Sample records for cap alpha emitters

  1. Comparison of U.S. Environmental Protection Agency’s CAP88 PC versions 3.0 and 4.0

    DOE PAGES

    Jannik, Tim; Farfan, Eduardo B.; Dixon, Ken; ...

    2015-08-01

    The Savannah River National Laboratory (SRNL) with the assistance of Georgia Regents University, completed a comparison of the U.S. Environmental Protection Agency's (EPA) environmental dosimetry code CAP88 PC V3.0 with the recently developed V4.0. CAP88 is a set of computer programs and databases used for estimation of dose and risk from radionuclide emissions to air. At the U.S. Department of Energy's Savannah River Site, CAP88 is used by SRNL for determining compliance with EPA's National Emission Standards for Hazardous Air Pollutants (40 CFR 61, Subpart H) regulations. Using standardized input parameters, individual runs were conducted for each radionuclide within itsmore » corresponding database. Some radioactive decay constants, human usage parameters, and dose coefficients changed between the two versions, directly causing a proportional change in the total effective 137Cs, 3H, 129I, 239Pu, and 90Sr) is provided. In general, the total effective doses will decrease for alpha/beta emitters because of reduced inhalation and ingestion rates in V4.0. However, for gamma emitters, such as 60Co and 137Cs, the total effective doses will increase because of changes EPA made in the external ground shine calculations.« less

  2. Comparison of U.S. Environmental Protection Agency's CAP88 PC Versions 3.0 and 4.0.

    PubMed

    Jannik, Tim; Farfan, Eduardo B; Dixon, Ken; Newton, Joseph; Sailors, Christopher; Johnson, Levi; Moore, Kelsey; Stahman, Richard

    2015-08-01

    The Savannah River National Laboratory (SRNL) with the assistance of Georgia Regents University, completed a comparison of the U.S. Environmental Protection Agency's (U.S. EPA) environmental dosimetry code CAP88 PC V3.0 with the recently developed V4.0. CAP88 is a set of computer programs and databases used for estimation of dose and risk from radionuclide emissions to air. At the U.S. Department of Energy's Savannah River Site, CAP88 is used by SRNL for determining compliance with U.S. EPA's National Emission Standards for Hazardous Air Pollutants (40 CFR 61, Subpart H) regulations. Using standardized input parameters, individual runs were conducted for each radionuclide within its corresponding database. Some radioactive decay constants, human usage parameters, and dose coefficients changed between the two versions, directly causing a proportional change in the total effective dose. A detailed summary for select radionuclides of concern at the Savannah River Site (60Co, 137Cs, 3H, 129I, 239Pu, and 90Sr) is provided. In general, the total effective doses will decrease for alpha/beta emitters because of reduced inhalation and ingestion rates in V4.0. However, for gamma emitters, such as 60Co and 137Cs, the total effective doses will increase because of changes U.S. EPA made in the external ground shine calculations.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Popp, R.A.; Lalley, P.A.; Whitney, J.B.

    A genetic polymorphism for a Bgl I endonuclease site near the ..cap alpha..-globin-like pseudogene ..cap alpha..-4 of C57BL/6 and C3H/HeN mice was used to show that ..cap alpha..-4 was not affected by three independent mutations in which the adult globin genes ..cap alpha..-1 and ..cap alpha..-2 were deleted. These results indicated that ..cap alpha..-4 might not be located adjacent to the adult ..cap alpha..-globin genes on chromosome 11. Restriction endonuclease analysis of DNA of a primary clone of a Chinese hamster-mouse somatic cell hybrid that had lost mouse chromosomes 11 and 18 showed that this clone lacked the adult murinemore » globin genes ..cap alpha..-1 and ..cap alpha..-2 but it did contain the ..cap alpha..-globin-like pseudogenes ..cap alpha..-3 and ..cap alpha..-4. These results indicated that the adult ..cap alpha..-globin genes and ..cap alpha..-globin-like pseudogenes are not located on the same chromosome. Similar analyses of several other Chinese hamster-mouse somatic cell hybrids that had segregated other mouse chromosomes indicated that the ..cap alpha..-globin-like pseudogenes ..cap alpha..-3 and ..cap alpha..-4 are located on mouse chromosomes 15 and 17, respectively. These data explain why ..cap alpha..-3 and ..cap alpha..-4 were not affected by the three independently induced deletion-type mutations that cause ..cap alpha..-thalassemia in the mouse.« less

  4. Thermophotovoltaic energy conversion system having a heavily doped n-type region

    DOEpatents

    DePoy, David M.; Charache, Greg W.; Baldasaro, Paul F.

    2000-01-01

    A thermophotovoltaic (TPV) energy conversion semiconductor device is provided which incorporates a heavily doped n-type region and which, as a consequence, has improved TPV conversion efficiency. The thermophotovoltaic energy conversion device includes an emitter layer having first and second opposed sides and a base layer in contact with the first side of the emitter layer. A highly doped n-type cap layer is formed on the second side of the emitter layer or, in another embodiment, a heavily doped n-type emitter layer takes the place of the cap layer.

  5. cap alpha. /sub i/-3 cDNA encodes the. cap alpha. subunit of G/sub k/, the stimulatory G protein of receptor-regulated K/sup +/ channels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Codina, J.; Olate, J.; Abramowitz, J.

    1988-05-15

    cDNA cloning has identified the presence in the human genome of three genes encoding ..cap alpha.. subunits of pertussis toxin substrates, generically called G/sub i/. They are named ..cap alpha../sub i/-1, ..cap alpha../sub i/-2 and ..cap alpha../sub i/-3. However, none of these genes has been functionally identified with any of the ..cap alpha.. subunits of several possible G proteins, including pertussis toxin-sensitive G/sub p/'s, stimulatory to phospholipase C or A/sub 2/, G/sub i/, inhibitory to adenylyl cyclase, or G/sub k/, stimulatory to a type of K/sup +/ channels. The authors now report the nucleotide sequence and the complete predicted aminomore » acid sequence of human liver ..cap alpha../sub i/-3 and the partial amino acid sequence of proteolytic fragments of the ..cap alpha.. subunit of human erythrocyte G/sub k/. The amino acid sequence of the proteolytic fragment is uniquely encoded by the cDNA of ..cap alpha../sub i/-3, thus identifying it as ..cap alpha../sub k/. The probable identity of ..cap alpha../sub i/-1 with ..cap alpha../sub p/ and possible roles for ..cap alpha../sub i/-2, as well as additional roles for ..cap alpha../sub i/-1 and ..cap alpha../sub i/-3 (..cap alpha../sub k/) are discussed.« less

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Popp, R.A.; Enlow, M.K.

    The clinical hematologic change in 2 groups of progeny from mice carrying radiation-induced strain SEC ..cap alpha..-chain deficiencies was found to be similar to the hematologic alterations in persons with ..cap alpha..-thalassemia. The heterozygous deletion or inactivation of the ..cap alpha..-chain gene in mice caused an anemia similar to ..cap alpha..-thalassemina minor in persons. The ..cap alpha..-chain deficiency in mice created an erythrocytosis, reticulocytosis, and microcytic, hypochromic anemia comparable with the changes in human ..cap alpha..-thalassemia minor resulting from deletion of the ..cap alpha..-chain gene. These mouse mutants are the only known animal models of human thalassemia. A comparison ofmore » hematologic values obtained from progeny possessing an ..cap alpha..-chain gene deficiency and from progeny possessing a ..beta..-chain duplication suggested that the deficiency of ..cap alpha..-chain synthesis, rather than a simple imbalance between the amounts of ..cap alpha..- and ..beta..-chains produced, was primarily responsible for the altered hematologic characteristics in these ..cap alpha..-thalassemic mice.« less

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Popp, R.A.; Bradshaw, B.S.; Hirsch, G.P.

    Embryonic hemoglobins in ..cap alpha..-thalassemic heterozygotes and normal fetuses were compared to study the effects of the deficient ..cap alpha.. chain on the synthesis of hemoglobins in the nucleated embryonic erythrocytes derived from the fetal yolk sac. Acrylamide gel electrophoresis showed that less hemoglobin Ell (..cap alpha../sub 2/y/sub 2/) was formed in ..cap alpha..-thalassemic heterozygotes between 12/sup 1///sub 2/ and 14/sup 1///sub 2/ days of gestation. Quantitation of in vitro synthesis between 11/sup 1///sub 2/ and 13/sup 1///sub 2/ days of gestation also showed that Ell was synthesized less rapidly in ..cap alpha..-thalassemic fetuses. In contrast, the synthesis of Elllmore » (..cap alpha../sub 2/z/sub 2/) was higher in ..cap alpha..-thalassemic than in normal fetuses at 12/sup 1///sub 2/ and 13/sup 1///sub 2/ days of gestation. Measurements of the synthesis of individual chains in El (x/sub 2/y/sub 2/) and Ell showed that x chain synthesis was normal and that ..cap alpha.. chain synthesis was deficient in ..cap alpha..-thalassemic fetuses at 11/sup 1///sub 2/ and 12/sup 1///sub 2/ days of gestation. Thus, there is still no proof for close linkage of x- and ..cap alpha..-chain genes in chromosome 11. Differences in the electrophoretic patterns of embryonic hemoglobins of ..cap alpha..-thalassemic and normal fetuses can be explained by normal synthesis of x chains, deficient synthesis of ..cap alpha.. chains, and a higher affinity of z than y for the reduced amount of ..cap alpha.. chain present in the nucleated embryonic erythrocytes of ..cap alpha..-thalassemic mice.« less

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Popp, R.A.; Bradshaw, B.S.; Hirsch, G.P.

    Embryonic hemoglobins in heterozygous ..cap alpha..-thalassemic and normal fetuses were compared to study the effects of the deficient ..cap alpha.. chain on the synthesis of hemoglobins in the nucleated embryonic erythrocytes derived from the fetal yolk sac. Visual inspection of embryonic hemoglobins following acrylamide gel electrophoresis suggested that less hemoglobin EII (..cap alpha../sub 2/y/sub 2/) was formed in ..cap alpha..-thalassemic heterozygotes between 12/sup 1///sub 2/ and 14/sup 1///sub 2/ days of gestation. Quantitation of in vitro synthesis between 11/sup 1///sub 2/ and 13/sup 1///sub 2/ days of gestation confirmed that EII was synthesized less rapidly in ..cap alpha..-thalassemic fetuses. Inmore » contrast, the synthesis of EIII (..cap alpha../sub 2/z/sub 2/) was higher in ..cap alpha..-thalassemic than in normal fetuses at 12/sup 1///sub 2/ and 13/sup 1///sub 2/ days of gestation. Measurements of synthesis of individual chains in EI (x/sub 2/y/sub 2/) and EII showed that x-chain synthesis was normal and that ..cap alpha..-chain synthesis was deficient in ..cap alpha..-thalassemic fetuses at 11/sup 1///sub 2/ and 12/sup 1///sub 2/ days of gestation. There is still no proof for close linkage of x- and ..cap alpha..-chain genes in chromosome 11. Differences in the electrophoretic patterns of embryonic hemoglobins of ..cap alpha..-thalassemic and normal fetuses can be explained by normal synthesis of x chains, deficient synthesis of ..cap alpha.. chains, and a higher affinity of z than y for the reduced amount of ..cap alpha.. chain present in the nucleated embryonic erythrocytes of ..cap alpha..-thalassemic mice.« less

  9. Variations in the concentration of plutonium, strontium-90 and total alpha-emitters in human teeth collected within the British Isles.

    PubMed

    O'Donnell, R G; Mitchell, P I; Priest, N D; Strange, L; Fox, A; Henshaw, D L; Long, S C

    1997-08-18

    Concentrations of plutonium-239, plutonium-240, strontium-90 and total alpha-emitters have been measured in children's teeth collected throughout Great Britain and Ireland. The concentrations of plutonium and strontium-90 were measured in batched samples, each containing approximately 50 teeth, using low-background radiochemical methods. The concentrations of total alpha-emitters were determined in single teeth using alpha-sensitive plastic track detectors. The results showed that the average concentrations of total alpha-emitters and strontium-90 were approximately one to three orders of magnitude greater than the equivalent concentrations of plutonium-239,240. Regression analyses indicated that the concentrations of plutonium, but not strontium-90 or total alpha-emitters, decreased with increasing distance from the Sellafield nuclear fuel reprocessing plant-suggesting that this plant is a source of plutonium contamination in the wider population of the British Isles. Nevertheless, the measured absolute concentrations of plutonium (mean = 5 +/- 4 mBq kg-1 ash wt.) were so low that they are considered to present an insignificant radiological hazard.

  10. Synthetic. cap alpha. subunit peptide 125-147 of human nicotinic acetylcholine receptor induces antibodies to native receptor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCormick, D.J.; Griesmann, G.E.; Huang, Z.

    1986-03-05

    A synthetic peptide corresponding to residues 125-147 of the Torpedo acetylcholine receptor (AChR) ..cap alpha.. subunit proved to be a major antigenic region of the AChR. Rats inoculated with 50 ..mu..g of peptide (T ..cap alpha.. 125-147) developed T cell immunity and antibodies to native AChR and signs of experimental autoimmune myasthenia gravis. They report the synthesis and preliminary testing of a disulfide-looped peptide comprising residues 125-147 of the human AChR ..cap alpha.. subunit. Peptide H ..cap alpha.. 125-147 differs from T ..cap alpha.. 125-147 at residues 139 (Glu for Gln) and 143 (Ser for Thr). In immunoprecipitation assays, antibodiesmore » to Torpedo AChR bound /sup 125/I-labelled H..cap alpha.. 125-147 antibody bound H..cap alpha.. 125-147, but monoclonal antibodies to an immunodominant region of native AChR bound neither H..cap alpha.. 125-147 nor T ..cap alpha.. 125-147. Rats immunized with H ..cap alpha.. 125-147 produced anti-mammalian muscle AChR antibodies that induced modulation of AChRs from cultured human myotubes. Thus, region 125-147 of the human AChR ..cap alpha.. subunit is extracellular in muscle, and is both antigenic and immunogenic. It remains to be determined whether or not autoantibodies to this region may in part cause the weakness or myasthenia gravis in man.« less

  11. Simultaneous determination of specific alpha and beta emitters by LSC-PLS in water samples.

    PubMed

    Fons-Castells, J; Tent-Petrus, J; Llauradó, M

    2017-01-01

    Liquid scintillation counting (LSC) is a commonly used technique for the determination of alpha and beta emitters. However, LSC has poor resolution and the continuous spectra for beta emitters hinder the simultaneous determination of several alpha and beta emitters from the same spectrum. In this paper, the feasibility of multivariate calibration by partial least squares (PLS) models for the determination of several alpha ( nat U, 241 Am and 226 Ra) and beta emitters ( 40 K, 60 Co, 90 Sr/ 90 Y, 134 Cs and 137 Cs) in water samples is reported. A set of alpha and beta spectra from radionuclide calibration standards were used to construct three PLS models. Experimentally mixed radionuclides and intercomparision materials were used to validate the models. The results had a maximum relative bias of 25% when all the radionuclides in the sample were included in the calibration set; otherwise the relative bias was over 100% for some radionuclides. The results obtained show that LSC-PLS is a useful approach for the simultaneous determination of alpha and beta emitters in multi-radionuclide samples. However, to obtain useful results, it is important to include all the radionuclides expected in the studied scenario in the calibration set. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Activity and subcellular compartmentalization of peroxisome proliferator-activated receptor alpha are altered by the centrosome-associated protein CAP350.

    PubMed

    Patel, Hansa; Truant, Ray; Rachubinski, Richard A; Capone, John P

    2005-01-01

    Peroxisome proliferator-activated nuclear hormone receptors (PPAR) are ligand-activated transcription factors that play pivotal roles in governing metabolic homeostasis and cell growth. PPARs are primarily in the nucleus but, under certain circumstances, can be found in the cytoplasm. We show here that PPAR(alpha) interacts with the centrosome-associated protein CAP350. CAP350 also interacts with PPAR(delta), PPAR(gamma) and liver-X-receptor alpha, but not with the 9-cis retinoic acid receptor, RXR(alpha). Immunofluorescence analysis indicated that PPAR(alpha) is diffusely distributed in the nucleus and excluded from the cytoplasm. However, in the presence of coexpressed CAP350, PPAR(alpha) colocalizes with CAP350 to discrete nuclear foci and to the centrosome, perinuclear region and intermediate filaments. In contrast, the subcellular distribution of RXR(alpha) or of thyroid hormone receptor alpha was not altered by coexpression of CAP350. An amino-terminal fragment of CAP350 was localized exclusively to nuclear foci and was sufficient to recruit PPAR(alpha) to these sites. Mutation of the single putative nuclear hormone receptor interacting signature motif LXXLL present in this fragment had no effect on its subnuclear localization but abrogated recruitment of PPAR(alpha) to nuclear foci. Surprisingly, mutation of the LXXLL motif in this CAP350 subfragment did not prevent its binding to PPAR(alpha) in vitro, suggesting that this motif serves some function other than PPAR(alpha) binding in recruiting PPAR(alpha) to nuclear spots. CAP350 inhibited PPAR(alpha)-mediated transactivation in an LXXLL-dependent manner, suggesting that CAP350 represses PPAR(alpha) function. Our findings implicate CAP350 in a dynamic process that recruits PPAR(alpha) to discrete nuclear and cytoplasmic compartments and suggest that altered intracellular compartmentalization represents a regulatory process that modulates PPAR function.

  13. Functional properties of an isolated. cap alpha beta. heterodimeric human placenta insulin-like growth factor 1 receptor complex

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feltz, S.M.; Swanson, M.L.; Wemmie, J.A.

    1988-05-03

    Treatment of human placenta membranes at pH 8.5 in the presence of 2.0 mM dithiothreitol (DTT) for 5 min, followed by the simultaneous removal of the DTT and pH adjustment of pH 7.6, resulted in the formation of a functional ..cap alpha beta.. heterodimeric insulin-like growth factor 1 (IGF-1) receptor complex from the native ..cap alpha../sub 2/..beta../sub 2/ heterotetrameric disulfide-linked state. The membrane-bound ..cap alpha beta.. heterodimeric complex displayed similar curvilinear /sup 125/I-IGF-1 equilibrium binding compared to the ..cap alpha../sub 2/..beta../sub 2/ heterotetrameric complex. /sup 125/I-IGF-1 binding to both the isolated ..cap alpha../sub 2/..beta../sub 2/ heterotetrameric and ..cap alpha beta..more » heterodimeric complexes demonstrated a marked straightening of the Scatchard plots, compared to the placenta membrane-bound IGF-1 receptors, with a 2-fold increase in the high-affinity binding component. IGF-1 stimulation of IGF-1 receptor autophosphorylation indicated that the ligand-dependent activation of ..cap alpha beta.. heterodimeric protein kinase activity occurred concomitant with the reassociation into a covalent ..cap alpha../sub 2/..beta../sub 2/ heterotetrameric state. These data demonstrate that (i) a combination of alkaline pH and DTT treatment of human placenta membranes results in the formation of an ..cap alpha beta.. heterodimeric IGF-1 receptor complex, (ii) unlike the insulin receptor, high-affinity homogeneous IGF-1 binding occurs in both the ..cap alpha../sub 2/..beta../sub 2/ heterotetrameric and ..cap alpha beta.. heterodimeric complexes, and (iii) IGF-1-dependent autophosphorylation of the ..cap alpha beta.. heterodimeric IGF-1 receptor complex correlates wit an IGF-1 dependent covalent reassociation into an ..cap alpha../sub 2/..beta../sub 2/ heterotetrameric disulfide-linked state.« less

  14. Kinetics of ozonation. 4. Reactions of ozone with. cap alpha. -tocopherol and oleate and linoleate esters in carbon tetrachloride and in aqueous micellar solvents

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Giamalva, D.H.; Church, D.F.; Pryor, W.A.

    1986-10-15

    Vitamin E (..cap alpha..-tocopherol; ..cap alpha..-T) is known to protect animals against the deleterious effects of ozone in polluted air; one such effect is the ozone-initiated autooxidation of polyunsaturated fatty acids (PUFA) that occur in membranes. In order to assess the possibility of a direct reaction of ozone with ..cap alpha..-T competing with the very fast ozone-PUFA reaction, we have measured the rates of reaction of ozone with ..cap alpha..-T, oleic acid, and linoleic acid. I CCl/sub 4/ as solvent, ..cap alpha..-T reacts with ozone with a rate constant of about 5500 M/sup -1/ s/sup -1/; methyl oleate and methylmore » linoleate react 2 orders of magnitude faster. In aqueous micellar solutions the rate constants for ..cap alpha..-T and the fatty acids are more similar. The k for the ozone/..cap alpha..-T reaction is about 1 x 10/sup 6/ M/sup -1/ s/sup -1/ at pH 7, but decreases as the solution becomes more acidic; the k's for oleic acid and linoleic acid are ca. 1 x 10/sup 6/ M/sup -1/ s/sup -1/ and exhibit no significant pH dependence. Since the ratio of fatty acids to ..cap alpha..-T in membranes is typically at least 100-1000 to 1, we conclude that the direct reaction of ozone with ..cap alpha..-T is unlikely. Thus, the protection that vitamin E provides to animals breathing ozone-containing air must result from vitamin E acting as a free radical scavenger. We have also detected the ..cap alpha..-tocopheroxyl radical as an intermediate from the reaction of ozone with ..cap alpha..-T both in CCl/sub 4/ and aqueous micelles using electron spin resonance spectroscopy. The authors suggest that the observation of this intermediate is consistent with an initial electron transfer from ..cap alpha..-T to ozone.« less

  15. Emittance Theory for Cylindrical Fiber Selective Emitter

    NASA Technical Reports Server (NTRS)

    Chubb, Donald L.

    1998-01-01

    A fibrous rare earth selective emitter is approximated as an infinitely long cylinder. The spectral emittance, epsilon(lambda), is obtained by solving the radiative transfer equations with appropriate boundary conditions and uniform temperature. For optical depths, Kappa(R) = alpha(lambda)R, where alpha(lambda) is the extinction coefficient and R is the cylinder radius, greater than 1 the spectral emittance is nearly at its maximum value. There is an optimum cylinder radius, R(opt), for maximum emitter efficiency, eta(E). Values for R(opt) are strongly dependent on the number of emission bands of the material. The optimum radius decreases slowly with increasing emitter temperature, while the maximum efficiency and useful radiated power increase rapidly with increasing temperature.

  16. Identification of a GTP-binding protein. cap alpha. subunit that lacks an apparent ADP-ribosylation site for pertussis toxin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fong, H.K.W.; Yoshimoto, K.K.; Eversole-Cire, P.

    1988-05-01

    Recent molecular cloning of cDNA for the ..cap alpha.. subunit of bovine transducin (a guanine nucleotide-binding regulatory protein, or G protein) has revealed the presence of two retinal-specific transducins, called T/sub r/ and T/sub c/, which are expressed in rod or cone photoreceptor cells. In a further study of G-protein diversity and signal transduction in the retina, the authors have identified a G-protein ..cap alpha.. subunit, which they refer to as G/sub z/..cap alpha.., by isolating a human retinal cDNA clone that cross-hybridizes at reduced stringency with bovine T/sub r/ ..cap alpha..-subunit cDNA. The deduced amino acid sequence of G/submore » z/..cap alpha.. is 41-67% identical with those of other known G-protein ..cap alpha.. subunits. However, the 355-residue G/sub z/..cap alpha.. lacks a consensus site for ADP-ribosylation by pertussis toxin, and its amino acid sequence varies within a number of regions that are strongly conserved among all of the other G-protein ..cap alpha.. subunits. They suggest that G/sub z/..cap alpha.., which appears to be highly expressed in neural tissues, represents a member of a subfamily of G proteins that mediate signal transduction in pertussis toxin-insensitive systems.« less

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martinell, J.; Whitney, J.B.; Popp, R.A.

    Three types of mice with globin gene mutations, called 352HB, 27HB, and Hba/sup th-J/, appear to be true animal models of human thalassemia. Expression of the ..cap alpha..-globin genes in three stocks of mice, each one heterozygous for one of the ..cap alpha..-globin mutations, was examined at the polypeptide, RNA, and DNA levels. ..cap alpha..-globin polypeptide chains, relative to ..gamma..-globin chains in heterozygous thalassemic mice, are present at approximately 80% of normal. The ratios of ..cap alpha..-globin to ..gamma..-globin RNA sequences are also 75 to 80% normal, exactly reflecting the ..cap alpha..-globin to ..gamma..-globin chain ratios. In the case ofmore » mutant 352HB, at least one ..cap alpha..-globin gene is deleted. Thalassemic mouse erythroid cells appear to compensate partially for the loss of half of their ..cap alpha..-globin genes.« less

  18. THE MONITORING OF EFFLUENT FOR ALPHA EMITTERS. PART II. METHODS FOR THE DETERMINATION OF URANIUM, POLONIUM AND OTHER ALPHA EMITTERS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smales, A.A.; Airey, L.; Woodward, J.

    1950-06-01

    Consideration has been given to the problem of separating and estimating uranium, polonium, and other alpha emitters (in order to provide analytical methods for their routine determination in conformily with the draft agreement on the Harwell effluent). Uranium may be ether extracted from solutions of ammonium nitrate as salting out agent at pHl with an efficiency of 98 to 99%. The deposition of polonium on silver foil is a specific method for this element and under prescribed conditions similar extraction efficiencies may be obtained. An adequate separation from all other alpha emitters'' is obtained and methods for the estimation ofmore » these are discussed. A comprehensive scheme involving a preliminary activity concentration step has been elaborated. Uranium, polonium, and the majority of the other alpha emitters'' are precipitated as their tannin complexes at pH8 using calcium hydroxide, the calcium-tannin complex acting as a carrier. That part of the activity remaining in solution is determined as in the total activity method, previously described. From the solution of the precipitate, polonium is first separated by electrodeposition, and then uranium by ether extraction in the presence of ammonium nitrate. The majority of the other alpha emitters'' still in the aqueous ammonium nitrate solution are collected on a second calcium-tannin precipitate, while the small part remaining in solution after this operation is obtained by direct evaporation. (auth)« less

  19. Emittance Theory for Cylindrical Fiber Selective Emitter

    NASA Technical Reports Server (NTRS)

    Chubb, Donald L.

    1998-01-01

    A fibrous rare earth selective emitter is approximated as an infinitely long, cylinder. The spectral emittance, e(sub x), is obtained L- by solving the radiative transfer equations with appropriate boundary conditions and uniform temperature. For optical depth, K(sub R), where alpha(sub lambda), is the extinction coefficient and R is the cylinder radius, greater than 1 the spectral emittance depths, K(sub R) alpha(sub lambda)R, is nearly at its maximum value. There is an optimum cylinder radius, R(sub opt) for maximum emitter efficiency, n(sub E). Values for R(sub opt) are strongly dependent on the number of emission bands of the material. The optimum radius decreases slowly with increasing emitter temperature, while the maximum efficiency and useful radiated power increase rapidly with increasing, temperature.

  20. Possible Mg ii emission in B stars observed from Copernicus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kondo, Y.; Modisette, J.L.; Dufour, R.J.

    1976-05-15

    Four B stars, ..cap alpha.. Vir, ..beta.. Cen, ..cap alpha.. Gru, and ..beta.. Lib, were observed with the Copernicus Princeton Telescope Spectrometer at a resolution of 0.1 A in order to investigate the presence of chromospheric emission. Emission was observed in ..beta.. Cen and ..cap alpha.. Gru, while the results for ..cap alpha.. Vir and ..beta.. Lib were inconclusive. (AIP)

  1. Synthesis of specifically deuterated S-benzylcysteines and of oxytocin and related diastereomers deuterated in the half-cystine positions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Upson, D.A.; Hruby, V.J.

    1976-04-16

    S-Benzylcysteine derivatives specifically deuterated at the ..cap alpha.. carbon only, the ..beta.. carbon only, and at both the ..cap alpha.. and ..beta.. carbons have been synthesized. These labeled compounds have been enzymatically resolved and the enantiomers and reacemates have been converted to the N-tert-butyloxycarbonyl derivatives. The deuterium labels were not exchanged under the conditions of the syntheses. Condensation of the sodium salt of diethyl ..cap alpha..-acetami-domalonate with benzyl chloromethyl sulfide followed by hydrolysis with DCl afforded S-benzyl-DL-(..cap alpha..-/sup 2/H/sub 1/) cysteine. Acetylation followed by treatment with hog renal acylase separated the stereoisomers. A Mannich reaction with (/sup 2/H/sub 2/) methylenemore » diacetate, diethyl ..cap alpha..-acetamido-..cap alpha..-dimethylamino(/sup 2/H/sub 2/)methylmalonate methiodide (15). Treatment of 15 with sodium benzylmercaptide gave diethyl ..cap alpha..-acetamido-..cap alpha..-benzylthio(/sup 2/H/sub 2/)methylmalonate, which was hydrolyzed with HCl to yield S-benzyl-DL-(..beta..,..beta..-/sup 2/H/sub 2/)cysteine or with DCl to afford S-benzyl-DL-(..cap alpha..,..beta..,..beta..,-/sup 2/H/sub 3/)cysteine. These compounds were resolved as before. The preparation of S-benzyl-DL-(..cap alpha..,..beta..,..beta..-/sup 2/H/sub 3/)cysteine required an efficient source of ethanol-d. This deuterated solvent was prepared in quantitative yield in 2 h from tetraethoxysilane, D/sub 2/O, and a catalytic amount of thionyl chloride. The protected deuterated amino acids were used in the preparation of several oxytocin analogues in which the specific deuteration appears in either the 1-hemicystine or the 6-hemicystine residues.« less

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chan, R.K.; Otte, C.A.

    Eight independently isolated mutants which are supersensitive (Sst/sup -/) to the G1 arrest induced by the tridecapeptide pheromone ..cap alpha.. factor were identified by screening mutagenized Saccharomyces cerevisiae MATa cells on solid medium for increased growth inhibition by ..cap alpha.. factor. These mutants carries lesions in two complementation groups, sst1 and sst2. Mutations at the sst1 locus were mating type specific: MATa sst1 cells were supersensitive to ..cap alpha.. factor, but MAT..cap alpha.. sst1 cells were not supersensitive to a factor. In contrast, mutations at the sst2 locus conferred supersensitivity to the pheromones of the opposite mating type on bothmore » MATa and MAT..cap alpha.. cells. Even in the absence of added ..cap alpha.. pheromone, about 10% of the cells in exponentially growing cultures of MATa strains carrying any of three different alleles of sst2 (including the ochre mutation sst2-4) had the aberrant morphology (''shmoo'' shape) that normally develops only after MATa cells are exposed to ..cap alpha.. factor. This ''self-shmooing'' phenotype was genetically linked to the sst2 mutations, although the leakiest allele isolated (sst2-3) did not display this characteristic. Normal MATa/MAT..cap alpha.. diploids do not respond to pheromones; diploids homozygous for an sst2 mutation (MATa/MAT..cap alpha.. sst2-1/sst2-1) were still insensitive to ..cap alpha.. factor. The sst1 gene was mapped to within 6.9 centimorgans of his6 on chromosome IX. The sst2 gene was unlinked to sst1, was not centromere linked, and was shown to be neither linked nor centromere distal to MAT on the right arm of chromosome III.« less

  3. Specific high-affinity binding sites for a synthetic gliadin heptapeptide of human peripheral blood lymphocytes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Payan, D.G.; Horvath, K.; Graf, L.

    1987-03-23

    The synthetic peptide containing residues 43-49 of ..cap alpha..-gliadin, the major protein component of gluten, has previously been shown to inhibit the production of lymphokine activities by mononuclear leukocytes. The authors demonstrate using radiolabeled ..cap alpha..-gliadin(43-49) that human peripheral blood lymphocytes express approximately 20,000-25,000 surface receptors for this peptide, with a dissociation constant (K/sub D/) of 20 nM. In addition, binding is inhibited by naloxone and an enkephalin analog, thus confirming the functional correlate which demonstrates inhibition by these agents of ..cap alpha..-gliadin(43-49) functional effects. Furthermore, B-lymphocytes bind specifically a greater amount of (/sup 125/I)..cap alpha..-gliadin(43-49) than T-lymphocytes. The lymphocytemore » ..cap alpha..-gliadin(43-49) receptor may play an important role in mediating the immunological response to ..cap alpha..-gliadin. 16 references, 4 figures.« less

  4. Enzymatic preparation of. cap alpha. - and. beta. -deuterated or tritiated amino acids with l-methionine. gamma. -lyase

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Esaki, N.; Sawada, S.; Tanaka, H.

    L-Methionine ..gamma..-lyase catalyzes the exchange of ..cap alpha..- and ..beta..-hydrogens of L-methionine and S-methyl-L-cysteine with deuterium or tritium of solvents. The rate of ..cap alpha..-hydrogen exchange with deuterium was about 40 times faster than that of the elimination reactions. The deuterium and tritium were exchanged also with the ..cap alpha..- and ..beta..-hydrogens of the straight-chain amino acids which do not undergo the elimination: L-alanine, L-..cap alpha..-aminobutyrate, L-norvaline, and L-norleucine. No exchange occurs for the D-isomers, acidic L-amino acids, basic L-amino acids, and branched-chain L-amino acids, although ..cap alpha..-hydrogen of glycine, L-trypotophan, and L-phenylalanine is exchanged slowly. These enzymatic hydrogen-exchange reactionsmore » facilitate specific labeling of the L-amino acids with deuterium and tritium.« less

  5. Purification and characterization of the glycoprotein hormone. cap alpha. -subunit-like material secreted by HeLa cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cox, G.S.; Rimerman, R.A.

    1988-08-23

    The protein secreted by HeLa cells that cross-reacts with antiserum developed against the ..cap alpha..-subunit of human chorionic gonadotropin (hCG) has been purified approximately 30,000-fold from concentrated culture medium by organic solvent fractionation followed by ion exchange, gel filtration, and lectin affinity chromatography. The final preparation had a specific activity (by RIA) of 6.8 x 10/sup 5/ ng of ..cap alpha../mg of protein and appeared homogeneous by electrophoresis on reducing/denaturing polyacrylamide gels (SDS-PAGE). Amino acid analysis indicated that HeLa-..cap alpha.. had a composition very similar to that of the urinary hCG ..cap alpha..-subunit. However, comparison of hCG-..cap alpha.. and HeLa-..capmore » alpha.. demonstrated that the tumor-associated subunit was not identical with its normal counterpart. The purified tumor protein had an apparent molecular weight greater than that of the urinary ..cap alpha..-subunit when analyzed by SDS-PAGE, and this difference was even greater when a partially purified preparation was examined by an immunoblot technique (Western). Isoelectric focusing of the HeLa and hCG subunits demonstrated that the tumor protein had a lower pI. Immunoprecipitation and electrophoresis of ..cap alpha..-subunit from HeLa cultures labeled with (/sup 3/H)fucose indicated that the tumor subunit was fucosylated, whereas analysis of hCG-..cap alpha.. hydrosylates by HPLC confirmed previous reports that the placental subunit does not contain fucose. The results indicate that, regardless of whether or not a single ..cap alpha..-subunit gene is being expressed in both normal and neoplastic tissues, posttranslational modifications lead to a highly altered subunit in the tumor. The differences observed may be useful in diagnosing neoplastic vs hyperplastic conditions and may lend insight into the mechanism of ectopic hormone production by tumors.« less

  6. Emittance measurements of Space Shuttle orbiter reinforced carbon-carbon

    NASA Technical Reports Server (NTRS)

    Caram, Jose M.; Bouslog, Stanley A.; Cunnington, George R., Jr.

    1992-01-01

    The spectral and total normal emittance of the Reinforced Carbon-Carbon (RCC) used on Space Shuttle nose cap and wing leading edges has been measured at room temperature and at surface temperatures of 1200 to 2100 K. These measurements were made on virgin and two flown RCC samples. Room temperature directional emittance data were also obtained and were used to determine the total hemispherical emittance of RCC as a function of temperature. Results of the total normal emittance for the virgin samples showed good agreement with the current RCC emittance design curve; however, the data from the flown samples showed an increase in the emittance at high temperature possibly due to exposure from flight environments.

  7. Velocity space instabilities of alpha particles in tokamak reactors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sigmar, D.J.

    1979-01-01

    In this lecture on high frequency instability due to isotropic hollow alpha velocity distributions it was first shown that such distributions can actually arise under thermonuclear conditions in a tokamak reactor, particularly for the case of imperfect alpha particle confinement. The toroidal geometry (i.e., the poloidal variation of the alpha gyrofrequency) then leads to linear instability of the compressional Alfven wave ..omega.. = C/sub A/k/sub perpendicular/ with k/sub parallel/ congruent to O, k/sub perpendicular/ rho/sub ..cap alpha../ greater than or equal to 1, v/sub ..cap alpha../ > C/sub A/, at the low harmonics ..omega.. congruent to n ..omega../sub c..cap alpha../.more » Thus the free energy of the inverted alpha distribution is accessible and produces anomalously rapid diffusion of F/sub ..cap alpha../(v/sub perpendicular/). (MOW)« less

  8. SU-E-J-03: A Comprehensive Comparison Between Alpha and Beta Emitters for Cancer Radioimmunotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, C.Y.; Guatelli, S; Oborn, B

    2014-06-01

    Purpose: The purpose of this study is to perform a comprehensive comparison of the therapeutic efficacy and cytotoxicity of alpha and beta emitters for Radioimmunotherapy (RIT). For each stage of cancer development, specific models were built for the separate objectives of RIT to be addressed:a) kill isolated cancer cells in transit in the lymphatic and vascular circulation,b) regress avascular cell clusters,c) regress tumor vasculature and tumors. Methods: Because of the nature of short range, high LET alpha and long energy beta radiation and heterogeneous antigen expression among cancer cells, the microdosimetric approach is essential for the RIT assessment. Geant4 basedmore » microdosimetric models are developed for the three different stages of cancer progression: cancer cells, cell clusters and tumors. The energy deposition, specific energy resulted from different source distribution in the three models was calculated separately for 4 alpha emitting radioisotopes ({sup 211}At, {sup 213}Bi, {sup 223}Ra and {sup 225}Ac) and 6 beta emitters ({sup 32}P, {sup 33}P, {sup 67}Cu, {sup 90}Y, {sup 131}I and {sup 177}Lu). The cell survival, therapeutic efficacy and cytotoxicity are determined and compared between alpha and beta emitters. Results: We show that internal targeted alpha radiation has advantages over beta radiation for killing isolated cancer cells, regressing small cell clusters and also solid tumors. Alpha particles have much higher dose specificity and potency than beta particles. They can deposit 3 logs more dose than beta emitters to single cells and solid tumor. Tumor control probability relies on deep penetration of radioisotopes to cancer cell clusters and solid tumors. Conclusion: The results of this study provide a quantitative understanding of the efficacy and cytotoxicity of RIT for each stage of cancer development.« less

  9. Alpha voltaic batteries and methods thereof

    NASA Technical Reports Server (NTRS)

    Jenkins, Phillip (Inventor); Scheiman, David (Inventor); Castro, Stephanie (Inventor); Raffaelle, Ryne P. (Inventor); Wilt, David (Inventor); Chubb, Donald (Inventor)

    2011-01-01

    An alpha voltaic battery includes at least one layer of a semiconductor material comprising at least one p/n junction, at least one absorption and conversion layer on the at least one layer of semiconductor layer, and at least one alpha particle emitter. The absorption and conversion layer prevents at least a portion of alpha particles from the alpha particle emitter from damaging the p/n junction in the layer of semiconductor material. The absorption and conversion layer also converts at least a portion of energy from the alpha particles into electron-hole pairs for collection by the one p/n junction in the layer of semiconductor material.

  10. Dusty Lyman-alpha Emitters As Seen By Spitzer

    NASA Astrophysics Data System (ADS)

    Dolan, Kyle; Scarlata, C.; Colbert, J. W.; Teplitz, H. I.; Hayes, M.

    2013-01-01

    We have used the IRAC and MIPS Spitzer archive to derive the full mid-IR SED for the largest sample of local Lyman-alpha emitters, probing the internal activities of these sources as well as analyzing the role that dust properties play in the Lyman-alpha escape fraction. We utilized all available IRAC and MIPS data for a sample of about 100 local Lyman-alpha emitters at redshift 0.2≤z≤0.4 , originally discovered by Deharveng et al. (2008) and Cowie et al. (2011), to quantify the level of star formation (SF) and AGN activity in these sources, probing into dust-enshrouded regions that block UV and optical photons from escaping. In order to derive the total bolometric IR luminosity from 8μm to 1000μm, we fit the IR data to the template SEDs derived by Chary and Elbaz (2001). Using this information, we quantified the total star formation rate (SFR) of these galaxies and how much SF is missed by optical and UV surveys. We also identified any AGN activity and produced new estimates for AGN contamination within the population of Lyman-alpha emitters. This work has been supported by NASA's Astrophysics Data Analysis Program, Award # NNX11AH84G.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Popp, R.A.; Marsh, C.L.; Skow, L.C.

    Hemoglobins of mouse embryos at 11.5 through 16.5 days of gestation were separated by electrophoresis on cellulose acetate and quantitated by a scanning densitometer to study the effects of two radiation-induced mutations on the expression of embryonic hemoglobin genes in mice. Normal mice produce three kinds of embryonic hemoglobins. In heterozygous ..cap alpha..-thalassemic embryos, expression of EI (x/sub 2/y/sub 2/) and EII (..cap alpha../sub 2/y/sub 2/) is deficient because the x- and ..cap alpha..-globin genes of one of the allelic pairs of Hba on chromosome 11 was deleted or otherwise inactivated by X irradiation. Simultaneous inactivation of the x- andmore » ..cap alpha..-globin genes indicates that these genes must be closely linked. Reduced x- and ..cap alpha..-chain synthesis results in an excess of y chains that associate as homotetramers. This unique y/sub 4/ hemoglobin also appears in ..beta..-duplication embryos where excess y chains are produced by the presence of three rather than two functional alleles of y- and ..beta..-globin genes. In double heterozygotes, which have a single functional allele of x- and ..cap alpha..-globin genes and three functional alleles of y- and ..beta..-globin genes, synthesis of ..cap alpha.. and non-..cap alpha.. chains is severely imbalanced and half of the total hemoglobin is y/sub 4/. Mouse y/sub 4/ has a high affinity for oxygen, P/sub 50/ of less than 10 mm Hg, but it lacks cooperativity so is inefficient for oxygen transport. The death of double heterozygotes in late fetal or neonatal life may be in large part to oxygen deprivation to the tissues.« less

  12. Galex Lyman-alpha Emitters: Physical Properties, Luminosity Bimodality, And Morphologies.

    NASA Astrophysics Data System (ADS)

    Mallery, Ryan P.

    2010-01-01

    The Galaxy Evolution Explorer spectroscopic survey has uncovered a large statistically significant sample of Lyman-alpha emitters at z sim0.3. ACS imaging of these sources in the COSMOS and AEGIS deep fields reveals that these Lyman-alpha emitters consist of two distinct galaxy morphologies, face on spiral galaxies and compact starburst/merging systems. The morphology bimodality also results in a bimodal distribution of optical luminosity. A comparison between the UV photometry and MIPS 24 micron detections of these sources indicates that they are bluer, and have less dust extinction than similar star forming galaxies that lack Lyman-alpha detection. Our findings show how the global gas and dust distribution of star forming galaxies inhibits Lyman-alpha emission in star forming galaxies. GALEX is a NASA Small Explorer, launched in April 2003. We gratefully acknowledge NASA's support for construction, operation, and science analysis for the GALEX mission, developed in cooperation with the CNES of France and the Korean Ministry of Science and Technology.

  13. Two subunits of the 55 K porcine zona pellucida glycoprotein family are immunologically distinct

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Subramanian, M.G.; Yurewicz, E.C.; Sacco, A.G.

    1986-03-01

    The 55K glycoprotein family (ZP3) of the porcine zona pellucida is comprised of two subunits of 46 K and 45 K which can be resolved by endo-..beta..-galactosidase digestion of ZP3 followed by reversed phase HPLC on Vydac C4 resin. Gel electrophoresis revealed that the 46 K component (EBDG..cap alpha..) is approx. 95% pure and the 45 K component (EBGD..beta..) is 100% pure. In the present study, these two subunits were evaluated immunologically by RIA. Under similar reaction protocols (chloramine-T iodination procedure) comparable specific activities were obtained for EBGD..cap alpha.. (33.06 +/- 7.5 ..mu..ci/..mu..gm), EBGD..beta.. (30.45 +/- 1.6) and ZP3 (26.3more » +/- 1.3). Antibody (Ab) titration studies revealed that EBGD..cap alpha.. and ..beta.. are potent immunogens and /sup 125/I-EBGD..cap alpha.. showed minimal cross reactivity to EBGD..beta..-Ab (8% bound at 1:500 dilution), whereas, /sup 125/I-EBGD..beta.. showed a greater degree of cross reactivity to EBGD..cap alpha..-Ab (23% bound at 1:500 dilution). Maximum binding for the two labeled antigens against homologous Abs (1:500) was > 60%. Dose response studies revealed that in the /sup 125/I-EBGD..cap alpha.. vs EBGD..cap alpha.. -Ab system, the 50% intercept was 3.25 +/- 0.32 ng for EBGD..cap alpha.. and 472.43 +/- 30.26 ng for EBGD..beta.. (p < 0.01), whereas, in the /sup 125/I-EBGD..beta.. vs EBGD..beta..-Ab system the 50% intercept was 3.51 +/- 0.58 for EBGD..beta.. and 166.77 +/- 49.20 for EBGD..cap alpha.. (p < 0.01). No significant differences were observed in the slopes of the dose response curves. It is concluded that the two subunits of ZP3 possess distinct immunologic characteristics as evaluated by RIA.« less

  14. Evidence for concerted kinetic oxidation of progesterone by purified rat hepatic cytochrome P-450g

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Swinney, D.C.; Ryan, D.E.; Thomas, P.E.

    1988-07-26

    Purified cytochrome P-450g, a male-specific rat hepatic isozyme, was observed to metabolize progesterone to two primary metabolites (6..beta..-hydroxyprogesterone and 16..cap alpha..-hydroxyprogesterone), two secondary metabolites (6..beta..,16..cap alpha..-dihydroxyprogesterone and 6-ketoprogesterone), and one tertiary metabolite (6-keto-16..cap alpha..-hydroxyprogesterone). The K/sub m,app/ for the formation of these products from progesterone was determined to be approximately 0.5 ..mu..M, while the K/sub m,app/ for metabolism of 6..beta..- and 16..cap alpha..-hydroxyprogesterone was found to be 5-10 ..mu..M. The ratio of primary to secondary metabolites did not change significantly at progesterone concentrations from 6 to 150 ..mu..M, and a lag in formation of secondary metabolites was not observed inmore » 1-min incubations. Concerted oxidation of progesterone to secondary products without the intermediate products leaving the active site was suggested by these results and confirmed by isotopic dilution experiments in which little or no dilution of metabolically formed 6..beta..,16..cap alpha..-dihydroxyprogesterone and 6-keto-16..cap alpha..-hydroxyprogesterone was observed in incubations containing a mixture of radiolabeled progesterone and unlabeled 6..beta..-hydroxyprogesterone or 16..cap alpha..-hydroxyprogesterone. Incubation of 6..beta..-hydroxyprogesterone with a reconstituted system in an atmosphere of /sup 18/I/sub 2/ resulted in > 90% incorporation of /sup 18/O in the 16..cap alpha..-position of 6..beta..,16..cap alpha..-dihydroxyprogesterone but no incorporation of /sup 18/O into 6-ketoprogesterone, even though the reaction was dependent upon enzyme and O/sub 2/, and not inhibited by mannitol, catalase, or superoxide dismutase. Factors which characterize the metabolism of progesterone by cytochrome P-450g in terms of active-site constraints and the catalytic competence of the enzyme in microsomes were also explored.« less

  15. Emilio G. Segrè - Patents

    Science.gov Websites

    neutrons to thermal energies. US 2,573,069 METHOD AND APPARATUS FOR MEASURING STRONG ALPHA EMITTERS - Segrà ¨, E. G.; October 30, 1951 (to the U.S. Atomic Energy Commission) This patent describes an apparatus and method for the determination of the strength of a strong alpha emitter. The apparatus is so

  16. Radioactive sample effects on EDXRF spectra

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Worley, Christopher G

    2008-01-01

    Energy dispersive X-ray fluorescence (EDXRF) is a rapid, straightforward method to determine sample elemental composition. A spectrum can be collected in a few minutes or less, and elemental content can be determined easily if there is adequate energy resolution. Radioactive alpha emitters, however, emit X-rays during the alpha decay process that complicate spectral interpretation. This is particularly noticeable when using a portable instrument where the detector is located in close proximity to the instrument analysis window held against the sample. A portable EDXRF instrument was used to collect spectra from specimens containing plutonium-239 (a moderate alpha emitter) and americium-241 (amore » heavy alpha emitter). These specimens were then analyzed with a wavelength dispersive XRF (WDXRF) instrument to demonstrate the differences to which sample radiation-induced X-ray emission affects the detectors on these two types of XRF instruments.« less

  17. Measurement system for alpha emitters in solution

    NASA Astrophysics Data System (ADS)

    Robert, A.; Sella, C.; Heindl, R.

    1984-08-01

    The measurement of alpha emitter concentrations in solution corresponds to a need felt in particular by laboratories working on actinides and in the spent fuel reprocessing industry. The instrument present here allows this measurement continuously by the use of a new scintillator that is insensitive to corrosive liquids. The extreme thinness of the scintillator guarantees good detection selectivity of alpha particles in the presence of beta and gamma emissions. Examples of uranium-233, plutonium-239 and americium-241 concentration measurements are presented.

  18. Studying Lyman-alpha escape and reionization in Green Pea galaxies

    NASA Astrophysics Data System (ADS)

    Yang, Huan; Malhotra, Sangeeta; Rhoads, James E.; Gronke, Max; Leitherer, Claus; Wofford, Aida; Dijkstra, Mark

    2017-01-01

    Green Pea galaxies are low-redshift galaxies with extreme [OIII]5007 emission line. We built the first statistical sample of Green Peas observed by HST/COS and used them as analogs of high-z Lyman-alpha emitters to study Ly-alpha escape and Ly-alpha sizes. Using the HST/COS 2D spectra, we found that Ly-alpha sizes of Green Peas are larger than the UV continuum sizes. We found many correlations between Ly-alpha escape fraction and galactic properties -- dust extinction, Ly-alpha kinematic features, [OIII]/[OII] ratio, and gas outflow velocities. We fit an empirical relation to predict Ly-alpha escape fraction from dust extinction and Ly-alpha red-peak velocity. In the JWST era, we can use this relation to derive the IGM HI column density along the line of sight of each high-z Ly-alpha emitter and probe the reionization process.

  19. Risk of Lung Cancer Mortality in Nuclear Workers from Internal Exposure to Alpha Particle-emitting Radionuclides

    PubMed Central

    Atkinson, Will; Bérard, Philippe; Bingham, Derek; Birchall, Alan; Blanchardon, Eric; Bull, Richard; Guseva Canu, Irina; Challeton-de Vathaire, Cécile; Cockerill, Rupert; Do, Minh T.; Engels, Hilde; Figuerola, Jordi; Foster, Adrian; Holmstock, Luc; Hurtgen, Christian; Laurier, Dominique; Puncher, Matthew; Riddell, Anthony E.; Samson, Eric; Thierry-Chef, Isabelle; Tirmarche, Margot; Vrijheid, Martine; Cardis, Elisabeth

    2017-01-01

    Background: Carcinogenic risks of internal exposures to alpha-emitters (except radon) are poorly understood. Since exposure to alpha particles—particularly through inhalation—occurs in a range of settings, understanding consequent risks is a public health priority. We aimed to quantify dose–response relationships between lung dose from alpha-emitters and lung cancer in nuclear workers. Methods: We conducted a case–control study, nested within Belgian, French, and UK cohorts of uranium and plutonium workers. Cases were workers who died from lung cancer; one to three controls were matched to each. Lung doses from alpha-emitters were assessed using bioassay data. We estimated excess odds ratio (OR) of lung cancer per gray (Gy) of lung dose. Results: The study comprised 553 cases and 1,333 controls. Median positive total alpha lung dose was 2.42 mGy (mean: 8.13 mGy; maximum: 316 mGy); for plutonium the median was 1.27 mGy and for uranium 2.17 mGy. Excess OR/Gy (90% confidence interval)—adjusted for external radiation, socioeconomic status, and smoking—was 11 (2.6, 24) for total alpha dose, 50 (17, 106) for plutonium, and 5.3 (−1.9, 18) for uranium. Conclusions: We found strong evidence for associations between low doses from alpha-emitters and lung cancer risk. The excess OR/Gy was greater for plutonium than uranium, though confidence intervals overlap. Risk estimates were similar to those estimated previously in plutonium workers, and in uranium miners exposed to radon and its progeny. Expressed as risk/equivalent dose in sieverts (Sv), our estimates are somewhat larger than but consistent with those for atomic bomb survivors. See video abstract at, http://links.lww.com/EDE/B232. PMID:28520643

  20. cap alpha. -D-Mannopyranosylmethyl-P-nitrophenyltriazene effects on the degradation and biosynthesis of N-linked oligosaccharide chains on. cap alpha. /sub 1/-acid glycoprotein by liver cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Docherty, P.A.; Aronson, N.N. Jr.

    1986-05-01

    The effects of ..cap alpha..-D-mannopyranosylmethyl-p-nitrophenyltriazene (..cap alpha..-ManMNT) on the degradation and processing of oligosaccharide chains on ..cap alpha../sub 1/-acid glycoprotein (AGP) were studied. Addition of the triazene to a perfused liver blocked the complete degradation of endocytosed N-acetyl (/sup 14/C)glucosamine-labeled asialo-AGP and caused the accumulation of Man/sub 2/GlcNAc/sub 1/ fragments in the lysosome-enriched fraction of the liver homogenate. This compound also reduced the reincorporation of lysosomally-derived (/sup 14/C)GlcNAc into newly secreted glycoproteins. Cultured hepatocytes treated with the inhibitor synthesized and secreted fully-glycosylated AGP. However, the N-linked oligosaccharide chains on AGP secreted by the ..cap alpha..-ManMNT-treated hepatocytes remained sensitive to digestionmore » with endoglycosidase H, were resistant to neuraminidase, and consisted of Man/sub 9-7/GlcNAc/sub 2/ structures as analyzed by high resolution Bio-Gel P-4 chromatography. As measured by their resistance to cleavage by endoglycosidase H, the normal processing of all six carbohydrate chains on AGP to the complex form did not completely resume until nearly 24 h after triazene treatment. Since ManMNT is likely to irreversibly inactivate ..cap alpha..-D-mannosidases, the return of AGP to secretory forms with complex chains after 24 h probably resulted from synthesis of new processing enzymes.« less

  1. The X-ray Crystal Structures of Human {alpha}-Phosphomannomutase 1 Reveal the Structural Basis of Congenital Disorder of Glycosylation Type 1a

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Silvaggi,N.; Zhang, C.; Lu, Z.

    2006-01-01

    Carbohydrate-deficient glycoprotein syndrome type 1a (CDG-1a) is a congenital disease characterized by severe defects in nervous system development. It is caused by mutations in alpha -phosphomannomutase (of which there are two isozymes, {alpha}-PMM1 and {alpha}-PPM2). Here we report the X-ray crystal structures of human {alpha}-PMM1 in the open conformation, with and without the bound substrate, {alpha}-D-mannose 1-phosphate. {alpha}-PMM1, like most Haloalkanoic Acid Dehalogenase Superfamily (HADSF) members, consists of two domains, the cap and core, which open to bind substrate and then close to provide a solvent exclusive environment for catalysis. The substrate phosphate group is observed at a positively chargedmore » site of the cap domain, rather than at the core domain phosphoryl-transfer site defined by the D19 nucleophile and Mg{sup 2+} cofactor. This suggests that substrate binds first to the cap and then is swept into the active site upon cap closure. The orientation of the acid/base residue D21 suggests that {alpha}-PMM uses a different method of protecting the aspartylphosphate from hydrolysis than the HADSF member {beta}-phosphoglucomutase. It is hypothesized that the electrostatic repulsion of positive charges at the interface of the cap and core domains stabilizes {alpha}-PMM1 in the open conformation, and that the negatively charged substrate binds to the cap, thereby facilitating its closure over the core domain. The two isozymes {alpha}-PMM1 and {alpha}-PMM2 are shown to have a conserved active-site structure and to display similar kinetic properties. Analysis of the known mutation sites in the context of the structures reveals the genotype-phenotype relationship underlying CDG-1a.« less

  2. Genomic organization and sequence of the Gus-s/sup a/ allele of the murine. beta. -glucuronidase gene

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Funkenstein, B.; Leary, S.L.; Stein, J.C.

    1988-03-01

    The Gus-s/sup ..cap alpha../ allele of the mouse ..beta..-glucuronidase gene exhibits a high degree of inducibility by androgens due to its linkage with the Gus-r/sup ..cap alpha../ regulatory locus. The authors isolated Gus-s/sup ..cap alpha../ on a 28-kilobase pair fragment of mouse chromosome 5 and found that it contains 12 exons and 11 intervening sequences spanning 14 kilobase pairs of this genomic segment. The mRNA cap site was identified by ribonuclease protection and primer extension analyses which revealed an unusually short 5' noncoding sequence of 12 nucleotides. Proximal regulatory sequences in the 5'-flanking DNA and the complete sequence of themore » Gus-s/sup ..cap alpha../ mRNA transcript were also determined. Comparison of the amino acid sequence determined from the Gus-s/sup ..cap alpha../ nucleotide sequence with that of human ..beta..-glucuronidase indicated that the two human mRNA species differ due to alternate splicing of an exon homologous to exon 6 of the mouse gene.« less

  3. Creatine kinase and alpha-actin mRNA levels decrease in diabetic rat hearts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Popovich, B.; Barrieux, A.; Dillmann, W.H.

    1987-05-01

    Diabetic cardiomyopathy is associated with cardiac atrophy and isoenzyme redistribution. To determine if tissue specific changes occur in mRNAs coding for ..cap alpha..-actin and creatine kinase (CK), they performed RNA blot analysis. Total ventricular RNA from control (C) and 4 wk old diabetic (D) rats were hybridized with /sup 32/P cDNA probes for ..cap alpha..-actin and CK. A tissue independent cDNA probe, CHOA was also used. Signal intensity was quantified by photodensitometry. D CK mRNA was 47 +/- 16% lower in D vs C. Insulin increases CK mRNA by 20% at 1.5 hs, and completely reverses the deficit after 4more » wks. D ..cap alpha..-actin mRNA is 66 +/- 18% lower in D vs C. Insulin normalized ..cap alpha..-actin mRNA by 5 hs. CHOA mRNA is unchanged in D vs C, but D + insulin CHOA mRNA is 30 +/- 2% lower than C. In rats with diabetic cardiomyopathy, muscle specific CK and ..cap alpha..-actin mRNAs are decreased. Insulin treatment reverses these changes.« less

  4. Gamma-resonance investigation of the kinetics of the reduction of (. cap alpha. -benzil dioximato-1)(. cap alpha. -benzil dioximato-2)di(pyridine)iron(III)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Turte, K.I.; Bulgak, I.I.; Stukan, R.A.

    1986-07-01

    (..cap alpha..-Benzil dioximato-1)(..cap alpha..-benzil dioximato-2)di(pyridine)iron(III) in the form of the diacetone solvate (II) is spontaneously converted at room temperature into (..cap alpha..-benzil dioximato-1)(..cap alpha..-benzil dioximato-2)di(pyridine)iron(II) (III). The quantitative composition of a sample containing complexes II and III has been determined as a function of the temperature and the time by gamma-resonance spectroscopy, which made it possible to investigate the kinetics of this reaction. The changes obtained in the percentage of complex II in the sample as a function of time at a given temperature was treated with the use of the Kolmogorov-Erofeev equation for a topochemical reaction of the typemore » A/sub s/ ..-->.. B/sub s/ + C/sub g/. The rate constants of the reaction at various temperatures and the activation energy *E have been determined. In the temperature range from 293 to 304/sup 0/K *E = 25.6 kcal/mole. The possibilities of gamma-resonance spectroscopy in the investigation of topochemical reactions associated with changes in the oxidation state of iron ions have been demonstrated.« less

  5. Reconstitution of high affinity. cap alpha. /sub 2/ adrenergic agonist binding by fusion with a pertussis toxin substrate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, M.H.; Neubig, R.R.

    1986-03-05

    High affinity ..cap alpha../sub 2/ adrenergic agonist binding is thought to occur via a coupling of the ..cap alpha../sub 2/ receptor with N/sub i/, the inhibitory guanyl nucleotide binding protein. Human platelet membranes pretreated at pH 11.5 exhibit a selective inactivation of agonist binding and N/sub i/. To further study the mechanism of agonist binding, alkali treated membranes (ATM) were mixed with membranes pretreated with 10 ..mu..M phenoxybenzamine to block ..cap alpha../sub 2/ receptors (POB-M). The combined membrane pellet was incubated in 50% polyethylene glycol (PEG) to promote membrane-membrane fusion and assayed for binding to the ..cap alpha../sub 2/ agonistmore » (/sup 3/H)UK 14,304 (UK) and the antagonist (/sup 3/H) yohimbine. PEG treatment resulted in a 2-4 fold enhancement of UK binding whereas yohimbine binding was unchanged. No enhancement of UK binding was observed in the absence of PEG treatment. The reconstitution was dependent on the addition of POB-M. They found that a 1:1 ratio of POB-M:ATM was optimal. Reconstituted binding was inhibited by GppNHp. Fusion of rat C6 glioma cell membranes, which do not contain ..cap alpha../sub 2/ receptors, also enhanced agonist binding to ATM. Fusion of C6 membranes from cells treated with pertussis toxin did not enhance (/sup 3/H) UK binding. These data show that a pertussis toxin sensitive membrane component, possibly N/sub i/, can reconstitute high affinity ..cap alpha../sub 2/ agonist binding.« less

  6. Ionization of isocitrate bound to pig hear NADP/sup +/-dependent isocitrate dehydrogenase: /sup 13/C NMR study of substrate binding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ehrlich, R.S.; Colman, R.F.

    1987-06-16

    Isocitrate and ..cap alpha..-ketoglutarate have been synthesized with carbon-13 enrichment at specific positions. The /sup 13/C NMR spectra of these derivatives were measured as a function of pH. The magnitudes of the changes in chemical shifts with pH for free isocitrate and the magnesium-isocitrate complex suggest that the primary site of ionization at the ..beta..-carboxyl. In the presence of the enzyme NADP/sup +/-dependent isocitrate dehydrogenase and the activating metal magnesium, the carbon-13 resonances of all three carboxyls remain constant from pH 5.5 to pH 7.5. Thus, the carboxyls remain in the ionized form in the enzyme-isocitrate complex. The ..cap alpha..-hydroxylmore » carbon resonance could not be located in the enzyme-isocitrate complex, suggesting immobilization of this group. Magnesium produces a 2 ppm downfield shift of the ..beta..-carboxyl but does not change the resonances of the ..cap alpha..- and ..gamma..-carboxyls. This result is consistent with metal activation of both the dehydrogenation and decarboxylation reactions. The /sup 13/C NMR spectrum of ..cap alpha..-ketoglutarate remains unchanged in the presence of isocitrate dehydrogenase, implying the absence of alterations in geometry in the enzyme-bound form. Formation of the quaternary complex with Mg/sup 2 +/ and NADPH leads to loss of the ..cap alpha..-ketoglutarate resonances and the appearance of new resonances characteristic of ..cap alpha..-hydroxyglutarate. In addition, a broad peak ascribed to the enol form of ..cap alpha..-ketoglutarate is observed. The substantial change in the shift of the ..beta..-carboxyl of isocitrate and the lack of significant shifts in the other carboxyls of isocitrate or ..cap alpha..-ketoglutarate suggest that interaction of the ..beta..-carboxyl with the enzyme contributes to the tighter binding of isocitrate and may be significant for the oxidative decarboxylation function of isocitrate dehydrogenase.« less

  7. Lyman-alpha observations of comet Kohoutek 1973 XII with Copernicus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Drake, J.F.; Jenkins, E.B.; Bertaux, J.L.

    1976-10-01

    Comet Kohoutek 1973 XII was observed with the Princeton telescope-spectrometer on the Copernicus satellite on six occasions over a 1-month period starting on 1974 January 29. Positive detection of the cometary L..cap alpha.. emission profile was obtained on January 29 and February 2. Earlier observations of the geocoronal L..cap alpha.. emission profile allowed an instrumental intensity calibration and confirmation of the computed instrumental profile for an extended source at the L..cap alpha.. wavelength.After allowing for broadening by the instrument, we derived from the width of the L..cap alpha.. emission on January 29 a hydrogen-outflow velocity of 10.6 +- 1.8 kmmore » s/sup -1/. The intensity calibration combined with an appropriate cometary model led to cometary water-production rates with average values of 1.3 +- 0.4 x 10/sup 28/ molecules sr/sup -1/ s/sup -1/ for January 29 and 6.0 +- 2.5 x 10/sup 27/ molecules sr/sup -1/ s/sup -1/ for February 2. Only upper limits were obtained for L..cap alpha.. on and after February 14. Searches for OH and D led to negative results. (AIP)« less

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chan, R.K.; Otte, C.A.

    Saccharomyces cerevisiae MATa cells carrying mutations in either sst1 or sst2 are supersensitive to the G1 arrest induced by ..cap alpha.. factor pheromone. When sst1 mutants were mixed with normal SST/sup +/ cells, the entire population recovered together from ..cap alpha.. factor arrest, suggesting that SST/sup +/ cells helped sst1 mutants to recover. Complementation tests and linkage analysis showed that sst1 and bar1, a mutation which eliminates the ability of MATa cells to act as a ''barrier'' to the diffusion of ..cap alpha.. factor, were lesions in the same genes. These findings suggest that sst1 mutants are defective in recoverymore » from ..cap alpha.. factor arrest because they are unable to degrade the pheromone. In contrast, recovery of sst2 mutants was not potentiated by the presence of SST/sup +/ cells in mixing experiments. When either normal MATa cells or mutant cells carrying defects in sst1 or sst2 were exposed to ..cap alpha.. factor for 1 h and then washed free of the pheromone, the sst2 cells subsequently remained arrested in the absence of ..cap alpha.. factor for a much longer time than SST/sup +/ or sst1 cells. These observations suggest that the defect in sst2 mutants is intrinsic to the cell and is involved in the mechanism of ..cap alpha.. factor action at some step after the initial interaction of the pheromone with the cell. The presence of an sst2 mutation appears to cause a growth debility, since repeated serial subculture of haploid sst2-1 strains led to the accumulation of faster-growing revertants that were pheromone resistant and were mating defective (''sterile'').« less

  9. Isolation of human hexosaminidase. cap alpha. cDNA and expression of. cap alpha. chains in E. coli

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wiktorowicz, J.E.; Whitman, J.M.

    1986-05-01

    Pooled antisera against homogeneous, glutaraldehyde cross-linked hexosaminidase (hex) A was adsorbed with E. coli lysate insolubilized on Sepharose 4B. Aliquots of a human liver lambdagtll cDNA library (50,000-100,000 pfu) were plated on E. coli Y1090. Expression of cloned cDNA, after sufficient plaque growth at 42/sup 0/, was accomplished by induction with isopropylthiogalactoside soaked nitrocellulose filters. Identification of hex cDNA clones was performed by incubation of the filters with purified antisera. Protein A labelled with I-125 was used to develop the reactive plaques. Positive plaques, identified by autoradiography, were picked, replated at a lower density, and rescreened. This was repeated severalmore » more times until all plaques yielded positive signals. Identification of the clones as containing ..cap alpha.. or ..beta.. cDNA was accomplished by replating the purified phage and rescreening the plaques with anti-hex B antiserum preadsorbed with E. coli lysate. According to this protocol several hex ..cap alpha.. clones have been identified. While these clones generate ..beta..-galactosidase: hex ..cap alpha.. fusion proteins, these findings suggest that in the future it may be possible to obtain large quantities of unmodified hex ..cap alpha.. and ..beta.. polypeptides from E. coli for the study of the structural and enzymatic properties of these polypeptides and for diagnostic purposes in the GM2 gangliosidoses.« less

  10. Pulse radiolysis and 77 K matrix. gamma. irradiation of dimethyl truxinates and trans-methyl cinnamate in 2-methyltetrahydrofuran

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takamuku, S.; Kigawa, H.; Suematsu, H.

    1982-05-13

    One-electron reduction of dimethyl ..mu..-truxinate (..mu..-DMT), dimethyl ..beta..-truxinate (..beta..-DMT), and dimethyl ..cap alpha..-truxillate (..cap alpha..-DMT) has been investigated by pulse radiolysis and 77 K matrix ..gamma.. irradiation of the 2-methyltetrahydrofuran solutions. Cycloreversion of the radical anions formed by an electron attachment to these cyclobutanes was observed in all cases, even at 77 K. The orientation of the cycloreversion was dependent on the stereochemistry of the cyclobutanes, and the selectivity was reasonably explained by a so-called cis effect; the best possible release of steric hindrance decides the primary step of the reaction. In 77 K matrix ..gamma.. irradiation of ..cap alpha..-DMT,more » an intense IR absorption was found after the photobleaching of trapped electrons with light > 690 nm. In other DMTs, the IR absorption band was not observed while the cycloreversion of DMT by mobile electrons occurred. Thus, the IR band in the case of ..cap alpha..-DMT was assigned to an associated dimer anion due to the interaction between the radical anion and the neutral molecule pair of trans-methyl cinnamate orginally formed by the cycloreversion of ..cap alpha..-DMT. The dimer anion was presumed to be oriented in a head-to-tail structure in a solvent cage on the basis of the original configuration of ..cap alpha..-DMT.« less

  11. Pheromone induction of agglutination in Saccharomyces cerevisiae a cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Terrance, K.; Lipke, P.N.

    1987-10-01

    a-Agglutinin, the cell surface sexual agglutinin of yeast a cells, was assayed by its ability to bind its complementary agglutinin, ..cap alpha..-agglutinin. The specific binding of /sup 125/I-..cap alpha..-agglutinin to a cells treated with the sex pheromone ..cap alpha..-factor was 2 to 2.5 times that of binding to a cells not treated with ..cap alpha..-factor. Competition with unlabeled ..cap alpha..-agglutinin revealed that the increased binding was due to increased cell surface expression of a-agglutinin, with no apparent change in the binding constant. The increase in site number was similar to the increase in cellular agglutinability. Increased expression of a-agglutinin followedmore » the same kinetics as the increase in cellular agglutinability, with a 10-min lag followed by a 15- to 20-min response time. Induction kinetics were similar in cells in phases G1 and G2 of the cell cycle. Maximal expression levels were similar in cells treated with excess pheromone and in cells exposed to pheromone after destruction of constitutively expressed a-agglutinin.« less

  12. Evaluations of carbon nanotube field emitters for electron microscopy

    NASA Astrophysics Data System (ADS)

    Nakahara, Hitoshi; Kusano, Yoshikazu; Kono, Takumi; Saito, Yahachi

    2009-11-01

    Brightness of carbon nanotube (CNT) emitters was already reported elsewhere. However, brightness of electron emitter is affected by a virtual source size of the emitter, which strongly depends on electron optical configuration around the emitter. In this work, I- V characteristics and brightness of a CNT emitter are measured under a practical field emission electron gun (e-gun) configuration to investigate availability of CNT for electron microscopy. As a result, it is obtained that an emission area of MWNT is smaller than its tip surface area, and the emission area corresponds to a five-membered-ring with 2nd nearest six-membered-rings on the MWNT cap surface. Reduced brightness of MWNT is measured as at least 2.6×109 A/m 2 sr V. It is concluded that even a thick MWNT has enough brightness under a practical e-gun electrode configuration and suitable for electron microscopy.

  13. Lower thresholds for lifetime health effects in mammals from high-LET radiation - Comparison with chronic low-LET radiation.

    PubMed

    Sazykina, Tatiana G; Kryshev, Alexander I

    2016-12-01

    Lower threshold dose rates and confidence limits are quantified for lifetime radiation effects in mammalian animals from internally deposited alpha-emitting radionuclides. Extensive datasets on effects from internal alpha-emitters are compiled from the International Radiobiological Archives. In total, the compiled database includes 257 records, which are analyzed by means of non-parametric order statistics. The generic lower threshold for alpha-emitters in mammalian animals (combined datasets) is 6.6·10 -5  Gy day -1 . Thresholds for individual alpha-emitting elements differ considerably: plutonium and americium - 2.0·10 -5  Gy day -1 ; radium - 2.1·10 -4  Gy day -1 . Threshold for chronic low-LET radiation is previously estimated at 1·10 -3  Gy day -1 . For low exposures, the following values of alpha radiation weighting factor w R for internally deposited alpha-emitters in mammals are quantified: w R (α) = 15 as a generic value for the whole group of alpha-emitters; w R (Pu) = 50 for plutonium; w R (Am) = 50 for americium; w R (Ra) = 5 for radium. These values are proposed to serve as radiation weighting factors in calculations of equivalent doses to non-human biota. The lower threshold dose rate for long-lived mammals (dogs) is significantly lower than comparing with the threshold for short-lived mammals (mice): 2.7·10 -5  Gy day -1 , and 2.0·10 -4  Gy day -1 , respectively. The difference in thresholds is exactly reflecting the relationship between the natural longevity of these two species. Graded scale of severity in lifetime radiation effects in mammals is developed, based on compiled datasets. Being placed on the severity scale, the effects of internal alpha-emitters are situated in the zones of considerably lower dose rates than effects of the same severity caused by low-LET radiation. RBE values, calculated for effects of equal severity, are found to depend on the intensity of chronic exposure: different RBE values are characteristic for low, moderate, and high lifetime exposures (30, 70, and 13, respectively). The results of the study provide a basis for selecting correct values of radiation weighting factors in dose assessment to non-human biota. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Metabolism of 4-chlorobenzotrichloride in rats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Quistad, G.B.; Mulholland, K.M.; Skiles, G.

    Special analytical methodology was developed for purification of 4-chloro(/sup 14/C)benzotrichloride, which is both volatile and hydrolytically unstable at milligram mass levels. When rats were given a single oral dose of 4-chloro(/sup 14/C)benzotrichloride at 1.5 mg/kg, within 4-6 days 87 and 9% of the applied /sup 14/C were excreted in urine and feces, respectively. The major urinary metabolite was identified as 4-chlorohippuric acid, representing 78% of the applied dose. While about two-thirds of the fecal /sup 14/C residues were unextractable with organic solvents, free 4-chlorobenzoic acid and ..cap alpha..,..cap alpha..,4,4'-tetrachlorostilbene contributed 10 and 8% of the fecal /sup 14/C. The metabolicmore » production of ..cap alpha..,..cap alpha..,4,4'-tetrachlorostilbene appears to occur by a novel metabolic pathway.« less

  15. cap alpha. -Methylglucoside satisfies only Na/sup +/-dependent transport system of intestinal epithelium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kimmich, G.A.; Randles, J.

    1981-01-01

    The unidirectional influx of ..cap alpha..-methylglucoside (..cap alpha..-MG) by isolated chicken intestinal epithelial cells is 98% inhibited by phlorizin. The remaining 2% of the total influx occurs in the absence of Na/sup +/, is not sensitive to phloretin, and is equal to the diffusional entry rate for 2-deoxyglucose. The glucoside is much more strongly accumulated (75-fold) than 3-O-methylglucose (3-OMG) (10-fold). Inhibitors of the serosal sugar carrier (phloretin, cytochalasin B, theophylline, and flavanoids) do not enhance ..cap alpha..-MG accumulation. It is concluded that the glycoside is not a substrate for the intestinal serosal transport system. Steady-state gradients of the sugar canmore » be represented accurately by a concentrative, phlorizin-sensitive system that is opposed by a diffusional efflux process.« less

  16. Characterization of rat leydig cell gonadotropin receptor structure by affinity cross-linking

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Q.Y.; Hwang, J.; Menon, K.M.J.

    1986-05-01

    The gonadotropin receptor from rat leydig cell has been characterized with respect to binding kinetics and physiological regulation. The present study was intended to examine the structure of the receptor. Leydig cell suspension was prepared by either collagenase digestion or by mechanical disruption of the testis. The cells were incubated with /sup 125/I-hCG and the unreacted hCG was removed by centrifugation. The /sup 125/I-hCG was then covalently linked to the cell surface receptor using cleavable (dithiobis (succinimidyl propionate)) and non-cleavable (disuccinimidyl suberate) cross-linking reagents. The extracted cross-linked membrane proteins were resolved on SDS-polyacrylamide gels under reducing and non-reducing conditions andmore » subjected to autoradiographic analysis. Under non-reducing conditions, two labeled species with M/sub r/ = 87,000 and 120,000 were detected. However, only one labeled band was detected under reducing conditions with M/sub r/ = 64,000. The binding of /sup 125/I-hCG to the receptor was inhibited by hCG and LH, but not by a number of peptides and proteins. The data suggest that hCG receptor in leydig cell is an oligomeric complex consisting of four subunits, ..cap alpha cap alpha beta gamma... The ..beta.. and ..gamma.. subunits are each linked to an ..cap alpha.. subunit through disulfide linkage and the hormone binds to each ..cap alpha.. subunit. The two dimers formed (..cap alpha beta cap alpha gamma..) are associated by noncovalent interactions.« less

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamashita, T.; Fujino, T.; Masaki, N.

    The structural parameters of ..cap alpha..- and ..beta..-CdUO/sub 4/ crystals are determined by x-ray powder diffraction technique. ..cap alpha..-CdUO/sub 4/ is rhombohedral and cell parameters are a = 6.233(3) A and ..cap alpha.. = 36.12(5)/sup 0/. ..beta..-CdUO/sub 4/ crystallizes in a C-centered orthorhombic cell with a = 7.023(4), b = 6.849(3), c = 3.514(2) A. The space groups are R3m for ..cap alpha..-CdUO/sub 4/ and Cmmm for ..beta..-CdUO/sub 4/. ..cap alpha..-CdUO/sub 4/: 1U in (000), 1Cd in (1/2 1/2 1/2), 2O(1) in +-(uuu), 2O(2) in +-(vvv); u = 0.113, v= 0.350, Z = 1. ..beta..-CdUO/sub 4/: 2U in (000; 1/2more » 1/2 0), 2Cd in (1/2 0 1/2; 0 1/2 1/2), 40(1) in (0, +-y, 0; 1/2, 1/2 +-y, 0), 4O(2) in (+-x, 0, 1/2; 1/2 +-x, 1/2, 1/2); x = 0.159, y = 0.278, Z = 2. ..beta..-CdUO/sub 4/ contains collinear uranyl UO/sub 2//sup 2 +/ groups with a U-O(1) distance of 1.91 A, located either along or parallel to the c axis whereas the U-O(1) bond length in ..cap alpha..-CdUO/sub 4/ is 1.98 A which is longer than the usual uranyl bond length.« less

  18. Variability of Lyman-alpha emission from Jupiter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cochran, W.D.; Barker, E.S.

    1979-12-01

    The Jovian L..cap alpha.. emission line was reobserved in 1978 March using the high-resolution spectrometer of the Copernicus satellite. An intensity of 8.3 +- 2.9 kilorayleighs was measured. This value represents a significant increase in intensity over previous (1976) Copernicus observations, but is lower than the recent (1979) values obtained by Voyager 1 and IUE. The increase in intensity has been accompanied by a significant increase in line width givin strong support to the theory that the emission results from resonant scattering of the solar L..cap alpha.. line by H atoms in the upper Jovian atmosphere. The strength of Jovianmore » L..cap alpha.. emission correlates well with the level of solar activity. The solar extreme ultraviolet radiation varies with the solar cycle. This radiation causes the dissociation of H/sub 2/ and CH/sub 4/ into H atoms in the Jovian atmosphere. Therefore, in times of high solar activity, the H column density will increase, causing the observed stronger Jovian L..cap alpha.. emission.« less

  19. A remarkable member of the polyoxometalates: the eight-nickel-capped alpha-keggin polyoxoazonickelate.

    PubMed

    Dong, Lanjun; Huang, Rudan; Wei, Yongge; Chu, Wei

    2009-08-17

    The eight-nickel-capped polyoxoazonickelate, [Ni(20)(OH)(24)(MMT)(12)(SO(4))](NO(3))(2).6H(2)O (1; MMT = 2-mercapto-5-methyl-1,3,4-thiadiazole), has been synthesized, which has an alpha-Keggin structure with eight nickel caps. In this structure, the polyatom is the late transition metal Ni(II); the central heteroatom is S, and the organic terminal ligand becomes the primary part of the Keggin structure. This is a Keplerate-type cluster, which shows a central Ni(II)(12) cuboctahedron formed by the 12 Ni(II) centers of the classical alpha-Keggin core and a Ni(II)(8) hexahedron formed by the eight nickel caps.

  20. Glucocorticoids inhibit coordinated translation of. cap alpha. - and. beta. -globin mRNAs in Friend erythroleukemia cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Papaconstantinou, J.; Stewart, J.A.; Rabek, J.P.

