Kim, Hee Jin; Lee, Tae Won; Ihm, Chun Gyoo; Kim, Myung Jae
2002-01-01
Peritoneal catheter is the lifeline for the continuous ambulatory peritoneal dialysis (CAPD) patients. Over the years, obstruction or displacement of the CAPD catheter has been one of the common complications of CAPD. Fluoroscopy-guided wire manipulation or laparoscopic surgery has been developed to manage outflow obstruction. We analyzed the catheter outcome of fluoroscopy-guided wire manipulation or laparoscopic surgery to determine the ultimate benefit of these procedures. From June 1996 to August 2000, catheter complications were manipulated in 24 patients. Eleven (46%) of these patients were initially managed by guide wire under fluoroscopic control. The remaining 13 (54%) patients were manipulated by laparoscopic surgery. A successful outcome was defined as maintained normal peritoneal catheter function at 30 days after the manipulations. Among the catheters manipulated, 18 (75%) were inserted by nephrologist and 6 (25%) by surgeons at the initiation of CAPD. Tenckhoff double-cuff peritoneal catheters were inserted to all patients. The time elapsed between catheter insertion and manipulation varied from 1 to 60 days with a mean of 11 days. The primary causes of catheter malfunction were kinking in 1 case, omental wrapping with adhesions in 9 cases, and catheter displacements in the remaining 14 cases. Thirty-day catheter function was achieved in 50% (12/24) of initial catheter manipulations, with guide wire under fluoroscopic control (46%, 5/11) and laparoscopic surgery (54%, 7/13). Overall success rate of repeated manipulation was 71% (17 of 24). The successful outcome in repairing of the malfunctioning CAPD catheters could be increased by the combination of fluoroscopy-guided wire manipulation and laparoscopic surgery. Copyright 2002 S. Karger AG, Basel
Wearne, Nicola; Kilonzo, Kajiru; Effa, Emmanuel; Davidson, Bianca; Nourse, Peter; Ekrikpo, Udeme; Okpechi, Ikechi G
2017-01-01
Chronic kidney disease is a major public health problem that continues to show an unrelenting global increase in prevalence. The prevalence of chronic kidney disease has been predicted to grow the fastest in low- to middle-income countries (LMICs). There is evidence that people living in LMICs have the highest need for renal replacement therapy (RRT) despite the lowest access to various modalities of treatment. As continuous ambulatory peritoneal dialysis (CAPD) does not require advanced technologies, much infrastructure, or need for dialysis staff support, it should be an ideal form of RRT in LMICs, particularly for those living in remote areas. However, CAPD is scarcely available in many LMICs, and even where available, there are several hurdles to be confronted regarding patient selection for this modality. High cost of CAPD due to unavailability of fluids, low patient education and motivation, low remuneration for nephrologists, lack of expertise/experience for catheter insertion and management of complications, presence of associated comorbid diseases, and various socio-demographic factors contribute significantly toward reduced patient selection for CAPD. Cost of CAPD fluids seems to be a major constraint given that many countries do not have the capacity to manufacture fluids but instead rely heavily on fluids imported from developed countries. There is need to invest in fluid manufacturing (either nationally or regionally) in LMICs to improve uptake of patients treated with CAPD. Workforce training and retraining will be necessary to ensure that there is coordination of CAPD programs and increase the use of protocols designed to improve CAPD outcomes such as insertion of catheters, treatment of peritonitis, and treatment of complications associated with CAPD. Training of nephrology workforce in CAPD will increase workforce experience and make CAPD a more acceptable RRT modality with improved outcomes. PMID:28115864
Nakamura-Taira, Nanako; Muranaka, Yoshimi; Miwa, Masako; Kin, Seikon; Hirai, Kei
2013-08-01
The preference for dialysis modalities is not well understood in Japan. This study explored the subjective views of Japanese patients undergoing dialysis regarding their treatments. The participants were receiving in-center hemodialysis (CHD) or continuous ambulatory peritoneal dialysis (CAPD). In Study 1, 34 participants (17 CHD and 17 CAPD) were interviewed about the advantages and disadvantages of dialysis modalities. In Study 2, 454 dialysis patients (437 CHD and 17 CAPD) rated the advantages and disadvantages of CHD and CAPD in a cross-sectional survey. Interviews showed that professional care and dialysis-free days were considered as advantages of CHD, while independence, less hospital visits, and flexibility were considered as advantages of CAPD. Disadvantages of CHD included restriction of food and fluids and unpleasant symptoms after each dialysis session. Catheter care was an additional disadvantage of CAPD. Survey showed that the highly ranked advantages were professional care in CHD and less frequent hospital visits in CAPD, while the highly ranked disadvantages were concerns about emergency and time restrictions in CHD, and catheter care and difficulty in soaking in a bath in CAPD. The total scores of advantages and disadvantages showed that CHD patients subjectively rated their own modality better CHD over CAPD, while CAPD patients had the opposite opinion. The results of this study indicate that the factors affecting the decision-making process of Japanese patients are unique to Japanese culture, namely considering the trouble caused to the people around patients (e.g., families, spouses, and/or caregivers).
[Anatomical and clinical evaluation regarding the removal of the peritoneal dialysis catheter].
Tăranu, T; Covic, A; Târcoveanu, E; Florea, Laura
2005-01-01
To describe CAPD technique survival and causes for catheter removal. The study included 320 end stage renal disease (ESRD) patients, initiated on CAPD between 1995-2003. Definitive catheter removal was required in 44 cases (15.1%), 11 of these (3.79%) receiving renal transplant. Causes for catheter removal were: mechanical obstruction by fibrin (8 cases/2.75%), obstruction by tub bower (1 case/0.34%), by omental muff (6 cases/2%); abdominal wall sepsis (30 cases/ 10.3%); non-responsive bacterial peritonitis (13 cases/4.05%), fungal peritonitis (7 cases/ 2.4%), fecal peritonitis (2 cases/0.68%); transfer to hemodialysis program (31 cases/10.6%); renal transplant (11 cases/3.79%); emergency surgical pathology for: necrotic-hemorrhagic pancreatitis (two cases), intestinal occlusions (six cases), locked hernias (three cases) and locked eventrations(three cases), appendicular peritonitis (two cases). Mortality associated with these procedures and underlying pathology was 1.73%.
Ndlovu, Kwazi C Z; Sibanda, Wilbert; Assounga, Alain
2017-02-03
Few studies have investigated the management of human immunodeficiency virus (HIV)-associated end-stage renal failure particularly in low-resource settings with limited access to renal replacement therapy. We aimed to evaluate the effects of HIV infection on continuous ambulatory peritoneal dialysis (CAPD)-associated peritonitis outcomes and technique failure in highly active antiretroviral therapy (HAART)-treated HIV-positive CAPD populations. We conducted a single-center prospective cohort study of consecutive incident CAPD patients recruited from two hospitals in Durban, South Africa from September 2012-February 2015. Seventy HIV-negative and 70 HIV-positive end-stage renal failure patients were followed monthly for 18 months at a central renal clinic. Primary outcomes of peritonitis and catheter failure were assessed for the first 18 months of CAPD therapy. We assessed risk factors for peritonitis and catheter failure using Cox regression survival analysis. The HIV-positive cohort had a significantly increased rate of peritonitis compared to the HIV-negative cohort (1.86 vs. 0.76 episodes/person-years, respectively; hazard ratio [HR], 2.41; 95% confidence interval [CI], 1.69-3.45, P < 0.001). When the baseline CD4 count was below 200 cells/μL, the peritonitis rate rose to 3.69 episodes/person-years (HR 4.54, 95% CI 2.35-8.76, P < 0.001), while a baseline CD4 count above 350 cells/μL was associated with a peritonitis rate of 1.60 episodes/person-years (HR 2.10, CI 1.39-3.15, P = 0.001). HIV was associated with increased hazards of peritonitis relapse (HR, 3.88; CI, 1.37-10.94; P = 0.010). Independent predictors associated with increased peritonitis risk were HIV (HR, 1.84; CI, 1.07-3.16; P = 0.027), diabetes (HR, 2.09; CI, 1.09-4.03; P = 0.027) and a baseline CD4 count < 200 cells/μL (HR, 3.28; CI, 1.42-7.61; P = 0.006). Catheter failure rates were 0.34 (HIV-positive cohort) and 0.24 (HIV-negative cohort) episodes/person-years (HR, 1.42; 95% CI, 0.73-2.73; P = 0.299). Peritonitis (HR, 14.47; CI, 2.79-75.00; P = 0.001), average hemoglobin concentrations (HR, 0.75; CI, 0.59-0.95; P = 0.016), and average serum C-reactive protein levels were independent predictors of catheter failure. HIV infection in end-stage renal disease patients managed by CAPD was associated with increased peritonitis risk; however, HIV infection did not increase the risk for CAPD catheter failure rate at 18 months.
Tamaki, Masafumi; Ikeda, Mayumi; Norimura, Naoko; Miura, Kazumasa; Yoshizawa, Kiyoshi
2012-02-01
A 61-year-old female was diagnosed as having end-stage renal failure developed dyspnea soon after introduction of continuous ambulatory peritoneal dialysis (CAPD). Chest X-ray showed a right-side massive pleural effusion. Pleuro peritoneal communication was suspicious, because the hydrothorax significantly improved by the stop of CAPD. We performed video-assisted thoracic surgery. Using indigo carmine containing peritoneal dialysis fluid through a CAPD catheter, we found a fistula on the diaphragm from which blue dialysis solution flowed out like a fountain. The fistula of the diaphragm was directly closed with a surgical stapler and covered using cellulose oxidized (Surgicel) and fibrin glue. She could restart CAPD on postoperative days 7, and no recurrence of hydrothorax has been detected for 10 months after surgical treatment.
El-Reshaid, Wael; Al-Disawy, Hanan; Nassef, Hossameldeen; Alhelaly, Usama
2016-09-01
Peritonitis is a common complication in patients undergoing continuous ambulatory peritoneal dialysis (CAPD) and automated peritoneal dialysis (APD). In this retrospective study, peritonitis rates and patient survival of 180 patients on CAPD and 128 patients on APD were compared in the period from January 2005 to December 2014 at Al-Nafisi Center in Kuwait. All patients had prophylactic topical mupirocin at catheter exit site. Patients on CAPD had twin bag system with Y transfer set. The peritonitis rates were 1 in 29 months in CAPD and 1 in 38 months in APD (p < 0.05). Percentage of peritonitis free patients over 10-year period in CAPD and APD were 49 and 60%, respectively (p < 0.05). Time to develop peritonitis was 10.25 ± 3.1 months in CAPD compared to 16.1 ± 4 months in APD (p < 0.001). Relapse and recurrence rates were similar in both groups. Median patient survival in CAPD and APD groups with peritonitis was 13.1 ± 1 and 14 ± 1.4 months respectively (p = 0.3) whereas in peritonitis free patients it was 15 ± 1.4 months in CAPD and 23 ± 3.1 months in APD (p = 0.025). APD had lower incidence rate of peritonitis than CAPD. Patient survival was better in APD than CAPD in peritonitis free patients but was similar in patients who had peritonitis.
van Laanen, Jorinde H H; Cornelis, Tom; Mees, Barend M; Litjens, Elisabeth J; van Loon, Magda M; Tordoir, Jan H M; Peppelenbosch, Arnoud G
2018-01-01
To determine the best operation technique, open versus laparoscopic, for insertion of a peritoneal dialysis (PD) catheter with regard to clinical success. Clinical success was defined as an adequate function of the catheter 2 - 4 weeks after insertion. All patients with end-stage renal disease who were suitable for PD and gave informed consent were randomized for either open surgery or laparoscopic surgery. A previous laparotomy was not considered an exclusion criterion. Laparoscopic placement had the advantage of pre-peritoneal tunneling, the possibility for adhesiolysis, and placement of the catheter under direct vision. Catheter fixation techniques, omentopexy, or other adjunct procedures were not performed. Other measured parameters were in-hospital morbidity and mortality and post-operative infections. Between 2010 and 2016, 95 patients were randomized to this study protocol. After exclusion of 5 patients for various reasons, 44 patients received an open procedure and 46 patients a laparoscopic procedure. Gender, age, body mass index (BMI), hypertension, current hemodialysis, severe heart failure, and previous an abdominal operation were not significantly different between the groups. However, in the open surgery group, fewer patients had a previous median laparotomy compared with the laparoscopic group (6 vs 16 patients; p = 0.027). There was no statistically significant difference in mean operation time (36 ± 24 vs 38 ± 15 minutes) and hospital stay (2.1 ± 2.7 vs 3.1 ± 7.3 days) between the groups. In the open surgery group 77% of the patients had an adequate functioning catheter 2 - 4 weeks after insertion compared with 70% of patients in the laparoscopic group ( p = not significant [NS]). In the open surgery group there was 1 post-operative death (2%) compared with none in the laparoscopic group ( p = NS). The morbidity in both groups was low and not significantly different. In the open surgery group, 2 patients had an exit-site infection and 1 patient had a paramedian wound infection. In the laparoscopic group, 1 patient had a transient cardiac event, 1 patient had intraabdominal bleeding requiring reoperation, and 1 patient had fluid leakage that could be managed conservatively. The survival curve demonstrated a good long-term function of PD. This randomized controlled trial (RCT) comparing open vs laparoscopic placement of PD catheters demonstrates equal clinical success rates between the 2 techniques. Advanced laparoscopic techniques such as catheter fixation techniques and omentopexy might further improve clinical outcome. Copyright © 2018 International Society for Peritoneal Dialysis.
Continuous Ambulatory Peritoneal Dialysis in Patients with HIV and End-Stage Renal Failure.
Ndlovu, Kwazi C Z; Assounga, Alain
2017-01-01
♦ BACKGROUND: This study aimed to evaluate the differences in continuous ambulatory peritoneal dialysis (CAPD)-related outcomes according to human immunodeficiency virus (HIV) status of end-stage renal failure patients. ♦ METHODS: This prospective cohort study included 70 HIV-negative and 70 HIV-positive consecutive patients with renal failure who underwent dialysis with newly inserted Tenckhoff catheters between September 2012 and February 2015. Patients were followed up monthly at a central renal clinic for 1 year or until the primary endpoints of technique failure or death. ♦ RESULTS: Technique failure rates were similar (HIV-negative: 0.270 episodes/person-year; HIV-positive: 0.298 episodes/person-year; hazard ratio [HR], 1.09; 95% confidence interval [CI], 0.51 - 2.32; p = 0.822). However, there were fewer HIV-positive patients with complete 1-year follow-up with a patent catheter (42.9% vs 58.6% in the HIV-negative cohort; p = 0.063) owing to their higher all-cause mortality rate (0.55 vs 0.25 deaths/person-year, respectively; HR, 2.11; CI, 1.07 - 4.14; p = 0.031). Cluster of differentiation 4 count (CD4) < 200/μL (HR, 5.39; CI, 2.20 - 13.21; p < 0.001) and unsuppressed viral load (HR, 3.63; CI 1.72 - 7.67; p = 0.001) were associated with increased mortality hazards. Rates of first peritonitis were 0.616 (HIV-negative) and 1.668 (HIV-positive) episodes/person-year (HR, 2.38; CI, 1.46 - 3.89; p = 0.001). All-cause admission rates were 1.52 (HIV-negative) and 2.97 (HIV-positive) hospital admissions/person-year (HR, 1.66; CI, 1.12 - 2.48; p = 0.013). ♦ CONCLUSION: Although HIV-seropositive status of patients on CAPD did not adversely influence technique failure rates or patency at 1 year, uncontrolled HIV infection may be associated with increased relative risk of mortality and morbidity. Copyright © 2017 International Society for Peritoneal Dialysis.
Peritoneal dialysis technique success during the initial 90 days of therapy.
Guest, Steven; Hayes, Andrew C; Story, Kenneth; Davis, Ira D
2012-01-01
Comparisons of technique success by peritoneal dialysis (PD) modality have typically excluded the initial 90 days of therapy. We analyzed a database of 51,469 new PD starts from 2004 to 2008 in the United States. The analysis concentrated on the initial 90 days of therapy to determine technique success and the impact of the continuous ambulatory PD (CAPD) and automated PD (APD) modalities. Overall, 13.3% of patients stopped PD within 90 days. Of patients starting directly on APD, 14.3% stopped PD within 90 days. Of patients starting on CAPD, 12.6% stopped PD within 90 days, and 63.4% changed to APD within 90 days. Only 3.3% of the latter patients failed to reach 90 days of therapy. By comparison, technique failure occurred in 28.8% of those initiating with and remaining on CAPD. We conclude that initial training to perform CAPD, with timely transfer to APD within the first 3 months, was associated with the greatest technique success at 90 days. The reasons for that success are unclear, and further research should be directed to determining factors responsible. It is possible that patients trained initially to CAPD but converted to APD have a greater understanding of the total therapy, which improves confidence. Those converted to APD may be more appreciative of the lifestyle benefits of APD, which translates into improved compliance; alternatively, technical factors associated with APD may be responsible. Those technical factors may include improved catheter function in the recumbent position during APD or the reduced infection risk associated with just 2 connect/disconnect procedures in APD compared with 8 in CAPD.
Definitions of differences and changes in peritoneal membrane water transport properties.
Widerøe, T E; Smeby, L C; Dahl, K; Jörstad, S
1988-06-01
A survey is given comparing measurements of transperitoneal water transport in different clinical situations with analyses based on the so-called "pore theory." This model links the measured changes to physical alterations of the peritoneal membrane. The calculations include "equivalent pore radius," effective "membrane area" and diffusive length, the transport resistance of the unstirred dialysate layer, and the residual intraperitoneal volume after dialysate drainage. The clinical appearances include individual differences in transperitoneal transport characteristics, changes in transperitoneal transport over time on continuous ambulatory peritoneal dialysis (CAPD) and during peritonitis, the pharmacological effect on the transport properties, and the effect of peritoneal catheter dislocation on ultrafiltration capacity. The main conclusions are as follow: During CAPD treatment the measurement of intraperitoneal solute equilibration and "mass-transfer-area coefficients" for urea and creatinine is less sensitive than the measurement of ultrafiltration volume in revealing peritoneal membrane changes. Differences and changes found have mostly a combined physical explanation, but one is more or less dominant. Changes in peritoneal membrane area seem to be the most dominant cause of changes in transperitoneal transport during time on CAPD and when sodium nitroprusside was added to the peritoneal dialysate. Changes during peritonitis can be explained by changes in pore radius and depth. Individual differences can be explained by differences in "membrane" area and in resistance of the unstirred dialysate fluid. High residual dialysate volume can give rise to clinical problems and should be considered when placing the catheter in the peritoneal cavity.
Favazza, A; Petri, R; Montanaro, D; Boscutti, G; Bresadola, F; Mioni, G
1995-01-01
This study describes the results of the insertion of a straight Tenckhoff peritoneal catheter (PC) in an arcuate, caudally concave tunnel using a tunneler designed by the authors. It has a semicircular shape and a bending radius of 4.5 cm. A hospital renal unit. From June 1988 to February 1994, 112 straight Tenckhoff PCs, 62 with one deep cuff (single-cuff PC) and 50 with two cuffs (double-cuff PC), were inserted as first catheters in 112 patients (mean age 62 +/- 13 years), who underwent continuous ambulatory peritoneal dialysis (CAPD). The follow-up was 1099 months (mean 18 +/- 13 months) for single-cuff PCs and 1264 months (mean 25 +/- 15 months) for double-cuff PCs, respectively. After intraperitoneal placement of the PCs by median laparotomy, a 180 degrees arc bend tunnel, with both external and peritoneal exits directed downwards, was created by means of the tunneler. The rate of exit-site infection (ESI) was 0.27 episodes/year (epis/year). The probability of remaining ESI-free was 76%, 60%, and 55% at 1, 2, and 3 years. The rate of tunnel infection (TI) was 0.046 epis/year. The incidence of the double-cuff PC-related ESI and TI tended to be lower than the incidence observed with the single-cuff PC. Episodes of peritonitis were 60 (0.30 epis/year), where 6 were subsequent to ESI and/or TI. Two PCs were lost due to ESI, 3 due to TI, and 11 due to peritonitis. Drainage failure, due to displacement of the PC caused by straightening, involved 3 PCs; 2 were lost. PC survival was 92%, 82%, and 74% at 1, 2 and 3 years, respectively. By an easily used semicircular tunneler, the standard straight Tenckhoff PC can be stably positioned in an arcuate tunnel with both inner and outer exits directed downwards. This tunnel shape, as already suggested by some authors, appears to be an effective technical solution to reducing the PC-related complication rates.
Ramanathan, Kumaresan; Padmanabhan, Giri; Vijayaraghavan, Bhooma
2016-05-01
Severe peritonitis causing death is one of the most devastating complications of peritoneal dialysis (PD). Since the predictive value of C-reactive protein (CRP) in PD fluid has not been assessed, the objective of the present study is to evaluate its predictive value and clinical correlation in patients on PD with peritonitis. One hundred and twenty patients on continuous ambulatory PD (CAPD) were enrolled and their serum and fluid CRP (Fl. CRP) were evaluated at the start of CAPD. All patients who developed peritonitis were further evaluated for serum and fluid CRP. The patients were categorized into four groups, namely: normal patients (control group), patients with peritonitis, patients with peritonitis leading to catheter removal, and death due to peritonitis. Sixty-five patients developed peritonitis of whom, catheter removal was performed in eight patients. Five patients died due to peritonitis-related complications. Fl. CRP showed a significant difference among the three groups, unlike S. CRP. Estimation of CRP in the peritoneal fluid may be a useful marker to monitor the onset of peritonitis.
Non Candida albicans fungal peritonitis in continuous ambulatory peritoneal dialysis patients.
Kleinpeter, M A; Butt, A A
2001-01-01
We report four episodes of non Candida albicans peritonitis (NCAP) in 3 patients on continuous ambulatory peritoneal dialysis (CAPD). Risk factors for NCAP included diabetes mellitus and prior antibiotic use in half of the cases. The antibiotic treatment was prescribed for exit-site infection (ESI) or peritonitis in the patient. Treatment for NCAP included antifungal therapy with oral fluconazole or intravenous amphotericin B. The NCAP resulted in catheter loss in 100% of the patients over time. Initial catheter salvage in one patient was followed 6 months later by catheter loss following treatment of a bacterial peritonitis that was complicated by the development of Candida (Torulopsis) glabrata peritonitis unresponsive to treatment with intravenous amphotericin B. Although the literature suggests that Candida peritonitis responds to oral fluconazole with and without catheter removal, this series suggests that the treatment of NCAP includes removal of the peritoneal dialysis catheter with appropriate antifungal agents.
Aoyama, Masato; Mizuno, Toshihide; Tatsumi, Eisuke; Taenaka, Yoshiyuki; Nemoto, Yasushi; Okamoto, Yoshihiro; Takemoto, Yoshiaki; Naganuma, Toshihide; Nakatani, Tatsuya
2009-12-01
Because currently available peritoneal dialysis catheters are not sufficiently biocompatible with the skin and subcutaneous tissue at the site of penetration, exit-site infection due to pericatheter pocket formation caused by epidermal downgrowth over a long period of time has increasingly become a problem. We developed a new, biocompatible, segmented polyurethane porous material and devised a novel skin-penetrating pad, the form and material of which we optimized for application in peritoneal dialysis catheters. For the extent of tissue ingrowth into this porous material to be examined, test materials with different pore diameters were inserted into hollow silicone tubes and implanted in the subcutaneous tissue of a goat. Four weeks later, the tubes were extracted, and, after the extent of granulation tissue ingrowth was measured, histopathological evaluation was made. Our novel skin-penetrating pad has three disklike layers of the segmented polyurethane material with different pore sizes, into the center of which a polyurethane catheter is inserted. These pads were implanted in the skin of a goat and clinically observed over a 2-year period, after which they were extracted and histopathologically analyzed. In accordance with actual clinical procedures, a commercial CAPD catheter equipped with our skin-penetrating pad was left indwelling in a goat for 4 months, and the performance of the pad was evaluated after repeated periodic infusion and drainage of the dialysate in and out of the abdominal cavity. There was no inflammation of the ingrown tissue in the pores of the segmented polyurethane material as well as the surrounding tissue, which indicated favorable tissue biocompatibility. The extent of tissue ingrowth was greater as the pore size of the material was larger, and the tissue tended to be mature, mainly consisting of collagenous fibers. The skin-penetrating pad using the porous material, of which tissue ingrowth was thus optimized, tightly adhered to the goat skin throughout the 2-year experimental period without any special wound care such as cleansing or disinfection. The performance of the skin-penetrating pad was similarly favorable when attached to a commercial continuous ambulatory peritoneal dialysis catheter. The newly developed segmented polyurethane porous material had excellent tissue biocompatibility and tissue ingrowth. The skin-penetrating pad devised by using this porous material did not cause epidermal downgrowth, suggesting that it may be effective for the prevention of exit-site infection.
Tan, Peng Chiong; Mackeen, Anjana; Khong, Su Yen; Omar, Siti Zawiah; Azmi, M. A. Noor
2016-01-01
A peripheral intravenous catheter is often inserted as part of care during labour. The catheter is inserted into the back of the hand or lower forearm vein in usual practice. There is no trial data to guide the care provider on which is the better insertion site in any clinical setting. 307 women admitted to the labour ward who required insertion of intravenous catheter were randomised to back of hand or lower forearm vein catheter insertion. Catheter insertion is by junior to mid-grade providers. We evaluated insertion success at the first attempt, pain during insertion and catheter replacement due to malfunction as main outcomes. After catheter removal, we recorded patient satisfaction with site, future site preference and insertion site swelling, bruising, tenderness, vein thrombosis and pain. Insertion of a catheter into back of hand vein is more likely to be successful at the first attempt. Insertion pain score, catheter replacement rate, patient satisfaction, patient fidelity to site in a future insertion and insertion site complications rate are not different between trial arms. In conclusion, both insertion sites are suitable; the back of the hand vein maybe easier to cannulate and seems to be preferred by our frontline providers. PMID:26987593
Subramanyam, Haritha; Elumalai, Ramprasad; Kindo, Anupma Jyoti; Periasamy, Soundararajan
2016-01-01
Peritonitis is an inflammation of the peritoneum that occurs in patients with end-stage renal disease (ESRD) treated by peritoneal dialysis. Fungal peritonitis is a dreaded complication of peritoneal dialysis. Curvularia lunata is known to cause extra renal disease like endocarditis, secondary allergic bronchopulmonary aspergillosis and endophthalmitis. This case report presents a case of continuous ambulatory peritoneal dialysis peritonitis with this disease and its management. This case is of a 45-year-old man, presented with ESRD, secondary to diabetic nephropathy. After 3 months of hemodialysis the patient was put on continuous ambulatory peritoneal dialysis (CAPD). Local Examination at catheter site showed skin excoriation and purulent discharge. Further peritoneal dialysis (PD) fluid analysis showed neutrophilic leukocytosis and diagnosis of Curvularia lunata PD peritonitis.
Radiological Tenckhoff catheter insertion for peritoneal dialysis: A cost-effective approach.
Lee, James; Mott, Nigel; Mahmood, Usman; Clouston, John; Summers, Kara; Nicholas, Pauline; Gois, Pedro Henrique França; Ranganathan, Dwarakanathan
2018-04-01
Radiological insertion of Tenckhoff catheters can be an alternative option for peritoneal dialysis access creation, as compared to surgical catheter insertion. This study will review the outcomes and complications of radiological Tenckhoff catheter insertion in a metropolitan renal service and compare costs between surgical and radiological insertion. Data were collected prospectively for all patients who had a Tenckhoff catheter insertion for peritoneal dialysis (PD) under radiological guidance at our hospital from May 2014 to November 2016. The type of catheter used and complications, including peri-catheter leak, exit site infection and peritonitis were reviewed. Follow-up data were also collected at points 3, 6 and 12 months from catheter insertion. Costing data were obtained from Queensland Health Electronic Reporting System (QHERS) data, average staff salaries and consumable contract price lists. In the 30-month evaluation period, 70 catheters were inserted. Two patients had an unsuccessful procedure due to the presence of abdominal adhesions. Seven patients had an episode of peri-catheter leak, and four patients had an exit site infection following catheter insertion. Peritonitis was observed in nine patients during the study period. The majority of patients (90%) remained on peritoneal dialysis at 3-month follow-up. The average costs of surgical and radiological insertion were noted to be AUD$7788.34 and AUD$1597.35, respectively. Radiological Tenckhoff catheter insertion for peritoneal dialysis appears to be an attractive and cost-effective option given less waiting periods for the procedure, the relatively low cost of insertion and comparable rates of complications. © 2017 The Royal Australian and New Zealand College of Radiologists.
DeLemos, Christi; Abi-Nader, Judy; Akins, Paul T
2011-04-01
Patients in neurological critical care units often have lengthy stays that require extended vascular access and invasive hemodynamic monitoring. The traditional approach for these patients has relied heavily on central venous and pulmonary artery catheters. The aim of this study was to evaluate peripherally inserted central catheters as an alternative to central venous catheters in neurocritical care settings. Data on 35 patients who had peripherally inserted central catheters rather than central venous or pulmonary artery catheters for intravascular access and monitoring were collected from a prospective registry of neurological critical care admissions. These data were cross-referenced with information from hospital-based data registries for peripherally inserted central catheters and subarachnoid hemorrhage. Complete data were available on 33 patients with Hunt-Hess grade IV-V aneurysmal subarachnoid hemorrhage. Catheters remained in place a total of 649 days (mean, 19 days; range, 4-64 days). One patient (3%) had deep vein thrombosis in an upper extremity. In 2 patients, central venous pressure measured with a peripherally inserted catheter was higher than pressure measured concurrently with a central venous catheter. None of the 33 patients had a central catheter bloodstream infection or persistent insertion-related complications. CONCLUSIONS Use of peripherally inserted central catheters rather than central venous catheters or pulmonary artery catheters in the neurocritical care unit reduced procedural and infection risk without compromising patient management.
Maksić, Doko; Colić, Miodrag; Stanković-Popović, Verica; Radojević, Milorad; Bokonjić, Dubravko
2007-01-01
Cytokines are essential mediators of immune response and inflammatory reactions. Patients with chronic renal failure and on Continuous Ambulatory Peritoneal Dialysis commonly present abnormalities of immune function related to impaired kidney function, accumulation of uremic toxins and bioincompatibility of peritoneal dialysis solutions. Aim of this study was to examine effects of the CAPD solutions (standard v.s. biocompatible), as well as dialysis duration upon the local and systemic profile of the pro-inflammatory cytokines (IL-1, TNF and IL-6) in patients on CAPD. The cross-sectional study included 44 CAPD patients (27 M and 17 F, average mean age 57.12+/-16.66), of whom 21 patients were on the standard solutions (A.N.D.Y.Disc) for peritoneal dialysis and 23 on the biocompatible solutions (Gambrosol bio trio, Stay Safe balance). The average dialysis treatment period was 3.59+/-2.67 years. In all CAPD patients dialysed longer than 6 months, levels of IL-1. TNF and IL-6 in the serum and dialysis effluent were analysed in the phase without acute infection-related complications (CAPD peritonitis, infection of the catheter exit-site, other acute infections). The control group included 20 patients with the CRF (stage IV and V) whose serum levels of the examined cytokines were also determined. Levels of the inflammatory cytokines were measured by commercial specific ELISA kits (BioSource, Camarillo, California, USA). Statistical analysis of the obtained results was performed by commercial statistics PC software (Stat for Windows, R.4.5. SAD). The serum IL-1 and IL-6 levels were not statistically significantly different in patients on CAPD, irrespective of the type of the used dialysis solutions and in the control group of patients with CRF. The serum TNF levels, unlike IL-1 and IL-6, were statistically significantly higher in patients on CAPD in comparison with the control group of patients (13.203.23 v.s. 5.594.54, p< 0.001, Mann Whitney test). The serum and effluent IL-1 levels in patients on CAPD within one and longer than one year of dialysation did not significantly differ, but the effluent IL-6 levels were significantly higher than in the serum of both groups of patients, that is, effluent IL-6 levels in CAPD patients dialysed more than one year was significantly higher in comparison with those in patients dialysed within a year. Both serum and intraperitoneal levels of the examined cytokines did not significantly differ in patients on the standard and biocompatible solutions, regardless of the present trend toward decrease of intraperitoneal IL-6 levels in patients on biocompatible solutions. Residual renal funcion and number of CAPD peritonitis did not have any important impact upon the serum and IP levels of the examined ctokynes. Elevated serum TNF levels and significant local IL-6 production in our CAPD patients indirectly confirm importance of peritoneal dialysis in amplification of the chronic inflammation substantially depend on the duration of dialysis treatment.
Laparoscopy to evaluate scrotal edema during peritoneal dialysis.
Haggerty, Stephen P; Jorge, Juaquito M
2013-01-01
Acute scrotal edema is an infrequent complication in patients who undergo continuous ambulatory peritoneal dialysis (CAPD), occurring in 2% to 4% of patients. Inguinal hernia is usually the cause, but the diagnosis is sometimes confusing. Imaging modalities such as computed tomographic peritoneography are helpful but can be equivocal. We have used diagnostic laparoscopy in conjunction with open unilateral or bilateral hernia repair for diagnosis and treatment of peritoneal dialysis (PD) patients with acute scrotal edema. TECHNIQUE AND CASES: Three patients with acute scrotal edema while receiving CAPD over the span of 7 years had inconclusive results at clinical examination and on diagnostic imaging. All patients underwent diagnostic laparoscopy that revealed indirect inguinal hernia, which was concomitantly repaired using an open-mesh technique. Diagnostic laparoscopy revealed the etiology of the scrotal edema 100% of the time, with no complications, and allowed concomitant repair of the hernia. One patient had postoperative catheter outflow obstruction, which was deemed to be unrelated to the hernia repair. Diagnostic laparoscopy is helpful in confirming the source of acute scrotal edema in CAPD patients and can be performed in conjunction with an open-mesh repair with minimal added time or risk.
Peripherally inserted central catheters. Guidewire versus nonguidewire use: a comparative study.
Loughran, S C; Edwards, S; McClure, S
1992-01-01
To date, no research articles have been published that explore the practice of using guidewires for placement of peripherally inserted central catheters. The literature contains speculations regarding the pros and cons of guidewire use. However, no studies to date have compared patient outcomes when peripherally inserted central catheter lines are inserted with and without guidewires. To examine the use of guidewires for peripherally inserted central lines, a comparative study was conducted at two acute care facilities, one using guidewires for insertion and one inserting peripherally inserted central catheter lines without guidewires. 109 catheters were studied between January 1, 1990 and January 1, 1991. The primary focus of this study was to examine whether guidewire use places patients at higher risk for catheter-related complications, particularly phlebitis. No significant differences in phlebitis rates between the two study sites were found. Other catheter-related and noncatheter-related complications were similar between the two facilities. The results of this study do not support the belief that guidewire use increases complication rates.
Risk factors associated with PICC-related upper extremity venous thrombosis in cancer patients.
Yi, Xiao-lei; Chen, Jie; Li, Jia; Feng, Liang; Wang, Yan; Zhu, Jia-An; Shen, E; Hu, Bing
2014-03-01
To investigate the incidence and risk factors for peripherally inserted central venous catheters-related upper extremity venous thrombosis in patients with cancer. With the widespread use of peripherally inserted central venous catheters, peripherally inserted central venous catheters-related upper extremity venous thrombosis in patients with cancer leads to increasing morbidity and mortality. It is very important to further explore the incidence and risk factors for peripherally inserted central venous catheters-related venous thrombosis. Consecutive patients with cancer who were scheduled to receive peripherally inserted central venous catheters, between September 2009 and May 2012, were prospectively studied in our centre. They were investigated for venous thrombosis by Doppler sonography three times a day within 30 days after catheter insertion. Univariable and multivariable logistic regressions' analyses were performed to identify the risk factors for peripherally inserted central venous catheters-related thrombosis. A total of 89 patients with cancer were studied in our research. Of these, 81 patients were followed up within one month. The mean interval between catheter insertion and the onset of thrombosis was 12.45 ± 6.17 days. The multivariable analyses showed that chemotherapy history, less activities and diabetes were the key risk factors for thrombosis. Peripherally inserted central venous catheters-related upper extremity venous thrombosis had high incidence rate, and most cases had no significant symptoms. The history of chemotherapy, less activities and diabetes were found to be the key risk factors. It should be routinely scanned in high-risk patients every 3-5 days after catheter insertion, which would then find blood clots in time and reduce the incidence of pulmonary embolism. Risk factors associated with peripherally inserted central venous catheters-related upper extremity venous thrombosis are of critical importance in improving the quality of patients' life. It is very important to grasp the indications to reduce the incidence rate of peripherally inserted central venous catheters-related upper extremity venous thrombosis. © 2013 John Wiley & Sons Ltd.
Peritoneal Dialysis Catheter Insertion.
Crabtree, John H; Chow, Kai-Ming
2017-01-01
The success of peritoneal dialysis as renal-replacement therapy depends on a well-functioning peritoneal catheter. Knowledge of best practices in catheter insertion can minimize the risk of catheter complications that lead to peritoneal dialysis failure. The catheter placement procedure begins with preoperative assessment of the patient to determine the most appropriate catheter type, insertion site, and exit site location. Preoperative preparation of the patient is an instrumental step in facilitating the performance of the procedure, avoiding untoward events, and promoting the desired outcome. Catheter insertion methods include percutaneous needle-guidewire with or without image guidance, open surgical dissection, peritoneoscopic procedure, and surgical laparoscopy. The insertion technique used often depends on the geographic availability of material resources and local provider expertise in placing catheters. Independent of the catheter implantation approach, adherence to a number of universal details is required to ensure the best opportunity for creating a successful long-term peritoneal access. Finally, appropriate postoperative care and catheter break-in enables a smooth transition to dialysis therapy. Copyright © 2017 Elsevier Inc. All rights reserved.
Urethral catheter insertion forces: a comparison of experience and training.
Canales, Benjamin K; Weiland, Derek; Reardon, Scott; Monga, Manoj
2009-01-01
This study was undertaken to evaluate the insertion forces utilized during simulated placement of a urethral catheter by healthcare individuals with a variety of catheter experience. A 21F urethral catheter was mounted to a metal spring. Participants were asked to press the tubing spring against a force gauge and stop when they met a level of resistance that would typically make them terminate a catheter placement. Simulated catheter insertion was repeated fives times, and peak compression forces were recorded. Healthcare professionals were divided into six groups according to their title: urology staff, non-urology staff, urology resident/ fellow, non-urology resident/ fellow, medical student, and registered nurse. A total of fifty-seven healthcare professionals participated in the study. Urology staff (n = 6) had the lowest average insertion force for any group at 6.8 +/- 2.0 Newtons (N). Medical students (n = 10) had the least amount of experience (1 +/- 0 years) and the highest average insertion force range of 10.1 +/- 3.7 N. Health care workers with greater than 25 years experience used significantly less force during catheter insertions (4.9 +/- 1.8 N) compared to all groups (p < 0.01). We propose the maximum force that should be utilized during urethral catheter insertion is 5 Newtons. This force deserves validation in a larger population and should be considered when designing urethral catheters or creating catheter simulators. Understanding urethral catheter insertion forces may also aid in establishing competency parameters for health care professionals in training.
Kim, Jong-Hak; Lee, Jun Seop
2013-01-01
Background Continuous epidural anesthesia is useful for endoscopic urologic surgery, as mostly performed in the elderly patients. In such a case, it is necessary to obtain successful sacral anesthesia, and the insertion of epidural catheter in the caudad direction may be needed. However, continuous epidural catherization has been related to paresthesias. This study aimed to evaluate the effects of the direction of the catheter insertion on the incidence of paresthesias in the elderly patients. Methods Two hundred elderly patients scheduled for endoscopic urologic surgery were enrolled. The epidural catheter was inserted at L2-3, L3-4, and L4-5 using the Tuohy needle. In Group I (n = 100), the Tuohy needle with the bevel directed the cephalad during the catheter insertion. In Group II (n = 100), it directed the caudad. During the catheter insertion, an anesthesiologist evaluated the presence of paresthesias and the ease or difficulty during the catheter insertion. Results In Group I (n = 97), 15.5% of the patients had paresthesias versus 18.4% in Group II (n = 98), and there was no significant difference between the two groups. In paresthesia depending on the insertion site and the ease or difficulty during the catheter insertion, there were no significant differences between the two groups. Conclusions Our results concluded that the direction of epidural catheter insertion did not significantly influence the incidence of paresthesias in the elderly patients. PMID:23741568
Paecilomyces variotii peritonitis in a patient on continuous ambulatory peritoneal dialysis.
Uzunoglu, E; Sahin, A M
2017-06-01
Paecilomyces variotii (P. variotii) is an extremely rare cause of continuous ambulatory peritoneal dialysis (CAPD) peritonitis. When diagnosed, it usually portends poor prognosis. Patient's survival depends on early laboratory diagnosis and proper treatment. We herein report a P. variotii peritonitis in a patient on CAPD which is a quite rare clinical entity. Laboratory diagnosis was confirmed via both morphological analysis and DNA sequencing. Antifungal susceptibility tests were performed and interpreted according to the Clinical Laboratory Standards Institute M38-A2 guidelines. After laboratory diagnosis, the patient was treated succesfully with liposomal amphotericin B and itraconazole combination and the peritoneal catheter was removed. This case is worthy of reporting since P. variotii is an uncommon cause of peritonitis and leads to dilemmas in both laboratory diagnosis and treatment strategies. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Liu, Jian; Huang, Xun; Liu, Yao; Xu, Hui; Gong, Rui'e; Li, Chunhui
2016-12-28
To analyze the clinical characteristics of continuous ambulatory peritoneal dialysis (CAPD) associated peritonitis in the tertiary hospitals and to discuss the preventive and therapeutic strategy. Methods: The clinical characteristics, pathogens, resistance and outcomes of 126 CAPD associated peritonitis in 104 patients from Jan, 2013 to June, 2016, were retrospectively analyzed. Results: Among the patients, the incidence rates of abdominal pain, fever, diarrhea and emesis were 104 (82.54%), 56 (44.44%), 49 (38.89%), and 31 (23.60%), respectively. Among them, 88 patients suffered peritonitis once, other 16 patients suffered multiple peritonitis or recurrent peritonitis for 38 times. Among the 38 times, the numbers for recurrent, repeated or catheter-associated peritonitis were 2, 2, or 3, respectively. Peritoneal fluids from 103 cases were cultured, and 64 cases were positive in bacteria, with a rate of 62.14%. A total of 70 strains of bacteria were separated, including 42 strains of gram-positive bacteria, 21 strains of gram-negative bacteria, and 7 strains of fungus. The most common gram-positive pathogens were Staphylococcus epidermidis, Enterococcus faecalis and Staphylococcus haemolyticus, while Escherichia coli, Klebsiella pneumoniae and Klebsiella pneumoniae were the most common gram-negative bacteria. Candida albicans was the major fungal pathogens. Gram-positive cocci showed resistance to gentamycin, levofloxacin, moxifloxacin, vancomycin and linezolid, with a rate at 20.00%, 36.11%, 5%, 0%, and 0%, respectively. The gram-negative bacilli were resistent to cefoperazone/sulbactam, gentamycin, cephazolin, and ceftazidime, with a rate at 6.25%, 10.53%, 64.29%, and 15.38%, respectively. There were no imipenem, amikacin, piperacillin/tazobactam-resistant strains were found. Conclusion: The most common pathogen causing CAPD associated peritonitis is gram-positive bacteria. It is crucial to take the anti-infection therapy for CAPD associated peritonitis early. The positive rates for bacterial culture need to be enhanced through improvement of methods. At the same time, doctors could improve the outcome of CAPD associated peritonitis by adjusting the medication according to the drug sensitivity results.
FAQs about Catheter-Associated Urinary Tract Infection
... and nurses take the following actions. Catheter insertion o Catheters are put in only when necessary and they are removed as soon as possible. o Only properly trained persons insert catheters using sterile (“ ...
Forgie, Marie M; Greer, Danielle M; Kram, Jessica J F; Vander Wyst, Kiley B; Salvo, Nicole P; Siddiqui, Danish S
2016-03-01
Foley catheters are used for cervical ripening during induction of labor. Previous studies suggest that use of a stylette (a thin, rigid wire) to guide catheter insertion decreases insertion failure. However, stylette effects on insertion outcomes have been sparsely studied. The purpose of this study was to compare catheter insertion times, patient-assessed pain levels, and insertion failure rates between women who received a digitally placed Foley catheter for cervical ripening with the aid of a stylette and women who received the catheter without a stylette. We conducted a randomized clinical trial of women aged ≥ 18 years who presented for induction of labor. Inclusion criteria were singletons with intact membranes and cephalic presentation. Women received a computer-generated random assignment of a Foley catheter insertion with a stylette (treatment group, n = 62) or without a stylette (control group, n = 61). For all women, a standard insertion technique protocol was used. Three primary outcomes were of interest, including the following: (1) insertion time (total minutes to successful catheter placement), (2) patient-assessed pain level (0-10), and (3) failure rate of the randomly assigned insertion method. Treatment control differences were first examined using the Pearson's test of independence and the Student t test. Per outcome, we also constructed 4 regression models, each including the random effect of physician and fixed effects of stylette use with patient nulliparity, a history of vaginal delivery, cervical dilation at presentation, or postgraduate year of the performing resident physician. Women who received the Foley catheter with the stylette vs without the stylette did not differ by age, race/ethnicity, body mass index, or any of several other characteristics. Regression models revealed that insertion time, patient pain, and insertion failure were unrelated to stylette use, nulliparity, and history of vaginal delivery. However, overall insertion time and failure were significantly influenced by cervical dilation, with insertion time decreasing by 21% (95% confidence interval [CI], 5-34%) and odds of failure decreasing by 71% (odds ratio, 0.29; 95% CI, 0.10-0.86) per 1 cm dilation. Resident postgraduate year also significantly influenced insertion time, with greater time required of physicians with less experience. Mean insertion time was 51% (95% CI, 23-69%) shorter for fourth-year than second-year residents. Statistically nonsignificant but prominent patterns in outcomes were also observed, suggesting stylette use may lengthen the overall insertion procedure but minimize variability in pain levels and decrease insertion failure. The randomized trial suggests that, even after accounting for nulliparity, history of vaginal delivery, cervical dilation, and physician experience, Foley catheter insertions with and without a stylette are equivalent in insertion times, patient pain levels, and failure of catheter placement. Copyright © 2016 Elsevier Inc. All rights reserved.
Krishnaiah, Anil; Soothill, James; Wade, Angie; Mok, Quen Q; Ramnarayan, Padmanabhan
2012-05-01
To compare the rate of central venous catheter-associated bloodstream infections between pediatric intensive care unit admissions where central venous catheters were inserted within the same hospital (internal central venous catheters) and those where central venous catheters were inserted before transfer from other hospitals (external central venous catheters). Retrospective analysis of prospectively collected data. A tertiary care pediatric intensive care unit in London, UK. Consecutive pediatric intensive care unit admissions between May 2007 and March 2009. None. Catheter-associated bloodstream infections were identified using a widely accepted surveillance definition. The rate and time to occurrence of catheter-associated bloodstream infection were compared between internal and external nontunneled central venous catheters. A multilevel Cox-regression model was used to study the association between location of central venous catheter insertion and time to catheter-associated bloodstream infection. In total, 382 central venous catheters were studied (245 internal; 137 external) accounting for a total of 1,737 central venous catheter days. There was a higher catheter-associated bloodstream infection incidence density among external central venous catheters (23.1 [95% confidence interval 11.0-35.2] vs. 9.7 [95% confidence interval 3.9-15.5] per 1,000 catheter-days). Multivariable analyses demonstrated higher infection risk with external central venous catheters (hazard ratio 2.65 [95% confidence interval 1.18-5.96]) despite adjustment for confounding variables. The rate of catheter-associated bloodstream infections in the pediatric intensive care unit is significantly affected by external insertion of the central venous catheter. Future interventions to reduce nosocomial infections on pediatric intensive care units will need to be specifically targeted at this high-risk patient group.
Prevention of Device-Related Healthcare-Associated Infections
Septimus, Edward J.; Moody, Julia
2016-01-01
Healthcare-associated infections (HAIs) are a leading cause of morbidity and mortality in hospitalized patients. Up to 15% of patients develop an infection while hospitalized in the United States, which accounts for approximately 1.7 million HAIs, 99,000 deaths annually and over 10 billion dollars in costs per year. A significant percentage of HAIs are preventable using evidenced-based strategies. In terms of device-related HAIs it is estimated that 65-70% of catheter-line associated bloodstream infections (CLABSIs) and catheter-associated urinary tract infections (CAUTIs) are preventable. To prevent CLABSIs a bundle which includes hand hygiene prior to insertion and catheter manipulation, use of chlorhexidene alcohol for site preparation and maintenance, use of maximum barrier for catheter insertion, site selection, removing nonessential lines, disinfect catheter hubs before assessing line, and dressing changes are essential elements of basic practices. To prevent CAUTIs a bundle that includes hand hygiene for insertion and catheter or bag manipulation, inserting catheters for appropriate indications, insert using aseptic technique, remove catheters when no longer needed, maintain a close system keeping bag and tubing below the bladder are the key components of basic practices. PMID:26918162
Occurrence of Phlebitis: A Systematic Review and Meta-analysis.
Chang, Wen P; Peng, Yu X
Peripheral venous catheters (PVCs) are commonly used in clinical practice. However, varying degrees of phlebitis often occur in patients receiving intravenous injections. The relevant literature suggests that phlebitis occurrence is highly associated with the catheter gauge, insertion site, and catheterization duration. Nevertheless, no meta-analysis has been performed on the influence of these three factors on the occurrence of phlebitis. The objective of this study was to determine whether any significant differences exist in the occurrence of phlebitis between catheters of 20 gauge or smaller and those larger than 20 gauge, between catheters inserted in the antecubital fossa and those inserted in other locations on the upper limbs, or between catheters inserted for more than 96 hours and those inserted for 96 hours or less. Using a systematic approach, we searched for literature published between 2006 and 2017 in the Cumulative Index to Nursing and Allied Health Literature (CINAHL), PubMed, ProQuest, and Cochrane Library databases. We used Comprehensive Meta-analysis Version 2 to perform our meta-analysis. After the screening and review processes, we identified 17 studies that met our selection conditions. Among these studies, 14 contained complete data for meta-analysis. These studies involved 4,343 patients and 5,846 PVCs. Regarding the overall effect size in the meta-analysis, the results of the forest plot comparing catheters of 20 gauge or smaller and those larger than 20 gauge presented a risk ratio (RR) of 0.88 (95% confidence interval [0.67, 1.17], p = .380), indicating no statistically significant difference in the occurrence of phlebitis between catheters of the aforementioned gauges. The results of the forest plot comparing catheters inserted in the antecubital fossa and those inserted in other locations on the upper limbs presented an RR of 1.05 (95% confidence interval [0.82, 1.34], p = .696), indicating no statistically significant difference in the occurrence of phlebitis between catheters inserted in the aforementioned locations. The results of the forest plot comparing catheters inserted for more than 96 hours and those inserted for 96 hours or less presented an RR of 1.13 (95% confidence interval [0.49, 2.61], p = .779), indicating no statistically significant difference in the occurrence of phlebitis between catheters inserted for the aforementioned durations. The empirical results of this meta-analysis can serve as a reference for hospital management for selecting the PVC gauge, insertion site, and catheterization duration. In addition to the three factors that we analyzed, whether any other factors influence the occurrence of phlebitis in patients with catheter implantation is worth investigating in future research.
Teixidó, J; Arias, N; Tarrats, L; Romero, R
2007-01-01
A prospective cohort study was undertaken to compare the rates of the infecting microorganisms of the peritoneal catheter exit-site in three periods of the prophylactic protocol of a peritoneal dialysis program. All patients treated for more than one month on Peritoneal Dialysis were included: Fourty-eight in Period 1 (P1), 48 in Period 2 (P2), and 54 in Period 3 (P3). Each period was of 3 years. Infection prophylaxis protocol: P1: hydrogen peroxide or povidone iodine and non-occlusive dressing; P2: sterile water (boiled water) instead of antiseptic agents, semi-permeable dressing for taking showers, and nasal mupirocine prophylaxis for Staphylococcus aureus carriers; P3: equal to P2, plus local application of antibiotics in equivocal exit-site for infection and argentic nitrate in granulation tissue. The rates of catheter infection and microorganisms causing infection were analysed by means of the Poisson regression method. Chi-square and ANOVA when appropriate. The proportion of catheters implanted by nephrologist or surgeon (p<0.01) and modality treatment by CAPD or CCPD (p<0.0001) were significantly different in the three periods, while the Staph. Aureus carrieres was in the limit of significance (p=0.048). Throughout the three periods, a significantly decreasing rate of total (P=0.0035) and acute infections (P<0.001), Staph. aureus (P=0.003) and peritonitis (P=0.0025) were found. The Pseudomonas aer. (P=0.006) and Gram negative Bacteria (P=0.023) decreased significantly in P2. The multiple factor analysis included eight factors: sex, age group, ESRD, DM, catheter implantation (nephrologist, surgeon), modality treatment (CAPD, CCPD), manufacturer and prophylaxis period as possible predictors of the catheter infections, the specific microorganisms and the peritonitis. That analysis revealed the prophylaxis period as the main predictive factor of the improvements found (p<0.02,- p<0.001). In contrast, the Corynebacteria spp. increased significantly (P=0.008) throughout the three periods. One half of the Corynebacteria in each period could be considered colonisers. The other half caused true infections, but not one of those episodes required catheter intervention. The non-diphtheria Corynebacteria increase was found related with the continuous cycling Peritoneal Dialysis treatment in multiple factor analysis (p=0.0023) and in the proportion analysis (P=0.039, c2). The progressive protocol applied obtained good results, without the continued use of local antiseptics or antibiotics at the exit-site. However, the non-diphtheria Corynebacteria sp. infection increment favours the consideration of an antiseptic agent for the exit-site care.
The Effect of Intravenous Infiltration Management Program for Hospitalized Children.
Park, Soon Mi; Jeong, Ihn Sook; Kim, Kyoung Lae; Park, Kyung Ju; Jung, Moon Ju; Jun, Seong Suk
2016-01-01
This study aimed to identify the effect of IV infiltration management program among hospitalized children. This was a quasi-experimental study with history comparison group design with 2,894 catheters inserted during 3 months comparison phase and 3,651 catheters inserted during 4 months experimental phase. The intervention was composed of seven activities including applying poster, documentation of catheter insertion, parents education, making infiltration report, assessment of vein condition before inserting catheter, appropriate site selection, and documentation of catheter insertion, and assessment of peripheral catheter insertion site every shift. Data were analyzed using of X2-test, Fisher's exact test. The infiltration incidence rate was 0.9% for experimental group and 4.4% for comparison group, which was significantly different (x2=80.42, p<.001). The catheter maintenance period (p=.035) and infiltration state (p=.039) were significantly different among participants with infiltration between comparison and experimental groups. IV Infiltration management program was founded to be effective in reducing the IV infiltration incidence rate and increasing early detection of IV infiltration. Considering the effect of IV Infiltration management program, we recommend that this infiltration management program would be widely used in the clinical settings. Copyright © 2016 Elsevier Inc. All rights reserved.
Spanos, Stephanie; Booth, Rebekah; Koenig, Heidi; Sikes, Kendra; Gracely, Edward; Kim, In K
2008-08-01
Peripheral intravenous (PIV) catheter insertion is a frequent, painful procedure that is often performed with little or no anesthesia. Current approaches that minimize pain for PIV catheter insertion have several limitations: significant delay for onset of anesthesia, inadequate anesthesia, infectious disease exposure risk from needlestick injuries, and patients' needle phobia. Comparison of the anesthetic effectiveness of J-Tip needle-free jet injection of 1% buffered lidocaine to the anesthetic effectiveness of topical 4% ELA-Max for PIV catheter insertion. A prospective, block-randomized, controlled trial comparing J-Tip jet injection of 1% buffered lidocaine to a 30-minute application of 4% ELA-Max for topical anesthesia in children 8 to 15 years old presenting to a tertiary care pediatric emergency department for PIV catheter insertion. All subjects recorded self-reported visual analog scale (VAS) scores for pain at time of enrollment and pain felt following PIV catheter insertion. Jet injection subjects also recorded pain of jet injection. Subjects were videotaped during jet injection and PIV catheter insertion. Videotapes were reviewed by a single blinded reviewer for observer-reported VAS pain scores for jet injection and PIV catheter insertion. Of the 70 children enrolled, 35 were randomized to the J-Tip jet injection group and 35 to the ELA-Max group. Patient-recorded enrollment VAS scores for pain were similar between groups (P = 0.74). Patient-recorded VAS scores were significantly different between groups immediately after PIV catheter insertion (17.3 for J-Tip jet injection vs 44.6 for ELA-Max, P < 0.001). Blinded reviewer assessed VAS scores for pain after PIV catheter insertion demonstrated a similar trend, but the comparison was not statistically significant (21.7 for J-Tip jet injection vs 31.9 ELA-Max, P = 0.23). J-Tip jet injection of 1% buffered lidocaine provided greater anesthesia than a 30-minute application of ELA-Max according to patient self-assessment of pain for children aged 8 to 15 years undergoing PIV catheter insertion.
Changing concepts in long-term central venous access: catheter selection and cost savings.
Horattas, M C; Trupiano, J; Hopkins, S; Pasini, D; Martino, C; Murty, A
2001-02-01
Long-term central venous access is becoming an increasingly important component of health care today. Long-term central venous access is important therapeutically for a multitude of reasons, including the administration of chemotherapy, antibiotics, and total parenteral nutrition. Central venous access can be established in a variety of ways varying from catheters inserted at the bedside to surgically placed ports. Furthermore, in an effort to control costs, many traditionally inpatient therapies have moved to an outpatient setting. This raises many questions regarding catheter selection. Which catheter will result in the best outcome at the least cost? It has become apparent in our hospital that traditionally placed surgical catheters (ie, Hickmans and central venous ports) may no longer be the only options. The objective of this study was to explore the various modalities for establishing central venous access comparing indications, costs, and complications to guide the clinician in choosing the appropriate catheter with the best outcome at the least cost. We evaluated our institution's central venous catheter use during a 3-year period from 1995 through 1997. Data was obtained retrospectively through chart review. In addition to demographic data, specific information regarding catheter type, placement technique, indications, complications, and catheter history were recorded. Cost data were obtained from several departments including surgery, radiology, nursing, anesthesia, pharmacy, and the hospital purchasing department. During a 30-month period, 684 attempted central venous catheter insertions were identified, including 126 surgically placed central venous catheters, 264 peripherally inserted central catheters by the nursing service, and 294 radiologically inserted peripheral ports. Overall complications were rare but tended to be more severe in the surgical group. Relative cost differences between the groups were significant. Charges for peripherally inserted central catheters were $401 per procedure, compared with $3870 for radiologically placed peripheral ports and $3532 to $4296 for surgically placed catheters. Traditional surgically placed central catheters are increasingly being replaced by peripherally inserted central venous access devices. Significant cost savings and fewer severe complications can be realized by preferential use of peripherally inserted central catheters when clinically indicated. Cost savings may not be as significant when comparing radiologically placed versus surgically placed catheters. However, significant cost savings and fewer severe complications are associated with peripheral central venous access versus the surgical or radiologic approach.
Galiczewski, Janet M; Shurpin, Kathleen M
2017-06-01
Healthcare associated infections from indwelling urinary catheters lead to increased patient morbidity and mortality. The purpose of this study was to determine if direct observation of the urinary catheter insertion procedure, as compared to the standard process, decreased catheter utilization and urinary tract infection rates. This case control study was conducted in a medical intensive care unit. During phase I, a retrospective data review was conducted on utilsiation and urinary catheter infection rates when practitioners followed the institution's standard insertion algorithm. During phase II, an intervention of direct observation was added to the standard insertion procedure. The results demonstrated no change in utilization rates, however, CAUTI rates decreased from 2.24 to 0 per 1000 catheter days. The findings from this study may promote changes in clinical practice guidelines leading to a reduction in urinary catheter utilization and infection rates and improved patient outcomes. Copyright © 2016 Elsevier Ltd. All rights reserved.
Complications Related to Insertion and Use of Central Venous Catheters (CVC).
Hodzic, Samir; Golic, Darko; Smajic, Jasmina; Sijercic, Selma; Umihanic, Sekib; Umihanic, Sefika
2014-10-01
Central Venous Catheters (CVC) are essential in everyday medical practice, especially in treating patients in intensive care units (ICU). The application of these catheters is accompanied with the risk of complications, such as the complications caused during the CVC insertion, infections at the location of the insertion, and complications during the use of the catheter, sepsis and other metastatic infections. This study is a retrospective-prospective and it was implemented in the period 1(st) January 2011- 31(st) December 2012. It included 108 examinees with CVC placed for more than 7 days. The most common complications occurring in more than 2 attempts of CVC applications are: hearth arrhythmias in both groups in 12 cases, 7 in multi-lumen (12.72%) and 5 in mono-lumen ones (9.43%). Artery puncture occurs in both groups in 7 cases, 5 in multi-lumen (9.09%) and 2 in mono-lumen ones (3.77%). Hematoma occurred in both groups in 4 cases, 3 in multi-lumen CVCs (5.45%) and 1 in mono-lumen ones (1.88%). The most common complication in multi-lumen catheters was heart arrhythmia, in 20 cases (36.37%). The most common complications in mono-lumen CVCs was hearth arrhythmias, in 20 cases as extrasystoles and they were registered in 16 catheter insertions (30.18%). Out of total number of catheters of both groups, out of 108 catheters the complications during insertion occurred in 49 catheters (45.40%). The most common complications in both groups were heart arrhythmias, artery punctures and hematomas at the place of catheter insertion.
Use of simulation-based education to reduce catheter-related bloodstream infections.
Barsuk, Jeffrey H; Cohen, Elaine R; Feinglass, Joe; McGaghie, William C; Wayne, Diane B
2009-08-10
Simulation-based education improves procedural competence in central venous catheter (CVC) insertion. The effect of simulation-based education in CVC insertion on the incidence of catheter-related bloodstream infection (CRBSI) is unknown. The aim of this study was to determine if simulation-based training in CVC insertion reduces CRBSI. This was an observational education cohort study set in an adult intensive care unit (ICU) in an urban teaching hospital. Ninety-two internal medicine and emergency medicine residents completed a simulation-based mastery learning program in CVC insertion skills. Rates of CRBSI from CVCs inserted by residents in the ICU before and after the simulation-based educational intervention were compared over a 32-month period. There were fewer CRBSIs after the simulator-trained residents entered the intervention ICU (0.50 infections per 1000 catheter-days) compared with both the same unit prior to the intervention (3.20 per 1000 catheter-days) (P = .001) and with another ICU in the same hospital throughout the study period (5.03 per 1000 catheter-days) (P = .001). An educational intervention in CVC insertion significantly improved patient outcomes. Simulation-based education is a valuable adjunct in residency education.
Bilir, Ayten; Yelken, Birgül; Erkan, Ayse
2013-06-01
Protection of the catheter site by antimicrobial agents is one of the most important factors in the prevention of infection. Povidone iodine and chlorhexidine gluconate are the most common used agents for dressing. The purpose of this study was to compare the effects of povidone iodine, chlorhexidine gluconate and octenidine hydrochloride in preventing catheter related infections. Patients were randomized to receive; 4% chlorhexidine gluconate, 10% povidone iodine or octenidine hydrochlorodine for cutaneous antisepsis. Cultures were taken at the site surrounding catheter insertion and at the catheter hub after removal to help identify the source of microorganisms. Catheter related sepsis was 10.5% in the povidone iodine and octenidine hydrochlorodine groups. Catheter related colonization was 26.3% in povidone iodine group and 21.5% in octenidine hydrochlorodine group. 4% chlorhexidine or octenidine hydrochlorodine for cutaneous disinfection before insertion of an intravascular device and for post-insertion site care can reduce the catheter related colonization.
Revel-Vilk, S; Yacobovich, J; Tamary, H; Goldstein, G; Nemet, S; Weintraub, M; Paltiel, O; Kenet, G
2010-09-01
The use of central venous catheters (CVCs) has greatly improved the quality of care in children with cancer, yet these catheters may cause serious infectious and thrombotic complications. The aim of this prospective registry study was to assess the host and CVC-related risk factors for CVC-created thrombotic complications. Patients undergoing CVC insertion for chemotherapy were followed prospectively for CVC complications. At the time of enrollment, demographic, clinical, and CVC-related data, and family history of thrombosis were collected. Survival and Cox regression analyses were performed. A total of 423 CVCs were inserted into 262 patients for a total of 76,540 catheter days. The incidence of CVC-related deep-vein thrombosis (DVT) was 0.13 per 1000 catheter-days (95% confidence interval [CI], 0.06-0.24). Insertion of peripherally inserted central catheters (PICCs) and insertion in an angiography suite significantly increased the risk of symptomatic CVC-related DVT. The incidence of CVC occlusion was 1.35 per 1000 catheter-days (95% CI, 1.1-1.63). Positive family history of thrombosis significantly increased the risk of CVC occlusion (hazard ratio [HR], 2.16; 95% CI, 1.2-3.8). The CVC-related risk factors were insertion of Hickman catheters, insertion in angiography suite, and proximal-tip location. Patients developing at least 1 episode of both CVC occlusion and infection had an increased risk for developing symptomatic CVC-related DVT (HR, 4.15; 95% CI, 1.2-14.4). Both patient-related and CVC-related factors are associated with higher risk of symptomatic thrombotic complications. These risk factors could be used in the clinical setting and in developing future studies for CVC thromboprophylaxis.
Browne, C; Norton, S; Nolan, J M; Whelan, C; Sullivan, J F; Quinlan, M; Sheikh, M; Mc Dermott, T E D; Lynch, T H; Manecksha, R P
2018-02-01
Undergraduate training in core urology skills is lacking in many Irish training programmes. Our aim was to assess newly qualified doctors' experience and confidence with core urological competencies. A questionnaire survey covering exposure to urology and confidence with core clinical skills was circulated to all candidates. The group then attended a skills course covering male/female catheterisation, insertion of three-way catheters, bladder irrigation and management of long-term suprapubic catheters. The groups were re-surveyed following the course. Forty-five interns completed the pre-course questionnaire (group 1) and 27 interns completed the post-course questionnaire (group 2). 24/45 (53%) had no experience of catheter insertion on a patient during their undergraduate training. 26/45 (58%) were unsupervised during their first catheter insertion. 12/45 (27%) had inserted a female catheter. 18/45 (40%) had inserted a three-way catheter. 12/45 (27%) had changed a suprapubic catheter. 40/45 (89%) in group 1 reported 'good' or 'excellent' confidence with male urinary catheterisation, compared to 25/27 (92.5%) in group 2. 18/45 (40%) in group 1 reported 'none' or 'poor' confidence with female catheterisation, compared to 7/27 (26%) in group 2. 22/45 (49%) in group 1 reported 'none' or 'poor' confidence with insertion of three-way catheters, compared to 2/27 (7%) in group 2. 32/45 (71%) in group 1 reported 'none' or 'poor' confidence in changing long-term suprapubic catheters, falling to 3/27 (11%) in group 2. This study raises concerns about newly qualified doctors' practical experience in urology. We suggest that this course improves knowledge and confidence with practical urology skills and should be incorporated into intern induction.
De Boo, Diederick W; Mott, Nigel; Tregaskis, Peter; Quach, Trung; Menahem, Solomon; Walker, Rowan G; Koukounaras, Jim
2015-12-01
Various methods of peritoneal dialysis (PD) catheter insertion are available. The purpose of this study was to evaluate a percutaneous insertion technique using ultrasound (US) and fluoroscopy performed under conscious sedation and as day case procedure. Data of 87 percutaneous inserted dialysis catheters were prospectively collected, including patients' age, gender, body mass index, history of previous abdominal surgery and cause of end stage renal failure. Length of hospital stay, early complications and time to first use were also recorded. Institutional review board approval was obtained. A 100% technical success rate was observed. Early complications included bleeding (n = 3), catheter dysfunction (n = 6), exit site infection (n = 1) and exit site leakage (n = 1). All cases of catheter dysfunction and one case of bleeding required surgical revision. Median time of follow-up was 18 months (range 3-35), and median time from insertion to first use was days 14 (1-47). Of the 82 patients who started dialysis, 20 (23%) ceased PD at some stage during follow-up. Most frequently encountered reasons include deteriorating patient cognitive or functional status (n = 5), successful transplant kidney (n = 4) and pleuro-peritoneal fistula (n = 4). Sixty-two (71%) PD catheter insertions were performed as day case. The remaining insertions were performed on patients already admitted to the hospital. Percutaneous insertion of dialysis catheter using US and fluoroscopy is not only safe but can be performed as day case procedure in most patients, even with a medical history of abdominal surgery and/or obesity. © 2015 The Royal Australian and New Zealand College of Radiologists.
Nomura, Jason T; Sierzenski, Paul R; Nace, Jason E; Bollinger, Melissa
2008-07-01
Use of ultrasound guidance for Central Venous Catheter insertion has been associated with decreased complications and increased success rates. Previous reports show low rates of use among physicians. Evaluation of the frequency of Ultrasound Guidance use for Central Venous Catheter insertion among residents at a teaching institution. A cross sectional electronic survey of resident physicians at a tertiary care teaching hospital was conducted to evaluate use of Ultrasound Guidance for Central Venous Catheterization. Assessment included self reported frequency of ultrasound guidance use, and volume of central venous catheter placement. Attitudes toward the use of ultrasound were assessed using Likert scales. There is a high rate. over 90%, of ultrasound guidance use for Internal Jugular central venous catheters among residents. The majority of residents use sterile real-time imaging with a single operator with a reported success rate greater then 80%. Resident use of ultrasound guidance for Internal Jugular central venous catheter insertion can be much higher than previously reported in the literature.
Perl, Jeffrey; Pierratos, Andreas; Kandasamy, Gokulan; McCormick, Brendan B; Quinn, Robert R; Jain, Arsh K; Huang, Anjie; Paterson, J Michael; Oliver, Matthew J
2015-02-01
The likelihood of peritoneal dialysis (PD) utilization following a PD catheter insertion attempt is poorly described. We explored the risk factors for PD nonuse, focusing on the method of PD catheter implantation. This population-based retrospective cohort study employed Ontario administrative health data to identify 3886 predialysis adults who had an incident PD catheter implantation between 2002 and 2010. The impact of the method of catheter implantation including open-surgical (open, n = 1884), surgical-laparoscopic (laparoscopic, n = 1154), nephrology-percutaneous (nephrology, n = 498) and radiology-percutaneous (radiology, n = 350) on rates of PD utilization (defined as four consecutive weeks of PD) was examined. Eighty-three percent of study patients received PD. After adjustment, relative to patients with openly inserted catheters, PD utilization was greater for those with nephrology-inserted catheters [adjusted hazard ratio (aHR) 1.59, 95% confidence interval (CI) 1.29-1.95] and similar for radiology-inserted catheters [aHR 1.16, 95% CI 0.94-1.43] or laparoscopic-inserted catheters [aHR 0.97 (95% CI 0.86-1.09)]. Among PD nonusers, death occurred in 10% of the open group, 6% of the laparoscopic group, 27% of the radiology group and in fewer than 3% of the nephrology group. Sixty-nine percent received hemodialysis in the open group, 63% in the laparoscopic group, 61% in the radiology group and 88% in the nephrology group. Those remaining predialysis comprised 12% of the open group, 22% of the laparoscopic group, 11% of the radiology group and <3% of the nephrology group. Nephrology insertion resulted in lower overall rates of PD nonuse, particularly due to death or remaining predialysis. Greater use may be related to insertion timing, technique or greater commitment on the part of nephrologists to the success of PD. © The Author 2014. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.
Holmfred, Anette; Vikerfors, Thomas; Berggren, Lars; Gupta, Anil
2006-06-01
Intrathecal catheters have been used for many years to treat severe pain resistant to conventional treatment modalities. Previous studies have found a rate of serious infection of 2%-3% using these catheters in home situations. However, many authors used prophylactic antibiotics routinely in this group of patients, which are both costly and associated with a risk of developing antibiotic resistance. We were interested in studying whether improved hygiene during insertion and care of these catheters in the hospice or home environment would reduce the incidence of catheter-related infections. The results show that prophylactic antibiotic is not necessary, but a careful handling of the system with aseptic technique is important. The infections we registered appeared more than 2 weeks after insertion of the catheters. We now use this method routinely when inserting an intrathecal catheter with a subcutaneous port.
Bilir, Ayten; Yelken, Birgül; Erkan, Ayse
2013-01-01
Background: Protection of the catheter site by antimicrobial agents is one of the most important factors in the prevention of infection. Povidone iodine and chlorhexidine gluconate are the most common used agents for dressing. The purpose of this study was to compare the effects of povidone iodine, chlorhexidine gluconate and octenidine hydrochloride in preventing catheter related infections. Materials and Methods: Patients were randomized to receive; 4% chlorhexidine gluconate, 10% povidone iodine or octenidine hydrochlorodine for cutaneous antisepsis. Cultures were taken at the site surrounding catheter insertion and at the catheter hub after removal to help identify the source of microorganisms. Results: Catheter related sepsis was 10.5% in the povidone iodine and octenidine hydrochlorodine groups. Catheter related colonization was 26.3% in povidone iodine group and 21.5% in octenidine hydrochlorodine group. Conclusion: 4% chlorhexidine or octenidine hydrochlorodine for cutaneous disinfection before insertion of an intravascular device and for post-insertion site care can reduce the catheter related colonization. PMID:24250702
Majdan, Maria; Stepniak, Cezary; Piotrowicz, Sebastian; Broniek, Karina; Blajer, Beata; Bednarek-Skublewska, Anna
2005-04-01
The chronic nephropathy is often present in pts with rheumatoid arthritis (RA). In the study the authors retrospectively analyzed the clinical course of the disease and outcomes of subsequent dialysotherapy in a group of pts with RA and end-stage renal disease ESRD. During last 5 years ESRD connected with RA was found in 10 (8 F, 2 M) pts out of 325 chronically dialyzed pts (peritoneal dialysis and hemodialysis) representing 3,1% of pts. The mean age at the initiation of dialysotherapy in these pts was 62,8 +/- 10,2 (range 46-76) years. Mean time from the diagnosis of RA to the start of dialysotherapy was 18,8 +/- 11,6 (range 5-40) years. Earlier the patients were treated with many disease modifying antirheumatic drugs (DMARDS) also with glucocorticosteroids and many nonsteroidal anti-inflammatory drugs. It means that they had rather aggressive type of RA. Amyloidosis was histological confirmed in 6 pts (4 F, 2 M). Peritoneal dialysis (PD) was the first choice therapy in 8 pts (2 on APD, 6 on CAPD). The main complication was increased incidence of peritonitis. 3 pts died on PD after 5, 9, 24 months (respectively) of CAPD treatment. 3 pts were transferred to HD after 5, 15, 18 (respectively) months of CAPD because of recurrent peritonitis. 2 pts up to date continue PD (one 12 months, the second 46 months on CAPD). In 5 pts who needed hemodialysis treatment there have been very serious problems with permanent vascular access formation. All used permanent indwelling catheters (Permcath). We concluded that: occurrence of ESRD in pts with RA was connected with aggressive type of disease. Pts with RA represent a dialysis group that is particularly prone to complications of PD (enteric peritonitis) and HD (vascular access problems). It seems to be connected with secondary vasculitis often found in pts with aggressive type of RA.
Endoscopic-Assisted Burr Hole Reservoir and Ventricle Catheter Placement.
Antes, Sebastian; Tschan, Christoph A; Heckelmann, Michael; Salah, Mohamed; Senger, Sebastian; Linsler, Stefan; Oertel, Joachim
2017-05-01
Accurate positioning of a ventricle catheter is of utmost importance. Various techniques to ensure optimal positioning have been described. Commonly, after catheter placement, additional manipulation is necessary to connect a burr hole reservoir or shunt components. This manipulation can lead to accidental catheter dislocation and should be avoided. Here, we present a new technique that allows direct endoscopic insertion of a burr hole reservoir with an already mounted ventricle catheter. Before insertion, the ventricle catheter was slit at the tip, shortened to the correct length, and connected to the special burr hole reservoir. An intracatheter endoscope was then advanced through the reservoir and the connected catheter. This assemblage allowed using the endoscope as a stylet for shielded ventricular puncture. To confirm correct placement of the ventricle catheter, the endoscope was protruded a few millimeters beyond the catheter tip for inspection. The new technique was applied in 12 procedures. The modified burr hole reservoir was inserted for first-time ventriculoperitoneal shunting (n = 1), cerebrospinal fluid withdrawals and drug administration (n = 2), or different stenting procedures (n = 9). Optimal positioning of the catheter was achieved in 11 of 12 cases. No subcutaneous cerebrospinal fluid collection or fluid leakage through the wound occurred. No parenchymal damage or bleeding appeared. The use of the intracatheter endoscope combined with the modified burr hole reservoir provides a sufficient technique for accurate and safe placement. Connecting the ventricle catheter to the reservoir before the insertion reduces later manipulation and accidental dislocation of the catheter. Copyright © 2017 Elsevier Inc. All rights reserved.
Dettenkofer, M; Jonas, D; Wiechmann, C; Rossner, R; Frank, U; Zentner, J; Daschner, F D
2002-10-01
We investigated the efficacy of two commercially available, alcohol-based antiseptic solutions in decontaminating the insertion site of central lines. One solution contained the bispyridine octenidine dihydrochloride. Inpatients receiving either a central venous catheter (CVC) or a peripherally inserted central catheter (PICC) were alternately assigned to different skin disinfection regimens at the insertion site: (A) 0.1% octendine dihydrochloride with 30% 1-propanol and 45% 2-propanol, (B) 74% ethanol with 10% 2-propanol. Quantitative skin cultures were obtained from the insertion site at predetermined intervals. A total of 60 patients received 12 CVCs and 47 PICCs (no significant difference with respect to gender, age and catheter type). In total, 90 cultures were assessed in each group. The median colony-forming unit (cfu) counts per 24 cm(2) (group A vs B) were 2,270 vs 2,950 before, 20 vs 40 following and 860 vs 1,210 24 h after catheter insertion, respectively. A statistically significant difference in the efficacy of skin decontamination was seen between groups in culture set (3) and in the difference between culture sets (2) and (3) (Wilcoxon rank sum test). Octenidine/propanol appears to be more effective than alcohol (ethanol/propanol) alone in reducing microflora of the skin at the PICC/CVC insertion site over a 24-h period.
Wong, W M; Tam, T Cc; Wong, M Ky; Lui, M Ms; Ip, M Sm; Lam, D Cl
2016-08-01
Malignant pleural effusion can be recurrent despite active anti-cancer treatment. Significant malignant pleural effusion leads to debilitating dyspnoea and worsening quality of life in patients with advanced cancer. An indwelling pleural catheter offers a novel means to manage recurrent malignant pleural effusion and may remove the need for repeated thoracocentesis. Spontaneous pleurodesis is another unique advantage of indwelling pleural catheter placement but the factors associated with its occurrence are not clearly established. The aims of this study were to explore the safety of an indwelling pleural catheter in the management of symptomatic recurrent malignant pleural effusion, and to identify the factors associated with spontaneous pleurodesis. This case series with internal comparisons was conducted in the Division of Respiratory Medicine, Department of Medicine, Queen Mary Hospital, Hong Kong. All patients who underwent insertion of an indwelling pleural catheter from the initiation of such service from January 2010 to December 2014 were included for data analysis. Patients were monitored until December 2014, with the last catheter inserted in July 2014. Between 2010 and 2014, a total of 23 indwelling pleural catheters were inserted in 22 consecutive patients with malignant pleural effusion, including 15 (65.2%) cases with malignant pleural effusion as a result of metastatic lung cancer. Ten (43.5%) cases achieved minimal output according to defined criteria, in five of whom the pleural catheter was removed without subsequent re-accumulation of effusion (ie spontaneous pleurodesis). Factors associated with minimal output were the absence of trapped lung (P=0.036), shorter time from first appearance of malignant pleural effusion to catheter insertion (P=0.017), and longer time from catheter insertion till patient's death or end of study (P=0.007). An indwelling pleural catheter provides a safe means to manage symptomatic malignant pleural effusion. Potential clinical factors associated with minimal output were identified along with the occurrence of spontaneous pleurodesis, which is a unique advantage offered by indwelling pleural catheter.
Emoli, Alessandro; Cappuccio, Serena; Marche, Bruno; Musarò, Andrea; Scoppettuolo, Giancarlo; Pittiruti, Mauro
2014-01-01
The ISP (Safe Insertion of PICCs) protocol: a bundle of 8 recommendations to minimize the complications related to the peripherally inserted central venous catheters (PICC). The insertion of a peripherally inserted central venous catheter (PICC) is not without risks. The Italian Group for the Study of Long-Term Central Venous Access Devices (GAVeCeLT) has developed a protocol (SIP: Safe Implantation of PICCs) with the aim of minimizing the risks which may be associated with the placement of PICCs. The protocol is based on recommendations available in the literature and on the main clinical practice guidelines. The SIP protocol, a bundle of evidence-based recommendations, it is is easy to use, inexpensive, and cost-effective. If routinely used and carefully inplemented, it greatly reduces complications such as failure of venipuncture, accidental arterial puncture, damage of median nerve, infection and catheter related venous thrombosis.
Advantages and disadvantages of surgical placement of PD catheters with regard to other methods.
Stegmayr, B
2006-01-01
Peritoneal dialysis is underused for various reasons. One reason may be problems with insertion of catheters for access. Another reason is the delayed start (break-in period) of about 2 weeks after operation. This review describes various approaches to the insertion of a peritoneal dialysis catheter. The optimal conditions to strive for are given as is an overview of various techniques. This article favours surgical placement while others might prefer other techniques. Described is the use a 3-purse string suture technique that allows immediate start of dialysis after catheter insertion both for acute dialysis indications as well as for acute start in chronic dialysis patients. A key to lesser complications is to establish a team devoted to the insertions rather than to allow various physicians to perform insertions as a training procedure. An optimal access is one of the important life lines for these patients.
Percutaneous transfemoral repositioning of malpositioned central venous catheters.
Hartnell, G G; Roizental, M
1995-04-01
Central venous catheters inserted by blind surgical placement may not advance into a satisfactory position and may require repositioning. Malpositioning via surgical insertion is common in patients in whom central venous catheters have previously been placed, as these patients are more likely to have central venous thrombosis and distortion of central venous anatomy. This is less of a problem when catheter placement is guided by imaging; however, even when insertion is satisfactory, central venous catheters may become displaced spontaneously after insertion (Fig. 1). Repositioning can be effected by direct manipulation using guidewires or tip-deflecting wires [1, 2], by manipulation via a transfemoral venous approach [3-5], and by injection of contrast material or saline [6]. Limitations of the direct approach include (1) the number and type of maneuvers that can be performed to effect repositioning when anatomy is distorted, (2) difficulty in accessing the catheter, and (3) the risk of introducing infection. Moreover, these patients are often immunosuppressed, and there is a risk of introducing infection by exposing and directly manipulating the venous catheter. Vigorous injection of contrast material or saline may be unsuccessful for the same reasons: It seldom exerts sufficient force to reposition large-caliber central venous catheters and may cause vessel damage or rupture if injection is made into a small or thrombosed vessel. We illustrate several alternative methods for catheter repositioning via a transfemoral venous approach.
Rodrigues, Jorge; Dias, Andrea; Oliveira, Guiomar; Farela Neves, José
2016-06-01
To determine the central-line associated bloodstream infection rate after implementation of central venous catheter-care practice bundles and guidelines and to compare it with the previous central-line associated bloodstream infection rate. A prospective, longitudinal, observational descriptive study with an exploratory component was performed in a Pediatric Intensive Care Unit during five months. The universe was composed of every child admitted to Pediatric Intensive Care Unit who inserted a central venous catheter. A comparative study with historical controls was performed to evaluate the result of the intervention (group 1 versus group 2). Seventy five children were included, with a median age of 23 months: 22 (29.3%) newborns; 28 (37.3%) with recent surgery and 32 (43.8%) with underlying illness. A total of 105 central venous catheter were inserted, the majority a single central venous catheter (69.3%), with a mean duration of 6.8 ± 6.7 days. The most common type of central venous catheter was the short-term, non-tunneled central venous catheter (45.7%), while the subclavian and brachial flexure veins were the most frequent insertion sites (both 25.7%). There were no cases of central-line associated bloodstream infection reported during this study. Comparing with historical controls (group 1), both groups were similar regarding age, gender, department of origin and place of central venous catheter insertion. In the current study (group 2), the median length of stay was higher, while the mean duration of central venous catheter (excluding peripherally inserted central line) was similar in both groups. There were no statistical differences regarding central venous catheter caliber and number of lumens. Fewer children admitted to Pediatric Intensive Care Unit had central venous catheter inserted in group 2, with no significant difference between single or multiple central venous catheter. After multidimensional strategy implementation there was no reported central-line associated bloodstream infection Conclusions: Efforts must be made to preserve the same degree of multidimensional prevention, in order to confirm the effective reduction of the central-line associated bloodstream infection rate and to allow its maintenance.
Tietz, Andreas; Frei, Reno; Dangel, Marc; Bolliger, Dora; Passweg, Jakob R; Gratwohl, Alois; Widmer, Andreas E
2005-08-01
To determine the efficacy and tolerability of octenidine hydrochloride, a non-alcoholic skin antiseptic, for the care of central venous catheter (CVC) insertion sites. Prospective, observational study. Bone marrow transplantation unit of a university hospital. All consecutive patients with a nontunneled CVC were enrolled prospectively after informed consent. Octenidine hydrochloride (0.1%) was applied for disinfection at the CVC insertion site during dressing changes. The following cultures were performed weekly as well as at the occurrence of any systemic inflammatory response syndrome criteria: cultures of the skin surrounding the CVC entry site, cultures of the three-way hub connected to the CVC, blood cultures, and cultures of the CVC tip on removal. Enhanced microbiological methods (skin swabs of a 24-cm2 standardized area, roll plate, and sonication of catheter tips) were applied. One hundred thirty-five CVCs were inserted in 62 patients during the study period and remained for a mean period of 19.1 days, corresponding to 2,462 catheter-days. Bacterial density at the insertion site declined substantially over time, and most cultures became negative 2 weeks after insertion. Only 6 patients had a documented catheter-related bloodstream infection. The incidence density was 2.39 catheter infections per 1,000 catheter-days. No side effects were noted with application of the antiseptic. Disinfection with a skin antiseptic that contains octenidine hydrochloride is highly active and well tolerated. It leads to a decrease in skin colonization over time and may be a new option for CVC care.
An adverse event of suprapubic catheter SPC insertion. A call for updating the existing guidelines.
Jalil, Rozh; Mukundan, Chandrika; Bhatti, Tahir S
2012-11-15
The suprapubic catheter (SPC) is a useful and widely used tool in urological practice. However, complications can arise from its insertion or ongoing care. We add to the literature a case of an adverse event of its insertion where it has gone through a vascular graft and recommending updating the SPC insertion guidelines.
