Sample records for capabilities traceability flow

  1. Visualizing and Validating Metadata Traceability within the CDISC Standards.

    PubMed

    Hume, Sam; Sarnikar, Surendra; Becnel, Lauren; Bennett, Dorine

    2017-01-01

    The Food & Drug Administration has begun requiring that electronic submissions of regulated clinical studies utilize the Clinical Data Information Standards Consortium data standards. Within regulated clinical research, traceability is a requirement and indicates that the analysis results can be traced back to the original source data. Current solutions for clinical research data traceability are limited in terms of querying, validation and visualization capabilities. This paper describes (1) the development of metadata models to support computable traceability and traceability visualizations that are compatible with industry data standards for the regulated clinical research domain, (2) adaptation of graph traversal algorithms to make them capable of identifying traceability gaps and validating traceability across the clinical research data lifecycle, and (3) development of a traceability query capability for retrieval and visualization of traceability information.

  2. Visualizing and Validating Metadata Traceability within the CDISC Standards

    PubMed Central

    Hume, Sam; Sarnikar, Surendra; Becnel, Lauren; Bennett, Dorine

    2017-01-01

    The Food & Drug Administration has begun requiring that electronic submissions of regulated clinical studies utilize the Clinical Data Information Standards Consortium data standards. Within regulated clinical research, traceability is a requirement and indicates that the analysis results can be traced back to the original source data. Current solutions for clinical research data traceability are limited in terms of querying, validation and visualization capabilities. This paper describes (1) the development of metadata models to support computable traceability and traceability visualizations that are compatible with industry data standards for the regulated clinical research domain, (2) adaptation of graph traversal algorithms to make them capable of identifying traceability gaps and validating traceability across the clinical research data lifecycle, and (3) development of a traceability query capability for retrieval and visualization of traceability information. PMID:28815125

  3. Uncertainty and Traceability for the CEESI Iowa Natural Gas Facility.

    PubMed

    Johnson, Aaron; Kegel, Tom

    2004-01-01

    This paper analyzes the uncertainty of a secondary flow measurement facility that calibrates a significant fraction of United States and foreign flow meters used for custody transfer of natural gas. The facility, owned by the Colorado Experimental Engineering Station Incorporated (CEESI), is located in Iowa. This facility measures flow with nine turbine meter standards, each of which is traceable to the NIST primary flow standard. The flow capacity of this facility ranges from 0.7 actual m(3)/s to 10.7 actual m(3)/s at nominal pressures of 7174 kPa and at ambient temperatures. Over this flow range the relative expanded flow uncertainty varies from 0.28 % to 0.30 % (depending on flow).

  4. Towards automated traceability maintenance

    PubMed Central

    Mäder, Patrick; Gotel, Orlena

    2012-01-01

    Traceability relations support stakeholders in understanding the dependencies between artifacts created during the development of a software system and thus enable many development-related tasks. To ensure that the anticipated benefits of these tasks can be realized, it is necessary to have an up-to-date set of traceability relations between the established artifacts. This goal requires the creation of traceability relations during the initial development process. Furthermore, the goal also requires the maintenance of traceability relations over time as the software system evolves in order to prevent their decay. In this paper, an approach is discussed that supports the (semi-) automated update of traceability relations between requirements, analysis and design models of software systems expressed in the UML. This is made possible by analyzing change events that have been captured while working within a third-party UML modeling tool. Within the captured flow of events, development activities comprised of several events are recognized. These are matched with predefined rules that direct the update of impacted traceability relations. The overall approach is supported by a prototype tool and empirical results on the effectiveness of tool-supported traceability maintenance are provided. PMID:23471308

  5. Study on Full Supply Chain Quality and Safetytraceability Systems For Cereal And Oilproducts

    NASA Astrophysics Data System (ADS)

    Liu, Shihong; Zheng, Huoguo; Meng, Hong; Hu, Haiyan; Wu, Jiangshou; Li, Chunhua

    Global food industry and Governments in many countries are putting increasing emphasis on establishment of food traceability systems. Food traceability has become an effective way in food safety management. Aimed at the major quality problems of cereal and oil products existing in the production, processing, warehousing, distribution and other links in the supply chain, this paper firstly proposes a new traceability framework combines the information flow with critical control points and quality indicators. Then it introduces traceability database design and data access mode to realize the framework. In practice, Code design for tracing goods is a challenge thing, so this paper put forward a code system based on UCC/EAN-128 standard.Middleware and Electronic terminal design are also briefly introduced to accomplish traceability system for cereal and oil products.

  6. Modeling traceability information and functionality requirement in export-oriented tilapia chain.

    PubMed

    Zhang, Xiaoshuan; Feng, Jianying; Xu, Mark; Hu, Jinyou

    2011-05-01

    Tilapia has been named as the 'food fish of the 21st century' and has become the most important farmed fish. China is the world leader in tilapia production and export. Identifying information and functional requirements is critical in developing an efficient traceability system because traceability has become a fundamental prerequisite for exporting aquaculture products. This paper examines the export-oriented tilapia chains and information flow in the chains, and identifies the key actors, information requirements and information-capturing points. Unified Modeling Language (UML) technology is adopted to describe the information and functionality requirement for chain traceability. The barriers of traceability system adoption are also identified. The results show that the traceability data consist of four categories that must be recorded by each link in the chain. The functionality requirement is classified into four categories from the fundamental information record to decisive quality control; the top three barriers to the traceability system adoption are: high costs of implementing the system, lack of experienced and professional staff; and low level of government involvement and support. Copyright © 2011 Society of Chemical Industry.

  7. Metrological AFMs and its application for versatile nano-dimensional metrology tasks

    NASA Astrophysics Data System (ADS)

    Dai, Gaoliang; Dziomba, T.; Pohlenz, F.; Danzebrink, H.-U.; Koenders, L.

    2010-08-01

    Traceable calibrations of various micro and nano measurement devices are crucial tasks for ensuring reliable measurements for micro and nanotechnology. Today metrological AFM are widely used for traceable calibrations of nano dimensional standards. In this paper, we introduced the developments of metrological force microscopes at PTB. Of the three metrological AFMs described here, one is capable of measuring in a volume of 25 mm x 25 mm x 5 mm. All instruments feature interferometers and the three-dimensional position measurements are thus directly traceable to the metre definition. Some calibration examples on, for instance, flatness standards, step height standards, one and two dimensional gratings are demonstrated.

  8. An aspect-oriented approach for designing safety-critical systems

    NASA Astrophysics Data System (ADS)

    Petrov, Z.; Zaykov, P. G.; Cardoso, J. P.; Coutinho, J. G. F.; Diniz, P. C.; Luk, W.

    The development of avionics systems is typically a tedious and cumbersome process. In addition to the required functions, developers must consider various and often conflicting non-functional requirements such as safety, performance, and energy efficiency. Certainly, an integrated approach with a seamless design flow that is capable of requirements modelling and supporting refinement down to an actual implementation in a traceable way, may lead to a significant acceleration of development cycles. This paper presents an aspect-oriented approach supported by a tool chain that deals with functional and non-functional requirements in an integrated manner. It also discusses how the approach can be applied to development of safety-critical systems and provides experimental results.

  9. Traceability from a US perspective.

    PubMed

    Smith, G C; Tatum, J D; Belk, K E; Scanga, J A; Grandin, T; Sofos, J N

    2005-09-01

    Traceability of a food consists of development of "an information trail that follows the food product's physical trail". Internationally, the US is lagging behind many countries in developing traceability systems for food in general and especially for livestock, poultry and their products. The US food industry is developing, implementing and maintaining traceability systems designed to improve food supply management, facilitate traceback for food safety and quality, and differentiate and market foods with subtle or undetectable quality attributes. Traceability, for livestock, poultry and meat, in its broadest context, can, could, or will eventually be used: (1) to ascertain origin and ownership, and to deter theft and misrepresentation, of animals and meat; (2) for surveillance, control and eradication of foreign animal diseases; (3) for biosecurity protection of the national livestock population; (4) for compliance with requirements of international customers; (5) for compliance with country-of-origin labeling requirements; (6) for improvement of supply-side management, distribution/delivery systems and inventory controls; (7) to facilitate value-based marketing; (8) to facilitate value-added marketing; (9) to isolate the source and extent of quality-control and food-safety problems; and (10) to minimize product recalls and make crisis management protocols more effective. Domestically and internationally, it has now become essential that producers, packers, processors, wholesalers, exporters and retailers assure that livestock, poultry and meat are identified, that record-keeping assures traceability through all or parts of the complete life-cycle, and that, in some cases, the source, the production-practices and/or the process of generating final products, can be verified. At issue, as the US develops traceback capabilities, will be the breadth, depth and precision of its specific traceability systems.

  10. Development of the management for parenteral nutrition traceability in a standard hospital.

    PubMed

    Bernabeu Soria, Beatriz; Mateo García, Máxima; Wanden-Berghe, Carmina; Cervera Peris, Mercedes; Piñeiro Corrales, Guadalupe; Sanz-Valero, Javier

    2015-11-01

    to develop the traceability control and the hazard analysis in the processes of parenteral nutrients (PN). a standardized graphical notation was generated, describing in detail each of the stages in the overall process. The presence of hazards was analysed by sequencing decisions. The existence of Control Points (CP) or Critical Control Points (CCP) was estimated by Criticality Index (CI) for each hazard taking into account the probability of occurrence and the severity of the damage. The threshold for the IC was set in 6. a specific flow chart for the management and traceability of PN was obtained, defining each of the stages in CPs (validation and transcription of the prescription and administration) or CCPs (preparation, storage and infusion pump -flow and filter-). Stages regarding the delivery, the recovery and the recycle of the packing material of PNs are not considered CPs and, therefore, they were not included in the dashboard. PN must be dealt with in the frame of a standardized management system in order to improve patient safety, clinical relevance, maximize resource efficiency and minimize procedural issues. The proposed system provides a global management model whose steps are fully defined, allowing monitoring and verification of PN. It would be convenient to make use of a software application to support the monitoring of the traceability management and to store the historical records in order to evaluate the system. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  11. Statistical evaluation of PACSTAT random number generation capabilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Piepel, G.F.; Toland, M.R.; Harty, H.

    1988-05-01

    This report summarizes the work performed in verifying the general purpose Monte Carlo driver-program PACSTAT. The main objective of the work was to verify the performance of PACSTAT's random number generation capabilities. Secondary objectives were to document (using controlled configuration management procedures) changes made in PACSTAT at Pacific Northwest Laboratory, and to assure that PACSTAT input and output files satisfy quality assurance traceability constraints. Upon receipt of the PRIME version of the PACSTAT code from the Basalt Waste Isolation Project, Pacific Northwest Laboratory staff converted the code to run on Digital Equipment Corporation (DEC) VAXs. The modifications to PACSTAT weremore » implemented using the WITNESS configuration management system, with the modifications themselves intended to make the code as portable as possible. Certain modifications were made to make the PACSTAT input and output files conform to quality assurance traceability constraints. 10 refs., 17 figs., 6 tabs.« less

  12. Thermal Protection Test Bed Pathfinder Development Project

    NASA Technical Reports Server (NTRS)

    Snapp, Cooper

    2015-01-01

    In order to increase thermal protection capabilities for future reentry vehicles, a method to obtain relevant test data is required. Although arc jet testing can be used to obtain some data on materials, the best method to obtain these data is to actually expose them to an atmospheric reentry. The overprediction of the Orion EFT-1 flight data is an example of how the ground test to flight traceability is not fully understood. The RED-Data small reentry capsule developed by Terminal Velocity Aerospace is critical to understanding this traceability. In order to begin to utilize this technology, ES3 needs to be ready to build and integrate heat shields onto the RED-Data vehicle. Using a heritage Shuttle tile material for the heat shield will both allow valuable insight into the environment that the RED-Data vehicle can provide and give ES3 the knowledge and capability to build and integrate future heat shields for this vehicle.

  13. The role of psychological determinants and demographic factors in consumer demand for farm-to-fork traceability systems.

    PubMed

    Myae, Aye Chan; Goddard, Ellen; Aubeeluck, Ashwina

    2011-01-01

    Traceability systems are an important tool (1) for tracking, monitoring, and managing product flows through the supply chain for better efficiency and profitability of suppliers, and (2) to improve consumer confidence in the face of serious food safety incidents. After the global bovine spongiform encephalopathy (BSE) crisis affected producers, consumers, trade, and the health status of animals and humans, new systems to help confirm the status of cattle products along the supply chain from farm to fork were implemented in many countries (Trautman et al. 2008 ). In this study, people's overall food safety beliefs are explored with the main objective of measuring the link between their food safety beliefs and their attitudes toward traceability. A comparison is made among English-speaking Canadians, French-speaking Canadians, and Japanese consumers. In the study, an Internet-based survey was used to collect data from nationally representative samples of the population in Canada-English (1275), Canada-French (343), and Japanese (1940) in the summer of 2009. Respondents' interests in traceability systems are clearly linked to their sense that the industry is primarily responsible for any food safety outbreaks. Moreover, it is clear that certain segments of the population in all samples feel strongly about the importance of farm to fork traceability in beef; thus, policymakers may wish to consider extending traceability beyond the point of slaughter as a way of encouraging beef sales in Canada.

  14. Framework for Design of Traceability System on Organic Rice Certification

    NASA Astrophysics Data System (ADS)

    Purwandoko, P. B.; Seminar, K. B.; Sutrisno; Sugiyanta

    2018-05-01

    Nowadays, the preferences of organic products such as organic rice have been increased. It because of the people awareness of the healthy and eco-friendly food product consumption has grown. Therefore, it is very important to ensure organic quality of the product that will be produced. Certification is a series of process that holds to ensure the quality of products meets all criteria of organic standards. Currently, there is a problem that traceability information system for organic rice certification has been not available. The current system still conducts manually caused the loss of information during storage process. This paper aimed at developing a traceability framework on organic rice certification process. First, the main discussed issues are organic certification process. Second, unified modeling language (UML) is used to build the model of user requirement in order to develop traceability system for all actors in the certification process. Furthermore, the information captured model along certification process will be explained in this paper. The model shows the information flow that has to be recorded for each actor. Finally, the challenges in the implementation system will be discussed in this paper.

  15. Primary standards for measuring flow rates from 100 nl/min to 1 ml/min - gravimetric principle.

    PubMed

    Bissig, Hugo; Petter, Harm Tido; Lucas, Peter; Batista, Elsa; Filipe, Eduarda; Almeida, Nelson; Ribeiro, Luis Filipe; Gala, João; Martins, Rui; Savanier, Benoit; Ogheard, Florestan; Niemann, Anders Koustrup; Lötters, Joost; Sparreboom, Wouter

    2015-08-01

    Microflow and nanoflow rate calibrations are important in several applications such as liquid chromatography, (scaled-down) process technology, and special health-care applications. However, traceability in the microflow and nanoflow range does not go below 16 μl/min in Europe. Furthermore, the European metrology organization EURAMET did not yet validate this traceability by means of an intercomparison between different National Metrology Institutes (NMIs). The NMIs METAS, Centre Technique des Industries Aérauliques et Thermiques, IPQ, Danish Technological Institute, and VSL have therefore developed and validated primary standards to cover the flow rate range from 0.1 μl/min to at least 1 ml/min. In this article, we describe the different designs and methods of the primary standards of the gravimetric principle and the results obtained at the intercomparison for the upper flow rate range for the various NMIs and Bronkhorst High-Tech, the manufacturer of the transfer standards used.

  16. PGI chicory (Cichorium intybus L.) traceability by means of HRMAS-NMR spectroscopy: a preliminary study.

    PubMed

    Ritota, Mena; Casciani, Lorena; Valentini, Massimiliano

    2013-05-01

    Analytical traceability of PGI and PDO foods (Protected Geographical Indication and Protected Denomination Origin respectively) is one of the most challenging tasks of current applied research. Here we proposed a metabolomic approach based on the combination of (1)H high-resolution magic angle spinning-nuclear magnetic resonance (HRMAS-NMR) spectroscopy with multivariate analysis, i.e. PLS-DA, as a reliable tool for the traceability of Italian PGI chicories (Cichorium intybus L.), i.e. Radicchio Rosso di Treviso and Radicchio Variegato di Castelfranco, also known as red and red-spotted, respectively. The metabolic profile was gained by means of HRMAS-NMR, and multivariate data analysis allowed us to build statistical models capable of providing clear discrimination among the two varieties and classification according to the geographical origin. Based on Variable Importance in Projection values, the molecular markers for classifying the different types of red chicories analysed were found accounting for both the cultivar and the place of origin. © 2012 Society of Chemical Industry.

  17. Establishment of the Co-C Eutectic Fixed-Point Cell for Thermocouple Calibrations at NIMT

    NASA Astrophysics Data System (ADS)

    Ongrai, O.; Elliott, C. J.

    2017-08-01

    In 2015, NIMT first established a Co-C eutectic temperature reference (fixed-point) cell measurement capability for thermocouple calibration to support the requirements of Thailand's heavy industries and secondary laboratories. The Co-C eutectic fixed-point cell is a facility transferred from NPL, where the design was developed through European and UK national measurement system projects. In this paper, we describe the establishment of a Co-C eutectic fixed-point cell for thermocouple calibration at NIMT. This paper demonstrates achievement of the required furnace uniformity, the Co-C plateau realization and the comparison data between NIMT and NPL Co-C cells by using the same standard Pt/Pd thermocouple, demonstrating traceability. The NIMT measurement capability for noble metal type thermocouples at the new Co-C eutectic fixed point (1324.06°C) is estimated to be within ± 0.60 K (k=2). This meets the needs of Thailand's high-temperature thermocouple users—for which previously there has been no traceable calibration facility.

  18. Maintenance of reference standards in the field of viscosity

    NASA Astrophysics Data System (ADS)

    Moşulică, E. A.; Cîrneanu, I.; Constantin, N.; Rucai, V.

    2018-01-01

    Participation in the work of comparison in the field of viscosity, within the program conducted under the jurisdiction of ASTM (American Society for Testing and Materials), D-2 Committee, Subcommittee "Flow Properties," Newtonian Fluids) was necessary to ensure traceability of measuring unit of kinematic viscosity. Results of the comparison of the specialized participating laboratories on 4 continents, has proved annual capability of INM in the transmission unit of kinematic viscosity. Cannon Position Company in the US organizes co-operation program in the field of kinematic viscosity ASTM D 02.07. The company distributes standard substances Cannon viscosity participating laboratories and consolidate the results of the measurements. Physical-chemical laboratory has fully accepted the proposed schedule of the company Cannon. Final report of the comparison showed that in the year 2015 a number of 25 laboratories and institutes of metrology attented to the program.

  19. Cryogenic flow rate measurement with a laser Doppler velocimetry standard

    NASA Astrophysics Data System (ADS)

    Maury, R.; Strzelecki, A.; Auclercq, C.; Lehot, Y.; Loubat, S.; Chevalier, J.; Ben Rayana, F.

    2018-03-01

    A very promising alternative to the state-of-the-art static volume measurements for liquefied natural gas (LNG) custody transfer processes is the dynamic principle of flow metering. As the Designated Institute (DI) of the LNE (‘Laboratoire National de métrologie et d’Essais’, being the French National Metrology Institute) for high-pressure gas flow metering, Cesame-Exadebit is involved in various research and development programs. Within the framework of the first (2010-2013) and second (2014-2017) EURAMET Joint Research Project (JRP), named ‘Metrological support for LNG custody transfer and transport fuel applications’, Cesame-Exadebit explored a novel cryogenic flow metering technology using laser Doppler velocimetry (LDV) as an alternative to ultrasonic and Coriolis flow metering. Cesame-Exadebit is trying to develop this technique as a primary standard for cryogenic flow meters. Currently, cryogenic flow meters are calibrated at ambient temperatures with water. Results are then extrapolated to be in the Reynolds number range of real applications. The LDV standard offers a unique capability to perform online calibration of cryogenic flow meters in real conditions (temperature, pressure, piping and real flow disturbances). The primary reference has been tested on an industrial process in a LNG terminal during truck refuelling. The reference can calibrate Coriolis flow meters being used daily with all the real environmental constraints, and its utilisation is transparent for LNG terminal operators. The standard is traceable to Standard International units and the combined extended uncertainties have been determined and estimated to be lower than 0.6% (an ongoing improvement to reducing the correlation function uncertainty, which has a major impact in the uncertainty estimation).

  20. Traceable Dynamic Calibration of Force Transducers by Primary Means

    PubMed Central

    Vlajic, Nicholas; Chijioke, Ako

    2018-01-01

    We describe an apparatus for traceable, dynamic calibration of force transducers using harmonic excitation, and report calibration measurements of force transducers using this apparatus. In this system, the force applied to the transducer is produced by the acceleration of an attached mass, and is determined according to Newton’s second law, F = ma. The acceleration is measured by primary means, using laser interferometry. The capabilities of this system are demonstrated by performing dynamic calibrations of two shear-web-type force transducers up to a frequency of 2 kHz, with an expanded uncertainty below 1.2 %. We give an accounting of all significant sources of uncertainty, including a detailed consideration of the effects of dynamic tilting (rocking), which is a leading source of uncertainty in such harmonic force calibration systems. PMID:29887643

  1. A New Approach for Spectroradiometric Calibration Consistency on the Ground and in Space

    NASA Technical Reports Server (NTRS)

    Heath, Donald F.; Geprgoev. Geprgo

    2013-01-01

    A Space-based Calibration Transfer Spectroradiometer (SCATS) is combined with a ground calibration spectral albedo radiometric standard which consists of an opaque quartz glass Mie scattering diffuser (MSD) which has very good Lambertian scattering properties in both reflectance and transmittance modes. This system provides the capability for determining long term changes in the spectral albedo calibrations which operate in the solar reflective wavelength region. The spectral albedo calibration would be traceable to the SIRCUS and STARR NIST calibration facilities. The on-orbit radiometric standard is the Sun. The NIST traceable ground spectral albedo calibration is invariant between the ground and on-orbit over the instrument lifetime due to the use of a field of view defining mechanical baffle to differentiate between radiance and irradiance.

  2. MILSTAMP: Military Standard Transportation and Movement Procedures. Volume 1

    DTIC Science & Technology

    1987-03-15

    paragraphs changed. As it is a part of the regulation, the register will serve as a permanent, easily traceable record of all DoD transactions which affect ...resulting from political decisions, natural disasters, strikes, local or national regulatory action, or other actions which may affect normal traffic flow...regulatory action, or other actions which may affect normal traffic flow. (13) Evaluates carrier performance. 3. CONUS Airlift Managers a. The AFLC: (1

  3. The Traceable Radiometry Underpinning Terrestrial and Helio Studies (TRUTHS) mission

    NASA Astrophysics Data System (ADS)

    Green, Paul D.; Fox, Nigel P.; Lobb, Daniel; Friend, Jonathan

    2015-10-01

    TRUTHS (Traceable Radiometry Underpinning Terrestrial- and Helio-Studies) is a proposed small satellite mission to enable a space-based climate observing system capable of delivering data of the quality needed to provide the information needed by policy makers to make robust mitigation and adaptation decisions. This is achieved by embedding trust and confidence in the data and derived information (tied to international standards) from both its own measurements and by upgrading the performance and interoperability of other EO platforms, such as the Sentinels by in-flight reference calibration. TRUTHS would provide measurements of incoming (total and spectrally resolved) and global reflected spectrally and spatially (50 m) solar radiation at the 0.3% uncertainty level. These fundamental climate data products can be convolved into the building blocks for many ECVs and EO applications as envisaged by the 2015 ESA science strategy; in a cost effective manner. We describe the scientific drivers for the TRUTHS mission and how the requirements for the climate benchmarking and cross-calibration reference sensor are both complementary and simply implemented, with a small additional complexity on top of heritage calibration schemes. The calibration scheme components and the route to SI-traceable Earth-reflected solar spectral radiance and solar spectral irradiance are described.

  4. Rollout Strategy to Implement Interoperable Traceability in the Seafood Industry.

    PubMed

    Gooch, Martin; Dent, Benjamin; Sylvia, Gilbert; Cusack, Christopher

    2017-08-01

    Verifying the accuracy and rigor of data exchanged within and between businesses for the purposes of traceability rests on the existence of effective and efficient interoperable information systems that meet users' needs. Interoperability, particularly given the complexities intrinsic to the seafood industry, requires that the systems used by businesses operating along the supply chain share a common technology architecture that is robust, resilient, and evolves as industry needs change. Technology architectures are developed through engaging industry stakeholders in understanding why an architecture is required, the benefits provided to the industry and individual businesses and supply chains, and how the architecture will translate into practical results. This article begins by reiterating the benefits that the global seafood industry can capture by implementing interoperable chain-length traceability and the reason for basing the architecture on a peer-to-peer networked database concept versus more traditional centralized or linear approaches. A summary of capabilities that already exist within the seafood industry that the proposed architecture uses is discussed; and a strategy for implementing the architecture is presented. The 6-step strategy is presented in the form of a critical path. © 2017 Institute of Food Technologists®.

  5. A spectroscopic transfer standard for accurate atmospheric CO measurements

    NASA Astrophysics Data System (ADS)

    Nwaboh, Javis A.; Li, Gang; Serdyukov, Anton; Werhahn, Olav; Ebert, Volker

    2016-04-01

    Atmospheric carbon monoxide (CO) is a precursor of essential climate variables and has an indirect effect for enhancing global warming. Accurate and reliable measurements of atmospheric CO concentration are becoming indispensable. WMO-GAW reports states a compatibility goal of ±2 ppb for atmospheric CO concentration measurements. Therefore, the EMRP-HIGHGAS (European metrology research program - high-impact greenhouse gases) project aims at developing spectroscopic transfer standards for CO concentration measurements to meet this goal. A spectroscopic transfer standard would provide results that are directly traceable to the SI, can be very useful for calibration of devices operating in the field, and could complement classical gas standards in the field where calibration gas mixtures in bottles often are not accurate, available or stable enough [1][2]. Here, we present our new direct tunable diode laser absorption spectroscopy (dTDLAS) sensor capable of performing absolute ("calibration free") CO concentration measurements, and being operated as a spectroscopic transfer standard. To achieve the compatibility goal stated by WMO for CO concentration measurements and ensure the traceability of the final concentration results, traceable spectral line data especially line intensities with appropriate uncertainties are needed. Therefore, we utilize our new high-resolution Fourier-transform infrared (FTIR) spectroscopy CO line data for the 2-0 band, with significantly reduced uncertainties, for the dTDLAS data evaluation. Further, we demonstrate the capability of our sensor for atmospheric CO measurements, discuss uncertainty calculation following the guide to the expression of uncertainty in measurement (GUM) principles and show that CO concentrations derived using the sensor, based on the TILSAM (traceable infrared laser spectroscopic amount fraction measurement) method, are in excellent agreement with gravimetric values. Acknowledgement Parts of this work have been carried out within the European Metrology Research Programme (EMRP) ENV52 project-HIGHGAS (Metrology for high-impact greenhouse gases). The EMRP is jointly funded by the EMRP participating countries within EURAMET and the European Union. References [1] EMRP project ENV52-HIGHGAS (Metrology for high-impact greenhouse gases), available at: http://www.euramet.org/. [2] J. Nwaboh, A. Manninen, J. Mohn, J. C. Petersen, O. Werhahn, and V.Ebert, European Geosciences Union General Assembly 2015, EGU2015-13542, 2015, Vienna Austria

  6. SI-traceable and dynamic reference gas mixtures for water vapour at polar and high troposphere atmospheric levels

    NASA Astrophysics Data System (ADS)

    Guillevic, Myriam; Pascale, Céline; Mutter, Daniel; Wettstein, Sascha; Niederhauser, Bernhard

    2017-04-01

    In the framework of METAS' AtmoChem-ECV project, new facilities are currently being developed to generate reference gas mixtures for water vapour at concentrations measured in the high troposphere and polar regions, in the range 1-20 µmol/mol (ppm). The generation method is dynamic (the mixture is produced continuously over time) and SI-traceable (i.e. the amount of substance fraction in mole per mole is traceable to the definition of SI-units). The generation process is composed of three successive steps. The first step is to purify the matrix gas, nitrogen or synthetic air. Second, this matrix gas is spiked with the pure substance using a permeation technique: a permeation device contains a few grams of pure water in liquid form and loses it linearly over time by permeation through a membrane. In a third step, to reach the desired concentration, the first, high concentration mixture exiting the permeation chamber is then diluted with a chosen flow of matrix gas with one or two subsequent dilution steps. All flows are piloted by mass flow controllers. All parts in contact with the gas mixture are passivated using coated surfaces, to reduce adsorption/desorption processes as much as possible. The mixture can eventually be directly used to calibrate an analyser. The standard mixture produced by METAS' dynamic setup was injected into a chilled mirror from MBW Calibration AG, the designated institute for absolute humidity calibration in Switzerland. The used chilled mirror, model 373LX, is able to measure frost point and sample pressure and therefore calculate the water vapour concentration. This intercomparison of the two systems was performed in the range 4-18 ppm water vapour in synthetic air, at two different pressure levels, 1013.25 hPa and 2000 hPa. We present here METAS' dynamic setup, its uncertainty budget and the first results of the intercomparison with MBW's chilled mirror.

  7. Advanced Mirror Technology Development (AMTD) for Very Large Space Telescopes

    NASA Technical Reports Server (NTRS)

    Stahl, H. Philip

    2013-01-01

    Accomplishments include: Assembled outstanding team from academia, industry and government with expertise in science and space telescope engineering. Derived engineering specifications for monolithic primary mirror from science measurement needs & implementation constraints. Pursuing long-term strategy to mature technologies necessary to enable future large aperture space telescopes. Successfully demonstrated capability to make 0.5 m deep mirror substrate and polish it to UVOIR traceable figure specification.

  8. Traceability of On-Machine Tool Measurement: A Review.

    PubMed

    Mutilba, Unai; Gomez-Acedo, Eneko; Kortaberria, Gorka; Olarra, Aitor; Yagüe-Fabra, Jose A

    2017-07-11

    Nowadays, errors during the manufacturing process of high value components are not acceptable in driving industries such as energy and transportation. Sectors such as aerospace, automotive, shipbuilding, nuclear power, large science facilities or wind power need complex and accurate components that demand close measurements and fast feedback into their manufacturing processes. New measuring technologies are already available in machine tools, including integrated touch probes and fast interface capabilities. They provide the possibility to measure the workpiece in-machine during or after its manufacture, maintaining the original setup of the workpiece and avoiding the manufacturing process from being interrupted to transport the workpiece to a measuring position. However, the traceability of the measurement process on a machine tool is not ensured yet and measurement data is still not fully reliable enough for process control or product validation. The scientific objective is to determine the uncertainty on a machine tool measurement and, therefore, convert it into a machine integrated traceable measuring process. For that purpose, an error budget should consider error sources such as the machine tools, components under measurement and the interactions between both of them. This paper reviews all those uncertainty sources, being mainly focused on those related to the machine tool, either on the process of geometric error assessment of the machine or on the technology employed to probe the measurand.

  9. RTD-based Material Tracking in a Fully-Continuous Dry Granulation Tableting Line.

    PubMed

    Martinetz, M C; Karttunen, A-P; Sacher, S; Wahl, P; Ketolainen, J; Khinast, J G; Korhonen, O

    2018-06-06

    Continuous manufacturing (CM) offers quality and cost-effectiveness benefits over currently dominating batch processing. One challenge that needs to be addressed when implementing CM is traceability of materials through the process, which is needed for the batch/lot definition and control strategy. In this work the residence time distributions (RTD) of single unit operations (blender, roller compactor and tablet press) of a continuous dry granulation tableting line were captured with NIR based methods at selected mass flow rates to create training data. RTD models for continuous operated unit operations and the entire line were developed based on transfer functions. For semi-continuously operated bucket conveyor and pneumatic transport an assumption based the operation frequency was used. For validation of the parametrized process model, a pre-defined API step change and its propagation through the manufacturing line was computed and compared to multi-scale experimental runs conducted with the fully assembled continuous operated manufacturing line. This novel approach showed a very good prediction power at the selected mass flow rates for a complete continuous dry granulation line. Furthermore, it shows and proves the capabilities of process simulation as a tool to support development and control of pharmaceutical manufacturing processes. Copyright © 2018. Published by Elsevier B.V.

  10. Modeling and Implementation of Cattle/Beef Supply Chain Traceability Using a Distributed RFID-Based Framework in China.

    PubMed

    Liang, Wanjie; Cao, Jing; Fan, Yan; Zhu, Kefeng; Dai, Qiwei

    2015-01-01

    In recent years, traceability systems have been developed as effective tools for improving the transparency of supply chains, thereby guaranteeing the quality and safety of food products. In this study, we proposed a cattle/beef supply chain traceability model and a traceability system based on radio frequency identification (RFID) technology and the EPCglobal network. First of all, the transformations of traceability units were defined and analyzed throughout the cattle/beef chain. Secondly, we described the internal and external traceability information acquisition, transformation, and transmission processes throughout the beef supply chain in detail, and explained a methodology for modeling traceability information using the electronic product code information service (EPCIS) framework. Then, the traceability system was implemented based on Fosstrak and FreePastry software packages, and animal ear tag code and electronic product code (EPC) were employed to identify traceability units. Finally, a cattle/beef supply chain included breeding business, slaughter and processing business, distribution business and sales outlet was used as a case study to evaluate the beef supply chain traceability system. The results demonstrated that the major advantages of the traceability system are the effective sharing of information among business and the gapless traceability of the cattle/beef supply chain.

  11. Modeling and Implementation of Cattle/Beef Supply Chain Traceability Using a Distributed RFID-Based Framework in China

    PubMed Central

    Liang, Wanjie; Cao, Jing; Fan, Yan; Zhu, Kefeng; Dai, Qiwei

    2015-01-01

    In recent years, traceability systems have been developed as effective tools for improving the transparency of supply chains, thereby guaranteeing the quality and safety of food products. In this study, we proposed a cattle/beef supply chain traceability model and a traceability system based on radio frequency identification (RFID) technology and the EPCglobal network. First of all, the transformations of traceability units were defined and analyzed throughout the cattle/beef chain. Secondly, we described the internal and external traceability information acquisition, transformation, and transmission processes throughout the beef supply chain in detail, and explained a methodology for modeling traceability information using the electronic product code information service (EPCIS) framework. Then, the traceability system was implemented based on Fosstrak and FreePastry software packages, and animal ear tag code and electronic product code (EPC) were employed to identify traceability units. Finally, a cattle/beef supply chain included breeding business, slaughter and processing business, distribution business and sales outlet was used as a case study to evaluate the beef supply chain traceability system. The results demonstrated that the major advantages of the traceability system are the effective sharing of information among business and the gapless traceability of the cattle/beef supply chain. PMID:26431340

  12. Test Plan for a Calibration Demonstration System for the Reflected Solar Instrument for the Climate Absolute Radiance and Refractivity Observatory

    NASA Technical Reports Server (NTRS)

    Thome, Kurtis; McCorkel, Joel; Hair, Jason; McAndrew, Brendan; Daw, Adrian; Jennings, Donald; Rabin, Douglas

    2012-01-01

    The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission addresses the need to observe high-accuracy, long-term climate change trends and to use decadal change observations as the most critical method to determine the accuracy of climate change. One of the major objectives of CLARREO is to advance the accuracy of SI traceable absolute calibration at infrared and reflected solar wavelengths. This advance is required to reach the on-orbit absolute accuracy required to allow climate change observations to survive data gaps while remaining sufficiently accurate to observe climate change to within the uncertainty of the limit of natural variability. While these capabilities exist at NIST in the laboratory, there is a need to demonstrate that it can move successfully from NIST to NASA and/or instrument vendor capabilities for future spaceborne instruments. The current work describes the test plan for the Solar, Lunar for Absolute Reflectance Imaging Spectroradiometer (SOLARIS) which is the calibration demonstration system (CDS) for the reflected solar portion of CLARREO. The goal of the CDS is to allow the testing and evaluation of calibration approaches , alternate design and/or implementation approaches and components for the CLARREO mission. SOLARIS also provides a test-bed for detector technologies, non-linearity determination and uncertainties, and application of future technology developments and suggested spacecraft instrument design modifications. The end result of efforts with the SOLARIS CDS will be an SI-traceable error budget for reflectance retrieval using solar irradiance as a reference and methods for laboratory-based, absolute calibration suitable for climate-quality data collections. The CLARREO mission addresses the need to observe high-accuracy, long-term climate change trends and advance the accuracy of SI traceable absolute calibration. The current work describes the test plan for the SOLARIS which is the calibration demonstration system for the reflected solar portion of CLARREO. SOLARIS provides a test-bed for detector technologies, non-linearity determination and uncertainties, and application of future technology developments and suggested spacecraft instrument design modifications. The end result will be an SI-traceable error budget for reflectance retrieval using solar irradiance as a reference and methods for laboratory-based, absolute calibration suitable for climate-quality data collections.

  13. Traceability

    PubMed Central

    2010-01-01

    The importance of effective and timely traceability in both the recall of substances of human origin (blood, cells, tissues and organs) implicated in infectious transmission, and in the prevention of inappropriate use of substances of human origin is now well recognised. However, traceability remains poorly understood and inadequately controlled in many cases. In particular there is: a lack of appreciation of the complexity of the traceability pathway; a fragmented approach to traceability; and, an assumption that traceability data is static. The traceability path for a single tissue donor may involve dozens or even hundreds of different organizations, each responsible for one segment of the path. Whilst responsibility within each organization may be clearly defined, responsibility for maintaining the interfaces between organizations is often less clear. Traceability is seldom regarded in a holistic manner, the assumption being made that if each segment of the pathway is correctly maintained then the full path will be intact. End to end traceability audits are not routinely performed, and the only true test of the trail occurs when recall is required—often with inadequate results. PMID:20628821

  14. The Expanding Role of Traceability in Seafood: Tools and Key Initiatives.

    PubMed

    Lewis, Sara G; Boyle, Mariah

    2017-08-01

    In the last decade, a range of drivers within the seafood sector have incentivized the application of traceability to issues beyond food safety and inventory management. Some of the issues motivating the expanded use of traceability within the global seafood sector include: increased media attention on the legal and social risks within some seafood supply chains, governmental traceability requirements, private-sector sustainability commitments, and others. This article begins with an overview of these topics in the seafood industry, and why many nongovernment organizations (NGOs), companies, and government actors have turned to traceability as a tool to address them. We discuss how traceability connects to key requirements of environmental sustainability and social responsibility. Later, we review the range of traceability services, tools, software solutions, and the due diligence measures that are currently being leveraged within the seafood sector. The paper concludes with a discussion of several NGO- and industry-led traceability initiatives that are examples of seafood traceability improvements. © 2017 Institute of Food Technologists®.

  15. A Theoretical Manpower Optimization Model for the Air Force Installation Contracting Agency (AFICA)

    DTIC Science & Technology

    2017-12-01

    development and enterprise-wide market intelligence. The theoretical manpower model proposed by this project optimizes manpower in respect to contracting...procurement needs and/or more effectively leverage spend, market position, market knowledge (e.g., price benchmarks), and capabilities (e.g., IT...CONS level because the process savings are not clearly traceable to a contract action. For example, to augment the market intelligence of category

  16. Advancing Test Capabilities at NASA Wind Tunnels

    NASA Technical Reports Server (NTRS)

    Bell, James

    2015-01-01

    NASA maintains twelve major wind tunnels at three field centers capable of providing flows at 0.1 M 10 and unit Reynolds numbers up to 45106m. The maintenance and enhancement of these facilities is handled through a unified management structure under NASAs Aeronautics and Evaluation and Test Capability (AETC) project. The AETC facilities are; the 11x11 transonic and 9x7 supersonic wind tunnels at NASA Ames; the 10x10 and 8x6 supersonic wind tunnels, 9x15 low speed tunnel, Icing Research Tunnel, and Propulsion Simulator Laboratory, all at NASA Glenn; and the National Transonic Facility, Transonic Dynamics Tunnel, LAL aerothermodynamics laboratory, 8 High Temperature Tunnel, and 14x22 low speed tunnel, all at NASA Langley. This presentation describes the primary AETC facilities and their current capabilities, as well as improvements which are planned over the next five years. These improvements fall into three categories. The first are operations and maintenance improvements designed to increase the efficiency and reliability of the wind tunnels. These include new (possibly composite) fan blades at several facilities, new temperature control systems, and new and much more capable facility data systems. The second category of improvements are facility capability advancements. These include significant improvements to optical access in wind tunnel test sections at Ames, improvements to test section acoustics at Glenn and Langley, the development of a Supercooled Large Droplet capability for icing research, and the development of an icing capability for large engine testing. The final category of improvements consists of test technology enhancements which provide value across multiple facilities. These include projects to increase balance accuracy, provide NIST-traceable calibration characterization for wind tunnels, and to advance optical instruments for Computational Fluid Dynamics (CFD) validation. Taken as a whole, these individual projects provide significant enhancements to NASA capabilities in ground-based testing. They ensure that these wind tunnels will provide accurate and relevant experimental data for years to come, supporting both NASAs mission and the missions of our government and industry customers.

  17. [Current progress in food geographical origin traceability by near infrared spectroscopy technology].

    PubMed

    Ma, Dong-Hong; Wang, Xi-Chang; Liu, Li-Ping; Liu, Yuan

    2011-04-01

    The geographical origin traceability of food, an important part of traceability system, is effective in protecting the quality and safety of foodstuffs. Near-infrared spectroscopy (NIR), which is a powerful technique for geographical origin traceability, has attracted extensive attention by scientists due to its speediness, non-pollution and simple operation. This paper presents the advantages and disadvantages of techniques that have been used for food geographical origin traceability. The basic principles of NIR and its applications in different food geographical origin traceability are presented too. Furthermore, problems in applications are analyzed and the future development trends are discussed.

  18. Traceability of On-Machine Tool Measurement: A Review

    PubMed Central

    Gomez-Acedo, Eneko; Kortaberria, Gorka; Olarra, Aitor

    2017-01-01

    Nowadays, errors during the manufacturing process of high value components are not acceptable in driving industries such as energy and transportation. Sectors such as aerospace, automotive, shipbuilding, nuclear power, large science facilities or wind power need complex and accurate components that demand close measurements and fast feedback into their manufacturing processes. New measuring technologies are already available in machine tools, including integrated touch probes and fast interface capabilities. They provide the possibility to measure the workpiece in-machine during or after its manufacture, maintaining the original setup of the workpiece and avoiding the manufacturing process from being interrupted to transport the workpiece to a measuring position. However, the traceability of the measurement process on a machine tool is not ensured yet and measurement data is still not fully reliable enough for process control or product validation. The scientific objective is to determine the uncertainty on a machine tool measurement and, therefore, convert it into a machine integrated traceable measuring process. For that purpose, an error budget should consider error sources such as the machine tools, components under measurement and the interactions between both of them. This paper reviews all those uncertainty sources, being mainly focused on those related to the machine tool, either on the process of geometric error assessment of the machine or on the technology employed to probe the measurand. PMID:28696358

  19. Requirement Development Process and Tools

    NASA Technical Reports Server (NTRS)

    Bayt, Robert

    2017-01-01

    Requirements capture the system-level capabilities in a set of complete, necessary, clear, attainable, traceable, and verifiable statements of need. Requirements should not be unduly restrictive, but should set limits that eliminate items outside the boundaries drawn, encourage competition (or alternatives), and capture source and reason of requirement. If it is not needed by the customer, it is not a requirement. They establish the verification methods that will lead to product acceptance. These must be reproducible assessment methods.

  20. [Traceability of labile blood products in Morocco: experience of the Ibn-Sina hospital of Rabat between 1999 and 2010].

    PubMed

    Ouadghiri, S; Atouf, O; Brick, C; Benseffaj, N; Essakalli, M

    2012-02-01

    The blood transfusion and haemovigilance service of the Ibn-Sina hospital in Rabat (Morocco) was created 1997. This unit manages the pretransfusional tests, distribution of blood products, traceability and haemovigilance. The objective of this study was to analyze, over a period of 12years, the traceability of blood products delivered in our hospital and the measures used to improve feedback information. This is a retrospective study conducted between 1999 and 2010. Traceability rate was calculated from the feedback of traceability forms supplied with blood products (number of blood products noted on traceability forms on the total number of delivered product). To improve traceability rate, several actions were undertaken: one-time training, awareness campaigns and call phones asking for feedback information. Between 1999 and 2010, the service has delivered 173,858 blood products. The average rate of traceability during this period was 13.4 %. Traceability rate varies widely over time (5.2 % in 1999, 15.5 % in 2010) and shows a maximum value of 27.2 % in 2005. Feedback information is lower in emergency departments than in medical and surgical services. Feedback information about traceability in Ibn-Sina hospital remains very poor despite the measures used. Other actions, such as continuous education courses, low enforcement and informatisation should be considered. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  1. Traceability of biotech-derived animals: application of DNA technology.

    PubMed

    Loftus, R

    2005-04-01

    Traceability is increasingly becoming standard across the agri-food industry, largely driven by recent food crises and the consequent demands for transparency within the food chain. This is leading to the development of a range of traceability concepts and technologies adapted to different industry needs. Experience with genetically modified plants has shown that traceability can play a role in increasing public confidence in biotechnology, and might similarly help allay concerns relating to the development of animal biotechnology. Traceability also forms an essential component of any risk management strategy and is a key requirement for post-marketing surveillance. Given the diversity of traceability concepts and technologies available, consideration needs to be given to the scope and precision of traceability systems for animal biotechnology. Experience to date has shown that conventional tagging and labelling systems can incorporate levels of error and may not have sufficient precision for biotech-derived animals. Deoxyribonucleic acid (DNA) technology can overcome these difficulties by tracing animals and animal by-products through their DNA code rather than an associated label. This offers the possibility of tracing some by-products of animal biotechnology through the supply chain back to source animals, offering unprecedented levels of traceability. Developments in both DNA sampling and analysis technology are making large-scale applications of DNA traceability increasingly cost effective and feasible, and are likely to lead to a broader uptake of DNA traceability concepts.

  2. Performance Prediction of a MongoDB-Based Traceability System in Smart Factory Supply Chains

    PubMed Central

    Kang, Yong-Shin; Park, Il-Ha; Youm, Sekyoung

    2016-01-01

    In the future, with the advent of the smart factory era, manufacturing and logistics processes will become more complex, and the complexity and criticality of traceability will further increase. This research aims at developing a performance assessment method to verify scalability when implementing traceability systems based on key technologies for smart factories, such as Internet of Things (IoT) and BigData. To this end, based on existing research, we analyzed traceability requirements and an event schema for storing traceability data in MongoDB, a document-based Not Only SQL (NoSQL) database. Next, we analyzed the algorithm of the most representative traceability query and defined a query-level performance model, which is composed of response times for the components of the traceability query algorithm. Next, this performance model was solidified as a linear regression model because the response times increase linearly by a benchmark test. Finally, for a case analysis, we applied the performance model to a virtual automobile parts logistics. As a result of the case study, we verified the scalability of a MongoDB-based traceability system and predicted the point when data node servers should be expanded in this case. The traceability system performance assessment method proposed in this research can be used as a decision-making tool for hardware capacity planning during the initial stage of construction of traceability systems and during their operational phase. PMID:27983654

  3. Performance Prediction of a MongoDB-Based Traceability System in Smart Factory Supply Chains.

    PubMed

    Kang, Yong-Shin; Park, Il-Ha; Youm, Sekyoung

    2016-12-14

    In the future, with the advent of the smart factory era, manufacturing and logistics processes will become more complex, and the complexity and criticality of traceability will further increase. This research aims at developing a performance assessment method to verify scalability when implementing traceability systems based on key technologies for smart factories, such as Internet of Things (IoT) and BigData. To this end, based on existing research, we analyzed traceability requirements and an event schema for storing traceability data in MongoDB, a document-based Not Only SQL (NoSQL) database. Next, we analyzed the algorithm of the most representative traceability query and defined a query-level performance model, which is composed of response times for the components of the traceability query algorithm. Next, this performance model was solidified as a linear regression model because the response times increase linearly by a benchmark test. Finally, for a case analysis, we applied the performance model to a virtual automobile parts logistics. As a result of the case study, we verified the scalability of a MongoDB-based traceability system and predicted the point when data node servers should be expanded in this case. The traceability system performance assessment method proposed in this research can be used as a decision-making tool for hardware capacity planning during the initial stage of construction of traceability systems and during their operational phase.

  4. A new portable generator to dynamically produce SI-traceable reference gas mixtures for VOCs and water vapour at atmospheric concentration

    NASA Astrophysics Data System (ADS)

    Guillevic, Myriam; Pascale, Céline; Ackermann, Andreas; Leuenberger, Daiana; Niederhauser, Bernhard

    2016-04-01

    In the framework of the KEY-VOCs and AtmoChem-ECV projects, we are currently developing new facilities to dynamically generate reference gas mixtures for a variety of reactive compounds, at concentrations measured in the atmosphere and in a SI-traceable way (i.e. the amount of substance fraction in mole per mole is traceable to SI-units). Here we present the realisation of such standards for water vapour in the range 1-10 μmol/mol and for volatile organic compounds (VOCs) such as limonene, alpha-pinene, MVK, MEK, in the nmol/mol range. The matrix gas can be nitrogen or synthetic air. Further development in gas purification techniques could make possible to use purified atmospheric air as carrier gas. The method is based on permeation and dynamic dilution: one permeator containing a pure substance (either water, limonene, MVK, MEK or α-pinene) is kept into a permeation chamber with a constant gas flow. The mass loss is precisely calibrated using a magnetic suspension balance. The carrier gas is purified beforehand from the compounds of interest to the required level, using commercially available purification cartridges. This primary mixture is then diluted to reach the required amount of substance fraction. All flows are piloted by mass flow controllers which makes the production process flexible and easily adaptable to generate the required concentration. All parts in contact with the gas mixture are passivated using coated surfaces, to reduce adsorption/desorption processes as much as possible. Two setups are currently developed: one already built and fixed in our laboratory in Bern as well as a portable generator that is still under construction and that could be used anywhere in the field. The permeation chamber of the portable generator has multiple individual cells allowing the generation of mixtures up to 5 different components if needed. Moreover the presented technique can be adapted and applied to a large variety of molecules (e.g., NO2, BTEX, CFCs, HCFCs, HFCs and other refrigerants) and is particularly suitable for gas species and/or concentration ranges that are not stable in cylinders.

  5. Traceability and Risk Analysis Strategies for Addressing Counterfeit Electronics in Supply Chains for Complex Systems.

    PubMed

    DiMase, Daniel; Collier, Zachary A; Carlson, Jinae; Gray, Robin B; Linkov, Igor

    2016-10-01

    Within the microelectronics industry, there is a growing concern regarding the introduction of counterfeit electronic parts into the supply chain. Even though this problem is widespread, there have been limited attempts to implement risk-based approaches for testing and supply chain management. Supply chain risk management tends to focus on the highly visible disruptions of the supply chain instead of the covert entrance of counterfeits; thus counterfeit risk is difficult to mitigate. This article provides an overview of the complexities of the electronics supply chain, and highlights some gaps in risk assessment practices. In particular, this article calls for enhanced traceability capabilities to track and trace parts at risk through various stages of the supply chain. Placing the focus on risk-informed decision making through the following strategies is needed, including prioritization of high-risk parts, moving beyond certificates of conformance, incentivizing best supply chain management practices, adoption of industry standards, and design and management for supply chain resilience. © 2016 Society for Risk Analysis.

  6. An Optical Frequency Comb Tied to GPS for Laser Frequency/Wavelength Calibration

    PubMed Central

    Stone, Jack A.; Egan, Patrick

    2010-01-01

    Optical frequency combs can be employed over a broad spectral range to calibrate laser frequency or vacuum wavelength. This article describes procedures and techniques utilized in the Precision Engineering Division of NIST (National Institute of Standards and Technology) for comb-based calibration of laser wavelength, including a discussion of ancillary measurements such as determining the mode order. The underlying purpose of these calibrations is to provide traceable standards in support of length measurement. The relative uncertainty needed to fulfill this goal is typically 10−8 and never below 10−12, very modest requirements compared to the capabilities of comb-based frequency metrology. In this accuracy range the Global Positioning System (GPS) serves as an excellent frequency reference that can provide the traceable underpinning of the measurement. This article describes techniques that can be used to completely characterize measurement errors in a GPS-based comb system and thus achieve full confidence in measurement results. PMID:27134794

  7. Fluid-flow-rate metrology: laboratory uncertainties and traceabilities

    NASA Astrophysics Data System (ADS)

    Mattingly, G. E.

    1991-03-01

    Increased concerns for improved fluid flowrate measurement are driving the fluid metering community-meter manufacturers and users alike-to search for better verification and documentation for their fluid measurements. These concerns affect both our domestic and international market places they permeate our technologies - aerospace chemical processes automotive bioengineering etc. They involve public health and safety and they impact our national defense. These concerns are based upon the rising value of fluid resources and products and the importance of critical material accountability. These values directly impact the accuracy needs of fluid buyers and sellers in custody transfers. These concerns impact the designers and operators of chemical process systems where control and productivity optimization depend critically upon measurement precision. Public health and safety depend upon the quality of numerous pollutant measurements - both liquid and gaseous. The performance testing of engines - both automotive and aircraft are critically based upon accurate fuel measurements - both liquid and oxidizer streams. Fluid flowrate measurements are established differently from counterparts in length and mass measurement systems because these have the benefits of " identity" standards. For rate measurement systems the metrology is based upon " derived standards" . These use facilities and transfer standards which are designed built characterized and used to constitute basic measurement capabilities and quantify performance - accuracy and precision. Because " identity standards" do not exist for flow measurements facsimiles or equivalents must

  8. The implementation of traceability systems.

    PubMed

    Ammendrup, S; Barcos, L O

    2006-08-01

    Traceability is a tool to help countries meet their objectives of controlling, preventing and eradicating animal diseases. This article sets out the required steps in a traceability system. Before designing a system of traceability, one must identify the different characteristics that need to be traced throughout the various steps in the food production chain. The interaction between different sectors in defining the objectives and the resulting needs of a traceability system is fundamental. A clear legal framework is also indispensable. European Union (EU) legislation requires identification and registration for cattle, pigs, sheep and goats. For intra-EU trade these animals must be accompanied by a health certificate providing information on their identity and health status. The required identification is harmonised on an EU-wide basis with the aim of ensuring traceability for veterinary purposes. Furthermore EU legislation requires that the traceability of food, feed and food-producing animals be established at all stages of production.

  9. High Sensitivity Optomechanical Reference Accelerometer over 10 kHz

    DTIC Science & Technology

    2014-06-05

    bandwidth of 10 kHz and is traceable. We have incorporated a Fabry-P erot fiber-optic micro-cavity that is currently capable of measuring the test-mass...10 kHz- bandwidth requires displacement detection sensitivities at levels of 10 16 m= Hz p . Optical detection schemes, such as Fabry-P erot ...based micro- mirror Fabry-P erot cavity19,20 was built to operate in reflec- tion as the optical sensor. The mechanical oscillator ground platform and

  10. Large format focal plane array integration with precision alignment, metrology and accuracy capabilities

    NASA Astrophysics Data System (ADS)

    Neumann, Jay; Parlato, Russell; Tracy, Gregory; Randolph, Max

    2015-09-01

    Focal plane alignment for large format arrays and faster optical systems require enhanced precision methodology and stability over temperature. The increase in focal plane array size continues to drive the alignment capability. Depending on the optical system, the focal plane flatness of less than 25μm (.001") is required over transition temperatures from ambient to cooled operating temperatures. The focal plane flatness requirement must also be maintained in airborne or launch vibration environments. This paper addresses the challenge of the detector integration into the focal plane module and housing assemblies, the methodology to reduce error terms during integration and the evaluation of thermal effects. The driving factors influencing the alignment accuracy include: datum transfers, material effects over temperature, alignment stability over test, adjustment precision and traceability to NIST standard. The FPA module design and alignment methodology reduces the error terms by minimizing the measurement transfers to the housing. In the design, the proper material selection requires matched coefficient of expansion materials minimizes both the physical shift over temperature as well as lowering the stress induced into the detector. When required, the co-registration of focal planes and filters can achieve submicron relative positioning by applying precision equipment, interferometry and piezoelectric positioning stages. All measurements and characterizations maintain traceability to NIST standards. The metrology characterizes the equipment's accuracy, repeatability and precision of the measurements.

  11. Traceability in healthcare: crossing boundaries.

    PubMed

    Lovis, C

    2008-01-01

    This paper is a survey on the problem of traceability in healthcare. Traceability covers many different aspects and its understanding varies among different players. In supply chains and retails, traceability usually covers aspects pertaining to logistics. The challenge is to keep trace of objects manufactured, to track their locations in a production and distribution processes. In food industry, traceability has received a lot of attention because of public health problems related to infectious diseases. For instance, in Europe, the challenge of traceability has been to build the tracking of meat, from the living animal to the shell. In the health sector, traceability has mostly been involved in patient safety around human products such as blood derivates contaminants or implanted devices and prosthesis such as mammary implants. There are growing interests involving traceability in health related to drug safety, including the problem of counterfeited drugs, and to privacy. Traceability is also increasingly seen as a mean to improve efficiency of the logistics of care and a way to better understand costs and usage of resources. This survey is reviewing the literature and proposes a discussion based on the real use and needs of traceability in a large teaching hospital. Traceability in healthcare is at the crossroads of numerous needs. It is therefore of particular complexity and raises many new challenges. Identification management and entity tracking, from serialization of consumers' good production in the supply chains, to the identification of actors, patients, care providers, locations and processes is a huge effort, tackling economical, political, ethical and technical challenges. New requirements are needed, not usually met in the supply chain, such as serialization and persistence in time. New problems arise, such as privacy and legal frameworks. There are growing needs to increase traceability for drug products, related to drug safety, counterfeited drugs, and to privacy. Technical problems around reliability, robustness and efficiency of carriers are still to be resolved. There is a lot at stakes. Traceability is a major aspect of the future in healthcare and requires the attention of the community of medical informatics.

  12. Calibrating the Helium Pressurization System for the Space Shuttle Liquid-Hydrogen Tank

    NASA Technical Reports Server (NTRS)

    2008-01-01

    Analysis of the results from the STS-114 tanking tests and subsequent launch called into question existing thermal and mass models of helium pressurization of the liquid hydrogen tank. This hydrogen tank, which makes up the bottom two-thirds of the External Tank, is pressurized prior to launch to avoid cavitation in the Shuttle Main Engine pumps. At about 2 minutes prior to launch, the main vent valve is closed, and pressurized helium flows into the tank ullage space to achieve set point pressure. As the helium gas cools, its pressure drops, calling for additional helium. Subsequent helium flows are provided in short, timed pulses. The number of pulses is taken as a rough leak indicator. An analysis of thermal models by Marshall Space Flight Center showed considerable uncertainty in the pressure-versus-time behavior of the helium ullage space and the ability to predict the number of pulses normally expected. Kennedy Space Center proposed to calibrate the dime-sized orifice, which together with valves, controls the helium flow quantity (Figure 1). Pressure and temperature sensors were installed to provide upstream and downstream measurements necessary to compute flow rate based on the orifice discharge coefficient. An assessment of flow testing with helium indicated an extremely costly use of this critical resource. In order to reduce costs, we proposed removing the orifices from each Mobile Launcher Platform (MLP) and asking Colorado Engineering Experiment Station Inc. (CEESI) to calibrate the flow. CEESI has a high-pressure air flow system with traceable flow meters capable of handling the large flow rates. However, literature research indicated that square-edged orifices of small diameters often exhibit significant hysteresis and nonrepeatability in the vicinity of choked or sonic flow. Fortunately, the MLP orifices behaved relatively well in testing (Figure 2). Using curve fitting of the air-flow data, in conjunction with ASME orifice modeling equations, a method of relating the helium mass flow to measured air flow data was obtained. This analysis showed that the highest uncertainty in flow occurred in the vicinity of the choking pressure ratio, as would be expected. In addition, analysis of typical flow pulses showed that most of the helium flow occurred either well below or well above this uncertain area. The final result is the ability to provide postlaunch estimates of helium mass flows that are within 1.5 percent of the actual value.

  13. The AEDC aerospace chamber 7V: An advanced test capability for infrared surveillance and seeker sensors

    NASA Technical Reports Server (NTRS)

    Simpson, W. R.

    1994-01-01

    An advanced sensor test capability is now operational at the Air Force Arnold Engineering Development Center (AEDC) for calibration and performance characterization of infrared sensors. This facility, known as the 7V, is part of a broad range of test capabilities under development at AEDC to provide complete ground test support to the sensor community for large-aperture surveillance sensors and kinetic kill interceptors. The 7V is a state-of-the-art cryo/vacuum facility providing calibration and mission simulation against space backgrounds. Key features of the facility include high-fidelity scene simulation with precision track accuracy and in-situ target monitoring, diffraction limited optical system, NIST traceable broadband and spectral radiometric calibration, outstanding jitter control, environmental systems for 20 K, high-vacuum, low-background simulation, and an advanced data acquisition system.

  14. The perceived value of dairy product traceability in modern society: An exploratory study.

    PubMed

    Charlebois, Sylvain; Haratifar, Sanaz

    2015-05-01

    The current study assessed the perceived value of food traceability in modern society by young consumers. After experiencing numerous recalls and food safety-related incidences, consumers are increasingly aware of the tools available to mitigate risks. Food traceability has been associated with food safety procedures for many years, but recent high-profile cases of food fraud around the world have given traceability a different strategic purpose. Focusing solely on dairy products, our survey results offer a glimpse of consumer perceptions of traceability as a means to preserve food integrity and authenticity. This study explored the various influences that market-oriented traceability has had on dairy consumers. For example, results show that if the dairy sector could guarantee that their product is in fact organic, 53.8% of respondents who often purchase organic milk would consider always purchasing traceable organic milk. This research produced a quantitative set of information related to the perceived value of food traceability, which could be useful for the creation and development of improved guidelines and better education for consumers. We discuss limitations and suggest areas for new research. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  15. Augmented halal food traceability system: analysis and design using UML

    NASA Astrophysics Data System (ADS)

    Usman, Y. V.; Fauzi, A. M.; Irawadi, T. T.; Djatna, T.

    2018-04-01

    Augmented halal food traceability is expanding the range of halal traceability in food supply chain where currently only available for tracing from the source of raw material to the industrial warehouse or inbound logistic. The halal traceability system must be developed in the integrated form that includes inbound and outbound logistics. The objective of this study was to develop a reliable initial model of integrated traceability system of halal food supply chain. The method was based on unified modeling language (UML) such as use case, sequence, and business process diagram. A goal programming model was formulated considering two objective functions which include (1) minimization of risk of halal traceability failures happened potentially during outbound logistics activities and (2) maximization of quality of halal product information. The result indicates the supply of material is the most important point to be considered in minimizing the risk of failure of halal food traceability system whereas no risk observed in manufacturing and distribution.

  16. Communicating food safety, authenticity and consumer choice. Field experiences.

    PubMed

    Syntesa, Heiner Lehr

    2013-04-01

    The paper reviews patented and non-patented technologies, methods and solutions in the area of food traceability. It pays special attention to the communication of food safety, authenticity and consumer choice. Twenty eight recent patents are reviewed in the areas of (secure) identification, product freshness indicators, meat traceability, (secure) transport of information along the supply chain, country/region/place of origin, automated authentication, supply chain management systems, consumer interaction systems. In addition, solutions and pilot projects are described in the areas of Halal traceability, traceability of bird's nests, cold chain management, general food traceability and other areas.

  17. 21 CFR 820.65 - Traceability.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... QUALITY SYSTEM REGULATION Identification and Traceability § 820.65 Traceability. Each manufacturer of a device that is intended for surgical implant into the body or to support or sustain life and whose...

  18. 21 CFR 820.65 - Traceability.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... QUALITY SYSTEM REGULATION Identification and Traceability § 820.65 Traceability. Each manufacturer of a device that is intended for surgical implant into the body or to support or sustain life and whose...

  19. 21 CFR 820.65 - Traceability.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... QUALITY SYSTEM REGULATION Identification and Traceability § 820.65 Traceability. Each manufacturer of a device that is intended for surgical implant into the body or to support or sustain life and whose...

  20. 21 CFR 820.65 - Traceability.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... QUALITY SYSTEM REGULATION Identification and Traceability § 820.65 Traceability. Each manufacturer of a device that is intended for surgical implant into the body or to support or sustain life and whose...

  1. 21 CFR 820.65 - Traceability.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... QUALITY SYSTEM REGULATION Identification and Traceability § 820.65 Traceability. Each manufacturer of a device that is intended for surgical implant into the body or to support or sustain life and whose...

  2. Consultative Committee on Ionizing Radiation: Impact on Radionuclide Metrology

    PubMed Central

    Karam, L.R.; Ratel, G.

    2016-01-01

    In response to the CIPM MRA, and to improve radioactivity measurements in the face of advancing technologies, the CIPM’s consultative committee on ionizing radiation developed a strategic approach to the realization and validation of measurement traceability for radionuclide metrology. As a consequence, measurement institutions throughout the world have devoted no small effort to establish radionuclide metrology capabilities, supported by active quality management systems and validated through prioritized participation in international comparisons, providing a varied stakeholder community with measurement confidence. PMID:26688351

  3. Portable traceability solution for ground-based calibration of optical instruments

    NASA Astrophysics Data System (ADS)

    El Gawhary, Omar; van Veghel, Marijn; Kenter, Pepijn; van der Leden, Natasja; Dekker, Paul; Revtova, Elena; Heemskerk, Maurice; Trarbach, André; Vink, Ramon; Doyle, Dominic

    2017-11-01

    We present a portable traceability solution for the ground-based optical calibration of earth observation (EO) instruments. Currently, traceability for this type of calibration is typically based on spectral irradiance sources (e.g. FEL lamps) calibrated at a national metrology institute (NMI). Disadvantages of this source-based traceability are the inflexibility in operating conditions of the source, which are limited to the settings used during calibration at the NMI, and the susceptibility to aging, which requires frequent recalibrations, and which cannot be easily checked on-site. The detector-based traceability solution presented in this work uses a portable filter radiometer to calibrate light sources onsite, immediately before and after, or even during instrument calibration. The filter radiometer itself is traceable to the primary standard of radiometry in the Netherlands. We will discuss the design and realization, calibration and performance verification.

  4. Interoperability Using Lightweight Metadata Standards: Service & Data Casting, OpenSearch, OPM Provenance, and Shared SciFlo Workflows

    NASA Astrophysics Data System (ADS)

    Wilson, B. D.; Manipon, G.; Hua, H.; Fetzer, E.