    The dimethylsulfoxide (Me/sub 2/SO)-mediated induction of hemoglobin synthesis in Friend erythroleukemia cells is inhibited by the glucocorticoids hydrocortisone, dexamethasone, and fluocinolone acetonide; hydrocortisone, at concentrations of 10/sup -5/ to 10/sup -8/ M inhibits by 90-30% and fluocinolone acetonide at concentrations of 10/sup -8/ to 10/sup -11/ M shows a greater than 90% inhibition. At these concentrations the hormones have no effect on cell growth or viability. In this study it has been shown that there is a group of proteins, including the ..cap alpha..- and ..beta..-globins, whose regulation is associated with the induction of Friend erythroleukemia cell differentiation, and thatmore » the expression of these, in addition to ..cap alpha..- and ..beta..-globin, is affected by glucocorticoids. It is concluded that, although the translation of ..cap alpha..- and ..beta..-globin mRNA is a major site of inhibition by glucocorticoids, there is a detectable amount of ..cap alpha..- and ..beta..-globin mRNA translation which results in unequal amounts of globin synthesis and an overall more potent inhibition of hemoglobin formation.« less

  1. High-speed and on-chip graphene blackbody emitters for optical communications by remote heat transfer.

    PubMed

    Miyoshi, Yusuke; Fukazawa, Yusuke; Amasaka, Yuya; Reckmann, Robin; Yokoi, Tomoya; Ishida, Kazuki; Kawahara, Kenji; Ago, Hiroki; Maki, Hideyuki

    2018-03-29

    High-speed light emitters integrated on silicon chips can enable novel architectures for silicon-based optoelectronics, such as on-chip optical interconnects, and silicon photonics. However, conventional light sources based on compound semiconductors face major challenges for their integration with a silicon-based platform because of their difficulty of direct growth on a silicon substrate. Here we report ultra-high-speed (100-ps response time), highly integrated graphene-based on-silicon-chip blackbody emitters in the near-infrared region including telecommunication wavelength. Their emission responses are strongly affected by the graphene contact with the substrate depending on the number of graphene layers. The ultra-high-speed emission can be understood by remote quantum thermal transport via surface polar phonons of the substrates. We demonstrated real-time optical communications, integrated two-dimensional array emitters, capped emitters operable in air, and the direct coupling of optical fibers to the emitters. These emitters can open new routes to on-Si-chip, small footprint, and high-speed emitters for highly integrated optoelectronics and silicon photonics.

  2. X-ray fluorescence cross sections for K and L x rays of the elements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krause, M.O.; Nestor, C.W. Jr.; Sparks, C.J. Jr.

    1978-06-01

    X-ray fluorescence cross sections are calculated for the major x rays of the K series 5 less than or equal to Z less than or equal to 101, and the three L series 12 less than or equal to Z less than or equal to 101 in the energy range 1 to 200 keV. This calculation uses Scofield's theoretical partical photoionization cross sections, Krause's evaluation of fluorescence and Coster-Kronig yields, and Scofield's theoretical radiative rates. Values are presented in table and graph format, and an estimate of their accuracy is made. The following x rays are considered: K..cap alpha../sub 1/,more » K..cap alpha../sub 1/,/sub 2/, K..beta../sub 1/, K..beta../sub 1/,/sub 3/, L..cap alpha../sub 1/, L..cap alpha../sub 1/,/sub 2/, L..beta../sub 1/, L..beta../sub 2/,/sub 15/, L..beta../sub 3/, Ll, L..gamma../sub 1/, L..gamma../sub 4/, and L/sub 1/ ..-->.. L/sub 2/,/sub 3/. For use in x-ray fluorescence analysis, K..cap alpha.. and L..cap alpha.. fluorescence cross sections are presented at specific energies: TiK identical with 4.55 keV, CrK identical with 5.46 keV, CoK identical with 7.00 keV, CuK identical with 8.13 keV, MoK..cap alpha.. identical with 17.44 keV, AgK identical with 22.5 keV, DyK identical with 47.0 keV, and /sup 241/Am identical with 59.54 keV. Supplementary material includes fluorescence and Coster--Kronig yields, fractional radiative rates, fractional fluorescence yields, total L-shell fluorescence cross sections, fluorescence and Coster-Kronig yields in condensed matter, effective fluorescence yields, average L-shell fluorescence yield, L-subshell photoionization cross section ratios, and conversion factors from barns per atom to square centimeters per gram.« less

  3. Cross-linking of hCG to luteal receptors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ji, T.H.; Ji, I.

    1985-01-01

    Photoaffinity labeling of the lutropin/choriogonadotropin (LH/hCG) receptor system on porcine granulosa cells has demonstrated that both the ..cap alpha.. and ..beta.. subunits of hCG directly photoaffinity label the hormone receptor. Three new bands appear on SDS-PAGE as a consequence of photoaffinity labeling by each subunit: the molecular weights of the three bands (106K, 88K, and 83K) produced by the subunit are larger by approximately 10K than those of the three bands (96K, 76K, and 73K) labeled by the ..cap alpha.. subunit. Although it could be a coincidence that the molecular weight of the ..beta.. subunit is approximately 10K larger thanmore » that of the ..cap alpha.. subunit, the similarity in these differences suggests the possibility that both the ..cap alpha.. and ..beta.. subunits have labeled the same polypeptides.« less

  4. Vertically integrated (Ga, In)N nanostructures for future single photon emitters operating in the telecommunication wavelength range

    NASA Astrophysics Data System (ADS)

    Winden, A.; Mikulics, M.; Grützmacher, D.; Hardtdegen, H.

    2013-10-01

    Important technological steps are discussed and realized for future room-temperature operation of III-nitride single photon emitters. First, the growth technology of positioned single pyramidal InN nanostructures capped by Mg-doped GaN is presented. The optimization of their optical characteristics towards narrowband emission in the telecommunication wavelength range is demonstrated. In addition, a device concept and technology was developed so that the nanostructures became singularly addressable. It was found that the nanopyramids emit in the telecommunication wavelength range if their size is chosen appropriately. A p-GaN contacting layer was successfully produced as a cap to the InN pyramids and the top p-contact was achievable using an intrinsically conductive polymer PEDOT:PSS, allowing a 25% increase in light transmittance compared to standard Ni/Au contact technology. Single nanopyramids were successfully integrated into a high-frequency device layout. These decisive technology steps provide a promising route to electrically driven and room-temperature operating InN based single photon emitters in the telecommunication wavelength range.

  5. Differentiation to adipocytes in accompanied by an increase in the amounts of Gi- and Go-proteins in 3T3-L1 cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Watkins, D.C.; Northup, J.K.; Malbon, C.C.

    Treatment of cultures of 3T3-L1 cells with methylisobutyl-xanthine and dexamethasone has been shown to result in accumulation of lipid and conversion to the morphology of adipocytes in more than 90% of the cells. The status of the stimulatory (Gs), inhibitory (Gi) and Go-proteins during the course of 3T3-L1 differentiation was examined. The amount of alpha subunit of Gs (..cap alpha..Gs), assayed by radiolabeling in the presence of cholera toxin and (/sup 32/P)NAD/sup +/, increased upon differentiation as previously described by others. The amounts of ..cap alpha..Gi and ..cap alpha..Go assayed by radiolabeling in the presence of pertussis toxin and (/supmore » 32/P)NAD/sup +/ increased 3-fold upon differentiation. Immunoblots of cell membranes subjected to gel electrophoresis in sodium dodecyl sulfate were probed with two rabbit antisera raised against bovine brain ..cap alpha..Go and with one raised against the..beta..-subunit of the bovine rod-outer-segment G-protein, referred to as transducin. The immunoblotting data confirm the increase upon differentiation of ..cap alpha..Go and also demonstrate an increase in the amount of the ..beta..-subunit. Thus differentiation of 3T3-L1 cells is accompanied by dramatic changes in the complexion of G-proteins in the membranes.« less

  6. cap alpha. /sub 2/-Adrenergic receptor-mediated sensitization of forskolin-stimulated cyclic AMP production

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, S.B.; Toews, M.L.; Turner, J.T.

    1987-03-01

    Preincubation of HT29 human colonic adenocarcinoma cells with ..cap alpha../sub 2/-adrenergic agonists resulted in a 10- to 20-fold increase in forskolin-stimulated cyclic AMP production as compared to cells preincubated without agonist. Similar results were obtained using either a (/sup 3/H)adenine prelabeling assay or a cyclic AMP radioimmunoassay to measure cyclic AMP levels. This phenomenon, which is termed sensitization, is ..cap alpha../sub 2/-adrenergic receptor-mediated and rapid in onset and reversal. Yohimbine, an ..cap alpha../sub 2/-adrenergic receptor-selective antagonist, blocked norepinephrine-induced sensitization, whereas prazosin (..cap alpha../sub 1/-adrenergic) and sotalol (..beta..-adrenergic) did not. The time for half-maximal sensitization was 5 min and the half-timemore » for reversal was 10 min. Only a 2-fold sensitization of cyclic AMP production stimulated by vasoactive intestinal peptide was observed, indicating that sensitization is relatively selective for forskolin. Sensitization reflects an increased production of cyclic AMP and not a decreased degradation of cyclic AMP, since incubation with a phosphodiesterase inhibitor and forskolin did not mimic sensitization. Increasing the levels of cyclic AMP during the preincubation had no effect on sensitization, indicating that sensitization is not caused by decreased cyclic AMP levels during the preincubation. This rapid and dramatic sensitization of forskolin-stimulated cyclic AMP production is a previously unreported effect that can be added to the growing list of ..cap alpha../sub 2/-adrenergic responses that are not mediated by a decrease in cyclic AMP.« less

  7. Measuring Beam Sizes and Ultra-Small Electron Emittances Using an X-ray Pinhole Camera.

    PubMed

    Elleaume, P; Fortgang, C; Penel, C; Tarazona, E

    1995-09-01

    A very simple pinhole camera set-up has been built to diagnose the electron beam emittance of the ESRF. The pinhole is placed in the air next to an Al window. An image is obtained with a CCD camera imaging a fluorescent screen. The emittance is deduced from the size of the image. The relationship between the measured beam size and the electron beam emittance depends upon the lattice functions alpha, beta and eta, the screen resolution, pinhole size and photon beam divergence. The set-up is capable of measuring emittances as low as 5 pm rad and is presently routinely used as both an electron beam imaging device and an emittance diagnostic.

  8. MOLECULAR SIEVES ADSORB IODINE-131 FROM AIR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wahlgren, M.A.; Meinke, W.W.

    1957-09-01

    Consideration has been given to the problem of separating and estimating U, Po, nnd other alpha emitters (in order to provide analytical methods for their routine determination in conformity with the draft agreement on the Harwell effluent). Uranium may be ether extracted from solutions of NH/sub 4/NO/sub 3/ as salting out agent at pH1 with an efficiency of 98 to 99%. The deposition of Po on Ag foil is a specific method for this element and under prescribed conditions similar extraction efficiencies may be obtained. An adequate separation from all "other alpha emitters" is obtained and methods for the estimationmore » of these are discussed. A comprehensive scheme involving a preliminary activity concentration step has been elaborated. U, Po, and the majority of the "other alpha emitters" are precipitated as their tannin complexes at pH8 using Ca(OH)/sub 2/, the calcium-tannin complex acting as a carrier. That part of the activity remaining in solution is determined as in the total activity method, previously described. From the solution of the precipitate, Po is first separated by electrodeposition, and then U by ether extraction in the presence of NH/sub 4/NO/sub 3/. The majority of the "other alpha emitters" still in the aqueous NH/sub 4/NO/sub 3/ solution are collected on a second calcium-tannin precipitate, while the small part remaining in solution after this operation is obtained by direct evaporation. (auth)« less

  9. Role of a guanine nucleotide-binding protein in. cap alpha. /sub 1/-adrenergic receptor-mediated Ca/sup 2 +/ mobilization in DDT/sub 1/ MF-2 cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cornett, L.E.; Norris, J.S.

    1987-11-01

    In this study the mechanisms involved in ..cap alpha../sub 1/-adrenergic receptor-mediated Ca/sup 2 +/ mobilization at the level of the plasma membrane were investigated. Stimulation of /sup 45/Ca/sup 2 +/ efflux from saponin-permeabilized DDT/sub 1/ MF-2 cells was observed with the addition of either the ..cap alpha../sub 1/-adrenergic agonist phenylephrine and guanosine-5'-triphosphate or the nonhydrolyzable guanine nucleotide guanylyl-imidodiphosphate. In the presence of (/sup 32/P) NAD, pertussis toxin was found to catalyze ADP-ribosylation of a M/sub r/ = 40,500 (n = 8) peptide in membranes prepared from DDT/sub 1/, MF-2 cells, possibly the ..cap alpha..-subunit of N/sub i/. However, stimulation ofmore » unidirectional /sup 45/Ca/sup 2 +/ efflux by phenylephrine was not affected by previous treatment of cells with 100 ng/ml pertussis toxin. These data suggest that the putative guanine nucleotide-binding protein which couples the ..cap alpha../sub 1/-adrenergic receptor to Ca/sup 2 +/ mobilization in DDT/sub 1/ MF-2 cells is not a pertussis toxin substrate and may possibly be an additional member of guanine nucleotide binding protein family.« less

  10. Source brightness and useful beam current of carbon nanotubes and other very small emitters

    NASA Astrophysics Data System (ADS)

    Kruit, P.; Bezuijen, M.; Barth, J. E.

    2006-01-01

    The potential application of carbon nanotubes as electron sources in electron microscopes is analyzed. The resolution and probe current that can be obtained from a carbon nanotube emitter in a low-voltage scanning electron microscope are calculated and compared to the state of the art using Schottky electron sources. Many analytical equations for probe-size versus probe-current relations in different parameter regimes are obtained. It is shown that for most carbon nanotube emitters, the gun lens aberrations are larger than the emitters' virtual source size and thus restrict the microscope's performance. The result is that the advantages of the higher brightness of nanotube emitters are limited unless the angular emission current is increased over present day values or the gun lens aberrations are decreased. For some nanotubes with a closed cap, it is known that the emitted electron beam is coherent over the full emission cone. We argue that for such emitters the parameter ``brightness'' becomes meaningless. The influence of phase variations in the electron wave front emitted from such a nanotube emitter on the focusing of the electron beam is analyzed.

  11. Extending lifetimes of lanthanide-based near-infrared emitters (Nd, Yb) in the millisecond range through Cr(III) sensitization in discrete bimetallic edifices.

    PubMed

    Imbert, Daniel; Cantuel, Martine; Bünzli, Jean-Claude G; Bernardinelli, Gérald; Piguet, Claude

    2003-12-24

    A [Cr(alpha,alpha'-diimine)3]3+ chromophore is used as a donor for sensitizing NdIII and YbIII near-infrared (NIR) emitters in the heterobimetallic helicates [LnCrIIIL3]6+. The intramolecular CrIII --> LnIII energy transfer process controls the population of the lanthanide-centered emitting levels, thus leading to unprecedented extension of the NIR luminescence decay times in the millisecond range for Nd and Yb ions incorporated in coordination complexes.

  12. E2C mechanism of elimination reactions. IX. Secondary deuterium isotope effects on rates of bimolecular reactions in alicyclic systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cook, D.

    1976-06-11

    Secondary ..cap alpha..-deuterium isotope effects on the rates of NBu/sub 4/OAc and NBu/sub 4/Cl promoted bimolecular reactions (E2 and SN2) of cyclohexyl tosylate and cyclohexyl bromide have been studied. The E2 reactions, previously categorized as E2C-like, show ..cap alpha..-deuterium isotope effects in the range 1.14--1.22, while the related SN2 reactions give values in the range 1.05--1.08. The discrepancy in the magnitude of the ..cap alpha..-deuterium isotope effect for the E2 and SN2 processes is consistent with the view that E2C-like reactions use ''looser'' transition states than those used in the concurrent SN2 reactions. While the reported ..cap alpha..-d isotope effectsmore » do not provide positive evidence to support the idea that the base interacts with C/sub ..cap alpha../ in the E2 transition states of the reactions studied, neither do they substantiate claims for dismissal of the concept. A comparison of the secondary ..gamma..-deuterium and ..beta..'-deuterium isotope effects arising in the reaction of cyclohexyl tosylate with NBu/sub 4/OAc in acetone indicates the two isotope effects to be of equivalent magnitude (k/sub ..beta..'-d/k/sub ..gamma..-d/ = 0.98). This observation can only be rationalized for this reaction in terms of a transition state structure in which there is extensive double bond development. It provides compelling evidence against the involvement of any transition state structure which accommodates extensive positive charge development at C/sub ..cap alpha../.« less

  13. High-absorptance high-emittance anodic coating

    NASA Technical Reports Server (NTRS)

    Le, Huong Giang (Inventor); Chesterfield, John L. (Inventor)

    1999-01-01

    A colored anodic coating for use on surfaces of substrates, e.g. aluminum substrates in which it is desirable to maintain a high solar absorptance (.alpha.) and a high infrared emittance (.epsilon.), particularly in low earth orbit space environments. This anodic coating is preferably a dark colored coating, and even more preferably a black coating. This coating allows a touch temperature within an acceptable design range to preclude burning of an astronaut in case of contact, but also allows a solar radiation absorption in an amount such that an .alpha./.epsilon. ratio of unity is achieved. The coating of the invention comprises a first layer in the form of an acid anodized colored anodic layer for achieving a high solar absorptance and a second or high emittance layer in the form of a clear acid anodized layer for achieving a high emittance. The entire coating is quite thin, e.g. 1-2 mils and is quite stable in a hostile space environment of the type encountered in a low earth orbit. The coating is obtained by first creating the high emittance clear anodized coating on the metal surface followed by anodizing using a colored anodizing process.

  14. Variable Emittance Electrochromics Using Ionic Electrolytes and Low Solar Absorptance Coatings

    NASA Technical Reports Server (NTRS)

    Chandrasekhar, Prasanna

    2011-01-01

    One of the last remaining technical hurdles with variable emittance devices or skins based on conducting polymer electrochromics is the high solar absorptance of their top surfaces. This high solar absorptance causes overheating of the skin when facing the Sun in space. Existing technologies such as mechanical louvers or loop heat pipes are virtually inapplicable to micro (< 20 kg) and nano (< 5 kg) spacecraft. Novel coatings lower the solar absorption to Alpha(s) of between 0.30 and 0.46. Coupled with the emittance properties of the variable emittance skins, this lowers the surface temperature of the skins facing the Sun to between 30 and 60 C, which is much lower than previous results of 100 C, and is well within acceptable satellite operations ranges. The performance of this technology is better than that of current new technologies such as microelectromechanical systems (MEMS), electrostatics, and electrophoretics, especially in applications involving micro and nano spacecraft. The coatings are deposited inside a high vacuum, layering multiple coatings onto the top surfaces of variable emittance skins. They are completely transparent in the entire relevant infrared region (about 2 to 45 microns), but highly reflective in the visible-NIR (near infrared) region of relevance to solar absorptance.

  15. Alpha particle effects in burning tokamak plasmas: overview and specific examples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sigmar, D.J.

    1986-07-01

    Using the total power balance of an ignited tokamak plasma as a guideline, a range of alpha driven effects is surveyed regarding their impact on achieving and maintaining fusion burn. Specific examples of MHD and kinetic modes and multi species transport dynamics are discussed, including the possible interaction of these categories of effects. This power balance approach rather than a straightforward enumeration of possible effects serves to reveal their non-linear dependence and the ensuing fragility of our understanding of the approach to and maintenance of ignition. Specific examples are given of the interaction between ..cap alpha..-power driven sawtoothing and idealmore » MHD stability, and direct ..cap alpha..-effects on MHD modes including kinetic corrections. Anomalous ion heat transport and central impurity peaking mechanisms and anomalous and collisional ..cap alpha..-transport including the ambipolar electric field are discussed.« less

  16. Beta/alpha continuous air monitor

    DOEpatents

    Becker, Gregory K.; Martz, Dowell E.

    1989-01-01

    A single deep layer silicon detector in combination with a microcomputer, recording both alpha and beta activity and the energy of each pulse, distinguishing energy peaks using a novel curve fitting technique to reduce the natural alpha counts in the energy region where plutonium and other transuranic alpha emitters are present, and using a novel algorithm to strip out radon daughter contribution to actual beta counts.

  17. Alpha/beta pulse shape discrimination in plastic scintillation using commercial scintillation detectors.

    PubMed

    Bagán, H; Tarancón, A; Rauret, G; García, J F

    2010-06-18

    Activity determination in different types of samples is a current need in many different fields. Simultaneously analysing alpha and beta emitters is now a routine option when using liquid scintillation (LS) and pulse shape discrimination. However, LS has an important drawback, the generation of mixed waste. Recently, several studies have shown the capability of plastic scintillation (PS) as an alternative to LS, but no research has been carried out to determine its capability for alpha/beta discrimination. The objective of this study was to evaluate the capability of PS to discriminate alpha/beta emitters on the basis of pulse shape analysis (PSA). The results obtained show that PS pulses had lower energy than LS pulses. As a consequence, a lower detection efficiency, a shift to lower energies and a better discrimination of beta and a worst discrimination of alpha disintegrations was observed for PS. Colour quenching also produced a decrease in the energy of the particles, as well as the effects described above. It is clear that in PS, the discrimination capability was correlated with the energy of the particles detected. Taking into account the discrimination capabilities of PS, a protocol for the measurement and the calculation of alpha and beta activities in mixtures using PS and commercial scintillation detectors has been proposed. The new protocol was applied to the quantification of spiked river water samples containing a pair of radionuclides ((3)H-(241)Am or (90)Sr/(90)Y-(241)Am) in different activity proportions. The relative errors in all determinations were lower than 7%. These results demonstrate the capability of PS to discriminate alpha/beta emitters on the basis of pulse shape and to quantify mixtures without generating mixed waste. 2010 Elsevier B.V. All rights reserved.

  18. The electric potential of particles in interstellar space released from a nuclear waste payload

    NASA Technical Reports Server (NTRS)

    Williams, A. C.

    1980-01-01

    Mechanisms for charging a grain in the interplanetary medium include: (1) capture of solar wind electrons; (2) capture of solar wind protons; (3) ejection of electrons through the photoelectric effect due to the solar radiation; (4) escape of beta particles from beta emitters in the grain; and (5) escape of alpha particles from alpha emitters in the grain. The potentials on both nonradioactive and radioactive grains are considered with relation to particle size and time, and the distance from the Sun. Numerical results are presented where the waste mix is assumed to be PW-4b.

  19. Beta/alpha continuous air monitor

    DOEpatents

    Becker, G.K.; Martz, D.E.

    1988-06-27

    A single deep layer silicon detector in combination with a microcomputer, recording both alpha and beta activity and the energy of each pulse, distinquishing energy peaks using a novel curve fitting technique to reduce the natural alpha counts in the energy region where plutonium and other transuranic alpha emitters are present, and using a novel algorithm to strip out radon daughter contribution to actual beta counts. 7 figs.

  20. Highly excited states in /sup 6/Li by the reaction /sup 9/Be(p,. cap alpha. )/sup 6/Li. [Width of 8. 2-MeV level

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Delbar, T.; Gregoire, G.; Lega, J.

    1976-10-01

    The spectra from the reaction /sup 9/Be(p, ..cap alpha..)/sup 6/Li induced by 75 and 30 MeV protons were recorded at theta/sub ..cap alpha../ = 20 and 30/sup 0/ in the laboratory frame. The region from 6 to 18 MeV excitation energy of the residual nucleus was carefully studied for possible levels. Evidence for a T = 1 level at E/sub x/ = 8.2 +- 0.2 MeV with a width GAMMA = 2.2 +- 0.2 MeV is reported. No other levels were observed in the present spectra. (AIP)

  1. A novel method for rapid in vitro radiobioassay

    NASA Astrophysics Data System (ADS)

    Crawford, Evan Bogert

    Rapid and accurate analysis of internal human exposure to radionuclides is essential to the effective triage and treatment of citizens who have possibly been exposed to radioactive materials in the environment. The two most likely scenarios in which a large number of citizens would be exposed are the detonation of a radiation dispersal device (RDD, "dirty bomb") or the accidental release of an isotope from an industrial source such as a radioisotopic thermal generator (RTG). In the event of the release and dispersion of radioactive materials into the environment in a large city, the entire population of the city -- including all commuting workers and tourists -- would have to be rapidly tested, both to satisfy the psychological needs of the citizens who were exposed to the mental trauma of a possible radiation dose, and to satisfy the immediate medical needs of those who received the highest doses and greatest levels of internal contamination -- those who would best benefit from rapid, intensive medical care. In this research a prototype rapid screening method to screen urine samples for the presence of up to five isotopes, both individually and in a mixture, has been developed. The isotopes used to develop this method are Co-60, Sr-90, Cs-137, Pu-238, and Am-241. This method avoids time-intensive chemical separations via the preparation and counting of a single sample on multiple detectors, and analyzing the spectra for isotope-specific markers. A rapid liquid-liquid separation using an organic extractive scintillator can be used to help quantify the activity of the alpha-emitting isotopes. The method provides quantifiable results in less than five minutes for the activity of beta/gamma-emitting isotopes when present in the sample at the intervention level as defined by the Centers for Disease Control and Prevention (CDC), and quantifiable results for the activity levels of alpha-emitting isotopes present at their respective intervention levels in approximately 30 minutes of sample preparation and counting time. Radiation detector spectra -- e.g. those from high-purity germanium (HPGe) gamma detectors and liquid scintillation detectors -- which contain decay signals from multiple isotopes often have overlapping signals: the counts from one isotope's decay can appear in energy channels associated with another isotope's decay, complicating the calculation of each isotope's activity. The uncertainties associated with analyzing these spectra have been traced in order to determine the effects of one isotope's count rate on the sensitivity and uncertainty associated with each other isotope. The method that was developed takes advantage of activated carbon filtration to eliminate quenching effects and to make the liquid scintillation spectra from different urine samples comparable. The method uses pulse-shape analysis to reduce the interference from beta emitters in the liquid scintillation spectrum and improve the minimum detectable activity (MDA) and minimum quantifiable activity (MQA) for alpha emitters. The method uses an HPGe detector to quantify the activity of gamma emitters, and subtract their isotopes' contributions to the liquid scintillation spectra via a calibration factor, such that the pure beta and pure alpha emitters can be identified and quantified from the resulting liquid scintillation spectra. Finally, the method optionally uses extractive scintillators to rapidly separate the alpha emitters from the beta emitters when the activity from the beta emitters is too great to detect or quantify the activity from the alpha emitters without such a separation. The method is able to detect and quantify all five isotopes, with uncertainties and biases usually in the 10-40% range, depending upon the isotopic mixtures and the activity ratios between each of the isotopes.

  2. Comparisons of carcinogenicities of nickel compounds in rats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sunderman, F.W. Jr.; Maenza, R.M.

    This study demonstrates marked differences in the incidences of sarcomas in Fischer rats within 2 years after a single im injection of 4 insoluble nickel-containing powders amorphous nickel monosulfide (NiS), nickel subsulfide (..cap alpha..Ni/sub 3/S/sub 2/), partially converted nickel-iron sulfide matte, and metallic nickel. The powders (<2 ..mu..m median particle diameters) were administered in penicillin suspension, and each powder was tested at 2 dosages. Whereas ..cap alpha..Ni/sub 3/S/sub 2/ was highly carcinogenic, amorphous NiS did not induce any tumors. The carcinogenic potency of partially converted nickel-iron sulfide matte was less than ..cap alpha..Ni/sub 3/S/sub 2/ but greater than Ni powder.more » No sarcomas occurred at the injection site in two groups of control rats that received im injections of penicillin or Fe powder. The observed differences in carcinogenic potencies of ..cap alpha..Ni/sub 3/S/sub 2/ and amorphous NiS may provide an experimental approach to elucidate the molecular mechanisms of nickel carcinogenesis.« less

  3. Hydrophobic interactions in complexes of antimicrobial peptides with bacterial polysaccharides.

    PubMed

    Kuo, Hsin H; Chan, Celine; Burrows, Lori L; Deber, Charles M

    2007-06-01

    Biofilms of Pseudomonas aeruginosa are responsible for chronic lung infections in cystic fibrosis patients, where they are characterized by overproduction of the exopolysaccharide alginate and are recalcitrant to treatment with conventional antibiotics. Cationic antimicrobial peptides (CAPs) are potential alternatives for the treatment of multi-drug-resistant P. aeruginosa. However, alginate in P. aeruginosa biofilms has been proposed to bind these peptides through hydrophobic interactions, consequently reducing their activity [Chan et al., J Biol Chem 2004; 279: 38749-38754]. Here we perform biophysical analyses of the interactions of alginate with a series of novel peptide antibiotics (alpha-CAPs) of prototypic sequence KK-AAAXAAAAAXAAWAAXAAA-KKKK (where X = Phe, Trp or Leu). The hydrophobic interaction interface in alginate was investigated by examining (i) the effects of polysaccharide composition with respect to D-mannuronate and L-guluronate content; (ii) glycan chain length; (iii) alpha-CAP Trp fluorescence; and (iv) 1-anilinonaphthalene-8-sulfonate fluorescence. The results show that, while M and G residues produce equivalent effects, hydrophobic interactions between alginate and alpha-CAPs require a minimal glycan chain length. Peptide interactions with alginate are deduced to be mediated by hydrophobic microdomains comprised of pyranosyl C-H groups that are inducible upon formation of alpha-CAP-alginate complexes due to charge neutralization between the two species.

  4. Dissimilar effects of chronic treatment with aspirin, flubiprofen and indomethacin on renal prostaglandins

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Quilley, C.P.; McGiff, J.C.; Quilley, J.

    Inhibition of prostaglandin (PG) excretion is not sustained during long-term aspirin administration. The authors compared the effects of 9d treatment of SHR rats with aspirin (A), 200 mg/kg/d s.c., flubiprofen (F), 2.5 mg/kg/12h s.c., and indomethacin (I), 2.5 mg/kg/12 s.c. on excretion of radioimmunoassayable PGE/sub 2/ and PGF/sub 2..cap alpha../. Conversion of 1-(/sup 14/C) arachidonic acid (AA) by renal papillae was also examined. In vehicle-treated control rats (C) PGF/sub 2..cap alpha../ excretion varied from 32.2 +/- 6.2 (mean +/- SEM) to 41.6 +.- 7.3 ng/6h, 3-fold higher than that of PGE/sub 2/. Within 6h of administration all 3 drugs reducedmore » excretion of PGF/sub 2..cap alpha../ and PGE/sub 2/ to less than 20% and 35% of C rats. Although urinary concentrations of PGF/sub 2..cap alpha../ and PGE/sub 2/ in A-treated rats remained depressed, a 2-fold increase in urine volume resulted in excretion rates similar to C rats. In contrast, urine volume in I- and F-treated rats was unaffected while PGF/sub 2..cap alpha../ and PGE/sub 2/ excretion rates in I-treated rats were 50''% of C rats and were also lower than control in F-treated rats. Paradoxically, metabolism of AA to PGs by by renal papillae dissected on day 10, 2-4h after the last drug dose, was markedly inhibited by A (PGF/sub 2..cap alpha../ by 62% and PGE/sub 2/ by 82%), but unaffected by I and F. As the effects of cyclooxygenase inhibitors differ on in vivo and indices of PG production, their intended action should be verified by measuring PG levels in biological fluids.« less

  5. Non-linear vacuum polarization in strong fields

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gyulassy, M.

    1981-07-01

    The Wichmann-Kroll formalism for calculating the vacuum polarization density to first order in ..cap alpha.. but to all orders in Z..cap alpha.. is derived. The most essential quantity is shown to be the electrons Green's function in these calculations. The method of constructing that Green's function in the field of finite radius nuclei is then presented.

  6. Metabolism of. cap alpha. -C/sup 14/-histidine in the intact rat. II. Radioactive excretion products in urine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wolf, G.; Wu, P.H.L.; Heck, W.W.

    1956-09-01

    The normal metabolic pathways in the intact rat was investigated via the radioactive urinary excretion products following administration of a physiological dose of a radioactive compound such as ..cap alpha..-C/sup 14/-DL-histidine. The major metabolites, except one, excreted in the urine 5 hours after administration of ..cap alpha..-C/sup 14/-DL-histidine were isolated and identified. Glutamic acid and urocanic acids had simlar and low activities, whereas carboxyl-labeled imidazoacetic acid was found to be the principal metabolite with a high level of activity. It was concluded that the main end-product of the catabolism of DL-histidine is imidazoleacetic acid probably formed through imidazolepyruvic acid.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weinstein, L.; Droegemueller, W.; Cornette, J.

    A single intra-amniotic injection of (15S)-15 methyl prostaglandin F/sub 2/..cap alpha.. (THAM) was used to induce second trimester abortion in five patients. Serial levels of (15S)-15 methyl prostaglandin F/sub 2/..cap alpha.. were subsequently measured in amniotic fluid and plasma by radioimmunoassay. The slow removal of this drug from the amniotic fluid was documented. Plasma levels of (15S)-15 methyl prostaglandin F/sub 2/..cap alpha.. increased fourfold to sevenfold after clinical rupture of the membranes in three patients, supporting the fact that prostaglandins are well absorbed from the vagina. Because this analogue of prostaglandin can cause marked peripheral bronchoconstriction when administered systemically, itmore » is best to avoid its use in patients with a history of asthma.« less

  8. Self-modulating pressure gauge

    DOEpatents

    Edwards, D. Jr.; Lanni, C.P.

    1979-08-07

    An ion gauge is disclosed having a reduced x-ray limit and means for measuring that limit. The gauge comprises an ion gauge of the Bayard-Alpert type having a short collector and having means for varying the grid-collector voltage. The x-ray limit (i.e. the collector current resulting from x-rays striking the collector) may then be determined by the formula: I/sub x/ = ..cap alpha..I/sub l/ - I/sub h//..cap alpha.. - l where: I/sub x/ = x-ray limit, I/sub l/ and I/sub h/ = the collector current at the lower and higher grid voltage respectively; and, ..cap alpha.. = the ratio of the collector current due to positive ions at the higher voltage to that at the lower voltage.

  9. A Search for z>6.5 Lyman-alpha Emitting Galaxies with WISP

    NASA Astrophysics Data System (ADS)

    Bagley, Micaela B.; Scarlata, Claudia; Dai, Yu Sophia; Rafelski, Marc; Baronchelli, Ivano; Colbert, James W.; Dominguez, Alberto; Hathi, Nimish P.; Henry, Alaina L.; Malkan, Matthew Arnold; Martin, Crystal L.; Mehta, Vihang; Pahl, Anthony; Ross, Nathaniel; Rutkowski, Michael J.; Teplitz, Harry I.; WISP Team

    2016-01-01

    The observed number density of Lyman-alpha emitting galaxies at z>6 provides an important probe of the reionization history of the universe. Because Lyman-alpha photons are very sensitive to the presence of neutral hydrogen, the evolution of the galaxy number density above redshift 6 can be used as a measurement on the progress of reionization. However, the Lyman-alpha luminosity function is currently poorly constrained at high-z. We present the results of a systematic search for Lyman-alpha emitters (LAEs) at redshifts of ~6.5 to 7.5 using the HST WFC3 Infrared Spectroscopic Parallels (WISP) survey. WISP's uncorrelated fields are well-suited to the study of bright LAEs, minimizing the effects of clustering introduced by a patchy reionization. From the 30 deepest WISP fields, we compile a sample of single-line emitters, confirm redshifts with broadband colors, and identify LAE candidates that have "dropped out" (are undetected at the 1 sigma level) of the WFC3 UVIS filters. By combining our results with other z~7 studies, we determine whether the number density of LAEs evolves past z~6.5.

  10. Dynamic radioactive particle source

    DOEpatents

    Moore, Murray E; Gauss, Adam Benjamin; Justus, Alan Lawrence

    2012-06-26

    A method and apparatus for providing a timed, synchronized dynamic alpha or beta particle source for testing the response of continuous air monitors (CAMs) for airborne alpha or beta emitters is provided. The method includes providing a radioactive source; placing the radioactive source inside the detection volume of a CAM; and introducing an alpha or beta-emitting isotope while the CAM is in a normal functioning mode.

  11. A NOVEL TECHNIQUE FOR THE RAPID IDENTIFICATION OF ALPHA EMITTERS RELEASED DURING A RADIOLOGICAL INCIDENT.

    EPA Science Inventory

    Currently there are no standard radioanalytical methods applicable to the initial phase of a radiological emergency, for the early identification and quantification of alpha emitting radionuclides. Of particular interest are determinations of the presence and concentration of is...

  12. Sharing global CO2 emission reductions among one billion high emitters

    PubMed Central

    Chakravarty, Shoibal; Chikkatur, Ananth; de Coninck, Heleen; Pacala, Stephen; Socolow, Robert; Tavoni, Massimo

    2009-01-01

    We present a framework for allocating a global carbon reduction target among nations, in which the concept of “common but differentiated responsibilities” refers to the emissions of individuals instead of nations. We use the income distribution of a country to estimate how its fossil fuel CO2 emissions are distributed among its citizens, from which we build up a global CO2 distribution. We then propose a simple rule to derive a universal cap on global individual emissions and find corresponding limits on national aggregate emissions from this cap. All of the world's high CO2-emitting individuals are treated the same, regardless of where they live. Any future global emission goal (target and time frame) can be converted into national reduction targets, which are determined by “Business as Usual” projections of national carbon emissions and in-country income distributions. For example, reducing projected global emissions in 2030 by 13 GtCO2 would require the engagement of 1.13 billion high emitters, roughly equally distributed in 4 regions: the U.S., the OECD minus the U.S., China, and the non-OECD minus China. We also modify our methodology to place a floor on emissions of the world's lowest CO2 emitters and demonstrate that climate mitigation and alleviation of extreme poverty are largely decoupled. PMID:19581586

  13. Fabrication, characterization and simulation of 4H-SiC Schottky diode alpha particle detectors for pyroprocessing actinide monitoring

    NASA Astrophysics Data System (ADS)

    Garcia, Timothy Richard

    Pyroprocessing is a method of using high-temperature molten salts and electric fields to separate and collect fuel isotopes of used nuclear fuel. It has been has been tested in the U.S. at Idaho National Laboratory as a key step in closing the nuclear fuel cycle. One technical problem with the pyroprocessing method is a lack of knowledge regarding the actinide concentrations in the salt bath during operation, since on-line techniques for measuring these concentrations are not presently available. 4H-SiC Schottky diode detectors can potentially fulfill this need. Such detectors would operate in contact with the molten salt, and measure concentrations via alpha-particle spectroscopy. This work seeks to fabricate and characterize 4H-SiC Schottky diode detectors at high temperature, model the alpha particle spectrum expected in a molten salt, and model the operation of the detectors to confirm the physics of operation is as expected. In this work, 4H-SiC Schottky diode detectors were fabricated at OSU Nanotech West. After fabrication, these detectors were characterized using both I-V curves and Am-241 alpha-particle energy spectra. All measurements were made as a function of temperature, from room temperature up to 500°C. The average energy required to create an electron-hole pair was observed to decrease with an increase of temperature, due to a decrease of both the 4H-SiC bandgap and non-linear energy loss terms. Furthermore, the FWHM of the spectra was observed to be dependent on the leakage current at a certain temperature, and not dependent on the temperature itself. Secondly, the alpha particle energy spectrum in the pyroprocessing environment was modeled using SRIM. The molten salt was modeled in 3 different geometries, with or without a protective cover material on top of the detector. Due to the loss of alpha-particle energy in the molten salt itself, a high-energy alpha emitter may completely cover the spectrum from a lower-energy alpha emitter. Each of the geometries simulated showed a different sensitivity to the lower-energy alpha emitter. Regardless of which geometry was modeled, it was observed that it is possible to measure both the emission energy of the alpha particles, as well as the concentration of the alpha emitter in the liquid. Lastly, Sentaurus TCAD was used to simulate the detection of alpha-particle charge collection in situations that are relevant to the molten salt alpha particle energy spectra. The effect of electric field negation was investigated, as well as velocity saturation. Finally, the dependence of charge recombination on temperature, alpha particle energy, and angle of incidence was investigated. These simulations captured the measurements performed at room temperature. With changed angle of incidence, the change in the amount of charge collected was less than 1 percent, indicating a weak dependence. Also, the amount of charge lost to Auger recombination was seen to increase with temperature. This disagrees with observations from experiment, indicating that the temperature dependence of one or more parameters of the model may not be accurate.

  14. Predicting the Redshift 2 H-Alpha Luminosity Function Using [OIII] Emission Line Galaxies

    NASA Technical Reports Server (NTRS)

    Mehta, Vihang; Scarlata, Claudia; Colbert, James W.; Dai, Y. S.; Dressler, Alan; Henry, Alaina; Malkan, Matt; Rafelski, Marc; Siana, Brian; Teplitz, Harry I.; hide

    2015-01-01

    Upcoming space-based surveys such as Euclid and WFIRST-AFTA plan to measure Baryonic Acoustic Oscillations (BAOs) in order to study dark energy. These surveys will use IR slitless grism spectroscopy to measure redshifts of a large number of galaxies over a significant redshift range. In this paper, we use the WFC3 Infrared Spectroscopic Parallel Survey (WISP) to estimate the expected number of H-alpha emitters observable by these future surveys. WISP is an ongoing Hubble Space Telescope slitless spectroscopic survey, covering the 0.8 - 1.65 micrometers wavelength range and allowing the detection of H-alpha emitters up to z approximately equal to 1.5 and [OIII] emitters to z approximately equal to 2.3. We derive the H-alpha-[OIII] bivariate line luminosity function for WISP galaxies at z approximately equal to 1 using a maximum likelihood estimator that properly accounts for uncertainties in line luminosity measurement, and demonstrate how it can be used to derive the H-alpha luminosity function from exclusively fitting [OIII] data. Using the z approximately equal to 2 [OIII] line luminosity function, and assuming that the relation between H-alpha and [OIII] luminosity does not change significantly over the redshift range, we predict the H-alpha number counts at z approximately equal to 2 - the upper end of the redshift range of interest for the future surveys. For the redshift range 0.7 less than z less than 2, we expect approximately 3000 galaxies per sq deg for a flux limit of 3 x 10(exp -16) ergs per sec per sq cm (the proposed depth of Euclid galaxy redshift survey) and approximately 20,000 galaxies per sq deg for a flux limit of approximately 10(exp -16) ergs per sec per sq cm (the baseline depth of WFIRST galaxy redshift survey).

  15. Internode length in Pisum. Gene na may block gibberellin synthesis between ent-7. cap alpha. -hydroxykaurenoic acid and biggerellin A/sub 12/-aldehyde. [Pisum sativum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ingram, T.J.; Reid, J.B.

    1987-04-01

    The elongation response of the gibberellin (GA) deficient genotypes na, ls, and lh of peas (Pisum sativum L.) to a range of GA-precursors was examined. Plants possessing gene na did not respond to precursors in the GA biosynthetic pathway prior to GA/sub 12/-aldehyde. In contrast, plants possessing lh and ls responded as well as wild-type plants (dwarfed with AMO-1618) to these compounds. The results suggest that GA biosynthesis is blocked prior to ent-kaurene in the lh and ls mutants and between ent-7..cap alpha..-hydroxykaurenoic acid and GA/sub 12/-aldehyde in the na mutant. Feeds of ent(/sup 3/H)kaurenoic acid and (/sup 2/H)GA/sub 12/-aldehydemore » to a range of genotypes supported the above conclusions. The na line WL1766 was shown by gas chromatography-mass spectrometry (GC-MS) to metabolize(/sup 2/H)GA/sub 12/-aldehyde to a number of (/sup 2/H)C/sub 19/-GAs including GA/sub 1/. However, there was no indication in na genotypes for the metabolism of ent-(/sup 3/H)kaurenoic acid to these GAs. In contrast, the expanding shoot tissue of all Na genotypes examined metabolized ent-(/sup 3/H)kaurenoic acid to radioactive compounds that co-chromatographed with GA/sub 1/, GA/sub 8/, GA/sub 20/, and GA/sub 29/. However, insufficient material was present for unequivocal identification of the metabolites. The radioactive profiles from HPLC of extracts of the node treated with ent-(/sup 3/H)kaurenoic acid were similar for both Na and na plants and contained ent-16..cap alpha..,17-dihydroxykaurenoic acid and ent-6..cap alpha..,7..cap alpha..,16..beta..,17-tetrahydroxykaurenoic acid (both characterized by GC-MS), suggesting that the metabolites arose from side branches of the main GA-biosynthetic pathway. Thus, both Na and na plants appear capable of ent-7..cap alpha..-hydroxylation.« less

  16. MEMS-based IR-sources

    NASA Astrophysics Data System (ADS)

    Weise, Sebastian; Steinbach, Bastian; Biermann, Steffen

    2016-03-01

    The series JSIR350 sources are MEMS based infrared emitters. These IR sources are characterized by a high radiation output. Thus, they are excellent for NDIR gas analysis and are ideally suited for using with our pyro-electric or thermopile detectors. The MEMS chips used in Micro-Hybrid's infrared emitters consist of nano-amorphous carbon (NAC). The MEMS chips are produced in the USA. All Micro-Hybrid Emitter are designed and specified to operate up to 850°C. The improvements we have made in the source's packaging enable us to provide IR sources with the best performance on the market. This new technology enables us to seal the housings of infrared radiation sources with soldered infrared filters or windows and thus cause the parts to be impenetrable to gases. Micro-Hybrid provide various ways of adapting our MEMS based infrared emitter JSIR350 to customer specifications, like specific burn-in parameters/characteristic, different industrial standard housings, producible with customized cap, reflector or pin-out.

  17. A novel "dual-potential" electrochemiluminescence aptasensor array using CdS quantum dots and luminol-gold nanoparticles as labels for simultaneous detection of malachite green and chloramphenicol.

    PubMed

    Feng, Xiaobin; Gan, Ning; Zhang, Huairong; Yan, Qing; Li, Tianhua; Cao, Yuting; Hu, Futao; Yu, Hongwei; Jiang, Qianli

    2015-12-15

    A novel type of "dual-potential" electrochemiluminescence (ECL) aptasensor array was fabricated on a homemade screen-printed carbon electrode (SPCE) for simultaneous detection of malachite green (MG) and chloramphenicol (CAP) in one single assay. The SPCE substrate consisted of a common Ag/AgCl reference electrode, carbon counter electrode and two carbon working electrodes (WE1 and WE2). In the system, CdS quantum dots (QDs) were modified on WE1 as cathode ECL emitters and luminol-gold nanoparticles (L-Au NPs) were modified on WE2 as anode ECL emitters. Then the MG aptamer complementary strand (MG cDNA) and CAP aptamer complementary strand (CAP cDNA) were attached on CdS QDs and L-Au NPs, respectively. The cDNA would hybridize with corresponding aptamer that was respectively tagged with cyanine dye (Cy5) (as quenchers of CdS QDs) and chlorogenic acid (CA) (as quenchers of l-Au NPs) using poly(ethylenimine) (PEI) as a bridging agent. PEI could lead to a large number of quenchers on the aptamer, which increased the quenching efficiency. Upon MG and CAP adding, the targets could induce strand release due to the highly affinity of analytes toward aptamers. Meanwhile, it could release the Cy5 and CA, which recovered cathode ECL of CdS QDs and anode ECL of L-Au NPs simultaneously. This "dual-potential" ECL strategy could be used to detect MG and CAP with the linear ranges of 0.1-100 nM and 0.2-150 nM, with detection limits of 0.03 nM and 0.07 nM (at 3sB), respectively. More importantly, this designed method was successfully applied to determine MG and CAP in real fish samples and held great potential in the food analysis. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Copernicus observations of Betelgeuse and Antares

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bernat, A.P.; Lambert, D.L.

    1975-01-01

    Copernicus observations of the M-supergiants, ..cap alpha.. Ori and ..cap alpha.. Sco, are presented. The Mg II H and K resonance lines are strongly in emission in both stars. The K line is highly asymmetric in both stars but the H line is symmetric. Upper limits for several other resonance lines are given for ..cap alpha.. Ori. The possibility is explored that the K line asymmetry is caused by overlying resonance lines of Mn I and Fe I formed in the cool circumstellar gas shells around these stars. Observations of the Mn I 4030--4033 A lines are used to showmore » that circumstellar shell absorption is too weak to explain the asymmetry. It is suggested that the absorption occurs in a cool turbulent region between the base of the circumstellar shell and the top of the chromosphere. (auth)« less

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walker, T.E.; Han, C.H.; Kollman, V.H.

    /sup 13/C NMR of isotopically enriched metabolites has been used to study the metabolism of Microbacterium ammoniaphilum, a bacterium which excretes large quantities of L-glutamic acid into the medium. Biosynthesis from 90% (1-/sup 13/C) glucose results in relatively high specificity of the label, with (2,4-/sup 13/C/sub 2/) glutamate as the major product. The predominant biosynthetic pathway for synthesis of glutamate from glucose was determined to be the Embden Meyerhof glycolytic pathway followed by P-enolpyruvate carboxylase and the first third of the Krebs cycle. Different metabolic pathways are associated with different correlations in the enrichment of the carbons, reflected in themore » spectrum as different /sup 13/C-/sup 13/C scalar multiplet intensities. Hence, intensity and /sup 13/C-/sup 13/C multiplet analysis allows quantitation of the pathways involved. Although blockage of the Krebs cycle at the ..cap alpha..-ketoglutarate dehydrogenase step is the basis for the accumulation of glutamate, significant Krebs cycle activity was found in glucose grown cells, and extensive Krebs cycle activity in cells metabolizing (1-/sup 13/C) acetate. In addition to the observation of the expected metabolites, the disaccharide ..cap alpha..,..cap alpha..-trehalose and ..cap alpha..,..beta..-glucosylamine were identified from the /sup 13/C NMR spectra.« less

  20. Switchable radioactive neutron source device

    DOEpatents

    Boyar, Robert E.; DeVolpi, Alexander; Stanford, George S.; Rhodes, Edgar A.

    1989-01-01

    This invention is a switchable neutron generating apparatus comprised of a pair of plates, the first plate having an alpha emitter section on it and the second plate having a target material portion on it which generates neutrons when its nuclei absorb an alpha particle. In operation, the alpha portion of the first plate is aligned with the neutron portion of the second plate to produce neutrons and brought out of alignment to cease production of neutrons.

  1. Fluorescence-Assisted Gamma Spectrometry for Surface Contamination Analysis

    NASA Astrophysics Data System (ADS)

    Ihantola, Sakari; Sand, Johan; Perajarvi, Kari; Toivonen, Juha; Toivonen, Harri

    2013-02-01

    A fluorescence-based alpha-gamma coincidence spectrometry approach has been developed for the analysis of alpha-emitting radionuclides. The thermalization of alpha particles in air produces UV light, which in turn can be detected over long distances. The simultaneous detection of UV and gamma photons allows detailed gamma analyses of a single spot of interest even in highly active surroundings. Alpha particles can also be detected indirectly from samples inside sealed plastic bags, which minimizes the risk of cross-contamination. The position-sensitive alpha-UV-gamma coincidence technique reveals the presence of alpha emitters and identifies the nuclides ten times faster than conventional gamma spectrometry.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, Brian W.; Frost, Sophia; Frayo, Shani

    Abstract Alpha emitting radionuclides exhibit a potential advantage for cancer treatments because they release large amounts of ionizing energy over a few cell diameters (50–80 μm) causing localized, irreparable double-strand DNA breaks that lead to cell death. Radioimmunotherapy (RIT) approaches using monoclonal antibodies labeled with alpha emitters may inactivate targeted cells with minimal radiation damage to surrounding tissues. For accurate dosimetry in alpha-RIT, tools are needed to visualize and quantify the radioactivity distribution and absorbed dose to targeted and non-targeted cells, especially for organs and tumors with heterogeneous radionuclide distributions. The aim of this study was to evaluate and characterizemore » a novel single-particle digital autoradiography imager, iQID (ionizing-radiation Quantum Imaging Detector), for use in alpha-RIT experiments. Methods: The iQID camera is a scintillator-based radiation detection technology that images and identifies charged-particle and gamma-ray/X-ray emissions spatially and temporally on an event-by-event basis. It employs recent advances in CCD/CMOS cameras and computing hardware for real-time imaging and activity quantification of tissue sections, approaching cellular resolutions. In this work, we evaluated this system’s characteristics for alpha particle imaging including measurements of spatial resolution and background count rates at various detector configurations and quantification of activity distributions. The technique was assessed for quantitative imaging of astatine-211 (211At) activity distributions in cryosections of murine and canine tissue samples. Results: The highest spatial resolution was measured at ~20 μm full width at half maximum (FWHM) and the alpha particle background was measured at a rate of (2.6 ± 0.5) × 10–4 cpm/cm2 (40 mm diameter detector area). Simultaneous imaging of multiple tissue sections was performed using a large-area iQID configuration (ø 11.5 cm). Estimation of the 211At activity distribution was demonstrated at mBq/μg levels. Conclusion: Single-particle digital autoradiography of alpha emitters has advantages over traditional autoradiographic techniques in terms of spatial resolution, sensitivity, and activity quantification capability. The system features and characterization results presented in this study show that iQID is a promising technology for microdosimetry, because it provides necessary information for interpreting alpha-RIT outcomes and for predicting the therapeutic efficacy of cell-targeted approaches using alpha emitters.« less

  3. An overview of targeted alpha therapy with 225Actinium and 213Bismuth.

    PubMed

    Morgenstern, Alfred; Apostolidis, Christos; Kratochwil, Clemens; Sathekge, Mike; Krolicki, Leszek; Bruchertseifer, Frank

    2018-05-01

    Recent reports of the remarkable therapeutic efficacy of 225Ac-labeled PSMA-617 for therapy of metastatic castration-resistant prostate cancer have underlined the clinical potential of targeted alpha therapy. This review describes methods for the production of 225Ac and its daughter nuclide 213Bi and summarizes the current clinical experience with both alpha emitters with particular focus on recent studies of targeted alpha therapy of bladder cancer, brain tumors, neuroendocrine tumors and prostate cancer. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  4. DEAD ZONE IN THE POLAR-CAP ACCELERATOR OF PULSARS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Alexander Y.; Beloborodov, Andrei M.

    We study plasma flows above pulsar polar caps using time-dependent simulations of plasma particles in the self-consistent electric field. The flow behavior is controlled by the dimensionless parameter {alpha} = j/c{rho}{sub GJ}, where j is the electric current density and {rho}{sub GJ} is the Goldreich-Julian charge density. The region of the polar cap where 0 < {alpha} < 1 is a {sup d}ead zone{sup -}in this zone, particle acceleration is inefficient and pair creation is not expected even for young, rapidly rotating pulsars. Pulsars with polar caps near the rotation axis are predicted to have a hollow-cone structure of radiomore » emission, as the dead zone occupies the central part of the polar cap. Our results apply to charge-separated flows of electrons (j < 0) or ions (j > 0). In the latter case, we consider the possibility of a mixed flow consisting of different ion species, and observe the development of two-stream instability. The dead zone at the polar cap is essential for the development of an outer gap near the null surface {rho}{sub GJ} = 0.« less

  5. Breakup processes in heavy-ion induced reactions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Udagawa, T.; Tamura, T.; Shimoda, T.

    1979-11-01

    Cross sections for breakup of /sup 20/Ne into /sup 16/O and ..cap alpha.. during scattering from /sup 40/Ca were calculated in terms of the distorted-wave Born approximation. The inclusive /sup 16/O cross section observed in the /sup 40/Ca(/sup 20/Ne,/sup 16/O) reaction was then found to be fitted very well by the sum of this breakup contribution and that of the ..cap alpha..-transfer reaction calculated in our previous work.

  6. Switchable radioactive neutron source device

    DOEpatents

    Stanford, G.S.; Rhodes, E.A.; Devolpi, A.; Boyar, R.E.

    1987-11-06

    This invention is a switchable neutron generating apparatus comprised of a pair of plates, the first plate having an alpha emitter section on it and the second plate having a target material portion on it which generates neutrons when its nuclei absorb an alpha particle. In operation, the alpha portion of the first plate is aligned with the neutron portion of the second plate to produce neutrons and brought out of alignment to cease production of neutrons. 3 figs.

  7. Dielectronic satellite spectra of hydrogen-like titanium (Ti XXII)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bitter, M.; von Goeler, S.; Cohen, S.

    High resolution spectra of the Ly ..cap alpha../sub 1/ and Ly ..cap alpha../sub 2/ lines of hydrogenlike titanium, TiXXII, and the associated dielectronic satellites which are due to transitions 1snl-2pnl with n greater than or equal to 2, have been observed from tokamak discharges with auxiliary ion cyclotron heating (ICRH) with central electron temperatures of 2 keV and central electron densities of 8 x 10/sup 13/ cm/sup -3/ on the Princeton Large Torus (PLT). The data have been used for a detailed comparison with theoretical predictions based on the Z - expansion method and Hartree - Fock calculations. The resultsmore » obtained with the Z - expansion method are in excellent agreement with the observed spectral data except for minor discrepancies between the theoretical and experimental wavelengths of 0.0003 A for the n = 2 satellites and of 0.0001 A for the separation of the Ly ..cap alpha../sub 1/ and Ly ..cap alpha../sub 2/ lines. Very good agreement with the experimental data is also obtained for the results from the Hartree - Fock calculations though somewhat larger discrepancies (approx. = 0.0009 A) exist between experimental and theoretical wavelengths which are systematically too small. The observed spectra are used for diagnosis of the central ion and electron temperatures of the PLT discharges and for a measurement of the dielectronic recombination rate coefficient of TiXXII.« less

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eremenko, D. O.; Fotina, O. V.; Platonov, S. Yu.

    The functional fitness of the alpha-emitter At-211 for radiotherapy of the thyroid gland cancer is evaluated. Radiation doses are calculated using the MIRD method and previously obtained pharmacokinetic data for At-211 in isotonic solution.

  9. Recent {alpha} decay half-lives and analytic expression predictions including superheavy nuclei

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Royer, G.; Zhang, H. F.

    New recent experimental {alpha} decay half-lives have been compared with the results obtained from previously proposed formulas depending only on the mass and charge numbers of the {alpha} emitter and the Q{sub {alpha}} value. For the heaviest nuclei they are also compared with calculations using the Density-Dependent M3Y (DDM3Y) effective interaction and the Viola-Seaborg-Sobiczewski (VSS) formulas. The correct agreement allows us to make predictions for the {alpha} decay half-lives of other still unknown superheavy nuclei from these analytic formulas using the extrapolated Q{sub {alpha}} of G. Audi, A. H. Wapstra, and C. Thibault [Nucl. Phys. A729, 337 (2003)].

  10. Test chamber for alpha spectrometry

    DOEpatents

    Larsen, Robert P.

    1977-01-01

    Alpha emitters for low-level radiochemical analysis by measurement of alpha spectra are positioned precisely with respect to the location of a surface-barrier detector by means of a chamber having a removable threaded planchet holder. A pedestal on the planchet holder holds a specimen in fixed engagement close to the detector. Insertion of the planchet holder establishes an O-ring seal that permits the chamber to be pumped to a desired vacuum. The detector is protected against accidental contact and resulting damage.

  11. Spatial resolution properties of digital autoradiography systems for pre-clinical alpha particle imaging (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Tanguay, Jesse; Benard, Francois; Celler, Anna; Ruth, Thomas; Schaffer, Paul

    2017-03-01

    Attaching alpha-emitting radionuclides to cancer-targeting agents increases the anti-tumor effects of targeted cancer therapies. The success of alpha therapy for treating bone metastases has increased interest in using targeted alpha therapy (TAT) to treat a broad spectrum of metastatic cancers. Estimating radiation doses to targeted tumors, including small (<250 μm) clusters of cancer cells, and to non-targeted tissues is critical in the pre-clinical development of TATs. However, accurate quantification of heterogeneous distributions of alpha-emitters in small metastases is not possible with existing pre-clinical in-vivo imaging systems. Ex-vivo digital autoradiography using a scintillator in combination with an image intensifier and a charged coupled device (CCD) has gained interest for pre-clinical ex-vivo alpha particle imaging. We present a simulation-based analysis of the fundamental spatial resolution limits of digital autoradiography systems. Spatial resolution was quantified in terms of the modulation transfer function (MTF) and Wagner's equivalent aperture. We modeled systems operating in either particle-counting (PC) or energy-integrating (EI) mode using a cascaded systems approach that accounts for: 1) the stopping power of alpha particles; 2) the distance alpha particles travel within the scintillator; 3) optical blur, and; 4) binning in detector elements. We applied our analysis to imaging of astatine-211 using an LYSO scintillator with thickness ranging from 10 μm to 20 μm. Our analysis demonstrates that when these systems are operated in particle-counting mode with a centroid-calculation algorithm, the effective apertures of 35 μm can be achieved, which suggests that digital autoradiography may enable quantifying the uptake of alpha emitters in tumors consisting of a few cancer cells. Future work will investigate the image noise and energy-resolution properties of digital autoradiography systems.

  12. Isolation of tungsten and tantalum isotopes without supports from. cap alpha. -particle-irradiated hafnium targets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gasita, S.M.; Iota, B.Z.; Malachkov, A.G.

    1985-11-01

    An extraction procedure has been developed for successive isolation of tungsten (/sup 178/W and /sup 181/W) and tantalum (/sup 179/Ta and /sup 182/Ta) isotopes without supports from ..cap alpha..particle-irradiated hafnium targets. The target, irradiated on a cyclotron, is dissolved in hydrofluoric acid. Tantalum isotopes are extracted with tributyl phosphate (TBP) from 1-5 M HF and are then reextracted with a 1:1 ammonia solution, and hydrofluoric acid is removed by heating. Tungsten isotopes are extracted with a chloroform solution or N-benzoyl-N-phenylhydroxylamine (BPHA) from 11-12 M H/sub 2/SO/sub 4/ or ..cap alpha..-benzoin oxime from 4.5-5.5 M H/sub 2/SO/sub 4/ and are thenmore » reextracted with a l:l ammonia solution. The yield of tungsten isotopes is not less than 95%, and the content of radioactive impurities of other isotopes is not more than 0.1%.« less

  13. Selective inhibition by chloramphenicol of pregnenolone-16. cap alpha. -carbonitrile-inducible rat liver cytochrome P-450 isozymes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Graves, P.E.; Kaminsky, L.S.; Halpert, J.

    Pregnenolone-16 ..cap alpha..-carbonitrile (PCN) has been shown to induce, in male rats, cytochrome P-450 isozymes responsible for the formation of R-10-hydroxywarfarin and R-dehydrowarfarin. Antibodies to the major PCN-inducible isozyme (PB/PCN-E) inhibit both activities in microsomal preparations. Recently the authors have shown that PCN treatment of female rats also induces the formation of both R-warfarin metabolites. However, in both sexes chloramphenicol (CAP) treatment selectively inhibits only the rate of formation of the R-dehydrowarfarin. A decrease in microsomal P-450 content occurs after in vivo administration of CAP to PCN-treated rats of both sexes. This is in contrast to the lack of effectmore » of CAP on P-450 levels in phenobarbital-treated rats. Covalent binding of /sup 14/C-CAP to microsomal protein in vitro was increased 3 to 4-fold following PCN treatment. Chromatographic evidences suggests the presence of at least two PCN-induced isozymes of similar molecular weights in both male and female rat liver microsomes. These data are consistent with the multiplicity of PCN-inducible P-450 in rat liver.« less

  14. Chromosomal aberrations and delays in cell progression induced by x-rays in Tradescantia clone 02 meristems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Geard, C.R.

    1983-01-01

    In root meristems of Tradescantia clone 02 (developed by Sparrow and his colleagues for mutation studies), X-rays interfere with the progression of cells through the cell cycle and induce chromosomal aberrations in a dose-dependent manner consistent with linear-quadratic kinetics. Sequential mitotic cell accumulations after irradiation indicate that sensitivity to aberration induction is probably greatest in cells from late S to early G2, with chromatid interchanges the most frequent aberration type and all aberrations consistent with initiation from the interaction between two lesions. The ratio of the coefficients in the linear (..cap alpha..) and the quadratic (..beta..) terms (..cap alpha../..beta..) ismore » equal to the dose average of specific energy produced by individual particles in the site where interaction takes place. The ratio ..cap alpha../..beta.. for chromosomal aberrations is similar to that previously found for X-ray-induced mutation in Tradescantia stamen hairs, supporting the proposal that radiation-induced mutational events are due to chromosomal aberrations with interaction distances of about 1..mu..m. Abrahamson and co-workers have noted that both ..cap alpha../..beta.. ratios appear to be related to nuclear target size and are similar for chromosomal and mutational endpoints in the same organism. These findings support this concept; however, it is apparent that any situation which diminishes yield at high doses (e.g., mitotic delay) will probably affect the ..beta.. component. 23 references, 5 figures, 2 tables.« less

  15. Chromosomal aberrations and delays in cell progression induced by x-rays in Tradescantia clone 02 meristems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Geard, C.R.

    1983-01-01

    In root meristems of Tradescantia clone 02 (developed by Sparrow and his colleagues for mutation studies), X-rays interfere with the progression of cells through the cell cycle and induce chromosomal aberrations in a dose-dependent manner consistent with linear-quadratic kinetics. Sequential mitotic cell accumulations after irradiation indicate that sensitivity to aberrration induction is probably greatest in cells from late S to early G2, with chromatid interchanges the most frequent aberration type and all aberrations consistent with intiation from the interaction between two lesions. The ratio of the coefficients in the linear (..cap alpha..) and the quadratic (..beta..) terms (..cap alpha../..beta..) ismore » equal to the dose average of specific energy produced by individual particles in the site where interaction takes place. The ratio ..cap alpha../..beta.. for chromosomal aberrations is similar to that previously found for X-ray-induced mutation in Tradescantia stamen hairs, supporting the proposal that radiation-induced mutational events are due to chromosomal aberrations with interaction distances of about 1 ..mu..m. Abrahmson and co-workers have noted that both ..cap alpha../..beta.. ratios appear to be related to nuclear target size and are similar for chromosomal and mutational endpoints in the same organism. These findings support this concept; however, it is apparent that any situation which diminishes yield at high doses (e.g., mitotic delay) will primarily affect the ..beta.. component, resulting in low assessments of interaction site diameters.« less

  16. Exact near-onset analysis of the spin-density-wave instability in ferromagnetic superconductors: The linearly polarized state

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hu, C.

    1984-09-01

    Using an approach similar to Abvikosov's theory of the vortex state near H/sub c/2, we have performed an exact, near-onset analysis of a spin-density-wave instability leading to the ''linearly polarized state'' of Greenside et al. in ferromagnetic superconductors. The approach is based on a generalized Ginzburg-Landau theory for such materials, as formulated by Blount and Varma. Two models have been considered. In the (..cap alpha..,..beta..) model, where the bulk magnetic energy is taken to be (1/2)..cap alpha../sub m/M/sup 2/+(1/4)..beta../sub m/M/sup 4/, we find the transition to be second order, and obtain explicit formulas for various physical quantities to leading ordermore » in the deviation from onset. We have also rigorously analyzed the most favored spatial structure just below onset, among all possibilities allowed by the instability, and have concluded that a plane-wave-like structure is favored in a physical limit considered. In the (..cap alpha..,..gamma..) model, where the bulk magnetic energy is taken to be (1/2)..cap alpha../sub m/M/sup 2/+(1/6)..gamma../sub m/M/sup 6/ as is supported by recent experiments for ErRh/sub 4/B/sub 4/, we find the transition to be first order. This approach is then confined to an unphysical branch, which does not permit us to calculate various physical quantities on the physical branch.« less

  17. Drosophila Casein Kinase I Alpha Regulates Homolog Pairing and Genome Organization by Modulating Condensin II Subunit Cap-H2 Levels

    PubMed Central

    Nguyen, Huy Q.; Nye, Jonathan; Buster, Daniel W.; Klebba, Joseph E.; Rogers, Gregory C.; Bosco, Giovanni

    2015-01-01

    The spatial organization of chromosomes within interphase nuclei is important for gene expression and epigenetic inheritance. Although the extent of physical interaction between chromosomes and their degree of compaction varies during development and between different cell-types, it is unclear how regulation of chromosome interactions and compaction relate to spatial organization of genomes. Drosophila is an excellent model system for studying chromosomal interactions including homolog pairing. Recent work has shown that condensin II governs both interphase chromosome compaction and homolog pairing and condensin II activity is controlled by the turnover of its regulatory subunit Cap-H2. Specifically, Cap-H2 is a target of the SCFSlimb E3 ubiquitin-ligase which down-regulates Cap-H2 in order to maintain homologous chromosome pairing, chromosome length and proper nuclear organization. Here, we identify Casein Kinase I alpha (CK1α) as an additional negative-regulator of Cap-H2. CK1α-depletion stabilizes Cap-H2 protein and results in an accumulation of Cap-H2 on chromosomes. Similar to Slimb mutation, CK1α depletion in cultured cells, larval salivary gland, and nurse cells results in several condensin II-dependent phenotypes including dispersal of centromeres, interphase chromosome compaction, and chromosome unpairing. Moreover, CK1α loss-of-function mutations dominantly suppress condensin II mutant phenotypes in vivo. Thus, CK1α facilitates Cap-H2 destruction and modulates nuclear organization by attenuating chromatin localized Cap-H2 protein. PMID:25723539

  18. Spectral reflectance properties of electroplated and converted zinc for use as a solar selective coating

    NASA Technical Reports Server (NTRS)

    Mcdonald, G. E.; Curtis, H. B.; Gianelos, L.

    1975-01-01

    The spectral reflectance properties of electroplated and chemically converted zinc were measured for both chromate and chloride conversion coatings. The reflectance properties were measured for various times of conversion and for conversion at various chromate concentrations. The values of absorptance, alpha, integrated over the solar spectrum, and of infrared emittance, epsilon, integrated over black body radiation at 250 F were then calculated from the measured reflectance values. The interdependent variations of alpha and epsilon were plotted. The results indicate that the optimum combination of the highest absorptance in the solar spectrum and the lowest emittance in the infrared of the converted electroplated zinc is produced by chromate conversion at 1/2 concentration of the standard NEOSTAR chromate black solution for 0.50 minute or by chloride conversion for 0.50 minute.

  19. Development and Testing of a 212Pb/212Bi Peptide for Targeting Metastatic Melanoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fisher, Darrell R.

    2012-10-25

    The purpose of this project is to develop a new radiolabeled peptide for imaging and treating metastatic melanoma. The immunoconjugate consists of a receptor-specific peptide that targets melanoma cells. The beta-emitter lead-212 (half-life = 10.4 hours) is linked by coordination chemistry to the peptide. After injection, the peptide targets melanoma receptors on the surfaces of melanoma cells. Lead-212 decays to the alpha-emitter bismuth-212 (half-life = 60 minutes). Alpha-particles that hit melanoma cell nuclei are likely to kill the melanoma cell. For cancer cell imaging, the lead-212 is replaced by lead-203 (half-life = 52 hours). Lead-203 emits 279 keV photons (80.1%more » abundance) that can be imaged and measured for biodistribution analysis, cancer imaging, and quantitative dosimetry.« less

  20. Role of constant value of surface diffuseness in alpha decay half-lives of superheavy nuclei

    NASA Astrophysics Data System (ADS)

    Dehghani, V.; Alavi, S. A.; Benam, Kh.

    2018-05-01

    By using WKB method and considering deformed Woods-Saxon nuclear potential, deformed Coulomb potential, and centrifugal potential, the alpha decay half-lives of 68 superheavy alpha emitters have been calculated. The effect of the constant value of surface diffuseness parameter in the range of 0.1 ≤ a ≤ 0.9 (fm) on the potential barrier, tunneling probability, assault frequency, and alpha decay half-lives has been investigated. Significant differences were observed for alpha decay half-lives and decay quantities in this range of surface diffuseness. Good agreement between calculated half-lives with fitted surface diffuseness parameter a = 0.54 (fm) and experiment was observed.

  1. Antisymmetrization effects and the form factor of the real part of the. cap alpha. -nucleus potential

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Majka, Z.; Budzanowski, A.; Grotowski, K.

    1978-07-01

    Antisymmetrization effects in the ..cap alpha..-nucleus interaction are investigated on the basis of a microscopic model in an one nucleon exchange approximation. It influences the form factor, increasing the halfway radius and decreasing the diffuseness as compared with the direct term of the potential only. Antisymmetrization preserves the shape of the potential which can be parametrized by a Woods-Saxon squared form. The phenomenological potential with the energy independent form factor of the above shape fits experimental data in a wide energy region.

  2. Cross sections and differential spectra for reactions of 2-20 MeV neutrons of /sup 27/Al

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blann, M.; Komoto, T.T.

    1988-01-01

    This report summarizes product yields, secondary n,p and ..cap alpha.. spectra, and ..gamma..-ray spectra calculated for incident neutrons of 2-20 MeV on /sup 27/Al targets. Results are all from the code ALICE, using the version ALISO which does weighting of results for targets which are a mix of isotopes. Where natural isotopic targets are involved, yields and n,p,..cap alpha.. spectra will be reported weighted over isotopic yields. Gamma-ray spectra, however, will be reported for the most abundant isotope.

  3. Evaluation of the use of reverse osmosis to eliminate natural radionuclides from water samples.

    PubMed

    Nieto, Antonio; Palomo, Marta; Ruana, Josep; Peñalver, Alejandra; Aguilar, Carme; Borrull, Francesc

    2013-12-01

    The objective of drinking water treatment plants (DWTP) is to supply the population with tap water that is in optimal condition and in compliance with water quality regulations. In the DWTP of L'Ampolla (Tarragona, Spain), slightly high values of gross alpha activity and the amount of salts in the raw water have been observed. Conventional treatment has reduced these levels only minimally. This study tested a tertiary treatment based on reverse osmosis is tested in an industrial pilot plant (240 m3/day) The efficiency of this pilot plant to reduce the gross alpha and beta activities and the activity of some individual radioisotopes (U(238), U(234), U(235) and Ra(226)) was tested. Results showed that the elimination of alpha emitters was greater than 90%, whereas the elimination of beta emitters was about 35%. Overall, the data provided evidence that the pilot plant is effective for removing different radionuclides that can be present in the incoming water treated. Therefore, tertiary treatment based on reverse osmosis has a positive effect in water quality.

  4. Adaptation and impairment of DNA repair function in pollen of Betula verrucosa and seeds of Oenothera biennis from differently radionuclide-contaminated sites of Chernobyl.

    PubMed

    Boubriak, I I; Grodzinsky, D M; Polischuk, V P; Naumenko, V D; Gushcha, N P; Micheev, A N; McCready, S J; Osborne, D J

    2008-01-01

    The plants that have remained in the contaminated areas around Chernobyl since 1986 encapsulate the effects of radiation. Such plants are chronically exposed to radionuclides that they have accumulated internally as well as to alpha-, beta- and gamma-emitting radionuclides from external sources and from the soil. This radiation leads to genetic damage that can be countered by DNA repair systems. The objective of this study is to follow DNA repair and adaptation in haploid cells (birch pollen) and diploid cells (seed embryos of the evening primrose) from plants that have been growing in situ in different radionuclide fall-out sites in monitored regions surrounding the Chernobyl explosion of 1986. Radionuclide levels in soil were detected using gamma-spectroscopy and radiochemistry. DNA repair assays included measurement of unscheduled DNA synthesis, electrophoretic determination of single-strand DNA breaks and image analysis of rDNA repeats after repair intervals. Nucleosome levels were established using an ELISA kit. Birch pollen collected in 1987 failed to perform unscheduled DNA synthesis, but pollen at gamma/beta-emitter sites has now recovered this ability. At a site with high levels of combined alpha- and gamma/beta-emitters, pollen still exhibits hidden damage, as shown by reduced unscheduled DNA synthesis and failure to repair lesions in rDNA repeats properly. Evening primrose seed embryos generated on plants at the same gamma/beta-emitter sites now show an improved DNA repair capacity and ability to germinate under abiotic stresses (salinity and accelerated ageing). Again those from combined alpha- and gamma/beta-contaminated site do not show this improvement. Chronic irradiation at gamma/beta-emitter sites has provided opportunities for plant cells (both pollen and embryo cells) to adapt to ionizing irradiation and other environmental stresses. This may be explained by facilitation of DNA repair function.

  5. Final Report for DUSEL R&D: BetaCage: A Screener of Ultra-Low-Level Radioactive Surface Contamination

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Golwala, Sunil R.

    2013-12-20

    The eventual full-size, radiopure BetaCage will be a low-background, atmospheric-pressure neon drift chamber with unprecedented sensitivity to emitters of low-energy electrons and alpha particles. We expect that the prototype BetaCage already developed will be an excellent screener of alpha particles. Both the prototype and final BetaCage will provide new infrastructure for rare-event science.

  6. The treatment of solid tumors by alpha emitters released from 224Ra-loaded sources—internal dosimetry analysis

    NASA Astrophysics Data System (ADS)

    Arazi, L.; Cooks, T.; Schmidt, M.; Keisari, Y.; Kelson, I.

    2010-02-01

    Diffusing alpha-emitters radiation therapy (DART) is a proposed new form of brachytherapy, allowing the treatment of solid tumors by alpha particles. DART utilizes implantable sources carrying small activities of radium-224, which continually release into the tumor radon-220, polonium-216 and lead-212 atoms, while radium-224 itself remains fixed to the source. The released atoms disperse inside the tumor by diffusive and convective processes, creating, through their alpha emissions, a high-dose region measuring several mm in diameter about each source. The efficacy of DART has been demonstrated in preclinical studies on mice-borne squamous cell carcinoma and lung tumors and the method is now being developed toward clinical trials. This work studies DART safety with respect to the dose delivered to distant organs as a result of lead-212 leakage from the tumor through the blood, relying on a biokinetic calculation coupled to internal dose assessments. It is found that the dose-limiting organs are the kidneys and red bone marrow. Assuming a typical source spacing of ~5 mm and a typical radium-224 activity density of 0.4-0.8 MBq g-1 of tumor tissue, it is predicted that tumors weighing up to several hundred grams may be treated without reaching the tolerance dose in any organ.

  7. GAS MOTION STUDY OF Ly{alpha} EMITTERS AT z {approx} 2 USING FUV AND OPTICAL SPECTRAL LINES {sup ,}

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hashimoto, Takuya; Shimasaku, Kazuhiro; Nakajima, Kimihiko

    2013-03-01

    We present the results of Magellan/MMIRS and Keck/NIRSPEC spectroscopy for five Ly{alpha} emitters (LAEs) at z {approx_equal} 2.2 for which high-resolution FUV spectra from Magellan/MagE are available. We detect nebular emission lines including H{alpha} on the individual basis and low-ionization interstellar (LIS) absorption lines in a stacked FUV spectrum, and measure average offset velocities of the Ly{alpha} line, {Delta}v {sub Ly{alpha}}, and LIS absorption lines, {Delta}v {sub abs}, with respect to the systemic velocity defined by the nebular lines. For a sample of eight z {approx} 2-3 LAEs without active galactic nucleus from our study and the literature, we obtainmore » {Delta}v {sub Ly{alpha}} = 175 {+-} 35 km s{sup -1}, which is significantly smaller than that of Lyman-break Galaxies (LBGs), {Delta}v {sub Ly{alpha}} {approx_equal} 400 km s{sup -1}. The stacked FUV spectrum gives {Delta}v {sub abs} = -179 {+-} 73 km s{sup -1}, comparable to that of LBGs. These positive {Delta}v {sub Ly{alpha}} and negative {Delta}v {sub abs} suggest that LAEs also have outflows. In contrast to LBGs, however, the LAEs' {Delta}v {sub Ly{alpha}} is as small as |{Delta}v {sub abs}|, suggesting low neutral hydrogen column densities. Such a low column density with a small number of resonant scattering may cause the observed strong Ly{alpha} emission of LAEs. We find an anti-correlation between Ly{alpha} equivalent width (EW) and {Delta}v {sub Ly{alpha}} in a compilation of LAE and LBG samples. Although its physical origin is not clear, this anti-correlation result appears to challenge the hypothesis that a strong outflow, by means of a reduced number of resonant scattering, produces a large EW. If LAEs at z > 6 have similarly small {Delta}v {sub Ly{alpha}} values, constraints on the reionization history derived from the Ly{alpha} transmissivity may need to be revised.« less

  8. A Detector Scenario for a Muon Cooling Demonstration Experiment

    NASA Astrophysics Data System (ADS)

    McDonald, Kirk T.; Lu, Changguo; Prebys, Eric J.

    1998-04-01

    As a verification of the concept of ionization cooling of a muon beam, the Muon Collider Collaboration is planning an experiment to cool the 6-dimensional normalized emittance by a factor of two. We have designed a detector system to measure the 6-dimensional emittance before and after the cooling apparatus. To avoid the cost associated with preparation of a muon beam bunched at 800 MHz, the nominal frequency of the RF in the muon cooler, we propose to use an unbunched muon beam. Muons will be measured in the detector individually, and a subset chosen corresponding to an ideal input bunch. The muons are remeasured after the cooling apparatus and the output bunch emittance calculated to show the expected reduction in phase-space volume. The technique of tracing individual muons will reproduce all effects encountered by a bunch except for space-charge.

  9. Separation of anionic oligosaccharides by high-performance liquid chromatography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Green, E.D.; Baenziger, J.U.

    1986-10-01

    The authors have developed methods for rapid fractionation of anionic oligosaccharides containing sulfate and/or sialic acid moieties by high-performance liquid chromatography (HPLC). Ion-exchange HPLC on amine-bearing columns (Micropak AX-10 and AX-5) at pH 4.0 is utilized to separate anionic oligosaccharides bearing zero, one, two, three, or four charges, independent of the identity of the anionic moieties (sulfate and/or sialic acid). Ion-exchange HPLC at pH 1.7 allows separation of neutral, mono-, di-, and tetrasialylated, monosulfated, and disulfated oligosaccharides. Oligosaccharides containing three sialic acid residues and those bearing one each of sulfate and sialic acid, however, coelute at pH 1.7. Since themore » latter two oligosaccharide species separate at pH 4.0, analysis at pH 4.0 followed by analysis at pH 1.7 can be utilized to completely fractionate complex mixtures of sulfated and sialylated oligosaccharides. Ion-suppression amine adsorption HPLC has previously been shown to separate anionic oligosaccharides on the basis of net carbohydrate content (size). In this study they demonstrate the utility of ion-suppression amine adsorption HPLC for resolving sialylated oligosaccharide isomers which differ only in the linkages of sialic acid residues (..cap alpha..2,3 vs ..cap alpha..2,6) and/or location of ..cap alpha..2,3- and ..cap alpha..2,6-linked sialic acid moieties on the peripheral branches of oligosaccharides. These two methods can be used in tandem to separate oligosaccharides, both analytically and preparatively, based on their number, types, and linkages of anionic moieties.« less

  10. Design and Development of Emittance Measurement Device by Using the Pepper-pot Technique

    NASA Astrophysics Data System (ADS)

    Pakluea, S.; Rimjaem, S.

