Sample records for capillary electrophoretic analysis

  1. Principles of Micellar Electrokinetic Capillary Chromatography Applied in Pharmaceutical Analysis

    PubMed Central

    Hancu, Gabriel; Simon, Brigitta; Rusu, Aura; Mircia, Eleonora; Gyéresi, Árpád

    2013-01-01

    Since its introduction capillary electrophoresis has shown great potential in areas where electrophoretic techniques have rarely been used before, including here the analysis of pharmaceutical substances. The large majority of pharmaceutical substances are neutral from electrophoretic point of view, consequently separations by the classic capillary zone electrophoresis; where separation is based on the differences between the own electrophoretic mobilities of the analytes; are hard to achieve. Micellar electrokinetic capillary chromatography, a hybrid method that combines chromatographic and electrophoretic separation principles, extends the applicability of capillary electrophoretic methods to neutral analytes. In micellar electrokinetic capillary chromatography, surfactants are added to the buffer solution in concentration above their critical micellar concentrations, consequently micelles are formed; micelles that undergo electrophoretic migration like any other charged particle. The separation is based on the differential partitioning of an analyte between the two-phase system: the mobile aqueous phase and micellar pseudostationary phase. The present paper aims to summarize the basic aspects regarding separation principles and practical applications of micellar electrokinetic capillary chromatography, with particular attention to those relevant in pharmaceutical analysis. PMID:24312804

  2. Fast electrophoretic analysis of individual mitochondria using microchip capillary electrophoresis with laser induced fluorescence detection.

    PubMed

    Duffy, Ciarán F; MacCraith, Brian; Diamond, Dermot; O'Kennedy, Richard; Arriaga, Edgar A

    2006-08-01

    The analysis of mitochondria by capillary electrophoresis usually takes longer than 20 min per replicate which may compromise the quality of the mitochondria due to degradation. In addition, low sample consumption may be beneficial in the analysis of rare or difficult samples. In this report, we demonstrate the ability to analyze individual mitochondrial events in picoliter-volume samples (approximately 80 pL) taken from a bovine liver preparation using microchip capillary electrophoresis with laser-induced fluorescence detection (micro-chip CE-LIF). Using a commercial "double-T" glass microchip, the sample was electrokinetically loaded in the "double-T" intersection and then subjected to electrophoretic separation along the main separation channel. In order to decrease interactions of mitochondria with channel walls during the analysis, poly(vinyl alcohol) was used as a dynamic coating. This procedure eliminates the need for complicated covalent surface modifications within the channels that were previously used in capillary electrophoresis methods. For analysis, mitochondria, isolated from bovine liver tissue, were selectively labelled using 10-nonyl acridine orange (NAO). The results consist of electropherograms where each mitochondrial event is a narrow spike (240 +/- 44 ms). While the spike intensity is representative of its NAO content, its migration time is used to calculate and describe its electrophoretic mobility, which is a property still largely unexplored for intracellular organelles. The five-fold decrease in separation time (4 min for microchip versus 20 min for capillary electrophoresis) makes microchip electrophoretic separations of organelles a faster, sensitive, low-sample volume alternative for the characterization of individual organelle properties and for investigations of subcellular heterogeneity.

  3. CAPILLARY ELECTROPHORETIC BEHAVIOR OF SEVEN SULFONYLUREAS

    EPA Science Inventory

    The electrophoretic behavior of bensulfuron Me, sulfometuron Me, nicosulfuron (Accent), chlorimuron Et, thifensulfuron Me (Harmony), metsulfuron Me, and chlorsulfuron was studied under capillary zone electrophoresis (CZE) and micellar electrokinetic chromatography (MEKC) conditio...

  4. Fingerprinting postblast explosive residues by portable capillary electrophoresis with contactless conductivity detection.

    PubMed

    Kobrin, Eeva-Gerda; Lees, Heidi; Fomitšenko, Maria; Kubáň, Petr; Kaljurand, Mihkel

    2014-04-01

    A portable capillary electrophoretic system with contactless conductivity detection was used for fingerprint analysis of postblast explosive residues from commercial organic and improvised inorganic explosives on various surfaces (sand, concrete, metal witness plates). Simple extraction methods were developed for each of the surfaces for subsequent simultaneous capillary electrophoretic analysis of anions and cations. Dual-opposite end injection principle was used for fast (<4 min) separation of 10 common anions and cations from postblast residues using an optimized separation electrolyte composed of 20 mM MES, 20 mM l-histidine, 30 μM CTAB and 2 mM 18-crown-6. The concentrations of all ions obtained from the electropherograms were subjected to principal component analysis to classify the tested explosives on all tested surfaces, resulting in distinct cluster formations that could be used to verify (each) type of the explosive. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. INFLUENCE OF BORATE BUFFERS ON THE ELECTROPHORETIC BEHAVIOR OF HUMIC SUBSTANCES IN CAPILLARY ZONE ELECTROPHORESIS

    EPA Science Inventory

    The influence of tetrahydroxyborate ions on the electrophoretic mobility of humic acids was evaluated by capillary electrophoresis (CE). Depending on the molarity of borate ions in the separation buffer, the humic acids exhibit electropherograms with sharp peaks consistently exte...

  6. Biochemical analysis with microfluidic systems.

    PubMed

    Bilitewski, Ursula; Genrich, Meike; Kadow, Sabine; Mersal, Gaber

    2003-10-01

    Microfluidic systems are capillary networks of varying complexity fabricated originally in silicon, but nowadays in glass and polymeric substrates. Flow of liquid is mainly controlled by use of electroosmotic effects, i.e. application of electric fields, in addition to pressurized flow, i.e. application of pressure or vacuum. Because electroosmotic flow rates depend on the charge densities on the walls of capillaries, they are influenced by substrate material, fabrication processes, surface pretreatment procedures, and buffer additives. Microfluidic systems combine the properties of capillary electrophoretic systems and flow-through analytical systems, and thus biochemical analytical assays have been developed utilizing and integrating both aspects. Proteins, peptides, and nucleic acids can be separated because of their different electrophoretic mobility; detection is achieved with fluorescence detectors. For protein analysis, in particular, interfaces between microfluidic chips and mass spectrometers were developed. Further levels of integration of required sample-treatment steps were achieved by integration of protein digestion by immobilized trypsin and amplification of nucleic acids by the polymerase chain reaction. Kinetic constants of enzyme reactions were determined by adjusting different degrees of dilution of enzyme substrates or inhibitors within a single chip utilizing mainly the properties of controlled dosing and mixing liquids within a chip. For analysis of kinase reactions, however, a combination of a reaction step (enzyme with substrate and inhibitor) and a separation step (enzyme substrate and reaction product) was required. Microfluidic chips also enable separation of analytes from sample matrix constituents, which can interfere with quantitative determination, if they have different electrophoretic mobilities. In addition to analysis of nucleic acids and enzymes, immunoassays are the third group of analytical assays performed in microfluidic chips. They utilize either affinity capillary electrophoresis as a homogeneous assay format, or immobilized antigens or antibodies in heterogeneous assays with serial supply of reagents and washing solutions.

  7. The use of experimental design for the development of a capillary zone electrophoresis method for the quantitation of captopril.

    PubMed

    Mukozhiwa, S Y; Khamanga, S M M; Walker, R B

    2017-09-01

    A capillary zone electrophoresis (CZE) method for the quantitation of captopril (CPT) using UV detection was developed. Influence of electrolyte concentration and system variables on electrophoretic separation was evaluated and a central composite design (CCD) was used to optimize the method. Variables investigated were pH, molarity, applied voltage and capillary length. The influence of sodium metabisulphite on the stability of test solutions was also investigated. The use of sodium metabisulphite prevented degradation of CPT over 24 hours. A fused uncoated silica capillary of 67.5cm total and 57.5 cm effective length was used for analysis. The applied voltage and capillary length affected the migration time of CPT significantly. A 20 mM phosphate buffer adjusted to pH 7.0 was used as running buffer and an applied voltage of 23.90 kV was suitable to effect a separation. The optimized electrophoretic conditions produced sharp, well-resolved peaks for CPT and sodium metabisulphite. Linear regression analysis of the response for CPT standards revealed the method was linear (R2 = 0.9995) over the range 5-70 μg/mL. The limits of quantitation and detection were 5 and 1.5 μg/mL. A simple, rapid and reliable CZE method has been developed and successfully applied to the analysis of commercially available CPT products.

  8. Comprehensive and Critical Literature Review on Insitu Micro-Sensors for Application in Tribology

    DTIC Science & Technology

    1994-04-01

    Electroosmotic flow provides a pumping method that is convenient for small capillaries. Electrophoretic separation is shown to be useful. On the left hand...analysis systems on glass chips (1 centimeter by 2 centimeters or larger) that utilize electroosmotic pumping to drive fluid flow and electrophoretic...elucidate the interaction mechanism. Additionally, using two types of sensors in a mixed array increases selectivity by providing different information

  9. Assessment of the capillary zone electrophoretic behavior of proteins in the presence of electroosmotic modifiers: protein-polyamine interaction studied using a polyacrylamide-coated capillary.

    PubMed

    Kubo, K; Hattori, A

    2001-10-01

    The use of polyamines as electroosmotic modifiers has been shown to be effective in enhancing resolution of protein glycoforms in capillary zone electrophoresis (CZE) using a bare capillary tube. In this study, effectiveness was evaluated by using a polyacrylamide-coated capillary tube instead of a bare capillary tube. Electropherograms obtained in the presence of polyamines were inferior to those obtained in their absence with respect to resolution. Electrophoretic mobility of the proteins decreased and their peaks were broadened by polyamines bound to them. This unfavorable effect was dependent on both the species of polyamines and the pH values of the electrolyte buffer. The reduction of resolution caused by polyamines was in the following order: spermidine (SPD) approximately spermidine-tri-hydrochloride (SPD-HCI) > putrescine (PUT) > hexamethonium chloride (HMC). The observed effect can be ascribed to the formation of complexes between the proteins and the polyamines. In addition, for the bare capillary tube the complexes showed interaction with the inner surface, resulting in local suppression of electroosmosis and poor resolution. The high resolution obtained in the coated capillary tube was reduced in the presence of the polyamines. Thus, the use of the polyamines has a negative effect on the analysis of protein microheterogeneity as a result of protein-polyamine interaction.

  10. The interface of an array of five capillaries with an array of one-nanoliter wells for high-resolution electrophoretic analysis as an approach to high-throughput chemical cytometry

    PubMed Central

    Boardman, Anna; McQuaide, Sarah C.; Zhu, Cuiru; Whitmore, Colin; Lidstrom, Mary E.; Dovichi, Norman J.

    2009-01-01

    We report a system that allows the simultaneous aspiration of one or more cells into each of five capillaries for electrophoresis analysis. A glass wafer was etched to create an array of 1 nL wells. The glass was treated with poly(2-hydroxyethyl methacrylate) to control cell adherence. A suspension of formalin-fixed cells was placed on the surface, and cells were allowed to settle. The concentration of cells and the settling time were chosen so that there was, on average, one cell per well. Next, an array of five capillaries was placed so that the tip of each capillary was in contact with a single well. A pulse of vacuum was applied to the distal end of the capillaries to aspirate the content of each well into a capillary. Next, the tips of the capillaries were placed in running buffer and potential was applied. The cells lysed upon contact with the running buffer, and fluorescent components were detected at the distal end of the capillaries by laser-induced fluorescence. The electrophoretic separation efficiency was outstanding, generating over 750,000 theoretical plates (1,800,000 plates/meter). In this example, AtT-20 cells were used that had been treated with TMR-GM1. The cells were allowed to metabolize this substrate into a series of products before the cells were fixed. The number of cells found in each well was estimated visually under the microscope and was described by a Poisson distribution with mean of 0.95 cells/well. This system provides an approach to high-throughput chemical cytometry. PMID:18717573

  11. Hydrodynamic sample injection into short electrophoretic capillary in systems with a flow-gating interface.

    PubMed

    Opekar, František; Tůma, Petr

    2017-01-13

    An electrophoretic apparatus with a flow-gating interface has been developed, enabling hydrodynamic sequence injection of the sample into the separation capillary from the liquid flow by underpressure generated in the outlet electrophoretic vessel. The properties of the apparatus were tested on an artificial sample of an equimolar mixture of 100μM potassium and sodium ions and arginine. The repeatability of the injection of the tested ions expressed as RSD (in%) for the peak area, peak height and migration time was in the range 0.76-2.08, 0.18-0.68 and 0.28-0.48, respectively. Under optimum conditions, the apparatus was used for sequence monitoring of the reaction between the antidiabetic drug phenyl biguanide and the glycation agent methyl glyoxal. The reaction solution was continuously sampled by a microdialysis probe from a thermostated external vessel using a syringe pump at a flow rate of 3μLmin -1 and was injected into a separation capillary at certain time intervals. The electrophoretic separation progressed in a capillary with an internal diameter of 50μm with a length of 11.5cm and was monitored using a contactless conductivity detector. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. An integrated passive micromixer-magnetic separation-capillary electrophoresis microdevice for rapid and multiplex pathogen detection at the single-cell level.

    PubMed

    Jung, Jae Hwan; Kim, Gha-Young; Seo, Tae Seok

    2011-10-21

    Here we report an integrated microdevice consisting of an efficient passive mixer, a magnetic separation chamber, and a capillary electrophoretic microchannel in which DNA barcode assay, target pathogen separation, and barcode DNA capillary electrophoretic analysis were performed sequentially within 30 min for multiplex pathogen detection at the single-cell level. The intestine-shaped serpentine 3D micromixer provides a high mixing rate to generate magnetic particle-pathogenic bacteria-DNA barcode labelled AuNP complexes quantitatively. After magnetic separation and purification of those complexes, the barcode DNA strands were released and analyzed by the microfluidic capillary electrophoresis within 5 min. The size of the barcode DNA strand was controlled depending on the target bacteria (Staphylococcus aureus, Escherichia coli O157:H7, and Salmonella typhimurium), and the different elution time of the barcode DNA peak in the electropherogram allows us to recognize the target pathogen with ease in the monoplex as well as in the multiplex analysis. In addition, the quantity of the DNA barcode strand (∼10(4)) per AuNP is enough to be observed in the laser-induced confocal fluorescence detector, thereby making single-cell analysis possible. This novel integrated microdevice enables us to perform rapid, sensitive, and multiplex pathogen detection with sample-in-answer-out capability to be applied for biosafety testing, environmental screening, and clinical trials.

  13. Nitrate and Nitrite Determination in Gunshot Residue Samples by Capillary Electrophoresis in Acidic Run Buffer.

    PubMed

    Erol, Özge Ö; Erdoğan, Behice Y; Onar, Atiye N

    2017-03-01

    Simultaneous determination of nitrate and nitrite in gunshot residue has been conducted by capillary electrophoresis using an acidic run buffer (pH 3.5). In previously developed capillary electrophoretic methods, alkaline pH separation buffers were used where nitrite and nitrate possess similar electrophoretic mobility. In this study, the electroosmotic flow has been reversed by using low pH running buffer without any additives. As a result of reversing the electroosmotic flow, very fast analysis has been actualized, well-defined and separated ion peaks emerge in less than 4 min. Besides, the limit of detection was improved by employing large volume sample stacking. Limit of detection values were 6.7 and 4.3 μM for nitrate and nitrite, respectively. In traditional procedure, mechanical agitation is employed for extraction, while in this work the extraction efficiency of ultrasound mixing for 30 min was found sufficient. The proposed method was successfully applied to authentic gunshot residue samples. © 2016 American Academy of Forensic Sciences.

  14. Affinity monolith-integrated poly(methyl methacrylate) microchips for on-line protein extraction and capillary electrophoresis.

    PubMed

    Sun, Xiuhua; Yang, Weichun; Pan, Tao; Woolley, Adam T

    2008-07-01

    Immunoaffinity monolith pretreatment columns have been coupled with capillary electrophoresis separation in poly(methyl methacrylate) (PMMA) microchips. Microdevices were designed with eight reservoirs to enable the electrically controlled transport of selected analytes and solutions to carry out integrated immunoaffinity extraction and electrophoretic separation. The PMMA microdevices were fabricated reproducibly and with high fidelity by solvent imprinting and thermal bonding methods. Monoliths with epoxy groups for antibody immobilization were prepared by direct in situ photopolymerization of glycidyl methacrylate and ethylene glycol dimethacrylate in a porogenic solvent consisting of 70% 1-dodecanol and 30% cyclohexanol. Antifluorescein isothiocyanate was utilized as a model affinity group in the monoliths, and the immobilization process was optimized. A mean elution efficiency of 92% was achieved for the monolith-based extraction of fluorescein isothiocyanate (FITC)-tagged human serum albumin. FITC-tagged proteins were purified from a contaminant protein and then separated electrophoretically using these devices. The developed immunoaffinity column/capillary electrophoresis microdevices show great promise for combining sample pretreatment and separation in biomolecular analysis.

  15. Affinity Monolith-Integrated Poly(methyl Methacrylate) Microchips for On-Line Protein Extraction and Capillary Electrophoresis

    PubMed Central

    Sun, Xiuhua; Yang, Weichun; Pan, Tao; Woolley, Adam T.

    2008-01-01

    Immunoaffinity monolith pretreatment columns have been coupled with capillary electrophoresis separation in poly(methyl methacrylate) (PMMA) microchips. Microdevices were designed with 8 reservoirs to enable the electrically controlled transport of selected analytes and solutions to carry out integrated immunoaffinity extraction and electrophoretic separation. The PMMA microdevices were fabricated reproducibly and with high fidelity by solvent imprinting and thermal bonding methods. Monoliths with epoxy groups for antibody immobilization were prepared by direct in-situ photopolymerization of glycidyl methacrylate and ethylene dimethacrylate in a porogenic solvent consisting of 70% dodecanol and 30% hexanol. Anti-fluorescein isothiocyanate (FITC) was utilized as a model affinity group in the monoliths, and the immobilization process was optimized. A mean elution efficiency of 92% was achieved for the monolith-based extraction of FITC-tagged human serum albumin. FITC-tagged proteins were purified from a contaminant protein and then separated electrophoretically using these devices. The developed immunoaffinity column/capillary electrophoresis microdevices show great promise for combining sample pretreatment and separation in biomolecular analysis. PMID:18479142

  16. Atomic-force-controlled capillary electrophoretic nanoprinting of proteins.

    PubMed

    Lovsky, Yulia; Lewis, Aaron; Sukenik, Chaim; Grushka, Eli

    2010-01-01

    The general nanoprinting and nanoinjection of proteins on non-conducting or conducting substrates with a high degree of control both in terms of positional and timing accuracy is an important goal that could impact diverse fields from biotechnology (protein chips) to molecular electronics and from fundamental studies in cell biology to nanophotonics. In this paper, we combine capillary electrophoresis (CE), a separation method with considerable control of protein movement, with the unparalleled positional accuracy of an atomic force microscope (AFM). This combination provides the ability to electrophoretically or electroosmotically correlate the timing of protein migration with AFM control of the protein deposition at a high concentration in defined locations and highly confined volumes estimated to be 2 al. Electrical control of bovine serum albumin printing on standard protein-spotting glass substrates is demonstrated. For this advance, fountain pen nanolithography (FPN) that uses cantilevered glass-tapered capillaries is amended with the placement of electrodes on the nanopipette itself. This results in imposed voltages that are three orders of magnitude less than what is normally used in capillary electrophoresis. The development of atomic-force-controlled capillary electrophoretic printing (ACCEP) has the potential for electrophoretic separation, with high resolution, both in time and in space. The large voltage drop at the tip of the tapered nanopipettes allows for significant increases in concentration of protein in the small printed volumes. All of these attributes combine to suggest that this methodology should have a significant impact in science and technology.

  17. Strategies for the capillary electrophoretic separation of indole alkaloids in Psilocybe semilanceata.

    PubMed

    Pedersen-Bjergaard, S; Rasmussen, K E; Sannes, E

    1998-01-01

    While the hallucinogenic mushrooms Psilocybe semilanceata have previously been analyzed for the indole alkaloids psilocybin and baeocystin by capillary zone electrophoresis (CZE) at pH 11.5, the present work focused on the development of an alternative and complementary capillary electrophoretic method for their identification. Owing to their structural similarity and zwitterionic nature, the compounds were difficult to resolve based on different interactions with cationic or anionic micelles. However, while the attempts with micellar electrokinetic chromatography (MEKC) were unsuccessful, rapid derivatization with propyl chloroformate and reanalysis by CZE at pH 11.5 was effective to support identification of the two indole alkaloids. Psilocin was difficult to analyze by CZE at pH 11.5 owing to comigration with the electroosmotic flow. For this compound, the pH of the running buffer was reduced to 7.2 to effectively enhance the electrophoretic mobility.

  18. Enhanced Microchip Electrophoresis Separations Combined with Electrochemical Detection Utilizing a Capillary Embedded in Polystyrene.

    PubMed

    Mehl, Benjamin T; Martin, R Scott

    2018-01-07

    The ability to use microchip-based electrophoresis for fast, high-throughput separations provides researchers with a tool for close-to real time analysis of biological systems. While PDMS-based electrophoresis devices are popular, the separation efficiency is often an issue due to the hydrophobic nature of PDMS. In this study, a hybrid microfluidic capillary device was fabricated to utilize the positive features of PDMS along with the electrophoretic performance of fused silica. A capillary loop was embedded in a polystyrene base that can be coupled with PDMS microchannels at minimal dead volume interconnects. A method for cleaning out the capillaries after a wet-polishing step was devised through the use of 3D printed syringe attachment. By comparing the separation efficiency of fluorescein and CBI-glycine with both a PDMS-based serpentine device and the embedded capillary loop device, it was shown that the embedded capillary loop device maintained higher theoretical plates for both analytes. A Pd decoupler with a carbon or Pt detection electrode were embedded along with the loop allowing integration of the electrophoretic separation with electrochemical detection. A series of catecholamines were separated to show the ability to resolve similar analytes and detect redox active species. The release of dopamine and norepinephrine from PC 12 cells was also analyzed showing the compatibility of these improved microchip separations with high ionic cell buffers associated with cell culture.

  19. Automated Parallel Capillary Electrophoretic System

    DOEpatents

    Li, Qingbo; Kane, Thomas E.; Liu, Changsheng; Sonnenschein, Bernard; Sharer, Michael V.; Kernan, John R.

    2000-02-22

    An automated electrophoretic system is disclosed. The system employs a capillary cartridge having a plurality of capillary tubes. The cartridge has a first array of capillary ends projecting from one side of a plate. The first array of capillary ends are spaced apart in substantially the same manner as the wells of a microtitre tray of standard size. This allows one to simultaneously perform capillary electrophoresis on samples present in each of the wells of the tray. The system includes a stacked, dual carousel arrangement to eliminate cross-contamination resulting from reuse of the same buffer tray on consecutive executions from electrophoresis. The system also has a gel delivery module containing a gel syringe/a stepper motor or a high pressure chamber with a pump to quickly and uniformly deliver gel through the capillary tubes. The system further includes a multi-wavelength beam generator to generate a laser beam which produces a beam with a wide range of wavelengths. An off-line capillary reconditioner thoroughly cleans a capillary cartridge to enable simultaneous execution of electrophoresis with another capillary cartridge. The streamlined nature of the off-line capillary reconditioner offers the advantage of increased system throughput with a minimal increase in system cost.

  20. Fluid Delivery System For Capillary Electrophoretic Applications.

    DOEpatents

    Li, Qingbo; Liu, Changsheng; Kane, Thomas E.; Kernan, John R.; Sonnenschein, Bernard; Sharer, Michael V.

    2002-04-23

    An automated electrophoretic system is disclosed. The system employs a capillary cartridge having a plurality of capillary tubes. The cartridge has a first array of capillary ends projecting from one side of a plate. The first array of capillary ends are spaced apart in substantially the same manner as the wells of a microtitre tray of standard size. This allows one to simultaneously perform capillary electrophoresis on samples present in each of the wells of the tray. The system includes a stacked, dual carrousel arrangement to eliminate cross-contamination resulting from reuse of the same buffer tray on consecutive executions from electrophoresis. The system also has a gel delivery module containing a gel syringe/a stepper motor or a high pressure chamber with a pump to quickly and uniformly deliver gel through the capillary tubes. The system further includes a multi-wavelength beam generator to generate a laser beam which produces a beam with a wide range of wavelengths. An off-line capillary reconditioner thoroughly cleans a capillary cartridge to enable simultaneous execution of electrophoresis with another capillary cartridge. The streamlined nature of the off-line capillary reconditioner offers the advantage of increased system throughput with a minimal increase in system cost.

  1. Electrophoretic analysis of biomarkers using capillary modification with gold nanoparticles embedded in a polycation and boron doped diamond electrode.

    PubMed

    Zhou, Lin; Glennon, Jeremy D; Luong, John H T

    2010-08-15

    Field-amplified sample stacking using a fused silica capillary coated with gold nanoparticles (AuNPs) embedded in poly(diallyl dimethylammonium) chloride (PDDA) has been investigated for the electrophoretic separation of indoxyl sulfate, homovanillic acid (HVA), and vanillylmandelic acid (VMA). AuNPs (27 nm) exhibit ionic and hydrophobic interactions, as well as hydrogen bonding with the PDDA network to form a stable layer on the internal wall of the capillary. This approach reverses electro-osmotic flow allowing for fast migration of the analytes while retarding other endogenous compounds including ascorbic acid, uric acid, catecholamines, and indoleamines. Notably, the two closely related biomarkers of clinical significance, HVA and VMA, displayed differential interaction with PDDA-AuNPs which enabled the separation of this pair. The detection limit of the three analytes obtained by using a boron doped diamond electrode was approximately 75 nM, which was significantly below their normal physiological levels in biological fluids. This combined separation and detection scheme was applied to the direct analysis of these analytes and other interfering chemicals including uric and ascorbic acids in urine samples without off-line sample treatment or preconcentration.

  2. Effect of surfactant species and electrophoretic medium composition on the electrophoretic behavior of neutral and water-insoluble linear synthetic polymers in nonaqueous capillary zone electrophoresis.

    PubMed

    Fukai, Nao; Kitagawa, Shinya; Ohtani, Hajime

    2017-07-01

    We have recently demonstrated the separation of neutral and water-insoluble linear synthetic polymers in nonaqueous capillary zone electrophoresis (NACZE) using a cationic surfactant of cetyltrimethylammonium chloride (CTAC). In this study, eight ionic surfactants were investigated for the separation of four synthetic polymers (polystyrene, polymethylmethacrylates, polybutadiene, and polycarbonate); only three surfactants (CTAC, dimethyldioctadecylammonium bromide, and sodium dodecylsulfate) caused their separation. The order of the interaction between the polymers and the surfactants depended on both the surfactant species and the composition of the electrophoretic medium. Their investigation revealed that the separation is majorly affected by the hydrophobic interactions between the polymers and the ionic surfactants. In addition, the electrophoretic behavior of polycarbonate suggested that electrostatic interaction also affects the selectivity of the polymers. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Design and operation of a portable scanner for high performance microchip capillary array electrophoresis.

    PubMed

    Scherer, James R; Liu, Peng; Mathies, Richard A

    2010-11-01

    We have developed a compact, laser-induced fluorescence detection scanner, the multichannel capillary array electrophoresis portable scanner (McCAEPs) as a platform for electrophoretic detection and control of high-throughput, integrated microfluidic devices for genetic and other analyses. The instrument contains a confocal optical system with a rotary objective for detecting four different fluorescence signals, a pneumatic system consisting of two pressure/vacuum pumps and 28 individual addressable solenoid valves for control of on-chip microvalves and micropumps, four Polymerase Chain Reaction (PCR) temperature control systems, and four high voltage power supplies for electrophoresis. The detection limit of the instrument is ~20 pM for on-chip capillary electrophoresis of fluorescein dyes. To demonstrate the system performance for forensic short tandem repeat (STR) analysis, two experiments were conducted: (i) electrophoretic separation and detection of STR samples on a 96-lane microfabricated capillary array electrophoresis microchip. Fully resolved PowerPlex(®) 16 STR profiles amplified from 1 ng of 9947A female standard DNA were successfully obtained; (ii) nine-plex STR amplification, sample injection, separation, and fluorescence detection of 100-copy 9948 male standard DNA in a single integrated PCR- capillary electrophoresis microchip. These results demonstrate that the McCAEPs can be used as a versatile control and detection instrument that operates integrated microfluidic devices for high-performance forensic human identification.

  4. Design and operation of a portable scanner for high performance microchip capillary array electrophoresis

    NASA Astrophysics Data System (ADS)

    Scherer, James R.; Liu, Peng; Mathies, Richard A.

    2010-11-01

    We have developed a compact, laser-induced fluorescence detection scanner, the multichannel capillary array electrophoresis portable scanner (McCAEPs) as a platform for electrophoretic detection and control of high-throughput, integrated microfluidic devices for genetic and other analyses. The instrument contains a confocal optical system with a rotary objective for detecting four different fluorescence signals, a pneumatic system consisting of two pressure/vacuum pumps and 28 individual addressable solenoid valves for control of on-chip microvalves and micropumps, four Polymerase Chain Reaction (PCR) temperature control systems, and four high voltage power supplies for electrophoresis. The detection limit of the instrument is ˜20 pM for on-chip capillary electrophoresis of fluorescein dyes. To demonstrate the system performance for forensic short tandem repeat (STR) analysis, two experiments were conducted: (i) electrophoretic separation and detection of STR samples on a 96-lane microfabricated capillary array electrophoresis microchip. Fully resolved PowerPlex® 16 STR profiles amplified from 1 ng of 9947A female standard DNA were successfully obtained; (ii) nine-plex STR amplification, sample injection, separation, and fluorescence detection of 100-copy 9948 male standard DNA in a single integrated PCR- capillary electrophoresis microchip. These results demonstrate that the McCAEPs can be used as a versatile control and detection instrument that operates integrated microfluidic devices for high-performance forensic human identification.

  5. Electrophoretically mediated microanalysis of a nicotinamide adenine dinucleotide-dependent enzyme and its facile multiplexing using an active pixel sensor UV detector.

    PubMed

    Urban, Pawel L; Goodall, David M; Bergström, Edmund T; Bruce, Neil C

    2007-08-31

    An electrophoretically mediated microanalysis (EMMA) method has been developed for yeast alcohol dehydrogenase and quantification of reactant and product cofactors, NAD and NADH. The enzyme substrate ethanol (1% (v/v)) was added to the buffer (50 mM borate, pH 8.8). Results are presented for parallel capillary electrophoresis with a novel miniature UV area detector, with an active pixel sensor imaging an array of two or six parallel capillaries connected via a manifold to a single output capillary in a commercial CE instrument, allowing conversions with five different yeast alcohol dehydrogenase concentrations to be quantified in a single experiment.

  6. Influence of somatic cell count and breed on capillary electrophoretic protein profiles of ewes' milk: a chemometric study.

    PubMed

    Rodríguez-Nogales, J M; Vivar-Quintana, A M; Revilla, I

    2007-07-01

    Bulk tank ewe milk from the Assaf, Castellana, and Churra breeds categorized into 3 somatic cell count (SCC) groups (<500,000; 1,000,000 to 1,500,000; and >2,500,000 cells/mL) was used to investigate changes in chemical composition and capillary electrophoresis protein profiles. The results obtained indicated that breed affected fat, protein, and total solids levels, and differences were also observed for the following milk proteins: beta-, beta1-, beta2-, and alpha(s1)-III-casein, alpha-lactalbumin, and beta-lactoglobulin. High SCC affected fat and protein contents and bacterial counts. The level of beta1-, beta2-, and alpha(s1)-I-casein, and alpha-lactalbumin were significantly lower in milk with SCC scores >2,500,000 cells/mL. A preliminary study of the chemical, microbiological, and electrophoretic data was performed by cluster analysis and principal components analysis. Applying discriminant analysis, it was possible to group the milk samples according to breed and level of SCC, obtaining a prediction of 100 and 97% of the samples, respectively.

  7. Contribution of capillary electrophoresis to an integrated vision of humic substances size and charge characterizations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D'Orlye, Fanny; Reiller, Pascal E.

    2014-02-15

    The physicochemical properties of three different humic substances (HS) are probed using capillary zone electrophoresis in alkaline carbonate buffers, pH 10. Special attention is drawn to the impact of the electrolyte ionic strength and counter-ion nature, chosen within the alkali-metal series, on HS electrophoretic mobility. Taylor-Aris dispersion analysis provides insights into the hydrodynamic radius (R-H) distributions of HS. The smallest characterized entities are of nano-metric dimensions, showing neither ionic strength- nor alkali-metal-induced aggregation. These results are compared with the entities evidenced in dynamic light scattering measurements, the size of which is two order of magnitude higher, ca. 100 nm. Themore » extended Onsager model provides a reasonable description of measured electrophoretic mobilities in the ionic strength range 1-50 mM, thus allowing the estimation of limiting mobilities and ionic charge numbers for the different HS samples. An unexpected HS electrophoretic mobility increase (in absolute value) is observed in the order Li{sup +} ≤ Na{sup +} ≤ K{sup +} ≤ Cs{sup +} and discussed either in terms of retarding forces or in terms of ion-ion interactions. (authors)« less

  8. Influence of Analyte Concentration on Stability Constant Values Determined by Capillary Electrophoresis.

    PubMed

    Sursyakova, Viktoria V; Burmakina, Galina V; Rubaylo, Anatoly I

    2016-08-01

    The influence of analyte concentration when compared with the concentration of a charged ligand in background electrolyte (BGE) on the measured values of electrophoretic mobilities and stability constants (association, binding or formation constants) is studied using capillary electrophoresis (CE) and a dynamic mathematical simulator of CE. The study is performed using labile complexes (with fast kinetics) of iron (III) and 5-sulfosalicylate ions (ISC) as an example. It is shown that because the ligand concentration in the analyte zone is not equal to that in BGE, considerable changes in the migration times and electrophoretic mobilities are observed, resulting in systematic errors in the stability constant values. Of crucial significance is the slope of the dependence of the electrophoretic mobility decrease on the ligand equilibrium concentration. Without prior information on this dependence to accurately evaluate the stability constants for similar systems, the total ligand concentration must be at least >50-100 times higher than the total concentration of analyte. Experimental ISC peak fronting and the difference between the direction of the experimental pH dependence of the electrophoretic mobility decrease and the mathematical simulation allow assuming the presence of capillary wall interaction. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. Characterization of gold nanoparticles with different hydrophilic coatings via capillary electrophoresis and Taylor dispersion analysis. Part I: determination of the zeta potential employing a modified analytic approximation.

    PubMed

    Pyell, Ute; Jalil, Alaa H; Pfeiffer, Christian; Pelaz, Beatriz; Parak, Wolfgang J

    2015-07-15

    Taking gold nanoparticles with different hydrophilic coatings as an example, it is investigated whether capillary electrophoresis in combination with Taylor dispersion analysis allows for the precise determination of mean electrophoretic mobilities, electrophoretic mobility distributions, and zeta potentials in a matrix of exactly known composition and the calibration-free determination of number-weighted mean hydrodynamic radii. Our experimental data confirm that the calculation of the zeta potential for colloidal nanoparticles with ζ>25 mV requires to take the relaxation effect into account. Because of the requirement to avoid particle-wall interactions, a solution of disodiumtetraborate decahydrate (borax) in deionized water had been selected as suitable electrolyte. Measurements of the electrophoretic mobility at different ionic strength and application of the analytic approximation developed by Ohshima show that in the present case of a buffered solution with a weak electrolyte co-ion and a strong electrolyte counterion, the effective ionic drag coefficient should be approximated with the ionic drag coefficient of the counterion. The obtained results are in good agreement with theoretical expectations regarding the dependence of the zeta potential and the electrokinetic surface charge density on the ionic strength. We also show that Taylor dispersion analysis (besides estimation of the number-weighted mean hydrodynamic radius) provides additional information on the type and width of the number-weighted particle distribution. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Peak capacity and peak capacity per unit time in capillary and microchip zone electrophoresis.

    PubMed

    Foley, Joe P; Blackney, Donna M; Ennis, Erin J

    2017-11-10

    The origins of the peak capacity concept are described and the important contributions to the development of that concept in chromatography and electrophoresis are reviewed. Whereas numerous quantitative expressions have been reported for one- and two-dimensional separations, most are focused on chromatographic separations and few, if any, quantitative unbiased expressions have been developed for capillary or microchip zone electrophoresis. Making the common assumption that longitudinal diffusion is the predominant source of zone broadening in capillary electrophoresis, analytical expressions for the peak capacity are derived, first in terms of migration time, diffusion coefficient, migration distance, and desired resolution, and then in terms of the remaining underlying fundamental parameters (electric field, electroosmotic and electrophoretic mobilities) that determine the migration time. The latter expressions clearly illustrate the direct square root dependence of peak capacity on electric field and migration distance and the inverse square root dependence on solute diffusion coefficient. Conditions that result in a high peak capacity will result in a low peak capacity per unit time and vice-versa. For a given symmetrical range of relative electrophoretic mobilities for co- and counter-electroosmotic species (cations and anions), the peak capacity increases with the square root of the electric field even as the temporal window narrows considerably, resulting in a significant reduction in analysis time. Over a broad relative electrophoretic mobility interval [-0.9, 0.9], an approximately two-fold greater amount of peak capacity can be generated for counter-electroosmotic species although it takes about five-fold longer to do so, consistent with the well-known bias in migration time and resolving power for co- and counter-electroosmotic species. The optimum lower bound of the relative electrophoretic mobility interval [μ r,Z , μ r,A ] that provides the maximum peak capacity per unit time is a simple function of the upper bound, but its direct application is limited to samples with analytes whose electrophoretic mobilities can be varied independently of electroosmotic flow. For samples containing both co- and counter-electroosmotic ions whose electrophoretic mobilities cannot be easily manipulated, comparable levels of peak capacity and peak capacity per unit time for all ions can be obtained by adjusting the EOF to devote the same amount of time to the separation of each class of ions; this corresponds to μ r,Z =-0.5. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Column-coupling strategies for multidimensional electrophoretic separation techniques.

    PubMed

    Kler, Pablo A; Sydes, Daniel; Huhn, Carolin

    2015-01-01

    Multidimensional electrophoretic separations represent one of the most common strategies for dealing with the analysis of complex samples. In recent years we have been witnessing the explosive growth of separation techniques for the analysis of complex samples in applications ranging from life sciences to industry. In this sense, electrophoretic separations offer several strategic advantages such as excellent separation efficiency, different methods with a broad range of separation mechanisms, and low liquid consumption generating less waste effluents and lower costs per analysis, among others. Despite their impressive separation efficiency, multidimensional electrophoretic separations present some drawbacks that have delayed their extensive use: the volumes of the columns, and consequently of the injected sample, are significantly smaller compared to other analytical techniques, thus the coupling interfaces between two separations components must be very efficient in terms of providing geometrical precision with low dead volume. Likewise, very sensitive detection systems are required. Additionally, in electrophoretic separation techniques, the surface properties of the columns play a fundamental role for electroosmosis as well as the unwanted adsorption of proteins or other complex biomolecules. In this sense the requirements for an efficient coupling for electrophoretic separation techniques involve several aspects related to microfluidics and physicochemical interactions of the electrolyte solutions and the solid capillary walls. It is interesting to see how these multidimensional electrophoretic separation techniques have been used jointly with different detection techniques, for intermediate detection as well as for final identification and quantification, particularly important in the case of mass spectrometry. In this work we present a critical review about the different strategies for coupling two or more electrophoretic separation techniques and the different intermediate and final detection methods implemented for such separations.

  12. Capillary electrophoresis-high resolution sector field inductively coupled plasma mass spectrometry.

    PubMed

    Sonke, Jeroen E; Salters, Vincent J M

    2007-08-03

    The background and applications of high resolution sector field inductively coupled plasma mass spectrometry (HR-ICP-MS) as a detector for capillary (CE) and gel electrophoretic separations are reviewed. Notable progress has been made in the fields of bioinorganic and environmental (geo-) chemistry. Metallomics, the study of metal species interactions and functions in biological systems, puts substantial technical demands on speciation analysis. The combination of high species resolving power (CE) and high sensitivity-high mass resolving power (HR-ICP-MS) provides a solid base to meet such demands.

  13. A new open tubular capillary microextraction and sweeping for the analysis of super low concentration of hydrophobic compounds.

    PubMed

    Xia, Zhining; Gan, Tingting; Chen, Hua; Lv, Rui; Wei, Weili; Yang, Fengqing

    2010-10-01

    A sample pre-concentration method based on the in-line coupling of in-tube solid-phase microextraction and electrophoretic sweeping was developed for the analysis of hydrophobic compounds. The sample pre-concentration and electrophoretic separation processes were simply and sequentially carried out with a (35%-phenyl)-methylpolysiloxane-coated capillary. The developed method was validated and applied to enrich and separate several pharmaceuticals including loratadine, indomethacin, ibuprofen and doxazosin. Several parameters of microextration were investigated such as temperature, pH and eluant. And the concentration of microemulsion that influences separation efficiency and microextraction efficiency were also studied. Central composite design was applied for the optimization of sampling flow rate and sampling time that interact in a very complex way with each other. The precision, sensitivity and recovery of the method were investigated. Under the optimal conditions, the maximum enrichment factors for loratadine, indomethacin, ibuprofen and doxazosin in aqueous solutions are 1355, 571, 523 and 318, respectively. In addition, the developed method was applied to determine loratadine in rabbit blood sample.

  14. Combined electrophoretic-separation and electrospray method and system

    DOEpatents

    Smith, Richard D.; Olivares, Jose A.

    1989-01-01

    A system and method for analyzing molecular constituents of a composition sample includes: forming a solution of the sample, separating the solution by capillary zone electrophoresis into an eluent of constituents longitudinally separated according to their relative electrophoretic mobilities, electrospraying the eluent to form a charged spray in which the molecular constituents have a temporal distribution; and detecting or collecting the separated constituents in accordance with the temporal distribution in the spray. A first high-voltage (e.g., 5-100 KVDC) is applied to the solution. The spray is charged by applying a second high voltage (e.g., .+-.2-8 KVDC) between the eluent at the capillary exit and a cathode spaced in front of the exit. A complete electrical circuit is formed by a conductor which directly contacts the eluent at the capillary exit.

  15. Stereoselective analysis of acid herbicides in natural waters by capillary electrophoresis.

    PubMed

    Polcaro, C M; Marra, C; Desiderio, C; Fanali, S

    1999-09-01

    A capillary electrophoretic method for the stereoselective analysis of aryloxypropionic and aryloxyphenoxypropionic acidic herbicides in ground water and river water was performed. Vancomycin and gamma-cyclodextrin were added to the background electrolyte (BGE) as chiral selectors. Water sample preconcentration was accomplished by solid-phase extraction on styrene-divinylbenzene packed cartridges (2 L of ground water and 1 L of river water). The analytical method allowed for the resolution of mecoprop, fenoprop, fluazifop and haloxyfop racemic mixtures in natural water samples spiked with enantiomer concentration levels in the range 0.1-0.13 ppb for ground water and 0.4-0.54 ppb for river water.

  16. Signal enhancement for peptide analysis in liquid chromatography-electrospray ionization mass spectrometry with trifluoroacetic acid containing mobile phase by postcolumn electrophoretic mobility control.

    PubMed

    Wang, Nan-Hsuan; Lee, Wan-Li; Her, Guor-Rong

    2011-08-15

    A strategy based on postcolumn electrophoretic mobility control (EMC) was developed to alleviate the adverse effect of trifluoroacetic acid (TFA) on the liquid chromatography-mass spectrometry (LC-MS) analysis of peptides. The device created to achieve this goal consisted of a poly(dimethylsiloxane) (PDMS)-based junction reservoir, a short connecting capillary, and an electrospray ionization (ESI) sprayer connected to the outlet of the high-performance liquid chromatography (HPLC) column. By apply different voltages to the junction reservoir and the ESI emitter, an electric field was created across the connecting capillary. Due to the electric field, positively charged peptides migrated toward the ESI sprayer, whereas TFA anions remained in the junction reservoir and were removed from the ionization process. Because TFA did not enter the ESI source, ion suppression from TFA was alleviated. Operation of the postcolumn device was optimized using a peptide standard mixture. Under optimized conditions, signals for the peptides were enhanced 9-35-fold without a compromise in separation efficiency. The optimized conditions were also applied to the LC-MS analysis of a tryptic digest of bovine serum albumin.

  17. Functional integration of PCR amplification and capillary eletrophoresis in a microfabricated DNA analysis device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woolley, A.T.; deMello, A.J.; Mathies, R.A.

    Microfabricated silicon PCR reactors and glass capillary electrophoresis (CE) chips have been successfully coupled to form an integrated DNA analysis system. This construct combines the rapid thermal cycling capabilities of microfabricated PCR devices (10{degree}C/s heating, 2.5{degree}C/s cooling) with the high-speed (<120 s) DNA separations provided by microfabricated CE chips. The PCR chamber and the CE chip were directly linked through a photolithographically fabricated channel filled with hydroxyethylcellulose sieving matrix. Electrophoretic injection directly from the PCR chamber through the cross injection channel was used as an `electrophoretic valve` to couple the PCR and CE devices on-chip. To demonstrate the functionality ofmore » this system, a 15 min PCR amplification of a {Beta}-globin target cloned in m13 was immediately followed by high-speed CE chip separation in under 120 s, providing a rapid PCR-CE analysis in under 20 min. A rapid assay for genomic Salmonella DNA was performed in under 45 min, demonstrating that challenging amplifications of diagnostically interesting targets can also be performed. Real-time monitoring of PCR target amplification in these integrated PCR-CE devices is also feasible. 33 refs., 6 figs.« less

  18. Capillaries for use in a multiplexed capillary electrophoresis system

    DOEpatents

    Yeung, Edward S.; Chang, Huan-Tsang; Fung, Eliza N.

    1997-12-09

    The invention provides a side-entry optical excitation geometry for use in a multiplexed capillary electrophoresis system. A charge-injection device is optically coupled to capillaries in the array such that the interior of a capillary is imaged onto only one pixel. In Sanger-type 4-label DNA sequencing reactions, nucleotide identification ("base calling") is improved by using two long-pass filters to split fluorescence emission into two emission channels. A binary poly(ethyleneoxide) matrix is used in the electrophoretic separations.

  19. Capillaries for use in a multiplexed capillary electrophoresis system

    DOEpatents

    Yeung, E.S.; Chang, H.T.; Fung, E.N.

    1997-12-09

    The invention provides a side-entry optical excitation geometry for use in a multiplexed capillary electrophoresis system. A charge-injection device is optically coupled to capillaries in the array such that the interior of a capillary is imaged onto only one pixel. In Sanger-type 4-label DNA sequencing reactions, nucleotide identification (``base calling``) is improved by using two long-pass filters to split fluorescence emission into two emission channels. A binary poly(ethyleneoxide) matrix is used in the electrophoretic separations. 19 figs.

  20. Single molecule fluorescence burst detection of DNA fragments separated by capillary electrophoresis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haab, B.B.; Mathies, R.A.

    A method has been developed for detecting DNA separated by capillary gel electrophoresis (CGE) using single molecule photon burst counting. A confocal fluorescence microscope was used to observe the fluorescence bursts from single molecules of DNA multiply labeled with the thiazole orange derivative TO6 as they passed through the nearly 2-{mu}m diameter focused laser beam. Amplified photo-electron pulses from the photomultiplier are grouped into bins of 360-450 {mu}s in duration, and the resulting histogram is stored in a computer for analysis. Solutions of M13 DNA were first flowed through the capillary at various concentrations, and the resulting data were usedmore » to optimize the parameters for digital filtering using a low-pass Fourier filter, selecting a discriminator level for peak detection, and applying a peak-calling algorithm. The optimized single molecule counting method was then applied to an electrophoretic separation of M13 DNA and to a separation of pBR 322 DNA from pRL 277 DNA. Clusters of discreet fluorescence bursts were observed at the expected appearance time of each DNA band. The auto-correlation function of these data indicated transit times that were consistent with the observed electrophoretic velocity. These separations were easily detected when only 50-100 molecules of DNA per band traveled through the detection region. This new detection technology should lead to the routine analysis of DNA in capillary columns with an on-column sensitivity of nearly 100 DNA molecules/band or better. 45 refs., 10 figs.« less

  1. Capillary zone electrophoresis for analysis of phytochelatins and other thiol peptides in complex biological samples derivatized with monobromobimane.

    PubMed

    Perez-Rama, Mónica; Torres Vaamonde, Enrique; Abalde Alonso, Julio

    2005-02-01

    A new method to improve the analysis of phytochelatins and their precursors (cysteine, gamma-Glu-Cys, and glutathione) derivatized with monobromobimane (mBrB) in complex biological samples by capillary zone electrophoresis is described. The effects of the background electrolyte pH, concentration, and different organic additives (acetonitrile, methanol, and trifluoroethanol) on the separation were studied to achieve optimum resolution and number of theoretical plates of the analyzed compounds in the electropherograms. Optimum separation of the thiol peptides was obtained with 150 mM phosphate buffer at pH 1.60. Separation efficiency was improved when 2.5% v/v methanol was added to the background electrolyte. The electrophoretic conditions were 13 kV and capillary dimensions with 30 cm length from the inlet to the detector (38 cm total length) and 50 microm inner diameter. The injection was by pressure at 50 mbar for 17 s. Under these conditions, the separation between desglycyl-peptides and phytochelatins was also achieved. We also describe the optimum conditions for the derivatization of biological samples with mBrB to increase electrophoretic sensitivity and number of theoretical plates. The improved method was shown to be simple, reproducible, selective, and accurate in measuring thiol peptides in complex biological samples, the detection limit being 2.5 microM glutathione at a wavelength of 390 nm.

  2. Chromatographic and electrophoretic approaches in ink analysis.

    PubMed

    Zlotnick, J A; Smith, F P

    1999-10-15

    Inks are manufactured from a wide variety of substances that exhibit very different chemical behaviors. Inks designed for use in different writing instruments or printing methods have quite dissimilar components. Since the 1950s chromatographic and electrophoretic methods have played important roles in the analysis of inks, where compositional information may have bearing on the investigation of counterfeiting, fraud, forgery, and other crimes. Techniques such as paper chromatography and electrophoresis, thin-layer chromatography, high-performance liquid chromatography, gas chromatography, gel electrophoresis, and the relatively new technique of capillary electrophoresis have all been explored as possible avenues for the separation of components of inks. This paper reviews the components of different types of inks and applications of the above separation methods are reviewed.

  3. Determination of vanillin in vanilla perfumes and air by capillary electrophoresis.

    PubMed

    Minematsu, Saaya; Xuan, Guang-Shan; Wu, Xing-Zheng

    2013-12-01

    The present study investigated capillary electrophoretic detection of vanillin in vanilla perfume and air. An UV-absorbance detector was used in a home-made capillary electrophoretic instrument. A fused silica capillary (outer diameter: 364 μm, inner diameter: 50 μm) was used as a separation capillary, and a high electric voltage (20 kV) was applied across the two ends of the capillary. Total length of the capillary was 70 cm, and the effective length was 55 cm. Experimental results showed that the vanillin peak was detected at about 600, 450, and 500 seconds when pH of running buffers in CE were 7.2, 9.3, and 11.5, respectively. The peak area of vanillin was proportional to its concentration in the range of 0-10(-2) mol/L. The detection limit was about 10(-5) mol/L. Vanillin concentration in a 1% vanilla perfume sample was determined to be about 3×10(-4) mol/L, agreed well with that obtained by a HPLC method. Furthermore, determination of vanillin in air by combination of CE and active carbon adsorption method was investigated. Copyright © 2013 The Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences. Published by Elsevier B.V. All rights reserved.

  4. Capillary Electrophoresis Sensitivity Enhancement Based on Adaptive Moving Average Method.

    PubMed

    Drevinskas, Tomas; Telksnys, Laimutis; Maruška, Audrius; Gorbatsova, Jelena; Kaljurand, Mihkel

    2018-06-05

    In the present work, we demonstrate a novel approach to improve the sensitivity of the "out of lab" portable capillary electrophoretic measurements. Nowadays, many signal enhancement methods are (i) underused (nonoptimal), (ii) overused (distorts the data), or (iii) inapplicable in field-portable instrumentation because of a lack of computational power. The described innovative migration velocity-adaptive moving average method uses an optimal averaging window size and can be easily implemented with a microcontroller. The contactless conductivity detection was used as a model for the development of a signal processing method and the demonstration of its impact on the sensitivity. The frequency characteristics of the recorded electropherograms and peaks were clarified. Higher electrophoretic mobility analytes exhibit higher-frequency peaks, whereas lower electrophoretic mobility analytes exhibit lower-frequency peaks. On the basis of the obtained data, a migration velocity-adaptive moving average algorithm was created, adapted, and programmed into capillary electrophoresis data-processing software. Employing the developed algorithm, each data point is processed depending on a certain migration time of the analyte. Because of the implemented migration velocity-adaptive moving average method, the signal-to-noise ratio improved up to 11 times for sampling frequency of 4.6 Hz and up to 22 times for sampling frequency of 25 Hz. This paper could potentially be used as a methodological guideline for the development of new smoothing algorithms that require adaptive conditions in capillary electrophoresis and other separation methods.

  5. Nonaqueous capillary electrophoresis of dextromethorphan and its metabolites.

    PubMed

    Pelcová, Marta; Langmajerová, Monika; Cvingráfová, Eliška; Juřica, Jan; Glatz, Zdeněk

    2014-10-01

    This study deals with the nonaqueous capillary electrophoretic separation of dextromethorphan and its metabolites using a methanolic background electrolyte. The optimization of separation conditions was performed in terms of the resolution of dextromethorphan and dextrorphan and the effect of separation temperature, voltage, and the characteristics of the background electrolyte were studied. Complete separation of all analytes was achieved in 40 mM ammonium acetate dissolved in methanol. Hydrodynamic injection was performed at 3 kPa for 4 s. The separation voltage was 20 kV accompanied by a low electric current. The ultraviolet detection was performed at 214 nm, the temperature of the capillary was 25°C. These conditions enabled the separation of four analytes plus the internal standard within 9 min. Further, the developed method was validated in terms of linearity, sensitivity, and repeatability. Rat liver perfusate samples were subjected to the nonaqueous capillary electrophoretic method to illustrate its applicability. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Combined electrophoretic-separation and electrospray method and system

    DOEpatents

    Smith, R.D.; Olivares, J.A.

    1989-06-27

    A system and method for analyzing molecular constituents of a composition sample includes: forming a solution of the sample, separating the solution by capillary zone electrophoresis into an eluent of constituents longitudinally separated according to their relative electrophoretic mobilities, electrospraying the eluent to form a charged spray in which the molecular constituents have a temporal distribution; and detecting or collecting the separated constituents in accordance with the temporal distribution in the spray. A first high-voltage (e.g., 5--100 kVDC) is applied to the solution. The spray is charged by applying a second high voltage (e.g., [+-]2--8 kVDC) between the eluent at the capillary exit and a cathode spaced in front of the exit. A complete electrical circuit is formed by a conductor which directly contacts the eluent at the capillary exit. 10 figs.

  7. Photothermal trace detection in capillary electrophoresis for biomedical diagnostics and toxic materials (invited)

    NASA Astrophysics Data System (ADS)

    Faubel, Werner; Heissler, Stefan; Pyell, Ute; Ragozina, Natalia

    2003-01-01

    Two applications of a near-field thermal lens capillary electrophoresis detector in the deep ultraviolet region (pump beam 257 nm wavelength) will be presented: (1) Capillary electrophoretic determination of the pharmaceuticals Tramadol, Verapamil, and Papaverin. Direct separation techniques were used for the different classes of substances with characteristic absorbance spectra. The combination of capillary electrophoresis and the highly sensitive detection with thermal lens spectroscopy permits the analysis of nanoliter volume samples common in biomedical diagnostics without any preconcentration step. (2) The determination of (nonfluorescent) nitro aromatic explosives in contaminated soil. These compounds are detected with the laboratory built thermal lens detector after their separation by micellar electrokinetic chromatography. Its shown that this type of detection makes it possible to obtain limits of detection 1-2 orders of magnitude lower than those obtained with classical absorption spectrometric detection.

  8. Chiral separation of 3,4-methylenedioxymeth- amphetamine and related compounds in clandestine tablets and urine samples by capillary electrophoresis/fluorescence spectroscopy.

    PubMed

    Huang, Yu-San; Liu, Ju-Tsung; Lin, Li-Chang; Lin, Cheng-Huang

    2003-03-01

    The R-(-)- and S-(+)-isomers of 3,4-methylenedioxymethamphetamine (MDMA) and its metabolite 3,4-methylenedioxyamphetamine (MDA) were prepared, identified by gas chromatography/mass spectrometry (GC/MS) and then used as standards in a series of capillary electrophoresis (CE) experiments. Using these R-(-)- and S-(+)-isomers, the distribution of (RS)-MDA and (RS)-MDMA stereoisomers in clandestine tablets and suspect urine samples were identified. Several electrophoretic parameters, such as the concentration of beta-cyclodextrin used in the electrophoretic separation and the amount of organic solvents required for the separation, were optimized.

  9. Multiplexed capillary electrophoresis system

    DOEpatents

    Yeung, Edward S.; Li, Qingbo; Lu, Xiandan

    1998-04-21

    The invention provides a side-entry optical excitation geometry for use in a multiplexed capillary electrophoresis system. A charge-injection device is optically coupled to capillaries in the array such that the interior of a capillary is imaged onto only one pixel. In Sanger-type 4-label DNA sequencing reactions, nucleotide identification ("base calling") is improved by using two long-pass filters to split fluorescence emission into two emission channels. A binary poly(ethyleneoxide) matrix is used in the electrophoretic separations.

  10. Multiplexed capillary electrophoresis system

    DOEpatents

    Yeung, Edward S.; Chang, Huan-Tsang; Fung, Eliza N.; Li, Qingbo; Lu, Xiandan

    1996-12-10

    The invention provides a side-entry optical excitation geometry for use in a multiplexed capillary electrophoresis system. A charge-injection device is optically coupled to capillaries in the array such that the interior of a capillary is imaged onto only one pixel. In Sanger-type 4-label DNA sequencing reactions, nucleotide identification ("base calling") is improved by using two long-pass filters to split fluorescence emission into two emission channels. A binary poly(ethyleneoxide) matrix is used in the electrophoretic separations.

  11. Multiplexed capillary electrophoresis system

    DOEpatents

    Yeung, E.S.; Li, Q.; Lu, X.

    1998-04-21

    The invention provides a side-entry optical excitation geometry for use in a multiplexed capillary electrophoresis system. A charge-injection device is optically coupled to capillaries in the array such that the interior of a capillary is imaged onto only one pixel. In Sanger-type 4-label DNA sequencing reactions, nucleotide identification (``base calling``) is improved by using two long-pass filters to split fluorescence emission into two emission channels. A binary poly(ethyleneoxide) matrix is used in the electrophoretic separations. 19 figs.

  12. Multiplexed capillary electrophoresis system

    DOEpatents

    Yeung, E.S.; Chang, H.T.; Fung, E.N.; Li, Q.; Lu, X.

    1996-12-10

    The invention provides a side-entry optical excitation geometry for use in a multiplexed capillary electrophoresis system. A charge-injection device is optically coupled to capillaries in the array such that the interior of a capillary is imaged onto only one pixel. In Sanger-type 4-label DNA sequencing reactions, nucleotide identification (``base calling``) is improved by using two long-pass filters to split fluorescence emission into two emission channels. A binary poly(ethyleneoxide) matrix is used in the electrophoretic separations. 19 figs.

  13. Analysis of nitrites and nitrates in hams and sausages by open-tubular capillary electrochromatography with a nanolatex-coated capillary column.

    PubMed

    Zhang, Yanhao; Tian, Xiangyu; Guo, Yaxiao; Li, Haibin; Yu, Ajuan; Deng, Zhifen; Sun, Barry Baoguo; Zhang, Shusheng

    2014-04-16

    In this work, a new open-tubular capillary electrochromatography (OT-CEC) method with the nanolatex-coated column was proposed for the determination of nitrites and nitrates in foodstuffs. The method was simple and repeatable as a result of avoiding the introduction of an electroosmotic flow reverse additive (such as cetyltrimethylammonium chloride) in electrophoretic buffer. The limits of quantitation were 0.89 and 1.05 mg kg⁻¹ for nitrate and nitrite, respectively, whereas the overall recoveries ranged from 94 to 103%. The developed OT-CEC method was successfully applied for 12 samples, and the residue profiles of nitrites and nitrates in hams and sausages were obtained and evaluated.

  14. Microfabricated capillary electrophoresis chip and method for simultaneously detecting multiple redox labels

    DOEpatents

    Mathies, Richard A.; Singhal, Pankaj; Xie, Jin; Glazer, Alexander N.

    2002-01-01

    This invention relates to a microfabricated capillary electrophoresis chip for detecting multiple redox-active labels simultaneously using a matrix coding scheme and to a method of selectively labeling analytes for simultaneous electrochemical detection of multiple label-analyte conjugates after electrophoretic or chromatographic separation.

  15. Native and sodium dodecyl sulfate-capillary gel electrophoresis of proteins on a single microchip.

    PubMed

    Tsai, Shuo-Wen; Loughran, Michael; Suzuki, Hiroaki; Karube, Isao

    2004-02-01

    Simultaneous electrophoresis of both native and Sodium dodecyl sulfate (SDS) proteins was observed on a single microchip within 20 min. The capillary array prevented lateral diffusion of SDS components and avoided cross contamination of native protein samples. The planar sputtered electrode format provided a more uniform distribution of separation voltage into each of the 36 parallel microchannel capillaries than platinum wire electrodes commonly used in conventional electrophoresis. The customized geometry of the stacking capillary machined into the cover plate of the microchip facilitated reproducible sample injection without the requirement for stacking gel. Polyimide served as a mask and facilitated insulation of the anode and cathode to prevent electrode lift off and deterioration during continuous electrophoresis, even at a constant current of 8 mA. Improved protein separation was observed during capillary electrophoresis at lower currents. Ferguson plot analysis confirmed the electrophoretic mobility of native globular proteins in accordance with their charge and size. Corresponding Ferguson plot analysis of SDS-associated proteins on the same chip confirmed separation of marker proteins according to their molecular weight.

  16. Measurement of monomolecular binding constants of neutral phenols into the beta-cyclodextrin by continuous frontal analysis in capillary and microchip electrophoresis via a competitive assay.

    PubMed

    Le Saux, Thomas; Hisamoto, Hideaki; Terabe, Shigeru

    2006-02-03

    Measurement of binding constant by chip electrophoresis is a very promising technique for the high throughput screening of non-covalent interactions. Among the different electrophoretic methods available that yield the binding parameters, continuous frontal analysis is the most appropriate for a transposition from capillary electrophoresis (CE) to microchip electrophoresis. Implementation of this methodology in microchip was exemplified by the measurement of inclusion constants of 2-naphtalenesulfonate and neutral phenols (phenol, 4-chlorophenol and 4-nitrophenol) into beta-cyclodextrin by competitive assays. The issue of competitor choice is discussed in relation to its appropriateness for proper monitoring of the interaction.

  17. Recent advances in capillary electrophoretic migration techniques for pharmaceutical analysis.

    PubMed

    Deeb, Sami El; Wätzig, Hermann; El-Hady, Deia Abd; Albishri, Hassan M; de Griend, Cari Sänger-van; Scriba, Gerhard K E

    2014-01-01

    Since the introduction about 30 years ago, CE techniques have gained a significant impact in pharmaceutical analysis. The present review covers recent advances and applications of CE for the analysis of pharmaceuticals. Both small molecules and biomolecules such as proteins are considered. The applications range from the determination of drug-related substances to the analysis of counterions and the determination of physicochemical parameters. Furthermore, general considerations of CE methods in pharmaceutical analysis are described. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Capillary electrophoretic determination of main components of natural dyes with MS detection.

    PubMed

    Surowiec, Izabella; Pawelec, Katarzyna; Rezeli, Melinda; Kilar, Ferenc; Trojanowicz, Marek

    2008-07-01

    CE with UV-Vis and MS detections was investigated as a technique for detection of main components of selected natural dyes of plant and insect origin. The BGE giving the best separation of the investigated flavonoids and anthraquinoids, suitable for MS detection consisted of 40 mM ammonium acetate solution of pH 9.5 with 40% ACN. LODs obtained with MS detection were even one order of magnitude lower than the ones obtained with UV-Vis detection. Application of MS detection enabled determination of eleven dye compounds from three different chemical groups in 15 min. and proved to be more satisfactory than diode-array detection in the electrophoretic analysis of main classes of natural dyes both in terms of selectivity and sensitivity of analysis.

  19. Characterization of complexes between phenethylamine enantiomers and β-cyclodextrin derivatives by capillary electrophoresis-Determination of binding constants and complex mobilities.