Small bowel injury after suprapubic catheter insertion presenting 3 years after initial insertion
Gallagher, Kevin M; Good, Daniel W; Brush, John P; Al-hasso, Ammar; Stewart, Grant D
2013-01-01
A 77-year-old woman was referred to urology with blockages of her suprapubic catheter (SPC). The catheter was replaced easily in the emergency department, however, no urine was draining, only a cloudy green fluid was visible. On cystoscopy bilious material was identified in the bladder. There was no catheter visible. There seemed to be a fistulous tract entering the bladder at the left dome. The urethra was dilated, a urethral catheter was placed and the SPC was removed. A CT demonstrated that the SPC tract transfixed a loop of pelvic small bowel and entered the bladder with no intraperitoneal contrast leak. The patient recovered well and did not require laparotomy. This case emphasises that bowel perforation, although rare, must be considered as a complication of SPC placement even years after initial insertion when catheter problems arise. Unusually, we learn that this complication may not present with abdominal pain or peritonism. PMID:24326435
21 CFR 876.5130 - Urological catheter and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... device that is inserted through the urethra and used to pass fluids to or from the urinary tract. This..., coude catheters, balloon retention type catheters, straight catheters, upper urinary tract catheters...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lucey, Brian; Varghese, Jose C.; Haslam, Philip
1999-09-15
Purpose: To study the cost and impact on patient management of the routine performance of chest radiographs in patients undergoing imaged-guided central venous catheter insertion. Methods: Six hundred and twenty-one catheters placed in 489 patients over a 42-month period formed the study group. Catheters were placed in the right internal jugular vein (425), left internal jugular vein (133), and subclavian veins (63). At the end of the procedure fluoroscopy was used to assess catheter position and check for complications. A postprocedural chest radiograph was obtained in all patients. Results: Postprocedural chest fluoroscopy showed no evidence of pneumothorax, hemothorax, or mediastinalmore » hematoma. Inappropriate catheter tip position or catheter kinks were noted with 90 catheters. These problems were all corrected while the patient was on the interventional table. Postprocedural chest radiographs showed no complications but proximal catheter tip migration was noted in six of 621 catheters (1%). These latter six catheters required further manipulation. The total technical and related charges for the postprocedural chest radiographs in this series were estimated at Pounds 15,525. Conclusion: Postprocedural chest radiographs after image-guided central venous catheter insertion are not routinely required. A postprocedural chest radiograph can be performed on a case-by-case basis at the discretion of the interventional radiologist.« less
[Central venous catheter-related infections in critically ill patients].
Diener, J R; Coutinho, M S; Zoccoli, C M
1996-01-01
To determine incidence rate, etiology and risk factors for central venous catheter (CVC)-related infections in critically-ill patients, a prospective cohort study was conducted in the general Intensive Care Unit (ICU) of a 212 bed Hospital in Florianópolis, Brazil. Patients admitted to ICU between May 1993 and February 1994, exposed to short-term CVC, were included in the study. Quantitative skin culture at CVC insertion site, semi-quantitative CVC tip culture, quantitative hub culture, and peripheral blood-culture were done. Results were submitted to univariate and multivariate analysis. Fifty-seven catheterization periods were analysed in 51 patients. The incidence rate was 21.1% (33.1 per 1,000 catheter-days) for local infection, and 8.7% (14.1 per 1,000 catheter-days) for catheter-associated bacteremia. The skin at the insertion site was colonized in 32.7% and the hub in 29.1% of the patients respectively. Potential sources of infection were the skin in 41.2% of the cases, the hub in 29.4%, remote site in 5.9% and unknown in 23.5%. The hub was implicated in 60% of the catheter-associated bacteremias. Coagulase-negative staphylococci were the main isolates. Another intravascular device and purulence at the insertion site were independently associated with local infection. Insertion at internal jugular site and hub colonization were independently associated with bacteremia. Catheter-associated bacteremia is a major complication of central venous catheterization in critically-ill patients. Internal jugular insertion and CVC hub colonization are important risk factors for significant catheter-related infections.
Fadoo, Zehra; Nisar, Muhammad I; Iftikhar, Raza; Ali, Sajida; Mushtaq, Naureen; Sayani, Raza
2015-10-01
Peripherally inserted central venous catheters (PICC) have been successfully used to provide central access for chemotherapy and frequent transfusions. The purpose of this study was to assess the feasibility of PICCs and determine PICC-related complications in pediatric hematology/oncology patients in a resource-poor setting. All pediatric patients (age below 16 y) with hematologic and malignant disorders who underwent PICC line insertion at Aga Khan University Hospital from January 2008 to June 2010 were enrolled in the study. Demographic features, primary diagnosis, catheter days, complications, and reasons for removal of device were recorded. Total of 36 PICC lines were inserted in 32 pediatric patients. Complication rate of 5.29/1000 catheter days was recorded. Our study showed comparable complication profile such as infection rate, occlusion, breakage, and dislodgement. The median catheter life was found to be 69 days. We conclude that PICC lines are feasible in a resource-poor setting and recommend its use for chemotherapy administration and prolonged venous access.
... to the blood vessel as the needle and catheter are inserted Blood clot traveling to the lungs, causing an embolism Excessive bleeding or a blood clot where the catheter is inserted, which can reduce blood flow to ...
Salimi, Fereshte; Imani, Mohammad Reza; Ghasemi, Navab; Keshavarzian, Amir; Jazi, Amir Hosein Davarpanah
2013-01-01
Background: Long-term tunneled catheters are used for the hemodialysis or chemotherapy in many patients. Proper placement of the catheter tip could reduce early and late catheter related complications. Aim of the present study was to evaluate a new formula for proper placement of tunneled hemodialysis or infusion port device by using an external anatomic landmark. Materials and Methods: A total of 64 adult patients undergoing elective placement of tunneled Central Venous Catheter (CVC) requiring hemodialysis or chemotherapy were enrolled in this prospective study during 2011-2012 in the university hospital. The catheter length to be inserted in the right internal jugular vein (IJV) was calculated by adding two measurements (the shortest straight length between the insertion point of the needle and the suprasternal notch plus and half of sternal length). The catheter position was considered correct if the tip was positioned in the right atrium (RA) or Superior vena cava (SVC)-RA junction. Results: The patients were 55.28 ± 19.85 years of age, weighed 5.78 ± 16.62 kg and were 166.07 ± 10.27 cm tall. Catheters were inserted successfully in 88% of patients (n = 56). Catheter tip positions in the failures were SVC (n = 5), tricuspid valve (n = 2), and right ventricle (n = 1) in our patients. Conclusion: Long-term hemodialysis or port CVC could easily insert in the right IJV by using half of the sternal length as an external land marks among adult patients. PMID:24174941
Peripherally inserted central catheters in the neonatal period.
Uygun, Ibrahim; Okur, Mehmet Hanifi; Otcu, Selcuk; Ozturk, Hayrettin
2011-10-01
Peripherally inserted central catheters (PICC) have been extensively used in neonates. However, insertion of these thinnest catheters is a very delicate procedure associated with a high failure rate. In our Neonatal Surgical Intensive Care Unit, we developed a very easy new PICC insertion and evaluated the neonates treated with PICCs which were inserted by using our technique as well as catheter features such as success rate, number of insertion attempts, reason for removal and complications. Information was retrospectively collected on all 40 PICCs inserted at Kutahya Evliya Celebi Goverment Hospital and Dicle University Hospital during a 6-years period from September 2004 to September 2010. A total of 40 PICCs were inserted in 37 patients (26, 70% males, 11, 30% females) by using new technique. The median age of patients was 8.3 days (range 1 to 66 days) and the median weight of patients was 2365 g (range 600 to 5000 g). The vein most commonly accessed was long saphenous vein (85%). The length of PICCs in the body was 19.6 cm (range 5 cm to 30 cm). The tip was located in a central vein in all patients. Surgical abdomen was the most common cause for PICC insertion (38%). Duration of catheterization was 7.7±5.6 days (1-F 5.5 days, 2-F 8.6 days). Almost all of the PICCs were inserted successfully (40/42, success rate 95%) and in the first venipucture (36/42, 86%). Completion of therapy and removed after death were achieved with 87% of PICCs. Three minor complications were noted. Minor bleeding in the insertion site which was stopped via compression occurred in two neonates. Major complication was not seen. No deaths were directly attributed to PICCs use. The new insertion technique of the neonatal peripherally inserted central catheters may be one of the easiest and safest techniques, in comparison to previous techniques reported in the literature.
A Study of Use of “PORT” Catheter in Patients with Cancer: A Single-Center Experience
Madabhavi, Irappa; Patel, Apurva; Sarkar, Malay; Anand, Asha; Panchal, Harsha; Parikh, Sonia
2017-01-01
Background: Effective and reliable venous access is one of the cornerstones of modern medical therapy in oncology. Materials and methods: This is a prospective observational study, which collected data of patients who require “PORT” catheter insertion for any cancer, at a tertiary care oncology hospital in Ahmadabad, Gujarat, India, during a 2-year period. Aims and objectives: The main objective of this study was to study the various complications and outcomes related to “PORT” catheters. Results: “PORT” catheter was inserted in 100 patients and was most commonly used in solid malignancies (n = 86, 86%), followed by hematologic malignancies (n = 14, 14%). Among the solid malignancies, breast cancer (38, 38%) was the most common underlying disease, whereas among the hematologic malignancies, acute lymphoblastic leukemia (6, 6%) was the most common underlying disease for “PORT” catheter insertion. Chemotherapy was started on the first day of “PORT” catheter in 74% of patients in the “PORT” study group. The various complications developed in the “PORT” study group in the descending order are as follows: 4 patients (4%) developed early infection (⩽30 days after “PORT” placement), 4 (4%) late infection (⩾30 days after “PORT” placement), 4 (4%) bloodstream infection, 2 (2%) local skin infection at the “PORT” insertion site, 2 (2%) dislodgment of the “PORT” catheter, 2 (2%) fracture of the “PORT” catheter, and 1 recurrent pleural effusion. One patient (1%) developed thrombosis as the complication of “PORT” catheter insertion. Conclusions: The most disturbing aspect of treatment for a patient with cancer is multiple painful venipunctures made for administration of cytotoxic agents, antibiotics, blood products, and nutritional supplements. The focus of this prospective observational research is to study the various underlying diseases for which “PORT” catheter is needed in different solid and hematologic malignancies and the various complications and outcomes in pediatric and adult patients with cancer. PMID:28469510
Long-Term Outcomes of Single-Port Laparoscopic Placement of Peritoneal Dialysis Catheter.
Pan, Alan; Poi, Mun J; Matos, Jesus; Jiang, Jenny S; Kfoury, Elias; Echeverria, Angela; Bechara, Carlos F; Lin, Peter H
2016-07-01
Laparoscopic insertion of peritoneal dialysis (PD) catheter has become a preferred method compared to the traditional open technique for PD catheter insertion. We retrospectively report the outcome of 1-port laparoscopic placement PD catheters in our institution. A total of 263 patients with end-stage renal disease who underwent single-trocar laparoscopic PD catheter insertion during a recent 6-year period were reviewed. Laparoscopic technique involves introducing a PD catheter over a stiff guidewire into the abdominal cavity through a 10-mm laparoscopic port. Pertinent clinical variables, procedural complications, and follow-up outcome were analyzed. There were 182 men and 81 women. The mean age was 56 years. Technical success was 95.8%. Catheter occlusion was the most common early complications (<6 months) that occurred in 4 (1.5%) patients. Late complications (> 6 months) including catheter occlusion, cuff extrusion, catheter leakage, catheter migration, infection, and hernia occurred in 5 patients (1.9%), 2 patients (0.8%), 3 patients (1.1%), 3 patients (1.1%), 6 patients (2.3%), and 4 patients (1.5), respectively. Mean follow-up time was 39 ± 18 months. Catheter survival rate at 1, 2, 3, 4, and 5 years was 96%, 94%, 90%, 85%, and 82%, respectively. Laparoscopic PD catheter implantation via a single-trocar utilizing a stiff guidewire technique is feasible and safe. This method can result in low complication and high catheter survival rate. © The Author(s) 2016.
Stewart, Jessica K; Smith, Tony P; Kim, Charles Y
To determine the clinical implications of acute pelvicaliceal hematoma formation during percutaneous catheter nephrostomy (PCN) insertion. Collecting system hematoma burden was retrospectively assessed for 694 PCN insertions in 502 patients. Pelvicaliceal hematoma formation occurred in 146 kidneys (21%) in 136 patients. Clinically significant blood loss occurred in 3 patients with hematomas within one week compared to 4 patients without hematomas (p=0.39). Twenty-four patients with hematomas underwent catheter exchange within one week, compared to 55 patients without hematomas (p=0.49). Pelvicaliceal hematoma formation after PCN insertion is not uncommon and is associated with very rare clinical sequelae. Copyright © 2017 Elsevier Inc. All rights reserved.
Benvenuti, Stefano; Ceresoli, Rosanna; Boroni, Giovanni; Parolini, Filippo; Porta, Fulvio; Alberti, Daniele
2018-03-01
The aim of our study was to present our experience with the use of peripherally inserted central catheters (PICCs) in pediatric patients receiving autologous or allogenic blood stem-cell transplantation. The insertion of the device in older children does not require general anesthesia and does not require a surgical procedure. From January 2014 to January 2017, 13 PICCs were inserted as a central venous device in 11 pediatric patients submitted to 14 autologous or allogeneic stem-cell transplantation, at the Bone Marrow Transplant Unit of the Children's Hospital of Brescia. The mean age of patients at the time of the procedure was 11.3 years (range 3-18 years). PICCs remained in place for an overall period of 4104 days. All PICCs were positioned by the same specifically trained physician and utilized by nurses of our stem-cell transplant unit. No insertion-related complications were observed. Late complications were catheter ruptures and line occlusions (1.2 per 1000 PICC days). No rupture or occlusion required removal of the device. No catheter-related venous thrombosis, catheter-related bloodstream infection (CRBSI), accidental removal or permanent lumen occlusion were observed. Indications for catheter removal were completion of therapy (8 patients) and death (2 patients). Three PICCs are currently being used for blood sampling in follow-up patients after transplantation. Our data suggest that PICCs are a safe and effective alternative to conventional central venous catheters even in pediatric patients with high risk of infectious and hemorrhagic complications such as patients receiving stem-cell transplantation.
U. S. Army Medical Research and Development Technical Report
1978-09-30
skin preparation prior to cathe- ter insertion, thi- type of catheter care following insertion, and the duration of central venous catheterization . An...NO. 3 A study is now underway to determine the optimal techniques for central venous catheter dressing care. A specially designed dress- ing tray that...chronically maintained male rhesus monkeys with indwelling central venous catheters. Two specific problems were en- countered. (1) Available data
Kulvatunyou, N; Erickson, L; Vijayasekaran, A; Gries, L; Joseph, B; Friese, R F; O'Keeffe, T; Tang, A L; Wynne, J L; Rhee, P
2014-01-01
Small pigtail catheters appear to work as well as the traditional large-bore chest tubes in patients with traumatic pneumothorax, but it is not known whether the smaller pigtail catheters are associated with less tube-site pain. This study was conducted to compare tube-site pain following pigtail catheter or chest tube insertion in patients with uncomplicated traumatic pneumothorax. This prospective randomized trial compared 14-Fr pigtail catheters and 28-Fr chest tubes in patients with traumatic pneumothorax presenting to a level I trauma centre from July 2010 to February 2012. Patients who required emergency tube placement, those who refused and those who could not respond to pain assessment were excluded. Primary outcomes were tube-site pain, as assessed by a numerical rating scale, and total pain medication use. Secondary outcomes included the success rate of pneumothorax resolution and insertion-related complications. Forty patients were enrolled. Baseline characteristics of 20 patients in the pigtail catheter group were similar to those of 20 patients in the chest tube group. No patient had a flail chest or haemothorax. Pain scores related to chest wall trauma were similar in the two groups. Patients with a pigtail catheter had significantly lower mean(s.d.) tube-site pain scores than those with a chest tube, at baseline after tube insertion (3.2(0.6) versus 7.7(0.6); P < 0.001), on day 1 (1.9(0.5) versus 6.2(0.7); P < 0.001) and day 2 (2.1(1.1) versus 5.5(1.0); P = 0.040). The decreased use of pain medication associated with pigtail catheter was not significantly different. The duration of tube insertion, success rate and insertion-related complications were all similar in the two groups. For patients with a simple, uncomplicated traumatic pneumothorax, use of a 14-Fr pigtail catheter is associated with reduced pain at the site of insertion, with no other clinically important differences noted compared with chest tubes. NCT01537289 (http://clinicaltrials.gov). © 2013 BJS Society Ltd. Published by John Wiley & Sons Ltd.
Related factors with extravasation of non-cytostatic agents in peripheral vein catheters.
Fernández-García, Cristina; Mata-Peón, Esther; Avanzas-Fernández, Sara
To know the independent variables related to the occurrence of extravasation in patients with peripheral vein catheters (PVC). Retrospective study carried out in 6 longitudinal cuts between July 2013 an January 2014. A total of 1,442 PVC were reviewed, of which 730 met the inclusion criteria, and were divided into 2 groups: extravasation and not extravasation, with 365 cases each. The variables of age, gender, admission unit, catheter gauge, insertion site, previous insertion into the same limb, hospital unit where the insertion took place, communication difficulties, personal health history and analyzed parenterally drug administered were considered. Risk factors to develop extravasation were: female gender, with previous insertion in the same limb, <72h PVC of insertion, communication difficulties, personal health history of neoplasia and KCl, gentamicin or beta lactam treatment. Our study allows to know the variables that are related to the emergence of extravasations in patients with non-cancer treatments (gender, medical service of admission, catheter gauge, elapsed time since the insertion, patient communication difficulties, personal health history, and intravenous treatments), as well as the factors that may be considered protective. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.
Impact of Ultrasound on Short Peripheral Intravenous Catheter Placement on Vein Thrombosis Risk.
Holder, Max R; Stutzman, Sonja E; Olson, DaiWai M
Approximately 90% of hospitalized patients have a short peripheral intravenous catheter (SPC) placed. Methods of inserting the catheter have evolved over time and now include the use of ultrasound (US)-guided procedures for placement. Little is known about the impact that US-guided procedures have on the vein. This study compared the rate of venous thrombosis in patients with and without US-guided catheter placement. This prospective, single-blind, observational study assessed for venous thrombosis in 153 veins from 135 patients. Veins were evaluated by a research nurse blinded to the method of placement between 48 and 72 hours after the SPC was placed. The Fisher exact test showed a significant difference between vessel compressibility and catheter insertion method (P = .0012). The proportion of noncompressible veins was significantly greater when US was used in comparison with freehand SPC insertion. The Mantel-Haenszel chi-square value of 10.34 (P = .0013) showed that US insertion technique is associated with a higher likelihood of noncompressible veins. This pilot study provides compelling evidence that the use of US to assist with catheter placement is associated with a higher rate of noncompressible veins at day 2 or 3. Further studies are needed with a larger sample to determine the generalizability of the results from this pilot study.
Bouman, E A C; Gramke, H F; Wetzel, N; Vanderbroeck, T H T; Bruinsma, R; Theunissen, M; Kerkkamp, H E M; Marcus, M A E
2007-01-01
Although epidural anesthesia is considered safe, several complications may occur during puncture and insertion of a catheter. Incidences of paresthesia vary between 0.2 and 56%. A prospective, open, cohort-controlled pilot study was conducted in 188 patients, ASA I-III, age 19-87 years, scheduled for elective surgery and epidural anesthesia. We evaluated a 20 G polyamide (standard) catheter and a 20 G combined polyurethane-polyamide (new) catheter. Spontaneous reactions upon catheter-insertion, paresthesia on questioning, inadvertent dural or intravascular puncture, and reasons for early catheter removal were recorded. The incidence of paresthesia reported spontaneously was 21.3% with the standard catheter and 16.7% with the new catheter. Systematically asking for paresthesia almost doubled the paraesthesia rate. Intravascular cannulation occurred in 5%. No accidental dural punctures occurred. An overall incidence of 13.3% of technical problems led to early catheter removal. The new catheter was at least equivalent to the standard regarding epidural success rate and safety : rate of paresthesia, intravascular and dural cannulation.
[Reducing the Incidence of Phlebitis Related to Intravenous Injection in Pediatric Patients].
Cho, Yen-Hua; Yen, Li-Ling; Yu, Kai-Ling; Chang, Chun-Chu; Chen, Hsuen-Ling
2015-06-01
Peripheral venous catheter (PVC) is commonly used to provide nutrition and medicine to pediatric inpatients. Phlebitis is a common side effect of PVC insertion. Over 90% of pediatric patients in the paedi-atric medical ward at the Chang Gung Memorial Hospital (CGMH) receive PVC insertion, with an incident rate of phlebitis of 5.07%. Common cause factors of phlebitis are: insufficient sterilization time, inappropriate methods used to fix the PVC, the use of fixtures that loosen easily, high re-fix rates, and inadequate wound care after catheter removal. The purpose of this project was to reduce the incidence rate of PVC-insertion-related phlebitis in children from 5.07% to 2.5%. A one-week clinical observation identified the re-inserting / re-fixing of existing PVCs as the principal cause of phlebitis in the CGMH paediatric ward. Therefore, the researchers modified the catheter care bundle based on a review of the literature and the suggestions of clinical pediatric experts. Modifications included applying 2% chlorhexidine to sterilize the insertion site; using a new, non-woven fabric splint to fix the PVC site; providing cartoon-themed waterproof dressings for the first bath after the removal of the PVC; and setting standard operating procedures (SOPs) for PVC insertion and catheter removal. After applying these modifications, the incident rate of phlebitis in children with PVC insertions decreased from 5.07% to 2.08%. The application of 2% chlorhexidine reduces the waiting time for sterilization; the purpose-designed splint strengthens the fixation of the PVC; and the development of the SOPs for PVC insertion and post-removal catheter care reduces the risk of phlebitis. The combination of these strategies effectively reduces the incidence of phlebitis and improves the nursing care quality.
Coberly, LeAnn; Goldenhar, Linda M
2007-04-01
To assess acting interns' (AI's) experience with and perceived level of competency performing 6 basic medical procedures. Fourth-year medical students at the University of Cincinnati (UCCOM) are required to complete 2 AI rotations in Internal Medicine. All AIs in 2003-2004 (n = 150) and 2004-2005 (n = 151) were asked to complete a survey about whether during each of their rotations they had performed and felt competent performing the following procedures: phlebotomy, intravenous (IV) catheter insertion, arterial blood gas (ABG), nasogastric (NG) tube insertion, lumbar puncture (LP), and Foley catheter insertion. Four hundred sixty-seven of 601 possible surveys (across both years and both rotations) were completed (78% response rate). During both rotations, relatively few students performed the procedures, ranging from 9% for Foley catheter insertion (24/208) to 50% for both ABG and NG tube insertion (130/259). The two procedures most often performed were ABG (range 46-50%) and NG tube insertion (range 42-50%). Feelings of competency varied from 12% (LP) to 82% (Foley catheter). Except for LP, if students performed a procedure at least once, they reported feeling more competent (range 85% for ABG to 96% for Foley catheter insertion). Among the students who performed LP during a rotation, many still did not feel competent performing LPs: 23 (74%) in rotation 1 and 20 (40%) in rotation 2. Many fourth-year students at UCCOM do not perform basic procedures during their acting internship rotations. Procedural performance correlates with feelings of competency. Lumbar puncture competency may be too ambitious a goal for medical students.
Body surface infrared thermometry in patients with central venous cateter-related infections
Silvah, José Henrique; de Lima, Cristiane Maria Mártires; de Unamuno, Maria do Rosário Del Lama; Schetino, Marco Antônio Alves; Schetino, Luana Pereira Leite; Fassini, Priscila Giácomo; Brandão, Camila Fernanda Costa e Cunha Moraes; Basile, Anibal; da Cunha, Selma Freire Carvalho; Marchini, Julio Sergio
2015-01-01
Objective To evaluate if body surface temperature close to the central venous catheter insertion area is different when patients develop catheter-related bloodstream infections. Methods Observational cross-sectional study. Using a non-contact infrared thermometer, 3 consecutive measurements of body surface temperature were collected from 39 patients with central venous catheter on the following sites: nearby the catheter insertion area or totally implantable catheter reservoir, the equivalent contralateral region (without catheter), and forehead of the same subject. Results A total of 323 observations were collected. Respectively, both in male and female patients, disregarding the occurrence of infection, the mean temperature on the catheter area minus that on the contralateral region (mean ± standard deviation: -0.3±0.6°C versus -0.2±0.5ºC; p=0.36), and the mean temperature on the catheter area minus that on the forehead (mean ± standard deviation: -0.2±0.5°C versus -0.1±0.5ºC; p=0.3) resulted in negative values. Moreover, in infected patients, higher values were obtained on the catheter area (95%CI: 36.6-37.5ºC versus 36.3-36.5ºC; p<0.01) and by temperature subtractions: catheter area minus contralateral region (95%CI: -0.17 - +0.33ºC versus -0.33 - -0.20ºC; p=0.02) and catheter area minus forehead (95%CI: -0.02 - +0.55ºC versus -0.22 - -0.10ºC; p<0.01). Conclusion Using a non-contact infrared thermometer, patients with catheter-related bloodstream infections had higher temperature values both around catheter insertion area and in the subtraction of the temperatures on the contralateral and forehead regions from those on the catheter area. PMID:26466058
Body surface infrared thermometry in patients with central venous cateter-related infections.
Silvah, José Henrique; Lima, Cristiane Maria Mártires de; Unamuno, Maria do Rosário Del Lama de; Schetino, Marco Antônio Alves; Schetino, Luana Pereira Leite; Fassini, Priscila Giácomo; Brandão, Camila Fernanda Costa e Cunha Moraes; Basile-Filho, Anibal; Cunha, Selma Freire Carvalho da; Marchini, Julio Sergio
2015-01-01
To evaluate if body surface temperature close to the central venous catheter insertion area is different when patients develop catheter-related bloodstream infections. Observational cross-sectional study. Using a non-contact infrared thermometer, 3 consecutive measurements of body surface temperature were collected from 39 patients with central venous catheter on the following sites: nearby the catheter insertion area or totally implantable catheter reservoir, the equivalent contralateral region (without catheter), and forehead of the same subject. A total of 323 observations were collected. Respectively, both in male and female patients, disregarding the occurrence of infection, the mean temperature on the catheter area minus that on the contralateral region (mean ± standard deviation: -0.3±0.6°C versus-0.2±0.5ºC; p=0.36), and the mean temperature on the catheter area minus that on the forehead (mean ± standard deviation: -0.2±0.5°C versus-0.1±0.5ºC; p=0.3) resulted in negative values. Moreover, in infected patients, higher values were obtained on the catheter area (95%CI: 36.6-37.5ºC versus 36.3-36.5ºC; p<0.01) and by temperature subtractions: catheter area minus contralateral region (95%CI: -0.17 - +0.33ºC versus -0.33 - -0.20ºC; p=0.02) and catheter area minus forehead (95%CI: -0.02 - +0.55ºC versus-0.22 - -0.10ºC; p<0.01). Using a non-contact infrared thermometer, patients with catheter-related bloodstream infections had higher temperature values both around catheter insertion area and in the subtraction of the temperatures on the contralateral and forehead regions from those on the catheter area.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Too, Chow Wei, E-mail: toochowwei@gmail.com; Sayani, Raza; Lim, Elvin Yuan Ting
PurposeTo describe a technique involving REcanalisation and Balloon-Oriented puncture for Re-insertion of dialysis catheter in Nonpatent central veins (REBORN) and to report long-term results.Materials and MethodsThis is a retrospective study of ten subjects in whom dialysis catheters were inserted using the REBORN technique from March 2012 to October 2014 and followed up till April 2016. Data on the duration of catheter usage, complications and reasons for removal were obtained. Seven patients had partially occluded lower internal jugular veins (IJV) recanalised in an antegrade fashion via a more cranial puncture. The balloon was then inflated at usual puncture site with anmore » 18G needle. The collapsed balloon was cannulated with a guide wire, and both balloon and guide wire were advanced together into the superior vena cava. This was followed by tunnelled catheter placement using standard techniques. Two patients had catheters placed in the subclavian vein using a similar antegrade technique, and one patient had catheter placed via the left IJV following retrograde recanalisation from a right femoral puncture.ResultsMean duration of catheter use was 278 days (range 32–503). Three catheters were removed due to matured arteriovenous accesses. Four patients had successful catheter change over the same subcutaneous track due to catheter malfunction. One catheter was removed after 7 months because of sepsis. No complications were reported.ConclusionThe REBORN technique allows for the preservation of central veins for future haemodialysis access, which can be challenging in patients requiring long-term dialysis.« less
Grady, Janet L; Kehrer, Rosemary G; Trusty, Carole E; Entin, Eileen B; Entin, Elliot E; Brunye, Tad T
2008-09-01
Simulation technologies are gaining widespread acceptance across a variety of educational domains and applications. The current research examines whether basic nursing procedure training with high-fidelity versus low-fidelity mannequins results in differential skill acquisition and perceptions of simulator utility. Fifty-two first-year students were taught nasogastric tube and indwelling urinary catheter insertion in one of two ways. The first group learned nasogastric tube and urinary catheter insertion using high-fidelity and low-fidelity mannequins, respectively, and the second group learned nasogastric tube and urinary catheter insertion using low-fidelity and high-fidelity mannequins, respectively. The dependent measures included student performance on nasogastric tube and urinary catheter insertion testing, as measured by observer-based instruments, and self-report questionnaires probing student attitudes about the use of simulation in nursing education. Results demonstrated higher performance with high-fidelity than with low-fidelity mannequin training. In response to a self-report posttraining questionnaire, participants expressed a more positive attitude toward the high-fidelity mannequin, especially regarding its responsiveness and realism.
Prospective comparison of two management strategies of central venous catheters in burn patients.
Kealey, G P; Chang, P; Heinle, J; Rosenquist, M D; Lewis, R W
1995-03-01
Central venous catheters (CVCs) are associated with sepsis in burn patients. This study was undertaken to compare two strategies of CVC management in patients with major burn injuries. Forty-two burn patients with major burn injuries were randomly assigned to undergo site change every 48 hours of the CVC or to undergo wire guide exchange of the CVC every 48 hours at the same site. Catheter insertion site, distance from the burn wound, cultures of catheter tips, and blood cultures were obtained from all patients in a prospective manner. There was no difference in the incidence of CVC sepsis between the two groups studied. CVCs inserted less than 5 cm from the burn wound developed bacterial contamination at an earlier time than CVCs inserted more than 5 cm from the burn wound. There was no advantage to changing the CVC insertion site every 48 hours. Changing the CVC using the wire guide technique did not prevent, nor predict, CVC bacterial contamination.
Jauch, K. W.; Schregel, W.; Stanga, Z.; Bischoff, S. C.; Braß, P.; Hartl, W.; Muehlebach, S.; Pscheidl, E.; Thul, P.; Volk, O.
2009-01-01
Catheter type, access technique, and the catheter position should be selected considering to the anticipated duration of PN aiming at the lowest complication risks (infectious and non-infectious). Long-term (>7–10 days) parenteral nutrition (PN) requires central venous access whereas for PN <3 weeks percutaneously inserted catheters and for PN >3 weeks subcutaneous tunnelled catheters or port systems are appropriate. CVC (central venous catheter) should be flushed with isotonic NaCl solution before and after PN application and during CVC occlusions. Strict indications are required for central venous access placement and the catheter should be removed as soon as possible if not required any more. Blood samples should not to be taken from the CVC. If catheter infection is suspected, peripheral blood-culture samples and culture samples from each catheter lumen should be taken simultaneously. Removal of the CVC should be carried out immediately if there are pronounced signs of local infection at the insertion site and/or clinical suspicion of catheter-induced sepsis. In case PN is indicated for a short period (max. 7–10 days), a peripheral venous access can be used if no hyperosmolar solutions (>800 mosm/L) or solutions with a high titration acidity or alkalinity are used. A peripheral venous catheter (PVC) can remain in situ for as long as it is clinically required unless there are signs of inflammation at the insertion site. PMID:20049083
Carter, Eileen J; Pallin, Daniel J; Mandel, Leslie; Sinnette, Corine; Schuur, Jeremiah D
2016-02-01
Existing knowledge of emergency department (ED) catheter-associated urinary tract infection (CAUTI) prevention is limited. We aimed to describe the motivations, perceived risks for CAUTI acquisition, and strategies used to address CAUTI risk among EDs that had existing CAUTI prevention programs. In this qualitative comparative case study, we enrolled early-adopting EDs, that is, those using criteria for urinary catheter placement and tracking the frequency of catheters placed in the ED. At 6 diverse facilities, we conducted 52 semistructured interviews and 9 focus groups with hospital and ED participants. All ED CAUTI programs originated from a hospitalwide focus on CAUTI prevention. Staff were motivated to address CAUTI because they believed program compliance improved patient care. ED CAUTI prevention was perceived to differ from CAUTI prevention in the inpatient setting. To identify areas of ED CAUTI prevention focus, programs examined ED workflow and identified 4 CAUTI risks: (1) inappropriate reasons for urinary catheter placement; (2) physicians' limited involvement in placement decisions; (3) patterns of urinary catheter overuse; and (4) poor insertion technique. Programs redesigned workflow to address risks by (1) requiring staff to specify the medical reason for catheter at the point of order entry and placement; (2) making physicians responsible for determining catheter use; (3) using catheter alternatives to address patterns of overuse; and (4) modifying urinary catheter insertion practices to ensure proper placement. Early-adopting EDs redesigned workflow to minimize catheter use and ensure proper insertion technique. Assessment of ED workflow is necessary to identify and modify local practices that may increase CAUTI risk.
Lim, Woo Hyeon; Park, Chang Min; Yoon, Soon Ho; Lim, Hyun-Ju; Hwang, Eui Jin; Lee, Jong Hyuk; Goo, Jin Mo
2018-03-01
To evaluate the time-dependent incidence, risk factors and clinical significance of percutaneous lung biopsy (PLB)-related pneumothorax. From January 2012-November 2015, 3,251 patients underwent 3,354 cone-beam CT-guided PLBs for lung lesions. Cox, logistic and linear regression analyses were performed to identify time-dependent risk factors of PLB-related pneumothorax, risk factors of drainage catheter insertion and those of prolonged catheter placement, respectively. Pneumothorax occurred in 915/3,354 PLBs (27.3 %), with 230/915 (25.1 %) occurring during follow-ups. Risk factors for earlier occurrence of PLB-related pneumothorax include emphysema (HR=1.624), smaller target (HR=0.922), deeper location (HR=1.175) and longer puncture time (HR=1.036), while haemoptysis (HR=0.503) showed a protective effect against earlier development of pneumothorax. Seventy-five cases (8.2 %) underwent chest catheter placement. Mean duration of catheter placement was 3.2±2.0 days. Emphysema (odds ratio [OR]=2.400) and longer puncture time (OR=1.053) were assessed as significant risk factors for catheter insertion, and older age (parameter estimate=1.014) was a predictive factor for prolonged catheter placement. PLB-related pneumothorax occurred in 27.3 %, of which 25.1 % developed during follow-ups. Smaller target size, emphysema, deeply-located lesions were significant risk factors of PLB-related pneumothorax. Emphysema and older age were related to drainage catheter insertion and prolonged catheter placement, respectively. • One-fourth of percutaneous lung biopsy (PLB)-related pneumothorax occurs during follow-up. • Smaller, deeply-located target and emphysema lead to early occurrence of pneumothorax. • Emphysema is related to drainage catheter insertion for PLB-related pneumothorax. • Older age may lead to prolonged catheter placement for PLB-related pneumothorax. • Tailored management can be possible with time-dependent information of PLB-related pneumothorax.
Psychological reactions to continuous ambulatory peritoneal dialysis.
Geiser, M T; Van Dyke, C; East, R; Weiner, M
The first twenty patients who entered our continuous ambulatory peritoneal dialysis (CAPD) program from March, 1979 to February, 1981 were interviewed to assess their psychological reactions to CAPD. Six patients were successfully maintained on CAPD for more than one year. CAPD provided patients with a greater sense of well-being, strength, and independence. This independence required adherence to a strict schedule of exchanges. Reactions to the loss of CAPD followed the pattern of a grief reaction. Those patients who were self-disciplined and comfortable assuming active control of their health care proved to be the best candidates for CAPD.
Pua, Uei
2014-10-01
Central venous perforation during dialysis catheter insertion is a potentially fatal complication. Prompt recognition and judicious initial steps are important in optimizing the outcome. The purpose of this manuscript is to illustrate the imaging features and steps in initial management. © 2014 International Society for Hemodialysis.
Vaidyanathan, Subramanian; Soni, Bakul M; Oo, Tun; Hughes, Peter L; Singh, Gurpreet
2014-01-01
Autonomic dysreflexia is poorly recognised outside of spinal cord injury centres, and may result in adverse outcomes including mortality from delayed diagnosis and treatment. We present a spinal cord injury patient, who developed autonomic dysreflexia following incorrect placement of urethral Foley catheter. Health professionals failed to recognise signs and symptoms of autonomic dysreflexia as well as its significance in this tetraplegic patient. A tetraplegic patient started sweating profusely following insertion of a Foley catheter per urethra. The catheter was draining urine; there was no bypassing, no bleeding per urethra, and no haematuria. Patient's wife, who had been looking after her tetraplegic husband for more than forty years, told the health professionals that the catheter might have been placed incorrectly but her concerns were ignored. Ultrasound scan of urinary tract revealed no urinary calculi, no hydronephrosis. The balloon of Foley catheter was not seen in urinary bladder but this finding was not recognised by radiologist and spinal cord physician. Patient continued to sweat profusely; therefore, CT of pelvis was performed, but there was a delay of ten days. CT revealed the balloon of Foley catheter in the over-stretched prostate-membranous urethra; the tip of catheter was not located within the urinary bladder but was lying distal to bladder neck. Flexible cystoscopy was performed and Foley catheter was inserted into the bladder over a guide wire. The intensity of sweating decreased; noxious stimuli arising from traumatised urethra might take a long while to settle. Inserting a catheter in a tetraplegic patient should be carried out by a senior health professional, who is familiar with spasm of bladder neck which occurs frequently in tetraplegic patients. Facilities for urgent CT scan should be available to check the position of Foley catheter in spinal cord injury patients when a patient manifests signs and symptoms of autonomic dysreflexia following insertion of a urethral catheter. When an isolated symptom such as flushing or sweating is noticed in a tetraplegic patient, doctors should seek out other signs/symptoms of autonomic dysreflexia.
A pilot study to assess adductor canal catheter tip migration in a cadaver model.
Leng, Jody C; Harrison, T Kyle; Miller, Brett; Howard, Steven K; Conroy, Myles; Udani, Ankeet; Shum, Cynthia; Mariano, Edward R
2015-04-01
An adductor canal catheter may facilitate early ambulation after total knee arthroplasty, but there is concern over preoperative placement since intraoperative migration of catheters may occur from surgical manipulation and result in ineffective analgesia. We hypothesized that catheter type and subcutaneous tunneling may influence tip migration for preoperatively inserted adductor canal catheters. In a male unembalmed human cadaver, 20 catheter insertion trials were divided randomly into one of four groups: flexible epidural catheter either tunneled or not tunneled; or rigid stimulating catheter either tunneled or not tunneled. Intraoperative patient manipulation was simulated by five range-of-motion exercises of the knee. Distance and length measurements were performed by a blinded regional anesthesiologist. Changes in catheter tip to nerve distance (p = 0.225) and length of catheter within the adductor canal (p = 0.467) were not different between the four groups. Two of five non-tunneled stimulating catheters (40 %) were dislodged compared to 0/5 in all other groups (p = 0.187). A cadaver model may be useful for assessing migration of regional anesthesia catheters; catheter type and subcutaneous tunneling may not affect migration of adductor canal catheters based on this preliminary study. However, future studies involving a larger sample size, actual patients, and other catheter types are warranted.
Lim, S H; Smith, M P; Machin, S J; Goldstone, A H
1993-01-01
In all, 88 patients with haematological malignancies requiring Hickman catheters for intensive chemotherapy were randomized to receive either one single bolus intravenous injection of teicoplanin, 400 mg, or no teicoplanin immediately before insertion of a double-lumen Hickman catheter. Lower incidences of catheter-related Gram-positive sepsis were recorded in patients receiving prophylactic teicoplanin; exit site infection, tunnel infection and catheter-related Gram-positive septicaemia were all reduced. The benefit of prophylactic teicoplanin was observed particularly among patients who were already neutropenic at the time of catheterization. All Gram-positive organisms isolated from infected skin sites or from blood cultures taken from Hickman catheters were susceptible to teicoplanin. No adverse reaction was reported in any of the patients receiving prophylaxis. Prophylactic teicoplanin, therefore, may be used routinely for patients requiring insertion of Hickman catheters for intensive chemotherapy, to reduce the early incidence of catheter-related sepsis, particularly during the period of neutropenia following chemotherapy.
Lim, S H; Smith, M P; Salooja, N; Machin, S J; Goldstone, A H
1991-07-01
Eighty-eight patients with haematological malignancies requiring Hickman catheters for intensive chemotherapy were randomized to receive either one single bolus intravenous injection of teicoplanin or no teicoplanin immediately before insertion of a double lumen Hickman catheter. There were lower incidences of catheter-related Gram-positive sepsis in patients receiving prophylactic teicoplanin. There were less exit site infections, tunnel infections and catheter-related Gram-positive septicaemia. The benefit of prophylactic teicoplanin was observed especially among patients who were already neutropenic at the time of catheterization. All Gram-positive organisms isolated from the infected skin sites or from blood cultures taken from the Hickman catheters were sensitive to teicoplanin. No adverse reaction was reported in any of the patients in the prophylactic group. Prophylactic teicoplanin therefore may be used routinely for patients requiring insertion of Hickman catheters for intensive chemotherapy to reduce the early incidence of catheter-related sepsis, especially during the associated period of neutropenia following chemotherapy.
[Tension haemothorax after removal of pleural pigtail catheter].
Siegel, Hanna; Lauritsen, Anne Øberg
2014-07-07
Today, standard treatment of pleural effusion is ultrasound guided insertion of a pleural pigtail catheter. This procedure is known to have a low complication rate, but complications as pneumothorax, haemorrhage and infection are occurring. The most frequent complications are seen at the time of insertion. We present a case of a 68-year-old woman in the intensive care unit with normal coagulation status who after an uneventful removal of a pleural pigtail catheter developed a tension haemothorax requiring acute evacuation.
Ferrokinetics in Patients on CAPD: Influence of CAPD on the Anemia of Uremia*
Lee, Hi Bahl; Koh, Seong Won; Park, Hee Sook
1986-01-01
Ferrokinetic studies were performed with 59Fe-citrate to evaluate erythropoietic activity in CAPD patients and to investigate the mechanism(s) by which the hematocrit increases in CAPD patients. Plasma iron disappearance rate (PID), plasma iron turnover rate (PIT), red cell iron utilization (RCIU), red cell iron turnover rate (RCIT) and marrow transit time (MTT) were all “normal” in uremic patients not yet on dialysis (Hct 23.8±3.4%), CAPD patients with persistently low hematocrit (Hct 24.9±1.8%) and CAPD patients with improved hematocrit (Hct 32.4±3.1%). Compared to these uremic patients, patients with iron deficiency anemia and normal renal function (Hct 28.0±5.1 %) had significantly faster PID and MTT and significantly higher RCIU and RCIT. Plasma volume was significantly reduced (to normal level) in CAPD patients with improved hematocrits. The results of this study suggest that erythropoietic activity is inadequate for the degree of anemia in CAPD patients as well as uremic patients not on dialysis and further suggest that the hematocrit increases in CAPD as a result of decreased plasma volume. PMID:15759377
Johnston, Andrew J; Streater, Carmel T; Noorani, Remy; Crofts, Joanne L; Del Mundo, Aldwin B; Parker, Richard A
2012-01-01
Peripherally Inserted Central Catheters (PICCs) are increasingly being used to provide short to medium-term central venous access. The current study was designed to test the hypothesis that PICC valve technology does not influence PICC occlusion rates. Intensive care unit (ICU) patients who required a PICC were randomized to one of three types of dual lumen PICC (open ended non-valved, Groshong valve, PASV valve). PICC occlusions were recorded and managed with a protocol that used urokinase. A total of 102 patients were recruited to the study. The overall risk of occlusion per catheter was 35% (95% CI 26% to 44%). The overall rate of occlusion was 76 occlusions per 1000 catheter days (95% CI 61 to 95). Presence or type of valve did not significantly influence this rate (open-ended non-valved PICC 38% of catheters, 79 occlusions per 1000 catheter days; Groshong 38% of catheters, 60 occlusions per 1000 catheter days; PASV 27% of catheters, 99 occlusions per 1000 catheter days). The dose of urokinase required to treat PICC occlusions did not significantly differ between PICC types. Valved PICCs do not appear to influence PICC occlusion rates.
Verrina, E; Edefonti, A; Bassi, S; Perfumo, F; Zacchello, G; Andreetta, B; Caringella, D; Lavoratti, G; Picca, M; Rinaldi, S
1992-01-01
During the period 1986-1990, 119 patients were enrolled in the Italian Registry of Pediatric CPD. CAPD was largely predominant in the first 3 years, while CCPD accounted for 48% of dialysis months in the period 1989-1990. The connect-disconnect system was a Y set for all patients during the whole observation period. The incidence of peritonitis decreased from 1 episode: 10.9 patient-months in 1986 to 1:19.8 in 1988, and then passed to 1:16.2 in 1990. A comparison of the incidence of peritonitis between CAPD and CCPD, referring to the 1989-1990 period, showed no significant difference. The percentage of positive peritoneal fluid cultures changed from 48% in 1986 to 73% in 1990. Gram-positive bacteria, primarily Staphylococcus aureus and Staphylococcus epidermidis, accounted for most of the isolated organisms. Candida albicans was cultured in 3 cases both in 1986 and 1987. Exit site infection was the predominant (82%) complication, followed by leakage and catheter cuff extrusion. The hospitalization rate for peritonitis resulted persistently high (61% of episodes) and the mean duration was 12.7 days. Of the 8 patients who were switched to hemodialysis, 4 had recurrent peritonitis and 1 Candida albicans peritonitis.
Amir, Rabia; Knio, Ziyad O; Mahmood, Feroze; Oren-Grinberg, Achikam; Leibowitz, Akiva; Bose, Ruma; Shaefi, Shahzad; Mitchell, John D; Ahmed, Muneeb; Bardia, Amit; Talmor, Daniel; Matyal, Robina
2017-07-01
Although real-time ultrasound guidance during central venous catheter insertion has become a standard of care, postinsertion chest radiograph remains the gold standard to confirm central venous catheter tip position and rule out associated lung complications like pneumothorax. We hypothesize that a combination of transthoracic echocardiography and lung ultrasound is noninferior to chest radiograph when used to accurately assess central venous catheter positioning and screen for pneumothorax. All operating rooms and surgical and trauma ICUs at the institution. Single-center, prospective noninferiority study. Patients receiving ultrasound-guided subclavian or internal jugular central venous catheters. During ultrasound-guided central venous catheter placement, correct positioning of central venous catheter was accomplished by real-time visualization of the guide wire and positive right atrial swirl sign using the subcostal four-chamber view. After insertion, pneumothorax was ruled out by the presence of lung sliding and seashore sign on M-mode. Data analysis was done for 137 patients. Chest radiograph ruled out pneumothorax in 137 of 137 patients (100%). Lung ultrasound was performed in 123 of 137 patients and successfully screened for pneumothorax in 123 of 123 (100%). Chest radiograph approximated accurate catheter tip position in 136 of 137 patients (99.3%). Adequate subcostal four-chamber views could not be obtained in 13 patients. Accurate positioning of central venous catheter with ultrasound was then confirmed in 121 of 124 patients (97.6%) as described previously. Transthoracic echocardiography and lung ultrasound are noninferior to chest x-ray for screening of pneumothorax and accurate central venous catheter positioning. Thus, the point of care use of ultrasound can reduce central venous catheter insertion to use time, exposure to radiation, and improve patient safety.
Heudorf, Ursel; Grünewald, Miriam; Otto, Ulla
2016-01-01
The Commission for Hospital Hygiene and Infection Prevention (KRINKO) updated the recommendations for the prevention of catheter-associated urinary tract infections in 2015. This article will describe the implementation of these recommendations in Frankfurt's hospitals in autumn, 2015. In two non-ICU wards of each of Frankfurt's 17 hospitals, inspections were performed using a checklist based on the new KRINKO recommendations. In one large hospital, a total of 5 wards were inspected. The inspections covered the structure and process quality (operating instructions, training, indication, the placement and maintenance of catheters) and the demonstration of the preparation for insertion of a catheter using an empty bed and an imaginary patient, or insertion in a model. Operating instructions were available in all hospital wards; approximately half of the wards regularly performed training sessions. The indications were largely in line with the recommendations of the KRINKO. Alternatives to urinary tract catheters were available and were used more often than the urinary tract catheters themselves (15.9% vs. 13.5%). In accordance with the recommendations, catheters were placed without antibiotic prophylaxis or the instillation of antiseptic or antimicrobial substances or catheter flushing solutions. The demonstration of catheter placement was conscientiously performed. Need for improvement was seen in the daily documentation and the regular verification of continuing indication for a urinary catheter, as well as the omission of regular catheter change. Overall, the recommendations of the KRINKO on the prevention of catheter-associated urinary tract infections were adequately implemented. However, it cannot be ruled out that in situations with time pressure and staff shortage, the handling of urinary tract catheters may be of lower quality than that observed during the inspections, when catheter insertion was done by two nurses. Against this background, a sufficient number of qualified staff and regular ward rounds by the hygiene staff appear recommendable.
Junqueira, Beatriz L P; Connolly, Bairbre; Abla, Oussama; Tomlinson, George; Amaral, Joao G
2010-09-15
The objective of this study was to determine whether severe neutropenia on the day of port-a-catheter (PORT) insertion was a risk factor for catheter-associated infection (CAI) in children with acute lymphoblastic leukemia (ALL). This was a retrospective study of children with ALL who had a PORT insertion between January 2005 and August 2008. Early (≤ 30 days) and late (>30 days) postprocedure complications were reviewed. The length of follow-up ranged between 7 months and 42 months. In total, 192 PORTs were inserted in 179 children. There were 43 CAIs (22%), and the infection rate was 0.35 per 1000 catheter-days. The CAI rate (15%) in children who had severe neutropenia on the day of the procedure did not differ statistically from the CAI rate (24%) in children who did not have severe neutropenia (P = .137). Conversely, patients with severe neutropenia who had a CAI were more likely to have their PORT removed (P = .019). The most common organisms to cause catheter removal were coagulase-negative Staphylococcus and Staphylococcus aureus. Patients with high-risk ALL had a statistically significant higher incidence of late CAI than patients with standard-risk ALL (P = .012). Age (P = .272), positive blood culture preprocedure (P = 1.0), and dexamethasone use (P = .201) were not risk factors for CAI. Patients who had an early CAI did not have a greater chance of having a late CAI. The catheter infection-free survival rate at 1 year was 88.6%. The current results indicated that severe neutropenia on the day of PORT insertion does not increase the risk of CAI in children with ALL. © 2010 American Cancer Society.
Modified Peritoneal Dialysis Catheter Insertion: Comparison with a Conventional Method.
Lee, Yong Kyu; Yang, Pil-Sung; Park, Kyoung Sook; Choi, Kyu Hun; Kim, Beom Seok
2015-07-01
The conventional trocar and cannula method in peritoneal dialysis (PD) catheter insertion has its limitation in clinical setting. The aim of this study was to compare a modified method for percutaneous PD catheter insertion with the conventional method, and demonstrate advantages of the modified method. Patients at a single center who had percutaneous PD catheters inserted by nephrologists from January 2006 until September 2012, using either a modified method (group M) or the conventional trocar and cannula method (group C), were retrospectively analyzed, in terms of baseline characteristics, complications experienced up to 3 months after the procedure, and the suitability of the procedure for patients. Group M included 82 subjects, while group C included 66 cases. The overall early complication rate in group M (1.2%) was significantly lower than that in group C (19.7%) (p<0.001). The catheter revision rate during timeframe for early complications was significantly lower in group M (0%) than in group C (6.1%) (p=0.024). When comparing Procedure time (1 h 3 min±16 min vs. 1 h 36 min±19 min, p<0.01), immediate post-procedural pain (2.43±1.80 vs. 3.14±2.07, p<0.05), and post-procedure days until ambulation (3.95±1.13 days vs. 6.17±1.34 days, p<0.01), group M was significantly lower than group C. There was no significant difference in total hospitalization period (14.71±7.05 days vs. 13.86±3.7 days). Our modified PD catheter insertion method shows its advantages in early complication rate, early complications revision rate, and the patients' conveniences.
Modified Peritoneal Dialysis Catheter Insertion: Comparison with a Conventional Method
Lee, Yong Kyu; Yang, Pil-Sung; Park, Kyoung Sook; Choi, Kyu Hun
2015-01-01
Purpose The conventional trocar and cannula method in peritoneal dialysis (PD) catheter insertion has its limitation in clinical setting. The aim of this study was to compare a modified method for percutaneous PD catheter insertion with the conventional method, and demonstrate advantages of the modified method. Materials and Methods Patients at a single center who had percutaneous PD catheters inserted by nephrologists from January 2006 until September 2012, using either a modified method (group M) or the conventional trocar and cannula method (group C), were retrospectively analyzed, in terms of baseline characteristics, complications experienced up to 3 months after the procedure, and the suitability of the procedure for patients. Results Group M included 82 subjects, while group C included 66 cases. The overall early complication rate in group M (1.2%) was significantly lower than that in group C (19.7%) (p<0.001). The catheter revision rate during timeframe for early complications was significantly lower in group M (0%) than in group C (6.1%) (p=0.024). When comparing Procedure time (1 h 3 min±16 min vs. 1 h 36 min±19 min, p<0.01), immediate post-procedural pain (2.43±1.80 vs. 3.14±2.07, p<0.05), and post-procedure days until ambulation (3.95±1.13 days vs. 6.17±1.34 days, p<0.01), group M was significantly lower than group C. There was no significant difference in total hospitalization period (14.71±7.05 days vs. 13.86±3.7 days). Conclusion Our modified PD catheter insertion method shows its advantages in early complication rate, early complications revision rate, and the patients' conveniences. PMID:26069120
Davenport, Andrew
2009-01-01
Over the past two decades, the rate of peritonitis in patients treated by peritoneal dialysis (PD) has been significantly reduced. However, peritonitis remains a major complication of PD, accounting for considerable mortality and hospitalization among PD patients. To compare the outcome of peritonitis in a large unselected group of PD patients with that from single-center and selected groups. We audited the outcome of peritonitis in PD patients attending the 12 PD units in the Thames area in 2002 and 2003. There were 538 patients on continuous ambulatory PD (CAPD) and 325 patients on automated PD (APD) and/or continuous cycling PD (CCPD) at the end of 2002, and 635 CAPD and 445 APD/CCPD patients at the end of 2003. There were 1467 episodes of PD peritonitis during the 2-year period, including 129 recurrent episodes, with the average number of months between peritonitis episodes being 14.7 for CAPD and 18.1 for APD/CCPD, p < 0.05. However there was considerable variation between units. Coagulase-negative staphylococcus (CoNS) was the most common cause, accounting for around 30% of all peritonitis episodes, including recurrences, followed by non-pseudomonas gram negatives and Staphylococcus aureus. Cure rates were 77.2% for CoNS, 46.6% for S. aureus, and 7.7% for methicillin-resistant S. aureus. The cure rate for pseudomonas was 21.4%, and other gram negatives 56.7%. In total, there were 351 episodes of culture-negative peritonitis, with an average cure rate of 76.9%. Cure rates were higher for those centers that used a combination of intraperitoneal gentamicin and cephalosporins than those centers that used oral-based regimes. A total of 296 PD catheters were removed as a direct consequence of PD peritonitis: 121 due to gram-positive and 123 due to gram-negative organisms. Only 49 catheters were reinserted and the patients returned to PD. 52 patients died during or subsequent to their episode of PD peritonitis, with an overall mortality rate of 3.5%. This audit showed that, in a large unselected population of PD patients, the incidence of peritonitis was significantly greater than that reported in single-center short-term studies, and varied from unit to unit. Similarly, the success of treating PD peritonitis varied not only with the cause of the infection but also from unit to unit. PD peritonitis remains a major cause of patients discontinuing PD and switching to hemodialysis.
Pelloux, Sophie; Grégoire, Arnaud; Kirmizigul, Patrice; Maillot, Sandrine; Bui-Xuan, Bernard; Llorca, Guy; Boet, Sylvain; Lehot, Jean-Jacques; Rimmelé, Thomas
2017-12-01
Peripheral venous catheter insertion is a procedural skill that every medical student should master. Training is often limited to a small number of students and is poorly evaluated. The objective of this study was to evaluate the performance of peer-assisted learning in comparison to instructor-led teaching for peripheral venous catheter insertion training. Students were randomized to the control group attending a traditional instructor-led training session (slideshow and demonstration by an anesthetist instructor, followed by training on a procedural simulator) or to the test group attending a peer-assisted training session (slideshow and demonstration video-recorded by the same instructor, followed by training on a procedural simulator). The primary endpoint was the performance of peripheral venous catheter insertion, assessed on procedural simulator one week later by blinded experts using a standardized 20-item grid. Students self-evaluated their confidence levels using a numeric 10-point scale. Eighty-six students were included, 73 of whom attended the assessment session. The median performance score was 12/20 [8-15] in the instructor-led teaching group versus 13/20 [11-15] in the peer-assisted learning group (P=0.430). Confidence levels improved significantly after the assessment session and were significantly higher in the peer-assisted learning group (7.6/10 [7.0-8.0] versus 7.0/10 [5.0-8.0], P=0.026). Peer-assisted learning is effective for peripheral venous catheter insertion training and can be as effective as instructor-led teaching. Given the large number of students to train, this finding is important for optimizing the cost-effectiveness of peripheral venous catheter insertion training. Copyright © 2017 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.
Success of Urgent-Start Peritoneal Dialysis in a Large Canadian Renal Program
Alkatheeri, Ali M.A.; Blake, Peter G.; Gray, Daryl; Jain, Arsh K.
2016-01-01
♦ Background: Many patients start renal replacement therapy urgently on in-center hemodialysis via a central venous catheter, which is considered suboptimal. An alternative approach to manage these patients is to start them on peritoneal dialysis (PD). In this report, we describe the first reported Canadian experience with an urgent-start PD program. Additionally we reviewed the literature in this area. ♦ Methods: In this prospective observational study, we report on our experience in a single academic center. This program started in July 2010. We included patients who initiated PD urgently, that is within 2 weeks of catheter insertion. We followed all incident PD patients until October 2013 for mechanical and infectious complications. Peritoneal dialysis catheters were inserted either percutaneously or laparoscopically and dialysis was initiated in either an inpatient or outpatient setting. ♦ Results: Thirty patients were started on urgent PD during our study period. Follow-up ranged from 28 to 1,050 days. Twenty insertions (66.7 %) were done percutaneously and 10 (33.3%) were laparoscopic. Dialysis was initiated within 2 weeks (range: 0 – 13 days, median = 6 days). Twenty-four patients (80%) started PD in an outpatient setting and 6 patients (20%) required immediate inpatient PD start. Three patients (10%) developed a minor peri-catheter leak during the first week of training that was managed conservatively. There were no episodes of peritonitis or exit-site/tunnel infection during the first 4 weeks post-insertion. Four patients (13.3 %) from the percutaneous insertion group and 2 patients (6.7%) from laparoscopic insertions developed catheter dysfunction due to migration, which was managed by repositioning, without need for catheter replacement or modality switch. ♦ Conclusions: Our results are consistent with other studies in this area and demonstrate that urgent-start PD is an acceptable and safe alternative to hemodialysis in patients who need to start dialysis urgently without established dialysis access. PMID:26374834
Success of Urgent-Start Peritoneal Dialysis in a Large Canadian Renal Program.
Alkatheeri, Ali M A; Blake, Peter G; Gray, Daryl; Jain, Arsh K
2016-01-01
♦ Many patients start renal replacement therapy urgently on in-center hemodialysis via a central venous catheter, which is considered suboptimal. An alternative approach to manage these patients is to start them on peritoneal dialysis (PD). In this report, we describe the first reported Canadian experience with an urgent-start PD program. Additionally we reviewed the literature in this area. ♦ In this prospective observational study, we report on our experience in a single academic center. This program started in July 2010. We included patients who initiated PD urgently, that is within 2 weeks of catheter insertion. We followed all incident PD patients until October 2013 for mechanical and infectious complications. Peritoneal dialysis catheters were inserted either percutaneously or laparoscopically and dialysis was initiated in either an inpatient or outpatient setting. ♦ Thirty patients were started on urgent PD during our study period. Follow-up ranged from 28 to 1,050 days. Twenty insertions (66.7%) were done percutaneously and 10 (33.3%) were laparoscopic. Dialysis was initiated within 2 weeks (range: 0-13 days, median = 6 days). Twenty-four patients (80%) started PD in an outpatient setting and 6 patients (20%) required immediate inpatient PD start. Three patients (10%) developed a minor peri-catheter leak during the first week of training that was managed conservatively. There were no episodes of peritonitis or exit-site/tunnel infection during the first 4 weeks post-insertion. Four patients (13.3%) from the percutaneous insertion group and 2 patients (6.7%) from laparoscopic insertions developed catheter dysfunction due to migration, which was managed by repositioning, without need for catheter replacement or modality switch. ♦ Our results are consistent with other studies in this area and demonstrate that urgent-start PD is an acceptable and safe alternative to hemodialysis in patients who need to start dialysis urgently without established dialysis access. Copyright © 2016 International Society for Peritoneal Dialysis.
21 CFR 868.5350 - Nasal oxygen catheter.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...
21 CFR 868.5350 - Nasal oxygen catheter.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...
21 CFR 868.5350 - Nasal oxygen catheter.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...
21 CFR 868.5350 - Nasal oxygen catheter.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...
21 CFR 868.5350 - Nasal oxygen catheter.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nasal oxygen catheter. 868.5350 Section 868.5350...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5350 Nasal oxygen catheter. (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to...
Ranganathan, Dwarakanathan; John, George T; Yeoh, Edward; Williams, Nicola; O'Loughlin, Barry; Han, Thin; Jeyaseelan, Lakshmanan; Ramanathan, Kavitha; Healy, Helen
2017-01-01
The optimal time for the commencement of peritoneal dialysis (PD) after PD catheter insertion is unclear. If dialysis is started too soon after insertion, dialysate leaks and infection could occur. However, by starting PD earlier, morbidity and costs can be reduced through lesser hemodialysis requirements. This is the first randomized controlled trial to determine the safest and shortest interval to commence PD after catheter insertion. All consecutive patients undergoing PD catheter insertion at the Royal Brisbane and Women's Hospital and Rockhampton Hospital from 1 March 2008 to 31 May 2013 who met the inclusion and exclusion criteria were invited to participate in the trial. Participants were randomized to 1 of 3 groups. Group 1 (G1) commenced PD at 1 week, group 2 (G2) at 2 weeks and group 3 (G3) at 4 weeks after PD catheter insertion. These groups were stratified by hospital and the presence of diabetes. Primary outcomes were the incidence of peritoneal fluid leaks or PD-related infection during the 4 weeks after commencement of PD. In total 122 participants were recruited, 39, 42, and 41 randomized to G1, G2, and G3, respectively. The primary outcome catheter leak was significantly higher in G1 (28.2%) compared with G3 (2.4%, p = 0.001) but not compared with G2 (9.5%, p = 0.044), based on intention to treat analysis. These differences were even more marked when analyzed with per protocol method: G1 had a significantly higher percentage (32.4 %) compared with G3 (3.3%, p = 0.003) but not compared with G2 (10.5%, p = 0.040). Event percentages of leak were statistically higher in G1 and occurred significantly earlier compared with other groups ( p = 0.002). Amongst diabetics, technique failure was significantly higher (28.6%) in G3 compared with 0% in G1 and 7.1% in G2 ( p = 0.036) and earlier in G3 at 163.2 days vs 176.8 and 175.8 ( p = 0.037) for G1 and G2, respectively. Leaks were higher in participants commencing PD at 1 week after catheter insertion compared with the other 2 groups, and technique failure was higher in diabetics starting PD at 4 weeks. Copyright © 2017 International Society for Peritoneal Dialysis.
Effectiveness of electrocardiographic guidance in CVAD tip placement.
Walker, Graham; Chan, Raymond J; Alexandrou, Evan; Webster, Joan; Rickard, Claire
International standard practice for the correct confirmation of the central venous access device is the chest X-ray. The intracavitary electrocardiogram-based insertion method is radiation-free, and allows real-time placement verification, providing immediate treatment and reduced requirement for post-procedural repositioning. Relevant databases were searched for prospective randomised controlled trials (RCTs) or quasi RCTs that compared the effectiveness of electrocardiogram-guided catheter tip positioning with placement using surface-anatomy-guided insertion plus chest X-ray confirmation. The primary outcome was accurate catheter tip placement. Secondary outcomes included complications, patient satisfaction and costs. Five studies involving 729 participants were included. Electrocardiogram-guided insertion was more accurate than surface anatomy guided insertion (odds ratio: 8.3; 95% confidence interval (CI) 1.38; 50.07; p=0.02). There was a lack of reporting on complications, patient satisfaction and costs. The evidence suggests that intracavitary electrocardiogram-based positioning is superior to surface-anatomy-guided positioning of central venous access devices, leading to significantly more successful placements. This technique could potentially remove the requirement for post-procedural chest X-ray, especially during peripherally inserted central catheter (PICC) line insertion.
Safe percutaneous suprapubic catheterisation.
Goyal, N K; Goel, A; Sankhwar, S N
2012-11-01
We describe our technique of percutaneous suprapubic catheter insertion with special reference to steps that help to avoid common complications of haematuria and catheter misplacement. The procedure is performed using a stainless steel reusable trocar under local infiltrative anaesthesia, usually at the bedside. After clinical confirmation of a full bladder, the trocar is advanced into the bladder through a skin incision. Once the bladder is entered, the obturator is removed and the assistant inserts a Foley catheter followed by rapid balloon inflation. Slight traction is applied to the catheter for about five minutes. Patients with previous lower abdominal surgery, an inadequately distended bladder or acute pelvic trauma do not undergo suprapubic catheterisation using this method. The procedure was performed in 72 men (mean age: 42.4 years, range: 18-78 years) with urinary retention with a palpable bladder. The average duration of the procedure was less than five minutes. No complications were noted in any of the patients. Trocar suprapubic catheter insertion is a safe and effective bedside procedure for emergency bladder drainage and can be performed by resident surgeons. The common complications associated with the procedure can be avoided with a few careful steps.
Tcholakian, Robert K.; Raad, Issam I.
2001-01-01
This study was performed to test the long-term antimicrobial efficacy of impregnated silicone catheters comprising an antimicrobial layer sandwiched between an external surface sheath and a luminal surface silicone sheath. The design of the catheter permits the introduction of various antimicrobials in addition to anticoagulants or antifibrins in the antimicrobial layer and allows their gradual release over a period of months after insertion. The in vitro data presented show that the catheter can provide antimicrobial activity for 90 days, after being replated for 15 7-day cycles of replating. When the catheters were immersed in human serum and incubated at 37°C, they demonstrated significant antimicrobial activity after more than 325 days of incubation. The significant long-term in vitro antimicrobial activity observed may imply effective in vivo activity for almost 1 year after insertion and could serve as a cost-effective alternative to surgically implantable silicone catheters. PMID:11408213
Evaluating new technology to improve patient outcomes: a quality improvement approach.
McMahon, Dorthea D
2002-01-01
The nurses in the peripherally inserted central catheter (PICC) program at the University of Washington Medical Center perform ongoing data tracking to measure team and patient outcomes. Quality improvement initiatives have included the transition to microintroducer technology and ultrasound-guided placement. Used together, this technology has allowed the PICC team to increase their bedside insertion success rate to 91%. The group has also changed PICC securement methods, and use of the Statlock anchoring device has reduced the incidence of catheter migration from 6% to 1.5% of all catheter lines placed. Catheter durability also was assessed. The Pressure Activated Safety Valve PICC was compared to the Groshong PICC and the rate of catheter repair and exchange due to breakage has been reduced from 11% to 1%.
A novel, inexpensive, double lumen suprapubic catheter for urodynamics.
Wagner, Andrew A; Godley, Margaret L; Duffy, Patrick G; Ransley, Philip G
2004-03-01
We describe a novel, double lumen, intravesical, suprapubic catheter designed to meet the requirements of pediatric urodynamics that is easy to use and has minimal complications. A commercially available 10Fr pediatric suprapubic pigtail catheter forms the outer lumen for instilling filling media. A 16 gauge epidural catheter is inserted through the outer catheter providing an inner lumen for measuring intravesical pressures. The resultant double-lumen catheter is inserted suprapubically using a peel away needle supplied with the 10Fr catheter, with the patient under general anesthetic. The catheter has been used for 15 years in more than 700 patients with good reliability and few complications. The concentric construction of the double lumens and the rigidity of the inner intravesical pressure channel ensure there is no transmission of pressure from the filling channel to the inner lumen. The catheter has a circular cross section and a pigtail distal end which help to retain it within the bladder. There is low resistance to filling that allows adequate filling rates to be achieved by gravity rather than necessitating a pump. The catheter is easily made from readily available components and is less expensive than other double-lumen catheters suitable for suprapubic use. A reliable, double lumen catheter that fulfills criteria not found in commercially available alternatives can be inexpensively made for urodynamics.
Weihing, Jeffrey; Guenette, Linda; Chermak, Gail; Brown, Mallory; Ceruti, Julianne; Fitzgerald, Krista; Geissler, Kristin; Gonzalez, Jennifer; Brenneman, Lauren; Musiek, Frank
2015-01-01
Although central auditory processing disorder (CAPD) test battery performance has been examined in adults with neurologic lesions of the central auditory nervous system (CANS), similar data on children being referred for CAPD evaluations are sparse. This study characterizes CAPD test battery performance in children using tests commonly administered to diagnose the disorder. Specifically, this study describes failure rates for various test combinations, relationships between CAPD tests used in the battery, and the influence of cognitive function on CAPD test performance and CAPD diagnosis. A comparison is also made between the performance of children with CAPD and data from patients with neurologic lesions of the CANS. A retrospective study. Fifty-six pediatric patients were referred for CAPD testing. Participants were administered four CAPD tests, including frequency patterns (FP), low-pass filtered speech (LPFS), dichotic digits (DD), and competing sentences (CS). In addition, they were given the Wechsler Intelligence Scale for Children (WISC). Descriptive analyses examined the failure rates of various test combinations, as well as how often children with CAPD failed certain combinations when compared with adults with CANS lesions. A principal components analysis was performed to examine interrelationships between tests. Correlations and regressions were conducted to determine the relationship between CAPD test performance and the WISC. Results showed that the FP and LPFS tests were most commonly failed by children with CAPD. Two-test combinations that included one or both of these two tests and excluded DD tended to be failed more often. Including the DD and CS test in a battery benefited specificity. Tests thought to measure interhemispheric transfer tended to be correlated. Compared with adult patients with neurologic lesions, children with CAPD tended to fail LPFS more frequently and DD less frequently. Both groups failed FP with relatively equal frequency. The two-test combination that showed the highest failure rate for children with CAPD was LPFS-FP. Comparison with adults with CANS lesions, however, suggests that the mechanisms underlying LPFS performance in children need to be better understood. The two-test combination that showed the next highest failure rates among children with CAPD and did not include LPFS was CS-FP. If it is desirable to use a dichotic measure that has a lower linguistic load than CS then DD can be substituted for CS despite the slightly lower failure rate of the DD-FP battery. American Academy of Audiology.
Lymphatic Leak Complicating Central Venous Catheter Insertion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barnacle, Alex M., E-mail: alexbarnacle@yahoo.co.uk; Kleidon, Tricia M.
2005-12-15
Many of the risks associated with central venous access are well recognized. We report a case of inadvertent lymphatic disruption during the insertion of a tunneled central venous catheter in a patient with raised left and right atrial pressures and severe pulmonary hypertension, which led to significant hemodynamic instability. To our knowledge, this rare complication is previously unreported.
Ferrete-Morales, C; Vázquez-Pérez, M A; Sánchez-Berna, M; Gilabert-Cerro, I; Corzo-Delgado, J E; Pineda-Vergara, J A; Vergara-López, S; Gómez-Mateos, J
2010-01-01
To assess the impact on the incidence of PPIVC by implementing a catheter management protocol and to determine risk factors for PPIVC development in hospitalized patients. A total of 3978 episodes of venous catheterization were prospectively included from September 2002 to December 2007. A catheter management protocol was implemented during this period of time. The incidence and variables associated to the occurrence of PPIVC were determined. The incidence of PPIVC from 2002 to 2007 was 4.8%, 4.3%, 3.6%, 2.5%, 1.3% and 1.8% (p<0.001). Perfusion of amiodarone [adjusted OR (AOR) 25.97; 95% CI=7.29-92.55, p=0.0001] and cefotaxime (AOR 2.90; 95% CI=1.29-6.52, p=0.01) and the shift when the catheters were placed (AOR for morning vs. night shift 0.60; 95% CI=0.35-1.02, p=0.063) were independently associated to the development of PPIVC. A history of phlebitis was the only factor independently associated to phlebitis due to peripherally inserted central venous catheters (AOR 3.24; CI at 95% CI= 1.05-9.98, p=0.04). A catheter management protocol decreases the incidence of PPIVC in hospitalized patients. The risk of PPIVC increases for peripherally inserted central venous catheters when the patients have a history of phlebitis and for peripheral venous catheters when amiodarone or cefotaxime are infused. Catheterization of peripheral veins performed during morning shifts is associated with a lower incidence of PPIVC when compared with night shift catheterizations.
Wang, Guorong; Guo, Ling; Jiang, Bin; Huang, Min; Zhang, Jian; Qin, Ying
2015-01-01
Amplitude changes in the P-wave of intracavitary electrocardiography have been used to assess the tip placement of central venous catheters. The research assessed the sensitivity and specificity of this sign in comparison with standard radiographic techniques for tip location, focusing on factors influencing its clinical utility. Both intracavitary electrocardiography guided tip location and X-ray positioning were used to verify catheter tip locations in patients undergoing central venous catheter insertion. Intracavitary electrocardiograms from 1119 patients (of a total 1160 subjects) showed specific amplitude changes in the P-wave. As the results show, compared with X-ray positioning, the sensitivity of electrocardiography-guided tip location was 97.3%, with false negative rate of 2.7%; the specificity was 1, with false positive rate of zero. Univariate analyses indicated that features including age, gender, height, body weight, and heart rate have no statistically significant influence on P-wave amplitude changes (P>0.05). Multivariate logistic regression revealed that catheter insertion routes (OR = 2.280, P = 0.003) and basal P-wave amplitude (OR = 0.553, P = 0.003) have statistically significant impacts on P-wave amplitude changes. As a reliable indicator of tip location, amplitude change in the P-wave has proved of good sensitivity and excellent specificity, and the minor, zero, false positive rate supports the clinical utility of this technique in early recognition of malpositioned tips. A better sensitivity was achieved in placement of centrally inserted central catheters (CICCs) than that of peripherally inserted central catheters (PICCs). In clinical practice, a combination of intracavitary electrocardiography, ultrasonic inspection and the anthropometric measurement method would further improve the accuracy. PMID:25915758
Complications of intra-cardial placement of silastic central venous catheter in pediatric patients.
Soong, W J; Jeng, M J; Hwang, B
1996-01-01
A three-year prospective study was undertaken to determine the incidence and early complications from intra-cardiac placement of percutaneous central venous catheter (CVC). CVC was inserted by using "Catheter-through-needle" technique, and the insertion length was measured by body surface landmark. CVC course and tip location were routinely checked by roentgenography. Echocardiography was performed in case of arrhythmia. After analysis of 784 CVCs, 104 (13.3%) were proved to be intra-cardial, as located by either roentgenography or echocardiography. However, catheters passed via the upper trunk (14.5%) were significantly (p < 0.05) more intra-cardially located than those via the lower trunk (4.8%). Catheters which passed via the right upper trunk veins (basilic, cephalic, or external jugular veins) were also more intra-cardially located than those via their left veins counterparts, but the finding was not statistically significant (p > 0.05). The mean body weight (3.1 +/- 2.4 kg) in the intra-cardial placement group was significantly (p < 0.05) less than that in the non-intracardial placement group (7.9 +/- 4.5 kg). In intra-cardial placement patients, 32 cases (30.8%) had episode(s) of cardiac arrhythmia including 31 premature ventricular depolarization and 1 supra-ventricular tachycardia. All cases showed the presence of intra-ventricular catheter. All arrhythmias ceased abruptly after the catheters were pulled from the hearts. No other early complications were observed. the incidence of the intracardiac placement of CVC is high, especially in small infants or when the insertion via the upper trunk. Short term intra-cardiac catheter placement has a benign clinical course except that the intraventricular catheter may cause arrhythmia. However, this kind of arrhythmia can be resolved spontaneously by withdrawing the catheter.
Diaz, Katrina; Kelly, Sean G; Smith, Barbara; Malani, Preeti N; Younger, John G
2012-02-01
Despite successful efforts to improve overall central line-associated bloodstream infections (CLABSI) rates, little is known about CLABSI rates or even central venous catheter insertion practices in the Emergency Department. We sought to determine the baseline CLABSI rate for Emergency Department-inserted central venous catheters and to describe indications for placement, duration of use, and the natural history of these devices. Copyright © 2012 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
Paravertebral block catheter breakage by electrocautery during thoracic surgery.
Saeki, Noboru; Sugimoto, Yuki; Mori, Yoko; Kato, Takahiro; Miyoshi, Hirotsugu; Nakamura, Ryuji; Koga, Tomomichi
2017-06-01
Advantages of thoracic paravertebral analgesia (TPA) include placement of the catheter closer to the surgical field; however, the catheter can become damaged during the operation. We experienced a case of intraoperative TPA catheter breakage that prompted us to perform an experiment to investigate possible causes. A 50-year-old male underwent a thoracoscopic lower lobectomy under general anesthesia with TPA via an intercostal approach. Following surgery, it was discovered that the catheter had become occluded, as well as cut and fused, so we reopened the incision and removed the residual catheter. From that experience, we performed an experiment to examine electrocautery-induced damage in normal (Portex™, Smith's Medical), radiopaque (Perifix SoftTip™, BBraun), and reinforced (Perifix FX™, BBraun) epidural catheters (n = 8 each). Chicken meat was penetrated by each catheter and then cut by electrocautery. In the normal group, breakage occurred in 8 and occlusion in 6 of the catheters, and in the radiopaque group breakage occurred in 8 and occlusion in 7. In contrast, breakage occurred in only 3 and occlusion in none in the reinforced group, with the 5 without breakage remaining connected only by the spring coil. Furthermore, in 7 of the reinforced catheters, electric arc-induced thermal damage was observed at the tip of the catheter. A TPA catheter for thoracic surgery should be inserted via the median approach, or it should be inserted after surgery to avoid catheter damage during surgery.
Wilson, Thomas J; Stetler, William R; Fletcher, Jeffrey J
2013-07-01
To compare cumulative complication rates of peripherally (PICC) and centrally (CICVC) inserted central venous catheters, including catheter-related large vein thrombosis (CRLVT), central line-associated bloodstream infection (CLABSI), and line insertion-related complications in neurological intensive care patients. Retrospective cohort study and detailed chart review for 431 consecutive PICCs and 141 CICVCs placed in patients under neurological intensive care from March 2008 through February 2010. Cumulative incidence of CRLVT, CLABSI, and line insertion-related complications were compared between PICC and CICVC groups. Risk factors for CRLVT including mannitol therapy during dwell time, previous history of venous thromboembolism, surgery longer than 1h during dwell time, and line placement in a paretic arm were also compared between groups. During the study period, 431 unique PICCs were placed with cumulative incidence of symptomatic thrombosis of 8.4%, CLABSI 2.8%, and line insertion-related complications 0.0%. During the same period, 141 unique CICVCs were placed with cumulative incidence of symptomatic thrombosis of 1.4%, CLABSI 1.4%, and line insertion-related complications 0.7%. There was a statistically significant difference in CRLVT with no difference in CLABSI or line insertion-related complications. In neurological critical care patients, CICVCs appear to have a better risk profile compared to PICCs, with a decreased risk of CRLVT. As use of PICCs in critical care patients increases, a prospective randomized trial comparing PICCs and CICVCs in neurological critical care patients is necessary to assist in choosing the appropriate catheter and to minimize risks of morbidity and mortality associated with central venous access. Copyright © 2012 Elsevier B.V. All rights reserved.
Merlino, Giovanni; Lorenzut, Simone; Romano, Giulio; Sommaro, Martina; Fontana, Augusto; Montanaro, Domenico; Valente, Mariarosaria; Gigli, Gian Luigi
2012-12-01
Restless legs syndrome (RLS) is common in end-stage renal disease (ESRD) patients undergoing hemodialysis (HD). A few studies so far have investigated RLS prevalence in ESRD patients undergoing continuous ambulatory peritoneal dialysis (CAPD). The aim of this study was to compare the prevalence, characteristics, consequences and predictors of RLS between HD and CAPD patients. We recruited 58 HD and 28 CAPD patients. A neurologist expert in sleep medicine performed RLS diagnosis during a face-to-face interview. The prevalence of RLS was slightly higher in HD than in CAPD patients (19 vs. 10.7%). RLS appeared after the onset of kidney complaint in HD patients; in contrast, in CAPD patients RLS preceded the occurrence of renal disease. Five HD patients reported that RLS symptoms occurred throughout the dialysis session. HD patients with RLS(+) had a higher mean number of HD sessions per week and a longer mean duration of HD session than the RLS(-) ones. Prevalence of females was significantly higher in CAPD patients with RLS(+) than in the RLS(-) ones. RLS frequently affects both HD and CAPD patients. RLS impaired sleep in both groups, but use of dopaminergic agents was uncommon in our sample. Dialysis schedule was associated with RLS in HD patients, while female sex was related to RLS in CAPD patients. Awareness concerning RLS identification and treatment in HD and CAPD patients is recommended.
Heart catheter cable and connector
NASA Technical Reports Server (NTRS)
Harrison, D. R.; Cota, F. L.; Sandler, H.
1972-01-01
Ultraminiature catheter cables that are stiff enough for intravenous insertion yet flexible at the tip, sterilizable, and economical are fabricated entirely from commercially available parts. Assembly includes air passageway for reference pressures and coaxial cable for transmission of signals from the tip of catheter.
Prophylactic teicoplanin during insertion of Hickman catheters.
Lim, S H; Smith, M P; Machin, S J; Goldstone, A H
1990-12-01
With the extensive use of Hickman catheters in patients requiring cytotoxic chemotherapy there is now a resurgence of Gram-positive septicaemia among these patients during the neutropenic periods. We are currently running a prospective randomized study of prophylactic teicoplanin during insertion of Hickman catheters to determine if it reduces the incidence of Gram-positive septicaemia. A total of 44 patients have completed the study (23 in the teicoplanin group and 21 in the control group). The diagnoses were: acute myelogenous leukaemia (13), non-Hodgkin's lymphoma (16), Hodgkin's disease (11), chronic granulocytic leukaemia (3) and acute lymphoblastic leukaemia (1). The number of days between insertion of Hickman catheters and the development of neutropenia was: teicoplanin group: mean 14.7, median 11, range 0-53; control group: mean 11.8, median 10, range 0-37. In the treated patients, there were four episodes of line-associated Gram-positive septicaemia and a total of four organisms were isolated. In the control group, 10 organisms were isolated from a total of nine episodes of line-associated Gram-positive septicaemia. The organisms were: coagulase-negative staphylococci (8), Streptococcus B, (1), Strep. faecalis (1), Strep. mitis (1), alpha streptococcus (1), diphtheriods (1) and Staphylococcus aureus (1). All organisms were sensitive to teicoplanin. No adverse reaction was observed in any patient. Prophylactic teicoplanin during insertion of Hickman catheters may therefore reduce the incidence of line-associated Gram-positive septicaemia in neutropenic patients.
Limb/trunk lean mass ratio as a risk factor for mortality in peritoneal dialysis patients.
Kang, Seok Hui; Park, Jong Won; Yoon, Kyung Woo; Do, Jun Young
2013-07-01
This study was performed to determine the clinical relevance of limb/trunk lean mass ratio (LTLM) in continuous ambulatory peritoneal dialysis (CAPD) patients. This retrospective cohort study included 534 CAPD patients. Body compositions were measured using a dual-energy X-ray absorptiometry apparatus. In males, the sensitivity and specificity for the diagnosis of sarcopenia were 70.3% and 85.9%, respectively. Respective values in females were 62.3% and 83.8%. The initial low LTLM tertile was associated with mortality in male CAPD patients and in female CAPD patients. Among patients who maintained CAPD for a year, the maintenance of low LTLM tertile was associated with mortality. LTLM is associated with other lean mass indices, nutritional status, and mortality in CAPD patients. Therefore, LTLM is a novel marker that is useful for the prediction of the nutritional status and mortality in patients with CAPD. Copyright © 2013 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.
Ahn, J H; Kim, I S; Yang, J H; Lee, I G; Seo, D H; Kim, S P
2017-02-01
The lower superior vena cava (SVC), near its junction with the right atrium (RA), is considered the ideal location for the central venous catheter tip to ensure proper function and prevent injuries. We determined catheter insertion depth with a new formula using the sternoclavicular joint and the carina as radiological landmarks, with a 1.5 cm safety margin. The accuracy of tip positioning with the radiological landmark-based technique (R) and Peres' formula (P) was compared using transoesophageal echocardiography. Real-time ultrasound-guided central venous catheter insertion was done through the right internal jugular or subclavian vein. Patients were randomly assigned to either the P group (n=93) or the R group (n=95). Optimal catheter tip position was considered to be within 2 cm above and 1 cm below the RA-SVC junction. Catheter tip position, abutment, angle to the vascular wall, and flow stream were evaluated on a bicaval view. The distance from the skin insertion point to the RA-SVC junction and determined depth of catheter insertion were more strongly correlated in the R group [17.4 (1.2) and 16.7 (1.5) cm; r=0.821, P<0.001] than in the P group [17.3 (1.2) and 16.4 (1.1) cm; r=0.517, P<0.001], with z=3.96 (P<0.001). More tips were correctly positioned in the R group than in the P group (74 vs 93%, P=0.001). Abutment, tip angle to the lateral wall >40°, and disrupted flow stream were comparable. Catheter tip position was more accurate with a radiological landmark-based technique than with Peres' formula. Clinical Trial Registry of Korea: https://cris.nih.go.kr/cris/index.jsp KCT0001937. © The Author 2017. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Laparoscopic versus Open Peritoneal Dialysis Catheter Insertion: A Meta-Analysis
Hagen, Sander M.; Lafranca, Jeffrey A.; Steyerberg, Ewout W.; IJzermans, Jan N. M.; Dor, Frank J. M. F.