    2017-09-01

    Transverse emittance of a charged particle beam is one of the most important properties that reveals the quality of the beam. It is related to charge density, transvers size and angular displacement of the beam in transverse phase space. There are several techniques to measure the transverse emittance value. One of practical methods is the pepper-pot technique, which can measure both horizontal and vertical emittance value in a single measurement. This research concentrates on development of a pepper-pot device to measure the transverse emittance of electron beam produced from an accelerator injector system, which consists of a thermionic cathode RF electron gun and an alpha magnet, at the Plasma and Beam Physics Research Facility, Chiang Mai University. Simulation of beam dynamics was conducted with programs PARMELA, ELEGANT and self-developed codes using C and MATLAB. The geometry, dimensions and location of the pepper-pot as well as its corresponding screen station position were included in the simulation. The result from this study will be used to design and develop a practical pepper-pot experimental station.

  11. Tubulin chaperone E binds microtubules and proteasomes and protects against misfolded protein stress.

    PubMed

    Voloshin, Olga; Gocheva, Yana; Gutnick, Marina; Movshovich, Natalia; Bakhrat, Anya; Baranes-Bachar, Keren; Bar-Zvi, Dudy; Parvari, Ruti; Gheber, Larisa; Raveh, Dina

    2010-06-01

    Mutation of tubulin chaperone E (TBCE) underlies hypoparathyroidism, retardation, and dysmorphism (HRD) syndrome with defective microtubule (MT) cytoskeleton. TBCE/yeast Pac2 comprises CAP-Gly, LRR (leucine-rich region), and UbL (ubiquitin-like) domains. TBCE folds alpha-tubulin and promotes alpha/beta dimerization. We show that Pac2 functions in MT dynamics: the CAP-Gly domain binds alpha-tubulin and MTs, and functions in suppression of benomyl sensitivity of pac2Delta mutants. Pac2 binds proteasomes: the LRR binds Rpn1, and the UbL binds Rpn10; the latter interaction mediates Pac2 turnover. The UbL also binds the Skp1-Cdc53-F-box (SCF) ubiquitin ligase complex; these competing interactions for the UbL may impact on MT dynamics. pac2Delta mutants are sensitive to misfolded protein stress. This is suppressed by ectopic PAC2 with both the CAP-Gly and UbL domains being essential. We propose a novel role for Pac2 in the misfolded protein stress response based on its ability to interact with both the MT cytoskeleton and the proteasomes.

  12. [Low level alpha activity measurements with pulse shape discrimination--application to the determination of alpha-nuclides in environmental samples].

    PubMed

    Satoh, K; Noguchi, M; Higuchi, H; Kitamura, K

    1984-12-01

    Liquid scintillation counting of alpha rays with pulse shape discrimination was applied to the analysis of 226Ra and 239+240Pu in environmental samples and of alpha-emitters in/on a filter paper. The instrument used in this study was either a specially designed detector or a commercial liquid scintillation counter with an automatic sample changer, both of which were connected to the pulse shape discrimination circuit. The background counting rate in alpha energy region of 5-7 MeV was 0.01 or 0.04 cpm/MeV, respectively. The figure of merit indicating the resolving power for alpha- and beta-particles in time spectrum was found to be 5.7 for the commercial liquid scintillation counter.

  13. Local Control of Lung Derived Tumors by Diffusing Alpha-Emitting Atoms Released From Intratumoral Wires Loaded With Radium-224

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cooks, Tomer; Schmidt, Michael; Bittan, Hadas

    2009-07-01

    Purpose: Diffusing alpha-emitters radiation therapy (DART) is a new form of brachytherapy enabling the treatment of solid tumors with alpha radiation. The present study examines the antitumoral effects resulting from the release of alpha emitting radioisotopes into solid lung carcinoma (LL2, A427, and NCI-H520). Methods and Materials: An in vitro setup tested the dose-dependent killing of tumor cells exposed to alpha particles. In in vivo studies, radioactive wires (0.3 mm diameter, 5 mm long) with {sup 224}Ra activities in the range of 21-38 kBq were inserted into LL/2 tumors in C57BL/6 mice and into human-derived A427 or NCI-H520 tumors inmore » athymic mice. The efficacy of the short-lived daughters of {sup 224}Ra to produce tumor growth retardation and prolong life was assessed, and the spread of radioisotopes inside tumors was measured using autoradiography. Results: The insertion of a single DART wire into the center of 6- to 7-mm tumors had a pronounced retardation effect on tumor growth, leading to a significant inhibition of 49% (LL2) and 93% (A427) in tumor development and prolongations of 48% (LL2) in life expectancy. In the human model, more than 80% of the treated tumors disappeared or shrunk. Autoradiographic analysis of the treated sectioned tissue revealed the intratumoral distribution of the radioisotopes, and histological analysis showed corresponding areas of necrosis. In vitro experiments demonstrated a dose-dependent killing of tumors cells exposed to alpha particles. Conclusions: Short-lived diffusing alpha-emitters produced tumor growth retardation and increased survival in mice bearing lung tumor implants. These results justify further investigations with improved dose distributions.« less

  14. Treatment of solid tumors by interstitial release of recoiling short-lived alpha emitters

    NASA Astrophysics Data System (ADS)

    Arazi, L.; Cooks, T.; Schmidt, M.; Keisari, Y.; Kelson, I.

    2007-08-01

    A new method utilizing alpha particles to treat solid tumors is presented. Tumors are treated with interstitial radioactive sources which continually release short-lived alpha emitting atoms from their surface. The atoms disperse inside the tumor, delivering a high dose through their alpha decays. We implement this scheme using thin wire sources impregnated with 224Ra, which release by recoil 220Rn, 216Po and 212Pb atoms. This work aims to demonstrate the feasibility of our method by measuring the activity patterns of the released radionuclides in experimental tumors. Sources carrying 224Ra activities in the range 10-130 kBq were used in experiments on murine squamous cell carcinoma tumors. These included gamma spectroscopy of the dissected tumors and major organs, Fuji-plate autoradiography of histological tumor sections and tissue damage detection by Hematoxylin-Eosin staining. The measurements focused on 212Pb and 212Bi. The 220Rn/216Po distribution was treated theoretically using a simple diffusion model. A simplified scheme was used to convert measured 212Pb activities to absorbed dose estimates. Both physical and histological measurements confirmed the formation of a 5-7 mm diameter necrotic region receiving a therapeutic alpha-particle dose around the source. The necrotic regions shape closely corresponded to the measured activity patterns. 212Pb was found to leave the tumor through the blood at a rate which decreased with tumor mass. Our results suggest that the proposed method, termed DART (diffusing alpha-emitters radiation therapy), may potentially be useful for the treatment of human patients.

  15. Calculated half-lives and kinetic energies for spontaneous emission of heavy ions from nuclei

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poenaru, D.N.; Greiner, W.; Depta, K.

    The most probable decays by spontaneous emission of heavy ions are listed for nuclides with Z = 47--106 and total half-lives>1 ..mu..sec. Partial half-lives, branching ratios relative to ..cap alpha.. decay, kinetic energies, and Q values are estimated by using the analytical superasymmetric fission model, a semiempirical formula for those ..cap alpha..-decay lifetimes which have not been measured, and the new Wapstra--Audi mass tables. Numerous ''stable'' nuclides with Z>40 are found to be metastable with respect to the new decay modes. The current experimental status is briefly reviewed.

  16. Algal succession and chronosequences on abandoned mine spoils

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shubert, L.E.; Starks, T.L.

    1978-06-01

    Soils were collected from spoil material aged 0 to 45 years. The soils were analyzed for the presence of algal species, chlorophyll ..cap alpha.., major cations, anions and trace elements. There was a gradual increase in the number of algal species and chlorophyll ..cap alpha.. from 1 year old spoils to adjacent unmined natural sites. A total of 41 algal species were identified from all sites. Several species were only found at the unmined sites and they may represent a stable algal community. Results of a statistical analysis on the litho- and chronosequence of the soils will be discussed.

  17. Periodic Table of Elements: Los Alamos National Laboratory

    Science.gov Websites

    during the formation of the Earth (4.5 billion years old) has long since decayed away by now. However ) neutrons. Neptunium-237 is irradiated with neutrons to create 238Pu, an alpha emitter for radioisotope

  18. KECK SPECTROSCOPY OF FAINT 3 < z < 8 LYMAN BREAK GALAXIES: EVIDENCE FOR A DECLINING FRACTION OF EMISSION LINE SOURCES IN THE REDSHIFT RANGE 6 < z < 8

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schenker, Matthew A.; Ellis, Richard S.; Robertson, Brant E.

    2012-01-10

    Using deep Keck spectroscopy of Lyman break galaxies selected from infrared imaging data taken with the Wide Field Camera 3 on board the Hubble Space Telescope, we present new evidence for a reversal in the redshift-dependent fraction of star-forming galaxies with detectable Lyman alpha (Ly{alpha}) emission in the redshift range 6.3 < z < 8.8. Our earlier surveys with the DEIMOS spectrograph demonstrated a significant increase with redshift in the fraction of line emitting galaxies over the interval 4 < z < 6, particularly for intrinsically faint systems which dominate the luminosity density. Using the longer wavelength sensitivities of Lowmore » Resolution Imaging Spectrometer and NIRSPEC, we have targeted 19 Lyman break galaxies selected using recent WFC3/IR data whose photometric redshifts are in the range 6.3 < z < 8.8 and which span a wide range of intrinsic luminosities. Our spectroscopic exposures typically reach a 5{sigma} sensitivity of <50 A for the rest-frame equivalent width (EW) of Ly{alpha} emission. Despite the high fraction of emitters seen only a few hundred million years later, we find only two convincing and one possible line emitter in our more distant sample. Combining with published data on a further seven sources obtained using FORS2 on the ESO Very Large Telescope, and assuming continuity in the trends found at lower redshift, we discuss the significance of this apparent reversal in the redshift-dependent Ly{alpha} fraction in the context of our range in continuum luminosity. Assuming all the targeted sources are at their photometric redshift and our assumptions about the Ly{alpha} EW distribution are correct, we would expect to find so few emitters in less than 1% of the realizations drawn from our lower redshift samples. Our new results provide further support for the suggestion that, at the redshifts now being probed spectroscopically, we are entering the era where the intergalactic medium is partially neutral. With the arrival of more sensitive multi-slit infrared spectrographs, the prospects for improving the statistical validity of this result are promising.« less

  19. Biosynthesis of ketomycin. (II) biomimetic model for beta-lactamase catalysis: host-guest interactions in cyclodextrin-penicillin inclusion complex

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mak, H.W.

    The antibiotic ketomycin is formed from shikimic acid via chorismic acid and prephenic acid. Phenylalanine and 2',5'-dihydrophenylalanine derived from shikimic acid are not intermediates in the biosynthesis. Degradation of ketomycin derived from (1,6-/sup 14/C)shikimic acid showed that prephenic acid is converted into ketomycin with stereospecific discrimination between the two enantiotopic edges of the ring, the pro-S-R edge giving rise to the C-2', C-3' side of the cyclohexane ring of ketomycin. The resistance of pathogenic bacteria to the action of ..beta..-lactam antibiotics is mainly ascribed to their ability to produce ..beta..-lactamase to cleave the ..beta..-lactam ring. It is essential to understandmore » the molecular nature of ..beta..-lactamase-penicillin recognition for designing and formulating more effective ..beta..-lactam antibiotics. A biomimetic study of ..beta..-lactamase is therefore initiated. To meet the requirements of hydrophobic and serine protease characteristics of ..beta..-lactamase, ..cap alpha..-cyclodextrin is chosen as a biomimetic model for ..beta..-lactamase. The structural specificity and the chemical dynamics of ..cap alpha..-cyclodextrin-phenoxymethyl penicillin inclusion complex in solid state and in solution have been determined by IR and NMR spectroscopy. The spectral results strongly indicate that the phenyl portion of the phenoxymethyl penicillin forms a stable inclusion complex with the hydrophobic cavity of ..cap alpha..-cyclodextrin in solution as well as in the solid state. Kinetic studies followed by /sup 1/HNMR and HPLC analyses under alkaline condition have shown that the ..cap alpha..-cyclodextrin mimics the catalytic function of serine of ..beta..-lactamase in the stereospecific hydrolysis of the ..beta..-lactam ring of phenoxymethyl penicillin.« less

  20. Transuranic isotopes and 90Sr in attic dust in the vicinity of two nuclear establishments in northern Germany.

    PubMed

    Schmitz-Feuerhake, I; Mietelski, J W; Gaca, P

    2003-05-01

    Attic dust was chosen as the test medium in order to search for traces of man-made bone seeking alpha and beta emitters. The samples were taken from 5 houses in the community of Elbmarsch situated at the river Elbe, adjacent to the Krümmel nuclear power plant and the nuclear research center of Geesthacht. Five houses in other regions of northern Germany were taken as a control. 238Pu, (239,240)Pu, 241Am, and 244Cm were measured by alpha spectrometry after chemical separation. Additionally, 241Pu was measured by liquid scintillation spectrometry, and the fission product 90Sr was measured in a separate investigation. All nuclides except 244Cm showed activities above the detection limit in the Elbmarsch samples and an elevated mean concentration compared to the control. It can be concluded from the activity ratio 241Am/(239,240)Pu that the Elbmarsch contamination cannot be accounted for by the background levels of transuranic nuclides resulting from weapons fallout. The derived release of alpha emitters is assumed to have contributed to the induction of a leukemia cluster in children, which was observed in Elbmarsch between 1990 and 1996.

  1. DEEP LBT/LUCI SPECTROSCOPY OF AN Ly{alpha} EMITTER CANDIDATE AT z {approx_equal} 7.7

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jiang Linhua; Bian Fuyan; Fan Xiaohui

    2013-07-01

    We present deep spectroscopic observations of an Ly{alpha} emitter (LAE) candidate at z {approx_equal} 7.7 using the infrared spectrograph LUCI on the 2 Multiplication-Sign 8.4 m Large Binocular Telescope (LBT). The candidate is the brightest among the four z {approx_equal} 7.7 LAE candidates found in a narrowband imaging survey by Krug et al. Our spectroscopic data include a total of 7.5 hr of integration with LBT/LUCI and are deep enough to significantly (3.2{sigma}-4.9{sigma}) detect the Ly{alpha} emission line of this candidate based on its Ly{alpha} flux 1.2 Multiplication-Sign 10{sup -17} erg s{sup -1} cm{sup -2} estimated from the narrowband photometry.more » However, we do not find any convincing signal at the expected position of its Ly{alpha} emission line, suggesting that this source is not an LAE at z {approx_equal} 7.7. The non-detection in this work, together with the previous studies of z {approx_equal} 7.7 LAEs, puts a strong constraint on the bright-end Ly{alpha} luminosity function (LF) at z {approx_equal} 7.7. We find a rapid evolution of the Ly{alpha} LF from z {approx_equal} 6.5 to 7.7: the upper limit of the z {approx_equal} 7.7 LF is more than five times lower than the z {approx_equal} 6.5 LF at the bright end (f{>=} 1.0 Multiplication-Sign 10{sup -17} erg s{sup -1} cm{sup -2} or L{>=} 6.9 Multiplication-Sign 10{sup 42} erg s{sup -1}). This is likely caused by an increasing neutral fraction in the intergalactic medium that substantially attenuates Ly{alpha} emission at z {approx_equal} 7.7.« less

  2. [Cytokine changes in community-acquired pneumonia in elderly and intervention of traditional Chinese medicine].

    PubMed

    Ye, Shanghe; Gong, Guolang; Zheng, Haiwen; Hu, Guohua; Xia, Tao

    2010-06-01

    To make a study of the cytokine changes in community-acquired pneumonia (CAP) in the elderly and the intervention of traditional Chinese medicine that can clear away the lung-heat and dissipate blood stasis (Qingfeihuayu soup). The 82 cases with CAP in the elderly were divided at random into two treatment group and control group. Based on heteropathy, the treatment group was given Qingfeihuayu soup two times a day. The control group was given Rocephin 2 g once daily for 7 days. The clinical effect and the changes in TNF-alpha, IL-6 and IL-10 were observed before and after the treatment. A healthy group was also set up. Before treatment, IL-6 and TNF-alpha in both groups were higher than the healthy group (P < 0.01) and IL-10 lower than the healthy group (P < 0.01). After treatment, IL-6 and TNF-alpha in both groups decreased (P < 0.01) while IL-10 in treatment group increased. There existed a great difference compared with the control group (P < 0.01). The total effective rate in the treatment group is 92.50% while the control group is 85.71%. thus have a great difference (P < 0.05). During the process of the development of CAP in the elderly, there existed the phenomenon of the excessive release of TNF-alpha, IL-6 and the too much inhibition of IL-10. The unbalance of TNF-alpha, IL-6, IL-10 can be a monitoring index reflecting the severity of the disease. The Chinese medicine Qingfeihuayu soup has obviously have regulating and clinical effect.

  3. Results from the Crystal Ball at DORIS II

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gaiser, J.E.

    1983-10-01

    Results are presented from studies of the inclusive photon spectra in hadronic decays of the UPSILON' and UPSILON and the exclusive channel UPSILON' ..-->.. ..gamma gamma..UPSILON ..-->.. ..cap alpha cap alpha..l/sup +/l/sup -/, by the Crystal Ball detector at DORIS II. We measure two signals in the UPSILON' ..-->.. ..gamma.. + anything inclusive channel at E(..gamma..) == 108.3 +- 0.9 +- 3.0 MeV and at E(..gamma..) == 127.5 +- 1.2 +- 4.0 MeV. Branching ratios obtained for these signals are: BR(UPSILON' ..-->.. ..gamma..(108) + anything) == (6.3 +- 1.3 +- 1.4)% BR(UPSILON' ..-->.. ..gamma..(128) + anything) == (6.0 +- 1.3more » +- 1.4)%.« less

  4. MFTF-. cap alpha. + T progress report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nelson, W.D.

    1985-04-01

    Early in FY 1983, several upgrades of the Mirror Fusion Test Facility (MFTF-B) at Lawrence Livermore National Laboratory (LLNL) were proposed to the fusion community. The one most favorably received was designated MFTF-..cap alpha..+T. The engineering design of this device, guided by LLNL, has been a principal activity of the Fusion Engineering Design Center during FY 1983. This interim progress report represents a snapshot of the device design, which was begun in FY 1983 and will continue for several years. The report is organized as a complete design description. Because it is an interim report, some parts are incomplete; theymore » will be supplied as the design study proceeds. As described in this report, MFTF-..cap alpha..+T uses existing facilities, many MFTF-B components, and a number of innovations to improve on the physics parameters of MFTF-B. It burns deuterium-tritium and has a central-cell Q of 2, a wall loading GAMMA/sub n/ of 2 MW/m/sup 2/ (with a central-cell insert module), and an availability of 10%. The machine is fully shielded, allows hands-on maintenance of components outside the vacuum vessel 24 h after shutdown, and has provisions for repair of all operating components.« less

  5. Treatment of carcinoma in situ of the urinary bladder with an alpha-emitter immunoconjugate targeting the epidermal growth factor receptor: a pilot study.

    PubMed

    Autenrieth, Michael E; Seidl, Christof; Bruchertseifer, Frank; Horn, Thomas; Kurtz, Florian; Feuerecker, Benedikt; D'Alessandria, Calogero; Pfob, Christian; Nekolla, Stephan; Apostolidis, Christos; Mirzadeh, Saed; Gschwend, Jürgen E; Schwaiger, Markus; Scheidhauer, Klemens; Morgenstern, Alfred

    2018-07-01

    Patients with carcinoma in situ (CIS) of the bladder refractory to bacillus Calmette-Guérin (BCG) treatment are usually treated with cystectomy. Therefore, new treatment options with preservation of the urinary bladder are needed. The objective of the study was to investigate the feasibility, safety and efficacy of a novel targeted alpha-emitter immunotherapy for CIS after BCG treatment failure. A pilot study was conducted in 12 patients (age range 64-86 years, ten men, two women) with biopsy-proven CIS of the bladder refractory to BCG treatment. The patients were treated intravesically with a single instillation (one patient was treated twice) of the alpha-emitter 213 Bi coupled to an anti-EGFR antibody (366-821 MBq). The primary aims of the study were to determine the feasibility of treatment with the 213 Bi-immunoconjugate and evaluation of adverse effects. Therapeutic efficacy was monitored by histological mapping of the urinary bladder 8 weeks after treatment and at different time points thereafter. The study proved that intravesical instillation of the 213 Bi-immunoconjugate targeting EGFR is feasible. No adverse effects were observed and all blood and urine parameters determined remained in their normal ranges. Therapeutic efficacy was considered satisfactory, in that three of the 12 patients showed no signs of CIS 44, 30 and 3 months after treatment. Intravesical instillation of 213 Bi-anti-EGFR monoclonal antibody was well tolerated and showed therapeutic efficacy. Repeated instillation and/or instillation of higher activities of the 213 Bi-immunoconjugate might lead to better therapeutic outcomes. A phase I clinical trial is planned.

  6. 223Ra-dichloride spectrometric characterization: Searching for the presence of long-lived isotopes with radiological protection implications.

    PubMed

    Sánchez-Jiménez, J; López-Montes, A; Núñez-Martínez, L; Villa-Abaunza, A; Fraile, L M; Sánchez-Tembleque, V; Udías, J M

    2017-03-01

    223 Ra-dichloride was approved with the commercial name of Xofigo in 2014 for treatment of metastatic castration-resistant prostate cancer. 223 Ra is obtained by neutron irradiation of 226 Ra yielding 227 Ac, which decays to 227 Th and 223 Fr, both decaying to 223 Ra. Since 223 Ra is predominantly (95.3%) an alpha emitter with a 11.42days long half-life, the radiopharmaceutical, its remnants, the patient, and waste material can be managed and disposed with low radiation protection requirements. 227 Ac is a long-lived (T 1/2 =21.77years) beta emitter that demands strong radiation protection measures. In particular waste disposal has to follow the International Atomic Energy Agency (IAEA) and European Commission (EC) regulations. Since 227 Ac is involved in the production of 223 Ra, an impurity analysis of each batch is required after production. Due to time restrictions, the manufacturer's detection limit (<0.001%) exceeds the one required to assure that 227 Ac concentrations are below direct disposal levels. To improve the detection limit, long-term accurate spectroscopy is required. Alpha and gamma spectroscopy measurements were carried out at the Complutense University Nuclear Physics Laboratory. After twelve months follow up of a sample, 227 Ac concentration was found to be smaller than 10 -9 . This allows for direct waste disposal and no additional radiation protection restrictions than those required for 223 Ra. The presence of contamination by other radioisotopes was also ruled out by this experiment. Specifically 226 Ra, involved in 223 Ra production as the original parent and with a very long-lived (T 1/2 =1577years) alpha emitter, was also below the experimental detection limit. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  7. A method for the assessment of specific energy distribution in a model tumor system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Noska, M.A.

    1996-12-31

    Due to the short range of alpha particles in tissue, the calculation of dose from internally deposited alpha emitters requires a detailed analysis of the microscopic distribution of the radionuclide in order to determine the spatial distribution of energy emission events and, from this, the spatial distribution of dose. In the present study, the authors used quantitative autoradiography (QAR) to assess the microdistribution of a radiolabeled monoclonal antibody (MAb) fragment in human glioma xenografts in mice.

  8. Muscarinic cholinergic and alpha/sub 1/ adrenergic receptors in murine atria: phosphatidylinositol breakdown and receptor interaction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scherer, R.W.

    Upon stimulation of muscarinic cholinergic receptors, there is a decrease in the force of contraction rate of firing in heart, while stimulation of ..cap alpha.. adrenergic receptors causes an increase in the force of contraction with no change in the heart rate. Yet both receptors stimulate the breakdown of phosphatidylinositol (PI). Therefore, the breakdown of PI was examined to determine how the process differed between the two receptor systems. Murine atria, prelabelled with (/sup 3/H)inositol, were stimulated with the muscarinic cholinergic agonists, carbamylcholine (CARB), and oxotremorine (OXO); and with the ..cap alpha.. adrenergic agonists, norepinephrine (NE) and phenylephrine (PE); eithermore » singly or in combination. Breakdown of PI was assessed by measurement of individual inositol phosphates by anion exchange chromatography. Binding of CARB to atrial muscarinic receptors was measured by competition with (/sup 3/H)quinuclidinyl benzilate.« less

  9. Structural and biological characterization of a capsular polysaccharide produced by Staphylococcus haemolyticus.

    PubMed

    Flahaut, Sigrid; Vinogradov, Evgeny; Kelley, Kathryn A; Brennan, Shannon; Hiramatsu, Keiichi; Lee, Jean C

    2008-03-01

    The DNA sequence of the genome of Staphylococcus haemolyticus JCSC1435 revealed a putative capsule operon composed of 13 genes in tandem. The first seven genes (capABCDEFG(Sh)) showed > or = 57% similarity with the Staphylococcus aureus cap5 or cap8 locus. However, the capHIJKLM(Sh) genes are unique to S. haemolyticus and include genes encoding a putative flippase, an aminotransferase, two glycosyltransferases, and a transcriptional regulator. Capsule-like material was readily apparent by immunoelectron microscopy on bacteria harvested in the postexponential phase of growth. Electron micrographs of a JCSC1435 mutant with a deleted cap region lacked the capsule-like material. Both strains produced small amounts of surface-associated material that reacted with antibodies to polyglutamic acid. S. haemolyticus cap genes were amplified from four of seven clinical isolates of S. haemolyticus from humans, and three of these strains produced a serologically cross-reactive capsular polysaccharide. In vitro assays demonstrated that the acapsular mutant strain showed greater biofilm formation but was more susceptible to complement-mediated opsonophagocytic killing than the parent strain. Structural characterization of capsule purified from S. haemolyticus strain JCSC1435 showed a trisaccharide repeating unit: -3-alpha-L-FucNAc-3-(2-NAc-4-N-Asp-2,4,6-trideoxy-beta-D-Glc)-4-alpha-D-GlcNAc-. This structure is unique among staphylococcal polysaccharides in that its composition includes a trideoxy sugar residue with aspartic acid as an N-acyl substituent.

  10. Absolute configuration of a chiral CHD group via neutron diffraction: confirmation of the absolute stereochemistry of the enzymatic formation of malic acid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bau, R.; Brewer, I.; Chiang, M.Y.

    Neutron diffraction has been used to monitor the absolute stereochemistry of an enzymatic reaction. (-)(2S)malic-3-d acid was prepared by the action of fumarase on fumaric acid in D/sub 2/O. After a large number of cations were screened, it was found that (+)(R)..cap alpha..-phenylethylamine forms the large crystals necessary for a neutron diffraction analysis. The subsequent structure determination showed that (+)(R)..cap alpha..-phenylethylammonium (-)(2S)malate-3-d has an absolute configuration of R at the CHD site. This result confirms the absolute stereochemistry of fumarate-to-malate transformation as catalyzed by the enzyme fumarase.

  11. Performances of the Alpha-X RF gun on the PHIL accelerator at LAL

    NASA Astrophysics Data System (ADS)

    Vinatier, T.; Bruni, C.; Roux, R.; Brossard, J.; Chancé, S.; Cayla, J. N.; Chaumat, V.; Xu, G.; Monard, H.

    2015-10-01

    The Alpha-X RF-gun was designed to produce an ultra-short (<100 fs rms), 100 pC and 6.3 MeV electron beam with a normalized rms transverse emittance of 1π mm mrad for a gun peak accelerating field of 100 MV/m. Such beams will be required by the Alpha-X project, which aims to study a laser-driven plasma accelerator with a short wavelength accelerating medium. It has been demonstrated on PHIL (Photo-Injector at LAL) that the coaxial RF coupling, chosen to preserve the gun field cylindrical symmetry, is perfectly understood and allows reaching the required peak accelerating field of 100 MV/m giving beam energy of 6.3 MeV. Moreover, a quite low beam rms relative energy spread of 0.15% at 3.8 MeV has been measured, completely agreeing with simulations. Dark current, quantum efficiencies and dephasing curves measurements have also been performed. They all show high values of the field enhancement factor β, which can be explained by the preparation of the photocathodes. Finally, measurements on the transverse phase-space have been carried out, with some limitations given by the difficult modelization of one of the PHIL solenoid magnets and by the enlargement of the beam transverse dimensions due to the use of YAG screens. These measurements give a normalized rms transverse emittance around 5π mm mrad, which does not fulfill the requirement for the Alpha-X project.

  12. Oxidation and emittance of superalloys in heat shield applications

    NASA Technical Reports Server (NTRS)

    Wiedemann, K. E.; Clark, R. K.; Unnam, J.

    1986-01-01

    Recently developed superalloys that form alumina coatings have a high potential for heat shield applications for advanced aerospace vehicles at temperatures above 1095C. Both INCOLOY alloy MA 956 (of the Inco Alloys International, Inc.), an iron-base oxide-dispersion-strengthened alloy, and CABOT alloy No. 214 (of the Cabot Corporation), an alumina-forming nickel-chromium alloy, have good oxidation resistance and good elevated temperature strength. The oxidation resistance of both alloys has been attributed to the formation of a thin alumina layer (alpha-Al2O3) at the surface. Emittance and oxidation data were obtained for simulated Space Shuttle reentry conditions using a hypersonic arc-heated wind tunnel. The surface oxides and substrate alloys were characterized using X-ray diffraction and scanning and transmission electron microscopy with an energy-dispersive X-ray analysis unit. The mass loss and emittance characteristics of the two alloys are discussed.

  13. Role of carotenoids in the phototropic response of corn seedings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vierstra, R.D.; Poff, K.L.

    1981-10-01

    The herbicide 4 chloro-5-(methylamino)-2-..cap alpha..,..cap alpha..,..cap alpha..,-trifluoro-m-tolyl)-3(2H)- pyridazinone (SAN 9789), which blocks the synthesis in higher plants of colored carotenoids but not of flavins, was used to examine the involvement of carotenoids in corn seeding phototropism. It was concluded that ''bulk'' carotenoids are not the photoreceptor pigment based on the results that increasing concentrations of SAN 9789 (up to 100 micromolar) did not alter the phototropic sensitivity to 380 nanometers light (using geotropism as a control) and did not increase the threshold intensities of fluence response curves for both 380 and 450 nanometers light even though carotenoid content was reducedmore » to 1 to 2% of normal. SAN 9789 treatment, however, did reduce seedling sensitivity toward 450 nanometers light indicating that carotenoids are involved in phototropism. Carotenoids, which are located mainly in the primary leaves, may act in phototropism as an internal screen, enhancing the light intensity gradient across the seedling and thus contributing to the ability of the seedling to perceive light direction. These results, indicate that the action spectra for phototropic responses can be significantly affected by the absorbance of screening pigments in vivo thus altering its shape from the in vitro absorption spectrum of the photoreceptor pigment.« less

  14. Secondary. cap alpha. -deuterium kinetic isotope effects in solvolyses of ferrocenylmethyl acetate and benzoate in ethanol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sutic, D.; Asperger, S.; Borcic, S.

    1982-12-17

    Secondary ..cap alpha..-deuterium kinetic isotope effects (KIE) in solvolyses of ferrocenyldideuteriomethyl acetate and benzoate were determined in 96% (v/v) ethanol, at 25/sup 0/C, as k/sub H//k/sub D/ = 1.24 and 1.26, respectively. The KIEs were also determined in the presence of 0.1 mol dm/sup -3/ lithium perchlorate: the k/sub H//k/ sub D/ values were 1.23 and 1.22 for acetate and benzoate complexes, respectively. The maximum KIE for the C-O bond cleavage of a primary substrate is as large as, or larger than, that of secondary derivatives, which is estimated to be 1.23 per deuterium. The measured KIE of about 12%more » per D therefore represents a strongly reduced effect relative to its maximum. The solvolyses exhibit ''a special salt effect''. This effect indicates the presence of solvent-separated ion pairs and the return to tight pairs. As the maximum KIE is expected in solvolyses involving transformation of one type of ion pair into another, the strongly reduced ..cap alpha..-D KIE supports the structure involving direct participation of electrons that in the ground state are localized at the iron atom. The alkyl-oxygen cleavage is accompanied by 10-15% acyl-oxygen cleavage.« less

  15. Hydrogen transport and hydrogen embrittlement in stainless steels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perng, T.P.

    1985-01-01

    In order to understand the kinetics of gaseous hydrogen-induced slow crack growth (SCG) in metastable austenitic stainless steels, hydrogen permeation and/or cracking velocity were measured and compared for three types of stainless steels. These included austenitic, ferritic, and duplex (..gamma../..cap alpha..) alloys. Deformation in AISI 301 resulted in various amounts of ..cap alpha..' martensite, which enhanced the effective hydrogen diffusivity and permeability. No phase transformation was observed in deformed AISI 310. The effective hydrogen diffusivity in this alloy was slightly reduced after plastic deformation, presumably by dislocation trapping. In either the dynamic or static tensile test, AISI 301 exhibited themore » greatest hydrogen embrittlement and therefore the highest SCG velocity among all the alloys tested in this work. The SCG velocity was believed to be controlled by the rate of accumulation of hydrogen in the embrittlement region ahead of the crack tip and therefore could be explained with the hydrogen transport parameters measured from the permeation experiments. The relatively high SCG velocity in AISI 301 was probably due to the fast transport of hydrogen through the primarily stress-induced ..cap alpha..' phase around the crack. No SCG was observed in AISI 310. The presence of H/sub 2/O vapor was found to reduce both the hydrogen permeation and SCG velocity.« less

  16. Vacuum energy density near static distorted black holes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frolov, V.P.; Sanchez, N.

    1986-03-15

    We investigate the contribution of massless fields of spins 0, 1/2, and 1 to the vacuum polarization near the event horizon of static Ricci-flat space-times. We do not assume any particular spatial symmetry. Within the Page-Brown ''ansatz'' we calculate /sup ren/ and /sup ren/ near static distorted black holes, for both the Hartle-Hawking (Vertical Bar>/sub H/) and Boulware (Vertical Bar>/sub B/) vacua. Using Israel's description of static space-times, we express these quantities in an invariant geometric way. We obtain that /sub H//sup ren/ and /sub H//sup ren/ near the horizon depend only on the two-dimensional geometry of the horizon surface.more » We find /sub H//sup ren/ = (1/48..pi../sup 2/ )K/sub 0/, /sub H//sup ren/ = (7..cap alpha..+12..beta.. )K/sub 0/ /sup 2/-..cap alpha../sup(/sup 2/)..delta..K/sub 0/. $K sub 0: is the Gaussian curvature of the horizon, and ..cap alpha.. and ..beta.. are numerical coefficients depending on the spin of a field. The term in /sup(/sup 2/)..delta..K/sub 0/ is characteristic of the distortion of the black hole. When the event horizon is not distorted, K/sub 0/ is a constant and this term disappears.« less

  17. GaAs droplet quantum dots with nanometer-thin capping layer for plasmonic applications.

    PubMed

    Park, Suk In; Trojak, Oliver Joe; Lee, Eunhye; Song, Jin Dong; Kyhm, Jihoon; Han, Ilki; Kim, Jongsu; Yi, Gyu-Chul; Sapienza, Luca

    2018-05-18

    We report on the growth and optical characterization of droplet GaAs quantum dots (QDs) with extremely-thin (11 nm) capping layers. To achieve such result, an internal thermal heating step is introduced during the growth and its role in the morphological properties of the QDs obtained is investigated via scanning electron and atomic force microscopy. Photoluminescence measurements at cryogenic temperatures show optically stable, sharp and bright emission from single QDs, at visible wavelengths. Given the quality of their optical properties and the proximity to the surface, such emitters are good candidates for the investigation of near field effects, like the coupling to plasmonic modes, in order to strongly control the directionality of the emission and/or the spontaneous emission rate, crucial parameters for quantum photonic applications.

  18. GaAs droplet quantum dots with nanometer-thin capping layer for plasmonic applications

    NASA Astrophysics Data System (ADS)

    In Park, Suk; Trojak, Oliver Joe; Lee, Eunhye; Song, Jin Dong; Kyhm, Jihoon; Han, Ilki; Kim, Jongsu; Yi, Gyu-Chul; Sapienza, Luca

    2018-05-01

    We report on the growth and optical characterization of droplet GaAs quantum dots (QDs) with extremely-thin (11 nm) capping layers. To achieve such result, an internal thermal heating step is introduced during the growth and its role in the morphological properties of the QDs obtained is investigated via scanning electron and atomic force microscopy. Photoluminescence measurements at cryogenic temperatures show optically stable, sharp and bright emission from single QDs, at visible wavelengths. Given the quality of their optical properties and the proximity to the surface, such emitters are good candidates for the investigation of near field effects, like the coupling to plasmonic modes, in order to strongly control the directionality of the emission and/or the spontaneous emission rate, crucial parameters for quantum photonic applications.

  19. Measuring the Stellar Populations of Individual Lyman Alpha Emitters During the Epoch of Peak Star Formation

    NASA Astrophysics Data System (ADS)

    Reddy, Naveen

    2010-09-01

    Selecting galaxies by their strong Lyman-alpha emission provides a powerful means of probing the reionization epoch and the faint/low-mass galaxies that dominate star formation at high redshift. Yet, our understanding of high-redshift Lyman-alpha emitters {LAEs} has lagged behind that of other well-studied populations {e.g., Lyman break galaxies} due to their continuum faintness and the shifting of age/mass-sensitive features into the near-IR where the high terrestrial background inhibits deep observations. All existing studies of LAEs at z>2 have used stacked optical and/or Spitzer infrared data to discern their median properties, but the actual distributions of ages, reddenings, and stellar masses for these populations are poorly characterized. To fill this glaring gap in the observations and advance our understanding of this important population, we propose WFC3/IR+F160W imaging of fields where we have conducted a survey of low redshift {z 1.9} Lyman-alpha emitters {LAEs}, in order to measure their ages and stellar masses at an epoch where such observations directly probe the age-sensitive Balmer/4000 AA breaks. The targeted sample will include 45-50 spectroscopically confirmed LAEs at z=1.7-2.1 and roughly twice as many candidates, making it the largest sample of homogeneously selected LAEs with individual measurements of the ages, masses, and dust extinction. With these data we will {1} carefully take into account the age-dependence of the extinction curve to make robust comparisons between LAEs and continuum-selected galaxies at the same redshifts; {2} combine clustering and stellar mass measurements to infer the duty cycles of LAEs and determine if they are triggered in the presence of large-scale structures; and {3} quantify the importance of the LAE phase at different galaxy luminosity and mass scales, over a large dynamic range in these properties. An economical investment of just 12 orbits will allow us to accomplish these goals, and remains the only hope of efficiently studying such low luminosity high-redshift galaxies in the near-IR prior to the JWST-era.

  20. Alpha Decay Potential Barriers and Half-Lives and Analytical Formula Predictions for Superheavy Nuclei

    NASA Astrophysics Data System (ADS)

    Royer, Guy; Zhang, Hongfei

    The α decay potential barriers are determined in the cluster-like shape path within a generalized liquid drop model including the proximity effects between the α particle and the daughter nucleus and adjusted to reproduce the experimental Qα. The α emission half-lives are determined within the WKB penetration probability. Calculations using previously proposed formulae depending only on the mass and charge of the alpha emitter and Qα are also compared with new experimental alpha-decay half-lives. The agreement allows to provide predictions for the α decay half-lives of other still unknown superheavy nuclei using the Qα determined from the 2003 atomic mass evaluation of Audi, Wapstra and Thibault.

  1. Variable anodic thermal control coating

    NASA Technical Reports Server (NTRS)

    Gilliland, C. S.; Duckett, J. (Inventor)

    1983-01-01

    A process for providing a thermal control solar stable surface coating for aluminum surfaces adapted to be exposed to solar radiation wherein selected values within the range of 0.10 to 0.72 thermal emittance (epsilon sub tau) and 0.2 to 0.4 solar absorptance (alpha subs) are reproducibly obtained by anodizing the surface area in a chromic acid solution for a selected period of time. The rate voltage and time, along with the parameters of initial epsilon sub tau and alpha subs, temperature of the chromic acid solution, acid concentration of the solution and the material anodized determines the final values of epsilon/tau sub and alpha sub S. 9 Claims, 5 Drawing Figures.

  2. Skeletal dosimetry models for alpha-particles for use in molecular radiotherapy

    NASA Astrophysics Data System (ADS)

    Watchman, Christopher J.

    Molecular radiotherapy is a cancer treatment methodology whereby a radionuclide is combined with a biologically active molecule to preferentially target cancer cells. Alpha-particle emitting radionuclides show significant potential for use in molecular radiotherapy due to the short range of the alpha-particles in tissue and their high rates of energy deposition. Current radiation dosimetry models used to assess alpha emitter dose in the skeleton were developed originally for occupational applications. In medical dosimetry, individual variability in uptake, translocation and other biological factors can result in poor correlation of clinical outcome with marrow dose estimates determined using existing skeletal models. Methods presented in this work were developed in response to the need for dosimetry models which account for these biological and patient-specific factors. Dosimetry models are presented for trabecular bone alpha particle dosimetry as well as a model for cortical bone dosimetry. These radiation transport models are the 3D chord-based infinite spongiosa transport model (3D-CBIST) and the chord-based infinite cortical transport model (CBICT), respectively. Absorbed fraction data for several skeletal tissues for several subjects are presented. Each modeling strategy accounts for biological parameters, such as bone marrow cellularity, not previously incorporated into alpha-particle skeletal dosimetry models used in radiation protection. Using these data a study investigating the variability in alpha-particle absorbed fractions in the human skeleton is also presented. Data is also offered relating skeletal tissue masses in individual bone sites for a range of ages. These data are necessary for dose calculations and have previously only been available as whole body tissue masses. A revised 3D-CBIST model is also presented which allows for changes in endosteum thickness to account for revised target cell location of tissues involved in the radiological induction of bone cancer. In addition, new data are presented on the location of bone-marrow stem cells within the marrow cavities of trabecular bone of the pelvis. All results presented in this work may be applied to occupational exposures, but their greatest utility lies in dose assessments for alpha-emitters in molecular radiotherapy.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Calva-Tellez, E.; Yennie, D.R.

    The Coulomb corrections of relative order Z..cap alpha.. to inelastic electron and muon scattering are examined. Although individual terms are large, the net result is too small to be experimentally significant.

  4. Final Report for grant entitled "Production of Astatine-211 for U.S. Investigators"

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilbur, Daniel Scott

    2012-12-12

    Alpha-particle emitting radionuclides hold great promise in the therapy of cancer, but few alpha-emitters are available to investigators to evaluate. Of the alpha-emitters that have properties amenable for use in humans, 211At is of particular interest as it does not have alpha-emitting daughter radionuclides. Thus, there is a high interest in having a source of 211At for sale to investigators in the US. Production of 211At is accomplished on a cyclotron using an alpha-particle beam irradiation of bismuth metal. Unfortunately, there are few cyclotrons available that can produce an alpha particle beam for that production. The University of Washington hasmore » a cyclotron, one of three in the U.S., that is currently producing 211At. In the proposed studies, the things necessary for production and shipment of 211At to other investigators will be put into place at UW. Of major importance is the efficient production and isolation of 211At in a form that can be readily used by other investigators. In the studies, production of 211At on the UW cyclotron will be optimized by determining the best beam energy and the highest beam current to maximize 211At production. As it would be very difficult for most investigators to isolate the 211At from the irradiated target, the 211At-isolation process will be optimized and automated to more safely and efficiently obtain the 211At for shipment. Additional tasks to make the 211At available for distribution include obtaining appropriate shipping vials and containers, putting into place the requisite standard operating procedures for Radiation Safety compliance at the levels of 211At activity to be produced / shipped, and working with the Department of Energy, Isotope Development and Production for Research and Applications Program, to take orders, make shipments and be reimbursed for costs of production and shipment.« less

  5. Removal of plutonium and americium from alkaline waste solutions

    DOEpatents

    Schulz, Wallace W.

    1979-01-01

    High salt content, alkaline waste solutions containing plutonium and americium are contacted with a sodium titanate compound to effect removal of the plutonium and americium from the alkaline waste solution onto the sodium titanate and provide an effluent having a radiation level of less than 10 nCi per gram alpha emitters.

  6. An Alternative to NOx Cap-and-Trade Programs: An Exploratory Analysis of Charging NOx Emitters for Health Damages

    NASA Astrophysics Data System (ADS)

    Mauzerall, D. L.; Sultan, B.; Kim, N.; Bradford, D.

    2003-12-01

    To address the problem of elevated O3 concentrations throughout the northeastern United States in summer, a NOx cap-and-trade program was implemented that reduced NOx emissions from large point sources by nearly 50%. To determine whether this program has been successful, we examine O3, NO and temperature measurements collected in the EPA-AIRS network prior to and after the cap-and-trade program went into effect in 1999. Ambient NO concentrations as measured in the EPA-AIRS network are lower in the post-cap period in all months except July. We find that the upper half of the distribution of O3 concentrations within the region is essentially unchanged (or slightly higher) in May and June, modestly reduced in July and August (except the highest concentrations which are larger in August), and significantly lower in September (ranging from 0-20 ppb lower between the mean and highest concentrations) in the 1999-2001 post-cap period relative to the 1995-1998 pre-cap period. Except for September, the frequency with which the 80ppb 8-hour NAAQS standard for O3 is exceeded has not decreased. Temperatures during the post-cap period were slightly higher in June, July and August, and slightly lower in September - likely contributing to reduced O3 levels during September in the post-cap period. To explore the possibility that trading, or selective emissions over the course of the summer, could influence regional O3 concentrations, we conduct chemical transport modeling experiments using the CAMx regional model. Even within May-September for a single year, demands for electrical power and hence NOx emissions are greater during hot than cool periods. We demonstrate that substantially more O3 is produced from identical NOx emissions from a single power plant on high temperature than on low temperature days in July 1995. Thus a lack of temporal restrictions on when in a single summer month NOx emissions may occur can result in higher O3 levels. We also demonstrate that identical NOx emissions in regions of high (low) isoprene emission result in greater (lesser) O3 production. This indicates that NOx trades from locations with low to high isoprene emissions likely result in increases in O3 production. Since the objective of reducing O3 concentrations is to reduce the impact elevated O3 has on human health and welfare, we examine the mortalities that result from the O3 produced from a fixed NOx emission in the two cases described above as well as in regions of high and low population. We estimate substantially higher mortality rates from a unit NOx emission as a result of elevated O3 concentrations for high temperature days, in regions of high isoprene emissions, and for emissions occurring upwind of large populations. We attempt to assign a monetary value to the loss of life resulting from the enhanced O3 concentrations that result from these NOx emissions. We propose, as an alternative to NOx emissions cap and trade programs, a system by which NOx emitters are charged for the marginal damage they cause as a result of the O3 produced from the NOx they emit. Rather than resulting in a reduction in total NOx emissions without necessarily reducing O3 concentrations (as a cap-and-trade program does), this alternative system provides a direct incentive to reduce NOx emissions at times and places where they cause the most harm.

  7. Neutrophil-derived alpha defensins control inflammation by inhibiting macrophage mRNA translation

    PubMed Central

    Tomlinson, Gareth H.; Miles, Katherine; Smith, Richard W. P.; Rossi, Adriano G.; Hiemstra, Pieter S.; van ’t Wout, Emily F. A.; Dean, Jonathan L. E.; Gray, Nicola K.; Lu, Wuyuan; Gray, Mohini

    2016-01-01

    Neutrophils are the first and most numerous cells to arrive at the site of an inflammatory insult and are among the first to die. We previously reported that alpha defensins, released from apoptotic human neutrophils, augmented the antimicrobial capacity of macrophages while also inhibiting the biosynthesis of proinflammatory cytokines. In vivo, alpha defensin administration protected mice from inflammation, induced by thioglychollate-induced peritonitis or following infection with Salmonella enterica serovar Typhimurium. We have now dissected the antiinflammatory mechanism of action of the most abundant neutrophil alpha defensin, Human Neutrophil Peptide 1 (HNP1). Herein we show that HNP1 enters macrophages and inhibits protein translation without inducing the unfolded-protein response or affecting mRNA stability. In a cell-free in vitro translation system, HNP1 powerfully inhibited both cap-dependent and cap-independent mRNA translation while maintaining mRNA polysomal association. This is, to our knowledge, the first demonstration of a peptide released from one cell type (neutrophils) directly regulating mRNA translation in another (macrophages). By preventing protein translation, HNP1 functions as a “molecular brake” on macrophage-driven inflammation, ensuring both pathogen clearance and the resolution of inflammation with minimal bystander tissue damage. PMID:27044108

  8. Assessment of posttraumatic stress disorder in Cambodian refugees using the Clinician-Administered PTSD Scale: psychometric properties and symptom severity.

    PubMed

    Hinton, Devon E; Chhean, Dara; Pich, Vuth; Pollack, M H; Orr, Scott P; Pitman, Roger K

    2006-06-01

    Posttraumatic stress disorder (PTSD) symptoms were assessed by using the Clinician-Administered PTSD Scale (CAPS) in a consecutive sample of Cambodian refugees attending a psychiatric clinic in the United States. Psychometric properties of the translated CAPS and severity of PTSD-related symptoms were examined. The CAPS demonstrated adequate psychometric properties, including coefficient alpha (.92) and item-total correlations (.48-.85). Of the sample 56% (101/179) met Diagnostic and Statistical Manual of Mental Disorders, fourth edition, criteria for current PTSD. Those patients who met criteria for current PTSD had significantly higher CAPS total scores (M = 65.3, SD = 18.1) than those who did not meet the criteria (M = 13.9, SD = 16.7).

  9. Alpha decay calculations with a new formula

    NASA Astrophysics Data System (ADS)

    Akrawy, D. T.; Poenaru, D. N.

    2017-10-01

    A new semi-empirical formula for calculations of α decay half-lives is presented. It was derived from the Royer relationship by introducing new parameters which are fixed by fit to a set of experimental data. We are using three sets: set A with 130 e-e (even-even), 119 e-o (even-odd), 109 o-e, and 96 o-o, set B with 188 e-e, 147 e-o, 131 o-e and 114 o-o, and set C with 136 e-e, 84 e-o, 76 o-e and 48 o-o alpha emitters. A comparison of results obtained with the new formula (newF) and the following well known relationships: semiempirical relationship based on fission theory (semFIS), analytical superasymmetric fission (ASAF) model and universal formula (UNIV) made in terms of rms standard deviation. We also introduced a weighted mean value of this quantity, allowing us to compare the global properties of a given model. For set B the order of the four models is the following: semFIS, UNIV, newF and ASAF. Nevertheless for even-even alpha emitters, UNIV gives the second best result after semFIS, and for odd-even parents the second is newF. Despite its simplicity in comparison with semFIS, newF, presented in this article, behaves quite well, competing with the other well known relationships.

  10. Radioactivity in food crops

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Drury, J.S.; Baldauf, M.F.; Daniel, E.W.

    Published levels of radioactivity in food crops from 21 countries and 4 island chains of Oceania are listed. The tabulation includes more than 3000 examples of 100 different crops. Data are arranged alphabetically by food crop and geographical origin. The sampling date, nuclide measured, mean radioactivity, range of radioactivities, sample basis, number of samples analyzed, and bibliographic citation are given for each entry, when available. Analyses were reported most frequently for /sup 137/Cs, /sup 40/K, /sup 90/Sr, /sup 226/Ra, /sup 228/Ra, plutonium, uranium, total alpha, and total beta, but a few authors also reported data for /sup 241/Am, /sup 7/Be,more » /sup 60/Co, /sup 55/Fe, /sup 3/H, /sup 131/I, /sup 54/Mn, /sup 95/Nb, /sup 210/Pb, /sup 210/Po, /sup 106/Ru, /sup 125/Sb, /sup 228/Th, /sup 232/Th, and /sup 95/Zr. Based on the reported data it appears that radioactivity from alpha emitters in food crops is usually low, on the order of 0.1 Bq.g/sup -1/ (wet weight) or less. Reported values of beta radiation in a given crop generally appear to be several orders of magnitude greater than those of alpha emitters. The most striking aspect of the data is the great range of radioactivity reported for a given nuclide in similar food crops with different geographical origins.« less

  11. Effects of preventing O-glycosylation on the secretion of human chorionic gonadotropin in Chinese hamster ovary cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matzuk, M.M.; Krieger, M.; Corless, C.L.

    1987-09-01

    Human chorionic gonadotropin (hCG) is a member of a family of heterodimeric glycoprotein hormones that have a common ..cap alpha.. subunit but differ in their hormone-specific ..beta..-subunits. The ..beta.. subunit of hCG (hCG..beta..) is unique among the ..beta.. subunits in that it contains four mucin-like O-linked oligosaccharides attached to a carboxyl-terminal extension. To study the effects of O-glycosylation on the secretion and assembly of hCG, expression vectors containing either hCG..beta.. gene alone or together with the hCG..cap alpha.. gene were transfected into a mutant Chinese hamster ovary cell line, 1d1D, which exhibits a reversible defect in O-glycosylation. The results revealmore » that hCG..beta.. can be secreted normally in the absence of its O-linked oligosaccharides. hCG..beta.. devoid of O-linked carbohydrate can also combine efficiently with hCG..cap alpha.. and be secreted as an intact dimer. The authors conclude that in Chinese hamster ovary cells, the hCG..beta.. O-linked chains play no role in the assembly and secretion of hCG. The normal and O-linked oligosaccharide-deficient forms of hCG secreted by these cells should prove useful in examining the role of O-linked chains on the biological function of hCG.« less

  12. Hormonal regulation of hepatic glycogenolysis in the carp, Cyprinus carpio

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Janssens, P.A.; Lowrey, P.

    1987-04-01

    Carp (Cyprinus carpio) liver maintained normal glycogen content and enzyme complement for several days in organ culture. Epinephrine-stimulated glycogenolysis, phosphorylase activation, and cyclic AMP (cAMP) accumulation in a concentration-dependent manner with EC/sub 50/s of 100, 100, and 500 nM, respectively. These actions were blocked by the ..beta..-adrenergic antagonist, propranolol, but not by the ..cap alpha..-adrenergic antagonist phentolamine. Glycogenolysis and tissue cAMP were uninfluenced by 10/sup -6/ M arginine vasotocin, arginine vasopressin, lysine vasotocin, lysine vasopressin, mesotocin, or oxytocin, but were slightly increased by 10/sup -5/ M isotocin and slightly decreased by 10/sup -6/ M angiotensin II. (/sup 125/I)-iodocyanopindolol (ICP), amore » ..beta..-adrenergic ligand, bound to isolated carp liver membranes with a K/sub D/ of 83 pM. Maximum binding of 45 fmol/mg protein was at 600 pM. Propranolol, isoprenaline, epinephrine, phenylephrine, norepinephrine, and phenoxybenzamine displaced ICP with K/sub D/s of 100 nM, 2, 20, 20, 60, and 200 ..mu..M, respectively. The ..cap alpha..-adrenergic antagonists, yohimbine and prazosin, showed no specific binding. These data provide evidence that catecholamines act via ..beta..-adrenergic receptors in carp liver and that ..cap alpha..-adrenergic receptors are not present. Vasoactive peptides play no significant role in regulation of carp liver glycogenolysis.« less

  13. Hydrogen and deuterium in the local interstellar medium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Murthy, J.N.

    1987-01-01

    This work reports on the results of a series of IUE observations of interstellar HI and DI Ly..cap alpha.. absorption against the chromospheric Ly..cap alpha.. emission of the nearby late-type stars ..cap alpha.. Cen B(1.3 pc), epsilon Eri (3.3 pc), Procyon (3.5 pc), Altair (5.1 pc), Capella (13.2 pc), and HR 1099 (33 pc). The density, velocity dispersion, and bulk velocity of the neutral hydrogen along the line of sight to each of these stars was derived. Lower limits were placed on the deuterium-to-hydrogen (D/H) ratio towards the same stars. These IUE results are generally consistent with previous observations ofmore » the same stars with the Copernicus satellite showing that this modeling procedure is independent of stellar variations over a period of several years. The HI absorption profile towards Altair shows a broad saturated core and steep line wings, consistent with a multicomponent interstellar medium in that direction. The bulk velocities towards the other stars are consistent with a bulk flow from the approximate direction of the galactic center but do show local variations from a uniform flow, possibly indicating a complicated velocity structure even in the solar neighborhood. Interstellar deuterium is detected towards every star except Altair and the derived values for the D/H ratio are consistent with those previously found with Copernicus.« less

  14. Asparagine-linked oligosaccharides on lutropin, follitropin, and thyrotropin: distributions of sulfated and sialylated oligosaccharides on bovine, ovine, and human pituitary glycoprotein hormones

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Green, E.D.; Baenziger, J.U.

    1988-01-05

    The asparagine-linked oligosaccharides on the pituitary glycoprotein hormones lutropin (LH), follitropin (FSH), and thyrotropin (TSH) consist of a heterogeneous array of neutral, sulfated, sialylated, and sulfated/sialylated structures. In this study, the authors determined the relative quantities of the various asparagine-linked oligosaccharides on LH, FSH, and TSH from these three animal species. The proportions of sulfated versus sialylated oligosaccharides varied markedly among the different hormones. Both hormone- and animal species-specific differences in the types and distributions of sulfated, sialylated, and sulfated/sialylated structures were evident. In particular, LH and FSH, which are synthesized in the same pituitary cell and bear ..cap alpha..-subunitsmore » with the identical amino acid sequence, contained significantly different distributions of sulfated and sialylated oligosaccharides. For all three animal species, the ratio of sialylated to sulfated oligosaccharides differed by >10-fold for LH and FSH, with sulfated structures dominating on LH and sialylated structures on FSH. Sialylated oligosaccharides were also heterogeneous with respect to sialic acid linkage (..cap alpha..2,3 versus ..cap alpha..2,6). The differences in oligosaccharide structures among the various pituitary glycoprotein hormones as well as among the various glycosylation sites within a single hormone support the hypothesis that glycosylation may serve important functional roles in the expression and/or regulation of hormone bioactivity.« less

  15. Effects of dietary saw palmetto on the prostate of transgenic adenocarcinoma of the mouse prostate model (TRAMP).

    PubMed

    Wadsworth, Teri L; Worstell, Teresa R; Greenberg, Norman M; Roselli, Charles E

    2007-05-01

    Several of the proposed mechanisms for the actions of the liposterolic extract of saw palmetto (SPE) are exerted on known risk factors for prostate cancer (CaP). This study investigated whether SPE could prevent the progression of CaP in a transgenic adenocarcinoma of the mouse prostate (TRAMP) model. Two different doses of SPE designed to deliver 50 mg/kg/day SPE and 300 mg/kg/day SPE were administered in a custom diet to TRAMP mice for 12 or 24 weeks. Body and organ weights were used to evaluate toxicity, and radioimmunoassay was used to measure plasma and tissue androgen levels to monitor effects of SPE on 5alpha reductase activity. Prostate tissues were evaluated histologically to determine the effect of treatment on tumor grade, cell proliferation, and apoptosis. Treatment with 300 mg/kg/day SPE from 4 to 24 weeks of age significantly reduced the concentration of 5alpha-dihydrotestosterone (DHT) in the prostate and resulted in a significant increase in apoptosis and significant decrease in pathological tumor grade and frank tumor incidence. Dietary supplementation with SPE may be effective in controlling CaP tumorigenesis. SPE suppression of prostatic DHT levels lends support to the hypothesis that inhibition of the enzyme 5alpha-reductase is a mechanism of action of this substance. (c) 2007 Wiley-Liss, Inc.

  16. Expanded turn conformations: characterization and sequence-structure correspondence in alpha-turns with implications in helix folding.

    PubMed

    Dasgupta, Bhaskar; Pal, Lipika; Basu, Gautam; Chakrabarti, Pinak

    2004-05-01

    Like the beta-turns, which are characterized by a limiting distance between residues two positions apart (i, i+3), a distance criterion (involving residues at positions i and i+4) is used here to identify alpha-turns from a database of known protein structures. At least 15 classes of alpha-turns have been enumerated based on the location in the phi,psi space of the three central residues (i+1 to i+3)-one of the major being the class AAA, where the residues occupy the conventional helical backbone torsion angles. However, moving towards the C-terminal end of the turn, there is a shift in the phi,psi angles towards more negative phi, such that the electrostatic repulsion between two consecutive carbonyl oxygen atoms is reduced. Except for the last position (i+4), there is not much similarity in residue composition at different positions of hydrogen and non-hydrogen bonded AAA turns. The presence or absence of Pro at i+1 position of alpha- and beta-turns has a bearing on whether the turn is hydrogen-bonded or without a hydrogen bond. In the tertiary structure, alpha-turns are more likely to be found in beta-hairpin loops. The residue composition at the beginning of the hydrogen bonded AAA alpha-turn has similarity with type I beta-turn and N-terminal positions of helices, but the last position matches with the C-terminal capping position of helices, suggesting that the existence of a "helix cap signal" at i+4 position prevents alpha-turns from growing into helices. Our results also provide new insights into alpha-helix nucleation and folding. Copyright 2004 Wiley-Liss, Inc.

  17. A capacitive, biocompatible and adhesive electrode for long-term and cap-free monitoring of EEG signals.

    PubMed

    Lee, Seung Min; Kim, Jeong Hun; Byeon, Hang Jin; Choi, Yoon Young; Park, Kwang Suk; Lee, Sang-Hoon

    2013-06-01

    Long-term electroencephalogram (EEG) monitoring broadens EEG applications to various areas, but it requires cap-free recording of EEG signals. Our objective here is to develop a capacitive, small-sized, adhesive and biocompatible electrode for the cap-free and long-term EEG monitoring. We have developed an electrode made of polydimethylsiloxane (PDMS) and adhesive PDMS for EEG monitoring. This electrode can be attached to a hairy scalp and be completely hidden by the hair. We tested its electrical and mechanical (adhesive) properties by measuring voltage gain to frequency and adhesive force using 30 repeat cycles of the attachment and detachment test. Electrode performance on EEG was evaluated by alpha rhythm detection and measuring steady state visually evoked potential and N100 auditory evoked potential. We observed the successful recording of alpha rhythm and evoked signals to diverse stimuli with high signal quality. The biocompatibility of the electrode was verified and a survey found that the electrode was comfortable and convenient to wear. These results indicate that the proposed EEG electrode is suitable and convenient for long term EEG monitoring.

  18. Effect of longitudinal aberration in an ion-optical system on the properties of a focused beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Getmanov, V.N.; Ikryanov, I.M.; Savchenko, O.Ya.

    1994-11-01

    Modelling of the processes involved in the passage of a beam through a system of high-voltage electrodes with allowance made for the thermal and grid spreads of transverse particle velocities constitutes a three-dimensional problem that is difficult to solve with modern computers. In the present work, an analytic method has been developed that reduces this problem to a two-dimensional one. The method corresponds to approximating a marked longitudinal aberration in an ion-optical system (IOS), when the effective emittance of the beam during its high-voltage shaping increases severalfold, this being characteristic of all IOS know thus far. Fully justified in thismore » case is the statement that a unique relationship exists between the coordinates r and z, which respectively characterize the location of the particle on the emitter and the point of intersection of the axis by the particle (or the point of maximum approach of the particle to the axis), and also between r and {alpha} ({alpha}being the angle between the particle trajectory in the focusing region and the axis of the system). This statement leads to a hyperbolic law of increase in current density in the central portion of the focused beam and thus confirms the validity of this law. The calculations were compared with experimental data on the focusing of a 0.4-MeV proton beam with a current of 20-75 mA and a diameter of 2-5 mm in the crossover under conditions in which the effective emittance of the beam, as a result of aberrations during its high-voltage shaping, increased by a factor of 3 or more (in kilovolts), and the calculated trajectories for 20 of 40 mm at the emitter are shown, where the markers D8 and D9 denote the positions of multiwire beam profile sensors.« less

  19. Optical properties of thermal control coating contaminated by MMH/N2O4 5-pound thruster in a vacuum environment with solar simulation

    NASA Technical Reports Server (NTRS)

    Sommers, R. D.; Raquet, C. A.; Cassidy, J. F.

    1972-01-01

    Cat-a-lac Black, and S13G thermal control coatings were exposed to the exhaust of a thruster in a simulated space environment. Vacuum was maintained at less than 10 to the minus 5th power torr during thruster firing in the liquid helium cooled facility. The thruster was fired in a 50-millisecond pulse mode and the accumulated firing time was 224 seconds. Solar absorptance (alpha sub s) and thermal emittance (sigma) of the coatings were measured in-situ at intervals of 300 pulses. A calorimetric technique was used to measure alpha sub s and sigma. The tests, technique, and test results are presented. The Cat-a-lac Black coatings showed no change in alpha sub s or sigma. The S13G showed up to 25 percent increase in alpha sub s but no change in sigma.

  20. A survey on uncertainty in bioassay measurements carried out within the OMINEX project.

    PubMed

    Hurtgen, C; Cossonnet, C

    2003-01-01

    One of the topics covered by the OMINEX (Optimisation of Monitoring for Internal Exposure) project was to look at the bioassay measurements performed in the European laboratories. Questionnaires on bioassay measurements by alpha spectrometry or inductively coupled plasma-mass spectrometry (ICP-MS) were sent to European laboratories. The main objective was to collect information on analytical procedures and on the uncertainties associated with bioassay results. Alpha spectrometry is the technique most often used for the determination of alpha emitters, such as actinides in biological samples. ICP-MS is not used much as yet for routine measurements of actinides in biological samples, but is very sensitive for measurements of long-lived radionuclides. The different parameters influencing the uncertainties on the results and the minimum detectable amount have been investigated. Optimum conditions for achieving low result uncertainties and high sensitivity are given for alpha spectrometry and ICP-MS.

  1. Cryopyrin-associated periodic syndromes: development of a patient-reported outcomes instrument to assess the pattern and severity of clinical disease activity.

    PubMed

    Hoffman, Hal M; Wolfe, Frederick; Belomestnov, Pavel; Mellis, Scott J

    2008-09-01

    Development of an instrument for characterization of symptom patterns and severity in patients with cryopyrin-associated periodic syndromes (CAPS). Two generations of daily health assessment forms (DHAFs) were evaluated in this study. The first-generation DHAF queried 11 symptoms. Analyses of results obtained with that instrument identified five symptoms included in a revised second-generation DHAF that was tested for internal consistency and test-retest reliability. This DHAF was also assessed during the initial portion of a phase 3 clinical study of CAPS treatment. Forty-eight CAPS patients provided data for the first-generation DHAFs. Five symptoms (rash, fever, joint pain, eye redness/pain, and fatigue) were included in the revised second-generation DHAF. Symptom severity was highly variable during all study phases with as many as 89% of patients reporting at least one symptom flare, and percentages of days with flares reaching 58% during evaluation of the second-generation instrument. Mean composite key symptom scores (KSSs) computed during evaluation of the second-generation DHAF correlated well with Physician's Global Assessment of Disease Activity (r=0.91, p<0.0001) and patient reports of limitations of daily activities (r=0.68, p<0.0001). Test-retest reliability and Cronbach's alpha's were high (0.93 and 0.94, respectively) for the second-generation DHAF. Further evaluation of this DHAF during a baseline period and placebo treatment in a phase 3 clinical study of CAPS patients indicated strong correlations between baseline KSS and Physician's Global Assessment of Disease Activity. Cronbach's alpha's at baseline and test-retest reliability were also high. Potentially important study limitations include small sample size, the lack of a standard tool for CAPS symptom assessment against which to validate the DHAF, and no assessment of the instrument's responsivity to CAPS therapy. The DHAF is a new instrument that may be useful for capturing symptom patterns and severity in CAPS patients and monitoring responses to therapies for these conditions.

  2. The measurement of alpha particle emissions from semiconductor memory materials

    NASA Astrophysics Data System (ADS)

    Bouldin, D. P.

    1981-07-01

    With the increasing concern for the affects of alpha particles on the reliability of semiconductor memories, an interest has arisen in characterizing semiconductor manufacturing materials for extremely low-level alpha-emitting contaminants. It is shown that four elements are of primary concern: uranium, thorium, radium, and polonium. Measurement of contamination levels are given relevance by first correlating them with alpha flux emission levels and then corre1ating these flux values with device soft error rates. Measurement techniques involve either measurements of elemental concentrations-applicable to only uranium and thorium - or direct measurements of alpha emission fluxes. Alpha fluxes are most usefully measured by means of ZnS scintillation counting, practical details of which are discussed. Materials measurements are reported for ceramics, solder, silicon, quartz, and various metals and organic materials. Ceramics and most metals have contamination levels of concern, but the high temperature processing normally used in semiconductor manufacturing and low total amounts reduce problems, at least for metals. Silicon, silicon compounds, and organic materials have been found to have no detectable alpha emitters. Finally, a brief discussion of the calibration of alpha sources for accelerated device testing is given, including practical details on the affects of source/chip separation and alignment variations.

  3. Radiation resistant PIDECα cell using photon intermediate direct energy conversion and a 210Po source.

    PubMed

    Weaver, Charles L; Schott, Robert J; Prelas, Mark A; Wisniewski, Denis A; Rothenberger, Jason B; Lukosi, Eric D; Oh, Kyuhak

    2018-02-01

    Radiation damage is a significant concern with both alphavoltaic and betavoltaic cells because their performance degrades, especially with high-energy - (>200keV) beta and alpha particles. Indirect excitation methods, such as the Photon Intermediate Direct Energy Conversion (PIDEC) framework, can protect the transducer from radiation. A nuclear battery using a 90 Sr beta source was constructed by the author's research group, which demonstrated the radiation resistance of a PIDEC cell driven by beta particles (PIDECβ cell). Use of alpha sources to drive nuclear batteries would appear to be much more attractive than beta sources due to higher potential power density. However, they are also subject to higher rates of radiation damage. This paper describes the successful incorporation of alpha particles into the PIDEC framework using the alpha emitter 210 Po to form a PIDECα cell. The PIDECα cell transducer was exposed to alpha particles for over one year without experiencing adverse effects from radiation damage. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Preparation of alpha-cyclodextrin-terminated polyrotaxane consisting of beta-cyclodextrins and pluronic as a building block of a biodegradable network.

    PubMed

    Ooya, Tooru; Ito, Akihiro; Yui, Nobuhiko

    2005-05-23

    A beta-CD-based biodegradable polyrotaxane was prepared by capping both terminals of polypseudorotaxane consisting of hydrazide-terminated PEG-block-PPG-block-PEG (Pluronic P-105) and beta-CD-succinates with mono-aldehyde alpha-CDs. By decreasing pH, the fluorescent intensity of TNS was increased with time, indicating cleavage of the terminal hydrazone bonds followed by beta-CD-succinate release. The terminal alpha-CD moieties of the polyrotaxane are useful for self-assembled formation with some guest molecules. [Diagram: see text

  5. Structural enhancement of ZnO on SiO2 for photonic applications

    NASA Astrophysics Data System (ADS)

    Ruth, Marcel; Meier, Cedrik

    2013-07-01

    Multi-layer thin films are often the basis of photonic devices. Zinc oxide (ZnO) with its excellent optoelectronic properties can serve as a high quality emitter in structures like microdisks or photonic crystals. Here, we present a detailed study on the enhancement of the structural properties of low-temperature MBE grown ZnO on silica (SiO2). By thermal annealing a grain coalescence of the initially polycrystalline layer leads to an enhancement of the electronic structure, indicated by a blue shift of the photoluminescence (PL) signal maximum. Oxygen atmosphere during the annealing process prevents the creation of intrinsic defects by out-diffusion. Pre-annealing deposited SiO2 capping layers instead obstruct the recrystallization and lead to less intense emission. While thin capping layers partially detach from the ZnO film at high temperatures and cause higher surface roughness and the weakest emission, thicker layers remain smoother and exhibit a significantly stronger photoluminescence.

  6. A New Population of High-z, Dusty Lyman-alpha Emitters and Blobs Discovered by WISE: Feedback Caught in the Act?

    NASA Technical Reports Server (NTRS)

    Bridge, Carrie R.; Blain, Andrew; Borys, Colin J. K.; Petty, Sara; Benford, Dominic; Eisenhardt, Peter; Farrah, Duncan; Griffith, Roger, L.; Jarrett, Tom; Lonsdale, Carol; hide

    2013-01-01

    By combining data from the NASA Wide-field Infrared Survey Explorer (WISE) mission with optical spectroscopy from the W. M. Keck telescope, we discover a mid-IR color criterion that yields a 78% success rate in identifying rare, typically radio-quiet, 1.6 approx. < z approx. < 4.6 dusty Ly-alpha emitters (LAEs). Of these, at least 37% have emission extended on scales of 30-100 kpc and are considered Ly-alpha "blobs" (LABs). The objects have a surface density of only approx.. 0.1 deg(exp -2), making them rare enough that they have been largely missed in deep, small area surveys. We measured spectroscopic redshifts for 92 of these galaxies, and find that the LAEs (LABs) have a median redshift of 2.3 (2.5). The WISE photometry coupled with data from Herschel (Herschel is an ESA space observatory with science instruments provided by European-led Principal Investigator consortia and with important participation from NASA) reveals that these galaxies are in the Hyper Luminous IR galaxy regime (L(sub IR) approx. > 10(exp 13)-10(exp 14) Solar L) and have warm colors. They are typically more luminous and warmer than other dusty, z approx.. 2 populations such as submillimeter-selected galaxies and dust-obscured galaxies. These traits are commonly associated with the dust being illuminated by intense active galactic nucleus activity. We hypothesize that the combination of spatially extended Ly-alpha, large amounts of warm IR-luminous dust, and rarity (implying a short-lived phase) can be explained if the galaxies are undergoing brief, intense "feedback" transforming them from an extreme dusty starburst/QSO into a mature galaxy.

  7. Solubilization of cyclohexane in aqueous solutions of sodium. cap alpha. -alkyl alkanoates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sagitani, H.; Suzuki, T.; Nagai, M.

    1982-01-01

    The effect of branched alkyl chain length and the position of the COONa group on the solubilizing power of n-alkane sodium carboxylates was studied. The lipophilic property and the amount of solubilized cyclohexane increased with the branched chain length of branched soaps, and with the change of the position of the -COONa group from 3 to 7 in the alkyl chain of pentadecane -3, -5, and -7 sodium carboxylates. Alpha-branched soaps having proper branched alkyl chains were better solubilizers for cyclohexane than straight chain compounds. The amount of cyclohexane solublized by C/sub 10/ H/sub 21/ CH(C/sub 6/H/sub 13/) COONa wasmore » about three times greater than the amount solubilized by C/sub 17/ H/sub 35/ COONa. There was a marked increase in the solubilization of cyclohexane replacing ..cap alpha..-branched fatty acid soaps with optimum amount of cosurfactants such as C/sub 8/H/sub 17/ (OCH/sub 2/CH/sub 2/)/sub 2/OH. Namely, solubilization increased markedly at the optimum hydrophile-lipophile balance of mixed surfactant. 21 references.« less

  8. Inhibition of radioemesis by disruption of catecholamines in dogs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luthra, Y.K.; Mattsson, J.L.; Yochmowitz, M.G.

    1981-03-01

    Dogs were treated 30 min to 1 h before x irradiation with ..cap alpha..-methyl-p-tyrosine or 6-hydroxydopamine. A third group of dogs was given a known antiradioemetic drug, haloperidol to verify the sensitivity of the procedure. Irradiated but untreated controls were also used. Light methoxyflurane anesthesia was used for restraint during the exposure. Exposure dose was 800 rad kerma delivered at 50 rad/min to a 10 x 10-cm area covering the abdominal area from xiphoid to pubis. Haloperidol and 6-hydroxydopamine significantly reduced the number of emetic episodes and delayed the onset time to the first episode, ..cap alpha..-Methyl-p-tyrosine caused no significantmore » changes. The effectiveness of 6-hydroxydopamine indicates that catecholaminergic neurons are involved in radioemesis, whereas haloperidol and phenothiazine-derivative tranquilizers inhibit radiomesis by blocking catecholamine receptor neurons.« less

  9. ADP-ribosylation of membrane components by pertussis and cholera toxin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ribeiro-Neto, F.A.P.; Mattera, F.; Hildebrandt, J.D.

    1985-01-01

    Pertussis and cholera toxins are important tools to investigate functional and structural aspects of the stimulatory (N/sub s/) and inhibitory (N/sub i/) regulatory components of adenylyl cyclase. Cholera toxin acts on N/sub s/ by ADP-ribosylating its ..cap alpha../sub s/ subunit; pertussis toxin acts on N/sub i/ by ADP-ribosylating its ..cap alpha..; subunit. By using (/sup 32/P)NAD/sup +/ and determining the transfer of its (/sup 32/P)ADP-ribose moiety to membrane components, it is possible to obtain information on N/sub s/ and N/sub i/. A set of protocols is presented that can be used to study simultaneously and comparatively the susceptibility of N/submore » s/ and N/sub i/ to be ADP-ribosylated by cholera and pertussis toxin.« less

  10. /sup 45/Ca efflux for myometrial cells: comparison of the effects of prostaglandin F/sub 2/. cap alpha. (PGF/sub 2/), oxytocin (OT) and arachidonate (A)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Katona, G.; Molnar, M.; Toth, M.

    1986-03-01

    The aim of this study was to measure PGF/sub 2..cap alpha../-induced Ca/sup 2 +/ release from uterine cells and to compare this to the actions of OT and A. Smooth muscle cells isolated from the uterus (shell gland) of laying hens were cultured for 7 days in M199 plus 10% fetal calf serum. The cells were treated with digitonin (20..mu..M) and preloaded with /sup 45/Ca for 40 min. Addition of PGF/sub 2..cap alpha../ caused a biphasic /sup 45/Ca-efflux. There was a small but significant /sup 45/Ca-release within 30 sec (rapid phase) followed by a larger one within 7 min (slowmore » phase). In comparison, both OT and A stimulated /sup 45/Ca efflux during a single, slow phase. The maximal effect of A was observed at < 7 min, whereas that of OT was slower, peaking after 7 min. Mepacrin, an inhibitor of A release, attenuated the action of OT without having any effect on A promoted /sup 45/Ca-efflux. Indomethacin, an inhibitor of PG synthase, failed to suppress the Ca-releasing effect of A suggesting the A itself or a lipoxygenase product may have been responsible for the observed effects. Moreover, these results provide suggestive evidence that A release is an important step in the action of various uterotonic agents converging on the mobilization of intracellular Ca.« less

  11. Discharging Static Electricity From Inside A Glass Tube

    NASA Technical Reports Server (NTRS)

    Ellsbury, Walter L.

    1994-01-01

    Device that contains emitter of alpha particles discharges static electricity from inside wall of glass tube of volumetric-flow calibrator. Includes cylinder that has wall thickness of 1/16 in., diameter about 1/2 in. smaller than inside diameter of tube, and height that extends about 1/2 in. above piston that moves along tube and is part of calibrator.

  12. Mixture quantification using PLS in plastic scintillation measurements.

    PubMed

    Bagán, H; Tarancón, A; Rauret, G; García, J F

    2011-06-01

    This article reports the capability of plastic scintillation (PS) combined with multivariate calibration (Partial least squares; PLS) to detect and quantify alpha and beta emitters in mixtures. While several attempts have been made with this purpose in mind using liquid scintillation (LS), no attempt was done using PS that has the great advantage of not producing mixed waste after the measurements are performed. Following this objective, ternary mixtures of alpha and beta emitters ((241)Am, (137)Cs and (90)Sr/(90)Y) have been quantified. Procedure optimisation has evaluated the use of the net spectra or the sample spectra, the inclusion of different spectra obtained at different values of the Pulse Shape Analysis parameter and the application of the PLS1 or PLS2 algorithms. The conclusions show that the use of PS+PLS2 applied to the sample spectra, without the use of any pulse shape discrimination, allows quantification of the activities with relative errors less than 10% in most of the cases. This procedure not only allows quantification of mixtures but also reduces measurement time (no blanks are required) and the application of this procedure does not require detectors that include the pulse shape analysis parameter. Copyright © 2011 Elsevier Ltd. All rights reserved.

  13. Measurement of the Solar Absorptance and Thermal Emittance of Lunar Simulants

    NASA Technical Reports Server (NTRS)

    Gaier, James R.; Street, Kenneth W.; Gustafson, Robert J.

    2010-01-01

    The first comparative study of the reflectance spectra of lunar simulants is presented. All of the simulants except one had a wavelength-dependent reflectivity, rho(lambda), near 0.10 over the wavelength range of 8 to 25 microns, so they are highly emitting at room temperature and lower. The 300 K emittance, epsilon, of all the lunar simulants except one ranged from 0.884 to 0.906. The 300 K epsilon of JSC Mars-1 simulant was 0.927. There was considerably more variation in the lunar simulant reflectance in the solar spectral range (250 to 2500 nm) than in the thermal infrared. Larger particle size simulants reflected much less than those with smaller particle size. As expected, the lunar highlands simulants were more reflective in this wavelength range than the lunar mare simulants. The alpha of the simulants ranged from 0.413 to 0.817 for those with smaller particles and 0.669 to 0.906 for large particles. Although spectral differences were observed, the total integrated alpha for the simulants appears to be similar to that of lunar soils (0.65 to 0.88). These data are now available to be used in modeling the effects of dust on thermal control surfaces.