    2011-12-01

    Under several NASA grants, we are generating multi-sensor merged atmospheric datasets to enable the detection of instrument biases and studies of climate trends over decades of data. For example, under a NASA MEASURES grant we are producing a water vapor climatology from the A-Train instruments, stratified by the Cloudsat cloud classification for each geophysical scene. The generation and proper use of such multi-sensor climate data records (CDR's) requires a high level of openness, transparency, and traceability. To make the datasets self-documenting and provide access to full metadata and traceability, we have implemented a set of capabilities and services using known, interoperable protocols. These protocols include OpenSearch, OPeNDAP, Open Provenance Model, service & data casting technologies using Atom feeds, and REST-callable analysis workflows implemented as SciFlo (XML) documents. We advocate that our approach can serve as a blueprint for how to openly "document and serve" complex, multi-sensor CDR's with full traceability. The capabilities and services provided include: - Discovery of the collections by keyword search, exposed using OpenSearch protocol; - Space/time query across the CDR's granules and all of the input datasets via OpenSearch; - User-level configuration of the production workflows so that scientists can select additional physical variables from the A-Train to add to the next iteration of the merged datasets; - Efficient data merging using on-the-fly OPeNDAP variable slicing & spatial subsetting of data out of input netCDF and HDF files (without moving the entire files); - Self-documenting CDR's published in a highly usable netCDF4 format with groups used to organize the variables, CF-style attributes for each variable, numeric array compression, & links to OPM provenance; - Recording of processing provenance and data lineage into a query-able provenance trail in Open Provenance Model (OPM) format, auto-captured by the workflow engine; - Open Publishing of all of the workflows used to generate products as machine-callable REST web services, using the capabilities of the SciFlo workflow engine; - Advertising of the metadata (e.g. physical variables provided, space/time bounding box, etc.) for our prepared datasets as "datacasts" using the Atom feed format; - Publishing of all datasets via our "DataDrop" service, which exploits the WebDAV protocol to enable scientists to access remote data directories as local files on their laptops; - Rich "web browse" of the CDR's with full metadata and the provenance trail one click away; - Advertising of all services as Google-discoverable "service casts" using the Atom format. The presentation will describe our use of the interoperable protocols and demonstrate the capabilities and service GUI's.

  5. Locations of ectopic beats coincide with spatial gradients of NADH in a regional model of low-flow reperfusion.

    PubMed

    Kay, Matthew; Swift, Luther; Martell, Brian; Arutunyan, Ara; Sarvazyan, Narine

    2008-05-01

    We studied the origins of ectopic beats during low-flow reperfusion after acute regional ischemia in excised rat hearts. The left anterior descending coronary artery was cannulated. Perfusate was delivered to the cannula using an high-performance liquid chromatography pump. This provided not only precise control of flow rate but also avoided mechanical artifacts associated with vessel occlusion and deocclusion. Optical mapping of epicardial transmembrane potential served to identify activation wavefronts. Imaging of NADH fluorescence was used to quantify local ischemia. Our experiments suggest that low-flow reperfusion of ischemic myocardium leads to a highly heterogeneous ischemic substrate and that the degree of ischemia between adjacent patches of tissue changes in time. In contrast to transient ectopic activity observed during full-flow reperfusion, persistent ectopic arrhythmias were observed during low-flow reperfusion. The origins of ectopic beats were traceable to areas of high spatial gradients of changes in NADH fluorescence caused by low-flow reperfusion.

  6. An Initial Model of Requirements Traceability an Empirical Study

    DTIC Science & Technology

    1992-09-22

    procedures have been used extensively in the study of human problem-solving, including such areas as general problem-solving behavior, physics problem...heen doing unless you have traceability." " Humans don’t go back to the requirements enough." "Traceabi!ity should be extremely helpful with...by constraints on its usage: ("Traceability needs to be something that humans can work with, not just a whip held over people." "Traceability should

  7. Injection and injection-compression moulding replication capability for the production of polymer lab-on-a-chip with nano structures

    NASA Astrophysics Data System (ADS)

    Calaon, M.; Tosello, G.; Garnaes, J.; Hansen, H. N.

    2017-10-01

    The manufacturing precision and accuracy in the production of polymer lab-on-a-chip components with 100-130 nm deep nanochannels are evaluated using a metrological approach. Replication fidelity on corresponding process fingerprint test nanostructures over different substrates (nickel tool and polymer part) is quantified through traceable atomic force microscope measurements. Dimensions of injection moulded (IM) and injection-compression moulded (ICM) thermoplastic cyclic olefin copolymer nanofeatures are characterized depending on process parameters and four different features positions on a 30  ×  80 mm2 area. Replication capability of IM and ICM technologies are quantified and the products tolerance at the nanometre dimensional scale verified.

  8. Using DNA origami nanorulers as traceable distance measurement standards and nanoscopic benchmark structures.

    PubMed

    Raab, Mario; Jusuk, Ija; Molle, Julia; Buhr, Egbert; Bodermann, Bernd; Bergmann, Detlef; Bosse, Harald; Tinnefeld, Philip

    2018-01-29

    In recent years, DNA origami nanorulers for superresolution (SR) fluorescence microscopy have been developed from fundamental proof-of-principle experiments to commercially available test structures. The self-assembled nanostructures allow placing a defined number of fluorescent dye molecules in defined geometries in the nanometer range. Besides the unprecedented control over matter on the nanoscale, robust DNA origami nanorulers are reproducibly obtained in high yields. The distances between their fluorescent marks can be easily analysed yielding intermark distance histograms from many identical structures. Thus, DNA origami nanorulers have become excellent reference and training structures for superresolution microscopy. In this work, we go one step further and develop a calibration process for the measured distances between the fluorescent marks on DNA origami nanorulers. The superresolution technique DNA-PAINT is used to achieve nanometrological traceability of nanoruler distances following the guide to the expression of uncertainty in measurement (GUM). We further show two examples how these nanorulers are used to evaluate the performance of TIRF microscopes that are capable of single-molecule localization microscopy (SMLM).

  9. Emergency radiobioassay preparedness exercises through the NIST radiochemistry intercomparison program.

    PubMed

    Nour, Svetlana; LaRosa, Jerry; Inn, Kenneth G W

    2011-08-01

    The present challenge for the international emergency radiobioassay community is to analyze contaminated samples rapidly while maintaining high quality results. The National Institute of Standards and Technology (NIST) runs a radiobioassay measurement traceability testing program to evaluate the radioanalytical capabilities of participating laboratories. The NIST Radiochemistry Intercomparison Program (NRIP) started more than 10 years ago, and emergency performance testing was added to the program seven years ago. Radiobioassay turnaround times under the NRIP program for routine production and under emergency response scenarios are 60 d and 8 h, respectively. Because measurement accuracy and sample turnaround time are very critical in a radiological emergency, response laboratories' analytical systems are best evaluated and improved through traceable Performance Testing (PT) programs. The NRIP provides participant laboratories with metrology tools to evaluate their performance and to improve it. The program motivates the laboratories to optimize their methodologies and minimize the turnaround time of their results. Likewise, NIST has to make adjustments and periodical changes in the bioassay test samples in order to challenge the participating laboratories continually. With practice, radioanalytical measurements turnaround time can be reduced to 3-4 h.

  10. Practical Use Of It In Traceability In Food Value Chains

    NASA Astrophysics Data System (ADS)

    Ratcliff, Jon; Boddington, Michael

    Traceability is today considered an essential requirement for the food value chain due to the need to provide consumers with accurate information in the event of food safety recalls, to provide assurance with regard the source and production systems for food products and in certain countries to comply with government legislation. Within an individual business traceability can be quite simple to implement, however, in a global trading market, traceability of the entire supply chain, including logistics is extremely complex. For this reason IT solutions such as TraceTracker have been developed which not only provide electronic solutions for complete traceability but also allow products to be tracked at any point in the supply chain.

  11. 75 FR 24569 - Animal Traceability; Public Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-05

    ... DEPARTMENT OF AGRICULTURE Animal and Plant Health Inspection Service [Docket No. APHIS-2010-0050] Animal Traceability; Public Meetings AGENCY: Animal and Plant Health Inspection Service, USDA. ACTION... input on the new framework being developed for animal disease traceability. Additional meetings are...

  12. 75 FR 33576 - Animal Traceability; Public Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-14

    ... DEPARTMENT OF AGRICULTURE Animal and Plant Health Inspection Service [Docket No. APHIS-2010-0050] Animal Traceability; Public Meetings AGENCY: Animal and Plant Health Inspection Service, USDA. ACTION... the new framework being developed for animal disease traceability. The meetings are being organized by...

  13. 75 FR 47769 - Animal Traceability; Public Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-09

    ... DEPARTMENT OF AGRICULTURE Animal and Plant Health Inspection Service [Docket No. APHIS-2010-0050] Animal Traceability; Public Meetings AGENCY: Animal and Plant Health Inspection Service, USDA. ACTION... the new framework being developed for animal disease traceability. The meetings are being organized by...

  14. 40 CFR 1065.301 - Overview and general provisions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... judgment. (d) Use NIST-traceable standards to the tolerances we specify for calibrations and verifications. Where we specify the need to use NIST-traceable standards, you may alternatively ask for our approval to use international standards that are not NIST-traceable. ...

  15. 40 CFR 1065.301 - Overview and general provisions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... judgment. (d) Use NIST-traceable standards to the tolerances we specify for calibrations and verifications. Where we specify the need to use NIST-traceable standards, you may alternatively ask for our approval to use international standards that are not NIST-traceable. ...

  16. 40 CFR 1065.301 - Overview and general provisions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... judgment. (d) Use NIST-traceable standards to the tolerances we specify for calibrations and verifications. Where we specify the need to use NIST-traceable standards, you may alternatively ask for our approval to use international standards that are not NIST-traceable. ...

  17. 40 CFR 1065.301 - Overview and general provisions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... judgment. (d) Use NIST-traceable standards to the tolerances we specify for calibrations and verifications. Where we specify the need to use NIST-traceable standards, you may alternatively ask for our approval to use international standards that are not NIST-traceable. ...

  18. 40 CFR 1065.301 - Overview and general provisions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... judgment. (d) Use NIST-traceable standards to the tolerances we specify for calibrations and verifications. Where we specify the need to use NIST-traceable standards, you may alternatively ask for our approval to use international standards that are not NIST-traceable. ...

  19. 40 CFR 1065.315 - Pressure, temperature, and dewpoint calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... quantities that are NIST-traceable within 0.5% uncertainty. (2) Temperature. We recommend digital dry-block... errors. We recommend using calibration reference quantities that are NIST-traceable within 0.5... NIST-traceable simulator that is independently calibrated and, as appropriate, cold-junction...

  20. 40 CFR 1065.315 - Pressure, temperature, and dewpoint calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... quantities that are NIST-traceable within 0.5% uncertainty. (2) Temperature. We recommend digital dry-block... errors. We recommend using calibration reference quantities that are NIST-traceable within 0.5... NIST-traceable simulator that is independently calibrated and, as appropriate, cold-junction...

  1. 40 CFR 1065.315 - Pressure, temperature, and dewpoint calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... quantities that are NIST-traceable within 0.5% uncertainty. (2) Temperature. We recommend digital dry-block... errors. We recommend using calibration reference quantities that are NIST-traceable within 0.5... NIST-traceable simulator that is independently calibrated and, as appropriate, cold-junction...

  2. 40 CFR 1065.315 - Pressure, temperature, and dewpoint calibration.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... quantities that are NIST-traceable within 0.5% uncertainty. (2) Temperature. We recommend digital dry-block... errors. We recommend using calibration reference quantities that are NIST-traceable within 0.5... NIST-traceable simulator that is independently calibrated and, as appropriate, cold-junction...

  3. 40 CFR 1065.315 - Pressure, temperature, and dewpoint calibration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... quantities that are NIST-traceable within 0.5% uncertainty. (2) Temperature. We recommend digital dry-block... errors. We recommend using calibration reference quantities that are NIST-traceable within 0.5... NIST-traceable simulator that is independently calibrated and, as appropriate, cold-junction...

  4. Traceability of radiation protection instruments

    NASA Astrophysics Data System (ADS)

    Hino, Y.; Kurosawa, T.

    2007-08-01

    Radiation protection instruments are used in daily measurement of dose and activities in workplaces and environments for safety management. The requirements for calibration certificates with traceability are increasing for these instruments to ensure the consistency and reliabilities of the measurement results. The present traceability scheme of radiation protection instruments for dose and activity measurements is described with related IEC/ISO requirements. Some examples of desirable future calibration systems with recent new technologies are also discussed to establish the traceability with reasonable costs and reliabilities.

  5. Proceedings of the November 2011 Traceability Research Summit: this report is the third in a series on Traceability Summits sponsored by IFT beginning in July 2011.

    PubMed

    Hickey, Caitlin; Bhatt, Tejas

    2013-12-01

    Fifty thought leaders in the area of food traceability met for a 3rd time to discuss methodologies and finalize the principles that define their vision for traceability. Participants in the summit included representatives from industry, trade associations, government, academia, consumer groups, and more. One main focus of this summit included a discussion on the current regulations and voluntary initiatives in place regarding traceability. Overall, it was recognized that the recommendations from this summit group would be more specific and stringent in comparison to these current regulations and initiatives. The participants sought to be leaders in the traceability arena, with their recommendations leading the industry to optimal traceability systems and methods. Participants agreed on many principles for their vision of traceability, emphasizing the importance of access to traceability data. They discussed having industry be asked for "basic" tracing data prior to the need for a large-scale investigation, having standards for sharing data, and having the data in electronic form. Participants foresaw the importance of capturing data electronically in the future, although they recognized that many firms do not currently do this. The group also saw a need for a transition period to implement changes, and to provide implementation training and resource aid to small businesses. Summit participants discussed specific definitions and examples for key data elements and critical tracking events that could be used by industry to capture tracing data at specific points within the supply chain. Overall, participants refined the goals of the summit group and started to identify specific ways to achieve those goals. © 2013 Institute of Food Technologists®

  6. A PetriNet-Based Approach for Supporting Traceability in Cyber-Physical Manufacturing Systems

    PubMed Central

    Huang, Jiwei; Zhu, Yeping; Cheng, Bo; Lin, Chuang; Chen, Junliang

    2016-01-01

    With the growing popularity of complex dynamic activities in manufacturing processes, traceability of the entire life of every product has drawn significant attention especially for food, clinical materials, and similar items. This paper studies the traceability issue in cyber-physical manufacturing systems from a theoretical viewpoint. Petri net models are generalized for formulating dynamic manufacturing processes, based on which a detailed approach for enabling traceability analysis is presented. Models as well as algorithms are carefully designed, which can trace back the lifecycle of a possibly contaminated item. A practical prototype system for supporting traceability is designed, and a real-life case study of a quality control system for bee products is presented to validate the effectiveness of the approach. PMID:26999141

  7. Importance of Requirements Analysis & Traceability to Improve Software Quality and Reduce Cost and Risk

    NASA Technical Reports Server (NTRS)

    Kapoor, Manju M.; Mehta, Manju

    2010-01-01

    The goal of this paper is to emphasize the importance of developing complete and unambiguous requirements early in the project cycle (prior to Preliminary Design Phase). Having a complete set of requirements early in the project cycle allows sufficient time to generate a traceability matrix. Requirements traceability and analysis are the key elements in improving verification and validation process, and thus overall software quality. Traceability can be most beneficial when the system changes. If changes are made to high-level requirements it implies that low-level requirements need to be modified. Traceability ensures that requirements are appropriately and efficiently verified at various levels whereas analysis ensures that a rightly interpreted set of requirements is produced.

  8. A PetriNet-Based Approach for Supporting Traceability in Cyber-Physical Manufacturing Systems.

    PubMed

    Huang, Jiwei; Zhu, Yeping; Cheng, Bo; Lin, Chuang; Chen, Junliang

    2016-03-17

    With the growing popularity of complex dynamic activities in manufacturing processes, traceability of the entire life of every product has drawn significant attention especially for food, clinical materials, and similar items. This paper studies the traceability issue in cyber-physical manufacturing systems from a theoretical viewpoint. Petri net models are generalized for formulating dynamic manufacturing processes, based on which a detailed approach for enabling traceability analysis is presented. Models as well as algorithms are carefully designed, which can trace back the lifecycle of a possibly contaminated item. A practical prototype system for supporting traceability is designed, and a real-life case study of a quality control system for bee products is presented to validate the effectiveness of the approach.

  9. Proceedings of a Meeting on Traceability for Ionizing Radiation Measurements

    NASA Astrophysics Data System (ADS)

    Heaton, H. T., II

    1982-02-01

    General concepts for traceability were presented from several perspectives. The national standards for radiation dosimetry, radioactivity measurements, and neutron measurements were described. Specific programs for achieving traceability to the national standards for radiation measurements in medical, occupational, and environmental applications were summarized.

  10. Whole-chain traceability, is it possible to trace your hamburger to a particular steer, a U. S. perspective.

    PubMed

    Crandall, Philip G; O'Bryan, Corliss A; Babu, Dinesh; Jarvis, Nathan; Davis, Mike L; Buser, Michael; Adam, Brian; Marcy, John; Ricke, Steven C

    2013-10-01

    Traceability through the entire food supply chain from conception to consumption is a pressing need for the food industry, consumers and government regulators. A robust, whole-chain traceability system is needed that will effectively address food quality, food safety and food defense issues by providing real-time, transparent and reliable information from beef production through slaughter and distribution to the consumer. Traceability is an expanding part of the food safety continuum that minimizes the risk of foodborne diseases, assures quality and cold-chain integrity. Traceability can be a positive competitive marketing edge for beef producers who can verify specific quality attributes such as humane production or grass fed or Certified Organic. In this review we address the benefits as well as the remaining issues for whole-chain traceability in the beef industry, with particular focus on ground beef for the markets in the United States. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Making traceability work across the entire food supply chain.

    PubMed

    Bhatt, Tejas; Buckley, Greg; McEntire, Jennifer C; Lothian, Paul; Sterling, Brian; Hickey, Caitlin

    2013-12-01

    The Institute of Food Technologists held Traceability Research Summits on July 14, August 22, and November 1, 2011, to address how to meet the growing requirement for agriculture and food traceability. Each meeting had a group of about 50 individuals who came from food companies, trade associations, local, state, and federal governments, 3rd-party traceability solution providers, not-for-profit corporations, consultants, and consumer groups. They discussed and deliberated the objectives of traceability and the means to develop product tracing in the food system. A total of 70 people participated in the 3 summits. These individuals were invited to participate in a small workgroup responsible for considering the details related to product tracing and presenting draft concepts to the larger group on November 1, 2011, in Chicago. During this meeting, the larger assembly further refined the concepts and came to an agreement on the basic principles and overall design of the desired approach to traceability. © 2013 Institute of Food Technologists®

  12. Worldwide Space Launch Vehicles and Their Mainstage Liquid Rocket Propulsion

    NASA Technical Reports Server (NTRS)

    Rahman, Shamim A.

    2010-01-01

    Space launch vehicle begins with a basic propulsion stage, and serves as a missile or small launch vehicle; many are traceable to the 1945 German A-4. Increasing stage size, and increasingly energetic propulsion allows for heavier payloads and greater. Earth to Orbit lift capability. Liquid rocket propulsion began with use of storable (UDMH/N2O4) and evolved to high performing cryogenics (LOX/RP, and LOX/LH). Growth versions of SLV's rely on strap-on propulsive stages of either solid propellants or liquid propellants.

  13. Selected Tether Applications Cost Model

    NASA Technical Reports Server (NTRS)

    Keeley, Michael G.

    1988-01-01

    Diverse cost-estimating techniques and data combined into single program. Selected Tether Applications Cost Model (STACOM 1.0) is interactive accounting software tool providing means for combining several independent cost-estimating programs into fully-integrated mathematical model capable of assessing costs, analyzing benefits, providing file-handling utilities, and putting out information in text and graphical forms to screen, printer, or plotter. Program based on Lotus 1-2-3, version 2.0. Developed to provide clear, concise traceability and visibility into methodology and rationale for estimating costs and benefits of operations of Space Station tether deployer system.

  14. Cargo Movement Operations System (CMOS) Requirements Traceability Matrix, ECP. Version 2

    DTIC Science & Technology

    1990-06-07

    NO [ ] COMMENT DISPOSITION: COMMENT STATUS: OPEN ( ] CLOSED [ ] ORIGINATOR CONTROL NUMBER: RTM2-0003 PROGRAM OFFICE CONTROL NUMBER: DATA ITEM DISCREPANCY WORKSHEET CDRL NUMBER: A018-02A DATE: 06/07/90 ORIGINATOR NAME: Patrick L. Combs OFFICE SYMBOL: SAIC TELEPHONE NUMBER: 272-2999 SUBSTANTIVE: X EDITORIAL: PAGE NUMBER: E-25 PARA NUMBER: SC122 COMMENT OR RECOMMENDED CHANGE: Delete SS0850 and SS0851 from SC122. RATIONALE: These requirements are not present in all the subordinate system capabilities and, therefore, should not be allocated to

  15. 78 FR 2039 - Traceability for Livestock Moving Interstate

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-09

    ... Inspection Service 9 CFR Parts 71, 77, 78, et al. Traceability for Livestock Moving Interstate; Final Rule #0..., and 86 [Docket No. APHIS-2009-0091] RIN 0579-AD24 Traceability for Livestock Moving Interstate AGENCY: Animal and Plant Health Inspection Service, USDA. ACTION: Final rule. SUMMARY: We are amending the...

  16. 76 FR 50081 - Traceability for Livestock Moving Interstate

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-11

    ... Inspection Service 9 CFR Parts 71, 77, 78, et al. Traceability for Livestock Moving Interstate; Proposed Rule... 90 [Docket No. APHIS-2009-0091] RIN 0579-AD24 Traceability for Livestock Moving Interstate AGENCY: Animal and Plant Health Inspection Service, USDA. ACTION: Proposed rule. SUMMARY: We are proposing to...

  17. Cattle traceability system in Japan for bovine spongiform encephalopathy.

    PubMed

    Sugiura, Katsuaki; Onodera, Takashi

    2008-01-01

    To promote consumer confidence in the safety of beef and to ensure the proper implementation of eradication measures against bovine spongiform encephalopathy (BSE), the Cattle Traceability Law was approved by the Diet in June 2003 and a cattle traceability system has been in operation in Japan since December 2003. The system enables tracing the cohort and offspring animals of a BSE case within 24 h of its detection. The traceability database system also provides distributors, restaurants and consumers with information on the cattle from which the beef that they sell, serve and consume, originate.

  18. How to obtain traceability on optical radiation measurements?

    NASA Astrophysics Data System (ADS)

    Matamoros García, Carlos H.

    2006-02-01

    Traceability to national standards provides confidence in measurements results, granting a guaranty when carrying out governmental rules and when demonstrating conformity with quality requirements such as ISO 9000 or ISO/IEC 17025 (and the Mexican equivalent standards). The appropriate traceability contributes with confidence of the quality of products or services. This paper presents different ways to obtain traceability in Mexico for the optical radiation measurements, mentioning some applications, and highlighting the necessity of having traceability to the appropriate units of the SI. Additionally it present the national standards maintained by Centro Nacional de Metrologia (CENAM), the national metrology institute in Mexico, that give the technical support to Mexican measurements in this field and the international recognition that the personal of the Optics and Radiometry Division had gained in 10 years of development.

  19. Traceability of Boletaceae mushrooms using data fusion of UV-visible and FTIR combined with chemometrics methods.

    PubMed

    Yao, Sen; Li, Tao; Liu, HongGao; Li, JieQing; Wang, YuanZhong

    2018-04-01

    Boletaceae mushrooms are wild-grown edible mushrooms that have high nutrition, delicious flavor and large economic value distributing in Yunnan Province, China. Traceability is important for the authentication and quality assessment of Boletaceae mushrooms. In this study, UV-visible and Fourier transform infrared (FTIR) spectroscopies were applied for traceability of 247 Boletaceae mushroom samples in combination with chemometrics. Compared with a single spectroscopy technique, data fusion strategy can obviously improve the classification performance in partial least square discriminant analysis (PLS-DA) and grid-search support vector machine (GS-SVM) models, for both species and geographical origin traceability. In addition, PLS-DA and GS-SVM models can provide 100.00% accuracy for species traceability and have reliable evaluation parameters. For geographical origin traceability, the accuracy of prediction in the PLS-DA model by data fusion was just 64.63%, but the GS-SVM model based on data fusion was 100.00%. The results demonstrated that the data fusion strategy of UV-visible and FTIR combined with GS-SVM could provide a higher synergic effect for traceability of Boletaceae mushrooms and have a good generalization ability for the comprehensive quality control and evaluation of similar foods. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  20. Traceability in hardness measurements: from the definition to industry

    NASA Astrophysics Data System (ADS)

    Germak, Alessandro; Herrmann, Konrad; Low, Samuel

    2010-04-01

    The measurement of hardness has been and continues to be of significant importance to many of the world's manufacturing industries. Conventional hardness testing is the most commonly used method for acceptance testing and production quality control of metals and metallic products. Instrumented indentation is one of the few techniques available for obtaining various property values for coatings and electronic products in the micrometre and nanometre dimensional scales. For these industries to be successful, it is critical that measurements made by suppliers and customers agree within some practical limits. To help assure this measurement agreement, a traceability chain for hardness measurement traceability from the hardness definition to industry has developed and evolved over the past 100 years, but its development has been complicated. A hardness measurement value not only requires traceability of force, length and time measurements but also requires traceability of the hardness values measured by the hardness machine. These multiple traceability paths are needed because a hardness measurement is affected by other influence parameters that are often difficult to identify, quantify and correct. This paper describes the current situation of hardness measurement traceability that exists for the conventional hardness methods (i.e. Rockwell, Brinell, Vickers and Knoop hardness) and for special-application hardness and indentation methods (i.e. elastomer, dynamic, portables and instrumented indentation).

  1. JWST Mirror Technology Development Results

    NASA Technical Reports Server (NTRS)

    Stahl, H. Philip

    2007-01-01

    Mirror technology is a critical enabling capability for the James Webb Space Telescope (JWST). JWST requires a Primary Mirror Segment Assembly (PMSA) that can survive launch, deploy and align itself to form a 25 square meter collecting area 6.5 meter diameter primary mirror with a 131 nm rms wavefront error at temperatures less than 50K and provide stable optical performance. At the inception of JWST in 1996, such a capability did not exist. A highly successful technology development program was initiated including the Sub-scale Beryllium Mirror Demonstrator (SBMD) and Advanced Mirror System Demonstrator (AMSD) projects. These projects along with flight program activities have matured and demonstrated mirror technology for JWST. Directly traceable prototypes or flight hardware has been built, tested and operated in a relevant environment. This paper summarizes that technology development effort.

  2. Breed traceability of buffalo meat using microsatellite genotyping technique.

    PubMed

    Kannur, Bheemashankar H; Fairoze, Md Nadeem; Girish, P S; Karabasanavar, Nagappa; Rudresh, B H

    2017-02-01

    Although buffalo has emerged as a major meat producing animal in Asia, major research on breed traceability has so far been focused on cattle (beef). This research gap on buffalo breed traceability has impelled development and validation of buffalo breed traceability using a set of eight microsatellite (STR) markers in seven Indian buffalo breeds (Bhadawari, Jaffaarabadi, Murrah, Mehsana, Nagpuri, Pandharpuri and Surti). Probability of sharing same profile by two individuals at a specific locus was computed considering different STR numbers, allele pooling in breed and population. Match probabilities per breed were considered and six most polymorphic loci were genotyped. Out of eight microsatellite markers studied, markers CSSMO47, DRB3 and CSSM060 were found most polymorphic. Developed technique was validated with known and unknown, blood and meat samples; wherein, samples were genetically traced in 24 out of 25 samples tested. Results of this study showed potential applications of the methodology and encourage other researchers to address the problem of buffalo traceability so as to create a world-wide archive of breed specific genotypes. This work is the first report of breed traceability of buffalo meat utilizing microsatellite genotyping technique.

  3. Current Barriers to Large-scale Interoperability of Traceability Technology in the Seafood Sector.

    PubMed

    Hardt, Marah J; Flett, Keith; Howell, Colleen J

    2017-08-01

    Interoperability is a critical component of full-chain digital traceability, but is almost nonexistent in the seafood industry. Using both quantitative and qualitative methodology, this study explores the barriers impeding progress toward large-scale interoperability among digital traceability systems in the seafood sector from the perspectives of seafood companies, technology vendors, and supply chains as a whole. We highlight lessons from recent research and field work focused on implementing traceability across full supply chains and make some recommendations for next steps in terms of overcoming challenges and scaling current efforts. © 2017 Institute of Food Technologists®.

  4. A hierarchical modeling methodology for the definition and selection of requirements

    NASA Astrophysics Data System (ADS)

    Dufresne, Stephane

    This dissertation describes the development of a requirements analysis methodology that takes into account the concept of operations and the hierarchical decomposition of aerospace systems. At the core of the methodology, the Analytic Network Process (ANP) is used to ensure the traceability between the qualitative and quantitative information present in the hierarchical model. The proposed methodology is implemented to the requirements definition of a hurricane tracker Unmanned Aerial Vehicle. Three research objectives are identified in this work; (1) improve the requirements mapping process by matching the stakeholder expectations with the concept of operations, systems and available resources; (2) reduce the epistemic uncertainty surrounding the requirements and requirements mapping; and (3) improve the requirements down-selection process by taking into account the level of importance of the criteria and the available resources. Several challenges are associated with the identification and definition of requirements. The complexity of the system implies that a large number of requirements are needed to define the systems. These requirements are defined early in the conceptual design, where the level of knowledge is relatively low and the level of uncertainty is large. The proposed methodology intends to increase the level of knowledge and reduce the level of uncertainty by guiding the design team through a structured process. To address these challenges, a new methodology is created to flow-down the requirements from the stakeholder expectations to the systems alternatives. A taxonomy of requirements is created to classify the information gathered during the problem definition. Subsequently, the operational and systems functions and measures of effectiveness are integrated to a hierarchical model to allow the traceability of the information. Monte Carlo methods are used to evaluate the variations of the hierarchical model elements and consequently reduce the epistemic uncertainty. The proposed methodology is applied to the design of a hurricane tracker Unmanned Aerial Vehicles to demonstrate the origin and impact of requirements on the concept of operations and systems alternatives. This research demonstrates that the hierarchical modeling methodology provides a traceable flow-down of the requirements from the problem definition to the systems alternatives phases of conceptual design.

  5. [Establishment of traceability system of Chinese medicinal materials' quality].

    PubMed

    Qi, Yao-dong; Gao, Shi-man; Liu, Hai-tao; Li, Xi-wen; Wei, Jian-he; Zhang, Ben-gang; Sun, Xiao-bo; Xiao, Pei-gen

    2015-12-01

    The quality of Chinese medicinal materials relates greatly to the clinical curative effect and security. In order to ensure the quality and safety of Chinese medicinal materials, a systematic and operable traceability system needs to be established. It can realize the whole process of quality and safety management of Chinese medicinal materials "from production to consumption" through recording and inquiring information and recalling defective products, which is an important direction for the future development of traditional Chinese medicine. But it is still at the exploration and trial stage. In this paper, a framework of Chinese medicinal materials' quality and safety traceability system was established on the basis of the domestic and international experience about the construction of food and agricultural products traceability systems. The relationship between traceability system of Chinese medicinal materials' quality and GAP, GMP, GSP was analyzed, and the possible problems and the corresponding solutions were discussed.

  6. Toward fish and seafood traceability: anchovy species determination in fish products by molecular markers and support through a public domain database.

    PubMed

    Jérôme, Marc; Martinsohn, Jann Thorsten; Ortega, Delphine; Carreau, Philippe; Verrez-Bagnis, Véronique; Mouchel, Olivier

    2008-05-28

    Traceability in the fish food sector plays an increasingly important role for consumer protection and confidence building. This is reflected by the introduction of legislation and rules covering traceability on national and international levels. Although traceability through labeling is well established and supported by respective regulations, monitoring and enforcement of these rules are still hampered by the lack of efficient diagnostic tools. We describe protocols using a direct sequencing method based on 212-274-bp diagnostic sequences derived from species-specific mitochondria DNA cytochrome b, 16S rRNA, and cytochrome oxidase subunit I sequences which can efficiently be applied to unambiguously determine even closely related fish species in processed food products labeled "anchovy". Traceability of anchovy-labeled products is supported by the public online database AnchovyID ( http://anchovyid.jrc.ec.europa.eu), which provided data obtained during our study and tools for analytical purposes.

  7. TOPICAL REVIEW: Advances in traceable nanometrology at the National Physical Laboratory†Advances in traceable nanometrology at the National Physical Laboratory

    NASA Astrophysics Data System (ADS)

    Leach, Richard; Haycocks, Jane; Jackson, Keith; Lewis, Andrew; Oldfield, Simon; Yacoot, Andrew

    2001-03-01

    The only difference between nanotechnology and many other fields of science or engineering is that of size. Control in manufacturing at the nanometre scale still requires accurate and traceable measurements whether one is attempting to machine optical quality glass or write one's company name in single atoms. A number of instruments have been developed at the National Physical Laboratory that address the measurement requirements of the nanotechnology community and provide traceability to the definition of the metre. The instruments discussed in this paper are an atomic force microscope and a surface texture measuring instrument with traceable metrology in all their operational axes, a combined optical and x-ray interferometer system that can be used to calibrate displacement transducers to subnanometre accuracy and a co-ordinate measuring machine with a working volume of (50 mm)3 and 50 nm volumetric accuracy.

  8. Value-Based Requirements Traceability: Lessons Learned

    NASA Astrophysics Data System (ADS)

    Egyed, Alexander; Grünbacher, Paul; Heindl, Matthias; Biffl, Stefan

    Traceability from requirements to code is mandated by numerous software development standards. These standards, however, are not explicit about the appropriate level of quality of trace links. From a technical perspective, trace quality should meet the needs of the intended trace utilizations. Unfortunately, long-term trace utilizations are typically unknown at the time of trace acquisition which represents a dilemma for many companies. This chapter suggests ways to balance the cost and benefits of requirements traceability. We present data from three case studies demonstrating that trace acquisition requires broad coverage but can tolerate imprecision. With this trade-off our lessons learned suggest a traceability strategy that (1) provides trace links more quickly, (2) refines trace links according to user-defined value considerations, and (3) supports the later refinement of trace links in case the initial value consideration has changed over time. The scope of our work considers the entire life cycle of traceability instead of just the creation of trace links.

  9. RELAP-7 Code Assessment Plan and Requirement Traceability Matrix

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yoo, Junsoo; Choi, Yong-joon; Smith, Curtis L.

    2016-10-01

    The RELAP-7, a safety analysis code for nuclear reactor system, is under development at Idaho National Laboratory (INL). Overall, the code development is directed towards leveraging the advancements in computer science technology, numerical solution methods and physical models over the last decades. Recently, INL has also been putting an effort to establish the code assessment plan, which aims to ensure an improved final product quality through the RELAP-7 development process. The ultimate goal of this plan is to propose a suitable way to systematically assess the wide range of software requirements for RELAP-7, including the software design, user interface, andmore » technical requirements, etc. To this end, we first survey the literature (i.e., international/domestic reports, research articles) addressing the desirable features generally required for advanced nuclear system safety analysis codes. In addition, the V&V (verification and validation) efforts as well as the legacy issues of several recently-developed codes (e.g., RELAP5-3D, TRACE V5.0) are investigated. Lastly, this paper outlines the Requirement Traceability Matrix (RTM) for RELAP-7 which can be used to systematically evaluate and identify the code development process and its present capability.« less

  10. On-orbit Metrology and Calibration Requirements for Space Station Activities Definition Study

    NASA Technical Reports Server (NTRS)

    Cotty, G. M.; Ranganathan, B. N.; Sorrell, A. L.

    1989-01-01

    The Space Station is the focal point for the commercial development of space. The long term routine operation of the Space Station and the conduct of future commercial activities suggests the need for in-space metrology capabilities analogous when possible to those on-Earth. The ability to perform periodic calibrations and measurements with proper traceability is imperative for the routine operation of the Space Station. An initial review, however, indicated a paucity of data related to metrology and calibration requirements for in-space operations. This condition probably exists because of the highly developmental aspect of space activities to date, their short duration, and nonroutine nature. The on-orbit metrology and calibration needs of the Space Station were examined and assessed. In order to achieve this goal, the following tasks were performed: an up-to-date literature review; identification of on-orbit calibration techniques; identification of sensor calibration requirements; identification of calibration equipment requirements; definition of traceability requirements; preparation of technology development plans; and preparation of the final report. Significant information and major highlights pertaining to each task is presented. In addition, some general (generic) conclusions/observations and recommendations that are pertinent to the overall in-space metrology and calibration activities are presented.

  11. Development of a metrological atomic force microscope with a tip-tilting mechanism for 3D nanometrology

    NASA Astrophysics Data System (ADS)

    Kizu, Ryosuke; Misumi, Ichiko; Hirai, Akiko; Kinoshita, Kazuto; Gonda, Satoshi

    2018-07-01

    A metrological atomic force microscope with a tip-tilting mechanism (tilting-mAFM) has been developed to expand the capabilities of 3D nanometrology, particularly for high-resolution topography measurements at the surfaces of vertical sidewalls and for traceable measurements of nanodevice linewidth. In the tilting-mAFM, the probe tip is tilted from vertical to 16° at maximum such that the probe tip can touch and trace the vertical sidewall of a nanometer-scale structure; the probe of a conventional atomic force microscope cannot reach the vertical surface because of its finite cone angle. Probe displacement is monitored in three axes by using high-resolution laser interferometry, which is traceable to the SI unit of length. A central-symmetric 3D scanner with a parallel spring structure allows probe scanning with extremely low interaxial crosstalk. A unique technique for scanning vertical sidewalls was also developed and applied. The experimental results indicated high repeatability in the scanned profiles and sidewall angle measurements. Moreover, the 3D measurement of a line pattern was demonstrated, and the data from both sidewalls were successfully stitched together with subnanometer accuracy. Finally, the critical dimension of the line pattern was obtained.

  12. On the traceability of gaseous reference materials

    NASA Astrophysics Data System (ADS)

    Brown, Richard J. C.; Brewer, Paul J.; Harris, Peter M.; Davidson, Stuart; van der Veen, Adriaan M. H.; Ent, Hugo

    2017-06-01

    The complex and multi-parameter nature of chemical composition measurement means that establishing traceability is a challenging task. As a result incorrect interpretations about the origin of the metrological traceability of chemical measurement results can occur. This discussion paper examines why this is the case by scrutinising the peculiarities of the gas metrology area. It considers in particular: primary methods, dissemination of metrological traceability and the role of documentary standards and accreditation bodies in promulgating best practice. There is also a discussion of documentary standards relevant to the NMI and reference material producer community which need clarification, and the impact which key stakeholders in the quality infrastructure can bring to these issues.

  13. CCQM-K140: carbon stable isotope ratio delta values in honey

    NASA Astrophysics Data System (ADS)

    Dunn, P. J. H.; Goenaga-Infante, H.; Goren, A. C.; Şimşek, A.; Bilsel, M.; Ogrinc, N.; Armishaw, P.; Hai, L.

    2017-01-01

    As there can be small but measureable differences in isotope ratios between different sources of the same element/compound/material, isotope ratio measurements are applied in a number of different fields including archaeology, environmental science, geochemistry, forensic science and ecology. Isotope ratios for the light elements (H, C, N, O and S) are typically reported as δ-values which are isotope ratios expressed relative to an internationally agreed standard (this standard is the zero-point on the scale), although absolute isotope ratios which are traceable to the SI have also been reported. The IAWG has been granted a traceability exception for the use of arbitrary delta scales until SI traceability can be established at the required level of uncertainty but this goal is some years away. While the CCQM IAWG has previously organised several pilot studies on isotope ratio determination (CCQM-P75: Stable isotope delta values in methionine, 2006; CCQM-P105: Sr isotope ratios in wine, 2008; CCQM-K98: Pb isotope ratios in bronze with additional delta values in CCQM-P134, 2011), it has been a number of years since delta values of light elements have been considered and there has been no key comparison (KC). Therefore, the IAWG has included the need for a KC (CCQM-K140) based on an arbitrary delta scale in its program to support ongoing requirements to demonstrate core capabilities as well as specific claims of measurement capability (CMCs) in this area. The performance of all five of the CCQM-K140 participants was very good, illustrating their ability to obtain accurate results for carbon isotope ratios, within the calibration range afforded by internationally agreed reference materials (δ13CVPDB-LSVEC between -47.32 % and +535.3 %) with measurement uncertainties of between 0.08 and 0.28 %. This was despite the fact that no two participants used exactly the same approach in terms of instrumentation or data treatment. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. Simulation and Measurement of Absorbed Dose from 137 Cs Gammas Using a Si Timepix Detector

    NASA Technical Reports Server (NTRS)

    Stoffle, Nicholas; Pinsky, Lawrence; Empl, Anton; Semones, Edward

    2011-01-01

    The TimePix readout chip is a hybrid pixel detector with over 65k independent pixel elements. Each pixel contains its own circuitry for charge collection, counting logic, and readout. When coupled with a Silicon detector layer, the Timepix chip is capable of measuring the charge, and thus energy, deposited in the Silicon. Measurements using a NIST traceable 137Cs gamma source have been made at Johnson Space Center using such a Si Timepix detector, and this data is compared to simulations of energy deposition in the Si layer carried out using FLUKA.

  15. Construction of Traceability System for Quality Safety of Cereal and Oil Products

    NASA Astrophysics Data System (ADS)

    Zheng, Huoguo; Liu, Shihong; Meng, Hong; Hu, Haiyan

    After several significant food safety incident, global food industry and governments in many countries are putting increasing emphasis on establishment of food traceability systems. Food traceability has become an effective way in food quality and safety management. The traceability system for quality safety of cereal and oil products was designed and implemented with HACCP and FMECA method, encoding, information processing, and hardware R&D technology etc, according to the whole supply chain of cereal and oil products. Results indicated that the system provide not only the management in origin, processing, circulating and consuming for enterprise, but also tracing service for customers and supervisor by means of telephone, internet, SMS, touch machine and mobile terminal.

  16. Efficacy of predictive wavefront control for compensating aero-optical aberrations

    NASA Astrophysics Data System (ADS)

    Goorskey, David J.; Schmidt, Jason; Whiteley, Matthew R.

    2013-07-01

    Imaging and laser beam propagation from airborne platforms are degraded by dynamic aberrations due to air flow around the aircraft, aero-mechanical distortions and jitter, and free atmospheric turbulence. For certain applications, like dim-object imaging, free-space optical communications, and laser weapons, adaptive optics (AO) is necessary to compensate for the aberrations in real time. Aero-optical flow is a particularly interesting source of aberrations whose flowing structures can be exploited by adaptive and predictive AO controllers, thereby realizing significant performance gains. We analyze dynamic aero-optical wavefronts to determine the pointing angles at which predictive wavefront control is more effective than conventional, fixed-gain, linear-filter control. It was found that properties of the spatial decompositions and temporal statistics of the wavefronts are directly traceable to specific features in the air flow. Furthermore, the aero-optical wavefront aberrations at the side- and aft-looking angles were the most severe, but they also benefited the most from predictive AO.

  17. Comparative analysis for evaluating the traceability of interventional devices using blood vessel phantom models made of PVA-H or silicone.

    PubMed

    Yu, Chang-Ho; Kwon, Tae-Kyu; Park, Chan Hee; Ohta, Makoto; Kim, Sung Hoon

    2015-01-01

    In this paper, we investigated the parameters with effective traceability to assess the mechanical properties of interventional devices. In our evaluation system, a box-shaped poly (vinyl alcohol) hydrogel (PVA-H) and silicone were prepared with realistic geometry, and the measurement and evaluation of traceability were carried out on devices using load hand force. The phantom models had a total of five curve pathways to reach the aneurysm sac. Traceability depends on the performance of the interventional devices in order to pass through the curved part of the model simulation track. The traceability of the guide wire was found to be much better than that of the balloon and stent loading catheter, as it reached the aneurysm sac in both phantom models. Observation using the video record is another advantage of our system, because the high transparency of the materials with silicone and PVA-H can allow visualization of the inside of an artery.

  18. A Traceable Ground to On-Orbit Radiometric Calibration System for the Solar Reflective Wavelength Region

    NASA Technical Reports Server (NTRS)

    Heath, Donald F.; Georgiev, Georgi

    2012-01-01

    This paper describes the combination of a Mie scattering spectral BSDF and BTDF albedo standard whose calibration is traceable to the NIST SIRCUS Facility or the NIST STARR II Facility. The Space-based Calibration Transfer Spectroradiometer (SCATS) sensor uses a simple, invariant optical configuration and dedicated narrow band spectral channel modules to provide very accurate, polarization-insensitive, stable measurements of earth albedo and lunar disk albedo. Optical degradation effects on calibration stability are eliminated through use of a common optical system for observations of the Sun, Earth, and Moon. The measurements from space would be traceable to SI units through preflight calibrations of radiance and irradiance at NIST's SIRCUS facility and the invariant optical system used in the sensor. Simultaneous measurements are made in multiple spectral channels covering the solar reflective wavelength range of 300 nm to 2.4 microns. The large dynamic range of signals is handled by use of single-element, highly-linear detectors, stable discrete electronic components, and a non imaging optical configuration. Up to 19 spectral modules can be mounted on a single-axis drive to give direct pointing at the Earth and at least once per orbit view of the Sun and Moon. By observing the Sun on every orbit, the most stringent stability requirements of the system are limited to short time periods. The invariant optical system for both radiance and irradiance measurements also give excellent transfer to-orbit SI traceability. Emerging instrumental requirements for remotely sensing tropospheric trace species have led to a rethinking by some of the paradigm for Systeme International d'Unites (SI) traceability of the spectral irradiance and radiance radiometric calibrations to spectral albedo (sr(exp -1)) which is not a SI unit. In the solar reflective wavelength region the spectral albedo calibrations are tied often to either the spectral albedo of a solar diffuser or the Moon. This new type of Mie scattering diffuser (MSD) is capable of withstanding high temperatures, and is more Lambertian than Spectralon(tm). It has the potential of covering the entire solar reflective wavelength region. Laboratory measurements have shown that the specular reflectance component is negligible, and indicate that internal absorption by multiple scattering is small. This MSD, a true volume diffuser, exhibits a high degree of radiometric stability which suggests that measurements at the National Institute of Standards and Technology (NIST) could provide a spectral albedo standard. Measurements have been made of its radiometric stability under a simulated space environment of high energy gamma rays, high energy protons, and UV radiation from ambient down to the vacuum ultraviolet H Lyman alpha at 121.6 nm for its eventual use in space as a solar diffuser.

  19. Tracking Online Trails

    NASA Astrophysics Data System (ADS)

    Qi, Man; Edgar-Nevill, Denis; Wang, Yongquan; Xu, Rongsheng

    Traceability is a key to the investigation of the internet criminal and a cornerstone of internet research. It is impossible to prevent all internet misuse but may be possible to identify and trace the users, and then take appropriate action. This paper presents the value of traceability within the email/-newsposting utilities, the technologies being using to hide identities, the difficulties in locating the traceable data and the challenges in tracking online trails.

  20. Management traceability information system for the food supply chain

    NASA Astrophysics Data System (ADS)

    Bendriss, S.; Benabdelhafid, A.; Boukachour, J.

    2008-06-01

    For a long time, the traceability was applied only for management reasons, but with the advent of new communication and information technologies more and more used in the logistic medium, the notion of the traceability became new extensive to meet the new market needs in term of information by ensuring accessibility the data characteristic or been dependent on the product throughout its life cycle. On the basis of this postulate, we tried to raise some questions of research, beginning by the presentation of the progress achieved, assumptions and objective relating to the traceability, in the second time we mentioned principal work by showing how evolved the scientific question especially the information systems integrating the traceability were developed very little in the literature. Based on what was developed in the first part, we present our generic modeling approach of communicating product "smart object", able to take into account the various essential elements for its traceability: the product in its various states, various operations carried out on the product, resources used, its localization, and interactions between the product and its environment carried out on the basis of whole of service. In order to validate our generic modeling, a case of study representing an application in a context of food industry is presented.

  1. Tissue allograft coding and traceability in USM Tissue Bank, Malaysia.

    PubMed

    Sheikh Ab Hamid, Suzina; Abd Rahman, Muhamad Nor Firdaus

    2010-11-01

    In Malaysia, tissue banking activities began in Universiti Sains Malaysia (USM) Tissue Bank in early 1990s. Since then a few other bone banks have been set up in other government hospitals and institutions. However, these banks are not governed by the national authority. In addition there is no requirement set by the national regulatory authority on coding and traceability for donated human tissues for transplantation. Hence, USM Tissue Bank has taken the initiatives to adopt a system that enables the traceability of tissues between the donor, the processed tissue and the recipient based on other international standards for tissue banks. The traceability trail has been effective and the bank is certified compliance to the international standard ISO 9001:2008.

  2. TF4SM: A Framework for Developing Traceability Solutions in Small Manufacturing Companies

    PubMed Central

    Bordel Sánchez, Borja; Alcarria, Ramón; Martín, Diego; Robles, Tomás

    2015-01-01

    Nowadays, manufacturing processes have become highly complex. Besides, more and more, governmental institutions require companies to implement systems to trace a product’s life (especially for foods, clinical materials or similar items). In this paper, we propose a new framework, based on cyber-physical systems, for developing traceability systems in small manufacturing companies (which because of their size cannot implement other commercial products). We propose a general theoretical framework, study the requirements of these companies in relation to traceability systems, propose a reference architecture based on both previous elements and build the first minimum functional prototype, to compare our solution to a traditional tag-based traceability system. Results show that our system reduces the number of inefficiencies and reaction time. PMID:26610509

  3. TF4SM: A Framework for Developing Traceability Solutions in Small Manufacturing Companies.

    PubMed

    Bordel Sánchez, Borja; Alcarria, Ramón; Martín, Diego; Robles, Tomás

    2015-11-20

    Nowadays, manufacturing processes have become highly complex. Besides, more and more, governmental institutions require companies to implement systems to trace a product's life (especially for foods, clinical materials or similar items). In this paper, we propose a new framework, based on cyber-physical systems, for developing traceability systems in small manufacturing companies (which because of their size cannot implement other commercial products). We propose a general theoretical framework, study the requirements of these companies in relation to traceability systems, propose a reference architecture based on both previous elements and build the first minimum functional prototype, to compare our solution to a traditional tag-based traceability system. Results show that our system reduces the number of inefficiencies and reaction time.

  4. Hydrothermal synthesis of nitrogen-doped carbon dots with real-time live-cell imaging and blood-brain barrier penetration capabilities.

    PubMed

    Lu, Shousi; Guo, Shanshan; Xu, Pingxiang; Li, Xiaorong; Zhao, Yuming; Gu, Wei; Xue, Ming

    Nitrogen-doped carbon dots (N-CDs) were synthesized using a one-pot hydrothermal treatment with citric acid in the presence of polyethylenimine. Transmission electron microscopy analysis revealed that the N-CDs were monodispersed and quasi-spherical with an average size of ~2.6 nm. Under ultraviolet irradiation the N-CDs emitted a strong blue luminescence with a quantum yield as high as 51%. Moreover, the N-CDs exhibited a negligible cytotoxicity and could be applied as efficient nanoprobes for real-time imaging of live cells. In addition, the ability of the N-CDs to cross the blood-brain barrier (BBB) in a concentration-dependent manner was demonstrated using an in vitro BBB model. Therefore, these PEI-passivated N-CDs with real-time live-cell imaging and BBB-penetration capabilities hold promise for traceable drug delivery to the brain.

  5. Hydrothermal synthesis of nitrogen-doped carbon dots with real-time live-cell imaging and blood–brain barrier penetration capabilities

    PubMed Central

    Lu, Shousi; Guo, Shanshan; Xu, Pingxiang; Li, Xiaorong; Zhao, Yuming; Gu, Wei; Xue, Ming

    2016-01-01

    Nitrogen-doped carbon dots (N-CDs) were synthesized using a one-pot hydrothermal treatment with citric acid in the presence of polyethylenimine. Transmission electron microscopy analysis revealed that the N-CDs were monodispersed and quasi-spherical with an average size of ~2.6 nm. Under ultraviolet irradiation the N-CDs emitted a strong blue luminescence with a quantum yield as high as 51%. Moreover, the N-CDs exhibited a negligible cytotoxicity and could be applied as efficient nanoprobes for real-time imaging of live cells. In addition, the ability of the N-CDs to cross the blood–brain barrier (BBB) in a concentration-dependent manner was demonstrated using an in vitro BBB model. Therefore, these PEI-passivated N-CDs with real-time live-cell imaging and BBB-penetration capabilities hold promise for traceable drug delivery to the brain. PMID:27932880

  6. All chain Loran-C time synchronization

    NASA Technical Reports Server (NTRS)

    Sherman, H. T.

    1973-01-01

    A program is in progress to implement coordinated universal time (UTC) synchronization on all Loran-C transmissions. The present capability is limited to five Loran-C chains in which the tolerance is twenty-five microseconds with respect to UTC. Upon completion of the program, the transmissions of all Loran-C chains will be maintained within five microseconds of UTC. The improvement plan consists of equipping selected Loran-C transmitting stations for greater precision of frequency standard adjustment and improved monitoring capability. External time monitor stations will utilize television time transfer techniques with nearby SATCOM terminals where practicable, thus providing the requisite traceability to the Naval Observatory. The monitor equipment groups and the interrelationships with the ground station equipment are discussed. After a brief review of control doctrine, forth-coming improvements to transmitting stations and how the time monitor and navigation equipments will complement each other resulting in improved service to all users of the Loran-C system are described.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gröbner, Julian; Reda, Ibrahim; Wacker, Stefan

    Atmospheric longwave irradiance is currently not metrologically traceable. Traceability requires formal comparisons in the framwork of the CIPM MRA. A task team on Radiation has been created by the WMO to address these issues.

  8. Results of Absolute Cavity Pyrgeometer and Infrared Integrating Sphere Comparisons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reda, Ibrahim M; Sengupta, Manajit; Dooraghi, Michael R

    Accurate and traceable atmospheric longwave irradiance measurements are required for understanding radiative impacts on the Earth's energy budget. The standard to which pyrgeometers are traceable is the interim World Infrared Standard Group (WISG), maintained in the Physikalisch-Meteorologisches Observatorium Davos (PMOD). The WISG consists of four pyrgeometers that were calibrated using Rolf Philipona's Absolute Sky-scanning Radiometer [1]. The Atmospheric Radiation Measurement (ARM) facility has recently adopted the WISG to maintain the traceability of the calibrations of all Eppley precision infrared radiometer (PIR) pyrgeometers. Subsequently, Julian Grobner [2] developed the infrared interferometer spectrometer and radiometer (IRIS) radiometer, and Ibrahim Reda [3] developedmore » the absolute cavity pyrgeometer (ACP). The ACP and IRIS were developed to establish a world reference for calibrating pyrgeometers with traceability to the International System of Units (SI). The two radiometers are unwindowed with negligible spectral dependence, and they are traceable to SI units through the temperature scale (ITS-90). The two instruments were compared directly to the WISG three times at PMOD and twice at the Southern Great Plains (SGP) facility to WISG-traceable pyrgeometers. The ACP and IRIS agreed within +/- 1 W/m2 to +/- 3 W/m2 in all comparisons, whereas the WISG references exhibit a 2-5 Wm2 low bias compared to the ACP/IRIS average, depending on the water vapor column, as noted in Grobner et al. [4]. Consequently, a case for changing the current WISG has been made by Grobner and Reda. However, during the five comparisons the column water vapor exceeded 8 mm. Therefore, it is recommended that more ACP and IRIS comparisons should be held under different environmental conditions and water vapor column content to better establish the traceability of these instruments to SI with established uncertainty.« less

  9. Flow visualization of a non-contact transport device by Coanda effect

    NASA Astrophysics Data System (ADS)

    Iki, Norihiko; Abe, Hiroyuki; Okada, Takashi

    2014-08-01

    AIST proposes new technology of non-contact transport device utilizing Coanda effect. A proposed non-contact transport device has a cylindrical body and circular slit for air. The air flow around non-contact device is turbulent and its flow pattern depends on the injection condition. Therefore we tried visualization of the air flow around non -contact device as the first step of PIV measurement. Several tracer particles were tried such as TiO2 particles, water droplets, potatoes starch, rice starch, corn starch. Hot-wire anemometer is employed to velocity measurement. TiO2 particles deposit inside of a slit and clogging of a slit occurs frequently. Potato starch particles do not clog a slit but they are too heavy to trace slow flow area. Water droplets by ultrasonic atomization also deposit inside of slit but they are useful to visualize flow pattern around a non-contact transport device by being supplied from circumference. Coanda effect of proposed non-contact transport device was confirmed and injected air flow pattern switches by a work. Air flow around non-contact trance port device is turbulent and its velocity range is wide. Therefore flow measurement by tracer part icle has traceability issue. Suitable tracer and exposure condition depends on target area.

  10. a Review on Legal Traceability of Gnss Measurements in the Malaysian Cadastral Practice

    NASA Astrophysics Data System (ADS)

    Gill, J.; Shariff, N. S.; Omar, K. M.; Din, A. H. M.; Amin, Z. M.

    2016-09-01

    As the dependency on Global Navigation Satellite System (GNSS) in surveying has been growing over the years, the need for legal traceability of GNSS measurements has become a significant matter. In Malaysia, with the advent of the Malaysia Real-time Kinematic Network (MyRTKnet), GNSS surveying has revolutionised land survey and mapping. Correspondingly, the Department of Survey and Mapping Malaysia (DSMM) amended and published standard regulations and guidelines concerning cadastral survey, i.e., Cadastral Survey Regulations 2009, to include GNSS measurements. However, these regulations and guidelines has not comprehensively incorporated legal traceability of GNSS measurements; which is a prerequisite for cadastral surveys as it requires reliable and conclusive evidence for issues such as boundary disputes. The first objective of this paper is to review and discuss the legal traceability of GNSS measurements. Secondly, it will highlight the current practice and issues, i.e., with regard to legal traceability, within the present Malaysian cadastral regulation and guidelines, in relation to the prevalently adopted Network RTK (N-RTK) technique, GNSS instrument calibrations, and reference stations' accuracy. Lastly, a rudimentary best practice guideline for GNSS surveying in cadastral survey for Malaysia is proposed. It is expected that this paper will contribute to the implementation of a best practice guideline, which is inclusive of legal traceability of GNSS measurements, for the Malaysian cadastral practice.

  11. Bio-markers: traceability in food safety issues.

    PubMed

    Raspor, Peter

    2005-01-01

    Research and practice are focusing on development, validation and harmonization of technologies and methodologies to ensure complete traceability process throughout the food chain. The main goals are: scale-up, implementation and validation of methods in whole food chains, assurance of authenticity, validity of labelling and application of HACCP (hazard analysis and critical control point) to the entire food chain. The current review is to sum the scientific and technological basis for ensuring complete traceability. Tracing and tracking (traceability) of foods are complex processes due to the (bio)markers, technical solutions and different circumstances in different technologies which produces various foods (processed, semi-processed, or raw). Since the food is produced for human or animal consumption we need suitable markers to be stable and traceable all along the production chain. Specific biomarkers can have a function in technology and in nutrition. Such approach would make this development faster and more comprehensive and would make possible that food effect could be monitored with same set of biomarkers in consumer. This would help to develop and implement food safety standards that would be based on real physiological function of particular food component.

  12. Molecular traceability of beef from synthetic Mexican bovine breeds.

    PubMed

    Rodríguez-Ramírez, R; Arana, A; Alfonso, L; González-Córdova, A F; Torrescano, G; Guerrero Legarreta, I; Vallejo-Cordoba, B

    2011-10-06

    Traceability ensures a link between carcass, quarters or cuts of beef and the individual animal or the group of animals from which they are derived. Meat traceability is an essential tool for successful identification and recall of contaminated products from the market during a food crisis. Meat traceability is also extremely important for protection and value enhancement of good-quality brands. Molecular meat traceability would allow verification of conventional methods used for beef tracing in synthetic Mexican bovine breeds. We evaluated a set of 11 microsatellites for their ability to identify animals belonging to these synthetic breeds, Brangus and Charolais/Brahman (78 animals). Seven microsatellite markers allowed sample discrimination with a match probability, defined as the probability of finding two individuals sharing by chance the same genotypic profile, of 10(-8). The practical application of the marker set was evaluated by testing eight samples from carcasses and pieces of meat at the slaughterhouse and at the point of sale. The DNA profiles of the two samples obtained at these two different points in the production-commercialization chain always proved that they came from the same animal.

  13. Seafood traceability: current needs, available tools, and biotechnological challenges for origin certification.

    PubMed

    Leal, Miguel Costa; Pimentel, Tânia; Ricardo, Fernando; Rosa, Rui; Calado, Ricardo

    2015-06-01

    Market globalization and recurring food safety alerts have resulted in a growing consumer awareness of the need for food traceability. This is particularly relevant for seafood due to its perishable nature and importance as a key protein source for the population of the world. Here, we provide an overview of the current needs for seafood origin traceability, along with the limitations and challenges for its implementation. We focus on geochemical, biochemical, and molecular tools and how they should be optimized to be implemented globally and to address our societal needs. We suggest that seafood traceability is key to enforcing food safety regulations and fisheries control, combat fraud, and fulfill present and future expectations of conscientious producers, consumers, and authorities. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. General Framework for Animal Food Safety Traceability Using GS1 and RFID

    NASA Astrophysics Data System (ADS)

    Cao, Weizhu; Zheng, Limin; Zhu, Hong; Wu, Ping

    GS1 is global traceability standard, which is composed by the encoding system (EAN/UCC, EPC), the data carriers identified automatically (bar codes, RFID), electronic data interchange standards (EDI, XML). RFID is a non-contact, multi-objective automatic identification technique. Tracing of source food, standardization of RFID tags, sharing of dynamic data are problems to solve urgently for recent traceability systems. The paper designed general framework for animal food safety traceability using GS1 and RFID. This framework uses RFID tags encoding with EPCglobal tag data standards. Each information server has access tier, business tier and resource tier. These servers are heterogeneous and distributed, providing user access interfaces by SOAP or HTTP protocols. For sharing dynamic data, discovery service and object name service are used to locate dynamic distributed information servers.

  15. Disseminating the unit of mass from multiple primary realisations

    NASA Astrophysics Data System (ADS)

    Nielsen, Lars

    2016-12-01

    When a new definition of the kilogram has been adopted in 2018 as expected, the unit of mass will be realised by the watt balance method, the x-ray crystal density method or perhaps other primary methods still to be developed. So far, the standard uncertainties associated with the available primary methods are at least one order of magnitude larger than the standard uncertainty associated with mass comparisons using mass comparators, so differences in primary realisations of the kilogram are easily detected, whereas many National Metrology Institutes would have to increase their calibration and measurement capabilities (CMCs) if they were traceable to a single primary realisation. This paper presents a scheme for obtaining traceability to multiple primary realisations of the kilogram using a small group of stainless steel 1 kg weights, which are allowed to change their masses over time in a way known to be realistic, and which are calibrated and stored in air. An analysis of the scheme shows that if the relative standard uncertainties of future primary realisations are equal to the relative standard uncertainties of the present methods used to measure the Planck constant, the unit of mass can be disseminated with a standard uncertainty less than 0.015 mg, which matches the smallest CMCs currently claimed for the calibration of 1 kg weights.

  16. 40 CFR 1065.790 - Mass standards.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... are certified as NIST-traceable within 0.1% uncertainty. Calibration weights may be certified by any calibration lab that maintains NIST-traceability. Make sure your highest calibration weight has no greater...

  17. 40 CFR 1065.790 - Mass standards.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... are certified as NIST-traceable within 0.1% uncertainty. Calibration weights may be certified by any calibration lab that maintains NIST-traceability. Make sure your highest calibration weight has no greater...

  18. 40 CFR 1065.790 - Mass standards.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... are certified as NIST-traceable within 0.1% uncertainty. Calibration weights may be certified by any calibration lab that maintains NIST-traceability. Make sure your highest calibration weight has no greater...

  19. Establishment of Traceability of Reference Grade Hydrometers at National Physical Laboratory, India (npli)

    NASA Astrophysics Data System (ADS)

    Kumar, Anil; Kumar, Harish; Mandal, Goutam; Das, M. B.; Sharma, D. C.

    The present paper discusses the establishment of traceability of reference grade hydrometers at National Physical Laboratory, India (NPLI). The reference grade hydrometers are calibrated and traceable to the primary solid density standard. The calibration has been done according to standard procedure based on Cuckow's Method and the reference grade hydrometers calibrated covers a wide range. The uncertainty of the reference grade hydrometers has been computed and corrections are also calculated for the scale readings, at which observations are taken.

  20. 40 CFR 1065.790 - Mass standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... are certified as NIST-traceable within 0.1 % uncertainty. Calibration weights may be certified by any calibration lab that maintains NIST-traceability. Make sure your lowest calibration weight has no greater than...

  1. 40 CFR 1065.790 - Mass standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... are certified as NIST-traceable within 0.1 % uncertainty. Calibration weights may be certified by any calibration lab that maintains NIST-traceability. Make sure your lowest calibration weight has no greater than...

  2. New SI-traceable reference gas mixtures for sulfur hexafluoride (SF6) at the pmol/mol level using static and dynamic preparation methods and comparison to existing scales

    NASA Astrophysics Data System (ADS)

    Wyss, Simon A.; Guillevic, Myriam; Vicar, Martin; Nieuwenkamp, Gerard; Vollmer, Martin K.; Pascale, Céline; Reimann, Stefan; Niederhauser, Bernhard; Emmenegger, Lukas

    2017-04-01

    We developed two SI-traceable methods, using both static and dynamic preparation steps, to produce reference gas mixtures for sulfur hexafluoride (SF6) in gas cylinders at pmol/mol level. This research activity is conducted under the framework of the European EMRP HIGHGAS project, in support of the high quality measurements of this important greenhouse gas in the earth's atmosphere. In the method used by the Czech Metrology Institute (CMI) a parent mixture of SF6 in synthetic air was produced in an aluminium cylinder at VSL as a first step. This mixture was produced gravimetrically according to ISO 6142 at an amount fraction of 1 μmol/mol. In the second step this primary standard was further diluted to near-ambient amount fraction, with the use of a three-step dilution system and directly pressurised into aluminium cylinders to a pressure of 10 bars. The second method used by the Federal Institute of Metrology (METAS) has already been applied to other fluorinated gases such as HFC-125 and HFC-1234yf. In this method a highly concentrated mixture is produced by spiking a purified synthetic air (matrix gas) with SF6 from a permeation device. The mass loss of SF6 in the permeation device is observed by a magnetic suspension balance. In a second step this mixture is diluted with matrix gas to the desired concentrations. All flows are controlled with mass flow controllers. The diluted gas was transferred into Silconert2000-coated stainless steel cylinders by cryo-filling. The final gas mixtures at near-ambient amount fraction were measured on a Medusa gas chromatography-mass spectrometry system (Medusa-GC/MS) against working standards calibrated on existing scales of the Scripps Institution of Oceanography (SIO) and compared to other scales [1]. The agreement of the assigned values by the CMI and METAS, with the measured values referenced on the SIO scale was excellent. This results show that with this methods we are able to produce accurate SI-traceable gas mixtures at near-ambient amount fraction for SF6, without extensive static dilutions. [1] Benjamin R. Miller, Ray F. Weiss, Peter K. Salameh, Toste Tanhua, Brian R. Greally, Jens Mühle, Peter G. Simmonds, Anal. Chem., 2008, 80, 1536.