2013-01-01
Background Peritoneal dialysis is an effective treatment for end-stage renal disease. Key to successful peritoneal dialysis is a well-functioning catheter. The different insertion techniques may be of great importance. Mostly, the standard operative approach is the open technique; however, laparoscopic insertion is increasingly popular. Catheter malfunction is reported up to 35% for the open technique and up to 13% for the laparoscopic technique. However, evidence is lacking to definitely conclude that the laparoscopic approach is to be preferred. This review and meta-analysis was carried out to investigate if one of the techniques is superior to the other. Methods Comprehensive searches were conducted in MEDLINE, Embase and CENTRAL (the Cochrane Library 2012, issue 10). Reference lists were searched manually. The methodology was in accordance with the Cochrane Handbook for interventional systematic reviews, and written based on the PRISMA-statement. Results Three randomized controlled trials and eight cohort studies were identified. Nine postoperative outcome measures were meta-analyzed; of these, seven were not different between operation techniques. Based on the meta-analysis, the proportion of migrating catheters was lower (odds ratio (OR) 0.21, confidence interval (CI) 0.07 to 0.63; P = 0.006), and the one-year catheter survival was higher in the laparoscopic group (OR 3.93, CI 1.80 to 8.57; P = 0.0006). Conclusions Based on these results there is some evidence in favour of the laparoscopic insertion technique for having a higher one-year catheter survival and less migration, which would be clinically relevant. PMID:23457554
Current state of continuous ambulatory peritoneal dialysis in Egypt.
Elzorkany, Khaled Mohamed Amin
2017-01-01
Patients with end-stage renal disease (ESRD) continue to increase in number worldwide, especially in developing countries. Although continuous ambulatory peritoneal dialysis (CAPD) has comparable survival advantages as hemodialysis (HD), it is greatly underutilized in many regions worldwide. The prevalence of use of CAPD in Egypt is 0.29/million population in 2017. The aim of this study is to describe the current state and practice of CAPD in Egypt and included 22 adult patients who were treated by CAPD. All the study patients were switched to CAPD after treatment with HD failed due to vascular access problems. Patients were mainly female (68.2 %) with the mean age of 49.77 ± 11.41 years. The average duration on CAPD was 1.76 ± 1.30 years. Hypertension was the main cause of end-stage renal disease (ESRD) constituting 36.4%, followed by diabetes (27.3 %), and toxic nephropathy (4.5%). Of importance is that about 31.8% of patients had ESRD of unknown etiology. The mean weekly Kt/V urea of patients on PD was 1.92 ± 0.18. The mean hemoglobin, serum calcium, phosphorus, parathormone, and albumin levels were 10.27 ± 1.98 g/dL, 8.36 ± 1.19 mg/dL, 5.70 ± 1.35 mg/dL, 541.18 ± 230.12 pg/mL, and 2.98 ± 0.73 g/dL, respectively. There was no significant difference between diabetic and nondiabetic CAPD patients regarding demographic and laboratory data. Our data indicate that there is continuing underutilization of CAPD in Egypt which may be related to nonavailability of CAPD fluid, patient factors (education and motivation), gradual decline of the efficiency of health-care professionals, and lack of a national program to start PD as the first modality for renal replacement therapy. It is advised to start an organized program to make CAPD widespread and encourage local production of PD fluids to reduce the cost of CAPD.
Cortés-Sanabria, Laura; Paredes-Ceseña, Carlos A; Herrera-Llamas, Rebeca M; Cruz-Bueno, Yolanda; Soto-Molina, Herman; Pazarín, Leonardo; Cortés, Margarita; Martínez-Ramírez, Héctor R
2013-11-01
The use of automated peritoneal dialysis (APD) is increasing compared to continuous ambulatory peritoneal dialysis (CAPD). Surprisingly, little data about health benefits and cost of APD exist, and virtually no information comparing the cost-utility between CAPD and APD is available. We undertook this study to evaluate and compare the health-related quality of life (HRQOL) and cost-utility indexes in patients on CAPD vs. This was a prospective cohort of patients initiating dialysis (2008-2009). Two questionnaires were self-administered: European Research Questionnaire Quality of Life (EQ-5D) and Kidney Disease Quality of Life (short form, KDQOL-SF, Rand, Santa Monica, CA). Direct medical costs (DMC) were determined from the health provider perspective including the following medical resource utilization: outpatient clinic/emergency care, dialysis procedures, medications, laboratory tests, hospitalization, and surgery. Cost-utility indexes were calculated dividing total mean cost by indicators of the HRQOL. One hundred twenty-three patients were evaluated: 77 on CAPD and 46 on APD. Results of the EQ-5D and KDQOL-SF questionnaires were significantly better in APD compared to the CAPD group. Main costs in both APD and CAPD were attributed to hospitalization and dialysis procedures followed by medication and surgery. Outpatient clinic visits and laboratory tests were significantly more costly in CAPD than in APD, whereas dialysis procedures were more expensive in the latter. Cost-utility indexes were significantly better in APD compared to CAPD. A significant cost-utility advantage of APD vs. CAPD was observed. The annual DMC per-patient were not different between groups but the HRQOL was better in the APD compared to the CAPD group. Copyright © 2013 IMSS. Published by Elsevier Inc. All rights reserved.
Kim, Won Ho; Hong, Tae Hee; Byun, Joung Hun; Kim, Jong Woo; Kim, Sung Hwan; Moon, Sung Ho; Park, Hyun Oh; Choi, Jun Young; Yang, Jun Ho; Jang, In Seok; Lee, Chung Eun; Yun, Jeong Hee
In refractory cardiogenic shock, veno-arterial extracorporeal membrane oxygenation (ECMO) can be initiated. Although left heart decompression can be accomplished by insertion of a left atrial (LA) or left ventricular (LV) cannula using a percutaneous pigtail catheter, the venting flow rate according to catheter size and ECMO flow rate is unknown. We developed an artificial ECMO circuit. One liter saline bag with its pressure set to 20 mm Hg was connected to ECMO to mimic LV failure. A pigtail catheter was inserted into the 1 L saline bag to simulate LV unloading. For each pigtail catheter size (5-8 Fr) and ECMO flow rate (2.0-4.0 L/min), the moving distance of an air bubble that was injected through a three-way stopcock was measured in the arterial pressure line between the pigtail catheter and ECMO inflow limb. The flow rate was then calculated. We obtained the following equation to estimate the pigtail catheter flow rate.Pigtail vent catheter flow rate (ml/min) = 8×ECMOflow rate(L /min)+9×pigtail catheter size(Fr)- 57This equation would aid in designing of a further study to determine optimal venting flow rate. To achieve optimal venting flow, our equation would enable selection of an adequate catheter size.
Complications of Peripherally Inserted Central Venous Catheters: A Retrospective Cohort Study
Jose Amo-Setién, Francisco; Herrero-Montes, Manuel; Olavarría-Beivíde, Encarnación; Rodríguez-Rodríguez, Mercedes; Torres-Manrique, Blanca; Rodríguez-de la Vega, Carlos; Caso-Álvarez, Vanesa; González-Parralo, Laura
2016-01-01
Background and Aim The use of venous catheters is a widespread practice, especially in oncological and oncohematological units. The objective of this study was to evaluate the complications associated with peripherally inserted central catheters (PICCs) in a cohort of patients. Materials and Methods In this retrospective cohort study, we included all patient carrying PICCs (n = 603) inserted at our institute between October 2010 and December 2013. The main variables collected were medical diagnosis, catheter care, location, duration of catheterization, reasons for catheter removal, complications, and nursing care. Complications were classified as infection, thrombosis, phlebitis, migration, edema, and/or ecchymosis. Results All patients were treated according to the same “nursing care” protocol. The incidence rate of complications was two cases per 1000 days of catheter duration. The most relevant complications were infection and thrombosis, both with an incidence of 0.17 cases per 1000 days of the total catheterization period. The total average duration of catheterization was 170 days [SD 6.06]. Additionally to “end of treatment” (48.42%) and “exitus”, (22.53%) the most frequent cause of removal was migration (displacement towards the exterior) of the catheter (5.80%). Conclusions PICCs are safe devices that allow the administration of long-term treatment and preserve the integrity of the venous system of the patient. Proper care of the catheter is very important to improve the quality life of patients with oncologic and hematologic conditions. Therefore, correct training of professionals and patients as well as following the latest scientific recommendations are particularly relevant. PMID:27588946
Neonatal atrial flutter after insertion of an intracardiac umbilical venous catheter
de Almeida, Marcos Moura; Tavares, Wládia Gislaynne de Sousa; Furtado, Maria Mônica Alencar Araripe; Fontenele, Maria Marcia Farias Trajano
2016-01-01
Abstract Objective: To describe a case of neonatal atrial flutter after the insertion of an intracardiac umbilical venous catheter, reporting the clinical presentation and reviewing the literature on this subject. Case description: A late-preterm newborn, born at 35 weeks of gestational age to a diabetic mother and large for gestational age, with respiratory distress and rule-out sepsis, required an umbilical venous access. After the insertion of the umbilical venous catheter, the patient presented with tachycardia. Chest radiography showed that the catheter was placed in the position that corresponds to the left atrium, and traction was applied. The patient persisted with tachycardia, and an electrocardiogram showed atrial flutter. As the patient was hemodynamically unstable, electric cardioversion was successfully applied. Comments: The association between atrial arrhythmias and misplaced umbilical catheters has been described in the literature, but in this case, it is noteworthy that the patient was an infant born to a diabetic mother, which consists in another risk factor for heart arrhythmias. Isolated atrial flutter is a rare tachyarrhythmia in the neonatal period and its identification is essential to establish early treatment and prevent systemic complications and even death. PMID:26525686
Safe percutaneous suprapubic catheterisation
Goyal, NK; Goel, A; Sankhwar, SN
2012-01-01
INTRODUCTION We describe our technique of percutaneous suprapubic catheter insertion with special reference to steps that help to avoid common complications of haematuria and catheter misplacement. METHODS The procedure is performed using a stainless steel reusable trocar under local infiltrative anaesthesia, usually at the bedside. After clinical confirmation of a full bladder, the trocar is advanced into the bladder through a skin incision. Once the bladder is entered, the obturator is removed and the assistant inserts a Foley catheter followed by rapid balloon inflation. Slight traction is applied to the catheter for about five minutes. Patients with previous lower abdominal surgery, an inadequately distended bladder or acute pelvic trauma do not undergo suprapubic catheterisation using this method. RESULTS The procedure was performed in 72 men (mean age: 42.4 years, range: 18–78 years) with urinary retention with a palpable bladder. The average duration of the procedure was less than five minutes. No complications were noted in any of the patients. CONCLUSIONS Trocar suprapubic catheter insertion is a safe and effective bedside procedure for emergency bladder drainage and can be performed by resident surgeons. The common complications associated with the procedure can be avoided with a few careful steps. PMID:23131233
Clemence, Bonnie J; Maneval, Rhonda E
2014-01-01
This is part 1 of a 2-part series of articles that report on the results of a prospective observational cohort study designed to examine the risk factors associated with symptomatic upper extremity deep vein thrombosis (UEDVT) in patients with peripherally inserted central catheters. This article provides an extensive review and critique of the literature that serves to explicate what is currently known about risk factors associated with catheter-related UEDVT. Risk factors such as anticoagulant use, cancer, infection, hypertension, catheter tip placement, and catheter size were identified most frequently in the literature as being associated with UEDVT development. Other risk factors--such as obesity, smoking history, surgery, and presence of pain or edema--were examined in a limited number of studies and lacked consistent evidence of their impact on UEDVT development. The subsequent study that evolved from the review of the literature investigates the relationship between identified risk factors and UEDVT development.
Gen, Shikou; Inoue, Tsutomu; Nodaira, Yuka; Ikeda, Naofumi; Kobayashi, Kazuhiro; Watanabe, Yusuke; Kanno, Yoshihiko; Nakamoto, Hidetomo; Suzuki, Hiromichi
2008-01-01
In the present study, we examined the association between vascular and valvular calcification and the prognosis of patients on continuous ambulatory peritoneal dialysis (CAPD). Data were collected from the records of patients introduced onto CAPD therapy during 1999 - 2006 at the Department of Nephrology, Saitama Medical University. At the start of CAPD, cardiac and vascular echography were used to examine 162 patients (average age: 56 +/- 5 years; 58 men, 104 women; 43 with and 119 without diabetes) for evaluation of vascular and valvular calcification. Both vascular and valvular calcification were found in 32 patients. Vascular calcification was found in 16, and valvular calcification in 11. Over 5 years, 11 patients suffered from cardiovascular disease (7 with stroke, 4 with myocardial infarction). All of these patients had vascular or valvular calcification at the start of CAPD therapy. We also used Cox hazard analysis to examine values for Ca, P, Ca x P, intact parathyroid hormone (iPTH), and lipids. None of these values were independent contributory factors for incidence of cardiovascular disease in patients on CAPD. These data suggest the importance of vascular and valvular echography to evaluate patients on CAPD, especially at the start of CAPD therapy. Vascular and valvular calcification are important factors for determining the prognosis of patients on CAPD.
Kampf, Günter; Reise, Gesche; James, Claudia; Gittelbauer, Kirsten; Gosch, Jutta; Alpers, Birgit
2013-01-01
Peripheral venous catheters are frequently used in hospitalized patients but increase the risk of nosocomial bloodstream infection. Evidence-based guidelines describe specific steps that are known to reduce infection risk. However, the degree of guideline implementation in clinical practice is not known. The aim of this study was to determine the use of specific steps for insertion of peripheral venous catheters in clinical practice and to implement a multimodal intervention aimed at improving both compliance and the optimum order of the steps. The study was conducted at University Hospital Hamburg. An optimum procedure for inserting a peripheral venous catheter was defined based on three evidence-based guidelines (WHO, CDC, RKI) including five steps with 1A or 1B level of evidence: hand disinfection before patient contact, skin antisepsis of the puncture site, no palpation of treated puncture site, hand disinfection before aseptic procedure, and sterile dressing on the puncture site. A research nurse observed and recorded procedures for peripheral venous catheter insertion for healthcare workers in four different departments (endoscopy, central emergency admissions, pediatrics, and dermatology). A multimodal intervention with 5 elements was established (teaching session, dummy training, e-learning tool, tablet and poster, and direct feedback), followed by a second observation period. During the last observation week, participants evaluated the intervention. In the control period, 207 insertions were observed, and 202 in the intervention period. Compliance improved significantly for four of five steps (e.g., from 11.6% to 57.9% for hand disinfection before patient contact; p<0.001, chi-square test). Compliance with skin antisepsis of the puncture site was high before and after intervention (99.5% before and 99.0% after). Performance of specific steps in the correct order also improved (e.g., from 7.7% to 68.6% when three of five steps were done; p<0.001). The intervention was described as helpful by 46.8% of the participants, as neutral by 46.8%, and as disruptive by 6.4%. A multimodal strategy to improve both compliance with safety steps for peripheral venous catheter insertion and performance of an optimum procedure was effective and was regarded helpful by healthcare workers.
Noritomi, Danilo Teixeira; Zigaib, Rogério; Ranzani, Otavio T; Teich, Vanessa
2016-01-01
To evaluate the cost-effectiveness, from the funding body's point of view, of real-time ultrasound-guided central venous catheter insertion compared to the traditional method, which is based on the external anatomical landmark technique. A theoretical simulation based on international literature data was applied to the Brazilian context, i.e., the Unified Health System (Sistema Único de Saúde - SUS). A decision tree was constructed that showed the two central venous catheter insertion techniques: real-time ultrasonography versus external anatomical landmarks. The probabilities of failure and complications were extracted from a search on the PubMed and Embase databases, and values associated with the procedure and with complications were taken from market research and the Department of Information Technology of the Unified Health System (DATASUS). Each central venous catheter insertion alternative had a cost that could be calculated by following each of the possible paths on the decision tree. The incremental cost-effectiveness ratio was calculated by dividing the mean incremental cost of real-time ultrasound compared to the external anatomical landmark technique by the mean incremental benefit, in terms of avoided complications. When considering the incorporation of real-time ultrasound and the concomitant lower cost due to the reduced number of complications, the decision tree revealed a final mean cost for the external anatomical landmark technique of 262.27 Brazilian reals (R$) and for real-time ultrasound of R$187.94. The final incremental cost of the real-time ultrasound-guided technique was -R$74.33 per central venous catheter. The incremental cost-effectiveness ratio was -R$2,494.34 due to the pneumothorax avoided. Real-time ultrasound-guided central venous catheter insertion was associated with decreased failure and complication rates and hypothetically reduced costs from the view of the funding body, which in this case was the SUS.
Blind urethral catheterization in trauma patients suffering from lower urinary tract injuries.
Shlamovitz, Gil Z; McCullough, Lynne
2007-02-01
The goals of our study were to review all cases of urethral and bladder trauma that presented to the University of California, Los Angeles (UCLA) Medical Center between January 1998 and August 2005 and determine (1) the clinical characteristics of patients with urethral and/or bladder injuries as well as the sensitivities of those clinical characteristics; (2) whether or not a blind attempt to insert a urethral catheter was performed; and (3) whether there is any evidence that a blind attempt to insert a urethral catheter worsened the initial urinary tract injury. This is a retrospective chart review. The study cohort comprised 46 patients with a mean age of 30 years, including 36 men (78.2%) and 10 women (21.8%). Bladder tears were found in 33 patients, 10 patients had urethral lacerations, and 3 patients had combined bladder and urethral lacerations. The most sensitive finding for urinary bladder or urethral injury was the presence of gross hematuria in the urethral catheter (100%, 95% confidence interval [CI] 0.63-0.89). Blinded insertion of a urethral catheter was attempted in 30 (90.9%, 95% CI 0.75-0.98) patients who suffered from urinary bladder injury, 6 (50%, 95% CI 0.26-0.87) patients who suffered from urethral injury and 1 (33%, 95% CI 0.0-0.9) patient who suffered from a combined urinary bladder and urethral injuries. We did not find evidence that a blind attempt to insert a urethral catheter worsened the initial urinary injury. Gross hematuria in the urethral catheter was the most sensitive sign for the presence of a urethral or urinary bladder injury in our study cohort, and often the only sign of such an injury. We found no evidence that a blind attempt to insert a urethral catheter in patients suffering from urethral and or urinary bladder injuries worsened the initial injury. Larger studies will be needed to determine the safety of blind urethral catheterization in patients that are suspected to suffer from a lower urological trauma. It is our opinion that the current guidelines should be revised to better reflect the current knowledge, technologies, and clinical practice.
AAA (2010) CAPD clinical practice guidelines: need for an update.
DeBonis, David A
2017-09-01
Review and critique of the clinical value of the AAA CAPD guidance document in light of criteria for credible and useful guidance documents, as discussed by Field and Lohr. A qualitative review of the of the AAA CAPD guidelines using a framework by Field and Lohr to assess their relative value in supporting the assessment and management of CAPD referrals. Relevant literature available through electronic search tools and published texts were used along with the AAA CAPD guidance document and the chapter by Field and Lohr. The AAA document does not meet many of the key requirements discussed by Field and Lohr. It does not reflect the current literature, fails to help clinicians understand for whom auditory processing testing and intervention would be most useful, includes contradictory suggestions which reduce clarity and appears to avoid conclusions that might cast the CAPD construct in a negative light. It also does not include input from diverse affected groups. All of these reduce the document's credibility. The AAA CAPD guidance document will need to be updated and re-conceptualised in order to provide meaningful guidance for clinicians.
Catheter-related bloodstream infection.
Goede, Matthew R; Coopersmith, Craig M
2009-04-01
Catheter-related bloodstream infections (CR-BSIs) are a common, frequently preventable complication of central venous catheterization. CR-BSIs can be prevented by strict attention to insertion and maintenance of central venous catheters and removing unneeded catheters as soon as possible. Antiseptic- or antibiotic-impregnated catheters are also an effective tool to prevent infections. The diagnosis of CR-BSI is made largely based on culture results. CR-BSIs should always be treated with antibiotics, and except in rare circumstances the infected catheter needs to be removed.
Dettenkofer, M; Wilson, C; Gratwohl, A; Schmoor, C; Bertz, H; Frei, R; Heim, D; Luft, D; Schulz, S; Widmer, A F
2010-06-01
To compare the efficacy of two commercially available, alcohol-based antiseptic solutions for preparation and care of central venous catheter (CVC) insertion sites, with and without octenidine dihydrochloride, a double-blind, randomized, controlled trial was undertaken in the haematology units and in one surgical unit of two university hospitals. Adult patients with a non-tunnelled CVC were randomly assigned to two different skin disinfection regimens at the insertion site: 0.1% octenidine with 30% 1-propanol and 45% 2-propanol, and as control 74% ethanol with 10% 2-propanol. Endpoints were (i) skin colonization at the insertion site; (ii) positive culture from the catheter tip (> or = 15 CFU); and (iii) occurrence of CVC-associated bloodstream infection (defined according to criteria set by the CDC). Four hundred patients with inserted CVC were enrolled from May 2002 through April 2005. Both groups were similar in respect of patient characteristics and co-morbidities. Skin colonization at the CVC insertion site during the first 10 days was significantly reduced by octenidine treatment (relative difference octenidine vs. control: 0.21; 95%CI: 0.11-0.39, p <0.0001). Positive culture of the catheter tip was significantly less frequent in the octenidine group (7.9%) than in the control group (17.8%): OR = 0.39 (95%CI: 0.20-0.80, p 0.009). Patients treated with octenidine had a non-significant reduction in catheter-associated bloodstream infections (4.1% vs. 8.3%; OR = 0.44; 95%CI: 0.18-1.08, p 0.081). Side effects were similar in both groups. This randomized controlled trial supports the results of two observational studies demonstrating octenidine in alcoholic solution to be a better option than alcohol alone for the prevention of CVC-associated infections.
Viana Taveira, Michelle Ribeiro; Lima, Luciana Santana; de Araújo, Cláudia Corrêa; de Mello, Maria Júlia Gonçalves
2017-02-01
Totally implantable venous access ports (TIVAPs) are used for prolonged central venous access, allowing the infusion of chemotherapy and other fluids and improving the quality of life of children with cancer. TIVAPs were developed to reduce the infection rates associated with central venous catheters; however, infectious events remain common and have not been fully investigated in pediatric oncology patients. A retrospective cohort was formed to investigate risk factors for central line-associated bloodstream infection (CLABSI) in pediatric cancer patients. Sociodemographic, clinical, and TIVAP insertion-related variables were evaluated, with the endpoint being the first CLABSI. A Kaplan-Meier analysis was performed to determine CLABSI-free catheter survival. Overall, 188 children were evaluated over 77,541 catheter days, with 94 being diagnosed with CLABSI (50%). Although coagulase-negative staphylococci were the pathogens most commonly isolated, Gram-negative microorganisms (46.8%) were also prevalent. In the multivariate analysis, factors that increased the risk for CLABSI were TIVAP insertion prior to chemotherapy (risk ratio [RR] = 1.56; P < 0.01), white blood cell count less than 1,000 mm -3 on the day of implantation (RR = 1.64; P < 0.01), and chronic malnutrition (RR = 1.41; P < 0.05). Median time without CLABSI following TIVAP insertion was 74.5 days. Risk factors for CLABSI in pediatric cancer patients with a TIVAP may be related to the severity of the child's condition at catheter insertion. Insertion of the catheter before chemotherapy and unfavorable conditions such as malnutrition and bone marrow aplasia can increase the risk of CLABSI. Protocols must be revised and surveillance increased over the first 10 weeks of treatment. © 2016 Wiley Periodicals, Inc.
21 CFR 880.5200 - Intravascular catheter.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Devices § 880.5200 Intravascular catheter. (a) Identification. An intravascular catheter is a device that consists of a slender tube and any necessary connecting fittings and that is inserted into the patient's vascular system for short term use (less than 30 days) to sample blood, monitor blood pressure, or...
Solinas, Gianfranca; Platini, Francesca; Trivellato, Maurizio; Rigo, Carla; Alabiso, Oscar; Galetto, Alessandra S
2017-07-14
Patients with cancer need stable venous access using central vascular devices like central venous ports and peripherally inserted central catheters that can be used for a wide range of indications. Numerous flushing protocols exist including different frequencies for catheter locking to maintain catheter patency. The aim of this retrospective study was to evaluate the incidence of lumen occlusion of central venous ports in a group of adult cancer patients, adopting a policy of locking with normal saline every three months. This is a single-center retrospective observational study. During follow-up, we analyzed adult cancer patients who had undergone port insertion from January 1st, 2007 to August 31st, 2014. Flushing and locking were performed every three months with a syringe containing normal saline. We collected data from 381 patients with ports inserted in subclavian vein (379 patients) and in the right jugular vein (2 patients). Locking was performed during 3-monthly follow-up visits. Median follow-up was 810 days (90-2700 days). Among 381 ports, 59 were removed; the reasons for removal were: end of use (45 cases), catheter rupture (9 cases), dislocation (3 cases) and catheter-related bloodstream infection (2 cases). We had no reports of lumen occlusion. Our data suggest that locking ports with normal saline every three months is not associated with an increased risk of lumen occlusion.
Central Venous Catheter Insertion Site and Colonization in Pediatric Cardiac Surgery
2017-11-04
Central Line-associated Bloodstream Infection (CLABSI); Central Venous Catheter Associated Bloodstream Infection; Heart; Surgery, Heart, Functional Disturbance as Result; Congenital Heart Disease; Newborn; Infection
Fink, Regina; Gilmartin, Heather; Richard, Angela; Capezuti, Elizabeth; Boltz, Marie; Wald, Heidi
2012-10-01
Indwelling urinary catheters (IUCs) are commonly used in hospitalized patients, especially elders. Catheter-associated urinary tract infections (CAUTIs) account for 34% of all health care associated infections in the United States, associated with excess morbidity and health care costs. Adherence to CAUTI prevention practices has not been well described. This study used an electronic survey to examine IUC care practices for CAUTI prevention in 3 areas-(1) equipment and alternatives and insertion and maintenance techniques; (2) personnel, policies, training, and education; and (3) documentation, surveillance, and removal reminders-at 75 acute care hospitals in the Nurses Improving the Care of Healthsystem Elders (NICHE) system. CAUTI prevention practices commonly followed included wearing gloves (97%), handwashing (89%), maintaining a sterile barrier (81%), and using a no-touch insertion technique (73%). Silver-coated catheters were used to varying degrees in 59% of the hospitals; 4% reported never using a catheter-securing device. Urethral meatal care was provided daily by 43% of hospitals and more frequently that that by 41% of hospitals. Nurses were the most frequently reported IUC inserters. Training in aseptic technique and CAUTI prevention at the time of initial nursing hire was provided by 64% of hospitals; however, only 47% annually validated competency in IUC insertion. Systems for IUC removal were implemented in 56% of hospitals. IUC documentation and routine CAUTI surveillance practices varied widely. Although many CAUTI prevention practices at NICHE hospitals are in alignment with evidence-based guidelines, there is room for improvement. Further research is needed to identify the effect of enhanced compliance with CAUTI prevention practices on the prevalence of CAUTI in NICHE hospitals. Copyright © 2012 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
Brenneman, Lauren; Cash, Elizabeth; Chermak, Gail D; Guenette, Linda; Masters, Gay; Musiek, Frank E; Brown, Mallory; Ceruti, Julianne; Fitzegerald, Krista; Geissler, Kristin; Gonzalez, Jennifer; Weihing, Jeffrey
2017-09-01
Pediatric central auditory processing disorder (CAPD) is frequently comorbid with other childhood disorders. However, few studies have examined the relationship between commonly used CAPD, language, and cognition tests within the same sample. The present study examined the relationship between diagnostic CAPD tests and "gold standard" measures of language and cognitive ability, the Clinical Evaluation of Language Fundamentals (CELF) and the Wechsler Intelligence Scale for Children (WISC). A retrospective study. Twenty-seven patients referred for CAPD testing who scored average or better on the CELF and low average or better on the WISC were initially included. Seven children who scored below the CELF and/or WISC inclusion criteria were then added to the dataset for a second analysis, yielding a sample size of 34. Participants were administered a CAPD battery that included at least the following three CAPD tests: Frequency Patterns (FP), Dichotic Digits (DD), and Competing Sentences (CS). In addition, they were administered the CELF and WISC. Relationships between scores on CAPD, language (CELF), and cognition (WISC) tests were examined using correlation analysis. DD and FP showed significant correlations with Full Scale Intelligence Quotient, and the DD left ear and the DD interaural difference measures both showed significant correlations with working memory. However, ∼80% or more of the variance in these CAPD tests was unexplained by language and cognition measures. Language and cognition measures were more strongly correlated with each other than were the CAPD tests with any CELF or WISC scale. Additional correlations with the CAPD tests were revealed when patients who scored in the mild-moderate deficit range on the CELF and/or in the borderline low intellectual functioning range on the WISC were included in the analysis. While both the DD and FP tests showed significant correlations with one or more cognition measures, the majority of the variance in these CAPD measures went unexplained by cognition. Unlike DD and FP, the CS test was not correlated with cognition. Additionally, language measures were not significantly correlated with any of the CAPD tests. Our findings emphasize that the outcomes and interpretation of results vary as a function of the subject inclusion criteria that are applied for the CELF and WISC. Including participants with poorer cognition and/or language scores increased the number of significant correlations observed. For this reason, it is important that studies investigating the relationship between CAPD and other domains or disorders report the specific inclusion criteria used for all tests. American Academy of Audiology
Tang, Chao-Hsiun; Wu, Yu-Ting; Huang, Siao-Yuan; Chen, Hsi-Hsien; Wu, Ming-Ju; Hsu, Bang-Gee; Tsai, Jer-Chia; Chen, Tso-Hsiao; Sue, Yuh-Mou
2017-03-21
Taiwan succeeded in raising the proportion of peritoneal dialysis (PD) usage after the National Health Insurance (NHI) payment scheme introduced financial incentives in 2005. This study aims to compare the economic costs between automated PD (APD) and continuous ambulatory PD (CAPD) modalities from a societal perspective. A retrospective cohort of patients receiving PD from the NHI Research Database was identified during 2004-2011. The 1:1 propensity score matched 1749 APD patients and 1749 CAPD patients who were analysed on their NHI-financed medical costs and utilisation. A multicentre study by face-to-face interviews on 117 APD and 129 CAPD patients from five hospitals located in four regions of Taiwan was further carried out to collect data on their out-of-pocket payments, productivity losses and quality of life with EuroQol-5D-5L. The NHI-financed medical costs, out-of-pocket payments and productivity losses of APD and CAPD patients. The total NHI-financed medical costs per patient-year after 5 years of follow-up were significantly higher with APD than CAPD (US$23 005 vs US$19 237; p<0.01). In terms of dialysis-related costs, APD had higher costs resulting from the use of APD machines (US$795) and APD sets (US$2913). Significantly lower productivity losses were found with APD (US$2619) than CAPD (US$6443), but the out-of-pocket payments were not significantly different. The differences in NHI-financed medical costs and productivity losses between APD and CAPD remained robust in the bootstrap analysis. The total economic costs of APD (US$30 401) were similar to those of CAPD (US$29 939), even after bootstrap analysis (APD, US$28 399; CAPD, US$27 960). No discernable differences were found in the results of mortality and quality of life between the APD and CAPD patients. APD had higher annual dialysis-related costs and lower annual productivity losses than CAPD, which made the economic costs of APD very close to those of CAPD in Taiwan. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Valencia, Cesar A Restrepo; Villa, Carlos A Buitrago; Cardona, Jose A Chacon
2013-01-01
Background We compared the results of four different methods of hemodialysis catheter insertion in the medial segment of the axillary vein: ultrasound guidance, palpation, anatomical reference, and prior transient catheter. Methods All patients that required acute or chronic hemodialysis and for whom it was determined impossible or not recommended either to place a catheter in the internal jugular vein (for instance, those patients with a tracheostomy), or to practice arteriovenous fistula or graft; it was then essential to obtain an alternative vascular access. When the procedure of axillary vein catheter insertion was performed in the Renal Care Facility (RCF), ultrasound guidance was used, but in the intensive care unit (ICU), this resource was unavailable, so the palpation or anatomical reference technique was used. Results Two nephrologists with experience in the technique performed 83 procedures during a period lasting 15 years and 8 months (from January 1997–August 2012): 41 by ultrasound guidance; 19 by anatomical references; 15 by palpation of the contiguous axillary artery; and 8 through a temporary axillary catheter previously placed. The ultrasound-guided patients had fewer punctures than other groups, but the value was not statistically significant. Arterial punctures were infrequent in all techniques. Analyzing all the procedure-related complications, such as hematoma, pneumothorax, brachial-plexus injury, as well as the reasons for catheter removal, no differences were observed among the groups. The functioning time was longer in the ultrasound-guided and previous catheter groups. In 15 years and 8 months of surveillance, no clinical or image evidence for axillary vein stenosis was found. Conclusion The ultrasound guide makes the procedure of inserting catheters in the axillary veins easier, but knowledge of the anatomy of the midaxillary region and the ability to feel the axillary artery pulse (for the palpation method) also allow relatively easy successful implant of catheters in the axillary veins. PMID:24143120
Ahlin, C; Klang-Söderkvist, B; Johansson, E; Björkholm, M; Löfmark, A
2017-03-01
Venepuncture and the insertion of peripheral venous catheters are common tasks in health care, and training in these procedures is included in nursing programmes. Evidence of nursing students' knowledge and skills in these procedures is limited. The main aim of this study was to assess nursing students' knowledge and skills when performing venepuncture and inserting peripheral venous catheters. Potential associations between level of knowledge and skills, self-training, self-efficacy, and demographic characteristics were also investigated. The assessment was performed by lecturers at a university college in Sweden using the two previously tested instruments "Assess Venepuncture" and "Assess Peripheral Venous Catheter Insertion". Between 81% and 100% of steps were carried out correctly by the students. The step with the highest rating was "Uses gloves", and lowest rating was 'Informs the patients about the possibility of obtaining local anaesthesia'. Significant correlations between degree of self-training and correct performance were found in the group of students who registered their self-training. No associations between demographic characteristics and correct performances were found. Assessing that students have achieved adequate levels of knowledge and skills in these procedures at different levels of the nursing education is of importance to prevent complications and support patient safety. Copyright © 2017 Elsevier Ltd. All rights reserved.
[NEOCAT, surveillance network of catheter-related bloodstream infections in neonates: 2010 data].
L'Hériteau, F; Lacavé, L; Leboucher, B; Decousser, J-W; De Chillaz, C; Astagneau, P; Aujard, Y
2012-09-01
The NEOCAT surveillance network was implemented in 2006 in order to address catheter-associated bloodstream infections (BSIs) in neonates. The results for 2010 surveillance are presented herein. Neonatal intensive care units (NICUs) participated in the study on a voluntary basis. Umbilical catheters (UCs) and central venous catheters (CVCs) were analyzed separately. In 2010, 26NICUs participated. Overall, 2953 neonates were included (median weight, 1550 g; median gestational age, 32 weeks). These neonates had 2551UCs (median insertion duration, 4 days) and 2147CVCs (median insertion duration, 12 days). Thirty-three BSIs associated with UCs were reported, yielding a 2.9/1000UC-day incidence density, 95% confidence interval (95%CI) (1.9-3.8). UC-associated BSIs appeared after a median period of 5 days after UC insertion. The main microorganism isolated from blood cultures was coagulase negative staphylococci (CNS, n=27), S. aureus (n=3), and Enterobacteriaceae (n=5). Three hundred and six CVC-associated BSIs were recorded, yielding a 11.2/1000 CVC-day incidence density (95%CI, 10.0-12.5). These BSIs occurred after a median period of 12 days after CVC insertion. The main microorganisms were CNS (83%), S. aureus (6%), and Enterobacteriaceae (5%). The NEOCAT network provides a useful benchmark for participating wards. Copyright © 2012 Elsevier Masson SAS. All rights reserved.
Wood, Paul; Gill, M; Edwards, D; Clifton, P; Bullock, C; Aldington, D
2016-08-01
The adoption of regional and epidural analgesia in UK military personnel injured in action during Op HERRICK increased from 2008, in line with structural and environmental developments in the UK medical treatment facility. Historically, there have been concerns that invasive analgesic techniques could carry an increased risk of infection, due to the mechanism of injury and the environmental conditions in which the injuries were sustained. Consequently, the epidural and continuous peripheral nerve blockade (CPNB) catheters that were inserted in UK military personnel during a 33-month period of Op HERRICK were clinically and microbiologically examined, after subsequent admission to the University Hospitals Birmingham (UHB) NHS Trust. Data on epidural and CPNB insertions were collected via the specialist pain service at UHB over the study period, including de novo and replacement insertions performed in both Afghanistan and the UK. Patients were regularly reviewed and relevant clinical concerns were documented in patients' case notes as necessary. The anatomical site, duration of placement and the results of microbiological culture of the epidural and CPNB catheter tips were all recorded. Overall, 236 catheters were assessed, of which 151 catheter tips (64%) were cultured (85 epidural, 66 CPNB). Of these, 48 grew bacteria (34% of cultured epidurals and 29% of cultured CPNB). There was no difference between the colonisation rates of epidurals inserted in Afghanistan and the UK. Only one infection related to a misplaced epidural catheter was confirmed. With the exception of the epidural (34%) and proximal sciatic (42%) catheters, these figures, in a military cohort characterised by significant injury scores, are consistent with those reported for civilian surgical patients. The results strongly support the expansion of regional analgesia during Op HERRICK from 2008 onwards. The outcomes suggest a possible translation into civilian major trauma practice. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Exit-site infections by non-diphtheria corynebacteria in CAPD.
Schiffl, Helmut; Mücke, Claudia; Lang, Susanne M
2004-01-01
Non-diphtheria corynebacteria species cause disease in risk populations such as immunocompromised patients and patients with indwelling medical devices. Despite reports of exit-site infection and peritonitis caused by non-diphtheria corynebacteria, these organisms are frequently dismissed as contaminants. During a 10-year observation period, we prospectively identified 8 cases of exit-site/tunnel infections caused by 2 different species of corynebacteria (Corynebacterium striatum in 5 and C. jeikeium in 3 cases). Four patients experienced a second episode of exit-site infection 3 months (2 cases), 25 months, and 40 months, respectively, after termination of an oral cephalosporin therapy of 4 to 6 weeks' duration. Non-diphtheria corynebacteria accounted for 9% of all exit-site infections during the study period. All catheter-related infections healed; no catheter had to be removed. The diagnosis of catheter-related non-diphtheria corynebacteria infection may be suspected when Gram stain shows gram-positive rods and with colony morphology and commercial biochemical identification systems. Susceptibility of non-diphtheria corynebacteria to antibiotics may vary, especially in C. jeikeium. Virtually all Corynebacterium species are sensitive to vancomycin. Empirical antibiotic therapy with vancomycin should be initiated while antibiotic susceptibility testing is being carried out. Oral cephalosporin may be an alternative treatment regimen for exit-site infections if sensitive. This study highlights the importance of non-diphtheria corynebacteria as emerging nosocomial pathogens in the population of end-stage renal disease patients on on continuous ambulatory peritoneal dialysis.
Knowledge of nursing students about central venous catheters.
Mlinar, Suzana; Malnarsić, Rosanda Rasković
2012-04-01
Central venous catheters (CVC) are at the crucial importance, particulary in the intensive therapy units. In order to handle a CVC safely, nursing students need to acquire theoretical and practical knowledge during the course of their studies. The aim of the study was to establish theoretical knowledge of nursing students about the procedures of nurses in placing and removing a central venous catheter (CVC), dressing the catheter entry point, the reasons for measuring central venous pressure (CVP), possible complications and risk factors for developing infections related to CVC. The questionnaire developed specifically for this cross-sectionl study was handed out to 87 full-time students and 57 part-time students. The results show that all the surveyed nursing students know why chest radiography is carried out when inserting a catheter, have relatively good knowledge of CVC insertion points, procedures carried out in case of a suspected catheter sepsis and complications and risk factors for the development of infections related to CVC. However, the study show that the majority of students have insufficient knowledge of the procedures accompanying insertion of a catheter, signs that indicate correct functioning of CVC, frequency of flushing a catheter when it is not in use and the reasons for introducing an implanted CVC. Based on the results of the study it can be concluded that the second-year nursing students have insufficient knowledge of CVC. In order to correctly and safely handle a CVC, good theoretical knowledge and relevant practical experience are needed. The authors therefore believe that, in future, the classes should be organized in smaller groups with step-by-step demonstrations of individual procedures in handling a CVC, and the students encouraged to learn as actively as possible.
... insert your catheter: Wash your hands well with soap and water. Collect your supplies, including your catheter ( ... penis with Betadine (an antiseptic cleaner), a towelette, soap and water, or baby wipes the way your ...
Abdullah, B J J; Mohammad, N; Sangkar, J V; Abd Aziz, Y F; Gan, G G; Goh, K Y; Benedict, I
2005-07-01
The objective of this study was to prospectively determine the incidence of venous thrombosis (VT) in the upper limbs in patients with peripherally inserted central catheters (PICC). We prospectively investigated the incidence of VT in the upper limbs of 26 patients who had PICC inserted. The inclusion criteria were all patients who had a PICC inserted, whilst the exclusion criterion was the inability to perform a venogram (allergies, previous contrast medium reaction and inability of gaining venous access). Both valved and non-valved catheters were evaluated. Prior to removal of the PICC, an upper limb venogram was performed. The number of segments involved with VT were determined. The duration of central venous catheterization was classified as; less than 6 days, between 6 days and 14 days and more than 14 days. VT was confirmed in 38.5% (10/26) of the patients. The majority 85.7% (12/14) were complete occlusive thrombi and the majority of VT only involved one segment. There was no statistical correlation between the site of insertion of the PICC and the location of VT. Neither was there any observed correlation between the occurrence of VT with the patient's history of hypertension, hypercholesterolaemia, coronary artery disease, diabetes mellitus, cardiac insufficiency, smoking or cancer. There was also no statistical correlation with the size of the catheter. In conclusion, PICCs are associated with a significant risk of upper extremity deep vein thrombosis (UEVT).
... Catheterization • Urinary Tract Infections: Indwelling (Foley) Catheter Bladder Management [ Download this pamphlet: "Bladder Management" - (PDF, 499KB) ] The ... and medication or surgery may be helpful. Bladder Management Foley or Suprapubic Catheter A tube is inserted ...
Comparcini, Dania; Simonetti, Valentina; Blot, Stijn; Tomietto, Marco; Cicolini, Giancarlo
2017-01-01
To explore the relationship between the anatomical site of peripheral venous catheterization and risk of catheter-related phlebitis. Peripheral venous catheterization is frequently associated with phlebitis. Recent guidelines, recommend the use of an upper-extremity site for catheter insertion but no univocal consensus exists on the anatomical site with lower risk of phlebitis. Systematic review. We searched Medline (PubMed) and CINAHL (EBSCOhost) databases until the end of January 2017. We also reviewed the reference lists of retrieved articles and gray literature was excluded. Searches were limited to articles published in English with no restriction imposed to date of publication. The primary outcome was the incidence of phlebitis associated with anatomical site of peripheral catheterization. We included randomized controlled trials and observational studies on adult patients who required a peripheral catheter for the administration of medi- cation, intermittent or continuous fluid infusion. Antecubital fossa veins are associated with lower phlebitis rates, while hands veins are the most risky sites to develop phlebitis. There is no consensus regarding vein in forearm. Choosing the right anatomical site to insert a peripheral venous catheter is important to decrease phlebitis rate. Further studies should compare indwelling time in different anatomical sites with phlebitis rate. A more standardized approach in defining and assessing phlebitis among studies is recommended.
Cystoscopic temporary ureteral catheterization during radical vaginal and abdominal trachelectomy.
Abu-Rustum, Nadeem R; Sonoda, Yukio; Black, Destin; Chi, Dennis S; Barakat, Richard R
2006-11-01
To describe the role of temporary retrograde ureteral catheterization at the time of fertility-sparing radical vaginal or abdominal trachelectomy in women with early-stage cervical cancer. We analyzed a prospectively maintained database of all patients with cervical cancer who were explored for radical vaginal or abdominal trachelectomy at our institution. Cystourethroscopy and ureteral catheterization were performed prior to the vaginal or abdominal operation in all patients, except two pediatric ones. Temporary bilateral retrograde ureteral catheters were planned for all patients as part of our routine procedure to facilitate identification of the distal ureters. 5Fr whistle-tip or open-ended catheters were used and usually advanced to approximately 20 cm. Catheters were removed at the end of the operation in all cases. All catheters were inserted by a gynecologic oncology fellow or attending. Between 11/01 and 12/05, 40 patients were taken to the operating room for planned fertility-sparing radical vaginal or abdominal trachelectomy. We previously reported on two pediatric patients; they are excluded from this report. The median age for adult patients was 32 years (mean, 31.6; range, 23-40). International Federation of Gynecology and Obstetrics (FIGO) stage included IB1 (26), IA2 (6), and IA1 with lymphovascular invasion (6). Thirty-four patients underwent radical vaginal trachelectomy and four underwent a radical abdominal trachelectomy. Two (5%) of 38 patients required immediate completion radical hysterectomy due to extensive endocervical disease (one in the vaginal group and one in the abdominal group). Bilateral ureteral catheters were inserted successfully in 37 (97%) of 38 patients and facilitated identification of the distal ureter during the dissection. In one case, the right ureteral orifice could not be successfully catheterized, and the case was completed with unilateral catheterization. The estimated time to perform this part of the operation was approximately 15-20 min. Twenty-eight patients (74%) had 5Fr whistle-tip ureteral catheters inserted, and 10 had open-ended catheters inserted. There were no intraoperative complications. Median hospital stay was 3 days (range, 3-7). Hematuria, evident in the drainage bag attached to the Foley catheter, usually resolved in 24-48 h. Two (20%) of 10 patients who had open-ended catheters inserted developed a transient rise in postoperative creatinine (1.7 and 3.5 mg/dl, respectively) compared to 0/28 patients who had whistle-tip catheters placed (P<0.001). Both were attributed to postoperative distal ureteral edema, and only one patient required reinsertion of temporary ureteral stents. No patient developed long-term urinary complications or fistulae. Cystourethroscopy and bilateral retrograde ureteral catheterization by gynecologic oncologists is a simple and quick procedure that may facilitate identifying the distal ureter during radical vaginal or abdominal trachelectomy. We favor using 5Fr whistle-tip catheters as they may be associated with less ureteral mucosal trauma and subsequent postoperative edema. The skills needed for this procedure should be available to fellows in gynecologic oncology training.
Identification of the lumbar interspinous spaces by palpation and verified by X-rays.
Tanaka, Kei; Irikoma, Shingo; Kokubo, Sotaro
2013-01-01
Palpation has been shown to be rather inaccurate at identifying lumbar interspinous spaces in neuraxial anesthesia. The aim of this study is to assess the accuracy of the determination of the lumbar interspinous spaces by anesthesiologist's palpation using postoperative X-rays in obstetric patients. We reviewed the anesthetic record and the post-operative abdominal X-rays of the cesarean sections. We indwelled the epidural catheter for post-operative one-shot analgesia. We included combined spinal and epidural anesthesia cases and compared the interspinous level which the anesthesiologist recorded and the epidural catheter insertion level confirmed by abdominal X-ray for each case. We also evaluated the factors (age, body weight, height, Body Mass Index, gestational age, and the type of surgery [planned / emergency]) leading to misidentification of interspinous level. Nine hundred and sixty seven cesarean sections were performed and a total of 835 cases were evaluated. The levels of the puncture documented by the anesthesiologists were in agreement with the actual catheter insertion levels in 563 (67%) cases. When the anesthesiologists aimed at L2-3 level, we found the catheter insertion at L1-2 in 5 cases (4.9%), none of which had any post-operative neurological deficits. No variables evaluated were significantly associated with misidentification of interspinous level by the anesthesiologists. There was a discrepancy between the anesthesiologists' estimation by palpation and the actual catheter insertion level shown in X-rays. It seems to be safer to choose the interspinous level L3-4 or lower in spinal anesthesia. Copyright © 2013 Elsevier Editora Ltda. All rights reserved.
Kampf, Günter; Reise, Gesche; James, Claudia; Gittelbauer, Kirsten; Gosch, Jutta; Alpers, Birgit
2013-01-01
Background: Peripheral venous catheters are frequently used in hospitalized patients but increase the risk of nosocomial bloodstream infection. Evidence-based guidelines describe specific steps that are known to reduce infection risk. However, the degree of guideline implementation in clinical practice is not known. The aim of this study was to determine the use of specific steps for insertion of peripheral venous catheters in clinical practice and to implement a multimodal intervention aimed at improving both compliance and the optimum order of the steps. Methods: The study was conducted at University Hospital Hamburg. An optimum procedure for inserting a peripheral venous catheter was defined based on three evidence-based guidelines (WHO, CDC, RKI) including five steps with 1A or 1B level of evidence: hand disinfection before patient contact, skin antisepsis of the puncture site, no palpation of treated puncture site, hand disinfection before aseptic procedure, and sterile dressing on the puncture site. A research nurse observed and recorded procedures for peripheral venous catheter insertion for healthcare workers in four different departments (endoscopy, central emergency admissions, pediatrics, and dermatology). A multimodal intervention with 5 elements was established (teaching session, dummy training, e-learning tool, tablet and poster, and direct feedback), followed by a second observation period. During the last observation week, participants evaluated the intervention. Results: In the control period, 207 insertions were observed, and 202 in the intervention period. Compliance improved significantly for four of five steps (e.g., from 11.6% to 57.9% for hand disinfection before patient contact; p<0.001, chi-square test). Compliance with skin antisepsis of the puncture site was high before and after intervention (99.5% before and 99.0% after). Performance of specific steps in the correct order also improved (e.g., from 7.7% to 68.6% when three of five steps were done; p<0.001). The intervention was described as helpful by 46.8% of the participants, as neutral by 46.8%, and as disruptive by 6.4%. Conclusions: A multimodal strategy to improve both compliance with safety steps for peripheral venous catheter insertion and performance of an optimum procedure was effective and was regarded helpful by healthcare workers. PMID:24327944
Sociotropic or autonomous personality and problem solving in peritoneal dialysis patients.
Demir, S; Tufan, G; Erem, O
2010-01-01
This study investigated the sociotropic and autonomous personality characteristics and perceived problem solving ability of continuous ambulatory peritoneal dialysis (CAPD) patients, and their relationship with quality of life. The study included 14 CAPD patients and 54 healthy volunteers. Sociotropy and autonomy scores were significantly higher in CAPD patients than in the healthy control group. Among CAPD patients, there was a significant correlation between problem solving and serum phosphate, parathormone levels and erythrocyte sedimentation rate. There was a negative correlation between total dialysis time and sociotropy in CAPD patients, and a positive correlation between general health/pain perception and autonomy. Appropriate medical management, time on dialysis and positive self-perception of health were correlated with better problem solving ability and higher autonomous but lower sociotropic personality styles.
Bellis, Teri James; Billiet, Cassie; Ross, Jody
2011-09-01
Cacace and McFarland (2005) have suggested that the addition of cross-modal analogs will improve the diagnostic specificity of (C)APD (central auditory processing disorder) by ensuring that deficits observed are due to the auditory nature of the stimulus and not to supra-modal or other confounds. Others (e.g., Musiek et al, 2005) have expressed concern about the use of such analogs in diagnosing (C)APD given the uncertainty as to the degree to which cross-modal measures truly are analogous and emphasize the nonmodularity of the CANs (central auditory nervous system) and its function, which precludes modality specificity of (C)APD. To date, no studies have examined the clinical utility of cross-modal (e.g., visual) analogs of central auditory tests in the differential diagnosis of (C)APD. This study investigated performance of children diagnosed with (C)APD, children diagnosed with ADHD (attention deficit hyperactivity disorder), and typically developing children on three diagnostic tests of central auditory function and their corresponding visual analogs. The study sought to determine whether deficits observed in the (C)APD group were restricted to the auditory modality and the degree to which the addition of visual analogs aids in the ability to differentiate among groups. An experimental repeated measures design was employed. Participants consisted of three groups of right-handed children (normal control, n=10; ADHD, n=10; (C)APD, n=7) with normal and symmetrical hearing sensitivity, normal or corrected-to-normal visual acuity, and no family or personal history of disorders unrelated to their primary diagnosis. Participants in Groups 2 and 3 met current diagnostic criteria for ADHD and (C)APD. Visual analogs of three tests in common clinical use for the diagnosis of (C)APD were used (Dichotic Digits [Musiek, 1983]; Frequency Patterns [Pinheiro and Ptacek, 1971]; and Duration Patterns [Pinheiro and Musiek, 1985]). Participants underwent two 1 hr test sessions separated by at least 1 wk. Order of sessions (auditory, visual) and tests within each session were counterbalanced across participants. ANCOVAs (analyses of covariance) were used to examine effects of group, modality, and laterality (Dichotic/Dichoptic Digits) or response condition (auditory and visual patterning). In addition, planned univariate ANCOVAs were used to examine effects of group on intratest comparison measures (REA, HLD [Humming-Labeling Differential]). Children with both ADHD and (C)APD performed more poorly overall than typically developing children on all tasks, with the (C)APD group exhibiting the poorest performance on the auditory and visual patterns tests but the ADHD and (C)APD group performing similarly on the Dichotic/Dichoptic Digits task. However, each of the auditory and visual intratest comparison measures, when taken individually, was able to distinguish the (C)APD group from both the normal control and ADHD groups, whose performance did not differ from one another. Results underscore the importance of intratest comparison measures in the interpretation of central auditory tests (American Speech-Language-Hearing Association [ASHA], 2005 ; American Academy of Audiology [AAA], 2010). Results also support the "non-modular" view of (C)APD in which cross-modal deficits would be predicted based on shared neuroanatomical substrates. Finally, this study demonstrates that auditory tests alone are sufficient to distinguish (C)APD from supra-modal disorders, with cross-modal analogs adding little if anything to the differential diagnostic process. American Academy of Audiology.
Sztain, Jacklynn F; Khatibi, Bahareh; Monahan, Amanda M; Said, Engy T; Abramson, Wendy B; Gabriel, Rodney A; Finneran, John J; Bellars, Richard H; Nguyen, Patrick L; Ball, Scott T; Gonzales, Francis B; Ahmed, Sonya S; Donohue, Michael C; Padwal, Jennifer A; Ilfeld, Brian M
2018-07-01
A continuous adductor canal block provides analgesia after surgical procedures of the knee. Recent neuroanatomic descriptions of the thigh and knee led us to speculate that local anesthetic deposited in the distal thigh close to the adductor hiatus would provide superior analgesia compared to a more proximal catheter location. We therefore tested the hypothesis that during a continuous adductor canal nerve block, postoperative analgesia would be improved by placing the perineural catheter tip 2-3 cm cephalad to where the femoral artery descends posteriorly to the adductor hiatus (distal location) compared to a more proximal location at the midpoint between the anterior superior iliac spine and the superior border of the patella (proximal location). Preoperatively, subjects undergoing total knee arthroplasty received an ultrasound-guided perineural catheter inserted either in the proximal or distal location within the adductor canal in a randomized, subject-masked fashion. Subjects received a single injection of lidocaine 2% via the catheter preoperatively, followed by an infusion of ropivacaine 0.2% (8 mL/h basal, 4 mL bolus, 30 minutes lockout) for the study duration. After joint closure, the surgeon infiltrated the entire joint using 30 mL of ropivacaine (0.5%), ketorolac (30 mg), epinephrine (5 μg/mL), and tranexamic acid (2 g). The primary end point was the median level of pain as measured on a numeric rating scale (NRS) during the time period of 8:00 AM to 12:00 PM the day after surgery. For the primary end point, the NRS of subjects with a catheter inserted at the proximal location (n = 24) was a median (10th, 25th-75th, 90th quartiles) of 0.5 (0.0, 0.0-3.2, 5.0) vs 3.0 (0.0, 2.0-5.4, 7.8) for subjects with a catheter inserted in the distal location (n = 26; P = .011). Median and maximum NRSs were lower in the proximal group at all other time points, but these differences did not reach statistical significance. There were no clinically relevant or statistically significant differences between the treatment groups for any other secondary end point, including opioid consumption and ambulation distance. For continuous adductor canal blocks accompanied by intraoperative periarticular local anesthetic infiltration, analgesia the day after knee arthroplasty is improved with a catheter inserted at the level of the midpoint between the anterior superior iliac spine and the superior border of the patella compared with a more distal insertion closer to the adductor hiatus.
Zisis, Charalambos; Tsirgogianni, Katerina; Lazaridis, George; Lampaki, Sofia; Baka, Sofia; Mpoukovinas, Ioannis; Karavasilis, Vasilis; Kioumis, Ioannis; Pitsiou, Georgia; Katsikogiannis, Nikolaos; Tsakiridis, Kosmas; Rapti, Aggeliki; Trakada, Georgia; Karapantzos, Ilias; Karapantzou, Chrysanthi; Zissimopoulos, Athanasios; Zarogoulidis, Konstantinos
2015-01-01
A chest tube is a flexible plastic tube that is inserted through the chest wall and into the pleural space or mediastinum. It is used to remove air in the case of pneumothorax or fluid such as in the case of pleural effusion, blood, chyle, or pus when empyema occurs from the intrathoracic space. It is also known as a Bülau drain or an intercostal catheter. Insertion of chest tubes is widely performed by radiologists, pulmonary physicians and thoracic surgeons. Large catheters or small catheters are used based on each situation that the medical doctor encounters. In the current review we will focus on the chest drain systems that are in use. PMID:25815304
1983-01-01
7- peripheral intravenous route. CARE OF THE CENTRAL VENOUS CATHETER Central venous catheter insertion requires the follow- ing skin preparation: 1...receiving parenteral nutrition who develop sepsis from central venous catheters may show persistent temperature spikes to 38.9 *C to 40.0 *C every 12-24...hours. Evaluating the central venous catheter as the etiology for febrile episodes is often difficult because many patients have other potential
Lin, J L; Schie, J T; Tseng, C D; Chen, W J; Cheng, T F; Tsou, S S; Chen, J J; Tseng, Y Z; Lien, W P
1995-01-01
Despite similar guidance by local electrogram criteria, catheter ablation of right-sided accessory atrioventricular (AV) pathways by radiofrequency current has been less effective than that of left-sided ones. In order to elucidate the possible diversities in local electrosignal criteria, we systematically analyzed the morphological and timing characteristics of 215 bipolar local electrograms from catheter ablation sites of 65 left-sided accessory AV pathways and of 356 from those of 37 right-sided ones in 92 consecutive patients with Wolff-Parkinson-White syndrome or AV reentrant tachycardia incorporating concealed accessory AV pathways. After stepwise multivariate analysis, we selected the presence of a possible accessory pathway potential, local ventricular activation preceding QRS complex for 20 ms or more during ventricular insertion mapping, and the local retrograde ventriculoatrial (VA) continuity, local retrograde VA interval < or = 50 ms, electrogram stability (left-sided targets only), retrograde accessory pathway potential (right-sided targets only) during atrial insertion mapping, as independent local electrogram predictors for successful ablation of left- and right-sided accessory AV pathways. Combination of all local electrogram predictors could have moderate chance of success (80 and 51%) for the ventricular and atrial insertion ablation of left-sided accessory AV pathways, but only low probability of success (40% in ventricular insertion ablation) or very low sensitivity (12.5% in atrial insertion ablation) for right-sided ones. In conclusion, with the present approach, successful catheter ablation of right-sided accessory AV pathways, compared to left-sided ones, still necessitate a breakthrough in the precision mapping and the efficiency of energy delivery.
Marnejon, Thomas; Angelo, Debra; Abu Abdou, Ahmed; Gemmel, David
2012-01-01
To identify clinically important risk factors associated with upper extremity venous thrombosis following peripherally inserted central venous catheters (PICC). A retrospective case control study of 400 consecutive patients with and without upper extremity venous thrombosis post-PICC insertion was performed. Patient data included demographics, body mass index (BMI), ethnicity, site of insertion, size and lumen of catheter, internal length, infusate, and co-morbidities, such as diabetes mellitus, congestive heart failure, and renal failure. Additional risk factors analyzed were active cancer, any history of cancer, recent trauma, smoking, a history of prior deep vein thrombosis, and recent surgery, defined as surgery within three months prior to PICC insertion. The prevalence of trauma, renal failure, and infusion with antibiotics and total parenteral nutrition (TPN) was higher among patients exhibiting upper extremity venous thrombosis (UEVT), when compared to controls. Patients developing UEVT were also more likely to have PICC line placement in a basilic vein and less likely to have brachial vein placement (P<.001). Left-sided PICC line sites also posed a greater risk (P=.026). The rate of standard DVT prophylaxis with low molecular weight heparin and unfractionated heparin and the use of warfarin was similar in both groups. Average length of hospital stay was almost double among patients developing UEVT, 19.5 days, when compared to patients undergoing PICC line insertion without thrombosis, 10.8 days (t=6.98, P<.001). In multivariate analysis, trauma, renal failure, left-sided catheters, basilic placement, TPN, and infusion with antibiotics, specifically vancomycin, were significant risk factors for UEVT associated with PICC insertion. Prophylaxis with low molecular weight heparin, unfractionated heparin or use of warfarin did not prevent the development of venous thrombosis in patients with PICCs. Length of hospital stay and cost are markedly increased in patients who develop PICC-associated upper extremity venous thrombosis.
Jin, Xiao-dong; Li, Zhong-yi; Luo, Xue-hong; Chen, Zhao-dian; Cai, Song-liang; Xie, Li-ping
2008-06-24
To introduce a method of retrograde ureteric catheter placement via flexible cystoscope , and to evaluate the feasibility and safety of this method. 112 patients, 62 males and 50 females undergoing retrograde ureteropyelography by 2 same physicians in cooperation were randomly divided into two equal groups with 31 males and 25 females each: one group via flexible cystoscope and the other group via rigid cystoscope. The catheterizing time, visual analogue scale (VAS) pain score, gross hematuria rate, and fever rate were compared between these 2 groups. Fifty-five patients underwent ureteric catheter placement successfully via flexible cystoscope (98%, 55/56), while 53 cases were technically successful by rigid cystoscope (95%, 53/56). The inserting time in women patients of the flexible cystoscopy group was (7.6 +/- 1.8) min, significantly shorter than that of the men [(8.0 +/- 1.8) min, P < 0.05]. The inserting time in women patients of the rigid cystoscopy group was (7.4 +/- 1.5) min, significantly shorter than that of the men [(8.2 +/- 1.2) min, P < 0.05]. However, there were not significant differences in the inserting times in both men and women between these 2 groups (both P > 0.05). The VAS pain scores in men and women of the flexible cystoscope group were 3. 5 and 2. 3 respectively, both significantly lower than those of the rigid cystoscopy group (7.2 and 3.3 respectively, both P < 0.05). The gross hematuria rate of the flexible cystoscope group was 8.6% (5/56), significantly lower than that of the rigid cystoscopy group (25.0%, 14/56, P < 0.05). Four patients had a fever after flexible cystoscopy while 6 cases did after rigid cystoscopy, however, without significant difference between these 2 groups (P > 0.05). Retrograde placement of ureteric catheter via flexible cystoscope is safe and reliable as rigid cystoscopy. Meanwhile, inserting ureteric catheter via flexible cystoscope causes the patients less pain and less chance of hematuria.
Air embolism after central venous catheterization.
Kashuk, J L; Penn, I
1984-09-01
Air embolism--the most dangerous complication of central venous catheterization--may occur in several ways. The most frequent is from disconnection of the catheter from the related intravenous tubing. An embolism may present with a sucking sound, tachypnea, air hunger, wheezing, hypotension and a "mill wheel" murmur. A later manifestation is severe pulmonary edema. In a review of 24 patients, the mortality was 50 per cent. Among the survivors, five (42 per cent) had neurologic damage. Immediate treatment includes placing the patient in the left lateral and Trendelenberg positions, administration of oxygen and aspiration of air from the heart. Cardiac massage and emergency cardiopulmonary bypass may be necessary. Most instances can be prevented by inserting the cannula with the patient in the Trendelenberg position, occluding the cannula hub except briefly while the catheter is inserted, fixation of the catheter hub to its connections and occlusive dressing over the track after removal of the catheter.
Attitudes and knowledge of urethral catheters: a targeted educational intervention.
Cohen, Andrew; Nottingham, Charles; Packiam, Vignesh; Jaskowiak, Nora; Gundeti, Mohan
2016-10-01
To assess the training of medical students and their confidence in urethral catheter placement, given growing evidence of unnecessary urology consults and iatrogenic injury. A third-year medical school class was queried about their attitudes and knowledge of catheter placement before and after the Clinical Biennium. The Clinical Biennium introduces hands-on skills prior to clinical clerkships. Urethral catheterisation is one of the skill stations that students rotate through, and urology residents provide a didactic session and supervised simulation. Confidence was self-rated regarding catheter technique, knowledge, troubleshooting, and comfort with placement in the same and opposite gender. Factual questions were posed about proper insertion and malfunctioning catheters. In all, 92 students participated in the initial survey, 41% female and 59% male, and 87% of the students had never placed a catheter. Students desired high confidence in catheter skills (4.4/5). There were no significant differences in responses for those with a desire to pursue urology vs other specialties, or procedural fields compared with non-procedural fields. Prior independent learning was reported by 38% of students and was a predictor for increased confidence across all domains (P < 0.05). In all, 16.7% of students initially identified proper male urethral insertion distance, which improved to 95.6% after the session. Student interest in urology modestly increased after the educational session (P = 0.028). At 3-6 months follow-up, students had performed a median (interquartile range) of 4 (2-7) urethral catheter placements, and 74.2% of students rated training useful or extremely useful. Indeed, 54.8% desired more instruction. Knowledge assessment indicated that 93% of students retained comprehension of proper male urethral insertion distance. Clinical Foley training rarely contradicted instruction from the Clinical Biennium (6.5%). At all time-points, medical student knowledge for troubleshooting catheters was low. Medical students strive for high confidence in urethral catheter placement. Prior targeted education improves confidence and knowledge. Together with clinical experience, these effects are durable up to 6 months. © 2016 The Authors BJU International © 2016 BJU International Published by John Wiley & Sons Ltd.
2014-10-21
lases.11,30,31 The first bound structure of CapD [Protein Data Bank ( PDB ) entry 3G9K] was determined with a di-α-L-Glu ligand.29 The di-α-L-Glu ligand...Article dx.doi.org/10.1021/bi500623c | Biochemistry 2014, 53, 6954−69676956 into the CapD structure ( PDB entry 3G9K29) identified two principal...in capsule anchoring and remodeling makes the enzyme a promising target for anthrax medical countermeasures. Although the structure of CapD is known
Schambye, H T; Pedersen, F B; Wang, P
1992-01-01
Human polymorphonuclear granulocytes (PMN) were tested for migration and phagocytosis after exposure to CAPD solutions and effluents sampled during the first hour of dialysis from patients treated with lactate or bicarbonate based CAPD-solutions. The effluents from the lactate based solutions (Dianeal and Lockolys) reduced the migration and enhanced the phagocytosis compared to values obtained in a standard cell culture medium. Both cell functions increased during the dialysis period. In contrast, the cell-function only changed slightly when 87b, a bicarbonate based CAPD-solution (pH = 7.4, [HCO3-) = 29mM), was employed. During the first 30 minutes, the cells performed at a higher level when exposed to the 87b effluent than when exposed to the lactate effluents. The observations further indicated that optimal conditions for PMNs are at a bicarbonate concentration of less than 20 mM and a lactate concentration of less than 15mM. PMN migration is reduced by both lactate and bicarbonate based CAPD solutions and effluents collected during the first hour of dialysis. The bio-compatibility of CAPD solutions may be improved by combining the lactate and bicarbonate buffering systems in a solution with a concentration of less than 20 mM of bicarbonate and less than 15 mM of lactate.
The role of interventional radiology in management of benign and malignant gynecologic diseases.
Yu, Hyeon; Stavas, Joseph M
2013-10-01
This article focuses on the role of interventional radiology in the therapeutic and diagnostic management of benign and malignant gynecologic conditions. The subspecialty of interventional radiology utilizes minimally invasive advanced image-guided percutaneous techniques in gynecology that include central venous catheter placement, fluid aspiration, drainage catheter placement, tissue biopsy, inferior vena cava filter placement, and pelvic arterial embolization. Central venous catheters, such as ports, peripherally inserted central catheters, and tunneled catheters, are placed for intermediate to long-term intravenous chemotherapy or total parental nutrition or antibiotics. Patients with refractory malignant ascites or pleural effusion from seeding of advanced gynecologic cancers may benefit by percutaneous aspiration of fluid collections or placement of drainage catheters. Postoperative fluid collections including abscess, seroma, or lymphocele are managed by percutaneous drainage catheter insertion. Pelvic, peritoneal, or retroperitoneal masses can be sampled by image-guided percutaneous biopsy or aspiration of fluid to determine a pathologic diagnosis. Certain patients are at risk for deep venous thrombosis with pulmonary embolism and may benefit from an inferior vena cava filter. Patients with uncontrolled postoperative or postpartum bleeding can be effectively managed with emergent transarterial pelvic embolization. Each of the aforementioned interventions with indications, expected benefits, and complications is described including a published literature.
Briggs, Victoria; Pitcher, David; Braddon, Fiona; Fogarty, Damian; Wilkie, Martin
2013-01-01
The central paradigm of effective peritoneal dialysis (PD) is an appropriate standard of PD catheter function. The aim of the project was to develop an effective national PD access audit which would identify an 'appropriate standard' of PD catheter function. The UK Renal Registry collected centre specific information on various PD access outcome measures including catheter functionality and post-insertion complications. The first PD access audit covering England, Northern Ireland and Wales was conducted during April to June 2012 looking at incident dialysis patients in 2011. Forty three data collection spreadsheets were returned from a total of 65 centres describing 917 PD catheter placements. The median age of PD patients was 61 years and 61.5% were male. The proportion of patients initiated on PD in comparison to HD was lower in socially deprived areas. There was a relationship between the timing of nephrology referral and the likelihood of surgical assessment regarding PD catheter placement. Patients with diabetes did not have higher rates of PD catheter failure or of early peritonitis. A comparative PD catheter audit has the potential to provide valuable information on an important patient related outcome measure and lead to an improvement in patient experience. There was wide variation between centres of PD catheter use for late presenting patients. Overall patients were more likely to get a PD catheter if they had been known to the service for more than 1 year. The percutaneous insertion technique was associated with a higher early (less than 2 week) peritonitis rate and more catheter flow problems. Copyright © 2013 S. Karger AG, Basel.
A 6-Fr Guiding Catheter (Slim Guide®) for Use with Multiple Microdevices
Kai, Y.; Ohmori, Y.; Watanabe, M.; Kaku, Y.; Morioka, M.; Hirano, T.; Yano, S.; Kawano, T.; Hamada, J-I.; Kuratsu, J-I.
2013-01-01
Summary A modified technique is required in patients with wide-necked aneurysms whose treatment by the single microcatheter technique is difficult. We developed a 6-Fr guiding catheter (Slim Guide®) that features a large lumen (0.072 inch) for performing the modified technique. To evaluate the usefulness of Slim Guide® we carried out experiments using three types of 6-Fr guiding catheter. In experiment 1, the shaft hardness and kink resistance were compared among three different guiding catheters (Slim Guide®, Launcher®, Envoy®). In experiment 2, we inserted a microballoon catheter and a microcatheter into the three different guiding catheters and recorded the maximal infusion pressure. In experiment 3, we inserted 13 different types of microdevices into the three different guiding catheters and evaluated the resistance of the microdevices. Although the shaft of the Slim Guide® was softer than that of the other two guiding catheters, its kink resistance was comparable. The maximal infusion pressure was significantly lower than with Launcher® or Envoy® catheters. Furthermore, with Slim Guide®, in 136 of 143 microdevice combinations examined (95.1%) there was no resistance; this was true for 125 (87.4%) and 116 (81.1%) combinations using the Launcher® - and the Envoy® guiding catheters, respectively. There was a significant difference between Slim Guide® and the other two guiding catheters with respect to their accommodation of double microsystems (p<0.05). Although the inner diameter of Slim Guide® is slightly larger than of the other two guiding catheters, it significantly increased the combination of microdevices that could be used for the coil embolization of difficult aneurysms. PMID:23472717
A 6-fr guiding catheter (slim guide(®)) for use with multiple microdevices. An experimental study.
Kai, Y; Ohmori, Y; Watanabe, M; Kaku, Y; Morioka, M; Hirano, T; Yano, S; Kawano, T; Hamada, J-I; Kuratsu, J-I
2013-03-01
A modified technique is required in patients with wide-necked aneurysms whose treatment by the single microcatheter technique is difficult. We developed a 6-Fr guiding catheter (Slim Guide(®)) that features a large lumen (0.072 inch) for performing the modified technique. To evaluate the usefulness of Slim Guide(®) we carried out experiments using three types of 6-Fr guiding catheter. In experiment 1, the shaft hardness and kink resistance were compared among three different guiding catheters (Slim Guide(®), Launcher(®), Envoy(®)). In experiment 2, we inserted a microballoon catheter and a microcatheter into the three different guiding catheters and recorded the maximal infusion pressure. In experiment 3, we inserted 13 different types of microdevices into the three different guiding catheters and evaluated the resistance of the microdevices. Although the shaft of the Slim Guide(®) was softer than that of the other two guiding catheters, its kink resistance was comparable. The maximal infusion pressure was significantly lower than with Launcher(®) or Envoy(®) catheters. Furthermore, with Slim Guide(®), in 136 of 143 microdevice combinations examined (95.1%) there was no resistance; this was true for 125 (87.4%) and 116 (81.1%) combinations using the Launcher(®) - and the Envoy(®) guiding catheters, respectively. There was a significant difference between Slim Guide(®) and the other two guiding catheters with respect to their accommodation of double microsystems (p<0.05). Although the inner diameter of Slim Guide(®) is slightly larger than of the other two guiding catheters, it significantly increased the combination of microdevices that could be used for the coil embolization of difficult aneurysms.
Gnass, Silvia Acosta; Barboza, Luisa; Bilicich, Dafne; Angeloro, Pablo; Treiyer, Walter; Grenóvero, Silvia; Basualdo, Juan
2004-08-01
To evaluate the incidence of nosocomial bacteremias related to the use of non-impregnated central venous catheters (CVCs) when only non-technologic strategies were used to prevent them. This was a prospective study of infectious complications of CVCs placed in intensive care unit (ICU) patients from April 1997 to December 2001. The medical-surgical ICU of a tertiary-care, university-affiliated hospital in Argentina. We studied all patients admitted to the ICU using non-impregnated CVCs. Maximal sterile barrier precautions (ie, use of cap, mask, sterile gown, sterile gloves, and large sterile drape), strict handwashing, preparation of the patients' skin with antiseptic solutions, insertion and management of catheters by trained personnel, and continuing quality improvement programs aimed at appropriate insertion and maintenance of catheters were employed. During the study period, 2,525 patients were admitted to the ICU. Eight hundred sixty-eight patients had 1,037 CVCs inserted. The number of CVC-related bloodstream infections (BSIs), acquired in the ICU, was 2.7 per 1,000 CVC-days (13 nosocomial CVC-related BSIs during 4,770 days of CVC use). Microorganisms isolated included methicillin-susceptible Staphylococcus aureus (n = 6), methicillin-resistant S. aureus (n = 2), coagulase-negative methicillin-resistant Staphylococcus (n = 2), Escherichia coli (n = 1), Klebsiella pneumoniae (n = 1), and Enterobacter cloacae (n = 1). A low rate of catheter-related BSI was achieved without antimicrobial-impregnated catheters. The incidence of CVC-associated bacteremias corresponded to the 10th to 20th percentile range of the National Nosocomial Infections Surveillance System hospitals for the same type of ICU.
Peripherally inserted central catheter - insertion
... ed. Philadelphia, PA: Elsevier Saunders; 2014:chap 26. Smith SF, Duell DJ, Martin BC, Gonzalez L, Aebersold M. Central vascular access devices. In: Smith SF, Duell DJ, Martin BC, Gonzalez L, Aebersold ...
Chen, Guan-Chun; Lin, Chia-Hung; Hsieh, Kai-Sheng; Du, Yi-Chun; Chen, Tainsong
2015-01-01
This study proposes virtual-reality (VR) simulator system for double interventional cardiac catheterization (ICC) using fractional-order vascular access tracker and haptic force producer. An endoscope or a catheter for diagnosis and surgery of cardiovascular disease has been commonly used in minimally invasive surgery. It needs specific skills and experiences for young surgeons or postgraduate year (PGY) students to operate a Berman catheter and a pigtail catheter in the inside of the human body and requires avoiding damaging vessels. To improve the training in inserting catheters, a double-catheter mechanism is designed for the ICC procedures. A fractional-order vascular access tracker is used to trace the senior surgeons' consoled trajectories and transmit the frictional feedback and visual feedback during the insertion of catheters. Based on the clinical feeling through the aortic arch, vein into the ventricle, or tortuous blood vessels, haptic force producer is used to mock the elasticity of the vessel wall using voice coil motors (VCMs). The VR establishment with surgeons' consoled vessel trajectories and hand feeling is achieved, and the experimental results show the effectiveness for the double ICC procedures. PMID:26171419
Kaddoum, Roland; Motlani, Faisal; Kaddoum, Romeo N; Srirajakalidindi, Arvi; Gupta, Deepak; Soskin, Vitaly
2014-08-01
One of the controversial management options for accidental dural puncture in pregnant patients is the conversion of labor epidural analgesia to continuous spinal analgesia by threading the epidural catheter intrathecally. No clear consensus exists on how to best prevent severe headache from occurring after accidental dural puncture. To investigate whether the intrathecal placement of an epidural catheter following accidental dural puncture impacts the incidence of postdural puncture headache (PDPH) and the subsequent need for an epidural blood patch in parturients. A retrospective chart review of accidental dural puncture was performed at Hutzel Women's Hospital in Detroit, MI, USA for the years 2002-2010. Documented cases of accidental dural punctures (N = 238) were distributed into two groups based on their management: an intrathecal catheter (ITC) group in which the epidural catheter was inserted intrathecally and a non-intrathecal catheter (non-ITC) group that received the epidural catheter inserted at different levels of lumbar interspaces. The incidence of PDPH as well as the necessity for epidural blood patch was analyzed using two-tailed Fisher's exact test. In the non-ITC group, 99 (54 %) parturients developed PDPH in comparison to 20 (37 %) in the ITC [odds ratio (OR), 1.98; 95 % confidence interval (CI), 1.06-3.69; P = 0.03]. Fifty-seven (31 %) of 182 patients in the non-ITC group required an epidural blood patch (EBP) (data for 2 patients of 184 were missing). In contrast, 7 (13 %) of parturients in the ITC group required an EBP. The incidence of EBP was calculated in parturients who actually developed headache to be 57 of 99 (57 %) in the non-ITC group versus 7 of 20 (35 %) in the ITC group (OR, 2.52; 95 % CI, 0.92-6.68; P = 0.07). The insertion of an intrathecal catheter following accidental dural puncture decreases the incidence of PDPH but not the need for epidural blood patch in parturients.
Peripherally inserted central catheter - flushing
... on a pair of sterile gloves. Remove the cap on the saline syringe and set the cap down on the paper towel. DO NOT let ... It is a good idea to change the caps at the end of your catheter (called the " ...
Nutrient intake during peritoneal dialysis at the Prince of Wales Hospital in Hong Kong.
Wang, Angela Yee-Moon; Sea, Mandy Man-Mei; Ng, Kenway; Kwan, Mandy; Lui, Siu-Fai; Woo, Jean
2007-05-01
Individuals undergoing peritoneal dialysis are at increased risk of developing cardiac disease and malnutrition. A cross-sectional survey. 249 Chinese continuous ambulatory peritoneal dialysis (CAPD) patients were recruited from the Prince of Wales Hospital in Hong Kong. Another 249 age- and sex-matched controls were recruited from an archive of 1,010 individuals with known food frequency questionnaire (FFQ) data. To compare the dietary intake pattern of CAPD patients with controls and evaluate its association with background cardiac disease. Intake of different nutrients was estimated by using a 7-day FFQ. Intake of all nutrients was lower in CAPD patients than controls, with resulting lower overall energy intake. Nutrient intake was decreased further in CAPD patients with background cardiac disease, which corresponded to worse nutritional status. Controlling for age, male sex, body weight, diabetes mellitus, dialysis therapy duration, residual renal function, peritoneal dialysis urea clearance, and Charlson Comorbidity Index score, background cardiac disease was associated independently with less intake of energy and most macronutrients and micronutrients. However, the association between background cardiac disease and energy and most nutrient intake was decreased or even lost when additional adjustment was made for C-reactive protein and serum albumin levels. An FFQ is limited in that nutrient quantitation is not exact and may be underestimated as a result of underreporting by patients. CAPD patients were compared with a control group without cardiovascular disease ascertainment that did not include subjects with diabetes. Chinese CAPD patients had significantly lower nutrient intake than age- and sex-matched controls. The association between cardiac disease and lower dietary macronutrient and micronutrient intake in CAPD patients was mediated in part through systemic inflammation, which also was associated with more malnutrition. More attention should be focused on improving the intake pattern of Chinese CAPD patients.
Complications of intrathecal opioids and bupivacaine in the treatment of "refractory" cancer pain.
Nitescu, P; Sjöberg, M; Appelgren, L; Curelaru, I
1995-03-01
To test the concept that externalized tunneled intrathecal catheters lead to a high risk of complications, such as meningitis and epidural abscess, and therefore should not be used for durations of intrathecal pain treatment of > 1 week. Prospective, cohort, nonrandomized, consecutive, historical control trial. Tertiary care center, institutional practice, hospitalized and ambulatory care. Two hundred adults (107 women, 93 men) with refractory cancer pain treated for 1-575 (median, 33; total, 14,485) days; 79 patients were treated at home for 2-226 (median, 36; total, 4,711) days. All patients had died by the close of the study. Insertion of intrathecal tunneled nylon (Portex) catheters (223 in 200 patients) with Millipore filters. The catheter hubs were securely fixed to the skin with steel sutures. Standardized care after insertion: (a) daily phone contact with the patients, their families, or the nurses in charge; (b) weekly dressing change at the tunnel outlet by the nurses; (c) refilling of the infusion containers by the nurses; (d) exchange of the infusion systems when empty (within 1 month) and of the antibacterial filter once a month by specially instructed Pain Department nurses. All contact between the connections of the syringes, cassettes, and needles with the operator's hands was carefully avoided during filling and refilling of the infusion containers and exchange of the antibacterial filters; no other aseptic precautions were taken. We recorded the rates of perfect function and complications of the systems. The rates of complications recorded in this study with externalized tunneled intrathecal catheters are discussed and compared with the rates reported in the literature with externalized (tunneled and non-tunneled) epidural and intrathecal catheters, as well as with internalized (both epidural and intrathecal) catheters connected to subcutaneous ports, reservoirs, and pumps. The following rates (as a percentage of number of patients) of perfect function and complications of the systems were recorded (the ranges of rates reported in the literature are given in parentheses): perfect function of the system, 93% (31-90%); accidental injury of an unknown epidural tumor followed by an epidural hematoma, 0.5% (0-6%); skin breakdown at the insertion site, 2% (2-50%); postdural puncture headache, 15.5% (10%); external leakage of CSF, 3.5% (4-27%); CSF hygroma ("pseudomeningocele"), 1.5% (4-6.25%); hearing loss and Ménière-like syndrome, 0% (12%); pain on injection, 0% with continuous infusion and 4.5% with intermittent injections (3-36% with intermittent injections); catheter tip dislodgement, 1.5% (6-33%); catheter (system) occlusion, 1% (3-12%); accidental catheter withdrawal, 4% (3-22%); catheter (system) leakage, 1.5% (2.1-26.6%); all mechanical complications, 8.5% (10-44%); local (catheter entry site) infection, 0.5% (2-33%); catheter track infection, 0% (6-25%); epidural abscess, 0% (0.6-25%); meningitis, 0.5% (1-25%); systemic infection, 0% (3%); incidence of all infections (n/treatment days), 1/7,242 (1/168-1/2,446). In our population and with the technique of insertion and care reported here, the use of externalized tunneled intrathecal catheters has not been associated with higher rates of complications when compared with earlier reported rates of externalized epidural catheters and internalized (both epidural and intrathecal) catheters connected to subcutaneously implanted ports, reservoirs, and pumps. The opinion that the use of externalized tunneled intrathecal catheters should be restricted only to patients who need pain treatment for < 1 week (because of the potential risk of infection, particularly meningitis and epidural abscess) is unfounded.
Ohio statewide quality-improvement collaborative to reduce late-onset sepsis in preterm infants.
Kaplan, Heather C; Lannon, Carole; Walsh, Michele C; Donovan, Edward F
2011-03-01
We aimed to reduce late-onset bacterial infections in infants born at 22 to 29 weeks' gestation by using collaborative quality-improvement methods to implement evidence-based catheter care. We hypothesized that these methods would result in a 50% reduction in nosocomial infection. We conducted an interrupted time-series study among 24 Ohio NICUs. The intervention began in September 2008 and continued through December 2009. Sites used the Institute for Healthcare Improvement Breakthrough Series quality-improvement model to facilitate implementation of evidence-based catheter care. Data were collected monthly for all catheter insertions and for at least 10 observations of indwelling catheter care. NICUs also submitted monthly data on catheter-days, patient-days, and episodes of infection. Data were analyzed by using statistical process control methods. During the intervention, NICUs submitted information on 1916 infants. Of the 242 infections reported, 69% were catheter associated. Compliance with catheter-insertion components was >90% by April 2009. Compliance with components of evidence-based indwelling catheter care reached 80.4% by December 2009. There was a significant reduction in the proportion of infants with at least 1 late-onset infection from a baseline of 18.2% to 14.3%. There was a 20% reduction in the incidence of late-onset infection after the intervention, but the magnitude was less than hypothesized, perhaps because compliance with components of evidence-based care of indwelling catheters remained <90%. Because nearly one-third of infections were not catheter associated, improvement may require attention to other aspects of care such as skin integrity and nutrition.
Intravenous insertion site protection: moisture accumulation in intravenous site protectors.
Lee, W E; Vallino, L M
1996-01-01
Stabilizing the intravenous catheter after insertion is a significant part of intravenous therapy. Dislodgments of the cannula from its optimal position in the vein can lead to complications such as phlebitis, thrombophlebitis, infiltration, and infection. Intravenous site protector shields are designed to protect the catheter from impact and tissue trauma at the insertion site. Nurses have requested ventilation in these shields to avoid moisture build up that may increase the risk of infections. To address this issue, experimental laboratory testing was performed to determine if moisture accumulation as evidenced by increased weight of the shield and visible evidence of condensation occurred. No moisture condensation problems with the ventilated intravenous site protectors were found.
Borretta, Lisa; MacDonald, Tamara; Digout, Carol; Smith, Nadine; Fernandez, Conrad V; Kulkarni, Ketan
2018-01-01
The present population-based study evaluates the management and complications of peripherally inserted central catheters (PICC) in all pediatric oncology patients diagnosed in Maritimes, Canada from 2000 to 2014. A total of 107 PICCs were placed in 87 (10.1%) pediatric oncology patients. A high percentage (33% and 44%, respectively) of the first and second PICC lines was associated with complications. Thrombosis, occlusion, and infection were the most frequent complications. Age above 10 years and left body side of insertion were significantly associated with PICC complications. Given the frequent use of PICCs and the high incidence (>33%) of complications, there is a need to mitigate PICC line complications.