  14. Congenital Muscle Disease Study of Patient and Family Reported Medical Information

    ClinicalTrials.gov

    2017-05-05

    Congenital Muscular Dystrophy (Including Unspecified/Undiagnosed); Dystroglycanopathy; Congenital Fiber Type Disproportion; Rigid Spine Muscular Dystrophy; Congenital Myopathy (Including Unspecified/Undiagnosed); Collagen VI CMD (Ullrich CMD, Intermediate, Bethlem Myopathy); Laminin Alpha 2 Related Congenital Muscular Dystrophy; LAMA2-CMD/Merosin Deficient/MDC1A; Walker-Warburg Syndrome; Muscle-Eye-Brain Disease; Fukuyama/Fukutin Related Muscular Dystrophy; Integrin Alpha 7 Deficiency; Integrin Alpha 9 Deficiency; LMNA-CMD/Lamin A/C/Laminopathy; SEPN1-Related Myopathy; Bethlem Myopathy; Actin Aggregation Myopathy; Cap Disease; Central Core Disease; Centronuclear Myopathy; Core Rod Myopathy; Hyaline Body Myopathy; Multiminicore Myopathy; Myotubular Myopathy; Nemaline Myopathy; Tubular Aggregate Myopathy; Zebra Body Myopathy; Reducing Body Myopathy; Spheroid Body Myopathy; LGMD1B (LMNA); LGMD1E (DES); LGMD2G (TCAP); LGMD2H (TRIM32); LGMD2I (FKRP); LGMD2J (TTN); LGMD2K (POMT1); LGMD2M (FKTN); LGMD2N (POMT2); LGMD2O (POMGnT1); LGMD2P (DAG1); LGMD2Q (PLEC1); LGMD2R (DES); LGMD2S (TRAPPC11); LGMD2T (GMPPB); LGMD2U (ISPD); LGMD2V (GAA); Ullrich Congenital Muscular Dystrophy; Titinopathy; Choline Kinase B Receptor; Emery-Dreifuss Muscular Dystrophy; RYR1 Related Myopathy; SYNE1/Nesprin Related Muscular Dystrophy; Telethonin Related Muscular Dystrophy (TCAP/Titin-Cap); Congenital Myasthenic Syndrome; Escobar Syndrome; Myofibrillar Myopathy; Malignant Hyperthermia; Alpha-Dystroglycan Related Muscular Dystrophy (DAG1, DPM1, DPM2, DPM3, FKRP, FKTN); Alpha-Dystroglycan Related Muscular Dystrophy (GAA, ISPD, LARGE, POMT1, POMT2, POMGnT1); Alpha-Dystroglycan Related Muscular Dystrophy (Unspecified/Undiagnosed/Other)

  15. The relationship between red meat allergy and sensitization to gelatin and galactose-alpha-1,3-galactose

    PubMed Central

    Mullins, Raymond James; James, Hayley; Platts-Mills, Thomas A.E.; Commins, Scott

    2012-01-01

    Background We have observed patients clinically allergic to red meat and meat-derived gelatin. Objective We describe a prospective evaluation of the clinical significance of gelatin sensitization, the predictive value of a positive test and an examination of the relationship between allergic reactions to red meat and sensitization to gelatin and alpha-Gal. Methods Adult patients evaluated 1997-2011 for suspected allergy/anaphylaxis to medication, insect venom or food were skin tested with gelatin colloid. In vitro (ImmunoCap) testing was undertaken where possible. Results Positive gelatin tests were observed in 40/1335 individuals; 30/40 patients with red meat allergy (12 also clinically allergic to gelatin); 2/2 with gelatin colloid anaphylaxis; 4/172 with idiopathic anaphylaxis (all responded to intravenous gelatin challenge of 0.02 to 0.4g); 4/368 with drug allergy. Testing was negative in all patients with venom allergy (n=241), non-meat food allergy (n=222), and miscellaneous disorders (n=290). ImmunoCap was positive to alpha-Gal in 20/24 meat allergics and in 20/22 with positive gelatin skin tests. The results of gelatin skin testing and anti-alpha-Gal IgE were strongly correlated (r=0.46; P<0.01). Alpha-Gal was detected in bovine gelatin colloids at concentrations of ~ 0.44 to 0.52ug/gm gelatin by inhibition radioimmunoassay. Conclusion Most patients allergic to red meat were sensitized to gelatin and a subset was clinically allergic to both. The detection of alpha-Gal in gelatin and correlation between the results of alpha-Gal and gelatin testing raises the possibility that alpha-Gal IgE may be the target of reactivity to gelatin. The pathogenic relationship between tick bites and sensitization to red meat, alpha-Gal and gelatin (with or without clinical reactivity) remains uncertain. PMID:22480538

  16. Radiobiological long-term accumulation of environmental alpha radioactivity in extracted human teeth and animal bones in Malaysia.

    PubMed

    Almayahi, B A; Tajuddin, A A; Jaafar, M S

    2014-03-01

    In this study, the radiobiological analysis of natural alpha emitters in extracted human teeth and animal bones from Malaysia was estimated. The microdistributions of alpha particles in tooth and bone samples were measured using CR-39 alpha-particle track detectors. The lowest and highest alpha emission rates in teeth in the Kedah and Perak states were 0.0080 ± 0.0005 mBq cm(-2) and 0.061 ± 0.008 mBq cm(-2), whereas those of bones in the Perlis and Kedah states were 0.0140 ± 0.0001 mBq cm(-2) and 0.7700 ± 0.0282 mBq cm(-2), respectively. The average alpha emission rate in male teeth was 0.0209 ± 0.0008 mBq cm(-2), whereas that of female teeth was 0.0199 ± 0.0010 mBq cm(-2). The alpha emission rate in teeth is higher in smokers (0.0228 ± 0.0008 mBq cm(-2)) than in non-smokers (0.0179 ± 0.0008 mBq cm(-2)). Such difference was found statistically significant (p < 0.01). Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Design, construction and measurements of an alpha magnet as a solution for compact bunch compressor for the electron beam from Thermionic RF Gun

    NASA Astrophysics Data System (ADS)

    Rajabi, A.; Jazini, J.; Fathi, M.; Sharifian, M.; Shokri, B.

    2018-03-01

    The beam produced by a thermionic RF gun has wide energy spread that makes it unsuitable for direct usage in photon sources. Here in the present work, we optimize the extracted beam from a thermionic RF gun by a compact economical bunch compressor. A compact magnetic bunch compressor (Alpha magnet) is designed and constructed. A comparison between simulation results and experimental measurements shows acceptable conformity. The beam dynamics simulation results show a reduction of the energy spread as well as a compression of length less than 1 ps with 2.3 mm-mrad emittance.

  18. Systems and methods for neutron detection using scintillator nano-materials

    DOEpatents

    Letant, Sonia Edith; Wang, Tzu-Fang

    2016-03-08

    In one embodiment, a neutron detector includes a three dimensional matrix, having nanocomposite materials and a substantially transparent film material for suspending the nanocomposite materials, a detector coupled to the three dimensional matrix adapted for detecting a change in the nanocomposite materials, and an analyzer coupled to the detector adapted for analyzing the change detected by the detector. In another embodiment, a method for detecting neutrons includes receiving radiation from a source, converting neutrons in the radiation into alpha particles using converter material, converting the alpha particles into photons using quantum dot emitters, detecting the photons, and analyzing the photons to determine neutrons in the radiation.

  19. Crystal structure of Bacillus anthracis transpeptidase enzyme CapD.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, R.; Richter, S.; Zhang, R.

    2009-09-04

    Bacillus anthracis elaborates a poly-{gamma}-d-glutamic acid capsule that protects bacilli from phagocytic killing during infection. The enzyme CapD generates amide bonds with peptidoglycan cross-bridges to anchor capsular material within the cell wall envelope of B. anthracis. The capsular biosynthetic pathway is essential for virulence during anthrax infections and can be targeted for anti-infective inhibition with small molecules. Here, we present the crystal structures of the {gamma}-glutamyltranspeptidase CapD with and without {alpha}-l-Glu-l-Glu dipeptide, a non-hydrolyzable analog of poly-{gamma}-d-glutamic acid, in the active site. Purified CapD displays transpeptidation activity in vitro, and its structure reveals an active site broadly accessible for poly-{gamma}-glutamatemore » binding and processing. Using structural and biochemical information, we derive a mechanistic model for CapD catalysis whereby Pro{sup 427}, Gly{sup 428}, and Gly{sup 429} activate the catalytic residue of the enzyme, Thr{sup 352}, and stabilize an oxyanion hole via main chain amide hydrogen bonds.« less

  20. Effects of growth retardants and fumigations with ozone and sulfur dioxide on growth and flowering of Euphorbia pulcherrima Willd

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cathey, H.M.; Heggestad, H.E.

    1973-01-01

    Eight cultivars of poinsettia, Euphorbia pulcherrima Willd., were evaluated for sensitivity to ..cap alpha..-cyclopropyl-..cap alpha.. (4-methoxyphenyl)-5-pyrimidine methanol (ancymidol) and protection from ozone and sulfur dioxide injury afforded by applications of ancymidol and (2-chloroethyl) trimethyl ammonium chloride (chlormequat). Foliar sprays of ancymidol were at least 80 to 500 times and the soil drench 1000 times more active than chlormequat in retarding stem elongation. The diam of the bracts was reduced, but branching increased more on plants treated with ancymidol than on untreated plants. The cv. Annette Hegg (AH) was more sensitive to ozone fumigations than was Eckespoint C-1' (C-1). Sulfur dioxidemore » also caused more injury to AH than to C-1. Ancymidol and chlormequat reduced visible injury induced by ozone and sulfur dioxide.« less

  1. Copernicus observational searches for OH and H/sub 2/O in diffuse clouds

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, W.H.; Snow, T.P. Jr.

    1979-03-01

    An intensive search for OH and H/sub 2/O in the directions of sigma Sco, ..cap alpha.. Cam, and omicron Per was undertaken with the Copernicus satellite. Multiple scans were carried out over the wavelength region for the expected absorption features due to the OH D--X and H/sub 2/O C--X transitions. The feature due to OH was possibly detected toward sigma Sco, and only an upper limit can be given toward ..cap alpha.. Cam. H/sub 2/O was not detected in any of the stars at the signal level accumulated. The OH abundance toward sigma Sco and the respective lower limits formore » the OH/H/sub 2/O ratios are discussed with regard to the extant models for the steady-state abundances of OH and H/sub 2/O, and shown not to be inconsistent with ion-molecule schemes.« less

  2. Expected Backgrounds of the BetaCage, an Ultra-sensitive Screener for Surface Contamination

    NASA Astrophysics Data System (ADS)

    Wang, Boqian; Bunker, Raymond; Schnee, Richard; Bowles, Michael; Kos, Marek; Ahmed, Zeeshan; Golwala, Sunil; Nelson, Robert; Grant, Darren

    2013-04-01

    Material screening for low-energy betas and alphas is necessary for rare-event-search experiments, such as dark matter and neutrinoless double-beta decay searches where surface radiocontamination has become a significant background. The BetaCage, a gaseous neon time-projection chamber, has been proposed as a screener for emitters of low-energy betas and alphas to which existing screening facilities are insufficiently sensitive. The expected sensitivity is 0.1 betas / (keV m^2 day) and 0.1 alphas / (m^2 day). Expected backgrounds are dominated by Compton scattering of external photons in the sample to be screened; radioassays and simulations indicate backgrounds from detector materials and radon daughters should be subdominant. We will report on details of the background simulations and the detector design that allows discrimination to reach these sensitivity levels.

  3. Detection of 210Po on filter papers 16 years after use for the collection of short-lived radon progeny in a room.

    PubMed

    Abu-Jarad, F; Fazal-ur-Rehman

    2003-01-01

    Radon gas was allowed to accumulate in its radium source and then injected into a 36 m(3) test room, resulting in an initial radon concentration of 15 kBq m(-3). Filter papers were used to collect the short-lived radon progeny and thus to measure the Potential Alpha Energy Concentration (PAEC) in-situ in the year 1984 at different times and conditions according to the experimental design. The radon progeny collected on the filter papers were studied as a function of aerosol particle concentration ranging from 10(2)-10(5) particles cm(-3) in three different experiments. The highest aerosol particle concentration was generated by indoor cigarette smoking. Those filters were stored after the experiment, and were used after 16 years to study the activity of the radon long-lived alpha emitter progeny, (210)Po (T(1/2)=138 days). This isotope is separated from the short-lived progeny by (210)Pb beta emitter with 22.3 years half-life. After 16 years' storage of these filters, each filter paper was sandwiched and wrapped between two CR-39 nuclear track detectors, to put the detectors in contact with the surfaces of different filters, for 337 days. Correlation between the PAEC measured using filter papers in the year 1984 and the activity of long-lived alpha emitter (210)Po on the same filter papers measured in the year 2000 were studied. The results of the (210)Po activity showed a very good correlation of 0.92 with the PAEC 16 years ago. The results also depict that the PAEC and (210)Po activity in indoor air increased with the increase of aerosol particle concentration, which shows the attachment of short-lived radon progeny with the aerosol particles. The experiment proves that indoor cigarette smoking is a major source of aerosol particles carrying radon progeny and, thus, indoor cigarette smoking is an additional source of internal radiation hazard to the occupants whether smoker or non-smoker.

  4. An MR-compliant phased-array HIFU transducer with augmented steering range, dedicated to abdominal thermotherapy

    NASA Astrophysics Data System (ADS)

    Auboiroux, Vincent; Dumont, Erik; Petrusca, Lorena; Viallon, Magalie; Salomir, Rares

    2011-06-01

    A novel architecture for a phased-array high intensity focused ultrasound (HIFU) device was investigated, aiming to increase the capabilities of electronic steering without reducing the size of the elementary emitters. The principal medical application expected to benefit from these developments is the time-effective sonication of large tumours in moving organs. The underlying principle consists of dividing the full array of transducers into multiple sub-arrays of different resonance frequencies, with the reorientation of these individual emitters, such that each sub-array can focus within a given spatial zone. To enable magnetic resonance (MR) compatibility of the device and the number of output channels from the RF generator to be halved, a passive spectral multiplexing technique was used, consisting of parallel wiring of frequency-shifted paired piezoceramic emitters with intrinsic narrow-band response. Two families of 64 emitters (circular, 5 mm diameter) were mounted, with optimum efficiency at 0.96 and 1.03 MHz, respectively. Two different prototypes of the HIFU device were built and tested, each incorporating the same two families of emitters, but differing in the shape of the rapid prototyping plastic support that accommodated the transducers (spherical cap with radius of curvature/aperture of 130 mm/150 mm and, respectively, 80 mm/110 mm). Acoustic measurements, MR-acoustic radiation force imaging (ex vivo) and MR-thermometry (ex vivo and in vivo) were used for the characterization of the prototypes. Experimental results demonstrated an augmentation of the steering range by 80% along one preferentially chosen axis, compared to a classic spherical array of the same total number of elements. The electric power density provided to the piezoceramic transducers exceeded 50 W cm-2 CW, without circulation of coolant water. Another important advantage of the current approach is the versatility of reshaping the array at low cost.

  5. An MR-compliant phased-array HIFU transducer with augmented steering range, dedicated to abdominal thermotherapy.

    PubMed

    Auboiroux, Vincent; Dumont, Erik; Petrusca, Lorena; Viallon, Magalie; Salomir, Rares

    2011-06-21

    A novel architecture for a phased-array high intensity focused ultrasound (HIFU) device was investigated, aiming to increase the capabilities of electronic steering without reducing the size of the elementary emitters. The principal medical application expected to benefit from these developments is the time-effective sonication of large tumours in moving organs. The underlying principle consists of dividing the full array of transducers into multiple sub-arrays of different resonance frequencies, with the reorientation of these individual emitters, such that each sub-array can focus within a given spatial zone. To enable magnetic resonance (MR) compatibility of the device and the number of output channels from the RF generator to be halved, a passive spectral multiplexing technique was used, consisting of parallel wiring of frequency-shifted paired piezoceramic emitters with intrinsic narrow-band response. Two families of 64 emitters (circular, 5 mm diameter) were mounted, with optimum efficiency at 0.96 and 1.03 MHz, respectively. Two different prototypes of the HIFU device were built and tested, each incorporating the same two families of emitters, but differing in the shape of the rapid prototyping plastic support that accommodated the transducers (spherical cap with radius of curvature/aperture of 130 mm/150 mm and, respectively, 80 mm/110 mm). Acoustic measurements, MR-acoustic radiation force imaging (ex vivo) and MR-thermometry (ex vivo and in vivo) were used for the characterization of the prototypes. Experimental results demonstrated an augmentation of the steering range by 80% along one preferentially chosen axis, compared to a classic spherical array of the same total number of elements. The electric power density provided to the piezoceramic transducers exceeded 50 W cm(-2) CW, without circulation of coolant water. Another important advantage of the current approach is the versatility of reshaping the array at low cost.

  6. Tumor initiating activities of various derivatives of benz(a)anthracene and 7, 12-dimethyl-benz(a)anthracene in mouse skin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Slaga, T.J.; Gleason, G.L.; DiGiovanni, J.

    Current information indicates that polycyclic aromatic hydrocarbons (PAH) exert their toxic, mutagenic, and carcinogenic activities after they have been metabolically activated by target cells to reactive epoxides. The results obtained from IN VIVO and IN VITRO binding, mutagenicity, metabolism, and carcinogenicity studies have led to the conclusion that BP-7, 8-diol is a proximate carcinogenic metabolite of BP, and the BP-diol-epoxide is an ultimate carcinogenic metabolite of BP. Recent results concerning the strong carcinogenicity of BP-7..beta.., 8..cap alpha..-diol-9..cap alpha..,10..cap alpha..-epoxide in newborn mice and in mouse skin strongly indicate that it is the ultimate carcinogenic metabolite of BP. Since diol-epoxides maymore » be responsible for the carcinogenicity of PAH other than BP, diols and diol-epoxides as well as other derivatives of PAH were tested for skin tumor-initiation in a two-stage system of tumorigenesis. In addition, since activation of methylated PAH may involve the side-chain methyl group, the skin tumor-initiating activity of various side-chain derivatives of methylated PA were determined. In this report, the skin tumor initiation of various derivatives of a nonmethylated PAH, BA as well as a methylated PAH, DMBA are compared. The data suggest that bay region diol-epoxides may be important in BA and DMBA carcinogenicity in mice which is supportive of the theory proposed by Jerina and co-workers which predicts that diol-epoxides in the bay region are the major determinants of PAH carcinogenicity.« less

  7. Assignments of /sup 1/H nuclear magnetic resonances of the cystyl, asparaginyl, and aromatic residues of arginine vasopressin in D/sub 2/O. A comparison with lysine vasopressin and oxytocin in terms of solution conformation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wyssbrod, H.R.; Fischman, A.J.; Live, D.H.

    1979-07-18

    The resonances of the C/sup ..cap alpha../ and C/sup ..beta../ protons of the cystyl, asparaginyl, and aromatic residues of (8-arginine)vasopressin (AVP) in D/sub 2/O at pD 3.8 and 20/sup 0/C were assigned in a rigorous manner by the use of isotopic isomers of AVP that contain specific replacements of protons by deuterons and by comparison of /sup 1/H NMR characteristics of AVP to those of (8-lysine)vasopressin (LVP) and oxytocin (OT). Although there is extensive overlap of resonances of C/sup ..beta../ protons even at 360 MHz, all of the chemical shifts of these protons and most of the couplings between themmore » and their vicinal C/sup ..cap alpha../ protons could be determined, at least to a first approximation. It was concluded that the cyclic moieties (residues 1-6) of AVP, LVP, and OT possess essentially the same overall backbone conformation, and that the side-chain conformation - or rotamer populations - about the C/sup ..cap alpha../-C/sup ..beta../ bonds of the cystyl residue (positions 1 and 6), the tyrosyl residue (position 2), and the asparaginyl residue (position 5) are similar. This study indicates that selective replacements of C/sup ..beta../ protons by deuterons are necessary to improve the accuracy of coupling constants extracted from 360-MHz spectra of a AVP for use in conformational analysis.« less

  8. Testing the stand-alone microbeam at Columbia University.

    PubMed

    Garty, G; Ross, G J; Bigelow, A W; Randers-Pehrson, G; Brenner, D J

    2006-01-01

    The stand-alone microbeam at Columbia University presents a novel approach to biological microbeam irradiation studies. Foregoing a conventional accelerator as a source of energetic ions, a small, high-specific-activity, alpha emitter is used. Alpha particles emitted from this source are focused using a compound magnetic lens consisting of 24 permanent magnets arranged in two quadrupole triplets. Using a 'home made' 6.5 mCi polonium source, a 1 alpha particle s(-1), 10 microm diameter microbeam can, in principle, be realised. As the alpha source energy is constant, once the microbeam has been set up, no further adjustments are necessary apart from a periodic replacement of the source. The use of permanent magnets eliminates the need for bulky power supplies and cooling systems required by other types of ion lenses and greatly simplifies operation. It also makes the microbeam simple and cheap enough to be realised in any large lab. The Microbeam design as well as first tests of its performance, using an accelerator-based beam are presented here.

  9. Radiation-induced biologic bystander effect elicited in vitro by targeted radiopharmaceuticals labeled with alpha-, beta-, and auger electron-emitting radionuclides.

    PubMed

    Boyd, Marie; Ross, Susan C; Dorrens, Jennifer; Fullerton, Natasha E; Tan, Ker Wei; Zalutsky, Michael R; Mairs, Robert J

    2006-06-01

    Recent studies have shown that indirect effects of ionizing radiation may contribute significantly to the effectiveness of radiotherapy by sterilizing malignant cells that are not directly hit by the radiation. However, there have been few investigations of the importance of indirect effects in targeted radionuclide treatment. Our purpose was to compare the induction of bystander effects by external beam gamma-radiation with those resultant from exposure to 3 radiohaloanalogs of metaiodobenzylguanidine (MIBG): (131)I-MIBG (low-linear-energy-transfer [LET] beta-emitter), (123)I-MIBG (potentially high-LET Auger electron emitter), and meta-(211)At-astatobenzylguanidine ((211)At-MABG) (high-LET alpha-emitter). Two human tumor cell lines-UVW (glioma) and EJ138 (transitional cell carcinoma of bladder)-were transfected with the noradrenaline transporter (NAT) gene to enable active uptake of MIBG. Medium from cells that accumulated the radiopharmaceuticals or were treated with external beam radiation was transferred to cells that had not been exposed to radioactivity, and clonogenic survival was determined in donor and recipient cultures. Over the dose range 0-9 Gy of external beam radiation of donor cells, 2 Gy caused 30%-40% clonogenic cell kill in recipient cultures. This potency was maintained but not increased by higher dosage. In contrast, no corresponding saturation of bystander cell kill was observed after treatment with a range of activity concentrations of (131)I-MIBG, which resulted in up to 97% death of donor cells. Cellular uptake of (123)I-MIBG and (211)At-MABG induced increasing recipient cell kill up to levels that resulted in direct kill of 35%-70% of clonogens. Thereafter, the administration of higher activity concentrations of these high-LET emitters was inversely related to the kill of recipient cells. Over the range of activity concentrations examined, neither direct nor indirect kill was observed in cultures of cells not expressing the NAT and, thus, incapable of active uptake of MIBG. Potent toxins are generated specifically by cells that concentrate radiohalogenated MIBG. These may be LET dependent and distinct from those elicited by conventional radiotherapy.

  10. Long-term treatment with calcium-alpha-ketoglutarate corrects secondary hyperparathyroidism.

    PubMed

    Zimmermann, E; Wassmer, S; Steudle, V

    1996-01-01

    Calcium-alpha-ketoglutarate (Ca-ket) is known as a highly effective phosphate (P) binder in hemodialysis (HD) patients. In addition, alpha-ketoglutarate has been shown to improve metabolic alterations. We investigated the effect of long-term P-binding therapy with Ca-ket to determine whether P accumulation is the main reason of secondary hyperparathyroidism (HPT) in HD patients or not. Ca-ket was prescribed to 14 HD patients as a soluble preparation in a mean dosage of 4.5 g/day (0.975 g elemental Ca) for a period of 36 months. Serum P continuously dropped from prestudy 2.6 +/- 0.1 (mean +/- SEM) to 1.9 +/- 0.07 mmol/l (p < 0.001), whereas serum Ca increased from 2.2 +/- 0.1 to 2.47 +/- 0.08 mmol/l (p < 0.05). Thus, Ca/P ratio in serum converted significantly from 0.91 +/- 0.02 (prestudy) to 1.28 +/- 0.01 (p < 0.001). Intact parathyroid hormone (iPTH) continuously normalized in all patients from 29 +/- 5 to 8 +/- 2 pmol/l (p < 0.001). The present data show that long-term treatment with Ca-ket normalizes secondary HPT by simultaneously P binding and correcting Ca/P ratio in serum without vitamin D treatment.

  11. Sample preparation for the determination of 241Am in sediments utilizing gamma-spectroscopy.

    PubMed

    Ristic, M; Degetto, S; Ast, T; Cantallupi, C

    2002-01-01

    This paper describes a procedure developed to separate americium-241 from the bulk of a sample by coprecipitation followed by high sensitivity gamma-counting of the concentrate in a well-type detector. It enables the measurement of 241Am at low concentrations, e.g. fallout levels in soils and sediments, or where large sample sizes are not available. The method is much faster and more reliable than those involving separation from other alpha-emitters, electroplating and alpha-spectrometry. A number of tracer experiments was performed in order to optimize the conditions for coprecipitation of 241Am from sediment leachates. The general outline of the determination of americium is also given.

  12. Survey parameters for detecting 21cm - Lyα emitter cross correlations with the Square Kilometre Array

    NASA Astrophysics Data System (ADS)

    Hutter, Anne; Trott, Cathryn M.; Dayal, Pratika

    2018-06-01

    Detections of the cross correlation signal between the 21cm signal during reionization and high-redshift Lyman Alpha emitters (LAEs) are subject to observational uncertainties which mainly include systematics associated with radio interferometers and LAE selection. These uncertainties can be reduced by increasing the survey volume and/or the survey luminosity limit, i.e. the faintest detectable Lyman Alpha (Lyα) luminosity. We use our model of high-redshift LAEs and the underlying reionization state to compute the uncertainties of the 21cm-LAE cross correlation function at z ≃ 6.6 for observations with SKA1-Low and LAE surveys with Δz = 0.1 for three different values of the average IGM ionization state (⟨χHI⟩≃ 0.1, 0.25, 0.5). At z ≃ 6.6, we find SILVERRUSH type surveys, with a field of view of 21 deg2 and survey luminosity limits of Lα ≥ 7.9 × 1042erg s-1, to be optimal to distinguish between an inter-galactic medium (IGM) that is 50%, 25% and 10% neutral, while surveys with smaller fields of view and lower survey luminosity limits, such as the 5 and 10 deg2 surveys with WFIRST, can only discriminate between a 50% and 10% neutral IGM.

  13. Alpha-catenin-dependent recruitment of the centrosomal protein CAP350 to adherens junctions allows epithelial cells to acquire a columnar shape.

    PubMed

    Gavilan, Maria P; Arjona, Marina; Zurbano, Angel; Formstecher, Etienne; Martinez-Morales, Juan R; Bornens, Michel; Rios, Rosa M

    2015-03-01

    Epithelial morphogenesis involves a dramatic reorganisation of the microtubule cytoskeleton. How this complex process is controlled at the molecular level is still largely unknown. Here, we report that the centrosomal microtubule (MT)-binding protein CAP350 localises at adherens junctions in epithelial cells. By two-hybrid screening, we identified a direct interaction of CAP350 with the adhesion protein α-catenin that was further confirmed by co-immunoprecipitation experiments. Block of epithelial cadherin (E-cadherin)-mediated cell-cell adhesion or α-catenin depletion prevented CAP350 localisation at cell-cell junctions. Knocking down junction-located CAP350 inhibited the establishment of an apico-basal array of microtubules and impaired the acquisition of columnar shape in Madin-Darby canine kidney II (MDCKII) cells grown as polarised epithelia. Furthermore, MDCKII cystogenesis was also defective in junctional CAP350-depleted cells. CAP350-depleted MDCKII cysts were smaller and contained either multiple lumens or no lumen. Membrane polarity was not affected, but cortical microtubule bundles did not properly form. Our results indicate that CAP350 may act as an adaptor between adherens junctions and microtubules, thus regulating epithelial differentiation and contributing to the definition of cell architecture. We also uncover a central role of α-catenin in global cytoskeleton remodelling, in which it acts not only on actin but also on MT reorganisation during epithelial morphogenesis.

  14. Alpha-catenin-Dependent Recruitment of the Centrosomal Protein CAP350 to Adherens Junctions Allows Epithelial Cells to Acquire a Columnar Shape

    PubMed Central

    Zurbano, Angel; Formstecher, Etienne; Martinez-Morales, Juan R.; Bornens, Michel; Rios, Rosa M.

    2015-01-01

    Epithelial morphogenesis involves a dramatic reorganisation of the microtubule cytoskeleton. How this complex process is controlled at the molecular level is still largely unknown. Here, we report that the centrosomal microtubule (MT)-binding protein CAP350 localises at adherens junctions in epithelial cells. By two-hybrid screening, we identified a direct interaction of CAP350 with the adhesion protein α-catenin that was further confirmed by co-immunoprecipitation experiments. Block of epithelial cadherin (E-cadherin)-mediated cell-cell adhesion or α-catenin depletion prevented CAP350 localisation at cell-cell junctions. Knocking down junction-located CAP350 inhibited the establishment of an apico-basal array of microtubules and impaired the acquisition of columnar shape in Madin-Darby canine kidney II (MDCKII) cells grown as polarised epithelia. Furthermore, MDCKII cystogenesis was also defective in junctional CAP350-depleted cells. CAP350-depleted MDCKII cysts were smaller and contained either multiple lumens or no lumen. Membrane polarity was not affected, but cortical microtubule bundles did not properly form. Our results indicate that CAP350 may act as an adaptor between adherens junctions and microtubules, thus regulating epithelial differentiation and contributing to the definition of cell architecture. We also uncover a central role of α-catenin in global cytoskeleton remodelling, in which it acts not only on actin but also on MT reorganisation during epithelial morphogenesis. PMID:25764135

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scott, B.R.; Muggenburg, B.A.; Welsh, C.A.

    The alpha emitter plutonium-238 ({sup 238}Pu), which is produced in uranium-fueled, light-water reactors, is used as a thermoelectric power source for space applications. Inhalation of a mixed oxide form of Pu is the most likely mode of exposure of workers and the general public. Occupational exposures to {sup 238}PuO{sub 2} have occurred in association with the fabrication of radioisotope thermoelectric generators. Organs and tissue at risk for deterministic and stochastic effects of {sup 238}Pu-alpha irradiation include the lung, liver, skeleton, and lymphatic tissue. Little has been reported about the effects of inhaled {sup 238}PuO{sub 2} on peripheral blood cell countsmore » in humans. The purpose of this study was to investigate hematological responses after a single inhalation exposure of Beagle dogs to alpha-emitting {sup 238}PuO{sub 2} particles and to extrapolate results to humans.« less

  16. Tailoring Thin Film-Lacquer Coatings for Space Application

    NASA Technical Reports Server (NTRS)

    Peters, Wanda C.; Harris, George; Miller, Grace; Petro, John

    1998-01-01

    Thin film coatings have the capability of obtaining a wide range of thermal radiative properties, but the development of thin film coatings can sometimes be difficult and costly when trying to achieve highly specular surfaces. Given any space mission's thermal control requirements, there is often a need for a variation of solar absorptance (Alpha(s)), emittance (epsilon) and/or highly specular surfaces. The utilization of thin film coatings is one process of choice for meeting challenging thermal control requirements because of its ability to provide a wide variety of Alpha(s)/epsilon ratios. Thin film coatings' radiative properties can be tailored to meet specific thermal control requirements through the use of different metals and the variation of dielectric layer thickness. Surface coatings can be spectrally selective to enhance radiative coupling and decoupling. The application of lacquer to a surface can also provide suitable specularity for thin film application without the cost and difficulty associated with polishing.

  17. Monte Carlo calculations of the cellular S-values for α-particle-emitting radionuclides incorporated into the nuclei of cancer cells of the MDA-MB231, MCF7 and PC3 lines.

    PubMed

    Rojas-Calderón, E L; Ávila, O; Ferro-Flores, G

    2018-05-01

    S-values (dose per unit of cumulated activity) for alpha particle-emitting radionuclides and monoenergetic alpha sources placed in the nuclei of three cancer cell models (MCF7, MDA-MB231 breast cancer cells and PC3 prostate cancer cells) were obtained by Monte Carlo simulation. The MCNPX code was used to calculate the fraction of energy deposited in the subcellular compartments due to the alpha sources in order to obtain the S-values. A comparison with internationally accepted S-values reported by the MIRD Cellular Committee for alpha sources in three sizes of spherical cells was also performed leading to an agreement within 4% when an alpha extended source uniformly distributed in the nucleus is simulated. This result allowed to apply the Monte Carlo Methodology to evaluate S-values for alpha particles in cancer cells. The calculation of S-values for nucleus, cytoplasm and membrane of cancer cells considering their particular geometry, distribution of the radionuclide source and chemical composition by means of Monte Carlo simulation provides a good approach for dosimetry assessment of alpha emitters inside cancer cells. Results from this work provide information and tools that may help researchers in the selection of appropriate radiopharmaceuticals in alpha-targeted cancer therapy and improve its dosimetry evaluation. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Magnesium Induced Nucleophile Activation in the Guanylyltransferase mRNA Capping Enzyme

    PubMed Central

    Swift, Robert V.; Ong, Chau D.; Amaro, Rommie E.

    2012-01-01

    The messenger RNA guanylyltransferase, or mRNA capping enzyme, co-transcriptionally caps the 5′-end of nascent mRNA with GMP during the second in a set of three enzymatic reactions that result in the formation of an N7-methyl guanosine cap during mRNA maturation. The mRNA capping enzyme is characterized, in part, by a conserved lysine nucleophile that attacks the alpha-phosphorous atom of GTP, forming a lysine-GMP intermediate. Experiments have firmly established that magnesium is required for efficient intermediate formation, but have provided little insight into the requirement’s molecular origins. Using empirical and thermodynamic integration pKa estimates, along with conventional MD simulations, we show that magnesium binding likely activates the lysine nucleophile by increasing its acidity and by biasing the deprotonated nucleophile into conformations conducive to intermediate formation. These results provide additional functional understanding of an important enzyme in the mRNA transcript life cycle and allow functional analogies to be drawn that affect our understanding of the metal dependence of related superfamily members. PMID:23205906

  19. Confirmation of a Steep Luminosity Function for Ly alpha Emitters at z 5.7: a Major Component of Reionization

    NASA Technical Reports Server (NTRS)

    Dressler, Alan; Henry, Alaina L.; Martin, Crystal L.; Sawicki, Marcin; McCarthy, Patrick; Villaneuva, Edward

    2014-01-01

    We report the first direct and robust measurement of the faint-end slope of the Ly-alpha emitter (LAE) luminosity function at z = 5.7. Candidate LAEs from a low-spectral-resolution blind search with IMACS on Magellan- Baade were targeted at higher resolution to distinguish high redshift LAEs from foreground galaxies. All but 2 of our 42 single-emission-line systems are fainter than F = 2.0×10(exp-17) ergs s(exp-1) cm(exp-2), making these the faintest emission-lines observed for a z = 5.7 sample with known completeness, an essential property for determining the faint end slope of the LAE luminosity function. We find 13 LAEs as compared to 29 foreground galaxies, in very good agreement with the modeled foreground counts predicted in Dressler et al. (2011a) that had been used to estimate a faint-end slope of alpha = -2.0 for the LAE luminosity function. A 32% LAE fraction, LAE/(LAE+foreground) within the flux interval F = 2-20 × 10(exp-18) ergs s(exp-1) cm(exp-2) constrains the faint end slope of the luminosity function to -1.95 greater than alpha greater than -2.35 (1 delta). We show how this steep LF should provide, to the limit of our observations, more than 20% of the flux necessary to maintain ionization at z = 5.7, with a factor-of-ten extrapolation in flux reaching more than 55%. We suggest that this bodes well for a comparable contribution by similar, low-mass star forming galaxies at higher-redshift - within the reionization epoch at z greater than approximately 7, only 250 Myr earlier - and that such systems provide a substantial, if not dominant, contribution to the late-stage reionization of the IGM.

  20. Clinical audit project in undergraduate medical education curriculum: an assessment validation study

    PubMed Central

    Steketee, Carole; Mak, Donna

    2016-01-01

    Objectives To evaluate the merit of the Clinical Audit Project (CAP) in an assessment program for undergraduate medical education using a systematic assessment validation framework. Methods A cross-sectional assessment validation study at one medical school in Western Australia, with retrospective qualitative analysis of the design, development, implementation and outcomes of the CAP, and quantitative analysis of assessment data from four cohorts of medical students (2011- 2014). Results The CAP is fit for purpose with clear external and internal alignment to expected medical graduate outcomes.  Substantive validity in students’ and examiners’ response processes is ensured through relevant methodological and cognitive processes. Multiple validity features are built-in to the design, planning and implementation process of the CAP.  There is evidence of high internal consistency reliability of CAP scores (Cronbach’s alpha > 0.8) and inter-examiner consistency reliability (intra-class correlation>0.7). Aggregation of CAP scores is psychometrically sound, with high internal consistency indicating one common underlying construct.  Significant but moderate correlations between CAP scores and scores from other assessment modalities indicate validity of extrapolation and alignment between the CAP and the overall target outcomes of medical graduates.  Standard setting, score equating and fair decision rules justify consequential validity of CAP scores interpretation and use. Conclusions This study provides evidence demonstrating that the CAP is a meaningful and valid component in the assessment program. This systematic framework of validation can be adopted for all levels of assessment in medical education, from individual assessment modality, to the validation of an assessment program as a whole.  PMID:27716612

  1. Clinical audit project in undergraduate medical education curriculum: an assessment validation study.

    PubMed

    Tor, Elina; Steketee, Carole; Mak, Donna

    2016-09-24

    To evaluate the merit of the Clinical Audit Project (CAP) in an assessment program for undergraduate medical education using a systematic assessment validation framework. A cross-sectional assessment validation study at one medical school in Western Australia, with retrospective qualitative analysis of the design, development, implementation and outcomes of the CAP, and quantitative analysis of assessment data from four cohorts of medical students (2011- 2014). The CAP is fit for purpose with clear external and internal alignment to expected medical graduate outcomes.  Substantive validity in students' and examiners' response processes is ensured through relevant methodological and cognitive processes. Multiple validity features are built-in to the design, planning and implementation process of the CAP.  There is evidence of high internal consistency reliability of CAP scores (Cronbach's alpha > 0.8) and inter-examiner consistency reliability (intra-class correlation>0.7). Aggregation of CAP scores is psychometrically sound, with high internal consistency indicating one common underlying construct.  Significant but moderate correlations between CAP scores and scores from other assessment modalities indicate validity of extrapolation and alignment between the CAP and the overall target outcomes of medical graduates.  Standard setting, score equating and fair decision rules justify consequential validity of CAP scores interpretation and use. This study provides evidence demonstrating that the CAP is a meaningful and valid component in the assessment program. This systematic framework of validation can be adopted for all levels of assessment in medical education, from individual assessment modality, to the validation of an assessment program as a whole.

  2. Guanosine 5'-triphosphate binding protein (G/sub i/) and two additional pertussis toxin substrates associated with muscarinic receptors in rat heart myocytes: characterization and age dependency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moscona-Amir, E.; Henis, Y.I.; Sokolovsky, M.

    1988-07-12

    The coupling of muscarinic receptors with G-proteins was investigated in cultured myocytes prepared from the hearts of newborn rats. The coupling was investigated in both young (5 days after plating) and aged (14 days after plating) cultures, in view of the completely different effects of 5'-guanylyl imidodiphosphate (Gpp(NH)p) on muscarinic agonist binding to homogenates from young vs aged cultures. Pretreatment of cultures from both ages by Bordetella pertussis toxin (IAP) was found to eliminate any Gpp(NH)p effect on carbamylcholine binding. IAP by itself induced a rightward shift in the carbamylcholine competition curve in homogenates from aged cultures, but no suchmore » effect was observed in homogenates from young cultures. IAP-catalyzed (/sup 32/P)ADP-ribosylation of membrane preparations from young and aged cultures revealed major differences between them. Young cultures exhibited a major IAP substrate at 40 kDa, which was also recognized by anti-..cap alpha../sub i/ antibodies, and two novel IAP substrates at 28 and 42 kDa, which were weakly ADP-ribosylated by the toxin and were not recognized with either anti-..cap alpha../sub i/ or anti-..cap alpha../sub 0/ antibodies. In aged cultures, only the 40-kDa band (ribosylated to a lower degree) was detected. The parallel age-dependent changes in the three IAP substrates (28, 40, and 42 kDa) and in the interactions of the G-protein(s) with the muscarinic receptors strongly suggest close association between the two phenomena. All of these age-dependent changes in the G-protein related parameters were prevented by phosphatidylcholine-liposome treatment of the aged cultures. The role of the membrane lipid composition in these phenomena is discussed.« less

  3. Host-pathogen interactions. XXIX. Oligogalacturonides released from sodium polypectate by endopolygalacturonic acid lyase are elicitors of phytoalexins in soybean. [Glycine max L

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, K.R.; Darvill, A.G.; Albersheim, P.

    1986-02-01

    Recent studies have demonstrated that an apparently homogeneous preparation of an ..cap alpha..-1,4-D-endopolygalacturonic acid lyase (EC 4.2,2.2) isolated from the phytopathogenic bacterium Erwinia carotovora induced phytoalexin accumulation in cotyledons of soybean (Glycine max (L.) Merr. cv Wayne) and that this pectin-degrading enzyme released heat-stable elicitors of phytoalexins from soybean cell walls, citrus pectin, and sodium polypectate. The present paper reports the purification, by anion-exchange chromatography on QAE-Sephadex columns followed by gel-permeation chromatography on a Bio-Gel P-6 column, of the two fractions with highest specific elicitor activity present in a crude elicitor-preparation obtained by lyase treatment of sodium polypectate. Structural analysismore » of the fraction with highest specific elicitor activity indicated that the major, if not only, component was a decasaccharide of ..cap alpha..-1,4-D-galactosyluronic acid that contained the expected product of lyase cleavage, 4-deoxy-..beta..-L-5-threo-hexopyranos-4-enyluronic acid (4,5-unsaturated galactosyluronic acid), at the nonreducing terminus. This modified decagalacturonide fraction exhibited half-maximum and maximum elicitor activity at 1 microgram/cotyledon (6 micromolar) and 5 micrograms/cotyledon (32 micromolar) galactosyluronic acid equivalents, respectively. Reducing 90 to 95% of the carboxyl groups of the galactosyluronic acid residues abolished the elicitor activity of the decagalacturonide fraction. The second most elicitor-active fraction contained mostly undeca-..cap alpha..-1,4-D-galactosyluronic acid that contained 4,5-unsaturated galactosyluronic acid at the nonreducing termini. This fraction exhibited half-maximum and maximum elicitor activity at approximately 3 micrograms/cotyledon (17 micromolar) and 6 micrograms/cotyledon (34 micromolar) galactosyluronic acid equivalents, respectively.« less

  4. Inhibition of metabolism and DNA binding of polycyclic aromatic hydrocarbons (PAHs) by plant phenols in epidermis of SENCAR mice

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Das, M.; Bik, D.P.; Bickers, D.R.

    1986-03-05

    Naturally occurring plant phenols such as tannic acid (TA), quercetin (QT), myricetin (MY) and anthraflavic acid (AA) have been shown to inhibit the mutagenicity of several bay-region diolepoxides of PAHs. Since skin is a target for PAH carcinogenesis, they investigated the effect of these plant phenols on epidermal aryl hydrocarbon hydroxylase (AHH) activity and the binding of PAHs to DNA in SENCAR mice. Each of the plant phenols tested was found to be an in vitro and in vivo inhibitor of epidermal AHH activity with I/sub 50/ values ranging from 4.4 x 10/sup -5/ - 12.4 x 10/sup -5/M inmore » control and 3-methylcholanthrene (MCA) pretreated skin. On an equimolar basis TA was the most potent inhibitor with a Ki of 81 ..mu..M. Incubation of TA, QT, MY and AA with epidermal microsomes resulted in varying degrees of inhibition of enzyme mediated covalent binding of benzo(a)pyrene (BP) to calf thymus DNA. TA (25 ..mu..M) showed maximum inhibition (64%). A single topical application (12 ..mu..mol) of TA, QT, MY and AA resulted in significant decrease in the binding of BP, BP-7,8-diol and 7,12-dimethylbenz(a)anthracene to epidermal DNA. The formation of (+)-7..beta..,8..cap alpha..-dihydroxy-9..cap alpha..,10..cap alpha..-epoxy-7,8,9,10-tetrahydro-BP-deoxyguanine adduct in epidermis was significantly reduced (62-86%) following topical application of the plant phenols. Their results suggest that some of these plant phenols have substantial though variable potential to modify the risk of PAHs induced skin carcinogenicity.« less

  5. Bonding in the first-row diatomic molecules within the local spin-density approximation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Painter, G.S.; Averill, F.W.

    1982-08-15

    The Hohenberg-Kohn-Sham density-functional equations in the local spin-density approximation (LSDA) have been solved with essentially no loss of accuracy for dimers of the first row of the Periodic Table with the use of a fully-self-consistent spin-polarized Gaussian-orbital approach. Spectroscopic constants (binding energies, equilibrium separations, and ground-state vibrational frequencies) have been derived from the calculated potential-energy curves. Intercomparison of results obtained using the exchange-correlation functionals of Slater (scaled exchange or X..cap alpha..), Gunnarsson and Lundqvist (GL), and Vosko, Wilk, and Nusair (VWN) permits assessment of the relative merits of each and serves to identify general shortcomings in the LSDA. Basic trendsmore » are similar for each functional, but the treatment of the spin dependence of the exchange-correlation energy in the GL and VWN functionals yields a variation of the binding energy across the series which is more systematic than that in the X..cap alpha.. approximation. Agreement between the present results and those of Dunlap, Connolly, and Sabin in the X..cap alpha.., approximation confirms the accuracy of the variational charge-density-fit procedure used in the latter work. The refinements in correlation treatment within the VWN functional are reflected in improvements in binding energies which are only slight for most dimers in the series. This behavior is attributed to the error remaining in the exchange channel within the LSDA and demonstrates the necessity for self-interaction corrections for more accurate binding-energy determinations. Within the current LSDA, absolute accuracies of the VWN functional for the first-row dimers are within 2.3 eV for binding energies, 0.07 a.u. for bond lengths, and approx.200 cm/sup -1/ for vibrational frequencies.« less

  6. ESR study of electron reactions with esters and triglycerides

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sevilla, M.D.; Morehouse, K.M.; Swarts, S.

    1981-04-02

    Reactions which occurred after electron attachment at 77K to a number of small carboxylic acid esters and triglycerides in an aqueous glass are reported. Most ester anions are found to decay on warming to form alkyl radicals by ..beta.. scission: RC(O/sup -/)OR' ..-->.. RCO/sub 2//sup -/ + R'.. The alkyl radical (R'.) produced by annealing is found to abstract hydrogen from the parent ester at an ..cap alpha..-carbon site, R'.+ R''CH/sub 2/CO/sub 2/R' ..-->.. R''CHCO/sub 2/R', or in the case of ethyl formate from the formate hydrogen, CH/sub 3/CH/sub 2/.+ HCO/sub 2/C/sub 2/H/sub 5/ ..-->.. C/sub 2/H/sub 6/ +.CO/sub 2/C/submore » 2/H/sub 5/. Results found for the methyl formate anion suggest hydrogen abstraction by the anion itself may compete with alkyl radical formation. The anion of the triglyceride triacetin is found to undergo an analogous mechanism to the ester anions producing the propane diol diester radical, .CH/sub 2/CH(Ac)CH/sub 2/(Ac), Ac = acetate. This species subsequently abstracts hydrogen from the parent compound to produce the ..cap alpha..-carbon radical, .CH/sub 2/CO/sub 2/R. Results found after annealing the tripropionin radical anion give evidence for abstraction from the ..cap alpha.. carbon in the propionate side groups producing CH/sub 3/CHCO/sub 2/R. Studies of a ..gamma..-irradiated ester (ethyl myristate) and two triglycerides (tripalmitin and tristearin) yield results which suggest that the mechanism of ester anion decay found in aqueous glasses applies to ..gamma..-irradiated neat long-chain esters and triglycerides. Results found in this work are compared to the results of product analysis.« less

  7. Structural elucidation of the Brucella melitensis M antigen by high-resolution NMR at 500 MHz

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bundle, D.R.; Cherwonogrodzky, J.W.; Perry, M.B.

    The Brucella M antigen from the species type strain Brucella melitensis 16M has been identified as a component of the cell wall lipopolysaccharide (LPS). O polysaccharide liberated from this LPS by mild acid hydrolysis exhibited M activity in serological tests and was shown to be a homopolymer of 4-formamido-4,6-dideoxy-..cap alpha..-D-mannopyranosyl residues arranged in an oligosaccharide repeating unit as judged by sodium dodecyl sulfate-polyacrylamide gel electrophoresis of the native lipopolysaccharide. Structural analysis of the O polysaccharide by NMR methods was difficult due to apparent microheterogeneity of the repeating unit, which was in fact caused by the presence of rotational isomers ofmore » the N-formyl moiety. This problem was resolved by chemical modification of the polysaccharide to its amino and N-acetyl derivatives, the 500-MHz /sup 1/H and 125-MHz /sup 13/C NMR spectra of which could be analyzed in terms of a unique structure through application of pH-dependent ..beta..-shifts and two-dimensional techniques that included COSY, relayed COSY, and NOESY experiments together with heteronuclear C/H shift correlation spectroscopy. On the basis of these experiments and supported by methylation and periodate oxidation data, the structure of the M polysaccharide was determined as a linear polymer of unbranched pentasaccharide repeating units consisting of four 1,2-linked and one 1,3-lined 4,6-dideoxy-4-formamido-..cap alpha..-D-mannopyranosyl residues. The marked structural similarity of the M antigen and the A antigen, which is known to be a 1,2-linked homopolysaccharide of 4,6-dideoxy-4-formamido-..cap alpha..-D-mannopyranosyl units, accounts for cross-serological reactions of the two and the long-standing confusion surrounding the nature of their antigenic determinants.« less

  8. Enhanced adhesion by high energy bombardment

    NASA Technical Reports Server (NTRS)

    Griffith, Joseph E. (Inventor); Qiu, Yuanxun (Inventor); Tombrello, Thomas A. (Inventor)

    1984-01-01

    Films (12) of gold, copper, silicon nitride, or other materials are firmly bonded to insulator substrates (12) such as silica, a ferrite, or Teflon (polytetrafluorethylene) by irradiating the interface with high energy ions. Apparently, track forming processes in the electronic stopping region cause intermixing in a thin surface layer resulting in improved adhesion without excessive doping. Thick layers can be bonded by depositing or doping the interfacial surfaces with fissionable elements or alpha emitters.

  9. Stochastic simulation of radium-223 dichloride therapy at the sub-cellular level

    NASA Astrophysics Data System (ADS)

    Gholami, Y.; Zhu, X.; Fulton, R.; Meikle, S.; El-Fakhri, G.; Kuncic, Z.

    2015-08-01

    Radium-223 dichloride (223Ra) is an alpha particle emitter and a natural bone-seeking radionuclide that is currently used for treating osteoblastic bone metastases associated with prostate cancer. The stochastic nature of alpha emission, hits and energy deposition poses some challenges for estimating radiation damage. In this paper we investigate the distribution of hits to cells by multiple alpha particles corresponding to a typical clinically delivered dose using a Monte Carlo model to simulate the stochastic effects. The number of hits and dose deposition were recorded in the cytoplasm and nucleus of each cell. Alpha particle tracks were also visualized. We found that the stochastic variation in dose deposited in cell nuclei (≃ 40%) can be attributed in part to the variation in LET with pathlength. We also found that ≃ 18% of cell nuclei receive less than one sigma below the average dose per cell (≃ 15.4 Gy). One possible implication of this is that the efficacy of cell kill in alpha particle therapy need not rely solely on ionization clustering on DNA but possibly also on indirect DNA damage through the production of free radicals and ensuing intracellular signaling.

  10. RADIOACTIVITY IN TEXAS STREAMS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Drynan, W.R.; Gloyna, E.F.; Smallhorst, D.F.

    1961-07-01

    Early results from a 3-year program to collect base-line data on radioactivity in Texas waters are reported. When preliminary teste indicate the presence of significant quantities of either alpha or beta emitters, a gamma spectrum and a radiochemical separation of Sr and Ra is made. The instruments most frequently used in counting river samples are of the proportional gas flow type. Most of the samples collected throughout the state had less than 50 mu mu c/l of beta activity and 10 mu mu c/l of alpha activity. Tables are given of the gross radioactivity analyses of samples from the Canadianmore » and Neches Rivers in Texas along with the dates the samples were collected. (P.C.H.)« less

  11. Physical Conditions of the Interstellar Medium in Star-forming Galaxies at z1.5

    NASA Technical Reports Server (NTRS)

    Hayashi, Masao; Ly, Chun; Shimasaku, Kazuhiro; Motohara, Kentaro; Malkan, Matthew A.; Nagao, Tohru; Kashikawa, Nobunari; Goto, Ryosuke; Naito, Yoshiaki

    2015-01-01

    We present results from Subaru/FMOS near-infrared (NIR) spectroscopy of 118 star-forming galaxies at z approximately equal to 1.5 in the Subaru Deep Field. These galaxies are selected as [O II] lambda 3727 emitters at z approximately equal to 1.47 and 1.62 from narrow-band imaging. We detect H alpha emission line in 115 galaxies, [O III] lambda 5007 emission line in 45 galaxies, and H Beta, [N II] lambda 6584, and [S II]lambda lambda 6716, 6731 in 13, 16, and 6 galaxies, respectively. Including the [O II] emission line, we use the six strong nebular emission lines in the individual and composite rest-frame optical spectra to investigate physical conditions of the interstellar medium in star-forming galaxies at z approximately equal to 1.5. We find a tight correlation between H alpha and [O II], which suggests that [O II] can be a good star formation rate (SFR) indicator for galaxies at z approximately equal to 1.5. The line ratios of H alpha / [O II] are consistent with those of local galaxies. We also find that [O II] emitters have strong [O III] emission lines. The [O III]/[O II] ratios are larger than normal star-forming galaxies in the local Universe, suggesting a higher ionization parameter. Less massive galaxies have larger [O III]/[O II] ratios. With evidence that the electron density is consistent with local galaxies, the high ionization of galaxies at high redshifts may be attributed to a harder radiation field by a young stellar population and/or an increase in the number of ionizing photons from each massive star.

  12. Thermal Optical Properties of Lunar Dust Simulants and Their Constituents

    NASA Technical Reports Server (NTRS)

    Gaier, James R.; Ellis, Shaneise; Hanks, Nichole

    2011-01-01

    The total reflectance spectra of lunar simulant dusts (less than 20 micrometer particles) were measured in order to determine their integrated solar absorptance (alpha) and their thermal emittance (e) for the purpose of analyzing the effect of dust on the performance of thermal control surfaces. All of the simulants except one had a wavelength-dependant reflectivity (p(lambda)) near 0.10 over the wavelength range of 8 to 25 micrometers, and so are highly emitting at room temperature and lower. The 300 K emittance (epsilon) of all the lunar simulants except one ranged from 0.78 to 0.92. The exception was Minnesota Lunar Simulant 1 (MLS-1), which has little or no glassy component. In all cases the epsilon was lower for the less 20 micrometer particles than for larger particles reported earlier. There was considerably more variation in the lunar simulant reflectance in the solar spectral range (250 to 2500 nanometers) than in the thermal infrared. As expected, the lunar highlands simulants were more reflective in this wavelength range than the lunar mare simulants. The integrated solar absorptance (alpha) of the simulants ranged from 0.39 to 0.75. This is lower than values reported earlier for larger particles of the same simulants (0.41 to 0.82), and for representative mare and highlands lunar soils (0.74 to 0.91). Since the alpha of some mare simulants more closely matched that of highlands lunar soils, it is recommended that and values be the criteria for choosing a simulant for assessing the effects of dust on thermal control surfaces, rather than whether a simulant has been formulated as a highlands or a mare simulant.

  13. Increased helix and protein stability through the introduction of a new tertiary hydrogen bond.

    PubMed

    Peterson, R W; Nicholson, E M; Thapar, R; Klevit, R E; Scholtz, J M

    1999-03-12

    In an effort to quantify the importance of hydrogen bonding and alpha-helix formation to protein stability, a capping box motif was introduced into the small phosphocarrier protein HPr. Previous studies had confirmed that Ser46, at the N-cap position of the short helix-B in HPr, serves as an N-cap in solution. Thus, only a single-site mutation was required to produce a canonical S-X-X-E capping box: Lys49 at the N3 position was substituted with a glutamic acid residue. Thermal and chemical denaturation studies on the resulting K49E HPr show that the designed variant is approximately 2 kcal mol-1 more stable than the wild-type protein. However, NMR studies indicate that the side-chain of Glu49 does not participate in the expected capping H-bond interaction, but instead forms a new tertiary H-bond that links helix-B to the four-stranded beta-sheet of HPr. Here, we demonstrate that a strategy in which new non-native H-bonds are introduced can generate proteins with increased stability. We discuss why the original capping box design failed, and compare the energetic consequences of the new tertiary side-chain to main-chain H-bond with a local (helix-capping) side-chain to main-chain H-bond on the protein's global stability. Copyright 1999 Academic Press.

  14. Silicon Carbide Radioisotope Batteries

    NASA Technical Reports Server (NTRS)

    Rybicki, George C.

    2005-01-01

    The substantial radiation resistance and large bandgap of SiC semiconductor materials makes them an attractive candidate for application in a high efficiency, long life radioisotope battery. To evaluate their potential in this application, simulated batteries were constructed using SiC diodes and the alpha particle emitter Americium Am-241 or the beta particle emitter Promethium Pm-147. The Am-241 based battery showed high initial power output and an initial conversion efficiency of approximately 16%, but the power output decayed 52% in 500 hours due to radiation damage. In contrast the Pm-147 based battery showed a similar power output level and an initial conversion efficiency of approximately 0.6%, but no degradation was observed in 500 hours. However, the Pm-147 battery required approximately 1000 times the particle fluence as the Am-242 battery to achieve a similar power output. The advantages and disadvantages of each type of battery and suggestions for future improvements will be discussed.

  15. Beta/gamma and alpha backgrounds in CRESST-II Phase 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strauss, R.; Angloher, G.; Ferreiro Iachellini, N.

    2015-06-01

    The experiment CRESST-II aims at the detection of dark matter with scintillating CaWO{sub 4} crystals operated as cryogenic detectors. Recent results on spin-independent WIMP-nucleon scattering from the CRESST-II Phase 2 allowed to probe a new region of parameter space for WIMP masses below 3 GeV/c{sup 2}. This sensitivity was achieved after background levels were reduced significantly. We present extensive background studies of a CaWO{sub 4} crystal, called TUM40, grown at the Technische Universität München. The average beta/gamma rate of 3.51/[kg keV day] (1-40 keV) and the total intrinsic alpha activity from natural decay chains of 3.08±0.04 mBq/kg are the lowestmore » reported for CaWO{sub 4} detectors. Contributions from cosmogenic activation, surface-alpha decays, external radiation and intrinsic alpha/beta emitters are investigated in detail. A Monte-Carlo based background decomposition allows to identify the origin of the majority of beta/gamma events in the energy region relevant for dark matter search.« less

  16. Supramolecular Inclusion in Cyclodextrins: A Pictorial Spectroscopic Demonstration

    ERIC Educational Resources Information Center

    Haldar, Basudeb; Mallick, Arabinda; Chattopadhyay, Nitin

    2008-01-01

    A spectroscopic experiment is presented that reveals that the hydrophobically end-modified water-soluble polymeric fluorophore, pyrene end-capped poly(ethylene oxide) (PYPY), interacts differently with [alpha], [beta], and [gamma]-cyclodextrins (CD) to form supramolecular inclusion complexes. The emission spectrum of PYPY in aqueous solution shows…

  17. Radionuclide injury to the lung.

    PubMed Central

    Dagle, G E; Sanders, C L

    1984-01-01

    Radionuclide injury to the lung has been studied in rats, hamsters, dogs, mice and baboons. Exposure of the lung to high dose levels of radionuclides produces a spectrum of progressively more severe functional and morphological changes, ranging from radiation pneumonitis and fibrosis to lung tumors. These changes are somewhat similar for different species. Their severity can be related to the absorbed radiation dose (measured in rads) produced by alpha, beta or gamma radiation emanating from various deposited radionuclides. The chemicophysical forms of radionuclides and spatial-temporal factors are also important variables. As with other forms of injury to the lung, repair attempts are highlighted by fibrosis and proliferation of pulmonary epithelium. Lung tumors are the principal late effect observed in experimental animals following pulmonary deposition of radionuclides at dose levels that do not result in early deaths from radiation pneumonitis or fibrosis. The predominant lung tumors described have been of epithelial origin and have been classified, in decreasing frequency of occurrence, as adenocarcinoma, bronchioloalveolar carcinoma, epidermoid carcinomas and combined epidermoid and adenocarcinoma. Mesothelioma and fibrosarcoma have been observed in rats, but less commonly in other species. Hemangiosarcomas were frequency observed in dogs exposed to beta-gamma emitters, and occasionally in rats exposed to alpha emitters. These morphologic changes in the lungs of experimental animals were reviewed and issues relevant to the prediction of human hazards discussed. PMID:6376095

  18. Exploring the Structure of the Distant Universe with MUSE Data Cubes

    NASA Astrophysics Data System (ADS)

    MacDougall, Mason; Christensen, Lise

    2018-01-01

    The mass distribution in intergalactic and circumgalactic space is not well known since it is difficult to characterize objects in the distant universe. An ideal tool for studying such distant structure is the Multi-Unit Spectroscopic Explorer (MUSE) of the Very Large Telescope array, which employs a wide field-of-view and a large spectral range to produce high spatial resolution datasets. Here we exploit the 2 spatial dimensions and 1 spectral dimension of a particular MUSE “data cube” to identify and characterize emission line sources near the line-of-sight to quasar PKS1937-101, which lies at a redshift of z=3.787. In particular, we search for galaxy companions to a z=3.572 Lyman-limit system measured in the quasar spectrum and find an associated Lyman-alpha emitter at z=3.556 with a projected distance of 30.2 kpc from the quasar line-of-sight. Through a combination of automated source extraction and manual investigation, we also identify 25 emission line galaxies and 1 other Lyman-alpha emitter in our field. The proximity of several of these objects to the quasar line-of-sight allows us to reliably identify absorption lines in the quasar spectrum that can be associated with observed emission lines with resolved fluxes. This will help characterize the metallicities and kinematics of galaxy halos and circumgalactic media in the early universe.

  19. Disc valve for sampling erosive process streams

    DOEpatents

    Mrochek, J.E.; Dinsmore, S.R.; Chandler, E.W.

    1984-08-16

    This is a patent for a disc-type, four-port sampling valve for service with erosive high temperature process streams. Inserts and liners of ..cap alpha..-silicon carbide respectively, in the faceplates and in the sampling cavities, limit erosion while providing lubricity for a smooth and precise operation. 1 fig.

  20. Development of optical monitor of alpha radiations based on CR-39.

    PubMed

    Joshirao, Pranav M; Shin, Jae Won; Vyas, Chirag K; Kulkarni, Atul D; Kim, Hojoong; Kim, Taesung; Hong, Seung-Woo; Manchanda, Vijay K

    2013-11-01

    Fukushima accident has highlighted the need to intensify efforts to develop sensitive detectors to monitor the release of alpha emitting radionuclides in the environment caused by the meltdown of the discharged spent fuel. Conventionally, proportional counting, scintillation counting and alpha spectrometry are employed to assay the alpha emitting radionuclides but these techniques are difficult to be configured for online operations. Solid State Nuclear Track Detectors (SSNTDs) offer an alternative off line sensitive technique to measure alpha emitters as well as fissile radionuclides at ultra-trace level in the environment. Recently, our group has reported the first ever attempt to use reflectance based fiber optic sensor (FOS) to quantify the alpha radiations emitted from (232)Th. In the present work, an effort has been made to develop an online FOS to monitor alpha radiations emitted from (241)Am source employing CR-39 as detector. Here, we report the optical response of CR-39 (on exposure to alpha radiations) employing techniques such as Atomic Force Microscopy (AFM) and Reflectance Spectroscopy. In the present work GEANT4 simulation of transport of alpha particles in the detector has also been carried out. Simulation includes validation test wherein the projected ranges of alpha particles in the air, polystyrene and CR-39 were calculated and were found to agree with the literature values. An attempt has been further made to compute the fluence as a function of the incidence angle and incidence energy of alphas. There was an excellent correlation in experimentally observed track density with the simulated fluence. The present work offers a novel approach to design an online CR-39 based fiber optic sensor (CRFOS) to measure the release of nanogram quantity of (241)Am in the environment. © 2013 Elsevier Ltd. All rights reserved.

  1. Evolution of spent nuclear fuel in dry storage conditions for millennia and beyond

    NASA Astrophysics Data System (ADS)

    Wiss, Thierry; Hiernaut, Jean-Pol; Roudil, Danièle; Colle, Jean-Yves; Maugeri, Emilio; Talip, Zeynep; Janssen, Arne; Rondinella, Vincenzo; Konings, Rudy J. M.; Matzke, Hans-Joachim; Weber, William J.

    2014-08-01

    Significant amounts of spent uranium dioxide nuclear fuel are accumulating worldwide from decades of commercial nuclear power production. While such spent fuel is intended to be reprocessed or disposed in geologic repositories, out-of-reactor radiation damage from alpha decay can be detrimental to its structural stability. Here we report on an experimental study in which radiation damage in plutonium dioxide, uranium dioxide samples doped with short-lived alpha-emitters and urano-thorianite minerals have been characterized by XRD, transmission electron microscopy, thermal desorption spectrometry and hardness measurements to assess the long-term stability of spent nuclear fuel to substantial alpha-decay doses. Defect accumulation is predicted to result in swelling of the atomic structure and decrease in fracture toughness; whereas, the accumulation of helium will produce bubbles that result in much larger gaseous-induced swelling that substantially increases the stresses in the constrained spent fuel. Based on these results, the radiation-ageing of highly-aged spent nuclear fuel over more than 10,000 years is predicted.

  2. Discovery and observation of BY Draconis variables

    NASA Astrophysics Data System (ADS)

    Bopp, B. W.; Noah, P. V.; Klimke, A.; Africano, J.

    1981-10-01

    The discovery of BY Draconis variables was efficiently accomplished by a spectroscopic survey of dK-M stars for weak H-alpha emissions, using 1-2 A resolution. The four BY Dra variables discovered are all spectroscopic binaries with P values lower than about 10 d, in light of which, it is noted that the onset of high surface activity and appearance of H-alpha emission occur sharply at v(equator) of approximately 5 km/sec. At v(equator) of about 3 km/sec, dK-M stars have low levels of surface activity. It is found that while there is a range of Ca II emission strength, and only the strongest emitters of this line are BY Dra and/or flare stars, the H-alpha feature changes abruptly to an emission feature signaling the onset of flaring and/or the BY Dra syndrome. An increase of the rotation rate above v(equator) 5 km/sec does not appear to increase the level of surface activity.

  3. Importance of the lid and cap domains for the catalytic activity of gastric lipases.

    PubMed

    Miled, N; Bussetta, C; De caro, A; Rivière, M; Berti, L; Canaan, S

    2003-09-01

    Human gastric lipase (HGL) is an enzyme secreted by the stomach, which is stable and active despite the highly acidic environment. It has been clearly established that this enzyme is responsible for 30% of the fat digestion processes occurring in human. This globular protein belongs to the alpha/beta hydrolase fold family and its catalytic serine is deeply buried under a domain called the extrusion domain, which is composed of a 'cap' domain and a segment consisting of 58 residues, which can be defined as a lid. The exact roles played by the cap and the lid domains during the catalytic step have not yet been elucidated. We have recently solved the crystal structure of the open form of the dog gastric lipase in complex with a covalent inhibitor. The detergent molecule and the inhibitor were mimicking a triglyceride substrate that would interact with residues belonging to both the cap and the lid domains. In this study, we have investigated the role of the cap and the lid domains, using site-directed mutagenesis procedures. We have produced truncated mutants lacking the lid and the cap. After expressing these mutants and purifying them, their activity was found to have decreased drastically in comparison with the wild type HGL. The lid and the cap domains play an important role in the catalytic reaction mechanism. Based on these results and the structural data (open form of DGL), we have pointed out the cap and the lid residues involved in the binding with the lipidic substrate.

  4. 1973 environmental monitoring report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hull, A.P.; Ash, J.A.

    1974-03-01

    >Results from radiation monitoring during 1973 in the environment of the Brookhaven National Laboratory are presented. Data are included on: the gross alpha and BETA activity and content of tritium and gamma-emitting radionuclides in surface air; gross BETA activity and gamma and tritium content in atmospheric precipitation; activities and concentration of gamma emitters in liquid effiuents and ground water; gross BETA , tritium and /sup 90/Sr in effluents; gross BETA and tritl um in surface waters; /sup 90/Sr and gamma- emitting radionuclides in river ecosystem; gross alpha , gross BETA , tritium, / sup 90/Sr, and /sup 137/Cs in groundmore » and well water; /sup 137/Cs, K, /sup 131/I, and /sup 90/Sr content in area milk; and gamma-emitting radionuclides in soils and grasses. (LCL)« less

  5. Plasma effects on the passive external thermal control coating of Space Station Freedom

    NASA Technical Reports Server (NTRS)

    Carruth, Ralph, Jr.; Vaughn, Jason A.; Holt, James M.; Werp, Richard; Sudduth, Richard D.

    1992-01-01

    The current baseline chromic acid anodized thermal control coating on 6061-T6 aluminum meteoroid debris (M/D) shields for SSF has been evaluated. The degradation of the solar absorptance, alpha, and the thermal emittance, epsilon, of chromic acid anodized aluminum due to dielectric breakdown in plasma was measured to predict the on-orbit lifetime of the SSF M/D shields. The lifetime of the thermal control coating was based on the surface temperatures achieved with degradation of the thermal control properties, alpha and epsilon. The temperatures of each M/D shield from first element launch (FEL) through FEL+15 years were analyzed. It is shown that the baseline thermal control coating cannot withstand the -140 V potential between the conductive structure of the SSF and the current plasma environment.

  6. Terahertz spin current pulses controlled by magnetic heterostructures

    NASA Astrophysics Data System (ADS)

    Kampfrath, T.; Battiato, M.; Maldonado, P.; Eilers, G.; Nötzold, J.; Mährlein, S.; Zbarsky, V.; Freimuth, F.; Mokrousov, Y.; Blügel, S.; Wolf, M.; Radu, I.; Oppeneer, P. M.; Münzenberg, M.

    2013-04-01

    In spin-based electronics, information is encoded by the spin state of electron bunches. Processing this information requires the controlled transport of spin angular momentum through a solid, preferably at frequencies reaching the so far unexplored terahertz regime. Here, we demonstrate, by experiment and theory, that the temporal shape of femtosecond spin current bursts can be manipulated by using specifically designed magnetic heterostructures. A laser pulse is used to drive spins from a ferromagnetic iron thin film into a non-magnetic cap layer that has either low (ruthenium) or high (gold) electron mobility. The resulting transient spin current is detected by means of an ultrafast, contactless amperemeter based on the inverse spin Hall effect, which converts the spin flow into a terahertz electromagnetic pulse. We find that the ruthenium cap layer yields a considerably longer spin current pulse because electrons are injected into ruthenium d states, which have a much lower mobility than gold sp states. Thus, spin current pulses and the resulting terahertz transients can be shaped by tailoring magnetic heterostructures, which opens the door to engineering high-speed spintronic devices and, potentially, broadband terahertz emitters.

  7. Radiotoxicity of Gadolinium-148 and Radium-223 in Mouse Testes: Relative Biological Effectiveness of Alpha-Particle Emitters In Vivo

    PubMed Central

    Howell, Roger W.; Goddu, S. Murty; Narra, Venkat R.; Fisher, Darrell R.; Schenter, Robert E.; Rao, Dandamudi V.

    2012-01-01

    The biological effects of radionuclides that emit α particles are of considerable interest in view of their potential for therapy and their presence in the environment. The present work is a continuation of our ongoing effort to study the radiotoxicity of α-particle emitters in vivo using the survival of murine testicular sperm heads as the biological end point. Specifically, the relative biological effectiveness (RBE) of very low-energy α particles (3.2 MeV) emitted by 148Gd is investigated and determined to be 7.4 ± 2.4 when compared to the effects of acute external 120 kVp X rays. This datum, in conjunction with our earlier results for 210Po and 212Pb in equilibrium with its daughters, is used to revise and extend the range of validity of our previous RBE–energy relationship for α particles emitted by tissue-incorporated radionuclides. The new empirical relationship is given by RBEα = 9.14 − 0.510 Eα, where 3 < Eα < 9 MeV. The validity of this empirical relationship is tested by determining the RBE of the prolific α-particle emitter 223Ra (in equilibrium with its daughters) experimentally in the same biological model and comparing the value obtained experimentally with the predicted value. The resulting RBE values are 5.4 ± 0.9 and 5.6, respectively. This close agreement strongly supports the adequacy of the empirical RBE-Eα relationship to predict the biological effects of α-particle emitters in Vivo. PMID:9052681

  8. Radioligand therapy of metastatic castration-resistant prostate cancer: current approaches.

    PubMed

    Awang, Zool Hilmi; Essler, Markus; Ahmadzadehfar, Hojjat

    2018-05-23

    Prostate Cancer is the forth most common type of cancer. Prostate-specific membrane antigen (PSMA) is anchored in the cell membrane of prostate epithelial cells. PSMA is highly expressed on prostate epithelial cells and strongly up-regulated in prostate cancer. Therefore it is an appropriate target for diagnostic and therapy of prostate cancer and its metastases. This article discusses several articles on radionuclide treatments in prostate cancer and the results on PSMA therapy with either beta or alpha emitters as a salvage therapy.

  9. Review of technical justification of assumptions and methods used by the Environmental Protection Agency for estimating risks avoided by implementing MCLs for radionuclides

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morris, S.C.; Rowe, M.D.; Holtzman, S.

    1992-11-01

    The Environmental Protection Agency (EPA) has proposed regulations for allowable levels of radioactive material in drinking water (40 CFR Part 141, 56 FR 33050, July 18, 1991). This review examined the assumptions and methods used by EPA in calculating risks that would be avoided by implementing the proposed Maximum Contaminant Levels for uranium, radium, and radon. Proposed limits on gross alpha and beta-gamma emitters were not included in this review.

  10. FEMOS - Advanced Neutron Monitor System for Waste Management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simon, G.G.; Sokcic-Kostic, M.

    2006-07-01

    FEMOS is a specially developed monitor to detect fissile materials for waste characterisation and it is also suitable to identify the main neutron emitters. The latest measuring prototype is in routine operation at FZK-HDB (Germany) for determining Plutonium content and alpha activity in 2001 and 4001 drums from the reprocessing plant Karlsruhe (WAK). Authorities license the measurement procedure. Routine measurements conducted over a period of about 6 years and the results show that all specified prerequisites are met with the required reliability. (authors)

  11. Effect of quench on alpha/beta pulse shape discrimination of liquid scintillation cocktails.

    PubMed

    DeVol, Timothy A; Theisen, Christopher D; DiPrete, David P

    2007-05-01

    The objectives of this paper are (1) to illustrate that knowledge of the external quench parameter is insufficient to properly setup a pulse shape discriminating liquid scintillation counter (LSC) for quantitative measurement, (2) to illustrate dependence on pulse shape discrimination on the radionuclide (more than just radiation and energy), and (3) to compare the pulse shape discrimination (PSD) of two commercial instruments. The effects various quenching agents, liquid scintillation cocktails, radionuclides, and LSCs have on alpha/beta pulse shape discriminating liquid scintillation counting were quantified. Alpha emitting radionuclides (239)Pu and (241)Am and beta emitter (90)Sr/(90)Y were investigated to quantify the nuclide dependence on alpha/beta pulse shape discrimination. Also, chemical and color quenching agents, nitromethane, nitric acid, and yellow dye impact on alpha/beta pulse shape discrimination using PerkinElmer Optiphase "HiSafe" 2 and 3, and Ultima Gold AB liquid scintillation cocktails were determined. The prepared samples were counted on the PerkinElmer Wallac WinSpectral 1414 alpha/beta pulse shape discriminating LSC. It was found that for the same level of quench, as measured by the external quench parameter, different quench agents influenced the pulse shape discrimination and the pulse shape discrimination parameters differently. The radionuclide also affects alpha/beta pulse shape discrimination. By comparison with the PerkinElmer Tri-carb 3150 TR/AB, the Wallac 1414 exhibited better pulse shape discrimination capability under the same experimental conditions.

  12. Laser surface treatment for porous and textured Ca-P bio-ceramic coating on Ti-6Al-4V.

    PubMed

    Paital, Sameer R; Dahotre, Narendra B

    2007-12-01

    In the present paper the feasibility of depositing a porous calcium phosphate (CaP) bio-ceramic coating using a continuous wave Nd:YAG laser on a Ti-6Al-4V substrate has been demonstrated. The advantages offered by such porous bio-ceramic coating are its inertness combined with the mechanical stability of the highly convoluted interface that develops when bone grows into the pores of ceramic. The formation of different phases with varying laser fluences is studied using x-ray diffraction (XRD). A quantitative estimation of the crystallite size and relative amounts of Ti and other predominant phases such as TiO(2) and alpha-tricalcium phosphate (alpha-TCP) were obtained. An increase in the crystallite size with increasing laser fluence is observed for all the above three phases. It is observed that TiO(2) is the predominant phase for all laser fluences and there is an increase in the alpha-TCP phase with increasing laser fluence. Surface porosity measurements indicated a decreasing trend with increasing laser fluence. Microhardness measurements in the cross section of samples showed a maximum hardness within the coating. The bioactivity of the coatings was further demonstrated by the formation of an apatite-like layer on the surface of the sample after being immersed in a simulated biofluid.

  13. Yang-Lee zeros, Julia sets, and their singularity spectra

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hu, B.; Lin, B.

    1989-05-01

    We have studied the global scaling properties of the Julia sets of the Yang-Lee zeros of the s-state Potts model on the diamond hierarchical lattice. The singularity spectrum f(..cap alpha..) and the generalized dimension D/sub q/ are calculated for different s values. General observations are made on their variations.

  14. N-(/sup 11/C)-methyl-p-substituted phentermine analogs as potential brain blood flow agents for positron tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kizuka, H.; Elmaleh, D.R.; Boudreaux, G.J.

    The addition of a methyl group to the ..cap alpha..-position of amphetamine increases both the lipophilicity of the agent and its resistance to metabolism by monoamine oxidase. In addition, since tritium substituted phenteramine analog studies suggested that the p-halo phentermines had a greater concentration in the brain and prolonged retention time, the authors evaluated the biological behavior of positron labeled ..cap alpha..-methylamphetamine (phenteramine) in rats, dogs and monkeys. The N-(/sup 11/C) methyl analogs of p-chloro (I) and p-fluoro (II) phentermines were prepared by methylation of their primary amines using /sup 11/Ch/sub 3/I. Biodistribution studies in rats shows brain uptake ismore » in the range of 1% dose/gr at 5 and 15 min for both agents. The activity in blood and eyes is low. Sequential images of the dogs' brain over 1 hour revealed a clearance of <15%. Images of the monkey brain were also obtained using a MGH positron camera PCR-I.« less

  15. Racemization of alanine by the alanine racemases from Salmonella typhimurium and Bacillus stearothermophilus: energetic reaction profiles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Faraci, W.S.; Walsh, C.T.

    1988-05-03

    Alanine racemases are bacterial pyridoxal 5'-phosphate (PLP) dependent enzymes providing D-alanine as an essential building block for biosynthesis of the peptidoglycan layer of the cell wall. Two isozymic alanine racemases, encoded by the dadB gene and the alr gene, from the Gram-negative mesophilic Salmonella typhimurium and one from the Gram-positive thermophilic Bacillus stearothermophilus have been examined for the racemization mechanism. Substrate deuterium isotope effects and solvent deuterium isotope effects have been measured in both L ..-->.. D and D..-->.. L directions for all three enzymes to assess the degree to which abstraction of the ..cap alpha..-proton or protonation of substratemore » PLP carbanion is limiting in catalysis. Additionally, experiments measuring internal return of ..cap alpha..-/sup 3/H from substrate to product and solvent exchange/substrate conversion experiments in /sup 3/H/sub 2/O have been used with each enzyme to examine the partitioning of substrate PLP carbanion intermediates and to obtain the relative heights of kinetically significant energy barriers in alanine racemase catalysis.« less

  16. Mobilization of tissue cadmium in mice and calves and reversal of cadmium induced tissue damage in calves by zinc

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reddy, C.S.; Mohammad, F.K.; Ganjam, V.K.