  3. Stennis Space Center Verification & Validation Capabilities

    NASA Technical Reports Server (NTRS)

    Pagnutti, Mary; Ryan, Robert E.; Holekamp, Kara; ONeal, Duane; Knowlton, Kelly; Ross, Kenton; Blonski, Slawomir

    2005-01-01

    Scientists within NASA s Applied Sciences Directorate have developed a well-characterized remote sensing Verification & Validation (V&V) site at the John C. Stennis Space Center (SSC). This site enables the in-flight characterization of satellite and airborne high spatial and moderate resolution remote sensing systems and their products. The smaller scale of the newer high resolution remote sensing systems allows scientists to characterize geometric, spatial, and radiometric data properties using a single V&V site. The targets and techniques used to characterize data from these newer systems can differ significantly from the techniques used to characterize data from the earlier, coarser spatial resolution systems. Scientists are also using the SSC V&V site to characterize thermal infrared systems and active lidar systems. SSC employs geodetic targets, edge targets, radiometric tarps, atmospheric monitoring equipment, and thermal calibration ponds to characterize remote sensing data products. The SSC Instrument Validation Lab is a key component of the V&V capability and is used to calibrate field instrumentation and to provide National Institute of Standards and Technology traceability. This poster presents a description of the SSC characterization capabilities and examples of calibration data.

  4. A dynamic gravimetric standard for trace water.

    PubMed

    Brewer, P J; Goody, B A; Woods, P T; Milton, M J T

    2011-10-01

    A system for generating traceable reference standards of water vapor at trace levels between 5 and 2000 nmol/mol has been developed. It can provide different amount fractions of trace water vapor by using continuous accurate measurements of mass loss from a permeation device coupled with a dilution system based on an array of critical flow orifices. An estimated relative expanded uncertainty of ±2% has been achieved for most amount fractions generated. The system has been used in an international comparison and demonstrates excellent comparability with National Metrology Institutes maintaining standards of water vapor in this range using other methods.

  5. Current Developments in Future Planetary Probe Sensors for TPS

    NASA Technical Reports Server (NTRS)

    Martinez, Ed; Venkatapathy, Ethiraj; Oishu, Tomo

    2003-01-01

    In-situ Thermal Protection System (TPS) sensors are required to provide traceability of TPS performance and sizing tools. Traceability will lead to higher fidelity design tools, which in turn will lead to lower design safety margins, and decreased heatshield mass. Decreasing TPS mass will enable certain missions that are not otherwise feasible, and directly increase science payload. NASA Ames is currently developing two flight measurements as essential to advancing the state of TPS traceability for material modeling and aerothermal simulation: heat flux and surface recession (for ablators). The heat flux gage is applicable to both ablators and non-ablators and is therefore the more generalized sensor concept of the two with wider applicability to mission scenarios. This paper describes the development of a microsensor capable of surface and in-depth temperature and heat flux measurements for TPS materials appropriate to Titan, Neptune, and Mars aerocapture, and direct entry. The thermal sensor will be monolithic solid state devices composed of thick film platinum RTD on an alumina substrate. Choice of materials and critical dimensions are used to tailor gage response, determined during calibration activities, to specific (forebody vs. aftbody) heating environments. Current design has maximum operating temperature of 1500 K, and allowable constant heat flux of q=28.7 watts per square centimeter, and time constants between 0.05 and 0.2 seconds. The catalytic and radiative response of these heat flux gages can also be changed through the use of appropriate coatings. By using several co-located gages with various surface coatings, data can be obtained to isolate surface heat flux components due to radiation, catalycity and convection. Selectivity to radiative heat flux is a useful feature even for an in-depth gage, as radiative transport may be a significant heat transport mechanism for porous TPS materials in Titan aerocapture. This paper also reports on progress to adapt a previously flown surface recession sensor, based on the Jupiter probe Galileo Analog Resistance Ablation Detector (ARAD), to appropriate aerocapture conditions.

  6. Development of Solid State Thermal Sensors for Aeroshell TPS Flight Applications

    NASA Technical Reports Server (NTRS)

    Martinez, Ed; Oishi, Tomo; Gorbonov, Sergey

    2005-01-01

    In-situ Thermal Protection System (TPS) sensors are required to provide verification by traceability of TPS performance and sizing tools. Traceability will lead to higher fidelity design tools, which in turn will lead to lower design safety margins, and decreased heatshield mass. Decreasing TPS mass will enable certain missions that are not otherwise feasible, and directly increase science payload. NASA Ames is currently developing two flight measurements as essential to advancing the state of TPS traceability for material modeling and aerothermal simulation: heat flux and surface recession (for ablators). The heat flux gage is applicable to both ablators and non-ablators and is therefore the more generalized sensor concept of the two with wider applicability to mission scenarios. This paper describes the continuing development of a thermal microsensor capable of surface and in-depth temperature and heat flux measurements for TPS materials appropriate to Titan, Neptune, and Mars aerocapture, and direct entry. The thermal sensor is a monolithic solid state device composed of thick film platinum RTD on an alumina substrate. Choice of materials and critical dimensions are used to tailor gage response, determined during calibration activities, to specific (forebody vs. aftbody) heating environments. Current design has maximum operating temperature of 1500K, and allowable constant heat flux of q=28.7 W/cm(sup 2), and time constants between 0.05 and 0.2 seconds. The catalytic and radiative response of these heat flux gages can also be changed through the use of appropriate coatings. By using several co-located gages with various surface coatings, data can be obtained to isolate surface heat flux components due to radiation, catalycity and convection. Selectivity to radiative heat flux is a useful feature even for an in-depth gage, as radiative transport may be a significant heat transport mechanism for porous TPS materials in Titan aerocapture.

  7. Traceable nanoscale measurement at NML-SIRIM

    NASA Astrophysics Data System (ADS)

    Dahlan, Ahmad M.; Abdul Hapip, A. I.

    2012-06-01

    The role of national metrology institute (NMI) has always been very crucial in national technology development. One of the key activities of the NMI is to provide traceable measurement in all parameters under the International System of Units (SI). Dimensional measurement where size and shape are two important features investigated, is one of the important area covered by NMIs. To support the national technology development, particularly in manufacturing sectors and emerging technology such nanotechnology, the National Metrology Laboratory, SIRIM Berhad (NML-SIRIM), has embarked on a project to equip Malaysia with state-of-the-art nanoscale measurement facility with the aims of providing traceability of measurement at nanoscale. This paper will look into some of the results from current activities at NML-SIRIM related to measurement at nanoscale particularly on application of atomic force microscope (AFM) and laser based sensor in dimensional measurement. Step height standards of different sizes were measured using AFM and laser-based sensors. These probes are integrated into a long-range nanoscale measuring machine traceable to the international definition of the meter thus ensuring their traceability. Consistency of results obtained by these two methods will be discussed and presented. Factors affecting their measurements as well as their related uncertainty of measurements will also be presented.

  8. EPA’s Hg Gas Traceability Approach for Source Emissions Measurement and Monitoring

    EPA Science Inventory

    Solicited presentation (special topic) at the International Conference on Mercury as a Global Pollutant on how EPA establishes the NIST traceability of reference materials used to support regulatory mercury emissions measurements.

  9. Recent advance in DNA-based traceability and authentication of livestock meat PDO and PGI products.

    PubMed

    Nicoloso, Letizia; Crepaldi, Paola; Mazza, Raffaele; Ajmone-Marsan, Paolo; Negrini, Riccardo

    2013-04-01

    This review updates the available molecular techniques and technologies and discusses how they can be used for traceability, food control and enforcement activities. The review also provides examples on how molecular techniques succeeded to trace back unknowns to their breeds of origin, to fingerprint single individuals and to generate evidence in court cases. The examples demonstrate the potential of the DNA based traceability techniques and explore possibilities for translating the next generation genomics tools into a food and feed control and enforcement framework.

  10. Deccan volcanism and K-T boundary signatures

    NASA Technical Reports Server (NTRS)

    Murali, A. V.; Schuraytz, B. C.; Parekh, P. P.

    1988-01-01

    The Deccan Traps in the Indian subcontinent represent one of the most extensive flood basalt provinces in the world. These basalts occur mainly as flat-lying, subaerially erupted tholeiitic lava flows, some of which are traceable for distances of more than 100 km. Offshore drilling and geophysical surveys indicate that a part of the Deccan subsided or was downfaulted to the west beneath the Arabian Sea. The presence of 1 to 5 m thick intertrappean sediments deposited by lakes and rivers indicates periods of quiescence between eruptions. The occurrence of numerous red bole beds among the flows suggests intense weathering of flow tops between eruptive intervals. Although the causative relationship of the Cretaceous-Tertiary (K-T) biotic extinctions to Deccan volcanism is debatable, the fact that the main Deccan eruptions straddle the K-T event appears beyond doubt from the recent Ar-40/Ar-39 ages of various Deccan flows. This temporal relationship of the K-T event with Deccan volcanism makes the petrochemical signatures of the entire Deccan sequence (basalt flows, intercalated intertrappean sediments, infratrappean Lameta beds (with dinosaur fossils), and the bole beds) pertinent to studies of the K-T event. The results of ongoing study is presented.

  11. Traceability of Biologics in The Netherlands: An Analysis of Information-Recording Systems in Clinical Practice and Spontaneous ADR Reports.

    PubMed

    Klein, Kevin; Scholl, Joep H G; Vermeer, Niels S; Broekmans, André W; Van Puijenbroek, Eugène P; De Bruin, Marie L; Stolk, Pieter

    2016-02-01

    Pharmacovigilance requirements for biologics mandate that EU Member States shall ensure that any biologic that is the subject of a suspected adverse drug reaction (ADR) is identifiable by brand name and batch number. Recent studies showed that brand name identification is well established, whereas batch numbers are (still) poorly reported. We evaluated information-recording systems and practices in the Dutch hospital setting to identify determinants for brand name and batch number recording as well as success factors and bottlenecks for traceability. We surveyed Dutch hospital pharmacists with an online questionnaire on systems and practices in hospitals for recording brand names and batch numbers. Additionally, we performed an analysis of the traceability of recombinant biologics in spontaneous ADR reports (received between 2009 and 2014) from the Netherlands Pharmacovigilance Centre Lareb. The survey showed that brand names are not routinely recorded in the clinical practice of Dutch hospitals, whereas batch numbers are poorly recorded. Seventy-six percent of the 1523 ADR reports for recombinant biologics had a traceable brand name whereas 5% of these reports contained a batch number. The results suggest a possible relationship between the availability of brand and batch number information in clinical practice and the inclusion of this information in ADR reports for biologics. The limited traceability of brand names and batch numbers in ADR reports may be primarily caused by the shortcomings in the recording of information in clinical practice. We recommend efforts to improve information-recording systems as a first step to improve the traceability of biologics in ADR reporting.

  12. Differential Laser Doppler based Non-Contact Sensor for Dimensional Inspection with Error Propagation Evaluation

    PubMed Central

    Mekid, Samir; Vacharanukul, Ketsaya

    2006-01-01

    To achieve dynamic error compensation in CNC machine tools, a non-contact laser probe capable of dimensional measurement of a workpiece while it is being machined has been developed and presented in this paper. The measurements are automatically fed back to the machine controller for intelligent error compensations. Based on a well resolved laser Doppler technique and real time data acquisition, the probe delivers a very promising dimensional accuracy at few microns over a range of 100 mm. The developed optical measuring apparatus employs a differential laser Doppler arrangement allowing acquisition of information from the workpiece surface. In addition, the measurements are traceable to standards of frequency allowing higher precision.

  13. End-to-end commissioning demonstration of the James Webb Space Telescope

    NASA Astrophysics Data System (ADS)

    Acton, D. Scott; Towell, Timothy; Schwenker, John; Shields, Duncan; Sabatke, Erin; Contos, Adam R.; Hansen, Karl; Shi, Fang; Dean, Bruce; Smith, Scott

    2007-09-01

    The one-meter Testbed Telescope (TBT) has been developed at Ball Aerospace to facilitate the design and implementation of the wavefront sensing and control (WFSC) capabilities of the James Webb Space Telescope (JWST). We have recently conducted an "end-to-end" demonstration of the flight commissioning process on the TBT. This demonstration started with the Primary Mirror (PM) segments and the Secondary Mirror (SM) in random positions, traceable to the worst-case flight deployment conditions. The commissioning process detected and corrected the deployment errors, resulting in diffraction-limited performance across the entire science FOV. This paper will describe the commissioning demonstration and the WFSC algorithms used at each step in the process.

  14. USCEA/NIST measurement assurance programs for the radiopharmaceutical and nuclear power industries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Golas, D.B.

    1993-12-31

    In cooperation with the U.S. Council for Energy Awareness (USCEA), the National Institute of Standards and Technology (NIST) supervises and administers two measurement assurance programs for radioactivity measurement traceability. One, in existence since the mid 1970s, provides traceability to suppliers of radiochemicals and radiopharmaceuticals, dose calibrators, and nuclear pharmacy services. The second program, begun in 1987, provides traceability to the nuclear power industry for utilities, source suppliers, and service laboratories. Each program is described, and the results of measurements of samples of known, but undisclosed activity, prepared at NIST and measured by the participants are presented.

  15. Lightweight approach to model traceability in a CASE tool

    NASA Astrophysics Data System (ADS)

    Vileiniskis, Tomas; Skersys, Tomas; Pavalkis, Saulius; Butleris, Rimantas; Butkiene, Rita

    2017-07-01

    A term "model-driven" is not at all a new buzzword within the ranks of system development community. Nevertheless, the ever increasing complexity of model-driven approaches keeps fueling all kinds of discussions around this paradigm and pushes researchers forward to research and develop new and more effective ways to system development. With the increasing complexity, model traceability, and model management as a whole, becomes indispensable activities of model-driven system development process. The main goal of this paper is to present a conceptual design and implementation of a practical lightweight approach to model traceability in a CASE tool.

  16. Selection and use of microsatellite markers for individual identification and meat traceability of six swine breeds in the Chinese market.

    PubMed

    Zhao, Jie; Li, Tingting; Zhu, Chao; Jiang, Xiaoling; Zhao, Yan; Xu, Zhenzhen; Yang, Shuming; Chen, Ailiang

    2018-06-01

    Meat traceability based on molecular markers is exerting a great influence on food safety and will enhance its key role in the future. This study aimed to investigate and verify the polymorphism of 23 microsatellite markers and select the most suitable markers for individual identification and meat traceability of six swine breeds in the Chinese market. The mean polymorphism information content value of these 23 loci was 0.7851, and each locus exhibited high polymorphism in the pooled population. There were 10 loci showing good polymorphism in each breed, namely, Sw632, S0155, Sw2406, Sw830, Sw2525, Sw72, Sw2448, Sw911, Sw122 and CGA. When six highly polymorphic loci were combined, the match probability value for two random individual genotypes among the pig breeds (Beijing Black, Sanyuan and Taihu) was lower than 1.151 E-06. An increasing number of loci indicated a gradually decreasing match probability value and therefore enhanced traceability accuracy. The validation results of tracing 18 blood and corresponding meat samples based on five highly polymorphic loci (Sw2525, S0005, Sw0107, Sw911 and Sw857) were successful, with 100% conformation probability, which provided a foundation for establishing a traceability system for pork in the Chinese market.

  17. Feature Fusion of ICP-AES, UV-Vis and FT-MIR for Origin Traceability of Boletus edulis Mushrooms in Combination with Chemometrics.

    PubMed

    Qi, Luming; Liu, Honggao; Li, Jieqing; Li, Tao; Wang, Yuanzhong

    2018-01-15

    Origin traceability is an important step to control the nutritional and pharmacological quality of food products. Boletus edulis mushroom is a well-known food resource in the world. Its nutritional and medicinal properties are drastically varied depending on geographical origins. In this study, three sensor systems (inductively coupled plasma atomic emission spectrophotometer (ICP-AES), ultraviolet-visible (UV-Vis) and Fourier transform mid-infrared spectroscopy (FT-MIR)) were applied for the origin traceability of 192 mushroom samples (caps and stipes) in combination with chemometrics. The difference between cap and stipe was clearly illustrated based on a single sensor technique, respectively. Feature variables from three instruments were used for origin traceability. Two supervised classification methods, partial least square discriminant analysis (FLS-DA) and grid search support vector machine (GS-SVM), were applied to develop mathematical models. Two steps (internal cross-validation and external prediction for unknown samples) were used to evaluate the performance of a classification model. The result is satisfactory with high accuracies ranging from 90.625% to 100%. These models also have an excellent generalization ability with the optimal parameters. Based on the combination of three sensory systems, our study provides a multi-sensory and comprehensive origin traceability of B. edulis mushrooms.

  18. Feature Fusion of ICP-AES, UV-Vis and FT-MIR for Origin Traceability of Boletus edulis Mushrooms in Combination with Chemometrics

    PubMed Central

    Qi, Luming; Liu, Honggao; Li, Jieqing; Li, Tao

    2018-01-01

    Origin traceability is an important step to control the nutritional and pharmacological quality of food products. Boletus edulis mushroom is a well-known food resource in the world. Its nutritional and medicinal properties are drastically varied depending on geographical origins. In this study, three sensor systems (inductively coupled plasma atomic emission spectrophotometer (ICP-AES), ultraviolet-visible (UV-Vis) and Fourier transform mid-infrared spectroscopy (FT-MIR)) were applied for the origin traceability of 184 mushroom samples (caps and stipes) in combination with chemometrics. The difference between cap and stipe was clearly illustrated based on a single sensor technique, respectively. Feature variables from three instruments were used for origin traceability. Two supervised classification methods, partial least square discriminant analysis (FLS-DA) and grid search support vector machine (GS-SVM), were applied to develop mathematical models. Two steps (internal cross-validation and external prediction for unknown samples) were used to evaluate the performance of a classification model. The result is satisfactory with high accuracies ranging from 90.625% to 100%. These models also have an excellent generalization ability with the optimal parameters. Based on the combination of three sensory systems, our study provides a multi-sensory and comprehensive origin traceability of B. edulis mushrooms. PMID:29342969

  19. Los Angeles congestion reduction demonstration (Metro ExpressLanes) program. National evaluation : exogenous factors test plan.

    DOT National Transportation Integrated Search

    1999-12-01

    The Traceability document consists of brief introductory material and a series of appended Trace Tables. These tables provide complete traceability of ITS User Service Requirements (USR) to elements of the National ITS Architecture. Additional Trace ...

  20. Controlling protected designation of origin of wine by Raman spectroscopy.

    PubMed

    Mandrile, Luisa; Zeppa, Giuseppe; Giovannozzi, Andrea Mario; Rossi, Andrea Mario

    2016-11-15

    In this paper, a Fourier Transform Raman spectroscopy method, to authenticate the provenience of wine, for food traceability applications was developed. In particular, due to the specific chemical fingerprint of the Raman spectrum, it was possible to discriminate different wines produced in the Piedmont area (North West Italy) in accordance with i) grape varieties, ii) production area and iii) ageing time. In order to create a consistent training set, more than 300 samples from tens of different producers were analyzed, and a chemometric treatment of raw spectra was applied. A discriminant analysis method was employed in the classification procedures, providing a classification capability (percentage of correct answers) of 90% for validation of grape analysis and geographical area provenance, and a classification capability of 84% for ageing time classification. The present methodology was applied successfully to raw materials without any preliminary treatment of the sample, providing a response in a very short time. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. System description for DART (Decision Analysis for Remediation Technologies)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nonte, J.; Bolander, T.; Nickelson, D.

    1997-09-01

    DART is a computer aided system populated with influence models to determine quantitative benefits derived by matching requirements and technologies. The DART database is populated with data from over 900 DOE sites from 10 Field Offices. These sites are either source terms, such as buried waste pits, or soil or groundwater contaminated plumes. The data, traceable to published documents, consists of site-specific data (contaminants, area, volume, depth, size, remedial action dates, site preferred remedial option), problems (e.g., offsite contaminant plume), and Site Technology Coordinating Group (STCG) need statements (also contained in the Ten-Year Plan). DART uses this data to calculatemore » and derive site priorities, risk rankings, and site specific technology requirements. DART is also populated with over 900 industry and DOE SCFA technologies. Technology capabilities can be used to match technologies to waste sites based on the technology`s capability to meet site requirements and constraints. Queries may be used to access, sort, roll-up, and rank site data. Data roll-ups may be graphically displayed.« less

  2. Initial design and performance of the near surface unmanned aircraft system sensor suite in support of the GOES-R field campaign

    NASA Astrophysics Data System (ADS)

    Pearlman, Aaron J.; Padula, Francis; Shao, Xi; Cao, Changyong; Goodman, Steven J.

    2016-09-01

    One of the main objectives of the Geostationary Operational Environmental Satellite R-Series (GOES-R) field campaign is to validate the SI traceability of the Advanced Baseline Imager. The campaign plans include a feasibility demonstration study for new near surface unmanned aircraft system (UAS) measurement capability that is being developed to meet the challenges of validating geostationary sensors. We report our progress in developing our initial systems by presenting the design and preliminary characterization results of the sensor suite. The design takes advantage of off-the-shelf technologies and fiber-based optical components to make hemispheric directional measurements from a UAS. The characterization results - including laboratory measurements of temperature effects and polarization sensitivity - are used to refine the radiometric uncertainty budget towards meeting the validation objectives for the campaign. These systems will foster improved validation capabilities for the GOES-R field campaign and other next generation satellite systems.

  3. Blockchain protocols in clinical trials: Transparency and traceability of consent.

    PubMed

    Benchoufi, Mehdi; Porcher, Raphael; Ravaud, Philippe

    2017-01-01

    Clinical trial consent for protocols and their revisions should be transparent for patients and traceable for stakeholders. Our goal is to implement a process allowing for collection of patients' informed consent, which is bound to protocol revisions, storing and tracking the consent in a secure, unfalsifiable and publicly verifiable way, and enabling the sharing of this information in real time. For that, we build a consent workflow using a trending technology called Blockchain. This is a distributed technology that brings a built-in layer of transparency and traceability. From a more general and prospective point of view, we believe Blockchain technology brings a paradigmatical shift to the entire clinical research field. We designed a Proof-of-Concept protocol consisting of time-stamping each step of the patient's consent collection using Blockchain, thus archiving and historicising the consent through cryptographic validation in a securely unfalsifiable and transparent way. For each protocol revision, consent was sought again.  We obtained a single document, in an open format, that accounted for the whole consent collection process: a time-stamped consent status regarding each version of the protocol. This document cannot be corrupted and can be checked on any dedicated public website. It should be considered a robust proof of data. However, in a live clinical trial, the authentication system should be strengthened to remove the need for third parties, here trial stakeholders, and give participative control to the peer users. In the future, the complex data flow of a clinical trial could be tracked by using Blockchain, which core functionality, named Smart Contract, could help prevent clinical trial events not occurring in the correct chronological order, for example including patients before they consented or analysing case report form data before freezing the database. Globally, Blockchain could help with reliability, security, transparency and could be a consistent step toward reproducibility.

  4. Blockchain protocols in clinical trials: Transparency and traceability of consent

    PubMed Central

    Benchoufi, Mehdi; Porcher, Raphael; Ravaud, Philippe

    2018-01-01

    Clinical trial consent for protocols and their revisions should be transparent for patients and traceable for stakeholders. Our goal is to implement a process allowing for collection of patients’ informed consent, which is bound to protocol revisions, storing and tracking the consent in a secure, unfalsifiable and publicly verifiable way, and enabling the sharing of this information in real time. For that, we build a consent workflow using a trending technology called Blockchain. This is a distributed technology that brings a built-in layer of transparency and traceability. From a more general and prospective point of view, we believe Blockchain technology brings a paradigmatical shift to the entire clinical research field. We designed a Proof-of-Concept protocol consisting of time-stamping each step of the patient’s consent collection using Blockchain, thus archiving and historicising the consent through cryptographic validation in a securely unfalsifiable and transparent way. For each protocol revision, consent was sought again.  We obtained a single document, in an open format, that accounted for the whole consent collection process: a time-stamped consent status regarding each version of the protocol. This document cannot be corrupted and can be checked on any dedicated public website. It should be considered a robust proof of data. However, in a live clinical trial, the authentication system should be strengthened to remove the need for third parties, here trial stakeholders, and give participative control to the peer users. In the future, the complex data flow of a clinical trial could be tracked by using Blockchain, which core functionality, named Smart Contract, could help prevent clinical trial events not occurring in the correct chronological order, for example including patients before they consented or analysing case report form data before freezing the database. Globally, Blockchain could help with reliability, security, transparency and could be a consistent step toward reproducibility. PMID:29167732

  5. 40 CFR Appendix H to Part 75... - [Reserved

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 17 2013-07-01 2013-07-01 false [Reserved] H Appendix H to Part 75-Revised Traceability Protocol No. 1 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Appendix H to Part 75—Revised Traceability...

  6. EPA Traceability Protocol for Assay and Certification of Gaseous Calibration Standards

    EPA Science Inventory

    In 1997, the U.S. Environmental Protection Agency (EPA) in Research Triangle Park, North Carolina, revised its 1993 version of its traceability protocol for the assay and certification of compressed gas and permeation-device calibration standards. The protocol allows producers o...

  7. 40 CFR Appendix H to Part 75... - [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false [Reserved] H Appendix H to Part 75-Revised Traceability Protocol No. 1 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Appendix H to Part 75—Revised Traceability...

  8. Traceability System For Agricultural Productsbased on Rfid and Mobile Technology

    NASA Astrophysics Data System (ADS)

    Sugahara, Koji

    In agriculture, it is required to establish and integrate food traceability systems and risk management systems in order to improve food safety in the entire food chain. The integrated traceability system for agricultural products was developed, based on innovative technology of RFID and mobile computing. In order to identify individual products on the distribution process efficiently,small RFID tags with unique ID and handy RFID readers were applied. On the distribution process, the RFID tags are checked by using the readers, and transit records of the products are stored to the database via wireless LAN.Regarding agricultural production, the recent issues of pesticides misuse affect consumer confidence in food safety. The Navigation System for Appropriate Pesticide Use (Nouyaku-navi) was developed, which is available in the fields by Internet cell-phones. Based on it, agricultural risk management systems have been developed. These systems collaborate with traceability systems and they can be applied for process control and risk management in agriculture.

  9. Automatic summary generating technology of vegetable traceability for information sharing

    NASA Astrophysics Data System (ADS)

    Zhenxuan, Zhang; Minjing, Peng

    2017-06-01

    In order to solve problems of excessive data entries and consequent high costs for data collection in vegetable traceablility for farmers in traceability applications, the automatic summary generating technology of vegetable traceability for information sharing was proposed. The proposed technology is an effective way for farmers to share real-time vegetable planting information in social networking platforms to enhance their brands and obtain more customers. In this research, the influencing factors in the vegetable traceablility for customers were analyzed to establish the sub-indicators and target indicators and propose a computing model based on the collected parameter values of the planted vegetables and standard legal systems on food safety. The proposed standard parameter model involves five steps: accessing database, establishing target indicators, establishing sub-indicators, establishing standard reference model and computing scores of indicators. On the basis of establishing and optimizing the standards of food safety and traceability system, this proposed technology could be accepted by more and more farmers and customers.

  10. A false single nucleotide polymorphism generated by gene duplication compromises meat traceability.

    PubMed

    Sanz, Arianne; Ordovás, Laura; Zaragoza, Pilar; Sanz, Albina; de Blas, Ignacio; Rodellar, Clementina

    2012-07-01

    Controlling meat traceability using SNPs is an effective method of ensuring food safety. We have analyzed several SNPs to create a panel for bovine genetic identification and traceability studies. One of these was the transversion g.329C>T (Genbank accession no. AJ496781) on the cytochrome P450 17A1 gene, which has been included in previously published panels. Using minisequencing reactions, we have tested 701 samples belonging to eight Spanish cattle breeds. Surprisingly, an excess of heterozygotes was detected, implying an extreme departure from Hardy-Weinberg equilibrium (P<0.001). By alignment analysis and sequencing, we detected that the g.329C>T SNP is a false positive polymorphism, which allows us to explain the inflated heterozygotic value. We recommend that this ambiguous SNP, as well as other polymorphisms located in this region, should not be used in identification, traceability or disease association studies. Annotation of these false SNPs should improve association studies and avoid misinterpretations. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Maintaining Traceability in an Evolving Distributed Computing Environment

    NASA Astrophysics Data System (ADS)

    Collier, I.; Wartel, R.

    2015-12-01

    The management of risk is fundamental to the operation of any distributed computing infrastructure. Identifying the cause of incidents is essential to prevent them from re-occurring. In addition, it is a goal to contain the impact of an incident while keeping services operational. For response to incidents to be acceptable this needs to be commensurate with the scale of the problem. The minimum level of traceability for distributed computing infrastructure usage is to be able to identify the source of all actions (executables, file transfers, pilot jobs, portal jobs, etc.) and the individual who initiated them. In addition, sufficiently fine-grained controls, such as blocking the originating user and monitoring to detect abnormal behaviour, are necessary for keeping services operational. It is essential to be able to understand the cause and to fix any problems before re-enabling access for the user. The aim is to be able to answer the basic questions who, what, where, and when concerning any incident. This requires retaining all relevant information, including timestamps and the digital identity of the user, sufficient to identify, for each service instance, and for every security event including at least the following: connect, authenticate, authorize (including identity changes) and disconnect. In traditional grid infrastructures (WLCG, EGI, OSG etc.) best practices and procedures for gathering and maintaining the information required to maintain traceability are well established. In particular, sites collect and store information required to ensure traceability of events at their sites. With the increased use of virtualisation and private and public clouds for HEP workloads established procedures, which are unable to see 'inside' running virtual machines no longer capture all the information required. Maintaining traceability will at least involve a shift of responsibility from sites to Virtual Organisations (VOs) bringing with it new requirements for their logging infrastructures. VOs indeed need to fulfil a new operational role and become fully active participants in the incident response process. We present an analysis of the changing requirements to maintain traceability for virtualised and cloud based workflows with particular reference to the work of the WLCG Traceability Working Group.

  12. Experimental and Metrological Basis for SI-Traceable Infrared Radiance Measurements From Space

    NASA Astrophysics Data System (ADS)

    Gero, P. J.; Dykema, J. A.; Anderson, J. G.; Leroy, S. S.

    2007-12-01

    In order to establish a climate benchmark record and to be useful in interdecadal climate forecast testing, satellite measurements of high spectral resolution infrared radiance must have uncertainty estimates that can be proven beyond a doubt. An uncertainty in radiance of about 1 part in 1000 is required for climate applications. This can be accomplished by appealing to the best measurement practices of the metrology community. The International System of Units (SI) are linked to fundamental physical properties of matter, and can be realized anywhere in the world without bias. By doing so, one can make an accurate observation to within a specified uncertainty. Achieving SI-traceable radiance measurements from space is a novel requirement, and requires specialized sensor design and a disciplined experimental approach. Infrared remote sensing satellite instruments typically employ blackbody calibration targets, which are tied to the SI through Planck's law and the definition of the Kelvin. The blackbody temperature and emissivity, however, must be determined accurately on- orbit, in order for the blackbody emission scale to be SI-traceable. We outline a methodology of instrument design, pre-flight calibration and on-orbit diagnostics for realizing SI- traceable infrared radiance measurements. This instrument is intended as a component of the Climate Absolute Radiance and Refractivity Earth Observatory (CLARREO), a high priority recommendation of the National Research Council decadal survey. Calibration blackbodies for remote sensing differ from a perfect Planckian blackbody; thus the component uncertainties must be evaluated in order to confer traceability. We have performed traceability experiments in the laboratory to verify blackbody temperature, emissivity and the end-to-end radiance scale. We discuss the design of the Harvard standard blackbody and an intercomparison campaign that will be conducted with the GIFTS blackbody (University of Wisconsin, Madison) and radiometric calibration facilities at NIST. The GIFTS blackbody is a high-performance space-qualified design with a new generation of on-orbit thermometer calibration via miniaturized fixed point cells. NIST facilities allow the step-by-step measurement of blackbody surface properties, thermal properties, on-axis emissivity, and end-to-end radiometric performance. These activities will lay the experimental groundwork for achieving SI-traceable infrared radiance measurements on a satellite instrument.

  13. Final report on EURAMET.QM-S6/1195: Bilateral comparison of liquefied hydrocarbon mixtures in constant pressure (piston) cylinders

    NASA Astrophysics Data System (ADS)

    Brown, Andrew S.; Downey, Michael L.; Milton, Martin J. T.; van der Veen, Adriaan M. H.; Zalewska, Ewelina T.; Li, Jianrong

    2013-01-01

    Traceable liquid hydrocarbon mixtures are required in order to underpin measurements of the composition and other physical properties of LPG (liquefied petroleum gas) and LNG (liquefied natural gas), thus meeting the needs of an increasingly large European industrial market. The development of traceable liquid hydrocarbon standards by National Measurement Institutes (NMIs) was still at a relatively early stage at the time this comparison was proposed in 2011. NPL and VSL, who were the only NMIs active in this area, had developed methods for the preparation and analysis of such standards in constant pressure (piston) cylinders, but neither laboratory had Calibration and Measurement Capabilities (CMCs) for these mixtures. This report presents the results of EURAMET 1195, the first comparison of liquid hydrocarbon mixtures between NMIs, which assessed the preparation and analytical capabilities of NPL and VSL for these mixtures. The comparison operated between August 2011 and January 2012. Each laboratory prepared a liquid hydrocarbon standard with nominally the same composition and these standards were exchanged for analysis. The results of the comparison show a good agreement between the laboratories' results and the comparison reference values for the six components with amount fractions greater than 1.0 cmol/mol (propane, propene, iso-butene, n-butane, iso-butane and 1-butene). Measurement of the three components with lower amount fractions (1,3-butadiene, iso-pentane and n-pentane) proved more challenging. In all but one case, the differences from the comparison reference values for these three components were greater than the expanded measurement uncertainty. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by EURAMET, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. Traceability of Software Safety Requirements in Legacy Safety Critical Systems

    NASA Technical Reports Server (NTRS)

    Hill, Janice L.

    2007-01-01

    How can traceability of software safety requirements be created for legacy safety critical systems? Requirements in safety standards are imposed most times during contract negotiations. On the other hand, there are instances where safety standards are levied on legacy safety critical systems, some of which may be considered for reuse for new applications. Safety standards often specify that software development documentation include process-oriented and technical safety requirements, and also require that system and software safety analyses are performed supporting technical safety requirements implementation. So what can be done if the requisite documents for establishing and maintaining safety requirements traceability are not available?

  15. Standards fabrication to providing metrological traceability in micromass and nanoforce measurements results

    NASA Astrophysics Data System (ADS)

    Vargas Pereira, Thaiane; Beatrici, Anderson

    2018-03-01

    Some of the more sensitive weighing equipment available nowadays has its repeatability close to tenth of microgram. OIML characterize mass standards bigger them 1 mg, so in this range doesn’t exist direct traceability to the kg prototype. The ASTM has a characterization of mass standard 50, 100, 200 e 500 micrograms. This work have a purpose of providing traceability to mass measurement in microgram scale (nanonewton scale in force) with the confection and calibration of a standard weights collection. At this time were studied two materials, Tungsten and MetGlass2705M (MetGlass), and produced 12 mass standards.

  16. Capillary electrophoresis for the analysis of contaminants in emerging food safety issues and food traceability.

    PubMed

    Vallejo-Cordoba, Belinda; González-Córdova, Aarón F

    2010-07-01

    This review presents an overview of the applicability of CE in the analysis of chemical and biological contaminants involved in emerging food safety issues. Additionally, CE-based genetic analyzers' usefulness as a unique tool in food traceability verification systems was presented. First, analytical approaches for the determination of melamine and specific food allergens in different foods were discussed. Second, natural toxin analysis by CE was updated from the last review reported in 2008. Finally, the analysis of prion proteins associated with the "mad cow" crises and the application of CE-based genetic analyzers for meat traceability were summarized.

  17. High-resolution interferometic microscope for traceable dimensional nanometrology in Brazil

    NASA Astrophysics Data System (ADS)

    Malinovski, I.; França, R. S.; Lima, M. S.; Bessa, M. S.; Silva, C. R.; Couceiro, I. B.

    2016-07-01

    The double color interferometric microscope is developed for step height standards nanometrology traceable to meter definition via primary wavelength laser standards. The setup is based on two stabilized lasers to provide traceable measurements of highest possible resolution down to the physical limits of the optical instruments in sub-nanometer to micrometer range of the heights. The wavelength reference is He-Ne 633 nm stabilized laser, the secondary source is Blue-Green 488 nm grating laser diode. Accurate fringe portion is measured by modulated phase-shift technique combined with imaging interferometry and Fourier processing. Self calibrating methods are developed to correct systematic interferometric errors.

  18. Metrological traceability of holmium oxide solution

    NASA Astrophysics Data System (ADS)

    Gonçalves, D. E. F.; Gomes, J. F. S.; Alvarenga, A. P. D.; Borges, P. P.; Araujo, T. O.

    2018-03-01

    Holmium oxide solution was prepared as a candidate of certified reference material for spectrophotometer wavelength scale calibration. Here is presented the necessary steps for evaluation of the uncertainty and the establishment of metrological traceability for the production of this material. Preliminary results from the first produced batch are shown.

  19. Application of microsatellite markers as potential tools for traceability of Girgentana goat breed dairy products.

    PubMed

    Sardina, Maria Teresa; Tortorici, Lina; Mastrangelo, Salvatore; Di Gerlando, Rosalia; Tolone, Marco; Portolano, Baldassare

    2015-08-01

    In livestock, breed assignment may play a key role in the certification of products linked to specific breeds. Traceability of farm animals and authentication of their products can contribute to improve breed profitability and sustainability of animal productions with significant impact on the rural economy of particular geographic areas and on breed and biodiversity conservation. With the goal of developing a breed genetic traceability system for Girgentana dairy products, the aim of this study was to identify specific microsatellite markers able to discriminate among the most important Sicilian dairy goat breeds, in order to detect possible adulteration in Girgentana dairy products. A total of 20 microsatellite markers were analyzed on 338 individual samples from Girgentana, Maltese, and Derivata di Siria goat breeds. Specific microsatellite markers useful for traceability of dairy products were identified. Eight microsatellite markers showed alleles present at the same time in Maltese and Derivata di Siria and absent in Girgentana and, therefore, they were tested on DNA pools of the three breeds. Considering the electropherograms' results, only FCB20, SRCRSP5, and TGLA122 markers were tested on DNA samples extracted from cheeses of Girgentana goat breed. These three microsatellite markers could be applied in a breed genetic traceability system of Girgentana dairy products in order to detect adulteration due to Maltese and Derivata di Siria goat breeds. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. TWO NEW GAS STANDARDS PROGRAMS AT THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY

    EPA Science Inventory

    The EPA/NIST certified reference materials (CRM) program is being terminated and replaced with two new ones: the NIST Traceable Reference Materials (NTRM) and the Research Gas Mixture (RGM) programs. hese new programs are being implemented to provide NIST traceability to a wider ...

  1. Determination of NIST-Traceable Quantitative Weight Percentage Purity for G Agent Standards

    DTIC Science & Technology

    Nuclear magnetic resonance (NMR) with phosphorus -31 detection is described to determine the weight percent purity of feedstock samples of agents GA...and GD in a way that is National Institute of Standards and Technology (NIST)-traceable. A Precision and Accuracy test is described.

  2. 75 FR 37377 - Notice of Revision and Request for Extension of Approval of an Information Collection; Animal...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-29

    ... Traceability; Tribal Nations Using Systems for Location Identification AGENCY: Animal and Plant Health... using systems for location identification for the animal disease traceability framework and to request....aphis.usda.gov ). FOR FURTHER INFORMATION CONTACT: For information on Tribal Nations using location...

  3. Mercury Science Objectives and Traceability Within the BepiColombo Project: Optimising the Science Output of the Next Mission to Mercury

    NASA Astrophysics Data System (ADS)

    Besse, S.; Benkhoff, J.; Bentley, M.; Cornet, T.; Moissl, R.; Munoz, C.; Zender, J.

    2018-05-01

    The BepiColombo Science Ground Segment is developing, in collaboration with the instrument teams, targeted science traceability matrix of each instrument. They are defined in such a way that they can be tracked during the observation lifecycle.

  4. EPA Traceability Protocol for Assay and Certification of Gaseous Calibration Standards (EPA/600/R-12/531, May 2012)

    EPA Science Inventory

    In 1997, the U.S. Environmental Protection Agency (EPA) in Research Triangle Park, North Carolina, revised its 1993 version of its traceability protocol for the assay and certification of compressed gas and permeation-device calibration standards. The protocol allows producers of...

  5. Rapid immuno-analytical system physically integrated with lens-free CMOS image sensor for food-borne pathogens.

    PubMed

    Jeon, Jin-Woo; Kim, Jee-Hyun; Lee, Jong-Mook; Lee, Won-Ho; Lee, Do-Young; Paek, Se-Hwan

    2014-02-15

    To realize an inexpensive, pocket-sized immunosensor system, a rapid test devise based on cross-flow immuno-chromatography was physically combined with a lens-free CMOS image sensor (CIS), which was then applied to the detection of the food-borne pathogen, Salmonella typhimurium (S. typhimurium). Two CISs, each retaining 1.3 mega pixel array, were mounted on a printed circuit board to fabricate a disposable sensing module, being connectable with a signal detection system. For the bacterial analysis, a cellulose membrane-based immunosensing platform, ELISA-on-a-chip (EOC), was employed, being integrated with the CIS module, and the antigen-antibody reaction sites were aligned with the respective sensor. In such sensor construction, the chemiluminescent signals produced from the EOC are transferred directly into the sensors and are converted to electric signals on the detector. The EOC-CIS integrated sensor was capable of detecting a traceable amount of the bacterium (4.22 × 10(3)CFU/mL), nearly comparable to that adopting a sophisticated detector such as cooled-charge-coupled device, while having greatly reduced dimensions and cost. Upon coupling with immuno-magnetic separation, the sensor showed an additional 67-fold enhancement in the detection limit. Furthermore, a real sample test was carried out for fish muscles inoculated with a sample of 3.3CFU S. typhimurium per 10 g, which was able to be detected earlier than 6h after the onset of pre-enrichment by culture. © 2013 Elsevier B.V. All rights reserved.

  6. Development of an air flow calorimeter prototype for the measurement of thermal power released by large radioactive waste packages.

    PubMed

    Razouk, R; Beaumont, O; Failleau, G; Hay, B; Plumeri, S

    2018-03-01

    The estimation and control of the thermal power released by the radioactive waste packages are a key parameter in the management of radioactive waste geological repository sites. In the framework of the European project "Metrology for decommissioning nuclear facilities," the French National Agency of Radioactive Waste Management (ANDRA) collaborates with Laboratoire National de Métrologie et D'essais in order to measure the thermal power up to 500 W of typical real size radioactive waste packages (of at least 0.175 m 3 ) with an uncertainty better than 5% by using a measurement method traceable to the international system of units. One of the selected metrological approaches is based on the principles of air flow calorimetry. This paper describes in detail the development of the air flow calorimeter prototype as well as the design of a radioactive waste package simulator used for its calibration. Results obtained from the calibration of the calorimeter and from the determination of thermal powers are presented here with an investigation of the measurement uncertainties.

  7. Instantaneous Doppler Global Velocimetry Measurements of a Rotor Wake: Lessons Learned

    NASA Technical Reports Server (NTRS)

    Meyers, James; Fleming, Gary A.; Gorton, Susan Althoff; Berry, John D.

    1998-01-01

    A combined Doppler Global Velocimetry (DGV) and Projection Moir Interferometry (PMI) investigation of a helicopter rotor wake flow field and rotor blade deformation is presented. The three-component DGV system uses a single-frequency, frequency-doubled Nd:YAG laser to obtain instantaneous velocity measurements in the flow. The PMI system uses a pulsed laser-diode bar to obtain blade bending and twist measurements at the same instant that DGV measured the flow. The application of pulse lasers to DGV and PMI in large-scale wind tunnel applications represents a major step forward in the development of these technologies. As such, a great deal was learned about the difficulties of using these instruments to obtain instantaneous measurements in large facilities. Laser speckle and other image noise in the DGV data images were found to be traceable to the Nd:YAG laser. Although image processing techniques were used to virtually eliminate laser speckle noise, the source of low-frequency image noise is still under investigation. The PMI results agreed well with theoretical predictions of blade bending and twist.

  8. Development of an air flow calorimeter prototype for the measurement of thermal power released by large radioactive waste packages

    NASA Astrophysics Data System (ADS)

    Razouk, R.; Beaumont, O.; Failleau, G.; Hay, B.; Plumeri, S.

    2018-03-01

    The estimation and control of the thermal power released by the radioactive waste packages are a key parameter in the management of radioactive waste geological repository sites. In the framework of the European project "Metrology for decommissioning nuclear facilities," the French National Agency of Radioactive Waste Management (ANDRA) collaborates with Laboratoire National de Métrologie et D'essais in order to measure the thermal power up to 500 W of typical real size radioactive waste packages (of at least 0.175 m3) with an uncertainty better than 5% by using a measurement method traceable to the international system of units. One of the selected metrological approaches is based on the principles of air flow calorimetry. This paper describes in detail the development of the air flow calorimeter prototype as well as the design of a radioactive waste package simulator used for its calibration. Results obtained from the calibration of the calorimeter and from the determination of thermal powers are presented here with an investigation of the measurement uncertainties.

  9. Analyzing organic tea certification and traceability system within the Taiwanese tea industry.

    PubMed

    Wang, Mao-Chang; Yang, Chin-Ying

    2015-04-01

    We applied game theory to the organic tea certification process and traceability system used by the Taiwanese tea industry to elucidate the strategic choices made by tea farmers and organic tea certification agencies. Thus, this paper clarifies how relevant variables affect the organic certification process and traceability system used within the tea industry. The findings indicate that farmers who generate high revenues experience failures regarding tea deliveries, cash outflow, damage compensation, and quasi-rent. An additional problem included the high costs yielded when tea farmers colluded with or switched organic tea certification agencies. Furthermore, there could be decreasing levels of personal interest in planting non-organic tea and lowering the costs of planting organic tea and the managerial accounting costs of building comprehensive traceability systems; thus, the analysis yielded strong results and a superior equilibrium. This research is unprecedented, using an innovative model and providing a novel analysis structure for use in the tea industry. These results contribute to the field of literature and should serve as a valuable reference for members of the tea industry, government, and academia. © 2014 Society of Chemical Industry.

  10. [Study on brand traceability of vinegar based on near infrared spectroscopy technology].

    PubMed

    Guan, Xiao; Liu, Jing; Gu, Fang-Qing; Yang, Yong-Jian

    2014-09-01

    In the present paper, 152 vinegar samples with four different brands were chosen as research targets, and their near infrared spectra were collected by diffusion reflection mode and transmission mode, respectively. Furthermore, the brand traceability models for edible vinegar were constructed. The effects of the collection mode and pretreatment methods of spectrum on the precision of traceability models were investigated intensively. The models constructed by PLS1-DA modeling method using spectrum data of 114 training samples were applied to predict 38 test samples, and R2, RMSEC and RMSEP of the model based on transmission mode data were 0.92, 0.113 and 0.127, respectively, with recognition rate of 76.32%, and those based on diffusion reflection mode data were 0.97, 0.102 and 0.119, with recognition rate of 86.84%. The results demonstrated that the near infrared spectrum combined with PLS1-DA can be used to establish the brand traceability models for edible vinegar, and diffuse reflection mode is more beneficial for predictive ability of the model.

  11. Geographical traceability of virgin olive oils from south-western Spain by their multi-elemental composition.

    PubMed

    Beltrán, María; Sánchez-Astudillo, María; Aparicio, Ramón; García-González, Diego L

    2015-02-15

    The geographical traceability of virgin olive oil can be controlled by chemical species that are linked to the production area. Trace elements are among these species. The hypothesis is that the transfer of elements from the soil to the oil is subjected to minor variations and therefore this chemical information can be used for geographical traceability. In order to confirm this hypothesis, the trace elements of virgin olive oils from south-western Spain were analysed, and the same elements were determined in the corresponding olive-pomaces and soils. The differences in the concentration were studied according to cultivars and locations. Results show some coincidences in the selection of elements in soils (W, Fe, Na), olive-pomace (W, Fe, Na, Mg, Mn, Ca, Ba, Li) and olive oils (W, Fe, Mg, Mn, Ca, Ba, Li, Bi), which supports their utility in traceability. In the case of olive oils, 93% of the samples were correctly classified in their geographical origins (96% for Beas, 77% for Gibraleón, 91% for Niebla, and 100% for Sanlúcar de Guadiana). Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. New NIST Photomask Linewidth Standard

    NASA Astrophysics Data System (ADS)

    Potzick, James E.; Pedulla, J. Marc; Stocker, Michael T.

    2002-12-01

    NIST is preparing to issue the next generation in its line of binary photomask linewidth standards. Called SRM 2059, it was developed for calibrating microscopes used to measure linewidths on photomasks, and consists of antireflecting chrome line and space patterns on a 6 inch quartz substrate ( 6 × 6 × 0.25 inches, or 15.2 × 15.2 × 0.635 cm). Certified line- and space-widths range from nominal 0.250 μm to 32 μm, and pitches from 0.5 μm to 250 μm, and are traceable to the definition of the meter. NIST's reference value, the definition of the meter, is well defined and unconditionally stable. Any replacement or duplicate NIST linewidth standard will be traceable to this same reference, and thus traceable to any other NIST length standard. Such measurement traceability can be achieved only by evaluating the measurement uncertainty (not just the repeatability) of each length comparison in the metrology chain between the definition of the meter and the NIST linewidth standard. This process results in a confidence interval about the calibration result that has a 95% probability of containing the true value. While the meter (and the μm) are well-defined, the geometrical width of a chrome line with nonrectangular cross section is not, and so the "true value" linewidth must be carefully defined to best meet users' needs. The paper and presentation will describe how these mask features are measured at NIST and how their measurement traceability is accomplished.

  13. Detection and traceability of genetically modified organisms in the food production chain.

    PubMed

    Miraglia, M; Berdal, K G; Brera, C; Corbisier, P; Holst-Jensen, A; Kok, E J; Marvin, H J P; Schimmel, H; Rentsch, J; van Rie, J P P F; Zagon, J

    2004-07-01

    Both labelling and traceability of genetically modified organisms are current issues that are considered in trade and regulation. Currently, labelling of genetically modified foods containing detectable transgenic material is required by EU legislation. A proposed package of legislation would extend this labelling to foods without any traces of transgenics. These new legislations would also impose labelling and a traceability system based on documentation throughout the food and feed manufacture system. The regulatory issues of risk analysis and labelling are currently harmonised by Codex Alimentarius. The implementation and maintenance of the regulations necessitates sampling protocols and analytical methodologies that allow for accurate determination of the content of genetically modified organisms within a food and feed sample. Current methodologies for the analysis of genetically modified organisms are focused on either one of two targets, the transgenic DNA inserted- or the novel protein(s) expressed- in a genetically modified product. For most DNA-based detection methods, the polymerase chain reaction is employed. Items that need consideration in the use of DNA-based detection methods include the specificity, sensitivity, matrix effects, internal reference DNA, availability of external reference materials, hemizygosity versus homozygosity, extrachromosomal DNA, and international harmonisation. For most protein-based methods, enzyme-linked immunosorbent assays with antibodies binding the novel protein are employed. Consideration should be given to the selection of the antigen bound by the antibody, accuracy, validation, and matrix effects. Currently, validation of detection methods for analysis of genetically modified organisms is taking place. In addition, new methodologies are developed, including the use of microarrays, mass spectrometry, and surface plasmon resonance. Challenges for GMO detection include the detection of transgenic material in materials with varying chromosome numbers. The existing and proposed regulatory EU requirements for traceability of genetically modified products fit within a broader tendency towards traceability of foods in general and, commercially, towards products that can be distinguished from each other. Traceability systems document the history of a product and may serve the purpose of both marketing and health protection. In this framework, segregation and identity preservation systems allow for the separation of genetically modified and non-modified products from "farm to fork". Implementation of these systems comes with specific technical requirements for each particular step of the food processing chain. In addition, the feasibility of traceability systems depends on a number of factors, including unique identifiers for each genetically modified product, detection methods, permissible levels of contamination, and financial costs. In conclusion, progress has been achieved in the field of sampling, detection, and traceability of genetically modified products, while some issues remain to be solved. For success, much will depend on the threshold level for adventitious contamination set by legislation. Copryright 2004 Elsevier Ltd.

  14. Traceability of different apple varieties by multivariate analysis of isotope ratio mass spectrometry data.

    PubMed

    Mimmo, Tanja; Camin, Federica; Bontempo, Luana; Capici, Calogero; Tagliavini, Massimo; Cesco, Stefano; Scampicchio, Matteo

    2015-11-15

    The awareness of customers of the origin of foods has become an important issue. The growing demand for foods that are healthy, safe and of high quality has increased the need for traceability and clear labelling. Thus, this study investigates the capability of C and N stable isotope ratios to determine the geographical origin of several apple varieties grown in northern Italy. Four apple varieties (Cripps Pink, Gala, Golden Delicious, Granny Smith) have been sampled in orchards located in the Districts of Bolzano, Ferrara, Verona and Udine (northern Italy). Carbon (δ(13) C) and nitrogen (δ(15) N) isotope values of the whole apple fruits and three sub-fractions (peel, pulp and seed) have been determined simultaneously by isotope ratio mass spectrometry. The δ(13) C and δ(15) N values of apples and apple sub-fractions, such as peel, seed and pulp, were significantly affected by the geographical origin and the fruit variety. The four varieties could be distinguished to a certain extent only within each district. A 99% correct identification of the samples according to their origin was, however, achieved by cross validation with the 'leave-one-out' method. This study proves the potential of stable isotopes to discriminate the geographical origin of apples grown in orchards located only a few hundreds of kilometres apart. Stable isotopes were also able to discriminate different apple varieties, although only within small geographical areas. Copyright © 2015 John Wiley & Sons, Ltd.

  15. Force Measurement Services at Kebs: AN Overview of Equipment, Procedures and Uncertainty

    NASA Astrophysics Data System (ADS)

    Bangi, J. O.; Maranga, S. M.; Nganga, S. P.; Mutuli, S. M.

    This paper describes the facilities, instrumentation and procedures currently used in the force laboratory at the Kenya Bureau of Standards (KEBS) for force measurement services. The laboratory uses the Force Calibration Machine (FCM) to calibrate force-measuring instruments. The FCM derives its traceability via comparisons using reference transfer force transducers calibrated by the Force Standard Machines (FSM) of a National Metrology Institute (NMI). The force laboratory is accredited to ISO/IEC 17025 by the Germany Accreditation Body (DAkkS). The accredited measurement scope of the laboratory is 1 MN to calibrate force transducers in both compression and tension modes. ISO 376 procedures are used while calibrating force transducers. The KEBS reference transfer standards have capacities of 10, 50, 300 and 1000 kN to cover the full range of the FCM. The uncertainty in the forces measured by the FCM were reviewed and determined in accordance to the new EURAMET calibration guide. The relative expanded uncertainty of force W realized by FCM was evaluated in a range from 10 kN-1 MN, and was found to be 5.0 × 10-4 with the coverage factor k being equal to 2. The overall normalized error (En) of the comparison results was also found to be less than 1. The accredited Calibration and Measurement Capability (CMC) of the KEBS force laboratory was based on the results of those intercomparisons. The FCM enables KEBS to provide traceability for the calibration of class ‘1’ force instruments as per the ISO 376.

  16. Advanced engineering environment pilot project.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schwegel, Jill; Pomplun, Alan R.; Abernathy, Rusty

    2006-10-01

    The Advanced Engineering Environment (AEE) is a concurrent engineering concept that enables real-time process tooling design and analysis, collaborative process flow development, automated document creation, and full process traceability throughout a product's life cycle. The AEE will enable NNSA's Design and Production Agencies to collaborate through a singular integrated process. Sandia National Laboratories and Parametric Technology Corporation (PTC) are working together on a prototype AEE pilot project to evaluate PTC's product collaboration tools relative to the needs of the NWC. The primary deliverable for the project is a set of validated criteria for defining a complete commercial off-the-shelf (COTS) solutionmore » to deploy the AEE across the NWC.« less

  17. RELAP-7 Software Verification and Validation Plan: Requirements Traceability Matrix (RTM) Part 1 – Physics and numerical methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Choi, Yong Joon; Yoo, Jun Soo; Smith, Curtis Lee

    2015-09-01

    This INL plan comprehensively describes the Requirements Traceability Matrix (RTM) on main physics and numerical method of the RELAP-7. The plan also describes the testing-based software verification and validation (SV&V) process—a set of specially designed software models used to test RELAP-7.

  18. Hg0 and HgCl2 Reference Gas Standards: NIST Traceability and Comparability (And EPA ALT Methods for Hg and HCl )

    EPA Science Inventory

    EPA and NIST have collaborated to establish the necessary procedures for establishing the required NIST traceability of commercially-provided Hg0 and HgCl2 reference generators. This presentation will discuss the approach of a joint EPA/NIST study to accurately quantify the tru...

  19. Application of binomial and multinomial probability statistics to the sampling design process of a global grain tracing and recall system

    USDA-ARS?s Scientific Manuscript database

    Small, coded, pill-sized tracers embedded in grain are proposed as a method for grain traceability. A sampling process for a grain traceability system was designed and investigated by applying probability statistics using a science-based sampling approach to collect an adequate number of tracers fo...

  20. Research and Construction of DC Energy Measurement Traceability Technology

    NASA Astrophysics Data System (ADS)

    Zhi, Wang; Maotao, Yang; Jing, Yang

    2018-02-01

    With the implementation of energy saving and emission reduction policies, DC energy metering has been widely used in many fields. In view of the lack of a DC energy measurementtraceability system, in combination with the process of downward measurement transfer in relation to the DC charger-based field calibration technology and DC energy meter and shunt calibration technologies, the paper proposed DC fast charging, high DC, small DC voltage output and measuring technologies, and built a time-based plan by converting high DC voltage into low voltage and high current into low current and then into low voltage, leaving DC energy traceable to national standards in terms of voltage, current and time and thus filling in the gap in DC energy measurement traceability.

  1. Transgene traceability in transgenic mice: a bioanalytical approach for potential gene-doping analysis.

    PubMed

    Bogani, Patrizia; Spiriti, Maria Michela; Lazzarano, Stefano; Arcangeli, Annarosa; Buiatti, Marcello; Minunni, Maria

    2011-11-01

    The World Anti-Doping Agency fears the use of gene doping to enhance athletic performances. Thus, a bioanalytical approach based on end point PCR for detecting markers' of transgenesis traceability was developed. A few sequences from two different vectors using an animal model were selected and traced in different tissues and at different times. In particular, enhanced green fluorescent protein gene and a construct-specific new marker were targeted in the analysis. To make the developed detection approach open to future routine doping analysis, matrices such as urine and tears as well blood were also tested. This study will have impact in evaluating the vector transgenes traceability for the detection of a gene doping event by non-invasive sampling.

  2. State of the art stationary and mobile infrastructure for the dynamic generation and dilution of traceable reference gas mixtures of Ammonia at ambient air amount fractions

    NASA Astrophysics Data System (ADS)

    Leuenberger, Daiana; Pascale, Céline; Guillevic, Myriam; Ackermann, Andreas; Niederhauser, Bernhard

    2017-04-01

    Ammonia (NH3) in the atmosphere is the major precursor for neutralising atmospheric acids and is thus affecting not only the long-range transport of sulphur dioxide and nitrogen oxides but also stabilises secondary particulate matter. These aerosols have negative impacts on air quality and human health. Moreover, they negatively affect terrestrial ecosystems after deposition. NH3 has been included in the air quality monitoring networks and emission reduction directives of European nations. Atmospheric concentrations are in the order of 0.5-500 nmol/mol. However, the lowest substance amount fraction of available certified reference material (CRM) is 10 μmol/mol. This due to the fact that adsorption on the walls of aluminium cylinders and desorption as pressure in the cylinder decreases cause substantial instabilities in the amount fractions of the gas mixtures. Moreover, analytical techniques to be calibrated are very diverse and cause challenges for the production and application of CRM. The Federal Institute of Metrology METAS has developed, partially in the framework of EMRP JRP ENV55 MetNH3, an infrastructure to meet with the different requirements in order to generate SI-traceable NH3 reference gas mixtures dynamically in the amount fraction range 0.5-500 nmol/mol and with uncertainties UNH3 <3%. The infrastructure consists of a stationary as well as a mobile device for full flexibility in the application: In the stationary system, a magnetic suspension balance monitors the specific temperature and pressure dependent mass loss over time of the pure substance in a permeation tube (here NH3) by permeation through a membrane into a constant flow of carrier gas. Subsequently, this mixture is diluted with a system of thermal mass flow controllers in one or two consecutive steps to desired amount fractions. The permeation tube with calibrated permeation rate (mass loss over time previously determined in the magnetic suspension balance) can be transferred into the temperature-regulated permeation chamber of a newly developed mobile reference gas generator (ReGaS1). In addition to the permeation chamber it consists of the same dilution system as afore mentioned, stationary system. All components are fully traceable to SI standards. Considerable effort has been made to minimise adsorption on the gas-wetted stainless steel surfaces and thus to reduce stabilisation times by applying the SilcoNert2000® coating substance. Analysers can be connected directly to both, stationary and mobile systems for calibration. Moreover, the resulting gas mixture can also be pressurised into coated cylinders by cryo-filling. The mobile system as well as these cylinders can be applied for calibrations in other laboratories and in the field. In addition, an SI traceable system based on a cascade of critical orifices has been established to dilute NH3 mixtures in the order of μmol/mol stored in cylinders for the participation in the international key-comparison CCQM K117. It is planned to establish this system to calibrate and re-sample gas cylinders due to its very economical gas use. Here we present insights into the development of said infrastructure and results of the first performance tests. Moreover, we include results of the study on adsorption/desorption effects in dry as well as humidified matrix gas into the discussion on the generation of reference gas mixtures. Acknowledgement: This work was supported by the European Metrology Research Programme (EMRP). The EMRP is jointly funded by the EMRP participating countries within EURAMET and the European Union.

  3. Traceability Assessment and Performance Evaluation of Results for Measurement of Abbott Clinical Chemistry Assays on 4 Chemistry Analyzers.

    PubMed

    Lim, Jinsook; Song, Kyung Eun; Song, Sang Hoon; Choi, Hyun-Jung; Koo, Sun Hoe; Kwon, Gye Choel

    2016-05-01

    -The traceability of clinical results to internationally recognized and accepted reference materials and reference measurement procedures has become increasingly important. Therefore, the establishment of traceability has become a mandatory requirement for all in vitro diagnostics devices. -To evaluate the traceability of the Abbott Architect c8000 system (Abbott Laboratories, Abbott Park, Illinois), consisting of calibrators and reagents, across 4 different chemistry analyzers, and to evaluate its general performance on the Toshiba 2000FR NEO (Toshiba Medical Systems Corporation, Otawara-shi, Tochigi-ken, Japan). -For assessment of traceability, secondary reference materials were evaluated 5 times, and then bias was calculated. Precision, linearity, and carryover were determined according to the guidelines of the Clinical and Laboratory Standards Institute (Wayne, Pennsylvania). -The biases from 4 different analyzers ranged from -2.33% to 2.70% on the Toshiba 2000FR NEO, -2.33% to 5.12% on the Roche Hitachi 7600 (Roche Diagnostics International, Basel, Switzerland), -0.93% to 2.87% on the Roche Modular, and -2.16% to 2.86% on the Abbott Architect c16000. The total coefficients of variance of all analytes were less than 5%. The coefficients of determination (R(2)) were more than 0.9900. The carryover rate ranged from -0.54% to 0.17%. -Abbott clinical chemistry assays met the performance criteria based on desirable biological variation for precision, bias, and total error. They also showed excellent linearity and carryover. Therefore, these clinical chemistry assays were found to be accurate and reliable and are readily applicable on the various platforms used in this study.

  4. Stennis Space Center Verification & Validation Capabilities

    NASA Technical Reports Server (NTRS)

    Pagnutti, Mary; Ryan, Robert E.; Holekamp, Kara; O'Neal, Duane; Knowlton, Kelly; Ross, Kenton; Blonski, Slawomir

    2007-01-01

    Scientists within NASA#s Applied Research & Technology Project Office (formerly the Applied Sciences Directorate) have developed a well-characterized remote sensing Verification & Validation (V&V) site at the John C. Stennis Space Center (SSC). This site enables the in-flight characterization of satellite and airborne high spatial resolution remote sensing systems and their products. The smaller scale of the newer high resolution remote sensing systems allows scientists to characterize geometric, spatial, and radiometric data properties using a single V&V site. The targets and techniques used to characterize data from these newer systems can differ significantly from the techniques used to characterize data from the earlier, coarser spatial resolution systems. Scientists have used the SSC V&V site to characterize thermal infrared systems. Enhancements are being considered to characterize active lidar systems. SSC employs geodetic targets, edge targets, radiometric tarps, atmospheric monitoring equipment, and thermal calibration ponds to characterize remote sensing data products. Similar techniques are used to characterize moderate spatial resolution sensing systems at selected nearby locations. The SSC Instrument Validation Lab is a key component of the V&V capability and is used to calibrate field instrumentation and to provide National Institute of Standards and Technology traceability. This poster presents a description of the SSC characterization capabilities and examples of calibration data.

  5. Systems Engineering for Space Exploration Medical Capabilities

    NASA Technical Reports Server (NTRS)

    Mindock, Jennifer; Reilly, Jeffrey; Rubin, David; Urbina, Michelle; Hailey, Melinda; Hanson, Andrea; Burba, Tyler; McGuire, Kerry; Cerro, Jeffrey; Middour, Chris; hide

    2017-01-01

    Human exploration missions that reach destinations beyond low Earth orbit, such as Mars, will present significant new challenges to crew health management. For the medical system, lack of consumable resupply, evacuation opportunities, and real-time ground support are key drivers toward greater autonomy. Recognition of the limited mission and vehicle resources available to carry out exploration missions motivates the Exploration Medical Capability (ExMC) Element's approach to enabling the necessary autonomy. The Element's work must integrate with the overall exploration mission and vehicle design efforts to successfully provide exploration medical capabilities. ExMC is applying systems engineering principles and practices to accomplish its goals. This paper discusses the structured and integrative approach that is guiding the medical system technical development. Assumptions for the required levels of care on exploration missions, medical system goals, and a Concept of Operations are early products that capture and clarify stakeholder expectations. Model-Based Systems Engineering techniques are then applied to define medical system behavior and architecture. Interfaces to other flight and ground systems, and within the medical system are identified and defined. Initial requirements and traceability are established, which sets the stage for identification of future technology development needs. An early approach for verification and validation, taking advantage of terrestrial and near-Earth exploration system analogs, is also defined to further guide system planning and development.

  6. A Calibration Facility for Dew Point in Air up to 1 MPa

    NASA Astrophysics Data System (ADS)

    Carroll, P. A.; Bell, S. A.; Stevens, M.

    2015-12-01

    The provision of primary dew-point standards for humidified air and nitrogen at atmospheric pressure is well established, and measurement traceability to these standards provides confidence in a vast number of air humidity measurements. However, hygrometers are used industrially at a wide range of pressures. Both the performance of hygrometers and the properties of humid gases are known to vary with gas pressure. The pressure-dependence of gas non-ideality for air-water mixtures (water-vapor enhancement factor) is well enough known at moderate pressures, but there remains a need to characterize hygrometers at the pressure of use. To address this, a humidity calibration capability of wider scope is under development at the UK National Physical Laboratory (NPL). As an initial stage in the development of this capability, a humidity standard generating air or nitrogen in the dew-point range from -60° C to +10° C, at pressures up to 1 MPa (10 bar) has been validated for the calibration of hygrometers. The expanded uncertainty of the dew-point generator in this range with a coverage factor k= 2 is ± 0.07° C.

