the percentage of students who strongly agreed about the importance of CAM in pharmacy practice increased from 28% to 55% and the percentage of students who agreed or strongly agreed about the harmful effects of dietary supplements increased from 60% to 96%. Overall, students' attitude toward and self-assessed knowledge of dietary supplements improved significantly from pre- to post-intervention survey. Conclusion. Small-group self-guided learning of CAM, followed by peer presentations on dietary supplements, was successful in significantly improving pharmacy students' attitude toward and knowledge of CAM. PMID:22919089
Atayee, Rabia S; Singh, Renu F; Best, Brookie M; Freedman, Beverley A; Morello, Candis M
2012-08-10
To design and implement a small-group self-guided active-learning format for a complementary and alternative medicine (CAM) curriculum, and assess changes in first-year doctor of pharmacy (PharmD) students' attitudes and knowledge of CAM. Students received an overview CAM lecture from a faculty member, and brief presentations with defined parameters on natural products from their peers. Based on pre- and post-intervention survey responses, the percentage of students who strongly agreed about the importance of CAM in pharmacy practice increased from 28% to 55% and the percentage of students who agreed or strongly agreed about the harmful effects of dietary supplements increased from 60% to 96%. Overall, students' attitude toward and self-assessed knowledge of dietary supplements improved significantly from pre- to post-intervention survey. Small-group self-guided learning of CAM, followed by peer presentations on dietary supplements, was successful in significantly improving pharmacy students' attitude toward and knowledge of CAM.
Morita, Daiki; Numajiri, Toshiaki; Tsujiko, Shoko; Nakamura, Hiroko; Yamochi, Ryo; Sowa, Yoshihiro; Yasuda, Makoto; Hirano, Shigeru
2017-11-01
Computer-aided design/computer-aided manufacturing (CAD/CAM) guides are now widely used in maxillofacial reconstruction. However, there are few reports of CAD/CAM guides being used for scapular flaps. The authors performed the secondary maxillary and orbital floor reconstruction using a free latissimus dorsi muscle, cutaneous tissue, and scapular flap designed using CAD/CAM techniques in a 72-year-old man who had undergone partial maxillectomy four years previously. The patient had diplopia, the vertical dystopia of eye position, and a large oral-nasal-cutaneous fistula. After the operation, the authors confirmed that the deviation between the postoperative and preoperative planning three-dimensional images was less than 2 mm. Because scapular guides require 3 cutting surfaces, the shape of the scapular guide is more complex than that of a conventional fibular guide. In orbital floor reconstruction, the use of a CAM technique such as that used to manufacture the authors' fixation guide is as necessary for accurate, safe, and easy reconstruction as is preoperative CAD planning. The production of a fixation guide as well as a cutting guide is particularly useful because it is difficult to determine the angle for reconstructing the orbital floor by freehand techniques. In this case, the orbital floor was reconstructed based on a mirror image of the healthy side to avoid overcompression of the orbital tissue. Although the patient's vertical dystopia of eye position was improved, diplopia was not improved because, for greater safety, the authors did not plan overcorrection of the orbital volume.
Arunyanak, Sirikarn P; Harris, Bryan T; Grant, Gerald T; Morton, Dean; Lin, Wei-Shao
2016-07-01
This report describes a digital approach for computer-guided surgery and immediate provisionalization in a partially edentulous patient. With diagnostic data obtained from cone-beam computed tomography and intraoral digital diagnostic scans, a digital pathway of virtual diagnostic waxing, a virtual prosthetically driven surgical plan, a computer-aided design and computer-aided manufacturing (CAD/CAM) surgical template, and implant-supported screw-retained interim restorations were realized with various open-architecture CAD/CAM systems. The optional CAD/CAM diagnostic casts with planned implant placement were also additively manufactured to facilitate preoperative inspection of the surgical template and customization of the CAD/CAM-fabricated interim restorations. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
An overview of CAM: components and clinical uses.
Kiefer, David; Pitluk, Jessica; Klunk, Kathryn
2009-01-01
Complementary and alternative medicine (CAM), more recently known as integrative health or integrative medicine, is a diverse field comprising numerous treatments and practitioners of various levels of training. This review defines several of the main CAM modalities and reviews some of the research relevant to their clinical application. The goal is to provide healthcare providers with a basic understanding of CAM to start the incorporation of proven treatments into their clinical practice as well as guide them to working with CAM providers; ultimately, such knowledge is a fundamental part of a collaborative approach to optimal patient health and wellness.
Kristoffersen, Agnete E; Sirois, Fuschia M; Stub, Trine; Hansen, Anne Helen
2017-06-19
Engagement in healthy lifestyle behaviors, such as healthy diet and regular physical activity, are known to reduce the risk of developing coronary heart disease (CHD). Complementary and alternative medicine (CAM) is known to be associated with having a healthy lifestyle. The primary aim of this study was to examine the prevalence and predictors of CAM use in CHD patients, and in those without CHD but at risk for developing CHD, using Protection Motivation Theory (PMT) as a guiding conceptual framework. Questionnaire data were collected from 12,981 adult participants in the cross-sectional sixth Tromsø Study (2007-8). Eligible for analyses were 11,103 participants who reported whether they had used CAM or not. Of those, 830 participants reported to have or have had CHD (CHD group), 4830 reported to have parents, children or siblings with CHD (no CHD but family risk), while 5443 reported no CHD nor family risk of CHD. We first compared the patterns of CAM use in each group, and then examined the PMT predictors of CAM use. Health vulnerability from the threat appraisal process of PMT was assessed by self-rated health and expectations for future health. Response efficacy from the coping appraisal process of PMT was assessed as preventive health beliefs and health behavior frequency. Use of CAM was most commonly seen in people with no CHD themselves, but family risk of developing CHD (35.8%), compared to people already diagnosed with CHD (30.2%) and people with no CHD nor family risk (32.1%). All four of the PMT factors; self-rated health, expectations for future health, preventive health beliefs, and the health behavior index - were predictors for CAM use in the no CHD but family risk group. These findings suggest that people use CAM in response to a perceived risk of developing CHD, and to prevent disease and to maintain health.
CAD/CAM-produced surgical guides: Optimizing the treatment workflow.
Neugebauer, J; Kistler, F; Kistler, S; Züdorf, G; Freyer, D; Ritter, L; Dreiseidler, T; Kusch, J; Zöller, J E
2011-01-01
The increased availability of devices for 3D radiological diagnosis allows the more frequent use of CAD/CAM-produced surgical guides for implant placement. The conventional workflow requires a complex logistic chain which is time-consuming and costly. In a pilot study, the workflow of directly milled surgical guides was evaluated. These surgical guides were designed based on the fusion of an optical impression and the radiological data. The clinical use showed that the surgical guides could be accurately placed on the residual dentition without tipping movements. The conventional surgical guides were used as a control for the manual check of the deviation of the implant axis. The direct transfer of the digital planning data allows the fabrication of surgical guides in an external center without the need of physical transport, which reduces the logistic effort and expense of the central fabrication of surgical guides.
Holmes, Michelle M; Bishop, Felicity L; Calman, Lynn
2017-08-01
Breast cancer survivors often turn to the internet as an information resource when deciding whether to use complementary and alternative medicine (CAM) but their use of online CAM-related resources is poorly understood. The objective was to explore breast cancer survivors' use of the internet when making decisions about CAM use. A purposive sample of 11 breast cancer survivors (mean age=56) completed a quantitative questionnaire and a qualitative telephone interview. The theory of planned behaviour (TPB) was used to guide interview questions. Framework analysis and descriptive statistics were used. United Kingdom. All participants found information on CAM using the internet and used some form of CAM after their diagnosis. Themes from the interviews went beyond the standard definitions of the TPB areas. Despite the lack of approval from their social network and healthcare team, participants used the internet to find information on CAM. Further, participants' cancer diagnosis changed their needs, transforming how they perceived and experienced the internet CONCLUSIONS: Participants' use of the internet was more complex than can easily be explained by the TPB and was inherently connected to the experience of self-management for the consequences of cancer and its treatment. As breast cancer survivors may not disclose their use of the internet to their healthcare team, healthcare professionals need to be aware that the information available on the internet plays a factor in the decision-making process to use CAM. Copyright © 2017 Elsevier Ltd. All rights reserved.
A short guide to peer-reviewed, MEDLINE-indexed complementary and alternative medicine journals.
Morgan, Sherry; Littman, Lynn; Palmer, Christina; Singh, Gurneet; LaRiccia, Patrick J
2012-01-01
Complementary and alternative medicine (CAM) comprises a multitude of disciplines, for example, acupuncture, ayurvedic medicine, biofeedback, herbal medicine, and homeopathic medicine. While research on CAM interventions has increased and the CAM literature has proliferated since the mid-1990s, a number of our colleagues have expressed difficulties in deciding where to publish CAM articles. In response, we created a short guide to peer-reviewed MEDLINE-indexed journals that publish CAM articles. We examined numerous English-language sources to identify titles that met our criteria, whether specific to or overlapping CAM. A few of the resources in which we found the journal titles that we included are Alternative Medicine Foundation, American Holistic Nurses Association, CINAHL/Nursing Database, Journal Citation Reports database, MEDLINE, PubMed, and Research Council for Complementary Medicine. We organized the 69 selected titles for easy use by creating 2 user-friendly tables, one listing titles in alphabetical order and one listing them in topical categories. A few examples of the topical categories are Acupuncture, CAM (general), Chinese Medicine, Herbal/Plant/Phytotherapy, Neuroscience/Psychology, Nursing/Clinical Care. Our study is the first to list general CAM journals, specialty CAM journals, and overlapping mainstream journals that are peer reviewed, in English, and indexed in MEDLINE. Our goal was to assist both authors seeking publication and mainstream journal editors who receive an overabundance of publishable articles but must recommend that authors seek publication elsewhere due to space and priority issues. Publishing in journals indexed by and included in MEDLINE (or PubMed) ensures that citations to articles will be found easily. Copyright © 2012 Lippincott Williams & Wilkins.
Jones, Desiree; Cohen, Lorenzo; Rieber, Alyssa G; Urbauer, Diana; Fellman, Bryan; Fisch, Michael J; Nazario, Arlene
2018-06-01
Complementary and alternative medicine (CAM) use in minority and medically underserved oncology patients is not well documented. We assessed knowledge and utilization of CAM in a sample of these patients receiving treatment at an urban community hospital. Patients with cancer were interviewed using an electronic application that depicted specific CAM therapies. Patients were questioned on their knowledge and utilization of therapies, deterrents to use, and interest in using these therapies if they were made available. Patients (n = 165) reported a high awareness and use of CAM therapies. CAM use was highest for prayer (85%), relaxation (54%), special diet (29%), meditation (19%), and massage (18%). Patients' interest in using CAM was high for nearly all therapies. Lack of adequate knowledge and cost of use were reported as deterrents to use. Female patients reported higher use of aromatherapy relative to males (37.1% vs 19.4%, P = .02); those with higher education reported greater use of relaxation (60.8% vs 28.6%, P = .02); non-Hispanics reported higher use of relaxation relative to Hispanics (63.5% vs 44.2%, P = .03), and African American patients reported higher use of relaxation relative to White patients (69.2% vs 50%, P = .03). CAM use in minority and medically underserved cancer patients is common, but not professionally guided; thus, concerns remain regarding its safe use. Our data underscore the importance of patient-physician dialogue regarding CAM use in this patient population, and interest in access to the medically guided integration of evidence-based CAM therapies.
Proussaefs, Periklis
2016-11-01
This article describes a technique in which a custom-made computer-aided design and computer-aided manufacturing (CAD-CAM) healing abutment milled from a poly(methyl methacrylate) (PMMA) block is fabricated and bonded to a titanium metal insert. An impression is made during dental implant surgery, and the CAD-CAM custom-made healing abutment is fabricated before second-stage surgery while appropriate healing time is allowed for the dental implant to osseointegrate. The contours of the healing abutment are based on the contours of a tentatively designed definitive prosthesis. The healing tissue obtains contours that will be compatible with the contours of the definitive prosthesis. After the milling process is complete, a titanium metal insert is bonded to the healing abutment. Placement of the custom-made CAD-CAM healing abutment at second-stage surgery allows the tissue to obtain contours similar to those of the definitive prosthesis. A custom-made CAD-CAM impression coping milled from a PMMA block and with a titanium insert is used for the definitive impression after the soft tissue has healed. This technique allows guided soft tissue healing by using a custom-made CAD-CAM healing abutment and impression coping. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Cultural Accommodation Model of Counseling
ERIC Educational Resources Information Center
Leong, Frederick T. L.
2011-01-01
The current article provides an overview to the cultural accommodation model (CAM) of counseling (Leong & Lee, 2006) that may help guide employment counselors' work. The integrative multidimensional model of cross-cultural counseling (Leong, 1996), a precursor to the CAM, is also reviewed.
Häuser, Winfried; Dobos, Gustav; Langhorst, Jost
2015-01-01
Objectives. This systematic overview of reviews aimed to summarize evidence and methodological quality from systematic reviews of complementary and alternative medicine (CAM) for the fibromyalgia syndrome (FMS). Methods. The PubMed/MEDLINE, Cochrane Library, and Scopus databases were screened from their inception to Sept 2013 to identify systematic reviews and meta-analyses of CAM interventions for FMS. Methodological quality of reviews was rated using the AMSTAR instrument. Results. Altogether 25 systematic reviews were found; they investigated the evidence of CAM in general, exercised-based CAM therapies, manipulative therapies, Mind/Body therapies, acupuncture, hydrotherapy, phytotherapy, and homeopathy. Methodological quality of reviews ranged from lowest to highest possible quality. Consistently positive results were found for tai chi, yoga, meditation and mindfulness-based interventions, hypnosis or guided imagery, electromyogram (EMG) biofeedback, and balneotherapy/hydrotherapy. Inconsistent results concerned qigong, acupuncture, chiropractic interventions, electroencephalogram (EEG) biofeedback, and nutritional supplements. Inconclusive results were found for homeopathy and phytotherapy. Major methodological flaws included missing details on data extraction process, included or excluded studies, study details, and adaption of conclusions based on quality assessment. Conclusions. Despite a growing body of scientific evidence of CAM therapies for the management of FMS systematic reviews still show methodological flaws limiting definite conclusions about their efficacy and safety. PMID:26246841
Lauche, Romy; Cramer, Holger; Häuser, Winfried; Dobos, Gustav; Langhorst, Jost
2015-01-01
Objectives. This systematic overview of reviews aimed to summarize evidence and methodological quality from systematic reviews of complementary and alternative medicine (CAM) for the fibromyalgia syndrome (FMS). Methods. The PubMed/MEDLINE, Cochrane Library, and Scopus databases were screened from their inception to Sept 2013 to identify systematic reviews and meta-analyses of CAM interventions for FMS. Methodological quality of reviews was rated using the AMSTAR instrument. Results. Altogether 25 systematic reviews were found; they investigated the evidence of CAM in general, exercised-based CAM therapies, manipulative therapies, Mind/Body therapies, acupuncture, hydrotherapy, phytotherapy, and homeopathy. Methodological quality of reviews ranged from lowest to highest possible quality. Consistently positive results were found for tai chi, yoga, meditation and mindfulness-based interventions, hypnosis or guided imagery, electromyogram (EMG) biofeedback, and balneotherapy/hydrotherapy. Inconsistent results concerned qigong, acupuncture, chiropractic interventions, electroencephalogram (EEG) biofeedback, and nutritional supplements. Inconclusive results were found for homeopathy and phytotherapy. Major methodological flaws included missing details on data extraction process, included or excluded studies, study details, and adaption of conclusions based on quality assessment. Conclusions. Despite a growing body of scientific evidence of CAM therapies for the management of FMS systematic reviews still show methodological flaws limiting definite conclusions about their efficacy and safety.
Harris, Bryan T; Montero, Daniel; Grant, Gerald T; Morton, Dean; Llop, Daniel R; Lin, Wei-Shao
2017-02-01
This clinical report proposes a digital workflow using 2-dimensional (2D) digital photographs, a 3D extraoral facial scan, and cone beam computed tomography (CBCT) volumetric data to create a 3D virtual patient with craniofacial hard tissue, remaining dentition (including surrounding intraoral soft tissue), and the realistic appearance of facial soft tissue at an exaggerated smile under static conditions. The 3D virtual patient was used to assist the virtual diagnostic tooth arrangement process, providing patient with a pleasing preoperative virtual smile design that harmonized with facial features. The 3D virtual patient was also used to gain patient's pretreatment approval (as a communication tool), design a prosthetically driven surgical plan for computer-guided implant surgery, and fabricate the computer-aided design and computer-aided manufacturing (CAD-CAM) interim prostheses. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Stapleton, Brandon M; Lin, Wei-Shao; Ntounis, Athanasios; Harris, Bryan T; Morton, Dean
2014-09-01
This clinical report demonstrated the use of an implant-supported fixed dental prosthesis fabricated with a contemporary digital approach. The digital diagnostic data acquisition was completed with a digital diagnostic impression with an intraoral scanner and cone-beam computed tomography with a prefabricated universal radiographic template to design a virtual prosthetically driven implant surgical plan. A surgical template fabricated with computer-aided design and computer-aided manufacturing (CAD/CAM) was used to perform computer-guided implant surgery. The definitive digital data were then used to design the definitive CAD/CAM-fabricated fixed dental prosthesis. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Marchack, Christopher B; Charles, Allan; Pettersson, Andreas
2011-12-01
The traditional technique for creating a CAD/CAM surgical template with a NobelGuide protocol is to fabricate a radiographic template that depicts the planned tooth position first. Multiple appointments are needed for the fabrication of the radiographic template with Cone Beam Computed Tomography (CBCT) before the surgical procedure can start. An alternative technique is described for fabricating a radiographic template at the initial examination appointment and capturing the necessary DICOM data to plan and fabricate a CAD/CAM surgical template in a 1-appointment protocol, thereby saving the patient and clinician time and reducing the need for multiple appointments. Copyright © 2011 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.
Complementary and conventional medicine: a concept map
Baldwin, Carol M; Kroesen, Kendall; Trochim, William M; Bell, Iris R
2004-01-01
Background Despite the substantive literature from survey research that has accumulated on complementary and alternative medicine (CAM) in the United States and elsewhere, very little research has been done to assess conceptual domains that CAM and conventional providers would emphasize in CAM survey studies. The objective of this study is to describe and interpret the results of concept mapping with conventional and CAM practitioners from a variety of backgrounds on the topic of CAM. Methods Concept mapping, including free sorts, ratings, and multidimensional scaling was used to organize conceptual domains relevant to CAM into a visual "cluster map." The panel consisted of CAM providers, conventional providers, and university faculty, and was convened to help formulate conceptual domains to guide the development of a CAM survey for use with United States military veterans. Results Eight conceptual clusters were identified: 1) Self-assessment, Self-care, and Quality of Life; 2) Health Status, Health Behaviors; 3) Self-assessment of Health; 4) Practical/Economic/ Environmental Concerns; 5) Needs Assessment; 6) CAM vs. Conventional Medicine; 7) Knowledge of CAM; and 8) Experience with CAM. The clusters suggest panelists saw interactions between CAM and conventional medicine as a critical component of the current medical landscape. Conclusions Concept mapping provided insight into how CAM and conventional providers view the domain of health care, and was shown to be a useful tool in the formulation of CAM-related conceptual domains. PMID:15018623
Methodological Issues in Trials of Complementary and Alternative Medicine Interventions
Sikorskii, Alla; Wyatt, Gwen; Victorson, David; Faulkner, Gwen; Rahbar, Mohammad Hossein
2010-01-01
Background Complementary and alternative medicine (CAM) use is widespread among cancer patients. Information on safety and efficacy of CAM therapies is needed for both patients and health care providers. Well-designed randomized clinical trials (RCTs) of CAM therapy interventions can inform both clinical research and practice. Objectives To review important issues that affect the design of RCTs for CAM interventions. Methods Using the methods component of the Consolidated Standards for Reporting Trials (CONSORT) as a guiding framework, and a National Cancer Institute-funded reflexology study as an exemplar, methodological issues related to participants, intervention, objectives, outcomes, sample size, randomization, blinding, and statistical methods were reviewed. Discussion Trials of CAM interventions designed and implemented according to appropriate methodological standards will facilitate the needed scientific rigor in CAM research. Interventions in CAM can be tested using proposed methodology, and the results of testing will inform nursing practice in providing safe and effective supportive care and improving the well-being of patients. PMID:19918155
Patel, Neal M.; Kinzer-Ursem, Tamara L.
2017-01-01
A number of neurological disorders arise from perturbations in biochemical signaling and protein complex formation within neurons. Normally, proteins form networks that when activated produce persistent changes in a synapse’s molecular composition. In hippocampal neurons, calcium ion (Ca2+) flux through N-methyl-D-aspartate (NMDA) receptors activates Ca2+/calmodulin signal transduction networks that either increase or decrease the strength of the neuronal synapse, phenomena known as long-term potentiation (LTP) or long-term depression (LTD), respectively. The calcium-sensor calmodulin (CaM) acts as a common activator of the networks responsible for both LTP and LTD. This is possible, in part, because CaM binding proteins are “tuned” to different Ca2+ flux signals by their unique binding and activation dynamics. Computational modeling is used to describe the binding and activation dynamics of Ca2+/CaM signal transduction and can be used to guide focused experimental studies. Although CaM binds over 100 proteins, practical limitations cause many models to include only one or two CaM-activated proteins. In this work, we view Ca2+/CaM as a limiting resource in the signal transduction pathway owing to its low abundance relative to its binding partners. With this view, we investigate the effect of competitive binding on the dynamics of CaM binding partner activation. Using an explicit model of Ca2+, CaM, and seven highly-expressed hippocampal CaM binding proteins, we find that competition for CaM binding serves as a tuning mechanism: the presence of competitors shifts and sharpens the Ca2+ frequency-dependence of CaM binding proteins. Notably, we find that simulated competition may be sufficient to recreate the in vivo frequency dependence of the CaM-dependent phosphatase calcineurin. Additionally, competition alone (without feedback mechanisms or spatial parameters) could replicate counter-intuitive experimental observations of decreased activation of Ca2+/CaM-dependent protein kinase II in knockout models of neurogranin. We conclude that competitive tuning could be an important dynamic process underlying synaptic plasticity. PMID:29107982
Anouti, Bilal; Haibe, Yolla
2017-01-01
Patients with lung cancer are increasingly seeking complementary and alternative medicine (CAM) to improve their physiological and psychological well-being. This study aimed to assess CAM use among lung cancer patients in Lebanon. Using a cross-sectional design, 150 lung cancer patients attending the Basile Cancer Institute at the American University of Beirut Medical Center were interviewed. Participants completed a questionnaire addressing sociodemographic characteristics, lung cancer condition, and use of CAM. The main outcome of interest was “use of any CAM therapy since diagnosis.” Prevalence of CAM use was 41%. The most commonly used CAM modality among study participants was “dietary supplements/special foods.” Results of the multiple logistic regression analyses showed that CAM use was positively associated with Lebanese nationality and paying for treatment out of pocket and was negatively associated with unemployment and having other chronic diseases. About 10% of patients used CAM on an alternative base, 58% did not disclose CAM use to their physician, and only 2% cited health professionals as influencing their choice of CAM. This study revealed a prevalent CAM use among lung cancer patients in Lebanon, with a marginal role for physicians in guiding this use. Promoting an open-communication and a patient-centered approach regarding CAM use is warranted. PMID:28912824
Park, Kellie A; Ribic, Adema; Laage Gaupp, Fabian M; Coman, Daniel; Huang, Yuegao; Dulla, Chris G; Hyder, Fahmeed; Biederer, Thomas
2016-07-13
Select adhesion proteins control the development of synapses and modulate their structural and functional properties. Despite these important roles, the extent to which different synapse-organizing mechanisms act across brain regions to establish connectivity and regulate network properties is incompletely understood. Further, their functional roles in different neuronal populations remain to be defined. Here, we applied diffusion tensor imaging (DTI), a modality of magnetic resonance imaging (MRI), to map connectivity changes in knock-out (KO) mice lacking the synaptogenic cell adhesion protein SynCAM 1. This identified reduced fractional anisotropy in the hippocampal CA3 area in absence of SynCAM 1. In agreement, mossy fiber refinement in CA3 was impaired in SynCAM 1 KO mice. Mossy fibers make excitatory inputs onto postsynaptic specializations of CA3 pyramidal neurons termed thorny excrescences and these structures were smaller in the absence of SynCAM 1. However, the most prevalent targets of mossy fibers are GABAergic interneurons and SynCAM 1 loss unexpectedly reduced the number of excitatory terminals onto parvalbumin (PV)-positive interneurons in CA3. SynCAM 1 KO mice additionally exhibited lower postsynaptic GluA1 expression in these PV-positive interneurons. These synaptic imbalances in SynCAM 1 KO mice resulted in CA3 disinhibition, in agreement with reduced feedforward inhibition in this network in the absence of SynCAM 1-dependent excitatory drive onto interneurons. In turn, mice lacking SynCAM 1 were impaired in memory tasks involving CA3. Our results support that SynCAM 1 modulates excitatory mossy fiber inputs onto both interneurons and principal neurons in the hippocampal CA3 area to balance network excitability. This study advances our understanding of synapse-organizing mechanisms on two levels. First, the data support that synaptogenic proteins guide connectivity and can function in distinct brain regions even if they are expressed broadly. Second, the results demonstrate that a synaptogenic process that controls excitatory inputs to both pyramidal neurons and interneurons can balance excitation and inhibition. Specifically, the study reveals that hippocampal CA3 connectivity is modulated by the synapse-organizing adhesion protein SynCAM 1 and identifies a novel, SynCAM 1-dependent mechanism that controls excitatory inputs onto parvalbumin-positive interneurons. This enables SynCAM 1 to regulate feedforward inhibition and set network excitability. Further, we show that diffusion tensor imaging is sensitive to these cellular refinements affecting neuronal connectivity. Copyright © 2016 the authors 0270-6474/16/367465-12$15.00/0.
GOOSE CAM: The Development of a Practical Underwater Exploration Platform
ERIC Educational Resources Information Center
Miller, William R.; Mitchell, Colleen; Miller, Jeffrey D.
2009-01-01
We challenged an Aquatic Biology class to find a way to access, observe, and record aquatic habitats and organisms without causing disruption. Using off the shelf components the class was guided in the design and assembly of a remote controlled, video broadcasting, data collecting, floating vehicle based on a molded goose decoy. GOOSE-CAM or…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ge Jin; Fishman, Jessica; Annenberg School for Communication at University of Pennsylvania, University of Pennsylvania Health System, Philadelphia, Pennsylvania
Purpose: Despite the extensive use of complementary and alternative medicine (CAM) among cancer patients, patient-physician communication regarding CAM therapies remains limited. This study quantified the extent of patient-physician communication about CAM and identified factors associated with its discussion in radiation therapy (RT) settings. Methods and Materials: We conducted a cross-sectional survey of 305 RT patients at an urban academic cancer center. Patients with different cancer types were recruited in their last week of RT. Participants self-reported their demographic characteristics, health status, CAM use, patient-physician communication regarding CAM, and rationale for/against discussing CAM therapies with physicians. Multivariate logistic regression was usedmore » to identify relationships between demographic/clinical variables and patients' discussion of CAM with radiation oncologists. Results: Among the 305 participants, 133 (43.6%) reported using CAM, and only 37 (12.1%) reported discussing CAM therapies with their radiation oncologists. In multivariate analyses, female patients (adjusted odds ratio [AOR] 0.45, 95% confidence interval [CI] 0.21-0.98) and patients with full-time employment (AOR 0.32, 95% CI 0.12-0.81) were less likely to discuss CAM with their radiation oncologists. CAM users (AOR 4.28, 95% CI 1.93-9.53) were more likely to discuss CAM with their radiation oncologists than were non-CAM users. Conclusions: Despite the common use of CAM among oncology patients, discussions regarding these treatments occur rarely in the RT setting, particularly among female and full-time employed patients. Clinicians and patients should incorporate discussions of CAM to guide its appropriate use and to maximize possible benefit while minimizing potential harm.« less
Finelle, Gary; Lee, Sang J
Digital technology has been widely used in the field of implant dentistry. From a surgical standpoint, computer-guided surgery can be utilized to enhance primary implant stability and to improve the precision of implant placement. From a prosthetic standpoint, computer-aided design/computer-assisted manufacture (CAD/CAM) technology has brought about various restorative options, including the fabrication of customized abutments through a virtual design based on computer-guided surgical planning. This case report describes a novel technique combining the use of a three-dimensional (3D) printed surgical template for the immediate placement of an implant, with CAD/CAM technology to optimize hard and soft tissue healing after bone grafting with the use of a socket sealing abutment.
Mercurio, Reegan; Eliott, Jaklin Ardath
2011-01-01
Many cancer patients within developed nations cite the media as informing their decisions to use complementary and alternative medicine (CAM). The present study describes (1) Australian newspaper coverage of CAM use for cancer between 1998 and 2007; (2) trends in reporting frequency and characteristics; and (3) how the Australian press framed stories on CAM use for cancer. This study is a content analysis featuring quantitative and qualitative techniques, the latter guided by 'media framing', of targeted newspaper articles. One hundred nineteen articles focused on CAM use for the treatment of cancer were identified. Quantitative analysis found that biologically based CAMs were most frequently described and breast cancer most mentioned. Two thirds of all articles described CAM use in the context of a cure, with approximately half of these opposing this reason for use. Potential benefits of CAM were discussed more frequently than potential risks, and information on costs and how to access CAM were uncommon. Recommendations included advice to use complementary, not alternative therapies, yet advice to discuss CAM with a medical doctor was rare. Qualitative analysis found six CAM cancer-related frames, four in support of CAM use for cancer treatment. The dominant frame constructed CAM as legitimate tools to assist biomedicine (even to cure), with others depicting CAM as normal and necessary or as addressing limitations of biomedicine. Negative frames depicted CAM as questionable and risky practices and the industry/practitioners as possessing malevolent intent. These findings have implications for biomedical practitioners attempting to determine, respect and assist patient choices about their treatment.
Xi-cam: Flexible High Throughput Data Processing for GISAXS
NASA Astrophysics Data System (ADS)
Pandolfi, Ronald; Kumar, Dinesh; Venkatakrishnan, Singanallur; Sarje, Abinav; Krishnan, Hari; Pellouchoud, Lenson; Ren, Fang; Fournier, Amanda; Jiang, Zhang; Tassone, Christopher; Mehta, Apurva; Sethian, James; Hexemer, Alexander
With increasing capabilities and data demand for GISAXS beamlines, supporting software is under development to handle larger data rates, volumes, and processing needs. We aim to provide a flexible and extensible approach to GISAXS data treatment as a solution to these rising needs. Xi-cam is the CAMERA platform for data management, analysis, and visualization. The core of Xi-cam is an extensible plugin-based GUI platform which provides users an interactive interface to processing algorithms. Plugins are available for SAXS/GISAXS data and data series visualization, as well as forward modeling and simulation through HipGISAXS. With Xi-cam's advanced mode, data processing steps are designed as a graph-based workflow, which can be executed locally or remotely. Remote execution utilizes HPC or de-localized resources, allowing for effective reduction of high-throughput data. Xi-cam is open-source and cross-platform. The processing algorithms in Xi-cam include parallel cpu and gpu processing optimizations, also taking advantage of external processing packages such as pyFAI. Xi-cam is available for download online.
Chui, Ping Lei; Abdullah, Khatijah Lim; Wong, Li Ping; Taib, Nur Aishah
Complementary and alternative medicine (CAM) is commonly used for cancer- and chemotherapy-related symptoms. Nurses are likely to encounter many CAM users in their practice. The aims of this study were to assess CAM use and examine the symptom burden of CAM and non-CAM users among patients with breast cancer who are undergoing chemotherapy. A CAM use questionnaire and the Side-Effect Burden Scale were administered to 546 patients. Complementary and alternative medicine use was categorized as mind-body practices (MBPs), natural products (NPs), or traditional medicine (TM). We identified 386 CAM users (70.7%) in this study. The CAM users reported a higher marginal mean total symptom burden score (40.39 ± 2.6) than non-CAM users (36.93 ± 3.21), although this difference was not statistically significant (P = .09). Triple-modality (MBP-NP-TM) CAM users had a significantly higher marginal mean total symptom burden score (47.44 ± 4.12) than single-modality (MBP) users (34.09 ± 4.43). The risk of having a high total symptom burden score was 12.9-fold higher among the MBP-NP-TM users than among the MBP users. Complementary and alternative medicine use is common among Malaysian patients who are undergoing chemotherapy for breast cancer. However, CAM and non-CAM users reported similar symptom burdens, although single-modality use of MBP is likely associated with a lower symptom burden. Nurses should keep abreast of current developments and trends in CAM use. Understanding CAM use and the related symptom burden will allow nurses to initiate open discussion and guide their patients in seeking additional information or referrals for a particular therapy.
ERIC Educational Resources Information Center
Georgia Univ., Athens. Div. of Vocational Education.
This guide describes the requirements for courses in computer-aided design and computer-aided manufacturing (CAD/CAM) that are part of engineering technology programs conducted in vocational-technical schools in Georgia. The guide is organized in five sections. The first section provides a rationale for occupations in design and in production,…
Chien, Shih-Chieh Jason; Gurling, Mark; Kim, Changsung; Craft, Teresa; Forrester, Wayne; Garriga, Gian
2015-01-01
Wnts are a conserved family of secreted glycoproteins that regulate various developmental processes in metazoans. Three of the five C. elegans Wnts, CWN-1, CWN-2 and EGL-20, and the sole Wnt receptor of the Ror kinase family, CAM-1, are known to regulate the anterior polarization of the mechanosensory neuron ALM. Here we show that CAM-1 and the Frizzled receptor MOM-5 act in parallel pathways to control ALM polarity. We also show that CAM-1 has two functions in this process: an autonomous signaling function that promotes anterior polarization and a nonautonomous Wnt-antagonistic function that inhibits anterior polarization. These antagonistic activities can account for the weak ALM phenotypes displayed by cam-1 mutants. Our observations suggest that CAM-1 could function as a Wnt receptor in many developmental processes, but the analysis of cam-1 mutants may fail to reveal CAM-1’s role as a receptor in these processes because of its Wnt-antagonistic activity. In this model, loss of CAM-1 results in increased levels of Wnts that act through other Wnt receptors, masking CAM-1’s autonomous role as a Wnt receptor. PMID:25917219
Song, In-Seok; Lee, Mi-Ran; Ryu, Jae-Jun; Lee, Ui-Lyong
Dental implants positioned in severely atrophied anterior maxillae require esthetic or functional compromises. This case report describes the rehabilitation of a severely atrophied alveolar ridge with a three-dimensional (3D) computer-aided design/computer-aided manufacture (CAD/CAM) surgical guide. A 50-year-old woman had a severely atrophied anterior maxilla with unfavorably positioned dental implants. Functional and esthetic prosthodontic restoration was difficult to achieve. An anterior segmental osteotomy was planned to reposition the dental implants. A 3D surgical guide was designed for precise relocation of the segment. The surgical guide firmly grasped the impression copings of the dental implants, minimizing surgical errors. Three-dimensional gingival simulation was used preoperatively to estimate the appropriate position of the gingiva. Rigid fixation to the surrounding bone allowed immobilization of the implant-bone segment. Satisfactory esthetic and functional outcomes were attained 6 months after surgery. Finally, a severely atrophied alveolar ridge with unfavorably positioned dental implants was recovered with minimal esthetic and functional deterioration using gingival simulation and a 3D CAD/CAM surgical guide.
Blume, Oliver; Hoffmann, Lisa; Donkiewicz, Phil; Wenisch, Sabine; Back, Michael; Franke, Jörg; Schnettler, Reinhard
2017-01-01
The objective of this case report is to introduce a customized CAD/CAM freeze-dried bone allograft (FDBA) block for its use in Guided Bone Regeneration (GBR) procedures for severely deficient maxillary bones. Additionally, a special newly developed remote incision technique is presented to avoid wound dehiscence. The results show optimal integration behavior of the FDBA block after six months and the formation of new vital bone. Thus, the results of the present case report confirm the use of the customized CAD/CAM bone block for augmentation of complex defects in the maxillary aesthetic zone as a successful treatment concept. PMID:29065477
Blume, Oliver; Hoffmann, Lisa; Donkiewicz, Phil; Wenisch, Sabine; Back, Michael; Franke, Jörg; Schnettler, Reinhard; Barbeck, Mike
2017-10-21
The objective of this case report is to introduce a customized CAD/CAM freeze-dried bone allograft (FDBA) block for its use in Guided Bone Regeneration (GBR) procedures for severely deficient maxillary bones. Additionally, a special newly developed remote incision technique is presented to avoid wound dehiscence. The results show optimal integration behavior of the FDBA block after six months and the formation of new vital bone. Thus, the results of the present case report confirm the use of the customized CAD/CAM bone block for augmentation of complex defects in the maxillary aesthetic zone as a successful treatment concept.
Integrating three-dimensional digital technologies for comprehensive implant dentistry.
Patel, Neal
2010-06-01
The increase in the popularity of and the demand for the use of dental implants to replace teeth has encouraged advancement in clinical technology and materials to improve patients' acceptance and clinical outcomes. Recent advances such as three-dimensional dental radiography with cone-beam computed tomography (CBCT), precision dental implant planning software and clinical execution with guided surgery all play a role in the success of implant dentistry. The author illustrates the technique of comprehensive implant dentistry planning through integration of computer-aided design/computer-aided manufacturing (CAD/CAM) and CBCT data. The technique includes clinical treatment with guided surgery, including the creation of a final restoration with a high-strength ceramic (IPS e.max CAD, Ivoclar Vivadent, Amherst, N.Y.). The author also introduces a technique involving CAD/CAM for fabricating custom implant abutments. The release of software integrating CEREC Acquisition Center with Bluecam (Sirona Dental Systems, Charlotte, N.C.) chairside CAD/CAM and Galileos CBCT imaging (Sirona Dental Systems) allows dentists to plan implant placement, perform implant dentistry with increased precision and provide predictable restorative results by using chairside IPS e.max CAD. The precision of clinical treatment provided by the integration of CAD/CAM and CBCT allows dentists to plan for ideal surgical placement and the appropriate thickness of restorative modalities before placing implants.
Different CAD/CAM-processing routes for zirconia restorations: influence on fitting accuracy.
Kohorst, Philipp; Junghanns, Janet; Dittmer, Marc P; Borchers, Lothar; Stiesch, Meike
2011-08-01
The aim of the present in vitro study was to evaluate the influence of different processing routes on the fitting accuracy of four-unit zirconia fixed dental prostheses (FDPs) fabricated by computer-aided design/computer-aided manufacturing (CAD/CAM). Three groups of zirconia frameworks with ten specimens each were fabricated. Frameworks of one group (CerconCAM) were produced by means of a laboratory CAM-only system. The other frameworks were made with different CAD/CAM systems; on the one hand by in-laboratory production (CerconCAD/CAM) and on the other hand by centralized production in a milling center (Compartis) after forwarding geometrical data. Frameworks were then veneered with the recommended ceramics, and marginal accuracy was determined using a replica technique. Horizontal marginal discrepancy, vertical marginal discrepancy, absolute marginal discrepancy, and marginal gap were evaluated. Statistical analyses were performed by one-way analysis of variance (ANOVA), with the level of significance chosen at 0.05. Mean horizontal discrepancies ranged between 22 μm (CerconCAM) and 58 μm (Compartis), vertical discrepancies ranged between 63 μm (CerconCAD/CAM) and 162 μm (CerconCAM), and absolute marginal discrepancies ranged between 94 μm (CerconCAD/CAM) and 181 μm (CerconCAM). The marginal gap varied between 72 μm (CerconCAD/CAM) and 112 μm (CerconCAM, Compartis). Statistical analysis revealed that, with all measurements, the marginal accuracy of the zirconia FDPs was significantly influenced by the processing route used (p < 0.05). Within the limitations of this study, all restorations showed a clinically acceptable marginal accuracy; however, the results suggest that the CAD/CAM systems are more precise than the CAM-only system for the manufacture of four-unit FDPs.
Effects of Gasoline Direct Injection Engine Operating Parameters on Particle Number Emissions
DOE Office of Scientific and Technical Information (OSTI.GOV)
He, X.; Ratcliff, M. A.; Zigler, B. T.
2012-04-19
A single-cylinder, wall-guided, spark ignition direct injection engine was used to study the impact of engine operating parameters on engine-out particle number (PN) emissions. Experiments were conducted with certification gasoline and a splash blend of 20% fuel grade ethanol in gasoline (E20), at four steady-state engine operating conditions. Independent engine control parameter sweeps were conducted including start of injection, injection pressure, spark timing, exhaust cam phasing, intake cam phasing, and air-fuel ratio. The results show that fuel injection timing is the dominant factor impacting PN emissions from this wall-guided gasoline direct injection engine. The major factor causing high PN emissionsmore » is fuel liquid impingement on the piston bowl. By avoiding fuel impingement, more than an order of magnitude reduction in PN emission was observed. Increasing fuel injection pressure reduces PN emissions because of smaller fuel droplet size and faster fuel-air mixing. PN emissions are insensitive to cam phasing and spark timing, especially at high engine load. Cold engine conditions produce higher PN emissions than hot engine conditions due to slower fuel vaporization and thus less fuel-air homogeneity during the combustion process. E20 produces lower PN emissions at low and medium loads if fuel liquid impingement on piston bowl is avoided. At high load or if there is fuel liquid impingement on piston bowl and/or cylinder wall, E20 tends to produce higher PN emissions. This is probably a function of the higher heat of vaporization of ethanol, which slows the vaporization of other fuel components from surfaces and may create local fuel-rich combustion or even pool-fires.« less
Breaking Boundaries: Complementary and Alternative Medicine Provider Framing of Preventive Care.
Agarwal, Vinita
2017-11-01
This textual examination extends understandings of how complementary and alternative medicine (CAM) providers constitute preventive care in their discourse by identifying the frame of breaking boundaries referencing relational, structural, and philosophical orientations in their practice with their clients. Analysis of semistructured, in-depth interviews with CAM providers ( n = 17) reveals that the frame of breaking boundaries was comprised of three themes: finding one's own strength; I don't prescribe, so I'm exploring; and ground yourself, and have an escape route. The themes describe preventive care by identifying how CAM providers negotiate their relational positionality in connecting with clients, structural positionality within the field of health care, and philosophical positionality within the ontological understandings that guide how health is defined and conceptualized. The study contributes toward enhancing diverse understandings of constituting preventive care in practice and suggests pragmatic implications for addressing biomedical provider communication with their patients seeking CAM care alongside conventional treatments.
Numerical Control/Computer Aided Manufacturing (NC/CAM), A Descom Study
1979-07-01
CAM machines operate directly from computers, but most get instructions in the form of punched tape. The applications of NC/CAM are virtually...Although most NC/CAM equipment is metal working, its applications include electronics manufacturing, glass making, food processing, materiel handling...drafting, woodworking, plastics and inspection, just to name a few. Numerical control, like most technologies, is an advancing and evolutionary process
Geng, Wei; Liu, Changying; Su, Yucheng; Li, Jun; Zhou, Yanmin
2015-01-01
Purpose: To evaluate the clinical outcomes of implants placed using different types of computer-aided design/computer-aided manufacturing (CAD/CAM) surgical guides, including partially guided and totally guided templates, and determine the accuracy of these guides Materials and methods: In total, 111 implants were placed in 24 patients using CAD/CAM surgical guides. After implant insertion, the positions and angulations of the placed implants relative to those of the planned ones were determined using special software that matched pre- and postoperative computed tomography (CT) images, and deviations were calculated and compared between the different guides and templates. Results: The mean angular deviations were 1.72 ± 1.67 and 2.71 ± 2.58, the mean deviations in position at the neck were 0.27 ± 0.24 and 0.69 ± 0.66 mm, the mean deviations in position at the apex were 0.37 ± 0.35 and 0.94 ± 0.75 mm, and the mean depth deviations were 0.32 ± 0.32 and 0.51 ± 0.48 mm with tooth- and mucosa-supported stereolithographic guides, respectively (P < .05 for all). The mean distance deviations when partially guided (29 implants) and totally guided templates (30 implants) were used were 0.54 ± 0.50 mm and 0.89 ± 0.78 mm, respectively, at the neck and 1.10 ± 0.85 mm and 0.81 ± 0.64 mm, respectively, at the apex, with corresponding mean angular deviations of 2.56 ± 2.23° and 2.90 ± 3.0° (P > .05 for all). Conclusions: Tooth-supported surgical guides may be more accurate than mucosa-supported guides, while both partially and totally guided templates can simplify surgery and aid in optimal implant placement. PMID:26309497
Klepal, Jaroslav; Stöckelová, Tereza
2018-06-20
Drawing on fieldwork in the postsocialist Czech Republic, we explore the transformative processes of biomedicalization, both within and in relation to complementary and alternative medicine (CAM). We argue that it would be simplistic to understand evidence of these processes in CAM as a sign that CAM has fallen prey to biomedicine. Instead, we show how particular CAM practices play a groundbreaking role in shaping developments in contemporary health care. In this respect, we question the utility of the concept of biomedicalization, arguing that it reduces the transformative processes to aspects of biomedicine.
Wauters, Lauri D J; Miguel-Moragas, Joan San; Mommaerts, Maurice Y
2015-11-01
To gain insight into the methodology of different computer-aided design-computer-aided manufacturing (CAD-CAM) applications for the reconstruction of cranio-maxillo-facial (CMF) defects. We reviewed and analyzed the available literature pertaining to CAD-CAM for use in CMF reconstruction. We proposed a classification system of the techniques of implant and cutting, drilling, and/or guiding template design and manufacturing. The system consisted of 4 classes (I-IV). These classes combine techniques used for both the implant and template to most accurately describe the methodology used. Our classification system can be widely applied. It should facilitate communication and immediate understanding of the methodology of CAD-CAM applications for the reconstruction of CMF defects.
IPAD: A unique approach to government/industry cooperation for technology development and transfer
NASA Technical Reports Server (NTRS)
Fulton, Robert E.; Salley, George C.
1985-01-01
A key element to improved industry productivity is effective management of Computer Aided Design / Computer Aided Manufacturing (CAD/CAM) information. To stimulate advancement, a unique joint government/industry project designated Integrated Programs for Aerospace-Vehicle Design (IPAD) was carried out from 1971 to 1984. The goal was to raise aerospace industry productivity through advancement of computer based technology to integrate and manage information involved in the design and manufacturing process. IPAD research was guided by an Industry Technical Advisory Board (ITAB) composed of over 100 representatives from aerospace and computer companies. The project complemented traditional NASA/DOD research to develop aerospace design technology and the Air Force's Integrated Computer Aided Manufacturing (ICAM) program to advance CAM technology. IPAD had unprecedented industry support and involvement and served as a unique approach to government industry cooperation in the development and transfer of advanced technology. The IPAD project background, approach, accomplishments, industry involvement, technology transfer mechanisms and lessons learned are summarized.
Comparison of denture tooth movement between CAD-CAM and conventional fabrication techniques.
Goodacre, Brian J; Goodacre, Charles J; Baba, Nadim Z; Kattadiyil, Mathew T
2018-01-01
Data comparing the denture tooth movement of computer-aided design and computer-aided manufacturing (CAD-CAM) and conventional denture processing techniques are lacking. The purpose of this in vitro study was to compare the denture tooth movement of pack-and-press, fluid resin, injection, CAD-CAM-bonded, and CAD-CAM monolithic techniques for fabricating dentures to determine which process produces the most accurate and reproducible prosthesis. A total of 50 dentures were evaluated, 10 for each of the 5 groups. A master denture was fabricated and milled from prepolymerized poly(methyl methacrylate). For the conventional processing techniques (pack-and-press, fluid resin, and injection) a polyvinyl siloxane putty mold of the master denture was made in which denture teeth were placed and molten wax injected. The cameo surface of each wax-festooned denture was laser scanned, resulting in a standard tessellation language (STL) format file. The CAD-CAM dentures included 2 subgroups: CAD-CAM-bonded teeth in which the denture teeth were bonded into the milled denture base and CAD-CAM monolithic teeth in which the denture teeth were milled as part of the denture base. After all specimens had been fabricated, they were hydrated for 24 hours, and the cameo surface laser scanned. The preprocessing and postprocessing scan files of each denture were superimposed using surface-matching software. Measurements were made at 64 locations, allowing evaluation of denture tooth movement in a buccal, lingual, mesial-distal, and occlusal direction. The use of median and interquartile range values was used to assess accuracy and reproducibility. Levene and Kruskal-Wallis analyses of variance were used to evaluate differences between processing techniques (α=.05). The CAD-CAM monolithic technique was the most accurate, followed by fluid resin, CAD-CAM-bonded, pack-and-press, and injection. CAD-CAM monolithic technique was the most reproducible, followed by pack-and-press, CAD-CAM-bonded, injection, and fluid resin. Techniques involving compression during processing showed increased positive occlusal tooth movement compared with techniques not involving compression. CAD-CAM monolithic dentures produced the best combination of accuracy and reproducibility of the tested techniques. The results from this study demonstrate that varying amounts of tooth movement can be expected depending on the processing technique. However, the clinical significance of these differences is unknown. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
2009-09-01
The on cell phone software captures the images from the CMOS camera periodically, stores the pictures, and periodically transmits those images over the cellular network to the server. The cell phone software consists of several modules: CamTest.cpp, CamStarter.cpp, StreamIOHandler .cpp, and covertSmartDevice.cpp. The camera application on the SmartPhone is CamStarter, which is "the" user interface for the camera system. The CamStarter user interface allows a user to start/stop the camera application and transfer files to the server. The CamStarter application interfaces to the CamTest application through registry settings. Both the CamStarter and CamTest applications must be separately deployed on themore » smartphone to run the camera system application. When a user selects the Start button in CamStarter, CamTest is created as a process. The smartphone begins taking small pictures (CAPTURE mode), analyzing those pictures for certain conditions, and saving those pictures on the smartphone. This process will terminate when the user selects the Stop button. The camtest code spins off an asynchronous thread, StreamIOHandler, to check for pictures taken by the camera. The received image is then tested by StreamIOHandler to see if it meets certain conditions. If those conditions are met, the CamTest program is notified through the setting of a registry key value and the image is saved in a designated directory in a custom BMP file which includes a header and the image data. When the user selects the Transfer button in the CamStarter user interface, the covertsmartdevice code is created as a process. Covertsmartdevice gets all of the files in a designated directory, opens a socket connection to the server, sends each file, and then terminates.« less
Montross-Thomas, Lori P; Meier, Emily A; Reynolds-Norolahi, Kimberly; Raskin, Erin E; Slater, Daniel; Mills, Paul J; MacElhern, Lauray; Kallenberg, Gene
2017-04-01
Research demonstrates the benefits of complementary and alternative medicine (CAM) in myriad environments. Yet, the majority of CAM services are offered in outpatient settings. Incorporating CAM into hospital settings may lead to increased patient comfort, well-being, and overall satisfaction with hospital admissions. Few studies have examined CAM services among inpatients. Therefore, this study assessed inpatients' preferences and beliefs regarding CAM, as well as their stated willingness to pay for these services. Adult patients (n = 100), ranging in age from 19-95 years (M = 53 years; SD = 19.2 years), were recruited during their hospitalization in the University of California, San Diego, Healthcare System. The inpatients completed a brief individual interview to gather their perspectives on common CAM services, including acupuncture, aromatherapy, art therapy, guided imagery, healthy food, humor therapy, massage therapy, music therapy, pet therapy, Reiki, and stress management. Inpatients were asked which CAM therapies they perceived as being potentially the most helpful, their willingness to pay for those therapies, and their perceived beliefs regarding the use of those therapies. Inpatients most commonly perceived healthy food (85%), massage therapy (82%), and humor therapy (70%) to be the most helpful, and were most willing to pay for healthy food (71%), massage therapy (70%), and stress management (48%). Inpatients most commonly believed CAM treatments would provide relaxation (88%), increase well-being (86%), and increase their overall satisfaction with the hospitalization (85%). This study suggests that CAM services may be a beneficial addition to hospitals, as demonstrated by inpatients' interest and stated willingness to pay for these services. These findings may help organizational leaders when making choices regarding the development of CAM services within hospitals, particularly since a significant percentage of inpatients reported that CAM services would increase their overall satisfaction with the hospitalization. These results merit further attention given the need to increase cost savings while enhancing the overall patient experience in today's medical marketplace.
Schiff, Elad; Ben-Arye, Eran; Shilo, Margalit; Levy, Moti; Schachter, Leora; Weitchner, Na'ama; Golan, Ofra; Stone, Julie
2010-11-01
The practice of complementary medicine (CAM) often involves touch. The unique philosophy of many CAM therapies, and the setting in which treatments are provided create a therapeutic space which may be less clearly defined than in conventional settings - a space in which the boundaries between professional touch and personal/intimate touch may become easily obscured. Thus, complementary therapists need clear definitions and firm boundaries in order to maintain therapeutic efficacy and commitment. The aim of the process described in this article, was to develop ethical guidelines for boundaries of touch that will promote the safety and protection of the public which use CAM. Through a modified Delphi process, a diverse group of CAM practitioners, physicians, ethicists, legal consultants, health policy specialists, and representatives from the public, developed Ethical Rules for Boundaries of Touch in CAM. These guidelines may be implemented in ethical codes of professional CAM organizations, and also serve as a foundation for curriculums in ethics in CAM schools. Copyright © 2010 Elsevier Ltd. All rights reserved.
Arocha, Mariana A; Basilio, Juan; Llopis, Jaume; Di Bella, Enrico; Roig, Miguel; Ardu, Stefano; Mayoral, Juan R
2014-07-01
The aim of this study was to determine, by using a spectrophotometer device, the colour stainability of two indirect CAD/CAM processed composites in comparison with two conventionally laboratory-processed composites after being immersed 4 weeks in staining solutions such as coffee, black tea and red wine, using distilled water as control group. Two indirect CAD/CAM composites (Lava Ultimate and Paradigm MZ100) and two conventionally laboratory-processed composites (SR Adoro and Premise Indirect) of shade A2 were selected (160 disc samples). Colour stainability was measured after 4 weeks of immersion in three staining solutions (black tea, coffee, red wine) and distilled water. Specimen's colour was measured each week by means of a spectrophotometer (CIE L*a*b* system). Statistical analysis was carried out performing repeated ANOVA measurements and Tukey's HSD test to evaluate differences in ΔE00 measurements between groups; the interactions among composites, staining solutions and time duration were also evaluated. All materials showed significant discoloration (p<0.01) when compared to control group. The highest ΔE00 observed was with red wine, whereas black tea showed the lowest one. Indirect laboratory-processed resin composites showed the highest colour stability compared with CAD/CAM resin blocks. CAD/CAM processed composites immersed in staining solutions showed lower colour stability when compared to conventionally laboratory-processed resin composites. The demand for CAD/CAM restorations has been increasing; however, colour stainability for such material has been insufficiently studied. Moreover, this has not been performed comparing CAD/CAM processed composites versus laboratory-processed indirect composites by immersing in staining solutions for long immersion periods. Copyright © 2014 Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Havas, George D.
This brief guide to materials in the Library of Congress (LC) on computer aided design and/or computer aided manufacturing lists reference materials and other information sources under 13 headings: (1) brief introductions; (2) LC subject headings used for such materials; (3) textbooks; (4) additional titles; (5) glossaries and handbooks; (6)…
Phang, Jie Kie; Kwan, Yu Heng; Goh, Hendra; Tan, Victoria Ie Ching; Thumboo, Julian; Østbye, Truls; Fong, Warren
2018-04-01
To summarize all good quality randomized controlled trials (RCTs) using complementary and alternative medicine (CAM) interventions in patients with rheumatic diseases. A systematic literature review guided by the Preferred Reporting Items for Systematic review and Meta-Analysis (PRISMA) was performed. We excluded non-English language articles and abstract-only publications. Due to the large number of RCTs identified, we only include "good quality" RCTs with Jadad score of five. We identified 60 good quality RCTs using CAM as intervention for patients with rheumatic diseases: acupuncture (9), Ayurvedic treatment (3), homeopathic treatment (3), electricity (2), natural products (31), megavitamin therapies (8), chiropractic or osteopathic manipulation (3), and energy healing therapy (1). The studies do not seem to suggest a particular type of CAM is effective for all types for rheumatic diseases. However, some CAM interventions appear to be more effective for certain types of rheumatic diseases. Acupuncture appears to be beneficial for osteoarthritis but not rheumatoid arthritis. For the other therapeutic modalities, the evidence base either contains too few trials or contains trials with contradictory findings which preclude any definitive summary. There were only minor adverse reactions observed for CAM interventions presented. We identified 60 good quality RCTs which were heterogenous in terms of interventions, disease, measures used to assess outcomes, and efficacy of CAM interventions. Evidence indicates that some CAM therapies may be useful for rheumatic diseases, such as acupuncture for osteoarthritis. Further research with larger sample size is required for more conclusive evidence regarding efficacy of CAM interventions. Copyright © 2018 Elsevier Ltd. All rights reserved.
James, Peter B; Bah, Abdulai J
2014-11-08
The widespread use of CAM around the world requires health professionals including pharmacists to have the required knowledge to better advise their patients. This has lead to an increased need for the inclusion of CAM instruction into the mainstream undergraduate Pharmacy education. This study was designed to describe pharmacy students awareness, use, attitude and perceived need for CAM education at COMAHS-USL and at the same time, determine how these descriptive outcomes are influenced by the socio-demographic variables considered in this study. A descriptive cross-sectional survey was conducted among undergraduate pharmacy students (n = 90) at the College of Medicine and Allied Health Sciences, University of Sierra Leone using a structured questionnaire. Chi square, fisher exact test, and general linear model univariate analysis were used to compare data between independent cohorts. All 90 (100%) of the students were aware and have used (except Ayurveda) at least one of the listed CAM modalities. Herbal/Botanical/Supplements followed by Spirituality/Prayer were the most commonly known and used CAM modalities. Almost two thirds of students considered the CAM modalities they have used to be effective and not harmful. Overall, pharmacy students had a positive attitude towards CAM (Mean attitudinal score = 34.9 ± 4. 5 (range 19-43)) with fourth and fifth year students showing a significantly less positive attitude as compared to the first, second and third year (B = -3.203 p = 0.001, 95% confidence interval -5.093 to -1.314). The media [53 (58.9%)] was the most frequent source of information about CAM. Nearly all students [89 (98.9%)] agreed that CAM knowledge is important to them as future pharmacist and that CAM should be included into the Pharmacy curriculum at COMAHS-USL [81 (90.0%)]. Pharmacy students in Sierra Leone are aware of and have used at least one of the CAM modalities and do show a positive attitude towards CAM. This was demonstrated by their overwhelming endorsement for CAM course to be part of the undergraduate pharmacy training at COMAHS-USL. This study among others will inform and guide the development and implementation of CAM instruction at COMAHS-USL.
Experiments evaluating compliance and force feedback effect on manipulator performance
NASA Technical Reports Server (NTRS)
Kugath, D. A.
1972-01-01
The performance capability was assessed of operators performing simulated space tasks using manipulator systems which had compliance and force feedback varied. Two manipulators were used, the E-2 electromechanical man-equivalent (force, reach, etc.) master-slave system and a modified CAM 1400 hydraulic master-slave with 100 lbs force capability at reaches of 24 ft. The CAM 1400 was further modified to operate without its normal force feedback. Several experiments and simulations were performed. The first two involved the E-2 absorbing the energy of a moving mass and secondly, guiding a mass thru a maze. Thus, both work and self paced tasks were studied as servo compliance was varied. Three simulations were run with the E-2 mounted on the CAM 1400 to evaluate the concept of a dexterous manipulator as an end effector of a boom-manipulator. Finally, the CAM 1400 performed a maze test and also simulated the capture of a large mass as the servo compliance was varied and with force feedback included and removed.
von der Heide, Anna Maria; Fallavollita, Pascal; Wang, Lejing; Sandner, Philipp; Navab, Nassir; Weidert, Simon; Euler, Ekkehard
2018-04-01
In orthopaedic trauma surgery, image-guided procedures are mostly based on fluoroscopy. The reduction of radiation exposure is an important goal. The purpose of this work was to investigate the impact of a camera-augmented mobile C-arm (CamC) on radiation exposure and the surgical workflow during a first clinical trial. Applying a workflow-oriented approach, 10 general workflow steps were defined to compare the CamC to traditional C-arms. The surgeries included were arbitrarily identified and assigned to the study. The evaluation criteria were radiation exposure and operation time for each workflow step and the entire surgery. The evaluation protocol was designed and conducted in a single-centre study. The radiation exposure was remarkably reduced by 18 X-ray shots 46% using the CamC while keeping similar surgery times. The intuitiveness of the system, its easy integration into the surgical workflow, and its great potential to reduce radiation have been demonstrated. Copyright © 2017 John Wiley & Sons, Ltd.
Cell adhesion molecules and in vitro fertilization.
Simopoulou, Maria; Nikolopoulou, Elena; Dimakakos, Andreas; Charalabopoulos, Konstantinos; Koutsilieris, Michael
2014-01-01
This review addresses issues regarding the need in the in vitro fertilization (IVF) field for further predictive markers enhancing the standing embryo selection criteria. It aims to serve as a source of defining information for an audience interested in factors related to the wide range of multiple roles played by cell adhesion molecules (CAMs) in several aspects of IVF ultimately associated with the success of an IVF cycle. We begin by stressing the importance of enriching the standing embryo selection criteria available aiming for the golden standard: "extract as much information as possible focusing on non-invasive techniques" so as to guide us towards selecting the embryo with the highest implantation potential. We briefly describe the latest trends on how to best select the right embryo, moving closer towards elective single embryo transfer. These trends are: frozen embryo transfer for all, preimplantation genetic screening, non-invasive selection criteria, and time-lapse imaging. The main part of this review is dedicated to categorizing and presenting published research studies focused on the involvement of CAMs in IVF and its final outcome. Specifically, we discuss the association of CAMs with conditions and complications that arise from performing assisted reproductive techniques, such as ovarian hyperstimulation syndrome, the state of the endometrium, and tubal pregnancies, as well as the levels of CAMs in biological materials available in the IVF laboratory such as follicular fluid, trophectoderm, ovarian granulosa cells, oocytes, and embryos. To conclude, since CAMs have been successfully employed as a diagnostic tool in several pathologies in routine clinical work, we suggest that their multi-faceted nature could serve as a prognostic marker in assisted reproduction, aiming to enrich the list of non-invasive selection and predictive criteria in the IVF setting. We propose that in light of the well-documented involvement of CAMs in the developmental processes of fertilization, embryogenesis, implantation, placentation, and embryonic development, further studies could contribute significantly to achieving a higher quality of treatment and management of infertility. Copyright © 2014 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.
Li, Z; Liu, Y S; Ye, H Q; Liu, Y S; Hu, W J; Zhou, Y S
2017-02-18
To explore a new method of whole-process digital esthetic prosthodontic rehabilitation combined with periodontic surgery for complicated anterior teeth esthetic defects accompanied by soft tissue morphology, to provide an alternative choice for solving this problem under the guidance of three-dimensional (3D) printing digital dental model and surgical guide, thus completing periodontic surgery and digital esthetic rehabilitation of anterior teeth. In this study, 12 patients with complicated esthetic problems accompanied by soft tissue morphology in their anterior teeth were included. The dentition and facial images were obtained by intra-oral scanning and three-dimensional (3D) facial scanning and then calibrated. Two esthetic designs and prosthodontic outcome predictions were created by computer aided design /computer aided manufacturing (CAD/CAM) software combined with digital photography, including consideration of white esthetics and comprehensive consideration of pink-white esthetics. The predictive design of prostheses and the facial appearances of the two designs were evaluated by the patients. If the patients chose the design of comprehensive consideration of pink-white esthetics, they would choose whether they would receive periodontic surgery before esthetic rehabilitation. The dentition design cast of those who chose periodontic surgery would be 3D printed for the guide of periodontic surgery accordingly. In light of the two digital designs based on intra-oral scanning, facing scanning and digital photography, the satisfaction rate of the patients was significantly higher for the comprehensive consideration of pink-white esthetic design (P<0.05) and more patients tended to choose priodontic surgery before esthetic rehabilitation. The 3D printed digital dental model and surgical guide provided significant instructions for periodontic surgery, and achieved success transfer from digital design to clinical application. The prostheses were fabricated by CAD/CAM, thus realizing the whole-process digital esthetic rehabilitation. The new method for esthetic rehabilitation of complicated anterior teeth esthetic defects accompanied by soft tissue morphology, including patient-involved digital esthetic analysis, design, esthetic outcome prediction, 3D printing surgical guide for periodontic surgery and digital fabrication is a practical technology. This method is useful for improvement of clinical communication efficiency between doctor-patient, doctor-technician and doctors from different departments, and is conducive to multidisciplinary treatment of this complicated anterior teeth esthetic problem.
Weeks, Laura C; Strudsholm, Tina
2008-07-19
The use of complementary and alternative medicine (CAM) has become more common in Western developed countries in recent years, as has media reporting on CAM and related issues. Correspondingly, media reports are a primary information source regarding decisions to use CAM. Research on CAM related media reports is becoming increasingly relevant and important; however, identifying key concepts to guide future research is problematic due to the dispersed nature of completed research in this field. A scoping review was conducted to: 1) determine the amount, focus and nature of research on CAM and the mass media; and 2) summarize and disseminate related research results. The main phases were: 1) searching for relevant studies; 2) selecting studies based on pre-defined inclusion criteria; 3) extracting data; and 4) collating, summarizing and reporting the results. Of 4,454 studies identified through various search strategies, 16 were relevant to our objectives and included in a final sample. CAM and media research has focused primarily on print media coverage of a range of CAM therapies, although only a few studies articulated differences within the range of therapies surveyed. Research has been developed through a variety of disciplinary perspectives, with a focus on representation research. The research reviewed suggests that journalists draw on a range of sources to prepare media reports, although most commonly they cite conventional (versus CAM) sources and personal anecdotes. The tone of media reports appears generally positive, which may be related to a lack of reporting on issues related to risk and safety. Finally, a variety of discourses within media representations of CAM are apparent that each appeal to a specific audience through resonance with their specific concerns. Research on CAM and the mass media spans multiple disciplines and strategies of inquiry; however, despite the diversity in approach, it is clear that issues related to production and reception of media content are in need of research attention. To address the varied issues in a comprehensive manner, future research needs to be collaborative, involving researchers across disciplines, journalists and CAM users.
Weeks, Laura C; Strudsholm, Tina
2008-01-01
Background The use of complementary and alternative medicine (CAM) has become more common in Western developed countries in recent years, as has media reporting on CAM and related issues. Correspondingly, media reports are a primary information source regarding decisions to use CAM. Research on CAM related media reports is becoming increasingly relevant and important; however, identifying key concepts to guide future research is problematic due to the dispersed nature of completed research in this field. A scoping review was conducted to: 1) determine the amount, focus and nature of research on CAM and the mass media; and 2) summarize and disseminate related research results. Methods The main phases were: 1) searching for relevant studies; 2) selecting studies based on pre-defined inclusion criteria; 3) extracting data; and 4) collating, summarizing and reporting the results. Results Of 4,454 studies identified through various search strategies, 16 were relevant to our objectives and included in a final sample. CAM and media research has focused primarily on print media coverage of a range of CAM therapies, although only a few studies articulated differences within the range of therapies surveyed. Research has been developed through a variety of disciplinary perspectives, with a focus on representation research. The research reviewed suggests that journalists draw on a range of sources to prepare media reports, although most commonly they cite conventional (versus CAM) sources and personal anecdotes. The tone of media reports appears generally positive, which may be related to a lack of reporting on issues related to risk and safety. Finally, a variety of discourses within media representations of CAM are apparent that each appeal to a specific audience through resonance with their specific concerns. Conclusion Research on CAM and the mass media spans multiple disciplines and strategies of inquiry; however, despite the diversity in approach, it is clear that issues related to production and reception of media content are in need of research attention. To address the varied issues in a comprehensive manner, future research needs to be collaborative, involving researchers across disciplines, journalists and CAM users. PMID:18638413
Ozan, Oguz; Seker, Emre; Kurtulmus-Yilmaz, Sevcan; Ersoy, Ahmet Ersan
2012-10-01
The success of implant-supported restorations depends on the treatment planning and the transfer of planning through the surgical field. Recently, new computer-aided design and manufacturing (CAD/CAM) techniques, such as stereolithographic (SLA) rapid prototyping, have been developed to fabricate surgical guides to improve the precision of implant placement. The objective of the present case is to introduce a recently developed SLA surgical guide system into the rehabilitation of a 62-year-old male patient with mandibular edentulism. After obtaining a cone-beam computerized tomography (CBCT) scan of the mandible with a radiographic template, the images were transferred into a 3-dimensional (3D) image-based software for implant planning. The StentCad Beyond SLA surgical guide system, which is a combination of a currently used surgical template with pilot hollows and a surgical handpiece guidance apparatus, was designed to transfer a preoperatively defined implant position onto the surgical site without any drill-surgical guide contact. For the fabrication of this system, a surgical handpiece was scanned by a laser optical scanner and a mucosa-supported surgical guide was designed according to the patient's 3D model, which was attained from the CBCT images. Four dental implants were inserted through the SLA surgical guide system by a torque-controlled surgical handpiece to the interforaminal region via a flapless surgical procedure. Implants were assessed 3 months after surgery, and an implant-retained mandibular overdenture was fabricated. The present case emphasizes that CAD/CAM SLA surgical guides, along with CBCT images and scanning data, may help clinicians plan and place dental implants.
Noh, Kwantae; Pae, Ahran; Lee, Jung-Woo; Kwon, Yong-Dae
2016-05-01
An obturator prosthesis with insufficient retention and support may be improved with implant placement. However, implant surgery in patients after maxillary tumor resection can be complicated because of limited visibility and anatomic complexity. Therefore, computer-guided surgery can be advantageous even for experienced surgeons. In this clinical report, the use of computer-guided surgery is described for implant placement using a bone-supported surgical template for a patient with maxillary defects. The prosthetic procedure was facilitated and simplified by using computer-aided design/computer-aided manufacture (CAD/CAM) technology. Oral function and phonetics were restored using a tooth- and implant-supported obturator prosthesis. No clinical symptoms and no radiographic signs of significant bone loss around the implants were found at a 3-year follow-up. The treatment approach presented here can be a viable option for patients with insufficient remaining zygomatic bone after a hemimaxillectomy. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Spatial data software integration - Merging CAD/CAM/mapping with GIS and image processing
NASA Technical Reports Server (NTRS)
Logan, Thomas L.; Bryant, Nevin A.
1987-01-01
The integration of CAD/CAM/mapping with image processing using geographic information systems (GISs) as the interface is examined. Particular emphasis is given to the development of software interfaces between JPL's Video Image Communication and Retrieval (VICAR)/Imaged Based Information System (IBIS) raster-based GIS and the CAD/CAM/mapping system. The design and functions of the VICAR and IBIS are described. Vector data capture and editing are studied. Various software programs for interfacing between the VICAR/IBIS and CAD/CAM/mapping are presented and analyzed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harris, Michael D.; Dater, Manasi; Whitaker, Ross
In this study, statistical shape modeling (SSM) was used to quantify three-dimensional (3D) variation and morphologic differences between femurs with and without cam femoroacetabular impingement (FAI). 3D surfaces were generated from CT scans of femurs from 41 controls and 30 cam FAI patients. SSM correspondence particles were optimally positioned on each surface using a gradient descent energy function. Mean shapes for control and patient groups were defined from the resulting particle configurations. Morphological differences between group mean shapes and between the control mean and individual patients were calculated. Principal component analysis was used to describe anatomical variation present in bothmore » groups. The first 6 modes (or principal components) captured statistically significant shape variations, which comprised 84% of cumulative variation among the femurs. Shape variation was greatest in femoral offset, greater trochanter height, and the head-neck junction. The mean cam femur shape protruded above the control mean by a maximum of 3.3 mm with sustained protrusions of 2.5-3.0 mm along the anterolateral head-neck junction and distally along the anterior neck, corresponding well with reported cam lesion locations and soft-tissue damage. This study provides initial evidence that SSM can describe variations in femoral morphology in both controls and cam FAI patients and may be useful for developing new measurements of pathological anatomy. SSM may also be applied to characterize cam FAI severity and provide templates to guide patient-specific surgical resection of bone.« less
A qualitative insight on complementary and alternative medicines used by hypertensive patients.
Ibrahim, Inas Rifaat; Hassali, Mohamed Azmi; Saleem, Fahad; Al Tukmagi, Haydar F
2016-01-01
The self-treatment with complementary and alternative medicines (CAMs) in chronic diseases is portraying an expanding trend worldwide. Yet, little is known concerning patients' motives to use CAM in the control of blood pressure. This study aims to explore the self-use of CAM in the management of hypertension and explore patients' attitudes, perceived benefits, and disclosure to the physician. A qualitative technique was adopted and face-to-face interviews, using a validated interview guide, were carried out among twenty hypertensive patients. A purposive sampling method was used to recruit patients at Al-Karama Teaching Hospital in Baghdad; the capital of Iraq; from January to April 2015. All the interviews were audio-recorded, then transcribed verbatim and examined for thematic relationships. Three major themes were identified through thematic content analysis of the interviews. These encompassed patients' understanding of CAM; experience and perceived benefits; and communication with the doctors. The use of CAM was prevalent among the majority of the respondents. The most commonly used therapies were biological-based practices (herbal remedies, special diet, vitamins, and dietary supplements); traditional therapies (Al-Hijama or cupping); and to a less extent of manipulative body-based therapies (reflexology). Factors influencing the use of CAM were traditions, social relationships, religious beliefs, low-cost therapy, and safety of natural products. The use of CAM was common as a practice of self-treatment among hypertensive patients in Iraq. This was underpinned by the cultural effects, social relationships, religious beliefs, and the perception that natural products are effective and safe. Understanding patients' usage of CAM is of great importance as long as patient's safety and interaction with the standard prescribed treatment are major concerns.
Balneaves, Lynda G; Truant, Tracy L O; Kelly, Mary; Verhoef, Marja J; Davison, B Joyce
2007-08-01
The purpose of this study was to explore the personal and social processes women with breast cancer engaged in when making decisions about complementary and alternative medicine (CAM). The overall aim was to develop a conceptual model of the treatment decision-making process specific to breast cancer care and CAM that will inform future information and decision support strategies. Grounded theory methodology explored the decisions of women with breast cancer using CAM. Semistructured interviews were conducted with 20 women diagnosed with early-stage breast cancer. Following open, axial, and selective coding, the constant comparative method was used to identify key themes in the data and develop a conceptual model of the CAM decision-making process. The final decision-making model, Bridging the Gap, was comprised of four core concepts including maximizing choices/minimizing risks, experiencing conflict, gathering and filtering information, and bridging the gap. Women with breast cancer used one of three decision-making styles to address the paradigmatic, informational, and role conflict they experienced as a result of the gap they perceived between conventional care and CAM: (1) taking it one step at a time, (2) playing it safe, and (3) bringing it all together. Women with breast cancer face conflict and anxiety when making decisions about CAM within a conventional cancer care context. Information and decision support strategies are needed to ensure women are making safe, informed treatment decisions about CAM. The model, Bridging the Gap, provides a conceptual framework for future decision support interventions.
Rutger's CAM2000 chip architecture
NASA Technical Reports Server (NTRS)
Smith, Donald E.; Hall, J. Storrs; Miyake, Keith
1993-01-01
This report describes the architecture and instruction set of the Rutgers CAM2000 memory chip. The CAM2000 combines features of Associative Processing (AP), Content Addressable Memory (CAM), and Dynamic Random Access Memory (DRAM) in a single chip package that is not only DRAM compatible but capable of applying simple massively parallel operations to memory. This document reflects the current status of the CAM2000 architecture and is continually updated to reflect the current state of the architecture and instruction set.
CAD/CAM approach to improving industry productivity gathers momentum
NASA Technical Reports Server (NTRS)
Fulton, R. E.
1982-01-01
Recent results and planning for the NASA/industry Integrated Programs for Aerospace-Vehicle Design (IPAD) program for improving productivity with CAD/CAM methods are outlined. The industrial group work is being mainly done by Boeing, and progress has been made in defining the designer work environment, developing requirements and a preliminary design for a future CAD/CAM system, and developing CAD/CAM technology. The work environment was defined by conducting a detailed study of a reference design process, and key software elements for a CAD/CAM system have been defined, specifically for interactive design or experiment control processes. Further work is proceeding on executive, data management, geometry and graphics, and general utility software, and dynamic aspects of the programs being developed are outlined
Jobes, David A
2012-12-01
The Collaborative Assessment and Management of Suicidality (CAMS) is an evidence-based clinical intervention that has significantly evolved over 25 years of clinical research. CAMS is best understood as a therapeutic framework that emphasizes a unique collaborative assessment and treatment planning process between the suicidal patient and clinician. This process is designed to enhance the therapeutic alliance and increase treatment motivation in the suicidal patient. Central to the CAMS approach is the use of the Suicide Status Form (SSF), which is a multipurpose clinical assessment, treatment planning, tracking, and outcome tool. The original development of CAMS was largely rooted in SSF-based quantitative and qualitative assessment of suicidal risk. As this line of research progressed, CAMS emerged as a problem-focused clinical intervention that is designed to target and treat suicidal "drivers" and ultimately eliminate suicidal coping. To date, CAMS (and the clinical use of the SSF) has been supported by six published correlational studies and one randomized clinical trial (RCT). Currently, two well-powered RCTs are under way, and various new CAMS-related projects are also being pursued. The clinical and empirical evolution of CAMS-how it was developed and what are the next steps for this clinical approach-are described here. © 2012 The American Association of Suicidology.
Use of complementary and alternative medicine in patients with multiple sclerosis in Germany.
Gotta, Mario; Mayer, Christoph A; Huebner, Jutta
2018-02-01
The use of complementary and alternative medicine (CAM) for chronic diseases such as multiple sclerosis (MS) is becoming an increasingly important issue for those affected. Especially in Germany there are only a few studies dealing with CAM, as yet. The aim of this study was to assess the prevalence, the methods used, the subjective benefits as well as physician/patient communication. A structured questionnaire including demographic and disease-specific data, CAM use, perceived benefits as well as physician/patient communication was sent to real and web-based self-help groups for MS in Germany. 343 answers could be evaluated. 77.3% of the participants were females. The mean age was 45.0 ± 11.9 years and the duration of the disease was 12.0 ± 9.6 years. 81.9% said they were using CAM, nearly half (44.8%) used it alternatively to conventional medicine. The average number of CAM- methods used were 3.6. The most popular methods were vitamin supplements, Yoga/Thai chi/Qi Gong, relaxation techniques and meditation. Approximately half (139/49.5%) of CAM users disclosed this to their treating neurologist. Yet, 37,6% have doubts on the competence of the respective physician. Patients with MS have a strong interest in CAM. Usage as alternative therapy is widespread and puts patients at risk of progress of the disease. As patient/physician communication on the topic is increasing, neurologists should be attentive to guiding their patients through safe complementary methods. Copyright © 2017 Elsevier Ltd. All rights reserved.
Pearson, Nancy J; Johnson, Laura Lee; Nahin, Richard L
2006-09-18
Insomnia and other disorders that result in trouble sleeping are common in the United States and are often associated with chronic health conditions. Some individuals with insomnia or trouble sleeping use complementary and alternative medicine (CAM) therapies to treat their condition, but the prevalence of such use and the most common types of CAM therapies selected are not known. Prevalence of insomnia or trouble sleeping and of CAM use for treating such conditions was examined using the 2002 National Health Interview Survey. Logistic regression was used to examine associations between insomnia or trouble sleeping, comorbid conditions, and use of CAM treatments. The 12-month prevalence rate of insomnia or trouble sleeping was 17.4%. There was a strong positive association between adults who reported having insomnia or trouble sleeping and adults who reported 4 of 5 common conditions: obesity (adjusted odds ratio [OR], 1.15; 99% confidence interval [CI], 1.01-1.31), hypertension (OR, 1.32; 99% CI, 1.16-1.51), congestive heart failure (OR, 2.24; 99% CI, 1.60-3.14), and anxiety or depression (OR, 5.64; 99% CI, 5.07-6.29). Of those with insomnia or trouble sleeping, 4.5% used some form of CAM therapy to treat their condition. According to the National Health Interview Survey analysis, over 1.6 million civilian, noninstitutionalized adult US citizens use CAM to treat insomnia or trouble sleeping. The details of this analysis will serve as a guide for future research on CAM therapies for sleep disorders.