    1987-08-01

    Earlier studies demonstrated that simultaneous dietary Zn supplementation to calves fed Cd, significantly decreased the accumulation of Cd in liver, kidney and muscle. However, studies are lacking in evaluating the effectiveness of zinc in reducing Cd-burden in animals with pre-existing tissue Cd-load, a situation encountered in chronic Cd intoxication. This study examined the effects of oral Zn (AnO) on tissue Cd levels in mice. N-acetylcysteine (NAC) and sodium sulfate (SS) were also used to evaluate the effects of providing organic and inorganic sources of sulfur on tissue Cd levels. Following demonstration of reduced Cd levels in tissues of mice receivingmore » antidotal Zn, subsequent investigation was aimed at studying the reversal of Cd-induced changes by Zn. The authors also examined whether Cd-induced reduction in epididymal 5 ..cap alpha..-reductase activity could explain previously reported low levels of circulating dihydrotestosterone (DHT) following Cd treatment. The ability of Zn to reverse the inhibition of 5 ..cap alpha..-reductase activity by Cd was also examined.« less

  17. Study on great northern beans (Phaseolus vulgaris): effect of drum drying process on bean flour properties and effect on gamma radiation on bean starch properties

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rayas-Solis, P.

    Great Northern bean (Phaseolus vulgaris L.) drum dried flours at native pH of 6.54, pH 6 and 7 showed reduced activities of trypsin inhibitor, ..cap alpha..-amylase inhibitor, hemagglutinating titer, and nitrogen solubility. Electrophoretic analyses showed a slight modification of the native bean proteins, and the presence of at least four trypsin inhibitors. The study of the effect of 2.5-20 kGy irradiation doses on Great Northern beans showed essentially no modification of the electrophoretic mobility of the storage proteins or the trypsin inhibitors. Nitrogen solubility and hemagglutinating activity were essentially unchanged. With the 20 kGy dose, decrease in ..cap alpha..-amylase inhibitormore » activity, decrease reactive/available lysine content, and decrease cooking time of the irradiated beans after 11 months of storage were observed. Taste panel results indicated that the control and 20 kGy irradiated bean were significantly different at 5% level. At 20 kGy dose, the beans developed a partially water soluble brown color.« less

  18. Mutations in a gene encoding the. cap alpha. subunit of a Saccharomyces cerevisiae G protein indicate a role in mating pheromone signaling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jahng, K.Y.; Ferguson, J.; Reed, S.I.

    1988-06-01

    Mutations which allowed conjugation by Saccharomyces cerevisiae cells lacking a mating pheromone receptor gene were selected. One of the genes defined by such mutations was isolated from a yeast genomic library by complementation of a temperature-sensitive mutation and is identically to the gene GPA1 (also known as SCG1), recently shown to be highly homologous to gene encoding the ..cap alpha.. subunits of mammalian G proteins. Physiological analysis of temperature-sensitive gpal mutations suggests that the encoded G protein is involved in signaling in response to mating pheromones. Mutational disruption of G-protein activity causes cell-cycle arrest in G/sub 1/, deposition of mating-specificmore » cell surface aggultinins, and induction of pheromone-specific mRNa, all of which are responses to pheromone in wild-type cells. In addition, mutants can conjugate without the benefit of mating pheromone or pheromone receptor. A model is presented where the activated G protein has a negative impact on a constitutive signal which normally keeps the pheromone response repressed.« less

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Downes, R.A.

    Galactic plane ultraviolet-excess (uv-excess) objects covering about 1000 square degrees of sky were surveyed. Photographic plates were obtained with both uv and blue filters, to select the uv-excess candidates, which were then observed spectroscopically to determine their classification. Most of the objects selected were nearby early-type stars with low interstellar reddening; however, a collection of hot white dwarfs, subdwarf O (sdO) stars, subdwarf B (sdB) stars, and cataclysmic variables was also found. Photoelectric photometry was obtained for these stars and a statistical analysis was performed to determine the space densities and scale heights for the four classes of objects. Severalmore » interesting objects (or class of objects) were discovered, and data for some of these stars are presented. Among the peculiar objects found are an emission-line white dwarf similar to the pulsating PG 1159 stars, a Population II Wolf-Rayet star, a previously catalogued object with a strong Fe II emission-line spectrum, and a new class of object, resembling the sdB stars, that shows variable strength H..cap alpha.. absorption, with the H..cap alpha.. line sometimes completely filled in.« less

  20. Nucleotide sequence of the gene encoding the nitrogenase iron protein of Thiobacillus ferrooxidans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pretorius, I.M.; Rawlings, D.E.; O'Neill, E.G.

    1987-01-01

    The DNA sequence was determined for the cloned Thiobacillus ferrooxidans nifH and part of the nifD genes. The DNA chains were radiolabeled with (..cap alpha..-/sup 32/P)dCTP (3000 Ci/mmol) or (..cap alpha..-/sup 35/S)dCTP (400 Ci/mmol). A putative T. ferrooxidans nifH promoter was identified whose sequences showed perfect consensus with those of the Klebsiella pneumoniae nif promoter. Two putative consensus upstream activator sequences were also identified. The amino acid sequence was deduced from the DNA sequence. In a comparison of nifH DNA sequences from T. ferrooxidans and eight other nitrogen-fixing microbes, a Rhizobium sp. isolated from Parasponia andersonii showed the greatest homologymore » (74%) and Clostridium pasteurianum (nifH1) showed the least homology (54%). In the comparison of the amino acid sequences of the Fe proteins, the Rhizobium sp. and Rhizobium japonicum showed the greatest homology (both 86%) and C. pasteurianum (nifH1 gene product) demonstrated the least homology (56%) to the T. ferrooxidans Fe protein.« less

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nomura, S.; Enna, S.J.

    Tricyclic antidepressants (TCAs) have anticholinergic and ..cap alpha..-adrenergic blocking properties. The present study was undertaken to examine the effects of amitriptyline, imipramine, and desipramine on inositol phosphate accumulation, a brain second messenger system associated with cholinergic and adrenergic receptors. Whereas the TCAs were 28 to 400-fold weaker than atropine as inhibitors of /sup 3/H-QNB binding to brain cholinergic receptors, they were 600 to 2000-fold less active than atropine as inhibitors of carbachol-stimulated IP accumulation in brain. In contrast, the relative potencies of the TCAs and prazosin to inhibit norepinephrine-stimulated IP accumulation and /sup 3/H-prazosin binding appeared to be similar inmore » the two assays. The results suggest pharmacological differences between the cholinergic receptors labeled in the ONB binding assay and those mediating the IP response, whereas the ..cap alpha../sub 1/-adrenergic receptors appear to be similar in the two systems. Since atropine is considered a nonselective muscarinic antagonist, it is possible that the TCAs may differentiate between cholinergic receptor subtypes, which may be an important component of their clinical response.« less

  2. Direct /sup 125/I-radioligand assays for serum progesterone compared with assays involving extraction of serum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ratcliffe, W.A.; Corrie, J.E.T.; Dalziel, A.H.

    1982-06-01

    Two direct radioimmunoassays for progesterone in 50 ..mu..L of unextracted serum or plasma with assays involving extraction of serum were compared. The direct assays include the use of either danazol at pH 7.4 or 8-anilino-1-naphthalenesulfonic acid at pH 4.0 to displace progesterone from serum binding-proteins. Progesterone is then assayed by using an antiserum to a progesterone 11..cap alpha..-hemisuccinyl conjugate and the radioligand /sup 125/I-labeled progesterone 11..cap alpha..-glucuronyl tyramine, with separation by double-antibody techniques. Direct assays with either displacing agent gave good analytical recovery of progesterone added to human serum, and progesterone values for patients' specimens correlated well (r > 0.96)more » with results of assays involving extraction of serum. Precision was similar with each displacing agent over the working range 2.5-100 nmol/L and superior to that of extraction assays. We conclude that these direct assays of progesterone are analytically valid and more robust, precise, and technically convenient than many conventional methods involving extraction of serum.« less

  3. Stability of zinc stearate under alpha irradiation in the manufacturing process of SFR nuclear fuels

    NASA Astrophysics Data System (ADS)

    Gracia, J.; Vermeulen, J.; Baux, D.; Sauvage, T.; Venault, L.; Audubert, F.; Colin, X.

    2018-03-01

    The manufacture of new fuels for sodium-cooled fast reactors (SFRs) will involve powders derived from recycling existing fuels in order to keep on producing electricity while saving natural resources and reducing the amount of waste produced by spent MOX fuels. Using recycled plutonium in this way will significantly increase the amount of 238Pu, a high energy alpha emitter, in the powders. The process of shaping powders by pressing requires the use of a solid lubricant, zinc stearate, to produce pellets with no defects compliant with the standards. The purpose of this study is to determine the impact of alpha radiolysis on this additive and its lubrication properties. Experiments were conducted on samples in contact with PuO2, as well as under external helium ion beam irradiation, in order to define the kinetics of radiolytic gas generation. The yield results relating to the formation of these gases (G0) show that the alpha radiation of plutonium can be simulated using external helium ion beam irradiation. The isotopic composition of plutonium has little impact on the yield. However, an increased yield was globally observed with increasing the mean linear energy transfer (LET). A radiolytic degradation process is proposed.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hall, J.; Richard, P.; Gray, T.J.

    The systematics of single and double K-shell-vacancy production in titanium has been investigated in the limit of zero target thickness (approx.1 ..mu..g/cm/sup 2/) for incident C, N, O, F, Mg, Al, Si, S, and Cl ions over a maximum energy range of 0.5 to 6.5 MeV/amu. This corresponds to collision systems with 0.27< or =Z/sub 1//Z/sub 2/< or =0.77 and 0.24< or =v/sub 1//vK< or =0.85, where v/sub 1/ is the projectile nuclear velocity and vK is the mean velocity of an electron in the target K shell. The present work is divided into four major sections. (1) Single K-shell-vacancymore » production has been investigated by measuring K..cap alpha.. and K..beta.. p satellite x-ray-production cross sections for projectiles incident with no K-shell vacancies. For incident ions with Z/sub 1/> or =9, the contribution due to electron-transfer processes from the target K shell to outer shells of the projectile has also been noted. (2) Single K-shell--to--K-shell electron-transfer cross sections have been obtained indirectly by the measuring of the enhancement in the Ti K x-ray production cross section for bare incident projectiles over ions incident with no initial K-shell vacancies. (3) Double K-vacancy production has been investigated by measuring the K..cap alpha.. hypersatellite intensity in ratio to the total K..cap alpha.. intensity. (4) Double K-shell--to--K-shell electron-transfer cross sections have been obtained indirectly with the use of a procedure similar to that used for single K to K transfer. The measured cross sections have been compared to theoretical models for direct Coulomb ionization and inner-shell electron transfer and have been used to investigate the relative importance of these mechanisms for K-vacancy production in heavy-ion--atom collisions.« less

  5. Absolute configurations of organometallic compounds. III. Structure and absolute configuration of the square-pyramidal complex ((+)/sub 579/-(C/sub 5/H/sub 5/)Mo(CO)/sub 2/(NN*))PF/sub 6/(NN* = Schiff base derived from pyridine-2-carbaldehyde and (S)-(-)-. cap alpha. -phenylethylamine)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bernal, I.; LaPlaca, S.J.; Korp, J.

    The structure of (+)/sub 579/-(eta/sup 5/-C/sub 5/H/sub 5/Mo(CO)/sub 2/(NN*))PF/sub 6/ with NN* = the Schiff base derived from pyridine-2-carbaldehyde and (S)-(--)-..cap alpha..-phenylethylamine was determined using standard single-crystal x-ray diffraction methods. The absolute configuration was determined by refinement of the data using the anomalous scattering contributions of Mo and P to a final R(F) = 0.056 for 2634 independent reflections having I greater than 3 sigma (I). The substance crystallizes in the space group P2/sub 1/2/sub 1/2/sub 1/ with unit cell dimensions of a = 12.249 (4), b = 9.236 (3), and c = 20.692 (9) A and Z = 4more » molecules/unit cell. The square-pyramidal coordination of the Mo atom is defined by two carbonyl carbons and two Schiff base nitrogens occupying the four basal plane sites and the five carbons of the eta/sup 5/-C/sub 5/H/sub 5/ ligand in the axial position. The Mo--ligand distances and the bond lengths and angles within the ligands are normal and compare closely with those of recent structure determinations of comparable precision. The Mo atom is 0.95 A above the plane formed by the four basal plane ligands. The conformation of the (S)-..cap alpha..-phenylethyl group with respect to the ligand plane, defined by the pyridine ring, the imine system, and the Mo atom, is discussed. The configuration at the metal atom in the (+)/sub 579/ isomer is specified as (S). The PF/sub 6//sup -/ anion executes large amplitude torsional motion in the lattice, as is commonly the case for this anion when not hydrogen bonded.« less

  6. Biochemistry of snake venom neurotoxins and their application to the study of synapse. [Neurotoxins isolated from venom of the Formosan banded krait

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hanley, M.R.

    1978-11-01

    The crude venom of the Formosan banded krait, Bungarus multicinctus, was separated into eleven lethal protein fractions. Nine fractions were purified to final homogeneous toxins, designated ..cap alpha..-bungarotoxin, ..beta..-bungarotoxin, and toxins 7, 8, 9A, 11, 12, 13, and 14. Three of the toxins, ..cap alpha..-bungarotoxin, 7, and 8, were identified as post-synaptic curarimimetic neurotoxins. The remaining toxins were identified as pre-synaptic neurotoxins. ..cap alpha..-Bungarotoxin, toxin 7, and toxin 8 are all highly stable basic polypeptides of approx. 8000 daltons molecular weight. The pre-synaptic toxins fell into two structural groups: toxin 9A and 14 which were single basic chains of approx.more » 14,000 daltons, and ..beta..-bungarotoxin, and toxins 11 thru 13 which were composed of two chains of approx. 8000 and approx. 13,000 daltons covalently linked by disulfides. All the pre-synaptic neurotoxins were shown to have intrinsic calcium-dependent phospholipase A activities. Under certain conditions, intact synaptic membranes were hydrolyzed more rapidly than protein-free extracted synaptic-lipid liposomes which, in turn, were hydrolyzed more rapidly than any other tested liposomes. It was speculated that cell-surface arrays of phosphatidyl serine/glycolipids created high affinity target sites for ..beta..-bungarotoxin. Single-chain toxins were found to be qualitatively different from the two-chain toxins in their ability to block the functioning of acetylcholine receptors, and were quantitatively different in their enzymatic and membrane disruptive activities. ..beta..-Bungarotoxin was shown to be an extremely potent neuronal lesioning agent. There was no apparent selectivity for cholinergic over non-cholinergic neurons, nor for nerve terminals over cell bodies. It was suggested that ..beta..-bungarotoxin can be considered a useful new histological tool, which may exhibit some regional selectivity.« less

  7. Cold Atmospheric Plasma (CAP) Changes Gene Expression of Key Molecules of the Wound Healing Machinery and Improves Wound Healing In Vitro and In Vivo

    PubMed Central

    Arndt, Stephanie; Unger, Petra; Wacker, Eva; Shimizu, Tetsuji; Heinlin, Julia; Li, Yang-Fang; Thomas, Hubertus M.; Morfill, Gregor E.; Zimmermann, Julia L.

    2013-01-01

    Cold atmospheric plasma (CAP) has the potential to interact with tissue or cells leading to fast, painless and efficient disinfection and furthermore has positive effects on wound healing and tissue regeneration. For clinical implementation it is necessary to examine how CAP improves wound healing and which molecular changes occur after the CAP treatment. In the present study we used the second generation MicroPlaSter ß® in analogy to the current clinical standard (2 min treatment time) in order to determine molecular changes induced by CAP using in vitro cell culture studies with human fibroblasts and an in vivo mouse skin wound healing model. Our in vitro analysis revealed that the CAP treatment induces the expression of important key genes crucial for the wound healing response like IL-6, IL-8, MCP-1, TGF-ß1, TGF-ß2, and promotes the production of collagen type I and alpha-SMA. Scratch wound healing assays showed improved cell migration, whereas cell proliferation analyzed by XTT method, and the apoptotic machinery analyzed by protein array technology, was not altered by CAP in dermal fibroblasts. An in vivo wound healing model confirmed that the CAP treatment affects above mentioned genes involved in wound healing, tissue injury and repair. Additionally, we observed that the CAP treatment improves wound healing in mice, no relevant side effects were detected. We suggest that improved wound healing might be due to the activation of a specified panel of cytokines and growth factors by CAP. In summary, our in vitro human and in vivo animal data suggest that the 2 min treatment with the MicroPlaSter ß® is an effective technique for activating wound healing relevant molecules in dermal fibroblasts leading to improved wound healing, whereas the mechanisms which contribute to these observed effects have to be further investigated. PMID:24265766

  8. Measurements of Lyman-Alpha Escape From HST Far-UV Spectral SNAP Survey of 33 Starforming Galaxies: Initial Results

    NASA Astrophysics Data System (ADS)

    Redwine, Keith

    2018-01-01

    This thesis will describe and analyze far-UV spectra from nearby starforming galaxies to investigate how line features like the hydrogen Lyman-alpha (Lyα) line at 1216 Å are related to the local properties of the host galaxy. It has been suggested that Lyα can be used as a proxy for the escape of Lyman continuum (LyC) radiation, the escape of of which from bright regions of galaxies is of particular interest. Most notably, the reionization epoch of neutral atomic hydrogen in the universe over a redshift range from z∼6 to z∼12, was highly dependent on the flux of ionizing LyC photons in the interstellar and intergalactic media. Expanding our understanding of the dynamics of the Lyα escape fraction (fLyα) from the local environment of its emission could be key to determining a total LyC escape fraction (fLyC) across all morphologies of galaxies. The wide range of Lyα emitters and absorbors (occasionally both) of this Cycle 22 SNAP survey observed by the Cosmic Origins Spectrograph (COS) onboard Hubble Space Telescope (HST) provides a unique look at far-UV spectra in candidate LyC emitters. Lyα profiles are easily observable in short exposures, and line features discernable in the low-resolution G140L mode can inform and guide future observations by COS or other FUV spectroscopy.

  9. The therapeutic potential of polymersomes loaded with 225Ac evaluated in 2D and 3D in vitro glioma models.

    PubMed

    de Kruijff, R M; van der Meer, A J G M; Windmeijer, C A A; Kouwenberg, J J M; Morgenstern, A; Bruchertseifer, F; Sminia, P; Denkova, A G

    2018-06-01

    Alpha emitters have great potential in targeted tumour therapy, especially in destroying micrometastases, due to their high linear energy transfer (LET). To prevent toxicity caused by recoiled daughter atoms in healthy tissue, alpha emitters like 225 Ac can be encapsulated in polymeric nanocarriers (polymersomes), which are capable of retaining the daughter atoms to a large degree. In the translation to a (pre-)clinical setting, it is essential to evaluate their therapeutic potential. As multicellular tumour spheroids mimic a tumour microenvironment more closely than a two-dimensional cellular monolayer, this study has focussed on the interaction of the polymersomes with U87 human glioma spheroids. We have found that polymersomes distribute themselves throughout the spheroid after 4 days which, considering the long half-life of 225 Ac (9.9 d) (Vaidyanathan and Zalutsky, 1996), allows for irradiation of the entire spheroid. A decrease in spheroidal growth has been observed upon the addition of only 0.1 kBq 225 Ac, an effect which was more pronounced for the 225 Ac in polymersomes than when only coupled to DTPA. At higher activities (5 kBq), the spheroids have been found to be destroyed completely after two days. We have thus demonstrated that 225 Ac containing polymersomes effectively inhibit tumour spheroid growth, making them very promising candidates for future in vivo testing. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Evaluation of commercially supplied silver coated Teflon for spacecraft temperature control usage

    NASA Technical Reports Server (NTRS)

    Heaney, J. B.

    1974-01-01

    A series of tests are described which were performed to evaluate the acceptability of a commercially supplied silver backed teflon thermal control coating relative to teflon previously coated at GSFC. Optical measurements made on numerous samples indicate that the commercial material possesses an average solar absorptance of 0.085, an emittance of 0.76 and an average alpha/epsilon equal to 0.112, all of which are equivalent to the GSFC coated teflon. The emittance of the protective inconel backing was found to be 0.037. The coating is shown to have good adhesion at the Ag-teflon interface and exposure to UV irradiation uncovered no coating irregularities. Temperature cycling over the range -135 C to +200 C produced crazing in the evaporated Ag layer as expected but no delamination was observed. The suitability of Mystik no. 7366 and 3M no. 467 adhesives as bonding agents for the metallized polymer is demonstrated. Various problems associated with production reproducibility and selection of a proper bonding process are discussed.

  11. 1988 environmental monitoring report, Sandia National Laboratories, Albuquerque, New Mexico

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Millard, G.; Yeager, G.; Phelan, J.

    1989-05-01

    Sandia National Laboratories (SNL), Albuquerque is located south of Albuquerque on Kirtland Air Force Base. Because radionuclides are potentially released in small quantities from its research activities, SNL, Albuquerque has a continuing environmental monitoring program which analyzes for cesium-137, tritium, uranium, alpha emitters, and beta emitters in water, soil, air, and vegetation. A total of 5.23 curies of argon-41 were released as a result of SNL, Albuquerque operations in 1988. The albuquerque population received an estimated 0.04 person-rem from airborne radioactive releases, whereas it received greater than 44,500 person-rem from naturally occurring radionuclides. A nonradioactive effluent monitoring program at SNL,more » Albuquerque includes groundwater, stormwater and sewage monitoring. Results indicate that the groundwater has not been impacted by the chemical waste landfill. Preliminary testing of stormwater showed that no pollutants were above minimum detectable levels. A program to investigate potential remedial action sites has been started. 47 refs., 12 figs., 19 tabs.« less

  12. Time-resolved spectroscopy of dye-labeled photoactive yellow protein suggests a pathway of light-induced structural changes in the N-terminal cap.

    PubMed

    Hoersch, Daniel; Otto, Harald; Cusanovich, Michael A; Heyn, Maarten P

    2009-07-14

    The photoreceptor PYP responds to light activation with global conformational changes. These changes are mainly located in the N-terminal cap of the protein, which is approximately 20 A away from the chromophore binding pocket and separated from it by the central beta-sheet. The question of the propagation of the structural change across the central beta-sheet is of general interest for the superfamily of PAS domain proteins, for which PYP is the structural prototype. Here we measured the kinetics of the structural changes in the N-terminal cap by transient absorption spectroscopy on the ns to second timescale. For this purpose the cysteine mutants A5C and N13C were prepared and labeled with thiol reactive 5-iodoacetamidofluorescein (IAF). A5 is located close to the N-terminus, while N13 is part of helix alpha1 near the functionally important salt bridge E12-K110 between the N-terminal cap and the central anti-parallel beta-sheet. The absorption spectrum of the dye is sensitive to its environment, and serves as a sensor for conformational changes near the labeling site. In both labeled mutants light activation results in a transient red-shift of the fluorescein absorption spectrum. To correlate the conformational changes with the photocycle intermediates of the protein, we compared the kinetics of the transient absorption signal of the dye with that of the p-hydroxycinnamoyl chromophore. While the structural change near A5 is synchronized with the rise of the I(2) intermediate, which is formed in approximately 200 mus, the change near N13 is delayed and rises with the next intermediate I(2)', which forms in approximately 2 ms. This indicates that different parts of the N-terminal cap respond to light activation with different kinetics. For the signaling pathway of photoactive yellow protein we propose a model in which the structural signal propagates from the chromophore binding pocket across the central beta-sheet via the N-terminal region to helix alpha1, resulting in a large change in the protein conformation.

  13. L-selectin-carbohydrate interactions: relevant modifications of the Lewis x trisaccharide.

    PubMed

    Sanders, W J; Katsumoto, T R; Bertozzi, C R; Rosen, S D; Kiessling, L L

    1996-11-26

    Protein-carbohydrate interactions are known to mediate cell-cell recognition and adhesion events. Specifically, three carbohydrate binding proteins termed selectins (E-, P-, and L-selectin) have been shown to be essential for leukocyte rolling along the vascular endothelium, the first step in the recruitment of leukocytes from the blood into inflammatory sites or into secondary lymphoid organs. Although this phenomenon is well-established, little is known about the molecular-level interactions on which it depends. All three selectins recognize sulfated and sialylated derivatives of the Lewis x [Le(x):Gal beta 1-->4(Fuc alpha 1-->3)GlcNAc] and Lewis a [Le(a): Gal beta 1-->3(Fuc alpha 1-->4)GlcNAc] trisaccharide cores with affinities in the millimolar range, and it is believed that variants of these structures are the carbohydrate determinants of selectin recognition. Recently it was shown that the mucin GlyCAM-1, a secreted physiological ligand for L-selectin, is capped with sulfated derivatives of sialyl Lewis x [sLe(x): Sia alpha 2-->3Gal beta 1-->4(Fuc alpha 1-->3)GlcNAc] and that sulfation is required for the high-affinity interaction between GlyCAM-1 and L-selectin. To elucidate the important sites of sulfation on Le(x) with respect to L-selectin recognition, we have synthesized six sulfated Le(x) analogs and determined their abilities to block binding of a recombinant L-selectin-Ig chimera to immobilized GlyCAM-1. Our results suggest that 6-sulfo sLe(x) binds to L-selectin with higher affinity than does sLe(x) or 6'-sulfo sLe(x) and that sulfation of sLe(x) capping groups on GlyCAM-1 at the 6-position is important for L-selectin recognition.

  14. Hit rates and radiation doses to nuclei of bone lining cells from alpha-particle-emitting radionuclides

    NASA Technical Reports Server (NTRS)

    Polig, E.; Jee, W. S.; Kruglikov, I. L.

    1992-01-01

    Factors relating the local concentration of a bone-seeking alpha-particle emitter to the mean hit rate have been determined for nuclei of bone lining cells using a Monte Carlo procedure. Cell nuclei were approximated by oblate spheroids with dimensions and location taken from a previous histomorphometric study. The Monte Carlo simulation is applicable for planar and diffuse labels at plane or cylindrical bone surfaces. Additionally, the mean nuclear dose per hit, the dose mean per hit, the mean track segment length and its second moment, the percentage of stoppers, and the frequency distribution of the dose have been determined. Some basic features of the hit statistics for bone lining cells have been outlined, and the consequences of existing standards of radiation protection with regard to the hit frequency to cell nuclei are discussed.

  15. Mo(CO)/sub 6/-promoted reductive cleavage of the carbon-sulfur bond

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luh, T.Y.; Wong, C.S.

    1985-12-13

    In order to study the reductive cleavage of carbon-sulfur bonds by Mo(CO/sub 6/, various organosulfur compounds are reacted with Mo(CO)/sub 6/ in THF. Results of these experiments demonstrate that benzylic-, aryl-, or ..cap alpha..-acyl-activated carbon-sulfur bonds are reduced by treatment with Mo(CO)/sub 6/. 1 table.

  16. Alpha emitter radium-223 and survival in metastatic prostate cancer.

    PubMed

    Parker, C; Nilsson, S; Heinrich, D; Helle, S I; O'Sullivan, J M; Fosså, S D; Chodacki, A; Wiechno, P; Logue, J; Seke, M; Widmark, A; Johannessen, D C; Hoskin, P; Bottomley, D; James, N D; Solberg, A; Syndikus, I; Kliment, J; Wedel, S; Boehmer, S; Dall'Oglio, M; Franzén, L; Coleman, R; Vogelzang, N J; O'Bryan-Tear, C G; Staudacher, K; Garcia-Vargas, J; Shan, M; Bruland, Ø S; Sartor, O

    2013-07-18

    Radium-223 dichloride (radium-223), an alpha emitter, selectively targets bone metastases with alpha particles. We assessed the efficacy and safety of radium-223 as compared with placebo, in addition to the best standard of care, in men with castration-resistant prostate cancer and bone metastases. In our phase 3, randomized, double-blind, placebo-controlled study, we randomly assigned 921 patients who had received, were not eligible to receive, or declined docetaxel, in a 2:1 ratio, to receive six injections of radium-223 (at a dose of 50 kBq per kilogram of body weight intravenously) or matching placebo; one injection was administered every 4 weeks. In addition, all patients received the best standard of care. The primary end point was overall survival. The main secondary efficacy end points included time to the first symptomatic skeletal event and various biochemical end points. A prespecified interim analysis, conducted when 314 deaths had occurred, assessed the effect of radium-223 versus placebo on survival. An updated analysis, when 528 deaths had occurred, was performed before crossover from placebo to radium-223. At the interim analysis, which involved 809 patients, radium-223, as compared with placebo, significantly improved overall survival (median, 14.0 months vs. 11.2 months; hazard ratio, 0.70; 95% confidence interval [CI], 0.55 to 0.88; two-sided P=0.002). The updated analysis involving 921 patients confirmed the radium-223 survival benefit (median, 14.9 months vs. 11.3 months; hazard ratio, 0.70; 95% CI, 0.58 to 0.83; P<0.001). Assessments of all main secondary efficacy end points also showed a benefit of radium-233 as compared with placebo. Radium-223 was associated with low myelosuppression rates and fewer adverse events. In this study, which was terminated for efficacy at the prespecified interim analysis, radium-223 improved overall survival. (Funded by Algeta and Bayer HealthCare Pharmaceuticals; ALSYMPCA ClinicalTrials.gov number, NCT00699751.).

  17. Quantitative single-particle digital autoradiography with α-particle emitters for targeted radionuclide therapy using the iQID camera

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, Brian W., E-mail: brian.miller@pnnl.gov; Frost, Sofia H. L.; Frayo, Shani L.

    2015-07-15

    Purpose: Alpha-emitting radionuclides exhibit a potential advantage for cancer treatments because they release large amounts of ionizing energy over a few cell diameters (50–80 μm), causing localized, irreparable double-strand DNA breaks that lead to cell death. Radioimmunotherapy (RIT) approaches using monoclonal antibodies labeled with α emitters may thus inactivate targeted cells with minimal radiation damage to surrounding tissues. Tools are needed to visualize and quantify the radioactivity distribution and absorbed doses to targeted and nontargeted cells for accurate dosimetry of all treatment regimens utilizing α particles, including RIT and others (e.g., Ra-223), especially for organs and tumors with heterogeneous radionuclidemore » distributions. The aim of this study was to evaluate and characterize a novel single-particle digital autoradiography imager, the ionizing-radiation quantum imaging detector (iQID) camera, for use in α-RIT experiments. Methods: The iQID camera is a scintillator-based radiation detection system that images and identifies charged-particle and gamma-ray/x-ray emissions spatially and temporally on an event-by-event basis. It employs CCD-CMOS cameras and high-performance computing hardware for real-time imaging and activity quantification of tissue sections, approaching cellular resolutions. In this work, the authors evaluated its characteristics for α-particle imaging, including measurements of intrinsic detector spatial resolutions and background count rates at various detector configurations and quantification of activity distributions. The technique was assessed for quantitative imaging of astatine-211 ({sup 211}At) activity distributions in cryosections of murine and canine tissue samples. Results: The highest spatial resolution was measured at ∼20 μm full width at half maximum and the α-particle background was measured at a rate as low as (2.6 ± 0.5) × 10{sup −4} cpm/cm{sup 2} (40 mm diameter detector area). Simultaneous imaging of multiple tissue sections was performed using a large-area iQID configuration (ø 11.5 cm). Estimation of the {sup 211}At activity distribution was demonstrated at mBq/μg-levels. Conclusions: Single-particle digital autoradiography of α emitters has advantages over traditional film-based autoradiographic techniques that use phosphor screens, in terms of spatial resolution, sensitivity, and activity quantification capability. The system features and characterization results presented in this study show that the iQID is a promising technology for microdosimetry, because it provides necessary information for interpreting alpha-RIT outcomes and for predicting the therapeutic efficacy of cell-targeted approaches using α emitters.« less

  18. Quantitative single-particle digital autoradiography with α-particle emitters for targeted radionuclide therapy using the iQID camera.

    PubMed

    Miller, Brian W; Frost, Sofia H L; Frayo, Shani L; Kenoyer, Aimee L; Santos, Erlinda; Jones, Jon C; Green, Damian J; Hamlin, Donald K; Wilbur, D Scott; Fisher, Darrell R; Orozco, Johnnie J; Press, Oliver W; Pagel, John M; Sandmaier, Brenda M

    2015-07-01

    Alpha-emitting radionuclides exhibit a potential advantage for cancer treatments because they release large amounts of ionizing energy over a few cell diameters (50-80 μm), causing localized, irreparable double-strand DNA breaks that lead to cell death. Radioimmunotherapy (RIT) approaches using monoclonal antibodies labeled with α emitters may thus inactivate targeted cells with minimal radiation damage to surrounding tissues. Tools are needed to visualize and quantify the radioactivity distribution and absorbed doses to targeted and nontargeted cells for accurate dosimetry of all treatment regimens utilizing α particles, including RIT and others (e.g., Ra-223), especially for organs and tumors with heterogeneous radionuclide distributions. The aim of this study was to evaluate and characterize a novel single-particle digital autoradiography imager, the ionizing-radiation quantum imaging detector (iQID) camera, for use in α-RIT experiments. The iQID camera is a scintillator-based radiation detection system that images and identifies charged-particle and gamma-ray/x-ray emissions spatially and temporally on an event-by-event basis. It employs CCD-CMOS cameras and high-performance computing hardware for real-time imaging and activity quantification of tissue sections, approaching cellular resolutions. In this work, the authors evaluated its characteristics for α-particle imaging, including measurements of intrinsic detector spatial resolutions and background count rates at various detector configurations and quantification of activity distributions. The technique was assessed for quantitative imaging of astatine-211 ((211)At) activity distributions in cryosections of murine and canine tissue samples. The highest spatial resolution was measured at ∼20 μm full width at half maximum and the α-particle background was measured at a rate as low as (2.6 ± 0.5) × 10(-4) cpm/cm(2) (40 mm diameter detector area). Simultaneous imaging of multiple tissue sections was performed using a large-area iQID configuration (ø 11.5 cm). Estimation of the (211)At activity distribution was demonstrated at mBq/μg-levels. Single-particle digital autoradiography of α emitters has advantages over traditional film-based autoradiographic techniques that use phosphor screens, in terms of spatial resolution, sensitivity, and activity quantification capability. The system features and characterization results presented in this study show that the iQID is a promising technology for microdosimetry, because it provides necessary information for interpreting alpha-RIT outcomes and for predicting the therapeutic efficacy of cell-targeted approaches using α emitters.

  19. Inhibition of ribosome recruitment induces stress granule formation independently of eukaryotic initiation factor 2alpha phosphorylation.

    PubMed

    Mazroui, Rachid; Sukarieh, Rami; Bordeleau, Marie-Eve; Kaufman, Randal J; Northcote, Peter; Tanaka, Junichi; Gallouzi, Imed; Pelletier, Jerry

    2006-10-01

    Cytoplasmic aggregates known as stress granules (SGs) arise as a consequence of cellular stress and contain stalled translation preinitiation complexes. These foci are thought to serve as sites of mRNA storage or triage during the cell stress response. SG formation has been shown to require induction of eukaryotic initiation factor (eIF)2alpha phosphorylation. Herein, we investigate the potential role of other initiation factors in this process and demonstrate that interfering with eIF4A activity, an RNA helicase required for the ribosome recruitment phase of translation initiation, induces SG formation and that this event is not dependent on eIF2alpha phosphorylation. We also show that inhibition of eIF4A activity does not impair the ability of eIF2alpha to be phosphorylated under stress conditions. Furthermore, we observed SG assembly upon inhibition of cap-dependent translation after poliovirus infection. We propose that SG modeling can occur via both eIF2alpha phosphorylation-dependent and -independent pathways that target translation initiation.

  20. Bis(carbazol-9-ylphenyl)aniline end-capped oligoarylenes as solution-processed nondoped emitters for full-emission color tuning organic light-emitting diodes.

    PubMed

    Khanasa, Tanika; Prachumrak, Narid; Rattanawan, Rattanawaree; Jungsuttiwong, Siriporn; Keawin, Tinnagon; Sudyoadsuk, Taweesak; Tuntulani, Thawatchai; Promarak, Vinich

    2013-07-05

    A series of bis(3,6-di-tert-butylcarbazol-9-ylphenyl)aniline end-capped oligoarylenes, BCPA-Ars, are synthesized by double palladium-catalyzed cross-coupling reactions. By using this bis(carbazol-9-yl)triphenylamine moiety as an end-cap, we are able to reduce the crystallization and retain the high-emission ability of these planar fluorescent oligoarylene cores in the solid state, as well as improve the amorphous stability and solubility of the materials. The results of optical and electrochemical studies show that their HOMOs, LUMOs, and energy gaps can be easily modified or fine-tuned by either varying the degree of π-conjugation or using electron affinities of the aryl cores which include fluorene, oligothiophenes, 2,1,3-benzothiadiazole, 4,7-diphenyl-4-yl-2,1,3-benzothiadiazole, and 4,7-dithien-2-yl-2,1,3-benzothiadiazole. As a result, their emission spectra measured in solution and thin films can cover the full UV-vis spectrum (426-644 nm). Remarkably, solution-processed nondoped BCPA-Ars-based OLEDs could show moderate to excellent device performance with emission colors spanning the whole visible spectrum (deep blue to red). Particularly, the RGB (red, green, blue) OLEDs exhibit good color purity close to the pure RGB colors. This report offers a practical approach for both decorating the highly efficient but planar fluorophores and tuning their emission colors to be suitable for applications in nondoped and solution-processable full-color emission OLEDs.

  1. The BetaCage, an ultra-sensitive screener for surface contamination

    NASA Astrophysics Data System (ADS)

    Bunker, R.; Ahmed, Z.; Bowles, M. A.; Golwala, S. R.; Grant, D. R.; Kos, M.; Nelson, R. H.; Schnee, R. W.; Rider, A.; Wang, B.; Zahn, A.

    2013-08-01

    Material screening for identifying low-energy electron emitters and alpha-decaying isotopes is now a prerequisite for rare-event searches (e.g., dark-matter direct detection and neutrinoless double-beta decay) for which surface radiocon-tamination has become an increasingly important background. The BetaCage, a gaseous neon time-projection chamber, is a proposed ultra-sensitive (and nondestructive) screener for alpha-and beta-emitting surface contaminants to which existing screening facilities are insufficiently sensitive. Sensitivity goals are 0.1 betas keV-1 m-2 day-1 and 0.1 alphas m-2 day-1, with the former limited by Compton scattering of photons in the screening samples and (thanks to tracking) the latter expected to be signal-limited; radioassays and simulations indicate backgrounds from detector materials and radon daughters should be subdominant. We report on details of the background simulations and detector design that provide the discrimination, shielding, and radiopurity necessary to reach our sensitivity goals for a chamber with a 95 × 95 cm2 sample area positioned below a 40 cm drift region and monitored by crisscrossed anode and cathode planes consisting of 151 wires each.

  2. Alpha3, a transposable element that promotes host sexual reproduction.

    PubMed

    Barsoum, Emad; Martinez, Paula; Aström, Stefan U

    2010-01-01

    Theoretical models predict that selfish DNA elements require host sex to persist in a population. Therefore, a transposon that induces sex would strongly favor its own spread. We demonstrate that a protein homologous to transposases, called alpha3, was essential for mating type switch in Kluyveromyces lactis. Mutational analysis showed that amino acids conserved among transposases were essential for its function. During switching, sequences in the 5' and 3' flanking regions of the alpha3 gene were joined, forming a DNA circle, showing that alpha3 mobilized from the genome. The sequences encompassing the alpha3 gene circle junctions in the mating type alpha (MATalpha) locus were essential for switching from MATalpha to MATa, suggesting that alpha3 mobilization was a coupled event. Switching also required a DNA-binding protein, Mating type switch 1 (Mts1), whose binding sites in MATalpha were important. Expression of Mts1 was repressed in MATa/MATalpha diploids and by nutrients, limiting switching to haploids in low-nutrient conditions. A hairpin-capped DNA double-strand break (DSB) was observed in the MATa locus in mre11 mutant strains, indicating that mating type switch was induced by MAT-specific DSBs. This study provides empirical evidence for selfish DNA promoting host sexual reproduction by mediating mating type switch.

  3. Comment on de-averaged back-angle heavy-ion elastic scattering excitation functions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hussein, M.S.; Canto, L.F.; Donangelo, R.

    1984-06-01

    It is suggested that the de-averaged 180/sup 0/ excitation function of /sup 16/O+ /sup 28/Si, recently considered by Frahn and Kaufmann, is strongly model dependent. Within a multistep ..cap alpha..-transfer description of the back-angle anomaly, we obtain a de-averaged 180/sup 0/ excitation function that exhibits a more regular gross structure.

  4. Doppler-broadening measurements of x-ray lines for determination of the ion temperature in tokamak plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bitter, M.; von Goeler, S.; Horton, R.

    1979-01-29

    Ion-temperature results are deduced from Doppler-broadening measurements of the K..cap alpha.. (1s-2p) resonance line emitted from heliumlike iron impurity ions in the hot central core of PLT (Princeton Large Torus) tokamak discharges. The measurements were performed using a high-resolution Bragg-crystal spectrometer with a multiwire proportional counter.

  5. Structural phase transitions in GaAs to 108 GPa

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weir, S.T.; Vohra, Y.K.; Vanderborgh, C.A.

    1989-01-15

    The III-V compound GaAs was studied using energy-dispersive x-ray diffraction with a synchro- tron source up to a pressure of 108 GPa. When the pressure was increased to 16.6 GPa, the GaAs sample transformed from the zinc-blende structure to an orthorhombic structure (GaAs(II)), space group Pmm2, consisting of a primitive orthorhombic lattice with a basis of (0,0,0) and (0,(1/2,..cap alpha..), where ..cap alpha.. = 0.35. Upon a further increase of pressure to 24 +- 1 GPa, GaAs(II) transformed to another orthorhombic structure (GaAs(III)), space group Imm2, consisting of a body-centered orthorhombic lattice with a basis of (0,0,0) and (0, (1/2,..delta..),more » where ..delta.. is 0.425 at 28.1 GPa. With increasing pressure, ..delta.. approached (1/2 and the GaAs(III) structure gradually assumed the symmetry of the simple hexagonal structure. The transition to the simple hexagonal structure (GaAs(IV)) was completed in the vicinity of 60--80 GPa. The structure remains simple hexagonal up to at least 108 GPa, the highest pressure reached in this study.« less

  6. Use of antibodies specific to defined regions of scorpion. cap alpha. -toxin to study its interaction with its receptor site on the sodium channel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ayeb, M.E.; Bahraoui, E.M.; Granier, C.

    1986-10-21

    Five antibody populations selected by immunoaffinity chromatography for the specificity toward various regions of toxin II of the scorpion Androctonus australis Hector were used to probe the interaction of this protein with its receptor site on the sodium channel. These studies indicate that two antigenic sites, one located around the disulfide bridge 12-63 and one encompassing residues 50-59, are involved in the molecular mechanisms of toxicity neutralization. Fab fragments specific to the region around disulfide bridge 12-63 inhibit binding of the /sup 125/I-labeled toxin to its receptor site. Also, these two antigenic regions are inaccessible to the antibodies when themore » toxin is bound to its receptor site. In contrast, the two other antigenic sites encompassing the only ..cap alpha..-helix region (residues 23-32) and a ..beta..-turn structure (residues 32-35) are accessible to the respective antibodies when the toxin is bound to its receptor. Together, these data support the recent proposal that a region made of residues that are conserved in the scorpion toxin family is involved in the binding of the toxin to the receptor.« less

  7. Survey of the (. cap alpha. ,/sup 2/He) reaction on 1p- and 2s1d-shell nuclei

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jahn, R.; Stahel, D.P.; Wozniak, G.J.

    A /sup 2/He detection system has been developed and used to investigate the (..cap alpha..,/sup 2/He) reaction at bombarding energies of 55 and 65 MeV on targets of /sup 12/C, /sup 13/C, /sup 14/N, /sup 15/N, /sup 16/O, /sup 18/O, /sup 20/Ne, /sup 22/Ne, /sup 24/Mg, /sup 26/Mg, /sup 28/Si, /sup 29/Si, /sup 32/S, /sup 36/Ar, /sup 38/Ar, and /sup 40/Ca. Preferential population of two-neutron states with dominant (d/sub 5/2/)/sup 2//sub 4/, (d/sub 3/2/f/sub 7/2/)/sub 5/, and (f/sub 7/2/)/sup 2//sub 6/ character was observed. A linear A dependence of the binding energies of the J/sup ..pi../ = 5/sup -/ andmore » 6/sup +/ states was obtained. This systematic behavior is well described by the Bansal-French model, using the parameters a = - 0.30 MeV and b = 2.6 MeV. Simple shell-model calculations for the 2n configurations are in good agreement with the experimental data.« less

  8. Multiconfiguration resonating-group theory of the seven-nucleon system with realistic cluster wave functions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fujiwara, Y.; Tang, Y.C.

    1985-02-01

    The properties of the seven-nucleon system are examined with a multiconfiguration and multi- channel resonating-group calculation. The cluster internal functions employed explain the charge-form-factor data over a wide range of q/sup 2/ and satisfy the variational stability condition quite well. The model space used is spanned by /sup 3/H+..cap alpha.., n+ /sup 6/Li, n+ /sup 6/Li(, and d+ /sup 5/He cluster configurations. The result shows that the specific distortion of the /sup 3/H+..cap alpha.. system is quite significant. With our multiconfiguration calculation, the ground-state energy is improved by more than 1 MeV. The calculated level spectrum agrees well with themore » level spectrum empirically determined. The energy positions of both natural-parity and unnatural-parity levels are reasonably explained. In addition, we find that, because of centrifugal-barrier effects, the aligned configuration generally makes the most sig- nificant contribution. The characteristics of nucleon-exchange terms are also briefly examined. Here it is found that, at sufficiently high energies where sharp resonance levels do not exist, the essential properties of these terms can already be learned by performing relatively simple single-configuration calculations.« less

  9. Effects of capsaicin in the motor nerve.

    PubMed

    Pettorossi, V E; Bortolami, R; Della Torre, G; Brunetti, O

    1994-08-01

    The injection of capsaicin into the lateral gastrocnemius (LG) muscle of the rat induced an immediate and sustained reduction in the A delta and C components of the compound action potential (CAP) of the LG motor nerve. Conversely, the drug did not immediately affect the CAP wave belonging to fast-conducting fibers or the motor responses to LG nerve stimulation. It seems that capsaicin only affects the group III and IV afferents of LG nerve. However, a week after the injection the capsaicin also altered the motor responses, as shown by the threshold enhancement and amplitude reduction of the muscle twitch and by the decrease of the A alpha-beta CAP components. This late motor impairment was attributed to a central depression following a reduction of capsaicin-sensitive neuron input into the CNS. However, this motor effect was transient since the LG nerve regained the preinjection excitability level in a week and the muscle twitch amplitude reached the control value in a month.

  10. Preparation and characterization of highly water-soluble magnetic Fe3O4 nanoparticles via surface double-layered self-assembly method of sodium alpha-olefin sulfonate

    NASA Astrophysics Data System (ADS)

    Li, Honghong; Qin, Li; Feng, Ying; Hu, Lihua; Zhou, Chunhua

    2015-06-01

    A kind of double-layered self-assembly sodium alpha-olefin sulfonate (AOS) capped Fe3O4 magnetic nanoparticles (Fe3O4-AOS-MN) with highly water-solubility was prepared by a wet co-precipitation method with a pH of 4.8. The resulting Fe3O4-AOS-MN could be dispersed into water to form stable magnetic fluid without other treatments. The result of X-ray diffraction (XRD) indicated that the Fe3O4-AOS-MN maintained original crystalline structure and exhibited a diameter of about 7.5 nm. The iron oxide phase of nanoparticles determined by Raman spectroscopy is Fe3O4. Transmission electron microscopy (TEM) analysis confirmed that the Fe3O4-AOS-MN with spherical morphology were uniformly dispersed in water. FT-IR spectroscopy (FT-IR) and thermo-gravimetric analysis (TGA) verified the successful preparation of Fe3O4-AOS-MN capped with double-layered self-assembled AOS. The corresponding capacities of monolayer chemical absorption and the second-layer self-assembly absorption were respectively 4.07 and 14.71 wt% of Fe3O4-MN, which were much lower than those of other surfactants. Vibrating sample magnetometer (VSM) test result showed Fe3O4-AOS-MN possessed superparamagnetic behavior with the saturation magnetization value of about 44.45 emu/g. The blocking temperature TB of Fe3O4-AOS-MN capped with double-layered AOS is 170 K.

  11. Direct assays of radiation-induced DNA base lesions in mammalian cells: Technical progress report, July 1, 1986--December 1, 1988

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wheeler, K.T. Jr.

    1988-01-01

    Our cesium irradiator was installed in April 1987 and has the capability of irradiating DNA solutions, cells and animals at dose rates from >60 Gy/min to <10/sup /minus/2/ Gy/min. By early summer all of the dosimetry and set-ups were established to perform this research. In may 1987, Dr. Krystyna Lesiak left to return to the National Institutes of Health. However, she has remained a collaborator over the past 1/1/2/ years. She has synthesized a large lot of ..cap alpha..-deoxyadenosine, isolated a large batch of both the R and S isomer of cyclodeoxyadenosine and has capped the ..cap alpha..-deoxyadenonsine for usemore » in a DNA synthesizer that uses phosphoramidite chemistry. In November 1987, Dr. Andrzej Surowiec joined our unit as a Visiting Research Assistant Professor. Dr. Surowiec has a MS degree in electrical engineering and did his Ph.D. in Biophysics studying the conductivity of DNA in dilute solution. He has been performing the helix-coil transition experiments. In November 1987, Dr. Steven Swarts also joined our unit as a Postdoctoral Fellow. He received his Ph.D. from Oakland University under Dr. Michael Sevilla with whom we have a collaboration studying the induction of base damage in hydrated DNA. Dr. Swarts has a strong background in spectroscopy and, therefore, was a key individual for determination of the limitations of the HPLC assays and the establishment of a GC/MS capability equivalent to Dr. M. Dizdaroglu at the National Bureau of Standards. 9 refs., 1 tab.« less

  12. Hydrothermal synthesis of alpha- and beta-HgS nanostructures

    NASA Astrophysics Data System (ADS)

    Galain, Isabel; María, Pérez Barthaburu; Ivana, Aguiar; Laura, Fornaro

    2017-01-01

    We synthesized HgS nanostructures by the hydrothermal method in order to use them as electron acceptors in hybrid organic-inorganic solar cells. We employed different mercury sources (HgO and Hg(CH3COO)2) and polyvinylpyrrolidone (PVP) or hexadecanethiol (HDT) as stabilizing/capping agent for controlling size, crystallinity, morphology and stability of the obtained nanostructures. We also used thiourea as sulfur source, and a temperature of 180 °C during 6 h. Synthesized nanostructures were characterized by powder X-Ray Diffraction, Diffuse Reflectance Infrared Fourier Transform and Transmission Electron Microscopy. When PVP acts as stabilizing agent, the mercury source has influence on the size -but not in morphology- of the beta-HgS obtained nansostructures. HDT has control over nanostructures' size and depending on the relation Hg:HDT, we obtained a mixture of alpha and beta HgS which can be advantageous in the application in solar cells, due their absorption in different spectral regions. The smallest nanostructures obtained have a mean diameter of 20 nm when using HDT as capping agent. Also, we deposited the aforementioned nanostructures onto flat glass substrates by the spin coating technique as a first approach of an active layer of a solar cell. The depositions were characterized by atomic force microscopy. We obtained smaller particle deposition and higher particle density -but a lower area coverage (5%) - in samples with HDT as capping agent. This work presents promising results on nanostructures for future application on hybrid solar cells. Further efforts will be focused on the deposition of organic-inorganic layers.

  13. Treatment of catastrophic antiphospholipid syndrome with defibrotide, a proposed vascular endothelial cell modulator.

    PubMed

    Burcoglu-O'Ral, Arsinur; Erkan, Doruk; Asherson, Ronald

    2002-09-01

    To define at the molecular level the vascular endothelial cell (VEC) injury characteristics of catastrophic antiphospholipid syndrome (CAPS) and to report successful therapeutic use of a VEC modulator, defibrotide. We describe a 55-year-old man with primary APS with an intractable prothrombotic state (CAPS) resistant to combined therapy with heparin, warfarin, aspirin, and dipyridamole. Treatment with defibrotide was conducted in the context of an investigational phase II protocol where the dose was regulated and individualized by disease/patient-specific molecular and clinical markers. The patient entered complete remission with defibrotide treatment. During treatment, dose dependent pharmacological actions of defibrotide and key stress markers for VEC injury were identified. Evidence of defibrotide's polypharmacology included downregulation of cytokines, notably tumor necrosis factor-alpha, as the earliest effect, cellular differentiation of VEC, possibly with direct regulatory effect over cellular genes, and the reversal of platelet consumption and prothrombotic state. Von Willebrand antigen levels were used as the sole marker to guide therapy. This case demonstrates effective remission of CAPS with defibrotide treatment. In contrast to theories that CAPS is triggered by ischemic and thrombotic tissue damage, these data present VEC injury as the primary and representative lesion of CAPS. The pathogenesis may involve concurrent impairment of different VEC functions. Achieving remission may require a polypharmacologic approach, represented here by use of defibrotide.

  14. Characterization of the primary interaction between the mating pheromone, alpha-factor, and its receptor in Saccharomyces cerevisiae

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Raths, S.K.

    1987-01-01

    Alpha-factor is a peptide of thirteen amino acids which is required for mating between the haploid mating types, a and ..cap alpha.., in Saccharomyces cerevisiae. An analogue of alpha-factor, DHP/sup 8/ DHP/sup 11/ Nle/sup 12/ tridecapeptide, was catalytically reduced in the presence of /sup 3/H gas for production of a radiolabeled pheromone suitable for use in binding studies. Incorporation of tritium resulted in /sup 3/H-alpha-factor with high specific activity, purity, biological activity and long shelf-life. Binding studies revealed that alpha-factor interacts with its receptor via a simple, reversible process which obeys the law of mass action. Association and dissociation kineticsmore » indicate values of 2.92 x 10/sup 6/ M/sup /minus/1/ min/sup -1/ for k/sub 1/ and between 4 and 7 x 10/sup /minus/2/ min/sup /minus/1/ for k/sub /minus/1/. Saturation binding studies reveal an equilibrium dissociation constant equal to 2.32 x 10/sup /minus/8/ M which approximate the kinetically-derived K/sub D/ of 2.12 x 10/sup /minus/8/ M. Scatchard and Hill analyses as well as dissociation behavior in the presence of excess unlabeled ligand indicate alpha-factor interacts with a homogeneous population of binding sites which do not interact and exhibit one affinity for the alpha-factor pheromone.« less

  15. Simulation study on beam loss in the alpha bucket regime during SIS-100 proton operation

    NASA Astrophysics Data System (ADS)

    Sorge, S.

    2018-02-01

    Crossing the transition energy γt in synchrotrons for high intensity proton beams requires well tuned jump schemes and is usually accompanied by longitudinal emittance growth. In order to avoid γt crossing during proton operation in the projected SIS-100 synchrotron special high-γt lattice settings have been developed, in order to keep γt above the beam extraction energy. A further advantage of this scheme is the formation of alpha buckets which naturally lead to short proton bunches, required for the foreseen production and storage of antiprotons for the FAIR facility. Special attention is turned on the imperfections of the superconducting SIS-100 magnets because together with the high-γt lattice settings, they could potentially lead to enhanced beam loss. The aim of the present work is to estimate the beam loss by means of particle tracking simulations.

  16. Tailoring Thin Film-Lacquer Coatings for Space Applications

    NASA Technical Reports Server (NTRS)

    Peters, Wanda C.; Harris, George; Miller, Grace; Petro, John

    1998-01-01

    Thin film coatings have the capability of obtaining a wide range of thermal radiative properties, but the development of thin film coatings can sometimes be difficult and costly when trying to achieve highly specular surfaces. Given any space mission's then-nal control requirements, there is often a need for a variation of solar absorptance (alpha(sub s)), emittance (epsilon) and/or highly specular surfaces. The utilization of thin film coatings is one process of choice for meeting challenging thermal control requirements because of its ability to provide a wide variety of alpha(sub s)/epsilon ratios. Thin film coatings' radiative properties can be tailored to meet specific thermal control requirements through the use of different metals and the variation of dielectric layer thickness. Surface coatings can be spectrally selective to enhance radiative coupling and decoupling. The application of lacquer to a surface can also provide suitable specularity for thin film application without the cost and difficulty associated with polishing.

  17. Spectral Energy Distribution Fitting of Hetdex Pilot Survey Ly-alpha Emitters in Cosmos and Goods-N

    NASA Technical Reports Server (NTRS)

    Hagen, Alex; Ciardullo, Robin; Cronwall, Caryl; Acquaviva, Viviana; Bridge, Joanna; Zeimann, Gregory R.; Blanc, Guillermo; Bond, Nicholas; Finkelstein, Steven L.; Song, Mimi; hide

    2014-01-01

    We use broadband photometry extending from the rest-frame UV to the near-IR to fit the individual spectral energy distributions of 63 bright (L(Ly-alpha) greater than 10(exp 43) erg s(exp -1) Ly-alpha emitting galaxies (LAEs) in the redshift range 1.9 less than z less than 3.6. We find that these LAEs are quite heterogeneous, with stellar masses that span over three orders of magnitude, from 7.5 greater than logM/solar mass less than 10.5. Moreover, although most LAEs have small amounts of extinction, some high-mass objects have stellar reddenings as large as E(B - V ) is approximately 0.4. Interestingly, in dusty objects the optical depths for Ly-alpha and the UV continuum are always similar, indicating that Lya photons are not undergoing many scatters before escaping their galaxy. In contrast, the ratio of optical depths in low-reddening systems can vary widely, illustrating the diverse nature of the systems. Finally, we show that in the star-formation-rate-log-mass diagram, our LAEs fall above the "main-sequence" defined by z is approximately 3 continuum selected star-forming galaxies. In this respect, they are similar to submillimeter-selected galaxies, although most LAEs have much lower mass.

  18. From Beamline to Scanner with 225Ac

    NASA Astrophysics Data System (ADS)

    Robertson, Andrew K. H.; Ramogida, Caterina F.; Kunz, Peter; Rodriguez-Rodriguez, Cristina; Schaffer, Paul; Sossi, Vesna

    2016-09-01

    Due to the high linear energy transfer and short range of alpha-radiation, targeted radiation therapy using alpha-emitting pharmaceuticals that successfully target small disease clusters will kill target cells with limited harm to healthy tissue, potentially treating the most aggressive forms of cancer. As the parent of a decay chain with four alpha- and two beta-decays, 225Ac is a promising candidate for such a treatment. However, this requires retention of the entire decay chain at the target site, preventing the creation of freely circulating alpha-emitters that reduce therapeutic effect and increase toxicity to non-target tissues. Two major challenges to 225Ac pharmaceutical development exist: insufficient global supply, and the difficulty of preventing toxicity by retaining the entire decay chain at the target site. While TRIUMF works towards large-scale (C i amounts) production of 225Ac, we already use our Isotope Separation On-Line facility to provide small (< 1 mCi) quantities for in-house chemistry and imaging research that aims to improve and assess 225Ac radiopharmaceutical targeting. This presentation provides an overview of this research program and the journey of 225Ac from the beamline to the scanner. This research is funded by the Natural Sciences and Engineering Research Council of Canada.

  19. Prototype Demonstration of Gamma- Blind Tensioned Metastable Fluid Neutron/Multiplicity/Alpha Detector – Real Time Methods for Advanced Fuel Cycle Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McDeavitt, Sean M.

    The content of this report summarizes a multi-year effort to develop prototype detection equipment using the Tensioned Metastable Fluid Detector (TMFD) technology developed by Taleyarkhan [1]. The context of this development effort was to create new methods for evaluating and developing advanced methods for safeguarding nuclear materials along with instrumentation in various stages of the fuel cycle, especially in material balance areas (MBAs) and during reprocessing of used nuclear fuel. One of the challenges related to the implementation of any type of MBA and/or reprocessing technology (e.g., PUREX or UREX) is the real-time quantification and control of the transuranic (TRU)more » isotopes as they move through the process. Monitoring of higher actinides from their neutron emission (including multiplicity) and alpha signatures during transit in MBAs and in aqueous separations is a critical research area. By providing on-line real-time materials accountability, diversion of the materials becomes much more difficult. The Tensioned Metastable Fluid Detector (TMFD) is a transformational technology that is uniquely capable of both alpha and neutron spectroscopy while being “blind” to the intense gamma field that typically accompanies used fuel – simultaneously with the ability to provide multiplicity information as well [1-3]. The TMFD technology was proven (lab-scale) as part of a 2008 NERI-C program [1-7]. The bulk of this report describes the advancements and demonstrations made in TMFD technology. One final point to present before turning to the TMFD demonstrations is the context for discussing real-time monitoring of SNM. It is useful to review the spectrum of isotopes generated within nuclear fuel during reactor operations. Used nuclear fuel (UNF) from a light water reactor (LWR) contains fission products as well as TRU elements formed through neutron absorption/decay chains. The majority of the fission products are gamma and beta emitters and they represent the more significant hazards from a radiation protection standpoint. However, alpha and neutron emitting uranium and TRU elements represent the more significant safeguards and security concerns. Table 1.1 presents a representative PWR inventory of the uranium and actinide isotopes present in a used fuel assembly. The uranium and actinide isotopes (chiefly the Pu, Am and Cm elements) are all emitters of alpha particles and some of them release significant quantities of neutrons through spontaneous fissions« less

  20. A new genetic factor for root gravitropism in rice (Oryza sativa L.).

    PubMed

    Shi, Jiang-hua; Hao, Xi; Wu, Zhong-chang; Wu, Ping

    2009-10-01

    Root gravitropism is one of the important factors to determine root architecture. To understand the mechanism underlying root gravitropism, we isolated a rice (Xiushui63) mutant defective in root gravitropism, designated as gls1. Vertical sections of root caps revealed that gls1 mutant displayed normal distribution of amyloplast in the columella cells compared with the wild type. The gls1 mutant was less sensitive to 2,4-dichlorophenoxyacetic acid (2,4-D) and alpha-naphthaleneacetic acid (NAA) than the wild type. Genetic analysis indicated that the phenotype of gls1 mutant was caused by a single recessive mutation, which is mapped in a 255-kb region between RM16253 and CAPS1 on the short arm of chromosome 4.

  1. The mean ultraviolet spectrum of a representative sample of faint z ˜ 3 Lyman alpha emitters

    NASA Astrophysics Data System (ADS)

    Nakajima, Kimihiko; Fletcher, Thomas; Ellis, Richard S.; Robertson, Brant E.; Iwata, Ikuru

    2018-06-01

    We discuss the rest-frame ultraviolet (UV) emission line spectra of a large (˜100) sample of low luminosity redshift z ˜ 3.1 Lyman alpha emitters (LAEs) drawn from a Subaru imaging survey in the SSA22 survey field. Our earlier work based on smaller samples indicated that such sources have high [O III]/[O II] line ratios possibly arising from a hard ionizing spectrum that may be typical of similar sources in the reionization era. With optical spectra secured from VLT/VIMOS, we re-examine the nature of the ionizing radiation in a larger sample using the strength of the high ionization diagnostic emission lines of CIII]λ1909, CIVλ1549, HEIIλ1640, and O III]λλ1661, 1666 Å in various stacked subsets. Our analysis confirms earlier suggestions of a correlation between the strength of Ly α and CIII] emission and we find similar trends with broad-band UV luminosity and rest-frame UV colour. Using various diagnostic line ratios and our stellar photoionization models, we determine both the gas phase metallicity and hardness of the ionization spectrum characterized by ξion - the number of Lyman continuum photons per UV luminosity. We confirm our earlier suggestion that ξion is significantly larger for LAEs than for continuum-selected Lyman break galaxies, particularly for those LAEs with the faintest UV luminosities. We briefly discuss the implications for cosmic reionization if the metal-poor intensely star-forming systems studied here are representative examples of those at much higher redshift.

  2. Radiological Assessment for the Removal of Legacy BPA Power Lines that Cross the Hanford Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Millsap, William J.; Brush, Daniel J.

    This paper discusses some radiological field monitoring and assessment methods used to assess the components of an old electrical power transmission line that ran across the Hanford Site between the production reactors area (100 Area) and the chemical processing area (200 Area). This task was complicated by the presence of radon daughters -- both beta and alpha emitters -- residing on the surfaces, particularly on the surfaces of weathered metals and metals that had been electrically-charged. In many cases, these activities were high compared to the DOE Surface Contamination Guidelines, which were used as guides for the assessment. These methodsmore » included the use of the Toulmin model of argument, represented using Toulmin diagrams, to represent the combined force of several strands of evidences, rather than a single measurement of activity, to demonstrate beyond a reasonable doubt that no or very little Hanford activity was present and mixed with the natural activity. A number of forms of evidence were used: the overall chance of Hanford contamination; measurements of removable activity, beta and alpha; 1-minute scaler counts of total surface activity, beta and alpha, using "background makers"; the beta activity to alpha activity ratios; measured contamination on nearby components; NaI gamma spectral measurements to compare uncontaminated and potentially-contaminated spectra, as well as measurements for the sentinel radionuclides, Am- 241 and Cs-137 on conducting wire; comparative statistical analyses; and in-situ measurements of alpha spectra on conducting wire showing that the alpha activity was natural Po-210, as well as to compare uncontaminated and potentially-contaminated spectra.« less

  3. Polariton effects in naphthalene crystals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robinette, Susan Louise

    1977-10-01

    The experimental verification of the two-step nature of energy dissipation of photon energy by a crystal is the subject of this dissertation. The ..cap alpha..(O,O) Davydov component of the lowest energy singlet transition in pure strain-free napthalene single crystals is shown to exhibit an increase in absorption with increasing temperature, due to an increase in polariton damping via polariton-phonon scattering processes. (GHT)

  4. EFFECT OF POLONIUM /cap alpha/ RADIATION ON GELATINE (in French)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ader, M.

    1962-08-01

    When a nuclear plate, which has been exposed to radiation, developed, and dried, is exposed to a Po source, no effect can be detected by either the eye or the microscope. However if the plate is placed in distilled water, the emulsion thickness of the irradiated region is reduced by approximately 20 mu . A ridge'' separates this region from the nonirradiated region. The ridge contains piles of silver grains, very deformed traces of the old radiation, and some gelatin fragments. It appears that the alpha particles penetrating the gelatine transforms this gelatin, reversible protein, into a substance soluble'' inmore » distilled water or entrained by the distilled water. (J.S.R.)« less

  5. A High Space Density of Luminous Lyman Alpha Emitters at z ∼ 6.5

    NASA Astrophysics Data System (ADS)

    Bagley, Micaela B.; Scarlata, Claudia; Henry, Alaina; Rafelski, Marc; Malkan, Matthew; Teplitz, Harry; Dai, Y. Sophia; Baronchelli, Ivano; Colbert, James; Rutkowski, Michael; Mehta, Vihang; Dressler, Alan; McCarthy, Patrick; Bunker, Andrew; Atek, Hakim; Garel, Thibault; Martin, Crystal L.; Hathi, Nimish; Siana, Brian

    2017-03-01

    We present the results of a systematic search for Lyα emitters (LAEs) at 6≲ z≲ 7.6 using the HST WFC3 Infrared Spectroscopic Parallel (WISP) Survey. Our total volume over this redshift range is ∼ 8× {10}5 Mpc3, comparable to many of the narrowband surveys despite their larger area coverage. We find two LAEs at z = 6.38 and 6.44 with line luminosities of {L}Lyα }∼ 4.7× {10}43 erg s‑1, putting them among the brightest LAEs discovered at these redshifts. Taking advantage of the broad spectral coverage of WISP, we are able to rule out almost all lower-redshift contaminants. The WISP LAEs have a high number density of 7.7× {10}-6 Mpc‑3. We argue that the LAEs reside in megaparsec-scale ionized bubbles that allow the Lyα photons to redshift out of resonance before encountering the neutral intergalactic medium. We discuss possible ionizing sources and conclude that the observed LAEs alone are not sufficient to ionize the bubbles.

  6. Effect of metallic iron on the oxidative dissolution of UO2 doped with a radioactive alpha emitter in synthetic Callovian-Oxfordian groundwater

    NASA Astrophysics Data System (ADS)

    Odorowski, Mélina; Jegou, Christophe; De Windt, Laurent; Broudic, Véronique; Jouan, Gauthier; Peuget, Sylvain; Martin, Christelle

    2017-12-01

    In the hypothesis of direct disposal of spent fuel in a geological nuclear waste repository, interactions between the fuel mainly composed of UO2 and its environment must be understood. The dissolution rate of the UO2 matrix, which depends on the redox conditions on the fuel surface, will have a major impact on the release of radionuclides into the environment. The reducing conditions expected for a geological disposal situation would appear to be favorable as regards the solubility and stability of the UO2 matrix, but may be disturbed on the surface of irradiated fuel. In particular, the local redox conditions will result from a competition between the radiolysis effects of water under alpha irradiation (simultaneously producing oxidizing species like H2O2, hydrogen peroxide, and reducing species like H2, hydrogen) and those of redox active species from the environment. In particular, Fe2+, a strongly reducing aqueous species coming from the corrosion of the iron canister or from the host rock, could influence the dissolution of the fuel matrix. The effect of iron on the oxidative dissolution of UO2 was thus investigated under the conditions of the French disposal site, a Callovian-Oxfordian clay formation chosen by the French National Radioactive Waste Management Agency (Andra), here tested under alpha irradiation. For this study, UO2 fuel pellets doped with a radioactive alpha emitter (238/239Pu) were leached in synthetic Callovian-Oxfordian groundwater (representative of the French waste disposal site groundwater) in the presence of a metallic iron foil to simulate the steel canister. The pellets had varying levels of alpha activity, in order to modulate the concentrations of species produced by water radiolysis on the surface and to simulate the activity of aged spent fuel after 50 and 10,000 years of alpha radioactivity decay. The experimental data showed that whatever the sample alpha radioactivity, the presence of iron inhibits the oxidizing dissolution of UO2 and leads to low uranium concentrations (between 4 × 10-10 and 4 × 10-9 M), through a reactional mechanism located in the very first microns of the UO2/water reactional interface. The mechanism involves consumption of oxidizing species, in particular of H2O2 by Fe2+ at the precise place where these species are produced, and is accompanied by the precipitation of an akaganeite-type Fe3+ hydroxide on the surface. The higher the radioactivity of the samples, the greater the precipitation induced. Modeling has been developed, coupling chemistry with transport and based on the main reactional mechanisms identified, which enables accurate reproduction of the mineralogy of the system under study, giving the nature of the phases under observation as well as the location of their precipitation. Obviously without excluding a potential contribution from the hydrogen produced by the anoxic corrosion of the iron foil, this study has shown that iron plays a major role in this oxidizing dissolution inhibition process for the system investigated (localized alpha radiolysis). This inhibitor effect associated with iron is therefore strongly dependent on the location of the redox front, which is found on the surface in the case of alpha irradiation UO2/water reactional interface.

  7. Alpha-particle radiotherapy: For large solid tumors diffusion trumps targeting.

    PubMed

    Zhu, Charles; Sempkowski, Michelle; Holleran, Timothy; Linz, Thomas; Bertalan, Thomas; Josefsson, Anders; Bruchertseifer, Frank; Morgenstern, Alfred; Sofou, Stavroula

    2017-06-01

    Diffusion limitations on the penetration of nanocarriers in solid tumors hamper their therapeutic use when labeled with α-particle emitters. This is mostly due to the α-particles' relatively short range (≤100 μm) resulting in partial tumor irradiation and limited killing. To utilize the high therapeutic potential of α-particles against solid tumors, we designed non-targeted, non-internalizing nanometer-sized tunable carriers (pH-tunable liposomes) that are triggered to release, within the slightly acidic tumor interstitium, highly-diffusive forms of the encapsulated α-particle generator Actinium-225 ( 225 Ac) resulting in more homogeneous distributions of the α-particle emitters, improving uniformity in tumor irradiation and increasing killing efficacies. On large multicellular spheroids (400 μm-in-diameter), used as surrogates of the avascular areas of solid tumors, interstitially-releasing liposomes resulted in best growth control independent of HER2 expression followed in performance by (a) the HER2-targeting radiolabeled antibody or (b) the non-responsive liposomes. In an orthotopic human HER2-negative mouse model, interstitially-releasing 225 Ac-loaded liposomes resulted in the longest overall and median survival. This study demonstrates the therapeutic potential of a general strategy to bypass the diffusion-limited transport of radionuclide carriers in solid tumors enabling interstitial release from non-internalizing nanocarriers of highly-diffusing and deeper tumor-penetrating molecular forms of α-particle emitters, independent of cell-targeting. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Feasibility of observing the α decay chains from isotopes of SHN with Z = 128, Z = 126, Z = 124 and Z = 122

    NASA Astrophysics Data System (ADS)

    Santhosh, K. P.; Priyanka, B.; Nithya, C.

    2016-11-01

    Within the Coulomb and proximity potential model for deformed nuclei (CPPMDN), the alpha decay properties of 34 isotopes of the superheavy nuclei with Z = 128 within the range 306 ≤ A ≤ 339 have been studied, considering both the parent and daughter nuclei to be deformed. The manuscript also deals with the decay properties of the isotopes of Z = 126 (within 288 ≤ A ≤ 339), Z = 124 (within 284 ≤ A ≤ 339) and Z = 122 (within 280 ≤ A ≤ 339). The alpha decay half lives thus evaluated have been compared with the values evaluated using other theoretical models and it was seen that, our theoretical alpha decay half lives match well with these values. Through the present study, we have underlined and have established the fact that, among the 192 isotopes considered in the present study, only those isotopes 321-324,328-335128, 318-320,323-327126, 305-308,315-322124 and 298-307,311-314122 can be synthesised and detected through alpha decay in laboratory. As the alpha decay half lives of these superheavy isotopes lie within the experimental limits, we hope these predictions, on the decay modes of these unknown nuclei, to pave the way for the future experiments. The proton separation energy calculations on 306-339128, 288-336126, 284-339124 and 280-339122 superheavy nuclei have also been done and the study revealed the probable proton emitters among these nuclei.

  9. Plutonium and uranium determination in environmental samples: combined solvent extraction-liquid scintillation method.

    PubMed

    McDowell, W J; Farrar, D T; Billings, M R

    1974-12-01

    A method for the determination of uranium and plutonium by a combined high-resolution liquid scintillation-solvent extraction method is presented. Assuming a sample count equal to background count to be the detection limit, the lower detection limit for these and other alpha-emitting nuclides is 1.0 dpm with a Pyrex sample tube, 0.3 dpm with a quartz sample tube using present detector shielding or 0.02 d.p.m. with pulse-shape discrimination. Alpha-counting efficiency is 100%. With the counting data presented as an alpha-energy spectrum, an energy resolution of 0.2-0.3 MeV peak half-width and an energy identification to +/-0.1 MeV are possible. Thus, within these limits, identification and quantitative determination of a specific alpha-emitter, independent of chemical separation, are possible. The separation procedure allows greater than 98% recovery of uranium and plutonium from solution containing large amounts of iron and other interfering substances. In most cases uranium, even when present in 10(8)-fold molar ratio, may be quantitatively separated from plutonium without loss of the plutonium. Potential applications of this general analytical concept to other alpha-counting problems are noted. Special problems associated with the determination of plutonium in soil and water samples are discussed. Results of tests to determine the pulse-height and energy-resolution characteristics of several scintillators are presented. Construction of the high-resolution liquid scintillation detector is described.

  10. A Radium-223 Microgenerator from Cyclotron-Produced Trace Actinium-227

    PubMed Central

    Abou, Diane S.; Pickett, Juile; Mattson, John E.; Thorek, Daniel L. J.

    2016-01-01

    The alpha particle emitter Radium-223 dichloride (223RaCl2) has recently been approved for treatment of late-stage bone metastatic prostate cancer. There is considerable interest in studying this new agent outside of the clinical setting, however the supply of 223Ra is limited and expensive. We have engineered a 223Ra microgenerator using traces of 227Ac previously generated from cyclotron-produced 225Ac. Radiochemically pure 223RaCl2 was made, characterized, evaluated in vivo, and the source was recovered in high yield for regeneration of the microgenerator. PMID:27835737

  11. A comparative study of p(+)n and n(+)p InP solar cells made by a closed ampoule diffusion

    NASA Technical Reports Server (NTRS)

    Faur, M.; Faur, M.; Flood, D. J.; Weinberg, I.; Brinker, D. J.; Goradia, C.; Fatemi, N.; Goradia, M.; Thesling, W.

    1991-01-01

    The purpose was to demonstrate the possibility of fabricating thermally diffused p(+)n InP solar cells having high open-circuit voltage without sacrificing the short circuit current. The p(+)n junctions were formed by closed-ampoule diffusion of Cd through a 3 to 5 nm thick anodic or chemical phosphorus-rich oxide cap layer grown on n-InP:S Czochralski LEC grown substrates. For solar cells made by thermal diffusion the p(+)n configuration is expected to have a higher efficiency than the n(+)p configuration. It is predicted that the AM0, BOL efficiencies approaching 19 percent should be readily achieved providing that good ohmic front contacts could be realized on the p(+) emitters of thickness lower than 1 micron.

  12. The uteroglobin fold.

    PubMed

    Callebaut, I; Poupon, A; Bally, R; Demaret, J P; Housset, D; Delettré, J; Hossenlopp, P; Mornon, J P

    2000-01-01

    Uteroglobin (UTG) forms a fascinating homodimeric structure that binds small- to medium-sized ligands through an internal hydrophobic cavity, located at the interface between the two monomers. Previous studies have shown that UTG fold is not limited to the UTG/CC10 family, whose sequence/structure relationships are highlighted here, but can be extended to the cap domain of Xanthobacter autotrophicus haloalkane dehalogenase. We show here that UTG fold is adopted by several other cap domains within the alpha/beta hydrolase family, making it a well-suited "geode" structure allowing it to sequester various hydrophobic molecules. Additionally, some data about a new crystal form of oxidized rabbit UTG are presented, completing previous structural studies, as well as results from molecular dynamics, suggesting an alternative way for the ligand to reach the internal cavity.

  13. Time variations of magnetospheric intensities of outer zone protons, alpha particles and ions (Z greater than or equal to 2). Ph.D. Thesis

    NASA Technical Reports Server (NTRS)

    Randall, B. A.

    1973-01-01

    A comprehensive study of the temporal behavior of trapped protons, alpha particles and ions (Z 2) in outer zone of the earth's magnetosphere has been made. These observations were made by the Injun V satellite during the first 21 months of operation, August 1968 to May 1970. Rapid increases in the observed number of particles followed by slower exponential decay characterize the data. Comparisons are made with the temporal behavior of interplanetary particles of the same energy observed by Explorer 35. Increases in the trapped fluxes generally correspond to enhanced interplanetary activity. The energy spectra of protons and alpha particles at L = 3 have similar shapes when compared on an energy per charge basis while the respective polar cap spectra have similar shape on an energy per nucleon basis. Apparent inward trans-L motion of energetic protons is observed. These particles are diffused inward by a process involving fluctuating electric fields. The loss of trapped low altitude protons, alpha particles and ions (Z 2) is controlled by coulombic energy loss in the atmosphere.

  14. The BetaCage, an ultra-sensitive screener for surface contamination

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bunker, R.; Bowles, M. A.; Schnee, R. W.

    Material screening for identifying low-energy electron emitters and alpha-decaying isotopes is now a prerequisite for rare-event searches (e.g., dark-matter direct detection and neutrinoless double-beta decay) for which surface radiocon-tamination has become an increasingly important background. The BetaCage, a gaseous neon time-projection chamber, is a proposed ultra-sensitive (and nondestructive) screener for alpha-and beta-emitting surface contaminants to which existing screening facilities are insufficiently sensitive. Sensitivity goals are 0.1 betas keV{sup −1} m{sup −2} day{sup −1} and 0.1 alphas m{sup −2} day{sup −1}, with the former limited by Compton scattering of photons in the screening samples and (thanks to tracking) the latter expectedmore » to be signal-limited; radioassays and simulations indicate backgrounds from detector materials and radon daughters should be subdominant. We report on details of the background simulations and detector design that provide the discrimination, shielding, and radiopurity necessary to reach our sensitivity goals for a chamber with a 95 × 95 cm{sup 2} sample area positioned below a 40 cm drift region and monitored by crisscrossed anode and cathode planes consisting of 151 wires each.« less

  15. Initial Results of a Far-Ultraviolet Spectroscopic Survey of Nearby Star-forming Galaxies with the Cosmic Origins Spectrograph

    NASA Astrophysics Data System (ADS)

    Redwine, Keith; McCandliss, Stephan R.; Wofford, Aida; Leitherer, Claus; Heckman, Timothy M.; France, Kevin; Fleming, Brian

    2017-01-01

    We present initial results for the HST Cycle 22 proposal 13761. We proposed to observe 75 target star-forming galaxies at a redshift 0.02 < z < 0.24 in the G140L mode of COS, spanning a bandpass of 1100 < λ < 2400 angstroms, and have thus far observed 34 of them. The main thrust of this project is to provide a previously unavailable survey of star-forming galaxies in this redshift range, allowing investigation into the factors that determine the Lyman-alpha emission at these low redshifts. We have begun a statistical analysis of the relationship between Lyman-alpha emission and the morphologies of the galaxies, such as absorption line strengths of other species, including various ionization states of oxygen, silicon, and other species to probe intrinsic properties of the emitting galaxy, such as metallicity, the gas-to-dust ratio, and local velocity fields. We have acquired a very rich dataset, with enough samples to try to answer a variety of open questions regarding the far-ultraviolet spectra of bright Lyman-alpha emitters. This work is supported by a NASA Grant HST-GO-13761 to the Johns Hopkins University.