  7. Ruggedness of 2D code printed on grain tracers for implementing a prospective grain traceability system to the bulk grain delivery system

    USDA-ARS?s Scientific Manuscript database

    Food-grade tracers were printed with two-dimensional Data Matrix (DM) barcode so that they could carry simulated identifying information about grain as part of a prospective traceability system. The key factor in evaluating the tracers was their ability to be read with a code scanner after being rem...

  8. Theater Blood Application Was Not Effectively Developed and Implemented

    DTIC Science & Technology

    2015-07-17

    blood product by unit; and • monitor non- Food and Drug Administration Blood Product Testing. The CONOPS document also identified over 400 specific...time of a transfusion. However, this requirement was not identified in the CONOPS document. Further, PEO DHCS officials provided a traceability ...the CONOPS document, requirements management database, and the traceability matrix increased the risk that the Theater Blood Application

  9. Food quality and safety: traceability and labeling.

    PubMed

    Lupien, John R

    2005-01-01

    This article discusses food systems in general, their development over the past 120 years, and realities and problems faced by a world population of over 6 billion people. Various food and feed problems are mentioned, and the concept of "traceability" is discussed in the context of the broader and more useful approach of using "good practices" at all levels of the food chain.

  10. Metrological Traceability in the Social Sciences: A Model from Reading Measurement

    NASA Astrophysics Data System (ADS)

    Stenner, A. Jackson; Fisher, William P., Jr.

    2013-09-01

    The central importance of reading ability in learning makes it the natural place to start in formative and summative assessments in education. The Lexile Framework for Reading constitutes a commercial metrological traceability network linking books, test results, instructional materials, and students in elementary and secondary English and Spanish language reading education in the U.S., Canada, Mexico, and Australia.

  11. Measurement uncertainty: Friend or foe?

    PubMed

    Infusino, Ilenia; Panteghini, Mauro

    2018-02-02

    The definition and enforcement of a reference measurement system, based on the implementation of metrological traceability of patients' results to higher order reference methods and materials, together with a clinically acceptable level of measurement uncertainty, are fundamental requirements to produce accurate and equivalent laboratory results. The uncertainty associated with each step of the traceability chain should be governed to obtain a final combined uncertainty on clinical samples fulfilling the requested performance specifications. It is important that end-users (i.e., clinical laboratory) may know and verify how in vitro diagnostics (IVD) manufacturers have implemented the traceability of their calibrators and estimated the corresponding uncertainty. However, full information about traceability and combined uncertainty of calibrators is currently very difficult to obtain. Laboratory professionals should investigate the need to reduce the uncertainty of the higher order metrological references and/or to increase the precision of commercial measuring systems. Accordingly, the measurement uncertainty should not be considered a parameter to be calculated by clinical laboratories just to fulfil the accreditation standards, but it must become a key quality indicator to describe both the performance of an IVD measuring system and the laboratory itself. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  12. Traceability information carriers. The technology backgrounds and consumers' perceptions of the technological solutions.

    PubMed

    Chrysochou, Polymeros; Chryssochoidis, George; Kehagia, Olga

    2009-12-01

    The implementation of traceability in the food supply chain has reinforced adoption of technologies with the ability to track forward and trace back product-related information. Based on the premise that these technologies can be used as a means to provide product-related information to consumers, this paper explores the perceived benefits and drawbacks of such technologies. The aim is to identify factors that influence consumers' perceptions of such technologies, and furthermore to advise the agri-food business on issues that they should consider prior to the implementation of such technologies in their production lines. For the purposes of the study, a focus group study was conducted across 12 European countries, while a set of four different technologies used as a means to provide traceability information to consumers was the focal point of the discussions in each focus group. Results show that the amount of and confidence in the information provided, perceived levels of convenience, impact on product quality and safety, impact on consumers' health and the environment, and potential consequences on ethical and privacy liberties constitute important factors influencing consumers' perceptions of technologies that provide traceability.

  13. Non-destructive geographical traceability of sea cucumber (Apostichopus japonicus) using near infrared spectroscopy combined with chemometric methods

    PubMed Central

    Cai, Rui; Wang, Shisheng; Tang, Bo; Li, Yueqing; Zhao, Weijie

    2018-01-01

    Sea cucumber is the major tonic seafood worldwide, and geographical origin traceability is an important part of its quality and safety control. In this work, a non-destructive method for origin traceability of sea cucumber (Apostichopus japonicus) from northern China Sea and East China Sea using near infrared spectroscopy (NIRS) and multivariate analysis methods was proposed. Total fat contents of 189 fresh sea cucumber samples were determined and partial least-squares (PLS) regression was used to establish the quantitative NIRS model. The ordered predictor selection algorithm was performed to select feasible wavelength regions for the construction of PLS and identification models. The identification model was developed by principal component analysis combined with Mahalanobis distance and scaling to the first range algorithms. In the test set of the optimum PLS models, the root mean square error of prediction was 0.45, and correlation coefficient was 0.90. The correct classification rates of 100% were obtained in both identification calibration model and test model. The overall results indicated that NIRS method combined with chemometric analysis was a suitable tool for origin traceability and identification of fresh sea cucumber samples from nine origins in China. PMID:29410795

  14. Non-destructive geographical traceability of sea cucumber (Apostichopus japonicus) using near infrared spectroscopy combined with chemometric methods.

    PubMed

    Guo, Xiuhan; Cai, Rui; Wang, Shisheng; Tang, Bo; Li, Yueqing; Zhao, Weijie

    2018-01-01

    Sea cucumber is the major tonic seafood worldwide, and geographical origin traceability is an important part of its quality and safety control. In this work, a non-destructive method for origin traceability of sea cucumber ( Apostichopus japonicus ) from northern China Sea and East China Sea using near infrared spectroscopy (NIRS) and multivariate analysis methods was proposed. Total fat contents of 189 fresh sea cucumber samples were determined and partial least-squares (PLS) regression was used to establish the quantitative NIRS model. The ordered predictor selection algorithm was performed to select feasible wavelength regions for the construction of PLS and identification models. The identification model was developed by principal component analysis combined with Mahalanobis distance and scaling to the first range algorithms. In the test set of the optimum PLS models, the root mean square error of prediction was 0.45, and correlation coefficient was 0.90. The correct classification rates of 100% were obtained in both identification calibration model and test model. The overall results indicated that NIRS method combined with chemometric analysis was a suitable tool for origin traceability and identification of fresh sea cucumber samples from nine origins in China.

  15. Importance of Calibration/Validation Traceability for Multi-Sensor Imaging Spectrometry Applications

    NASA Technical Reports Server (NTRS)

    Thome, K.

    2017-01-01

    Knowledge of calibration traceability is essential for ensuring the quality of data products relying on multiple sensors and especially true for imaging spectrometers. The current work discusses the expected impact that imaging spectrometers have in ensuring radiometric traceability for both multispectral and hyperspectral products. The Climate Absolute Radiance and Refractivity Observatory Pathfinder mission is used to show the role that high-accuracy imaging spectrometers can play in understanding test sites used for vicarious calibration of sensors. The associated Solar, Lunar for Absolute Reflectance Imaging Spectroradiometer calibration demonstration system is used to illustrate recent advances in laboratory radiometric calibration approaches that will allow both the use of imaging spectrometers as calibration standards as well as to ensure the consistency of the multiple imaging spectrometers expected to be on orbit in the next decade.

  16. Decision Model for Planning and Scheduling of Seafood Product Considering Traceability

    NASA Astrophysics Data System (ADS)

    Agustin; Mawengkang, Herman; Mathelinea, Devy

    2018-01-01

    Due to the global challenges, it is necessary for an industrial company to integrate production scheduling and distribution planning, in order to be more efficient and to get more economics advantages. This paper presents seafood production planning and scheduling of a seafood manufacture company which produces simultaneously multi kind of seafood products, located at Aceh Province, Indonesia. The perishability nature of fish highly restricts its storage duration and delivery conditions. Traceability is a tracking requirement to check whether the quality of the product is satisfied. The production and distribution planning problem aims to meet customer demand subject to traceability of the seafood product and other restrictions. The problem is modeled as a mixed integer linear program, and then it is solved using neighborhood search approach.

  17. An intelligent traceability system: Efficient tool for a supply chain sustainability

    NASA Astrophysics Data System (ADS)

    Bougdira, Abdesselam; Ahaitouf, Abdelaziz; Akharraz, Ismail

    2016-07-01

    The supply chain sustainability becomes a necessity for a smooth, a rapid and a fluid economic transaction. To reach a sustainable supply chain, we propose to focus attention on products and their lifecycle. So, we consider the traceability as a major success key to ensure the supply chain sustainability. For that, we consider a supply chain design that use an intelligent products traced by an intelligent traceability system. This system identifies, restores history and properties of a product, besides it tracks, in real-time a product. This solution can, also, bring, in the product environment, appropriate adjustments to prevent any risk of threatening qualities for the product. So, it helps supply chain contributors making the sustainable adjustments and the instant benchmark of the supply chain sustainability.

  18. Comparison of clast and matrix dispersal in till: Charlo-Atholville area, north-central New Brunswick

    USGS Publications Warehouse

    Dickson, M.L.; Broster, B.E.; Parkhill, M.A.

    2004-01-01

    Striations and dispersal patterns for till clasts and matrix geochemistry are used to define flow directions of glacial transport across an area of about 800km2 in the Charlo-Atholville area of north-central New Brunswick. A total of 170 clast samples and 328 till matrix samples collected for geochemical analysis across the region, were analyzed for a total of 39 elements. Major lithologic contacts used here to delineate till clast provenance were based on recent bedrock mapping. Eleven known mineral occurrences and a gossan are used to define point source targets for matrix geochemical dispersal trains and to estimate probable distance and direction of transport from unknown sources. Clast trains are traceable for distances of approximately 10 km, whereas till geochemical dispersal patterns are commonly lost within 5 km of transport. Most dispersal patterns reflect more than a single direction of glacial transport. These data indicate that a single till sheet, 1-4 m thick, was deposited as the dominant ice-flow direction fluctuated between southeastward, eastward, and northward over the study area. Directions of early flow represent changes in ice sheet dominance, first from the northwest and then from the west. Locally, eastward and northward flow represent the maximum erosive phases. The last directions of flow are likely due to late glacial ice sheet drawdown towards the valley outlet at Baie des Chaleurs.

  19. NIST-Traceable NMR Method to Determine Quantitative Weight Percentage Purity of Mustard (HD) Feedstock Samples

    DTIC Science & Technology

    2018-01-01

    ECBC-TR-1506 NIST-TRACEABLE NMR METHOD TO DETERMINE QUANTITATIVE WEIGHT PERCENTAGE PURITY OF MUSTARD (HD) FEEDSTOCK SAMPLES David J...McGarvey RESEARCH AND TECHNOLOGY DIRECTORATE William R. Creasy LEIDOS, INC. Abingdon, MD 21009-1261 Theresa R. Connell EXCET, INC...be construed as an official Department of the Army position unless so designated by other authorizing documents. REPORT DOCUMENTATION PAGE

  20. The application of compound-specific isotope analysis of fatty acids for traceability of sea cucumber (Apostichopus japonicus) in the coastal areas of China.

    PubMed

    Liu, Yu; Zhang, Xufeng; Li, Ying; Wang, Haixia

    2017-11-01

    Geographical origin traceability is an important issue for controlling the quality of seafood and safeguarding the interest of consumers. In the present study, a new method of compound-specific isotope analysis (CSIA) of fatty acids was established to evaluate its applicability in establishing the origin traceability of Apostichopus japonicus in the coastal areas of China. Moreover, principal component analysis (PCA) and discriminant analysis (DA) were applied to distinguish between the origins of A. japonicus. The results show that the stable carbon isotope compositions of fatty acids of A. japonicus significantly differ in terms of both season and origin. They also indicate that the stable carbon isotope composition of fatty acids could effectively discriminate between the origins of A. japonicus, except for between Changhai Island and Zhangzi Island in the spring of 2016 because of geographical proximity or the similarity of food sources. The fatty acids that have the highest contribution to identifying the geographical origins of A. japonicus are C22:6n-3, C16:1n-7, C20:5n-3, C18:0 and C23:1n-9, when considering the fatty acid contents, the stable carbon isotope composition of fatty acids and the results of the PCA and DA. We conclude that CSIA of fatty acids, combined with multivariate statistical analysis such as PCA and DA, may be an effective tool for establishing the traceability of A. japonicus in the coastal areas of China. The relevant conclusions of the present study provide a new method for determining the traceability of seafood or other food products. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  1. Evaluating droplet digital PCR for the quantification of human genomic DNA: converting copies per nanoliter to nanograms nuclear DNA per microliter.

    PubMed

    Duewer, David L; Kline, Margaret C; Romsos, Erica L; Toman, Blaza

    2018-05-01

    The highly multiplexed polymerase chain reaction (PCR) assays used for forensic human identification perform best when used with an accurately determined quantity of input DNA. To help ensure the reliable performance of these assays, we are developing a certified reference material (CRM) for calibrating human genomic DNA working standards. To enable sharing information over time and place, CRMs must provide accurate and stable values that are metrologically traceable to a common reference. We have shown that droplet digital PCR (ddPCR) limiting dilution end-point measurements of the concentration of DNA copies per volume of sample can be traceably linked to the International System of Units (SI). Unlike values assigned using conventional relationships between ultraviolet absorbance and DNA mass concentration, entity-based ddPCR measurements are expected to be stable over time. However, the forensic community expects DNA quantity to be stated in terms of mass concentration rather than entity concentration. The transformation can be accomplished given SI-traceable values and uncertainties for the number of nucleotide bases per human haploid genome equivalent (HHGE) and the average molar mass of a nucleotide monomer in the DNA polymer. This report presents the considerations required to establish the metrological traceability of ddPCR-based mass concentration estimates of human nuclear DNA. Graphical abstract The roots of metrological traceability for human nuclear DNA mass concentration results. Values for the factors in blue must be established experimentally. Values for the factors in red have been established from authoritative source materials. HHGE stands for "haploid human genome equivalent"; there are two HHGE per diploid human genome.

  2. Application of the Reference Method Isotope Dilution Gas Chromatography Mass Spectrometry (ID/GC/MS) to Establish Metrological Traceability for Calibration and Control of Blood Glucose Test Systems

    PubMed Central

    Andreis, Elisabeth; Küllmer, Kai

    2014-01-01

    Self-monitoring of blood glucose (BG) by means of handheld BG systems is a cornerstone in diabetes therapy. The aim of this article is to describe a procedure with proven traceability for calibration and evaluation of BG systems to guarantee reliable BG measurements. Isotope dilution gas chromatography mass spectrometry (ID/GC/MS) is a method that fulfills all requirements to be used in a higher-order reference measurement procedure. However, this method is not applicable for routine measurements because of the time-consuming sample preparation. A hexokinase method with perchloric acid (PCA) sample pretreatment is used in a measurement procedure for such purposes. This method is directly linked to the ID/GC/MS method by calibration with a glucose solution that has an ID/GC/MS-determined target value. BG systems are calibrated with whole blood samples. The glucose levels in such samples are analyzed by this ID/GC/MS-linked hexokinase method to establish traceability to higher-order reference material. For method comparison, the glucose concentrations in 577 whole blood samples were measured using the PCA-hexokinase method and the ID/GC/MS method; this resulted in a mean deviation of 0.1%. The mean deviation between BG levels measured in >500 valid whole blood samples with BG systems and the ID/GC/MS was 1.1%. BG systems allow a reliable glucose measurement if a true reference measurement procedure, with a noninterrupted traceability chain using ID/GC/MS linked hexokinase method for calibration of BG systems, is implemented. Systems should be calibrated by means of a traceable and defined measurement procedure to avoid bias. PMID:24876614

  3. Nomenclature and traceability debate for biosimilars: small-molecule surrogates lend support for distinguishable nonproprietary names.

    PubMed

    Chao, Jingdong; Skup, Martha; Alexander, Emily; Tundia, Namita; Macaulay, Dendy; Wu, Eric; Mulani, Parvez

    2015-03-01

    The purpose of the present study was to investigate the traceability of adverse events (AEs) for branded and generic drugs with identical nonproprietary names and to consider potential implications for the traceability of AEs for branded and biosimilar biologics. Adverse event reports in the Food and Drug Administration AE Reporting System (FAERS) were compared with those in a commercial insurance claims database (Truven Health MarketScan(®)) for 2 drugs (levetiracetam and enoxaparin sodium) with manufacturing or prescribing considerations potentially analogous to those of some biosimilars. Monthly rates of branded- and generic-attributed AEs were estimated pre- and post-generic entry. Post-entry branded-to-generic AE relative rate ratios were calculated. In FAERS, monthly AE rate ratios during the post-generic period showed a pattern in which AE rates for the branded products were greater than for the generic products. Differences in rates of brand- and generic-attributed AEs were statistically significant for both study drugs; the AE rate for the branded products peaked at approximately 10 times that of the generic levetiracetam products and approximately 4 times that of the generic enoxaparin sodium products. In contrast, monthly ratios for the MarketScan data were relatively constant over time. Use of the same nonproprietary name for generic and branded products may contribute to poor traceability of AEs reported in the FAERS database due to the significant misattribution of AEs to branded products (when those AEs were in fact associated with patient use of generic products). To ensure accurate and robust safety surveillance and traceability for biosimilar products in the United States, improved product identification mechanisms, such as related but distinguishable nonproprietary names for biosimilars and reference biologics, should be considered.

  4. A methodology for obtaining on-orbit SI-traceable spectral radiance measurements in the thermal infrared

    NASA Astrophysics Data System (ADS)

    Dykema, John A.; Anderson, James G.

    2006-06-01

    A methodology to achieve spectral thermal radiance measurements from space with demonstrable on-orbit traceability to the International System of Units (SI) is described. This technique results in measurements of infrared spectral radiance R(\\tilde {\\upsilon }) , with spectral index \\tilde {\\upsilon } in cm-1, with a relative combined uncertainty u_c[R(\\tilde {\\upsilon })] of 0.0015 (k = 1) for the average mid-infrared radiance emitted by the Earth. This combined uncertainty, expressed in brightness temperature units, is equivalent to ±0.1 K at 250 K at 750 cm-1. This measurement goal is achieved by utilizing a new method for infrared scale realization combined with an instrument design optimized to minimize component uncertainties and admit tests of radiometric performance. The SI traceability of the instrument scale is established by evaluation against source-based and detector-based infrared scales in defined laboratory protocols before launch. A novel strategy is executed to ensure fidelity of on-orbit calibration to the pre-launch scale. This strategy for on-orbit validation relies on the overdetermination of instrument calibration. The pre-launch calibration against scales derived from physically independent paths to the base SI units provides the foundation for a critical analysis of the overdetermined on-orbit calibration to establish an SI-traceable estimate of the combined measurement uncertainty. Redundant calibration sources and built-in diagnostic tests to assess component measurement uncertainties verify the SI traceability of the instrument calibration over the mission lifetime. This measurement strategy can be realized by a practical instrument, a prototype Fourier-transform spectrometer under development for deployment on a small satellite. The measurement record resulting from the methodology described here meets the observational requirements for climate monitoring and climate model testing and improvement.

  5. Knowledge, attitudes and practices of traceability among livestock traders in south-western Nigeria: implications for sustainable livestock industry.

    PubMed

    Adesokan, Hezekiah K; Ocheja, Samuel E

    2014-01-01

    Livestock diseases and other animal health events are a threat to achieving sustainable livestock industry. The knowledge of trace-back and the practice of providing feedback on diseases encountered in slaughtered animals from the abattoir to the farm can help limit the spread as well as manage potential future incidents of such diseases. We assessed the knowledge, attitudes and practices of 200 willing livestock traders on traceability in Bodija Municipal Abattoir, south-western Nigeria. The results reveal that the majority of these traders had poor knowledge (79.5 %) and practices (74.0 %) of traceability, though 89.5 % demonstrated good attitudes. While 22.9 % knew that traceability could be an effective means to control diseases, only a lower proportion (9.0 %) knew the health status of the animals being purchased. Though 29.0 % reported the diseases encountered in their animals during slaughter to the farm, only 9.5 % followed up to ensure the farmers take steps at preventing further occurrence of the reported diseases. While age (p = 0.000; 0.014) and education (p = 0.000; 0.000) were both significant for good knowledge and attitudes, frequency of condemned cases (p = 0.000) and length of years in the trade (p = 0.004) were, respectively, significant for good knowledge and attitudes with none associated with practice. These poor levels of knowledge and practices of traceability are a threat to sustainable livestock industry, food security and human health; hence, there is an urgent need to institute national feedback mechanism on slaughtered animals in order to strengthen interventions against diseases at farm levels.

  6. SPIDER: Next Generation Chip Scale Imaging Sensor

    NASA Astrophysics Data System (ADS)

    Duncan, Alan; Kendrick, Rick; Thurman, Sam; Wuchenich, Danielle; Scott, Ryan P.; Yoo, S. J. B.; Su, Tiehui; Yu, Runxiang; Ogden, Chad; Proiett, Roberto

    The LM Advanced Technology Center and UC Davis are developing an Electro-Optical (EO) imaging sensor called SPIDER (Segmented Planar Imaging Detector for Electro-optical Reconnaissance) that provides a 10x to 100x size, weight, and power (SWaP) reduction alternative to the traditional bulky optical telescope and focal plane detector array. The substantial reductions in SWaP would reduce cost and/or provide higher resolution by enabling a larger aperture imager in a constrained volume. The SPIDER concept consists of thousands of direct detection white-light interferometers densely packed onto Photonic Integrated Circuits (PICs) to measure the amplitude and phase of the visibility function at spatial frequencies that span the full synthetic aperture. In other words, SPIDER would sample the object being imaged in the Fourier domain (i.e., spatial frequency domain), and then digitally reconstruct an image. The conventional approach for imaging interferometers requires complex mechanical delay lines to form the interference fringes. This results in designs that are not traceable to more than a few simultaneous spatial frequency measurements. SPIDER seeks to achieve this traceability by employing micron-=scale optical waveguides and nanophotonic structures fabricated on a PIC with micron-scale packing density to form the necessary interferometers. Prior LM IRAD and DARPA/NASA CRAD-funded SPIDER risk reduction experiments, design trades, and simulations have matured the SPIDER imager concept to a TRL 3 level. Current funding under the DARPA SPIDER Zoom program is maturing the underlying PIC technology for SPIDER to the TRL 4 level. This is done by developing and fabricating a second-generation PIC that is fully traceable to the multiple layers and low-power phase modulators required for higher-dimension waveguide arrays that are needed for higher field-of-view sensors. Our project also seeks to extend the SPIDER concept to add a zoom capability that would provide simultaneous low-resolution, large field-of-view and steerable high-resolution, narrow field-of-view imaging modes. A proof of concept demo is being designed to validate this capability. Finally, data collected by this project would be used to benchmark and increase the fidelity of our SPIDER image simulations and enhance our ability to predict the performance of existing and future SPIDER sensor design variations. These designs and their associated performance characteristics could then be evaluated as candidates for future mission opportunities to identify specific transition paths. This paper provides an overview of performance data on the first-generation PIC for SPIDER developed under DARPA SeeMe program funding. We provide a design description of the SPICER Zoom imaging sensor and the second-generation PIC (high- and low-resolution versions) currently under development on the DARPA SPIDER Zoom effort. Results of performance simulations and design trades are presented. Unique low-cost payload applications for future SSA missions are also discussed.

  7. Comparison of infusion pumps calibration methods

    NASA Astrophysics Data System (ADS)

    Batista, Elsa; Godinho, Isabel; do Céu Ferreira, Maria; Furtado, Andreia; Lucas, Peter; Silva, Claudia

    2017-12-01

    Nowadays, several types of infusion pump are commonly used for drug delivery, such as syringe pumps and peristaltic pumps. These instruments present different measuring features and capacities according to their use and therapeutic application. In order to ensure the metrological traceability of these flow and volume measuring equipment, it is necessary to use suitable calibration methods and standards. Two different calibration methods can be used to determine the flow error of infusion pumps. One is the gravimetric method, considered as a primary method, commonly used by National Metrology Institutes. The other calibration method, a secondary method, relies on an infusion device analyser (IDA) and is typically used by hospital maintenance offices. The suitability of the IDA calibration method was assessed by testing several infusion instruments at different flow rates using the gravimetric method. In addition, a measurement comparison between Portuguese Accredited Laboratories and hospital maintenance offices was performed under the coordination of the Portuguese Institute for Quality, the National Metrology Institute. The obtained results were directly related to the used calibration method and are presented in this paper. This work has been developed in the framework of the EURAMET projects EMRP MeDD and EMPIR 15SIP03.

  8. Implementing traceability using particle randomness-based textile printed tags

    NASA Astrophysics Data System (ADS)

    Agrawal, T. K.; Koehl, L.; Campagne, C.

    2017-10-01

    This article introduces a random particle-based traceability tag for textiles. The proposed tag not only act as a unique signature for the corresponding textile product but also possess the features such as easy to manufacture and hard to copy. It seeks applications in brand authentication and traceability in textile and clothing (T&C) supply chain. A prototype has been developed by screen printing process, in which micron-scale particles were mixed with the printing paste and printed on cotton fabrics to attain required randomness. To encode the randomness, the image of the developed tag was taken and analyzed using image processing. The randomness of the particles acts as a product key or unique signature which is required to decode the tag. Finally, washing and abrasion resistance tests were conducted to check the durability of the printed tag.

  9. [Preliminary studies on critical control point of traceability system in wolfberry].

    PubMed

    Liu, Sai; Xu, Chang-Qing; Li, Jian-Ling; Lin, Chen; Xu, Rong; Qiao, Hai-Li; Guo, Kun; Chen, Jun

    2016-07-01

    As a traditional Chinese medicine, wolfberry (Lycium barbarum) has a long cultivation history and a good industrial development foundation. With the development of wolfberry production, the expansion of cultivation area and the increased attention of governments and consumers on food safety, the quality and safety requirement of wolfberry is higher demanded. The quality tracing and traceability system of production entire processes is the important technology tools to protect the wolfberry safety, and to maintain sustained and healthy development of the wolfberry industry. Thus, this article analyzed the wolfberry quality management from the actual situation, the safety hazard sources were discussed according to the HACCP (hazard analysis and critical control point) and GAP (good agricultural practice for Chinese crude drugs), and to provide a reference for the traceability system of wolfberry. Copyright© by the Chinese Pharmaceutical Association.

  10. Traceability in stem cell research: from participant sample to induced pluripotent stem cell and back.

    PubMed

    Morrison, Michael; Moraia, Linda Briceño; Steele, Jane C

    2016-01-01

    This paper describes a traceability system developed for the Stem cells for Biological Assays of Novel drugs and prediCtive toxiCology consortium. The system combines records and labels that to biological material across geographical locations and scientific processes from sample donation to induced pluripotent stem cell line. The labeling system uses a unique identification number to link every aliquot of sample at every stage of the reprogramming pathway back to the original donor. Only staff at the clinical recruitment site can reconnect the unique identification number to the identifying details of a specific donor. This ensures the system meets ethical and legal requirements for protecting privacy while allowing full traceability of biological material. The system can be adapted to other projects and for use with different primary sample types.

  11. Services of the CDRH X-ray calibration laboratory and their traceability to National Standards

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cerra, F.; Heaton, H.T.

    The X-ray Calibration Laboratory (XCL) of the Center for Devices and Radiological Health (CDRH) provides calibration services for the Food and Drug Administration (FDA). The instruments calibrated are used by FDA and contract state inspectors to verify compliance with federal x-ray performance standards and for national surveys of x-ray trends. In order to provide traceability of measurements, the CDRH XCL is accredited by the National Voluntary Laboratory Accreditation Program (NVLAP) for reference, diagnostic, and x-ray survey instrument calibrations. In addition to these accredited services, the CDRH XCL also calibrates non-invasive kVp meters in single- and three-phase x-ray beams, and thermoluminescentmore » dosimeter (TLD) chips used to measure CT beam profiles. The poster illustrates these services and shows the traceability links back to the National Standards.« less

  12. Traceable measurements of small forces and local mechanical properties

    NASA Astrophysics Data System (ADS)

    Campbellová, Anna; Valtr, Miroslav; Zůda, Jaroslav; Klapetek, Petr

    2011-09-01

    Measurement of local mechanical properties is an important topic in the fields of nanoscale device fabrication, thin film deposition and composite material development. Nanoindentation instruments are commonly used to study hardness and related mechanical properties at the nanoscale. However, traceability and uncertainty aspects of the measurement process often remain left aside. In this contribution, the use of a commercial nanoindentation instrument for metrology purposes will be discussed. Full instrument traceability, provided using atomic force microscope cantilevers and a mass comparator (normal force), interferometer (depth) and atomic force microscope (area function) is described. The uncertainty of the loading/unloading curve measurements will be analyzed and the resulting uncertainties for quantities, that are computed from loading curves such as hardness or elastic modulus, are studied. For this calculation a combination of uncertainty propagation law and Monte Carlo uncertainty evaluations are used.

  13. Traceable Calibration, Performance Metrics, and Uncertainty Estimates of Minirhizotron Digital Imagery for Fine-Root Measurements

    PubMed Central

    Roberti, Joshua A.; SanClements, Michael D.; Loescher, Henry W.; Ayres, Edward

    2014-01-01

    Even though fine-root turnover is a highly studied topic, it is often poorly understood as a result of uncertainties inherent in its sampling, e.g., quantifying spatial and temporal variability. While many methods exist to quantify fine-root turnover, use of minirhizotrons has increased over the last two decades, making sensor errors another source of uncertainty. Currently, no standardized methodology exists to test and compare minirhizotron camera capability, imagery, and performance. This paper presents a reproducible, laboratory-based method by which minirhizotron cameras can be tested and validated in a traceable manner. The performance of camera characteristics was identified and test criteria were developed: we quantified the precision of camera location for successive images, estimated the trueness and precision of each camera's ability to quantify root diameter and root color, and also assessed the influence of heat dissipation introduced by the minirhizotron cameras and electrical components. We report detailed and defensible metrology analyses that examine the performance of two commercially available minirhizotron cameras. These cameras performed differently with regard to the various test criteria and uncertainty analyses. We recommend a defensible metrology approach to quantify the performance of minirhizotron camera characteristics and determine sensor-related measurement uncertainties prior to field use. This approach is also extensible to other digital imagery technologies. In turn, these approaches facilitate a greater understanding of measurement uncertainties (signal-to-noise ratio) inherent in the camera performance and allow such uncertainties to be quantified and mitigated so that estimates of fine-root turnover can be more confidently quantified. PMID:25391023

  14. Robust Informatics Infrastructure Required For ICME: Combining Virtual and Experimental Data

    NASA Technical Reports Server (NTRS)

    Arnold, Steven M.; Holland, Frederic A. Jr.; Bednarcyk, Brett A.

    2014-01-01

    With the increased emphasis on reducing the cost and time to market of new materials, the need for robust automated materials information management system(s) enabling sophisticated data mining tools is increasing, as evidenced by the emphasis on Integrated Computational Materials Engineering (ICME) and the recent establishment of the Materials Genome Initiative (MGI). This need is also fueled by the demands for higher efficiency in material testing; consistency, quality and traceability of data; product design; engineering analysis; as well as control of access to proprietary or sensitive information. Further, the use of increasingly sophisticated nonlinear, anisotropic and or multi-scale models requires both the processing of large volumes of test data and complex materials data necessary to establish processing-microstructure-property-performance relationships. Fortunately, material information management systems have kept pace with the growing user demands and evolved to enable: (i) the capture of both point wise data and full spectra of raw data curves, (ii) data management functions such as access, version, and quality controls;(iii) a wide range of data import, export and analysis capabilities; (iv) data pedigree traceability mechanisms; (v) data searching, reporting and viewing tools; and (vi) access to the information via a wide range of interfaces. This paper discusses key principles for the development of a robust materials information management system to enable the connections at various length scales to be made between experimental data and corresponding multiscale modeling toolsets to enable ICME. In particular, NASA Glenn's efforts towards establishing such a database for capturing constitutive modeling behavior for both monolithic and composites materials

  15. Effective Materials Property Information Management for the 21st Century

    NASA Technical Reports Server (NTRS)

    Ren, Weiju; Cebon, David; Arnold, Steve

    2009-01-01

    This paper discusses key principles for the development of materials property information management software systems. There are growing needs for automated materials information management in various organizations. In part these are fueled by the demands for higher efficiency in material testing, product design and engineering analysis. But equally important, organizations are being driven by the need for consistency, quality and traceability of data, as well as control of access to sensitive information such as proprietary data. Further, the use of increasingly sophisticated nonlinear, anisotropic and multi-scale engineering analyses requires both processing of large volumes of test data for development of constitutive models and complex materials data input for Computer-Aided Engineering (CAE) software. And finally, the globalization of economy often generates great needs for sharing a single "gold source" of materials information between members of global engineering teams in extended supply chains. Fortunately, material property management systems have kept pace with the growing user demands and evolved to versatile data management systems that can be customized to specific user needs. The more sophisticated of these provide facilities for: (i) data management functions such as access, version, and quality controls; (ii) a wide range of data import, export and analysis capabilities; (iii) data "pedigree" traceability mechanisms; (iv) data searching, reporting and viewing tools; and (v) access to the information via a wide range of interfaces. In this paper the important requirements for advanced material data management systems, future challenges and opportunities such as automated error checking, data quality characterization, identification of gaps in datasets, as well as functionalities and business models to fuel database growth and maintenance are discussed.

  16. Traceability validation of a high speed short-pulse testing method used in LED production

    NASA Astrophysics Data System (ADS)

    Revtova, Elena; Vuelban, Edgar Moreno; Zhao, Dongsheng; Brenkman, Jacques; Ulden, Henk

    2017-12-01

    Industrial processes of LED (light-emitting diode) production include LED light output performance testing. Most of them are monitored and controlled by optically, electrically and thermally measuring LEDs by high speed short-pulse measurement methods. However, these are not standardized and a lot of information is proprietary that it is impossible for third parties, such as NMIs, to trace and validate. It is known, that these techniques have traceability issue and metrological inadequacies. Often due to these, the claimed performance specifications of LEDs are overstated, which consequently results to manufacturers experiencing customers' dissatisfaction and a large percentage of failures in daily use of LEDs. In this research a traceable setup is developed to validate one of the high speed testing techniques, investigate inadequacies and work out the traceability issues. A well-characterised short square pulse of 25 ms is applied to chip-on-board (CoB) LED modules to investigate the light output and colour content. We conclude that the short-pulse method is very efficient in case a well-defined electrical current pulse is applied and the stabilization time of the device is "a priori" accurately determined. No colour shift is observed. The largest contributors to the measurement uncertainty include badly-defined current pulse and inaccurate calibration factor.

  17. A study of the factors that influence consumer attitudes toward beef products using the conjoint market analysis tool.

    PubMed

    Mennecke, B E; Townsend, A M; Hayes, D J; Lonergan, S M

    2007-10-01

    This study utilizes an analysis technique commonly used in marketing, the conjoint analysis method, to examine the relative utilities of a set of beef steak characteristics considered by a national sample of 1,432 US consumers, as well as additional localized samples representing undergraduate students at a business college and in an animal science department. The analyses indicate that among all respondents, region of origin is by far the most important characteristic; this is followed by animal breed, traceability, animal feed, and beef quality. Alternatively, the cost of cut, farm ownership, the use (or nonuse) of growth promoters, and whether the product is guaranteed tender were the least important factors. Results for animal science undergraduates are similar to the aggregate results, except that these students emphasized beef quality at the expense of traceability and the nonuse of growth promoters. Business students also emphasized region of origin but then emphasized traceability and cost. The ideal steak for the national sample is from a locally produced, choice Angus fed a mixture of grain and grass that is traceable to the farm of origin. If the product was not produced locally, respondents indicated that their preferred production states are, in order from most to least preferred, Iowa, Texas, Nebraska, and Kansas.

  18. Thermodynamic Temperature of High-Temperature Fixed Points Traceable to Blackbody Radiation and Synchrotron Radiation

    NASA Astrophysics Data System (ADS)

    Wähmer, M.; Anhalt, K.; Hollandt, J.; Klein, R.; Taubert, R. D.; Thornagel, R.; Ulm, G.; Gavrilov, V.; Grigoryeva, I.; Khlevnoy, B.; Sapritsky, V.

    2017-10-01

    Absolute spectral radiometry is currently the only established primary thermometric method for the temperature range above 1300 K. Up to now, the ongoing improvements of high-temperature fixed points and their formal implementation into an improved temperature scale with the mise en pratique for the definition of the kelvin, rely solely on single-wavelength absolute radiometry traceable to the cryogenic radiometer. Two alternative primary thermometric methods, yielding comparable or possibly even smaller uncertainties, have been proposed in the literature. They use ratios of irradiances to determine the thermodynamic temperature traceable to blackbody radiation and synchrotron radiation. At PTB, a project has been established in cooperation with VNIIOFI to use, for the first time, all three methods simultaneously for the determination of the phase transition temperatures of high-temperature fixed points. For this, a dedicated four-wavelengths ratio filter radiometer was developed. With all three thermometric methods performed independently and in parallel, we aim to compare the potential and practical limitations of all three methods, disclose possibly undetected systematic effects of each method and thereby confirm or improve the previous measurements traceable to the cryogenic radiometer. This will give further and independent confidence in the thermodynamic temperature determination of the high-temperature fixed point's phase transitions.

  19. Traceable calibration and demonstration of a portable dynamic force transfer standard

    NASA Astrophysics Data System (ADS)

    Vlajic, Nicholas; Chijioke, Ako

    2017-08-01

    In general, the dynamic sensitivity of a force transducer depends upon the mechanical system in which it is used. This dependence serves as motivation to develop a dynamic force transfer standard, which can be used to calibrate an application transducer in situ. In this work, we SI-traceably calibrate a hand-held force transducer, namely an impact hammer, by using a mass suspended from a thin line which is cut to produce a known dynamic force in the form of a step function. We show that this instrument is a promising candidate as a transfer standard, since its dynamic response has small variance between different users. This calibrated transfer standard is then used to calibrate a secondary force transducer in an example application setting. The combined standard uncertainty (k  =  2) in the calibration of the transfer standard was determined to be 2.1% or less, up to a bandwidth of 5 kHz. The combined standard uncertainty (k  =  2) in the performed transfer calibration was less than 4%, up to 3 kHz. An advantage of the transfer calibration framework presented here, is that the transfer standard can be used to transfer SI-traceable calibrations without the use of any SI-traceable voltage metrology instrumentation.

  20. Establishing the traceability of a uranyl nitrate solution to a standard reference material

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jackson, C.H.; Clark, J.P.

    1978-01-01

    A uranyl nitrate solution for use as a Working Calibration and Test Material (WCTM) was characterized, using a statistically designed procedure to document traceability to National Bureau of Standards Reference Material (SPM-960). A Reference Calibration and Test Material (PCTM) was prepared from SRM-960 uranium metal to approximate the acid and uranium concentration of the WCTM. This solution was used in the characterization procedure. Details of preparing, handling, and packaging these solutions are covered. Two outside laboratories, each having measurement expertise using a different analytical method, were selected to measure both solutions according to the procedure for characterizing the WCTM. Twomore » different methods were also used for the in-house characterization work. All analytical results were tested for statistical agreement before the WCTM concentration and limit of error values were calculated. A concentration value was determined with a relative limit of error (RLE) of approximately 0.03% which was better than the target RLE of 0.08%. The use of this working material eliminates the expense of using SRMs to fulfill traceability requirements for uranium measurements on this type material. Several years' supply of uranyl nitrate solution with NBS traceability was produced. The cost of this material was less than 10% of an equal quantity of SRM-960 uranium metal.« less

  1. Measurement of Lipid Accumulation in Chlorella vulgaris via Flow Cytometry and Liquid-State ¹H NMR Spectroscopy for Development of an NMR-Traceable Flow Cytometry Protocol

    PubMed Central

    Bono Jr., Michael S.; Garcia, Ravi D.; Sri-Jayantha, Dylan V.; Ahner, Beth A.; Kirby, Brian J.

    2015-01-01

    In this study, we cultured Chlorella vulgaris cells with a range of lipid contents, induced via nitrogen starvation, and characterized them via flow cytometry, with BODIPY 505/515 as a fluorescent lipid label, and liquid-state 1H NMR spectroscopy. In doing so, we demonstrate the utility of calibrating flow cytometric measurements of algal lipid content using triacylglyceride (TAG, also known as triacylglycerol or triglyceride) content per cell as measured via quantitative 1H NMR. Ensemble-averaged fluorescence of BODIPY-labeled cells was highly correlated with average TAG content per cell measured by bulk NMR, with a linear regression yielding a linear fit with r 2 = 0.9974. This correlation compares favorably to previous calibrations of flow cytometry protocols to lipid content measured via extraction, and calibration by NMR avoids the time and complexity that is generally required for lipid quantitation via extraction. Flow cytometry calibrated to a direct measurement of TAG content can be used to investigate the distribution of lipid contents for cells within a culture. Our flow cytometry measurements showed that Chlorella vulgaris cells subjected to nitrogen limitation exhibited higher mean lipid content but a wider distribution of lipid content that overlapped the relatively narrow distribution of lipid content for replete cells, suggesting that nitrogen limitation induces lipid accumulation in only a subset of cells. Calibration of flow cytometry protocols using direct in situ measurement of TAG content via NMR will facilitate rapid development of more precise flow cytometry protocols, enabling investigation of algal lipid accumulation for development of more productive algal biofuel feedstocks and cultivation protocols. PMID:26267664

  2. Measurement of lipid accumulation in Chlorella vulgaris via flow cytometry and liquid-state ¹H NMR spectroscopy for development of an NMR-traceable flow cytometry protocol.

    PubMed

    Bono, Michael S; Garcia, Ravi D; Sri-Jayantha, Dylan V; Ahner, Beth A; Kirby, Brian J

    2015-01-01

    In this study, we cultured Chlorella vulgaris cells with a range of lipid contents, induced via nitrogen starvation, and characterized them via flow cytometry, with BODIPY 505/515 as a fluorescent lipid label, and liquid-state 1H NMR spectroscopy. In doing so, we demonstrate the utility of calibrating flow cytometric measurements of algal lipid content using triacylglyceride (TAG, also known as triacylglycerol or triglyceride) content per cell as measured via quantitative 1H NMR. Ensemble-averaged fluorescence of BODIPY-labeled cells was highly correlated with average TAG content per cell measured by bulk NMR, with a linear regression yielding a linear fit with r2 = 0.9974. This correlation compares favorably to previous calibrations of flow cytometry protocols to lipid content measured via extraction, and calibration by NMR avoids the time and complexity that is generally required for lipid quantitation via extraction. Flow cytometry calibrated to a direct measurement of TAG content can be used to investigate the distribution of lipid contents for cells within a culture. Our flow cytometry measurements showed that Chlorella vulgaris cells subjected to nitrogen limitation exhibited higher mean lipid content but a wider distribution of lipid content that overlapped the relatively narrow distribution of lipid content for replete cells, suggesting that nitrogen limitation induces lipid accumulation in only a subset of cells. Calibration of flow cytometry protocols using direct in situ measurement of TAG content via NMR will facilitate rapid development of more precise flow cytometry protocols, enabling investigation of algal lipid accumulation for development of more productive algal biofuel feedstocks and cultivation protocols.

  3. SI-traceable standards for atmospheric monitoring of halogenated gases

    NASA Astrophysics Data System (ADS)

    Guillevic, Myriam; Wyss, Simon A.; Pascale, Céline; Vollmer, Martin K.; Niederhauser, Bernhard; Reimann, Stefan

    2017-04-01

    To support atmospheric monitoring of greenhouse gases and in particular halogenated gases, we have developed a method to produce reference gas mixtures at nmol/mol (ppb) to pmol/mol levels (ppt). This method is dynamic and SI-traceable. This work is conducted in the framework of the EMRP projects HIGHGAS and KEY-VOCs as well as METAS' AtmoChemECV project. The method has been already applied to HFC-125 (pentafluoroethane, widely used in air conditioners), HFC-1234yf (2,3,3,3-tetrafluoropropene, a car air conditioner fluid of growing importance) and SF6 (insulant in electric switch-gears). It is currently being extended to HCFC-132b and CFC-13. It is particularly suitable for gas species and/or concentration ranges that are not stable in cylinders and it can be applied to a large variety of molecules related to air pollution and climate change (e.g., NO2, volatile organic compounds such as BTEX, NH3, water vapour at ppm level, CFCs, HCFCs, HFCs). The expanded uncertainty is less than 3 % (95 % confidence interval or k=2). The generation process is composed of four successive steps. In the first step the matrix gas, nitrogen or synthetic air is purified. Then this matrix gas is spiked with the pure substance, using a permeation device which contains a few grams of the pure substance (e.g., HFC-125) in the liquid form and loses it linearly over time by permeation through a membrane. This mass loss is precisely calibrated in our lab in Bern, using a magnetic suspension balance. In a third step the desired concentration is reached by dilution of the high concentration mixture exiting the permeation chamber with a chosen flow of the matrix gas in one or two subsequent dilution steps. All flows are piloted by mass flow controllers. All parts in contact with the gas mixture - including the balance - are passivated using coated surfaces, to reduce adsorption/desorption processes as much as possible. In the last step the mixture can be i) directly used to calibrate an analyser, ii) sampled on sorbent tubes or iii) pressurized into Silconert2000-coated stainless steel cylinders by cryo-filling. We focus here on standards made for the gases HFC-125 and HFC-1234yf. We present here the method, the uncertainty budget as well as first results of intercomparisons to other references.

  4. Drag reduction in a turbulent channel flow using a passivity-based approach

    NASA Astrophysics Data System (ADS)

    Heins, Peter; Jones, Bryn; Sharma, Atul

    2013-11-01

    A new active feedback control strategy for attenuating perturbation energy in a turbulent channel flow is presented. Using a passivity-based approach, a controller synthesis procedure has been devised which is capable of making the linear dynamics of a channel flow as close to passive as is possible given the limitations on sensing and actuation. A controller that is capable of making the linearized flow passive is guaranteed to globally stabilize the true flow. The resulting controller is capable of greatly restricting the amount of turbulent energy that the nonlinearity can feed back into the flow. DNS testing of a controller using wall-sensing of streamwise and spanwise shear stress and actuation via wall transpiration acting upon channel flows with Reτ = 100 - 250 showed significant reductions in skin-friction drag.

  5. ASRM case insulation design and development

    NASA Astrophysics Data System (ADS)

    Bell, Matthew S.; Tam, William F. S.

    1992-10-01

    This paper describes the achievements made on the Advanced Solid Rocket Motor (ASRM) case insulation design and development program. The ASRM case insulation system described herein protects the metal case and joints from direct radiation and hot gas impingement. Critical failure of solid rocket systems is often traceable to failure of the insulation design. The wide ranging accomplishments included the development of a nonasbestos insulation material for ASRM that replaced the existing Redesigned Solid Rocket Motor (RSRM) asbestos-filled nitrile butadiene rubber (NBR) along with a performance gain of 300 pounds, and improved reliability of all the insulation joint designs, i.e., segmented case joint, case-to-nozzle and case-to-igniter joint. The insulation process development program included the internal stripwinding process. This process advancement allowed Aerojet to match to exceed the capability of other propulsion companies.

  6. Recent Surface Reflectance Measurement Campaigns with Emphasis on Best Practices, SI Traceability and Uncertainty Estimation

    NASA Technical Reports Server (NTRS)

    Helder, Dennis; Thome, Kurtis John; Aaron, Dave; Leigh, Larry; Czapla-Myers, Jeff; Leisso, Nathan; Biggar, Stuart; Anderson, Nik

    2012-01-01

    A significant problem facing the optical satellite calibration community is limited knowledge of the uncertainties associated with fundamental measurements, such as surface reflectance, used to derive satellite radiometric calibration estimates. In addition, it is difficult to compare the capabilities of calibration teams around the globe, which leads to differences in the estimated calibration of optical satellite sensors. This paper reports on two recent field campaigns that were designed to isolate common uncertainties within and across calibration groups, particularly with respect to ground-based surface reflectance measurements. Initial results from these efforts suggest the uncertainties can be as low as 1.5% to 2.5%. In addition, methods for improving the cross-comparison of calibration teams are suggested that can potentially reduce the differences in the calibration estimates of optical satellite sensors.

  7. CoSEC: Connecting Living With a Star Research

    NASA Astrophysics Data System (ADS)

    Hurlburt, N.; Freeland, S.; Bose, P.; Zimdars, A.; Slater, G.

    2006-12-01

    The Collaborative Sun-Earth Connector (CoSEC) provide the means for heliophysics researchers to compose the data sources and processing services published by their peers into processing workflows that reliably generate publication-worthy data. It includes: composition of computational and data services into easy-to- read workflows with data quality and version traceability; straightforward translation of existing services into workflow components, and advertisement of those components to other members of the CoSEC community; annotation of published services with functional attributes to enable discovery of capabilities required by particular workflows and identify peer subgroups in the CoSEC community; and annotation of published services with nonfunctional attributes to enable selection on the basis of quality of service (QoS). We present an overview and demonstration of the CoSEC system, discuss applications, the lessons learned and future developments.

  8. ASRM case insulation design and development

    NASA Technical Reports Server (NTRS)

    Bell, Matthew S.; Tam, William F. S.

    1992-01-01

    This paper describes the achievements made on the Advanced Solid Rocket Motor (ASRM) case insulation design and development program. The ASRM case insulation system described herein protects the metal case and joints from direct radiation and hot gas impingement. Critical failure of solid rocket systems is often traceable to failure of the insulation design. The wide ranging accomplishments included the development of a nonasbestos insulation material for ASRM that replaced the existing Redesigned Solid Rocket Motor (RSRM) asbestos-filled nitrile butadiene rubber (NBR) along with a performance gain of 300 pounds, and improved reliability of all the insulation joint designs, i.e., segmented case joint, case-to-nozzle and case-to-igniter joint. The insulation process development program included the internal stripwinding process. This process advancement allowed Aerojet to match to exceed the capability of other propulsion companies.

  9. Metrological Characterization of the Vickers Hardness Primary Standard Machine Established at CSIR-NPL

    NASA Astrophysics Data System (ADS)

    Titus, S. Seelakumar; Vikram; Girish; Jain, Sushil Kumar

    2018-06-01

    CSIR-National Physical Laboratory (CSIR-NPL) is the National Metrological Institute (NMI) of India, which has the mandate for the realization of SI units of measurements and dissemination of the same to the user organizations. CSIR-NPL has established a hardness standardizing machine for realizing the Vickers hardness scale as per ISO 6507-3 standard for providing national traceability in hardness measurement. Direct verification of the machine has been carried out by measuring the uncertainty in the generated force, the indenter geometry and the indentation measuring system. From these measurements, it is found that the machine exhibits a calibration and measurement capability (CMC) of ±1.5% for HV1-HV3 scales and ±1.0% for HV5-HV50 scales and ±0.8% for HV100 scale.

  10. The European nanometrology landscape.

    PubMed

    Leach, Richard K; Boyd, Robert; Burke, Theresa; Danzebrink, Hans-Ulrich; Dirscherl, Kai; Dziomba, Thorsten; Gee, Mark; Koenders, Ludger; Morazzani, Valérie; Pidduck, Allan; Roy, Debdulal; Unger, Wolfgang E S; Yacoot, Andrew

    2011-02-11

    This review paper summarizes the European nanometrology landscape from a technical perspective. Dimensional and chemical nanometrology are discussed first as they underpin many of the developments in other areas of nanometrology. Applications for the measurement of thin film parameters are followed by two of the most widely relevant families of functional properties: measurement of mechanical and electrical properties at the nanoscale. Nanostructured materials and surfaces, which are seen as key materials areas having specific metrology challenges, are covered next. The final section describes biological nanometrology, which is perhaps the most interdisciplinary applications area, and presents unique challenges. Within each area, a review is provided of current status, the capabilities and limitations of current techniques and instruments, and future directions being driven by emerging industrial measurement requirements. Issues of traceability, standardization, national and international programmes, regulation and skills development will be discussed in a future paper.

  11. The European nanometrology landscape

    NASA Astrophysics Data System (ADS)

    Leach, Richard K.; Boyd, Robert; Burke, Theresa; Danzebrink, Hans-Ulrich; Dirscherl, Kai; Dziomba, Thorsten; Gee, Mark; Koenders, Ludger; Morazzani, Valérie; Pidduck, Allan; Roy, Debdulal; Unger, Wolfgang E. S.; Yacoot, Andrew

    2011-02-01

    This review paper summarizes the European nanometrology landscape from a technical perspective. Dimensional and chemical nanometrology are discussed first as they underpin many of the developments in other areas of nanometrology. Applications for the measurement of thin film parameters are followed by two of the most widely relevant families of functional properties: measurement of mechanical and electrical properties at the nanoscale. Nanostructured materials and surfaces, which are seen as key materials areas having specific metrology challenges, are covered next. The final section describes biological nanometrology, which is perhaps the most interdisciplinary applications area, and presents unique challenges. Within each area, a review is provided of current status, the capabilities and limitations of current techniques and instruments, and future directions being driven by emerging industrial measurement requirements. Issues of traceability, standardization, national and international programmes, regulation and skills development will be discussed in a future paper.

  12. Superior lithium storage performance using sequentially stacked MnO2/reduced graphene oxide composite electrodes.

    PubMed

    Kim, Sue Jin; Yun, Young Jun; Kim, Ki Woong; Chae, Changju; Jeong, Sunho; Kang, Yongku; Choi, Si-Young; Lee, Sun Sook; Choi, Sungho

    2015-04-24

    Hybrid nanostructures based on graphene and metal oxides hold great potential for use in high-performance electrode materials for next-generation lithium-ion batteries. Herein, a new strategy to fabricate sequentially stacked α-MnO2 /reduced graphene oxide composites driven by surface-charge-induced mutual electrostatic interactions is proposed. The resultant composite anode exhibits an excellent reversible charge/discharge capacity as high as 1100 mA h g(-1) without any traceable capacity fading, even after 100 cycles, which leads to a high rate capability electrode performance for lithium ion batteries. Thus, the proposed synthetic procedures guarantee a synergistic effect of multidimensional nanoscale media between one (metal oxide nanowire) and two dimensions (graphene sheet) for superior energy-storage electrodes. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Traceable calibration of photovoltaic reference cells using natural sunlight

    NASA Astrophysics Data System (ADS)

    Müllejans, H.; Zaaiman, W.; Pavanello, D.; Dunlop, E. D.

    2018-02-01

    At the European Solar Test Installation (ESTI) photovoltaic (PV) reference cells are calibrated traceably to SI units via the World Radiometric Reference (WRR) using natural sunlight. The Direct Sunlight Method (DSM) is described in detail and the latest measurement results and an updated uncertainty budget are reported. These PV reference cells then provide a practical means for measuring the irradiance of natural or simulated sunlight during the calibration of other PV devices.

  14. Meeting the measurement uncertainty and traceability requirements of ISO/AEC standard 17025 in chemical analysis.

    PubMed

    King, B

    2001-11-01

    The new laboratory accreditation standard, ISO/IEC 17025, reflects current thinking on good measurement practice by requiring more explicit and more demanding attention to a number of activities. These include client interactions, method validation, traceability, and measurement uncertainty. Since the publication of the standard in 1999 there has been extensive debate about its interpretation. It is the author's view that if good quality practices are already in place and if the new requirements are introduced in a manner that is fit for purpose, the additional work required to comply with the new requirements can be expected to be modest. The paper argues that the rigour required in addressing the issues should be driven by customer requirements and the factors that need to be considered in this regard are discussed. The issues addressed include the benefits, interim arrangements, specifying the analytical requirement, establishing traceability, evaluating the uncertainty and reporting the information.

  15. Tracing Asian Seabass Individuals to Single Fish Farms Using Microsatellites

    PubMed Central

    Yue, Gen Hua; Xia, Jun Hong; Liu, Peng; Liu, Feng; Sun, Fei; Lin, Grace

    2012-01-01

    Traceability through physical labels is well established, but it is not highly reliable as physical labels can be easily changed or lost. Application of DNA markers to the traceability of food plays an increasingly important role for consumer protection and confidence building. In this study, we tested the efficiency of 16 polymorphic microsatellites and their combinations for tracing 368 fish to four populations where they originated. Using the maximum likelihood and Bayesian methods, three most efficient microsatellites were required to assign over 95% of fish to the correct populations. Selection of markers based on the assignment score estimated with the software WHICHLOCI was most effective in choosing markers for individual assignment, followed by the selection based on the allele number of individual markers. By combining rapid DNA extraction, and high-throughput genotyping of selected microsatellites, it is possible to conduct routine genetic traceability with high accuracy in Asian seabass. PMID:23285169

  16. Consumer acceptance of a quick response (QR) code for the food traceability system: Application of an extended technology acceptance model (TAM).

    PubMed

    Kim, Yeong Gug; Woo, Eunju

    2016-07-01

    The objectives of this study are to apply the TAM using the addition of perceived information to individuals' behavioral intention to use the QR code for the food traceability system; and to determine the moderating effects of food involvement on the relationship between perceived information and perceived usefulness. Results from a survey of 420 respondents are analyzed using structural equation modeling. The study findings reveal that the extended TAM has a satisfactory fit to the data and that the underlying dimensions have a significant effect on consumers' intention to use the QR code for the food traceability system. In addition, food involvement plays a significant moderating function in the relationship between perceived information and perceived usefulness. The implications of this study for future research are discussed. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. A Collection Scheme for Tracing Information of Pig Safety Production

    NASA Astrophysics Data System (ADS)

    Luo, Qingyao; Xiong, Benhai; Yang, Liang

    This study takes one main production pattern of smallhold pig farming in Tianjin as a study prototype, deeply analyzes characters of informations about tracing inputs including vaccines,feeds,veterinary drugs and supervision test in pig farming, proposesinputs metadata, criteria for integrating inputs event and interface norms for data transmision, developes and completes identification of 2D ear tags and traceability information collection system of pig safety production based on mobile PDA. The system has implemented functions including setting and invalidate of 2D ear tags, collection of tracing inputs and supervision in the mobile PDA and finally integration of tracing events (the epidemic event,feed event,drug event and supervision event) on the traceability data center (server). The PDA information collection system has been applied for demonstration in Tianjin, the collection is simple, convenient and feasible. It could meet with requirements of traceability information system of pig safety production

  18. A new simplex chemometric approach to identify olive oil blends with potentially high traceability.

    PubMed

    Semmar, N; Laroussi-Mezghani, S; Grati-Kamoun, N; Hammami, M; Artaud, J

    2016-10-01

    Olive oil blends (OOBs) are complex matrices combining different cultivars at variable proportions. Although qualitative determinations of OOBs have been subjected to several chemometric works, quantitative evaluations of their contents remain poorly developed because of traceability difficulties concerning co-occurring cultivars. Around this question, we recently published an original simplex approach helping to develop predictive models of the proportions of co-occurring cultivars from chemical profiles of resulting blends (Semmar & Artaud, 2015). Beyond predictive model construction and validation, this paper presents an extension based on prediction errors' analysis to statistically define the blends with the highest predictability among all the possible ones that can be made by mixing cultivars at different proportions. This provides an interesting way to identify a priori labeled commercial products with potentially high traceability taking into account the natural chemical variability of different constitutive cultivars. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Systems Engineering for Space Exploration Medical Capabilities

    NASA Technical Reports Server (NTRS)

    Mindock, Jennifer; Reilly, Jeffrey; Urbina, Michelle; Hailey, Melinda; Rubin, David; Reyes, David; Hanson, Andrea; Burba, Tyler; McGuire, Kerry; Cerro, Jeffrey; hide

    2017-01-01

    Human exploration missions to beyond low Earth orbit destinations such as Mars will present significant new challenges to crew health management during a mission compared to current low Earth orbit operations. For the medical system, lack of consumable resupply, evacuation opportunities, and real-time ground support are key drivers toward greater autonomy. Recognition of the limited mission and vehicle resources available to carry out exploration missions motivates the Exploration Medical Capability (ExMC) Element's approach to enabling the necessary autonomy. The Element's work must integrate with the overall exploration mission and vehicle design efforts to successfully provide exploration medical capabilities. ExMC is applying systems engineering principles and practices to accomplish its integrative goals. This paper discusses the structured and integrative approach that is guiding the medical system technical development. Assumptions for the required levels of care on exploration missions, medical system guiding principles, and a Concept of Operations are early products that capture and clarify stakeholder expectations. Mobel-Based Systems Engineering techniques are then applied to define medical system behavior and architecture. Interfaces to other flight and ground systems, and within the medical system are identified and defined. Initial requirements and traceability are established, which sets the stage for identification of future technology development needs. An early approach for verification and validation, taking advantage of terrestrial and near-Earth exploration system analogs, is also defined to further guide system planning and development.

  20. Development of Traceable Phantoms for Improved Image Quantification in Positron Emission Tomography

    NASA Astrophysics Data System (ADS)

    Zimmerman, Brian

    2014-03-01

    Clinical trials for new drugs increasingly rely on imaging data to monitor patient response to the therapy being studied. In the case of radiopharmaceutical applications, imaging data are also used to estimate organ and tumor doses in order to arrive at the optimal dosage for safe and effective treatment. Positron Emission Tomography (PET) is one of the most commonly used imaging modalities for these types of applications. In large, multicenter trials it is crucial to minimize as much as possible the variability that arises due to use of different types of scanners and other instrumentation so that the biological response can be more readily evaluated. This can be achieved by ensuring that all the instruments are calibrated to a common standard and that their performance is continuously monitored throughout the trial. Maintaining links to a single standard also enables the comparability of data acquired on a heterogeneous collection of instruments in different clinical settings. As the standards laboratory for the United States, the National Institute of Standards and Technology (NIST) has been developing a suite of phantoms having traceable activity content to enable scanner calibration and performance testing. The configurations range from small solid cylindrical sources having volumes from 1 mL to 23 mL to large cylinders having a total volume of 9 L. The phantoms are constructed with 68Ge as a long-lived substitute for the more clinically useful radionuclide 18F. The contained activity values are traceable to the national standard for 68Ge and are also linked to the standard for 18F through a careful series of comparisons. The techniques that have been developed are being applied to a variety of new phantom configurations using different radionuclides. Image-based additive manufacturing techniques are also being investigated to create fillable phantoms having irregular shapes which can better mimic actual organs and tumors while still maintaining traceability back to primary standards for radioactivity. This talk will describe the methods used to construct, calibrate, and characterize the phantoms, focusing on the preservation of the traceability link to the primary standards of the radionuclides used. The on-going development of specialized traceable phantoms for specific organ dosimetry applications and imaging physics studies will also be discussed.

  1. A Coordinated Research Project on the Implementation of Nuclear Techniques to Improve Food Traceability

    NASA Astrophysics Data System (ADS)

    Frew, Russell; Cannavan, Andrew; Zandric, Zora; Maestroni, Britt; Abrahim, Aiman

    2013-04-01

    Traceability systems play a key role in assuring a safe and reliable food supply. Analytical techniques harnessing the spatial patterns in distribution of stable isotope and trace element ratios can be used for the determination of the provenance of food. Such techniques offer the potential to enhance global trade by providing an independent means of verifying "paper" traceability systems and can also help to prove authenticity, to combat fraudulent practices, and to control adulteration, which are important issues for economic, religious or cultural reasons. To address some of the challenges that developing countries face in attempting to implement effective food traceability systems, the IAEA, through its Joint FAO/IAEA Division on Nuclear Techniques in Food and Agriculture, has initiated a 5-year coordinated research project involving institutes in 15 developing and developed countries (Austria, Botswana, Chile, China, France, India, Lebanon, Morocco, Portugal, Singapore, Sweden, Thailand, Uganda, UK, USA). The objective is to help in member state laboratories to establish robust analytical techniques and databases, validated to international standards, to determine the provenance of food. Nuclear techniques such as stable isotope and multi-element analysis, along with complementary methods, will be applied for the verification of food traceability systems and claims related to food origin, production, and authenticity. This integrated and multidisciplinary approach to strengthening capacity in food traceability will contribute to the effective implementation of holistic systems for food safety and control. The project focuses mainly on the development of techniques to confirm product authenticity, with several research partners also considering food safety issues. Research topics encompass determination of the geographical origin of a variety of commodities, including seed oils, rice, wine, olive oil, wheat, orange juice, fish, groundnuts, tea, pork, honey and coffee, the adulteration of milk with soy protein, chemical contamination of food products, and inhomogeneity in isotopic ratios in poultry and eggs as a means to determine production history. Analytical techniques include stable isotope ratio measurements (2H/1H, 13C/12C, 15N/14N, 18O/16O, 34S/32S, 87Sr/86Sr, 208Pb/207Pb/206Pb), elemental analysis, DNA fingerprinting, fatty acid and other biomolecule profiling, chromatography-mass spectrometry and near infra-red spectroscopy.

  2. Exploration Medical System Trade Study Tools Overview

    NASA Technical Reports Server (NTRS)

    Mindock, J.; Myers, J.; Latorella, K.; Cerro, J.; Hanson, A.; Hailey, M.; Middour, C.

    2018-01-01

    ExMC is creating an ecosystem of tools to enable well-informed medical system trade studies. The suite of tools address important system implementation aspects of the space medical capabilities trade space and are being built using knowledge from the medical community regarding the unique aspects of space flight. Two integrating models, a systems engineering model and a medical risk analysis model, tie the tools together to produce an integrated assessment of the medical system and its ability to achieve medical system target requirements. This presentation will provide an overview of the various tools that are a part of the tool ecosystem. Initially, the presentation's focus will address the tools that supply the foundational information to the ecosystem. Specifically, the talk will describe how information that describes how medicine will be practiced is captured and categorized for efficient utilization in the tool suite. For example, the talk will include capturing what conditions will be planned for in-mission treatment, planned medical activities (e.g., periodic physical exam), required medical capabilities (e.g., provide imaging), and options to implement the capabilities (e.g., an ultrasound device). Database storage and configuration management will also be discussed. The presentation will include an overview of how these information tools will be tied to parameters in a Systems Modeling Language (SysML) model, allowing traceability to system behavioral, structural, and requirements content. The discussion will also describe an HRP-led enhanced risk assessment model developed to provide quantitative insight into each capability's contribution to mission success. Key outputs from these various tools, to be shared with the space medical and exploration mission development communities, will be assessments of medical system implementation option satisfaction of requirements and per-capability contributions toward achieving requirements.