CAD/CAM interface design of excimer laser micro-processing system
NASA Astrophysics Data System (ADS)
Jing, Liang; Chen, Tao; Zuo, Tiechuan
2005-12-01
Recently CAD/CAM technology has been gradually used in the field of laser processing. The excimer laser micro-processing system just identified G instruction before CAD/CAM interface was designed. However the course of designing a part with G instruction for users is too hard. The efficiency is low and probability of making errors is high. By secondary development technology of AutoCAD with Visual Basic, an application was developed to pick-up each entity's information in graph and convert them to each entity's processing parameters. Also an additional function was added into former controlling software to identify these processing parameters of each entity and realize continue processing of graphic. Based on the above CAD/CAM interface, Users can design a part in AutoCAD instead of using G instruction. The period of designing a part is sharply shortened. This new way of design greatly guarantees the processing parameters of the part is right and exclusive. The processing of complex novel bio-chip has been realized by this new function.
Review: Lutheran/B-CAM: a laminin receptor on red blood cells and in various tissues.
Kikkawa, Yamato; Miner, Jeffrey H
2005-01-01
The Lutheran blood group glycoprotein (Lu), also known as basal cell adhesion molecule (B-CAM), is a transmembrane receptor with five immunoglobulin-like domains in its extracellular region; it is therefore classified as a member of the immunoglobulin (Ig) gene family. Lu/B-CAM is observed not only on red blood cells, but also on a subset of muscle and epithelial cells in various tissues. Recently, several groups have reported that Lu/B-CAM is a novel receptor for laminin a5. The laminin a5 chain is a component of the laminin-511 (alpha 5 beta 1 gamma 1), -521 (alpha 5 beta 2 gamma 1), and -523 (alpha 5 beta 2 gamma 3) heterotrimers and is expressed throughout the mammalian body. We also have shown that Lu/B-CAM is co-localized with laminin alpha 5 in various tissues. Although the biological role of Lu/B-CAM remains unclear, the specific binding of Lu/B-CAM to laminin alpha 5 suggests that it plays an important role in developmental and physiological processes. It also is necessary to investigate further the interaction between Lu/B-CAM and laminin a5 in pathological processes, including sickle cell disease and cancer.
Loree, Amy M; Ondersma, Steven J; Grekin, Emily R
2017-05-01
Although effective treatments exist, most women who smoke during pregnancy neither seek nor receive treatment. Complementary and alternative medicine (CAM) treatments (eg, mindfulness, yoga, and acupuncture) may be attractive, low-cost options that can be used to assist a large proportion of pregnant women with smoking cessation. This study examined participant characteristics and treatment utilization among pregnant smokers in the National Survey on Drug Use and Health (NSDUH) and the National Health Interview Survey (NHIS) in order to explore the prevalence and predictors of CAM use for any purpose within this population. Results indicated that a considerable proportion (6.9%-29.1%) of pregnant smokers are already accessing CAM, particularly Whites and those of greater socioeconomic status. Use of yoga, meditation, and massage increased across study waves. NSDUH participants were most likely to report seeking chiropractic or massage therapy; NHIS participants most frequently reported use of herbs/supplements, deep breathing, and meditation. Up to roughly a quarter of women endorsed traditional/conventional and CAM treatment use, suggesting that some pregnant smokers are open to trying a variety of approaches to promote health. Further research is needed to validate CAM treatments for smoking cessation and to guide safety and treatment recommendations during pregnancy. CAM treatments may be an attractive treatment alternative for pregnant smokers. However, no previous investigations have examined whether pregnant smokers seek out these treatments. Using nationally representative survey data, the present study aimed to explore whether pregnant smokers use CAM treatments. We found that approximately 7%-29% of pregnant smokers reported using a variety of CAM methods, suggesting the need for further investigation into the efficacy and dissemination of CAM for smoking in pregnancy. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.
Complementary and Alternative Medicine (CAM) use by Malaysian oncology patients.
Farooqui, Maryam; Hassali, Mohamed Azmi; Abdul Shatar, Aishah Knight; Shafie, Asrul Akmal; Seang, Tan Boon; Farooqui, Muhammad Aslam
2012-05-01
The current study sought to evaluate Malaysian oncology patients' decision making about the use of Complementary and Alternative Medicine (CAM) for the management of their care. Patients were interviewed across three major Malaysian ethnic groups, Malay, Chinese and Indian. Thematic content analysis identified four central themes: Conceptualizing CAM, the decision making process; rationale given for selecting or rejecting CAM and barriers to CAM use. Participants generally used the term 'traditional medicine', referred to locally as 'ubat kampung', meaning medicine derived from 'local traditions'. Mixed reactions were shown concerning the effectiveness of CAM to cure cancer and the slow progression of CAM results and treatment costs were cited as major barriers to CAM use. Concerns regarding safety and efficacy of CAM in ameliorating cancer as well as potential interactions with conventional therapies highlighted the importance of patients' knowledge about cancer treatments. Copyright © 2011 Elsevier Ltd. All rights reserved.
Lu, Li; Liu, Shusheng; Shi, Shenggen; Yang, Jianzhong
2011-10-01
China-made 5-axis simultaneous contouring CNC machine tool and domestically developed industrial computer-aided manufacture (CAM) technology were used for full crown fabrication and measurement of crown accuracy, with an attempt to establish an open CAM system for dental processing and to promote the introduction of domestic dental computer-aided design (CAD)/CAM system. Commercially available scanning equipment was used to make a basic digital tooth model after preparation of crown, and CAD software that comes with the scanning device was employed to design the crown by using domestic industrial CAM software to process the crown data in order to generate a solid model for machining purpose, and then China-made 5-axis simultaneous contouring CNC machine tool was used to complete machining of the whole crown and the internal accuracy of the crown internal was measured by using 3D-MicroCT. The results showed that China-made 5-axis simultaneous contouring CNC machine tool in combination with domestic industrial CAM technology can be used for crown making and the crown was well positioned in die. The internal accuracy was successfully measured by using 3D-MicroCT. It is concluded that an open CAM system for dentistry on the basis of China-made 5-axis simultaneous contouring CNC machine tool and domestic industrial CAM software has been established, and development of the system will promote the introduction of domestically-produced dental CAD/CAM system.
In Vitro Analysis of the Fracture Resistance of CAD/CAM Denture Base Resins.
Steinmassl, Otto; Offermanns, Vincent; Stöckl, Wolfgang; Dumfahrt, Herbert; Grunert, Ingrid; Steinmassl, Patricia-Anca
2018-03-08
Computer-aided design and computer-aided manufacturing (CAD/CAM) denture base manufacturers claim to produce their resin pucks under high heat and pressure. Therefore, CAD/CAM dentures are assumed to have enhanced mechanical properties and, as a result, are often produced with lower denture base thicknesses than conventional, manually fabricated dentures. The aim of this study was to investigate if commercially available CAD/CAM denture base resins have more favourable mechanical properties than conventionally processed denture base resins. For this purpose, a series of three-point bending tests conforming to ISO specifications were performed on a total of 80 standardised, rectangular CAD/CAM denture base resin specimens from five different manufacturers (AvaDent, Baltic Denture System, Vita VIONIC, Whole You Nexteeth, and Wieland Digital Dentures). A heat-polymerising resin and an autopolymerising resin served as the control groups. The breaking load, fracture toughness, and the elastic modulus were assessed. Additionally, the fracture surface roughness and texture were investigated. Only one CAD/CAM resin showed a significantly increased breaking load. Two CAD/CAM resins had a significantly higher fracture toughness than the control groups, and all CAD/CAM resins had higher elastic moduli than the controls. Our results indicate that CAD/CAM denture base resins do not generally have better mechanical properties than manually processed resins. Therefore, the lower minimum denture base thicknesses should be regarded with some caution.
In Vitro Analysis of the Fracture Resistance of CAD/CAM Denture Base Resins
Stöckl, Wolfgang; Dumfahrt, Herbert; Grunert, Ingrid
2018-01-01
Computer-aided design and computer-aided manufacturing (CAD/CAM) denture base manufacturers claim to produce their resin pucks under high heat and pressure. Therefore, CAD/CAM dentures are assumed to have enhanced mechanical properties and, as a result, are often produced with lower denture base thicknesses than conventional, manually fabricated dentures. The aim of this study was to investigate if commercially available CAD/CAM denture base resins have more favourable mechanical properties than conventionally processed denture base resins. For this purpose, a series of three-point bending tests conforming to ISO specifications were performed on a total of 80 standardised, rectangular CAD/CAM denture base resin specimens from five different manufacturers (AvaDent, Baltic Denture System, Vita VIONIC, Whole You Nexteeth, and Wieland Digital Dentures). A heat-polymerising resin and an autopolymerising resin served as the control groups. The breaking load, fracture toughness, and the elastic modulus were assessed. Additionally, the fracture surface roughness and texture were investigated. Only one CAD/CAM resin showed a significantly increased breaking load. Two CAD/CAM resins had a significantly higher fracture toughness than the control groups, and all CAD/CAM resins had higher elastic moduli than the controls. Our results indicate that CAD/CAM denture base resins do not generally have better mechanical properties than manually processed resins. Therefore, the lower minimum denture base thicknesses should be regarded with some caution. PMID:29518022
NASA Astrophysics Data System (ADS)
Dequaire, T.; Meslin, P. Y.; Rapin, W.; Jaber, M.; Maurice, S.; Gasnault, O.; Forni, O.; Coll, P.; Szopa, C.
2015-10-01
Since 2012, he Curiosity rover on Mars seeks clues of habitability in Gale crater. One of these clues is the presence of organic matter. For the moment,only a few traces of organic matter was recently found with the SAM experiment. We propose here to evaluate the capabilities for the ChemCam experiment to detect organic molecules from its elemental analysis of the Mars regolith or rocks. The first results obtained in laboratory with the ChemCam spare model and different samples show that it is possible to detect organic signatures with LIBS,focusing on atomic carbon, hydrogen and nitrogen peaks,and on a C-N molecular peak when the samples areenriched in organic molecules(100-10 wt%). We currently work with Mars representative samples to determine the instrument detection limitfor organics, in order to determine if it can be used to guide Curiosity towards interesting outcrops.
Is complementary and alternative medicine (CAM) cost-effective? a systematic review
Herman, Patricia M; Craig, Benjamin M; Caspi, Opher
2005-01-01
Background Out-of-pocket expenditures of over $34 billion per year in the US are an apparent testament to a widely held belief that complementary and alternative medicine (CAM) therapies have benefits that outweigh their costs. However, regardless of public opinion, there is often little more than anecdotal evidence on the health and economic implications of CAM therapies. The objectives of this study are to present an overview of economic evaluation and to expand upon a previous review to examine the current scope and quality of CAM economic evaluations. Methods The data sources used were Medline, AMED, Alt-HealthWatch, and the Complementary and Alternative Medicine Citation Index; January 1999 to October 2004. Papers that reported original data on specific CAM therapies from any form of standard economic analysis were included. Full economic evaluations were subjected to two types of quality review. The first was a 35-item checklist for reporting quality, and the second was a set of four criteria for study quality (randomization, prospective collection of economic data, comparison to usual care, and no blinding). Results A total of 56 economic evaluations (39 full evaluations) of CAM were found covering a range of therapies applied to a variety of conditions. The reporting quality of the full evaluations was poor for certain items, but was comparable to the quality found by systematic reviews of economic evaluations in conventional medicine. Regarding study quality, 14 (36%) studies were found to meet all four criteria. These exemplary studies indicate CAM therapies that may be considered cost-effective compared to usual care for various conditions: acupuncture for migraine, manual therapy for neck pain, spa therapy for Parkinson's, self-administered stress management for cancer patients undergoing chemotherapy, pre- and post-operative oral nutritional supplementation for lower gastrointestinal tract surgery, biofeedback for patients with "functional" disorders (eg, irritable bowel syndrome), and guided imagery, relaxation therapy, and potassium-rich diet for cardiac patients. Conclusion Whereas the number and quality of economic evaluations of CAM have increased in recent years and more CAM therapies have been shown to be of good value, the majority of CAM therapies still remain to be evaluated. PMID:15932647
CamBAfx: Workflow Design, Implementation and Application for Neuroimaging
Ooi, Cinly; Bullmore, Edward T.; Wink, Alle-Meije; Sendur, Levent; Barnes, Anna; Achard, Sophie; Aspden, John; Abbott, Sanja; Yue, Shigang; Kitzbichler, Manfred; Meunier, David; Maxim, Voichita; Salvador, Raymond; Henty, Julian; Tait, Roger; Subramaniam, Naresh; Suckling, John
2009-01-01
CamBAfx is a workflow application designed for both researchers who use workflows to process data (consumers) and those who design them (designers). It provides a front-end (user interface) optimized for data processing designed in a way familiar to consumers. The back-end uses a pipeline model to represent workflows since this is a common and useful metaphor used by designers and is easy to manipulate compared to other representations like programming scripts. As an Eclipse Rich Client Platform application, CamBAfx's pipelines and functions can be bundled with the software or downloaded post-installation. The user interface contains all the workflow facilities expected by consumers. Using the Eclipse Extension Mechanism designers are encouraged to customize CamBAfx for their own pipelines. CamBAfx wraps a workflow facility around neuroinformatics software without modification. CamBAfx's design, licensing and Eclipse Branding Mechanism allow it to be used as the user interface for other software, facilitating exchange of innovative computational tools between originating labs. PMID:19826470
Wong, M S; Cheng, J C Y; Wong, M W; So, S F
2005-04-01
A study was conducted to compare the CAD/CAM method with the conventional manual method in fabrication of spinal orthoses for patients with adolescent idiopathic scoliosis. Ten subjects were recruited for this study. Efficiency analyses of the two methods were performed from cast filling/ digitization process to completion of cast/image rectification. The dimensional changes of the casts/ models rectified by the two cast rectification methods were also investigated. The results demonstrated that the CAD/CAM method was faster than the conventional manual method in the studied processes. The mean rectification time of the CAD/CAM method was shorter than that of the conventional manual method by 108.3 min (63.5%). This indicated that the CAD/CAM method took about 1/3 of the time of the conventional manual to finish cast rectification. In the comparison of cast/image dimensional differences between the conventional manual method and the CAD/CAM method, five major dimensions in each of the five rectified regions namely the axilla, thoracic, lumbar, abdominal and pelvic regions were involved. There were no significant dimensional differences (p < 0.05) in 19 out of the 25 studied dimensions. This study demonstrated that the CAD/CAM system could save the time in the rectification process and offer a relatively high resemblance in cast rectification as compared with the conventional manual method.
Distributed Energy Resources Customer Adoption Model - Graphical User Interface, Version 2.1.8
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ewald, Friedrich; Stadler, Michael; Cardoso, Goncalo F
The DER-CAM Graphical User Interface has been redesigned to consist of a dynamic tree structure on the left side of the application window to allow users to quickly navigate between different data categories and views. Views can either be tables with model parameters and input data, the optimization results, or a graphical interface to draw circuit topology and visualize investment results. The model parameters and input data consist of tables where values are assigned to specific keys. The aggregation of all model parameters and input data amounts to the data required to build a DER-CAM model, and is passed tomore » the GAMS solver when users initiate the DER-CAM optimization process. Passing data to the GAMS solver relies on the use of a Java server that handles DER-CAM requests, queuing, and results delivery. This component of the DER-CAM GUI can be deployed either locally or remotely, and constitutes an intermediate step between the user data input and manipulation, and the execution of a DER-CAM optimization in the GAMS engine. The results view shows the results of the DER-CAM optimization and distinguishes between a single and a multi-objective process. The single optimization runs the DER-CAM optimization once and presents the results as a combination of summary charts and hourly dispatch profiles. The multi-objective optimization process consists of a sequence of runs initiated by the GUI, including: 1) CO2 minimization, 2) cost minimization, 3) a user defined number of points in-between objectives 1) and 2). The multi-objective results view includes both access to the detailed results of each point generated by the process as well as the generation of a Pareto Frontier graph to illustrate the trade-off between objectives. DER-CAM GUI 2.1.8 also introduces the ability to graphically generate circuit topologies, enabling support to DER-CAM 5.0.0. This feature consists of: 1) The drawing area, where users can manually create nodes and define their properties (e.g. point of common coupling, slack bus, load) and connect them through edges representing either power lines, transformers, or heat pipes, all with user defined characteristics (e.g., length, ampacity, inductance, or heat loss); 2) The tables, which display the user-defined topology in the final numerical form that will be passed to the DER-CAM optimization. Finally, the DER-CAM GUI is also deployed with a database schema that allows users to provide different energy load profiles, solar irradiance profiles, and tariff data, that can be stored locally and later used in any DER-CAM model. However, no real data will be delivered with this version.« less
Schiffke, Heather; Fleishman, Susan; Haas, Mitch; Cruser, des Anges; LeFebvre, Ron; Sullivan, Barbara; Taylor, Barry; Gaster, Barak
2014-01-01
Abstract Background: As evidence-based medicine (EBM) becomes a standard in health care, it is essential that practitioners of complementary and alternative medicine (CAM) become experts in searching and evaluating the research literature. In support of this goal, the National Institutes of Health (NIH) National Center for Complementary and Alternative Medicine (NCCAM) provided R25 funding to nine CAM colleges to develop individual programs focused on teaching EBM. An overarching goal of these research education grants has been to provide CAM faculty and students with the skills they need to apply a rigorous evidence-based perspective to their training and practice. Methods/Results: This paper reviews the competencies and teaching strategies developed and implemented to enhance research literacy at all nine R25-funded institutions. While each institution designed approaches suitable for its research culture, the guiding principles were similar: to develop evidence-informed skills and knowledge, thereby helping students and faculty to critically appraise evidence and then use that evidence to guide their clinical practice. Curriculum development and assessment included faculty-driven learning activities and longitudinal curricular initiatives to encourage skill reinforcement and evaluate progress. Conclusion: As the field of integrative medicine matures, the NIH-NCCAM research education grants provide essential training for future clinicians and clinician-researchers. Building this workforce will facilitate multidisciplinary collaborations that address the unique needs for research that informs integrative clinical practice. PMID:25380144
Content addressable memory project
NASA Technical Reports Server (NTRS)
Hall, Josh; Levy, Saul; Smith, D.; Wei, S.; Miyake, K.; Murdocca, M.
1991-01-01
The progress on the Rutgers CAM (Content Addressable Memory) Project is described. The overall design of the system is completed at the architectural level and described. The machine is composed of two kinds of cells: (1) the CAM cells which include both memory and processor, and support local processing within each cell; and (2) the tree cells, which have smaller instruction set, and provide global processing over the CAM cells. A parameterized design of the basic CAM cell is completed. Progress was made on the final specification of the CPS. The machine architecture was driven by the design of algorithms whose requirements are reflected in the resulted instruction set(s). A few of these algorithms are described.
Endodontic applications of 3D printing.
Anderson, J; Wealleans, J; Ray, J
2018-02-27
Computer-aided design (CAD) and computer-aided manufacturing (CAM) technologies can leverage cone beam computed tomography data for production of objects used in surgical and nonsurgical endodontics and in educational settings. The aim of this article was to review all current applications of 3D printing in endodontics and to speculate upon future directions for research and clinical use within the specialty. A literature search of PubMed, Ovid and Scopus was conducted using the following terms: stereolithography, 3D printing, computer aided rapid prototyping, surgical guide, guided endodontic surgery, guided endodontic access, additive manufacturing, rapid prototyping, autotransplantation rapid prototyping, CAD, CAM. Inclusion criteria were articles in the English language documenting endodontic applications of 3D printing. Fifty-one articles met inclusion criteria and were utilized. The endodontic literature on 3D printing is generally limited to case reports and pre-clinical studies. Documented solutions to endodontic challenges include: guided access with pulp canal obliteration, applications in autotransplantation, pre-surgical planning and educational modelling and accurate location of osteotomy perforation sites. Acquisition of technical expertise and equipment within endodontic practices present formidable obstacles to widespread deployment within the endodontic specialty. As knowledge advances, endodontic postgraduate programmes should consider implementing 3D printing into their curriculums. Future research directions should include clinical outcomes assessments of treatments employing 3D printed objects. Published 2018. This article is a U.S. Government work and is in the public domain in the USA.
Isolation and characterization of a novel calmodulin-binding protein from potato
NASA Technical Reports Server (NTRS)
Reddy, Anireddy S N.; Day, Irene S.; Narasimhulu, S. B.; Safadi, Farida; Reddy, Vaka S.; Golovkin, Maxim; Harnly, Melissa J.
2002-01-01
Tuberization in potato is controlled by hormonal and environmental signals. Ca(2+), an important intracellular messenger, and calmodulin (CaM), one of the primary Ca(2+) sensors, have been implicated in controlling diverse cellular processes in plants including tuberization. The regulation of cellular processes by CaM involves its interaction with other proteins. To understand the role of Ca(2+)/CaM in tuberization, we have screened an expression library prepared from developing tubers with biotinylated CaM. This screening resulted in isolation of a cDNA encoding a novel CaM-binding protein (potato calmodulin-binding protein (PCBP)). Ca(2+)-dependent binding of the cDNA-encoded protein to CaM is confirmed by (35)S-labeled CaM. The full-length cDNA is 5 kb long and encodes a protein of 1309 amino acids. The deduced amino acid sequence showed significant similarity with a hypothetical protein from another plant, Arabidopsis. However, no homologs of PCBP are found in nonplant systems, suggesting that it is likely to be specific to plants. Using truncated versions of the protein and a synthetic peptide in CaM binding assays we mapped the CaM-binding region to a 20-amino acid stretch (residues 1216-1237). The bacterially expressed protein containing the CaM-binding domain interacted with three CaM isoforms (CaM2, CaM4, and CaM6). PCBP is encoded by a single gene and is expressed differentially in the tissues tested. The expression of CaM, PCBP, and another CaM-binding protein is similar in different tissues and organs. The predicted protein contained seven putative nuclear localization signals and several strong PEST motifs. Fusion of the N-terminal region of the protein containing six of the seven nuclear localization signals to the reporter gene beta-glucuronidase targeted the reporter gene to the nucleus, suggesting a nuclear role for PCBP.
Yin, Jiayue; Liu, Dan; Huang, Yuehua; Wu, Lin; Tang, Xiaolin
2017-11-01
"Pink esthetics," which are considered to be as important as "white esthetics," have attracted increasing attention. To date, clinicians rarely have applied computer-aided design and computer-aided manufacturing (CAD/CAM) techniques in the rebuilding of the contour of the marginal gingiva in the esthetic zone. In this case report, the authors describe a female patient who had gingival inflammation and an asymmetrical contour of the marginal gingiva of the anterior maxillary teeth because previously placed ceramic crowns violated the biological width. The authors used a 3-dimensional-printing surgery template to guide precise crown-lengthening surgery to expose subgingival shoulders and to obtain an ideal marginal gingival contour. Then the authors used interim CAD/CAM crowns to induce the growth of the interdental papilla by 0.5 to 1.5 millimeters. Finally, the patient had a symmetrical and well-balanced contour of the marginal gingiva. In addition, the authors reduced the patient's "black triangle" areas to the greatest possible extent. This case report illustrates that CAD/CAM products, including 3-dimensional-printing surgery templates and CAD/CAM interim crowns, are helpful in shaping and rebuilding the ideal contour of the marginal gingiva in the esthetic zone, such as the anterior maxillary teeth. Copyright © 2017 American Dental Association. Published by Elsevier Inc. All rights reserved.
Setting research priorities by applying the combined approach matrix.
Ghaffar, Abdul
2009-04-01
Priority setting in health research is a dynamic process. Different organizations and institutes have been working in the field of research priority setting for many years. In 1999 the Global Forum for Health Research presented a research priority setting tool called the Combined Approach Matrix or CAM. Since its development, the CAM has been successfully applied to set research priorities for diseases, conditions and programmes at global, regional and national levels. This paper briefly explains the CAM methodology and how it could be applied in different settings, giving examples and describing challenges encountered in the process of setting research priorities and providing recommendations for further work in this field. The construct and design of the CAM is explained along with different steps needed, including planning and organization of a priority-setting exercise and how it could be applied in different settings. The application of the CAM are described by using three examples. The first concerns setting research priorities for a global programme, the second describes application at the country level and the third setting research priorities for diseases. Effective application of the CAM in different and diverse environments proves its utility as a tool for setting research priorities. Potential challenges encountered in the process of research priority setting are discussed and some recommendations for further work in this field are provided.
Long, Andrew F
2009-06-18
The potential contribution of complementary and alternative medicine (CAM) modalities to promote and support critical health literacy has not received substantial attention within either the health promotion or the CAM literature. This paper explores the potential of one CAM modality, shiatsu, in promoting well-being and critical health literacy. Data are drawn from a longitudinal, 6 months observational, pragmatic study of the effects and experience of shiatsu within three European countries (Austria, Spain and the UK). Client postal questionnaires included: advice received, changes made 6 months later, clients 'hopes' from having shiatsu and features of the client-practitioner relationship. At baseline, three-quarters of clients (n = 633) received advice, on exercise, diet, posture, points to work on at home or other ways of self-care. At 6 months follow-up, about four-fifths reported making changes to their lifestyle 'as a result of having shiatsu treatment', including taking more rest and relaxation or exercise, changing their diet, reducing time at work and other changes such as increased body/mind awareness and levels of confidence and resolve. Building on the findings, an explanatory model of possible ways that a CAM therapy could contribute to health promotion is presented to guide future research, both within and beyond CAM. Supporting individuals to take control of their self-care requires advice-giving within a supportive treatment context and practitioner relationship, with clients who are open to change and committed to maintaining their health. CAM modalities may have an important role to play in this endeavour.
Ciocca, Leonardo; Donati, Davide; Fantini, Massimiliano; Landi, Elena; Piattelli, Adriano; Iezzi, Giovanna; Tampieri, Anna; Spadari, Alessandro; Romagnoli, Noemi; Scotti, Roberto
2013-08-01
In this study, rapid CAD-CAM prototyping of pure hydroxyapatite to replace temporomandibular joint condyles was tested in sheep. Three adult animals were implanted with CAD-CAM-designed porous hydroxyapatite scaffolds as condyle substitutes. The desired scaffold shape was achieved by subtractive automated milling machining (block reduction). Custom-made surgical guides were created by direct metal laser sintering and were used to export the virtual planning of the bone cut lines into the surgical environment. Using the same technique, fixation plates were created and applied to the scaffold pre-operatively to firmly secure the condyles to the bone and to assure primary stability of the hydroxyapatite scaffolds during masticatory function. Four months post-surgery, the sheep were sacrificed. The hydroxyapatite scaffolds were explanted, and histological specimens were prepared. Different histological tissues penetrating the scaffold macropores, the sequence of bone remodeling, new apposition of bone and/or cartilage as a consequence of the different functional anatomic role, and osseointegration at the interface between the scaffold and bone were documented. This animal model was found to be appropriate for testing CAD-CAM customization and the biomechanical properties of porous, pure hydroxyapatite scaffolds used as joint prostheses.
Ablin, Jacob; Fitzcharles, Mary-Ann; Buskila, Dan; Shir, Yoram; Sommer, Claudia; Häuser, Winfried
2013-01-01
Objective. Current evidence indicates that there is no single ideal treatment for fibromyalgia syndrome (FMS). First choice treatment options remain debatable, especially concerning the importance of complementary and alternative medicine (CAM) treatments. Methods. Three evidence-based interdisciplinary guidelines on FMS in Canada, Germany, and Israel were compared for their first choice and CAM-recommendations. Results. All three guidelines emphasized a patient-tailored approach according to the key symptoms. Aerobic exercise, cognitive behavioral therapy, and multicomponent therapy were first choice treatments. The guidelines differed in the grade of recommendation for drug treatment. Anticonvulsants (gabapentin, pregabalin) and serotonin noradrenaline reuptake inhibitors (duloxetine, milnacipran) were strongly recommended by the Canadian and the Israeli guidelines. These drugs received only a weak recommendation by the German guideline. In consideration of CAM-treatments, acupuncture, hypnosis/guided imagery, and Tai Chi were recommended by the German and Israeli guidelines. The Canadian guidelines did not recommend any CAM therapy. Discussion. Recent evidence-based interdisciplinary guidelines concur on the importance of treatment tailored to the individual patient and further emphasize the need of self-management strategies (exercise, and psychological techniques).
EpCAM and the biology of hepatic stem/progenitor cells
Theise, Neil D.; Schmelzer, Eva; Boulter, Luke; Gires, Olivier; van Grunsven, Leo A.
2014-01-01
Epithelial cell adhesion molecule (EpCAM) is a transmembrane glycoprotein, which is frequently and highly expressed on carcinomas, tumor-initiating cells, selected tissue progenitors, and embryonic and adult stem cells. During liver development, EpCAM demonstrates a dynamic expression, since it can be detected in fetal liver, including cells of the parenchyma, whereas mature hepatocytes are devoid of EpCAM. Liver regeneration is associated with a population of EpCAM-positive cells within ductular reactions, which gradually lose the expression of EpCAM along with maturation into hepatocytes. EpCAM can be switched on and off through a wide panel of strategies to fine-tune EpCAM-dependent functional and differentiative traits. EpCAM-associated functions relate to cell–cell adhesion, proliferation, maintenance of a pluripotent state, regulation of differentiation, migration, and invasion. These functions can be conferred by the full-length protein and/or EpCAM-derived fragments, which are generated upon regulated intramembrane proteolysis. Control by EpCAM therefore not only depends on the presence of full-length EpCAM at cellular membranes but also on varying rates of the formation of EpCAM-derived fragments that have their own regulatory properties and on changes in the association of EpCAM with interaction partners. Thus spatiotemporal localization of EpCAM in immature liver progenitors, transit-amplifying cells, and mature liver cells will decisively impact the regulation of EpCAM functions and might be one of the triggers that contributes to the adaptive processes in stem/progenitor cell lineages. This review will summarize EpCAM-related molecular events and how they relate to hepatobiliary differentiation and regeneration. PMID:25477371
Positioning and locking apparatus
Hayward, Milton L.; Harper, William H.
1987-01-01
A positioning and locking apparatus including a fixture having a rotatable torque ring provided with a plurality of cam segments for automatically guiding a container into a desired location within the fixture. Rotation of the ring turns the container into a final position in pressure sealing relation against a hatch member.
Positioning and locking apparatus
Hayward, M.L.; Harper, W.H.
1985-06-19
A positioning and locking apparatus including a fixture having a rotatable torque ring provided with a plurality of cam segments for automatically guiding a container into a desired location within the fixture. Rotation of the ring turns the container into a final position in pressure sealing relation against a hatch member.
Mohanta, Tapan Kumar; Kumar, Pradeep; Bae, Hanhong
2017-02-03
Ca 2+ ion is a versatile second messenger that operate in a wide ranges of cellular processes that impact nearly every aspect of life. Ca 2+ regulates gene expression and biotic and abiotic stress responses in organisms ranging from unicellular algae to multi-cellular higher plants through the cascades of calcium signaling processes. In this study, we deciphered the genomics and evolutionary aspects of calcium signaling event of calmodulin (CaM) and calmodulin like- (CML) proteins. We studied the CaM and CML gene family of 41 different species across the plant lineages. Genomic analysis showed that plant encodes more calmodulin like-protein than calmodulins. Further analyses showed, the majority of CMLs were intronless, while CaMs were intron rich. Multiple sequence alignment showed, the EF-hand domain of CaM contains four conserved D-x-D motifs, one in each EF-hand while CMLs contain only one D-x-D-x-D motif in the fourth EF-hand. Phylogenetic analysis revealed that, the CMLs were evolved earlier than CaM and later diversified. Gene expression analysis demonstrated that different CaM and CMLs genes were express differentially in different tissues in a spatio-temporal manner. In this study we provided in detailed genome-wide identifications and characterization of CaM and CML protein family, phylogenetic relationships, and domain structure. Expression study of CaM and CML genes were conducted in Glycine max and Phaseolus vulgaris. Our study provides a strong foundation for future functional research in CaM and CML gene family in plant kingdom.
Esch, Tobias; Guarna, Massimo; Bianchi, Enrica; Zhu, Wei; Stefano, George B
2004-06-01
Currently, complementary and alternative medicine (CAM) are experiencing growing popularity, especially in former industrialized countries. However, most of the underlying physiological and molecular mechanisms as well as participating biological structures are still speculative. Specific and non-specific effects may play a role in CAM. Moreover, trust, belief, and expectation may be of importance, pointing towards common central nervous system (CNS) pathways involved in CAM. Four CAM approaches (acupuncture, meditation, music therapy, and massage therapy) were examined with regard to the CNS activity pattern involved. CNS commonalities between different approaches were investigated. Frontal/prefrontal and limbic brain structures play a role in CAM. Particularly, left-anterior regions of the brain and reward or motivation circuitry constituents are involved, indicating positive affect and emotion-related memory processing--accompanied by endocrinologic and autonomic functions--as crucial components of CAM effects. Thus, trust and belief in a therapist or positive therapy expectations seem to be important. However, besides common non-specific or subjective effects, specific (objective) physiological components also exist. Non-specific CNS commonalities are involved in various CAM therapies. Different therapeutic approaches physiologically overlap in the brain. However, molecular correspondents of the detected CNS analogies still have to be specified. In particular, fast acting autoregulatory signaling molecules presumably play a role. These may also be involved in the placebo response.
Xi-cam: a versatile interface for data visualization and analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pandolfi, Ronald J.; Allan, Daniel B.; Arenholz, Elke
Xi-cam is an extensible platform for data management, analysis and visualization.Xi-camaims to provide a flexible and extensible approach to synchrotron data treatment as a solution to rising demands for high-volume/high-throughput processing pipelines. The core ofXi-camis an extensible plugin-based graphical user interface platform which provides users with an interactive interface to processing algorithms. Plugins are available for SAXS/WAXS/GISAXS/GIWAXS, tomography and NEXAFS data. WithXi-cam's `advanced' mode, data processing steps are designed as a graph-based workflow, which can be executed live, locally or remotely. Remote execution utilizes high-performance computing or de-localized resources, allowing for the effective reduction of high-throughput data.Xi-cam's plugin-based architecture targetsmore » cross-facility and cross-technique collaborative development, in support of multi-modal analysis.Xi-camis open-source and cross-platform, and available for download on GitHub.« less
Xi-cam: a versatile interface for data visualization and analysis
Pandolfi, Ronald J.; Allan, Daniel B.; Arenholz, Elke; ...
2018-05-31
Xi-cam is an extensible platform for data management, analysis and visualization.Xi-camaims to provide a flexible and extensible approach to synchrotron data treatment as a solution to rising demands for high-volume/high-throughput processing pipelines. The core ofXi-camis an extensible plugin-based graphical user interface platform which provides users with an interactive interface to processing algorithms. Plugins are available for SAXS/WAXS/GISAXS/GIWAXS, tomography and NEXAFS data. WithXi-cam's `advanced' mode, data processing steps are designed as a graph-based workflow, which can be executed live, locally or remotely. Remote execution utilizes high-performance computing or de-localized resources, allowing for the effective reduction of high-throughput data.Xi-cam's plugin-based architecture targetsmore » cross-facility and cross-technique collaborative development, in support of multi-modal analysis.Xi-camis open-source and cross-platform, and available for download on GitHub.« less
Cassetta, M; Giansanti, M
2016-07-01
A reduction in orthodontic treatment time can be attained using corticotomies. The aggressive nature of corticotomy due to the elevation of muco-periosteal flaps and to the duration of the surgery raised reluctance for its employ among patients and dental community. This study aims to provide detailed information on the design and manufacture of a 3D-printed CAD-CAM (computer-aided design and computer-aided manufacturing) surgical guide which can aid the clinician in achieving a minimally-invasive, flapless corticotomy. An impression of dental arches was created; the models were digitally-acquired using a 3D scanner and saved as STereoLithography ( STL ) files. The patient underwent cone beam computed tomography (CBCT): images of jaws and teeth were transformed into 3D models and saved as an STL file. An acrylic template with the design of a surgical guide was manufactured and scanned. The STLs of jaws, scanned casts, and acrylic templates were matched. 3D modeling software allowed the view of the 3D models from different perspectives and planes with perfect rendering. The 3D model of the acrylic template was transformed into a surgical guide with slots designed to guide, at first, a scalpel blade and then a piezoelectric cutting insert. The 3D STL model of the surgical guide was printed. This procedure allowed the manufacturing of a 3D-printed CAD/CAM surgical guide, which overcomes the disadvantages of the corticotomy, removing the need for flap elevation. No discomfort, early surgical complications or unexpected events were observed. The effectiveness of this minimally-invasive surgical technique can offer the clinician a valid alternative to other methods currently in use.
Feldkamp, Michael D.; O'Donnell, Susan E.; Yu, Liping; Shea, Madeline A.
2010-01-01
Trifluoperazine (TFP; Stelazine™) is an antagonist of calmodulin (CaM), an essential regulator of calcium-dependent signal transduction. Reports differ regarding whether, or where, TFP binds to apo CaM. Three crystallographic structures (1CTR, 1A29, 1LIN) show TFP bound to (Ca2+)4-CaM in ratios of 1, 2 or 4 TFP per CaM. In all of these, CaM domains adopt the “open” conformation seen in CaM-kinase complexes having increased calcium affinity. Most reports suggest TFP also increases calcium affinity of CaM. To compare TFP binding to apo CaM and (Ca2+)4-CaM, and explore differential effects on the N- and C-domains of CaM, stoichiometric TFP titrations of CaM were monitored by 15N-HSQC NMR. Two TFP bound to apo CaM, while four bound to (Ca2+)4-CaM. In both cases, the preferred site was in the C-domain. During the titrations, biphasic responses for some resonances suggested inter-site interactions. TFP-binding sites in apo CaM appeared distinct from those in (Ca2+)4-CaM. In equilibrium calcium titrations at defined ratios of TFP:CaM, TFP reduced calcium affinity at most levels tested; this is similar to the effect of many IQ-motifs on CaM. However, at the highest level tested, TFP raised the calcium affinity of the N-domain of CaM. A model of conformational switching is proposed to explain how TFP can exert opposing allosteric effects on calcium affinity by binding to different sites in the “closed”, “semi-open” and “open” domains of CaM. In physiological processes, apo CaM, as well as (Ca2+)4-CaM, needs to be considered a potential target of drug action. PMID:20544963
ERIC Educational Resources Information Center
Jobes, David A.
2012-01-01
The Collaborative Assessment and Management of Suicidality (CAMS) is an evidence-based clinical intervention that has significantly evolved over 25 years of clinical research. CAMS is best understood as a therapeutic framework that emphasizes a unique collaborative assessment and treatment planning process between the suicidal patient and…
Positioning and locking apparatus
Hayward, M.L.; Harper, W.H.
1987-06-30
A positioning and locking apparatus are disclosed including a fixture having a rotatable torque ring provided with a plurality of cam segments for automatically guiding a container into a desired location within the fixture. Rotation of the ring turns the container into a final position in pressure sealing relation against a hatch member. 6 figs.
Comparison of denture base adaptation between CAD-CAM and conventional fabrication techniques.
Goodacre, Brian J; Goodacre, Charles J; Baba, Nadim Z; Kattadiyil, Mathew T
2016-08-01
Currently no data comparing the denture base adaptation of CAD-CAM and conventional denture processing techniques have been reported. The purpose of this in vitro study was to compare the denture base adaptation of pack and press, pour, injection, and CAD-CAM techniques for fabricating dentures to determine which process produces the most accurate and reproducible adaptation. A definitive cast was duplicated to create 40 gypsum casts that were laser scanned before any fabrication procedures were initiated. A master denture was made using the CAD-CAM process and was then used to create a putty mold for the fabrication of 30 standardized wax festooned dentures, 10 for each of the conventional processing techniques (pack and press, pour, injection). Scan files from 10 casts were sent to Global Dental Science, LLC for fabrication of the CAD-CAM test specimens. After specimens for each of the 4 techniques had been fabricated, they were hydrated for 24 hours and the intaglio surface laser scanned. The scan file of each denture was superimposed on the scan file of the corresponding preprocessing cast using surface matching software. Measurements were made at 60 locations, providing evaluation of fit discrepancies at the following areas: apex of the denture border, 6 mm from the denture border, crest of the ridge, palate, and posterior palatal seal. The use of median and interquartile range was used to assess accuracy and reproducibility. The Levine and Kruskal-Wallis analysis of variance was used to evaluate differences between processing techniques at the 5 specified locations (α=.05). The ranking of results based on median and interquartile range determined that the accuracy and reproducibility of the CAD-CAM technique was more consistently localized around zero at 3 of the 5 locations. Therefore, the CAD-CAM technique showed the best combination of accuracy and reproducibility among the tested fabrication techniques. The pack and press technique was more accurate at 2 of the 5 locations; however, its interquartile range (reproducibility) was the greatest of the 4 tested processing techniques. The pour technique was the most reproducible at 2 of the 5 locations; however, its accuracy was the lowest of the tested techniques. The CAD-CAM fabrication process was the most accurate and reproducible denture fabrication technique when compared with pack and press, pour, and injection denture base processing techniques. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
[An experimental research on the fabrication of the fused porcelain to CAD/CAM molar crown].
Dai, Ning; Zhou, Yongyao; Liao, Wenhe; Yu, Qing; An, Tao; Jiao, Yiqun
2007-02-01
This paper introduced the fabrication process of the fused porcelain to molar crown with CAD/CAM technology. Firstly, preparation teeth data was retrieved by the 3D-optical measuring system. Then, we have reconstructed the inner surface designed the outer surface shape with the computer aided design software. Finally, the mini high-speed NC milling machine was used to produce the fused porcelain to CAD/CAM molar crown. The result has proved that the fabrication process is reliable and efficient. The dental restoration quality is steady and precise.
Nozawa, Kenji; Iwao, Yasunori; Noguchi, Shuji; Itai, Shigeru
2015-11-10
To generate products containing a stable form of clarithromycin (CAM) (form II) regardless of the initial crystal form of CAM or type of granulation solvent, the effects of five surfactants, or a water-soluble polymer (macrogol 400) were determined on the crystal transition of CAM. The metastable form (form I) was kneaded with water, after adding surfactants, or a water-soluble polymer. Form II was also kneaded with ethanol, after adding the same additives. The resulting samples were analyzed by powder X-ray diffraction. Form I was completely converted to form II by a wet granulation using water with additives bearing polyoxyethylene chains such as polysorbate 80 (PS80), polyoxyl 40 stearate or macrogol 400. The granulation of the form II using ethanol with these additives did not result in a crystal transition to form I. Furthermore, CAM tablets were manufactured using granules with PS80, and these crystal forms and dissolution behaviors were investigated. As a result, the wet granulation of CAM with PS80 gave CAM tablets containing only form II and PS80 did not have any adverse effects on tablet characteristics. Therefore, these data suggests that the crystal form of CAM can be controlled to be form II using a wet granulation process with additives bearing polyoxyethylene chains regardless of the initial crystal form of CAM or type of granulation solvent. Copyright © 2015 Elsevier B.V. All rights reserved.
Mahling, Ryan; Kilpatrick, Adina M; Shea, Madeline A
2017-10-01
Human voltage-gated sodium channel Na V 1.2 has a single pore-forming α-subunit and two transmembrane β-subunits. Expressed primarily in the brain, Na V 1.2 is critical for initiation and propagation of action potentials. Milliseconds after the pore opens, sodium influx is terminated by inactivation processes mediated by regulatory proteins including calmodulin (CaM). Both calcium-free (apo) CaM and calcium-saturated CaM bind tightly to an IQ motif in the C-terminal tail of the α-subunit. Our thermodynamic studies and solution structure (2KXW) of a C-domain fragment of apo 13 C, 15 N- CaM (CaM C ) bound to an unlabeled peptide with the sequence of rat Na V 1.2 IQ motif showed that apo CaM C (a) was necessary and sufficient for binding, and (b) bound more favorably than calcium-saturated CaM C . However, we could not monitor the Na V 1.2 residues directly, and no structure of full-length CaM (including the N-domain of CaM (CaM N )) was determined. To distinguish contributions of CaM N and CaM C , we used solution NMR spectroscopy to assign the backbone resonances of a complex containing a 13 C, 15 N-labeled peptide with the sequence of human Na V 1.2 IQ motif (Na V 1.2 IQp ) bound to apo 13 C, 15 N-CaM or apo 13 C, 15 N-CaM C . Comparing the assignments of apo CaM in complex with Na V 1.2 IQp to those of free apo CaM showed that residues within CaM C were significantly perturbed, while residues within CaM N were essentially unchanged. The chemical shifts of residues in Na V 1.2 IQp and in the C-domain of CaM were nearly identical regardless of whether CaM N was covalently linked to CaM C . This suggests that CaM N does not influence apo CaM binding to Na V 1.2 IQp .
Mechanical properties and superficial characterization of a milled CAD-CAM glass fiber post.
Ruschel, George Hebert; Gomes, Érica Alves; Silva-Sousa, Yara Terezinha; Pinelli, Rafaela Giedra Pirondi; Sousa-Neto, Manoel Damião; Pereira, Gabriel Kalil Rocha; Spazzin, Aloísio Oro
2018-06-01
Computer-aided design and computer-aided manufacturing (CAD-CAM) technology may be used to produce custom intraradicular posts, but studies are lacking. The purpose of this in vitro study was to evaluate the flexural properties (strength and modulus), failure mode, superficial morphology, and roughness of two CAD-CAM glass fiber posts (milled at different angulations) compared with a commercially available prefabricated glass fiber post. Three groups were tested (n = 10): PF (control group)- prefabricated glass fiber post; C-Cd-diagonally milled post; and C-Cv-vertically milled post. A 3-dimensional virtual image was obtained from a prefabricated post, which guided the posterior milling of posts from a glass fiber disk (Trilor Blanks; Bioloren). Surface roughness and morphology were evaluated using confocal laser microscopy. Flexural strength and modulus were evaluated with the 3-point bend test. Data were submitted to one-way analysis of variance followed by the Student-Newman-Keuls post hoc test (α = 0.05). The fractured surfaces were evaluated with scanning electron microscopy. The superficial roughness was highest for PF and similar for the experimental groups. Morphological analysis shows different sizes and directions of the glass fibers along the post. The flexural strength was highest for PF (900.1 ± 30.4 > C-Cd - 357.2 ± 30.7 > C-Cv 101.8 ± 4.3 MPa) as was the flexural modulus (PF 19.3 ± 2.0 GPa > C-Cv 10.1 ± 1.9 GPa > C-Cd 7.8 ± 1.3 GPa). A CAD-CAM milled post seems a promising development, but processing requires optimizing, as the prefabricated post still shows better mechanical properties and superficial characteristics. Copyright © 2018 Elsevier Ltd. All rights reserved.
Digital impression and jaw relation record for the fabrication of CAD/CAM custom tray.
Kanazawa, Manabu; Iwaki, Maiko; Arakida, Toshio; Minakuchi, Shunsuke
2018-03-16
This article describes the protocol of a digital impression technique to make an impression and recording of the jaw relationship of edentulous patients for the fabrication of CAD/CAM custom tray using computer-aided design and manufacturing (CAD/CAM) technology. Scan the maxillary and mandibular edentulous jaws using an intraoral scanner. Scan the silicone jig with the maxillary and mandibular jaws while keeping the jig between the jaws. Import the standard tessellation language data of the maxillary and mandibular jaws and jig to make a jaw relation record and fabricate custom trays (CAD/CAM trays) using a rapid prototyping system. Make a definitive impression of the maxillary and mandibular jaws using the CAD/CAM trays. Digitalization of the complete denture fabrication process can simplify the complicated treatment and laboratory process of conventional methods In addition, the proposed method enables quality control regardless of the operator's experience and technique. Copyright © 2018. Published by Elsevier Ltd.
Gilmour, Joan; Harrison, Christine; Vohra, Sunita
2011-11-01
Our goal for this supplemental issue of Pediatrics was to consider what practitioners, parents, patients, institutions, and policy-makers need to take into account to make good decisions about using complementary and alternative medicine (CAM) to treat children and to develop guidelines for appropriate use. We began by explaining underlying concepts and principles in ethical, legal, and clinical reasoning and then used case scenarios to explore how they apply and identify gaps that remain in practice and policy. In this concluding article, we review our major findings, summarize our recommendations, and suggest further research. We focus on several key areas: practitioner and patient/parent relationships; decision-making; dispute resolution; standards of practice; hospital/health facility policies; patient safety; education; and research. Ethical principles, standards, and rules applicable when making decisions about conventional care for children apply to decision-making about CAM as well. The same is true of legal reasoning. Although CAM use has seldom led to litigation, general legal principles relied on in cases involving conventional medical care provide the starting point for analysis. Similarly, with respect to clinical decision-making, clinicians are guided by clinical judgment and the best interests of their patient. Whether a therapy is CAM or conventional, clinicians must weigh the relative risks and benefits of therapeutic options and take into account their patient's values, beliefs, and preferences. Consequently, many of our observations apply to conventional and CAM care and to both adult and pediatric patients.
1985-10-08
processing and modification of In each gene the respective nonapeptide opioid peptide precursors. He reported was found to occupy the first of three that gene...function has been cules. The researchers have identified highly conserved among chordates and at least three distinct N-CAM, polypep- that N-CAM-like...called D2 al antibodies they have cloned several when first discovered by Bock. She N-CAM related cDNAs. These investiga- L examined N-CAM in cultured
Turnkey CAD/CAM systems' integration with IPAD systems
NASA Technical Reports Server (NTRS)
Blauth, R. E.
1980-01-01
Today's commercially available turnkey CAD/CAM systems provide a highly interactive environment, and support many specialized application functions for the design/drafting/manufacturing process. This paper presents an overview of several aerospace companies which have successfully integrated turnkey CAD/CAM systems with their own company wide engineering and manufacturing systems. It also includes a vendor's view of the benefits as well as the disadvantages of such integration efforts. Specific emphasis is placed upon the selection of standards for representing geometric engineering data and for communicating such information between different CAD/CAM systems.
Vct system having closed loop control employing spool valve actuated by a stepper motor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Quin, S.B. Jr.; Siemon, E.C.
1993-06-15
An internal combustion engine is described comprising: a crankshaft, the crankshaft being rotable about an axis; a cam shaft, the cam shaft being rotatable about a second axis, the second axis being parallel to the axis, the cam shaft being subject to torque reversals during the rotation thereof; a vane, the vane having at least one lobe, the vane being attached to the cam shaft, being rotatable with the cam shaft and being non-oscillatable with respect to the cam shaft; a housing, the housing being rotatable with the cam shaft and being oscillatable with respect to the cam shaft, themore » housing having at least one recess, the recess receiving the lobe, the lobe being oscillatable within the recess; rotary movement transmitting means for transmitting rotary movement from the crankshaft to the housing; actuating means for varying the position of the housing relative to the cam shaft in reaction to torque reversals in the cam shaft, the actuating means comprising a stepper motor, a lead screw and a proportional spool valve, the position of the spool valve being controlled by the position of the lead screw driven by the stepper motor, the actuating means also delivering hydraulic fluid to the vane; and processing means for controlling the position of the actuating means.« less
Kretchy, Irene A; Okere, Harry A; Osafo, Joseph; Afrane, Barima; Sarkodie, Joseph; Debrah, Philip
2016-09-01
Integrative medicine refers to ongoing efforts to combine the best of conventional and evidence-based complementary therapies. While this effort for collaboration is increasing, traditional complementary and alternative medicine (TM-CAM) remains poorly integrated into the current healthcare system of Ghana. At present, it is not clear if practitioners of mainstream medicine favor integrative medicine. The present study, therefore, sought to explore the perceptions of conventional healthcare professionals on integrative medicine. A qualitative design composed of semi-structured interviews was conducted with 23 conventional healthcare professionals comprising pharmacists, physicians, nurses and dieticians from two quasi-government hospitals in Accra, Ghana. Participants' knowledge of TM-CAM was low, and although they perceived alternative medicine as important to current conventional healthcare in Ghana, they expressed anxieties about the potential negative effects of the use of TM-CAM. This paradox was found to account for the low levels of use among these professionals, as well as the low level of recommendation to their patients. The practitioners surveyed recommended that alternative medicine could be integrated into mainstream allopathic healthcare in Ghana through improving knowledge, training as well as addressing concerns of safety and efficacy. These findings are discussed under the themes: the knowledge gap, the paradox of TM-CAM, experience of use and prescription, and guided integration. We did not observe any differences in views among the participants. The conventional healthcare professionals were ready to accept the idea of integrative medicine based on knowledge of widespread use and the potential role of TM-CAM products and practices in improving healthcare delivery in the country. However, to achieve an institutional integration, practitioners' understanding of TM-CAM must be improved, with specific attention to issues of safety, regulation and evidence-based practice of TM-CAM products and services in Ghana.
USDA-ARS?s Scientific Manuscript database
Bioassay-guided fractionation of an extract prepared from the culture medium and mycelium of Purpureocillium lilacinum allowed the isolation of two calmodulin (CaM) inhibitors, namely, acremoxanthone C (1) and acremonidin A (2). The absolute configuration of 1 was established as 2R, 3R, 1'S, 11'S, ...
Caging Mechanism for a drag-free satellite position sensor
NASA Technical Reports Server (NTRS)
Hacker, R.; Mathiesen, J.; Debra, D. B.
1976-01-01
A disturbance compensation system for satellites based on the drag-free concept was mechanized and flown, using a spherical proof mass and a cam-guided caging mechanism. The caging mechanism controls the location of the proof mass for testing and constrains it during launch. Design requirements, design details, and hardware are described.
NASA Astrophysics Data System (ADS)
Tang, W.; Arellano, A. F., Jr.; Choi, Y.; DiGangi, J. P.; Woo, J. H.; Diskin, G. S.; Agusti-panareda, A.; Parrington, M.; Massart, S.; Lee, M.; Kanaya, Y.; Jang, J.; Lee, Y.; Hong, J.; Flynn, J. H., III; Thompson, A. M.; Kim, D. B.
2017-12-01
Anthropogenic combustion has significant impacts on air quality and climate. To understand anthropogenic combustion, it is critical to model CO2 and CO (key combustion signatures) and their relationships. In this study, we jointly evaluate the Copernicus Atmosphere Monitoring Service (CAMS) free-running 16-km forecast, 9-km forecast initialized with CAMS analysis, and analysis products of CO (80km) and CO2 (40km) to understand how well combustion-related processes and constituent transport are represented in the current system. We use measurements from aircraft, ground sites, and ships during the KORUS-AQ field campaign (May - June 2016), along with satellite observations (MOPITT, IASI, OCO-2, and GOSAT). Airborne measurements by the DC-8 aircraft are classified into five regions: Seoul metropolitan, Taehwa, West Sea, Seoul-Jeju jetway, and Seoul-Busan jetway. The observed CO2, CO, and their relationships varies significantly, and the performance of CAMS products also varies across regions. The three CAMS products perform reasonably well in simulating anthropogenic combustion processes. Overall, CO2 is overestimated while CO is underestimated by CAMS. The 9km forecast product generally has a better performance than the other two, because of its higher model resolution and better initialization conditions. The analysis product also performs better than the 16km forecast. China outflow over West Sea is captured, but CO2 and CO is underestimated in the outflow. According to CAMS, is 10-15 (ppbv/ppmv) for Korea and about 30 for China outflow, indicating anthropogenic combustion in Seoul is more efficient than it is in China. This agrees well with DC-8 aircraft observations. As for ground sites, we find that CO and CO2 measured by the Olympic park and Yonsei (Seoul metropolitan sites) have more regularity in diurnal cycle, and such periodical change is well captured by CAMS. The time series for CO from Baengnyeong, and Fukue (remote sites) are irregular and episodic, which are more related to transport rather than local emissions. CAMS performances over Taehwa site are impacted by both local processes and transport. These comparisons indicate vertical mixing near sources may be an issue for CAMS. Compared to satellite observations, CO analyses show a better agreement, while for CO2, the forecasts are better.
New generation of content addressable memories for associative processing
NASA Astrophysics Data System (ADS)
Lewis, H. G., Jr.; Giambalov, Paul
2000-05-01
Content addressable memories (CAMS) store both key and association data. A key is presented to the CAN when it is searched and all of the addresses are scanned in parallel to find the address referenced by the key. When a match occurs, the corresponding association is returned. With the explosion of telecommunications packet switching protocols, large data base servers, routers and search engines a new generation of dense sub-micron high throughput CAMS has been developed. The introduction of this paper presents a brief history and tutorial on CAMS, their many uses and advantages, and describes the architecture and functionality of several of MUSIC Semiconductors CAM devices. In subsequent sections of the paper we address using Associative Processing to accommodate the continued increase in sensor resolution, number of spectral bands, required coverage, the desire to implement real-time target cueing, and the data flow and image processing required for optimum performance of reconnaissance and surveillance Unmanned Aerial Vehicles (UAVs). To be competitive the system designer must provide the most computational power, per watt, per dollar, per cubic inch, within the boundaries of cost effective UAV environmental control systems. To address these problems we demonstrate leveraging DARPA and DoD funded Commercial Off-the-Shelf technology to integrate CAM based Associative Processing into a real-time heterogenous multiprocessing system for UAVs and other platforms with limited weight, volume and power budgets.
An automated qualification framework for the MeerKAT CAM (Control-And-Monitoring)
NASA Astrophysics Data System (ADS)
van den Heever, Lize; Marais, Neilen; Slabber, Martin
2016-08-01
This paper introduces and discusses the design of an Automated Qualification Framework (AQF) that was developed to automate as much as possible of the formal Qualification Testing of the Control And Monitoring (CAM) subsystem of the 64 dish MeerKAT radio telescope currently under construction in the Karoo region of South Africa. The AQF allows each Integrated CAM Test to reference the MeerKAT CAM requirement and associated verification requirement it covers and automatically produces the Qualification Test Procedure and Qualification Test Report from the test steps and evaluation steps annotated in the Integrated CAM Tests. The MeerKAT System Engineers are extremely happy with the AQF results, but mostly by the approach and process it enforces.
González-Andrade, Martin; Rodríguez-Sotres, Rogelio; Madariaga-Mazón, Abraham; Rivera-Chávez, José; Mata, Rachel; Sosa-Peinado, Alejandro; Del Pozo-Yauner, Luis; Arias-Olguín, Imilla I
2016-01-01
In order to contribute to the structural basis for rational design of calmodulin (CaM) inhibitors, we analyzed the interaction of CaM with 14 classic antagonists and two compounds that do not affect CaM, using docking and molecular dynamics (MD) simulations, and the data were compared to available experimental data. The Ca(2+)-CaM-Ligands complexes were simulated 20 ns, with CaM starting in the "open" and "closed" conformations. The analysis of the MD simulations provided insight into the conformational changes undergone by CaM during its interaction with these ligands. These simulations were used to predict the binding free energies (ΔG) from contributions ΔH and ΔS, giving useful information about CaM ligand binding thermodynamics. The ΔG predicted for the CaM's inhibitors correlated well with available experimental data as the r(2) obtained was 0.76 and 0.82 for the group of xanthones. Additionally, valuable information is presented here: I) CaM has two preferred ligand binding sites in the open conformation known as site 1 and 4, II) CaM can bind ligands of diverse structural nature, III) the flexibility of CaM is reduced by the union of its ligands, leading to a reduction in the Ca(2+)-CaM entropy, IV) enthalpy dominates the molecular recognition process in the system Ca(2+)-CaM-Ligand, and V) the ligands making more extensive contact with the protein have higher affinity for Ca(2+)-CaM. Despite their limitations, docking and MD simulations in combination with experimental data continue to be excellent tools for research in pharmacology, toward a rational design of new drugs.
Expression of calmodulin mRNA in rat olfactory neuroepithelium.
Biffo, S; Goren, T; Khew-Goodall, Y S; Miara, J; Margolis, F L
1991-04-01
A calmodulin (CaM) cDNA was isolated by differential hybridization screening of a lambda gt10 library prepared from rat olfactory mucosa. This cDNA fragment, containing most of the open reading frame of the rat CaMI gene, was subcloned and used to characterize steady-state expression of CaM mRNA in rat olfactory neuroepithelium and bulb. Within the bulb mitral cells are the primary neuronal population expressing CaM mRNA. The major CaM mRNA expressed in the olfactory mucosa is 1.7 kb with smaller contributions from mRNAs of 4.0 and 1.4 kb. CaM mRNA was primarily associated with the olfactory neurons and, despite the cellular complexity of the tissue and the known involvement of CaM in diverse cellular processes, was only minimally evident in sustentacular cells, gland cells or respiratory epithelium. Following bulbectomy CaM mRNA declines in the olfactory neuroepithelium as does olfactory marker protein (OMP) mRNA. In contrast to the latter, CaM mRNA makes a partial recovery by one month after surgery. These results, coupled with those from in situ hybridization, indicate that CaM mRNA is expressed in both mature and immature olfactory neurons. The program regulating CaM gene expression in olfactory neurons is distinct from those controlling expression of B50/GAP43 in immature, or OMP in mature, neurons respectively.
2014-01-01
The use of complementary and alternative Medicine (CAM) has increased over the past two decades in Europe. Nonetheless, research investigating the evidence to support its use remains limited. The CAMbrella project funded by the European Commission aimed to develop a strategic research agenda starting by systematically evaluating the state of CAM in the EU. CAMbrella involved 9 work packages covering issues such as the definition of CAM; its legal status, provision and use in the EU; and a synthesis of international research perspectives. Based on the work package reports, we developed a strategic and methodologically robust research roadmap based on expert workshops, a systematic Delphi-based process and a final consensus conference. The CAMbrella project suggests six core areas for research to examine the potential contribution of CAM to the health care challenges faced by the EU. These areas include evaluating the prevalence of CAM use in Europe; the EU cititzens’ needs and attitudes regarding CAM; the safety of CAM; the comparative effectiveness of CAM; the effects of meaning and context on CAM outcomes; and different models for integrating CAM into existing health care systems. CAM research should use methods generally accepted in the evaluation of health services, including comparative effectiveness studies and mixed-methods designs. A research strategy is urgently needed, ideally led by a European CAM coordinating research office dedicated to fostering systematic communication between EU governments, the public, charitable and industry funders, researchers and other stakeholders. A European Centre for CAM should also be established to monitor and further a coordinated research strategy with sufficient funds to commission and promote high quality, independent research focusing on the public’s health needs and pan-European collaboration. There is a disparity between highly prevalent use of CAM in Europe and solid knowledge about it. A strategic approach on CAM research should be established to investigate the identified gaps of knowledge and to address upcoming health care challenges. PMID:24499316
Adhesion mechanisms in embryogenesis and in cancer invasion and metastasis.
Thiery, J P; Boyer, B; Tucker, G; Gavrilovic, J; Valles, A M
1988-01-01
Cell-substratum and cell-cell adhesion mechanisms contribute to the development of animal form. The adhesive status of embryonic cells has been analysed during epithelial-mesenchymal cell interconversion and in cell migrations. Clear-cut examples of the modulation of cell adhesion molecules (CAMs) have been described at critical periods of morphogenesis. In chick embryos the three primary CAMs (N-CAM. L-CAM and N-cadherin) present early in embryogenesis are expressed later in a defined pattern during morphogenesis and histogenesis. The axial mesoderm derived from gastrulating cells expresses increasing amounts of N-cadherin and N-CAM. During metamerization these two adhesion molecules become abundant at somitic cell surfaces. Both CAMs are functional in an in vitro aggregation assay; however, the calcium-dependent adhesion molecule N-cadherin is more sensitive to perturbation by specific antibodies. Neural crest cells which separate from the neural epithelium lose their primary CAMs in a defined time-sequence. Adhesion to fibronectins via specific surface receptors becomes a predominant interaction during the migratory process, while some primary and secondary CAMs are expressed de novo during the ontogeny of the peripheral nervous system. In vitro, different fibronectin functional domains have been identified in the attachment, spreading and migration of neural crest cells. The fibronectin receptors which transduce the adhesive signals play a key role in the control of cell movement. All these results have prompted us to examine whether similar mechanisms operate in carcinoma cell invasion and metastasis. In vitro, rat bladder transitional carcinoma cells convert reversibly into invasive mesenchymal cells. A rapid modulation of adhesive properties is found during the epithelial-mesenchymal carcinoma cell interconversion. The different model systems analysed demonstrate that a limited repertoire of adhesion molecules, expressed in a well-defined spatiotemporal pattern, is involved in tissue formation and in key processes of tumour spread.
How do parents of children with juvenile idiopathic arthritis (JIA) perceive their therapies?
Rouster-Stevens, Kelly; Nageswaran, Savithri; Arcury, Thomas A; Kemper, Kathi J
2008-06-02
Complementary and alternative medical (CAM) therapies are commonly used by pediatric patients with chronic medical conditions. Little is known about parents' perceptions of these therapies. This study describes the views of parents of patients with juvenile idiopathic arthritis (JIA) regarding conventional and CAM therapies. Parents of children with JIA seen at a pediatric rheumatology clinic were surveyed between June 1 and July 31, 2007. Questionnaires asked about patients' use of over 75 therapies in the past 30 days, their perceived helpfulness (0 = not helpful; 3 = very helpful), perceived side effects (0 = none; 3 = severe), and whether each therapy would be recommended to other patients with JIA (Yes, No, Not sure). Questionnaires were returned by 52/76 (68%) parents; patients' average age was 10.9 years and 87% were Caucasian. Medications were used by 45 (88%) patients; heat (67%) and extra rest (54%) were also commonly used. CAM therapies were used by 48 (92%), e.g., massage (54%), vitamins and other supplements (54%), avoiding foods that worsened pain (35%) and stress management techniques (33%). Among the therapies rated by 3 or more parents, those that scored 2.5 or higher on helpfulness were: biologic medications, methotrexate, naproxen, wheelchairs, orthotics, heat, vitamins C and D, music, support groups and prayer. CAM therapies had 0 median side effects and parents would recommend many of them to other families. JIA patients use diverse therapies. Parents report that many CAM therapies are helpful and would recommend them to other parents. These data can be used in counseling patients and guiding future research.
Resin-composite blocks for dental CAD/CAM applications.
Ruse, N D; Sadoun, M J
2014-12-01
Advances in digital impression technology and manufacturing processes have led to a dramatic paradigm shift in dentistry and to the widespread use of computer-aided design/computer-aided manufacturing (CAD/CAM) in the fabrication of indirect dental restorations. Research and development in materials suitable for CAD/CAM applications are currently the most active field in dental materials. Two classes of materials are used in the production of CAD/CAM restorations: glass-ceramics/ceramics and resin composites. While glass-ceramics/ceramics have overall superior mechanical and esthetic properties, resin-composite materials may offer significant advantages related to their machinability and intra-oral reparability. This review summarizes recent developments in resin-composite materials for CAD/CAM applications, focusing on both commercial and experimental materials. © International & American Associations for Dental Research.
Preparing for High Technology: CAD/CAM Programs. Research & Development Series No. 234.
ERIC Educational Resources Information Center
Abram, Robert; And Others
This guide is one of three developed to provide information and resources to assist in planning and developing postsecondary technican training programs in high technology areas. It is specifically intended for vocational-technical educators and planners in the initial stages of planning a specialized training option in computer-aided design (CAD)…
Understanding dental CAD/CAM for restorations--accuracy from a mechanical engineering viewpoint.
Tapie, Laurent; Lebon, Nicolas; Mawussi, Bernardin; Fron-Chabouis, Hélène; Duret, Francois; Attal, Jean-Pierre
2015-01-01
As is the case in the field of medicine, as well as in most areas of daily life, digital technology is increasingly being introduced into dental practice. Computer-aided design/ computer-aided manufacturing (CAD/CAM) solutions are available not only for chairside practice but also for creating inlays, crowns, fixed partial dentures (FPDs), implant abutments, and other dental prostheses. CAD/CAM dental practice can be considered as the handling of devices and software processing for the almost automatic design and creation of dental restorations. However, dentists who want to use dental CAD/CAM systems often do not have enough information to understand the variations offered by such technology practice. Knowledge of the random and systematic errors in accuracy with CAD/CAM systems can help to achieve successful restorations with this technology, and help with the purchasing of a CAD/CAM system that meets the clinical needs of restoration. This article provides a mechanical engineering viewpoint of the accuracy of CAD/ CAM systems, to help dentists understand the impact of this technology on restoration accuracy.
Håkansson, Joakim; Xian, Xiaojie; He, Liqun; Ståhlberg, Anders; Nelander, Sven; Samuelsson, Tore; Kubista, Mikael; Semb, Henrik
2005-01-01
To understand by which mechanism neural cell adhesion molecule (N-CAM) limits beta tumour cell disaggregation and dissemination, we searched for potential downstream genes of N-CAM during beta tumour cell progression by gene expression profiling. Here, we show that N-CAM-deficient beta-cell tumorigenesis is associated with changes in the expression of genes involved in cell-matrix adhesion and cytoskeletal dynamics, biological processes known to affect the invasive and metastatic behaviour of tumour cells. The extracellular matrix (ECM) molecules emerged as the primary target, i.e. N-CAM deficiency resulted in down-regulated mRNA expression of a broad range of ECM molecules. Consistent with this result, deficient deposition of major ECM stromal components, such as fibronectin, laminin 1 and collagen IV, was observed. Moreover, N-CAM-deficient tumour cells displayed defective matrix adhesion. These results offer a potential mechanism for tumour cell disaggregation during N-CAM-deficient beta tumour cell progression. Prospective consequences of these findings for the role of N-CAM in beta tumour cell dissemination are discussed.
Shreffler-Grant, Jean; Nichols, Elizabeth; Weinert, Clarann; Ide, Bette
2016-01-01
This article aims to present and describe a model of complementary and alternative medicine (CAM) health literacy. The model is the conceptual basis for CAM health literacy, which is operationally defined as the information about CAM needed to make informed self-management decisions regarding health. Improving health literacy is a national priority, and widespread use of CAM has added to the complexity of this task. There are no currently available models or measures of health literacy regarding CAM. The authors developed the model using an iterative process of deriving concepts, constructs, and empirical indicators from the literature and the author’s prior work, review and critique by experts, and revision. The model of CAM health literacy can serve as the basis for future research on the use and efficacy of CAM and the constructs and concepts within it can be used to identify points of intervention for research or for clinical practice. It is anticipated that the model will have scientific and clinical application for assessing health literacy in other self care decision-making situations. PMID:23889542
Shreffler-Grant, Jean; Nichols, Elizabeth; Weinert, Clarann; Ide, Bette
2013-01-01
This article aims to present and describe a model of complementary and alternative medicine (CAM) health literacy. The model is the conceptual basis for CAM health literacy, which is operationally defined as the information about CAM needed to make informed self-management decisions regarding health. Improving health literacy is a national priority, and widespread use of CAM has added to the complexity of this task. There are no currently available models or measures of health literacy regarding CAM. The authors developed the model using an iterative process of deriving concepts, constructs, and empirical indicators from the literature and the author's prior work, review and critique by experts, and revision. The model of CAM health literacy can serve as the basis for future research on the use and efficacy of CAM and the constructs and concepts within it can be used to identify points of intervention for research or for clinical practice. It is anticipated that the model will have scientific and clinical application for assessing health literacy in other self care decision-making situations.
Software Tools for Shipbuilding Productivity
1984-12-01
shipbuilding, is that design, manufacturing and robotic technology applications to shipbuilding have been proven. all aspects of shipbuilding is now a task...technical information about the process of Computer Aided Design (CAD) and Computer Aided Manufacturing (CAM) effectively has been a problem of serious and...Design (CAD) 3.4.1 CAD System Components 3.4.2 CAD System Benefits 3.4.3 New and Future CAD Technologies Computer Aided Manufacturing (CAM) 3.5.1 CAM
Loss of membranous Ep-CAM in budding colorectal carcinoma cells.
Gosens, Marleen J E M; van Kempen, Léon C L; van de Velde, Cornelis J H; van Krieken, J Han J M; Nagtegaal, Iris D
2007-02-01
Tumor budding is a histological feature that reflects loss of adhesion of tumor cells and is associated with locoregional metastasis of colorectal carcinoma. Although nuclear localization of beta-catenin is associated with tumor budding, the molecular mechanism remains largely elusive. In this study, we hypothesize that the epithelial cell adhesion molecule (Ep-CAM) is involved in tumor budding. In order to address this question, we performed immunohistochemistry on Ep-CAM using three different antibodies (monoclonal antibodies Ber-ep4 and 311-1K1 and a polyclonal antibody) and a double staining on beta-catenin and Ep-CAM. In addition, Ep-CAM mRNA was monitored with mRNA in situ hybridization. Subsequently, we determined the effect of Ep-CAM staining patterns on tumor spread in rectal cancer. In contrast to the tumor mass, budding cells of colorectal carcinoma displayed lack of membranous but highly increased cytoplasmic Ep-CAM staining and nuclear translocation of beta-catenin. mRNA in situ hybridization suggested no differences in Ep-CAM expression between the invasive front and the tumor mass. Importantly, reduced Ep-CAM staining at the invasive margin of rectal tumor specimens (n=133) correlated significantly with tumor budding, tumor grade and an increased risk of local recurrence (P=0.001, P=0.04 and P=0.03, respectively). These data demonstrate abnormal processing of Ep-CAM at the invasive margin of colorectal carcinomas. Our observations indicate that loss of membranous Ep-CAM is associated with nuclear beta-catenin localization and suggest that this contributes to reduced cell-cell adhesions, increased migratory potential and tumor budding.
Klafke, Nadja; Eliott, Jaklin A; Olver, Ian N; Wittert, Gary A
2014-06-01
To explore how men's Significant Others (SOs), including family members and close friends, contribute to the uptake and maintenance of specific CAM therapies. This study was the second, qualitative phase of a mixed-methods project investigating the use of CAM in an Australian male cancer population. Male participants were purposefully selected from a pool of 403 patients who answered a survey in the first quantitative phase (94% response rate and 86% consent rate for follow-up interview). Then semi-structured interviews among 26 men with a variety of cancers and 24 SOs were conducted. All 43 interviews were recorded, transcribed, and analysed thematically. Men used CAM/Natural products to cope with physical concerns, and this was actively supported by men's SOs who contributed to the uptake and maintenance of these CAMs. The shared CAM preparation and consumption functioned to strengthen the bond between men and their SOs, and also helped men's SOs to cope with uncertainty and regain control. In contrast, men practiced CAM/Mind-body medicine to receive emotional benefits, and only rarely shared this practice with their SOs, indicating a need for coping with emotions in a private way. Men's CAM use is a multifaceted process that can be better understood by considering CAM categories separately. CAM/Natural products help men to cope with physical concerns, while CAM/Mind-body medicine assist men to cope with their emotions in a private way. Oncology professionals can use this information to better promote and implement integrative cancer care services. Copyright © 2014 Elsevier Ltd. All rights reserved.
As-built design specification for CAMS Development Dot Data System (CDDDS)
NASA Technical Reports Server (NTRS)
Wehmanen, O. A.
1979-01-01
The CAMS development dot data system is described. Listings and flow charts of the eight programs used to maintain the data base and the 15 subroutines used in FORTRAN programs to process the data are presented.
Agarwal, Vinita
2018-06-05
The study aim was to understand the patient description of the therapeutic relationship with their CAM provider in the context of pain self-management. Because pain is a subjective state, its assessment depends on patient perception of and response to pain. For nurses to provide empathetic and compassionate care, there is a need to explicate patient perceptions of the therapeutic relationship to (re)conceptualize models of patient-centered care. Inductive qualitative content analysis of patient interviews was conducted to identify how patients described therapeutic relationship themes and understand self-management of pain. Participants were individuals working with a CAM practitioner and solicited through purposive and snowball sampling in collaboration with the practitioners from the mid-Atlantic region of the United States in 2016 (N=13). Verbatim transcriptions of audio-recorded semi-structured in-depth interviews (430 single-spaced pages approximately) were content analyzed. Patients described the therapeutic relationship with the provider as a (a) giver, who was "in-tune" with their sense of self to support self-affirmation through empathetic listening and (b) guide, who connected the mind and body through their practice to support self-reflective learning. This description of the CAM therapeutic relationship advances understandings of readjustment of patient relationship with pain through the provider's empathetic listening and connecting the mind and the body to support patient self-affirmation of pain experiences and self-reflective learning. The findings illuminate how a feminist standpoint contributes to understandings of the therapeutic relationship that centers patient subjectivity and co-construction of meaning-making processes to support self-management of pain. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Geometric Calibration and Validation of Ultracam Aerial Sensors
NASA Astrophysics Data System (ADS)
Gruber, Michael; Schachinger, Bernhard; Muick, Marc; Neuner, Christian; Tschemmernegg, Helfried
2016-03-01
We present details of the calibration and validation procedure of UltraCam Aerial Camera systems. Results from the laboratory calibration and from validation flights are presented for both, the large format nadir cameras and the oblique cameras as well. Thus in this contribution we show results from the UltraCam Eagle and the UltraCam Falcon, both nadir mapping cameras, and the UltraCam Osprey, our oblique camera system. This sensor offers a mapping grade nadir component together with the four oblique camera heads. The geometric processing after the flight mission is being covered by the UltraMap software product. Thus we present details about the workflow as well. The first part consists of the initial post-processing which combines image information as well as camera parameters derived from the laboratory calibration. The second part, the traditional automated aerial triangulation (AAT) is the step from single images to blocks and enables an additional optimization process. We also present some special features of our software, which are designed to better support the operator to analyze large blocks of aerial images and to judge the quality of the photogrammetric set-up.
Self-organizing biopsychosocial dynamics and the patient-healer relationship.
Pincus, David
2012-01-01
The patient-healer relationship has an increasing area of interest for complementary and alternative medicine (CAM) researchers. This focus on the interpersonal context of treatment is not surprising as dismantling studies, clinical trials and other linear research designs continually point toward the critical role of context and the broadband biopsychosocial nature of therapeutic responses to CAM. Unfortunately, the same traditional research models and methods that fail to find simple and specific treatment-outcome relations are similarly failing to find simple and specific mechanisms to explain how interpersonal processes influence patient outcomes. This paper presents an overview of some of the key models and methods from nonlinear dynamical systems that are better equipped for empirical testing of CAM outcomes on broadband biopsychosocial processes. Suggestions are made for CAM researchers to assist in modeling the interactions among key process dynamics interacting across biopsychosocial scales: empathy, intra-psychic conflict, physiological arousal, and leukocyte telomerase activity. Finally, some speculations are made regarding the possibility for deeper cross-scale information exchange involving quantum temporal nonlocality. Copyright © 2012 S. Karger AG, Basel.
NASA Astrophysics Data System (ADS)
Glotsos, Dimitris; Kostopoulos, Spiros; Sidiropoulos, Konstantinos; Ravazoula, Panagiota; Kalatzis, Ioannis; Asvestas, Pantelis; Cavouras, Dionisis
2014-01-01
In this study a Computer-Aided Microscopy (CAM) system is proposed for investigating the importance of the histological criteria involved in diagnosing of cancers in microscopy in order to suggest the more informative features for discriminating low from high-grade brain tumours. Four families of criteria have been examined, involving the greylevel variations (i.e. texture), the morphology (i.e. roundness), the architecture (i.e. cellularity) and the overall tumour qualities (expert's ordinal scale). The proposed CAM system was constructed using a modified Seeded Region Growing algorithm for image segmentation, and the Probabilistic Neural Network classifier for image classification. The implementation was designed on a commercial Graphics Processing Unit card using parallel programming. The system's performance using textural, morphological, architectural and ordinal information was 90.8%, 87.0%, 81.2% and 88.9% respectively. Results indicate that nuclei texture is the most important family of features regarding the degree of malignancy, and, thus, may guide more accurate predictions for discriminating low from high grade gliomas. Considering that nuclei texture is almost impractical to be encoded by visual observation, the need to incorporate computer-aided diagnostic tools as second opinion in daily clinical practice of diagnosing rare brain tumours may be justified.