  16. Nanostructured Solar Irradiation Control Materials for Solar Energy Conversion

    NASA Technical Reports Server (NTRS)

    Kang, Jinho; Marshall, I. A.; Torrico, M. N.; Taylor, C. R.; Ely, Jeffry; Henderson, Angel Z.; Kim, J.-W.; Sauti, G.; Gibbons, L. J.; Park, C.; hide

    2012-01-01

    Tailoring the solar absorptivity (alpha(sub s)) and thermal emissivity (epsilon(sub T)) of materials constitutes an innovative approach to solar energy control and energy conversion. Numerous ceramic and metallic materials are currently available for solar absorbance/thermal emittance control. However, conventional metal oxides and dielectric/metal/dielectric multi-coatings have limited utility due to residual shear stresses resulting from the different coefficient of thermal expansion of the layered materials. This research presents an alternate approach based on nanoparticle-filled polymers to afford mechanically durable solar-absorptive and thermally-emissive polymer nanocomposites. The alpha(sub s) and epsilon(sub T) were measured with various nano inclusions, such as carbon nanophase particles (CNPs), at different concentrations. Research has shown that adding only 5 wt% CNPs increased the alpha(sub s) and epsilon(sub T) by a factor of about 47 and 2, respectively, compared to the pristine polymer. The effect of solar irradiation control of the nanocomposite on solar energy conversion was studied. The solar irradiation control coatings increased the power generation of solar thermoelectric cells by more than 380% compared to that of a control power cell without solar irradiation control coatings.

  17. Age and seasonal differences in the synthesis and metabolism of testosterone by testicular tissue and pineal HIOMT activity of Uinta ground squirrels (Spermophilus armatus)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ellis, L.C.; Balph, D.F.

    Male Uinta ground squirrels (Spermophilus armatus) were sacrificed from a free-living population during the breeding season, which immediately followed emergence from hibernation; after the reproductive season; and just prior to aestivation/hibernation. HIOMT activity of the pineal gland was assayed and related to the ability of the gonads to synthesize and metabolize testosterone. Older squirrels had higher HIOMT activity than did the younger animals. The activity of this enzyme was lowest in squirrels during the breeding season. HIOMT activity increased after the breeding season to its highest level just before the squirrels enter aestivation/hibernation. At this time, testicular weight increased concomitantmore » with an apparent increase in HIOMT activity. Testicular size and weight were largest at the time of emergence of the animals from hibernation. Androgen synthesis was also greatest during the breeding season. As would be expected, both decreased rapidly thereafter. The testes formed little 17..cap alpha..,20..cap alpha..-dihydroxyprogesterone during or after the breeding season, contrary to what has been reported for rats and house sparrows. The older squirrels demonstrated a greater capacity for testosterone metabolism during the breeding season than did the younger animals.« less

  18. Fluorescence alteration of MPA capped CdSe quantum dots by spontaneous biomarker protein adsorption.

    PubMed

    Rowley, Amber; Parks, Tegan; Parks, Kaden; Medley, Kyle; Cordner, Alex; Yu, Ming

    2018-05-23

    Quantum dots (QDs) have significant potentials in biomedical applications of bioimaging and biosensing. Spontaneous adsorption of proteins on QDs surface is a common phenomenon, which occurred to serum proteins in biological samples, and has been observed to enhance QDs fluorescence. In this study, fluorescence alteration of 3-mercaptopropionic acid (MPA) capped CdSe quantum dots by four individual biomarker proteins was investigated. By monitoring the fluorescence emission of QDs, the biomarker protein adsorbed spontaneously on QDs surface was recognized and quantified. When alpha fetoprotein (AFP) or heat shock protein 90 alpha (HSP90α) were present, the QDs became brighter. The presence of cytochrome C (CytoC) or lysozyme (Lyz) made the QDs dimmer first, and then brighter. Within 5 min response time all four biomarker proteins were detected individually with the estimated detection limit in the range of 1-10 ng/mL and good linear dynamic ranges. The results suggested that the fluorescence of QDs was responsive to not only serum proteins but also biomarker proteins. The fluorescence response was able to correlate quantitatively with the amount of biomarker proteins in relatively low concentrations. These results provide more information to understand QDs and support their applications in biomedical fields. Copyright © 2018. Published by Elsevier Inc.

  19. Role of calcium in the constriction of isolated cerebral arteries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wendling, W.W.

    1987-01-01

    Calcium entry blockers (CEB) have been used in the experimental treatment or prevention of many cerebrovascular disorders including stroke, post-ischemic hypoperfusion after cardiac arrest, cerebral vasospasm after subarachnoid hemorrhage, and migraine headache. However, the mechanism of action of these drugs on the cerebral circulation is poorly understood. This study examined the effects of calcium antagonists, Ca/sup 2 +/-deficient solutions, and vasocostrictors on cerebrovascular tone and /sup 45/Ca fluxes, to determine the role of calcium in cerebral arterial constriction. A Scatchard plot of /sup 45/Ca binding to BMCA showed that Ca/sup 2 +/ was bound at either low or high affinitymore » binding sties. The four vasoconstrictors (potassium, serotonin, PGF/sub 2 ..cap alpha../, or SQ-26,655) each increased low affinity /sup 45/Ca uptake into BMCA. The results demonstrate that: (1) Potassium and serotonin constrict BMCA mainly by promoting Ca/sup 2 +/ influx through CEB-sensitive channels; (2) PGF/sub 2 ..cap alpha../ and SQ-26,655 constrict BMCA in part by promoting Ca/sup 2 +/ influx through CEB-sensitive channels, and in part by releasing Ca/sup 2 +/ from depletable internal stores; (3) The major action of CEB on BMCA is to block vasoconstrictor-induced Ca/sup 2 +/ uptake through both potential-operated (K/sup +/-stimulated) and receptor-operated channels.« less

  20. Neutral amino acid transport across brain microvessel endothelial cell monolayers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Audus, K.L.; Borchardt, R.T.

    1986-03-01

    Brain microvessel endothelial cells (BMEC) which form the blood-brain barrier (BBB) possess an amino acid carrier specific for large neutral amino acids (LNAA). The carrier is important for facilitating the delivery of nutrient LNAA's and centrally acting drugs that are LNAA's, to the brain. Bovine BMEC's were isolated and grown up to complete monolayers on regenerated cellulose-membranes in primary culture. To study the transendothelial transport of leucine, the monolayers were placed in a side-by-side diffusion cell, and transport across the monolayers followed with (/sup 3/H)-leucine. The transendothelial transport of leucine in this in vitro model was determined to be bidirectional,more » and time-, temperature-, and concentration-dependent. The transport of leucine was saturable and the apparent K/sub m/ and V/sub max/, 0.18 mM and 6.3 nmol/mg/min, respectively. Other LNAA's, including the centrally acting drugs, ..cap alpha..-methyldopa, L-DOPA, ..cap alpha..-methyl-tyrosine, and baclofen, inhibited leucine transport. The leucine carrier was also found to be stereospecific and not sensitive to inhibitors of active transport. These results are consistent with previous in vitro and in vivo studies. Primary cultures of BMEC's appear to be a potentially important tool for investigating at the cellular level, the transport mechanisms of the BBB.« less

  1. Imidazoline ring cleavage in 1,3,6,10-tetraazatetracyclo-(7. 3. 1. 0/sup 2,7/. 0/sup 6,13/)trideca-4,11-dienes, leading to the formation of diquinoxalino(1,2-. cap alpha. :2',3'-d)pyrrole derivatives

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Charushin, V.N.; Petrova, G.M.; Aleksandrov, G.G.

    1987-10-01

    Dibenzo(d,k)-1,3,6,10-tetraazatetracyclo(7.3.1.0/sup 2,7/.0/sup 6,13/) trideca-4,11-dienes undergo addition reactions at the C/sub (2)/ carbon atom with alcohols and thiols, accompanied by cleavage of the C-N bond of the imidazoline ring, to generate diquinoxalino(1,2-..cap alpha..:2',3'-d)pyrrole derivatives. /sup 1/H NMR spectra were recorded on Perkin-Elmer R 12B (60 MHz) and Bruker WH-90 spectrometer for CDCl/sub 3/ solutions at 40/sup 0/C and with TMS as internal standard. /sup 13/C NMR spectra were obtained on a Bruker WH-90 (22.62 MHz) spectrometer. /sup 13/C chemical shifts were measured relative to solvent signals (deltaCDCl/sub 3/ 77.0 ppm). /sup 13/C NMR spectra of compounds IIa and g were takenmore » using full spin-spin carbon-proton decoupling. In order to measure SSCC the spectrum was recorded both with proton coupling and also with selective decoupling of individual protons and their attached /sup 13/C carbon nuclei.« less

  2. Characterization of HeLa 5'-nucleotidase: a stable plasma membrane marker

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brake, E.T.; Will, P.C.; Cook, J.S.

    1977-11-22

    The enzyme 5'-nucleotidase, assayed as 5'-AMPase, has been extensively characterized and established as a stable, quantitative plasma membrane marker in HeLa S3 cells. The 5'-AMPase has a K/sub m/ of 7.0 ..mu..m. There are activity optima at pH7 and 10; the latter is Mg/sup 2 +/-dependent. The membrane preparations have a small amount of acid phosphatase activity that is distinct from 5'-AMPase activity but no alkaline phosphatase. ADP, ATP and ..cap alpha.., ..beta..-methylene adenosine-5'-diphosphate are strongly inhibitory. Mg/sup 2 +/, Ca/sup 2 +/, or Co/sup 2 +/ do not affect the pH 7.0 activity; Mn/sup 2 +/ activates slightly, whereasmore » Zn/sup 2 +/, Cu/sup 2 +/, and Ni/sup 2 +/ are inhibitory. EDTA slowly inactivates, but removal of the EDTA without the addition of divalent cations restores activity. The inactivation is also substantially reversed by Co/sup 2 +/ or Mn/sup 2 +/. ConA strongly inhibits, and ..cap alpha..-methyl-D-mannoside or glucose relieves the inhibition, indicating that the 5'-AMPase is a glycoprotein. Histidine is also inhibitory. Ouabain, phloretin, cytochalasin B, cysteine, phenylalanine, N-ethylmaleimide, and iodoacetic acid are without effect.« less

  3. Anisotropy of the Fermi surface, Fermi velocity, many-body enhancement, and superconducting energy gap in Nb

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crabtree, G.W.; Dye, D.H.; Karim, D.P.

    1987-02-01

    The detailed angular dependence of the Fermi radius k/sub F/, the Fermi velocity v/sub F/(k), the many-body enhancement factor lambda(k), and the superconducting energy gap ..delta..(k), for electrons on the Fermi surface of Nb are derived with use of the de Haas--van Alphen (dHvA) data of Karim, Ketterson, and Crabtree (J. Low Temp. Phys. 30, 389 (1978)), a Korringa-Kohn-Rostoker parametrization scheme, and an empirically adjusted band-structure calculation of Koelling. The parametrization is a nonrelativistic five-parameter fit allowing for cubic rather than spherical symmetry inside the muffin-tin spheres. The parametrized Fermi surface gives a detailed interpretation of the previously unexplained kappa,more » ..cap alpha..', and ..cap alpha..'' orbits in the dHvA data. Comparison of the parametrized Fermi velocities with those of the empirically adjusted band calculation allow the anisotropic many-body enhancement factor lambda(k) to be determined. Theoretical calculations of the electron-phonon interaction based on the tight-binding model agree with our derived values of lambda(k) much better than those based on the rigid-muffin-tin approximation. The anisotropy in the superconducting energy gap ..delta..(k) is estimated from our results for lambda(k), assuming weak anisotropy.« less

  4. Polyamidoamine dendrimers-capped carbon dots/Au nanocrystal nanocomposites and its application for electrochemical immunosensor.

    PubMed

    Gao, Qi; Han, Jingman; Ma, Zhanfang

    2013-11-15

    In this work, polyamidoamine dendrimers capped-carbon dots (PAMAM-CDs) were fabricated by one-step microwave assisted pyrolysis of citric acid (CA) and PAMAM, where the formation of CDs and the surface passivation were accomplished simultaneously. The obtained graphitic PAMAM-CDs, with abundant amine groups, were employed as reducing and capping agents for the formation of PAMAM-CDs/Au nanocrystal nanocomposites. The resulting nanocomposites exhibited excellent conductivity, stability and biocompatibility on the surface of electrode and were designed as an immobilized matrix for sensitive immunosensing of alpha-fetoprotein (AFP). The proposed immunosensor showed a wide linear detection range from 100 fg mL(-1) to 100 ng mL(-1). The detection limit for AFP was 0.025 pg mL(-1). Importantly, the immunosensor was evaluated for the analysis of clinical serum samples, obtaining a good correlation with enzyme-linked immunosorbent assay (ELISA). The results indicated that the immunosensor provided a possible application for the detection of AFP in clinical diagnosis. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Therapeutic Efficacy of Alpha-RIT Using a (213)Bi-Anti-hCD138 Antibody in a Mouse Model of Ovarian Peritoneal Carcinomatosis.

    PubMed

    Derrien, Aurélie; Gouard, Sébastien; Maurel, Catherine; Gaugler, Marie-Hélène; Bruchertseifer, Frank; Morgenstern, Alfred; Faivre-Chauvet, Alain; Classe, Jean-Marc; Chérel, Michel

    2015-01-01

    Ovarian peritoneal carcinomatosis is a pathology for which effective cures are currently lacking. New research protocols seek to eradicate residual micrometastases following cytoreductive surgery by using hyperthermic intraperitoneal chemotherapy (HIPEC) or radioimmunotherapy (RIT). This study aims to first develop alpha-RIT using an anti-CD138 mAb radiolabeled with an alpha-emitter, bismuth-213 ((213)Bi-B-B4) and HIPEC in a nude mouse model and second to compare and combine these techniques. A murine model of postoperative ovarian peritoneal carcinomatosis was established. A pilot group of six mice received an intraperitoneal injection of luciferase-tagged SHIN-3 cells and bioluminescence was measured every day. Cytoreductive surgery was performed at day 14 (n = 4) and 29 (n = 2). Because the residual bioluminescence signal measured after surgery was equivalent to that obtained 3 days after the graft, HIPEC or alpha-RIT treatments were applied 3 days after the graft. Ten mice were treated by HIPEC with cisplatine (37.5 mg/mL), 11 with 7.4 MBq of (213)Bi-B-B4, seven with 11.1 MBq of (213)Bi-B-B4, and 10 mice were treated with the combined therapy (HIPEC + 7.4 MBq of (213)Bi-B-B4). Eleven mice received no treatment. Bioluminescence imaging and survival were assessed. Alpha-RIT 7.4 MBq and 11.1 MBq significantly improved survival (p = 0.0303 and p = 0.0070, respectively), whereas HIPEC and HIPEC + alpha-RIT treatments did not significantly ameliorate survival as compared to the control group. Survival was significantly increased by alpha-RIT treatment in mice with peritoneal carcinomatosis of ovarian origin; however, HIPEC alone or in combination with alpha-RIT had no significant effect.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    none

    This report is the first quarterly report under Contract AT(30-1)-2528 for the decontamination and recovery of precious metals from contaminated scrap. This program encompasses the recovery of gold, platinum, iridium, rhodium and palladium from scrap and contaminated laboratory ware, equipment, etc. which may be contaminated by alpha emitters (i.e., uranium, plutonium and possibly polonium or combinations of these), beta-gamma emitters such as fission products or all three sources of radiation. In addition the scrap can be chemically contaminated by base metals, graphite or other contaminants. Osmium, ruthenium or silver are not to be recovered. Since the scrap can exist inmore » such a great variety of forms such as platinum-rhodium laboratory crucibles, graphite crucibles containing platinum-base metal alloys derived from vacuum fusion baths, insulated thermocouple wires, reactor liners, porous platinum filters, alloys such as Baker alloy 413 (60 Au, 25 Pd, 15 Pt) it may be necessary to devise specific methods for a given type of scrap. Nevertheless the basic chemistry is the same and information and methods applicable to single systems will apply directly to the more complicated ones. Accordingly the relatively simple systems would be investigated first and the more complicated ones later in the program. An essential and major contribution to the success of the program is to devise or adapt accurate and precise analytical chemical techniques for scrap identification, process control, purity of the final products and accountability control. Accordingly, the emphasis on chemical analysis will be proportionally greater during the early stages of the program. The residual activity level to be attained is presently stated at twice the standard deviation obtained in low background counters (alpha {approx}0.1 c/m, beta {approx} 5 c/m) of virgin platinum.« less

  7. Thermal Optical Properties of Lunar Dust Simulants and Their Constituents

    NASA Technical Reports Server (NTRS)

    Gaier, James R.; Ellis, Shaneise; Hanks, Nichole

    2011-01-01

    The total reflectance spectra of lunar simulant dusts (< 20 mm particles) were measured in order to determine their integrated solar absorptance (alpha) and their thermal emittance (epsilon) for the purpose of analyzing the effect of dust on the performance of thermal control surfaces. All of the simulants except one had a wavelength-dependent reflectivity (p (lambda)) near 0.10 over the wavelength range of 8 to 25 microns and so are highly emitting at room temperature and lower. The 300 K emittance (epsilon) of all the lunar simulants except one ranged from 0.78 to 0.92. The exception was Minnesota Lunar Simulant 1 (MLS-1), which has little or no glassy component. In all cases the epsilon was lower for the < 20 micron particles than for larger particles reported earlier. There was considerably more variation in the lunar simulant reflectance in the solar spectral range (250 to 2500 nm) than in the thermal infrared. As expected, the lunar highlands simulants were more reflective in this wavelength range than the lunar mare simulants. The integrated solar absorptance (alpha) of the simulants ranged from 0.39 to 0.75. This is lower than values reported earlier for larger particles of the same simulants (0.41 to 0.82), and for representative mare and highlands lunar soils (0.74 to 0.91). Since the of some mare simulants more closely matched that of highlands lunar soils, it is recommended that and values be the criteria for choosing a simulant for assessing the effects of dust on thermal control surfaces, rather than whether a simulant has been formulated as a highlands or a mare simulant.

  8. Validation of the French version of the Child Post-Traumatic Stress Reaction Index: psychometric properties in French speaking school-aged children.

    PubMed

    Olliac, Bertrand; Birmes, Philippe; Bui, Eric; Allenou, Charlotte; Brunet, Alain; Claudet, Isabelle; Sales de Gauzy, Jérôme; Grandjean, Hélène; Raynaud, Jean-Philippe

    2014-01-01

    Although the reliable and valid Child Post-Traumatic Stress Reaction Index (CPTS-RI) is a widely used measure of posttraumatic stress disorder (PTSD) symptoms in children, it has not been validated in French-speaking populations. The present study aims to assess the psychometric properties of the CPTS-RI in three samples of French-speaking school-children. Data was obtained from three samples. Sample 1 was composed of 106 children (mean (SD) age = 11.7(0.7), 50% females) victims of an industrial disaster. Sample 2 was composed of 50 children (mean (SD) age = 10.8(2.6), 44% females) who had received an orthopaedic surgical procedure after an accident. Sample 3 was composed of 106 children (mean (SD) age = 11.7(2.2), 44% females) admitted to an emergency department after a road traffic accident. We tested internal consistency using Cronbach's alpha. We examined test-retest reliability using intraclass correlation coefficient. In order to assess the convergent validity of the French version of the CPTS-RI and the Clinician Administered PTS Scale-Child and Adolescent (CAPS-CA), spearman-correlation coefficient was computed. To verify the validity of the cut-off scores, a ROC curve was constructed which evaluated the sensitivity and specificity of each score compared to the diagnosis with the CAPS-CA. We also used principal components analysis with varimax rotation to study the structure of the French version of the CPTS-RI. Cronbach's alpha coefficient was 0.87 for the French version of the CPTS-RI. Two-week test-retest intraclass correlation coefficient (n = 30) was 0.67. The French version of the CPTS-RI was well correlated with the CAPS-CA (r = 0.76, p < 0.001). Taking the CAPS-CA as the diagnostic reference, with a diagnostic cut-off of >24 for the CPTS-RI, the sensitivity and specificities were 100% and 62.6%, respectively. The French version of the CPTS-RI demonstrated a three-factor structure. The CPTS-RI is reliable and valid in French-speaking children.

  9. Introduction of potential helix-capping residues into an engineered helical protein.

    PubMed

    Parker, M H; Hefford, M A

    1998-08-01

    MB-1 is an engineered protein that was designed to incorporate high percentages of four amino acid residues and to fold into a four-alpha-helix bundle motif. Mutations were made in the putative loop I and III regions of this protein with the aim of increasing the stability of the helix ends. Four variants, MB-3, MB-5, MB-11 and MB-13, have replacements intended to promote formation of an 'N-capping box'. The loop I and III sequences of MB-3 (both GDLST) and MB-11 (GGDST) were designed to cause alphaL C-terminal 'capping' motifs to form in helices I and III. MB-5 has a sequence, GPDST, that places proline in a favourable position for forming beta-turns, whereas MB-13 (GLDST) has the potential to form Schellman C-capping motifs. Size-exclusion chromatography suggested that MB-1, MB-3, MB-5, MB-11 and MB-13 all form dimers, or possibly trimers. Free energies for the unfolding of each of these variants were determined by urea denaturation, with the loss of secondary structure followed by CD spectroscopy. Assuming an equilibrium between folded dimer and unfolded monomer, MB-13 had the highest apparent stability (40.5 kJ/mol, with +/-2.5 kJ/mol 95% confidence limits), followed by MB-11 (39.3+/-5.9 kJ/mol), MB-3 (36.4+/-1.7 kJ/mol), MB-5 (34.7+/-2.1 kJ/mol) and MB-1 (29.3+/-1.3 kJ/mol); the same relative stabilities of the variants were found when a folded trimer to unfolded monomer model was used to calculate stabilities. All of the variants were relatively unstable for dimeric proteins, but were significantly more stable than MB-1. These findings suggest that it might be possible to increase the stability of a protein for which the three-dimensional structure is unknown by placing amino acid residues in positions that have the potential to form helix- and turn-stabilizing motifs.

  10. All-night EEG power spectral analysis of the cyclic alternating pattern components in young adult subjects.

    PubMed

    Ferri, Raffaele; Bruni, Oliviero; Miano, Silvia; Plazzi, Giuseppe; Terzano, Mario G

    2005-10-01

    To analyze in detail the frequency content of the different EEG components of the Cyclic Alternating Pattern (CAP), taking into account the ongoing EEG background and the nonCAP (NCAP) periods in the whole night polysomnographic recordings of normal young adults. Sixteen normal healthy subjects were included in this study. Each subject underwent one polysomnographic night recording; sleep stages were scored following standard criteria. Subsequently, each CAP A phase was detected in all recordings, during NREM sleep, and classified into 3 subtypes (A1, A2, and A3). The same channel used for the detection of CAP A phases (C3/A2 or C4/A1) was subdivided into 2-s mini-epochs. For each mini-epoch, the corresponding CAP condition was determined and power spectra calculated in the frequency range 0.5-25 Hz. Average spectra were obtained for each CAP condition, separately in sleep stage 2 and SWS, for each subject. Finally, the first 6h of sleep were subdivided into 4 periods of 90 min each and the same spectral analysis was performed for each period. During sleep stage 2, CAP A subtypes differed from NCAP periods for all frequency bins between 0.5 and 25 Hz; this difference was most evident for the lowest frequencies. The B phase following A1 subtypes had a power spectrum significantly higher than that of NCAP, for frequencies between 1 and 11 Hz. The B phase after A2 only differed from NCAP for a small but significant reduction in the sigma band power; this was evident also after A3 subtypes. During SWS, we found similar results. The comparison between the different CAP subtypes also disclosed significant differences related to the stage in which they occurred. Finally, a significant effect of the different sleep periods was found on the different CAP subtypes during sleep stage 2 and on NCAP in both sleep stage 2 and SWS. CAP subtypes are characterized by clearly different spectra and also the same subtype shows a different power spectrum, during sleep stage 2 or SWS. This finding underlines a probable different functional meaning of the same CAP subtype during different sleep stages. We also found 3 clear peaks of difference between CAP subtypes and NCAP in the delta, alpha, and beta frequency ranges which might indicate the presence of 3 frequency components characterizing CAP subtypes, in different proportion in each of them. The B component of CAP differs from NCAP because of a decrease in power in the sigma frequency range. This study shows that A components of CAP might correspond to periods in which the very-slow delta activity of sleep groups a range of different EEG activities, including the sigma and beta bands, while the B phase of CAP might correspond to a period in which this activity is quiescent or inhibited.

  11. Mechanism of the lysosomal membrane enzyme acetyl coenzyme A: alpha-glucosaminide N-acetyltransferase

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bame, K.J.

    1986-01-01

    Acetyl-CoA:..cap alpha..-glucosaminide N-acetyltransferase is a lysosomal membrane enzyme, deficient in the genetic disease Sanfilippo C syndrome. The enzyme catalyzes the transfer of an acetyl group from cytoplasmic acetyl-CoA to terminal ..cap alpha..-glucosamine residues of heparan sulfate within the organelle. The reaction mechanism was examined using high purified lysosomal membranes from rat liver and human fibroblasts. The N-acetyltransferase reaction is optimal above pH 5.5 and a 2-3 fold stimulation of activity is observed in the presence of 0.1% taurodeoxycholate. Double reciprocal analysis and product inhibition studies indicate that the enzyme works by a Di-Iso Ping Pong Bi Bi mechanism. The bindingmore » of acetyl-CoA to the enzyme is measured by exchange label from (/sup 3/H)CoA to acetyl-CoA, and is optimal at pH's above 7.0. The acetyl-enzyme intermediate is formed by incubating membranes with (/sup 3/H)acetyl-CoA. The acetyl group can be transferred to glucosamine, forming (/sup 3/H)N-acetylglucosamine; the transfer is optimal between pH 4 and 5. Lysosomal membranes from Sanfilippo C fibroblasts confirm that these half reactions carried out by the N-acetyltransferase. The enzyme is inactivated by N-bromosuccinimide and diethylpyrocarbonate, indicating that a histidine is involved in the reaction. These results suggest that the histidine residue is at the active site of the enzyme. The properties of the N-acetyltransferase in the membrane, the characterization of the enzyme kinetics, the chemistry of a histidine mediated acetylation and the pH difference across the lysosomal membrane all support a transmembrane acetylation mechanism.« less

  12. Rapid determination of alpha emitters using Actinide resin.

    PubMed

    Navarro, N; Rodriguez, L; Alvarez, A; Sancho, C

    2004-01-01

    The European Commission has recently published the recommended radiological protection criteria for the clearance of building and building rubble from the dismantling of nuclear installations. Radionuclide specific clearance levels for actinides are very low (between 0.1 and 1 Bq g(-1)). The prevalence of natural radionuclides in rubble materials makes the verification of these levels by direct alpha counting impossible. The capability of Actinide resin (Eichrom Industries, Inc.) for extracting plutonium and americium from rubble samples has been tested in this work. Besides a strong affinity for actinides in the tri, tetra and hexavalent oxidation states, this extraction chromatographic resin presents an easy recovery of absorbed radionuclides. The retention capability was evaluated on rubble samples spiked with certified radionuclide standards (239Pu and 241Am). Samples were leached with nitric acid, passed through a chromatographic column containing the resin and the elution fraction was measured by LSC. Actinide retention varies from 60% to 80%. Based on these results, a rapid method for the verification of clearance levels for actinides in rubble samples is proposed.

  13. Removal of Long-Lived Radon Daughters by Electropolishing Thin Layers of Stainless Steel

    NASA Astrophysics Data System (ADS)

    White, James; Schnee, Richard; Bunker, Raymond; Bowles, Michael; Cushman, Priscilla; Epland, Matthew; Pepin, Mark; Guiseppe, Vince

    2012-10-01

    Long-lived alpha and beta emitters in the Radon decay chain on detector surfaces may be limiting background in many experiments attempting to detect dark matter or neutrinoless double beta decay. To screen detector surfaces for this radioactive contamination, a low-radiation, multi-wire proportional chamber (the BetaCage) is under construction. Removal of Pb-210 implanted on its 25-micron stainless steel wires without causing significant variation in the diameter of the wires is critical to the BetaCage's ultimate sensitivity. An apparatus to perform electropolishing trials to remove roughly a micron of material has been assembled. These trials have shown promising results. Stainless steel square samples implanted with Pb-210 have shown counts with a reduction factor greater than 10 after electropolishing according to gamma assay. Furthermore, alpha counting has produced similar results, with a reduction factor greater than 100. Lastly, the diameters of wires after electropolishing have remained sufficiently uniform, with reduction in thickness consistent with expectations.

  14. Large area, low cost space solar cells with optional wraparound contacts

    NASA Technical Reports Server (NTRS)

    Michaels, D.; Mendoza, N.; Williams, R.

    1981-01-01

    Design parameters for two large area, low cost solar cells are presented, and electron irradiation testing, thermal alpha testing, and cell processing are discussed. The devices are a 2 ohm-cm base resistivity silicon cell with an evaporated aluminum reflector produced in a dielectric wraparound cell, and a 10 ohm-cm silicon cell with the BSF/BSR combination and a conventional contact system. Both cells are 5.9 x 5.9 cm and require 200 micron thick silicon material due to mission weight constraints. Normalized values for open circuit voltage, short circuit current, and maximum power calculations derived from electron radiation testing are given. In addition, thermal alpha testing values of absorptivity and emittance are included. A pilot cell processing run produced cells averaging 14.4% efficiencies at AMO 28 C. Manufacturing for such cells will be on a mechanized process line, and the area of coverslide application technology must be considered in order to achieve cost effective production.

  15. Interpreting HST observations with simulations of reionization: the ionizing photon budget and the decline of Lyman-alpha emission in z>6 dropouts

    NASA Astrophysics Data System (ADS)

    D'Aloisio, Anson

    2017-08-01

    In recent years, HST surveys such as CANDELS, HUDF, BoRG/HIPPIES, ERS, and the Frontier Fields, have made possible the first robust measurements of the rest-frame UV luminosity function of z =6-10 galaxies, spanning much of the redshift range over which reionization likely occurred. These measurements provide an estimate of the galactic ionizing photon output, addressing the critical question of whether these galaxies could have reionized the Universe. In addition, follow-up spectroscopy has measured the fraction of these galaxies that show Lyman-alpha emission. Interestingly, a dramatic decrease in this fraction above z 6 has been observed, and this evolution has (controversially) been interpreted as evidence that much of reionization happened over z=6-8 (as intergalactic neutral gas leads to large damping wings that scatter the Lyman-alpha line). The clumpiness of the IGM and how it self shields to ionizing photons impacts whether the observed population of galaxies can reionize the Universe, as well as the interpretation of the evolving Lyman-alpha emitter fraction. We propose to run fully coupled radiative-hydrodynamics simulations that are the first to resolve the evaporation of small structures by passing ionization fronts and, hence, to accurately assess the level of clumpiness and self-shielding from the IGM. Our study will nail down the clumping factor used to assess whether the observed population of galaxies can drive reionization, and it will address whether neutral self-shielding clumps in recently reionized regions can scatter galaxies' Lyman-alpha lines.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hawkins, C.A.

    Tests of QED to order ..cap alpha../sup 4/ performed with the ASP detector at PEP are presented. Measurements have been made of exclusive e/sup +/e/sup -/e/sup +/e/sup -/, e/sup +/e/sup -/..gamma gamma.. and ..gamma gamma gamma gamma.. final states with all particles above 50 milliradians with respect to the e/sup +/e/sup -/ beam line. These measurements represent a significant increase in statistics over previous measurements. All measurements agree well with theoretical predictions. 5 refs., 1 tab.

  17. Binding Linkage in a Telomere DNA–Protein Complex at the Ends of Oxytricha nova Chromosomes

    PubMed Central

    Buczek, Pawel; Orr, Rochelle S.; Pyper, Sean R.; Shum, Mili; Ota, Emily Kimmel Irene; Gerum, Shawn E.; Horvath, Martin P.

    2005-01-01

    Alpha and beta protein subunits of the telomere end binding protein from Oxytricha nova (OnTEBP) combine with telomere single strand DNA to form a protective cap at the ends of chromosomes. We tested how protein–protein interactions seen in the co-crystal structure relate to DNA binding through use of fusion proteins engineered as different combinations of domains and subunits derived from OnTEBP. Joining alpha and beta resulted in a protein that bound single strand telomere DNA with high affinity (KD-DNA=1.4 nM). Another fusion protein, constructed without the C-terminal protein–protein interaction domain of alpha, bound DNA with 200-fold diminished affinity (KD-DNA=290 nM) even though the DNA-binding domains of alpha and beta were joined through a peptide linker. Adding back the alpha C-terminal domain as a separate protein restored high-affinity DNA binding. The binding behaviors of these fusion proteins and the native protein subunits are consistent with cooperative linkage between protein-association and DNA-binding equilibria. Linking DNA–protein stability to protein–protein contacts at a remote site may provide a trigger point for DNA–protein disassembly during telomere replication when the single strand telomere DNA must exchange between a very stable OnTEBP complex and telomerase. PMID:15967465

  18. Enhanced adhesion of films to semiconductors or metals by high energy bombardment

    NASA Technical Reports Server (NTRS)

    Tombrello, Thomas A. (Inventor); Qiu, Yuanxun (Inventor); Mendenhall, Marcus H. (Inventor)

    1985-01-01

    Films (12) of a metal such as gold or other non-insulator materials are firmly bonded to other non-insulators such as semiconductor substrates (10), suitably silicon or gallium arsenide by irradiating the interface with high energy ions. The process results in improved adhesion without excessive doping and provides a low resistance contact to the semiconductor. Thick layers can be bonded by depositing or doping the interfacial surfaces with fissionable elements or alpha emitters. The process can be utilized to apply very small, low resistance electrodes (78) to light-emitting solid state laser diodes (60) to form a laser device 70.

  19. Laser-produced lithium plasma as a narrow-band extended ultraviolet radiation source for photoelectron spectroscopy.

    PubMed

    Schriever, G; Mager, S; Naweed, A; Engel, A; Bergmann, K; Lebert, R

    1998-03-01

    Extended ultraviolet (EUV) emission characteristics of a laser-produced lithium plasma are determined with regard to the requirements of x-ray photoelectron spectroscopy. The main features of interest are spectral distribution, photon flux, bandwidth, source size, and emission duration. Laser-produced lithium plasmas are characterized as emitters of intense narrow-band EUV radiation. It can be estimated that the lithium Lyman-alpha line emission in combination with an ellipsoidal silicon/molybdenum multilayer mirror is a suitable EUV source for an x-ray photoelectron spectroscopy microscope with a 50-meV energy resolution and a 10-mum lateral resolution.

  20. Generation of human induced pluripotent stem cells using non-synthetic mRNA.

    PubMed

    Rohani, L; Fabian, C; Holland, H; Naaldijk, Y; Dressel, R; Löffler-Wirth, H; Binder, H; Arnold, A; Stolzing, A

    2016-05-01

    Here we describe some of the crucial steps to generate induced pluripotent stem cells (iPSCs) using mRNA transfection. Our approach uses a V. virus-derived capping enzyme instead of a cap-analog, ensuring 100% proper cap orientation for in vitro transcribed mRNA. V. virus' 2'-O-Methyltransferase enzyme creates a cap1 structure found in higher eukaryotes and has higher translation efficiency compared to other methods. Use of the polymeric transfection reagent polyethylenimine proved superior to other transfection methods. The mRNA created via this method did not trigger an intracellular immune response via human IFN-gamma (hIFN-γ) or alpha (hIFN-α) release, thus circumventing the use of suppressors. Resulting mRNA and protein were expressed at high levels for over 48h, thus obviating daily transfections. Using this method, we demonstrated swift activation of pluripotency associated genes in human fibroblasts. Low oxygen conditions further facilitated colony formation. Differentiation into different germ layers was confirmed via teratoma assay. Reprogramming with non-synthetic mRNA holds great promise for safe generation of iPSCs of human origin. Using the protocols described herein we hope to make this method more accessible to other groups as a fast, inexpensive, and non-viral reprogramming approach. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  1. Structural determination of importin alpha in complex with beak and feather disease virus capsid nuclear localization signal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patterson, Edward I.; EH Graham Centre for Agricultural Innovation; Dombrovski, Andrew K.

    2013-09-06

    Highlights: •Circovirus capsid proteins contain large nuclear localization signals (NLS). •A method of nuclear import has not been elucidated. •Beak and feather disease virus (BFDV) capsid NLS was crystallized with importin α. •The structure showed BFDV NLS binding to the major site of importin α. •Result shows implications for mechanism of nuclear transport for all circoviruses. -- Abstract: Circoviruses represent a rapidly increasing genus of viruses that infect a variety of vertebrates. Replication requires shuttling viral molecules into the host cell nucleus, a process facilitated by capsid-associated protein (Cap). Whilst a nuclear localization signal (NLS) has been shown to mediatemore » nuclear translocation, the mode of nuclear transport remains to be elucidated. To better understand this process, beak and feather disease virus (BFDV) Cap NLS was crystallized with nuclear import receptor importin-α (Impα). Diffraction yielded structural data to 2.9 Å resolution, and the binding site on both Impα and BFDV Cap NLS were well resolved. The binding mechanism for the major site is likely conserved across circoviruses as supported by the similarity of NLSs in circovirus Caps. This finding illuminates a crucial step for infection of host cells by this viral family, and provides a platform for rational drug design against the binding interface.« less

  2. Quantitative analysis of sleep EEG microstructure in the time-frequency domain.

    PubMed

    De Carli, Fabrizio; Nobili, Lino; Beelke, Manolo; Watanabe, Tsuyoshi; Smerieri, Arianna; Parrino, Liborio; Terzano, Mario Giovanni; Ferrillo, Franco

    2004-06-30

    A number of phasic events influence sleep quality and sleep macrostructure. The detection of arousals and the analysis of cyclic alternating patterns (CAP) support the evaluation of sleep fragmentation and instability. Sixteen polygraphic overnight recordings were visually inspected for conventional Rechtscaffen and Kales scoring, while arousals were detected following the criteria of the American Sleep Disorders Association (ASDA). Three electroencephalograph (EEG) segments were associated to each event, corresponding to background activity, pre-arousal period and arousal. The study was supplemented by the analysis of time-frequency distribution of EEG within each subtype of phase A in the CAP. The arousals were characterized by the increase of alpha and beta power with regard to background. Within NREM sleep most of the arousals were preceded by a transient increase of delta power. The time-frequency evolution of the phase A of the CAP sequence showed a strong prevalence of delta activity during the whole A1, but high amplitude delta waves were found also in the first 2/3 s of A2 and A3, followed by desynchronization. Our results underline the strict relationship between the ASDA arousals, and the subtype A2 and A3 within the CAP: in both the association between a short sequence of transient slow waves and the successive increase of frequency and decrease of amplitude characterizes the arousal response.

  3. The Elbmarsch leukemia cluster: are there conceptual limitations in controlling immission from nuclear establishments in Germany?

    PubMed

    Schmitz-Feuerhake, I; Dieckmann, H; Hoffmann, W; Lengfelder, E; Pflugbeil, S; Stevenson, A F

    2005-11-01

    The childhood leukemia cluster in the proximity of the German nuclear establishments of Geesthacht is unique in its spatial and temporal concentration. After a steep increase in cases in 1990, the cluster continues to show a significant increase up to the present. Early investigations of blood samples from a casual sample of local residents showed an increase in dicentric chromosomes in lymphocytes, indicating exposure exceeding dose limits. Analyses of the immission data revealed several unexpected deliveries of fission and activation products in the environment but provided no explanation of the source. Because of the observed overdispersion of dicentric chromosomes in cells, the idea of a contribution by densely ionizing emitters was compelling. The routine programs, however, do not include alpha emitters. These were measured in specific studies that proved contamination by transuranic nuclides. As shown in the present investigation, routine environmental surveillance programs support the occurrence of an accidental event near Geesthacht in September 1986. Until now, neither the cause nor the complete scenario of the activity release could be established. The ongoing discussion highlights limitations in the immission-control concept, which is predominantly based on gamma-radiation monitoring.

  4. Review of Gallium-68 PSMA PET/CT Imaging in the Management of Prostate Cancer

    PubMed Central

    Lenzo, Nat P.; Meyrick, Danielle; Turner, J. Harvey

    2018-01-01

    Over 90% of prostate cancers over-express prostate specific membrane antigen (PSMA) and these tumor cells may be accurately targeted for diagnosis by 68Ga-PSMA-positron emission tomography/computed tomography (68Ga-PSMA-PET/CT) imaging. This novel molecular imaging modality appears clinically to have superseded CT, and appears superior to MR imaging, for the detection of metastatic disease. 68Ga-PSMA PET/CT has the ability to reliably stage prostate cancer at presentation and can help inform an optimal treatment approach. Novel diagnostic applications of 68Ga-PSMA PET/CT include guiding biopsy to improve sampling accuracy, and guiding surgery and radiotherapy. In addition to facilitating the management of metastatic castrate resistant prostate cancer (mCRPC), 68Ga-PSMA can select patients who may benefit from targeted systemic radionuclide therapy. 68Ga-PSMA is the diagnostic positron-emitting theranostic pair with the beta emitter Lutetium-177 PSMA (177Lu-PSMA) and alpha-emitter Actinium-225 PSMA (225Ac-PSMA) which can both be used to treat PSMA-avid metastases of prostate cancer in the molecular tumor-targeted approach of theranostic nuclear oncology. PMID:29439481

  5. Direct evidence for Lyboldsymbol{alpha } depletion in the protocluster core

    NASA Astrophysics Data System (ADS)

    Shimakawa, Rhythm; Kodama, Tadayuki; Hayashi, Masao; Tanaka, Ichi; Matsuda, Yuichi; Kashikawa, Nobunari; Shibuya, Takatoshi; Tadaki, Ken-ichi; Koyama, Yusei; Suzuki, Tomoko L.; Yamamoto, Moegi

    2017-06-01

    We have carried out panoramic Lyα narrow-band imaging with Suprime-Cam on Subaru towards the known protocluster USS1558-003 at z = 2.53. Our previous narrow-band imaging in the near-infrared identified multiple dense groups of Hα emitters (HAEs) within the protocluster. We have now identified the large-scale structures across a ˜50 comoving Mpc scale traced by Lyα emitters (LAEs) in which the protocluster traced by the HAEs is embedded. On a smaller scale, however, there are remarkably few LAEs in the regions of HAE overdensities. Moreover, the stacking analyses of the images show that HAEs in higher-density regions show systematically lower escape fractions of Lyα photons than those of HAEs in lower-density regions. These phenomena may be driven by the extra depletion of Lyα emission lines along our line of sight by more intervening cold circumgalactic/intergalactic medium and/or dust in the dense core. We also caution that all the previous high-z protocluster surveys using LAEs as tracers would have largely missed galaxies in the very dense cores of the protoclusters where we would expect to see any early environmental effects.

  6. Multi-wavelength Radio Continuum Emission Studies of Dust-free Red Giants

    NASA Technical Reports Server (NTRS)

    O'Gorman, Eamon; Harper, Graham M.; Brown, Alexander; Dranke, Stephen; Richards, Anita M. S.

    2013-01-01

    Multi-wavelength centimeter continuum observations of non-dusty, non-pulsating K spectral-type red giants directly sample their chromospheres and wind acceleration zones. Such stars are feeble emitters at these wavelengths, however, and previous observations have provided only a small number of modest signal-to-noise measurements slowly accumulated over three decades. We present multi-wavelength Karl G. Jansky Very Large Array thermal continuum observations of the wind acceleration zones of two dust-free red giants, Arcturus (alpha Boo: K2 III) and Aldebaran (alpha Tau: K5 III). Importantly, most of our observations of each star were carried out over just a few days, so that we obtained a snapshot of the different stellar atmospheric layers sampled at different wavelengths, independent of any long-term variability. We report the first detections at several wavelengths for each star including a detection at 10 cm (3.0 GHz: S band) for both stars and a 20 cm (1.5 GHz: L band) detection for alpha Boo. This is the first time single (non-binary) luminosity class III red giants have been detected at these continuum wavelengths. Our long-wavelength data sample the outer layers of alpha Boo's atmosphere where its wind velocity is approaching (or possibly has reached) its terminal value and the ionization balance is becoming frozen-in. For alpha Tau, however, our long-wavelength data are still sampling its inner atmosphere, where the wind is still accelerating probably due to its lower mass-loss rate. We compare our data with published semi-empirical models based on ultraviolet data, and the marked deviations highlight the need for new atmospheric models to be developed. Spectral indices are used to discuss the possible properties of the stellar atmospheres, and we find evidence for a rapidly cooling wind in the case of alpha Boo. Finally, we develop a simple analytical wind model for alpha Boo based on our new long-wavelength flux measurements.

  7. DIFFUSE Ly{alpha} EMITTING HALOS: A GENERIC PROPERTY OF HIGH-REDSHIFT STAR-FORMING GALAXIES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steidel, Charles C.; Bogosavljevic, Milan; Shapley, Alice E.

    2011-08-01

    Using a sample of 92 UV continuum-selected, spectroscopically identified galaxies with (z) = 2.65, all of which have been imaged in the Ly{alpha} line with extremely deep narrow-band imaging, we examine galaxy Ly{alpha} emission profiles to very faint surface brightness limits. The galaxy sample is representative of spectroscopic samples of Lyman break galaxies (LBGs) at similar redshifts in terms of apparent magnitude, UV luminosity, inferred extinction, and star formation rate and was assembled without regard to Ly{alpha} emission properties. Approximately 45% (55%) of the galaxy spectra have Ly{alpha} appearing in net absorption (emission), with {approx_equal} 20% satisfying commonly used criteriamore » for the identification of 'Ly{alpha} emitters' (LAEs; W{sub 0}(Ly{alpha}) {>=} 20 A). We use extremely deep stacks of rest-UV continuum and continuum-subtracted Ly{alpha} images to show that all sub-samples exhibit diffuse Ly{alpha} emission to radii of at least 10'' ({approx}80 physical kpc). The characteristic exponential scale lengths for Ly{alpha} line emission exceed that of the {lambda}{sub 0} = 1220 A UV continuum light by factors of {approx}5-10. The surface brightness profiles of Ly{alpha} emission are strongly suppressed relative to the UV continuum light in the inner few kpc, by amounts that are tightly correlated with the galaxies' observed spectral morphology; however, all galaxy sub-subsamples, including that of galaxies for which Ly{alpha} appears in net absorption in the spectra, exhibit qualitatively similar diffuse Ly{alpha} emission halos. Accounting for the extended Ly{alpha} emission halos, which generally would not be detected in the slit spectra of individual objects or with typical narrow-band Ly{alpha} imaging, increases the total Ly{alpha} flux (and rest equivalent width W{sub 0}(Ly{alpha})) by an average factor of {approx}5, and by a much larger factor for the 80% of LBGs not classified as LAEs. We argue that most, if not all, of the observed Ly{alpha} emission in the diffuse halos originates in the galaxy H II regions but is scattered in our direction by H I gas in the galaxy's circum-galactic medium. The overall intensity of Ly{alpha} halos, but not the surface brightness distribution, is strongly correlated with the emission observed in the central {approx}1''-more luminous halos are observed for galaxies with stronger central Ly{alpha} emission. We show that whether or not a galaxy is classified as a giant 'Ly{alpha} blob' (LAB) depends sensitively on the Ly{alpha} surface brightness threshold reached by an observation. Accounting for diffuse Ly{alpha} halos, all LBGs would be LABs if surveys were sensitive to 10 times lower Ly{alpha} surface brightness thresholds; similarly, essentially all LBGs would qualify as LAEs.« less

  8. Passive radon/thoron personal dosimeter using an electrostatic collector and a diffused-junction detector

    NASA Astrophysics Data System (ADS)

    Bigu, J.; Raz, R.

    1985-01-01

    A solid-state alpha dosimeter has been designed and tested suitable for personal and environmental radon/thoron monitoring. The dosimeter basically consists of an electrostatic collector and an alpha-particle counting system with spectroscopy capabilities. The sensitive volume (˜20 cm3) of the electrostatic collector consists of a cylindrically shaped metal wire screen and a diffused-junction silicon alpha-detector covered with a thin aluminized Mylar sheet. A dc voltage (˜500 V) is applied between the wire screen and the Mylar sheet, with the latter held at negative potential relative to the former. Data can be retrieved during or after sampling by means of a microcomputer (Epson HX20) via a RS-232 communication interface unit. The dosimeter has been calibrated in a large (26 m3) radon/thoron test facility. A linear relationship was found between the dosimeter's alpha-count and both radon gas concentration and radon daughter working level. The dosimeter is mounted on top of an ordinary miner's cap lamp battery and is ideally suited for personal monitoring in underground uranium mines and other working areas. The dosimeter presented here is a considerably improved version of an earlier prototype.

  9. Prevalence of type I sensitization to alpha-gal in forest service employees and hunters.

    PubMed

    Fischer, J; Lupberger, E; Hebsaker, J; Blumenstock, G; Aichinger, E; Yazdi, A S; Reick, D; Oehme, R; Biedermann, T

    2017-10-01

    The production of IgE molecules specific to the carbohydrate galactose-α-1,3-galactose (alpha-gal) is known to induce delayed anaphylaxis against mammalian meat. Tick bites constitute the primary sensitization source, as ticks transfer alpha-gal in their saliva to a host during a bite. The reported prevalence of alpha-gal-specific IgE (alpha-gal-sIgE) positivity varies between different populations from diverse geographic regions. To investigate the prevalence of alpha-gal-sIgE positivity in a population of forest service employees who are highly exposed to ticks in comparison with a residential population and a historic sample. A cross-sectional study evaluating 300 forest service employees and hunters from southwest Germany was performed. Alpha-gal-sIgE levels were assessed by ImmunoCAP assay. The prevalence of alpha-gal-sIgE-positive individuals was compared with a matched cohort composed of a residential population and blood samples from forest service employees collected 15 years ago. In the study population, the prevalence of alpha-gal-sIgE-positive (≥0.10 kU A /L) individuals was 35.0%, whereas the prevalence of individuals with alpha-gal-sIgE levels ≥0.35 kU A /L was 19.3%. Alpha-gal-sIgE positivity was associated with total IgE levels and recent tick bites. Mammalian meat-induced delayed anaphylaxis was found in 8.6% of the participants with alpha-gal-sIgE levels ≥0.35 kU A /L. For forest service employees and hunters, the odds ratio for alpha-gal-sIgE positivity was 2.48 compared to the residential population. The prevalence of alpha-gal-sIgE positivity in the current and historic cohort was comparable. Forest service employees and hunters compose a population with a high prevalence of alpha-gal-sIgE positivity and carry a considerable risk of red meat allergy. © 2017 EAACI and John Wiley and Sons A/S. Published by John Wiley and Sons Ltd.

  10. Revealing the X-Ray Emission Processes of Old Rotation-Powered Pulsars: XMM-Newton Observations of PSR B0950+08, PSR B0823+26 and PSR J2043+2740

    NASA Technical Reports Server (NTRS)

    Becker, Werner; Weisskopf, Martin C.; Tenant, Allyn F.; Jessmer, Axel; Zhang, Shiang N.

    2004-01-01

    We have completed part of a program to study the X-ray emission properties of old rotation-powered pulsars with XMM-Newton in order to probe and identify the origin of their X radiation. The X-ray emission from these old pulsars is largely dominated by non-thermal processes. None of the observed spectra required adding a thermal component consisting of either a hot polar cap or surface cooling emission to model the data. The energy spectrum of PSR B0950+08 is best described by a single power law of photon-index alpha = 1.93(sup +0.14)(sub -0.12). Three-sigma temperature upper limits for possible contributions from a heated polar cap or the whole neutron star surface are T(sup infinity)(sub pc) < 0.87 x 10(exp 6) K and T(sup infinity)(sub s) < 0.48 x 10(exp 6) K, respectively. We also find that the X-ray emission from PSR B0950+08 is pulsed with two peaks per rotation period. The phase separation between the two X-ray peaks is approx. 144 deg (maximum to maximum) which is similar to the pulse peak separation observed in the radio band at 1.4 GHz. The fraction of X-ray pulsed photons is approx. 30%. A phase resolved spectral analysis confirms the nonthermal nature of the pulsed emission and finds power law slopes of alpha = 2.4(sup +0.52)(sub -0.42) and alpha = 1.93(sup +0.29)(sub -0.24) for the pulse peaks P1 and P2, respectively. The spectral emission properties observed for PSR B0823+26 are similar to those of PSR B0950+08. Its energy spectrum is very well described by a single power law with photon-index alpha = 2.5(sup +0.52)(sub -0.24. Three-sigma temperature upper limits for thermal contributions from a hot polar cap or from the entire neutron star surface are T(sup infinity)(sub pc) < 1.17 x 10(exp 6) K and T(sup infinity)(sub s) < 0.5 x 10(exp 6) K, respectively. There is evidence for pulsed X-ray emission at the - 97% confidence level with a pulsed fraction of 49 +/- 22%. For PSR 52043+2740 we report the first detection of X-ray emission. A power law spectrum, or a combination of a thermal and a power law spectrum all yield acceptable descriptions of its X-ray spectrum. No X-ray pulses are detected from PSR J2043+2740 but the sensitivity is low - the 2-sigma pulsed fraction upper limit is 57% assuming a sinusoidal pulse profile.

  11. Link between microstability and macrostability of plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Litwin, C.

    A mechanism linking high-frequency microinstabilities and the low-frequencymacrostability is proposed. The coupling is provided by the time-averagedforce, ponderomotive force, of unstable high-frequency waves. Two specificexamples of this phenomenon are discussed. It is shown that an..cap alpha..-particle loss-cone instability stabilizes the flute mode of anignited, axisymmetric mirror plasma. In tokamaks, the ion-whistler instability,driven by an anisotropic population of energetic particles, stabilizes theinternal kink mode for JET range of parameters.

  12. Coupling ligand recognition to protein folding in an engineered variant of rabbit ileal lipid binding protein.

    PubMed

    Kouvatsos, Nikolaos; Meldrum, Jill K; Searle, Mark S; Thomas, Neil R

    2006-11-28

    We have engineered a variant of the beta-clam shell protein ILBP which lacks the alpha-helical motif that caps the central binding cavity; the mutant protein is sufficiently destabilised that it is unfolded under physiological conditions, however, it unexpectedly binds its natural bile acid substrates with high affinity forming a native-like beta-sheet rich structure and demonstrating strong thermodynamic coupling between ligand binding and protein folding.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, W.F.; Martinell, J.; Whitney, J.B. III

    The group of diseases called the thalassemias is the largest single-gene health problem in the world according the World Health Organization. The thalassemias are lethal hereditary anemias in which the infants cannot make their own blood. Three mouse mutants are shown to be models of the human disease ..cap alpha..-thalassemia. However, since an additional gene is affected, these mutants represent a particularly severe condition in which death occurs in the homozygous embryo even before globin genes are activated. Phenotypic and genotypic characteristics are described. (ACR)

  14. In-vivo measurement of lithium in the brain and other organs

    DOEpatents

    Vartsky, D.; Wielopolski, L.; LoMonte, A.F.; Ellis, K.J.; Cohn, S.H.

    1983-08-26

    An in-vivo method of measurement of the amount of lithium present in tissue and organs of breathing animals is described. The basis for the technique is the lithium-1 neutron interaction - /sup 6/Li(n,..cap alpha..)T. The lithium is irradiated with thermal neutrons to produce tritium atoms. The tritium diffuses into the tissues and is exhaled. By measuring the amount of tritium exhaled, the lithium concentration in the irradiated zone is determined.

  15. Investigations in the ionosphere on Kosmos 378. VII. Simultaneous ground-based and satellite measurements of the parameters of the high latitude ionosphere

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Afonin, V.V.; Gdalevich, G.L.; Gubskii, V.F.

    1975-01-01

    The parameters of the high-latitude ionospheric plasma at night were measured simultaneously in the winter of 1970 by Kosmos 378 and by the ground-based observatory at Noril'sk. A comparison of ground-based and satellite measurements showed good agreement of n/sub e/ when the Chapman approximation for the ..cap alpha..-layer and Jacchia's 1971 model of the upper atmosphere are used.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Akhtar, R.A.; Abdel-Latif, A.A.

    Muscarinic cholinergic and ..cap alpha../sub 1/-adrenergic agonists provoke hydrolysis of PIP/sub 2/ into diacylglycerol (DG) and inositol trisphosphate (IP/sub 3/) in a wide variety of tissue. Recently, IP/sub 3/ has been shown to mobilize Ca/sup 2 +/ from ER in several permeabilized tissue preparations. Although rabbit cornea is enriched in ACh and NE, the physiological function of these neurotransmitters is unclear. The present studies were initiated to determine the effects of cholinergic and adrenergic agonists on PIP/sub 2/ turnover in the cornea. Addition of ACh or NE (50 ..mu..M each) to the /sup 32/P-labeled corneas for 10 min decreased themore » radioactivity in PIP/sub 2/ by 33 and 36%, and increased the radioactivity in phosphatidic acid by 72 and 52%, respectively. When the corneas were labeled with myo-(/sup 3/H)inositol, ACh and NE increased the accumulation of IP/sub 3/ by 92 and 48%, respectively. The effects of ACh and NE on phospholipid labeling and IP/sub 3/ accumulation were specifically inhibited by atropine (10 ..mu..M) and prazosin (10 ..mu..M), respectively. The data suggest the presence of muscarinic cholinergic and ..cap alpha../sub 1/-adrenergic receptors in the rabbit cornea. Furthermore, activation of these receptors leads to cleavage of PIP/sub 2/ into DG and IP/sub 3/ which may function as second messengers in this tissue.« less

  17. Prevalence of. cap alpha. /sub 1/-antitrypsin heterozygotes (Pi MZ) in patients with obstructive pulmonary disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shigeoka, J.W.; Hall, W.J.; Hyde, R.W.

    1976-01-01

    An increased incidence of intermediate deficiency of serum ..cap alpha../sub 1/-antitrypsin resulting from Pi phenotype MZ has been reported in patients with chronic obstructive pulmonary disease (COPD) by some laboratories but not confirmed by others. Prevalence of Pi MZ was determined in patients with COPD among 502 subjects referred to a pulmonary function testing laboratory in a region with low concentrations of air pollutants. Control prevalences were obtained from 930 randomly selected subjects in the same community as well as from patients without COPD referred to the laboratory. Depending on criteria used to define COPD, 155 to 306 subjects hadmore » COPD. Pi MZ prevalence in subjects with COPD varied from 1.5 to 4 times the prevalence in the community control group and in the patients without COPD. This difference approached significance or was significant. Because Pi MZ was present in only 3.5 to 4.5% of patients with COPD, Pi MZ is not a major factor in the etiology of COPD in this community. The higher incidence of Pi MZ in patients with COPD reported by other investigators may be explained by small sample size, bias in selection of study or control population groups, or the development of COPD from interaction between Pi MZ and air pollutants or other factors not present in this community.« less

  18. ROAM mutations causing increased expression of yeast genes: their activation by signals directed toward conjugation functions and their formation by insertion of tyl repetitive elements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Errede, B.; Cardillo, T.S.; Wever, G.

    1980-01-01

    Mechanisms available to eukaryotic organisms for the coordinate regulation of gene expression are being examined by genetic and biochemical characterization of an unusual mutation, CYC7-H2, which causes overproduction of iso-2-cytochrome c in the yeast Saccharomyces cerevisiae. The CYC7-H2 mutation causes approximately a twenty fold overproduction of iso-2-cytochrome c in haploid strains but only a one to four fold overproduction in MATa/MAT..cap alpha.. diploid strains. This regulation of overproduction has been characterized as a response to signals controlling conjugation in yeast. The CYC7-H2 mutation is closely related to other regulatory mutations occurring at the cargA, cargB and DUR1,2 loci which aremore » the structural genes for arginase, ornithine transaminase and urea amidolyase, respectively. Similar to the CYC7-H2 mutation, the mutations designated cargA/sup +/O/sup h/, cargB/sup +/O/sup h/ and durO/sup h/ cause constitutive production of their respective gene products at much lower levels in MATa/MAT..cap alpha.. diploid strains than in the corresponding haploid strains. Observations characterizing the regulation of overproduction in the CYC7-H2 mutant are presented with the additional and parallel observations for the O/sup h/ mutants.« less

  19. Proteases induce secretion of collagenase and plasminogen activator by fibroblasts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Werb, Z.; Aggeler, J.

    1978-04-01

    We have observed that treatment of rabbit synovial fibroblasts with proteolytic enzymes can induce secretion of collagenase (EC 3.4.24.7) and plasminogen activator (EC 3.4.21.-). Cells treated for 2 to 24 hr with plasmin, trypsin, chymotrypsin, pancreatic elastase, papain, bromelain, thermolysin, or ..cap alpha..-protease but not with thrombin or neuraminidase secreted detectable amounts of collagenase within 16 to 48 hr. Treatment of fibroblasts with trypsin also induced secretion of plasminogen activator. Proteases initiated secretion of collagenase (up to 20 units per 10/sup 6/ cells per 24 hr) only when treatment produced decreased cell adhesion. Collagenase production did not depend on continuedmore » presence of proteolytic activity or on subsequent cell adhesion, spreading, or proliferation. Routine subculturing with crude trypsin also induced collagenase secretion by cells. Secretion of collagenase was prevented and normal spreading was obtained if the trypsinized cells were placed into medium containing fetal calf serum. Soybean trypsin inhibitor, ..cap alpha../sub 1/-antitrypsin, bovine serum albumin, collagen, and fibronectin did not inhibit collagenase production. Although proteases that induced collagenase secretion also removed surface glycoprotein, the kinetics of induction of cell protease secretion were different from those for removal of fibronectin. Physiological inducers of secretion of collagenase and plasminogen activator by cells have not been identified. These results suggest that extracellular proteases in conjunction with plasma proteins may govern protease secretion by cells.« less

  20. Preliminary Work Toward a Transuranic Activity Estimation Method for Rapid Discrimination of Anthropogenic from Transuranic Activity in Alpha Air Samples

    DOE PAGES

    Cope, S. Joseph; Hayes, Robert B.

    2018-03-01

    Radon ( 222Rn) and thoron ( 220Rn) progeny (primarily bismuth and polonium) are known interferents when rapid evaluation of transuranic content on air filters is of interest. These complexities stem from the overlapping energies of the progeny alpha particles onto the transuranic region of interest (3–5.5 MeV) where naturally-occurring alpha emitters can overwhelm the spectra. Due to the immediacy of the alpha counting methods employed, coupled with the half-life of thoron progeny dominated by 212Pb (t 1/2=10.6 h), a conservative transuranic activity estimate with rigorous uncertainty is being sought. A successful transuranic activity estimation method will incorporate any thoron progenymore » present on the filter providing 95% confidence decision levels in which a filter may be evaluated for emergency response applications. Twenty-three pairs of samples of various duration having no transuranic content were taken over a 2-mo period. The resulting filters were counted in a time series before non-linear least squares decay curve fitting was applied to the decay profile. For the samples considered, a transuranic activity estima-tor decision level was determined at 0.2 Bq for the given geographic location and months analyzed. In conclusion, validation of this method for other seasonal and geographic regions could provide enhanced emergency response capability when the presence of transuranic activity is suspected.« less

  1. Preliminary Work Toward a Transuranic Activity Estimation Method for Rapid Discrimination of Anthropogenic from Transuranic Activity in Alpha Air Samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cope, S. Joseph; Hayes, Robert B.

    Radon ( 222Rn) and thoron ( 220Rn) progeny (primarily bismuth and polonium) are known interferents when rapid evaluation of transuranic content on air filters is of interest. These complexities stem from the overlapping energies of the progeny alpha particles onto the transuranic region of interest (3–5.5 MeV) where naturally-occurring alpha emitters can overwhelm the spectra. Due to the immediacy of the alpha counting methods employed, coupled with the half-life of thoron progeny dominated by 212Pb (t 1/2=10.6 h), a conservative transuranic activity estimate with rigorous uncertainty is being sought. A successful transuranic activity estimation method will incorporate any thoron progenymore » present on the filter providing 95% confidence decision levels in which a filter may be evaluated for emergency response applications. Twenty-three pairs of samples of various duration having no transuranic content were taken over a 2-mo period. The resulting filters were counted in a time series before non-linear least squares decay curve fitting was applied to the decay profile. For the samples considered, a transuranic activity estima-tor decision level was determined at 0.2 Bq for the given geographic location and months analyzed. In conclusion, validation of this method for other seasonal and geographic regions could provide enhanced emergency response capability when the presence of transuranic activity is suspected.« less

  2. Alpha-particle-induced cancer in humans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mays, C.W.

    Updated information is given on alpha-particle-induced cancer in persons internally exposed to 222Rn progeny, Thorotrast, long-lived 226Ra and 228Ra, and short-lived 224Ra. The lung cancer risk to persons breathing 222Rn progeny in the indoor air of offices, schools, and homes is of increasing concern. About half of the recent deaths among the German Thorotrast patients have been from liver cancer. Animal studies indicate that the liver cancer risk from Thorotrast is mainly from its radioactivity and that the risk coefficient for the Thorotrast patients can be used provisionally for other alpha emitters in the human liver. Six skeletal cancers havemore » occurred in persons with average skeletal doses between 0.85 and 11.8 Gy from 226Ra and 228Ra. In the low-dose German 224Ra patients, two skeletal sarcomas have occurred at about 0.7 Gy compared to about six cases predicted by results from 224Ra patients at higher doses. The minimal appearance time for radiation-induced bone sarcomas in humans is about 4 y. Following brief irradiation, the vast majority of induced bone sarcomas are expressed by about 30 y. Recent evidence against the practical threshold hypothesis is given. With the downward revision of neutron doses to the atomic-bomb survivors, the follow-up of persons exposed to alpha particles may be the best opportunity to evaluate directly the effects of high LET radiation on humans. 90 references.« less

  3. Apparatus and method for quantitative assay of generic transuranic wastes from nuclear reactors

    DOEpatents

    Caldwell, J.T.; Kunz, W.E.; Atencio, J.D.

    1982-03-31

    A combination of passive and active neutron measurements which yields quantitative information about the isotopic composition of transuranic wastes from nuclear power or weapons material manufacture reactors is described. From the measurement of prompt and delayed neutron emission and the incidence of two coincidentally emitted neutrons from induced fission of fissile material in the sample, one can quantify /sup 233/U, /sup 235/U and /sup 239/Pu isotopes in waste samples. Passive coincidence counting, including neutron multiplicity measurement and determination of the overall passive neutron flux additionally enables the separate quantitative evaluation of spontaneous fission isotopes such as /sup 240/Pu, /sup 244/Cm and /sup 252/Cf, and the spontaneous alpha particle emitter /sup 241/Am. These seven isotopes are the most important constituents of wastes from nuclear power reactors and once the mass of each isotope present is determined by the apparatus and method of the instant invention, the overall alpha particle activity can be determined to better than 1 nCi/g from known radioactivity data. Therefore, in addition to the quantitative analysis of the waste sample useful for later reclamation purposes, the alpha particle activity can be determined to decide whether permanent low-level burial is appropriate for the waste sample.

  4. Apparatus and method for quantitative assay of generic transuranic wastes from nuclear reactors

    DOEpatents

    Caldwell, John T.; Kunz, Walter E.; Atencio, James D.

    1984-01-01

    A combination of passive and active neutron measurements which yields quantitative information about the isotopic composition of transuranic wastes from nuclear power or weapons material manufacture reactors is described. From the measurement of prompt and delayed neutron emission and the incidence of two coincidentally emitted neutrons from induced fission of fissile material in the sample, one can quantify .sup.233 U, .sup.235 U and .sup.239 Pu isotopes in waste samples. Passive coincidence counting, including neutron multiplicity measurement and determination of the overall passive neutron flux additionally enables the separate quantitative evaluation of spontaneous fission isotopes such as .sup.240 Pu, .sup.244 Cm and .sup.252 Cf, and the spontaneous alpha particle emitter .sup.241 Am. These seven isotopes are the most important constituents of wastes from nuclear power reactors and once the mass of each isotope present is determined by the apparatus and method of the instant invention, the overall alpha particle activity can be determined to better than 1 nCi/g from known radioactivity data. Therefore, in addition to the quantitative analysis of the waste sample useful for later reclamation purposes, the alpha particle activity can be determined to decide whether "permanent" low-level burial is appropriate for the waste sample.

  5. Linear Collider Test Facility: Twiss Parameter Analysis at the IP/Post-IP Location of the ATF2 Beam Line

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bolzon, Benoit; /Annecy, LAPP; Jeremie, Andrea

    2012-07-02

    At the first stage of the ATF2 beam tuning, vertical beam size is usually bigger than 3 {micro}m at the IP. Beam waist measurements using wire scanners and a laser wire are usually performed to check the initial matching of the beam through to the IP. These measurements are described in this paper for the optics currently used ({beta}{sub x} = 4cm and {beta}{sub y} = 1mm). Software implemented in the control room to automate these measurements with integrated analysis is also described. Measurements showed that {beta} functions and emittances were within errors of measurements when no rematching and couplingmore » corrections were done. However, it was observed that the waist in the horizontal (X) and vertical (Y) plane was abnormally shifted and simulations were performed to try to understand these shifts. They also showed that multiknobs are needed in the current optics to correct simultaneously {alpha}{sub x}, {alpha}{sub y} and the horizontal dispersion (D{sub x}). Such multiknobs were found and their linearity and orthogonality were successfully checked using MAD optics code. The software for these multiknobs was implemented in the control room and waist scan measurements using the {alpha}{sub y} knob were successfully performed.« less

  6. Approaching reionization from two directions: high-redshift Lyman-alpha emitters and local analogs

    NASA Astrophysics Data System (ADS)

    Bagley, Micaela

    2018-01-01

    The dark ages that followed the recombination of the universe ended with the appearance of metal-free stars and the subsequent formation of numerous low-mass, metal-poor galaxies. The collective ionizing background from these newly-forming galaxies is thought to be responsible for the reionization of the diffuse hydrogen in the intergalactic medium between redshifts 10 and 6.5. The progression of the reionization history depends on the nature of these first sources -- their number densities, luminosities, clustering, and production rates of ionizing photons -- which is currently the subject of considerable observational and theoretical efforts.I will present results of a two-pronged approach to studying the Epoch of Reionization: a systematic search for Lyman-alpha emitting galaxies at redshifts greater than 6, and an analysis of high S/N spectra of a sample of local galaxies that are potential analogs to those responsible for the reionization. Selected for their large [OIII]/[OII] ratios and high H-alpha equivalent widths, the local galaxies have very low masses and are consistent with photoionization by stars with effective temperatures of 10^5 K. Both the emission lines and continua of the spectra are spatially extended, allowing for an analysis of galaxy properties such as gas temperature, elemental abundance, and ionizing power at different radii.

  7. Mirrors in the PDB: left-handed alpha-turns guide design with D-amino acids.

    PubMed

    Annavarapu, Srinivas; Nanda, Vikas

    2009-09-22

    Incorporating variable amino acid stereochemistry in molecular design has the potential to improve existing protein stability and create new topologies inaccessible to homochiral molecules. The Protein Data Bank has been a reliable, rich source of information on molecular interactions and their role in protein stability and structure. D-amino acids rarely occur naturally, making it difficult to infer general rules for how they would be tolerated in proteins through an analysis of existing protein structures. However, protein elements containing short left-handed turns and helices turn out to contain useful information. Molecular mechanisms used in proteins to stabilize left-handed elements by L-amino acids are structurally enantiomeric to potential synthetic strategies for stabilizing right-handed elements with D-amino acids. Propensities for amino acids to occur in contiguous alpha(L) helices correlate with published thermodynamic scales for incorporation of D-amino acids into alpha(R) helices. Two backbone rules for terminating a left-handed helix are found: an alpha(R) conformation is disfavored at the amino terminus, and a beta(R) conformation is disfavored at the carboxy terminus. Helix capping sidechain-backbone interactions are found which are unique to alpha(L) helices including an elevated propensity for L-Asn, and L-Thr at the amino terminus and L-Gln, L-Thr and L-Ser at the carboxy terminus. By examining left-handed alpha-turns containing L-amino acids, new interaction motifs for incorporating D-amino acids into right-handed alpha-helices are identified. These will provide a basis for de novo design of novel heterochiral protein folds.

  8. Quantitative comparisons of cancer induction in humans by internally deposited radionuclides and external radiation.

    PubMed

    Harrison, J D; Muirhead, C R

    2003-01-01

    To compare quantitative estimates of lifetime cancer risk in humans for exposures to internally deposited radionuclides and external radiation. To assess the possibility that risks from radionuclide exposures may be underestimated. Risk estimates following internal exposures can be made for a small number of alpha-particle-emitting nuclides. (1) Lung cancer in underground miners exposed by inhalation to radon-222 gas and its short-lived progeny. Studies of residential (222)Rn exposure are generally consistent with predictions from the miner studies. (2) Liver cancer and leukaemia in patients given intravascular injections of Thorotrast, a thorium-232 oxide preparation that concentrates in liver, spleen and bone marrow. (3) Bone cancer in patients given injections of radium-224, and in workers exposed occupationally to (226)Ra and (228)Ra, mainly by ingestion. (4) Lung cancer in Mayak workers exposed to plutonium-239, mainly by inhalation. Liver and bone cancers were also seen, but the dosimetry is not yet sufficiently good enough to provide quantitative estimates of risks. Comparisons can be made between risk estimates for radiation-induced cancer derived for radionuclide exposure and those derived for the A-bomb survivors, exposed mainly to low-LET (linear energy transfer) external radiation. Data from animal studies, using dogs and rodents, allow comparisons of cancer induction by a range of alpha- and beta-/gamma-emitting radionuclides. They provide information on relative biological effectiveness (RBE), dose-response relationships, dose-rate effects and the location of target cells for different malignancies. For lung and liver cancer, the estimated values of risk per Sv for internal exposure, assuming an RBE for alpha-particles of 20, are reasonably consistent with estimates for external exposure to low-LET radiation. This also applies to bone cancer when risk is calculated on the basis of average bone dose, but consideration of dose to target cells on bone surfaces suggests a low RBE for alpha-particles. Similarly, for leukaemia, the comparison of risks from alpha-irradiation ((232)Th and progeny) and external radiation suggest a low alpha RBE; this conclusion is supported by animal data. Risk estimates for internal exposure are dependent on the assumptions made in calculating dose. Account is taken of the distribution of radionuclides within tissues and the distribution of target cells for cancer induction. For the lungs and liver, the available human and animal data provide support for current assumptions. However, for bone cancer and leukaemia, it may be that changes are required. Bone cancer risk may be best assessed by calculating dose to a 50 micro m layer of marrow adjacent to endosteal (inner) bone surfaces rather than to a single 10 micro m cell layer as currently assumed. Target cells for leukaemia may be concentrated towards the centre of marrow cavities so that the risk of leukaemia from bone-seeking radionuclides, particularly alpha emitters, may be overestimated by the current assumption of uniform distribution of target cells throughout red bone marrow. The lifetime risk estimates considered here for exposure to internally deposited radionuclides and to external radiation are subject to uncertainties, arising from the dosimetric assumptions made, from the quality of cancer incidence and mortality data and from aspects of risk modelling; including variations in baseline rates between populations for some cancer types. Bearing in mind such uncertainties, comparisons of risk estimates for internal emitters and external radiation show good agreement for lung and liver cancers. For leukaemia, the available data suggest that the assumption of an alpha-particle RBE of 20 can result in overestimates of risk. For bone cancer, it also appears that current assumptions will overestimate risks from alpha-particle-emitting nuclides, particularly at low doses.

  9. NOx Emissions from Large Point Sources: Variability in Ozone Production, Resulting Health Damages and Economic Costs

    NASA Astrophysics Data System (ADS)

    Mauzerall, D. L.; Sultan, B.; Kim, N.; Bradford, D.

    2004-12-01

    We present a proof-of-concept analysis of the measurement of the health damage of ozone (O3) produced from nitrogen oxides (NOx = NO + NO2) emitted by individual large point sources in the eastern United States. We use a regional atmospheric model of the eastern United States, the Comprehensive Air Quality Model with Extensions (CAMx), to quantify the variable impact that a fixed quantity of NOx emitted from individual sources can have on the downwind concentration of surface O3, depending on temperature and local biogenic hydrocarbon emissions. We also examine the dependence of resulting ozone-related health damages on the size of the exposed population. The investigation is relevant to the increasingly widely used "cap and trade" approach to NOx regulation, which presumes that shifts of emissions over time and space, holding the total fixed over the course of the summer O3 season, will have minimal effect on the environmental outcome. By contrast, we show that a shift of a unit of NOx emissions from one place or time to another could result in large changes in the health effects due to ozone formation and exposure. We indicate how the type of modeling carried out here might be used to attach externality-correcting prices to emissions. Charging emitters fees that are commensurate with the damage caused by their NOx emissions would create an incentive for emitters to reduce emissions at times and in locations where they cause the largest damage.

  10. Comment on radiative magnetic energy shifts in hydrogen

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Calmet, J.; Grotch, H.; Owen, D.A.

    It is shown that the magnetic radiative energy shift derived from the relativistic-Lamb-shift expression of Erickson and Yennie reduces in the nonrelativistic limit to a formula given by Grotch and Hegstrom, which was derived starting from the nonrelativistic theory. This clears up a discrepancy between those two approaches. The corresponding correction to the g factor, which exists only for states with l not = 0, is estimated to be -0.24 ..cap alpha../sup 3/ for the 2P state of hydrogen.

  11. QUASARS PROBING QUASARS. IV. JOINT CONSTRAINTS ON THE CIRCUMGALACTIC MEDIUM FROM ABSORPTION AND EMISSION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hennawi, Joseph F.; Prochaska, J. Xavier, E-mail: xavier@ucolick.org

    2013-03-20

    We have constructed a sample of 29 close projected quasar pairs where the background quasar spectrum reveals absorption from optically thick H I gas associated with the foreground quasar. These unique sightlines allow us to study the quasar circumgalactic medium (CGM) in absorption and emission simultaneously, because the background quasar pinpoints large concentrations of gas where Ly{alpha} emission, resulting from quasar-powered fluorescence, resonant Ly{alpha} scattering, and/or cooling radiation, is expected. A sensitive search (1{sigma} surface-brightness limits of SB{sub Ly{alpha}}{approx_equal}3 Multiplication-Sign 10{sup -18} erg s{sup -1} cm{sup -2} arcsec{sup -2}) for diffuse Ly{alpha} emission in the environments of the foreground (predominantlymore » radio-quiet) quasars is conducted using Gemini/GMOS and Keck/LRIS slit spectroscopy. We fail to detect large-scale {approx}100 kpc Ly{alpha} emission, either at the location of the optically thick absorbers or in the foreground quasar halos, in all cases except a single system. We interpret these non-detections as evidence that the gas detected in absorption is shadowed from the quasar UV radiation due to obscuration effects, which are frequently invoked in unified models of active galactic nuclei. Small-scale R {approx}< 50 kpc extended Ly{alpha} nebulosities are detected in 34% of our sample, which are likely the high-redshift analogs of the extended emission-line regions (EELRs) commonly observed around low-redshift (z < 0.5) quasars. This may be fluorescent recombination radiation from a population of very dense clouds with a low covering fraction illuminated by the quasar. We also detect a compact high rest-frame equivalent width (W{sub Ly{alpha}} > 50 A) Ly{alpha}-emitter with luminosity L{sub Ly{alpha}} = 2.1 {+-} 0.32 Multiplication-Sign 10{sup 41} erg s{sup -1} at small impact parameter R = 134 kpc from one foreground quasar, and argue that it is more likely to result from quasar-powered fluorescence, than simply be a star-forming galaxy clustered around the quasar. Our observations imply that much deeper integrations with upcoming integral-field spectrometers such as MUSE and KCWI will be able to routinely detect a diffuse Ly{alpha} glow around bright quasars on scales R {approx} 100 kpc and thus directly image the CGM.« less

  12. Electron transfer from a carbon nanotube into vacuum under high electric fields

    NASA Astrophysics Data System (ADS)

    Filip, L. D.; Smith, R. C.; Carey, J. D.; Silva, S. R. P.

    2009-05-01

    The transfer of an electron from a carbon nanotube (CNT) tip into vacuum under a high electric field is considered beyond the usual one-dimensional semi-classical approach. A model of the potential energy outside the CNT cap is proposed in order to show the importance of the intrinsic CNT parameters such as radius, length and vacuum barrier height. This model also takes into account set-up parameters such as the shape of the anode and the anode-to-cathode distance, which are generically portable to any modelling study of electron emission from a tip emitter. Results obtained within our model compare well to experimental data. Moreover, in contrast to the usual one-dimensional Wentzel-Kramers-Brillouin description, our model retains the ability to explain non-standard features of the process of electron field emission from CNTs that arise as a result of the quantum behaviour of electrons on the surface of the CNT.

  13. Subaru studies of the cosmic dawn

    PubMed Central

    IYE, Masanori

    2011-01-01

    An overview on the current status of the census of the early Universe population is given. Observational surveys of high redshift objects provide direct opportunities to study the early epoch of the Universe. The target population included are Lyman Alpha Emitters (LAE), Lyman Break Galaxies (LBG), gravitationally lensed galaxies, quasars and gamma-ray bursts (GRB). The basic properties of these objects and the methods used to study them are reviewed. The present paper highlights the fact that the Subaru Telescope group made significant contributions in this field of science to elucidate the epoch of the cosmic dawn and to improve the understanding of how and when infant galaxies evolve into mature ones. PMID:22075759

  14. Monolithic multinozzle emitters for nanoelectrospray mass spectrometry

    DOEpatents

    Wang, Daojing [Daly City, CA; Yang, Peidong [Kensington, CA; Kim, Woong [Seoul, KR; Fan, Rong [Pasadena, CA

    2011-09-20

    Novel and significantly simplified procedures for fabrication of fully integrated nanoelectrospray emitters have been described. For nanofabricated monolithic multinozzle emitters (NM.sup.2 emitters), a bottom up approach using silicon nanowires on a silicon sliver is used. For microfabricated monolithic multinozzle emitters (M.sup.3 emitters), a top down approach using MEMS techniques on silicon wafers is used. The emitters have performance comparable to that of commercially-available silica capillary emitters for nanoelectrospray mass spectrometry.