  3. Comprehensive protocol of traceability during IVF: the result of a multicentre failure mode and effect analysis.

    PubMed

    Rienzi, L; Bariani, F; Dalla Zorza, M; Albani, E; Benini, F; Chamayou, S; Minasi, M G; Parmegiani, L; Restelli, L; Vizziello, G; Costa, A Nanni

    2017-08-01

    Can traceability of gametes and embryos be ensured during IVF? The use of a simple and comprehensive traceability system that includes the most susceptible phases during the IVF process minimizes the risk of mismatches. Mismatches in IVF are very rare but unfortunately possible with dramatic consequences for both patients and health care professionals. Traceability is thus a fundamental aspect of the treatment. A clear process of patient and cell identification involving witnessing protocols has to be in place in every unit. To identify potential failures in the traceability process and to develop strategies to mitigate the risk of mismatches, previously failure mode and effects analysis (FMEA) has been used effectively. The FMEA approach is however a subjective analysis, strictly related to specific protocols and thus the results are not always widely applicable. To reduce subjectivity and to obtain a widespread comprehensive protocol of traceability, a multicentre centrally coordinated FMEA was performed. Seven representative Italian centres (three public and four private) were selected. The study had a duration of 21 months (from April 2015 to December 2016) and was centrally coordinated by a team of experts: a risk analysis specialist, an expert embryologist and a specialist in human factor. Principal investigators of each centre were first instructed about proactive risk assessment and FMEA methodology. A multidisciplinary team to perform the FMEA analysis was then formed in each centre. After mapping the traceability process, each team identified the possible causes of mistakes in their protocol. A risk priority number (RPN) for each identified potential failure mode was calculated. The results of the FMEA analyses were centrally investigated and consistent corrective measures suggested. The teams performed new FMEA analyses after the recommended implementations. In each centre, this study involved: the laboratory director, the Quality Control & Quality Assurance responsible, Embryologist(s), Gynaecologist(s), Nurse(s) and Administration. The FMEA analyses were performed according to the Joint Commission International. The FMEA teams identified seven main process phases: oocyte collection, sperm collection, gamete processing, insemination, embryo culture, embryo transfer and gamete/embryo cryopreservation. A mean of 19.3 (SD ± 5.8) associated process steps and 41.9 (SD ± 12.4) possible failure modes were recognized per centre. A RPN ≥15 was calculated in a mean of 6.4 steps (range 2-12, SD ± 3.60). A total of 293 failure modes were centrally analysed 45 of which were considered at medium/high risk. After consistent corrective measures implementation and re-evaluation, a significant reduction in the RPNs in all centres (RPN <15 for all steps) was observed. A simple and comprehensive traceability system was designed as the result of the seven FMEA analyses. The validity of FMEA is in general questionable due to the subjectivity of the judgments. The design of this study has however minimized this risk by introducing external experts for the analysis of the FMEA results. Specific situations such as sperm/oocyte donation, import/export and pre-implantation genetic testing were not taken into consideration. Finally, this study is only limited to the analysis of failure modes that may lead to mismatches, other possible procedural mistakes are not accounted for. Every single IVF centre should have a clear and reliable protocol for identification of patients and traceability of cells during manipulation. The results of this study can support IVF groups in better recognizing critical steps in their protocols, understanding identification and witnessing process, and in turn enhancing safety by introducing validated corrective measures. This study was designed by the Italian Society of Embryology Reproduction and Research (SIERR) and funded by the Italian National Transplant Centre (CNT) of the Italian National Institute of Health (ISS). The authors have no conflicts of interest. N/A. © The Author 2017. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com

  4. Review: Authentication and traceability of foods from animal origin by polymerase chain reaction-based capillary electrophoresis.

    PubMed

    Rodríguez-Ramírez, Roberto; González-Córdova, Aarón F; Vallejo-Cordoba, Belinda

    2011-01-31

    This work presents an overview of the applicability of PCR-based capillary electrophoresis (CE) in food authentication and traceability of foods from animal origin. Analytical approaches for authenticating and tracing meat and meat products and fish and seafood products are discussed. Particular emphasis will be given to the usefulness of genotyping in food tracing by using CE-based genetic analyzers. Copyright © 2010 Elsevier B.V. All rights reserved.

  5. Waste collection multi objective model with real time traceability data.

    PubMed

    Faccio, Maurizio; Persona, Alessandro; Zanin, Giorgia

    2011-12-01

    Waste collection is a highly visible municipal service that involves large expenditures and difficult operational problems, plus it is expensive to operate in terms of investment costs (i.e. vehicles fleet), operational costs (i.e. fuel, maintenances) and environmental costs (i.e. emissions, noise and traffic congestions). Modern traceability devices, like volumetric sensors, identification RFID (Radio Frequency Identification) systems, GPRS (General Packet Radio Service) and GPS (Global Positioning System) technology, permit to obtain data in real time, which is fundamental to implement an efficient and innovative waste collection routing model. The basic idea is that knowing the real time data of each vehicle and the real time replenishment level at each bin makes it possible to decide, in function of the waste generation pattern, what bin should be emptied and what should not, optimizing different aspects like the total covered distance, the necessary number of vehicles and the environmental impact. This paper describes a framework about the traceability technology available in the optimization of solid waste collection, and introduces an innovative vehicle routing model integrated with the real time traceability data, starting the application in an Italian city of about 100,000 inhabitants. The model is tested and validated using simulation and an economical feasibility study is reported at the end of the paper. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. The Joint Committee for Traceability in Laboratory Medicine (JCTLM) - its history and operation.

    PubMed

    Jones, Graham R D; Jackson, Craig

    2016-01-30

    The Joint Committee for Traceability in Laboratory Medicine (JCTLM) was formed to bring together the sciences of metrology, laboratory medicine and laboratory quality management. The aim of this collaboration is to support worldwide comparability and equivalence of measurement results in clinical laboratories for the purpose of improving healthcare. The JCTLM has its origins in the activities of international metrology treaty organizations, professional societies and federations devoted to improving measurement quality in physical, chemical and medical sciences. The three founding organizations, the International Committee for Weights and Measures (CIPM), the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) and the International Laboratory Accreditation Cooperation (ILAC) are the leaders of this activity. The main service of the JCTLM is a web-based database with a list of reference materials, reference methods and reference measurement services meeting appropriate international standards. This database allows manufacturers to select references for assay traceability and provides support for suppliers of these services. As of mid 2015 the database lists 295 reference materials for 162 analytes, 170 reference measurement procedures for 79 analytes and 130 reference measurement services for 39 analytes. There remains a need for the development and implementation of metrological traceability in many areas of laboratory medicine and the JCTLM will continue to promote these activities into the future. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Portable Dew Point Mass Spectrometry System for Real-Time Gas and Moisture Analysis

    NASA Technical Reports Server (NTRS)

    Arkin, C.; Gillespie, Stacey; Ratzel, Christopher

    2010-01-01

    A portable instrument incorporates both mass spectrometry and dew point measurement to provide real-time, quantitative gas measurements of helium, nitrogen, oxygen, argon, and carbon dioxide, along with real-time, quantitative moisture analysis. The Portable Dew Point Mass Spectrometry (PDP-MS) system comprises a single quadrupole mass spectrometer and a high vacuum system consisting of a turbopump and a diaphragm-backing pump. A capacitive membrane dew point sensor was placed upstream of the MS, but still within the pressure-flow control pneumatic region. Pressure-flow control was achieved with an upstream precision metering valve, a capacitance diaphragm gauge, and a downstream mass flow controller. User configurable LabVIEW software was developed to provide real-time concentration data for the MS, dew point monitor, and sample delivery system pressure control, pressure and flow monitoring, and recording. The system has been designed to include in situ, NIST-traceable calibration. Certain sample tubing retains sufficient water that even if the sample is dry, the sample tube will desorb water to an amount resulting in moisture concentration errors up to 500 ppm for as long as 10 minutes. It was determined that Bev-A-Line IV was the best sample line to use. As a result of this issue, it is prudent to add a high-level humidity sensor to PDP-MS so such events can be prevented in the future.

  8. On the Conditioning of Machine-Learning-Assisted Turbulence Modeling

    NASA Astrophysics Data System (ADS)

    Wu, Jinlong; Sun, Rui; Wang, Qiqi; Xiao, Heng

    2017-11-01

    Recently, several researchers have demonstrated that machine learning techniques can be used to improve the RANS modeled Reynolds stress by training on available database of high fidelity simulations. However, obtaining improved mean velocity field remains an unsolved challenge, restricting the predictive capability of current machine-learning-assisted turbulence modeling approaches. In this work we define a condition number to evaluate the model conditioning of data-driven turbulence modeling approaches, and propose a stability-oriented machine learning framework to model Reynolds stress. Two canonical flows, the flow in a square duct and the flow over periodic hills, are investigated to demonstrate the predictive capability of the proposed framework. The satisfactory prediction performance of mean velocity field for both flows demonstrates the predictive capability of the proposed framework for machine-learning-assisted turbulence modeling. With showing the capability of improving the prediction of mean flow field, the proposed stability-oriented machine learning framework bridges the gap between the existing machine-learning-assisted turbulence modeling approaches and the demand of predictive capability of turbulence models in real applications.

  9. Analysis of Substrates of Protein Kinase C Isoforms in Human Breast Cells By The Traceable Kinase Method

    PubMed Central

    Chen, Xiangyu; Zhao, Xin; Abeyweera, Thushara P.; Rotenberg, Susan A.

    2012-01-01

    A previous report (Biochemistry 46: 2364–2370, 2007) described the application of The Traceable Kinase Method to identify substrates of PKCα in non-transformed human breast MCF-10A cells. Here, a non-radioactive variation of this method compared the phospho-protein profiles of three traceable PKC isoforms (α, δ and ζ) for the purpose of identifying novel, isoform-selective substrates. Each FLAG-tagged traceable kinase was expressed and co-immunoprecipitated along with high affinity substrates. The isolated kinase and its associated substrates were subjected to an in vitro phosphorylation reaction with traceable kinase-specific N6-phenyl-ATP, and the resulting phospho-proteins were analyzed by Western blot with an antibody that recognizes the phosphorylated PKC consensus site. Phospho-protein profiles generated by PKC-α and -δ were similar and differed markedly from that of PKC-ζ. Mass spectrometry of selected bands revealed known PKC substrates and several potential substrates that included the small GTPase-associated effector protein Cdc42 effector protein-4 (CEP4). Of those potential substrates tested, only CEP4 was phosphorylated by pure PKC-α, –δ, and −ζ isoforms in vitro, and by endogenous PKC isoforms in MCF-10A cells treated with DAG-lactone, a membrane permeable PKC activator. Under these conditions, the stoichiometry of CEP4 phosphorylation was 3.2 ± 0.5 (mol phospho-CEP4/mol CEP4). Following knock-down with isoform-specific shRNA-encoding plasmids, phosphorylation of CEP4 was substantially decreased in response to silencing of each of the three isoforms (PKC–α, –δ, or –ζ), whereas testing of kinase-dead mutants supported a role for only PKC-α and –δ in CEP4 phosphorylation. These findings identify CEP4 as a novel intracellular PKC substrate that is phosphorylated by multiple PKC isoforms. PMID:22897107

  10. An agile acquisition decision-support workbench for evaluating ISR effectiveness

    NASA Astrophysics Data System (ADS)

    Stouch, Daniel W.; Champagne, Valerie; Mow, Christopher; Rosenberg, Brad; Serrin, Joshua

    2011-06-01

    The U.S. Air Force is consistently evolving to support current and future operations through the planning and execution of intelligence, surveillance and reconnaissance (ISR) missions. However, it is a challenge to maintain a precise awareness of current and emerging ISR capabilities to properly prepare for future conflicts. We present a decisionsupport tool for acquisition managers to empirically compare ISR capabilities and approaches to employing them, thereby enabling the DoD to acquire ISR platforms and sensors that provide the greatest return on investment. We have developed an analysis environment to perform modeling and simulation-based experiments to objectively compare alternatives. First, the analyst specifies an operational scenario for an area of operations by providing terrain and threat information; a set of nominated collections; sensor and platform capabilities; and processing, exploitation, and dissemination (PED) capacities. Next, the analyst selects and configures ISR collection strategies to generate collection plans. The analyst then defines customizable measures of effectiveness or performance to compute during the experiment. Finally, the analyst empirically compares the efficacy of each solution and generates concise reports to document their conclusions, providing traceable evidence for acquisition decisions. Our capability demonstrates the utility of using a workbench environment for analysts to design and run experiments. Crafting impartial metrics enables the acquisition manager to focus on evaluating solutions based on specific military needs. Finally, the metric and collection plan visualizations provide an intuitive understanding of the suitability of particular solutions. This facilitates a more agile acquisition strategy that handles rapidly changing technology in response to current military needs.

  11. A primary standard for the calibration of sniffer test leak devices

    NASA Astrophysics Data System (ADS)

    Jousten, Karl; Becker, Ute

    2009-10-01

    Test leaks with a gas flow to atmospheric pressure are often called sniffer test leaks. They are used to calibrate leak detectors for sniffing applications. Sniffer test leaks need calibration against a standard. A primary standard for the calibration of sniffer test leaks with relatively low measurement uncertainties is described. It is assured that the measurement result is traceable to the relevant SI units and that there is a well-known and complete measurement uncertainty budget. The measurement range of the system is from 4 × 10-11 mol s-1 (corresponding to 10-4 Pa l s-1 at 23 °C) to 4 × 10-9 mol s-1 (10-2 Pa l s-1 at 23 °C), which is the most often needed range in industry of around 1 g loss per year of the cooling agent R134a. The temperature where the calibration can be carried out may vary from 18 °C to 30 °C. The flow rate of any test gas not condensing in this temperature range can be measured.

  12. Quality data collection and management technology of aerospace complex product assembly process

    NASA Astrophysics Data System (ADS)

    Weng, Gang; Liu, Jianhua; He, Yongxi; Zhuang, Cunbo

    2017-04-01

    Aiming at solving problems of difficult management and poor traceability for discrete assembly process quality data, a data collection and management method is proposed which take the assembly process and BOM as the core. Data collection method base on workflow technology, data model base on BOM and quality traceability of assembly process is included in the method. Finally, assembly process quality data management system is developed and effective control and management of quality information for complex product assembly process is realized.

  13. Study and Development of Mobile Tracingterminal Based on Gprs for Agriculturalproducts Quality Tracking

    NASA Astrophysics Data System (ADS)

    Liu, Shihong; Meng, Hong; Zheng, Huoguo; Wu, Jiangshou

    Traceability system has become an important means for food safety management. Global food industry and many countries have paid increasing attention to the construction of food traceability system, but rarely referred to tracing terminal. According to the technical requirements of cereal and oil products quality safety tracing process, we design and develop a mobile tracing terminal based on GPRS for agricultural products quality tracking to facilitate quality supervisors and consumers to track and trace the quality of related agricultural products anytime ,anywhere.

  14. Study of mechanism improving target course traceability in G-Vectoring Control

    NASA Astrophysics Data System (ADS)

    Yamakado, Makoto; Abe, Masato; Kano, Yoshio; Umetsu, Daisuke; Yoshioka, Thoru

    2018-05-01

    Production-type G-Vectoring Control vehicles are now being put on the market. Customers and reviewers have praised the handling quality and course traceability of these vehicles. This paper clarifies the mechanism behind this improvement in handling quality using a simple bicycle model and driver model analysis. It focuses on the residual yaw angular acceleration when the steering speed is zero and shows that GVC reduces its value. This result provides evidence for improved handling quality in GVC vehicles.

  15. A range of newly developed mobile generators to dynamically produce SI-traceable reference gas mixtures for reactive compounds at atmospheric concentrations

    NASA Astrophysics Data System (ADS)

    Leuenberger, Daiana; Pascale, Céline; Guillevic, Myriam; Ackermann, Andreas; Niederhauser, Bernhard

    2017-04-01

    Three new mobile facilities have been developed at METAS to dynamically generate SI-traceable reference gas mixtures for a variety of reactive compounds at atmospheric amount of substance fractions and at very low levels of uncertainty (Ux < 3%). We present three new portable "Reactive Gas Standard ReGaS" reference gas generators for the realisation of the following substances: ReGaS1: Ammonia and nitrogen dioxide in the nmol/mol (ppb) range ReGaS2: Volatile organic compounds (VOCs), e.g. limonene, alpha-pinene, MVK, MEK in the nmol/mol (ppb) range ReGaS-3: Fluorinated gases (F-gases, i.e. containing fluorine atoms) in the pmol/mol (ppt) range These three mobile generators have been designed and manufactured at METAS in the framework of the three EMRP projects MetNH3, KEY-VOCs and HIGHGAS. The method is based on permeation and subsequent dynamic dilution: A permeation tube containing the pure substance (e.g. NH3) is stored in the permeation chamber at constant temperature, pressure and matrix gas flow (N2, purified air, synthetic air). Under such conditions the pure substance permeates at constant rate into the matrix gas and can be diluted thereafter to the desired amount fractions in one or two subsequent steps. The permeation rate (mass loss over time) of the permeation tube is precisely calibrated in a fully traceable magnetic suspension balance. The carrier gas is previously purified from the compounds of interest using commercially available purification cartridges. The permeation chambers of ReGaS2 and ReGaS3 have multiple individual cells allowing for the generation of mixtures containing up to 5 different components if required. ReGaS1 allows for the generation of one-component mixtures only. These primary mixtures are then diluted to the required amount of substance fractions using thermal mass flow controllers for full flexibility and adaptability of the generation process over the entire range of possible concentrations. In order to considerably reduce adsorption/desorption processes and thus stabilisation time, all electro-polished stainless steel parts of ReGaS1 and ReGaS2 in contact with the reference gas mixtures are passivated with SilcoNert2000® surface coating. These three state-of-the-art mobile reference gas generators are applicable under both, laboratory and field conditions. Moreover the dynamic generation method can be adapted and applied to a large variety of molecules (e.g. BTEX, CFCs, HCFCs, HFCs and other refrigerants) and is particularly suitable for reactive gas species and/or at concentration ranges which are unstable when stored in pressurised cylinders. Acknowledgement: This work was supported by the European Metrology Research Programme (EMRP). The EMRP is jointly funded by the EMRP participating countries within EURAMET and the European Union

  16. Effective Materials Property Information Management for the 21st Century

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ren, Weiju; Cebon, David; Barabash, Oleg M

    2011-01-01

    This paper discusses key principles for the development of materials property information management software systems. There are growing needs for automated materials information management in various organizations. In part these are fuelled by the demands for higher efficiency in material testing, product design and engineering analysis. But equally important, organizations are being driven by the needs for consistency, quality and traceability of data, as well as control of access to proprietary or sensitive information. Further, the use of increasingly sophisticated nonlinear, anisotropic and multi-scale engineering analyses requires both processing of large volumes of test data for development of constitutive modelsmore » and complex materials data input for Computer-Aided Engineering (CAE) software. And finally, the globalization of economy often generates great needs for sharing a single gold source of materials information between members of global engineering teams in extended supply-chains. Fortunately material property management systems have kept pace with the growing user demands and evolved to versatile data management systems that can be customized to specific user needs. The more sophisticated of these provide facilities for: (i) data management functions such as access, version, and quality controls; (ii) a wide range of data import, export and analysis capabilities; (iii) data pedigree traceability mechanisms; (iv) data searching, reporting and viewing tools; and (v) access to the information via a wide range of interfaces. In this paper the important requirements for advanced material data management systems, future challenges and opportunities such as automated error checking, data quality characterization, identification of gaps in datasets, as well as functionalities and business models to fuel database growth and maintenance are discussed.« less

  17. Error Budget for a Calibration Demonstration System for the Reflected Solar Instrument for the Climate Absolute Radiance and Refractivity Observatory

    NASA Technical Reports Server (NTRS)

    Thome, Kurtis; McCorkel, Joel; McAndrew, Brendan

    2013-01-01

    A goal of the Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission is to observe highaccuracy, long-term climate change trends over decadal time scales. The key to such a goal is to improving the accuracy of SI traceable absolute calibration across infrared and reflected solar wavelengths allowing climate change to be separated from the limit of natural variability. The advances required to reach on-orbit absolute accuracy to allow climate change observations to survive data gaps exist at NIST in the laboratory, but still need demonstration that the advances can move successfully from to NASA and/or instrument vendor capabilities for spaceborne instruments. The current work describes the radiometric calibration error budget for the Solar, Lunar for Absolute Reflectance Imaging Spectroradiometer (SOLARIS) which is the calibration demonstration system (CDS) for the reflected solar portion of CLARREO. The goal of the CDS is to allow the testing and evaluation of calibration approaches, alternate design and/or implementation approaches and components for the CLARREO mission. SOLARIS also provides a test-bed for detector technologies, non-linearity determination and uncertainties, and application of future technology developments and suggested spacecraft instrument design modifications. The resulting SI-traceable error budget for reflectance retrieval using solar irradiance as a reference and methods for laboratory-based, absolute calibration suitable for climatequality data collections is given. Key components in the error budget are geometry differences between the solar and earth views, knowledge of attenuator behavior when viewing the sun, and sensor behavior such as detector linearity and noise behavior. Methods for demonstrating this error budget are also presented.

  18. Ventilation/perfusion ratios measured by multiple inert gas elimination during experimental cardiopulmonary resuscitation.

    PubMed

    Hartmann, E K; Duenges, B; Boehme, S; Szczyrba, M; Liu, T; Klein, K U; Baumgardner, J E; Markstaller, K; David, M

    2014-09-01

    During cardiopulmonary resuscitation (CPR) the ventilation/perfusion distribution (VA /Q) within the lung is difficult to assess. This experimental study examines the capability of multiple inert gas elimination (MIGET) to determine VA /Q under CPR conditions in a pig model. Twenty-one anaesthetised pigs were randomised to three fractions of inspired oxygen (1.0, 0.7 or 0.21). VA/ Q by micropore membrane inlet mass spectrometry-derived MIGET was determined at baseline and during CPR following induction of ventricular fibrillation. Haemodynamics, blood gases, ventilation distribution by electrical impedance tomography and return of spontaneous circulation were assessed. Intergroup differences were analysed by non-parametric testing. MIGET measurements were feasible in all animals with an excellent correlation of measured and predicted arterial oxygen partial pressure (R(2)  = 0.96, n = 21 for baseline; R(2)  = 0.82, n = 21 for CPR). CPR induces a significant shift from normal VA /Q ratios to the high VA /Q range. Electrical impedance tomography indicates a dorsal to ventral shift of the ventilation distribution. Diverging pulmonary shunt fractions induced by the three inspired oxygen levels considerably increased during CPR and were traceable by MIGET, while 100% oxygen most negatively influenced the VA /Q. Return of spontaneous circulation were achieved in 52% of the animals. VA /Q assessment by MIGET is feasible during CPR and provides a novel tool for experimental purposes. Changes in VA /Q caused by different oxygen fractions are traceable during CPR. Beyond pulmonary perfusion deficits, these data imply an influence of the inspired oxygen level on VA /Q. Higher oxygen levels significantly increase shunt fractions and impair the normal VA /Q ratio. © 2014 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  19. International comparison CCQM-K119 liquefied petroleum gas

    NASA Astrophysics Data System (ADS)

    Brewer, P. J.; Downey, M. L.; Atkins, E.; Brown, R. J. C.; Brown, A. S.; Zalewska, E. T.; van der Veen, A. M. H.; Smeulders, D. E.; McCallum, J. B.; Satumba, R. T.; Kim, Y. D.; Kang, N.; Bae, H. K.; Woo, J. C.; Konopelko, L. A.; Popova, T. A.; Meshkov, A. V.; Efremova, O. V.; Kustikov, Y.

    2018-01-01

    Liquefied hydrocarbon mixtures with traceable composition are required in order to underpin measurements of the composition and other physical properties of LPG (liquefied petroleum gas), thus meeting the needs of an increasingly large industrial market. This comparison aims to assess the analytical capabilities of laboratories for measuring the composition of a Liquid Petroleum Gas (LPG) mixture when sampled in the liquid phase from a Constant Pressure Cylinder. Mixtures contained ethane, propane, propene, i-butane, n-butane, but-1-ene and i-pentane with nominal amount fractions of 2, 71, 9, 4, 10, 3 and 1 cmol mol-1 respectively. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. FIER: Software for analytical modeling of delayed gamma-ray spectra

    NASA Astrophysics Data System (ADS)

    Matthews, E. F.; Goldblum, B. L.; Bernstein, L. A.; Quiter, B. J.; Brown, J. A.; Younes, W.; Burke, J. T.; Padgett, S. W.; Ressler, J. J.; Tonchev, A. P.

    2018-05-01

    A new software package, the Fission Induced Electromagnetic Response (FIER) code, has been developed to analytically predict delayed γ-ray spectra following fission. FIER uses evaluated nuclear data and solutions to the Bateman equations to calculate the time-dependent populations of fission products and their decay daughters resulting from irradiation of a fissionable isotope. These populations are then used in the calculation of γ-ray emission rates to obtain the corresponding delayed γ-ray spectra. FIER output was compared to experimental data obtained by irradiation of a 235U sample in the Godiva critical assembly. This investigation illuminated discrepancies in the input nuclear data libraries, showcasing the usefulness of FIER as a tool to address nuclear data deficiencies through comparison with experimental data. FIER provides traceability between γ-ray emissions and their contributing nuclear species, decay chains, and parent fission fragments, yielding a new capability for the nuclear science community.

  1. Traceability in Patient Healthcare through the Integration of RFID Technology in an ICU in a Hospital.

    PubMed

    Martínez Pérez, María; Dafonte, Carlos; Gómez, Ángel

    2018-05-19

    Patient safety is a principal concern for health professionals in the care process and it is, therefore, necessary to provide information management systems to each unit of the hospital, capable of tracking patients and medication to reduce the occurrence of adverse events and therefore increase the quality of care received by patients during their stay in hospital. This work presents a tool for the Intensive Care Unit (ICU), a key service with special characteristics, which computerises and tracks admissions, care plans, vital monitoring, the prescription and medication administration process for patients in this service. To achieve this, it is essential that innovative and cutting-edge technologies are implemented such as Near Field Communication (NFC) technology which is now being implemented in diverse environments bringing a range of benefits to the tasks for which it is employed.

  2. Long Term Uncertainty Investigations of 1 MN Force Calibration Machine at NPL, India (NPLI)

    NASA Astrophysics Data System (ADS)

    Kumar, Rajesh; Kumar, Harish; Kumar, Anil; Vikram

    2012-01-01

    The present paper is an attempt to study the long term uncertainty of 1 MN hydraulic multiplication system (HMS) force calibration machine (FCM) at the National Physical Laboratory, India (NPLI), which is used for calibration of the force measuring instruments in the range of 100 kN - 1 MN. The 1 MN HMS FCM was installed at NPLI in 1993 and was built on the principle of hydraulic amplifications of dead weights. The best measurement capability (BMC) of the machine is ± 0.025% (k = 2) and it is traceable to national standards by means of precision force transfer standards (FTS). The present study discusses the uncertainty variations of the 1 MN HMS FCM over the years and describes the other parameters in detail, too. The 1 MN HMS FCM was calibrated in the years 2004, 2006, 2007, 2008, 2009 and 2010 and the results have been reported.

  3. JWST Lightweight Mirror TRL-6 Results

    NASA Technical Reports Server (NTRS)

    Stahl, H. Philip

    2007-01-01

    Mirror technology for a Primary Mirror Segment Assembly (PMSA) is a system of components: reflective coating; polished optical surface; mirror substrate; actuators, mechanisms and flexures; and reaction structure. The functional purpose of a PMSA is to survive launch, deploy and align itself to form a 25 square meter collecting area 6.5 meter diameter primary mirror with a 131 nm rms wavefront error at temperatures less than 50K and provide stable optical performance for the anticipated thermal environment. At the inception of JWST in 1996, such a capability was at a Technology Readiness Level (TRL) of 3. A highly successful technology development program was initiated including the Sub-scale Beryllium Mirror Demonstrator (SBMD) and Advanced Mirror System Demonstrator (AMSD) projects. These projects along with flight program activities have matured mirror technology for JWST to TRL-6. A directly traceable prototype (and in some cases the flight hardware itself) has been built, tested and operated in a relevant environment.

  4. Detector Based Realisation of Illuminance Scale at NML-SIRIM

    NASA Astrophysics Data System (ADS)

    Abdullah, Mohd Nizam; Abidin, Mohd Nasir Zainal; Abidin, Abdul Rashid Zainal; Shaari, Sahbudin

    2009-07-01

    Illuminance scale is one of the fundamentals in the realisation of candela in optical radiation. The en route of the realisation is based on the fundamental process from the unbroken chain of traceability which includes from the primary standard disseminated to working standard and lastly the end user. There are many variations towards this realisation even though some of the national metrology institutes (NMI) does not have the primary standard but their traceability still valid. The realisation of National Metrology Laboratory SIRIM (NML-SIRIM), Malaysia illuminance scale is based on detector. The scale is traceable to National Physical Labortaory (NPL), United Kingdom (UK) by annually calibrating photometers and luminous intensity lamp. This paper describes measurement method and the system set-up was previously crosschecked with Korea Research Institute Standards and Science (KRISS), Republic of Korea. The agreement between both laboratories is within 0.5% the uncertainty maintained at NML-SIRIM. Furthermore, the basic measurement equation for illuminance realisation is also derived.

  5. Procedures for establishing and maintaining consistent air-kerma strength standards for low-energy, photon-emitting brachytherapy sources: recommendations of the Calibration Laboratory Accreditation Subcommittee of the American Association of Physicists in Medicine.

    PubMed

    DeWerd, Larry A; Huq, M Saiful; Das, Indra J; Ibbott, Geoffrey S; Hanson, William F; Slowey, Thomas W; Williamson, Jeffrey F; Coursey, Bert M

    2004-03-01

    Low dose rate brachytherapy is being used extensively for the treatment of prostate cancer. As of September 2003, there are a total of thirteen 125I and seven 103Pd sources that have calibrations from the National Institute of Standards and Technology (NIST) and the Accredited Dosimetry Calibration Laboratories (ADCLs) of the American Association of Physicists in Medicine (AAPM). The dosimetry standards for these sources are traceable to the NIST wide-angle free-air chamber. Procedures have been developed by the AAPM Calibration Laboratory Accreditation Subcommittee to standardize quality assurance and calibration, and to maintain the dosimetric traceability of these sources to ensure accurate clinical dosimetry. A description of these procedures is provided to the clinical users for traceability purposes as well as to provide guidance to the manufacturers of brachytherapy sources and ADCLs with regard to these procedures.

  6. Traceability and Quality Control in Traditional Chinese Medicine: From Chemical Fingerprint to Two-Dimensional Barcode.

    PubMed

    Cai, Yong; Li, Xiwen; Li, Mei; Chen, Xiaojia; Hu, Hao; Ni, Jingyun; Wang, Yitao

    2015-01-01

    Chemical fingerprinting is currently a widely used tool that enables rapid and accurate quality evaluation of Traditional Chinese Medicine (TCM). However, chemical fingerprints are not amenable to information storage, recognition, and retrieval, which limit their use in Chinese medicine traceability. In this study, samples of three kinds of Chinese medicines were randomly selected and chemical fingerprints were then constructed by using high performance liquid chromatography. Based on chemical data, the process of converting the TCM chemical fingerprint into two-dimensional code is presented; preprocess and filtering algorithm are also proposed aiming at standardizing the large amount of original raw data. In order to know which type of two-dimensional code (2D) is suitable for storing data of chemical fingerprints, current popular types of 2D codes are analyzed and compared. Results show that QR Code is suitable for recording the TCM chemical fingerprint. The fingerprint information of TCM can be converted into data format that can be stored as 2D code for traceability and quality control.

  7. Combination of watermarking and joint watermarking-decryption for reliability control and traceability of medical images.

    PubMed

    Bouslimi, D; Coatrieux, G; Cozic, M; Roux, Ch

    2014-01-01

    In this paper, we propose a novel crypto-watermarking system for the purpose of verifying the reliability of images and tracing them, i.e. identifying the person at the origin of an illegal distribution. This system couples a common watermarking method, based on Quantization Index Modulation (QIM), and a joint watermarking-decryption (JWD) approach. At the emitter side, it allows the insertion of a watermark as a proof of reliability of the image before sending it encrypted; at the reception, another watermark, a proof of traceability, is embedded during the decryption process. The scheme we propose makes interoperate such a combination of watermarking approaches taking into account risks of interferences between embedded watermarks, allowing the access to both reliability and traceability proofs. Experimental results confirm the efficiency of our system, and demonstrate it can be used to identify the physician at the origin of a disclosure even if the image has been modified.

  8. Traceability of 'Limone di Siracusa PGI' by a multidisciplinary analytical and chemometric approach.

    PubMed

    Amenta, M; Fabroni, S; Costa, C; Rapisarda, P

    2016-11-15

    Food traceability is increasingly relevant with respect to safety, quality and typicality issues. Lemon fruits grown in a typical lemon-growing area of southern Italy (Siracusa), have been awarded the PGI (Protected Geographical Indication) recognition as 'Limone di Siracusa'. Due to its peculiarity, consumers have an increasing interest about this product. The detection of potential fraud could be improved by using the tools linking the composition of this production to its typical features. This study used a wide range of analytical techniques, including conventional techniques and analytical approaches, such as spectral (NIR spectra), multi-elemental (Fe, Zn, Mn, Cu, Li, Sr) and isotopic ((13)C/(12)C, (18)O/(16)O) marker investigations, joined with multivariate statistical analysis, such as PLS-DA (Partial Least Squares Discriminant Analysis) and LDA (Linear Discriminant Analysis), to implement a traceability system to verify the authenticity of 'Limone di Siracusa' production. The results demonstrated a very good geographical discrimination rate. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Genetic characterization of Italian tomato varieties and their traceability in tomato food products-Sardaro-2012-Food Science & Nutrition-Wiley Online Library

    PubMed Central

    Sardaro, Maria Luisa Savo; Marmiroli, Marta; Maestri, Elena; Marmiroli, Nelson

    2013-01-01

    Genetic diversity underlies the improvement of crops by plant breeding. Landraces of tomato (Solanum lycopersicum L.) can contain valuable alleles not common in modern germplasms. The aim was to measure genetic diversity present in 47 most common tomato varieties grown in Italy, 35 were varieties used for processing and 12 were landraces considered “salad varieties”. Furthermore, we demonstrated the possibility that the variety traceability can be extended through the entire production chain. Diversity was measured using 11 microsatellite markers and 94 genotypes. Among the markers used, a total of 48 alleles were detected. A dendrogram based on total microsatellite polymorphism grouped 47 varieties into three major clusters at 0.75 similarity coefficient, differentiating the modern varieties from tomatoes landraces. The DNA markers developed confirmed the possibility to support the genotype identification all along the tomato production chain. The number of alleles and genotypes identified in the present work is the largest considering papers on food traceability. PMID:24804014

  10. Genetic characterization of Italian tomato varieties and their traceability in tomato food products-Sardaro-2012-Food Science & Nutrition-Wiley Online Library.

    PubMed

    Sardaro, Maria Luisa Savo; Marmiroli, Marta; Maestri, Elena; Marmiroli, Nelson

    2013-01-01

    Genetic diversity underlies the improvement of crops by plant breeding. Landraces of tomato (Solanum lycopersicum L.) can contain valuable alleles not common in modern germplasms. The aim was to measure genetic diversity present in 47 most common tomato varieties grown in Italy, 35 were varieties used for processing and 12 were landraces considered "salad varieties". Furthermore, we demonstrated the possibility that the variety traceability can be extended through the entire production chain. Diversity was measured using 11 microsatellite markers and 94 genotypes. Among the markers used, a total of 48 alleles were detected. A dendrogram based on total microsatellite polymorphism grouped 47 varieties into three major clusters at 0.75 similarity coefficient, differentiating the modern varieties from tomatoes landraces. The DNA markers developed confirmed the possibility to support the genotype identification all along the tomato production chain. The number of alleles and genotypes identified in the present work is the largest considering papers on food traceability.

  11. Assessment of Recovery of Milk Protein Allergens from Processed Food for Mass Spectrometry Quantification.

    PubMed

    Groves, Kate; Cryar, Adam; Walker, Michael; Quaglia, Milena

    2018-01-01

    Assessing the recovery of food allergens from solid processed matrixes is one of the most difficult steps that needs to be overcome to enable the accurate quantification of protein allergens by immunoassay and MS. A feasibility study is described herein applying International System of Units (SI)-traceably quantified milk protein solutions to assess recovery by an improved extraction method. Untargeted MS analysis suggests that this novel extraction method can be further developed to provide high recoveries for a broad range of food allergens. A solution of α-casein was traceably quantified to the SI for the content of α-S1 casein. Cookie dough was prepared by spiking a known amount of the SI-traceable quantified solution into a mixture of flour, sugar, and soya spread, followed by baking. A novel method for the extraction of protein food allergens from solid matrixes based on proteolytic digestion was developed, and its performance was compared with the performance of methods reported in the literature.

  12. Authenticity and traceability of vanilla flavors by analysis of stable isotopes of carbon and hydrogen.

    PubMed

    Hansen, Anne-Mette Sølvbjerg; Fromberg, Arvid; Frandsen, Henrik Lauritz

    2014-10-22

    Authenticity and traceability of vanilla flavors were investigated using gas chromatography-isotope ratio mass spectrometry (GC-IRMS). Vanilla flavors produced by chemical synthesis (n = 2), fermentation (n = 1), and extracted from two different species of the vanilla orchid (n = 79) were analyzed. The authenticity of the flavor compound vanillin was evaluated on the basis of measurements of ratios of carbon stable isotopes (δ(13)C). It was found that results of δ(13)C for vanillin extracted from Vanilla planifolia and Vanilla tahitensis were significantly different (t test) and that it was possible to differentiate these two groups of natural vanillin from vanillin produced otherwise. Vanilla flavors were also analyzed for ratios of hydrogen stable isotopes (δ(2)H). A graphic representation of δ(13)C versus δ(2)H revealed that vanillin extracted from pods grown in adjacent geographic origins grouped together. Accordingly, values of δ(13)C and δ(2)H can be used for studies of authenticity and traceability of vanilla flavors.

  13. Nuclear reference materials to meet the changing needs of the global nuclear community

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, H.R.; Gradle, C.G.; Narayanan, U.I.

    New Brunswick Laboratory (NBL) serves as the U.S. Government`s certifying authority for nuclear reference materials and measurement calibration standards. In this role, NBL provides nuclear reference materials certified for chemical and/or isotopic compositions traceable to a nationally accepted, internationally compatible reference base. Emphasis is now changing as to the types of traceable nuclear reference materials needed as operations change within the Department of Energy complex and at nuclear facilities around the world. New challenges include: environmental and waste minimization issues, facilities and materials transitioning from processing to storage modes with corresponding changes in the types of measurements being performed, emphasismore » on requirements for characterization of waste materials, and difficulties in transporting nuclear materials and international factors, including IAEA influences. During these changing times, it is critical that traceable reference materials be provided for calibration or validation of the performance of measurement systems. This paper will describe actions taken and planned to meet the changing reference material needs of the global nuclear community.« less

  14. From soil to grape and wine: Variation of light and heavy elements isotope ratios.

    PubMed

    Durante, Caterina; Bertacchini, Lucia; Bontempo, Luana; Camin, Federica; Manzini, Daniela; Lambertini, Paolo; Marchetti, Andrea; Paolini, Mauro

    2016-11-01

    In the development of a geographical traceability model, it is necessary to understand if the value of the monitored indicators in a food is correlated to its origin or if it is also influenced by 'external factors' such as those coming from its production. In this study, a deeper investigation of the trend of direct geographical traceability indicators along the winemaking process of two traditional oenological products was carried out. Different processes were monitored, sampling each step of their production (grape juice, intermediate products and wine). The results related to the determinations of δ(18)O, (D/H)I, (D/H)II, δ(13)C, δ(15)N and (87)Sr/(86)Sr have been reported. Furthermore, correspondence with the isotopic values coming from the respective soil and vine-branch samples have been investigated as well, showing the optimal traceability power of the monitored geographical tracers. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. NGS tools for traceability in candies as high processed food products: Ion Torrent PGM versus conventional PCR-cloning.

    PubMed

    Muñoz-Colmenero, Marta; Martínez, Jose Luis; Roca, Agustín; Garcia-Vazquez, Eva

    2017-01-01

    The Next Generation Sequencing methodologies are considered the next step within DNA-based methods and their applicability in different fields is being evaluated. Here, we tested the usefulness of the Ion Torrent Personal Genome Machine (PGM) in food traceability analyzing candies as a model of high processed foods, and compared the results with those obtained by PCR-cloning-sequencing (PCR-CS). The majority of samples exhibited consistency between methodologies, yielding more information and species per product from the PGM platform than PCR-CS. Significantly higher AT-content in sequences of the same species was also obtained from PGM. This together with some taxonomical discrepancies between methodologies suggest that the PGM platform is still pre-mature for its use in food traceability of complex highly processed products. It could be a good option for analysis of less complex food, saving time and cost per sample. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Method for traceable measurement of LTE signals

    NASA Astrophysics Data System (ADS)

    Sunder Dash, Soumya; Pythoud, Frederic; Leuchtmann, Pascal; Leuthold, Juerg

    2018-04-01

    This contribution presents a reference setup to measure the power of the cell-specific resource elements present in downlink long term evolution (LTE) signals in a way that the measurements are traceable to the international system of units. This setup can be used to calibrate the LTE code-selective field probes that are used to measure the radiation of base stations for mobile telephony. It can also be used to calibrate LTE signal generators and receivers. The method is based on traceable scope measurements performed directly at the output of a measuring antenna. It implements offline digital signal processing demodulation algorithms that consider the digital down-conversion, timing synchronization, frequency synchronization, phase synchronization and robust LTE cell identification to produce the downlink time-frequency LTE grid. Experimental results on conducted test scenarios, both single-input-single-output and multiple-input-multiple-output antenna configuration, show promising results confirming measurement uncertainties of the order of 0.05 dB with a coverage factor of 2.

  17. Absolute sulfur isotope amount ratios in two batches of high purity SO2 gas: sulfur isotope reference materials IRMM-2012 and IRMM-2013

    NASA Astrophysics Data System (ADS)

    Valkiers, S.; Ding, T.; Ruße, K.; de Bièvre, P.; Taylor, P. D. P.

    2005-04-01

    SI-traceable ("absolute") values have been obtained for sulfur isotope amount ratios n(33S)/n(32S) and n(34S)/n(32S), in two batches of high purity SO2 gas (IRMM-2012 and IRMM-2013). The SO2 gas was converted at IMR-Beijing to Ag2S, then fluorinated to SF6 gas both at IMR-Beijing and at IRMM-Geel. Yields of different conversion methods exceeded 99%. The sulfur amount-of-substance measurements were performed by gas mass spectrometry on SF5+ ions using "IRMM's amount comparator II". These isotope amount ratios were calibrated by means of gravimetrically prepared synthetic mixtures of highly enriched sulfur isotopes (32S, 33S and 34S) in Ag2S form. The ratio values in the SO2 Secondary Measurement Standard are traceable to the SI system. They can be used in the calibration of field sulfur isotope measurements thus making these metrologically traceable to the SI.

  18. Acoustic emission transducers--development of a facility for traceable out-of-plane displacement calibration.

    PubMed

    Theobald, P D; Esward, T J; Dowson, S P; Preston, R C

    2005-03-01

    Acoustic emission (AE) is a widely used technique that has been employed for the integrity testing of a range of vessels and structures for many years. The last decade has seen advances in signal processing, such that the reliability of AE technology is now being recognised by a wider range of industries. Furthermore, the need for quality control at the manufacturing stage, and requirements of in-service testing, is encouraging the issue of traceable measurements to be addressed. Currently, no independent calibration service for acoustic emission transducers is available within Europe. The UKs National Physical Laboratory (NPL) is undertaking work to develop a measurement facility for the traceable calibration of AE sensors. Such calibrations can contribute to greater acceptance of AE techniques in general, by meeting quality system and other traceability requirements. In this paper the key issues surrounding the development of such a facility are reviewed, including the need to establish repeatable AE sources, select suitable test blocks and to understand the limitations imposed by AE sensors themselves. To provide an absolute measurement of the displacement on the surface of a test block, laser interferometry is employed. In this way the output voltage of an AE sensor can be directly related to the displacement detected at the block surface. A possible calibration methodology is discussed and preliminary calibration results are presented for a commercially available AE sensor, showing its response to longitudinal wave modes.

  19. Harmonisation of seven common enzyme results through EQA.

    PubMed

    Weykamp, Cas; Franck, Paul; Gunnewiek, Jacqueline Klein; de Jonge, Robert; Kuypers, Aldy; van Loon, Douwe; Steigstra, Herman; Cobbaert, Christa

    2014-11-01

    Equivalent results between different laboratories enable optimal patient care and can be achieved with harmonisation. We report on EQA-initiated national harmonisation of seven enzymes using commutable samples. EQA samples were prepared from human serum spiked with human recombinant enzymes. Target values were assigned with the IFCC Reference Measurement Procedures. The same samples were included at four occasions in the EQA programmes of 2012 and 2013. Laboratories were encouraged to report IFCC traceable results. A parallel study was done to confirm commutability of the samples. Of the 223 participating laboratories, 95% reported IFCC traceable results, ranging from 98% (ASAT) to 87% (amylase). Users of Roche and Siemens (97%) more frequently reported in IFCC traceable results than users of Abbott (91%), Beckman (90%), and Olympus (87%). The success of harmonisation, expressed as the recovery of assigned values and the inter-laboratory CV was: ALAT (recovery 100%; inter-lab CV 4%), ASAT (102%; 4%), LD (98%; 3%), CK (101%; 5%), GGT (98%; 4%), AP (96%; 6%), amylase (99%; 4%). There were no significant differences between the manufacturers. Commutability was demonstrated in the parallel study. Equal results in the same sample in the 2012 and 2013 EQA programmes demonstrated stability of the samples. The EQA-initiated national harmonisation of seven enzymes, using stable, commutable human serum samples, spiked with human recombinant enzymes, and targeted with the IFCC Reference Measurement Procedures, was successful in terms of implementation of IFCC traceable results (95%), recovery of the target (99%), and inter-laboratory CV (4%).

  20. [Report of the NEDO project "Research and development to promote the creation and utilization of an intellectual infrastructure: development of reference materials for laboratory medicine" "Development of pure substance-type certified reference materials"].

    PubMed

    Takatsu, Akiko

    2009-06-01

    There is an increasing demand to establish a metrological traceability system for in vitro diagnostics and medical devices. Pure substance-type reference materials are playing key roles in metrological traceability, because they form the basis for many traceability chains in chemistry. The National Metrology Institute of Japan (NMIJ), in the National Institute of Advanced Industrial Science and Technology (AIST), has been developing purity-certified reference materials (CRMs) in this field, such as cholesterol, creatinine, and urea. In the New Energy and Industrial Technology Development Organization (NEDO) project, entitled: "Research and Development to Promote the Creation and Utilization of an Intellectual Infrastructure: Development of Reference Materials for Laboratory Medicine", several pure substance-type CRMs were developed. For a pure protein solution CRM, amino acid analysis and nitrogen determination were chosen as the certification methods. The development and certification processes for the C-reactive protein (CRP) solution CRM were completed, with the recombinant human CRP solution as a candidate material. This CRP solution CRM is now available as NMIJ CRM. For cortisol CRM, a purified candidate material and highly pure primary reference material were prepared. Each impure compound in the materials was identified and quantified. The pure cortisol CRM will be available in 2009. These two CRMs provide a traceability link between routine clinical methods and the SI unit.

  1. Establishing traceability of photometric absorbance values for accurate measurements of the haemoglobin concentration in blood

    NASA Astrophysics Data System (ADS)

    Witt, K.; Wolf, H. U.; Heuck, C.; Kammel, M.; Kummrow, A.; Neukammer, J.

    2013-10-01

    Haemoglobin concentration in blood is one of the most frequently measured analytes in laboratory medicine. Reference and routine methods for the determination of the haemoglobin concentration in blood are based on the conversion of haeme, haemoglobin and haemiglobin species into uniform end products. The total haemoglobin concentration in blood is measured using the absorbance of the reaction products. Traceable absorbance measurement values on the highest metrological level are a prerequisite for the calibration and evaluation of procedures with respect to their suitability for routine measurements and their potential as reference measurement procedures. For this purpose, we describe a procedure to establish traceability of spectral absorbance measurements for the haemiglobincyanide (HiCN) method and for the alkaline haematin detergent (AHD) method. The latter is characterized by a higher stability of the reaction product. In addition, the toxic hazard of cyanide, which binds to the iron ion of the haem group and thus inhibits the oxygen transport, is avoided. Traceability is established at different wavelengths by applying total least-squares analysis to derive the conventional quantity values for the absorbance from the measured values. Extrapolation and interpolation are applied to get access to the spectral regions required to characterize the Q-absorption bands of the HiCN and AHD methods, respectively. For absorbance values between 0.3 and 1.8, the contributions of absorbance measurements to the total expanded uncertainties (95% level of confidence) of absorbance measurements range from 1% to 0.4%.

  2. GPS Disciplined Oscillators for Traceability to the Italian Time Standard

    NASA Technical Reports Server (NTRS)

    Cordara, Franco; Pettiti, Valerio

    1996-01-01

    The Istituo Elettrotecnico Nazionale (IEN) is one of the Italian primary institutes which is responsible for the accreditation of secondary laboratories belong to the national calibration system (SNT) established by law in 1991. The Times and Frequency Department that has accredited in this frame 14 calibration centers for frequency, performs also the remote calibration of their reference oscillators by means of different synchronization systems. The problem of establishing the traceability of the national time standard of the Global Positioning System (GPS) disciplined oscillators has been investigated and the results obtained are reported.

  3. An RFID-Based Manufacturing Control Framework for Loosely Coupled Distributed Manufacturing System Supporting Mass Customization

    NASA Astrophysics Data System (ADS)

    Chen, Ruey-Shun; Tsai, Yung-Shun; Tu, Arthur

    In this study we propose a manufacturing control framework based on radio-frequency identification (RFID) technology and a distributed information system to construct a mass-customization production process in a loosely coupled shop-floor control environment. On the basis of this framework, we developed RFID middleware and an integrated information system for tracking and controlling the manufacturing process flow. A bicycle manufacturer was used to demonstrate the prototype system. The findings of this study were that the proposed framework can improve the visibility and traceability of the manufacturing process as well as enhance process quality control and real-time production pedigree access. Using this framework, an enterprise can easily integrate an RFID-based system into its manufacturing environment to facilitate mass customization and a just-in-time production model.

  4. Final report on CIPM key comparison CCM.FF-K6.2011: Comparison of the primary (national) standards of low-pressure gas flow

    NASA Astrophysics Data System (ADS)

    Benková, Miroslava; Makovnik, Stefan; Mickan, Bodo; Arias, Roberto; Chahine, Khaled; Funaki, Tatsuya; Li, Chunhui; Choi, Hae Man; Seredyuk, Denys; Su, Chun-Min; Windenberg, Christophe; Wright, John

    2014-01-01

    The comparison CCM.FF-K6.2011 was organized for the purpose of determination of the degree of equivalence of the national standards for low-pressure gas flow measurement over the range (2 to 100) m3/h. A rotary gas meter was used as a transfer standard. The measurements were provided at prescribed reference conditions. Eleven laboratories from four RMOs participated in this key comparison—EURAMET: PTB, Germany; SMU, Slovakia; LNE-LADG, France; SIM: NIST, USA; CENAM, Mexico; APMP: NMIJ AIST Japan; KRISS, Korea; NMI, Australia; NIM, China; CMS, Chinese Taipei; COOMET: GP GP Ivano-Frankivs'kstandart-metrologia, Ukraine and all participants reported independent traceability chains to the SI. All results were used in the determination of the key comparison reference value (KCRV) and the uncertainty of the KCRV. The reference value was determined at each flow separately following procedure A presented by M G Cox. The degree of equivalence with the KCRV was also calculated for each flow and laboratory. All reported results were consistent with the KCRV. This KCRV can now be used in the further regional comparisons. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  5. A bio-inspired real-time capable artificial lateral line system for freestream flow measurements.

    PubMed

    Abels, C; Qualtieri, A; De Vittorio, M; Megill, W M; Rizzi, F

    2016-06-03

    To enhance today's artificial flow sensing capabilities in aerial and underwater robotics, future robots could be equipped with a large number of miniaturized sensors distributed over the surface to provide high resolution measurement of the surrounding fluid flow. In this work we show a linear array of closely separated bio-inspired micro-electro-mechanical flow sensors whose sensing mechanism is based on a piezoresistive strain-gauge along a stress-driven cantilever beam, mimicking the biological superficial neuromasts found in the lateral line organ of fishes. Aiming to improve state-of-the-art flow sensing capability in autonomously flying and swimming robots, our artificial lateral line system was designed and developed to feature multi-parameter freestream flow measurements which provide information about (1) local flow velocities as measured by the signal amplitudes from the individual cantilevers as well as (2) propagation velocity, (3) linear forward/backward direction along the cantilever beam orientation and (4) periodicity of pulses or pulse trains determined by cross-correlating sensor signals. A real-time capable cross-correlation procedure was developed which makes it possible to extract freestream flow direction and velocity information from flow fluctuations. The computed flow velocities deviate from a commercial system by 0.09 m s(-1) at 0.5 m s(-1) and 0.15 m s(-1) at 1.0 m s(-1) flow velocity for a sampling rate of 240 Hz and a sensor distance of 38 mm. Although experiments were performed in air, the presented flow sensing system can be applied to underwater vehicles as well, once the sensors are embedded in a waterproof micro-electro-mechanical systems package.

  6. What metrology can do to improve the quality of your atmospheric ammonia measurements

    NASA Astrophysics Data System (ADS)

    Leuenberger, Daiana; Martin, Nicholas A.; Pascale, Céline; Guillevic, Myriam; Ackermann, Andreas; Ferracci, Valerio; Cassidy, Nathan; Hook, Josh; Battersby, Ross M.; Tang, Yuk S.; Stevens, Amy C. M.; Jones, Matthew R.; Braban, Christine F.; Gates, Linda; Hangartner, Markus; Sacco, Paolo; Pagani, Diego; Hoffnagle, John A.; Niederhauser, Bernhard

    2017-04-01

    Measuring ammonia in ambient air is a sensitive and priority issue due to its harmful effects on human health and ecosystems. The European Directive 2001/81/EC on "National Emission Ceilings for Certain Atmospheric Pollutants (NEC)" regulates ammonia emissions in the member states. However, there is a lack of regulation to ensure reliable ammonia measurements, namely in applicable analytical technology, maximum allowed uncertainty, quality assurance and quality control (QC/QA) procedures, as well as in the infrastructure to attain metrological traceability, i.e. that the results of measurements are traceable to SI-units through an unbroken chain of calibrations. In the framework of the European Metrology Research Programme (EMRP) project on the topic "Metrology for Ammonia in Ambient Air" (MetNH3), European national metrology institutes (NMI's) have joined to tackle the issue of generating SI-traceable reference material, i.e. generate reference gas mixtures containing known amount fractions of NH3.This requires special infrastructure and analytical techniques: Measurements of ambient ammonia are commonly carried out with diffusive samplers or by active sampling with denuders, but such techniques have not yet been extensively validated. Improvements in the metrological traceability may be achieved through the determination of NH3 diffusive sampling rates using ammonia Primary Standard Gas Mixtures (PSMs), developed by gravimetry at the National Physical Laboratory NPL and a controlled atmosphere test facility in combination with on-line monitoring with a cavity ring-down spectrometer. The Federal Institute of Metrology METAS has developed an infrastructure to generate SI-traceable NH3 reference gas mixtures dynamically in the amount fraction range 0.5-500 nmol/mol (atmospheric concentrations) and with uncertainties UNH3 <3%. The infrastructure consists of a stationary as well as a mobile device for full flexibility for calibrations in the laboratory and in the field. Both devices apply the method of temperature and pressure dependant permeation of a pure substance through a membrane into a stream of pre-purified matrix gas and subsequent dilution to required amount fractions. All relevant parameters are fully traceable to SI-units. Extractive optical analysers can be connected directly to both, stationary and mobile systems for calibration. Moreover, the resulting gas mixture can also be pressurised into coated cylinders by cryo-filling. The mobile system as well as these cylinders can be applied for calibrations of optical instruments in other laboratories and in the field. In addition, an SI-traceable dilution system based on a cascade of critical orifices has been established to dilute NH3 mixtures in the order of μmol/mol stored in cylinders. It is planned to apply this system to calibrate and re-sample gas mixtures in cylinders due to its very economical gas use. Here we present insights into the development of said infrastructure and results performance tests. Moreover, we include results of the study on adsorption/desorption effects in dry as well as humidified matrix gas into the discussion on the generation of reference gas mixtures. Acknowledgement: This work was supported by the European Metrology Research Programme (EMRP). The EMRP is jointly funded by the EMRP participating countries within EURAMET and the European Union.

  7. Time Dependent Simulation of Turbopump Flows

    NASA Technical Reports Server (NTRS)

    Kiris, Cetin C.; Kwak, Dochan; Chan, William; Williams, Robert

    2001-01-01

    The objective of this viewgraph presentation is to enhance incompressible flow simulation capability for developing aerospace vehicle components, especially unsteady flow phenomena associated with high speed turbo pumps. Unsteady Space Shuttle Main Engine (SSME)-rig1 1 1/2 rotations are completed for the 34.3 million grid points model. The moving boundary capability is obtained by using the DCF module. MLP shared memory parallelism has been implemented and benchmarked in INS3D. The scripting capability from CAD geometry to solution is developed. Data compression is applied to reduce data size in post processing and fluid/structure coupling is initiated.

  8. Planning and tracking chemotherapy production for cancer treatment: a performing and integrated solution.

    PubMed

    Kergosien, Y; Tournamille, J-F; Laurence, B; Billaut, J-C

    2011-09-01

    Chemotherapy drugs are intended for the treatment of cancer. The production of such drugs and their administration to the patient is a delicate and expensive operation. The study deals with the acquisition and processing of data regarding the production of intravenous chemotherapy, from the production request (the medical prescription), the production itself (pharmaceutical process), to the delivery in the health care unit, for the administration of the chemotherapy. The goal of this study is to develop a system that can schedule, control and track the chemotherapy preparations and satisfy a certification process of quality management ("ISO 9001 version 2000" standard). The solution proposed in this paper was developed within the framework of a common certification process at the Biopharmaceutical Unit of the Oncology Clinic (UBCO) of the Bretonneau hospital in Tours (France). The system consists of two software programs: a software to insure traceability and a decision making software to plan the production. To simplify the data entry process, some mobile entry points with bar code reader have been deployed. These tools enable an accurate tracking of the production, a security and control for the schedule production phases, and a full traceability of each operation leading to the administration of the chemotherapy drug. The first result is a software that creates the production schedule, allows a real time control of the production process and a full traceability of each step. Computational experiments are based on real data sets, with a comparison of a time period before and after the implementation of this solution. The results show the positive impacts of this software, like the reduction of delayed deliveries, real time generation of production indicators, optimization of the production and a saving of staff time. This intuitive system guarantees a traceability in connection with a high quality system certified ISO 9001-v2000 (with a rapid data entry), an assistant to schedule the production of preparations in a better way, a permanent follow-up and analysis of operations. This project proves the benefits of implementing computer solutions for the traceability and assistance in decision making in the hospital systems. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  9. Improving the Traceability of Meteorological Measurements at Automatic Weather Stations in Thailand

    NASA Astrophysics Data System (ADS)

    Keawprasert, T.; Sinhaneti, T.; Phuuntharo, P.; Phanakulwijit, S.; Nimsamer, A.

    2017-08-01

    A joint project between the National Institute of Metrology Thailand (NIMT) and the Thai Meteorology Department (TMD) was established for improving the traceability of meteorology measurements at automatic weather stations (AWSs) in Thailand. The project aimed to improve traceability of air temperature, relative humidity and atmospheric pressure by implementing on-site calibration facilities and developing of new calibration procedures. First, new portable calibration facilities for air temperature, humidity and pressure were set up as working standard of the TMD. A portable humidity calibrator was applied as a uniform and stable source for calibration of thermo-hygrometers. A dew-point hygrometer was employed as reference hygrometer and a platinum resistance thermometer (PRT) traceable to NIMT was used as reference thermometer. The uniformity and stability in both temperature and relative humidity were characterized at NIMT. A transportable pressure calibrator was used for calibration of air pressure sensor. The estimate overall uncertainty of the calibration setup is 0.2 K for air temperature, 1.0 % for relative humidity and 0.2 hPa for atmospheric pressure, respectively. Second, on-site calibration procedures were developed and four AWSs in the central part and the northern of Thailand were chosen as pilot stations for on-site calibration using the new calibration setups and developed calibration procedures. At each station, the calibration was done at the minimum temperature, average temperature and maximum temperature of the year, for air temperature, 20 %, 55 % and 90 % for relative humidity at the average air temperature of that station and at a one-year statistics pressure range for atmospheric pressure at ambient temperature. Additional in-field uncertainty contributions such as the temperature dependence on relative humidity measurement were evaluated and included in the overall uncertainty budget. Preliminary calibration results showed that using a separate PRT probe at these AWSs would be recommended for improving the accuracy of air temperature measurement. In case of relative humidity measurement, the data logger software is needed to be upgraded for achieving higher accuracy of less than 3 %. For atmospheric pressure measurement, a higher accuracy barometer traceable to NIMT could be used to reduce the calibration uncertainty to below 0.2 hPa.

  10. Providing traceability for neuroimaging analyses.

    PubMed

    McClatchey, Richard; Branson, Andrew; Anjum, Ashiq; Bloodsworth, Peter; Habib, Irfan; Munir, Kamran; Shamdasani, Jetendr; Soomro, Kamran

    2013-09-01

    With the increasingly digital nature of biomedical data and as the complexity of analyses in medical research increases, the need for accurate information capture, traceability and accessibility has become crucial to medical researchers in the pursuance of their research goals. Grid- or Cloud-based technologies, often based on so-called Service Oriented Architectures (SOA), are increasingly being seen as viable solutions for managing distributed data and algorithms in the bio-medical domain. For neuroscientific analyses, especially those centred on complex image analysis, traceability of processes and datasets is essential but up to now this has not been captured in a manner that facilitates collaborative study. Few examples exist, of deployed medical systems based on Grids that provide the traceability of research data needed to facilitate complex analyses and none have been evaluated in practice. Over the past decade, we have been working with mammographers, paediatricians and neuroscientists in three generations of projects to provide the data management and provenance services now required for 21st century medical research. This paper outlines the finding of a requirements study and a resulting system architecture for the production of services to support neuroscientific studies of biomarkers for Alzheimer's disease. The paper proposes a software infrastructure and services that provide the foundation for such support. It introduces the use of the CRISTAL software to provide provenance management as one of a number of services delivered on a SOA, deployed to manage neuroimaging projects that have been studying biomarkers for Alzheimer's disease. In the neuGRID and N4U projects a Provenance Service has been delivered that captures and reconstructs the workflow information needed to facilitate researchers in conducting neuroimaging analyses. The software enables neuroscientists to track the evolution of workflows and datasets. It also tracks the outcomes of various analyses and provides provenance traceability throughout the lifecycle of their studies. As the Provenance Service has been designed to be generic it can be applied across the medical domain as a reusable tool for supporting medical researchers thus providing communities of researchers for the first time with the necessary tools to conduct widely distributed collaborative programmes of medical analysis. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  11. Quality transitivity and traceability system of herbal medicine products based on quality markers.

    PubMed

    Liu, Changxiao; Guo, De-An; Liu, Liang

    2018-05-15

    Due to a variety of factors to affect the herb quality, the existing quality management model is unable to evaluate the process control. The development of the concept of "quality marker" (Q-marker) lays basis for establishing an independent process quality control system for herbal products. To ensure the highest degree of safety, effectiveness and quality process control of herbal products, it is aimed to establish a quality transitivity and traceability system of quality and process control from raw materials to finished herbal products. Based on the key issues and challenges of quality assessment, the current status of quality and process controls from raw materials to herbal medicinal products listed in Pharmacopoeia were analyzed and the research models including discovery and identification of Q-markers, analysis and quality management of risk evaluation were designed. Authors introduced a few new technologies and methodologies, such as DNA barcoding, chromatographic technologies, fingerprint analysis, chemical markers, bio-responses, risk management and solution for quality process control. The quality and process control models for herbal medicinal products were proposed and the transitivity and traceability system from raw materials to the finished products was constructed to improve the herbal quality from the entire supply and production chain. The transitivity and traceability system has been established based on quality markers, especially on how to control the production process under Good Engineering Practices, as well as to implement the risk management for quality and process control in herbal medicine production. Copyright © 2018 Elsevier GmbH. All rights reserved.

  12. Wine Traceability: A Data Model and Prototype in Albanian Context

    PubMed Central

    Vukatana, Kreshnik; Sevrani, Kozeta; Hoxha, Elira

    2016-01-01

    Vine traceability is a critical issue that has gained interest internationally. Quality control programs and schemes are mandatory in many countries including EU members and the USA. Albania has transformed most of the EU regulations on food into laws. Regarding the vine sector, the obligation of wine producers to keep traceability data is part of the legislation. The analysis on the interviews conducted with Albanian winemakers show that these data are actually recorded only in hard copy. Another fact that emerges from the interviews is that only two producers have implemented the ISO (International Organization for Standardization) standards on food. The purpose of this paper is to develop an agile and automated traceability system based on these standards. We propose a data model and system prototype that are described in the second and third section of this work. The data model is an adaption along the lines of the GS1 (Global Standards One) specifications for a wine supply chain. The proposed prototype has a key component that is mobile access to the information about wine through barcode technology. By using this mechanism the consumer obtains transparency on his expectations concerning the quality criteria. Another important component of the proposed system in this paper is a real-time notification module that works as an alert system when a risk is identified. This can help producers and authorities to have a rapid identification of a contaminated product. It is important in cases when recalling the product from the market or preventing it from reaching the consumer. PMID:28231105

  13. Evaluation of the implementation of new traceability and food safety requirements in the pig industry in eastern Australia.

    PubMed

    Hernández-Jover, M; Schembri, N; Toribio, J-A; Holyoake, P K

    2009-10-01

    To evaluate the implementation and barriers to adoption, among pig producers, of a newly introduced traceability and food safety system in Australia. Implementation of the PigPass national vendor declaration (NVD) linked to an on-farm quality assurance (QA) program was evaluated in May and December 2007 at saleyards and abattoirs in New South Wales, Victoria and Queensland. Four focus group discussions with saleyard producers were held between April and July 2007. Implementation of the PigPass system in terms of accurate completion of the form and QA accreditation was higher at the export abattoir than at the regional saleyard at the first audit (P < 0.01). Implementation increased at the second audit at the abattoirs, but little change with time was observed at saleyards. Approximately half of the producers at saleyards used photocopied PigPass forms, made at least one error (>64%), and many vendors did not appear to be QA-accredited. During focus groups, producers expressed the view that PigPass implementation improved animal and product traceability. They identified the associated costs and a perceived lack of support by information providers as obstacles for adoption. Improvement in the implementation of PigPass among producers marketing pigs at export abattoirs was observed during the 8-month period of the study. There is a need for a more uniform message to producers from government agencies on the importance of the PigPass NVD and QA and extension and education targeted toward producers supplying pigs to saleyards and domestic abattoirs to ensure compliance with the traceability requirements.