    PubMed

    Wahl, Joachim; Furuishi, Takayuki; Yonemochi, Etsuo; Meinel, Lorenz; Holzgrabe, Ulrike

    2017-04-01

    To optimize chiral separation conditions and to improve the knowledge of enantioseparation, it is important to know the binding constants K between analytes and cyclodextrins and the electrophoretic mobilities of the temporarily formed analyte-cyclodextrin-complexes. K values for complexes between eight phenethylamine enantiomers, namely ephedrine, pseudoephedrine, methylephedrine and norephedrine, and four different β-cyclodextrin derivatives were determined by affinity capillary electrophoresis. The binding constants were calculated from the electrophoretic mobility values of the phenethylamine enantiomers at increasing concentrations of cyclodextrins in running buffer. Three different linear plotting methods (x-reciprocal, y-reciprocal, double reciprocal) and nonlinear regression were used for the determination of binding constants with β-cyclodextrin, (2-hydroxypropyl)-β-cyclodextrin, methyl-β-cyclodextrin and 6-O-α-maltosyl-β-cyclodextrin. The cyclodextrin concentration in a 50 mM phosphate buffer pH 3.0 was varied from 0 to 12 mM. To investigate the influence of the binding constant values on the enantioseparation the observed electrophoretic selectivities were compared with the obtained K values and the calculated enantiomer-cyclodextrin-complex mobilities. The different electrophoretic mobilities of the temporarily formed complexes were crucial factors for the migration order and enantioseparation of ephedrine derivatives. To verify the apparent binding constants determined by capillary electrophoresis, a titration process using ephedrine enantiomers and β-cyclodextrin was carried out. Furthermore, the isothermal titration calorimetry measurements gave information about the thermal properties of the complexes. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Factors affecting the separation performance of proteins in capillary electrophoresis.

    PubMed

    Zhu, Yueping; Li, Zhenqing; Wang, Ping; Shen, Lisong; Zhang, Dawei; Yamaguchi, Yoshinori

    2018-04-15

    Capillary electrophoresis (CE) is an effective tool for protein separation and analysis. Compared with capillary gel electrophoresis (CGE), non-gel sieving capillary electrophoresis (NGSCE) processes the superiority on operation, repeatability and automaticity. Herein, we investigated the effect of polymer molecular weight and concentration, electric field strength, and the effective length of the capillary on the separation performance of proteins, and find that (1) polymer with high molecular weight and concentration favors the separation of proteins, although concentrated polymer hinders its injection into the channel of the capillary due to its high viscosity. (2) The resolution between the adjacent proteins decreases with the increase of electric field strength. (3) When the effective length of the capillary is long, the separation performance improves at the cost of separation time. (4) 1.4% (w/v) hydroxyethyl cellulose (HEC), 100 V/cm voltage and 12 cm effective length offers the best separation for the proteins with molecular weight from 14,400 Da to 97,400 Da. Finally, we employed the optimal electrophoretic conditions to resolve Lysozyme, Ovalbumin, BSA and their mixtures, and found that they were baseline resolved within 15 min. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Triblock copolymer matrix-based capillary electrophoretic microdevice for high-resolution multiplex pathogen detection.

    PubMed

    Kim, Se Jin; Shin, Gi Won; Choi, Seok Jin; Hwang, Hee Sung; Jung, Gyoo Yeol; Seo, Tae Seok

    2010-03-01

    Rapid and simple analysis for the multiple target pathogens is critical for patient management. CE-SSCP analysis on a microchip provides high speed, high sensitivity, and a portable genetic analysis platform in molecular diagnostic fields. The capability of separating ssDNA molecules in a capillary electrophoretic microchannel with high resolution is a critical issue to perform the precise interpretation in the electropherogram. In this study, we explored the potential of poly(ethyleneoxide)-poly(propyleneoxide)-poly(ethyleneoxide) (PEO-PPO-PEO) triblock copolymer as a sieving matrix for CE-SSCP analysis on a microdevice. To demonstrate the superior resolving power of PEO-PPO-PEO copolymers, 255-bp PCR amplicons obtained from 16S ribosomal RNA genes of four bacterial species, namely Proteus mirabilis, Haemophilus ducreyi, Pseudomonas aeruginosa, and Neisseria meningitidis, were analyzed in the PEO-PPO-PEO matrix in comparison with 5% linear polyacrylamide and commercial GeneScan gel. Due to enhanced dynamic coating and sieving ability, PEO-PPO-PEO copolymer displayed fourfold enhancement of resolving power in the CE-SSCP to separate same-sized DNA molecules. Fivefold input of genomic DNA of P. aeruginosa and/or N. meningitidis produced proportionally increased corresponding amplicon peaks, enabling correct quantitative analysis in the pathogen detection. Besides the high-resolution sieving capability, a facile loading and replenishment of gel in the microchannel due to thermally reversible gelation property makes PEO-PPO-PEO triblock copolymer an excellent matrix in the CE-SSCP analysis on the microdevice.

  2. Particle sizer and DNA sequencer

    DOEpatents

    Olivares, Jose A.; Stark, Peter C.

    2005-09-13

    An electrophoretic device separates and detects particles such as DNA fragments, proteins, and the like. The device has a capillary which is coated with a coating with a low refractive index such as Teflon.RTM. AF. A sample of particles is fluorescently labeled and injected into the capillary. The capillary is filled with an electrolyte buffer solution. An electrical field is applied across the capillary causing the particles to migrate from a first end of the capillary to a second end of the capillary. A detector light beam is then scanned along the length of the capillary to detect the location of the separated particles. The device is amenable to a high throughput system by providing additional capillaries. The device can also be used to determine the actual size of the particles and for DNA sequencing.

  3. Electrophoretic analysis of quinone anion radicals in acetonitrile solutions using an on-line radical generator.

    PubMed

    Esaka, Yukihiro; Okumura, Noriko; Uno, Bunji; Goto, Masashi

    2003-05-01

    We have investigated analysis of anion radicals of phenanthrenequinone (PhQ) and anthraquinone (AQ) using acetonitrile-capillary electrophoresis (CE) under anaerobic conditions. PhQ and AQ have relatively high negative reduction potentials meaning that their anion radicals are re-oxidized quite readily by the surrounding O(2) to disappear during analysis and we failed to detect them with our previous system. In this work, we have developed an on-line system combining a unique electrolysis cell for generation of the radicals and a CE unit to keep the analysis system free from external O(2) molecules and to reduce analysis time remarkably. As a result, electrophoretic detection of the anion radicals of PhQ and AQ has been achieved. Furthermore, we have observed hydrogen-bonding interaction between the anion radicals and dimethylurea (DMU) using the present system and have indicated a characteristic interaction of the anion radical of PhQ as an ortho-quinone with DMU.

  4. Metabolic profiling for the identification of Huntington biomarkers by on-line solid-phase extraction capillary electrophoresis mass spectrometry combined with advanced data analysis tools.

    PubMed

    Pont, Laura; Benavente, Fernando; Jaumot, Joaquim; Tauler, Romà; Alberch, Jordi; Ginés, Silvia; Barbosa, José; Sanz-Nebot, Victoria

    2016-03-01

    In this work, an untargeted metabolomic approach based on sensitive analysis by on-line solid-phase extraction capillary electrophoresis mass spectrometry (SPE-CE-MS) in combination with multivariate data analysis is proposed as an efficient method for the identification of biomarkers of Huntington's disease (HD) progression in plasma. For this purpose, plasma samples from wild-type (wt) and HD (R6/1) mice of different ages (8, 12, and 30 weeks), were analyzed by C18 -SPE-CE-MS in order to obtain the characteristic electrophoretic profiles of low molecular mass compounds. Then, multivariate curve resolution alternating least squares (MCR-ALS) was applied to the multiple full scan MS datasets. This strategy permitted the resolution of a large number of metabolites being characterized by their electrophoretic peaks and their corresponding mass spectra. A total number of 29 compounds were relevant to discriminate between wt and HD plasma samples, as well as to follow-up the HD progression. The intracellular signaling was found to be the most affected metabolic pathway in HD mice after 12 weeks of birth, when mice already showed motor coordination deficiencies and cognitive decline. This fact agreed with the atrophy and dysfunction of specific neurons, loss of several types of receptors, and changed expression of neurotransmitters. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Optimal MEMS device for mobility and zeta potential measurements using DC electrophoresis.

    PubMed

    Karam, Pascal R; Dukhin, Andrei; Pennathur, Sumita

    2017-05-01

    We have developed a novel microchannel geometry that allows us to perform simple DC electrophoresis to measure the electrophoretic mobility and zeta potential of analytes and particles. In standard capillary geometries, mobility measurements using DC fields are difficult to perform. Specifically, measurements in open capillaries require knowledge of the hard to measure and often dynamic wall surface potential. Although measurements in closed capillaries eliminate this requirement, the measurements must be performed at infinitesimally small regions of zero flow where the pressure driven-flow completely cancels the electroosmotic flow (Komagata Planes). Furthermore, applied DC fields lead to electrode polarization, further questioning the reliability and accuracy of the measurement. In contrast, our geometry expands and moves the Komagata planes to where velocity gradients are at a minimum, and thus knowledge of the precise location of a Komagata plane is not necessary. Additionally, our microfluidic device prevents electrode polarization because of fluid recirculation around the electrodes. We fabricated our device using standard MEMS fabrication techniques and performed electrophoretic mobility measurements on 500 nm fluorescently tagged polystyrene particles at various buffer concentrations. Results are comparable to two different commercial dynamic light scattering based particle sizing instruments. We conclude with guidelines to further develop this robust electrophoretic tool that allows for facile and efficient particle characterization. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Single-step enantioselective amino acid flux analysis by capillary electrophoresis using on-line sample preconcentration with chemical derivatization.

    PubMed

    Ptolemy, Adam S; Tran, Lara; Britz-McKibbin, Philip

    2006-07-15

    Capillary electrophoresis (CE) represents a versatile platform for integrating sample pretreatment with chemical analysis because of its ability to tune analyte electromigration and band dispersion properties in discontinuous electrolyte systems. In this article, a single-step method that combines on-line sample preconcentration with in-capillary chemical derivatization is developed for rapid, sensitive, and enantioselective analysis of micromolar levels of amino acids that lack intrinsic chromophores by CE with UV detection. Time-resolved electrophoretic studies revealed two distinct stages of amino acid band narrowing within the original long sample injection plug occurring both prior to and after in-capillary labeling via zone passing by ortho-phthalaldehyde/N-acetyl l-cysteine (OPA/NAC). This technique enabled direct analysis of d-amino acids in a 95% enantiomeric excess mixture with sub-micromolar detection limits and minimal sample handling, where the capillary functions as a preconcentrator, microreactor, and chiral selector. On-line sample preconcentration with chemical derivatization CE (SPCD-CE) was applied to study the enantioselective amino acid flux in Escherichia coli bacteria cultures, which demonstrated a unique l-Ala efflux into the extracellular medium. New strategies for high-throughput analyses of low-abundance metabolites are important for understanding fundamental physiological processes in bacteria required for screening the efficacy of new classes of antibiotics as well as altered metabolism in genetically modified mutant strains.

  7. New methodology for capillary electrophoresis with ESI-MS detection: Electrophoretic focusing on inverse electromigration dispersion gradient. High-sensitivity analysis of sulfonamides in waters.

    PubMed

    Malá, Zdena; Gebauer, Petr; Boček, Petr

    2016-09-07

    This article describes for the first time the combination of electrophoretic focusing on inverse electromigration dispersion (EMD) gradient, a new separation principle described in 2010, with electrospray-ionization (ESI) mass spectrometric detection. The separation of analytes along the electromigrating EMD profile proceeds so that each analyte is focused and concentrated within the profile at a particular position given by its pKa and ionic mobility. The proposed methodology combines this principle with the transport of the focused zones to the capillary end by superimposed electromigration, electroosmotic flow and ESI suction, and their detection by the MS detector. The designed electrolyte system based on maleic acid and 2,6-lutidine is suitable to create an inverse EMD gradient of required properties and its components are volatile enough to be compatible with the ESI interface. The characteristic properties of the proposed electrolyte system and of the formed inverse gradient are discussed in detail using calculated diagrams and computer simulations. It is shown that the system is surprisingly robust and allows sensitive analyses of trace amounts of weak acids in the pKa range between approx. 6 and 9. As a first practical application of electrophoretic focusing on inverse EMD gradient, the analysis of several sulfonamides in waters is reported. It demonstrates the potential of the developed methodology for fast and high-sensitivity analyses of ionic trace analytes, with reached LODs around 3 × 10(-9) M (0.8 ng mL(-1)) of sulfonamides in spiked drinking water without any sample pretreatment. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. ssDNA degradation along capillary electrophoresis process using a Tris buffer.

    PubMed

    Ric, Audrey; Ong-Meang, Varravaddheay; Poinsot, Verena; Martins-Froment, Nathalie; Chauvet, Fabien; Boutonnet, Audrey; Ginot, Frédéric; Ecochard, Vincent; Paquereau, Laurent; Couderc, François

    2017-06-01

    Tris-Acetate buffer is currently used in the selection and the characterization of ssDNA by capillary electrophoresis (CE). By applying high voltage, the migration of ionic species into the capillary generates a current that induces water electrolysis. This phenomenon is followed by the modification of the pH and the production of Tris derivatives. By injecting ten times by capillary electrophoresis ssDNA (50 nM), the whole oligonucleotide was degraded. In this paper, we will show that the Tris buffer in the running vials is modified along the electrophoretic process by electrochemical reactions. We also observed that the composition of the metal ions changes in the running buffer vials. This phenomenon, never described in CE, is important for fluorescent ssDNA analysis using Tris buffer. The oligonucleotides are degraded by electrochemically synthesized species (present in the running Tris vials) until it disappears, even if the separation buffer in the capillary is clean. To address these issues, we propose to use a sodium phosphate buffer that we demonstrate to be electrochemically inactive. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Simultaneous sizing and electrophoretic mobility measurement of sub-micron particles using Brownian motion

    PubMed Central

    Palanisami, Akilan; Miller, John H.

    2011-01-01

    The size and surface chemistry of micron scale particles are of fundamental importance in studies of biology and air particulate pollution. However, typical electrophoretic measurements of these and other sub-micron scale particles (300 nm – 1 μm) cannot resolve size information within heterogeneous mixtures unambiguously. Using optical microscopy, we monitor electrophoretic motion together with the Brownian velocity fluctuations—using the latter to measure size by either the Green-Kubo relation or by calibration from known size standards. Particle diameters are resolved to ±12% with 95% confidence. Strikingly, the size resolution improves as particle size decreases due to the increased Brownian motion. The sizing ability of the Brownian assessed electrophoresis method described here complements the electrophoretic mobility resolution of traditional capillary electrophoresis. PMID:20882556

  10. Aggregation behavior of fullerenes in aqueous solutions: a capillary electrophoresis and asymmetric flow field-flow fractionation study.

    PubMed

    Astefanei, Alina; Núñez, Oscar; Galceran, Maria Teresa; Kok, Wim Th; Schoenmakers, Peter J

    2015-10-01

    In this work, the electrophoretic behavior of hydrophobic fullerenes [buckminsterfullerene (C60), C70, and N-methyl-fulleropyrrolidine (C60-pyrr)] and water-soluble fullerenes [fullerol (C60(OH)24); polyhydroxy small gap fullerene, hydrated (C120(OH)30); C60 pyrrolidine tris acid (C60-pyrr tris acid); and (1,2-methanofullerene C60)-61-carboxylic acid (C60CHCOOH)] in micellar electrokinetic capillary chromatography (MECC) was evaluated. The aggregation behavior of the water-soluble compounds in MECC at different buffer and sodium dodecyl sulfate (SDS) concentrations and pH values of the background electrolyte (BGE) was studied by monitoring the changes observed in the electrophoretic pattern of the peaks. Broad and distorted peaks that can be attributed to fullerene aggregation were obtained in MECC which became narrower and more symmetric by working at low buffer and SDS concentrations (below the critical micelle concentration, capillary zone electrophoresis (CZE) conditions). For the characterization of the suspected aggregates formed (size and shape), asymmetrical flow field-flow fractionation (AF4) and transmission electron microscopy (TEM) were used. The results showed that the increase in the buffer concentration promoted the aggregation of the particles, while the presence of SDS micelles revealed multiple peaks corresponding to particles of different aggregation degrees. Furthermore, MECC has been applied for the first time for the analysis of C60 in two different cosmetic products (i.e., anti-aging serum and facial mask).

  11. Potential of capillary zone electrophoresis for estimation of humate acid-base properties.

    PubMed

    Vanifatova, Natalia G; Zavarzina, Anna G; Spivakov, Boris Ya

    2008-03-07

    Capillary zone electrophoresis (CZE) has been applied for fractionation and characterization of soil-derived humic acids (HAs). Humic acids from soddy-podzolic (HA(s)) and chernozem (HA(ch)) soils were studied as well as hydrophobic high-molecular-weight (HMW) and hydrophilic low-molecular-weight (LMW) HA(s) fractions obtained by salting-out with ammonium sulfate at a saturation of 0-40% and >70%, respectively. The possibility of CZE partial fractionation of HAs has been demonstrated. The shape of "humic hump" was shown to depend on the pH of running electrolyte. Almost the whole peak overlapping occurred if alkaline solutions were used for fractionation, but the peak resolution was improved at pH 5-7. Under appropriate fractionation conditions (pH 7), at least three humic acid subfractions with different electrophoretic mobilities were distinguished in the electropherograms of initial HA and HA(s) fractions. Such a high peak resolution has never been achieved for humic acids before. The presence of three subfractions in the HA is in agreement with gel-filtration analysis and was confirmed by comparison of the electrophoretic behavior of HA(s) with those of its HMW (hydrophobic) and the LMW (hydrophilic) fractions. The potentiometric titration of HA and its fractions was performed and the pK(a) of the functional groups were calculated. An attempt was made for the first time to relate the variation of electrophoretic mobility values with acid-base properties of humic acids. It was shown that changes in the humate charge resulting from the variation of the ionization degree of its functional groups as a function of pH can be estimated on the basis of electrophoretic mobility values. Potential of CZE in estimation of HA isoelectric point was demonstrated. The pH value corresponding to the lowest absolute electrophoretic mobility value of about 20 x 10(-5) cm(2) V(-1) s(-1) can be used for approximate estimation of HA isoelectric point. The data were discussed and agreement with the random coil structural model has been shown.

  12. Dual-opposite injection capillary electrophoresis: Principles and misconceptions.

    PubMed

    Blackney, Donna M; Foley, Joe P

    2017-03-01

    Dual-opposite injection capillary electrophoresis (DOI-CE) is a separation technique that utilizes both ends of the capillary for sample introduction. The electroosmotic flow (EOF) is suppressed to allow all ions to reach the detector quickly. Depending on the individual electrophoretic mobilities of the analytes of interest and the effective length that each analyte travels to the detection window, the elution order of analytes in a DOI-CE separation can vary widely. This review discusses the principles, applications, and limitations of dual-opposite injection capillary electrophoresis. Common misconceptions regarding DOI-CE are clarified. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Separation of oligopeptides, nucleobases, nucleosides and nucleotides using capillary electrophoresis/electrochromatography with sol-gel modified inner capillary wall.

    PubMed

    Svobodová, Jana; Kofroňová, Olga; Benada, Oldřich; Král, Vladimír; Mikšík, Ivan

    2017-09-29

    The aim of this article is to study the modification of an inner capillary wall with sol-gel coating (pure silica sol-gel or silica sol-gel containing porphyrin-brucine conjugate) and determine its influence on the separation process using capillary electrophoresis/electrochromatography method. After modification of the inner capillary surface the separation of analytes was performed using two different phosphate buffers (pH 2.5 and 9.0) and finally the changes in electrophoretic mobilities of various samples were calculated. To confirm that the modification of the inner capillary surface was successful, the parts of the inner surfaces of capillaries were observed using scanning electron microscopy. The analytes used as testing samples were oligopeptides, nucleosides, nucleobases and finally nucleotides. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Electrophoretic studies of polygalacturonate oligomers and their interactions with metal ions.

    PubMed

    Wiedmer, S K; Cassely, A; Hong, M; Novotny, M V; Riekkola, M L

    2000-09-01

    Polygalacturonic acid, a linear homopolysaccharide, was investigated by capillary electrophoresis (CE) using linear polyacrylamide-coated capillaries and laser-induced fluorescence (LIF) detection. A successful separation of its fluorescently labeled oligomers was achieved through sieving in polyacrylamide entangled matrices. The reaction conditions for the derivatization of polygalacturonic acid were optimized. In studying the interactions between polygalacturonic acid and various metal ions, the end-label, free-solution electrophoretic (ELFSE) technique, developed earlier in our laboratory (Sudor, J., Novotny, M. V., Anal. Chem. 1995, 67, 4205-4209) was found preferable to the sieving method. ELFSE is fast and convenient in that no polymer solutions are needed for the separation. The investigation showed that for the moderately large oligomers, the strongest binding occurred with calcium and cadmium ions, while the smallest interaction was observed with magnesium ions.

  15. Simultaneous determination of five tetracycline and macrolide antibiotics in feeds using HPCE.

    PubMed

    Tong, Jing; Rao, Qinxiong; Zhu, Kui; Jiang, Zhigang; Ding, Shuangyang

    2009-12-01

    This work demonstrates the potential of HPCE in the analysis of antibiotics in a complex matrix such as feedstuffs. Using 20 mM citric acid-40 mM Na(2)HPO(4) buffer (pH 2.65), the five antibiotics, tetracycline, oxytetracycline, doxycycline, tilmicosin, and tylosin were successfully separated at 30 kV in a 64.5 cm x 75 microm id capillary. Good repeatability, stability, and reliability of the method were supported by <10% CV with mean recoveries of >70%, and the limit of detection of the five analytes was 0.5-1 mg/kg. It was for the first time that a capillary electrophoretic method was employed to simultaneously detect five tetracycline and macrolide antibiotics in animal feeds.

  16. Electro-Optical Platform for the Manipulation of Live Cells

    DTIC Science & Technology

    2002-10-02

    system, other physical forces may play a significant role. In particular, electroosmotic forces that cause fluid movement relative to a surface can...occur due to the mobility of ions in solution. Electroosmotic forces are commonly utilized in capillary electrophoretic separa- tion, where the capillary...fluid motion that acts to entrain particles to be separated.46 Thus, in the chamber presented here, the patterned anode can induce electroosmotic flow

  17. Mechanism of molecular recognition on molecular imprinted monolith by capillary electrochromatography.

    PubMed

    Liu, Zhao-Sheng; Xu, Yan-Li; Yan, Chao; Gao, Ru-Yu

    2005-09-16

    The recognition mechanism of molecularly imprinted polymer (MIP) in capillary electrochromatography (CEC) is complicated since it possesses a hybrid process, which comprises the features of chromatographic retention, electrophoretic migration and molecular imprinting. For an understanding of the molecular recognition of MIP in CEC, a monolithic MIP in a capillary with 1,1'-binaphthyl-2,2'-diamine (BNA) imprinting was prepared by in situ copolymerization of imprinted molecule, methacrylic acid and ethylene glycol dimethacrylate in porogenic solvent, a mixture of toluene-isooctane. Strong recognition ability and high column performance (theory plates was 43,000 plates/m) of BNA were achieved on this monolithic MIP in CEC mode. In addition, BNA and its structural analogue, 1,1'-bi-2, 2'-naphthol, differing in functional groups, were used as model compounds to study imprinting effect on the resultant BNA-imprinted monolithic column, a reference column without imprinting of BNA and a open capillary. The effects of organic modifier concentration, pH value of buffer, salt concentration of buffer and column temperature on the retention and recognition of two compounds were investigated. The results showed that the molecular recognition on MIP monolith in CEC mode mainly derived from imprinting cavities on BNA-imprinted polymer other than chromatographic retention and electrophoretic migration.

  18. Capillary electrophoretic analysis reveals subcellular binding between individual mitochondria and cytoskeleton

    PubMed Central

    Kostal, Vratislav; Arriaga, Edgar A.

    2011-01-01

    Interactions between the cytoskeleton and mitochondria are essential for normal cellular function. An assessment of such interactions is commonly based on bulk analysis of mitochondrial and cytoskeletal markers present in a given sample, which assumes complete binding between these two organelle types. Such measurements are biased because they rarely account for non-bound ‘free’ subcellular species. Here we report on the use of capillary electrophoresis with dual laser induced fluorescence detection (CE-LIF) to identify, classify, count and quantify properties of individual binding events of mitochondria and cytoskeleton. Mitochondria were fluorescently labeled with DsRed2 while F-actin, a major cytoskeletal component, was fluorescently labeled with Alexa488-phalloidin. In a typical subcellular fraction of L6 myoblasts, 79% of mitochondrial events did not have detectable levels of F-actin, while the rest had on average ~2 zeptomole F-actin, which theoretically represents a ~ 2.5-μm long network of actin filaments per event. Trypsin treatment of L6 subcellular fractions prior to analysis decreased the fraction of mitochondrial events with detectable levels of F-actin, which is expected from digestion of cytoskeletal proteins on the surface of mitochondria. The electrophoretic mobility distributions of the individual events were also used to further distinguish between cytoskeleton-bound from cytoskeleton-free mitochondrial events. The CE-LIF approach described here could be further developed to explore cytoskeleton interactions with other subcellular structures, the effects of cytoskeleton destabilizing drugs, and the progression of viral infections. PMID:21309532

  19. Automated enzyme-based diagonal capillary electrophoresis: application to phosphopeptide characterization

    PubMed Central

    Wojcik, Roza; Vannatta, Michael

    2010-01-01

    Diagonal capillary electrophoresis is a form of two-dimensional capillary electrophoresis that employs identical separation modes in each dimension. The distal end of the first capillary incorporates an enzyme-based microreactor. Analytes that are not modified by the reactor will have identical migration times in the two capillaries and will generate spots that fall on the diagonal in a reconstructed two-dimensional electropherogram. Analytes that undergo enzymatic modification in the reactor will have a different migration time in the second capillary and will generate spots that fall off the diagonal in the electropherogram. We demonstrate the system with immobilized alkaline phosphatase to monitor the phosphorylation status of a mixture of peptides. This enzyme-based diagonal capillary electrophoresis assay appears to be generalizable; any post-translational modification can be detected as long as an immobilized enzyme is available that reacts with the modification under electrophoretic conditions. PMID:20099889

  20. Development and validation of a stability-indicating capillary zone electrophoretic method for the assessment of entecavir and its correlation with liquid chromatographic methods.

    PubMed

    Dalmora, Sergio Luiz; Nogueira, Daniele Rubert; D'Avila, Felipe Bianchini; Souto, Ricardo Bizogne; Leal, Diogo Paim

    2011-01-01

    A stability-indicating capillary zone electrophoresis (CZE) method was validated for the analysis of entecavir in pharmaceutical formulations, using nimesulide as an internal standard. A fused-silica capillary (50 µm i.d.; effective length, 40 cm) was used while being maintained at 25°C; the applied voltage was 25 kV. A background electrolyte solution consisted of a 20 mM sodium tetraborate solution at pH 10. Injections were performed using a pressure mode at 50 mbar for 5 s, with detection at 216 nm. The specificity and stability-indicating capability were proven through forced degradation studies, evaluating also the in vitro cytotoxicity test of the degraded products. The method was linear over the concentration range of 1-200 µg mL(-1) (r(2) = 0.9999), and was applied for the analysis of entecavir in tablet dosage forms. The results were correlated to those of validated conventional and fast LC methods, showing non-significant differences (p > 0.05).

  1. Quantitative analysis of synthetic dyes in lipstick by micellar electrokinetic capillary chromatography.

    PubMed

    Desiderio, C; Marra, C; Fanali, S

    1998-06-01

    The separation of synthetic dyes, used as color additives in cosmetics, by micellar electrokinetic capillary chromatography (MEKC) is described in this study. The separation of seven dyes, namely eosine, erythrosine, cyanosine, rhodamine B, orange II, chromotrope FB and tartrazine has been achieved in about 3 min in an untreated fused silica capillary containing as background electrolyte a 25 mM tetraborate/phosphate buffer, pH 8.0, and 30 mM sodium dodecyl sulfate. The electrophoretic method exhibits precision and relatively high sensitivity. A detection limit (LOD, signal/noise = 3) in the range of 5-7.5 X 10(-7) M of standard compounds was recorded. Intra-day repeatability of all the studied dye determinations (8 runs) gave the following results (limit values), % standard deviation: 0.24-1.54% for migration time, 0.99-1.24% for corrected peak areas, 0.99-1.24% for corrected peak area ratio (analyte/internal standard) and 1.56-2.74% for peak areas. The optimized method was successfully applied to the analysis of a lipstick sample where eosine and cyanosine were present.

  2. Continuous electrophoretic purification of individual analytes from multicomponent mixtures.

    PubMed

    McLaren, David G; Chen, David D Y

    2004-04-15

    Individual analytes can be isolated from multicomponent mixtures and collected in the outlet vial by carrying out electrophoretic purification through a capillary column. Desired analytes are allowed to migrate continuously through the column under the electric field while undesired analytes are confined to the inlet vial by application of a hydrodynamic counter pressure. Using pressure ramping and buffer replenishment techniques, 18% of the total amount present in a bulk sample can be purified when the resolution to the adjacent peak is approximately 3. With a higher resolution, the yield could be further improved. Additionally, by periodically introducing fresh buffer into the sample, changes in pH and conductivity can be mediated, allowing higher purity (>or=99.5%) to be preserved in the collected fractions. With an additional reversed cycle of flow counterbalanced capillary electrophoresis, any individual component in a sample mixture can be purified providing it can be separated in an electrophoresis system.

  3. Separation of saccharides derivatized with 2-aminobenzoic acid by capillary electrophoresis and their structural consideration by nuclear magnetic resonance.

    PubMed

    He, Liping; Sato, Kae; Abo, Mitsuru; Okubo, Akira; Yamazaki, Sunao

    2003-03-01

    Saccharides including mono- and disaccharides were quantitatively derivatized with 2-aminobenzoic acid (2-AA). These derivatives were then separated by capillary zone electrophoresis with UV detection using 50mM sodium phosphate buffer as the running electrolyte solution. In particular, the saccharide derivatives with the same molecular weight as 2-AA aldohexoses (mannose and glucose) and 2-AA aldopentoses (ribose and xylose) were well separated. The underlying reasons for separation were explored by studying their structural data using 1H and 13C NMR. It was found that the configurational difference between their hydroxyl group at C2 or C3 could cause the difference in Stokes' radii between their molecules and thus lead to different electrophoretic mobilities. The correlation between the electrophoretic behavior of these carbohydrate derivatives and their structures was studied utilizing the calculated molecular models of the 2-AA-labeled mannose, glucose, ribose, and xylose.

  4. Use of hydrophilic polymer coatings for control of electroosmosis and protein adsorption

    NASA Technical Reports Server (NTRS)

    Harris, J. Milton

    1987-01-01

    The purpose of this project was to examine the utility of polyethylene glycol (PEG) and dextran coatings for control of electroosmosis and protein adsorption; electroosmosis is an important, deleterious process affecting electrophoretic separations, and protein adsorption is a factor which needs to be controlled during protein crystal growth to avoid multiple nucleation sites. Performance of the project required use of X-ray photoelectron spectroscopy to refine previously developed synthetic methods. The results of this spectroscopic examination are reported. Measurements of electroosmotic mobility of charged particles in appropriately coated capillaries reveals that a new, one-step route to coating capillaries gives a surface in which electroosmosis is dramatically reduced. Similarly, both PEG and dextran coatings were shown by protein adsorption measurements to be highly effective at reducing protein adsorption on solid surfaces. These results should have impact on future low-g electrophoretic and protein crystal growth experiments.

  5. Electrohydrodynamic properties of succinoglycan as probed by fluorescence correlation spectroscopy, potentiometric titration and capillary electrophoresis.

    PubMed

    Duval, Jérôme F L; Slaveykova, Vera I; Hosse, Monika; Buffle, Jacques; Wilkinson, Kevin J

    2006-10-01

    The electrostatic, hydrodynamic and conformational properties of aqueous solutions of succinoglycan have been analyzed by fluorescence correlation spectroscopy (FCS), proton titration, and capillary electrophoresis (CE) over a large range of pH values and electrolyte (NaCl) concentrations. Using the theoretical formalism developed previously for the electrokinetic properties of soft, permeable particles, a quantitative analysis for the electro-hydrodynamics of succinoglycan is performed by taking into account, in a self-consistent manner, the measured values of the diffusion coefficients, electric charge densities, and electrophoretic mobilities. For that purpose, two limiting conformations for the polysaccharide in solution are tested, i.e. succinoglycan behaves as (i) a spherical, random coil polymer or (ii) a rodlike particle with charged lateral chains. The results show that satisfactory modeling of the titration data for ionic strengths larger than 50 mM can be accomplished using both geometries over the entire range of pH values. Electrophoretic mobilities measured for sufficiently large pH values (pH > 5-6) are in line with predictions based on either model. The best manner to discriminate between these two conceptual models is briefly discussed. For low pH values (pH < 5), both models indicate aggregation, resulting in an increase of the hydrodynamic permeability and a decrease of the diffusion coefficient.

  6. A capillary electrophoretic method for fingerprinting low molecular weight heparins.

    PubMed

    King, J Timothy; Desai, Umesh R

    2008-09-15

    Clinically used low molecular weight heparins (LMWH) are anticoagulants of choice and are phenomenally complex mixtures of millions of distinct natural and unnatural polymeric sequences. The FDA recommends that each LMWH be considered as an independent drug with its own activity profile, placing significant importance on the biophysical characterization of each intact LMWH. We report a robust protocol for fingerprinting these pharmaceutical agents. Capillary electrophoresis of three LMWHs, enoxaparin, tinzaparin, and a Sigma preparation, under reverse polarity conditions in the presence of selected linear alkyl polyamines gives an electrophoretic pattern that is characteristic of the nature of the starting material. The buffers that best provided optimal resolution without compromising sensitivity and speed of analysis were 50 mM sodium phosphate, pH 2.3, and 100 mM ammonium formate, pH 3.5. Resolution was strongly dependent on the structure of polyamine with pentaethylenehexamine being most effective for enoxaparin and Sigma LMWH. In contrast, tinzaparin could be best resolved with tetraethylenepentamine. Cyclic polyamines were ineffective. Resolution was also dependent on the concentration of resolving agents and displayed a narrow window that provides optimal resolution. These features suggest a strong structural origin of the fingerprint pattern. Overall, the simple protocol will find special use in assessing LMWH quality and batch-to-batch variability.

  7. Development and validation of an analytical method for the separation and determination of major bioactive curcuminoids in Curcuma longa rhizomes and herbal products using non-aqueous capillary electrophoresis.

    PubMed

    Anubala, S; Sekar, R; Nagaiah, K

    2014-06-01

    A simple, fast and efficient non-aqueous capillary electrophoresis method (NACE) was developed for the simultaneous determination of three major bioactive curcuminoids (CMNs) in Curcuma longa rhizomes and its herbal products. Good separation, resolution and reproducibility were achieved with the background electrolyte (BGE) consisting a mixture of 15.0 mM sodium tetraborate and 7.4 mM sodium hydroxide (NaOH) in 2:10:15 (v/v/v) of water, 1-propanol, and methanol. The influences of background electrolyte, sodium hydroxide, water, sodium dodecyl sulfate and hydroxylpropyl-β-cyclodextrin on separations were investigated. The separation was carried out in a fused-silica capillary tube with reverse polarity. Hydrodynamic injection of 25mbar for 12s was used for injecting samples and a voltage of 28 kV was applied for separation. The ultrasonication method was used for the extraction of CMNs from the turmeric herbal products and the extract was filtered and directly injected without any further treatments. The limits of detection and quantification were less than 5.0 and 14.6 µg/ml respectively for all CMNs. The percentage recoveries for CMNs were >97.2% (%RSD, <2.62). The results obtained by the method were compared with existing spectrophotometric and HPLC methods. The related compounds in the extract did not interfere in the determination of CMNs. The proposed NACE method is better than existing chromatographic and electrophoretic methods in terms of simple electrophoretic medium, fast analysis and good resolution. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. DNA migration mechanism analyses for applications in capillary and microchip electrophoresis

    PubMed Central

    Forster, Ryan E.; Hert, Daniel G.; Chiesl, Thomas N.; Fredlake, Christopher P.; Barron, Annelise E.

    2009-01-01

    In 2009, electrophoretically driven DNA separations in slab gels and capillaries have the sepia tones of an old-fashioned technology in the eyes of many, even while they remain ubiquitously used, fill a unique niche, and arguably have yet to reach their full potential. For comic relief, what is old becomes new again: agarose slab gel separations are used to prepare DNA samples for “next-gen” sequencing platforms (e.g., the Illumina and 454 machines)—dsDNA molecules within a certain size range are “cut out” of a gel and recovered for subsequent “massively parallel” pyrosequencing. In this review, we give a Barron lab perspective on how our comprehension of DNA migration mechanisms in electrophoresis has evolved, since the first reports of DNA separations by CE (∼1989) until now, 20 years later. Fused silica capillaries, and borosilicate glass and plastic microchips, quietly offer increasing capacities for fast (and even “ultra-fast”), efficient DNA separations. While the channel-by-channel scaling of both old and new electrophoresis platforms provides key flexibility, it requires each unique DNA sample to be prepared in its own micro- or nanovolume. This Achille's heel of electrophoresis technologies left an opening through which pooled-sample, next-gen DNA sequencing technologies rushed. We shall see, over time, whether sharpening understanding of transitions in DNA migration modes in crosslinked gels, nanogel solutions, and uncrosslinked polymer solutions will allow electrophoretic DNA analysis technologies to flower again. Microchannel electrophoresis, after a quiet period of metamorphosis, may emerge sleeker and more powerful, to claim its own important niche applications. PMID:19582705

  9. Electrophoretic analysis of cyanide depletion by Pseudomonas alcaligenes.

    PubMed

    Zaugg, S E; Davidson, R A; Walker, J C; Walker, E B

    1997-02-01

    Bacterial-facilitated depletion of cyanide is under development for remediation of heap leach operations in the gold mining industry. Capillary electrophoresis was found to be a powerful tool for quantifying cyanide depletion. Changes in cyanide concentration in aqueous suspensions of Pseudomonas alcaligenes bacteria and cyanide at elevated pH were easily monitored by capillary electrophoresis. The resulting data can be used to study rates of cyanide depletion by this strain of bacteria. Concentrations of these bacteria at 10(5) cells/mL were found to reduce cyanide from 100 ppm to less than 8 ppm in four days. In addition, other ions of interest in cyanide metabolism, such as formate, can be simultaneously analyzed. Direct UV detection of cyanide at 192 nm further simplifies the analytical method for these ions.

  10. Electrophoresis-mass spectrometry probe

    DOEpatents

    Andresen, Brian D.; Fought, Eric R.

    1987-01-01

    The invention involves a new technique for the separation of complex mixtures of chemicals, which utilizes a unique interface probe for conventional mass spectrometers which allows the electrophoretically separated compounds to be analyzed in real-time by a mass spectrometer. This new chemical analysis interface, which couples electrophoresis with mass spectrometry, allows complex mixtures to be analyzed very rapidly, with much greater specificity, and with greater sensitivity. The interface or probe provides a means whereby large and/or polar molecules in complex mixtures to be completely characterized. The preferred embodiment of the probe utilizes a double capillary tip which allows the probe tip to be continually wetted by the buffer, which provides for increased heat dissipation, and results in a continually operating interface which is more durable and electronically stable than the illustrated single capillary tip probe interface.

  11. Non-aqueous capillary electrophoretic separation of cholesterol and 25-hydroxycholesterol after derivatization with Girard P reagent.

    PubMed

    Gregus, Michal; Roberg-Larsen, Hanne; Lundanes, Elsa; Foret, Frantisek; Kuban, Petr; Wilson, Steven Ray

    2017-10-01

    Capillary electrophoresis (CE) can provide high separation efficiency with very simple instrumentation, but has yet to be explored regarding oxysterols/cholesterol. Cholesterol and 25-hydroxycholesterol (both are 4-ene-3-ketosteroids) were quantitatively transformed into hydrazones using Girard P reagent after enzymatic oxidation by cholesterol oxidase. Separation was achieved using non-aqueous capillary electrophoresis with UV detection at 280nm; the "charge-tagging" Girard P reagent ensured both charge and chromophore (which are requirements for CE-UV). Excess reagent was also separated from the two analytes, eliminating the need for removal prior to the analysis. The compounds were separated in less than 5min with excellent separation efficiency, using separation electrolytes fully compatible with mass spectrometry. The CE-UV method was used to optimize steps for charge-tagging, revealing that the procedure is affected by the analyte/reagent ratio and reaction time, but also the analyte structure. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thornton, Michelle

    Capillary electrophoresis (CE) is an effective method for separating ionic species according to differences in their electrophoretic mobilities. CE separations of amino acids by direct detection are difficult due to their similar electrophoretic mobilities and low absorbances. However, native amino acids can be separated by CE as cations at a low pH by adding an alkanesulfonic acid to the electrolyte carrier which imparts selectivity to the system. Derivatization is unnecessary when direct UV detection is used at 185 nm. Simultaneous speciation of metal cations such as vanadium (IV) and vanadium (V) can easily be performed without complexation prior to analysis.more » An indirect UV detection scheme for acidic conditions was also developed using guanidine as the background carrier electrolyte (BCE) for the indirect detection of metal cations. Three chapters have been removed for separate processing. This report contains introductory material, references, and general conclusions. 80 refs.« less

  13. Capillary electrophoretic analysis of flavonoids in single-styled hawthorn (Crataegus monogyna Jacq.) ethanolic extracts.

    PubMed

    Urbonaviciūte, A; Jakstas, V; Kornysova, O; Janulis, V; Maruska, A

    2006-04-21

    Flavonoids are an important group of natural compounds, which can prevent coronary heart disease and have antioxidant properties. Hawthorn is a well known and widely used medicinal plant due to its cardiotonic activity. Previous studies refer mostly to the HPLC analysis of the flavonoids: vitexin, quercetin, hyperoside, oligomeric procyanidins, which appear to be primarily responsible for the cardiac action of the plant. Aqueous ethanolic extracts of single-styled hawthorn (Crataegus monogyna Jacq., f.: Rosaceae Juss.) leaves and sprouts were analyzed by means of capillary zone electrophoresis (CZE). Influence of vegetation period on the extract qualitative composition and flavonoids quantities was evaluated. Sample preparation by extraction using different concentration of aqueous ethanol (40-96%, v/v) and the influence of extractant composition on the recovery of flavonoids are discussed in detail. The results obtained using CZE are compared to the results of spectrophotometric and HPLC analysis of the extracts. The effect of storage conditions of extracts (solar irradiation, temperature and duration) on degradation of flavonoids was investigated.

  14. Characterizing the interaction between enantiomers of eight psychoactive drugs and highly sulfated-β-cyclodextrin by counter-current capillary electrophoresis.

    PubMed

    Asensi-Bernardi, Lucía; Escuder-Gilabert, Laura; Martín-Biosca, Yolanda; Sagrado, Salvador; Medina-Hernández, María José

    2014-01-01

    The estimation of apparent binding constants and limit mobilities of the complexes of the enantiomers that characterize the interaction of enantiomers with chiral selectors, in this case highly sulfated β-cyclodextrin, was approached using a simple and economic electrophoretic modality, the complete filling technique (CFT) in counter-current mode. The enantiomers of eight psychoactive drugs, four antihistamines (dimethindene, promethazine, orphenadrine and terfenadine) and four antidepressants (bupropion, fluoxetine, nomifensine and viloxazine) were separated for the first time for this cyclodextrin (CD). Estimations of thermodynamic and electrophoretic enantioselectivies were also performed. Results indicate that, in general, thermodynamic enantioselectivity is the main component explaining the high resolution found, but also one case suggests that electrophoretic enantioselectivity itself is enough to obtain a satisfactory resolution. CFT results advantageous compared with conventional capillary electrophoresis (CE) and partial filling technique (PFT) for the study of the interaction between drugs and chiral selectors. It combines the use of a simple fitting model (as in CE), when the enantiomers do not exit the chiral selector plug during the separation (i.e. mobility of electroosmotic flow larger than mobility of CD), and drastic reduction of the consumption (and cost; ~99.7%) of the CD reagent (as in PFT) compared with the conventional CE. Copyright © 2013 John Wiley & Sons, Ltd.

  15. Control of electroosmosis in coated quartz capillaries

    NASA Technical Reports Server (NTRS)

    Herren, Blair J.; Van Alstine, James; Snyder, Robert S.; Shafer, Steven G.; Harris, J. Milton

    1987-01-01

    The effectiveness of various coatings for controlling the electroosmotic fluid flow that hinders electrophoretic processes is studied using analytical particle microelectrophoresis. The mobilities of 2-micron diameter glass and polystyrene latex spheres (exhibiting both negative and zero effective surface charge) were measured in 2-mm diameter quartz capillaries filled with NaCl solutions within the 3.5-7.8 pH range. It is found that capillary inner surface coatings using 5000 molecular weight (or higher) poly(ethylene glycol): significantly reduced electroosmosis within the selected pH range, were stable for long time periods, and appeared to be more effective than dextran, methylcellulose, or silane coatings.

  16. Affinity capillary electrophoresis for studying interactions in life sciences.

    PubMed

    Olabi, Mais; Stein, Matthias; Wätzig, Hermann

    2018-05-10

    Affinity capillary electrophoresis (ACE) analyzes noncovalent interactions between ligands and analytes based on changes in their electrophoretic mobility. This technique has been widely used to investigate various biomolecules, mainly proteins, polysaccharides and hormones. ACE is becoming a technique of choice to validate high throughput screening results, since it is very predictively working in realistic and relevant media, e.g. in body fluids. It is highly recommended to incorporate ACE as a powerful analytical tool to properly prepare animal testing and preclinical studies. The interacting molecules can be found free in solution or can be immobilized to a solid support. Thus, ACE is classified in two modes, free solution ACE and immobilized ACE. Every ACE mode has advantages and disadvantages. Each can be used for a variety of applications. This review covers literature of scopus and SciFinder data base in the period from 2016 until beginning 2018, including the keywords "affinity capillary electrophoresis", "immunoaffinity capillary electrophoresis", "immunoassay capillary electrophoresis" and "immunosorbent capillary electrophoresis". More than 200 articles have been found and 112 have been selected and thoroughly discussed. During this period, the data processing and the underlying calculations in mobility shift ACE (ms ACE), frontal analysis ACE (FA ACE) and plug-plug kinetic capillary electrophoresis (ppKCE) as mostly applied free solution techniques have substantially improved. The range of applications in diverse free solution and immobilized ACE techniques has been considerably broadened. Copyright © 2018. Published by Elsevier Inc.

  17. Simple semi-automated portable capillary electrophoresis instrument with contactless conductivity detection for the determination of β-agonists in pharmaceutical and pig-feed samples.

    PubMed

    Nguyen, Thi Anh Huong; Pham, Thi Ngoc Mai; Doan, Thi Tuoi; Ta, Thi Thao; Sáiz, Jorge; Nguyen, Thi Quynh Hoa; Hauser, Peter C; Mai, Thanh Duc

    2014-09-19

    An inexpensive, robust and easy to use portable capillary electrophoresis instrument with miniaturized high-voltage capacitively coupled contactless conductivity detection was developed. The system utilizes pneumatic operation to manipulate the solutions for all flushing steps. The different operations, i.e. capillary flushing, interface rinsing, and electrophoretic separation, are easily activated by turning an electronic switch. To allow the analysis of samples with limited available volume, and to render the construction less complicated compared to a computer-controlled counterpart, sample injection is carried out hydrodynamically directly from the sample vial into the capillary by manual syphoning. The system is a well performing solution where the financial means for the highly expensive commercial instruments are not available and where the in-house construction of a sophisticated automated instrument is not possible due to limited mechanical and electronic workshop facilities and software programming expertise. For demonstration, the system was employed successfully for the determination of some β-agonists, namely salbutamol, metoprolol and ractopamine down to 0.7ppm in pharmaceutical and pig-feed sample matrices in Vietnam. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Analysis of optical purity and impurity of synthetic D-phenylalanine products using sulfated beta-cyclodextrin as chiral selector by reversed-polarity capillary electrophoresis.

    PubMed

    Zhao, Yan; Yang, Xing-Bin; Jiang, Ru; Sun, Xiao-Li; Li, Xiao-Ye; Liu, Wen-Min; Zhang, Sheng-Yong

    2006-02-01

    A new capillary electrophoresis (CE) method has been achieved for simultaneous separation and quantification of phenylalanine, N-acetylphenylalanine enantiomers, and prochiral N-acetylaminocinnamic acid, possibly co-existent in reaction systems or synthesized products of D-phenylalanine. The separation was carried out in an uncoated capillary under reversed-electrophoretic mode. Among the diverse charged cyclodextrins (CDs) examined, highly sulfated (HS)-beta-CD as the chiral selector exhibited the best enantioselectivity. The complete separation of the analytes was obtained under the optimum conditions of pH 2.5, 35 mM Tris buffer containing 4% HS-beta-CD, applied voltage -15 kV, and capillary temperature 25 degrees C. Furthermore, the proposed method was applied to the determination of optical purity and trace impurities in three batches of the asymmetric synthetic samples of D-phenylalanine, and satisfactory results were obtained. The determination recoveries of the samples were in the range of 97.8-103.8%, and precisions fell within 2.3-5.0% (RSD). The results demonstrate that this CE method is a useful, simple technique and is applicable to purity assays of D-phenylalanine. (c) 2005 Wiley-Liss, Inc.

  19. Electrophoresis-mass spectrometry probe

    DOEpatents

    Andresen, B.D.; Fought, E.R.

    1987-11-10

    The invention involves a new technique for the separation of complex mixtures of chemicals, which utilizes a unique interface probe for conventional mass spectrometers which allows the electrophoretically separated compounds to be analyzed in real-time by a mass spectrometer. This new chemical analysis interface, which couples electrophoresis with mass spectrometry, allows complex mixtures to be analyzed very rapidly, with much greater specificity, and with greater sensitivity. The interface or probe provides a means whereby large and/or polar molecules in complex mixtures to be completely characterized. The preferred embodiment of the probe utilizes a double capillary tip which allows the probe tip to be continually wetted by the buffer, which provides for increased heat dissipation, and results in a continually operating interface which is more durable and electronically stable than the illustrated single capillary tip probe interface. 8 figs.

  20. Mobility-based correction for accurate determination of binding constants by capillary electrophoresis-frontal analysis.

    PubMed

    Qian, Cheng; Kovalchik, Kevin A; MacLennan, Matthew S; Huang, Xiaohua; Chen, David D Y

    2017-06-01

    Capillary electrophoresis frontal analysis (CE-FA) can be used to determine binding affinity of molecular interactions. However, its current data processing method mandate specific requirement on the mobilities of the binding pair in order to obtain accurate binding constants. This work shows that significant errors are resulted when the mobilities of the interacting species do not meet these requirements. Therefore, the applicability of CE-FA in many real word applications becomes questionable. An electrophoretic mobility-based correction method is developed in this work based on the flux of each species. A simulation program and a pair of model compounds are used to verify the new equations and evaluate the effectiveness of this method. Ibuprofen and hydroxypropyl-β-cyclodextrinare used to demonstrate the differences in the obtained binding constant by CE-FA when different calculation methods are used, and the results are compared with those obtained by affinity capillary electrophoresis (ACE). The results suggest that CE-FA, with the mobility-based correction method, can be a generally applicable method for a much wider range of applications. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Capillary electrophoresis of chitooligosaccharides in acidic solution: simple determination using a quaternary-ammonium-modified column and indirect photometric detection with crystal violet.

    PubMed

    Hattori, Toshiaki; Anraku, Nobuhiro; Kato, Ryo

    2010-02-01

    Five chitosan oligosaccharides were separated in acidic aqueous solution by capillary electrophoresis (CE) with indirect photometric detection using a positively coated capillary. Electrophoretic mobility of the chitooligosaccharides (COSs) depended on the number of monomer units in acidic aqueous solution, similar to other polyelectrolyte oligomers. The separation was developed in nitric acid aqueous solution at pH 3.0 with 1 mM Crystal Violet, using a capillary positively coated with N-trimethoxypropyl-N,N,N-trimethylammonium chloride. The limit of the detection for chitooligosaccharides with two to six saccharide chains was less than 5 microM. CE determination of an enzymatically hydrolyzed COS agreed with results from HPLC. 2009 Elsevier B.V. All rights reserved.

  2. Chitosan as cationic polyelectrolyte for the modification of electroosmotic flow and its utilization for the separation of inorganic anions by capillary zone electrophoresis.

    PubMed

    Takayanagi, Toshio; Motomizu, Shoji

    2006-09-01

    Cationic polyelectrolyte of chitosan was used for the reversal of electroosmotic flow in capillary zone electrophoresis. The chitosan was dissolved in acetic acid solution, and stable electroosmotic flow was obtained at the chitosan concentrations between 50 and 300 microg/mL. Separation of inorganic anions was carried out using the dynamically coated capillary by capillary zone electrophoresis. Nine kinds of anions were separated and detected with the capillary. The electrophoretic mobility of the analyte anions decreased with increasing concentrations of chitosan in the migrating solution through ion-ion interaction, but the migration order of the analyte anions was not changed in the concentration range of the chitosan examined. The signal shape for the analyte anions was developed by using field-enhanced sample stacking with 10 mM sodium sulfate.

  3. Chiral analysis of UV nonabsorbing compounds by capillary electrophoresis using macrocyclic antibiotics: 1. Separation of aspartic and glutamic acid enantiomers.

    PubMed

    Bednar, P; Aturki, Z; Stransky, Z; Fanali, S

    2001-07-01

    Glycopeptide antibiotics, namely vancomycin or teicoplanin, were evaluated in capillary electrophoresis for the analysis of UV nonabsorbing compounds such as aspartic and glutamic acid enantiomers. Electrophoretic runs were performed in laboratory-made polyacrylamide-coated capillaries using the partial filling-counter current method in order to avoid the presence on the detector path of the absorbing chiral selector. The background electrolyte consisted of an aqueous or aqueous-organic buffer in the pH range of 4.5-6.5 of sorbic acid/histidine and the appropriate concentration of chiral selector. Several experimental parameters such as antibiotic concentration and type, buffer pH, organic modifier, type and concentration of absorbing co-ion (for the indirect UV detection) were studied in order to find the optimum conditions for the chiral resolution of the two underivatized amino acids in their enantiomers. Among the two investigated chiral selectors, vancomycin resulted to be the most useful chiral selector allowing relatively high chiral resolution of the studied compounds even at low concentration. The optimized method (10 mM sorbic acid/histidine, pH 5, and 10 mM of vancomycin) was used for the analysis of real samples such as teeth dentine and beer.

  4. Electrphoretic Sample Excitation Light Assembly.

    DOEpatents

    Li, Qingbo; Liu, Changsheng

    2002-04-02

    An automated electrophoretic system is disclosed. The system employs a capillary cartridge having a plurality of capillary tubes. The cartridge has a first array of capillary ends projecting from one side of a plate. The first array of capillary ends are spaced apart in substantially the same manner as the wells of a microtitre tray of standard size. This allows one to simultaneously perform capillary electrophoresis on samples present in each of the wells of the tray. The system includes a stacked, dual carrousel arrangement to eliminate cross-contamination resulting from reuse of the same buffer tray on consecutive executions from electrophoresis. The system also has a gel delivery module containing a gel syringe/a stepper motor or a high pressure chamber with a pump to quickly and uniformly deliver gel through the capillary tubes. The system further includes a multi-wavelength beam generator to generate a laser beam which produces a beam with a wide range of wavelengths. An off-line capillary reconditioner thoroughly cleans a capillary cartridge to enable simultaneous execution of electrophoresis with another capillary cartridge. The streamlined nature of the off-line capillary reconditioner offers the advantage of increased system throughput with a minimal increase in system cost.

  5. Motorized Positioning Apparatus Having Coaxial Carrousels.

    DOEpatents

    Li, Qingbo; Kane, Thomas E.; Liu, Changsheng; Sonnenschein, Bernard; Sharer, Michael V.; Kernan, John R.

    2002-04-02

    An automated electrophoretic system is disclosed. The system employs a capillary cartridge having a plurality of capillary tubes. The cartridge has a first array of capillary ends projecting from one side of a plate. The first array of capillary ends are spaced apart in substantially the same manner as the wells of a microtitre tray of standard size. This allows one to simultaneously perform capillary electrophoresis on samples present in each of the wells of the tray. The system includes a stacked, dual carrousel arrangement to eliminate cross-contamination resulting from reuse of the same buffer tray on consecutive executions from electrophoresis. The system also has a gel delivery module containing a gel syringe/a stepper motor or a high pressure chamber with a pump to quickly and uniformly deliver gel through the capillary tubes. The system further includes a multi-wavelength beam generator to generate a laser beam which produces a beam with a wide range of wavelengths. An off-line capillary reconditioner thoroughly cleans a capillary cartridge to enable simultaneous execution of electrophoresis with another capillary cartridge. The streamlined nature of the off-line capillary reconditioner offers the advantage of increased system throughput with a minimal increase in system cost.

  6. Fluid mechanics of electroosmotic flow and its effect on band broadening in capillary electrophoresis.

    PubMed

    Ghosal, Sandip

    2004-01-01

    Electroosmotic flow (EOF) usually accompanies electrophoretic migration of charged species in capillary electrophoresis unless special precautions are taken to suppress it. The presence of the EOF provides certain advantages in separations. It is an alternative to mechanical pumps, which are inefficient and difficult to build at small scales, for transporting reagents and analytes on microfluidic chips. The downside is that any imperfection that distorts the EOF profile reduces the separation efficiency. In this paper, the basic facts about EOF are reviewed from the perspective of fluid mechanics and its effect on separations in free solution capillary zone electrophoresis is discussed in the light of recent advances.

  7. Fast and simultaneous detection of prominent natural antioxidants using analytical microsystems for capillary electrophoresis with a glassy carbon electrode: a new gateway to food environments.

    PubMed

    Blasco, Antonio Javier; Barrigas, Inés; González, María Cristina; Escarpa, Alberto

    2005-12-01

    This paper examines for the first time the analytical possibilities of fast and simultaneous detection of prominent natural antioxidants including examples of flavonoids and vitamins using a CE microchip with electrochemical detection (ED). Unpinched injection conditions, zone electrophoretic separation and amperometric detection were carefully assayed and optimised. Analysis involved the zone electrophoretic separation of arbutin, (+)-catechin and ascorbic acid in less than 4 min using a borate buffer (pH 9.0, 50 mM), employing 2 kV as the separation voltage and +1.0 V as the detection potential. In addition, the separation of different 'couples' of natural antioxidants of food significance including (+)-catechin and ascorbic acid, (+)-catechin and rutin, as well as arbutin and phlorizdin is proposed. To demonstrate the potential and future role of CE microsystems, analytical possibilities and a new route in the raw sample analysis are presented. The preliminary results obtained allow the proposal of CE-ED microchips as a real gateway to microanalysis in foods.

  8. Analysis of diterpenoic compounds in natural resins applied as binders in museum objects by capillary electrophoresis.

    PubMed

    Findeisen, Anna; Kolivoska, Viliam; Kaml, Isabella; Baatz, Wolfgang; Kenndler, Ernst

    2007-07-20

    The exudates of conifers consist mainly of diterpenoic acids of the abietane and pimarane type (abietic, neoabietic, dehydroabietic, palustric, pimaric, isopimaric, levopimaric and sandaracopimaric acid) and larixol acetate. These natural resins were used as adhesives, coatings, varnishes or plasticizers in artistic and historic works since ancient times. For the purpose of conservation and restoration and for art historic examination of such museum objects the identification of the binding media used is undoubtedly of paramount importance. In the present paper, the characterization of these resins based on the pattern of their diterpenoid constituents is carried out by capillary electrophoresis. For separation a background electrolyte which has been initially introduced for the analysis of chlorinated and natural resin acids in waste water was modified and the experimental conditions were adjusted in terms of resolution and analysis time. Separation was carried out in borate buffer at pH 9.25 (ionic strength 20 mmol L(-1)) with methyl-beta-cyclodextrin and sulfobutylether-beta-cyclodextrin as additives to increase selectivity and enhance the solubility of the analytes. With this electrophoretic system the resin acids of interest and larixol acetate--all as anionic cyclodextrin complexes--were separated within 5 min and detected at 200, 250 and 270 nm with a diode array detector. The electrophoretic patterns served for the characterisation of the relevant diterpenoic resins, balsams and copals. Sample pre-treatment was limited to sonication in methanol at 55 degrees C for 30 min. This enables the identification of the resins in mixtures with other binders like plant gums, animal glues or drying oils, even when these media are present in excess. Colophony was identified as resinous constituent of a modelling mass for gilded frames originating from the 19th century.

  9. Carbon nanotube/poly(ethylene-co-vinyl acetate) composite electrode for capillary electrophoretic determination of esculin and esculetin in Cortex Fraxini.

    PubMed

    Chen, Zhi; Zhang, Luyan; Chen, Gang

    2009-10-01

    In this report, a novel carbon nanotube/poly(ethylene-co-vinyl acetate) (CNT/EVA) composite electrode was developed for the amperometric detection in CE. The composite electrode was fabricated by packing a mixture of CNTs and melted EVA in a piece of fused-silica capillary under heat. It was coupled with CE for the separation and detection of esculin and esculetin in Cortex Fraxini, a traditional Chinese medicine, to demonstrate its feasibility and performance. Esculin and esculetin have been well separated within 9 min in a 40 cm long capillary at a separation voltage of 12 kV using a 50 mM borate buffer (pH 9.2). The new CNT-based CE detector offered significantly lower detection potentials, yielded enhanced S/N characteristics, and exhibited high resistance to surface fouling and enhanced stability. It showed long-term stability and reproducibility with relative standard deviations of less than 5% for the peak current (n=15) and should also find a wide range of applications in other microfluidic analysis systems.

  10. Quality control of benserazide-levodopa and carbidopa-levodopa tablets by capillary zone electrophoresis.

    PubMed

    Fanali, S; Pucci, V; Sabbioni, C; Raggi, M A

    2000-07-01

    In modern practice, the treatment of Parkinson's disease and syndrome is carried out using pharmaceutical formulations containing a combination of levodopa and a decarboxylation inhibitor (carbidopa or benserazide). Two pharmaceutical formulations were quantified by capillary zone electrophoresis using two procedures which differed only in the kind of background electrolyte used. One procedure used a 25 mM phosphate buffer, pH 2.5, while the second one used a 25 mM borate buffer, pH 8.5. The electrophoretic analysis was carried out using an uncoated fused- silica capillary, a separation voltage of 20 kV with currents typically less than 60 microA, and spectrophotometric detection at 205 nm. Calibration curves were performed for levodopa (concentration range 1-100 microg/mL), for carbidopa and benserazide (1-50 microg/mL), and the plots of the peak area versus concentration were found to be linear with a correlation coefficient better than 0.9990. Satisfactory results were obtained when commercial tablets were analyzed in terms of accuracy (98-102%), repeatability (0.6-2.0%), and intermediate precision (1.1-2.6%).

  11. Capillary Electrophoretic Technologies for Single Cell Metabolomics

    ERIC Educational Resources Information Center

    Lapainis, Theodore E.

    2009-01-01

    Understanding the functioning of the brain is hindered by a lack of knowledge of the full complement of neurotransmitters and neuromodulatory compounds. Single cell measurements aid in the discovery of neurotransmitters used by small subsets of neurons that would be diluted below detection limits or masked by ubiquitous compounds when working with…

  12. [Improvement of reproducibility in capillary electrophoretic characterization of rhubarb by normalization of migration time].

    PubMed

    Zhang, Hongyi; Ge, Lijuan; Chen, Hui; Jing, Cong; Shi, Zhihong

    2009-07-01

    The principle of the normalization of migration time and its application on the traditional Chinese medicine (TCM) analysis by capillary electrophoresis (CE) are presented. It is the core of the normalization of migration time that the fluctuation of apparent migration velocity for each component at different runs is attributed to the difference of electroosmotic flow velocity. To transform migration time (t) to normalized migration time, one peak or two peaks in the original electropherogram are selected as internal peak. The normalization of migration time is therefore classified into two types based on the number of selected internal peaks, one-peak and two-peak approaches. The migration times processed by one-peak normalization and by two-peak normalization are conducted by the following equations, respectively: (t'(i))(j) = 1/ [1/(t(i))(j) - [1/(t(istd))(j) - 1/(t(istd))1

  13. Detection of Hemoglobin New York [β113 (G15) Val→Glu, GTG>GAG] in a Thai Woman by Capillary Electrophoresis.

    PubMed

    Panyasai, Sitthichai; Pornprasert, Sakorn

    2016-12-01

    Hemoglobin (Hb) New York [β113 (G15) Val→Glu, GTG>GAG] is a very rare β-chain variant found in Thailand. This variant is often missed by routine laboratory testing because Hb New York and Hb A have the identical retention time on high performance liquid chromatography. We reported here for the first time that the detection of Hb New York in a Thai woman by using capillary electrophoresis (CE). A peak of Hb New York located ahead of Hb A at the electrophoretic zone 11 with a level of 42.8 %. The DNA sequencing revealed the GTG>GAG mutation at codon 113 for Hb New York on one allele of β-globin gene. Therefore, the CE has a high efficiency to prevent the misinterpretation of hemoglobin analysis in patients who are heterozygote of this variant.