  15. Asymmetrical field emitter

    DOEpatents

    Fleming, J.G.; Smith, B.K.

    1995-10-10

    A method is disclosed for providing a field emitter with an asymmetrical emitter structure having a very sharp tip in close proximity to its gate. One preferred embodiment of the present invention includes an asymmetrical emitter and a gate. The emitter having a tip and a side is coupled to a substrate. The gate is connected to a step in the substrate. The step has a top surface and a side wall that is substantially parallel to the side of the emitter. The tip of the emitter is in close proximity to the gate. The emitter is at an emitter potential, and the gate is at a gate potential such that with the two potentials at appropriate values, electrons are emitted from the emitter. In one embodiment, the gate is separated from the emitter by an oxide layer, and the emitter is etched anisotropically to form its tip and its asymmetrical structure. 17 figs.

  16. Monte Carlo calculation of the maximum therapeutic gain of tumor antivascular alpha therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Chen-Yu; Oborn, Bradley M.; Guatelli, Susanna

    Purpose: Metastatic melanoma lesions experienced marked regression after systemic targeted alpha therapy in a phase 1 clinical trial. This unexpected response was ascribed to tumor antivascular alpha therapy (TAVAT), in which effective tumor regression is achieved by killing endothelial cells (ECs) in tumor capillaries and, thus, depriving cancer cells of nutrition and oxygen. The purpose of this paper is to quantitatively analyze the therapeutic efficacy and safety of TAVAT by building up the testing Monte Carlo microdosimetric models. Methods: Geant4 was adapted to simulate the spatial nonuniform distribution of the alpha emitter {sup 213}Bi. The intraluminal model was designed tomore » simulate the background dose to normal tissue capillary ECs from the nontargeted activity in the blood. The perivascular model calculates the EC dose from the activity bound to the perivascular cancer cells. The key parameters are the probability of an alpha particle traversing an EC nucleus, the energy deposition, the lineal energy transfer, and the specific energy. These results were then applied to interpret the clinical trial. Cell survival rate and therapeutic gain were determined. Results: The specific energy for an alpha particle hitting an EC nucleus in the intraluminal and perivascular models is 0.35 and 0.37 Gy, respectively. As the average probability of traversal in these models is 2.7% and 1.1%, the mean specific energy per decay drops to 1.0 cGy and 0.4 cGy, which demonstrates that the source distribution has a significant impact on the dose. Using the melanoma clinical trial activity of 25 mCi, the dose to tumor EC nucleus is found to be 3.2 Gy and to a normal capillary EC nucleus to be 1.8 cGy. These data give a maximum therapeutic gain of about 180 and validate the TAVAT concept. Conclusions: TAVAT can deliver a cytotoxic dose to tumor capillaries without being toxic to normal tissue capillaries.« less

  17. Prebiotic syntheses of vitamin coenzymes: II. Pantoic acid, pantothenic acid, and the composition of coenzyme A

    NASA Technical Reports Server (NTRS)

    Miller, S. L.; Schlesinger, G.

    1993-01-01

    Pantoic acid can by synthesized in good prebiotic yield from isobutyraldehyde or alpha-ketoisovaleric acid + H2CO + HCN. Isobutyraldehyde is the Strecker precursor to valine and alpha-ketoisovaleric acid is the valine transamination product. Mg2+ and Ca2+ as well as several transition metals are catalysts for the alpha-ketoisovaleric acid reaction. Pantothenic acid is produced from pantoyl lactone (easily formed from pantoic acid) and the relatively high concentrations of beta-alanine that would be formed on drying prebiotic amino acid mixtures. There is no selectivity for this reaction over glycine, alanine, or gamma-amino butyric acid. The components of coenzyme A are discussed in terms of ease of prebiotic formation and stability and are shown to be plausible choices, but many other compounds are possible. The gamma-OH of pantoic acid needs to be capped to prevent decomposition of pantothenic acid. These results suggest that coenzyme A function was important in the earliest metabolic pathways and that the coenzyme A precursor contained most of the components of the present coenzyme.

  18. Origin of ice-rafted debris: Pleistocene paleoceanography in the western Arctic Ocean

    NASA Astrophysics Data System (ADS)

    Bischof, Jens; Clark, David L.; Vincent, Jean-Serge

    1996-12-01

    The composition of Pleistocene ice-rafted debris (IRD) >250 µm was analyzed quantitatively by grain counting in five sediment cores from the western central Arctic Ocean and compared with the composition of till clasts from NW Canada in order to determine the dropstone origin and to reconstruct the Pleistocene ice driftways and surface currents. The IRD composition alternates repeatedly between carbonate- and quartz-dominated assemblages, along with metamorphic and igneous rocks, clastic rocks, and some chert. The highest quartz content is found on the Alpha Ridge, while carbonate percentages are highest on the Northwind Ridge (NWR) and the Chukchi Cap. The source for the carbonates is the area around Banks and Victoria Islands and parts of northern Canada. Quartz most likely originated from the central Queen Elizabeth Islands. IRD on the southeastern Alpha Ridge is dominated by mafic crystalline rocks from northern Ellesmere Island and northern Greenland. At least six major glacial intervals are identified within the last 1 million years, during which icebergs drifted toward the west in the Beaufort Sea, straight northward in the central Arctic Ocean, and northeastward on the SE Alpha Ridge.

  19. DETERMINATION AND DOSE CONTRIBUTION OF URANIUM ISOTOPES AND 210Po ACTIVITY CONCENTRATIONS OF NATURAL SPRING WATERS IN THE PROVINCE OF GRANADA, SPAIN.

    PubMed

    Milena-Pérez, A; Piñero-García, F; Expósito-Suárez, V M; Mantero, J; Benavente, J; Ferro-García, M A

    2018-03-01

    The activity concentrations of alpha-emitters comprising isotopes of uranium (238, 234, 235U) and polonium (210Po) were measured using alpha-particle spectrometry in natural spring waters in the province of Granada, Spain. These water are consumed by the population of the zone who live in villages. This is almost half of the population of the whole region. Mean values of activity concentrations found are 42.61 ± 2.66; 49.55 ± 3.03; 1.64 ± 0.28 and 1.74 ± 0.15 mBq L-1 for 238U, 234U, 235U and 210Po, respectively. Finally, the radiological impact of the analysed waters has been determined, in terms of the estimation of the committed annual effective dose due to the ingestion of the water. The assessment has been carried out for five age groups with the aim to cover all the population. The calculated annual effective doses are observed to be below the prescribed dose limit of 100 μSv y-1 recommended by WHO.

  20. Reappraisal of solid selective emitters

    NASA Technical Reports Server (NTRS)

    Chubb, Donald L.

    1990-01-01

    New rare earth oxide emitters show greater efficiency than previous emitters. As a result, based on a simple model the efficiency of these emitters was calculated. Results indicate that the emission band of the selective emitter must be at relatively low energy (less than or equal to .52 eV) to obtain maximum efficiency at moderate emitter temperatures (less than or equal to 1500 K). Thus low bandgap energy PV materials are required to obtain an efficient thermophotovoltaic (TPV) system. Of the 4 specific rare earths (Nd, Ho, Er, Yb) studied Ho has the largest efficiency at moderate temperatures (72 percent at 1500 K). A comparison was made between a selective emitter TPV system and a TPV system that uses a thermal emitter plus a band pass filter to make the thermal emitter behave like a selective emitter. Results of the comparison indicate that only for very optimistic filter and thermal emitter properties will the filter TPV system have a greater efficiency than the selective emitter system.

  1. Tuning Into Brown Dwarfs: Long-Term Radio Monitoring of Two Very Low Mass Dwarfs

    NASA Astrophysics Data System (ADS)

    Van Linge, Russell; Burgasser, Adam J.; Melis, Carl; Williams, Peter K. G.

    2017-01-01

    The very lowest-mass (VLM) stars and brown dwarfs, with effective temperatures T < 3000 K, exhibit mixed magnetic activity trends, with H-alpha and X-ray emission that declines rapidly beyond type M7/M8, but persistent radio emission in roughly 10-20% of sources. The dozen or so VLM radio emitters known show a broad range of emission characteristics and time-dependent behavior, including steady persistent emission, periodic oscillations, periodic polarized bursts, and aperiodic flares. Understanding the evolution of these variability patterns, and in particular whether they undergo solar-like cycles, requires long-term monitoring. We report the results of a long-term JVLA monitoring program of two magnetically-active VLM dwarf binaries, the young M7 2MASS 1314+1320AB and older L5 2MASS 1315-2649AB. On the bi-weekly cadence, 2MASS 1314 continues to show variability by revealing regular flaring while 2MASS 1315 continues to be a quiescent emitter. On the daily time scale, both sources show a mean flux density that can vary significantly just over a few days. These results suggest long-term radio behavior in radio-emitting VLM dwarfs is just as diverse and complex as short-term behavior.

  2. Regulation of nicotinic acetylcholine receptor phosphorylation in rat myotubes by forskolin and cAMP

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miles, K.; Anthony, D.T.; Rubin, L.L.

    1987-09-01

    The nicotinic acetylcholine receptor (Ac-ChoR) from rat myotubes prelabeled in culture with (/sup 32/P)orthophosphate was isolated by acetylcholine affinity chromatography followed by immunoaffinity chromatography. Under basal conditions, the nicotinic AcChoR was shown to be phosphorylated in situ on the ..beta.. and delta subunits. Regulation of AcChoR phosphorylation by cAMP-dependent protein kinase was explored by the addition of forskolin or cAMP analogues to prelabeled cell cultures. Forskolin, an activator of adenylate cyclase, stimulated the phosphorylation of the delta subunit 20-fold over basal phosphorylation and induced phosphorylation of the ..cap alpha.. subunit. The effect of forskolin was dose dependent with a half-maximalmore » response at 8 ..mu..M in the presence of 35 ..mu..M Ro 20-1724, a phosphodiesterase inhibitor. Stimulation of delta subunit phosphorylation was almost maximal within 5 min, whereas stimulation of ..cap alpha.. subunit phosphorylation was not maximal until 45 min after forskolin treatment. Stimulation of AcChoR phosphorylation by 8-benzylthioadenosine 3',5'-cyclic monophosphate was identical to that obtained by forskolin. Two-dimensional thermolytic phosphopeptide maps of the delta subunit revealed a single major phosphopeptide. These results correlate closely with the observed effects of forskolin on AcChoR desensitization in muscle and suggest that cAMP-dependent phosphorylation of the delta subunit increases the rate of AcChoR desensitization in rat myotubes.« less

  3. Rare Earth Garnet Selective Emitter

    NASA Technical Reports Server (NTRS)

    Lowe, Roland A.; Chubb, Donald L.; Farmer, Serene C.; Good, Brian S.

    1994-01-01

    Thin film Ho-YAG and Er-YAG emitters with a platinum substrate exhibit high spectral emittance in the emission band (epsilon(sub lambda) approx. = 0.75, sup 4)|(sub 15/2) - (sup 4)|(sub 13/2),for Er-YAG and epsilon(sub lambda) approx. = 0.65, (sup 5)|(sub 7) - (sup 5)|(sub 8) for Ho-YAG) at 1500 K. In addition, low out-of-band spectral emittance, epsilon(sub lambda) less than 0.2, suggest these materials would be excellent candidates for high efficiency selective emitters in thermophotovoltaic (TPV) systems operating at moderate temperatures (1200-1500 K). Spectral emittance measurements of the thin films were made (1.2 less than lambda less than 3.0 microns) and compared to the theoretical emittances calculated using measured values of the spectral extinction coefficient. In this paper we present the results for a new class of rare earth ion selective emitters. These emitters are thin sections (less than 1 mm) of yttrium aluminum garnet (YAG) single crystal with a rare earth substitutional impurity. Selective emitters in the near IR are of special interest for thermophotovoltaic (TPV) energy conversion. The most promising solid selective emitters for use in a TPV system are rare earth oxides. Early spectral emittance work on rare earth oxides showed strong emission bands in the infrared (0.9 - 3 microns). However, the emittance outside the emission band was also significant and the efficiency of these emitters was low. Recent improvements in efficiency have been made with emitters fabricated from fine (5 - 10 microns) rare earth oxide fibers similar to the Welsbach mantle used in gas lanterns. However, the rare earth garnet emitters are more rugged than the mantle type emitters. A thin film selective emitter on a low emissivity substrate such as gold, platinum etc., is rugged and easily adapted to a wide variety of thermal sources. The garnet structure and its many subgroups have been successfully used as hosts for rare earth ions, introduced as substitutional impurities, in the development of solid state laser crystals. Doping, dependent on the particular ion and crystal structure, may be as high as 100 at. % (complete substitution of yttrium ion with the rare earth ion). These materials have high melting points, 1940 C for YAG (Yttrium Aluminum Garnet), and low emissivity in the near infrared making them excellent candidates for a thin film selective emitter. As previously stated, the spectral emittance of a rare earth emitter is characterized by one or more well defined emission bands. Outside the emission band the emittance(absorptance) is much lower. Therefore, it is expected that emission outside the band for a thin film selective emitter will be dominated by the emitter substrate. For an efficient emitter (power in the emission band/total emitted power) the substrate must have low emittance, epsilon(sub S). This paper presents normal spectral emittance, epsilon(sub lambda), measurements of holmium(Ho) and erbium (Er) doped YAG thin film selective emitters at (1500 K), and compares those results with the theoretical spectral emittance.

  4. Dosimetry of radium-223 and progeny

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fisher, D.R.; Sgouros, G.

    Radium-223 is a short-lived (11.4 d) alpha emitter with potential applications in radioimmunotherapy of cancer. Radium-223 can be complexed and linked to protein delivery molecules for specific tumor-cell targeting. It decays through a cascade of short-lived alpha- and beta-emitting daughters with emission of about 28 MeV of energy through complete decay. The first three alpha particles are essentially instantaneous. Photons associated with Ra-223 and progeny provide the means for tumor and normal-organ imaging and dosimetry. Two beta particles provide additional therapeutic value. Radium-223 may be produced economically and in sufficient amounts for widescale application. Many aspects of the chemistry ofmore » carrier-free isotope preparation, complexation, and linkage to the antibody have been developed and are being tested. The radiation dosimetry of a Ra-223-labeled antibody shows favorable tumor to normal tissue dose ratios for therapy. The 11.4-d half-life of Ra-223 allows sufficient time for immunoconjugate preparation, administration, and tumor localization by carrier antibodies before significant radiological decay takes place. If 0.01 percent of a 37 MBq (1 mCi) injection deposits in a one gram tumor mass, and if the activity is retained with a typical effective half-time (75 h), the absorbed dose will be 163 mGy MBq{sup {minus}1} (600 rad mCi{sup {minus}1}) administered. 49 refs., 5 figs., 2 tabs.« less

  5. Shielding in ungated field emitter arrays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harris, J. R.; Jensen, K. L.; Shiffler, D. A.

    Cathodes consisting of arrays of high aspect ratio field emitters are of great interest as sources of electron beams for vacuum electronic devices. The desire for high currents and current densities drives the cathode designer towards a denser array, but for ungated emitters, denser arrays also lead to increased shielding, in which the field enhancement factor β of each emitter is reduced due to the presence of the other emitters in the array. To facilitate the study of these arrays, we have developed a method for modeling high aspect ratio emitters using tapered dipole line charges. This method can bemore » used to investigate proximity effects from similar emitters an arbitrary distance away and is much less computationally demanding than competing simulation approaches. Here, we introduce this method and use it to study shielding as a function of array geometry. Emitters with aspect ratios of 10{sup 2}–10{sup 4} are modeled, and the shielding-induced reduction in β is considered as a function of tip-to-tip spacing for emitter pairs and for large arrays with triangular and square unit cells. Shielding is found to be negligible when the emitter spacing is greater than the emitter height for the two-emitter array, or about 2.5 times the emitter height in the large arrays, in agreement with previously published results. Because the onset of shielding occurs at virtually the same emitter spacing in the square and triangular arrays, the triangular array is preferred for its higher emitter density at a given emitter spacing. The primary contribution to shielding in large arrays is found to come from emitters within a distance of three times the unit cell spacing for both square and triangular arrays.« less

  6. Chemical regeneration of emitter surface increases thermionic diode life

    NASA Technical Reports Server (NTRS)

    Breiteieser, R.

    1966-01-01

    Chemical regeneration of sublimated emitter electrode increases the operating efficiency and life of thermionic diodes. A gas which forms chemical compounds with the sublimated emitter material is introduced into the space between the emitter and the collector. The compounds migrate to the emitter where they decompose and redeposit the emitter material.

  7. Use of probabilistic neural networks for emitter correlation

    NASA Astrophysics Data System (ADS)

    Maloney, P. S.

    1990-08-01

    The Probabilistic Neural Network (PNN) as described by Specht''3 has been successfully applied to a number of emitter correlation problems involving operational data for training and testing of the neural net work. The PNN has been found to be a reliable classification tool for determining emitter type or even identifying specific emitter platforms given appropriate representative data sets for training con sisting only of parametric data from electronic intelligence (ELINT) reports. Four separate feasibility studies have been conducted to prove the usefulness of PNN in this application area: . Hull-to-emitter correlation (HULTEC) for identification of seagoing emitter platforms . Identification of landbased emitters from airborne sensors . Pulse sorting according to emitter of origin . Emitter typing based on a dynamically learning neural network. 1 .

  8. [Efficiencies of contamination source for flooring and some materials used in unencapsulated radioactivity handling facilities].

    PubMed

    Yoshida, M; Yoshizawa, M; Minami, K

    1990-09-01

    The efficiencies of contamination source, defined in ISO Report 7506-1, were experimentally determined for such materials as flooring, polyethylene, smear-tested filter paper and stainless steel plate. 5 nuclides of 147Pm, 60Co, 137Cs, 204Tl and 90Sr-Y were used to study beta-ray energy dependence of the efficiency, and 241Am as alpha-ray emitter. The charge-up effect in the measurement by a window-less 2 pi-proportional counter was evaluated to obtain reliable surface emission rate. The measured efficiencies for non-permeable materials, except for two cases, are more than 0.5 even for 147Pm. The ISO recommendations were shown to be conservative enough on the basis of present results.

  9. Thorium-232 fission induced by light charged particles up to 70 MeV

    NASA Astrophysics Data System (ADS)

    Métivier, Vincent; Duchemin, Charlotte; Guertin, Arnaud; Michel, Nathalie; Haddad, Férid

    2017-09-01

    Studies have been devoted to the production of alpha emitters for medical application in collaboration with the GIP ARRONAX that possesses a high energy and high intensity multi-particle cyclotron. The productions of Ra-223, Ac-225 and U-230 have been investigated from the Th-232(p,x) and Th-232(d,x) reactions using the stacked-foils method and gamma spectrometry measurements. These reactions have led to the production of several fission products, including some with a medical interest like Mo-99, Cd-115g and I-131. This article presents cross section data of fission products obtained from these undedicated experiments. These data have been also compared with the TALYS code results.

  10. Occurrence of rhombic prisms in some structures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nyman, H.

    1976-02-01

    An ideal rhombic prism is defined as two regular trigonal prisms sharing a square face. In terms of such rhombic prisms, the structures of CrB and ..cap alpha..-PdCl/sub 2/, U/sub 3/Si/sub 2/ and Au/sub 3/Zn, and CoCa/sub 3/ and PdS are easily described. A network of rhombic prisms, with cubic symmetry, is also used to describe the structures of CoAs/sub 3/, Sc(OH)/sub 3/, WAl/sub 12/, and NaMn/sub 7/O/sub 12/.

  11. In vitro histamine H/sub 2/-antagonist activity of the novel compound HUK 978

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coombes, J.D.; Norris, D.B.; Rising, T.J.

    1985-11-04

    Histamine stimulated adenylate cyclase from guinea-pig fundic mucosa and /sup 3/H-tiotidine binding in guinea-pig cerebral cortex were used to assess the in-vitro histamine H/sub 2/-activity of the novel H/sub 2/-antagonist HUK 978. The results showed that HUK 978 was a more potent H/sub 2/-antagonist than either cimetidine or ranitidine. HUK 978 was also shown to be devoid of activity at the histamine H-/sub 1/-receptor, the muscarinic receptor and the ..cap alpha.. and ..beta..-adrenergic receptors.

  12. High temperature bias line stabilized current sources

    DOEpatents

    Patterson, III, Raymond B.

    1984-01-01

    A compensation device for the base of emitter follower configured bipolar transistors becoming operable at elevated temperatures including a bipolar transistor of a geometry of not more than half the geometry of the bipolar emitter follower having its collector connected to the base of the emitter follower and its base and emitter connected together and to the emitter of the emitter follower.

  13. High temperature bias line stabilized current sources

    DOEpatents

    Patterson, R.B. III.

    1984-09-11

    A compensation device for the base of emitter follower configured bipolar transistors becoming operable at elevated temperatures including a bipolar transistor of a geometry of not more than half the geometry of the bipolar emitter follower having its collector connected to the base of the emitter follower and its base and emitter connected together and to the emitter of the emitter follower. 1 fig.

  14. [Cytochemical localization and properties of selected nucleolytic enzymes].

    PubMed

    Sierakowska, Halina

    2015-01-01

    In the article there are shortly outlined studies on cytochemical localization of selected nucleolytic enzymes carried out between 1957-1986 by David Shugar and his coworkers. The histochemical localization of several nucleolytic enzymes in animal and plant tissues was determined by synthesis of specific substrates, alpha-naphthyl esters of 5'- and 3'-nucleotides and their derivatives. In rat tissues phosphodiesterase I was localized in the plasma membrane whereas phosphodiesterase II in the lizosomes, reflecting their physiological roles. The localization of pancreatic type ribonuclease in animal tissues was determined, indicating its role in extracellular digestion. Plant nucleotide pyrophosphatase was localized in several tissues, purified to near homogeneity from potato tubers and its properties and substrate specificity were determined. Application of this enzyme for removal of m7GMP from the "cap" of eukaryotic mRNA allowed to elucidate the role of "cap" in mRNA binding to ribosomes in the process of translation. Furthermore, cyclic nucleotide phosphodiesterase was isolated from potato tubers and its physicochemical properties, oligomeric structure and substrate specificity were elucidated.

  15. Optimized Design and Synthesis of Cell Permeable Biarsenical Cyanine Probe for Imaging Tagged Cytosolic Bacterial Proteins

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fu, Na; Xiong, Yijia; Squier, Thomas C.

    2013-01-21

    To optimize cellular delivery and specific labeling of tagged cytosolic proteins by biarsenical fluorescent probes build around a cyanine dye scaffold, we have systematically varied the polarity of the hydrophobic tails (i.e., 4-5 methylene groups appended by a sulfonate or methoxy ester moiety) and arsenic capping reagent (ethanedithiol versus benzenedithiol). Targeted labeling of the cytosolic proteins SlyD and the alpha subunit of RNA polymerase engineered with a tetracysteine tagging sequences demonstrate the utility of the newly synthesized probes for live-cell visualization, albeit with varying efficiencies and background intensities. Optimal routine labeling and visualization is apparent using the ethanedithiol capping reagentmore » with the uncharged methoxy ester functionalized acyl chains. These measurements demonstrate the general utility of this class of photostable and highly fluorescent biarsenical reagents based on the cyanine scaffold for in vivo targeting of tagged cellular proteins for live cell measurements of protein dynamics.« less

  16. Proteomic Profile of Unstable Atheroma Plaque: Increased Neutrophil Defensin 1, Clusterin, and Apolipoprotein E Levels in Carotid Secretome.

    PubMed

    Aragonès, Gemma; Auguet, Teresa; Guiu-Jurado, Esther; Berlanga, Alba; Curriu, Marta; Martinez, Salomé; Alibalic, Ajla; Aguilar, Carmen; Hernández, Esteban; Camara, María-Luisa; Canela, Núria; Herrero, Pol; Ruyra, Xavier; Martín-Paredero, Vicente; Richart, Cristóbal

    2016-03-04

    Because of the clinical significance of carotid atherosclerosis, the search for novel biomarkers has become a priority. The aim of the present study was to compare the protein secretion profile of the carotid atherosclerotic plaque (CAP, n = 12) and nonatherosclerotic mammary artery (MA, n = 10) secretomes. We used a nontargeted proteomic approach that incorporated tandem immunoaffinity depletion, iTRAQ labeling, and nanoflow liquid chromatography coupled to high-resolution mass spectrometry. In total, 162 proteins were quantified, of which 25 showed statistically significant differences in secretome levels between carotid atherosclerotic plaque and nondiseased mammary artery. We found increased levels of neutrophil defensin 1, apolipoprotein E, clusterin, and zinc-alpha-2-glycoprotein in CAP secretomes. Results were validated by ELISA assays. Also, differentially secreted proteins are involved in pathways such as focal adhesion and leukocyte transendothelial migration. In conclusion, this study provides a subset of identified proteins that are differently expressed in secretomes of clinical significance.

  17. Emitter location errors in electronic recognition system

    NASA Astrophysics Data System (ADS)

    Matuszewski, Jan; Dikta, Anna

    2017-04-01

    The paper describes some of the problems associated with emitter location calculations. This aspect is the most important part of the series of tasks in the electronic recognition systems. The basic tasks include: detection of emission of electromagnetic signals, tracking (determining the direction of emitter sources), signal analysis in order to classify different emitter types and the identification of the sources of emission of the same type. The paper presents a brief description of the main methods of emitter localization and the basic mathematical formulae for calculating their location. The errors' estimation has been made to determine the emitter location for three different methods and different scenarios of emitters and direction finding (DF) sensors deployment in the electromagnetic environment. The emitter has been established using a special computer program. On the basis of extensive numerical calculations, the evaluation of precise emitter location in the recognition systems for different configuration alignment of bearing devices and emitter was conducted. The calculations which have been made based on the simulated data for different methods of location are presented in the figures and respective tables. The obtained results demonstrate that calculation of the precise emitter location depends on: the number of DF sensors, the distances between emitter and DF sensors, their mutual location in the reconnaissance area and bearing errors. The precise emitter location varies depending on the number of obtained bearings. The higher the number of bearings, the better the accuracy of calculated emitter location in spite of relatively high bearing errors for each DF sensor.

  18. NO x emissions from large point sources: variability in ozone production, resulting health damages and economic costs

    NASA Astrophysics Data System (ADS)

    Mauzerall, Denise L.; Sultan, Babar; Kim, Namsoug; Bradford, David F.

    We present a proof-of-concept analysis of the measurement of the health damage of ozone (O 3) produced from nitrogen oxides (NO=NO+NO) emitted by individual large point sources in the eastern United States. We use a regional atmospheric model of the eastern United States, the Comprehensive Air quality Model with Extensions (CAMx), to quantify the variable impact that a fixed quantity of NO x emitted from individual sources can have on the downwind concentration of surface O 3, depending on temperature and local biogenic hydrocarbon emissions. We also examine the dependence of resulting O 3-related health damages on the size of the exposed population. The investigation is relevant to the increasingly widely used "cap and trade" approach to NO x regulation, which presumes that shifts of emissions over time and space, holding the total fixed over the course of the summer O 3 season, will have minimal effect on the environmental outcome. By contrast, we show that a shift of a unit of NO x emissions from one place or time to another could result in large changes in resulting health effects due to O 3 formation and exposure. We indicate how the type of modeling carried out here might be used to attach externality-correcting prices to emissions. Charging emitters fees that are commensurate with the damage caused by their NO x emissions would create an incentive for emitters to reduce emissions at times and in locations where they cause the largest damage.

  19. Soiling of building envelope surfaces and its effect on solar reflectance – Part III: Interlaboratory study of an accelerated aging method for roofing materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sleiman, Mohamad; Chen, Sharon; Gilbert, Haley E.

    A laboratory method to simulate natural exposure of roofing materials has been reported in a companion article. Here in the current article, we describe the results of an international, nine-participant interlaboratory study (ILS) conducted in accordance with ASTM Standard E691-09 to establish the precision and reproducibility of this protocol. The accelerated soiling and weathering method was applied four times by each laboratory to replicate coupons of 12 products representing a wide variety of roofing categories (single-ply membrane, factory-applied coating (on metal), bare metal, field-applied coating, asphalt shingle, modified-bitumen cap sheet, clay tile, and concrete tile). Participants reported initial and laboratory-agedmore » values of solar reflectance and thermal emittance. Measured solar reflectances were consistent within and across eight of the nine participating laboratories. Measured thermal emittances reported by six participants exhibited comparable consistency. For solar reflectance, the accelerated aging method is both repeatable and reproducible within an acceptable range of standard deviations: the repeatability standard deviation sr ranged from 0.008 to 0.015 (relative standard deviation of 1.2–2.1%) and the reproducibility standard deviation sR ranged from 0.022 to 0.036 (relative standard deviation of 3.2–5.8%). The ILS confirmed that the accelerated aging method can be reproduced by multiple independent laboratories with acceptable precision. In conclusion, this study supports the adoption of the accelerated aging practice to speed the evaluation and performance rating of new cool roofing materials.« less

  20. Improving the Sensitivity of Mass Spectrometry by Using a New Sheath Flow Electrospray Emitter Array at Subambient Pressures

    DOE PAGES

    Cox, Jonathan T.; Marginean, Ioan; Kelly, Ryan T.; ...

    2014-03-28

    Arrays of chemically etched emitters with individualized sheath gas capillaries have been developed to enhance electrospray ionization (ESI) at subambient pressures. By including an emitter array in a subambient pressure ionization with nanoelectrospray (SPIN) source, ionization and transmission efficiency can be maximized allowing for increased sensitivity in mass spectrometric analyses. The SPIN source eliminates the major ion losses at conventional ESI-mass spectrometry (MS) interface by placing the emitter in the first vacuum region of the instrument. To facilitate stable electrospray currents in such conditions we have developed an improved emitter array with individualized sheath gas around each emitter. The utilitymore » of the new emitter arrays for generating stable multi-electrosprays at subambient pressures was probed by coupling the emitter array/SPIN source with a time of flight (TOF) mass spectrometer. The instrument sensitivity was compared between single emitter/SPIN-MS and multi-emitter/SPIN-MS configurations using an equimolar solution of 9 peptides. An increase in sensitivity correlative to the number of emitters in the array was observed.« less

  1. Rare earth garnet selective emitter

    NASA Technical Reports Server (NTRS)

    Lowe, Roland A.; Chubb, Donald L.; Farmer, Serene C.; Good, Brian S.

    1994-01-01

    Thin film Ho-YAG and Er-YAG emitters with a platinum substrate exhibit high spectral emittance in the emission band (epsilon(sub lambda) approximately equal to 0.74, ((4)l(sub 15/2)) - ( (4)l(sub13/2)), for Er-YAG and epsilon(sub lambda) approximately equal to 0.65, ((5)l(sub 7))-((5)l(sub 8)) for Ho-YAG) at excellent candidates for high efficiency selective emitters in the thermophotovoltaics (TPV) systems operating at moderate temperatures (1200-1500K). Spectral emittance measurements of the thin films were made (1.2 less than lambda less than 3.0 microns) and compared to the theoretical emittances calculated using measured values of the spectral extinction coefficient. In this paper we present the results for a new class of rare earth ion selective emitters. These emitters are thin sections (less than 1 mm) of yttrium aluminum garnet (YAG) single crystal with a rare earth substitutional impurity. This paper presents normal spectral emittance, epsilon(sub lambda), measurements of holmium (Ho), and erbium (Er) doped YAG thin film selective emitters at 1500 K, and compares those results with the theoretical spectral emittance.

  2. Improving the Sensitivity of Mass Spectrometry by Using a New Sheath Flow Electrospray Emitter Array at Subambient Pressures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cox, Jonathan T.; Marginean, Ioan; Kelly, Ryan T.

    Arrays of chemically etched emitters with individualized sheath gas capillaries have been developed to enhance electrospray ionization (ESI) at subambient pressures. By including an emitter array in a subambient pressure ionization with nanoelectrospray (SPIN) source, ionization and transmission efficiency can be maximized allowing for increased sensitivity in mass spectrometric analyses. The SPIN source eliminates the major ion losses at conventional ESI-mass spectrometry (MS) interface by placing the emitter in the first vacuum region of the instrument. To facilitate stable electrospray currents in such conditions we have developed an improved emitter array with individualized sheath gas around each emitter. The utilitymore » of the new emitter arrays for generating stable multi-electrosprays at subambient pressures was probed by coupling the emitter array/SPIN source with a time of flight (TOF) mass spectrometer. The instrument sensitivity was compared between single emitter/SPIN-MS and multi-emitter/SPIN-MS configurations using an equimolar solution of 9 peptides. An increase in sensitivity correlative to the number of emitters in the array was observed.« less

  3. Determination of the efficiency of commercially available dose calibrators for beta-emitters.

    PubMed

    Valley, Jean-François; Bulling, Shelley; Leresche, Michel; Wastiel, Claude

    2003-03-01

    The goals of this investigation are to determine whether commercially available dose calibrators can be used to measure the activity of beta-emitting radionuclides used in pain palliation and to establish whether manufacturer-supplied calibration factors are appropriate for this purpose. Six types of commercially available dose calibrators were studied. Dose calibrator response was controlled for 5 gamma-emitters used for calibration or typically encountered in routine use. For the 4 most commonly used beta-emitters ((32)P, (90)Sr, (90)Y, and (169)Er) dose calibrator efficiency was determined in the syringe geometry used for clinical applications. Efficiency of the calibrators was also measured for (153)Sm and (186)Re, 2 beta-emitters with significant gamma-contributions. Source activities were traceable to national standards. All calibrators measured gamma-emitters with a precision of +/-10%, in compliance with Swiss regulatory requirements. For beta-emitters, dose calibrator intrinsic efficiency depends strongly on the maximal energy of the beta-spectrum and is notably low for (169)Er. Manufacturer-supplied calibration factors give accurate results for beta-emitters with maximal beta-energy in the middle-energy range (1 MeV) but are not appropriate for use with low-energy ((169)Er) or high-energy ((90)Y) beta-emitters. beta-emitters with significant gamma-contributions behave like gamma-emitters. Commercially available dose calibrators have an intrinsic efficiency that is sufficient for the measurement of beta-emitters, including beta-emitters with a low maximum beta-energy. Manufacturer-supplied calibration factors are reliable for gamma-emitters and beta-emitters in the middle-energy range. For low- and high-energy beta-emitters, the use of manufacturer-supplied calibration factors introduces significant measurement inaccuracy.

  4. Multinozzle emitter arrays for ultrahigh-throughput nanoelectrospray mass spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Daojing; Mao, Pan; Wang, Hung-Ta

    The present invention provides for a structure comprising a plurality of emitters, wherein a first nozzle of a first emitter and a second nozzle of a second emitter emit in two directions that are not or essentially not in the same direction; wherein the walls of the nozzles and the emitters form a monolithic whole. The present invention also provides for a structure comprising an emitter with a sharpened end from which the emitter emits; wherein the emitters forms a monolithic whole. The present invention also provides for a fully integrated separation of proteins and small molecules on a siliconmore » chip before the electrospray mass spectrometry analysis.« less

  5. Parallel nanomanufacturing via electrohydrodynamic jetting from microfabricated externally-fed emitter arrays

    NASA Astrophysics Data System (ADS)

    Ponce de Leon, Philip J.; Hill, Frances A.; Heubel, Eric V.; Velásquez-García, Luis F.

    2015-06-01

    We report the design, fabrication, and characterization of planar arrays of externally-fed silicon electrospinning emitters for high-throughput generation of polymer nanofibers. Arrays with as many as 225 emitters and with emitter density as large as 100 emitters cm-2 were characterized using a solution of dissolved PEO in water and ethanol. Devices with emitter density as high as 25 emitters cm-2 deposit uniform imprints comprising fibers with diameters on the order of a few hundred nanometers. Mass flux rates as high as 417 g hr-1 m-2 were measured, i.e., four times the reported production rate of the leading commercial free-surface electrospinning sources. Throughput increases with increasing array size at constant emitter density, suggesting the design can be scaled up with no loss of productivity. Devices with emitter density equal to 100 emitters cm-2 fail to generate fibers but uniformly generate electrosprayed droplets. For the arrays tested, the largest measured mass flux resulted from arrays with larger emitter separation operating at larger bias voltages, indicating the strong influence of electrical field enhancement on the performance of the devices. Incorporation of a ground electrode surrounding the array tips helps equalize the emitter field enhancement across the array as well as control the spread of the imprints over larger distances.

  6. A combined emitter threat assessment method based on ICW-RCM

    NASA Astrophysics Data System (ADS)

    Zhang, Ying; Wang, Hongwei; Guo, Xiaotao; Wang, Yubing

    2017-08-01

    Considering that the tradition al emitter threat assessment methods are difficult to intuitively reflect the degree of target threaten and the deficiency of real-time and complexity, on the basis of radar chart method(RCM), an algorithm of emitter combined threat assessment based on ICW-RCM (improved combination weighting method, ICW) is proposed. The coarse sorting is integrated with fine sorting in emitter combined threat assessment, sequencing the emitter threat level roughly accordance to radar operation mode, and reducing task priority of the low-threat emitter; On the basis of ICW-RCM, sequencing the same radar operation mode emitter roughly, finally, obtain the results of emitter threat assessment through coarse and fine sorting. Simulation analyses show the correctness and effectiveness of this algorithm. Comparing with classical method of emitter threat assessment based on CW-RCM, the algorithm is visual in image and can work quickly with lower complexity.

  7. Apoptosis of vascular smooth muscle cells induces features of plaque vulnerability in atherosclerosis.

    PubMed

    Clarke, Murray C H; Figg, Nichola; Maguire, Janet J; Davenport, Anthony P; Goddard, Martin; Littlewood, Trevor D; Bennett, Martin R

    2006-09-01

    Vascular smooth muscle cell (VSMC) apoptosis occurs in many arterial diseases, including aneurysm formation, angioplasty restenosis and atherosclerosis. Although VSMC apoptosis promotes vessel remodeling, coagulation and inflammation, its precise contribution to these diseases is unknown, given that apoptosis frequently accompanies vessel injury or alterations to flow. To study the direct consequences of VSMC apoptosis, we generated transgenic mice expressing the human diphtheria toxin receptor (hDTR, encoded by HBEGF) from a minimal Tagln (also known as SM22alpha) promoter. Despite apoptosis inducing loss of 50-70% of VSMCs, normal arteries showed no inflammation, reactive proliferation, thrombosis, remodeling or aneurysm formation. In contrast, VSMC apoptosis in atherosclerotic plaques of SM22alpha-hDTR Apoe-/- mice induced marked thinning of fibrous cap, loss of collagen and matrix, accumulation of cell debris and intense intimal inflammation. We conclude that VSMC apoptosis is 'silent' in normal arteries, which have a large capacity to withstand cell loss. In contrast, VSMC apoptosis alone is sufficient to induce features of plaque vulnerability in atherosclerosis. SM22alpha-hDTR Apoe-/- mice may represent an important new model to test agents proposed to stabilize atherosclerotic plaques.

  8. A New Conjugation Method Used for the Development of an Immunoassay for the Detection of Amanitin, a Deadly Mushroom Toxin.

    PubMed

    Bever, Candace S; Barnych, Bogdan; Hnasko, Robert; Cheng, Luisa W; Stanker, Larry H

    2018-06-28

    One of the deadliest mushrooms is the death cap mushroom, Amanita phalloides . The most toxic constituent is α-amanitin, a bicyclic octapeptide, which damages the liver and kidneys. To develop a new tool for detecting this toxin, polyclonal antibodies were generated and characterized. Both α- and β-amanitin were coupled to carrier proteins through four different linking chemistries, one of which has never before been described. These conjugates were evaluated for their effectiveness in generating antibodies specific for the free toxin, as well as their utility in formatting heterogeneous assays with high sensitivity. Ultimately, these efforts yielded a newly described conjugation procedure utilizing periodate oxidation followed by reductive amination that successfully resulted in generating sensitive immunoassays (limit of detection (LOD), ~1.0 µg/L). The assays were characterized for their selectivity and were found to equally detect α-, β-, and γ-amanitin, and not cross-react with other toxins tested. Toxin detection in mushrooms was possible using a simple sample preparation method. This enzyme-linked immunosorbent assay (ELISA) is a simple and fast test, and readily detects amatoxins extracted from A. phalloides .

  9. Auto-Assembling Detoxified Staphylococcus aureus Alpha-Hemolysin Mimicking the Wild-Type Cytolytic Toxin.

    PubMed

    Fiaschi, Luigi; Di Palo, Benedetta; Scarselli, Maria; Pozzi, Clarissa; Tomaszewski, Kelly; Galletti, Bruno; Nardi-Dei, Vincenzo; Arcidiacono, Letizia; Mishra, Ravi P N; Mori, Elena; Pallaoro, Michele; Falugi, Fabiana; Torre, Antonina; Fontana, Maria Rita; Soriani, Marco; Bubeck Wardenburg, Juliane; Grandi, Guido; Rappuoli, Rino; Ferlenghi, Ilaria; Bagnoli, Fabio

    2016-06-01

    Staphylococcus aureus alpha-hemolysin (Hla) assembles into heptameric pores on the host cell membrane, causing lysis, apoptosis, and junction disruption. Herein, we present the design of a newly engineered S. aureus alpha-toxin, HlaPSGS, which lacks the predicted membrane-spanning stem domain. This protein is able to form heptamers in aqueous solution in the absence of lipophilic substrata, and its structure, obtained by transmission electron microscopy and single-particle reconstruction analysis, resembles the cap of the wild-type cytolytic Hla pore. HlaPSGS was found to be impaired in binding to host cells and to its receptor ADAM10 and to lack hemolytic and cytotoxic activity. Immunological studies using human sera as well as sera from mice convalescent from S. aureus infection suggested that the heptameric conformation of HlaPSGS mimics epitopes exposed by the cytolytic Hla pore during infection. Finally, immunization with this newly engineered Hla generated high protective immunity against staphylococcal infection in mice. Overall, this study provides unprecedented data on the natural immune response against Hla and suggests that the heptameric HlaPSGS is a highly valuable vaccine candidate against S. aureus. Copyright © 2016 Fiaschi et al.

  10. Auto-Assembling Detoxified Staphylococcus aureus Alpha-Hemolysin Mimicking the Wild-Type Cytolytic Toxin

    PubMed Central

    Fiaschi, Luigi; Di Palo, Benedetta; Scarselli, Maria; Pozzi, Clarissa; Tomaszewski, Kelly; Galletti, Bruno; Nardi-Dei, Vincenzo; Arcidiacono, Letizia; Mishra, Ravi P. N.; Mori, Elena; Pallaoro, Michele; Falugi, Fabiana; Torre, Antonina; Fontana, Maria Rita; Soriani, Marco; Bubeck Wardenburg, Juliane; Grandi, Guido; Rappuoli, Rino

    2016-01-01

    Staphylococcus aureus alpha-hemolysin (Hla) assembles into heptameric pores on the host cell membrane, causing lysis, apoptosis, and junction disruption. Herein, we present the design of a newly engineered S. aureus alpha-toxin, HlaPSGS, which lacks the predicted membrane-spanning stem domain. This protein is able to form heptamers in aqueous solution in the absence of lipophilic substrata, and its structure, obtained by transmission electron microscopy and single-particle reconstruction analysis, resembles the cap of the wild-type cytolytic Hla pore. HlaPSGS was found to be impaired in binding to host cells and to its receptor ADAM10 and to lack hemolytic and cytotoxic activity. Immunological studies using human sera as well as sera from mice convalescent from S. aureus infection suggested that the heptameric conformation of HlaPSGS mimics epitopes exposed by the cytolytic Hla pore during infection. Finally, immunization with this newly engineered Hla generated high protective immunity against staphylococcal infection in mice. Overall, this study provides unprecedented data on the natural immune response against Hla and suggests that the heptameric HlaPSGS is a highly valuable vaccine candidate against S. aureus. PMID:27030589

  11. Prolonged survival in secondary glioblastoma following local injection of targeted alpha therapy with 213Bi-substance P analogue.

    PubMed

    Krolicki, Leszek; Bruchertseifer, Frank; Kunikowska, Jolanta; Koziara, Henryk; Królicki, Bartosz; Jakuciński, Maciej; Pawlak, Dariusz; Apostolidis, Christos; Mirzadeh, Saed; Rola, Rafał; Merlo, Adrian; Morgenstern, Alfred

    2018-04-30

    Glioblastoma multiforme (GBM), the most common malignant brain tumor, mainly manifests as a primary de novo and less frequently as a secondary glial neoplasm. GBM has been demonstrated to overexpress the NK-1 receptor and substance P can be used as a ligand for targeted therapy. Alpha emitters, e.g. 213 Bi, that deposit their high energy within a short range allow the selective irradiation of tumor cells while sparing adjacent neuronal structures. Among 50 glioma patients of different subtypes that have to date been treated with targeted alpha therapy at the Medical University Warsaw, we report here the data on nine patients with secondary GBM. Following surgery, chemo- and radiotherapy, recurrent GBM was treated by intracavitary injection of 1-6 doses of 0.9-2.3 GBq 213 Bi- DOTA-[Thi 8 ,Met(O 2 ) 11 ]-substance P ( 213 Bi-DOTA-SP) in 2-month intervals. 68 Ga-DOTA-[Thi 8 ,Met(O 2 ) 11 ]-substance P ( 68 Ga-DOTA-SP) was co-injected with the therapeutic doses to assess biodistribution using PET/CT. Therapeutic response was monitored with MRI. Treatment with activities ranging from 1.4 to 9.7 (median 5.8) GBq 213 Bi- DOTA-SP was well tolerated with only mild transient adverse reactions, mainly headaches due to a transient perfocal edema reaction. The median progression free survival and overall survival time following the initiation of alpha therapy was 5.8 and 16.4 months, respectively. The median overall survival time from the first diagnosis was 52.3 months. Two out of nine patients are still alive 39 and 51 months, respectively, after the initiation of the therapy. Targeted alpha therapy of secondary GBM with 213 Bi-DOTA-SP is safe and well tolerated and may evolve as a promising novel therapeutic option for secondary GBM.

  12. Thermionic converter

    DOEpatents

    Rasor, Ned S.; Britt, Edward J.

    1976-01-01

    A gas-filled thermionic converter is provided with a collector and an emitter having a main emitter region and an auxiliary emitter region in electrical contact with the main emitter region. The main emitter region is so positioned with respect to the collector that a main gap is formed therebetween and the auxiliary emitter region is so positioned with respect to the collector that an auxiliary gap is formed therebetween partially separated from the main gap with access allowed between the gaps to allow ionizable gas in each gap to migrate therebetween. With heat applied to the emitter the work function of the auxiliary emitter region is sufficiently greater than the work function of the collector so that an ignited discharge occurs in the auxiliary gap and the work function of the main emitter region is so related to the work function of the collector that an unignited discharge occurs in the main gap sustained by the ions generated in the auxiliary gap. A current flows through a load coupled across the emitter and collector due to the unignited discharge in the main gap.

  13. Field emission characteristics of a small number of carbon fiber emitters

    NASA Astrophysics Data System (ADS)

    Tang, Wilkin W.; Shiffler, Donald A.; Harris, John R.; Jensen, Kevin L.; Golby, Ken; LaCour, Matthew; Knowles, Tim

    2016-09-01

    This paper reports an experiment that studies the emission characteristics of small number of field emitters. The experiment consists of nine carbon fibers in a square configuration. Experimental results show that the emission characteristics depend strongly on the separation between each emitter, providing evidence of the electric field screening effects. Our results indicate that as the separation between the emitters decreases, the emission current for a given voltage also decreases. The authors compare the experimental results to four carbon fiber emitters in a linear and square configurations as well as to two carbon fiber emitters in a paired array. Voltage-current traces show that the turn-on voltage is always larger for the nine carbon fiber emitters as compared to the two and four emitters in linear configurations, and approximately identical to the four emitters in a square configuration. The observations and analysis reported here, based on Fowler-Nordheim field emission theory, suggest the electric field screening effect depends critically on the number of emitters, the separation between them, and their overall geometric configuration.

  14. Electrochemical formation of field emitters

    DOEpatents

    Bernhardt, Anthony F.

    1999-01-01

    Electrochemical formation of field emitters, particularly useful in the fabrication of flat panel displays. The fabrication involves field emitting points in a gated field emitter structure. Metal field emitters are formed by electroplating and the shape of the formed emitter is controlled by the potential imposed on the gate as well as on a separate counter electrode. This allows sharp emitters to be formed in a more inexpensive and manufacturable process than vacuum deposition processes used at present. The fabrication process involves etching of the gate metal and the dielectric layer down to the resistor layer, and then electroplating the etched area and forming an electroplated emitter point in the etched area.

  15. Spectrally-engineered solar thermal photovoltaic devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lenert, Andrej; Bierman, David; Chan, Walker

    A solar thermal photovoltaic device, and method of forming same, includes a solar absorber and a spectrally selective emitter formed on either side of a thermally conductive substrate. The solar absorber is configured to absorb incident solar radiation. The solar absorber and the spectrally selective emitter are configured with an optimized emitter-to-absorber area ratio. The solar thermal photovoltaic device also includes a photovoltaic cell in thermal communication with the spectrally selective emitter. The spectrally selective emitter is configured to permit high emittance for energies above a bandgap of the photovoltaic cell and configured to permit low emittance for energies belowmore » the bandgap.« less

  16. Ultra-high Temperature Emittance Measurements for Space and Missile Applications

    NASA Technical Reports Server (NTRS)

    Rogers, Jan; Crandall, David

    2009-01-01

    Advanced modeling and design efforts for many aerospace components require high temperature emittance data. Applications requiring emittance data include propulsion systems, radiators, aeroshells, heatshields/thermal protection systems, and leading edge surfaces. The objective of this work is to provide emittance data at ultra-high temperatures. MSFC has a new instrument for the measurement of emittance at ultra-high temperatures, the Ultra-High Temperature Emissometer System (Ultra-HITEMS). AZ Technology Inc. developed the instrument, designed to provide emittance measurements over the temperature range 700-3500K. The Ultra-HITEMS instrument measures the emittance of samples, heated by lasers, in vacuum, using a blackbody source and a Fourier Transform Spectrometer. Detectors in a Nicolet 6700 FT-IR spectrometer measure emittance over the spectral range of 0.4-25 microns. Emitted energy from the specimen and output from a Mikron M390S blackbody source at the same temperature with matched collection geometry are measured. Integrating emittance over the spectral range yields the total emittance. The ratio provides a direct measure of total hemispherical emittance. Samples are heated using lasers. Optical pyrometry provides temperature data. Optical filters prevent interference from the heating lasers. Data for Inconel 718 show excellent agreement with results from literature and ASTM 835. Measurements taken from levitated spherical specimens provide total hemispherical emittance data; measurements taken from flat specimens mounted in the chamber provide near-normal emittance data. Data from selected characterization studies will be presented. The Ultra-HITEMS technique could advance space and missile technologies by advancing the knowledge base and the technology readiness level for ultra-high temperature materials.

  17. Emittance Theory for Thin Film Selective Emitter

    NASA Technical Reports Server (NTRS)

    Chubb, Donald L.; Lowe, Roland A.; Good, Brian S.

    1994-01-01

    Thin films of high temperature garnet materials such as yttrium aluminum garnet (YAG) doped with rare earths are currently being investigated as selective emitters. This paper presents a radiative transfer analysis of the thin film emitter. From this analysis the emitter efficiency and power density are calculated. Results based on measured extinction coefficients for erbium-YAG and holmium-YAG are presented. These results indicated that emitter efficiencies of 50 percent and power densities of several watts/sq cm are attainable at moderate temperatures (less than 1750 K).

  18. Evaluation of selected thermal control coatings for long-life space structures

    NASA Technical Reports Server (NTRS)

    Teichman, Louis A.; Slemp, Wayne S.; Witte, William G., Jr.

    1992-01-01

    Graphite-reinforced resin matrix composites are being considered for spacecraft structural applications because of their light weight, high stiffness, and lower thermal expansion. Thin protective coatings with stable optical properties and the proper ratio of solar absorption (alpha sub s) to thermal emittance (epsilon) minimize orbital thermal extremes and protect these materials against space environment degradation. Sputtered coatings applied directly to graphite/epoxy composite surfaces and anodized coatings applied to thin aluminum foil were studied for use both as an atomic oxygen barrier and as thermal control coatings. Additional effort was made to develop nickel-based coatings which could be applied directly to composites. These coating systems were selected because their inherent tenacity made them potentially more reliable than commercial white paints for long-life space missions. Results indicate that anodized aluminum foil coatings are suitable for tubular and flat composite structures on large platforms in low Earth orbit. Anodized foil provides protection against some elements of the natural space environment (atomic oxygen, ultraviolet, and particulate radiation) and offers a broad range of tailored alpha sub s/epsilon. The foil is readily available and can be produced in large quantities, while the anodizing process is a routine commercial technique.

  19. Rapid method to determine 226Ra in steel samples

    DOE PAGES

    Maxwell, Sherrod L.; Culligan, Brian; Hutchison, Jay B.; ...

    2017-09-22

    The rapid measurement of 226Ra in steel samples is very important in the event of a radiological emergency. 226Ra (T 1/2 = 1600 y) is a natural radionuclide present in the environment and a highly toxic alpha-emitter. Due to its long life and tendency to concentrate in bones, 226Ra ingestion or inhalation can lead to significant committed dose to individuals. A new method for the determination of 226Ra in steel samples has been developed at the Savannah River Environmental Laboratory. The new method employs a rugged acid digestion method that includes hydrofluoric acid, followed by a single precipitation step tomore » rapidly preconcentrate the radium and remove most of the dissolved steel sample matrix. Radium is then separated using a combination of cation exchange and extraction chromatography, and 226Ra is measured by alpha spectrometry. This approach has a sample preparation time of ~ 8 h for steel samples, has a very high tracer yield (> 88%), and removes interferences effectively. A 133Ba yield tracer is used so that samples can be counted immediately following the separation method, avoiding lengthy ingrowth times that are required in other methods.« less

  20. Approaches to Manufacturing Alpha Emitters For Radioimmunotherapeutic Drugs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gaylord King, A.; Givens, Kenneth R.; Miller, William H.

    Several alpha emitting isotopes have been proposed for radioimmunotherapy. To produce these nuclides reliably and in quantities needed, unique manufacturing approaches will be required. This paper describes the approaches that are being developed for the manufacture of 225Actinium (225 Ac) that decays to 213Bismuth (213 Bi) and the commercial manufacturing approaches. Oak Ridge National Laboratory (ORNL) currently supplies the actinium used for research and medical use. Today the ORNL 233U stockpiles only provide sufficient material for research quantities of 213 Bi. At the Institute for Transuranium Elements (ITU), in Karlsruhe, researchers have also developed a method of irradiating radium-226 withmore » protons in a cyclotron to produce actinium- 225 through the reaction 226Ra (p, 2n) 225Ac. Researchers from the Missouri University (MU), the Missouri University Research Reactor (MURR), MedActinium, Inc. and Los Alamos National Laboratory (LANL) are working on a collaborative effort to benchmark and optimize the production of 213Bi via neutron bombardment of 226Ra. MedActinium, Inc., in collaboration with commercial and institutional investigators at PG Research Foundation (PGRF) and Memorial Sloan Kettering Cancer Center (MSKCC), is developing commercial approaches to manufacturing these unique radioimmunotherapeutic drugs.« less

  1. Rapid method to determine 226Ra in steel samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxwell, Sherrod L.; Culligan, Brian; Hutchison, Jay B.

    The rapid measurement of 226Ra in steel samples is very important in the event of a radiological emergency. 226Ra (T 1/2 = 1600 y) is a natural radionuclide present in the environment and a highly toxic alpha-emitter. Due to its long life and tendency to concentrate in bones, 226Ra ingestion or inhalation can lead to significant committed dose to individuals. A new method for the determination of 226Ra in steel samples has been developed at the Savannah River Environmental Laboratory. The new method employs a rugged acid digestion method that includes hydrofluoric acid, followed by a single precipitation step tomore » rapidly preconcentrate the radium and remove most of the dissolved steel sample matrix. Radium is then separated using a combination of cation exchange and extraction chromatography, and 226Ra is measured by alpha spectrometry. This approach has a sample preparation time of ~ 8 h for steel samples, has a very high tracer yield (> 88%), and removes interferences effectively. A 133Ba yield tracer is used so that samples can be counted immediately following the separation method, avoiding lengthy ingrowth times that are required in other methods.« less

  2. Effect of radiation-induced amorphization on smectite dissolution.

    PubMed

    Fourdrin, C; Allard, T; Monnet, I; Menguy, N; Benedetti, M; Calas, G

    2010-04-01

    Effects of radiation-induced amorphization of smectite were investigated using artificial irradiation. Beams of 925 MeV Xenon ions with radiation dose reaching 73 MGy were used to simulate the effects generated by alpha recoil nuclei or fission products in the context of high level nuclear waste repository. Amorphization was controlled by X-ray diffraction, transmission electron microscopy, and Fourier transform infrared spectroscopy. An important coalescence of the smectite sheets was observed which lead to a loss of interparticle porosity. The amorphization is revealed by a loss of long-range structure and accompanied by dehydroxylation. The dissolution rate far-from-equilibrium shows that the amount of silica in solution is two times larger in the amorphous sample than in the reference clay, a value which may be enhanced by orders of magnitude when considering the relative surface area of the samples. Irradiation-induced amorphization thus facilitates dissolution of the clay-derived material. This has to be taken into account for the safety assessment of high level nuclear waste repository, particularly in a scenario of leakage of the waste package which would deliver alpha emitters able to amorphize smectite after a limited period of time.

  3. Effect of capping and particle size on Raman laser-induced degradation of {gamma}-Fe{sub 2}O{sub 3} nanoparticles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Varadwaj, K.S.K.; Panigrahi, M.K.; Ghose, J.

    2004-11-01

    Diol capped {gamma}-Fe{sub 2}O{sub 3} nanoparticles are prepared from ferric nitrate by refluxing in 1,4-butanediol (9.5nm) and 1,5-pentanediol (15nm) and uncapped particles are prepared by refluxing in 1,2-propanediol followed by sintering the alkoxide formed. X-ray diffraction (XRD) shows that all the samples have the spinel phase. Raman spectroscopy shows that the samples prepared in 1,4-butanediol and 1,5-pentanediol and 1,2-propanediol (sintered at 573 and 673K) are {gamma}-Fe{sub 2}O{sub 3} and the 773K-sintered sample is Fe{sub 3}O{sub 4}. Raman laser studies carried out at various laser powers show that all the samples undergo laser-induced degradation to {alpha}-Fe{sub 2}O{sub 3} at higher lasermore » power. The capped samples are however, found more stable to degradation than the uncapped samples. The stability of {gamma}-Fe{sub 2}O{sub 3} sample with large particle size (15.4nm) is more than the sample with small particle size (10.2nm). Fe{sub 3}O{sub 4} having a particle size of 48nm is however less stable than the smaller {gamma}-Fe{sub 2}O{sub 3} nanoparticles.« less

  4. Phase field models for heterogeneous nucleation: Application to inoculation in alpha-solidifying Ti-Al-B alloys

    NASA Astrophysics Data System (ADS)

    Apel, M.; Eiken, J.; Hecht, U.

    2014-02-01

    This paper aims at briefly reviewing phase field models applied to the simulation of heterogeneous nucleation and subsequent growth, with special emphasis on grain refinement by inoculation. The spherical cap and free growth model (e.g. A.L. Greer, et al., Acta Mater. 48, 2823 (2000)) has proven its applicability for different metallic systems, e.g. Al or Mg based alloys, by computing the grain refinement effect achieved by inoculation of the melt with inert seeding particles. However, recent experiments with peritectic Ti-Al-B alloys revealed that the grain refinement by TiB2 is less effective than predicted by the model. Phase field simulations can be applied to validate the approximations of the spherical cap and free growth model, e.g. by computing explicitly the latent heat release associated with different nucleation and growth scenarios. Here, simulation results for point-shaped nucleation, as well as for partially and completely wetted plate-like seed particles will be discussed with respect to recalescence and impact on grain refinement. It will be shown that particularly for large seeding particles (up to 30 μm), the free growth morphology clearly deviates from the assumed spherical cap and the initial growth - until the free growth barrier is reached - significantly contributes to the latent heat release and determines the recalescence temperature.

  5. Cholinergic anti-inflammatory pathway in the non-obese diabetic mouse model.

    PubMed

    Koopman, F A; Vosters, J L; Roescher, N; Broekstra, N; Tak, P P; Vervoordeldonk, M J

    2015-10-01

    Activation of the cholinergic anti-inflammatory pathway (CAP) has been shown to reduce inflammation in animal models, while abrogation of the pathway increases inflammation. We investigated whether modulation of CAP influences inflammation in the non-obese diabetic (NOD) mouse model for Sjögren's syndrome and type 1 diabetes. The alpha-7 nicotinic acetylcholine receptor (α7nAChR) was stimulated with AR-R17779 or nicotine in NOD mice. In a second study, unilateral cervical vagotomy was performed. α7nAChR expression, focus scores, and salivary flow were evaluated in salivary glands (SG) and insulitis score in the pancreas. Cytokines were measured in serum and SG. α7nAChR was expressed on myoepithelial cells in SG. Monocyte chemotactic protein-1 levels were reduced in SG after AR-R17779 treatment and tumor necrosis factor production was increased in the SG of the vagotomy group compared to controls. Focus score and salivary flow were unaffected. NOD mice developed diabetes more rapidly after vagotomy, but at completion of the study there were no statistically significant differences in number of mice that developed diabetes or in insulitis scores. Intervention of the CAP in NOD mice leads to minimal changes in inflammatory cytokines, but did not affect overall inflammation and function of SG or development of diabetes. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Recovering the systemic redshift of galaxies from their Lyman-alpha line profile

    NASA Astrophysics Data System (ADS)

    Verhamme, A.; Garel, T.; Ventou, E.; Contini, T.; Bouché, N.; Herenz, E. C.; Richard, J.; Bacon, R.; Schmidt, K. B.; Maseda, M.; Marino, R. A.; Brinchmann, J.; Cantalupo, S.; Caruana, J.; Clément, B.; Diener, C.; Drake, A. B.; Hashimoto, T.; Inami, H.; Kerutt, J.; Kollatschny, W.; Leclercq, F.; Patrício, V.; Schaye, J.; Wisotzki, L.; Zabl, J.

    2018-04-01

    The Lyman alpha (Lyα) line of Hydrogen is a prominent feature in the spectra of star-forming galaxies, usually redshifted by a few hundreds of km s-1 compared to the systemic redshift. This large offset hampers follow-up surveys, galaxy pair statistics and correlations with quasar absorption lines when only Lyα is available. We propose diagnostics that can be used to recover the systemic redshift directly from the properties of the Lyα line profile. We use spectroscopic observations of Lyman-Alpha Emitters (LAEs) for which a precise measurement of the systemic redshift is available. Our sample contains 13 sources detected between z ≈ 3 and z ≈ 6 as part of various Multi Unit Spectroscopic Explorer (MUSE) Guaranteed Time Observations (GTO). We also include a compilation of spectroscopic Lyα data from the literature spanning a wide redshift range (z ≈ 0 - 8). First, restricting our analysis to double-peaked Lyα spectra, we find a tight correlation between the velocity offset of the red peak with respect to the systemic redshift, V_peak^red, and the separation of the peaks. Secondly, we find a correlation between V_peak^red and the full width at half maximum of the Lyα line. Fitting formulas, to estimate systemic redshifts of galaxies with an accuracy of ≤100 km s-1 when only the Lyα emission line is available, are given for the two methods.

  7. Evidence of low injection efficiency for implanted p-emitters in bipolar 4H-SiC high-voltage diodes

    NASA Astrophysics Data System (ADS)

    Matthus, Christian D.; Huerner, Andreas; Erlbacher, Tobias; Bauer, Anton J.; Frey, Lothar

    2018-06-01

    In this study, the influence of the emitter efficiency on the forward current-voltage characteristics, especially the conductivity modulation of bipolar SiC-diodes was analyzed. It was determined that the emitter efficiency of p-emitters formed by ion implantation is significantly lower compared to p-emitters formed by epitaxy. In contrast to comparable studies, experimental approach was arranged that the influence of the quality of the drift-layer or the thickness of the emitter on the conductivity modulation could be excluded for the fabricated bipolar SiC-diodes of this work. Thus, it can be established that the lower emitter injection efficiency is mainly caused by the reduced electron lifetime in p-emitters formed by ion implantation. Therefore, a significant enhancement of the electron lifetime in implanted p-emitters is mandatory for e.g. SiC-MPS-diodes where the functionality of the devices depends significantly on the injection efficiency.

  8. Measurement of transverse emittance and coherence of double-gate field emitter array cathodes

    PubMed Central

    Tsujino, Soichiro; Das Kanungo, Prat; Monshipouri, Mahta; Lee, Chiwon; Miller, R.J. Dwayne

    2016-01-01

    Achieving small transverse beam emittance is important for high brightness cathodes for free electron lasers and electron diffraction and imaging experiments. Double-gate field emitter arrays with on-chip focussing electrode, operating with electrical switching or near infrared laser excitation, have been studied as cathodes that are competitive with photocathodes excited by ultraviolet lasers, but the experimental demonstration of the low emittance has been elusive. Here we demonstrate this for a field emitter array with an optimized double-gate structure by directly measuring the beam characteristics. Further we show the successful application of the double-gate field emitter array to observe the low-energy electron beam diffraction from suspended graphene in minimal setup. The observed low emittance and long coherence length are in good agreement with theory. These results demonstrate that our all-metal double-gate field emitters are highly promising for applications that demand extremely low-electron bunch-phase space volume and large transverse coherence. PMID:28008918

  9. Measurement of transverse emittance and coherence of double-gate field emitter array cathodes

    NASA Astrophysics Data System (ADS)

    Tsujino, Soichiro; Das Kanungo, Prat; Monshipouri, Mahta; Lee, Chiwon; Miller, R. J. Dwayne

    2016-12-01

    Achieving small transverse beam emittance is important for high brightness cathodes for free electron lasers and electron diffraction and imaging experiments. Double-gate field emitter arrays with on-chip focussing electrode, operating with electrical switching or near infrared laser excitation, have been studied as cathodes that are competitive with photocathodes excited by ultraviolet lasers, but the experimental demonstration of the low emittance has been elusive. Here we demonstrate this for a field emitter array with an optimized double-gate structure by directly measuring the beam characteristics. Further we show the successful application of the double-gate field emitter array to observe the low-energy electron beam diffraction from suspended graphene in minimal setup. The observed low emittance and long coherence length are in good agreement with theory. These results demonstrate that our all-metal double-gate field emitters are highly promising for applications that demand extremely low-electron bunch-phase space volume and large transverse coherence.

  10. Large area tunnel oxide passivated rear contact n -type Si solar cells with 21.2% efficiency: Large area tunnel oxide passivated rear contact n -type Si solar cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tao, Yuguo; Upadhyaya, Vijaykumar; Chen, Chia-Wei

    This paper reports on the implementation of carrier-selective tunnel oxide passivated rear contact for high-efficiency screen-printed large area n-type front junction crystalline Si solar cells. It is shown that the tunnel oxide grown in nitric acid at room temperature (25°C) and capped with n+ polysilicon layer provides excellent rear contact passivation with implied open-circuit voltage iVoc of 714mV and saturation current density J0b of 10.3 fA/cm2 for the back surface field region. The durability of this passivation scheme is also investigated for a back-end high temperature process. In combination with an ion-implanted Al2O3-passivated boron emitter and screen-printed front metal grids,more » this passivated rear contact enabled 21.2% efficient front junction Si solar cells on 239 cm2 commercial grade n-type Czochralski wafers.« less

  11. Searching for Lyman-alpha Emitters as a Probe of Cosmic Reionization and Peering Inside Galaxies in the First Two Billion Years

    NASA Astrophysics Data System (ADS)

    Jung, Intae; Finkelstein, Steven; CANDELS team

    2018-01-01

    In the reionization era an immediately accessible method for studying the intergalactic medium is to measure the equivalent width distribution of Lyman-alpha emission from galaxies with follow-up spectroscopy. To search for Lyman-alpha emission from galaxies at z ~ 5-8, we perform spectroscopic observations of candidate galaxies from the Cosmic Assembly Near-infrared Deep Extragalactic Legacy Survey (CANDELS). We utilize data from the Keck DEIMOS (optical) and MOSFIRE (near-infrared) spectrographs, ensuring a comprehensive wavelength coverage of Lyman-alpha emission at z ~ 5-8. We have a total of 1170 object-hours of spectroscopic integration of galaxies at z > 5: 118 galaxies with DEIMOS and 69 galaxies with MOSFIRE. The equivalent width distribution of Lyman-alpha emission is constrained with the number of detected objects from our dataset by constructing detailed simulations of mock emission lines, which consider observational conditions and the photometric redshift probability distribution function. We present our robust measure of the evolution of the Lyman-alpha emission equivalent width distribution at z ~ 5-8.Understanding what drives star-formation quenching in the early universe is a long-standing puzzle. To reveal the hidden relation of quenching with galaxy structural properties, particularly central stellar mass density, we perform the first spatially resolved stellar population study of galaxies at z ~ 4, utilizing the CANDELS imaging data set over the GOODS-S field. We examine 166 photometric-redshift-selected galaxies at 3.5 < z < 4.0 with additional deep K-band survey data from the HAWK-I UDS and GOODS Survey which covers the 4000Å break at these redshifts. We estimate the stellar mass, star formation rate, and dust extinction for galaxy inner and outer regions via spatially resolved spectral energy distribution fitting based on a Markov Chain Monte Carlo algorithm. By comparing specific star formation rates (sSFRs) between inner and outer parts of the galaxies we find that the majority of galaxies with high central mass densities show evidence for a preferentially lower sSFR in their centers than in their outer regions, indicative of reduced sSFRs in their central regions.

  12. Ballistocardiogram Artifact Removal with a Reference Layer and Standard EEG Cap

    PubMed Central

    Luo, Qingfei; Huang, Xiaoshan; Glover, Gary H.

    2014-01-01

    Background In simultaneous EEG-fMRI, the EEG recordings are severely contaminated by ballistocardiogram (BCG) artifacts, which are caused by cardiac pulsations. To reconstruct and remove the BCG artifacts, one promising method is to measure the artifacts in the absence of EEG signal by placing a group of electrodes (BCG electrodes) on a conductive layer (reference layer) insulated from the scalp. However, current BCG reference layer (BRL) methods either use a customized EEG cap composed of electrode pairs, or need to construct the custom reference layer through additional model-building experiments for each EEG-fMRI experiment. These requirements have limited the versatility and efficiency of BRL. The aim of this study is to propose a more practical and efficient BRL method and compare its performance with the most popular BCG removal method, the optimal basis sets (OBS) algorithm. New Method By designing the reference layer as a permanent and reusable cap, the new BRL method is able to be used with a standard EEG cap, and no extra experiments and preparations are needed to use the BRL in an EEG-fMRI experiment. Results The BRL method effectively removed the BCG artifacts from both oscillatory and evoked potential scalp recordings and recovered the EEG signal. Comparison with Existing Method Compared to the OBS, this new BRL method improved the contrast-to-noise ratios of the alpha-wave, visual, and auditory evoked potential signals by 101%, 76%, and 75% respectively, employing 160 BCG electrodes. Using only 20 BCG electrodes, the BRL improved the EEG signal by 74%/26%/41% respectively. Conclusion The proposed method can substantially improve the EEG signal quality compared with traditional methods. PMID:24960423

  13. Exposure to concentrated ambient PM2.5 alters the composition of gut microbiota in a murine model.

    PubMed

    Wang, Wanjun; Zhou, Ji; Chen, Minjie; Huang, Xingke; Xie, Xiaoyun; Li, Weihua; Cao, Qi; Kan, Haidong; Xu, Yanyi; Ying, Zhekang

    2018-04-17

    Exposure to ambient fine particulate matter (PM 2.5 ) correlates with abnormal glucose homeostasis, but the underlying biological mechanism has not been fully understood. The gut microbiota is an emerging crucial player in the homeostatic regulation of glucose metabolism. Few studies have investigated its role in the PM 2.5 exposure-induced abnormalities in glucose homeostasis. C57Bl/6J mice were exposed to filtered air (FA) or concentrated ambient PM 2.5 (CAP) for 12 months using a versatile aerosol concentration enrichment system (VACES) that was modified for long-term whole-body exposures. Their glucose homeostasis and gut microbiota were examined and analysed by correlation and mediation analysis. Intraperitoneal glucose tolerance test (IPGTT) and insulin tolerance test (ITT) showed that CAP exposure markedly impaired their glucose and insulin tolerance. Faecal microbiota analysis demonstrated that the impairment in glucose homeostasis was coincided with decreased faecal bacterial ACE and Chao-1 estimators (the indexes of community richness), while there was no significant change in all faecal fungal alpha diversity estimators. The Pearson's correlation analyses showed that the bacterial richness estimators were correlated with glucose and insulin tolerance, and the mediation analyses displayed a significant mediation of CAP exposure-induced glucose intolerance by the alteration in the bacterial Chao-1 estimator. LEfSe analyses revealed 24 bacterial and 21 fungal taxa differential between CAP- and FA-exposed animals. Of these, 14 and 20 bacterial taxa were correlated with IPGTT AUC and ITT AUC, respectively, and 5 fungal taxa were correlated with abnormalities in glucose metabolism. Chronic exposure to PM 2.5 causes gut dysbiosis and may subsequently contribute to the development of abnormalities in glucose metabolism.

  14. A model for optimizing delivery of targeted radionuclide therapies into resection cavity margins for the treatment of primary brain cancers.

    PubMed

    Raghavan, Raghu; Howell, Roger W; Zalutsky, Michael R

    2017-06-01

    Radionuclides conjugated to molecules that bind specifically to cancer cells are of great interest as a means to increase the specificity of radiotherapy. Currently, the methods to disseminate these targeted radiotherapeutics have been either systemic delivery or by bolus injection into the tumor or tumor resection cavity. Herein we model a potentially more efficient method of delivery, namely pressure-driven fluid flow, called convection-enhanced delivery (CED), where a device infuses the molecules in solution (or suspension) directly into the tissue of interest. In particular, we focus on the setting of primary brain cancer after debulking surgery, where the tissue margins surrounding the surgical resection cavity are infiltrated with tumor cells and the most frequent sites of tumor recurrence. We develop the combination of fluid flow, chemical kinetics, and radiation dose models needed to examine such protocols. We focus on Auger electron-emitting radionuclides (e.g. 67 Ga, 77 Br, 111 In, 125 I, 123 I, 193m Pt, 195m Pt) whose short range makes them ideal for targeted therapy in this setting of small foci of tumor spread within normal tissue. By solving these model equations, we confirm that a CED protocol is promising in allowing sufficient absorbed dose to destroy cancer cells with minimal absorbed dose to normal cells at clinically feasible activity levels. We also show that Auger emitters are ideal for this purpose while the longer range alpha particle emitters fail to meet criteria for effective therapy (as neither would energetic beta particle emitters). The model is used with simplified assumptions on the geometry and homogeneity of brain tissue to allow semi-analytic solutions to be displayed, and with the purpose of a first examination of this new delivery protocol proposed for radionuclide therapy. However, we emphasize that it is immediately extensible to personalized therapy treatment planning as we have previously shown for conventional CED, at the price of requiring a fully numerical computerized approach.

  15. Cleavage of the actin-capping protein alpha -adducin at Asp-Asp-Ser-Asp633-Ala by caspase-3 is preceded by its phosphorylation on serine 726 in cisplatin-induced apoptosis of renal epithelial cells.

    PubMed

    van de Water, B; Tijdens, I B; Verbrugge, A; Huigsloot, M; Dihal, A A; Stevens, J L; Jaken, S; Mulder, G J

    2000-08-18

    Decreased phosphorylation of focal adhesion kinase and paxillin is associated with loss of focal adhesions and stress fibers and precedes the onset of apoptosis (van de Water, B., Nagelkerke, J. F., and Stevens, J. L. (1999) J. Biol. Chem. 274, 13328-13337). The cortical actin cytoskeletal network is also lost during apoptosis, yet little is known about the temporal relationship between altered phosphorylation of proteins that are critical in the regulation of this network and their potential cleavage by caspases during apoptosis. Adducins are central in the cortical actin network organization. Cisplatin caused apoptosis of renal proximal tubular epithelial cells, which was associated with the cleavage of alpha-adducin into a 74-kDa fragment; this was blocked by a general caspase inhibitor benzyloxycarbonyl-Val-Ala-Asp-fluoromethyl ketone (z-VAD-fmk). Hemagglutinin-tagged human alpha-adducin was cleaved into a similar 74-kDa fragment by caspase-3 in vitro but not by caspase-6 or -7. Asp-Arg-Val-Asp(29)-Glu, Asp-Ile-Val-Asp(208)-Arg, and Asp-Asp-Ser-Asp(633)-Ala were identified as the principal caspase-3 cleavage sites; Asp-Asp-Ser-Asp(633)-Ala was key in the formation of the 74-kDa fragment. Cisplatin also caused an increased phosphorylation of alpha-adducin and gamma-adducin in the MARCKS domain that preceded alpha-adducin cleavage and was associated with loss of adducins from adherens junctions; this was not affected by z-VAD-fmk. In conclusion, the data support a model in which increased phosphorylation of alpha-adducin due to cisplatin leads to dissociation from the cytoskeleton, a situation rendered irreversible by caspase-3-mediated cleavage of alpha-adducin at Asp-Asp-Ser-Asp(633)-Ala.

  16. Function of the two Xenopus smad4s in early frog development.

    PubMed

    Chang, Chenbei; Brivanlou, Ali H; Harland, Richard M

    2006-10-13

    Signals from the transforming growth factor beta family members are transmitted in the cell through specific receptor-activated Smads and a common partner Smad4. Two Smad4 genes (alpha and beta/10, or smad4 and smad4.2) have been isolated from Xenopus, and conflicting data are reported for Smad4beta/10 actions in mesodermal and neural induction. To further understand the functions of the Smad4s in early frog development, we analyzed their activities in detail. We report that Smad10 is a mutant form of Smad4beta that harbors a missense mutation of a conserved arginine to histidine in the MH1 domain. The mutation results in enhanced association of Smad10 with the nuclear transcription corepressor Ski and leads to its neural inducing activity through inhibition of bone morphogenetic protein (BMP) signaling. In contrast to Smad10, both Smad4alpha and Smad4beta enhanced BMP signals in ectodermal explants. Using antisense morpholino oligonucleotides (MOs) to knockdown endogenous Smad4 protein levels, we discovered that Smad4beta was required for both activin- and BMP-mediated mesodermal induction in animal caps, whereas Smad4alpha affected only the BMP signals. Neither Smad4 was involved directly in neural induction. Expression of Smad4beta-MO in early frog embryos resulted in reduction of mesodermal markers and defects in axial structures, which were rescued by either Smad4alpha or Smad4beta. Smad4alpha-MO induced only minor deficiency at late stages. As Smad4beta, but not Smad4alpha, is expressed at high levels maternally and during early gastrulation, our data suggest that although Smad4alpha and Smad4beta may have similar activities, they are differentially utilized during frog embryogenesis, with only Smad4beta being essential for mesoderm induction.

  17. Electrochemical formation of field emitters

    DOEpatents

    Bernhardt, A.F.

    1999-03-16

    Electrochemical formation of field emitters, particularly useful in the fabrication of flat panel displays is disclosed. The fabrication involves field emitting points in a gated field emitter structure. Metal field emitters are formed by electroplating and the shape of the formed emitter is controlled by the potential imposed on the gate as well as on a separate counter electrode. This allows sharp emitters to be formed in a more inexpensive and manufacturable process than vacuum deposition processes used at present. The fabrication process involves etching of the gate metal and the dielectric layer down to the resistor layer, and then electroplating the etched area and forming an electroplated emitter point in the etched area. 12 figs.

  18. Radial arrays of nano-electrospray ionization emitters and methods of forming electrosprays

    DOEpatents

    Kelly, Ryan T [West Richland, WA; Tang, Keqi [Richland, WA; Smith, Richard D [Richland, WA

    2010-10-19

    Electrospray ionization emitter arrays, as well as methods for forming electrosprays, are described. The arrays are characterized by a radial configuration of three or more nano-electrospray ionization emitters without an extractor electrode. The methods are characterized by distributing fluid flow of the liquid sample among three or more nano-electrospray ionization emitters, forming an electrospray at outlets of the emitters without utilizing an extractor electrode, and directing the electrosprays into an entrance to a mass spectrometry device. Each of the nano-electrospray ionization emitters can have a discrete channel for fluid flow. The nano-electrospray ionization emitters are circularly arranged such that each is shielded substantially equally from an electrospray-inducing electric field.

  19. Construction and measurements of a vacuum-swing-adsorption radon-mitigation system

    NASA Astrophysics Data System (ADS)

    Schnee, R. W.; Bunker, R.; Ghulam, G.; Jardin, D.; Kos, M.; Tenney, A. S.