[Complications of double j catheters and their endourological management].
Pérez-Fentes, D
2016-10-01
The insertion of a double J catheter (DJ) has widespread, becoming a usual procedure and standard of care in urology. Despite its relative simplicity it is not free from intraoperative risks or problems during the weeks after the implant. Conversely, despite great advances in design of these catheters the ideal material has not been discovered yet, one that is perfectly biocompatible with urine and avoids completely the advent of complications. The range of problems associated with DJs is variable: from mild self-limited dysuria or hematuria to more complex situations with higher risk, such as catheter migration, complete calcification, breakage, obstruction and renal unit loss. The treatment of theses complications must combine maximal efficacy for their resolution with the least possible surgical aggression. Accordingly, the different options of endourological approach become very important and they are the cornerstone for the treatment of the complications associated with ureteral catheters. The objective of this review is to present the main complications derived from the insertion of a DJ, their diagnosis, prevention and treatment, focusing mainly in the different endourological techniques.
Hamada, L; Saito, K; Yoshimura, H; Ito, K
2000-01-01
In this paper, the microwave interstitial antenna with the dielectric load in part near the tip is introduced to realize the tip-heating and to improve the dependence of the heating patterns on the insertion depth. Numerical simulations using the Finite Difference Time Domain (FDTD) method have been conducted at the frequency of 915 MHz for four different configurations of the coaxial-slot antenna inserted into a catheter: the media between the antenna and the catheter are (a) no, (b) a thin air layer, (c) a thin dielectric layer, and (d) a thin air layer and a dielectric load in part near the tip. The diameter of the antenna including the catheter is sufficiently small for minimally invasive therapy. Comparison of the SARs for the four configurations makes it clear that the dielectric-loaded antenna can realize the best tip-heating and suppress the hot spot near the surface of the human body. Dependence of the SAR distributions on the insertion depth of the antenna has also been examined. It is found from the investigation that the dielectric-loaded antenna has little dependence on the insertion depth.
Atypical use of PICC in infants and small children: a unicentric experience.
Bernasconi, Filippo; Zanaboni, Clelia; Dato, Andrea; Dolcino, Andrea; Bevilacqua, Michela; Montagnini, Luigi; Disma, Nicola
2017-11-17
The peripherally inserted central catheters (PICCs) are vascular access devices (VAD) that are increasingly being used in the pediatric population. If a small vein caliber prevents positioning the catheter in the arm, the following step is to position the same catheter in the supraclavicular area, which can be defined as an off-label use or "atypical" approach, first described by Pittiruti. We retrospectively reviewed PICC positioning with puncture-site in the supra-clavicular area ("atypical" PICC insertion) and then tunneled on the chest. Nineteen atypical PICCs were positioned in 18 patients. The median age of patients at the day of implant was 14 months (IQR 3-27 months), and weight 7.5 kg (IQR 4-12 kg). Within this population, 74% of cases scheduled for a typical PICC insertion presented vein caliber too small for this procedure. For this reason, the typical PICC insertion was changed in favor of an atypical PICC procedure. Atypical PICCs were successfully used in 100% of cases without immediate complications. Atypical PICC positioning is a safe and useful alternative to the conventional technique when there is need for a central vascular access device (CVAD) for mid- or long-term therapy.
Álvarez-Baena, L; Duque, P; Ramos, R; Zarain Obrador, L; Fernández-Quero, L
2016-01-01
A peripherally inserted central catheter (PICC) was inserted into a 44-year-old man to provide parenteral nutrition in a protein-calorie malnutrition secondary to a benign pyloric stenosis. On the fifth day while monitoring the catheter, the patient presented with a massive whitish pleural effusion after undergoing gastric endoscopy in order to treat pyloric stenosis. Chylothorax was initially suspected, and the patient was admitted to a recovery unit. Indocyanine green was administered through the PICC, obtaining a greenish discoloration in the pleural effusion 30 min later. This led to the diagnosis of a pleural effusion caused by a vessel perforation due to the PICC, leading to parenteral nutrition extravasation. Thoraco-abdominal computed tomography was performed, which confirmed an innominate vein perforation due to the PICC. PICC insertion may be associated with severe complications, such as central vessel perforation, and therefore the correct position of a central catheter should be always checked. Intravenous computed tomography contrast is the gold standard for central vascular perforation diagnosis. However if a pleural effusion occurs in this context, it is possible to use a dye, which administered intravenously can lead us to the correct diagnosis in situ. Indocyanine green was used for this purpose in this case. Copyright © 2015 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.
Long-term outcome of permanent hemodialysis catheters: a controlled study.
Jean, G; Charra, B; Chazot, C; Vanel, T; Terrat, J C; Hurot, J M
2001-01-01
Hemodialysis tunneled catheters are widely used nowadays. However, their complications, infection and dysfunction, remain much too frequent. Different types of tunneled silicone hemodialysis catheters are available. We prospectively compared the long-term outcome of the two most popular devices, Permcath cuffed double catheter and TwinCath uncuffed twin catheter, both inserted percutaneously. From January 1994 to April 1998, 125 tunneled catheters were inserted in the internal jugular vein of 86 chronic hemodialysis patients, 63 TwinCath MedComp (TC) and 62 Permcath Quinton (PC). They were prospectively followed looking for technical patency, infection and dysfunction rate. TC were used more often for iterative access (52 vs. 25%, p = 0.01) and were inserted more frequently in the left internal jugular vein (59 vs. 16% p < 0.001). Their median technical survival rate was longer (869 vs. 433 days for PC, p < 0.01) with a 1-year patency rate of 80 vs. 53% (p = 0.002). Total catheter extrusion was also slightly less frequent with TC (4.7 vs. 9.6%), but partial extrusion happened more frequently (43 vs. 16%, p = 0.02). No significant difference in infection rate was observed, 0.77 for TC vs. 1.3 local infection/1,000 catheter days; 1.08 vs. 1.30 bacteremia/1,000 catheter days. A persistent catheter thrombosis was observed in 7.9 vs. 20.9% in PC (p = 0.04), the number of dysfunction was 10.5 vs. 24/1,000 days in use (p = 0.0001) and the number of urokinase infusion was 4.4 vs. 12/1,000 days (p = 0.001). PC needed more radiological interventions for dysfunction with endolumenal brushes (4 vs. 0) or fibrin sleeve removal (4 vs. 0). The vena cava thrombosis incidence was not different (2 vs. 3). Although the study was not randomized, TC appears more efficient allowing for a longer patency with a lower dysfunction rate than PC. This was reinforced by less favorable conditions of TC including more left jugular side and more iterative catheters. The cuff does not offer a better bacteriological barrier or protection against extrusion, and the TC seems at a less risk of fibrin sleeves. However, a large randomized study is needed to definitively conclude. Copyright 2001 S. Karger AG, Basel
Catheter-tip force transducer for cardiovascular research
NASA Technical Reports Server (NTRS)
Feldstein, C.; Lewis, G. W.; Silver, R. H.; Culler, V. H.
1975-01-01
Sensor can be installed in left ventricle by means of procedures available for inserting catheter into an artery at body's extremities and manipulating it through vessel and past aortic valve. Metallic tines of device can be used as internal electrode for electrocardiogram.
Hemodialysis tunneled central venous catheters: five-year outcome analysis.
Mandolfo, Salvatore; Acconcia, Pasqualina; Bucci, Raffaella; Corradi, Bruno; Farina, Marco; Rizzo, Maria Antonietta; Stucchi, Andrea
2014-01-01
Tunneled central venous catheters (tCVCs) are considered inferior to arteriovenous fistulas (AVFs) and grafts in all nephrology guidelines. However, they are being increasingly used as hemodialysis vascular access. The purpose of this study was to document the natural history of tCVCs and determine the rate and type of catheter replacement. This was a prospective study of 141 patients who underwent hemodialysis with tCVCs between January 2008 and December 2012. The patients used 154 tCVCs. Standard protocols about management of tCVCs, according to European Renal Best Practice, were well established. All catheters were inserted in the internal jugular vein. Criteria for catheter removal were persistent bloodstream infection, detection of an outbreak of catheter-related bloodstream (CRBS) infections, or catheter dysfunction. Event rates were calculated per 1,000 catheter days; tCVC cumulative survival was estimated by Kaplan-Meier analysis. Catheter replacement occurred in 15 patients (0.29 per 1,000 days); catheter dysfunction was the main cause of replacement (0.18 per 1,000 days), typically within 12 months of surgical insertion. A total of 53 CRBS events in 36 patients were identified (0.82 per 1,000 days); 17 organisms, most commonly Gram-positive pathogens, were isolated; 87% of CVC infections were treated by systemic antibiotics associated with lock therapy. tCVC cumulative survival was 91% at 1 year, 88% at 2 years and 85% at 4 years. Our data show a high survival rate of tCVCs in hemodialysis patients, with low incidence of catheter dysfunction and CRBS events. These data justify tCVC use for hemodialysis vascular access, also as first choice, especially in patients with exhausted peripheral access and limited life expectancy.
Cuerda, Cristina; Joly, Francisca; Corcos, Olivier; Concejo, Javier; Puiggrós, Carolina; Gil, Carmen; Pironi, Loris
2016-02-01
Catheter-related central vein thrombosis (CRVT) is a severe complication of home parenteral nutrition (HPN) that may be clinically manifest or subclinical. The aims of the study were to prospectively investigate the incidence of CRVT in patients on HPN with benign disease and determine the influence of different variables on this complication. A prospective, multicentre, observational study in the Home Artificial Nutrition-Chronic Intestinal Failure ESPEN group was performed. Patients with benign disease starting HPN or already on HPN after the insertion of a new catheter, were recruited and followed up with Color Doppler Duplex Sonography (CDDS) evaluations at baseline, 1 week, 3, 6 and 12 months after catheter insertion. Fisher's exact test was used to calculate the association of different variables (related to the patient, type of catheter, vascular access, insertion method, catheter care and anticoagulant treatment) with CRVT events. Sixty-two patients (31 males, 31 females) aged 50 ± 19 (19-83) years were included and followed for a median 363 days, with an Inter Quartile Range of 180-365 days, and a total of 16,186 catheter-days. Six patients had previous CRVT and 16 had history of thromboembolic disease (pulmonary and mesenteric). Forty one patients were receiving anticoagulant treatment. Fifty two patients had tunneled catheters and 10 implanted ports. Two patients had symptomatic thrombosis at 3 and 12 months of follow-up (2 and 3 weeks after normal routine CDDS evaluation). The incidence of CRVT was 0.045/catheter/year. CRVT was not significantly associated with any of the variables analyzed. The incidence of CRVT in patients on HPN for benign disease followed by CDDS is low in the first year of catheterization. We did not observe any case of asymptomatic CRVT. Based on our data, CDDS seems to have low effectiveness as a screening tool for CRVT in asymptomatic patients on HPN with benign disease. Copyright © 2015 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
Abolfotouh, Mostafa A; Salam, Mahmoud; Bani-Mustafa, Ala’a; White, David; Balkhy, Hanan H
2014-01-01
Background Although intravenous therapy is one of the most commonly performed procedures in hospitalized patients, it remains susceptible to infectious and noninfectious complications. Previous studies investigated peripheral intravenous catheter (PIVC) complications mainly in pediatrics, but apparently none were investigated among Saudi adult populations. The aim of this study was to assess the pattern and complications of PIVCs at King Abdulaziz Medical City (KAMC), Riyadh, Saudi Arabia. Methods An observational prospective cohort study investigated PIVCs pattern and complications among adults with PIVCs, admitted to various wards at KAMC. PIVCs-related clinical outcomes (pain, phlebitis, leaking, and others) were recorded in 12-hour intervals, using the Visual Inspection Phlebitis scale. Density incidence (DI) and cumulative incidence (CI) of complications and their relative risks (RRs) were calculated. Regression analyses were applied and significance limits were set at P<0.05. Results During the study period, 359 adults were included, mounting to 842 PIVCs and 2,505 catheter days. The majority of patients, 276 (76.9%), had medical, chief admission complaints, whereas 83 (23.1%) were trauma/surgical and infectious cases. Complicated catheters were found in 141 (39.3%) patients, with 273 complications (32.4/100 catheters), in 190 complicated catheters (CI =22.56/100 catheters and DI =75.84/1,000 catheter days). Phlebitis ranked first among complications, 148 (CI =17.6%), followed by pain 64 (CI =7.6%), leaking 33 (CI =3.9%), dislodgement 20 (CI =2.4%), and extravasations and occlusion 4 (CI =0.5% each). Phlebitis was predicted with female sex (P<0.001), insertion in fore/upper arm (P=0.024), and infusion of medication (P=0.02). Removal time for PIVCs insertion was not a significant predictor of phlebitis (RR =1.46, P=0.08). Conclusion Incidence of complications in this study was significantly higher than rates in previous studies. Better insertion techniques may be sought to lower the incidences of PIVC complications, thus extending their onset beyond day 3. Changing catheters is recommended when clinically indicated rather than routinely post-72 hours. PMID:25525365
Elsharkawy, Hesham; Saasouh, Wael; Patel, Bimal; Babazade, Rovnat
2018-04-01
Currently, no gold standard method exists for localization of an epidural catheter after placement. The technique described in this report uses pulsed-wave Doppler (PWD) ultrasound to identify intrathecal location of an epidural catheter. A thoracic epidural catheter was inserted after multiple trials with inconclusive aspiration and test dose. Ultrasound PWD confirmed no flow in the epidural space and positive flow in the intrathecal space. A fluid aspirate was positive for glucose, reconfirming intrathecal placement. PWD is a potential tool that can be used to locate the tip of an epidural catheter.
2010-01-01
Background A central venous catheter (CVC) currently represents the most frequently adopted intravenous line for patients undergoing infusional chemotherapy and/or high-dose chemotherapy with hematopoietic stem-cell transplantation and parenteral nutrition. CVC insertion represents a risk for pneumothorax, nerve or arterial punctures. The aim of this prospective observational study was to explore the safety and efficacy of CVC insertion under ultrasound (US) guidance and to confirm its utility in clinical practice in cancer patients. Methods Consecutive adult patients attending the oncology-hematology department were eligible if they had solid or hematologic malignancies and required CVC insertion. Four types of possible complication were defined a priore: mechanical, thrombotic, infection and malfunctioning. The patient was placed in Trendelenburg's position, a 7.5 MHZ puncturing US probe was placed in the supraclavicular site and a 16-gauge needle was advanced under real-time US guidance into the last portion of internal jugular vein. The Seldinger technique was used to place the catheter, which was advanced into the superior vena cava until insertion into right atrium. Within two hours after each procedure, an upright chest X-ray and ultrasound scanning were carried out to confirm the CVC position and to rule out a pneumotorax. CVC-related infections, symptomatic vein thrombosis and malfunctioning were recorded. Results From December 2000 to January 2009, 1,978 CVC insertional procedures were applied to 1,660 consecutive patients. The procedure was performed 580 times in patients with hematologic malignancies and 1,398 times those with solid tumors. A single-needle puncture of the vein was performed on 1,948 of 1,978 procedures (98.48%); only eighteen attempts among 1,978 failed (0.9%). No pneumotorax, no major bleeding, and no nerve puncture were reported; four cases (0.2%) showed self-limiting hematomas. The mean lifespan of CVC was 189.7 +/- 18.6 days (range 7-701). Symptomatic deep-vein thrombosis of the upper limbs developed in 48 patients (2.42%). Catheter-related infections occurred in 197 (9.96%) of the catheters inserted. They were successfully treated with antibiotics and only in 48 (2.9%) patients definitive CVC removal was required for infection and/or thrombosis or malfunctioning. Conclusions This study represents the largest published series of consecutive patients with cancer undergoing CVC insertion under US guidance; this procedure allowed the completion of the therapeutic program for 1,930/1,978 (97.6%) of the catheters inserted. The absence of pneumotorax and other major complications indicates that US guidance should be mandatory for CVC insertion in patients with cancer. PMID:20958986
Eryildirim, Bilal; Tuncer, Murat; Camur, Emre; Ustun, Fatih; Tarhan, Fatih; Sarica, Kemal
2017-10-03
To evaluate the true necessity of open end ureteral catheter insertion in patients with moderate to severe pelvicalyceal system dilation treated with percutaneous nephrolithotomy (PNL) under sonographic guidance. 50 cases treated with PNL under sonographic guidance in prone position for solitary obstructing renal stones were evaluated. Patients were randomly divided into two groups; Group 1: Patients in whom a open end ureteral catheter was inserted prior to the procedure; Group 2: Patients receiving no catheter before PNL. In addition to the duration of the procedure as a whole and also all relevant stages as well, radiation exposure time, hospitalization period, mean nephrostomy tube duration, mean drop in Hb levels and all intra and postoperative complications have been evaluated. Mean size of the stones was 308.5 ± 133.2 mm2. Mean total duration of the PNL procedure in cases with open end ureteral catheter was significantly longer than the other cases (p < 0.001). Evaluation of the outcomes of the PNL procedures revealed no statistically significant difference between two groups regarding the stone-free rates (86% vs 84%). Additionally, there was no significant difference with respect to the duration of nephrostomy tube, hospitalization period and secondary procedures needed, complication rates as well as the post-operative Hb drop levels in both groups (p = 0.6830). Our results indicate that the placement of an open end ureteral catheter prior to a PNL procedure performed under sonographic access may not be indicated in selected cases presenting with solitary obstructing renal pelvic and/or calyceal stones.
van der Kooi, Tjallie; Sax, Hugo; Pittet, Didier; van Dissel, Jaap; van Benthem, Birgit; Walder, Bernhard; Cartier, Vanessa; Clack, Lauren; de Greeff, Sabine; Wolkewitz, Martin; Hieke, Stefanie; Boshuizen, Hendriek; van de Kassteele, Jan; Van den Abeele, Annemie; Boo, Teck Wee; Diab-Elschahawi, Magda; Dumpis, Uga; Ghita, Camelia; FitzGerald, Susan; Lejko, Tatjana; Leleu, Kris; Martinez, Mercedes Palomar; Paniara, Olga; Patyi, Márta; Schab, Paweł; Raglio, Annibale; Szilágyi, Emese; Ziętkiewicz, Mirosław; Wu, Albert W; Grundmann, Hajo; Zingg, Walter
2018-01-01
To test the effectiveness of a central venous catheter (CVC) insertion strategy and a hand hygiene (HH) improvement strategy to prevent central venous catheter-related bloodstream infections (CRBSI) in European intensive care units (ICUs), measuring both process and outcome indicators. Adult ICUs from 14 hospitals in 11 European countries participated in this stepped-wedge cluster randomised controlled multicentre intervention study. After a 6 month baseline, three hospitals were randomised to one of three interventions every quarter: (1) CVC insertion strategy (CVCi); (2) HH promotion strategy (HHi); and (3) both interventions combined (COMBi). Primary outcome was prospective CRBSI incidence density. Secondary outcomes were a CVC insertion score and HH compliance. Overall 25,348 patients with 35,831 CVCs were included. CRBSI incidence density decreased from 2.4/1000 CVC-days at baseline to 0.9/1000 (p < 0.0001). When adjusted for patient and CVC characteristics all three interventions significantly reduced CRBSI incidence density. When additionally adjusted for the baseline decreasing trend, the HHi and COMBi arms were still effective. CVC insertion scores and HH compliance increased significantly with all three interventions. This study demonstrates that multimodal prevention strategies aiming at improving CVC insertion practice and HH reduce CRBSI in diverse European ICUs. Compliance explained CRBSI reduction and future quality improvement studies should encourage measuring process indicators.
Basford, Tavis J; Poenaru, Dan; Silva, Mariana
2003-05-01
Pediatric central venous catheters (CVCs) traditionally have been placed surgically, guided by anatomic landmarks. Increasingly, interventional radiology services are inserting CVCs using ultrasound image guidance. This study compares the frequency of delayed complications in CVCs placed surgically or radiologically in a pediatric oncology population. Data on CVCs placed in one academic institution over 10 years were collected and analyzed retrospectively. Main outcomes assessed were infectious complications, mechanical complications, and premature catheter removal. Ninety-eight CVCs-comprising 52 external tunneled catheters (ETCs) and 46 subcutaneous ports-were assessed in 67 patients. Median patient age was 6.1 years for children with external catheters and 7.8 years for those with ports. Both infectious and mechanical complications were significantly more common among surgically placed ETCs than those placed radiologically (P <.05). Complications per 1,000 catheter days and premature removal showed a trend toward greater frequency among surgical ETCs, although this did not reach statistical significance. No consistent trends were seen in complications among ports. Pediatric patients with CVCs, especially those with external catheters, experience frequent delayed complications. Patients with radiologically inserted ETCs may encounter fewer complications than those with surgically placed ones. This corroborates previous reports in the literature suggesting image-guided CVC placement as a preferable alternative to traditional techniques. Copyright 2003 Elsevier Inc. All rights reserved.
Incidence and outcome of retained Port-A-Cath fragments during removal.
Aworanti, Olugbenga Michael; Linnane, Niall; Tareen, Farhan; Mortell, Alan
2017-07-01
Port-A-Cath devices are frequently used for long-term venous access. We postulate that long-term use predisposes them to getting stuck and retained in a central vein at the time of removal. We aim to report the incidence and outcome of this complication. Between January 2006 and July 2016, a retrospective review of all Port-A-Cath removals that were performed at our centre was conducted. At the time of removal, catheters that could not be removed from the vein were considered retained. During the study period, 107 children had 174 episodes of silicone Sitimplant (Vygon, Ecouen, France) Port-A-Cath insertions. These children required 135 removal episodes and there were 3 (2.2%) instances whereby the catheter fragment was retained. These episodes of retained catheters only occurred in children with factor VIII deficiency (4.1% incidence in this cohort). For each episode of catheter insertion and removal, the catheters had been left in situ for a mean duration of 43 months in children with factor deficiency and no retained fragments, and the mean duration was 91 months in children with factor deficiency and retained catheter fragments (p = 0.0011). Port-A-Caths that are retained after attempted removal is a complication encountered predominantly in catheters that have been in use for a prolonged duration. Furthermore, factor replacement therapy in haemophiliacs may be a risk factor for this complication.
Peritoneal Dialysis Catheter Removal Post-Transplant - A Rare Case of Delayed Bowel Perforation.
Maxted, Andrew P; Davies, Brian; Colliver, Daniel; Williams, Alun; Lunn, Andrew
2017-01-01
Peritoneal dialysis (PD) is a well-established form of renal replacement therapy and the practice of leaving catheters in situ post-transplantation widely accepted. We present a rare complication: a child presenting with anal protrusion of the PD catheter.The patient is an 11-year-old boy with a background of renal dysplasia and congenital cutis laxa. Twenty-three weeks after dialysis was commenced, the patient underwent a renal transplant. Thirteen weeks post-transplant, the patient felt an unusual sensation after defecation. The curled end of the catheter was seen protruding from the anus. He was admitted, and investigations showed stable graft function, with abdominal X ray showing no free air.Intraoperative findings showed a small perforation of the sigmoid colon sealed off by adherence of several small intestinal loops. This was repaired laparoscopically after removal of the distal part of the catheter per rectum. No peritoneal contamination was seen. He was treated with 5 days of intravenous antibiotics and gradual introduction of enteral feeds. His graft function remained stable throughout.Timing of catheter removal varies, from the time of transplantation to over 3 months post-transplantation. Bowel perforation due to PD catheter insertion is rare and tends to occur at the time of insertion. Anal protrusion of a PD catheter in childhood is extremely rare and unrecorded in a pediatric patient with a connective tissue disorder. Our case highlights that serious complications can occur in the period between transplantation and elective PD catheter removal and that, in the immunocompromised patient, signs can be subtle. Copyright © 2017 International Society for Peritoneal Dialysis.
Luhmann, Janet; Hurt, Sarah; Shootman, Mario; Kennedy, Robert
2004-03-01
Peripheral intravenous catheter (PIV) insertion is a common, painful experience for many children in the pediatric emergency department. Although local anesthetics such as injected buffered lidocaine have been shown to be effective at reducing pain and anxiety associated with PIV insertion, they are not routinely used. ELA-Max, a topical local anesthetic, has the advantage of needle-free administration but has not been compared with buffered lidocaine for PIV insertion. To compare the reduction of pain and anxiety during PIV insertion provided by subcutaneous buffered 1% lidocaine or topical ELA-Max in children. A randomized trial in children 4 to 17 years old undergoing PIV insertion with 22-gauge catheters was conducted. Children received either buffered lidocaine or ELA-Max. Buffered lidocaine was administered by using 30-gauge needles to inject 0.1 to 0.2 mL subcutaneously just before PIV insertion. ELA-Max was applied to the skin and occluded with Tegaderm 30 minutes before PIV insertion. Self-reported Visual Analog Scale (VAS) questionnaires (rating on a scale of 1-10; 1 = no pain, anxiety) were completed by patients and their parents before PIV insertion to assess baseline perceptions about pain and anxiety associated with PIV insertion and immediately after PIV insertion to assess pain and anxiety associated with the experience. After PIV insertion, the nurse who inserted the PIV also completed a VAS questionnaire assessing technical difficulty and satisfaction with the local anesthesia. A blinded observer also completed a VAS questionnaire to assess pain and anxiety associated with the PIV insertion. Data were analyzed by using chi2 and t tests. Sixty-nine subjects were enrolled, and questionnaires were competed by all (mean age: 12.1 +/- 4.5 years; 61% female). There were no differences for buffered lidocaine and ELA-Max groups in age, gender, race, prior IV experience, or baseline pain and anxiety. There were no significant differences between buffered lidocaine and ELA-Max in mean pain and anxiety after PIV insertion by patient, parent, and blinded observer ratings. Nurse ratings of technical difficulty, number of PIV-insertion attempts, and satisfaction with local anesthesia also were not significantly different for buffered lidocaine and ELA-Max groups. ELA-Max provided similar pain and anxiety reduction during PIV insertion in children compared with injected buffered lidocaine. Technical difficulty and satisfaction by nurses inserting the PIV also were similar.
Tran, Hoang S; Burrows, Brian J; Zang, William A; Han, David C
2006-09-01
Peripherally inserted central venous catheter (PICC) lines have become a frequently used method of intravenous access for long-term administration of antibiotics, chemotherapy, and parenteral nutrition. Catheter-related complications involving the arterial tree are rare. We report a case of a 25-year-old woman with a history of difficult PICC line placement that presented with an arteriovenous fistula in the left arm. Duplex ultrasound confirmed the diagnosis of a brachial artery-to-brachial vein arteriovenous fistula (AVF), and the patient underwent surgical repair. To our knowledge, this is the first reported case of an AVF resulting from PICC line placement. Correction of AVF is indicated to alleviate symptoms as well as to prevent future complications.
Nurses' guide to early detection of umbilical arterial catheter complications in infants.
Furdon, Susan Arana; Horgan, Michael J; Bradshaw, Wanda Todd; Clark, David A
2006-10-01
Umbilical arterial catheters (UAC) are routinely used in the care of critically ill newborns. Complications related to UACs include vascular compromise, hemorrhage, complications related to malposition, severance of the catheter itself, and infection. This article is Part II in a series dedicated to assessing infants with an umbilical catheter. Part I focused on infants with umbilical venous catheters; this article will focus on the physical assessment relevant to infants with an UAC. Complications related to UACs can occur during any phase of treatment: insertion, while indwelling, or after discontinuing the catheter. Review of clinical signs of complications along with clinical photographs, will assist caregivers in promptly recognizing UAC-related complications.
Crystal structure of Bacillus anthracis transpeptidase enzyme CapD.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, R.; Richter, S.; Zhang, R.
2009-09-04
Bacillus anthracis elaborates a poly-{gamma}-d-glutamic acid capsule that protects bacilli from phagocytic killing during infection. The enzyme CapD generates amide bonds with peptidoglycan cross-bridges to anchor capsular material within the cell wall envelope of B. anthracis. The capsular biosynthetic pathway is essential for virulence during anthrax infections and can be targeted for anti-infective inhibition with small molecules. Here, we present the crystal structures of the {gamma}-glutamyltranspeptidase CapD with and without {alpha}-l-Glu-l-Glu dipeptide, a non-hydrolyzable analog of poly-{gamma}-d-glutamic acid, in the active site. Purified CapD displays transpeptidation activity in vitro, and its structure reveals an active site broadly accessible for poly-{gamma}-glutamatemore » binding and processing. Using structural and biochemical information, we derive a mechanistic model for CapD catalysis whereby Pro{sup 427}, Gly{sup 428}, and Gly{sup 429} activate the catalytic residue of the enzyme, Thr{sup 352}, and stabilize an oxyanion hole via main chain amide hydrogen bonds.« less
Ilcol, Yesim Ozarda; Dönmez, Osman; Yavuz, Mahmut; Dilek, Kamil; Yurtkuran, Mustafa; Ulus, Ismail H
2002-06-01
This study tested whether continuous ambulatory peritoneal dialysis (CAPD) changes free or phospholipid-bound choline concentrations in serum or peritoneal dialysis fluid of patients with end stage renal disease (ESRD). Serum and dialysate choline and phospholipid-bound choline were measured before, during and after 6 h CAPD. Serum choline concentrations were higher in patients with ESRD compared with age-matched controls. CAPD lowered serum choline concentrations significantly although it did not influence phospholipid-bound choline. Choline accumulated in the dialysate, reaching 28.4 +/- 2.7 microM in children and 18.2 +/- 1.4 microM in adults, during six hours CAPD; phospholipid-bound choline increased to 22.9 +/- 2.5 microM and 10.8 +/- 1.4 microM in children and adults, respectively. The total daily loss of choline into the dialysate was 181 +/- 20 micromoles in children and 260 +/- 18 micromoles in adults. CAPD causes a substantial loss of choline into peritoneal dialysates and reduces serum choline concentrations significantly.
Svoboda, A; Lo, Y; Sheu, R; Dumane, V; Rosenzweig, K
2012-06-01
To present our experience using CT to plan and verify intraluminal HDR treatment for a patient with obstructive jaundice. Due to the obstruction's proximity to the small bowel, along with small bowel adhesions from past surgical history, it was imperative to verify source position relative to the bowel before each treatment. Treatment was administered to a total dose of 2000cGy in 5 fractions via a 6F intraluminal catheter inserted into the patient's 14F percutaneous drainage catheter. Graduations on the intraluminal catheter were used to measure the exact length of catheter inserted in to the patient's drainage tube allowing reproducibility. Dummy seeds inserted during CT were identified by iteratively aligning the planning system's 3D reconstruction axis to the catheter at multiple points as it snaked through the liver. Taking in to account the known offset between actual dwell positions and dummy source positions, we determined what dwell positions to activate for planning. CT verification was performed prior to each treatment to insure that the drainage catheter had not moved and that the distance from treatment site to small bowel was adequate. Dummy seeds and anatomical landmarks were identified on the scout image and correlated to the CT. Verification CTs showed remarkable consistency in the day-to-day drainage catheter position. The physician was able to easily identify the small bowel of concern on the CT and determine if a safe distance existed for treatment. The method outlined in this work provides a safe means by which to treat bile duct obstructions using HDR when critical structures are nearby. We were prepared to make real-time adjustments to our treatment plan to account for significant variation, but found it unnecessary to do so in this particular case. © 2012 American Association of Physicists in Medicine.
Mawar, Shashi; Gupta, Sanjay; Mahajan, Sandeep
2012-08-01
Peritonitis in patients on continuous ambulatory peritoneal dialysis (CAPD) is the leading cause of technique failure. Information on the impact of non-compliance in performing CAPD exchange on peritonitis is limited. We aimed to find the prevalence of non-compliance to the CAPD procedure and its influence on the incidence of peritonitis. This observational study included 30 adult patients undergoing CAPD. The CAPD exchange procedure was observed at home and assessed as per the structured checklist and categorized into poor, average and good compliance. The compliance was correlated with the episodes of peritonitis in previous 1 year. The patients' mean age was 52 ± 13 years and the mean duration of CAPD was 2.1 ± 0.9 years. Only 16.5% of patients were good performers, while 67% were average performers, and 16.5% were poor performers. The technique skill was similar across all the steps of the procedure. The most common improperly performed steps were: not putting on a face mask in 68%, not flushing the tubing system in 60%, and not washing hands in 24%. Poor adherence to procedure was independent of age, gender, education and duration of dialysis. Ten episodes of peritonitis occurred in 5 patients over 1-year period. Peritonitis occurred in 60% of poor performers, whereas fully compliant patients had no peritonitis. Also 40% of the poorly compliant patients had multiple episodes of peritonitis. Poor compliance in performing the CAPD procedure is a modifiable risk factor for peritonitis. Adherence to recommended aseptic technique is the cornerstone of peritonitis prevention.
2009-01-01
Introduction Spinal cord injury patients are at risk for developing unusual complications such as autonomic dysreflexia while changing suprapubic cystostomy. We report a male patient with spina bifida in whom the Foley catheter was placed in the urethra during change of suprapubic cystostomy with serious consequences. Case presentation A male patient, born in 1972 with spina bifida and paraplaegia, underwent suprapubic cystostomy in 2003 because of increasing problems with urethral catheter. The patient would come to spinal unit for change of suprapubic catheter every four to six weeks. Two days after a routine catheter change in November 2009, this patient woke up in the morning and noticed that the suprapubic catheter had come out. He went straight to Accident and Emergency. The suprapubic catheter was changed by a health professional and this patient was sent home. But the suprapubic catheter did not drain urine. This patient developed increasing degree of pain and swelling in suprapubic region. He did not pass any urine per urethra. He felt sick and came to spinal unit five hours later. About twenty ml of contrast was injected through suprapubic catheter and X-rays were taken. The suprapubic catheter was patent; the catheter was not blocked. The Foley catheter could be seen going around in a circular manner through the urinary bladder into the urethra. The contrast did not opacify urinary bladder; but proximal urethra was seen. The tip of Foley catheter was lying in proximal urethra. The balloon of Foley catheter had been inflated in urethra. When the balloon of Foley catheter was deflated, this patient developed massive bleeding per urethra. A sterile 22 French Foley catheter was inserted through suprapubic track. The catheter drained bloody urine. He was admitted to spinal unit and received intravenous fluids and meropenem. Haematuria subsided after 48 hours. The patient was discharged home a week later in a stable condition. Conclusion This case shows that serious complications can occur during change of suprapubic catheter in patients with neuropathic bladder. After inserting a new catheter, health professionals should observe spinal cord injury patients for at least thirty minutes and ensure that (1) suprapubic catheter drains clear urine; (2) patients do not develop abdominal spasm or discomfort; (3) symptoms and signs of sepsis or autonomic dysreflexia are absent. PMID:20062546
Vaidyanathan, Subramanian; Hughes, Peter L; Soni, Bakul M; Oo, Tun; Singh, Gurpreet
2009-12-22
Spinal cord injury patients are at risk for developing unusual complications such as autonomic dysreflexia while changing suprapubic cystostomy. We report a male patient with spina bifida in whom the Foley catheter was placed in the urethra during change of suprapubic cystostomy with serious consequences. A male patient, born in 1972 with spina bifida and paraplaegia, underwent suprapubic cystostomy in 2003 because of increasing problems with urethral catheter. The patient would come to spinal unit for change of suprapubic catheter every four to six weeks. Two days after a routine catheter change in November 2009, this patient woke up in the morning and noticed that the suprapubic catheter had come out. He went straight to Accident and Emergency. The suprapubic catheter was changed by a health professional and this patient was sent home. But the suprapubic catheter did not drain urine. This patient developed increasing degree of pain and swelling in suprapubic region. He did not pass any urine per urethra. He felt sick and came to spinal unit five hours later. About twenty ml of contrast was injected through suprapubic catheter and X-rays were taken. The suprapubic catheter was patent; the catheter was not blocked. The Foley catheter could be seen going around in a circular manner through the urinary bladder into the urethra. The contrast did not opacify urinary bladder; but proximal urethra was seen. The tip of Foley catheter was lying in proximal urethra. The balloon of Foley catheter had been inflated in urethra. When the balloon of Foley catheter was deflated, this patient developed massive bleeding per urethra. A sterile 22 French Foley catheter was inserted through suprapubic track. The catheter drained bloody urine. He was admitted to spinal unit and received intravenous fluids and meropenem. Haematuria subsided after 48 hours. The patient was discharged home a week later in a stable condition. This case shows that serious complications can occur during change of suprapubic catheter in patients with neuropathic bladder. After inserting a new catheter, health professionals should observe spinal cord injury patients for at least thirty minutes and ensure that (1) suprapubic catheter drains clear urine; (2) patients do not develop abdominal spasm or discomfort; (3) symptoms and signs of sepsis or autonomic dysreflexia are absent.
Image-guided Ommaya reservoir insertion for intraventricular chemotherapy: a retrospective series.
Lau, Jonathan C; Kosteniuk, Suzanne E; Macdonald, David R; Megyesi, Joseph F
2018-03-01
Ayub Ommaya proposed a surgical technique for subcutaneous reservoir and pump placement in 1963 to allow access to intraventricular cerebrospinal fluid (CSF). Currently, the most common indication for Ommaya reservoir insertion (ORI) in adults is for patients with hematologic or leptomeningeal disorders requiring repeated injection of chemotherapy into the CSF space. Historically, the intraventricular catheter has been inserted blindly based on anatomical landmarks. The purpose of this study was to examine short-term complication rates with ORI with image guidance (IG) and without image guidance (non-IG). We retrospectively evaluated all operative cases of ORI from 2000 to 2014 by the senior author. Patient demographic data, surgical outcomes, and peri-operative complications were collected. Accurate placement and early (30-day) morbidity or mortality were considered primary outcomes. Fifty-five consecutive patients underwent ORI by the senior author over the study period (43.5 ± 16.6 years; 40.0% female). Indications for placement included acute lymphoblastic leukemia, diffuse large B-cell lymphoma, and leptomeningeal carcinomatosis. There were seven (12.7%) total complications: three (37.5%) with no-IG versus four (8.5%) with IG. Catheter malpositions were significantly higher in the non-IG group at 37.5% compared to 2.1%. Catheters were also more likely to require multiple passes with non-IG at 25% compare to 0% with IG. There were no early infections in either group. We demonstrate improved accuracy and decreased complications using an image-guided approach compared with a traditional approach. Our results support routine use of intra-operative image guidance for proximal catheter insertion in elective ORI for intraventricular chemotherapy.
Santos, Clara; Pérez-Fontán, Miguel; Rodríguez-Carmona, Ana; Calvo-Rodríguez, María; López-Muñiz, Andrés; López-Calviño, Beatriz; García-Falcón, Teresa
2016-01-01
♦ Peritoneal catheter tunnel and exit-site infection (TESI) complicates the clinical course of peritoneal dialysis (PD) patients. Adherence to recommendations for catheter insertion, exit-site care, and management of Staphylococcus aureus (SAu) carriage reduces, but does not abrogate the risk of these infections. ♦ To reappraise the risk profile for TESI in an experienced center with a long-term focus on management of SAu carriage and a low incidence of these infections. ♦ Following a retrospective, observational design, we investigated 665 patients incident on PD. The main study variable was survival to the first episode of TESI. We considered selected demographic, clinical, and technical variables, applying multivariate strategies of analysis. ♦ The overall incidence of TESI was 1 episode/68.5 patient-months. Staphylococcus aureus carriage disclosed at inception of PD (but not if observed sporadically during follow-up) (hazard ratio [HR] 1.53, p = 0.009), PD started shortly after catheter insertion (HR 0.98 per day, p = 0.011), PD after kidney transplant failure (HR 2.18, p = 0.017), lower hemoglobin levels (HR 0.88 per g/dL, p = 0.013) and fast peritoneal transport rates (HR 2.92, p = 0.03) portended an increased risk of TESI. Delaying PD ≥ 30 days after catheter insertion markedly improved the probability of TESI. Carriage of methicillin-resistant SAu since the start of PD was associated with a high incidence of TESI by these bacteria. On the contrary, resistance to mupirocin did not predict such a risk, probably due to the use of an alternative regime in affected patients. ♦ Adherence to current recommendations results in a low incidence of TESI in PD patients. Interventions on specific risk subsets have a potential to bring incidence close to negligible levels. Despite systematic screening and management, SAu carriage is still a predictor of TESI. Antibiotic susceptibility patterns may help to refine stratification of the risk of TESI by these bacteria. Early insertion of the peritoneal catheter should be considered whenever possible, to reduce the risk of later TESI. Copyright © 2016 International Society for Peritoneal Dialysis.
Nagao, Sayaka; Saida, Yoshihisa; Enomoto, Toshiyuki; Takahashi, Asako; Higuchi, Tadashi; Moriyama, Hodaka; Niituma, Toru; Watanabe, Manabu; Asai, Koji; Kusachi, Shinya
2018-05-16
Here we report a prospective study on whether a temporary suprapubic catheter (SPC) can be safely inserted as a substitute for transurethral balloon catheterization during laparoscopy-assisted colectomy. Our subjects included 52 cases who gave informed consent to have an SPC inserted. These subjects were selected from cases who underwent laparoscopy-assisted surgery for primary colorectal cancer from October 2014 to August 2015. An SPC was inserted into 45 of the original 52 cases. The median surgical duration was 220 min (range, 11-438 min), and the SPC insertion was performed at a median of 133 min (range, 9-384 min) after the start of surgery. Insertion required a median duration of 116 s. In one case (2.2%), the bladder was perforated by the paracentesis needle, and in two cases (4.4%), hematuria was observed at the time of insertion; however, surgery was completed without any incident in these three cases. Six of the remaining 42 cases (13.3%) demonstrated neither micturition desire nor independent urination on the day the catheter was clamped. In these cases, the clamp was released two to four times, and draining of an average of 586-mL urine, micturition desire, and independent urination were confirmed 2-4 days later. Transurethral balloon catheterization is a simple procedure that is commonly used on surgical patients, but it can cause pain, discomfort, and infection. In contrast, SPC insertion is a procedure that avoids crossing the urethra and its associated disadvantages. Here we were able to demonstrate that the procedure can be safely used in laparoscopic surgery patients. © 2018 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.
Zhao, Ning; Zhang, Jiale; Jiang, Ting; Chen, Xia; Wang, Jianning; Ding, Chengzhi; Liu, Fen; Qian, Kejian; Jiang, Rong
2017-02-01
To analyze the incidence and its risk factors of peripherally inserted central venous catheter related upper extremity deep venous thrombosis (PICC-UEDVT) in intensive care unit (ICU). Clinical data of the patients received PICCs in ICU of the First Affiliated Hospital of Nanchang University from August 2013 to August 2016 were retrospectively analysed. The inclusion criteria in the study included: the age > 18 years old, catheter indwelling time > 1 week and the complete relevant information. The gender, age, history of deep venous thrombosis (DVT) and PICC; number of illness involved organs; complicated with hypertension, diabetes, infection or not; and acute physiology and chronic health evaluation II (APACHE II), duration of mechanical ventilation; D-dimer, platelet count (PLT), and activated partial thromboplastin time (APTT) were recorded. According to the occurrence of PICC-UEDVT, univariate analysis was performed to identify the risk factors of PICC-UEDVT and variables with statistical difference were selected to do multivariate binary logistic regression analysis for the confirmable independence risk factors. Six patients of the 61 cases occurred PICC-UEDVT with the occurrence rate of 9.8%. Time of occurrence was 9 days, 14 days (2 cases), 22 days, 28 days, 62 days after inserted catheter respectively. Univariate analysis demonstrated that previous DVT, D-dimer and big diameter PICC were risk factors associated with PICC-UEDVT [the previous DVT: 50.00% vs. 7.27%, P = 0.017; D-dimer > 5 mg/L: 66.67% vs. 18.18%, P = 0.021; 5F catheter: 83.33% vs. 29.09%, P = 0.016]. It was shown by multivariate logistic regression analysis that the previous DVT [odds ratio (OR) = 20.539, 95% confidence interval (95%CI) = 1.733-243.875, P = 0.017] and increasing size of catheter (OR = 18.070, 95%CI = 1.317-247.875, P = 0.030) were independent risk factors associated with the development of PICC-UEDVT. For critical patients with a history of DVT and D-dimer > 5 mg/L, especially for those with the catheter placement over 14 days in ICU, clinical staffs should remain on high alert for the development of PICC-UEDVT and take early effective measures to prevent it. Meanwhile the patient's vascular conditions should be precisely assessed using ultrasound before insertion, and the appropriate catheter size be selected to reduce the incidence of PICC-UEDVT. Color Doppler ultrasonography should be used for dynamic monitoring during the indwelling of PICC, so that PICC-UEDVT can be found as early as possible.
Update on voiding dysfunction managed with suprapubic catheterization
2017-01-01
As the population ages the prevalence of long-term urinary catheters, especially in the elderly, is going to increase. Urinary catheters are usually placed to manage urinary retention or incontinence that cannot be managed any other way. There is significant morbidity associated with an indwelling catheter. The commonest problems are catheter blockages, infection and bladder stones. These will occur with a similar incidence with either a suprapubic or a urethral catheter. Urethral complications such as strictures, scrotal infection and erosion are less common with suprapubic catheterization (SPC). However the benefit of having a SPC needs to be balanced against the risks involved in inserting the catheter suprapubically. Patient reported symptoms show that a SPC is more comfortable and better tolerated than a urethral catheter. However there needs to be more research into developing better catheters that reduce the frequency of urinary infections and blockages and hence catheter morbidity. PMID:28791237
Newton, Terry; Still, Joseph M; Law, Edward
2002-04-01
A retrospective study was designed to compare the incidence of urinary tract infections during two different time periods in burn patients treated with two different types of Foley catheters. In time period 1, latex catheters present on admission were not changed. In time period 2, catheters were replaced on admission with silver alloy-impregnated catheters. In time period 1, the rate of symptomatic urinary tract infections was 7.2 per 1,000 catheter-days. In time period 2, the rate was 4.4 per 1,000 catheter-days. Results, compared using Fisher's exact test, revealed a statistically significant P value of .029. The use of silver-impregnated catheters significantly lowered the rate of urinary tract infection at our burn center.
[Peripherally inserted central catheter antibiotic therapy for cystic fibrosis patients].
Betegnie, A-L; Cracowski, C; Bedouch, P; Segond, C; Robein-Dobremez, M-J; Pin, I; Allenet, B
2014-11-01
Peripherally inserted central catheters (PICC) are more and more used for intravenous antibiotic infusions in cystic fibrosis (CF) patients in the Grenoble area (France). The aim of this study was to assess the use of this technique in this indication. 1. Retrospective evaluation of 102 consecutive PICC insertions over 3years and the incidence of adverse events during the therapy. 2. Prospective evaluation of 12 patient's satisfaction and their nurses over a 3-month period. 3. Comparative analysis of single domiciliary treatment costs using PICC versus peripheral catheter (PC). 102 PICC insertions were attempted in 31 patients. Seven failures and 7 complications occurred during the treatment requiring removal of the PICC, i.e. an overall success rate of 86.2% (88/102). Pain during PICC introduction was 4.2/10 (visual analogical scale). Mean satisfaction levels during therapy were 9.3/10 for patients and 8.7/10 for nurses. Compared with PC, all the patients said that PICC was "more comfortable". Differential costs of treatment with PC and with PICC at home were estimated at 57.15€ and 590.16€ respectively. PICC is an alternative to CP for intravenous antibiotherapy in CF patients, providing better safety and comfort. PICC use should be promoted in this indication. Copyright © 2013 SPLF. Published by Elsevier Masson SAS. All rights reserved.
Miura, Fumihiko; Takada, Tadahiro; Ochiai, Takenori; Asano, Takehide; Kenmochi, Takashi; Amano, Hodaka; Yoshida, Masahiro
2006-04-01
Massive intraabdominal hemorrhage sometimes requires urgent hemostatic surgical intervention. In such cases, its rapid stabilization is crucial to reestablish a general hemodynamic status. We used an aortic occlusion balloon catheter in patients with massive intraabdominal hemorrhage occurring after hepato-pancreato-biliary surgery. An 8-French balloon catheter was percutaneously inserted into the aorta from the femoral artery, and the balloon was placed just above the celiac artery. Fifteen minutes inflation and 5 minutes deflation were alternated during surgery until the bleeding was surgically controlled. An aortic occlusion balloon catheter was inserted on 13 occasions in 10 patients undergoing laparotomy for hemostasis of massive hemorrhage. The aorta was successfully occluded on 12 occasions in nine patients. Both systolic pressure and heart rate were normalized during aortic occlusion, and the operative field became clearly visible after adequate suction of leaked blood. Bleeding sites were then easily found and controlled. Hemorrhage was successfully controlled in 7 of 10 patients (70%), and they were discharged in good condition. The aortic occlusion balloon catheter technique was effective for easily controlling massive intraabdominal bleeding by hemostatic procedure after hepato-pancreato-biliary surgery.
Phlebitis and infiltration: vascular trauma associated with the peripheral venous catheter
Braga, Luciene Muniz; Parreira, Pedro Miguel; Oliveira, Anabela de Sousa Salgueiro; Mónico, Lisete dos Santos Mendes; Arreguy-Sena, Cristina; Henriques, Maria Adriana
2018-01-01
ABSTRACT Objective: to determine the incidence rate and risk factors for the nursing-sensitive indicators phlebitis and infiltration in patients with peripheral venous catheters (PVCs). Method: cohort study with 110 patients. Scales were used to assess and document phlebitis and infiltration. Socio-demographic variables, clinical variables related to the PVC, medication and hospitalization variables were collected. Descriptive and inferential analysis and multivariate logistic models were used. Results: the incidence rate of phlebitis and infiltration was respectively 43.2 and 59.7 per 1000 catheter-days. Most PVCs with these vascular traumas were removed in the first 24 hours. Risk factors for phlebitis were: length of hospital stay (p=0.042) and number of catheters inserted (p<0.001); risk factors for infiltration were: piperacillin/tazobactan (p=0.024) and the number of catheters inserted (p<0.001). Conclusion: the investigation documented the incidence of nursing-sensitive indicators (phlebitis and infiltration) and revealed new risk factors related to infiltration. It also allowed a reflection on the nursing care necessary to prevent these vascular traumas and on the indications and contraindications of the PVC, supporting the implementation of the PICC as an alternative to PVC. PMID:29791668
Emergent Start Peritoneal Dialysis for End-Stage Renal Disease: Outcomes and Advantages.
Nayak, K Shivanand; Subhramanyam, Sreepada V; Pavankumar, Navva; Antony, Sinoj; Sarfaraz Khan, M A
2018-01-01
Initiating renal replacement therapy in late referred patients with central venous catheter (CVC) hemodialysis (HD) causes serious complications. In urgent start peritoneal dialysis, initiating peritoneal dialysis (PD) within 14 days of catheter insertion still needs HD with CVC. We initiated Emergent start PD (ESPD) with Automated PD (APD) at our center within 48 h from the time of presentation. A prospective, case-controlled, intention-to-treat study with 56 patients was conducted between March 2016 and August 2017. Group A (24 patients) underwent conventional PD 14 days after catheter insertion. Group B (32 patients), underwent ESPD with APD. Exit site leak (ESL), catheter blockage, and peritonitis at 90 days were primary outcomes. Technique survival was secondary outcome. Baseline characteristics were similar with 3 episodes of ESLs (9.4%) in the study group and none in the control group (p = 0.123). Catheter blockage (16.7%-Group A, 25%-Group B) and peritonitis (none vs. 9.4% in study group) were similar in terms of statistical details just as technique survival (95%-Group A, 88.2%-Group B at 90 days). ESPD with APD in the unplanned patient is an appropriate approach. © 2018 S. Karger AG, Basel.
Mitchell, Brett G; Fasugba, Oyebola; Gardner, Anne; Koerner, Jane; Collignon, Peter; Cheng, Allen C; Graves, Nicholas; Morey, Peter; Gregory, Victoria
2017-11-28
Despite advances in infection prevention and control, catheter-associated urinary tract infections (CAUTIs) are common and remain problematic. A number of measures can be taken to reduce the risk of CAUTI in hospitals. Appropriate urinary catheter insertion procedures are one such method. Reducing bacterial colonisation around the meatal or urethral area has the potential to reduce CAUTI risk. However, evidence about the best antiseptic solutions for meatal cleaning is mixed, resulting in conflicting recommendations in guidelines internationally. This paper presents the protocol for a study to evaluate the effectiveness (objective 1) and cost-effectiveness (objective 2) of using chlorhexidine in meatal cleaning prior to catheter insertion, in reducing catheter-associated asymptomatic bacteriuria and CAUTI. A stepped wedge randomised controlled trial will be undertaken in three large Australian hospitals over a 32-week period. The intervention in this study is the use of chlorhexidine (0.1%) solution for meatal cleaning prior to catheter insertion. During the first 8 weeks of the study, no hospital will receive the intervention. After 8 weeks, one hospital will cross over to the intervention with the other two participating hospitals crossing over to the intervention at 8-week intervals respectively based on randomisation. All sites complete the trial at the same time in 2018. The primary outcomes for objective 1 (effectiveness) are the number of cases of CAUTI and catheter-associated asymptomatic bacteriuria per 100 catheter days will be analysed separately using Poisson regression. The primary outcome for objective 2 (cost-effectiveness) is the changes in costs relative to health benefits (incremental cost-effectiveness ratio) from adoption of the intervention. Results will be disseminated via peer-reviewed journals and presentations at relevant conferences.A dissemination plan it being developed. Results will be published in the peer review literature, presented at relevant conferences and communicated via professional networks. Ethics approval has been obtained. 12617000373370, approved 13/03/2017. Protocol version 1.1. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
The effect of closed system suction on airway pressures when using the Servo 300 ventilator.
Frengley, R W; Closey, D N; Sleigh, J W; Torrance, J M
2001-12-01
To measure airway pressures during closed system suctioning with the ventilator set to three differing modes of ventilation. Closed system suctioning was conducted in 16 patients following cardiac surgery. Suctioning was performed using a 14 French catheter with a vacuum level of -500 cmH2O through an 8.0 mm internal diameter endotracheal tube. The lungs were mechanically ventilated with a Servo 300 ventilator set to one of three ventilation modes: volume-control, pressure-control or CPAP/pressure support. Airway pressures were measured via a 4 French electronic pressure transducer in both proximal and distal airways. Following insertion of the suction catheter, end-expiratory pressure increased significantly (p < 0.001) in both pressure-control and volume-control ventilation. This increase was greatest (p = 0.018) in volume-control mode (2.7 +/- 1.7 cmH2O). On performing a five second suction, airway pressure decreased in all modes, however the lowest airway pressure in volume-control mode (-4.9 +/- 4.0 cmH2O) was significantly (p = 0.001) less than the lowest airway pressure recorded in either pressure-control (0.8 +/- 1.9 cmH2O) or CPAP/pressure support (0.4 +/- 2.8 cmH2O) modes. In CPAP/pressure support mode, 13 of the 16 patients experienced a positive pressure 'breath' at the end of suctioning with airway pressures rising to 21 +/- 1.6 cmH2O. Closed system suctioning in volume control ventilation may result in elevations of end-expiratory pressure following catheter insertion and subatmospheric airway pressures during suctioning. Pressure control ventilation produces less elevation of end-expiratory pressure following catheter insertion and is less likely to be associated with subatmospheric airway pressures during suctioning. CPAP/pressure support has no effect on end-expiratory pressure following catheter insertion and subatmospheric airway pressures are largely avoided during suctioning.
Peripherally Inserted Central Catheter-Related Infections in a Cohort of Hospitalized Adult Patients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bouzad, Caroline, E-mail: caroline.bouzad@gmail.com; Duron, Sandrine, E-mail: duronsandrine@yahoo.fr; Bousquet, Aurore, E-mail: aurorebousquet@yahoo.fr
PurposeTo determine the incidence and the risks factors of peripherally inserted central catheter (PICC)-related infectious complications.Materials and MethodsMedical charts of every in-patient that underwent a PICC insertion in our hospital between January 2010 and October 2013 were reviewed. All PICC-related infections were recorded and categorized as catheter-related bloodstream infections (CR-BSI), exit-site infections, and septic thrombophlebitis.ResultsNine hundred and twenty-three PICCs were placed in 644 unique patients, mostly male (68.3 %) with a median age of 58 years. 31 (3.4 %) PICC-related infections occurred during the study period corresponding to an infection rate of 1.64 per 1000 catheter-days. We observed 27 (87.1 %) CR-BSI, corresponding tomore » a rate of 1.43 per 1000 catheter-days, 3 (9.7 %) septic thrombophlebitis, and 1 (3.2 %) exit-site infection. Multivariate logistic regression analysis showed a higher PICC-related infection rate with chemotherapy (odds ratio (OR) 7.2–confidence interval (CI) 95 % [1.77–29.5]), auto/allograft (OR 5.9–CI 95 % [1.2–29.2]), and anti-coagulant therapy (OR 2.2–95 % [1.4–12]).ConclusionChemotherapy, auto/allograft, and anti-coagulant therapy are associated with an increased risk of developing PICC-related infections.Clinical AdvanceChemotherapy, auto/allograft, and anti-coagulant therapy are important predictors of PICC-associated infections. A careful assessment of these risk factors may be important for future success in preventing PICC-related infections.« less
Egilmez, Tulga; Aridogan, I Atilla; Yachia, Daniel; Hassin, David
2006-04-01
To determine the efficacy of intraurethral metal stents in preventing or eradicating urinary-tract infections (UTI) during the management of bladder outlet obstruction (BOO) by comparing the frequency and nature of the infections with indwelling-catheter-associated UTI. The SAS relative-risk test was used to compare the risks of UTI in 76 patients with temporary urethral stents, 60 patients with BOO who had never been catheterized nor stented, and 34 patients with a permanent indwelling urethral catheter (PIUC). Infection was assessed 1 month after placement of the devices. Scanning electron microscopy (SEM) of the proximal and distal pieces of the stents removed from five patients with and five patients without UTI was carried out in a search for predisposing changes on the surfaces. After insertion of the catheter, UTI developed in 79.4% of the patients who originally had sterile urine. However, after insertion of the stent, UTI developed in only 40.9% of the patients with sterile urine. In 21 (44.6%) of the catheterized patients who had infected urine, UTI was eradicated after stent insertion. The SEM analysis of the stents showed that a thick organic layer had formed only on the infected devices but with no sign of erosion. Urinary infection is a significant problem in patients with PIUC but is significantly less frequent and less severe in patients with urethral stents. This advantage of stents over the conventional urethral catheter, in addition to their obvious convenience for the patient, make them good alternatives to reduce the risk of UTI.
Coolman, B R; Marretta, S M; Kakoma, I; Wallig, M A; Coolman, S L; Paul, A J
1998-12-01
The purpose of this study was to determine the effects of a one-minute chlorhexidine gluconate skin preparation protocol prior to cephalic vein catheterization. Twenty-three healthy beagle dogs had one leg aseptically prepared and the opposite leg served as a control. Twenty-six- and 77-hour time groups were studied. Chlorhexidine-treated legs had significantly lower cutaneous bacterial counts than the control legs prior to catheter insertion and prior to catheter withdrawal for both time groups. Control legs developed significantly more dermatitis than the treated legs after 77 h. A one-minute preparation with 4% chlorhexidine gluconate was an effective method for sustained reduction of cutaneous bacterial counts at peripheral intravenous catheter insertion points in dogs. Increased cutaneous bacterial counts were associated with significantly more microscopic dermatitis in untreated legs after 77 h of catheterization.
Beware Swan-Ganz complications. Perioperative management.
Asteri, T; Tsagaropoulou, I; Vasiliadis, K; Fessatidis, I; Papavasi-Liou, E; Spyrou, P
2002-08-01
Since the introduction of the pulmonary artery catheter (PAC) in 1970 by Swan et al., various complications are recognized with the insertion and the use of Swan-Ganz catheter. We present two different cases with rare but life threatening complications which had been successfully managed. The first case is a carotid cannulation with an 8.5 Fr introducer sheath, in an attempt to insert a pulmonary catheter via the right internal jugular vein. Two weeks later, the patient was re-admitted to the hospital and when an arteriovenous fistulae (carotid artery-internal jugular vein) was diagnosed, he was treated surgically. The second case presents the rupture of the right atrium in the conjunction with the superior vena cava. This serious cardiac complication was developed during the floatation of the PAC and the lesion was repaired while the mitral valve replacement was in progress.
Yousefshahi, Fardin; Azimpour, Khashayar; Boroumand, Mohammad Ali; Najafi, Mahdi; Barkhordari, Khosro; Vaezi, Mitra; Rouhipour, Nahid
2013-01-01
Background: Central venous (CV) catheters play an essential role in the management of critically ill patients in the Intensive Care Unit (ICU). CV lines are, however, allied to catheter-associated blood stream infections. Bacterial colonization of CV lines is deemed the main cause of catheter-associated infection. The purpose of our study was to compare bacterial colony counts in the catheter site before CV line insertion in two groups of post-cardiac surgery patients: a group receiving Sanosil (an antiseptic agent composed of H2O2 and silver) and a control group. Methods: This interventional prospective double-blinded clinical trial recruited the patients in three post-cardiac surgery ICUs of a heart center. The participants were divided into interventional (113 patients) and control (136 patients) groups. Sanosil was added to the routine preparation procedure (Chlorhexidine bath one day before and scrub with Povidone-Iodine just before the CV line insertion). After the removal of the CV lines, the catheters tips were sent for culture and evaluation of colony counts. Results: Catheter colonization occurred in 55 (22.1%) patients: 26 (23%) patients in the Sanosil group and 29 (21.3%) in the control group; there was no significant statistical difference between the two groups (p value = 0.75, RR = 1.05, 95% CI: 0.76–1.45). The most common organism having colonized in the cultures of the catheter tips was staphylococcus epidermis: 20 cases in the control group and 16 cases in the intervention group. Conclusion: Catheter colonization frequently occurs in post-cardiac surgery patients. However, our results did not indicate the effectiveness of adding Sanosil to the routine preparation procedure with respect to reducing catheter bacterial colonization. PMID:23967028
Yousefshahi, Fardin; Azimpour, Khashayar; Boroumand, Mohammad Ali; Najafi, Mahdi; Barkhordari, Khosro; Vaezi, Mitra; Rouhipour, Nahid
2013-04-01
Central venous (CV) catheters play an essential role in the management of critically ill patients in the Intensive Care Unit (ICU). CV lines are, however, allied to catheter-associated blood stream infections. Bacterial colonization of CV lines is deemed the main cause of catheter-associated infection. The purpose of our study was to compare bacterial colony counts in the catheter site before CV line insertion in two groups of post-cardiac surgery patients: a group receiving Sanosil (an antiseptic agent composed of H2O2 and silver) and a control group. This interventional prospective double-blinded clinical trial recruited the patients in three post-cardiac surgery ICUs of a heart center. The participants were divided into interventional (113 patients) and control (136 patients) groups. Sanosil was added to the routine preparation procedure (Chlorhexidine bath one day before and scrub with Povidone-Iodine just before the CV line insertion). After the removal of the CV lines, the catheters tips were sent for culture and evaluation of colony counts. Catheter colonization occurred in 55 (22.1%) patients: 26 (23%) patients in the Sanosil group and 29 (21.3%) in the control group; there was no significant statistical difference between the two groups (p value = 0.75, RR = 1.05, 95% CI: 0.76-1.45). The most common organism having colonized in the cultures of the catheter tips was staphylococcus epidermis: 20 cases in the control group and 16 cases in the intervention group. Catheter colonization frequently occurs in post-cardiac surgery patients. However, our results did not indicate the effectiveness of adding Sanosil to the routine preparation procedure with respect to reducing catheter bacterial colonization.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kroepil, Patric; Lanzman, Rotem S., E-mail: rotemshlomo@yahoo.de; Miese, Falk R.
2011-04-15
We report on percutaneous catheter procedures in the operating room (OR) to assist complicated manual extraction or insertion of pacemaker (PM) and implantable cardioverter defibrillator leads. We retrospectively reviewed complicated PM revisions and implantations performed between 2004 and 2009 that required percutaneous catheter procedures performed in the OR. The type of interventional procedure, catheter and retrieval system used, venous access, success rates, and procedural complications were analyzed. In 41 (12 female and 29 male [mean age 62 {+-} 17 years]) of 3021 (1.4%) patients, standard manual retrieval of old leads or insertion of new leads was not achievable and thusmore » required percutaneous catheter intervention for retrieval of misplaced leads and/or recanalisation of occluded central veins. Thirteen of 18 (72.2%) catheter-guided retrieval procedures for misplaced (right atrium [RA] or ventricle [RV; n = 3], superior vena cava [n = 2], brachiocephalic vein [n = 5], and subclavian vein [n = 3]) lead fragments in 16 patients were successful. Percutaneous catheter retrieval failed in five patients because there were extremely fixed or adhered lead fragments. Percutaneous transluminal angiography (PTA) of central veins for occlusion or high-grade stenosis was performed in 25 patients. In 22 of 25 patients (88%), recanalization of central veins was successful, thus enabling subsequent lead replacement. Major periprocedural complications were not observed. In the case of complicated manual PM lead implantation or revision, percutaneous catheter-guided extraction of misplaced lead fragments or recanalisation of central veins can be performed safely in the OR, thus enabling subsequent implantation or revision of PM systems in the majority of patients.« less
Hacker, Robert I.; Garcia, Lorena De Marco; Chawla, Ankur; Panetta, Thomas F.
2012-01-01
Fibrin sheaths are a heterogeneous matrix of cells and debris that form around catheters and are a known cause of central venous stenosis and catheter failure. A total of 50 cases of central venous catheter fibrin sheath angioplasty (FSA) after catheter removal or exchange are presented. A retrospective review of an outpatient office database identified 70 eligible patients over a 19-month period. After informed consent was obtained, the dialysis catheter exiting the skin was clamped, amputated, and a wire was inserted. The catheter was then removed and a 9-French sheath was inserted into the superior vena cava, a venogram was performed. If a fibrin sheath was present, angioplasty was performed using an 8 × 4 or 10 × 4 balloon along the entire length of the fibrin sheath. A completion venogram was performed to document obliteration of the sheath. During the study, 50 patients were diagnosed with a fibrin sheath, and 43 had no pre-existing central venous stenosis. After FSA, 39 of the 43 patient's (91%) central systems remained patent without the need for subsequent interventions; 3 patients (7%) developed subclavian stenoses requiring repeat angioplasty and stenting; 1 patent (2.3%) developed an occlusion requiring a reintervention. Seven patients with prior central stenosis required multiple angioplasties; five required stenting of their central lesions. Every patient had follow-up fistulograms to document long-term patency. We propose that FSA is a prudent and safe procedure that may help reduce the risk of central venous stenosis from fibrin sheaths due to central venous catheters. PMID:23997555
Johnson, Thomas J; Jamous, Fady G; Kooistra, Alma; Zawada, Edward T
2010-02-01
Extravasation of total parenteral nutrition (TPN) delivered via central lines is a known potential complication, but significant extravasations of infusate into the pleural space when using peripherally inserted central catheters (PICCs) have not been reported in adults. We report 2 cases ofpleural cavity extravasation ofTPN delivered via a PICC. Measurement of the glucose level of the effusate is a quick way to determine the presence of TPN and should be considered in any patient receiving TPN via any type of central line with a rapidly developing effusion.
Use of Electronic Tablets for Patient Education on Flushing Peripherally Inserted Central Catheters.
Petroulias, Patricia L
The purpose of this study was to examine the efficacy of using an electronic tablet to provide patient education for flushing peripherally inserted central catheters (PICCs) as a way to reduce the incidence of occlusion. Eleven patients, newly diagnosed with cancer, participated in a pilot study that used a video on PICC flushing and remote coaching using FaceTime (Apple, Cupertino, CA) to teach patients how to maintain their PICCs in their homes. At the end of the 6-week intervention, no adverse outcomes (occlusions or infections) were noted among the patients who participated in the study.
Venous Access Ports: Indications, Implantation Technique, Follow-Up, and Complications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walser, Eric M., E-mail: walser.eric@mayo.edu
The subcutaneous venous access device (SVAD or 'port') is a critical component in the care of patients with chronic disease. The modern SVAD provides reliable access for blood withdrawal and medication administration with minimal disruption to a patient's lifestyle. Because of improved materials and catheter technology, today's ports are lighter and stronger and capable of high-pressure injections of contrast for cross-sectional imaging. The majority of SVAD placement occurs in interventional radiology departments due to their ability to provide this service at lower costs, lower, complication rates, and greater volumes. Port-insertion techniques vary depending on the operator, but all consist ofmore » catheter placement in the central venous circulation followed by subcutaneous pocket creation and port attachment to the catheter with fixation and closure of the pocket. Venous access challenges occasionally occur in patients with central vein occlusions, necessitating catheterization of collateral veins or port placement in alternate locations. Complications of SVADs include those associated with the procedure as well as short- (<30 days) and long-term problems. Procedural and early complications are quite rare due to the near-universal use of real-time ultrasound guidance for vein puncture, but they can include hematoma, catheter malposition, arrhythmias, and pneumothorax. Late problems include both thrombotic complications (native venous or port-catheter thrombosis) and infections (tunnel or pocket infections or catheter-associated bloodstream infections). Most guidelines suggest that 0.3 infections/1000 catheter days is an appropriate upper threshold for the insertion of SVADs.« less
Dosimetric equivalence of nonstandard HDR brachytherapy catheter patterns
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cunha, J. A. M.; Hsu, I-C.; Pouliot, J.
2009-01-15
Purpose: To determine whether alternative high dose rate prostate brachytherapy catheter patterns can result in similar or improved dose distributions while providing better access and reducing trauma. Materials and Methods: Standard prostate cancer high dose rate brachytherapy uses a regular grid of parallel needle positions to guide the catheter insertion. This geometry does not easily allow the physician to avoid piercing the critical structures near the penile bulb nor does it provide position flexibility in the case of pubic arch interference. This study used CT datasets with 3 mm slice spacing from ten previously treated patients and digitized new cathetersmore » following three hypothetical catheter patterns: conical, bi-conical, and fireworks. The conical patterns were used to accommodate a robotic delivery using a single entry point. The bi-conical and fireworks patterns were specifically designed to avoid the critical structures near the penile bulb. For each catheter distribution, a plan was optimized with the inverse planning algorithm, IPSA, and compared with the plan used for treatment. Irrelevant of catheter geometry, a plan must fulfill the RTOG-0321 dose criteria for target dose coverage (V{sub 100}{sup Prostate}>90%) and organ-at-risk dose sparing (V{sub 75}{sup Bladder}<1 cc, V{sub 75}{sup Rectum}<1 cc, V{sub 125}{sup Urethra}<<1 cc). Results: The three nonstandard catheter patterns used 16 nonparallel, straight divergent catheters, with entry points in the perineum. Thirty plans from ten patients with prostate sizes ranging from 26 to 89 cc were optimized. All nonstandard patterns fulfilled the RTOG criteria when the clinical plan did. In some cases, the dose distribution was improved by better sparing the organs-at-risk. Conclusion: Alternative catheter patterns can provide the physician with additional ways to treat patients previously considered unsuited for brachytherapy treatment (pubic arch interference) and facilitate robotic guidance of catheter insertion. In addition, alternative catheter patterns may decrease toxicity by avoidance of the critical structures near the penile bulb while still fulfilling the RTOG criteria.« less
Ureteric catheterization via an ileal conduit: technique and retrieval of a JJ stent.
Wah, T M; Kellett, M J
2004-11-01
Retrograde ureteric catheterization of a patient with an ileal conduit is difficult, because guide wires and catheters coil in the conduit. A modified loopogram, using a Foley catheter as a fulcrum through which catheters can be advanced to the ureteric anastomosis, is described. This technique was used to remove a JJ stent, which had been inserted previously across a stricture in one ureter, the stent crossing from one kidney to the other.
Balaminut, Talita; Venturini, Danielle; da Silva, Valéria Costa Evangelista; Rossetto, Edilaine Giovanini; Zani, Adriana Valongo
2015-01-01
Objective: To compare the efficacy of two concentrations of heparin to clear the lumen of in vitro clotted neonatal peripherally inserted central catheters (PICCs). Methods: This is an in vitro, experimental quantitative study of 76 neonatal 2.0-Fr PICCs coagulated in vitro. The catheters were divided into two groups of 38 PICCs each. In both groups an infusion of low molecular weight heparin was administered with a dose of 25IU/mL for Group 1 and 50IU/mL for Group 2. The negative pressure technique was applied to the catheters of both groups at 5, 15 and 30min and at 4h to test their permeability. Kaplan-Meier survival analysis was used to verify the outcome of the groups according to time intervals. Results: The comparison between both groups in the first 5min showed that more catheters from Group 2 were cleared compared to Group 1 (57.9 vs. 21.1%, respectively). Kaplan-Meier survival analysis showed that less time was needed to clear catheters treated with 50IU/mL of heparin (p<0.001). Conclusions: The use of low molecular weight heparin at a concentration of 50IU/mL was more effective in restoring the permeability of neonatal PICCs occluded in vitro by a clot, and the use of this concentration is within the safety margin indicated by scientific literature. PMID:26116325
Mariano, Edward R; Harrison, T Kyle; Kim, T Edward; Kan, Jack; Shum, Cynthia; Gaba, David M; Ganaway, Toni; Kou, Alex; Udani, Ankeet D; Howard, Steven K
2015-10-01
Practicing anesthesiologists have generally not received formal training in ultrasound-guided perineural catheter insertion. We designed this study to determine the efficacy of a standardized teaching program in this population. Anesthesiologists in practice for 10 years or more were recruited and enrolled to participate in a 1-day program: lectures and live-model ultrasound scanning (morning) and faculty-led iterative practice and mannequin-based simulation (afternoon). Participants were assessed and recorded while performing ultrasound-guided perineural catheter insertion at baseline, at midday (interval), and after the program (final). Videos were scored by 2 blinded reviewers using a composite tool and global rating scale. Participants were surveyed every 3 months for 1 year to report the number of procedures, efficacy of teaching methods, and implementation obstacles. Thirty-two participants were enrolled and completed the program; 31 of 32 (97%) completed the 1-year follow-up. Final scores [median (10th-90th percentiles)] were 21.5 (14.5-28.0) of 30 points compared to 14.0 (9.0-20.0) at interval (P < .001 versus final) and 12.0 (8.5-17.5) at baseline (P < .001 versus final), with no difference between interval and baseline. The global rating scale showed an identical pattern. Twelve of 26 participants without previous experience performed at least 1 perineural catheter insertion after training (P < .001). However, there were no differences in the monthly average number of procedures or complications after the course when compared to baseline. Practicing anesthesiologists without previous training in ultrasound-guided regional anesthesia can acquire perineural catheter insertion skills after a 1-day standardized course, but changing clinical practice remains a challenge. © 2015 by the American Institute of Ultrasound in Medicine.
Central venous catheters: legal issues.
Gallieni, Maurizio; Martina, Valentina; Rizzo, Maria Antonietta; Gravellone, Luciana; Mobilia, Francesca; Giordano, Antonino; Cusi, Daniele; Genovese, Umberto
2011-01-01
In dialysis patients, both central venous catheter (CVC) insertion and CVC use during the dialysis procedure pose important legal issues, because of potentially severe, even fatal, complications. The first issue is the decision of the kind of vascular access that should be proposed to patients: an arteriovenous (AV) fistula, a graft, or a CVC. The second issue, when choosing the CVC option, is the choice of CVC: nontunneled versus tunneled. Leaving a temporary nontunneled CVC for a prolonged time increases the risk of complications and could raise a liability issue. Even when choosing a long-term tunneled CVC, nephrologists should systematically explain its potential harms, presenting them as "unsafe for long-term use" unless there is a clear contraindication to an AV native or prosthetic access. Another critical issue is the preparation of a complete, informative, and easy-to-understand consent form. The CVC insertion procedure has many aspects of legal interest, including the choice of CVC, the use of ECG monitoring, the use of ultrasound guidance for cannulation, and the use of fluoroscopy for checking the position of the metal guidewire during the procedure as well as the CVC tip before the end of the procedure. Use of insertion devices and techniques that can prevent complications should obviously be encouraged. Complications of CVC use are mainly thrombosis and infection. These are theoretically expected as pure complications (and not as malpractice effects), but legal issues might relate to inappropriate catheter care (in both the inpatient and outpatient settings) rather than to the event per se. Thus, in the individual case it is indeed very difficult to establish malpractice and liability with a catheter-related infection or thrombosis. In conclusion, we cannot avoid complications completely when using CVCs, but reducing them to a minimum and adopting safe approaches to their insertion and use will reduce legal liability.
Effects of Bovine Polymerized Hemoglobin in Coagulation in Controlled Hemorrhagic Shock in Swine
2005-01-01
continuous blood pressure monitoring. A pulmonary artery catheter was also inserted. To mimic soft tissue injury, the rectus abdominus muscle was crushed in...volume by catheter withdrawal of blood over 15 min (;1.7 mL/kg/min). Time 0 designated initiation of the rectus abdominus crush and concomitant hemorrhage
Development of Bend Sensor for Catheter Tip
NASA Astrophysics Data System (ADS)
Nagano, Yoshitaka; Sano, Akihito; Fujimoto, Hideo
Recently, a minimally invasive surgery which makes the best use of the catheter has been becoming more popular. In endovascular coil embolization for a cerebral aneurysm, the observation of the catheter's painting phenomenon is very important to execute the appropriate manipulation of the delivery wire and the catheter. In this study, the internal bend sensor which consists of at least two bending enhanced plastic optical fibers was developed in order to measure the curvature of the catheter tip. Consequently, the painting could be more sensitively detected in the neighborhood of the aneurysm. In this paper, the basic characteristics of the developed sensor system are described and its usefulness is confirmed from the comparison of the insertion force of delivery wire and the curvature of catheter tip in the experiment of coil embolization.
Lobo, Bob L; Vaidean, Georgeta; Broyles, Joyce; Reaves, Anne B; Shorr, Ronald I
2009-09-01
Peripherally inserted central catheters (PICC) are increasingly used in hospitalized patients. The benefit can be offset by complications such as upper extremity deep vein thrombosis (UEDVT). Retrospective study of patients who received a PICC while hospitalized at the Methodist University Hospital (MUH) in Memphis, TN. All adult consecutive patients who had PICCs inserted during the study period and who did not have a UEDVT at the time of PICC insertion were included in the study. A UEDVT was defined as a symptomatic event in the ipsilateral extremity, leading to the performance of duplex ultrasonography, which confirmed the diagnosis of UEDVT. Pulmonary embolism (PE) was defined as a symptomatic event prompting the performance of ventilation-perfusion lung scan or spiral computed tomography (CT). Among 777 patients, 38 patients experienced 1 or more venous thromboembolisms (VTEs), yielding an incidence of 4.89%. A total of 7444 PICC-days were recorded for 777 patients. This yields a rate of 5.10 VTEs/1000 PICC-days. Compared to patients whose PICC was inserted in the SVC, patients whose PICC was in another location had an increased risk (odds ratio = 2.61 [95% CI = 1.28-5.35]) of VTE. PICC related VTE was significantly more common among patients with a past history of VTE (odds ratio = 10.83 [95% CI = 4.89-23.95]). About 5% of patients undergoing PICC placement in acute care hospitals will develop thromboembolic complications. Thromboembolic complications were especially common among persons with a past history of VTE. Catheter tip location at the time of insertion may be an important modifiable risk factor. Copyright 2009 Society of Hospital Medicine.
Operational Definitions of Labor and Delivery Nursing Activities.
1987-07-01
assess and record fetal heart rate. (S 2406 r) ZO!3 FETAL ELECTRODE INSERTION (RN): position patient, insert fetal electrode, secure monitor leads...to leg plate to patient’s lower extremity, connect, assess and record fetal heart rate. (S2405r) Z014 FETAL ELECTRODE INSERTION/INTRAUTERINE CATHETER...INSERTION, ASSIST: position patient for procedure, secure monitor Teads to patient’s lower extremity, assess and record fetal heart tones. Set up
Pérez-Granda, María Jesús; Guembe, María; Cruces, Raquel; Barrio, José María; Bouza, Emilio
2016-02-02
Culture of catheter hubs and skin surrounding the catheter entry site has a negative predictive value for catheter tip colonization. However, manipulation of the hub for culture requires the hubs to be swabbed, introducing potential dislodging of biofilm and subsequent migration of microorganisms. Hubs are usually closed with needleless connectors (NCs), which are replaced regularly. Our objective was to evaluate whether culture of flushed withdrawn NCs is an alternative to hub culture when investigating central venous catheter colonization. The study population comprised 49 intensive care unit patients whose central venous catheters had been in place for at least 7 days. Cultures of NCs and skin were obtained weekly. We included 82 catheters with more than 7 days' indwelling time. The catheter tip colonization rate was 18.3% (15/82). Analysis of skin and NC cultures revealed a 92.5% negative predictive value for catheter colonization. Three episodes of catheter-related bloodstream infection (C-RBSI) occurred in patients with colonized catheters. Surveillance of NC and skin cultures could help to identify patients at risk for C-RBSI.
Thrombotic complications of central venous catheters in cancer patients.
Kuter, David J
2004-01-01
Central venous catheters (CVCs), such as the tunneled catheters and the totally implanted ports, play a major role in general medicine and oncology. Aside from the complications (pneumothorax, hemorrhage) associated with their initial insertion, all of these CVCs are associated with the long-term risks of infection and thrombosis. Despite routine flushing with heparin or saline, 41% of CVCs result in thrombosis of the blood vessel, and this markedly increases the risk of infection. Only one-third of these clots are symptomatic. Within days of insertion, almost all CVCs are coated with a fibrin sheath, and within 30 days, most CVC-related thrombi arise. Aside from reducing the function of the catheter, these CVC-related thrombi can cause postphlebitic syndrome in 15%-30% of cases and pulmonary embolism in 11% (only half of which are symptomatic). Risk factors for CVC thrombosis include the type of malignancy, type of chemotherapy, type of CVC, and locations of insertion site and catheter tip, but not inherited thrombophilic risk factors. Efforts to reduce CVC thrombosis with systemic prophylactic anticoagulation with low-molecular-weight heparin have failed. Low-dose warfarin prophylaxis remains controversial; all studies are flawed, with older studies, but not newer ones, showing benefit. Currently, less than 10% of patients with CVCs receive any systemic prophylaxis. Although its general use cannot be recommended, low-dose warfarin may be a low-risk treatment in patients with good nutrition and adequate hepatic function. Clearly, additional studies are required to substantiate the prophylactic use of low-dose warfarin. Newer anticoagulant treatments, such as pentasaccharide and direct thrombin inhibitors, need to be explored to address this major medical problem.
Meddings, Jennifer; Rogers, Mary A M; Krein, Sarah L; Fakih, Mohamad G; Olmsted, Russell N; Saint, Sanjay
2014-01-01
Background Catheter-associated urinary tract infections (CAUTI) are costly, common and often preventable by reducing unnecessary urinary catheter (UC) use. Methods To summarise interventions to reduce UC use and CAUTIs, we updated a prior systematic review (through October 2012), and a meta-analysis regarding interventions prompting UC removal by reminders or stop orders. A narrative review summarises other CAUTI prevention strategies including aseptic insertion, catheter maintenance, antimicrobial UCs, and bladder bundle implementation. Results 30 studies were identified and summarised with interventions to prompt removal of UCs, with potential for inclusion in the meta-analyses. By meta-analysis (11 studies), the rate of CAUTI (episodes per 1000 catheter-days) was reduced by 53% (rate ratio 0.47; 95% CI 0.30 to 0.64, p<0.001) using a reminder or stop order, with five studies also including interventions to decrease initial UC placement. The pooled (nine studies) standardised mean difference (SMD) in catheterisation duration (days) was −1.06 overall (p=0.065) including a statistically significant decrease in stop-order studies (SMD −0.37; p<0.001) but not in reminder studies (SMD, −1.54; p=0.071). No significant harm from catheter removal strategies is supported. Limited research is available regarding the impact of UC insertion and maintenance technique. A recent randomised controlled trial indicates antimicrobial catheters provide no significant benefit in preventing symptomatic CAUTIs. Conclusions UC reminders and stop orders appear to reduce CAUTI rates and should be used to improve patient safety. Several evidence-based guidelines have evaluated CAUTI preventive strategies as well as emerging evidence regarding intervention bundles. Implementation strategies are important because reducing UC use involves changing well-established habits. PMID:24077850
Mestre Roca, Gabriel; Berbel Bertolo, Cristina; Tortajada Lopez, Purificación; Gallemi Samaranch, Gema; Aguilar Ramirez, Mari Carmen; Caylà Buqueras, Joan; Rodríguez-Baño, Jesús; Martinez, José Antonio
2012-07-21
To assess the influence of risk factors on the rates and kinetics of peripheral vein phlebitis (PVP) development and its theoretical influence in absolute PVP reduction after catheter replacement. All peripheral short intravenous catheters inserted during one month were included (1201 catheters and 967 patients). PVP risk factors were assessed by a Cox proportional hazard model. Cumulative probability, conditional failure of PVP and theoretical estimation of the benefit from replacement at different intervals were performed. Female gender, catheter insertion at the emergency or medical-surgical wards, forearm site, amoxicillin-clavulamate or aminoglycosides were independent predictors of PVP with hazard ratios (95 confidence interval) of 1.46 (1.09-2.15), 1.94 (1.01-3.73), 2.51 (1.29-4.88), 1.93 (1.20-3.01), 2.15 (1.45-3.20) and 2.10 (1.01-4.63), respectively. Maximum phlebitis incidence was reached sooner in patients with ≥2 risk factors (days 3-4) than in those with <2 (days 4-5). Conditional failure increased from 0.08 phlebitis/one catheter-day for devices with ≤1 risk factors to 0.26 for those with ≥3. The greatest benefit of routine catheter exchange was obtained by replacement every 60h. However, this benefit differed according to the number of risk factors: 24.8% reduction with ≥3, 13.1% with 2, and 9.2% with ≤1. PVP dynamics is highly influenced by identifiable risk factors which may be used to refine the strategy of catheter management. Routine replacement every 72h seems to be strictly necessary only in high-risk catheters. Copyright © 2011 Elsevier España, S.L. All rights reserved.
Helder, Onno; Kornelisse, René; van der Starre, Cynthia; Tibboel, Dick; Looman, Caspar; Wijnen, René; Poley, Marten; Ista, Erwin
2013-10-14
Central venous catheter-associated bloodstream infections in children are an increasingly recognized serious safety problem worldwide, but are often preventable. Central venous catheter bundles have proved effective to prevent such infections. Successful implementation requires changes in the hospital system as well as in healthcare professionals' behaviour. The aim of the study is to evaluate process and outcome of implementation of a state-of-the-art central venous catheter insertion and maintenance bundle in a large university children's hospital. An interrupted time series design will be used; the study will encompass all children who need a central venous catheter. New state-of-the-art central venous catheter bundles will be developed. The Pronovost-model will guide the implementation process. We developed a tailored multifaceted implementation strategy consisting of reminders, feedback, management support, local opinion leaders, and education. Primary outcome measure is the number of catheter-associated infections per 1000 line-days. The process outcome is degree of adherence to use of these central venous catheter bundles is the secondary outcome. A cost-effectiveness analysis is part of the study. Outcomes will be monitored during three periods: baseline, pre-intervention, and post-intervention for over 48 months. This model-based implementation strategy will reveal the challenges of implementing a hospital-wide safety program. This work will add to the body of knowledge in the field of implementation. We postulate that healthcare workers' willingness to shift from providing habitual care to state-of-the-art care may reflect the need for consistent care improvement. Trial registration: Dutch trials registry, trial # 3635. Dutch trials registry (http://www.trialregister.nl), trial # 3635.