  14. Wine Traceability: A Data Model and Prototype in Albanian Context.

    PubMed

    Vukatana, Kreshnik; Sevrani, Kozeta; Hoxha, Elira

    2016-02-17

    Vine traceability is a critical issue that has gained interest internationally. Quality control programs and schemes are mandatory in many countries including EU members and the USA. Albania has transformed most of the EU regulations on food into laws. Regarding the vine sector, the obligation of wine producers to keep traceability data is part of the legislation. The analysis on the interviews conducted with Albanian winemakers show that these data are actually recorded only in hard copy. Another fact that emerges from the interviews is that only two producers have implemented the ISO (International Organization for Standardization) standards on food. The purpose of this paper is to develop an agile and automated traceability system based on these standards. We propose a data model and system prototype that are described in the second and third section of this work. The data model is an adaption along the lines of the GS1 (Global Standards One) specifications for a wine supply chain. The proposed prototype has a key component that is mobile access to the information about wine through barcode technology. By using this mechanism the consumer obtains transparency on his expectations concerning the quality criteria. Another important component of the proposed system in this paper is a real-time notification module that works as an alert system when a risk is identified. This can help producers and authorities to have a rapid identification of a contaminated product. It is important in cases when recalling the product from the market or preventing it from reaching the consumer.

  15. Coherent double-color interference microscope for traceable optical surface metrology

    NASA Astrophysics Data System (ADS)

    Malinovski, I.; França, R. S.; Bessa, M. S.; Silva, C. R.; Couceiro, I. B.

    2016-06-01

    Interference microscopy is an important field of dimensional surface metrology because it provides direct traceability of the measurements to the SI base unit definition of the metre. With a typical measurement range from micrometres to nanometres interference microscopy (IM) covers the gap between classic metrology and nanometrology, providing continuous transfer of dimensional metrology into new areas of nanoscience and nanotechnology. Therefore IM is considered to be an indispensable tool for traceable transfer of the metre unit to different instruments. We report here the metrological study of an absolute Linnik interference microscope (IM) based on two frequency stabilized lasers. The design permits the flexible use of both lasers for measurements depending on the demand of the concrete measurement task. By principle of operation IM is combination of imaging and phase-shifting interferometry (PSI). The traceability is provided by the wavelength reference, that is, a He-Ne 633 nm stabilized laser. The second laser source, that is, a Blue-Green 488 nm grating stabilized laser diode, is used for improvements of resolution, and also for resolving integer fringe discontinuities on sharp features of the surface. The IM was optimized for surface height metrology. We have performed the study of the systematic effects of the measurements. This study allowed us to improve the hardware and software of IM and to find corrections for main systematic errors. The IM is purposed for 1D to 3D height metrology and surface topography in an extended range from nanometres to micrometres. The advantages and disadvantages of the design and developed methods are discussed.

  16. Towards absolute quantification of allergenic proteins in food--lysozyme in wine as a model system for metrologically traceable mass spectrometric methods and certified reference materials.

    PubMed

    Cryar, Adam; Pritchard, Caroline; Burkitt, William; Walker, Michael; O'Connor, Gavin; Burns, Duncan Thorburn; Quaglia, Milena

    2013-01-01

    Current routine food allergen quantification methods, which are based on immunochemistry, offer high sensitivity but can suffer from issues of specificity and significant variability of results. MS approaches have been developed, but currently lack metrological traceability. A feasibility study on the application of metrologically traceable MS-based reference procedures was undertaken. A proof of concept involving proteolytic digestion and isotope dilution MS for quantification of protein allergens in a food matrix was undertaken using lysozyme in wine as a model system. A concentration of lysozyme in wine of 0.95 +/- 0.03 microg/g was calculated based on the concentrations of two peptides, confirming that this type of analysis is viable at allergenically meaningful concentrations. The challenges associated with this promising method were explored; these included peptide stability, chemical modification, enzymatic digestion, and sample cleanup. The method is suitable for the production of allergen in food certified reference materials, which together with the achieved understanding of the effects of sample preparation and of the matrix on the final results, will assist in addressing the bias of the techniques routinely used and improve measurement confidence. Confirmation of the feasibility of MS methods for absolute quantification of an allergenic protein in a food matrix with results traceable to the International System of Units is a step towards meaningful comparison of results for allergen proteins among laboratories. This approach will also underpin risk assessment and risk management of allergens in the food industry, and regulatory compliance of the use of thresholds or action levels when adopted.

  17. Implementation of Finite Rate Chemistry Capability in OVERFLOW

    NASA Technical Reports Server (NTRS)

    Olsen, M. E.; Venkateswaran, S.; Prabhu, D. K.

    2004-01-01

    An implementation of both finite rate and equilibrium chemistry have been completed for the OVERFLOW code, a chimera capable, complex geometry flow code widely used to predict transonic flow fields. The implementation builds on the computational efficiency and geometric generality of the solver.

  18. Effect of different carotenoid-containing diets on the vitamin A levels and colour parameters in Iberian pigs' tissues: utility as biomarkers of traceability.

    PubMed

    Álvarez, R; Vicario, I M; Meléndez-Martínez, A J; Alcalde, M J

    2014-10-01

    Retinol and fat colour parameters in Iberian pigs fed on different carotenoid-containing diets were assessed. Thirty animals in two groups were considered: Iberian breed pigs fed on acorns and grass (Montanera) and on concentrate (Cebo). Carotenoids and retinoids were analysed in the diets and in plasma, liver and perirenal fat of the animals by HPLC and HPLC-MS. Retinol levels in plasma and fat were similar in Montanera and Cebo animals. The utility of retonids and colour parameters as traceability index was also explored. Retinoids in liver classified correctly 93% of the animals according to their diet L* and hab. CIELAB parameters of the perirenal fat discriminated correctly 78.6% of the animals according to their diet. L* values for the Montanera animals were significantly different (P<0.01) from those fed on concentrate. It can be claimed that the liver retinol profile and fat colour parameters can be useful for feeding traceability purposes in Iberian pigs breed in Montanera and Cebo. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Traceability and Quality Control in Traditional Chinese Medicine: From Chemical Fingerprint to Two-Dimensional Barcode

    PubMed Central

    Cai, Yong; Li, Xiwen; Li, Mei; Chen, Xiaojia; Ni, Jingyun; Wang, Yitao

    2015-01-01

    Chemical fingerprinting is currently a widely used tool that enables rapid and accurate quality evaluation of Traditional Chinese Medicine (TCM). However, chemical fingerprints are not amenable to information storage, recognition, and retrieval, which limit their use in Chinese medicine traceability. In this study, samples of three kinds of Chinese medicines were randomly selected and chemical fingerprints were then constructed by using high performance liquid chromatography. Based on chemical data, the process of converting the TCM chemical fingerprint into two-dimensional code is presented; preprocess and filtering algorithm are also proposed aiming at standardizing the large amount of original raw data. In order to know which type of two-dimensional code (2D) is suitable for storing data of chemical fingerprints, current popular types of 2D codes are analyzed and compared. Results show that QR Code is suitable for recording the TCM chemical fingerprint. The fingerprint information of TCM can be converted into data format that can be stored as 2D code for traceability and quality control. PMID:26089936

  20. Improving integrity of on-line grammage measurement with traceable basic calibration.

    PubMed

    Kangasrääsiö, Juha

    2010-07-01

    The automatic control of grammage (basis weight) in paper and board production is based upon on-line grammage measurement. Furthermore, the automatic control of other quality variables such as moisture, ash content and coat weight, may rely on the grammage measurement. The integrity of Kr-85 based on-line grammage measurement systems was studied, by performing basic calibrations with traceably calibrated plastic reference standards. The calibrations were performed according to the EN ISO/IEC 17025 standard, which is a requirement for calibration laboratories. The observed relative measurement errors were 3.3% in the first time calibrations at the 95% confidence level. With the traceable basic calibration method, however, these errors can be reduced to under 0.5%, thus improving the integrity of on-line grammage measurements. Also a standardised algorithm, based on the experience from the performed calibrations, is proposed to ease the adjustment of the different grammage measurement systems. The calibration technique can basically be applied to all beta-radiation based grammage measurements. 2010 ISA. Published by Elsevier Ltd. All rights reserved.

  1. Force sensor characterization under sinusoidal excitations.

    PubMed

    Medina, Nieves; de Vicente, Jesús

    2014-10-06

    The aim in the current work is the development of a method to characterize force sensors under sinusoidal excitations using a primary standard as the source of traceability. During this work the influence factors have been studied and a method to minimise their contributions, as well as the corrections to be performed under dynamic conditions have been established. These results will allow the realization of an adequate characterization of force sensors under sinusoidal excitations, which will be essential for its further proper use under dynamic conditions. The traceability of the sensor characterization is based in the direct definition of force as mass multiplied by acceleration. To do so, the sensor is loaded with different calibrated loads and is maintained under different sinusoidal accelerations by means of a vibration shaker system that is able to generate accelerations up to 100 m/s2 with frequencies from 5 Hz up to 2400 Hz. The acceleration is measured by means of a laser vibrometer with traceability to the units of time and length. A multiple channel data acquisition system is also required to simultaneously acquire the electrical output signals of the involved instrument in real time.

  2. Processing uncertain RFID data in traceability supply chains.

    PubMed

    Xie, Dong; Xiao, Jie; Guo, Guangjun; Jiang, Tong

    2014-01-01

    Radio Frequency Identification (RFID) is widely used to track and trace objects in traceability supply chains. However, massive uncertain data produced by RFID readers are not effective and efficient to be used in RFID application systems. Following the analysis of key features of RFID objects, this paper proposes a new framework for effectively and efficiently processing uncertain RFID data, and supporting a variety of queries for tracking and tracing RFID objects. We adjust different smoothing windows according to different rates of uncertain data, employ different strategies to process uncertain readings, and distinguish ghost, missing, and incomplete data according to their apparent positions. We propose a comprehensive data model which is suitable for different application scenarios. In addition, a path coding scheme is proposed to significantly compress massive data by aggregating the path sequence, the position, and the time intervals. The scheme is suitable for cyclic or long paths. Moreover, we further propose a processing algorithm for group and independent objects. Experimental evaluations show that our approach is effective and efficient in terms of the compression and traceability queries.

  3. Safety and Traceability in Patient Healthcare through the Integration of RFID Technology for Intravenous Mixtures in the Prescription-Validation-Elaboration-Dispensation-Administration Circuit to Day Hospital Patients.

    PubMed

    Martínez Pérez, María; Vázquez González, Guillermo; Dafonte, Carlos

    2016-07-28

    This work presents the integration of the RFID technology with the aim of ensuring the traceability of patients and minimization of adverse events during the process of prescription-validation-elaboration-dispensation-administration of medication by means of the implementation of various passive and active WIFI RFID systems in the Pharmacy and Day Hospital services of the Complejo Hospitalario Universitario A Coruña. Obtaining patient traceability and using the patient/drug binomial during this process allows us to minimize the occurrence of adverse events. The key points in this work are the unmistakably unique identification and accurate real time location of the controlled items (patients and medication). RFID technology has proved to be invaluable in assisting with the everyday clinical practice of a hospital, and has been successfully implemented in this environment and others. In services such as the day hospital, the implementation of said technology is further justified by the high costs of the service and the high risk to the patient.

  4. Safety and Traceability in Patient Healthcare through the Integration of RFID Technology for Intravenous Mixtures in the Prescription-Validation-Elaboration-Dispensation-Administration Circuit to Day Hospital Patients

    PubMed Central

    Martínez Pérez, María; Vázquez González, Guillermo; Dafonte, Carlos

    2016-01-01

    This work presents the integration of the RFID technology with the aim of ensuring the traceability of patients and minimization of adverse events during the process of prescription-validation-elaboration-dispensation-administration of medication by means of the implementation of various passive and active WIFI RFID systems in the Pharmacy and Day Hospital services of the Complejo Hospitalario Universitario A Coruña. Obtaining patient traceability and using the patient/drug binomial during this process allows us to minimize the occurrence of adverse events. The key points in this work are the unmistakably unique identification and accurate real time location of the controlled items (patients and medication). RFID technology has proved to be invaluable in assisting with the everyday clinical practice of a hospital, and has been successfully implemented in this environment and others. In services such as the day hospital, the implementation of said technology is further justified by the high costs of the service and the high risk to the patient. PMID:27483269

  5. About “SI” Traceability of Micromasses And/or Microforces

    NASA Astrophysics Data System (ADS)

    Vâlcu, Adriana; Ştefănescu, Dan Mihai

    Over the last period, increasing attention has been paid to measurement of small forces which play a more important role in nanotechnology and other significant areas such as MEMS (Micro-Electro-Mechanical Systems) and NEMS (nano-electro-mechanical systems) which can be found into everyday products (mobile phones, MP3 players, PCs, cars). In this respect, the development of mass standards and measurement techniques below the current limit of 1 milligram is vital to provide traceability to the SI for such measurements. In Romania, the Mass laboratory of INM considered it necessary to extend the dissemination of the mass unit below 1 mg, in order to meet current needs. Using the subdivision method and starting from the national prototype kilogram No. 2, all necessary experiments were performed for the first time in Romania to extend mass unit traceability till 100 μg. This extension also supports the provision of mass calibrations for low force measurements. The associated measurement procedure and measurement uncertainty results obtained in the calibration are described. In the article are also presented some of the worldwide methods currently used for measuring small forces.

  6. Processing Uncertain RFID Data in Traceability Supply Chains

    PubMed Central

    Xie, Dong; Xiao, Jie

    2014-01-01

    Radio Frequency Identification (RFID) is widely used to track and trace objects in traceability supply chains. However, massive uncertain data produced by RFID readers are not effective and efficient to be used in RFID application systems. Following the analysis of key features of RFID objects, this paper proposes a new framework for effectively and efficiently processing uncertain RFID data, and supporting a variety of queries for tracking and tracing RFID objects. We adjust different smoothing windows according to different rates of uncertain data, employ different strategies to process uncertain readings, and distinguish ghost, missing, and incomplete data according to their apparent positions. We propose a comprehensive data model which is suitable for different application scenarios. In addition, a path coding scheme is proposed to significantly compress massive data by aggregating the path sequence, the position, and the time intervals. The scheme is suitable for cyclic or long paths. Moreover, we further propose a processing algorithm for group and independent objects. Experimental evaluations show that our approach is effective and efficient in terms of the compression and traceability queries. PMID:24737978

  7. Nuclear reference materials to meet the changing needs of the global nuclear community

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, H.R.; Gradle, C.G.; Narayanan, U.I.

    New Brunswick Laboratory (NBL) serves as the US Government`s Certifying Authority for nuclear reference materials and measurement calibration standards. In this role, NBL provides nuclear reference materials certified for chemical and/or isotopic compositions traceable to a nationally accepted, internationally compatible reference base. Emphasis is now changing as to the types of traceable nuclear reference materials needed as operations change within the Department of Energy (DOE) complex and at nuclear facilities around the world. Environmental and waste minimization issues, facilities and materials transitioning from processing to storage modes with corresponding changes in the types of measurements being performed, emphasis on requirementsmore » for characterization of waste materials, difficulties in transporting nuclear materials, and International factors, including International Atomic Energy Agency (IAEA) inspection of excess US nuclear materials, are all contributing influences. During these changing times, ft is critical that traceable reference materials be provided for calibration or validation of the performance of measurement systems. This paper will describe actions taken and planned to meet the changing reference material needs of the global nuclear community.« less

  8. Technology Infusion Challenges from a Decision Support Perspective

    NASA Technical Reports Server (NTRS)

    Adumitroaie, V.; Weisbin, C. R.

    2009-01-01

    In a restricted science budget environment and increasingly numerous required technology developments, the technology investment decisions within NASA are objectively more and more difficult to make such that the end results are satisfying the technical objectives and all the organizational constraints. Under these conditions it is rationally desirable to build an investment portfolio, which has the highest possible technology infusion rate. Arguably the path to infusion is subject to many influencing factors, but here only the challenges associated with the very initial stages are addressed: defining the needs and the subsequent investment decision-support process. It is conceivable that decision consistency and possibly its quality suffer when the decision-making process has limited or no traceability. This paper presents a structured decision-support framework aiming to provide traceable, auditable, infusion- driven recommendations towards a selection process in which these recommendations are used as reference points in further discussions among stakeholders. In this framework addressing well-defined requirements, different measures of success can be defined based on traceability to specific selection criteria. As a direct result, even by using simplified decision models the likelihood of infusion can be probed and consequently improved.

  9. A Verification-Driven Approach to Traceability and Documentation for Auto-Generated Mathematical Software

    NASA Technical Reports Server (NTRS)

    Denney, Ewen W.; Fischer, Bernd

    2009-01-01

    Model-based development and automated code generation are increasingly used for production code in safety-critical applications, but since code generators are typically not qualified, the generated code must still be fully tested, reviewed, and certified. This is particularly arduous for mathematical and control engineering software which requires reviewers to trace subtle details of textbook formulas and algorithms to the code, and to match requirements (e.g., physical units or coordinate frames) not represented explicitly in models or code. Both tasks are complicated by the often opaque nature of auto-generated code. We address these problems by developing a verification-driven approach to traceability and documentation. We apply the AUTOCERT verification system to identify and then verify mathematical concepts in the code, based on a mathematical domain theory, and then use these verified traceability links between concepts, code, and verification conditions to construct a natural language report that provides a high-level structured argument explaining why and how the code uses the assumptions and complies with the requirements. We have applied our approach to generate review documents for several sub-systems of NASA s Project Constellation.

  10. Pathways to increase consumer trust in meat as a safe and wholesome food.

    PubMed

    Gellynck, Xavier; Verbeke, Wim; Vermeire, Bert

    2006-09-01

    This paper focuses on the effect of information about meat safety and wholesomeness on consumer trust based on several studies with data collected in Belgium. The research is grounded in the observation that despite the abundant rise of information through labelling, traceability systems and quality assurance schemes, the effect on consumer trust in meat as a safe and wholesome product is only limited. The overload and complexity of information on food products results in misunderstanding and misinterpretation. Functional traceability attributes such as organisational efficiency and chain monitoring are considered to be highly important but not as a basis for market segmentation. However, process traceability attributes such as origin and production method are of interest for particular market segments as a response to meat quality concerns. Quality assurance schemes and associated labels have a poor impact on consumers' perception. It is argued that the high interest of retailers in such schemes is driven by procurement management efficiency rather than safety or overall quality. Future research could concentrate on the distribution of costs and benefits associated with meat quality initiatives among the chain participants.

  11. Hg0 and HgCl2 Reference Gas Standards: ?NIST Traceability ...

    EPA Pesticide Factsheets

    EPA and NIST have collaborated to establish the necessary procedures for establishing the required NIST traceability of commercially-provided Hg0 and HgCl2 reference generators. This presentation will discuss the approach of a joint EPA/NIST study to accurately quantify the true concentrations of Hg0 and HgCl2 reference gases produced from high quality, NIST-traceable, commercial Hg0 and HgCl2 generators. This presentation will also discuss the availability of HCl and Hg0 compressed reference gas standards as a result of EPA's recently approved Alternative Methods 114 and 118. Gaseous elemental mercury (Hg0) and oxidized mercury (HgCl2) reference standards are integral to the use of mercury continuous emissions monitoring systems (Hg CEMS) for regulatory compliance emissions monitoring. However, a quantitative disparity of approximately 7-10% has been observed between commercial Hg0 and HgCl2 reference gases which currently limits the use of (HgCl2) reference gas standards. Resolving this disparity would enable the expanded use of (HgCl2) reference gas standards for regulatory compliance purposes.

  12. Making objective summaries of climate model behavior more accessible

    NASA Astrophysics Data System (ADS)

    Gleckler, P. J.

    2016-12-01

    For multiple reasons, a more efficient and systematic evaluation of publically available climate model simulations is urgently needed. The IPCC, national assessments, and an assortment of other public and policy-driven needs place taxing demands on researchers. While cutting edge research is essential to meeting these needs, so too are results from well-established analysis, and these should be more efficiently produced, widely accessible, and be highly traceable. Furthermore, the number of simulations used by the research community is already large and expected to dramatically increase with the 6th phase of the Coupled Model Intercomparison Project (CMIP6). To help meet the demands on the research community and synthesize results from the rapidly expanding number and complexity of model simulations, well-established characteristics from all CMIP DECK (Diagnosis, Evaluation and Characterization of Klima) experiments will be routinely produced and made accessible. This presentation highlights the PCMDI Metrics Package (PMP), a capability that is designed to provide a diverse suite of objective summary statistics across spatial and temporal scales, gauging the agreement between models and observations. In addition to the PMP, ESMValTool is being developed to broadly diagnose CMIP simulations, and a variety of other packages target specialized sets of analysis. The challenges and opportunities of working towards coordinating these community-based capabilities will be discussed.

  13. Evaluation of a low-cost 3D sound system for immersive virtual reality training systems.

    PubMed

    Doerr, Kai-Uwe; Rademacher, Holger; Huesgen, Silke; Kubbat, Wolfgang

    2007-01-01

    Since Head Mounted Displays (HMD), datagloves, tracking systems, and powerful computer graphics resources are nowadays in an affordable price range, the usage of PC-based "Virtual Training Systems" becomes very attractive. However, due to the limited field of view of HMD devices, additional modalities have to be provided to benefit from 3D environments. A 3D sound simulation can improve the capabilities of VR systems dramatically. Unfortunately, realistic 3D sound simulations are expensive and demand a tremendous amount of computational power to calculate reverberation, occlusion, and obstruction effects. To use 3D sound in a PC-based training system as a way to direct and guide trainees to observe specific events in 3D space, a cheaper alternative has to be provided, so that a broader range of applications can take advantage of this modality. To address this issue, we focus in this paper on the evaluation of a low-cost 3D sound simulation that is capable of providing traceable 3D sound events. We describe our experimental system setup using conventional stereo headsets in combination with a tracked HMD device and present our results with regard to precision, speed, and used signal types for localizing simulated sound events in a virtual training environment.

  14. Traceability of sulfonamide antibiotic treatment by immunochemical analysis of farm animal hair samples.

    PubMed

    Adrian, Javier; Gratacós-Cubarsí, Marta; Sánchez-Baeza, Francisco; Garcia Regueiro, Jose-Antonio; Castellari, Massimo; Marco, M-Pilar

    2009-10-01

    The use of hair to trace use of unauthorized substances, therapeutic agents, or their misuse is becoming very attractive since residues can be detected for a long time after treatment. For this purpose, an indirect enzyme-linked immunosorbent assay (ELISA) has been evaluated for its capability to trace sulfonamide antibiotic treatment by analyzing cattle and pig hair samples. Pigmented and nonpigmented hair samples from control and sulfamethazine (SMZ)-treated pigs and calves were collected, extracted under different alkaline conditions, and analyzed by ELISA after just diluting the extracts with the assay buffer. Data analysis following the European recommendations for screening methods demonstrates that the ELISA can detect SMZ in hair samples with a limit of detection (90% of the zero dose (IC(90))) between 30 and 75 ng g(-1). The same samples have been analyzed by HPLC after a dual solid-phase extraction. The ELISA results matched very well those obtained by the chromatographic method, demonstrating that the immunochemical method can be used as a screening tool to trace animal treatments. Between the benefits of this method are the possibility to directly analyze hair extracts with sufficient detectability and its high-throughput capability. Preliminary validation data are reported using an experimental approach inspired on the Commission Decision 2002/657/EC criteria for screening methods.

  15. Requirements, Verification, and Compliance (RVC) Database Tool

    NASA Technical Reports Server (NTRS)

    Rainwater, Neil E., II; McDuffee, Patrick B.; Thomas, L. Dale

    2001-01-01

    This paper describes the development, design, and implementation of the Requirements, Verification, and Compliance (RVC) database used on the International Space Welding Experiment (ISWE) project managed at Marshall Space Flight Center. The RVC is a systems engineer's tool for automating and managing the following information: requirements; requirements traceability; verification requirements; verification planning; verification success criteria; and compliance status. This information normally contained within documents (e.g. specifications, plans) is contained in an electronic database that allows the project team members to access, query, and status the requirements, verification, and compliance information from their individual desktop computers. Using commercial-off-the-shelf (COTS) database software that contains networking capabilities, the RVC was developed not only with cost savings in mind but primarily for the purpose of providing a more efficient and effective automated method of maintaining and distributing the systems engineering information. In addition, the RVC approach provides the systems engineer the capability to develop and tailor various reports containing the requirements, verification, and compliance information that meets the needs of the project team members. The automated approach of the RVC for capturing and distributing the information improves the productivity of the systems engineer by allowing that person to concentrate more on the job of developing good requirements and verification programs and not on the effort of being a "document developer".

  16. Two generators to produce SI-traceable reference gas mixtures for reactive compounds at atmospheric levels

    NASA Astrophysics Data System (ADS)

    Pascale, C.; Guillevic, M.; Ackermann, A.; Leuenberger, D.; Niederhauser, B.

    2017-12-01

    To answer the needs of air quality and climate monitoring networks, two new gas generators were developed and manufactured at METAS in order to dynamically generate SI-traceable reference gas mixtures for reactive compounds at atmospheric concentrations. The technical features of the transportable generators allow for the realization of such gas standards for reactive compounds (e.g. NO2, volatile organic compounds) in the nmol · mol-1 range (ReGaS2), and fluorinated gases in the pmol ṡ mol-1 range (ReGaS3). The generation method is based on permeation and dynamic dilution. The transportable generators have multiple individual permeation chambers allowing for the generation of mixtures containing up to five different compounds. This mixture is then diluted using mass flow controllers, thus making the production process adaptable to generate the required amount of substance fraction. All parts of ReGaS2 in contact with the gas mixture are coated to reduce adsorption/desorption processes. Each input parameter required to calculate the generated amount of substance fraction is calibrated with SI-primary standards. The stability and reproducibility of the generated amount of substance fractions were tested with NO2 for ReGaS2 and HFC-125 for ReGaS3. They demonstrate stability over 1-4 d better than 0.4% and 0.8%, respectively, and reproducibility better than 0.7% and 1%, respectively. Finally, the relative expanded uncertainty of the generated amount of substance fraction is smaller than 3% with the major contributions coming from the uncertainty of the permeation rate and/or of the purity of the matrix gas. These relative expanded uncertainties meet then the needs of the data quality objectives fixed by the World Meteorological Organization.

  17. Comparison of The Dimensional Stability of Kel-F 81 and Neoflon CTFE M400H Polychlorotrifluoroethylenes Used in Valve Seat Application

    NASA Technical Reports Server (NTRS)

    Waller, Jess M.; Beeson, Harold D.; Newton, Barry E.; Fries, Joseph (Technical Monitor)

    2000-01-01

    The dimensional stability of polychlorotrifluoroethylene (PCTFE) valve seats used in oxygen regulator applications was determined by thermomechanical analysis (TMA). Two traceable grades of PCTFE were tested; Kel-F 81 and Neoflon CTFE M400H. For these particular resins, the effect of percent crystallinity, zero strength time (ZST) molecular weight, resin grade, process history (compression-molded versus extruded) on the dimensional stability and annealing behavior was determined. In addition to the traceable Kel-F 81 and Neoflon CTFE M400H grades, actual PCI'PH valve seats of differing geometry and design were tested by TMA. The PCTFE valve seats were of unspecified resin grade, although certain inferences about the grade could be drawn based on knowledge of the valve seat fabrication date. Results consistently revealed dimensional instability of varying magnitude at temperatures ranging from 40 to 70 degrees Celsius. Furthermore, some of the pre- 1 995 seats appeared to be more dimensionally stable than those fabricated after 1995. The TMA results are discussed in the context of several proposed ignition mechanisms; namely, particle impact, presence of contaminant oils and fibers, and localized heating by flow friction and/or resonance. The effect of metal constraint on the dimensional stability of PCTFE is also discussed. Finally, the effect of percent crystallinity, ZST molecular weight, resin grade, process history (compression-molded versus extruded) on the AIT, delta Hc and impact sensitivity of various types of Neoflon CTFE M400H was determined using Kel-F 81 as a control. Results show that the AIT, delta Hc and impact sensitivity were essentially independent of Neoflon CTFE process history and structure.

  18. Measurement uncertainty budget of an interferometric flow velocity sensor

    NASA Astrophysics Data System (ADS)

    Bermuske, Mike; Büttner, Lars; Czarske, Jürgen

    2017-06-01

    Flow rate measurements are a common topic for process monitoring in chemical engineering and food industry. To achieve the requested low uncertainties of 0:1% for flow rate measurements, a precise measurement of the shear layers of such flows is necessary. The Laser Doppler Velocimeter (LDV) is an established method for measuring local flow velocities. For exact estimation of the flow rate, the flow profile in the shear layer is of importance. For standard LDV the axial resolution and therefore the number of measurement points in the shear layer is defined by the length of the measurement volume. A decrease of this length is accompanied by a larger fringe distance variation along the measurement axis which results in a rise of the measurement uncertainty for the flow velocity (uncertainty relation between spatial resolution and velocity uncertainty). As a unique advantage, the laser Doppler profile sensor (LDV-PS) overcomes this problem by using two fan-like fringe systems to obtain the position of the measured particles along the measurement axis and therefore achieve a high spatial resolution while it still offers a low velocity uncertainty. With this technique, the flow rate can be estimated with one order of magnitude lower uncertainty, down to 0:05% statistical uncertainty.1 And flow profiles especially in film flows can be measured more accurately. The problem for this technique is, in contrast to laboratory setups where the system is quite stable, that for industrial applications the sensor needs a reliable and robust traceability to the SI units, meter and second. Small deviations in the calibration can, because of the highly position depending calibration function, cause large systematic errors in the measurement result. Therefore, a simple, stable and accurate tool is needed, that can easily be used in industrial surroundings to check or recalibrate the sensor. In this work, different calibration methods are presented and their influences to the measurement uncertainty budget of the sensor is discussed. Finally, generated measurement results for the film flow of an impinging jet cleaning experiment are presented.

  19. Implementation of Flow Tripping Capability in the USM3D Unstructured Flow Solver

    NASA Technical Reports Server (NTRS)

    Pandya, Mohagna J.; Abdol-Harrid, Khaled S.; Campbell, Richard L.; Frink, Neal T.

    2006-01-01

    A flow tripping capability is added to an established NASA tetrahedral unstructured parallel Navier-Stokes flow solver, USM3D. The capability is based on prescribing an appropriate profile of turbulence model variables to energize the boundary layer in a plane normal to a specified trip region on the body surface. We demonstrate this approach using the k-e two-equation turbulence model of USM3D. Modification to the solution procedure primarily consists of developing a data structure to identify all unstructured tetrahedral grid cells located in the plane normal to a specified surface trip region and computing a function based on the mean flow solution to specify the modified profile of the turbulence model variables. We leverage this data structure and also show an adjunct approach that is based on enforcing a laminar flow condition on the otherwise fully turbulent flow solution in user specified region. The latter approach is applied for the solutions obtained using other one- and two-equation turbulence models of USM3D. A key ingredient of the present capability is the use of a graphical user-interface tool PREDISC to define a trip region on the body surface in an existing grid. Verification of the present modifications is demonstrated on three cases, namely, a flat plate, the RAE2822 airfoil, and the DLR F6 wing-fuselage configuration.

  20. Implementation of Flow Tripping Capability in the USM3D Unstructured Flow Solver

    NASA Technical Reports Server (NTRS)

    Pandya, Mohagna J.; Abdol-Hamid, Khaled S.; Campbell, Richard L.; Frink, Neal T.

    2006-01-01

    A flow tripping capability is added to an established NASA tetrahedral unstructured parallel Navier-Stokes flow solver, USM3D. The capability is based on prescribing an appropriate profile of turbulence model variables to energize the boundary layer in a plane normal to a specified trip region on the body surface. We demonstrate this approach using the k-epsilon two-equation turbulence model of USM3D. Modification to the solution procedure primarily consists of developing a data structure to identify all unstructured tetrahedral grid cells located in the plane normal to a specified surface trip region and computing a function based on the mean flow solution to specify the modified profile of the turbulence model variables. We leverage this data structure and also show an adjunct approach that is based on enforcing a laminar flow condition on the otherwise fully turbulent flow solution in user-specified region. The latter approach is applied for the solutions obtained using other one-and two-equation turbulence models of USM3D. A key ingredient of the present capability is the use of a graphical user-interface tool PREDISC to define a trip region on the body surface in an existing grid. Verification of the present modifications is demonstrated on three cases, namely, a flat plate, the RAE2822 airfoil, and the DLR F6 wing-fuselage configuration.

  1. RBS as a new primary direct reference method for measuring quantity of material

    NASA Astrophysics Data System (ADS)

    Jeynes, C.

    2017-09-01

    The quantity of material in thin films can be measured reliably, non-destructively, and at an absolute traceable accuracy with a combined standard uncertainty of 1% by Rutherford backscattering spectrometry (RBS). We have demonstrated a measurement protocol for the determination of quantity of material by RBS that has been accredited at this accuracy to the ISO 17025 standard by the United Kingdom Accreditation Service (UKAS). The method is entirely traceable to SI units relying on no artefacts, and thus qualifies as a primary direct reference method as defined by the ISO Guide 35:1985 (paragraph 9.4.1).

  2. Soft fruit traceability in food matrices using real-time PCR.

    PubMed

    Palmieri, Luisa; Bozza, Elisa; Giongo, Lara

    2009-02-01

    Food product authentication provides a means of monitoring and identifying products for consumer protection and regulatory compliance. There is a scarcity of analytical methods for confirming the identity of fruit pulp in products containing Soft Fruit. In the present work we have developed a very sensible qualitative and quantitative method to determine the presence of berry DNAs in different food matrices. To our knowledge, this is the first study that shows the applicability, to Soft Fruit traceability, of melting curve analysis and multiplexed fluorescent probes, in a Real-Time PCR platform. This methodology aims to protect the consumer from label misrepresentation.

  3. Space station data system analysis/architecture study. Task 1: Functional requirements definition, DR-5. Appendix: Requirements data base

    NASA Technical Reports Server (NTRS)

    1985-01-01

    Appendix A contains data that characterize the system functions in sufficient depth as to determine the requirements for the Space Station Data System (SSDS). This data is in the form of: (1) top down traceability report; (2) bottom up traceability report; (3) requirements data sheets; and (4) cross index of requirements paragraphs of the source documents and the requirements numbers. A data base users guide is included that interested parties can use to access the requirements data base and get up to date information about the functions.

  4. Application of RFID in the area of agricultural products quality traceability and tracking and the anti-collision algorithm

    NASA Astrophysics Data System (ADS)

    Wang, Zu-liang; Zhang, Ting; Xie, Shi-yang

    2017-01-01

    In order to improve the agricultural tracing efficiency and reduce tracking and monitoring cost, agricultural products quality tracking and tracing based on Radio-Frequency Identification(RFID) technology is studied, then tracing and tracking model is set up. Three-layer structure model is established to realize the high quality of agricultural products traceability and tracking. To solve the collision problems between multiple RFID tags and improve the identification efficiency a new reservation slot allocation mechanism is proposed. And then we analyze and optimize the parameter by numerical simulation method.

  5. Field campaigns of the autonomous, closed-path, airborne TDLAS Hygrometer SEALDH-II and traceability to the German Primary Humidity Standards.

    NASA Astrophysics Data System (ADS)

    Buchholz, Bernhard; Ebert, Volker

    2014-05-01

    Airborne hygrometry is often demanded in scientific flight campaigns to provide datasets for environmental modeling or to correct for water vapor dilution or cross sensitivity effects in other gas analytical techniques. Water vapor measurements, however, are quite challenging due to the large dynamic range in the atmosphere (between 2 and 40000 ppmv) and the high spatio-temporal variability. Airborne hygrometers therefore need to combine a large measurement range with high temporal resolution to resolve - at typical airspeeds of 500 to 900 km/h - atmospheric gradients of several 1000 ppmv/s. Especially during the ascent into the upper troposphere, hygrometers need to work at high gas exchange rates to minimize water vapor adsorption effects. On the other hand, water vapor sensors are difficult to calibrate due to the strong water adsorption and the lack of bottled reference gas standards, which requires pre- or/and post-flight field calibrations. Recently in-flight calibration using an airborne H2O generator was demonstrated, which minimizes calibration drift but still imposes a lot of additional work and hardware to the experiments, since these kind of calibrations just transfer the accuracy level issues to the in-flight calibration-source. To make things worse, the low gas flow (1-5 std l/min, compared with up to 100 std l/min in flight for fast response instruments) adheres critical questions of wall absorption/desorption of the source and instrument even during the calibration process. The national metrological institutes (NMIs) maintain a global metrological water vapor scale which is defined via national primary humidity generators. These provide for calibration purposes well-defined, accurate water vapor samples of excellent comparability and stability traced back to the SI-units. The humidity calibration chain is maintained via high accuracy (but rather slow) Dew-Point-Mirror-Hygrometers as transfer standards. These provide a traceable performance and calibration link to any industrial or research laboratory hygrometer. To establish metrological traceability in field and particular in airborne hygrometers is however challenging and requires fast, field-compatible, metrologically qualified transfer hygrometry standards to link the metrological and the environmental sciences water scales. The SEALDH (Selective Extractive Airborne Laser Diode Hygrometer) development started 3 years ago and aims at filling this gap by using Tunable Diode Laser Absorption Spectroscopy (TDLAS) with a special, calibration-free data evaluation [1]. Previously developed, laboratory-based TDLAS instruments, such as [2] [3], were starting points to develop an autonomously operating, extractive water vapor sensor in a compact 19' 4 HU form factor. This new airborne package and far-reaching developments [4] in hard- and software allow an autonomous, low maintenance, airborne operation. SEALDH-II can be used in a calibration-free field sensor mode (with an absolute, metrologically defined uncertainty of 4.3% +- 3ppmv). The response time is mainly limited by the gas flow and significantly below 1 sec with a precision down to 0.08 ppmv (1σ, 1sec) measured at 600 ppmv and 1000 hPa. The excellent long-term stability of SEALDH-II (

  6. Comparison of intersecting pedestrian flows based on experiments

    NASA Astrophysics Data System (ADS)

    Zhang, J.; Seyfried, A.

    2014-07-01

    Intersections of pedestrian flows feature multiple types, varying in the numbers of flow directions as well as intersecting angles. In this article results from intersecting flow experiments with two different intersecting angles are compared. To analyze the transport capabilities the Voronoi method is used to resolve the fine structure of the resulting velocity-density relations and spatial dependence of the measurements. The fundamental diagrams of various flow types are compared and show no apparent difference with respect to the intersecting angle 90° and 180°. This result indicates that head-on conflicts of different types of flow have the same influence on the transport properties of the system, which demonstrates the high self-organization capabilities of pedestrians.

  7. Development and integration of sub-hourly rainfall-runoff modeling capability within a watershed model

    USDA-ARS?s Scientific Manuscript database

    Increasing urbanization changes runoff patterns to be flashy and instantaneous with decreased base flow. A model with the ability to simulate sub-daily rainfall–runoff processes and continuous simulation capability is required to realistically capture the long-term flow and water quality trends in w...

  8. Software for Analyzing Laminar-to-Turbulent Flow Transitions

    NASA Technical Reports Server (NTRS)

    Chang, Chau-Lyan

    2004-01-01

    Software assurance is the planned and systematic set of activities that ensures that software processes and products conform to requirements, standards, and procedures. Examples of such activities are the following: code inspections, unit tests, design reviews, performance analyses, construction of traceability matrices, etc. In practice, software development projects have only limited resources (e.g., schedule, budget, and availability of personnel) to cover the entire development effort, of which assurance is but a part. Projects must therefore select judiciously from among the possible assurance activities. At its heart, this can be viewed as an optimization problem; namely, to determine the allocation of limited resources (time, money, and personnel) to minimize risk or, alternatively, to minimize the resources needed to reduce risk to an acceptable level. The end result of the work reported here is a means to optimize quality-assurance processes used in developing software. This is achieved by combining two prior programs in an innovative manner

  9. Study on propellant dynamics during docking

    NASA Technical Reports Server (NTRS)

    Feng, G. C.; Robertson, S. J.

    1972-01-01

    The marker-and-cell numerical technique was applied to the study of axisymmetric and two-dimensional flow of liquid in containers under low gravity conditions. The purpose of the study was to provide the capability for numerically simulating liquid propellant motion in partially filled containers during a docking maneuver in orbit. A computer program to provide this capability for axisymmetric and two-dimensional flow was completed and computations were made for a number of hypothetical flow conditions.

  10. Metrological traceability and harmonization of medical tests: a quantum leap forward is needed to keep pace with globalization and stringent IVD-regulations in the 21st century!

    PubMed

    Cobbaert, Christa; Smit, Nico; Gillery, Philippe

    2018-05-07

    In our efforts to advance the profession and practice of clinical laboratory medicine, strong coordination and collaboration are needed more than ever before. At the dawn of the 21st century, medical laboratories are facing many unmet clinical needs, a technological revolution promising a plethora of better biomarkers, financial constraints, a growing scarcity of well-trained laboratory technicians and a sharply increasing number of International Organization for Standardization guidelines and new regulations to which medical laboratories should comply in order to guarantee safety and effectiveness of medical test results. Although this is a global trend, medical laboratories across continents and countries are in distinct phases and experience various situations. A universal underlying requirement for safe and global use of medical test results is the standardization and harmonization of test results. Since two decades and after a number of endeavors on standardization/harmonization of medical tests, it is time to reflect on the effectiveness of the approaches used. To keep laboratory medicine sustainable, viable and affordable, clarification of the promises of metrological traceability of test results for improving sick and health care, realization of formal commitment among all stakeholders of the metrological traceability chain and preparation of a joint and global plan for action are essential prerequisites. Policy makers and regulators should not only overwhelm the diagnostic sector with oversight and regulations but should also create the conditions by establishing a global professional forum for anchoring the metrological traceability concept in the medical test domain. Even so, professional societies should have a strong voice in their (inter-) national governments to negotiate long-lasting public policy commitment and funds for global standardization of medical tests.

  11. Development of genomic microsatellite multiplex PCR using dye-labeled universal primer and its validation in pedigree analysis of Pacific oyster ( Crassostrea gigas)

    NASA Astrophysics Data System (ADS)

    Liu, Ting; Li, Qi; Song, Junlin; Yu, Hong

    2017-02-01

    There is an increasing requirement for traceability of aquaculture products, both for consumer protection and for food safety. There are high error rates in the conventional traceability systems depending on physical labels. Genetic traceability technique depending on DNA-based tracking system can overcome this problem. Genealogy information is essential for genetic traceability, and microsatellite DNA marker is a good choice for pedigree analysis. As increasing genotyping throughput of microsatellites, microsatellite multiplex PCR has become a fast and cost-effective technique. As a commercially important cultured aquatic species, Pacific oyster Crassostrea gigas has the highest global production. The objective of this study was to develop microsatellite multiplex PCR panels with dye-labeled universal primer for pedigree analysis in C. gigas, and these multiplex PCRs were validated using 12 full-sib families with known pedigrees. Here we developed six informative multiplex PCRs using 18 genomic microsatellites in C. gigas. Each multiplex panel contained a single universal primer M13(-21) used as a tail on each locus-specific forward primer and a single universal primer M13(-21) labeled with fluorophores. The polymorphisms of the markers were moderate, with an average of 10.3 alleles per locus and average polymorphic information content of 0.740. The observed heterozygosity per locus ranged from 0.492 to 0.822. Cervus simulations revealed that the six panels would still be of great value when massive families were analysed. Pedigree analysis of real offspring demonstrated that 100% of the offspring were unambiguously allocated to their parents when two multiplex PCRs were used. The six sets of multiplex PCRs can be an important tool for tracing cultured individuals, population genetic analysis, and selective breeding program in C. gigas.

  12. Divergent predictions of carbon storage between two global land models: attribution of the causes through traceability analysis

    NASA Astrophysics Data System (ADS)

    Rafique, Rashid; Xia, Jianyang; Hararuk, Oleksandra; Asrar, Ghassem R.; Leng, Guoyong; Wang, Yingping; Luo, Yiqi

    2016-07-01

    Representations of the terrestrial carbon cycle in land models are becoming increasingly complex. It is crucial to develop approaches for critical assessment of the complex model properties in order to understand key factors contributing to models' performance. In this study, we applied a traceability analysis which decomposes carbon cycle models into traceable components, for two global land models (CABLE and CLM-CASA') to diagnose the causes of their differences in simulating ecosystem carbon storage capacity. Driven with similar forcing data, CLM-CASA' predicted ˜ 31 % larger carbon storage capacity than CABLE. Since ecosystem carbon storage capacity is a product of net primary productivity (NPP) and ecosystem residence time (τE), the predicted difference in the storage capacity between the two models results from differences in either NPP or τE or both. Our analysis showed that CLM-CASA' simulated 37 % higher NPP than CABLE. On the other hand, τE, which was a function of the baseline carbon residence time (τ'E) and environmental effect on carbon residence time, was on average 11 years longer in CABLE than CLM-CASA'. This difference in τE was mainly caused by longer τ'E of woody biomass (23 vs. 14 years in CLM-CASA'), and higher proportion of NPP allocated to woody biomass (23 vs. 16 %). Differences in environmental effects on carbon residence times had smaller influences on differences in ecosystem carbon storage capacities compared to differences in NPP and τ'E. Overall, the traceability analysis showed that the major causes of different carbon storage estimations were found to be parameters setting related to carbon input and baseline carbon residence times between two models.

  13. Divergent predictions of carbon storage between two global land models: Attribution of the causes through traceability analysis

    DOE PAGES

    Rafique, Rashid; Xia, Jianyang; Hararuk, Oleksandra; ...

    2016-07-29

    Representations of the terrestrial carbon cycle in land models are becoming increasingly complex. It is crucial to develop approaches for critical assessment of the complex model properties in order to understand key factors contributing to models' performance. In this study, we applied a traceability analysis which decomposes carbon cycle models into traceable components, for two global land models (CABLE and CLM-CASA') to diagnose the causes of their differences in simulating ecosystem carbon storage capacity. Driven with similar forcing data, CLM-CASA' predicted – 31 % larger carbon storage capacity than CABLE. Since ecosystem carbon storage capacity is a product of net primary productivitymore » (NPP) and ecosystem residence time ( τ E), the predicted difference in the storage capacity between the two models results from differences in either NPP or τ E or both. Our analysis showed that CLM-CASA'simulated 37 % higher NPP than CABLE. On the other hand, τ E, which was a function of the baseline carbon residence time ( τ' E) and environmental effect on carbon residence time, was on average 11 years longer in CABLE than CLM-CASA'. This difference in τ E was mainly caused by longer τ' E of woody biomass (23 vs. 14 years in CLM-CASA'), and higher proportion of NPP allocated to woody biomass (23 vs. 16 %). Differences in environmental effects on carbon residence times had smaller influences on differences in ecosystem carbon storage capacities compared to differences in NPP and τ' E. Altogether, the traceability analysis showed that the major causes of different carbon storage estimations were found to be parameters setting related to carbon input and baseline carbon residence times between two models.« less

  14. Divergent predictions of carbon storage between two global land models: Attribution of the causes through traceability analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rafique, Rashid; Xia, Jianyang; Hararuk, Oleksandra

    Representations of the terrestrial carbon cycle in land models are becoming increasingly complex. It is crucial to develop approaches for critical assessment of the complex model properties in order to understand key factors contributing to models' performance. In this study, we applied a traceability analysis which decomposes carbon cycle models into traceable components, for two global land models (CABLE and CLM-CASA') to diagnose the causes of their differences in simulating ecosystem carbon storage capacity. Driven with similar forcing data, CLM-CASA' predicted – 31 % larger carbon storage capacity than CABLE. Since ecosystem carbon storage capacity is a product of net primary productivitymore » (NPP) and ecosystem residence time ( τ E), the predicted difference in the storage capacity between the two models results from differences in either NPP or τ E or both. Our analysis showed that CLM-CASA'simulated 37 % higher NPP than CABLE. On the other hand, τ E, which was a function of the baseline carbon residence time ( τ' E) and environmental effect on carbon residence time, was on average 11 years longer in CABLE than CLM-CASA'. This difference in τ E was mainly caused by longer τ' E of woody biomass (23 vs. 14 years in CLM-CASA'), and higher proportion of NPP allocated to woody biomass (23 vs. 16 %). Differences in environmental effects on carbon residence times had smaller influences on differences in ecosystem carbon storage capacities compared to differences in NPP and τ' E. Altogether, the traceability analysis showed that the major causes of different carbon storage estimations were found to be parameters setting related to carbon input and baseline carbon residence times between two models.« less

  15. Traceable quantum sensing and metrology relied up a quantum electrical triangle principle

    NASA Astrophysics Data System (ADS)

    Fang, Yan; Wang, Hengliang; Yang, Xinju; Wei, Jingsong

    2016-11-01

    Hybrid quantum state engineering in quantum communication and imaging1-2 needs traceable quantum sensing and metrology, which are especially critical to quantum internet3 and precision measurements4 that are important across all fields of science and technology-. We aim to set up a mode of traceable quantum sensing and metrology. We developed a method by specially transforming an atomic force microscopy (AFM) and a scanning tunneling microscopy (STM) into a conducting atomic force microscopy (C-AFM) with a feedback control loop, wherein quantum entanglement enabling higher precision was relied upon a set-point, a visible light laser beam-controlled an interferometer with a surface standard at z axis, diffractometers with lateral standards at x-y axes, four-quadrant photodiode detectors, a scanner and its image software, a phase-locked pre-amplifier, a cantilever with a kHz Pt/Au conducting tip, a double barrier tunneling junction model, a STM circuit by frequency modulation and a quantum electrical triangle principle involving single electron tunneling effect, quantum Hall effect and Josephson effect5. The average and standard deviation result of repeated measurements on a 1 nm height local micro-region of nanomedicine crystal hybrid quantum state engineering surface and its differential pA level current and voltage (dI/dV) in time domains by using C-AFM was converted into an international system of units: Siemens (S), an indicated value 0.86×10-12 S (n=6) of a relative standard uncertainty was superior over a relative standard uncertainty reference value 2.3×10-10 S of 2012 CODADA quantized conductance6. It is concluded that traceable quantum sensing and metrology is emerging.

  16. 3D printing of microtube in solid phantom to simulate tissue oxygenation and perfusion (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Lv, Xiang; Xue, Yue; Wang, Haili; Shen, Shu Wei; Zhou, Ximing; Liu, Guangli; Dong, Erbao; Xu, Ronald X.

    2017-03-01

    Tissue-simulating phantoms with interior vascular network may facilitate traceable calibration and quantitative validation of many medical optical devices. However, a solid phantom that reliably simulates tissue oxygenation and blood perfusion is still not available. This paper presents a new method to fabricate hollow microtubes for blood vessel simulation in solid phantoms. The fabrication process combines ultraviolet (UV) rapid prototyping technique with fluid mechanics of a coaxial jet flow. Polydimethylsiloxane (PDMS) and a UV-curable polymer are mixed at the designated ratio and extruded through a coaxial needle device to produce a coaxial jet flow. The extruded jet flow is quickly photo-polymerized by ultraviolet (UV) light to form vessel-simulating solid structures at different sizes ranging from 700 μm to 1000 μm. Microtube structures with adequate mechanical properties can be fabricated by adjusting material compositions and illumination intensity. Curved, straight and stretched microtubes can be formed by adjusting the extrusion speed of the materials and the speed of the 3D printing platform. To simulate vascular structures in biologic tissue, we embed vessel-simulating microtubes in a gel wax phantom of 10 cm x10 cm x 5 cm at the depth from 1 to 2 mm. Bloods at different oxygenation and hemoglobin concentration levels are circulated through the microtubes at different flow rates in order to simulate different oxygenation and perfusion conditions. The simulated physiologic parameters are detected by a tissue oximeter and a laser speckle blood flow meter respectively and compared with the actual values. Our experiments demonstrate that the proposed 3D printing process is able to produce solid phantoms with simulated vascular networks for potential applications in medical device calibration and drug delivery studies.

  17. Reacting Multi-Species Gas Capability for USM3D Flow Solver

    NASA Technical Reports Server (NTRS)

    Frink, Neal T.; Schuster, David M.

    2012-01-01

    The USM3D Navier-Stokes flow solver contributed heavily to the NASA Constellation Project (CxP) as a highly productive computational tool for generating the aerodynamic databases for the Ares I and V launch vehicles and Orion launch abort vehicle (LAV). USM3D is currently limited to ideal-gas flows, which are not adequate for modeling the chemistry or temperature effects of hot-gas jet flows. This task was initiated to create an efficient implementation of multi-species gas and equilibrium chemistry into the USM3D code to improve its predictive capabilities for hot jet impingement effects. The goal of this NASA Engineering and Safety Center (NESC) assessment was to implement and validate a simulation capability to handle real-gas effects in the USM3D code. This document contains the outcome of the NESC assessment.

  18. Final Report Nucleic Acid System - Hybrid PCR and Multiplex Assay Project Phase 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koopman, R P; Langlois, R G; Nasarabadi, S

    2002-04-17

    This report covers phase 2 (year 2) of the Nucleic Acid System--Hybrid PCR and Multiplex Assay project. The objective of the project is to reduce to practice the detection and identification of biological warfare pathogens by the nucleic acid recognition technique of PCR (polymerase chain reaction) in a multiplex mode using flow cytometry. The Hybrid instrument consists of a flow-through PCR module capable of handling a multiplexed PCR assay, a hybridizing module capable of hybridizing multiplexed PCR amplicons and beads, and a flow cytometer module for bead-based identification, all controlled by a single computer. Multiplex immunoassay using bead-based Luminex flowmore » cytometry is available, allowing rapid screening for many agents. PCR is highly specific and complements and verifies immunoassay. It can also be multiplexed and detection provided using the bead-based Luminex flow cytometer. This approach allows full access to the speed and 100-fold multiplex capability of flow cytometry for rapid screening as well as the accuracy and specificity of PCR. This project has two principal activities: (1) Design, build and test a prototype hybrid PCR/flow cytometer with the basic capabilities for rapid, broad spectrum detection and identification, and (2) Develop and evaluate multiplex flow analysis assay protocols and reagents for the simultaneous detection of PCR products. This project requires not only building operationally functional instrumentation but also developing the chemical assays for detection of priority pathogens. This involves development and evaluation of multiplex flow analysis assay protocols and reagents for the simultaneous detection of PCR products.« less

  19. Centrifugal and Axial Pump Design and Off-Design Performance Prediction

    NASA Technical Reports Server (NTRS)

    Veres, Joseph P.

    1995-01-01

    A meanline pump-flow modeling method has been developed to provide a fast capability for modeling pumps of cryogenic rocket engines. Based on this method, a meanline pump-flow code PUMPA was written that can predict the performance of pumps at off-design operating conditions, given the loss of the diffusion system at the design point. The design-point rotor efficiency and slip factors are obtained from empirical correlations to rotor-specific speed and geometry. The pump code can model axial, inducer, mixed-flow, and centrifugal pumps and can model multistage pumps in series. The rapid input setup and computer run time for this meanline pump flow code make it an effective analysis and conceptual design tool. The map-generation capabilities of the code provide the information needed for interfacing with a rocket engine system modeling code. The off-design and multistage modeling capabilities of PUMPA permit the user to do parametric design space exploration of candidate pump configurations and to provide head-flow maps for engine system evaluation.

  20. SAFSIM theory manual: A computer program for the engineering simulation of flow systems

    NASA Astrophysics Data System (ADS)

    Dobranich, Dean

    1993-12-01

    SAFSIM (System Analysis Flow SIMulator) is a FORTRAN computer program for simulating the integrated performance of complex flow systems. SAFSIM provides sufficient versatility to allow the engineering simulation of almost any system, from a backyard sprinkler system to a clustered nuclear reactor propulsion system. In addition to versatility, speed and robustness are primary SAFSIM development goals. SAFSIM contains three basic physics modules: (1) a fluid mechanics module with flow network capability; (2) a structure heat transfer module with multiple convection and radiation exchange surface capability; and (3) a point reactor dynamics module with reactivity feedback and decay heat capability. Any or all of the physics modules can be implemented, as the problem dictates. SAFSIM can be used for compressible and incompressible, single-phase, multicomponent flow systems. Both the fluid mechanics and structure heat transfer modules employ a one-dimensional finite element modeling approach. This document contains a description of the theory incorporated in SAFSIM, including the governing equations, the numerical methods, and the overall system solution strategies.

  1. Supersonic Particle Impact Test Capabilities: Investigative Report

    NASA Technical Reports Server (NTRS)

    Rosales, Keisa

    2007-01-01

    NASA Johnson Space Center White Sands Test Facility (WSTF) performed particle impact flow tests to determine the maximum capabilities of the particle impact test systems in different configurations. Additional flow tests were performed to determine the target pressures at given upstream conditions to supplement the WSTF data located in ASTM Manual 36 (2000).

  2. 40 CFR 63.993 - Absorbers, condensers, carbon adsorbers and other recovery devices used as final recovery devices.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... providing a continuous record or an integrating regeneration stream flow monitoring device having an accuracy of ±10 percent or better, capable of recording the total regeneration stream mass or volumetric flow for each regeneration cycle; and a carbon-bed temperature monitoring device, capable of recording...

  3. 40 CFR 63.990 - Absorbers, condensers, and carbon adsorbers used as control devices.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... adsorber is used, an integrating regeneration stream flow monitoring device having an accuracy of ±10 percent or better, capable of recording the total regeneration stream mass or volumetric flow for each regeneration cycle; and a carbon bed temperature monitoring device, capable of recording the carbon bed...

  4. 40 CFR 63.990 - Absorbers, condensers, and carbon adsorbers used as control devices.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... adsorber is used, an integrating regeneration stream flow monitoring device having an accuracy of ±10 percent or better, capable of recording the total regeneration stream mass or volumetric flow for each regeneration cycle; and a carbon bed temperature monitoring device, capable of recording the carbon bed...

  5. 40 CFR 63.993 - Absorbers, condensers, carbon adsorbers and other recovery devices used as final recovery devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... providing a continuous record or an integrating regeneration stream flow monitoring device having an accuracy of ±10 percent or better, capable of recording the total regeneration stream mass or volumetric flow for each regeneration cycle; and a carbon-bed temperature monitoring device, capable of recording...

  6. 40 CFR 63.990 - Absorbers, condensers, and carbon adsorbers used as control devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... adsorber is used, an integrating regeneration stream flow monitoring device having an accuracy of ±10 percent or better, capable of recording the total regeneration stream mass or volumetric flow for each regeneration cycle; and a carbon bed temperature monitoring device, capable of recording the carbon bed...

  7. 40 CFR 63.993 - Absorbers, condensers, carbon adsorbers and other recovery devices used as final recovery devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... providing a continuous record or an integrating regeneration stream flow monitoring device having an accuracy of ±10 percent or better, capable of recording the total regeneration stream mass or volumetric flow for each regeneration cycle; and a carbon-bed temperature monitoring device, capable of recording...

  8. 40 CFR 63.993 - Absorbers, condensers, carbon adsorbers and other recovery devices used as final recovery devices.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... providing a continuous record or an integrating regeneration stream flow monitoring device having an accuracy of ±10 percent or better, capable of recording the total regeneration stream mass or volumetric flow for each regeneration cycle; and a carbon-bed temperature monitoring device, capable of recording...

  9. 40 CFR 63.990 - Absorbers, condensers, and carbon adsorbers used as control devices.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... adsorber is used, an integrating regeneration stream flow monitoring device having an accuracy of ±10 percent or better, capable of recording the total regeneration stream mass or volumetric flow for each regeneration cycle; and a carbon bed temperature monitoring device, capable of recording the carbon bed...

  10. 40 CFR 63.993 - Absorbers, condensers, carbon adsorbers and other recovery devices used as final recovery devices.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... providing a continuous record or an integrating regeneration stream flow monitoring device having an accuracy of ±10 percent or better, capable of recording the total regeneration stream mass or volumetric flow for each regeneration cycle; and a carbon-bed temperature monitoring device, capable of recording...

  11. 40 CFR 63.990 - Absorbers, condensers, and carbon adsorbers used as control devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... adsorber is used, an integrating regeneration stream flow monitoring device having an accuracy of ±10 percent or better, capable of recording the total regeneration stream mass or volumetric flow for each regeneration cycle; and a carbon bed temperature monitoring device, capable of recording the carbon bed...

  12. A hash based mutual RFID tag authentication protocol in telecare medicine information system.

    PubMed

    Srivastava, Keerti; Awasthi, Amit K; Kaul, Sonam D; Mittal, R C

    2015-01-01

    Radio Frequency Identification (RFID) is a technology which has multidimensional applications to reduce the complexity of today life. Everywhere, like access control, transportation, real-time inventory, asset management and automated payment systems etc., RFID has its enormous use. Recently, this technology is opening its wings in healthcare environments, where potential applications include patient monitoring, object traceability and drug administration systems etc. In this paper, we propose a secure RFID-based protocol for the medical sector. This protocol is based on hash operation with synchronized secret. The protocol is safe against active and passive attacks such as forgery, traceability, replay and de-synchronization attack.

  13. The Legitimate Name of a Fungal Plant Pathogen and the Ethics of Publication in the Era of Traceability.

    PubMed

    Gonthier, Paolo; Visentin, Ivan; Valentino, Danila; Tamietti, Giacomo; Cardinale, Francesca

    2017-04-01

    When more scientists describe independently the same species under different valid Latin names, a case of synonymy occurs. In such a case, the international nomenclature rules stipulate that the first name to appear on a peer-reviewed publication has priority over the others. Based on a recent episode involving priority determination between two competing names of the same fungal plant pathogen, this letter wishes to open a discussion on the ethics of scientific publications and points out the necessity of a correct management of the information provided through personal communications, whose traceability would prevent their fraudulent or accidental manipulation.

  14. Soft Fruit Traceability in Food Matrices using Real-Time PCR

    PubMed Central

    Palmieri, Luisa; Bozza, Elisa; Giongo, Lara

    2009-01-01

    Food product authentication provides a means of monitoring and identifying products for consumer protection and regulatory compliance. There is a scarcity of analytical methods for confirming the identity of fruit pulp in products containing Soft Fruit. In the present work we have developed a very sensible qualitative and quantitative method to determine the presence of berry DNAs in different food matrices. To our knowledge, this is the first study that shows the applicability, to Soft Fruit traceability, of melting curve analysis and multiplexed fluorescent probes, in a Real-Time PCR platform. This methodology aims to protect the consumer from label misrepresentation. PMID:22253987

  15. Traceability of Plant Diet Contents in Raw Cow Milk Samples

    PubMed Central

    Ponzoni, Elena; Mastromauro, Francesco; Gianì, Silvia; Breviario, Diego

    2009-01-01

    The use of molecular marker in the dairy sector is gaining large acceptance as a reliable diagnostic approach for food authenticity and traceability. Using a PCR approach, the rbcL marker, a chloroplast-based gene, was selected to amplify plant DNA fragments in raw cow milk samples collected from stock farms or bought on the Italian market. rbcL-specific DNA fragments could be found in total milk, as well as in the skimmed and the cream fractions. When the PCR amplified fragments were sent to sequence, the nucleotide composition of the chromatogram reflected the multiple contents of the polyphytic diet. PMID:22253982

  16. Comparison of the performance of the next generation of optical interferometers

    NASA Astrophysics Data System (ADS)

    Pisani, Marco; Yacoot, Andrew; Balling, Petr; Bancone, Nicola; Birlikseven, Cengiz; Çelik, Mehmet; Flügge, Jens; Hamid, Ramiz; Köchert, Paul; Kren, Petr; Kuetgens, Ulrich; Lassila, Antti; Bartolo Picotto, Gian; Şahin, Ersoy; Seppä, Jeremias; Tedaldi, Matthew; Weichert, Christoph

    2012-08-01

    Six European National Measurement Institutes (NMIs) have joined forces within the European Metrology Research Programme funded project NANOTRACE to develop the next generation of optical interferometers having a target uncertainty of 10 pm. These are needed for NMIs to provide improved traceable dimensional metrology that can be disseminated to the wider nanotechnology community, thereby supporting the growth in nanotechnology. Several approaches were followed in order to develop the interferometers. This paper briefly describes the different interferometers developed by the various partners and presents the results of a comparison of performance of the optical interferometers using an x-ray interferometer to generate traceable reference displacements.

  17. Traceability of Opuntia ficus-indica L. Miller by ICP-MS multi-element profile and chemometric approach.

    PubMed

    Mottese, Antonio Francesco; Naccari, Clara; Vadalà, Rossella; Bua, Giuseppe Daniel; Bartolomeo, Giovanni; Rando, Rossana; Cicero, Nicola; Dugo, Giacomo

    2018-01-01

    Opuntia ficus-indica L. Miller fruits, particularly 'Ficodindia dell'Etna' of Biancavilla (POD), 'Fico d'india tradizionale di Roccapalumba' with protected brand and samples from an experimental field in Pezzolo (Sicily) were analyzed by inductively coupled plasma mass spectrometry in order to determine the multi-element profile. A multivariate chemometric approach, specifically principal component analysis (PCA), was applied to individuate how mineral elements may represent a marker of geographic origin, which would be useful for traceability. PCA has allowed us to verify that the geographical origin of prickly pear fruits is significantly influenced by trace element content, and the results found in Biancavilla PDO samples were linked to the geological composition of this volcanic areas. It was observed that two principal components accounted for 72.03% of the total variance in the data and, in more detail, PC1 explains 45.51% and PC2 26.52%, respectively. This study demonstrated that PCA is an integrated tool for the traceability of food products and, at the same time, a useful method of authentication of typical local fruits such as prickly pear. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  18. Certified Reference Material for Use in 1H, 31P, and 19F Quantitative NMR, Ensuring Traceability to the International System of Units.

    PubMed

    Rigger, Romana; Rück, Alexander; Hellriegel, Christine; Sauermoser, Robert; Morf, Fabienne; Breitruck, KathrinBreitruck; Obkircher, Markus

    2017-09-01

    In recent years, quantitative NMR (qNMR) spectroscopy has become one of the most important tools for content determination of organic substances and quantitative evaluation of impurities. Using Certified Reference Materials (CRMs) as internal or external standards, the extensively used qNMR method can be applied for purity determination, including unbroken traceability to the International System of Units (SI). The implementation of qNMR toward new application fields, e.g., metabolomics, environmental analysis, and physiological pathway studies, brings along more complex molecules and systems, thus making use of 1H qNMR challenging. A smart workaround is possible by the use of other NMR active nuclei, namely 31P and 19F. This article presents the development of three classes of qNMR CRMs based on different NMR active nuclei (1H, 31P, and 19F), and the corresponding approaches to establish traceability to the SI through primary CRMs from the National Institute of Standards and Technology and the National Metrology Institute of Japan. These TraceCERT® qNMR CRMs are produced under ISO/IEC 17025 and ISO Guide 34 using high-performance qNMR.