    2013-08-01

    Long-lived alpha and beta emitters in the 222Rn decay chain on (and near) detector surfaces may be the limiting background in many experiments attempting to detect dark matter or neutrinoless double beta decay, and in screening detectors. In order to reduce backgrounds from radon-daughter plate-out onto the wires of the Beta Cage during its assembly, an ultra-low-radon cleanroom is being commissioned at Syracuse University using a vacuum-swing-adsorption radon-mitigation system. The radon filter shows ˜20× reduction at its output, from 7.47±0.56 to 0.37±0.12 Bq/m3, and the cleanroom radon activity meets project requirements, with a lowest achieved value consistent with that of the filter, and levels consistently < 2 Bq/m3.

  20. The Oxidation Rate of SiC in High Pressure Water Vapor Environments

    NASA Technical Reports Server (NTRS)

    Opila, Elizabeth J.; Robinson, R. Craig

    1999-01-01

    CVD SiC and sintered alpha-SiC samples were exposed at 1316 C in a high pressure burner rig at total pressures of 5.7, 15, and 25 atm for times up to 100h. Variations in sample emittance for the first nine hours of exposure were used to determine the thickness of the silica scale as a function of time. After accounting for volatility of silica in water vapor, the parabolic rate constants for Sic in water vapor pressures of 0.7, 1.8 and 3.1 atm were determined. The dependence of the parabolic rate constant on the water vapor pressure yielded a power law exponent of one. Silica growth on Sic is therefore limited by transport of molecular water vapor through the silica scale.

  1. Redefining relative biological effectiveness in the context of the EQDX formalism: implications for alpha-particle emitter therapy.

    PubMed

    Hobbs, Robert F; Howell, Roger W; Song, Hong; Baechler, Sébastien; Sgouros, George

    2014-01-01

    Alpha-particle radiopharmaceutical therapy (αRPT) is currently enjoying increasing attention as a viable alternative to chemotherapy for targeting of disseminated micrometastatic disease. In theory, αRPT can be personalized through pre-therapeutic imaging and dosimetry. However, in practice, given the particularities of α-particle emissions, a dosimetric methodology that accurately predicts the thresholds for organ toxicity has not been reported. This is in part due to the fact that the biological effects caused by α-particle radiation differ markedly from the effects caused by traditional external beam (photon or electron) radiation or β-particle emitting radiopharmaceuticals. The concept of relative biological effectiveness (RBE) is used to quantify the ratio of absorbed doses required to achieve a given biological response with alpha particles versus a reference radiation (typically a beta emitter or external beam radiation). However, as conventionally defined, the RBE varies as a function of absorbed dose and therefore a single RBE value is limited in its utility because it cannot be used to predict response over a wide range of absorbed doses. Therefore, efforts are underway to standardize bioeffect modeling for different fractionation schemes and dose rates for both nuclear medicine and external beam radiotherapy. Given the preponderant use of external beams of radiation compared to nuclear medicine in cancer therapy, the more clinically relevant quantity, the 2 Gy equieffective dose, EQD2(α/β), has recently been proposed by the ICRU. In concert with EQD2(α/β), we introduce a new, redefined RBE quantity, named RBE2(α/β), as the ratio of the two linear coefficients that characterize the α particle absorbed dose-response curve and the low-LET megavoltage photon 2 Gy fraction equieffective dose-response curve. The theoretical framework for the proposed new formalism is presented along with its application to experimental data obtained from irradiation of a breast cancer cell line. Radiobiological parameters are obtained using the linear quadratic model to fit cell survival data for MDA-MB-231 human breast cancer cells that were irradiated with either α particles or a single fraction of low-LET (137)Cs γ rays. From these, the linear coefficient for both the biologically effective dose (BED) and the EQD2(α/β) response lines were derived for fractionated irradiation. The standard RBE calculation, using the traditional single fraction reference radiation, gave RBE values that ranged from 2.4 for a surviving fraction of 0.82-6.0 for a surviving fraction of 0.02, while the dose-independent RBE2(4.6) value was 4.5 for all surviving fraction values. Furthermore, bioeffect modeling with RBE2(α/β) and EQD2(α/β) demonstrated the capacity to predict the surviving fraction of cells irradiated with acute and fractionated low-LET radiation, α particles and chronic exponentially decreasing dose rates of low-LET radiation. RBE2(α/β) is independent of absorbed dose for α-particle emitters and it provides a more logical framework for data reporting and conversion to equieffective dose than the conventional dose-dependent definition of RBE. Moreover, it provides a much needed foundation for the ongoing development of an α-particle dosimetry paradigm and will facilitate the use of tolerance dose data available from external beam radiation therapy, thereby helping to develop αRPT as a single modality as well as for combination therapies.

  2. Redefining Relative Biological Effectiveness in the Context of the EQDX Formalism: Implications for Alpha-Particle Emitter Therapy.

    PubMed

    Hobbs, Robert F; Howell, Roger W; Song, Hong; Baechler, Sébastien; Sgouros, George

    2013-12-30

    Alpha-particle radiopharmaceutical therapy (αRPT) is currently enjoying increasing attention as a viable alternative to chemotherapy for targeting of disseminated micrometastatic disease. In theory, αRPT can be personalized through pre-therapeutic imaging and dosimetry. However, in practice, given the particularities of α-particle emissions, a dosimetric methodology that accurately predicts the thresholds for organ toxicity has not been reported. This is in part due to the fact that the biological effects caused by α-particle radiation differ markedly from the effects caused by traditional external beam (photon or electron) radiation or β-particle emitting radiopharmaceuticals. The concept of relative biological effectiveness (RBE) is used to quantify the ratio of absorbed doses required to achieve a given biological response with alpha particles versus a reference radiation (typically a beta emitter or external beam radiation). However, as conventionally defined, the RBE varies as a function of absorbed dose and therefore a single RBE value is limited in its utility because it cannot be used to predict response over a wide range of absorbed doses. Therefore, efforts are underway to standardize bioeffect modeling for different fractionation schemes and dose rates for both nuclear medicine and external beam radiotherapy. Given the preponderant use of external beams of radiation compared to nuclear medicine in cancer therapy, the more clinically relevant quantity, the 2 Gy equieffective dose, EQD2(α/β), has recently been proposed by the ICRU. In concert with EQD2(α/β), we introduce a new, redefined RBE quantity, named RBE2(α/β), as the ratio of the two linear coefficients that characterize the α particle absorbed dose-response curve and the low-LET megavoltage photon 2 Gy fraction equieffective dose-response curve. The theoretical framework for the proposed new formalism is presented along with its application to experimental data obtained from irradiation of a breast cancer cell line. Radiobiological parameters are obtained using the linear quadratic model to fit cell survival data for MDA-MB-231 human breast cancer cells that were irradiated with either α particles or a single fraction of low-LET 137 Cs γ rays. From these, the linear coefficient for both the biologically effective dose (BED) and the EQD2(α/β) response lines were derived for fractionated irradiation. The standard RBE calculation, using the traditional single fraction reference radiation, gave RBE values that ranged from 2.4 for a surviving fraction of 0.82-6.0 for a surviving fraction of 0.02, while the dose-independent RBE2(4.6) value was 4.5 for all surviving fraction values. Furthermore, bioeffect modeling with RBE2(α/β) and EQD2(α/β) demonstrated the capacity to predict the surviving fraction of cells irradiated with acute and fractionated low-LET radiation, α particles and chronic exponentially decreasing dose rates of low-LET radiation. RBE2(α/β) is independent of absorbed dose for α-particle emitters and it provides a more logical framework for data reporting and conversion to equieffective dose than the conventional dose-dependent definition of RBE. Moreover, it provides a much needed foundation for the ongoing development of an α-particle dosimetry paradigm and will facilitate the use of tolerance dose data available from external beam radiation therapy, thereby helping to develop αRPT as a single modality as well as for combination therapies.

  3. Thermal emittance from ionization-induced trapping in plasma accelerators

    DOE PAGES

    Schroeder, C.  B.; Vay, J. -L.; Esarey, E.; ...

    2014-10-03

    The minimum obtainable transverse emittance (thermal emittance) of electron beams generated and trapped in plasma-based accelerators using laser ionization injection is examined. The initial transverse phase space distribution following ionization and passage through the laser is derived, and expressions for the normalized transverse beam emittance, both along and orthogonal to the laser polarization, are presented. Results are compared to particle-in-cell simulations. Ultralow emittance beams can be generated using laser ionization injection into plasma accelerators, and examples are presented showing normalized emittances on the order of tens of nm.

  4. High performance incandescent lighting using a selective emitter and nanophotonic filters

    NASA Astrophysics Data System (ADS)

    Leroy, Arny; Bhatia, Bikram; Wilke, Kyle; Ilic, Ognjen; Soljačić, Marin; Wang, Evelyn N.

    2017-09-01

    Previous approaches for improving the efficiency of incandescent light bulbs (ILBs) have relied on tailoring the emitted spectrum using cold-side interference filters that reflect the infrared energy back to the emitter while transmitting the visible light. While this approach has, in theory, potential to surpass light-emitting diodes (LEDs) in terms of luminous efficiency while conserving the excellent color rendering index (CRI) inherent to ILBs, challenges such as low view factor between the emitter and filter, high emitter (>2800 K) and filter temperatures and emitter evaporation have significantly limited the maximum efficiency. In this work, we first analyze the effect of non-idealities in the cold-side filter, the emitter and the view factor on the luminous efficiency. Second, we theoretically and experimentally demonstrate that the loss in efficiency associated with low view factors can be minimized by using a selective emitter (e.g., high emissivity in the visible and low emissivity in the infrared) with a filter. Finally, we discuss the challenges in achieving a high performance and long-lasting incandescent light source including the emitter and filter thermal stability as well as emitter evaporation.

  5. Close proximity electrostatic effect from small clusters of emitters

    NASA Astrophysics Data System (ADS)

    Dall'Agnol, Fernando F.; de Assis, Thiago A.

    2017-10-01

    Using a numerical simulation based on the finite-element technique, this work investigates the field emission properties from clusters of a few emitters at close proximity, by analyzing the properties of the maximum local field enhancement factor (γm ) and the corresponding emission current. At short distances between the emitters, we show the existence of a nonintuitive behavior, which consists of the increasing of γm as the distance c between the emitters decreases. Here we investigate this phenomenon for clusters with 2, 3, 4 and 7 identical emitters and study the influence of the proximity effect in the emission current, considering the role of the aspect ratio of the individual emitters. Importantly, our results show that peripheral emitters with high aspect-ratios in large clusters can, in principle, significantly increase the emitted current as a consequence only of the close proximity electrostatic effect (CPEE). This phenomenon can be seen as a physical mechanism to produce self-oscillations of individual emitters. We discuss new insights for understanding the nature of self-oscillations in emitters based on the CPEE, including applications to nanometric oscillators.

  6. Sharpening of field emitter tips using high-energy ions

    DOEpatents

    Musket, Ronald G.

    1999-11-30

    A process for sharpening arrays of field emitter tips of field emission cathodes, such as found in field-emission, flat-panel video displays. The process uses sputtering by high-energy (more than 30 keV) ions incident along or near the longitudinal axis of the field emitter to sharpen the emitter with a taper from the tip or top of the emitter down to the shank of the emitter. The process is particularly applicable to sharpening tips of emitters having cylindrical or similar (e.g., pyramidal) symmetry. The process will sharpen tips down to radii of less than 12 nm with an included angle of about 20 degrees. Because the ions are incident along or near the longitudinal axis of each emitter, the tips of gated arrays can be sharpened by high-energy ion beams rastered over the arrays using standard ion implantation equipment. While the process is particularly applicable for sharpening of arrays of field emitters in field-emission flat-panel displays, it can be effectively utilized in the fabrication of other vacuum microelectronic devices that rely on field emission of electrons.

  7. Experimental Study of Coherent Synchrotron Radiation in the Emittance Exchange Line at the A0-Photoinjector

    NASA Astrophysics Data System (ADS)

    Thangaraj, Jayakar C. T.; Thurman-Keup, R.; Johnson, A.; Lumpkin, A. H.; Edwards, H.; Ruan, J.; Santucci, J.; Sun, Y. E.; Church, M.; Piot, P.

    2010-11-01

    Next generation accelerators will require a high current, low emittance beam with a low energy spread. Such accelerators will employ advanced beam conditioning systems such as emittance exchangers to manipulate high brightness beams. One of the goals of the Fermilab A0 photoinjector is to investigate the transverse to longitudinal emittance exchange principle. Coherent synchrotron radiation could limit high current operation of the emittance exchanger. In this paper, we report on the preliminary experimental and simulation study of the coherent synchroton radiation (CSR) in the emittance exchange line at the A0 photoinjector.

  8. Synthesis, photophysical and electrochemical properties of a blue emitter with binaphthalene and carbazole units.

    PubMed

    Guo, Lixia; Wang, Xiaoju; Feng, Liheng

    2018-08-05

    A blue emitter, 3,3'-(2,2'-dimethoxy-[1,1'-binaphthalene]-6,6'-diyl)bis(9-benzyl-9H-carbazole), was synthesized by Suzuki coupling reaction. The photophysical properties of the emitter in solution were firstly investigated by UV-Vis absorption and fluorescence emission techniques. The results indicate that the emitter has excellent optical and electron transfer properties. The maximum absorption and emission peaks of the emitter are 302 nm and 406 nm with 67.4% fluorescence quantum yield in chloroform, respectively. Thermal stability study reveals that the emitter has a good thermal stability (Td > 330 °C, Tg > 160 °C). Electrochemical Redox properties of the emitters were measured by cyclic voltammetry, and the energy gaps of highest occupied molecular orbital and the lowest unoccupied molecular orbital levels are in good agreement with the results of theoretical calculation. Furthermore, the multilayer electrochemcial device with the emitter was fabricated and its properties were explored. The wavelength of electroluminescence for the device with this emitter locates at 428 nm. These results indicate the emitter as a deep blue-emitting material has promising application in organic light-emitting diode devices. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Free Body Dynamics of a Spinning Cylinder With Planar Restraint (a.k.a. Barrel of Fun)

    NASA Technical Reports Server (NTRS)

    Moraru, Laurentiu; Dimofte, Florin; Hendricks, Robert C.

    2006-01-01

    The dynamic motion of a cylinder on a floor or hard surface is both entertaining and instructive. With maintenance torques, motion can be sustained and controlled as illustrated in a video clip that can be viewed in the PDF file of this document. The analysis of such a cylinder with and without end caps is burned on rotation about its center of mass and restrained by a plane normal to the axis passing through its center of mass at an angle alpha. For small values of alpha, the governing equations are simplified, and for symmetric bodies, stability requires rotation greater than [2 square root of(JWL*)]/J(sub X), where J is the transverse mass moment of inertia, W is the weight of the cylinder, L* is the cylinder length from the base to the center of mass, and JX is the mass moment of inertia about the longitudinal axis OX of the barrel. Comparisons to data are made and some applications are discussed.

  10. Identification of high-mannose and multiantennary complex-type N-linked glycans containing alpha-galactose epitopes from Nurse shark IgM heavy chain.

    PubMed

    Harvey, David J; Crispin, Max; Moffatt, Beryl E; Smith, Sylvia L; Sim, Robert B; Rudd, Pauline M; Dwek, Raymond A

    2009-11-01

    MALDI-TOF mass spectrometry, negative ion nano-electrospray MS/MS and exoglycosidase digestion were used to identify 36 N-linked glycans from 19S IgM heavy chain derived from the nurse shark (Ginglymostoma cirratum). The major glycan was the high-mannose compound, Man(6)GlcNAc(2) accompanied by small amounts of Man(5)GlcNAc(2), Man(7)GlcNAc(2) and Man(8)GlcNAc(2). Bi- and tri-antennary (isomer with a branched 3-antenna) complex-type glycans were also abundant, most contained a bisecting GlcNAc residue (beta1-->4-linked to the central mannose) and with varying numbers of alpha-galactose residues capping the antennae. Small amounts of monosialylated glycans were also found. This appears to be the first comprehensive study of glycosylation in this species of animal. The glycosylation pattern has implications for the mechanism of activation of the complement system by nurse shark IgM.

  11. The ionosphere of Uranus - A myriad of possibilities

    NASA Astrophysics Data System (ADS)

    Chandler, M. O.; Waite, J. H.

    1986-01-01

    A one-dimensional model has been used to study the effects of exospheric temperature, methane and water influx, ionospheric outflow, and electron precipitation on the composition and structure of the ionosphere of Uranus. Peak ion concentrations range from 1000 to 1 million per cu cm with a wide variation in peak altitude, which depends strongly on the exospheric temperature. In all the cases considered, H(+) is the major ion in the topside ionosphere. At altitudes near or below the peak, H3(+) and CH5(+) can dominate, depending on the magnitude of CH4 and H2O influx. Atomic hydrogen column depths above the methane absorbing layer exceed 10 to the 17th per sq cm and can produce large (400 R) emissions of resonantly scattered Lyman-alpha. In the sunlit polar cap, electron precipitation with energy fluxes of 0.6 to 1.0 erg/sq cm s results in direct production of Lyman-alpha emissions that exceed 1 kR.

  12. Enzymatic transformation of nonfood biomass to starch

    PubMed Central

    You, Chun; Chen, Hongge; Myung, Suwan; Sathitsuksanoh, Noppadon; Ma, Hui; Zhang, Xiao-Zhou; Li, Jianyong; Zhang, Y.-H. Percival

    2013-01-01

    The global demand for food could double in another 40 y owing to growth in the population and food consumption per capita. To meet the world’s future food and sustainability needs for biofuels and renewable materials, the production of starch-rich cereals and cellulose-rich bioenergy plants must grow substantially while minimizing agriculture’s environmental footprint and conserving biodiversity. Here we demonstrate one-pot enzymatic conversion of pretreated biomass to starch through a nonnatural synthetic enzymatic pathway composed of endoglucanase, cellobiohydrolyase, cellobiose phosphorylase, and alpha-glucan phosphorylase originating from bacterial, fungal, and plant sources. A special polypeptide cap in potato alpha-glucan phosphorylase was essential to push a partially hydrolyzed intermediate of cellulose forward to the synthesis of amylose. Up to 30% of the anhydroglucose units in cellulose were converted to starch; the remaining cellulose was hydrolyzed to glucose suitable for ethanol production by yeast in the same bioreactor. Next-generation biorefineries based on simultaneous enzymatic biotransformation and microbial fermentation could address the food, biofuels, and environment trilemma. PMID:23589840

  13. Amorphous-diamond electron emitter

    DOEpatents

    Falabella, Steven

    2001-01-01

    An electron emitter comprising a textured silicon wafer overcoated with a thin (200 .ANG.) layer of nitrogen-doped, amorphous-diamond (a:D-N), which lowers the field below 20 volts/micrometer have been demonstrated using this emitter compared to uncoated or diamond coated emitters wherein the emission is at fields of nearly 60 volts/micrometer. The silicon/nitrogen-doped, amorphous-diamond (Si/a:D-N) emitter may be produced by overcoating a textured silicon wafer with amorphous-diamond (a:D) in a nitrogen atmosphere using a filtered cathodic-arc system. The enhanced performance of the Si/a:D-N emitter lowers the voltages required to the point where field-emission displays are practical. Thus, this emitter can be used, for example, in flat-panel emission displays (FEDs), and cold-cathode vacuum electronics.

  14. Rare Earth Doped Yttrium Aluminum Garnet (YAG) Selective Emitters

    NASA Technical Reports Server (NTRS)

    Chubb, Donald L.; Pal, AnnaMarie T.; Patton, Martin O.; Jenkins, Phillip P.

    1999-01-01

    As a result of their electron structure, rare earth ions in crystals at high temperature emit radiation in several narrow bands rather than in a continuous blackbody manner. This study presents a spectral emittance model for films and cylinders of rare earth doped yttrium aluminum garnets. Good agreement between experimental and theoretical film spectral emittances was found for erbium and holmium aluminum garnets. Spectral emittances of films are sensitive to temperature differences across the film. For operating conditions of interest, the film emitter experiences a linear temperature variation whereas the cylinder emitter has a more advantageous uniform temperature. Emitter efficiency is also a sensitive function of temperature. For holminum aluminum garnet film the efficiency is 0.35 at 1446K but only 0.27 at 1270 K.

  15. Method for photon activation positron annihilation analysis

    DOEpatents

    Akers, Douglas W.

    2006-06-06

    A non-destructive testing method comprises providing a specimen having at least one positron emitter therein; determining a threshold energy for activating the positron emitter; and determining whether a half-life of the positron emitter is less than a selected half-life. If the half-life of the positron emitter is greater than or equal to the selected half-life, then activating the positron emitter by bombarding the specimen with photons having energies greater than the threshold energy and detecting gamma rays produced by annihilation of positrons in the specimen. If the half-life of the positron emitter is less then the selected half-life, then alternately activating the positron emitter by bombarding the specimen with photons having energies greater then the threshold energy and detecting gamma rays produced by positron annihilation within the specimen.

  16. Formation and self-organization kinetics of alpha-CD/PEO-based pseudo-polyrotaxanes in water. A specific behavior at 30 degrees C.

    PubMed

    Travelet, Christophe; Schlatter, Guy; Hébraud, Pascal; Brochon, Cyril; Lapp, Alain; Hadziioannou, Georges

    2009-08-04

    alpha-Cyclodextrins (alpha-CDs) have the ability to form inclusion complexes with poly(ethylene oxide) (PEO) polymer chains. These pseudo-polyrotaxanes (PPRs) can be obtained by quenching an alpha-CD/PEO mixture in water from 70 degrees C down to a lower temperature (typically in the range from 5 to 30 degrees C) thanks to favorable interactions between alpha-CD cavities and PEO chains. Moreover, starting from a liquid alpha-CD/PEO mixture at a total mass fraction of 15% w/w at 70 degrees C, the formation of PPRs with time at a lower temperature induces a white physical gel with time, and phase separation is observed. We established that PPR molecules are exclusively found in the precipitated phase although unthreaded alpha-CD molecules and unthreaded PEO chains are in the liquid phase. At 30 degrees C, the physical gel formation is much slower than at 5 degrees C. At 30 degrees C, we established that, in a first step, alpha-CDs thread onto PEO chains, forming PPR molecules which are not in good solvent conditions in water. At a higher length scale, rapid aggregation of the PPR molecules occurs, and threaded alpha-CD-based nanocylinders form (cylinder length L = 5.7 nm and cylinder radius R = 4.7 nm). At a higher length scale, alpha-CD-based nanocylinders associate in a Gaussian way, engendering the formation of precipitated domains which are responsible for the high turbidity of the studied system. At the end of this first step (i.e., after 20 min), the system still remains liquid and the PPRs are totally formed. Then, in a second step (i.e., after 150 min), the system undergoes its reorganization characterized by a compacity increase of the precipitated domains and forms a physical gel. We found that PPRs are totally formed after 20 min at 30 degrees C and that the system stays in a nongel state up to 150 min. This opens new perspectives regarding the PPR chemical modification: between these two characteristic times, we can easily envisage an efficient chemical modification of the PPR molecules in water, as for instance an end-capping reaction leading to the synthesis of polyrotaxanes.

  17. Monte Carlo simulation of age-dependent radiation dose from alpha- and beta-emitting radionuclides to critical trabecular bone and bone marrow targets

    NASA Astrophysics Data System (ADS)

    Dant, James T.; Richardson, Richard B.; Nie, Linda H.

    2013-05-01

    Alpha (α) particles and low-energy beta (β) particles present minimal risk for external exposure. While these particles can induce leukemia and bone cancer due to internal exposure, they can also be beneficial for targeted radiation therapies. In this paper, a trabecular bone model is presented to investigate the radiation dose from bone- and marrow-seeking α and β emitters to different critical compartments (targets) of trabecular bone for different age groups. Two main issues are addressed with Monte Carlo simulations. The first is the absorption fractions (AFs) from bone and marrow to critical targets within the bone for different age groups. The other issue is the application of 223Ra for the radiotherapy treatment of bone metastases. Both a static model and a simulated bone remodeling process are established for trabecular bone. The results show significantly lower AFs from radionuclide sources in the bone volume to the peripheral marrow and the haematopoietic marrow for adults than for newborns and children. The AFs from sources on the bone surface and in the bone marrow to peripheral marrow and haematopoietic marrow also varies for adults and children depending on the energy of the particles. Regarding the use of 223Ra as a radionuclide for the radiotherapy of bone metastases, the simulations show a significantly higher dose from 223Ra and its progeny in forming bone to the target compartment of bone metastases than that from two other more commonly used β-emitting radiopharmaceuticals, 153Sm and 89Sr. There is also a slightly lower dose from 223Ra in forming bone to haematopoietic marrow than that from 153Sm and 89Sr. These results indicate a higher therapy efficiency and lower marrow toxicity from 223Ra and its progeny. In conclusion, age-related changes in bone dimension and cellularity seem to significantly affect the internal dose from α and β emitters in the bone and marrow to critical targets, and 223Ra may be a more efficient radiopharmaceutical for the treatment of bone metastases than 153Sm and 89Sr, if the diffusion of 219Rn to the bone marrow is insignificant.

  18. Can Gas Outflows Explain The Strong Lyα Emission Of Lyman Alpha Emitters?

    NASA Astrophysics Data System (ADS)

    Hashimoto, Takuya; Ouchi, M.; Shimasaku, K.; Nakajima, K.; Ono, Y.; Rauch, M.

    2012-05-01

    Lyman alpha emitters (LAEs) are galaxies commonly seen at high redshift, probably playing an important role in galaxy evolution as building blocks of massive galaxies. The most interesting feature of LAEs is strong Lyα emission, because Lyα photons produced in a galaxy are expected to be easily absorbed by dust in the ISM before escaping the galaxy due to their resonant nature. Previous studies have suggested that outflow may help their escape thanks to reduced cross sections of outflowing (ie, redshifted) neutral hydrogen atoms. Although the presence of outflows can be examined from the offset of the Lyα emission from the systemic velocity defined by Hα emission, there are only four LAEs with reliable detection of Hα emission. We present the results of Magellan/MMIRS and Keck/NIRSPEC spectroscopic observations of five LAEs at z˜2.2 from our wide-field narrow-band survey with Subaru/Suprime-Cam. We successfully detect Hα emission for five objects. After eliminating an AGN contaminated object, we measure the velocityoffset between Lyα and Hα (Δ v_Lyα) for the remaining four, to find that three have a positive offset, suggesting an outflow. Since three among the four from the the literature also have an outflow, we conclude that ˜75% of LAEs have an outflow, with velocities of 75-280 km/s. We then use these eight LAEs to examine how the Lyα strength defined by Lyα escape fraction (f_esc) and/or Lyα equivalent width (EW(Lyα)) depend on other physical quantities including those derived from SED fitting. Contrary to our expectation, we find that both f_esc and EW(Lyα) decrease with Δ v_Lyα. Thus, although LAEs do have outflow, high outflow velocities are not the primary cause of strong Lyα emission. We also find that the Lyα strength does not depend on E(B-V). However, we find that objects with a clumpier gas distribution may have higher f_esc.

  19. Emittance Measurements Relevant to a 250 W(sub t) Class RTPV Generator for Space Exploration

    NASA Technical Reports Server (NTRS)

    Wolford, Dave; Chubb, Donald; Clark, Eric; Pal, Anna Maria; Scheiman, Dave; Colon, Jack

    2009-01-01

    A proposed 250 Wt Radioisotope Thermophotovoltaic (RTPV) power system for utilization in lunar exploration and the subsequent exploration of Mars is described. Details of emitter selection are outlined for use in a maintenance free power supply that is productive over a 14-year mission life. Thorough knowledge of a material s spectral emittance is essential for accurate modeling of the RTPV system. While sometimes treated as a surface effect, emittance involves radiation from within a material. This creates a complex thermal gradient which is a combination of conductive and radiative heat transfer mechanisms. Emittance data available in the literature is a valuable resource but it is particular to the test sample s physical characteristics and the test environment. Considerations for making spectral emittance measurements relevant to RTPV development are discussed. Measured spectral emittance data of refractory emitter materials is given. Planned measurement system modifications to improve relevance to the current project are presented.

  20. Selective far-field addressing of coupled quantum dots in a plasmonic nanocavity.

    PubMed

    Tang, Jianwei; Xia, Juan; Fang, Maodong; Bao, Fanglin; Cao, Guanjun; Shen, Jianqi; Evans, Julian; He, Sailing

    2018-04-27

    Plasmon-emitter hybrid nanocavity systems exhibit strong plasmon-exciton interactions at the single-emitter level, showing great potential as testbeds and building blocks for quantum optics and informatics. However, reported experiments involve only one addressable emitting site, which limits their relevance for many fundamental questions and devices involving interactions among emitters. Here we open up this critical degree of freedom by demonstrating selective far-field excitation and detection of two coupled quantum dot emitters in a U-shaped gold nanostructure. The gold nanostructure functions as a nanocavity to enhance emitter interactions and a nanoantenna to make the emitters selectively excitable and detectable. When we selectively excite or detect either emitter, we observe photon emission predominantly from the target emitter with up to 132-fold Purcell-enhanced emission rate, indicating individual addressability and strong plasmon-exciton interactions. Our work represents a step towards a broad class of plasmonic devices that will enable faster, more compact optics, communication and computation.

  1. Benchmarking of measurement and simulation of transverse rms-emittance growth

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jeon, Dong-O

    2008-01-01

    Transverse emittance growth along the Alvarez DTL section is a major concern with respect to the preservation of beam quality of high current beams at the GSI UNILAC. In order to define measures to reduce this growth appropriated tools to simulate the beam dynamics are indispensable. This paper is about the benchmarking of three beam dynamics simulation codes, i.e. DYNAMION, PARMILA, and PARTRAN against systematic measurements of beam emittances for different machine settings. Experimental set-ups, data reduction, the preparation of the simulations, and the evaluation of the simulations will be described. It was found that the measured 100%-rmsemittances behind themore » DTL exceed the simulated values. Comparing measured 90%-rms-emittances to the simulated 95%-rms-emittances gives fair to good agreement instead. The sum of horizontal and vertical emittances is even described well by the codes as long as experimental 90%-rmsemittances are compared to simulated 95%-rms-emittances. Finally, the successful reduction of transverse emittance growth by systematic beam matching is reported.« less

  2. Measuring alcohol-related consequences and motives among students attending Historically Black Colleges and Universities.

    PubMed

    Messina, Bryan G; Tseng, Andy; Correia, Christopher J

    2015-07-01

    College student drinkers have the propensity to engage in heavy alcohol consumption. These consumption patterns can be problematic given the well-established relationship between heavy drinking and negative consequences of alcohol consumption. Though the research on college student drinking is abundant, much of the work conducted has been with Caucasian samples and less so with African American samples or at Historically Black Colleges and Universities (HBCUs). The current paper assessed the internal reliability and concurrent validity of two popular measures of alcohol related negative consequences (CAPS-r and YAACQ) and a measure of drinking motives (DMQ-R) within a HBCU sample. Total scores for the CAPS-r and YAACQ and all five subscales of the DMQ-R were internally reliable as determined by Cronbach's alpha. Correlations and regressions established concurrent validity for both measures of negative consequences as well as the subscales for the DMQ-R. Findings support the use of these measures in the assessment of negative consequences and motivations for alcohol consumption within a HBCU population. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Emitter utilization in heterojunction bipolar transistors

    NASA Astrophysics Data System (ADS)

    Quach, T.; Jenkins, T.; Barrette, J.; Bozada, C.; Cerny, C.; Desalvo, G.; Dettmer, R.; Ebel, J.; Gillespie, J.; Havasy, C.; Ito, C.; Nakano, K.; Pettiford, C.; Sewell, J.; Via, D.; Anholt, R.

    1997-09-01

    We compare measured collector current densities, cutoff frequencies ( ft), and transducer gains for thermally shunted heterojunction bipolar transistors with 2-16 μm emitter dot diameters or 2-8 μm emitter bar widths with models of the emitter utilization factors. Models that do not take emitter resistance into account predict that the d.c. utilization factors are below 0.7 for collector current densities greater than 6 × 10 4 A cm -2 and emitter diameters or widths greater than 8 μm. However, because the current gains are compressed by the emitter resistances at those current densities, the measured utilization factors are close to 1, which agrees with models that include emitter resistance. A.c. utilization factors are evident in the transistor Y parameters. For example, Re|Y 21z.sfnc drops off at high frequencies more steeply in HBTs with large emitter diameters or widths than in small ones. However, measured data shows that the HBT a.c. current gains h21 or ft values are not influenced by the a.c. utilization factor. A.c. utilization effects on HBT performance parameters such as small signal and power gains, output power, and power added efficiency are also examined.

  4. Proecdysial changes in serum ecdysone titers, gastrolith formation, and limb regeneration following molt induction by limb autotomy and/or eyestalk removal in the land crab, Gecarcinus lateralis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCarthy, J.F.; Skinner, D.M.

    1977-01-01

    The changes in serum ecdysone titers, gastrolith deposition, and limb regeneration were monitored at each stage of the molt cycle in the land crab, Gecarcinus lateralis. Animals were induced to molt by multiple-limb autotomy or eyestalk removal. The presence of ..cap alpha..-ecdysone and b-ecdysone (20-hydroxyecdysone) in the animals' serum was demonstrated chromatographically. ..beta..-ecdysone was the major circulating ecdysone, while ..cap alpha..-ecdysone was present only at very low concentrations. Four other components reacting with the ecdysone antiserum were separated chromatographically; one of these, a nonpolar compound, became a major component of the serum ecdysones at the time of maximum hormone titers.more » Ecdysone titers in the serum remained at the level characteristic of intermolt (approximately 10 ng/ml) during basal regeneration and rose linearly during the premolt period, reaching a maximum when regeneration of limbs had ceased and exoskeleton was deposited. Ecdysone decreased during stages D/sub 3/ and D/sub 4/, approaching intermolt levels at the time of ecdysis, where they remained through postmolt stages A and B. The patterns of premolt changes in ecdysone titers, gastroliths, and regeneration were very similar in ''normal'' animals (stimulated to molt by the loss of eight pereiopods) and in animals without eyestalks; however, in crabs without eyestalks, the changes were completed in about half the time as in crabs with eyestalks. Basal regeneration is associated with low ecdysone levels even in crabs without eyestalks. The normal sequence of proecdysial events is not initiated until the completion of basal regeneration. It is suggested that there exists a yet-unidentified mechanism outside the eyestalk capable of preventing increases in ecdysone titers while limbs engage in basal regeneration.« less

  5. Interaction of tachykinins with their receptors studied with cyclic analogues of substance P and neurokinin B

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ploux, O.; Lavielle, S.; Chassaing, G.

    1987-11-01

    The activities of two groups of cyclic agonists of substance P (SP) have been studied. The disulfide bridge constraints have been designed on the basis of conformational studies on SP and physalaemin indicating an ..cap alpha..-helical structure for the core of these two tachykinins (group I) and a folding of the C-terminal carboxamide towards the side chains of the glutamines 5 and 6 (group II). Only peptides simulating the ..cap alpha..-helix present substantial potencies. (Cys/sup 3,6/)SP is as active as SP in inhibiting /sup 125/I-labeled Bolton and Hunter SP-specific binding on rat brain synaptosomes and on dog carotid bioassay, twomore » assays specific for the neurokinin 1 receptor. Moreover, (Cys/sup 3,6/)SP is a potent as neurokinin B in inhibiting /sup 125/I-labeled Bolton and Hunter eledoisin-specific binding on rat cortical synaptosomes as well as in stimulating rat portal vein, two tests specific for the neurokinin 3 receptor. Interestingly, in contrast to neurokinin B, (Cys/sup 3,6/)SP is a weak agonist of the neurokinin 2 receptor subtype, as evidenced by its binding potency in inhibiting /sup 3/H-labeled neurokinin A-specific binding on rat duodenum and in inducing the contractions of the rabbit pulmonary artery, a neurokinin 2-type bioassay. To increase the specificity of the cyclic analogue (Cys/sup 3,6/)SP positions 8 and 9 were modified. Collectively, these results suggest that the neurokinin 1 and neurokinin 3 tachykinin receptors may recognize a similar three-dimensional structure of the core of the tachykinins. Different orientations of the common C-terminal tripeptide may be related to the selectivity for the different receptor subtypes.« less

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Inbar, S.; Linschitz, H.; Cohen, S.G.

    Nanosecond flash photolysis, steady irradiation, and deuterium substitution studies have been carried out on solutions of benzophenone with added reductants. Quantum yields (phi/sub ketyl/) for reduction in benzene of benzophenone triplet to ketyl radical, based on phi = 2 for benzhydrol (I), were approx. 1 for cyclohexane (II), tert-butylamine (III), 2-aminobutane (IV), cyclohexylamine (V), di-n-propylamine (VI), and triethylamine (VII), approx. 0.7 for 1,4-diazabicyclo(2.2.2)octane (VIII), and approx. 0 for tert-butyl alcohol (IX). Thus, quenching, without radical formation by H abstraction from N and/or ..cap alpha..-C, does not occur with common aliphatic amines but does with Dabco (VIII). The latter quenching ismore » markedly increased by small additions of acetonitrile; the flash spectrum from this compound indicates formation of a triplet amine CT complex or radical ion pair. Triplet-reductant interaction rate constants, k/sur ir/, are high for the amines (approx. 10/sup 8/-10/sup 9/ M/sup -1/ s/sup -1/) but also show significant deuterium kinetic isotope effects: 1.9 with III-N-d/sub 2/; 1.4 with IV-N-d/sub 2/; 1.2-1.3 with IV-..cap alpha..-C-d. It is proposed that k/sub ir/ measures H atom abstraction, favored in the transition state by an initial charge-transfer interaction. Overall steady irradiation quantum yields of reduction by amines, phi/sub Red/, are much lower than phi/sub ketyl/. This is attributed to disproportionationreactions of ketyl and alkylaminyl radicals for primary and secondary amines, and, possibly, aminoalkyl radicals for tertiary amines. In the case of tert-butylamine, the rate constant for disproportionation is obtained from the decay kinetics of ketyl radical and leads to phi/sub Red/ in agreement with that directly measured.« less

  7. The Effect of an Offset Polar Cap Dipolar Magnetic Field on the Modeling of the Vela Pulsar's Gamma-Ray Light Curves

    NASA Technical Reports Server (NTRS)

    Barnard, M.; Venter, C.; Harding, A. K.

    2016-01-01

    We performed geometric pulsar light curve modeling using static, retarded vacuum, and offset polar cap (PC) dipole B-fields (the latter is characterized by a parameter epsilon), in conjunction with standard two-pole caustic (TPC) and outer gap (OG) emission geometries. The offset-PC dipole B-field mimics deviations from the static dipole (which corresponds to epsilon equals 0). In addition to constant-emissivity geometric models, we also considered a slot gap (SG) E-field associated with the offset-PC dipole B-field and found that its inclusion leads to qualitatively different light curves. Solving the particle transport equation shows that the particle energy only becomes large enough to yield significant curvature radiation at large altitudes above the stellar surface, given this relatively low E-field. Therefore, particles do not always attain the radiation-reaction limit. Our overall optimal light curve fit is for the retarded vacuum dipole field and OG model, at an inclination angle alpha equals 78 plus or minus 1 degree and observer angle zeta equals 69 plus 2 degrees or minus 1 degree. For this B-field, the TPC model is statistically disfavored compared to the OG model. For the static dipole field, neither model is significantly preferred. We found that smaller values of epsilon are favored for the offset-PC dipole field when assuming constant emissivity, and larger epsilon values favored for variable emissivity, but not significantly so. When multiplying the SG E-field by a factor of 100, we found improved light curve fits, with alpha and zeta being closer to best fits from independent studies, as well as curvature radiation reaction at lower altitudes.

  8. Radiosensitivity of Prostate Cancer Cell Lines for Irradiation from Beta Particle-emitting Radionuclide ¹⁷⁷Lu Compared to Alpha Particles and Gamma Rays.

    PubMed

    Elgqvist, Jörgen; Timmermand, Oskar Vilhelmsson; Larsson, Erik; Strand, Sven-Erik

    2016-01-01

    The purpose of the present study was to investigate the radiosensitivity of the prostate cancer cell lines LNCaP, DU145, and PC3 when irradiated with beta particles emitted from (177)Lu, and to compare the effect with irradiation using alpha particles or gamma rays. Cells were irradiated with beta particles emitted from (177)Lu, alpha particles from (241)Am, or gamma rays from (137)Cs. A non-specific polyclonal antibody was labeled with (177)Lu and used to irradiate cells in suspension with beta particles. A previously described in-house developed alpha-particle irradiator based on a (241)Am source was used to irradiate cells with alpha particles. External gamma-ray irradiation was achieved using a standard (137)Cs irradiator. Cells were irradiated to absorbed doses equal to 0, 0.5, 1, 2, 4, 6, 8, or 10 Gy. The absorbed doses were calculated as mean absorbed doses. For evaluation of cell survival, the tetrazolium-based WST-1 assay was used. After irradiation, WST-1 was added to the cell solutions, incubated, and then measured for level of absorbance at 450 nm, indicating the live and viable cells. LNCaP, DU145, and PC3 cell lines all had similar patterns of survival for the different radiation types. No significant difference in surviving fractions were observed between cells treated with beta-particle and gamma-ray irradiation, represented for example by the surviving fraction values (mean±SD) at 2, 6, and 10 Gy (SF2, SF6, and SF10) for DU145 after beta-particle irradiation: 0.700±0.090, 0.186±0.050 and 0.056±0.010, respectively. A strong radiosensitivity to alpha particles was observed, with SF2 values of 0.048±0.008, 0.018±0.006 and 0.015±0.005 for LNCaP, DU145, and PC3, respectively. The surviving fractions after irradiation using beta particles or gamma rays did not differ significantly at the absorbed dose levels and dose rates used. Irradiation using alpha particles led to a high level of cell killing. The results show that the beta-particle emitter (177)Lu as well as alpha-particles are both good candidates for radionuclide-therapy applications in the treatment of prostate cancer. Copyright© 2016 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  9. Ion Motion Induced Emittance Growth of Matched Electron Beams in Plasma Wakefields.

    PubMed

    An, Weiming; Lu, Wei; Huang, Chengkun; Xu, Xinlu; Hogan, Mark J; Joshi, Chan; Mori, Warren B

    2017-06-16

    Plasma-based acceleration is being considered as the basis for building a future linear collider. Nonlinear plasma wakefields have ideal properties for accelerating and focusing electron beams. Preservation of the emittance of nano-Coulomb beams with nanometer scale matched spot sizes in these wakefields remains a critical issue due to ion motion caused by their large space charge forces. We use fully resolved quasistatic particle-in-cell simulations of electron beams in hydrogen and lithium plasmas, including when the accelerated beam has different emittances in the two transverse planes. The projected emittance initially grows and rapidly saturates with a maximum emittance growth of less than 80% in hydrogen and 20% in lithium. The use of overfocused beams is found to dramatically reduce the emittance growth. The underlying physics that leads to the lower than expected emittance growth is elucidated.

  10. Structural features of the exocellular polysaccharides of Mycobacterium tuberculosis.

    PubMed Central

    Lemassu, A; Daffé, M

    1994-01-01

    The cell envelope which surrounds pathogenic mycobacteria is postulated to be a defence barrier against phagocytic cells and its outermost constituents have a tendency to accumulate in the culture medium. The present work demonstrates that the exocellular material of Mycobacterium tuberculosis contains large amounts of polysaccharides with only traces, if any at all, of lipids. Three types of polysaccharides were purified by anion-exchange and gel-filtration chromatography; all were found to be neutral compounds devoid of acyl substituents. They consisted of D-glucan, D-arabino-D-mannan and D-mannan, which were eluted from gel-filtration columns in positions corresponding to molecular masses of 123, 13 and 4 kDa respectively. Their predominant structural features were determined by the characterization of the per-O-methyl derivatives of enzymic, acetolysis and Smith-degradation products and by 1H- and 13C-n.m.r. spectroscopy of the purified polysaccharides, using mono- and two-dimensional homonuclear chemical-shift correlated spectroscopy and two-dimensional heteronuclear (1H/13C) spectroscopy. The glucan which represented up to 90% of the polysaccharides was composed of repeating units of five or six-->4-alpha-D-Glcp-1--> residues and a -->4-alpha-D-Glcp substituted at position 6 with an alpha-D-Glcp, indicating a glycogen-like highly branched structure not related to the so-called polysaccharide-II previously identified in tuberculin. The arabinomannan consisted of a mannan segment composed of a -->6-alpha-D-Man-1--> core substituted at some positions 2 with an alpha-D-Manp. The arabinan termini of the arabinomannan were found to be extensively capped with mannosyl residues. The possibility that these polysaccharides contribute to the persistence of the tubercle bacillus in the macrophage by molecular mimicry is discussed. PMID:8297342

  11. Structural features of the exocellular polysaccharides of Mycobacterium tuberculosis.

    PubMed

    Lemassu, A; Daffé, M

    1994-01-15

    The cell envelope which surrounds pathogenic mycobacteria is postulated to be a defence barrier against phagocytic cells and its outermost constituents have a tendency to accumulate in the culture medium. The present work demonstrates that the exocellular material of Mycobacterium tuberculosis contains large amounts of polysaccharides with only traces, if any at all, of lipids. Three types of polysaccharides were purified by anion-exchange and gel-filtration chromatography; all were found to be neutral compounds devoid of acyl substituents. They consisted of D-glucan, D-arabino-D-mannan and D-mannan, which were eluted from gel-filtration columns in positions corresponding to molecular masses of 123, 13 and 4 kDa respectively. Their predominant structural features were determined by the characterization of the per-O-methyl derivatives of enzymic, acetolysis and Smith-degradation products and by 1H- and 13C-n.m.r. spectroscopy of the purified polysaccharides, using mono- and two-dimensional homonuclear chemical-shift correlated spectroscopy and two-dimensional heteronuclear (1H/13C) spectroscopy. The glucan which represented up to 90% of the polysaccharides was composed of repeating units of five or six-->4-alpha-D-Glcp-1--> residues and a -->4-alpha-D-Glcp substituted at position 6 with an alpha-D-Glcp, indicating a glycogen-like highly branched structure not related to the so-called polysaccharide-II previously identified in tuberculin. The arabinomannan consisted of a mannan segment composed of a -->6-alpha-D-Man-1--> core substituted at some positions 2 with an alpha-D-Manp. The arabinan termini of the arabinomannan were found to be extensively capped with mannosyl residues. The possibility that these polysaccharides contribute to the persistence of the tubercle bacillus in the macrophage by molecular mimicry is discussed.

  12. Prototype of a subsurface drip irrigation emitter: Manufacturing, hydraulic evaluation and experimental analyses

    NASA Astrophysics Data System (ADS)

    Souza, Wanderley De Jesus; Rodrigues Sinobas, Leonor; Sánchez, Raúl; Arriel Botrel, Tarlei; Duarte Coelho, Rubens

    2013-04-01

    Root and soil intrusion into the conventional emitters is one of the major disadvantages to obtain a good uniformity of water application in subsurface drip irrigation (SDI). In the last years, there have been different approaches to reduce these problems such as the impregnation of emitters with herbicide, and the search for an emitter geometry impairing the intrusion of small roots. Within the last this study, has developed and evaluated an emitter model which geometry shows specific physical features to prevent emitter clogging. This work was developed at the Biosystems Engineering Department at ESALQ-USP/Brazil, and it is a part of a research in which an innovated emitteŕs model for SDI has been developed to prevent root and soil particles intrusion. An emitter with a mechanical-hydraulic mechanism (opening and closing the water outlet) for SDI was developed and manufactured using a mechanical lathe process. It was composed by a silicon elastic membrane a polyethylene tube and a Vnyl Polychloride membrane protector system. In this study the performance of the developed prototype was assessed in the laboratory and in the field conditions. In the laboratory, uniformity of water application was calculated by the water emission uniformity coefficient (CUE), and the manufacturer's coefficient of variation (CVm). In addition, variation in the membrane diameter submitted to internal pressures; head losses along the membrane, using the energy equation; and, precision and accuracy of the equation model, analyzed by Pearson's correlation coefficient (r), and by Willmott's concordance index (d) were also calculated with samples of the developed emitters. In the field, the emitters were installed in pots with and without sugar cane culture from October 2010 to January 2012. During this time, flow rate in 20 emitters were measured periodically, and the aspects of them about clogging at the end of the experiment. Emitters flow rates were measured quarterly to calculate: relative flow rate (QR); flow disturbance (FD); CUE; and, variation coefficient of relative flow (CVQR). In the laboratory, both "CVm" and "CUE" were small since emitters were manufactured manually, the manufacturing variation was higher than in processed emitters. Variation in the membrane diameter decreased 1/4.5 from the central toward to the emitter end; and, the head loss increased. Estimated pressures were in good agreement to the observed ones with r and d values of 0.95, and 0.85, respectively. In the field tests, coefficients CVQR and QR were variable showing a poor classification according with ABNT (1986) and Solomon (1984). FD values were ranged between 11 and 24%and there was no observed clogging by roots and/or soil intrusion at the end of the experiment. On the other hand, emitter's flows were close to the average, indicating that water application kept according to the initial results. This study shows the suitability of this emitter model to prevent root and soil intrusion within the research conditions however further studies would be needed assessing the membrane performance, emitter physical characteristics, and control of emitter flow rate in order to develop the final prototype.

  13. Fault location in optical networks

    DOEpatents

    Stevens, Rick C [Apple Valley, MN; Kryzak, Charles J [Mendota Heights, MN; Keeler, Gordon A [Albuquerque, NM; Serkland, Darwin K [Albuquerque, NM; Geib, Kent M [Tijeras, NM; Kornrumpf, William P [Schenectady, NY

    2008-07-01

    One apparatus embodiment includes an optical emitter and a photodetector. At least a portion of the optical emitter extends a radial distance from a center point. The photodetector provided around at least a portion of the optical emitter and positioned outside the radial distance of the portion of the optical emitter.

  14. Individual neurophysiological profile in external effects investigation

    NASA Astrophysics Data System (ADS)

    Schastlivtseva, Daria; Tatiana Kotrovskaya, D..

    Cortex biopotentials are the significant elements in human psychophysiological individuality. Considered that cortical biopotentials are diverse and individually stable, therefore there is the existence of certain dependence between the basic properties of higher nervous activity and cerebral bioelectric activity. The main purpose of the study was to reveal the individual neurophysiological profile and CNS initial functional state manifestation in human electroencephalogram (EEG) under effect of inert gases (argon, xenon, helium), hypoxia, pressure changes (0.02 and 0.2 MPa). We obtained 5-minute eyes closed background EEG on 19 scalp positions using Ag/AgCl electrodes mounted in an electrode cap. All EEG signals were re-referenced to average earlobes; Fast Furies Transformation analysis was used to calculate the relative power spectrum of delta-, theta-, alpha- and beta frequency band in artifact-free EEG. The study involved 26 healthy men who provided written informed consent, aged 20 to 35 years. Data obtained depend as individual EEG type and initial central nervous functional state as intensity, duration and mix of factors. Pronounced alpha rhythm in the raw EEG correlated with their adaptive capacity under studied factor exposure. Representation change and zonal distribution perversion of EEG alpha rhythm were accompanied by emotional instability, increased anxiety and difficulty adapting subjects. High power factor or combination factor with psychological and emotional or physical exertion minimizes individual EEG pattern.

  15. Hybrid emitter all back contact solar cell

    DOEpatents

    Loscutoff, Paul; Rim, Seung

    2016-04-12

    An all back contact solar cell has a hybrid emitter design. The solar cell has a thin dielectric layer formed on a backside surface of a single crystalline silicon substrate. One emitter of the solar cell is made of doped polycrystalline silicon that is formed on the thin dielectric layer. The other emitter of the solar cell is formed in the single crystalline silicon substrate and is made of doped single crystalline silicon. The solar cell includes contact holes that allow metal contacts to connect to corresponding emitters.

  16. Optical phonon modes of III-V nanoparticles and indium phosphide/II-VI core-shell nanoparticles: A Raman and infrared study

    NASA Astrophysics Data System (ADS)

    Manciu, Felicia Speranta

    The prospects for realizing efficient nanoparticle light emitters in the visible/near IR for communications and bio-medical applications have benefited from progress in chemical fabrication of nanoparticles. III-V semiconductor nanopaticles such as GaP and InP are promising materials for the development of "blue" and "green" emitters, respectively, due to their large effective bandgaps. Enhanced emission efficiency has been achieved for core-shell nanoparticles, since inorganic shell materials increase electronic tunability and may decrease surface defects that often occur for nanoparticles capped with organic molecules. Also, the emission wavelength of InP nanoparticle cores can be tuned from green to red by changing the shell material in InP/II-VI core-shell nanoparticles. Investigations of phonon modes in nanocrystals are of both fundamental and applied interest. In the former case the optical phonon modes, such as surface/interface modes, are dependent on the nanoparticle dimensions, and also can provide information about dynamical properties of the nanoparticles and test the validity of various theoretical approaches. In the latter case the vibronic properties of nanoparticle emitters are controlled by confined phonons and modifications of the electron-phonon interaction by the confinement. Thus, the objective of the present thesis is the detailed study of the phonon modes of III-V nanoparticles (GaP and InP) and InP/II-VI core-shell nanoparticles by IR absorption and Raman scattering spectroscopies, and an elucidation of their complex vibrational properties. With the exception of three samples (two GaP and one InP), all samples were synthesized by a novel colloidal chemistry method, which does not requires added surfactant, but rather treatment of the corresponding precursors in octadecene noncoordinative solvent. Sample quality was characterized by ED, TEM and X-ray diffraction. Based on a comparison with a dielectric continuum model, the observed features in the IR and Raman results are assigned to the surface optical (SO) modes of the corresponding nanoparticles (InP and GaP), and to SO/interface modes for InP/II-VI core-shell nanoparticles. For the latter systems, an evaluation of the ratio of the shell material thickness to the core radius is achieved. Reasonable agreement is obtained between the Raman and FIR results, as well as with the calculations. (Abstract shortened by UMI.)

  17. Interaction of insulin with colloidal ZnS quantum dots functionalized by various surface capping agents.

    PubMed

    Hosseinzadeh, Ghader; Maghari, Ali; Farniya, Seyed Morteza Famil; Keihan, Amir Homayoun; Moosavi-Movahedi, Ali A

    2017-08-01

    Interaction of quantum dots (QDs) and proteins strongly influenced by the surface characteristics of the QDs at the protein-QD interface. For a precise control of these surface-related interactions, it is necessary to improve our understanding in this field. In this regard, in the present work, the interaction between the insulin and differently functionalized ZnS quantum dots (QDs) were studied. The ZnS QDs were functionalized with various functional groups of hydroxyl (OH), carboxyl (COOH), amine (NH 2 ), and amino acid (COOH and NH 2 ). The effect of surface hydrophobicity was also studied by changing the alkyl-chain lengths of mercaptocarboxylic acid capping agents. The interaction between insulin and the ZnS QDs were investigated by fluorescence quenching, synchronous fluorescence, circular dichroism (CD), and thermal aggregation techniques. The results reveal that among the studied QDs, mercaptosuccinic acid functionalized QDs has the strongest interaction (∆G ° =-51.50kJ/mol at 310K) with insulin, mercaptoethanol functionalized QDs destabilize insulin by increasing the beta-sheet contents, and only cysteine functionalized QDs improves the insulin stability by increasing the alpha-helix contents of the protein, and. Our results also indicate that by increasing the alkyl-chain length of capping agents, due to an increase in hydrophobicity of the QDs surface, the beta-sheet contents of insulin increase which results in the enhancement of insulin instability. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Venus 2004: east and west elongations and solar transit

    NASA Astrophysics Data System (ADS)

    McKim, R. J.; Blaxall, K.; Heath, A.

    2007-04-01

    The year 2004 was exceptional in producing the first solar transit of Venus since the late Victorian era. The bright aureole and atmospheric ring were re-observed, and the entire phenomenon was witnessed for the first time ever in hydrogen alpha light. Although routine observations throughout 2004 were unexceptional, patterns of visibility of bright and dark markings, cusp extensions and cusp-caps were recorded. No correlation was found between the latitude of the sub-Earth point and the visibility of either cusp-cap, with the S. cap predominating for most of the year. It was possible to accurately follow individual ultraviolet dark markings over many consecutive rotations, extending from the E. to W. elongations, and thereby to make a current measurement of the synodic atmospheric rotation period for the near-equatorial features: 3.996 ± 0.001 days. The true Ashen Light was reported visually on only a few occasions, but these correspond closely to times when infrared emission from the surface of the dark side was recorded in 1-micron waveband images. Some of the stable dark side albedo features were also visible upon the 1-micron images, and have been tentatively identified with known surface features. Infrared imaging at the same waveband showed little detail on the sunlit disk, but a few bright spots were sufficiently well observed to suggest a synodic rotation period close to 5.0 days, not atypical for the lower cloud decks.

  19. Ion Motion Induced Emittance Growth of Matched Electron Beams in Plasma Wakefields

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    An, Weiming; Lu, Wei; Huang, Chengkun

    2017-06-14

    Plasma-based acceleration is being considered as the basis for building a future linear collider. Nonlinear plasma wakefields have ideal properties for accelerating and focusing electron beams. Preservation of the emittance of nano-Coulomb beams with nanometer scale matched spot sizes in these wakefields remains a critical issue due to ion motion caused by their large space charge forces. We use fully resolved quasistatic particle-in-cell simulations of electron beams in hydrogen and lithium plasmas, including when the accelerated beam has different emittances in the two transverse planes. The projected emittance initially grows and rapidly saturates with a maximum emittance growth of lessmore » than 80% in hydrogen and 20% in lithium. The use of overfocused beams is found to dramatically reduce the emittance growth. In conclusion, the underlying physics that leads to the lower than expected emittance growth is elucidated.« less

  20. Emission Testing Results of Thermally Stable, Metamaterial, Selective-Emitters for Thermophotovoltaics

    NASA Astrophysics Data System (ADS)

    Levinson, Katherine; Naka, Norihito; Pfiester, Nicole; Licht, Abigail; Vandervelde, Tom

    2015-03-01

    In thermophotovoltaics, the energy from a heated emitter is converted to electricity by a photovoltaic diode. A selective emitter can be used to emit a narrow band of wavelengths tailored to the bandgap of the photovoltaic diode. This spectral shaping improves the conversion efficiency of the diode and reduces undesirable diode heating. In our research, we study selective emitters based on metamaterials composed of repeating nanoscale structures. The emission characteristics of these materials vary based on the compositional structure, allowing the emitted spectrum to be tunable. Simulations were performed with CST Microwave Studio to design emitters with peak wavelengths ranging from 1-10 microns. The structures were then fabricated using physical vapor deposition and electron beam lithography on a sapphire substrate. Emitter materials studied include gold, platinum, and iridium. Here we report on the emission spectra of the selective emitters and the post-heating structural integrity.

  1. Doping-free white organic light-emitting diodes without blue molecular emitter: An unexplored approach to achieve high performance via exciplex emission

    NASA Astrophysics Data System (ADS)

    Luo, Dongxiang; Xiao, Ye; Hao, Mingming; Zhao, Yu; Yang, Yibin; Gao, Yuan; Liu, Baiquan

    2017-02-01

    Doping-free white organic light-emitting diodes (DF-WOLEDs) are promising for the low-cost commercialization because of their simplified device structures. However, DF-WOLEDs reported thus far in the literature are based on the use of blue single molecular emitters, whose processing can represent a crucial point in device manufacture. Herein, DF-WOLEDs without the blue single molecular emitter have been demonstrated by managing a blue exciplex system. For the single-molecular-emitter (orange or yellow emitter) DF-WOLEDs, (i) a color rendering index (CRI) of 81 at 1000 cd/m2 can be obtained, which is one of the highest for the single-molecular-emitter WOLEDs, or (ii) a high efficiency of 35.4 lm/W can be yielded. For the dual-molecular-emitter (yellow/red emitters) DF-WOLED, a high CRI of 85 and low correlated color temperature of 2376 K at 1000 cd/m2 have been simultaneously achieved, which has not been reported by previous DF-WOLEDs. Such presented findings may unlock an alternative avenue to the simplified but high-performance WOLEDs.

  2. Single photon emission from plasma treated 2D hexagonal boron nitride.

    PubMed

    Xu, Zai-Quan; Elbadawi, Christopher; Tran, Toan Trong; Kianinia, Mehran; Li, Xiuling; Liu, Daobin; Hoffman, Timothy B; Nguyen, Minh; Kim, Sejeong; Edgar, James H; Wu, Xiaojun; Song, Li; Ali, Sajid; Ford, Mike; Toth, Milos; Aharonovich, Igor

    2018-05-03

    Artificial atomic systems in solids are becoming increasingly important building blocks in quantum information processing and scalable quantum nanophotonic networks. Amongst numerous candidates, 2D hexagonal boron nitride has recently emerged as a promising platform hosting single photon emitters. Here, we report a number of robust plasma and thermal annealing methods for fabrication of emitters in tape-exfoliated hexagonal boron nitride (hBN) crystals. A two-step process comprising Ar plasma etching and subsequent annealing in Ar is highly robust, and yields an eight-fold increase in the concentration of emitters in hBN. The initial plasma-etching step generates emitters that suffer from blinking and bleaching, whereas the two-step process yields emitters that are photostable at room temperature with emission wavelengths greater than ∼700 nm. Density functional theory modeling suggests that the emitters might be associated with defect complexes that contain oxygen. This is further confirmed by generating the emitters via annealing hBN in air. Our findings advance the present understanding of the structure of quantum emitters in hBN and enhance the nanofabrication toolkit needed to realize integrated quantum nanophotonic circuits.

  3. Thermal emittance enhancement of graphite-copper composites for high temperature space based radiators

    NASA Technical Reports Server (NTRS)

    Rutledge, Sharon K.; Forkapa, Mark J.; Cooper, Jill M.

    1991-01-01

    Graphite-copper composites are candidate materials for space based radiators. The thermal emittance of this material, however, is a factor of two lower than the desired emittance for these systems of greater than or equal to 0.85. Arc texturing was investigated as a surface modification technique for enhancing the emittance of the composite. Since the outer surface of the composite is copper, and samples of the composite could not be readily obtained for testing, copper was used for optimization testing. Samples were exposed to various frequencies and currents of arcs during texturing. Emittances near the desired goal were achieved at frequencies less than 500 Hz. Arc current did not appear to play a major role under 15 amps. Particulate carbon was observed on the surface, and was easily removed by vibration and handling. In order to determine morphology adherence, ultrasonic cleaning was used to remove the loosely adherent material. This reduced the emittance significantly. Emittance was found to increase with increasing frequency for the cleaned samples up to 500 Hz. The highest emittance achieved on these samples over the temperature range of interest was 0.5 to 0.6, which is approximately a factor of 25 increase over the untextured copper emittance.

  4. Chemically doped three-dimensional porous graphene monoliths for high-performance flexible field emitters.

    PubMed

    Kim, Ho Young; Jeong, Sooyeon; Jeong, Seung Yol; Baeg, Kang-Jun; Han, Joong Tark; Jeong, Mun Seok; Lee, Geon-Woong; Jeong, Hee Jin

    2015-03-12

    Despite the recent progress in the fabrication of field emitters based on graphene nanosheets, their morphological and electrical properties, which affect their degree of field enhancement as well as the electron tunnelling barrier height, should be controlled to allow for better field-emission properties. Here we report a method that allows the synthesis of graphene-based emitters with a high field-enhancement factor and a low work function. The method involves forming monolithic three-dimensional (3D) graphene structures by freeze-drying of a highly concentrated graphene paste and subsequent work-function engineering by chemical doping. Graphene structures with vertically aligned edges were successfully fabricated by the freeze-drying process. Furthermore, their number density could be controlled by varying the composition of the graphene paste. Al- and Au-doped 3D graphene emitters were fabricated by introducing the corresponding dopant solutions into the graphene sheets. The resulting field-emission characteristics of the resulting emitters are discussed. The synthesized 3D graphene emitters were highly flexible, maintaining their field-emission properties even when bent at large angles. This is attributed to the high crystallinity and emitter density and good chemical stability of the 3D graphene emitters, as well as to the strong interactions between the 3D graphene emitters and the substrate.

  5. Construction and measurements of a vacuum-swing-adsorption radon-mitigation system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schnee, R. W.; Bunker, R.; Ghulam, G.

    Long-lived alpha and beta emitters in the {sup 222}Rn decay chain on (and near) detector surfaces may be the limiting background in many experiments attempting to detect dark matter or neutrinoless double beta decay, and in screening detectors. In order to reduce backgrounds from radon-daughter plate-out onto the wires of the Beta Cage during its assembly, an ultra-low-radon cleanroom is being commissioned at Syracuse University using a vacuum-swing-adsorption radon-mitigation system. The radon filter shows ∼20× reduction at its output, from 7.47±0.56 to 0.37±0.12 Bq/m{sup 3}, and the cleanroom radon activity meets project requirements, with a lowest achieved value consistent withmore » that of the filter, and levels consistently < 2 Bq/m{sup 3}.« less

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adelstein, S.J.; Kassis, A.I.

    This report describes many factors that need to be considered if radioimmunotherapy is to become a commonplace reality. For beta-emitting radionuclides, two physical features of importance are half-life and energy, with the latter determining the range. These features must be matched to the pharmacokinetics of the carrier and the distribution of the radionuclide, both macroscopically and microscopically. Alpha-particle emitters could be considered for cells that are readily accessible to the labeled antibody and for populations that uniformly and constantly display the targeted antigen or idiotype, e.g., trafficking cells such as T or B lymphocytes. For cells that concentrate the radioactivemore » label, the use of low-energy electrons should be examined. If the radionuclide is translocated to the nucleus, the Auger effect can be particularly lethal because of the high LET-like biological response. 15 refs., 3 figs., 2 tabs.« less

  7. Determination of Low Level Alpha and Beta Emitters Using Liquid-Liquid Extraction and a Liquid Scintillation Spectrometer

    NASA Astrophysics Data System (ADS)

    Yu, Yu-Fu; BjØRnstad, H. E.; Salbu, B.

    Two radiochemical procedures for determination of low level strontium-90 and plutonium-239+240 in environmental and biological materials using combined selective solvent extraction with low level liquid scintillation counting have been presented. Y-90, the daughter nuclide of Sr-90, and Pu-239+240 are selectively extracted from nitric acid solution into 5% di(-2ethylhexyl)phosphoric acid (HDEHP) in toluene and the radionuclides of interest in organic phase are counted with an ultra low level scintillation counter "Quantulus". The lower detection limits for Sr-90 and Pu-239+240 are estimated to be 20 mBq and 0.3 mBq respectively. The developed procedures have been tested for soma environmental and biological samples and the preminarly results show that they are more simple and time-saving than traditional methods.

  8. Do Lyman-alpha photons escape from star-forming galaxies through dust-holes?

    NASA Astrophysics Data System (ADS)

    Wofford, Aida

    2012-10-01

    The hydrogen Lyman-alpha line is arguably the most important signature of galaxies undergoing their first violent burst of star formation. Although Lya photons are easily destroyed by dust, candidate Lya emitters have been detected at z>5. Thus the line can potentially be used to probe galaxy formation and evolution, as long as the astrophysical processes that regulate the escape of Lya photons from star-forming galaxies are well understood.We request 15 orbits for imaging in Lya and the FUV continuum with ACS/SBC, and in the H-beta/H-alpha ratio {proxy for dust extinction} with WFC3/UVIS, a sample of isolated non-AGN face-on spirals for which our team previously obtained and analyzed COS FUV spectroscopy of the central regions. Each target shows a different Lya profile, i.e., pure absorption, P-Cygni like, and multiple-emission. From the COS data, we already know the starburst phase and H I gas velocity. The images would greatly increase the impact of our spectroscopic study by enabling us to 1} conclusively determine if Lya photons escape through dust-holes, 2} assess the relative importance of dust extinction, ISM kinematics, and starburst phase in regulating the Lya escape, 3} clarify what we can really learn from the Lya equivalent width, and 4} provide constraints on the dust extinction to Lya 3D radiative transfer models. Ultimately this program will inform our understanding of the Lya escape at high redshift by providing spatially resolved views of the local conditions within star-forming galaxies that favor escape.

  9. Superresolution microscope image reconstruction by spatiotemporal object decomposition and association: application in resolving t-tubule structure in skeletal muscle

    PubMed Central

    Sun, Mingzhai; Huang, Jiaqing; Bunyak, Filiz; Gumpper, Kristyn; De, Gejing; Sermersheim, Matthew; Liu, George; Lin, Pei-Hui; Palaniappan, Kannappan; Ma, Jianjie

    2014-01-01

    One key factor that limits resolution of single-molecule superresolution microscopy relates to the localization accuracy of the activated emitters, which is usually deteriorated by two factors. One originates from the background noise due to out-of-focus signals, sample auto-fluorescence, and camera acquisition noise; and the other is due to the low photon count of emitters at a single frame. With fast acquisition rate, the activated emitters can last multiple frames before they transiently switch off or permanently bleach. Effectively incorporating the temporal information of these emitters is critical to improve the spatial resolution. However, majority of the existing reconstruction algorithms locate the emitters frame by frame, discarding or underusing the temporal information. Here we present a new image reconstruction algorithm based on tracklets, short trajectories of the same objects. We improve the localization accuracy by associating the same emitters from multiple frames to form tracklets and by aggregating signals to enhance the signal to noise ratio. We also introduce a weighted mean-shift algorithm (WMS) to automatically detect the number of modes (emitters) in overlapping regions of tracklets so that not only well-separated single emitters but also individual emitters within multi-emitter groups can be identified and tracked. In combination with a maximum likelihood estimator method (MLE), we are able to resolve low to medium density of overlapping emitters with improved localization accuracy. We evaluate the performance of our method with both synthetic and experimental data, and show that the tracklet-based reconstruction is superior in localization accuracy, particularly for weak signals embedded in a strong background. Using this method, for the first time, we resolve the transverse tubule structure of the mammalian skeletal muscle. PMID:24921337

  10. Theory and measurements of emittance preservation in plasma wakefield acceleration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frederico, Joel

    2016-12-01

    In this dissertation, we examine the preservation and measurement of emittance in the plasma wakefield acceleration blowout regime. Plasma wakefield acceleration (PWFA) is a revolutionary approach to accelerating charged particles that has been demonstrated to have the potential for gradients orders of magnitude greater than traditional approaches. The application of PWFA to the design of a linear collider will make new high energy physics research possible, but the design parameters must first be shown to be competitive with traditional methods. Emittance preservation is necessary in the design of a linear collider in order to maximize luminosity. We examine the conditionsmore » necessary for circular symmetry in the PWFA blowout regime, and demonstrate that current proposals meet these bounds. We also present an application of beam lamentation which describes the process of beam parameter and emittance matching. We show that the emittance growth saturates as a consequence of energy spread in the beam. The initial beam parameters determine the amount of emittance growth, while the contribution of energy spread is negligible. We also present a model for ion motion in the presence of a beam that is much more dense than the plasma. By combining the model of ion motion and emittance growth, we find the emittance growth due to ion motion is minimal in the case of marginal ion motion. In addition, we present a simulation that validates the ion motion model, which is under further development to examine emittance growth of both marginal and pronounced ion motion. Finally, we present a proof-of-concept of an emittance measurement which may enable the analysis of emittance preservation in future PWFA experiments.« less

  11. Superresolution microscope image reconstruction by spatiotemporal object decomposition and association: application in resolving t-tubule structure in skeletal muscle.

    PubMed

    Sun, Mingzhai; Huang, Jiaqing; Bunyak, Filiz; Gumpper, Kristyn; De, Gejing; Sermersheim, Matthew; Liu, George; Lin, Pei-Hui; Palaniappan, Kannappan; Ma, Jianjie

    2014-05-19

    One key factor that limits resolution of single-molecule superresolution microscopy relates to the localization accuracy of the activated emitters, which is usually deteriorated by two factors. One originates from the background noise due to out-of-focus signals, sample auto-fluorescence, and camera acquisition noise; and the other is due to the low photon count of emitters at a single frame. With fast acquisition rate, the activated emitters can last multiple frames before they transiently switch off or permanently bleach. Effectively incorporating the temporal information of these emitters is critical to improve the spatial resolution. However, majority of the existing reconstruction algorithms locate the emitters frame by frame, discarding or underusing the temporal information. Here we present a new image reconstruction algorithm based on tracklets, short trajectories of the same objects. We improve the localization accuracy by associating the same emitters from multiple frames to form tracklets and by aggregating signals to enhance the signal to noise ratio. We also introduce a weighted mean-shift algorithm (WMS) to automatically detect the number of modes (emitters) in overlapping regions of tracklets so that not only well-separated single emitters but also individual emitters within multi-emitter groups can be identified and tracked. In combination with a maximum likelihood estimator method (MLE), we are able to resolve low to medium density of overlapping emitters with improved localization accuracy. We evaluate the performance of our method with both synthetic and experimental data, and show that the tracklet-based reconstruction is superior in localization accuracy, particularly for weak signals embedded in a strong background. Using this method, for the first time, we resolve the transverse tubule structure of the mammalian skeletal muscle.

  12. Long-lived and highly efficient green and blue phosphorescent emitters and device architectures for OLED displays

    NASA Astrophysics Data System (ADS)

    Eickhoff, Christian; Murer, Peter; Geßner, Thomas; Birnstock, Jan; Kröger, Michael; Choi, Zungsun; Watanabe, Soichi; May, Falk; Lennartz, Christian; Stengel, Ilona; Münster, Ingo; Kahle, Klaus; Wagenblast, Gerhard; Mangold, Hannah

    2015-09-01

    In this paper, two OLED device concepts are introduced. First, classical phosphorescent green carbene emitters with unsurpassed lifetime, combined with low voltage and high efficiency are presented and the associated optimized OLED stacks are explained. Second, a path towards highly efficient, long-lived deep blue systems is shown. The high efficiencies can be reached by having the charge-recombination on the phosphorescent carbene emitter while at the same time short emissive lifetimes are realized by fast energy transfer to the fluorescent emitter, which eventually allows for higher OLED stability in the deep blue. Device architectures, materials and performance data are presented showing that carbene type emitters have the potential to outperform established phosphorescent green emitters both in terms of lifetime and efficiency. The specific class of green emitters under investigation shows distinctly larger electron affinities (2.1 to 2.5 eV) and ionization potentials (5.6 to 5.8 eV) as compared to the "standard" emitter Ir(ppy)3 (5.0/1.6 eV). This difference in energy levels requires an adopted OLED design, in particular with respect to emitter hosts and blocking layers. Consequently, in the diode setup presented here, the emitter species is electron transporting or electron trapping. For said green carbene emitters, the typical peak wavelength is 525 nm yielding CIE color coordinates of (x = 0.33, y = 0.62). Device data of green OLEDs are shown with EQEs of 26 %. Driving voltage at 1000 cd/m2 is below 3 V. In an optimized stack, a device lifetime of LT95 > 15,000 h (1000 cd/m2) has been reached, thus fulfilling AMOLED display requirements.

  13. Lyman-α emitters gone missing: the different evolution of the bright and faint populations

    NASA Astrophysics Data System (ADS)

    Weinberger, Lewis H.; Kulkarni, Girish; Haehnelt, Martin G.; Choudhury, Tirthankar Roy

    2018-06-01

    We model the transmission of the Lyman-α line through the circum- and intergalactic media around dark matter haloes expected to host Lyman-alpha emitters (LAEs) at z ≥ 5.7, using the high-dynamic-range Sherwood simulations. We find very different CGM environments around more massive haloes (˜1011M⊙) compared to less massive haloes (˜109M⊙) at these redshifts, which can contribute to a different evolution of the Lyα transmission from LAEs within these haloes. Additionally we confirm that part of the differential evolution could result from bright LAEs being more likely to reside in larger ionized regions. We conclude that a combination of the CGM environment and the IGM ionization structure is likely to be responsible for the differential evolution of the bright and faint ends of the LAE luminosity function at z ≥ 6. More generally, we confirm the suggestion that the self-shielded neutral gas in the outskirts of the host halo can strongly attenuate the Lyα emission from high redshift galaxies. We find that this has a stronger effect on the more massive haloes hosting brighter LAEs. The faint-end of the LAE luminosity function is thus a more reliable probe of the average ionization state of the IGM. Comparing our model for LAEs with a range of observational data we find that the favoured reionization histories are our previously advocated `Late' and `Very Late' reionization histories, in which reionization finishes rather rapidly at around z ≃ 6.

  14. Chromate conversion coating: Iridite 14-2 thermal/optical characterization

    NASA Astrophysics Data System (ADS)

    Rodriguez, Marcello

    2012-10-01

    Chromate Conversion Coating (CCC) BOL and EOL thermal properties (absorptance and emittance) have been unspecified throughout the industry and throughout its use here at GSFC. Being key values essential for thermal engineers to assess thermal space conditions, this study focuses on the current application process, its outputted properties and assess whether these properties can in turn be classified under proper documentation. The results show that wide variations in the process overcome any possibility in thermally classifying this coating. A new set of samples were fabricated (in preparation for space environmental studies) in which a more controlled approach to applying the CCC was made. The resulting thermal values continued to show variations indicating lack of bath agitation existing within the bath. From this study you can conclude that witness samples may not best represent the flight hardware for this coating. The study then turns to space environmental study testing samples to high temperature (80°C), high vacuum, and combination of both, and UV radiation totaling 1625 ESH. The results showed an extremely dynamic coating sensitive to every environmental condition it was exposed to. Though the initial changes to the coating are drastic, post initial changes appear to be minuscule making EOL predictions more attainable. These results show that the worst case alpha/emittance values are likely after ground processing and before space exposure. From the data obtained in this study greater understanding and more informed decisions can be made with respect to this coating.

  15. Prediction and design of efficient exciplex emitters for high-efficiency, thermally activated delayed-fluorescence organic light-emitting diodes.

    PubMed

    Liu, Xiao-Ke; Chen, Zhan; Zheng, Cai-Jun; Liu, Chuan-Lin; Lee, Chun-Sing; Li, Fan; Ou, Xue-Mei; Zhang, Xiao-Hong

    2015-04-08

    High-efficiency, thermally activated delayed-fluorescence organic light-emitting diodes based on exciplex emitters are demonstrated. The best device, based on a TAPC:DPTPCz emitter, shows a high external quantum efficiency of 15.4%. Strategies for predicting and designing efficient exciplex emitters are also provided. This approach allow prediction and design of efficient exciplex emitters for achieving high-efficiency organic light-emitting diodes, for future use in displays and lighting applications. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Thermionic gas switch

    DOEpatents

    Hatch, George L.; Brummond, William A.; Barrus, Donald M.

    1986-01-01

    A temperature responsive thermionic gas switch having folded electron emitting surfaces. An ionizable gas is located between the emitter and an interior surface of a collector, coaxial with the emitter. In response to the temperature exceeding a predetermined level, sufficient electrons are derived from the emitter to cause the gas in the gap between the emitter and collector to become ionized, whereby a very large increase in current in the gap occurs. Due to the folded emitter surface area of the switch, increasing the "on/off" current ratio and adjusting the "on" current capacity is accomplished.

  17. Minimum emittance in TBA and MBA lattices

    NASA Astrophysics Data System (ADS)

    Xu, Gang; Peng, Yue-Mei

    2015-03-01

    For reaching a small emittance in a modern light source, triple bend achromats (TBA), theoretical minimum emittance (TME) and even multiple bend achromats (MBA) have been considered. This paper derived the necessary condition for achieving minimum emittance in TBA and MBA theoretically, where the bending angle of inner dipoles has a factor of 31/3 bigger than that of the outer dipoles. Here, we also calculated the conditions attaining the minimum emittance of TBA related to phase advance in some special cases with a pure mathematics method. These results may give some directions on lattice design.

  18. Simulated Performance of the Wisconsin Superconducting Electron Gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    R.A. Bosch, K.J. Kleman, R.A. Legg

    2012-07-01

    The Wisconsin superconducting electron gun is modeled with multiparticle tracking simulations using the ASTRA and GPT codes. To specify the construction of the emittance-compensation solenoid, we studied the dependence of the output bunch's emittance upon the solenoid's strength and field errors. We also evaluated the dependence of the output bunch's emittance upon the bunch's initial emittance and the size of the laser spot on the photocathode. The results suggest that a 200-pC bunch with an emittance of about one mm-mrad can be produced for a free-electron laser.

  19. Solar absorptance and thermal emittance of some common spacecraft thermal-control coatings

    NASA Technical Reports Server (NTRS)

    Henninger, J. H.

    1984-01-01

    Solar absorptance and thermal emittance of spacecraft materials are critical parameters in determining spacecraft temperature control. Because thickness, surface preparation, coatings formulation, manufacturing techniques, etc. affect these parameters, it is usually necessary to measure the absorptance and emittance of materials before they are used. Absorptance and emittance data for many common types of thermal control coatings, are together with some sample spectral data curves of absorptance. In some cases for which ultraviolet and particle radiation data are available, the degraded absorptance and emittance values are also listed.

  20. High-Performance Field Emission from a Carbonized Cork.

    PubMed

    Lee, Jeong Seok; Lee, Hak Jun; Yoo, Jae Man; Kim, Taewoo; Kim, Yong Hyup

    2017-12-20

    To broaden the range of application of electron beams, low-power field emitters are needed that are miniature and light. Here, we introduce carbonized cork as a material for field emitters. The light natural cork becomes a graphitic honeycomb upon carbonization, with the honeycomb cell walls 100-200 nm thick and the aspect ratio larger than 100, providing an ideal structure for the field electron emission. Compared to nanocarbon field emitters, the cork emitter produces a high current density and long-term stability with a low turn-on field. The nature of the cork material makes it quite simple to fabricate the emitter. Furthermore, any desired shape of the emitter tailored for the final application can easily be prepared for point, line, or planar emission.

Top