Varker, Kimberly A; Ansel, Adam; Aukerman, Glen; Carson, William E
2012-01-01
As commonly defined, complementary and alternative medicine (CAM) is a broad category that includes biologically based practices, mind-body medicine, manipulative and bodybased practices, and energy medicine as well as complete medical systems such as naturopathy, homeopathy, Ayurvedic medicine, and traditional Chinese medicine. Several CAM methodologies show promise for the treatment of chronic conditions such as depression and pain disorders or have demonstrated effects upon the immune response in experimental studies. There is growing interest in the use of integrative medicine the combination of CAM methodologies with a conventional medical approach-for the optimization of treatment of various cancers. The Ohio State University Center for Integrative Medicine has developed a specialized nutrigenomic protocol for integrative cancer care. The center uses a comprehensive nutritional and medical evaluation, including a panel of proinflammatory molecules and physiologic parameters, to guide a program of individualized dietary interventions. Dietary supplementation is a current focus of study, including: (1) Omega-3 fatty acids and B vitamins, which are thought to play important roles in immunomodulation; (2) Magnesium oxide, which has been shown to decrease inflammation and improve insulin resistance and lipid profiles; and (3) Cinnamon extract, which reportedly decreases serum glucose levels. This article presents a brief overview of CAM and integrative medicine and a discussion of the relevant nutraceuticals.
Das, Manasi; Duan, Wei; Sahoo, Sanjeeb K
2015-02-01
The promising proposition of multifunctional nanoparticles for cancer diagnostics and therapeutics has inspired the development of theranostic approach for improved cancer therapy. Moreover, active targeting of drug carrier to specific target site is crucial for providing efficient delivery of therapeutics and imaging agents. In this regard, the present study investigates the theranostic capabilities of nutlin-3a loaded poly (lactide-co-glycolide) nanoparticles, functionalized with a targeting ligand (EpCAM aptamer) and an imaging agent (quantum dots) for cancer therapy and bioimaging. A wide spectrum of in vitro analysis (cellular uptake study, cytotoxicity assay, cell cycle and apoptosis analysis, apoptosis associated proteins study) revealed superior therapeutic potentiality of targeted NPs over other formulations in EpCAM expressing cells. Moreover, our nanotheranostic system served as a superlative bio-imaging modality both in 2D monolayer culture and tumor spheroid model. Our result suggests that, these aptamer-guided multifunctional NPs may act as indispensable nanotheranostic approach toward cancer therapy. This study investigated the theranostic capabilities of nutlin-3a loaded poly (lactide-co-glycolide) nanoparticles functionalized with a targeting ligand (EpCAM aptamer) and an imaging agent (quantum dots) for cancer therapy and bioimaging. It was concluded that the studied multifunctional targeted nanoparticle may become a viable and efficient approach in cancer therapy. Copyright © 2015 Elsevier Inc. All rights reserved.
The application of CAD / CAM technology in Dentistry
NASA Astrophysics Data System (ADS)
Susic, I.; Travar, M.; Susic, M.
2017-05-01
Information and communication technologies have found their application in the healthcare sector, including the frameworks of modern dentistry. CAD / CAM application in dentistry is the process by which is attained finished dental restoration through fine milling process of ready ceramic blocks. CAD / CAM is an acronym of english words Computer-Aided-Design (CAD) / Computer-Aided-Manufacture (CAM), respectively dental computer aided design and computer aided manufacture of inlays, onlays, crowns and bridges. CAD / CAM technology essentially allows you to create a two-dimensional and three-dimensional models and their materialization by numerical controlled machines. In order to operate more efficiently, reduce costs, increase user/patient satisfaction and ultimately achieve profits, many dental offices in the world have their attention focused on implementation of modern IT solutions in everyday practice. In addition to the specialized clinic management software, inventory control, etc., or hardware such as the use of lasers in cosmetic dentistry or intraoral scanning, recently the importance is given to the application of CAD / CAM technology in the field of prosthetic. After the removal of pathologically altered tooth structure, it is necessary to achieve restoration that will be most similar to the anatomy of a natural tooth. Applying CAD / CAM technology on applicable ceramic blocks it can be obtained very quick, but also very accurate restoration, in the forms of inlays, onlays, bridges and crowns. The paper presents the advantages of using this technology as well as satisfaction of the patients and dentists by using systems as: Cercon, Celay, Cerec, Lava, Everest, which represent imperative of modern dentistry in creating fixed dental restorations.
Zucuni, C P; Guilardi, L F; Fraga, S; May, L G; Pereira, G K R; Valandro, L F
2017-07-01
This study evaluated the effects of different pre-sintering fabrication processing techniques of Y-TZP ceramic (CAD/CAM Vs. in-lab), considering surface characteristics and mechanical performance outcomes. Pre-sintered discs of Y-TZP ceramic (IPS e.max ZirCAD, Ivoclar Vivadent) were produced using different pre-sintering fabrication processing techniques: Machined- milling with a CAD/CAM system; Polished- fabrication using a cutting device followed by polishing (600 and 1200 SiC papers); Xfine- fabrication using a cutting machine followed by grinding with extra-fine diamond bur (grit size 30 μm); Fine- fabrication using a cutting machine followed by grinding with fine diamond bur (grit size 46 μm); SiC- fabrication using a cutting machine followed by grinding with 220 SiC paper. Afterwards, the discs were sintered and submitted to roughness (n=35), surface topography (n=2), phase transformation (n=2), biaxial flexural strength (n=20), and biaxial flexural fatigue strength (fatigue limit) (n=15) analyses. No monoclinic-phase content was observed in all processing techniques. It can be observed that obtaining a surface with similar characteristics to CAD/CAM milling is essential for the observation of similar mechanical performance. On this sense, grinding with fine diamond bur before sintering (Fine group) was the best mimic protocol in comparison to the CAD/CAM milling. Copyright © 2017 Elsevier Ltd. All rights reserved.
2013-01-01
Introduction The Epithelial Cell Adhesion Molecule (EpCAM) has been shown to be strongly expressed in human breast cancer and cancer stem cells and its overexpression has been supposed to support tumor progression and metastasis. However, effects of EpCAM overexpression on normal breast epithelial cells have never been studied before. Therefore, we analyzed effects of transient adenoviral overexpression of EpCAM on proliferation, migration and differentiation of primary human mammary epithelial cells (HMECs). Methods HMECs were transfected by an adenoviral system for transient overexpression of EpCAM. Thereafter, changes in cell proliferation and migration were studied using a real time measurement system. Target gene expression was evaluated by transcriptome analysis in proliferating and polarized HMEC cultures. A Chicken Chorioallantoic Membrane (CAM) xenograft model was used to study effects on in vivo growth of HMECs. Results EpCAM overexpression in HMECs did not significantly alter gene expression profile of proliferating or growth arrested cells. Proliferating HMECs displayed predominantly glycosylated EpCAM isoforms and were inhibited in cell proliferation and migration by upregulation of p27KIP1 and p53. HMECs with overexpression of EpCAM showed a down regulation of E-cadherin. Moreover, cells were more resistant to TGF-β1 induced growth arrest and maintained longer capacities to proliferate in vitro. EpCAM overexpressing HMECs xenografts in chicken embryos showed hyperplastic growth, lack of lumen formation and increased infiltrates of the chicken leukocytes. Conclusions EpCAM revealed oncogenic features in normal human breast cells by inducing resistance to TGF-β1-mediated growth arrest and supporting a cell phenotype with longer proliferative capacities in vitro. EpCAM overexpression resulted in hyperplastic growth in vivo. Thus, we suggest that EpCAM acts as a prosurvival factor counteracting terminal differentiation processes in normal mammary glands. PMID:23758908
Takeuchi, Hikaru; Taki, Yasuyuki; Nouchi, Rui; Sekiguchi, Atsushi; Kotozaki, Yuka; Miyauchi, Carlos Makoto; Yokoyama, Ryoichi; Iizuka, Kunio; Hashizume, Hiroshi; Nakagawa, Seishu; Kunitoki, Keiko; Sassa, Yuko; Kawashima, Ryuta
2014-01-01
Achievement motivation can be defined as a recurrent need to improve one's past performance. Despite previous functional imaging studies on motivation-related functional activation, the relationship between regional gray matter (rGM) morphology and achievement motivation has never been investigated. We used voxel-based morphometry and a questionnaire (achievement motivation scale) to measure individual achievement motivation and investigated the association between rGM density (rGMD) and achievement motivation [self-fulfillment achievement motivation (SFAM) and competitive achievement motivation (CAM) across the brain in healthy young adults (age 21.0 ± 1.8 years, men (n = 94), women (n = 91)]. SFAM and rGMD significantly and negatively correlated in the orbitofrontal cortex (OFC). CAM and rGMD significantly and positively correlated in the right putamen, insula, and precuneus. These results suggest that the brain areas that play central roles in externally modulated motivation (OFC and putamen) also contribute to SFAM and CAM, respectively, but in different ways. Furthermore, the brain areas in which rGMD correlated with CAM are related to cognitive processes associated with distressing emotions and social cognition, and these cognitive processes may characterize CAM.
Minimally invasive corticotomy in orthodontics: a new technique using a CAD/CAM surgical template.
Cassetta, M; Pandolfi, S; Giansanti, M
2015-07-01
Accelerating orthodontic tooth movement is a topical issue. Despite the different techniques described in the literature, the corticotomy is the only effective and safe means of accelerating orthodontic tooth movement. Although effective, the corticotomy presents significant postoperative discomfort. The aggressive nature of these particular methods, related to the elevation of mucoperiosteal flaps and to the length of the surgery, has resulted in reluctance to proceed with this technique among both patients and the dental community. To overcome the disadvantages of the corticotomy, this technical note describes an innovative, minimally invasive, flapless procedure combining piezoelectric surgical cortical micro-incisions with the use of a 3D Printed CAD/CAM surgical guide. Copyright © 2015 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Tarsitano, Achille; Battaglia, Salvatore; Crimi, Salvatore; Ciocca, Leonardo; Scotti, Roberto; Marchetti, Claudio
2016-07-01
The design and manufacture of patient-specific mandibular reconstruction plates, particularly in combination with cutting guides, has created many new opportunities for the planning and implementation of mandibular reconstruction. Although this surgical method is being used more widely and the outcomes appear to be improved, the question of the additional cost has to be discussed. To evaluate the cost generated by the management of this technology, we studied a cohort of patients treated for mandibular neoplasms. The population was divided into two groups of 20 patients each who were undergoing a 'traditional' freehand mandibular reconstruction or a computer-aided design/computer-aided manufacturing (CAD-CAM) mandibular reconstruction. Data concerning operation time, complications, and days of hospitalisation were used to evaluate costs related to the management of these patients. The mean operating time for the CAD-CAM group was 435 min, whereas that for the freehand group was 550.5 min. The total difference in terms of average time gain was 115.5 min. No microvascular complication occurred in the CAD-CAM group; two complications (10%) were observed in patients undergoing freehand reconstructions. The mean overall lengths of hospital stay were 13.8 days for the CAD-CAM group and 17 days for the freehand group. Finally, considering that the institutional cost per minute of theatre time is €30, the money saved as a result of the time gained was €3,450. This cost corresponds approximately to the total price of the CAD-CAM surgery. In conclusion, we believe that CAD-CAM technology for mandibular reconstruction will become a widely used reconstructive method and that its cost will be covered by gains in terms of surgical time, quality of reconstruction, and reduced complications. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Kang, Hye-Won; Lee, Du-Hyeong
2015-09-01
The existing techniques for drilling a screw access hole in cement-retained restorations are limited by inaccurate drill guidance and ineffective cooling of the drilling area. An approach for fabricating a guide template to provide screw retrievability using computer-aided design and computer-aided manufacturing (CAD/CAM) is described. A handpiece sleeve was made by 3-dimensional printing and incorporating it into a vacuum-formed template. The handpiece sleeve not only guides the head of the handpiece accurately but also enables the cooling water to reach the area of drilling directly. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Salamonsen, Anita
2013-03-01
Cancer patients' use of complementary and alternative medicine (CAM) is widespread, despite the fact that clinical studies validating the efficacy of CAM remain sparse in the Nordic countries. The purpose of this study was to explore possible connections between cancer patients' communication experiences with doctors and the decision to use CAM as either supplement or alternative to conventional treatment (CT). The Regional Committee for Medical and Health Research Ethics and the Norwegian Data Inspectorate approved the study. From a group of 52 cancer patients with self-reported positive experiences from use of CAM, 13 were selected for qualitative interviews. Six used CAM as supplement, and seven as alternative to CT, periodically or permanently. Communication experiences with 46 doctors were described. The analysis revealed three connections between doctor-patient communication and patients' treatment decisions: (i) negative communication experiences because of the use of CAM; (ii) negative communication experiences resulted in the decision to use CAM, and in some cases to decline CT; and (iii) positive communication experiences led to the decision to use CAM as supplement, not alternative to CT. The patients, including the decliners of CT, wanted to discuss treatment decisions in well-functioning interpersonal processes with supportive doctors. In doctors' practices and education of doctors, a greater awareness of potential positive and negative outcomes of doctor-patient communication that concern CAM issues could be of importance. More research is needed to safeguard CAM users' treatment decisions and their relationship to conventional health care. © 2012 The Author. Scandinavian Journal of Caring Sciences © 2012 Nordic College of Caring Science.
Comparison of Swiss basic health insurance costs of complementary and conventional medicine.
Studer, Hans-Peter; Busato, André
2011-01-01
From 1999 to 2005, 5 methods of complementary and alternative medicine (CAM) applied by physicians were provisionally included into mandatory Swiss basic health insurance. Between 2012 and 2017, this will be the case again. Within this process, an evaluation of cost-effectiveness is required. The goal of this study is to compare practice costs of physicians applying CAM with those of physicians applying solely conventional medicine (COM). The study was designed as a cross-sectional investigation of claims data of mandatory health insurance. For the years 2002 and 2003, practice costs of 562 primary care physicians with and without a certificate for CAM were analyzed and compared with patient-reported outcomes. Linear models were used to obtain estimates of practice costs controlling for different patient populations and structural characteristics of practices across CAM and COM. Statistical procedures show similar total practice costs for CAM and COM, with the exception of homeopathy with 15.4% lower costs than COM. Furthermore, there were significant differences between CAM and COM in cost structure especially for the ratio between costs for consultations and costs for medication at the expense of basic health insurance. Patients reported better quality of the patient-physician relationship and fewer adverse side effects in CAM; higher cost-effectiveness for CAM can be deduced from this perspective. This study uses a health system perspective and demonstrates at least equal or better cost-effectiveness of CAM in the setting of Swiss ambulatory care. CAM can therefore be seen as a valid complement to COM within Swiss health care. Copyright © 2011 S. Karger AG, Basel.
Fabricating CAD/CAM Implant-Retained Mandibular Bar Overdentures: A Clinical and Technical Overview.
Goo, Chui Ling; Tan, Keson Beng Choon
2017-01-01
This report describes the clinical and technical aspects in the oral rehabilitation of an edentulous patient with knife-edge ridge at the mandibular anterior edentulous region, using implant-retained overdentures. The application of computer-aided design and computer-aided manufacturing (CAD/CAM) in the fabrication of the overdenture framework simplifies the laboratory process of the implant prostheses. The Nobel Procera CAD/CAM System was utilised to produce a lightweight titanium overdenture bar with locator attachments. It is proposed that the digital workflow of CAD/CAM milled implant overdenture bar allows us to avoid numerous technical steps and possibility of casting errors involved in the conventional casting of such bars.
Activation of EGF receptor kinase by L1-mediated homophilic cell interactions.
Islam, Rafique; Kristiansen, Lars V; Romani, Susana; Garcia-Alonso, Luis; Hortsch, Michael
2004-04-01
Neural cell adhesion molecules (CAMs) are important players during neurogenesis and neurite outgrowth as well as axonal fasciculation and pathfinding. Some of these developmental processes entail the activation of cellular signaling cascades. Pharmacological and genetic evidence indicates that the neurite outgrowth-promoting activity of L1-type CAMs is at least in part mediated by the stimulation of neuronal receptor tyrosine kinases (RTKs), especially FGF and EGF receptors. It has long been suspected that neural CAMs might physically interact with RTKs, but their activation by specific cell adhesion events has not been directly demonstrated. Here we report that gain-of-function conditions of the Drosophila L1-type CAM Neuroglian result in profound sensory axon pathfinding defects in the developing Drosophila wing. This phenotype can be suppressed by decreasing the normal gene dosage of the Drosophila EGF receptor gene. Furthermore, in Drosophila S2 cells, cell adhesion mediated by human L1-CAM results in the specific activation of human EGF tyrosine kinase at cell contact sites and EGF receptors engage in a physical interaction with L1-CAM molecules. Thus L1-type CAMs are able to promote the adhesion-dependent activation of EGF receptor signaling in vitro and in vivo.
Fowler, C Andrew; Núñez Hernandez, Maria F; O'Donnell, Susan E; Yu, Liping; Shea, Madeline A
2017-10-01
Calcineurin (CaN) is a heterodimeric and highly conserved serine/threonine phosphatase (PP2B) that plays a critical role in coupling calcium signals to physiological processes including embryonic cardiac development, NF-AT-regulated gene expression in immune responses, and apoptosis. The catalytic subunit (CaN A ) has three isoforms (α, β, and γ,) in humans and seven isoforms in Paramecium. In all eukaryotes, the EF-hand protein calmodulin (CaM) regulates CaN activity in a calcium-dependent manner. The N- and C-domains of CaM (CaM N and CaM C ) recognize a CaM-binding domain (CaMBD) within an intrinsically disordered region of CaN A that precedes the auto-inhibitory domain (AID) of CaN A . Here we present nearly complete 1 H, 13 C, and 15 N resonance assignments of (Ca 2+ ) 4 -CaM bound to a peptide containing the CaMBD sequence in the beta isoform of CaN A (βCaN A -CaMBDp). Its secondary structure elements predicted from the assigned chemical shifts were in good agreement with those observed in the high-resolution structures of (Ca 2+ ) 4 -CaM bound to CaMBDs of multiple enzymes. Based on the reported literature, the CaMBD of the α isoform of CaN A can bind to CaM in two opposing orientations which may influence the regulatory function of CaM. Because a high resolution structure of (Ca 2+ ) 4 -CaM bound to βCaN A -CaMBDp has not been reported, our studies serve as a starting point for determining the solution structure of this complex. This will demonstrate the preferred orientation of (Ca 2+ ) 4 -CaM on the CaMBD as well as the orientations of CaM N and CaM C relative to each other and to the AID of βCaN A .
Simulations of arctic mixed-phase clouds in forecasts with CAM3 and AM2 for M-PACE
Xie, Shaocheng; Boyle, James; Klein, Stephen A.; ...
2008-02-27
[1] Simulations of mixed-phase clouds in forecasts with the NCAR Atmosphere Model version 3 (CAM3) and the GFDL Atmospheric Model version 2 (AM2) for the Mixed-Phase Arctic Cloud Experiment (M-PACE) are performed using analysis data from numerical weather prediction centers. CAM3 significantly underestimates the observed boundary layer mixed-phase cloud fraction and cannot realistically simulate the variations of liquid water fraction with temperature and cloud height due to its oversimplified cloud microphysical scheme. In contrast, AM2 reasonably reproduces the observed boundary layer cloud fraction while its clouds contain much less cloud condensate than CAM3 and the observations. The simulation of themore » boundary layer mixed-phase clouds and their microphysical properties is considerably improved in CAM3 when a new physically based cloud microphysical scheme is used (CAM3LIU). The new scheme also leads to an improved simulation of the surface and top of the atmosphere longwave radiative fluxes. Sensitivity tests show that these results are not sensitive to the analysis data used for model initialization. Increasing model horizontal resolution helps capture the subgrid-scale features in Arctic frontal clouds but does not help improve the simulation of the single-layer boundary layer clouds. AM2 simulated cloud fraction and LWP are sensitive to the change in cloud ice number concentrations used in the Wegener-Bergeron-Findeisen process while CAM3LIU only shows moderate sensitivity in its cloud fields to this change. Furthermore, this paper shows that the Wegener-Bergeron-Findeisen process is important for these models to correctly simulate the observed features of mixed-phase clouds.« less
Simulations of Arctic mixed-phase clouds in forecasts with CAM3 and AM2 for M-PACE
NASA Astrophysics Data System (ADS)
Xie, Shaocheng; Boyle, James; Klein, Stephen A.; Liu, Xiaohong; Ghan, Steven
2008-02-01
Simulations of mixed-phase clouds in forecasts with the NCAR Atmosphere Model version 3 (CAM3) and the GFDL Atmospheric Model version 2 (AM2) for the Mixed-Phase Arctic Cloud Experiment (M-PACE) are performed using analysis data from numerical weather prediction centers. CAM3 significantly underestimates the observed boundary layer mixed-phase cloud fraction and cannot realistically simulate the variations of liquid water fraction with temperature and cloud height due to its oversimplified cloud microphysical scheme. In contrast, AM2 reasonably reproduces the observed boundary layer cloud fraction while its clouds contain much less cloud condensate than CAM3 and the observations. The simulation of the boundary layer mixed-phase clouds and their microphysical properties is considerably improved in CAM3 when a new physically based cloud microphysical scheme is used (CAM3LIU). The new scheme also leads to an improved simulation of the surface and top of the atmosphere longwave radiative fluxes. Sensitivity tests show that these results are not sensitive to the analysis data used for model initialization. Increasing model horizontal resolution helps capture the subgrid-scale features in Arctic frontal clouds but does not help improve the simulation of the single-layer boundary layer clouds. AM2 simulated cloud fraction and LWP are sensitive to the change in cloud ice number concentrations used in the Wegener-Bergeron-Findeisen process while CAM3LIU only shows moderate sensitivity in its cloud fields to this change. This paper shows that the Wegener-Bergeron-Findeisen process is important for these models to correctly simulate the observed features of mixed-phase clouds.
Aragón, C; Carvalho, L; González, J; Escalona, M; Amancio, S
2012-04-01
Many plant species grown under in vitro controlled conditions can be used as models for the study of physiological processes. Adult pineapple can display CAM physiology while in vitro it functions as a C3 plant. Ex vitro Ananas comosus has plastic morphology and physiology, both easy to modify from C3 to CAM by changing the environmental conditions. The yield of survival for a rentable propagation protocol of pineapple is closely related with the C3/CAM shift and the associated physiological characteristics. In the present work, ex vitro pineapple plants were divided in two sets and subjected to C3 and CAM-inducing environmental conditions, determined by light intensity and relative humidity, respectively, 40 μmol m(-2) s(-1)/85% and 260 μmol m(-2) s(-1)/50%. The results demonstrated that the stress imposed by the environmental conditions switched pineapple plants from C3 to CAM behavior. Comparing to CAM induced, C3-induced pineapple plants showed substandard growth parameters and morphological leaf characteristics but a better rooting process and a higher ABA production, a phenotype closer to adult plants, which are expected to produce fruits in a normal production cycle. We conclude that the upholding of these characteristics is conditioned by low light intensity plus high relative humidity, especially during the first 8 weeks of ex vitro growth. It is expected that the better understanding of pineapple acclimatization will contribute to the design of a protocol to apply as a rentable tool in the pineapple agronomic industry. © Springer-Verlag 2011
From Artisanal to CAD-CAM Blocks: State of the Art of Indirect Composites.
Mainjot, A K; Dupont, N M; Oudkerk, J C; Dewael, T Y; Sadoun, M J
2016-05-01
Indirect composites have been undergoing an impressive evolution over the last few years. Specifically, recent developments in computer-aided design-computer-aided manufacturing (CAD-CAM) blocks have been associated with new polymerization modes, innovative microstructures, and different compositions. All these recent breakthroughs have introduced important gaps among the properties of the different materials. This critical state-of-the-art review analyzes the strengths and weaknesses of the different varieties of CAD-CAM composite materials, especially as compared with direct and artisanal indirect composites. Indeed, new polymerization modes used for CAD-CAM blocks-especially high temperature (HT) and, most of all, high temperature-high pressure (HT-HP)-are shown to significantly increase the degree of conversion in comparison with light-cured composites. Industrial processes also allow for the augmentation of the filler content and for the realization of more homogeneous structures with fewer flaws. In addition, due to their increased degree of conversion and their different monomer composition, some CAD-CAM blocks are more advantageous in terms of toxicity and monomer release. Finally, materials with a polymer-infiltrated ceramic network (PICN) microstructure exhibit higher flexural strength and a more favorable elasticity modulus than materials with a dispersed filler microstructure. Consequently, some high-performance composite CAD-CAM blocks-particularly experimental PICNs-can now rival glass-ceramics, such as lithium-disilicate glass-ceramics, for use as bonded partial restorations and crowns on natural teeth and implants. Being able to be manufactured in very low thicknesses, they offer the possibility of developing innovative minimally invasive treatment strategies, such as "no prep" treatment of worn dentition. Current issues are related to the study of bonding and wear properties of the different varieties of CAD-CAM composites. There is also a crucial need to conduct clinical studies. Last, manufacturers should provide more complete information regarding their product polymerization process, microstructure, and composition, which significantly influence CAD-CAM material properties. © International & American Associations for Dental Research 2016.
Using Metadynamics to Understand the Mechanism of Calmodulin/Target Recognition at Atomic Detail
Fiorin, G.; Pastore, A.; Carloni, P.; Parrinello, M.
2006-01-01
The ability of calcium-bound calmodulin (CaM) to recognize most of its target peptides is caused by its binding to two hydrophobic residues (‘anchors’). In most of the CaM complexes, the anchors pack against the hydrophobic pockets of the CaM domains and are surrounded by fully conserved Met side chains. Here, by using metadynamics simulations, we investigate quantitatively the energetics of the final step of this process using the M13 peptide, which has a high affinity and spans the sequence of the skeletal myosin light chain kinase, an important natural CaM target. We established the accuracy of our calculations by a comparison between calculated and NMR-derived structural and dynamical properties. Our calculations provide novel insights into the mechanism of protein/peptide recognition: we show that the process is associated with a free energy gain similar to that experimentally measured for the CaM complex with the homologous smooth muscle MLCK peptide (Ehrhardt et al., 1995, Biochemistry 34, 2731). We suggest that binding is dominated by the entropic effect, in agreement with previous proposals. Furthermore, we explain the role of conserved methionines by showing that the large flexibility of these side chains is a key feature of the binding mechanism. Finally, we provide a rationale for the experimental observation that in all CaM complexes the C-terminal domain seems to be hierarchically more important in establishing the interaction. PMID:16877506
CO2 Acquisition Membrane (CAM) Project
NASA Technical Reports Server (NTRS)
Mason, Larry W.
2003-01-01
The CO2 Acquisition Membrane (CAM) project was performed to develop, test, and analyze thin film membrane materials for separation and purification of carbon dioxide (CO2) from mixtures of gases, such as those found in the Martian atmosphere. The membranes developed in this project are targeted toward In Situ Resource Utilization (ISRU) applications, such as In Situ Propellant Production (ISPP) and In Situ Consumables Production (ISCP). These membrane materials may be used in a variety of ISRU systems, for example as the atmospheric inlet filter for an ISPP process to enhance the concentration of CO2 for use as a reactant gas, to passively separate argon and nitrogen trace gases from CO2 for habitat pressurization, to provide a system for removal of CO2 from breathing gases in a closed environment, or within a process stream to selectively separate CO2 from other gaseous components. The membranes identified and developed for CAM were evaluated for use in candidate ISRU processes and other gas separation applications, and will help to lay the foundation for future unmanned sample return and human space missions. CAM is a cooperative project split among three institutions: Lockheed Martin Astronautics (LMA), the Colorado School of Mines (CSM), and Marshall Space Flight Center (MSFC).
Kim, Jae-Hong; Oh, Seunghan; Uhm, Soo-Hyuk
2016-01-01
The aim of this study is to quantify the effect of the crystallization process on lithium disilicate ceramic crowns fabricated using a computer-aided design/computer-aided manufacturing (CAD/CAM) system and to determine whether the effect of crystallization is clinically acceptable by comparing values of fit before and after the crystallization process. The mandibular right first molar was selected as the abutment for the experiments. Fifteen working models were prepared. Lithium disilicate crowns appropriate for each abutment were prepared using a commercial CAD/CAM system. Gaps in the marginal area and 4 internal areas of each crown were measured twice-before and after crystallization-using the silicone replica technique. The mean values of fit before and after crystallization were analyzed using a paired t-test to examine whether the conversion that occurred during crystallization affected marginal and internal gaps (α = 0.05). Gaps increased in the marginal area and decreased in the internal areas after crystallization. There were statistically significant differences in all of the investigated areas (P < 0.05). None of the values for marginal and internal fit of lithium disilicate CAD/CAM crowns after crystallization exceeded 120 μm, which is the clinically acceptable threshold.
Grip and slip of L1-CAM on adhesive substrates direct growth cone haptotaxis
Abe, Kouki; Katsuno, Hiroko; Toriyama, Michinori; Baba, Kentarou; Mori, Tomoyuki; Hakoshima, Toshio; Kanemura, Yonehiro; Watanabe, Rikiya; Inagaki, Naoyuki
2018-01-01
Chemical cues presented on the adhesive substrate direct cell migration, a process termed haptotaxis. To migrate, cells must generate traction forces upon the substrate. However, how cells probe substrate-bound cues and generate directional forces for migration remains unclear. Here, we show that the cell adhesion molecule (CAM) L1-CAM is involved in laminin-induced haptotaxis of axonal growth cones. L1-CAM underwent grip and slip on the substrate. The ratio of the grip state was higher on laminin than on the control substrate polylysine; this was accompanied by an increase in the traction force upon laminin. Our data suggest that the directional force for laminin-induced growth cone haptotaxis is generated by the grip and slip of L1-CAM on the substrates, which occur asymmetrically under the growth cone. This mechanism is distinct from the conventional cell signaling models for directional cell migration. We further show that this mechanism is disrupted in a human patient with L1-CAM syndrome, suffering corpus callosum agenesis and corticospinal tract hypoplasia. PMID:29483251
Cell adhesion molecules in context
2011-01-01
Cell adhesion molecules (CAMs) are now known to mediate much more than adhesion between cells and between cells and the extracellular matrix. Work by many researchers has illuminated their roles in modulating activation of molecules such as receptor tyrosine kinases, with subsequent effects on cell survival, migration and process extension. CAMs are also known to serve as substrates for proteases that can create diffusible fragments capable of signaling independently from the CAM. The diversity of interactions is further modulated by membrane rafts, which can co-localize or separate potential signaling partners to affect the likelihood of a given signaling pathway being activated. Given the ever-growing number of known CAMs and the fact that their heterophilic binding in cis or in trans can affect their interactions with other molecules, including membrane-bound receptors, one would predict a wide range of effects attributable to a particular CAM in a particular cell at a particular stage of development. The function(s) of a given CAM must therefore be considered in the context of the history of the cell expressing it and the repertoire of molecules expressed both by that cell and its neighbors. PMID:20948304
Optical properties of current ceramics systems for laminate veneers.
Bagis, Bora; Turgut, Sedanur
2013-08-01
Full-ceramic systems can be produced by different techniques (layering, heatpressing, CAD/CAM) and have various compositions with different crystalline contents that may affect the optical properties of laminate restorations. A total of 60 specimens were prepared from e.max Press, e.max CAD, Empress Esthetic, e.max Ceram, Inline, and ZirPress systems (A1 shade; diameter 10mm; thickness 0.5 ± 0.05mm). The L*, a*, and b* values, chroma and translucency (TP) of each system were recorded before and after ageing. The statistical analyses were performed by ANOVA, Tukey's tests and the paired sample t-test (p<0.05). The L* value of the shade guide was significantly different from those of the full-ceramic systems; however, there were no significant differences between the a* values of Ceram, Esthetic, Inline and Zirpress. There were significant differences between the b* values of the shade guide compared with the full-ceramics except for e.max Press. The L* values decreased, and the a* and b* values increased after the ageing process for all groups. There were no significant differences between the ΔE values of the ceramic systems (p>0.05). The TP values decreased, and the chroma value increased significantly after the ageing process (p>0.05). The chroma of the shade guide was found to be the highest. None of the full-ceramic systems was able to match the color of the shade guide. The chemical structures of the ceramic systems were more effective for determining the optical parameters than the fabrication techniques. Ageing caused full-ceramics to become more opaque, darker, reddish and yellowish. Copyright © 2012 Elsevier Ltd. All rights reserved.
Haider, Muhammad Sajjad; Barnes, Jeremy D.; Cushman, John C.; Borland, Anne M.
2012-01-01
In the halophytic species Mesembryanthemum crystallinum, the induction of crassulacean acid metabolism (CAM) by salinity requires a substantial investment of resources in storage carbohydrates to provide substrate for nocturnal CO2 uptake. Acclimation to salinity also requires the synthesis and accumulation of cyclitols as compatible solutes, maintenance of root respiration, and nitrate assimilation. This study assessed the hierarchy and coordination of sinks for carbohydrate in leaves and roots during acclimation to salinity in M. crystallinum. By comparing wild type and a CAM-/starch-deficient mutant of this species, it was sought to determine if other metabolic sinks could compensate for a curtailment in CAM and enable acclimation to salinity. Under salinity, CAM deficiency reduced 24 h photosynthetic carbon gain by >50%. Cyclitols were accumulated to comparable levels in leaves and roots of both the wild type and mutant, but represented only 5% of 24 h carbon balance. Dark respiration of leaves and roots was a stronger sink for carbohydrate in the mutant compared with the wild type and implied higher maintenance costs for the metabolic processes underpinning acclimation to salinity when CAM was curtailed. CAM required the nocturnal mobilization of >70% of primary carbohydrate in the wild type and >85% of carbohydrate in the mutant. The substantial allocation of carbohydrate to CAM limited the export of sugars to roots, and the root:shoot ratio declined under salinity. The data suggest a key role for the vacuole in regulating the supply and demand for carbohydrate over the day/night cycle in the starch-/CAM-deficient mutant. PMID:22219316
Characterization of Novel Calmodulin Binding Domains within IQ Motifs of IQGAP1
Jang, Deok-Jin; Ban, Byungkwan; Lee, Jin-A
2011-01-01
IQ motif-containing GTPase-activating protein 1 (IQGAP1), which is a well-known calmodulin (CaM) binding protein, is involved in a wide range of cellular processes including cell proliferation, tumorigenesis, adhesion, and migration. Interaction of IQGAP1 with CaM is important for its cellular functions. Although each IQ domain of IQGAP1 for CaM binding has been characterized in a Ca2+-dependent or -independent manner, it was not clear which IQ motifs are physiologically relevant for CaM binding in the cells. In this study, we performed immunoprecipitation using 3xFLAGhCaM in mammalian cell lines to characterize the domains of IQGAP1 that are key for CaM binding under physiological conditions. Interestingly, using this method, we identified two novel domains, IQ(2.7-3) and IQ(3.5-4.4), within IQGAP1 that were involved in Ca2+-independent or -dependent CaM binding, respectively. Mutant analysis clearly showed that the hydrophobic regions within IQ(2.7-3) were mainly involved in apoCaM binding, while the basic amino acids and hydrophobic region of IQ(3.5-4.4) were required for Ca2+/CaM binding. Finally, we showed that IQ(2.7-3) was the main apoCaM binding domain and both IQ(2.7-3) and IQ(3.5-4.4) were required for Ca2+/CaM binding within IQ(1- 2-3-4). Thus, we identified and characterized novel direct CaM binding motifs essential for IQGAP1. This finding indicates that IQGAP1 plays a dynamic role via direct interactions with CaM in a Ca2+-dependent or -independent manner. PMID:22080369
UK: the current state of regulation of complementary and alternative medicine.
Walker, L A; Budd, S
2002-03-01
There is no legislation that restricts the practice of CAM in the UK apart from the practice of chiropractic and osteopathy and limits on advertising the treatments of certain conditions such as cancer and tuberculosis. The UK government has increasingly recognised the need for comprehensive regulation of CAM, though it abandoned its original plan for a single overarching regulatory body. Initiatives to examine and hasten the process of regulation have included setting up a central, well-recognised charitable body to facilitate progress for individual professions, and an authoritative survey of the existing professional organisations. One pathway open to individual professions is statutory self-regulation, which requires a single governing body, a systematic corpus of knowledge, recognised training courses and demonstrated efficacy. The other pathway is voluntary self-regulation. Chiropractic and osteopathy have adopted statutory self-regulation, though this has proved expensive for individual members of these professions. A recent House of Lords report on CAM has recommended that the herbal medicine and acupuncture professions should also develop a system of statutory regulation. Other professions, such as aromatherapy, are in the process of establishing single professional bodies as a first step towards self-regulation. Among the issues that remain to be resolved is the relationship between the CAM professions and statutory registered practitioners who also practise CAM.
2016-10-19
This image of the sunlit part of Jupiter and its swirling atmosphere was created by a citizen scientist (Alex Mai) using data from Juno's JunoCam instrument. JunoCam's raw images are available at www.missionjuno.swri.edu/junocam for the public to peruse and process into image products. http://photojournal.jpl.nasa.gov/catalog/PIA21108
Myung, Ja Hye; Launiere, Cari A; Eddington, David T; Hong, Seungpyo
2010-06-01
The selective detection of circulating tumor cells (CTCs) is of significant clinical importance for the clinical diagnosis and prognosis of cancer metastasis. However, largely because of the extremely low number of CTCs (as low as 1 in 10(9) hematologic cells) in the blood of patients, effective detection and separation of the rare cells remain a tremendous challenge. Cell rolling is known to play a key role in physiological processes such as the recruitment of leukocytes to sites of inflammation and selectin-mediated CTC metastasis. Furthermore, because CTCs typically express the epithelial-cell adhesion molecule (EpCAM) on the surface whereas normal hematologic cells do not, substrates with immobilized antibody against EpCAM may specifically interact with CTCs. In this article, we created biomimetic surfaces functionalized with P- and E-selectin and anti-EpCAM that induce different responses in HL-60 (used as a model of leukocytes in this study) and MCF-7 (a model of CTCs) cells. HL-60 and MCF-7 cells showed different degrees of interaction with P-/E-selectin and anti-EpCAM at a shear stress of 0.32 dyn/cm(2). HL-60 cells exhibited rolling on P-selectin-immobilized substrates at a velocity of 2.26 +/- 0.28 microm/s whereas MCF-7 cells had no interaction with the surface. Both cell lines, however, had interactions with E-selectin, and the rolling velocity of MCF-7 cells (4.24 +/- 0.31 microm/s) was faster than that of HL-60 cells (2.12 +/- 0.15 microm/s). However, only MCF-7 cells interacted with anti-EpCAM-coated surfaces, forming stationary binding under flow. More importantly, the combination of the rolling (E-selectin) and stationary binding (anti-EpCAM) resulted in substantially enhanced separation capacity and capture efficiency (more than 3-fold enhancement), as compared to a surface functionalized solely with anti-EpCAM that has been commonly used for CTC capture. Our results indicate that cell-specific detection and separation may be achieved through mimicking the biological processes of combined dynamic cell rolling and stationary binding, which will likely lead to a CTC detection device with significantly enhanced specificity and sensitivity without a complex fabrication process.
Chanques, Gérald; Garnier, Océane; Carr, Julie; Conseil, Matthieu; de Jong, Audrey; Rowan, Christine M; Ely, E Wesley; Jaber, Samir
2017-10-01
Delirium is common in Intensive-Care-Unit (ICU) patients but under-recognized by bed-side clinicians when not using validated delirium-screening tools. The Confusion-Assessment-Method for the ICU (CAM-ICU) has demonstrated very good psychometric properties, and has been translated into many different languages though not into French. We undertook this opportunity to describe the translation process. The translation was performed following recommended guidelines. The updated method published in 2014 including introduction letters, worksheet and flowsheet for bed-side use, the method itself, case-scenarios for training and Frequently-Asked-Questions (32 pages) was translated into French language by a neuropsychological researcher who was not familiar with the original method. Then, the whole method was back-translated by a native English-French bilingual speaker. The new English version was compared to the original one by the Vanderbilt University ICU-delirium-team. Discrepancies were discussed between the two teams before final approval of the French version. The entire process took one year. Among the 3692 words of the back-translated version of the method itself, 18 discrepancies occurred. Eight (44%) lead to changes in the final version. Details of the translation process are provided. The French version of CAM-ICU is now available for French-speaking ICUs. The CAM-ICU is provided with its complete training-manual that was challenging to translate following recommended process. While many such translations have been done for other clinical tools, few have published the details of the process itself. We hope that the availability of such teaching material will now facilitate a large implementation of delirium-screening in French-speaking ICUs. Copyright © 2017 Société française d'anesthésie et de réanimation (Sfar). All rights reserved.
Effect of N-CAM on in vitro invasion of human adenoid cystic carcinoma cells.
França, C M; Jaeger, R G; Freitas, V M; Araújo, N S; Jaeger, M M
2001-12-01
Adenoid cystic carcinoma of salivary glands is characterised by aggressive behaviour, high rate of local recurrences, neurotropism and late metastasis. In a previous work we demonstrated that adenoid cystic carcinoma cultured cells (CAC2 cells) expressed N-CAM. It was suggested that this expression, modulated by extracellular matrix, would be correlated to cell movement. The aim of our study was to verify whether CAC2 cells presented invasion capacity. Moreover, we tested whether the neural adhesion molecule (N-CAM) would participate in this process. CAC2 cells were either previously treated, or not (control), with a monoclonal antibody against N-CAM. Invasion assays were carried out using a modified Boyden chamber (Transwell chamber). CAC2 cells (10(5)) were dispensed into Transwell upper chamber on the top of Matrigel coated filter. The cells that invaded the filters in the first 8 h were counted under light microscopy, yielding data for the invasion rates (%). Control CAC2 cells presented an invasion rate of 5.28+/-0.04%. The invasion rate raised to 6.53+/-0.2% when N-CAM was blocked with monoclonal antibody. N-CAM impaired the adenoid cystic carcinoma cell invasion in vitro. Therefore, we suggest an anti-invasive role for N-CAM in adenoid cystic carcinoma.
Wong, M S; Cheng, C Y; Ng, B K W; Lam, T P; Chiu, S W
2006-01-01
Spinal orthoses are commonly prescribed to patients with moderate AIS for prevention of further deterioration. In a conventional manufacturing method, plaster bandages are used to get patient's body contour and plaster cast is rectified manually. With the introduction of CAD/CAM system, a series of automated processes from body scanning to digital rectification and milling of positive model can be performed in a fast and accurate fashion. This project is to study the impact of CAD/CAM method as compared with the conventional method. In assessing the 147 recruited subjects fitted with spinal orthoses (43 subjects using conventional method and 104 subjects using CAD/CAM method), significant decreases (p<0.05) were found in the Cobb angles when comparing the pre-intervention data with that of the first year of intervention. Regarding the learning curve, Orthotists are getting more competent with the CAD/CAM technique in four years time. The mean productivity of the CAD/CAM method is 2.75 times higher than that of the conventional method. The CAD/CAM method could achieve similar clinical outcomes and with its high efficiency, could be considered as substitute for conventional methods in fabricating spinal orthoses for patients with AIS.
Activation of EGF Receptor Kinase by L1-mediated Homophilic Cell Interactions
Islam, Rafique; Kristiansen, Lars V.; Romani, Susana; Garcia-Alonso, Luis; Hortsch, Michael
2004-01-01
Neural cell adhesion molecules (CAMs) are important players during neurogenesis and neurite outgrowth as well as axonal fasciculation and pathfinding. Some of these developmental processes entail the activation of cellular signaling cascades. Pharmacological and genetic evidence indicates that the neurite outgrowth-promoting activity of L1-type CAMs is at least in part mediated by the stimulation of neuronal receptor tyrosine kinases (RTKs), especially FGF and EGF receptors. It has long been suspected that neural CAMs might physically interact with RTKs, but their activation by specific cell adhesion events has not been directly demonstrated. Here we report that gain-of-function conditions of the Drosophila L1-type CAM Neuroglian result in profound sensory axon pathfinding defects in the developing Drosophila wing. This phenotype can be suppressed by decreasing the normal gene dosage of the Drosophila EGF receptor gene. Furthermore, in Drosophila S2 cells, cell adhesion mediated by human L1-CAM results in the specific activation of human EGF tyrosine kinase at cell contact sites and EGF receptors engage in a physical interaction with L1-CAM molecules. Thus L1-type CAMs are able to promote the adhesion-dependent activation of EGF receptor signaling in vitro and in vivo. PMID:14718570
JunoCam Images of Jupiter: Science from an Outreach Experiment
NASA Astrophysics Data System (ADS)
Hansen, C. J.; Orton, G. S.; Caplinger, M. A.; Ravine, M. A.; Rogers, J.; Eichstädt, G.; Jensen, E.; Bolton, S. J.; Momary, T.; Ingersoll, A. P.
2017-12-01
The Juno mission to Jupiter carries a visible imager on its payload primarily for outreach, and also very useful for jovian atmospheric science. Lacking a formal imaging science team, members of the public have volunteered to process JunoCam images. Lightly processed and raw JunoCam data are posted on the JunoCam webpage at https://missionjuno.swri.edu/junocam/processing. Citizen scientists download these images and upload their processed contributions. JunoCam images through broadband red, green and blue filters and a narrowband methane filter centered at 889 nm mounted directly on the detector. JunoCam is a push-frame imager with a 58 deg wide field of view covering a 1600 pixel width, and builds the second dimension of the image as the spacecraft rotates. This design enables capture of the entire pole of Jupiter in a single image at low emission angle when Juno is 1 hour from perijove (closest approach). At perijove the wide field of view images are high-resolution while still capturing entire storms, e.g. the Great Red Spot. Juno's unique polar orbit yields polar perspectives unavailable to earth-based observers or most previous spacecraft. The first discovery was that the familiar belt-zone structure gives way to more chaotic storms, with cyclones grouped around both the north and south poles [1, 2]. Recent time-lapse sequences have enabled measurement of the rotation rates and wind speeds of these circumpolar cyclones [3]. Other topics are being investigated with substantial, in many cases essential, contributions from citizen scientists. These include correlating the high resolution JunoCam images to storms and disruptions of the belts and zones tracked throughout the historical record. A phase function for Jupiter is being developed empirically to allow image brightness to be flattened from the subsolar point to the terminator. We are studying high hazes and the stratigraphy of the upper atmosphere, utilizing the methane filter, structures illuminated beyond the terminator, and clouds casting shadows. Numerous high altitude clouds have been detected and we are investigating whether they are the jovian equivalent of squall lines. [1] Bolton, S. et al. (2017) Science 356:821; [2] Orton, G. et al. (2017) GRL 44:4599; [3] Adriani, A. et al. (2017) submitted to Nature.
Alao, Abdur-Rasheed; Stoll, Richard; Song, Xiao-Fei; Abbott, John R; Zhang, Yu; Abduo, Jaafar; Yin, Ling
2017-10-01
This paper studied surface fracture, roughness and morphology, phase transformations, and material removal mechanisms of lithium metasilicate/disilicate glass ceramics (LMGC/LDGC) in CAD/CAM-milling and subsequent surface treatments. LMGC (IPS e.max CAD) blocks were milled using a chairside dental CAD/CAM milling unit and then treated in sintering, polishing and glazing processes. X-ray diffraction was performed on all processed surfaces. Scanning electron microscopy (SEM) was applied to analyse surface fracture and morphology. Surface roughness was quantitatively characterized by the arithmetic average surface roughness R a and the maximum roughness R z using desktop SEM-assisted morphology analytical software. The CAD/CAM milling induced extensive brittle cracks and crystal pulverization on LMGC surfaces, which indicate that the dominant removal mechanism was the fracture mode. Polishing and sintering of the milled LMGC lowered the surface roughness (ANOVA, p < 0.05), respectively, while sintering also fully transformed the weak LMGC to the strong LDGC. However, polishing and glazing of LDGC did not significantly improve the roughness (ANOVA, p > 0.05). In comparison of all applied fabrication process routes, it is found that CAD/CAM milling followed by polishing and sintering produced the smoothest surface with R a = 0.12 ± 0.08µm and R z = 0.89 ± 0.26µm. Thus , it is proposed as the optimized process route for LMGC/LDGC in dental restorations. This route enables to manufacture LMGC/LDGC restorations with cost effectiveness, time efficiency, and improved surface quality for better occlusal functions and reduced bacterial plaque accumulation. Copyright © 2017 Elsevier Ltd. All rights reserved.
TONEKABONI, Seyed Hassan; JAFARI NAEINI, Sepideh; KHAJEH, Ali; YAGHINI, Omid; GHAZAVI, Ahad; ABDOLLAH GORJI, Fatemeh
2014-01-01
Objective Although the use of Complementary and Alternative Medicine (CAM) has been evaluated globally, there are few studies in our country on this subject. The purpose of this study was to determine the prevalence, pattern of use, parental sources of information, and benefits of CAM in epileptic children in Tehran. Materials & Methods One hundred thirty-three parents or relatives of epileptic children who were referred to outpatient clinics or admitted in neurologic ward of four major hospitals in Tehran, were interviewed by our researcher based on a structured questionnaire; from 2009 to 2010. The information obtained comprised the demographic data of patients and their parents, frequency and morphology of convulsions, the type and sources of CAM and finally, the benefits and adverse effects of this practice. Results Forty-four percent of the respondents had used CAM methods either alone or in combination with other methods. The most frequently used CAM was written prayers followed by oral herbs and special diets. CAM was mainly introduced to them by relatives. Only 16.7% of these parents had discussed this matter with their children’s physicians. No efficacy to control seizure was observed for most of these methods. Conclusion This study showed that use of CAM in our study group is relatively common and may have a potentially hazardous role in the treatment process. So, it is necessary for physicians to have enough information about CAM practice in their patients. PMID:24665324
Extending ORAC-DR for Offline Processing of ESO, INGRID, and Classic Cam data
NASA Astrophysics Data System (ADS)
Currie, M. J.
2004-07-01
ORAC-DR--a flexible reduction pipeline---was originally developed by the Joint Astronomy Centre for real-time inspection of reduced data at its telescopes. Starlink is extending ORAC-DR to process at home institutions data from other observatories, notably ESO, whose instruments make no provision for ORAC-DR. I outline the problems encountered and solutions implemented or proposed to apply ORAC-DR to the infra-red instruments ISAAC, NACO, INGRID, and Classic~Cam.
Zimmermann, M; Valcanaia, A; Neiva, G; Mehl, A; Fasbinder, D
2018-04-09
CAM fabrication is an important step within the CAD/CAM process. The internal fit of restorations is influenced by the accuracy of the subtractive CAM procedure. Little is known about how CAM strategies might influence the fit of CAD/CAM fabricated restorations. The aim of this study was to three-dimensionally evaluate the fit of CAD/CAM fabricated zirconia-reinforced lithium silicate ceramic partial crowns fabricated with three different CAM strategies. The null hypothesis was that different CAM strategies did not influence the fitting accuracy of CAD/CAM fabricated zirconia-reinforced lithium silicate ceramic partial crowns. Preparation for a partial crown was performed on a maxillary right first molar on a typodont. A chairside CAD/CAM system with the intraoral scanning device CEREC Omnicam (Dentsply Sirona, York, PA, USA) and the 3+1 axis milling unit CEREC MCXL was used. There were three groups with different CAM strategies: step bur 12 (12), step bur 12S (12S), and two step-mode (12TWO). The zirconia-reinforced lithium silicate ceramic Celtra Duo (Dentsply Sirona) was used as the CAD/CAM material. A new 3D method for evaluating the fit was applied, consisting of the quadrant scan with the intraoral scanning device CEREC Omnicam. The scan of the PVS material adherent to the preparation and the preparation scan were matched, and the difference analysis was performed with special software OraCheck (Cyfex AG, Zurich, Switzerland). Three areas were selected for analysis: margin (MA), axial (AX), and occlusal (OC). Statistical analysis was performed using 80% percentile, one-way ANOVA, and the post hoc Scheffé test with α=0.05. Statistically significant differences were found both within and between the test groups. The aspect axial fit results varied from 90.5 ± 20.1 μm for the two-step milling mode (12TWO_AX) to 122.8 ± 12.2 μm for the milling with step bur 12S (12S_AX). The worst result in all groups was found for the aspect occlusal fit with the highest value for group 12S of 222.8 ± 35.6 μm. Group two-step milling mode (12TWO) performed statistically significantly better from groups 12 and 12S for the occlusal fit ( p<0.05). Deviation patterns were visually analyzed with a color-coded scheme for each restoration. CAM strategy influenced the internal adaptation of zirconia-reinforced lithium silicate partial crowns fabricated with a chairside CAD/CAM system. Sensible selection of specific areas of internal adaptation and fit is an important factor for evaluating the CAM accuracy of CAD/CAM systems.
Schmalzigaug, Robert; Ye, Qunrui; Berchtold, Martin W
2001-01-01
Calmodulin (CaM) is the main intracellular Ca2+ sensor protein responsible for mediating Ca2+ triggered processes. Chicken DT40 lymphoma B cells express CaM from the two genes, CaMI and CaMII. Here we report the phenotypes of DT40 cells with the CaMII gene knocked out. The disruption of the CaMII gene causes the intracellular CaM level to decrease by 60%. CaMII−/− cells grow more slowly and die more frequently as compared to wild type (wt) cells but do not exhibit significant differences in their cell cycle profile. Both phenotypes are more pronounced at reduced serum concentrations. Upon stimulation of the B-cell receptor (BCR), the resting Ca2+ levels remain elevated after the initial transient in CaMII−/− cells. Despite higher Ca2+ resting levels, the CaMII−/− cells are partially protected from BCR induced apoptosis indicating that CaM plays a dual role in apoptotic processes. PMID:11454062
Safety Modification of Cam-and-Groove Hose Coupling
NASA Technical Reports Server (NTRS)
Schwindt, Paul; Littlefield, Alan
2008-01-01
A modification has been made in the mating halves of a cam-and-groove hose coupling to prevent rapid separation of the halves in the event that the cam levers are released while the fluid in the hose is pressurized. The need for this modification arises because commercial off-the-shelf cam-and-groove hose-coupling halves do not incorporate safety features to prevent separation in the pressurized state. Especially when the pressurized fluid is compressible (e.g., steam or compressed air), the separated halves can be propelled with considerable energy, causing personal injury and/or property damage. Therefore, one purpose served by the modification is to provide for venting to release compressive energy in a contained and safe manner while preventing personal injury and/or property damage. Another purpose served by the modification, during the process of connecting the coupling halves, is to ensure that the coupling halves are properly aligned before the cam levers can be locked into position.
Analyzing the research in Integrative & Complementary Medicine by means of science mapping.
Moral-Muñoz, J A; Cobo, M J; Peis, E; Arroyo-Morales, M; Herrera-Viedma, E
2014-04-01
The research in the Complementary and Alternative Medicine (CAM) field is analyzed according to the journals indexed in ISI Web of Science. Science Mapping Analysis (SMA) is used to provide and overview of the conceptual evolution of the CAM field. The software SciMAT is used to detect and visualize the hidden themes and their evolution over a consecutive span of years. It combines SMA and performance analysis. Twenty one journals related to CAM were analyzed, in four consecutive periods from 1974 to 2011. Strategic diagrams and the thematic evolution of CAM, together with performance indicators (h-index), were obtained. The results show that CAM research has focused on seven main thematic areas: MEDICINAL-PLANTS, CHIROPRACTIC-AND-LOW-BACK-PAIN, ACUPUNCTURE-AND-PAIN, CELL-PROCESSES-AND-DISEASES, LIPID-PEROXIDATION and DIABETES-AND-INSULIN. The research output could be used by the scientific community to identify thematic areas on which interest is focused. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Zhang, Z.; Song, H.; Wang, M.; Ghan, S. J.; Dong, X.
2016-12-01
he main objective of this study is to systematically evaluate the MBL cloud properties simulated in CAM5 family models using a combination of satellite-based CloudSat/MODIS observations and ground-based observations from the ARM Azores site, with a special focus on MBL cloud microphysics and warm rain process. First, we will present a global evaluation based on satellite observations and retrievals. We will compare global cloud properties (e.g., cloud fraction, cloud vertical structure, cloud CER, COT, and LWP, as well as drizzle frequency and intensity diagnosed using the CAM5-COSP instrumental simulators) simulated in the CAM5 models with the collocated CloudSat and MODIS observations. We will also present some preliminary results from a regional evaluation based mainly on ground observations from ARM Azores site. We will compare MBL cloud properties simulated in CAM5 models over the ARM Azores site with collocated satellite (MODIS and CloudSat) and ground-based observations from the ARM site.
Kim, Jae-Hong; Oh, Seunghan; Uhm, Soo-Hyuk
2016-01-01
The aim of this study is to quantify the effect of the crystallization process on lithium disilicate ceramic crowns fabricated using a computer-aided design/computer-aided manufacturing (CAD/CAM) system and to determine whether the effect of crystallization is clinically acceptable by comparing values of fit before and after the crystallization process. The mandibular right first molar was selected as the abutment for the experiments. Fifteen working models were prepared. Lithium disilicate crowns appropriate for each abutment were prepared using a commercial CAD/CAM system. Gaps in the marginal area and 4 internal areas of each crown were measured twice—before and after crystallization—using the silicone replica technique. The mean values of fit before and after crystallization were analyzed using a paired t-test to examine whether the conversion that occurred during crystallization affected marginal and internal gaps (α = 0.05). Gaps increased in the marginal area and decreased in the internal areas after crystallization. There were statistically significant differences in all of the investigated areas (P < 0.05). None of the values for marginal and internal fit of lithium disilicate CAD/CAM crowns after crystallization exceeded 120 μm, which is the clinically acceptable threshold. PMID:27123453
A conserved role for Drosophila Neuroglian and human L1-CAM in central-synapse formation.
Godenschwege, Tanja A; Kristiansen, Lars V; Uthaman, Smitha B; Hortsch, Michael; Murphey, Rodney K
2006-01-10
Drosophila Neuroglian (Nrg) and its vertebrate homolog L1-CAM are cell-adhesion molecules (CAM) that have been well studied in early developmental processes. Mutations in the human gene result in a broad spectrum of phenotypes (the CRASH-syndrome) that include devastating neurological disorders such as spasticity and mental retardation. Although the role of L1-CAMs in neurite extension and axon pathfinding has been extensively studied, much less is known about their role in synapse formation. We found that a single extracellular missense mutation in nrg(849) mutants disrupted the physiological function of a central synapse in Drosophila. The identified giant neuron in nrg(849) mutants made a synaptic terminal on the appropriate target, but ultrastructural analysis revealed in the synaptic terminal a dramatic microtubule reduction, which was likely to be the cause for disrupted active zones. Our results reveal that tyrosine phosphorylation of the intracellular ankyrin binding motif was reduced in mutants, and cell-autonomous rescue experiments demonstrated the indispensability of this tyrosine in giant-synapse formation. We also show that this function in giant-synapse formation was conserved in human L1-CAM but neither in human L1-CAM with a pathological missense mutation nor in two isoforms of the paralogs NrCAM and Neurofascin. We conclude that Nrg has a function in synapse formation by organizing microtubules in the synaptic terminal. This novel synaptic function is conserved in human L1-CAM but is not common to all L1-type proteins. Finally, our findings suggest that some aspects of L1-CAM-related neurological disorders in humans may result from a disruption in synapse formation rather than in axon pathfinding.
Integrating Cloud Processes in the Community Atmosphere Model, Version 5.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, S.; Bretherton, Christopher S.; Rasch, Philip J.
2014-09-15
This paper provides a description on the parameterizations of global cloud system in CAM5. Compared to the previous versions, CAM5 cloud parameterization has the following unique characteristics: (1) a transparent cloud macrophysical structure that has horizontally non-overlapped deep cumulus, shallow cumulus and stratus in each grid layer, each of which has own cloud fraction, mass and number concentrations of cloud liquid droplets and ice crystals, (2) stratus-radiation-turbulence interaction that allows CAM5 to simulate marine stratocumulus solely from grid-mean RH without relying on the stability-based empirical empty stratus, (3) prognostic treatment of the number concentrations of stratus liquid droplets and icemore » crystals with activated aerosols and detrained in-cumulus condensates as the main sources and evaporation-sedimentation-precipitation of stratus condensate as the main sinks, and (4) radiatively active cumulus. By imposing consistency between diagnosed stratus fraction and prognosed stratus condensate, CAM5 is free from empty or highly-dense stratus at the end of stratus macrophysics. CAM5 also prognoses mass and number concentrations of various aerosol species. Thanks to the aerosol activation and the parameterizations of the radiation and stratiform precipitation production as a function of the droplet size, CAM5 simulates various aerosol indirect effects associated with stratus as well as direct effects, i.e., aerosol controls both the radiative and hydrological budgets. Detailed analysis of various simulations revealed that CAM5 is much better than CAM3/4 in the global performance as well as the physical formulation. However, several problems were also identifed, which can be attributed to inappropriate regional tuning, inconsistency between various physics parameterizations, and incomplete model physics. Continuous efforts are going on to further improve CAM5.« less
Gray, Rachel; Gougoutas, Alexander; Nguyen, Vinh; Taylor, Jesse; Bastidas, Nicholas
2017-06-01
Virtual Surgical Planning (VSP) and computer-aided design/computer-aided manufacturing (CAD/CAM) have recently helped improve efficiency and accuracy in many different craniofacial surgeries. Research has mainly focused on the use in the adult population with the exception of the use for mandibular distractions and cranial vault remodeling in the pediatric population. This study aims to elucidate the role of VSP and CAD/CAM in complex pediatric craniofacial cases by exploring its use in the correction of midface hypoplasia, orbital dystopia, mandibular reconstruction, and posterior cranial vault expansion. A retrospective analysis of thirteen patients who underwent 3d, CAD/CAM- assisted preoperative surgical planning between 2012 and 2016 was performed. All CAD/CAM assisted surgical planning was done in conjunction with a third party vendor (either 3D Systems or Materialise). Cutting and positioning guides as well as models were produced based on the virtual plan. Surgeries included free fibula mandible reconstruction (n = 4), lefort I osteotomy and distraction (n = 2), lefort II osteotomy with monobloc distraction (n = 1), expansion of the posterior vault for correction of chiari malformation (n = 3), and secondary orbital and midface reconstruction for facial trauma (n = 3). The patient's age, diagnosis, previous surgeries, length of operating time, complications, and post-surgery satisfaction were determined. In all cases we found presurgical planning was helpful to improve accuracy and significantly decrease intra-operative time. In cases where distraction was used, the planned and actual vectors were found to be accurate with excellent clinical outcomes. There were no complications except for one patient who experienced a wound infection post-operatively which did not alter the ultimate reconstruction. All patients experienced high satisfaction with their outcomes and excellent subjective aesthetic results were achieved. Preoperative planning using CAD/CAM and VSP allows for safe and precise craniofacial reconstruction in complex pediatric cases with a reduction of operative time. Copyright © 2017 Elsevier B.V. All rights reserved.
Calculation and Visualization of Atomistic Mechanical Stresses in Nanomaterials and Biomolecules
Gilson, Michael K.
2014-01-01
Many biomolecules have machine-like functions, and accordingly are discussed in terms of mechanical properties like force and motion. However, the concept of stress, a mechanical property that is of fundamental importance in the study of macroscopic mechanics, is not commonly applied in the biomolecular context. We anticipate that microscopical stress analyses of biomolecules and nanomaterials will provide useful mechanistic insights and help guide molecular design. To enable such applications, we have developed Calculator of Atomistic Mechanical Stress (CAMS), an open-source software package for computing atomic resolution stresses from molecular dynamics (MD) simulations. The software also enables decomposition of stress into contributions from bonded, nonbonded and Generalized Born potential terms. CAMS reads GROMACS topology and trajectory files, which are easily generated from AMBER files as well; and time-varying stresses may be animated and visualized in the VMD viewer. Here, we review relevant theory and present illustrative applications. PMID:25503996
Calculation and visualization of atomistic mechanical stresses in nanomaterials and biomolecules.
Fenley, Andrew T; Muddana, Hari S; Gilson, Michael K
2014-01-01
Many biomolecules have machine-like functions, and accordingly are discussed in terms of mechanical properties like force and motion. However, the concept of stress, a mechanical property that is of fundamental importance in the study of macroscopic mechanics, is not commonly applied in the biomolecular context. We anticipate that microscopical stress analyses of biomolecules and nanomaterials will provide useful mechanistic insights and help guide molecular design. To enable such applications, we have developed Calculator of Atomistic Mechanical Stress (CAMS), an open-source software package for computing atomic resolution stresses from molecular dynamics (MD) simulations. The software also enables decomposition of stress into contributions from bonded, nonbonded and Generalized Born potential terms. CAMS reads GROMACS topology and trajectory files, which are easily generated from AMBER files as well; and time-varying stresses may be animated and visualized in the VMD viewer. Here, we review relevant theory and present illustrative applications.
NASA Astrophysics Data System (ADS)
Hudson, C. A.
1982-02-01
CAD/CAM advances and applications for enhancing productivity in industry are explored. Wide-spread use of CAD/CAM devices are projected to occur by the time period 1992-1997, resulting in a higher percentage of technicians in the manufacturing process, while the cost of computers and software will continue to fall and become more widely available. Computer aided design is becoming a commercially viable system for design and geometric modeling, engineering analysis, kinematics, and drafting, and efforts to bridge the gap between CAD and CAM are indicated, with particular attention given to layering, wherein individual monitoring of different parts of the manufacturing process can be effected without crossover of unnecessary information. The potentials and barriers to the use of robotics are described, with the added optimism that displaced workers to date have moved up to jobs of higher skill and interest.
Support system, excavation arrangement, and process of supporting an object
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arnold, Bill W.
2017-08-01
A support system, an excavation arrangement, and a process of supporting an object are disclosed. The support system includes a weight-bearing device and a camming mechanism positioned below the weight-bearing device. A downward force on the weight-bearing device at least partially secures the camming mechanism to opposing surfaces. The excavation arrangement includes a borehole, a support system positioned within and secured to the borehole, and an object positioned on and supported by the support system. The process includes positioning and securing the support system and positioning the object on the weight-bearing device.
NASA Astrophysics Data System (ADS)
Yao, Zhixiong; Tang, Youmin; Chen, Dake; Zhou, Lei; Li, Xiaojing; Lian, Tao; Ul Islam, Siraj
2016-12-01
This study examines the possible impacts of coupling processes on simulations of the Indian Ocean Dipole (IOD). Emphasis is placed on the atmospheric model resolution and physics. Five experiments were conducted for this purpose, including one control run of the ocean-only model, four coupled experiments using two different versions of the Community Atmosphere Model (CAM4 and CAM5) and two different resolutions. The results show that the control run could effectively simulate various features of the IOD. The coupled experiments run at the higher resolution yielded more realistic IOD period and intensity than their counterparts at the low resolution. The coupled experiments using CAM5 generally showed a better simulation skill in the tropical Indian SST climatology and phase-locking than those using CAM4, but the wind anomalies were stronger and the IOD period were longer in the former experiments than in the latter. In all coupled experiments, the IOD intensity was much stronger than the observed intensity, which is attributable to wind-thermocline depth feedback and thermocline depth-subsurface temperature feedback. The CAM5 physics seems beneficial for the simulation of summer rainfall over the eastern equatorial Indian Ocean and the CAM4 physics tends to produce less biases over the western equatorial Indian Ocean, whereas the higher resolution tends to generate unrealistically strong meridional winds. The IOD-ENSO relationship was captured reasonably well in coupled experiments, with improvements in CAM5 relative to CAM4. However, the teleconnection of the IOD-Indian summer monsoon and ENSO-Indian summer monsoon was not realistically simulated in all experiments.
CAD/CAM produces dentures with improved fit.
Steinmassl, Otto; Dumfahrt, Herbert; Grunert, Ingrid; Steinmassl, Patricia-Anca
2018-02-22
Resin polymerisation shrinkage reduces the congruence of the denture base with denture-bearing tissues and thereby decreases the retention of conventionally fabricated dentures. CAD/CAM denture manufacturing is a subtractive process, and polymerisation shrinkage is not an issue anymore. Therefore, CAD/CAM dentures are assumed to show a higher denture base congruence than conventionally fabricated dentures. It has been the aim of this study to test this hypothesis. CAD/CAM dentures provided by four different manufacturers (AvaDent, Merz Dental, Whole You, Wieland/Ivoclar) were generated from ten different master casts. Ten conventional dentures (pack and press, long-term heat polymerisation) made from the same master casts served as control group. The master casts and all denture bases were scanned and matched digitally. The absolute incongruences were measured using a 2-mm mesh. Conventionally fabricated dentures showed a mean deviation of 0.105 mm, SD = 0.019 from the master cast. All CAD/CAM dentures showed lower mean incongruences. From all CAD/CAM dentures, AvaDent Digital Dentures showed the highest congruence with the master cast surface with a mean deviation of 0.058 mm, SD = 0.005. Wieland Digital Dentures showed a mean deviation of 0.068 mm, SD = 0.005, Whole You Nexteeth prostheses showed a mean deviation of 0.074 mm, SD = 0.011 and Baltic Denture System prostheses showed a mean deviation of 0.086 mm, SD = 0.012. CAD/CAM produces dentures with better fit than conventional dentures. The present study explains the clinically observed enhanced retention and lower traumatic ulcer-frequency in CAD/CAM dentures.
NASA Technical Reports Server (NTRS)
Reddy, A. S.; Reddy, V. S.; Golovkin, M.
2000-01-01
Calmodulin (CaM), a key calcium sensor in all eukaryotes, regulates diverse cellular processes by interacting with other proteins. To isolate CaM binding proteins involved in ethylene signal transduction, we screened an expression library prepared from ethylene-treated Arabidopsis seedlings with 35S-labeled CaM. A cDNA clone, EICBP (Ethylene-Induced CaM Binding Protein), encoding a protein that interacts with activated CaM was isolated in this screening. The CaM binding domain in EICBP was mapped to the C-terminus of the protein. These results indicate that calcium, through CaM, could regulate the activity of EICBP. The EICBP is expressed in different tissues and its expression in seedlings is induced by ethylene. The EICBP contains, in addition to a CaM binding domain, several features that are typical of transcription factors. These include a DNA-binding domain at the N terminus, an acidic region at the C terminus, and nuclear localization signals. In database searches a partial cDNA (CG-1) encoding a DNA-binding motif from parsley and an ethylene up-regulated partial cDNA from tomato (ER66) showed significant similarity to EICBP. In addition, five hypothetical proteins in the Arabidopsis genome also showed a very high sequence similarity with EICBP, indicating that there are several EICBP-related proteins in Arabidopsis. The structural features of EICBP are conserved in all EICBP-related proteins in Arabidopsis, suggesting that they may constitute a new family of DNA binding proteins and are likely to be involved in modulating gene expression in the presence of ethylene.
Women’s Sleep Disorders: Integrative Care
Frange, Cristina; Banzoli, Carolina Vicente; Colombo, Ana Elisa; Siegler, Marcele; Coelho, Glaury; Bezerra, Andréia Gomes; Csermak, Marcelo; Naufel, Maria Fernanda; Cesar-Netto, Cristiana; Andersen, Monica Levy; Girão, Manoel João Batista Castelo; Tufik, Sergio; Hachul, Helena
2017-01-01
The integrative care model is rooted in a biopsychosocial approach. Integrative is a term which refers to increasing the harmony and coherence of your whole being, and integrative care is therefore focused on the person, not on either the disease or a therapy. It is provided collaboratively by a health team comprising physicians, psychologists, physiotherapists, acupuncturists, and meditation, nutrition, and floral therapy. Previous studies have demonstrated that interventions based on the integrative care model improved womens lifestyle and quality of life. Our aim was to describe the use of complementary and alternative medicine (CAM) alongside traditional medicine among women with sleep conditions in our Womens Sleep Disorders Integrative Treatment Outpatient Clinic. We are sharing our experiences and clinical practice as the model we developed seems to have both physical and psychological benefits for women with sleep problems. We discuss the wide range of benefits that result from this type of complex intervention, and the contextual factors that may influence these benefits. This will inform future practitioners and we hope to contribute to quantitative research in the clinical setting. The study highlights the importance of treating sleep complaints with a caring relationship and a CAM approach, alongside conventional medicine. Exploration of the lived experience of CAM and its meaning enables healthcare professionals to gain insights into the patients needs, preferences, and values. Gynecologists, clinicians, and health care providers should support and guide patients in their decision to use CAM by providing evidence-based and comprehensive advice on the potential benefits, risks and related safety issues of this approach. PMID:29410750
Product Recommendation System Based on Personal Preference Model Using CAM
NASA Astrophysics Data System (ADS)
Murakami, Tomoko; Yoshioka, Nobukazu; Orihara, Ryohei; Furukawa, Koichi
Product recommendation system is realized by applying business rules acquired by data maining techniques. Business rules such as demographical patterns of purchase, are able to cover the groups of users that have a tendency to purchase products, but it is difficult to recommend products adaptive to various personal preferences only by utilizing them. In addition to that, it is very costly to gather the large volume of high quality survey data, which is necessary for good recommendation based on personal preference model. A method collecting kansei information automatically without questionnaire survey is required. The constructing personal preference model from less favor data is also necessary, since it is costly for the user to input favor data. In this paper, we propose product recommendation system based on kansei information extracted by text mining and user's preference model constructed by Category-guided Adaptive Modeling, CAM for short. CAM is a feature construction method that can generate new features constructing the space where same labeled examples are close and different labeled examples are far away from some labeled examples. It is possible to construct personal preference model by CAM despite less information of likes and dislikes categories. In the system, retrieval agent gathers the products' specification and user agent manages preference model, user's likes and dislikes. Kansei information of the products is gained by applying text mining technique to the reputation documents about the products on the web site. We carry out some experimental studies to make sure that prefrence model obtained by our method performs effectively.
Applications of 3D orbital computer-assisted surgery (CAS).
Scolozzi, P
2017-09-01
The purpose of the present report is to describe the indications for use of 3D orbital computer-assisted surgery (CAS). We analyzed the clinical and radiological data of all patients with orbital deformities treated using intra-operative navigation and CAD/CAM techniques at the Hôpitaux Universitaires de Genève, Switzerland, between 2009 and 2016. We recorded age and gender, orbital deformity, technical and surgical procedure and postoperative complications. One hundred and three patients were included. Mean age was 39.5years (range, 5 to 84years) and 85 (87.5%) were men. Of the 103 patients, 96 had intra-operative navigation (34 for primary and 3 for secondary orbito-zygomatic fractures, 15 for Le Fort fractures, 16 for orbital floor fractures, 10 for combined orbital floor and medial wall fractures, 7 for orbital medial wall fractures, 3 for NOE (naso-orbito-ethmoidal) fractures, 2 for isolated comminuted zygomatic arch fractures, 1 for enophthalmos, 3 for TMJ ankylosis and 2 for fibrous dysplasia bone recontouring), 8 patients had CAD/CAM PEEK-PSI for correction of residual orbital bone contour following craniomaxillofacial trauma, and 1 patient had CAD/CAM surgical splints and cutting guides for correction of orbital hypertelorism. Two patient (1.9%) required revision surgery for readjustment of an orbital mesh. The 1-year follow-up examination showed stable cosmetic and dimensional results in all patients. This study demonstrated that the application of 3D orbital CAS with regards to intra-operative navigation and CAD/CAM techniques allowed for a successful outcome in the patients presented in this series. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Taybi, Tahar; Cushman, John C; Borland, Anne M
2017-11-01
Nocturnal degradation of transitory starch is a limiting factor for the optimal function of crassulacean acid metabolism and must be coordinated with phosphoenolypyruvate carboxylase (PEPC)-mediated CO 2 uptake to optimise carbon gain over the diel cycle. The aim of this study was to test the hypothesis that nocturnal carboxylation is coordinated with starch degradation in CAM via a mechanism whereby the products of these pathways regulate diel transcript abundance and enzyme activities for both processes. To test this hypothesis, a starch and CAM-deficient mutant of Mesembryanthemum crystallinum was compared with wild type plants under well-watered and saline (CAM-inducing) conditions. Exposure to salinity increased the transcript abundance of genes required for nocturnal carboxylation, starch and sucrose degradation in both wild type and mutant, but the transcript abundance of several of these genes was not sustained over the dark period in the low-carbohydrate, CAM-deficient mutant. The diel pattern of transcript abundance for PEPC mirrored that of PEPC protein, as did the transcripts, protein, and activity of chloroplastic starch phosphorylase in both wild type and mutant, suggesting robust diel coordination of these metabolic processes. Activities of several amylase isoforms were low or lacking in the mutant, whilst the activity of a cytosolic isoform of starch phosphorylase was significantly elevated, indicating contrasting modes of metabolic regulation for the hydrolytic and phosphorylytic routes of starch degradation. Externally supplied sucrose resulted in an increase in nocturnal transcript abundance of genes required for nocturnal carboxylation and starch degradation. These results demonstrate that carbohydrates impact on transcriptional and post-transcriptional regulation of nocturnal carboxylation and starch degradation in CAM. Copyright © 2017 Elsevier GmbH. All rights reserved.
NASA Astrophysics Data System (ADS)
Orton, Glenn; Hansen, Candice; Momary, Thomas; Bolton, Scott
2017-04-01
Among the many "firsts" of the Juno mission is the open enlistment of the public in the operation of its visible camera, JunoCam. Although the scientific thrust of the Juno mission is largely focused on innovative approaches to understanding the structure and composition of Jupiter's interior, JunoCam was added to the payload largely to function in the role of education and public outreach (E/PO). For the first time, the public was able to engage in the discussion and choice of targets for a major NASA mission. The discussion about which features to image is enabled by a continuously updated map of Jupiter's cloud system while Jupiter is far enough from the sun to be observable by non-professional astronomers. Contributors range from very devoted astrophotographers to telescope and video 'hobbyists'. Juno therefore engages the world-wide amateur-astronomy community as a vast network of co-investigators, whose products stimulate conversation and global public awareness of Jupiter and Juno's investigative role. Contributed images also provide a temporal context to inform the Juno atmospheric investigation team of the state and evolution of the atmosphere. The contributed images are used to create s global map on a bi-weekly basis. These bi-weekly maps provide the focus for ongoing discussion about various planetary features over a long time frame. Approximately two weeks before Juno's closest approach to Jupiter on each orbit ("perijove" or PJ), starting in mid-November of 2016 in preparation for PJ3 on December 11, the atmospheric features that have been under discussion and available to JunoCam on that perijove were nominated for voting, and the public at large voted on where to point JunoCam's "elective" features. In addition, JunoCam provides the first close-up images of Jupiter's polar regions from a non-oblique viewpoint for the first time in over 40 years since the passage of Pioneer 11 over Jupiter's north pole. The Juno mission science team also provides additional comments on features from their various points of view, but Juno's science team has no greater weighting in the voting process than the public at large, short of an extraordinary event, such as an impact event or a sudden atmospheric outburst. Public voting was tested for the first time on three regions for PJ3 and has continued for PJ4 and PJ5 with voting on nearly all non-polar images. One of the big challenges in this process was the accurate prediction of which features would be in the field of view at the time of the perijove some 10 days following the end of voting, due to Jupiter's differential rotation. The results of public processing and re-posting of JunoCam images have ranged all the way from artistic renditions up to professional-equivalent analysis that is equivalent to anything JunoCam team members could have produced. All aspects of this effort are available on the Mission Juno web site, linked to the JunoCam instrument (https://www.missionjuno.swri.edu/junocam/).