1991-01-01
central venous catheter is inserted into the bloodstream, a fibrin sheath forms around the cannula which attracts bacteria . Bacteria can either migrate from...to the fibrin sheath. After colonization of the fibrin sheath, the bacteria replicate and are released into the bloodstream when symptoms may develop...culture." Rose et al. (1988, p. 511) defined catheter site infection as occurring when "cultures at the exit site are identical to bacteria found on
Frykholm, P; Pikwer, A; Hammarskjöld, F; Larsson, A T; Lindgren, S; Lindwall, R; Taxbro, K; Oberg, F; Acosta, S; Akeson, J
2014-05-01
Safe and reliable venous access is mandatory in modern health care, but central venous catheters (CVCs) are associated with significant morbidity and mortality, This paper describes current Swedish guidelines for clinical management of CVCs The guidelines supply updated recommendations that may be useful in other countries as well. Literature retrieval in the Cochrane and Pubmed databases, of papers written in English or Swedish and pertaining to CVC management, was done by members of a task force of the Swedish Society of Anaesthesiology and Intensive Care Medicine. Consensus meetings were held throughout the review process to allow all parts of the guidelines to be embraced by all contributors. All of the content was carefully scored according to criteria by the Oxford Centre for Evidence-Based Medicine. We aimed at producing useful and reliable guidelines on bleeding diathesis, vascular approach, ultrasonic guidance, catheter tip positioning, prevention and management of associated trauma and infection, and specific training and follow-up. A structured patient history focused on bleeding should be taken prior to insertion of a CVCs. The right internal jugular vein should primarily be chosen for insertion of a wide-bore CVC. Catheter tip positioning in the right atrium or lower third of the superior caval vein should be verified for long-term use. Ultrasonic guidance should be used for catheterisation by the internal jugular or femoral veins and may also be used for insertion via the subclavian veins or the veins of the upper limb. The operator inserting a CVC should wear cap, mask, and sterile gown and gloves. For long-term intravenous access, tunnelled CVC or subcutaneous venous ports are preferred. Intravenous position of the catheter tip should be verified by clinical or radiological methods after insertion and before each use. Simulator-assisted training of CVC insertion should precede bedside training in patients. Units inserting and managing CVC should have quality assertion programmes for implementation and follow-up of routines, teaching, training and clinical outcome. Clinical guidelines on a wide range of relevant topics have been introduced, based on extensive literature retrieval, to facilitate effective and safe management of CVCs. © 2014 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Management of complications related to central venous catheters in cancer patients: an update.
Linnemann, Birgit
2014-04-01
Central venous catheters (CVCs) are important for the treatment of patients with cancer, especially in the perioperative and palliative care settings. These devices not only allow for the administration of chemotherapy, parenteral nutrition, and other intravenous therapies, but they may also improve the patients' quality of life by reducing the need for repeated peripheral venipunctures. Thrombotic and infectious complications are common, especially in the long-term use of CVCs. There are different types of thrombotic complications associated with CVCs, that is, a thrombotic occlusion of the catheter, a mural thrombus at the catheter tip and classical deep vein thrombosis, which occurs most frequently in the upper extremity where the majority of long-term catheters are inserted. Infections are common complications associated with CVCs. Patients with cancer who receive intensive chemotherapy and those patients who undergo hematopoietic stem cell transplantation have a markedly increased risk for insertion site and bloodstream infections. In this review, the epidemiology and risk factors that predispose patients to CVC-related thrombosis and infection are discussed. The diagnostic and therapeutic options according to the published data and the current guidelines are summarized and data for establishing primary and secondary preventative strategies are provided. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Choi, Sun Young; Kim, Ah Hyun; Kim, Kyung Ah; Won, Jong Yun; Lee, Do Yun; Lee, Kwang-Hun
2010-01-01
We assessed the outcomes of a simplified technique for the percutaneous placement of a hepatic artery port-catheter system for chemotherapy infusion in advanced hepatocellular carcinoma with portal vein invasion. From February 2003 to February 2008, percutaneous hepatic artery port-catheter insertion was performed in 122 patients who had hepatocellular carcinoma with portal vein invasion. The arterial access route was the common femoral artery. The tip of the catheter was wedged into the right gastroepiploic artery without an additional fixation device. A side hole was positioned at the distal common hepatic artery to allow the delivery of chemotherapeutic agents into the hepatic arteries. Coil embolization was performed only to redistribute to the hepatic arteries or to prevent the inadvertent delivery of chemotherapeutic agents into extrahepatic arteries. The port chamber was created at either the supra-inguinal or infra-inguinal region. Technical success was achieved in all patients. Proper positioning of the side hole was checked before each scheduled chemotherapy session by port angiography. Catheter-related complications occurred in 19 patients (16%). Revision was achieved in 15 of 18 patients (83%). This simplified method demonstrates excellent technical feasibility, an acceptable range of complications, and is hence recommended for the management of advanced hepatocellular carcinoma with portal vein thrombosis.
Teragawa, Hiroki; Sueda, Takashi; Fujii, Yuichi; Takemoto, Hiroaki; Toyota, Yasushi; Nomura, Shuichi; Nakagawa, Keigo
2013-01-01
We report a successful endovascular technique using a snare with a suture for retrieving a migrated broken peripherally inserted central catheter (PICC) in a chemotherapy patient. A 62-year-old male received monthly chemotherapy through a central venous port implanted into his right subclavian area. The patient completed chemotherapy without complications 1 mo ago; however, he experienced pain in the right subclavian area during his last chemotherapy session. Computed tomography on that day showed migration of a broken PICC in his left pulmonary artery, for which the patient was admitted to our hospital. We attempted to retrieve the ectopic PICC through the right jugular vein using a gooseneck snare, but were unsuccessful because the catheter was lodged in the pulmonary artery wall. Therefore, a second attempt was made through the right femoral vein using a snare with triple loops, but we could not grasp the migrated PICC. Finally, a string was tied to the top of the snare, allowing us to curve the snare toward the pulmonary artery by pulling the string. Finally, the catheter body was grasped and retrieved. The endovascular suture technique is occasionally extremely useful and should be considered by interventional cardiologists for retrieving migrated catheters. PMID:24109502
Meyer, Britt M
The purpose of this interpretive phenomenological study was to determine what it means to patients to live with a peripherally inserted central catheter (PICC)-related deep vein thrombosis and to describe the influence of the experience on the individual's quality of life. The sample included 11 adult patients from an acute care setting who developed a PICC-related symptomatic thrombus between November 2014 and March 2016, using purposive sampling. Three distinct themes emerged from the data in this study: a loss of trust in health care providers, additional burdens to existing problems, and a yearning for understanding.
Bergmann, Lars
2018-06-01
This guideline was presented in 2016 due to the need for an up to date evidence-based guidance focusing on patient safety. In addition to safety-related aspects of catheter insertion or removal, organisational issues and structured training concepts were discussed. The guideline was created based on the review of current literature as well as expert opinion. The article summarizes and discusses the most important recommendations and the reader is provided with practical advice for catheter insertion or removal with the intention to improve the safety of the patients. Georg Thieme Verlag KG Stuttgart · New York.
Risk of Infection Using Peripherally Inserted Central and Umbilical Catheters in Preterm Neonates.
Shalabi, Mohamed; Adel, Mohamed; Yoon, Eugene; Aziz, Khalid; Lee, Shoo; Shah, Prakesh S
2015-12-01
To compare the rates of catheter-associated bloodstream infection (CABSI) in preterm infants born at <30 weeks' gestation who received a peripherally inserted central catheter (PICC) versus an umbilical venous catheter (UVC) immediately after birth as their primary venous access. This retrospective matched cohort study examined data from infants born at <30 weeks' gestation and admitted between January 2010 and December 2013 to neonatal units in the Canadian Neonatal Network. Eligible infants who received a PICC on the first day after birth (day 1) were matched with 2 additional groups of infants, those who received a UVC on day 1 and those who received a UVC on day 1 that was then changed for a PICC after 4 days or more. The primary outcome was number of infants with CABSI per 1000 catheter days, which was compared between the 3 groups using multivariable analyses. Data from 540 eligible infants were reviewed (180 per group). There was no significant difference in infants with CABSI/1000 catheter days between the 3 groups (9.3 vs 7.8 vs 8.2/1000 catheter days, respectively; P > .05) despite lower rates of late onset sepsis in the group of infants who received only a UVC. There was no significant difference in the incidence of CABSI between very preterm neonates who received a PICC, UVC, or UVC followed by PICC as the primary mode of venous access after birth. A prospective randomized controlled trial is justified to further guide practice regarding primary venous access and reduction of infection. Copyright © 2015 by the American Academy of Pediatrics.
Bıçakcı, Ünal; Genç, Gürkan; Tander, Burak; Günaydın, Mithat; Demirel, Dilek; Özkaya, Ozan; Rızalar, Rıza; Arıtürk, Ender; Bernay, Ferit
2016-01-01
INTRODUCTION: The aim of this study was to evaluate patients with end stage renal failure (ESRD) who underwent chronic peritoneal dialysis (CPD). The clinical outcomes of laparoscopic and open placements of catheters were compared. MATERIALS AND METHODS: We reviewed 49 (18 male and 31 female) children with CPD according to age, sex, cause of ESRD, catheter insertion method, kt/V rate, complications, presence of peritonitis, catheter survival rate between January 2002 and February 2014. RESULTS: Thirty-three patients were with open placement and 16 patients were with laparoscopic placement. The rate of the peritonitis is significantly less in patients with laparoscopic access than open access (n = 4 vs n = 25) (P <0.01). Patients with peritonitis were younger than those who had no attack of peritonitis (10.95 ± 0.8 years vs 13.4 ± 0.85 years). According to the development of complications, significant difference has not been found between the open (n = 9) and laparoscopic (n = 3) approaches except the peritonitis. Catheter survival rate for the first year was 95%, and for five years was 87.5%. There was no difference between open and laparoscopic group according to catheter survival rate. The mean kt/V which indicates the effectiveness of peritoneal dialysis was mean 2.26 ± 0.08. No difference was found between laparoscopic and open methods according to kt/V. CONCLUSION: Laparoscopic placement of CPD results in lower peritonitis rate. Catheter survival rate was excellent in both groups. Single port laparoscopic access for CPD catheter insertion is an effective and safe method. PMID:27073310
Harris, Benjamin D; Nilsson, Sanna; Poole, Christopher M
2015-09-01
This feasibility study aims to determine if a low-cost 3D printer (BitsFromBytes 3D Touch) with ABS plastic can print custom mould structures and catheter channels defined in a brachytherapy treatment planning system (Nucletron Oncentra) for patient-specific treatment. Printer accuracy was evaluated through physical measurement, and print quality was investigated by adjusting print parameters (print speed, layer thickness, percentage infill). Catheter positioning and reproducibility were measured over repeated insertions. ABS plastic water equivalency was investigated by comparing Ir-192 HDR source dose distributions, measured with radiochromic film, in ABS plastic and in water. Structures and catheter channels were printed accurately to within 0.5 mm laterally and 1 mm in the vertical print direction. Adjusting print parameters could reduce print time, albeit with reduced print quality. 3.5 mm channel diameters allowed for easy catheter insertion. Catheter positioning was reproducible to within 0.5 mm but, because of catheter flex within the channel, was on average 1 mm offset from defined TPS positions. This offset could be accounted for by repeating the treatment planning CT scan with the printed mould positioned on the patient. Dose attenuation in ABS plastic and in water was equivalent to within the measurement limitations. While clinical uses for this particular low-cost printer and ABS plastic are limited by print size restrictions and non-certification for biocompatibility, it has been demonstrated that a low-cost 3D printer set-up can accurately create custom moulds and catheter channels potentially acceptable for clinical use.
Abdelaal Ahmed Mahmoud, Ahmed; El-Shafei, Hassan Ismail; Yassin, Hany Mahmoud; Elramely, Mohamed Adly; Abdelhaq, Mohamed Mohamed; El Kady, Hany Wafiq; Awada, Wael Nabil Fahemy
2017-06-01
Antegrade cannulation of peripheral veins is the usual practice. Blood stasis between a catheter and the wall of the vein or at its tip in addition to catheter-induced phlebitis may initiate a thrombosis. The use of retrograde ventriculojugular shunts against the direction of the blood flow with resultant decrease in the incidence of venous thrombosis encouraged us to compare retrograde versus conventional antegrade peripheral venous cannulation. Monocentric, nonblinded, prospective observational cohort of 40 intensive care unit patients receiving 2 peripheral venous catheters in upper limbs, 1 inserted in the direction of blood flow (antegrade cannula) and the other inserted in an opposite direction to blood flow (retrograde cannula). Daily ultrasound assessment of the angle between the catheter and the vascular wall was done to detect onset and progression of thrombus formation. The study included 40 patients, aged 46.7 ± 10.132 years. The incidence of thrombus formation was 100% in both techniques. The onset time of thrombus formation between the catheter and the wall of a vein was significantly longer with the retrograde catheters than with the antegrade catheters with median time (interquartile range [range]) 6 days (5-6.75 [4-8]) with 95% confidence interval (CI), 5.58-6.42 vs 3 days (3-4 [2-5]) with 95% CI (2.76-3.24), respectively, with a P value <.001. The time needed by the recently detected thrombus to reach the catheter tip determined by ultrasound with or without catheter failure was significantly longer in the retrograde catheters than in the antegrade catheter with median time (interquartile range [range]) 9 days (8-9 [7-10]) with 95% CI, 8.76-9.24 vs 4 days (4-5 [3-6]) with 95% CI, 3.76-4.24, respectively, with a P value <.001. Retrograde cannulation did not decrease the incidence of thrombus formation, but significantly increased the onset time until thrombus formation and prolonged the time needed by the newly formed thrombus to reach the catheter tip compared with conventional antegrade cannulation.
Advanced Imaging Catheter: Final Project Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krulevitch, P; Colston, B; DaSilva, L
2001-07-20
Minimally invasive surgery (MIS) is an approach whereby procedures conventionally performed with large and potentially traumatic incisions are replaced by several tiny incisions through which specialized instruments are inserted. Early MIS, often called laparoscopic surgery, used video cameras and laparoscopes to visualize and control the medical devices, which were typically cutting or stapling tools. More recently, catheter-based procedures have become a fast growing sector of all surgeries. In these procedures, small incisions are made into one of the main arteries (e.g. femoral artery in the thigh), and a long thin hollow tube is inserted and positioned near the target area.more » The key advantage of this technique is that recovery time can be reduced from months to a matter of days. In the United States, over 700,000 catheter procedures are performed annually representing a market of over $350 million. Further growth in this area will require significant improvements in the current catheter technology. In order to effectively navigate a catheter through the tortuous vessels of the body, two capabilities must exist: imaging and positioning. In most cases, catheter procedures rely on radiography for visualization and manual manipulation for positioning of the device. Radiography provides two-dimensional, global images of the vasculature and cannot be used continuously due to radiation exposure to both the patient and physician. Intravascular ultrasound devices are available for continuous local imaging at the catheter tip, but these devices cannot be used simultaneously with therapeutic devices. Catheters are highly compliant devices, and manipulating the catheter is similar to pushing on a string. Often, a guide wire is used to help position the catheter, but this procedure has its own set of problems. Three characteristics are used to describe catheter maneuverability: (1) pushability -- the amount of linear displacement of the distal end (inside body) relative to an applied displacement of the proximal end (outside body); (2) torquability -- the amount of rotation of the distal end relative to an applied rotation of the proximal end; and (3) trackability -- the extent to which the catheter tracks along the guide wire without displacing it.« less
Double Guiding Catheters for Complex Percutaneous Coronary Intervention
Chou, Shing-Hsien; Lin, Chia-Pin; Lin, Yen-Chen; Kuo, Chi-Tai; Lin, Ming-Shyan; Chang, Chi-Jen
2012-01-01
A large-lumen guiding catheter is often used for complex percutaneous coronary intervention—particularly when a final kissing-balloon or 2-stent technique is required. However, catheter insertion is sometimes restricted by diseased vascular access sites or a tortuous vascular route. We report 2 cases in which a unique double guiding catheter technique was used to create a lumen of sufficient size for complex percutaneous coronary intervention. In each patient, two 6F guiding catheters were used concurrently to engage the ostium of 1 target vessel. In 1 patient, these catheters were used for the delivery of 2 balloons to complete kissing-balloon dilation after single-stent placement. In the other patient, the catheters were used to deliver 2 stents sequentially to their respective target lesions. The stents were then deployed simultaneously as kissing stents, followed by high-pressure kissing-balloon postdilation. PMID:22412243
van de Wetering, Marianne D; van Woensel, Job B M; Lawrie, Theresa A
2013-11-25
This is an updated version of the review which was first published in the Cochrane Database of Systematic Reviews in 2006. Long-term central venous catheters (CVCs), including tunnelled CVCs (TCVCs) and totally implanted devices or ports (TIDs), are increasingly used when treating oncology patients. Despite international guidelines on sterile insertion and appropriate CVC maintenance and use, infection remains a common complication. These infections are mainly caused by Gram positive bacteria. Antimicrobial prevention strategies aimed at these micro-organisms could potentially decrease the majority of CVC infections. The aim of this review was to evaluate the efficacy of antibiotics in the prevention of Gram positive infections in long-term CVCs. To determine the efficacy of administering antibiotics prior to the insertion of long-term CVCs, or flushing or locking long-term CVCs with a combined antibiotic and heparin solution, or both, to prevent Gram positive catheter-related infections in adults and children receiving treatment for cancer. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (to June 2013) and the MEDLINE and EMBASE databases (1966 to 2013). Randomised controlled trials (RCTs) comparing prophylactic antibiotics given prior to long-term CVC insertion with no antibiotics, RCTs comparing a combined antibiotic and heparin solution with a heparin-only solution to flush or lock newly inserted long-term CVCs, and RCTs comparing a combination of these interventions in adults and children receiving treatment for cancer. Two authors independently selected studies, classified them and extracted data on to a pre-designed data collection form. We pooled data using the RevMan software version 5.2 and used random-effects (RE) model methods for meta-analyses. We included 11 trials with a total of 828 oncology patients (adults and children). We assessed most included studies to be at a low or unclear risk of bias. Five trials compared the use of antibiotics (vancomycin, teicoplanin or ceftazidime) given before the insertion of the long-term CVC with no antibiotics, and six trials compared antibiotics (vancomycin, amikacin or taurolidine) and heparin with a heparin-only solution for flushing or locking the long-term CVC after use. Administering an antibiotic prior to insertion of the CVC did not significantly reduce Gram positive catheter-related sepsis (CRS) (five trials, 360 adults; risk ratio (RR) 0.72, 95% confidence interval (CI) 0.33 to 1.58; I² = 5 2%; P = 0.41).Flushing and locking long-term CVCs with a combined antibiotic and heparin solution significantly reduced the risk of Gram positive catheter-related sepsis compared with a heparin-only solution (468 participants, mostly children; RR 0.47, 95% CI 0.28 to 0.80; I² = 0%; P = 0.005). For a baseline infection rate of 15%, this reduction translated into a number needed to treat (NNT) of 12 (95% CI 9 to 33) to prevent one catheter-related infection. We considered this evidence to be of a moderate quality. There was no benefit to administering antibiotics before the insertion of long-term CVCs to prevent Gram positive catheter-related infections. Flushing or locking long-term CVCs with a combined antibiotic and heparin solution appeared to reduce Gram positive catheter-related sepsis experienced in people at risk of neutropenia through chemotherapy or disease. Due to insufficient data it was not clear whether this applied equally to TCVCs and totally implanted devices (TIDs), or equally to adults and children. The use of a combined antibiotic and heparin solution may increase microbial antibiotic resistance, therefore it should be reserved for high risk people or where baseline CVC infection rates are high (> 15%). Further research is needed to identify high risk groups most likely to benefit.
CT-Guided Placement of a Drainage Catheter Within a Pelvic Abscess Using a Transsacral Approach
DOE Office of Scientific and Technical Information (OSTI.GOV)
Iguchi, Toshihiro; Asami, Shinya; Kubo, Shinichiro
2007-11-15
A 66-year-old man underwent CT-guided drainage catheter placement within a pelvic abscess with a diameter of 46 mm. We performed the drainage by a transsacral approach because it was considered the safest and most feasible approach. An 8G bone marrow biopsy needle was used to penetrate the sacrum to create a path for subsequent drainage catheter insertion. After withdrawal of the biopsy needle, a 6 Fr catheter was advanced into the abscess cavity through the path using the Seldinger technique. Except for bearable pain, no procedure-related complications occurred. Twenty-nine days after the placement, the catheter was withdrawn safely and themore » abscess cavity had shrunk remarkably.« less
Maneval, Rhonda E; Clemence, Bonnie J
2014-01-01
This is the second part of a 2-part series that reports on the results of a prospective observational cohort study designed to examine risk factors associated with symptomatic upper extremity deep vein thrombosis (UEDVT) in patients with peripherally inserted central catheters (PICCs). Part 1, published in the May/June 2014 issue of the Journal of Infusion Nursing, provided an extensive review and critique of the literature regarding risk factors associated with catheter-related UEDVT and identified 28 suspected risk factors. A study was undertaken to examine each of the risk factors among 203 acute care patients with PICCs, 13 of whom experienced a UEDVT, yielding an incidence of 6.4%. The most common reason for admission was infection (33.5%), and the primary reason for insertion of the PICC was venous access (58.6%). Hypertension (P = .022) and obesity (P = .008), defined as a body mass index ≥30, were associated with UEDVT. The clinical symptoms of edema (P < .001) and a 3-cm or more increase in arm circumference (P < .001) in the PICC arm after PICC placement were associated with UEDVT. All other variables were not statistically significant. The results suggest that patients who are obese and hypertensive may be at greater risk for the development of UEDVT and that the physical finding of edema and increased arm circumference in the PICC arm are possibly suggestive of UEDVT.
Tian, Yuanshi; Xie, Xishao; Xiang, Shilong; Yang, Xin; Zhang, Xiaohui; Shou, Zhangfei; Chen, Jianghua
2016-12-01
Peritonitis remains a major complication of peritoneal dialysis (PD). A high peritonitis rate (HPR) affects continuous ambulatory peritoneal dialysis (CAPD) patients' technique survival and mortality. Predictors and outcomes of HPR, rather than the first peritonitis episode, were rarely studied in the Chinese population. In this study, we examined the risk factors associated with HPR and its effects on clinical outcomes in CAPD patients.This is a single center, retrospective, observational cohort study. A total of 294 patients who developing at least 1 episode of peritonitis were followed up from March 1st, 2002, to July 31, 2014, in our PD center. Multivariate logistic regression was used to determine the factors associated with HPR, and the Cox proportional hazard model was conducted to assess the effects of HPR on clinical outcomes.During the study period of 2917.5 patient-years, 489 episodes of peritonitis were recorded, and the total peritonitis rate was 0.168 episodes per patient-year. The multivariate analysis showed that factors associated with HPR include a quick occurrence of peritonitis after CAPD initiation (shorter than 12 months), and a low serum albumin level at the start of CAPD. In the Cox proportional hazard model, HPR was a significant predictor of technique failure. There were no differences between HPR and low peritonitis rate (LPR) group for all-cause mortality. However, when the peritonitis rate was considered as a continuous variable, a positive correlation was observed between the peritonitis rate and mortality.We found the quick peritonitis occurrence after CAPD and the low serum albumin level before CAPD were strongly associated with an HPR. Also, our results verified that HPR was positively correlated with technique failure. More importantly, the increase in the peritonitis rate suggested a higher risk of all-cause mortality.These results may help to identify and target patients who are at higher risk of HPR at the start of CAPD and to take interventions to reduce peritonitis incidence and improve clinical outcomes.
Tian, Yuanshi; Xie, Xishao; Xiang, Shilong; Yang, Xin; Zhang, Xiaohui; Shou, Zhangfei; Chen, Jianghua
2016-01-01
Abstract Peritonitis remains a major complication of peritoneal dialysis (PD). A high peritonitis rate (HPR) affects continuous ambulatory peritoneal dialysis (CAPD) patients’ technique survival and mortality. Predictors and outcomes of HPR, rather than the first peritonitis episode, were rarely studied in the Chinese population. In this study, we examined the risk factors associated with HPR and its effects on clinical outcomes in CAPD patients. This is a single center, retrospective, observational cohort study. A total of 294 patients who developing at least 1 episode of peritonitis were followed up from March 1st, 2002, to July 31, 2014, in our PD center. Multivariate logistic regression was used to determine the factors associated with HPR, and the Cox proportional hazard model was conducted to assess the effects of HPR on clinical outcomes. During the study period of 2917.5 patient-years, 489 episodes of peritonitis were recorded, and the total peritonitis rate was 0.168 episodes per patient-year. The multivariate analysis showed that factors associated with HPR include a quick occurrence of peritonitis after CAPD initiation (shorter than 12 months), and a low serum albumin level at the start of CAPD. In the Cox proportional hazard model, HPR was a significant predictor of technique failure. There were no differences between HPR and low peritonitis rate (LPR) group for all-cause mortality. However, when the peritonitis rate was considered as a continuous variable, a positive correlation was observed between the peritonitis rate and mortality. We found the quick peritonitis occurrence after CAPD and the low serum albumin level before CAPD were strongly associated with an HPR. Also, our results verified that HPR was positively correlated with technique failure. More importantly, the increase in the peritonitis rate suggested a higher risk of all-cause mortality. These results may help to identify and target patients who are at higher risk of HPR at the start of CAPD and to take interventions to reduce peritonitis incidence and improve clinical outcomes. PMID:27930566
Lehn, Robert A; Gross, Jeffrey B; McIsaac, Joseph H; Gipson, Keith E
2015-04-01
Although needleless connectors (NC) are frequently used in the perioperative setting, the potential of modern NCs to slow delivery of IV fluids has not been thoroughly studied. We examined flow characteristics of 5 NC models during pressurized delivery of crystalloid and banked red blood cells from a Level 1 warmer through various IV catheters. Crystalloid flow rates were reduced by 29% to 85% from control in catheters >18 gauge, while red blood cell flow reductions ranged from 22% to 76% in these catheters (all P < 0.0050). We suggest that practitioners consider eliminating NCs when large IV catheters are inserted for rapid fluid administration.
2012-01-01
Introduction Catheter-related bloodstream infections (CRBSIs) associated with short-term central venous catheters (CVCs) in intensive care unit (ICU) patients are a major clinical problem. Bacterial colonization of the skin at the CVC insertion site is an important etiologic factor for CRBSI. The aim of this study was to assess the efficacy of medical-grade honey in reducing bacterial skin colonization at insertion sites. Methods A prospective, single-center, open-label randomized controlled trial was performed at the ICU of a university hospital in The Netherlands to assess the efficacy of medical-grade honey to reduce skin colonization of insertion sites. Medical-grade honey was applied in addition to standard CVC-site dressing and disinfection with 0.5% chlorhexidine in 70% alcohol. Skin colonization was assessed on a daily basis before CVC-site disinfection. The primary end point was colonization of insertion sites with >100 colony-forming units at the last sampling before removal of the CVC or transfer of the patient from the ICU. Secondary end points were quantitative levels of colonization of the insertion sites and colonization of insertion sites stratified for CVC location. Results Colonization of insertion sites was not affected by the use of medical-grade honey, as 44 (34%) of 129 and 36 (34%) of 106 patients in the honey and standard care groups, respectively, had a positive skin culture (P = 0.98). Median levels of skin colonization at the last sampling were 1 (0 to 2.84) and 1 (0 to 2.70) log colony-forming units (CFUs)/swab for the honey and control groups, respectively (P = 0.94). Gender, days of CVC placement, CVC location, and CVC type were predictive for a positive skin culture. Correction for these variables did not change the effect of honey on skin-culture positivity. Conclusions Medical-grade honey does not affect colonization of the skin at CVC insertion sites in ICU patients when applied in addition to standard disinfection with 0.5% chlorhexidine in 70% alcohol. Trial registration Netherlands Trial Registry, NTR1652. PMID:23111148
Kwakman, Paulus H; Müller, Marcella C; Binnekade, Jan M; van den Akker, Johannes P; de Borgie, Corianne A; Schultz, Marcus J; Zaat, Sebastian A
2012-10-30
Catheter-related bloodstream infections (CRBSIs) associated with short-term central venous catheters (CVCs) in intensive care unit (ICU) patients are a major clinical problem. Bacterial colonization of the skin at the CVC insertion site is an important etiologic factor for CRBSI. The aim of this study was to assess the efficacy of medical-grade honey in reducing bacterial skin colonization at insertion sites. A prospective, single-center, open-label randomized controlled trial was performed at the ICU of a university hospital in The Netherlands to assess the efficacy of medical-grade honey to reduce skin colonization of insertion sites. Medical-grade honey was applied in addition to standard CVC-site dressing and disinfection with 0.5% chlorhexidine in 70% alcohol. Skin colonization was assessed on a daily basis before CVC-site disinfection. The primary end point was colonization of insertion sites with >100 colony-forming units at the last sampling before removal of the CVC or transfer of the patient from the ICU. Secondary end points were quantitative levels of colonization of the insertion sites and colonization of insertion sites stratified for CVC location. Colonization of insertion sites was not affected by the use of medical-grade honey, as 44 (34%) of 129 and 36 (34%) of 106 patients in the honey and standard care groups, respectively, had a positive skin culture (P = 0.98). Median levels of skin colonization at the last sampling were 1 (0 to 2.84) and 1 (0 to 2.70) log colony-forming units (CFUs)/swab for the honey and control groups, respectively (P = 0.94). Gender, days of CVC placement, CVC location, and CVC type were predictive for a positive skin culture. Correction for these variables did not change the effect of honey on skin-culture positivity. Medical-grade honey does not affect colonization of the skin at CVC insertion sites in ICU patients when applied in addition to standard disinfection with 0.5% chlorhexidine in 70% alcohol. Netherlands Trial Registry, NTR1652.
Stabille, Débora Miranda Diogo; Filho, Augusto Diogo; Mandim, Beatriz Lemos da Silva; Araújo, Lúcio Borges de; Mesquita, Priscila Miranda Diogo; Jorge, Miguel Tanús
2015-01-01
The increased use of epidural analgesia with catheter leads to the need to demonstrate the safety of this method and know the incidence of catheter colonization, inserted postoperatively for epidural analgesia, and the bacteria responsible for this colonization. From November 2011 to April 2012, patients electively operated and maintained under epidural catheter for postoperative analgesia were evaluated. The catheter tip was collected for semiquantitative and qualitative microbiological analysis. Of 68 cultured catheters, six tips (8.8%) had positive cultures. No patient had superficial or deep infection. The mean duration of catheter use was 43.45hours (18-118) (p=0.0894). The type of surgery (contaminated or uncontaminated), physical status of patients, and surgical time showed no relation with the colonization of catheters. Microorganisms isolated from the catheter tip were Staphylococcus aureus, Pseudomonas aeruginosa and Sphingomonas paucimobilis. Postoperative epidural catheter analgesia, under this study conditions, was found to be low risk for bacterial colonization in patients at surgical wards. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.
Stabille, Débora Miranda Diogo; Diogo Filho, Augusto; Mandim, Beatriz Lemos da Silva; de Araújo, Lúcio Borges; Mesquita, Priscila Miranda Diogo; Jorge, Miguel Tanús
2015-01-01
The increased use of epidural analgesia with catheter leads to the need to demonstrate the safety of this method and know the incidence of catheter colonization, inserted postoperatively for epidural analgesia, and the bacteria responsible for this colonization. From November 2011 to April 2012, patients electively operated and maintained under epidural catheter for postoperative analgesia were evaluated. The catheter tip was collected for semiquantitative and qualitative microbiological analysis. Of 68 cultured catheters, six tips (8.8%) had positive cultures. No patient had superficial or deep infection. The mean duration of catheter use was 43.45 h (18-118) (p=0.0894). The type of surgery (contaminated or uncontaminated), physical status of patients, and surgical time showed no relation with the colonization of catheters. Microorganisms isolated from the catheter tip were Staphylococcus aureus, Pseudomonas aeruginosa and Sphingomonas paucimobilis. Postoperative epidural catheter analgesia, under these study conditions, was found to be low risk for bacterial colonization in patients at surgical wards. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, W; Damato, A; Viswanathan, A
2014-06-15
Purpose: To develop a novel active MR-tracking system which can provide accurate and rapid localization of brachytherapy catheters, and assess its reliability and spatial accuracy in comparison to standard catheter digitization using MR images. Methods: An active MR tracker for brachytherapy was constructed by adding three printed-circuit micro-coils to the shaft of a commercial metallic stylet. A gel phantom with an embedded framework was built, into which fifteen 14-Gauge catheters were placed, following either with parallel or crossed paths. The tracker was inserted sequentially into each catheter, with MR-tracking running continuously. Tracking was also performed during the tracker's removal frommore » each catheter. Catheter trajectories measured from the insertion and the removal procedures using the same micro-coil were compared, as well as trajectories obtained using different micro-coils. A 3D high-resolution MR image dataset of the phantom was acquired and imported into a treatment planning system (TPS) for catheter digitization. A comparison between MR-tracked positions and positions digitized from MR images by TPS was performed. Results: The MR tracking shows good consistency for varying catheter paths and for all micro-coils (mean difference ∼1.1 mm). The average distance between the MR-tracking trajectory and catheter digitization from the MR images was 1.1 mm. Ambiguity in catheter assignment from images due to crossed paths was resolved by active tracking. When tracking was interleaved with imaging, real-time images were continuously acquired at the instantaneous tip positions and displayed on an external workstation. Conclusion: The active MR tracker may be used to provide an independent measurement of catheter location in the MR environment, potentially eliminating the need for subsequent CT. It may also be used to control realtime imaging of catheter placement. This will enable MR-based brachytherapy planning of interstitial implants without ionizing radiation, with the potential to enable dosimetric guidance of catheter placement. We gratefully acknowledge support from the American Heart Association SDG 10SDG2610139, NIH 1R21CA158987-01A1, U41-RR019703, and R21 CA 167800, as well as a BWH Department of Radiation Oncology post-doctoral fellowship support. Li Pan and Wesley Gilson are employees of Siemens Corporation, Corporate Technology. Ravi Seethamraju is an employee of Siemens Healthcare.« less
Using electrical impedance to predict catheter-endocardial contact during RF cardiac ablation.
Cao, Hong; Tungjitkusolmun, Supan; Choy, Young Bin; Tsai, Jang-Zern; Vorperian, Vicken R; Webster, John G
2002-03-01
During radio-frequency (RF) cardiac catheter ablation, there is little information to estimate the contact between the catheter tip electrode and endocardium because only the metal electrode shows up under fluoroscopy. We present a method that utilizes the electrical impedance between the catheter electrode and the dispersive electrode to predict the catheter tip electrode insertion depth into the endocardium. Since the resistivity of blood differs from the resistivity of the endocardium, the impedance increases as the catheter tip lodges deeper in the endocardium. In vitro measurements yielded the impedance-depth relations at 1, 10, 100, and 500 kHz. We predict the depth by spline curve interpolation using the obtained calibration curve. This impedance method gives reasonably accurate predicted depth. We also evaluated alternative methods, such as impedance difference and impedance ratio.
Powell, Steven; Chan, Tze Yuan; Bhat, Rammohan; Lam, Kimberly; Narlawar, Ranjeet S; Cullen, Nicola; Littler, Peter
2010-08-01
Tunneled hemodialysis catheters become essential in dialysis access when there is no possibility of using a functioning arteriovenous fistula. Collateral or occluded veins visible on ultrasound are used for puncture and passage of catheters into the central venous system. Chronically occluded veins are crossed with guidewires to allow dilatation and subsequent passage of hemodialysis catheters. We performed a retrospective analysis of patient demographics, comorbidities, procedural complications, functional survival, performance, and history of previous vascular access. The study group was compared with two control groups in which dialysis catheters were inserted either by radiologists in the interventional suite or by clinicians on the wards. Nineteen patients from the study group were compared with same number of patients in both control groups. The mean age of the study group was higher compared with the control groups. There was no significant difference in mean functional survival, infection rates, dialysis pump speeds in the first 2 weeks, and procedural complications between the study group and the controls. The study group had a significantly higher number of previous vascular access interventions, longer dialysis careers, and more comorbidities. Tunneled dialysis catheter placement by way of collateral or occluded veins appears safe and effective. These techniques give the operator further options when faced with patients possessing challenging vascular access. Indeed, there may be a case for preferential use of these veins to keep patent central veins in reserve.
Peripheral intravenous catheter-related phlebitis and related risk factors.
Nassaji-Zavareh, M; Ghorbani, R
2007-08-01
Peripheral intravenous catheter-related phlebitis is a common and significant problem in clinical practice. This study aims to investigate the incidence of phlebitis and to evaluate some important related factors. 300 patients admitted to medical and surgical wards of hospitals in Semnan, Iran from April 2003 to February 2004 were prospectively studied. Variables evaluated were age, gender, site and size of catheter, type of insertion and underlying conditions (diabetes mellitus, trauma, infectious disease and burns). Phlebitis was defined when at least four criteria were fulfilled (erythema, pain, tenderness, warmth, induration, palpable cord and swelling). Any patient who was discharged or their catheter removed before three days were excluded. Phlebitis occurred in 26 percent (95 percent confidence interval [CI] 21- 31 percent) of patients. There was no significant relationship between age, catheter bore size, trauma and phlebitis. Related risk factors were gender (odds-ratio [OR] 1.50, 95 percent CI 1.01-2.22), site (OR 3.25, 95 percent CI 2.26-4.67) and type of insertion (OR 2.04, 95 percent CI 1.36-3.05) of catheter, diabetes mellitus (OR 7.78, 95 percent CI 4.59-13.21), infectious disease (OR 6.21, 95 percent CI 4.27-9.03) and burns (OR 3.96, 95 percent CI 3.26-4.82). Phlebitis is still an important and ongoing problem in medical practice. In patients with diabetes mellitus and infectious diseases, more attention is needed.
Kadiroğlu, A K; Ustündag, S; Kayabaşi, H; Yilmaz, Z; Yildirım, Y; Sen, S; Yilmaz, M E
2013-09-01
Dyslipidemia is frequent in patients with end stage renal disease. Excessive peritoneal glucose absorption from high glucose-containing peritoneal dialysis solutions may enhance disturbances on the lipid metabolism of patients on peritoneal dialysis. We compared the effect of icodextrin-based peritoneal dialysis therapy with hemodialysis (HD) therapy on lipid metabolism. A total of 157 non-diabetic patients on dialysis at least for 3 months; 78 patients on Icodextrin-based continuous ambulatory peritoneal dialysis (CAPD) (44 M, 34 F) and 79 patients in HD group (47M, 32F) were included into the study. After 12 h of fasting and before the dialysis session, serum urea, creatinin, glucose, Sodium, potasium, and albumin, total cholesterol (TC), triglycerides (TG), very low density lipoprotein (VLDL), low density lipoprotein (LDL)-C, high-density lipoprotein (HDL)-C, apolipoprotein A (Apo A), apolipoprotein B, and lipoprotein a were measured. TG (P = 0018) and VLDL (P = 0.022) were lower in CAPD group than HD group, HDL-C (P < 0.001) and Apo A (P = 0.001) were higher in CAPD group than in HD group. A total of 24.4% in CAPD group and 11.4% in HD group (P < 0.034) had normal serum levels of TG, LDL-C, and HDL-C. More patients in CAPD group (47.4%) had high serum Apo A levels than in HD group (21.5%) (P = 0.001). We suggest that patients receiving icodextrin-based CAPD may have better TG, HDL-C, and Apo A levels than patients on HD.
Benabed, Anais; Bechade, Clemence; Ficheux, Maxence; Verger, Christian; Lobbedez, Thierry
2016-04-01
Diabetic patients treated by peritoneal dialysis (PD) have been reported to be at an increased risk of peritonitis. This has been attributed to impairment in host defense, visual impairment, disability and muscle wasting, which could compromise ability to safely perform catheter connections. This study aimed to evaluate whether assisted PD is associated with a lower risk of peritonitis in diabetic patients. This was a retrospective study based on data from the French Language Peritoneal Dialysis Registry. We included diabetic patients starting PD between 1 January 2002 and 31 December 2012. The end of the observation period was 31 December 2013. Using complementary regression analysis (Fine and Gray, Hurdle models), we assessed the relationship between peritonitis occurrence, peritonitis number over time and the type of assisted PD. Of the 3598 diabetic patients, there were 2040 patients on nurse-assisted PD. These patients were older, more comorbid and more frequently on continuous ambulatory peritoneal dialysis (CAPD). In the multivariate analysis, nurse assistance was associated with a reduced risk of peritonitis in the Fine and Gray [subdistribution hazard ratio: 0.78 (95% confidence interval, CI, 0.68-0.89)] and in the first component of the Hurdle models [rate ratio: 0.82 (95% CI 0.71-0.93)], but not a lower incidence of peritonitis after an initial episode [rate ratio: 0.82 (95% CI 0.95-1.38)]. Transplant failure, glomerulonephritis and CAPD were associated with an increased risk. In France, nurse-assisted PD is associated with a lower risk of peritonitis in diabetic patients treated by PD but not a lower incidence of peritonitis. © The Author 2016. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.
Sofroniadou, Sofia; Revela, Ioanna; Kouloubinis, Alexandros; Makriniotou, Ioanna; Zerbala, Sinodi; Smirloglou, Despina; Kalocheretis, Petros; Drouzas, Apostolos; Samonis, George; Iatrou, Christos
2017-10-01
Ethanol lock solution has been mainly administered in paediatric and home parenteral nutrition patients in order to prevent catheter related blood stream infections (CRBSI). Its utility in hemodialysis (HD) patients with non-tunneled-uncuffed catheter (NTC) has been poorly explored. We conducted a prospective randomized study in chronic HD patients requiring a newly inserted NTC-while awaiting for the maturation of an already established arteriovenous fistula (AVF) or arteriovenous graft (AVG) or tunneled-cuffed catheter insertion. Patients were randomized in two groups: Group A, where the lock solution was ethanol 70% + unfractionated heparin 2000 U/mL and group B, that received only unfractionated heparin 2000 U/mL. Primary end point was CRBSIs whereas exit site infections, thrombotic and bleeding episodes were the secondary end points. One hundred three HD patients were enrolled in the study (group A, n = 52; group B, n = 51). The median number of catheter days was 32 for group A (range: 23-39) and 34 (range: 27-40) for group B with no statistically significant difference between the two groups. Group A (ethanol + heparin) demonstrated 4/52 episodes (7.69%) of CRBSI whereas Group B (heparin) 11/51 episodes (21.57%) (P = 0.04). CRBSI rates per 1000 catheter days were 2.53/1000 catheter days for group A and 6.7/1000 catheter days for group B (P = 0.04). Mean cumulative infection-free catheter survival in the ethanol group did not differ significantly compared to the heparin group (log-rank test = 2.99, P = 0.08). Thrombotic episodes did not differ between the two groups. Locking of NTCs in HD patients with ethanol 70% + unfractionated heparin reduces CRBSI rates without increasing the thrombotic episodes. © 2017 International Society for Hemodialysis.
Acute Urinary Obstruction in a Tetraplegic Patient from Misplacement of Catheter in Urethra.
Vaidyanathan, Subramanian; Singh, Gurpreet; Hughes, Peter L; Soni, Bakul M
2016-01-01
A male tetraplegic patient attended accident and emergency with a blocked catheter; on removing the catheter, he passed bloody urine. After three unsuccessful attempts were made to insert a catheter by nursing staff, a junior doctor inserted a three-way Foley catheter with a 30-mL balloon but inflated the balloon with 10 mL of water to commence the bladder irrigation. The creatinine level was mostly 19 µmol/L (range: 0-135 µmol/L) but increased to 46 µmol/L on day 7. Computerized tomography urogram revealed that the bilateral hydronephrosis with hydroureter was extended down to urinary bladder, the bladder was distended, prostatic urethra was dilated and filled with urine, and although the balloon of Foley catheter was not seen in the bladder, the tip of the catheter was seen lying in the urethra. Following the re-catheterization, the creatinine level decreased to 21 µmol/L. A follow-up ultrasound scan revealed no evidence of hydronephrosis in both kidneys. Flexible cystoscopy revealed inflamed bladder mucosa, catheter reaction, and tiny stones. There was no bladder tumor. This case report concludes that the cause of bilateral hydronephrosis, hydroureter, and distended bladder was inadequate drainage of urinary bladder as the Foley balloon that was under-filled slipped into the urethra resulting in an obstruction to urine flow. Urethral catheterization in tetraplegic patients should be performed by senior, experienced staff in order to avoid trauma and incorrect positioning. Tetraplegic subjects with decreased muscle mass have low creatinine level. Increase in creatinine level (>1.5 times the basal level) indicates acute kidney injury, although peak creatinine level may still be within laboratory reference range. While scanning the urinary tract of spinal cord injury patients with indwelling urinary catheter, if Foley balloon is not seen within the bladder, urethra should be scanned to locate the Foley balloon.
Insertion of tunneled hemodialysis catheters without fluoroscopy.
Motta Elias, Rosilene; da Silva Makida, Sonia Cristina; Abensur, Hugo; Martins Castro, Manuel Carlos; Affonso Moysés, Rosa Maria; Pereira, Benedito Jorge; Bueno de Oliveira, Rodrigo; Luders, Cláudio; Romão, João Egidio
2010-01-01
The tunneled cuffed catheter (TCC) is used as a bridge access for hemodialysis. Few prospective studies have been designed to evaluate conversion from non-tunneled to TCC without the use of fluoroscopy when performed by nephrologists. We performed an observational prospective cohort in incident patients receiving hemodialysis through a non-tunneled right jugular vein catheter. 130 procedures were performed in 122 patients (51+/-18 years). The success rate was 100%. There was a total of 26,546 catheter days. Ninety-one of the 130 catheters were removed during the study period. Life table analysis revealed primary patency rates of 92%, 82%, and 68% at 30, 60, and 120 days, respectively. Infection requiring catheter removal occurred at a frequency of 0.09 per 100 catheter days. Catheter malfunction requiring intervention occurred at a rate of 0.03 per 100 catheter days. Hypertension and duration of existing non-tunneled catheter of less than 2 weeks were independently associated with better TCC survival. The conversion from non-tunneled to TCC performed by nephrologists and without fluoroscopy may be safe by using the internal right jugular vein. The ideal time to do this procedure is within less than 2 weeks of existing non-tunneled catheter.
Behavioral Indications of Auditory Processing Disorders.
ERIC Educational Resources Information Center
Hartman, Kerry McGoldrick
1988-01-01
Identifies disruptive behaviors of children that may indicate central auditory processing disorders (CAPDs), perceptual handicaps of auditory discrimination or auditory memory not related to hearing ability. Outlines steps to modify the communication environment for CAPD children at home and in the classroom. (SV)
Li, Philip Kam-Tao; Chung, Kwok Yi; Chow, Kai Ming
2007-06-01
This article examines the roles of continuous ambulatory peritoneal dialysis (CAPD) versus automated peritoneal dialysis (APD) as first-line renal replacement therapy. To date, no high-quality large-scale randomized controlled studies have compared CAPD with APD as first-line therapy. However, a discussion on this issue is important so that nephrologists can decide and patients can have a choice of modality on which to start dialysis, especially in the context of health care economics. We review the literature and present Hong Kong as the model of a "CAPD first" policy, an appealing, cost-effective approach for any country. An ideal renal replacement therapy should provide optimal survival, lowest possible risk for comorbidity, highest level of quality of life, and equally important, acceptable cost to society. When we consider this subject in the context that all patients should be started on one first-line modality, the data suggest that a "CAPD first" policy has all these advantages, with APD probably having the edge only with regard to patient preference. The present review highlights preservation of residual renal function, removal and balancing of sodium, incidence of peritonitis, peritoneal membrane transport status, patient rehabilitation, and financial issues in demonstrating that a "CAPD first" policy is the model that should be adopted.
Modelling catheter-vein biomechanical interactions during an intravenous procedure.
Weiss, Dar; Gefen, Amit; Einav, Shmuel
2016-02-01
A reliable intravenous (IV) access into the upper extremity veins requires the insertion of a temporary short peripheral catheter (SPC). This so common procedure is, however, associated with a risk of developing short peripheral catheter thrombophlebitis (SPCT) which causes distress and potentially prolongs patient hospitalization. We have developed and studied a biomechanical SPC-vein computational model during an IV procedure, and explored the biomechanical effects of repeated IV episodes on onset and reoccurrences of SPCT. The model was used to determine the effects of different insertion techniques as well as inter-patient biological variability on the catheter-vein wall contact pressures and wall deformations. We found that the maximal pressure exerted upon the vein wall was inhomogeneously distributed, and that the bending region was exposed to significantly greater pressures and deformations. The maximal exerted contact pressure on the inner vein's wall was 2938 Pa. The maximal extent of the SPC penetration into the vein wall reached 3.6 μm, which corresponds to approximately 100% of the average height of the inner layer, suggesting local squashing of endothelial cells at the contact site. The modelling describes a potential biomechanical damage pathway that can explain the reoccurrence of SPCT.
Erdogan, Hakan; Altun, Adnan; Kuruoglu, Enis; Kaya, Ahmet Hilmi; Dagcinar, Adnan
2017-09-26
Ventriculoatrial (VA) shunting is a well-described cerebrospinal fluid diversion method for the treatment of hydrocephalus. However, it may be very challenging in infants and little children because of atrial catheter placement difficulties. This study aimed to create an algorithm to solve problems faced during open surgical procedures based on the present authors' experience. We conducted a retrospective analysis on 18 infants and children who underwent VA shunt insertion at the Department of Neurosurgery, Ondokuz Mayıs University School of Medicine Hospital between 2005 and 2012. Complications, clinical outcomes, revisions, and solutions for overcoming distal catheter placement difficulties were evaluated. Twenty-six VA shunt operations were performed in 18 patients. Six patients required eight VA shunt revisions. VA shunting was primarily performed from the internal jugular, facial, cephalic, and subclavian veins to the right atrium. In revision procedures, the internal jugular, cephalic, and subclavian veins were used. VA shunting in infants and little children requires careful surgical techniques. Neurosurgeons should necessarily have an appropriate strategy for VA shunting considering the complications and revisions. Our results suggest open surgical solutions to overcome distal catheter placement difficulties in this age group.
Managing Inadvertent Arterial Catheterization During Central Venous Access Procedures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nicholson, Tony, E-mail: Tony.Nicholson@leedsth.nhs.uk; Ettles, Duncan; Robinson, Graham
2004-01-15
Purpose: Approximately 200,000 central venous catheterizations are carried out annually in the National Health Service in the United Kingdom. Inadvertent arterial puncture occurs in up to 3.7%. Significant morbidity and death has been reported. We report on our experience in the endovascular treatment of this iatrogenic complication. Methods: Retrospective analysis was carried out of 9 cases referred for endovascular treatment of inadvertent arterial puncture during central venous catheterization over a 5 year period. Results: It was not possible to obtain accurate figures on the numbers of central venous catheterizations carried out during the time period. Five patients were referred withmore » carotid or subclavian pseudoaneurysms and hemothorax following inadvertent arterial catheter insertion and subsequent removal. These patients all underwent percutaneous balloon tamponade and/or stent-graft insertion. More recently 4 patients were referred with the catheter still in situ and were successfully treated with a percutaneous closure device. Conclusion: If inadvertent arterial catheterization during central venous access procedures is recognized and catheters removed, sequelae can be treated percutaneously. However, once the complication is recognized it is better to leave the catheter in situ and seal the artery percutaneously with a closure device.« less
Merchaoui, Zied; Lausten-Thomsen, Ulrik; Pierre, Florence; Ben Laiba, Maher; Le Saché, Nolwenn; Tissieres, Pierre
2017-01-01
The correct choice of intra vascular access in critically ill neonates should be individualized depending on the type and duration of therapy, gestational and chronological age, weight and/or size, diagnosis, clinical status, and venous system patency. Accordingly, there is an ongoing demand for optimization of catheterization. Recently, the use of ultrasound (US)-guided cannulation of the subclavian vein (SCV) has been described in children and neonates. This article gives an overview of the current use of US for achieving central venous catheter placement in the SCV or the brachiocephalic vein (BCV) in neonates. More than 1,250 catheters have been reported inserted in children and neonates for a cumulated success rate of 98.4% and the complication rate is reported to be low. The technical aspects of various approaches are discussed, and we offer our recommendation of an US-guided technique for SCV and BCV cannulation based on our experience in a large NICU setting. Although the cannulation the SCV or BCV does not substitute the use of peripherally inserted central catheters or umbilical venous central catheters in neonates, it is a feasible route in very small children who are in need of a large caliber central venous access. PMID:29051889
Benaya, A; Schwartz, Y; Kory, R; Yinnon, A M; Ben-Chetrit, E
2015-05-01
Peripheral venous access in elderly, hospitalized patients is often challenging. The usual alternative is insertion of a central venous catheter, with associated risk for complications. The purpose of this investigation was to determine the relative incidence of phlebitis secondary to lower as compared to upper extremity intravenous catheters (IVCs) and associated risk factors. A non-randomized, observational, cohort-controlled study was carried out. Consecutive patients receiving a lower extremity IVC were enrolled and compared with patients receiving an upper extremity IVC. Patients were followed from insertion until removal of the IVC. The major endpoint was phlebitis. The incidence of phlebitis secondary to upper extremity IVCs was 3/50 (6 %) compared to 5/53 (9.4 %) in lower extremity IVCs (χ(2) Yates = 0.08, p = 0.776). Age, gender, obesity, diabetes mellitus, site (arm versus leg, left versus right), and size of needle were not found to be risk factors for phlebitis according to univariate analysis. None of the patients developed bloodstream infection. In elderly patients with poor venous access, lower extremity IVCs are a reasonable and low-risk alternative to central venous catheters.
Kristiniak, Susan; Harpel, Jean; Breckenridge, Diane M; Buckle, Jane
2012-11-01
To evaluate the effect of topically applied black pepper essential oil on easing intravenous catheter insertion (IVC) in patients with no palpable or visible veins compared to a control group (standard nursing practice). Randomized, controlled study. One hundred twenty hospitalized patients, who were referred to a hospital vascular team because of difficulty in accessing veins for IVC insertion. Topical application of 20% essential oil of black pepper in aloe vera gel or standard nursing care (hot packs with or without vigorous tactile stimulation). Pre- and post-test vein visibility and/or palpability and number of attempts at IVC insertion. A higher percentage of patients achieved optimal scoring (vein score=2) or improved scoring (vein score of 1 or 2) to black pepper intervention than standard nursing care. The black pepper group also reduced the number of patients whose veins were still not visible or palpable after the intervention to nearly half that of the control group (p<0.05). The number of IVC attempts following black pepper was also half that of the control group. Topical application of black pepper is a viable and effective way to enhance vein visibility and palpability prior to intravenous insertion in patients with limited vein accessibility; it also improves ease of IVC insertion.
Prevention of catheter-related blood stream infection.
Byrnes, Matthew C; Coopersmith, Craig M
2007-08-01
Catheter-related blood stream infections are a morbid complication of central venous catheters. This review will highlight a comprehensive approach demonstrated to prevent catheter-related blood stream infections. Elements of prevention important to inserting a central venous catheter include proper hand hygiene, use of full barrier precautions, appropriate skin preparation with 2% chlorhexidine, and using the subclavian vein as the preferred anatomic site. Rigorous attention needs to be given to dressing care, and there should be daily assessment of the need for central venous catheters, with prompt removal as soon as is practicable. Healthcare workers should be educated routinely on methods to prevent catheter-related blood stream infections. If rates remain higher than benchmark levels despite proper bedside practice, antiseptic or antibiotic-impregnated catheters can also prevent infections effectively. A recent program utilizing these practices in 103 ICUs in Michigan resulted in a 66% decrease in infection rates. There is increasing recognition that a comprehensive strategy to prevent catheter-related blood stream infections can prevent most infections, if not all. This suggests that thousands of infections can potentially be averted if the simple practices outlined herein are followed.
Determining the best catheter for sonohysterography.
Dessole, S; Farina, M; Capobianco, G; Nardelli, G B; Ambrosini, G; Meloni, G B
2001-09-01
To compare the characteristics of six different catheters for performing sonohysterography (SHG) to identify those that offer the best compromise between reliability, tolerability, and cost. Prospective study. University hospital. Six hundred ten women undergoing SHG. We performed SHG with six different types of catheters: Foleycath (Wembley Rubber Products, Sepang, Malaysia), Hysca Hysterosalpingography Catheter (GTA International Medical Devices S.A., La Caleta D.N., Dominican Republic), H/S Catheter Set (Ackrad Laboratories, Cranford, NJ), PBN Balloon Hystero-Salpingography Catheter (PBN Medicals, Stenloese, Denmark), ZUI-2.0 Catheter (Zinnanti Uterine Injection; BEI Medical System International, Gembloux, Belgium), and Goldstein Catheter (Cook, Spencer, IN). We assessed the reliability, the physician's ease of use, the time requested for the insertion of the catheter, the volume of contrast medium used, the tolerability for the patients, and the cost of the catheters. In 568 (93%) correctly performed procedures, no statistically significant differences were found among the catheters. The Foleycath was the most difficult for the physician to use and required significantly more time to position correctly. The Goldstein catheter was the best tolerated by the patients. The Foleycath was the cheapest whereas the PBN Balloon was the most expensive. The choice of the catheter must be targeted to achieving a good balance between tolerability for the patients, efficacy, cost, and the personal preference of the operator.
Carter, Eileen J; Pallin, Daniel J; Mandel, Leslie; Sinnette, Corine; Schuur, Jeremiah D
2016-10-01
The aim of this study was to explore the actions of nurse leaders that facilitated clinical nurses' active involvement in emergency department (ED) catheter-associated urinary tract infection (CAUTI) prevention programs. Hospitals face increasing financial pressures to reduce CAUTI. Urinary catheters, often inserted in the ED, expose patients to CAUTI risk. Nurses are the principal champions of ED CAUTI prevention programs. This was a qualitative analysis from a multisite, comparative case study project. A total of 52 interviews and 9 focus groups were analyzed across 6 enrolled EDs. Using a conventional content analysis, members of the research team coded data and developed site summaries to describe themes that had emerged across transcripts. Subsequently, all codes and site summaries were reviewed to identify the actions of nurse leaders that facilitated clinical nurses' engagement in CAUTI prevention efforts. Nurse leaders were the principal champions of CAUTI prevention programs and successfully engaged clinical nurses in CAUTI prevention efforts by (1) reframing urinary catheters as a source of potential patient harm; (2) empowering clinical nurses to identify and address CAUTI improvement opportunities; (3) fostering a culture of teamwork, which facilitated interdisciplinary communication around urinary catheter appropriateness and alternatives; and (4) holding clinical nurses accountable for CAUTI process and outcome measures. The prevention of CAUTI is an important opportunity for nurse leaders to engage clinical nurses in meaningful improvement efforts. Clinical nurses are best positioned to examine urinary catheter insertion workflow and to suggest improvements in avoiding use and improving placement and maintenance. To engage clinical nurses in CAUTI prevention, nurse leaders should focus on how urinary catheters expose patients to potential harm, involve nurses in designing and implementing practice changes, and provide local data to show the impact of nursing practices on patient outcomes.
Intraluminal pneumatic lithotripsy for the removal of encrusted urinary catheters.
Canby-Hagino, E D; Caballero, R D; Harmon, W J
1999-12-01
Urologists frequently treat patients requiring long-term urinary drainage with a percutaneous nephrostomy tube or ureteral stent. When such tubes are neglected and become encrusted, removal challenges even experienced urologists. We describe a new, minimally invasive technique for safely and rapidly removing encrusted, occluded tubes using the Swiss Lithoclast pneumatic lithotriptor. Patients presenting with an encrusted urinary catheter were evaluated by excretory urography for renal function and obstruction. Gentle manual extraction of the tube was attempted, followed by traditional extracorporeal shock wave lithotripsy and/or ureteroscopy. When the tube was not extracted, patients were then treated with intraluminal insertion of a pneumatic lithotripsy probe. One patient presented with an encrusted, occluded nephrostomy tube and 2 had an encrusted, occluded, indwelling ureteral stent. None was removed by manual traction. Intraluminal encrustations prevented the pigtail portions of these tubes from uncoiling and removal. In each case a pneumatic lithotripsy probe was inserted into the lumen of the catheter and advanced in a jackhammer-like fashion. This technique resulted in disruption of the intraluminal encrustations and straightening of the tubes so that they were removed in an atraumatic manner. Intraluminal pneumatic lithotripsy is a safe, easy and rapid technique for removing encrusted urinary catheters. It is unique in that the pneumatic lithotripsy probe functions in an aqueous and nonaqueous environment, and dislodges intraluminal calcifications. We recommend its use as first line treatment for removing encrusted urinary catheters.
Economic impact of Tegaderm chlorhexidine gluconate (CHG) dressing in critically ill patients.
Thokala, Praveen; Arrowsmith, Martin; Poku, Edith; Martyn-St James, Marissa; Anderson, Jeff; Foster, Steve; Elliott, Tom; Whitehouse, Tony
2016-09-01
To estimate the economic impact of a Tegaderm TM chlorhexidine gluconate (CHG) gel dressing compared with a standard intravenous (i.v.) dressing (defined as non-antimicrobial transparent film dressing), used for insertion site care of short-term central venous and arterial catheters (intravascular catheters) in adult critical care patients using a cost-consequence model populated with data from published sources. A decision analytical cost-consequence model was developed which assigned each patient with an indwelling intravascular catheter and a standard dressing, a baseline risk of associated dermatitis, local infection at the catheter insertion site and catheter-related bloodstream infections (CRBSI), estimated from published secondary sources. The risks of these events for patients with a Tegaderm CHG were estimated by applying the effectiveness parameters from the clinical review to the baseline risks. Costs were accrued through costs of intervention (i.e. Tegaderm CHG or standard intravenous dressing) and hospital treatment costs depended on whether the patients had local dermatitis, local infection or CRBSI. Total costs were estimated as mean values of 10,000 probabilistic sensitivity analysis (PSA) runs. Tegaderm CHG resulted in an average cost-saving of £77 per patient in an intensive care unit. Tegaderm CHG also has a 98.5% probability of being cost-saving compared to standard i.v. dressings. The analyses suggest that Tegaderm CHG is a cost-saving strategy to reduce CRBSI and the results were robust to sensitivity analyses.
Peritoneal dialysis catheter implantation: avoiding problems and optimizing outcomes.
Crabtree, John H
2015-01-01
The success of peritoneal dialysis (PD) as renal replacement therapy is dependent upon the patient having a functional long-term peritoneal access. There are a number of identified best practices that must be adhered to during PD catheter placement to achieve a durable and infection-resistant access. The clinical setting, available resources, and the employed catheter insertion method may not always permit complete adherence to these practices; however, an attempt should be made to comply with them as closely as possible. Although omission of any one of the practices can lead to catheter loss, departures from some are committed more frequently, manifesting as commonly occurring clinical problems, such as drain pain, catheter tip migration, omental entrapment, pericatheter leaks and hernias, and poor exit-site location. Understanding the technical pitfalls in PD catheter placement that lead to these problems, enable the provider to modify practice habits to avoid them and optimize outcomes. © 2014 Wiley Periodicals, Inc.
Catheter tip force transducer for cardiovascular research
NASA Technical Reports Server (NTRS)
Feldstein, C.; Lewis, G. W.; Silver, R. H.; Culler, V. H. (Inventor)
1976-01-01
A force transducer for measuring dynamic force activity within the heart of a subject essentially consists of a U-shaped beam of low elastic compliance material. Two lines extend from the beams's legs and a long coil spring is attached to the beam. A strain gauge is coupled to one of the beam's legs to sense deflections thereof. The beam with the tines and most of the spring are surrounded by a flexible tube, defining a catheter, which is insertable into a subject's heart through an appropriate artery. The tines are extractable from the catheter for implantation into the myocardium by pushing on the end of the spring which extends beyond the external end of the catheter.
Milner, Rafał; Lewandowska, Monika; Ganc, Małgorzata; Włodarczyk, Elżbieta; Grudzień, Diana; Skarżyński, Henryk
2018-01-01
In this study, we showed an abnormal resting-state quantitative electroencephalogram (QEEG) pattern in children with central auditory processing disorder (CAPD). Twenty-seven children (16 male, 11 female; mean age = 10.7 years) with CAPD and no symptoms of other developmental disorders, as well as 23 age- and sex-matched, typically developing children (TDC, 11 male, 13 female; mean age = 11.8 years) underwent examination of central auditory processes (CAPs) and QEEG evaluation consisting of two randomly presented blocks of “Eyes Open” (EO) or “Eyes Closed” (EC) recordings. Significant correlations between individual frequency band powers and CAP tests performance were found. The QEEG studies revealed that in CAPD relative to TDC there was no effect of decreased delta absolute power (1.5–4 Hz) in EO compared to the EC condition. Furthermore, children with CAPD showed increased theta power (4–8 Hz) in the frontal area, a tendency toward elevated theta power in EO block, and reduced low-frequency beta power (12–15 Hz) in the bilateral occipital and the left temporo-occipital regions for both EO and EC conditions. Decreased middle-frequency beta power (15–18 Hz) in children with CAPD was observed only in the EC block. The findings of the present study suggest that QEEG could be an adequate tool to discriminate children with CAPD from normally developing children. Correlation analysis shows relationship between the individual EEG resting frequency bands and the CAPs. Increased power of slow waves and decreased power of fast rhythms could indicate abnormal functioning (hypoarousal of the cortex and/or an immaturity) of brain areas not specialized in auditory information processing.
Azithromycin: an assessment of its pharmacokinetics and therapeutic potential in CAPD.
Kent, J R; Almond, M K; Dhillon, S
2001-01-01
Azithromycin is an azalide antibiotic with a similar antibacterial spectrum to erythromycin but with greater gram-negative activity. Azithromycin displays a favorable pharmacokinetic profile, with improved absorption and higher sustained tissue concentrations compared with erythromycin. This results in a prolonged elimination half-life, suggesting a potential for treating continuous ambulatory peritoneal dialysis (CAPD) peritonitis. This study aimed to define the potential role of azithromycin in treating CAPD peritonitis. The pharmacokinetics and peritoneal dialysis (PD) clearance of azithromycin were studied following a single 500-mg oral dose of azithromycin. Blood and dialysate samples were taken over a 10-day period and assayed using high-pressure liquid chromatography. The study took place within the Renal Unit at Southend Hospital NHS Trust, a district general hospital in the United Kingdom. Eight patients with oliguric end-stage renal failure without peritonitis maintained on CAPD (3 x 2 L/day). Peak plasma concentrations occurred at 2-3 hours with 0.35-1.35 microg/mL (mean 0.75). The mean elimination half-life was 84.55 hrs, and plasma clearance was 21.93 L/hour. This compares with values of greater than 40 hours and 40.8 L/hour reported in healthy volunteers. After 8 hours, the mean dialysate concentration was 0.07 microg/mL; PD clearance was 0.06 L/hr. Azithromycin is not substantially removed by CAPD in the absence of peritonitis and cannot be recommended for widespread use in this setting at present. However, the successful use of azithromycin in CAPD peritonitis, due possibly to an intracellular drug transport mechanism, has been reported. Future research should address this possibility.
Moloi, Mothusi Walter; Kajawo, Shepherd; Noubiap, Jean Jacques; Mbah, Ikechukwu O; Ekrikpo, Udeme; Kengne, Andre Pascal; Bello, Aminu K; Okpechi, Ikechi G
2018-05-24
Continuous ambulatory peritoneal dialysis (CAPD) is the ideal modality for renal replacement therapy in most African settings given that it is relatively cheaper than haemodialysis (HD) and does not require in-centre care. CAPD is, however, not readily utilised as it is often complicated by peritonitis leading to high rates of technique failure. The objective of this study is to assess the prevalence of CAPD-related peritonitis and all-cause mortality in patients treated with CAPD in Africa. We will search PubMed, EMBASE, SCOPUS, Africa Journal Online and Google Scholar for studies conducted in Africa from 1 January 1980 to 30 June 2017 with no language restrictions. Eligible studies will include cross-sectional, prospective observational and cohort studies of patients treated with CAPD. Two authors will independently screen, select studies, extract data and conduct risk of bias assessment. Data consistently reported across studies will be pooled using random-effects meta-analysis. Heterogeneity will be evaluated using Cochrane's Q statistic and quantified using I 2 statistics. Graphical and formal statistical tests will be used to assess for publication bias. Ethical approval will not be needed for this study as data used will be extracted from already published studies. Results of this review will be published in a peer-reviewed journal and presented at conferences. The Preferred Reporting Items for Systematic reviews and Meta-Analyses for Protocols 2015 (PRISMA-P 2015) framework guided the development of this protocol. CRD42017072966. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
2014-01-01
In a prospective randomized controlled study, the efficacy and safety of a continuous ambulatory peritoneal dialysis (CAPD) technique has been evaluated using one icodextrin-containing and two glucose-containing dialysates a day. Eighty incident CAPD patients were randomized to two groups; GLU group continuously using four glucose-containing dialysates (n=39) and ICO group using one icodextrin-containing and two glucose-containing dialysates (n=41). Variables related to residual renal function (RRF), metabolic and fluid control, dialysis adequacy, and dialysate effluent cancer antigen 125 (CA125) and interleukin 6 (IL-6) levels were measured. The GLU group showed a significant decrease in mean renal urea and creatinine clearance (-Δ1.2±2.9 mL/min/1.73 m2, P=0.027) and urine volume (-Δ363.6±543.0 mL/day, P=0.001) during 12 months, but the ICO group did not (-Δ0.5±2.7 mL/min/1.73 m2, P=0.266; -Δ108.6±543.3 mL/day, P=0.246). Peritoneal glucose absorption and dialysate calorie load were significantly lower in the ICO group than the GLU group. The dialysate CA125 and IL-6 levels were significantly higher in the ICO group than the GLU group. Dialysis adequacy, β2-microglobulin clearance and blood pressure did not differ between the two groups. The CAPD technique using one icodextrin-containing and two glucose-containing dialysates tends to better preserve RRF and is more biocompatible, with similar dialysis adequacy compared to that using four glucose-containing dialysates in incident CAPD patients. [Clincal Trial Registry, ISRCTN23727549] Graphical Abstract PMID:25246739
Rangel, Uesliz Vianna; Gomes, Saint Clair dos Santos; Costa, Ana Maria Aranha Magalhães; Moreira, Maria Elisabeth Lopes
2014-01-01
OBJECTIVE: to relate the variables from a surveillance form for intravenous devices in high risk newborn infants with peripherally inserted central catheter related infection. METHODOLOGY: approximately 15 variables were studied, being associated with peripherally inserted central catheter related infection, this being defined by blood culture results. The variables analyzed were obtained from the surveillance forms used with intravenous devices, attached to the medical records of newborn infants weighing between 500 and 1,499 g. The statistical association was defined using the Chi-squared and Student t tests. The study was approved by the Research Ethics Committee of the Instituto Fernandes Figueira under process N. 140.703/12. RESULTS: 63 medical records were analyzed. The infection rate observed was 25.4%. Of the variables analyzed, only three had a statistically-significant relationship with the blood culture - the use of drugs capable of inhibiting acid secretion, post-natal steroid use, and undertaking more than one invasive procedure (p-value of 0.0141, 0.0472 and 0.0277, respectively). CONCLUSION: the absence of significance of the variables of the form may be related to the quality of the records and to the absence of standardization. It is recommended that the teams be encouraged to adhere to the protocol and fill out the form. PMID:25493681
Infusion phlebitis in post-operative patients: when and why.
Monreal, M; Oller, B; Rodriguez, N; Vega, J; Torres, T; Valero, P; Mach, G; Ruiz, A E; Roca, J
1999-01-01
The most common complication of intravenous therapy is infusion phlebitis. This study was done to prospectively assess its frequency in a series of consecutive patients who will undergo surgery, and to identify which variables may predict an increased risk for phlebitis. 400 consecutive patients who will undergo surgery in a general surgery department were included. Only the first catheter, inserted the day before surgery, was taken into account. Eighteen variables (from the infusion, the catheter and from the patient) were prospectively evaluated for their contribution to the occurrence of phlebitis. 60/400 patients (15%) developed phlebitis, and most of them needed insertion of a further catheter. The univariate analysis showed that patients who developed phlebitis were older, and their pre-operative levels of both blood haemoglobin and neutrophil cound were significantly higher than those in patients who did not develop phlebitis. However, the multivariate analysis only confirmed the association with blood haemoglobin levels: the risk of phlebitis sharply increased in the patients with the highest haemoglobin levels. As to the influence of time on phlebitis development, there was a significant decrease in the day-specific risk, from the 5th day on. In our series, blood haemoglobin levels were found to be the only variable associated to a higher risk of phlebitis. Besides, in contrast with the recommendations by the Centers for Disease Control, no significant increase in the day-specific risk of phlebitis was found. Thus, a guideline to select the type of catheter to be inserted in an individual patient is suggested. Copyright 2000 S. Karger AG, Basel
The dangers of long-term catheter drainage.
Lowthian, P
There are many dangers associated with long-term urinary bladder drainage by catheter. For various reasons, the choice of catheter is important, and its initial insertion can be particularly hazardous. All catheterizations should, however, be safer when there is some urine (or other fluid) in the bladder. The appropriate choice of drainage system attached to the catheter can delay bacterial invasion of the bladder. Great care is needed to prevent blockage of the system, particularly when bacteriuria is present. Recent evidence indicates that some bacteria encourage the development of encrustations, so that, in some circumstances, catheters may become blocked within 24 hours. This, together with other considerations, strongly suggests that indwelling catheters should be changed at intervals of not more than 5 days. The practical implications of this are considered, as are the benefits that may accrue. Accidental catheter traction is another danger, and some possible methods of avoiding this are discussed. Finally, the need for a new kind of drainage-bag support is highlighted.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Eu Hyun, E-mail: doorihyun6@gmail.com; Oh, Jung Suk; Chun, Ho Jong
PurposeThe study aimed to introduce a monorail technique to overcome difficult anatomical course via left internal jugular vein in implantable port insertion.MethodsFrom 2007 to 2016, a total of 9346 patients were referred for implantable port insertion in our interventional unit, among which 79 cases were requested to insert on the left side. Our monorail technique was applied only when the technical challenge of the catheter tip entering the azygos vein instead of the superior vena cava occurred (n = 7). The technique consists of puncturing at the distal tip of the port catheter with a 21-gauge micropuncture needle and advancing a 0.018-in.more » hair-wire to guide and provide support for pre-assembled port.ResultsThe monorail technique was performed in seven patients and all but one case were technically successful, showing a technical success rate of 85.7%. There were no immediate or delayed complications.ConclusionsThe monorail technique is helpful to overcome the difficult anatomical course via left internal jugular vein in implantable port insertion.« less
Glover, Kevin R; Stahl, Brian R; Murray, Connie; LeClair, Matthew; Gallucci, Susan; King, Mary Anne; Labrozzi, Laura J; Schuster, Catherine; Keleekai, Nowai L
2017-09-01
Despite peripheral intravenous catheter (PIVC) insertion being a commonly performed skill, practicing nurses may receive little substantive education, training, or opportunities to practice this skill at a competent level. This article describes a collaboration between private industry and a hospital to modify, implement, and evaluate a simulation-based blended PIVC insertion continuing education program for staff nurses. Included is an overview of the practical and theoretical rationale for the initial development of the curriculum to address an identified PIVC insertion education gap, the collaborative modification and implementation of the program, and an evaluation of the program. The curriculum combined self-paced e-learning and classroom-based deliberate practice with simulation tools of varying fidelity in a peer-to-peer learning environment. Given the mutual challenges of resource allocation in industry training and clinical nursing education departments, interprofessional partnerships may be an effective option for sharing instructional knowledge and resources to promote innovation and improve patient care. J Contin Educ Nurs. 2017;48(9):397-406. Copyright 2017, SLACK Incorporated.
Kim, Eu Hyun; Oh, Jung Suk; Chun, Ho Jong; Lee, Hae Giu; Choi, Byung Gil
2017-03-01
The study aimed to introduce a monorail technique to overcome difficult anatomical course via left internal jugular vein in implantable port insertion. From 2007 to 2016, a total of 9346 patients were referred for implantable port insertion in our interventional unit, among which 79 cases were requested to insert on the left side. Our monorail technique was applied only when the technical challenge of the catheter tip entering the azygos vein instead of the superior vena cava occurred (n = 7). The technique consists of puncturing at the distal tip of the port catheter with a 21-gauge micropuncture needle and advancing a 0.018-in. hair-wire to guide and provide support for pre-assembled port. The monorail technique was performed in seven patients and all but one case were technically successful, showing a technical success rate of 85.7%. There were no immediate or delayed complications. The monorail technique is helpful to overcome the difficult anatomical course via left internal jugular vein in implantable port insertion.
Arvaniti, Kostoula; Lathyris, Dimitrios; Blot, Stijn; Apostolidou-Kiouti, Fani; Koulenti, Despoina; Haidich, Anna-Bettina
2017-04-01
Selection of central venous catheter insertion site in ICU patients could help reduce catheter-related infections. Although subclavian was considered the most appropriate site, its preferential use in ICU patients is not generalized and questioned by contradicted meta-analysis results. In addition, conflicting data exist on alternative site selection whenever subclavian is contraindicated. To compare catheter-related bloodstream infection and colonization risk between the three sites (subclavian, internal jugular, and femoral) in adult ICU patients. We searched MEDLINE, EMBASE, Cochrane Central Register of Controlled trials, CINAHL, and ClinicalTrials.gov. Eligible studies were randomized controlled trials and observational ones. Extracted data were analyzed by pairwise and network meta-analysis. Twenty studies were included; 11 were observational, seven were randomized controlled trials for other outcomes, and two were randomized controlled trials for sites. We evaluated 18,554 central venous catheters: 9,331 from observational studies, 5,482 from randomized controlled trials for other outcomes, and 3,741 from randomized controlled trials for sites. Colonization risk was higher for internal jugular (relative risk, 2.25 [95% CI, 1.84-2.75]; I = 0%) and femoral (relative risk, 2.92 [95% CI, 2.11-4.04]; I = 24%), compared with subclavian. Catheter-related bloodstream infection risk was comparable for internal jugular and subclavian, higher for femoral than subclavian (relative risk, 2.44 [95% CI, 1.25-4.75]; I = 61%), and lower for internal jugular than femoral (relative risk, 0.55 [95% CI, 0.34-0.89]; I = 61%). When observational studies that did not control for baseline characteristics were excluded, catheter-related bloodstream infection risk was comparable between the sites. In ICU patients, internal jugular and subclavian may, similarly, decrease catheter-related bloodstream infection risk, when compared with femoral. Subclavian could be suggested as the most appropriate site, whenever colonization risk is considered and not, otherwise, contraindicated. Current evidence on catheter-related bloodstream infection femoral risk, compared with the other sites, is inconclusive.
Applicability of central auditory processing disorder models.
Jutras, Benoît; Loubert, Monique; Dupuis, Jean-Luc; Marcoux, Caroline; Dumont, Véronique; Baril, Michèle
2007-12-01
Central auditory processing disorder ([C]APD) is a relatively recent construct that has given rise to 2 theoretical models: the Buffalo Model and the Bellis/Ferre Model. These models describe 4 and 5 (C)APD categories, respectively. The present study examines the applicability of these models to clinical practice. Neither of these models was based on data from peer-reviewed sources. This is a retrospective study that reviewed 178 records of children diagnosed with (C)APD, of which 48 were retained for analysis. More than 80% of the children could be classified into one of the Buffalo Model categories, while more than 90% remained unclassified under the Bellis/Ferre Model. This discrepancy can be explained by the fact that the classification of the Buffalo Model is based primarily on a single central auditory test (Staggered Spondaic Word), whereas the Bellis/Ferre Model classification uses a combination of auditory test results. The 2 models provide a conceptual framework for (C)APD, but they must be further refined to be fully applicable in clinical settings.
Clark, David J; Chakraborty, Aabir; Roebuck, Derek J; Thompson, Dominic N P
2016-07-01
Ventriculoatrial (VA) shunts are commonly used as a second-line treatment of hydrocephalus when the peritoneum is an unsuitable site for the distal catheter. Many centres now utilise ultrasound and interventional radiology techniques to aid placement of the distal catheter. The purpose of this study was to conduct a contemporary audit of VA shunting in children using interventional radiology techniques for placement of the distal catheter. A retrospective analysis of all patients who had VA shunts inserted between June 2000 and June 2010 was conducted using a prospectively updated surgical database and case notes review. Ninety-four VA shunts were inserted in 38 patients. Thirty-seven patients had been treated initially with ventriculoperitoneal (VP) shunts. Twenty-two patients required at least 1 shunt revision (58 %). The 6-month, 1- and 2-year shunt survival rates were 53, 43 and 27 %, respectively. Blockage was the commonest reason for shunt failure (68 %). The site of failure was proximal (ventricular catheter +/- valve) in 32 % and distal (atrial catheter) in 21 % of cases. The overall infection rate was 6 % per procedure and 11 % per patient. There were 7 deaths, of which 3 were shunt related. VA shunting provides a viable second-line option for shunt placement in complex hydrocephalus. The causes of shunt failure (blockage, infection and equipment failure) are similar to VP shunting though shunt survival rates are inferior to VP shunts. Ultrasound guided VA shunt placement provides a relatively safe, second-line alternative to the placement of a ventriculoperitoneal shunt when this route is unsuitable.
Bolcato, Matteo; Russo, Marianna; Donadello, Damiano; Rodriguez, Daniele; Aprile, Anna
2017-01-01
Patient: Female, newborn Final Diagnosis: Loss of falange of the hand Symptoms: Manual disability • Pain Medication: Ampicilline Clinical Procedure: Insert vascular catheter Specialty: Forenscic Medicine Objective: Rare disease Background: The positioning of peripheral venous catheters (PVC) is an invasive procedure commonly performed in pediatrics hospital wards to obtain vascular access for the administration of fluids, medications and other intravenous (IV) therapies. Many studies exist about management of peripheral venous access in adults. On the contrary, scientific evidence on the management of this procedure in children and newborns, especially regarding the optimal duration of infusion and the possible related side effects, is still poor. To minimize the risk of phlebitis, the guidelines of the US Centers for Disease Control and Prevention suggest the replacement of the catheter every 72–96 hours in adult patients, while in pediatric patients the catheter can remain in place for the entire duration of the IV therapy, unless complications arise. Case Report: In the presented case, after the positioning of a PVC in a newborn, no clear signs/symptoms of phlebitis were registered before the sixth day and, despite the immediate removal of the catheter, the thrombotic process, secondary to phlebitis, was already occurring, causing serious and permanent disabling outcomes, susceptible to legal medical evaluation and financial compensation. Conclusions: The knowledge of this case is particularly interesting to clinicians working in the field of neonatal care and to clinical risk management services inside hospital structures, since similar cases may be the source of requests for extremely high financial compensations due to medical liability. PMID:29056746
Ronen, Ohad; Shlomo, Fanny; Ben-Adiva, Gila; Edri, Zehava; Shema-Didi, Lilach
2017-10-01
The use of intravascular catheters is often complicated by phlebitis, which is associated with increased morbidity and extended duration of hospitalization. We conducted a study to investigate the impact of needleless intravenous access devices on the rate of phlebitis in peripheral venous catheters (PVCs). We prospectively recruited patients in 2 phases. The first group was treated with a regular cap, and the second group was treated with a needleless connector. The incidence of catheter-related phlebitis (CRP) was recorded as the primary end point. A total of 620 PVCs using regular caps were inserted into 340 patients and CRP rates were recorded. In the second phase of the study, 169 PVCs using needleless connectors were inserted into 135 patients. In the group treated with the regular cap, the CRP rate was 60% compared with 7% in the group treated with the needleless cap (P <.001). Consequently, the number of catheter replacements was decreased from 1.9 on average to 1.3 (P <.001). In both phases, patients who developed phlebitis had a statistically significant longer mean hospitalization period (P <.001), as were patients in the regular cap group (P <.01). The use of needleless connectors was found to be associated with a significant reduction of CRP in peripheral veins in a surgery department setting. The decreased morbidity resulted in a lower number of catheter replacements and duration of hospitalization. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Patel, Premal Amrishkumar; Parra, Dimitri A; Bath, Ramnik; Amaral, Joao G; Temple, Michael J; John, Philip R; Connolly, Bairbre L
2016-06-01
To identify factors associated with adherence of implanted venous access port catheters in children and describe technical strategies for removing "stuck" ports. A retrospective single-center review of port removals was conducted between 2003 and 2012. Cases were identified through radiology reports. Clinical details (eg, demographics, disease, port dwell time, interventional techniques) were obtained through patient charts. Cases were classified as difficult removals if there was documented adherence to soft tissues or vein, or simple removals if no difficulty was recorded. Difficult removals were categorized and graded on increasing invasiveness of techniques required. Successful removal was defined as complete removal of the port catheter. Difficult removals were compared with simple removals for factors associated with difficult removal. Of all removals (N = 1,306), 58 were classified as difficult removals (4%). Using various techniques, 57 of 58 (98%) adherent port catheters were successfully removed. Factors identified with difficult removals included primary diagnosis of acute lymphoblastic leukemia (ALL) (78% vs 37%, P < .0001), age at insertion (3.7 y vs 5.4 y, P = .0019), and port dwell time (median 1,087 d vs 616 d, P < .0001). Difficulty removing port catheters in children is uncommon. Port catheters can usually be removed successfully using various IR techniques ranging in invasiveness. There is an association of difficult removal with early age at insertion, ALL diagnosis, and long port dwell time. Awareness of these factors may help physicians inform parents of potential difficulties and plan the removal procedure. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.