  14. Determination of thermodynamic values of acidic dissociation constants and complexation constants of profens and their utilization for optimization of separation conditions by Simul 5 Complex.

    PubMed

    Riesová, Martina; Svobodová, Jana; Ušelová, Kateřina; Tošner, Zdeněk; Zusková, Iva; Gaš, Bohuslav

    2014-10-17

    In this paper we determine acid dissociation constants, limiting ionic mobilities, complexation constants with β-cyclodextrin or heptakis(2,3,6-tri-O-methyl)-β-cyclodextrin, and mobilities of resulting complexes of profens, using capillary zone electrophoresis and affinity capillary electrophoresis. Complexation parameters are determined for both neutral and fully charged forms of profens and further corrected for actual ionic strength and variable viscosity in order to obtain thermodynamic values of complexation constants. The accuracy of obtained complexation parameters is verified by multidimensional nonlinear regression of affinity capillary electrophoretic data, which provides the acid dissociation and complexation parameters within one set of measurements, and by NMR technique. A good agreement among all discussed methods was obtained. Determined complexation parameters were used as input parameters for simulations of electrophoretic separation of profens by Simul 5 Complex. An excellent agreement of experimental and simulated results was achieved in terms of positions, shapes, and amplitudes of analyte peaks, confirming the applicability of Simul 5 Complex to complex systems, and accuracy of obtained physical-chemical constants. Simultaneously, we were able to demonstrate the influence of electromigration dispersion on the separation efficiency, which is not possible using the common theoretical approaches, and predict the electromigration order reversals of profen peaks. We have shown that determined acid dissociation and complexation parameters in combination with tool Simul 5 Complex software can be used for optimization of separation conditions in capillary electrophoresis. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Chiral ionic liquids in chromatographic and electrophoretic separations.

    PubMed

    Kapnissi-Christodoulou, Constantina P; Stavrou, Ioannis J; Mavroudi, Maria C

    2014-10-10

    This report provides an overview of the application of chiral ionic liquids (CILs) in separation technology, and particularly in capillary electrophoresis and both gas and liquid chromatography. There is a large number of CILs that have been synthesized and designed as chiral agents. However, only a few have successfully been applied in separation technology. Even though this application of CILs is still in its early stages, the scientific interest is increasing dramatically. This article is focused on the use of CILs as chiral selectors, background electrolyte additives, chiral ligands and chiral stationary phases in electrophoretic and chromatographic techniques. Different examples of CILs, which contain either a chiral cation, a chiral anion or both, are presented in this review article, and their major advantages along with their potential applications in chiral electrophoretic and chromatographic recognition are discussed. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Investigation of electrophoretic exclusion method for the concentration and differentiation of proteins.

    PubMed

    Meighan, Michelle M; Vasquez, Jared; Dziubcynski, Luke; Hews, Sarah; Hayes, Mark A

    2011-01-01

    This work presents a technique termed as "electrophoretic exclusion" that is capable of differentiation and concentration of proteins in bulk solution. In this method, a hydrodynamic flow is countered by the electrophoretic velocity to prevent a species from entering into a channel. The separation can be controlled by changing the flow rate or applied electric potential in order to exclude a certain species selectively while allowing others to pass through the capillary. The exclusion of various proteins is investigated using a flow-injection regime of the method. Concentration of myoglobin of up to 1200 times the background concentration in 60 s was demonstrated. Additionally, negatively charged myoglobin was separated from a solution containing negatively charged allophycocyanin. Cationic cytochrome c was also differentiated from a solution with allophycocyanin. The ability to differentially transport species in bulk solution enables parallel and serial separation modes not available with other separations schemes.

  17. Temperature-Modulated Array High-Performance Liquid Chromatography

    PubMed Central

    Premstaller, Andreas; Xiao, Wenzhong; Oberacher, Herbert; O'Keefe, Matthew; Stern, David; Willis, Thomas; Huber, Christian G.; Oefner, Peter J.

    2001-01-01

    Using novel monolithic poly(styrene-divinylbenzene) capillary columns with an internal diameter of 0.2 mm, we demonstrate for the first time the feasibility of constructing high-performance liquid chromatography arrays for the detection of mutations by heteroduplex analysis under partially denaturing conditions. In one embodiment, such an array can be used to analyze one sample simultaneously at different temperatures to maximize the detection of mutations in DNA fragments containing multiple discrete melting domains. Alternatively, one may inject different samples onto columns kept at the same effective temperature. Further improvements in throughput can be obtained by means of laser-induced fluorescence detection and the differential labeling of samples with up to four different fluorophores. Major advantages of monolithic capillary high-performance liquid chromatographic arrays over their capillary electrophoretic analogs are the chemical inertness of the poly(styrene-divinylbenzene) stationary phase, the physical robustness of the column bed due to its covalent linkage to the inner surface of the fused silica capillary, and the feasibility to modify the stationary phase thereby allowing the separation of compounds not only on the principle of size exclusion, but also adsorption, distribution, and ion exchange. Analyses times are on the order of a few minutes and turnaround time is extremely short as there is no need for the replenishment of the separation matrix between runs. PMID:11691859

  18. Evaluation of capillary zone electrophoresis for the quality control of complex biologic samples: Application to snake venoms.

    PubMed

    Kpaibe, André P S; Ben-Ameur, Randa; Coussot, Gaëlle; Ladner, Yoann; Montels, Jérôme; Ake, Michèle; Perrin, Catherine

    2017-08-01

    Snake venoms constitute a very promising resource for the development of new medicines. They are mainly composed of very complex peptide and protein mixtures, which composition may vary significantly from batch to batch. This latter consideration is a challenge for routine quality control (QC) in the pharmaceutical industry. In this paper, we report the use of capillary zone electrophoresis for the development of an analytical fingerprint methodology to assess the quality of snake venoms. The analytical fingerprint concept is being widely used for the QC of herbal drugs but rarely for venoms QC so far. CZE was chosen for its intrinsic efficiency in the separation of protein and peptide mixtures. The analytical fingerprint methodology was first developed and evaluated for a particular snake venom, Lachesis muta. Optimal analysis conditions required the use of PDADMAC capillary coating to avoid protein and peptide adsorption. Same analytical conditions were then applied to other snake venom species. Different electrophoretic profiles were obtained for each venom. Excellent repeatability and intermediate precision was observed for each batch. Analysis of different batches of the same species revealed inherent qualitative and quantitative composition variations of the venoms between individuals. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Simultaneous determination of rifabutin and human serum albumin in pharmaceutical formulations by capillary electrophoresis.

    PubMed

    Ermolenko, Yu; Anshakova, A; Osipova, N; Kamentsev, M; Maksimenko, O; Balabanyan, V; Gelperina, S

    Capillary zone electrophoresis (CZE) was used for determination of rifabutin (RFB), an anti-tuberculosis antibiotic drug, in various pharmaceutical formulations. Apart from that, simultaneous determination of RFB and human serum albumin (HSA) was performed. Electrophoretic behaviour of RFB was examined at various pH levels. CE conditions: a quartz capillary tube (internal diameter 75mm, effective length 50cm, total length 60cm), the capillary temperature was 25°С, the voltage applied to the capillary tube was +20kV, the UV detection wavelength was 214nm, hydrodynamic injection of the sample was performed at 30mbar for 5s, tetraborate buffer solution (0.01М, рН9.2). The obtained results are characterized by high efficiency (number of theoretical plates up to 260,000) and sufficient sensitivity (LOQ starting from 0.02μg/ml for RFB). The obtained data are in good accord with both HPLC results (for RFB) and spectrophotometry (for HSA). Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Improved separation and size characterization of gold nanoparticles through a novel capillary zone electrophoresis method using poly(sodium4-styrenesulfonate) as stabiliser and a stepwise field strength gradient.

    PubMed

    Ciriello, Rosanna; Iallorenzi, Pina Teresa; Laurita, Alessandro; Guerrieri, Antonio

    2017-03-01

    A novel capillary zone electrophoresis (CZE) method was developed for an improved separation and size characterization of pristine gold nanoparticles (AuNP) using uncoated fused-silica capillaries with UV-Vis detection at 520 nm. To avoid colloid aggregation and/or adsorption during runs, poly(sodium 4-styrenesulfonate) (PSS) was added (1%, w/v) in the running buffer (CAPS 10 mM, pH 11). This polyelectrolyte conferred an enhanced stabilization to AuNP, both steric and electrostatic, exalting at the same time their differences in electrophoretic mobility. Resolution was further and successfully improved through a stepwise field strength gradient by the application of 25 kV for the first 5 min and then 10 kV. Migration times varied linearly with particles diameters showing relative standard deviations better than 1% for daily experiments and 3% for interday experiments. A comparison with the size distribution obtained by transmission electron microscopy (TEM) allowed assessing that the electrophoretic profile can reasonably be considered as representative of the effective size heterogeneity of each colloid. Finally, the practical utility of the proposed method was demonstrated by measuring the core diameter of a gold colloid sample produced by chemical synthesis which was in good agreement with the value obtained by TEM measurements. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Polyvinylpyrrolidone-sodium dodecylsulfate complex is a family of pseudo-polyanions with different charge densities: Evidence from capillary electrophoresis, capillary viscosimetry and conductometry.

    PubMed

    Wu, Yefan; Chen, Jie; Fang, Yun; Zhu, Meng

    2016-10-01

    Accordance with the previously supposed polyelectrolyte-like behaviour of neutral polymer-anionic surfactant complexes, direct evidence for the formation of the pseudo-polyanions in polyvinylpyrrolidone (PVP)-sodium dodecylsulfate (SDS) solution is put forward in this paper by capillary electrophoresis (CE) experiments in assistance with capillary viscosimetry and conductometry. The contradictory phenomena of the absolute value of relative electrophoretic mobility (re) increasing while the ionization degree (α) decreasing with the increasing specific clusterization [Г] in aqueous PVP-SDS solution are explained by the finding that the PVP-SDS complex is eventually a family of PVP-SDS pseudo-polyanions with different charge densities. And it is found countercations playing an important role in the formation of the PVP-SDS pseudo-polyanions in virtue of bridge effect. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Combined electrophoresis-electrospray interface and method

    DOEpatents

    Smith, Richard D. [Richland, WA; Udseth, Harold R. [Richland, WA; Olivares, Jose A. [Los Alamos, NM

    1994-10-18

    A system and method for analyzing molecular constituents of a composition sample includes: forming a solution of the sample, separating the solution by capillary electrophoresis into an eluent of constituents longitudinally separated according to their relative electrophoretic mobilities, electrospraying the eluent to form a charged spray in which the molecular constituents have a temporal distribution; and detecting or collecting the separated constituents in accordance with the temporal distribution in the spray. A first high-voltage (e.g., 5-100 KVDC) is applied to the solution. The spray is charged by applying a second high voltage (e.g., .+-.2-8 KVDC) between the eluent at the capillary exit and a cathode spaced in front of the exit. A complete electrical circuit is formed by a conductor which directly contacts the eluent at the capillary exit, or by conduction through a sheath electrode discharged in an annular sheath flow about the capillary exit.

  3. Combined electrophoresis-electrospray interface and method

    DOEpatents

    Smith, R.D.; Udseth, H.R.; Olivares, J.A.

    1994-10-18

    A system and method for analyzing molecular constituents of a composition sample include: forming a solution of the sample, separating the solution by capillary electrophoresis into an eluent of constituents longitudinally separated according to their relative electrophoretic mobilities, electrospraying the eluent to form a charged spray in which the molecular constituents have a temporal distribution; and detecting or collecting the separated constituents in accordance with the temporal distribution in the spray. A first high-voltage (e.g., 5--100 kVDC) is applied to the solution. The spray is charged by applying a second high voltage (e.g.,{+-}2--8 kVDC) between the eluent at the capillary exit and a cathode spaced in front of the exit. A complete electrical circuit is formed by a conductor which directly contacts the eluent at the capillary exit, or by conduction through a sheath electrode discharged in an annular sheath flow about the capillary exit. 21 figs.

  4. Combined electrophoresis-electrospray interface and method

    DOEpatents

    Smith, R.P.; Udseth, H.R.; Olivares, J.A.

    1989-12-05

    A system and method for analyzing molecular constituents of a composition sample includes: forming a solution of the sample, separating the solution by capillary electrophoresis into an eluent of constituents longitudinally separated according to their relative electrophoretic mobilities, electrospraying the eluent to form a charged spray in which the molecular constituents have a temporal distribution; and detecting or collecting the separated constituents in accordance with the temporal distribution in the spray. A first high-voltage (e.g., 5--100 kVDC) is applied to the solution. The spray is charged by applying a second high voltage (e.g., [+-]2--8 kVDC) between the eluent at the capillary exit and a cathode spaced in front of the exit. A complete electrical circuit is formed by a conductor which directly contacts the eluent at the capillary exit, or by conduction through a sheath electrode discharged in an annular sheath flow about the capillary exit. 21 figs.

  5. Combined electrophoresis-electrospray interface and method

    DOEpatents

    Smith, Richard P.; Udseth, Harold R.; Olivares, Jose A.

    1989-01-01

    A system and method for analyzing molecular constituents of a composition sample includes: forming a solution of the sample, separating the solution by capillary electrophoresis into an eluent of constituents longitudinally separated according to their relative electrophoretic mobilities, electrospraying the eluent to form a charged spray in which the molecular constituents have a temporal distribution; and detecting or collecting the separated constituents in accordance with the temporal distribution in the spray. A first high-voltage (e.g., 5-100 KVDC) is applied to the solution. The spray is charged by applying a second high voltage (e.g., .+-.2-8 KVDC) between the eluent at the capillary exit and a cathode spaced in front of the exit. A complete electrical circuit is formed by a conductor which directly contacts the eluent at the capillary exit, or by conduction through a sheath electrode discharged in an annular sheath flow about the capillary exit.

  6. Separation of alpha-lactalbumin grafted- and non-grafted maghemite core/silica shell nanoparticles by capillary zone electrophoresis.

    PubMed

    Petr, Jan; Teste, Bruno; Descroix, Stéphanie; Siaugue, Jean-Michel; Gareil, Pierre; Varenne, Anne

    2010-08-01

    The use of nanoparticles (NPs) in immunodiagnostics is a challenging task for many reasons, including the need for miniaturization. In view of the development of an assay dedicated to an original, miniaturized and fully automated immunodiagnostics which aims to mimic in vivo interactions, magnetic zwitterionic bifunctional amino/polyethyleneoxide maghemite core/silica shell NPs functionalized with allergenic alpha-lactalbumin were characterized by CE. Proper analytical performances were obtained through semi-permanent capillary coating with didodecyldimethylammonium bromide (DDAB) or permanent capillary wall modification by hydroxypropylcellulose. The influence of experimental conditions (e.g. buffer component nature, pH, ionic strength, and electric field strength) on sample stability, electrophoretic mobility, and dispersion was investigated using either DDAB- or hydroxypropylcellulose-coated capillaries. Adsorption to the capillary wall and aggregation phenomena were evaluated according to the CE conditions. The proper choice of experimental conditions, i.e. separation under -10 kV in a 25 mM ionic strength MES/NaOH (pH 6.0) with a DDAB-coated capillary, allowed the separation of the grafted and the non-grafted NPs.

  7. Transport, manipulation, and reaction of biological cells on-chip using electrokinetic effects.

    PubMed

    Li, P C; Harrison, D J

    1997-04-15

    A microfluidic system was fabricated on a glass chip to study mobilization of biological cells on-chip. Electroosmotic and/or electrophoretic pumping were used to drive the cell transport within a network of capillary channels. Whole cells such as Saccharomyces cerevisiae, canine erythrocyte, and Escherichia coli were employed in this work. Photographs are presented to illustrate how cells are selected and transported from one location to another within the capillary network, with velocities up to about 0.5 mm/s in capillaries with a 15- x 55-microns cross section. The mixing of canine erythrocytes with the lysing agent sodium dodecyl sulfate, at an intersection within the chip, was performed to demonstrate that cell selection and subsequent reaction can be accomplished within the microchip.

  8. Simple and effective label-free capillary electrophoretic analysis of sugars by complexation using quinoline boronic acids.

    PubMed

    Kubo, Takuya; Kanemori, Koichi; Kusumoto, Risa; Kawai, Takayuki; Sueyoshi, Kenji; Naito, Toyohiro; Otsuka, Koji

    2015-01-01

    An effective separation and detection procedure for sugars by capillary electrophoresis (CE) using a complexation between quinolineboronic acid (QBA) and multiple hydroxyl structure of sugar alcohol is reported. We investigated the variation of fluorescence spectra of a variety of QBAs with sorbitol at a wide range of pH conditions and then found that 5-isoQBA strongly enhanced the fluorescence intensity by the complexation at basic pH conditions. The other sugar alcohols having multiple hydroxyls also revealed the enhancement of the fluorescence intensity with 5-isoQBA, whereas the alternation of the intensity was not found in the sugars such as glucose. After optimization of the 5-isoQBA concentration and pH of the buffered solution in CE analysis, 6 sugar alcohols were successfully separated in the order based on the formation constants with 5-isoQBA, which were calculated from the variation of the fluorescence intensity with each sugar alcohol and 5-isoQBA. Furthermore, the limits of detection for sorbitol and xylitol by the CE method were estimated at 15 and 27 μM, respectively.

  9. Chiral separation of benzoporphyrin derivative mono- and diacids by laser induced fluorescence-capillary electrophoresis.

    PubMed

    Peng, Xuejun; Sternberg, Ethan; Dolphin, David

    2002-01-01

    A method for the separation of benzoporphyrin derivative mono- and diacid (BPDMA, BPDDA) enantiomers by laser induced fluorescence-capillary electrophoresis (LIF-CE) has been developed. By using 300 mM borate buffer, pH 9.2, 25 mM sodium cholate and 10% acetronitrile as electrolyte, +10 kV electrokinetic sampling injection of 2 s and an applied +20 kV voltage across the ends of a 37 cm capillary (30 cm to the detector, 50 microm ID), all six BPD stereoisomers were baseline-separated within 20 min. Formation constants, free electrophoretic and complexation mobilities with borate and cholate were determined based on dynamic complexation capillary electrophoresis theory. The BPD enantiomers can be quantitatively determined in the range of 10(-2)-10(-5) mg mL(-1). The correlation coefficients (r2) of the least-squares linear regression analysis of the BPD enantiomers are in the range of 0.9914-0.9997. Their limits of detection are 2.18-3.5 x 10(-3) mg mL(-1). The relative standard deviations for the separation were 2.90-4.64% (n = 10). In comparison with high-performance liquid chromatography (HPLC), CE has better resolution and efficiency. This separation method was successfully applied to the BPD enantiomers obtained from a matrix of bovine serum and from liposomally formulated material as well as from studies with rat, dog and human microsomes.

  10. Prototyping of Poly(dimethylsiloxane) Interfaces for Flow Gating, Reagent Mixing, and Tubing Connection in Capillary Electrophoresis

    PubMed Central

    Zhang, Qiyang; Gong, Maojun

    2014-01-01

    Integrated microfluidic systems coupled with electrophoretic separations have broad application in biological and chemical analysis. Interfaces for the connection of various functional parts play a major role in the performance of a system. Here we developed a rapid prototyping method to fabricate monolithic poly(dimethylsiloxane) (PDMS) Interfaces for flow-gated injection, online reagent mixing, and tube-to-tube connection in an integrated capillary electrophoresis (CE) system. The basic idea was based on the properties of PDMS: elasticity, transparency, and suitability for prototyping. The molds for these interfaces were prepared by using commercially available stainless steel wires and nylon lines or silica capillaries. A steel wire was inserted through the diameter of a nylon line and a cross format was obtained as the mold for PDMS casting of flow gates and 4-way mixers. These interfaces accommodated tubing connection through PDMS elasticity and provided easy visual trouble shooting. The flow gate used smaller channel diameters thus reducing flow rate by 25 fold for effective gating compared with mechanically machined counterparts. Both PDMS mixers and the tube-to-tube connectors could minimize the sample dead volume by using an appropriate capillary configuration. As a whole, the prototyped PDMS interfaces are reusable, inexpensive, convenient for connection, and robust when integrated with the CE detection system. Therefore, these interfaces could see potential applications in CE and CE-coupled systems. PMID:24331370

  11. Determination of pKa values of benzoxa-, benzothia- and benzoselena-zolinone derivatives by capillary electrophoresis. Comparison with potentiometric titration and spectrometric data.

    PubMed

    Foulon, C; Duhal, N; Lacroix-Callens, B; Vaccher, C; Bonte, J P; Goossens, J F

    2007-07-01

    Acidity constants of benzoxa-, benzothia- and benzoselena-zolinone derivatives were determined by capillary electrophoresis, potentiometry and spectrophotometry experiments. These three analytical techniques gave pK(a) results that were in good agreement. A convenient, accurate and precise method for the determination of pK(a) was developed to measure changes in acidity constants induced by heteroatom or 6-benzoyl substituted derivatives. pK(a) values were determined simultaneously for two compounds characterized by different electrophoretic mobility (micro(e)) and pK(a) value and in the presence of an analogous neutral marker.

  12. Fundamentals of capillary electrochromatography: migration behavior of ionized sample components.

    PubMed

    Xiang, Rong; Horváth, Csaba

    2002-02-15

    The mechanism of separating charged species by capillary electrochromatography (CEC) was modeled with the conditions of ideal/linear chromatography by using a simple random walk. The most novel aspect of the work rests with the assumption that in sufficiently high electric field ionized sample components can also migrate in the adsorbed state on the ionized surface of the stationary phase. This feature of CEC leads to the introduction of three dimensionless parameters: alpha, reduced mobility of a sample component with the electrosmotic mobility as the reference; beta, the CEC retention factor; and gamma, the ratio of the electrophoretic migration velocity and the velocity of surface electrodiffusion. Since the interplay of retentive and electrophoretic forces determines the overall migration velocity, the separation mechanism in CEC is governed by the relative importance of the above parameters. The model predicts conditions under which the features of the CEC system engender migration behavior that manifests itself in a relatively narrow elution window and in a gradient like elution pattern in the separation of peptides and proteins by using pro forma isocratic CEC. It is believed that such elution patterns, which resemble those obtained by the use of external gradient of the eluent, are brought about by the formation of an internal gradient in the CEC system that gave rise to concomitant peak compression. The peculiarities of CEC are discussed in the three operational modalities of the technique: co-current, countercurrent, and co-counter CEC. The results suggest that CEC, which is often called "liquid chromatography on electrophoretic platform" is an analytical tool with great potential in the separation of peptides and proteins.

  13. On-line capillary electrophoresis-based enzymatic methodology for the study of polymer-drug conjugates.

    PubMed

    Coussot, G; Ladner, Y; Bayart, C; Faye, C; Vigier, V; Perrin, C

    2015-01-09

    This work aims at studying the potentialities of an on-line capillary electrophoresis (CE)-based digestion methodology for evaluating polymer-drug conjugates degradability in the presence of free trypsin (in-solution digestion). A sandwich plugs injection scheme with transverse diffusion of laminar profile (TDLFP) mode was used to achieve on-line digestions. Electrophoretic separation conditions were established using poly-l-Lysine (PLL) as reference substrate. Comparison with off-line digestion was carried out to demonstrate the feasibility of the proposed methodology. The applicability of the on-line CE-based digestion methodology was evaluated for two PLL-drug conjugates and for the four first generations of dendrigraft of lysine (DGL). Different electrophoretic profiles presenting the formation of di, tri, and tetralysine were observed for PLL-drug and DGL. These findings are in good agreement with the nature of the linker used to link the drug to PLL structure and the predicted degradability of DGL. The present on-line methodology applicability was also successfully proven for protein conjugates hydrolysis. In summary, the described methodology provides a powerful tool for the rapid study of biodegradable polymers. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Serum protein electrophoretic pattern in one-humped camels (Camelus dromedarius) in Tripoli, Libya.

    PubMed

    Abdoslam, Omran; Bayt-Almal, Mahmoud; Almghrbe, Abdullah; Algriany, Omran

    2018-01-01

    The aim of this study was to characterize serum protein capillary electrophoretic pattern in apparently healthy adult male (age: 3-7 years) dromedary camels and also evaluate total protein and albumin levels using automated analyzer. Blood samples were taken from 20 camels. 5ml of blood was collected from the jugular vein and serum was separated from samples by centrifugation. Capillary electrophoresis of serum proteins identified six protein fractions in adult camels, including albumin, alpha1, alpha2, beta1, beta2 and gamma globulins, serum levels of these parameters were 3.9±0.04 g/dl, 0.16±0.01 g/dl, 0.39±0.03 g/dl, 0.515±0.03 g/dl, 0.205±0.01 g/dl and 0.61±0.04 g/dl, and 65.42±0.62 g/l, respectively. The total protein concentration was 65.42±0.62 g/L, while, the albumin/globulin (A/G) ratio was 2.4±0.14. The present study indicates six peaks with minicapillary electrophoresis and the results obtained were compared and interpreted in the light of finding reported by other investigators in camels.

  15. Capillary electrophoresis coupled with mass spectrometry for the evaluation of substance P enzymatic degradation by SaOS-2 human osteosarcoma.

    PubMed

    Cavazza, Antonella; Corradini, Claudio; Marini, Mario; Roda, Luigi Giorgio; Valenti, Angela

    2011-09-01

    A new analytical method for the detection and the quantitative evaluation of the undecapeptide substance P by capillary electrophoresis coupled with ion trap mass spectrometry (CE-MS) by a co-axial sheath liquid interface has been developed. Conditions of analysis employed an acidic buffer and a 60 cm fused silica capillary installed by overcoming the UV window position, thus allowing to perform the analysis in a brief time. The method has been applied to the evaluation of substance P enzymatic hydrolysis during incubation with the human osteosarcoma SaOS-2 cell line. The analysis of amino acids derived from the cleavage of substance P has been also carried out simultaneously under the same electrophoretic conditions allowing the description of a kinetic of amino acid formation, parallel with substance P disappearance. The amounts of intact substance P and of free amino acids were monitored along 600 s of incubation time. A steady decrease of substance P as function of reaction time was observed. Peptide's half-life was found to be about 4.3s, indicating an extremely fast hydrolysis in the presence of the SaOS-2 cells. Proline, phenilalanine and methionine were the predominant free amino acids recorded. Obtained results lead to hypothesize the occurrence of endopeptidases activity, followed by aminopeptidases responsible for the release of free amino acids originated after primary bond cleavage. Copyright © 2011 Elsevier B.V. All rights reserved.

  16. Fully packed capillary electrochromatographic microchip with self-assembly colloidal silica beads.

    PubMed

    Park, Jongman; Lee, Dami; Kim, Won; Horiike, Shigeyoshi; Nishimoto, Takahiro; Lee, Se Hwan; Ahn, Chong H

    2007-04-15

    A fully packed capillary electrochromatographic (CEC) microchip showing improved solution and chip handling was developed. Microchannels for the CEC microchip were patterned on a cyclic olefin copolymer substrate by injection molding and packed fully with 0.8-microm monodisperse colloidal silica beads utilizing a self-assembly packing technique. The silica packed chip substrate was covered and thermally press-bonded. After fabrication, the chip was filled with buffer solution by self-priming capillary action. The self-assembly packing at each channel served as a built-in nanofilter allowing quick loading of samples and running buffer solution without filtration. Because of a large surface area-to-volume ratio of the silica packing, reproducible control of electroosmotic flow was possible without leveling of the solutions in the reservoirs resulting 1.3% rsd in migration rate. The capillary electrophoretic separation characteristics of the chip were studied using fluorescein isothiocyanate (FITC)-derivatized amino acids as probe molecules. A mixture of FITC and four FITC-derivatized amino acids was successfully separated with 2-mm separation channel length.

  17. Pressure-assisted introduction of urine samples into a short capillary for electrophoretic separation with contactless conductivity and UV spectrometry detection.

    PubMed

    Makrlíková, Anna; Opekar, František; Tůma, Petr

    2015-08-01

    A computer-controlled hydrodynamic sample introduction method has been proposed for short-capillary electrophoresis. In the method, the BGE flushes sample from the loop of a six-way sampling valve and is carried to the injection end of the capillary. A short pressure impulse is generated in the electrolyte stream at the time when the sample zone is at the capillary, leading to injection of the sample into the capillary. Then the electrolyte flow is stopped and the separation voltage is turned on. This way of sample introduction does not involve movement of the capillary and both of its ends remain constantly in the solution during both sample injection and separation. The amount of sample introduced to the capillary is controlled by the duration of the pressure pulse. The new sample introduction method was tested in the determination of ammonia, creatinine, uric acid, and hippuric acid in human urine. The determination was performed in a capillary with an overall length of 10.5 cm, in two BGEs with compositions 50 mM MES + 5 mM NaOH (pH 5.1) and 1 M acetic acid + 1.5 mM crown ether 18-crown-6 (pH 2.4). A dual contactless conductivity/UV spectrometric detector was used for the detection. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Capillary ion electrophoresis of inorganic anions and uric acid in human saliva using a polyvinyl alcohol coated capillary column and hexamethonium chloride as additive of background electrolyte.

    PubMed

    Mori, Masanobu; Yamamoto, Tsukasa; Kaseda, Maki; Yamada, Sachiko; Itabashi, Hideyuki

    2012-03-01

    A combination of polyvinyl alcohol chemically coated capillary (PVA capillary) and background electrolyte (BGE) with ion-pair reagent (hexamethonium dichloride, HMC) was used on capillary ion electrophoresis-UV detection (CIE-UV) for analysis of Br⁻, I⁻, NO₂⁻, NO₃⁻, SCN⁻ and uric acid in human saliva. The PVA capillary prepared in our laboratory minimized electro-osmotic flow (EOF) at the BGE in pH 3-10, and did not affect the UV detection at 210 nm by the PVA-layer on capillary wall. Therefore, use of the PVA capillary was suitable for sensitive UV detection for analyte anions, as well as suppression of protein adsorption. In this study, we optimized the BGE of 10 mM phosphate plus 10 mM HMC with applying a voltage of -15 kV. HMC as an additive to BGE could manipulate the electrophoretic mobility of anions, without electrostatic adsorption to the PVA capillary. The CIE-UV could separate and determine analyte anions in human saliva containing proteins by the direct injection without pretreatments such as dilution or deproteinization within 13 min. The relative standard deviations (n=10) were ranged of 0.5-1.6% in migration times, 2.2-6.8% in peak heights and 2.8-8.4% in peak areas. The limits of detection (S/N=3) were ranged of 3.42-6.87 μM. The peak height of anions in this system was gradually decreased through the successive injections of saliva samples, but the problem was successfully solved by periodically conditioning the PVA capillary. The quantifiability of anions in human saliva samples by the CIE-UV was evaluated through the recoveries by standard addition methods and comparison of other representative analytical methods, as well as identification by ion chromatography (IC). From the anion analyses in 12 different saliva samples, the CIE-UV demonstrated that can obtain obvious differences in concentrations of SCN⁻ between of smoker and non-smoker and those of uric acid between male and female with satisfactory results. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Detection and Quantification of 8-Hydroxy-2′-Deoxyguanosine in Alzheimer’s Transgenic Mouse Urine using Capillary Electrophoresis

    PubMed Central

    Zhang, Cheng; Nestorova, Gergana; Rissman, Robert A.; Feng, June

    2013-01-01

    8-Hydroxy-2′-deoxyguanosine (8-OHdG) is one of the major forms of oxidative deoxyribonucleic acid (DNA) damage, and is commonly analyzed as an excellent marker of DNA lesions. The purpose of this study was to develop a sensitive method to accurately and rapidly quantify the 8-OHdG by using capillary electrophoresis with laser-induced fluorescence detection (CE-LIF). The method involved the use of specific antibody to detect DNA lesions (8-OHdG) and consecutive fluorescence labeling. Next, the urine sample with 8-OHdG fluorescently labeled along with other constituents was resolved by capillary electrophoretic system and the lesion of interest was detected using fluorescence detector. The limit of detection was 0.18 fmol, which is sufficient sensitivity for detection and quantification of 8-OHdG in untreated urine samples. The relative standard deviation (RSD) was found to be 11.32 % for migration time, and 5.52 % for peak area. To demonstrate the utility of this method, the urinary concentration of 8-OHdG in an Alzheimer’s transgenic mouse model was determined. Collectively, our results indicate that this methodology offers great advantages such as high separation efficiency, good selectivity, low limit of detection (LOD), simplicity and low cost of analysis. PMID:23712533

  20. Enantioseparation of rabeprazole and omeprazole by nonaqueous capillary electrophoresis with an ephedrine-based ionic liquid as the chiral selector.

    PubMed

    Ma, Zheng; Zhang, Lijuan; Lin, Lina; Ji, Ping; Guo, Xingjie

    2010-12-01

    An ephedrine-based chiral ionic liquid, (+)-N,N-dimethylephedrinium-bis(trifluoromethanesulfon)imidate ([DMP](+) [Tf(2) N](-) ), served as both chiral selector and background electrolyte in nonaqueous capillary electrophoresis. The enantioseparation of rabeprazole and omeprazole was achieved in acetonitrile-methanol (60:40 v/v) containing 60 mm[DMP](+) [Tf(2) N](-) . The influences of separation conditions, including the concentration of [DMP](+) [Tf(2) N](-) , the electrophoretic media and the buffer, on enantioseparation were evaluated. The mechanism of enantioseparation was investigated and discussed. Ion-pair interaction and hydrogen bonding may be responsible for the main separation mechanism. Copyright © 2010 John Wiley & Sons, Ltd.

  1. Rapid CE-UV binding tests of environmentally hazardous compounds with polymer-modified magnetic nanoparticles.

    PubMed

    Iqbal, Zafar; Alsudir, Samar; Miah, Musharraf; Lai, Edward P C

    2011-08-01

    Hazardous compounds and bacteria in water have an adverse impact on human health and environmental ecology. Polydopamine (or polypyrrole)-coated magnetic nanoparticles and polymethacrylic acid-co-ethylene glycol dimethacrylate submicron particles were investigated for their fast binding kinetics with bisphenol A, proflavine, naphthalene acetic acid, and Escherichia coli. A new method was developed for the rapid determination of % binding by sequential injection of particles first and compounds (or E. coli) next into a fused-silica capillary for overlap binding during electrophoretic migration. Only nanolitre volumes of compounds and particles were sufficient to complete a rapid binding test. After heterogeneous binding, separation of the compounds from the particles was afforded by capillary electrophoresis. % binding was influenced by applied voltage but not current flow. In-capillary coating of particles affected the % binding of compounds. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Capillary electrophoresis for aluminum ion speciation: Optimized separation conditions for complex polycation mixtures.

    PubMed

    Ouadah, Nesrine; Moire, Claudine; Brothier, Fabien; Kuntz, Jean-François; Deschaume, Olivier; Bartic, Carmen; Cottet, Hervé

    2018-06-01

    Aluminum chlorohydrates (ACH) are used in numerous applications and commercial products on a global scale including water treatment, catalysis or antiperspirants. They are complex mixtures of water soluble aluminum polycations of different degrees of polymerization, that are difficult to separate and quantify due to their susceptibility to depolymerize in solution when placed out of equilibrium, which is inherent to any separation process. We recently achieved the first capillary electrophoresis separation and characterization of ACH oligomers using 4-morpholineethanesulfonic acid (MES) as background electrolyte counter-ion. MES stabilizes the separated ACH oligomers during the electrophoretic process leading to highly repeatable and fast separations. In this work, the separation of ACH oligomers was further studied and perfected by varying the ionic strength, MES concentration and pH of the background electrolyte. Complex electrophoretic behavior is reported for the separation of Al 13 , Al 30 and Na + ions according to these experimental parameters. The transformation of the electropherograms in effective mobility scale and the use of the slope-plot approach are used to better understand the observed changes in selectivity/resolution. Optimal conditions (700 mM MES at 25 mM ionic strength containing 0.1 mM didodecyldimethylammonium bromide for dynamic capillary coating, pH 4.8) obtained for the separation of ACH oligomers are used for the baseline separation of samples difficult to analyze with other methods, including different molecular, aggregated and colloidal forms of aluminum from the Al 13 , Al 30 and Na + mixture, validating the rationale of the approach. Copyright © 2018. Published by Elsevier B.V.

  3. A method for UV-bonding in the fabrication of glass electrophoretic microchips.

    PubMed

    Huang, Z; Sanders, J C; Dunsmor, C; Ahmadzadeh, H; Landers, J P

    2001-10-01

    This paper presents an approach for the development of methodologies amenable to simple and inexpensive microchip fabrication, potentially applicable to dissimilar materials bonding and chip integration. The method involves a UV-curable glue that can be used for glass microchip fabrication bonding at room temperature. This involves nothing more than fabrication of glue "guide channels" into the microchip architecture that upon exposure to the appropriate UV light source, bonds the etched plate and cover plate together. The microchip performance was verified by capillary zone electrophoresis (CZE) of small fluorescent molecules with no microchannel surface modification carried out, as well as with a DNA fragment separation following surface modification. The performance of these UV-bonded electrophoretic microchips indicates that this method may provide an alternative to high temperature bonding.

  4. Continuous cell introduction and rapid dynamic lysis for high-throughput single-cell analysis on microfludic chips with hydrodynamic focusing.

    PubMed

    Xu, Chun-Xiu; Yin, Xue-Feng

    2011-02-04

    A chip-based microfluidic system for high-throughput single-cell analysis is described. The system was integrated with continuous introduction of individual cells, rapid dynamic lysis, capillary electrophoretic (CE) separation and laser induced fluorescence (LIF) detection. A cross microfluidic chip with one sheath-flow channel located on each side of the sampling channel was designed. The labeled cells were hydrodynamically focused by sheath-flow streams and sequentially introduced into the cross section of the microchip under hydrostatic pressure generated by adjusting liquid levels in the reservoirs. Combined with the electric field applied on the separation channel, the aligned cells were driven into the separation channel and rapidly lysed within 33ms at the entry of the separation channel by Triton X-100 added in the sheath-flow solution. The maximum rate for introducing individual cells into the separation channel was about 150cells/min. The introduction of sheath-flow streams also significantly reduced the concentration of phosphate-buffered saline (PBS) injected into the separation channel along with single cells, thus reducing Joule heating during electrophoretic separation. The performance of this microfluidic system was evaluated by analysis of reduced glutathione (GSH) and reactive oxygen species (ROS) in single erythrocytes. A throughput of 38cells/min was obtained. The proposed method is simple and robust for high-throughput single-cell analysis, allowing for analysis of cell population with considerable size to generate results with statistical significance. Copyright © 2010 Elsevier B.V. All rights reserved.

  5. A replaceable dual-enzyme capillary microreactor using magnetic beads and its application for simultaneous detection of acetaldehyde and pyruvate.

    PubMed

    Shi, Jing; Zhao, Wenwen; Chen, Yuanfang; Guo, Liping; Yang, Li

    2012-07-01

    A novel replaceable dual-enzyme capillary microreactor was developed and evaluated using magnetic fields to immobilize the alcohol dehydrogenase (ADH)- and lactate dehydrogenase (LDH)-coated magnetic beads at desired positions in the capillary. The dual-enzyme assay was achieved by measuring the two consumption peaks of the coenzyme β-nicotinamide adenine dinucleotide (NADH), which were related to the ADH reaction and LDH reaction. The dual-enzyme capillary microreactor was constructed using magnetic beads without any modification of the inner surface of the capillary, and showed great stability and reproducibility. The electrophoretic resolution for different analytes can be easily controlled by altering the relative distance of different enzyme-coated magnetic beads. The apparent K(m) values for acetaldehyde with ADH-catalyzed reaction and for pyruvate with LDH-catalyzed reaction were determined. The detection limits for acetaldehyde and pyruvate determination are 0.01 and 0.016 mM (S/N = 3), respectively. The proposed method was successfully applied to simultaneously determine the acetaldehyde and pyruvate contents in beer samples. The results indicated that combing magnetic beads with CE is of great value to perform replaceable and controllable multienzyme capillary microreactor for investigation of a series of enzyme reactions and determination of multisubstrates. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Microfluidic devices fabricated in poly(methyl methacrylate) using hot-embossing with integrated sampling capillary and fiber optics for fluorescence detection.

    PubMed

    Qi, Shize; Liu, Xuezhu; Ford, Sean; Barrows, James; Thomas, Gloria; Kelly, Kevin; McCandless, Andrew; Lian, Kun; Goettert, Jost; Soper, Steven A

    2002-05-01

    High-aspect-ratio microstructures have been prepared using hot-embossing techniques in poly(methyl methacrylate) (PMMA) from Ni-based molding dies prepared using LIGA (Lithographie, Galvanoformung, Abformung). Due to the small amount of mask undercutting associated with X-ray lithography and the high energy X-ray beam used during photoresist patterning, deep structures with sharp and smooth sidewalls have been prepared. The Ni-electroforms produced devices with minimal replication errors using hot-embossing at a turn around time of approximately 5 min per device. In addition, several different polymers (with different glass transition temperatures) could be effectively molded with these Ni-electroforms and many devices (>300) molded with the same master without any noticeable degradation. The PMMA devices consisted of deep and narrow channels for insertion of a capillary for the automated electrokinetic loading of sample into the microfluidic device and also, a pair of optical fibers for shuttling laser light to the detection zone and collecting the resulting emission for fluorescence analysis. Electrophoretic separations of double-stranded DNA ladders Phi X174 digested with Hae III) were performed with fluorescence detection accomplished using near-IR excitation. It was found that the narrow width of the channels did not contribute significantly to electrophoretic zone broadening and the plate numbers generated in the extended length separation channel allowed sorting of the 271/281 base pair fragments associated with this sizing ladder when electrophoresed in methylcellulose entangled polymer solutions. The dual fiber detector produced sub-attomole detection limits with the entire detector, including laser source, electronics and photon transducer, situated in a single box measuring 3'' x 10" x 14".

  7. Micelle to solvent stacking of organic cations in micellar electrokinetic chromatography with sodium dodecyl sulfate.

    PubMed

    Quirino, Joselito P; Aranas, Agnes T

    2011-10-14

    The on-line sample concentration technique, micelle to solvent stacking (MSS), was studied for small organic cations (quaternary ammonium herbicides, β-blocker drugs, and tricyclic antidepressant drugs) in reversed migration micellar electrokinetic chromatography. Electrokinetic chromatography was carried out in fused silica capillaries with a background solution of sodium dodecyl sulfate (SDS) in a low pH phosphate buffer. MSS was performed using anionic SDS micelles in the sample solution for analyte transport and methanol or acetonitrile as organic solvent in the background solution for analyte effective electrophoretic mobility reversal. The solvent also allowed for the separation of the analyte test mixtures. A model for focusing and separation was developed and the mobility reversal that involved micelle collapse was experimentally verified. The effect of analyte retention factor was observed by changing the % organic solvent in the background solution or the concentration of SDS in the sample matrix. With an injection length of 31.9 cm (77% of effective capillary length) for the 7 test drugs, the LODs (S/N=3) of 5-14 ng/mL were 101-346-fold better when compared to typical injection. The linearity (R(2), range=0.025-0.8 μg/mL), intraday and interday repeatability (%RSD, n=10) were ≥0.988, <6.0% and <8.5%, respectively. In addition, analysis of spiked urine samples after 10-fold dilution with the sample matrix yielded LODs=0.02-0.10 μg/mL. These LODs are comparable to published electrophoretic methods that required off-line sample concentration. However, the practicality of the technique for more complex samples will rely on dedicated sample preparation schemes. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. High resolution melting analysis (HRM) for the assessment of clonality in feline B-cell lymphomas.

    PubMed

    Henrich, Manfred; Scheffold, Svenja; Hecht, Werner; Reinacher, Manfred

    2018-06-01

    Analysis of clonality is gaining importance in diagnosing lymphomas in veterinary medicine. Usually, PCR for the analysis of antigen receptor rearrangement (PARR) is followed by electrophoretic separation of the PCR products. Aim of this study was to test the feasibility of HRM for the assessment of clonality in B-cell lymphomas of cats. High resolution melting analysis differentiates PCR products by their different melting point using the decrease in fluorescence of an intercalating dye during melting of the PCR product. Additionally, the method is easy to use with no post-PCR manipulation of the samples. Forty-seven feline B-cell lymphomas and 31 reactive lymphatic proliferations of cats were investigated by PARR followed either by capillary electrophoresis or an HRM assay. To objectify the interpretation of the HRM results a recently published mathematical approach was applied to the melting curve. To overcome discrepancies between the visual interpretation and the mathematical approach, the latter was modified to include testing of reproducibility and recognition of pseudoclonality. In 11 of 47 lymphoma cases clonal populations were detectable by HRM assay compared to 14 of 47 lymphomas in which clonal populations were detected by capillary electrophoresis assay. Neither of the methods showed a clonal pattern in any of the reactive samples. However, the HRM assay showed a unique pattern in cases of follicular lymphatic hyperplasia that had no corresponding pattern in capillary electrophoresis. The capillary electrophoresis assay could identify 3 lymphomas that were not detected by the HRM assay and is therefore regarded superior to the HRM assay. The comparison however, was hampered by the overall bad performance of the PARR, that might be the consequence of insufficient primer binding due to somatic hypermutation of the binding sites during antigen stimulated proliferation of the B lymphocytes. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Dynamic computer simulations of electrophoresis: three decades of active research.

    PubMed

    Thormann, Wolfgang; Caslavska, Jitka; Breadmore, Michael C; Mosher, Richard A

    2009-06-01

    Dynamic models for electrophoresis are based upon model equations derived from the transport concepts in solution together with user-inputted conditions. They are able to predict theoretically the movement of ions and are as such the most versatile tool to explore the fundamentals of electrokinetic separations. Since its inception three decades ago, the state of dynamic computer simulation software and its use has progressed significantly and Electrophoresis played a pivotal role in that endeavor as a large proportion of the fundamental and application papers were published in this periodical. Software is available that simulates all basic electrophoretic systems, including moving boundary electrophoresis, zone electrophoresis, ITP, IEF and EKC, and their combinations under almost exactly the same conditions used in the laboratory. This has been employed to show the detailed mechanisms of many of the fundamental phenomena that occur in electrophoretic separations. Dynamic electrophoretic simulations are relevant for separations on any scale and instrumental format, including free-fluid preparative, gel, capillary and chip electrophoresis. This review includes a historical overview, a survey of current simulators, simulation examples and a discussion of the applications and achievements of dynamic simulation.

  10. High-performance genetic analysis on microfabricated capillary array electrophoresis plastic chips fabricated by injection molding.

    PubMed

    Dang, Fuquan; Tabata, Osamu; Kurokawa, Masaya; Ewis, Ashraf A; Zhang, Lihua; Yamaoka, Yoshihisa; Shinohara, Shouji; Shinohara, Yasuo; Ishikawa, Mitsuru; Baba, Yoshinobu

    2005-04-01

    We have developed a novel technique for mass production of microfabricated capillary array electrophoresis (mu-CAE) plastic chips for high-speed, high-throughput genetic analysis. The mu-CAE chips, containing 10 individual separation channels of 50-microm width, 50-microm depth, and a 100-microm lane-to-lane spacing at the detection region and a sacrificial channel network, were fabricated on a poly(methyl methacrylate) substrate by injection molding and then bonded manually using a pressure-sensitive sealing tape within several seconds at room temperature. The conditions for injection molding and bonding were carefully characterized to yield mu-CAE chips with well-defined channel and injection structures. A CCD camera equipped with an image intensifier was used to monitor simultaneously the separation in a 10-channel array with laser-induced fluorescence detection. High-performance electrophoretic separations of phiX174 HaeIII DNA restriction fragments and PCR products related to the human beta-globin gene and SP-B gene (the surfactant protein B) have been demonstrated on mu-CAE plastic chips using a methylcellulose sieving matrix in individual channels. The current work demonstrated greatly simplified the fabrication process as well as a detection scheme for mu-CAE chips and will bring the low-cost mass production and application of mu-CAE plastic chips for genetic analysis.

  11. Highly sensitive chiral analysis in capillary electrophoresis with large-volume sample stacking with an electroosmotic flow pump.

    PubMed

    Kawai, Takayuki; Koino, Hiroshi; Sueyoshi, Kenji; Kitagawa, Fumihiko; Otsuka, Koji

    2012-07-13

    To improve the sensitivity in chiral analysis by capillary electrophoresis without loss of optical resolution, application of large-volume sample stacking with an electroosmotic flow pump (LVSEP) was investigated. Effects of the addition of cyclodextrin (CD) into a running solution on the LVSEP preconcentration was theoretically studied, where the preconcentration efficiency and effective separation length would be slightly increased if the effective electrophoretic velocity (v(ep,eff,BGS)) of the analytes was decreased by interacting with CD. In LVSEP-CD-modified capillary zone electrophoresis (CDCZE) and LVSEP-CD electrokinetic chromatography with reduced v(ep,eff,BGS), up to 1000-fold sensitivity increases were achieved with almost no loss of resolution. In LVSEP-CD-modified micellar electrokinetic chromatography of amino acids with increased v(ep,eff,BGS), a 1300-fold sensitivity increase was achieved without much loss of resolution, indicating the versatile applicability of LVSEP to many separation modes. An enantio-excess (EE) assay was also carried out in LVSEP-CDCZE, resulting in successful analyses of up to 99.6% EE. Finally, we analyzed ibuprofen in urine by desalting with a C₁₈ solid-phase extraction column. As a typical result, 250ppb ibuprofen was well concentrated and optically resolved with 84.0-86.6% recovery in LVSEP-CDCZE, indicating the applicability of LVSEP to real samples containing a large amount of unnecessary background salts. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. Characterization of Nanoparticles by Capillary Electrophoresis and Trapping of Nanoparticles in Microfluidics Device

    DTIC Science & Technology

    2009-08-01

    tubular mode driven by electroosmotic flow and the inherent electrophoretic mobility of the analytes under the influence of an applied electric field...could be due to unlabeled beads. Figure 3 (C and D) also shows electropherogram of a neutral electroosmotic flow (EOF) marker dye BODIPY and...internal turbulent mixing . The current microfabricated electromagnets cannot produce sufficient fields to trap the NPs against a large flow forces

  13. Polyacrylamide medium for the electrophoretic separation of biomolecules

    DOEpatents

    Madabhushi, Ramakrishna S.; Gammon, Stuart A.

    2003-11-11

    A polyacryalmide medium for the electrophoretic separation of biomolecules. The polyacryalmide medium comprises high molecular weight polyacrylamides (PAAm) having a viscosity average molecular weight (M.sub.v) of about 675-725 kDa were synthesized by conventional red-ox polymerization technique. Using this separation medium, capillary electrophoresis of BigDye DNA sequencing standard was performed. A single base resolution of .about.725 bases was achieved in .about.60 minute in a non-covalently coated capillary of 50 .mu.m i.d., 40 cm effective length, and a filed of 160 V/cm at 40.degree. C. The resolution achieved with this formulation to separate DNA under identical conditions is much superior (725 bases vs. 625 bases) and faster (60 min. vs. 75 min.) to the commercially available PAAm, such as supplied by Amersham. The formulation method employed here to synthesize PAAm is straight-forward, simple and does not require cumbersome methods such as emulsion polymerizaiton in order to achieve very high molecular weights. Also, the formulation here does not require separation of PAAm from the reaction mixture prior to reconstituting the polymer to a final concentration. Furthermore, the formulation here is prepared from a single average mol. wt. PAAm as opposed to the mixture of two different average mo. wt. PAAm previously required to achieve high resolution.

  14. 21 CFR 864.7440 - Electrophoretic hemoglobin analysis system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Electrophoretic hemoglobin analysis system. 864.7440 Section 864.7440 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN....7440 Electrophoretic hemoglobin analysis system. (a) Identification. An electrophoretic hemoglobin...

  15. 21 CFR 864.7440 - Electrophoretic hemoglobin analysis system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Electrophoretic hemoglobin analysis system. 864.7440 Section 864.7440 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN....7440 Electrophoretic hemoglobin analysis system. (a) Identification. An electrophoretic hemoglobin...

  16. 21 CFR 864.7440 - Electrophoretic hemoglobin analysis system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Electrophoretic hemoglobin analysis system. 864.7440 Section 864.7440 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN....7440 Electrophoretic hemoglobin analysis system. (a) Identification. An electrophoretic hemoglobin...

  17. 21 CFR 864.7440 - Electrophoretic hemoglobin analysis system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Electrophoretic hemoglobin analysis system. 864.7440 Section 864.7440 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN....7440 Electrophoretic hemoglobin analysis system. (a) Identification. An electrophoretic hemoglobin...

  18. 21 CFR 864.7440 - Electrophoretic hemoglobin analysis system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electrophoretic hemoglobin analysis system. 864.7440 Section 864.7440 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN....7440 Electrophoretic hemoglobin analysis system. (a) Identification. An electrophoretic hemoglobin...

  19. Structural analysis of low molecular weight heparin by ultraperformance size exclusion chromatography/time of flight mass spectrometry and capillary zone electrophoresis.

    PubMed

    Zhang, Qianqian; Chen, Xi; Zhu, Zhijia; Zhan, Xueqiang; Wu, Yanfang; Song, Lankun; Kang, Jingwu

    2013-02-05

    Although low molecular weight heparins (LMWHs) have been used as anticoagulant agents for over 2 decades, their structures have not been fully characterized. In this work, we propose a new strategy for the comprehensive structural analysis of LMWHs based on the combination of ultraperformance size exclusion chromatography/electrospray quadruple time-of-flight-mass spectrometry (UPSEC/Q-TOF-MS) and capillary zone electrophoresis (CZE). More than 70 components, including oligosaccharides with special structures such as 1,6-anhydro rings, saturated uronic acid at the nonreducing end and odd-numbered saccharides units were identified with UPSEC/Q-TOF-MS. Furthermore, a more detailed compositional analysis was accomplished by CZE analysis. PEG10000 and MgCl(2) were added to the background electrolyte to separate those saccharides with the nearly same charge-to-mass ratio. Baseline separation and quantification of all the building blocks of the most complex LMWH, namely, enoxaparin, which include 10 disaccharides, 1 trisaccharide, 2 tetrasaccharides, and, of particular importance, 4 1,6-anhyro derivatives, was achieved using CZE for the first time. Additionally, the peaks of oligosaccharides, in the absence of commercially available standards, were assigned on the basis of the linear correlation between the electrophoretic mobilities of oligosaccharides and their charge-to-mass ratios. These two approaches are simple and robust for structural analysis of LMWHs.

  20. Ultra-High-Speed DNA Fragment Separations Using Microfabricated Capillary Array Electrophoresis Chips

    NASA Astrophysics Data System (ADS)

    Woolley, Adam T.; Mathies, Richard A.

    1994-11-01

    Capillary electrophoresis arrays have been fabricated on planar glass substrates by photolithographic masking and chemical etching techniques. The photolithographically defined channel patterns were etched in a glass substrate, and then capillaries were formed by thermally bonding the etched substrate to a second glass slide. High-resolution electrophoretic separations of φX174 Hae III DNA restriction fragments have been performed with these chips using a hydroxyethyl cellulose sieving matrix in the channels. DNA fragments were fluorescently labeled with dye in the running buffer and detected with a laser-excited, confocal fluorescence system. The effects of variations in the electric field, procedures for injection, and sizes of separation and injection channels (ranging from 30 to 120 μm) have been explored. By use of channels with an effective length of only 3.5 cm, separations of φX174 Hae III DNA fragments from ≈70 to 1000 bp are complete in only 120 sec. We have also demonstrated high-speed sizing of PCR-amplified HLA-DQα alleles. This work establishes methods for high-speed, high-throughput DNA separations on capillary array electrophoresis chips.

  1. Ionic liquids in chromatographic and electrophoretic techniques: toward additional improvements in the separation of natural compounds

    PubMed Central

    Freire, Carmen S. R.; Coutinho, João A. P.; Silvestre, Armando J. D.; Freire, Mara G.

    2016-01-01

    Due to their unique properties, in recent years, ionic liquids (ILs) have been largely investigated in the field of analytical chemistry. Particularly during the last sixteen years, they have been successfully applied in the chromatographic and electrophoretic analysis of value-added compounds extracted from biomass. Considering the growing interest in the use of ILs in this field, this critical review provides a comprehensive overview on the improvements achieved using ILs as constituents of mobile or stationary phases in analytical techniques, namely in capillary electrophoresis and its different modes, in high performance liquid chromatography, and in gas chromatography, for the separation and analysis of natural compounds. The impact of the IL chemical structure and the influence of secondary parameters, such as the IL concentration, temperature, pH, voltage and analysis time (when applied), are also critically addressed regarding the achieved separation improvements. Major conclusions on the role of ILs in the separation mechanisms and the performance of these techniques in terms of efficiency, resolution and selectivity are provided. Based on a critical analysis of all published results, some target-oriented ILs are suggested. Finally, current drawbacks and future challenges in the field are highlighted. In particular, the design and use of more benign and effective ILs as well as the development of integrated (and thus more sustainable) extraction–separation processes using IL aqueous solutions are suggested within a green chemistry perspective. PMID:27667965

  2. Electrophoresis for the analysis of heparin purity and quality.

    PubMed

    Volpi, Nicola; Maccari, Francesca; Suwan, Jiraporn; Linhardt, Robert J

    2012-06-01

    The adulteration of raw heparin with oversulfated chondroitin sulfate (OSCS) in 2007-2008 produced a global crisis resulting in extensive revisions to the pharmacopeia monographs and prompting the FDA to recommend the development of additional methods for the analysis of heparin purity. As a consequence, a wide variety of innovative analytical approaches have been developed for the quality assurance and purity of unfractionated and low-molecular-weight heparins. This review discusses recent developments in electrophoresis techniques available for the sensitive separation, detection, and partial structural characterization of heparin contaminants. In particular, this review summarizes recent publications on heparin quality and related impurity analysis using electrophoretic separations such as capillary electrophoresis (CE) of intact polysaccharides and hexosamines derived from their acidic hydrolysis, and polyacrylamide gel electrophoresis (PAGE) for the separation of heparin samples without and in the presence of its relatively specific depolymerization process with nitrous acid treatment. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Electrophoresis for the analysis of heparin purity and quality

    PubMed Central

    Volpi, Nicola; Maccari, Francesca; Suwan, Jiraporn; Linhardt, Robert J.

    2012-01-01

    The adulteration of raw heparin with oversulfated chondroitin sulfate (OSCS) in 2007–2008 produced a global crisis resulting in extensive revisions to the pharmacopeia monographs and prompting the FDA to recommend the development of additional methods for the analysis of heparin purity. As a consequence, a wide variety of innovative analytical approaches have been developed for the quality assurance and purity of unfractionated and low-molecular-weight heparins. This review discusses recent developments in electrophoresis techniques available for the sensitive separation, detection, and partial structural characterization of heparin contaminants. In particular, this review summarizes recent publications on heparin quality and related impurity analysis using electrophoretic separations such as capillary electrophoresis (CE) of intact polysaccharides and hexosamines derived from their acidic hydrolysis, and polyacrylamide gel electrophoresis (PAGE) for the separation of heparin samples without and in the presence of its relatively specific depolymerization process with nitrous acid treatment. PMID:22736353

  4. Chaotropic salts: novel modifiers for the capillary electrophoretic analysis of benzodiazepines.

    PubMed

    Su, Hsiu-Li; Lan, Min-Tsu; Lin, Kuan-Wen; Hsieh, You-Zung

    2008-08-01

    This paper describes a CE method for analyzing benzodiazepines using the chaotropic salts lithium trifluoromethanesulfonate (LiOTf), lithium hexafluorophosphate (LiPF(6)), and lithium bis(trifluoromethanesulfonyl)imide (LiNTf(2)) as modifiers in the running buffer. Although adequate resolution of seven benzodiazepine analytes occurred under the influence of each of the chaotropic anions, the separation efficiency was highest when bis(trifluoromethanesulfonyl)imide (Tf(2)N(-)) was the modifier. We applied affinity CE in conjunction with linear analysis to determine the association constants for the formation of complexes between the Tf(2)N(-) anion and the benzodiazepines. According to the estimated Gibbs free energies, the interactions between this chaotropic anion and the benzodiazepines were either ion-dipole or ion-induced dipole interactions. Adding chaotropic salts as modifiers into CE buffers is a simple and reproducible technique for separating benzodiazepines.

  5. The early days of blotting.

    PubMed

    Southern, Edwin

    2015-01-01

    The history of the development of DNA blotting is described in this chapter. DNA blotting, involving the transfer of electrophoretically separated DNA fragments to a membrane support through capillary action, is also known as Southern blotting. This procedure enables the detection of a specific DNA sequence by hybridization with probes. The term Southern blotting led to a "geographic" naming tradition, with RNA blotting bearing the name Northern blotting and protein transfer to membranes becoming known as Western blotting.

  6. Recent highlights in electro-driven separations- selected applications of alkylthiol gold nanoparticles in capillary electrophoresis and capillary electro-chromatography.

    PubMed

    Guihen, Elizabeth

    2017-09-01

    To date, alkylthiol gold nanoparticles (AuNPs) have been widely used in electro-chromatographic separation techniques as a viable alternative to traditional stationary phases. This is mainly due to their stability, chemical inertness, ease of functionality, increased phase ratio, ability to form self-assembled monolayers. They also yield versatile stationary phases with highly specific targeted functionalities. At the nanoscale region, the chemical and physical properties of a molecule display different attributes to that of the parent molecules or material, hence these features can be harnessed in electro-driven chromatographic separations. Application areas illustrating the use of AuNPs in separation science continue to grow and expand to cover many different kinds of analysis. The last decade has witnessed a successful trend in miniaturisation of chemical separation systems toward the micro and nanoscale ranges. Nanoparticle-based stationary phases fit well with performing chemical separations on microfluidic and capillary platforms. In this review the theory of the use of alkylthiol gold nanoparticles in electro-chromatographic driven separation methods will be discussed. This will be followed by details of recent and selected applications showing alkylthiol gold nanoparticles in capillary electrophoretic and open-tubular electro-chromatographic separations. This review will focus solely on alkylthiol based gold nanoparticles, therefore other kinds of chemical moieties bonded to gold nanoparticles are outside the scope of this review. Finally the future outlook of this exciting technology will be outlined in some detail in the final section. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. In Situ Determination of Illegal Drugs in Oral Fluid by Portable Capillary Electrophoresis with Deep UV Excited Fluorescence Detection.

    PubMed

    Saar-Reismaa, Piret; Erme, Enn; Vaher, Merike; Kulp, Maria; Kaljurand, Mihkel; Mazina-Šinkar, Jekaterina

    2018-05-15

    The present study demonstrates the potential of a portable capillary electrophoresis (CE) instrument, coupled to deep UV fluorescence detector (FD) with a 230-255 nm excitation wavelength range, for the determination of the abuse of illegal drugs in oral fluids in situ. CE was introduced in this study due its exceptional power of separation and resolution, short analysis time, and ability for miniaturization for on-site assessment of different substances. The deep UV fluorescence detector was equipped with five interchangeable emission filters, in the emission wavelength range from 278 to 600 nm, and was successfully employed for determination of natively fluorescing illegal drugs, such as cocaine, cocaethylene, 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxeamphetamine (MDA), 3,4-methylenedioxy- N-ethylamphetamine (MDEA), para-methoxyamphetamine (PMA), para-methoxy- N-methylamphetamine (PMMA), amphetamine (AMP), methamphetamine (METH), tetrahydrocannabinol (THC) and cannabidiol (CBD). The developed FD showed impressive sensitivity. The instrumental detection limit was 0.5 μg/L for MDMA. It also showed broad linearity, up to 50 mg/L for MDMA. The noise CV% was 1.1% for an empty capillary and 0.6% for a capillary filled with acetonitrile. The portable CE-FD with developed electrophoretic methodologies was successfully utilized for the determination of illegal abuse of drugs during "Weekend" 2016 and 2017 Music Festivals (Estonia). Moreover, CE-FD can be employed for detection of other natively fluorescing compounds in the proposed range (e.g., for different phenolic compounds, BTEX, naphthalene derivatives, and others), significantly widening the applicability of developed CE-FD instrument.