Jensen, Drake; Reynolds, Nicole; Yang, Ya-Ping; Shakya, Shubha; Wang, Zhi-Qiang; Stuehr, Dennis J; Wei, Chin-Chuan
2015-02-15
Calmodulin (CaM) plays an important role in Ca(2+)-dependent signal transduction. Ca(2+) binding to CaM triggers a conformational change, forming a hydrophobic patch that is important for target protein recognition. CaM regulates a Ca(2+)-dependent inactivation process in store-operated Ca(2+) entry, by interacting Orai1. To understand the relationship between Ca(2+)-induced hydrophobicity and CaM/Orai interaction, chimera proteins constructed by exchanging EF-hands of CaM with those of Troponin C (TnC) are used as an informative probe to better understand the functionality of each EF-hand. ANS was used to assess the context of the induced hydrophobic surface on CaM and chimeras upon Ca(2+) binding. The exchanged EF-hands from TnC to CaM resulted in reduced hydrophobicity compared with wild-type CaM. ANS lifetime measurements indicated that there are two types of ANS molecules with rather distinct fluorescence lifetimes, each specifically corresponding to one lobe of CaM or chimeras. Thermodynamic studies indicated the interaction between CaM and a 24-residue peptide corresponding to the CaM-binding domain of Orail1 (Orai-CMBD) is a 1:2 CaM/Orai-CMBD binding, in which each peptide binding yields a similar enthalpy change (ΔH = -5.02 ± 0.13 kcal/mol) and binding affinity (K(a) = 8.92 ± 1.03 × 10(5) M(-1)). With the exchanged EF1 and EF2, the resulting chimeras noted as CaM(1TnC) and CaM(2TnC), displayed a two sequential binding mode with a one-order weaker binding affinity and lower ΔH than that of CaM, while CaM(3TnC) and CaM(4TnC) had similar binding thermodynamics as CaM. The dissociation rate constant for CaM/Orai-CMBD was determined to be 1.41 ± 0.08 s(-1) by rapid kinetics. Stern-Volmer plots of Orai-CMBD Trp76 indicated that the residue is located in a very hydrophobic environment but becomes more solvent accessible when EF1 and EF2 were exchanged. Using ANS dye to assess induced hydrophobicity showed that exchanging EFs for all Ca(2+)-bound chimeras impaired ANS fluorescence and/or binding affinity, consistent with general concepts about the inadequacy of hydrophobic exposure for chimeras. However, such ANS responses exhibited no correlation with the ability to interact with Orai-CMBD. Here, the model of 1:2 binding stoichiometry of CaM/Orai-CMBD established in solution supports the already published crystal structure.
Akerboom, Jasper; Rivera, Jonathan D Vélez; Guilbe, María M Rodríguez; Malavé, Elisa C Alfaro; Hernandez, Hector H; Tian, Lin; Hires, S Andrew; Marvin, Jonathan S; Looger, Loren L; Schreiter, Eric R
2009-03-06
The genetically encoded calcium indicator GCaMP2 shows promise for neural network activity imaging, but is currently limited by low signal-to-noise ratio. We describe x-ray crystal structures as well as solution biophysical and spectroscopic characterization of GCaMP2 in the calcium-free dark state, and in two calcium-bound bright states: a monomeric form that dominates at intracellular concentrations observed during imaging experiments and an unexpected domain-swapped dimer with decreased fluorescence. This series of structures provides insight into the mechanism of Ca2+-induced fluorescence change. Upon calcium binding, the calmodulin (CaM) domain wraps around the M13 peptide, creating a new domain interface between CaM and the circularly permuted enhanced green fluorescent protein domain. Residues from CaM alter the chemical environment of the circularly permuted enhanced green fluorescent protein chromophore and, together with flexible inter-domain linkers, block solvent access to the chromophore. Guided by the crystal structures, we engineered a series of GCaMP2 point mutants to probe the mechanism of GCaMP2 function and characterized one mutant with significantly improved signal-to-noise. The mutation is located at a domain interface and its effect on sensor function could not have been predicted in the absence of structural data.
Kitani, Takako; Okuno, Sachiko; Takeuchi, Masayuki; Fujisawa, Hitoshi
2003-07-01
Ca2+/Calmodulin-dependent protein kinase (CaM kinase) regulatory system is composed of multifunctional CaM kinases such as CaM kinases IV and I, upstream CaM kinases such as CaM kinase kinases alpha and beta, which activate multifunctional CaM kinases, and CaM kinase phosphatases such as CaM kinase phosphatase and CaM kinase phosphatase N, which deactivate the activated multifunctional CaM kinases. To understand the combinations of CaM kinases I and IV, CaM kinase kinases alpha and beta, and CaM kinase phosphatases, the locations of the enzymes in the cell were examined by immunocytochemical studies of cultured cells. The results indicate that CaM kinase I, CaM kinase kinase beta, and CaM kinase phosphatase occur in the cytoplasm and that CaM kinase IV, CaM kinase kinase alpha (and CaM kinase kinase beta in some cell types and tissues), and CaM kinase phosphatase N occur inside the cellular nucleus, suggesting that there are at least two different sets of CaM kinase regulatory systems, one consisting of CaM kinase I, CaM kinase kinase beta, and CaM kinase phosphatase in the cytoplasm and the other consisting of CaM kinase IV, CaM kinase kinase alpha (and CaM kinase kinase beta in some cell types and tissues), and CaM kinase phosphatase N in the nucleus.
JunoCam: Outreach and Science Opportunities
NASA Astrophysics Data System (ADS)
Hansen, Candice; Ingersoll, Andy; Caplinger, Mike; Ravine, Mike; Orton, Glenn
2014-11-01
JunoCam is a visible imager on the Juno spacecraft en route to Jupiter. Although the primary role of the camera is for outreach, science objectives will be addressed too. JunoCam is a wide angle camera (58 deg field of view) with 4 color filters: red, green and blue (RGB) and methane at 889 nm. Juno’s elliptical polar orbit will offer unique views of Jupiter’s polar regions with a spatial scale of ~50 km/pixel. The polar vortex, polar cloud morphology, and winds will be investigated. RGB color mages of the aurora will be acquired. Stereo images and images taken with the methane filter will allow us to estimate cloudtop heights. Resolution exceeds that of Cassini about an hour from closest approach and at closest approach images will have a spatial scale of ~3 km/pixel. JunoCam is a push-frame imager on a rotating spacecraft. The use of time-delayed integration takes advantage of the spacecraft spin to build up signal. JunoCam will acquire limb-to-limb views of Jupiter during a spacecraft rotation, and has the possibility of acquiring images of the rings from in-between Jupiter and the inner edge of the rings. Galilean satellite views will be fairly distant but some images will be acquired. Outer irregular satellites and small ring moons Metis and Adrastea will also be imaged. The theme of our outreach is “science in a fish bowl”, with an invitation to the science community and the public to participate. Amateur astronomers will supply their ground-based images for planning, so that we can predict when prominent atmospheric features will be visible. With the aid of professional astronomers observing at infrared wavelengths, we’ll predict when hot spots will be visible to JunoCam. Amateur image processing enthusiasts are onboard to create image products. Many of the earth flyby image products from Juno’s earth gravity assist were processed by amateurs. Between the planning and products will be the decision-making on what images to take when and why. We invite our colleagues to propose science questions for JunoCam to address, and to be part of the participatory process of deciding how to use our resources and scientifically analyze the data.
Interprofessional collaboration within Canadian integrative healthcare clinics: Key components.
Gaboury, Isabelle; Bujold, Mathieu; Boon, Heather; Moher, David
2009-09-01
Research shows that interprofessional collaboration has become an important factor in the implementation of effective healthcare models. To date, the literature has not focused on the collaboration between medical doctors and complementary and alternative medicine (CAM) healthcare practitioners, an example of interdisciplinary collaboration called integrative healthcare (IHC). Drawing on in-depth, semi-standardized interviews conducted with 21 practitioners working in Canadian IHC clinics, this paper explored and interpreted how IHC is experienced by those working in Canadian IHC clinics. The interview questions and analysis were guided by the Input, Process, Output conceptual framework drawn from the organizational management theory (McGrath, J. E. (1964). Social psychology: A brief introduction. New York: Holt, Rinehart and Winston.) to study collaboration within teams. We found that constructs contributing to collaboration included practitioners' attitudes and educational background, as well as external factors such as the healthcare system and financial pressures. Major processes affecting collaboration included communication, patient referral and power relationships. These determinants of collaboration were found to result in learning opportunities for practitioners, modified burden of work and ultimately, higher affective commitment toward the clinic. These constructs serve as a guide for further investigation of interprofessional collaboration within an IHC clinic. This exploration of interprofessional collaboration in IHC identified a broad array of key factors associated with interprofessional collaboration. These factors are critical to better understand the functioning of IHC clinics, and provide guidance for creation or maintenance of successful clinics.
Finley, Jason R; Brewer, William F; Benjamin, Aaron S
2011-10-01
Emerging "life-logging" technologies have tremendous potential to augment human autobiographical memory by recording and processing vast amounts of information from an individual's experiences. In this experiment undergraduate participants wore a SenseCam, a small, sensor-equipped digital camera, as they went about their normal daily activities for five consecutive days. Pictures were captured either at fixed intervals or as triggered by SenseCam's sensors. On two of five nights, participants watched an end-of-day review of a random subset of pictures captured that day. Participants were tested with a variety of memory measures at intervals of 1, 3, and 8 weeks. The most fruitful of six measures were recognition rating (on a 1-7 scale) and picture-cued recall length. On these tests, end-of-day review enhanced performance relative to no review, while pictures triggered by SenseCam's sensors showed little difference in performance compared to those taken at fixed time intervals. We discuss the promise of SenseCam as a tool for research and for improving autobiographical memory.
NASA Astrophysics Data System (ADS)
Gottfried, Varda; Lindenbaum, Ella S.; Kimel, Sol; Hammer-Wilson, Marie J.; Berns, Michael W.
1991-04-01
The mechanism of photodynamic therapy (PDT) involves, as a primary step, damage either directly to the tumor cells or to the surrounding vasculature which, in turn, causes disruption of tumor blood flow and, ultimately, tissue necrosis by anoxia. We report here a novel in-vivo model for investigating vascular events during PDT. The chick chorioallantoic membrane (CAM) model was chosen since it is an established model for studying biological processes such as implantation and angiogenesis . The photosensitizers meso-tetraphenylporphine tetrasulfonate (TPPSJ and chloro-aluminum phthalocyanine tetrasulfonate (CAPcS) were topically applied onto the CAM. In all cases where sensitizer plus radiation was administered, changes in the CAM microcirculation occurred, as viewed through a stereoscopic microscope. With increasing light/drug dose we observed capillary leakage, stasis, occlusion, hemorrhage, and engorgement. The course of damage formation was documented in real time by video photography. All controls (sensitizer alone or light alone) remained unchanged compared to treated CAM. This work also describes preliminary experiments on tumor cells transplanted onto the CAM.
Cellular distribution of calmodulin and calmodulin-binding proteins in Vicia faba L
NASA Technical Reports Server (NTRS)
Ling, V.; Assmann, S. M.
1992-01-01
The distribution of calmodulin (CaM) and CaM-binding proteins within Vicia faba was investigated. Both CaM and CaM-binding proteins were found to be differentially distributed among organs, tissues, and protoplast types. CaM levels, on a per protein basis, were found to be the highest in leaf epidermis, containing 3-fold higher levels of CaM than in total leaf. Similarly, guard cell and epidermal cell protoplasts were also found to have higher levels of CaM than mesophyll cell protoplasts. 125I-CaM blot overlay assays were performed to qualitatively examine CaM-binding proteins in these protoplast types as well as in whole tissues and organs. CaM-binding proteins with Mr 52,000, 78,000, and 115,000 were common in all metabolically active plant parts. Unique CaM-binding protein bands were detected in guard cell protoplasts (Mr 39,000, 88,000), stems (Mr 45,000, 60,000, 64,000), and roots (Mr 62,000), suggesting the presence of specialized CaM-dependent processes in these cells and organs.
Winter, Klaus; Holtum, Joseph A.M.
2007-01-01
The relative influence of plant age and environmental stress signals in triggering a shift from C3 photosynthesis to Crassulacean acid metabolism (CAM) in the annual halophytic C3-CAM species Mesembryanthemum crystallinum was explored by continuously monitoring net CO2 exchange of whole shoots from the seedling stage until seed set. Plants exposed to high salinity (400 mm NaCl) in hydroponic culture solution or grown in saline-droughted soil acquired between 11% and 24% of their carbon via net dark CO2 uptake involving CAM. In contrast, plants grown under nonsaline, well-watered conditions were capable of completing their life cycle by operating in the C3 mode without ever exhibiting net CO2 uptake at night. These observations are not consistent with the widely expressed view that the induction of CAM by high salinity in M. crystallinum represents an acceleration of preprogrammed developmental processes. Rather, our study demonstrates that the induction of the CAM pathway for carbon acquisition in M. crystallinum is under environmental control. PMID:17056756
Winter, Klaus; Holtum, Joseph A M
2007-01-01
The relative influence of plant age and environmental stress signals in triggering a shift from C(3) photosynthesis to Crassulacean acid metabolism (CAM) in the annual halophytic C(3)-CAM species Mesembryanthemum crystallinum was explored by continuously monitoring net CO(2) exchange of whole shoots from the seedling stage until seed set. Plants exposed to high salinity (400 mm NaCl) in hydroponic culture solution or grown in saline-droughted soil acquired between 11% and 24% of their carbon via net dark CO(2) uptake involving CAM. In contrast, plants grown under nonsaline, well-watered conditions were capable of completing their life cycle by operating in the C(3) mode without ever exhibiting net CO(2) uptake at night. These observations are not consistent with the widely expressed view that the induction of CAM by high salinity in M. crystallinum represents an acceleration of preprogrammed developmental processes. Rather, our study demonstrates that the induction of the CAM pathway for carbon acquisition in M. crystallinum is under environmental control.
Cell Division Induces and Switches Coherent Angular Motion within Bounded Cellular Collectives.
Siedlik, Michael J; Manivannan, Sriram; Kevrekidis, Ioannis G; Nelson, Celeste M
2017-06-06
Collective cell migration underlies many biological processes, including embryonic development, wound healing, and cancer progression. In the embryo, cells have been observed to move collectively in vortices using a mode of collective migration known as coherent angular motion (CAM). To determine how CAM arises within a population and changes over time, here, we study the motion of mammary epithelial cells within engineered monolayers, in which the cells move collectively about a central axis in the tissue. Using quantitative image analysis, we find that CAM is significantly reduced when mitosis is suppressed. Particle-based simulations recreate the observed trends, suggesting that cell divisions drive the robust emergence of CAM and facilitate switches in the direction of collective rotation. Our simulations predict that the location of a dividing cell, rather than the orientation of the division axis, facilitates the onset of this motion. These predictions agree with experimental observations, thereby providing, to our knowledge, new insight into how cell divisions influence CAM within a tissue. Overall, these findings highlight the dynamic nature of CAM and suggest that regulating cell division is crucial for tuning emergent collective migratory behaviors, such as vortical motions observed in vivo. Copyright © 2017 Biophysical Society. Published by Elsevier Inc. All rights reserved.
Research methods in complementary and alternative medicine: an integrative review.
de Almeida Andrade, Fabiana; Schlechta Portella, Caio Fabio
2018-01-01
The scientific literature presents a modest amount of evidence in the use of complementary and alternative medicine (CAM). On the other hand, in practice, relevant results are common. The debates among CAM practitioners about the quality and execution of scientific research are important. Therefore, the aim of this review is to gather, synthesize and describe the differentiated methodological models that encompass the complexity of therapeutic interventions. The process of bringing evidence-based medicine into clinical practice in CAM is essential for the growth and strengthening of complementary medicines worldwide. Copyright © 2017 Shanghai Changhai Hospital. Published by Elsevier B.V. All rights reserved.
Ye, Hongqiang; Li, Xinxin; Wang, Guanbo; Kang, Jing; Liu, Yushu; Sun, Yuchun; Zhou, Yongsheng
2018-02-15
To investigate a computer-aided design/computer-aided manufacturing (CAD/CAM) process for producing one-piece removable partial dentures (RPDs) and to evaluate their fits in vitro. A total of 15 one-piece RPDs were designed using dental CAD and reverse engineering software and then fabricated with polyetheretherketone (PEEK) using CAM. The gaps between RPDs and casts were measured and compared with traditional cast framework RPDs. Gaps were lower for one-piece PEEK RPDs compared to traditional RPDs. One-piece RPDs can be manufactured by CAD/CAM, and their fits were better than those of traditional RPDs.
Shimoyama, Hiromitsu
2018-05-07
Calmodulin (CaM) is a multifunctional calcium-binding protein, which regulates various biochemical processes. CaM acts via structural changes and complex forming with its target enzymes. CaM has two globular domains (N-lobe and C-lobe) connected by a long linker region. Upon calcium binding, the N-lobe and C-lobe undergo local conformational changes, after that, entire CaM wraps the target enzyme through a large conformational change. However, the regulation mechanism, such as allosteric interactions regulating the conformational changes, is still unclear. In order to clarify the allosteric interactions, in this study, experimentally obtained 'real' structures are compared to 'model' structures lacking the allosteric interactions. As the allosteric interactions would be absent in calcium-free CaM (apo-CaM), allostery-eliminated calcium-bound CaM (holo-CaM) models were constructed by combining the apo-CaM's linker and the holo-CaM's N- and C-lobe. Before the comparison, the 'real' and 'model' structures were clustered and cluster-cluster relationship was determined by a principal component analysis. The structures were compared based on the relationship, then, a distance map and a contact probability analysis clarified that the inter-domain motion is regulated by several groups of inter-domain contacting residue pairs. The analyses suggested that these residues cause inter-domain translation and rotation, and as a consequence, the motion encourage structural diversity. The resultant diversity would contribute to the functional versatility of CaM.
Slanchev, Krasimir; Carney, Thomas J.; Stemmler, Marc P.; Koschorz, Birgit; Amsterdam, Adam; Schwarz, Heinz; Hammerschmidt, Matthias
2009-01-01
The aberrant expression of the transmembrane protein EpCAM is associated with tumor progression, affecting different cellular processes such as cell–cell adhesion, migration, proliferation, differentiation, signaling, and invasion. However, the in vivo function of EpCAM still remains elusive due to the lack of genetic loss-of-function studies. Here, we describe epcam (tacstd) null mutants in zebrafish. Maternal-zygotic mutants display compromised basal protrusive activity and epithelial morphogenesis in cells of the enveloping layer (EVL) during epiboly. In partial redundancy with E-cadherin (Ecad), EpCAM made by EVL cells is further required for cell–cell adhesion within the EVL and, possibly, for proper attachment of underlying deep cells to the inner surface of the EVL, thereby also affecting deep cell epiboly movements. During later development, EpCAM per se becomes indispensable for epithelial integrity within the periderm of the skin, secondarily leading to disrupted morphology of the underlying basal epidermis and moderate hyper-proliferation of skin cells. On the molecular level, EVL cells of epcam mutant embryos display reduced levels of membranous Ecad, accompanied by an enrichment of tight junction proteins and a basal extension of apical junction complexes (AJCs). Our data suggest that EpCAM acts as a partner of E-cadherin to control adhesiveness and integrity as well as plasticity and morphogenesis within simple epithelia. In addition, EpCAM is required for the interaction of the epithelia with underlying cell layers. PMID:19609345
High affinity binding of amyloid β-peptide to calmodulin: Structural and functional implications.
Corbacho, Isaac; Berrocal, María; Török, Katalin; Mata, Ana M; Gutierrez-Merino, Carlos
2017-05-13
Amyloid β-peptides (Aβ) are a major hallmark of Alzheimer's disease (AD) and their neurotoxicity develop with cytosolic calcium dysregulation. On the other hand, calmodulin (CaM), a protein which plays a major multifunctional role in neuronal calcium signaling, has been shown to be involved in the regulation of non-amyloidogenic processing of amyloid β precursor protein (APP). Using fluorescent 6-bromoacetyl-2-dimethylaminonaphthalene derivatives of CaM, Badan-CaM, and human amyloid β(1-42) HiLyte™-Fluor555, we show in this work that Aβ binds with high affinity to CaM through the neurotoxic Aβ25-35 domain. In addition, the affinity of Aβ for calcium-saturated CaM conformation is approximately 20-fold higher than for CaM conformation in the absence of calcium (apo-CaM). Moreover, the value of K d of 0.98 ± 0.11 nM obtained for Aβ1-42 dissociation from CaM saturated by calcium points out that CaM is one of the cellular targets with highest affinity for neurotoxic Aβ peptides. A major functional consequence of Aβ-CaM interaction is that it slowdowns Aβ fibrillation. The novel and high affinity interaction between calmodulin and Aβ shown in this work opens a yet-unexplored gateway to further understand the neurotoxic effect of Aβ in different neural cells and also to address the potential of calmodulin and calmodulin-derived peptides as therapeutic agents in AD. Copyright © 2017 Elsevier Inc. All rights reserved.
Rascher, U; Bobich, E G; Osmond, C B
2006-01-01
Crassulacean acid metabolism (CAM) is recognized as a photosynthetic adaptation of plants to arid habitats. This paper presents a proof-of-concept evaluation of partitioning net CO2 exchanges for soil and plants in an arid, exclusively CAM mesocosm, with soil depth and succulent plant biomass approximating that of natural Sonoran Desert ecosystems. We present the first evidence that an enclosed CAM-dominated soil and plant community exposed to a substantial day/night temperature difference (30/20 degrees C), exhibits a diel gas exchange pattern consisting of four consecutive phases with a distinct nocturnal CO2 uptake. These phases were modulated by plant assimilation and soil respiration processes. Day-time stomatal closure of the CAM cycle during phase III was used to eliminate aboveground photosynthetic assimilation and respiration and thereby to estimate belowground plant plus soil respiration. Rapid changes in temperature appeared to synchronize single plant gas exchange but individual plant gas exchange patterns were desynchronized at constant day/night temperatures (25 degrees C), masking the distinct mesocosm pattern. Overall, the mean carbon budget of this CAM model Sonoran Desert system was negative, releasing an average of 22.5 mmol CO2 m-2 d-1. The capacity for nocturnal CO2 assimilation in this exclusively CAM mesocosm was inadequate to recycle CO2 released by plant and soil respiration.
Algorithmically scalable block preconditioner for fully implicit shallow-water equations in CAM-SE
Lott, P. Aaron; Woodward, Carol S.; Evans, Katherine J.
2014-10-19
Performing accurate and efficient numerical simulation of global atmospheric climate models is challenging due to the disparate length and time scales over which physical processes interact. Implicit solvers enable the physical system to be integrated with a time step commensurate with processes being studied. The dominant cost of an implicit time step is the ancillary linear system solves, so we have developed a preconditioner aimed at improving the efficiency of these linear system solves. Our preconditioner is based on an approximate block factorization of the linearized shallow-water equations and has been implemented within the spectral element dynamical core within themore » Community Atmospheric Model (CAM-SE). Furthermore, in this paper we discuss the development and scalability of the preconditioner for a suite of test cases with the implicit shallow-water solver within CAM-SE.« less
CIM's bridge from CADD to CAM: Data management requirements for manufacturing engineering
NASA Technical Reports Server (NTRS)
Ford, S. J.
1984-01-01
Manufacturing engineering represents the crossroads of technical data management in a Computer Integrated Manufacturing (CIM) environment. Process planning, numerical control programming and tool design are the key functions which translate information from as engineered to as assembled. In order to transition data from engineering to manufacturing, it is necessary to introduce a series of product interpretations which contain an interim introduction of technical parameters. The current automation of the product definition and the production process places manufacturing engineering in the center of CAD/CAM with the responsibility of communicating design data to the factory floor via a manufacturing model of the data. A close look at data management requirements for manufacturing engineering is necessary in order to establish the overall specifications for CADD output, CAM input, and CIM integration. The functions and issues associated with the orderly evolution of computer aided engineering and manufacturing are examined.
Scotti, Roberto; Pellegrino, Gerardo; Marchetti, Claudio; Corinaldesi, Guiseppe; Ciocca, Leonardo
2010-01-01
To test if using a CAD/CAM system might reduce the necessity of bone augmentation in patients with atrophic maxillary arches before implant therapy. Twenty male and female patients consecutively scheduled for bone augmentation of the jaw before implant surgery were included in this study, with a total of 29 jaws (maxillary and mandibular) to analyze for the implant-supported fixed prosthesis group and 19 maxillary arches for the implant-supported removable prosthesis group. NobelGuide System (Nobel Biocare), Autocad System (Autodesk), and routine manual CT measurements of available bone were used in this study. The total results of the mean values of the fixed prosthesis group plus the mean values of the removable prosthesis group showed a statistically significant difference between the NobelGuide intervention score and both manual (P = .004) and Autocad (P = .001) measurements. The NobelGuide System represents a viable diagnostic device to reduce the entity or avoid bone reconstructive surgery before implant placements in the atrophic maxilla and mandible.
Orchestration of carbohydrate processing for crassulacean acid metabolism
DOE Office of Scientific and Technical Information (OSTI.GOV)
Borland, Anne M.; Guo, Hao-Bo; Yang, Xiaohan
The production of phosphoenolpyruvate as a substrate for nocturnal CO 2 uptake represents a significant sink for carbohydrate in CAM plants which has to be balanced with the provisioning of carbohydrate for growth and maintenance. In starch-storing CAM species, diversification in chloroplast metabolite transporters, and the deployment of both phosphorolytic and hydrolytic routes of starch degradation accommodate a division of labour in directing C-skeletons towards nocturnal carboxylation or production of sucrose for growth. In soluble-sugar storing CAM plants, the vacuole plays a central role in managing carbon homeostasis. The molecular identities of various types of vacuolar sugar transporters have onlymore » been identified for C 3 species within the last 10 years. In conclusion, the recent availability of CAM genomes enables the identification of putative orthologues of vacuolar sugar transporters which represent strategic targets for orchestrating the diel provisioning of substrate for nocturnal carboxylation and growth.« less
Turbulent fluctuations and the excitation of Z Cam outbursts
NASA Astrophysics Data System (ADS)
Ross, Johnathan; Latter, Henrik N.
2017-09-01
Z Cam variables are a subclass of dwarf nova that lie near a global bifurcation between outbursting ('limit cycle') and non-outbursting ('standstill') states. It is believed that variations in the secondary star's mass-injection rate instigate transitions between the two regimes. In this paper, we explore an alternative trigger for these transitions: stochastic fluctuations in the disc's turbulent viscosity. We employ simple one-zone and global viscous models which, though inappropriate for detailed matching to observed light curves, clearly indicate that turbulent disc fluctuations induce outbursts when the system is sufficiently close to the global bifurcation point. While the models easily produce the observed 'outburst/dip' pairs exhibited by Z Cam and Nova-like variables, they struggle to generate long trains of outbursts. We conclude that mass transfer variability is the dominant physical process determining the overall Z Cam standstill/outburst pattern, but that viscous stochasticity provides an additional ingredient explaining some of the secondary features observed.
The Ca2+/Calmodulin/CaMKK2 Axis: Nature’s Metabolic CaMshaft
Marcelo, Kathrina L.; Means, Anthony R.; York, Brian
2016-01-01
Calcium (Ca2+) is an essential ligand that binds its primary intracellular receptor Calmodulin (CaM) to trigger a variety of downstream processes and pathways. Central to the actions of Ca2+/CaM is the activation of a highly conserved Ca2+/CaM kinase (CaMK) cascade, which amplifies Ca2+ signals through a series of subsequent phosphorylation events. Proper regulation of Ca2+ flux is necessary for whole-body metabolism and disruption of Ca2+ homeostasis has been linked to a variety of metabolic diseases. Herein, we provide a synthesis of recent advances that highlight the roles of the Ca2+/CaM kinase axis in key metabolic tissues. An appreciation of this information is critical in order to understand the mechanisms by which Ca2+/CaM-dependent signaling contributes to metabolic homeostasis and disease. PMID:27449752
Calmodulin point mutations affect Drosophila development and behavior.
Nelson, H B; Heiman, R G; Bolduc, C; Kovalick, G E; Whitley, P; Stern, M; Beckingham, K
1997-12-01
Calmodulin (CAM) is recognized as a major intermediary in intracellular calcium signaling, but as yet little is known of its role in developmental and behavioral processes. We have generated and studied mutations to the endogenous Cam gene of Drosophila melanogaster that change single amino acids within the protein coding region. One of these mutations produces a striking pupal lethal phenotype involving failure of head eversion. Various mutant combinations produce specific patterns of ectopic wing vein formation or melanotic scabs on the cuticle. Anaphase chromosome bridging is also seen as a maternal effect during the early embryonic nuclear divisions. In addition, specific behavioral defects such as poor climbing and flightlessness are detected among these mutants. Comparisons with other Drosophila mutant phenotypes suggests potential CAM targets that may mediate these developmental and behavioral effects, and analysis of the CAM crystal structure suggests the structural consequences of the individual mutations.
Calmodulin Point Mutations Affect Drosophila Development and Behavior
Nelson, H. B.; Heiman, R. G.; Bolduc, C.; Kovalick, G. E.; Whitley, P.; Stern, M.; Beckingham, K.
1997-01-01
Calmodulin (CAM) is recognized as a major intermediary in intracellular calcium signaling, but as yet little is known of its role in developmental and behavioral processes. We have generated and studied mutations to the endogenous Cam gene of Drosophila melanogaster that change single amino acids within the protein coding region. One of these mutations produces a striking pupal lethal phenotype involving failure of head eversion. Various mutant combinations produce specific patterns of ectopic wing vein formation or melanotic scabs on the cuticle. Anaphase chromosome bridging is also seen as a maternal effect during the early embryonic nuclear divisions. In addition, specific behavioral defects such as poor climbing and flightlessness are detected among these mutants. Comparisons with other Drosophila mutant phenotypes suggests potential CAM targets that may mediate these developmental and behavioral effects, and analysis of the CAM crystal structure suggests the structural consequences of the individual mutations. PMID:9409836
Orchestration of carbohydrate processing for crassulacean acid metabolism
Borland, Anne M.; Guo, Hao-Bo; Yang, Xiaohan; ...
2016-04-19
The production of phosphoenolpyruvate as a substrate for nocturnal CO 2 uptake represents a significant sink for carbohydrate in CAM plants which has to be balanced with the provisioning of carbohydrate for growth and maintenance. In starch-storing CAM species, diversification in chloroplast metabolite transporters, and the deployment of both phosphorolytic and hydrolytic routes of starch degradation accommodate a division of labour in directing C-skeletons towards nocturnal carboxylation or production of sucrose for growth. In soluble-sugar storing CAM plants, the vacuole plays a central role in managing carbon homeostasis. The molecular identities of various types of vacuolar sugar transporters have onlymore » been identified for C 3 species within the last 10 years. In conclusion, the recent availability of CAM genomes enables the identification of putative orthologues of vacuolar sugar transporters which represent strategic targets for orchestrating the diel provisioning of substrate for nocturnal carboxylation and growth.« less
Shinawi, Lana Ahmed
2017-01-01
Background The application of computer-aided design computer-aided manufacturing (CAD CAM) technology in the fabrication of complete dentures, offers numerous advantages as it provides optimum fit and eliminates polymerization shrinkage of the acrylic base. Additionally, the porosity and surface roughness of CAD CAM resins is less compared to conventionally processed resins which leads to a decrease in the adhesion of bacteria on the denture base, which is associated with many conditions including halitosis and aspiration pneumonia in elderly denture wearers. Aim To evaluate the influence of tooth brushing with dentifrices on CAD CAM resin blocks in terms of abrasion resistance, surface roughness and scanning electron photomicrography. Methods This experimental study was carried out at the Faculty of Dentistry of King Abdulaziz University during 2016. A total of 40 rectangular shaped polymerized CAD CAM resin samples were subjected to 40.000 and 60.000 brushing strokes under a 200-gram vertical load simulating three years of tooth brushing strokes using commercially available denture cleaning dentifrice. Data were analyzed by SPSS version 20, using descriptive statistics and ANOVA. Results ANOVA test revealed a statistical significant weight loss of CAD CAM acrylic resin denture base specimens following 40.000 and 60.000 brushing strokes as well as a statistical significant change (p=0.0.5) in the surface roughness following brushing. The CAD CAM resin samples SEM baseline imaging revealed a relatively smooth homogenous surface, but following 40,000 and 60,000 brushing strokes, imaging displayed the presence of small scratches on the surface. Conclusion CAD CAM resin displayed a homogenous surface initially with low surface roughness that was significantly affected following simulating three years of manual brushing, but despite the significant weight loss, the findings are within the clinically acceptable limits. PMID:28713496
Shinawi, Lana Ahmed
2017-05-01
The application of computer-aided design computer-aided manufacturing (CAD CAM) technology in the fabrication of complete dentures, offers numerous advantages as it provides optimum fit and eliminates polymerization shrinkage of the acrylic base. Additionally, the porosity and surface roughness of CAD CAM resins is less compared to conventionally processed resins which leads to a decrease in the adhesion of bacteria on the denture base, which is associated with many conditions including halitosis and aspiration pneumonia in elderly denture wearers. To evaluate the influence of tooth brushing with dentifrices on CAD CAM resin blocks in terms of abrasion resistance, surface roughness and scanning electron photomicrography. This experimental study was carried out at the Faculty of Dentistry of King Abdulaziz University during 2016. A total of 40 rectangular shaped polymerized CAD CAM resin samples were subjected to 40.000 and 60.000 brushing strokes under a 200-gram vertical load simulating three years of tooth brushing strokes using commercially available denture cleaning dentifrice. Data were analyzed by SPSS version 20, using descriptive statistics and ANOVA. ANOVA test revealed a statistical significant weight loss of CAD CAM acrylic resin denture base specimens following 40.000 and 60.000 brushing strokes as well as a statistical significant change (p=0.0.5) in the surface roughness following brushing. The CAD CAM resin samples SEM baseline imaging revealed a relatively smooth homogenous surface, but following 40,000 and 60,000 brushing strokes, imaging displayed the presence of small scratches on the surface. CAD CAM resin displayed a homogenous surface initially with low surface roughness that was significantly affected following simulating three years of manual brushing, but despite the significant weight loss, the findings are within the clinically acceptable limits.
Gilhare, Varsha Rani; Hirpurkar, S. D.; Kumar, Ashish; Naik, Surendra Kumar; Sahu, Tarini
2015-01-01
Aim: The objective of the present study was to examine pock forming ability of field strain and vaccine strain of fowl pox virus (FPV) in chorioallantoic membrane (CAM) of embryonated chicken eggs and its adaptation in chicken embryo fibroblast (CEF) cell culture. Materials and Methods: Dry scabs were collected from 25 affected birds in glycerin-saline and preserved at 4°C until processed. Virus was isolated in 10-day-old embryonated chicken eggs by dropped CAM method. The identity of the virus is confirmed by clinical findings of affected birds, pock morphology and histopathology of infected CAM. In addition one field isolate and vaccine strain of FPV was adapted to CEF cell culture. CEF cell culture was prepared from 9-day-old embryonated chicken eggs. Result: Clinical symptoms observed in affected birds include pox lesion on comb, wattle, eyelids and legs, no internal lesions were observed. All field isolates produced similar findings in CAM. Pocks produced by field isolates ranged from 3 mm to 5 mm at the third passage while initial passages edematous thickening and necrosis of CAM was observed. Pocks formed by lyophilized strain were ranges from 0.5 mm to 2.5 mm in diameter scattered all over the membrane at the first passage. Intra-cytoplasmic inclusion bodies are found on histopathology of CAM. At third passage level, the CEF inoculated with FPV showed characteristic cytopathic effect (CPE) included aggregation of cells, syncytia and plaque formation. Conclusion: FPV field isolates and vaccine strain produced distinct pock lesions on CAMs. Infected CAM showed intracytoplasmic inclusion bodies. The CEF inoculated with FPV field isolate as well as a vaccine strain showed characteristic CPE at third passage level. PMID:27047081
Gilhare, Varsha Rani; Hirpurkar, S D; Kumar, Ashish; Naik, Surendra Kumar; Sahu, Tarini
2015-03-01
The objective of the present study was to examine pock forming ability of field strain and vaccine strain of fowl pox virus (FPV) in chorioallantoic membrane (CAM) of embryonated chicken eggs and its adaptation in chicken embryo fibroblast (CEF) cell culture. Dry scabs were collected from 25 affected birds in glycerin-saline and preserved at 4°C until processed. Virus was isolated in 10-day-old embryonated chicken eggs by dropped CAM method. The identity of the virus is confirmed by clinical findings of affected birds, pock morphology and histopathology of infected CAM. In addition one field isolate and vaccine strain of FPV was adapted to CEF cell culture. CEF cell culture was prepared from 9-day-old embryonated chicken eggs. Clinical symptoms observed in affected birds include pox lesion on comb, wattle, eyelids and legs, no internal lesions were observed. All field isolates produced similar findings in CAM. Pocks produced by field isolates ranged from 3 mm to 5 mm at the third passage while initial passages edematous thickening and necrosis of CAM was observed. Pocks formed by lyophilized strain were ranges from 0.5 mm to 2.5 mm in diameter scattered all over the membrane at the first passage. Intra-cytoplasmic inclusion bodies are found on histopathology of CAM. At third passage level, the CEF inoculated with FPV showed characteristic cytopathic effect (CPE) included aggregation of cells, syncytia and plaque formation. FPV field isolates and vaccine strain produced distinct pock lesions on CAMs. Infected CAM showed intracytoplasmic inclusion bodies. The CEF inoculated with FPV field isolate as well as a vaccine strain showed characteristic CPE at third passage level.
Pourtsidis, Apostolos; Doganis, Dimitrios; Baka, Margarita; Varvoutsi, Maria; Bouhoutsou, Despina; Xatzi, Panagiota; Kosmidis, Helen
2015-01-01
Increasing numbers of children with cancer are using complementary and alternative medicine (CAM) therapies. Our aim was to estimate the rate of use, the beliefs of users and non-users and factors related with the use of CAM among Greek families. A self-reported questionnaire was given to parents of 184 children with cancer. We assessed the rate of use, types of CAM therapies and factors potentially associated with the use of CAM. Based on the 110 questionnaires which were completed (59.8% of the families), 23 families (21%) had used at least one complementary treatment. The most common forms were: spiritual healing/prayer/blessings 18/23 (78%), art therapies 4, dietary supplements 3, massage 3, homeopathy 2, and herbals 2. The reasons given for use included: making the child stronger 17/23 (48%, hope of stopping the cancerous process 11/23 (49%), and coping with side effects 6/23 (26%). Among the reasons given by the parents for not using CAM therapies the most common (84%) was the effective conventional treatment and, therefore, there was no need for CAM use. Another 24% reported that were unaware of these "alternative" and "complementary" therapies and a further 7% had considered using them but finally they didn't. In bivariate analysis, the use of CAM was not associated either with age, sex, nationality, education or occupation of the parents at the time of the survey, or with diagnosis, mode of therapy or age of the child at diagnosis. The use of CAM therapies by Greek families for their children with cancer does not appear to be very popular, although the experiences of those who did use them were generally positive.
NASA Astrophysics Data System (ADS)
Benedict, James J.; Medeiros, Brian; Clement, Amy C.; Pendergrass, Angeline G.
2017-06-01
Precipitation distributions and extremes play a fundamental role in shaping Earth's climate and yet are poorly represented in many global climate models. Here, a suite of idealized Community Atmosphere Model (CAM) aquaplanet simulations is examined to assess the aquaplanet's ability to reproduce hydroclimate statistics of real-Earth configurations and to investigate sensitivities of precipitation distributions and extremes to model physics, horizontal grid resolution, and ocean type. Little difference in precipitation statistics is found between aquaplanets using time-constant sea-surface temperatures and those implementing a slab ocean model with a 50 m mixed-layer depth. In contrast, CAM version 5.3 (CAM5.3) produces more time mean, zonally averaged precipitation than CAM version 4 (CAM4), while CAM4 generates significantly larger precipitation variance and frequencies of extremely intense precipitation events. The largest model configuration-based precipitation sensitivities relate to choice of horizontal grid resolution in the selected range 1-2°. Refining grid resolution has significant physics-dependent effects on tropical precipitation: for CAM4, time mean zonal mean precipitation increases along the Equator and the intertropical convergence zone (ITCZ) narrows, while for CAM5.3 precipitation decreases along the Equator and the twin branches of the ITCZ shift poleward. Increased grid resolution also reduces light precipitation frequencies and enhances extreme precipitation for both CAM4 and CAM5.3 resulting in better alignment with observational estimates. A discussion of the potential implications these hydrologic cycle sensitivities have on the interpretation of precipitation statistics in future climate projections is also presented.
The Hyper Suprime-Cam software pipeline
NASA Astrophysics Data System (ADS)
Bosch, James; Armstrong, Robert; Bickerton, Steven; Furusawa, Hisanori; Ikeda, Hiroyuki; Koike, Michitaro; Lupton, Robert; Mineo, Sogo; Price, Paul; Takata, Tadafumi; Tanaka, Masayuki; Yasuda, Naoki; AlSayyad, Yusra; Becker, Andrew C.; Coulton, William; Coupon, Jean; Garmilla, Jose; Huang, Song; Krughoff, K. Simon; Lang, Dustin; Leauthaud, Alexie; Lim, Kian-Tat; Lust, Nate B.; MacArthur, Lauren A.; Mandelbaum, Rachel; Miyatake, Hironao; Miyazaki, Satoshi; Murata, Ryoma; More, Surhud; Okura, Yuki; Owen, Russell; Swinbank, John D.; Strauss, Michael A.; Yamada, Yoshihiko; Yamanoi, Hitomi
2018-01-01
In this paper, we describe the optical imaging data processing pipeline developed for the Subaru Telescope's Hyper Suprime-Cam (HSC) instrument. The HSC Pipeline builds on the prototype pipeline being developed by the Large Synoptic Survey Telescope's Data Management system, adding customizations for HSC, large-scale processing capabilities, and novel algorithms that have since been reincorporated into the LSST codebase. While designed primarily to reduce HSC Subaru Strategic Program (SSP) data, it is also the recommended pipeline for reducing general-observer HSC data. The HSC pipeline includes high-level processing steps that generate coadded images and science-ready catalogs as well as low-level detrending and image characterizations.
Implementation of online suicide-specific training for VA providers.
Marshall, Elizabeth; York, Janet; Magruder, Kathryn; Yeager, Derik; Knapp, Rebecca; De Santis, Mark L; Burriss, Louisa; Mauldin, Mary; Sulkowski, Stan; Pope, Charlene; Jobes, David A
2014-10-01
Due to the gap in suicide-specific intervention training for mental health students and professionals, e-learning is one solution to improving provider skills in the Veterans Affairs (VA) health system. This study focused on the development and evaluation of an equivalent e-learning alternative to the Collaborative Assessment and Management of Suicidality (CAMS) in-person training approach at a Veteran Health Affairs medical center. The study used a multicenter, randomized, cluster, and three group design. the development of e-CAMS was an iterative process and included pilot testing. Eligible and consenting mental health providers, who completed a CAMS pre-survey, were randomized. Provider satisfaction was assessed using the standard VA evaluation of training consisting of 20 items. Two post training focus groups, divided by learning conditions, were conducted to assess practice adoption using a protocol focused on experiences with training and delivery of CAMS. A total of 215 providers in five sites were randomized to three conditions: 69 to e-learning, 70 to in-person, 76 to the control. The providers were primarily female, Caucasian, midlife providers. Based on frequency scores of satisfaction items, both learning groups rated the trainings positively. In focus groups representing divided by learning conditions, participants described positive reactions to CAMS training and similar individual and institutional barriers to full implementation of CAMS. This is the first evaluation study of a suicide-specific e-learning training within the VA. The e-CAMS appears equivalent to the in-person CAMS in terms of provider satisfaction with training and practice adoption, consistent with other comparisons of training deliveries across specialty areas. Additional evaluation of provider confidence and adoption and patient outcomes is in progress. The e-CAMS has the potential to provide ongoing training for VA and military mental health providers and serve as a tutorial for psychiatrists in preparation for specialty boards.
Tilmes, S.; Lamarque, J. -F.; Emmons, L. K.; ...
2015-01-01
The Community Atmosphere Model (CAM), version 5, is now coupled to extensive tropospheric and stratospheric chemistry, called CAM5-chem, and is available in addition to CAM4-chem in the Community Earth System Model (CESM) version 1.2. The main focus of this paper is to compare the performance of configurations with internally derived "free running" (FR) meteorology and "specified dynamics" (SD) against observations from surface, aircraft, and satellite, as well as understand the origin of the identified differences. We focus on the representation of aerosols and chemistry. All model configurations reproduce tropospheric ozone for most regions based on in situ and satellite observations.more » However, shortcomings exist in the representation of ozone precursors and aerosols. Tropospheric ozone in all model configurations agrees for the most part with ozonesondes and satellite observations in the tropics and the Northern Hemisphere within the variability of the observations. Southern hemispheric tropospheric ozone is consistently underestimated by up to 25%. Differences in convection and stratosphere to troposphere exchange processes are mostly responsible for differences in ozone in the different model configurations. Carbon monoxide (CO) and other volatile organic compounds are largely underestimated in Northern Hemisphere mid-latitudes based on satellite and aircraft observations. Nitrogen oxides (NO x) are biased low in the free tropical troposphere, whereas peroxyacetyl nitrate (PAN) is overestimated in particular in high northern latitudes. The present-day methane lifetime estimates are compared among the different model configurations. These range between 7.8 years in the SD configuration of CAM5-chem and 8.8 years in the FR configuration of CAM4-chem and are therefore underestimated compared to observational estimations. We find that differences in tropospheric aerosol surface area between CAM4 and CAM5 play an important role in controlling the burden of the tropical tropospheric hydroxyl radical (OH), which causes differences in tropical methane lifetime of about half a year between CAM4-chem and CAM5-chem. In addition, different distributions of NO x from lightning explain about half of the difference between SD and FR model versions in both CAM4-chem and CAM5-chem. Remaining differences in the tropical OH burden are due to enhanced tropical ozone burden in SD configurations compared to the FR versions, which are not only caused by differences in chemical production or loss but also by transport and mixing. For future studies, we recommend the use of CAM5-chem configurations, due to improved aerosol description and inclusion of aerosol–cloud interactions. However, smaller tropospheric surface area density in the current version of CAM5-chem compared to CAM4-chem results in larger oxidizing capacity in the troposphere and therefore a shorter methane lifetime.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tilmes, S.; Lamarque, J. -F.; Emmons, L. K.
The Community Atmosphere Model (CAM), version 5, is now coupled to extensive tropospheric and stratospheric chemistry, called CAM5-chem, and is available in addition to CAM4-chem in the Community Earth System Model (CESM) version 1.2. The main focus of this paper is to compare the performance of configurations with internally derived "free running" (FR) meteorology and "specified dynamics" (SD) against observations from surface, aircraft, and satellite, as well as understand the origin of the identified differences. We focus on the representation of aerosols and chemistry. All model configurations reproduce tropospheric ozone for most regions based on in situ and satellite observations.more » However, shortcomings exist in the representation of ozone precursors and aerosols. Tropospheric ozone in all model configurations agrees for the most part with ozonesondes and satellite observations in the tropics and the Northern Hemisphere within the variability of the observations. Southern hemispheric tropospheric ozone is consistently underestimated by up to 25%. Differences in convection and stratosphere to troposphere exchange processes are mostly responsible for differences in ozone in the different model configurations. Carbon monoxide (CO) and other volatile organic compounds are largely underestimated in Northern Hemisphere mid-latitudes based on satellite and aircraft observations. Nitrogen oxides (NO x) are biased low in the free tropical troposphere, whereas peroxyacetyl nitrate (PAN) is overestimated in particular in high northern latitudes. The present-day methane lifetime estimates are compared among the different model configurations. These range between 7.8 years in the SD configuration of CAM5-chem and 8.8 years in the FR configuration of CAM4-chem and are therefore underestimated compared to observational estimations. We find that differences in tropospheric aerosol surface area between CAM4 and CAM5 play an important role in controlling the burden of the tropical tropospheric hydroxyl radical (OH), which causes differences in tropical methane lifetime of about half a year between CAM4-chem and CAM5-chem. In addition, different distributions of NO x from lightning explain about half of the difference between SD and FR model versions in both CAM4-chem and CAM5-chem. Remaining differences in the tropical OH burden are due to enhanced tropical ozone burden in SD configurations compared to the FR versions, which are not only caused by differences in chemical production or loss but also by transport and mixing. For future studies, we recommend the use of CAM5-chem configurations, due to improved aerosol description and inclusion of aerosol–cloud interactions. However, smaller tropospheric surface area density in the current version of CAM5-chem compared to CAM4-chem results in larger oxidizing capacity in the troposphere and therefore a shorter methane lifetime.« less
Tarsitano, A; Ciocca, L; Cipriani, R; Scotti, R; Marchetti, C
2015-06-01
Free fibula flap is routinely used for mandibular reconstructions. For contouring the flap, multiple osteotomies should be shaped to reproduce the native mandibular contour. The bone segments should be fixed using a reconstructive plate. This plate is usually manually bent by the surgeon during surgery. This method is efficient, but during reconstruction it is complicated to reproduce the complex 3D conformation of the mandible and recreate a normal morphology with a mandibular profile as similar as possible to the original; any aberration in its structural alignment may lead to aesthetic and function alterations due to malocclusion or temporomandibular disorders. In order to achieve better morphological and functional outcomes, we have performed a customised flap harvest using cutting guides. This study demonstrates how we have performed customised mandibular reconstruction using CAD-CAM fibular cutting guides in 20 patients undergoing oncological segmental resection.
JunoCam Images of Jupiter: A Juno Citizen Science Experiment
NASA Astrophysics Data System (ADS)
Hansen, Candice; Ravine, Michael; Bolton, Scott; Caplinger, Mike; Eichstadt, Gerald; Jensen, Elsa; Momary, Thomas W.; Orton, Glenn S.; Rogers, John
2017-10-01
The Juno mission to Jupiter carries a visible imager on its payload primarily for outreach. The vision of JunoCam’s outreach plan was for the public to participate in, not just observe, a science investigation. Four webpage components were developed for uploading and downloading comments and images, following the steps a traditional imaging team would do: Planning, Discussion, Voting, and Processing, hosted at https://missionjuno.swri.edu/junocam. Lightly processed and raw JunoCam data are posted. JunoCam images through broadband red, green and blue filters and a narrowband methane filter centered at 889 nm mounted directly on the detector. JunoCam is a push-frame imager with a 58 deg wide field of view covering a 1600 pixel width, and builds the second dimension of the image as the spacecraft rotates. This design enables capture of the entire pole of Jupiter in a single image at low emission angle when Juno is ~1 hour from perijove (closest approach). At perijove the wide field of view images are high-resolution while still capturing entire storms, e.g. the Great Red Spot. The public is invited to download JunoCam images, process them, and then upload their products. Over 2000 images have been uploaded to the JunoCam public image gallery. Contributions range from scientific quality to artful whimsy. Artistic works are inspired by Van Gogh and Monet. Works of whimsy include how Jupiter might look through the viewport of the Millennium Falcon, or to an angel perched on a lookout, or through a kaleidoscope. Citizen scientists have also engaged in serious quantitative analysis of the images, mapping images to storms and disruptions of the belts and zones that have been tracked from the earth. They are developing a phase function for Jupiter that allows the images to be flattened from the subsolar point to the terminator, and studying high hazes. Citizen scientists are also developing time-lapse movies, measuring wind flow, tracking circulation patterns in the circumpolar cyclones, and looking for lightning flashes. This effort has engaged the public, with a range of personal interests and considerable artistic and analytic talents. In return, we count our diverse public as partners in this endeavor.
2014-01-01
Background. Evidence rankings do not consider equally internal (IV), external (EV), and model validity (MV) for clinical studies including complementary and alternative medicine/integrative medicine (CAM/IM) research. This paper describe this model and offers an EV assessment tool (EVAT©) for weighing studies according to EV and MV in addition to IV. Methods. An abbreviated systematic review methodology was employed to search, assemble, and evaluate the literature that has been published on EV/MV criteria. Standard databases were searched for keywords relating to EV, MV, and bias-scoring from inception to Jan 2013. Tools identified and concepts described were pooled to assemble a robust tool for evaluating these quality criteria. Results. This study assembled a streamlined, objective tool to incorporate for the evaluation of quality of EV/MV research that is more sensitive to CAM/IM research. Conclusion. Improved reporting on EV can help produce and provide information that will help guide policy makers, public health researchers, and other scientists in their selection, development, and improvement in their research-tested intervention. Overall, clinical studies with high EV have the potential to provide the most useful information about “real-world” consequences of health interventions. It is hoped that this novel tool which considers IV, EV, and MV on equal footing will better guide clinical decision making. PMID:24734111
NASA Astrophysics Data System (ADS)
Liu, X.; Zhang, M.; Zhang, D.; Wang, Z.; Wang, Y.
2017-12-01
Mixed-phase clouds are persistently observed over the Arctic and the phase partitioning between cloud liquid and ice hydrometeors in mixed-phase clouds has important impacts on the surface energy budget and Arctic climate. In this study, we test the NCAR Community Atmosphere Model Version 5 (CAM5) with the single-column and weather forecast configurations and evaluate the model performance against observation data from the DOE Atmospheric Radiation Measurement (ARM) Program's M-PACE field campaign in October 2004 and long-term ground-based multi-sensor remote sensing measurements. Like most global climate models, we find that CAM5 also poorly simulates the phase partitioning in mixed-phase clouds by significantly underestimating the cloud liquid water content. Assuming pocket structures in the distribution of cloud liquid and ice in mixed-phase clouds as suggested by in situ observations provides a plausible solution to improve the model performance by reducing the Wegner-Bergeron-Findeisen (WBF) process rate. In this study, the modification of the WBF process in the CAM5 model has been achieved with applying a stochastic perturbation to the time scale of the WBF process relevant to both ice and snow to account for the heterogeneous mixture of cloud liquid and ice. Our results show that this modification of WBF process improves the modeled phase partitioning in the mixed-phase clouds. The seasonal variation of mixed-phase cloud properties is also better reproduced in the model in comparison with the long-term ground-based remote sensing observations. Furthermore, the phase partitioning is insensitive to the reassignment time step of perturbations.
Willson, Stephanie; Stussman, Barbara; Maitland, Aaron; Nahin, Richard L
2009-12-01
The aim of this study was to assess the construct validity of survey questions about the use of herbal and other nonvitamin/nonmineral dietary supplements. We conducted one-on-one, in-depth cognitive interviews with 32 respondents to test questions from the complementary and alternative medicine (CAM) supplement for the 2007 National Health Interview Survey. Respondents were sampled purposively according to their use of CAM. Interviewers probed respondents for their understanding of the questions, and analysis was guided by grounded theory, an approach that generates explanations of response error that are closely tied to the empirical data. We found two sources of misinterpretation of CAM questions. First, some respondents did not have any pre-established definition of what constitutes an herbal supplement while others had interpretations that did not match the intended definitions. These problems are common to many survey questions. However, a second finding is that misinterpretation also arose when respondents incorporated notions of self-concept into the act of taking "natural herbs," and answered based on their understanding of this image rather than on actual behavior. There are several sources of misinterpretation of CAM questions. One of the most important sources is whether or not the respondent has created a concept of self-image that includes the use of herbal supplements. Common questionnaire design techniques such as providing definitions to respondents will not help to eliminate misinterpretation due to self-image. We found that careful question wording that does not evoke definitions of self, combined with visual aids that narrow the focus of the questions, can lead to more accurate answers.
JunoCam: Science and Outreach Opportunities with Juno
NASA Astrophysics Data System (ADS)
Hansen, C. J.; Orton, G. S.
2015-12-01
JunoCam is a visible imager on the Juno spacecraft en route to Jupiter. Although the primary role of the camera is for outreach, science objectives will be addressed too. JunoCam is a wide angle camera (58 deg field of view) with 4 color filters: red, green and blue (RGB) and methane at 889 nm. Juno's elliptical polar orbit will offer unique views of Jupiter's polar regions with a spatial scale of ~50 km/pixel. The polar vortex, polar cloud morphology, and winds will be investigated. RGB color mages of the aurora will be acquired. Stereo images and images taken with the methane filter will allow us to estimate cloudtop heights. Resolution exceeds that of Cassini about an hour from closest approach and at closest approach images will have a spatial scale of ~3 km/pixel. JunoCam is a push-frame imager on a rotating spacecraft. The use of time-delayed integration takes advantage of the spacecraft spin to build up signal. JunoCam will acquire limb-to-limb views of Jupiter during a spacecraft rotation, and has the possibility of acquiring images of the rings from in-between Jupiter and the inner edge of the rings. Galilean satellite views will be fairly distant but some images will be acquired. Small ring moons Metis and Adrastea will also be imaged. The theme of our outreach is "science in a fish bowl", with an invitation to the science community and the public to participate. Amateur astronomers will supply their ground-based images for planning, so that we can predict when prominent atmospheric features will be visible. With the aid of professional astronomers observing at infrared wavelengths, we'll predict when hot spots will be visible to JunoCam. Amateur image processing enthusiasts are prepared to create image products. Between the planning and products will be the decision-making on what images to take when and why. We invite our colleagues to propose science questions for JunoCam to address, and to be part of the participatory process of deciding how to use our resources and scientifically analyze the data.
75 FR 25210 - Procurement List Proposed Additions and Deletions
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-07
...-9276--Multi Cam NSN: 8415-01-579-9272--Multi Cam NSN: 8415-01-579-9267--Multi Cam NSN: 8415-01-579-9260--Multi Cam NSN: 8415-01-579-9219--Multi Cam NSN: 8415-01-579-9210--Multi Cam NSN: 8415-01-579-9197--Multi Cam NSN: 8415-01-579-9189--Multi Cam NSN: 8415-01-579-9182--Multi Cam NSN: 8415-01-579-9175--Multi Cam...
Cantu, Theresa M.; Bowden, John A.; Scott, Jacob; Pérez-Viscasillas, Jimena B.; Huncik, Kevin; Guillette, Matthew P.; Guillette, Louis J.
2017-01-01
Eicosanoids are signaling lipids known to regulate several physiological processes in the mammalian placenta, including the initiation of parturition. Though all amniotes construct similar extraembryonic membranes during development, the composition and function of eicosanoids in extraembryonic membranes of oviparous reptiles is largely unknown. The majority of effort placed in eicosanoid investigations is typically targeted toward defining the role of specific compounds in disease etiology; however, comprehensive characterization of several pathways in eicosanoid synthesis during development is also needed to better understand the complex role of these lipids in comparative species. To this end, we have examined the chorioallantoic membrane (CAM) of the American alligator (Alligator mississippiensis) and domestic chicken (Gallus gallus) during development. Previously, our lab has demonstrated that the CAM of several oviparous species shared conserved steroidogenic activity, a feature originally attributed to mammalian amniotes. To further explore this, we have developed a liquid chromatography/tandem mass spectrometry method that is used here to quantify multiple eicosanoids in the CAM of two oviparous species at different stages of development. We identified 18 eicosanoids in the alligator CAM; the cyclooxygenase (COX) pathway showed the largest increase from early development to later development in the alligator CAM. Similarly, the chicken CAM had an increase in COX products and COX activity, which supports the LC-MS/MS analyses. Jointly, our findings indicate that the CAM tissue of an oviparous species is capable of eicosanoid synthesis, which expands our knowledge of placental evolution and introduces the possibility of future comparative models of placental function. PMID:27401262
Design and fabrication of complete dentures using CAD/CAM technology
Han, Weili; Li, Yanfeng; Zhang, Yue; lv, Yuan; Zhang, Ying; Hu, Ping; Liu, Huanyue; Ma, Zheng; Shen, Yi
2017-01-01
Abstract The aim of the study was to test the feasibility of using commercially available computer-aided design and computer-aided manufacturing (CAD/CAM) technology including 3Shape Dental System 2013 trial version, WIELAND V2.0.049 and WIELAND ZENOTEC T1 milling machine to design and fabricate complete dentures. The modeling process of full denture available in the trial version of 3Shape Dental System 2013 was used to design virtual complete dentures on the basis of 3-dimensional (3D) digital edentulous models generated from the physical models. The virtual complete dentures designed were exported to CAM software of WIELAND V2.0.049. A WIELAND ZENOTEC T1 milling machine controlled by the CAM software was used to fabricate physical dentitions and baseplates by milling acrylic resin composite plates. The physical dentitions were bonded to the corresponding baseplates to form the maxillary and mandibular complete dentures. Virtual complete dentures were successfully designed using the software through several steps including generation of 3D digital edentulous models, model analysis, arrangement of artificial teeth, trimming relief area, and occlusal adjustment. Physical dentitions and baseplates were successfully fabricated according to the designed virtual complete dentures using milling machine controlled by a CAM software. Bonding physical dentitions to the corresponding baseplates generated the final physical complete dentures. Our study demonstrated that complete dentures could be successfully designed and fabricated by using CAD/CAM. PMID:28072686
Jayme, Sérgio J; Muglia, Valdir A; de Oliveira, Rafael R; Novaes, Arthur B Júnior
2008-01-01
Immediate loading of dental implants shortens the treatment time and makes it possible to give the patient an esthetic appearance throughout the treatment period. Placement of dental implants requires precise planning that accounts for anatomic limitations and restorative goals. Diagnosis can be made with the assistance of computerized tomographic scanning, but transfer of planning to the surgical field is limited. Recently, novel CAD/CAM techniques such as stereolithographic rapid prototyping have been developed to build surgical guides in an attempt to improve precision of implant placement. The aim of this case report was to show a modified surgical template used throughout implant placement as an alternative to a conventional surgical guide.
SenseCam: A new tool for memory rehabilitation?
Dubourg, L; Silva, A R; Fitamen, C; Moulin, C J A; Souchay, C
2016-12-01
The emergence of life-logging technologies has led neuropsychologist to focus on understanding how this new technology could help patients with memory disorders. Despite the growing number of studies using life-logging technologies, a theoretical framework supporting its effectiveness is lacking. This review focuses on the use of life-logging in the context of memory rehabilitation, particularly the use of SenseCam, a wearable camera allowing passive image capture. In our opinion, reviewing SenseCam images can be effective for memory rehabilitation only if it provides more than an assessment of prior occurrence in ways that reinstates previous thoughts, feelings and sensory information, thus stimulating recollection. Considering the fact that, in memory impairment, self-initiated processes are impaired, we propose that the environmental support hypothesis can explain the value of SenseCam for memory retrieval. Twenty-five research studies were selected for this review and despite the general acceptance of the value of SenseCam as a memory technique, only a small number of studies focused on recollection. We discuss the usability of this tool to improve episodic memory and in particular, recollection. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Krug, Klaus-Peter; Knauber, Andreas W; Nothdurft, Frank P
2015-03-01
The aim of this study was to investigate the fracture behavior of metal-ceramic bridges with frameworks from cobalt-chromium-molybdenum (CoCrMo), which are manufactured using conventional casting or a new computer-aided design/computer-aided manufacturing (CAD/CAM) milling and sintering technique. A total of 32 metal-ceramic fixed dental prostheses (FDPs), which are based on a nonprecious metal framework, was produced using a conventional casting process (n = 16) or a new CAD/CAM milling and sintering process (n = 16). Eight unveneered frameworks were manufactured using each of the techniques. After thermal and mechanical aging of half of the restorations, all samples were subjected to a static loading test in a universal testing machine, in which acoustic emission monitoring was performed. Three different critical forces were revealed: the fracture force (F max), the force at the first reduction in force (F decr1), and the force at the critical acoustic event (F acoust1). With the exception of the veneered restorations with cast or sintered metal frameworks without artificial aging, which presented a statistically significant but slightly different F max, no statistically significant differences between cast and CAD/CAM sintered and milled FDPs were detected. Thermal and mechanical loading did not significantly affect the resulting forces. Cast and CAD/CAM milled and sintered metal-ceramic bridges were determined to be comparable with respect to the fracture behavior. FDPs based on CAD/CAM milled and sintered frameworks may be an applicable and less technique-sensitive alternative to frameworks that are based on conventionally cast frameworks.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stern, S. Alan; Ennico, Kimberly; Gladstone, G. Randall
This collection contains two articles, "NASA's New Horizons Mission to Pluto" and the "Diversity of Chemistry and Geologic Processes Observed by the MSL/Chem Cam Laser Instrument in Gale Crater, Mars". These highlights describe how New Horizons came to be, how the spacecraft got to Pluto, and how the findings are challenging our understanding of ice worlds in the outer solar system; and the ChemCam, one of ten instrument packages on board the rover.
Stern, S. Alan; Ennico, Kimberly; Gladstone, G. Randall; ...
2016-04-01
This collection contains two articles, "NASA's New Horizons Mission to Pluto" and the "Diversity of Chemistry and Geologic Processes Observed by the MSL/Chem Cam Laser Instrument in Gale Crater, Mars". These highlights describe how New Horizons came to be, how the spacecraft got to Pluto, and how the findings are challenging our understanding of ice worlds in the outer solar system; and the ChemCam, one of ten instrument packages on board the rover.
Investigation of roughing machining simulation by using visual basic programming in NX CAM system
NASA Astrophysics Data System (ADS)
Hafiz Mohamad, Mohamad; Nafis Osman Zahid, Muhammed
2018-03-01
This paper outlines a simulation study to investigate the characteristic of roughing machining simulation in 4th axis milling processes by utilizing visual basic programming in NX CAM systems. The selection and optimization of cutting orientation in rough milling operation is critical in 4th axis machining. The main purpose of roughing operation is to approximately shape the machined parts into finished form by removing the bulk of material from workpieces. In this paper, the simulations are executed by manipulating a set of different cutting orientation to generate estimated volume removed from the machine parts. The cutting orientation with high volume removal is denoted as an optimum value and chosen to execute a roughing operation. In order to run the simulation, customized software is developed to assist the routines. Operations build-up instructions in NX CAM interface are translated into programming codes via advanced tool available in the Visual Basic Studio. The codes is customized and equipped with decision making tools to run and control the simulations. It permits the integration with any independent program files to execute specific operations. This paper aims to discuss about the simulation program and identifies optimum cutting orientations for roughing processes. The output of this study will broaden up the simulation routines performed in NX CAM systems.
2017-06-29
JunoCam images aren't just for art and science -- sometimes they are processed to bring a chuckle. This image, processed by citizen scientist Jason Major, is titled "Jovey McJupiterface." By rotating the image 180 degrees and orienting it from south up, two white oval storms turn into eyeballs, and the "face" of Jupiter is revealed. The original image was acquired by JunoCam on NASA's Juno spacecraft on May 19, 2017 at 11:20 a.m. PT (2: 20 p.m. ET) from an altitude of 12,075 miles (19,433 kilometers). https://photojournal.jpl.nasa.gov/catalog/PIA21394
The Hyper Suprime-Cam software pipeline
Bosch, James; Armstrong, Robert; Bickerton, Steven; ...
2017-10-12
Here in this article, we describe the optical imaging data processing pipeline developed for the Subaru Telescope’s Hyper Suprime-Cam (HSC) instrument. The HSC Pipeline builds on the prototype pipeline being developed by the Large Synoptic Survey Telescope’s Data Management system, adding customizations for HSC, large-scale processing capabilities, and novel algorithms that have since been reincorporated into the LSST codebase. While designed primarily to reduce HSC Subaru Strategic Program (SSP) data, it is also the recommended pipeline for reducing general-observer HSC data. The HSC pipeline includes high-level processing steps that generate coadded images and science-ready catalogs as well as low-level detrendingmore » and image characterizations.« less
The Hyper Suprime-Cam software pipeline
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bosch, James; Armstrong, Robert; Bickerton, Steven
Here in this article, we describe the optical imaging data processing pipeline developed for the Subaru Telescope’s Hyper Suprime-Cam (HSC) instrument. The HSC Pipeline builds on the prototype pipeline being developed by the Large Synoptic Survey Telescope’s Data Management system, adding customizations for HSC, large-scale processing capabilities, and novel algorithms that have since been reincorporated into the LSST codebase. While designed primarily to reduce HSC Subaru Strategic Program (SSP) data, it is also the recommended pipeline for reducing general-observer HSC data. The HSC pipeline includes high-level processing steps that generate coadded images and science-ready catalogs as well as low-level detrendingmore » and image characterizations.« less
Testing cloud microphysics parameterizations in NCAR CAM5 with ISDAC and M-PACE observations
NASA Astrophysics Data System (ADS)
Liu, Xiaohong; Xie, Shaocheng; Boyle, James; Klein, Stephen A.; Shi, Xiangjun; Wang, Zhien; Lin, Wuyin; Ghan, Steven J.; Earle, Michael; Liu, Peter S. K.; Zelenyuk, Alla
2011-01-01
Arctic clouds simulated by the National Center for Atmospheric Research (NCAR) Community Atmospheric Model version 5 (CAM5) are evaluated with observations from the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Indirect and Semi-Direct Aerosol Campaign (ISDAC) and Mixed-Phase Arctic Cloud Experiment (M-PACE), which were conducted at its North Slope of Alaska site in April 2008 and October 2004, respectively. Model forecasts for the Arctic spring and fall seasons performed under the Cloud-Associated Parameterizations Testbed framework generally reproduce the spatial distributions of cloud fraction for single-layer boundary-layer mixed-phase stratocumulus and multilayer or deep frontal clouds. However, for low-level stratocumulus, the model significantly underestimates the observed cloud liquid water content in both seasons. As a result, CAM5 significantly underestimates the surface downward longwave radiative fluxes by 20-40 W m-2. Introducing a new ice nucleation parameterization slightly improves the model performance for low-level mixed-phase clouds by increasing cloud liquid water content through the reduction of the conversion rate from cloud liquid to ice by the Wegener-Bergeron-Findeisen process. The CAM5 single-column model testing shows that changing the instantaneous freezing temperature of rain to form snow from -5°C to -40°C causes a large increase in modeled cloud liquid water content through the slowing down of cloud liquid and rain-related processes (e.g., autoconversion of cloud liquid to rain). The underestimation of aerosol concentrations in CAM5 in the Arctic also plays an important role in the low bias of cloud liquid water in the single-layer mixed-phase clouds. In addition, numerical issues related to the coupling of model physics and time stepping in CAM5 are responsible for the model biases and will be explored in future studies.
Use of complementary and alternative medicine by lymphoma survivors in South Korea.
Kim, Kisook; Kim, Soo Hyun; Ok, Oh Nam; Kim, Im-Ryung; Lee, Suyeon; Kim, So Hee; Kim, Won Seog; Ryu, Min-Hee; Lee, Moon Hee
2018-04-01
We aimed to examine the experience of complementary and alternative medicine (CAM) use and its association with health-related quality of life (HRQOL) in lymphoma survivors in South Korea. The participants were 869 lymphoma survivors from three hospitals in South Korea, all diagnosed with lymphoma at least 24 months prior to participation. Self-reported questionnaires were used to assess CAM use. The questionnaire addressed types of CAM used, sources of information about CAM, reason for CAM use, satisfaction with CAM use, discussion of CAM use with doctors, experience of side effects, costs of CAM use, and intentions to continue using CAM. HRQOL was measured with the EORTC QLQ-C30. Of the 869 participants, 42.2% had experience using CAM, and there were statistically significant differences among CAM users and non-users in terms of sex, religion, and time since diagnosis. A special diet (e.g., ginseng, chitosan, mixed cereals) was the most commonly used type of CAM, and most CAM users (82.1%) were satisfied with their CAM use. Most CAM users (77.5%) did not discuss the use of CAM with their doctors, and only 9.2% reported any side effects from CAM. CAM users showed significantly lower HRQOL scores than did non-users. A significant number of lymphoma survivors in Korea have used CAM, and most CAM users are satisfied with their CAM use. Oncology nurses should be aware of the range of CAM use among patients and reflect their responses in their treatment and/or follow-up care. Copyright © 2018 Elsevier Ltd. All rights reserved.
Madariaga-Mazón, Abraham; González-Andrade, Martín; González, María Del Carmen; Glenn, Anthony E; Cerda-García-Rojas, Carlos M; Mata, Rachel
2013-08-23
Bioassay-guided fractionation of an extract prepared from the culture medium and mycelium of Purpureocillium lilacinum allowed the isolation of two calmodulin (CaM) inhibitors, namely, acremoxanthone C (1) and acremonidin A (2). The absolute configuration of 1 was established as 2R, 3R, 1'S, 11'S, and 14'R through extensive NMR spectroscopy and molecular modeling calculations at the DFT B3LYP/DGDZVP level, which included the comparison between theoretical and experimental specific rotation, ³J(C,H), and ³J(H,H) values. Compounds 1 and 2 bind to the human calmodulin (hCaM) biosensor hCaM M124C-mBBr, with dissociation constants (Kd) of 18.25 and 19.40 nM, respectively, 70-fold higher than that of chlorpromazine (Kd = 1.24 μM), used as positive control. Docking analysis using AutoDock 4.2 predicted that 1 and 2 bind to CaM at a similar site to that which KAR-2 binds, which is unusual. Furthermore, a novel, sensible, and specific fluorescent biosensor of hCaM, i.e., hCaM T110C-mBBr, was constructed; this device is labeled at a site where classical inhibitors do not interact and was successfully applied to measure the interaction of 1 with CaM. This is the first report of xanthone-anthraquinone heterodimers in species of Paecilomyces or Purpureocillium genera.
NASA Astrophysics Data System (ADS)
Xu, Kuan-Man; Cheng, Anning
2014-05-01
A high-resolution cloud-resolving model (CRM) embedded in a general circulation model (GCM) is an attractive alternative for climate modeling because it replaces all traditional cloud parameterizations and explicitly simulates cloud physical processes in each grid column of the GCM. Such an approach is called "Multiscale Modeling Framework." MMF still needs to parameterize the subgrid-scale (SGS) processes associated with clouds and large turbulent eddies because circulations associated with planetary boundary layer (PBL) and in-cloud turbulence are unresolved by CRMs with horizontal grid sizes on the order of a few kilometers. A third-order turbulence closure (IPHOC) has been implemented in the CRM component of the super-parameterized Community Atmosphere Model (SPCAM). IPHOC is used to predict (or diagnose) fractional cloudiness and the variability of temperature and water vapor at scales that are not resolved on the CRM's grid. This model has produced promised results, especially for low-level cloud climatology, seasonal variations and diurnal variations (Cheng and Xu 2011, 2013a, b; Xu and Cheng 2013a, b). Because of the enormous computational cost of SPCAM-IPHOC, which is 400 times of a conventional CAM, we decided to bypass the CRM and implement the IPHOC directly to CAM version 5 (CAM5). IPHOC replaces the PBL/stratocumulus, shallow convection, and cloud macrophysics parameterizations in CAM5. Since there are large discrepancies in the spatial and temporal scales between CRM and CAM5, IPHOC used in CAM5 has to be modified from that used in SPCAM. In particular, we diagnose all second- and third-order moments except for the fluxes. These prognostic and diagnostic moments are used to select a double-Gaussian probability density function to describe the SGS variability. We also incorporate a diagnostic PBL height parameterization to represent the strong inversion above PBL. The goal of this study is to compare the simulation of the climatology from these three models (CAM5, CAM5-IPHOC and SPCAM-IPHOC), with emphasis on low-level clouds and precipitation. Detailed comparisons of scatter diagrams among the monthly-mean low-level cloudiness, PBL height, surface relative humidity and lower tropospheric stability (LTS) reveal the relative strengths and weaknesses for five coastal low-cloud regions among the three models. Observations from CloudSat and CALIPSO and ECMWF Interim reanalysis are used as the truths for the comparisons. We found that the standard CAM5 underestimates cloudiness and produces small cloud fractions at low PBL heights that contradict with observations. CAM5-IPHOC tends to overestimate low clouds but the ranges of LTS and PBL height variations are most realistic. SPCAM-IPHOC seems to produce most realistic results with relatively consistent results from one region to another. Further comparisons with other atmospheric environmental variables will be helpful to reveal the causes of model deficiencies so that SPCAM-IPHOC results will provide guidance to the other two models.
Structural design of off-axis aspheric surface reflective zoom optical system
NASA Astrophysics Data System (ADS)
Zhang, Ke; Chang, Jun; Song, Haiping; Niu, Yajun
2018-01-01
Designed an off-axis aspheric reflective zoom optical system, and produced a prototype. The system consists of three aspheric reflective lens, the zoom range is 30mm { 90mm. This system gave up the traditional structure of zoom cam, the lens moved using linear guide rail driven by motor, the positioning precision of which was 0.01mm. And introduced the design of support frames of each lens. The practice tests verified the rationality of the prototype structure design.
Pallaver, Carl B.; Morgan, Michael W.
1978-01-01
A cryogenic expansion engine includes intake and exhaust poppet valves each controlled by a cam having adjustable dwell, the valve seats for the valves being threaded inserts in the valve block. Each cam includes a cam base and a ring-shaped cam insert disposed at an exterior corner of the cam base, the cam base and cam insert being generally circular but including an enlarged cam dwell, the circumferential configuration of the cam base and cam dwell being identical, the cam insert being rotatable with respect to the cam base. GI CONTRACTUAL ORIGIN OF THE INVENTION The invention described herein was made in the course of, or under, a contract with the UNITED STATES ENERGY RESEARCH AND DEVELOPMENT ADMINISTRATION.
Edelhoff, Daniel; Beuer, Florian; Schweiger, Josef; Brix, Oliver; Stimmelmayr, Michael; Guth, Jan-Frederik
2012-06-01
Complex rehabilitations represent a particular challenge for the restorative team, especially if the vertical dimension of occlusion (VDO) needs to be reconstructed or redefined. The use of provisional acrylic or composite materials allows clinicians to evaluate the treatment objective over a certain period of time and therefore generates a high predictability of the definitive rehabilitation in terms of esthetics and function. CAD/CAM technology enables the use of prefabricated polymer materials, which are fabricated under industrial conditions to form a highly homogeneous structure compared with those of direct fabrication. This increases long-term stability, biocompatibility, and resistance to wear. Furthermore, they offer more suitable CAD/CAM processing characteristics and can be used in thinner thicknesses than ceramic restorative materials. Also, based on the improved long-term stability, the transfer into the definitive restoration can be divided into multiple treatment steps. This article presents different clinical cases with minimally invasive indications for CAD/CAM-fabricated temporary restorations for the pretreatment of complex cases.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, Sungsu
2014-12-12
The main goal of this project is to systematically quantify the major uncertainties of aerosol indirect effects due to the treatment of moist turbulent processes that drive aerosol activation, cloud macrophysics and microphysics in response to anthropogenic aerosol perturbations using the CAM5/CESM1. To achieve this goal, the P.I. hired a postdoctoral research scientist (Dr. Anna Fitch) who started her work from the Nov.1st.2012. In order to achieve the project goal, the first task that the Postdoc. and the P.I. did was to quantify the role of subgrid vertical velocity variance on the activation and nucleation of cloud liquid droplets andmore » ice crystals and its impact on the aerosol indirect effect in CAM5. First, we analyzed various LES cases (from dry stable to cloud-topped PBL) to check whether this isotropic turbulence assumption used in CAM5 is really valid. It turned out that this isotropic turbulence assumption is not universally valid. Consequently, from the analysis of LES, we derived an empirical formulation relaxing the isotropic turbulence assumption used for the CAM5 aerosol activation and ice nucleation, and implemented the empirical formulation into CAM5/CESM1, and tested in the single-column and global simulation modes, and examined how it changed aerosol indirect effects in the CAM5/CESM1. These results were reported in the poster section in the 18th Annual CESM workshop held in Breckenridge, CO during Jun.17-20.2013. While we derived an empirical formulation from the analysis of couple of LES from the first task, the general applicability of that empirical formulation was questionable, because it was obtained from the limited number of LES simulations. The second task we did was to derive a more fundamental analytical formulation relating vertical velocity variance to TKE using other information starting from basic physical principles. This was a somewhat challenging subject, but if this could be done in a successful way, it could be directly implemented into the CAM5 as a practical parameterization, and substantially contributes to achieving the project goal. Through an intensive research for about one year, we found appropriate mathematical formulation and tried to implement it into the CAM5 PBL and activation routine as a practical parameterized numerical code. During these processes, however, the Postdoc applied for another position in Sweden, Europe, and accepted a job offer there, and left NCAR in August 2014. In Sweden, Dr. Anna Fitch is still working on this subject in a part time, planning to finalize the research and to write the paper in a near future.« less
Broom, Alex; Tovey, Philip
2008-04-01
This article draws on a study of 80 National Health Service cancer patients and their experiences of using the Internet within disease and treatment processes. It focuses on the role the Internet plays in the context of potential or actual engagement with complementary and alternative medicine (CAM). The results depart from previous conceptualizations of the Internet as a major source of CAM knowledge, and second, as a major pathway to patient CAM usage. Moreover, the results highlight significant anxiety as patients attempt to process vast amounts of complex biomedical diagnostic and prognostic information online. For patients attempting to embrace alternative therapeutic models of cancer care, exposure to prognostic data may pose considerable risks to individual well-being and engagement with healing practices. On the basis of these results we problematize social theorizations of the Internet as contributing to such things as: the democratization of knowledge; the deprofessionalization of medicine; and patient empowerment. We emphasize, instead, the potential role of the Internet in reinforcing biomedicine's paradigmatic dominance in cancer care.