Lyons, Margaret G; Phalen, Ann G
2014-01-01
Research has failed to demonstrate an optimal flushing solution or frequency for central catheters. In a 2002 study of 50 000 home care patients, catheter dysfunction with loss of patency was the most common complication and occurred in 29% of the peripherally inserted central catheters (PICCs) tracked. With the advent of the Affordable Care Act and the promise of expanded home care services, this study offers evidence as to a preferred flushing protocol to prevent catheter patency complications for home infusion patients with PICCs. This prospective, randomized, 1-way, single-blinded posttest with control group study was performed to compare 3 commonly used flushing protocols in home infusion patients with PICCs. The independent variable was the flushing protocol, and dependent variables included the development of patency-related complications and other significant issues such as sluggishness, occlusion, missed medication doses, catheter replacement, additional nursing visits, and the use of alteplase (Cathflo Activase). Each of the study groups had patients who experienced 1 or more patency-related complications. Additional factors that may affect catheter function, including patient age, gender, diagnosis, therapy type, frequency of catheter use, catheter brand/size/number of lumens, concomitant use of anticoagulant medications, and whether PICCs were used for routine lab testing, were analyzed, and no statistical significance was determined. Catheter dwell time (catheter days) was statistically significant (p = .003, confidence interval = 95%; assuming equal variance) and confirmed the assumption that the longer a home care patient's catheter was in place, the more complications occurred. There were no cases of heparin allergy, heparin-induced thrombocytopenia, or line infection. The data provide some evidence to support the elimination of heparin flushing in home care patients with PICCs, although data in the saline-only group that related to additional registered nurse visits to assess PICC patency and the use of alteplase (Cathflo Activase) were trending toward significance because this group experienced a higher incidence of these complications than both the heparin groups. These findings should not be translated to home care patients with cancer or pregnancy diagnoses because these populations were excluded from this study. More studies of this topic area should be initiated. Please see video abstract, Supplemental Digital Content 1, for more information (http://links.lww.com/JIN/A3).
Griffin, Andrew S; Gage, Shawn M; Lawson, Jeffrey H; Kim, Charles Y
2017-01-01
This study evaluated whether the use of a staged Hemodialysis Reliable Outflow (HeRO; Merit Medical, South Jordan, Utah) implantation strategy incurs increased early infection risk compared with conventional primary HeRO implantation. A retrospective review was performed of 192 hemodialysis patients who underwent HeRO graft implantation: 105 patients underwent primary HeRO implantation in the operating room, and 87 underwent a staged implantation where a previously inserted tunneled central venous catheter was used for guidewire access for the venous outflow component. Within the staged implantation group, 32 were performed via an existing tunneled hemodialysis catheter (incidentally staged), and 55 were performed via a tunneled catheter inserted across a central venous occlusion in an interventional radiology suite specifically for HeRO implantation (intentionally staged). Early infection was defined as episodes of bacteremia or HeRO infection requiring resection ≤30 days of HeRO implantation. For staged HeRO implantations, the median interval between tunneled catheter insertion and conversion to a HeRO graft was 42 days. The overall HeRO-related infection rate ≤30 days of implantation was 8.6% for primary HeRO implantation and 2.3% for staged implantations (P = .12). The rates of early bacteremia and HeRO resection requiring surgical resection were not significantly different between groups (P = .19 and P = .065, respectively), nor were age, gender, laterality, anastomosis to an existing arteriovenous access, human immunodeficiency virus status, diabetes, steroids, chemotherapy, body mass index, or graft location. None of the patient variables, techniques, or graft-related variables correlated significantly with the early infection rate. The staged HeRO implantation strategy did not result in an increased early infection risk compared with conventional primary implantation and is thus a reasonable strategy for HeRO insertion in hemodialysis patients with complex central venous disease. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
US Army Institute of Surgical Research Annual Research Progress Report for Fiscal Year 1987.
1987-10-01
oases, respiratory rate, chest roentgenograms), cardiovascular (blood pressure, central venous pressure, cardiac output), and renal (urine output, urine...Monitoring includes the precordial and/or esophageal stethoscope, peripheral pulse, blood pressure, central venous pressure, Swan-Ganz catheter... central venous , peripheral venous , and Swan-Ganz (7F, American Edward Laboratories, Irvine CA) catheters and an esophageal balloon were inserted. After a 2
Arterial catheter complications and management problems: observations from AACN's Thunder Project.
1993-09-01
Arterial cannulation, while common in critical care, is a procedure with attendant risks of complications. Anecdotal data from the American Association of Critical Care Nurses' Thunder Project provided evidence that catheters, insertion sites, and monitoring systems continue to be sources of complications. The problems have not changed since arterial cannulation began. Line management issues cannot be resolved until low-maintenance systems are developed.
Peripheral Venous Access Ports: Outcomes Analysis in 109 Patients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bodner, Leonard J.; Nosher, John L.; Patel, Kaushik M.
Purpose: To perform a retrospective outcomes analysis of central venous catheters with peripheral venous access ports, with comparison to published data.Methods: One hundred and twelve central venous catheters with peripherally placed access ports were placed under sonographic guidance in 109 patients over a 4-year period. Ports were placed for the administration of chemotherapy, hyperalimentation, long-term antibiotic therapy, gamma-globulin therapy, and frequent blood sampling. A vein in the upper arm was accessed in each case and the catheter was passed to the superior vena cava or right atrium. Povidone iodine skin preparation was used in the first 65 port insertions. Amore » combination of Iodophor solution and povidone iodine solution was used in the last 47 port insertions. Forty patients received low-dose (1 mg) warfarin sodium beginning the day after port insertion. Three patients received higher doses of warfarin sodium for preexistent venous thrombosis. Catheter performance and complications were assessed and compared with published data.Results: Access into the basilic or brachial veins was obtained in all cases. Ports remained functional for a total of 28,936 patient days. The port functioned in 50% of patients until completion of therapy, or the patient's expiration. Ports were removed prior to completion of therapy in 18% of patients. Eleven patients (9.9% of ports placed) suffered an infectious complication (0.38 per thousand catheter-days)-in nine, at the port implantation site, in two along the catheter. In all 11 instances the port was removed. Port pocket infection in the early postoperative period occurred in three patients (4.7%) receiving a Betadine prep vs two patients (4.2%) receiving a standard O.R. prep. This difference was not statistically significant (p = 0.9). Venous thrombosis occurred in three patients (6.8%) receiving warfarin sodium and in two patients (3%) not receiving warfarin sodium. This difference was not statistically significant (p = 0.6). Aspiration occlusion occurred in 13 patients (11.7%). Intracatheter urokinase was infused in eight of these patients and successfully restored catheter function in all but two instances. These complication rates are comparable to or better than those reported with chest ports.Conclusion: Peripheral ports for long-term central venous access placed by interventional radiologists in the interventional radiology suite are as safe and as effective as chest ports.« less
Evaluation of an active magnetic resonance tracking system for interstitial brachytherapy.
Wang, Wei; Viswanathan, Akila N; Damato, Antonio L; Chen, Yue; Tse, Zion; Pan, Li; Tokuda, Junichi; Seethamraju, Ravi T; Dumoulin, Charles L; Schmidt, Ehud J; Cormack, Robert A
2015-12-01
In gynecologic cancers, magnetic resonance (MR) imaging is the modality of choice for visualizing tumors and their surroundings because of superior soft-tissue contrast. Real-time MR guidance of catheter placement in interstitial brachytherapy facilitates target coverage, and would be further improved by providing intraprocedural estimates of dosimetric coverage. A major obstacle to intraprocedural dosimetry is the time needed for catheter trajectory reconstruction. Herein the authors evaluate an active MR tracking (MRTR) system which provides rapid catheter tip localization and trajectory reconstruction. The authors assess the reliability and spatial accuracy of the MRTR system in comparison to standard catheter digitization using magnetic resonance imaging (MRI) and CT. The MRTR system includes a stylet with microcoils mounted on its shaft, which can be inserted into brachytherapy catheters and tracked by a dedicated MRTR sequence. Catheter tip localization errors of the MRTR system and their dependence on catheter locations and orientation inside the MR scanner were quantified with a water phantom. The distances between the tracked tip positions of the MRTR stylet and the predefined ground-truth tip positions were calculated for measurements performed at seven locations and with nine orientations. To evaluate catheter trajectory reconstruction, fifteen brachytherapy catheters were placed into a gel phantom with an embedded catheter fixation framework, with parallel or crossed paths. The MRTR stylet was then inserted sequentially into each catheter. During the removal of the MRTR stylet from within each catheter, a MRTR measurement was performed at 40 Hz to acquire the instantaneous stylet tip position, resulting in a series of three-dimensional (3D) positions along the catheter's trajectory. A 3D polynomial curve was fit to the tracked positions for each catheter, and equally spaced dwell points were then generated along the curve. High-resolution 3D MRI of the phantom was performed followed by catheter digitization based on the catheter's imaging artifacts. The catheter trajectory error was characterized in terms of the mean distance between corresponding dwell points in MRTR-generated catheter trajectory and MRI-based catheter digitization. The MRTR-based catheter trajectory reconstruction process was also performed on three gynecologic cancer patients, and then compared with catheter digitization based on MRI and CT. The catheter tip localization error increased as the MRTR stylet moved further off-center and as the stylet's orientation deviated from the main magnetic field direction. Fifteen catheters' trajectories were reconstructed by MRTR. Compared with MRI-based digitization, the mean 3D error of MRTR-generated trajectories was 1.5 ± 0.5 mm with an in-plane error of 0.7 ± 0.2 mm and a tip error of 1.7 ± 0.5 mm. MRTR resolved ambiguity in catheter assignment due to crossed catheter paths, which is a common problem in image-based catheter digitization. In the patient studies, the MRTR-generated catheter trajectory was consistent with digitization based on both MRI and CT. The MRTR system provides accurate catheter tip localization and trajectory reconstruction in the MR environment. Relative to the image-based methods, it improves the speed, safety, and reliability of the catheter trajectory reconstruction in interstitial brachytherapy. MRTR may enable in-procedural dosimetric evaluation of implant target coverage.
Use of laparoscopy in the management of malfunctioning peritoneal dialysis catheters.
Brandt, C P; Ricanati, E S
1996-01-01
The proper function of peritoneal dialysis (PD) catheters can be compromised by catheter malposition, fibrin clot, or omental wrapping. The purpose of this study was to determine the efficacy of laparoscopy in the treatment of malfunctioning PD catheters. All patients undergoing laparoscopy for catheter dysfunction at MetroHealth Medical Center in Cleveland, Ohio, from 1991 to 1995, were reviewed. Twenty-six laparoscopies were performed in 22 patients, for malfunction occurring an average of 3.9 months following insertion (range 0.5-18 months). Omental and/or small below wrapping as present in all but three cases. Lysis of adhesions was required in 19 of 26 cases, with repositioning only in seven. Eight patients had failed attempts at stiff wire manipulation prior to laparoscopy. Perioperative complications occurred in seven cases, consisting of temporary dialysate leakage (2), enterotomy (1), and early reocclusion (4). Repeat laparoscopy was successful in three of these four reocclusions. The overall success rate (catheter function > 30 days after laparoscopy) was 21/22 (96%). Laparoscopy is highly accurate and effective in the management of peritoneal dialysis catheter dysfunction and results in prolongation of catheter life.
[Evaluation of the efficacy and safety of Foley catheter pre-induction of labor].
Jagielska, Iwona; Kazdepka-Ziemińska, Anita; Janicki, Radosław; Fórmaniak, Jacek; Walentowicz-Sadłecka, Małgorzata; Grabiec, Marek
2013-03-01
Labor induction is being increasingly used (15-30% of pregnancies). The most common indications include late pregnancy preeclampsia, intrauterine fetal growth retardation (IUGR), hypertension. Preinduction by speeding up the ripening of the cervix increases the chances of successful induction. There are mechanical and pharmacological methods of pre-induction: the Foley catheter hygroscopic dilators, prostaglandin gel, misoprostol. There are various schemes of labor pre-induction and the differences relate primarily to duration of catheter time, amniotomy or the start of the oxytocin. Numerous studies on pre-induction and induction of labor aimed to compare the efficacy of these different methods. The effectiveness of the Foley catheter is usually assessed by comparing cervical maturity (Bishop score) and ripening of the cervix, evaluated in centimeters, before and after removing the cathetec time to labor since pre-induction and the number of births. In order to select the appropriate method, its safety for the mother and the fetus/newborn needs to be assessed. According to most authors, the use of a Foley catheter does not cause over-stimulation of the uterus, does not increase the risk of rupture or intrauterine infection, and does not adversely affect the fetus and newborn. To assess the efficacy and safety of labor pre-induction using a Foley catheter The study included 109 women hospitalized between 03.01.2011 and 11.30.2011, who underwent labor pre-induction with a Foley catheter The inclusion criteria were: one fetal pregnancy longitudinal cephalic fetal position, completed 36 weeks of pregnancy fetal bladder preserved, Bishop score < 5 points. The exclusion criteria were: placenta previa, uterine infection, unexplained bleeding, abnormal fetal heart rate, and other reasons preventing vaginal delivery such as fetal weight above 4500 g. Vaginal swabs for the presence of Streptococcus agalactiae (GBS) were obtained from each patient. In case of a positive result perinatal antibiotic prophylaxis was administered before insertion of the catheter The study group was divided into two subgroups according to parity: primiparous and multiparous. Indications for induction, method of pregnancy termination, the pregnancy and its complications were evaluated. The condition of the newborns was evaluated using the Apgar score, cord blood pH and infant birth weight. We analyzed cervical ripeness (Bishop score) before the insertion and after the removal of the catheter and serum C-reactive protein (CRP) before and 20 hours after insertion. CRP was not studied in pregnant women diagnosed with GBS colonization. The results were compared between the subgroups. An increase in the Bishop score to> 5 and delivery within 12 hours since the planned removal of the catheter regardless of the method of pregnancy and the use of oxytocin, was considered as successful induction of labor Catheter pre-induction was performed in 109 pregnant women, what amounted to 7.87% all of deliveries in our department during the analyzed period. Mean patient age was 29.3 +/- 5.35 years, mean duration of pregnancy 40 weeks of gestation (+/- 1 week 5 days), and primiparas constituted 66.06% of all cases. The most common indication for labor induction was post-term pregnancy (55.05%), hypertension and preeclampsia (16.51%). The following complications were observed in the study group after insertion of the catheter: 8 (7.34%) cases of premature rupture of the membranes (PROM), but none of them occurred in the process of inserting the catheter 11 (10.09%) women had the catheter removed (patients request) due to pain and the feeling of discomfort before the scheduled time, 2 (1.84%) cases of bleeding (in the first case the cesarean section was performed and the baby was born in a good overall condition, in the second case the bleeding subsided spontaneously). There was a statistically significant increase in the Bishop score for the entire study group and in the two subgroups. Mean increase in the Bishop score was 2.68 +/- 1.39 points for the entire cohort (p < 0.005). The rate of successful pre-induction resulting in a delivery was 69.4%, with vaginal births accounting for 66.67% of all cases. Also, 30.66% of the pregnant women did not require the use of oxytocin. The most common indication for cesarean section was threatening intrauterine fetal asphyxia. Higher efficiency of pre-induction was found in the multiparous group. The observed increase in CRP (p < 0.005) was within the normal range for pregnant women (< 12 mg/I). None of the patients showed any clinical signs of infection. Mean birth weight of the infants was 3392 +/- 644.72 g, mean Apgar score was 9.5 +/- 0.80 and mean cord blood pH was 7.3 +/- 0.08. The Foley catheter is an effective method of inducing cervical maturation. The Foley catheter is safe method of labor induction for the mother fetus and newborn.
Raad, Issam; Hachem, Ray; Tcholakian, Robert K.; Sherertz, Robert
2002-01-01
To determine the efficacy of antibiotic catheter lock solution in preventing catheter-related infections, silicone catheters were tunneled and inserted into the jugular veins of 18 rabbits. The catheters were challenged with an intraluminal injection of 105 CFU of slime-producing Staphylococcus epidermidis in 0.1 ml of water. The catheters were maintained on heparin (100 IU/ml) flush for the first 3 days. On day 3, quantitative blood samples for culture were obtained from the catheters and ear veins, which documented catheter-related bacteremia, and the rabbits were randomized to have their catheters flushed as follows: five animals were continued on heparin (100 IU/ml), five animals received vancomycin (3 mg/ml) with heparin (100 IU/ml), and eight animals received 3 mg of minocycline per ml with 30 mg of EDTA per ml (M-EDTA). All animals were killed at day 7. Blood, catheters, jugular veins, and heart valves were cultured quantitatively. Animals maintained on heparin developed catheter-related colonization, bacteremia, septic phlebitis, and endocarditis. Vancomycin-heparin partially prevented catheter colonization, bacteremia, and phlebitis (P = 0.2). M-EDTA completely prevented catheter colonization, catheter-related bacteremia, and phlebitis in all of the animals (P < 0.01). Tricuspid endocarditis was equally prevented by vancomycin-heparin and M-EDTA (P ≤ 0.06). In conclusion, the M-EDTA catheter flush solution was highly efficacious in preventing catheter-related colonization, bacteremia, septic phlebitis, and endocarditis in rabbits. PMID:11796338
Tamura, Tetsuo; Nakamura, Hiroshi; Sato, Say; Seki, Makoto; Nishiki, Hideto
2014-06-01
This study proposed a modified procedure, using a small balloon catheter (SB catheter, 45 ml), for reducing bladder damage in cows. Holstein cows and the following catheters were prepared: smaller balloon catheter (XSB catheter; 30 ml), SB catheter and standard balloon catheter (NB catheter; 70 ml, as the commonly used, standard size). In experiment 1, each cow was catheterized. The occurrence of catheter-associated hematuria (greater than 50 RBC/HPF) was lower in the SB catheter group (0.0%, n=7) than in the NB catheter group (71.4%, n=7; P<0.05). In experiment 2, general veterinary parameters, urine pH, body temperature and blood values in cows were not affected before or after insertion of SB catheters (n=6). The incidence of urinary tract infection (UTI) was 3.0% per catheterized day (n=22). In experiment 3, feeding profiles, daily excretion of urinary nitrogen (P<0.05) and rate from nitrogen intake in urine (P<0.01), were higher with use of the SB catheter (n=13) than with the use of the vulva urine cup (n=18), indicating that using the SB catheter can provide accurate nutritional data. From this study, we concluded that when using an SB catheter, the following results occur; reduction in bladder damage without any veterinary risks and accuracy in regard to feeding parameters, suggesting this modified procedure using an SB catheter is a useful means of daily urine collection.
TAMURA, Tetsuo; NAKAMURA, Hiroshi; SATO, Say; SEKI, Makoto; NISHIKI, Hideto
2014-01-01
ABSTRACT This study proposed a modified procedure, using a small balloon catheter (SB catheter, 45 ml), for reducing bladder damage in cows. Holstein cows and the following catheters were prepared: smaller balloon catheter (XSB catheter; 30 ml), SB catheter and standard balloon catheter (NB catheter; 70 ml, as the commonly used, standard size). In experiment 1, each cow was catheterized. The occurrence of catheter-associated hematuria (greater than 50 RBC/HPF) was lower in the SB catheter group (0.0%, n=7) than in the NB catheter group (71.4%, n=7; P<0.05). In experiment 2, general veterinary parameters, urine pH, body temperature and blood values in cows were not affected before or after insertion of SB catheters (n=6). The incidence of urinary tract infection (UTI) was 3.0% per catheterized day (n=22). In experiment 3, feeding profiles, daily excretion of urinary nitrogen (P<0.05) and rate from nitrogen intake in urine (P<0.01), were higher with use of the SB catheter (n=13) than with the use of the vulva urine cup (n=18), indicating that using the SB catheter can provide accurate nutritional data. From this study, we concluded that when using an SB catheter, the following results occur; reduction in bladder damage without any veterinary risks and accuracy in regard to feeding parameters, suggesting this modified procedure using an SB catheter is a useful means of daily urine collection. PMID:24561376
[Peripheral intravenous catheter-related phlebitis].
van der Sar-van der Brugge, Simone; Posthuma, E F M Ward
2011-01-01
Phlebitis is a very common complication of the use of intravenous catheters. Two patients with an i.v. catheter complicated by thrombophlebitis are described. Patient A was immunocompromised due to chronic lymphatic leukaemia and developed septic thrombophlebitis with positive blood cultures for S. Aureus. Patient B was being treated with flucloxacillin because of an S. Aureus infection and developed chemical phlebitis. Septic phlebitis is rare, but potentially serious. Chemical or mechanical types of thrombophlebitis are usually less severe, but happen very frequently. Risk factors include: female sex, previous episode of phlebitis, insertion at (ventral) forearm, emergency placement and administration of antibiotics. Until recently, routine replacement of peripheral intravenous catheters after 72-96 h was recommended, but randomised controlled trials have not shown any benefit of this routine. A recent Cochrane Review recommends replacement of peripheral intravenous catheters when clinically indicated only.
Takahashi, Toshiaki; Murayama, Ryoko; Oe, Makoto; Nakagami, Gojiro; Tanabe, Hidenori; Yabunaka, Koichi; Arai, Rika; Komiyama, Chieko; Uchida, Miho; Sanada, Hiromi
Short peripheral catheter (SPC) failure is an important clinical problem. The purpose of this study was to clarify the relationship between SPC failure and etiologies such as thrombus, subcutaneous edema, and catheter dislodgment using ultrasonography and to explore the risk factors associated with the etiologies. Two hundred catheters that were in use for infusion, excluding chemotherapy, were observed. Risk factors were examined by logistic regression analysis. Sixty catheters were removed as the result of SPC failure. Frequency of thrombus with subcutaneous edema in SPC failure cases was significantly greater than in those cases where therapy was completed without complications (P < .01). Multivariate analysis demonstrated that 2 or more insertion attempts were significantly associated with thrombus with subcutaneous edema. Results suggest that subsurface skin assessment for catheterization could prevent SPC failure.
Thayikkannu, Ambujavalli Balakrishnan; Kindo, Anupma Jyoti; Veeraraghavan, Mahalakshmi
2015-01-01
Genus Malassezia comprises of 14 species of “yeast like fungi,” 13 of which are lipophilic and 1 is nonlipophilic. They are known commensals and in predisposed individuals they commonly cause a spectrum of chronic recurrent infections. They rarely also cause serious illnesses like catheter-related blood stream infections, CAPD associated peritonitis etc., Though these fungi have been known to man for over 150 years, their fastidious nature and cumbersome culture and speciation techniques have restricted research. Since the last taxonomic revision, seven new species have been added to this genus. Their ability to evade the host immune system and virulence has increased the spectrum of the diseases caused by them. These agents have been implicated as causal agents in common diseases like atopic dermatitis recently. Though culture-based research is difficult, the new molecular analysis techniques and facilities have increased research in this field such that we can devote more attention to this genus to study in detail, their characteristics and their growing implications implications in the clinical scenario. PMID:26288399
Abdominal paracentesis and thoracocentesis.
Lee, Ser Yee; Pormento, James G; Koong, Heng Nung
2009-04-01
Abdominal paracentesis and thoracocentesis are common bedside procedures with diagnostic, therapeutic and palliative roles. We describe a useful and familiar a useful and familiar technique with the use of a multiple lumen catheter commonly used for central venous line insertion for drainage of ascites or moderate to large pleural effusions. The use of a multiple lumen catheter allows easier and more rapid aspiration of fluid with a smaller probability of the side holes being blocked as compared to the standard needle or single catheter methods. This is particularly useful in situations where the dedicated commercial kits for thoracocentesis and abdominal paracentesis are not readily available.
Augusto, Renan Maloni; Albuquerque, André Luis Pereira; Jaeger, Thomas; de Carvalho, Carlos Roberto Ribeiro; Caruso, Pedro
2017-02-01
The use of esophageal catheters with microtransducer promises advantages over traditional catheters with air-filled balloons. However, performance comparisons between these 2 types of catheters are scarce and incomplete. A catheter with a 9.5-cm air-filled balloon at the distal tip and a catheter with a microtransducer mounted within a flexible silicone rubber were tested in vitro and in vivo. In vitro, the response times of both catheters were compared, and the drift of the baseline pressure of the microtransducer catheter was evaluated over a 6-h period. In vivo, 11 healthy volunteers had both catheters inserted, and the drift of the baseline esophageal pressure was measured over a 3-h period. Also, the correlation and agreement of the baseline and changes in the esophageal pressure of both catheters were evaluated. In vitro, the microtransducer catheter had a response time significantly higher (262 × 114 Hz, P < .01) and a good pressure stability, with a mean baseline pressure drift of 1.4 cm H 2 O. In vivo, both catheters presented a small and similar baseline esophageal pressure drift (P = 0.08). For measurements of baseline and changes in esophageal pressure, the correlation and agreement between the catheters were poor, with a large bias between them. The catheter with the microtransducer had a small baseline pressure drift, similar to the air-filled balloon catheter. The low agreement between the catheters does not allow the microtransducer catheter to be used as a surrogate for the traditional air-filled balloon catheter. Copyright © 2017 by Daedalus Enterprises.
Bagi, Per; Hannibalsen, Jane; Permild, Rikke; Stilling, Sine; Looms, Dagnia K
2011-01-01
A new compact male intermittent catheter was compared with a regular intermittent male catheter in terms of safety and acceptability. In this randomized, single-blind, cross-over study, healthy male volunteers were catheterized twice with a compact catheter and twice with a regular catheter. 28 participants were enrolled. Mean ± SD discomfort (visual analogue scale; primary objective) was 2.25 ± 1.5 and 2.52 ± 1.8 for the compact and regular catheters, respectively (difference -0.27; 95% confidence interval -0.73 to 0.19); there was no significant difference in hematuria (p = 0.54) or discomfort/stinging/pain at first micturition (p = 0.56). During insertion, handling was easier (p = 0.0001) and touching the coating was necessary less often (2.2 vs. 81.3% of catheterizations; p < 0.0001) with the compact catheter; it was preferred by nurses for 20 of 23 participants. No adverse events were reported. Short-term safety of the new compact catheter was at least as good as that of the regular male intermittent catheter and handling was improved. Copyright © 2011 S. Karger AG, Basel.
Fecal containment in bedridden patients: economic impact of 2 commercial bowel catheter systems.
Kowal-Vem, Areta; Poulakidas, Stathis; Barnett, Barbara; Conway, Deborah; Culver, Daniel; Ferrari, Michelle; Potenza, Bruce; Koenig, Michael; Mah, John; Majewski, Mary; Morris, Linda; Powers, Jan; Stokes, Elizabeth; Tan, Michael; Salstrom, Sara-Jane; Zaletel, Cindy; Ambutas, Shirley; Casey, Kathleen; Stein, Jayne; DeSane, Mary; Berry, Kathy; Konz, Elizabeth C; Riemer, Michael R; Cullum, Malford E
2009-05-01
Fecal contamination is a major challenge in patients in acute/critical care settings that is associated with increased cost of care and supplies and with development of pressure ulcers, incontinence dermatitis, skin and soft tissue infections, and urinary tract infections. To assess the economic impact of fecal containment in bedridden patients using 2 different indwelling bowel catheters and to compare infection rates between groups. A multicenter, observational study was done at 12 US sites (7 that use catheter A, 5 that use catheter B). Patients were followed from insertion of an indwelling bowel catheter system until the patient left the acute/critical care unit or until 29 days after enrollment, whichever came first. Demographic data, frequency of bedding/dressing changes, incidence of infection, and Braden scores (risk of pressure ulcers) were recorded. The study included 146 bedridden patients (76 with catheter A, 70 with catheter B) who had similar Braden scores at enrollment. The rate of bedding/dressing changes per day differed significantly between groups (1.20 for catheter A vs 1.71 for catheter B; P = .004). According to a formula that accounted for personnel resources and laundry cycle costs, catheter A cost $13.94 less per patient per day to use than did catheter B. Catheter A was less likely than was catheter B to be removed during the observational period (P = .03). Observed infection rates were low. Catheter A may be more cost-effective than catheter B because it requires fewer unscheduled linen changes per patient day.
Lutjeboer, Jacob; van Erkel, Arian R; van der Hoeven, J J M Koos; van der Meer, Rutger W
2015-01-01
Ascites can lead to many symptoms, and often occurs in patients with an end-stage malignancy such as ovarian, pancreatic, colonic, or gastric cancer. Intermittent ascites drainage is applied in these patients as a palliative measure. As frequent drainage is necessary, a subcutaneously tunnelled permanent ascites catheter is a good alternative for intermittent drainage. The patient can open - and then re-close - the catheter when abdominal pressure increases. We inserted 35 subcutaneously permanent ascites catheters in the course of the past 3.5 years in the Leiden University Medical Centre. The success rate was 100% and the complication risk was 2.9%. A subcutaneously tunnelled ascites catheter is an effective and safe palliative treatment for patients with end-stage malignant disease and suffering from ascites.
Microwave Treatment of Prostate Cancer and Hyperplasia
NASA Technical Reports Server (NTRS)
Arndt, G. Dickey; Ngo, Phong; Carl, J. R.; Raffoul, George
2005-01-01
Microwave ablation in the form of microwave energy applied to a heart muscle by a coaxial catheter inserted in a vein in the groin area can be used to heat and kill diseased heart cells. A microwave catheter has been developed to provide deep myocardial ablation to treat ventricular tachycardia by restoring appropriate electrical activity within the heart and eliminating irregular heartbeats. The resulting microwave catheter design, which is now being developed for commercial use in treating ventricular tachycardia, can be modified to treat prostate cancer and benign prostatic hyperplasia (BPH). Inasmuch as the occurrence of BPH is increasing currently 350,000 operations per year are performed in the United States alone to treat this condition this microwave catheter has significant commercial potential.
Konstantinou, Evangelos A; Stafylarakis, Emmanuil; Kapritsou, Maria; Mitsos, Aristotelis P; Fotis, Theofanis G; Kiekkas, Panagiotis; Mariolis-Sapsakos, Theodoros; Argyras, Eriphyli; Nomikou, Irini Th; Dimitrakopoulos, Antonios
2012-09-01
Placement of peripherally inserted central catheters (PICCs), definitely offers a clear advantage over any other method regarding central venous catheterization. Its ultrasonographic orientation enhances significantly its accuracy, safety and efficacy, making this method extremely comfortable for the patient who can continue his or her therapy even in an outpatient basis. We present the first reported case of a PICCS insertion in Greece, which has been performed by a university-degree nurse. The aim of this review of literature was to present the evolution in nursing practice in Greece. A PICC was inserted in a 77-year-old male patient suffering from a recent chemical pneumonia with a history of Alzheimer's disease. A description of all the technical details of this insertion is reported, focusing on the pros and cons of the method and a thorough review of the history and advances in central venous catheterization throughout the years is also presented. PICCs provide long-term intravenous access and facilitate the delivery of extended antibiotic therapy, chemotherapy and total parenteral nutrition. We strongly believe that PICCs are the safest and most effective method of peripherally inserted central venous catheterization. Larger series are necessary to prove the above hypothesis, and they are under construction by our team. Copyright © 2012 Society for Vascular Nursing, Inc. Published by Mosby, Inc. All rights reserved.
Evaluation of an active magnetic resonance tracking system for interstitial brachytherapy
Wang, Wei; Viswanathan, Akila N.; Damato, Antonio L.; Chen, Yue; Tse, Zion; Pan, Li; Tokuda, Junichi; Seethamraju, Ravi T.; Dumoulin, Charles L.; Schmidt, Ehud J.; Cormack, Robert A.
2015-01-01
Purpose: In gynecologic cancers, magnetic resonance (MR) imaging is the modality of choice for visualizing tumors and their surroundings because of superior soft-tissue contrast. Real-time MR guidance of catheter placement in interstitial brachytherapy facilitates target coverage, and would be further improved by providing intraprocedural estimates of dosimetric coverage. A major obstacle to intraprocedural dosimetry is the time needed for catheter trajectory reconstruction. Herein the authors evaluate an active MR tracking (MRTR) system which provides rapid catheter tip localization and trajectory reconstruction. The authors assess the reliability and spatial accuracy of the MRTR system in comparison to standard catheter digitization using magnetic resonance imaging (MRI) and CT. Methods: The MRTR system includes a stylet with microcoils mounted on its shaft, which can be inserted into brachytherapy catheters and tracked by a dedicated MRTR sequence. Catheter tip localization errors of the MRTR system and their dependence on catheter locations and orientation inside the MR scanner were quantified with a water phantom. The distances between the tracked tip positions of the MRTR stylet and the predefined ground-truth tip positions were calculated for measurements performed at seven locations and with nine orientations. To evaluate catheter trajectory reconstruction, fifteen brachytherapy catheters were placed into a gel phantom with an embedded catheter fixation framework, with parallel or crossed paths. The MRTR stylet was then inserted sequentially into each catheter. During the removal of the MRTR stylet from within each catheter, a MRTR measurement was performed at 40 Hz to acquire the instantaneous stylet tip position, resulting in a series of three-dimensional (3D) positions along the catheter’s trajectory. A 3D polynomial curve was fit to the tracked positions for each catheter, and equally spaced dwell points were then generated along the curve. High-resolution 3D MRI of the phantom was performed followed by catheter digitization based on the catheter’s imaging artifacts. The catheter trajectory error was characterized in terms of the mean distance between corresponding dwell points in MRTR-generated catheter trajectory and MRI-based catheter digitization. The MRTR-based catheter trajectory reconstruction process was also performed on three gynecologic cancer patients, and then compared with catheter digitization based on MRI and CT. Results: The catheter tip localization error increased as the MRTR stylet moved further off-center and as the stylet’s orientation deviated from the main magnetic field direction. Fifteen catheters’ trajectories were reconstructed by MRTR. Compared with MRI-based digitization, the mean 3D error of MRTR-generated trajectories was 1.5 ± 0.5 mm with an in-plane error of 0.7 ± 0.2 mm and a tip error of 1.7 ± 0.5 mm. MRTR resolved ambiguity in catheter assignment due to crossed catheter paths, which is a common problem in image-based catheter digitization. In the patient studies, the MRTR-generated catheter trajectory was consistent with digitization based on both MRI and CT. Conclusions: The MRTR system provides accurate catheter tip localization and trajectory reconstruction in the MR environment. Relative to the image-based methods, it improves the speed, safety, and reliability of the catheter trajectory reconstruction in interstitial brachytherapy. MRTR may enable in-procedural dosimetric evaluation of implant target coverage. PMID:26632065
Evaluation of an active magnetic resonance tracking system for interstitial brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Wei, E-mail: wwang21@partners.org; Viswanathan, Akila N.; Damato, Antonio L.
2015-12-15
Purpose: In gynecologic cancers, magnetic resonance (MR) imaging is the modality of choice for visualizing tumors and their surroundings because of superior soft-tissue contrast. Real-time MR guidance of catheter placement in interstitial brachytherapy facilitates target coverage, and would be further improved by providing intraprocedural estimates of dosimetric coverage. A major obstacle to intraprocedural dosimetry is the time needed for catheter trajectory reconstruction. Herein the authors evaluate an active MR tracking (MRTR) system which provides rapid catheter tip localization and trajectory reconstruction. The authors assess the reliability and spatial accuracy of the MRTR system in comparison to standard catheter digitization usingmore » magnetic resonance imaging (MRI) and CT. Methods: The MRTR system includes a stylet with microcoils mounted on its shaft, which can be inserted into brachytherapy catheters and tracked by a dedicated MRTR sequence. Catheter tip localization errors of the MRTR system and their dependence on catheter locations and orientation inside the MR scanner were quantified with a water phantom. The distances between the tracked tip positions of the MRTR stylet and the predefined ground-truth tip positions were calculated for measurements performed at seven locations and with nine orientations. To evaluate catheter trajectory reconstruction, fifteen brachytherapy catheters were placed into a gel phantom with an embedded catheter fixation framework, with parallel or crossed paths. The MRTR stylet was then inserted sequentially into each catheter. During the removal of the MRTR stylet from within each catheter, a MRTR measurement was performed at 40 Hz to acquire the instantaneous stylet tip position, resulting in a series of three-dimensional (3D) positions along the catheter’s trajectory. A 3D polynomial curve was fit to the tracked positions for each catheter, and equally spaced dwell points were then generated along the curve. High-resolution 3D MRI of the phantom was performed followed by catheter digitization based on the catheter’s imaging artifacts. The catheter trajectory error was characterized in terms of the mean distance between corresponding dwell points in MRTR-generated catheter trajectory and MRI-based catheter digitization. The MRTR-based catheter trajectory reconstruction process was also performed on three gynecologic cancer patients, and then compared with catheter digitization based on MRI and CT. Results: The catheter tip localization error increased as the MRTR stylet moved further off-center and as the stylet’s orientation deviated from the main magnetic field direction. Fifteen catheters’ trajectories were reconstructed by MRTR. Compared with MRI-based digitization, the mean 3D error of MRTR-generated trajectories was 1.5 ± 0.5 mm with an in-plane error of 0.7 ± 0.2 mm and a tip error of 1.7 ± 0.5 mm. MRTR resolved ambiguity in catheter assignment due to crossed catheter paths, which is a common problem in image-based catheter digitization. In the patient studies, the MRTR-generated catheter trajectory was consistent with digitization based on both MRI and CT. Conclusions: The MRTR system provides accurate catheter tip localization and trajectory reconstruction in the MR environment. Relative to the image-based methods, it improves the speed, safety, and reliability of the catheter trajectory reconstruction in interstitial brachytherapy. MRTR may enable in-procedural dosimetric evaluation of implant target coverage.« less
Witkowski, Maria Carolina; de Moraes, Maria Antonieta P.; Firpo, Cora Maria F.
2013-01-01
OBJECTIVE: To compare two systems of arterial catheters maintenance in postoperative pediatric surgery using intermittent or continuous infusion of heparin solution and to analyze adverse events related to the site of catheter insertion and the volume of infused heparin solution. METHODS: Randomized control trial with 140 patients selected for continuous infusion group (CIG) and intermittent infusion group (IIG). The variables analyzed were: type of heart disease, permanence time and size of the catheter, insertion site, technique used, volume of heparin solution and adverse events. The descriptive variables were analyzed by Student's t-test and the categorical variables, by chi-square test, being significant p<0.05. RESULTS: The median age was 11 (0-22) months, and 77 (55%) were females. No significant differences between studied variables were found, except for the volume used in CIG (12.0±1.2mL/24 hours) when compared to IIG (5.3±3.5mL/24 hours) with p<0.0003. CONCLUSIONS: The continuous infusion system and the intermittent infusion of heparin solution can be used for intra-arterial catheters maintenance in postoperative pediatric surgery, regardless of patient's clinical and demographic characteristics. Adverse events up to the third postoperative day occurred similarly in both groups. However, the intermittent infusion system usage in underweight children should be considered, due to the lower volume of infused heparin solution [ClinicalTrials.gov Identifier: NCT01097031]. PMID:24473958
Photoacoustic imaging of prostate brachytherapy seeds with transurethral light delivery
NASA Astrophysics Data System (ADS)
Lediju Bell, Muyinatu A.; Guo, Xiaoyu; Song, Danny Y.; Boctor, Emad M.
2014-03-01
We present a novel approach to photoacoustic imaging of prostate brachytherapy seeds utilizing an existing urinary catheter for transurethral light delivery. Two canine prostates were surgically implanted with brachyther- apy seeds under transrectal ultrasound guidance. One prostate was excised shortly after euthanasia and fixed in gelatin. The second prostate was imaged in the native tissue environment shortly after euthanasia. A urinary catheter was inserted in the urethra of each prostate. A 1-mm core diameter optical fiber coupled to a 1064 nm Nd:YAG laser was inserted into the urinary catheter. Light from the fiber was either directed mostly parallel to the fiber axis (i.e. end-fire fire) or mostly 90° to the fiber axis (i.e. side-fire fiber). An Ultrasonix SonixTouch scanner, transrectal ultrasound probe with curvilinear (BPC8-4) and linear (BPL9-5) arrays, and DAQ unit were utilized for synchronized laser light emission and photoacoustic signal acquisition. The implanted brachytherapy seeds were visualized at radial distances of 6-16 mm from the catheter. Multiple brachytherapy seeds were si- multaneously visualized with each array of the transrectal probe using both delay-and-sum (DAS) and short-lag spatial coherence (SLSC) beamforming. This work is the first to demonstrate the feasibility of photoacoustic imaging of prostate brachytherapy seeds using a transurethral light delivery method.
Kim-Saechao, Sue J; Almario, Earl; Rubin, Zachary A
2016-11-01
Peripherally inserted central catheters (PICCs) removed prematurely for unconfirmed infection or thrombosis lead to subsequent reinsertions and associated complications. To improve clinical quality, a mandatory electronic communication tool (MECT) based on clinical practice guidelines was mandated for all inpatient adult PICCs in an academically affiliated tertiary medical center. This MECT facilitated early communication and specialized evaluation with the PICC team for any complications related to PICCs. A historical cohort study was conducted. Quality and cost measurements for 200 PICCs postinstitution of a MECT were compared with 200 PICCs 12 months prior. PICC removal and complication rates were compared for the 2 cohorts. Significant outcomes included a central-line associated blood stream infection rate that changed from 1.38/1,000 catheter days to 0/1,000 catheter days, 0 provider-led premature PICC removals, an overall 84% decrease in premature PICC removals (from 16%-2.5%; P < .0001), a decrease in the total complication rate from 45.5%-24% (P < .0001), and 25% reduction in radiology costs. A novel infection prevention approach leveraging a MECT resulted in 0 central line-associated bloodstream infections and provider-led premature PICC removals. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Code of Federal Regulations, 2012 CFR
2012-10-01
... professional and technical components of any diagnostic test or procedure using x-rays, ultrasound...-ray, fluoroscopy, or ultrasound procedures that require the insertion of a needle, catheter, tube, or...
Code of Federal Regulations, 2013 CFR
2013-10-01
... professional and technical components of any diagnostic test or procedure using x-rays, ultrasound...-ray, fluoroscopy, or ultrasound procedures that require the insertion of a needle, catheter, tube, or...
Code of Federal Regulations, 2014 CFR
2014-10-01
... professional and technical components of any diagnostic test or procedure using x-rays, ultrasound...-ray, fluoroscopy, or ultrasound procedures that require the insertion of a needle, catheter, tube, or...
Saber, W.; Moua, T.; Williams, E. C.; Verso, M.; Agnelli, G.; Couban, S.; Young, A.; De Cicco, M.; Biffi, R.; van Rooden, C. J.; Huisman, M. V.; Fagnani, D.; Cimminiello, C.; Moia, M.; Magagnoli, M.; Povoski, S. P.; Malak, S. F.; Lee, A. Y.
2010-01-01
Background Knowledge of independent, baseline risk factors of catheter-related thrombosis (CRT) may help select adult cancer patients at high risk to receive thromboprophylaxis. Objectives We conducted a meta-analysis of individual patient-level data to identify these baseline risk factors. Patients/Methods MEDLINE, EMBASE, CINAHL, CENTRAL, DARE, Grey literature databases were searched in all languages from 1995-2008. Prospective studies and randomized controlled trials (RCTs) were eligible. Studies were included if original patient-level data were provided by the investigators and if CRT was objectively confirmed with valid imaging. Multivariate logistic regression analysis of 17 prespecified baseline characteristics was conducted. Adjusted odds ratios (OR) and 95% confidence intervals (CI) were estimated. Results A total sample of 5636 subjects from 5 RCTs and 7 prospective studies was included in the analysis. Among these subjects, 425 CRT events were observed. In multivariate logistic regression, the use of implanted ports as compared with peripherally implanted central venous catheters (PICC), decreased CRT risk (OR = 0.43; 95% CI, 0.23-0.80), whereas past history of deep vein thrombosis (DVT) (OR = 2.03; 95% CI, 1.05-3.92), subclavian venipuncture insertion technique (OR = 2.16; 95% CI, 1.07-4.34), and improper catheter tip location (OR = 1.92; 95% CI, 1.22-3.02), increased CRT risk. Conclusions CRT risk is increased with using PICC catheters, previous history of DVT, subclavian venipuncture insertion technique and improper positioning of the catheter tip. These factors may be useful for risk stratifying patients to select those for thromboprophylaxis. Prospective studies are needed to validate these findings. PMID:21040443
Wu, Hsiang-Ling; Tai, Ying-Hsuan; Wei, Ling-Fang; Cheng, Hung-Wei; Ho, Chiu-Ming
2017-10-01
There is no current consensus on which lumen an airway exchange catheter (AEC) should be passed through in double-lumen endotracheal tube (DLT) to exchange for a single-lumen endotracheal tube (SLT) after thoracic surgery. We report an unusual case to provide possible solution on this issue. A 71-year-old man with lung adenocarcinoma had an event of a broken exchange catheter used during a DLT replacement with a SLT, after a video-assisted thoracic surgery. The exchange catheter was impinged at the distal tracheal lumen and snapped during manipulation. All three segments of the catheter were retrieved without further airway compromises. Placement of airway tube exchanger into the tracheal lumen of double-lumen tube is a potential contributing factor of the unusual complication. We suggest an exchange catheter be inserted into the bronchial lumen in optimal depth with the adjunct of video laryngoscope, as the safe method for double-lumen tube exchange.
A simple method for long-term biliary access in large animals.
Andrews, J C; Knutsen, C; Smith, P; Prieskorn, D; Crudip, J; Klevering, J; Ensminger, W D
1988-07-01
A simple method to obtain long-term access to the biliary tree in dogs and pigs is presented. In ten dogs and four pigs, a cholecystectomy was performed, the cystic duct isolated, and a catheter inserted into the cut end of the cystic duct. The catheter was connected to a subcutaneous infusion port, producing a closed, internal system to allow long-term access. The catheter placement was successful in three of the pigs and all of the dogs. Thirty-five cholangiograms were obtained in the 13 subjects by accessing the port with a 20 gauge Huber needle and injecting small amounts (4-10 mL) of contrast under fluoroscopic control. Cholangiograms were obtained up to four months after catheter placement without evidence for catheter failure or surgically induced changes in the biliary tree. This model provides a simple, reliable means to obtain serial cholangiograms in a research setting.
Infection Prophylaxis in Peritoneal Dialysis Patients: Results from an Australia/New Zealand Survey.
Campbell, Denise J; Mudge, David W; Gallagher, Martin P; Lim, Wai Hon; Ranganathan, Dwaraka; Saweirs, Walaa; Craig, Jonathan C
2017-01-01
♦ BACKGROUND: Clinical practice guidelines aim to reduce the rates of peritoneal dialysis (PD)-related infections, a common complication of PD in end-stage kidney disease patients. We describe the clinical practices used by Australian and New Zealand nephrologists to prevent PD-related infections in PD patients. ♦ METHODS: A survey of PD practices in relation to the use of antibiotic and antifungal prophylaxis in PD patients was conducted of practicing nephrologists identified via the Australia and New Zealand Society of Nephrology (ANZSN) membership in 2013. ♦ RESULTS: Of 333 nephrologists approached, 133 (39.9%) participated. Overall, 127 (95.5%) nephrologists prescribed antibiotics at the time of Tenckhoff catheter insertion, 85 (63.9%) routinely screened for nasal S. aureus carriage, with 76 (88.4%) reporting they treated S. aureus carriers with mupirocin ointment. Following Tenckhoff catheter insertion, 79 (59.4%) prescribed mupirocin ointment at the exit site or intranasally, and 93 (69.9%) nephrologists routinely prescribed a course of oral antifungal agent whenever their PD patients were given a course of antibiotics. ♦ CONCLUSIONS: Although the majority of nephrologists prescribe antibiotics at the time of Tenckhoff catheter insertion, less than 70% routinely prescribe mupirocin ointment and/or prophylactic antifungal therapy. This variation in practice in Australia and New Zealand may contribute to the disparity in PD-related infection rates that is seen between units. Copyright © 2017 International Society for Peritoneal Dialysis.
Chopra, Vineet; Kuhn, Latoya; Vaughn, Valerie; Ratz, David; Winter, Suzanne; Moureau, Nancy; Meyer, Britt; Krein, Sarah
2017-12-01
: Background: Although certification by an accredited agency is often a practice prerequisite in health care, it is not required of vascular access specialists who insert peripherally inserted central catheters (PICCs). Whether certification is associated with differences in practice among inserters is unknown. The purpose of this study was to gather information regarding whether certified and noncertified PICC inserters differ with respect to their practices and views about PICC use. We conducted a national survey of vascular access specialists, identifying certified PICC inserters as those who had received board certification from the Association for Vascular Access, the Infusion Nurses Society, or both. The 76-item survey asked about PICC policies and procedures at respondents' facilities, use of insertion technologies, device management, management of complications, perceptions about PICC use, and relationships with other health care providers. Additional data about respondents, including years in practice and primary practice settings, were also gathered. Bivariable comparisons were made using χ tests; two-sided α with P ≤ 0.05 was considered statistically significant. Of the 1,450 respondents in the final sample, 1,007 (69%) said they were certified inserters and 443 (31%) said they were not. Significantly higher percentages of certified than noncertified inserters reported having practiced for five or more years (78% versus 54%) and having placed 1,000 or more PICCs (58% versus 32%). Significantly more certified than noncertified inserters also reported being the vascular access lead for their facility (56% versus 44%). Reported practice patterns for insertion, care, and management of PICCs varied based on certification status. Some evidence-based practices (such as the use of ultrasound to measure catheter-to-vein ratios) were more often reported by certified inserters, while others (such as the use of maximal sterile barriers during PICC insertion) were not. Asked about their perceptions of PICC use at their institution, certified inserters reported higher percentages of inappropriate insertion and removal than noncertified inserters. Certified PICC inserters appear to be a distinct group of vascular access specialists. A better understanding of how and why practices differ between certified and noncertified inserters is necessary to ensuring safer, high-quality patient care.
Taslakian, Bedros; Sridhar, Divya
2017-09-01
Interventional radiology (IR) has evolved into a full-fledged clinical specialty with attendant comprehensive patient care responsibilities. Providing excellent and thorough clinical care is as essential to the practice of IR as achieving technical success in procedures. Basic clinical skills that every interventional radiologist should learn include routine management of percutaneously inserted drainage and vascular catheters and rapid effective management of common systemic post-procedural complications. A structured approach to post-procedural care, including routine follow-up and early identification and management of complications, facilitates efficient and thorough management with an emphasis on quality and patient safety. The aim of this second part, in conjunction with part 1, is to complete the comprehensive review of post-procedural care in patients undergoing interventional radiology procedures. We discuss common problems encountered after insertion of drainage and vascular catheters and describe effective methods of troubleshooting these problems. Commonly encountered systemic complications in IR are described, and ways for immediate identification and management of these complications are provided.
Effect of Increased Plasma Osmolality on Cold-Induced Thirst Attenuation
2008-08-01
Xuid intake. Oropharyngeal and gastric stim- uli, as well as blood volume and plasma osmolality (Posm) are important factors modifying thirst (Greenleaf...reported to result in an increase in the osmotic thresh- old for the stimulation of thirst due to an increase in central blood volume (Sobocinska and...model 5877, Abbott Hospital, Inc., Chicago, IL, USA) was inserted into the catheter port for acquisition of subsequent blood samples. The catheter
2013-01-01
inferior venae cavae , pumped through a respiratory mem- brane, and returned into the right atrium . The insertion of these cathe- ters is...sheath and advanced through the superior vena cava and the right atrium into the inferior vena cava . Correct position was confirmed via fluoroscopy...these catheters, blood is drained from the superior and inferior venae cavae through two dedicated ports and is pumped through a respiratory
NASA Astrophysics Data System (ADS)
Diederich, Chris J.; Wootton, Jeff; Prakash, Punit; Salgaonkar, Vasant; Juang, Titania; Scott, Serena; Chen, Xin; Cunha, Adam; Pouliot, Jean; Hsu, I. C.
2011-09-01
Interstitial and endocavity ultrasound devices have been developed specifically for applying hyperthermia within temporary HDR brachytherapy implants during radiation therapy. Catheter-based ultrasound applicators are capable of 3D spatial control of heating in both angle and length of the devices, with enhanced radial penetration of heating compared to other hyperthermia technologies. A pilot study of the combination of catheter based ultrasound with HDR brachytherapy for locally advanced prostate and cervical cancer has been initiated, and preliminary results of the performance and heating distributions are reported herein. The treatment delivery platform consists of a 32 channel RF amplifier and a 48 channel thermocouple monitoring system. Controlling software can monitor and regulate frequency and power to each transducer section as required during the procedure. Interstitial applicators consist of multiple transducer sections of 2-4 cm length×180 deg and 3-4 cm×360 deg. heating patterns to be inserted in specific placed 13g implant catheters. The endocavity device, designed to be inserted within a 6 mm OD plastic tandem catheter within the cervix, consists of 2-3 transducers x dual 180 or 360 deg sectors. 3D temperature based treatment planning and optimization is dovetailed to the HDR optimization based planning to best configure and position the applicators within the catheters, and to determine optimal base power levels to each transducer section. To date we have treated eight cervix implants and four prostate implants. 100% of treatments achieved a goal of >60 min duration, with therapeutic temperatures achieved in all cases. Thermal dosimetry within the hyperthermia target volume (HTV) and clinical target volume (CTV) are reported. Catheter-based ultrasound hyperthermia with HDR appears feasible with therapeutic temperature coverage of the target volume within the prostate or cervix while sparing surrounding more sensitive regions.
In vivo dose verification method in catheter based high dose rate brachytherapy.
Jaselskė, Evelina; Adlienė, Diana; Rudžianskas, Viktoras; Urbonavičius, Benas Gabrielis; Inčiūra, Arturas
2017-12-01
In vivo dosimetry is a powerful tool for dose verification in radiotherapy. Its application in high dose rate (HDR) brachytherapy is usually limited to the estimation of gross errors, due to inability of the dosimetry system/ method to record non-uniform dose distribution in steep dose gradient fields close to the radioactive source. In vivo dose verification in interstitial catheter based HDR brachytherapy is crucial since the treatment is performed inserting radioactive source at the certain positions within the catheters that are pre-implanted into the tumour. We propose in vivo dose verification method for this type of brachytherapy treatment which is based on the comparison between experimentally measured and theoretical dose values calculated at well-defined locations corresponding dosemeter positions in the catheter. Dose measurements were performed using TLD 100-H rods (6 mm long, 1 mm diameter) inserted in a certain sequences into additionally pre-implanted dosimetry catheter. The adjustment of dosemeter positioning in the catheter was performed using reconstructed CT scans of patient with pre-implanted catheters. Doses to three Head&Neck and one Breast cancer patient have been measured during several randomly selected treatment fractions. It was found that the average experimental dose error varied from 4.02% to 12.93% during independent in vivo dosimetry control measurements for selected Head&Neck cancer patients and from 7.17% to 8.63% - for Breast cancer patient. Average experimental dose error was below the AAPM recommended margin of 20% and did not exceed the measurement uncertainty of 17.87% estimated for this type of dosemeters. Tendency of slightly increasing average dose error was observed in every following treatment fraction of the same patient. It was linked to the changes of theoretically estimated dosemeter positions due to the possible patient's organ movement between different treatment fractions, since catheter reconstruction was performed for the first treatment fraction only. These findings indicate potential for further average dose error reduction in catheter based brachytherapy by at least 2-3% in the case that catheter locations will be adjusted before each following treatment fraction, however it requires more detailed investigation. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Technical aids for the flexible use of the Leksell stereotactic system.
Salcman, M; Bellis, E H; Sewchand, W; Amin, P
1989-06-01
As part of a multimodality therapy program for intracranial tumours, 105 stereotactic and implant procedures have been carried out utilizing the CT-compatible Leksell stereotactic system. In the iridium implant series, 86 catheters have been implanted for an average of 3.6 targets per patient. There have been no deaths or missed targets and only two incidential haemorrhages detected. In order to facilitate the reliability, safety and speed of multiple catheter insertion, several techniques have been developed including: (a) a standardized single-length catheter and flange system; (b) a ceramic catheter for microwave hyperthermia; (c) a mnemonic card for ease of calculation; (d) a radiation shield for nursing; (e) a stereotactic drill and surgical approaches to far lateral and posterior fossa targets. Principles for the use of these technical aids are discussed.
Aufdenblatten, Christoph Alexander; Altermatt, Stefan
2008-09-01
In the management of severe head injuries, the use of intraventricular catheters for intracranial pressure (ICP) monitoring and the option of cerebrospinal fluid drainage is gold standard. In children and adolescents, the insertion of a cannula in a compressed ventricle in case of elevated intracranial pressure is difficult; therefore, a pressure sensor is placed more often intraparenchymal as an alternative option. In cases of persistent elevated ICP despite maximal brain pressure management, the use of an intraventricular monitoring device with the possibility of cerebrospinal fluid drainage is favourable. We present the method of intracranial catheter placement by means of an electromagnetic navigation technique.
Rare malposition following left jugular vein catheterization: Case reports and a literature review.
Wang, Lin; Liu, Zhangsuo; Wang, Changan; Liu, Dongwei; Yuan, Yiqiang
2015-01-01
The number of patients requiring chronic hemodialysis via a tunneled cuffed catheter is increasing. The right internal jugular vein (IJV) is generally the preferred site of percutaneous insertion. In certain situations, for example, in patients with a history of multiple access failures, catheterization of the left IJV is an important option. In this report, we present two rare cases of catheter malposition after left IJV catheterization; catheter adjustments, with the help of chest radiographs, resulted in a positive outcome in both cases. These cases exemplify the difficulties associated with left IJV catheterization, of which there are few reports in the published literature.
Rectus sheath catheter infusions for post-operative pain management.
Layzell, Mandy
2014-06-24
Managing pain following major abdominal surgery remains a challenge. Traditionally, patient-controlled analgesia (PCA) or epidural analgesia have been used, which have improved post-operative pain and the patient experience, but have presented some problems in recovery. PCA can cause adverse effects, including sedation, nausea, vomiting, and prolonged gastric ileus. While epidurals do have some advantages over PCA, there are risks involved related to catheter insertion and adverse effects, such as hypotension and motor blocks which limit mobility. This article examines rectus sheath catheter infusions, a relatively new and alternative technique to epidural analgesia, and presents some early audit data related to pain scores, analgesic use and mobility.
Chebroux, A; Leece, E A; Brearley, J C
2015-04-01
To evaluate animal comfort and ease of placement of a veterinary-specific intravenous catheter compared with a catheter manufactured for human use. Fifty-nine veterinary undergraduates were recruited to perform intravenous catheterisations with two brands of over-the-needle catheter [Smiths Medical Jelco® (human use) and Abbott Animal Health catheter® (veterinary use)] in 69 healthy cats (n = 28) and dogs (n = 41) requiring general anaesthesia. After a standardised pre-anaesthetic medication, each animal was randomly allocated to have one of the two brands of catheter placed. Each student was allowed a maximum of three attempts to achieve cephalic vein catheterisation. The student and a single experienced observer evaluated each attempt. Observations related to ease of placement and to the animal's reaction were recorded. Human use catheters were placed in 34 and veterinary use in 35 animals. There was no difference in weight, sex or sedation score between the two groups. The number of failed attempts was similar between the two groups. There was no difference between groups for the number of animals reacting to catheter insertion. The two types of catheters evaluated are equally suitable for intravenous catheterisation of sedated animals by veterinary undergraduate students. © 2015 British Small Animal Veterinary Association.
Hoss, Daniel R; Bedros, Antranik A; Mesipam, Avinash; Criddle, Jared; Smith, Jason C
2017-03-01
To determine if severe neutropenia at the time of chest port insertion is a risk factor for port removal and central catheter-associated bloodstream infection (CCABSI) in pediatric patients. From May 2007 to June 2015, 183 consecutive patients (mean age, 9.9 y; range, 0.75-21 y) had a port inserted at a single tertiary pediatric center. Seventy-two had severe neutropenia at the time of port insertion (absolute neutrophil count [ANC] range, 0-500/mm 3 ; mean, 185/mm 3 ). Follow-up until port removal or death and CCABSI events were recorded. Within the first 30 days, similar incidences of CCABSI (12.5% of patients with severe neutropenia [n = 9] vs 4.5% of patients without [n = 5]), port removal for infection (2.8% [n = 2] vs 2.7% [n = 3]), and local port infection (2.8% [n = 2] vs 0.9% [n = 1]) were observed in both groups (P > .05), but the rate of CCABSI per 1,000 catheter-days was higher for patients with severe neutropenia (P = .045). Overall, similar incidences of CCABSI (18.1% [n = 13] vs 16.2% [n = 18]), port removal for infection (2.8% [n = 2] vs 7.2% [n = 8]), local port infection (2.8% [n = 2] vs 2.7% [n = 3]), and CCABSIs per 1,000 catheter-days (0.332 vs 0.400) were observed in both groups (P > .05). Port placement in patients with severe neutropenia can be performed without an increased incidence of port removal for infection. The majority of CCABSIs were successfully treated without port removal. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.
Chen, Shih-Hsiang; Yang, Chao-Ping; Jaing, Tang-Her; Lai, Jin-Yao; Hung, Iou-Jih
2012-04-01
Long-term central venous catheter (CVC) implantation has become more affordable in Taiwan since 1995. Surgical removal of the catheter may be the essential treatment for catheter-related bloodstream infections (CRBSI). The aim of this study was to evaluate the clinical features and microbial isolates in pediatric cancer patients with removal of CVC for CRBSI. The records of positive blood culture from hospitalized pediatric oncology patients between 1995 and 2004 were reviewed. One hundred and forty-three patients implanted with a long-term CVC were further identified. Seventeen catheters in 16 patients developed catheter-related bacteremia that needed catheter removal. The rate of catheter removal was 11.9%. The median device life was 7.7 months. Six catheters were removed within 3 months of insertion. Nine of the 17 catheters were removed from patient younger than 2 years. Eight infections occurred during severe neutropenia, and 6 patients had refractory or relapsed underlying disease. The cultural isolates were Gram-negative bacilli in 7, Gram-positive in 5, fungi in 5, and atypical mycobacterium in 1. The frequency of catheter removal for infection control was significantly higher in the first 5 years (1994-1999) compared to the last 5 years (2000-2004) (30.9 vs. 4.0%, p = 2.3 × 10(-4)). Factors such as microbiological isolates, age of infection, the status of malignancy, and neutropenia are related to catheter outcome. The reduction in patients with positive cultures needing removal of the catheters can be related to improved nursing care and more aggressive antibiotic therapy.
Rodrigues, A F; van Mourik, I D M; Sharif, K; Barron, D J; de Giovanni, J V; Bennett, J; Bromley, P; Protheroe, S; John, P; de Ville de Goyet, J; Beath, S V
2006-04-01
The 3-year survival after small bowel transplantation (SBTx) has improved to between 73% and 88%. Impaired venous access for parenteral nutrition can be an indication for SBTx in children with chronic intestinal failure. To report our experience in management of children with extreme end-stage venous access. The study consisted of 6 children (all boys), median age of assessment 27 months (range, 13-52 months), diagnosed with total intestinal aganglionosis (1), protracted diarrhea (1), and short bowel syndrome (4), of which gastroschisis (2) and malrotation with midgut volvulus (2) were the causes. All had a documented history of more than 10 central venous catheter insertions previously. All had venograms, and 1 child additionally had a magnetic resonance angiogram to evaluate venous access. Five of 6 presented with thrombosis of the superior vena cava (SVC) and/or inferior vena cava. Venous access was reestablished as follows: transhepatic venous catheters (5), direct intra-atrial catheter via midline sternotomy (4), azygous venous catheters (2), dilatation of left subclavian vein after passage of a guide wire and then placing a catheter to reach the right atrium (1), radiological recanalization of the SVC and placement of a central venous catheter in situ (1), and direct puncture of SVC stump(1). Complications included serous pleural effusion after direct intra-atrial line insertion, which resolved after chest drain insertion (1), displacement of transhepatic catheter needing repositioning (2), and SVC stent narrowing requiring repeated balloon dilatation. Four children with permanent intestinal failure on assessment were offered SBTx, 3 of which were transplanted and were established on full enteral nutrition; the family of 1 child declined the procedure. In the remaining 2 children in whom bowel adaptation was still a possibility, attempts were made to provide adequate central venous access as feeds and drug manipulations were undertaken. One of them received liver and SBTx nearly 3 years after presenting with end-stage central venous access, because attempts to achieve independence from parenteral nutrition had failed. The other child died immediately after a transhepatic venous catheter placement, possibly from a nutritional depletion syndrome as no physical cause of death was found. Direct intra-atrial catheters in transplanted children proved to be adequate for the management of uncomplicated transplantation, although the usual infusion protocol had to be modified considerably, and the lack of access would have been critical if massive blood transfusion had been required during the transplant procedure. It was possible to reestablish central venous access in all cases. However, this was time consuming and difficult to assemble a skilled team consisting of one of more: surgeon, cardiologist, interventional radiologist, and transplant anesthetist. Small bowel transplantation is easier and safer with adequate central venous access, and we advocate liaison with an SBTx center at an early stage.
NASA Astrophysics Data System (ADS)
Beigi, Parmida; Rohling, Robert
2014-03-01
Despite the wide range and long history of ultrasound guided needle insertions, an unresolved issue in many cases is clear needle visibility. A well-known ad hoc technique to detect the needle is to move the stylet and look for changes in the needle appearance. We present a new method to automatically locate a moving stylet/catheter within a stationary cannula using motion detection. We then use this information to detect the needle trajectory and the tip. The differences between the current frame and the previous frame are detected and localized, to minimize the influence of tissue global motions. A polynomial fit based on the detected needle axis determines the estimated stylet shaft trajectory, and the extent of the differences along the needle axis represents the tip. Over a few periodic movements of the stylet including its full insertion into the cannula to the tip, a combination of polynomial fits determines the needle trajectory and the last detected point represents the needle tip. Experiments are conducted in water bath and bovine muscle tissue for several stylet/catheter materials. Results show that a plastic stylet has the best needle shaft and tip localization accuracy in the water bath with RMSE = 0:16 mm and RMSE = 0:51 mm, respectively. In the bovine tissue, the needle tip was best localized with the plastic catheter with RMSE = 0:33 mm. The stylet tip localization was most accurate with the steel stylet, with RMSE = 2:81 mm and the shaft was best localized with the plastic catheter, with RMSE = 0:32 mm.
Number and location of drainage catheter side holes: in vitro evaluation.
Ballard, D H; Alexander, J S; Weisman, J A; Orchard, M A; Williams, J T; D'Agostino, H B
2015-09-01
To evaluate the influence of number and location of catheter shaft side holes regarding drainage efficiency in an in vitro model. Three different drainage catheter models were constructed: open-ended model with no side holes (one catheter), unilateral side hole model (six catheters with one to six unilateral side holes), and bilateral side hole model (six catheters with one to six bilateral side holes). Catheters were inserted into a drainage output-measuring device with a constant-pressure reservoir of water. The volume of water evacuated by each of the catheters at 10-second intervals was measured. A total of five trials were performed for each catheter. Data were analysed using one-way analysis of variance. The open-ended catheter had a mean drainage volume comparable to the unilateral model catheters with three, four, and five side holes. Unilateral model catheters had significant drainage volume increases up to three side holes; unilateral model catheters with more than three side holes had no significant improvement in drainage volume. All bilateral model catheters had significantly higher mean drainage volumes than their unilateral counterparts. There was no significant difference between the mean drainage volume with one, two, or three pairs of bilateral side holes. Further, there was no drainage improvement by adding additional bilateral side holes. The present in vitro study suggests that beyond a critical side hole number threshold, adding more distal side holes does not improve catheter drainage efficiency. These results may be used to enhance catheter design towards improving their drainage efficiency. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Diederich, Chris J.; Wootton, Jeff; Prakash, Punit; Salgaonkar, Vasant; Juang, Titania; Scott, Serena; Chen, Xin; Cunha, Adam; Pouliot, Jean; Hsu, I. C.
2011-03-01
A clinical treatment delivery platform has been developed and is being evaluated in a clinical pilot study for providing 3D controlled hyperthermia with catheter-based ultrasound applicators in conjunction with high dose rate (HDR) brachytherapy. Catheter-based ultrasound applicators are capable of 3D spatial control of heating in both angle and length of the devices, with enhanced radial penetration of heating compared to other hyperthermia technologies. Interstitial and endocavity ultrasound devices have been developed specifically for applying hyperthermia within HDR brachytherapy implants during radiation therapy in the treatment of cervix and prostate. A pilot study of the combination of catheter based ultrasound with HDR brachytherapy for locally advanced prostate and cervical cancer has been initiated, and preliminary results of the performance and heating distributions are reported herein. The treatment delivery platform consists of a 32 channel RF amplifier and a 48 channel thermocouple monitoring system. Controlling software can monitor and regulate frequency and power to each transducer section as required during the procedure. Interstitial applicators consist of multiple transducer sections of 2-4 cm length × 180 deg and 3-4 cm × 360 deg. heating patterns to be inserted in specific placed 13g implant catheters. The endocavity device, designed to be inserted within a 6 mm OD plastic tandem catheter within the cervix, consists of 2-3 transducers × dual 180 or 360 deg sectors. 3D temperature based treatment planning and optimization is dovetailed to the HDR optimization based planning to best configure and position the applicators within the catheters, and to determine optimal base power levels to each transducer section. To date we have treated eight cervix implants and six prostate implants. 100 % of treatments achieved a goal of >60 min duration, with therapeutic temperatures achieved in all cases. Thermal dosimetry within the hyperthermia target volume (HTV) and clinical target volume (CTV) are reported. Catheter-based ultrasound hyperthermia with HDR appears feasible with therapeutic temperature coverage of the target volume within the prostate or cervix while sparing surrounding more sensitive regions.
Incidence of Central Vein Stenosis and Occlusion Following Upper Extremity PICC and Port Placement
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gonsalves, Carin F., E-mail: Carin.Gonsalves@mail.tju.edu; Eschelman, David J.; Sullivan, Kevin L.
2003-04-15
The purpose of this study was to determine the incidence of central vein stenosis and occlusion following upper extremity placement of peripherally inserted central venous catheters(PICCs) and venous ports. One hundred fifty-four patients who underwent venography of the ipsilateral central veins prior to initial and subsequent venous access device insertion were retrospectively identified. All follow-up venograms were interpreted at the time of catheter placement by one interventional radiologist over a 5-year period and compared to the findings on initial venography. For patients with central vein abnormalities, hospital and home infusion service records and radiology reports were reviewed to determine cathetermore » dwelltime and potential alternative etiologies of central vein stenosis or occlusion. The effect of catheter caliber and dwell time on development of central vein abnormalities was evaluated. Venography performed prior to initial catheter placement showed that 150 patients had normal central veins. Three patients had central vein stenosis, and one had central vein occlusion. Subsequent venograms (n = 154)at the time of additional venous access device placement demonstrated 8 patients with occlusions and 10 with stenoses. Three of the 18 patients with abnormal follow-up venograms were found to have potential alternative causes of central vein abnormalities. Excluding these 3 patients and the 4 patients with abnormal initial venograms, a 7% incidence of central vein stenosis or occlusion was found in patients with prior indwelling catheters and normal initial venograms. Catheter caliber showed no effect on the subsequent development of central vein abnormalities. Patients who developed new or worsened central vein stenosis or occlusion had significantly (p =0.03) longer catheter dwell times than patients without central vein abnormalities. New central vein stenosis or occlusion occurred in 7% of patients following upper arm placement of venous access devices.Patients with longer catheter dwell time were more likely to develop central vein abnormalities. In order to preserve vascular access for dialysis fistulae and grafts and adhere to Dialysis Outcomes Quality Initiative guidelines, alternative venous access sites should be considered for patients with chronic renal insufficiency and end-stage renal disease.« less
EXPANDING CAPD IN LOW-RESOURCE SETTINGS: A DISTANCE LEARNING APPROACH.
Rope, Robert; Nanayakkara, Nishantha; Wazil, Abdul; Dickowita, Sewmini; Abeyeskera, Rajitha; Gunerathne, Lishanthe; Adoosoriya, Dinuka; Karunasena, Nishamani; Ratnayake, Charaka; Anand, Shuchi; Saxena, Anjali
2018-05-23
Despite growing need, treatment for end-stage renal disease is limited in low- and middle-income countries due to resource restraints. We describe the development of an educational curriculum and quality improvement program to support continuous ambulatory peritoneal dialysis (CAPD) performed primarily by non-nephrology providers in Sri Lanka. We developed a program of education, outcome tracking, and expert consultation to support providers in Kandy, Sri Lanka. Education included videos and in-person didactics covering core topics in CAPD. Event-tracking sheets recorded root causes and management of infections and hospitalizations. Conferences reviewed clinical cases and overall clinic management. We evaluated the patient census, peritonitis rates, and root causes and management of infections over 1 year. The curriculum was published through the International Society of Nephrology online academy. High provider turnover limited curriculum assessments. The CAPD patient census rose from 63 to 116 during the year. The peritonitis rate declined significantly, from 0.8 episodes per patient-year in the first 6 months to 0.4 in the latter 6 months, though the most common root causes of peritonitis, related to contamination events and hygiene, persisted. The appropriate ascertainment of culture data and prescription of antibiotics also increased. Our project supported the expansion of a CAPD program in a resource-limited setting, while also improving peritonitis outcomes. Ongoing challenges include ensuring a durable educational system for rotating providers, tracking outcomes beyond peritonitis, and formalizing management protocols. Our program can serve as an example of how established dialysis programs can support the burgeoning work of providers in resource-limited setting.
Seiberlich, Laura E; Keay, Vanessa; Kallos, Stephane; Junghans, Tiffany; Lang, Eddy; McRae, Andrew D
2016-03-01
The performance of a new safety peripheral intravenous catheter (PIVC) that contains a blood control feature in the hub (blood control) was compared against the current hospital standard without blood control (standard). In this prospective, non-blinded trial, patients were randomized 1:1 to receive either device. Insertions were performed and rated by emergency room nurses. Primary endpoints included clinical acceptability, incidence of blood leakage, and risk of blood exposure. Secondary endpoints were digital compression, insertion success, and usability. 15 clinicians performed 152 PIVC insertions (73 blood control, 79 standard). Clinical acceptability of the blood control device (100%) was non-inferior to the standard (98.7%) (p < 0.0001). The blood control device had a lower incidence of blood leakage (14.1% vs 68.4%), was superior in eliminating the risk of blood exposure (93.9% vs 19.1%) and the need for digital compression (95.3% vs 19.1%), while maintaining non-inferior insertion success rates (95.9% vs 93.7%) and usability ratings (p < 0.0001). In comparison with the hospital-standard, the new safety PIVC with integrated blood control valve had similar clinical acceptability ratings yet demonstrated superior advantages to both clinicians and patients to decrease blood leakage and the clinician's risk of blood exposure, during the insertion process. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Moist heat intraluminal disinfection of CAPD connectors.
Fessia, S L; Grabowy, R S; Bousquet, G G
1990-01-01
A moist heat technique for disinfecting the inner lumen of commercially available connectology used in the exchange process for Continuous Ambulatory Peritoneal Dialysis (CAPD) was evaluated. Moist heat was generated by a device (PDM-1) that directed microwave energy to heat a sample solution containing a concentration of 10(6) microorganisms inside a pair of mated plastic CAPD connectors. Microorganisms tested included those most prevalent and most problematic in causing peritonitis. Testing, performed according to F.D.A. approved standards, involved heating a sample solution and then placing the sample solution into vials which were then sealed and incubated. Absolute determination of growth versus no growth was measured by macroscopic observation. Positive control samples were performed in the same manner but were not exposed to heat. Negative controls were performed in the same manner in the absence of test organisms. At temperatures of approximately 100 degrees C a D-value of 6.6 seconds was determined using the organism found the most thermoresistant. A cycle time of 54 seconds appeared sufficient to achieve a 10(6) population reduction of all microorganisms tested. The moist heat technique offers a safe, effective method for disinfection of the inner lumen of CAPD connectors.
Sayarlioglu, Hayriye; Topal, Cevat; Sayarlioglu, Mehmet; Dulger, Haluk; Dogan, Ekrem; Erkoc, Reha
2004-01-01
OBJECTIVE: It is known that glucose concentrations of peritoneal dialysis solutions are detrimental to the peritoneal membrane. In order to determine the effect of glucose concentration on cytokine levels of peritoneal fluid of continuous ambulatory peritoneal dialysis (CAPD) patients, a cross-sectional study was performed. METHODS: Nine non-diabetic CAPD patients participated in two 8-h dwell sessions of overnight exchanges in consecutive days, with 1.36% and 3.86% glucose containing peritoneal dialysis solutions (Baxter-Eczacibas). Peritoneal dialysis fluid tumor necrosis factor (TNF)-alpha and interleukin (IL)-6 levels were measured. RESULTS: TNF-alpha levels after 1.36% and 3.86% glucose used dwells were 23+/-14 pg/ml and 28+/-4 pg/ml, respectively (p=0.78). The IL-6 levels were 106+/-57 pg/ml and 115+/-63 pg/ml (p=0.81), respectively. CONCLUSION: In our in vivo study we found that the glucose concentration of the conventional lactate-based CAPD solution has no effect on basal IL-6 and TNF-alpha levels of peritoneal fluid. Further in vivo studies with non-lactate-based CAPD solutions are needed in order to determine the effect of glucose concentration per se on cytokine release. PMID:15203553
Laan, Bart J; Spijkerman, Ingrid J B; Godfried, Mieke H; Pasmooij, Berend C; Maaskant, Jolanda M; Borgert, Marjon J; Opmeer, Brent C; Vos, Margreet C; Geerlings, Suzanne E
2017-01-10
Urinary and (peripheral and central) intravenous catheters are widely used in hospitalized patients. However, up to 56% of the catheters do not have an appropriate indication and some serious complications with the use of these catheters can occur. The main objective of our quality improvement project is to reduce the use of catheters without an appropriate indication by 25-50%, and to evaluate the affecting factors of our de-implementation strategy. In a multicenter, prospective interrupted time series analysis, several interventions to avoid inappropriate use of catheters will be conducted in seven hospitals in the Netherlands. Firstly, we will define a list of appropriate indications for urinary and (peripheral and central) intravenous catheters, which will restrict the use of catheters and urge catheter removal when the indication is no longer appropriate. Secondly, after the baseline measurements, the intervention will take place, which consists of a kick-off meeting, including a competitive feedback report of the baseline measurements, and education of healthcare workers and patients. Additional strategies based on the baseline data and local conditions are optional. The primary endpoint is the percentage of catheters with an inappropriate indication on the day of data collection before and after the de-implementation strategy. Secondary endpoints are catheter-related infections or other complications, catheter re-insertion rate, length of hospital (and ICU) stay and mortality. In addition, the cost-effectiveness of the de-implementation strategy will be calculated. This study aims to reduce the use of urinary and intravenous catheters with an inappropriate indication, and as a result reduce the catheter-related complications. If (cost-) effective it provides a tool for a nationwide approach to reduce catheter-related infections and other complications. Dutch trial registry: NTR6015 . Registered 9 August 2016.
Fitch, Joseph P.; Hagans, Karla; Clough, Robert; Matthews, Dennis L.; Lee, Abraham P.; Krulevitch, Peter A.; Benett, William J.; Da Silva, Luiz; Celliers, Peter M.
1998-01-01
A micro-mechanical system for medical procedures is constructed in the basic form of a catheter having a distal end for insertion into and manipulation within a body and a near end providing for a user to control the manipulation of the distal end within the body. A fiberoptic cable is disposed within the catheter and having a distal end proximate to the distal end of the catheter and a near end for external coupling of laser light energy. A microgripper is attached to the distal end of the catheter and providing for the gripping or releasing of an object within the body. A laser-light-to-mechanical-power converter is connected to receive laser light from the distal end of the fiberoptic cable and connected to mechanically actuate the microgripper.
Fitch, J.P.; Hagans, K.; Clough, R.; Matthews, D.L.; Lee, A.P.; Krulevitch, P.A.; Benett, W.J.; Silva, L. Da; Celliers, P.M.
1998-03-03
A micro-mechanical system for medical procedures is constructed in the basic form of a catheter having a distal end for insertion into and manipulation within a body and a near end providing for a user to control the manipulation of the distal end within the body. A fiber-optic cable is disposed within the catheter and having a distal end proximate to the distal end of the catheter and a near end for external coupling of laser light energy. A microgripper is attached to the distal end of the catheter and providing for the gripping or releasing of an object within the body. A laser-light-to-mechanical-power converter is connected to receive laser light from the distal end of the fiber-optic cable and connected to mechanically actuate the microgripper. 22 figs.
Intracranial pressure monitoring (image)
Intracranial pressure monitoring is performed by inserting a catheter into the head with a sensing device to monitor the pressure around the brain. An increase in intracranial pressure can cause a decrease in blood flow to ...
Peripherally inserted central catheter - dressing change
... chlorhexidine) in a single-use small applicator Special sponges or wipes that contain a cleaning agent, such ... Clean your skin around the site with the sponge and cleaning solution for 30 seconds. Let the ...
Pacing threshold changes after transvenous catheter countershock.
Yee, R; Jones, D L; Klein, G J
1984-02-01
The serial changes in pacing threshold and R-wave amplitude were examined after insertion of a countershock catheter in 12 patients referred for management of recurrent ventricular tachyarrhythmias. In 6 patients, values before and immediately after catheter countershock were monitored. Pacing threshold increased (from 1.4 +/- 0.2 to 2.4 +/- 0.5 V, mean +/- standard error of the mean, p less than 0.05) while the R-wave amplitude decreased (bipolar R wave from 5.9 +/- 1.1 to 3.4 +/- 0.7 mV, p less than 0.01; unipolar R wave recorded from the distal ventricular electrode from 8.9 +/- 1.8 to 4.6 +/- 1.2 mV, p less than 0.01; and proximal ventricular electrode from 7.7 +/- 1.5 to 5.0 +/- 1.0 mV, p less than 0.01). A return to control values occurred within 10 minutes. In all patients, pacing threshold increased by 154 +/- 30% (p less than 0.001) during the first 7 days that the catheter was in place. It is concluded that catheter countershock causes an acute increase in pacing threshold and decrease in R-wave amplitude. A catheter used for countershock may not be acceptable as a backup pacing catheter.
Cohen, Elaine R; Feinglass, Joe; Barsuk, Jeffrey H; Barnard, Cynthia; O'Donnell, Anna; McGaghie, William C; Wayne, Diane B
2010-04-01
Interventions to reduce preventable complications such as catheter-related bloodstream infections (CRBSI) can also decrease hospital costs. However, little is known about the cost-effectiveness of simulation-based education. The aim of this study was to estimate hospital cost savings related to a reduction in CRBSI after simulation training for residents. This was an intervention evaluation study estimating cost savings related to a simulation-based intervention in central venous catheter (CVC) insertion in the Medical Intensive Care Unit (MICU) at an urban teaching hospital. After residents completed a simulation-based mastery learning program in CVC insertion, CRBSI rates declined sharply. Case-control and regression analysis methods were used to estimate savings by comparing CRBSI rates in the year before and after the intervention. Annual savings from reduced CRBSIs were compared with the annual cost of simulation training. Approximately 9.95 CRBSIs were prevented among MICU patients with CVCs in the year after the intervention. Incremental costs attributed to each CRBSI were approximately $82,000 in 2008 dollars and 14 additional hospital days (including 12 MICU days). The annual cost of the simulation-based education was approximately $112,000. Net annual savings were thus greater than $700,000, a 7 to 1 rate of return on the simulation training intervention. A simulation-based educational intervention in CVC insertion was highly cost-effective. These results suggest that investment in simulation training can produce significant medical care cost savings.
Compact Directional Microwave Antenna for Localized Heating
NASA Technical Reports Server (NTRS)
Fink, Patrick W.; Lin, Gregory Y.; Chu, Andrew W.; Dobbins, Justin A.; Arndt, G. Dickey; Ngo, Phong
2008-01-01
A directional, catheter-sized cylindrical antenna has been developed for localized delivery of microwave radiation for heating (and thus killing) diseased tissue without excessively heating nearby healthy tissue. By "localized" is meant that the antenna radiates much more in a selected azimuthal direction than in the opposite radial direction, so that it heats tissue much more on one side than it does on the opposite side. This antenna can be inserted using either a catheter or a syringe. A 2.4-mm prototype was tested, although smaller antennas are possible. Prior compact, cylindrical antennas designed for therapeutic localized hyperthermia do not exhibit such directionality; that is, they radiate in approximately axisymmetric patterns. Prior directional antennas designed for the same purpose have been, variously, (1) too large to fit within catheters or (2) too large, after deployment from catheters, to fit within the confines of most human organs. In contrast, the present antenna offers a high degree of directionality and is compact enough to be useable as a catheter in some applications.
Avelar, Ariane Ferreira Machado; Peterlini, Maria Angélica Sorgini; da Pedreira, Mavilde Luz Gonçalves
2013-06-01
Randomized controlled trial which aimed to verify whether the use of vascular ultrasound (VUS) increases assertiveness in the use of peripheral venous catheter in children, and the catheter dwell time, when compared to traditional puncture. Data were collected after approval of theethical merit. Children and adolescents undergoing VUS-guided peripheral intravenous (GVUS) or puncture guided by clinical assessment of the venous conditions(CG) were included in the study. Significance level was set at p< or =0.05. The sample was composed of 382 punctures, 188 (49.2%) in VUS Gand 194 (50.8%) in CG, performed in 335 children. Assertiveness was found in 73 (71.6%) GVUS catheters and in 84(71.8%) of the CG (p=0.970), and catheter dwell time presented a median of less than one day in both groups (p=0.121), showing nostatistically significant difference. VUS did not significantly influence the results of the dependent variables investigated. ClinicalTrials.govNCT00930254.
Temporary quadriplegia following continuous thoracic paravertebral block.
Calenda, Emile; Baste, Jean Marc; Danielou, Eric; Michelin, Paul
2012-05-01
A case of temporary quadriplegia following a continuous thoracic paravertebral block in an adult patient scheduled for video-assisted thoracoscopy is presented. An 18-gauge Tuohy needle was inserted under direct vision by the surgeon but the tip of the catheter was not localized. Postoperatively, the patient developed temporary quadriplegia 90 minutes after the start of a continuous infusion of ropivacaine 0.2%. Imaging studies showed that the catheter was localized in the intrathecal space. Copyright © 2012 Elsevier Inc. All rights reserved.
The Association between Peritoneal Dialysis Modality and Peritonitis
Johnson, David W.; McDonald, Stephen P.; Boudville, Neil; Borlace, Monique; Badve, Sunil V.; Sud, Kamal; Clayton, Philip A.
2014-01-01
Background and objectives There is conflicting evidence comparing peritonitis rates among patients treated with continuous ambulatory peritoneal dialysis (CAPD) or automated peritoneal dialysis (APD). This study aims to clarify the relationship between peritoneal dialysis (PD) modality (APD versus CAPD) and the risk of developing PD-associated peritonitis. Design, setting, participants, & measurements This study examined the association between PD modality (APD versus CAPD) and the risks, microbiology, and clinical outcomes of PD-associated peritonitis in 6959 incident Australian PD patients between October 1, 2003, and December 31, 2011, using data from the Australia and New Zealand Dialysis and Transplant Registry. Median follow-up time was 1.9 years. Results Patients receiving APD were younger (60 versus 64 years) and had fewer comorbidities. There was no association between PD modality and time to first peritonitis episode (adjusted hazard ratio [HR] for APD versus CAPD, 0.98; 95% confidence interval [95% CI], 0.91 to 1.07; P=0.71). However, there was a lower hazard of developing Gram-positive peritonitis with APD than CAPD, which reached borderline significance (HR, 0.90; 95% CI, 0.80 to 1.00; P=0.05). No statistically significant difference was found in the risk of hospitalizations (odds ratio, 1.12; 95% CI, 0.93 to 1.35; P=0.22), but there was a nonsignificant higher likelihood of 30-day mortality (odds ratio, 1.33; 95% CI, 0.93 to 1.88; P=0.11) at the time of the first episode of peritonitis for patients receiving APD. For all peritonitis episodes (including subsequent episodes of peritonitis), APD was associated with lower rates of culture-negative peritonitis (incidence rate ratio [IRR], 0.81; 95% CI, 0.69 to 0.94; P=0.002) and higher rates of gram-negative peritonitis (IRR, 1.28; 95% CI, 1.13 to 1.46; P=0.01). Conclusions PD modality was not associated with a higher likelihood of developing peritonitis. However, APD was associated with a borderline reduction in the likelihood of a first episode of Gram-positive peritonitis compared with CAPD, and with lower rates of culture-negative peritonitis and higher rates of Gram-negative peritonitis. Peritonitis outcomes were comparable between both modalities. PMID:24626434
Short-term infection in cuffed versus noncuffed small bore central catheters: a randomized trial.