  8. Capillary electrophoretic analysis of synthetic short-chain oligoribonucleotides.

    PubMed

    Cellai, L; Onori, A M; Desiderio, C; Fanali, S

    1998-12-01

    Thirty synthetic oligoribonucleotides, 3 to 18 nucleotides (nt) long, were analyzed by capillary electrophoresis, under nondenaturing conditions, using a commercial kit. The migration time t(m) was dependent on nt length and composition, capillary length, operating temperature, and type of sieving polymer. Under fixed experimental conditions, the t(m) proved predictable by the equation: t(m) = [0.22(n-1) + 6.14A/n + 6.86G/n + 3.61 (C+U)/n] min, for n>3, where A/n, G/n, C/n, U/n is the frequency of each type of nt within the oligonucleotide (ONT). The equation accounts for the influence of charge-to-mass ratio on t(m), but not for structural effects, if present. This approximation is acceptable for short ONTs. The possibility of detecting n+1, n-1, n-2 impurities, having predicted the t(m), is of crucial importance in assessing the purity of synthetic ONTs dedicated to structural studies. This appears to be feasible. High resolution was shown among homologous series of ONTs of increasing length, and in some cases, even within groups of ONTs of the same length but different composition. The addition of 7 M urea to the buffer, as denaturing agent, accelerates the t(m) and significantly lowers the resolution for the shortest ONTs. It was also possible to monitor the state of association of mixtures of RNA and DNA sequence-complementary strands.

  9. An accessible micro-capillary electrophoresis device using surface-tension-driven flow

    PubMed Central

    Mohanty, Swomitra K.; Warrick, Jay; Gorski, Jack; Beebe, David J.

    2010-01-01

    We present a rapidly fabricated micro-capillary electrophoresis chip that utilizes surface-tension-driven flow for sample injection and extraction of DNA. Surface-tension-driven flow (i.e. passive pumping) injects a fixed volume of sample that can be predicted mathematically. Passive pumping eliminates the need for tubing, valves, syringe pumps, and other equipment typically needed for interfacing with microelectrophoresis chips. This method requires a standard micropipette to load samples before separation, and remove the resulting bands after analysis. The device was made using liquid phase photopolymerization to rapidly fabricate the chip without the need of special equipment typically associated with the construction of microelectrophoresis chips (e.g. cleanroom). Batch fabrication time for the device presented here was 1.5 h including channel coating time to suppress electroosmotic flow. Devices were constructed out of poly-isobornyl acrylate and glass. A standard microscope with a UV source was used for sample detection. Separations were demonstrated using Promega BenchTop 100 bp ladder in hydroxyl ethyl cellulose (HEC) and oligonucleotides of 91 and 118 bp were used to characterize sample injection and extraction of DNA bands. The end result was an inexpensive micro-capillary electrophoresis device that uses tools (e.g. micropipette, electrophoretic power supplies, and microscopes) already present in most labs for sample manipulation and detection, making it more accessible for potential end users. PMID:19425002

  10. Capillary electrophoresis coupled with chloroform-acetonitrile extraction for rapid and highly selective determination of cysteine and homocysteine levels in human blood plasma and urine.

    PubMed

    Ivanov, Alexander Vladimirovich; Bulgakova, Polina Olegovna; Virus, Edward Danielevich; Kruglova, Maria Petrovna; Alexandrin, Valery Vasil'evich; Gadieva, Viktoriya Aleksandrovna; Luzyanin, Boris Petrovich; Kushlinskii, Nikolai Evgen'evich; Fedoseev, Anatolij Nikolaevich; Kubatiev, Aslan Amirkhanovich

    2017-10-01

    A rapid and selective method has been developed for highly sensitive determination of total cysteine and homocysteine levels in human blood plasma and urine by capillary electrophoresis (CE) coupled with liquid-liquid extraction. Analytes were first derivatized with 1,1'-thiocarbonyldiimidazole and then samples were purified by chloroform-ACN extraction. Electrophoretic separation was performed using 0.1 M phosphate with 30 mM triethanolamine, pH 2, containing 25 μM CTAB, 2.5 μM SDS, and 2.5% polyethylene glycol 600. Samples were injected into the capillary (with total length 32 cm and 50 μm id) at 2250 mbar*s and subsequent injection was performed for 30 s with 0.5 M KОН. The total analysis time was less than 9 min, accuracy was 98%, and precision was <2.6%. The LOD was 0.2 μM for homocysteine and 0.5 μM for cysteine. The use of liquid-liquid extraction allowed the precision and sensitivity of the CE method to be significantly increased. The validated method was applied to determine total cysteine and homocysteine content in human blood plasma and urine samples obtained from healthy volunteers and patients with kidney disorders. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. An analytical model for enantioseparation process in capillary electrophoresis

    NASA Astrophysics Data System (ADS)

    Ranzuglia, G. A.; Manzi, S. J.; Gomez, M. R.; Belardinelli, R. E.; Pereyra, V. D.

    2017-12-01

    An analytical model to explain the mobilities of enantiomer binary mixture in capillary electrophoresis experiment is proposed. The model consists in a set of kinetic equations describing the evolution of the populations of molecules involved in the enantioseparation process in capillary electrophoresis (CE) is proposed. These equations take into account the asymmetric driven migration of enantiomer molecules, chiral selector and the temporary diastomeric complexes, which are the products of the reversible reaction between the enantiomers and the chiral selector. The solution of these equations gives the spatial and temporal distribution of each species in the capillary, reproducing a typical signal of the electropherogram. The mobility, μ, of each specie is obtained by the position of the maximum (main peak) of their respective distributions. Thereby, the apparent electrophoretic mobility difference, Δμ, as a function of chiral selector concentration, [ C ] , can be measured. The behaviour of Δμ versus [ C ] is compared with the phenomenological model introduced by Wren and Rowe in J. Chromatography 1992, 603, 235. To test the analytical model, a capillary electrophoresis experiment for the enantiomeric separation of the (±)-chlorpheniramine β-cyclodextrin (β-CD) system is used. These data, as well as, other obtained from literature are in closed agreement with those obtained by the model. All these results are also corroborate by kinetic Monte Carlo simulation.

  12. Discrimination of non-explosive and explosive samples through nitrocellulose fingerprints obtained by capillary electrophoresis.

    PubMed

    Fernández de la Ossa, Ma Ángeles; Ortega-Ojeda, Fernando; García-Ruiz, Carmen

    2013-08-09

    This work is focused on a novel procedure to discriminate nitrocellulose-based samples with non-explosive and explosive properties. The nitrocellulose study has been scarcely approached in the literature due to its special polymeric properties such as its high molar mass and complex chemical and structural characteristics. These properties require the nitrocellulose analysis to be performed by using a few organic solvents and in consequence, they limit the number of adequate analytical techniques for its study. In terms of identification of pre-blast explosives, mass spectrometry is one of the most preferred technique because it allows to obtain structural information. However, it has never been used to analyze polymeric nitrocellulose. In this study, the differentiation of non-explosive and explosive samples through nitrocellulose fingerprints obtained by capillary electrophoresis was investigated. A batch of 30 different smokeless gunpowders and 23 different everyday products were pulverized, derivatized with a fluorescent agent and analyzed by capillary electrophoresis with laser-induced fluorescence detection. Since this methodology is specific to d-glucopyranose derivatives (cellulosic and related compounds), and paper samples could be easily found in explosion scenes, 11 different paper samples were also included in the study as potential interference samples. In order to discriminate among samples, multivariate analysis (principal component analysis and soft independent modeling of class analogy) was applied to the obtained electrophoretic profiles. To the best of our knowledge, this represents the first study that achieve a successful discrimination between non-explosive and explosive nitrocellulose-based samples, as well as potential cellulose interference samples, and posterior classification of unknown samples into their corresponding groups using CE-LIF and chemometric tools. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Automatic and integrated micro-enzyme assay (AIμEA) platform for highly sensitive thrombin analysis via an engineered fluorescence protein-functionalized monolithic capillary column.

    PubMed

    Lin, Lihua; Liu, Shengquan; Nie, Zhou; Chen, Yingzhuang; Lei, Chunyang; Wang, Zhen; Yin, Chao; Hu, Huiping; Huang, Yan; Yao, Shouzhuo

    2015-04-21

    Nowadays, large-scale screening for enzyme discovery, engineering, and drug discovery processes require simple, fast, and sensitive enzyme activity assay platforms with high integration and potential for high-throughput detection. Herein, a novel automatic and integrated micro-enzyme assay (AIμEA) platform was proposed based on a unique microreaction system fabricated by a engineered green fluorescence protein (GFP)-functionalized monolithic capillary column, with thrombin as an example. The recombinant GFP probe was rationally engineered to possess a His-tag and a substrate sequence of thrombin, which enable it to be immobilized on the monolith via metal affinity binding, and to be released after thrombin digestion. Combined with capillary electrophoresis-laser-induced fluorescence (CE-LIF), all the procedures, including thrombin injection, online enzymatic digestion in the microreaction system, and label-free detection of the released GFP, were integrated in a single electrophoretic process. By taking advantage of the ultrahigh loading capacity of the AIμEA platform and the CE automatic programming setup, one microreaction column was sufficient for many times digestion without replacement. The novel microreaction system showed significantly enhanced catalytic efficiency, about 30 fold higher than that of the equivalent bulk reaction. Accordingly, the AIμEA platform was highly sensitive with a limit of detection down to 1 pM of thrombin. Moreover, the AIμEA platform was robust and reliable to detect thrombin in human serum samples and its inhibition by hirudin. Hence, this AIμEA platform exhibits great potential for high-throughput analysis in future biological application, disease diagnostics, and drug screening.

  14. Electrophoretic separator for purifying biologicals

    NASA Technical Reports Server (NTRS)

    1976-01-01

    This technique separates a single narrow zone of sample mixture in an electrolyte medium into many zones containing a single component of the mixture and electrolyte between them. Since the densities of the separated zones generally differ from that of the intervening medium, such systems are gravitationally unstable and stabilization is required. The various techniques for stabilization include using the capillary space provided by thin films, the interstices of solid material such as filter paper and a variety of gel-forming substances.

  15. A simple and rapid electrophoretic method to characterize simple phenols, lignans, complex phenols, phenolic acids, and flavonoids in extra-virgin olive oil.

    PubMed

    Carrasco-Pancorbo, Alegria; Gómez-Caravaca, Ana Maria; Cerretani, Lorenzo; Bendini, Alessandra; Segura-Carretero, Antonio; Fernández-Gutiérrez, Alberto

    2006-09-01

    We have devised a simple and rapid capillary electrophoretic method which provides the analyst with a useful tool for the characterization of the polyphenolic fraction of extra-virgin olive oil. This method that uses a capillary with 50 microm id and a total length of 47 cm (40 cm to the detector) with a detection window of 100 x 200 microm, and a buffer solution containing 45 mM of sodium tetraborate pH 9.3 offers valuable information about all the families of compounds present in the polar fraction of the olive oil. The detection was carried out by UV absorption at 200, 240, 280, and 330 nm in order to facilitate the identification of the compounds. Concretely, the method permits the identification of simple phenols, lignans, complex phenols (isomeric forms of secoiridoids), phenolic acids, and flavonoids in the SPE-Diol extracts from extra-virgin olive oil in a short time (less than 10 min) and provides a satisfactory resolution. Peak identification was done by comparing both migration time and spectral data obtained from olive oil samples and standards (commercial or isolated (by HPLC-MS) standards), with spiked methanol-water extracts of olive oil with HPLC-collected compounds and commercially available standards at several concentration levels, studying the information of the electropherograms obtained at several wavelengths and also using the information previously reported.

  16. Chemical vapor deposition of aminopropyl silanes in microfluidic channels for highly efficient microchip capillary electrophoresis-electrospray ionization-mass spectrometry.

    PubMed

    Batz, Nicholas G; Mellors, J Scott; Alarie, Jean Pierre; Ramsey, J Michael

    2014-04-01

    We describe a chemical vapor deposition (CVD) method for the surface modification of glass microfluidic devices designed to perform electrophoretic separations of cationic species. The microfluidic channel surfaces were modified using aminopropyl silane reagents. Coating homogeneity was inferred by precise measurement of the separation efficiency and electroosmotic mobility for multiple microfluidic devices. Devices coated with (3-aminopropyl)di-isopropylethoxysilane (APDIPES) yielded near diffusion-limited separations and exhibited little change in electroosmotic mobility between pH 2.8 and pH 7.5. We further evaluated the temporal stability of both APDIPES and (3-aminopropyl)triethoxysilane (APTES) coatings when stored for a total of 1 week under vacuum at 4 °C or filled with pH 2.8 background electrolyte at room temperature. Measurements of electroosmotic flow (EOF) and separation efficiency during this time confirmed that both coatings were stable under both conditions. Microfluidic devices with a 23 cm long, serpentine electrophoretic separation channel and integrated nanoelectrospray ionization emitter were CVD coated with APDIPES and used for capillary electrophoresis (CE)-electrospray ionization (ESI)-mass spectrometry (MS) of peptides and proteins. Peptide separations were fast and highly efficient, yielding theoretical plate counts over 600,000 and a peak capacity of 64 in less than 90 s. Intact protein separations using these devices yielded Gaussian peak profiles with separation efficiencies between 100,000 and 400,000 theoretical plates.

  17. Application of antibiotics as chiral selectors for capillary electrophoretic enantioseparation of pharmaceuticals: a review.

    PubMed

    Dixit, Shuchi; Park, Jung Hag

    2014-01-01

    Recent years have witnessed several new trends in chiral separation, for example, the enantiorecognition ability of several new antibiotics has been explored using capillary electrophoresis (CE) prior to HPLC; antibiotics have been employed as chiral selectors (CSs) in a nonaqueous CE (NACE) mode; and several new detection techniques (namely, capacitively coupled contactless conductivity detection) have been used in combination with CE for quantification of enantiomers. On account of these emerging trends, this article aims to review the application of various classes of antibiotics for CE enantioseparation of pharmaceuticals. A detailed account of the basic factors affecting enantioseparation, certain limitations of antibiotics as CSs and strategies to mitigate them, and advantages of NACE while using antibiotics as CSs has also been presented. Copyright © 2013 John Wiley & Sons, Ltd.

  18. Determination of psilocybin in Psilocybe semilanceata by capillary zone electrophoresis.

    PubMed

    Pedersen-Bjergaard, S; Sannes, E; Rasmussen, K E; Tønnesen, F

    1997-07-04

    A capillary zone electrophoretic (CZE) method was developed for the rapid determination of psilocybin in Psilocybe semilanceata. Following a simple two step extraction with 3.0+2.0 ml methanol, the hallucinogenic compound was effectively separated from matrix components by CZE utilizing a 10 mM borate-phosphate running buffer adjusted to pH 11.5. The identity of psilocybin was confirmed by migration time information and by UV spectra, while quantitation was accomplished utilizing barbital as internal standard. The calibration curve for psilocybin was linear within 0.01-1 mg/ml, while intra-day and inter-day variations of quantitative data were 0.5 and 2.5% R.S.D., respectively. In addition to psilocybin, the method was also suitable for the determination of the structurally related compound baeocystin.

  19. Analysis of aromatic aldehydes in brandy and wine by high-performance capillary electrophoresis.

    PubMed

    Panossian, A; Mamikonyan, G; Torosyan, M; Gabrielyan, E; Mkhitaryan, S

    2001-09-01

    A new method of analysis of vanillin, syringaldehyde, coniferaldehyde, and sinapaldehyde in brandy and wine by high-performance capillary electrophoresis is described. Electrophoretic mobility of these compounds is achieved by a borate buffer at pH 9.3. At this pH, the sensitivity of UV detection of these phenolic aldehydes also increases. UV absorptions at 348, 362, 404, and 422 nm were selected for monitoring vanillin, syringaldehyde, coniferaldehyde, and sinapaldehyde, respectively. This procedure was performed simultaneously during one run using a diode array detector. Samples of brandy or wine were analyzed directly without concentration, extraction, or any other preliminary treatment of the test sample. The limits of detection were found to be 0.275, 0.1425, 0.1475, and 0.1975 ppm for syringaldehyde, coniferaldehyde, sinapaldehyde, and vanillin, respectively, which is acceptable for analysis of both brandy and wine aged in oak barrels. The method has been shown to be linear in a range from 0.3 to 57 mg/L. Recoveries ranged between 99.9% and 107.7% for all of the compounds tested. Repeatability and reproducibility of the method were high. The relative standard deviation was consequently approximately 3% and also between 4.47% and 6.89% for all tested compounds. The method is useful for the identification of counterfeit brandy, which is easy to recognize by the absence of sinapaldehyde, syringaldehyde, and coniferaldehyde, which are not detectable in false brandy.

  20. Coarse-grained model of conformation-dependent electrophoretic mobility and its influence on DNA dynamics

    NASA Astrophysics Data System (ADS)

    Pandey, Harsh; Underhill, Patrick T.

    2015-11-01

    The electrophoretic mobility of molecules such as λ -DNA depends on the conformation of the molecule. It has been shown that electrohydrodynamic interactions between parts of the molecule lead to a mobility that depends on conformation and can explain some experimental observations. We have developed a new coarse-grained model that incorporates these changes of mobility into a bead-spring chain model. Brownian dynamics simulations have been performed using this model. The model reproduces the cross-stream migration that occurs in capillary electrophoresis when pressure-driven flow is applied parallel or antiparallel to the electric field. The model also reproduces the change of mobility when the molecule is stretched significantly in an extensional field. We find that the conformation-dependent mobility can lead to a new type of unraveling of the molecule in strong fields. This occurs when different parts of the molecule have different mobilities and the electric field is large.

  1. Local electrophoretic deposition using a nanopipette for micropillar fabrication

    NASA Astrophysics Data System (ADS)

    Iwata, Futoshi; Metoki, Junya

    2017-12-01

    A novel and simple technique was developed for the fabrication of micropillars using a nanopipette that is a tapered glass capillary with a micrometer-sized aperture at the tip. The nanopipette was filled with a colloidal solution that included metal nanoparticles. Its tip was put in contact with a substrate, and the substrate was moved downward for continuous deposition of the metal colloidal solution to form micropillars. To improve fabrication reproducibility, the amount of Au colloidal solution deposited was controlled by a feedback loop that maintained a predefined constant current during electrophoretic deposition. The stiffness of the fabricated micropillars was evaluated by applying a loading force using a microcantilever under scanning electron microscopy. The Young’s modulus of the fabricated pillars was measured to be in the range of 7.7-14.8 GPa, depending on the fabrication parameters of the predefined current and fabrication speed.

  2. A low-molecular-weight galactofucan from the seaweed, Spatoglossum schröederi, binds fibronectin and inhibits capillary-like tube formation in vitro.

    PubMed

    Menezes, Maira Maria; Nobre, Leonardo Thiago Duarte Barreto; Rossi, Gustavo Rodrigues; Almeida-Lima, Jailma; Melo-Silveira, Raniere Fagundes; Franco, Celia Regina Cavichiolo; Trindade, Edvaldo Silva; Nader, Helena Bonciani; Rocha, Hugo Alexandre Oliveira

    2018-05-01

    A low-molecular-weight (LMW) heterofucan (designated fucan B) was obtained from the brown seaweed, Spatoglossum schröederi, and its activity as an inhibitor of capillary-like tube formation by endothelial cells (ECs) was analyzed. Chemical, infrared and electrophoretic analyses confirmed the identity of fucan B. In contrast to other LMW fucans, fucan B (0.012-0.1 mg/mL) inhibited ECs capillary-like tube formation in a concentration-dependent manner. In addition, fucan B (0.01-0.05 mg/mL) did not affect ECs proliferation. Fucan B also inhibited ECs migration on a fibronectin-coated surface, but not on laminin- or collagen-coated surfaces. Biotinylated fucan B was used as a probe to identify its localization. Confocal microscopy experiments revealed that biotinylated fucan did not bind to the cell surface, but rather only to fibronectin. Our findings suggest that fucan B inhibits ECs capillary-like tube formation and migration by binding directly to fibronectin and blocking fibronectin sites recognized by cell surface ligands. However, further studies are needed to evaluate the in vivo effects of fucan B. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Method development and qualification of capillary zone electrophoresis for investigation of therapeutic monoclonal antibody quality.

    PubMed

    Suba, Dávid; Urbányi, Zoltán; Salgó, András

    2016-10-01

    Capillary electrophoresis techniques are widely used in the analytical biotechnology. Different electrophoretic techniques are very adequate tools to monitor size-and charge heterogenities of protein drugs. Method descriptions and development studies of capillary zone electrophoresis (CZE) have been described in literature. Most of them are performed based on the classical one-factor-at-time (OFAT) approach. In this study a very simple method development approach is described for capillary zone electrophoresis: a "two-phase-four-step" approach is introduced which allows a rapid, iterative method development process and can be a good platform for CZE method. In every step the current analytical target profile and an appropriate control strategy were established to monitor the current stage of development. A very good platform was established to investigate intact and digested protein samples. Commercially available monoclonal antibody was chosen as model protein for the method development study. The CZE method was qualificated after the development process and the results were presented. The analytical system stability was represented by the calculated RSD% value of area percentage and migration time of the selected peaks (<0.8% and <5%) during the intermediate precision investigation. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Sensitive monitoring of iodine species in sea water using capillary electrophoresis: vertical profiles of dissolved iodine in the Pacific Ocean.

    PubMed

    Huang, Zhuo; Ito, Kazuaki; Morita, Isamu; Yokota, Kuriko; Fukushi, Keiichi; Timerbaev, Andrei R; Watanabe, Shuichi; Hirokawa, Takeshi

    2005-08-01

    Using a novel high-sensitivity capillary electrophoretic method, vertical distributions of iodate, iodide, total inorganic iodine, dissolved organic iodine and total iodine in the North Pacific Ocean (0-5500 m) were determined without any sample pre-treatment other than UV irradiation before total iodine analysis. An extensive set of data demonstrated that the iodine behaviour in the ocean water collected during a cruise in the North Pacific Ocean in February-March 2003 was not conservative but correlated with variations in concentrations of dissolved oxygen and nutrient elements such as silicon, nitrogen and phosphorus. This suggests that the vertical distribution of iodine is associated with biological activities. The dissolved organic iodine was found in the euphotic zone in accord with observations elsewhere in the oceans. The vertical profile of dissolved organic iodine also appears to be related to biogeochemical activity. The concentrations of all measured iodine species vary noticeably above 1000 m but only minor latitudinal changes occur below 1000 m and slight vertical alterations can be observed below 2400 m. These findings are thought to reflect the stratification of nutrients and iodine species with different biological activities in the water column.

  5. Chiral capillary electrophoresis with UV-excited fluorescence detection for the enantioselective analysis of 9-fluorenylmethoxycarbonyl-derivatized amino acids.

    PubMed

    Prior, Amir; Coliva, Giulia; de Jong, Gerhardus J; Somsen, Govert W

    2018-05-29

    The potential of capillary electrophoresis (CE) with ultraviolet (UV)-excited fluorescence detection for sensitive chiral analysis of amino acids (AAs) was investigated. DL-AAs were derivatized with 9-fluorenylmethoxycarbonyl chloride (FMOC)-Cl to allow their fluorescence detection and enhance enantioseparation. Fluorescence detection was achieved employing optical fibers, leading UV excitation light (< 300 nm) from a Xe-Hg lamp to the capillary window, and fluorescence emission to a spectrograph equipped with a charge-coupled device (CCD). Signal averaging over time and emission wavelength intervals was carried out to improve the signal-to-noise ratio of the FMOC-AAs. A background electrolyte (BGE) of 40 mM sodium tetraborate (pH 9.5), containing 15% isopropanol (v/v), 30 mM sodium dodecyl sulfate (SDS), and 30 mM β-cyclodextrin (β-CD), was found optimal for AA chemo- and enantioseparation. Enantioresolutions of 1.0 or higher were achieved for 16 proteinogenic DL-AAs. Limits of detection (LODs) were in the 10-100-nM range (injected concentration) for the D-AA enantiomers, except for FMOC-D-tryptophan (536 nM) which showed intramolecular fluorescence quenching. Linearity (R 2  > 0.997) and repeatability for peak height (relative standard deviations (RSDs) < 7.0%; n = 5) and electrophoretic mobility (RSDs < 0.6%; n = 5) of individual AA enantiomers were established for chiral analysis of DL-AA mixtures. The applicability of the method was investigated by the analysis of cerebrospinal fluid (CSF). Next to L-AAs, endogenous levels of D-glutamine and D-aspartic acid could be measured in CSF revealing enantiomeric ratios of 0.35 and 19.6%, respectively. This indicates the method's potential for the analysis of low concentrations of D-AAs in presence of abundant L-AAs.

  6. On-line sequential injection-capillary electrophoresis for near-real-time monitoring of extracellular lactate in cell culture flasks.

    PubMed

    Alhusban, Ala A; Gaudry, Adam J; Breadmore, Michael C; Gueven, Nuri; Guijt, Rosanne M

    2014-01-03

    Cell culture has replaced many in vivo studies because of ethical and regulatory measures as well as the possibility of increased throughput. Analytical assays to determine (bio)chemical changes are often based on end-point measurements rather than on a series of sequential determinations. The purpose of this work is to develop an analytical system for monitoring cell culture based on sequential injection-capillary electrophoresis (SI-CE) with capacitively coupled contactless conductivity detection (C(4)D). The system was applied for monitoring lactate production, an important metabolic indicator, during mammalian cell culture. Using a background electrolyte consisting of 25mM tris(hydroxymethyl)aminomethane, 35mM cyclohexyl-2-aminoethanesulfonic acid with 0.02% poly(ethyleneimine) (PEI) at pH 8.65 and a multilayer polymer coated capillary, lactate could be resolved from other compounds present in media with relative standard deviations 0.07% for intraday electrophoretic mobility and an analysis time of less than 10min. Using the human embryonic kidney cell line HEK293, lactate concentrations in the cell culture medium were measured every 20min over 3 days, requiring only 8.73μL of sample per run. Combining simplicity, portability, automation, high sample throughput, low limits of detection, low sample consumption and the ability to up- and outscale, this new methodology represents a promising technique for near real-time monitoring of chemical changes in diverse cell culture applications. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. nES GEMMA Analysis of Lectins and Their Interactions with Glycoproteins - Separation, Detection, and Sampling of Noncovalent Biospecific Complexes

    NASA Astrophysics Data System (ADS)

    Engel, Nicole Y.; Weiss, Victor U.; Marchetti-Deschmann, Martina; Allmaier, Günter

    2017-01-01

    In order to better understand biological events, lectin-glycoprotein interactions are of interest. The possibility to gather more information than the mere positive or negative response for interactions brought mass spectrometry into the center of many research fields. The presented work shows the potential of a nano-electrospray gas-phase electrophoretic mobility molecular analyzer (nES GEMMA) to detect weak, noncovalent, biospecific interactions besides still unbound glycoproteins and unreacted lectins without prior liquid phase separation. First results for Sambucus nigra agglutinin, concanavalin A, and wheat germ agglutinin and their retained noncovalent interactions with glycoproteins in the gas phase are presented. Electrophoretic mobility diameters (EMDs) were obtained by nES GEMMA for all interaction partners correlating very well with molecular masses determined by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) of the individual molecules. Moreover, EMDs measured for the lectin-glycoprotein complexes were in good accordance with theoretically calculated mass values. Special focus was laid on complex formation for different lectin concentrations and binding specificities to evaluate the method with respect to results obtained in the liquid phase. The latter was addressed by capillary electrophoresis on-a-chip (CE-on-a-chip). Of exceptional interest was the fact that the formed complexes could be sampled according to their size onto nitrocellulose membranes after gas-phase separation. Subsequent immunological investigation further proved that the collected complex actually retained its native structure throughout nES GEMMA analysis and sampling.

  8. Classification of Spanish white wines using their electrophoretic profiles obtained by capillary zone electrophoresis with amperometric detection.

    PubMed

    Arribas, Alberto Sánchez; Martínez-Fernández, Marta; Moreno, Mónica; Bermejo, Esperanza; Zapardiel, Antonio; Chicharro, Manuel

    2014-06-01

    A method was developed for the simultaneous detection of eight polyphenols (t-resveratrol, (+)-catechin, quercetin and p-coumaric, caffeic, sinapic, ferulic, and gallic acids) by CZE with electrochemical detection. Separation of these polyphenols was achieved within 25 min using a 200 mM borate buffer (pH 9.4) containing 10% methanol as separation electrolyte. Amperometric detection of polyphenols was carried out with a glassy carbon electrode (GCE) modified with a multiwalled carbon nanotubes (CNT) layer obtained from a dispersion of CNT in polyethylenimine. The excellent electrochemical properties of this modified electrode allowed the detection and quantification of the selected polyphenols in white wines without any pretreatment step, showing remarkable signal stability despite the presence of potential fouling substances in wine. The electrophoretic profiles of white wines, obtained using this methodology, have proven to be useful for the classification of these wines by means of chemometric multivariate techniques. Principal component analysis and discriminant analysis allowed accurate classification of wine samples on the basis of their grape varietal (verdejo and airén) using the information contained in selected zones of the electropherogram. The utility of the proposed CZE methodology based on the electrochemical response of CNT-modified electrodes appears to be promising in the field of wine industry and it is expected to be successfully extended to classification of a wider range of wines made of other grape varietals. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Quantitative analysis of ribosome–mRNA complexes at different translation stages

    PubMed Central

    Shirokikh, Nikolay E.; Alkalaeva, Elena Z.; Vassilenko, Konstantin S.; Afonina, Zhanna A.; Alekhina, Olga M.; Kisselev, Lev L.; Spirin, Alexander S.

    2010-01-01

    Inhibition of primer extension by ribosome–mRNA complexes (toeprinting) is a proven and powerful technique for studying mechanisms of mRNA translation. Here we have assayed an advanced toeprinting approach that employs fluorescently labeled DNA primers, followed by capillary electrophoresis utilizing standard instruments for sequencing and fragment analysis. We demonstrate that this improved technique is not merely fast and cost-effective, but also brings the primer extension inhibition method up to the next level. The electrophoretic pattern of the primer extension reaction can be characterized with a precision unattainable by the common toeprint analysis utilizing radioactive isotopes. This method allows us to detect and quantify stable ribosomal complexes at all stages of translation, including initiation, elongation and termination, generated during the complete translation process in both the in vitro reconstituted translation system and the cell lysate. We also point out the unique advantages of this new methodology, including the ability to assay sites of the ribosomal complex assembly on several mRNA species in the same reaction mixture. PMID:19910372

  10. Recent advances in capillary electrophoresis separation of monosaccharides, oligosaccharides, and polysaccharides.

    PubMed

    Mantovani, Veronica; Galeotti, Fabio; Maccari, Francesca; Volpi, Nicola

    2018-01-01

    This article illustrates the basis and applications of methodologies for the analysis of simple and complex carbohydrates by means of CE. After a description of the most common and novel approaches useful for the analysis and characterization of carbohydrates, this review covers the recent advances in CE separation of monosaccharides, oligosaccharides, and polysaccharides. Various CE techniques are also illustrated for the study of carbohydrates derived from complex glyco-derivatives such as glycoproteins and glycolipids, essential for biopharmaceutical and glycoproteomics applications as well as for biomarker detection. Most glycans have no significant UV absorption, and derivatization with fluorophore groups prior to separation usually results in higher sensitivity and an improved electrophoretic profile. We also discuss the recent applications and separations by CE of derivatized simple and more complex carbohydrates with different chromophoric active tags. Overall, this review aims to give an overview of the most recent state-of-the-art techniques used in carbohydrate analysis by CE. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Comparative Validation of the Determination of Sofosbuvir in Pharmaceuticals by Several Inexpensive Ecofriendly Chromatographic, Electrophoretic, and Spectrophotometric Methods.

    PubMed

    El-Yazbi, Amira F

    2017-07-01

    Sofosbuvir (SOFO) was approved by the U.S. Food and Drug Administration in 2013 for the treatment of hepatitis C virus infection with enhanced antiviral potency compared with earlier analogs. Notwithstanding, all current editions of the pharmacopeias still do not present any analytical methods for the quantification of SOFO. Thus, rapid, simple, and ecofriendly methods for the routine analysis of commercial formulations of SOFO are desirable. In this study, five accurate methods for the determination of SOFO in pharmaceutical tablets were developed and validated. These methods include HPLC, capillary zone electrophoresis, HPTLC, and UV spectrophotometric and derivative spectrometry methods. The proposed methods proved to be rapid, simple, sensitive, selective, and accurate analytical procedures that were suitable for the reliable determination of SOFO in pharmaceutical tablets. An analysis of variance test with P-value > 0.05 confirmed that there were no significant differences between the proposed assays. Thus, any of these methods can be used for the routine analysis of SOFO in commercial tablets.

  12. Differentiation of modern and ancient varieties of common wheat by quantitative capillary electrophoretic profile of phenolic acids.

    PubMed

    Gotti, Roberto; Amadesi, Elisa; Fiori, Jessica; Bosi, Sara; Bregola, Valeria; Marotti, Ilaria; Dinelli, Giovanni

    2018-01-12

    Phenolic compounds have received great attention among the health promoting phytochemicals in common wheat (Triticum aestivum L.), mainly because of their strong antioxidant properties. In the present study a simple Capillary Zone Electrophoresis (CZE) method with UV detection was optimized and validated for the quantitation of six of the most important phenolic acids in whole grain i.e., sinapic, ferulic, syringic, p-coumaric, vanillic and p-hydroxybenzoic acid. The separation was achieved in a running buffer composed of sodium phosphate solution (50 mM) in water/methanol 80:20 (v/v) at pH 6.0 and using a fused-silica capillary at the temperature of 30 °C under application of 27 kV. By means of diode array detector, and made possible by the favorable characteristic UV spectra, the quantitation of the solutes was carried out at 200, 220 and 300 nm, in the complex matrices represented by the soluble and bound fractions of wheat flours. The validation parameters of the method i.e., linearity, sensitivity, precision, accuracy and robustness were in line with those obtained by consolidated separation techniques applied for the same purposes (e.g., HPLC-UV), with a significant advantage in term of analysis time (less than 12 min). Ten varieties of soft wheat (five modern Italian and five old Italian genotypes) were analysed and the data were subjected to Principal Components Analysis (PCA). Interestingly, significant differences of the quantitative phenolic acids profile were observed between the modern and the ancient genotypes, with the latter showing higher amount of the main represented phenolic acids. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Speciation of mercury by hydrostatically modified electroosmotic flow capillary electrophoresis coupled with volatile species generation atomic fluorescence spectrometry.

    PubMed

    Yan, Xiu-Ping; Yin, Xue-Bo; Jiang, Dong-Qing; He, Xi-Wen

    2003-04-01

    A novel method for speciation analysis of mercury was developed by on-line hyphenating capillary electrophoresis (CE) with atomic fluorescence spectrometry (AFS). The four mercury species of inorganic mercury Hg(II), methymercury MeHg(I), ethylmercury EtHg(I), and phenylmercury PhHg(I) were separated as mercury-cysteine complexes by CE in a 50-cm x 100-microm-i.d. fused-silica capillary at 15 kV and using a mixture of 100 mmol L(-1) of boric acid and 12% v/v methanol (pH 9.1) as electrolyte. A novel technique, hydrostatically modified electroosmotic flow (HSMEOF) in which the electroosmotic flow (EOF) was modified by applying hydrostatical pressure opposite to the direction of EOF was used to improve resolution. A volatile species generation technique was used to convert the mercury species into their respective volatile species. A newly developed CE-AFS interface was employed to provide an electrical connection for stable electrophoretic separations and to allow on-line volatile species formation. The generated volatile species were on-line detected with AFS. The precisions (RSD, n = 5) were in the range of 1.9-2.5% for migration time, 1.8-6.3% for peak area response, and 2.3-6.1% for peak height response for the four mercury species. The detection limits ranged from 6.8 to 16.5 microg L(-1) (as Hg). The recoveries of the four mercury species in the water samples were in the range of 86.6-111%. The developed technique was successfully applied to speciation analysis of mercury in a certified reference material (DORM-2, dogfish muscle).

  14. Sub-minute method for simultaneous determination of aspartame, cyclamate, acesulfame-K and saccharin in food and pharmaceutical samples by capillary zone electrophoresis.

    PubMed

    Vistuba, Jacqueline Pereira; Dolzan, Maressa Danielli; Vitali, Luciano; de Oliveira, Marcone Augusto Leal; Micke, Gustavo Amadeu

    2015-05-29

    This paper reports the development of a sub-minute separation method by capillary zone electrophoresis for the determination of aspartame, cyclamate, acesulfame-K and saccharin in food products and pharmaceutical samples. Separations were performed in a fused uncoated silica capillary with UV detection at 220nm. Samples and standards were injected hydrodynamically using the short-end injection procedure. The electrophoretic system was operated under constant voltage of -30kV. The background electrolyte was composed of 45mmolL(-1) 2-amino-2-(hydroxymethyl)-1,3-propanediol and 15mmolL(-1) benzoic acid at pH 8.4. The separation time for all analytes was less than 1min. Evaluation of analytical parameters of the method showed good linearity (r(2)>0.9972), limit of detection of 3.3-6.4mgL(-1), intermediate precision better than 9.75% (peak area of sample) and recovery in the range of 91-117%. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Charge-based characterization of nanometric cationic bifunctional maghemite/silica core/shell particles by capillary zone electrophoresis.

    PubMed

    d'Orlyé, Fanny; Varenne, Anne; Georgelin, Thomas; Siaugue, Jean-Michel; Teste, Bruno; Descroix, Stéphanie; Gareil, Pierre

    2009-07-01

    In view of employing functionalized nanoparticles (NPs) in the context of an immunodiagnostic, aminated maghemite/silica core/shell particles were synthesized so as to be further coated with an antibody or an antigen via the amino groups at their surface. Different functionalization rates were obtained by coating these maghemite/silica core/shell particles with 3-(aminopropyl)triethoxysilane and 2-[methoxy(polyethyleneoxy)propyl]-trimethoxysilane at different molar ratios. Adequate analytical performances with CE coupled with UV-visible detection were obtained through semi-permanent capillary coating with didodecyldimethyl-ammonium bromide, thus preventing particle adsorption. First, the influence of experimental conditions such as electric field strength, injected particle amount as well as electrolyte ionic strength and pH, was evaluated. A charge-dependent electrophoretic mobility was evidenced and the separation selectivity was tuned according to electrolyte ionic strength and pH. The best resolutions were obtained at pH 8.0, high ionic strength (ca. 100 mM), and low total particle volume fraction (ca. 0.055%), thus eliminating interference effects between different particle populations in mixtures. A protocol derived from Kaiser's original description was performed for quantitation of the primary amino groups attached onto the NP surface. Thereafter a correlation between particle electrophoretic mobility and the density of amino groups at their surface was established. Eventually, CE proved to be an easy, fast, and reliable method for the determination of NP effective surface charge density.

  16. Fast evaluation of enantioselective drug metabolism by electrophoretically mediated microanalysis: application to fluoxetine metabolism by CYP2D6.

    PubMed

    Asensi-Bernardi, Lucía; Martín-Biosca, Yolanda; Escuder-Gilabert, Laura; Sagrado, Salvador; Medina-Hernández, María José

    2013-12-01

    In this work, a capillary electrophoretic methodology for the enantioselective in vitro evaluation of drugs metabolism is applied to the evaluation of fluoxetine (FLX) metabolism by cytochrome 2D6 (CYP2D6). This methodology comprises the in-capillary enzymatic reaction and the chiral separation of FLX and its major metabolite, norfluoxetine enantiomers employing highly sulfated β-CD and the partial filling technique. The methodology employed in this work is a fast way to obtain a first approach of the enantioselective in vitro metabolism of racemic drugs, with the additional advantage of an extremely low consumption of enzymes, CDs and all the reagents involved in the process. Michaelis-Menten kinetic parameters (Km and Vmax ) for the metabolism of FLX enantiomers by CYP2D6 have been estimated by nonlinear fitting of experimental data to the Michaelis-Menten equation. Km values have been found to be 30 ± 3 μM for S-FLX and 39 ± 5 μM for R-FLX. Vmax estimations were 28.6 ± 1.2 and 34 ± 2 pmol·min(-1) ·(pmol CYP)(-1) for S- and R-FLX, respectively. Similar results were obtained using a single enantiomer (R-FLX), indicating that the use of the racemate is a good option for obtaining enantioselective estimations. The results obtained show a slight enantioselectivity in favor of R-FLX. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Method development of enantiomer separations by affinity capillary electrophoresis, cyclodextrin electrokinetic chromatography and capillary electrophoresis-mass spectrometry.

    PubMed

    Tanaka, Yoshihide

    2002-07-01

    Capillary electrophoresis (CE) has become a powerful tool for enantiomer separations during the last decade. Since 1993, the author has investigated enantiomer separations by affinity capillary electrophoresis (affinity CE) with some proteins and by cyclodextrin electrokinetic chromatography (CDEKC) with some charged cyclodextrins (CDs). Many successful enantiomer separations are demonstrated from our study in this review article. In the enantiomer separations by affinity CE, the deterioration of detection sensitivity was observed under high concentration of the protein in running solutions. The partial filling technique was practically useful to solve the serious problem. It allowed operation at high protein concentrations, such as 500 mumol/L, without the detection problem. Charged CDs had several advantages for the enantiomer separations over neutral ones. Strong electrostatic interactions between a charged CD and oppositely charged analytes should be effective for the formation of the complex. A large difference in electrophoretic mobility between the free analyte and the inclusion complex should also enhance the enantiomeric resolution. In CE-mass spectrometry (CE-MS), the partial filling technique was applied to avoid the introduction of nonvolatile chiral selectors into the CE-MS interface. By replacing the nonvolatile electrolytes in the running buffer by volatile ones, the separation conditions employed in CE with the UV detection method could be transferred to CE-MS.

  18. Capillary electrophoretic enantioseparation of basic drugs using a new single-isomer cyclodextrin derivative and theoretical study of the chiral recognition mechanism.

    PubMed

    Liu, Yongjing; Deng, Miaoduo; Yu, Jia; Jiang, Zhen; Guo, Xingjie

    2016-05-01

    A novel single-isomer cyclodextrin derivative, heptakis {2,6-di-O-[3-(1,3-dicarboxyl propylamino)-2-hydroxypropyl]}-β-cyclodextrin (glutamic acid-β-cyclodextrin) was synthesized and used as a chiral selector in capillary electrophoresis for the enantioseparation of 12 basic drugs, including terbutaline, clorprenaline, tulobuterol, clenbuterol, procaterol, carvedilol, econazole, miconazole, homatropine methyl bromide, brompheniramine, chlorpheniramine and pheniramine. The primary factors affecting separation efficiency, which include the background electrolyte pH, the concentration of glutamic acid-β-cyclodextrin and phosphate buffer concentration, were investigated. Satisfactory enantioseparations were obtained using an uncoated fused-silica capillary of 50 cm (effective length 40 cm) × 50 μm id with 120 mM phosphate buffer (pH 2.5-4.0) containing 0.5-4.5 mM glutamic acid-β-cyclodextrin as background electrolyte. A voltage of 20 kV was applied and the capillary temperature was kept at 20°C. The results proved that glutamic acid-β-cyclodextrin was an effective chiral selector for studied 12 basic drugs. Moreover, the possible chiral recognition mechanism of brompheniramine, chlorpheniramine and pheniramine on glutamic acid-β-cyclodextrin was investigated using the semi-empirical Parametric Method 3. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Analysis of subcellular sized particles. Capillary electrophoresis with post-column laser-induced fluorescence detection versus flow cytometry.

    PubMed

    Poe, Bobby G; Navratil, Marian; Arriaga, Edgar A

    2006-12-29

    Flow cytometry (FCM) and more recently capillary electrophoresis with post-column laser-induced fluorescence detection (CE-LIF) have both been used for subcellular particle analysis but their analytical performance has not been compared. In this work, we compare a commercial FCM with an in-house built CE-LIF instrument using fluorescently labeled microspheres and isolated mitochondria. As evidenced by the relative standard deviation (RSD) of the individual fluorescence intensities, FCM is two-fold better than CE-LIF for microspheres with > or =1.5 x 10(6) molecules of equivalent soluble fluorescein (MESF). However, FCM has a comparatively low signal-to-noise ratio (S/N) and high RSD for microspheres with <1.5 x 10(6) MESF. CE-LIF, on the other hand, produces S/N ratios that are >25 times higher than FCM for all the microspheres tested and a lower RSD for microspheres with <1.5 x 10(6) MESF. When 10-N-nonyl acridine orange (NAO)-labeled mitochondria are analyzed, the S/N ratios of both techniques are similar. This appears to result from photobleaching of NAO-labeled mitochondria as they are detected by the LIF detector of the CE-LIF instrument. Both techniques have a niche in subcellular analysis; FCM has the advantage of collecting data for thousands of particles quickly, whereas CE-LIF consumes less than a nanoliter of sample and provides the electrophoretic mobility for individual particles.

  20. Electrokinetic Sample Preconcentration and Hydrodynamic Sample Injection for Microchip Electrophoresis Using a Pneumatic Microvalve

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cong, Yongzheng; Katipamula, Shanta; Geng, Tao

    2016-02-01

    A microfluidic platform was developed to perform online electrokinetic sample preconcentration and rapid hydrodynamic sample injection for electrophoresis using a single microvalve. The PDMS microchip consists of a separation channel, a side channel for sample introduction, and a control channel which is used as a pneumatic microvalve aligned at the intersection of the two flow channels. The closed microvalve, created by multilayer soft lithography, can serve as a preconcentrator under an applied electric potential, enabling current to pass through while blocking bulk flow. Once analytes are concentrated, the valve is briefly opened and the stacked sample is pressure injected intomore » the separation channel for electrophoretic separation. Fluorescently labeled peptides were enriched by a factor of ~450 in 230 s. The performance of the platform was validated by the online preconcentration, injection and electrophoretic separation of fluorescently labeled peptides. This method enables both rapid analyte concentration and controlled injection volume for high sensitivity, high resolution capillary electrophoresis.« less

  1. Capillary electrophoretic determination of selected phenolic compounds in humic substances of well waters and fertilizers.

    PubMed

    Chen, Mei-Ying; Chang, Yan-Zin; Lu, Fung-Jou; Chen, Jian-Lian

    2010-01-01

    Humic substances (HS) from well waters, fertilizers, and synthetic phenolic polymers were characterized by elemental and UV-VIS spectroscopic analyses. Capillary zone electrophoresis (CZE) with UV absorption detection was used to analyze the lignin-derived phenolic distribution in the degradation residues after alkaline CuO oxidation of HS samples. Eleven phenols with p-acetyl, vanillyl and syringyl substituents were selected to optimize the CZE parameters. For well waters and fertilizers, the content of phenolic fragments was in agreement with the findings of the elemental and spectroscopic measurements. Additionally, parameters derived from the vanillic acid/vanilline, syringyl acid/syringaldehyde, p-hydroxyl/vanillyl and syringyl/vanillyl ratios matched analogous studies on dissolved organic matter from natural waters and on humic acids from terrestrial substances. The amount of phenolic monomer bonded within two synthetic HS polymers was found to be 25.9% protocatechuic acid and 71.3% gallic acid.

  2. Simultaneous identification of natural dyes in the collection of drawings and maps from The Royal Chancellery Archives in Granada (Spain) by CE.

    PubMed

    López-Montes, Ana; Blanc García, Rosario; Espejo, Teresa; Huertas-Perez, José F; Navalón, Alberto; Vílchez, José Luis

    2007-04-01

    A simple and rapid capillary electrophoretic method with UV detection (CE-UV) has been developed for the identification of five natural dyes namely, carmine, indigo, saffron, gamboge and Rubia tinctoria root. The separation was performed in a fused-silica capillary of 64.5 cm length and 50 microm id. The running buffer was 40 mM sodium tetraborate buffer solution (pH 9.25). The applied potential was 30 kV, the temperature was 25 degrees C and detections were performed at 196, 232, 252, 300 and 356 nm. The injections were under pressure of 50 mbar during 13 s. The method was applied to the identification of carminic acid, gambogic acid, crocetin, indigotin, alizarin and purpurin in the collection of drawings and maps at the Royal Chancellery Archives in Granada (Spain). The method was validated by using HPLC as a reference method.

  3. Thermoplastic microchannel fabrication using carbon dioxide laser ablation.

    PubMed

    Wang, Shau-Chun; Lee, Chia-Yu; Chen, Hsiao-Ping

    2006-04-14

    We report the procedures of machining microchannels on Vivak co-polyester thermoplastic substrates using a simple industrial CO(2) laser marker. To avoid overheating the substrates, we develop low-power marking techniques in nearly anaerobic environment. These procedures are able to machine microchannels at various aspect ratios. Either straight or serpent channel can be easily marked. Like the wire-embossed channel walls, the ablated channel surfaces become charged after alkaline hydrolysis treatment. Stable electroosmotic flow in the charged conduit is observed to be of the same order of magnitude as that in fused silica capillary. Typical dynamic coating protocols to alter the conduit surface properties are transferable to the ablated channels. The effects of buffer acidity on electroosmotic mobility in both bare and coated channels are similar to those in fused silica capillaries. Using video microscopy we also demonstrate that this device is useful in distinguishing the electrophoretic mobility of bare and latex particles from that of functionalized ones.

  4. Fast high-throughput method for the determination of acidity constants by capillary electrophoresis: I. Monoprotic weak acids and bases.

    PubMed

    Fuguet, Elisabet; Ràfols, Clara; Bosch, Elisabeth; Rosés, Martí

    2009-04-24

    A new and fast method to determine acidity constants of monoprotic weak acids and bases by capillary zone electrophoresis based on the use of an internal standard (compound of similar nature and acidity constant as the analyte) has been developed. This method requires only two electrophoretic runs for the determination of an acidity constant: a first one at a pH where both analyte and internal standard are totally ionized, and a second one at another pH where both are partially ionized. Furthermore, the method is not pH dependent, so an accurate measure of the pH of the buffer solutions is not needed. The acidity constants of several phenols and amines have been measured using internal standards of known pK(a), obtaining a mean deviation of 0.05 pH units compared to the literature values.

  5. Simultaneous separation of water- and fat-soluble vitamins in isocratic pressure-assisted capillary electrochromatography using a methacrylate-based monolithic column.

    PubMed

    Yamada, Hiroki; Kitagawa, Shinya; Ohtani, Hajime

    2013-06-01

    A method of simultaneous separation of water- and fat-soluble vitamins using pressure-assisted CEC with a methacrylate-based capillary monolithic column was developed. In the proposed method, water-soluble vitamins were mainly separated electrophoretically, while fat soluble-ones were separated chromatographically by the interaction with a methacrylate-based monolith. A mixture of six water-soluble and four fat-soluble vitamins was separated simultaneously within 20 min with an isocratic elution using 1 M formic acid (pH 1.9)/acetonitrile (30:70, v/v) containing 10 mM ammonium formate as a mobile phase. When the method was applied to a commercial multivitamin tablet and a spiked one, the vitamins were successfully analyzed, and no influence of the matrix contained in the tablet was observed. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Use of ion-pairing reagent for improving iodine speciation analysis in seaweed by pressure-driven capillary electrophoresis and ultraviolet detection.

    PubMed

    Sun, Jiannan; Wang, Dan; Cheng, Heyong; Liu, Jinhua; Wang, Yuanchao; Xu, Zigang

    2015-01-30

    This study achieved resolution improvement for iodine speciation in the presence of an ion-pairing reagent by a pressure-driven capillary electrophoresis (CE) system. Addition of 0.01mM tetrabutyl ammonium hydroxide (TBAH) as the ion-pairing reagent into the electrophoretic buffer resulted in the complete separation of four iodine species (I(-), IO3(-), mono-iodothyrosine-MIT and di-iodothyrosine-DIT), because of the electrostatic interaction between TBAH and the negatively charged analytes. A +16kV separation voltage was applied along the separation capillary (50μm i.d., 80cm total and 60cm effective) with the inlet grounded. The detection wavelength was fixed at 210nm, and the pressure-driven flow rate was set at 0.12mLmin(-1) with an injected volume of 2μL. The optimal electrolyte consisted of 2mM borate, 2mM TBAH and 80% methanol with pH adjusted to 8.5. Baseline separation of iodine species was achieved within 7min. The detection limits for I(-), IO3(-), MIT and DIT were 0.052, 0.040, 0.032 and 0.025mgL(-1), respectively. The relative standard deviations of peak heights and areas were all below 3% for 5mgL(-1) and 5% for 1mgL(-1). Application of the proposed method was demonstrated by speciation analysis of iodine in two seaweed samples. The developed method offered satisfactory recoveries in the 91-99% range and good precisions (<5%). Good agreement between the determined values by the proposed CE method and the HPLC-ICP-MS method was also obtained. All results proved its great potential in routine analysis of iodine speciation in environmental, food and biological samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Determination of lipoic acid in human urine by capillary zone electrophoresis.

    PubMed

    Kubalczyk, Paweł; Głowacki, Rafał

    2017-07-01

    Fast, simple, and accurate CE method enabling determination of lipoic acid (LA) in human urine has been developed and validated. LA is a disulfide-containing natural compound absorbed from the organism's diet. Due to powerful antioxidant activity, LA has been used for prevention and treatment of various diseases and disorders, e.g. cardiovascular diseases, neurodegenerative disorders, and cancer. The proposed analytical procedure consists of liquid-liquid sample extraction, reduction of LA with tris(2-carboxyethyl)phosphine, derivatization with 1-benzyl-2-chloropyridinium bromide (BCPB) followed by field amplified sample injection stacking, capillary zone electrophoresis separation, and ultraviolet-absorbance detection of LA-BCPB derivative at 322 nm. Effective baseline electrophoretic separation was achieved within 6 min under the separation voltage of 20 kV (∼80 μA) using a standard fused-silica capillary (effective length 51.5 cm, 75 μm id) and BGE consisted of 0.05 mol/L borate buffer adjusted to pH 9. The experimentally determined limit of detection for LA in urine was 1.2 μmol/L. The calibration curve obtained for LA in urine showed linearity in the range 2.5-80 μmol/L, with R 2 0.9998. The relative standard deviation of the points of the calibration curve was lower than 10%. The analytical procedure was successfully applied to analysis of real urine samples from seven healthy volunteers who received single 100 mg dose of LA. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Capillary Electrophoresis Chips for Fingerprinting Endotoxin Chemotypes and Subclasses.

    PubMed

    Kocsis, Béla; Makszin, Lilla; Kilár, Anikó; Péterfi, Zoltán; Kilár, Ferenc

    2017-01-01

    Endotoxins (lipopolysaccharides, LPS; lipooligosaccharides, LOS) are components of the envelope of Gram-negative bacteria. These molecules, responsible for both advantageous and harmful biological activity of these microorganisms, are highly immunogenic and directly involved in numerous bacterial diseases in humans, such as Gram-negative sepsis. The characterization of endotoxins is of importance, since their physiological and pathophysiological effects depend on their chemical structure. The differences among the LPS from different bacterial serotypes and their mutants include variations mainly within the composition and length or missing of their O-polysaccharide chains. Microchip electrophoretic methodology enables the structural characterization of LPS molecules from several bacteria and the quantitative evaluation of components of endotoxin extracts. The improved microchip electrophoretic method is based on the direct labeling of endotoxins by covalent binding of a fluorescent dye. The classification of the S-type LPSs can be done according to their electrophoretic profiles, which are characteristics of the respective bacterial strains. According to the number, distribution, and the relative amounts of components in an endotoxin extract, it is possible to differentiate between the S-type endotoxins from different Gram-negative bacterial strains. The microchip electrophoresis affords high-resolution separation of pure and partially purified (e.g., obtained from whole-cell lysate) S and R endotoxins. This microchip technique provides a new, standardizable, fast, and sensitive method for the detection of endotoxins and for the quantitative evaluation of components of an endotoxin extract.

  9. Liquid-liquid extraction assisted by a carbon nanoparticles interface. Electrophoretic determination of atrazine in environmental samples.

    PubMed

    Caballero-Díaz, Encarnación; Simonet, Bartolomé; Valcárcel, Miguel

    2013-10-21

    A novel method for the determination of atrazine, using liquid-liquid extraction assisted by a nanoparticles film formed in situ and composed of organic solvent stabilized-carbon nanoparticles, is described. The presence of nanoparticles located at the liquid-liquid interface reinforced the extraction of analyte from matrix prior to capillary electrophoresis (CE) analysis. Some influential experimental variables were optimized in order to enhance the extraction efficiency. The developed procedure confirmed that carbon nanoparticles, especially multi-walled carbon nanotubes, are suitable to be used in sample treatment processes introducing new mechanisms of interaction with the analyte. The application of the proposed preconcentration method followed by CE detection enabled the determination of atrazine in spiked river water providing acceptable RSD values (11.6%) and good recoveries (about 87.0-92.0%). Additionally, a similar extraction scheme was tested in soil matrices with a view to further applications in real soil samples.

  10. Separation of multiphosphorylated peptide isomers by hydrophilic interaction chromatography on an aminopropyl phase.

    PubMed

    Singer, David; Kuhlmann, Julia; Muschket, Matthias; Hoffmann, Ralf

    2010-08-01

    The separation of isomeric phosphorylated peptides is challenging and often impossible for multiphosphorylated isomers using chromatographic and capillary electrophoretic methods. In this study we investigated the separation of a set of single-, double-, and triple-phosphorylated peptides (corresponding to the human tau protein) by ion-pair reversed-phase chromatography (IP-RPC) and hydrophilic interaction chromatography (HILIC). In HILIC both hydroxyl and aminopropyl stationary phases were tested with aqueous acetonitrile in order to assess their separation efficiency. The hydroxyl phase separated the phosphopeptides very well from the unphosphorylated analogue, while on the aminopropyl phase even isomeric phosphopeptides attained baseline separation. Thus, up to seven phosphorylated versions of a given tau domain were separated. Furthermore, the low concentration of an acidic ammonium formate buffer allowed an online analysis with electrospray ionization tandem mass spectrometry (ESI-MS/MS) to be conducted, enabling peptide sequencing and identification of phosphorylation sites.

  11. Capillary electrophoresis in two-dimensional separation systems: Techniques and applications.

    PubMed

    Kohl, Felix J; Sánchez-Hernández, Laura; Neusüß, Christian

    2015-01-01

    The analysis of complex samples requires powerful separation techniques. Here, 2D chromatographic separation techniques (e.g. LC-LC, GC-GC) are increasingly applied in many fields. Electrophoretic separation techniques show a different selectivity in comparison to LC and GC and very high separation efficiency. Thus, 2D separation systems containing at least one CE-based separation technique are an interesting alternative featuring potentially a high degree of orthogonality. However, the generally small volumes and strong electrical fields in CE require special coupling techniques. These technical developments are reviewed in this work, discussing benefits and drawbacks of offline and online systems. Emphasis is placed on the design of the systems, their coupling, and the detector used. Moreover, the employment of strategies to improve peak capacity, resolution, or sensitivity is highlighted. Various applications of 2D separations with CE are summarized. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Capillary moving-boundary isotachophoresis with electrospray ionization mass-spectrometric detection and hydrogen ion used as essential terminator: Methodology for sensitive analysis of hydroxyderivatives of s-triazine herbicides in waters.

    PubMed

    Malá, Zdena; Gebauer, Petr

    2017-10-06

    Capillary isotachophoresis (ITP) is an electrophoretic technique offering high sensitivity due to permanent stacking of the migrating analytes. Its combination with electrospray-ionization mass-spectrometric (ESI-MS) detection is limited by the narrow spectrum of ESI-compatible components but can be compensated by experienced system architecture. This work describes a methodology for sensitive analysis of hydroxyderivatives of s-triazine herbicides, based on implementation of the concepts of moving-boundary isotachophoresis and of H + as essential terminating component into cationic ITP with ESI-MS detection. Theoretical description of such kind of system is given and equations for zone-related boundary mobilities are derived, resulting in a much more general definition of the effective mobility of the terminating H + zone than used so far. Explicit equations allowing direct calculation for selected simple systems are derived. The presented theory allows prediction of stacking properties of particular systems and easy selection of suitable electrolyte setups. A simple ESI-compatible system composed of acetic acid and ammonium with H + and ammonium as a mixed terminator was selected for the analysis of 2-hydroxyatrazine and 2-hydroxyterbutylazine, degradation products of s-triazine herbicides. The proposed method was tested with direct injection without any sample pretreatment and provided excellent linearity and high sensitivity with limits of detection below 100ng/L (0.5nM). Example analyses of unspiked and spiked drinking and river water are shown. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Comparative Validation of the Determination of Sofosbuvir in Pharmaceuticals by Several Inexpensive Ecofriendly Chromatographic, Electrophoretic, and Spectrophotometric Methods.

    PubMed

    El-Yazbi, Amira F

    2017-01-20

    Sofosbuvir (SOFO) was approved by the U.S. Food and Drug Administration in 2013 for the treatment of hepatitis C virusinfection with enhanced antiviral potency compared with earlier analogs. Notwithstanding, all current editions of the pharmacopeias still do not present any analytical methods for the quantification of SOFO. Thus, rapid, simple, and ecofriendly methods for the routine analysis of commercial formulations of SOFO are desirable. In this study, five accurate methods for the determination of SOFO in pharmaceutical tablets were developed and validated. These methods include HPLC, capillary zone electrophoresis, HPTLC, and UV spectrophotometric and derivative spectrometry methods. The proposed methods proved to be rapid, simple, sensitive, selective, and accurate analytical procedures that were suitable for the reliable determination of SOFO in pharmaceutical tablets. An analysis of variance test with <em>P</em>-value &#x003E; 0.05 confirmed that there were no significant differences between the proposed assays. Thus, any of these methods can be used for the routine analysis of SOFO in commercial tablets.

  14. Integrated on-chip derivatization and electrophoresis for the rapid analysis of biogenic amines.

    PubMed

    Beard, Nigel P; Edel, Joshua B; deMello, Andrew J

    2004-07-01

    We demonstrate the monolithic integration of a chemical reactor with a capillary electrophoresis device for the rapid and sensitive analysis of biogenic amines. Fluorescein isothiocyanate (FITC) is widely employed for the analysis of amino-group containing analytes. However, the slow reaction kinetics hinders the use of this dye for on-chip labeling applications. Other alternatives are available such as o-phthaldehyde (OPA), however, the inferior photophysical properties and the UV lambdamax present difficulties when using common excitation sources leading to a disparity in sensitivity. Consequently, we present for the first time the use of dichlorotriazine fluorescein (DTAF) as a superior in situ derivatizing agent for biogenic amines in microfluidic devices. The developed microdevice employs both hydrodynamic and electroosmotic flow, facilitating the creation of a polymeric microchip to perform both precolumn derivatization and electrophoretic analysis. The favorable photophysical properties of the DTAF and its fast reaction kinetics provide detection limits down to 1 nM and total analysis times (including on-chip mixing and reaction) of <60 s. The detection limits are two orders of magnitude lower than current limits obtained with both FITC and OPA. The optimized microdevice is also employed to probe biogenic amines in real samples.

  15. Biologically driven neural platform invoking parallel electrophoretic separation and urinary metabolite screening.

    PubMed

    Page, Tessa; Nguyen, Huong Thi Huynh; Hilts, Lindsey; Ramos, Lorena; Hanrahan, Grady

    2012-06-01

    This work reveals a computational framework for parallel electrophoretic separation of complex biological macromolecules and model urinary metabolites. More specifically, the implementation of a particle swarm optimization (PSO) algorithm on a neural network platform for multiparameter optimization of multiplexed 24-capillary electrophoresis technology with UV detection is highlighted. Two experimental systems were examined: (1) separation of purified rabbit metallothioneins and (2) separation of model toluene urinary metabolites and selected organic acids. Results proved superior to the use of neural networks employing standard back propagation when examining training error, fitting response, and predictive abilities. Simulation runs were obtained as a result of metaheuristic examination of the global search space with experimental responses in good agreement with predicted values. Full separation of selected analytes was realized after employing optimal model conditions. This framework provides guidance for the application of metaheuristic computational tools to aid in future studies involving parallel chemical separation and screening. Adaptable pseudo-code is provided to enable users of varied software packages and modeling framework to implement the PSO algorithm for their desired use.

  16. High-Rate Assembly of Nanomaterials on Insulating Surfaces Using Electro-Fluidic Directed Assembly.

    PubMed

    Yilmaz, Cihan; Sirman, Asli; Halder, Aditi; Busnaina, Ahmed

    2017-08-22

    Conductive or semiconducting nanomaterials-based applications such as electronics and sensors often require direct placement of such nanomaterials on insulating surfaces. Most fluidic-based directed assembly techniques on insulating surfaces utilize capillary force and evaporation but are diffusion limited and slow. Electrophoretic-based assembly, on the other hand, is fast but can only be utilized for assembly on a conductive surface. Here, we present a directed assembly technique that enables rapid assembly of nanomaterials on insulating surfaces. The approach leverages and combines fluidic and electrophoretic assembly by applying the electric field through an insulating surface via a conductive film underneath. The approach (called electro-fluidic) yields an assembly process that is 2 orders of magnitude faster compared to fluidic assembly. By understanding the forces on the assembly process, we have demonstrated the controlled assembly of various types of nanomaterials that are conducting, semiconducting, and insulating including nanoparticles and single-walled carbon nanotubes on insulating rigid and flexible substrates. The presented approach shows great promise for making practical devices in miniaturized sensors and flexible electronics.