Oh, Ji-Hyeon
2018-12-01
With the development of computer-aided design/computer-aided manufacturing (CAD/CAM) technology, it has been possible to reconstruct the cranio-maxillofacial defect with more accurate preoperative planning, precise patient-specific implants (PSIs), and shorter operation times. The manufacturing processes include subtractive manufacturing and additive manufacturing and should be selected in consideration of the material type, available technology, post-processing, accuracy, lead time, properties, and surface quality. Materials such as titanium, polyethylene, polyetheretherketone (PEEK), hydroxyapatite (HA), poly-DL-lactic acid (PDLLA), polylactide-co-glycolide acid (PLGA), and calcium phosphate are used. Design methods for the reconstruction of cranio-maxillofacial defects include the use of a pre-operative model printed with pre-operative data, printing a cutting guide or template after virtual surgery, a model after virtual surgery printed with reconstructed data using a mirror image, and manufacturing PSIs by directly obtaining PSI data after reconstruction using a mirror image. By selecting the appropriate design method, manufacturing process, and implant material according to the case, it is possible to obtain a more accurate surgical procedure, reduced operation time, the prevention of various complications that can occur using the traditional method, and predictive results compared to the traditional method.
A comparison of two instructional methods for drawing Lewis Structures
NASA Astrophysics Data System (ADS)
Terhune, Kari
Two instructional methods for teaching Lewis structures were compared -- the Direct Octet Rule Method (DORM) and the Commonly Accepted Method (CAM). The DORM gives the number of bonds and the number of nonbonding electrons immediately, while the CAM involves moving electron pairs from nonbonding to bonding electrons, if necessary. The research question was as follows: Will high school chemistry students draw more accurate Lewis structures using the DORM or the CAM? Students in Regular Chemistry 1 (N = 23), Honors Chemistry 1 (N = 51) and Chemistry 2 (N = 15) at an urban high school were the study participants. An identical pretest and posttest was given before and after instruction. Students were given instruction with either the DORM (N = 45), the treatment method, or the CAM (N = 44), the control for two days. After the posttest, 15 students were interviewed, using a semistructured interview process. The pretest/posttest consisted of 23 numerical response questions and 2 to 6 free response questions that were graded using a rubric. A two-way ANOVA showed a significant interaction effect between the groups and the methods, F (1, 70) = 10.960, p = 0.001. Post hoc comparisons using the Bonferroni pairwise comparison showed that Reg Chem 1 students demonstrated larger gain scores when they had been taught the CAM (Mean difference = 3.275, SE = 1.324, p < 0.05), while Hon Chem 1 students demonstrated larger gain scores after learning the DORM (Mean difference = 1.931, SE = 0.848, p < 0.05). The DORM requires five mathematical operations, while the CAM only requires one. Honors Chemistry 1 students performed better with the DORM, perhaps due to better math skills, enhanced working memory, and better metacognitive skills. Regular Chemistry 1 students performed better with the CAM, perhaps because it is more visual. Teachers may want to use the CAM or a direct-pairing method to introduce the topic and use the DORM in advanced classes when a correct structure is needed quickly.
Kuźniak, Elżbieta; Kornas, Andrzej; Kaźmierczak, Andrzej; Rozpądek, Piotr; Nosek, Michał; Kocurek, Maciej; Zellnig, Günther; Müller, Maria; Miszalski, Zbigniew
2016-01-01
Background and Aims Leaf veins are usually encircled by specialized bundle sheath cells. In C4 plants, they play an important role in CO2 assimilation, and the photosynthetic activity is compartmentalized between the mesophyll and the bundle sheath. In C3 and CAM (Crassulacean acid metabolism) plants, the photosynthetic activity is generally attributed to the leaf mesophyll cells, and the vascular parenchymal cells are rarely considered for their role in photosynthesis. Recent studies demonstrate that enzymes required for C4 photosynthesis are also active in the veins of C3 plants, and their vascular system contains photosynthetically competent parenchyma cells. However, our understanding of photosynthesis in veins of C3 and CAM plants still remains insufficient. Here spatial analysis of photosynthesis-related properties were applied to the midrib and the interveinal lamina cells in leaves of Mesembryanthemum crystallinum, a C3–CAM intermediate plant. Methods The midrib anatomy as well as chloroplast structure and chlorophyll fluorescence, diurnal gas exchange profiles, the immunoblot patterns of PEPC (phosphoenolpyruvate carboxylase) and RubisCO (ribulose-1,5-bisphosphate carboxylase/oxygenase), H2O2 localization and antioxidant enzyme activities were compared in the midrib and in the interveinal mesophyll cells in leaves of C3 and CAM plants. Key Results Leaf midribs were structurally competent to perform photosynthesis in C3 and CAM plants. The midrib chloroplasts resembled those in the bundle sheath cells of C4 plants and were characterized by limited photosynthetic activity. Conclusions The metabolic roles of midrib chloroplasts differ in C3 and CAM plants. It is suggested that in leaves of C3 plants the midrib chloroplasts could be involved in the supply of CO2 for carboxylation, and in CAM plants they could provide malate to different metabolic processes and mediate H2O2 signalling. PMID:27091507
The Actin Nucleator Cobl Is Controlled by Calcium and Calmodulin
Haag, Natja; Kessels, Michael M.; Qualmann, Britta
2015-01-01
Actin nucleation triggers the formation of new actin filaments and has the power to shape cells but requires tight control in order to bring about proper morphologies. The regulation of the members of the novel class of WASP Homology 2 (WH2) domain-based actin nucleators, however, thus far has largely remained elusive. Our study reveals signal cascades and mechanisms regulating Cordon-Bleu (Cobl). Cobl plays some, albeit not fully understood, role in early arborization of neurons and nucleates actin by a mechanism that requires a combination of all three of its actin monomer–binding WH2 domains. Our experiments reveal that Cobl is regulated by Ca2+ and multiple, direct associations of the Ca2+ sensor Calmodulin (CaM). Overexpression analyses and rescue experiments of Cobl loss-of-function phenotypes with Cobl mutants in primary neurons and in tissue slices demonstrated the importance of CaM binding for Cobl’s functions. Cobl-induced dendritic branch initiation was preceded by Ca2+ signals and coincided with local F-actin and CaM accumulations. CaM inhibitor studies showed that Cobl-mediated branching is strictly dependent on CaM activity. Mechanistic studies revealed that Ca2+/CaM modulates Cobl’s actin binding properties and furthermore promotes Cobl’s previously identified interactions with the membrane-shaping F-BAR protein syndapin I, which accumulated with Cobl at nascent dendritic protrusion sites. The findings of our study demonstrate a direct regulation of an actin nucleator by Ca2+/CaM and reveal that the Ca2+/CaM-controlled molecular mechanisms we discovered are crucial for Cobl’s cellular functions. By unveiling the means of Cobl regulation and the mechanisms, by which Ca2+/CaM signals directly converge on a cellular effector promoting actin filament formation, our work furthermore sheds light on how local Ca2+ signals steer and power branch initiation during early arborization of nerve cells—a key process in neuronal network formation. PMID:26334624
Shraim, Naser Y; Shawahna, Ramzi; Sorady, Muna A; Aiesh, Banan M; Alashqar, Ghadeer Sh; Jitan, Raghad I; Abu Hanieh, Waed M; Hotari, Yasmeen B; Sweileh, Waleed M; Zyoud, Sa'ed H
2017-08-29
Complementary and alternative medicine (CAM) utilization is dramatically increasing among patients. As community pharmacies are a major provider of CAM products, community pharmacists need to have the sufficient knowledge and information to advice their patients, answer their inquiries and to be proactive in the healthcare process to ensure optimal therapy outputs and minimize both drug-drug and drug-herb interactions. Therefore, the main objective of this study was to assess the knowledge, beliefs, and practices of community pharmacists in Palestine about CAM. The study was conducted in a cross-sectional design in which a questionnaire was administered on a sample of licensed community pharmacists from Palestine. The questionnaire was of 5 sections: demographic and practice details of the participants, practice, beliefs, and knowledge about CAM. Mann-Whitney-U or Kruskal-Wallis tests were used to comparison of different issues as appropriate. P-values of <0.05 were considered significant. A total of 284 community pharmacists were surveyed, however, 281 were included in the analysis as they met inclusion criteria. Out of the 281, 149 (53.0%) of the participants were males and the rest were females. About 40% of the participants were between 20 to 29 years old. Pharmacists frequently recommended CAM modalities. Exercises (84.0%) and food supplements (82.6%) were the most commonly recommended modalities. In the last year, vitamin B 12 was the most frequently prescribed supplement. The median knowledge score was 5 out of 8 and the median beliefs about CAM score was 4.0 out of 7.0. CAM recommendations by pharmacists appear to be commonplace. Although their knowledge scores were fair to average, pharmacists still need more education and training about CAM in order to be more qualified to provide better pharmaceutical care and improve their patient's outcome.
Kuźniak, Elżbieta; Kornas, Andrzej; Kaźmierczak, Andrzej; Rozpądek, Piotr; Nosek, Michał; Kocurek, Maciej; Zellnig, Günther; Müller, Maria; Miszalski, Zbigniew
2016-06-01
Leaf veins are usually encircled by specialized bundle sheath cells. In C4 plants, they play an important role in CO2 assimilation, and the photosynthetic activity is compartmentalized between the mesophyll and the bundle sheath. In C3 and CAM (Crassulacean acid metabolism) plants, the photosynthetic activity is generally attributed to the leaf mesophyll cells, and the vascular parenchymal cells are rarely considered for their role in photosynthesis. Recent studies demonstrate that enzymes required for C4 photosynthesis are also active in the veins of C3 plants, and their vascular system contains photosynthetically competent parenchyma cells. However, our understanding of photosynthesis in veins of C3 and CAM plants still remains insufficient. Here spatial analysis of photosynthesis-related properties were applied to the midrib and the interveinal lamina cells in leaves of Mesembryanthemum crystallinum, a C3-CAM intermediate plant. The midrib anatomy as well as chloroplast structure and chlorophyll fluorescence, diurnal gas exchange profiles, the immunoblot patterns of PEPC (phosphoenolpyruvate carboxylase) and RubisCO (ribulose-1,5-bisphosphate carboxylase/oxygenase), H2O2 localization and antioxidant enzyme activities were compared in the midrib and in the interveinal mesophyll cells in leaves of C3 and CAM plants. Leaf midribs were structurally competent to perform photosynthesis in C3 and CAM plants. The midrib chloroplasts resembled those in the bundle sheath cells of C4 plants and were characterized by limited photosynthetic activity. The metabolic roles of midrib chloroplasts differ in C3 and CAM plants. It is suggested that in leaves of C3 plants the midrib chloroplasts could be involved in the supply of CO2 for carboxylation, and in CAM plants they could provide malate to different metabolic processes and mediate H2O2 signalling. © The Author 2016. Published by Oxford University Press on behalf of the Annals of Botany Company. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
CERT Resilience Management Model Capability Appraisal Method (CAM) Version 1.1
2011-10-01
the CERT-RMM CAM V1.1 method is that satisfaction of goals can be determined only upon detailed investigation of the extent to which each...achievement of a specific maturity level or the satisfaction of a process area must mean the same thing for different appraised organizations. The...rate the satisfaction of the goals, based on the extent of practice implementation, for the appraisal reference model and organizational scope
[Alternative and complementary therapies in fibromyalgia syndrome].
Langhorst, J; Häuser, W; Irnich, D; Speeck, N; Felde, E; Winkelmann, A; Lucius, H; Michalsen, A; Musial, F
2008-06-01
Interdisciplinary S3 level guidelines were devised in cooperation with 8 medical, 2 psychological and 2 patient support groups. Results were elaborated in a multilevel group process. On the bases of the "Cochrane Library" (1993-2006), "Medline" (1980-2006), "PsychInfo" (2006) and "Scopus" (2006) controlled studies and meta-analyses of controlled studies were analyzed. Only few controlled studies were found supporting in part the effectiveness of CAM therapies in the treatment of fibromyalgia syndrome. Due to the lack of information on long term efficacy and cost-effectiveness, only limited recommendations for CAM therapies can be given. Within a multicomponent therapy setting, selective CAM therapies (acupuncture, vegetarian diet, homeopathy, Tai Chi, Qi Gong, music-oriented and body-oriented therapies) can be recommended for a limited period of time.
NASA Astrophysics Data System (ADS)
Richardson, A. D.
2015-12-01
Vegetation phenology controls the seasonality of many ecosystem processes, as well as numerous biosphere-atmosphere feedbacks. Phenology is highly sensitive to climate change and variability, and is thus a key aspect of global change ecology. The goal of the PhenoCam network is to serve as a long-term, continental-scale, phenological observatory. The network uses repeat digital photography—images captured using conventional, visible-wavelength, automated digital cameras—to characterize vegetation phenology in diverse ecosystems across North America and around the world. At present, imagery from over 200 research sites, spanning a wide range of ecoregions, climate zones, and plant functional types, is currently being archived and processed in near-real-time through the PhenoCam project web page (http://phenocam.sr.unh.edu/). Data derived from PhenoCam imagery have been previously used to evaluate satellite phenology products, to constrain and test new phenology models, to understand relationships between canopy phenology and ecosystem processes, and to study the seasonal changes in leaf-level physiology that are associated with changes in leaf color. I will describe a new, publicly-available phenological dataset, derived from over 600 site-years of PhenoCam imagery. For each archived image (ca. 5 million), we extracted RGB (red, green, blue) color channel information, with means and other statistics calculated across a region-of-interest (ROI) delineating a specific vegetation type. From the high-frequency (typically, 30 minute) imagery, we derived time series characterizing vegetation color, including "canopy greenness", processed to 1- and 3-day intervals. For ecosystems with a single annual cycle of vegetation activity, we derived estimates, with uncertainties, for the start, middle, and end of spring and autumn phenological transitions. Given the lack of multi-year, standardized, and geographically distributed phenological data for North America, we anticipate that these datasets will be widely used by researchers in a variety of fields. Shifts in phenology are a particularly tangible example of the biological impacts of climate change, and thus these data may also find use in science education and outreach to the general public.
Yoshida, Kazuya
2018-01-01
To evaluate the effectiveness and safety of botulinum toxin administration into the inferior head of the lateral pterygoid muscle of patients with jaw opening dystonia by using a computer-aided design/computer-assisted manufacture (CAD/CAM)-derived needle guide. A total of 17 patients with jaw opening dystonia were enrolled. After the patient's computed tomography (CT) scan was imported and fused with a scan of a plaster cast model of the maxilla, the optimal needle insertion site over the lateral pterygoid muscle was determined using the NobelClinician software. A total of 13 patients were injected both with and without the guide, and 4 patients underwent guided injection alone. The therapeutic effects of botulinum toxin injection and its associated complications were statistically compared between the guided and unguided procedures using paired t test. Botulinum toxin therapy was performed 42 and 32 times with and without the guides, respectively. The needle was easily inserted without any complications in all procedures. There was a significant difference (P < .001) between the mean comprehensive improvements observed with (66.3%) and without (54.4%) the guides. The findings suggest that the use of needle guides during the injection of botulinum toxin into the inferior head of the lateral pterygoid muscle is very useful for aiding the accurate and safe administration of botulinum toxin therapy for jaw opening dystonia.
Abiotic stress responses in plants: roles of calmodulin-regulated proteins.
Virdi, Amardeep S; Singh, Supreet; Singh, Prabhjeet
2015-01-01
Intracellular changes in calcium ions (Ca(2+)) in response to different biotic and abiotic stimuli are detected by various sensor proteins in the plant cell. Calmodulin (CaM) is one of the most extensively studied Ca(2+)-sensing proteins and has been shown to be involved in transduction of Ca(2+) signals. After interacting with Ca(2+), CaM undergoes conformational change and influences the activities of a diverse range of CaM-binding proteins. A number of CaM-binding proteins have also been implicated in stress responses in plants, highlighting the central role played by CaM in adaptation to adverse environmental conditions. Stress adaptation in plants is a highly complex and multigenic response. Identification and characterization of CaM-modulated proteins in relation to different abiotic stresses could, therefore, prove to be essential for a deeper understanding of the molecular mechanisms involved in abiotic stress tolerance in plants. Various studies have revealed involvement of CaM in regulation of metal ions uptake, generation of reactive oxygen species and modulation of transcription factors such as CAMTA3, GTL1, and WRKY39. Activities of several kinases and phosphatases have also been shown to be modulated by CaM, thus providing further versatility to stress-associated signal transduction pathways. The results obtained from contemporary studies are consistent with the proposed role of CaM as an integrator of different stress signaling pathways, which allows plants to maintain homeostasis between different cellular processes. In this review, we have attempted to present the current state of understanding of the role of CaM in modulating different stress-regulated proteins and its implications in augmenting abiotic stress tolerance in plants.
Abiotic stress responses in plants: roles of calmodulin-regulated proteins
Virdi, Amardeep S.; Singh, Supreet; Singh, Prabhjeet
2015-01-01
Intracellular changes in calcium ions (Ca2+) in response to different biotic and abiotic stimuli are detected by various sensor proteins in the plant cell. Calmodulin (CaM) is one of the most extensively studied Ca2+-sensing proteins and has been shown to be involved in transduction of Ca2+ signals. After interacting with Ca2+, CaM undergoes conformational change and influences the activities of a diverse range of CaM-binding proteins. A number of CaM-binding proteins have also been implicated in stress responses in plants, highlighting the central role played by CaM in adaptation to adverse environmental conditions. Stress adaptation in plants is a highly complex and multigenic response. Identification and characterization of CaM-modulated proteins in relation to different abiotic stresses could, therefore, prove to be essential for a deeper understanding of the molecular mechanisms involved in abiotic stress tolerance in plants. Various studies have revealed involvement of CaM in regulation of metal ions uptake, generation of reactive oxygen species and modulation of transcription factors such as CAMTA3, GTL1, and WRKY39. Activities of several kinases and phosphatases have also been shown to be modulated by CaM, thus providing further versatility to stress-associated signal transduction pathways. The results obtained from contemporary studies are consistent with the proposed role of CaM as an integrator of different stress signaling pathways, which allows plants to maintain homeostasis between different cellular processes. In this review, we have attempted to present the current state of understanding of the role of CaM in modulating different stress-regulated proteins and its implications in augmenting abiotic stress tolerance in plants. PMID:26528296
Hammerle, Albin; Meier, Fred; Heinl, Michael; Egger, Angelika; Leitinger, Georg
2017-04-01
Thermal infrared (TIR) cameras perfectly bridge the gap between (i) on-site measurements of land surface temperature (LST) providing high temporal resolution at the cost of low spatial coverage and (ii) remotely sensed data from satellites that provide high spatial coverage at relatively low spatio-temporal resolution. While LST data from satellite (LST sat ) and airborne platforms are routinely corrected for atmospheric effects, such corrections are barely applied for LST from ground-based TIR imagery (using TIR cameras; LST cam ). We show the consequences of neglecting atmospheric effects on LST cam of different vegetated surfaces at landscape scale. We compare LST measured from different platforms, focusing on the comparison of LST data from on-site radiometry (LST osr ) and LST cam using a commercially available TIR camera in the region of Bozen/Bolzano (Italy). Given a digital elevation model and measured vertical air temperature profiles, we developed a multiple linear regression model to correct LST cam data for atmospheric influences. We could show the distinct effect of atmospheric conditions and related radiative processes along the measurement path on LST cam , proving the necessity to correct LST cam data on landscape scale, despite their relatively low measurement distances compared to remotely sensed data. Corrected LST cam data revealed the dampening effect of the atmosphere, especially at high temperature differences between the atmosphere and the vegetated surface. Not correcting for these effects leads to erroneous LST estimates, in particular to an underestimation of the heterogeneity in LST, both in time and space. In the most pronounced case, we found a temperature range extension of almost 10 K.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zheng, Xue; Klein, S. A.; Ma, H. -Y.
To assess marine boundary layer (MBL) cloud simulations in three versions of the Community Atmosphere Model (CAM), three sets of short-term global hindcasts are performed and compared to Atmospheric Radiation Measurement Program (ARM) observations on Graciosa Island in the Azores from June 2009 to December 2010. Here, the three versions consist of CAM5.3 with default schemes (CAM5.3), CAM5.3 with Cloud Layers Unified By Binormals (CLUBB-MG1), and CAM5.3 with CLUBB and updated microphysics scheme (CLUBB-MG2). Our results show that relative to CAM5.3 default schemes, simulations with CLUBB better represent MBL cloud base height, the height of the major cloud layer, andmore » the daily cloud cover variability. CLUBB also better simulates the relationship of cloud fraction to cloud liquid water path (LWP) most likely due to CLUBB's consistent treatment of these variables through a probability distribution function (PDF) approach. Subcloud evaporation of precipitation is substantially enhanced in simulations with CLUBB-MG2 and is more realistic based on the limited observational estimate. Despite these improvements, all model versions underestimate MBL cloud cover. CLUBB-MG2 reduces biases in in-cloud LWP (clouds are not too bright) but there are still too few of MBL clouds due to an underestimate in the frequency of overcast scenes. Thus, combining CLUBB with MG2 scheme better simulates MBL cloud processes, but because biases remain in MBL cloud cover CLUBB-MG2 does not improve the simulation of the surface shortwave cloud radiative effect (CRE SW).« less
Zheng, Xue; Klein, S. A.; Ma, H. -Y.; ...
2016-07-19
To assess marine boundary layer (MBL) cloud simulations in three versions of the Community Atmosphere Model (CAM), three sets of short-term global hindcasts are performed and compared to Atmospheric Radiation Measurement Program (ARM) observations on Graciosa Island in the Azores from June 2009 to December 2010. Here, the three versions consist of CAM5.3 with default schemes (CAM5.3), CAM5.3 with Cloud Layers Unified By Binormals (CLUBB-MG1), and CAM5.3 with CLUBB and updated microphysics scheme (CLUBB-MG2). Our results show that relative to CAM5.3 default schemes, simulations with CLUBB better represent MBL cloud base height, the height of the major cloud layer, andmore » the daily cloud cover variability. CLUBB also better simulates the relationship of cloud fraction to cloud liquid water path (LWP) most likely due to CLUBB's consistent treatment of these variables through a probability distribution function (PDF) approach. Subcloud evaporation of precipitation is substantially enhanced in simulations with CLUBB-MG2 and is more realistic based on the limited observational estimate. Despite these improvements, all model versions underestimate MBL cloud cover. CLUBB-MG2 reduces biases in in-cloud LWP (clouds are not too bright) but there are still too few of MBL clouds due to an underestimate in the frequency of overcast scenes. Thus, combining CLUBB with MG2 scheme better simulates MBL cloud processes, but because biases remain in MBL cloud cover CLUBB-MG2 does not improve the simulation of the surface shortwave cloud radiative effect (CRE SW).« less
Nichol, James; Thompson, Elizabeth A; Shaw, Alison
2011-02-01
The rise in complementary and alternative medicine (CAM) use is well documented. Surveys provide varying estimates of the prevalence of CAM use. Qualitative research has explored individuals' decision-making regarding CAM. This study aimed to examine the family as a context for beliefs, decision-making, and dialogue about CAM. Families were recruited via the Avon Longitudinal Study of Parents and Children. A subsample of CAM users was targeted using purposeful sampling. Focus groups and interviews were conducted with 15 families and the data were analyzed thematically. Family understandings and beliefs about CAM: CAM was understood as treatments provided outside mainstream care, offering a more "natural" and "holistic" approach, tailored to individual needs and overlapping with wider healthy lifestyle practices. Hierarchies of acceptability of CAM: Physical and "mainstream" therapies were widely supported, with "fringe" therapies producing the most polarized views. There was a belief particularly among fathers and young people that certain therapies rely on "placebo" effects and their value was contested. Types of CAM users within families: Family members were predominantly "pragmatic" CAM users, with "committed" users (all mothers) characterized by deeper philosophical commitment to CAM and skepticism toward conventional medicine. Family dynamics of CAM decision-making: Mothers tended to "champion" CAM within families, while not determining family CAM use. Fathers largely positioned themselves as lacking expertise or skeptical of CAM. Young people were beginning to articulate independent and more critical views of CAM, some directly challenging their mother's perspective. However, all families shared openness to CAM as part of broader beliefs in proactive healthy lifestyles. Family focus groups and interviews allow a window on beliefs, decision-making, and dialogue about CAM within families, illuminating the CAM "champion" role held by mothers, and young people's developing autonomy regarding health beliefs and decision-making.
Büchi, Dominik L; Ebler, Sabine; Hämmerle, Christoph H F; Sailer, Irena
2014-01-01
To test whether or not different types of CAD/CAM systems, processing zirconia in the densely and in the pre-sintered stage, lead to differences in the accuracy of 4-unit anterior fixed dental prosthesis (FDP) frameworks, and to evaluate the efficiency. 40 curved anterior 4-unit FDP frameworks were manufactured with four different CAD/CAM systems: DCS Precident (DCS) (control group), Cercon (DeguDent) (test group 1), Cerec InLab (Sirona) (test group 2), Kavo Everest (Kavo) (test group 3). The DCS System was chosen as the control group because the zirconia frameworks are processed in its densely sintered stage and there is no shrinkage of the zirconia during the manufacturing process. The initial fit of the frameworks was checked and adjusted to a subjectively similar level of accuracy by one dental technician, and the time taken for this was recorded. After cementation, the frameworks were embedded into resin and the abutment teeth were cut in mesiodistal and orobuccal directions in four specimens. The thickness of the cement gap was measured at 50× (internal adaptation) and 200× (marginal adaptation) magnification. The measurement of the accuracy was performed at four sites. Site 1: marginal adaptation, the marginal opening at the point of closest perpendicular approximation between the die and framework margin. Site 2: Internal adaptation at the chamfer. Site 3: Internal adaptation at the axial wall. Site 4: Internal adaptation in the occlusal area. The data were analyzed descriptively using the ANOVA and Bonferroni/ Dunn tests. The mean marginal adaptation (site 1) of the control group was 107 ± 26 μm; test group 1, 140 ± 26 μm; test group 2, 104 ± 40 μm; and test group 3, 95 ± 31 μm. Test group 1 showed a tendency to exhibit larger marginal gaps than the other groups, however, this difference was only significant when test groups 1 and 3 were compared (P = .0022; Bonferroni/Dunn test). Significantly more time was needed for the adjustment of the frameworks of test group 1 compared to the other test groups and the control group (21.1 min vs 3.8 min) (P < .0001; Bonferroni/Dunn test). For the adjustment of the frameworks of test groups 2 and 3, the same time was needed as for the frameworks of the control group. No differences of the framework accuracy resulting from the different CAM and CAD/CAM procedures were found; however, only after adjustment of the fit by an experienced dental technician. Hence, the influence of a manual correction of the fit was crucial, and the efforts differed for the tested systems. The CAM system led to lower initial accuracy of the frameworks than the CAD/CAM systems, which may be crucial for the dental laboratory. The stage of the zirconia materials used for the different CAD/CAM procedures, ie presintered or densely sintered, exhibited no influence.
Digital Denture Fabrication in Pre- and Postdoctoral Education: A Survey of U.S. Dental Schools.
Fernandez, Monica A; Nimmo, Arthur; Behar-Horenstein, Linda S
2016-01-01
To survey chairs of prosthodontics or restorative departments and program directors of postdoctoral prosthodontic programs in the United States regarding digital denture fabrication. The key objectives of the survey were to identify the current trends in complete denture fabrication using CAD/CAM technology and to determine how and to what extent this technique is taught and used in U.S. pre- and postdoctoral prosthodontic programs. An invitation to participate in an online survey was sent to 52 prosthodontics/restorative chairs of U.S. dental schools and to all of the 50 program directors of postdoctoral prosthodontics programs. A version of the survey with the same questions was sent to a national sample of prosthodontics/restorative chairs and program directors of postdoctoral prosthodontics. The 20-item survey took approximately 15 minutes to complete. Dependent samples paired t-test was run on items that were the same in both surveys. The response rate for the survey was 63% for department chairs and 44% for program directors. All respondents with the exception of one department chair were aware of CAD/CAM technology used for denture fabrication. More than half of the program directors (52.4%) compared to 12.1% of chairs have incorporated some aspects of CAD/CAM denture fabrication technology into their curriculum. When asked if the fabrication cost prevented introducing this technology in the predoctoral/postdoctoral curriculum, 52.4% of the department chairs affirmed this response compared to 12.1% of the program directors. There was a significant difference between groups when asked if they had incorporated the CAD/CAM denture fabrication technique into the postgraduate/predoctoral curriculum. Department chairs reported less usage of CAD/CAM technology. Only 12.1% of department chairs reported using some aspects of CAD/CAM technology in the predoctoral curriculum compared to 52.4% in the postdoctoral curriculum (F = 13.528, p ≤ 0.001). While this technology is used in four predoctoral clinics, none of the chairs reported including CAD/CAM denture fabrication in their preclinical complete denture courses. For the schools using the technology, 33.3% of postdoctoral and 30.3% of predoctoral programs use it to make a denture with a try-in step; however, 19% of the postdoctoral and 18.2% of predoctoral programs process the dentures without a try-in appointment. Slightly less than half (42.9%) of graduate programs are using the technology to make just the denture bases. Only a small proportion (10% or less) of the total number of dentures processed in post- and predoctoral programs are made using CAD/CAM technology. The proportion of postdoctoral programs that process cases using CAD/CAM technology was significantly higher than in predoctoral programs (F = 5.106, p ≤ 0.028). Many schools indicated that they are in a "trial phase" to evaluate the technique, especially at the predoctoral level. Also, 19% (n = 4) of postdoctoral and 15.2% (n = 5) of predoctoral respondents have created continuing education courses. Of postdoctoral programs, 38.1% (n = 8) plan to introduce this technology at some point in the near future (next 1 to 4 years); 27.3% of predoctoral programs plan to as well. All program directors and department chairs who participated in the survey are aware of this technology with the exception of one department chair. More than half of the program directors reported that they have incorporated this technology in their curricula compared to only 12% of department chairs. Currently, only 10% or less of complete denture cases are processed using the CAD/CAM technology, at either the post- or predoctoral levels. Both groups reported that the main use of this technology is for the fabrication of denture bases and for processing dentures including the try-in step. The majority of respondents in both groups indicated they plan to add digital denture fabrication into their curricula within the next 1 to 4 years. © 2015 by the American College of Prosthodontists.
Shorofi, Seyed Afshin
2011-11-01
This paper reports a study to examine hospitalised patients' frequency and patterns of CAM use, their reasons for CAM use, their preferences of CAMs during hospitalisation, and the association between patients' socio-demographic variables and use of each individual CAM/CAM domain. A convenience sample of 353 patients hospitalised in 19 surgical wards at four metropolitan hospitals completed a questionnaire on CAM use and socio-demographic variables. The response rate was 73.5%, and over 90% of the sample acknowledged using CAMs. Non-herbal supplements (60.3%) and massage therapy (45%) were the most frequently used CAMs, with biologically based therapies (68.8%) as well as mind-body interventions (65.4%) being the most often used CAM domains. About 1 in 10 patients (9.6%) used CAMs from all five domains. With the exception of herbal-botanical therapies, self-prayer for health reasons/spiritual healing and music therapy, all CAMs were mainly used on an 'only when needed' basis. The most common reason nominated for using CAMs was that '[it] fits into my way of life/philosophy' (26%). The majority of patients declared interest in and support for the hospital providing CAMs. Patients were most inclined to choose therapies categorised as manipulative and body-based methods (65.4%) for use in hospital. Massage therapy (53.5%) and non-herbal supplements (43.1%) were the top two CAMs favoured for use in hospital. CAM use was also dependent of socio-demographic data (age, gender, marital status, place of residence, education level, religion, and income in hospitalised patients). The use of CAMs is pervasive amongst surgical in-patients, making it feasible to initially assess these patients for CAM use and provide them with clinically approved CAMs where possible. Notwithstanding that CAM use is fairly predictable by socio-demographic variables, further studies should be directed to know the variables useful for predicting the use of each CAM approach. Copyright © 2011 Elsevier Ltd. All rights reserved.
Yang, Geliang; Zhang, Huiqing; Gan, Zheng; Fan, Yifu; Gu, Wei; Ling, Changquan
2018-06-01
Complementary and alternative medicine (CAM) has been widely used by cancer patients but rarely discussed by oncologists. This study was designed to evaluate the communication gap between China's oncologists and cancer patients on CAM. Two parallel cross-sectional studies assessed 83 oncologists and 402 cancer patients on CAM communication between patients and oncologists, and attitudes toward CAM use and clinical decisions about CAM. A majority (75.1%) of the cancer patients (302/402) were identified as CAM users within the most recent three months while 77.6% of the cancer patients (312/402) were identified as CAM users since diagnosis of cancer. Oncologists and patients responded differently ( P < .001) on CAM communications. Both oncologists and patients expected that CAM could improve the immune system. They both agreed that oncologists usually discouraged their patients from using CAM. Regarding the effectiveness of CAM, cancer patients were more likely to believe that CAM was effective while oncologists had more concerns about adverse effects of CAM use. CAM use by patients was predicted by disease duration (≥9 months) in the multivariable logistic regression model. China's oncologists and cancer patients may hold discrepant views on CAM. China's oncologists are encouraged to improve their knowledge on CAM and to initiate more discussions with their patients regarding effective and the safe use of CAM.
St Jacques, Peggy L; Conway, Martin A; Cabeza, Roberto
2011-10-01
Gender differences are frequently observed in autobiographical memory (AM). However, few studies have investigated the neural basis of potential gender differences in AM. In the present functional MRI (fMRI) study we investigated gender differences in AMs elicited using dynamic visual images vs verbal cues. We used a novel technology called a SenseCam, a wearable device that automatically takes thousands of photographs. SenseCam differs considerably from other prospective methods of generating retrieval cues because it does not disrupt the ongoing experience. This allowed us to control for potential gender differences in emotional processing and elaborative rehearsal, while manipulating how the AMs were elicited. We predicted that males would retrieve more richly experienced AMs elicited by the SenseCam images vs the verbal cues, whereas females would show equal sensitivity to both cues. The behavioural results indicated that there were no gender differences in subjective ratings of reliving, importance, vividness, emotion, and uniqueness, suggesting that gender differences in brain activity were not due to differences in these measures of phenomenological experience. Consistent with our predictions, the fMRI results revealed that males showed a greater difference in functional activity associated with the rich experience of SenseCam vs verbal cues, than did females.
Braun, M Miles
2013-10-01
Study of complementary and alternative medicine's mind and body interventions (CAM-MABI) is hindered not only by the inability to mask participants and their teachers to the study intervention but also by the major practical hurdles of long-term study of practices that can be lifelong. Two other important methodological problems are that study of newly trained practitioners cannot directly address long-term practice, and that long-term practitioners likely self-select in ways that make finding appropriate controls (or a comparison group) challenging. The temporary practice pause then resumption study design (TPPR) introduced here is a new tool that extends the withdrawal study design, established in the field of drug evaluation, to the field of CAM-MABI. With the exception of the inability to mask, TPPR can address the other methodological problems noted above. Of great interest to investigators will likely be measures in practitioners of CAM-MABI that change with temporary pausing of CAM-MABI practice, followed by return of the measures to pre-pause levels with resumption of practice; this would suggest a link of the practice to measured changes. Such findings using this tool may enhance our insight into fundamental biological processes, leading to beneficial practical applications.
Zimmermann, Moritz; Koller, Christina; Mehl, Albert; Hickel, Reinhard
2017-01-01
No clinical data are available for the new computer-aided design/computer-assisted manufacture (CAD/CAM) material zirconia-reinforced lithium silicate (ZLS) ceramic. This study describes preliminary clinical results for indirect ZLS CAD/CAM restorations after 12 months. Indirect restorations were fabricated, using the CEREC method and intraoral scanning (CEREC Omnicam, CEREC MCXL). Sixty-seven restorations were seated adhesively (baseline). Sixty restorations were evaluated after 12 months (follow-up), using modified FDI criteria. Two groups were established, according to ZLS restorations' post-processing procedure prior to adhesive seating: group I (three-step polishing, n = 32) and group II (fire glazing, n = 28). Statistical analysis was performed with Mann-Whitney U test and Wilcoxon test (P < .05). The success rate of indirect ZLS CAD/CAM restorations after 12 months was 96.7%. Two restorations clinically failed as a result of bulk fracture (failure rate 3.3%). No statistically significant differences were found for baseline and follow-up criteria (Wilcoxon test, P > .05). Statistically significant differences were found for criteria surface gloss for group I and group II (Mann-Whitney U test, P < .05). This study demonstrates ZLS CAD/CAM restorations have a high clinical success rate after 12 months. A longer clinical evaluation period is necessary to draw further conclusions.
EGFR-Based Immunoisolation as a Recovery Target for Low-EpCAM CTC Subpopulation
Vila, Ana; Abal, Miguel; Muinelo-Romay, Laura; Rodriguez-Abreu, Carlos; Rivas, José; López-López, Rafael; Costa, Clotilde
2016-01-01
Circulating tumour cells (CTCs) play a key role in the metastasis process, as they are responsible for micrometastasis and are a valuable tool for monitoring patients in real-time. Moreover, efforts to develop new strategies for CTCs isolation and characterisation, and the translation of CTCs into clinical practice needs to overcome the limitation associated with the sole use of Epithelial Cell Adhesion Molecule (EpCAM) expression to purify this tumour cell subpopulation. CTCs are rare events in the blood of patients and are believed to represent the epithelial population from a primary tumour of epithelial origin, thus EpCAM immunoisolation is considered an appropriate strategy. The controversy stems from the impact that the more aggressive mesenchymal tumour phenotypes might have on the whole CTC population. In this work, we first characterised a panel of cell lines representative of tumour heterogeneity, confirming the existence of tumour cell subpopulations with restricted epithelial features and supporting the limitations of EpCAM-based technologies. We next developed customised polystyrene magnetic beads coated with antibodies to efficiently isolate the phenotypically different subpopulations of CTCs from the peripheral blood mononuclear cells (PBMCs) of patients with metastatic cancer. Besides EpCAM, we propose Epidermal Growth Factor Receptor (EGFR) as an additional isolation marker for efficient CTCs detection. PMID:27711186
Kubota, So; Inaba, Yutaka; Kobayashi, Naomi; Choe, Hyonmin; Tezuka, Taro; Saito, Tomoyuki
2017-10-16
While cam resection is essential to achieve a good clinical result with respect to femoroacetabular impingement (FAI), it is unclear whether it should also be performed in cases of borderline developmental dysplasia of the hip (DDH) with a cam deformity. The aim of this study was to evaluate improvements in range of motion (ROM) in cases of cam-type FAI and borderline DDH after virtual osteochondroplasty using a computer impingement simulation. Thirty-eight symptomatic hips in 31 patients (11male and 20 female) diagnosed with cam-type FAI or borderline DDH were analyzed. There were divided into a cam-type FAI group (cam-FAI group: 15 hips), borderline DDH without cam group (DDH W/O cam group: 12 hips), and borderline DDH with cam group (DDH W/ cam group: 11 hips). The bony impingement point on the femoral head-neck junction at 90° flexion and maximum internal rotation of the hip joint was identified using ZedHip® software. Virtual osteochondroplasty of the impingement point was then performed in all cases. The maximum flexion angle and maximum internal rotation angle at 90° flexion were measured before and after virtual osteochondroplasty at two resection ranges (i.e., slight and sufficient). The mean improvement in the internal rotation angle in the DDH W/ cam group after slight resection was significantly greater than that in the DDH W/O cam group (P = 0.046). Furthermore, the mean improvement in the internal rotation angle in the DDH W/ cam and cam-FAI groups after sufficient resection was significantly greater than that in the DDH W/O cam group (DDH W/ cam vs DDH W/O cam: P = 0.002, cam-FAI vs DDH W/O cam: P = 0.043). Virtual osteochondroplasty resulted in a significant improvement in internal rotation angle in DDH W/ cam group but not in DDH W/O cam group. Thus, borderline DDH cases with cam deformity may be better to consider performing osteochondroplasty.
Kinematic analysis of crank -cam mechanism of process equipment
NASA Astrophysics Data System (ADS)
Podgornyj, Yu I.; Skeeba, V. Yu; Martynova, T. G.; Pechorkina, N. S.; Skeeba, P. Yu
2018-03-01
This article discusses how to define the kinematic parameters of a crank-cam mechanism. Using the mechanism design, the authors have developed a calculation model and a calculation algorithm that allowed the definition of kinematic parameters of the mechanism, including crank displacements, angular velocities and acceleration, as well as driven link (rocker arm) angular speeds and acceleration. All calculations were performed using the Mathcad mathematical package. The results of the calculations are reported as numerical values.
Parallel Wavefront Analysis for a 4D Interferometer
NASA Technical Reports Server (NTRS)
Rao, Shanti R.
2011-01-01
This software provides a programming interface for automating data collection with a PhaseCam interferometer from 4D Technology, and distributing the image-processing algorithm across a cluster of general-purpose computers. Multiple instances of 4Sight (4D Technology s proprietary software) run on a networked cluster of computers. Each connects to a single server (the controller) and waits for instructions. The controller directs the interferometer to several images, then assigns each image to a different computer for processing. When the image processing is finished, the server directs one of the computers to collate and combine the processed images, saving the resulting measurement in a file on a disk. The available software captures approximately 100 images and analyzes them immediately. This software separates the capture and analysis processes, so that analysis can be done at a different time and faster by running the algorithm in parallel across several processors. The PhaseCam family of interferometers can measure an optical system in milliseconds, but it takes many seconds to process the data so that it is usable. In characterizing an adaptive optics system, like the next generation of astronomical observatories, thousands of measurements are required, and the processing time quickly becomes excessive. A programming interface distributes data processing for a PhaseCam interferometer across a Windows computing cluster. A scriptable controller program coordinates data acquisition from the interferometer, storage on networked hard disks, and parallel processing. Idle time of the interferometer is minimized. This architecture is implemented in Python and JavaScript, and may be altered to fit a customer s needs.
Cognitive interviews guide design of a new CAM patient expectations questionnaire.
Sherman, Karen J; Eaves, Emery R; Ritenbaugh, Cheryl; Hsu, Clarissa; Cherkin, Daniel C; Turner, Judith A
2014-01-25
No consistent relationship exists between pre-treatment expectations and therapeutic benefit from various complementary and alternative medicine (CAM) therapies in clinical trials. However, many different expectancy measures have been used in those studies, with no validated questionnaires clearly focused on CAM and pain. We undertook cognitive interviews as part of a process to develop and validate such a questionnaire. We reviewed questions about expectations of benefits of acupuncture, chiropractic, massage, or yoga for pain. Components of the questions - verbs, nouns, response options, terms and phrases describing back pain - were identified. Using seven different cognitive interview scripts, we conducted 39 interviews to evaluate how individuals with chronic low back pain understood these individual components in the context of expectancy questions for a therapy they had not yet received. Chosen items were those with the greatest agreement and least confusion among participants, and were closest to the meanings intended by the investigators. The questionnaire drafted for psychometric evaluation had 18 items covering various domains of expectancy. "Back pain" was the most consistently interpreted descriptor for this condition. The most understandable response options were 0-10 scales, a structure used throughout the questionnaire, with 0 always indicating no change, and 10 anchored with an absolute descriptor such as "complete relief". The use of words to describe midpoints was found to be confusing. The word "expect" held different and shifting meanings for participants. Thus paired items comparing "hope" and "realistically expect" were chosen to evaluate 5 different aspects of treatment expectations (back pain; back dysfunction and global effects; impact of back pain on specific areas of life; sleep, mood, and energy; coping). "Impact of back pain" on various areas of life was found to be a consistently meaningful concept, and more global than "interference". Cognitive interviews identified wordings with considerable agreement among both participants and investigators. Some items widely used in clinical studies had different meanings to participants than investigators, or were confusing to participants. The final 18-item questionnaire is undergoing psychometric evaluation with goals of streamlining as well as identifying best items for use when questionnaire length is constrained.
Kristoffersen, Agnete Egilsdatter; Fønnebø, Vinjar; Norheim, Arne Johan
2008-10-01
Self-reported use of complementary and alternative medicine (CAM) among patients varies widely between studies, possibly because the definition of a CAM user is not comparable. This makes it difficult to compare studies. The aim of this study is to present a six-level model for classifying patients' reported exposure to CAM. Prayer, physical exercise, special diets, over-the-counter products/CAM techniques, and personal visits to a CAM practitioner are successively removed from the model in a reductive fashion. By applying the model to responses given by Norwegian patients with cancer, we found that 72% use CAM if the user was defined to include all types of CAM. This proportion was reduced successively to only 11% in the same patient group when a CAM user was defined as a user visiting a CAM practitioner four or more times. When considering a sample of 10 recently published studies of CAM use among patients with breast cancer, we found 98% use when the CAM user was defined to include all sorts of CAM. This proportion was reduced successively to only 20% when a CAM user was defined as a user of a CAM practitioner. We recommend future surveys of CAM use to report at more than one level and to clarify which intensity level of CAM use the report is based on.
Winter, Klaus; Holtum, Joseph A M
2014-07-01
Facultative crassulacean acid metabolism (CAM) describes the optional use of CAM photosynthesis, typically under conditions of drought stress, in plants that otherwise employ C3 or C4 photosynthesis. In its cleanest form, the upregulation of CAM is fully reversible upon removal of stress. Reversibility distinguishes facultative CAM from ontogenetically programmed unidirectional C3-to-CAM shifts inherent in constitutive CAM plants. Using mainly measurements of 24h CO2 exchange, defining features of facultative CAM are highlighted in five terrestrial species, Clusia pratensis, Calandrinia polyandra, Mesembryanthemum crystallinum, Portulaca oleracea and Talinum triangulare. For these, we provide detailed chronologies of the shifts between photosynthetic modes and comment on their usefulness as experimental systems. Photosynthetic flexibility is also reviewed in an aquatic CAM plant, Isoetes howellii. Through comparisons of C3 and CAM states in facultative CAM species, many fundamental biochemical principles of the CAM pathway have been uncovered. Facultative CAM species will be of even greater relevance now that new sequencing technologies facilitate the mapping of genomes and tracking of the expression patterns of multiple genes. These technologies and facultative CAM systems, when joined, are expected to contribute in a major way towards our goal of understanding the essence of CAM. © The Author 2014. Published by Oxford University Press on behalf of the Society for Experimental Biology. All rights reserved. For permissions, please email: journals.permissions@oup.com.
Galbraith, Niall; Moss, Tim; Galbraith, Victoria; Purewal, Satvinder
2018-08-01
Complementary and alternative medicine (CAM) use is widespread despite the controversy over its effectiveness. Although previous reviews have examined the demographics and attitudes of CAM users, there is no existing review on the traits or cognitions which characterise either CAM users or those who believe in CAM effectiveness. The current systematic review set out to address these gaps in the literature by applying a narrative synthesis. A bibliographic search and manual searches were undertaken and key authors were contacted. Twenty-three papers were selected. The trait openness to experience was positively associated with CAM use but not CAM belief. Absorption and various types of coping were also positively associated with CAM use and belief. No other trait was reliably associated with CAM use or belief. Intuitive thinking and ontological confusions were positively associated with belief in CAM effectiveness; intuitive thinking was also positively associated with CAM use. Studies researching cognitions in CAM use/belief were mostly on non-clinical samples, whilst studies on traits and CAM use/belief were mostly on patients. The quality of studies varied but unrepresentative samples, untested outcome measures and simplistic statistical analyses were the most common flaws. Traits and cognition might be important correlates of CAM use and also of faith in CAM.
Sirois, Fuschia M; Salamonsen, Anita; Kristoffersen, Agnete E
2016-02-24
Research on continued CAM use has been largely atheoretical and has not considered the broader range of psychological and behavioral factors that may be involved. The purpose of this study was to test a new conceptual model of commitment to CAM use that implicates utilitarian (trust in CAM) and symbolic (perceived fit with CAM) in psychological and behavioral dimensions of CAM commitment. A student sample of CAM consumers, (N = 159) completed a survey about their CAM use, CAM-related values, intentions for future CAM use, CAM word-of-mouth behavior, and perceptions of being an ongoing CAM consumer. Analysis revealed that the utilitarian, symbolic, and CAM commitment variables were significantly related, with r's ranging from .54 to .73. A series hierarchical regression analyses controlling for relevant demographic variables found that the utilitarian and symbolic values uniquely accounted for significant and substantial proportion of the variance in each of the three CAM commitment indicators (R(2) from .37 to .57). The findings provide preliminary support for the new model that posits that CAM commitment is a multi-dimensional psychological state with behavioral indicators. Further research with large-scale samples and longitudinal designs is warranted to understand the potential value of the new model.
Performance verification of the FlashCam prototype camera for the Cherenkov Telescope Array
NASA Astrophysics Data System (ADS)
Werner, F.; Bauer, C.; Bernhard, S.; Capasso, M.; Diebold, S.; Eisenkolb, F.; Eschbach, S.; Florin, D.; Föhr, C.; Funk, S.; Gadola, A.; Garrecht, F.; Hermann, G.; Jung, I.; Kalekin, O.; Kalkuhl, C.; Kasperek, J.; Kihm, T.; Lahmann, R.; Marszalek, A.; Pfeifer, M.; Principe, G.; Pühlhofer, G.; Pürckhauer, S.; Rajda, P. J.; Reimer, O.; Santangelo, A.; Schanz, T.; Schwab, T.; Steiner, S.; Straumann, U.; Tenzer, C.; Vollhardt, A.; Wolf, D.; Zietara, K.; CTA Consortium
2017-12-01
The Cherenkov Telescope Array (CTA) is a future gamma-ray observatory that is planned to significantly improve upon the sensitivity and precision of the current generation of Cherenkov telescopes. The observatory will consist of several dozens of telescopes with different sizes and equipped with different types of cameras. Of these, the FlashCam camera system is the first to implement a fully digital signal processing chain which allows for a traceable, configurable trigger scheme and flexible signal reconstruction. As of autumn 2016, a prototype FlashCam camera for the medium-sized telescopes of CTA nears completion. First results of the ongoing system tests demonstrate that the signal chain and the readout system surpass CTA requirements. The stability of the system is shown using long-term temperature cycling.
Monnais, Laurence
2017-02-01
At a time of growing interest in integrative approaches to health and care, this article examines, from a historical perspective, the factors underlying the global popularity of so-called complementary and alternative medicines (CAM). Focusing on the multiple and changing meanings of the concepts used with reference to CAM since the nineteenth century, it emphasizes the agency of CAM practitioners' and calls into question a linear progression from outright exclusion to gradual inclusion into mainstream health care systems. This analysis concludes that biomedicine and "other" medical systems have mutually defined each other in a process of co-production that has had a significant impact on the medicalization of contemporary societies from North America to East Asia. © 2017 médecine/sciences – Inserm.
[Coloration of mica glass ceramic for use in dental CAD/CAM system].
Sun, Ying; Wang, Zhong-yi; Tian, Jie-mo; Cao, Xiao-gang
2003-03-01
An intrinsically colored machinable glass-ceramic containing tetrasilicic fluormica as the predominant crystal phase was studied, which was used in molar crown in dental CAD/CAM system. Orthogonal design analysis was used to select appropriate base formula, coloration and heat treatment process. Factors influencing the color appearance of mica glass ceramic were nucleation agent and the ratio of Mg(2+) to K(+) in base formula; Cerium oxide (CeO(2)) was used as the main coloration; The preferred heat treatment was 650 degrees C for 1 h and 1,000 degrees C or 1,050 degrees C for 3 h - 4 h. This mica glass-ceramic could provide 4 to 5 color appearance for dental use, it showed excellent machinability which was eminently suitable for use in dental CAD/CAM system.
Halling, D. Brent; Kenrick, Sophia A.; Riggs, Austen F.
2014-01-01
Ca2+ activates SK Ca2+-activated K+ channels through the protein Ca2+ sensor, calmodulin (CaM). To understand how SK channels operate, it is necessary to determine how Ca2+ regulates CaM binding to its target on SK. Tagless, recombinant SK peptide (SKp), was purified for binding studies with CaM at low and high Ca2+ concentrations. Composition gradient multi-angle light scattering accurately measures the molar mass, stoichiometry, and affinity of protein complexes. In 2 mM Ca2+, SKp and CaM bind with three different stoichiometries that depend on the molar ratio of SKp:CaM in solution. These complexes include 28 kD 1SKp/1CaM, 39 kD 2SKp/1CaM, and 44 kD 1SKp/2CaM. A 2SKp/2CaM complex, observed in prior crystallographic studies, is absent. At <5 nM Ca2+, 1SKp/1CaM and 2SKp/1CaM were observed; however, 1SKp/2CaM was absent. Analytical ultracentrifugation was used to characterize the physical properties of the three SKp/CaM stoichiometries. In high Ca2+, the sedimentation coefficient is smaller for a 1SKp:1CaM solution than it is for either 2SKp:1CaM or 1SKp:2CaM. At low Ca2+ and at >100 µM protein concentrations, a molar excess of SKp over CaM causes aggregation. Aggregation is not observed in Ca2+ or with CaM in molar excess. In low Ca2+ both 1SKp:1CaM and 1SKp:2CaM solutions have similar sedimentation coefficients, which is consistent with the absence of a 1SKp/2CaM complex in low Ca2+. These results suggest that complexes with stoichiometries other than 2SKp/2CaM are important in gating. PMID:24420768
Halling, D Brent; Kenrick, Sophia A; Riggs, Austen F; Aldrich, Richard W
2014-02-01
Ca(2+) activates SK Ca(2+)-activated K(+) channels through the protein Ca(2+) sensor, calmodulin (CaM). To understand how SK channels operate, it is necessary to determine how Ca(2+) regulates CaM binding to its target on SK. Tagless, recombinant SK peptide (SKp), was purified for binding studies with CaM at low and high Ca(2+) concentrations. Composition gradient multi-angle light scattering accurately measures the molar mass, stoichiometry, and affinity of protein complexes. In 2 mM Ca(2+), SKp and CaM bind with three different stoichiometries that depend on the molar ratio of SKp:CaM in solution. These complexes include 28 kD 1SKp/1CaM, 39 kD 2SKp/1CaM, and 44 kD 1SKp/2CaM. A 2SKp/2CaM complex, observed in prior crystallographic studies, is absent. At <5 nM Ca(2+), 1SKp/1CaM and 2SKp/1CaM were observed; however, 1SKp/2CaM was absent. Analytical ultracentrifugation was used to characterize the physical properties of the three SKp/CaM stoichiometries. In high Ca(2+), the sedimentation coefficient is smaller for a 1SKp:1CaM solution than it is for either 2SKp:1CaM or 1SKp:2CaM. At low Ca(2+) and at >100 µM protein concentrations, a molar excess of SKp over CaM causes aggregation. Aggregation is not observed in Ca(2+) or with CaM in molar excess. In low Ca(2+) both 1SKp:1CaM and 1SKp:2CaM solutions have similar sedimentation coefficients, which is consistent with the absence of a 1SKp/2CaM complex in low Ca(2+). These results suggest that complexes with stoichiometries other than 2SKp/2CaM are important in gating.
Shorofi, Seyed Afshin; Arbon, Paul
2017-05-01
This study was intended to examine CAM among Australian hospital-based nurses, identifying their knowledge, attitude, personal and professional use, reasons for use, CAM referrals, and socio-demographic predictors of CAM users. Nurses holding a qualification in nursing and working in surgical wards were included using a convenience sampling technique. A self-complete questionnaire was developed to achieve the aims of the study. Descriptive and non-parametric statistics were calculated to describe and analyse data. Overall, 95.7% and 49.7% of nurses reported personal and professional use of CAM, respectively. The most popular CAM/CAM domain personally and professionally used by nurses was massage therapy and mind-body therapies. The primary reason for personal use of CAM was "[it] fits into my way of life/philosophy". Furthermore, massage therapists were the most commonly recommended CAM practitioners to patients. Only 15.8% of nurses would always ask patients about use of herbal medicines as part of nursing history taking. Over one-fifth (22.4%) of nurses rated their attitude as having a very positive, and 60.3% rated themselves as having very little or no knowledge of CAM. A positive correlation was also found between knowledge and attitude about CAM. Positive attitude and higher knowledge about CAM were positively correlated to CAM referrals. Several socio-demographic factors predicted personal and professional use of CAM. This study revealed that nurses generally believe not to have sufficient knowledge of CAM but are open to use CAM with patients. Nurses' positive attitude toward and personal use of CAM could be an indication that they are poised for further integration of evidence-based CAM into nursing practice to treat whole person. Copyright © 2017 Elsevier Ltd. All rights reserved.
Lim, Se-Ho; Kim, Yeon-Ho; Kim, Moon-Key; Nam, Woong; Kang, Sang-Hoon
2016-12-01
We examined whether cutting a fibula graft with a surgical guide template, prepared with computer-aided design/computer-aided manufacturing (CAD/CAM), would improve the precision and accuracy of mandibular reconstruction. Thirty mandibular rapid prototype (RP) models were allocated to experimental (N = 15) and control (N = 15) groups. Thirty identical fibular RP models were assigned randomly, 15 to each group. For reference, we prepared a reconstructed mandibular RP model with a three-dimensional printer, based on surgical simulation. In the experimental group, a stereolithography (STL) surgical guide template, based on simulation, was used for cutting the fibula graft. In the control group, the fibula graft was cut manually, with reference to the reconstructed RP mandible model. The mandibular reconstructions were compared to the surgical simulation, and errors were calculated for both the STL surgical guide and the manual methods. The average differences in three-dimensional, minimum distances between the reconstruction and simulation were 9.87 ± 6.32 mm (mean ± SD) for the STL surgical guide method and 14.76 ± 10.34 mm (mean ± SD) for the manual method. The STL surgical guide method incurred less error than the manual method in mandibular reconstruction. A fibula cutting guide improved the precision of reconstructing the mandible with a fibula graft.
Murthy, Vijayendra; Sibbritt, David W; Adams, Jon
2015-08-01
Back pain is the most prevalent of musculoskeletal conditions, and back pain sufferers have been identified as high users of complementary and alternative medicine (CAM). Despite lacking evidence, CAM treatments (e.g., acupuncture, chiropractic, and massage) and CAM products (eg, vitamins, supplements, and aromatherapy oils) for back pain care have become widely available internationally, and CAM use by back pain sufferers has become a significant health service issue. However, to date, there has been no integrative review on CAM use for back pain. This study aims to conduct an integrative review on CAM use for back pain focusing on prevalence of use, commonly used CAM, characteristics of users, factors influencing decision making, self-perceived effectiveness, and communication with health-care providers. The study is based on an integrative literature review. A comprehensive search of international literature from 2000 to 2014 in MEDLINE, CINHAL, AMED, DARE, EMBASE, ExceptaMedica, psycINFO, and SCOPUS databases was conducted. The search was limited to peer-reviewed articles published in English language and reporting empirical research findings on CAM use for back pain. The review reveals a considerable variation in prevalences of CAM use for back pain internationally. Acupuncture, chiropractic, osteopathy, and massage therapy are the commonly used CAM treatments besides a range of self-prescribed CAM, and back pain sufferers use CAM alongside conventional medical treatments. Female gender, chronicity of back pain, and previous exposure to CAM are key predictors of CAM use for back pain as highlighted from the reviewed literature. Family, friends, and recommendation by doctors appear to influence decision making on CAM use for back pain. The review reveals that users of CAM for back pain tend to report CAM as beneficial, but there is little knowledge on communication between CAM users with back pain and health-care providers about such use. Existing literature is largely based on the research investigating CAM use for back pain among a range of other health conditions. Further rigorous research is needed to investigate the use of a wider range of CAM treatments, particularly self-prescribed CAM for back pain. The review findings provide insights for health-care providers and policy makers on the range of CAM treatments used by back pain sufferers. Conventional medical and CAM practitioners should be aware of back pain sufferers' decision making regarding a range of CAM treatments and be prepared to communicate with patients on safe and effective CAM treatments for back pain. Copyright © 2015 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
McCormack, Kenneth J. (Inventor)
2016-01-01
A cryogenic cam butterfly valve has a body that includes an axially extending fluid conduit formed there through. A disc lug is connected to a back side of a valve disc and has a circular bore that receives and is larger than a cam of a cam shaft. The valve disc is rotatable for a quarter turn within the body about a lug axis that is offset from the shaft axis. Actuating the cam shaft in the closing rotational direction first causes the camming side of the cam of the cam shaft to rotate the disc lug and the valve disc a quarter turn from the open position to the closed position. Further actuating causes the camming side of the cam shaft to translate the valve disc into sealed contact with the valve seat. Opening rotational direction of the cam shaft reverses these motions.
Complementary and Alternative Medicine: A Clinical Study in 1,016 Hematology/Oncology Patients.
Hierl, Marina; Pfirstinger, Jochen; Andreesen, Reinhard; Holler, Ernst; Mayer, Stephanie; Wolff, Daniel; Vogelhuber, Martin
2017-01-01
Surveys state a widespread use of complementary and alternative medicine (CAM) in patients with malignant diseases. CAM methods might potentially interfere with the metabolization of tumor-specific therapy. However, there is little communication about CAM use in hematology/oncology patients between patients, CAM providers, and oncologists. A self-administered questionnaire was handed out to all patients attending to the hematology/oncology outpatient clinic of Regensburg University Hospital. Subsequently, a chart review of all CAM users was performed. Questionnaires of 1,016 patients were analyzed. Of these patients, 30% used CAM, preferably vitamins and micronutrients. Main information sources for CAM methods were physicians/nonmedical practitioners and friends/relatives. CAM therapies were provided mainly by licensed physicians (29%), followed by nonmedical practitioners (14%) and the patients themselves (13%). Although 62% of the CAM users agreed that the oncologist may know about their CAM therapy, a chart entry about CAM use was found only in 41%. CAM is frequently used by hematology/oncology patients. Systematic communication about CAM is essential to avoid possible drug interactions. © 2017 S. Karger AG, Basel.
CAM practitioners in the Australian health workforce: an underutilized resource
2012-01-01
Background CAM practitioners are a valuable but underutilizes resource in Australian health care. Despite increasing public support for complementary and alternative medicine (CAM) little is known about the CAM workforce. Apart from the registered professions of chiropractic, osteopathy and Chinese medicine, accurate information about the number of CAM practitioners in the workforce has been difficult to obtain. It appears that many non-registered CAM practitioners, although highly qualified, are not working to their full capacity. Discussion Increasing public endorsement of CAM stands in contrast to the negative attitude toward the CAM workforce by some members of the medical and other health professions and by government policy makers. The marginalisation of the CAM workforce is evident in prejudicial attitudes held by some members of the medical and other health professions and its exclusion from government policy making. Inconsistent educational standards has meant that non-registered CAM practitioners, including highly qualified and competent ones, are frequently overlooked. Legitimising their contribution to the health workforce could alleviate workforce shortages and provide opportunities for redesigned job roles and new multidisciplinary teams. Priorities for better utilisation of the CAM workforce include establishing a guaranteed minimum education standard for more CAM occupation groups through national registration, providing interprofessional education that includes CAM practitioners, developing courses to upgrade CAM practitioners' professional skills in areas of indentified need, and increasing support for CAM research. Summary Marginalisation of the CAM workforce has disadvantaged those qualified and competent CAM practitioners who practise evidence-informed medicine on the basis of many years of university training. Legitimising and expanding the important contribution of CAM practitioners could alleviate projected health workforce shortages, particularly for the prevention and management of chronic health conditions and for health promotion. PMID:23116374
CAM practitioners in the Australian health workforce: an underutilized resource.
Grace, Sandra
2012-11-02
CAM practitioners are a valuable but underutilizes resource in Australian health care. Despite increasing public support for complementary and alternative medicine (CAM) little is known about the CAM workforce. Apart from the registered professions of chiropractic, osteopathy and Chinese medicine, accurate information about the number of CAM practitioners in the workforce has been difficult to obtain. It appears that many non-registered CAM practitioners, although highly qualified, are not working to their full capacity. Increasing public endorsement of CAM stands in contrast to the negative attitude toward the CAM workforce by some members of the medical and other health professions and by government policy makers. The marginalisation of the CAM workforce is evident in prejudicial attitudes held by some members of the medical and other health professions and its exclusion from government policy making. Inconsistent educational standards has meant that non-registered CAM practitioners, including highly qualified and competent ones, are frequently overlooked. Legitimising their contribution to the health workforce could alleviate workforce shortages and provide opportunities for redesigned job roles and new multidisciplinary teams. Priorities for better utilisation of the CAM workforce include establishing a guaranteed minimum education standard for more CAM occupation groups through national registration, providing interprofessional education that includes CAM practitioners, developing courses to upgrade CAM practitioners' professional skills in areas of indentified need, and increasing support for CAM research. Marginalisation of the CAM workforce has disadvantaged those qualified and competent CAM practitioners who practise evidence-informed medicine on the basis of many years of university training. Legitimising and expanding the important contribution of CAM practitioners could alleviate projected health workforce shortages, particularly for the prevention and management of chronic health conditions and for health promotion.
2014-01-01
Background Race has been reported to affect the use of complementary and alternative medicine (CAM), but there is very little research on the use of CAM by ethnicity in Korea. This study explores the prevalence of CAM use among ethnic minorities in South Korea. Methods The design is a descriptive and cross-sectional study. A convenience sample of ethnic minorities was recruited from two public healthcare centres in Gyeonggi province. The survey instrument included 37 questions regarding CAM use, factors influencing use of CAM, self-health management, and the socio-demographic profile of study participants. Results Sixty-two percent of study participants reported the use of CAM. Multivitamins (53.3%), acupuncture (48.9%), and traditional Korean herbal medicine (38.9%) were popular CAM modalities in our sample. Other notable CAM modalities included herbal plants, therapeutic massage, and moxibustion therapy. The majority of CAM users (52.2%) received CAM services to treat diseases or as a secondary treatment while receiving conventional care. Having positive perceptions toward the effectiveness of CAM was a major determining factor in CAM use. Conclusions Physicians need to be aware of the fact that many ethnic minorities use CAM therapies. Many CAM users reported that they want doctors to know about their CAM use and have a basic understanding of traditional medicine in their home country. Overcoming language and cultural barriers will help reduce unwanted medical complications. High prevalence of CAM use among ethnic minorities in our study warrants further studies using larger sample population. PMID:24641983
Microwave processing of a dental ceramic used in computer-aided design/computer-aided manufacturing.
Pendola, Martin; Saha, Subrata
2015-01-01
Because of their favorable mechanical properties and natural esthetics, ceramics are widely used in restorative dentistry. The conventional ceramic sintering process required for their use is usually slow, however, and the equipment has an elevated energy consumption. Sintering processes that use microwaves have several advantages compared to regular sintering: shorter processing times, lower energy consumption, and the capacity for volumetric heating. The objective of this study was to test the mechanical properties of a dental ceramic used in computer-aided design/computer-aided manufacturing (CAD/CAM) after the specimens were processed with microwave hybrid sintering. Density, hardness, and bending strength were measured. When ceramic specimens were sintered with microwaves, the processing times were reduced and protocols were simplified. Hardness was improved almost 20% compared to regular sintering, and flexural strength measurements suggested that specimens were approximately 50% stronger than specimens sintered in a conventional system. Microwave hybrid sintering may preserve or improve the mechanical properties of dental ceramics designed for CAD/CAM processing systems, reducing processing and waiting times.
Science of active galactic nuclei with the GTC and CanariCam
NASA Astrophysics Data System (ADS)
Levenson, Nancy A.; Packham, Christopher C.; Alonso-Herrero, Almudena; Aretxaga, Itziar; Colina, Luis; Díaz-Santos, Tanio; Elitzur, Moshe; Mason, Rachel E.; Perlman, Eric S.; Radomski, James T.; Roche, Patrick F.; Rodríguez Espinosa, José Miguel; Young, Stuart; Telesco, Charles M.
2008-07-01
CanariCam is the facility mid-infrared (MIR) instrument for the Gran Telescopio Canarias (GTC), a 10.4m telescope at the Observatorio del Roque de los Muchachos on La Palma. One of the science drivers for CanariCam is the study of active galactic nuclei (AGN). We will exploit the instrument's high sensitivity in imaging, spectroscopy, and polarimetry modes to answer fundamental questions of AGN and their host galaxies. Dust in the nucleus of an active galaxy reprocesses the intrinsic radiation of the central engine to emerge in the MIR. Current work demonstrates that the hot dust immediately associated with the AGN, which blocks direct views of the AGN from some lines of sight, is confined to small (parsec) scales. Thus, high spatial resolution is essential to probe the "torus" of unified AGN models separate from the host galaxy. CanariCam provides a 0.08" pixel scale for Nyquist sampling the diffraction-limited point spread function at 8μm, and narrow (0.2") spectroscopy slits (with R=120-1300). New observations with the GTC/CanariCam will provide key constraints on the physical conditions in the clumpy torus, and we will sensitively determine AGN obscuration as a function of nuclear activity. We will therefore address the fueling process and its relationship to the torus, the interaction with the host galaxy, and dust chemistry. These data will be essential preparation for the next generation of telescopes that will observe the distant universe directly to explore galaxy and black hole formation and evolution, and the GTC/CanariCam system uniquely provides multiple modes to probe AGN.
Rahbar, Mohammad H.; Wyatt, Gwen; Sikorskii, Alla; Victorson, David; Ardjomand-Hessabi, Manouchehr
2011-01-01
Background Multisite randomized clinical trials allow for increased research collaboration among investigators and expedite data collection efforts. As a result, government funding agencies typically look favorably upon this approach. As the field of complementary and alternative medicine (CAM) continues to evolve, so do increased calls for the use of more rigorous study design and trial methodologies, which can present challenges for investigators. Purpose To describe the processes involved in the coordination and management of a multisite randomized clinical trial of a CAM intervention. Methods Key aspects related to the coordination and management of a multisite CAM randomized clinical trial are presented, including organizational and site selection considerations, recruitment concerns and issues related to data collection and randomization to treatment groups. Management and monitoring of data, as well as quality assurance procedures are described. Finally, a real world perspective is shared from a recently conducted multisite randomized clinical trial of reflexology for women diagnosed with advanced breast cancer. Results The use of multiple sites in the conduct of CAM-based randomized clinical trials can provide an efficient, collaborative and robust approach to study coordination and data collection that maximizes efficiency and ensures the quality of results. Conclusions Multisite randomized clinical trial designs can offer the field of CAM research a more standardized and efficient approach to examine the effectiveness of novel therapies and treatments. Special attention must be given to intervention fidelity, consistent data collection and ensuring data quality. Assessment and reporting of quantitative indicators of data quality should be required. PMID:21664296
NASA Astrophysics Data System (ADS)
Zhou, Cheng; Penner, Joyce E.
2017-01-01
Observation-based studies have shown that the aerosol cloud lifetime effect or the increase of cloud liquid water path (LWP) with increased aerosol loading may have been overestimated in climate models. Here, we simulate shallow warm clouds on 27 May 2011 at the southern Great Plains (SGP) measurement site established by the Department of Energy's (DOE) Atmospheric Radiation Measurement (ARM) program using a single-column version of a global climate model (Community Atmosphere Model or CAM) and a cloud resolving model (CRM). The LWP simulated by CAM increases substantially with aerosol loading while that in the CRM does not. The increase of LWP in CAM is caused by a large decrease of the autoconversion rate when cloud droplet number increases. In the CRM, the autoconversion rate is also reduced, but this is offset or even outweighed by the increased evaporation of cloud droplets near the cloud top, resulting in an overall decrease in LWP. Our results suggest that climate models need to include the dependence of cloud top growth and the evaporation/condensation process on cloud droplet number concentrations.
Neuronal Target Identification Requires AHA-1-Mediated Fine-Tuning of Wnt Signaling in C. elegans
Zhang, Jingyan; Li, Xia; Jevince, Angela R.; Guan, Liying; Wang, Jiaming; Hall, David H.; Huang, Xun; Ding, Mei
2013-01-01
Electrical synaptic transmission through gap junctions is a vital mode of intercellular communication in the nervous system. The mechanism by which reciprocal target cells find each other during the formation of gap junctions, however, is poorly understood. Here we show that gap junctions are formed between BDU interneurons and PLM mechanoreceptors in C. elegans and the connectivity of BDU with PLM is influenced by Wnt signaling. We further identified two PAS-bHLH family transcription factors, AHA-1 and AHR-1, which function cell-autonomously within BDU and PLM to facilitate the target identification process. aha-1 and ahr-1 act genetically upstream of cam-1. CAM-1, a membrane-bound receptor tyrosine kinase, is present on both BDU and PLM cells and likely serves as a Wnt antagonist. By binding to a cis-regulatory element in the cam-1 promoter, AHA-1 enhances cam-1 transcription. Our study reveals a Wnt-dependent fine-tuning mechanism that is crucial for mutual target cell identification during the formation of gap junction connections. PMID:23825972
NASA Astrophysics Data System (ADS)
Gabor, A.; Jivanescu, A.; Zaharia, C.; Hategan, S.; Topala, F. I.; Levai, C. M.; Negrutiu, M. L.; Sinescu, C.; Duma, V.-F.; Bradu, A.; Podoleanu, A. Gh.
2016-03-01
Digital impressions were introduced to overcome some of the obstacles due to traditional impression materials and techniques. The aim of this in vitro study is to compare the accuracy of all ceramic crowns obtained with digital impression and CAD-CAM technology with the accuracy of those obtained with conventional impression techniques. Two groups of 10 crowns each have been considered. The digital data obtained from Group 1 have been processed and the all-ceramic crowns were milled with a CAD/CAM technology (CEREC MCX, Sirona). The all ceramic crowns in Group 2 were obtained with the classical technique of pressing (emax, Ivoclar, Vivadent). The evaluation of the marginal adaptation was performed with Time Domain Optical Coherence Tomography (TD OCT), working at a wavelength of 1300 nm. Tri-dimensional (3D) reconstructions of the selected areas were obtained. Based on the findings in this study, one may conclude that the marginal accuracy of all ceramic crowns fabricated with digital impression and the CAD/CAM technique is superior to the conventional impression technique.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma, Po-Lun; Gattiker, J. R.; Liu, Xiaohong
2013-06-27
A Gaussian process (GP) emulator is applied to quantify the contribution of local and remote emissions of black carbon (BC) on the BC concentrations in different regions using a Latin Hypercube sampling strategy for emission perturbations in the offline version of the Community Atmosphere Model Version 5.1 (CAM5) simulations. The source-receptor relationships are computed based on simulations constrained by a standard free-running CAM5 simulation and the ERA-Interim reanalysis product. The analysis demonstrates that the emulator is capable of retrieving the source-receptor relationships based on a small number of CAM5 simulations. Most regions are found susceptible to their local emissions. Themore » emulator also finds that the source-receptor relationships retrieved from the model-driven and the reanalysis-driven simulations are very similar, suggesting that the simulated circulation in CAM5 resembles the assimilated meteorology in ERA-Interim. The robustness of the results provides confidence for applying the emulator to detect dose-response signals in the climate system.« less
Apo calmodulin binding to the L-type voltage-gated calcium channel Ca{sub v}1.2 IQ peptide
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lian Luyun; Myatt, Daniel; Kitmitto, Ashraf
2007-02-16
The influx of calcium through the L-type voltage-gated calcium channels (LTCCs) is the trigger for the process of calcium-induced calcium release (CICR) from the sarcoplasmic recticulum, an essential step for cardiac contraction. There are two feedback mechanisms that regulate LTCC activity: calcium-dependent inactivation (CDI) and calcium-dependent facilitation (CDF), both of which are mediated by calmodulin (CaM) binding. The IQ domain (aa 1645-1668) housed within the cytoplasmic domain of the LTCC Ca{sub v}1.2 subunit has been shown to bind both calcium-loaded (Ca{sup 2+}CaM ) and calcium-free CaM (apoCaM). Here, we provide new data for the structural basis for the interaction ofmore » apoCaM with the IQ peptide using NMR, revealing that the apoCaM C-lobe residues are most significantly perturbed upon complex formation. In addition, we have employed transmission electron microscopy of purified LTCC complexes which shows that both apoCaM and Ca{sup 2+}CaM can bind to the intact channel.« less
1997-04-01
implied, with respect to the accuracy, completeness or usefulness of the information contained in this report/ manual , or that the use of any information...shipyards throughout the world have introduced various aspects of CAD/CAM piecemeal as substitutes for manual processes, the greatest improvement in...possibility of multiple models of the molded geometry being developed, which would cause the loss of geometry control. Numerous AutoLisp routines were used
Vane Pump Casing Machining of Dumpling Machine Based on CAD/CAM
NASA Astrophysics Data System (ADS)
Huang, Yusen; Li, Shilong; Li, Chengcheng; Yang, Zhen
Automatic dumpling forming machine is also called dumpling machine, which makes dumplings through mechanical motions. This paper adopts the stuffing delivery mechanism featuring the improved and specially-designed vane pump casing, which can contribute to the formation of dumplings. Its 3D modeling in Pro/E software, machining process planning, milling path optimization, simulation based on UG and compiling post program were introduced and verified. The results indicated that adoption of CAD/CAM offers firms the potential to pursue new innovative strategies.
CAD/CAM complete dentures: a review of two commercial fabrication systems.
Kattadiyil, Mathew T; Goodacre, Charles J; Baba, Nadim Z
2013-06-01
The use of computer-aided design and computer-aided manufacturing (CAD/CAM) has become available for complete dentures through the AvaDent and Dentca systems. AvaDent uses laser scanning and computer technology. Teeth are arranged and bases formed using proprietary software.The bases are milled from prepolymerized pucks of resin. Dentca uses computer software to produce virtual maxillary and mandibular edentulous ridges, arrange the teeth and form bases. The dentures are fabricated using a conventional processing technique.
Ciocca, L.; Donati, D.; Ragazzini, S.; Dozza, B.; Rossi, F.; Fantini, M.; Spadari, A.; Romagnoli, N.; Landi, E.; Tampieri, A.; Piattelli, A.; Iezzi, G.; Scotti, R.
2013-01-01
Purpose. This study evaluated the efficacy of a regenerative approach using mesenchymal stem cells (MSCs) and CAD-CAM customized pure and porous hydroxyapatite (HA) scaffolds to replace the temporomandibular joint (TMJ) condyle. Methods. Pure HA scaffolds with a 70% total porosity volume were prototyped using CAD-CAM technology to replace the two temporomandibular condyles (left and right) of the same animal. MSCs were derived from the aspirated iliac crest bone marrow, and platelets were obtained from the venous blood of the sheep. Custom-made surgical guides were created by direct metal laser sintering and were used to export the virtual planning of the bone cut lines into the surgical environment. Sheep were sacrificed 4 months postoperatively. The HA scaffolds were explanted, histological specimens were prepared, and histomorphometric analysis was performed. Results. Analysis of the porosity reduction for apposition of newly formed bone showed a statistically significant difference in bone formation between condyles loaded with MSC and condyles without (P < 0.05). The bone ingrowth (BI) relative values of split-mouth comparison (right versus left side) showed a significant difference between condyles with and without MSCs (P < 0.05). Analysis of the test and control sides in the same animal using a split-mouth study design was performed; the condyle with MSCs showed greater bone formation. Conclusion. The split-mouth design confirmed an increment of bone regeneration into the HA scaffold of up to 797% upon application of MSCs. PMID:24073409
A Methodological Review and Critique of the "Intergenerational Transmission of Violence" Literature.