  19. Force Sensor Characterization Under Sinusoidal Excitations

    PubMed Central

    Medina, Nieves; de Vicente, Jesús

    2014-01-01

    The aim in the current work is the development of a method to characterize force sensors under sinusoidal excitations using a primary standard as the source of traceability. During this work the influence factors have been studied and a method to minimise their contributions, as well as the corrections to be performed under dynamic conditions have been established. These results will allow the realization of an adequate characterization of force sensors under sinusoidal excitations, which will be essential for its further proper use under dynamic conditions. The traceability of the sensor characterization is based in the direct definition of force as mass multiplied by acceleration. To do so, the sensor is loaded with different calibrated loads and is maintained under different sinusoidal accelerations by means of a vibration shaker system that is able to generate accelerations up to 100 m/s2 with frequencies from 5 Hz up to 2400 Hz. The acceleration is measured by means of a laser vibrometer with traceability to the units of time and length. A multiple channel data acquisition system is also required to simultaneously acquire the electrical output signals of the involved instrument in real time. PMID:25290287

  20. Recent developments in application of stable isotope analysis on agro-product authenticity and traceability.

    PubMed

    Zhao, Yan; Zhang, Bin; Chen, Gang; Chen, Ailiang; Yang, Shuming; Ye, Zhihua

    2014-02-15

    With the globalisation of agro-product markets and convenient transportation of food across countries and continents, the potential for distribution of mis-labelled products increases accordingly, highlighting the need for measures to identify the origin of food. High quality food with identified geographic origin is a concern not only for consumers, but also for agriculture farmers, retailers and administrative authorities. Currently, stable isotope ratio analysis in combination with other chemical methods gradually becomes a promising approach for agro-product authenticity and traceability. In the last five years, a growing number of research papers have been published on tracing agro-products by stable isotope ratio analysis and techniques combining with other instruments. In these reports, the global variety of stable isotope compositions has been investigated, including light elements such as C, N, H, O and S, and heavy isotopes variation such as Sr and B. Several factors also have been considered, including the latitude, altitude, evaporation and climate conditions. In the present paper, an overview is provided on the authenticity and traceability of the agro-products from both animal and plant sources by stable isotope ratio analysis. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Metrological traceability of carbon dioxide measurements in atmosphere and seawater

    NASA Astrophysics Data System (ADS)

    Rolle, F.; Pessana, E.; Sega, M.

    2017-05-01

    The accurate determination of gaseous pollutants is fundamental for the monitoring of the trends of these analytes in the environment and the application of the metrological concepts to this field is necessary to assure the reliability of the measurement results. In this work, an overview of the activity carried out at Istituto Nazionale di Ricerca Metrologica to establish the metrological traceability of the measurements of gaseous atmospheric pollutants, in particular of carbon dioxide (CO2), is presented. Two primary methods, the gravimetry and the dynamic dilution, are used for the preparation of reference standards for composition which can be used to calibrate sensors and analytical instrumentation. At present, research is carried out to lower the measurement uncertainties of the primary gas mixtures and to extend their application to the oceanic field. The reason of such investigation is due to the evidence of the changes occurring in seawater carbonate chemistry, connected to the rising level of CO2 in the atmosphere. The well established activity to assure the metrological traceability of CO2 in the atmosphere will be applied to the determination of CO2 in seawater, by developing suitable reference materials for calibration and control of the sensors during their routine use.

  2. Chemometrics Methods for Specificity, Authenticity and Traceability Analysis of Olive Oils: Principles, Classifications and Applications.

    PubMed

    Messai, Habib; Farman, Muhammad; Sarraj-Laabidi, Abir; Hammami-Semmar, Asma; Semmar, Nabil

    2016-11-17

    Olive oils (OOs) show high chemical variability due to several factors of genetic, environmental and anthropic types. Genetic and environmental factors are responsible for natural compositions and polymorphic diversification resulting in different varietal patterns and phenotypes. Anthropic factors, however, are at the origin of different blends' preparation leading to normative, labelled or adulterated commercial products. Control of complex OO samples requires their (i) characterization by specific markers; (ii) authentication by fingerprint patterns; and (iii) monitoring by traceability analysis. These quality control and management aims require the use of several multivariate statistical tools: specificity highlighting requires ordination methods; authentication checking calls for classification and pattern recognition methods; traceability analysis implies the use of network-based approaches able to separate or extract mixed information and memorized signals from complex matrices. This chapter presents a review of different chemometrics methods applied for the control of OO variability from metabolic and physical-chemical measured characteristics. The different chemometrics methods are illustrated by different study cases on monovarietal and blended OO originated from different countries. Chemometrics tools offer multiple ways for quantitative evaluations and qualitative control of complex chemical variability of OO in relation to several intrinsic and extrinsic factors.

  3. Stem cell banking: between traceability and identifiability

    PubMed Central

    2010-01-01

    Stem cell banks are increasingly seen as an essential resource of biological materials for both basic and translational research. Stem cell banks support transnational access to quality-controlled and ethically sourced stem cell lines from different origins and of varying grades. According to the Organisation for Economic Co-operation and Development, advances in regenerative medicine are leading to the development of a bioeconomy, 'a world where biotechnology contributes to a significant share of economic output'. Consequently, stem cell banks are destined to constitute a pillar of the bioeconomy in many countries. While certain ethical and legal concerns are specific to the nature of stem cells, stem cell banking could do well to examine the approaches fostered by tissue banking generally. Indeed, the past decade has seen a move to simplify and harmonize biological tissue and data banking so as to foster international interoperability. In particular, the issues of consent and of traceability illustrate not only commonalities but the opportunity for stem cell banking to appreciate the lessons learned in biobanking generally. This paper analyzes convergence and divergence in issues surrounding policy harmonization, transnational sharing, informed consent, traceability and return of results in the context of stem cell banks. PMID:20923580

  4. A new, high-precision measurement of the X-ray Cu K α spectrum

    NASA Astrophysics Data System (ADS)

    Mendenhall, Marcus H.; Cline, James P.; Henins, Albert; Hudson, Lawrence T.; Szabo, Csilla I.; Windover, Donald

    2016-03-01

    One of the primary measurement issues addressed with NIST Standard Reference Materials (SRMs) for powder diffraction is that of line position. SRMs for this purpose are certified with respect to lattice parameter, traceable to the SI through precise measurement of the emission spectrum of the X-ray source. Therefore, accurate characterization of the emission spectrum is critical to a minimization of the error bounds on the certified parameters. The presently accepted sources for the SI traceable characterization of the Cu K α emission spectrum are those of Härtwig, Hölzer et al., published in the 1990s. The structure of the X-ray emission lines of the Cu K α complex has been remeasured on a newly commissioned double-crystal instrument, with six-bounce Si (440) optics, in a manner directly traceable to the SI definition of the meter. In this measurement, the entire region from 8020 eV to 8100 eV has been covered with a highly precise angular scale and well-defined system efficiency, providing accurate wavelengths and relative intensities. This measurement is in modest disagreement with reference values for the wavelength of the Kα1 line, and strong disagreement for the wavelength of the Kα2 line.

  5. [Traceability of Wine Varieties Using Near Infrared Spectroscopy Combined with Cyclic Voltammetry].

    PubMed

    Li, Meng-hua; Li, Jing-ming; Li, Jun-hui; Zhang, Lu-da; Zhao, Long-lian

    2015-06-01

    To achieve the traceability of wine varieties, a method was proposed to fuse Near-infrared (NIR) spectra and cyclic voltammograms (CV) which contain different information using D-S evidence theory. NIR spectra and CV curves of three different varieties of wines (cabernet sauvignon, merlot, cabernet gernischt) which come from seven different geographical origins were collected separately. The discriminant models were built using PLS-DA method. Based on this, D-S evidence theory was then applied to achieve the integration of the two kinds of discrimination results. After integrated by D-S evidence theory, the accuracy rate of cross-validation is 95.69% and validation set is 94.12% for wine variety identification. When only considering the wine that come from Yantai, the accuracy rate of cross-validation is 99.46% and validation set is 100%. All the traceability models after fusion achieved better results on classification than individual method. These results suggest that the proposed method combining electrochemical information with spectral information using the D-S evidence combination formula is benefit to the improvement of model discrimination effect, and is a promising tool for discriminating different kinds of wines.

  6. Identifying and Tracing User Needs

    NASA Astrophysics Data System (ADS)

    To, C.; Tauer, E.

    2017-12-01

    Providing adequate tools to the user community hinges on reaching the specific goals and needs behind the intended application of the tool. While the approach of leveraging user-supplied inputs and use cases to identify those goals is not new, there frequently remains the challenge of tracing those use cases through to implementation in an efficient and manageable fashion. Processes can become overcomplicated very quickly, and additionally, explicitly mapping progress towards the achievement of the user demands can become overwhelming when hundreds of use-cases are at play. This presentation will discuss a demonstrated use-case approach that has achieved an initial success with a tool re-design and deployment, the means to apply use cases in the generation of a roadmap for future releases over time, and the ability to include and adjust to new user requirements and suggestions with minimal disruption to the traceability. It is hoped that the findings and lessons learned will help make use case employment easier for others seeking to create user-targeted capabilities.

  7. Laser source for dimensional metrology: investigation of an iodine stabilized system based on narrow linewidth 633 nm DBR diode

    NASA Astrophysics Data System (ADS)

    Rerucha, Simon; Yacoot, Andrew; Pham, Tuan M.; Cizek, Martin; Hucl, Vaclav; Lazar, Josef; Cip, Ondrej

    2017-04-01

    We demonstrated that an iodine stabilized distributed Bragg reflector (DBR) diode based laser system lasing at a wavelength in close proximity to λ =633 nm could be used as an alternative laser source to the helium-neon lasers in both scientific and industrial metrology. This yields additional advantages besides the optical frequency stability and coherence: inherent traceability, wider optical frequency tuning range, higher output power and high frequency modulation capability. We experimentally investigated the characteristics of the laser source in two major steps: first using a wavelength meter referenced to a frequency comb controlled with a hydrogen maser and then on an interferometric optical bench testbed where we compared the performance of the laser system with that of a traditional frequency stabilized He-Ne laser. The results indicate that DBR diode laser system provides a good laser source for applications in dimensional (nano)metrology, especially in conjunction with novel interferometric detection methods exploiting high frequency modulation or multiaxis measurement systems.

  8. Roadmap to the Future

    NASA Astrophysics Data System (ADS)

    Colby, Eric R.; Len, L. K.

    Most particle accelerators today are expensive devices found only in the largest laboratories, industries, and hospitals. Using techniques developed nearly a century ago, the limiting performance of these accelerators is often traceable to material limitations, power source capabilities, and the cost tolerance of the application. Advanced accelerator concepts aim to increase the gradient of accelerators by orders of magnitude, using new power sources (e.g. lasers and relativistic beams) and new materials (e.g. dielectrics, metamaterials, and plasmas). Worldwide, research in this area has grown steadily in intensity since the 1980s, resulting in demonstrations of accelerating gradients that are orders of magnitude higher than for conventional techniques. While research is still in the early stages, these techniques have begun to demonstrate the potential to radically change accelerators, making them much more compact, and extending the reach of these tools of science into the angstrom and attosecond realms. Maturation of these techniques into robust, engineered devices will require sustained interdisciplinary, collaborative R&D and coherent use of test infrastructure worldwide. The outcome can potentially transform how accelerators are used.

  9. Roadmap to the Future

    NASA Astrophysics Data System (ADS)

    Colby, Eric R.; Len, L. K.

    Most particle accelerators today are expensive devices found only in the largest laboratories, industries, and hospitals. Using techniques developed nearly a century ago, the limiting performance of these accelerators is often traceable to material limitations, power source capabilities, and the cost tolerance of the application. Advanced accelerator conceptsa aim to increase the gradient of accelerators by orders of magnitude, using new power sources (e.g. lasers and relativistic beams) and new materials (e.g. dielectrics, metamaterials, and plasmas). Worldwide, research in this area has grown steadily in intensity since the 1980s, resulting in demonstrations of accelerating gradients that are orders of magnitude higher than for conventional techniques. While research is still in the early stages, these techniques have begun to demonstrate the potential to radically change accelerators, making them much more compact, and extending the reach of these tools of science into the angstrom and attosecond realms. Maturation of these techniques into robust, engineered devices will require sustained interdisciplinary, collaborative R&D and coherent use of test infrastructure worldwide. The outcome can potentially transform how accelerators are used.

  10. Spaceflight Flow Cytometry: Design Challenges and Applications

    NASA Technical Reports Server (NTRS)

    Pappas, Dimitri; Kao, Shih-Hsin; Jeevarajan, Antony S.

    2004-01-01

    Future space exploration missions will require analytical technology capable of providing both autonomous medical care to the crew and investigative capabilities to researchers. While several promising candidate technologies exist for further development, flow cytometry is an attractive technology as it offers both crew health and a wide array of biochemistry and immunology assays. While flow cytometry has been widely used for cellular analysis in both clinical and research settings, the requirements for proper operation in spaceflight impose constraints on any instrument designs. The challenges of designing a spaceflight-ready flow cytometer are discussed, as well as some preliminary results using a prototype system.

  11. Hypersonic flow analysis

    NASA Technical Reports Server (NTRS)

    Chow, Chuen-Yen; Ryan, James S.

    1987-01-01

    While the zonal grid system of Transonic Navier-Stokes (TNS) provides excellent modeling of complex geometries, improved shock capturing, and a higher Mach number range will be required if flows about hypersonic aircraft are to be modeled accurately. A computational fluid dynamics (CFD) code, the Compressible Navier-Stokes (CNS), is under development to combine the required high Mach number capability with the existing TNS geometry capability. One of several candidate flow solvers for inclusion in the CNS is that of F3D. This upwinding flow solver promises improved shock capturing, and more accurate hypersonic solutions overall, compared to the solver currently used in TNS.

  12. Lagrangian turbulence near walls: Structures and mixing in admissible model flows

    NASA Astrophysics Data System (ADS)

    Ottino, J. M.

    1989-05-01

    The general objective of work during this period was to bridge the gap between modern ideas from dynamical systems and chaos and more traditional approaches to turbulence. In order to reach this objective we conducted theoretical and computational work on two systems: a perturbed Kelvin cat eyes flow, and prototype solutions of the Navier-Stokes equations near solid walls. The main results obtained are two-fold: production flows capable of producing complex distributions of vorticity, and constructed flow fields, based on solutions of the Navier Stokes equations, which are capable of displaying both Eulerian and Lagrangian turbulence.

  13. Modeling mechanical restriction differences between car and heavy truck in two-lane cellular automata traffic flow model

    NASA Astrophysics Data System (ADS)

    Li, Xin; Li, Xingang; Xiao, Yao; Jia, Bin

    2016-06-01

    Real traffic is heterogeneous with car and truck. Due to mechanical restrictions, the car and the truck have different limited deceleration capabilities, which are important factors in safety driving. This paper extends the single lane safety driving (SD) model with limited deceleration capability to two-lane SD model, in which car-truck heterogeneous traffic is considered. A car has a larger limited deceleration capability while a heavy truck has a smaller limited deceleration capability as a result of loaded goods. Then the safety driving conditions are different as the types of the following and the leading vehicles vary. In order to eliminate the well-known plug in heterogeneous two-lane traffic, it is assumed that heavy truck has active deceleration behavior when the heavy truck perceives the forming plug. The lane-changing decisions are also determined by the safety driving conditions. The fundamental diagram, spatiotemporal diagram, and lane-changing frequency were investigated to show the effect of mechanical restriction on heterogeneous traffic flow. It was shown that there would be still three traffic phases in heterogeneous traffic condition; the active deceleration of the heavy truck could well eliminate the plug; the lane-changing frequency was low in synchronized flow; the flow and velocity would decrease as the proportion of heavy truck grows or the limited deceleration capability of heavy truck drops; and the flow could be improved with lane control measures.

  14. VS2DRTI: Simulating Heat and Reactive Solute Transport in Variably Saturated Porous Media.

    PubMed

    Healy, Richard W; Haile, Sosina S; Parkhurst, David L; Charlton, Scott R

    2018-01-29

    Variably saturated groundwater flow, heat transport, and solute transport are important processes in environmental phenomena, such as the natural evolution of water chemistry of aquifers and streams, the storage of radioactive waste in a geologic repository, the contamination of water resources from acid-rock drainage, and the geologic sequestration of carbon dioxide. Up to now, our ability to simulate these processes simultaneously with fully coupled reactive transport models has been limited to complex and often difficult-to-use models. To address the need for a simple and easy-to-use model, the VS2DRTI software package has been developed for simulating water flow, heat transport, and reactive solute transport through variably saturated porous media. The underlying numerical model, VS2DRT, was created by coupling the flow and transport capabilities of the VS2DT and VS2DH models with the equilibrium and kinetic reaction capabilities of PhreeqcRM. Flow capabilities include two-dimensional, constant-density, variably saturated flow; transport capabilities include both heat and multicomponent solute transport; and the reaction capabilities are a complete implementation of geochemical reactions of PHREEQC. The graphical user interface includes a preprocessor for building simulations and a postprocessor for visual display of simulation results. To demonstrate the simulation of multiple processes, the model is applied to a hypothetical example of injection of heated waste water to an aquifer with temperature-dependent cation exchange. VS2DRTI is freely available public domain software. © 2018, National Ground Water Association.

  15. Advanced Capabilities for Wind Tunnel Testing in the 21st Century

    NASA Technical Reports Server (NTRS)

    Kegelman, Jerome T.; Danehy, Paul M.; Schwartz, Richard J.

    2010-01-01

    Wind tunnel testing methods and test technologies for the 21st century using advanced capabilities are presented. These capabilities are necessary to capture more accurate and high quality test results by eliminating the uncertainties in testing and to facilitate verification of computational tools for design. This paper discusses near term developments underway in ground testing capabilities, which will enhance the quality of information of both the test article and airstream flow details. Also discussed is a selection of new capability investments that have been made to accommodate such developments. Examples include advanced experimental methods for measuring the test gas itself; using efficient experiment methodologies, including quality assurance strategies within the test; and increasing test result information density by using extensive optical visualization together with computed flow field results. These points could be made for both major investments in existing tunnel capabilities or for entirely new capabilities.

  16. Rapid architecture alternative modeling (RAAM): A framework for capability-based analysis of system of systems architectures

    NASA Astrophysics Data System (ADS)

    Iacobucci, Joseph V.

    The research objective for this manuscript is to develop a Rapid Architecture Alternative Modeling (RAAM) methodology to enable traceable Pre-Milestone A decision making during the conceptual phase of design of a system of systems. Rather than following current trends that place an emphasis on adding more analysis which tends to increase the complexity of the decision making problem, RAAM improves on current methods by reducing both runtime and model creation complexity. RAAM draws upon principles from computer science, system architecting, and domain specific languages to enable the automatic generation and evaluation of architecture alternatives. For example, both mission dependent and mission independent metrics are considered. Mission dependent metrics are determined by the performance of systems accomplishing a task, such as Probability of Success. In contrast, mission independent metrics, such as acquisition cost, are solely determined and influenced by the other systems in the portfolio. RAAM also leverages advances in parallel computing to significantly reduce runtime by defining executable models that are readily amendable to parallelization. This allows the use of cloud computing infrastructures such as Amazon's Elastic Compute Cloud and the PASTEC cluster operated by the Georgia Institute of Technology Research Institute (GTRI). Also, the amount of data that can be generated when fully exploring the design space can quickly exceed the typical capacity of computational resources at the analyst's disposal. To counter this, specific algorithms and techniques are employed. Streaming algorithms and recursive architecture alternative evaluation algorithms are used that reduce computer memory requirements. Lastly, a domain specific language is created to provide a reduction in the computational time of executing the system of systems models. A domain specific language is a small, usually declarative language that offers expressive power focused on a particular problem domain by establishing an effective means to communicate the semantics from the RAAM framework. These techniques make it possible to include diverse multi-metric models within the RAAM framework in addition to system and operational level trades. A canonical example was used to explore the uses of the methodology. The canonical example contains all of the features of a full system of systems architecture analysis study but uses fewer tasks and systems. Using RAAM with the canonical example it was possible to consider both system and operational level trades in the same analysis. Once the methodology had been tested with the canonical example, a Suppression of Enemy Air Defenses (SEAD) capability model was developed. Due to the sensitive nature of analyses on that subject, notional data was developed. The notional data has similar trends and properties to realistic Suppression of Enemy Air Defenses data. RAAM was shown to be traceable and provided a mechanism for a unified treatment of a variety of metrics. The SEAD capability model demonstrated lower computer runtimes and reduced model creation complexity as compared to methods currently in use. To determine the usefulness of the implementation of the methodology on current computing hardware, RAAM was tested with system of system architecture studies of different sizes. This was necessary since system of systems may be called upon to accomplish thousands of tasks. It has been clearly demonstrated that RAAM is able to enumerate and evaluate the types of large, complex design spaces usually encountered in capability based design, oftentimes providing the ability to efficiently search the entire decision space. The core algorithms for generation and evaluation of alternatives scale linearly with expected problem sizes. The SEAD capability model outputs prompted the discovery a new issue, the data storage and manipulation requirements for an analysis. Two strategies were developed to counter large data sizes, the use of portfolio views and top 'n' analysis. This proved the usefulness of the RAAM framework and methodology during Pre-Milestone A capability based analysis. (Abstract shortened by UMI.).

  17. Simulator for concurrent processing data flow architectures

    NASA Technical Reports Server (NTRS)

    Malekpour, Mahyar R.; Stoughton, John W.; Mielke, Roland R.

    1992-01-01

    A software simulator capability of simulating execution of an algorithm graph on a given system under the Algorithm to Architecture Mapping Model (ATAMM) rules is presented. ATAMM is capable of modeling the execution of large-grained algorithms on distributed data flow architectures. Investigating the behavior and determining the performance of an ATAMM based system requires the aid of software tools. The ATAMM Simulator presented is capable of determining the performance of a system without having to build a hardware prototype. Case studies are performed on four algorithms to demonstrate the capabilities of the ATAMM Simulator. Simulated results are shown to be comparable to the experimental results of the Advanced Development Model System.

  18. MODFLOW 2.0: A program for predicting moderator flow patterns

    NASA Astrophysics Data System (ADS)

    Peterson, P. F.; Paik, I. K.

    1991-07-01

    Sudden changes in the temperature of flowing liquids can result in transient buoyancy forces which strongly impact the flow hydrodynamics via flow stratification. These effects have been studied for the case of potential flow of stratified liquids to line sinks, but not for moderator flow in SRS reactors. Standard codes, such as TRAC and COMMIX, do not have the capability to capture the stratification effect, due to strong numerical diffusion which smears away the hot/cold fluid interface. A related problem with standard codes is the inability to track plumes injected into the liquid flow, again due to numerical diffusion. The combined effects of buoyant stratification and plume dispersion have been identified as being important in the operation of the Supplementary Safety System which injects neutron-poison ink into SRS reactors to provide safe shutdown in the event of safety rod failure. The MODFLOW code discussed here provides transient moderator flow pattern information with stratification effects, and tracks the location of ink plumes in the reactor. The code, written in Fortran, is compiled for Macintosh II computers, and includes subroutines for interactive control and graphical output. Removing the graphics capabilities, the code can also be compiled on other computers. With graphics, in addition to the capability to perform safety related computations, MODFLOW also provides an easy tool for becoming familiar with flow distributions in SRS reactors.

  19. The Use of UML for Software Requirements Expression and Management

    NASA Technical Reports Server (NTRS)

    Murray, Alex; Clark, Ken

    2015-01-01

    It is common practice to write English-language "shall" statements to embody detailed software requirements in aerospace software applications. This paper explores the use of the UML language as a replacement for the English language for this purpose. Among the advantages offered by the Unified Modeling Language (UML) is a high degree of clarity and precision in the expression of domain concepts as well as architecture and design. Can this quality of UML be exploited for the definition of software requirements? While expressing logical behavior, interface characteristics, timeliness constraints, and other constraints on software using UML is commonly done and relatively straight-forward, achieving the additional aspects of the expression and management of software requirements that stakeholders expect, especially traceability, is far less so. These other characteristics, concerned with auditing and quality control, include the ability to trace a requirement to a parent requirement (which may well be an English "shall" statement), to trace a requirement to verification activities or scenarios which verify that requirement, and to trace a requirement to elements of the software design which implement that requirement. UML Use Cases, designed for capturing requirements, have not always been satisfactory. Some applications of them simply use the Use Case model element as a repository for English requirement statements. Other applications of Use Cases, in which Use Cases are incorporated into behavioral diagrams that successfully communicate the behaviors and constraints required of the software, do indeed take advantage of UML's clarity, but not in ways that support the traceability features mentioned above. Our approach uses the Stereotype construct of UML to precisely identify elements of UML constructs, especially behaviors such as State Machines and Activities, as requirements, and also to achieve the necessary mapping capabilities. We describe this approach in the context of a space-based software application currently under development at the Jet Propulsion Laboratory.

  20. Proposed Requirements-driven User-scenario Development Protocol for the Belmont Forum E-Infrastructure and Data Management Cooperative Research Agreement

    NASA Astrophysics Data System (ADS)

    Wee, B.; Car, N.; Percivall, G.; Allen, D.; Fitch, P. G.; Baumann, P.; Waldmann, H. C.

    2014-12-01

    The Belmont Forum E-Infrastructure and Data Management Cooperative Research Agreement (CRA) is designed to foster a global community to collaborate on e-infrastructure challenges. One of the deliverables is an implementation plan to address global data infrastructure interoperability challenges and align existing domestic and international capabilities. Work package three (WP3) of the CRA focuses on the harmonization of global data infrastructure for sharing environmental data. One of the subtasks under WP3 is the development of user scenarios that guide the development of applicable deliverables. This paper describes the proposed protocol for user scenario development. It enables the solicitation of user scenarios from a broad constituency, and exposes the mechanisms by which those solicitations are evaluated against requirements that map to the Belmont Challenge. The underlying principle of traceability forms the basis for a structured, requirements-driven approach resulting in work products amenable to trade-off analyses and objective prioritization. The protocol adopts the ISO Reference Model for Open Distributed Processing (RM-ODP) as a top level framework. User scenarios are developed within RM-ODP's "Enterprise Viewpoint". To harmonize with existing frameworks, the protocol utilizes the conceptual constructs of "scenarios", "use cases", "use case categories", and use case templates as adopted by recent GEOSS Architecture Implementation Project (AIP) deliverables and CSIRO's eReefs project. These constructs are encapsulated under the larger construct of "user scenarios". Once user scenarios are ranked by goodness-of-fit to the Belmont Challenge, secondary scoring metrics may be generated, like goodness-of-fit to FutureEarth science themes. The protocol also facilitates an assessment of the ease of implementing given user scenario using existing GEOSS AIP deliverables. In summary, the protocol results in a traceability graph that can be extended to coordinate across research programmes. If implemented using appropriate technologies and harmonized with existing ontologies, this approach enables queries, sensitivity analyses, and visualization of complex relationships.

  1. Application of Shark Skin Flow Control Techniques to Airflow

    NASA Astrophysics Data System (ADS)

    Morris, Jackson Alexander

    Due to millions of years of evolution, sharks have evolved to become quick and efficient ocean apex predators. Shark skin is made up of millions of microscopic scales, or denticles, that are approximately 0.2 mm in size. Scales located on the shark's body where separation control is paramount (such as behind the gills or the trailing edge of the pectoral fin) are capable of bristling. These scales are hypothesized to act as a flow control mechanism capable of being passively actuated by reversed flow. It is believed that shark scales are strategically sized to interact with the lower 5% of a boundary layer, where reversed flow occurs at the onset of boundary layer separation. Previous research has shown shark skin to be capable of controlling separation in water. This thesis aims to investigate the same passive flow control techniques in air. To investigate this phenomenon, several sets of microflaps were designed and manufactured with a 3D printer. The microflaps were designed in both 2D (rectangular) and 3D (mirroring shark scale geometry) variants. These microflaps were placed in a low-speed wind tunnel in the lower 5% of the boundary layer. Solid fences and a flat plate diffuser with suction were placed in the tunnel to create different separated flow regions. A hot film probe was used to measure velocity magnitude in the streamwise plane of the separated regions. The results showed that low-speed airflow is capable of bristling objects in the boundary layer. When placed in a region of reverse flow, the microflaps were passively actuated. Microflaps fluctuated between bristled and flat states in reverse flow regions located close to the reattachment zone.

  2. Mean Line Pump Flow Model in Rocket Engine System Simulation

    NASA Technical Reports Server (NTRS)

    Veres, Joseph P.; Lavelle, Thomas M.

    2000-01-01

    A mean line pump flow modeling method has been developed to provide a fast capability for modeling turbopumps of rocket engines. Based on this method, a mean line pump flow code PUMPA has been written that can predict the performance of pumps at off-design operating conditions, given the loss of the diffusion system at the design point. The pump code can model axial flow inducers, mixed-flow and centrifugal pumps. The code can model multistage pumps in series. The code features rapid input setup and computer run time, and is an effective analysis and conceptual design tool. The map generation capability of the code provides the map information needed for interfacing with a rocket engine system modeling code. The off-design and multistage modeling capabilities of the code permit parametric design space exploration of candidate pump configurations and provide pump performance data for engine system evaluation. The PUMPA code has been integrated with the Numerical Propulsion System Simulation (NPSS) code and an expander rocket engine system has been simulated. The mean line pump flow code runs as an integral part of the NPSS rocket engine system simulation and provides key pump performance information directly to the system model at all operating conditions.

  3. Real Traceable Signatures

    NASA Astrophysics Data System (ADS)

    Chow, Sherman S. M.

    Traceable signature scheme extends a group signature scheme with an enhanced anonymity management mechanism. The group manager can compute a tracing trapdoor which enables anyone to test if a signature is signed by a given misbehaving user, while the only way to do so for group signatures requires revealing the signer of all signatures. Nevertheless, it is not tracing in a strict sense. For all existing schemes, T tracing agents need to recollect all N' signatures ever produced and perform RN' “checks” for R revoked users. This involves a high volume of transfer and computations. Increasing T increases the degree of parallelism for tracing but also the probability of “missing” some signatures in case some of the agents are dishonest.

  4. Ag@4ATP-coated liposomes: SERS traceable delivery vehicles for living cells.

    PubMed

    Zhu, Dan; Wang, Zhuyuan; Zong, Shenfei; Chen, Hui; Wu, Xin; Pei, Yuwei; Chen, Peng; Ma, Xueqin; Cui, Yiping

    2014-07-21

    A liposome-Ag nanohybrid has been demonstrated as a SERS traceable intracellular drug nanocarrier. Liposomes have been introduced for their special qualities in drug delivery systems. In essence, 4-aminothiophenol (4ATP) tagged Ag nanoparticles (Ag@4ATP) were adsorbed onto the surfaces of liposomes via electrostatic interactions, in which 4ATP was used as a SERS reporter. In such a nanohybrid, the locations of the carrier can be tracked by SERS signals while those of the drugs can be monitored through their fluorescence, allowing the simultaneous investigation of the intracellular distribution of both the carriers and the drugs. Our experimental results suggest that the reported liposomal system has substantial potential for intracellular drug delivery.

  5. Towards traceable transient pressure metrology

    NASA Astrophysics Data System (ADS)

    Hanson, Edward; Olson, Douglas A.; Liu, Haijun; Ahmed, Zeeshan; Douglass, Kevin O.

    2018-04-01

    We describe our progress in developing the infrastructure for traceable transient measurements of pressure. Towards that end, we have built and characterized a dual diaphragm shock tube that allows us to achieve shock amplitude reproducibility of approximately 2.3% for shocks with Mach speeds ranging from 1.26-1.5. In this proof-of-concept study we use our shock tube to characterize the dynamic response of photonic sensors embedded in polydimethylsiloxane (PDMS), a material of choice for soft tissue phantoms. Our results indicate that the PDMS-embedded photonic sensors response to shock evolves over a tens to hundreds of microseconds time scale making it a useful system for studying transient pressures in soft tissue.

  6. Adoption of Requirements Engineering Practices in Malaysian Software Development Companies

    NASA Astrophysics Data System (ADS)

    Solemon, Badariah; Sahibuddin, Shamsul; Ghani, Abdul Azim Abd

    This paper presents exploratory survey results on Requirements Engineering (RE) practices of some software development companies in Malaysia. The survey attempted to identify patterns of RE practices the companies are implementing. Information required for the survey was obtained through a survey, mailed self-administered questionnaires distributed to project managers and software developers who are working at software development companies operated across the country. The results showed that the overall adoption of the RE practices in these companies is strong. However, the results also indicated that fewer companies in the survey have use appropriate CASE tools or software to support their RE process and practices, define traceability policies and maintain traceability manual in their projects.

  7. RELAP-7 Software Verification and Validation Plan - Requirements Traceability Matrix (RTM) Part 2: Code Assessment Strategy, Procedure, and RTM Update

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yoo, Jun Soo; Choi, Yong Joon; Smith, Curtis Lee

    2016-09-01

    This document addresses two subjects involved with the RELAP-7 Software Verification and Validation Plan (SVVP): (i) the principles and plan to assure the independence of RELAP-7 assessment through the code development process, and (ii) the work performed to establish the RELAP-7 assessment plan, i.e., the assessment strategy, literature review, and identification of RELAP-7 requirements. Then, the Requirements Traceability Matrices (RTMs) proposed in previous document (INL-EXT-15-36684) are updated. These RTMs provide an efficient way to evaluate the RELAP-7 development status as well as the maturity of RELAP-7 assessment through the development process.

  8. Consumer Choice between Food Safety and Food Quality: The Case of Farm-Raised Atlantic Salmon

    PubMed Central

    Haghiri, Morteza

    2016-01-01

    Since the food incidence of polychlorinated biphenyls in farm-raised Atlantic salmon, its market demand has drastically changed as a result of consumers mistrust in both the quality and safety of the product. Policymakers have been trying to find ways to ensure consumers that farm-raised Atlantic salmon is safe. One of the suggested policies is the implementation of integrated traceability methods and quality control systems. This article examines consumer choice between food safety and food quality to purchase certified farm-raised Atlantic salmon, defined as a product that has passed through various stages of traceability systems in the province of Newfoundland and Labrador, Canada. PMID:28231118

  9. The flow patterning capability of localized natural convection.

    PubMed

    Huang, Ling-Ting; Chao, Ling

    2016-09-14

    Controlling flow patterns to align materials can have various applications in optics, electronics, and biosciences. In this study, we developed a natural-convection-based method to create desirable spatial flow patterns by controlling the locations of heat sources. Fluid motion in natural convection is induced by the spatial fluid density gradient that is caused by the established spatial temperature gradient. To analyze the patterning resolution capability of this method, we used a mathematical model combined with nondimensionalization to correlate the flow patterning resolution with experimental operating conditions. The nondimensionalized model suggests that the flow pattern and resolution is only influenced by two dimensionless parameters, and , where Gr is the Grashof number, representing the ratio of buoyancy to the viscous force acting on a fluid, and Pr is the Prandtl number, representing the ratio of momentum diffusivity to thermal diffusivity. We used the model to examine all of the flow behaviors in a wide range of the two dimensionless parameter group and proposed a flow pattern state diagram which suggests a suitable range of operating conditions for flow patterning. In addition, we developed a heating wire with an angular configuration, which enabled us to efficiently examine the pattern resolution capability numerically and experimentally. Consistent resolutions were obtained between the experimental results and model predictions, suggesting that the state diagram and the identified operating range can be used for further application.

  10. Flow measurements in a water tunnel using a holocinematographic velocimeter

    NASA Technical Reports Server (NTRS)

    Weinstein, Leonard M.; Beeler, George B.

    1987-01-01

    Dual-view holographic movies were used to examine complex flows with full three-space and time resolution. This approach, which tracks the movement of small tracer particles in water, is termed holocinematographic velocimetry (HCV). A small prototype of a new water tunnel was used to demonstrate proof-of-concept for the HCV. After utilizing a conventional flow visualization apparatus with a laser light sheet to illuminate tracer particles to evaluate flow quality of the prototype tunnel, a simplified version of the HCV was employed to demonstrate the capabilities of the approach. Results indicate that a full-scale version of the water tunnel and a high performance version of the HCV should be able to check theoretical and numerical modeling of complex flows and examine the mechanisms operative in turbulent and vortex flow control concepts, providing an entirely unique instrument capable, for the first time, of simultaneous three-space and time measurements in turbulent flow.

  11. Development of an Actuator for Flow Control Utilizing Detonation

    NASA Technical Reports Server (NTRS)

    Lonneman, Patrick J.; Cutler, Andrew D.

    2004-01-01

    Active flow control devices including mass injection systems and zero-net-mass flux actuators (synthetic jets) have been employed to delay flow separation. These devices are capable of interacting with low-speed, subsonic flows, but situations exist where a stronger crossflow interaction is needed. Small actuators that utilize detonation of premixed fuel and oxidizer should be capable of producing supersonic exit jet velocities. An actuator producing exit velocities of this magnitude should provide a more significant interaction with transonic and supersonic crossflows. This concept would be applicable to airfoils on high-speed aircraft as well as inlet and diffuser flow control. The present work consists of the development of a detonation actuator capable of producing a detonation in a single shot (one cycle). Multiple actuator configurations, initial fill pressures, oxidizers, equivalence ratios, ignition energies, and the addition of a turbulence generating device were considered experimentally and computationally. It was found that increased initial fill pressures and the addition of a turbulence generator aided in the detonation process. The actuators successfully produced Chapman-Jouguet detonations and wave speeds on the order of 3000 m/s.

  12. Thermally induced oscillations in fluid flow

    NASA Technical Reports Server (NTRS)

    Zuber, N.

    1970-01-01

    Theoretical investigation distinguishes the various mechanisms responsible for oscillations of pressure, temperature, and flow velocity, derives a quantitative description of the most troublesome mechanisms, and develops a capability to predict the occurrence of unstable flow.

  13. Development and Validation of an Automated Simulation Capability in Support of Integrated Demand Management

    NASA Technical Reports Server (NTRS)

    Arneson, Heather; Evans, Antony D.; Li, Jinhua; Wei, Mei Yueh

    2017-01-01

    Integrated Demand Management (IDM) is a near- to mid-term NASA concept that proposes to address mismatches in air traffic system demand and capacity by using strategic flow management capabilities to pre-condition demand into the more tactical Time-Based Flow Management System (TBFM). This paper describes an automated simulation capability to support IDM concept development. The capability closely mimics existing human-in-the-loop (HITL) capabilities, while automating both the human components and collaboration between operational systems, and speeding up the real-time aircraft simulations. Such a capability allows for parametric studies to be carried out that can inform the HITL simulations, identifying breaking points and parameter values at which significant changes in system behavior occur. The paper describes the initial validation of the automated simulation capability against results from previous IDM HITL experiments, quantifying the differences. The simulator is then used to explore the performance of the IDM concept under the simple scenario of a capacity constrained airport under a wide range of wind conditions.

  14. Development of High-purity Certified Reference Materials for 17 Proteinogenic Amino Acids by Traceable Titration Methods.

    PubMed

    Kato, Megumi; Yamazaki, Taichi; Kato, Hisashi; Eyama, Sakae; Goto, Mari; Yoshioka, Mariko; Takatsu, Akiko

    2015-01-01

    To ensure the reliability of amino acid analyses, the National Metrology Institute of Japan of the National Institute of Advanced Industrial Science and Technology (NMIJ/AIST) has developed high-purity certified reference materials (CRMs) for 17 proteinogenic amino acids. These CRMs are intended for use as primary reference materials to enable the traceable quantification of amino acids. The purity of the present CRMs was determined based on two traceable methods: nonaqueous acidimetric titration and nitrogen determination by the Kjeldahl method. Since neither method could distinguish compounds with similar structures, such as amino acid-related impurities, impurities were thoroughly quantified by combining several HPLC methods, and subtracted from the obtained purity of each method. The property value of each amino acid was calculated as a weighted mean of the corrected purities by the two methods. The uncertainty of the property value was obtained by combining measurement uncertainties of the two methods, a difference between the two methods, the uncertainty from the contribution of impurities, and the uncertainty derived from inhomogeneity. The uncertainty derived from instability was considered to be negligible based on stability monitoring of some CRMs. The certified value of each amino acid, property value with uncertainty, was given for both with or without enantiomeric separation.

  15. Chemometrics Methods for Specificity, Authenticity and Traceability Analysis of Olive Oils: Principles, Classifications and Applications

    PubMed Central

    Messai, Habib; Farman, Muhammad; Sarraj-Laabidi, Abir; Hammami-Semmar, Asma; Semmar, Nabil

    2016-01-01

    Background. Olive oils (OOs) show high chemical variability due to several factors of genetic, environmental and anthropic types. Genetic and environmental factors are responsible for natural compositions and polymorphic diversification resulting in different varietal patterns and phenotypes. Anthropic factors, however, are at the origin of different blends’ preparation leading to normative, labelled or adulterated commercial products. Control of complex OO samples requires their (i) characterization by specific markers; (ii) authentication by fingerprint patterns; and (iii) monitoring by traceability analysis. Methods. These quality control and management aims require the use of several multivariate statistical tools: specificity highlighting requires ordination methods; authentication checking calls for classification and pattern recognition methods; traceability analysis implies the use of network-based approaches able to separate or extract mixed information and memorized signals from complex matrices. Results. This chapter presents a review of different chemometrics methods applied for the control of OO variability from metabolic and physical-chemical measured characteristics. The different chemometrics methods are illustrated by different study cases on monovarietal and blended OO originated from different countries. Conclusion. Chemometrics tools offer multiple ways for quantitative evaluations and qualitative control of complex chemical variability of OO in relation to several intrinsic and extrinsic factors. PMID:28231172

  16. Sulfur-based absolute quantification of proteins using isotope dilution inductively coupled plasma mass spectrometry

    NASA Astrophysics Data System (ADS)

    Lee, Hyun-Seok; Heun Kim, Sook; Jeong, Ji-Seon; Lee, Yong-Moon; Yim, Yong-Hyeon

    2015-10-01

    An element-based reductive approach provides an effective means of realizing International System of Units (SI) traceability for high-purity biological standards. Here, we develop an absolute protein quantification method using double isotope dilution (ID) inductively coupled plasma mass spectrometry (ICP-MS) combined with microwave-assisted acid digestion for the first time. We validated the method and applied it to certify the candidate protein certified reference material (CRM) of human growth hormone (hGH). The concentration of hGH was determined by analysing the total amount of sulfur in hGH. Next, the size-exclusion chromatography method was used with ICP-MS to characterize and quantify sulfur-containing impurities. By subtracting the contribution of sulfur-containing impurities from the total sulfur content in the hGH CRM, we obtained a SI-traceable certification value. The quantification result obtained with the present method based on sulfur analysis was in excellent agreement with the result determined via a well-established protein quantification method based on amino acid analysis using conventional acid hydrolysis combined with an ID liquid chromatography-tandem mass spectrometry. The element-based protein quantification method developed here can be generally used for SI-traceable absolute quantification of proteins, especially pure-protein standards.

  17. Development and evaluation of an intelligent traceability system for frozen tilapia fillet processing.

    PubMed

    Xiao, Xinqing; Fu, Zetian; Qi, Lin; Mira, Trebar; Zhang, Xiaoshuan

    2015-10-01

    The main export varieties in China are brand-name, high-quality bred aquatic products. Among them, tilapia has become the most important and fast-growing species since extensive consumer markets in North America and Europe have evolved as a result of commodity prices, year-round availability and quality of fresh and frozen products. As the largest tilapia farming country, China has over one-third of its tilapia production devoted to further processing and meeting foreign market demand. Using by tilapia fillet processing, this paper introduces the efforts for developing and evaluating ITS-TF: an intelligent traceability system integrated with statistical process control (SPC) and fault tree analysis (FTA). Observations, literature review and expert questionnaires were used for system requirement and knowledge acquisition; scenario simulation was applied to evaluate and validate ITS-TF performance. The results show that traceability requirement is evolved from a firefighting model to a proactive model for enhancing process management capacity for food safety; ITS-TF transforms itself as an intelligent system to provide functions on early warnings and process management by integrated SPC and FTA. The valuable suggestion that automatic data acquisition and communication technology should be integrated into ITS-TF was achieved for further system optimization, perfection and performance improvement. © 2014 Society of Chemical Industry.

  18. Traceable atomic force microscopy of high-quality solvent-free crystals of [6,6]-phenyl-C61-butyric acid methyl ester

    NASA Astrophysics Data System (ADS)

    Lazzerini, Giovanni Mattia; Paternò, Giuseppe Maria; Tregnago, Giulia; Treat, Neil; Stingelin, Natalie; Yacoot, Andrew; Cacialli, Franco

    2016-02-01

    We report high-resolution, traceable atomic force microscopy measurements of high-quality, solvent-free single crystals of [6,6]-phenyl-C61-butyric acid methyl ester (PCBM). These were grown by drop-casting PCBM solutions onto the spectrosil substrates and by removing the residual solvent in a vacuum. A home-built atomic force microscope featuring a plane mirror differential optical interferometer, fiber-fed from a frequency-stabilized laser (emitting at 632.8 nm), was used to measure the crystals' height. The optical interferometer together with the stabilized laser provides traceability (via the laser wavelength) of the vertical measurements made with the atomic force microscope. We find that the crystals can conform to the surface topography, thanks to their height being significantly smaller compared to their lateral dimensions (namely, heights between about 50 nm and 140 nm, for the crystals analysed, vs. several tens of microns lateral dimensions). The vast majority of the crystals are flat, but an isolated, non-flat crystal provides insights into the growth mechanism and allows identification of "molecular terraces" whose height corresponds to one of the lattice constants of the single PCBM crystal (1.4 nm) as measured with X-ray diffraction.

  19. Applying high-resolution melting (HRM) technology to olive oil and wine authenticity.

    PubMed

    Pereira, Leonor; Gomes, Sónia; Barrias, Sara; Fernandes, José Ramiro; Martins-Lopes, Paula

    2018-01-01

    Olive oil and wine production have a worldwide economic impact. Their market reliability is under great concern because of the increasing number of fraud and adulteration attempts. The need for a traceability system in all its extension is crucial particularly for the cases of olive oils and wines with certified labels, in which only a limited number of olives and grapevine varieties, respectively, are allowed in a restricted well-defined geographical area. Molecular markers have been vastly applied to the food sector, and in particular High-Resolution DNA Melting technology has been successfully applied for olive oil and wine authentication, as part of the traceability system. In this review, the applications of HRM and their usefulness for this sector considering, Safety, Security and Authenticity will be reviewed. A broad overview of the HRM technique will be presented, focusing on the aspects that are crucial for its success, in particular the new generation of fluorescent dsDNA dyes used for amplicon detection and quantification, and the data analysis. A brief outlook on the olive oil and wine authenticity procedures, based on new DNA technology advances, and in which way this may influence the future establishment of a traceability system will be discussed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. ALT-114 and ALT-118 Alternative Approaches to NIST ...

    EPA Pesticide Factsheets

    In 2016, US EPA approved two separate alternatives (ALT 114 and ALT 118) for the preparation and certification of Hydrogen Chloride (HCl) and Mercury (Hg) cylinder reference gas standards that can serve as EPA Protocol gases where EPA Protocol are required, but unavailable. The alternatives were necessary due to the unavailability of NIST reference materials (SRM, NTRM, CRM or RGM) or VSL reference materials (VSL PRM or VSL CRM), reference materials identified in EPA’s Green Book as necessary to establish the traceability of EPA protocol gases. ALT 114 and ALT 118 provides a pathway for gas vendors to prepare and certify traceable gas cylinder standards for use in certifying Hg and HCl CEMS. In this presentation, EPA will describe the mechanics and requirements of the performance-based approach, provide an update on the availability of these gas standards and also discuss the potential for producing and certifying gas standards for other compounds using this approach. This presentation discusses the importance of NIST-traceable reference gases relative to regulatory source compliance emissions monitoring. Specifically this presentation discusses 2 new approaches for making necessary reference gases available in the absence of NIST reference materials. Moreover, these approaches provide an alternative approach to rapidly make available new reference gases for additional HAPS regulatory compliance emissions measurement and monitoring.

  1. Traceable atomic force microscopy of high-quality solvent-free crystals of [6,6]-phenyl-C{sub 61}-butyric acid methyl ester

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lazzerini, Giovanni Mattia; Yacoot, Andrew; Paternò, Giuseppe Maria

    2016-02-01

    We report high-resolution, traceable atomic force microscopy measurements of high-quality, solvent-free single crystals of [6,6]-phenyl-C61-butyric acid methyl ester (PCBM). These were grown by drop-casting PCBM solutions onto the spectrosil substrates and by removing the residual solvent in a vacuum. A home-built atomic force microscope featuring a plane mirror differential optical interferometer, fiber-fed from a frequency-stabilized laser (emitting at 632.8 nm), was used to measure the crystals' height. The optical interferometer together with the stabilized laser provides traceability (via the laser wavelength) of the vertical measurements made with the atomic force microscope. We find that the crystals can conform to the surfacemore » topography, thanks to their height being significantly smaller compared to their lateral dimensions (namely, heights between about 50 nm and 140 nm, for the crystals analysed, vs. several tens of microns lateral dimensions). The vast majority of the crystals are flat, but an isolated, non-flat crystal provides insights into the growth mechanism and allows identification of “molecular terraces” whose height corresponds to one of the lattice constants of the single PCBM crystal (1.4 nm) as measured with X-ray diffraction.« less

  2. Detecting past changes of effective population size

    PubMed Central

    Nikolic, Natacha; Chevalet, Claude

    2014-01-01

    Understanding and predicting population abundance is a major challenge confronting scientists. Several genetic models have been developed using microsatellite markers to estimate the present and ancestral effective population sizes. However, to get an overview on the evolution of population requires that past fluctuation of population size be traceable. To address the question, we developed a new model estimating the past changes of effective population size from microsatellite by resolving coalescence theory and using approximate likelihoods in a Monte Carlo Markov Chain approach. The efficiency of the model and its sensitivity to gene flow and to assumptions on the mutational process were checked using simulated data and analysis. The model was found especially useful to provide evidence of transient changes of population size in the past. The times at which some past demographic events cannot be detected because they are too ancient and the risk that gene flow may suggest the false detection of a bottleneck are discussed considering the distribution of coalescence times. The method was applied on real data sets from several Atlantic salmon populations. The method called VarEff (Variation of Effective size) was implemented in the R package VarEff and is made available at https://qgsp.jouy.inra.fr and at http://cran.r-project.org/web/packages/VarEff. PMID:25067949

  3. Ares I-X Launch Vehicle Modal Test Overview

    NASA Technical Reports Server (NTRS)

    Buehrle, Ralph D.; Bartolotta, Paul A.; Templeton, Justin D.; Reaves, Mercedes C.; Horta, Lucas G.; Gaspar, James L.; Parks, Russell A.; Lazor, Daniel R.

    2010-01-01

    The first test flight of NASA's Ares I crew launch vehicle, called Ares I-X, is scheduled for launch in 2009. Ares IX will use a 4-segment reusable solid rocket booster from the Space Shuttle heritage with mass simulators for the 5th segment, upper stage, crew module and launch abort system. Flight test data will provide important information on ascent loads, vehicle control, separation, and first stage reentry dynamics. As part of hardware verification, a series of modal tests were designed to verify the dynamic finite element model (FEM) used in loads assessments and flight control evaluations. Based on flight control system studies, the critical modes were the first three free-free bending mode pairs. Since a test of the free-free vehicle is not practical within project constraints, modal tests for several configurations in the nominal integration flow were defined to calibrate the FEM. A traceability study by Aerospace Corporation was used to identify the critical modes for the tested configurations. Test configurations included two partial stacks and the full Ares I-X launch vehicle on the Mobile Launcher Platform. This paper provides an overview for companion papers in the Ares I-X Modal Test Session. The requirements flow down, pre-test analysis, constraints and overall test planning are described.

  4. Critical appraisal of apparently evidence-based written advertising in Pakistan.

    PubMed

    Rohra, Dileep Kumar; Bashir, Muhammad Umair; Khwaja, Ummey Aymen; Nazir, Muhammad Ressam

    2008-06-01

    The objective of the study was to critically assess references cited in support of claims in drug advertisements. Drug advertising brochures were collected from privately practicing General Practitioners from different parts of Karachi. Three blinded reviewers then categorized each reference in the brochure according to the sources viz: journals (both Medline indexed and non-indexed), medical reference books, web addresses, personal communications or testimonials, abstracts presented at symposia/conferences, WHO and National Health Guidelines, 'data on file' and 'others' (which included a diverse set of references). Each reviewer then assessed and analyzed the references further into 2 broad categories: traceable and non-traceable. Traceable references were appraised and, depending upon the claim with which the reference was attached, were classified into justifiable, inaccurate/false, exaggerated and ambiguous. We collected a total of 175 different brochures. Thirty-nine (22.3%) brochures did not cite any references and were not subjected to further analysis. The remaining 136 (77.7%) contained a total of 559 references. 305 (54.6%) of these references were from Medline-indexed journals; 67 (12.0%) were from non-indexed journals; 55 (9.8%) references quoted medical reference books; 27 (4.8%) references cited web addresses; 12 (2.1%) references were personal communications/testimonials; 11 (2.0%) references referred to abstracts presented at symposia/conferences; 12 (2.1%) references were from WHO and National Health Guidelines; 8 (1.4%) references were listed as 'data on file', while the remainder that could not be defined were classified as 'others' (13.1%). Out of a total of 559 references, 249 (44.5%) could not be traced. After critically analyzing the 310 traceable references, 197 (63.5%) were adjudged justifiable, 30 (9.7%) inaccurate/false, 79 (25.5%) exaggerated and 15 (4.8%) ambiguous. Results of this study show for the first time that the claims substantiated with references in the pharmaceutical advertisements in Pakistan are highly unreliable.

  5. Validation of Ammonia Diffusive and Active Samplers in a Controlled Atmosphere Test Facility Using Traceable Primary Standard Gas Mixtures

    NASA Astrophysics Data System (ADS)

    Martin, N. A.; Ferracci, V.; Cassidy, N.; Hook, J.; Battersby, R. M.; Tang, Y. S.; Stevens, A. C. M.; Jones, M. R.; Braban, C. F.; Gates, L.; Hangartner, M.; Sacco, P.; Pagani, D.; Hoffnagle, J.

    2016-12-01

    Intensive farming, the increased use of fertilizers, and certain industrial processes are believed to be responsible for increases in the amount fraction of ammonia (NH3) found in Europe. NH3 contributes to eutrophication and acidification of land and freshwater, leading to a loss of biodiversity, undesirable changes to the ecosystem, and to secondary particulate matter (PM) formation. Measurements of ambient ammonia over a wide geographical area, are principally carried out with low-cost diffusive samplers or by active sampling with denuders, with each technique delivering time-integrated values over the monitoring period. The goal of this work was to measure the NH3 diffusive sampling rates of five different designs of commercial diffusive samplers (FSM Radiello radial sampler, Gradko diffusion tube, Gradko DIFRAM-400, Passam ammonia sampler, and CEH ALPHA sampler), together with validation tests with a denuder sampler (CEH DELTA denuder). The would deliver validated improvements in the accuracy of ambient measurements of NH3 in the field through the establishment of metrological traceability using new stable ammonia Primary Standard Gas Mixtures (PSMs), developed by gravimetry at NPL. All devices were simultaneously exposed in a controlled atmosphere test facility (CATFAC) containing traceable amount fractions of ammonia applicable to a range of ambient monitoring conditions, with well-defined conditions of temperature, relative humidity and wind speed. Online continuous monitoring of the test atmospheres was carried out with a calibrated cavity ring-down spectrometer modified to account for cross interference by water. Exposed samplers were analysed by individual manufacturers for ammonium using traceable wet chemical techniques. The measured diffusive sampling rates were then applied to field measurements carried out at the Whim Bog experimental station in Scotland, where there is a facility in place for controlled releases of NH3 and also a background site.

  6. Phenolic Profiling for Traceability of Vanilla ×tahitensis

    PubMed Central

    Busconi, Matteo; Lucini, Luigi; Soffritti, Giovanna; Bernardi, Jamila; Bernardo, Letizia; Brunschwig, Christel; Lepers-Andrzejewski, Sandra; Raharivelomanana, Phila; Fernandez, Jose A.

    2017-01-01

    Vanilla is a flavoring recovered from the cured beans of the orchid genus Vanilla. Vanilla ×tahitensis is traditionally cultivated on the islands of French Polynesia, where vanilla vines were first introduced during the nineteenth century and, since the 1960s, have been introduced to other Pacific countries such as Papua New Guinea (PNG), cultivated and sold as “Tahitian vanilla,” although both sensory properties and aspect are different. From an economic point of view, it is important to ensure V. ×tahitensis traceability and to guarantee that the marketed product is part of the future protected designation of the origin “Tahitian vanilla” (PDO), currently in progress in French Polynesia. The application of metabolomics, allowing the detection and simultaneous analysis of hundreds or thousands of metabolites from different matrices, has recently gained high interest in food traceability. Here, metabolomics analysis of phenolic compounds profiles was successfully applied for the first time to V. ×tahitensis to deepen our knowledge of vanilla metabolome, focusing on phenolics compounds, for traceability purposes. Phenolics were screened through a quadrupole-time-of-flight mass spectrometer coupled to a UHPLC liquid chromatography system, and 260 different compounds were clearly evidenced and subjected to different statistical analysis in order to enable the discrimination of the samples based on their origin. Eighty-eight and twenty three compounds, with a prevalence of flavonoids, resulted to be highly discriminant through ANOVA and Orthogonal Projections to Latent Structures Discriminant Analysis (OPLS-DA) respectively. Volcano plot analysis and pairwise comparisons were carried out to determine those compounds, mainly responsible for the differences among samples as a consequence of either origin or cultivar. The samples from PNG were clearly different from the Tahitian samples that were further divided in two different groups based on the different phenolic patterns. Among the 260 compounds, metabolomics analysis enabled the detection of previously unreported phenolics in vanilla (such as flavonoids, lignans, stilbenes and other polyphenols). PMID:29075276

  7. Phenolic Profiling for Traceability of Vanilla ×tahitensis.

    PubMed

    Busconi, Matteo; Lucini, Luigi; Soffritti, Giovanna; Bernardi, Jamila; Bernardo, Letizia; Brunschwig, Christel; Lepers-Andrzejewski, Sandra; Raharivelomanana, Phila; Fernandez, Jose A

    2017-01-01

    Vanilla is a flavoring recovered from the cured beans of the orchid genus Vanilla . Vanilla × tahitensis is traditionally cultivated on the islands of French Polynesia, where vanilla vines were first introduced during the nineteenth century and, since the 1960s, have been introduced to other Pacific countries such as Papua New Guinea (PNG), cultivated and sold as "Tahitian vanilla," although both sensory properties and aspect are different. From an economic point of view, it is important to ensure V . × tahitensis traceability and to guarantee that the marketed product is part of the future protected designation of the origin "Tahitian vanilla" (PDO), currently in progress in French Polynesia. The application of metabolomics, allowing the detection and simultaneous analysis of hundreds or thousands of metabolites from different matrices, has recently gained high interest in food traceability. Here, metabolomics analysis of phenolic compounds profiles was successfully applied for the first time to V . × tahitensis to deepen our knowledge of vanilla metabolome, focusing on phenolics compounds, for traceability purposes. Phenolics were screened through a quadrupole-time-of-flight mass spectrometer coupled to a UHPLC liquid chromatography system, and 260 different compounds were clearly evidenced and subjected to different statistical analysis in order to enable the discrimination of the samples based on their origin. Eighty-eight and twenty three compounds, with a prevalence of flavonoids, resulted to be highly discriminant through ANOVA and Orthogonal Projections to Latent Structures Discriminant Analysis (OPLS-DA) respectively. Volcano plot analysis and pairwise comparisons were carried out to determine those compounds, mainly responsible for the differences among samples as a consequence of either origin or cultivar. The samples from PNG were clearly different from the Tahitian samples that were further divided in two different groups based on the different phenolic patterns. Among the 260 compounds, metabolomics analysis enabled the detection of previously unreported phenolics in vanilla (such as flavonoids, lignans, stilbenes and other polyphenols).

  8. CLARREO Cornerstone of the Earth Observing System: Measuring Decadal Change Through Accurate Emitted Infrared and Reflected Solar Spectra and Radio Occultation

    NASA Technical Reports Server (NTRS)

    Sandford, Stephen P.

    2010-01-01

    The Climate Absolute Radiance and Refractivity Observatory (CLARREO) is one of four Tier 1 missions recommended by the recent NRC Decadal Survey report on Earth Science and Applications from Space (NRC, 2007). The CLARREO mission addresses the need to provide accurate, broadly acknowledged climate records that are used to enable validated long-term climate projections that become the foundation for informed decisions on mitigation and adaptation policies that address the effects of climate change on society. The CLARREO mission accomplishes this critical objective through rigorous SI traceable decadal change observations that are sensitive to many of the key uncertainties in climate radiative forcings, responses, and feedbacks that in turn drive uncertainty in current climate model projections. These same uncertainties also lead to uncertainty in attribution of climate change to anthropogenic forcing. For the first time CLARREO will make highly accurate, global, SI-traceable decadal change observations sensitive to the most critical, but least understood, climate forcings, responses, and feedbacks. The CLARREO breakthrough is to achieve the required levels of accuracy and traceability to SI standards for a set of observations sensitive to a wide range of key decadal change variables. The required accuracy levels are determined so that climate trend signals can be detected against a background of naturally occurring variability. Climate system natural variability therefore determines what level of accuracy is overkill, and what level is critical to obtain. In this sense, the CLARREO mission requirements are considered optimal from a science value perspective. The accuracy for decadal change traceability to SI standards includes uncertainties associated with instrument calibration, satellite orbit sampling, and analysis methods. Unlike most space missions, the CLARREO requirements are driven not by the instantaneous accuracy of the measurements, but by accuracy in the large time/space scale averages that are key to understanding decadal changes.

  9. High-Reynolds Number Circulation Control Testing in the National Transonic Facility

    NASA Technical Reports Server (NTRS)

    Milholen, William E., II; Jones, Gregory S.; Chan, David T.; Goodliff, Scott L.

    2012-01-01

    A new capability to test active flow control concepts and propulsion simulations at high Reynolds numbers in the National Transonic Facility at the NASA Langley Research Center is being developed. The first active flow control experiment was completed using the new FAST-MAC semi-span model to study Reynolds number scaling effects for several circulation control concepts. Testing was conducted over a wide range of Mach numbers, up to chord Reynolds numbers of 30 million. The model was equipped with four onboard flow control valves allowing independent control of the circulation control plenums, which were directed over a 15% chord simple-hinged flap. Preliminary analysis of the uncorrected lift data showed that the circulation control increased the low-speed maximum lift coefficient by 33%. At transonic speeds, the circulation control was capable of positively altering the shockwave pattern on the upper wing surface and reducing flow separation. Furthermore, application of the technique to only the outboard portion of the wing demonstrated the feasibility of a pneumatic based roll control capability.

  10. A Community Data Model for Hydrologic Observations

    NASA Astrophysics Data System (ADS)

    Tarboton, D. G.; Horsburgh, J. S.; Zaslavsky, I.; Maidment, D. R.; Valentine, D.; Jennings, B.

    2006-12-01

    The CUAHSI Hydrologic Information System project is developing information technology infrastructure to support hydrologic science. Hydrologic information science involves the description of hydrologic environments in a consistent way, using data models for information integration. This includes a hydrologic observations data model for the storage and retrieval of hydrologic observations in a relational database designed to facilitate data retrieval for integrated analysis of information collected by multiple investigators. It is intended to provide a standard format to facilitate the effective sharing of information between investigators and to facilitate analysis of information within a single study area or hydrologic observatory, or across hydrologic observatories and regions. The observations data model is designed to store hydrologic observations and sufficient ancillary information (metadata) about the observations to allow them to be unambiguously interpreted and used and provide traceable heritage from raw measurements to usable information. The design is based on the premise that a relational database at the single observation level is most effective for providing querying capability and cross dimension data retrieval and analysis. This premise is being tested through the implementation of a prototype hydrologic observations database, and the development of web services for the retrieval of data from and ingestion of data into the database. These web services hosted by the San Diego Supercomputer center make data in the database accessible both through a Hydrologic Data Access System portal and directly from applications software such as Excel, Matlab and ArcGIS that have Standard Object Access Protocol (SOAP) capability. This paper will (1) describe the data model; (2) demonstrate the capability for representing diverse data in the same database; (3) demonstrate the use of the database from applications software for the performance of hydrologic analysis across different observation types.

  11. EVA Systems Technology Gaps and Priorities 2017

    NASA Technical Reports Server (NTRS)

    Johnson, Brian J.; Buffington, Jesse A.

    2017-01-01

    Performance of Extra-Vehicular Activities (EVA) has been and will continue to be a critical capability for human space flight. Human exploration missions beyond LEO will require EVA capability for either contingency or nominal activities to support mission objectives and reduce mission risk. EVA systems encompass a wide array of products across pressure suits, life support systems, EVA tools and unique spacecraft interface hardware (i.e. EVA Translation Paths and EVA Worksites). In a fiscally limited environment with evolving transportation and habitation options, it is paramount that the EVA community's strategic planning and architecture integration products be reviewed and vetted for traceability between the mission needs far into the future to the known technology and knowledge gaps to the current investments across EVA systems. To ascertain EVA technology and knowledge gaps many things need to be brought together, assessed and analyzed. This includes an understanding of the destination environments, various mission concept of operations, current state of the art of EVA systems, EVA operational lessons learned, and reference advanced capabilities. A combined assessment of these inputs should result in well-defined list of gaps. This list can then be prioritized depending on the mission need dates and time scale of the technology or knowledge gap closure plan. This paper will summarize the current state of EVA related technology and knowledge gaps derived from NASA's Exploration EVA Reference Architecture and Operations Concept products. By linking these products and articulating NASA's approach to strategic development for EVA across all credible destinations an EVA could be done in, the identification of these gaps is then used to illustrate the tactical and strategic planning for the EVA technology development portfolio. Finally, this paper illustrates the various "touch points" with other human exploration risk identification areas including human health and performance.