  17. Monitoring the enrichment of virgin olive oil with natural antioxidants by using a new capillary electrophoresis method.

    PubMed

    Nevado, Juan José Berzas; Robledo, Virginia Rodríguez; Callado, Carolina Sánchez-Carnerero

    2012-07-15

    The enrichment of virgin olive oil (VOO) with natural antioxidants contained in various herbs (rosemary, thyme and oregano) was studied. Three different enrichment procedures were used for the solid-liquid extraction of antioxidants present in the herbs to VOO. One involved simply bringing the herbs into contact with the VOO for 190 days; another keeping the herb-VOO mixture under stirring at room temperature (25°C) for 11 days; and the third stirring at temperatures above room level (35-40°C). The efficiency of each procedure was assessed by using a reproducible, efficient, reliable analytical capillary zone electrophoresis (CZE) method to separate and determine selected phenolic compounds (rosmarinic and caffeic acid) in the oil. Prior to electrophoretic separation, the studied antioxidants were isolated from the VOO matrix by using an optimised preconcentration procedure based on solid phase extraction (SPE). The CZE method was optimised and validated. Copyright © 2012 Elsevier Ltd. All rights reserved.

  18. Modern bioanalysis of proteins by electrophoretic techniques.

    PubMed

    Krizkova, Sona; Ryvolova, Marketa; Masarik, Michal; Zitka, Ondrej; Adam, Vojtech; Hubalek, Jaromir; Eckschlager, Tomas; Kizek, Rene

    2014-01-01

    In 1957, protein rich in cysteine able to bind cadmium was isolated from horse kidney and named as metallothionein according to its structural properties. Further, this protein and metallothionein-like proteins have been found in tissues of other animal species, yeasts, fungi and plants. MT is as a potential cancer marker in the focus of interest, and its properties, functions, and behavior under various conditions are intensively studied. Our protocol describes separation of two major mammalian isoforms of MT (MT-1 and MT-2) using capillary electrophoresis (CE) coupled with UV detector. This protocol enables separation of MT isoforms and studying of their basic behavior as well as their quantification with detection limit in units of ng per μL. Sodium borate buffer (20 mM, pH 9.5) was optimized as a background electrolyte, and the separation was carried out in fused silica capillary with internal diameter of 75 μm and electric field intensity of 350 V/cm. Optimal detection wavelength was 254 nm.

  19. Dopamine-imprinted monolithic column for capillary electrochromatography.

    PubMed

    Aşır, Süleyman; Sarı, Duygu; Derazshamshir, Ali; Yılmaz, Fatma; Şarkaya, Koray; Denizli, Adil

    2017-11-01

    A dopamine-imprinted monolithic column was prepared and used in capillary electrochromatography as stationary phase for the first time. Dopamine was selectively separated from aqueous solution containing the competitor molecule norepinephrine, which is similar in size and shape to the template molecule. Morphology of the dopamine-imprinted column was observed by scanning electron microscopy. The influence of the organic solvent content of mobile phase, applied pressure and pH of the mobile phase on the recognition of dopamine by the imprinted monolithic column has been evaluated, and the imprinting effect in the dopamine-imprinted monolithic polymer was verified. Developed dopamine-imprinted monolithic column resulted in excellent separation of dopamine from structurally related competitor molecule, norepinephrine. Separation was achieved in a short period of 10 min, with the electrophoretic mobility of 5.81 × 10 -5  m 2 V -1 s -1 at pH 5.0 and 500 mbar pressure. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. A sub-minute electrophoretic method for simultaneous determination of naphazoline and zinc.

    PubMed

    Ribeiro, Michelle M A C; Oliveira, Thiago C; Batista, Alex D; Muñoz, Rodrigo A A; Richter, Eduardo M

    2016-11-11

    This paper reports for the first time, a method for simultaneous determination of naphazoline (NPZ) and zinc (Zn) using an analytical separation technique (capillary electrophoresis with capacitively coupled contactless conductivity detection -CE-C 4 D). A single run is possible every 55s (sampling rate=65h -1 ). The separation by CE-C 4 D was achieved on a fused silica capillary (50cm length - 10cm effective, 50μm i.d.) with a background electrolyte (BGE) composed by 20mmolL -1 of 2-(morpholin-4-yl)ethane-1-sulfonic acid (MES) and 20mmolL -1 of histidine (HIS) (pH 6.0). Detection limits were estimated at 20 and 30μmolL -1 and recovery values for spiked samples were 98 and 102% for NPZ and Zn, respectively. The developed procedure was compared to HPLC (NPZ) and FAAS (Zn) and no statistically significant differences were observed (95% confidence level). Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Thermodynamics of acid-base dissociation of several cathinones and 1-phenylethylamine, studied by an accurate capillary electrophoresis method free from the Joule heating impact.

    PubMed

    Nowak, Paweł Mateusz; Woźniakiewicz, Michał; Mitoraj, Mariusz; Sagan, Filip; Kościelniak, Paweł

    2018-03-02

    Capillary electrophoresis is often used to the determination of the acid-base dissociation/deprotonation constant (pK a ), and the more advanced thermodynamic quantities describing this process (ΔH°, -TΔS°). Remarkably, it is commonly overlooked that due to insufficient dissipation of Joule heating the accuracy of parameters determined using a standard approach may be questionable. In this work we show an effective method allowing to enhance reliability of these parameters, and to estimate the magnitude of errors. It relies on finding a relationship between electrophoretic mobility and actual temperature, and performing pK a determination with the corrected mobility values. It has been employed to accurately examine the thermodynamics of acid-base dissociation of several amine compounds - known for their strong dependency of pK a on temperature: six cathinones (2-methylmethcathinone, 3-methylmethcathinone, 4-methylmethcathinone, α-pyrrolidinovalerophenone, methylenedioxypyrovalerone, and ephedrone); and structurally similar 1-phenylethylamine. The average pK a error caused by Joule heating noted at 25 °C was relatively small - 0.04-0.05 pH unit, however, a more significant inaccuracy was observed in the enthalpic and, in particular, entropic terms. An alternative correction method has also been proposed, simpler and faster, but not such effective in correcting ΔH°/-TΔS° terms. The corrected thermodynamic data have been interpreted with the aid of theoretical calculations, on a ground of the enthalpy-entropy relationships and the most probable structural effects accounting for them. Finally, we have demonstrated that the thermal dependencies of electrophoretic mobility, modelled during the correction procedure, may be directly used to find optimal temperature providing a maximal separation efficiency. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Influence of boundary on the effect of double-layer polarization and the electrophoretic behavior of soft biocolloids.

    PubMed

    Yeh, Li-Hsien; Fang, Kuo-Ying; Hsu, Jyh-Ping; Tseng, Shiojenn

    2011-12-01

    The electrophoresis of a soft particle comprising a rigid core and a charged porous membrane layer in a narrow space is modeled. This simulates, for example, the capillary electrophoresis of biocolloids such as cells and microorganisms, and biosensor types of device. We show that, in addition to the boundary effect, the effects of double-layer polarization (DLP) and the electroosmotic retardation flow can be significant, yielding interesting electrophoretic behaviors. For example, if the friction coefficient of the membrane layer and/or the boundary is large, then the DLP effect can be offset by the electroosmotic retardation flow, making the particle mobility to decrease with increasing double layer thickness, which is qualitatively consistent with many experimental observations in the literature, but has not been explained clearly in previous analyses. In addition, depending upon the thickness of double layer, the friction of the membrane layer of a particle can either retard or accelerate its movement, an interesting result which has not been reported previously. This work is the first attempt to show solid evidence for the influence of a boundary on the effect of DLP and the electrophoretic behavior of soft particles. The model proposed is verified by the experimental data in the literature. The results of numerical simulation provide valuable information for the design of bio-analytical apparatus such as nanopore-based sensing applications and for the interpretation of relevant experimental data. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Glycosaminoglycan blotting on nitrocellulose membranes treated with cetylpyridinium chloride after agarose-gel electrophoretic separation.

    PubMed

    Maccari, Francesca; Volpi, Nicola

    2002-09-01

    We describe a method for blotting and immobilizing several nonsulfated and sulfated complex polysaccharides on membranes made hydrophilic and positively charged by a cationic detergent after their separation by conventional agarose gel electrophoresis. Nitrocellulose membranes were derivatized with the cationic detergent cetylpyridinium chloride (CPC) and mixtures of glycosaminoglycans (GAGs) were capillary-blotted after their separation in agarose gel electrophoresis in barium acetate/1,2-diaminopropane. Single purified species of variously sulfated polysaccharides were transferred onto the derivatized membranes after electrophoresis with an efficiency of 100% and stained with alcian blue (irreversible staining) and toluidine blue (reversible staining) permitting about 0.1 nug threshold of detection. Nonsulfated polyanions, hyaluronic acid, a fructose-containing polysaccharide with a chondroitin backbone purified from Escherichia coli U1-41, and its defructosylated product, were also electrophoretically separated and transferred onto membranes. The limit of detection for desulfated GAGs was about 0.1-0.5 nug after irreversible or reversible staining. GAG extracts from bovine, lung and aorta, and human aorta and urine were separated by agarose gel electrophoresis and blotted on CPC-treated nitrocellulose membranes. The polysaccharide composition of these extracts was determined. The membrane stained with toluidine blue (reversible staining) was destained and the same lanes used for immunological detection or other applications. Reversible staining was also applied to recover single species of polysaccharides after electrophoretic separation of mixtures of GAGs and their transfer onto membranes. Single bands were released from the membrane with an efficiency of 70-100% for further biochemical characterization.

  4. Ultrafast preparation of a polyhedral oligomeric silsesquioxane-based ionic liquid hybrid monolith via photoinitiated polymerization, and its application to capillary electrochromatography of aromatic compounds.

    PubMed

    Zhang, Bingyu; Lei, Xiaoyun; Deng, Lijun; Li, Minsheng; Yao, Sicong; Wu, Xiaoping

    2018-06-06

    An ionic liquid hybrid monolithic capillary column was prepared within 7 min via photoinitiated free-radical polymerization of an ionic liquid monomer (1-butyl-3-vinylimidazolium-bis[(trifluoromethyl)sulfonyl]imide); VBIMNTF 2 ) and a methacryl substituted polyhedral oligomeric silsesquioxane (POSS-MA) acting as a cross-linker. The effects of composition of prepolymerization solution and initiation time on the porous structure and electroosmotic flow (EOF) of monolithic column were investigated. The hybrid monolith was characterized by scanning electron microscopy and FTIR. Owing to the introduction of a rigid nanosized POSS silica core and ionic liquids with multiple interaction sites, the monolithic column has a well-defined 3D skeleton morphology, good mechanical stability, and a stable anodic electroosmotic flow. The hybrid monolithic stationary phase was applied to the capillary electrochromatographic separation of various alkylbenzenes, phenols, anilines and polycyclic aromatic hydrocarbons (PAHs). The column efficiency is highest (98,000 plates/m) in case of alkylbenzenes. Mixed-mode retention mechanisms including hydrophobic interactions, π-π stacking, electrostatic interaction and electrophoretic mobility can be observed. This indicates the potential of this material in terms of efficient separation of analytes of different structural type. Graphical Abstract Preparation of a mixed-mode ionic liquid hybrid monolithic column via photoinitiated polymerization of methacryl substituted polyhedral oligomeric silsesquioxane (POSS-MA) and 1-butyl-3-vinylimidazolium-bis[(trifluoromethyl)sulfonyl]imide (VBIMNTF 2 ) ionic liquid for use in capillary electrochromatography.

  5. Capillary electrophoretic study of dibasic acids of different structures: Relation to separation of oxidative intermediates in remediation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Z.; Cocke, D.L.

    Dicarboxylic acids are important in environmental chemistry because they are intermediates in oxidative processes involved in natural remediation and waste management processes such as oxidative detoxification and advanced oxidation. Capillary electrophoresis (CE), a promising technique for separating and analyzing these intermediates, has been used to examine a series of dibasic acids of different structures and conformations. This series includes malonic acid, succinic acid, glutaric acid, adipic acid, pimelic acid, maleic acid, fumaric acid, phthalic acid, and trans, trans-muconic acid. The CE parameters as well as structural variations (molecular structure and molecular isomers, buffer composition, pH, applied voltage, injection mode, current,more » temperature, and detection wavelength) that affect the separations and analytical results have been examined in this study. Those factors that affect the separation have been delineated. Among these parameters, the pH has been found to be the most important, which affects the double-layer of the capillary wall, the electro-osmotic flow and analyte mobility. The optimum pH for separating these dibasic acids, as well as the other parameters are discussed in detail and related to the development of methods for analyzing oxidation intermediates in oxidative waste management procedures.« less

  6. Capillary electrophoresis separation of neutral organic compounds, pharmaceutical drugs, proteins and peptides, enantiomers, and anions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ding, Wei -Liang

    1999-02-12

    Addition of a novel anionic surfactant, namely lauryl polyoxyethylene sulfate, to an aqueous-acetonitrile electrolyte makes it possible to separate nonionic organic compounds by capillary electrophoresis. Separation is based on differences in the association between analytes and the surfactant. Highly hydrophobic compounds such as polyaromatic hydrocarbons are well separated by this new surfactant. Migration times of analytes can be readily changed over an unusually large range by varying the additive concentration and the proportion of acetonitrile in the electrolyte. Several examples are given, including the separation of four methylbenz[a]anthracene isomers and the separation of normal and deuterated acetophenone. The effect ofmore » adding this new surfactant to the acidic electrolyte was also investigated. Incorporation of cetyltrimethylammonium bromide in the electrolyte is shown to dynamically coat the capillary and reverse electroosmotic flow. Chiral recognition mechanism is studied using novel synthetic surfactants as chiral selectors, which are made from amino acids reacting with alkyl chloroformates. A satisfactory separation of both inorganic and organic anions is obtained using electrolyte solutions as high as 5 M sodium chloride using direct photometric detection. The effect of various salts on electrophoretic and electroosmotic mobility is further discussed. Several examples are given under high-salt conditions.« less

  7. MitoTracker Green labeling of mitochondrial proteins and their subsequent analysis by capillary electrophoresis with laser-induced fluorescence detection.

    PubMed

    Presley, Andrew D; Fuller, Kathryn M; Arriaga, Edgar A

    2003-08-05

    MitoTracker Green (MTG) is a mitochondrial-selective fluorescent label commonly used in confocal microscopy and flow cytometry. It is expected that this dye selectively accumulates in the mitochondrial matrix where it covalently binds to mitochondrial proteins by reacting with free thiol groups of cysteine residues. Here we demonstrate that MTG can be used as a protein labeling reagent that is compatible with a subsequent analysis by capillary electrophoresis with laser-induced fluorescence detection (CE-LIF). Although the MTG-labeled proteins and MTG do not seem to electrophoretically separate, an enhancement in fluorescence intensity of the product indicates that only proteins with free thiol groups are capable of reacting with MTG. In addition we propose that MTG is a partially selective label towards some mitochondrial proteins. This selectivity stems from the high MTG concentration in the mitochondrial matrix that favors alkylation of the available thiol groups in this subcellular compartment. To that effect we treated mitochondria-enriched fractions that had been prepared by differential centrifugation of an NS-1 cell lysate. This fraction was solubilized with an SDS-containing buffer and analyzed by CE-LIF. The presence of a band with fluorescence stronger than MTG alone also indicated the presence of an MTG-protein product. Confirming that MTG is labeling mitochondrial proteins was done by treating the solubilized mitochondrial fraction with 5-furoylquinoline-3-carboxaldehyde (FQ), a fluorogenic reagent that reacts with primary amino groups, and analysis by CE-LIF using two separate detection channels: 520 nm for MTG-labeled species and 635 nm for FQ-labeled species. In addition, these results indicate that MTG labels only a subset of proteins in the mitochondria-enriched fraction.

  8. Determination of the distribution constants of aromatic compounds and steroids in biphasic micellar phosphonium ionic liquid/aqueous buffer systems by capillary electrokinetic chromatography.

    PubMed

    Lokajová, Jana; Railila, Annika; King, Alistair W T; Wiedmer, Susanne K

    2013-09-20

    The distribution constants of some analytes, closely connected to the petrochemical industry, between an aqueous phase and a phosphonium ionic liquid phase, were determined by ionic liquid micellar electrokinetic chromatography (MEKC). The phosphonium ionic liquids studied were the water-soluble tributyl(tetradecyl)phosphonium with chloride or acetate as the counter ion. The retention factors were calculated and used for determination of the distribution constants. For calculating the retention factors the electrophoretic mobilities of the ionic liquids were required, thus, we adopted the iterative process, based on a homologous series of alkyl benzoates. Calculation of the distribution constants required information on the phase-ratio of the systems. For this the critical micelle concentrations (CMC) of the ionic liquids were needed. The CMCs were calculated using a method based on PeakMaster simulations, using the electrophoretic mobilities of system peaks. The resulting distribution constants for the neutral analytes between the ionic liquid and the aqueous (buffer) phase were compared with octanol-water partitioning coefficients. The results indicate that there are other factors affecting the distribution of analytes between phases, than just simple hydrophobic interactions. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. In-capillary derivatization with o-phthalaldehyde in the presence of 3-mercaptopropionic acid for the simultaneous determination of monosodium glutamate, benzoic acid, and sorbic acid in food samples via capillary electrophoresis with ultraviolet detection.

    PubMed

    Aung, Hnin-Pwint; Pyell, Ute

    2016-06-03

    For the rapid simultaneous determination of monosodium glutamate (MSG), benzoic acid (BA), and sorbic acid (SA) in canned food and other processed food samples, we developed a method that combines in-capillary derivatization with separation by capillary electrophoresis. This method employs the rapid derivatization of MSG with o-phthalaldehyde (OPA) in the presence of 3-mercaptopropionic acid (3-MPA) and enables the detection of the resulting OPA-MSG derivative and of non-derivatized BA and SA at 230nm. The composition of the background electrolyte and the parameters of derivatization and separation are as follows: 25mM borax containing 5mM OPA and 6mM 3-MPA, separation voltage 25mV, injection at 30mbar for 20s, and column temperature 25°C. Because of the high reaction rate and suitably adapted effective electrophoretic mobilities, band broadening due to the derivatization reaction at the start of the separation process is kept to a minimum. The optimized method is validated with respect to LOD, LOQ, linearity, recovery, and precision. This method can be applied to real samples such as soy, fish, oyster and sweet and sour chili sauces after application of appropriate clean-up steps. Mechanisms of zone broadening and zone focusing are discussed showing the validity of the employed theoretical approach regarding the dependence of the peak shape for OPA-MSG on the concentration of MSG in the sample. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Polyamidoamine dendrimers as sweeping agent and stationary phase for rapid and sensitive open-tubular capillary electrophoretic determination of heavy metal ions.

    PubMed

    Ge, Ying; Guo, Yujun; Qin, Weidong

    2014-04-01

    Polyamidoamine (PAMAM) dendrimer generation 2.5 was synthesized and evaluated as sweeping agent for in-column enrichment and as stationary phase for capillary electrochromatographic separation of heavy metal ions, viz., Pb(II), Cu(II), Hg(II), Zn(II) and Co(II), in a running buffer containing 4-(2-pyridylazo)resorcinol (PAR) as a chromogenic reagent. During experiment, a plug of aqueous PAMAM generation 2.5 solution was first introduced to the capillary, followed by electrokinetic injection of the heavy metal ions under a positive voltage. In this step, PAMAM acted as a sweeping agent, stacking the metal ions on the analyte/PAMAM boundary by forming metal ion-PAMAM complexes. The second preconcentration process occurred when PAR, a stronger ligand, moving toward the injection end under the electric field, reached and re-swept the metal ion-PAMAM zone, forming metal ion-PAR complexes. During separation, the neutral PAMAM moved toward the detector with the electroosmotic flow, dynamically coating the capillary wall, forming stationary phases that affected the separation of the metal ions. Due to the function of PAMAM, the detection sensitivity and resolution of the heavy metal ions improved significantly. Under the optimum conditions, the detection limits were 0.299, 0.184, 0.774, 0.182 and 0.047 μg/L for Pb(II), Cu(II), Hg(II), Zn(II) and Co(II), respectively. The method was successfully applied to the determination of heavy metals in snow, tap and rain water samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Separation of a chemically modified DNA oligomer bound by the carcinogen 2-Amino-1-methy-6-phenylimidazo [4,5-{beta}]pyridine using capillary gel electrophoresis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nguyen, T.N.

    1994-05-06

    We have optimized the reaction conditions under which unactivated metabolite of the food borne carcinogen 2-amino-1-methyl-6-phenylimidazo [4,5-{beta}]pyridine (PhIP) is covalently bound to the oligodeoxynucleotide d(CCTACGCATCC). Capillary electrophoresis (CE) was used to separate and characterize this DNA oligomer bound by PhIP. We observed 2 major and several minor PhIP adduct species. The 2 major adducts had different absorbance maxima; the major adduct eluates with faster and slower mobilities had absorbance maxima of 360 and 340 nm, respectively. One of the two major PhIP adduct species was resolvable but the peak was broad. Using detection at 260 nm, the other major PhIPmore » adduct with fastest electrophoretic mobility was not resolvable, but coelute with the huge broad unmodified DNA oligomer peak. However, at higher wavelengths (>320 nm) where DNA does not absorb, electropherograms generated by detection at these higher wavelengths showed very heterogeneous binding by PhIP to the DNA oligomer with no interfering absorbance by the DNA.« less

  12. Evaluation of capillary zone electrophoresis for the determination of protein composition in therapeutic immunoglobulins and human albumins.

    PubMed

    Christians, Stefan; van Treel, Nadine Denise; Bieniara, Gabriele; Eulig-Wien, Annika; Hanschmann, Kay-Martin; Giess, Siegfried

    2016-07-01

    Capillary zone electrophoresis (CZE) provides an alternative means of separating native proteins on the basis of their inherent electrophoretic mobilities. The major advantage of CZE is the quantification by UV detection, circumventing the drawbacks of staining and densitometry in the case of gel electrophoresis methods. The data of this validation study showed that CZE is a reliable assay for the determination of protein composition in therapeutic preparations of human albumin and human polyclonal immunoglobulins. Data obtained by CZE are in line with "historical" data obtained by the compendial method, provided that peak integration is performed without time correction. The focus here was to establish a rapid and reliable test to substitute the current gel based zone electrophoresis techniques for the control of protein composition of human immunoglobulins or albumins in the European Pharmacopoeia. We believe that the more advanced and modern CZE method described here is a very good alternative to the procedures currently described in the relevant monographs. Copyright © 2016 International Alliance for Biological Standardization. Published by Elsevier Ltd. All rights reserved.

  13. Zeta-potential Analyses using Micro Electrical Field Flow Fractionation with Fluorescent Nanoparticles

    PubMed Central

    Chang, Moon-Hwan; Dosev, Dosi; Kennedy, Ian M.

    2007-01-01

    Increasingly growing application of nanoparticles in biotechnology requires fast and accessible tools for their manipulation and for characterization of their colloidal properties. In this work we determine the zeta-potentials for polystyrene nanoparticles using micro electrical field flow fractionation (μ–EFFF) which is an efficient method for sorting of particles by size. The data obtained by μ–EFFF were compared to zeta potentials determined by standard capillary electrophoresis. For proof of concept, we used polystyrene nanoparticles of two different sizes, impregnated with two different fluorescent dyes. Fluorescent emission spectra were used to evaluate the particle separation in both systems. Using the theory of electrophoresis, we estimated the zeta-potentials as a function of size, dielectric permittivity, viscosity and electrophoretic mobility. The results obtained by the μ–EFFF technique were confirmed by the conventional capillary electrophoresis measurements. These results demonstrate the applicability of the μ–EFFF method not only for particle size separation but also as a simple and inexpensive tool for measurements of nanoparticles zeta potentials. PMID:18542710

  14. Improved stability and electrophoretic properties of preformed fluorescent cationic dye-DNA complexes in a taps-tetrapentylammonium buffer in agarose slab gels.

    PubMed

    Zeng, Z; Clark, S M; Mathies, R A; Glazer, A N

    1997-10-01

    High-resolution capillary electrophoresis sizing of preformed complexes of bis-intercalating fluorescent dyes with double-stranded DNA has been demonstrated using hydroxyethylcellulose and 3-[tris-(hydroxymethyl) methylamino]-1-propanesulfonic acid-tetrapentylammonium (Taps-NPe+4) buffers (S. M. Clark and R. A. Mathies, Anal. Chem. 69, 1355-1363, 1997). Such capillary electrophoresis separations were unattainable in conventional buffers containing other cations such as Tris+, Na+, and NH+4. We report here the behavior of preformed double-stranded DNA-dye complexes on agarose slab gel electrophoresis in 40 mM Taps-NPe+4, 1 mM H2EDTA, pH 8.2. Upon electrophoresis in this buffer (a) complexes formed at DNA base pairs:dye ratios ranging from 100:1 to 5:1 show the same mobility; (b) the half-lives of DNA-dye complexes with monointercalators are two- to threefold longer than those in commonly used Tris buffers; (c) there is little dye transfer between labeled and unlabeled DNA molecules; and (d) precise two-color sizing of preformed restriction fragment-dye complexes with fluorescent bisintercalators is achieved.

  15. Characterization of a single-isomer carboxymethyl-beta-cyclodextrin in chiral capillary electrophoresis.

    PubMed

    Fejős, Ida; Varga, Erzsébet; Benkovics, Gábor; Malanga, Milo; Sohajda, Tamás; Szemán, Julianna; Béni, Szabolcs

    2017-08-01

    In this work, the synthesis, characterization, and chiral capillary electrophoretic study of heptakis-(2,3-di-O-methyl-6-O-carboxymethyl)-β-CD (HDMCM), a single-isomer carboxymethylated CD, are presented. The pH-dependent and selector concentration-dependent enantiorecognition properties of HDMCM were investigated and discussed herein. The enantioseparation was assessed applying a structurally diverse set of noncharged, basic, and zwitterionic racemates. The increase in the selector concentration and gross negative charge of HDMCM improved the enantioseparation that could be observed in the majority of the cases. HDMCM was also successfully applied as BGE additive in NACE using a methanol-based system in order to prove the separation selectivity features and to highlight the broad applicability of HDMCM. Over 25 racemates showed partial or baseline separation with HDMCM under the conditions investigated, among which optimal enantiomer migration order was found for the four stereoisomers of tadalafil, tapentadol, and dapoxetine, offering the possibility of a chiral CE method development for chiral purity profiling of these drugs. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. DNA Sequencing by Capillary Electrophoresis

    PubMed Central

    Karger, Barry L.; Guttman, Andras

    2009-01-01

    Sequencing of human and other genomes has been at the center of interest in the biomedical field over the past several decades and is now leading toward an era of personalized medicine. During this time, DNA sequencing methods have evolved from the labor intensive slab gel electrophoresis, through automated multicapillary electrophoresis systems using fluorophore labeling with multispectral imaging, to the “next generation” technologies of cyclic array, hybridization based, nanopore and single molecule sequencing. Deciphering the genetic blueprint and follow-up confirmatory sequencing of Homo sapiens and other genomes was only possible by the advent of modern sequencing technologies that was a result of step by step advances with a contribution of academics, medical personnel and instrument companies. While next generation sequencing is moving ahead at break-neck speed, the multicapillary electrophoretic systems played an essential role in the sequencing of the Human Genome, the foundation of the field of genomics. In this prospective, we wish to overview the role of capillary electrophoresis in DNA sequencing based in part of several of our articles in this journal. PMID:19517496

  17. NACE-ESI-TOF MS to reveal phenolic compounds from olive oil: introducing enriched olive oil directly inside capillary.

    PubMed

    Gómez-Caravaca, Ana María; Carrasco-Pancorbo, Alegría; Segura-Carretero, Antonio; Fernández-Gutiérrez, Alberto

    2009-09-01

    Most CE methods for the analysis of phenols from olive oil use an aqueous electrolyte separation medium, although the importance of NACE is obvious, as this kind of CE seems to be more compatible with the hydrophobic olive oil matrix and could facilitate its direct injection. In the current work we develop a method involving SPE and NACE coupled to ESI-TOF MS. All the CE and ESI-TOF MS parameters were optimized in order to maximize the number of phenolic compounds detected and the sensitivity in their determination. Electrophoretic separation was carried out using a CE buffer system consisting of 25 mM NH(4)OAc/AcH in methanol/ACN (1/1 v/v) at an apparent pH value of 5.0. We studied in depth the effect of the nature and concentration of different electrolytes dissolved in different organic solvents and other experimental and instrumental CE variables. The results were compared with those obtained by CZE (with aqueous buffers) coupled to ESI-TOF MS; both methods offered to the analyst the chance to study phenolic compounds of different families (such as phenolic alcohols, lignans, complex phenols, flavonoids, etc.) from virgin olive oil by injecting methanolic extracts with efficient and fast CE separations. In the case of NACE method, we also studied the direct injection of the investigated matrix introducing a plug of olive oil directly into the capillary.

  18. Determination of Sulfonamide Residues in Food by Capillary Zone Electrophoresis with On-Line Chemiluminescence Detection Based on an Ag(III) Complex.

    PubMed

    Dai, Tingting; Duan, Jie; Li, Xinghua; Xu, Xiangdong; Shi, Hongmei; Kang, Weijun

    2017-06-16

    The presence of sulfonamide (SA) residues in foods is largely due to the raising of animals with sulfonamide antibiotics added or polluted feedstuff. In this paper, a sensitive method was developed for the determination of the residues of three sulfonamides in animal-derived food; the SAs include sulfadimidine (SDD), sulfadiazine (SDZ), and sulfathiazole (STZ). The method is based on capillary zone electrophoresis (CE) with online chemiluminescence (CL) detection, using an Ag(III) complex as an oxidant. These SAs have an inhibiting effect on the Ag(III)-luminol CL reaction. The electrophoretic buffer is 12.0 mM sodium borate. Under a set of optimized conditions, the linear ranges for the detections were found to be 10.0-200 µg·mL -1 for SDD and SDZ, and 2.0-50.0 µg·mL -1 for STZ. The detection limits were 2.75, 3.14, and 0.65 µg·mL -1 for SDD, SDZ, and STZ, respectively. Relative standard deviations (RSD) for the peak heights were between 2.1% and 2.8% (n = 7). The proposed method was used in the analysis of the SAs in samples from pork meat, chicken meat, and milk, showing satisfactory detection results. A reaction mechanism was also proposed for the Ag(III)-luminol-SA CL reactions. The method has potential applications for the monitoring of residue levels of the three SAs in food, providing food safety data.

  19. In vitro enantioselective human liver microsomal metabolism and prediction of in vivo pharmacokinetic parameters of tetrabenazine by DLLME-CE.

    PubMed

    Bocato, Mariana Zuccherato; de Lima Moreira, Fernanda; de Albuquerque, Nayara Cristina Perez; de Gaitani, Cristiane Masetto; de Oliveira, Anderson Rodrigo Moraes

    2016-09-05

    A new capillary electrophoresis method for the enantioselective analysis of cis- and trans- dihydrotetrabenazine (diHTBZ) after in vitro metabolism by human liver microsomes (HLMs) was developed. The chiral electrophoretic separations were performed by using tris-phosphate buffer (pH 2.5) containing 1% (w/v) carboxymethyl-β-CD as background electrolyte with an applied voltage of +15kV and capillary temperature kept at 15°C. Dispersive liquid-liquid microextraction was employed to extract the analytes from HLMs. Dichloromethane was used as extraction solvent (75μL) and acetone as disperser solvent (150μL). The method was validated according to official guidelines and showed to be linear over the concentration range of 0.29-19.57μmolL(-1) (r=0.9955) for each metabolite enantiomer. Within- and between-day precision and accuracy evaluated by relative standard deviation and relative error were lower than 15% for all enantiomers. The stability assay showed that the analytes kept stable under handling, storage and in metabolism conditions. After method validation, an enantioselective in vitro metabolism and in vivo pharmacokinetic prediction was carried out. This study showed a stereoselective metabolism and the observed kinetic profile indicated a substrate inhibition behavior. DiHTBZ enantiomers were catalyzed mainly by CYP2C19 and the predicted clearance suggests that liver metabolism is the main route for TBZ elimination which supports the literature data. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Screening HIV-1 fusion inhibitors based on capillary electrophoresis head-end microreactor targeting to the core structure of gp41.

    PubMed

    Liu, Lihong; Xu, Xiaoying; Liu, Yanhui; Zhang, Xuanxuan; Li, Lin; Jia, Zhimin

    2016-02-20

    In this paper, we design a microreactor based on electrophoretically mediated microanalysis (EMMA) with capillary electrophoresis (CE) for screening HIV-1 inhibitors that bind to the N-terminal heptad repeat (NHR, N36) region. Initially, a test sample plug is loaded into a capillary filled with buffer solution followed by N36 peptide solution, and the two solutions simultaneously mix by diffusion. Then, voltage is applied, and the sample molecules pass through the N36 peptide zone. The active compounds combine with N36, leading to a loss in the peak height of the active compound. More than 100 traditional Chinese medicine extracts (TCME) were screened, and an extract of Pheretima aspergillum (E. Perrier) (L5) was identified as having potent inhibitory activity. The results showed that L5 could significantly inhibit the HIV-1JR-FL pseudotyped virus infection; the 50% effective concentration (EC50) of L5 was approximately 32.1±1.2μg/mL, and the 50% cytotoxicity concentration (CC50) value of L5 was 146.9±4.4μg/mL, suggesting that L5 had low in vitro cytotoxicity on U87-CD4-CCR5 cells. The new method is simple and rapid, is free of antibodies, and does not require tedious processes. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Instant live-cell super-resolution imaging of cellular structures by nanoinjection of fluorescent probes.

    PubMed

    Hennig, Simon; van de Linde, Sebastian; Lummer, Martina; Simonis, Matthias; Huser, Thomas; Sauer, Markus

    2015-02-11

    Labeling internal structures within living cells with standard fluorescent probes is a challenging problem. Here, we introduce a novel intracellular staining method that enables us to carefully control the labeling process and provides instant access to the inner structures of living cells. Using a hollow glass capillary with a diameter of <100 nm, we deliver functionalized fluorescent probes directly into the cells by (di)electrophoretic forces. The label density can be adjusted and traced directly during the staining process by fluorescence microscopy. We demonstrate the potential of this technique by delivering and imaging a range of commercially available cell-permeable and nonpermeable fluorescent probes to cells.

  2. Enhanced capillary electrophoretic screening of Alzheimer based on direct apolipoprotein E genotyping and one-step multiplex PCR.

    PubMed

    Woo, Nain; Kim, Su-Kang; Sun, Yucheng; Kang, Seong Ho

    2018-01-01

    Human apolipoprotein E (ApoE) is associated with high cholesterol levels, coronary artery disease, and especially Alzheimer's disease. In this study, we developed an ApoE genotyping and one-step multiplex polymerase chain reaction (PCR) based-capillary electrophoresis (CE) method for the enhanced diagnosis of Alzheimer's. The primer mixture of ApoE genes enabled the performance of direct one-step multiplex PCR from whole blood without DNA purification. The combination of direct ApoE genotyping and one-step multiplex PCR minimized the risk of DNA loss or contamination due to the process of DNA purification. All amplified PCR products with different DNA lengths (112-, 253-, 308-, 444-, and 514-bp DNA) of the ApoE genes were analyzed within 2min by an extended voltage programming (VP)-based CE under the optimal conditions. The extended VP-based CE method was at least 120-180 times faster than conventional slab gel electrophoresis methods In particular, all amplified DNA fragments were detected in less than 10 PCR cycles using a laser-induced fluorescence detector. The detection limits of the ApoE genes were 6.4-62.0pM, which were approximately 100-100,000 times more sensitive than previous Alzheimer's diagnosis methods In addition, the combined one-step multiplex PCR and extended VP-based CE method was also successfully applied to the analysis of ApoE genotypes in Alzheimer's patients and normal samples and confirmed the distribution probability of allele frequencies. This combination of direct one-step multiplex PCR and an extended VP-based CE method should increase the diagnostic reliability of Alzheimer's with high sensitivity and short analysis time even with direct use of whole blood. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Determination of heterocyclic amines in flame-grilled fish patty by capillary electrophoresis.

    PubMed

    Wu, J; Wong, M K; Lee, H K; Lee, B L; Shi, C Y; Ong, C N

    1996-10-01

    A simple and reliable capillary zone electrophoretic (CZE) method for quantifying mutagenic and carcinogenic heterocyclic amines (HCAs) in cooked foods with UV-visible diode-array detection is described. The buffer system consisted of 50 mM disodium hydrogen phosphate, 30 mM sodium chloride, 20 mM citric acid and 26% methanol at pH 2.1. An uncoated silica tubing, 51 cm in length, was used for the CZE separation. The capillary tubing temperature was maintained at 25 degrees C with a constant voltage of 20 kV. The reproducibility of the method was over 95% for a five-replicate analysis of 10 micrograms/l-spiked 2-amino-3,4,7,8-tetramethylimidazo[4,5-f]quinoxaline (4,7,8-TriMeIQx) and the detection limit was in the low microgram/l range with coefficients of variation between 6 and 18%. An analytical run took only 15 min for 12 known HCAs. Using this procedure, up to 30 samples could be analysed in a single day. The method is reliable and can be used for screening of various HCAs. It has been applied to assess the concentrations of heterocyclic amines in otak-otak, a Malay-style grilled fish patty. The major mutagenic contaminant found in this foodstuff was 2-aminodipyrido[1,2-a:3',2'-d]imidazole (Glu-P-2) (286-1068 micrograms/kg), followed by 2-amino-1-methyl-6-phenylimidazo[4,5-b]pyridine (PhIP) (1.6-13.0 micrograms/kg) and 2-amino-3-methylimidazo[4,5-f]quinoline (IQ) (14.0-87.5 micrograms/kg). Two co-mutagens norharman (NH) and harman (H) were also detected in otak-otak at levels of 2.0-13.0 micrograms/kg and 12.8-21.3 micrograms/kg, respectively. The substantial amount of Glu-P-2 detected in otak-otak is probably a result of the ingredients used and the high temperature grilling process.

  4. Fast and sensitive method to determine parabens by capillary electrophoresis using automatic reverse electrode polarity stacking mode: application to hair samples.

    PubMed

    Sako, Alysson V F; Dolzan, Maressa D; Micke, Gustavo Amadeu

    2015-09-01

    This paper describes a fast and sensitive method for the determination of methyl, ethyl, propyl, and butylparaben in hair samples by capillary electrophoresis using automatic reverse electrode polarity stacking mode. In the proposed method, solutions are injected using the flush command of the analysis software (940 mbar) and the polarity switching is carried out automatically immediately after the sample injection. The advantages compared with conventional stacking methods are the increased analytical frequency, repeatability, and inter-day precision. All analyses were performed in a fused silica capillary (50 cm, 41.5 cm in effective length, 50 μm i.d.), and the background electrolyte was composed of 20 mmol L(-1) sodium tetraborate in 10 % of methanol, pH 9.3. For the reverse polarity, -25 kV/35 s was applied followed by application of +30 kV for the electrophoretic run. Temperature was set at 20 °C, and all analytes were monitored at 297 nm. The method showed acceptable linearity (r (2) > 0.997) in the studied range of 0.1-5.0 mg L(-1), limits of detection below 0.017 mg L(-1), and inter-day, intra-day, and instrumental precision better than 6.2, 3.6, and 4.6 %, respectively. Considering parabens is widely used as a preservative in many products and the reported possibility of damage to the hair and also to human health caused by these compounds, the proposed method was applied to evaluate the adsorption of parabens in hair samples. The results indicate that there is a greater adsorption of methylparaben compared to the other parabens tested and also dyed hairs had a greater adsorption capacity for parabens than natural hairs.

  5. Development of a temperature gradient focusing method for in situ extraterrestrial biomarker analysis.

    PubMed

    Danger, Grégoire; Ross, David

    2008-08-01

    Scanning temperature gradient focusing (TGF) is a recently described technique for the simultaneous concentration and separation of charged analytes. It allows for high analyte peak capacities and low LODs in microcolumn electrophoretic separations. In this paper, we present the application of scanning TGF for chiral separations of amino acids. Using a mixture of seven carboxyfluorescein succinimidyl ester-labeled amino acids (including five chiral amino acids) which constitute the Mars7 standard, we show that scanning TGF is a very simple and efficient method for chiral separations. The modulation of TGF separation parameters (temperature window, pressure scan rate, temperature range, and chiral selector concentration) allows optimization of peak efficiencies and analyte resolutions. The use of hydroxypropyl-beta-CD at low concentration (1-5 mmol/L) as a chiral selector, with an appropriate pressure scan rate ( -0.25 Pa/s) and with a low temperature range (3-25 degrees C over 1 cm) provided high resolution between enantiomers (Rs >1.5 for each pair of enantiomers) using a short, 4 cm long capillary. With these new results, the scanning TGF method appears to be a viable method for in situ trace biomarker analysis for future missions to Mars or other solar system bodies.

  6. Cell and Particle Interactions and Aggregation During Electrophoretic Motion

    NASA Technical Reports Server (NTRS)

    Davis, Robert H.

    2000-01-01

    The objectives of this research were (i) to perform experiments for observing and quantifying electrophoretic aggregation, (ii) to develop a theoretical description to appropriately analyze and compare with the experimental results, (iii) to study the combined effects of electrophoretic and gravitational aggregation of large particles, and the combined effects of electrophoretic and Brownian aggregation of small particles, and (iv) to perform a preliminary design of a potential future flight experiment involving electrophoretic aggregation. Electrophoresis refers to the motion of charged particles, droplets or molecules in response to an applied electric field. Electrophoresis is commonly used for analysis and separation of biological particles or molecules. When particles have different surface charge densities or potentials, they will migrate at different velocities in an electric field. This differential migration leads to the possibility that they will collide and aggregate, thereby preventing separation.

  7. Integrated hybrid polystyrene-polydimethylsiloxane device for monitoring cellular release with microchip electrophoresis and electrochemical detection

    PubMed Central

    Johnson, Alicia S.; Mehl, Benjamin T.; Martin, R. Scott

    2015-01-01

    In this work, a polystyrene (PS)-polydimethylsiloxane (PDMS) hybrid device was developed to enable the integration of cell culture with analysis by microchip electrophoresis and electrochemical detection. It is shown that this approach combines the fundamental advantages of PDMS devices (the ability to integrate pumps and valves) and PS devices (the ability to permanently embed fluidic tubing and electrodes). The embedded fused-silica capillary enables high temporal resolution measurements from off-chip cell culture dishes and the embedded electrodes provide close to real-time analysis of small molecule neurotransmitters. A novel surface treatment for improved (reversible) adhesion between PS and PDMS is described using a chlorotrimethylsilane stamping method. It is demonstrated that a Pd decoupler is efficient at handling the high current (and cathodic hydrogen production) resulting from use of high ionic strength buffers needed for cellular analysis; thus allowing an electrophoretic separation and in-channel detection. The separation of norepinephrine (NE) and dopamine (DA) in highly conductive biological buffers was optimized using a mixed surfactant system. This PS-PDMS hybrid device integrates multiple processes including continuous sampling from a cell culture dish, on-chip pump and valving technologies, microchip electrophoresis, and electrochemical detection to monitor neurotransmitter release from PC 12 cells. PMID:25663849

  8. Physicochemical characteristics of LR3-IGF1 protein inclusion bodies: electrophoretic mobility studies.

    PubMed

    Wangsa-Wirawan, N D; O'Neill, B K; Middelberg, A P

    2001-01-01

    A knowledge of the physicochemical properties of inclusion bodies is important for the rational design of potential recovery processes such as flotation and precipitation. In this study, measurement of the size and electrophoretic mobility of protein inclusion bodies and cell debris was undertaken. SDS-PAGE analysis of protein inclusion bodies subjected to different cleaning regimes suggested that electrophoretic mobility provides a qualitative measure of protein inclusion body purity. Electrophoretic mobility as a function of electrolyte type and ionic strength was investigated. The presence of divalent ions produced a stronger effect on electrophoretic mobility compared with monovalent ions. The isoelectric point of cell debris was significantly lower than that for the inclusion bodies. Hence, the contaminating cell debris may be separated from inclusion bodies using flotation by exploiting this difference in isoelectric points. Separation by this method is simple, convenient, and a possible alternative to the conventional route of centrifugation.

  9. Effect of passage number on electrophoretic mobility distributions of cultured human embryonic kidney cells

    NASA Technical Reports Server (NTRS)

    Kunze, M. E.

    1985-01-01

    A systematic investigation was undertaken to characterize population shifts that occur in cultured human embryonic kidney cells as a function of passage number in vitro after original explantation. This approach to cell population shift analysis follows the suggestion of Mehreshi, Klein and Revesz that perturbed cell populations can be characterized by electrophoretic mobility distributions if they contain subpopulations with different electrophoretic mobilities. It was shown that this is the case with early passage cultured human embryo cells.

  10. Anionic microemulsion to solvent stacking for on-line sample concentration of cationic analytes in capillary electrophoresis.

    PubMed

    Kukusamude, Chunyapuk; Srijaranai, Supalax; Quirino, Joselito P

    2014-05-01

    The common SDS microemulsion (i.e. 3.3% SDS, 0.8% octane, and 6.6% butanol) and organic solvents were investigated for the stacking of cationic drugs in capillary zone electrophoresis using a low pH separation electrolyte. The sample was prepared in the acidic microemulsion and a high percentage of organic solvent was included in the electrolyte at anodic end of capillary. The stacking mechanism was similar to micelle to solvent stacking where the micelles were replaced by the microemulsion for the transport of analytes to the organic solvent rich boundary. This boundary is found between the microemulsion and anodic electrolyte. The effective electrophoretic mobility of the cations reversed from the direction of the anode in the microemulsion to the cathode in the boundary. Microemulsion to solvent stacking was successfully achieved with 40% ACN in the anodic electrolyte and hydrodynamic sample injection of 21 s at 1000 mbar (equivalent to 30% of the effective length). The sensitivity enhancement factors in terms of peak height and corrected peak area were 15 to 35 and 21 to 47, respectively. The linearity R(2) in terms of corrected peak area were >0.999. Interday precisions (%RSD, n = 6) were 3.3-4.0% for corrected peak area and 2.0-3.0% for migration time. Application to spiked real sample is also presented. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Very fast electrophoretic determination of creatinine and uric acid in human urine using a combination of two capillaries with different internal diameters.

    PubMed

    Pavlíček, Václav; Tůma, Petr; Matějčková, Jana; Samcová, Eva

    2014-04-01

    A capillary system formed by combining 25 and 100 μm id capillaries was used in the short-end injection mode to determine creatinine and uric acid in human urine. The separation was performed at an electric field intensity of 2.3 kV/cm. Creatinine was determined in a BGE with a composition of 20 mM citric acid/NaOH (pH 3.0), and uric acid was determined in 20 mM MES/NaOH (pH 6.0). Under these conditions, migration times of 12.2 s for creatinine and 8.6 s for uric acid were achieved. The LOD value is 2.4 mg/L for creatinine and 0.9 mg/L for uric acid; the RSD for the migration time varies in the range 0.7-1.1% (intra day) to 1.0-7.5% (inter day); RSDs for the peak areas equalled 3.4-4.0% (intra day) and 4.3-4.7% (inter day). The determined creatinine values in seven urine samples vary in the range 221-1394 mg/L for creatinine and 87-615 mg/L for uric acid. t-Test did not reveal any statistically significant difference between the developed CE methodologies and reference methods - Jaffé reaction for creatinine and enzymatic uricase test for uric acid. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Evaluation of newly synthesized and commercially available charged cyclomaltooligosaccharides (cyclodextrins) for capillary electrokinetic chromatography.

    PubMed

    Culha, Mustafa; Schell, Fred M; Fox, Shannon; Green, Thomas; Betts, Thomas; Sepaniak, Michael J

    2004-01-22

    A highly new charged cyclodextrin (CD) derivatives, (6-O-carboxymethyl-2,3-di-O-methyl)cyclomaltoheptaoses (CDM-beta-CDs), was synthesized and characterized as anionic reagents for capillary electrophoresis (CE) in an electrokinetic chromatography mode of separation. Substitution with dimethyl groups at the secondary hydroxyl sites of the CD is aimed at influencing the magnitude and selectivity of analyte-CD interactions, while substitution by carboxymethyl groups at the primary hydroxyl sites provides for high charge and electrophoretic mobility. Full regioselective methylation at the secondary hydroxyl sites was achieved in this work, while substitution at the primary hydroxyl sites generated a mixture of multiply charged products. The separation performance of CDM-beta-CD was evaluated using a variety of analyte mixtures. The results obtained from commercially available negatively charged cyclodextrins, heptakis(2,3-di-O-methyl-6-O-sulfo)cyclomaltoheptaose (HDMS-beta-CD) and O-(carboxymethyl)cyclomaltoheptaose (CM-beta-CD) with an average degree of substitution one (DS 1), were compared to CDM-beta-CD using a sample composed of eight positional isomers of dihydroxynaphthalene. Four hydroxylated polychlorobiphenyl derivatives, a group of chiral and isomeric catchecins, and chiral binaphthyl compounds were also separated with CDM-beta-CD. The effect of adding neutral beta-cyclodextrin (beta-CD) into the running buffer containing charged cyclodextrins was investigated and provided evidence of significant inter-CD interactions. Under certain running buffer conditions, the charged cyclodextrins also appear to adsorb to the capillary walls to various degrees.

  13. Analysis of Toxic and Non-Toxic Alexandrium (Dinophyceae) Species Using Ribosomal RNA Gene Sequences

    DTIC Science & Technology

    1993-02-01

    Therriault, J.-C. (1988). Cladistic analysis of electrophoretic variants within the toxic dinoflagellate genus Protogonyaulax. Botanica Marina 31: 39- 51. 8... Botanica Marina 34: 575-587. Halegraeff, G. M., and Bolch, C.J. (1992). Transport of toxic dinoflagellate cysts via ship’s ballast water: implications...analysis of electrophoretic variants within the toxic dinoflagellate genus Protogonv-u.!a,. Botanica Marina 31: 39-51. Curran, J., Baillie, D.L

  14. Precise U and Pu isotope ratio measurements in nuclear samples by hyphenating capillary electrophoresis and MC-ICPMS.

    PubMed

    Martelat, Benoit; Isnard, Helene; Vio, Laurent; Dupuis, Erwan; Cornet, Terence; Nonell, Anthony; Chartier, Frederic

    2018-06-22

    Precise isotopic and elemental characterization of spent nuclear fuel is a major concern for the validation of the neutronic calculation codes and waste management strategy in the nuclear industry. Generally, the elements of interest, particularly U and Pu which are the two major elements present in spent fuel, are purified by ion exchange or extractant resins before off-line measurements by thermal ionization mass spectrometry. The aim of the present work was to develop a new analytical approach based on capillary electrophoresis (CE) hyphenated to a multicollector inductively coupled plasma mass spectrometer (MC-ICPMS) for online isotope ratio measurements. An electrophoretic separation protocol of U, Pu and the fraction containing fission products and minor actinides (Am and Cm) was developed using acetic acid as the electrolyte and complexing agent. The instrumentation for CE was designed to be used in a glove box and a laboratory-built interface was developed for hyphenation with MC-ICPMS. The separation was realized with only a few nL of a solution of spent nuclear fuel and the reproducibilities obtained on the U and Pu isotope ratios were on the order of a few ‰ which is comparable to those obtained by thermal ionization mass spectrometer (TIMS). This innovative protocol allowed a tremendous reduction of the analyte masses from μg to ng and also a drastic reduction of the liquid waste production from mL to μL. In addition, the time of analysis was shorted by at least a factor three. All of these improved parameters are of major interest for nuclear applications.

  15. Determination of Sulfonamide Residues in Food by Capillary Zone Electrophoresis with On-Line Chemiluminescence Detection Based on an Ag(III) Complex

    PubMed Central

    Dai, Tingting; Duan, Jie; Li, Xinghua; Xu, Xiangdong; Shi, Hongmei; Kang, Weijun

    2017-01-01

    The presence of sulfonamide (SA) residues in foods is largely due to the raising of animals with sulfonamide antibiotics added or polluted feedstuff. In this paper, a sensitive method was developed for the determination of the residues of three sulfonamides in animal-derived food; the SAs include sulfadimidine (SDD), sulfadiazine (SDZ), and sulfathiazole (STZ). The method is based on capillary zone electrophoresis (CE) with online chemiluminescence (CL) detection, using an Ag(III) complex as an oxidant. These SAs have an inhibiting effect on the Ag(III)–luminol CL reaction. The electrophoretic buffer is 12.0 mM sodium borate. Under a set of optimized conditions, the linear ranges for the detections were found to be 10.0–200 µg·mL−1 for SDD and SDZ, and 2.0–50.0 µg·mL−1 for STZ. The detection limits were 2.75, 3.14, and 0.65 µg·mL−1 for SDD, SDZ, and STZ, respectively. Relative standard deviations (RSD) for the peak heights were between 2.1% and 2.8% (n = 7). The proposed method was used in the analysis of the SAs in samples from pork meat, chicken meat, and milk, showing satisfactory detection results. A reaction mechanism was also proposed for the Ag(III)–luminol–SA CL reactions. The method has potential applications for the monitoring of residue levels of the three SAs in food, providing food safety data. PMID:28621728

  16. High pH instability of quaternary ammonium surfactant coatings in capillary electrophoresis.

    PubMed

    Shulman, Lisa; Pei, Lei; Bahnasy, Mahmoud F; Lucy, Charles A

    2017-06-12

    The two-tailed cationic surfactant dioctadecyldimethyl ammonium bromide (DODAB) produces semi-permanent coatings that yield strongly reversed electroosmotic flow (EOF), for example -0.31 ± 0.01 cm 2 kV -1 s -1 at pH 3.5. Moreover, these coatings are easy to prepare, regenerable, cost effective, and yield high efficiency (520 000-900 000 plates per m) separations of cationic proteins over many runs under acidic (pH 3.5) conditions. Given the quaternary amine functionality of DODAB, we were surprised to observe that DODAB coatings become unstable at pH > 7. At pH 7.2, the EOF of a DODAB coated capillary drifted from reversed to cathodic over only 5 runs, and protein separations became severely compromised. By pH 12, no EOF reversal was observed. Electrophoretic and mass spectrometric studies demonstrate that the coating decomposition involves a surface conversion of the quaternary amine in DODAB to a variety of products, although the exact mechanism remains elusive. Regardless, the results herein demonstrate that semi-permanent coatings based on cationic two-tailed surfactants such as DODAB are limited to separations using acidic buffers.

  17. Intracellular metabolism of a 2'-O-methyl-stabilized ribozyme after uptake by DOTAP transfection or asfree ribozyme. A study by capillary electrophoresis.

    PubMed Central

    Prasmickaite, L; Hogset, A; Maelandsmo, G; Berg, K; Goodchild, J; Perkins, T; Fodstad, O; Hovig, E

    1998-01-01

    The uptake and cellular metabolism of a fluorescein-labelled synthetic ribozyme stabilized by 2'- O -methyl modification and a 3' inverted thymidine have been studied, employing capillary gel electrophoresis as a novel and efficient analytical method. After internalization by DOTAP transfection, electrophoretic peaks of intact ribozyme and different degradation products were easily resolved and the amount of intracellular intact ribozyme was quantified to >10(7) molecules/cell at the peak value after 4 h transfection. On further incubation the amount of intracellular intact ribozyme decreased due to both degradation and efflux from the cell. However, even after 48 h incubation there were still >10(6) intact ribozyme molecules/cell. Clear differences both in uptake and in metabolism were seen when comparing DOTAP transfection with the uptake of free ribozyme. Fluorescence microscopy studies indicated that the ribozyme was mainly localized in intracellular granules, probably not accessible to target mRNA. This implies that agents able to release the intact ribozyme from intracellular vesicles into the cytosol should have a considerable potential for increasing the biological effects of synthetic ribozymes. PMID:9722645

  18. Capillary electrophoretic separation-based approach to determine the labeling kinetics of oligodeoxynucleotides

    PubMed Central

    Kanavarioti, Anastassia; Greenman, Kevin L.; Hamalainen, Mark; Jain, Aakriti; Johns, Adam M.; Melville, Chris R.; Kemmish, Kent; Andregg, William

    2014-01-01

    With the recent advances in electron microscopy (EM), computation, and nanofabrication, the original idea of reading DNA sequence directly from an image can now be tested. One approach is to develop heavy atom labels that can provide the contrast required for EM imaging. While evaluating tentative labels for the respective nucleobases in synthetic oligodeoxynucleotides (oligos), we developed a streamlined capillary electrophoresis (CE) protocol to assess the label stability, reactivity, and selectivity. We report our protocol using osmium tetroxide 2,2′-bipyridine (Osbipy) as a thymidine (T) specific label. The observed rates show that the labeling process is kinetically independent of both the oligo length, and the base composition. The conditions, i.e. temperature, optimal Osbipy concentration, and molar ratio of reagents, to promote 100% conversion of the starting oligo to labeled product were established. Hence the optimized conditions developed with the oligos could be leveraged to allow osmylation of effectively all Ts in single-stranded (ss) DNA, while achieving minimal mislabeling. In addition, the approach and methods employed here may be adapted to the evaluation of other prospective contrasting agents/labels to facilitate next-generation DNA sequencing by EM. PMID:23147698

  19. Determination of hydrolyzable tannins in the fruit of Terminalia chebula Retz. by high-performance liquid chromatography and capillary electrophoresis.

    PubMed

    Juang, Lih-Jeng; Sheu, Shuenn-Jyi; Lin, Ta-Chen

    2004-06-01

    A RP-HPLC method for determining fourteen components (gallic acid, chebulic acid, 1,6-di-O-galloyl-D-glucose, punicalagin, 3,4,6-tri-O-galloyl-D-glucose, casuarinin, chebulanin, corilagin, neochebulinic acid, terchebulin, ellagic acid, chebulagic acid, chebulinic acid, and 1,2,3,4,6-penta-O-galloyl-D-glucose) in the fruit of Terminalia chebula Retz. is described. The separation was achieved within 80 min using a binary gradient with mobile phases consisting of a pH 2.7 phosphoric acid solution and an 80% CH3CN solution. Capillary electrophoretic analyses were also attempted, and it was found that CZE (25 mM Na2B4O7, 5 mM NaH2PO4, pH 7.0) was an efficient method for the separation of gallotannins, while an MEKC method (25 mM Na2B4O7, 5 mM NaH2PO4, 20 mM SDS, pH 7.0, and 10% acetonitrile) provided a better separation for most of the tannins examined. The HPLC and CE methods developed were both successfully applied to the assay of tannins in commercial samples of Chebulae Fructus.

  20. Purity Determination by Capillary Electrophoresis Sodium Hexadecyl Sulfate (CE-SHS): A Novel Application For Therapeutic Protein Characterization.

    PubMed

    Beckman, Jeff; Song, Yuanli; Gu, Yan; Voronov, Sergey; Chennamsetty, Naresh; Krystek, Stanley; Mussa, Nesredin; Li, Zheng Jian

    2018-02-20

    Capillary gel electrophoresis using sodium dodecyl sulfate (CE-SDS) is used commercially to provide quantitative purity data for therapeutic protein characterization and release. In CE-SDS, proteins are denatured under reducing or nonreducing conditions in the presence of SDS and electrophoretically separated by molecular weight and hydrodynamic radius through a sieving polymer matrix. Acceptable performance of this method would yield protein peaks that are baseline resolved and symmetrical. Nominal CE-SDS conditions and parameters are not optimal for all therapeutic proteins, specifically for Recombinant Therapeutic Protein-1 (RTP-1), where acceptable resolution and peak symmetry were not achieved. The application of longer alkyl chain detergents in the running buffer matrix substantially improved assay performance. Matrix running buffer containing sodium hexadecyl sulfate (SHS) increased peak resolution and plate count 3- and 8-fold, respectively, compared to a traditional SDS-based running gel matrix. At Bristol-Myers Squibb (BMS), we developed and qualified a viable method for the characterization and release of RTP-1 using an SHS-containing running buffer matrix. This work underscores the potential of detergents other than SDS to enhance the resolution and separation power of CE-based separation methods.

  1. Application of partition technology to particle electrophoresis

    NASA Technical Reports Server (NTRS)

    Van Alstine, James M.; Harris, J. Milton; Karr, Laurel J.; Bamberger, Stephan; Matsos, Helen C.; Snyder, Robert S.

    1989-01-01

    The effects of polymer-ligand concentration on particle electrophoretic mobility and partition in aqueous polymer two-phase systems are investigated. Polymer coating chemistry and affinity ligand synthesis, purification, and analysis are conducted. It is observed that poly (ethylene glycol)-ligands are effective for controlling particle electrophoretic mobility.

  2. Quantitative Analysis of Color Differences within High Contrast, Low Power Reversible Electrophoretic Displays

    DOE PAGES

    Giera, Brian; Bukosky, Scott; Lee, Elaine; ...

    2018-01-23

    Here, quantitative color analysis is performed on videos of high contrast, low power reversible electrophoretic deposition (EPD)-based displays operated under different applied voltages. This analysis is coded in an open-source software, relies on a color differentiation metric, ΔE * 00, derived from digital video, and provides an intuitive relationship between the operating conditions of the devices and their performance. Time-dependent ΔE * 00 color analysis reveals color relaxation behavior, recoverability for different voltage sequences, and operating conditions that can lead to optimal performance.

  3. Quantitative Analysis of Color Differences within High Contrast, Low Power Reversible Electrophoretic Displays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Giera, Brian; Bukosky, Scott; Lee, Elaine

    Here, quantitative color analysis is performed on videos of high contrast, low power reversible electrophoretic deposition (EPD)-based displays operated under different applied voltages. This analysis is coded in an open-source software, relies on a color differentiation metric, ΔE * 00, derived from digital video, and provides an intuitive relationship between the operating conditions of the devices and their performance. Time-dependent ΔE * 00 color analysis reveals color relaxation behavior, recoverability for different voltage sequences, and operating conditions that can lead to optimal performance.

  4. Electrophoretic separation and analysis of living cells from solid tissues by several methods - Human embryonic kidney cell cultures as a model

    NASA Technical Reports Server (NTRS)

    Todd, Paul; Plank, Lindsay D.; Kunze, M. Elaine; Lewis, Marian L.; Morrison, Dennis R.

    1986-01-01

    The use of free-fluid electrophoresis methods to separate tissue cells having a specific function is discussed. It is shown that cells suspended by trypsinization from cultures of human embryonic kidney are electrophoretically heterogeneous and tolerate a wide range of electrophoresis buffers and conditions without significant attenuation of function. Moreover, these cells do not separate electrophoretically on the basis of size or cell position alone and can be separated according to their ability to give rise to progeny that produce specific plasminogen activators.

  5. Solvent-mediated nonelectrostatic ion-ion interactions predicting anomalies in electrophoresis.

    PubMed

    Goswami, Prakash; Dhar, Jayabrata; Ghosh, Uddipta; Chakraborty, Suman

    2017-03-01

    We study the effects of solvent-mediated nonelectrostatic ion-ion interactions on electrophoretic mobility of a charged spherical particle. To this end, we consider the case of low surface electrostatic potential resulting in the linearization of the governing equations, which enables us to deduce a closed-form analytical solution to the electrophoretic mobility. We subsequently compare our results to the standard model using Henry's approach and report the changes brought about by the nonelectrostatic potential. The classical approach to determine the electrophoretic mobility underpredicts the particle velocity when compared with experiments. We show that this issue can be resolved by taking into account nonelectrostatic interactions. Our analysis further reveals the phenomenon of electrophoretic mobility reversal that has been experimentally observed in numerous previous studies. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Three-dimensional fluorescence analysis of chernozem humic acids and their electrophoretic fractions

    NASA Astrophysics Data System (ADS)

    Trubetskoi, O. A.; Trubetskaya, O. E.

    2017-09-01

    Polyacrylamide gel electrophoresis in combination with size-exclusion chromatography (SEC-PAGE) has been used to obtain stable electrophoretic fractions of different molecular size (MS) from chernozem humic acids (HAs). Three-dimensional fluorescence charts of chernozem HAs and their fractions have been obtained for the first time, and all fluorescence excitation-emission maxima have been identified in the excitation wavelength range of 250-500 nm. It has been found that fractionation by the SEC-PAGE method results in a nonuniform distribution of protein- and humin-like fluorescence of the original HA preparation among the electrophoretic fractions. The electrophoretic fractions of the highest and medium MSs have only the main protein-like fluorescence maximum and traces of humin-like fluorescence. In the electrophoretic fraction of the lowest MS, the intensity of protein-like fluorescence is low, but the major part of humin-like fluorescence is localized there. Relationships between the intensity of protein-like fluorescence and the weight distribution of amino acids have been revealed, as well as between the degree of aromaticity and the intensity of humin-like fluorescence in electrophoretic fractions of different MSs. The obtained relationships can be useful in the interpretation of the spatial structural organization and ecological functions of soil HAs.