Haselschwerdt, Megan L; Savasuk-Luxton, Rachel; Hlavaty, Kathleen
2017-01-01
Exposure to interpersonal or interparental violence (EIPV) and child abuse and maltreatment (CAM) are associated with an increased risk of maladaptive outcomes, including later involvement in adulthood intimate partner violence (IPV; often referred to as the theory of intergenerational transmission of violence). Recent meta-analyses, however, have documented a weak effect size when examining this association. By focusing on young adulthood, a development stage in which identity development and romantic relationship formation are salient tasks, we can provide insight into the association between EIPV, CAM, and IPV. Guided by the methodological critiques from the IPV and EIPV literatures, the present study reviewed the methodology used in 16 studies (published between 2002 and 2016) that tested the theory of intergenerational transmission of violence. The review study focused on how EIPV, CAM, and young adult dating violence were measured and analyzed, with the initial goal of better understanding how methodological decision informed the study's findings. Ultimately, we determined that there was simply too much methodological variability and yet too little methodological complexity to truly inform a review and discussion of the results; therefore, our review solely focused on the study's methodological decisions. Based on our review, we suggest that both of these challenges, too much variability and too little complexity, hinder our ability to examine the theory of intergenerational transmission of violence. Future research must strike a balance between methodological consistency and complexity to better understand the intricate nuances of IPV experiences and inform practice.
Ciocca, L; Donati, D; Ragazzini, S; Dozza, B; Rossi, F; Fantini, M; Spadari, A; Romagnoli, N; Landi, E; Tampieri, A; Piattelli, A; Iezzi, G; Scotti, R
2013-01-01
This study evaluated the efficacy of a regenerative approach using mesenchymal stem cells (MSCs) and CAD-CAM customized pure and porous hydroxyapatite (HA) scaffolds to replace the temporomandibular joint (TMJ) condyle. Pure HA scaffolds with a 70% total porosity volume were prototyped using CAD-CAM technology to replace the two temporomandibular condyles (left and right) of the same animal. MSCs were derived from the aspirated iliac crest bone marrow, and platelets were obtained from the venous blood of the sheep. Custom-made surgical guides were created by direct metal laser sintering and were used to export the virtual planning of the bone cut lines into the surgical environment. Sheep were sacrificed 4 months postoperatively. The HA scaffolds were explanted, histological specimens were prepared, and histomorphometric analysis was performed. Analysis of the porosity reduction for apposition of newly formed bone showed a statistically significant difference in bone formation between condyles loaded with MSC and condyles without (P < 0.05). The bone ingrowth (BI) relative values of split-mouth comparison (right versus left side) showed a significant difference between condyles with and without MSCs (P < 0.05). Analysis of the test and control sides in the same animal using a split-mouth study design was performed; the condyle with MSCs showed greater bone formation. The split-mouth design confirmed an increment of bone regeneration into the HA scaffold of up to 797% upon application of MSCs.
Singh, Vimal; Raidoo, Deshandra M; Harries, Catherine S
2004-02-04
The purpose of this study was to determine, among the Indian community of Chatsworth, South Africa, the prevalence and utilisation patterns of complementary and alternative medicine (CAM), attitudes associated with CAM use and communication patterns of CAM users with their primary care doctors. Face-to-face structured interviews were conducted in Chatsworth, a suburb of Durban in which South Africans of Indian origin predominantly reside. Participants were 200 randomly selected adult English-speaking Indian residents. The prevalence of CAM usage for period 2000/2001 was 38.5% (95% confidence interval 31.7% to 45.6%). Spiritual healing and herbal/natural medicines, including vitamins were the most common types of CAM used, accounting for 42.8% and 48.1% respectively of overall CAM usage. People used CAM to treat conditions including diabetes mellitus, headaches, arthritis and joint pains, stress, skin disorders, backaches, hypertension and nasal disorders. Half of the CAM users used allopathic medicines concurrently. The cost of CAM utilization over this 1-year period, incurred by 80.5% of users for the duration of therapy for their most troublesome condition was below R500 (approximately US50 dollars). Age, sex, marital status, religion, level of education and income were shown not to influence the use of CAM. Greater than half (51.9%) of CAM users did so either upon the advice of someone they knew, or after noticing a CAM advertisement in the local press. Seventy-nine percent of CAM users indicated that they had positive outcomes with their treatments. Fifty four percent of CAM users (excluding those using spiritual healing only) failed to inform their doctors that they used CAM. The main reason given by half of this group was that informing their doctors did not seem necessary. The prevalence of CAM in Chatsworth is similar to findings in other parts of the world. Although CAM was used to treat many different ailments, this practice could not be attributed to any particular demographic profile. The majority of CAM users were satisfied with the effects of CAM. Findings support a need for greater integration of allopathic medicine and CAM, as well as improved communication between patients and caregivers regarding CAM usage.
Singh, Vimal; Raidoo, Deshandra M; Harries, Catherine S
2004-01-01
Background The purpose of this study was to determine, among the Indian community of Chatsworth, South Africa, the prevalence and utilisation patterns of complementary and alternative medicine (CAM), attitudes associated with CAM use and communication patterns of CAM users with their primary care doctors. Methods Face-to-face structured interviews were conducted in Chatsworth, a suburb of Durban in which South Africans of Indian origin predominantly reside. Participants were 200 randomly selected adult English-speaking Indian residents. Results The prevalence of CAM usage for period 2000/2001 was 38.5% (95% confidence interval 31.7% to 45.6%). Spiritual healing and herbal/natural medicines, including vitamins were the most common types of CAM used, accounting for 42.8% and 48.1% respectively of overall CAM usage. People used CAM to treat conditions including diabetes mellitus, headaches, arthritis and joint pains, stress, skin disorders, backaches, hypertension and nasal disorders. Half of the CAM users used allopathic medicines concurrently. The cost of CAM utilization over this 1-year period, incurred by 80.5% of users for the duration of therapy for their most troublesome condition was below R500 (approximately US$50). Age, sex, marital status, religion, level of education and income were shown not to influence the use of CAM. Greater than half (51.9%) of CAM users did so either upon the advice of someone they knew, or after noticing a CAM advertisement in the local press. Seventy-nine percent of CAM users indicated that they had positive outcomes with their treatments. Fifty four percent of CAM users (excluding those using spiritual healing only) failed to inform their doctors that they used CAM. The main reason given by half of this group was that informing their doctors did not seem necessary. Conclusion The prevalence of CAM in Chatsworth is similar to findings in other parts of the world. Although CAM was used to treat many different ailments, this practice could not be attributed to any particular demographic profile. The majority of CAM users were satisfied with the effects of CAM. Findings support a need for greater integration of allopathic medicine and CAM, as well as improved communication between patients and caregivers regarding CAM usage. PMID:15018622
Brinkhaus, Benno; Lewith, George; Rehberg, Benno; Heusser, Peter; Cummings, Mike; Michalsen, Andreas; Teut, Michael; Willich, Stefan N; Irnich, Dominik
2011-02-01
Complementary and alternative medicine (CAM) is frequently used in patients in industrialised countries. Despite this popularity, there remains a considerable deficit of discourse and cooperation between physicians practicing CAM and conventional medicine. The aim is to present the methodology and results of the first international case conference on integrative medicine (IM) dealing with a patient with low back pain. In this paper the methodological tool "case conference on IM" is also described. The interactive case conference took place on November 20th, 2009 as part of the "2nd European Congress of IM" in Berlin, Germany. An experienced expert panel from both conventional medicine and CAM developed integrative medical diagnoses and therapeutic strategies using as their starting point an individual patient case on chronic low back pain (LBP). The case was selected because LBP is a common diagnosis with considerable economic impact and a problem which is often treated with CAM. In this case conference, the expert panel agreed on a diagnosis of "chronic non-specific LBP with somatic and psychological factors" and proposed multi-modal short- and long-term treatment including of CAM. The importance of the patient-physician-relationship and the consultation process with appropriate consultation time for treatment success was highlighted. There was consensus that the diagnostic process and resulting treatment plan should be individualised and focussed on the patient as a complete person, identifying the significance the disease has for the patient and not just on the disease for itself. Considerable differences were found amongst the experts regarding the first steps of treatment and each expert saw possibilities of "effective and adequate treatment" being met by their own individual treatment method. The case conference on integrative medicine stimulated an intensive exchange between the approaches used by conventional medicine and CAM clarifying different treatment possibilities for low back pain. Therefore, case conferences on integrative medicine could serve as a model for evaluating similar activities in academic hospitals and establishing such approaches in routine medical care. This strategy has the potential to improve patient centred care. Copyright © 2010 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Caves, J. K.; Bodner, G.; Simms, K.; Fisher, L.; Robertson, T.
2012-12-01
There is growing recognition that public lands cannot be managed as islands; rather, land management must address the ecological, social, and temporal complexity that often spans jurisdictions and traditional planning horizons. Collaborative decision-making and adaptive management (CAM) have been promoted as methods to reconcile competing societal demands and respond to complex ecosystem dynamics. We present the experiences of land managers and stakeholders in using CAM at Las Cienegas National Conservation Area (LCNCA), a highly valued site under the jurisdiction of the Bureau of Land Management (BLM). The CAM process at Las Cienegas is marked by strong stakeholder engagement, with four core elements: 1) shared watershed goals with measurable resource objectives; 2) mechanisms to incorporate new information into decision-making; 3) efforts to make information increasingly relevant and reliable; and 4) shared learning to improve both the process and management actions. The combination of stakeholder engagement and adaptive management has led to agreement on contentious issues, more innovative solutions, and more effective land management. Yet the region is now experiencing rapid changes outside managers' control—including climate change, human population growth, and reduced federal budgets—with large but unpredictable impacts on natural resources. While CAM experience provides a strong foundation for making the difficult and contentious management decisions that such changes are likely to require, neither collaboration nor adaptive management provides a sufficient structure for addressing uncontrollable and unpredictable change. As a result, LCNCA is exploring two specific modifications to CAM that may better address emerging challenges, including: 1) Creating nested resource objectives to distinguish between those objectives which may be crucial from those which may hinder a flexible response to climate change, and 2) Incorporating scenario planning into CAM to explore how climate change may interact with other drivers and alter options for the future, to identify robust management, and to prioritize ecological monitoring efforts. The experiences at LCNCA demonstrate how collaboration and adaptive management can be used to improve social and environmental outcomes and, with a few modifications, may help address the complexity and change that threatens to overwhelm even the best efforts to sustain public lands.
Greenlee, Heather; Neugut, Alfred I; Falci, Laura; Hillyer, Grace Clarke; Buono, Donna; Mandelblatt, Jeanne S; Roh, Janise M; Ergas, Isaac J; Kwan, Marilyn L; Lee, Marion; Tsai, Wei Yann; Shi, Zaixing; Lamerato, Lois; Kushi, Lawrence H; Hershman, Dawn L
2016-09-01
Not all women initiate clinically indicated breast cancer adjuvant treatment. It is important for clinicians to identify women at risk for noninitiation. To determine whether complementary and alternative medicine (CAM) use is associated with decreased breast cancer chemotherapy initiation. In this multisite prospective cohort study (the Breast Cancer Quality of Care [BQUAL] study) designed to examine predictors of breast cancer treatment initiation and adherence, 685 women younger than 70 years with nonmetastatic invasive breast cancer were recruited from Columbia University Medical Center, Kaiser Permanente Northern California, and Henry Ford Health System and enrolled between May 2006 and July 31, 2010. Overall, 306 patients (45%) were clinically indicated to receive chemotherapy per National Comprehensive Cancer Network guidelines. Participants were followed for up to 12 months. Baseline interviews assessed current use of 5 CAM modalities (vitamins and/or minerals, herbs and/or botanicals, other natural products, mind-body self-practice, mind-body practitioner-based practice). CAM use definitions included any use, dietary supplement use, mind-body use, and a CAM index summing the 5 modalities. Chemotherapy initiation was assessed via self-report up to 12 months after baseline. Multivariable logistic regression models examined a priori hypotheses testing whether CAM use was associated with chemotherapy initiation, adjusting for demographic and clinical covariates, and delineating groups by age and chemotherapy indication. A cohort of 685 women younger than 70 years (mean age, 59 years; median age, 59 years) with nonmetastatic invasive breast cancer were recruited and followed for up to 12 months to examine predictors of breast cancer treatment initiation. Baseline CAM use was reported by 598 women (87%). Chemotherapy was initiated by 272 women (89%) for whom chemotherapy was indicated, compared with 135 women (36%) for whom chemotherapy was discretionary. Among women for whom chemotherapy was indicated, dietary supplement users and women with high CAM index scores were less likely than nonusers to initiate chemotherapy (odds ratio [OR], 0.16; 95% CI, 0.03-0.51; and OR per unit, 0.64; 95% CI, 0.46-0.87, respectively). Use of mind-body practices was not related to chemotherapy initiation (OR, 1.45; 95% CI, 0.57-3.59). There was no association between CAM use and chemotherapy initiation among women for whom chemotherapy was discretionary. CAM use was high among patients with early-stage breast cancer enrolled in a multisite prospective cohort study. Current dietary supplement use and higher number of CAM modalities used but not mind-body practices were associated with decreased initiation of clinically indicated chemotherapy. Oncologists should consider discussing CAM with their patients during the chemotherapy decision-making process.
Nuclear Storage Overpack Door Actuator and Alignment Apparatus
Andreyko, Gregory M.
2005-05-11
The invention is a door actuator and alignment apparatus for opening and closing the 15,000-pound horizontally sliding door of a storage overpack. The door actuator includes a ball screw mounted horizontally on a rigid frame including a pair of door panel support rails. An electrically powered ball nut moves along the ball screw. The ball nut rotating device is attached to a carriage. The carriage attachment to the sliding door is horizontally pivoting. Additional alignment features include precision cam followers attached to the rails and rail guides attached to the carriage.
Nuclear storage overpack door actuator and alignment apparatus
Andreyko, Gregory M.
2005-05-10
The invention is a door actuator and alignment apparatus for opening and closing the 15,000-pound horizontally sliding door of a storage overpack. The door actuator includes a ball screw mounted horizontally on a rigid frame including a pair of door panel support rails. An electrically powered ball nut moves along the ball screw. The ball nut rotating device is attached to a carriage. The carriage attachment to the sliding door is horizontally pivoting. Additional alignment features include precision cam followers attached to the rails and rail guides attached to the carriage.
JunoCam Outreach: Lessons Learned from Juno's Earth Flyby
NASA Astrophysics Data System (ADS)
Hansen, C. J.; Caplinger, M. A.; Ravine, M. A.
2014-12-01
The JunoCam visible imager is on the Juno spacecraft explicitly to include the public in the operation of a spacecraft instrument at Jupiter. Amateur astronomers will provide images in 2015 and 2016, as the spacecraft approaches Jupiter, to be used for planning purposes, and also during the mission to provide context for JunoCam's high-resolution pictures. Targeted imaging of specific features would enhance science value, but the dynamic nature of the jovian atmosphere makes this almost completely dependent on ground-based observations. The public will be involved in the decision of which images to acquire in each perijove pass. Partnership with the amateur image processing community will be essential for processing images during the Juno mission. This piece of the virtual team plan was successfully carried out as Juno executed its earth flyby gravity assist in 2013. Although we will have a professional ops team at Malin Space Science Systems, the tiny size of the team overall means that the public participation is not just an extra - it is essential to our success.
Raszeja, V M; Jordens, C F C; Kerridge, I H
2013-01-01
To examine policies and practices relating to the provision, prescription and monitoring of complementary and alternative medicine and therapies (CAM) in conventional cancer services in NSW. Self-administered questionnaire sent to directors of all 65 eligible cancer services in NSW in 2009. Forty-three services responded to the survey (response rate 66%). Only six (14%) services reported having formal policies about CAM. Most (n = 33, 77%) expected that patients would be asked about CAM use during their initial assessment. Eight services (19%) provided and/or prescribed CAM for patients, and most of these (n = 7) recorded details of CAM use in patients' records. Only four (9%) services permitted CAM practitioners from the community to attend inpatients, whereas 24 (56%) permitted inpatients to bring in their own CAM. Most of these services (n = 17) required medical approval for the use of CAM. Of the latter, most (n = 13) recorded the use of approved CAM, but only seven recorded use of unapproved CAM and only three refused permission to continue use of unapproved CAM. Most cancer services in NSW recognise potential CAM use by patients and expect medical staff to ask patients about their use of CAM. While few cancer services provided or prescribed CAM, over half permitted inpatients to bring their own CAM into hospital. There was little control over the use of CAM, however, and monitoring was lax. Given the wide usage of CAM by patients with cancer, this lack of control may compromise clinical outcomes, with potentially dangerous consequences. © 2013 The Authors; Internal Medicine Journal © 2013 Royal Australasian College of Physicians.
Liu, Chenglong; Yang, Yang; Gange, Stephen J; Weber, Kathleen; Sharp, Gerald B; Wilson, Tracey E; Levine, Alexandra; Robison, Esther; Goparaju, Lakshmi; Gandhi, Monica; Ganhdi, Monica; Merenstein, Dan
2009-11-01
To determine prevalence and predictors of complementary and alternative medicine (CAM) use disclosure to health care providers and whether CAM use disclosure is associated with highly active antiretroviral therapy (HAART) adherence among HIV-infected women, we analyzed longitudinal data collected between October 1994 and March 2002 from HIV-infected CAM-using women enrolled in the Women's Interagency HIV Study. Repeated measures Poisson regression models were constructed to evaluate associations of selected predictors with CAM use disclosure and association between CAM use disclosure and HAART adherence. A total of 1,377 HIV-infected women reported CAM use during study follow-up and contributed a total of 4,689 CAM-using person visits. The overall prevalence of CAM use disclosure to health care providers was 36% across study visits. Women over 45 years old, with a college education, or with health insurance coverage were more likely to disclose their CAM use to health care providers, whereas women identified as non-Hispanic Black or other ethnicities were less likely to communicate their CAM usage. More health care provider visits, more CAM domains used, and higher health care satisfaction scores had significant relationships with increased levels of CAM use disclosure. Restricting analysis to use of herbal or nonherbal medications only, similar results were obtained. Compared to other CAM domains, mind-body practice had the lowest prevalence of CAM use disclosure. Additionally, CAM use disclosure was significantly associated with higher HAART adherence. From this study, we showed that a high percentage of HIV-infected women did not discuss their CAM use with health care providers. Interventions targeted towards both physicians and patients may enhance communication of CAM use, avoid potential adverse events and drug interactions, and enhance HAART adherence.
Yang, Yang; Gange, Stephen J.; Weber, Kathleen; Sharp, Gerald B.; Wilson, Tracey E.; Levine, Alexandra; Robison, Esther; Goparaju, Lakshmi; Gandhi, Monica; Merenstein, Dan
2009-01-01
Abstract To determine prevalence and predictors of complementary and alternative medicine (CAM) use disclosure to health care providers and whether CAM use disclosure is associated with highly active antiretroviral therapy (HAART) adherence among HIV-infected women, we analyzed longitudinal data collected between October 1994 and March 2002 from HIV-infected CAM-using women enrolled in the Women's Interagency HIV Study. Repeated measures Poisson regression models were constructed to evaluate associations of selected predictors with CAM use disclosure and association between CAM use disclosure and HAART adherence. A total of 1377 HIV-infected women reported CAM use during study follow-up and contributed a total of 4689 CAM-using person visits. The overall prevalence of CAM use disclosure to health care providers was 36% across study visits. Women over 45 years old, with a college education, or with health insurance coverage were more likely to disclose their CAM use to health care providers, whereas women identified as non-Hispanic Black or other ethnicities were less likely to communicate their CAM usage. More health care provider visits, more CAM domains used, and higher health care satisfaction scores had significant relationships with increased levels of CAM use disclosure. Restricting analysis to use of herbal or nonherbal medications only, similar results were obtained. Compared to other CAM domains, mind–body practice had the lowest prevalence of CAM use disclosure. Additionally, CAM use disclosure was significantly associated with higher HAART adherence. From this study, we showed that a high percentage of HIV-infected women did not discuss their CAM use with health care providers. Interventions targeted towards both physicians and patients may enhance communication of CAM use, avoid potential adverse events and drug interactions, and enhance HAART adherence. PMID:19821723
Complementary and alternative medicine use among paediatric emergency department patients.
Taylor, David McDonald; Dhir, Reetika; Craig, Simon S; Lammers, Thalia; Gardiner, Kaya; Hunter, Kirrily; Joffe, Paul; Krieser, David; Babl, Franz E
2015-09-01
To determine the period prevalence and nature of complementary and alternative medicine (CAM) use among paediatric emergency department (ED) patients and the perceptions of CAM among the CAM administrators. A survey was undertaken in four Victorian EDs (January to September 2013). A convenience sample of parents/carers accompanying paediatric patients completed a self-administered questionnaire. The main outcome measures were CAM use and perceptions of CAM. The parents/carers of 883 patients participated. Three hundred eighty-eight (43.9%, 95% confidence interval (CI) 40.6-47.3) and 53 (6.0%, 95% CI 4.6-7.8) patients had taken a CAM within the previous 12 months and on the day of presentation, respectively. There were no gender differences between CAM users and non-users (P = 0.83). The use of CAM was significantly more common among older patients (P < 0.001), those with European ethnicity (P = 0.046) and among those with chronic disease (P < 0.01). Fish oil, garlic, chamomile and acidophilus were the most commonly used CAM. Only 4.4% of CAM use was reported to the ED doctor. There were reports of potentially dangerous CAM use (St John's wort, ginseng). Parents/carers who had administered CAM were more likely to report that CAMs are safe, drug free and could prevent illness (P < 0.01). In addition, a number of this group reported that CAMs are more effective than prescription medicines and safe when taken with prescription medicines. CAM use is common among paediatric ED patients although rarely reported to the ED doctor. Parents/carers who administer CAM have differing perceptions of CAM safety from those who do not. © 2015 The Authors. Journal of Paediatrics and Child Health © 2015 Paediatrics and Child Health Division (Royal Australasian College of Physicians).
Classification of CAM use and its correlates in patients with early-stage breast cancer.
Saquib, Juliann; Madlensky, Lisa; Kealey, Sheila; Saquib, Nazmus; Natarajan, Loki; Newman, Vicky A; Patterson, Ruth E; Pierce, John P
2011-06-01
Self-reported use of complementary and alternative medicine (CAM) has been shown to increase following a cancer diagnosis, and breast cancer survivors are the heaviest users among cancer survivors. The aim of this study was to determine whether the prevalence estimate of CAM use varied according to classification of CAM. The authors used a comprehensive system to classify CAM users and test differences in demographic, lifestyle, quality of life, and cancer characteristics among them. Participants were 2562 breast cancer survivors participating in the Women's Healthy Eating and Living (WHEL) Study, aged 28 to 74 years. A structured telephone interview assessed CAM use, questioning about specific CAM practices, and whether use was related to cancer. This study examined CAM use in relation to demographics, health behaviors, and quality of life. Approximately 80% of the women used CAM for general purposes but only 50% reported CAM use for cancer purposes. Visual imagery, spiritual healing, and meditation were the most frequently used practices for cancer purposes. CAM use, defined as consulting a CAM practitioner and regular use, was significantly related to younger age, higher education, increased fruit and vegetable intake, and lower body mass index (P < .05). CAM users who had seen a practitioner were also more likely to report poor physical and mental health than non-CAM users (P < .05). CAM use was not associated with changes in physical and mental health between study baseline and 1-year follow-up. This study addressed important differences in the classification of CAM use among breast cancer survivors. Future studies need to further test the potential benefits and risks associated with CAM use.
The influence of polishing techniques on pre-polymerized CAD\\CAM acrylic resin denture bases
Alammari, Manal Rahma
2017-01-01
Background Lately, computer-aided design and computer-aided manufacturing (CAD/CAM) has broadly been successfully employed in dentistry. The CAD/CAM systems have recently become commercially available for fabrication of complete dentures, and are considered as an alternative technique to conventionally processed acrylic resin bases. However, they have not yet been fully investigated. Objective The purpose of this study was to inspect the effects of mechanical polishing and chemical polishing on the surface roughness (Ra) and contact angle (wettability) of heat-cured, auto-cured and CAD/CAM denture base acrylic resins. Methods This study was conducted at the Advanced Dental Research Laboratory Center of King Abdulaziz University from March to June 2017. Three denture base materials were selected: heat cure poly-methylmethacrylate resin, thermoplastic (polyamide resin) and (CAD\\CAM) denture base resin. Sixty specimens were prepared and divided into three groups, twenty in each. Each group was divided according to the polishing techniques into (Mech P) and (Chem P), ten specimens in each; surface roughness and wettability were investigated. Data were analyzed by SPSS version 22, using one-way ANOVA and Pearson coefficient. Results One-way analysis of variance (ANOVA) and post hoc tests were used for comparing the surface roughness values between three groups which revealed a statistical significant difference between them (p1<0.001). Heat-cured denture base material of (Group I) in both methods, showed the highest mean surface roughness value (2.44±0.07, 2.72±0.09, Mech P and Chem P respectively); while CAD\\CAM denture base material (group III) showed the least mean values (1.08±0.23, 1.39±0.31, Mech P and Chem P respectively). CAD/CAM showed the least contact angle in both polishing methods, which were statistically significant at 5% level (p=0.034 and p<0.001). Conclusion Mechanical polishing produced lower surface roughness of CAD\\CAM denture base resin with superior smooth surface compared to chemical polishing. Mechanical polishing is considered the best effective polishing technique. CAD/CAM denture base material should be considered as the material of choice for complete denture construction in the near future, especially for older dental patients with changed salivary functions, because of its wettability. PMID:29238483
The influence of polishing techniques on pre-polymerized CAD\\CAM acrylic resin denture bases.
Alammari, Manal Rahma
2017-10-01
Lately, computer-aided design and computer-aided manufacturing (CAD/CAM) has broadly been successfully employed in dentistry. The CAD/CAM systems have recently become commercially available for fabrication of complete dentures, and are considered as an alternative technique to conventionally processed acrylic resin bases. However, they have not yet been fully investigated. The purpose of this study was to inspect the effects of mechanical polishing and chemical polishing on the surface roughness (Ra) and contact angle (wettability) of heat-cured, auto-cured and CAD/CAM denture base acrylic resins. This study was conducted at the Advanced Dental Research Laboratory Center of King Abdulaziz University from March to June 2017. Three denture base materials were selected: heat cure poly-methylmethacrylate resin, thermoplastic (polyamide resin) and (CAD\\CAM) denture base resin. Sixty specimens were prepared and divided into three groups, twenty in each. Each group was divided according to the polishing techniques into (Mech P) and (Chem P), ten specimens in each; surface roughness and wettability were investigated. Data were analyzed by SPSS version 22, using one-way ANOVA and Pearson coefficient. One-way analysis of variance (ANOVA) and post hoc tests were used for comparing the surface roughness values between three groups which revealed a statistical significant difference between them (p 1 <0.001). Heat-cured denture base material of (Group I) in both methods, showed the highest mean surface roughness value (2.44±0.07, 2.72±0.09, Mech P and Chem P respectively); while CAD\\CAM denture base material (group III) showed the least mean values (1.08±0.23, 1.39±0.31, Mech P and Chem P respectively). CAD/CAM showed the least contact angle in both polishing methods, which were statistically significant at 5% level (p=0.034 and p<0.001). Mechanical polishing produced lower surface roughness of CAD\\CAM denture base resin with superior smooth surface compared to chemical polishing. Mechanical polishing is considered the best effective polishing technique. CAD/CAM denture base material should be considered as the material of choice for complete denture construction in the near future, especially for older dental patients with changed salivary functions, because of its wettability.
2011-01-01
Background Substantial recent research examines the efficacy of many types of complementary and alternative (CAM) therapies. However, outcomes associated with the "real-world" use of CAM has been largely overlooked, despite calls for CAM therapies to be studied in the manner in which they are practiced. Americans seek CAM treatments far more often for chronic musculoskeletal pain (CMP) than for any other condition. Among CAM treatments for CMP, acupuncture and chiropractic (A/C) care are among those with the highest acceptance by physician groups and the best evidence to support their use. Further, recent alarming increases in delivery of opioid treatment and surgical interventions for chronic pain--despite their high costs, potential adverse effects, and modest efficacy--suggests the need to evaluate real world outcomes associated with promising non-pharmacological/non-surgical CAM treatments for CMP, which are often well accepted by patients and increasingly used in the community. Methods/Design This multi-phase, mixed methods study will: (1) conduct a retrospective study using information from electronic medical records (EMRs) of a large HMO to identify unique clusters of patients with CMP (e.g., those with differing demographics, histories of pain condition, use of allopathic and CAM health services, and comorbidity profiles) that may be associated with different propensities for A/C utilization and/or differential outcomes associated with such care; (2) use qualitative interviews to explore allopathic providers' recommendations for A/C and patients' decisions to pursue and retain CAM care; and (3) prospectively evaluate health services/costs and broader clinical and functional outcomes associated with the receipt of A/C relative to carefully matched comparison participants receiving traditional CMP services. Sensitivity analyses will compare methods relying solely on EMR-derived data versus analyses supplementing EMR data with conventionally collected patient and clinician data. Discussion Successful completion of these aggregate aims will provide an evaluation of outcomes associated with the real-world use of A/C services. The trio of retrospective, qualitative, and prospective study will also provide a clearer understanding of the decision-making processes behind the use of A/C for CMP and a transportable methodology that can be applied to other health care settings, CAM treatments, and clinical populations. Trial registration ClinicalTrials.gov: NCT01345409 PMID:22118061
Use of complementary and alternative medicine before and after organ removal due to urologic cancer
Mani, Jens; Juengel, Eva; Arslan, Ilhan; Bartsch, Georg; Filmann, Natalie; Ackermann, Hanns; Nelson, Karen; Haferkamp, Axel; Engl, Tobias; Blaheta, Roman A
2015-01-01
Objective Many patients use complementary and alternative medicine (CAM) as primary treatment or symptom relief for a variety of illnesses. This study was designed to investigate the influence of surgical removal of a tumor-bearing urogenital organ on CAM use. Methods From 2007 to 2011, 350 patients underwent major urological surgery for kidney, prostate, or bladder cancer at the Goethe-University Hospital, Frankfurt, Germany. Data from 172 patients (49%), who returned a questionnaire, were retrospectively evaluated using the hospital information system along with the questionnaire to objectify CAM use 2 years before and after surgery. Results From the 172 patients returning questionnaires, 56 (33%) used CAM before and/or after surgery and 116 (67%) never used CAM. Of the 56 CAM users, 30 (54%) used CAM presurgery and 53 (95%) used CAM postsurgery, indicating a significant change of mind about CAM use. Patients of German nationality used CAM significantly more than patients of other nationalities. Higher educational status (high-school diploma or higher) was a significant factor in favor of CAM use. The most common type of CAM used before/after surgery was an alternative medical system (63/49%), a manipulative and body-based method (50/19%), and a biological-based therapy (37/32%). Information about CAM, either provided by medical professionals or by other sources, was the main reason determining whether patients used CAM or not. Conclusion The number of patients using CAM almost doubled after surgical removal of a cancer-bearing organ. Better awareness and understanding of CAM use by medical professionals could improve patient counseling. PMID:26491269
AlGhamdi, Khalid M; Khurrum, Huma; Asiri, Yousif
2017-09-01
Background / aim: Although complementary and alternative medicine (CAM) use is highly prevalent, there is very limited information on dermatologists' attitudes and knowledge about CAM. In this survey, we aimed to study the knowledge and attitude of dermatologists in Saudi Arabia towards CAM. Furthermore, we assessed dermatologists' intention to receive CAM education and training. Methods and design: We collected data through an online cross-sectional survey sent to email addresses of dermatologists in Saudi Arabia. Questions included socio-demographic data, knowledge and attitudes towards CAM practice. Results: A total of 93 questionnaires were returned from dermatologists in various regions of Saudi Arabia. The mean age was 41.7 ± 10.3 (range, 25-63) years. A total of 67% of dermatologists had welcoming attitudes towards CAM. We did not find any significant relationship between age, gender, experience or any other factor and positive attitudes towards CAM. More than 70% of participants reported an interest in learning about CAM. However, only 9 (9.7%) dermatologists had attended CAM courses. Sixty-one participants (65.6%) were eager to receive CAM-specific education, and 66% of dermatologists acknowledged having previously discussed CAM with their patients. The most important reason that dermatologists did not discuss CAM with their patients was a lack of studies supporting CAM (66.7%) and the belief that doctors' knowledge on CAM is insufficient (58.1%). Conclusion: A greater number of dermatologists have an affirmative attitude towards CAM. The willingness to improve knowledge and training indicates that the CAM field could potentially grow in dermatology.
The PALM-3000 high-order adaptive optics system for Palomar Observatory
NASA Astrophysics Data System (ADS)
Bouchez, Antonin H.; Dekany, Richard G.; Angione, John R.; Baranec, Christoph; Britton, Matthew C.; Bui, Khanh; Burruss, Rick S.; Cromer, John L.; Guiwits, Stephen R.; Henning, John R.; Hickey, Jeff; McKenna, Daniel L.; Moore, Anna M.; Roberts, Jennifer E.; Trinh, Thang Q.; Troy, Mitchell; Truong, Tuan N.; Velur, Viswa
2008-07-01
Deployed as a multi-user shared facility on the 5.1 meter Hale Telescope at Palomar Observatory, the PALM-3000 highorder upgrade to the successful Palomar Adaptive Optics System will deliver extreme AO correction in the near-infrared, and diffraction-limited images down to visible wavelengths, using both natural and sodium laser guide stars. Wavefront control will be provided by two deformable mirrors, a 3368 active actuator woofer and 349 active actuator tweeter, controlled at up to 3 kHz using an innovative wavefront processor based on a cluster of 17 graphics processing units. A Shack-Hartmann wavefront sensor with selectable pupil sampling will provide high-order wavefront sensing, while an infrared tip/tilt sensor and visible truth wavefront sensor will provide low-order LGS control. Four back-end instruments are planned at first light: the PHARO near-infrared camera/spectrograph, the SWIFT visible light integral field spectrograph, Project 1640, a near-infrared coronagraphic integral field spectrograph, and 888Cam, a high-resolution visible light imager.
Doering, Jan H; Reuner, Gitta; Kadish, Navah E; Pietz, Joachim; Schubert-Bast, Susanne
2013-10-01
Parents of pediatric patients with chronic conditions such as epilepsy increasingly opt for complementary and alternative medicine (CAM). However, data on the pattern and reasons of CAM use in childhood epilepsy are scarce. The objectives of this study were as follows: first, to characterize CAM use among pediatric patients with epilepsy by assessing its spectrum, prevalence, costs, and frequency of use; second, to evaluate the influence of CAM use on compliance and satisfaction with conventional care as well as to explore parent-child neurologist communication concerning CAM; and third, to investigate predictors of CAM use. A postal survey was administered to all parents of pediatric outpatients with epilepsy aged 6 to 12, who have received treatment at the neuropediatric outpatient clinic of the University Children's Hospital Heidelberg between 2007 and 2009. One hundred thirty-two of the 297 distributed questionnaires were suitable for inclusion in statistical analysis (44.7%). Forty-nine participants indicated that their children used CAM during the previous year (37.1%). Thirty different types of CAM were used, with homeopathy (55.1%), osteopathy (24.5%), and kinesiology (16.3%) being the most commonly named. A mean of 86€ (0€-500€) and 3h (1 h-30 h) per month was committed to CAM treatment. Only 53% of the users informed their child neurologist of the additional CAM treatment, while 85.6% of all parents wished to discuss CAM options with their child neurologist. Seventy-five percent of users considered the CAM treatment effective. Among the participants most likely to seek CAM treatment are parents whose children show a long duration of epileptic symptoms, parents who make use of CAM treatment themselves, and parents who value a holistic and natural treatment approach. A substantial portion of pediatric patients with epilepsy receive CAM treatment. The high prevalence of use and significant level of financial and time resources spent on CAM indicate the high importance of these treatment options for parents. On the other hand, communication concerning CAM with the child neurologist is largely insufficient despite the wish to speak about CAM. Complementary and alternative medicine users' high compliance with conventional treatment and high perceived effectiveness of CAM support an integrative approach to CAM for pediatric patients with epilepsy. Our study implies that in addition to open parent-child neurologist communication, active inquiry on CAM treatments is necessary to enable informed decision making by parents and to establish the suitability of CAM treatment for the patient. Reliable predictors for CAM use, which allow for improved identification of patients with a high likelihood to receive CAM treatment, are the duration of the illness, use of CAM by the parents themselves, and the desire of the parents to receive a holistic and natural treatment for their child. © 2013.
Geneva mechanism. [including star wheel and driver
NASA Technical Reports Server (NTRS)
Summers, R. H.; Kenney, R. L. (Inventor)
1974-01-01
An improved Geneva mechanism is characterized by a driven star-wheel having a segmented cam-follower surface. Star-wheel driver includes a restraining cam having a segmented cam surface for engaging the cam-follower surface of the star-wheel and antifriction rollers pinned to the restraining cam for engaging the cam-follower surface.
NASA Astrophysics Data System (ADS)
Konno, Norio; Katori, Makoto
The one-dimensional contact process (CP) is studied by a systematic series of approximations. A new decoupling procedure of correlation functions is proposed by combining the idea of Suzuki's correlation-identity-decoupling (CID) with a concept of window. Liggett's approximations are also considered. Applying Suzuki's coherent-anomaly method (CAM) to the mean-field-type solutions, the values of the critical point and the critical exponents are estimated as λc = 1.6490(±0.0008), β=0.280(±0.013), Δ(= Δ/δ)= 1.734(±O.OO1), β=0.627(±0.005). Finally a comparison with other estimates is shown.
NASA Astrophysics Data System (ADS)
Konno, Norio; Katori, Makoto
1990-05-01
The one-dimensional contact process (CP) is studied by a systematic series of approximations. A new decoupling procedure of correlation functions is proposed by combining the idea of Suzuki’s correlation-identity-decoupling (CID) with a concept of window. Liggett’s approximations are also considered. Applying Suzuki’s coherent-anomaly method (CAM) to the mean-field-type solutions, the values of the critical point and the critical exponents are estimated as λc{=}1.6490(± 0.0008), β{=}0.280(± 0.013), \\varDelta({=}β/δ){=}1.734(± 0.001), \\hatβ{=}0.627(± 0.005). Finally a comparison with other estimates is shown.
Herrera, Ana
2009-01-01
Background In obligate Crassulacean acid metabolism (CAM), up to 99 % of CO2 assimilation occurs during the night, therefore supporting the hypothesis that CAM is adaptive because it allows CO2 fixation during the part of the day with lower evaporative demand, making life in water-limited environments possible. By comparison, in facultative CAM (inducible CAM, C3-CAM) and CAM-cycling plants drought-induced dark CO2 fixation may only be, with few exceptions, a small proportion of C3 CO2 assimilation in watered plants and occur during a few days. From the viewpoint of survival the adaptive advantages, i.e. increased fitness, of facultative CAM and CAM-cycling are not obvious. Therefore, it is hypothesized that, if it is to increase fitness, CAM must aid in reproduction. Scope An examination of published reports of 23 facultative CAM and CAM-cycling species finds that, in 19 species, drought-induced dark CO2 fixation represents on average 11 % of C3 CO2 assimilation of watered plants. Evidence is discussed on the impact of the operation of CAM in facultative and CAM-cycling plants on their survival – carbon balance, water conservation, water absorption, photo-protection of the photosynthetic apparatus – and reproductive effort. It is concluded that in some species, but not all, facultative and cycling CAM contribute, rather than to increase carbon balance, to increase water-use efficiency, water absorption, prevention of photoinhibition and reproductive output. PMID:18708641
Herrera, Ana
2009-02-01
In obligate Crassulacean acid metabolism (CAM), up to 99 % of CO(2) assimilation occurs during the night, therefore supporting the hypothesis that CAM is adaptive because it allows CO(2) fixation during the part of the day with lower evaporative demand, making life in water-limited environments possible. By comparison, in facultative CAM (inducible CAM, C(3)-CAM) and CAM-cycling plants drought-induced dark CO(2) fixation may only be, with few exceptions, a small proportion of C(3) CO(2) assimilation in watered plants and occur during a few days. From the viewpoint of survival the adaptive advantages, i.e. increased fitness, of facultative CAM and CAM-cycling are not obvious. Therefore, it is hypothesized that, if it is to increase fitness, CAM must aid in reproduction. Scope An examination of published reports of 23 facultative CAM and CAM-cycling species finds that, in 19 species, drought-induced dark CO(2) fixation represents on average 11 % of C(3) CO(2) assimilation of watered plants. Evidence is discussed on the impact of the operation of CAM in facultative and CAM-cycling plants on their survival--carbon balance, water conservation, water absorption, photo-protection of the photosynthetic apparatus--and reproductive effort. It is concluded that in some species, but not all, facultative and cycling CAM contribute, rather than to increase carbon balance, to increase water-use efficiency, water absorption, prevention of photoinhibition and reproductive output.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moran, Meena S., E-mail: meena.moran@yale.edu; Department of Radiation Therapy, William W. Backus Hospital, Norwich, Connecticut; Ma Shuangge
Purpose: Although complementary and alternative medicine (CAM) utilization in breast cancer patients is reported to be high, there are few data on CAM practices in breast patients specifically during radiation. This prospective, multi-institutional study was conducted to define CAM utilization in breast cancer during definitive radiation. Materials/Methods: A validated CAM instrument with a self-skin assessment was administered to 360 Stage 0-III breast cancer patients from 5 centers during the last week of radiation. All data were analyzed to detect significant differences between users/nonusers. Results: CAM usage was reported in 54% of the study cohort (n=194/360). Of CAM users, 71% reportedmore » activity-based CAM (eg, Reiki, meditation), 26% topical CAM, and 45% oral CAM. Only 16% received advice/counseling from naturopathic/homeopathic/medical professionals before initiating CAM. CAM use significantly correlated with higher education level (P<.001), inversely correlated with concomitant hormone/radiation therapy use (P=.010), with a trend toward greater use in younger patients (P=.066). On multivariate analysis, level of education (OR: 6.821, 95% CI: 2.307-20.168, P<.001) and hormones/radiation therapy (OR: 0.573, 95% CI: 0.347-0.949, P=.031) independently predicted for CAM use. Significantly lower skin toxicity scores were reported in CAM users vs nonusers, respectively (mild: 34% vs 25%, severe: 17% vs 29%, P=.017). Conclusion: This is the first prospective study to assess CAM practices in breast patients during radiation, with definition of these practices as the first step for future investigation of CAM/radiation interactions. These results should alert radiation oncologists that a large percentage of breast cancer patients use CAM during radiation without disclosure or consideration for potential interactions, and should encourage increased awareness, communication, and documentation of CAM practices in patients undergoing radiation treatment for breast cancer.« less
Hundred lightcurves of sub-km main-belt asteroids
NASA Astrophysics Data System (ADS)
Yoshida, F.; Souami, D.; Bouquillon, S.; Nakamura, T.; Dermawan, B.; Yagi, M.; Souchay, J.
2014-07-01
We observed a single sky field near opposition and near the ecliptic plane using the Subaru telescope equipped with the Suprime-Cam. Taking advantage of the wide field of view (FOV) for the Suprime-Cam, the plan was to obtain 100 lightcurves of asteroids at the same time. The total observing time interval was about 8 hours on September 2, 2002, with 2-min exposures. We detected 147 moving objects in the single FOV (34'×27') on the Suprime-Cam (see Figure). Of those, 112 detections corresponded to different objects. We used the R filter during almost the entire observing run, but we took a few images with the B filter at the beginning, the middle, and the end of the run. We classified main-belt asteroids into S- and C-complexes with the B-R color of the object (Yoshida & Nakamura 2007). Although we carefully avoided regions of bright stars, the sky in the images taken by Suprime-Cam were actually crowded with faint objects. Therefore, the asteroids overlapped with background stars very often. Thus, it was very difficult to get lightcurves with high accuracy. We modified the GAIA-GBOT (Ground Based Optical Tracking) PIPELINE to measure the position and brightness of each object (Bouquillon et al. 2012). Once the objects were identified and their positions measured in pixel coordinates, the pipeline proceeded to the astrometric calibration and then to the photometric calibrations with the Guide Star Catalog II (Lasker et al. 2008). The pipeline produced time series of photometry for each object. The average brightness of each lightcurve ranged between 19--24 mag. We then estimated the rotational period from the lightcurve of each object. In our presentation, we will show the spin-period distribution of sub- km main-belt asteroids and compare it with that of large main-belt asteroids obtained from the lightcurve catalogue.
Mehl-Madrona, Lewis; Mainguy, Barbara; Plummer, Julie
2016-08-01
Opiates are no longer considered the best strategy for the long-term management of chronic pain. Yet, physicians have made many patients dependent on them, and these patients still request treatment. Complementary and alternative medicine (CAM) therapies have been shown to be effective, but are not widely available and are not often covered by insurance or available to the medically underserved. Group medical visits (GMVs) provided education about non-pharmacological methods for pain management and taught mindfulness techniques, movement, guided imagery, relaxation training, yoga, qigong, and t'ai chi. Forty-two patients attending GMVs for at least six months were matched prospectively with patients receiving conventional care. No one increased their dose of opiates. Seventeen people reduced their dose, and seven people stopped opiates. On a 10-point scale of pain intensity, reductions in pain ratings achieved statistical significance (p = 0.001). The average reduction was 0.19 (95% confidence interval [CI] 0.12-0.60; p = 0.01). The primary symptom improved on average by -0.42 (95% CI -0.31 to -0.93; p = 0.02) on the My Medical Outcome Profile, 2nd version. Improvement in the quality-of-life rating was statistically significant (p = 0.007) with a change of -1.42 (95% CI = -0.59 to -1.62). In conventional care, no patients reduced their opiate use, and 48.5% increased their dose over the two years of the project. GMVs that incorporated CAM therapies helped patients reduce opiate use. While some patients found other physicians to give them the opiates they desired, those who persisted in an environment of respect and acceptance significantly reduced opiate consumption compared with patients in conventional care. While resistant to CAM therapies initially, the majority of patients came to accept and to appreciate their usefulness. GMVs were useful for incorporating non-reimbursed CAM therapies into primary medical care.
Iyer, Rajiv R; Wu, Adela; Macmillan, Alexandra; Musavi, Leila; Cho, Regina; Lopez, Joseph; Jallo, George I; Dorafshar, Amir H; Ahn, Edward S
2018-01-01
Cranial vault remodeling surgery for craniosynostosis carries the potential risk of dural venous sinus injury given the extensive bony exposure. Identification of the dural venous sinuses can be challenging in patients with craniosynostosis given the lack of accurate surface-localizing landmarks. Computer-aided design and manufacturing (CAD/CAM) has allowed surgeons to pre-operatively plan these complex procedures in an effort to increase reconstructive efficiency. An added benefit of this technology is the ability to intraoperatively map the dural venous sinuses based on pre-operative imaging. We utilized CAD/CAM technology to intraoperatively map the dural venous sinuses for patients undergoing reconstructive surgery for craniosynostosis in an effort to prevent sinus injury, increase operative efficiency, and enhance patient safety. Here, we describe our experience utilizing this intraoperative technology in pediatric patients with craniosynostosis. We retrospectively reviewed the charts of children undergoing reconstructive surgery for craniosynostosis using CAD/CAM surgical planning guides at our institution between 2012 and 2016. Data collected included the following: age, gender, type of craniosynostosis, estimated blood loss, sagittal sinus deviation from the sagittal suture, peri-operative outcomes, and hospital length of stay. Thirty-two patients underwent reconstructive cranial surgery for craniosynostosis, with a median age of 11 months (range, 7-160). Types of synostosis included metopic (6), unicoronal (6), sagittal (15), lambdoid (1), and multiple suture (4). Sagittal sinus deviation from the sagittal suture was maximal in unicoronal synostosis patients (10.2 ± 0.9 mm). All patients tolerated surgery well, and there were no occurrences of sagittal sinus, transverse sinus, or torcular injury. The use of CAD/CAM technology allows for accurate intraoperative dural venous sinus localization during reconstructive surgery for craniosynostosis and enhances operative efficiency and surgeon confidence while minimizing the risk of patient morbidity.
Chui, Ping Lei; Abdullah, Khatijah Lim; Wong, Li Ping; Taib, Nur Aishah
2015-01-01
Background Complementary and alternative medicine (CAM) use has become increasingly popular among patients with cancer. The purposes of this study were to compare the QOL in CAM users and non-CAM users and to determine whether CAM use influences QOL among breast cancer patients during chemotherapy. Methodology A cross-sectional survey was conducted at two outpatient chemotherapy centers. A total of 546 patients completed the questionnaires on CAM use. QOL was evaluated based on the European Organization for Research and Treatment of Cancer (EORTC) core quality of life (QLQ-C30) and breast cancer-specific quality of life (QLQ-BR23) questionnaires. Results A total of 70.7% of patients were identified as CAM users. There was no significant difference in global health status scores and in all five subscales of the QLQ C30 functional scales between CAM users and non-CAM users. On the QLQ-C30 symptom scales, CAM users (44.96±3.89) had significantly (p = 0.01) higher mean scores for financial difficulties than non-CAM users (36.29±4.81). On the QLQ-BR23 functional scales, CAM users reported significantly higher mean scores for sexual enjoyment (6.01±12.84 vs. 4.64±12.76, p = 0.04) than non-CAM users. On the QLQ-BR23 symptom scales, CAM users reported higher systemic therapy side effects (41.34±2.01 vs. 37.22±2.48, p = 0.04) and breast symptoms (15.76±2.13 vs. 11.08±2.62, p = 0.02) than non-CAM users. Multivariate logistic regression analysis indicated that the use of CAM modality was not significantly associated with higher global health status scores (p = 0.71). Conclusion While the findings indicated that there was no significant difference between users and non-users of CAM in terms of QOL, CAM may be used by health professionals as a surrogate to monitor patients with higher systemic therapy side effects and breast symptoms. Furthermore, given that CAM users reported higher financial burdens (which may have contributed to increased distress), patients should be encouraged to discuss the potential benefits and/or disadvantages of using CAM with their healthcare providers. PMID:26451732
Chui, Ping Lei; Abdullah, Khatijah Lim; Wong, Li Ping; Taib, Nur Aishah
2014-10-30
The inclusion of prayer-for-health (PFH) in the definition of complementary alternative medicine (CAM) has resulted in higher levels of CAM use. The objective of this study was to assess PFH and CAM use among breast cancer patients undergoing chemotherapy. A cross-sectional study was performed at two chemotherapy providers. Patients were questioned about use of three categories of CAM, mind-body practices (MBPs), natural products (NPs) and traditional medicine (TM). PFH was also examined separately from CAM to better characterise the patterns of CAM and PFH used during chemotherapy. A total of 546 eligible patients participated in the study; 70.7% (n = 386) reported using some form of CAM, and 29.3% (n = 160) were non-CAM users. When PFH was excluded as a CAM, fewer patients reported the use of CAM (66.1%; n = 361). The total number of patients who used MBPs decreased from 342 to 183. The most common CAM use category was NPs (82.8%), followed by MBPs (50.7%), and TM (35.7%). CAM users were more likely to have a tertiary education (OR 2.11, 95% CI 1.15-3.89 vs. primary/lower), have household incomes > RM 3,000 (≈944 USD) per month (OR 2.32, 95% CI 1.40-3.84 vs. ≤RM 3,000 (≈944 USD)), and have advanced cancer (OR 1.75, 95% CI 1.18-2.59 vs. early stage cancer), compared with non-CAM users. The CAM users were less likely to have their chemotherapy on schedule (OR 0.24, 95% CI 0.10-0.58 vs. chemotherapy postponed) than non-CAM users. Most MBPs were perceived to be more helpful by their users, compared with the users of NPs and TM. CAM use was prevalent among breast cancer patients. Excluding PFH from the definition of CAM reduced the prevalence of overall CAM use. Overall, CAM use was associated with higher education levels and household incomes, advanced cancer and lower chemotherapy schedule compliance. Many patients perceived MBP to be beneficial for improving overall well-being during chemotherapy. These findings, while preliminary, clearly indicate the differences in CAM use when PFH is included in, and excluded from, the definition of CAM.
Thermodynamic Effects of Noncoded and Coded Methionine Substitutions in Calmodulin
Yamniuk, Aaron P.; Ishida, Hiroaki; Lippert, Dustin; Vogel, Hans J.
2009-01-01
The methionine residues in the calcium (Ca2+) regulatory protein calmodulin (CaM) are structurally and functionally important. They are buried within the N- and C-domains of apo-CaM but become solvent-exposed in Ca2+-CaM, where they interact with numerous target proteins. Previous structural studies have shown that methionine substitutions to the noncoded amino acids selenomethionine, ethionine, or norleucine, or mutation to leucine do not impact the main chain structure of CaM. Here we used differential scanning calorimetry to show that these substitutions enhance the stability of both domains, with the largest increase in melting temperature (19–26°C) achieved with leucine or norleucine in the apo-C-domain. Nuclear magnetic resonance spectroscopy experiments also revealed the loss of a slow conformational exchange process in the Leu-substituted apo-C-domain. In addition, isothermal titration calorimetry experiments revealed considerable changes in the enthalpy and entropy of target binding to apo-CaM and Ca2+-CaM, but the free energy of binding was largely unaffected due to enthalpy-entropy compensation. Collectively, these results demonstrate that noncoded and coded methionine substitutions can be accommodated in CaM because of the structural plasticity of the protein. However, adjustments in side-chain packing and dynamics lead to significant differences in protein stability and the thermodynamics of target binding. PMID:19217866
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hadlock, D.J.
Historically, the Savannah River Site, like many Department of Energy sites, has used some multiple of the expected Derived Air Concentration (DAC) of a radionuclide as a suspension guide for Radiological Work Permits (RWP) or validation of selected respiratory protection equipment. The term DAC expresses the concentration of a radionuclide in air, typically in mCi/cc. Even though the term DAC is derived from an intake of radioactivity (Annual Limit on Intake) that would result in defined estimated dose to a worker, knowing only the DAC value does not allow a worker's potential dose to be determined. Recently, the Savannah Rivemore » Site has converted to the use of DAC-hours for RWP suspension guides and respiratory equipment validation. The term DAC-hr takes into account not only the concentration of the radionuclide in air (DAC) but also the time the individual was exposed allowing an estimate of a worker's dose to be determined. The conversion to DAC-hrs resulted in four benefits to the radiation protection program without increasing the risk to workers; (1) consistency with the constant air monitor (CAM) alarm setpoint protocol; (2) consistency with Internal Dosimetry terminology; (3) an a priori determination of the potential risk to a worker; and (4) reduced complexity/error in field calculations. This paper outlines the justification for the conversion to DAC-hrs, the protocols used for field and count room calculations, and the implementation process utilized at the Savannah River Site« less
Elder, William G.; Purdy, Hunter; Bentley, Andrew
2009-01-01
To prepare allopathic providers to advise patients about complementary and alternative medicine (CAM) therapies, the University of Kentucky CAM curriculum integration project has identified and trained CAM practitioners to coteach, precept, and demonstrate their respective practices. This project is interested in integrating CAM practitioners as teachers into this university and has formed a multidisciplinary committee for advice. The committee has recognized the importance of increased understanding of CAM practices to enhance communication within itself and to decide to which CAM practices students should receive exposure. This article reports our attempt to create a CAM practice description, based on questions general to CAM practice and specific to a particular approach. Because there is limited existing systematic research on CAM practice characteristics, these questions may interest researchers conducting qualitative studies, especially those seeking an example of questions to ask CAM practitioners. We also believe this practice description will be of general interest. PMID:19890441
Merenstein, Daniel; Yang, Yang; Schneider, Michael F; Goparaju, Lakshmi; Weber, Kathleen; Sharma, Anjali; Levine, Alexandra M; Sharp, Gerald B; Gandhi, Monica; Liu, Chenglong
2008-01-01
To assess whether complementary and alternative medicine (CAM) use is associated with the timing of highly active antiretroviral therapy (HAART) initiation among human immunodeficiency virus (HIV)-infected participants of the Women's Interagency HIV Study. Prospective cohort study between January 1996 and March 2002. Differences in the cumulative incidence of HAART initiation were compared between CAM users and non-CAM users using a logrank test. Cox regression model was used to assess associations of CAM exposures with time to HAART initiation. MAIN OUTCOME AND EXPOSURES: Study outcome was time from January 1996 to initiation of HAART. Primary exposure was use of any CAM modality before January 1996, and secondary exposures included the number and type of CAM modalities used (ingestible CAM medication, body practice, or spiritual healing) during the same period. One thousand thirty-four HIV-infected women contributed a total of 4987 person-visits during follow-up. At any time point, the cumulative incidence of HAART initiation among CAM users was higher than that among non-CAM users. After adjustment for potential confounders, those reporting CAM use were 1.34 times (95% confidence interval: 1.09, 1.64) more likely to initiate HAART than non-CAM users. Female CAM users initiated HAART regimens earlier than non-CAM users. Initiation of HAART is an important clinical marker, but more research is needed to elucidate the role specific CAM modalities play in HIV disease progression.
Chao, Maria T.; Wade, Christine; Kronenberg, Fredi
2009-01-01
Background Complementary and alternative medicine (CAM) is often used alongside conventional medical care, yet fewer than half of patients disclose CAM use to medical doctors. CAM disclosure is particularly low among racial/ethnic minorities, but reasons for differences, such as type of CAM used or quality of conventional healthcare, have not been explored. Objective We tested the hypotheses that disclosure of CAM use to medical doctors is higher for provider-based CAM and among non-Hispanic whites, and that access to and quality of conventional medical care account for racial/ethnic differences in CAM disclosure. Methods Bivariate and multiple variable analyses of the 2002 National Health Interview Survey and 2001 Health Care Quality Survey were performed. Results Disclosure of CAM use to medical providers was higher for provider-based than self-care CAM. Disclosure of any CAM was associated with access to and quality of conventional care and higher among non-Latino whites relative to minorities. Having a regular doctor and quality patient–provider relationship mitigated racial/ethnic differences in CAM disclosure. Conclusion Insufficient disclosure of CAM use to conventional providers, particularly for self-care practices and among minority populations, represents a serious challenge in medical encounter communications. Efforts to improve disclosure of CAM use should be aimed at improving consistency of care and patient–physician communication across racial/ethnic groups. PMID:19024232
Consequences of systematic model drift in DYNAMO MJO hindcasts with SP-CAM and CAM5
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hannah, Walter M.; Maloney, Eric D.; Pritchard, Michael S.
Hindcast simulations of MJO events during the dynamics of the MJO (DYNAMO) field campaign are conducted with two models, one with conventional parameterization (CAM5) and a comparable model that utilizes superparameterization (SP–CAM). SP–CAM is shown to produce a qualitatively better reproduction of the fluctuations of precipitation and low–level zonal wind associated with the first two DYNAMO MJO events compared to CAM5. Interestingly, skill metrics using the real–time multivariate MJO index (RMM) suggest the opposite conclusion that CAM5 has more skill than SP–CAM. This inconsistency can be explained by a systematic increase of RMM amplitude with lead time, which results frommore » a drift of the large–scale wind field in SP–CAM that projects strongly onto the RMM index. CAM5 hindcasts exhibit a contraction of the moisture distribution, in which extreme wet and dry conditions become less frequent with lead time. SP–CAM hindcasts better reproduce the observed moisture distribution, but also have stronger drift patterns of moisture budget terms, such as an increase in drying by meridional advection in SP–CAM. This advection tendency in SP–CAM appears to be associated with enhanced off–equatorial synoptic eddy activity with lead time. In conclusion, systematic drift moisture tendencies in SP–CAM are of similar magnitude to intraseasonal moisture tendencies, and therefore are important for understanding MJO prediction skill.« less
Computer-Based Technologies in Dentistry: Types and Applications
Albuha Al-Mussawi, Raja’a M.; Farid, Farzaneh
2016-01-01
During dental education, dental students learn how to examine patients, make diagnosis, plan treatment and perform dental procedures perfectly and efficiently. However, progresses in computer-based technologies including virtual reality (VR) simulators, augmented reality (AR) and computer aided design/computer aided manufacturing (CAD/CAM) systems have resulted in new modalities for instruction and practice of dentistry. Virtual reality dental simulators enable repeated, objective and assessable practice in various controlled situations. Superimposition of three-dimensional (3D) virtual images on actual images in AR allows surgeons to simultaneously visualize the surgical site and superimpose informative 3D images of invisible regions on the surgical site to serve as a guide. The use of CAD/CAM systems for designing and manufacturing of dental appliances and prostheses has been well established. This article reviews computer-based technologies, their application in dentistry and their potentials and limitations in promoting dental education, training and practice. Practitioners will be able to choose from a broader spectrum of options in their field of practice by becoming familiar with new modalities of training and practice. PMID:28392819
Computer-Based Technologies in Dentistry: Types and Applications.
Albuha Al-Mussawi, Raja'a M; Farid, Farzaneh
2016-06-01
During dental education, dental students learn how to examine patients, make diagnosis, plan treatment and perform dental procedures perfectly and efficiently. However, progresses in computer-based technologies including virtual reality (VR) simulators, augmented reality (AR) and computer aided design/computer aided manufacturing (CAD/CAM) systems have resulted in new modalities for instruction and practice of dentistry. Virtual reality dental simulators enable repeated, objective and assessable practice in various controlled situations. Superimposition of three-dimensional (3D) virtual images on actual images in AR allows surgeons to simultaneously visualize the surgical site and superimpose informative 3D images of invisible regions on the surgical site to serve as a guide. The use of CAD/CAM systems for designing and manufacturing of dental appliances and prostheses has been well established. This article reviews computer-based technologies, their application in dentistry and their potentials and limitations in promoting dental education, training and practice. Practitioners will be able to choose from a broader spectrum of options in their field of practice by becoming familiar with new modalities of training and practice.
Complementary alternative medicine for children with autism: a physician survey.
Golnik, Allison E; Ireland, Marjorie
2009-07-01
Previous studies suggest over half of children with autism are using complementary alternative medicine (CAM). In this study, physicians responded (n = 539, 19% response rate) to a survey regarding CAM use in children with autism. Physicians encouraged multi-vitamins (49%), essential fatty acids (25%), melatonin (25%) and probiotics (19%) and discouraged withholding immunizations (76%), chelation (61%), anti-infectives (57%), delaying immunizations (55%) and secretin (43%). Physicians encouraging CAM were more likely to desire CAM training, inquire about CAM use, be female, be younger, and report greater autism visits, autism education and CAM knowledge. Physicians were more likely to desire CAM training, inquire about CAM and view CAM as a challenge for children with autism compared to children with other neurodevelopmental and chronic/complex conditions.
Xu, Xiaojuan; Yano, Masafumi; Uchinoumi, Hitoshi; Hino, Akihiro; Suetomi, Takeshi; Ono, Makoto; Tateishi, Hiroki; Oda, Tetsuro; Okuda, Shinichi; Doi, Masahiro; Kobayashi, Shigeki; Yamamoto, Takeshi; Ikeda, Yasuhiro; Ikemoto, Noriaki; Matsuzaki, Masunori
2010-01-01
Calmodulin (CaM), one of the accessory proteins of the cardiac ryanodine receptor (RyR2), is known to play a significant role in the channel regulation of the RyR2. However, the possible involvement of calmodulin in the pathogenic process of catecholaminergic polymorphic ventricular tachycardia (CPVT) has not been investigated. In this study, we investigated the state of RyR2-bound CaM and channel dysfunctions using a knock-in (KI) mouse model with CPVT-linked RyR2 mutation (R2474S). Without added effectors, the affinity of CaM binding to the RyR2 was indistinguishable between KI and WT hearts. In response to cAMP (1 μmol/L), the RyR2 phosphorylation at Ser2808 increased in both WT and KI hearts to the same extent. However, cAMP caused a significant decrease of the CaM binding affinity in KI hearts, but the affinity was unchanged in WT. Dantrolene restored a normal level of CaM-binding affinity in the cAMP-treated KI hearts, suggesting that defective inter-domain interaction between the N-terminal domain and the central domain of the RyR2 (the target of therapeutic effect of dantrolene) is involved in the cAMP-induced reduction of the CaM binding affinity. In saponin-permeabilized cardiomyocytes, the addition of cAMP increased the frequency of spontaneous Ca2+ sparks to a significantly larger extent in KI cardiomyocytes than in WT cardiomyocytes, whereas the addition of a high concentration of CaM attenuated the aberrant increase of Ca2+ sparks. In conclusion, CPVT mutation causes defective inter-domain interaction, significant reduction in the ability of CaM binding to the RyR2, spontaneous Ca2+ leak, and then lethal arrhythmia. PMID:20226167
The Chick Embryo Chorioallantoic Membrane as an In Vivo Assay to Study Antiangiogenesis
Ribatti, Domenico
2010-01-01
Antiangiogenesis, e.g., inhibition of blood vessel growth, is being investigated as a way to prevent the growth of tumors and other angiogenesis-dependent diseases. Pharmacological inhibition interferes with the angiogenic cascade or the immature neovasculature with synthetic or semi-synthetic substances, endogenous inhibitors or biological antagonists. The chick embryo chorioallantoic membrane (CAM) is an extraembryonic membrane, which serves as a gas exchange surface and its function is supported by a dense capillary network. Because its extensive vascularization and easy accessibility, CAM has been used to study morphofunctional aspects of the angiogenesis process in vivo and to study the efficacy and mechanism of action of pro- and anti-angiogenic molecules. The fields of application of CAM in the study of antiangiogenesis, including our personal experience, are illustrated in this review article. PMID:27713265
Abnormal placental development and early embryonic lethality in EpCAM-null mice.
Nagao, Keisuke; Zhu, Jianjian; Heneghan, Mallorie B; Hanson, Jeffrey C; Morasso, Maria I; Tessarollo, Lino; Mackem, Susan; Udey, Mark C
2009-12-31
EpCAM (CD326) is encoded by the tacstd1 gene and expressed by a variety of normal and malignant epithelial cells and some leukocytes. Results of previous in vitro experiments suggested that EpCAM is an intercellular adhesion molecule. EpCAM has been extensively studied as a potential tumor marker and immunotherapy target, and more recent studies suggest that EpCAM expression may be characteristic of cancer stem cells. To gain insights into EpCAM function in vivo, we generated EpCAM -/- mice utilizing an embryonic stem cell line with a tacstd1 allele that had been disrupted. Gene trapping resulted in a protein comprised of the N-terminus of EpCAM encoded by 2 exons of the tacstd1 gene fused in frame to betageo. EpCAM +/- mice were viable and fertile and exhibited no obvious abnormalities. Examination of EpCAM +/- embryos revealed that betageo was expressed in several epithelial structures including developing ears (otocysts), eyes, branchial arches, gut, apical ectodermal ridges, lungs, pancreas, hair follicles and others. All EpCAM -/- mice died in utero by E12.5, and were small, developmentally delayed, and displayed prominent placental abnormalities. In developing placentas, EpCAM was expressed throughout the labyrinthine layer and by spongiotrophoblasts as well. Placentas of EpCAM -/- embryos were compact, with thin labyrinthine layers lacking prominent vascularity. Parietal trophoblast giant cells were also dramatically reduced in EpCAM -/- placentas. EpCAM was required for differentiation or survival of parietal trophoblast giant cells, normal development of the placental labyrinth and establishment of a competent maternal-fetal circulation. The findings in EpCAM-reporter mice suggest involvement of this molecule in development of vital organs including the gut, kidneys, pancreas, lungs, eyes, and limbs.
Wong, V C N
2009-03-01
A cross-sectional survey of the use of CAM by children was undertaken in the Duchess of Kent Children's Hospital in Hong Kong (March-December 2006). A questionnaire survey concerning the use of CAM was administered to chief caretakers (only the mothers) who accompanied children with neurodevelopmental disabilities followed up in our Neurodevelopmental paediatrics clinics. Four hundred and thirty agreed for interview of which 98 (22.8%) had Autism Spectrum Disorder (ASD). CAM was used in 40.8% for ASD and 21.4% of non-ASD (p < 0.001). We describe the profile of use of CAM in ASD in this part A paper. The three most common type of CAM use was Acupuncture (47.5%), Sensory Integration (42.5%), and Chinese Medicine (30%). About 76.9% of interviewees expected CAM to augment conventional treatment. Although 47.5% used both conventional western medicine and CAM, only 22.4% disclosed the use of CAM to Doctors. The following factors were significantly related to CAM use: father's job and mother's religion. Our frequency of CAM used in children with ASD was lower in Canada (52%) and USA (74%, 92%). The main CAM use in western culture was biological-based therapy whereas acupuncture was the most common CAM used in our locality.
Integrating CAM into nursing curricula: CAM camp as an educational intervention.
Cornman, B Jane; Carr, Catherine A; Heitkemper, Margaret M
2006-05-01
In 2002, the University of Washington School of Nursing (SON) partnered with Bastyr University on a five-year plan to offer a four-week intensive "CAM Camp" (CAMp) for SON faculty members and medical students from across the country. The four-week educational program introduced attendees to various complementary and alternative medicine (CAM) modalities through didactic and experiential learning. To enhance complementary and alternative medicine content in a SON curriculum and to increase SON faculty knowledge and understanding about (1) the range of CAM therapies, (2) the theoretic and cultural backgrounds of these therapies, and (3) their potential contributions to the health of diverse populations. A descriptive pretest, posttest design was used to compare pre-CAMp CAM knowledge and CAM course content with post-CAMp knowledge levels of faculty and course CAM content. On post-CAMp surveys, familiarity with CAM modalities was rated with mixed results as compared with positive reports on the qualitative interviews. Interview results were more positive about CAM in general and were less specific about individual CAM topics. Statistically significant increases in competences were evident in each of 13 competencies rated with four competencies at P < .01. The number of required and elective courses containing CAM content increased as did the CAM content in continuing education conferences offered by the SON.
Valve actuator for internal combustion engine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Uchida, T.
1987-06-16
A valve actuating mechanism is described for an overhead valve and overhead cam type internal combustion engine in which the camshaft is positioned above and between the valve and a cam follower seat member in a cylinder head of the engine. The cam follower seat member is threadedly mounted in the cylinder head and has a semi-spherical recess facing upwardly. A cam follower has an adjustable bolt threadedly received in one end of the cam follower. The adjustable bolt has a spherical fulcrum engaging the semispherical recess of the seat member. The cam follower also has a downwardly facing meansmore » on the other end for engaging the valve and an upwardly facing slipper face for sliding engagement with a cam on the camshaft. The cam is adapted to rotate across the slipper face in the direction of the valve. The slipper face has a surface shape for engaging the cam at the start of valve-lifting movement of the cam follower at a point through which a line tangent to the slipper face is substantially parallel to a line through contact points between the cam follower. The seat member and valve for minimizing the lateral forces are imposed on the cam follower by the cam at the start of the valve-lifting movement.« less
Liem, Andrian; Newcombe, Peter A; Pohlman, Annie
2017-08-01
This study aimed to evaluate questionnaire development to measure the knowledge of Complementary-Alternative Medicine (CAM), attitudes towards CAM, CAM experiences, and CAM educational needs of clinical psychologists in Indonesia. A 26-item questionnaire was developed through an extensive literature search. Data was obtained from provisional psychologists from the Master of Professional Clinical Psychology programs at two established public universities in urban areas of Indonesia. To validate the questionnaire, panel reviews by executive members of the Indonesian Clinical Psychology Association (ICPA), experts in health psychology, and experts in public health and CAM provided their professional judgements. The self-reporting questionnaire consisted of four scales including: knowledge of CAM (6 items), attitudes towards CAM (10 items), CAM experiences (4 items), and CAM educational needs (6 items). All scales, except CAM Experiences, were assessed on a 7-point Likert scale. Sixty provisional psychologists were eligible to complete the questionnaire with a response rate of 73% (N=44). The results showed that the CAM questionnaire was reliable (Cronbach's coefficient alpha range=0.62-0.96; item-total correlation range=0.14-0.92) and demonstrated content validity. Following further psychometric evaluation, the CAM questionnaire may provide the evidence-based information to inform the education and practice of Indonesian clinical psychologists. Copyright © 2017 Elsevier Ltd. All rights reserved.
Attitudes towards complementary and alternative medicine among medical and psychology students.
Ditte, Darja; Schulz, Wolfgang; Ernst, Gundula; Schmid-Ott, Gerhard
2011-03-01
The use of complementary and alternative medicine (CAM) is increasing in Europe as well as in the USA, but CAM courses are infrequently integrated into medical curricula. In Europe, but also especially in the USA and in Canada, the attitudes of medical students and health science professionals in various disciplines towards CAM have been the subject of investigation. Most studies report positive attitudes. The main aim of this study was to compare the attitudes towards CAM of medical and psychology students in Germany. An additional set of questions concerned how CAM utilisation and emotional and physical condition affect CAM-related attitudes. Two hundred thirty-three medical students and 55 psychology students were questioned concerning their attitudes towards CAM using the Questionnaire on Attitudes Towards Complementary Medical Treatment (QACAM). Both medical students and psychology students were sceptical about the diagnostic and the therapeutic proficiency of doctors and practitioners of CAM. Students' attitudes towards CAM correlated neither with their experiences as CAM patients nor with their emotional and physical condition. It can be assumed that German medical and psychology students will be reluctant to use or recommend CAM in their professional careers. Further studies should examine more closely the correlation between attitudes towards CAM and the students' worldview as well as their existing knowledge of the effectiveness of CAM.
Active-Site Hydration and Water Diffusion in Cytochrome P450cam: A Highly Dynamic Process
Miao, Yinglong; Baudry, Jerome
2011-01-01
Long-timescale molecular dynamics simulations (300 ns) are performed on both the apo- (i.e., camphor-free) and camphor-bound cytochrome P450cam (CYP101). Water diffusion into and out of the protein active site is observed without biased sampling methods. During the course of the molecular dynamics simulation, an average of 6.4 water molecules is observed in the camphor-binding site of the apo form, compared to zero water molecules in the binding site of the substrate-bound form, in agreement with the number of water molecules observed in crystal structures of the same species. However, as many as 12 water molecules can be present at a given time in the camphor-binding region of the active site in the case of apo-P450cam, revealing a highly dynamic process for hydration of the protein active site, with water molecules exchanging rapidly with the bulk solvent. Water molecules are also found to exchange locations frequently inside the active site, preferentially clustering in regions surrounding the water molecules observed in the crystal structure. Potential-of-mean-force calculations identify thermodynamically favored trans-protein pathways for the diffusion of water molecules between the protein active site and the bulk solvent. Binding of camphor in the active site modifies the free-energy landscape of P450cam channels toward favoring the diffusion of water molecules out of the protein active site. PMID:21943431
Goldblatt, Elizabeth; Wiles, Michael; Schwartz, Jan; Weeks, John
2013-01-01
The Academic Consortium for Complementary and Alternative Health Care (ACCAHC) is committed to advancing human health through the advancement and integration of the complementary and alternative medicine (CAM) professions within the American healthcare system. This will involve the maturation and integration of the licensed CAM professions into conventional healthcare delivery, and in turn, it will involve the development of competency in integrative healthcare and interprofessional education within the CAM professions. In 2010, ACCAHC resolved to identify the competencies necessary for this transformation, and in the process, discovered a parallel process of competency development within conventional healthcare, the Interprofessional Education Collaborative (IPEC), representing the six major conventional healthcare professions. The ACCAHC competency document, its development, and its similarity to the IPEC document are discussed. The ACCAHC competency document identified two domains of competence that were not present in the IPEC document: evidence-informed practice and institutional healthcare practices. These two domains of competency are discussed with respect to their significance in both CAM and conventional healthcare practices. ACCAHC's goal is to foster collaboration among its member professions and with conventional healthcare professions, and to use these competency documents to improve and optimize healthcare delivery, practices, and outcomes in America. It is hoped that ACCAHC's competency document will catalyze interaction with IPEC leading to the adoption of a single shared competency document that will meet the needs of all healthcare providers and educators. © 2013 Elsevier Inc. All rights reserved.
Fusion and Compatibility of Camphor and Octane Plasmids in Pseudomonas
Chou, George I. N.; Katz, Dvorah; Gunsalus, I. C.
1974-01-01
The octane (OCT) plasmid in Pseudomonas putida derived from the ω-hydroxylase-carrying strain of Coon and coworkers is transferable to the camphor (CAM) plasmid-bearing strain by conjugation or by transduction. While the majority of the Cam +Oct+ exconjugants segregate Cam+ or Oct+ cells, exconjugants with stable Cam +Oct+ phenotype (CAM-OCT) can be detected at a low frequency. The transductants are all of the CAM-OCT phenotype. In the stable Cam +Oct+ strains, the OCT plasmid resembles the CAM plasmid with respect to curing by mitomycin C, transfer in conjugation, and reaction to ts (temperature-sensitive) mutation specifically affecting CAM plasmid replication. Therefore, it is suggested that certain regions of homology exist between the CAM and OCT plasmids that enable them to recombine to form a single plasmid, and to overcome the incompatibility barrier that prevents their coexisting. PMID:4527812
Yamamoto, F; Harada, S; Mitsuyama, T; Harada, Y; Kitahara, Y; Yoshida, M; Nakanishi, Y
2004-02-01
Clarithromycin (CAM) and rifampicin (RFP) have both been recognized to be effective antibiotic agents against Mycobacterium avium complex (MAC) infection. Rifamycin derivatives including RFP and rifabutin modulate the CAM metabolism by inducing the hepatic cytochrome p-450 3A4. To clarify the effect of RFP on the CAM metabolism, we measured the plasma concentration of CAM and 14-R-hydroxyclarithromycin (M-5), the major metabolite of CAM, in 9 patients suffering from MAC infection before and after the addition of RFP. After the addition of RFP, the mean plasma concentration of CAM significantly decreased, while that of M-5 did not. In addition, the amount of CAM + M-5 concentration also significantly decreased. As M-5 is less effective against MAC infection than CAM, more attention should thus be paid to the plasma CAM concentration in patients administered CAM and RFP concomitantly.
The use of complementary and alternative medicine among people living with diabetes in Sydney.
Manya, Kiran; Champion, Bernard; Dunning, Trisha
2012-01-12
Complementary and alternative medicine (CAM) is common in patients with chronic disease such as diabetes mellitus. The primary objective of the study was to determine the overall prevalence and type of CAM use in individuals with diabetes mellitus (DM) in Western Sydney and to compare the prevalence and factors associated with CAM use with the literature. A multicenter cross-sectional study was undertaken using a self-completed questionnaire distributed to patients with DM attending a public hospital and specialist endocrinology clinics in the region. The type of DM and pattern of CAM utilisation were analyzed. Sixty nine people responded to the questionnaire: age range of 18-75 years during a twelve week collection period. Overall, 32 respondents with diabetes were using some form of CAM, resulting in a utilisation rate of 46.3%. Twenty of the 32 CAM users used CAM specifically to treat their diabetes accounting for 28.9% of the respondent sample population. Multivitamins (40%), cinnamon, Co-enzyme q10 and prayer were the most frequently used CAM modalities. There was no significant difference between males and females, age range, income or diabetes complications between CAM and non-CAM users. (p values each > 0.05) The factor most significantly associated with CAM usage was being born overseas (p = 0.044). Almost half the respondents (46.3%) used CAM: 28% used CAM specifically to treat their diabetes. Individuals born overseas were significantly more likely to use CAM than those born in Australia. Other factors such as age, gender, wealth and duration of living with diabetes were not associated with higher rate of CAM usage.
Complementary and alternative medicine use in radiotherapy: what are patients using?