Trerotola, Scott O; Patel, Aalpen A; Shlansky-Goldberg, Richard D; Solomon, Jeffrey A; Mondschein, Jeffrey I; Stavropoulos, S William; Soulen, Michael C; Itkin, Maxim; Chittams, Jesse
2010-02-01
To determine if a polyester cuff offered benefit in jugular small-bore central catheters (SBCCs). Eighty-four patients were randomly assigned to receive a 5-F single- or 6-F dual-lumen SBCC with (n = 42) or without (n = 42) a polyester cuff. Follow-up was performed at 2 weeks, 1 month, and 3 months or at catheter removal, whichever came first. At scheduled follow-up, catheter function, patient satisfaction, and infection were determined. At catheter removal, tip culture was performed to determine colonization and jugular vein patency was determined with ultrasonography (US). The overall infection rate was 0.4 per 1,000 catheter days. There was one clinical infection (noncuffed catheter). Colonization occurred in two noncuffed catheters and one cuffed catheter. There was one catheter dislodgment in the noncuffed group and none in the cuffed group. Cuffed catheters were no more difficult to insert but took slightly longer to remove (6 minutes +/- 4.7 vs 5 minutes +/- 3, P = .39) and often required local anesthesia for removal, whereas noncuffed catheters did not (41% vs 0%, P = .001). Partial (two cuffed, 0 noncuffed) or complete (two cuffed, one noncuffed) jugular thrombosis was seen on five of 58 completion US studies (8.6%). A polyester cuff on a SBCC confers no significant benefit in short-term colonization rates. Infection in SBCCs is uncommon. Despite their small diameters, SBCCs can result in jugular thrombosis, an important consideration in any patient requiring long-term venous access. Copyright (c) 2010 SIR. Published by Elsevier Inc. All rights reserved.
Performance evaluation of a robot-assisted catheter operating system with haptic feedback.
Song, Yu; Guo, Shuxiang; Yin, Xuanchun; Zhang, Linshuai; Hirata, Hideyuki; Ishihara, Hidenori; Tamiya, Takashi
2018-06-20
In this paper, a novel robot-assisted catheter operating system (RCOS) has been proposed as a method to reduce physical stress and X-ray exposure time to physicians during endovascular procedures. The unique design of this system allows the physician to apply conventional bedside catheterization skills (advance, retreat and rotate) to an input catheter, which is placed at the master side to control another patient catheter placed at the slave side. For this purpose, a magnetorheological (MR) fluids-based master haptic interface has been developed to measure the axial and radial motions of an input catheter, as well as to provide the haptic feedback to the physician during the operation. In order to achieve a quick response of the haptic force in the master haptic interface, a hall sensor-based closed-loop control strategy is employed. In slave side, a catheter manipulator is presented to deliver the patient catheter, according to position commands received from the master haptic interface. The contact forces between the patient catheter and blood vessel system can be measured by designed force sensor unit of catheter manipulator. Four levels of haptic force are provided to make the operator aware of the resistance encountered by the patient catheter during the insertion procedure. The catheter manipulator was evaluated for precision positioning. The time lag from the sensed motion to replicated motion is tested. To verify the efficacy of the proposed haptic feedback method, the evaluation experiments in vitro are carried out. The results demonstrate that the proposed system has the ability to enable decreasing the contact forces between the catheter and vasculature.
Bertani, Laura; Carone, Maria; Caricati, Luca; Demaria, Serena; Fantuzzi, Silvia; Guarasci, Alessandro; Pirazzoli, Luca
2016-11-22
The peripherally inserted central catheters (PICC) have become an alternative to the traditional CVC. PICCs are usually inserted by trained nurses who decided to attend and complete a special training on PICC insertion and management. The present work aimed to investigate the intention of using PICC in a sample of hospital-based nurses using the theory of planned behavior as theoretical framework. A cross-sectional design was used in which a questionnaire was delivered to 199 nurses. According to the theory of planned behavior, the attitude toward the use of PICC, subjective norms and perceived self-efficacy predicted the intention to use PICC. Contrary to the expectations, the effect of subjective norms on intention to use PICC was mediated by attitude and self-efficacy. Finally, age of participants was negatively related to the intention to use the PICC. The theory of planned behavior offers a useful framework to explain nurses' intention to use PICC. Shared norms favoring the use of PICC seem to increase both nurse's positive attitudes and self-efficacy whit respect to the use of these devices. Thus, it appears that to train professionals individually does not necessarily results in an increased use of PICC.
Bustos, Cesar; Aguinaga, Aitziber; Carmona-Torre, Francisco; Del Pozo, Jose Luis
2014-01-01
Since the first description in 1982, totally implanted venous access ports have progressively improved patients’ quality of life and medical assistance when a medical condition requires the use of long-term venous access. Currently, they are part of the standard medical care for oncohematologic patients. However, apart from mechanical and thrombotic complications, there are also complications associated with biofilm development inside the catheters. These biofilms increase the cost of medical assistance and extend hospitalization. The most frequently involved micro-organisms in these infections are gram-positive cocci. Many efforts have been made to understand biofilm formation within the lumen catheters, and to resolve catheter-related infection once it has been established. Apart from systemic antibiotic treatment, the use of local catheter treatment (ie, antibiotic lock technique) is widely employed. Many different antimicrobial options have been tested, with different outcomes, in clinical and in in vitro assays. The stability of antibiotic concentration in the lock solution once instilled inside the catheter lumen remains unresolved. To prevent infection, it is mandatory to perform hand hygiene before catheter insertion and manipulation, and to disinfect catheter hubs, connectors, and injection ports before accessing the catheter. At present, there are still unresolved questions regarding the best antimicrobial agent for catheter-related bloodstream infection treatment and the duration of concentration stability of the antibiotic solution within the lumen of the port. PMID:24570595
Auxiliadora-Martins, Maria; Apinagés dos Santos, Erick; Adans Wenzinger, Daniel; Alkmim-Teixeira, Gil Cezar; Neto, Gerardo Cristino de M.; Sankarankutty, Ajith Kumar; de Castro e Silva, Orlando; Martins-Filho, Olindo Assis; Basile-Filho, Anibal
2009-01-01
We report a case of a 45-year-old male patient diagnosed with liver cirrhosis by hepatitis C and alcohol, with a Child-Pugh score C and a model for end-stage liver disease (MELD) score of 27, and submitted to liver transplantation. The subject underwent insertion of the pulmonary artery catheter (PAC) in the right internal jugular vein, with technical difficulty concerning catheter advance. There was sudden hypotension, increase in central venous pressure (CVP), and decrease in SvO2 15 minutes after the PAC had been inserted, followed by cardiorespiratory arrest in pulseless electrical activity (PEA), which was promptly assisted with resuscitation. Pericardiocentesis was performed without success, so the individual was subjected to a subxiphoid pericardial window, which led to output of large amounts of blood as well as PEA reversal to sinus rhythm. Sternotomy was performed; rupture of the apex of the right ventricle (RV) was detected, and suture of the site was accomplished. After hemodynamic stabilization, the patient was transferred to the ICU, where he developed septic shock and, despite adequate therapy, died on the eighteenth day after ICU admission. PMID:20066172
Mydlík, M; Derzsiová, K; Rácz, O; Sipulová, A; Lovásová, E
2006-01-01
Oxidative stress, increased lipid peroxidation, and impaired function of antioxidant system may contribute to the accelerated development of atherosclerosis in chronic renal failure patients during renal replacement therapy. The aim of the study was to investigate the influence of oral vitamin E (400 mg/day) in 14 patients who underwent continuous ambulatory peritoneal dialysis (CAPD) and effects of the vitamin E-coated dialyzer in 14 haemodialysis patients on several antioxidant biochemical parameters. Six-week treatment with oral vitamin E in CAPD patients and three-month treatment using vitamin E-coated dialyzer in haemodialysis patients led to the significant decrease of plasma malondialdehyde, to the increase of plasma vitamin E and to the increase of erythrocyte vitamin E in haemodialysis patients. No significant changes of erythrocyte antioxidant enzyme--superoxide dismutase, glutathione peroxidase and catalase were found during the both types of antioxidant therapy. At the end of the third month of haemodialysis study the significant increase of erythrocyte glutathione in haemodialysis patients was found, but that value was significantly lower as normal range. Six-week interruption of the administration of oral vitamin E in CAPD patients led to the significant decrease of erythrocyte superoxide dismutase and plasma vitamin E. Ten-week interruption of the use of vitamin E-coated dialyzer led to the significant increase of plasma malondialdehyde and to the decrease of plasma and erythrocyte vitamin E in haemodialysis patients, near to the values at the beginning of the study. Our study confirmed the beneficial effect of oral administration of vitamin E and the use of vitamin E-coated dialyzer against oxidative stress in CAPD and haemodialysis patients.
Nowak, Zbigniew; Laudański, Krzysztof
2014-01-01
The aim of the study was to use the appraisal model of stress to compare hemodialysis (HD) and continuous peritoneal dialysis (CAPD) patients with special focus on the perception of end-stage renal disease and subsequent emotional profile and health related quality of life (HQoL) in. We hypothesize that different circumstances related to both modes of therapies will result in dissimilar perception of chronic illness with subsequent changes in emotional profile and heath related quality of life. The total of 88 patients with end stage renal disease (ESRD) enrolled in hemodialysis (n=52; HD) or continuous peritoneal dialysis (n=36; CAPD) were given a battery of psychological tests: The Profile of Mood States, The Nottingham Health Profile, The Stress Situation Assessment Questionnaire, The Social Appreciation Questionnaire and The Situation and Trait and Anxiety Inventory. All patients perceived ESRD in terms of a loss and a threat. Moreover, CAPD patients evaluated ESRD as a challenge. Despite different perception of ESRD no significant difference in the level of fear, anxiety or emotional profile was found. Both HD and CAPD patient were reported more fatigue/inertia and confusion/bewilderment than control groups. The main health related complaints were similar in both ESRD patients with major complaints of sleeping disturbances, motor limitations and lack of energy. From the psychological point of view, CAPD treatment seems more like challenge to the enrolled patient which is positive outcome. Despite different appraisal of stress mood and health related complaints were similar in both groups. This may be a result of optimal regulation of cognitive perception of the stress depending on the circumstances of therapy.
Nowak, Zbigniew; Laudański, Krzysztof
2014-01-01
The aim of the study was to use the appraisal model of stress to compare hemodialysis (HD) and continuous peritoneal dialysis (CAPD) patients with special focus on the perception of end-stage renal disease and subsequent emotional profile and health related quality of life (HQoL) in. We hypothesize that different circumstances related to both modes of therapies will result in dissimilar perception of chronic illness with subsequent changes in emotional profile and heath related quality of life. The total of 88 patients with end stage renal disease (ESRD) enrolled in hemodialysis (n=52; HD) or continuous peritoneal dialysis (n=36; CAPD) were given a battery of psychological tests: The Profile of Mood States, The Nottingham Health Profile, The Stress Situation Assessment Questionnaire, The Social Appreciation Questionnaire and The Situation and Trait and Anxiety Inventory. All patients perceived ESRD in terms of a loss and a threat. Moreover, CAPD patients evaluated ESRD as a challenge. Despite different perception of ESRD no significant difference in the level of fear, anxiety or emotional profile was found. Both HD and CAPD patient were reported more fatigue/inertia and confusion/bewilderment than control groups. The main health related complaints were similar in both ESRD patients with major complaints of sleeping disturbances, motor limitations and lack of energy. From the psychological point of view, CAPD treatment seems more like challenge to the enrolled patient which is positive outcome. Despite different appraisal of stress mood and health related complaints were similar in both groups. This may be a result of optimal regulation of cognitive perception of the stress depending on the circumstances of therapy. PMID:24516354
Wieczorowska-Tobis, Katarzyna; Brelinska, Renata; Witowski, Janusz; Passlick-Deetjen, Jutta; Schaub, Thomas P; Schilling, Holger; Breborowicz, Andrzej
2004-01-01
Acidic pH and the presence of glucose degradation products (GDP) are believed to compromise the biocompatibility of peritoneal dialysis fluids (PDF). The present study examines the effects of long-term exposure to GDP and low pH by comparing conventional PDF and a new, neutral pH, low GDP solution. All experiments were performed using a chronic infusion model of dialysis in nonuremic rats. The animals were treated for 6 weeks with 2 daily injections of 4.25% glucose-containing PDF. The following PDF were tested: CAPD3 (single-chamber bag, low pH, high GDP), CAPD3 pH 7.4 (single-chamber bag, neutral pH, high GDP), CAPD3-Balance (double-chamber bag, neutral pH, low GDP). All test solutions were obtained from Fresenius Medical Care, Bad Homburg, Germany. After 6 weeks of exposure, peritoneal permeability to water, urea, creatinine, glucose, and sodium, assessed by peritoneal equilibration test, was similar in all groups. However, compared to other PDF, dialysis with CAPD3-Balance was associated with reduced concentrations of protein and hyaluronan in the dialysate, decreased peritoneal eosinophilia, and reduced dialysate levels of chemokines CCL2/MCP-1 and CCL5/RANTES. Morphologic changes in the peritoneal membrane of CAPD3-Balance-treated animals were much less pronounced and included reduced vascular density, preservation of the mesothelial monolayer and intercellular junction, and no reduplication of the submesothelial basement membrane. A new generation of PDF with physiologic pH and low GDP level produce less irritation to the peritoneal membrane and better preserve its structural integrity. This effect seems to be related predominantly to minimized GDP concentrations.
Kotsar, Andres; Isotalo, Taina; Juuti, Hanne; Mikkonen, Joonas; Leppiniemi, Jenni; Hänninen, Venla; Kellomäki, Minna; Talja, Martti; Tammela, Teuvo L J
2009-03-01
To evaluate, in a pilot study, the efficacy and safety of combining a braided poly(lactic-co-glycolic acid) (PLGA, a copolymer of l-lactide and glycolide) urethral stent and dutasteride in the treatment of acute urinary retention (AUR) due to benign prostatic enlargement (BPE). Ten men with AUR due to BPE were treated as outpatients. A biodegradable braided PLGA urethral stent was inserted into the prostatic urethra, using a specially designed insertion device under visual control. Dutasteride treatment was started and the patients were followed up for 3 months after insertion of the stents. In all patients the stents were placed successfully with the new insertion device. All men were able to void after inserting the stent. At 1 month five patients voided freely with a low residual urine volume (<150 mL), two voided but had a high residual urine volume and a suprapubic catheter was placed, and three needed a suprapubic or an indwelling catheter before 1 month, due to AUR or comorbidities. At 3 months five patients were voiding with no problems. We have developed a new and effective insertion device for biodegradable braided prostatic stents. The new braided-pattern stent overcomes the earlier problems of migration and sudden breakage into large particles associated with biodegradable spiral stents. However, the mechanical properties of the new stent need to be improved and tested in a longer follow-up. We consider that this new biodegradable braided-pattern urethral stent could provide a new option in the future treatment of AUR.
Barriers and Facilitators to Central Venous Catheter Insertion: A Qualitative Study.
Cameron, Kenzie A; Cohen, Elaine R; Hertz, Joelle R; Wayne, Diane B; Mitra, Debi; Barsuk, Jeffrey H
2018-03-14
The aims of the study were to identify perceived barriers and facilitators to central venous catheter (CVC) insertion among healthcare providers and to understand the extent to which an existing Simulation-Based Mastery Learning (SBML) program may address barriers and leverage facilitators. Providers participating in a CVC insertion SBML train-the-trainer program, in addition to intensive care unit nurse managers, were purposively sampled from Veterans Administration Medical Centers located in geographically diverse areas. We conducted semistructured interviews to assess perceptions of barriers and facilitators to CVC insertion. Deidentified transcripts were analyzed using a grounded theory approach and the constant comparative method. We subsequently mapped identified barriers and facilitators to our SBML curriculum to determine whether or not the curriculum addresses these factors. We interviewed 28 providers at six Veterans Administration Medical Centers, identifying the following five overarching factors of perceived barriers to CVC insertion: (1) equipment, (2) personnel/staff, (3) setting or organizational context, (4) patient or provider, and (5) time-related barriers. Three overarching factors of facilitators emerged: (1) equipment, (2) personnel, and (3) setting or organizational context facilitators. The SBML curriculum seems to address most identified barriers, while leveraging many facilitators; building on the commonly identified facilitator of nursing staff contribution by expanding the curriculum to explicitly include nurse involvement could improve team efficiency and organizational culture of safety. Many identified facilitators (e.g., ability to use ultrasound, personnel confidence/competence) were also identified as barriers. Evidence-based SBML programs have the potential to amplify these facilitators while addressing the barriers by providing an opportunity to practice and master CVC insertion skills.
Pham Dang, Charles; Lelong, Aurélie; Guilley, Jérôme; Nguyen, Jean Michel; Volteau, Christelle; Venet, Guillaume; Perrier, Cyril; Lejus, Corinne; Blanloeil, Yvonnick
2009-01-01
We clinically assessed the electrophysiologic effect of dextrose 5% in water (D5W) and of normal saline (NS) used for expansion of the perineural space before placing a stimulating catheter. We questioned if higher current was required with NS but not with D5W, as has been observed experimentally. This was a prospective randomized double-blind study of ASA I to II patients scheduled for total knee replacement. Patients from 2 hospitals were randomly assigned to receive unidentified injectate D5W (n = 25) or NS (n = 25). The primary outcome was the minimal intensity of stimulation (MIS) recorded before and after 2 and 5 mL of study injectates were flushed through the needle before placing a stimulating catheter for continuous femoral and sciatic nerve blocks. Secondary outcomes included, among other parameters, MIS recorded during placement of stimulating catheters. No difference between groups was found with MIS before injection. However, MIS recorded during neurostimulation via the needle in all blocks was significantly higher after 2 and 5 mL of NS than after D5W. In femoral blocks, MIS recorded during placement of catheters was higher during insertion after NS than after D5W but was not different after reaching the final site, regardless of injectate used. In sciatic blocks, MIS was not different during insertion regardless of injectate but was higher after NS than after D5W after reaching the final site. The current needed to electrostimulate the femoral or sciatic nerve was higher after injection of NS than after D5W.
Kocuria kristinae: a true pathogen in pediatric patients.
Chen, Hsin-Mao; Chi, Hsin; Chiu, Nan-Chang; Huang, Fu-Yuan
2015-02-01
Kocuria kristinae is a Gram-positive microorganism, which has rarely been reported as a pathogen that causes infection in humans. Recently, a few studies had concluded that this pathogen can indeed cause infection in immunocompromised hosts. However, the number of reports on K. kristinae infection in pediatric patients is still relatively limited. Clinical data on pediatric patients who had K. kristinae cells isolated from their blood specimens during the period from January 2008 to May 2012 in a tertiary-care hospital in northern Taiwan were gathered and analyzed. Among 12 patients with K. kristinae cells isolated from their blood specimens, laboratory test results confirmed seven to have K. kristinae bloodstream infection. Six of them were premature babies, and one had acute leukemia. The infections were all healthcare associated. All the six premature babies had clinical presentation of sepsis and were inserted with percutaneous central venous catheters. One patient had two sets of blood culture positive for K. kristinae infection, and two premature patients had two sets of K. kristinae isolated, one from blood culture and the other from catheter tip culture, both of which were done at the same time. The leukemic child was inserted with a Broviac catheter and had K. kristinae isolated from both blood specimen and Broviac catheter. In the remaining five patients, K. kristinae infection was considered to be contaminant because they had only one set of positive blood culture and had other recognized infections. K. kristinae can cause infections in premature babies and immunocompromised pediatric patients using long-term intravenous catheters. Therefore, K. kristinae should be considered as a true pathogen and proper treatment should be provided to all susceptible pediatric patients. Copyright © 2013. Published by Elsevier B.V.
Browne, Ingrid M; Birnbach, David J; Stein, Deborah J; O'Gorman, David A; Kuroda, Maxine
2005-08-01
When using the needle-through-needle combined spinal-epidural (CSE) technique for labor analgesia, failure to obtain cerebrospinal fluid (CSF), paresthesias, and intrathecal or intravascular migration of the catheter are of concern. Epidural needles with spinal needle apertures, such as the back-hole Espocan (ES) needles, are available and may reduce these risks. We describe the efficacy and adverse events associated with a modified epidural needle (ES) versus a conventional Tuohy needle for CSE. One-hundred parturients requesting labor analgesia (CSE) were randomized into 2 groups: 50-ES 18-gauge modified epidural needle with 27-gauge Pencan atraumatic spinal needle, 50-conventional 18-gauge Tuohy needle with 27-gauge Gertie Marx atraumatic spinal needle. Information on intrathecal or intravascular catheter placement, paresthesia on introduction of spinal needle, failure to obtain CSF through the spinal needle after placement of epidural needle, unintentional dural puncture, and epidural catheter function was obtained. No intrathecal catheter placement occurred in either group. Rates of intravascular catheter placement and unintentional dural puncture were similar between the groups. Significant differences were noted regarding spinal needle-induced paresthesia (14% ES versus 42% Tuohy needles, P = 0.009) and failure to obtain CSF on first attempt (8% ES versus 28% Tuohy needles, P < 0.02). Use of ES needles for CSE significantly reduces paresthesia associated with the insertion of the spinal needle and is associated with more frequent successful spinal needle placement on the first attempt. The use of modified epidural needles with a back hole for combined spinal-epidural technique significantly reduces paresthesia associated with the insertion of the spinal needle and is associated with more frequent successful spinal needle placement on the first attempt.
Lanot, Antoine; Lobbedez, Thierry; Bechade, Clémence; Verger, Christian; Fabre, Emmanuel; Dratwa, Max; Vernier, Isabelle
2016-01-01
International guidelines recommend the use of a prophylactic antibiotic before the peritoneal dialysis (PD) catheter can be inserted. The main objective of this study was to assess whether this practice is associated with a lower risk of early peritonitis and to estimate the magnitude of the centre effect. A retrospective, multi-centric study was conducted, in which data from the French Language Peritoneal Dialysis Registry was analysed. Patients were separated into 2 groups based on whether or not prophylactic antibiotics were used prior to catheter placement. Out of the 2,014 patients who had a PD catheter placed between February 1, 2012 and December 31, 2014, 1,105 were given a prophylactic antibiotic. In a classical logit model, the use of prophylactic antibiotics was found to protect the individual against the risk of early peritonitis (OR 0.67, 95% CI 0.49-0.92). However, this association lost significance in a mixed logistic regression model with centre as a random effect: OR 0.73 (95% CI 0.48-1.09). Covariates associated with the risk of developing early peritonitis were age over 65: OR 0.73 (95% CI 0.39-0.85), body mass index over 35 kg/m2: OR 1.99 (95% CI 1.13-3.47), transfer to PD due to graft failure: OR 2.24 (95% CI 1.22-4.11), assisted PD: OR 1.96 (95% CI 1.31-2.93), and the use of the Moncrief technique: OR 3.07 (95% CI 1.85-5.11). There is a beneficial effect of prophylactic antibiotic used prior to peritoneal catheter placement, on the occurence of early peritonitis. However, the beneficial effect could be masked by a centre effect. © 2016 S. Karger AG, Basel.
Chopra, Vineet; Kaatz, Scott; Grant, Paul; Swaminathan, Lakshmi; Boldenow, Tanya; Conlon, Anna; Bernstein, Steven J; Flanders, Scott A
2018-02-01
Catheter exchange over a guidewire is frequently performed for malfunctioning peripherally inserted central catheters (PICCs). Whether such exchanges are associated with venous thromboembolism is not known. We performed a retrospective cohort study to assess the association between PICC exchange and risk of thromboembolism. Adult hospitalized patients that received a PICC during clinical care at one of 51 hospitals participating in the Michigan Hospital Medicine Safety consortium were included. The primary outcome was hazard of symptomatic venous thromboembolism (radiographically confirmed upper-extremity deep vein thrombosis and pulmonary embolism) in those that underwent PICC exchange vs those that did not. Of 23,010 patients that underwent PICC insertion in the study, 589 patients (2.6%) experienced a PICC exchange. Almost half of all exchanges were performed for catheter dislodgement or occlusion. A total of 480 patients (2.1%) experienced PICC-associated deep vein thrombosis. The incidence of deep vein thrombosis was greater in those that underwent PICC exchange vs those that did not (3.6% vs 2.0%, P < .001). Median time to thrombosis was shorter among those that underwent exchange vs those that did not (5 vs 11 days, P = .02). Following adjustment, PICC exchange was independently associated with twofold greater risk of thrombosis (hazard ratio [HR] 1.98; 95% confidence interval [CI], 1.37-2.85) vs no exchange. The effect size of PICC exchange on thrombosis was second in magnitude to device lumens (HR 2.06; 95% CI, 1.59-2.66 and HR 2.31; 95% CI, 1.6-3.33 for double- and triple-lumen devices, respectively). Guidewire exchange of PICCs may be associated with increased risk of thrombosis. As some exchanges may be preventable, consideration of risks and benefits of exchanges in clinical practice is needed. Published by Elsevier Inc.
Szeto, C C; Lai, K N; Yu, A W; Leung, C B; Ho, K K; Mak, T W; Li, P K; Lam, C W
1997-08-01
The usage of three x 2 liter daily exchanges is adopted as the standard CAPD regime in Hong Kong over the last 10 years due to budgetary constraint. This dialysis prescription is considered suboptimal in Western standard. However, the necessity of maintaining Kt/V > 1.7 for CAPD dialysis adequacy is not unanimously agreed. We performed a cross-sectional study of 117 patients on CAPD. Seventy-eight percent of our patients had 3 x 2 liter daily exchange while the rest had 4 daily exchanges. Fifteen percent of patients were diabetic. Patients with Kt/V < 1.7 were similar to those with Kt/V > 1.7 in age, duration of CAPD, BUN, plasma creatinine, albumin, peritonitis rate, and incidence of hypertension. Patients with Kt/V > or = 1.7 had higher hemoglobin, higher nPCR, more residual renal function; and more of them received 4 daily exchanges. Their peritoneal permeability did not differ. Their employment and rehabilitation status was also similar. Our 5-year survival was 79% despite a lower Kt/V. Notably, the protein catabolic rate of our patients was higher than that in Western patients. This is likely due to dietary difference. Our study suggests small-volume dialysis may be acceptable in Asian population with smaller body size given the financial constraint.
McGregor, S J; Brock, J H; Briggs, J D; Junor, B J
1987-01-01
IgG, C3 and transferrin in peritoneal dialysis effluent of patients undergoing continuous ambulatory peritoneal dialysis (CAPD) were 1%-2% of those in serum. In contrast, the values in normal peritoneal fluid were not significantly different from those in serum. The three proteins correlated with each other in peritoneal dialysis effluent, but were independent of the amount in the corresponding patients' sera. There was also an overall inverse correlation between total protein in peritoneal dialysis effluent and time on CAPD during the first 6 months of treatment but not thereafter, which suggests that changes in membrane permeability occur during the early months. In peritoneal dialysis effluent, but not in normal peritoneal fluid, there was a correlation between opsonising capacity and IgG or C3 concentrations. An inverse correlation between opsonic activity of peritoneal dialysis effluent and frequency of peritonitis was also found. Peritoneal dialysis effluent permitted significantly faster multiplication of Staphylococcus epidermidis than sera or normal peritoneal fluid, and the growth rate correlated inversely with the transferrin levels in peritoneal dialysis effluent. Overall IgG, C3 and transferrin in peritoneal dialysis effluent are inadequate for optimal opsonising and bacteriostatic activity, and the peritoneal cavities of CAPD patients are therefore immunocompromised sites.
Robotic positioning of standard electrophysiology catheters: a novel approach to catheter robotics.
Knight, Bradley; Ayers, Gregory M; Cohen, Todd J
2008-05-01
Robotic systems have been developed to manipulate and position electrophysiology (EP) catheters remotely. One limitation of existing systems is their requirement for specialized catheters or sheaths. We evaluated a system (Catheter Robotics Remote Catheter Manipulation System [RCMS], Catheter Robotics, Inc., Budd Lake, New Jersey) that manipulates conventional EP catheters placed through standard introducer sheaths. The remote controller functions much like the EP catheter handle, and the system permits repeated catheter disengagement for manual manipulation without requiring removal of the catheter from the body. This study tested the hypothesis that the RCMS would be able to safely and effectively position catheters at various intracardiac sites and obtain thresholds and electrograms similar to those obtained with manual catheter manipulation. Two identical 7 Fr catheters (Blazer II; Boston Scientific Corp., Natick, Massachusetts) were inserted into the right femoral veins of 6 mongrel dogs through separate, standard 7 Fr sheaths. The first catheter was manually placed at a right ventricular endocardial site. The second catheter handle was placed in the mating holder of the RCMS and moved to approximately the same site as the first catheter using the Catheter Robotics RCMS. The pacing threshold was determined for each catheter. This sequence was performed at 2 right atrial and 2 right ventricular sites. The distance between the manually and robotically placed catheters tips was measured, and pacing thresholds and His-bundle recordings were compared. The heart was inspected at necropsy for signs of cardiac perforation or injury. Compared to manual positioning, remote catheter placement produced the same pacing threshold at 7/24 sites, a lower threshold at 11/24 sites, and a higher threshold at only 6/24 sites (p > 0.05). The average distance between catheter tips was 0.46 +/- 0.32 cm (median 0.32, range 0.13-1.16 cm). There was no difference between right atrial and right ventricular sites (p > 0.05). His-bundle electrograms were equal in amplitude and timing. Further, the remote navigation catheter was able to be disengaged, manually manipulated, then reengaged in the robot without issue. There was no evidence of perforation. The Catheter Robotics remote catheter manipulation system, which uses conventional EP catheters and introducer sheaths, appears to be safe and effective at directing EP catheters to intracardiac sites and achieving pacing thresholds and electrograms equivalent to manually placed catheters. Further clinical studies are needed to confirm these observations.
Peripherally Inserted Central Catheter Use in Skilled Nursing Facilities: A Pilot Study.
Chopra, Vineet; Montoya, Ana; Joshi, Darius; Becker, Carol; Brant, Amy; McGuirk, Helen; Clark, Jordyn; Harrod, Molly; Kuhn, Latoya; Mody, Lona
2015-09-01
To describe patterns of use, care practices, and outcomes related to peripherally inserted central catheter (PICC) use in skilled nursing facilities (SNFs). Prospective cohort study. Two community SNFs. Adult SNF residents with PICCs (N = 56). Information on indication for PICC use, device characteristics (e.g., lumens, gauge), and participant data (comorbidities, medications) were obtained from medical records. Care practices (e.g., frequency of flushing, dressing care) and problems related to PICCs were recorded. Major (central line-associated bloodstream infection, venous thromboembolism, catheter dislodgement) and minor (migration, dressing disruption, lumen occlusion, exit site infection) complications and process measures (flushing of PICC, assessment of necessity) were recorded. Bivariate analyses with t-tests, chi-square tests, or Fischer exact tests were used for continuous and categorical data. Participants were enrolled from two SNFs. The most common indication for PICC use was intravenous antibiotic delivery. The average PICC dwell time was 43 days, and most devices were single-lumen PICCs. Major and minor complications were common and occurred in 11 (20%) and 18 (32%) participants, respectively. Occlusion (23%, n = 13), accidental dislodgement (12%, n = 7), and dressing disruption (11%, n = 6) were the commonest complications observed. Documentation regarding catheter care practices occurred in 41% of cases. Quality improvement efforts that seek to benchmark practice, identify gaps, and institute efforts to improve PICC care and practice in SNFs appear necessary. © 2015, Copyright the Authors Journal compilation © 2015, The American Geriatrics Society.
What Happens in the Emergency Room?
... all of this information is recorded in the computer and saved. injection: a shot IV: intravenous catheter, which is a thin plastic tube inserted into your vein to give you medicine papoose: a soft board with Velcro straps that ...
... or blood pooling where the catheter is inserted Blood clot that goes to arteries in your leg, heart, ... cooking oils Cholesterol and lifestyle Controlling your high blood pressure Dietary fats explained Fast food tips Heart attack - discharge Heart disease - risk factors ...
... to assess your condition. You will be positioned on the examining table. You may be connected to monitors that track your heart rate, blood pressure and pulse during the procedure. A nurse or technologist will insert an intravenous (IV) line into a ...
Catheter-Directed Thrombolysis
... in the operating room. You will be positioned on the examining table. You may be connected to monitors that track your heart rate, blood pressure and pulse during the procedure. A nurse or technologist will insert an intravenous (IV) line into a ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cookson, Daniel, E-mail: danielthomascookson@yahoo.co.uk; Caldwell, Stuart, E-mail: stuart.caldwell@middlemore.co.nz
Phlegmasia caerulea dolens (PCD) is a potentially disastrous complication of inferior vena cava filter insertion, and its optimum management has not been clearly established. We present a case report of a patient with pulmonary embolism and acute adrenal haemorrhage who developed PCD secondary to massive iliocaval thrombosis after insertion of a Cook Celect removable filter. Local intravenous catheter-directed thrombolysis (CDT), followed by systemic anticoagulation, achieved limb salvage and virtual resolution of symptoms at 3 months without complications. CDT can be a successful primary treatment of filter-associated PCD and can be safe in selected patients with acute nontraumatic haemorrhage. Systemic anticoagulationmore » may subsequently restore complete venous patency and may therefore be a useful approach to postthrombolysis management of residual iliocaval thrombus when filter removal is indicated.« less
Jardim, Jaquelline Maria; Lacerda, Rúbia Aparecida; Soares, Naury de Jesus Danzi; Nunes, Bruna Kosar
2013-02-01
The aim of this study was to observe clinical procedures in order to evaluate the practices used for the control and prevention of bloodstream infections associated with short-term central venous catheters (BSI-ACVC). The study data came from 5877 assessments distributed among selected practices. The results revealed the following adherence rates among the practices selected: 91.6% for recording the indication and permanence time of the CVC, 51.5% for adhering to the care and maintenance of the dressing at the CVC insertion site and its devices, 10.7% for hand hygiene practices while performing procedures related to the CVC, and 0.0% for the practices related to the insertion of the central venous catheter (CVC). The results demonstrate the need for further elaboration of strategies that ensure sustainable compliance practices for prevention and control BSI-ACVC in the institution being assessed.
Complete endoscopic management of a retained bullet in the bladder.
Friedman, Ariella A; Trinh, Quoc-Dien; Kaul, Sanjeev; Bhandari, Akshay
2013-01-01
A 25-year-old male gunshot victim presented at our institution with gross hematuria following Foley catheter insertion. Computed tomography and cystogram did not show a bladder perforation, but were notable for a left ischial fracture and the presence of a bullet within the bladder. After failed attempts at retrieving the bullet with a resectoscope and loop, as well as a cystoscope and stone crusher, a 26 French nephroscope was inserted transurethrally, and the bullet was successfully engaged and removed using a Perc NCircle (Cook Medical, Bloomington, IN) grasper. The extra-peritoneal injury was managed conservatively with catheter drainage. To our knowledge, this represents the first case of successful transurethral management of a retained intravesical bullet. Such an approach may benefit patients with retained intravesical bullets or other challenging intravesical foreign bodies and may be helpful in select circumstances to spare patients from more extensive surgeries.
Sebastian, Raul; Ghanem, Omar; Diroma, Frank; Milner, Stephen M; Gerold, Kevin B; Price, Leigh A
2015-05-01
Multiple factors place burn patients at a high risk of pneumothorax development. Currently, no specific recommendations for the management of pneumothorax in large total body surface area (TBSA) burn patients exist. We present a case of a major burn patient who developed pneumothorax after central line insertion. After the traditional large bore (24 Fr) chest tube failed to resolve the pneumothorax, the pneumothorax was ultimately managed by a percutaneous placed pigtail catheter thoracostomy placement and resulted in its complete resolution. We will review the current recommendations of pneumothorax treatment and will highlight on the use of pigtail catheters in pneumothorax management in burn patients. Copyright © 2014 Elsevier Ltd and ISBI. All rights reserved.
Extravasation injuries in adults.
Al-Benna, S; O'Boyle, C; Holley, J
2013-01-01
Insertion of an intravascular catheter is one of the most common invasive procedures in hospitals worldwide. These intravascular lines are crucial in resuscitation, allow vital medication to be administered, and can be used to monitor the patients' real-time vital parameters. There is, however, growing recognition of potential risks to life and limb associated with their use. Medical literature is now replete with isolated case reports of complications succinctly described by Garden and Laussen (2004) as "An unending supply of "unusual" complications from central venous catheters." This paper reviews complications of venous and arterial catheters and discusses treatment approaches and methods to prevent complications, based on current evidence and endeavours to provide information and guidance that will enable practitioners to prevent, recognise, and successfully treat extravasation injuries in adults.
Detection of an embolized central venous catheter fragment with endobronchial ultrasound.
Dhillon, Samjot Singh; Harris, Kassem; Alraiyes, Abdul H; Picone, Anthony L
2018-01-01
An 84-year-old woman underwent Convex-probe Endobronchial Ultrasound (CP-EBUS) for 18 F-fluorodeoxyglucose avid subcarinal lymphadenopathy on Positron Emission Tomogram (PET) scan. Endobronchial ultrasound-guided transbronchial needle aspiration of the subcarinal lymph node revealed squamous cell lung carcinoma. A small hyperechoic rounded density was noted inside the lumen of the azygous vein. Based on chest computed tomography findings and her clinical history, this was felt to be a broken fragment of a peripherally inserted central catheter, which was placed for intravenous antibiotics, a few months prior to this presentation. To the best of our knowledge, this is the first ever CP-EBUS description of a broken fragment of central venous catheter. © 2016 John Wiley & Sons Ltd.
[Anesthesia and lumbar epidural anesthesia in an infant with third-degree burns].
Arqués Teixidor, P; Maged Mabrok, M; Marco Valls, J; Moral García, V
1989-01-01
Epidural route is widely used in adults for injection of drugs, but it is not so often used in pediatric patients. We present the case of a 8 month old burned infant who received anesthesia and analgesia through a lumbar epidural catheter. The insertion of epidural catheter is described. Two surgical procedures were performed under epidural anesthesia with 0.5% bupivacaine an epinephrine 1:200.000 (2.5 mg/kg). 16 hours of postoperative analgesia was obtained with epidural morphine (0.05 mg/kg). No side effects were seen. We analyze the uses of epidural anesthesia in pediatric patients, the catheter care in the burned child, the hemodynamic changes observed during anesthesia and the results of peridural morphine.
Sundaram, C P; Saltzman, B
1998-10-01
We describe a simple method to assist stone localization during shock wave lithotripsy in the presence of a Double J stent. A 4F whistle tip ureteral catheter is passed alongside a previously inserted 6F Double J stent. The tip of the ureteral stent is positioned in the lower or mid third of the ureter. Contrast material is injected through the ureteral catheter during lithotripsy to assist stone localization. This technique has been successful in localization of poorly opacified renal stones during lithotripsy. Radiolucent and poorly calcified renal stones can be easily localized during shock wave lithotripsy, despite the presence of a Double J stent. No special catheters or stents are required for this technique.
Ablordeppey, Enyo A; Drewry, Anne M; Beyer, Alexander B; Theodoro, Daniel L; Fowler, Susan A; Fuller, Brian M; Carpenter, Christopher R
2017-04-01
We performed a systematic review and meta-analysis to examine the accuracy of bedside ultrasound for confirmation of central venous catheter position and exclusion of pneumothorax compared with chest radiography. PubMed, Embase, Cochrane Central Register of Controlled Trials, reference lists, conference proceedings and ClinicalTrials.gov. Articles and abstracts describing the diagnostic accuracy of bedside ultrasound compared with chest radiography for confirmation of central venous catheters in sufficient detail to reconstruct 2 × 2 contingency tables were reviewed. Primary outcomes included the accuracy of confirming catheter positioning and detecting a pneumothorax. Secondary outcomes included feasibility, interrater reliability, and efficiency to complete bedside ultrasound confirmation of central venous catheter position. Investigators abstracted study details including research design and sonographic imaging technique to detect catheter malposition and procedure-related pneumothorax. Diagnostic accuracy measures included pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio. Fifteen studies with 1,553 central venous catheter placements were identified with a pooled sensitivity and specificity of catheter malposition by ultrasound of 0.82 (0.77-0.86) and 0.98 (0.97-0.99), respectively. The pooled positive and negative likelihood ratios of catheter malposition by ultrasound were 31.12 (14.72-65.78) and 0.25 (0.13-0.47). The sensitivity and specificity of ultrasound for pneumothorax detection was nearly 100% in the participating studies. Bedside ultrasound reduced mean central venous catheter confirmation time by 58.3 minutes. Risk of bias and clinical heterogeneity in the studies were high. Bedside ultrasound is faster than radiography at identifying pneumothorax after central venous catheter insertion. When a central venous catheter malposition exists, bedside ultrasound will identify four out of every five earlier than chest radiography.
Previous PICC Placement May Be Associated With Catheter-Related Infections in Hemodialysis Patients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Butler, Philip J., E-mail: philip.butler@yale.edu; Sood, Shreya; Mojibian, Hamid
2011-02-15
Background: Catheter-related infections (CRIs) are a significant source of morbidity and mortality in hemodialysis patients. The identification of novel, modifiable risk factors for CRIs may lead to improved outcomes in this population. Peripherally inserted central catheters (PICCs) have been hypothesized to compromise vascular access due to vascular damage and venous thrombosis, whereas venous thrombosis has been linked to the development of CRIs. Here we examine the association between PICC placement and CRIs. Methods: A retrospective review was performed of all chronic hemodialysis catheter placements and exchanges performed at a large university hospital from September 2003 to September 2008. History ofmore » PICC line use was determined by examining hospital radiologic records from December 1993 to September 2008. Catheter-related complications were assessed and correlated with PICC line history. Results: One hundred eighty-five patients with 713 chronic tunneled hemodialysis catheter placements were identified. Thirty-eight of those patients (20.5%) had a history of PICC placement; these patients were more likely to have CRIs (odds ratio = 2.46, 95% confidence interval = 1.71-3.53, p < .001) compared with patients without a history of PICC placement. There was no difference between the two groups in age or number of catheters placed. Conclusion: Previous PICC placement may be associated with catheter-related infections in hemodialysis patients.« less
Frigerio, Simona; Di Giulio, Paola; Gregori, Dario; Gavetti, Dario; Ballali, Simonetta; Bagnato, Silvia; Guidi, Gabriella; Foltran, Francesca; Renga, Giovanni
2012-04-01
Until now, the evaluation of the effectiveness of guideline implementation in nursing and allied health professions has received relatively little attention. The aims of this study were (i) to describe the development process of guidelines concerning the management of peripheral venous catheters (PVCs) implemented in an Italian hospital; and (ii) to evaluate the effectiveness of guideline dissemination in terms of both clinical outcomes (signs of infection) and process outcomes (measures of appropriateness of PVC management). An observational study was conducted before and after the adoption of a new protocol in the CTO-CRF-Maria Adelaide Hospital. Data from 306 PVCs (153 before and 153 after) were collected. For each PVC, a wide range of outcome measures was collected, including: data on fixation system type of dressing; visibility of the insertion site; registration of the insertion date; duration of catheter insertion; presence of connectors, taps and needles; and signs of infection. The effect of guideline implementation was evaluated using a logistic regression model to adjust for the confounding variable represented by the nurses' average years of working experience. The risk of using inappropriate dressing was significantly reduced [odds ratio (OR) 0.43; 95% confidence interval (CI) 0.27-0.70], while the use of transparent dressing increased (OR 2.39; 95% CI 1.46-3.89). Our study shows significant improvement in practices relevant to the correct management of PVCs 2 months after guideline implementation. A second survey (after a minimum of 6 months) is necessary to assess persistence of improvement in clinical practices. © 2010 Blackwell Publishing Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matsumoto, Tomohiro, E-mail: t-matsu@tokai-u.jp; Mine, Takahiko, E-mail: mine@tsc.u-tokai.ac.jp; Hayashi, Toshihiko, E-mail: t.hayashi@tokai.ac.jp
PurposeTo retrospectively describe the feasibility and efficacy of CT fluoroscopy-guided transsacral intervertebral drainage for pyogenic spondylodiscitis at the lumbosacral junction with a combination of two interventional radiological techniques—CT-guided bone biopsy and abscess drainage.Materials and methodsThree patients with pyogenic spondylodiscitis at the lumbosacral junction were enrolled in this study between July 2013 and December 2015. The procedure of CT fluoroscopy-guided transsacral intervertebral drainage for pyogenic spondylodiscitis at the lumbosacral junction was as follows: the sacrum at S1 pedicle was penetrated with an 11-gauge (G) bone biopsy needle to create a path for an 8-French (F) pigtail drainage catheter. The bone biopsymore » needle was withdrawn, and an 18-G needle was inserted into the intervertebral space of the lumbosacral junction. Then, a 0.038-inch guidewire was inserted into the intervertebral space. Finally, the 8-F pigtail drainage catheter was inserted over the guidewire until its tip reached the intervertebral space. All patients received six-week antibiotics treatment.ResultsSuccessful placement of the drainage catheter was achieved for each patient without procedural complications. The duration of drainage was 17–33 days. For two patients, specific organisms were isolated; thus, definitive medical therapy was possible. All patients responded well to the treatment.ConclusionsCT fluoroscopy-guided transsacral intervertebral drainage for pyogenic spondylodiscitis at the lumbosacral junction is feasible and can be effective with a combination of two interventional techniques—CT fluoroscopy-guided bone biopsy and abscess drainage.« less
Emergency cricothyrotomy-a comparative study of different techniques in human cadavers.
Schober, Patrick; Hegemann, Martina C; Schwarte, Lothar A; Loer, Stephan A; Noetges, Peter
2009-02-01
Emergency cricothyrotomy is the final lifesaving option in "cannot intubate-cannot ventilate" situations. Fast, efficient and safe management is indispensable to reestablish oxygenation, thus the quickest, most reliable and safest technique should be used. Several cricothyrotomy techniques exist, which can be grouped into two categories: anatomical-surgical and puncture. We studied success rate, tracheal tube insertion time and complications of different techniques, including a novel cricothyrotomy scissors technique in human cadavers. Sixty-three inexperienced health care providers were randomly assigned to apply either an anatomical-surgical technique (standard surgical technique, n=18; novel cricothyrotomy scissors technique, n=14) or a puncture technique (catheter-over-needle technique, n=17; wire-guided technique, n=14). Airway access was almost always successful with the anatomical-surgical techniques (success rate in standard surgical group 94%, scissors group 100%). In contrast, the success rate was smaller (p<0.05) with the puncture techniques (catheter-over-needle group 82%, wire-guided technique 71%). Tracheal tube insertion time was faster overall (p<0.05) with anatomical-surgical techniques (standard surgical 78s [54-135], novel cricothyrotomy scissors technique 60s [42-82]; median [IQR]) than with puncture techniques (catheter-over-needle technique 74s [48-145], wire-guided technique 135s [116-307]). We observed fewer complications with anatomical-surgical techniques than with puncture techniques (p<0.001). In inexperienced health care personnel, anatomical-surgical techniques showed a higher success rate, a faster tracheal tube insertion time and a lower complication rate compared with puncture techniques, suggesting that they may be the techniques of choice in emergencies.
Momin, Eric N; Recinos, Pablo F; Coon, Alexander L; Rigamonti, Daniele
2010-06-01
Ventriculoatrial (VA) shunting is commonly used to treat hydrocephalus when ventriculoperitoneal shunting has failed. Placement of a VA shunt in patients with narrowing or occlusion of the central veins presents considerable difficulty because few imaging modalities exist to safely and reliably insert a guidewire or atrial catheter past the occlusion. We report the use of intraoperative venography to guide the placement of the distal portion of a VA shunt in a patient with a valve blocking the left brachiocephalic vein. A 42-year-old man with pseudotumor cerebri and a left ventriculoperitoneal shunt presented with severe headaches. He was diagnosed with partial distal shunt obstruction. Because of a history of failed attempts at ventriculoperitoneal shunting, conversion to a VA shunt via the left internal jugular vein was planned. Surgery was performed by using the standard technique until resistance was encountered when inserting a guidewire into the internal jugular vein. Intraoperative venography of the central veins was performed, which showed a large valve blocking progression of the guidewire in the left brachiocephalic vein. Using fluoroscopic guidance, a 0.035-inch guidewire was successfully directed through the vein past the obstruction and exchanged for a peel-away introducer. The distal shunt catheter was then inserted, and the correct position in the atrium was confirmed fluoroscopically. When obstruction of the central veins is found during a VA shunting procedure, intraoperative venography is a useful method to aid in the placement of the atrial catheter through the central veins.
Ribeiro, A F; Neto, I S; Maia, I; Dias, C
2018-04-19
Central venous catheters are widely used in critically ill patients; however, they are also associated with increased morbidity and mortality. The literature may underestimate the incidence of catheter-inducible right atrial thrombi that are asymptomatic but potentially life threatening. The recognized risk factors for its development include infections related to the catheter, endothelial injury secondary to mechanical and chemical damage induced by certain medications and infused fluids. The characteristics of the patient and the catheter, such as size, material, type, location and ease of insertion, as well as the duration of placement play an additional role. We report the case of a 38-year-old man, who developed an asymptomatic catheter-inducible right atrial thrombi requiring open heart surgery, after taking a central venous catheter for thirty-five days. The present case highlights existing limitations in making a correct and fast diagnosis, which should be anticipated in patients with multiple risk factors for thrombosis. Given the limited recommendations available, we consider that the most appropriate strategy should be individualized. Copyright © 2018 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.
NASA Astrophysics Data System (ADS)
Gare, Aya
2013-11-01
Catheter-Associated Urinary Tract Infection (CAUTI) is the most common nosocomial infection in the U.S. healthcare system. The obstruction of urine caused by confined air bubbles result in the development of urinary back-flow and stagnation, wherein microbial pathogens could multiply rapidly and colonization within catheters become commonplace. Infections can be prevented by aseptic insertion and the maintenance of a closed drainage system, keeping high infection control standards, and preventing back-flow from the catheter bag. The goal of this study is to assess the effectiveness of a simple, low cost, modification that may be implemented into current catheter designs to reduce the incidence of CAUTI. Using the principle of transmission of fluid-pressure and the Young-Laplace equation for capillary pressure difference, this research focuses on improving the liquid flow in the presence of confined bubbles to prevent stagnation and reflux of bacteria-ridden urine into the body. Preliminary experiments are performed on a variety of tubes with hydrophobic-coating the interior, as well as geometrically modifying the tubes. Proof-of-Concept Prototype tubes are used to represent the drainage system of the catheter structure.
Ozkaraman, Ayse; Yesilbalkan, Öznur Usta
2016-04-01
Complications may occur in the subcutaneous or subdermal tissues during IV administration of chemotherapy related to blood flow and catheter placement. Daily isometric hand grip exercises were evaluated for their effect on blood flow in the vessels of the nondominant arm before placement of IV catheters and the success rate of IV catheter placement on the first attempt. The study focused on patients with non-Hodgkin lymphoma receiving the first and second cycles of chemotherapy. The intervention group performed daily isometric hand grip exercises before chemotherapy with peripheral catheter insertion. The control group performed routine activities only. Blood flow was measured by ultrasound in the brachial artery (BA) and brachial vein (BV) of the nondominant arm before the first (T1) and second (T2) cycles of chemotherapy. Blood flow slightly increased in the intervention group at T2 compared to T1. In the control group, blood flow decreased in the BA and did not change in the BV at T2 compared to T1. The success rate for first-attempt placement of a peripheral IV catheter was the same for the intervention and control groups.
Elsharkawy, Hesham; Sonny, Abraham; Govindarajan, Srinivasa Raghavan; Chan, Vincent
2017-05-01
Epidural anesthesia and analgesia has a reported failure rate ranging from 13% to 32%. We describe a technique using colour Doppler and M-mode ultrasonography to determine the position of the epidural catheter after placement in adults. This retrospective review included 37 adult patients who received postoperative epidural analgesia and underwent technically difficult epidural catheter placement. The demographic characteristics, type of surgery, use of ultrasonography, method of insertion, intervertebral level, and success of epidural localization using colour Doppler were noted for each patient. Pain scores on postoperative day 1 and the presence of a patchy block were also reviewed. Colour Doppler study helped to indicate the catheter's path from the skin to the epidural space during saline injection in 33 patients (89%). Saline flow within the epidural space (catheter tip confirmation) was successfully detected with colour Doppler in 25 patients (67.5%) and with M-mode ultrasonography in 28 patients (75%). Appropriate dermatomal analgesia was noted in 35 patients (94.5%) during local anesthetic infusion. Our preliminary data suggest the feasibility of using colour Doppler and M-mode ultrasonography to confirm proper epidural catheter placement.
Experience with the bonanno catheter in the management of OHSS from IVF-ET Cycles.
Okohue, J E; Oriji, V K; Ikimalo, J I
2017-07-01
To document our experience with the use of the Bonanno catheter as a closed abdominal drain for OHSS Methods: A retrospective study of all IVF embryo transfer (ET) treatment cycles carried out between May 2006 and April 2009 at a dedicated IVF centre. Case notes of patients with OHSS were retrieved and the outcome of the continuous closed abdominal drain with Bonanno catheter documented. Within the period under review, 234 patients had controlled ovarian stimulation with ultrasound guided egg retrieval. Two hundred and twenty eight (228) got to the stage of embryo transfer with 72 clinical pregnancies. The clinical pregnancy rate was 31.58%. Fourteen (6%) of those who were stimulated developed OHSS and had a closed abdominal drain of the ascitic fluid using the Bonanno catheter. The average number of days of the abdominal drainage was 7.5days and the average volume of ascitic fluid drained from a patient per day was 2454.9 + 748mls. Eight (8) patients who had OHSS achieved clinical pregnancy (six intrauterine, one ectopic and one heterotopic pregnancies), giving a clinical pregnancy rate of 57.14% in patients with OHSS. Four patients had blocked Bonanno catheters and three of them had the catheter changed while the fourth had the catheter successfully flushed. Four patients had the insertion site dressing changed due to soaking with ascitic fluid. There was no incidence of injury to intra abdominal organs or broken catheter. Bonanno Catheter is both effective and safe in draining ascitic fluid following OHSS.
Empyema and effusion: outcome of image-guided small-bore catheter drainage.
Keeling, A N; Leong, S; Logan, P M; Lee, M J
2008-01-01
Empyema and complicated pleural effusion represent common medical problems. Current treatment options are multiple. The purpose of this study was to access the outcome of image-guided, small-bore catheter drainage of empyema and effusion. We evaluated 93 small-bore catheters in 82 patients with pleural effusion (n = 30) or empyema (n = 52), over a 2-year period. Image guidance was with ultrasound (US; n = 56) and CT (n = 37). All patients were followed clinically, with catheter dwell times, catheter outcome, pleural fluid outcome, reinsertion rates, and need for urokinase or surgery recorded. Ninety-three small-bore chest drains (mean=10.2 Fr; range, 8.2-12.2 Fr) were inserted, with an average dwell time of 7.81 days for empyemas and 7.14 days for effusions (p > 0.05). Elective removal rates (73% empyema vs 86% effusions) and dislodgement rates (12% empyema vs 13% effusions) were similar for both groups. Eight percent of catheters became blocked and 17% necessitated reinsertion in empyemas, with no catheters blocked or requiring reinsertion in effusions (p < 0.05). Thirty-two patients (51%) required urokinase in the empyema group, versus 2 patients (6%) in the effusion group (p < 0.05). All treatment failures, requiring surgery, occurred in the empyema group (19%; n = 12; p < 0.05). In conclusion, noninfected pleural collections are adequately treated with small-bore catheters, however, empyemas have a failure rate of 19%. The threshold for using urokinase and larger-bore catheters should be low in empyema.
Stickler, D J; Morgan, S D
2008-08-01
The care of many patients undergoing long-term bladder catheterisation is complicated when the flow of urine through the catheter is blocked by encrustation. The problem results from infection by urease-producing bacteria, especially Proteus mirabilis, and the subsequent formation of crystalline biofilms on the catheter. The aim of this study was to discover how P. mirabilis initiates the development of these crystalline biofilms. The early stages in the formation of the biofilms were observed on a range of Foley catheters in a laboratory model of the catheterised bladder. Scanning electron micrographs revealed that when all-silicone, silicone-coated latex, hydrogel-coated latex, hydrogel/silver-coated latex and nitrofurazone silicone catheters were inserted into bladder models containing P. mirabilis and alkaline urine, their surfaces were rapidly coated with a microcrystalline foundation layer. X-ray microanalysis showed that this material was composed of calcium phosphate. Bacterial colonisation of the foundation layer followed and by 18h the catheters were encrusted by densely populated crystalline P. mirabilis biofilms. These observations have important implications for the development of encrustation-resistant catheters. In the case of silver catheters for example, bacterial cells can attach to the crystalline foundation layer and continue to grow, protected from contact with the underlying silver. If antimicrobials are to be incorporated into catheters to prevent encrustation, it is important that they diffuse into the urine and prevent the rise in pH that triggers crystal formation.
Urinary catheters: history, current status, adverse events and research agenda
Feneley, Roger C. L.; Hopley, Ian B.; Wells, Peter N. T.
2015-01-01
Abstract For more than 3500 years, urinary catheters have been used to drain the bladder when it fails to empty. For people with impaired bladder function and for whom the method is feasible, clean intermittent self-catheterization is the optimal procedure. For those who require an indwelling catheter, whether short- or long-term, the self-retaining Foley catheter is invariably used, as it has been since its introduction nearly 80 years ago, despite the fact that this catheter can cause bacterial colonization, recurrent and chronic infections, bladder stones and septicaemia, damage to the kidneys, the bladder and the urethra, and contribute to the development of antibiotic resistance. In terms of medical, social and economic resources, the burden of urinary retention and incontinence, aggravated by the use of the Foley catheter, is huge. In the UK, the harm resulting from the use of the Foley catheter costs the National Health Service between £1.0–2.5 billion and accounts for ∼2100 deaths per year. Therefore, there is an urgent need for the development of an alternative indwelling catheter system. The research agenda is for the new catheter to be easy and safe to insert, either urethrally or suprapubically, to be retained reliably in the bladder and to be withdrawn easily and safely when necessary, to mimic natural physiology by filling at low pressure and emptying completely without damage to the bladder, and to have control mechanisms appropriate for all users. PMID:26383168
21 CFR 876.5090 - Suprapubic urological catheter and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... accessories is a flexible tubular device that is inserted through the abdominal wall into the urinary bladder with the aid of a trocar and cannula. The device is used to pass fluids to and from the urinary tract...
A new technique of laparoscopic cholangiography.
Hagan, K D; Rosemurgy, A S; Albrink, M H; Carey, L C
1992-04-01
With the advent and rapid proliferation of laparoscopic cholecystectomy, numerous techniques and "tips" have been described. Intraoperative cholangiography during laparoscopic cholecystectomy can be tedious, frustrating, and time consuming. Described herein is a technique of intraoperative cholangiography during laparoscopic cholecystectomy which has proven to be easy, fast, and succinct. This method utilizes a rigid cholangiogram catheter which is placed into the peritoneal cavity through a small additional puncture site. This catheter is easily inserted into the cystic duct by extracorporeal manipulation. We suggest this method to surgeons who have shared our prior frustration with intraoperative cholangiography.
Stenzelius, Karin; Laszlo, Liselott; Madeja, Magdalena; Pessah-Rasmusson, Hélène; Grabe, Magnus
2016-12-01
Catheter-associated urinary tract infection (CAUTI) is the most common healthcare-associated infection. The primary aim of this study was to investigate whether the use of a silicone catheter coated with an ultrathin layer of a combination of the noble metals gold, palladium and silver (BIP™-silicone catheter) could reduce the incidence of CAUTI and antibiotic prescription compared with a standard silicone catheter in a cohort of acute neurological patients suffering primarily from stroke. At the same time, all infectious events requiring prescription of an antimicrobial agent were registered and are reported. The study was designed as a crossover cohort study enrolling men and women aged over 18 years, requiring emergency management for stroke including the insertion of an indwelling catheter. Data on patient characteristics, urinary tract infections (UTIs), other infectious events and all antibiotic prescriptions were recorded prospectively. The patients' characteristics differed in the two centres in terms of age but not in diagnosis distribution. UTIs were recorded in 78 (24.2%) of the patients, ahead of pulmonary tract infections (n = 65; 20.2%). There was no difference in terms of CAUTI in the two catheter groups, even in subgroups with catheter treatment for 1 week or less. The patients with a diagnosed UTI required 3.5 more days of hospitalization than those without a UTI. CAUTIs were the most frequent healthcare-associated infections, slightly ahead of pulmonary tract infections. No advantages of the coated catheter could be found in this cohort of critically ill patients.
[Effect of modified Badenoch operation on the treatment of posterior urethral stricture].
Wang, Ping-xian; Zhang, Gen-pu; Huang, Chi-bing; Fan, Ming-qi; Feng, Jia-yu; Xiao, Ya
2012-02-01
To determine the effects of modified pull-through operation (Badenoch operation) on the treatment of posterior urethral stricture. From September 2001 to December 2010 traditional pull-through operation was Modified for two times in our center. A total of 129 patients with posttraumatic posterior urethral stricture resulting from pelvic fracture injury underwent the modified urethral pull-through operation. Stricture length was 1.5 to 5.3 cm (mean 2.9 cm). Of the patients 43 had undergone at least 1 previous failed management for stricture. In phase 1 (from September 2001 to January 2008), the improving items include: (1) The distal urethral end was stitched and tied to the catheter. (2) As catheter was inserted into bladder and 20 ml water was injected into catheter balloon, the distal urethral end was fixed in the proximal urethra and an overlaying of 1.5 cm was formed between the two ends. (3) Three weeks later, it was tried to insert the catheter to bladder. After the urethral stump necrosis and the catheter separating from the urethra, the catheter was removed. In phase 2 (from February 2008 to December 2010), based on the above, irrigating catheter was used. After the surgery, urethra was irrigated with 0.02% furacillin solution through the catheter 3 times a day. All patients were followed up for at least 6 months. If patients had no conscious dysuria and maximum urinary flow rate (Qmax) > 15 ml/s, the treatment was considered successful. All complications were recorded. In phase 1, the 96 patients (101 times) underwent the procedure. The treatment was successful in 88 patients (success rate 92%). Within 1 to 13 days after removal of the catheter, urethral stricture was recurred in 8 patients. They had to undergo cystostomy once more for 3 to 11 months before reoperation (the 3 patients' reoperation was in phase 2). The 8 cases were treated successfully. In phase 2, 33 patients (total 36 times) underwent the procedure. One patient was failed (success rate 97%). The actual follow-up time is 7 to 93 months (An average of 37.6 months). Qmax is (22 ± 5) ml/s. No complications such as urinary incontinence, erectile pain, urinary shortening happened. The modified urethral pull-through operation is effective for the surgical treatment of posttraumatic posterior urethral stricture. It has a high success rate with durable long-term results. Complications are few. The procedure is simple, less demanding and especially suitable in patients who had previously undergone failed surgical treatments.
Horng, Huann-Cheng; Yuan, Chiou-Chung; Chao, Kuan-Chong; Cheng, Ming-Huei; Wang, Peng-Hui
2007-06-01
To evaluate the efficacy and acceptability of the Port-A-Cath (PAC) insertion method with (conventional group as II) and without (modified group as I) the aid of intraoperative fluoroscopy or other localizing devices. A total of 158 women with various kinds of gynecological cancers warranting PAC insertion (n = 86 in group I and n = 72 in group II, respectively) were evaluated. Data for analyses included patient age, main disease, dislocation site, surgical time, complications, and catheter outcome. There was no statistical difference between the two groups in terms of age, main disease, complications, and the experiencing of patent catheters. However, appropriate positioning (100% in group I, and 82% in group II) in the superior vena cava (SVC) showed statistical differences between the two groups (P = 0.001). In addition, the surgical time in group I was statistically shorter than that in group II (P < 0.001). The modified method for inserting the PAC offered the following benefits: including avoiding X-ray exposure for both the operator and the patient, defining the appropriate position in the SVC, and less surgical time. (c) 2007 Wiley-Liss, Inc.
Timsit, Jean-François; Mimoz, Olivier; Mourvillier, Bruno; Souweine, Bertrand; Garrouste-Orgeas, Maïté; Alfandari, Serge; Plantefeve, Gaétan; Bronchard, Régis; Troche, Gilles; Gauzit, Remy; Antona, Marion; Canet, Emmanuel; Bohe, Julien; Lepape, Alain; Vesin, Aurélien; Arrault, Xavier; Schwebel, Carole; Adrie, Christophe; Zahar, Jean-Ralph; Ruckly, Stéphane; Tournegros, Caroline; Lucet, Jean-Christophe
2012-12-15
Most vascular catheter-related infections (CRIs) occur extraluminally in patients in the intensive care unit (ICU). Chlorhexidine-impregnated and strongly adherent dressings may decrease catheter colonization and CRI rates. To determine if chlorhexidine-impregnated and strongly adherent dressings decrease catheter colonization and CRI rates. In a 2:1:1 assessor-masked randomized trial in patients with vascular catheters inserted for an expected duration of 48 hours or more in 12 French ICUs, we compared chlorhexidine dressings, highly adhesive dressings, and standard dressings from May 2010 to July 2011. Coprimary endpoints were major CRI with or without catheter-related bloodstream infection (CR-BSI) with chlorhexidine versus nonchlorhexidine dressings and catheter colonization rate with highly adhesive nonchlorhexidine versus standard nonchlorhexidine dressings. Catheter-colonization, CR-BSIs, and skin reactions were secondary endpoints. A total of 1,879 patients (4,163 catheters and 34,339 catheter-days) were evaluated. With chlorhexidine dressings, the major-CRI rate was 67% lower (0.7 per 1,000 vs. 2.1 per 1,000 catheter-days; hazard ratio [HR], 0.328; 95% confidence interval [CI], 0.174-0.619; P = 0.0006) and the CR-BSI rate 60% lower (0.5 per 1,000 vs. 1.3 per 1,000 catheter-days; HR, 0.402; 95% CI, 0.186-0.868; P = 0.02) than with nonchlorhexidine dressings; decreases were noted in catheter colonization and skin colonization rates at catheter removal. The contact dermatitis rate was 1.1% with and 0.29% without chlorhexidine. Highly adhesive dressings decreased the detachment rate to 64.3% versus 71.9% (P < 0.0001) and the number of dressings per catheter to two (one to four) versus three (one to five) (P < 0.0001) but increased skin colonization (P < 0.0001) and catheter colonization (HR, 1.650; 95% CI, 1.21-2.26; P = 0.0016) without influencing CRI or CR-BSI rates. A large randomized trial demonstrated that chlorhexidine-gel-impregnated dressings decreased the CRI rate in patients in the ICU with intravascular catheters. Highly adhesive dressings decreased dressing detachment but increased skin and catheter colonization. Clinical trial registered with www.clinicaltrials.gov (NCT 01189682).
Coupez, Elisabeth; Timsit, Jean-François; Ruckly, Stéphane; Schwebel, Carole; Gruson, Didier; Canet, Emmanuel; Klouche, Kada; Argaud, Laurent; Bohe, Julien; Garrouste-Orgeas, Maïté; Mariat, Christophe; Vincent, François; Cayot, Sophie; Cointault, Olivier; Lepape, Alain; Darmon, Michael; Boyer, Alexandre; Azoulay, Elie; Bouadma, Lila; Lautrette, Alexandre; Souweine, Bertrand
2016-07-30
Intensive care unit (ICU) patients require dialysis catheters (DCs) for renal replacement therapy (RRT). They carry a high risk of developing end-stage renal disease, and therefore their vascular access must be preserved. Guidewire exchange (GWE) is often used to avoid venipuncture insertion (VPI) at a new site. However, the impact of GWE on infection and dysfunction of DCs in the ICU is unknown. Our aim was to compare the effect of GWE and VPI on DC colonization and dysfunction in ICU patients. Using data from the ELVIS randomized controlled trial (RCT) (1496 ICU adults requiring DC for RRT or plasma exchange) we performed a matched-cohort analysis. Cases were DCs inserted by GWE (n = 178). They were matched with DCs inserted by VPI. Matching criteria were participating centre, simplified acute physiology score (SAPS) II +/-10, insertion site (jugular or femoral), side for jugular site, and length of ICU stay before DC placement. We used a marginal Cox model to estimate the effect of DC insertion (GWE vs. VPI) on DC colonization and dysfunction. DC colonization rate was not different between GWE-DCs and VPI-DCs (10 (5.6 %) for both groups) but DC dysfunction was more frequent with GWE-DCs (67 (37.6 %) vs. 28 (15.7 %); hazard ratio (HR), 3.67 (2.07-6.49); p < 0.01). Results were similar if analysis was restricted to DCs changed for dysfunction. GWE for DCs in ICU patients, compared with VPI did not contribute to DC colonization or infection but was associated with more than twofold increase in DC dysfunction. This study is registered with ClinicalTrials.gov, number NCT00563342 . Registered 2 April 2009.
Comparing new BSN RN self skills assessment to actual skills demonstration.
Adair, Jean; Hughes, Lin; Davis, Sue; Wolcott-Breci, Mary
2014-01-01
The purpose of the study was to compare the self-skills assessment with the skill competence during an actual skills demonstration of newly hired bachelor of science in nursing (BSN) registered nurse graduates. This retrospective study included 32 randomly selected BSN registered nurse graduates from January 2010 to December 31, 2010. The participants were already hired into a midwest health system. Because this was a retrospective study, no demographic data were collected, and no consent from participants was needed. This study included a clinical skills check list where the participants rated themselves on specific skills utilizing a Likert scale ranging from 1 (no knowledge) to 4 (able to perform independently). The same clinical check list was utilized by an expert registered nurse when the skill was demonstrated. This study compared the difference between the subject's self-rating of skills and the clinical demonstration of the skills. We used t tests in the analysis to demonstrate the differences between the participant's self-rating of skills and the expert evaluation of the clinical demonstration of the skills. The data were inserted into the Statistical Package for the Social Sciences 19 software program to assist in the analysis process. The study demonstrated 17 significant differences in the skills ratings between the participant and competency demonstration of new BSN graduates. These significant results (2 tailed) ranged from .000 to .048.The 17 out of 46 specific skills where differences were noted included the following: staple removal, nasal pharyngeal suctioning, urinary catheter specimen collection, site care dressing change, urinary catheter irrigation, Juzo application and measurement, 5-lead telemetry, oral airway insertion, hemovac/Jackson Pratt, oral pharyngeal suctioning, urinary catheter insertion, dry suction chest drainage, bed to cart/slider board, urinary catheter removal, antiembolism stockings, measurement and application, removal of iv and sit-and-stand alarm. Overall, the participants rated their skill levels lower in 15 out of 17 significant skills when compared with their competency assessment (t test: -3.284, df = 31, P = .003). In two skill ratings (urinary catheter specimen collection and oral pharyngeal suction), the participants rated themselves higher than the competency demonstration. Two skills that had a mean participant and expert score between 1 (no knowledge) and 2 (able to perform with 1-to-1 coaching) were oral airway insertion and dry suction chest drainage. Some possible reasons why the participants rated themselves lower could be the use of different or unfamiliar terms or uncertainty of the procedure at a different health institution. Some newly graduated BSN nurses may have not performed the skills on a regular basis or only in simulation. © 2014.
Schuerer, Douglas J E; Zack, Jeanne E; Thomas, James; Borecki, Ingrid B; Sona, Carrie S; Schallom, Marilyn E; Venker, Melissa; Nemeth, Jennifer L; Ward, Myrna R; Verjan, Linda; Warren, David K; Fraser, Victoria J; Mazuski, John E; Boyle, Walter A; Buchman, Timothy G; Coopersmith, Craig M
2007-08-01
Current guidelines recommend using antiseptic- or antibiotic-impregnated central venous catheters (CVCs) if, following a comprehensive strategy to prevent catheter-related blood stream infection (CR-BSI), infection rates remain above institutional goals based on benchmark values. The purpose of this study was to determine if chlorhexidine/silver sulfadiazine-impregnated CVCs could decrease the CR-BSI rate in an intensive care unit (ICU) with a low baseline infection rate. Pre-intervention and post-intervention observational study in a 24-bed surgical/trauma/burn ICU from October, 2002 to August, 2005. All patients requiring CVC placement after March, 2004 had a chlorhexidine/silver sulfadiazine-impregnated catheter inserted (post-intervention period). Twenty-three CR-BSIs occurred in 6,960 catheter days (3.3 per 1,000 catheter days)during the 17-month control period. After introduction of chlorhexidine/silver sulfadiazine-impregnated catheters, 16 CR-BSIs occurred in 7,732 catheter days (2.1 per 1,000 catheter days; p = 0.16). The average length of time required for an infection to become established after catheterization was similar in the two groups (8.4 vs. 8.6 days; p = 0.85). Chlorhexidine/silver sulfadiazine-impregnated catheters did not result in a statistically significant change in the microbiological profile of CR-BSIs, nor did they increase the incidence of resistant organisms. Although chlorhexidine/silver sulfadiazine-impregnated catheters are useful in specific patient populations, they did not result in a statistically significant decrease in the CR-BSI rate in this study, beyond what was achieved with education alone.
A linear stepping endovascular intervention robot with variable stiffness and force sensing.
He, Chengbin; Wang, Shuxin; Zuo, Siyang
2018-05-01
Robotic-assisted endovascular intervention surgery has attracted significant attention and interest in recent years. However, limited designs have focused on the variable stiffness mechanism of the catheter shaft. Flexible catheter needs to be partially switched to a rigid state that can hold its shape against external force to achieve a stable and effective insertion procedure. Furthermore, driving catheter in a similar way with manual procedures has the potential to make full use of the extensive experience from conventional catheter navigation. Besides driving method, force sensing is another significant factor for endovascular intervention. This paper presents a variable stiffness catheterization system that can provide stable and accurate endovascular intervention procedure with a linear stepping mechanism that has a similar operation mode to the conventional catheter navigation. A specially designed shape-memory polymer tube with water cooling structure is used to achieve variable stiffness of the catheter. Hence, four FBG sensors are attached to the catheter tip in order to monitor the tip contact force situation with temperature compensation. Experimental results show that the actuation unit is able to deliver linear and rotational motions. We have shown the feasibility of FBG force sensing to reduce the effect of temperature and detect the tip contact force. The designed catheter can change its stiffness partially, and the stiffness of the catheter can be remarkably increased in rigid state. Hence, in the rigid state, the catheter can hold its shape against a [Formula: see text] load. The prototype has also been validated with a vascular phantom, demonstrating the potential clinical value of the system. The proposed system provides important insights into the design of compact robotic-assisted catheter incorporating effective variable stiffness mechanism and real-time force sensing for intraoperative endovascular intervention.
Clark, Edward G; Paparello, James J; Wayne, Diane B; Edwards, Cedric; Hoar, Stephanie; McQuillan, Rory; Schachter, Michael E; Barsuk, Jeffrey H
2014-01-01
Simulation-based-mastery-learning (SBML) is an effective method to train nephrology fellows to competently insert temporary, non-tunneled hemodialysis catheters (NTHCs). Previous studies of SBML for NTHC-insertion have been conducted at a local level. Determine if SBML for NTHC-insertion can be effective when provided at a national continuing medical education (CME) meeting. Describe the correlation of demographic factors, prior experience with NTHC-insertion and procedural self-confidence with simulated performance of the procedure. Pre-test - post-test study. 2014 Canadian Society of Nephrology annual meeting. Nephrology fellows, internal medicine residents and medical students. Participants were surveyed regarding demographics, prior NTHC-insertion experience, procedural self-confidence and attitudes regarding the training they received. NTHC-insertion skills were assessed using a 28-item checklist. Participants underwent a pre-test of their NTHC-insertion skills at the internal jugular site using a realistic patient simulator and ultrasound machine. Participants then had a training session that included a didactic presentation and 2 hours of deliberate practice using the simulator. On the following day, trainees completed a post-test of their NTHC-insertion skills. All participants were required to meet or exceed a minimum passing score (MPS) previously set at 79%. Trainees who did not reach the MPS were required to perform more deliberate practice until the MPS was achieved. Twenty-two individuals participated in SBML training. None met or exceeded the MPS at baseline with a median checklist score of 20 (IQR, 7.25 to 21). Seventeen of 22 participants (77%) completed post-testing and improved their scores to a median of 27 (IQR, 26 to 28; p < 0.001). All met or exceeded the MPS on their first attempt. There were no significant correlations between demographics, prior experience or procedural self-confidence with pre-test performance. Small sample-size and self-selection of participants. Costs could limit the long-term feasibility of providing this type of training at a CME conference. Despite most participants reporting having previously inserted NTHCs in clinical practice, none met the MPS at baseline; this suggests their prior training may have been inadequate.
Nowak, Zbigniew; Laudanski, Krzysztof
2016-01-01
Background Conformity is a psychological variable related to the propensity of an individual to match his or her behavior and opinion to the perceived social and cultural norm, even if these do not represent the true beliefs of the person. The aim of the present study was to investigate whether the psychological variable of conformity is different in two distinct modes of renal replacement therapy (RRT) in end-stage renal disease (ESRD). Material/Methods A total of 56 hemodialyzed patients (HD group), 45 continuous ambulatory peritoneal dialysis patients (CAPD group) and 62 healthy volunteers (CONTR group) were enrolled in the study. The Social Appraisal Questionnaire (SAQ) was employed, and chart review was performed to collect clinical data. Results When age was not a factor, the conformity measure was significantly higher in the HD group compared with the CAPD and CONTR groups. The lowest conformity was found in healthy participants who were asked to imagine an acute medical problem. The highest conformity was found in older HD and CAPD patients. Conclusions Being chronically ill and having adaptable views may be more favorable traits for coping with ESRD in dialyzed patients, especially in elderly HD patients. On the other hand, conformity can be deleterious if CAPD patients decide to overlook certain facts or not confront the medical aspects of their condition. PMID:27886156
Shalit, I; Greenwood, R B; Marks, M I; Pederson, J A; Frederick, D L
1986-01-01
The prevention and treatment of peritonitis in patients undergoing peritoneal dialysis is often complicated by several factors, including nephrotoxicity, requirement for hospitalization, parenteral antibiotic therapy, and infection caused by resistant microorganisms. Ciprofloxacin, a new carboxyquinolone derivative, may offer the advantages of oral administration, a broad spectrum of antibacterial activity, and safety for the management of these patients. The pharmacokinetics of ciprofloxacin in serum and peritoneal fluid of eight adult patients undergoing chronic ambulatory peritoneal dialysis (CAPD) were investigated. Each patient ingested a single 750-mg dose of ciprofloxacin, and drug concentrations were measured by high-pressure liquid chromatography in serum and peritoneal fluid for 48 h after the dose. Serum concentrations reached a mean peak of 3.6 micrograms/ml 1 to 2 h after the oral dose. The mean terminal serum half-life was 16.8 h, and the mean peritoneal fluid/serum concentration ratio was 0.64. The mean peak ciprofloxacin concentration in peritoneal fluid was 1.3 micrograms/ml, and the bioactivity of the drug in peritoneal fluid was confirmed. These data indicated that therapeutic concentrations of ciprofloxacin against bacterial pathogens commonly associated with peritonitis in CAPD patients may be achievable in the peritoneal fluid after oral administration to patients undergoing CAPD. In addition, the pharmacokinetic data provide guidelines for further clinical studies of oral ciprofloxacin in CAPD patients. PMID:2944477
Maeda, Ryoko; Kohno, Yumiko; Hoshino, Hajime; Suzuki, Hideo; Hirabayashi, Yoshiyuki; Seo, Norimasa
2003-08-01
A 48-year-old woman with aortitis syndrome underwent clipping of dissecting aneurysm of the left posterior inferior cerebellar artery following subarachnoid hemorrhage. Preoperative echocardiography demonstrated moderate aortic regurgitation and pulmonary hypertension. Intravenous infusion (1900 ml.day-1) was performed to avoid cerebral vasospasm, but the patient developed lung edema. She received delayed surgical treatment after the improvement of lung symptoms. Anesthesia was induced with fentanyl (0.1 mg), propofol (90 mg) and vecuronium (6 mg). Radial arterial flow was judged to be insufficient for cannulation, and a cannulation was therefore performed on the dorsal pedis artery. During induction of anesthesia, there was a significant decrease in the arterial pressure, that required a total of 32 mg of intravenous ephedrine. Following tracheal intubation, a central venous catheter was inserted and dopamine was continuously administered. The patient was positioned in the park bench position. We thought that the placement of the introducer for Swan-Ganz catheter was difficult under the position and Swan-Ganz catheter was not inserted. Anesthesia was maintained with sevoflurane, air, and oxygen. We continuously monitored the central venous pressure as an indicator of fluid balance. In this case, we monitored dorsal pedis arterial pressure directly, which might not be sufficiently reliable to predict the decrease in cerebral blood flow.
Uslusoy, Esin; Mete, Samiye
2008-04-01
The purpose of this study was to investigate the predisposing factors in the development of phlebitis in peripheral intravenous (IV) catheterization sites in patients treated with a variety of IV infusion solutions and drugs. Systematic observation of 568 IV sites inserted for fluid infusion and drug administration in 355 patients in the Department of General Surgery of a University Hospital in Turkey. A data collection tool was based on standards established by the Infusion Nurses Society. Patients' infusion sites were monitored every 24 h during treatment and for 48 h after discontinuation of the IV. In contrast to the usual findings in the literature, the authors found that infusion through an infusion pump and insertion of catheters in the veins around the elbow increased the risk of phlebitis. Also, the number of times infusions were started led to an increased rate of phlebitis. However, conflicting results were obtained about the relation between phlebitis, gender, and catheter size. Phlebitis causes sepsis, pain, additional diagnostic investigations, and treatments, and may lead to increased duration of hospitalization, patient's stress level, and financial burden, as well as increasing staff workload. Advanced practice nurses need to be aware of the factors that increase the likelihood of phlebitis and take appropriate measures to prevent it.
Vaidyanathan, Subramanian; Soni, Bakul; Singh, Gurpreet; Hughes, Peter; Oo, Tun
2011-01-01
When urethral catheterisation is difficult or impossible in spinal cord injury patients, flexible cystoscopy and urethral catheterisation over a guide wire can be performed on the bedside, thus obviating the need for emergency suprapubic cystostomy. Spinal cord injury patients, who undergo flexible cystoscopy and urethral catheterisation over a guide wire, may develop potentially serious complications. (1) Persons with lesion above T-6 are susceptible to develop autonomic dysreflexia during cystoscopy and urethral catheterisation over a guide wire; nifedipine 5-10 milligrams may be administered sublingually just prior to the procedure to prevent autonomic dysreflexia. (2) Spinal cord injury patients are at increased risk for getting urine infections as compared to able-bodied individuals. Therefore, antibiotics should be given to patients who get haematuria or urethral bleeding following urethral catheterisation over a guide wire. (3) Some spinal cord injury patients may have a small capacity bladder; in these patients, the guide wire, which is introduced into the urinary bladder, may fold upon itself with the tip of guide wire entering the urethra. If this complication is not recognised and a catheter is inserted over the guide wire, the Foley catheter will then be misplaced in urethra despite using cystoscopy and guide wire.
Vaidyanathan, Subramanian; Soni, Bakul; Singh, Gurpreet; Hughes, Peter; Oo, Tun
2011-01-01
When urethral catheterisation is difficult or impossible in spinal cord injury patients, flexible cystoscopy and urethral catheterisation over a guide wire can be performed on the bedside, thus obviating the need for emergency suprapubic cystostomy. Spinal cord injury patients, who undergo flexible cystoscopy and urethral catheterisation over a guide wire, may develop potentially serious complications. (1) Persons with lesion above T-6 are susceptible to develop autonomic dysreflexia during cystoscopy and urethral catheterisation over a guide wire; nifedipine 5–10 milligrams may be administered sublingually just prior to the procedure to prevent autonomic dysreflexia. (2) Spinal cord injury patients are at increased risk for getting urine infections as compared to able-bodied individuals. Therefore, antibiotics should be given to patients who get haematuria or urethral bleeding following urethral catheterisation over a guide wire. (3) Some spinal cord injury patients may have a small capacity bladder; in these patients, the guide wire, which is introduced into the urinary bladder, may fold upon itself with the tip of guide wire entering the urethra. If this complication is not recognised and a catheter is inserted over the guide wire, the Foley catheter will then be misplaced in urethra despite using cystoscopy and guide wire. PMID:22110492
DOE Office of Scientific and Technical Information (OSTI.GOV)
Damato, AL; Bhagwat, MS; Buzurovic, I
Purpose: To investigate the use of a system using EM tracking, postprocessing and error-detection algorithms for measuring brachytherapy catheter locations and for detecting errors and resolving uncertainties in treatment-planning catheter digitization. Methods: An EM tracker was used to localize 13 catheters in a clinical surface applicator (A) and 15 catheters inserted into a phantom (B). Two pairs of catheters in (B) crossed paths at a distance <2 mm, producing an undistinguishable catheter artifact in that location. EM data was post-processed for noise reduction and reformatted to provide the dwell location configuration. CT-based digitization was automatically extracted from the brachytherapy planmore » DICOM files (CT). EM dwell digitization error was characterized in terms of the average and maximum distance between corresponding EM and CT dwells per catheter. The error detection rate (detected errors / all errors) was calculated for 3 types of errors: swap of two catheter numbers; incorrect catheter number identification superior to the closest position between two catheters (mix); and catheter-tip shift. Results: The averages ± 1 standard deviation of the average and maximum registration error per catheter were 1.9±0.7 mm and 3.0±1.1 mm for (A) and 1.6±0.6 mm and 2.7±0.8 mm for (B). The error detection rate was 100% (A and B) for swap errors, mix errors, and shift >4.5 mm (A) and >5.5 mm (B); errors were detected for shifts on average >2.0 mm (A) and >2.4 mm (B). Both mix errors associated with undistinguishable catheter artifacts were detected and at least one of the involved catheters was identified. Conclusion: We demonstrated the use of an EM tracking system for localization of brachytherapy catheters, detection of digitization errors and resolution of undistinguishable catheter artifacts. Automatic digitization may be possible with a registration between the imaging and the EM frame of reference. Research funded by the Kaye Family Award 2012.« less
Extravasation Injuries in Adults
Al-Benna, S.; O'Boyle, C.; Holley, J.