  7. One-step selective electrokinetic removal of inorganic anions from small volumes and its application as sample clean-up for mass spectrometric techniques.

    PubMed

    Tubaon, Ria Marni; Haddad, Paul R; Quirino, Joselito P

    2017-03-10

    The presence of inorganic anions in a sample interferes with mass spectrometric (MS) analysis. Here, a simple method to remove these ions from a liquid sample in one-step is described. The inorganic anions present in a 50μL sample were extracted into a low pH solution inside a 200μm i.d.×33cm long capillary by the use of an electric field. The selective removal of unwanted anions and retention of target analytes was accomplished by control of the apparent electrophoretic velocities of anions and analytes at a boundary that separated the sample and extraction solution. No physical barrier (e.g., membrane) was required and with the boundary situated at the tip of the capillary, efficient removal of inorganic anions (e.g., >80% removal) and good recovery of target analytes (e.g., >80% recovery) were achieved. The time required for removal of the inorganic anions was found to depend on their initial concentrations. The removal process was investigated using different concentrations of bromide and nitrate (as potassium salts) and negatively chargeable drugs as target analytes. This micro-sample clean-up technique used no organic solvents and little consumables and was studied to the determination of 0.6μg/L arsenic and 8.3μg/L vanadium in 500mg/L sodium chloride using inductively coupled plasma MS and 50μM angiotensin I in 1000mg/L sodium chloride using electrospray ionisation MS. Micro-sample clean-up was performed for 45min at 3kV in both demonstrations. The calculated recoveries for the metals at trace levels were 110-130%, and for the peptide was 103.8%. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Microscale Measurements of Michaelis-Menten Constants of Neuraminidase with Nanogel Capillary Electrophoresis for the Determination of the Sialic Acid Linkage.

    PubMed

    Gattu, Srikanth; Crihfield, Cassandra L; Holland, Lisa A

    2017-01-03

    Phospholipid nanogels enhance the stability and performance of the exoglycosidase enzyme neuraminidase and are used to create a fixed zone of enzyme within a capillary. With nanogels, there is no need to covalently immobilize the enzyme, as it is physically constrained. This enables rapid quantification of Michaelis-Menten constants (K M ) for different substrates and ultimately provides a means to quantify the linkage (i.e., 2-3 versus 2-6) of sialic acids. The fixed zone of enzyme is inexpensive and easily positioned in the capillary to support electrophoresis mediated microanalysis using neuraminidase to analyze sialic acid linkages. To circumvent the limitations of diffusion during static incubation, the incubation period is reproducibly achieved by varying the number of forward and reverse passes the substrate makes through the stationary fixed zone using in-capillary electrophoretic mixing. A K M value of 3.3 ± 0.8 mM (V max , 2100 ± 200 μM/min) was obtained for 3'-sialyllactose labeled with 2-aminobenzoic acid using neuraminidase from Clostridium perfringens that cleaves sialic acid monomers with an α2-3,6,8,9 linkage, which is similar to values reported in the literature that required benchtop analyses. The enzyme cleaves the 2-3 linkage faster than the 2-6, and a K M of 2 ± 1 mM (V max , 400 ± 100 μM/min) was obtained for the 6'-sialyllactose substrate. An alternative neuraminidase selective for 2-3 sialic acid linkages generated a K M value of 3 ± 2 mM (V max , 900 ± 300 μM/min) for 3'-sialyllactose. With a knowledge of V max , the method was applied to a mixture of 2-3 and 2-6 sialyllactose as well as 2-3 and 2-6 sialylated triantennary glycan. Nanogel electrophoresis is an inexpensive, rapid, and simple alternative to current technologies used to distinguish the composition of 3' and 6' sialic acid linkages.

  9. Microscale Measurements of Michaelis–Menten Constants of Neuraminidase with Nanogel Capillary Electrophoresis for the Determination of the Sialic Acid Linkage

    PubMed Central

    2016-01-01

    Phospholipid nanogels enhance the stability and performance of the exoglycosidase enzyme neuraminidase and are used to create a fixed zone of enzyme within a capillary. With nanogels, there is no need to covalently immobilize the enzyme, as it is physically constrained. This enables rapid quantification of Michaelis–Menten constants (KM) for different substrates and ultimately provides a means to quantify the linkage (i.e., 2-3 versus 2-6) of sialic acids. The fixed zone of enzyme is inexpensive and easily positioned in the capillary to support electrophoresis mediated microanalysis using neuraminidase to analyze sialic acid linkages. To circumvent the limitations of diffusion during static incubation, the incubation period is reproducibly achieved by varying the number of forward and reverse passes the substrate makes through the stationary fixed zone using in-capillary electrophoretic mixing. A KM value of 3.3 ± 0.8 mM (Vmax, 2100 ± 200 μM/min) was obtained for 3′-sialyllactose labeled with 2-aminobenzoic acid using neuraminidase from Clostridium perfringens that cleaves sialic acid monomers with an α2-3,6,8,9 linkage, which is similar to values reported in the literature that required benchtop analyses. The enzyme cleaves the 2-3 linkage faster than the 2-6, and a KM of 2 ± 1 mM (Vmax, 400 ± 100 μM/min) was obtained for the 6′-sialyllactose substrate. An alternative neuraminidase selective for 2-3 sialic acid linkages generated a KM value of 3 ± 2 mM (Vmax, 900 ± 300 μM/min) for 3′-sialyllactose. With a knowledge of Vmax, the method was applied to a mixture of 2-3 and 2-6 sialyllactose as well as 2-3 and 2-6 sialylated triantennary glycan. Nanogel electrophoresis is an inexpensive, rapid, and simple alternative to current technologies used to distinguish the composition of 3′ and 6′ sialic acid linkages. PMID:27936604

  10. A macrocyclic polyamine as an anion receptor in the capillary electrochromatographic separation of carbohydrates.

    PubMed

    Liu, Chuen-Ying; Chen, Tse-Hsien; Misra, Tarun Kumar

    2007-06-22

    An analytical approach of the 32-membered macrocyclic polyamine, 1,5,9,13,17,21,25,29-octaazacyclodotriacontane ([32]ane-N8) was described for the capillary electrochromatographic (CEC) separation of derivatized mono- and disaccharides. The column displayed reversal electroosmotic flow (EOF) at pH below 7.0, while a cathodic EOF was shown at pH above 7.0. The reductive amination of saccharides was carried out with p-aminobenzoic acid. Some parameters that affect the CEC separations were investigated. Several competitive ligands, such as Tris, EDTA and phosphate were also examined for the effect on the performance. We achieved a complete separation of all compounds as well as the excess derivatizing agent by using borate buffer (pH 9.0) in a mode of concentration gradient (60 mM inlet side and 70 mM outlet side). The relative standard deviation of the retention time measured for each sample was less than 4% in six continuous runs, suggesting that the bonded phase along with the gradient formed inside the column was quite stable. With the mixing modes of anion coordination, anion exchange, and shape discrimination, the interaction adequately accomplishes the separation of carbohydrates which are epimers or have different glycosidic linkage, although the electrophoretic migration is also involved in the separation mechanism.

  11. Determination of the dissociation constants (pKa) of secondary and tertiary amines in organic media by capillary electrophoresis and their role in the electrophoretic mobility order inversion.

    PubMed

    Cantu, Marcelo Delmar; Hillebranda, Sandro; Carrilho, Emanuel

    2005-03-11

    Non-aqueous capillary electrophoresis (NACE) may provide a selectivity enhancement in separations since the analyte dissociation constants (pKa) in organic media are different from those in aqueous solutions. In this work, we have studied the inversion in mobility order observed in the separation of tertiary (imipramine (IMI) and amitryptiline (AMI)) and secondary amines (desipramine (DES) and nortryptiline (NOR)) in water, methanol, and acetonitrile. We have determined the pKa values in those solvents and the variation of dissociation constants with the temperature. From these data, and applying the Van't Hoff equation, we have calculated the thermodynamic parameters deltaH and deltaS. The pKa values found in methanol for DES, NOR, IMI, and AMI were 10.80, 10.79, 10.38, and 10.33, respectively. On the other hand, in acetonitrile an opposite relation was found since the values were 20.60, 20.67, 20.74, and 20.81 for DES, NOR, IMI, and AMI. This is the reason why a migration order inversion is observed in NACE for these solvents. The thermodynamic parameters were evaluated and presented a tendency that can be correlated with that observed for pKa values.

  12. Enhancement of selectivity and resolution in the enantioseparation of uncharged compounds using mixtures of oppositely charged cyclodextrins in capillary electrophoresis.

    PubMed

    Abushoffa, Adel M; Fillet, Marianne; Servais, Anne-Catherine; Hubert, Philippe; Crommen, Jacques

    2003-01-01

    The enantiomeric separation of some nonsteroidal anti-inflammatory drugs (NSAIDs) was investigated in capillary electrophoresis (CE) using dual systems with mixtures of charged cyclodextrin (CD) derivatives. A significant enhancement of selectivity and resolution could be achieved in the enantioseparation of these analytes in their uncharged form by the simultaneous addition of two oppositely charged CD derivatives to the background electrolyte. The combination of the single-isomer cationic CD, permethyl-6-monoamino-6-monodeoxy-beta-CD (PMMAbetaCD) and the single-isomer polyanionic CD, heptakis-6-sulfato-beta-cyclodextrin (HSbetaCD) in a pH 2.5 phosphoric acid-triethanolamine buffer, was designed and employed for the enantioseparation of profens. The improvement in selectivity and resolution can be attributed to the fact that the two CDs, which lead to independent and enantioselective complexation with the analyte enantiomers, have not only opposite effects on the electrophoretic mobility of these compounds but also opposite affinity patterns towards the enantiomers of these compounds. Binding constants for these enantiomers with each CD were determined using linear regression approach, in order to be able to predict the effect of the concentrations of the two CDs on enantiomeric selectivity and resolution in such dual systems.

  13. High affinity γPNA sandwich hybridization assay for rapid detection of short nucleic acid targets with single mismatch discrimination.

    PubMed

    Goldman, Johnathan M; Zhang, Li Ang; Manna, Arunava; Armitage, Bruce A; Ly, Danith H; Schneider, James W

    2013-07-08

    Hybridization analysis of short DNA and RNA targets presents many challenges for detection. The commonly employed sandwich hybridization approach cannot be implemented for these short targets due to insufficient probe-target binding strengths for unmodified DNA probes. Here, we present a method capable of rapid and stable sandwich hybridization detection for 22 nucleotide DNA and RNA targets. Stable hybridization is achieved using an n-alkylated, polyethylene glycol γ-carbon modified peptide nucleic acid (γPNA) amphiphile. The γPNA's exceptionally high affinity enables stable hybridization of a second DNA-based probe to the remaining bases of the short target. Upon hybridization of both probes, an electrophoretic mobility shift is measured via interaction of the n-alkane modification on the γPNA with capillary electrophoresis running buffer containing nonionic surfactant micelles. We find that sandwich hybridization of both probes is stable under multiple binding configurations and demonstrate single base mismatch discrimination. The binding strength of both probes is also stabilized via coaxial stacking on adjacent hybridization to targets. We conclude with a discussion on the implementation of the proposed sandwich hybridization assay as a high-throughput microRNA detection method.

  14. Proteases in doping control analysis.

    PubMed

    Thevis, M; Maurer, J; Kohler, M; Geyer, H; Schänzer, W

    2007-07-01

    Urine manipulation in sports drug testing has become a serious problem for doping control laboratories, and recent scandals in elite endurance sports have revealed the problem of urine manipulation presumably using proteases, which will impede the detection of drugs such as erythropoietin (EPO) or other peptide hormones. Using commonly accepted analytical strategies, a protocol was developed enabling the determination of elevated protease activities in doping control specimens followed by the visualization of protein degradation and identification of proteases such as chymotrypsin, trypsin and papain. Therefore, protease detection kits based on fluorescein isothiocyanate-labeled casein were employed, and protease concentrations greater than 15 microg/mL of urine entailed subsequent 1-dimensional gel electrophoretic visualization of urinary proteins. The presence of 20 microg of proteases per mL of urine caused a complete degradation of proteins usually observed in urinary matrices ("trace of burning"), while respective proteases were still detected in spiked urine samples after 10 days of storage at + 4 and - 20 degrees C. Identification of target proteases at respective molecular weights was accomplished using bottom-up sequencing approaches based on in-gel digestion of separated enzymes followed by capillary liquid chromatography--Orbitrap tandem mass spectrometry.

  15. Numerical study of the influence of solid polarization on electrophoresis at finite Debye thickness.

    PubMed

    Bhattacharyya, Somnath; De, Simanta

    2015-09-01

    The influence of solid polarization on the electrophoresis of a uniformly charged dielectric particle for finite values of the particle-to-fluid dielectric permittivity ratio is analyzed quantitatively without imposing the thin Debye length or weak-field assumption. Present analysis is based on the computation of the coupled Poisson-Nernst-Planck and Stokes equations in the fluid domain along with the Laplace equation within the solid. The electrophoretic velocity is determined through the balance of forces acting on the particle. The solid polarization of the charged particle produces a reduction on its electrophoretic velocity compared to a nonpolarizable particle of the same surface charge density. In accordance with the existing thin-layer analysis, our computed results for thin Debye layer shows that the solid polarization is important only when the applied electric field is strong. When the Debye length is in the order of the particle size, the electrophoretic velocity decreases with the rise of the particle permittivity and attains a saturation limit at large values of the permittivity. Our computed solution for electrophoretic velocity is in agreement with the existing asymptotic analyses based on a thin Debye layer for limiting cases.

  16. Liquid-liquid and solid-phase extractions of phenols from virgin olive oil and their separation by chromatographic and electrophoretic methods.

    PubMed

    Bendini, Alessandra; Bonoli, Matteo; Cerretani, Lorenzo; Biguzzi, Barbara; Lercker, Giovanni; Toschi, Tullia Gallina

    2003-01-24

    The high oxidative stability of virgin olive oil is related to its high monounsaturated/polyunsaturated ratio and to the presence of antioxidant compounds, such as tocopherols and phenols. In this paper, the isolation of phenolic compounds from virgin olive oil, by different methods, was tested and discussed. Particularly liquid-liquid and solid-phase extraction methods were compared, assaying, for the latter, three stationary phases (C8, C18 and Diol) and several elution mixtures. Quantification of phenolic and o-diphenolic substances in the extracts was performed by the traditional Folin-Ciocalteau method and the sodium molybdate reaction, respectively. Furthermore, the quantification of phenolic compounds in the extracts and in a standard mixture was carried out both with diode array and mass spectrometric detection and capillary zone electrophoresis.

  17. Triazine herbicide imprinted monolithic column for capillary electrochromatography.

    PubMed

    Aşır, Süleyman; Derazshamshir, Ali; Yılmaz, Fatma; Denizli, Adil

    2015-12-01

    Trietazine was selectively separated from aqueous solution containing the competitor molecule cyanazine, which is similar in size and shape to the template molecule. Structural features of the molecularly imprinted column were figured out by SEM. The influence of the mobile-phase composition, applied electrical field, and pH of the mobile phase on the recognition of trietazine by the imprinted monolithic polymer has been evaluated, and the imprint effect in the trietazine-imprinted monolithic polymer was demonstrated by an imprinting factor. The optimized monolithic column resulted in separation of trietazine from a structurally related competitor molecule, cyanazine. In addition, fast separation was obtained within 6 min by applying higher electrical field, with the electrophoretic mobility of 2.97 × 10(-8) m(2) V(-1) s(-1) at pH 11.0. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Rapid analysis of colipase gene variants by multicapillary electrophoresis.

    PubMed

    Jaczó, Zsuzsanna; Pál, Eszter; Dénes, Réka; Somogyi, Anikó; Sasvári-Székely, Mária; Guttman, András; Rónai, Zsolt

    2015-06-01

    Despite of the fact that the Human Genome Project was completed more than a decade ago, identification of the genetic background of polygenic diseases is still challenging. Several somewhat different approaches are available to investigate inheritable factors of complex phenotypes, all require, however efficient, high-throughput techniques for SNP genotyping. In this paper, we report a robust and reliable multiplex PCR-RFLP for genotype and haplotype analysis of six SNPs (rs41270082, rs3748051, rs142027015, rs3748048, rs73404011, and rs72925892) of the colipase (CLPS) gene. A multicapillary (12 capillaries) electrophoresis unit was used for high throughput and sensitive analysis of the digestion fragments. A Microsoft Excel-based spreadsheet was designed for the flexible visualization and evaluation of the electrophoretic separations, which is readily adaptable for any kind of electrophoresis application. Haplotype analysis of the two loci localized in close proximity of each other was carried out by molecular method, extended haplotypes including all five SNPs in the 5' upstream region were calculated. The techniques were applied in a case-control association study of type 2 diabetes mellitus. Although, single marker analysis did not reveal any significant association, it was observed that the rare GGCCG haplotype of the five 5' upstream region SNPs was about three times more frequent among patients compared to healthy control population. Our results demonstrated the applicability of multicapillary CGE in large-scale, high-throughput SNP analysis, and suggested that the CLPS gene polymorphisms might be considered as genetic risk factor for type 2 diabetes mellitus. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. A method for determining electrophoretic and electroosmotic mobilities using AC and DC electric field particle displacements.

    PubMed

    Oddy, M H; Santiago, J G

    2004-01-01

    We have developed a method for measuring the electrophoretic mobility of submicrometer, fluorescently labeled particles and the electroosmotic mobility of a microchannel. We derive explicit expressions for the unknown electrophoretic and the electroosmotic mobilities as a function of particle displacements resulting from alternating current (AC) and direct current (DC) applied electric fields. Images of particle displacements are captured using an epifluorescent microscope and a CCD camera. A custom image-processing code was developed to determine image streak lengths associated with AC measurements, and a custom particle tracking velocimetry (PTV) code was devised to determine DC particle displacements. Statistical analysis was applied to relate mobility estimates to measured particle displacement distributions.

  20. Quality by design in the chiral separation strategy for the determination of enantiomeric impurities: development of a capillary electrophoresis method based on dual cyclodextrin systems for the analysis of levosulpiride.

    PubMed

    Orlandini, S; Pasquini, B; Del Bubba, M; Pinzauti, S; Furlanetto, S

    2015-02-06

    Quality by design (QbD) concepts, in accordance with International Conference on Harmonisation Pharmaceutical Development guideline Q8(R2), represent an innovative strategy for the development of analytical methods. In this paper QbD principles have been comprehensively applied in the set-up of a capillary electrophoresis method aimed to quantify enantiomeric impurities. The test compound was the chiral drug substance levosulpiride (S-SUL) and the developed method was intended to be used for routine analysis of the pharmaceutical product. The target of analytical QbD approach is to establish a design space (DS) of critical process parameters (CPPs) where the critical quality attributes (CQAs) of the method have been assured to fulfil the desired requirements with a selected probability. QbD can improve the understanding of the enantioseparation process, including both the electrophoretic behavior of enantiomers and their separation, therefore enabling its control. The CQAs were represented by enantioresolution and analysis time. The scouting phase made it possible to select a separation system made by sulfated-β-cyclodextrin and a neutral cyclodextrin, operating in reverse polarity mode. The type of neutral cyclodextrin was included among other CPPs, both instrumental and related to background electrolyte composition, which were evaluated in a screening phase by an asymmetric screening matrix. Response surface methodology was carried out by a Doehlert design and allowed the contour plots to be drawn, highlighting significant interactions between some of the CPPs. DS was defined by applying Monte-Carlo simulations, and corresponded to the following intervals: sulfated-β-cyclodextrin concentration, 9-12 mM; methyl-β-cyclodextrin concentration, 29-38 mM; Britton-Robinson buffer pH, 3.24-3.50; voltage, 12-14 kV. Robustness of the method was examined by a Plackett-Burman matrix and the obtained results, together with system repeatability data, led to define a method control strategy. The method was validated and was finally applied to determine the enantiomeric purity of S-SUL in pharmaceutical dosage forms. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Interpretive Reporting of Protein Electrophoresis Data by Microcomputer

    PubMed Central

    Talamo, Thomas S.; Losos, Frank J.; Kessler, G. Frederick

    1982-01-01

    A microcomputer based system for interpretive reporting of protein electrophoretic data has been developed. Data for serum, urine and cerebrospinal fluid protein electrophoreses as well as immunoelectrophoresis can be entered. Patient demographic information is entered through the keyboard followed by manual entry of total and fractionated protein levels obtained after densitometer scanning of the electrophoretic strip. The patterns are then coded, interpreted, and final reports generated. In most cases interpretation time is less than one second. Misinterpretation by computer is uncommon and can be corrected by edit functions within the system. These discrepancies between computer and pathologist interpretation are automatically stored in a data file for later review and possible program modification. Any or all previous tests on a patient may be reviewed with graphic display of the electrophoretic pattern. The system has been in use for several months and is presently well accepted by both laboratory and clinical staff. It also allows rapid storage, retrieval and analysis of protein electrophoretic datab.

  2. Electrophoretic separation techniques and their hyphenation to mass spectrometry in biological inorganic chemistry.

    PubMed

    Holtkamp, Hannah; Grabmann, Gerlinde; Hartinger, Christian G

    2016-04-01

    Electrophoretic methods have been widely applied in research on the roles of metal complexes in biological systems. In particular, CE, often hyphenated to a sensitive MS detector, has provided valuable information on the modes of action of metal-based pharmaceuticals, and more recently new methods have been added to the electrophoretic toolbox. The range of applications continues to expand as a result of enhanced CE-to-MS interfacing, with sensitivity often at picomolar level, and evolved separation modes allowing for innovative sample analysis. This article is a followup to previous reviews about CE methods in metallodrug research (Electrophoresis, 2003, 24, 2023-2037; Electrophoresis, 2007, 28, 3436-3446; Electrophoresis, 2012, 33, 622-634), also providing a comprehensive overview of metal species studied by electrophoretic methods hyphenated to MS. It highlights the latest CE developments, takes a sneak peek into gel electrophoresis, traces biomolecule labeling, and focuses on the importance of early-stage drug development. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Electrophoretic characterisation of the outer membrane proteins of Yersinia pestis isolated in north-east Brazil.

    PubMed Central

    Abath, F. G.; Almeida, A. M.; Ferreira, L. C.

    1989-01-01

    The outer membrane proteins of 38 Yersinia pestis isolates from all known plague foci of north-east Brazil were analysed by SDS-PAGE. Approximately 20 bands were consistently found in all strains analysed and 11 were selected for comparative studies. Although qualitative differences among the electrophoretic profiles of outer membrane proteins of wild Y. pestis isolates were not observed, quantitative alterations were clearly noted for most of these proteins. No particular quantitative alteration of the electrophoretic profile of outer membrane proteins could be associated with the period of isolation and geographic origin of the isolates. The 64 kDa outer membrane protein was significantly expressed in higher amounts among Y. pestis strains isolated from a recent plague outbreak. The possible use of electrophoretic profiles of outer membrane proteins of wild Y. pestis isolates as a tool for epidemiological studies and for the analysis of virulence determinants is discussed. Images Fig. 2 PMID:2606164

  4. A Semianalytical Analysis of Compressible Electrophoretic Cake Formation

    NASA Astrophysics Data System (ADS)

    Kambham, Kiran K. R.; Tuncay, Kagan; Corapcioglu, M. Yavuz

    1995-05-01

    Leaks in geomembrane liners of waste landfills and liquid impoundments cause chemical contaminants to leak into the subsurface environment. A mathematical model is presented to simulate electrophoretic sealing of impoundment leaks. The model describes the formation of a compressible clay cake because of electrical and gravitational forces. The model includes mass balance equations for the solid particles and liquid phase, modified Darcy's law in an electrical field, and Terzaghi's definition of effective stress. The formulation is presented in the Eulerian coordinates. The resulting second-order, nonlinear partial differential equation and the lower boundary condition are linearized to obtain an analytical solution for time-dependent settlement. After discretizing in time the analytical solution is applied to simulate compression of an accreting sediment. In the simulation of an accreting sediment, solid fluxes on either side of suspension/sediment interface are coupled using a no-jump condition. The velocity of a discrete particle in the suspension zone is assumed to be equal to the algebraic sum of electrophoretic and Stoke's settling velocities. An empirical relationship available in the literature is used to account for the effect of concentration on the velocity of solid particles in the suspension zone. The validity of the semianalytical approach is partially verified using an exact steady state solution for self-weight consolidation. The simulation results obtained for a set of material parameters are presented graphically. It is noted that the electrokinetic consolidation of sediment continues even after the completion of electrophoretic settling of all clay particles. An analysis reveals that the electrophoretic cake formation process is quite sensitive to voltage gradient and the coefficient of compressibility.

  5. Multicolor-based discrimination of 21 short tandem repeats and amelogenin using four fluorescent universal primers.

    PubMed

    Asari, Masaru; Okuda, Katsuhiro; Hoshina, Chisato; Omura, Tomohiro; Tasaki, Yoshikazu; Shiono, Hiroshi; Matsubara, Kazuo; Shimizu, Keiko

    2016-02-01

    The aim of this study was to develop a cost-effective genotyping method using high-quality DNA for human identification. A total of 21 short tandem repeats (STRs) and amelogenin were selected, and fluorescent fragments at 22 loci were simultaneously amplified in a single-tube reaction using locus-specific primers with 24-base universal tails and four fluorescent universal primers. Several nucleotide substitutions in universal tails and fluorescent universal primers enabled the detection of specific fluorescent fragments from the 22 loci. Multiplex polymerase chain reaction (PCR) produced intense FAM-, VIC-, NED-, and PET-labeled fragments ranging from 90 to 400 bp, and these fragments were discriminated using standard capillary electrophoretic analysis. The selected 22 loci were also analyzed using two commercial kits (the AmpFLSTR Identifiler Kit and the PowerPlex ESX 17 System), and results for two loci (D19S433 and D16S539) were discordant between these kits due to mutations at the primer binding sites. All genotypes from the 100 samples were determined using 2.5 ng of DNA by our method, and the expected alleles were completely recovered. Multiplex 22-locus genotyping using four fluorescent universal primers effectively reduces the costs to less than 20% of genotyping using commercial kits, and our method would be useful to detect silent alleles from commercial kit analysis. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Integrated circuit-based instrumentation for microchip capillary electrophoresis.

    PubMed

    Behnam, M; Kaigala, G V; Khorasani, M; Martel, S; Elliott, D G; Backhouse, C J

    2010-09-01

    Although electrophoresis with laser-induced fluorescence (LIF) detection has tremendous potential in lab on chip-based point-of-care disease diagnostics, the wider use of microchip electrophoresis has been limited by the size and cost of the instrumentation. To address this challenge, the authors designed an integrated circuit (IC, i.e. a microelectronic chip, with total silicon area of <0.25 cm2, less than 5 mmx5 mm, and power consumption of 28 mW), which, with a minimal additional infrastructure, can perform microchip electrophoresis with LIF detection. The present work enables extremely compact and inexpensive portable systems consisting of one or more complementary metal-oxide-semiconductor (CMOS) chips and several other low-cost components. There are, to the authors' knowledge, no other reports of a CMOS-based LIF capillary electrophoresis instrument (i.e. high voltage generation, switching, control and interface circuit combined with LIF detection). This instrument is powered and controlled using a universal serial bus (USB) interface to a laptop computer. The authors demonstrate this IC in various configurations and can readily analyse the DNA produced by a standard medical diagnostic protocol (end-labelled polymerase chain reaction (PCR) product) with a limit of detection of approximately 1 ng/microl (approximately 1 ng of total DNA). The authors believe that this approach may ultimately enable lab-on-a-chip-based electrophoretic instruments that cost on the order of several dollars.

  7. Surfactant-based ionic liquids for extraction of phenolic compounds combined with rapid quantification using capillary electrophoresis.

    PubMed

    Huang, Fangzhi; Berton, Paula; Lu, Chengfei; Siraj, Noureen; Wang, Chun; Magut, Paul K S; Warner, Isiah M

    2014-09-01

    A rapid liquid phase extraction employing a novel hydrophobic surfactant-based room temperature ionic liquid (RTIL), tetrabutylphosphonium dioctyl sulfosuccinate ([4C4 P][AOT]), coupled with capillary electrophoretic-UV (CE-UV) detection is developed for removal and determination of phenolic compounds. The long-carbon-chain RTIL used is sparingly soluble in most solvents and can be used to replace volatile organic solvents. This fact, in combination with functional-surfactant-anions, is proposed to reduce the interfacial energy of the two immiscible liquid phases, resulting in highly efficient extraction of analytes. Several parameters that influence the extraction efficiencies, such as extraction time, RTIL type, pH value, and ionic strength of aqueous solutions, were investigated. It was found that, under acidic conditions, most of the investigated phenols were extracted from aqueous solution into the RTIL phase within 12 min. Good linearity was observed over the concentration range of 0.1-80.0 μg/mL for all phenols investigated. The precision of this method, expressed as RSD, was determined to be within 3.4-5.3% range. The LODs (S/N = 3) of the method were in the range of 0.047-0.257 μg/mL. The proposed methodology was successfully applied to determination of phenols in real water samples. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Urea functionalized surface-bonded sol-gel coating for on-line hyphenation of capillary microextraction with high-performance liquid chromatography.

    PubMed

    Jillani, Shehzada Muhammad Sajid; Alhooshani, Khalid

    2018-03-30

    Sol-gel urea functionalized-[bis(hydroxyethyl)amine] terminated polydimethylsiloxane coating was developed for capillary microextraction-high performance liquid chromatographic analysis from aqueous samples. A fused silica capillary is coated from the inside with surface bonded coating material and is created through in-situ sol-gel reaction. The urea-functionalized coating was immobilized to the inner surface of the capillary by the condensation reaction of silanol groups of capillary and sol-solution. The characterization of the coating material was successfully done by using X-ray photoelectron spectroscopy, thermogravimetric analysis, field emission scanning electron microscope, and energy dispersive X-ray spectrometer. To make a setup of online capillary microextraction-high performance liquid chromatography, the urea functionalized capillary was installed in the HPLC manual injection port. The analytes of interest were pre-concentrated in the coated sampling loop, desorbed by the mobile phase, chromatographically separated on C-18 column, and analyzed by UV detector. Sol-gel coated capillaries were used for online extraction and high-performance liquid chromatographic analysis of phenols, ketones, aldehydes, and polyaromatic hydrocarbons. This newly developed coating showed excellent extraction for a variety of analytes ranging from highly polar to non-polar in nature. The analysis using sol-gel coating showed excellent overall sensitivity in terms of lower detection limits (S/N = 3) for the analytes (0.10 ng mL -1 -14.29 ng mL -1 ) with acceptable reproducibility that is less than 12.0%RSD (n = 3). Moreover, the capillary to capillary reproducibility of the analysis was also tested by changing the capillary of the same size. This provided excellent%RSD of less than 10.0% (n = 3). Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Fluorescence multiplexing with time-resolved and spectral discrimination using a near-IR detector.

    PubMed

    Zhu, Li; Stryjewski, Wieslaw; Lassiter, Suzanne; Soper, Steven A

    2003-05-15

    We report on the design and performance of a two-color, time-resolved detector for the acquisition of both steady-state and time-resolved fluorescence data acquired in real time during the capillary gel electrophoresis separation of DNA sequencing fragments. The detector consisted of a pair of pulsed laser diodes operating at 680 and 780 nm. The diode heads were coupled directly to single-mode fibers, which were terminated into a single fiber mounted via a FC/PC connector to the detector body. The detector contained a dichroic filter, which directed the dual-laser beams to an objective. The objective focused the laser light into a capillary gel column and also collected the resulting fluorescence emission. The dual-color emission was transmitted through the dichroic and focused onto a multimode fiber (core diameter 50 microm), which carried the luminescence to a pair of single-photon avalanche diodes (SPADs). The emission was sorted spectrally using a second dichroic onto one of two SPADs and isolated using appropriate interference filters (710- or 810-nm channel). The dual-color detector demonstrated a time response of 450 and 510 ps (fwhm) for the 710- and 810-nm channels, respectively. The mass detection limits for two near-IR dye-labeled sequencing primers electrophoresed in a capillary gel column were found to be 7.1 x 10(-21) and 3.2 x 10(-20) mol (SNR = 3) for the 710- and 810-nm detector channels, respectively. In addition, no leakage of luminescence excited at 680 nm was observed in the 810-nm channel or 780-nm excited luminescence into the 710-nm channel. An M13mp18 template was sequenced in a single capillary gel column using a two-color, two-lifetime format. The read length was found to be 650 base pairs for the test template at a calling accuracy of 95.1% using a linear poly(dimethylacrylamide) (POP6) gel column, with the read length determined primarily by the electrophoretic resolution produced by the sieving gel.

  10. Mass Spectrometric Quantification of N-Linked Glycans by Reference to Exogenous Standards.

    PubMed

    Mehta, Nickita; Porterfield, Mindy; Struwe, Weston B; Heiss, Christian; Azadi, Parastoo; Rudd, Pauline M; Tiemeyer, Michael; Aoki, Kazuhiro

    2016-09-02

    Environmental and metabolic processes shape the profile of glycoprotein glycans expressed by cells, whether in culture, developing tissues, or mature organisms. Quantitative characterization of glycomic changes associated with these conditions has been achieved historically by reductive coupling of oligosaccharides to various fluorophores following release from glycoprotein and subsequent HPLC or capillary electrophoretic separation. Such labeling-based approaches provide a robust means of quantifying glycan amount based on fluorescence yield. Mass spectrometry, on the other hand, has generally been limited to relative quantification in which the contribution of the signal intensity for an individual glycan is expressed as a percent of the signal intensity summed over the total profile. Relative quantification has been valuable for highlighting changes in glycan expression between samples; sensitivity is high, and structural information can be derived by fragmentation. We have investigated whether MS-based glycomics is amenable to absolute quantification by referencing signal intensities to well-characterized oligosaccharide standards. We report the qualification of a set of N-linked oligosaccharide standards by NMR, HPLC, and MS. We also demonstrate the dynamic range, sensitivity, and recovery from complex biological matrices for these standards in their permethylated form. Our results indicate that absolute quantification for MS-based glycomic analysis is reproducible and robust utilizing currently available glycan standards.

  11. Siderosomal ferritin. The missing link between ferritin and haemosiderin?

    PubMed Central

    Andrews, S C; Treffry, A; Harrison, P M

    1987-01-01

    A minor electrophoretically fast component was found in ferritin from iron-loaded rat liver in addition to a major electrophoretically slow ferritin similar to that observed in control rats. The electrophoretically fast ferritin showed immunological identity with the slow component, but on electrophoresis in SDS it gave a peptide of 17.3 kDa, in contrast with the electrophoretically slow ferritin, which gave a major band corresponding to the L-subunit (20.7 kDa). Thus the electrophoretically fast ferritin resembles that reported by Massover [(1985) Biochim. Biophys. Acta 829, 377-386] in livers of mice with short-term parenteral iron overload. The electrophoretically fast ferritin had a lower iron content (2000 Fe atoms/molecule) than the electrophoretically slow ferritin (3000 Fe atoms/molecule). Removal and re-incorporation of iron was possible without effect on the electrophoretic mobility of either ferritin species. On subcellular fractionation the electrophoretically fast ferritin was enriched in pellet fractions and was the sole soluble ferritin isolated from iron-laden secondary lysosomes (siderosomes). The amount and relative proportion of the electrophoretically fast species increased with iron loading. Haemosiderin isolated from siderosomes was found to contain a peptide reactive to anti-ferritin serum and corresponding to the 17.3 kDa peptide of the electrophoretically fast ferritin species. Unlike the electrophoretically slow ferritin, the electrophoretically fast ferritin did not become significantly radioactive in a 1 h biosynthetic labelling experiment. We conclude that the minor ferritin is not, as has been suggested for mouse liver ferritin, 'a completely new species of smaller holoferritin that represents a shift in the ferritin phenotype' in response to siderosis, but a precursor of haemosiderin, in agreement with the proposal by Richter [(1984) Lab. Invest. 50, 26-35] concerning siderosomal ferritin. Images Fig. 1. Fig. 2. Fig. 4. Fig. 5. PMID:3663170

  12. Automatic sampling and analysis of organics and biomolecules by capillary action-supported contactless atmospheric pressure ionization mass spectrometry.

    PubMed

    Hsieh, Cheng-Huan; Meher, Anil Kumar; Chen, Yu-Chie

    2013-01-01

    Contactless atmospheric pressure ionization (C-API) method has been recently developed for mass spectrometric analysis. A tapered capillary is used as both the sampling tube and spray emitter in C-API. No electric contact is required on the capillary tip during C-API mass spectrometric analysis. The simple design of the ionization method enables the automation of the C-API sampling system. In this study, we propose an automatic C-API sampling system consisting of a capillary (∼1 cm), an aluminium sample holder, and a movable XY stage for the mass spectrometric analysis of organics and biomolecules. The aluminium sample holder is controlled by the movable XY stage. The outlet of the C-API capillary is placed in front of the orifice of a mass spectrometer, whereas the sample well on the sample holder is moved underneath the capillary inlet. The sample droplet on the well can be readily infused into the C-API capillary through capillary action. When the sample solution reaches the capillary outlet, the sample spray is readily formed in the proximity of the mass spectrometer applied with a high electric field. The gas phase ions generated from the spray can be readily monitored by the mass spectrometer. We demonstrate that six samples can be analyzed in sequence within 3.5 min using this automatic C-API MS setup. Furthermore, the well containing the rinsing solvent is alternately arranged between the sample wells. Therefore, the C-API capillary could be readily flushed between runs. No carryover problems are observed during the analyses. The sample volume required for the C-API MS analysis is minimal, with less than 1 nL of the sample solution being sufficient for analysis. The feasibility of using this setup for quantitative analysis is also demonstrated.

  13. Paper Capillary Enables Effective Sampling for Microfluidic Paper Analytical Devices.

    PubMed

    Shangguan, Jin-Wen; Liu, Yu; Wang, Sha; Hou, Yun-Xuan; Xu, Bi-Yi; Xu, Jing-Juan; Chen, Hong-Yuan

    2018-06-06

    Paper capillary is introduced to enable effective sampling on microfluidic paper analytical devices. By coupling mac-roscale capillary force of paper capillary and microscale capillary forces of native paper, fluid transport can be flexibly tailored with proper design. Subsequently, a hybrid-fluid-mode paper capillary device was proposed, which enables fast and reliable sampling in an arrayed form, with less surface adsorption and bias for different components. The resulting device thus well supports high throughput, quantitative, and repeatable assays all by hands operation. With all these merits, multiplex analysis of ions, proteins, and microbe have all been realized on this platform, which has paved the way to level-up analysis on μPADs.

  14. Comparing nanostructured hydroxyapatite coating on AZ91 alloy samples via sol-gel and electrophoretic deposition for biomedical applications.

    PubMed

    Rojaee, Ramin; Fathi, Mohammadhossein; Raeissi, Keyvan

    2014-12-01

    Magnesium is one of the most critical elements in hard tissues regeneration and therefore causes speeding up the restoration of harmed bones, while high deterioration rate of magnesium in body fluid restricts it to be used as biodegradable implants. Alloying magnesium with some relatively nobler metals such as aluminium, zinc, rare earth elements, magnesium-bioceramics composites, and surface modification techniques are some of the routes to control magnesium corrosion rate. In this study AZ91 magnesium alloy had been coated by nanostructured hydroxyapatite via sol-gel dip coating and electrophoretical methods to survey the final barricade properties of the obtained coatings. In order to perform electrophoretic coating, powders were prepared by sol-gel method, and then the powders deposited on substrates utilizing direct current electricity. Zeta potentials of the electrophoresis suspensions were measured to determine a best mode for good quality coatings. Transmission Electron Microscopy (TEM), and Scanning Electron Microscopy (SEM) were used to confirm nanoscale dimension, and the uniformity of the nanostructured hydroxyapatite coating, respectively. Fourier Transform-Infrared and X-ray diffraction analysis were utilized for functional group and phase structure evaluation of the prepared coatings, correspondingly. Electrochemical corrosion tests were performed in SBF at 37±1 (°)C which revealed considerable increase in corrosion protection resistivity and corrosion current density for electrophoretic coated specimens versus sol-gel coated specimens. Results showed that both sol-gel and electrophoretical techniques seem to be suitable to coat magnesium alloys for biomedical applications but electrophoretic coating technique is a better choice due to the more homogeneity and more crystalline structure of the coating.

  15. Affinity capillary electrophoresis and density functional theory study of noncovalent interactions of cyclic peptide [Gly6 ]-antamanide with small cations.

    PubMed

    Pangavhane, Sachin; Böhm, Stanislav; Makrlík, Emanuel; Ruzza, Paolo; Kašička, Václav

    2017-08-01

    ACE and density functional theory were employed to study the noncovalent interactions of cyclic decapeptide glycine-6-antamanide ([Gly 6 ]AA), synthetic derivative of native antamanide (AA) peptide from the deadly poisonous fungus Amanita phalloides, with small cations (Li + , Rb + , Cs + , NH 4 + , and Ca 2+ ) in methanol. The strength of these interactions was quantified by the apparent stability constants of the appropriate complexes determined by ACE. The stability constants were calculated using the nonlinear regression analysis of the dependence of the effective electrophoretic mobility of [Gly 6 ]AA on the concentration of the above ions in the BGE (methanolic solution of 20 mM chloroacetic acid, 10 mM Tris, pH MeOH 7.8, containing 0-70 mM concentrations of the above ions added in the form of chlorides). Prior to stability constant calculation, the effective mobilities measured at actual temperature inside the capillary and at variable ionic strength of the BGEs were corrected to the values corresponding to the reference temperature of 25°C and to the constant ionic strength of 10 mM. From the above ions, Rb + and Cs + cations interacted weakly with [Gly 6 ]AA but no interactions of [Gly 6 ]AA with univalent Li + and NH 4 + ions and divalent Ca 2+ ion were observed. The apparent stability constants of [Gly 6 ]AA-Rb + and [Gly 6 ]AA-Cs + complexes were found to be equal to 13 ± 4 and 22 ± 3 L/mol, respectively. The structural characteristics of these complexes, such as position of the Rb + and Cs + ions in the cavity of the [Gly 6 ]AA molecule and the interatomic distances within these complexes, were obtained by the density functional theory calculations. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. APPLICATION OF CAPILLARY SUPERCRITICAL FLUID CHROMATOGRAPHY TO THE ANALYSIS OF A MIDDLE DISTILLATE FUEL

    EPA Science Inventory

    The paper describes the application of capillary supercritical fluid chromatography (SFC) to the analysis of a middle distillate fuel. Small diameter (50 micrometer i.d.) fused silica capillary columns coated with crosslinked 50% phenyl polymethylsiloxane provided high separation...

  17. A review of light-scattering techniques for the study of colloids in natural waters

    USGS Publications Warehouse

    Rees, T.F.

    1987-01-01

    In order to understand the movement of colloidal materials in natural waters, we first need to have a means of quantifying their physical characteristics. This paper reviews three techniques which utilize light-scattering phenomena to measure the translational diffusion coefficient, the rotational diffusion coefficient, and the electrophoretic mobility of colloids suspended in water. Primary emphasis is to provide sufficient theoretical detail so that hydrologists can evaluate the utility of photon correlation spectrometry, electrophoretic light scattering, and electric birefringence analysis. ?? 1987.

  18. Enhancing separation in short-capillary electrophoresis via pressure-driven backflow.

    PubMed

    Tian, Miaomiao; Wang, Yujia; Mohamed, Amara Camara; Guo, Liping; Yang, Li

    2015-07-01

    We present a novel easy-to-operate and efficient method to improve the separation efficiency in short-capillary electrophoresis by introducing steady backflow to counterbalance electro-osmotic flow without the use of any external pressure. The backflow was easily generated by tapering the capillary end, which was achieved by heating a straight capillary and stretching it with a constant force. We investigated the net fluidic transport rate under different tip lengths and separation voltages. Good run-to-run repeatability and capillary-to-capillary reproducibility of the present method were obtained with RSD less than 1.5%, indicating the stability of the fluid transport rate in the tapered capillary, which ensures the quantification and repeatability of capillary zone electrophoresis (CZE) analysis. Enhanced separation of the tapered short capillary electrophoresis was demonstrated by CZE analyzing amino acids and positional isomers. Baseline separations were achieved in less than 60 s using a tapered capillary with the effective length of 5 cm, while no separation was achieved using a normal capillary without a tapered tip. The present study provides a promising method to use pressure-driven backflow to enhance separation efficiency in short-capillary electrophoresis, which would be of potential value in a wide application for fast analysis of complex samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Further analyses of human kidney cell populations separated on the Space Shuttle

    NASA Technical Reports Server (NTRS)

    Stewart, Robin M.; Todd, Paul; Cole, Kenneth D.; Morrison, Dennis R.

    1992-01-01

    Cultured human embryonic kidney cells were separated into electrophoretic subpopulations in laboratory experiments and in two separation experiments on the STS-8 (Challenger) Space Shuttle flight using the mid-deck Continuous Flow Electrophoretic Separator (CFES). Populations of cells from each fraction were cultured for the lifetime of the cells, and supernatant medium was withdrawn and replaced at 4-day intervals. Withdrawn medium was frozen at -120 C for subsequent analysis. Enzyme assays, antibodies and gel electrophoresis were used as analytical tools for the detection and quantization of plasminogen activators in these samples. These assays of frozen-culture supernatant fluids confirmed the electrophoretic separation of plasminogen-activator-producing cells from nonproducing cells, the isolation of cells capable of sustained production, and the separation of cells that produce different plasminogen activators from one other.

  20. Cerebral capillary velocimetry based on temporal OCT speckle contrast.

    PubMed

    Choi, Woo June; Li, Yuandong; Qin, Wan; Wang, Ruikang K

    2016-12-01

    We propose a new optical coherence tomography (OCT) based method to measure red blood cell (RBC) velocities of single capillaries in the cortex of rodent brain. This OCT capillary velocimetry exploits quantitative laser speckle contrast analysis to estimate speckle decorrelation rate from the measured temporal OCT speckle signals, which is related to microcirculatory flow velocity. We hypothesize that OCT signal due to sub-surface capillary flow can be treated as the speckle signal in the single scattering regime and thus its time scale of speckle fluctuations can be subjected to single scattering laser speckle contrast analysis to derive characteristic decorrelation time. To validate this hypothesis, OCT measurements are conducted on a single capillary flow phantom operating at preset velocities, in which M-mode B-frames are acquired using a high-speed OCT system. Analysis is then performed on the time-varying OCT signals extracted at the capillary flow, exhibiting a typical inverse relationship between the estimated decorrelation time and absolute RBC velocity, which is then used to deduce the capillary velocities. We apply the method to in vivo measurements of mouse brain, demonstrating that the proposed approach provides additional useful information in the quantitative assessment of capillary hemodynamics, complementary to that of OCT angiography.

  1. Affinity Electrophoresis Using Ligands Attached To Polymers

    NASA Technical Reports Server (NTRS)

    Van Alstine, James M.; Snyder, Robert S.; Harris, J. M.; Brooks, D. E.

    1990-01-01

    In new technique, reduction of electrophoretic mobilities by addition of polyethylene glycol to ligands increases electrophoretic separabilities. In immuno-affinity electrophoresis, modification of ligands extends specificity of electrophoretic separation to particles having surface electric-charge structures otherwise making them electrophoretically inseparable. Modification of antibodies by polyethylene glycol greatly reduces ability to aggregate while enhancing ability to affect electrophoretic mobilities of cells. In hydrophobic-affinity electrophoresis, addition of polyethylene glycol reduces tendency toward aggregation of cells or macromolecules.

  2. An agarose gel electrophoretic method for analysis of hyaluronan molecular weight distribution.

    PubMed

    Lee, H G; Cowman, M K

    1994-06-01

    An electrophoretic method is described for determining the molecular weight distribution of hyaluronan (HA). The method involves separation of HA by electrophoresis on a 0.5% agarose gel, followed by detection of HA using the cationic dye Stains-All (3,3'-dimethyl-9-methyl-4,5,4'5'-dibenzothiacarbocyanine). The recommended sample load is 7 micrograms. Calibration of the method with HA standards of known molecular weight has established a linear relationship between electrophoretic mobility and the logarithm of the weight-average molecular weight over the range of approximately 0.2-6 x 10(6). The separated HA pattern may also be visualized after electrotransfer of HA from the agarose gel to a nylon membrane. The membrane may be stained with the dye alcian blue. Alternatively, specific detection of HA from impure samples can be achieved by probing the nylon membrane with biotin-labeled HA-binding protein and subsequent interaction with a streptavidin-linked gold reagent and silver staining for amplification. The electrophoretic method was used to analyze HA in two different liquid connective tissues. Normal human knee joint synovial fluid showed a narrow HA molecular weight distribution, with a peak at 6-7 x 10(6). Owl monkey vitreous HA also showed a narrow molecular weight distribution, with a peak at 5-6 x 10(6). These results agree well with available published data and indicate the applicability of the method to the analysis of impure HA samples which may be available in limited amounts.

  3. Density gradient electrophoresis of cultured human embryonic kidney cells

    NASA Technical Reports Server (NTRS)

    Plank, L. D.; Kunze, M. E.; Giranda, V.; Todd, P. W.

    1985-01-01

    Ground based confirmation of the electrophoretic heterogeneity of human embryonic kidney cell cultures, the general characterization of their electrophoretic migration, and observations on the general properties of cultures derived from electrophoretic subpopulations were studied. Cell migration in a density gradient electrophoresis column and cell electrophoretic mobility was determined. The mobility and heterogeneity of cultured human embryonic kidney cells with those of fixed rat erythrocytes as model test particle was compared. Electrophoretically separated cell subpopulations with respect to size, viability, and culture characteristics were examined.

  4. Sample injection and electrophoretic separation on a simple laminated paper based analytical device.

    PubMed

    Xu, Chunxiu; Zhong, Minghua; Cai, Longfei; Zheng, Qingyu; Zhang, Xiaojun

    2016-02-01

    We described a strategy to perform multistep operations on a simple laminated paper-based separation device by using electrokinetic flow to manipulate the fluids. A laminated crossed-channel paper-based separation device was fabricated by cutting a filter paper sheet followed by lamination. Multiple function units including sample loading, sample injection, and electrophoretic separation were integrated on a single paper based analytical device for the first time, by applying potential at different reservoirs for sample, sample waste, buffer, and buffer waste. As a proof-of-concept demonstration, mixed sample solution containing carmine and sunset yellow were loaded in the sampling channel, and then injected into separation channel followed by electrophoretic separation, by adjusting the potentials applied at the four terminals of sampling and separation channel. The effects of buffer pH, buffer concentration, channel width, and separation time on resolution of electrophoretic separation were studied. This strategy may be used to perform multistep operations such as reagent dilution, sample injection, mixing, reaction, and separation on a single microfluidic paper based analytical device, which is very attractive for building micro total analysis systems on microfluidic paper based analytical devices. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Integrating Internal Standards into Disposable Capillary Electrophoresis Devices To Improve Quantification

    PubMed Central

    2017-01-01

    To improve point-of-care quantification using microchip capillary electrophoresis (MCE), the chip-to-chip variabilities inherent in disposable, single-use devices must be addressed. This work proposes to integrate an internal standard (ISTD) into the microchip by adding it to the background electrolyte (BGE) instead of the sample—thus eliminating the need for additional sample manipulation, microchip redesigns, and/or system expansions required for traditional ISTD usage. Cs and Li ions were added as integrated ISTDs to the BGE, and their effects on the reproducibility of Na quantification were explored. Results were then compared to the conclusions of our previous publication which used Cs and Li as traditional ISTDs. The in-house fabricated microchips, electrophoretic protocols, and solution matrixes were kept constant, allowing the proposed method to be reliably compared to the traditional method. Using the integrated ISTDs, both Cs and Li improved the Na peak area reproducibility approximately 2-fold, to final RSD values of 2.2–4.7% (n = 900). In contrast (to previous work), Cs as a traditional ISTD resulted in final RSDs of 2.5–8.8%, while the traditional Li ISTD performed poorly with RSDs of 6.3–14.2%. These findings suggest integrated ISTDs are a viable method to improve the precision of disposable MCE devices—giving matched or superior results to the traditional method in this study while neither increasing system cost nor complexity. PMID:28192985

  6. Cobalt complexes as internal standards for capillary zone electrophoresis-mass spectrometry studies in biological inorganic chemistry.

    PubMed

    Holtkamp, Hannah U; Morrow, Stuart J; Kubanik, Mario; Hartinger, Christian G

    2017-07-01

    Run-by-run variations are very common in capillary electrophoretic (CE) separations and cause imprecision in both the migration times and the peak areas. This makes peak and kinetic trend identification difficult and error prone. With the aim to identify suitable standards for CE separations which are compatible with the common detectors UV, ESI-MS, and ICP-MS, the Co III complexes [Co(en) 3 ]Cl 3 , [Co(acac) 3 ] and K[Co(EDTA)] were evaluated as internal standards in the reaction of the anticancer drug cisplatin and guanosine 5'-monophosphate as an example of a classical biological inorganic chemistry experiment. These Co III chelate complexes were considered for their stability, accessibility, and the low detection limit for Co in ICP-MS. Furthermore, the Co III complexes are positively and negatively charged as well as neutral, allowing the detection in different areas of the electropherograms. The background electrolytes were chosen to cover a wide pH range. The compatibility to the separation conditions was dependent on the ligands attached to the Co III centers, with only the acetylacetonato (acac) complex being applicable in the pH range 2.8-9.0. Furthermore, because of being charge neutral, this compound could be used as an electroosmotic flow (EOF) marker. In general, employing Co complexes resulted in improved data sets, particularly with regard to the migration times and peak areas, which resulted, for example, in higher linear ranges for the quantification of cisplatin.

  7. Short-sweep capillary electrophoresis with a selective zinc fluorescence imaging reagent FluoZin-3 for determination of free and metalothionein-2a-bound Zn2+ ions.

    PubMed

    Nejdl, Lukas; Moravanska, Andrea; Smerkova, Kristyna; Mravec, Filip; Krizkova, Sona; Pomorski, Adam; Krężel, Artur; Macka, Mirek; Adam, Vojtech; Vaculovicova, Marketa

    2018-08-09

    A capillary electrophoretic (CE) method using a short-sweep approach and laser-induced fluorescence (LIF) detection (ShortSweepCE-LIF) was developed for determination of Zn 2+ and Cd 2+ as complexes with highly selective and sensitive fluorescent probe FluoZin-3. The ShortSweepCE-LIF method, established in this work, can be used for examining competitive Zn 2+ and Cd 2+ binding properties of metalloproteins or peptides. The parameters including background electrolyte composition, injection pressure and time as well as separation voltage were investigated. Under the optimized conditions, 80 mM HEPES, pH 7.4, with 1.5 μM FluoZin-3 was used as an electrolyte, hydrodynamic injection was performed at 50 mbar for 5 s, and separation voltage of 25 kV. Limits of detection for Zn 2+ and Cd 2+ were 4 and 125 nM, respectively. The developed method was demonstrated in a study of interactions between metalothionein-2a isoform and metal ions Zn 2+ , Co 2+ and Cd 2+ . It was found that FluoZin-3 was able to extract a single Zn 2+ ion, while added Co 2+ (in surplus) extracted only 2.4 Zn 2+ ions, and Cd 2+ extracted all 7 Zn 2+ ions present in the metalothionein molecule. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Polymer encapsulated inorganic black pigment nanoparticles and their electrophoretic characteristics.

    PubMed

    Sim, H H; Kim, Y J; Choi, H J

    2012-12-01

    Black inorganic pigment modified with poly(styrene-co-acrylonitrile) was fabricated via dispersion polymerization, and then the synthesized hybrid nanoparticles were examined by SEM to confirm their morphology, while their density and size were studied using a gas pycnometer and electrophoretic light scattering apparatus, respectively. We also confirmed their chemical structure and coated state via FT-IR and TGA. Electrophoretic characteristics including the zeta potential were examined via an electrophoretic light scattering apparatus, while the movement of particles was directly observed by an optical microscopy under an electric field applied. The hybrid nanoparticles were confirmed to possess an electrophoretic property as a potential candidate for the microcapsule-type electrophoretic display.

  9. Device to improve detection in electro-chromatography

    DOEpatents

    Garguilo, Michael G.; Paul, Phillip H.; Rakestraw, David J.

    2000-01-01

    Apparatus and method for improving the resolution of non-pressure driven capillary chromatographic systems, and particularly for capillary electrochromatography (CEC) systems. By reducing the cross-sectional area of a packed capillary column by means of a second open capillary contiguous with the outlet end of a packed capillary column, where the packed capillary column has a cross sectional area of between about 2 and 5 times that of the open capillary column, the phenomenon of band broadening in the transition region between the open capillary and the packed capillary column, where the individual components of the mixture are analyzed, can be eliminated, thereby providing for a significant improvement in resolution and more accurate detection and analysis.

  10. Device to improve detection in electro-chromatography

    DOEpatents

    Garguilo, Michael G.; Paul, Phillip H.; Rakestraw, David J.

    2002-01-01

    Apparatus and method for improving the resolution of non-pressure driven capillary chromatographic systems, and particularly for capillary electrochromatography (CEC) systems. By reducing the cross-sectional area of a packed capillary column by means of a second open capillary contiguous with the outlet end of a packed capillary column, where the packed capillary column has a cross sectional area of between about 2 and 5 times that of the open capillary column, the phenomenon of band broadening in the transition region between the open capillary and the packed capillary column, where the individual components of the mixture are analyzed, can be eliminated, thereby providing for a significant improvement in resolution and more accurate detection and analysis.

  11. The Diagnostic Value of Capillary Refill Time for Detecting Serious Illness in Children: A Systematic Review and Meta-Analysis

    PubMed Central

    Fleming, Susannah; Gill, Peter; Jones, Caroline; Taylor, James A.; Van den Bruel, Ann; Heneghan, Carl; Roberts, Nia; Thompson, Matthew

    2015-01-01

    Importance Capillary refill time (CRT) is widely recommended as part of the routine assessment of unwell children. Objective To determine the diagnostic value of capillary refill time for a range of serious outcomes in children. Methods We searched Medline, Embase and CINAHL from inception to June 2014. We included studies that measured both capillary refill time and a relevant clinical outcome such as mortality, dehydration, meningitis, or other serious illnesses in children aged up to 18 years of age. We screened 1,265 references, of which 24 papers were included in this review. Where sufficient studies were available, we conducted meta-analysis and constructed hierarchical summary ROC curves. Results Meta-analysis on the relationship between capillary refill time and mortality resulted in sensitivity of 34.6% (95% CI 23.9 to 47.1%), specificity 92.3% (88.6 to 94.8%), positive likelihood ratio 4.49 (3.06 to 6.57), and negative likelihood ratio 0.71 (0.60 to 0.84). Studies of children attending Emergency Departments with vomiting and diarrhea showed that capillary refill time had specificity of 89 to 94% for identifying 5% dehydration, but sensitivity ranged from 0 to 94%. This level of heterogeneity precluded formal meta-analysis of this outcome. Meta-analysis was not possible for other outcomes due to insufficient data, but we found consistently high specificity for a range of outcomes including meningitis, sepsis, admission to hospital, hypoxia, severity of illness and dengue. Conclusions Our results show that capillary refill time is a specific sign, indicating that it can be used as a “red-flag”: children with prolonged capillary refill time have a four-fold risk of dying compared to children with normal capillary refill time. The low sensitivity means that a normal capillary refill time should not reassure clinicians. PMID:26375953

  12. Salicylate-based anti-inflammatory drugs inhibit the early lesion of diabetic retinopathy.

    PubMed

    Zheng, Ling; Howell, Scott J; Hatala, Denise A; Huang, Kun; Kern, Timothy S

    2007-02-01

    It has been previously reported that aspirin inhibited the development of diabetic retinopathy in diabetic animals, raising the possibility that anti-inflammatory drugs may have beneficial effects on diabetic retinopathy. To further explore this, we compared effects of oral consumption of three different salicylate-based drugs (aspirin, sodium salicylate, and sulfasalazine) on the development of early stages of diabetic retinopathy in rats. These three drugs differ in their ability to inhibit cyclooxygenase but share an ability to inhibit nuclear factor-kappaB (NF-kappaB). Diabetes of 9-10 months duration significantly increased the number of TUNEL (transferase-mediated dUTP nick-end labeling)-positive capillary cells and acellular (degenerate) capillaries in the retinal vasculature, and all three salicylate-based drugs inhibited this cell death and formation of acellular capillaries without altering the severity of hyperglycemia. In short-term diabetes (2-4 months), all three salicylates inhibited the diabetes-induced loss of neuronal cells from the ganglion cell layer. Oral aspirin (as a representative of the salicylate family) inhibited diabetes-induced increase in NF-kappaB DNA-binding affinity in electrophoretic mobility shift assay and transcription factor array in nuclear extract isolated from whole retina. All three salicylates inhibited the diabetes-induced translocation of p50 (a subunit of NF-kappaB) into nuclei of retinal vascular endothelial cells of the isolated retinal vasculature, as well as of p50 and p65 into nuclei of cells in the ganglion cell layer and inner nuclear layer on whole-retinal sections. Sulfasalazine (also as a representative of the salicylates) inhibited the diabetes-induced upregulation of several inflammatory gene products, which are regulated by NF-kappaB, including vascular cell adhesion molecule, intracellular adhesion molecule-1, inducible nitric oxide synthase, and cyclooxygenase-2 in whole-retinal lysate. Salicylates, in doses administrated in our experiments, inhibited NF-kappaB and perhaps other transcription factors in the retina, were well tolerated, and offered new tools to investigate and inhibit the development of diabetic retinopathy.

  13. CSE-MECC two-dimensional capillary electrophoresis analysis of proteins in the mouse tumor cell (AtT-20) homogenate

    PubMed Central

    Chen, Xingguo; Fazal, Md. Abul; Dovichi, Norman J.

    2007-01-01

    Two-dimensional capillary electrophoresis was used for the separation of proteins and biogenic amines from the mouse AtT-20 cell line. The first-dimension capillary contained a TRIS-CHES-SDS-dextran buffer to perform capillary sieving electrophoresis, which is based on molecular weight of proteins. The second-dimension capillary contained a TRIS-CHES-SDS buffer for micel1ar electrokinetic capillary chromatography. After a 61 seconds preliminary separation, fractions from the first-dimension capillary were successively transferred to the second-dimension capillary, where they further separated by MECC. The two-dimensional separation required 60 minutes. PMID:17637850

  14. Multiplexed fluorescence detector system for capillary electrophoresis

    DOEpatents

    Yeung, E.S.; Taylor, J.A.

    1996-03-12

    A fluorescence detection system for capillary electrophoresis is provided wherein the detection system can simultaneously excite fluorescence and substantially simultaneously monitor separations in multiple capillaries. This multiplexing approach involves laser irradiation of a sample in a plurality of capillaries through optical fibers that are coupled individually with the capillaries. The array is imaged orthogonally through a microscope onto a charge-coupled device camera for signal analysis. 14 figs.

  15. Multiplexed fluorescence detector system for capillary electrophoresis

    DOEpatents

    Yeung, E.S.; Taylor, J.A.

    1994-06-28

    A fluorescence detection system for capillary electrophoresis is provided wherein the detection system can simultaneously excite fluorescence and substantially simultaneously monitor separations in multiple capillaries. This multiplexing approach involves laser irradiation of a sample in a plurality of capillaries through optical fibers that are coupled individually with the capillaries. The array is imaged orthogonally through a microscope onto a charge-coupled device camera for signal analysis. 14 figures.

  16. Multiplexed fluorescence detector system for capillary electrophoresis

    DOEpatents

    Yeung, Edward S.; Taylor, John A.

    1996-03-12

    A fluorescence detection system for capillary electrophoresis is provided wherein the detection system can simultaneously excite fluorescence and substantially simultaneously monitor separations in multiple capillaries. This multiplexing approach involves laser irradiation of a sample in a plurality of capillaries through optical fibers that are coupled individually with the capillaries. The array is imaged orthogonally through a microscope onto a charge-coupled device camera for signal analysis.

  17. Multiplexed fluorescence detector system for capillary electrophoresis

    DOEpatents

    Yeung, Edward S.; Taylor, John A.

    1994-06-28

    A fluorescence detection system for capillary electrophoresis is provided wherein the detection system can simultaneously excite fluorescence and substantially simultaneously monitor separations in multiple capillaries. This multiplexing approach involves laser irradiation of a sample in a plurality of capillaries through optical fibers that are coupled individually with the capillaries. The array is imaged orthogonally through a microscope onto a charge-coupled device camera for signal analysis.