Gillett, John; Ientile, Clare; Hiscock, Joanne; Plank, Ashley; Martin, Jarad M
2012-11-01
Complementary and alternative medicine (CAM) use by patients could interact in unpredictable ways with conventional therapies. This trial was designed to study the prevalence, types, and clinical implications of CAM use in patients with cancer who are receiving radiotherapy. A validated questionnaire was given to consenting outpatients in this ethics-approved study. Questions specified types of CAM used, clinician knowledge, reason for use, perceived effectiveness, safety, and cost. Of the 101 assessable questionnaires, 38 patients (38%) of the total patient group used CAM, with vitamins (53%), antioxidants (29%), spiritual/meditation practices (29%), and herbs (18%) being the most commonly used. The intention of CAM use was to improve quality of life in 69% of patients and for either hope of cure or to assist other forms of treatment in 26%. The majority of patients (58%) were using CAM prior to their diagnosis of cancer, with 40% starting at diagnosis or during conventional treatment. Patients spent up to $300/month on CAM use. Patients using CAM were significantly more likely to also receive chemotherapy versus non-CAM users (45% versus 24%, p=0.045). Significantly fewer CAM users expected cure from conventional therapy, compared to non-CAM users (50% versus 75%, p=0.016). More CAM users expected conventional therapy to prolong life (58% versus 32%, p<0.001). Only 40% discussed CAM use with their oncologists. CAM is commonly used by patients with cancer. CAMs, particularly antioxidants, are being taken which could negate the underlying free-radical tumorcidal effects of radiotherapy. Oncologists need to have greater awareness of this use and of its potential adverse consequences.
Newman, Rhonda A.; Sorensen, Brenda R.; Kilpatrick, Adina M.; Shea, Madeline A.
2014-01-01
Calmodulin (CaM) plays a vital role in calcium homeostasis by allosterically modulating intracellular calcium channels including the homo-tetrameric human Ryanodine Receptor Type 1 (hRyR1). Apo (calcium-free) CaM activates hRyR1 while calcium-saturated CaM inhibits it. Two CaM-binding regions (residues 1975–1999 and 3614–3643) identified in each RyR1 monomer were proposed to allow CaM to bridge adjacent RyR1 subunits. We explored the distinct roles of CaM domains by using fluorescence anisotropy to determine the affinity of CaM1–148 (full-length), CaM1–80 (N-domain) and CaM76–148 (C-domain) for peptides encompassing hRyR1 residues 1975–1999 or 3614–3643. Both CaM1–148 and CaM76–148 associated in a calcium-independent manner with similar affinities for hRyR1(3614–3643)p while CaM1–80 required calcium and bound ~250-fold more weakly. Association of CaM1–148, CaM1–80 and CaM76–148 with hRyR1(1975–1999)p was much less favorable than with hRyR1(3614–3643)p; differences between the two CaM domains were smaller. Equilibrium calcium titrations monitored by steady-state fluorescence demonstrated that both hRyR1 peptides increased the calcium-binding affinity of both CaM domains. These thermodynamic properties support a prior model in which the CaM C-domain associates with RyR1(3614–3643) at low levels of calcium, positioning CaM to rapidly respond to calcium efflux. However, the affinity of the N-domain of CaM for hRyR1(1975–1999)p is insufficient to explain a model in which CaM bridges adjacent RyR1 subunits within the tetramer. This indicates that other protein factors or properties of the tertiary or quaternary structure of hRyR1 contribute to the energetics of CaM-mediated regulation. PMID:25145833
AlGhamdi, Khalid M; Khurrum, Huma; Al-Natour, Sahar H; Alghamdi, Waleed; Mubki, Thamer; Alzolibani, Abdulatif; Hafez, Dhafer Mohammed Y; AlDraibi, Mohammed
2015-01-01
Little is known about the prevalence and practice of complementary and alternative medicine (CAM) among dermatology patients in the Arab world. The aim of this study was to determine knowledge and attitudes about CAM, prevalence of its use, reasons for its use, and types of CAM used in dermatology patients in Saudi Arabia. This was a national survey of various regions of Saudi Arabia. In this cross-sectional study, dermatology outpatients were interviewed using a questionnaire. Sociodemographic characteristics, acceptability, utilization pattern, and reasons for CAM use were elicited. Dermatology life quality index (DLQI) was obtained. Overall, 1901 patients returned complete questionnaires out of 2500 distributed (76% response rate). Of these, 808 (40%) were CAM users, and the majority were woman (55.1%), with a mean age of 31.6±12 years. Most were literate (71.2%) and just over half were married (51.9%). Patients with acute skin diseases were found to be more likely to use CAM (P=.027). The mean DLQI score was higher (worse quality of life) among CAM users than among nonusers (P=.002). The results showed that 315 of 801 (40%) and 250 of 601 (30%) CAM users agreed that CAM methods are safer and more effective than modern medicine, respectively, and 83% will continue to use CAM in future. The most commonly used CAM modalities were vitamins, prayers, natural products, and herbs. Responses indicated that 379 of 803 (47.2%) CAM users did not consult their doctor before using CAM, and 219 of 743 (30%) did not obtain sufficient answers regarding CAM use from their dermatologists. There is a significant use of CAM among dermatology outpatients in Saudi Arabia. In view of the common belief that CAM has fewer side effects than conventional medicine, dermatologists need to increase their awareness of CAM. © The Author(s) 2015.
Sandau, Ursula S.; Mungenast, Alison E.; McCarthy, Jack; Biederer, Thomas; Corfas, Gabriel
2011-01-01
We previously identified synaptic cell adhesion molecule 1 (SynCAM1) as a component of a genetic network involved in the hypothalamic control of female puberty. Although it is well established that SynCAM1 is a synaptic adhesion molecule, its contribution to hypothalamic function is unknown. Here we show that, in addition to the expected neuronal localization illustrated by its presence in GnRH neurons, SynCAM1 is expressed in hypothalamic astrocytes. Cell adhesion assays indicated that SynCAM is recognized by both GnRH neurons and astrocytes as an adhesive partner and promotes cell-cell adhesiveness via homophilic, extracellular domain-mediated interactions. Alternative splicing of the SynCAM1 primary mRNA transcript yields four mRNAs encoding membrane-spanning SynCAM1 isoforms. Variants 1 and 4 are predicted to be both N and O glycosylated. Hypothalamic astrocytes and GnRH-producing GT1-7 cells express mainly isoform 4 mRNA, and sequential N- and O-deglycosylation of proteins extracted from these cells yields progressively smaller SynCAM1 species, indicating that isoform 4 is the predominant SynCAM1 variant expressed in astrocytes and GT1-7 cells. Neither cell type expresses the products of two other SynCAM genes (SynCAM2 and SynCAM3), suggesting that SynCAM-mediated astrocyte-astrocyte and astrocyte-GnRH neuron adhesiveness is mostly mediated by SynCAM1 homophilic interactions. When erbB4 receptor function is disrupted in astrocytes, via transgenic expression of a dominant-negative erbB4 receptor form, SynCAM1-mediated adhesiveness is severely compromised. Conversely, SynCAM1 adhesive behavior is rapidly, but transiently, enhanced in astrocytes by ligand-dependent activation of erbB4 receptors, suggesting that erbB4-mediated events affecting SynCAM1 function contribute to regulate astrocyte adhesive communication. PMID:21486931
2013-01-01
Background Complementary and alternative medicine (CAM) is commonly used in China for the management of coronary artery disease (CAD). However, few studies have been conducted to investigate the prevalence, perceived effectiveness, types, and reasons of CAM use in patients diagnosed with CAD. Methods A cross-sectional study design was adopted. Questionnaires were distributed at the outpatient cardiac clinics of four tertiary-level teaching general hospitals in Beijing. Quantitative data were analyzed using Student’s t-test. Categorical data were analyzed using chi-square test. Logistic regression was employed to explore factors associated with the use of CAM as well as CAM use features in Chinese medicine (CM) hospitals when significant differences were found upon comparisons. Results From May to July, 2009, a total of 600 questionnaires were distributed, and 546 patients with a diagnosis of CAD responded with valid values and were included in the present study. CAM was used by 69.1% of the patients with CAD; the majority (75.9%) of these CAM users believes that CAM is effective. “Few side effects” (49.6%) was the main reason of CAM use; whereas “doubt of effect” (61.5%) was the main reason for non-use. Patent herbal medicine (90.7%) was the most commonly used CAM type. Compared with non-CAM users, CAM users tended to be older (p < 0.01), have a longer disease duration (p = 0.02) and better current health status. In addition, CAM users had significant lower odds for emergency admission and hospitalization within the past one year. Patients with CAD from CM and WM hospitals differ in CAM use frequency, types, perceived effectiveness, as well as reasons for CAM use or non-CAM use. Conclusion The present study suggested a group of significant factors which could influence the use of CAM in patients with CAD. CAM use patterns differ in patients from CM and WM hospitals. PMID:24160843
The role of complementary and alternative medicine (CAM) in Germany - a focus group study of GPs.
Joos, Stefanie; Musselmann, Berthold; Miksch, Antje; Rosemann, Thomas; Szecsenyi, Joachim
2008-06-12
There has been a marked increase in the use of complementary and alternative medicine (CAM) in recent years worldwide. In Germany, apart from 'Heilpraktiker' (= state-licensed, non-medical CAM practitioners), some general practitioners (GPs) provide CAM in their practices. This paper aims to explore the attitudes of GPs about the role of CAM in Germany, in relation to the healthcare system, quality of care, medical education and research. Furthermore, experiences of GPs integrating CAM in their daily practice were explored. Using a qualitative methodological approach 3 focus groups with a convenience sample of 17 GPs were conducted. The discussions were transcribed verbatim and analysed using qualitative content analysis. The majority of the participating GPs had integrated one or more CAM therapies into their every-day practice. Four key themes were identified based on the topics covered in the focus groups: the role of CAM within the German healthcare system, quality of care, education and research. Within the theme 'role of CAM within the healthcare system' there were five categories: integration of CAM, CAM in the Statutory Health Insurance, modernisation of the Statutory Health Insurance Act, individual healthcare services and 'Heilpraktiker'. Regarding quality of care there were two broad groups of GPs: those who thought patients would benefit from standardizing CAM and those who feared that quality control would interfere with the individual approach of CAM. The main issues identified relating to research and education were the need for the development of alternative research strategies and the low quality of existing CAM education respectively. The majority of the participating GPs considered CAM as a reasonable complementary approach within primary care. The study increased our understanding of GPs attitudes about the role of CAM within the German healthcare system and the use of 'Heilpraktiker' as a competing CAM-provider. It seems to be a need for increased funding for research, better education and remuneration by the Statutory Health Insurance in order to improve access to 'Integrative medicine' in Germany.
2013-01-01
Background Complementary and alternative medicine (CAM) use in patients with IBD is on the increase. Patients report they use CAM when their condition is unresponsive to conventional medication or when they suffer from side-effects, negative stress and disease-related concerns. CAM use may improve patients’ well-being but it can also lead to side-effects and interactions with conventional medications. Research on attitudes to and experiences of CAM among healthcare professionals working with IBD patients is not well studied. Studies in this area could lead to enhanced awareness of and improved communication about CAM between care staff and IBD patients. The aim of this study was to explore IBD professionals’ attitudes to and experience of CAM. Methods Sixteen physicians and nurses, 26–70 years old, who had worked with IBD patients for 1–42 years, were recruited. Semi-structured qualitative interviews were conducted. Qualitative content analysis was performed. Results Participants stated patients used CAM to improve their well-being generally and there conditions specifically. Participants had a positive attitude towards CAM and respected their patients’ decision to use it, but reported a lack of CAM knowledge. They required education about CAM to be able to meet patients’ needs and provide adequate information. The result of this study indicates that there is a need for CAM education to be implemented in nursing and medical school. Conclusions All participants had experience of IBD patients who had used CAM in an attempt to achieve improvement and well-being. Attitudes to CAM were mainly positive, although a problematic aspect was lack of knowledge and evidence in relation to CAM. Implementing CAM education in nursing and medical school will allow healthcare professionals to gain an understanding of therapies widely used by patients with IBD. In clinical practice, using a standard questionnaire regarding CAM use allow healthcare professionals to better understand their patients’ wishes and current CAM use. PMID:24325595
Taiwanese adult cancer patients' reports of using complementary therapies.
Lu, Jui-Hua; Tsay, Shiow-Luan; Sung, Su-Ching
2010-01-01
More information is needed by cancer clinicians regarding cancer patients' use of complementary and alternative medicine (CAM). In this qualitative study, in-depth interviews were used to obtain the reports of adult cancer patients regarding their use of CAM. Seven cancer patients (4 women, 3 men) who reported using CAM were recruited by snowball sampling. Content analysis was used to examine the interview transcriptions. Five themes and multiple categories were identified related to CAM use: (1) facing the challenges of cancer (I can't be defeated, need to cooperate with conventional medical treatment, rebuilding my confidence), (2) handling the physical and psychological distress of CAM use (extra loading due to the therapy, uncertainty and fear about the efficacy of CAM, being understood and supported, feeling guilty about being sick, (3) lifestyle disruption (altering social life, changing family living style), (4) having reasons for seeking other therapies (finding a way to cure the disease, boosting my immunity, improving my overall health status, and prolonging life and searching for peace of mind), and (5) unresolved practical concerns about CAM (finding an easy and effective way to practice CAM, needing CAM to be integrated into mainstream health care, and where to get the related information). Adult Taiwanese cancer patients who use CAM do experience burdens secondary to CAM use and prefer that oncology specialists be more informed about CAM. Oncology specialists who know where adult cancer patients could obtain helpful information about CAM would help to decrease the burdens that patients who use CAM experience.
Merenstein, Daniel; Yang, Yang; Schneider, Michael F.; Goparaju, Lakshmi; Weber, Kathleen; Sharma, Anjali; Levine, Alexandra M.; Sharp, Gerald B.; Gandhi, Monica; Liu, Chenglong
2009-01-01
Objective To assess whether complementary and alternative medicine (CAM) use is associated with the timing of highly active antiretroviral therapy (HAART) initiation among human immunodeficiency virus (HIV)–infected participants of the Women’s Interagency HIV Study. Study Methods Prospective cohort study between January 1996 and March 2002. Differences in the cumulative incidence of HAART initiation were compared between CAM users and non–CAM users using a logrank test. Cox regression model was used to assess associations of CAM exposures with time to HAART initiation. Main Outcome and Exposures Study outcome was time from January 1996 to initiation of HAART. Primary exposure was use of any CAM modality before January 1996, and secondary exposures included the number and type of CAM modalities used (ingestible CAM medication, body practice, or spiritual healing) during the same period. Results One thousand thirty-four HIV-infected women contributed a total of 4987 person-visits during follow-up. At any time point, the cumulative incidence of HAART initiation among CAM users was higher than that among non–CAM users. After adjustment for potential confounders, those reporting CAM use were 1.34 times (95% confidence interval: 1.09, 1.64) more likely to initiate HAART than non–CAM users. Conclusion Female CAM users initiated HAART regimens earlier than non–CAM users. Initiation of HAART is an important clinical marker, but more research is needed to elucidate the role specific CAM modalities play in HIV disease progression. PMID:18780580
Optical Aptamer Probes of Fluorescent Imaging to Rapid Monitoring of Circulating Tumor Cell
Hwang, Ji Yeon; Kim, Sang Tae; Han, Ho-Seong; Kim, Kyunggon; Han, Jin Soo
2016-01-01
Fluorescence detecting of exogenous EpCAM (epithelial cell adhesion molecule) or muc1 (mucin1) expression correlated to cancer metastasis using nanoparticles provides pivotal information on CTC (circulating tumor cell) occurrence in a noninvasive tool. In this study, we study a new skill to detect extracellular EpCAM/muc1 using quantum dot-based aptamer beacon (QD-EpCAM/muc1 ALB (aptamer linker beacon). The QD-EpCAM/muc1 ALB was designed using QDs (quantum dots) and probe. The EpCAM/muc1-targeting aptamer contains a Ep-CAM/muc1 binding sequence and BHQ1 (black hole quencher 1) or BHQ2 (black hole quencher2). In the absence of target EpCAM/muc1, the QD-EpCAM/muc1 ALB forms a partial duplex loop-like aptamer beacon and remained in quenched state because the BHQ1/2 quenches the fluorescence signal-on of the QD-EpCAM/muc1 ALB. The binding of EpCAM/muc1 of CTC to the EpCAM/muc1 binding aptamer sequence of the EpCAM/muc1-targeting oligonucleotide triggered the dissociation of the BHQ1/2 quencher and subsequent signal-on of a green/red fluorescence signal. Furthermore, acute inflammation was stimulated by trigger such as caerulein in vivo, which resulted in increased fluorescent signal of the cy5.5-EpCAM/muc1 ALB during cancer metastasis due to exogenous expression of EpCAM/muc1 in Panc02-implanted mouse model. PMID:27886058
Sanchez, Marciano; Karnae, Saritha; John, Kuruvilla
2008-01-01
Selected Volatile Organic Compounds (VOC) emitted from various anthropogenic sources including industries and motor vehicles act as primary precursors of ozone, while some VOC are classified as air toxic compounds. Significantly large VOC emission sources impact the air quality in Corpus Christi, Texas. This urban area is located in a semi-arid region of South Texas and is home to several large petrochemical refineries and industrial facilities along a busy ship-channel. The Texas Commission on Environmental Quality has setup two continuous ambient monitoring stations (CAMS 633 and 634) along the ship channel to monitor VOC concentrations in the urban atmosphere. The hourly concentrations of 46 VOC compounds were acquired from TCEQ for a comprehensive source apportionment study. The primary objective of this study was to identify and quantify the sources affecting the ambient air quality within this urban airshed. Principal Component Analysis/Absolute Principal Component Scores (PCA/APCS) was applied to the dataset. PCA identified five possible sources accounting for 69% of the total variance affecting the VOC levels measured at CAMS 633 and six possible sources affecting CAMS 634 accounting for 75% of the total variance. APCS identified natural gas emissions to be the major source contributor at CAMS 633 and it accounted for 70% of the measured VOC concentrations. The other major sources identified at CAMS 633 included flare emissions (12%), fugitive gasoline emissions (9%), refinery operations (7%), and vehicle exhaust (2%). At CAMS 634, natural gas sources were identified as the major source category contributing to 31% of the observed VOC. The other sources affecting this site included: refinery operations (24%), flare emissions (22%), secondary industrial processes (12%), fugitive gasoline emissions (8%) and vehicle exhaust (3%). PMID:19139530
1994-01-01
L-selectin is a lectin-like receptor that mediates the attachment of lymphocytes to high endothelial venules (HEV) of lymph nodes during the process of lymphocyte recirculation. Two sulfated, mucin-like glycoproteins known as Sgp50/GlyCAM-1 and Sgp90/CD34 have previously been identified as HEV-associated ligands for L-selectin. These proteins were originally detected with an L-selectin/Ig chimera called LEC-IgG. GlyCAM-1 and CD34 are also recognized by an antiperipheral node addressin (PNAd) mAb called MECA 79, which blocks L-selectin- dependent adhesion and selectively stains lymph node HEV. The present study compares the requirements for the binding of MECA 79 and LEC-IgG to HEV-ligands. Whereas desialylation of GlyCAM-1 and CD34 drastically reduced binding to LEC-IgG, this treatment enhanced the binding of GlyCAM-1 to MECA 79. In contrast, the binding of both MECA 79 and LEC- IgG to GlyCAM-1 and CD34 was greatly decreased when the sulfation of these ligands was reduced with chlorate, a metabolic inhibitor of sulfation. Because MECA 79 stains HEV-like vessels at various sites of inflammation, recognition by L-selectin of ligands outside of secondary lymphoid organs may depend on sulfation. In addition to their reactivity with GlyCAM-1 and CD34, both MECA 79 and LEC-IgG recognize an independent molecule of approximately 200 kD in a sulfate-dependent manner. Thus, this molecule, which we designate Sgp200, is an additional ligand for L-selectin. PMID:7525849
Genes encoding calmodulin-binding proteins in the Arabidopsis genome
NASA Technical Reports Server (NTRS)
Reddy, Vaka S.; Ali, Gul S.; Reddy, Anireddy S N.
2002-01-01
Analysis of the recently completed Arabidopsis genome sequence indicates that approximately 31% of the predicted genes could not be assigned to functional categories, as they do not show any sequence similarity with proteins of known function from other organisms. Calmodulin (CaM), a ubiquitous and multifunctional Ca(2+) sensor, interacts with a wide variety of cellular proteins and modulates their activity/function in regulating diverse cellular processes. However, the primary amino acid sequence of the CaM-binding domain in different CaM-binding proteins (CBPs) is not conserved. One way to identify most of the CBPs in the Arabidopsis genome is by protein-protein interaction-based screening of expression libraries with CaM. Here, using a mixture of radiolabeled CaM isoforms from Arabidopsis, we screened several expression libraries prepared from flower meristem, seedlings, or tissues treated with hormones, an elicitor, or a pathogen. Sequence analysis of 77 positive clones that interact with CaM in a Ca(2+)-dependent manner revealed 20 CBPs, including 14 previously unknown CBPs. In addition, by searching the Arabidopsis genome sequence with the newly identified and known plant or animal CBPs, we identified a total of 27 CBPs. Among these, 16 CBPs are represented by families with 2-20 members in each family. Gene expression analysis revealed that CBPs and CBP paralogs are expressed differentially. Our data suggest that Arabidopsis has a large number of CBPs including several plant-specific ones. Although CaM is highly conserved between plants and animals, only a few CBPs are common to both plants and animals. Analysis of Arabidopsis CBPs revealed the presence of a variety of interesting domains. Our analyses identified several hypothetical proteins in the Arabidopsis genome as CaM targets, suggesting their involvement in Ca(2+)-mediated signaling networks.
Field Test of the ExoMars Panoramic Camera in the High Arctic - First Results and Lessons Learned
NASA Astrophysics Data System (ADS)
Schmitz, N.; Barnes, D.; Coates, A.; Griffiths, A.; Hauber, E.; Jaumann, R.; Michaelis, H.; Mosebach, H.; Paar, G.; Reissaus, P.; Trauthan, F.
2009-04-01
The ExoMars mission as the first element of the ESA Aurora program is scheduled to be launched to Mars in 2016. Part of the Pasteur Exobiology Payload onboard the ExoMars rover is a Panoramic Camera System (‘PanCam') being designed to obtain high-resolution color and wide-angle multi-spectral stereoscopic panoramic images from the mast of the ExoMars rover. The PanCam instrument consists of two wide-angle cameras (WACs), which will provide multispectral stereo images with 34° field-of-view (FOV) and a High-Resolution RGB Channel (HRC) to provide close-up images with 5° field-of-view. For field testing of the PanCam breadboard in a representative environment the ExoMars PanCam team joined the 6th Arctic Mars Analogue Svalbard Expedition (AMASE) 2008. The expedition took place from 4-17 August 2008 in the Svalbard archipelago, Norway, which is considered to be an excellent site, analogue to ancient Mars. 31 scientists and engineers involved in Mars Exploration (among them the ExoMars WISDOM, MIMA and Raman-LIBS team as well as several NASA MSL teams) combined their knowledge, instruments and techniques to study the geology, geophysics, biosignatures, and life forms that can be found in volcanic complexes, warm springs, subsurface ice, and sedimentary deposits. This work has been carried out by using instruments, a rover (NASA's CliffBot), and techniques that will/may be used in future planetary missions, thereby providing the capability to simulate a full mission environment in a Mars analogue terrain. Besides demonstrating PanCam's general functionality in a field environment, test and verification of the interpretability of PanCam data for in-situ geological context determination and scientific target selection was a main objective. To process the collected data, a first version of the preliminary PanCam 3D reconstruction processing & visualization chain was used. Other objectives included to test and refine the operational scenario (based on ExoMars Rover Reference Surface Mission), to investigate data commonalities and data fusion potential w.r.t. other instruments, and to collect representative image data to evaluate various influences, such as viewing distance, surface structure, and availability of structures at "infinity" (e.g. resolution, focus quality and associated accuracy of the 3D reconstruction). Airborne images with the HRSC-AX camera (airborne camera with heritage from the Mars Express High Resolution Stereo Camera HRSC), collected during a flight campaign over Svalbard in June 2008, provided large-scale geological context information for all field sites.
Complementary and alternative health care in Israel
2012-01-01
The paper explores the patterns of coexistence of alternative/complementary health care (CAM) and conventional medicine in Israel in the cultural, political, and social contexts of the society. The data are drawn from over ten years of sociological research on CAM in Israel, which included observation, survey research, and over one hundred in-depth interviews with a variety of CAM practitioners - many with bio-medical credentials - and with policy makers in the major medical institutions. The analysis considers the reasons for CAM use, number of practitioners, the frequency of CAM use and some of its correlates, and how CAM is regulated. The structure of the relationship between the conventional health care system and CAM is discussed in the public sector, which provides two-thirds of CAM services, and in the private sector, which provides about one-third. The history of the development of these structures and some of the dilemmas of their operation are discussed. A number of policy issues are considered against this background: regulation and licensing, CAM in primary care, reimbursement for CAM treatment, and the inclusion of CAM in education and training for the health professions. PMID:22913721
Tippens, Kim; Marsman, Kevin; Zwickey, Heather
2009-04-01
Alternative medicine researchers and policy makers have classified prayer as a mind-body intervention, and thus, a modality of complementary and alternative medicine (CAM). As such, numerous epidemiological surveys of CAM utilization-which have included prayer-depict increasing CAM use, particularly in specific racial and ethnic groups. This paper discusses the implications of conflating prayer and CAM, especially regarding the definitions of both concepts and the resulting statistics of CAM utilization.
2012-01-01
Background Complementary and alternative medicine (CAM) is widely used for the treatment of infertility. While the Middle East and North Africa region has been shown to house one of the fastest growing markets of CAM products in the world, research describing the use of CAM therapies among Middle-Eastern infertile patients is minimal. The aim of this study is to examine the prevalence, characteristics and determinants of CAM use among infertile patients in Lebanon. Methods A cross sectional survey design was used to carry out face-to-face interviews with 213 consecutive patients attending the Assisted Reproductive Unit at a major academic medical center in Beirut. The questionnaire comprised three sections: socio-demographic and lifestyle characteristics, infertility-related aspects and information on CAM use. The main outcome measure was the use of CAM modalities for infertility treatment. Determinants of CAM use were assessed through the logistic regression method. Results Overall, 41% of interviewed patients reported using a CAM modality at least once for their infertility. There was a differential by gender in the most commonly used CAM therapies; where males mostly used functional foods (e.g. honey & nuts) (82.9%) while females mostly relied on spiritual healing/prayer (56.5%). Factors associated with CAM use were higher household income (OR: 0.305, 95% CI: 0.132–0.703) and sex, with females using less CAM than males (OR: 0.12, 95% CI: 0.051–0.278). The older patients were diagnosed with infertility, the lower the odds of CAM use (p for trend <0.05). Almost half of the participants (48%) were advised on CAM use by their friends, and only 13% reported CAM use to their physician. Conclusions The considerably high use of CAM modalities among Lebanese infertile patients, added to a poor CAM use disclosure to physicians, underscore the need to integrate CAM into the education and training of health professionals, as well as enhance infertile patients' awareness on safe use of CAM products. PMID:22901284
Shumer, Gregory; Warber, Sara; Motohara, Satoko; Yajima, Ayaka; Plegue, Melissa; Bialko, Matthew; Iida, Tomoko; Sano, Kiyoshi; Amenomori, Masaki; Tsuda, Tsukasa; Fetters, Michael D
2014-09-25
There is growing interest in the use of complementary and alternative medicine (CAM) throughout the world, however previous research done in Japan has focused primarily on CAM use in major cities. The purpose of this study was to develop and distribute a Japanese version of the International Complementary and Alternative Medicine Questionnaire (I-CAM-Q) to assess the use of CAM among people who visit rural Japanese family medicine clinics. Using a Japanese version of the International Complementary and Alternative Medicine Questionnaire (I-CAM-Q), a cross-sectional survey was conducted in three rural family medicine clinics. All patients and those accompanying patients who met inclusion criteria were eligible to participate. Data were entered into SPSS Statistics and analyzed for use by age, gender, and location. Of the 519 respondents who participated in the project, 415 participants reported CAM use in the past 12 months (80.0%). When prayer is excluded, the prevalence of CAM use drops to 77.3% in the past year, or 403 respondents. The most common forms of CAM used by respondents were pain relief pads (n = 170, 32.8%), herbal medicines/supplements (n = 167, 32.2%), and massage by self or family (n = 166, 32.0%). Female respondents, individuals with higher levels of education, and those with poorer overall health status were more likely to use CAM than respondents without these characteristics. Only 22.8% of CAM therapies used were reported to physicians by survey participants. These data indicate that CAM use in rural Japan is common. The results are consistent with previous studies that show that Japanese individuals are more interested in forms of CAM such as pain relief pads and massage, than in mind-body forms of CAM like relaxation and meditation. Due to the high utilization of certain CAM practices, and given that most CAM users do not disclose their CAM use to their doctors, we conclude that physicians in rural Japan would benefit by asking about CAM use during patient interviews, and by familiarizing themselves with the potential benefits and risks of commonly used CAM modalities.
Yang, Xiaohan; Cushman, John C; Borland, Anne M; Edwards, Erika J; Wullschleger, Stan D; Tuskan, Gerald A; Owen, Nick A; Griffiths, Howard; Smith, J Andrew C; De Paoli, Henrique C; Weston, David J; Cottingham, Robert; Hartwell, James; Davis, Sarah C; Silvera, Katia; Ming, Ray; Schlauch, Karen; Abraham, Paul; Stewart, J Ryan; Guo, Hao-Bo; Albion, Rebecca; Ha, Jungmin; Lim, Sung Don; Wone, Bernard W M; Yim, Won Cheol; Garcia, Travis; Mayer, Jesse A; Petereit, Juli; Nair, Sujithkumar S; Casey, Erin; Hettich, Robert L; Ceusters, Johan; Ranjan, Priya; Palla, Kaitlin J; Yin, Hengfu; Reyes-García, Casandra; Andrade, José Luis; Freschi, Luciano; Beltrán, Juan D; Dever, Louisa V; Boxall, Susanna F; Waller, Jade; Davies, Jack; Bupphada, Phaitun; Kadu, Nirja; Winter, Klaus; Sage, Rowan F; Aguilar, Cristobal N; Schmutz, Jeremy; Jenkins, Jerry; Holtum, Joseph A M
2015-08-01
Crassulacean acid metabolism (CAM) is a specialized mode of photosynthesis that features nocturnal CO2 uptake, facilitates increased water-use efficiency (WUE), and enables CAM plants to inhabit water-limited environments such as semi-arid deserts or seasonally dry forests. Human population growth and global climate change now present challenges for agricultural production systems to increase food, feed, forage, fiber, and fuel production. One approach to meet these challenges is to increase reliance on CAM crops, such as Agave and Opuntia, for biomass production on semi-arid, abandoned, marginal, or degraded agricultural lands. Major research efforts are now underway to assess the productivity of CAM crop species and to harness the WUE of CAM by engineering this pathway into existing food, feed, and bioenergy crops. An improved understanding of CAM has potential for high returns on research investment. To exploit the potential of CAM crops and CAM bioengineering, it will be necessary to elucidate the evolution, genomic features, and regulatory mechanisms of CAM. Field trials and predictive models will be required to assess the productivity of CAM crops, while new synthetic biology approaches need to be developed for CAM engineering. Infrastructure will be needed for CAM model systems, field trials, mutant collections, and data management. © 2015 ORNL/UT-Battelle New Phytologist © 2015 New Phytologist Trust.
Chao, Maria T.; Wade, Christine M.
2014-01-01
Objective Higher socioeconomic status (SES) is associated with using complementary and alternative medicine (CAM) in national surveys. Less is known about how socioeconomic factors affect CAM use in US subpopulations. We examined whether the relationship between SES and CAM use differs by racial/ethnic groups. Methods Using national survey data, we assessed education and income effects on women's CAM use in four racial/ethnic groups (Whites, Blacks, Mexican Americans, and Chinese Americans), controlling for age, health status, and geographic region. CAM use was defined as using any of 11 domains in the prior year. Results Adjusted effects of SES on CAM use were similar among Mexican American and non-Hispanic White women—education had a distinct gradient effect, with each increasing level of education significantly more likely to use CAM; household income ≥$60,000 was associated with CAM use compared to income <$20,000. For Chinese American women, socioeconomic factors were not associated with CAM use when controlling for confounders. Although income was not associated with CAM use among African American women, college graduates were three times more likely to use CAM than those with less than a high school education, adjusting for confounders. Conclusion SES effects on CAM use are not uniform across racial/ethnic populations. Other factors, such as culture and social networks, may interact with SES to influence CAM use in minority populations. PMID:18447102
Corina, Güthlin; Christine, Holmberg; Klein, Gudrun
2016-09-01
The rising use of complementary and alternative medicine (CAM) means oncologists are increasingly asked by patients to discuss CAM treatment options. However, no formal training or established standards are available on the subject. The aim of this paper was to investigate real-world discussions of CAM treatments. In particular, we wanted to learn about the values, norms and defining features that characterise oncologist-patient discussions on CAM. Semi-standardised interviews with 17 oncologists were analysed using interpretation pattern analysis combined with thematic analysis. Advice on CAM is seen by oncologists as an important service they provide to their patients, even though their knowledge of the subject is often limited. Many interviewees mentioned an apparent lack of scientific proof, especially when their aim was to warn patients against the use of CAM. Discussions on CAM tend to reflect the idea that CAM belongs 'to another world', and judging by the interviews with oncologists, this notion appears to be shared by patients and oncologists alike. Oncologists require reliable information on CAM and would profit from training in the communication of CAM treatment options to patients. Knowing scientific data on CAM would also lower barriers stemming from the view that CAM belongs 'to another world'. Under- and postgraduate education programmes should include training on how to respond to requests addressing possible CAM options.
Tayama, Shingo; Motohara, Takeshi; Narantuya, Dashdemberel; Li, Chenyan; Fujimoto, Koichi; Sakaguchi, Isao; Tashiro, Hironori; Saya, Hideyuki; Nagano, Osamu; Katabuchi, Hidetaka
2017-07-04
Epithelial ovarian cancer is a highly lethal malignancy; moreover, overcoming chemoresistance is the major challenging in treating ovarian cancer patients. The cancer stem cell (CSC) hypothesis considers CSCs to be the main culprits in driving tumor initiation, metastasis, and resistance to conventional therapy. Although growing evidence suggest that CSCs are responsible for chemoresistance, the contribution of CSC marker EpCAM to resistance to chemotherapy remains unresolved.Here we have demonstrated that ovarian cancers containing high levels of EpCAM have a significantly much lower probability of achieving overall responsive rates after first-line chemotherapy. In addition, multivariate analysis revealed that EpCAM expression is an independent risk factor for chemoresistance, indicating that EpCAM expression is a predictive biomarker of chemotherapeutic response. Consistent with these clinical observations, in vitro assays, we found that the subpopulation of EpCAM-positive ovarian cancer cells shows a significantly higher viability compared with EpCAM-negative cells in response to cisplatin treatment by preventing chemotherapy-induced apoptosis, which is regulated by EpCAM-Bcl-2 axis. Furthermore, in an in vivo mouse model, platinum agents preferentially eliminated EpCAM-negative cells in comparison with EpCAM-positive cells, suggesting that the remaining subpopulation of EpCAM-positive cells contributes to tumor recurrence after chemotherapy. Finally, we also found that an increased expression of EpCAM is associated with poor prognosis in ovarian cancer patients.Our findings highlight the clinical significance of EpCAM in the resistance to chemotherapy and provide a rationale for EpCAM-targeted therapy to improve chemoresistance. Targeting EpCAM should be a promising approach to effectively extirpate the CSCs as the putative root of ovarian cancer.
Brambila-Tapia, Aniel Jessica Leticia; Rios-Gonzalez, Blanca Estela; Lopez-Barragan, Liliana; Saldaña-Cruz, Ana Miriam; Rodriguez-Vazquez, Katya
2016-01-01
The use of complementary and alternative medicine (CAM) has increased in many countries, and this has altered the knowledge, attitudes, and treatment recommendations of health professionals in regard to CAM. Considering Mexican health professionals׳ lack of knowledge of CAM, in this report we surveyed 100 biomedical researchers and Ph.D. students and 107 specialized physicians and residents of a medical specialty in Guadalajara, México (Western Mexico) with a questionnaire to address their attitudes, knowledge, use, and recommendation of CAM. We observed that significantly more researchers had ever used CAM than physicians (83% vs. 69.2%, P = .023) and that only 36.4% of physicians had ever recommended CAM. Female researchers tended to have ever used CAM more than male researchers, but CAM use did not differ between genders in the physician group or by age in either group. Homeopathy, herbal medicine, and massage therapy were the most commonly used CAMs in both the groups. Physicians more frequently recommended homeopathy, massage therapy, and yoga to their patients than other forms of CAM, and physicians had the highest perception of safety and had taken the most courses in homeopathy. All CAMs were perceived to have high efficacy (>60%) in both the groups. The attitude questionnaire reported favorable attitudes toward CAM in both the groups. We observed a high rate of Mexican health professionals that had ever used CAM, and they had mainly used homeopathy, massage therapy, and herbal medicine. However, the recommendation rate of CAM by Mexican physicians was significantly lower than that in other countries, which is probably due to the lack of CAM training in most Mexican medical schools. Copyright © 2016 Elsevier Inc. All rights reserved.
EpCAM expression in primary tumour tissues and metastases: an immunohistochemical analysis.
Spizzo, Gilbert; Fong, Dominic; Wurm, Martin; Ensinger, Christian; Obrist, Peter; Hofer, Carina; Mazzoleni, Guido; Gastl, Guenther; Went, Philip
2011-05-01
Epithelial cell adhesion molecule (EpCAM) is a cell surface protein with oncogenic features that is expressed on healthy human epithelia and corresponding malignant tumours. EpCAM expression frequently correlates with more aggressive tumour behaviour and new EpCAM-specific therapeutic agents have recently been approved for clinical use in patients with cancer. However, no consensus exists on how and when to evaluate EpCAM expression in patients with cancer. EpCAM expression was assessed by a well-established immunohistochemical staining protocol in 2291 primary tumour tissues and in 108 metastases using the EpCAM-specific antibody clone VU1D9. A total immunostaining score was calculated as the product of a proportion score and an intensity score. Four expression subgroups (no, weak, moderate and intense) were defined. As described previously, the term 'EpCAM overexpression' was reserved for tissues showing a total immunostaining score >4. EpCAM was highly expressed in most tumours of gastrointestinal origin and in some carcinomas of the genitourinary tract. However, hepatocellular carcinomas, clear cell renal cell cancer, urothelial cancer and squamous cell cancers were frequently EpCAM negative. EpCAM expression in breast cancer depended on the histological subtype; lobular histology usually showed no or weak expression. Most metastases were EpCAM positive and they frequently reflected the expression phenotype of the primary tumour. EpCAM expression was detected on adenocarcinomas of various primary sites. If EpCAM-specific antibodies are intended to be used in patients with cancer, we recommend prior immunohistochemical evaluation of EpCAM expression, particularly in patients with renal cell cancer, hepatocellular carcinoma, urothelial carcinoma, breast cancer and squamous cell carcinomas.
The use of complementary and alternative medicine among people living with diabetes in Sydney
2012-01-01
Background Complementary and alternative medicine (CAM) is common in patients with chronic disease such as diabetes mellitus. The primary objective of the study was to determine the overall prevalence and type of CAM use in individuals with diabetes mellitus (DM) in Western Sydney and to compare the prevalence and factors associated with CAM use with the literature. Methods A multicenter cross-sectional study was undertaken using a self-completed questionnaire distributed to patients with DM attending a public hospital and specialist endocrinology clinics in the region. The type of DM and pattern of CAM utilisation were analyzed. Results Sixty nine people responded to the questionnaire: age range of 18-75 years during a twelve week collection period. Overall, 32 respondents with diabetes were using some form of CAM, resulting in a utilisation rate of 46.3%. Twenty of the 32 CAM users used CAM specifically to treat their diabetes accounting for 28.9% of the respondent sample population. Multivitamins (40%), cinnamon, Co-enzyme q10 and prayer were the most frequently used CAM modalities. There was no significant difference between males and females, age range, income or diabetes complications between CAM and non-CAM users. (p values each > 0.05) The factor most significantly associated with CAM usage was being born overseas (p = 0.044). Conclusions Almost half the respondents (46.3%) used CAM: 28% used CAM specifically to treat their diabetes. Individuals born overseas were significantly more likely to use CAM than those born in Australia. Other factors such as age, gender, wealth and duration of living with diabetes were not associated with higher rate of CAM usage. PMID:22240113
Lacie phase 1 Classification and Mensuration Subsystem (CAMS) rework experiment
NASA Technical Reports Server (NTRS)
Chhikara, R. S.; Hsu, E. M.; Liszcz, C. J.
1976-01-01
An experiment was designed to test the ability of the Classification and Mensuration Subsystem rework operations to improve wheat proportion estimates for segments that had been processed previously. Sites selected for the experiment included three in Kansas and three in Texas, with the remaining five distributed in Montana and North and South Dakota. The acquisition dates were selected to be representative of imagery available in actual operations. No more than one acquisition per biophase were used, and biophases were determined by actual crop calendars. All sites were worked by each of four Analyst-Interpreter/Data Processing Analyst Teams who reviewed the initial processing of each segment and accepted or reworked it for an estimate of the proportion of small grains in the segment. Classification results, acquisitions and classification errors and performance results between CAMS regular and ITS rework are tabulated.
ERIC Educational Resources Information Center
Tremblay, Christopher W.
2011-01-01
College Access Marketing (CAM) is a relatively new phenomenon that seeks to positively influence the college-going rate. This report defines CAM, describes CAM examples, and discusses how CAM seeks to counter barriers to college. It explores four main elements of CAM: information, marketing, advocacy, and social mobilization. Further, it…
Complementary and alternative medicine in pulmonology.
Mark, John D; Chung, Youngran
2015-06-01
To provide a comprehensive review of complementary and alternative medicine (CAM) therapies for the treatment of pulmonary disorders in children. The use of complementary medicine (CAM) is commonly used by both children and adults with breathing problems, and especially in chronic pulmonary disorders such as asthma and cystic fibrosis. Many clinics and hospitals now offer CAM, even though most of the conventionally trained health practitioners have little knowledge or education regarding CAM therapies. Research in CAM that demonstrates overall benefit is lacking, especially in children. Often parents do not report CAM use to their child's healthcare provider and this could compromise their overall quality of care. Although many research studies evaluating CAM therapies have methodological flaws, data exist to support CAM therapies in treating children with pulmonary disorders. This review examines the latest evidence of CAM use and effectiveness in children with pulmonary disorders. Physicians should be aware of the many CAM therapy options and the research surrounding them in order to provide their patients with the most current and accurate information available.
Liow, Kore; Ablah, Elizabeth; Nguyen, John C; Sadler, Toni; Wolfe, Deborah; Tran, Ky-Dieu; Guo, Lisa; Hoang, Tina
2007-06-01
Complementary and alternative medicine (CAM) is recognized to be commonly used by patients, yet there have been few studies regarding the scope of CAM use by patients with epilepsy. This study assessed usage and perceptions of CAM by patients with epilepsy in the midwest of the United States. A 25-item survey was administered to adult patients with epilepsy, and data were collected from 228 patients. The survey collected demographics, specific CAM usage, adverse effects of CAM therapy, and perceptions of the effectiveness of CAM. Thirty-nine percent reported using CAM; 25% reported using CAM specifically for their epilepsy. Prayer/spirituality was the most commonly used form of CAM (46%), followed by "mega" vitamins (25%), chiropractic care (24%), and stress management (16%). CAM use is common among midwestern patients with epilepsy, although the pattern of use may be slightly different than in other regions of the United States and elsewhere.
Content-addressable read/write memories for image analysis
NASA Technical Reports Server (NTRS)
Snyder, W. E.; Savage, C. D.
1982-01-01
The commonly encountered image analysis problems of region labeling and clustering are found to be cases of search-and-rename problem which can be solved in parallel by a system architecture that is inherently suitable for VLSI implementation. This architecture is a novel form of content-addressable memory (CAM) which provides parallel search and update functions, allowing speed reductions down to constant time per operation. It has been proposed in related investigations by Hall (1981) that, with VLSI, CAM-based structures with enhanced instruction sets for general purpose processing will be feasible.
Marsman, Kevin; Zwickey, Heather
2009-01-01
Abstract Background Alternative medicine researchers and policy makers have classified prayer as a mind–body intervention, and thus, a modality of complementary and alternative medicine (CAM). As such, numerous epidemiological surveys of CAM utilization—which have included prayer—depict increasing CAM use, particularly in specific racial and ethnic groups. Objectives This paper discusses the implications of conflating prayer and CAM, especially regarding the definitions of both concepts and the resulting statistics of CAM utilization. PMID:19388867
Gavert, Nancy; Ben-Shmuel, Amir; Raveh, Shani; Ben-Ze'ev, Avri
2008-11-01
L1-cell adhesion molecule (L1-CAM) is a cell adhesion receptor of the immunoglobulin superfamily, known for its roles in nerve cell function. While originally believed to be present only in brain cells, in recent years L1-CAM has been detected in other tissues, and in a variety of cancer cells, including some common types of human cancer. We review the prevalence of L1-CAM in human cancer, the possible mechanisms involved in L1-CAM-mediated tumorigenesis, and cancer therapies based upon L1-CAM antibody treatment. In colon cancer cells, the L1-CAM gene was identified as a target of the Wnt/beta-catenin-TCF signaling pathway, and L1-CAM was exclusively detected at the invasive front of colon and ovarian cancer tissue. The expression of L1-CAM in normal and cancer cells enhanced tumorigenesis and conferred metastasis in colon cancer cells. Antibodies against the L1-CAM ectodomain severely inhibited the proliferation of a variety of cancer cells in culture and reduced tumor burden when injected into mice harboring cancer cells expressing L1-CAM. These results, in addition to the presence of L1-CAM on the cell surface and its restricted distribution in normal tissues, make it an ideal target for tumor therapy.
Roy, Vandana; Gupta, Monica; Ghosh, Raktim Kumar
2015-01-01
Complementary and alternative medicine (CAM) has been practiced in India for thousands of years. The aim of this study was to determine the extent of use, perception and attitude of doctors and patients utilizing the same healthcare facility. This study was conducted among 200 doctors working at a tertiary care teaching Hospital, India and 403 patients attending the same, to determine the extent of usage, attitude and perception toward CAM. The use of CAM was more among doctors (58%) when compared with the patients (28%). Among doctors, those who had utilized CAM themselves, recommended CAM as a therapy to their patients (52%) and enquired about its use from patients (37%) to a greater extent. CAM was used concomitantly with allopathic medicine by 60% patients. Very few patients (7%) were asked by their doctors about CAM use, and only 19% patients voluntarily informed their doctors about the CAM they were using. Most patients who used CAM felt it to be more effective, safer, less costly and easily available in comparison to allopathic medicines. CAM is used commonly by both doctors and patients. There is a lack of communication between doctors and patients regarding CAM, which may be improved by sensitization of doctors and inclusion of CAM in the medical curriculum.
Molecular cloning and expression of the calmodulin gene from guinea pig hearts.
Feng, Rui; Liu, Yan; Sun, Xuefei; Wang, Yan; Hu, Huiyuan; Guo, Feng; Zhao, Jinsheng; Hao, Liying
2015-06-01
The aim of the present study was to isolate and characterize a complementary DNA (cDNA) clone encoding the calmodulin (CaM; GenBank accession no. FJ012165) gene from guinea pig hearts. The CaM gene was amplified from cDNA collected from guinea pig hearts and inserted into a pGEM®-T Easy vector. Subsequently, CaM nucleotide and protein sequence similarity analysis was conducted between guinea pigs and other species. In addition, reverse transcription-polymerase chain reaction (RT-PCR) was performed to investigate the CaM 3 expression patterns in different guinea pig tissues. Sequence analysis revealed that the CaM gene isolated from the guinea pig heart had ∼90% sequence identity with the CaM 3 genes in humans, mice and rats. Furthermore, the deduced peptide sequences of CaM 3 in the guinea pig showed 100% homology to the CaM proteins from other species. In addition, the RT-PCR results indicated that CaM 3 was widely and differentially expressed in guinea pigs. In conclusion, the current study provided valuable information with regard to the cloning and expression of CaM 3 in guinea pig hearts. These findings may be helpful for understanding the function of CaM3 and the possible role of CaM3 in cardiovascular diseases.
Conacci-Sorrell, Maralice; Kaplan, Anna; Raveh, Shani; Gavert, Nancy; Sakurai, Takeshi; Ben-Ze'ev, Avri
2005-12-15
Nr-CAM, a cell-cell adhesion molecule of the immunoglobulin-like cell adhesion molecule family, known for its function in neuronal outgrowth and guidance, was recently identified as a target gene of beta-catenin signaling in human melanoma and colon carcinoma cells and tissue. Retrovirally mediated transduction of Nr-CAM into fibroblasts induces cell motility and tumorigenesis. We investigated the mechanisms by which Nr-CAM can confer properties related to tumor cell behavior and found that Nr-CAM expression in NIH3T3 cells protects cells from apoptosis in the absence of serum by constitutively activating the extracellular signal-regulated kinase and AKT signaling pathways. We detected a metalloprotease-mediated shedding of Nr-CAM into the culture medium of cells transfected with Nr-CAM, and of endogenous Nr-CAM in B16 melanoma cells. Conditioned medium and purified Nr-CAM-Fc fusion protein both enhanced cell motility, proliferation, and extracellular signal-regulated kinase and AKT activation. Moreover, Nr-CAM was found in complex with alpha4beta1 integrins in melanoma cells, indicating that it can mediate, in addition to homophilic cell-cell adhesion, heterophilic adhesion with extracellular matrix receptors. Suppression of Nr-CAM levels by small interfering RNA in B16 melanoma inhibited the adhesive and tumorigenic capacities of these cells. Stable expression of the Nr-CAM ectodomain in NIH3T3 cells conferred cell transformation and tumorigenesis in mice, suggesting that the metalloprotease-mediated shedding of Nr-CAM is a principal route for promoting oncogenesis by Nr-CAM.
The use of complementary and alternative medicines by patients with peripheral neuropathy.
Brunelli, Brian; Gorson, Kenneth C
2004-03-15
Complementary and alternative medicine (CAM) therapies have become increasingly popular and are used regularly by patients with chronic neurological disorders. The prevalence and characteristics of CAM use by patients with peripheral neuropathy is unknown. We performed a prospective, questionnaire-based study to determine the prevalence and patterns of use of CAM therapies in 180 consecutive outpatients with peripheral neuropathy. The use of CAM was reported by 77 patients (43%) with neuropathy. The most frequent were megavitamins (35%), magnets (30%), acupuncture (30%), herbal remedies (22%), and chiropractic manipulation (21%); 37 (48%) tried more than one form of alternative treatment. Seventeen respondents (27%) thought their neuropathy symptoms improved with these approaches. Those who used CAM were slightly younger (mean age 62 vs. 65 years, p = 0.05) and more often college educated (39% vs. 24%, p = 0.03) compared to CAM nonusers. They also more often reported burning neuropathic pain (62% vs. 44%, p = 0.01). Patients with diabetic neuropathy used CAM more frequently than others (p = 0.03). The most common reason for using CAM was inadequate pain control (32%). Almost half of patients did not consult a physician before starting CAM. We conclude that there is a high prevalence of CAM use in our patients with neuropathy, and one-quarter reported that their symptoms improved. CAM users were better educated than nonusers, but most did not discuss CAM treatments with their physician. Neuropathic pain was substantially more common in CAM users, and lack of pain control was the most common reason for CAM use.
Klafke, Nadja; Eliott, Jaklin A; Olver, Ian N; Wittert, Gary A
2014-05-01
Complementary and alternative medicine (CAM) is frequently used in cancer patients, often with contribution of the significant others (SOs), but without consultation of healthcare professionals. This research explored how cancer patients integrate and maintain CAM use in their everyday life, and how SOs are involved in it. In this qualitative study, male participants were selected from a preceding Australian survey on CAM use in men with cancer (94 % response rate and 86 % consent rate for follow-up interview). Semistructured interviews were conducted with 26 men and 24 SOs until data saturation was reached. Interview transcripts were coded and analyzed thematically, thereby paying close attention to participants' language in use. A major theme associated with high CAM use was "CAM routines and rituals," as it was identified that men with cancer practiced CAM as (1) functional routines, (2) meaningful rituals, and (3) mental/spiritual routines or/and rituals. Regular CAM use was associated with intrapersonal and interpersonal benefits: CAM routines provided men with certainty and control, and CAM rituals functioned for cancer patients and their SOs as a means to create meaning, thereby working to counter fear and uncertainty consequent upon a diagnosis of cancer. SOs contributed most to men's uptake and maintenance of dietary-based CAM in ritualistic form resulting in interpersonal bonding and enhanced closeness. CAM routines and rituals constitute key elements in cancer patients' regular and satisfied CAM use, and they promote familial strengthening. Clinicians and physicians can convey these benefits to patient consultations, further promoting the safe and effective use of CAM.
Yu, Kailiang; Foster, Adrianna
2016-04-01
Past studies have largely focused on hydraulic redistribution (HR) in trees, shrubs, and grasses, and recognized its role in interspecies interactions. HR in plants that conduct crassulacean acid metabolism (CAM), however, remains poorly investigated, as does the effect of HR on transpiration in different vegetation associations (i.e., tree-grass, CAM-grass, and tree-CAM associations). We have developed a mechanistic model to investigate the net direction and magnitude of HR at the patch scale for tree-grass, CAM-grass, and tree-CAM associations at the growing season to yearly timescale. The modeling results show that deep-rooted CAM plants in CAM-grass associations could perform hydraulic lift at a higher rate than trees in tree-grass associations in a relatively wet environment, as explained by a significant increase in grass transpiration rate in the shallow soil layer, balancing a lower transpiration rate by CAM plants. By comparison, trees in tree-CAM associations may perform hydraulic descent at a higher rate than those in tree-grass associations in a dry environment. Model simulations also show that hydraulic lift increases the transpiration of shallow-rooted plants, while hydraulic descent increases that of deep-rooted plants. CAM plants transpire during the night and thus perform HR during the day. Based on these model simulations, we suggest that the ability of CAM plants to perform HR at a higher rate may have different effects on the surrounding plant community than those of plants with C3 or C4 photosynthetic pathways (i.e., diurnal transpiration).
Grzywacz, Joseph G; Suerken, Cynthia K; Quandt, Sara A; Bell, Ronny A; Lang, Wei; Arcury, Thomas A
2006-06-01
To compare complementary and alternative medicine (CAM) use among adults 65 and older with and without self-reported anxiety or depression, and to investigate the prevalence and predictors of CAM use for treatment by persons with anxiety or depression. Cross-sectional survey. Computer-assisted interviews conducted in participants' homes. Subjects included 5827 adults aged 65 and older who participated in the 2002 National Health Interview Survey including the Alternative Health Supplement. None. Overall use of CAM, use of four categories of CAM, and use of 20 CAM modalities. CAM use for treatment of any health condition, and CAM use to treat mental health. Eighty-one and seven tenths percent (81.7%) of older adults with self-reported anxiety or depression who used CAM in the past year, whereas 64.6% of older adults without these conditions used CAM. Differences in CAM use were driven by elevated use of spiritual practices, relaxation techniques, and use of nonvitamin, nonmineral natural products by patients with symptoms of mental conditions. Fewer than 20% of CAM users with self-reported anxiety or depression used CAM for their mental health. Few personal and health-related factors predicted CAM use for treatment among older adults with self-reported anxiety or depression. Older adults with self-reported anxiety or depression were more likely to use spiritual practices, relaxation techniques, and nonvitamin, nonmineral natural products than elders in good mental health. However, for the majority of older adults with self-reported anxiety or depression, CAM was used for purposes other than treating mental health.
Zhou, Cheng; Penner, Joyce E.
2017-01-02
Observation-based studies have shown that the aerosol cloud lifetime effect or the increase of cloud liquid water path (LWP) with increased aerosol loading may have been overestimated in climate models. Here, we simulate shallow warm clouds on 27 May 2011 at the southern Great Plains (SGP) measurement site established by the Department of Energy's (DOE) Atmospheric Radiation Measurement (ARM) program using a single-column version of a global climate model (Community Atmosphere Model or CAM) and a cloud resolving model (CRM). The LWP simulated by CAM increases substantially with aerosol loading while that in the CRM does not. The increase of LWP inmore » CAM is caused by a large decrease of the autoconversion rate when cloud droplet number increases. In the CRM, the autoconversion rate is also reduced, but this is offset or even outweighed by the increased evaporation of cloud droplets near the cloud top, resulting in an overall decrease in LWP. Lastly, our results suggest that climate models need to include the dependence of cloud top growth and the evaporation/condensation process on cloud droplet number concentrations.« less
NASA Astrophysics Data System (ADS)
Chirayath, V.; Instrella, R.
2016-02-01
We present NASA ESTO FluidCam 1 & 2, Visible and NIR Fluid-Lensing-enabled imaging payloads for Unmanned Aerial Vehicles (UAVs). Developed as part of a focused 2014 earth science technology grant, FluidCam 1&2 are Fluid-Lensing-based computational optical imagers designed for automated 3D mapping and remote sensing of underwater coastal targets from airborne platforms. Fluid Lensing has been used to map underwater reefs in 3D in American Samoa and Hamelin Pool, Australia from UAV platforms at sub-cm scale, which has proven a valuable tool in modern marine research for marine biosphere assessment and conservation. We share FluidCam 1&2 instrument validation and testing results as well as preliminary processed data from field campaigns. Petabyte-scale aerial survey efforts using Fluid Lensing to image at-risk reefs demonstrate broad applicability to large-scale automated species identification, morphology studies and reef ecosystem characterization for shallow marine environments and terrestrial biospheres, of crucial importance to improving bathymetry data for physical oceanographic models and understanding climate change's impact on coastal zones, global oxygen production, carbon sequestration.
NASA Astrophysics Data System (ADS)
Chirayath, V.
2015-12-01
We present NASA ESTO FluidCam 1 & 2, Visible and NIR Fluid-Lensing-enabled imaging payloads for Unmanned Aerial Vehicles (UAVs). Developed as part of a focused 2014 earth science technology grant, FluidCam 1&2 are Fluid-Lensing-based computational optical imagers designed for automated 3D mapping and remote sensing of underwater coastal targets from airborne platforms. Fluid Lensing has been used to map underwater reefs in 3D in American Samoa and Hamelin Pool, Australia from UAV platforms at sub-cm scale, which has proven a valuable tool in modern marine research for marine biosphere assessment and conservation. We share FluidCam 1&2 instrument validation and testing results as well as preliminary processed data from field campaigns. Petabyte-scale aerial survey efforts using Fluid Lensing to image at-risk reefs demonstrate broad applicability to large-scale automated species identification, morphology studies and reef ecosystem characterization for shallow marine environments and terrestrial biospheres, of crucial importance to improving bathymetry data for physical oceanographic models and understanding climate change's impact on coastal zones, global oxygen production, carbon sequestration.
Color stability of CAD/CAM Zirconia ceramics following exposure to acidic and staining drinks
Colombo, Marco; Cavallo, Marco; Miegge, Matteo; Dagna, Alberto; Beltrami, Riccardo; Chiesa, Marco
2017-01-01
Background The aim of this in vitro study was to evaluate the color stability of CAD/CAM Zirconia ceramics following exposure to acidic drink (Coca Cola) and after exposure to staining solution (coffee). Material and Methods All the samples were immersed in different staining solutions over a 28-day test period. A colorimetric evaluation according to the CIE L*a*b* system was performed by a blind trained operator at 7, 14, 21, 28 days of the staining process. Shapiro Wilk test and Kruskal-Wallis ANOVA were applied to assess significant differences among restorative materials. Paired t-test was applied to test which CIE L*a*b* parameters significantly changed after immersion in staining solutions. Results One week immersion in acidic drink did not cause a perceivable discoloration for all restorative materials (ΔE < 3.3). Subsequent immersion in coffee affected color stability of all Zirconia samples, even if Kruskal-Wallis ANOVA found significant differences among the various restorative materials. Conclusions The ∆Es of CAD/CAM Zirconia ceramics after immersion in coffee varied among the products, but color integrity is not affected by contact with acidic drinks. Key words:CAD/CAM restorative materials, CIE Lab, Zirconia ceramics. PMID:29302281
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou, Cheng; Penner, Joyce E.
Observation-based studies have shown that the aerosol cloud lifetime effect or the increase of cloud liquid water path (LWP) with increased aerosol loading may have been overestimated in climate models. Here, we simulate shallow warm clouds on 27 May 2011 at the southern Great Plains (SGP) measurement site established by the Department of Energy's (DOE) Atmospheric Radiation Measurement (ARM) program using a single-column version of a global climate model (Community Atmosphere Model or CAM) and a cloud resolving model (CRM). The LWP simulated by CAM increases substantially with aerosol loading while that in the CRM does not. The increase of LWP inmore » CAM is caused by a large decrease of the autoconversion rate when cloud droplet number increases. In the CRM, the autoconversion rate is also reduced, but this is offset or even outweighed by the increased evaporation of cloud droplets near the cloud top, resulting in an overall decrease in LWP. Lastly, our results suggest that climate models need to include the dependence of cloud top growth and the evaporation/condensation process on cloud droplet number concentrations.« less
Design of Complete Dentures by Adopting CAD Developed for Fixed Prostheses.
Li, Yanfeng; Han, Weili; Cao, Jing; Iv, Yuan; Zhang, Yue; Han, Yishi; Shen, Yi; Ma, Zheng; Liu, Huanyue
2018-02-01
The demand for complete dentures is expected to increase worldwide, but complete dentures are mainly designed and fabricated manually involving a broad series of clinical and laboratory procedures. Therefore, the quality of complete dentures largely depends on the skills of the dentist and technician, leading to difficulty in quality control. Computer-aided design and manufacturing (CAD/CAM) has been used to design and fabricate various dental restorations including dental inlays, veneers, crowns, partial crowns, and fixed partial dentures (FPDs). It has been envisioned that the application of CAD/CAM technology could reduce intensive clinical/laboratory work for the fabrication of complete dentures; however, CAD/CAM is seldom used to fabricate complete dentures due to the lack of suitable CAD software to design virtual complete dentures although the CAM techniques are in a much advanced stage. Here we report the successful design of virtual complete dentures using CAD software of 3Shape Dental System 2012, which was developed for designing fixed prostheses instead of complete dentures. Our results demonstrated that complete dentures could be successfully designed by the combination of two modeling processes, single coping and full anatomical FPD, available in the 3Shape Dental System 2012. © 2016 by the American College of Prosthodontists.
Complementary, alternative, integrative, or unconventional medicine?
Penson, R T; Castro, C M; Seiden, M V; Chabner, B A; Lynch, T J
2001-01-01
Shortly before his death in 1995, Kenneth B. Schwartz, a cancer patient at Massachusetts General Hospital (MGH), founded the Kenneth B. Schwartz Center. The Schwartz Center is a non-profit organization dedicated to supporting and advancing compassionate health care delivery, which provides hope to the patient, support to caregivers, and sustenance to the healing process. The center sponsors the Schwartz Center Rounds, a monthly multidisciplinary forum where caregivers reflect on important psychosocial issues faced by patients, their families, and their caregivers, and gain insight and support from fellow staff members. Interest in complementary and alternative medicine (CAM) has grown exponentially in the past decade, fueled by Internet marketing, dissatisfaction with mainstream medicine, and a desire for patients to be actively involved in their health care. There is a large discordance between physician estimates and reported prevalence of CAM use. Many patients do not disclose their practices mainly because they believe CAM falls outside the rubric of conventional medicine or because physicians do not ask. Concern about drug interactions and adverse effects are compounded by a lack of Food and Drug Administration regulation. Physicians need to be informed about CAM and be attuned to the psychosocial needs of patients.
Color stability of CAD/CAM Zirconia ceramics following exposure to acidic and staining drinks.
Colombo, Marco; Cavallo, Marco; Miegge, Matteo; Dagna, Alberto; Beltrami, Riccardo; Chiesa, Marco; Poggio, Claudio
2017-11-01
The aim of this in vitro study was to evaluate the color stability of CAD/CAM Zirconia ceramics following exposure to acidic drink (Coca Cola) and after exposure to staining solution (coffee). All the samples were immersed in different staining solutions over a 28-day test period. A colorimetric evaluation according to the CIE L*a*b* system was performed by a blind trained operator at 7, 14, 21, 28 days of the staining process. Shapiro Wilk test and Kruskal-Wallis ANOVA were applied to assess significant differences among restorative materials. Paired t-test was applied to test which CIE L*a*b* parameters significantly changed after immersion in staining solutions. One week immersion in acidic drink did not cause a perceivable discoloration for all restorative materials (ΔE < 3.3). Subsequent immersion in coffee affected color stability of all Zirconia samples, even if Kruskal-Wallis ANOVA found significant differences among the various restorative materials. The ∆Es of CAD/CAM Zirconia ceramics after immersion in coffee varied among the products, but color integrity is not affected by contact with acidic drinks. Key words: CAD/CAM restorative materials, CIE Lab, Zirconia ceramics.
[Development of a Software for Automatically Generated Contours in Eclipse TPS].
Xie, Zhao; Hu, Jinyou; Zou, Lian; Zhang, Weisha; Zou, Yuxin; Luo, Kelin; Liu, Xiangxiang; Yu, Luxin
2015-03-01
The automatic generation of planning targets and auxiliary contours have achieved in Eclipse TPS 11.0. The scripting language autohotkey was used to develop a software for automatically generated contours in Eclipse TPS. This software is named Contour Auto Margin (CAM), which is composed of operational functions of contours, script generated visualization and script file operations. RESULTS Ten cases in different cancers have separately selected, in Eclipse TPS 11.0 scripts generated by the software could not only automatically generate contours but also do contour post-processing. For different cancers, there was no difference between automatically generated contours and manually created contours. The CAM is a user-friendly and powerful software, and can automatically generated contours fast in Eclipse TPS 11.0. With the help of CAM, it greatly save plan preparation time and improve working efficiency of radiation therapy physicists.
Arvonio, Maria Marra
2014-01-01
The use of complementary and alternative medicines (CAM) such as Reiki is on the rise in healthcare centers. Reiki is associated with a spirituality that conflicts with some belief systems. Catholic healthcare facilities are restricted from offering this therapy because it conflicts with the teachings of the Catholic Church. However, hospitals are offering it without disclosing the spiritual aspects of it to patients. This article will address the ethical concerns and possible legal implications associated with the present process of offering Reiki. It will address these concerns based on the Joint Commission's Standard of Cultural Competency and the ethical principles of autonomy and informed consent. A proposal will also be introduced identifying specific information which Reiki/CAM practitioners should offer to their patients out of respect of their autonomy as well as their cultural, spiritual, and religious beliefs. PMID:24899738
Chemical labelling for visualizing native AMPA receptors in live neurons
NASA Astrophysics Data System (ADS)
Wakayama, Sho; Kiyonaka, Shigeki; Arai, Itaru; Kakegawa, Wataru; Matsuda, Shinji; Ibata, Keiji; Nemoto, Yuri L.; Kusumi, Akihiro; Yuzaki, Michisuke; Hamachi, Itaru
2017-04-01
The location and number of neurotransmitter receptors are dynamically regulated at postsynaptic sites. However, currently available methods for visualizing receptor trafficking require the introduction of genetically engineered receptors into neurons, which can disrupt the normal functioning and processing of the original receptor. Here we report a powerful method for visualizing native α-amino-3-hydroxy-5-methyl-4-isoxazolepropionic acid (AMPA)-type glutamate receptors (AMPARs) which are essential for cognitive functions without any genetic manipulation. This is based on a covalent chemical labelling strategy driven by selective ligand-protein recognition to tether small fluorophores to AMPARs using chemical AMPAR modification (CAM) reagents. The high penetrability of CAM reagents enables visualization of native AMPARs deep in brain tissues without affecting receptor function. Moreover, CAM reagents are used to characterize the diffusion dynamics of endogenous AMPARs in both cultured neurons and hippocampal slices. This method will help clarify the involvement of AMPAR trafficking in various neuropsychiatric and neurodevelopmental disorders.
An evidence-based review of commonly used dietary supplements.
Laird, John
2015-07-01
Use of complementary and alternative medicine (CAM) is increasing in the United States. Physician assistants need to know about the efficacy of CAM therapies if they practice integrative medicine (which combines CAM and traditional therapies), recommend a CAM therapy occasionally as part of their treatment plan, refer patients to CAM providers, or have patients who self-select CAM therapies. This article describes integrative medicine and reviews the most commonly used dietary supplements.
Integrating Complementary and Alternative Medicine Education Into the Pharmacy Curriculum
Wallis, Marianne
2008-01-01
Objectives To evaluate the effectiveness of an integrated approach to the teaching of evidence-based complementary and alternative medicine (CAM) in a pharmacy curriculum. Design Evidence-based CAM education was integrated throughout the third, fourth, and fifth years of the pharmacy curriculum. Specifically, an introductory module focusing on CAM familiarization was added in the third year and integrated, evidence-based teaching related to CAM was incorporated into clinical topics through lectures and clinical case studies in the fourth and fifth years. Assessment Students' self-assessed and actual CAM knowledge increased, as did their use of evidence-based CAM resources. However, only 30% of the fourth-year students felt they had learned enough about CAM. Students preferred having CAM teaching integrated into the curriculum beginning in the first year rather than waiting until later in their education. Conclusion CAM education integrated over several years of study increases students' knowledge and application. PMID:19002274
L1-CAM and N-CAM: From Adhesion Proteins to Pharmacological Targets.
Colombo, Federico; Meldolesi, Jacopo
2015-11-01
L1 cell adhesion molecule (L1-CAM) and neural cell adhesion molecule (N-CAM), key members of the immunoglobulin-like CAM (Ig-CAM) family, were first recognized to play critical roles in surface interactions of neurons, by binding with each other and with extracellular matrix (ECM) proteins. Subsequently, adhesion was recognized to include signaling due to both activation of β-integrin, with the generation of intracellular cascades, and integration with the surface cytoskeleton. The importance of the two Ig-CAMs was revealed by their activation of the tyrosine kinase receptors of fibroblast growth factor (FGF), epidermal growth factor (EGF), and nerve growth factor (NGF). Based on these complex signaling properties, L1-CAM and N-CAM have become of great potential pharmacological interest in neurons and cancers. Treatment of neurodegenerative disorders and cognitive deficits of neurons is aimed to increase the cell Ig-CAM tone, possibly provided by synthetic/mimetic peptides. In cancer cells, where Ig-CAMs are often overexpressed, the proteins are employed for prognosis. The approaches to therapy are based on protein downregulation, antibodies, and adoptive immunotherapy. Copyright © 2015 Elsevier Ltd. All rights reserved.
Zacharias, Triantafyllos; Kulej, Katarzyna; Wang, Kevin; Torggler, Raffaela; la Cour, Jonas M.
2016-01-01
Calmodulin (CaM) is a Ca2+ binding protein modulating multiple targets, several of which are associated with cardiac pathophysiology. Recently, CaM mutations were linked to heart arrhythmia. CaM is crucial for cell growth and viability, yet the effect of the arrhythmogenic CaM mutations on cell viability, as well as heart rhythm, remains unknown, and only a few targets with relevance for heart physiology have been analyzed for their response to mutant CaM. We show that the arrhythmia-associated CaM mutants support growth and viability of DT40 cells in the absence of WT CaM except for the long QT syndrome mutant CaM D129G. Of the six CaM mutants tested (N53I, F89L, D95V, N97S, D129G, and F141L), three showed a decreased activation of Ca2+/CaM-dependent kinase II, most prominently the D129G CaM mutation, which was incapable of stimulating Thr286 autophosphorylation. Furthermore, the CaM D129G mutation led to bradycardia in zebrafish and an arrhythmic phenotype in a subset of the analyzed zebrafish. PMID:27815504
[Complementary and alternative medicine in primary care in Switzerland].
Déglon-Fischer, Agnès; Barth, Jürgen; Ausfeld-Hafter, Brigitte
2009-08-01
This study investigated the current supply of complementary and alternative medicine (CAM) in Swiss primary care. Information was collected on physicians' qualifications in CAM, frequency of patients' demand for CAM, physicians' supply and temporal resources for CAM as well as physicians' referrals to CAM. 750 (500 German-speaking and 250 French-speaking) randomly selected Swiss female and male primary care physicians were asked to complete a questionnaire (response rate 50.4%). Sociodemographic data on professional training, place of residence, and sex were used to calculate a weighting factor to correct the responders' data in the analysis accordingly. 14.2% of the physicians were qualified in at least one CAM discipline. Around 30% (95% confidence interval 25.4-34.6%) of the physicians were asked for CAM by their patients more than once a week. Homeopathy and phytotherapy were the most frequently offered therapies, followed by traditional Chinese medicine (TCM)/acupuncture. 62.5% (57.6-67.4%) of the physicians refer their patients to CAM. Most patients were referred to TCM/acupuncture. Of the 37.2% (32.6-42.4%) of the physicians who do not refer their patients to CAM, around 40% (35.1-44.9%) offer it themselves. About three quarters of the physicians offer CAM themselves or refer their patients to CAM treatments. CAM is very important in primary medical care in Switzerland. Clear regulations for CAM are required in order to ensure a high quality in care. Copyright 2009 S. Karger AG, Basel.
Complementary and alternative medicine use in patients with hematological cancers in Malaysia.
Gan, G G; Leong, Y C; Bee, P C; Chin, E; Teh, A K H
2015-08-01
Complementary and alternative medicine (CAM) is often used by cancer patients, but not many studies had been published on the prevalence of CAM use in patients with hematological cancers. This study aims to determine the prevalence of CAM and type of CAM used in this group of patients in a multiracial and multicultural country. This is a cross-sectional survey carried out in two hospitals in Malaysia. Patients with underlying hematological cancers were asked to complete the questionnaires on CAM and the Hospital Anxiety and Depression Scale. A total of 245 patients participated. The prevalence of CAM use was 70.2 %. The most common types of CAM used are biological-based therapies (90.2 %) and mind-body interventions (42 %). Vitamin and diet supplements (68.6 %) and folk/herb remedies (58 %) are the most common biological-based therapies used. There is no significant association of CAM use with age, gender, education level, and household income. Female patients are more likely to use more than one CAM therapies. The most common reason reported for CAM use was to boost immunity (57 %) and cure (24 %). Majority of patients (65 %) felt CAM was effective, and 60 % did not inform their physicians regarding CAM usage. In view of the high prevalence of CAM use in patients with hematological cancers, it is important that the physicians play an active role in seeking information from patients and to monitor possible drug-vitamin-herbal interactions.
Kessel, Kerstin A; Lettner, Sabrina; Kessel, Carmen; Bier, Henning; Biedermann, Tilo; Friess, Helmut; Herrschbach, Peter; Gschwend, Jürgen E; Meyer, Bernhard; Peschel, Christian; Schmid, Roland; Schwaiger, Markus; Wolff, Klaus-Dietrich; Combs, Stephanie E
2016-01-01
To understand if and which patients would be open-minded to Complementary and Alternative Medicine (CAM) use parallel to their oncological treatment. Moreover, we sought to determine which methods are most accepted and which are the primary motivators to use CAM. We developed and anonymously conducted a questionnaire for patients in the oncology center (TU Munich). Questions focus on different CAM methods, previous experiences, and willingness to apply or use CAM when offered in a university-based setting. A total of 171 of 376 patients (37.4% women, 62.0% men, 0.6% unknown) participated. This corresponds to a return rate of 45%. Median age was 64 years (17-87 years). Of all participants, 15.2% used CAM during their oncological therapy; 32.7% have used it in the past. The majority (81.9%) was not using CAM during therapy; 55.5% have not used CAM in the past respectively. The analysis revealed a significant correlation between education and CAM use during therapy (r = 0.18; p = 0.02), and CAM use in the past (r = 0.17; p = 0.04). Of all patients using CAM during therapy, favored methods were food supplements (42.3%), vitamins/minerals (42.3%), massage (34.6%). Motivations are especially the reduction of side effect and stress, the positive effect of certain CAM-treatments on the immune system and tumor therapy. Results showed no difference between women and men. Most patients not having had any experience with CAM complain about the deficiency of information by their treating oncologist (31.4%) as well as missing treatment possibilities (54.3%). Since many patients believe in study results demonstrating the efficacy of CAM, it stresses our task to develop innovative study protocols to investigate the outcomes of certain CAM on symptom reduction or other endpoints. Thus, prospective trials and innovative evidence-based treatment concepts to include CAM into high-end oncology is what patients demand and what a modern oncology center should offer.
1990-01-01
It has recently become clear that both extracellular matrix (ECM) glycoproteins and various cell adhesion molecules (CAMs) can promote neurite outgrowth from primary neurons, though little is known of the intracellular mechanisms through which these signals are transduced. We have previously obtained evidence that protein kinase C function is an important part of the neuronal response to laminin (Bixby, J.L. 1989. Neuron. 3:287-297). Because such CAMs as L1 (Lagenauer, C., and V. Lemmon. 1987. Proc. Natl. Acad. Sci. USA. 84:7753-7757) and N-cadherin (Bixby, J.L. and R. Zhang. 1990. J. Cell Biol. 110:1253-1260) can be purified and used as substrates to promote neurite growth, we have now tested whether the response to CAMs is similarly dependent on protein kinase C. We find that inhibition of protein kinase C inhibits growth on fibronectin or collagen as well as on laminin. In contrast, C kinase inhibition actually potentiates the initial growth response to L1 or N- cadherin. The later "phase" of outgrowth on both of these CAMs is inhibited, however. Additionally, phorbol esters, which have no effect on neurite growth when optimal laminin concentrations are used, potentiate growth even on optimal concentrations of L1 or N-cadherin. The results indicate that different intracellular mechanisms operate during initial process outgrowth on ECM substrates as compared to CAM substrates, and suggest that protein kinase C function is required for continued neurite growth on each of these glycoproteins. PMID:2277083
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-12
...: Amanda Foods (Vietnam) Ltd.; Bac Lieu Fisheries Joint Stock Company; Cadovimex Seafood Import- Export and Processing Joint Stock Company; Cafatex Fishery Joint Stock Corporation; Cam Ranh Seafoods Processing... Export Frozen Seafood Processing Joint Stock Company (``Minh Hai Jostoco''); Minh Hai Joint-Stock...
The path to CAM6: coupled simulations with CAM5.4 and CAM5.5
NASA Astrophysics Data System (ADS)
Bogenschutz, Peter A.; Gettelman, Andrew; Hannay, Cecile; Larson, Vincent E.; Neale, Richard B.; Craig, Cheryl; Chen, Chih-Chieh
2018-01-01
This paper documents coupled simulations of two developmental versions of the Community Atmosphere Model (CAM) towards CAM6. The configuration called CAM5.4 introduces new microphysics, aerosol, and ice nucleation changes, among others to CAM. The CAM5.5 configuration represents a more radical departure, as it uses an assumed probability density function (PDF)-based unified cloud parameterization to replace the turbulence, shallow convection, and warm cloud macrophysics in CAM. This assumed PDF method has been widely used in the last decade in atmosphere-only climate simulations but has never been documented in coupled mode. Here, we compare the simulated coupled climates of CAM5.4 and CAM5.5 and compare them to the control coupled simulation produced by CAM5.3. We find that CAM5.5 has lower cloud forcing biases when compared to the control simulations. Improvements are also seen in the simulated amplitude of the Niño-3.4 index, an improved representation of the diurnal cycle of precipitation, subtropical surface wind stresses, and double Intertropical Convergence Zone biases. Degradations are seen in Amazon precipitation as well as slightly colder sea surface temperatures and thinner Arctic sea ice. Simulation of the 20th century results in a credible simulation that ends slightly colder than the control coupled simulation. The authors find this is due to aerosol indirect effects that are slightly stronger in the new version of the model and propose a solution to ameliorate this. Overall, in these early coupled simulations, CAM5.5 produces a credible climate that is appropriate for science applications and is ready for integration into the National Center for Atmospheric Research's (NCAR's) next-generation climate model.