2013-01-01
Insertion of an intravascular catheter is one of the most common invasive procedures in hospitals worldwide. These intravascular lines are crucial in resuscitation, allow vital medication to be administered, and can be used to monitor the patients' real-time vital parameters. There is, however, growing recognition of potential risks to life and limb associated with their use. Medical literature is now replete with isolated case reports of complications succinctly described by Garden and Laussen (2004) as “An unending supply of “unusual” complications from central venous catheters.” This paper reviews complications of venous and arterial catheters and discusses treatment approaches and methods to prevent complications, based on current evidence and endeavours to provide information and guidance that will enable practitioners to prevent, recognise, and successfully treat extravasation injuries in adults. PMID:23738141
Kitazawa, T; Ishigaki, S; Seo, K; Yoshino, Y; Ota, Y
2018-06-01
Rhodotorula species are environmental basidiomycete yeasts that have emerged as a cause of fungemia in immunocompromised hosts. The insertion of a central venous catheter was identified as a major risk factor for Rhodotorula fungemia. Few cases reports have reported (1→3)-β-D-glucan testing at the onset of Rhodotorula mucilaginosa fungemia. We report a case of catheter-related bloodstream infection due to R. mucilaginosa. Serum β-D-glucan level was normal at the onset of the bloodstream infection. It took 5 days to culture the isolate. The patient's fever persisted after empiric treatment with micafungin, and a switch to oral voriconazole immediately resolved the fungemia. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Central venous catheters: incidence and predictive factors of venous thrombosis.
Hammes, Mary; Desai, Amishi; Pasupneti, Shravani; Kress, John; Funaki, Brian; Watson, Sydeaka; Herlitz, Jean; Hines, Jane
2015-07-01
Central venous catheter access in an acute setting can be a challenge given underlying disease and risk for venous thrombosis. Peripherally inserted central venous catheters (PICCs) are commonly placed but limit sites for fistula creation in patients with chronic renal failure (CKD). The aim of this study is to determine the incidence of venous thrombosis from small bore internal jugular (SBIJ) and PICC line placement. This investigation identifies populations of patients who may not be ideal candidates for a PICC and highlights the importance of peripheral vein preservation in patients with renal failure. A venous Doppler ultrasound was performed at the time of SBIJ insertion and removal to evaluate for thrombosis in the internal jugular vein. Data was collected pre- and post-intervention to ascertain if increased vein preservation knowledge amongst the healthcare team led to less use of PICCs. Demographic factors were collected in the SBIJ and PICC groups and risk factor analysis was completed. 1,122 subjects had PICC placement and 23 had SBIJ placement. The incidence of thrombosis in the PICC group was 10%. One patient with an SBIJ had evidence of central vein thrombosis when the catheter was removed. Univariate and multivariate analysis demonstrated a history of transplant, and the indication of total parenteral nutrition was associated with thrombosis (p<0.001). The decrease in PICCs placed in patients with CKD 6 months before and after intervention was significant (p<0.05). There are subsets of patients ith high risk for thrombosis who may not be ideal candidates for a PICC.
Pikwer, Andreas; Acosta, Stefan; Kölbel, Tilo; Åkeson, Jonas
2010-01-01
This study was designed to assess endovascular intervention for central venous cannulation in patients with vascular occlusion after previous catheterization. Patients referred for endovascular management of central venous occlusion during a 42-month period were identified from a regional endovascular database, providing prospective information on techniques and clinical outcome. Corresponding patient records, angiograms, and radiographic reports were analyzed retrospectively. Sixteen patients aged 48 years (range 0.5-76), including 11 females, were included. All patients but 1 had had multiple central venous catheters with a median total indwelling time of 37 months. Eleven patients cannulated for hemodialysis had had significantly fewer individual catheters inserted compared with 5 patients cannulated for nutritional support (mean 3.6 vs. 10.2, p<0.001) before endovascular intervention. Preoperative imaging by magnetic resonance tomography (MRT) in 8 patients, computed tomography (CT) venography in 3, conventional angiography in 6, and/or ultrasonography in 8, verified 15 brachiocephalic, 13 internal jugular, 3 superior caval, and/or 3 subclavian venous occlusions. Patients were subjected to recanalization (n=2), recanalization and percutaneous transluminal angioplasty (n=5), or stenting for vena cava superior syndrome (n=1) prior to catheter insertion. The remaining 8 patients were cannulated by avoiding the occluded route. Central venous occlusion occurs particularly in patients under hemodialysis and with a history of multiple central venous catheterizations with large-diameter catheters and/or long total indwelling time periods. Patients with central venous occlusion verified by CT or MRT venography and need for central venous access should be referred for endovascular intervention.
Practices related to late-onset sepsis in very low-birth weight preterm infants.
Bentlin, Maria Regina; Rugolo, Ligia M S S; Ferrari, Ligia S L
2015-01-01
To understand the practices related to late-onset sepsis (LOS) in the centers of the Brazilian Neonatal Research Network, and to propose strategies to reduce the incidence of LOS. This was a cross-sectional descriptive multicenter study approved by the Ethics Committee. Three questionnaires regarding hand hygiene, vascular catheters, and diagnosis/treatment of LOS were sent to the coordinator of each center. The center with the lowest incidence of LOS was compared with the others. All 16 centers answered the questionnaires. Regarding hand hygiene, 87% use chlorhexidine or 70% alcohol; alcohol gel is used in 100%; 80% use bedside dispensers (50% had one dispenser for every two beds); practical training occurs in 100% and theoretical training in 70% of the centers, and 37% train once a year. Catheters: 94% have a protocol, and 75% have a line insertion team. Diagnosis/treatment: complete blood count and blood culture are used in 100%, PCR in 87%, hematological scores in 75%; oxacillin and aminoglycosides is the empirical therapy in 50% of centers. Characteristics of the center with lowest incidence of LOS: stricter hand hygiene; catheter insertion and maintenance groups; use of blood culture, PCR, and hematological score for diagnosis; empirical therapy with oxacillin and aminoglycoside. The knowledge of the practices of each center allowed for the identification of aspects to be improved as a strategy to reduce LOS, including: alcohol gel use, hand hygiene training, implementation of catheter teams, and wise use of antibiotic therapy. Copyright © 2013 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.
Chow, Vincent C; Yong, Rose M; Li, Alice L; Lee, Chi-wai; Ho, Eva H; Chan, Ching-kit; Lo, Stanley H; Mo, Stephen K; Wong, Kin-shing
2003-12-01
Nutritional status is related to morbidity and mortality in the continuous ambulatory peritoneal dialysis (CAPD) population. In the present study, we compared the dietary intake of CAPD patients with their requirements for calorie and protein nutrition and with the recommended intakes of potassium and phosphate. Patients were recruited from the CAPD clinic. Desirable body weight was derived from the height of the individual patients and the desirable body mass index (BMI) for adult Asians. The calorie requirement was calculated by multiplying desirable body weight by 30 kcal. The protein requirement was calculated by multiplying desirable body weight by 1.2 - 1.5, according to serum albumin level. The K requirement was set at 3500 mg daily, and the PO(4) requirement, at 1000 mg daily. The actual dietary intake of individual patients was estimated from dietary history by a computer software program. The study included 57 patients who had been on CAPD for 22.1 +/- 23.5 months. Of the 57 patients, 8 patients (14.0%) were below the desirable BMI range, 20 (35.1%) were within the range, and 29 (50.9%) were above the range. By subjective global assessment (SGA), 45 patients (78.9%) were mildly-to-moderately malnourished, and 12 (21.1%) well nourished. Serum albumin was 32.1 +/- 4.7 g/L. Patients met 98% +/- 35.7% (range: 33% - 224%) of their nutritional requirement for calories and 92.1% +/- 37.7% (range: 22% - 202%) of their nutritional requirement for protein. Only 23 patients (40.4%) reached the target for calorie intake, and only 22 (38.6%) reached the target for protein intake. Excess K intake was seen in 1 patient (1.8%), and excess PO(4) intake, in 6 patients (10.5%). Actual dietary intake was not related to BMI or SGA score. Most CAPD patients had inadequate calorie and protein intakes. Calorie and protein intakes were not related to BMI and SGA scores. Compliance with recommended K and PO(4) intakes was good.
Jin, Sanli; Lu, Qian; Su, Chunyan; Pang, Dong; Wang, Tao
♦ BACKGROUND: Limited data are available on clinical outcomes among peritoneal dialysis patients with shortage of appendicular skeletal muscle (ASM). In this study, we tested the hypothesis that the shortage of ASM is an independent risk factor for mortality in continuous ambulatory peritoneal dialysis (CAPD) patients. ♦ METHODS: Adult patients undergoing CAPD between March and August 2007 in a single center in China were recruited in this prospective cohort study. Body composition, protein/energy intake, clinical, and biochemical data were collected at baseline, 6 months, and 12 months. End points were all-cause mortality by 12 September 2014. The mean follow-up time was 60.21 (± 24.45) months (11.00 - 89.00). ♦ RESULTS: Compared with the baseline, the mean value of ASM in CAPD patients decreased at 12 months (19.40 ± 5.60 vs 21.85 ± 6.14, p < 0.001). According to the estimation of patient survival by Kaplan-Meier, patients with a shortage of ASM had a worse survival rate than those with normal ASM (χ 2 = 16.588, p < 0.001). In the Cox's proportional hazards model, patients' survival was independently associated with a shortage of ASM (hazard ratio [HR] = 2.318, p = 0.024, 95% confidence interval [CI] = 1.116 - 4.812). Standard daily protein intake (stDPI) and standard daily energy intake (stDEI) in patients with a shortage of ASM were significantly lower than those in patients with normal ASM in the first follow-up year (t = 2.067, p = 0.041; t = 3.673, p = 0.001). ♦ CONCLUSIONS: A shortage of ASM is an independent risk factor for mortality in CAPD patients. Further studies are needed to demonstrate that nutritional intervention helps with improving muscle mass and, consequently, the survival of CAPD patients. Copyright © 2017 International Society for Peritoneal Dialysis.
Risk factor analysis for long-term tunneled dialysis catheter-related bacteremias.
Jean, G; Charra, B; Chazot, C; Vanel, T; Terrat, J C; Hurot, J M; Laurent, G
2002-07-01
Infection, mainly related to vascular access, is one of the main causes of morbidity and a preventable cause of death in hemodialysis patients. From January 1994 to April 1998 we conducted a prospective study to assess the incidence and risk factors of catheter-related bacteremia. One hundred and twenty-nine tunneled dual-lumen hemodialysis catheters were inserted percutaneously into the internal jugular vein in 89 patients. Bacteremia (n = 56) occurred at least once with 37 (29%) of the catheters (an incidence of 1.1/1,000 catheter-days); local infection (n = 45, 1/1,000 catheter-days) was associated with bacteremia in 18 cases. Death in 1 case was directly related to Staphylococcus aureus (SA) septic shock, and septicemia contributed to deaths in 2 additional cases. Catheters were removed in 48% of the bacteremic episodes. Treatment comprised intravenous double antimicrobial therapy for 15-20 days. Bacteriological data of bacteremia showed 55% involvement of SA. Nasal carriage of SA was observed in 35% of the patients with catheters. Bacteremic catheters were more frequently observed in patients with diabetes mellitus (p = 0.03), peripheral atherosclerosis (p = 0.001), a previous history of bacteremia (p = 0.05), nasal carriage of SA (p = 0.0001), longer catheter survival time (p = 0.001), higher total intravenous iron dose (p = 0.001), more frequent urokinase catheter infusion (p < 0.01), and local infection (p < 0.001) compared with non-bacteremic catheters. Monovariate survival analysis showed that significant initial risk factors for bacteremia were nasal carriage of SA (p = 0.00001), previous bacteremia (p = 0.0001), peripheral atherosclerosis (p = 0.005), and diabetes (p = 0.04). This study confirms the relatively high incidence of bacteremia with tunneled double-lumen silicone catheters and its potential complications. Possible preventive actions are discussed according to the risk factors. Copyright 2002 S. Karger AG, Basel
Cicolini, Giancarlo; Manzoli, Lamberto; Simonetti, Valentina; Flacco, Maria Elena; Comparcini, Dania; Capasso, Lorenzo; Di Baldassarre, Angela; Eltaji Elfarouki, Ghaleb
2014-11-01
This multi-centre prospective field study evaluated whether peripheral venous catheter site of insertion influences the risk of catheter-related phlebitis. Potential predictors of phlebitis were also investigated. Millions of patients worldwide use peripheral venous catheters, which frequently cause local complications including phlebitis, infection and obstruction. Although phlebitis predictors have been broadly investigated, uncertainties remain on the potential effect of cannulation anatomical site, duration and the appropriate time for catheter removal. A prospective cohort design was carried out from January-June 2012. The clinical course of each patient who received a new peripheral venous catheter for any cause in five Italian hospitals was followed by trained nurses until catheter removal. The presence of phlebitis was assessed every 24 hours using the Visual Infusion Phlebitis score. Analyses were based upon multilevel mixed-effects regression. The final sample consisted of 1498 patients. The average time for catheters in situ was 65·6 hours and 23·6% of the catheters were in place beyond 96 hours. Overall phlebitis incidence was 15·4%, 94·4% of which were grade 1. The likelihood of phlebitis independently increased with increasing catheter duration, being highest after 96 hours. Compared with patients with catheter placed in the dorsum of the hand (22·8% of the sample), those with the catheter located in the antecubital fossa (34·1%) or forearm were less likely to have a phlebitis of any grade. Antecubital fossa and forearm veins may be preferential sites for peripheral venous cannulation. Our results support Centers for Disease Control and Prevention recommendations to replace catheters in adults no later than 96 hours. A relevant proportion of healthcare personnel did not adhere to such guidelines - more attention to this issue is required. © 2014 John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Keeling, A. N.; Leong, S.; Logan, P. M.
Empyema and complicated pleural effusion represent common medical problems. Current treatment options are multiple. The purpose of this study was to access the outcome of image-guided, small-bore catheter drainage of empyema and effusion. We evaluated 93 small-bore catheters in 82 patients with pleural effusion (n = 30) or empyema (n = 52), over a 2-year period. Image guidance was with ultrasound (US; n = 56) and CT (n = 37). All patients were followed clinically, with catheter dwell times, catheter outcome, pleural fluid outcome, reinsertion rates, and need for urokinase or surgery recorded. Ninety-three small-bore chest drains (mean=10.2 Fr; range,more » 8.2-12.2 Fr) were inserted, with an average dwell time of 7.81 days for empyemas and 7.14 days for effusions (p > 0.05). Elective removal rates (73% empyema vs 86% effusions) and dislodgement rates (12% empyema vs 13% effusions) were similar for both groups. Eight percent of catheters became blocked and 17% necessitated reinsertion in empyemas, with no catheters blocked or requiring reinsertion in effusions (p < 0.05). Thirty-two patients (51%) required urokinase in the empyema group, versus 2 patients (6%) in the effusion group (p < 0.05). All treatment failures, requiring surgery, occurred in the empyema group (19%; n = 12; p < 0.05). In conclusion, noninfected pleural collections are adequately treated with small-bore catheters, however, empyemas have a failure rate of 19%. The threshold for using urokinase and larger-bore catheters should be low in empyema.« less
Fichtner, Jens; Beck, Jürgen; Raabe, A; Stieglitz, Lennart Henning
2015-09-01
For chronic subdural hematoma, placement of a Blake drain with a two-burr-hole craniotomy is often preferred. However, the placement of such drains carries the risk of penetrating the brain surface or damaging superficial venous structures. To describe the use of a Nelaton catheter for the placement of a subdural drain in two-burr-hole trephination for chronic subdural hematoma. A Nelaton catheter was used to guide placement of a Blake drain into the subdural hematoma cavity and provide irrigation of the hematoma cavity. With the two-burr-hole method, the Nelaton catheter could be removed easily via the frontal burr hole after the Blake drain was in place. We used the Nelaton catheters in many surgical procedures and found it a safe and easy technique. This method allows the surgeon to safely direct the catheter into the correct position in the subdural space. This tool has two advantages. First, the use of a small and flexible Nelaton catheter is a safe method for irrigation of a chronic subdural hematoma cavity. Second, in comparison with insertion of subdural drainage alone through a burr hole, the placement of the Nelaton catheter in subdural space is easier and the risk of damaging relevant structures such as cortical tissue or bridging veins is lower. Thus this technique may help to avoid complications when placing a subdural drain. Georg Thieme Verlag KG Stuttgart · New York.
Central venous catheterization for parenteral nutrition.
Padberg, F T; Ruggiero, J; Blackburn, G L; Bistrian, B R
1981-01-01
To define the risks associated with central venous catheterization for total parenteral nutrition (TPN) 3291 patient days of this therapy, delivered by an established nutrition support team, were evaluated. One hundred and seventy-five catheters placed in 104 patients were reviewed over an 18 month period. Positive cultures were reported on 11 cannulae for a 6.4% incidence of colonization; five catheters (2.8%) were considered septic. Pleural or mediastinal complications of subclavian or internal jugular venipuncture occurred in eight patients (4.8%). Misdirection of the catheter tip occurred in 11.5% of insertions. Five patients (4.8%) had clinically apparent thrombosis in the superior vena cava, innominate and/or subclavian veins during hospitalization; four others had evidence of thrombosis at autopsy examination, giving an incidence of 8.7% in the entire series. No death directly resulted from the use of this therapy. Compliance with a rigid protocol by an experienced team can allow safe and effective use of central venous catheters and parenteral nutrition therapy. PMID:6782956
[Femoral arteriovenous fistula: a late uncommon complication of central venous catheterization].
Conz, P A; Malagoli, A; Normanno, M; Munaro, D
2007-01-01
A 77-year-old woman was admitted due to AV graft thrombosis; given the technical impossibility of performing other native AV fistulas, we chose to insert a tunnelled central venous catheter. Considering the vascular history of the patient, the central venous catheter could not be placed into the internal jugular vein; it was therefore put into the left femoral vein. Following a 3-month-period of the catheter working properly, the patient was hospitalized due to sudden acute pain in the left thigh. In a few days the patient developed an important haematoma with serious anemization in the left lower limb. Ultrasonography showed the presence of a fistula between the left common femoral artery and the femoral vein, leading to the subsequent successful positioning of a stent into the common femoral artery through right trans-femoral access. Angiography examination showed the femoral vein patency along the proximal stretch with respect to the function of the tunnelled venous catheter.
Bonzel, T; Wollschläger, H; Kasper, W; Meinertz, T; Just, H
1987-01-01
The sliding rail technique is a new technique for intravascular instrumentation, especially coronary stenosis dilatation. The so-called monorail balloon catheter is the first device which can be used according to this technique. The monorail catheter has a single lumen shaft and only a short central tube within the distal balloon part. With the guidewire inserted into the tube, the balloon can be advanced or retracted on the guidewire as on a sliding rail. The most relevant improvements for coronary dilatation are steerability, contrast flow and rapid and easy exchangeability of balloon catheters and other intracoronary devices. These characteristics are felt to result in a more simple and time- and fluoroscopy-saving dilatation procedure. A special transfusion catheter may also improve procedural safety. The first clinical results in 69 patients with a success rate of 96%, an emergency bypass rate of two patients (one infarction) and a stenosis improvement of 58% confirm the theoretically conceived advantages.
Rebahi, H; El Adib, A G; Mouaffak, Y; El Hattaoui, M; Chaara, A; Sadek, H; Khouchani, M; Mahmal, L; Younous, S
2015-01-01
Totally implantable venous access port plays a crucial role in the treatment of patients in oncology. However, its use can result sporadically in catheter fracture with catheter tip embolization into pulmonary arteries. We report this unusual but potentially serious complication in four patients. In these patients, the port had been inserted percutaneously into the subclavian vein using the infra-clavicular approach. This side effect occurred late in three patients. In all patients, the catheter fracture was asymptomatic or pauci-symptomatic and was caused by the pinch-off syndrome. The retrieval of the embolized fragments was successfully performed by transcatheter procedure in the cardiac catheterisation laboratory. We reviewed the literature and the newest guidelines and recommendations to detail the clinico-radiological features, the possible causes of this complication and discussed means to recognize, manage and prevent it. Copyright © 2013 Société nationale française de médecine interne (SNFMI). Published by Elsevier SAS. All rights reserved.
Accuracy of chest radiography for positioning of the umbilical venous catheter.
Guimarães, Adriana F M; Souza, Aline A C G de; Bouzada, Maria Cândida F; Meira, Zilda M A
To evaluate the accuracy of the simultaneous analysis of three radiographic anatomical landmarks - diaphragm, cardiac silhouette, and vertebral bodies - in determining the position of the umbilical venous catheter distal end using echocardiography as a reference standard. This was a cross-sectional, observational study, with the prospective inclusion of data from all neonates born in a public reference hospital, between April 2012 and September 2013, submitted to umbilical venous catheter insertion as part of their medical care. The position of the catheter distal end, determined by the simultaneous analysis of three radiographic anatomical landmarks, was compared with the anatomical position obtained by echocardiography; sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were calculated. Of the 162 newborns assessed by echocardiography, only 44 (27.16%) had the catheter in optimal position, in the thoracic portion of the inferior vena cava or at the junction of the inferior vena cava with the right atrium. The catheters were located in the left atrium and interatrial septum in 54 (33.33%) newborns, in the right atrium in 26 (16.05%), intra-hepatic in 37 (22.84%), and intra-aortic in-one newborn (0.62%). The sensitivity, specificity and accuracy of the radiography to detect the catheter in the target area were 56%, 71%, and 67.28%, respectively. Anteroposterior radiography of the chest alone is not able to safely define the umbilical venous catheter position. Echocardiography allows direct visualization of the catheter tip in relation to vascular structures and, whenever possible, should be considered to identify the location of the umbilical venous catheter. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.
Aboelela, Mohamed Adel; Kandeel, Al-Refaey; Elsayed, Usama; Elmorshedi, Mohamed; Elsarraf, Waleed; Elsayed, Eman; Elgawalby, Ahmed; Sultan, Ahmed Mohamed; Wahab, Mohamed Abdel; Yassen, Amr
2018-01-01
Transversus abdominis plane (TAP) block is a promising technique for analgesia after abdominal surgery. This prospective, randomized controlled trial assessed the effect of adding dexmedetomidine to bupivacaine in TAP block for donor hepatectomy. We hypothesized that this would improve postoperative morphine consumption and reduce analgesia related complication and inflammation. A total of 50 donor hepatectomy were enrolled in this study. Patients divided into two equal groups according to drugs used for TAP block. Group (B) received 20 ml of bupivacaine hydrochloride 0.25%, Group (BD) received 20 ml of bupivacaine hydrochloride 0.25% and 0.3 μg/kg dexmedetomidine, on both sides at the end of surgery and every 8 h for 48 h at right side only through inserted catheter. Primary outcome objective was morphine consumption at first 72 h. Secondary outcome objectives were morphine requirement, numbers of intake, time to first intake, pain score numerical analog scale (NAS), postoperative analgesia related complications, recovery of intestinal motility, and inflammatory markers. Data were analyzed, rescue morphine analgesia was significantly lower in (BD) group compared with (B) groups as considering total morphine consumption (B 4 ± 1.9, BD 1.5 ± 0.5, P = 0.03), numbers of morphine intake ( P = 0.04), morphine requirement ( P = 0.03), and first time of analgesia intake ( P = 0.04). NAS was significantly lower in group (BD) compared with group (B) group in the first 12 h (NAS 0 - P = 0.001, NAS 1 - P = 0.03). Adding dexmedetomidine improved gut motility, first oral intake without detectable anti-inflammatory effect. Adding dexmedetomidine to bupivacine in a surgically inserted catheter for TAP block in donor hepatectomy reduced morphine consumption without detectable anti-inflammatory effect.
Efficacy of Intrauterine Bakri Balloon Tamponade in Cesarean Section for Placenta Previa Patients.
Cho, Hee Young; Park, Yong Won; Kim, Young Han; Jung, Inkyung; Kwon, Ja-Young
2015-01-01
The aims of this study were to analyze the predictive factors for the use of intrauterine balloon insertion and to evaluate the efficacy and factors affecting failure of uterine tamponade with a Bakri balloon during cesarean section for abnormal placentation. We reviewed the medical records of 137 patients who underwent elective cesarean section for placenta previa between July 2009 and March 2014. Cesarean section and Bakri balloon insertion were performed by a single qualified surgeon. The Bakri balloon was applied when blood loss during cesarean delivery exceeded 1,000 mL. Sixty-four patients (46.7%) required uterine balloon tamponade during cesarean section due to postpartum bleeding from the lower uterine segment, of whom 50 (78.1%) had placenta previa totalis. The overall success rate was 75% (48/64) for placenta previa patients. Previous cesarean section history, anterior placenta, peripartum platelet count, and disseminated intravascular coagulopathy all significantly differed according to balloon success or failure (all p<0.05). The drainage amount over 1 hour was 500 mL (20-1200 mL) in the balloon failure group and 60 mL (5-500 mL) in the balloon success group (p<0.01). Intrauterine tamponade with a Bakri balloon is an adequate adjunct management for postpartum hemorrhage following cesarean section for placenta previa to preserve the uterus. This method is simple to apply, non-invasive, and inexpensive. However, possible factors related to failure of Bakri balloon tamponade for placenta previa patients such as prior cesarean section history, anterior placentation, thrombocytopenia, presence of DIC at the time of catheter insertion, and catheter drainage volume more than 500 mL within 1 hour of catheter placement should be recognized, and the next-line management should be prepared in advance.
Efficacy of Intrauterine Bakri Balloon Tamponade in Cesarean Section for Placenta Previa Patients
Cho, Hee Young; Park, Yong Won; Kim, Young Han; Jung, Inkyung; Kwon, Ja-Young
2015-01-01
Purpose The aims of this study were to analyze the predictive factors for the use of intrauterine balloon insertion and to evaluate the efficacy and factors affecting failure of uterine tamponade with a Bakri balloon during cesarean section for abnormal placentation. Methods We reviewed the medical records of 137 patients who underwent elective cesarean section for placenta previa between July 2009 and March 2014. Cesarean section and Bakri balloon insertion were performed by a single qualified surgeon. The Bakri balloon was applied when blood loss during cesarean delivery exceeded 1,000 mL. Results Sixty-four patients (46.7%) required uterine balloon tamponade during cesarean section due to postpartum bleeding from the lower uterine segment, of whom 50 (78.1%) had placenta previa totalis. The overall success rate was 75% (48/64) for placenta previa patients. Previous cesarean section history, anterior placenta, peripartum platelet count, and disseminated intravascular coagulopathy all significantly differed according to balloon success or failure (all p<0.05). The drainage amount over 1 hour was 500 mL (20–1200 mL) in the balloon failure group and 60 mL (5–500 mL) in the balloon success group (p<0.01). Conclusion Intrauterine tamponade with a Bakri balloon is an adequate adjunct management for postpartum hemorrhage following cesarean section for placenta previa to preserve the uterus. This method is simple to apply, non-invasive, and inexpensive. However, possible factors related to failure of Bakri balloon tamponade for placenta previa patients such as prior cesarean section history, anterior placentation, thrombocytopenia, presence of DIC at the time of catheter insertion, and catheter drainage volume more than 500 mL within 1 hour of catheter placement should be recognized, and the next-line management should be prepared in advance. PMID:26263014
Variation in use of technology among vascular access specialists: an analysis of the PICC1 survey.
Chopra, Vineet; Kuhn, Latoya; Ratz, David; Winter, Suzanne; Carr, Peter J; Paje, David; Krein, Sarah L
2017-05-15
While the use of technologies such as ultrasound and electrocardiographic (ECG) guidance systems to place peripherally inserted central catheters (PICCs) has grown, little is known about the clinicians who use these tools or their work settings. Using data from a national survey of vascular access specialists, we identified technology users as PICC inserters that: (a) use ultrasound to find a suitable vein for catheter placement; (b) measure catheter-to-vein ratio; and (c) use ECG for PICC placement. Individual and organizational-level characteristics between technology users versus non-users were assessed. Bivariable comparisons were made using Chi-squared or Fisher's exact tests; two-sided alpha with p<0.05 was considered statistically significant. Of the 2762 PICC inserters who accessed the survey, 1518 (55%) provided information regarding technology use. Technology users reported greater experience than non-technology users, with a higher percentage stating they had placed >1000 PICCs (55% vs. 45%, p<0.001). A significantly greater percentage of technology users also reported being certified in vascular access by an external agency than non-technology users (75% vs. 63%, p<0.001). Technology users were more often part of vascular access teams with ≥10 members compared to non-technology users (35% vs. 22%, p<0.001). Some practices also varied between the two groups: for example, use of certain securement devices and dressings differed between technology users and non-users (p<0.001). Technology use by vascular access clinicians while placing PICCs is associated with clinician characteristics, work setting and practice factors. Understanding whether such differences influence clinical care or patient outcomes appears necessary.
Ruggeri, Andrea; Enseñat, Joaquim; Prats-Galino, Alberto; Lopez-Rueda, Antonio; Berenguer, Joan; Cappelletti, Martina; De Notaris, Matteo; d'Avella, Elena
2017-03-01
OBJECTIVE Neurosurgical management of many vascular and neoplastic lesions necessitates control of the internal carotid artery (ICA). The aim of this study was to investigate the feasibility of achieving control of the ICA through the endoscopic endonasal approach by temporary occlusion with a Fogarty balloon catheter. METHODS Ten endoscopic endonasal paraseptal approaches were performed on cadaveric specimens. A Fogarty balloon catheter was inserted through a sellar bony opening and pushed laterally and posteriorly extraarterially along the paraclival carotid artery. The balloon was then inflated, thus achieving temporary occlusion of the vessel. The position of the catheter was confirmed with CT scans, and occlusion of the ICA was demonstrated with angiography. The technique was performed in 2 surgical cases of pituitary macroadenoma with cavernous sinus invasion. RESULTS Positioning the Fogarty balloon catheter at the level of the paraclival ICA was achieved in all cadaveric dissections and surgical cases through a minimally invasive, quick, and safe approach. Inflation of the Fogarty balloon caused interruption of blood flow in 100% of cases. CONCLUSIONS Temporary occlusion of the paraclival ICA performed through the endoscopic endonasal route with the aid of a Fogarty balloon catheter may be another maneuver for dealing with intraoperative ICA control. Further clinical studies are required to prove the efficacy of this method.
Levin, Ricardo; Leacche, Marzia; Petracek, Michael R; Deegan, Robert J; Eagle, Susan S; Thompson, Annemarie; Pretorius, Mias; Solenkova, Nataliya V; Umakanthan, Ramanan; Brewer, Zachary E; Byrne, John G
2010-08-01
In this study, the therapeutic use of pacing pulmonary artery catheters in association with minimally invasive cardiac surgery was evaluated. A retrospective study. A single institutional university hospital. Two hundred twenty-four consecutive patients undergoing minimally invasive cardiac surgery through a small (5-cm) right anterolateral thoracotomy using fibrillatory arrest without aortic cross-clamping. Two hundred eighteen patients underwent mitral valve surgery (97%) alone or in combination with other procedures. Six patients underwent other cardiac operations. In all patients, the pacing pulmonary artery catheter was used intraoperatively to induce ventricular fibrillation during the cooling period, and in the postoperative period it also was used in 37 (17%) patients who needed to be paced, mainly for bradyarrhythmias (51%). There were no complications related to the insertion of the catheters. Six (3%) patients experienced a loss of pacing capture, and 2 (1%) experienced another complication requiring the surgical removal of the catheter. Seven (3%) patients needed postoperative implantation of a permanent pacemaker. In combination with minimally invasive cardiac surgery, pacing pulmonary artery catheters were therapeutically useful to induce ventricular fibrillatory arrest intraoperatively and for obtaining pacing capability in the postoperative period. Their use was associated with a low number of complications. Copyright 2010 Elsevier Inc. All rights reserved.
Stevenson, André T; Reese, Laura M; Hill, Tanner K; McGuire, Jeffrey; Mohs, Aaron M; Shekhar, Raj; Bickford, Lissett R; Whittington, Abby R
2015-06-01
Peripherally inserted central catheters (PICCs) are hollow polymeric tubes that transport nutrients, blood and medications to neonates. To determine proper PICC placement, frequent X-ray imaging of neonates is performed. Because X-rays pose severe health risks to neonates, safer alternatives are needed. We hypothesize that near infrared (NIR) polymer composites can be fabricated into catheters by incorporating a fluorescent dye (IRDye 800CW) and visualized using NIR imaging. To fabricate catheters, polymer and dye are dry mixed and pressed, sectioned, and extruded to produce hollow tubes. We analyzed surface roughness, stiffness, dye retention, NIR contrast intensity, and biocompatibility. The extrusion process did not significantly alter the mechanical properties of the polymer composites. Over a period of 23 days, only 6.35 ± 5.08% dye leached out of catheters. The addition of 0.025 wt% dye resulted in a 14-fold contrast enhancement producing clear PICC images at 1 cm under a tissue equivalent. The addition of IRDye 800CW did not alter the biocompatibility of the polymer and did not increase adhesion of cells to the surface. We successfully demonstrated that catheters can be imaged without the use of harmful radiation and still maintain the same properties as the unaltered medical grade equivalent. Copyright © 2015 Elsevier Ltd. All rights reserved.
Ista, Erwin; van der Hoven, Ben; Kornelisse, René F; van der Starre, Cynthia; Vos, Margreet C; Boersma, Eric; Helder, Onno K
2016-06-01
Central-line-associated bloodstream infections (CLABSIs) are a major problem in intensive care units (ICUs) worldwide. We aimed to quantify the effectiveness of central-line bundles (insertion or maintenance or both) to prevent these infections. We searched Embase, MEDLINE OvidSP, Web-of-Science, and Cochrane Library to identify studies reporting the implementation of central-line bundles in adult ICU, paediatric ICU (PICU), or neonatal ICU (NICU) patients. We searched for studies published between Jan 1, 1990, and June 30, 2015. For the meta-analysis, crude estimates of infections were pooled by use of a DerSimonian and Laird random effect model. The primary outcome was the number of CLABSIs per 1000 catheter-days before and after implementation. Incidence risk ratios (IRRs) were obtained by use of random-effects models. We initially identified 4337 records, and after excluding duplicates and those ineligible, 96 studies met the eligibility criteria, 79 of which contained sufficient information for a meta-analysis. Median CLABSIs incidence were 5·7 per 1000 catheter-days (range 1·2-46·3; IQR 3·1-9·5) on adult ICUs; 5·9 per 1000 catheter-days (range 2·6-31·1; 4·8-9·4) on PICUs; and 8·4 per 1000 catheter-days (range 2·6-24·1; 3·7-16·0) on NICUs. After implementation of central-line bundles the CLABSI incidence ranged from 0 to 19·5 per 1000 catheter-days (median 2·6, IQR 1·2-4·4) in all types of ICUs. In our meta-analysis the incidence of infections decreased significantly from median 6·4 per 1000 catheter-days (IQR 3·8-10·9) to 2·5 per 1000 catheter-days (1·4-4·8) after implementation of bundles (IRR 0·44, 95% CI 0·39-0·50, p<0·0001; I(2)=89%). Implementation of central-line bundles has the potential to reduce the incidence of CLABSIs. None. Copyright © 2016 Elsevier Ltd. All rights reserved.
Gordy, Stephanie; Rowell, Susan
2013-01-01
Vascular air embolism is a rare but potentially fatal event. It may occur in a variety of procedures and surgeries but is most often associated as an iatrogenic complication of central line catheter insertion. This article reviews the incidence, pathophysiology, diagnosis, treatment, and prevention of this phenomenon. PMID:23724390
Translating research into practice. Implications of the Thunder Project II.
Thompson, C L; White, C; Wild, L R; Morris, A B; Perdue, S T; Stanik-Hutt, J; Puntillo, K A
2001-12-01
The Thunder Project II study described procedural pain in a variety of acute and critical care settings. The procedures studied were turning, tracheal suctioning, wound drain removal, nonburn wound dressing change, femoral sheath removal, and central venous catheter insertion. Turning had the highest mean pain intensity, whereas femoral sheath removal and central venous catheter insertion had the least pain intensity in adults. Nonwound dressing change had the highest pain intensity for teenagers. Pain occurred in procedures that are often repeated several times a day as well as in those that may be single events. There is a wide range of pain responses to any of these procedures; as a result, standardized and thoughtful pain, and distress assessments are warranted. Planning of care, including the use of preemptive analgesic interventions, needs to be individualized. Future studies are needed to describe patient responses to other commonly performed nursing procedures and to identify effective interventions for reducing procedural pain and distress.
Multisensory System for the Detection and Localization of Peripheral Subcutaneous Veins
Fernández, Roemi; Armada, Manuel
2017-01-01
This paper proposes a multisensory system for the detection and localization of peripheral subcutaneous veins, as a first step for achieving automatic robotic insertion of catheters in the near future. The multisensory system is based on the combination of a SWIR (Short-Wave Infrared) camera, a TOF (Time-Of-Flight) camera and a NIR (Near Infrared) lighting source. The associated algorithm consists of two main parts: one devoted to the features extraction from the SWIR image, and another envisaged for the registration of the range data provided by the TOF camera, with the SWIR image and the results of the peripheral veins detection. In this way, the detected subcutaneous veins are mapped onto the 3D reconstructed surface, providing a full representation of the region of interest for the automatic catheter insertion. Several experimental tests were carried out in order to evaluate the capabilities of the presented approach. Preliminary results demonstrate the feasibility of the proposed design and highlight the potential benefits of the solution. PMID:28422075
Kravchick, Sergey; Bunkin, Igor; Peled, Ronit; Yulish, Eugeny; Ben-Dor, David; Kravchenko, Yakov; Cytron, Shmuel
2007-10-01
Elevated PSA value in the presence of an indwelling catheter is still an enigma. The aims of this prospective study were: to investigate the reliability of elevated PSA levels in patients with normal DRE and indwelling catheter after AUR; to assess the impact of preoperative TRUS-biopsy in detecting prostate cancer in such circumstances; to estimate the crucial duration of follow-up period. 63 patients were included in the study. PSA was assessed 5 days after catheter insertion. All patients failed to void without catheter and have been scheduled for surgery. TRUS-biopsy was performed before operation. All patients underwent surgery at least two weeks after prostate biopsies. Postoperative follow-up visits continued for at least 7 years. Biopsies were taken when indicated by persistently elevated PSA or an abnormal DRE. Mean PSA before catheter insertion differed significantly from PSA obtained on the 5(th) day after AUR (p = 0.001). Mean prostate volume calculated on TRUS was 80.5 +/- 28 ml. Mean duration of indwelling catheter placement was 37.8 +/- 7.97 days. Mean delay in operative treatment as a result of preoperative evaluation was 23.548 +/- 2.487 days. Carcinoma was detected in 13 patients, while clinically insignificant cancer was present in 31% (4 patients). It must be also emphasized that 38% of patients with carcinoma were >70 year-old. Preoperative TRUS-biopsy and postoperative pathologic exam diagnosed carcinoma in 5 patients (2 and 3 respectively). During 42 months of 7-year follow-up cancer was revealed in 8 patients. Mean PSA value in the follow-up period was significantly elevated in patients with carcinoma: 5.99 +/- 3.34 v/s 2.34 +/- 1.68 ng/ml (p = 0.007) and was the strongest predictor for cancer detection (p = 0.001). The detection rate of clinically significant cancer on preoperative biopsies postoperative pathologic exam in patients with AUR and indwelling catheter is low. These patients could be safely operated on without any delay. However, in order to detect clinically important cancer in the peripheral zone a postoperative monitoring period of should be recommended: starting 6 months after operation and continuing subsequently for at least 4 years. Postoperative PSA level is the strongest predictor of cancer detection and could be usefully employed in these patients. AUR and in the patients with large prostate cause elevated PSA. Cancer detection rate on preoperative biopsies is low in these patients. Long postoperative monitoring period should be strongly recommended.
Infection and natural history of emergency department-placed central venous catheters.
LeMaster, Christopher H; Schuur, Jeremiah D; Pandya, Darshan; Pallin, Daniel J; Silvia, Jennifer; Yokoe, Deborah; Agrawal, Ashish; Hou, Peter C
2010-11-01
Central line-associated bloodstream infection (CLABSI, hereafter referred to in this paper as "bloodstream infection") is a leading cause of hospital-acquired infection. To our knowledge, there are no previously published studies designed to determine the rate of bloodstream infection among central venous catheters placed in the emergency department (ED). We design a retrospective chart review methodology to determine bloodstream infection and duration of catheterization for central venous catheters placed in the ED. Using hospital infection control, administrative, and ED billing databases, we identified patients with central venous catheters placed in the ED between January 1, 2007, and December 31, 2008, at one academic, urban ED with an annual census of 57,000. We performed a structured, explicit chart review to determine duration of catheterization and confirm bloodstream infection. We screened 4,251 charts and identified 656 patients with central venous catheters inserted in the ED, 3,622 catheter-days, and 7 bloodstream infections. The rate of bloodstream infection associated with central venous catheters placed in the ED was 1.93 per 1,000 catheter-days (95% confidence interval 0.50 to 3.36). The mean duration of catheterization was 5.5 days (median 4; range 1 to 29 days). Among infected central venous catheters, the mean duration of catheterization was 8.6 days (median 7; range 2 to 19 days). A total of 667 central venous catheters were placed in the internal jugular (392; 59%), subclavian (145; 22%), and femoral (130; 19%) veins. The sensitivity of using ED procedural billing code for identifying ED-placed central venous catheters among patients subsequently admitted to any ICU was 74.9% (95% confidence interval 71.4% to 78.3%). The rate of ED bloodstream infection at our institution is similar to current rates in ICUs. Central venous catheters placed in the ED remain in admitted patients for a substantial period. Copyright © 2010 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.
Ablordeppey, Enyo A.; Drewry, Anne M.; Beyer, Alexander B.; Theodoro, Daniel L.; Fowler, Susan A.; Fuller, Brian M.; Carpenter, Christopher R.
2016-01-01
Objective We performed a systematic review and meta-analysis to examine the accuracy of bedside ultrasound for confirmation of central venous catheter position and exclusion of pneumothorax compared to chest radiography. Data Sources PubMed, EMBASE, Cochrane Central Register of Controlled Trials, reference lists, conference proceedings and ClinicalTrials.gov Study Selection Articles and abstracts describing the diagnostic accuracy of bedside ultrasound compared with chest radiography for confirmation of central venous catheters in sufficient detail to reconstruct 2×2 contingency tables were reviewed. Primary outcomes included the accuracy of confirming catheter positioning and detecting a pneumothorax. Secondary outcomes included feasibility, inter-rater reliability, and efficiency to complete bedside ultrasound confirmation of central venous catheter position. Data Extraction Investigators abstracted study details including research design and sonographic imaging technique to detect catheter malposition and procedure-related pneumothorax. Diagnostic accuracy measures included pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio. Data Synthesis 15 studies with 1553 central venous catheter placements were identified with a pooled sensitivity and specificity of catheter malposition by ultrasound of 0.82 [0.77, 0.86] and 0.98 [0.97, 0.99] respectively. The pooled positive and negative likelihood ratios of catheter malposition by ultrasound were 31.12 [14.72, 65.78] and 0.25 [0.13, 0.47]. The sensitivity and specificity of ultrasound for pneumothorax detection was nearly 100% in the participating studies. Bedside ultrasound reduced mean central venous catheter confirmation time by 58.3 minutes. Risk of bias and clinical heterogeneity in the studies were high. Conclusions Bedside ultrasound is faster than radiography at identifying pneumothorax after central venous catheter insertion. When a central venous catheter malposition exists, bedside ultrasound will identify four out of every five earlier than chest radiography. PMID:27922877
Radić, Josipa; Ljutić, Dragan; Radić, Mislav; Kovačić, Vedran; Sain, Milenka; Dodig-Ćurković, Katarina
2011-01-01
Change in cognitive function is one of the well-known consequences of the end-stage renal disease (ESRD). The aim of this study was to determine the effect of hemodialysis (HD) and continuous ambulatory peritoneal dialysis (CAPD) on cognitive and motor functions. In this cross-sectional study, cognitive and motor functions were investigated in a selected population of 42 patients with ESRD (22 patients on chronic HD and 20 patients on CAPD, aged 50.31 ± 11.07 years). Assessment of cognitive and motor functions was performed by Symbol Digit Modalities Test (SDMT) and Complex Reactiometer Drenovac (CRD-series), a battery of computer-generated psychological tests to measure simple visual discrimination of signal location, short-term memory, simple convergent visual orientation, and convergent thinking. The statistically significant difference in cognitive-motor functions between HD and CAPD patients was not found in any of the time-related parameters in all CRD-series tests or SDMT score. Higher serum levels of albumin, creatinine, and calcium were correlated with better cognitive-motor performance among all patients regardless of dialysis modality. The significant correlation between ultrafiltration rate per HD and short-term memory actualization test score (CRD-324 MT) among HD patients was found (r = 0.434, p = 0.025). This study has demonstrated that well-nourished and medically stable HD and CAPD patients without clinical signs of dementia or cognitive impairment and without significant difference in age and level of education performed all tests of cognitive-motor abilities without statistically significant difference.
Costs and added value of haemodialysis and peritoneal dialysis outsourcing agreements.
Lamas Barreiro, J M; Alonso Suárez, M; Saavedra Alonso, J A; Gándara Martínez, A
2011-01-01
Despite the discrepancy in results from Spanish studies on the costs of dialysis, it is assumed that peritoneal dialysis (PD) is more efficient than haemodialysis (HD). To analyse the costs and added value of HD and PD outsourcing agreements in Galicia, the medical transport for HD and the relationship between the cost of the agreement and the cost of consumables used in continuous ambulatory peritoneal dialysis (CAPD) with bicarbonate. The cost of the outsourcing agreements and the staff was obtained from official publications. The cost of PD and medical transport were calculated using health service data for one month and extrapolating it to one year. The cost of CAPD consumables was provided by the suppliers. The added value was calculated from the investments generated for each agreement treating 40 patients. Expressed as patient/year, the mean costs for treatment were €21595 and €25664 in HD and PD, respectively. Medical transport varied between €3323 and €6338, while those of the CAPD agreement and consumables were €19268 and €12057, respectively. The added value was greater with the HD agreement, especially considering the jobs created. One cannot generalise that the cost of PD, which is significantly influenced by prescriptions, is lower than that of HD. It would be appropriate to review the additional cost to consumables in the CAPD agreement. The added value generated by dialysis agreements should be considered in future studies and in health planning. More controlled studies are needed to better understand this issue.
Gulcan, Aynur; Gulcan, Erim; Keles, Mustafa; Aktas, Esin
2016-06-01
We aimed to investigate the frequency of oral yeast colonization (OYC) and the risk factors for patients who received continuous ambulatory peritoneal dialysis (CAPD) or hemodialysis (HD) or were renal transplant recipients (RTRs). The patients admitted to the Nephrology Clinic at Ataturk University Medical School from January through April 2013 were included in the study. A questionnaire about risk factors was filled out, and swab cultures were taken from the tongue surface of each participant. OYC was detected in 32.1% of the RTRs, 40% of the HD patients, 20.9% of the CAPD patients, and 18% of the healthy control (HC) group. Of the 42 yeast strains isolated from the renal replacement therapy groups, 26 strains (61.9%) were Candida albicans, nine (21.4%) were Candida glabrata, two (4.7%) were Candida krusei, two (4.7%) were Candida kefyr, one (2.38%) was Candida parapsilosis, and two (4.7%) were Geotrichum candidum. Risk factors for OYC in the RTRs group included antibiotic use and the presence of dental prostheses; however, in patients with chronic renal failure undergoing CAPD, only the presence of dental prostheses was found to be a statistically significant risk factor. Although OYC was mostly detected in patients with chronic kidney disease (undergoing HD, a variety of isolated yeast strains in the RTRs was noted. The rates of OYC and isolated Candida species in CAPD were similar to those of the HC group. Copyright © 2016 Elsevier Ltd. All rights reserved.
Holmberg, Mathias J; Andersen, Lars W; Graver, Amanda; Wright, Sharon B; Yassa, David; Howell, Michael D; Donnino, Michael W; Cocchi, Michael N
2015-12-01
The aim of this study was to investigate whether clinicians can estimate the length of time a central venous catheter (CVC) will remain in place and to identify variables that may predict CVC duration. We conducted a prospective study of patients admitted to the intensive care unit over a 1-year period. Clinicians estimated the anticipated CVC duration at time of insertion. We collected demographics, medical history, type of intensive care unit, anatomical site of CVC placement, vital signs, laboratory values, Sequential Organ Failure Assessment score, mechanical ventilation, and use of vasopressors. Pearson correlation coefficient was used to assess the correlation between estimated and actual CVC time. We performed multivariable logistic regression to identify predictors of long duration (>5 days). We enrolled 200 patients; median age was 65 years (quartiles 52, 75); 91 (46%) were female; and mortality was 24%. Correlation between estimated and actual CVC time was low (r=0.26; r2=0.07; P<.001). Mechanical ventilation (odds ratio, 2.20; 95% confidence interval, 1.22-3.97; P=.009) at time of insertion and a medical history of cancer (odds ratio, 0.35; 95% confidence interval, 0.16-0.75; P=.007) were significantly associated with long duration. Our results suggest a low correlation between clinician prediction and actual CVC duration. We did not find any strong predictors of long CVC duration identifiable at the time of insertion. Copyright © 2015 Elsevier Inc. All rights reserved.
2013-01-01
Central venous catheters (CVCs) are indispensable in modern pediatric medicine. CVCs provide secure vascular access, but are associated with a risk of severe complications, in particular bloodstream infection. We provide a review of the recent literature about the diagnostic and therapeutic challenges of catheter-related bloodstream infection (CRBSI) in children and its prevention. Variations in blood sampling and limitations in blood culturing interfere with accurate and timely diagnosis of CRBSI. Although novel molecular testing methods appear promising in overcoming some of the present diagnostic limitations of conventional blood sampling in children, they still need to solidly prove their accuracy and reliability in clinical practice. Standardized practices of catheter insertion and care remain the cornerstone of CRBSI prevention although their implementation in daily practice may be difficult. Technology such as CVC impregnation or catheter locking with antimicrobial substances has been shown less effective than anticipated. Despite encouraging results in CRBSI prevention among adults, the goal of zero infection in children is still not in range. More high-quality research is needed in the field of prevention, accurate and reliable diagnostic measures and effective treatment of CRBSI in children. PMID:24041298
Morohashi, Toru; Ogura, Takahiro; Inamura, Rie; Kazama, Tomiei
2012-06-01
The central vein catheter-related infection and thrombosis are comparatively frequent and may cause a serious complication. AVA3Xi was taken into custody to the internal jugular vein, and the patient suffured from thrombophlebitis on the seventh day after the operation. A 73-year-old woman 151 cm tall and weighing 50 kg was scheduled for pancreatoduodenectomy under propofol-remifentanil anesthesia combined with epidural anesthesia (operating time 9 hours and 21 minutes, anesthetizing time 12 hours and 1 minute). The past history of the thrombosis was not present, and it was especially unquestionable for the trap including the preoperative testing and the central venous catheter insertion. The time course after the operation was also good. But the patient claimed the stiffness of the cervix on the postoperative seventh day; fever and shivering were also accompanied. S. epidermidis was identified by the blood culture. Thrombophlebitis was diagnosed with CT. It is necessary to choose an appropriate catheter and endeavor for the prevention and early detection of the blood clot formation to prevent catheter-related infection and thrombosis with cooperation with the surgeon.
Rao, Neal M; Raychev, Radoslav; Kim, Doojin; Liebeskind, David S
2012-11-01
Posterior reversible encephalopathy syndrome (PRES) is a condition characterized by reversible symptoms including headache, visual disturbances, focal neurological deficits, altered mentation, and seizures. It has been associated with circumstances that may affect the cerebrovascular system, such as hypertension, eclampsia, and immunosuppression with calcineurin inhibitors. The underlying etiology of PRES has remained unclear; however, cerebrovascular autoregulatory dysfunction, hyperperfusion, and endothelial activation have been implicated. We describe a case of a young patient with lung transplant, who presented with headache, acute binocular blindness, and seizure immediately after infusion of saline through a peripherally inserted central catheter line, which inadvertently terminated cephalad in the left internal jugular vein, near the jugular foramen. Subsequent brain magnetic resonance imaging revealed vasogenic edematous lesions in a pattern consistent with PRES--a diagnosis supported by his constellation of symptoms, history of lung transplantation on tacrolimus immunosuppression, and relative hypertension. This is the first reported case describing the development of PRES after the insertion of a peripherally inserted central catheter line. The development of PRES in a typical high-risk patient immediately after cerebral venous outflow obstruction implicates the role of the cerebral venous system and provides potential insight into the mechanism of this disorder that remains of unclear pathogenesis.
Shackley, David Clifford; Whytock, Cameron; Parry, Gareth; Clarke, Laurence; Vincent, Charles; Harrison, Abigail; John, Amber; Provost, Lloyd; Power, Maxine
2017-06-23
Harm from catheter-associated urinary tract infections is a common, potentially avoidable, healthcare complication. Variation in catheter prevalence may exist and provide opportunity for reducing harm, yet to date is poorly understood. This study aimed to determine variation in the prevalence of urinary catheters between patient groups, settings, specialities and over time. A prospective study (July 2012 to April 2016) of National Health Service (NHS) patients surveyed by healthcare professionals, following a standardised protocol to determine the presence of a urinary catheter and duration of use, on 1 day per month using the NHS Safety Thermometer. 1314 organisations (253 NHS trusts) and 9 266 284 patients were included. Overall, 12.9% of patients were catheterised, but utilisation varied. There was higher utilisation of catheters in males (15.7% vs 10.7% p<0.001) and younger people (18-70 year 14.0% vs >70 year 12.8% p<0.001), utilisation was highest in hospital settings (18.6% p<0.001), particularly in critical care (76.6% p<0.001). Most catheters had been in situ <28 days (72.9% p<0.001). No clinically significant changes were seen over time in any setting or specialty. Catheter prevalence in patients receiving NHS-funded care varies according to gender, age, setting and specialty, being most prevalent in males, younger people, hospitals and critical care. Utilisation has changed only marginally over 46 months, and further guidance is indicated to provide clarity for clinicians on the insertion and removal of catheters to supplement the existing guidance on care. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Permanent catheters for recurrent ascites-a critical and systematic review of study methodology.
Christensen, Lars; Wildgaard, Lorna; Wildgaard, Kim
2016-06-01
Management of refractory ascites traditionally includes medical treatment with diuretics or intermittent paracentesis. Patients with recurrent ascites may benefit from the use of permanent intra-abdominal catheters with more frequent drainage without hospitalization. The objective was to systematically asses the methodology of factors and endpoints reported in studies investigating permanent catheters for recurrent ascites treatment. Using a systematic search strategy, we critically assessed the methodology when treating refractory ascites using a permanent catheter. Studies critically assessed included both retro- and prospective studies. A total of 715 unique articles were found via PubMed, The Cochrane Library and Embase. Twenty-nine studies (tunnelled catheter = 12, peritoneal ports = 6 and peritoneovenous shunts = 11) with three distinct types of permanent catheters fulfilled the inclusion criteria. Only three studies reported technical success less than 100 %. Data on complications and treatment were not available in all papers; peritonitis (48 %), cellulitis (41 %), prophylactic antibiotics (48 %) and complications to catheter insertion were difficult to distinguish from advanced co-morbidity of patients. Thirteen studies (45 %) reported some type of evaluating patient experience or functional outcome, but only three studies used validated reproducible scales when assessing outcomes. Fifteen of the 29 studies included 30 patients or less. Knowledge is limited because complications and outcomes are poorly defined. The expected increase in catheter treatment of refractory ascites necessitates comparative studies, using validated patient-related outcomes, and the reporting of unambiguous complications. A proposal of variables to include in future studies is presented.
Lennox, Pamela H; Umedaly, Hamed S; Grant, Raymer P; White, S Adrian; Fitzmaurice, Brett G; Evans, Kenneth G
2006-10-01
The purpose of this study was to assess the validity of using a pulsatile, pressure waveform transduced from the epidural space through an epidural needle or catheter to confirm correct placement for maximal analgesia and to compare 3 different types of catheters' ability to transduce a waveform. A single-center, prospective, randomized trial. A tertiary-referral hospital. Eighty-one patients undergoing posterolateral thoracotomy who required a thoracic epidural catheter for postoperative pain management. Each epidural needle and each epidural catheter was transduced to determine if there was a pulsatile waveform exhibited. Sensitivity of the pulsatile waveform transduced through an epidural needle to identify correct placement of the epidural needle and the sensitivity of each catheter type to identify placement were compared. In 79 of 81 cases (97.5%), the waveform transduced directly through the epidural needle had a pulsatile characteristic as determined by blinded observers. In a total of 53 of 81 epidural catheters (65.4%), the transduced waveform displayed pulsations. Twenty-four of 27 catheters in group S-P/Sims Portex (Smiths Medical MD, Inc, St Paul, MN) (88.9%) transduced a pulsatile tracing from the epidural space, a significantly greater percentage than in the other 2 groups (p = 0.02). The technique of transducing the pressure waveform from the epidural needle inserted in the epidural space is a sensitive and reliable alternative to other techniques for confirmation of correct epidural catheter placement. The technique is simple, sensitive, and inexpensive and uses equipment available in any operating room.
Gulur, P; Tsui, B; Pathak, R; Koury, K M; Lee, H
2015-05-01
Epidural haematoma is a rare but potentially catastrophic complication associated with epidural catheterization. The times of insertion and removal of epidural catheters are high-risk periods for epidural haematoma formation, especially with abnormal coagulation parameters. There is a lack of data on the incidence of epidural haematoma in patients with abnormal coagulation parameters. A retrospective analysis was undertaken from 2002 to 2009 on patients with an epidural catheter. Queries were performed on the coagulation parameters for the dates of placement and removal of the catheters and on all documented epidural haematoma cases. During the study period, 11 600 epidural catheters were placed. In the setting of abnormal coagulation parameters, 278 (2.4%) epidural catheters were placed and 351 (3%) were removed. Two epidural haematomas occurred; both patients had epidural catheters and spinal drains placed for vascular procedures with abnormal coagulation parameters after operatation. The haematomas occurred after removal of the catheters. Based on our study, the incidence of epidural haematoma in patients with abnormal coagulation parameters is 1 in 315 patients, with the lower limit of the 95% confidence interval at 87 and the upper limit at 2597. The risk of epidural haematoma is clearly elevated with abnormal coagulation parameters. Our data suggest that as the incidence of epidural haematoma with neuraxial access in patients with abnormal coagulation is not 100%, individual risk-benefit evaluations are warranted. © The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Wen, Jie; Yu, Qun; Chen, Haiyan; Chen, Niannian; Huang, Shourong; Cai, Wei
2017-01-01
The placement of a peripherally inserted central venous catheter (PICC) is an essential procedure in neonatal intensive care units (NICU). The aim of this study was to determine the risk of PICC complications in NICU, and further identify the effects of PICC complications on body weight gain in premature infants. A total of 304 premature infants who had a PICC inserted in NICU were enrolled in this study. The weight-for-age z-score (WAZ) at the time of PICC insertion and removal were calculated, and changes of WAZ in different groups were compared using a t-test. Risk factors for PICC complications were assessed using the chi-squared test and multiple logistic regression analysis. Thirty (9.97%) PICCs were removed due to complications. Of them, 14 PICCs were removed because of non-infectious complications and 16 PICCs were removed for central-line-associated bloodstream infections (CLABSIs). Multiple logistic regression analysis showed that premature infants with birth weight >1,500 g were less likely to have PICC complications than infants with birth weight <=1,500 g (OR, 0.29; 95% CI: 0.10-0.82; p=0.020). In addition, the changes in WAZ between PICC insertion and removal were significantly different in both infectious (-0.144±0.122, p<0.005) and non-infectious (-0.65±0.528, p<0.001) complications groups, compared with the no complications group (0.291±0.552). Findings from this study suggest that birth weight is a risk factor for PICC-associated complications in the NICU, and both infectious and non-infectious PICC complications are associated with poor body weight gain in premature infants.
Zhao, Ruiyi; Chen, Chunfang; Jin, Jingfen; Sharma, Komal; Jiang, Nan; Shentu, Yingqin; Wang, Xingang
2016-06-01
The use of peripherally inserted central catheters (PICCs) provides important central venous accesses for clinical treatments, tests and monitoring. Compared with the traditional methods, intracardiac electrocardiogram (ECG)-guided method has the potential to guide more accurate tip positioning of PICCs. This study aimed to clinically evaluate the effectiveness of an intracardiac ECG to guide the tip positioning by monitoring characteristic P-wave changes. In this study, eligible patients enrolled September 2011 to May 2012 according to the inclusion and exclusion criteria received the catheterization monitored by intracardiac ECG. Then chest radiography was performed to check the catheter position. The results revealed that, with 117 eligible patients, all bar one patient who died (n = 116) completed the study, including 60 males and 56 females aged 51.2 ± 15.1 years. Most (n = 113, > 97%) had characteristic P-wave changes. The intracardiac ECG-guided positioning procedure achieved correct placement for 112 patients (96.56%), demonstrating 99.12% sensitivity and 100% specificity. In conclusion, the intracardiac ECG can be a promising technique to guide tip positioning of PICCs. However, since the sample size in this study is limited, more experience and further study during clinical practice are needed to demonstrate achievement of optimal catheterization outcomes. © 2015 John Wiley & Sons Australia, Ltd.
Johnson, T
2010-12-01
Thoracic epidural catheter placement is an example of a demanding and high-risk clinical skill that junior anaesthetists need to learn by experience and under the supervision of consultants. This learning is known to present challenges that require further study. Ten consultant and 10 trainee anaesthetists in a teaching hospital were interviewed about teaching and learning this skill in the operating theatre, and a phenomenological analysis of their experience was performed. Trainee participation was limited by time pressure, lack of familiarity with consultants, and consultants' own need for clinical experience. There was a particular tension between safe and effective consultant practice and permitting trainees' independence. Three distinct stages of participation and assistance were identified from reports of ideal practice: early (part-task or basic procedure, consultant always present giving instruction and feedback), middle (independent practice with straightforward cases without further instruction), and late (skill extension and transfer). Learning assistance provided by consultants varied, but it was often not matched to the trainees' stages of learning. Negotiation of participation and assistance was recognized as being useful, but it did not happen routinely. There are many obstacles to trainees' participation in thoracic epidural catheter insertion, and learning assistance is not matched to need. A more explicit understanding of stages of learning is required to benefit the learning of this and other advanced clinical skills.
Peripherally Inserted Central Catheters in Pediatric Patients: To Repair or Not Repair
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gnannt, Ralph, E-mail: ralph.gnannt@usz.ch; Patel, Premal; Temple, Michael
IntroductionPreservation of venous access in children is a major concern in pediatric interventional radiology. If a peripherally inserted central catheter (PICC) breaks, there are two options: repair the line with a repair kit or exchange the line over a wire in the interventional suite. The purpose of this study is to assess the outcome of PICC repairs in children and to compare these with the outcomes of PICC exchange.Materials and MethodsThis is a single-center, retrospective study of central line-associated bloodstream infection (CLABSI) following management of externally broken PICCs (2010–2014). The occurrence of CLABSI within 30 days after repair (Group A) ormore » exchange (Group B) of a line was analyzed, as well as PICCs exchanged following an initial and failed repair.ResultsA total of 235 PICC breaks were included in the study, of which 161 were repaired, and 116 of whom were successful (68%, Group A). No repair was performed in 74 PICCs—55/74 of these were exchanged over a wire (74%, Group B), and 19/74 lines were removed. The 30 days post-repair CLABSI rate (Group A) was 2.0 infections per 1000 catheter days, and the calculated risk was 4.3%. In comparison the 30 days post-exchange CLABSI rate (Group B) was 4.0 per 1000 catheter days and the calculated risk 10.9%. This difference was significant when adjusted for antibiotic use (OR 3.87; 95% CI 1.07–14.0, p = 0.039).ConclusionThe results of this study support repairing a broken PICC instead of removing or replacing the line.« less
Rotzinger, Roman; Gebauer, Bernhard; Schnapauff, Dirk; Streitparth, Florian; Wieners, Gero; Grieser, Christian; Freyhardt, Patrick; Hamm, Bernd; Maurer, Martin H
2017-12-01
Background Placement of central venous port catheters (CVPS) and peripherally inserted central catheters (PICC) is an integral component of state-of-the-art patient care. In the era of increasing cost awareness, it is desirable to have more information to comprehensively assess both procedures. Purpose To perform a retrospective analysis of interventional radiologic implantation of CVPS and PICC lines in a large patient population including a cost analysis of both methods as well as an investigation the learning curve in terms of the interventions' durations. Material and Methods All CVPS and PICC line related interventions performed in an interventional radiology department during a three-year period from January 2011 to December 2013 were examined. Documented patient data included sex, venous access site, and indication for CVPS or PICC placement. A cost analysis including intervention times was performed based on the prorated costs of equipment use, staff costs, and expenditures for disposables. The decrease in intervention duration in the course of time conformed to the learning curve. Results In total, 2987 interventions were performed by 16 radiologists: 1777 CVPS and 791 PICC lines. An average implantation took 22.5 ± 0.6 min (CVPS) and 10.1 ± 0.9 min (PICC lines). For CVPS, this average time was achieved by seven radiologists newly learning the procedures after performing 20 CVPS implantations. Total costs per implantation were €242 (CVPS) and €201 (PICC lines). Conclusion Interventional radiologic implantations of CVPS and PICC lines are well-established procedures, easy to learn by residents, and can be implanted at low costs.
Li, Dechun; Du, Hongtao; Shao, Guoqing; Guo, Yongtuan; Lu, Wan; Li, Ruihong
2017-07-01
The application value of small intestine decompression combined with oral feeding in the middle and late period of malignant small bowel obstruction was examined. A total of 22 patients with advanced malignant small bowel obstruction were included in the present study. An ileus tube was inserted via the nose under fluoroscopy into the obstructed small intestine of each patient. At the same time, the insertion depth the of the catheter was adjusted. When the catheter was blocked, small bowel selective angiography was performed to determine the location and cause of the obstruction and the extent of the obstruction, and to determine the length of the small intestine in the site of obstruction, and to select the variety and tolerance of enteral nutrition. We observed the decompression tube flow and ease of intestinal obstruction. In total, 20 patients were treated with oral enteral nutrition after abdominal distension, and 22 cases were treated by the nose to observe the drainage and the relief of intestinal obstruction. The distal end of the catheter was placed in a predetermined position. The symptoms of intestinal obstruction were relieved 1-4 days after decompression. The 22 patients with selective angiography of the small intestine showed positive X-ray signs: 18 patients with oral enteral nutrition therapy had improved the nutritional situation 2 weeks later. In 12 cases, where there was anal defecation exhaust, 2 had transient removal of intestinal obstruction catheter. In conclusion, this comprehensive treatment based on small intestine decompression combined with enteral nutrition is expected to become a new therapeutic approach and method for the treatment of patients with advanced tumor small bowel obstruction.
Mundi, Manpreet S; Edakkanambeth Varayil, Jithinraj; McMahon, Megan T; Okano, Akiko; Vallumsetla, Nishanth; Bonnes, Sara L; Andrews, James C; Hurt, Ryan T
2016-04-01
Parenteral nutrition (PN) is a life-saving therapy for patients with intestinal failure. Safe delivery of hyperosmotic solution requires a central venous catheter (CVC) with tip in the lower superior vena cava (SVC) or at the SVC-right atrium (RA) junction. To reduce cost and delay in use of CVC, new techniques such as intravascular electrocardiogram (ECG) are being used for tip confirmation in place of chest x-ray (CXR). The present study assessed for accuracy of ECG confirmation in home PN (HPN). Records for all patients consulted for HPN from December 17, 2014, to June 16, 2015, were reviewed for patient demographics, diagnosis leading to HPN initiation, and ECG and CXR confirmation. CXRs were subsequently reviewed by a radiologist to reassess location of the CVC tip and identify those that should be adjusted. Seventy-three patients were eligible, and after assessment for research authorization and postplacement CXR, 17 patients (30% male) with an age of 54 ± 14 years were reviewed. In all patients, postplacement intravascular ECG reading stated tip in the SVC. However, based on CXR, the location of the catheter tip was satisfactory (low SVC or SVC-RA junction) in 10 of 17 patients (59%). Due to the high osmolality of PN, CVC tip location is of paramount importance. After radiology review of CXR, we noted that 7 of 17 (41%) peripherally inserted central catheter lines were in an unsatisfactory position despite ECG confirmation. With current data available, intravenous ECG confirmation should not be used as the sole source of tip confirmation in patients receiving HPN. © 2016 American Society for Parenteral and Enteral Nutrition.
[Complications due to peripheral venous catheterization. Prospective study].
Barbut, F; Pistone, T; Guiguet, M; Gaspard, R; Rocher, M; Dousset, C; Meynard, J L; Carbonell, N; Maury, E; Offenstadt, G; Poupon, R; Frottier, J; Valleron, A J; Petit, J C
2003-03-15
Peripheral venous catheter (PVC)-associated complications were prospectively evaluated in a 2 month-study performed in 3 different wards. For each inserted PVC, the following complications were observed daily by an external investigator: tenderness, erythema, swelling or induration, palpable cord and purulence. PVC that were removed were systematically sent to the Microbiology department and analysed according to the semi-quantitative method described by Brun-Buisson et al. A total of 525 PVC (corresponding to 1,036 catheterisation-days) were included. Main clinical complications were erythema (22.1%), tenderness (21.9%), swelling or induration (20.9%), palpable cord (2.7%) and purulence (0.2%). Phlebitis, defined by 2 or more of the following signs: tenderness, erythema, swelling or induration and palpable cord, was observed in 22%. Catheter colonization (> or = 103 CFU/ml) occurred in 13%. Bacteria isolated from colonized catheters were coagulase-negative staphylococci (88.1%), Staphylococcus aureus (7.1%) and Candida sp. (4.8%). Multivariate risk factor analysis showed that age > or = 55 y. (OR = 3.16, p = 0.003), insertion on articulation site (OR = 2.94, p = 0.01) or in jugular vein (OR = 8.18, p = 0.01) and > 72 hour-catheterisation (OR = 4.74, p = 0.0003) were significantly associated with PVC colonization. Risk factors for phlebitis were skin lesions (OR = 1.88, p < 0.016), active infection unrelated to PVC (OR = 2.8, p = 0.001), "poor quality" peripheral vein (OR = 2.46, p < 0.02) and > 72 hour-catherisation (OR = 2.38, p = 0.009). Complications associated with peripheral venous catheters are frequent but remain benign. They could probably be reduced by a systematic change every 72-96 hours as recommended by different guidelines.
2006-01-01
Executive Summary Objective To review the evidence on the effectiveness of hydrophilic catheters for patients requiring intermittent catheterization. Clinical Need There are various reasons why a person would require catheterization, including surgery, urinary retention due to enlargement of the prostate, spinal cord injuries, or other physical disabilities. Urethral catheters are the most prevalent cause of nosocomial urinary tract infections, that is, those that start or occur in a hospital. A urinary tract infection (UTI) occurs when bacteria adheres to the opening of the urethra. Most infections arise from Escherichia coli, from the colon. The bacteria spread into the bladder, resulting in the development of an infection. The prevalence of UTIs varies with age and sex. There is a tenfold increase in incidence for females compared with males in childhood and throughout adult life until around 55 years, when the incidence of UTIs in men and women is equal, mostly as a consequence of prostatic problems in men. Investigators have reported that urethritis (inflammation of the urethra) is found in 2% to 19% of patients practising intermittent catheterization. The Technology Hydrophilic catheters have a polymer coating that binds o the surface of the catheter. When the polymer coating is submersed in water, it absorbs and binds the water to the catheter. The catheter surface becomes smooth and very slippery. This slippery surface remains intact upon insertion into the urethra and maintains lubrication through the length of the urethra. The hydrophilic coating is designed to reduce the friction, as the catheter is inserted with the intention of reducing the risk of urethral damage. It has been suggested that because the hydrophilic catheters do not require manual lubrication they are more sterile and thus less likely to cause infection. Most hydrophilic catheters are prepackaged in sterile water, or there is a pouch of sterile water that is broken and released into the catheter package when the catheter is ready to use. Review Strategy The Medical Advisory Secretariat searched for reports of systematic reviews of randomized controlled trials (RCTs), meta-analyses of RCTs, and RCTs. The following databases were searched: Cochrane Library International Agency for Health Technology Assessment (fourth quarter 2005), Cochrane Database of Systematic Reviews (fourth quarter 2005), Cochrane Central Register of Controlled Trials (fourth quarter 2005), MEDLINE (1966 to the third week of November 2005), MEDLINE In-Process and Other Non-indexed Citations (1966 to November 2005), and EMBASE (1980 to week 49 in 2005). Search terms were urinary catheterization, hydrophilic, intermittent, and bladder catheter. The Medical Advisory Secretariat also conducted Internet searches of Medscape (www.medscape.com) for recent reports on trials that were unpublished but presented at international conferences. In addition, the Web site Current Controlled Trials (www.controlled-trials.com) was searched for ongoing trials on urinary catheterization. Summary of Findings Five RCTs were identified that compared hydrophilic catheters to standard catheters. There was substantial variation across the studies in terms of the reason for catheterization, inclusion criteria, and type of catheter used. Two studies used reusable catheters in the control arm, while the other 3 RCTs used single-use catheters in the control arm. All 5 RCTs focused mainly on males requiring intermittent catheterization. Age varied considerably across studies. One study consisted of young males (mean age 12 years), while another included older males (mean age 71 years). The RCTs reported conflicting results regarding the effectiveness of the hydrophilic catheters compared with standard catheters in terms of rates of UTIs. All 5 RCTs had serious limitations. Two of the studies were small, and likely underpowered to detect significant differences between groups. One RCT reported 12-month follow-up data for all 123 patients even though more than one-half of the patients had dropped out of the study by 12 months. Another RCT had unequal groups at baseline: the patients in the hydrophilic group had twice the mean number of UTIs at baseline compared with the standard catheter group. The fifth RCT used catheters to treat patients with bladder cancer; therefore, the results of their study are not generalizable to the population requiring intermittent catheterization. Two studies did not find significant differences between the hydrophilic and standard catheter groups for patient satisfaction. Another RCT reported conflicting results; however, the overall opinion of the catheters was not significantly different between the treatment groups. A fourth RCT found that the hydrophilic catheters were substantially more comfortable than standard catheters. The fifth RCT did not report results for quality of life or patient satisfaction. Similar to the results for effectiveness, it is not possible to clearly establish if there is a significant difference in patient satisfaction between the patients using hydrophilic catheters and those using standard catheters. Conclusions Patients requiring intermittent catheterization use, on average, 4 to 5 intermittent catheters per day. Patients admitted to hospitals using intermittent catheters typically do not reuse catheters, owing to the potential increased risk of infection in hospital. Patients self-catheterizing at home are more likely to reuse catheters. Standard catheters cost about $1.00 to $1.50/catheter. Hydrophilic catheters cost about $2.00 to $5.00/catheter, depending on the type and whether they have antibiotics inside. All hydrophilic catheters are single-use. At this time there is insufficient evidence to indicate whether hydrophilic catheters are associated with a lower rate of UTIs and improved patient satisfaction among people requiring intermittent catheterization. PMID:23074500
Poulin, Eric; Racine, Emmanuel; Binnekamp, Dirk; Beaulieu, Luc
2015-03-01
In high dose rate brachytherapy (HDR-B), current catheter reconstruction protocols are relatively slow and error prone. The purpose of this technical note is to evaluate the accuracy and the robustness of an electromagnetic (EM) tracking system for automated and real-time catheter reconstruction. For this preclinical study, a total of ten catheters were inserted in gelatin phantoms with different trajectories. Catheters were reconstructed using a 18G biopsy needle, used as an EM stylet and equipped with a miniaturized sensor, and the second generation Aurora(®) Planar Field Generator from Northern Digital Inc. The Aurora EM system provides position and orientation value with precisions of 0.7 mm and 0.2°, respectively. Phantoms were also scanned using a μCT (GE Healthcare) and Philips Big Bore clinical computed tomography (CT) system with a spatial resolution of 89 μm and 2 mm, respectively. Reconstructions using the EM stylet were compared to μCT and CT. To assess the robustness of the EM reconstruction, five catheters were reconstructed twice and compared. Reconstruction time for one catheter was 10 s, leading to a total reconstruction time inferior to 3 min for a typical 17-catheter implant. When compared to the μCT, the mean EM tip identification error was 0.69 ± 0.29 mm while the CT error was 1.08 ± 0.67 mm. The mean 3D distance error was found to be 0.66 ± 0.33 mm and 1.08 ± 0.72 mm for the EM and CT, respectively. EM 3D catheter trajectories were found to be more accurate. A maximum difference of less than 0.6 mm was found between successive EM reconstructions. The EM reconstruction was found to be more accurate and precise than the conventional methods used for catheter reconstruction in HDR-B. This approach can be applied to any type of catheters and applicators.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poulin, Eric; Racine, Emmanuel; Beaulieu, Luc, E-mail: Luc.Beaulieu@phy.ulaval.ca
2015-03-15
Purpose: In high dose rate brachytherapy (HDR-B), current catheter reconstruction protocols are relatively slow and error prone. The purpose of this technical note is to evaluate the accuracy and the robustness of an electromagnetic (EM) tracking system for automated and real-time catheter reconstruction. Methods: For this preclinical study, a total of ten catheters were inserted in gelatin phantoms with different trajectories. Catheters were reconstructed using a 18G biopsy needle, used as an EM stylet and equipped with a miniaturized sensor, and the second generation Aurora{sup ®} Planar Field Generator from Northern Digital Inc. The Aurora EM system provides position andmore » orientation value with precisions of 0.7 mm and 0.2°, respectively. Phantoms were also scanned using a μCT (GE Healthcare) and Philips Big Bore clinical computed tomography (CT) system with a spatial resolution of 89 μm and 2 mm, respectively. Reconstructions using the EM stylet were compared to μCT and CT. To assess the robustness of the EM reconstruction, five catheters were reconstructed twice and compared. Results: Reconstruction time for one catheter was 10 s, leading to a total reconstruction time inferior to 3 min for a typical 17-catheter implant. When compared to the μCT, the mean EM tip identification error was 0.69 ± 0.29 mm while the CT error was 1.08 ± 0.67 mm. The mean 3D distance error was found to be 0.66 ± 0.33 mm and 1.08 ± 0.72 mm for the EM and CT, respectively. EM 3D catheter trajectories were found to be more accurate. A maximum difference of less than 0.6 mm was found between successive EM reconstructions. Conclusions: The EM reconstruction was found to be more accurate and precise than the conventional methods used for catheter reconstruction in HDR-B. This approach can be applied to any type of catheters and applicators.« less
Prasad, A; Cevallos, M E; Riosa, S; Darouiche, R O; Trautner, B W
2009-07-01
Non-randomized pilot trial. To determine whether Escherichia coli 83972-coated urinary catheters in persons with spinal cord injury (SCI) practicing an intermittent catheterization program (ICP) could (1) achieve bladder colonization with this benign organism and (2) decrease the rate of symptomatic urinary tract infection (UTI). Outpatient SCI clinic in a Veterans Affairs hospital (USA). Participants had neurogenic bladders secondary to SCI, were practicing ICP, had experienced at least one UTI and had documented bacteruria within the past year. All participants received a urinary catheter that had been pre-inoculated with E. coli 83972. The catheter was left in place for 3 days and then removed. Participants were followed with urine cultures and telephone calls weekly for 28 days and then monthly until E. coli 83972 was lost from the urine. Outcome measures were (1) the rate of successful bladder colonization, defined as the detection (>or=10(2) cfu ml(-1)) of E. coli 83972 in urine cultures for >3 days after catheter removal and (2) the rate of symptomatic UTI during colonization with E. coli 83972. Thirteen participants underwent 19 insertions of study catheters. Eight participants (62%) became successfully colonized for >3 days after catheter removal. In these 8 participants, the rate of UTI during colonization was 0.77 per patient-year, in comparison with the rate of 2.27 UTI per patient-year before enrollment. E. coli 83972-coated urinary catheters are a viable means of achieving bladder colonization with this potentially protective strain in persons practicing ICP.
Dejmek, M; Kučera, T; Ryšková, L; Čermáková, E; Šponer, P
2017-01-01
PURPOSE OF THE STUDY A very serious complication following joint replacement surgery is periprosthetic joint infection that can be caused by a urinary tract infection. Insertion of an indwelling urinary catheter constitutes a risk factor that may result in urinary tract infections. The aim of this prospective randomised study was to compare the occurrence of significant bacteriuria and symptomatic urinary tract infections during antibiotic prophylaxis at the time of removal of an indwelling urinary catheter by cotrimoxazole in two doses and with no administration of antibiotics. We also monitored the incidence of potential periprosthetic infection following the endoprosthesis implantation. The findings of preoperative urine tests were compared with the declared negative preoperative examination. MATERIAL AND METHODS The study included patients indicated for a total hip or knee replacement with a negative urine culture as a part of the preoperative testing. Where leukocyteria was detected, urine culture by mid-stream clean catch urine was obtained. The second part included patients, in whom an indwelling urinary catheter had to be inserted postoperatively for urine retention and/or monitoring of fluid balance and who were divided into two groups on a rota basis. No antibiotics were administered to the first group, whereas Cotrimoxazol 960 mg tablets p.o. was administered to the second group, 14 and 2 hours before the removal of the catheter. The urine culture test was performed 4 hours after the removal of the indwelling urinary catheter, in both the groups. The test was repeated after 14 days and a questionnaire was filled in to report urinary tract complications. Considered as significant bacteriuria by urinalysis was the laboratory finding of > 10x4 CFU/ml in case of a single pathogen or > 10x5 in case of multiple pathogens. The results were statistically processed by Fischer's exact test with the level of significance = 0.05. RESULTS In the first part of the study leukocyturia was detected by a test strip in 112 of the total of 478 patients. In 10 women, significant bacteriuria was found. Altogether 50 women and 50 men were randomly assigned to the second part of the study. The indwelling urinary catheter was in place for 4 days on average. In men, no statistically significant difference was detected in significant bacteriuria findings, in women a statistically significant difference of p = 0.00162 was found after the removal and after 14 days the borderline of statistical significance of p = 0.0507 was achieved, but no symptomatic urinary tract infection was present. In the period from 20 to 32 months following the total joint replacement, no periprosthetic infection caused by urinary tract infection was reported. DISCUSSION There is enough evidence to prove the correlation between the symptomatic urinary tract infection and periprosthetic infection. On the other hand, asymptomatic bacteriuria is a common finding in patients before the planned hip of knee joint replacement and its treatment is not recommended. No consensus has been achieved as yet regarding the method of antibiotic prophylaxis for an inserted urinary catheter. Antibiotics are administered throughout the period of catheterisation by an indwelling urinary catheter, during its removal, or are not administered at all. In our study antibiotics were administered during the removal of an indwelling urinary catheter and a statistically significant difference was found in women. It concerned, however, only a higher incidence of asymptomatic bacteriuria not treated by antibiotics, which in the next follow-up period did not lead to periprosthetic infection. CONCLUSIONS Despite the negative pre-operative urine culture, frequent incidence of leukocyturia and symptomatic urinary infections were detected in a fairly high number of cases. Therefore, we recommend asking the patients during the hospital admission process specifically about the urinary infection symptoms. The results of our study show that antibiotic prophylaxis during the removal of indwelling urinary catheters placed for a short-term is unnecessary. Key words: endoprosthesis, urinary catheter, bacteriuria, urinary tract infection.
Sidiras, Chris; Iliadou, Vasiliki Vivian; Chermak, Gail D; Nimatoudis, Ioannis
2016-05-01
Including speech recognition in noise testing in audiological evaluations may reveal functional hearing deficits that may otherwise remain undetected. The current study explored the potential utility of the Speech-in-Babble (SinB) test in the assessment of central auditory processing disorder (CAPD) in young children for whom diagnosis is challenging. A cross-sectional analysis. Forty-one Greek children 4-13 yr of age diagnosed with CAPD and exhibiting listening and academic problems (clinical group) and 20 age-matched controls with no listening or academic problems participated in the study. All participants' auditory processing was assessed using the same tests and instrumentation in a sound-treated room. Two equivalent lists of the SinB test, developed at the Psychoacoustic Laboratory of the Aristotle University of Thessaloniki, were administered monaurally in a counterbalanced order. SinB consists of lists of 50 phonetically balanced disyllabic words presented in background multitalker babble. Five signal-to-noise ratios (SNRs) were used in a fixed order. The children were instructed to repeat the word after each presentation. The SNR at which the child achieved 50% correct word identification served as the dependent variable or outcome measure, with higher SinB scores (measured in SNR dB) corresponding to poorer performance. SinB performance was better (lower SNR) for the normal control group versus the clinical group [F(1,35) = 43.03, p < 0.0001]. SinB inversely correlated with age for both CAPD and control groups (r = -0.648, p < 0.001 and r = -0.658, p < 0.005, respectively). Regression analysis revealed that linear models better explained the variance in the data than a quadratic model for both the control and CAPD groups. The slope (beta value of the linear model) was steeper for the clinical group compared to the control group (beta = -0.306 versus beta = -0.130, respectively). An analysis of covariance run with age as the covariate to assess the potential effect of comorbidity on SinB performance in children with CAPD with and without comorbid conditions revealed no significant differences between groups [F(1,38) = 0.149, p > 0.05]. This study offers the first detailed presentation of the performance of Greek children on a Greek language SinB test. The main finding is that SinB scores improved as a function of age in a constant manner as represented by the slope of the linear regression line for both CAPD and control groups. Results suggest that this speech recognition in competition test holds promise for differentiating typically developing Greek children from those children with CAPD across the age range studied here (4-13 yr). The SinB seemed rather immune to the presence of comorbid conditions presented by some of the children in this study, suggesting its potential utility as a valid measure of central auditory processing. While there are many speech-in-noise or competition tests in English, there are fewer in other languages. Tests like the SinB should be developed in other languages to ensure that children demonstrating "listening" problems can be properly evaluated. American Academy of Audiology.
Manjila, Sunil; Karhade, Aditya; Phi, Ji Hoon; Scott, R Michael; Smith, Edward R
2017-01-01
Brain shift during the exposure of cranial lesions may reduce the accuracy of frameless stereotaxy. We describe a rapid, safe, and effective method to approach deep-seated brain lesions using real-time intraoperative ultrasound placement of a catheter to mark the dissection trajectory to the lesion. With Institutional Review Board approval, we retrospectively reviewed the radiographic, pathologic, and intraoperative data of 11 pediatric patients who underwent excision of 12 lesions by means of this technique. Full data sets were available for 12 lesions in 11 patients. Ten lesions were tumors and 2 were cavernous malformations. Lesion locations included the thalamus (n = 4), trigone (n = 3), mesial temporal lobe (n = 3), and deep white matter (n = 2). Catheter placement was successful in all patients, and the median time required for the procedure was 3 min (range 2-5 min). There were no complications related to catheter placement. The median diameter of surgical corridors on postresection magnetic resonance imaging was 6.6 mm (range 3.0-12.1 mm). Use of real-time ultrasound guidance to place a catheter to aid in the dissection to reach a deep-seated brain lesion provides advantages complementary to existing techniques, such as frameless stereotaxy. The catheter insertion technique described here provides a quick, accurate, and safe method for reaching deep-seated lesions. © 2017 S. Karger AG, Basel.