  18. Fabrication of (K0.5Na0.5)(Nb0.7Ta0.3)O3 thick films by electrophoretic deposition

    NASA Astrophysics Data System (ADS)

    Vineetha, P.; Saravanan, K. Venkata

    2018-05-01

    (K0.5Na0.5)(Nb0.7Ta0.3)O3 (KNNT) thick films were prepared by electrophoretic deposition method on copper plates (substrates). Prior to the deposition, stable suspensions of KNNT powder were prepared in isopropyl alcohol medium with and without adding triethanolamine (TEA) as dispersant. The optical transmittance spectra with time for both the suspensions were recorded and compared. Suspensions with dispersant has shown low transmittance, which indicate that the particles were dispersed very well in isopropyl alcohol. Fourier Transform Infrared (FTIR) spectroscopy was used to analyze the adsorption of TEA on KNNT particles. Suspension with dispersant was used for electrophoretic deposition. The depositions were carried out at various d.c voltages, keeping the deposition duration and inter electrode distance constant. X-Ray diffraction was used for the phase analysis of the films.

  19. Discrimination between closed and open forms of lipases using electrophoretic techniques.

    PubMed

    Miled, N; Riviere, M; Cavalier, J F; Buono, G; Berti, L; Verger, R

    2005-03-15

    The enhanced catalytic activity of lipases is often associated with structural changes. The three-dimensional (3D) structures showed that the covalently inhibited lipases exist under their open conformations, in contrast to their native closed forms. We studied the inhibition of various lipases--human and dog gastric lipases, human pancreatic lipase, and Humicola lanuginosa lipase--by the octyl-undecyl phosphonate inhibitor, and we measured the subsequent modifications of their respective electrophoretic mobility. Furthermore, the experimental values of the isoelectric points found for the native (closed) and inhibited (open) lipases are in agreement with theoretical calculations based on the electrostatic potential. We concluded that there is a significant difference in the isoelectric points between the closed (native) and open (inhibited) conformations of the four lipases investigated. Thus, analysis of the electrophoretic pattern is proposed as an easy experimental tool to differentiate between a closed and an open form of a given lipase.

  20. In-gel staining of proteins in native polyacrylamide gel electrophoresis using meso-tetrakis(4-sulfonatophenyl) porphyrin.

    PubMed

    Divakar, K; Devi, G Nandhini; Gautam, Pennathur

    2012-01-01

    Protein identification in polyacrylamide gel electrophoresis (PAGE) requires post-electrophoretic steps like fixing, staining, and destaining of the gel, which are time-consuming and cumbersome. A new method for direct visualization of protein bands in PAGE has been developed using meso-tetrakis(4-sulfonatophenyl)porphyrin (TPPS) as a dye without the need for any post-electrophoretic steps; thus, separation and recovery of enzymes become much easier for further analysis. Activity staining was carried out to show that the biochemical activity of the enzymes was preserved after electrophoresis.

  1. Enzyme markers in inbred rat strains: genetics of new markers and strain profiles.

    PubMed

    Adams, M; Baverstock, P R; Watts, C H; Gutman, G A

    1984-08-01

    Twenty-six inbred strains of the laboratory rat (Rattus norvegicus) were examined for electrophoretic variation at an estimated 97 genetic loci. In addition to previously documented markers, variation was observed for the enzymes aconitase, aldehyde dehydrogenase, and alkaline phosphatase. The genetic basis of these markers (Acon-1, Ahd-2, and Akp-1) was confirmed. Linkage analysis between 35 pairwise comparisons revealed that the markers Fh-1 and Pep-3 are linked. The strain profiles of the 25 inbred strains at 11 electrophoretic markers are given.

  2. Effects of coating rectangular microscopic electrophoresis chamber with methylcellulose

    NASA Technical Reports Server (NTRS)

    Plank, L. D.

    1985-01-01

    One of the biggest problems in obtaining high accuracy in microscopic electrophoresis is the parabolic flow of liquid in the chamber due to electroosmotic backflow during application of the electric field. In chambers with glass walls the source of polarization leading to electroosmosis is the negative charge of the silicare and other ions that form the wall structure. It was found by Hjerten, who used a rotating 3.0 mm capillary tube for free zone electrophoresis, that precisely neutralizing this charge was extremely difficult, but if a neutral polymer matrix (formaldehyde fixed methylcellulose) was formed over the glass (quartz) wall the double layer was displaced and the viscosity at the shear plane increased so that electroosmotic flow could be eliminated. Experiments were designed to determine the reliability with which methylcellulose coating of the Zeiss Cytopherometer chamber reduced electroosmotic backflow and the effect of coating on the accuracy of cell electrophoretic mobility (EPN) determinations. Fixed rat erythrocytes (RBC) were used as test particles.

  3. Flow Analysis of Isobutane (R-600A) Inside AN Adiabatic Capillary Tube

    NASA Astrophysics Data System (ADS)

    Alok, Praveen; Sahu, Debjyoti

    2018-02-01

    Capillary tubes are simple narrow tubes but the phase change which occurs inside the capillary tubes is complex to analyze. In the present investigation, an attempt is made to analyze the flow of Isobutane (R-600a) inside the coiled capillary tubes for different load conditions by Homogeneous Equilibrium Model. The Length and diameter of the capillary tube not only depend on the pressure and temperature of the condenser and evaporator but also on the cooling load. The present paper investigates the change in dimensions of the coil capillary tube with respect to the change in cooling load on the system for the constant condenser and evaporator conditions. ANSYS CFX (Central Florida Expressway) software is used to study the flow characteristics of the refrigerant. Appropriate helical coil is selected for this analysis.

  4. Haematological and electrophoretic characterisation of β-thalassaemia in Yunnan province of Southwestern China

    PubMed Central

    Zhang, Jie; He, Jing; Mao, Xiaoqin; Zeng, Xiaohong; Chen, Hong; Su, Jie; Zhu, Baosheng

    2017-01-01

    Objectives β-Thalassaemia is widely found in Southwestern China. Characterisation of β-thalassaemia can improve screening and prenatal diagnosis for at-risk populations. Design A retrospective study. Methods In this study, the levels of haemoglobin alpha 2 (HbA2) and haemoglobin alpha (HbA) were analysed by gender for a total of 15 067 subjects screened by capillary electrophoresis. The cut-off value with the highest accuracy was established to identify β-thalassaemia in 723 patients suspected to have this disease. Haematological and electrophoretic characterisation of eight common types of β-thalassaemia were analysed in 486 β-thalassaemia subjects. Results HbA levels were significantly higher in men than in women, but there was no significant difference on HbA2 levels. A new cut-off value for the diagnosis of β-thalassaemia (HbA2≥4.0%) with the highest accuracy was proposed for the studied populations. Haemoglobin (Hb) was significantly higher in men compared with women (p<0.05), whereas no statistically significant differences were found for mean cell volume (MCV), mean cell haemoglobin (MCH), HbA and HbA2. The haemoglobin E (HbE) group showed comparatively higher values for haematological indices (Hb, MCV and MCH) than the other genotypes in heterozygous β-thalassaemia groups (p<0.05), and −28 (A>G) (HBB (β-globin):c.−78A>C) had significantly higher HbA2 values compared with other β-thalassaemia. Conclusions Ethnic groups have diversified β-globin gene mutations and considerable haematological variations. Our study will lay the foundation for screening programmes and clinical management of thalassaemia in Southwestern China. PMID:28143837

  5. Haematological and electrophoretic characterisation of β-thalassaemia in Yunnan province of Southwestern China.

    PubMed

    Zhang, Jie; He, Jing; Mao, Xiaoqin; Zeng, Xiaohong; Chen, Hong; Su, Jie; Zhu, Baosheng

    2017-01-31

    β-Thalassaemia is widely found in Southwestern China. Characterisation of β-thalassaemia can improve screening and prenatal diagnosis for at-risk populations. A retrospective study. In this study, the levels of haemoglobin alpha 2 (HbA 2 ) and haemoglobin alpha (HbA) were analysed by gender for a total of 15 067 subjects screened by capillary electrophoresis. The cut-off value with the highest accuracy was established to identify β-thalassaemia in 723 patients suspected to have this disease. Haematological and electrophoretic characterisation of eight common types of β-thalassaemia were analysed in 486 β-thalassaemia subjects. HbA levels were significantly higher in men than in women, but there was no significant difference on HbA 2 levels. A new cut-off value for the diagnosis of β-thalassaemia (HbA 2 ≥4.0%) with the highest accuracy was proposed for the studied populations. Haemoglobin (Hb) was significantly higher in men compared with women (p<0.05), whereas no statistically significant differences were found for mean cell volume (MCV), mean cell haemoglobin (MCH), HbA and HbA 2 . The haemoglobin E (HbE) group showed comparatively higher values for haematological indices (Hb, MCV and MCH) than the other genotypes in heterozygous β-thalassaemia groups (p<0.05), and -28 (A>G) (HBB (β-globin):c.-78A>C) had significantly higher HbA 2 values compared with other β-thalassaemia. Ethnic groups have diversified β-globin gene mutations and considerable haematological variations. Our study will lay the foundation for screening programmes and clinical management of thalassaemia in Southwestern China. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  6. Determining the authenticity of athlete urine in doping control by DNA analysis.

    PubMed

    Devesse, Laurence; Syndercombe Court, Denise; Cowan, David

    2015-10-01

    The integrity of urine samples collected from athletes for doping control is essential. The authenticity of samples may be contested, leading to the need for a robust sample identification method. DNA typing using short tandem repeats (STR) can be used for identification purposes, but its application to cellular DNA in urine has so far been limited. Here, a reliable and accurate method is reported for the successful identification of urine samples, using reduced final extraction volumes and the STR multiplex kit, Promega® PowerPlex ESI 17, with capillary electrophoretic characterisation of the alleles. Full DNA profiles were obtained for all samples (n = 20) stored for less than 2 days at 4 °C. The effect of different storage conditions on yield of cellular DNA and probability of obtaining a full profile were also investigated. Storage for 21 days at 4 °C resulted in allelic drop-out in some samples, but the random match probabilities obtained demonstrate the high power of discrimination achieved through targeting a large number of STRs. The best solution for long-term storage was centrifugation and removal of supernatant prior to freezing at -20 °C. The method is robust enough for incorporation into current anti-doping protocols, and was successfully applied to 44 athlete samples for anti-doping testing with 100% concordant typing. Copyright © 2015 John Wiley & Sons, Ltd.

  7. Determination of alkaloids in onion nectar by micellar electrokinetic chromatography.

    PubMed

    Carolina Soto, Verónica; Jofré, Viviana Patricia; Galmarini, Claudio Romulo; Silva, María Fernanda

    2016-07-01

    Nectar is the most important floral reward offered by plants to insects. Minor components such as alkaloid compounds in nectar affect bee foraging, with great influence in seed production. CE is an advantageous tool for the analysis of unexplored samples such as onion nectar due to the limited amounts of samples. Considering the importance of these compounds, a simultaneous determination of nicotine, theophylline, theobromine, caffeine, harmaline, piperine in onion nectar by MEKC-UV is herein reported. The extraction of alkaloid compounds in nectar was performed by SPE using a homemade miniaturized column (C18 ). Effects of several important factors affecting extraction efficiency as well as electrophoretic performance were investigated to acquire optimum conditions. Under the proposed conditions, the analytes can be separated within 15 min in a 50 cm effective length capillary (75 μm id) at a separation voltage of 20 kV in 20 mmol/L sodium tretraborate, 100 mmol/L SDS. The amount of sample requirement was reduced up to 2000 times, when compared to traditional methods, reaching limits of detection as low as 0.0153 ng/L. For the first time, this study demonstrates that there are marked qualitative and quantitative differences in nectar alkaloids between open pollinated and male sterile lines (MSLs) and also within MSLs. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Electrophoretic variation in low molecular weight lens crystallins from inbred strains of rats.

    PubMed

    Donner, M E; Skow, L C; Kunz, H W; Gill, T J

    1985-10-01

    Analysis of rat lens soluble proteins by analytical isoelectric focusing detected two inherited electrophoretic differences in low molecular weight (LM) crystallins from inbred strains of rats (Rattus norvegicus). The polymorphic lens crystallins were shown to be similar to a genetically variant LM crystallin, LEN-1, previously described in mice (Mus musculus) and encoded on chromosome 1, at a locus linked to Pep-3 (dipeptidase). Linkage analysis demonstrated that the rat crystallin locus was loosely linked to Pep-3 at a recombination distance of 38 +/- 4.5 U. These data suggest the conservation of a large chromosomal region during the evolution of Rodentia and support the hypothesis that the gamma-crystallins are evolving more rapidly than alpha- or beta-crystallins.

  9. [Electrophoretic patterns of cell wall protein as a criterion for the identification and classification of Corynebacteria].

    PubMed

    Mykhal's'kyĭ, L O; Furtat, I M; Dem'ianenko, F P; Kostiuchyk, A A

    2001-01-01

    Electrophoretic patterns of cell wall protein of three industrial strains, that were used for production of lysin, and eight collection strains from the genus Corynevacterium were studied to analyze their similarity as well as to estimate an opportunity of using this parameter as an additional criterion for identification and classification of corynebacteria. Similarity coefficient of cell wall overall and main protein electrophoretic patterns were determined by a specially created computer program. Electrophoretic analysis showed that every specie had an individual protein profile. There were determined biopolymers common for the specie, genus and individual among the overall majors and minors. The obtained results showed, that the patterns of main proteins were more conservative and informative in comparison with those ones of overall proteins. The definition of similarity coefficient by the main protein patterns has correlated with the protein profile characteristics of every analyzed strain, and it managed to distribute them into the separate groups. The similarity coefficient of preparations by the main protein patterns allows to separate one specie or a strain from another, and that gives us a chance to claim that this parameter could be used as an additional criterion for differentiation and referring the corynebacteria to a certain taxonomic group.

  10. A stable and convenient protein electrophoresis titration device with bubble removing system.

    PubMed

    Zhang, Qiang; Fan, Liu-Yin; Li, Wen-Lin; Cong, Feng-Song; Zhong, Ran; Chen, Jing-Jing; He, Yu-Chen; Xiao, Hua; Cao, Cheng-Xi

    2017-07-01

    Moving reaction boundary titration (MRBT) has a potential application to immunoassay and protein content analysis with high selectivity. However, air bubbles often impair the accuracy of MRBT, and the leakage of electrolyte greatly decreases the safety and convenience of electrophoretic titration. Addressing these two issues a reliable MRBT device with modified electrolyte chamber of protein titration was designed. Multiphysics computer simulation was conducted for optimization according to two-phase flow. The single chamber was made of two perpendicular cylinders with different diameters. After placing electrophoretic tube, the resident air in the junction next to the gel could be eliminated by a simple fast electrolyte flow. Removing the electrophoretic tube automatically prevented electrolyte leakage at the junction due to the gravity-induced negative pressure within the chamber. Moreover, the numerical simulation and experiments showed that the improved MRBT device has following advantages: (i) easy and rapid setup of electrophoretic tube within 20 s; (ii) simple and quick bubble dissipates from the chamber of titration within 2 s; (iii) no electrolyte leakage from the two chambers: and (iv) accurate protein titration and safe instrumental operation. The developed technique and apparatus greatly improves the performance of the previous MRBT device, and providing a new route toward practical application. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. CE-microreactor-CE-MS/MS for protein analysis

    PubMed Central

    Schoenherr, Regine M.; Ye, Mingliang; Vannatta, Michael

    2008-01-01

    We present a proof-of-principle for a fully automated bottom-up approach to protein characterization. Proteins are first separated by capillary electrophoresis. A pepsin microreactor is incorporated into the distal end of this capillary. Peptides formed in the reactor are transferred to a second capillary, where they are separated by capillary electrophoresis and characterized by mass spectrometry. While peptides generated from one digestion are being separated in the second capillary, the next protein fraction undergoes digestion in the microreactor. The migration time in the first dimension capillary is characteristic of the protein while migration time in the second dimension is characteristic of the peptide. Spot capacity for the two-dimensional separation is 590. A MS/MS analysis of a mixture of cytochrome C and myoglobin generated Mascot MOWSE scores of 107 for cytochrome C and 58 for myoglobin. The sequence coverages were 48% and 22%, respectively. PMID:17295444

  12. Statistical intensity variation analysis for rapid volumetric imaging of capillary network flux

    PubMed Central

    Lee, Jonghwan; Jiang, James Y.; Wu, Weicheng; Lesage, Frederic; Boas, David A.

    2014-01-01

    We present a novel optical coherence tomography (OCT)-based technique for rapid volumetric imaging of red blood cell (RBC) flux in capillary networks. Previously we reported that OCT can capture individual RBC passage within a capillary, where the OCT intensity signal at a voxel fluctuates when an RBC passes the voxel. Based on this finding, we defined a metric of statistical intensity variation (SIV) and validated that the mean SIV is proportional to the RBC flux [RBC/s] through simulations and measurements. From rapidly scanned volume data, we used Hessian matrix analysis to vectorize a segment path of each capillary and estimate its flux from the mean of the SIVs gathered along the path. Repeating this process led to a 3D flux map of the capillary network. The present technique enabled us to trace the RBC flux changes over hundreds of capillaries with a temporal resolution of ~1 s during functional activation. PMID:24761298

  13. Analysis of differential detergent fractions of an AtT-20 cellular homogenate using one- and two-dimensional capillary electrophoresis.

    PubMed

    Fazal, Md Abul; Palmer, Vanessa R; Dovichi, Norman J

    2006-10-20

    Differential detergent fractionation was used to sequentially extract cytosolic, membrane, nuclear, and cytoskeletal fractions from AtT-20 cells. Extracted components were denatured by sodium dodecyl sulfate (SDS) and then labeled with the fluorogenic reagent 3-(2-furoyl) quinoline-1-carboxaldehyde. Both capillary sieving electrophoresis (CSE) and micellar electrokinetic capillary chromatography (MECC) were used to separate labeled components by one-dimensional (1D) electrophoresis. Labeled components were also separated by two-dimensional (2D) capillary electrophoresis; CSE was employed in the first dimension and MECC in the second dimension. Roughly 150 fractions were transferred from the first to the second capillary for this comprehensive analysis in 2.5 h.

  14. Semi-automatic assessment of skin capillary density: proof of principle and validation.

    PubMed

    Gronenschild, E H B M; Muris, D M J; Schram, M T; Karaca, U; Stehouwer, C D A; Houben, A J H M

    2013-11-01

    Skin capillary density and recruitment have been proven to be relevant measures of microvascular function. Unfortunately, the assessment of skin capillary density from movie files is very time-consuming, since this is done manually. This impedes the use of this technique in large-scale studies. We aimed to develop a (semi-) automated assessment of skin capillary density. CapiAna (Capillary Analysis) is a newly developed semi-automatic image analysis application. The technique involves four steps: 1) movement correction, 2) selection of the frame range and positioning of the region of interest (ROI), 3) automatic detection of capillaries, and 4) manual correction of detected capillaries. To gain insight into the performance of the technique, skin capillary density was measured in twenty participants (ten women; mean age 56.2 [42-72] years). To investigate the agreement between CapiAna and the classic manual counting procedure, we used weighted Deming regression and Bland-Altman analyses. In addition, intra- and inter-observer coefficients of variation (CVs), and differences in analysis time were assessed. We found a good agreement between CapiAna and the classic manual method, with a Pearson's correlation coefficient (r) of 0.95 (P<0.001) and a Deming regression coefficient of 1.01 (95%CI: 0.91; 1.10). In addition, we found no significant differences between the two methods, with an intercept of the Deming regression of 1.75 (-6.04; 9.54), while the Bland-Altman analysis showed a mean difference (bias) of 2.0 (-13.5; 18.4) capillaries/mm(2). The intra- and inter-observer CVs of CapiAna were 2.5% and 5.6% respectively, while for the classic manual counting procedure these were 3.2% and 7.2%, respectively. Finally, the analysis time for CapiAna ranged between 25 and 35min versus 80 and 95min for the manual counting procedure. We have developed a semi-automatic image analysis application (CapiAna) for the assessment of skin capillary density, which agrees well with the classic manual counting procedure, is time-saving, and has a better reproducibility as compared to the classic manual counting procedure. As a result, the use of skin capillaroscopy is feasible in large-scale studies, which importantly extends the possibilities to perform microcirculation research in humans. © 2013.

  15. Capillary electrophoresis: principles and applications in illicit drug analysis.

    PubMed

    Tagliaro, F; Turrina, S; Smith, F P

    1996-02-09

    Capillary electrophoresis, which appeared in the early 1980s, is now rapidly expanding into many scientific disciplines, including analytical chemistry, biotechnology and biomedical and pharmaceutical sciences. In capillary electrophoresis,electrokinetic separations are carried out in tiny capillaries at high voltages (10-30 kV), thus obtaining high efficiencies (N > 10(5)) and excellent mass sensitivities (down to 10(-18)-10(-20) moles). The main features of capillary electrophoresis are: versatility of application (from inorganic ions to large DNA fragments), use of different separation modes with different selectivity, extremely low demands on sample volume, negligible running costs, possibility of interfacing with different detection systems, ruggedness and simplicity of instrumentation. Capillary electrophoresis applications in forensic sciences have appeared only recently, but are now rapidly growing, particularly in forensic toxicology. The present paper briefly describes the basic principles of capillary electrophoresis, from both the instrumental and analytical points of view. Furthermore, the main applications in the analysis of illicit/controlled drugs in both illicit preparations and biological samples are presented and discussed (43 references). It is concluded that the particular separation mechanism and the high complementarity of this technique to chromatography makes capillary electrophoresis a new powerful tool of investigation in the hands of forensic toxicologists.

  16. [Structure of newly formed capillaries of the rabbit cornea (electron microscopic study)].

    PubMed

    Gurina, O Iu; Karaganov, Ia L

    1984-08-01

    Owing to a complex application of topical analysis and tracer technique, it is possible to carry out a light optic and electron microscopic investigation of newly formed capillaries growing in the rabbit cornea after its chemical burn. The ultrastructural analysis demonstrates certain polymorphism of morphological organization of endotheliocyte in the newly formed capillaries. There is a rather elevated amount of free ribosomes, mitochondria, microtubules and microfilaments in cytoplasm. The granular endoplasmic reticulum and Golgi complex are hypertrophied. Weibel--Palade bodies appear. Taking into account certain morpho-functional peculiarities of endothelial cells along the course of the growing capillaries, on the 8th day of growth three zone are distinguished: 1--area of nondifferentiated endothelium (apex of the capillary), 2--transitional zone, 3--zone of relatively differentiated endothelium situating in the place where the capillary gets off the parental vessel. According to the zones distinguished, the ways of trans-endothelial transport of molecules are investigated. In formation of the capillary barrier-transport function an important role belongs to polymorphism of the endothelial cells along the course of the growing capillary which is determined by differentiation degree of these cells depending on their participation in permeability.

  17. Open microfluidic gel electrophoresis: Rapid and low cost separation and analysis of DNA at the nanoliter scale.

    PubMed

    Gutzweiler, Ludwig; Gleichmann, Tobias; Tanguy, Laurent; Koltay, Peter; Zengerle, Roland; Riegger, Lutz

    2017-07-01

    Gel electrophoresis is one of the most applied and standardized tools for separation and analysis of macromolecules and their fragments in academic research and in industry. In this work we present a novel approach for conducting on-demand electrophoretic separations of DNA molecules in open microfluidic (OM) systems on planar polymer substrates. The approach combines advantages of slab gel, capillary- and chip-based methods offering low consumable costs (<0.1$) circumventing cost-intensive microfluidic chip fabrication, short process times (5 min per analysis) and high sensitivity (4 ng/μL dsDNA) combined with reasonable resolution (17 bases). The open microfluidic separation system comprises two opposing reservoirs of 2-4 μL in volume, a semi-contact written gel line acting as separation channel interconnecting the reservoirs and sample injected into the line via non-contact droplet dispensing and thus enabling the precise control of the injection plug and sample concentration. Evaporation is prevented by covering aqueous structures with PCR-grade mineral oil while maintaining surface temperature at 15°C. The liquid gel line exhibits a semi-circular cross section of adaptable width (∼200-600 μm) and height (∼30-80 μm) as well as a typical length of 15-55 mm. Layout of such liquid structures is adaptable on-demand not requiring time consuming and repetitive fabrication steps. The approach was successfully demonstrated by the separation of a standard label-free DNA ladder (100-1000 bp) at 100 V/cm via in-line staining and laser induced fluorescent end-point detection using an automated prototype. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. ROMANCE: A new software tool to improve data robustness and feature identification in CE-MS metabolomics.

    PubMed

    González-Ruiz, Víctor; Gagnebin, Yoric; Drouin, Nicolas; Codesido, Santiago; Rudaz, Serge; Schappler, Julie

    2018-05-01

    The use of capillary electrophoresis coupled to mass spectrometry (CE-MS) in metabolomics remains an oddity compared to the widely adopted use of liquid chromatography. This technique is traditionally regarded as lacking the reproducibility to adequately identify metabolites by their migration times. The major reason is the variability of the velocity of the background electrolyte, mainly coming from shifts in the magnitude of the electroosmotic flow and from the suction caused by electrospray interfaces. The use of the effective electrophoretic mobility is one solution to overcome this issue as it is a characteristic feature of each compound. To date, such an approach has not been applied to metabolomics due to the complexity and size of CE-MS data obtained in such studies. In this paper, ROMANCE (RObust Metabolomic Analysis with Normalized CE) is introduced as a new software for CE-MS-based metabolomics. It allows the automated conversion of batches of CE-MS files with minimal user intervention. ROMANCE converts the x-axis of each MS file from the time into the effective mobility scale and the resulting files are already pseudo-aligned, present normalized peak areas and improved reproducibility, and can eventually follow existing metabolomic workflows. The software was developed in Scala, so it is multi-platform and computationally-efficient. It is available for download under a CC license. In this work, the versatility of ROMANCE was demonstrated by using data obtained in the same and in different laboratories, as well as its application to the analysis of human plasma samples. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Electrophoresis of a polarizable charged colloid with hydrophobic surface: A numerical study

    NASA Astrophysics Data System (ADS)

    Bhattacharyya, Somnath; Majee, Partha Sarathi

    2017-04-01

    We consider the electrophoresis of a charged colloid for a generalized situation in which the particle is considered to be polarizable and the surface exhibits hydrophobicity. The dielectric polarization of the particle creates a nonlinear dependence of the electrophoretic velocity on the applied electric field, and the core hydrophobicity amplifies the fluid convection in the Debye layer. Thus, a linear analysis is no longer applicable for this situation. The present analysis is based on the numerical solution of the nonlinear electrokinetic equations based on the Navier-Stokes-Nernst-Planck-Poisson equations coupled with the Laplace equation for the electric field within the dielectric particle. The hydrophobicity of the particle may influence its electric polarization by enhancing the convective transport of ions. The nonlinear effects, such as double-layer polarization and relaxation, are also influenced by the hydrophobicity of the particle surface. The present results compare well for a lower range of the applied electric field and surface charge density with the existing results for a perfectly dielectric particle with a hydrophobic surface based on the first-order perturbation analysis due to Khair and Squires [Phys. Fluids 21, 042001 (2009), 10.1063/1.3116664]. Dielectric polarization creates a reduction in particle electrophoretic velocity, and its impact is strong for a moderate range of Debye length. A quantitative measure of the nonlinear effects is demonstrated by comparing the electrophoretic velocity with an existing linear model.

  20. Size and DNA distributions of electrophoretically separated cultured human kidney cells

    NASA Technical Reports Server (NTRS)

    Kunze, M. E.; Plank, L. D.; Todd, P. W.

    1985-01-01

    Electrophoretic purification of purifying cultured cells according to function presumes that the size of cycle phase of a cell is not an overriding determinant of its electrophoretic velocity in an electrophoretic separator. The size distributions and DNA distributions of fractions of cells purified by density gradient electrophoresis were determined. No systematic dependence of electrophoretic migration upward in a density gradient column upon either size or DNA content were found. It was found that human leukemia cell populations, which are more uniform function and found in all phases of the cell cycle during exponential growth, separated on a vertical sensity gradient electrophoresis column according to their size, which is shown to be strictly cell cycle dependent.

  1. Hemoglobin Brigham (α2Aβ2100 Pro→Leu). HEMOGLOBIN VARIANT ASSOCIATED WITH FAMILIAL ERYTHROCYTOSIS

    PubMed Central

    Lokich, Jacob J.; Moloney, William C.; Bunn, H. Franklin; Bruckheimer, Sally M.; Ranney, Helen M.

    1973-01-01

    Erythrocytosis associated with the presence of a hemoglobin with increased oxygen affinity has been reported for 10 hemoglobin variants, most of which demonstrate altered electrophoretic mobility. Several members of a family were found to have erythrocytosis, and both the whole blood and the hemoglobin exhibited increased oxygen affinity. Phosphate-free hemoglobin solutions had a normal Bohr effect and reactivity to 2,3-diphosphoglycerate. The electrophoretic properties of the hemoglobin were normal, but on peptide mapping of a tryptic digest of the isolated β-chains, a normal βT11 peptide and an abnormal βT11 with greater Rf were seen. Analysis of the abnormal peptide showed the substitution of leucine for the normal proline at β100 (helical residue G2). The hemoglobin variant, designated Hb Brigham, serves to emphasize the necessity for detailed evaluation of the structure and function of hemoglobin in familial erythrocytosis even with electrophoretically “normal” hemoglobin. PMID:4719677

  2. Interactions of green coffee bean phenolics with wheat bread matrix in a model of simulated in vitro digestion.

    PubMed

    Świeca, Michał; Gawlik-Dziki, Urszula; Sęczyk, Łukasz; Dziki, Dariusz; Sikora, Małgorzata

    2018-08-30

    Interactions of phenolics from green coffee bean flour (GCS) with the matrix of wheat bread have been studied employing direct (electrophoretic and chromatographic techniques) and indirect tests (nutrient digestibility). According to the chromatograms of digests, the antiradical activity of enriched bread was exhibited by free phenolics. An increase the area of chromatograms and some additional peaks observed for enriched bread may confirm some interactions of proteins with phenolics. The electrophoretic profile of these extracts showed that the band corresponding to a protein with molecular mass of 38 kDA had much higher intensity in enriched bread. Electrophoretic analysis of pellets remaining after digestion revealed GCS dose-dependent differences in bands corresponding to proteins with molecular masses of 52 kDa and 23 kDa. The relative digestibility of both starch and proteins was slightly decreased by addition of GCS; however, these changes did not exceed 10%, which justifies the use of this functional material. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Electrophoretic fractional elution apparatus employing a rotational seal fraction collector

    NASA Technical Reports Server (NTRS)

    Bier, M. (Inventor)

    1977-01-01

    Electrophoretic fractional elution apparatus which has a column with a rotating seal joint is described. A thin jet of eluting buffer is directed across the lumen of the electrophoretic column in a direction perpendicular to that of electrophoretic migration. Either the content of the column is rotated with respect to the stationary jet, or the jet is rotated with respect to the column. The system may employ electrophoresis either in free solution or in packed columns.

  4. Analysis of NCAM helps identify unusual phenotypes of hereditary inclusion-body myopathy.

    PubMed

    Broccolini, A; Gidaro, T; Tasca, G; Morosetti, R; Rodolico, C; Ricci, E; Mirabella, M

    2010-07-20

    Hereditary inclusion-body myopathy or distal myopathy with rimmed vacuoles (h-IBM/DMRV) is due to mutations of the UDP-N-acetylglucosamine 2-epimerase/N-acetylmannosamine kinase (GNE) gene, which codes for an enzyme of the sialic acid biosynthetic pathway. By Western blot (WB) analysis, we have previously shown that in h-IBM/DMRV muscle, the neural cell adhesion molecule (NCAM) has increased electrophoretic mobility that reflects reduced sialylation of the protein. To identify patients with h-IBM/DMRV with atypical clinical or pathologic phenotype using NCAM analysis and the possible cellular mechanism associated with the overall abnormal sialylation of NCAM observed in this disorder. WB analysis of NCAM was performed on muscle biopsies of 84 patients with an uncharacterized muscle disorder who were divided in the following 2 groups: 1) 46 patients with a proximal muscle weakness in whom the main limb-girdle muscular dystrophy syndromes had been ruled out; and 2) 38 patients with a distal distribution of weakness in whom a neurogenic affection had been excluded. Patients in whom a reduced sialylation of NCAM was suspected were studied for the presence of GNE mutations. In 3 patients, we found that NCAM had increased electrophoretic mobility, thus suggesting an abnormal sialylation of the protein. The genetic study demonstrated that they all carried pathogenic GNE mutations. Further studies demonstrated that hyposialylated NCAM, showing increased electrophoretic mobility on WB, is expressed by nonregenerating fibers in h-IBM/DMRV muscle. WB analysis of NCAM may be instrumental in the identification of h-IBM/DMRV with atypical clinical or pathologic features.

  5. DIGE Analysis of Human Tissues.

    PubMed

    Gelfi, Cecilia; Capitanio, Daniele

    2018-01-01

    Two-dimensional difference gel electrophoresis (2-D DIGE) is an advanced and elegant gel electrophoretic analytical tool for comparative protein assessment. It is based on two-dimensional gel electrophoresis (2-DE) separation of fluorescently labeled protein extracts. The tagging procedures are designed to not interfere with the chemical properties of proteins with respect to their pI and electrophoretic mobility, once a proper labeling protocol is followed. The two-dye or three-dye systems can be adopted and their choice depends on specific applications. Furthermore, the use of an internal pooled standard makes 2-D DIGE a highly accurate quantitative method enabling multiple protein samples to be separated on the same two-dimensional gel. The image matching and cross-gel statistical analysis generates robust quantitative results making data validation by independent technologies successful.

  6. Problems with multiple use of transfer buffer in protein electrophoretic transfer.

    PubMed

    Dorri, Yaser; Kurien, Biji T; Scofield, R Hal

    2010-04-01

    Two-dimensional gel electrophoresis (2DE) and SDS-PAGE are the two most useful methods in protein separation. Proteins separated by 2DE or SDS-PAGE are usually transferred to membranes using a variety of methods, such as electrophoretic transfer, heat-mediated transfer, or nonelectrophoretic transfer, for specific protein detection and/or analysis. In a recent study, Pettegrew et al. claim to reuse transfer buffer containing methanol for at least five times for transferring proteins from SDS-PAGE to polyvinylidene difluoride. They add 150-200 ml fresh transfer solution each time for extended use as a result of loss of transfer buffer. Finally, they test efficiency of each protein transfer by chemiluminescence detection. Here, we comment on this report, as we believe this method is not accurate and useful for protein analysis, and it can cause background binding as well as inaccurate protein analysis.

  7. Field-Scale Modeling of Local Capillary Trapping During CO2 Injection into a Saline Aquifer

    NASA Astrophysics Data System (ADS)

    Ren, B.; Lake, L. W.; Bryant, S. L.

    2015-12-01

    Local capillary trapping is the small-scale (10-2 to 10+1 m) CO2 trapping that is caused by the capillary pressure heterogeneity. The benefit of LCT, applied specially to CO2 sequestration, is that saturation of stored CO2 is larger than the residual gas, yet these CO2 are not susceptible to leakage through failed seals. Thus quantifying the extent of local capillary trapping is valuable in design and risk assessment of geologic storage projects. Modeling local capillary trapping is computationally expensive and may even be intractable using a conventional reservoir simulator. In this paper, we propose a novel method to model local capillary trapping by combining geologic criteria and connectivity analysis. The connectivity analysis originally developed for characterizing well-to-reservoir connectivity is adapted to this problem by means of a newly defined edge weight property between neighboring grid blocks, which accounts for the multiphase flow properties, injection rate, and gravity effect. Then the connectivity is estimated from shortest path algorithm to predict the CO2 migration behavior and plume shape during injection. A geologic criteria algorithm is developed to estimate the potential local capillary traps based only on the entry capillary pressure field. The latter is correlated to a geostatistical realization of permeability field. The extended connectivity analysis shows a good match of CO2 plume computed by the full-physics simulation. We then incorporate it into the geologic algorithm to quantify the amount of LCT structures identified within the entry capillary pressure field that can be filled during CO2 injection. Several simulations are conducted in the reservoirs with different level of heterogeneity (measured by the Dykstra-Parsons coefficient) under various injection scenarios. We find that there exists a threshold Dykstra-Parsons coefficient, below which low injection rate gives rise to more LCT; whereas higher injection rate increases LCT in heterogeneous reservoirs. Both the geologic algorithm and connectivity analysis are very fast; therefore, the integrated methodology can be used as a quick tool to estimate local capillary trapping. It can also be used as a potential complement to the full-physics simulation to evaluate safe storage capacity.

  8. Method and apparatus for automated processing and aliquoting of whole blood samples for analysis in a centrifugal fast analyzer

    DOEpatents

    Burtis, Carl A.; Johnson, Wayne F.; Walker, William A.

    1988-01-01

    A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises (1) a whole blood sample disc, (2) a serum sample disc, (3) a sample preparation rotor, and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc in capillary tubes filled by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analytical rotor for analysis by conventional methods.

  9. Electrophoretic cell separation by means of microspheres

    NASA Technical Reports Server (NTRS)

    Smolka, A. J. K.; Nerren, B. H.; Margel, S.; Rembaum, A.

    1979-01-01

    The electrophoretic mobility of fixed human erythrocytes immunologically labeled with poly(vinylpyridine) or poly(glutaraldehyde) microspheres was reduced by approximately 40%. This observation was utilized in preparative scale electrophoretic separations of fixed human and turkey erythrocytes, the mobilities of which under normal physiological conditions do not differ sufficiently to allow their separation by continuous flow electrophoresis. We suggest that resolution in the electrophoretic separation of cell subpopulations, currently limited by finite and often overlapping mobility distributions, may be significantly enhanced by immunospecific labeling of target populations using microspheres.

  10. Recent advances in capillary ultrahigh pressure liquid chromatography.

    PubMed

    Blue, Laura E; Franklin, Edward G; Godinho, Justin M; Grinias, James P; Grinias, Kaitlin M; Lunn, Daniel B; Moore, Stephanie M

    2017-11-10

    In the twenty years since its initial demonstration, capillary ultrahigh pressure liquid chromatography (UHPLC) has proven to be one of most powerful separation techniques for the analysis of complex mixtures. This review focuses on the most recent advances made since 2010 towards increasing the performance of such separations. Improvements in capillary column preparation techniques that have led to columns with unprecedented performance are described. New stationary phases and phase supports that have been reported over the past decade are detailed, with a focus on their use in capillary formats. A discussion on the instrument developments that have been required to ensure that extra-column effects do not diminish the intrinsic efficiency of these columns during analysis is also included. Finally, the impact of these capillary UHPLC topics on the field of proteomics and ways in which capillary UHPLC may continue to be applied to the separation of complex samples are addressed. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Comprehensive protein profiling by multiplexed capillary zone electrophoresis using cross-linked polyacrylamide coated capillaries.

    PubMed

    Liu, Shaorong; Gao, Lin; Pu, Qiaosheng; Lu, Joann J; Wang, Xingjia

    2006-02-01

    We have recently developed a new process to create cross-linked polyacrylamide (CPA) coatings on capillary walls to suppress protein-wall interactions. Here, we demonstrate CPA-coated capillaries for high-efficiency (>2 x 10(6) plates per meter) protein separations by capillary zone electrophoresis (CZE). Because CPA virtually eliminates electroosmotic flow, positive and negative proteins cannot be analyzed in a single run. A "one-sample-two-separation" approach is developed to achieve a comprehensive protein analysis. High throughput is achieved through a multiplexed CZE system.

  12. Effect of AOT Microemulsion Composition on the Hydrodynamic Diameter and Electrophoretic Mobility of Titanium Oxide Nanoparticles

    NASA Astrophysics Data System (ADS)

    Shaparenko, N. O.; Beketova, D. I.; Demidova, M. G.; Bulavchenko, A. I.

    2018-05-01

    The hydrodynamic diameter and electrophoretic mobility of titania nanoparticles in AOT microemulsions are studied depending on their water content (from 0 to 1.5 vol %), chloroform content in n-decane-chloroform mixture (from 0 to 30 vol %) and temperature (from 0 to 60°C). Considerable changes in diameter (from 20 to 400 nm) are detected upon adding water to the microemulsion. The electrophoretic mobility grows by 2-3 times upon adding chloroform, or as the temperature falls. The observed features allow us to halve the time of electrophoretic concentration for 140 nm TiO2 nanoparticles, and to concentrate 14 nm nanoparticles that do not exhibit electrophoretic mobility in the absence of chloroform.

  13. A microchip electrophoresis-mass spectrometric platform with double cell lysis nano-electrodes for automated single cell analysis.

    PubMed

    Li, Xiangtang; Zhao, Shulin; Hu, Hankun; Liu, Yi-Ming

    2016-06-17

    Capillary electrophoresis-based single cell analysis has become an essential approach in researches at the cellular level. However, automation of single cell analysis has been a challenge due to the difficulty to control the number of cells injected and the irreproducibility associated with cell aggregation. Herein we report the development of a new microfluidic platform deploying the double nano-electrode cell lysis technique for automated analysis of single cells with mass spectrometric detection. The proposed microfluidic chip features integration of a cell-sized high voltage zone for quick single cell lysis, a microfluidic channel for electrophoretic separation, and a nanoelectrospray emitter for ionization in MS detection. Built upon this platform, a microchip electrophoresis-mass spectrometric method (MCE-MS) has been developed for automated single cell analysis. In the method, cell introduction, cell lysis, and MCE-MS separation are computer controlled and integrated as a cycle into consecutive assays. Analysis of large numbers of individual PC-12 neuronal cells (both intact and exposed to 25mM KCl) was carried out to determine intracellular levels of dopamine (DA) and glutamic acid (Glu). It was found that DA content in PC-12 cells was higher than Glu content, and both varied from cell to cell. The ratio of intracellular DA to Glu was 4.20±0.8 (n=150). Interestingly, the ratio drastically decreased to 0.38±0.20 (n=150) after the cells are exposed to 25mM KCl for 8min, suggesting the cells released DA promptly and heavily while they released Glu at a much slower pace in response to KCl-induced depolarization. These results indicate that the proposed MCE-MS analytical platform may have a great potential in researches at the cellular level. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Controlled method of reducing electrophoretic mobility of macromolecules, particles, or cells

    NASA Technical Reports Server (NTRS)

    Vanalstine, James M. (Inventor)

    1992-01-01

    A method of reducing electrophoretic mobility of macromolecules, particles, cells, and other substances is provided which comprises interacting in a conventional electrophoretic separating procedure, the substances with a polymer-linked affinity compound comprised of a hydrophilic neutral polymer such as polyethylene glycol bound to a second component such as a hydrophobic compound, an immunocompound such as an antibody or antibody active fragment, or a ligand such as a hormone, drug, antigen, or a hapten. The reduction of electrophoretic mobility achieved is directly proportional to the concentration of the polymer-linked affinity compound employed, and such reduction can comprise up to 100 percent for particular particles and cells. The present invention is advantageous in that electrophoretic separation can now be achieved for substances whose native surface charge structure had prevented them from being separated by normal electrophoretic means. Depending on the affinity component utilized, separation can be achieved on the basis of the specific/irreversible, specific/reversible, semi-specific/reversible, relatively nonspecific/reversible, or relatively nonspecific/irreversible ligand-substance interactions.

  15. On the Asymmetric Focusing of Low-Emittance Electron Bunches via Active Lensing by Using Capillary Discharges

    NASA Astrophysics Data System (ADS)

    Bulanov, Stepan; Bagdasarov, Gennadiy; Bobrova, Nadezhda; Boldarev, Alexey; Olkhovskaya, Olga; Sasorov, Pavel; Gasilov, Vladimir; Barber, Samuel; Gonsalves, Anthony; Schroeder, Carl; van Tilborg, Jeroen; Esarey, Eric; Leemans, Wim; Levato, Tadzio; Margarone, Daniele; Korn, Georg; Kando, Masaki; Bulanov, Sergei

    2017-10-01

    A novel method for asymmetric focusing of electron beams is proposed. The scheme is based on the active lensing technique, which takes advantage of the strong inhomogeneous magnetic field generated inside the capillary discharge plasma to focus the ultrarelativistic electrons. The plasma and magnetic field parameters inside a capillary discharge are described theoretically and modeled with dissipative MHD simulations to enable analysis of capillaries of oblong rectangle cross-sections implying that large aspect ratio rectangular capillaries can be used to form flat electron bunches. The effect of the capillary cross-section on the electron beam focusing properties were studied using the analytical methods and simulation- derived magnetic field map showing the range of the capillary discharge parameters required for producing the high quality flat electron beams.

  16. Seed protein variations of Salicornia L. and allied taxa in Turkey.

    PubMed

    Yaprak, A E; Yurdakulol, E

    2007-06-01

    Electrophoretic seed protein patterns of a number of accessions of Salicornia europaea L. sl., S. prostrata Palas, S. fragilis P.W. Ball and Tutin, Sarcocornia fruticosa (L.) A. J. Scott, Sarcocornia perennis (Miller.) A. J. Scott, Arthrocnemum glaucum (Del.) Ung.-Sternb., Microcnemum coralloides (Loscos and Pardo) subsp. anatolicum Wagenitz and Halocnemum strobilaceum (Pall.) Bieb. were electrophoretically analysed on SDS-PAGE. In total 48 different bands were identified. The obtained data have been treated numerically using the cluster analysis method of unweighted pair group (UPGMA). Finally it was determined that all species separated according to seed protein profiles. And the cladogram obtained studied taxa have been given.

  17. P39-T Analysis of Oligosaccharides by Capillary-Scale High-Performance Anion-Exchange Chromatography with Pulsed Amperometric Detection (CHPAEC-PAD) and On-Line Electrospray-Ionization Ion-Trap Mass Spectrometry (CHPAEC-ITMS)

    PubMed Central

    Bruggink, C.; Koeleman, C.; Barreto, V.; Lui, Y.; Pohl, C.; Ingendoh, A.; Wuhrer, M.; Hokke, C.; Deelder, A.

    2007-01-01

    High-pH anion-exchange chromatography with pulsed amperometric detection (HPAEC-PAD) is an established technique for selective separation and analysis of underivatized carbohydrates. The miniaturization of chromatographic techniques by means of capillary columns, and on-line coupling to mass spectrometry are critical to the further development of glycan analysis methods that are compatible with the current requirements in clinical settings. A system has been developed based on the Dionex BioLC equipped with a microbore gradient pump with PEEK flow splitter, a FAMOS micro autosampler, a modified electrochemical cell for on-line capillary PAD, and a capillary column (380 μm i.d.) packed with a new type of anion-exchange resin. This system operates with sensitivity in the low femtomol range. In addition, an on-line capillary desalter has been developed to allow direct coupling to the Bruker Esquire 3000 ion-trap mass spectrometer with electrospray ionization interface (ESI-IT-MS). Both systems have been evaluated using oligosaccharide standards as well as urine samples exhibiting various lysosomal oligosaccharide storage diseases. Initial data indicate that the robust and selective anion-exchange system, in combination with ESI-IT-MS for structure confirmation and analysis, provides a powerful platform that complements existing nano/capillary LC-MS methods for analytical determination of oligosaccharides in biological matrices.

  18. Heuristic approach to capillary pressures averaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coca, B.P.

    1980-10-01

    Several methods are available to average capillary pressure curves. Among these are the J-curve and regression equations of the wetting-fluid saturation in porosity and permeability (capillary pressure held constant). While the regression equation seem completely empiric, the J-curve method seems to be theoretically sound due to its expression based on a relation between the average capillary radius and the permeability-porosity ratio. An analysis is given of each of these methods.

  19. Capillary Electrophoresis Analysis of Cations in Water Samples: An Experiment for the Introductory Laboratory

    ERIC Educational Resources Information Center

    Pursell, Christopher J.; Chandler, Bert; Bushey, Michelle M.

    2004-01-01

    Capillary electrophoresis is gradually working its way into the undergraduate laboratory curriculum. Typically, experiments utilizing this newer technology have been introduced into analytical or instrumental courses. The authors of this article have introduced an experiment into the introductory laboratory that utilizes capillary electrophoresis…

  20. Electrophoretic cell separation by means of immunomicrospheres

    NASA Technical Reports Server (NTRS)

    Rembaum, A.; Smolka, A. J. K.

    1980-01-01

    The electrophoretic mobility of fixed human red blood cells immunologically labeled with polymeric (4-vinyl)pyridine or polyglutaraldehyde microspheres was altered to a considerable extent. This observation was utilized in the preparative scale electrophoretic separation of human and turkey fixed red blood cells, whose mobilities under normal physiological conditions do not differ sufficiently to allow their separation by continuous flow electrophoresis. It is suggested that resolution in the electrophoretic separation of cell subpopulations, currently limited by finite and often overlapping mobility distributions, may be significantly enhanced by immuno-specific labeling of target populations using microspheres.

  1. Comparisons Between Histology and Optical Coherence Tomography Angiography of the Periarterial Capillary-Free Zone.

    PubMed

    Balaratnasingam, Chandrakumar; An, Dong; Sakurada, Yoichi; Lee, Cecilia S; Lee, Aaron Y; McAllister, Ian L; Freund, K Bailey; Sarunic, Marinko; Yu, Dao-Yi

    2018-05-01

    To use the capillary-free zone along retinal arteries, a physiologic area of superficial avascularization, as an anatomic paradigm to investigate the reliability of optical coherence tomography angiography (OCTA) for visualizing the deep retinal circulation. Validity analysis and laboratory investigation. Five normal human donor eyes (mean age 69.8 years) were perfusion-labeled with endothelial antibodies and the capillary networks of the perifovea were visualized using confocal scanning laser microscopy. Regions of the capillary-free zone along the retinal artery were imaged using OCTA in 16 normal subjects (age range 24-51 years). Then, 3 × 3-mm scans were acquired using the RTVue XR Avanti (ver. 2016.1.0.26; Optovue, Inc, Fremont, California, USA), PLEX Elite 9000 (ver. 1.5.0.15909; Zeiss Meditec, Inc, Dublin, California, USA), Heidelberg Spectralis OCT2 (Family acquisition module 6.7.21.0; Heidelberg Engineering, Heidelberg, Germany), and DRI-OCT Triton (Ver. 1.1.1; Topcon Corp, Tokyo, Japan). Images of the superficial plexus, deep vascular plexus, and a slab containing all vascular plexuses were generated using manufacturer-recommended default settings. Comparisons between histology and OCTA were performed. Histologic analysis revealed that the capillary-free zone along the retinal artery was confined to the plane of the superficial capillary plexus and did not include the intermediate and deep capillary plexuses. Images derived from OCTA instruments demonstrated a prominent capillary-free zone along the retinal artery in slabs of the superficial plexus, deep plexus, and all capillary plexuses. The number of deep retinal capillaries seen in the capillary-free zone was significantly greater on histology than on OCTA (P < .001). Using the capillary-free zone as an anatomic paradigm, we show that the deep vascular beds of the retina are not completely visualized using OCTA. This may be a limitation of current OCTA techniques. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. A star-shaped poly(2-methyl-2-oxazoline)-based antifouling coating: Application in investigation of the interaction between acetaminophen and bovine serum albumin by frontal analysis capillary electrophoresis.

    PubMed

    Du, Haiqin; Zhang, Chong; Mao, Ke; Wang, Yanmei

    2017-08-01

    In this work, an antifouling capillary modified with star-shaped poly(2-methyl-2-oxazoline)-based copolymer was used to study the interaction between acetaminophen (APAP) and bovine serum albumin (BSA) by frontal analysis capillary electrophoresis (FACE). The star-shaped copolymer, poly(ethylene imine)-graft-poly(2-methyl-2-oxazoline) (PEI-g-PMOXA), was immobilized onto the fused-silica capillary inner wall via dopamine-assisted co-deposition strategy, yielding a PEI-g-PMOXA/polydopamine (PDA)-coated antifouling capillary, i.e., an antifouling capillary coated with the PEI-g-PMOXA/PDA co-deposited film. Electroosmotic flow (EOF) mobility of the PEI-g-PMOXA/PDA-coated capillary was almost zero in a wide pH range (3.0-10.0), while the EOF mobility of bare capillary was much larger and increased significantly with pH increasing. When the PEI-g-PMOXA/PDA-coated capillary was exploited to separate a protein mixture including cytochrome c, lysozyme, ribonuclease A and α-chymotrypsinogen A, the theoretical plate numbers were of five orders of magnitude which were about ten-fold higher over those obtained with bare capillary; in addition, the RSD values of migration time were mostly less than 0.7% (30 consecutive runs) which were much smaller than those of bare capillary (c.a. 5.7%). The protein-resistant PEI-g-PMOXA/PDA-coated capillary was then used to investigate the interaction between APAP and BSA by FACE, the binding constant and number of binding sites at 25°C and pH 7.4 (Tris/HCl buffer of 25mM) were 1.39×10 4 M -1 and 1.08, respectively, which were comparable to the results determined by fluorescence spectroscopic measurement (3.18×10 4 M -1 and 1.19, respectively). Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Capillary electrophoresis for drug analysis

    NASA Astrophysics Data System (ADS)

    Lurie, Ira S.

    1999-02-01

    Capillary electrophoresis (CE) is a high resolution separation technique which is amenable to a wide variety of solutes, including compounds which are thermally degradable, non-volatile and highly polar, and is therefore well suited for drug analysis. Techniques which have been used in our laboratory include electrokinetic chromatography (ECC), free zone electrophoresis (CZE) and capillary electrochromatography (CEC). ECC, which uses a charged run buffer additive which migrates counter to osmotic flow, is excellent for many applications, including, drug screening and analyses of heroin, cocaine and methamphetamine samples. ECC approaches include the use of micelles and charged cyclodextrins, which allow for the separation of complex mixtures. Simultaneous separation of acidic, neutral and basic solutes and the resolution of optical isomers and positional isomers are possible. CZE has been used for the analysis of small ions (cations and anions) in heroin exhibits. For the ECC and CZE experiments performed in our laboratory, uncoated capillaries were used. In contrast, CEC uses capillaries packed with high performance liquid chromatography stationary phases, and offers both high peak capacities and unique selectivities. Applications include the analysis of cannabinoids and drug screening. Although CE suffers from limited concentration sensitivity, it is still applicable to trace analysis of drug samples, especially when using injection techniques such as stacking, or detection schemes such as laser induced fluorescence and extended pathlength UV.

  4. Electrophoretic Deposition of Hydroxyapatite Film Containing Re-Doped MoS₂ Nanoparticles.

    PubMed

    Shalom, Hila; Feldman, Yishay; Rosentsveig, Rita; Pinkas, Iddo; Kaplan-Ashiri, Ifat; Moshkovich, Alexey; Perfilyev, Vladislav; Rapoport, Lev; Tenne, Reshef

    2018-02-26

    Films combining hydroxyapatite (HA) with minute amounts (ca. 1 weight %) of (rhenium doped) fullerene-like MoS₂ (IF) nanoparticles were deposited onto porous titanium substrate through electrophoretic process (EPD). The films were analyzed by scanning electron microscopy (SEM), X-ray diffraction and Raman spectroscopy. The SEM analysis showed relatively uniform coatings of the HA + IF on the titanium substrate. Chemical composition analysis using energy dispersive X-ray spectroscopy (EDS) of the coatings revealed the presence of calcium phosphate minerals like hydroxyapatite, as a majority phase. Tribological tests were undertaken showing that the IF nanoparticles endow the HA film very low friction and wear characteristics. Such films could be of interest for various medical technologies. Means for improving the adhesion of the film to the underlying substrate and its fracture toughness, without compromising its biocompatibility are discussed at the end.

  5. Electrophoretic deposition and electrochemical behavior of novel graphene oxide-hyaluronic acid-hydroxyapatite nanocomposite coatings

    NASA Astrophysics Data System (ADS)

    Li, Ming; Liu, Qian; Jia, Zhaojun; Xu, Xuchen; Shi, Yuying; Cheng, Yan; Zheng, Yufeng; Xi, Tingfei; Wei, Shicheng

    2013-11-01

    Novel ternary graphene oxide-hyaluronic acid-hydroxyapatite (GO-HY-HA) nanocomposite coatings were prepared on Ti substrate using anodic electrophoretic deposition (EPD). Hyaluronic acid was employed as charging additive and dispersion agent during EPD. The kinetics and mechanism of the deposition, and the microstructure of the coated samples were investigated using scanning electron microscopy, X-ray diffraction, Raman spectrum, thermo-gravimetric analysis, and microscopic Fourier transform infrared analysis. The results showed that the addition of GO sheets into the HY-HA suspensions could increase the deposition rate and inhibit cracks creation and propagation in the coatings. The corrosion resistant of the resulting samples were evaluated using potentiodynamic polarization method in simulated body fluid, and the GO-HY-HA coatings could effectively improve the anti-corrosion property of the Ti substrate.

  6. Multichannel Mars Organic Analyzer (McMOA): Microfluidic Networks for the Automated In Situ Microchip Electrophoretic Analysis of Organic Biomarkers on Mars

    NASA Astrophysics Data System (ADS)

    Chiesl, T. N.; Benhabib, M.; Stockton, A. M.; Mathies, R. A.

    2010-04-01

    We present the Multichannel Mars Organic Analyzer (McMOA) for the analysis of Amino Acids, PAHs, and Oxidized Carbon. Microfluidic architecures integrating automated metering, mixing, on chip reactions, and serial dilutions are also discussed.

  7. Electrophoretic separator for purifying biologicals, part 1

    NASA Technical Reports Server (NTRS)

    Mccreight, L. R.

    1978-01-01

    A program to develop an engineering model of an electrophoretic separator for purifying biologicals is summarized. An extensive mathematical modeling study and numerous ground based tests were included. Focus was placed on developing an actual electrophoretic separator of the continuous flow type, configured and suitable for flight testing as a space processing applications rocket payload.

  8. A DC electrophoresis method for determining electrophoretic mobility through the pressure driven negation of electro osmosis

    NASA Astrophysics Data System (ADS)

    Karam, Pascal; Pennathur, Sumita

    2016-11-01

    Characterization of the electrophoretic mobility and zeta potential of micro and nanoparticles is important for assessing properties such as stability, charge and size. In electrophoretic techniques for such characterization, the bulk fluid motion due to the interaction between the fluid and the charged surface must be accounted for. Unlike current industrial systems which rely on DLS and oscillating potentials to mitigate electroosmotic flow (EOF), we propose a simple alternative electrophoretic method for optically determining electrophoretic mobility using a DC electric fields. Specifically, we create a system where an adverse pressure gradient counters EOF, and design the geometry of the channel so that the flow profile of the pressure driven flow matches that of the EOF in large regions of the channel (ie. where we observe particle flow). Our specific COMSOL-optimized geometry is two large cross sectional areas adjacent to a central, high aspect ratio channel. We show that this effectively removes EOF from a large region of the channel and allows for the accurate optical characterization of electrophoretic particle mobility, no matter the wall charge or particle size.

  9. A Rapid Method for Optimizing Running Temperature of Electrophoresis through Repetitive On-Chip CE Operations

    PubMed Central

    Kaneda, Shohei; Ono, Koichi; Fukuba, Tatsuhiro; Nojima, Takahiko; Yamamoto, Takatoki; Fujii, Teruo

    2011-01-01

    In this paper, a rapid and simple method to determine the optimal temperature conditions for denaturant electrophoresis using a temperature-controlled on-chip capillary electrophoresis (CE) device is presented. Since on-chip CE operations including sample loading, injection and separation are carried out just by switching the electric field, we can repeat consecutive run-to-run CE operations on a single on-chip CE device by programming the voltage sequences. By utilizing the high-speed separation and the repeatability of the on-chip CE, a series of electrophoretic operations with different running temperatures can be implemented. Using separations of reaction products of single-stranded DNA (ssDNA) with a peptide nucleic acid (PNA) oligomer, the effectiveness of the presented method to determine the optimal temperature conditions required to discriminate a single-base substitution (SBS) between two different ssDNAs is demonstrated. It is shown that a single run for one temperature condition can be executed within 4 min, and the optimal temperature to discriminate the SBS could be successfully found using the present method. PMID:21845077

  10. Modeling of protein electrophoresis in silica colloidal crystals having brush layers of polyacrylamide

    PubMed Central

    Birdsall, Robert E.; Koshel, Brooke M.; Hua, Yimin; Ratnayaka, Saliya N.; Wirth, Mary J.

    2013-01-01

    Sieving of proteins in silica colloidal crystals of mm dimensions is characterized for particle diameters of nominally 350 and 500 nm, where the colloidal crystals are chemically modified with a brush layer of polyacrylamide. A model is developed that relates the reduced electrophoretic mobility to the experimentally measurable porosity. The model fits the data with no adjustable parameters for the case of silica colloidal crystals packed in capillaries, for which independent measurements of the pore radii were made from flow data. The model also fits the data for electrophoresis in a highly ordered colloidal crystal formed in a channel, where the unknown pore radius was used as a fitting parameter. Plate heights as small as 0.4 μm point to the potential for miniaturized separations. Band broadening increases as the pore radius approaches the protein radius, indicating that the main contribution to broadening is the spatial heterogeneity of the pore radius. The results quantitatively support the notion that sieving occurs for proteins in silica colloidal crystals, and facilitate design of new separations that would benefit from miniaturization. PMID:23229163

  11. ANALYSIS OF ANIONIC METALLIZED AZO AND FORMAZAN DYES BY CAPILLARY ELECTROPHORESIS/MASS SPECTROMETRY

    EPA Science Inventory

    Capillary electrophoresis-mass spectrometry was applied to the separation of several anionic dyes containing copper(II), chromium(III), or cobalt(III) as part of the dye molecule. The dyes were separated using a 110 cmX50 mu m uncoated fused-silica capillary and a 5 mM ammonium a...

  12. Effect of hypothermic pulmonary artery flushing on capillary filtration coefficient.

    PubMed

    Andrade, R S; Wangensteen, O D; Jo, J K; Tsai, M Y; Bolman, R M

    2000-07-27

    We previously demonstrated that surfactant dilution and inhibition occur immediately after pulmonary artery flushing with hypothermic modified Euro-Collins solution. Consequently, we speculated that increased capillary permeability contributed to these surfactant changes. To test this hypothesis, we evaluated the effects of hypothermic pulmonary artery flushing on the pulmonary capillary filtration coefficient (Kfc), and additionally performed a biochemical analysis of surfactant. We used a murine isolated, perfused lung model to measure the pulmonary capillary filtration coefficient and hemodynamic parameters, to determine the wet to dry weight ratio, and to evaluate surfactant by biochemical analysis of lung lavage fluid. We defined three study groups. In group I (controls), we harvested lungs without hypothermic pulmonary artery flushing, and measured Kfc immediately. In group II (in situ flush), we harvested lungs after hypothermic pulmonary artery flushing with modified Euro-Collins solution, and then measured Kfc. Experiments in groups I and II were designed to evaluate persistent changes in Kfc after pulmonary artery flushing. In group III (ex vivo flush), we flushed lungs ex vivo to evaluate transient changes in Kfc during hypothermic pulmonary artery flushing. Groups I and II did not differ significantly in capillary filtration coefficient and hemodynamics. Group II showed significant alterations on biochemical surfactant analysis and a significant increase in wet-to-dry weight ratio, when compared with group I. In group III, we observed a significant transient increase in capillary filtration coefficient during pulmonary artery flushing. Hypothermic pulmonary artery flushing transiently increases the capillary filtration coefficient, leads to an increase in the wet to dry weight ratio, and induces biochemical surfactant changes. These findings could be explained by the effects of hypothermic modified Euro-Collins solution on pulmonary capillary permeability.

  13. On-line DNA analysis system with rapid thermal cycling

    DOEpatents

    Swerdlow, Harold P.; Wittwer, Carl T.

    1999-01-01

    An apparatus particularly suited for subjecting biological samples to any necessary sample preparation tasks, subjecting the sample to rapid thermal cycling, and then subjecting the sample to subsequent on-line analysis using one or more of a number of analytical techniques. The apparatus includes a chromatography device including an injection means, a chromatography pump, and a chromatography column. In addition, the apparatus also contains a capillary electrophoresis device consisting of a capillary electrophoresis column with an inlet and outlet end, a means of injection, and means of applying a high voltage to cause the differential migration of species of interest through the capillary column. Effluent from the liquid chromatography column passes over the inlet end of the capillary electrophoresis column through a tee structure and when the loading of the capillary electrophoresis column is desired, a voltage supply is activated at a precise voltage and polarity over a specific duration to cause sample species to be diverted from the flowing stream to the capillary electrophoresis column. A laser induced fluorescence detector preferably is used to analyze the products separated while in the electrophoresis column.

  14. On-line DNA analysis system with rapid thermal cycling

    DOEpatents

    Swerdlow, H.P.; Wittwer, C.T.