Joyce, Paul; Wardle, Jon; Zaslawski, Chris
2016-12-01
Background This paper aims to remedy a gap in the knowledge by presenting the first critical review of the literature on major themes relating to medical students perceptions and attitudes towards the exponentially growing field of complementary and alternative medicine (CAM). MethodsAfter a comprehensive database search of the literature, 21 papers were chosen as suitable for the review. The results from these papers were tabled and discussed. ResultsThe results indicated that medical students lacked knowledge of CAM and are generally positive towards CAM education (especially in the preclinical years, if it provided evidence of efficacy and post-placement). Medical students thought that CAM should generally be incorporated into the medical curriculum mainly so they can confidently undertake referral to CAM practitioners. Being able to communicate with future patients about their CAM use was a major motivation for medical students to learn about CAM and a factor for medical student support of further incorporation of CAM content in the medical curricula. Educational exposure to CAM in many forms and in many papers was shown to significantly affect medical student attitudes to CAM. This may be reflective of the fact that, outside direct CAM training, there may be limited accessible opportunities for medical students and if integration is to occur, educational exposure is most important. ConclusionsThe rise of CAM as a social and clinical phenomenon necessitates consideration of further inclusion of these topics in the medical curriculum, if future physicians are to be able to fully discharge their role as care providers in an increasingly medically pluralistic world. However, the inclusion of CAM needs to be done in an objective and critical manner, which is relevant to the learner.
Complementary and alternative medicine in breast cancer patients.
Nahleh, Zeina; Tabbara, Imad A
2003-09-01
Complementary and Alternative Medicine (CAM) is becoming increasingly popular among cancer patients, in particular those with breast cancer. It represents one of the fastest growing treatment modalities in the United States. Therefore, knowledge of CAM therapies is becoming necessary for physicians and other health care providers. CAM encompasses a wide range of modalities including special diet and nutrition, mind-body approaches, and traditional Chinese medicine. We reviewed the biomedical literature on CAM use in breast cancer patients, using Medline search from 1975 until 2002. In addition, consensus reports and books on CAM and breast cancer were included in the review. We evaluated the prevalence of CAM use in breast cancer patients, the reasons cited for its use, the different available modalities, and the reported outcomes. Use of CAM in breast cancer patients ranges between 48% and 70% in the United States. The most commonly used CAM modalities include dietary supplements, mind-body approaches, and acupuncture. The reasons cited for using CAM were to boost the immune system, improve the quality of life, prevent recurrence of cancer, provide control over life, and treat breast cancer and the side effects of treatment. Several studies reported favorable results including improved survival, better pain control, reduced anxiety, improvement in coping strategies and significant efficacy in treating nausea and vomiting. Other less well-organized trials have reported either no benefit or negative effect of CAM and potential toxicity of some commercial products. CAM is a growing field in health care and particularly among breast cancer patients. Knowledge of CAM by physicians, especially oncologists, is necessary. Oncologists should be willing to discuss the role of CAM with their patients and encourage patients to participate in well-organized research about CAM.
Freschi, Luciano; Rodrigues, Maria Aurineide; Domingues, Douglas Silva; Purgatto, Eduardo; Van Sluys, Marie-Anne; Magalhaes, Jose Ronaldo; Kaiser, Werner M.; Mercier, Helenice
2010-01-01
Genotypic, developmental, and environmental factors converge to determine the degree of Crassulacean acid metabolism (CAM) expression. To characterize the signaling events controlling CAM expression in young pineapple (Ananas comosus) plants, this photosynthetic pathway was modulated through manipulations in water availability. Rapid, intense, and completely reversible up-regulation in CAM expression was triggered by water deficit, as indicated by the rise in nocturnal malate accumulation and in the expression and activity of important CAM enzymes. During both up- and down-regulation of CAM, the degree of CAM expression was positively and negatively correlated with the endogenous levels of abscisic acid (ABA) and cytokinins, respectively. When exogenously applied, ABA stimulated and cytokinins repressed the expression of CAM. However, inhibition of water deficit-induced ABA accumulation did not block the up-regulation of CAM, suggesting that a parallel, non-ABA-dependent signaling route was also operating. Moreover, strong evidence revealed that nitric oxide (NO) may fulfill an important role during CAM signaling. Up-regulation of CAM was clearly observed in NO-treated plants, and a conspicuous temporal and spatial correlation was also evident between NO production and CAM expression. Removal of NO from the tissues either by adding NO scavenger or by inhibiting NO production significantly impaired ABA-induced up-regulation of CAM, indicating that NO likely acts as a key downstream component in the ABA-dependent signaling pathway. Finally, tungstate or glutamine inhibition of the NO-generating enzyme nitrate reductase completely blocked NO production during ABA-induced up-regulation of CAM, characterizing this enzyme as responsible for NO synthesis during CAM signaling in pineapple plants. PMID:20147491
Hovey, Liam; Fowler, C Andrew; Mahling, Ryan; Lin, Zesen; Miller, Mark Stephen; Marx, Dagan C; Yoder, Jesse B; Kim, Elaine H; Tefft, Kristin M; Waite, Brett C; Feldkamp, Michael D; Yu, Liping; Shea, Madeline A
2017-05-01
Several members of the voltage-gated sodium channel family are regulated by calmodulin (CaM) and ionic calcium. The neuronal voltage-gated sodium channel Na V 1.2 contains binding sites for both apo (calcium-depleted) and calcium-saturated CaM. We have determined equilibrium dissociation constants for rat Na V 1.2 IQ motif [IQRAYRRYLLK] binding to apo CaM (~3nM) and (Ca 2+ ) 4 -CaM (~85nM), showing that apo CaM binding is favored by 30-fold. For both apo and (Ca 2+ ) 4 -CaM, NMR demonstrated that Na V 1.2 IQ motif peptide (Na V 1.2 IQp ) exclusively made contacts with C-domain residues of CaM (CaM C ). To understand how calcium triggers conformational change at the CaM-IQ interface, we determined a solution structure (2M5E.pdb) of (Ca 2+ ) 2 -CaM C bound to Na V 1.2 IQp . The polarity of (Ca 2+ ) 2 -CaM C relative to the IQ motif was opposite to that seen in apo CaM C -Na v 1.2 IQp (2KXW), revealing that CaM C recognizes nested, anti-parallel sites in Na v 1.2 IQp . Reversal of CaM may require transient release from the IQ motif during calcium binding, and facilitate a re-orientation of CaM N allowing interactions with non-IQ Na V 1.2 residues or auxiliary regulatory proteins interacting in the vicinity of the IQ motif. Copyright © 2017 Elsevier B.V. All rights reserved.
Integrative medicine or infiltrative pseudoscience?
Li, Ben; Forbes, Thomas L; Byrne, John
2018-01-02
Evidence-based medicine, first described in 1992, offers a clear, systematic, and scientific approach to the practice of medicine. Recently, the non-evidence-based practice of complementary and alternative medicine (CAM) has been increasing in the United States and around the world, particularly at medical institutions known for providing rigorous evidence-based care. The use of CAM may cause harm to patients through interactions with evidence-based medications or if patients choose to forego evidence-based care. CAM may also put financial strain on patients as most CAM expenditures are paid out-of-pocket. Despite these drawbacks, patients continue to use CAM due to media promotion of CAM therapies, dissatisfaction with conventional healthcare, and a desire for more holistic care. Given the increasing demand for CAM, many medical institutions now offer CAM services. Recently, there has been controversy surrounding the leaders of several CAM centres based at a highly respected academic medical institution, as they publicly expressed anti-vaccination views. These controversies demonstrate the non-evidence-based philosophies that run deep within CAM that are contrary to the evidence-based care that academic medical institutions should provide. Although there are financial incentives for institutions to provide CAM, it is important to recognize that this legitimizes CAM and may cause harm to patients. The poor regulation of CAM allows for the continued distribution of products and services that have not been rigorously tested for safety and efficacy. Governments in Australia and England have successfully improved regulation of CAM and can serve as a model to other countries. Copyright © 2017 Royal College of Surgeons of Edinburgh (Scottish charity number SC005317) and Royal College of Surgeons in Ireland. Published by Elsevier Ltd. All rights reserved.
Neiberg, Rebecca H; Aickin, Mikel; Grzywacz, Joseph G; Lang, Wei; Quandt, Sara A; Bell, Ronny A; Arcury, Thomas A
2011-04-01
There are widespread assumptions that a large proportion of American adults use a variety of complementary and alternative medicine (CAM) therapies. The goal of this study is to explore the clustering or linkages among CAM categories in the general population. Linkset analysis and data from the 2002 National Health Interview Survey (NHIS) were used to address two specific aims. First, the dominant linkages of CAM categories used by the same individual were delineated, and population estimates were generated of the percentage of American adults using different linksets of CAM categories. Second, it was determined whether dominant linkages of CAM modalities differ by age, gender, ethnicity, and education. Linkset analysis, a method of estimating co-occurrence beyond chance, was used on data from the 2002 NHIS (N = 29,862) to identify possible sets of CAM use. Most adults use CAM therapies from a single category. Approximately 20% of adults combined two CAM categories, with the combination of mind-body therapies and biologically based therapies estimated to be most common. Only 5% of adults use therapies representing three or more CAM categories. Combining therapies across multiple CAM categories was more common among those 46-64, women, whites, and those with a college education. The results of this study allow researchers to refine descriptions of CAM use in the adult population. Most adults do not use a wide assortment of CAM; most use therapies within a single CAM category. Sets of CAM use were found to differ by age, gender, ethnicity, and education in ways consistent with previous research.
Women's reasons for complementary and alternative medicine use: racial/ethnic differences.
Chao, Maria T; Wade, Christine; Kronenberg, Fredi; Kalmuss, Debra; Cushman, Linda F
2006-10-01
Although racial/ethnic differences in the prevalence of complementary and alternative medicine (CAM) utilization have been documented, differences in the reasons for using CAM have not been empirically assessed. In an increasingly diverse society, understanding differences in rates of and reasons for CAM use could elucidate cultural and social factors of health behaviors and inform health care improvements. The current study examines reasons for CAM use among women in four racial/ethnic groups. A national telephone survey of 3172 women aged 18 years and older was conducted in four languages. Respondents were asked about their use of remedies or treatments not typically prescribed by a medical doctor. This study focuses on those women who used CAM in the previous year and their reasons for using CAM. Non-Hispanic white women were most likely to cite personal beliefs for CAM use. Cost of conventional medicine was most prevalent among Mexican-American women CAM users. Physician referral, family and friends, and media sources were all equally likely to lead to CAM use in non-Hispanic white women. In contrast, informal networks of family and friends were the most important social influences of CAM use among African-, Mexican-, and Chinese-American women. Racial/ethnic differences in reasons for CAM use highlight cultural and social factors that are important to consider in public evaluation of the risks and benefits of CAM remedies and treatments.
Kim, Do Yeun; Park, Wan Beom; Kang, Hee Cheol; Kim, Mi Jung; Park, Kyu-Hyun; Min, Byung-Il; Suh, Duk-Joon; Lee, Hye Won; Jung, Seung Pil; Chun, Mison; Lee, Soon Nam
2012-09-01
The current status of complementary and alternative medicine (CAM) education in Korean medical schools is still largely unknown, despite a growing need for a CAM component in medical education. The prevalence, scope, and diversity of CAM courses in Korean medical school education were evaluated. Participants included academic or curriculum deans and faculty at each of the 41 Korean medical schools. A mail survey was conducted from 2007 to 2010. Replies were received from all 41 schools. CAM was officially taught at 35 schools (85.4%), and 32 schools (91.4%) provided academic credit for CAM courses. The most common courses were introduction to CAM or integrative medicine (88.6%), traditional Korean medicine (57.1%), homeopathy and naturopathy (31.4%), and acupuncture (28.6%). Educational formats included lectures by professors and lectures and/or demonstrations by practitioners. The value order of core competencies was attitude (40/41), knowledge (32/41), and skill (6/41). Reasons for not initiating a CAM curriculum were a non-evidence-based approach in assessing the efficacy of CAM, insufficiently reliable reference resources, and insufficient time to educate students in CAM. This survey reveals heterogeneity in the content, format, and requirements among CAM courses at Korean medical schools. Korean medical school students should be instructed in CAM with a more consistent educational approach to help patients who participate in or demand CAM.
Expression of L1-CAM and ADAM10 in human colon cancer cells induces metastasis.
Gavert, Nancy; Sheffer, Michal; Raveh, Shani; Spaderna, Simone; Shtutman, Michael; Brabletz, Thomas; Barany, Francis; Paty, Phillip; Notterman, Daniel; Domany, Eytan; Ben-Ze'ev, Avri
2007-08-15
L1-CAM, a neuronal cell adhesion receptor, is also expressed in a variety of cancer cells. Recent studies identified L1-CAM as a target gene of beta-catenin-T-cell factor (TCF) signaling expressed at the invasive front of human colon cancer tissue. We found that L1-CAM expression in colon cancer cells lacking L1-CAM confers metastatic capacity, and mice injected in their spleen with such cells form liver metastases. We identified ADAM10, a metalloproteinase that cleaves the L1-CAM extracellular domain, as a novel target gene of beta-catenin-TCF signaling. ADAM10 overexpression in colon cancer cells displaying endogenous L1-CAM enhanced L1-CAM cleavage and induced liver metastasis, and ADAM10 also enhanced metastasis in colon cancer cells stably transfected with L1-CAM. DNA microarray analysis of genes induced by L1-CAM in colon cancer cells identified a cluster of genes also elevated in a large set of human colon carcinoma tissue samples. Expression of these genes in normal colon epithelium was low. These results indicate that there is a gene program induced by L1-CAM in colon cancer cells that is also present in colorectal cancer tissue and suggest that L1-CAM can serve as target for colon cancer therapy.
Women's Reasons for Complementary and Alternative Medicine Use: Racial/Ethnic Differences
CHAO, MARIA T.; WADE, CHRISTINE; KRONENBERG, FREDI; KALMUSS, DEBRA; CUSHMAN, LINDA F.
2009-01-01
Objectives Although racial/ethnic differences in the prevalence of complementary and alternative medicine (CAM) utilization have been documented, differences in the reasons for using CAM have not been empirically assessed. In an increasingly diverse society, understanding differences in rates of and reasons for CAM use could elucidate cultural and social factors of health behaviors and inform health care improvements. The current study examines reasons for CAM use among women in four racial/ethnic groups. Design A national telephone survey of 3172 women aged 18 years and older was conducted in four languages. Respondents were asked about their use of remedies or treatments not typically prescribed by a medical doctor. This study focuses on those women who used CAM in the previous year and their reasons for using CAM. Results Non-Hispanic white women were most likely to cite personal beliefs for CAM use. Cost of conventional medicine was most prevalent among Mexican-American women CAM users. Physician referral, family and friends, and media sources were all equally likely to lead to CAM use in non-Hispanic white women. In contrast, informal networks of family and friends were the most important social influences of CAM use among African-, Mexican-, and Chinese-American women. Conclusions Racial/ethnic differences in reasons for CAM use highlight cultural and social factors that are important to consider in public evaluation of the risks and benefits of CAM remedies and treatments. PMID:17034277
Complementary and alternative medicine use by Canadian university students.
Teper, Amy M; Tsai, Ellen
2008-01-01
Studies investigating Complementary and Alternative Medicine (CAM) prevalence are outdated and are generalized across different demographic groups due to their national scope. Determining trends among specific populations is necessary to gain insight into the growing popularity of CAM. To determine the prevalence and factors associated with CAM use among Canadian university undergraduate students and to determine student views regarding CAM research, education and policy-making decisions. Two arbitrarily selected undergraduate student classes at Queen's University were surveyed for this cross-sectional descriptive study. Information was provided by 128 respondents via questionnaire (75% response rate) on key demographics, CAM use and satisfaction with mainstream Canadian healthcare. Upon completion of the survey, voluntary participation was requested for the interview portion resulting in 7 semi-structured qualitative interviews. Of the 128 participants, 90 (70%) claimed to be users of at least one CAM modality. Female gender was strongly associated with CAM use (p<0.001). Other characteristics that may be correlated include being enrolled in a health-related academic program, being dissatisfied with certain aspects of the healthcare system and having parents who use CAM. The majority of respondents desired more research and education on CAM and more collaboration between the two healthcare streams. Canadian university undergraduate students are active CAM users and interest in CAM is high among this population. Further investigation is required to ensure that students are using CAM safely and appropriately.
Self-latching eccentric cam for dual stroke compressor or pump
Sisk, Francis J.
1985-01-01
For a dual capacity refrigerant compressor of the type which has an eccentric cam rotatable on a crankpin between two opposite positions which changes the total eccentricity of the crankpin and cam so as to obtain two different stroke lengths, the rotation of the cam on the crankpin being effected by a reversal of motor operation, the cam moves through an angle of about 270.degree. around the crankpin so that a centrifugal force torque tending to hold the cam in place is available at least in the reduced stroke length position of the cam, and by providing lightening cavities and eccentric weightings, the center of mass 74 of the cam can be shifted to obtain the centrifugal torque in the proper direction at both the maximum and reduced stroke positions.
Self-latching eccentric cam for dual stroke compressor or pump
Sisk, F.J.
1985-01-22
For a dual capacity refrigerant compressor of the type which has an eccentric cam rotatable on a crankpin between two opposite positions which changes the total eccentricity of the crankpin and cam so as to obtain two different stroke lengths, the rotation of the cam on the crankpin being effected by a reversal of motor operation, the cam moves through an angle of about 270[degree] around the crankpin so that a centrifugal force torque tending to hold the cam in place is available at least in the reduced stroke length position of the cam, and by providing lightening cavities and eccentric weightings, the center of mass of the cam can be shifted to obtain the centrifugal torque in the proper direction at both the maximum and reduced stroke positions. 7 figs.
Hartmann, Nicole; Neininger, Martina P; Bernhard, Matthias K; Syrbe, Steffen; Nickel, Petra; Merkenschlager, Andreas; Kiess, Wieland; Bertsche, Thilo; Bertsche, Astrid
2016-01-01
The use of complementary and alternative medicine (CAM) is popular. Parents of children suffering from epilepsy may also consider administering CAM to their children. Systematic data about frequency of and motivations for CAM use, however, are scarce. In a university hospital's neuropaediatric department parents of patients aged 0-18 years suffering from epilepsy were consecutively invited to take part in a structured interview during 4 months in 2014. Of the invited parents, 164/165 (99%) agreed to participate. From those, 21/164 (13%) stated that they used CAM in their child. The highest independent predictive value of CAM use was the occurrence of adverse drug events (ADE) of anticonvulsants as judged by parents. Patients affected by ADE had a 5.6 higher chance of receiving CAM compared to patients without ADE. Most commonly used were homeopathy (14/21, 67%) and osteopathy (12/21, 57%). The internet was the most frequently used source of information (14/21, 67%). Of the parents, 10/21 (48%) described positive effects of CAM on seizure frequency, 12/21 (57%) on general condition of their child, and 20/21 (95%) wished to continue CAM for epilepsy therapy. From the non-users of CAM, 91/143 (66%) expressed the desire to learn more about CAM for epilepsy therapy. Our study was performed in a university hospital in a large urban city in Eastern Germany. CAM user rates can differ in other parts of Germany and Europe, in other institutions and for chronic diseases other than epilepsy. The main reason for CAM use was the occurrence of ADE of anticonvulsants. More than half of the parents saw a benefit of CAM for their children. Almost all parents wished to continue CAM use, even those who did not see concrete positive effects. Copyright © 2015 European Paediatric Neurology Society. Published by Elsevier Ltd. All rights reserved.
Nachbar, Henry D.; Korytkowski, Alfred S.
1991-01-01
A grinding apparatus for grinding the interior portion of a valve stem receiving area of a valve. The apparatus comprises a faceplate, a plurality of cams mounted to an interior face of the faceplate, a locking bolt to lock the faceplate at a predetermined position on the valve, a movable grinder and a guide tube for positioning an optical viewer proximate the area to be grinded. The apparatus can either be rotated about the valve for grinding an area of the inner diameter of a valve stem receiving area or locked at a predetermined position to grind a specific point in the receiving area.
Gok Metin, Zehra; Izgu, Nur; Karadas, Canan; Arikan Donmez, Ayse
In Turkey, between 22.1% and 84.1% of patients with cancer use complementary and alternative medicine (CAM). However, few CAM-related studies have focused on the perspective of oncology nurses. This study aimed to determine the knowledge, attitudes, and practices of Turkish oncology nurses regarding CAM. A descriptive cross-sectional survey of 127 participants was conducted in Ankara, Turkey. A semistructured questionnaire including characteristics, knowledge, attitudes, and practices of oncology nurses toward CAM was administered to participants. We found that more than half of nurses (54.0%) surveyed had no information on CAM modalities. Most oncology nurses (81.1%) used audiovisual media sources to obtain CAM information. Many nurses (81.3%) reported not using any CAM in cancer care, and only 26.8% recommended CAM to patients. Most nurses used CAM to accelerate wound healing (19.7%) and to manage symptoms, including constipation and diarrhea (8.8%) and anxiety (7.9%). Music (52.8%), massage (49.6%), and exercise (48.8%) were stated to be beneficial. Important barriers to use CAM for patients with cancer involved a lack of knowledge (60.6%); needing physician approval to apply any CAM methods to patients (52.1%); legal and institutional issues (47.2%); and limited educational, training, or certificate programs (44.1%). There is a need for increased knowledge about CAM by oncology nurses, considering their vital role in symptom management of patients with cancer. This can be achieved through solving legal and institutional problems, structured and comprehensive education/training programs, and the integration of CAM therapy into cancer care guidelines.
Preventive Screening of Women Who Use Complementary and Alternative Medicine Providers
Tyree, Patrick T.; Lafferty, William E.
2009-01-01
Abstract Background Many women use complementary and alternative medicine (CAM). Although CAM use has been associated with reductions in conventionally recommended pediatric preventive care (e.g., vaccination), little is known about associations between CAM use and receipt of recommended preventive screening in women. Methods Using Washington State insurance data from 2000 to 2003, the authors generated clustered logistic regression models, examining associations between provider-based CAM use and receipt of screening tests for Chlamydia trachomatis, breast cancer, and cervical cancer: (1) contrasting women who used CAM providers only (alternative use) and women who used both conventional and CAM providers (complementary use) with women who used conventional care only and (2) testing associations between screening and use of four specific CAM provider types—naturopathic physicians, chiropractors, massage therapists, and acupuncturists. Results Both alternative and complementary use was associated with reduced Chlamydia screening. Cancer screening increased with complementary use but decreased with alternative use of CAM. Use of naturopathy was associated with decreased mammography, whereas all four CAM therapies were positively associated with Papanicolaou testing. Conclusions When used in conjunction with conventional care, use of provider-based CAM may signal high interest in various types of health-promoting behavior, including cancer screening. Negative associations between CAM and Chlamydia screening and between naturopathy and mammography require additional study. Interventions with CAM providers and their patients, aimed at improving rates of conventionally recommended screening, might encourage greater focus on preventive care, an important task when CAM providers serve as women's only contact with the healthcare system. PMID:19630554
Ebel, Marie-Desirée; Rudolph, Ivonne; Keinki, Christian; Hoppe, Andrea; Muecke, Ralph; Micke, Oliver; Muenstedt, Karsten; Huebner, Jutta
2015-08-01
A high percentage of cancer patients use complementary and alternative medicine (CAM). The aim of our study was to learn more about the association of CAM usage, information needs, perceived impact of disease, locus of control and self-efficacy of cancer patients. We asked patients attending a series of lectures on CAM using a standardized questionnaire which integrated questions on information needs, CAM and validated short questionnaires on self-efficacy, perception of the disease and locus of control of reinforcement. One hundred and eighty-five patients answered the questionnaire, from whom 45 % used CAM. Sixty percentage disclosed using CAM to the general practitioner and 57 % to the oncologist. Physicians and nurses, print media and the Internet are the most important source of information on CAM (used by 20-25 % each). Impact on neither daily life, perceived personal control nor coherence was associated with CAM usage, disclosure to physicians or sources of information. There also was no association between CAM usage and self-efficacy. In contrast, there was a significant association between CAM user rate and a high external locus of control. While CAM usage is agreed upon by many physicians due to the idea that it helps patients to become active and feel more in control of the disease, our data are in favor of the contrary. A strong perception of external locus of control seems to be a driver of CAM usage. Physicians should be aware of this association when counseling on CAM.
Belief in complementary and alternative medicine is related to age and paranormal beliefs in adults.
Van den Bulck, Jan; Custers, Kathleen
2010-04-01
The use of complementary and alternative medicine (CAM) is widespread, even among people who use conventional medicine. Positive beliefs about CAM are common among physicians and medical students. Little is known about the beliefs regarding CAM among the general public. Among science students, belief in CAM was predicted by belief in the paranormal. In a cross-sectional study, 712 randomly selected adults (>18 years old) responded to the CAM Health Belief Questionnaire (CHBQ) and a paranormal beliefs scale. CAM beliefs were very prevalent in this sample of adult Flemish men and women. Zero-order correlations indicated that belief in CAM was associated with age (r = 0.173 P < 0.001) level of education (r = -0.079 P = 0.039) social desirability (r = -0.119 P = 0.002) and paranormal belief (r = 0.365 P < 0.001). In a multivariate model, two variables predicted CAM beliefs. Support for CAM increased with age (regression coefficient: 0.01; 95% confidence interval (CI): 0.006 to 0.014), but the strongest relationship existed between support for CAM and beliefs in the paranormal. Paranormal beliefs accounted for 14% of the variance of the CAM beliefs (regression coefficient: 0.376; 95%: CI 0.30-0.44). The level of education (regression coefficient: 0.06; 95% CI: -0.014-0.129) and social desirability (regression coefficient: -0.023; 95% CI: -0.048-0.026) did not make a significant contribution to the explained variance (<0.1%, P = 0.867). Support of CAM was very prevalent in this Flemish adult population. CAM beliefs were strongly associated with paranormal beliefs.
NASA Astrophysics Data System (ADS)
Fouchet, Thierry; Wiens, Roger; Maurice, Sylvestre; Johnson, Jeffrey R.; Clegg, Samuel; Sharma, Shiv; Rull, Fernando; Montmessin, Franck; Anderson, Ryan; Beyssac, Olivier; Bonal, Lydie; Deflores, Lauren; Dromart, Gilles; Fischer, William; Forni, Olivier; Gasnault, Olivier; Grotzinger, John P.; Mangold, Nicolas; Martinez-Frias, Jesus; MacLennan, Scott; McCabe, Kevin; cais, Philippe; Nelson, Tony; Angel, Stanley; Beck, Pierre; Benzerara, Karim; Bernard, Sylvain; Bousquet, Bruno; Bridges, Nathan; Cloutis, Edward; Fabre, Cécile; Grasset, Olivier; Lanza, Nina; Lasue, Jeremie; Le Mouélic, Stéphane; Leveille, Rich; Lewin, Eric; McConnochie, Timothy H.; Melikechi, Noureddine; Meslin, Pierre-Yves; Misra, Anupam; Montagnac, Gilles; Newsom, Horton; Ollila, Ann; Pinet, Patrick; Poulet, Francois; Sobron, Pablo
2016-10-01
As chartered by the Science Definition Team, the Mars 2020 mission addresses four primary objectives: A. Characterize the processes that formed and modified the geologic record within an astrobiologically relevant ancient environment, B. Perform astrobiologically relevant investigations to determine habitability, search for materials with biosignature presentation potential, and search for evidence of past life, C. Assemble a returnable cache of samples and D. Contribute to preparation for human exploration of Mars. The SuperCam instrument, selected for the Mars 2020 rover, as a suite of four instruments, provides nested and co-aligned remote investigations: Laser Induced Breakdown Spectroscopy (LIBS), Raman spectroscopy and time-resolved fluorescence (TRF), visible and near-infrared spectroscopy (VISIR), and high resolution color imaging (RMI). SuperCam appeals broadly to the four Mars 2020 objectives.In detail, SuperCam will perform:1. Microscale mineral identification by combining LIBS elemental and VISIR mineralogical spectroscopies, especially targeting secondary minerals2. Determine the sedimental stratigraphy through color imaging and LIBS and VISIR spectroscopy3. Search for organics and bio-signatures with LIBS and Raman spectroscopy4. Quantify the volatile content of the rocks by LIBS spectroscopy to determine the degree of aquaeous alteration5. Characterize the texture of the rocks by color imaging to determine their alteration processes6. Characterize the rocks' coatings by LIBS spectroscopy7. Characterize the soil and its potential for biosignature preservation8. Monitor the odd-oxygen atmospheric chemistry.To meet these goals SuperCam will perform LIBS spectroscopy on 0.5 mm spot up to 7-meter distance, perform Raman and time-resolved fluoresence up to 12-m distance with a 0.8 mrad angular resolution, a 100 ns time gating in the 534-850 nm spectral range, acquire VISIR spectra in the range 0.4-0.85 μm with a resolution of 0.35 nm, and in the IR range over 1.3-2.6 μm, rich in mineral signatures, with a resolution of 20 nm, and provide RGB images with an angular resolution of 40 μrad over a FOV of 20 mrad.We will present the science performances of SuperCam and the forecasted operation plans.
Naja, F.; Alameddine, M.; Itani, L.; Shoaib, H.; Hariri, D.; Talhouk, S.
2015-01-01
Objective. To examine the prevalence and correlates of Complementary and Alternative Medicine (CAM) use in Lebanon. Methods. A cross-sectional survey was conducted through face to face interviews on a nationally representative sample of 1,475 Lebanese adults. The survey questionnaire explored the sociodemographic and health related characteristics as well as the types and modes of CAM use. The main outcome in this study was the use of CAM during the last 12 months. Results. Prevalence of CAM use was 29.87% with “folk herbs” being the most commonly used (75%). Two out of five CAM users indicated using it as alternative to conventional therapies and only 28.4% of users disclosed the use of CAM to their physician. CAM use was significantly associated with higher income, presence of a chronic disease, and lack of access to needed health care. Lower odds of CAM use were observed among older adults and those with a higher education level. Conclusions. This study revealed a high prevalence of CAM use in Lebanon. Health policy and decision makers need to facilitate proper regulation and integration of CAM into mainstream medicine and educate health care providers and the public alike on the safe and effective use of CAM therapies. PMID:26106436
Negotiating complementary and alternative medicine use in primary care visits with older patients
Koenig, Christopher J.; Ho, Evelyn Y.; Yadegar, Vivien; Tarn, Derjung M.
2013-01-01
Objective To empirically investigate the ways in which patients and providers discuss Complementary and Alternative Medicine (CAM) treatment in primary care visits. Methods Audio recordings from visits between 256 adult patients aged 50 years and older and 28 primary care physicians were transcribed and analyzed using discourse analysis, an empirical sociolinguistic methodology focusing on how language is used to negotiate meaning. Results Discussion about CAM occurred 128 times in 82 of 256 visits (32.0%). The most frequently discussed CAM modalities were non-vitamin, non-mineral supplements and massage. Three physician–patient interactions were analyzed turn-by-turn to demonstrate negotiations about CAM use. Patients raised CAM discussions to seek physician expertise about treatments, and physicians adopted a range of responses along a continuum that included encouragement, neutrality, and discouragement. Despite differential knowledge about CAM treatments, physicians helped patients assess the risks and benefits of CAM treatments and made recommendations based on patient preferences for treatment. Conclusion Regardless of a physician's stance or knowledge about CAM, she or he can help patients negotiate CAM treatment decisions. Practice implications Providers do not have to possess extensive knowledge about specific CAM treatments to have meaningful discussions with patients and to give patients a framework for evaluating CAM treatment use. PMID:22483672
Complementary and alternative medicine use among adults in Enugu, Nigeria.
Onyiapat, Jane-Lovena E; Okoronkwo, Ijeoma L; Ogbonnaya, Ngozi P
2011-03-04
Attention and interest in the use of Complementary and Alternative Medicine (CAM) has been reawakened globally. Evidence from studies carried out in different parts of the world has established that CAM use is very common and varies among populations. This study investigated the use of CAM among adults in Enugu urban, irrespective of their health status. It provided information on the prevalence of CAM use, forms of CAM remedies used and reasons for utilizing them The study areas were three local government areas in Enugu urban of Enugu State. Cross-sectional survey using questionnaires were administered to randomly selected households. All consenting participants were used for the study 732 participants (37.2% males and 62.8% females) were used for the study. Ages ranged from 18 - 65 years. 620 (84.7%) of the adult population have used CAM ranging from one single type to twenty different types while 112 (15.3%) have not used any form of CAM. The most commonly used CAM product was the biological products, followed by prayer/faith healing. Major reasons for using CAM include their natural state and also for health promotion and maintenance. There is need for adequate policy formulation and regulation to ensure safety and efficacy of CAM products. Measures to ensure rational use of CAM should be instituted.
Temporal and spatial transcriptomic and microRNA dynamics of CAM photosynthesis in pineapple.
Wai, Ching M; VanBuren, Robert; Zhang, Jisen; Huang, Lixian; Miao, Wenjing; Edger, Patrick P; Yim, Won C; Priest, Henry D; Meyers, Blake C; Mockler, Todd; Smith, J Andrew C; Cushman, John C; Ming, Ray
2017-10-01
The altered carbon assimilation pathway of crassulacean acid metabolism (CAM) photosynthesis results in an up to 80% higher water-use efficiency than C 3 photosynthesis in plants making it a potentially useful pathway for engineering crop plants with improved drought tolerance. Here we surveyed detailed temporal (diel time course) and spatial (across a leaf gradient) gene and microRNA (miRNA) expression patterns in the obligate CAM plant pineapple [Ananas comosus (L.) Merr.]. The high-resolution transcriptome atlas allowed us to distinguish between CAM-related and non-CAM gene copies. A differential gene co-expression network across green and white leaf diel datasets identified genes with circadian oscillation, CAM-related functions, and source-sink relations. Gene co-expression clusters containing CAM pathway genes are enriched with clock-associated cis-elements, suggesting circadian regulation of CAM. About 20% of pineapple microRNAs have diel expression patterns, with several that target key CAM-related genes. Expression and physiology data provide a model for CAM-specific carbohydrate flux and long-distance hexose transport. Together these resources provide a list of candidate genes for targeted engineering of CAM into C 3 photosynthesis crop species. © 2017 The Authors The Plant Journal © 2017 John Wiley & Sons Ltd.
Negotiating complementary and alternative medicine use in primary care visits with older patients.
Koenig, Christopher J; Ho, Evelyn Y; Yadegar, Vivien; Tarn, Derjung M
2012-12-01
To empirically investigate the ways in which patients and providers discuss Complementary and Alternative Medicine (CAM) treatment in primary care visits. Audio recordings from visits between 256 adult patients aged 50 years and older and 28 primary care physicians were transcribed and analyzed using discourse analysis, an empirical sociolinguistic methodology focusing on how language is used to negotiate meaning. Discussion about CAM occurred 128 times in 82 of 256 visits (32.0%). The most frequently discussed CAM modalities were non-vitamin, non-mineral supplements and massage. Three physician-patient interactions were analyzed turn-by-turn to demonstrate negotiations about CAM use. Patients raised CAM discussions to seek physician expertise about treatments, and physicians adopted a range of responses along a continuum that included encouragement, neutrality, and discouragement. Despite differential knowledge about CAM treatments, physicians helped patients assess the risks and benefits of CAM treatments and made recommendations based on patient preferences for treatment. Regardless of a physician's stance or knowledge about CAM, she or he can help patients negotiate CAM treatment decisions. Providers do not have to possess extensive knowledge about specific CAM treatments to have meaningful discussions with patients and to give patients a framework for evaluating CAM treatment use. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Dalla Libera, D; Colombo, B; Pavan, G; Comi, G
2014-05-01
The use of complementary alternative medicine (CAM) in paediatric populations is considerably increased, especially for pain and chronic conditions, as demonstrated by epidemiological surveys both in Europe and in the USA. In our study, CAM was used in 76 % patients of a cohort of 124 children affected by headache (age 4-16 years; 67 % female; 70 % migraine without aura, 12 % migraine with aura, 18 % tensive headache according to IHS criteria) consecutively recruited at a Pediatric Headache University Center. CAM was used as preventive treatment in 80 % cases. The main reasons for seeking CAM were: the wish of avoiding chronic use of drugs with their related side effects, the desire of an integrated approach, the reported inefficacy of conventional medicine, and a more suitable children disposition to CAM than to pharmacological compound. Female gender, younger age, migraine without aura, parents' higher educational status, maternal use of CAM and other associated chronic conditions, correlated with CAM use (p < 0.05). 73 % patients chose CAM also to treat other diseases (i.e. allergies, colitis, asthma, insomnia, muscle-scheletric disorders and dysmenorrhoea). The most assumed CAM were: herbal remedies (64 %) such as Valeriana, Ginkgo biloba, Boswellia serrata, Vitex agnus-castus, passion flower, Linden tree; vitamins/minerals supplements (40 %) with magnesium, 5-Hydroxytryptophan, vitamin B6 or B12, Multivitamin compounds; Homeopathy (47 %) with Silicea, Ignatia Amara, Pulsatilla, Aconitum, Nux Vomica, Calcarea phosphorica; physical treatment (45 %) such as Ayurvedic massage, shiatsu, osteopathy; yoga (33 %); acupuncture (11 %). CAM-often integrated with conventional care-was auto-prescribed in 30 % of the cases, suggested by non-physician in 22 %, by the General Practitioner in 24 % and by paediatrician in 24 %. Both general practitioners and neurologists were mostly unaware of their patients' CAM use. In conclusion, neurologists should inquire for CAM use and be prepared to learn about CAM therapies or to directly interact with CAM trained experts, in order to coordinate an integrative approach to health, as especially required in paediatric headache patients and their parents. Further studies are required to investigate safety and efficacy of CAM in pediatric headache, as a possible side-medicine to conventional pharmacological approach.
Abuelgasim, Khadega A; Alsharhan, Yousef; Alenzi, Tariq; Alhazzani, Abdulaziz; Ali, Yosra Z; Jazieh, Abdul Rahman
2018-03-12
A significant proportion of cancer patients use complementary and alternative medicine (CAM) along with conventional therapies (CT), whereas a smaller proportion delay or defer CT in favor of CAM. Previous studies exploring CAM use among cancer patients in the Middle East region have shown discrepant results. This study investigates the prevalence and pattern of CAM use by Saudi cancer patients. It also discusses the possible benefits and harm related to CAM use by cancer patients, and it explores the beliefs patients hold and their transparency with health care providers regarding their CAM use. A cross-sectional study was conducted in oncology wards and outpatient clinics by using face-to-face interviews with the participants. A total of 156 patients with a median age of 50 years (18-84) participated in the study. The prevalence of CAM use was 69.9%; the most prominent types of CAM were those of a religious nature, such as supplication (95.4%), Quran recitation (88.1%), consuming Zamzam water (84.4%), and water upon which the Quran has been read (63.3%). Drinking camel milk was reported by 24.1% of CAM users, whereas camel urine was consumed by 15.7%. A variety of reasons were given for CAM use: 75% reported that they were using CAM to treat cancer, enhance mood (18.3%),control pain (11.9%), enhance the immune system (11%),increase physical fitness (6.4%), and improve appetite (4.6%). Thirty percent of CAM users had discussed the issue with their doctors; only 7.7% had done so with their nurses. The use of CAM, including camel products, is highly prevalent among cancer patients in the Middle East, but these patients do not necessarily divulge their CAM use to their treating physicians and nurses. Although CAM use can be beneficial, some can be very harmful, especially for cancer patients. Association is known between camel products and brucellosis and Middle East respiratory syndrome coronavirus (MERS-CoV). Both can lead to tremendous morbidity in immune-compromised patients. Doctor-patient communication regarding CAM use is of paramount importance in cancer care.
Complementary and alternative medicine use amongst Malaysian orthopaedic oncology patients.
Dhanoa, Amreeta; Yong, Tze Lek; Yeap, Stephanie Jin Leng; Lee, Isaac Shi Zhung; Singh, Vivek Ajit
2014-10-17
Although studies have shown that a large proportion of cancer patients use CAM, no study on CAM use amongst orthopaedic oncology patients has been published. Therefore, this study aims to determine the prevalence, characteristics and factors associated with CAM use amongst orthopaedic oncology patients. All consecutive consenting patients/parents who presented at the Orthopaedic Oncology Clinic, University Malaya Medical Centre (1st January to 31st December 2013) were interviewed using a structured questionnaire. Overall, one hundred sixty-eight of the 274 patients recruited (61.3%) had used CAM at some time during their current illness. The prevalence of CAM used was 68% (123/181) for patients with malignant tumours and 48.4% (45/93) for patients with benign tumours. The most popular CAMs were biological-based therapies (90.5%), followed by mind-body techniques (40.5%). The most frequently used biological therapies were mega/multivitamins (31%), snakehead (Chana striatus) (28%) and sea cucumber (Stichopus horrens) (18%); whereas prayers (31%) and holy water (13%) dominated the mind-body category. Common reasons for CAM use were to improve physical well-being (60.1%), try out everything that would help (59.5%) and to enhance wound-healing (39.3%). Independent predictors for CAM use in multivariate analysis were paediatric patients [OR 2.46; 95% CI 0.99-6.06; p = 0.05], malignant tumours [OR 1.90; 95% CI 1.12-3.25; p = 0.018] and patients who underwent surgery [OR 2.06; 95% CI 1.15-3.69; p = 0.015]. Majority patients started taking CAMs following suggestions from family members (53%) and friends (49%). Sixty-six percent of patients felt they actually benefitted from CAM and 83.3% were satisfied/very satisfied. Only 5 patients reported side-effects. Majority of CAM users planned to continue CAM use or recommend it to others. However, only 31.5% of patients disclosed their CAM usage to their doctors. This survey revealed a high prevalence of CAM usage amongst orthopaedic oncology patients, with majority patients expressing satisfaction towards CAM. Oncologists should proactively ask patients about CAM to prevent potential adverse effects, as most patients do not share this information with them.
Wieland, L. Susan; Manheimer, Eric; Berman, Brian M.
2011-01-01
Over the past decade the Cochrane Collaboration has been an increasingly important source of information on complementary and alternative medicine (CAM) therapies. From 2007 to 2008 the Cochrane CAM Field developed a topics list that allowed us to categorize all 396 Cochrane reviews related to CAM (as of The Cochrane Library, Issue 4, 2009). This topics list is an advance in making Cochrane reviews on CAM topics accessible to the public. In this paper, we discuss challenges in developing the topics list, including developing an operational definition of CAM, deciding which reviews should be included within the CAM Field’s scope, developing the structured list of CAM Field-specific topics, and determining where in the topics list the reviews should be placed. Although aspects of our operational definition of CAM are open to revision, a standardized definition provides us with an objective, reproducible and systematic method for defining and classifying CAM therapies. PMID:21717826
Nguyen, Jannett; Liu, Michael A; Patel, Rohini J; Tahara, Keli; Nguyen, Annie L
2016-08-01
There is growing data on complementary and alternative medicine (CAM) preferences among college students. While several studies have focused on undergraduate students, there is limited data on graduate students. Cross sectional analysis of undergraduate and graduate students seeking medical care at the University of California Irvine's Student Health Center (SHC). The survey assessed previous CAM use and preferences for future CAM use and education. The majority (67.0%) had used CAM within the last year, 27.0% would use CAM for their current health condition, and 51.9% would consider CAM for their current health condition if they were more knowledgeable. Most respondents desired more CAM education and indicated that they would try CAM modalities if covered under insurance. Most college students requested more knowledge to assist in their decisions to use CAM. These findings provide insight for health centers on the preferences of college student patients. Copyright © 2016 Elsevier Ltd. All rights reserved.
Cam-Operated Pitch-Change Apparatus
NASA Technical Reports Server (NTRS)
Barnes, P. E. (Inventor)
1978-01-01
A pitch-change apparatus for a ducted thrust fan having a plurality of variable pitch blades employs a camming ring mounted coaxially at the hub at an axially fixed station along the hub axis for rotation about the hub axis both with the blades and relative to the blades. The ring has a generally spherical outer periphery and a plurality of helical camming grooves extending in a generally spherical plane on the periphery. Each of the variable pitch blades is connected to a pitch-change horn having a cam follower mounted on its outer end, and the camming ring and the horns are so arranged about the hub axis that the plurality of followers on the horns engage respectively the plurality of helical camming grooves. Rotary drive means rotates the camming ring relative to the blades to cause blade pitch to be changed through the cooperative operation of the camming grooves on the ring and the cam followers on the pitch-change horns.
Kundu, Anjana; Tassone, Rosalie F.; Jimenez, Nathalia; Seidel, Kristy; Valentine, Jessica K.; Pagel, Paul S.
2014-01-01
The authors conducted an Email survey of their medical staff to explore the attitudes, patterns of recommendation, and communication of pediatric providers about complementary and alternative medicine (CAM) in a large metropolitan children’s hospital. Two thirds of the respondents reported awareness about their patients’ CAM therapy use (65%) and recommended CAM therapy to their patients (67%). Providers who reported personal use of CAM (71%) were more likely to recommend CAM to their patients compared with those who do not (76% vs 45%; P < .05). One half of pediatric providers reported occasional consultation with their patient’s CAM provider, but bidirectional communication was rare (4%). Specific changes in care based on a CAM provider’s recommendations were also unusual (4%). Despite the positive attitudes about and willingness to recommend CAM by pediatric providers, communication between these clinicians and CAM providers may be less than ideal. PMID:21127080
Read, Suzanne C.; Carrier, Marie-Eve; Whitley, Rob; Gold, Ian; Tulandi, Togas
2014-01-01
Abstract Objectives: To explore the use of complementary and alternative medicine (CAM) for infertility in a multicultural healthcare setting and to compare Western and non-Western infertility patients' reasons for using CAM and the meanings they attribute to CAM use. Design: Qualitative semi-structured interviews using thematic analysis. Settings/location: Two infertility clinics in Montreal, Quebec, Canada. Participants: An ethnoculturally varied sample of 32 heterosexual infertile couples. Results: CAM used included lifestyle changes (e.g., changing diet, exercise), alternative medicine (e.g., acupuncture, herbal medicines), and religious methods (e.g., prayers, religious talismans). Patients expressed three attitudes toward CAM: desperate hope, casual optimism, and amused skepticism. Participants' CAM use was consistent with cultural traditions of health and fertility: Westerners relied primarily on biomedicine and used CAM mainly for relaxation, whereas non-Westerners' CAM use was often influenced by culture-specific knowledge of health, illness and fertility. Conclusions: Understanding patients' CAM use may help clinicians provide culturally sensitive, patient-centered care. PMID:25127071
Effect of gel formation on the dissolution behavior of clarithromycin tablets.
Inukai, Koki; Takiyama, Kei; Noguchi, Shuji; Iwao, Yasunori; Itai, Shigeru
2017-04-15
Clarithromycin (CAM) is a macrolide antibiotic that is widely used at clinical sites. We found that release of CAM is suppressed when tablets of CAM were exposed to an external solvent containing carboxylate buffers such as citrate. The suppressed release of CAM can be attributed to the formation of gels on the tablet surfaces, which inhibits penetration of the solvent into the tablet and thus disintegration of the tablets. Delayed disintegration of the tablets was also observed for commercial tablets. This suggests that taking CAM and carboxylates at the same time might be avoided. The crystal structure of CAM citrate reveals that molecular chains of CAM are cross-linked by hydrogen bond between citrate groups in the crystal. The crystal structure indicates that cross-linked CAM chains of the three-dimensional mesh structure might also be formed in high concentration CAM solutions in the presence of carboxylates, resulting in gel formation. Copyright © 2017 Elsevier B.V. All rights reserved.
2014-01-01
Background Patients with Type 2 Diabetes Mellitus (T2DM) are increasingly using complementary and alternative medicine (CAM) therapies due to difficulty in adhering to the therapeutic regimens and lifestyle changes necessary for disease management. Little is known about the prevalence and mode of CAM use among patients with T2DM in Lebanon. Objective To assess the prevalence and modes of CAM use among patients with T2DM residing in Beirut, Lebanon. Methods A cross-sectional survey of T2DM patients was conducted on patients recruited from two major referral centers in Beirut- a public hospital and a private academic medical center. In a face-to-face interview, participants completed a questionnaire comprised of three sections: socio-demographic, diabetes characteristics and types and modes of CAM use. Descriptive statistics, univariate and multivariate logistic regression analyses were utilized to assess the prevalence and correlates of CAM use, as well as whether the use was complementary or alternative to mainstream medicine. The main outcome in this study, CAM use, was defined as using CAM at least once since diagnosis with T2DM. Results A total of 333 T2DM patients completed the survey (response rate: 94.6%). Prevalence of CAM use since diagnosis with the disease was 38%. After adjustment, CAM use was significantly associated with a “married” status, a longer duration of T2DM, the presence of disease complications, and a positive family history of the disease. Folk foods and herbs were the most commonly used CAM followed by natural health products. One in five patients used CAM as alternative to conventional treatment. Only 7% of CAM users disclosed the CAM use to their treating physician. Health care practitioners were the least cited (7%) as influencing the choice of CAM among users. Conclusion The use of CAM therapies among T2DM patients in Lebanon is prevalent. Decision makers and care providers must fully understand the potential risks and benefits of CAM therapies to appropriately advise their patients. Attention must be dedicated to educating T2DM patients on the importance of disclosing CAM use to their physicians especially patients with a family history of diabetes, and those who have had the disease for a long time. PMID:24906634
Bahall, Mandreker
2017-06-30
Sophisticated conventional medicine (CM) has brought significant advances to cancer prevention, detection, and treatment. However, many cancer patients still turn to complementary and alternative medicine (CAM) treatment. This study explored the prevalence, patterns, and perceived value of CAM among cancer patients. This quantitative descriptive study was conducted between March 1, 2015, and July 31, 2015, among a cross-sectional, convenience sample of patients from the Oncology Department of San Fernando General Hospital in Trinidad and Tobago. Face-to-face interviews were conducted at the oncology clinic and treatment suite after obtaining informed consent. Data analysis included descriptive analysis, chi-square tests, and binary logistic regression analysis. The prevalence of CAM use among a sample of 350 cancer patients was 39.1% (39.6% for breast cancer, 44.4% for prostate cancer, 37% for ovarian cancer, and 38.7% for colon cancer patients). Herbs were the most common type of CAM used (93.4%), followed by spiritual therapy (73.7%). CAM use was more prevalent among females (68.6%), Indo-Trinidadians (63.5%), and patients aged 41-50 years (37.2%). The majority (70%-80%) rated CAM efficacy on perceived value. CAM was used mainly because of a desire to try anything that might help (67.6%), followed by it being congruent with the patients' beliefs (59.1%). Patients knew about CAM mainly through friends (69.3%) and family (69.3%). Most patients were generally satisfied (93.6%) and considered CAM helpful (89.8%), but the majority never informed their health care provider of CAM use (78.8%). Patients reported the simultaneous use of more than one type of CAM, without considering or knowing of possible side-effects. The perceived value of CAM included empowerment, control, cure, and improved quality of life. CAM use was associated with age, but no predictors of CAM use could be identified. Medicinal herbs and spiritual therapy are commonly used among cancer patients because of perceived benefits and satisfaction. CAM use is more prevalent among females, Indo-Trinidadians, and patients aged 41-50 years old. There are no useful predictors of CAM use. More than one type of CAM is commonly used simultaneously without disclosure to health care providers.
Lee, Sang-Il; Khang, Young-Ho; Lee, Moo-Song; Kang, Weechang
2002-01-01
Objectives. We compared knowledge of, attitudes toward, and experience with complementary and alternative medicine (CAM) among Western medicine–trained doctors (WMDs) and Oriental medicine–trained doctors (OMDs). Methods. In Korea, 502 WMDs and 500 OMDs were interviewed with a structured questionnaire. Results. OMDs held more favorable attitudes toward CAM than did WMDs. OMDs possessed a deeper understanding of and greater experience with CAM. OMDs more readily endorsed health beliefs congruent with CAM. Conclusions. In the future, CAM can be more readily used by OMDs than by WMDs. Because evidence for the effectiveness of CAM remains sparse, more research is needed for the prudent use of CAM in Korea. An education and training system for potential CAM providers remains to be developed. PMID:12453822
O'Reilly, Erin; Sevigny, Marika; Sabarre, Kelley-Anne; Phillips, Karen P
2014-10-14
Infertility patients are increasingly using complementary and alternative medicine (CAM) to supplement or replace conventional fertility treatments. The objective of this study was to determine the roles of CAM practitioners in the support and treatment of infertility. Ten semi-structured interviews were conducted in Ottawa, Canada in 2011 with CAM practitioners who specialized in naturopathy, acupuncture, traditional Chinese medicine, hypnotherapy and integrated medicine. CAM practitioners played an active role in both treatment and support of infertility, using a holistic, interdisciplinary and individualized approach. CAM practitioners recognized biological but also environmental and psychosomatic determinants of infertility. Participants were receptive to working with physicians, however little collaboration was described. Integrated infertility patient care through both collaboration with CAM practitioners and incorporation of CAM's holistic, individualized and interdisciplinary approaches would greatly benefit infertility patients.
McQuaid, Elizabeth L.; Fedele, David A.; Adams, Sue K.; Koinis-Mitchell, Daphne; Mitchell, Jessica; Kopel, Sheryl J.; Seifer, Ronald; Jandasek, Barbara; Fritz, Gregory K.; Canino, Glorisa
2013-01-01
Objective The current study sought to evaluate patterns of complementary and alternative medicine (CAM) use in a sample of Latino and Non-Latino white (NLW) children with asthma, to determine whether parental beliefs about conventional medications and barriers to obtaining these medications were related to CAM use, and to assess whether CAM use was associated with decreased adherence to controller medications. Methods Participants included 574 families of children with asthma from Non-Latino White, Puerto Rican, and Dominican backgrounds from RI and from Island Puerto Rico. All parents completed a brief checklist of barriers to medication use and an assessment of CAM approaches. A subsample of 259 families had controller medication use monitored objectively for approximately one month by MDILog (fluticasone propionate), TrackCap (montelukast), or dosage counter (fluticasone/salmeterol combination). Results Prevalence of CAM use was high among Latino families. Perceived barriers to obtaining medication were related to increased CAM use in Puerto Rican families from RI. Elevated medication concerns were positively associated with CAM use among NLW and Island PR families. CAM use was positively related to objective adherence within NLW families, and unrelated in other groups. Conclusions CAM use is common among Latino families with asthma. Among some families, CAM use may be initiated as a way to cope with barriers to obtaining medication or when parents have concerns about conventional medications. Families who report CAM use do not appear to be substituting CAM for conventional asthma medication. PMID:24602583
Gardiner, Paula; Filippelli, Amanda C.; Lebensohn, Patricia; Bonakdar, Robert
2013-01-01
Context Little is known about the incorporation of integrative medicine (IM) and complementary and alternative medicine (CAM) into family medicine residency programs. Objective The Society for Teachers of Family Medicine (STFM) approved a set of CAM/IM competencies for family medicine residencies. We hope to evaluate with an online survey tool, whether residency programs are implementing such competencies into their curriculum. We also hope to assess the knowledge and attitudes of Residency Directors (RDs) on the CAM/IM competencies. Design A survey was distributed by the CAFM (Council of Academic Family Medicine) Educational Research Alliance to RDs via email. The survey was distributed to 431 RDs. Of those who received it, 212 responded for a response rate of 49.1%. Questions assessed the knowledge and attitudes of CAM/IM competencies and incorporation of CAM/IM into residency curriculum. Results Forty-five percent of RDs were aware of the competencies. In term of RD attitudes, 58% reported that CAM/IM is an important component of residents' curriculum yet, 60% report not having specific learning objectives for CAM/IM in their residency curriculum. Among all programs, barriers to CAM/IM implementation included: time in residents' schedules (77%); faculty training (75%); access to CAM experts (43%); lack of reimbursement (43%), and financial resources (29%). Conclusions While many RDs are aware of the STFM CAM/IM competencies and acknowledge their role in residence education, there are many barriers preventing residencies to implementing the STFM CAM/IM competencies. PMID:24021471
Gardiner, Paula; Filippelli, Amanda C; Lebensohn, Patricia; Bonakdar, Robert
2013-01-01
Little is known about the incorporation of integrative medicine (IM) and complementary and alternative medicine (CAM) into family medicine residency programs. The Society for Teachers of Family Medicine (STFM) approved a set of CAM/IM competencies for family medicine residencies. We hope to evaluate whether residency programs are implementing such competencies into their curriculum using an online survey tool. We also hope to assess the knowledge and attitudes of Residency Directors (RDs) on the CAM/IM competencies. A survey was distributed by the Council of Academic Family Medicine (CAFM) Educational Research Alliance to RDs via e-mail. The survey was distributed to 431 RDs. Of those who received it, 212 responded, giving a response rate of 49.1%. Questions assessed the knowledge and attitudes of CAM/IM competencies and incorporation of CAM/IM into the residency curriculum. Forty-five percent of RDs were aware of the competencies. In terms of RD attitudes, 58% reported that CAM/IM is an important component of residents' curriculum; yet, 60% report not having specific learning objectives for CAM/IM in their residency curriculum. Among all programs, barriers to CAM/IM implementation included time in residents' schedules (77%); faculty training (75%); access to CAM experts (43%); lack of reimbursement (43%); and financial resources (29%). While many RDs are aware of the STFM CAM/IM competencies and acknowledge their role in residence education, there are many barriers that prevent residencies from implementing the STFM CAM/IM competencies. © 2013 Elsevier Inc. All rights reserved.
Tejada-Palacios, P; Zarratea, L; Moral, M; de la Cruz-Bértolo, J
2015-08-01
To determine the performance of RetCam vs. binocular ophthalmoscopy (BIO) in a screening program for retinopathy of prematurity (ROP). Observational comparative study with prospective data collection. Examinations with RetCam (n=169) were performed on 83 infants included in a screening program for ROP and stored for analysis at a later stage. An experienced ophthalmologist examined the ocular fundus with binocular indirect ophthalmoscopy (BIO). The RetCam images were assessed for the presence of ROP, zone, grade, and presence of plus disease. RetCam and BIO data were compared by visually to estimate sensitivity, specificity, positive (VPP) and negative (VPN) predictive values. ROP disease was detected in 108 eyes with BIO, and in 74 with RetCam. Out of 306 eyes examined with RetCam, false negative results were found in 34 eyes, with no false positives. Sensitivity of RetCam exam vs. BIO was 0.68, and specificity was 0.99. Positive predictive value was 0.93 and negative predictive value was 0.85. All 34 ROP cases not detected with RetCam were in zone III or outer zone II. They were all mild and regressed spontaneously. No threshold ROP was missed with RetCam. Binocular indirect ophthalmoscopy is the reference method for the diagnosis of ROP. RetCam may be used as an alternative for ROP screening. Copyright © 2010 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.
Conrad, A C; Muenstedt, K; Micke, O; Prott, F J; Muecke, R; Huebner, J
2014-07-01
A high proportion of cancer patients use complementary and alternative medicine (CAM). In oncology, risks of CAM are side effects and interactions. Our aim was to conduct a survey on professionals in palliative care regarding attitudes toward CAM. An internet-based survey with a standardized questionnaire was sent to all members of the German Society for Palliative Care. The questionnaire collected data on attitude toward CAM and experiences. Six hundred and ninety questionnaires (19 %) were returned (49 % physicians, 35 % nurses, 3 % psychologists). Acceptance of CAM is high (92 % for complementary and 54 % for alternative medicine). Most participants had already been asked on CAM by patients (95 %) and relatives (89 %). Forty-four percent already had used complementary methods and 5 % alternative methods. Only 21 % think themselves adequately informed. Seventy-four percent would use complementary methods in a patient with advanced tumor, and 62 % would use alternative therapy in patients if there was no other therapy. Even from those who are skeptical 45 % would treat a patient with alternative methods. In order to inform patients on CAM and to further patients' autonomy, evidence on benefits and harms of CAM must be provided. As awareness of risks from CAM is low and critical appraisal especially of alternative medicine missing, but interest on information on CAM is high, experts should provide evidence-based recommendations for CAM in palliative care to members of different professions. This could be done by a curriculum focusing on the most often used CAM methods.
Furlow, Mandi L; Patel, Divya A; Sen, Ananda; Liu, J Rebecca
2008-01-01
Background In the U.S., complementary and alternative medicine (CAM) use is most prevalent among reproductive age, educated women. We sought to determine general attitudes and approaches to CAM among obstetric and gynecology patients and physicians. Methods Obstetrician-gynecologist members of the American Medical Association in the state of Michigan and obstetric-gynecology patients at the University of Michigan were surveyed. Physician and patient attitudes and practices regarding CAM were characterized. Results Surveys were obtained from 401 physicians and 483 patients. Physicians appeared to have a more positive attitude towards CAM as compared to patients, and most reported routinely endorsing, providing or referring patients for at least one CAM modality. The most commonly used CAM interventions by patients were divergent from those rated highest among physicians, and most patients did not consult with a health care provider prior to starting CAM. Conclusion Although obstetrics/gynecology physicians and patients have a positive attitude towards CAM, physician and patients' view of the most effective CAM therapies were incongruent. Obstetrician/gynecologists should routinely ask their patients about their use of CAM with the goal of providing responsible, evidence-based advice to optimize patient care. PMID:18582380
Team, Victoria; Canaway, Rachel; Manderson, Lenore
2011-01-01
The growing evidence on the benefits and risks of complementary and alternative medicine (CAM) and its high rate of use (69% of Australians) - particularly for chronic or recurrent conditions - means increasing attention on CAM. However, few people disclose CAM use to their GP, and health professionals tend to inadequately discuss CAM-related issues with their patients, partly due to insufficient knowledge. As clinical and non-clinical chronic condition management guidelines are a means to educate primary health care practitioners, we undertook a content analysis of guidelines relevant to two common chronic conditions - cardiovascular disease (CVD) and type 2 diabetes mellitus (T2DM) - to assess their provision of CAM-related information. Ten current Australian guidelines were reviewed, revealing scant CAM content. When available, the CAM-relevant information was brief, in some cases unclear, inconclusive and lacking in direction to the GP or health care provider. Although we focus on CVD and T2DM, we argue the value of all chronic condition management guidelines integrating relevant evidence-informed information and advice on CAM risks, benefits and referrals, to increase GP awareness and knowledge of appropriate CAM therapies, and potentially to facilitate doctor-client discussion about CAM.
Hamidah, Alias; Rustam, Zainudin A; Tamil, Azmi M; Zarina, Latiff A; Zulkifli, Zakaria S; Jamal, Rahman
2009-01-01
The purpose of the current study was to determine the prevalence of use of complementary and alternative medicine (CAM) by children with cancer and to compare the characteristics of CAM users and CAM nonusers. A cross-sectional study was performed at a pediatric oncology center in Kuala Lumpur, Malaysia. The parents of 97 children with cancer were interviewed using a structured questionnaire. Overall, 84.5% of the respondents had used CAM, and most of them believed that CAM provided a boost to the immune system, and used CAM with the intention to complement conventional treatment. The most frequently used CAM was water therapy (78%), followed by spirulina (33%), vitamin C (27%), multivitamin (23%), visit to traditional healers (22%), sea cucumber (Stichopus horrens) (15%), and Chinese traditional medicine (12%). The Malay (n = 67) were using more often (93%) CAM than non-Malay (n = 30, use 67%, P = 0.001). CAM use is common among Malaysian children with cancer. Understanding the sociocultural dimension of patients' health beliefs is important to a successful treatment, and pediatric oncologists should ask for the use of CAM.
Duval, Frédéric D; Renard, Michelle; Jaquinod, Michel; Biou, Valérie; Montrichard, Françoise; Macherel, David
2002-11-01
Implication of the ubiquitous, highly conserved, Ca2+ sensor calmodulin (CaM) in pea seed germination has been investigated. Mass spectrometry analysis of purified CaM revealed the coexistence in seeds of three protein isoforms, diverging from each other by single amino acid substitution in the N-terminal alpha-helix. CaM was shown to be encoded by a small multigenic family, and full-length cDNAs of the three isoforms (PsCaM1, 2 and 3) were isolated to allow the design of specific primers in more divergent 5' and 3' untranslated regions. Expression studies, performed by semiquantitative RT-PCR, demonstrated differential expression patterns of the three transcripts during germination. PsCaM1 and 2 were detected at different levels in dry axes and cotyledons, and they accumulated during imbibition and prior to radicle protrusion. In contrast, PsCaM3 appeared only upon radicle protrusion, then gradually increased in both tissues. To characterise the biochemical properties of the CaM isoforms, functional analyses were conducted in vitro using recombinant Strep-tagged proteins (CaM1-ST, CaM2-ST and CaM3-ST) expressed in Escherichia coli. Gel mobility shift assays revealed that CaM1-ST exhibited a stoichiometric binding of a synthetic amphiphilic CaM kinase II peptide while CaM2-ST and CaM3-ST affinities for the same peptide were reduced. Affinity differences were also observed for CaM isoform binding to Trp-3, an idealised helical CaM-binding peptide. However, the three proteins activated in the same way the CaM-dependent pea NAD kinase. Finally, the significance of the single substitutions upon CaM interaction with its targets is discussed in a structural context.
Bettiol, Alessandra; Lombardi, Niccolò; Marconi, Ettore; Crescioli, Giada; Bonaiuti, Roberto; Maggini, Valentina; Gallo, Eugenia; Mugelli, Alessandro; Firenzuoli, Fabio; Ravaldi, Claudia; Vannacci, Alfredo
2018-05-16
Use of complementary and alternative medicines (CAMs) during breastfeeding is commonly increasing, mainly due to their presumed higher safety compared to conventional medications. Indeed, CAMs can cause serious adverse effects, and high-quality evidence supporting their use during lactation is limited. In Italy, specific investigations on the attitude of lactating women towards CAMs are lacking. The Herbal supplements in Breastfeeding InvesTigation (HaBIT) aimed to explore the attitudes and knowledge on CAMs among lactating women. A web-based survey was conducted over a six-year period among lactating women resident in Tuscany (Italy). Data on lactating behavior, CAMs use during pregnancy or breastfeeding, and women knowledge about CAMs' efficacy and safety were collected. 388 lactating women answered the questionnaire; the majority of them were primiparae with high education level. Two-hundred and four women declared to have been CAMs users during breastfeeding. Moreover, the 61 and 48% of subjects reported CAMs use also before and during pregnancy. A significant proportion of subjects were unable to correctly identify the type of CAMs they were using. The 73% of women were convinced that CAMs had higher or comparable safety than conventional medications; nevertheless, 65% of women admitted to have no scientific information about the potential risks of CAMs, and 14 CAMs users reported to have experienced side effects. These results claim the necessity that healthcare providers amplify their role to increase nursing women' awareness about CAMs. Further research is needed to support the evidence base of non-pharmaceutical approaches for symptom control during breastfeeding. This article is protected by copyright. All rights reserved.
Rhee, Taeho Greg; Harris, Ila M
2017-01-01
We examined whether the prevalence of complementary and alternative medicine (CAM) use varies by gender, and assessed the interaction of gender and CAM use on moderate mental distress (MMD) in U.S. adults with migraines/severe headaches. We used data from the 2012 National Health Interview Survey, which represents non-institutionalized U.S. adults with migraines/severe headaches (n = 4645 unweighted). Using a cross-sectional design with survey sampling techniques, we conducted descriptive analyses for prevalence of CAM use by gender. Multivariate logistic regression analyses were run to investigate potential roles of migraines/severe headaches and CAM use on MMD by gender. The overall prevalence of past year CAM use was 44.4%. Women consistently used CAM more frequently than men (P = .004). The most commonly used CAM types included herbal supplements (22.2%), massage (14.2%), and chiropractic/osteopathic (13.9%). After controlling for covariates, the odds of MDD were increased by the presence of migraines/severe headaches (P < .001) and the use of any CAM (P < .001). The interaction effect of migraines/severe headaches and CAM use decreased the odds of MMD by 27% in women (P < .05), but not in men. Women used CAM more frequently than men among adults with migraines/severe headaches in the United States. In addition, the interaction of gender and CAM use exists; the CAM use was associated with decreased odds of MMD among women only, suggesting that women with migraines/severe headaches may have benefited from CAM for their mental distress. Future research is needed to explore why such patterns vary by gender. © 2016 American Headache Society.
Calmodulin in complex with the first IQ motif of myosin-5a functions as an intact calcium sensor
Shen, Mei; Zhang, Ning; Zheng, Sanduo; Zhang, Wen-Bo; Zhang, Hai-Man; Lu, Zekuan; Su, Qian Peter; Sun, Yujie; Li, Xiang-dong
2016-01-01
The motor function of vertebrate myosin-5a is inhibited by its tail in a Ca2+-dependent manner. We previously demonstrated that the calmodulin (CaM) bound to the first isoleucine-glutamine (IQ) motif (IQ1) of myosin-5a is responsible for the Ca2+-dependent regulation of myosin-5a. We have solved the crystal structure of a truncated myosin-5a containing the motor domain and IQ1 (MD-IQ1) complexed with Ca2+-bound CaM (Ca2+-CaM) at 2.5-Å resolution. Compared with the structure of the MD-IQ1 complexed with essential light chain (an equivalent of apo-CaM), MD-IQ1/Ca2+-CaM displays large conformational differences in IQ1/CaM and little difference in the motor domain. In the MD-IQ1/Ca2+-CaM structure, the N-lobe and the C-lobe of Ca2+-CaM adopt an open conformation and grip the C-terminal and the N-terminal portions of the IQ1, respectively. Remarkably, the interlobe linker of CaM in IQ1/Ca2+-CaM is in a position opposite that in IQ1/apo-CaM, suggesting that CaM flip-flops relative to the IQ1 during the Ca2+ transition. We demonstrated that CaM continuously associates with the IQ1 during the Ca2+ transition and that the binding of CaM to IQ1 increases Ca2+ affinity and substantially changes the kinetics of the Ca2+ transition, suggesting that the IQ1/CaM complex functions as an intact Ca2+ sensor responding to distinct calcium signals. PMID:27647889
Solution Structure of Calmodulin Bound to the Binding Domain of the HIV-1 Matrix Protein*
Vlach, Jiri; Samal, Alexandra B.; Saad, Jamil S.
2014-01-01
Subcellular distribution of calmodulin (CaM) in human immunodeficiency virus type-1 (HIV-1)-infected cells is distinct from that observed in uninfected cells. CaM co-localizes and interacts with the HIV-1 Gag protein in the cytosol of infected cells. Although it has been shown that binding of Gag to CaM is mediated by the matrix (MA) domain, the structural details of this interaction are not known. We have recently shown that binding of CaM to MA induces a conformational change that triggers myristate exposure, and that the CaM-binding domain of MA is confined to a region spanning residues 8–43 (MA-(8–43)). Here, we present the NMR structure of CaM bound to MA-(8–43). Our data revealed that MA-(8–43), which contains a novel CaM-binding motif, binds to CaM in an antiparallel mode with the N-terminal helix (α1) anchored to the CaM C-terminal lobe, and the C-terminal helix (α2) of MA-(8–43) bound to the N-terminal lobe of CaM. The CaM protein preserves a semiextended conformation. Binding of MA-(8–43) to CaM is mediated by numerous hydrophobic interactions and stabilized by favorable electrostatic contacts. Our structural data are consistent with the findings that CaM induces unfolding of the MA protein to have access to helices α1 and α2. It is noteworthy that several MA residues involved in CaM binding have been previously implicated in membrane binding, envelope incorporation, and particle production. The present findings may ultimately help in identification of the functional role of CaM in HIV-1 replication. PMID:24500712
USE OF COMPLEMENTARY AND ALTERNATIVE MEDICINE IN GEORGIA.
Nadareishvili, I; Lunze, K; Tabagari, N; Beraia, A; Pkhakadze, G
2017-11-01
In Georgia, like in most countries globally, people commonly resort to complementary and alternative medicine (CAM). However, not much is known about CAM practices there. The aim of the study was to document common practices of CAM in Georgia and related patient attitudes. We collected data from peoples who commonly use CAM at 20 service provision centers in Georgia using cluster sampling from 300 patients. We admininstered a cross-sectional survey and conducted descriptive statistical analyses. People in Georgia use CAM either for prevention to improve general health (33%) or to treat chronic conditions (36%), spending about 25 Euros per month out of pocket. Most (77%) get their knowledge about CAM from family or friends , less than half (44%) from books or media, and 11% from medical providers. A close person's advice or experience was the most common rationale given for CAM use (54%). In our sample, 17% either don't trust or are unsatisfied with conventional medicine, 29% found CAM treatment "very effective" and 61% "quite/partially" effective; only 5% not effective. Conventional treatment was stopped in half of the cases. 35% of respondents informed their physicians of their CAM use, while about half did not. Public mistrust towards conventional medicine, CAM user high satisfaction, relatively low cost of such services in Georgia - are the factors letting us to suggest that CAM use will further increase. Frequent self taking decisions made by patients to stop physician prescribed treatment, not informing physicians on CAM use, as well as other factors put patients health at risk. Further research and capacity building in practice, education and other related aspects are needed to establish evidence-based regulation and standards for CAM in Georgia that ensure informed decision making and patient safety.
Ameade, Evans Paul Kwame; Amalba, Anthony; Helegbe, Gideon Kofi; Mohammed, Baba Sulemana
2016-07-01
Interest, use of and research into Complementary and Alternative Medicine (CAM; bǔ chōng yǔ tì dài yī xué) is on the increase in recent times even in developed countries. It may therefore be appropriate if medical students who would become future physicians possess adequate knowledge and better attitude towards CAMS. This study assessed medical students' knowledge of, attitude towards, and usage of CAM as well as their opinion about integrating CAMs into the medical curriculum. In a cross-sectional study, 203 medical students in 2nd, 3rd and 4th year classes completed a questionnaire. Data was analyzed using SPSS 18 and GraphPad 5.01. Association between different variables was tested. The overall mean knowledge score was 19.6%. Students in higher years of study were significantly more knowledgeable in CAMs (p = 0.0006). The best known CAM was herbal medicine (63.6%), with relatives and friends being their main source of information. Students' attitude towards CAM was good (75.1%) with majority (71.5%) favouring introduction of CAM into the medical curriculum; preferably at the preclinical level (67.5%). Year of study, gender and locality where student grew up did not significantly affect attitude towards CAM use. Up to 117 (59.0%) of the students had ever used CAM especially herbal medicine. Although students in this study were deficient in knowledge on CAMs, their attitude and usage was good. Herbal medicine was the best known and used CAM. Majority of the students believed knowledge on CAM would be beneficial to their practice hence, desirous of its introduction into their medical curriculum.
Song, Xuedong; Wang, Yin; Du, Hongfei; Fan, Yanru; Yang, Xue; Wang, Xiaorong; Wu, Xiaohou; Luo, Chunli
2014-07-01
HepaCAM is suppressed in a variety of human cancers, and involved in cell adhesion, growth, migration, invasion, and survival. However, the expression and function of HepaCAM in prostate cancer are still unknown. HepaCAM expression has been detected by RT-PCR, Western blotting and immunohistochemistry staining in prostate cell lines RWPE-1, LNCap, DU145, PC3, and in 75 human prostate tissue specimens, respectively. Meanwhile, the cell proliferation ability was detected by WST-8 assay. The role of HepaCAM in prostate cancer cell migration and invasion was examined by wound healing and transwell assay. And flow cytometry was used to observe the apoptosis of prostate cancer cells. Then we detected changes of Androgen Receptor translocation and ERK signaling using immunofluorescence staining and western blot after overexpression of HepaCAM. The HepaCAM expression was significantly down-regulated in prostate cancer tissues and undetected in prostate cancer cells. However, the low HepaCAM expression was not statistically associated with clinicopathological characteristics of prostate cancer. Overexpression of HepaCAM in prostate cancer cells decreased the cell proliferation, migration and invasion, and induced the cell apoptosis. Meanwhile, HepaCAM prevented the androgen receptor translocation from the cytoplasm to the nucleus and down-regulated the MAPK/ERK signaling. Our results suggested that HepaCAM acted as a tumor suppressor in prostate cancer. HepaCAM inhibited cell viability and motility which might be through suppressing the nuclear translocation of Androgen Receptor and down-regulating the ERK signaling. Therefore, it was indicated that HepaCAM may be a potential therapeutic target for prostate cancer. © 2014 Wiley Periodicals, Inc.
Ching, SiewMooi; Ramachandran, Vasudevan; Gew, Lai Teck; Lim, Sazlyna Mohd Sazlly; Sulaiman, Wan Aliaa Wan; Foo, Yoke Loong; Zakaria, Zainul Amiruddin; Samsudin, Nurul Huda; Lau, Paul Chih Ming Chih; Veettil, Sajesh K; Hoo, Fankee
2016-01-29
In Malaysia, the number of reported cases of dengue fever demonstrates an increasing trend. Since dengue fever has no vaccine or antiviral treatment available, it has become a burden. Complementary and alternative medicine (CAM) has become one of the good alternatives to treat the patients with dengue fever. There is limited study on the use of CAM among patients with dengue fever, particularly in hospital settings. This study aims to determine the prevalence, types, reasons, expenditure, and resource of information on CAM use among patients with dengue fever. This is a descriptive, cross-sectional study of 306 patients with dengue fever, which was carried out at the dengue clinic of three hospitals. Data were analysed using IBM SPSS Statistics version 21.0 and logistic regression analysis was used to determine the factors associated with CAM use. The prevalence of CAM use was 85.3% among patients with dengue fever. The most popular CAMs were isotonic drinks (85.8%), crab soup (46.7%) and papaya leaf extract (22.2%). The most common reason for CAM use was a good impression of CAM from other CAM users (33.3%). The main resource of information on CAM use among patients with dengue fever was family (54.8%). In multiple logistic regression analysis, dengue fever patients with a tertiary level are more likely to use CAM 5.8 (95% confidence interval (CI 1.62-20.45) and 3.8 (95% CI 1.12-12.93) times than secondary level and primary and below respectively. CAM was commonly used by patients with dengue fever. The predictor of CAM use was a higher level of education.
Perception and use of complementary and alternative medicine for low back pain.
Tsang, Vivian Hiu Man; Lo, Phoebe Hiu Wai; Lam, Fong Tao; Chung, Lulu Suet Wing; Tang, Tin Yan; Lui, Hoi Man; Lau, Jordan Tsz Gwan; Yee, Ho Fung; Lun, Yiu Kun; Chan, Hei Tung; Cheung, Jason Pui Yin
2017-01-01
To determine the prevalence of complementary and alternative medicine (CAM) use in patients with low back pain (LBP) and to identify its correlation with demographic factors, clinical condition and psychosocial factors. A cross-sectional study was conducted with 278 LBP patients. Use of CAM, demographic parameters and disease duration were determined. Self-reported health status and self-rated scales assessed the effect of disease on quality of life and emotional well-being, respectively. Satisfaction with orthopaedic care and belief partiality towards CAM were assessed. In all, 72.3% patients sought CAM treatment. The most common choice of CAM was traditional Chinese medicine (TCM; n = 166), followed by massage therapy ( n = 114) and chiropractic treatment ( n = 45). Within TCM, acupuncture was the most popular treatment for LBP ( n = 127). Only 32.5% patients informed their doctors of their CAM use. In univariate analyses, factors positively associated with CAM use included duration of LBP (odds ratio (OR) = 1.45, 95% confidence interval (CI): 1.06-1.97), use of CAM in close social circles (OR = 1.98, 95% CI: 1.15-3.43) and summary score for belief partiality towards CAM (OR = 1.18, 95% CI: 1.13-1.23). Variables negatively and significantly associated with status of CAM use include age (OR = 0.97, 95% CI: 0.95-0.99) and summary score for satisfaction with orthopaedic care (OR = 0.93, 95% CI: 0.88-0.99). CAM use in patients with LBP is prevalent and largely unknown to their doctors. Personal beliefs and their satisfaction with conventional medical treatment both play a part in their decisions to use CAM. Future studies may aim at understanding the effect of CAM on patient adherence to conventional medical treatment and patients' perception of well-being and pain.