  12. Development, characterization, and validation of an optical transfer standard for ammonia in air

    NASA Astrophysics Data System (ADS)

    Lüttschwager, Nils; Balslev-Harder, David; Leuenberger, Daiana; Pogány, Andrea; Werhahn, Olav; Ebert, Volker

    2017-04-01

    Ammonia is an atmospheric trace gas that is predominantly emitted from anthropogenic agricultural activities. Since elevated levels of ammonia can have negative effects to human health as well as ecosystems, it is imperative to monitor and control ammonia emissions. This requires SI-traceable standards to calibrate ammonia monitoring instrumentation and to make measurements comparable. The lack of such standards became a pressing issue in recent years and the MetNH3 project (www.metnh3.eu) was initiated to fill the gap, pursuing different strategies. The work that we present was part of these endeavours and focusses on the development and application of an optical transfer standard for amount fraction measurements of ammonia in ambient air. An optical transfer standard (OTS) offers an alternative to calibrations of air monitoring instrumentation by means of reference gas mixtures. With an OTS, absolute amount fraction results are derived by evaluating absorption spectra using a spectral model and pre-measured spectral properties of the analyte. In that way, the instrument can measure calibration gas-independent ("calibration-free") and, moreover, can itself serve as standard to calibrate air monitoring analyzers. Molecular spectral properties are the excellent, non-drifting point of reference of the OTS and form, together with traceable measurements of temperature and pressure, the basis for SI-traceable amount fraction measurements. We developed an OTS based on a commercial cavity-ring-down spectrometer with a detection limit below 1 ppb (1 nmol/mol). A custom spectral data evaluation routine for absolute, calibration-free measurements, as well as measurements of spectral properties of ammonia with the focus on measurement uncertainty and traceability [1] are the fundaments of our OTS. Validation measurements were conducted using a SI-traceable ammonia reference gas generator over a period of several months. Here, we present an evaluation of the performance of our OTS from 1 ppb to 200 ppb. We found the results obtained with the OTS to be concordant to reference gas mixtures yielding amount fraction results with standard uncertainties of less than 3 %, for which an uncertainty budget is provided. Acknowledgement: This work was supported by the European Metrology Research Programme (EMRP). The EMRP is jointly funded by the EMRP participating countries within EURAMET and the European Union. References 1. A. Pogány, O. Werhahn, and V. Ebert, High-Accuracy Ammonia Line Intensity Measurements at 1.5 µm, in Imaging and Applied Optics 2016, OSA Technical Digest (online) (Optical Society of America, 2016), paper JT3A.15, DOI: 10.1364/3D.2016.JT3A.15

  13. Vortices in Long Josephson Junctions.

    DTIC Science & Technology

    1987-11-01

    of the very low impedance vortex flow transistor and toward determination of its potential for high frequency applications. Capability for higher...version. New progress was made toward solution of the problems of high frequency testing of the very low impedance vortex flow transistor and towards... measurable transresistance ’". out to frequencies of about 10% of the theoretical transit time cutoff fre- quency. Capability for higher frequency testing

  14. Development and Validation of an Automated Simulation Capability in Support of Integrated Demand Management

    NASA Technical Reports Server (NTRS)

    Arneson, Heather; Evans, Antony D.; Li, Jinhua; Wei, Mei Yueh

    2017-01-01

    Integrated Demand Management (IDM) is a near- to mid-term NASA concept that proposes to address mismatches in air traffic system demand and capacity by using strategic flow management capabilities to pre-condition demand into the more tactical Time-Based Flow Management System (TBFM). This paper describes an automated simulation capability to support IDM concept development. The capability closely mimics existing human-in-the-loop (HITL) capabilities, automating both the human components and collaboration between operational systems, and speeding up the real-time aircraft simulations. Such a capability allows for parametric studies that will inform the HITL simulations, identifying breaking points and parameter values at which significant changes in system behavior occur. This paper also describes the initial validation of individual components of the automated simulation capability, and an example application comparing the performance of the IDM concept under two TBFM scheduling paradigms. The results and conclusions from this simulation compare closely to those from previous HITL simulations using similar scenarios, providing an initial validation of the automated simulation capability.

  15. Exploring Online Game Players' Flow Experiences and Positive Affect

    ERIC Educational Resources Information Center

    Chiang, Yu-Tzu; Lin, Sunny S. J.; Cheng, Chao-Yang; Liu, Eric Zhi-Feng

    2011-01-01

    The authors conducted two studies to explore online game players' flow experiences and positive affect. Our findings indicated that online game are capable of evoking flow experiences and positive affect, and games of violent or nonviolent type may not arouse players' aggression. The players could be placed into four flow conditions: flow,…

  16. Lagrangian turbulence: Structures and mixing in admissible model flows

    NASA Astrophysics Data System (ADS)

    Ottino, Julio M.

    1991-12-01

    The goal of our research was to bridge the gap between modern ideas from dynamical systems and chaos and more traditional approaches to turbulence. In order to reach this objective we conducted theoretical and computational work on two systems: (1) a perturbed-Kelvin cat eyes flow, and (2) prototype solutions of the Navier-Stokes equations near solid walls. The main results obtained are two-fold: we have been able to produce flows capable of producing complex distributions of vorticity, and we have been able to construct flowfields, based on solutions of the Navier-Stokes equations, which are capable of displaying both Eulerian and Lagrangian turbulence. These results exemplify typical mechanisms of mixing enhancement in transitional flows.

  17. Interfacing a General Purpose Fluid Network Flow Program with the SINDA/G Thermal Analysis Program

    NASA Technical Reports Server (NTRS)

    Schallhorn, Paul; Popok, Daniel

    1999-01-01

    A general purpose, one dimensional fluid flow code is currently being interfaced with the thermal analysis program Systems Improved Numerical Differencing Analyzer/Gaski (SINDA/G). The flow code, Generalized Fluid System Simulation Program (GFSSP), is capable of analyzing steady state and transient flow in a complex network. The flow code is capable of modeling several physical phenomena including compressibility effects, phase changes, body forces (such as gravity and centrifugal) and mixture thermodynamics for multiple species. The addition of GFSSP to SINDA/G provides a significant improvement in convective heat transfer modeling for SINDA/G. The interface development is conducted in multiple phases. This paper describes the first phase of the interface which allows for steady and quasi-steady (unsteady solid, steady fluid) conjugate heat transfer modeling.

  18. Balancing detail and scale in assessing transparency to improve the governance of agricultural commodity supply chains

    NASA Astrophysics Data System (ADS)

    Godar, Javier; Suavet, Clément; Gardner, Toby A.; Dawkins, Elena; Meyfroidt, Patrick

    2016-03-01

    To date, assessments of the sustainability of agricultural commodity supply chains have largely relied on some combination of macro-scale footprint accounts, detailed life-cycle analyses and fine-scale traceability systems. Yet these approaches are limited in their ability to support the sustainability governance of agricultural supply chains, whether because they are intended for coarser-grained analyses, do not identify individual actors, or are too costly to be implemented in a consistent manner for an entire region of production. Here we illustrate some of the advantages of a complementary middle-ground approach that balances detail and scale of supply chain transparency information by combining consistent country-wide data on commodity production at the sub-national (e.g. municipal) level with per shipment customs data to describe trade flows of a given commodity covering all companies and production regions within that country. This approach can support supply chain governance in two key ways. First, enhanced spatial resolution of the production regions that connect to individual supply chains allows for a more accurate consideration of geographic variability in measures of risk and performance that are associated with different production practices. Second, identification of key actors that operate within a specific supply chain, including producers, traders, shippers and consumers can help discriminate coalitions of actors that have shared stake in a particular region, and that together are capable of delivering more cost-effective and coordinated interventions. We illustrate the potential of this approach with examples from Brazil, Indonesia and Colombia. We discuss how transparency information can deepen understanding of the environmental and social impacts of commodity production systems, how benefits are distributed among actors, and some of the trade-offs involved in efforts to improve supply chain sustainability. We then discuss the challenges and opportunities of our approach to strengthen supply chain governance and leverage more effective and fair accountability systems.

  19. Advances in Computational Capabilities for Hypersonic Flows

    NASA Technical Reports Server (NTRS)

    Kumar, Ajay; Gnoffo, Peter A.; Moss, James N.; Drummond, J. Philip

    1997-01-01

    The paper reviews the growth and advances in computational capabilities for hypersonic applications over the period from the mid-1980's to the present day. The current status of the code development issues such as surface and field grid generation, algorithms, physical and chemical modeling, and validation is provided. A brief description of some of the major codes being used at NASA Langley Research Center for hypersonic continuum and rarefied flows is provided, along with their capabilities and deficiencies. A number of application examples are presented, and future areas of research to enhance accuracy, reliability, efficiency, and robustness of computational codes are discussed.

  20. Computation of Reacting Flows in Combustion Processes

    NASA Technical Reports Server (NTRS)

    Keith, Theo G., Jr.; Chen, Kuo-Huey

    1997-01-01

    The main objective of this research was to develop an efficient three-dimensional computer code for chemically reacting flows. The main computer code developed is ALLSPD-3D. The ALLSPD-3D computer program is developed for the calculation of three-dimensional, chemically reacting flows with sprays. The ALL-SPD code employs a coupled, strongly implicit solution procedure for turbulent spray combustion flows. A stochastic droplet model and an efficient method for treatment of the spray source terms in the gas-phase equations are used to calculate the evaporating liquid sprays. The chemistry treatment in the code is general enough that an arbitrary number of reaction and species can be defined by the users. Also, it is written in generalized curvilinear coordinates with both multi-block and flexible internal blockage capabilities to handle complex geometries. In addition, for general industrial combustion applications, the code provides both dilution and transpiration cooling capabilities. The ALLSPD algorithm, which employs the preconditioning and eigenvalue rescaling techniques, is capable of providing efficient solution for flows with a wide range of Mach numbers. Although written for three-dimensional flows in general, the code can be used for two-dimensional and axisymmetric flow computations as well. The code is written in such a way that it can be run in various computer platforms (supercomputers, workstations and parallel processors) and the GUI (Graphical User Interface) should provide a user-friendly tool in setting up and running the code.

  1. 48 CFR 211.274-1 - General.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... on the workforce through increased productivity and efficiency; and (e) Ensures item level traceability throughout lifecycle to strengthen supply chain integrity, enhance cyber security, and combat...

  2. Inviscid and viscous flow modelling of complex aircraft configurations using the CFD simulation system sauna

    NASA Astrophysics Data System (ADS)

    Peace, Andrew J.; May, Nicholas E.; Pocock, Mark F.; Shaw, Jonathon A.

    1994-04-01

    This paper is concerned with the flow modelling capabilities of an advanced CFD simulation system known by the acronym SAUNA. This system is aimed primarily at complex aircraft configurations and possesses a unique grid generation strategy in its use of block-structured, unstructured or hybrid grids, depending on the geometric complexity of the addressed configuration. The main focus of the paper is in demonstrating the recently developed multi-grid, block-structured grid, viscous flow capability of SAUNA, through its evaluation on a number of configurations. Inviscid predictions are also presented, both as a means of interpreting the viscous results and with a view to showing more completely the capabilities of SAUNA. It is shown that accuracy and flexibility are combined in an efficient manner, thus demonstrating the value of SAUNA in aerodynamic design.

  3. Traceable Co-C eutectic points for thermocouple calibration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jahan, F.; Ballico, M. J.

    2013-09-11

    National Measurement Institute of Australia (NMIA) has developed a miniature crucible design suitable for measurement by both thermocouples and radiation thermometry, and has established an ensemble of five Co-C eutectic-point cells based on this design. The cells in this ensemble have been individually calibrated using both ITS-90 radiation thermometry and thermocouples calibrated on the ITS-90 by the NMIA mini-coil methodology. The assigned ITS-90 temperatures obtained using these different techniques are both repeatable and consistent, despite the use of different furnaces and measurement conditions. The results demonstrate that, if individually calibrated, such cells can be practically used as part of amore » national traceability scheme for thermocouple calibration, providing a useful intermediate calibration point between Cu and Pd.« less

  4. Spatial and Temporal Analysis of Bias HAST System Temperature

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pfeifer, Kent B.; Furrer, III, Clint T; Sandoval, Paul Anthony

    2017-03-01

    High-reliability components for high-consequence systems require detailed testing of operation after having undergone highly accelerated stress testing (HAST) under unusual conditions of high-temperature and humidity. This paper describes the design and operation of a system called "Wormwood" that is a highly multiplexed temperature measurement system that is designed to operate under HAST conditions to allow measurement of the temperature as a function of time and position in a HAST chamber. HAST chambers have single-point temperature measurements that can be traceable to NIST standards. The objective of these "Wormwood" measurements is to verify the uniformity and stability of the remaining volumemore » of the HAST chamber with respect to the single traceable standard.« less

  5. Fracture trends identified by ERTS-1 imagery in Utah and Nevada

    NASA Technical Reports Server (NTRS)

    Jensen, M. L. (Principal Investigator); Smith, M. R.; Rogers, R. J.

    1973-01-01

    The author has identified the following significant results. Structures clearly traceable through bed rock are considered most reliable. Continuity, however, is frequently traceable through ranges and across adjoining sedimentary basins where changes in drainage, erosion pattern, soil color, or vegetation suggest that the basin sediments are extremely sensitive to underlying structures. Many large and continuous trends, too smeared by erosion to be visible on the ground or from aircraft photos, become quite evident at the scale of the ERTS-1 images. The study was made with little regard for surface geology. The trends have been retraced to separate and unidirectional sets. These are now being related to surface geology, geophysical studies, volcanic and intrusive centers, and areas of mineralization.

  6. Determination of radionuclides in environmental test items at CPHR: traceability and uncertainty calculation.

    PubMed

    Carrazana González, J; Fernández, I M; Capote Ferrera, E; Rodríguez Castro, G

    2008-11-01

    Information about how the laboratory of Centro de Protección e Higiene de las Radiaciones (CPHR), Cuba establishes its traceability to the International System of Units for the measurement of radionuclides in environmental test items is presented. A comparison among different methodologies of uncertainty calculation, including an analysis of the feasibility of using the Kragten-spreadsheet approach, is shown. In the specific case of the gamma spectrometric assay, the influence of each parameter, and the identification of the major contributor, in the relative difference between the methods of uncertainty calculation (Kragten and partial derivative) is described. The reliability of the uncertainty calculation results reported by the commercial software Gamma 2000 from Silena is analyzed.

  7. Visualization of Flow Separation Around an Atmospheric Entry Capsule at Low-Subsonic Mach Number Using Background-Oriented Schlieren (BOS)

    NASA Technical Reports Server (NTRS)

    Mizukaki, Toshiharu; Borg, Stephen E.; Danehy, Paul M.; Murman, Scott M.

    2014-01-01

    This paper presents the results of visualization of separated flow around a generic entry capsule that resembles the Apollo Command Module (CM) and the Orion Multi-Purpose Crew Vehicle (MPCV). The model was tested at flow speeds up to Mach 0.4 at a single angle of attack of 28 degrees. For manned spacecraft using capsule-shaped vehicles, certain flight operations such as emergency abort maneuvers soon after launch and flight just prior to parachute deployment during the final stages of entry, the command module may fly at low Mach number. Under these flow conditions, the separated flow generated from the heat-shield surface on both windward and leeward sides of the capsule dominates the wake flow downstream of the capsule. In this paper, flow visualization of the separated flow was conducted using the background-oriented schlieren (BOS) method, which has the capability of visualizing significantly separated wake flows without the particle seeding required by other techniques. Experimental results herein show that BOS has detection capability of density changes on the order of 10(sup-5).

  8. The flow of E-waste material in the Asian region and a reconsideration of international trade policies on E-waste

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shinkuma, Takayoshi; Nguyen Thi Minh Huong

    End-of-life home appliances discarded in Japan are reused in Southeast Asia; end-of-life computers are reused in China. E-waste scrap generated in Asia is recycled in China, especially in Guangdong Province. The informal sector in that province has been recycling E-waste scrap and its improper recycling methods have caused serious pollution. In response to this problem, there is wide support for a total ban on E-waste trade, including secondhand items and E-waste scrap. Alternatively, we recommend the establishment of an alternative proper recycling system in Asia that needs cooperation among all Asian countries. First, China is urged to promote proper domesticmore » recycling activities by providing a subsidy for proper recycling. Second, Japan, as a main exporter of E-waste, should establish a traceability system that ensures E-waste scrap exported from Japan will be recycled at proper recycling facilities in China.« less

  9. Microdialysis as a New Technique for Extracting Phenolic Compounds from Extra Virgin Olive Oil.

    PubMed

    Bazzu, Gianfranco; Molinu, Maria Giovanna; Dore, Antonio; Serra, Pier Andrea

    2017-03-01

    The amount and composition of the phenolic components play a major role in determining the quality of olive oil. The traditional liquid-liquid extraction (LLE) method requires a time-consuming sample preparation to obtain the "phenolic profile" of extra virgin olive oil (EVOO). This study aimed to develop a microdialysis extraction (MDE) as an alternative to the LLE method to evaluate the phenolic components of EVOO. To this purpose, a microdialysis device and dialysis procedure were developed. "Dynamic-oil" microdialysis was performed using an extracting solution (80:20 methanol/water) flow rate of 2 μL min -1 and a constant EVOO stream of 4 μL min -1 . The results indicated a strong positive correlation between MDE and the LLE method, providing a very similar phenolic profile obtained with traditional LLE. In conclusion, the MDE approach, easier and quicker in comparison to LLE, provided a reliable procedure to determine the phenolic components used as a marker of the quality and traceability of EVOO.

  10. Physical properties of biological entities: an introduction to the ontology of physics for biology.

    PubMed

    Cook, Daniel L; Bookstein, Fred L; Gennari, John H

    2011-01-01

    As biomedical investigators strive to integrate data and analyses across spatiotemporal scales and biomedical domains, they have recognized the benefits of formalizing languages and terminologies via computational ontologies. Although ontologies for biological entities-molecules, cells, organs-are well-established, there are no principled ontologies of physical properties-energies, volumes, flow rates-of those entities. In this paper, we introduce the Ontology of Physics for Biology (OPB), a reference ontology of classical physics designed for annotating biophysical content of growing repositories of biomedical datasets and analytical models. The OPB's semantic framework, traceable to James Clerk Maxwell, encompasses modern theories of system dynamics and thermodynamics, and is implemented as a computational ontology that references available upper ontologies. In this paper we focus on the OPB classes that are designed for annotating physical properties encoded in biomedical datasets and computational models, and we discuss how the OPB framework will facilitate biomedical knowledge integration. © 2011 Cook et al.

  11. Measuring Pressure Has a New Standard

    NASA Technical Reports Server (NTRS)

    2002-01-01

    The Force-Balanced Piston Gauge (FPG) tests and calibrates instrumentation operating in the low pressure range. The system provides a traceable, primary calibration standard for measuring pressures in the range of near 0 to 15 kPa (2.2 psi) in both gauge and absolute measurement modes. The hardware combines a large area piston-cylinder with a load cell measuring the force resulting from pressures across the piston. The mass of the piston can be tared out, allowing measurement to start from zero. A pressure higher than the measured pressure, which keeps the piston centered, lubricates an innovative conical gap located between the piston and the cylinder, eliminating the need for piston rotation. A pressure controller based on the control of low gas flow automates the pressure control. DHI markets the FPG as an automated primary standard for very low-gauge and absolute pressures. DHI is selling the FPG to high-end metrology laboratories on a case by case basis, with a full commercial release to follow.

  12. Traffic flow simulation for an urban freeway corridor

    DOT National Transportation Integrated Search

    1998-01-01

    The objective of this paper is to develop a realistic and operational macroscopic traffic flow simulation model which requires relatively less data collection efforts. Such a model should be capable of delineating the dynamics of traffic flow created...

  13. Confined turbulent swirling recirculating flow predictions. Ph.D. Thesis. Final Report

    NASA Technical Reports Server (NTRS)

    Abujelala, M. T.; Lilley, D. G.

    1985-01-01

    The capability and the accuracy of the STARPIC computer code in predicting confined turbulent swirling recirculating flows is presented. Inlet flow boundary conditions were demonstrated to be extremely important in simulating a flowfield via numerical calculations. The degree of swirl strength and expansion ratio have strong effects on the characteristics of swirling flow. In a nonswirling flow, a large corner recirculation zone exists in the flowfield with an expansion ratio greater than one. However, as the degree of inlet swirl increases, the size of this zone decreases and a central recirculation zone appears near the inlet. Generally, the size of the central zone increased with swirl strength and expansion ratio. Neither the standard k-epsilon turbulence mode nor its previous extensions show effective capability for predicting confined turbulent swirling recirculating flows. However, either reduced optimum values of three parameters in the mode or the empirical C sub mu formulation obtained via careful analysis of available turbulence measurements, can provide more acceptable accuracy in the prediction of these swirling flows.

  14. Background-Oriented Schlieren (BOS) for Scramjet Inlet-isolator Investigation

    NASA Astrophysics Data System (ADS)

    Che Idris, Azam; Rashdan Saad, Mohd; Hing Lo, Kin; Kontis, Konstantinos

    2018-05-01

    Background-oriented Schlieren (BOS) technique is a recently invented non-intrusive flow diagnostic method which has yet to be fully explored in its capabilities. In this paper, BOS technique has been applied for investigating the general flow field characteristics inside a generic scramjet inlet-isolator with Mach 5 flow. The difficulty in finding the delicate balance between measurement sensitivity and measurement area image focusing has been demonstrated. The differences between direct cross-correlation (DCC) and Fast Fourier Transform (FFT) raw data processing algorithm have also been demonstrated. As an exploratory study of BOS capability, this paper found that BOS is simple yet robust enough to be used to visualize complex flow in a scramjet inlet in hypersonic flow. However, in this case its quantitative data can be strongly affected by 3-dimensionality thus obscuring the density value with significant errors.

  15. A Steady State and Quasi-Steady Interface Between the Generalized Fluid System Simulation Program and the SINDA/G Thermal Analysis Program

    NASA Technical Reports Server (NTRS)

    Schallhorn, Paul; Majumdar, Alok; Tiller, Bruce

    2001-01-01

    A general purpose, one dimensional fluid flow code is currently being interfaced with the thermal analysis program SINDA/G. The flow code, GFSSP, is capable of analyzing steady state and transient flow in a complex network. The flow code is capable of modeling several physical phenomena including compressibility effects, phase changes, body forces (such as gravity and centrifugal) and mixture thermodynamics for multiple species. The addition of GFSSP to SINDA/G provides a significant improvement in convective heat transfer modeling for SINDA/G. The interface development is conducted in multiple phases. This paper describes the first phase of the interface which allows for steady and quasisteady (unsteady solid, steady fluid) conjugate heat transfer modeling.

  16. Accurate Radiometry from Space: An Essential Tool for Climate Studies

    NASA Technical Reports Server (NTRS)

    Fox, Nigel; Kaiser-Weiss, Andrea; Schmutz, Werner; Thome, Kurtis; Young, Dave; Wielicki, Bruce; Winkler, Rainer; Woolliams, Emma

    2011-01-01

    The Earth s climate is undoubtedly changing; however, the time scale, consequences and causal attribution remain the subject of significant debate and uncertainty. Detection of subtle indicators from a background of natural variability requires measurements over a time base of decades. This places severe demands on the instrumentation used, requiring measurements of sufficient accuracy and sensitivity that can allow reliable judgements to be made decades apart. The International System of Units (SI) and the network of National Metrology Institutes were developed to address such requirements. However, ensuring and maintaining SI traceability of sufficient accuracy in instruments orbiting the Earth presents a significant new challenge to the metrology community. This paper highlights some key measurands and applications driving the uncertainty demand of the climate community in the solar reflective domain, e.g. solar irradiances and reflectances/radiances of the Earth. It discusses how meeting these uncertainties facilitate significant improvement in the forecasting abilities of climate models. After discussing the current state of the art, it describes a new satellite mission, called TRUTHS, which enables, for the first time, high-accuracy SI traceability to be established in orbit. The direct use of a primary standard and replication of the terrestrial traceability chain extends the SI into space, in effect realizing a metrology laboratory in space . Keywords: climate change; Earth observation; satellites; radiometry; solar irradiance

  17. Metrologically Traceable Determination of the Water Content in Biopolymers: INRiM Activity

    NASA Astrophysics Data System (ADS)

    Rolle, F.; Beltramino, G.; Fernicola, V.; Sega, M.; Verdoja, A.

    2017-03-01

    Water content in materials is a key factor affecting many chemical and physical properties. In polymers of biological origin, it influences their stability and mechanical properties as well as their biodegradability. The present work describes the activity carried out at INRiM on the determination of water content in samples of a commercial starch-derived biopolymer widely used in shopping bags (Mater-Bi^{circledR }). Its water content, together with temperature, is the most influencing parameter affecting its biodegradability, because of the considerable impact on the microbial activity which is responsible for the biopolymer degradation in the environment. The main scope of the work was the establishment of a metrologically traceable procedure for the determination of water content by using two electrochemical methods, namely coulometric Karl Fischer (cKF) titration and evolved water vapour (EWV) analysis. The obtained results are presented. The most significant operational parameters were considered, and a particular attention was devoted to the establishment of metrological traceability of the measurement results by using appropriate calibration procedures, calibrated standards and suitable certified reference materials. Sample homogeneity and oven-drying temperature were found to be the most important influence quantities in the whole water content measurement process. The results of the two methods were in agreement within the stated uncertainties. Further development is foreseen for the application of cKF and EWV to other polymers.

  18. Varietal Tracing of Virgin Olive Oils Based on Plastid DNA Variation Profiling

    PubMed Central

    Pérez-Jiménez, Marga; Besnard, Guillaume; Dorado, Gabriel; Hernandez, Pilar

    2013-01-01

    Olive oil traceability remains a challenge nowadays. DNA analysis is the preferred approach to an effective varietal identification, without any environmental influence. Specifically, olive organelle genomics is the most promising approach for setting up a suitable set of markers as they would not interfere with the pollinator variety DNA traces. Unfortunately, plastid DNA (cpDNA) variation of the cultivated olive has been reported to be low. This feature could be a limitation for the use of cpDNA polymorphisms in forensic analyses or oil traceability, but rare cpDNA haplotypes may be useful as they can help to efficiently discriminate some varieties. Recently, the sequencing of olive plastid genomes has allowed the generation of novel markers. In this study, the performance of cpDNA markers on olive oil matrices, and their applicability on commercial Protected Designation of Origin (PDO) oils were assessed. By using a combination of nine plastid loci (including multi-state microsatellites and short indels), it is possible to fingerprint six haplotypes (in 17 Spanish olive varieties), which can discriminate high-value commercialized cultivars with PDO. In particular, a rare haplotype was detected in genotypes used to produce a regional high-value commercial oil. We conclude that plastid haplotypes can help oil traceability in commercial PDO oils and set up an experimental methodology suitable for organelle polymorphism detection in the complex olive oil matrices. PMID:23950947

  19. Improved reliability of pH measurements.

    PubMed

    Spitzer, Petra; Werner, Barbara

    2002-11-01

    Measurements of pH are performed on a large scale at laboratory level, and in industry. To meet the quality-control requirements and other technical specifications there is a need for traceability in measurement results. The prerequisite for the international acceptance of analytical data is reliability. To measure means to compare. Comparability entails use of recognised references to which the standard buffer solutions used for calibration of pH meter-electrode assemblies can be traced. The new recommendation on the measurement of pH recently published as a provisional document by the International Union on Pure and Applied Chemistry (IUPAC) enables traceability for measured pH values to a conventional reference frame which is recognised world-wide. The primary method for pH will be described. If analytical data are to be accepted internationally it is necessary to demonstrate the equivalence of the national traceability structures, including national measurement standards. For the first time key comparisons for pH have been performed by the Consultative Committee for Amount of Substance (CCQM, set up by the International Bureau of Weights and Measures, BIPM) to assess the equivalence of the national measurement procedures used to determine the pH of primary standard buffer solutions. The results of the first key comparison on pH CCQM-K9, and other international initiatives to improve the consistency of the results of measurement for pH, are reported.

  20. NIST Stars: Absolute Spectrophotometric Calibration of Vega and Sirius

    NASA Astrophysics Data System (ADS)

    Deustua, Susana; Woodward, John T.; Rice, Joseph P.; Brown, Steven W.; Maxwell, Stephen E.; Alberding, Brian G.; Lykke, Keith R.

    2018-01-01

    Absolute flux calibration of standard stars, traceable to SI (International System of Units) standards, is essential for 21st century astrophysics. Dark energy investigations that rely on observations of Type Ia supernovae and precise photometric redshifts of weakly lensed galaxies require a minimum accuracy of 0.5 % in the absolute color calibration. Studies that aim to address fundamental stellar astrophysics also benefit. In the era of large telescopes and all sky surveys well-calibrated standard stars that do not saturate and that are available over the whole sky are needed. Significant effort has been expended to obtain absolute measurements of the fundamental standards Vega and Sirius (and other stars) in the visible and near infrared, achieving total uncertainties between1% and 3%, depending on wavelength, that do not meet the needed accuracy. The NIST Stars program aims to determine the top-of-the-atmosphere absolute spectral irradiance of bright stars to an uncertainty less than 1% from a ground-based observatory. NIST Stars has developed a novel, fully SI-traceable laboratory calibration strategy that will enable achieving the desired accuracy. This strategy has two key components. The first is the SI-traceable calibration of the entire instrument system, and the second is the repeated spectroscopic measurement of the target star throughout the night. We will describe our experimental strategy, present preliminary results for Vega and Sirius and an end-to-end uncertainty budget

  1. Current Lewis Turbomachinery Research: Building on our Legacy of Excellence

    NASA Technical Reports Server (NTRS)

    Povinelli, Louis A.

    1997-01-01

    This Wu Chang-Hua lecture is concerned with the development of analysis and computational capability for turbomachinery flows which is based on detailed flow field physics. A brief review of the work of Professor Wu is presented as well as a summary of the current NASA aeropropulsion programs. Two major areas of research are described in order to determine our predictive capabilities using modern day computational tools evolved from the work of Professor Wu. In one of these areas, namely transonic rotor flow, it is demonstrated that a high level of accuracy is obtainable provided sufficient geometric detail is simulated. In the second case, namely turbine heat transfer, our capability is lacking for rotating blade rows and experimental correlations will provide needed information in the near term. It is believed that continuing progress will allow us to realize the full computational potential and its impact on design time and cost.

  2. Development of small and inexpensive digital data acquisition systems using a microcontroller-based approach†

    PubMed Central

    Naivar, Mark A.; Wilder, Mark E.; Habbersett, Robert C.; Woods, Travis A.; Sebba, David S.; Nolan, John P.; Graves, Steven W.

    2014-01-01

    Fully digital data acquisition systems for use in flow cytometry provide excellent flexibility and precision. Here, we demonstrate the development of a low cost, small, and low power digital flow cytometry data acquisition system using a single microcontroller chip with an integrated analog to digital converter (ADC). Our demonstration system uses a commercially available evaluation board making the system simple to integrate into a flow cytometer. We have evaluated this system using calibration microspheres analyzed on commercial, slow-flow, and CCD based flow cytometers. In our evaluations, our demonstration data system clearly resolves all eight peaks of a Rainbow microsphere set on both a slow-flow flow cytometer and a retrofitted BD FACScalibur, which indicates it has the sensitivity and resolution required for most flow cytometry applications. It is also capable of millisecond time resolution, full waveform collection, and selective triggering of data collection from a CCD camera. The capability of our demonstration system suggests that the use of microcontrollers for flow cytometry digital data-acquisition will be increasingly valuable for extending the life of older cytometers and provides a compelling data-system design approach for low-cost, portable flow cytometers. PMID:19852060

  3. Development of small and inexpensive digital data acquisition systems using a microcontroller-based approach.

    PubMed

    Naivar, Mark A; Wilder, Mark E; Habbersett, Robert C; Woods, Travis A; Sebba, David S; Nolan, John P; Graves, Steven W

    2009-12-01

    Fully digital data acquisition systems for use in flow cytometry provide excellent flexibility and precision. Here, we demonstrate the development of a low cost, small, and low power digital flow cytometry data acquisition system using a single microcontroller chip with an integrated analog to digital converter (ADC). Our demonstration system uses a commercially available evaluation board making the system simple to integrate into a flow cytometer. We have evaluated this system using calibration microspheres analyzed on commercial, slow-flow, and CCD-based flow cytometers. In our evaluations, our demonstration data system clearly resolves all eight peaks of a Rainbow microsphere set on both a slow-flow flow cytometer and a retrofitted BD FACScalibur, which indicates it has the sensitivity and resolution required for most flow cytometry applications. It is also capable of millisecond time resolution, full waveform collection, and selective triggering of data collection from a CCD camera. The capability of our demonstration system suggests that the use of microcontrollers for flow cytometry digital data-acquisition will be increasingly valuable for extending the life of older cytometers and provides a compelling data-system design approach for low-cost, portable flow cytometers.

  4. Webcam-based flow cytometer using wide-field imaging for low cell number detection at high throughput.

    PubMed

    Balsam, Joshua; Bruck, Hugh Alan; Rasooly, Avraham

    2014-09-07

    Here we describe a novel low-cost flow cytometer based on a webcam capable of low cell number detection in a large volume which may overcome the limitations of current flow cytometry. Several key elements have been combined to yield both high throughput and high sensitivity. The first element is a commercially available webcam capable of 187 frames per second video capture at a resolution of 320 × 240 pixels. The second element in this design is a 1 W 450 nm laser module for area-excitation, which combined with the webcam allows for rapid interrogation of a flow field. The final element is a 2D flow-cell which overcomes the flow limitation of hydrodynamic focusing and allows for higher sample throughput in a wider flow field. This cell allows for the linear velocity of target cells to be lower than in a conventional "1D" hydrodynamic focusing flow-cells typically used in cytometry at similar volumetric flow rates. It also allows cells to be imaged at the full frame rate of the webcam. Using this webcam-based flow cytometer with wide-field imaging, it was confirmed that the detection of fluorescently tagged 5 μm polystyrene beads in "1D" hydrodynamic focusing flow-cells was not practical for low cell number detection due to streaking from the motion of the beads, which did not occur with the 2D flow-cell design. The sensitivity and throughput of this webcam-based flow cytometer was then investigated using THP-1 human monocytes stained with SYTO-9 florescent dye in the 2D flow-cell. The flow cytometer was found to be capable of detecting fluorescently tagged cells at concentrations as low as 1 cell per mL at flow rates of 500 μL min(-1) in buffer and in blood. The effectiveness of detection was concentration dependent: at 100 cells per mL 84% of the cells were detected compared to microscopy, 10 cells per mL 79% detected and 1 cell per mL 59% of the cells were detected. With the blood samples spiked to 100 cells per mL, the average concentration for all samples was 91.4 cells per mL, with a 95% confidence interval of 86-97 cells per mL. These low cell concentrations and the large volume capabilities of the system may overcome the limitations of current cytometry, and are applicable to rare cell (such as circulating tumor cell) detection The simplicity and low cost of this device suggests that it may have a potential use in developing point-of-care clinical flow cytometry for resource-poor settings associated with global health.

  5. 78 FR 13352 - Government-Owned Inventions; Availability for Licensing

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-27

    ... traceability for the receipt of raw materials from their source to the dispensing of finished pharmaceutical... MRI imaging Competitive Advantages: Improved resolution through composite imagery Background...

  6. Optimizing the Ar-Xe infrared laser on the Naval Research Laboratory's Electra generator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Apruzese, J. P.; Giuliani, J. L.; Wolford, M. F.

    2008-07-01

    The Ar-Xe infrared laser has been investigated in several series of experiments carried out on the Naval Research Laboratory's Electra generator. Our primary goals were to optimize the efficiency of the laser (within Electra's capabilities) and to gain understanding of the main physical processes underlying the laser's output as a function of controllable parameters such as Xe fraction, power deposition, and gas pressure. We find that the intrinsic efficiency maximizes at {approx}3% at a total pressure of 2.5 atm, Xe fraction of 1%, and electron beam power deposition density of 50-100 kW cm{sup -3}. We deployed an interferometer to measuremore » the electron density during lasing; the ionization fractions of 10{sup -5}-10{sup -4} that it detected well exceed previous theoretical estimates. Some trends in the data as a function of beam power and xenon fraction are not fully understood. The as-yet incomplete picture of Ar-Xe laser physics is likely traceable in large part to significant uncertainties still present in many important rates influencing the atomic and molecular kinetics.« less

  7. Three-dimensional fuse deposition modeling of tissue-simulating phantom for biomedical optical imaging

    NASA Astrophysics Data System (ADS)

    Dong, Erbao; Zhao, Zuhua; Wang, Minjie; Xie, Yanjun; Li, Shidi; Shao, Pengfei; Cheng, Liuquan; Xu, Ronald X.

    2015-12-01

    Biomedical optical devices are widely used for clinical detection of various tissue anomalies. However, optical measurements have limited accuracy and traceability, partially owing to the lack of effective calibration methods that simulate the actual tissue conditions. To facilitate standardized calibration and performance evaluation of medical optical devices, we develop a three-dimensional fuse deposition modeling (FDM) technique for freeform fabrication of tissue-simulating phantoms. The FDM system uses transparent gel wax as the base material, titanium dioxide (TiO2) powder as the scattering ingredient, and graphite powder as the absorption ingredient. The ingredients are preheated, mixed, and deposited at the designated ratios layer-by-layer to simulate tissue structural and optical heterogeneities. By printing the sections of human brain model based on magnetic resonance images, we demonstrate the capability for simulating tissue structural heterogeneities. By measuring optical properties of multilayered phantoms and comparing with numerical simulation, we demonstrate the feasibility for simulating tissue optical properties. By creating a rat head phantom with embedded vasculature, we demonstrate the potential for mimicking physiologic processes of a living system.

  8. Creation and Validation of Sintered PTFE BRDF Targets & Standards

    PubMed Central

    Durell, Christopher; Scharpf, Dan; McKee, Greg; L’Heureux, Michelle; Georgiev, Georgi; Obein, Gael; Cooksey, Catherine

    2016-01-01

    Sintered polytetrafluoroethylene (PTFE) is an extremely stable, near-perfect Lambertian reflecting diffuser and calibration standard material that has been used by national labs, space, aerospace and commercial sectors for over two decades. New uncertainty targets of 2 % on-orbit absolute validation in the Earth Observing Systems community have challenged the industry to improve is characterization and knowledge of almost every aspect of radiometric performance (space and ground). Assuming “near perfect” reflectance for angular dependent measurements is no longer going to suffice for many program needs. The total hemispherical spectral reflectance provides a good mark of general performance; but, without the angular characterization of bidirectional reflectance distribution function (BRDF) measurements, critical data is missing from many applications and uncertainty budgets. Therefore, traceable BRDF measurement capability is needed to characterize sintered PTFE’s angular response and provide a full uncertainty profile to users. This paper presents preliminary comparison measurements of the BRDF of sintered PTFE from several laboratories to better quantify the BRDF of sintered PTFE, assess the BRDF measurement comparability between laboratories, and improve estimates of measurement uncertainties under laboratory conditions. PMID:26900206

  9. Creation and Validation of Sintered PTFE BRDF Targets & Standards.

    PubMed

    Durell, Christopher; Scharpf, Dan; McKee, Greg; L'Heureux, Michelle; Georgiev, Georgi; Obein, Gael; Cooksey, Catherine

    2015-09-21

    Sintered polytetrafluoroethylene (PTFE) is an extremely stable, near-perfect Lambertian reflecting diffuser and calibration standard material that has been used by national labs, space, aerospace and commercial sectors for over two decades. New uncertainty targets of 2 % on-orbit absolute validation in the Earth Observing Systems community have challenged the industry to improve is characterization and knowledge of almost every aspect of radiometric performance (space and ground). Assuming "near perfect" reflectance for angular dependent measurements is no longer going to suffice for many program needs. The total hemispherical spectral reflectance provides a good mark of general performance; but, without the angular characterization of bidirectional reflectance distribution function (BRDF) measurements, critical data is missing from many applications and uncertainty budgets. Therefore, traceable BRDF measurement capability is needed to characterize sintered PTFE's angular response and provide a full uncertainty profile to users. This paper presents preliminary comparison measurements of the BRDF of sintered PTFE from several laboratories to better quantify the BRDF of sintered PTFE, assess the BRDF measurement comparability between laboratories, and improve estimates of measurement uncertainties under laboratory conditions.

  10. Power flows and Mechanical Intensities in structural finite element analysis

    NASA Technical Reports Server (NTRS)

    Hambric, Stephen A.

    1989-01-01

    The identification of power flow paths in dynamically loaded structures is an important, but currently unavailable, capability for the finite element analyst. For this reason, methods for calculating power flows and mechanical intensities in finite element models are developed here. Formulations for calculating input and output powers, power flows, mechanical intensities, and power dissipations for beam, plate, and solid element types are derived. NASTRAN is used to calculate the required velocity, force, and stress results of an analysis, which a post-processor then uses to calculate power flow quantities. The SDRC I-deas Supertab module is used to view the final results. Test models include a simple truss and a beam-stiffened cantilever plate. Both test cases showed reasonable power flow fields over low to medium frequencies, with accurate power balances. Future work will include testing with more complex models, developing an interactive graphics program to view easily and efficiently the analysis results, applying shape optimization methods to the problem with power flow variables as design constraints, and adding the power flow capability to NASTRAN.

  11. A Greenhouse-Gas Information System: Monitoring and Validating Emissions Reporting and Mitigation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jonietz, Karl K.; Dimotakis, Paul E.; Rotman, Douglas A.

    2011-09-26

    This study and report focus on attributes of a greenhouse-gas information system (GHGIS) needed to support MRV&V needs. These needs set the function of such a system apart from scientific/research monitoring of GHGs and carbon-cycle systems, and include (not exclusively): the need for a GHGIS that is operational, as required for decision-support; the need for a system that meets specifications derived from imposed requirements; the need for rigorous calibration, verification, and validation (CV&V) standards, processes, and records for all measurement and modeling/data-inversion data; the need to develop and adopt an uncertainty-quantification (UQ) regimen for all measurement and modeling data; andmore » the requirement that GHGIS products can be subjected to third-party questioning and scientific scrutiny. This report examines and assesses presently available capabilities that could contribute to a future GHGIS. These capabilities include sensors and measurement technologies; data analysis and data uncertainty quantification (UQ) practices and methods; and model-based data-inversion practices, methods, and their associated UQ. The report further examines the need for traceable calibration, verification, and validation processes and attached metadata; differences between present science-/research-oriented needs and those that would be required for an operational GHGIS; the development, operation, and maintenance of a GHGIS missions-operations center (GMOC); and the complex systems engineering and integration that would be required to develop, operate, and evolve a future GHGIS.« less

  12. Brayton Power Conversion System Study to Advance Technology Readiness for Nuclear Electric Propulsion

    NASA Technical Reports Server (NTRS)

    Allen, Bog; Delventhal, Rex; Frye, Patrick

    2004-01-01

    Recently, there has been significant interest within the aerospace community to develop space based nuclear power conversion technologies especially for exploring the outer planets of our solar system where the solar energy density is very low. To investigate these technologies NASA awarded several contracts under Project Prometheus, the Nuclear Systems Program. The studies described in this paper were performed under one of those contracts, which was to investigate the use of a nuclear power conversion system based on the closed Brayton cycle (CBC).The investigation performed included BPCS (Brayton Power Conversion System) trade studies to minimize system weight and radiator area and advance the state of the art of BPCS technology. The primary requirements for studies were a power level of 100 kWe (to the PPU), a low overall power system mass and a lifetime of 15 years (10 years full power). For the radiation environment, the system was to be capable of operation in the generic space environment and withstand the extreme environments surrounding Jupiter. The studies defined a BPCS design traceable to NEP (Nuclear Electric Propulsion) requirements and suitable for future missions with a sound technology plan for technology readiness level (TRL) advancement identified. The studies assumed a turbine inlet temperature approx. 100 C above the current the state of the art capabilities with materials issues and related development tasks identified. Analyses and evaluations of six different HRS (heat rejection system) designs and three primary power management and distribution (PMAD) configurations will be discussed in the paper.

  13. Unique Testing Capabilities of the NASA Langley Transonic Dynamics Tunnel, an Exercise in Aeroelastic Scaling

    NASA Technical Reports Server (NTRS)

    Ivanco, Thomas G.

    2013-01-01

    NASA Langley Research Center's Transonic Dynamics Tunnel (TDT) is the world's most capable aeroelastic test facility. Its large size, transonic speed range, variable pressure capability, and use of either air or R-134a heavy gas as a test medium enable unparalleled manipulation of flow-dependent scaling quantities. Matching these scaling quantities enables dynamic similitude of a full-scale vehicle with a sub-scale model, a requirement for proper characterization of any dynamic phenomenon, and many static elastic phenomena. Select scaling parameters are presented in order to quantify the scaling advantages of TDT and the consequence of testing in other facilities. In addition to dynamic testing, the TDT is uniquely well-suited for high risk testing or for those tests that require unusual model mount or support systems. Examples of recently conducted dynamic tests requiring unusual model support are presented. In addition to its unique dynamic test capabilities, the TDT is also evaluated in its capability to conduct aerodynamic performance tests as a result of its flow quality. Results of flow quality studies and a comparison to a many other transonic facilities are presented. Finally, the ability of the TDT to support future NASA research thrusts and likely vehicle designs is discussed.

  14. Software Aids Visualization of Computed Unsteady Flow

    NASA Technical Reports Server (NTRS)

    Kao, David; Kenwright, David

    2003-01-01

    Unsteady Flow Analysis Toolkit (UFAT) is a computer program that synthesizes motions of time-dependent flows represented by very large sets of data generated in computational fluid dynamics simulations. Prior to the development of UFAT, it was necessary to rely on static, single-snapshot depictions of time-dependent flows generated by flow-visualization software designed for steady flows. Whereas it typically takes weeks to analyze the results of a largescale unsteady-flow simulation by use of steady-flow visualization software, the analysis time is reduced to hours when UFAT is used. UFAT can be used to generate graphical objects of flow visualization results using multi-block curvilinear grids in the format of a previously developed NASA data-visualization program, PLOT3D. These graphical objects can be rendered using FAST, another popular flow visualization software developed at NASA. Flow-visualization techniques that can be exploited by use of UFAT include time-dependent tracking of particles, detection of vortex cores, extractions of stream ribbons and surfaces, and tetrahedral decomposition for optimal particle tracking. Unique computational features of UFAT include capabilities for automatic (batch) processing, restart, memory mapping, and parallel processing. These capabilities significantly reduce analysis time and storage requirements, relative to those of prior flow-visualization software. UFAT can be executed on a variety of supercomputers.

  15. 10 CFR 35.630 - Dosimetry equipment.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... system or source traceable to the National Institute of Standards and Technology (NIST) and published... American Association of Physicists in Medicine (AAPM). The calibration must have been performed within the...

  16. 10 CFR 35.630 - Dosimetry equipment.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... system or source traceable to the National Institute of Standards and Technology (NIST) and published... American Association of Physicists in Medicine (AAPM). The calibration must have been performed within the...

  17. 10 CFR 35.630 - Dosimetry equipment.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... system or source traceable to the National Institute of Standards and Technology (NIST) and published... American Association of Physicists in Medicine (AAPM). The calibration must have been performed within the...

  18. 10 CFR 35.630 - Dosimetry equipment.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... system or source traceable to the National Institute of Standards and Technology (NIST) and published... American Association of Physicists in Medicine (AAPM). The calibration must have been performed within the...

  19. 10 CFR 35.630 - Dosimetry equipment.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... system or source traceable to the National Institute of Standards and Technology (NIST) and published... American Association of Physicists in Medicine (AAPM). The calibration must have been performed within the...

  20. VisFlow - Web-based Visualization Framework for Tabular Data with a Subset Flow Model.

    PubMed

    Yu, Bowen; Silva, Claudio T

    2017-01-01

    Data flow systems allow the user to design a flow diagram that specifies the relations between system components which process, filter or visually present the data. Visualization systems may benefit from user-defined data flows as an analysis typically consists of rendering multiple plots on demand and performing different types of interactive queries across coordinated views. In this paper, we propose VisFlow, a web-based visualization framework for tabular data that employs a specific type of data flow model called the subset flow model. VisFlow focuses on interactive queries within the data flow, overcoming the limitation of interactivity from past computational data flow systems. In particular, VisFlow applies embedded visualizations and supports interactive selections, brushing and linking within a visualization-oriented data flow. The model requires all data transmitted by the flow to be a data item subset (i.e. groups of table rows) of some original input table, so that rendering properties can be assigned to the subset unambiguously for tracking and comparison. VisFlow features the analysis flexibility of a flow diagram, and at the same time reduces the diagram complexity and improves usability. We demonstrate the capability of VisFlow on two case studies with domain experts on real-world datasets showing that VisFlow is capable of accomplishing a considerable set of visualization and analysis tasks. The VisFlow system is available as open source on GitHub.

  1. Application studies of RFID technology in the process of coal logistics transport

    NASA Astrophysics Data System (ADS)

    Qiao, Bingqin; Chang, Xiaoming; Hao, Meiyan; Kong, Dejin

    2012-04-01

    For quality control problems in coal transport, RFID technology has been proposed to be applied to coal transportation process. The whole process RFID traceability system from coal production to consumption has been designed and coal supply chain logistics tracking system integration platform has been built, to form the coal supply chain traceability and transport tracking system and providing more and more transparent tracking and monitoring of coal quality information for consumers of coal. Currently direct transport and combined transport are the main forms of coal transportation in China. The means of transport are cars, trains and ships. In the booming networking environment of RFID technology, the RFID technology will be applied to coal logistics and provide opportunity for the coal transportation tracking in the process transportation.

  2. SI-Traceable Water Content Measurements in Solids, Bulks, and Powders

    NASA Astrophysics Data System (ADS)

    Østergaard, Peter; Nielsen, Jan

    2018-01-01

    Methods such as Karl Fischer titration and Loss-on-Drying, commonly used for estimating moisture content in samples, have been in existence for many years, but have difficulties obtaining a direct calibration chain toward water content. In recognition of this challenge, the joint research project, METefnet, was funded by the European Metrology Research Programme in 2012. The goal of METefnet is to establish a European metrology infrastructure for water content measurement and to develop primary standards for unambiguous determination of water mass fraction in materials. Here, we describe the primary standard developed by Danish Technological Institute in METefnet. This standard establishes traceability of the water content of a sample to dewpoint temperature. The standard only measures water, and the measurement result is not affected by other components.

  3. Enhanced Traceability for Bulk Processing of Sentinel-Derived Information Products

    NASA Astrophysics Data System (ADS)

    Lankester, Thomas; Hubbard, Steven; Knowelden, Richard

    2016-08-01

    The advent of widely available, systematically acquired and advanced Earth observations from the Sentinel platforms is spurring development of a wide range of derived information products. Whilst welcome, this rapid rate of development inevitably leads to some processing instability as algorithms and production steps are required to evolve accordingly. To mitigate this instability, the provenance of EO-derived information products needs to be traceable and transparent.Airbus Defence and Space (Airbus DS) has developed the Airbus Processing Cloud (APC) as a virtualised processing farm for bulk production of EO-derived data and information products. The production control system of the APC transforms internal configuration control information into an INSPIRE metadata file containing a stepwise set of processing steps and data source elements that provide the complete and transparent provenance of each product generated.

  4. The specifics of dosimetry for food irradiation applications

    NASA Astrophysics Data System (ADS)

    Kuntz, Florent; Strasser, Alain

    2016-12-01

    Dose measurement applied to food irradiation is obviously a very important and critical aspect of this process. It is described in many standards and guides. The application of appropriate dosimetry tools is explained. This helps to ensure traceability of this measurement and number of dosimeters available on the market are well studied even though theirs response should be characterized while used in routine processing conditions. When employed in low energy radiation fields, these dosimeters may exhibit specific response compared to the usual Cobalt 60 source irradiation. Traceable calibration or correction factor assessment of this energy dependency is mandatory. It is to mention that the absorbed dose is measured in the dosimeter itself and unfortunately not in/on the food product. However, existing dosimetry systems fulfill all relevant requirements.

  5. Metrological assurance and traceability for Industry 4.0 and additive manufacturing in Ukraine

    NASA Astrophysics Data System (ADS)

    Skliarov, Volodymyr; Neyezhmakov, Pavel; Prokopov, Alexander

    2018-03-01

    The national measurement standards from the point of view of traceability of the results of measurement in additive manufacturing in Ukraine are considered in the paper. The metrological characteristics of the national primary measurement standards in the field of geometric, temperature, optical-physical and time-frequency measurements, which took part in international comparisons within COOMET projects, are presented. The accurate geometric, temperature, optical-physical and time-frequency measurements are the key ones in controlling the quality of additive manufacturing. The use of advanced CAD/CAE/CAM systems allows to simulate the process of additive manufacturing at each stage. In accordance with the areas of the technology of additive manufacturing, the ways of improving the national measurement standards of Ukraine for the growing needs of metrology of additive manufacturing are considered.

  6. Tracing the Rationale Behind UML Model Change Through Argumentation

    NASA Astrophysics Data System (ADS)

    Jureta, Ivan J.; Faulkner, Stéphane

    Neglecting traceability—i.e., the ability to describe and follow the life of a requirement—is known to entail misunderstanding and miscommunication, leading to the engineering of poor quality systems. Following the simple principles that (a) changes to UML model instances ought be justified to the stakeholders, (b) justification should proceed in a structured manner to ensure rigor in discussions, critique, and revisions of model instances, and (c) the concept of argument instantiated in a justification process ought to be well defined and understood, the present paper introduces the UML Traceability through Argumentation Method (UML-TAM) to enable the traceability of design rationale in UML while allowing the appropriateness of model changes to be checked by analysis of the structure of the arguments provided to justify such changes.

  7. [Relevance of the hemovigilance regional database for the shared medical file identity server].

    PubMed

    Doly, A; Fressy, P; Garraud, O

    2008-11-01

    The French Health Products Safety Agency coordinates the national initiative of computerization of blood products traceability within regional blood banks and public and private hospitals. The Auvergne-Loire Regional French Blood Service, based in Saint-Etienne, together with a number of public hospitals set up a transfusion data network named EDITAL. After four years of progressive implementation and experimentation, a software enabling standardized data exchange has built up a regional nominative database, endorsed by the Traceability Computerization National Committee in 2004. This database now provides secured web access to a regional transfusion history enabling biologists and all hospital and family practitioners to take in charge the patient follow-up. By running independently from the softwares of its partners, EDITAL database provides reference for the regional identity server.

  8. CEOS SEO and GISS Meeting

    NASA Technical Reports Server (NTRS)

    Killough, Brian; Stover, Shelley

    2008-01-01

    The Committee on Earth Observation Satellites (CEOS) provides a brief to the Goddard Institute for Space Studies (GISS) regarding the CEOS Systems Engineering Office (SEO) and current work on climate requirements and analysis. A "system framework" is provided for the Global Earth Observation System of Systems (GEOSS). SEO climate-related tasks are outlined including the assessment of essential climate variable (ECV) parameters, use of the "systems framework" to determine relevant informational products and science models and the performance of assessments and gap analyses of measurements and missions for each ECV. Climate requirements, including instruments and missions, measurements, knowledge and models, and decision makers, are also outlined. These requirements would establish traceability from instruments to products and services allowing for benefit evaluation of instruments and measurements. Additionally, traceable climate requirements would provide a better understanding of global climate models.

  9. Modeling connected and autonomous vehicles in heterogeneous traffic flow

    NASA Astrophysics Data System (ADS)

    Ye, Lanhang; Yamamoto, Toshiyuki

    2018-01-01

    The objective of this study was to develop a heterogeneous traffic-flow model to study the possible impact of connected and autonomous vehicles (CAVs) on the traffic flow. Based on a recently proposed two-state safe-speed model (TSM), a two-lane cellular automaton (CA) model was developed, wherein both the CAVs and conventional vehicles were incorporated in the heterogeneous traffic flow. In particular, operation rules for CAVs are established considering the new characteristics of this emerging technology, including autonomous driving through the adaptive cruise control and inter-vehicle connection via short-range communication. Simulations were conducted under various CAV-penetration rates in the heterogeneous flow. The impact of CAVs on the road capacity was numerically investigated. The simulation results indicate that the road capacity increases with an increase in the CAV-penetration rate within the heterogeneous flow. Up to a CAV-penetration rate of 30%, the road capacity increases gradually; the effect of the difference in the CAV capability on the growth rate is insignificant. When the CAV-penetration rate exceeds 30%, the growth rate is largely decided by the capability of the CAV. The greater the capability, the higher the road-capacity growth rate. The relationship between the CAV-penetration rate and the road capacity is numerically analyzed, providing some insights into the possible impact of the CAVs on traffic systems.

  10. Data Synthesis and Data Assimilation at Global Change Experiments and Fluxnet Toward Improving Land Process Models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luo, Yiqi

    The project was conducted during the period from 7/1/2012 to 6/30/2017 with three major tasks: (1) data synthesis and development of data assimilation (DA) techniques to constrain modeled ecosystem feedback to climate change; (2) applications of DA techniques to improve process models at different scales from ecosystem to regions and the globe; and 3) improvements of modeling soil carbon (C) dynamics by land surface models. During this period, we have synthesized published data from soil incubation experiments (e.g., Chen et al., 2016; Xu et al., 2016; Feng et al., 2016), global change experiments (e.g., Li et al., 2013; Shi etmore » al., 2015, 2016; Liang et al., 2016) and fluxnet (e.g., Niu et al., 2012., Xia et al., 2015; Li et al., 2016). These data have been organized into multiple data products and have been used to identify general mechanisms and estimate parameters for model improvement. We used the data sets that we collected and the DA techniques to improve model performance of both ecosystem models and global land models. The objectives are: 1) to improve model simulations of litter and soil carbon storage (e.g., Schädel et al., 2013; Hararuk and Luo, 2014; Hararuk et al., 2014; Liang et al., 2015); 2) to explore the effects of CO 2, warming and precipitation on ecosystem processes (e.g., van Groenigen et al., 2014; Shi et al., 2015, 2016; Feng et al., 2017); and 3) to estimate parameters variability in different ecosystems (e.g., Li et al., 2016). We developed a traceability framework, which was based on matrix approaches and decomposed the modeled steady-state terrestrial ecosystem carbon storage capacity into four can trace the difference in ecosystem carbon storage capacity among different biomes to four traceable components: net primary productivity (NPP), baseline C residence times, environmental scalars and climate forcing (Xia et al., 2013). With this framework, we can diagnose the differences in modeled carbon storage across ecosystems, biomes, and models. This framework has been successfully implemented by several global land models, such as CABLE (Xia et al., 2013), LPJ-GUESS (Ahlström et al., 2015), CLM (Hararuk et al., 2014; Huang et al., 2017, submitted; Shi et al., 2017, submitted), and ORCHIDEE (Huang et al., 2017, unpublished). Moreover, we have identified the theoretical foundation of the determinants of transient C storage dynamics by adding another term, C storage potential, to the steady-state traceability framework (Luo et al., 2017). The theoretical foundation of transient C storage dynamics has been applied to develop a transient traceability framework to explore the traceable components of transient C storage dynamics responded to the rising CO 2 and climate change in the two contrasting ecosystem types Duke needleleaved forest and Harvard deciduous broadleaved forest (Jiang et al., 2017, in revision). Overall, with the data synthesis, data assimilation techniques, and the steady-state and transient traceability frameworks, we have greatly improved land process models for predicting responses and feedback of terrestrial C dynamics to global change. The matrix approaches has the potential to be applied in theoretical research on nitrogen and phosphorus cycle, and therefore, the coupling of carbon-nitrogen-phosphorus.« less

  11. Architecture for improved mass transport and system performance in redox flow batteries

    NASA Astrophysics Data System (ADS)

    Houser, Jacob; Pezeshki, Alan; Clement, Jason T.; Aaron, Douglas; Mench, Matthew M.

    2017-05-01

    In this work, electrochemical performance and parasitic losses are combined in an overall system-level efficiency metric for a high performance, all-vanadium redox flow battery. It was found that pressure drop and parasitic pumping losses are relatively negligible for high performance cells, i.e., those capable of operating at a high current density while at a low flow rate. Through this finding, the Equal Path Length (EPL) flow field architecture was proposed and evaluated. This design has superior mass transport characteristics in comparison with the standard serpentine and interdigitated designs at the expense of increased pressure drop. An Aspect Ratio (AR) design is discussed and evaluated, which demonstrates decreased pressure drop compared to the EPL design, while maintaining similar electrochemical performance under most conditions. This AR design is capable of leading to improved system energy efficiency for flow batteries of all chemistries.

  12. A knowledge-based approach to automated flow-field zoning for computational fluid dynamics

    NASA Technical Reports Server (NTRS)

    Vogel, Alison Andrews

    1989-01-01

    An automated three-dimensional zonal grid generation capability for computational fluid dynamics is shown through the development of a demonstration computer program capable of automatically zoning the flow field of representative two-dimensional (2-D) aerodynamic configurations. The applicability of a knowledge-based programming approach to the domain of flow-field zoning is examined. Several aspects of flow-field zoning make the application of knowledge-based techniques challenging: the need for perceptual information, the role of individual bias in the design and evaluation of zonings, and the fact that the zoning process is modeled as a constructive, design-type task (for which there are relatively few examples of successful knowledge-based systems in any domain). Engineering solutions to the problems arising from these aspects are developed, and a demonstration system is implemented which can design, generate, and output flow-field zonings for representative 2-D aerodynamic configurations.

  13. High-Performance Algorithms and Complex Fluids | Computational Science |

    Science.gov Websites

    only possible by combining experimental data with simulation. Capabilities Capabilities include: Block -laden, non-Newtonian, as well as traditional internal and external flows. Contact Ray Grout Group

  14. Proceedings of the August 2011 Traceability Research Summit.

    PubMed

    Bhatt, Tejas; Buckley, Greg; McEntire, Jennifer C

    2013-12-01

    IFT's Traceability Improvement Initiative aims to advance work in the area of food product tracing through several means including hosted events where thought leaders exchange knowledge and ideas. In August 2011, the Initiative, in collaboration with GS1 US, convened a group of 50 product tracing stakeholders, as a follow-on to a successful event the month prior. Representatives conducting pilots or implementation studies in produce, seafood, dairy, and other industries discussed the objectives, challenges and learnings. Some of the learnings from on-going initiatives included the sense that better information management provides a return of investment; data often exist but may not necessarily be appropriately linked through the supply chain; and enhanced product tracing enables better accountability and quality control. Challenges identified in enabling traceability throughout the supply chain were the distribution complexity; the need for training, communication, and collaboration; improving the reliability, quality and security of data captured, stored and shared as well as the importance of standards in data and interoperability of technology. Several approaches to overcoming these challenges were discussed. The first approach incrementally improves upon the current "one up/one down" system by requiring electronic records and tracking internal as well as external critical tracking events. The benefits of this approach are its similarity to existing regulatory requirements and low cost of implementation; resulting in a higher probability of adoption. The major disadvantage to this process is the longer response time required during a trace (back or forward). The second approach is similar to a "pedigree" approach where historical information about the food travels with it through the value chain. A major advantage of this approach is the quickest response time during a trace. Some of the disadvantages of this approach are potential for misuse of data, the volume of data required to be maintained at value chain end points, and data privacy concerns. The third approach requires individual nodes within the value chain to maintain electronic records for its own data and make them available for querying during a traceback for outbreak investigation. The major advantage of this approach is the protection of confidential information and the potential for quicker access during a trace. However, the primary disadvantage of this approach is the need for greater computational power and a more complex mechanism to linking the value chain through the data. As next steps, a subgroup will work on clarifying the approach to meeting the goals of traceability, better defining critical tracking events, and articulating the strategy and return on investment from a regulatory and industry perspective. This will result in improved alignment of on-going traceability pilots and initiatives as well as a more actionable guidance document for public review. © 2012 Institute of Food Technologists®

  15. Reversing flow causes passive shark scale actuation in a separating turbulent boundary layer

    NASA Astrophysics Data System (ADS)

    Lang, Amy; Gemmell, Bradford; Motta, Phil; Habegger, Laura; Du Clos, Kevin; Devey, Sean; Stanley, Caleb; Santos, Leo

    2017-11-01

    Control of flow separation by shortfin mako skin in experiments has been demonstrated, but the mechanism is still poorly understood yet must be to some extent Re independent. The hypothesized mechanisms inherent in the shark skin for controlling flow separation are: (1) the scales, which are capable of being bristled only by reversing flow, inhibit flow reversal events from further development into larger-scale separation and (2) the cavities formed when scales bristle induces mixing of high momentum flow towards the wall thus energizing the flow close to the surface. Two studies were carried out to measure passive scale actuation caused by reversing flow. A small flow channel induced an unsteady, wake flow over the scales prompting reversing flow events and scale actuation. To resolve the flow and scale movements simultaneously we used specialized optics at high magnification (1 mm field of view) at 50,000 fps. In another study, 3D printed models of shark scales, or microflaps (bristling capability up to 50 degrees), were set into a flat plate. Using a tripped, turbulent boundary layer grown over the long flat plate and a localized adverse pressure gradient, a separation bubble was generated within which the microflaps were placed. Passive flow actuation of both shark scales and microflaps by reversing flow was observed. Funding from Army Research Office and NSF REU site Grant.

  16. 40 CFR 35.1605-4 - Nonpoint source.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Lakes § 35.1605-4 Nonpoint source. Pollution sources which generally are not controlled by establishing... traceable to a discrete identifiable origin, but generally result from land runoff, precipitation, drainage...

  17. Drag measurements on a laminar-flow body of revolution in the 13-inch magnetic suspension and balance system

    NASA Technical Reports Server (NTRS)

    Dress, David A.

    1989-01-01

    Low speed wind tunnel drag force measurements were taken on a laminar flow body of revolution free of support interference. This body was tested at zero incidence in the NASA Langley 13 in. Magnetic Suspension and Balance System (MSBS). The primary objective of these tests was to substantiate the drag force measuring capabilities of the 13 in. MSBS. The drag force calibrations and wind-on repeatability data provide a means of assessing these capabilities. Additional investigations include: (1) the effects of fixing transition; (2) the effects of fins installed in the tail; and (3) surface flow visualization using both liquid crystals and oil flow. Also two simple drag prediction codes were used to assess their usefulness in estimating overall body drag.

  18. Sagnac-interferometer-based fresnel flow probe.

    PubMed

    Tselikov, A; Blake, J

    1998-10-01

    We used a near-diffraction-limited flow or light-wave-interaction pipe to produce a Sagnac-interferometer-based Fresnel drag fluid flowmeter capable of detecting extremely small flow rates. An optimized design of the pipe along with the use of a state-of-the-art Sagnac interferometer results in a minimum-detectable water flow rate of 2.4 nl/s [1 drop/(5 h)]. The flowmeter's capability of measuring the water consumption by a small plant in real time has been demonstrated. We then designed an automated alignment system that finds and maintains the optimum fiber-coupling regime, which makes the applications of the Fresnel-drag-based flowmeters practical, especially if the length of the interaction pipe is long. Finally, we have applied the automatic alignment technique to an air flowmeter.

  19. Contact and Impact Dynamic Modeling Capabilities of LS-DYNA for Fluid-Structure Interaction Problems

    DTIC Science & Technology

    2010-12-02

    rigid sphere in a vertical water entry,” Applied Ocean Research, 13(1), pp. 43-48. Monaghan, J.J., 1994. “ Simulating free surface flows with SPH ...The kinematic free surface condition was used to determine the intersection between the free surface and the body in the outer flow domain...and the results were compared with analytical and numerical predictions. The predictive capability of ALE and SPH features of LS-DYNA for simulation

  20. Air elimination capability in rapid infusion systems.

    PubMed

    Zoremba, N; Gruenewald, C; Zoremba, M; Rossaint, R; Schaelte, G

    2011-11-01

    Pressure infusion devices are used in clinical practice to apply large volumes of fluid over a short period of time. Although air infusion is a major complication, they have limited capability to detect and remove air during pressure infusion. In this investigation, we tested the air elimination capabilities of the Fluido(®) (The Surgical Company), Level 1(®) (Level 1 Technologies Inc.) and Ranger(®) (Augustine Medical GmbH) pressure infusion devices. Measurements were undertaken with a crystalloid solution during an infusion flow of 100, 200, 400 and 800 ml.min(-1). Four different volumes of air (25, 50, 100 and 200 ml) were injected as boluses in one experimental setting, or infused continuously over the time needed to perfuse 2 l saline in the other setting. The perfusion fluid was collected in an airtight infusion bag and the amount of air obtained in the bag was measured. The delivered air volume was negligible and would not cause any significant air embolism in all experiments. In our experimental setting, we found, during high flow, an increased amount of uneliminated air in all used devices compared with lower perfusion flows. All tested devices had a good air elimination capability. The use of ultrasonic air detection coupled with an automatic shutoff is a significant safety improvement and can reliably prevent accidental air embolism at rapid flows. © 2011 The Authors. Anaesthesia © 2011 The Association of Anaesthetists of Great Britain and Ireland.

Top