    1999-08-10

    This application describes an apparatus particularly suited for subjecting biological samples to any necessary sample preparation tasks, subjecting the sample to rapid thermal cycling, and then subjecting the sample to subsequent on-line analysis using one or more of a number of analytical techniques. The apparatus includes a chromatography device including an injection means, a chromatography pump, and a chromatography column. In addition, the apparatus also contains a capillary electrophoresis device consisting of a capillary electrophoresis column with an inlet and outlet end, a means of injection, and means of applying a high voltage to cause the differential migration of species of interest through the capillary column. Effluent from the liquid chromatography column passes over the inlet end of the capillary electrophoresis column through a tee structure and when the loading of the capillary electrophoresis column is desired, a voltage supply is activated at a precise voltage and polarity over a specific duration to cause sample species to be diverted from the flowing stream to the capillary electrophoresis column. A laser induced fluorescence detector preferably is used to analyze the products separated while in the electrophoresis column. 6 figs.

  15. Capillary electrophoresis-electrospray ionization-mass spectrometry method to determine the phenolic fraction of extra-virgin olive oil.

    PubMed

    Carrasco-Pancorbo, Alegría; Arráez-Román, David; Segura-Carretero, Antonio; Fernández-Gutiérrez, Alberto

    2006-06-01

    We describe the first analytical method involving SPE and CZE coupled to ESI-IT MS (CZE-ESI-MS) used to identify and characterize phenolic compounds in olive oil samples. The SPE, CZE and ESI-MS parameters were optimized in order to maximize the number of phenolic compounds detected and the sensitivity of their determination. To this end we have devised a detailed method to find the best conditions for CE separation and the detection by MS of the phenolic compounds present in olive oil using a methanol-water extract of Picual extra-virgin olive oil (VOO). Electrophoretic separation was carried out using an aqueous CE buffer system consisting of 60 mM NH(4)OAc at pH 9.5 with 5% of 2-propanol, a sheath liquid containing 2-propanol/water 60:40 v/v and 0.1% v/v triethylamine. This method offers to the analyst the chance to study important phenolic compounds such as phenolic alcohols (tyrosol (TY), hydroxytyrosol (HYTY) and 2-(4-hydroxyphenyl)ethyl acetate), lignans ((+)-pinoresinol and (+)-1-acetoxypinoresinol), complex phenols (ligstroside aglycon (Lig Agl), oleuropein aglycon, their respective decarboxylated derivatives and several isomeric forms of these (dialdehydic form of oleuropein aglycon, dialdehydic form of ligstroside aglycon, dialdehydic form of decarboxymethyl elenolic acid linked to HYTY, dialdehydic form of decarboxymethyl elenolic acid linked to TY) and 10-hydroxy-oleuropein aglycon) and one other phenolic compound (elenolic acid) in extra-VOO by using a simple SPE before CE-ESI-MS analysis.

  16. Ensemble of electrophoretically captured gold nanoparticles as a fingerprint of Boltzmann velocity distribution

    NASA Astrophysics Data System (ADS)

    Hong, S. H.; Kang, M. G.; Lim, J. H.; Hwang, S. W.

    2008-07-01

    An ensemble of electrophoretically captured gold nanoparticles is exploited to fingerprint their velocity distribution in solution. The electrophoretic capture is performed using a dc biased nanogap electrode, and panoramic scanning electron microscopic images are inspected to obtain the regional density of the captured gold nanoparticles. The regional density profile along the surface of the electrode is in a quantitative agreement with the calculated density of the captured nanoparticles. The calculated density is obtained by counting, in the Boltzmann distribution, the number of nanoparticles whose thermal velocity is smaller than the electrophoretic velocity.

  17. Cell and Particle Interactions and Aggregation During Electrophoretic Motion

    NASA Technical Reports Server (NTRS)

    Wang, Hua; Zeng, Shulin; Loewenberg, Michael; Todd, Paul; Davis, Robert H.

    1996-01-01

    The stability and pairwise aggregation rates of small spherical particles under the collective effects of buoyancy-driven motion and electrophoretic migration are analyzed. The particles are assumed to be non-Brownian, with thin double-layers and different zeta potentials. The particle aggregation rates may be enhanced or reduced, respectively, by parallel and antiparallel alignments of the buoyancy-driven and electrophoretic velocities. For antiparallel alignments, with the buoyancy-driven relative velocity exceeding the electrophoretic relative velocity between two widely-separated particles, there is a 'collision-forbidden region' in parameter space due to hydrodynamic interactions; thus, the suspension becomes stable against aggregation.

  18. Electrophoretic fabrication of chitosan-zirconium-oxide nanobiocomposite platform for nucleic acid detection.

    PubMed

    Das, Maumita; Dhand, Chetna; Sumana, Gajjala; Srivastava, A K; Nagarajan, R; Nain, Lata; Iwamoto, M; Manaka, Takaaki; Malhotra, B D

    2011-03-14

    The present work describes electrophoretic fabrication of nanostructured chitosan-zirconium-oxide composite (CHIT-NanoZrO(2)) film (180 nm) onto indium-tin-oxide (ITO)-coated glass plate. This nanobiocomposite film has been explored as immobilization platform for probe DNA specific to M. Tuberculosis as model biomolecule to investigate its sensing characteristics. It is revealed that pH-responsive behavior of CHIT and its cationic skeleton is responsible for the movement of CHIT-NanoZrO(2) colloids toward cathode during electrophoretic deposition. The FT-IR, SEM, TEM, and EDX techniques have been employed for the structural, morphological, and composition analysis of the fabricated electrodes. The morphological studies clearly reveal uniform inter-linking and dispersion of hexagonal nanograins of ZrO(2) (30-50 nm) into the chitosan matrix, resulting in homogeneous nanobiocomposite formation. Electrochemical response measurements of DNA/CHIT-NanoZrO(2)/ITO bioelectrode, carried out using cyclic voltammetry and differential pulse voltammetry, reveal that this bioelectrode can specifically detect complementary target DNA up to 0.00078 μM with sensitivity of 6.38 × 10(-6) AμM(-1).

  19. Quantitative twoplex glycan analysis using 12C6 and 13C6 stable isotope 2-aminobenzoic acid labelling and capillary electrophoresis mass spectrometry.

    PubMed

    Váradi, Csaba; Mittermayr, Stefan; Millán-Martín, Silvia; Bones, Jonathan

    2016-12-01

    Capillary electrophoresis (CE) offers excellent efficiency and orthogonality to liquid chromatographic (LC) separations for oligosaccharide structural analysis. Combination of CE with high resolution mass spectrometry (MS) for glycan analysis remains a challenging task due to the MS incompatibility of background electrolyte buffers and additives commonly used in offline CE separations. Here, a novel method is presented for the analysis of 2-aminobenzoic acid (2-AA) labelled glycans by capillary electrophoresis coupled to mass spectrometry (CE-MS). To ensure maximum resolution and excellent precision without the requirement for excessive analysis times, CE separation conditions including the concentration and pH of the background electrolyte, the effect of applied pressure on the capillary inlet and the capillary length were evaluated. Using readily available 12/13 C 6 stable isotopologues of 2-AA, the developed method can be applied for quantitative glycan profiling in a twoplex manner based on the generation of extracted ion electropherograms (EIE) for 12 C 6 'light' and 13 C 6 'heavy' 2-AA labelled glycan isotope clusters. The twoplex quantitative CE-MS glycan analysis platform is ideally suited for comparability assessment of biopharmaceuticals, such as monoclonal antibodies, for differential glycomic analysis of clinical material for potential biomarker discovery or for quantitative microheterogeneity analysis of different glycosylation sites within a glycoprotein. Additionally, due to the low injection volume requirements of CE, subsequent LC-MS analysis of the same sample can be performed facilitating the use of orthogonal separation techniques for structural elucidation or verification of quantitative performance.

  20. On production and asymmetric focusing of flat electron beams using rectangular capillary discharge plasmas

    DOE PAGES

    Bagdasarov, G. A.; Bobrova, N. A.; Boldarev, A. S.; ...

    2017-12-27

    A method for the asymmetric focusing of electron bunches, based on the active plasma lensing technique is proposed. Our method takes advantage of the strong inhomogeneous magnetic field generated inside the capillary discharge plasma to focus the ultrarelativistic electrons. The plasma and magnetic field parameters inside the capillary discharge are described theoretically and modeled with dissipative magnetohydrodynamic computer simulations enabling analysis of the capillaries of rectangle cross-sections. We could use large aspect ratio rectangular capillaries to transport electron beams with high emittance asymmetries, as well as assist in forming spatially flat electron bunches for final focusing before the interaction point.

  1. On production and asymmetric focusing of flat electron beams using rectangular capillary discharge plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bagdasarov, G. A.; Bobrova, N. A.; Boldarev, A. S.

    A method for the asymmetric focusing of electron bunches, based on the active plasma lensing technique is proposed. Our method takes advantage of the strong inhomogeneous magnetic field generated inside the capillary discharge plasma to focus the ultrarelativistic electrons. The plasma and magnetic field parameters inside the capillary discharge are described theoretically and modeled with dissipative magnetohydrodynamic computer simulations enabling analysis of the capillaries of rectangle cross-sections. We could use large aspect ratio rectangular capillaries to transport electron beams with high emittance asymmetries, as well as assist in forming spatially flat electron bunches for final focusing before the interaction point.

  2. On production and asymmetric focusing of flat electron beams using rectangular capillary discharge plasmas

    NASA Astrophysics Data System (ADS)

    Bagdasarov, G. A.; Bobrova, N. A.; Boldarev, A. S.; Olkhovskaya, O. G.; Sasorov, P. V.; Gasilov, V. A.; Barber, S. K.; Bulanov, S. S.; Gonsalves, A. J.; Schroeder, C. B.; van Tilborg, J.; Esarey, E.; Leemans, W. P.; Levato, T.; Margarone, D.; Korn, G.; Kando, M.; Bulanov, S. V.

    2017-12-01

    A method for the asymmetric focusing of electron bunches, based on the active plasma lensing technique, is proposed. This method takes advantage of the strong inhomogeneous magnetic field generated inside the capillary discharge plasma to focus on the ultrarelativistic electrons. The plasma and magnetic field parameters inside the capillary discharge are described theoretically and modeled with dissipative magnetohydrodynamic computer simulations enabling analysis of the capillaries of rectangle cross-sections. Large aspect ratio rectangular capillaries might be used to transport electron beams with high emittance asymmetries, as well as assist in forming spatially flat electron bunches for final focusing before the interaction point.

  3. Analytical study of electrophoretic characterization of kidney cells. [conducted during the Apollo Soyuz Test Project

    NASA Technical Reports Server (NTRS)

    Knox, R. J.

    1978-01-01

    Embryonic kidney cells were studied as a follow-up to the MA-011 Electrophoresis Technology Experiment which was conducted during the Apollo Soyuz Test Project (ASTP). The postflight analysis of the performance of the ASTP zone electrophoresis experiment involving embryonic kidney cells is reported. The feasibility of producing standard particles for electrophoresis was also studied. This work was undertaken in response to a need for standardization of methods for producing, calibrating, and storing electrophoretic particle standards which could be employed in performance tests of various types of electrophoresis equipment. Promising procedures were tested for their suitability in the production of standard test particles from red blood cells.

  4. Capillary Zone Electrophoresis for the Analysis of Peptides: Fostering Students' Problem-Solving and Discovery Learning in an Undergraduate Laboratory Experiment

    ERIC Educational Resources Information Center

    Albright, Jessica C.; Beussman, Douglas J.

    2017-01-01

    Capillary electrophoresis is an important analytical separation method used to study a wide variety of samples, including those of biological origin. Capillary electrophoresis may be covered in the classroom, especially in advanced analytical courses, and while many students are exposed to gel electrophoresis in biology or biochemistry…

  5. Determination of benzimidazoles in meat samples by capillary zone electrophoresis tandem mass spectrometry following dispersive liquid-liquid microextraction.

    PubMed

    Tejada-Casado, Carmen; Moreno-González, David; Lara, Francisco J; García-Campaña, Ana M; Del Olmo-Iruela, Monsalud

    2017-03-24

    A novel method based on capillary zone electrophoresis-tandem mass spectrometry has been proposed and validated for the identification and simultaneous quantification of twelve benzimidazoles in meat samples. Electrophoretic separation was carried out using 500mM formic acid (pH 2.2) as background electrolyte and applying a voltage of 25kV at 25°C. In order to improve the sensitivity, stacking mode injection was applied, using as injection solvent a mixture of 30:70 acetonitrile/water at 50mbar for 75s. Sensitivity enhancement factors from 74 to 317 were obtained under these conditions. Detection using an ion trap as analyzer, operating in multiple reactions monitoring mode was employed. The main MS/MS parameters as well as the composition of the sheath liquid and other electrospray variables were optimized in order to obtain the highest sensitivity and precision in conjunction with an unequivocal identification. The method was applied to poultry and pork muscle samples. The deproteinization of samples and extraction of benzimidazoles was carried out with acetonitrile. MgSO 4 and NaCl were added as salting-out agents. Subsequently, dispersive liquid-liquid microextraction was applied as clean up procedure. The organic layer (acetonitrile, used as dispersant) containing the benzimidazoles was mixed with the extractant (chloroform) and both were injected in water, producing a cloudy solution. Recoveries for fortified samples were higher than 70%, with relative standard deviations lower than 16% were obtained in all cases. The limits of detection were below 3μgkg -1 , demonstrating the applicability of this fast, simple, and environmentally friendly method. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Effect of ionic liquids on the interaction between liposomes and common wastewater pollutants investigated by capillary electrophoresis.

    PubMed

    Ruokonen, Suvi-Katriina; Duša, Filip; Lokajová, Jana; Kilpeläinen, Ilkka; King, Alistair W T; Wiedmer, Susanne K

    2015-07-31

    The effect of three phosphonium and imidazolium ionic liquids (ILs) on the interaction between liposomes and common pharmaceuticals found in wastewaters was studied. The liposomes comprised zwitterionic phosphatidyl choline and negatively charged phosphatidyl glycerol. A set of common cationic, anionic, and neutral compounds with varying chemical composition and unique structures were included in the study. The electrophoretic mobilities of the analytes were determined using conventional capillary electrophoresis (CE), using CE under reversed electroosmotic flow mobility conditions, and in the presence of ILs in the background electrolyte (BGE) solution by electrokinetic chromatography (EKC). In order to evaluate the impact of ILs on the interaction between the compounds and the liposomes, EKC was performed with liposome dispersions, with and without ILs. The retention factors of the compounds were calculated using BGEs including liposome dispersions with and without ILs. Two phosphonium based ILs, namely tributyl(tetradecyl)phosphonium chloride ([P14444]Cl) and octyltributylphosphonium chloride ([P8444]Cl), were chosen due to their long alkyl chains and their low aggregation concentrations. Another IL, i.e. 1-ethyl-3-methylimidazolium acetate ([emim][OAc]), was chosen based on our previous study, which suggests that it has a minimal or even nonexistent effect on liposomes at the used concentrations. The results indicate that the studied ILs have an effect on the interactions between wastewater compounds and liposomes, but the effect is highly dependent on the concentration of the IL and on the IL alkyl chain lengths. Most of the ILs hindered the interactions between the liposomes and the compounds, indicating strong interaction between ILs and liposomes. In addition, the nature of the studied compounds themselves affected the interactions. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Determination of dissociation constants of compounds with potential cognition enhancing activity by capillary zone electrophoresis.

    PubMed

    Lisková, Anna; Krivánková, Ludmila

    2005-12-01

    Accurate determination of pK(a) values is important for proper characterization of newly synthesized molecules. In this work we have used CZE for determination of pK(a) values of new compounds prepared from intermediates, 2, 3 and 4-(2-chloro-acetylamino)-phenoxyacetic acids, by substituting chloride for 2-oxo-pyrrolidine, 2-oxo-piperidine or 2-oxo-azepane. These substances are expected to have a cognition enhancing activity and free radicals scavenging effect. Measurements were performed in a polyacrylamide-coated fused-silica capillary of 0.075 mm ID using direct UV detection at 254 nm. Three electrolyte systems were used for measurements to eliminate effects of potential interactions between tested compounds and components of the BGE. In the pH range 2.7-5.4, chloride, formate, acetate and phosphate were used as BGE co-ions, and sodium, beta-alanine and epsilon-aminocaproate as counterions. Mobility standards were measured simultaneously with the tested compounds for calculations of correct electrophoretic mobilities. Several approaches for the calculation of the pK(a) values were used. The values of pK(a) were determined by standard point-to-point calculation using Henderson-Hasselbach equation. Mobility and pH data were also evaluated by using nonlinear regression. Three parameter sigmoidal function fitted the experimental data with correlation coefficients higher than 0.99. Results from CZE measurements were compared with spectrophotometric measurements performed in sodium formate buffer solutions and evaluated at wavelength where the highest absorbance difference for varying pH was recorded. The experimental pK(a) values were compared with corresponding values calculated by the SPARC online calculator. Results of all three used methods were in good correlation.

  8. A chiral enantioseparation generic strategy for anti-Alzheimer and antifungal drugs by short end injection capillary electrophoresis using an experimental design approach.

    PubMed

    Abdel-Megied, Ahmed M; Hanafi, Rasha S; Aboul-Enein, Hassan Y

    2018-02-01

    The present study describes a generic strategy using capillary electrophoretic (CE) method for chiral enantioseparation of anti-Alzheimer drugs, namely, donepezil (DON), rivastigmine (RIV), and antifungal drugs, namely, ketoconazole (KET), Itraconazole (ITR), fluconazole (FLU), and sertaconazole (SRT) in which these drugs have different basic and acidic properties. Several modified cyclodextrins (CDs) were applied for enantioseparation of racemates such as highly sulfated α, γ CDs, hydroxyl propyl-β-CD, and Sulfobutyl ether-β-CD. The starting screening conditions consist of 50-mM phosphate-triethanolamine buffer at pH 2.5, an applied voltage of 15 kV, and a temperature of 25°C. The CE strategy implemented in the separation starts by screening prior to the optimization stage in which an experimental design is applied. The design of experiment (DOE) was based on a full factorial design of the crucial two factors (pH and %CD) at three levels, to make a total of nine (3 2 ) experiments with high, intermediate, and low values for both factors. Evaluation of the proposed strategy pointed out that best resolution was obtained at pH 2.5 for five racemates using low percentages of HS-γ-CD, while SBE-β-CD was the most successful chiral selector offering acceptable resolution for all the six racemates, with the best separation at low pH values and at higher %CD within 10-min runtime. Regression study showed that the linear model shows a significant lack of fit for all chiral selectors, anticipating that higher orders of the factors are most likely to be present in the equation with possible interactions. © 2017 Wiley Periodicals, Inc.

  9. Focused analyte spray emission apparatus and process for mass spectrometric analysis

    DOEpatents

    Roach, Patrick J [Kennewick, WA; Laskin, Julia [Richland, WA; Laskin, Alexander [Richland, WA

    2012-01-17

    An apparatus and process are disclosed that deliver an analyte deposited on a substrate to a mass spectrometer that provides for trace analysis of complex organic analytes. Analytes are probed using a small droplet of solvent that is formed at the junction between two capillaries. A supply capillary maintains the droplet of solvent on the substrate; a collection capillary collects analyte desorbed from the surface and emits analyte ions as a focused spray to the inlet of a mass spectrometer for analysis. The invention enables efficient separation of desorption and ionization events, providing enhanced control over transport and ionization of the analyte.

  10. Safety hazards in bacteriocinogenic Staphylococcus strains isolated from goat and sheep milk.

    PubMed

    Rahmdel, Samane; Hosseinzadeh, Saeid; Shekarforoush, Seyed Shahram; Torriani, Sandra; Gatto, Veronica; Pashangeh, Safoora

    2018-03-01

    In this study, 28 bacteriocinogenic Staphylococcus strains isolated from goat and sheep milk were subjected to the PCR detection of enterotoxin genes (sea-see), enterotoxin-like toxin Q gene (selq), toxic shock syndrome toxin gene (tst1), and antibiotic resistance genes. They were also evaluated for phenotypic resistance against 10 antibiotics and hemolytic activity. The tyramine and histamine production was investigated using the agar plate assay and capillary zone electrophoretic analysis (CZE). Twenty-five isolates harbored at least one enterotoxin gene. The gene sec was the most frequent (89%). The gene tst1 was found in 84% of sec-positive isolates. The occurrence of antibiotic resistance genes was in the order of blaZ/tetK (100%), mecA/ermB (86%), ermC (50%), and tetM (18%). The genes ermA, aac(6')Ie-aph(2″)Ia, vanA, and vanB were absent in all the isolates. Nineteen isolates were phenotypically susceptible to all the antibiotics. The only isolate with phenotypic resistance to penicillin G and oxacillin was S. epidermidis 4S93 which had a different SmaI-PFGE profile from those of the other S. epidermidis strains. All the S. haemolyticus and S. pseudintermedius isolates were not susceptible to trimethoprim. Twenty-five isolates showed complete or partial hemolytic activity. None of the isolates was able to decarboxylate tyrosine, while CZE analysis revealed histamine formation activity in S. haemolyticus 4S12. The occurrence of safety risks in the isolates reinforces the need for regular monitoring of food-producing animals to mitigate the risks of multidrug resistant and zoonotic pathogens. Moreover, none of the isolates fulfilled the safety criteria to be used as starter cultures or biopreservatives. Copyright © 2018. Published by Elsevier Ltd.

  11. Capillary isoelectric focusing of probiotic bacteria from cow's milk in tapered fused silica capillary with off-line matrix-assisted laser desorption/ionization time-of-flight mass spectrometry identification.

    PubMed

    Horká, Marie; Karásek, Pavel; Salplachta, Jiří; Růžička, Filip; Vykydalová, Marie; Kubesová, Anna; Dráb, Vladimír; Roth, Michal; Slais, Karel

    2013-07-25

    In this study, combination of capillary isoelectric focusing (CIEF) in tapered fused silica (FS) capillary with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is presented as an efficient approach for unambiguous identification of probiotic bacteria in real sample. For this purpose, bacteria within genus Lactobacillus were selected as model bioanalytes and cow's milk was selected as a biological sample. CIEF analysis of both the cultivated bacteria and the bacteria in the milk was optimized and isoelectric points characterizing the examined bacteria were subsequently determined independently of the bacterial sample origin. The use of tapered FS capillary significantly enhanced the separation capacity and efficiency of the CIEF analyses performed. In addition, the cell number injected into the tapered FS capillary was quantified and an excellent linearity of the calibration curves was achieved which enabled quantitative analysis of the bacteria by CIEF with UV detection. The minimum detectable number of bacterial cells was 2×10(6) mL(-1). Finally, cow's milk spiked with the selected bacterium was analyzed by CIEF in tapered FS capillary, the focused and detected bacterial cells were collected from the capillary, deposited onto the cultivation medium, and identified using MALDI-TOF MS afterward. Our results have revealed that the proposed procedure can be advantageously used for unambiguous identification of probiotic bacteria in a real sample. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Demonstrating Electrophoretic Separation in a Straight Paper Channel Delimited by a Hydrophobic Wax Barrier

    ERIC Educational Resources Information Center

    Xu, Chunxiu; Lin, Wanqi; Cai, Longfei

    2016-01-01

    A demonstration is described of electrophoretic separation of carmine and sunset yellow with a paper-based device. The channel in the paper device was fabricated by hand with a wax pen. Electrophoretic separation of carmine and sunset yellow was achieved within a few minutes by applying potential on the channel using a simple and inexpensive power…

  13. Electrophoretic mobilities of erythrocytes in various buffers

    NASA Technical Reports Server (NTRS)

    Plank, L. D.; Kunze, M. E.; Todd, P. W.

    1985-01-01

    The calibration of space flight equipment depends on a source of standard test particles, this test particle of choice is the fixed erythrocyte. Erythrocytes from different species have different electrophoretic mobilities. Electrophoretic mobility depends upon zeta potential, which, in turn depends upon ionic strength. Zeta potential decreases with increasing ionic strength, so cells have high electrophoretic mobility in space electrophoresis buffers than in typical physiological buffers. The electrophoretic mobilities of fixed human, rat, and rabbit erythrocytes in 0.145 M salt and buffers of varying ionic strength, temperature, and composition, to assess the effects of some of the unique combinations used in space buffers were characterized. Several effects were assessed: glycerol or DMSO (dimethylsulfoxide) were considered for use as cryoprotectants. The effect of these substances on erythrocyte electrophoretic mobility was examined. The choice of buffer depended upon cell mobility. Primary experiments with kidney cells established the choice of buffer and cryoprotectant. A nonstandard temperature of EPM in the suitable buffer was determined. A loss of ionic strength control occurs in the course of preparing columns for flight, the effects of small increases in ionic strength over the expected low values need to be evaluated.

  14. Continuous particle separation using pressure-driven flow-induced miniaturizing free-flow electrophoresis (PDF-induced μ-FFE).

    PubMed

    Jeon, Hyungkook; Kim, Youngkyu; Lim, Geunbae

    2016-01-28

    In this paper, we introduce pressure-driven flow-induced miniaturizing free-flow electrophoresis (PDF-induced μ-FFE), a novel continuous separation method. In our separation system, the external flow and electric field are applied to particles, such that particle movement is affected by pressure-driven flow, electroosmosis, and electrophoresis. We then analyzed the hydrodynamic drag force and electrophoretic force applied to the particles in opposite directions. Based on this analysis, micro- and nano-sized particles were separated according to their electrophoretic mobilities with high separation efficiency. Because the separation can be achieved in a simple T-shaped microchannel, without the use of internal electrodes, it offers the advantages of low-cost, simple device fabrication and bubble-free operation, compared with conventional μ-FFE methods. Therefore, we expect the proposed separation method to have a wide range of filtering/separation applications in biochemical analysis.

  15. Electrophoretic Deposition of Hydroxyapatite Film Containing Re-Doped MoS2 Nanoparticles

    PubMed Central

    Shalom, Hila; Feldman, Yishay; Rosentsveig, Rita; Pinkas, Iddo; Kaplan-Ashiri, Ifat; Moshkovich, Alexey; Perfilyev, Vladislav; Rapoport, Lev

    2018-01-01

    Films combining hydroxyapatite (HA) with minute amounts (ca. 1 weight %) of (rhenium doped) fullerene-like MoS2 (IF) nanoparticles were deposited onto porous titanium substrate through electrophoretic process (EPD). The films were analyzed by scanning electron microscopy (SEM), X-ray diffraction and Raman spectroscopy. The SEM analysis showed relatively uniform coatings of the HA + IF on the titanium substrate. Chemical composition analysis using energy dispersive X-ray spectroscopy (EDS) of the coatings revealed the presence of calcium phosphate minerals like hydroxyapatite, as a majority phase. Tribological tests were undertaken showing that the IF nanoparticles endow the HA film very low friction and wear characteristics. Such films could be of interest for various medical technologies. Means for improving the adhesion of the film to the underlying substrate and its fracture toughness, without compromising its biocompatibility are discussed at the end. PMID:29495394

  16. Continuous particle separation using pressure-driven flow-induced miniaturizing free-flow electrophoresis (PDF-induced μ-FFE)

    PubMed Central

    Jeon, Hyungkook; Kim, Youngkyu; Lim, Geunbae

    2016-01-01

    In this paper, we introduce pressure-driven flow-induced miniaturizing free-flow electrophoresis (PDF-induced μ-FFE), a novel continuous separation method. In our separation system, the external flow and electric field are applied to particles, such that particle movement is affected by pressure-driven flow, electroosmosis, and electrophoresis. We then analyzed the hydrodynamic drag force and electrophoretic force applied to the particles in opposite directions. Based on this analysis, micro- and nano-sized particles were separated according to their electrophoretic mobilities with high separation efficiency. Because the separation can be achieved in a simple T-shaped microchannel, without the use of internal electrodes, it offers the advantages of low-cost, simple device fabrication and bubble-free operation, compared with conventional μ-FFE methods. Therefore, we expect the proposed separation method to have a wide range of filtering/separation applications in biochemical analysis. PMID:26819221

  17. A replaceable microreactor for on-line protein digestion in a two-dimensional capillary electrophoresis system with tandem mass spectrometry detection

    PubMed Central

    Li, Yihan; Wojcik, Roza; Dovichi, Norman J.

    2010-01-01

    We describe a two-dimensional capillary electrophoresis system that incorporates a replaceable enzymatic microreactor for on-line protein digestion. In this system, trypsin is immobilized on magnetic beads. At the start of each experiment, old beads are flushed to waste and replaced with a fresh plug of beads, which is captured by a pair of magnets at the distal tip of the first capillary. For analysis, proteins are separated in the first capillary. A fraction is then parked in the reactor to create peptides. Digested peptides are periodically transferred to the second capillary for separation; a fresh protein fraction is simultaneously moved to the reactor for digestion. An electrospray interface is used to introduce peptides into a mass spectrometer for analysis. This procedure is repeated for several dozen fractions under computer control. The system was demonstrated by the separation and digestion of insulin chain b oxidized and β-casein as model proteins. PMID:21030030

  18. R-134a qualification -- industry refrigerator capillary data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeVos, R.

    1997-12-31

    With the phaseout of R-12, the use of R-134a and polyolester (POE) oil became the preferred refrigerant/oil combination for the refrigerator appliance industry. Reliability data for this refrigerant/oil combination were minimal, and initial testing showed a propensity for the capillary tubes to clog with a variety of contaminants. A test was designed by an industry group to accelerate the process of contamination and capillary plugging. This paper presents capillary tube stress test data that were developed for this group by its member companies. This study investigated the relationship between capillary tube restriction levels and variables including compressor type, oil type,more » chlorine level, and moisture level. Analysis of the contaminants included a visual description, infrared spectroscopy, scanning electron microscope examination, and measurements of total chlorine content and noncondensable gas content of the refrigerant. Oil samples were measured for moisture level, dissolved iron, and total acid, and an infrared spectral analysis was performed.« less

  19. Capillary Flow in Containers of Polygonal Section: Theory and Experiment

    NASA Technical Reports Server (NTRS)

    Weislogel, Mark M.; Rame, Enrique (Technical Monitor)

    2001-01-01

    An improved understanding of the large-length-scale capillary flows arising in a low-gravity environment is critical to that engineering community concerned with the design and analysis of spacecraft fluids management systems. Because a significant portion of liquid behavior in spacecraft is capillary dominated it is natural to consider designs that best exploit the spontaneous character of such flows. In the present work, a recently verified asymptotic analysis is extended to approximate spontaneous capillary flows in a large class of cylindrical containers of irregular polygonal section experiencing a step reduction in gravitational acceleration. Drop tower tests are conducted using partially-filled irregular triangular containers for comparison with the theoretical predictions. The degree to which the experimental data agree with the theory is a testament to the robustness of the basic analytical assumption of predominantly parallel flow. As a result, the closed form analytical expressions presented serve as simple, accurate tools for predicting bulk flow characteristics essential to practical low-g system design and analysis. Equations for predicting corner wetting rates, total container flow rates, and transient surfaces shapes are provided that are relevant also to terrestrial applications such as capillary flow in porous media.

  20. A Theoretical Analysis of the Influence of Electroosmosis on the Effective Ionic Mobility in Capillary Zone Electrophoresis

    ERIC Educational Resources Information Center

    Hijnen, Hens

    2009-01-01

    A theoretical description of the influence of electroosmosis on the effective mobility of simple ions in capillary zone electrophoresis is presented. The mathematical equations derived from the space-charge model contain the pK[subscript a] value and the density of the weak acid surface groups as parameters characterizing the capillary. It is…

  1. Analysis of HbA1c on an automated multicapillary zone electrophoresis system.

    PubMed

    Rollborn, Niclas; Åkerfeldt, Torbjörn; Nordin, Gunnar; Xu, Xiao Yan; Mandic-Havelka, Aleksandra; Hansson, Lars-Olof; Larsson, Anders

    2017-02-01

    Hemoglobin A1c (HbA1c) is a frequently requested laboratory test and there is thus a need for high throughput instruments for this assay. We evaluated a new automated multicapillary zone electrophoresis instrument (Capillarys 3 Tera, Sebia, Lisses, France) for analysis of HbA1c in venous samples. Routine requested HbA1c samples were analyzed immunologically on a Roche c6000 instrument (n = 142) and then with the Capillarys 3 Tera instrument. The Capillarys 3 Tera instrument performed approximately 70 HbA1c tests/hour. There was a strong linear correlation between Capillarys 3 Tera and Roche Tina-Quant HbA1c Gen 3 assay (y = 1.003x - 0.3246 R 2  = .996). The total CV for the 12 capillaries varied between 0.8 and 2.2% and there was a good agreement between duplicate samples (R 2  = .997). In conclusion, the Capillarys 3 Tera instrument has a high assay capacity for HbA1c. It has a good precision and agreement with the Roche Tina-Quant HbA1c method and is well suited for high volume testing of HbA1c.

  2. Miniaturized flow injection analysis system

    DOEpatents

    Folta, James A.

    1997-01-01

    A chemical analysis technique known as flow injection analysis, wherein small quantities of chemical reagents and sample are intermixed and reacted within a capillary flow system and the reaction products are detected optically, electrochemically, or by other means. A highly miniaturized version of a flow injection analysis system has been fabricated utilizing microfabrication techniques common to the microelectronics industry. The microflow system uses flow capillaries formed by etching microchannels in a silicon or glass wafer followed by bonding to another wafer, commercially available microvalves bonded directly to the microflow channels, and an optical absorption detector cell formed near the capillary outlet, with light being both delivered and collected with fiber optics. The microflow system is designed mainly for analysis of liquids and currently measures 38.times.25.times.3 mm, but can be designed for gas analysis and be substantially smaller in construction.

  3. Integrated multiplexed capillary electrophoresis system

    DOEpatents

    Yeung, Edward S.; Tan, Hongdong

    2002-05-14

    The present invention provides an integrated multiplexed capillary electrophoresis system for the analysis of sample analytes. The system integrates and automates multiple components, such as chromatographic columns and separation capillaries, and further provides a detector for the detection of analytes eluting from the separation capillaries. The system employs multiplexed freeze/thaw valves to manage fluid flow and sample movement. The system is computer controlled and is capable of processing samples through reaction, purification, denaturation, pre-concentration, injection, separation and detection in parallel fashion. Methods employing the system of the invention are also provided.

  4. Transformation of Sordaria macrospora to hygromycin B resistance: characterization of transformants by electrophoretic karyotyping and tetrad analysis.

    PubMed

    Walz, M; Kück, U

    1995-12-01

    The ascomycete Sordaria macrospora was transformed using different plasmid molecules containing the bacterial hygromycin B resistance gene (hph) under the control of different expression signals. The highest transformation frequency was obtained with vector pMW1. On this plasmid molecule, expression of the hph gene is directed by the upstream region of the isopenicillin N synthetase gene (pcbC) from the deuteromycete Acremonium chrysogenum. Southern analysis suggests that the vector copies are integrated as tandem repeats into the S. macrospora chromosomes and that duplicated sequences are most probably not inactivated by methylation during meiosis. Furthermore, the hygromycin B resistance (hygR) is not correlated with the number of integrated vector molecules. Electrophoretic karyotyping was used to further characterize S. macrospora transformants. Five chromosomal bands were separated by pulsed-field gel electrophoresis (PFGE) representing seven chromosomes with a total genome size of 39.5Mb. Hybridization analysis revealed ectopic integration of vector DNA into different chromosomes. In a few transformants, major rearrangements were detected. Transformants were sexually propagated to analyze the fate of the heterologous vector DNA. Although the hygR phenotype is stably maintained during mitosis, about a third of all lines tested showed loss of the resistance marker gene after meiosis. However, as was concluded from electrophoretic karyotyping, the resistant spores showed a Mendelian segregation of the integrated vector molecules in at least three consecutive generations. Our data indicate that heterologous marker genes can be used for transformation tagging, or the molecular mapping of chromosomal loci in S. macrospora.

  5. Accuracy of capillary blood 3-β-hydroxybutyrate determination for the detection and treatment of canine diabetic ketoacidosis.

    PubMed

    Bresciani, Francesca; Pietra, Marco; Corradini, Sara; Giunti, Massimo; Fracassi, Federico

    2014-01-01

    In human medicine, diagnosis of diabetic ketoacidosis (DKA) is usually based on measurement of capillary 3-β-hydroxybutyrate (3-HB) with a hand held ketone sensor. This study was conducted to determine if measurement of capillary 3-HB could be useful for the diagnosis and monitoring of canine DKA. Fifteen dogs with diabetic ketosis and 10 with DKA were evaluated. Paired measurements of 3-HB of capillary and venous blood samples were analysed by the electrochemical sensor and reference method. Use of capillary 3-HB measurement during DKA management was then evaluated through simultaneous measurements of capillary 3-HB, urinary AcAc and venous blood gas analysis. Good agreement between capillary and venous 3-HB measurement was detected by the electrochemical sensor and reference method. Monitoring treatment of DKA revealed a significant correlation between capillary 3-HB and acidosis markers, while no significant correlation was observed between AcAc and acidosis markers. A cut-off value of capillary blood 3-HB > 3.8 mmol/L for diagnosis of DKA resulted in 70% and 92% sensitivity and specificity. The electrochemical sensor accurately measures 3-HB concentration in both capillary and venous blood samples, is accurate in diagnosing canine DKA, and appears to reflect the patient's metabolic status during DKA treatment.

  6. A Laboratory Exercise Illustrating the Sensitivity and Specificity of Western Blot Analysis

    ERIC Educational Resources Information Center

    Chang, Ming-Mei; Lovett, Janice

    2011-01-01

    Western blot analysis, commonly known as "Western blotting," is a standard tool in every laboratory where proteins are analyzed. It involves the separation of polypeptides in polyacrylamide gels followed by the electrophoretic transfer of the separated polypeptides onto a nitrocellulose or polyvinylidene fluoride membrane. A replica of the…

  7. Quantitative analysis of nailfold capillary morphology in patients with fibromyalgia

    PubMed Central

    Choi, Dug-Hyun

    2015-01-01

    Background/Aims Nailfold capillaroscopy (NFC) has been used to examine morphological and functional microcirculation changes in connective tissue diseases. It has been demonstrated that NFC patterns reflect abnormal microvascular dynamics, which may play a role in fibromyalgia (FM) syndrome. The aim of this study was to determine NFC patterns in FM, and their association with clinical features of FM. Methods A total of 67 patients with FM, and 30 age- and sex-matched healthy controls, were included. Nailfold capillary patterns were quantitatively analyzed using computerized NFC. The parameters of interest were as follows: number of capillaries within the central 3 mm, deletion score, apical limb width, capillary width, and capillary dimension. Capillary dimension was determined by calculating the number of capillaries using the Adobe Photoshop version 7.0. Results FM patients had a lower number of capillaries and higher deletion scores on NFC compared to healthy controls (17.3 ± 1.7 vs. 21.8 ± 2.9, p < 0.05; 2.2 ± 0.9 vs. 0.7 ± 0.6, p < 0.05, respectively). Both apical limb width (µm) and capillary width (µm) were significantly decreased in FM patients (1.1 ± 0.2 vs. 3.7 ± 0.6; 5.4 ± 0.5 vs. 7.5 ± 1.4, respectively), indicating that FM patients have abnormally decreased digital capillary diameter and density. Interestingly, there was no difference in capillary dimension between the two groups, suggesting that the length or tortuosity of capillaries in FM patients is increased to compensate for diminished microcirculation. Conclusions FM patients had altered capillary density and diameter in the digits. Diminished microcirculation on NFC may alter capillary density and increase tortuosity. PMID:26161020

  8. How many taxa can be recognized within the complex Tillandsia capillaris (Bromeliaceae, Tillandsioideae)? Analysis of the available classifications using a multivariate approach.

    PubMed

    Castello, Lucía V; Galetto, Leonardo

    2013-01-01

    Tillandsia capillaris Ruiz & Pav., which belongs to the subgenus Diaphoranthema is distributed in Ecuador, Peru, Bolivia, northern and central Argentina, and Chile, and includes forms that are difficult to circumscribe, thus considered to form a complex. The entities of this complex are predominantly small-sized epiphytes, adapted to xeric environments. The most widely used classification defines 5 forms for this complex based on few morphological reproductive traits: Tillandsia capillaris Ruiz & Pav. f. capillaris, Tillandsia capillaris f. incana (Mez) L.B. Sm., Tillandsia capillaris f. cordobensis (Hieron.) L.B. Sm., Tillandsia capillaris f. hieronymi (Mez) L.B. Sm. and Tillandsia capillaris f. virescens (Ruiz & Pav.) L.B. Sm. In this study, 35 floral and vegetative characters were analyzed with a multivariate approach in order to assess and discuss different proposals for classification of the Tillandsia capillaris complex, which presents morphotypes that co-occur in central and northern Argentina. To accomplish this, data of quantitative and categorical morphological characters of flowers and leaves were collected from herbarium specimens and field collections and were analyzed with statistical multivariate techniques. The results suggest that the last classification for the complex seems more comprehensive and three taxa were delimited: Tillandsia capillaris (=Tillandsia capillaris f. incana-hieronymi), Tillandsia virescens s. str. (=Tillandsia capillaris f. cordobensis) and Tillandsia virescens s. l. (=Tillandsia capillaris f. virescens). While Tillandsia capillaris and Tillandsia virescens s. str. co-occur, Tillandsia virescens s. l. is restricted to altitudes above 2000 m in Argentina. Characters previously used for taxa delimitation showed continuous variation and therefore were not useful. New diagnostic characters are proposed and a key is provided for delimiting these three taxa within the complex.

  9. How many taxa can be recognized within the complex Tillandsia capillaris (Bromeliaceae, Tillandsioideae)? Analysis of the available classifications using a multivariate approach

    PubMed Central

    Castello, Lucía V.; Galetto, Leonardo

    2013-01-01

    Abstract Tillandsia capillaris Ruiz & Pav., which belongs to the subgenus Diaphoranthema is distributed in Ecuador, Peru, Bolivia, northern and central Argentina, and Chile, and includes forms that are difficult to circumscribe, thus considered to form a complex. The entities of this complex are predominantly small-sized epiphytes, adapted to xeric environments. The most widely used classification defines 5 forms for this complex based on few morphological reproductive traits: Tillandsia capillaris Ruiz & Pav. f. capillaris, Tillandsia capillaris f. incana (Mez) L.B. Sm., Tillandsia capillaris f. cordobensis (Hieron.) L.B. Sm., Tillandsia capillaris f. hieronymi (Mez) L.B. Sm. and Tillandsia capillaris f. virescens (Ruiz & Pav.) L.B. Sm. In this study, 35 floral and vegetative characters were analyzed with a multivariate approach in order to assess and discuss different proposals for classification of the Tillandsia capillaris complex, which presents morphotypes that co-occur in central and northern Argentina. To accomplish this, data of quantitative and categorical morphological characters of flowers and leaves were collected from herbarium specimens and field collections and were analyzed with statistical multivariate techniques. The results suggest that the last classification for the complex seems more comprehensive and three taxa were delimited: Tillandsia capillaris (=Tillandsia capillaris f. incana-hieronymi), Tillandsia virescens s. str. (=Tillandsia capillaris f. cordobensis) and Tillandsia virescens s. l. (=Tillandsia capillaris f. virescens). While Tillandsia capillaris and Tillandsia virescens s. str. co-occur, Tillandsia virescens s. l. is restricted to altitudes above 2000 m in Argentina. Characters previously used for taxa delimitation showed continuous variation and therefore were not useful. New diagnostic characters are proposed and a key is provided for delimiting these three taxa within the complex. PMID:23805053

  10. FAST TRACK COMMUNICATION: High material efficiency found in electrophoretic deposition of conjugated polymer

    NASA Astrophysics Data System (ADS)

    Tada, Kazuya; Onoda, Mitsuyoshi

    2009-09-01

    The material efficiency of electrophoretic deposition of a fluorene-based conjugated polymer, poly[(9,9-dioctyl-2,7-divinylenefluorenylene)-alt-{2-methoxy-5-(2-ethylhexyloxy)-1,4-phenylene}] (PDOF-MEHPV), from suspensions with a mixture of acetonitrile and toluene as dispersant is studied. It has been found that the recovery rate of the electrophoretic deposition from a suspension containing 90% of the poor solvent acetonitrile reaches 98%. Although the recovery rate decreases with decreasing acetonitrile content, almost 70% of the polymer can be deposited on the substrates from the suspension containing equivalent volumes of the good and poor solvents by electrophoretic deposition, from which smooth and transparent films suitable for electronic devices are obtained.

  11. Electrophoretic interactions and aggregation of colloidal biological particles

    NASA Technical Reports Server (NTRS)

    Davis, Robert H.; Nichols, Scott C.; Loewenberg, Michael; Todd, Paul

    1994-01-01

    The separation of cells or particles from solution has traditionally been accomplished with centrifuges or by sedimentation; however, many particles have specific densities close to unity, making buoyancy-driven motion slow or negligible, but most cells and particles carry surface charges, making them ideal for electrophoretic separation. Both buoyancy-driven and electrophoretic separation may be influenced by hydrodynamic interactions and aggregation of neighboring particles. Aggregation by electrophoresis was analyzed for two non-Brownian particles with different zeta potentials and thin double layers migrating through a viscous fluid. The results indicate that the initial rate of electrophoretically-driven aggregation may exceed that of buoyancy-driven aggregation, even under conditions in which buoyancy-driven relative motion of noninteracting particles is dominant.

  12. Determining bruise etiology in muscle tissue using finite element analysis.

    PubMed

    Tang, Kevin; Sharpe, Wyatt; Schulz, Alexandra; Tam, Edric; Grosse, Ian; Tis, John; Cullinane, Dennis

    2014-03-01

    Bruising, the result of capillary failure, is a common physical exam finding due to blunt trauma and, depending on location and severity, a potential indicator of abuse. Despite its clinical relevance, few studies have investigated the etiology of capillary failure. The goal of this study was to determine whether capillaries primarily fail under shear stress or hydraulic-induced tensile stress. An arteriole bifurcating into four capillaries was modeled using ANSYS 14.0 (®) . The capillaries were embedded in muscle tissue and a pressure of 20.4 kPa was applied. Any tensile stress exceeding 8.4 × 10(4)  Pa was considered failure. Results showed that failure occurred directly under the impact zone and where capillaries bifurcated, rather than along the line of greatest shear stress, indicating that internal tensile stress is likely the primary mode of capillary failure in bruising. These results are supported by the concept that bruising can occur via blunt trauma in which no shearing lacerations occur. © 2013 American Academy of Forensic Sciences.

  13. Hemoglobin measured by Hemocue and a reference method in venous and capillary blood: a validation study.

    PubMed

    Neufeld, Lynnette; García-Guerra, Armando; Sánchez-Francia, Domingo; Newton-Sánchez, Oscar; Ramírez-Villalobos, María Dolores; Rivera-Dommarco, Juan

    2002-01-01

    To assess the comparability of hemoglobin concentration (Hb) in venous and capillary blood measured by Hemocue and an automated spectrophotometer (Celldyn) and to document the influence of type of blood (capillary or venous) and analysis method on anemia prevalence estimates. Between February and May 2000, capillary and venous samples were collected from 72 adults and children at Hospital del Niño Morelense (Morelos State Children's Hospital) in Cuernavaca, Morelos, Mexico, and assessed for Hb using the Hemocue and Celldyn methods. Estimated Hb levels were compared using the concordance correlation coefficient and Student's t test for paired data. The sensitivity and specificity for anemia diagnosis were estimated and compared between type of blood and method of assessment. Capillary blood had higher Hb (+0.5 g/dl) than venous blood in adults and children, as did samples assessed by Celldyn compared to Hemocue (+0.3 g/dl). Specificity to detect anemia was adequate (> 0.90) but sensitivity was low for capillary blood assessed by Hemocue (< 0.80). The difference in Hb between venous and capillary blood is likely related to biological variability. Hemoglobin concentration in capillary blood assessed by Hemocue provides an adequate estimation of population anemia prevalence but may result in excess false negative diagnoses among individuals. The results of this study stress the importance of sample collection technique, particularly for children. Method of analysis and sampling site need to be taken into consideration in field studies. The English version of this paper is available too at: http://www.insp.mx/salud/index.html.

  14. A coupling modulation model of capillary waves from gravity waves: Theoretical analysis and experimental validation

    NASA Astrophysics Data System (ADS)

    Chen, Pengzhen; Wang, Xiaoqing; Liu, Li; Chong, Jinsong

    2016-06-01

    According to Bragg theory, capillary waves are the predominant scatterers of high-frequency band (such as Ka-band) microwave radiation from the surface of the ocean. Therefore, understanding the modulation mechanism of capillary waves is an important foundation for interpreting high-frequency microwave remote sensing images of the surface of the sea. In our experiments, we discovered that modulations of capillary waves are significantly larger than the values predicted by the classical theory. Further, analysis shows that the difference in restoring force results in an inflection point while the phase velocity changes from gravity waves region to capillary waves region, and this results in the capillary waves being able to resonate with gravity waves when the phase velocity of the gravity waves is equal to the group velocity of the capillary waves. Consequently, we propose a coupling modulation model in which the current modulates the capillary wave indirectly by modulating the resonant gravity waves, and the modulation of the former is approximated by that of the latter. This model very effectively explains the results discovered in our experiments. Further, based on Bragg scattering theory and this coupling modulation model, we simulate the modulation of normalized radar cross section (NRCS) of typical internal waves and show that the high-frequency bands are superior to the low-frequency bands because of their greater modulation of NRCS and better radiometric resolution. This result provides new support for choice of radar band for observation of wave-current modulation oceanic phenomena such as internal waves, fronts, and shears.

  15. Effect of dispersion forces on the capillary-wave fluctuations of liquid surfaces.

    PubMed

    Chacón, Enrique; Fernández, Eva M; Tarazona, Pedro

    2014-04-01

    We present molecular dynamics evidence for the nonanalytic effects of the long-range dispersion forces on the capillary waves fluctuations of a Lennard-Jones liquid surface. The results of the intrinsic sampling method, for the analysis of the instantaneous interfacial shape, are obtained in large systems for several cut-off distances of the potential tail, and they show good agreement with the theoretical prediction by Napiórkowski and Dietrich, based on a density functional analysis. The enhancement of the capillary waves is quantified to be within 1% for a simple liquid near its triple point.

  16. Electrophoretic mobilities of cultured human embryonic kidney cells in various buffers

    NASA Technical Reports Server (NTRS)

    1985-01-01

    Data on the electrophoretic mobility distributions of cells in the new D-1 buffer and the interlaboratory standardization of urokinase assay methods are presented. A table of cell strains and recent data on cell dispersal methods are also included. It was decided that glycerol in A-1 electrophoretic mobility data on cultured human embryonic kidney cells subjected to electrophoresis in this buffer. The buffer composition is presented.

  17. High-resolution slab gel isoelectric focusing: methods for quantitative electrophoretic transfer and immunodetection of proteins as applied to the study of the multiple isoelectric forms of ornithine decarboxylase.

    PubMed

    Reddy, S G; Cochran, B J; Worth, L L; Knutson, V P; Haddox, M K

    1994-04-01

    A high-resolution isoelectric focusing vertical slab gel method which can resolve proteins which differ by a single charge was developed and this method was applied to the study of the multiple isoelectric forms of ornithine decarboxylase. Separation of proteins at this high level of resolution was achieved by increasing the ampholyte concentration in the gels to 6%. Various lots of ampholytes, from the same or different commercial sources, differed significantly in their protein binding capacity. Ampholytes bound to proteins interfered both with the electrophoretic transfer of proteins from the gel to immunoblotting membranes and with the ability of antibodies to interact with proteins on the immunoblotting membranes. Increasing the amount of protein loaded into a gel lane also decreased the efficiency of the electrophoretic transfer and immunodetection. To overcome these problems, both gel washing and gel electrophoretic transfer protocols for disrupting the ampholyte-protein binding and enabling a quantitative electrophoretic transfer of proteins were developed. Two gel washing procedures, with either thiocyanate or borate buffers, and a two-step electrophoretic transfer method are described. The choice of which method to use to optimally disrupt the ampholyte-protein binding was found to vary with each lot of ampholytes employed.

  18. Investigation of the free flow electrophoretic process. Volume 2: Technical analysis

    NASA Technical Reports Server (NTRS)

    Weiss, R. A.; Lanham, J. W.; Richman, D. W.; Walker, C. D.

    1979-01-01

    The effect of gravity on the free flow electrophoretic process was investigated. The demonstrated effects were then compared with predictions made by mathematical models. Results show that the carrier buffer flow was affected by gravity induced thermal convection and that the movement of the separating particle streams was affected by gravity induced buoyant forces. It was determined that if gravity induced buoyant forces were included in the mathematical models, then effective predictions of electrophoresis chamber separation performance were possible. The results of tests performed using various methods of electrophoresis using supportive media show that the mobility and the ability to separate were essentially independent of concentration, providing promise of being able to perform electrophoresis with higher inlet concentrations in space.

  19. Mechanism of acute depletion of plasma fibronectin following thermal injury in rats. Appearance of a gelatinlike ligand in plasma.

    PubMed Central

    Deno, D C; McCafferty, M H; Saba, T M; Blumenstock, F A

    1984-01-01

    Plasma fibronectin was depleted within 15 min following sublethal burn, followed by partial recovery at 8 h and complete restoration by 24 h in anesthetized rats. Radiolabeled 75Se-plasma fibronectin, injected intravenously before burn, was rapidly sequestered in burn skin as well as the liver. Fibronectin levels at 2 h postburn as detected by immunoassay vs. 75Se-plasma fibronectin indicated that more fibronectin was in the plasma than detected by electroimmunoassay. Crossed immunoelectrophoretic analysis of fibronectin in early postburn plasma demonstrated a reduced electrophoretic mobility of the fibronectin antigen. Addition of heparin or fibrin, both of which have affinity for fibronectin, to normal plasma was unable to reproduce this altered fibronectin electrophoretic pattern. In contrast, addition of gelatin or native collagen to normal plasma reproduced the abnormal electrophoretic pattern of fibronectin seen in burn plasma. Extracts of burned skin, but not extracts of normal skin, when added to normal plasma, elicited a similar altered electrophoretic pattern for fibronectin. By gel filtration, fibronectin in burn plasma had an apparent molecular weight approximately 40% greater than that observed in normal plasma. These data suggest the release into the blood of a gelatinlike ligand from burned skin, which complexes with plasma fibronectin. Thus, fibronectin deficiency acutely postburn appears mediated by (a) its accumulation at the site of burn injury; (b) its removal from the circulation by the liver; and (c) its presence in the plasma in a form that is less detectable by immunoassay. Images PMID:6690478

  20. Miniaturized flow injection analysis system

    DOEpatents

    Folta, J.A.

    1997-07-01

    A chemical analysis technique known as flow injection analysis is described, wherein small quantities of chemical reagents and sample are intermixed and reacted within a capillary flow system and the reaction products are detected optically, electrochemically, or by other means. A highly miniaturized version of a flow injection analysis system has been fabricated utilizing microfabrication techniques common to the microelectronics industry. The microflow system uses flow capillaries formed by etching microchannels in a silicon or glass wafer followed by bonding to another wafer, commercially available microvalves bonded directly to the microflow channels, and an optical absorption detector cell formed near the capillary outlet, with light being both delivered and collected with fiber optics. The microflow system is designed mainly for analysis of liquids and currently measures 38{times}25{times}3 mm, but can be designed for gas analysis and be substantially smaller in construction. 9 figs.

  1. Electrophoretic Detection and Confocal Microscopic Imaging of Tyrosine Nitrated Proteins in Plant Tissue.

    PubMed

    Arora, Dhara; Singh, Neha; Bhatla, Satish C

    2018-01-01

    Tyrosine nitrated proteins can be detected in plant cells electrophoretically and their distribution can be monitored by confocal laser scanning microscopy (CLSM) imaging. One-dimensional polyacrylamide gel electrophoresis (1D PAGE) followed by Western blotting using polyclonal antibody against 3-nitrotyrosine residues enables detection of tyrosine nitrated proteins in plant cells. Here we describe detection of tyrosine nitrated proteins in the homogenates derived from sunflower (Helianthus annuus L.) seedling cotyledons. Total soluble proteins obtained from tissue homogenates are resolved using vertical gel electrophoresis followed by their electrophoretic transfer on to a microporous membrane support for immunodetection. Spatial distribution of tyrosine nitrated proteins can be visualized using an antibody against 3-nitrotyrosine residues. Immunofluorescent localization is performed by cutting 7 μm thick wax sections of tissue followed by incubation in primary anti-nitrotyrosine antibody (dilution 1:200) and secondary Cy-3 labeled anti-rabbit IgG antibody (dilution 1:1500). Confocal laser scanning microscopy analysis is undertaken using argon lasers (ex: 530-550 nm and em: 570 nm) at pinhole 1. Modulation in the abundance and spatial localization of tyrosine nitrated proteins in plant tissues can be monitored using these techniques.

  2. [Electrophoretic forms of glucose-6-phosphate dehydrogenase, acid phosphatase and esterase in Amoeba species amoebas].

    PubMed

    Sopina, V A

    2000-01-01

    Glucose-6-phosphate dehydrogenase (G6PD), acid phosphatase and esterases in free-living amoebae of 7 Amoeba species were investigated with the use of disc-electrophoresis in polyacrylamide gel. The evidence provided is suggestive that the electrophoretic isoenzyme patterns of acid phosphatase and esterases (and G6PD in some cases), in addition to a few morphological characters, can serve as a taxonomic criterion for species identification within this genus, as well as for revealing erroneously classified species and strains. It is suggested that A. indica is an independent species whose preliminary diagnosis has been given in this paper. It is concluded that A. discoides and A. lescherae are strains of A. proteus, rather than two independent species. A and As-102 amoebian strains, kept in the collection of protozoan strains and species of the Institute of Cytology RAS and referred to as strains of A. proteus, belong in reality to another Amoeba species and even to another genus within the family Amoebidae. This conclusion has been documented by results of our analysis of electrophoretic patterns of acid phosphatase and esterases in these strains.

  3. Electrophoretic deposition of multi-walled carbon nanotube on a stainless steel electrode for use in sediment microbial fuel cells.

    PubMed

    Song, Tian-Shun; Peng-Xiao; Wu, Xia-Yuan; Zhou, Charles C

    2013-07-01

    Sediment microbial fuel cells (SMFCs) could be used as power sources and one type of new technology for the removal of organic matters in sediments. In order to improve electrode materials and enhance their effect on the performance, we deposited multi-walled carbon nanotube (MWNT) on stainless steel net (SSN). Electrophoretic deposition technique as a method with low cost, process simplicity, and thickness control was used for this electrode modification and produced this novel SSN-MWNT electrode. The performances of SMFCs with SSN-MWNT as electrode were investigated. The results showed that the maximum power density of SMFC with SSN-MWNT cathode was 31.6 mW m(-2), which was 3.2 times that of SMFC with an uncoated stainless steel cathode. However, no significant increase in the maximum power density of SMFC with SSN-MWNT anode was detected. Further electrochemical analysis showed that when SSN-MWNT was used as the cathode, the cathodic electrochemical activity and oxygen reduction rate were significantly improved. This study demonstrates that the electrophoretic deposition of carbon nanotubes on conductive substrate can be applied for improving the performance of SMFC.

  4. [Is the use of plastic capillary tubes justified for blood gases analysis?].

    PubMed

    Daurès, Marie-Françoise; Bozonnat, Marie-Cécile; Cristol, Jean-Paul

    2011-01-01

    Some clinical units, such as neonatal or maternity units, preferentially use capillary tubes when analysing blood gases. Using glass tubes is delicate and nurses must recollect blood when breaking. In order to eliminate this problem, we tested flexible, plastic capillary tubes in both the above mentionned units and in our biochemistry laboratory. Each unit, where glass tubes were habitually used, tested 200 flexible, plastic capillary tubes. In addition, the nursing staffed filled out a questionnaire concerned tube usage. Both units clearly preferred using the flexible tubes. In the laboratory, results for blood gas analyses were compared between rigid glass and flexible plastic capillary tubes for 112 patients. Concordance tests did not showed significant differences between the two tube types, except for hematocrit and total haemoglobin. A questionnaire was also presented to the lab technician, who confirmed the easier usability of plastic capillary tubes.

  5. Capillary toroid cavity detector for high pressure NMR

    DOEpatents

    Gerald, II, Rex E.; Chen, Michael J.; Klingler, Robert J.; Rathke, Jerome W.; ter Horst, Marc

    2007-09-11

    A Toroid Cavity Detector (TCD) is provided for implementing nuclear magnetic resonance (NMR) studies of chemical reactions under conditions of high pressures and temperatures. A toroid cavity contains an elongated central conductor extending within the toroid cavity. The toroid cavity and central conductor generate an RF magnetic field for NMR analysis. A flow-through capillary sample container is located within the toroid cavity adjacent to the central conductor to subject a sample material flowing through the capillary to a static magnetic field and to enable NMR spectra to be recorded of the material in the capillary under a temperature and high pressure environment.

  6. RASA1 analysis guides management in a family with capillary malformation-arteriovenous malformation

    PubMed Central

    Flore, Leigh Anne; Leon, Eyby; Maher, Tom A.; Milunsky, Jeff M.

    2012-01-01

    Capillary malformation-arteriovenous malformation (CM-AVM; MIM 60354) is an autosomal dominant disorder characterized by multifocal cutaneous capillary malformations, often in association with fast-flow vascular lesions, which may be cutaneous, subcutaneous, intramuscular, intraosseus, or cerebral arteriovenous malformations or arteriovenous fistulas. CM-AVM results from heterozygous mutations in the RASA1 gene. Capillary malformations of the skin are common, and clinical examination alone may not be able to definitively diagnose-or exclude- CM-AVM. We report a family in which the proband was initially referred for a genetic evaluation in the neonatal period because of the presence of a cardiac murmur and minor dysmorphic features. Both he and his mother were noted to have multiple capillary malformations on the face, head, and extremities. Echocardiography revealed dilated head and neck vessels and magnetic resonance imaging and angiography of the brain revealed a large infratentorial arteriovenous fistula, for which he has had two embolization procedures. RASA1 sequence analysis revealed a heterozygous mutation, confirming his diagnosis of CM-AVM. We established targeted mutation analysis for the proband's mother and sister, the latter of whom is a healthy 3-year-old whose only cutaneous finding is a facial capillary malformation. This revealed that the proband's mother is also heterozygous for the RASA1 mutation, but his sister is negative. Consequently, his mother will undergo magnetic resonance imaging and angiography screening for intracranial and spinal fast-flow lesions, while his sister will require no imaging or serial evaluations. Targeted mutation analysis has been offered to additional maternal family members. This case illustrates the benefit of molecular testing in diagnosis and making screening recommendations for families with CM-AVM. PMID:27625812

  7. RASA1 analysis guides management in a family with capillary malformation-arteriovenous malformation.

    PubMed

    Flore, Leigh Anne; Leon, Eyby; Maher, Tom A; Milunsky, Jeff M

    2012-06-01

    Capillary malformation-arteriovenous malformation (CM-AVM; MIM 60354) is an autosomal dominant disorder characterized by multifocal cutaneous capillary malformations, often in association with fast-flow vascular lesions, which may be cutaneous, subcutaneous, intramuscular, intraosseus, or cerebral arteriovenous malformations or arteriovenous fistulas. CM-AVM results from heterozygous mutations in the RASA1 gene. Capillary malformations of the skin are common, and clinical examination alone may not be able to definitively diagnose-or exclude- CM-AVM. We report a family in which the proband was initially referred for a genetic evaluation in the neonatal period because of the presence of a cardiac murmur and minor dysmorphic features. Both he and his mother were noted to have multiple capillary malformations on the face, head, and extremities. Echocardiography revealed dilated head and neck vessels and magnetic resonance imaging and angiography of the brain revealed a large infratentorial arteriovenous fistula, for which he has had two embolization procedures. RASA1 sequence analysis revealed a heterozygous mutation, confirming his diagnosis of CM-AVM. We established targeted mutation analysis for the proband's mother and sister, the latter of whom is a healthy 3-year-old whose only cutaneous finding is a facial capillary malformation. This revealed that the proband's mother is also heterozygous for the RASA1 mutation, but his sister is negative. Consequently, his mother will undergo magnetic resonance imaging and angiography screening for intracranial and spinal fast-flow lesions, while his sister will require no imaging or serial evaluations. Targeted mutation analysis has been offered to additional maternal family members. This case illustrates the benefit of molecular testing in diagnosis and making screening recommendations for families with CM-AVM.

  8. Electrophoretic and Electrolytic Deposition of Ceramic Particles on Porous Substrates

    DTIC Science & Technology

    1990-08-30

    hydrodynamic drag force exerted on the particle due to the electroosmotic flow of the solvent inside the pore, the electrophoretic force exerted on the...8217 - electrophoretic velocity UN - electroosmotic velocity b - pore mean radius D - diffusion coefficient k - local deposition rate Large Peclet numbers and small...experimentally as the charge is acquired spontaneously on mixing the particles with the solvent and it may be reversed upon addition ot ionic compounds. The

  9. Electrophoretic and Electrolytic Deposition of Ceramic Particles on Porous Substrates

    DTIC Science & Technology

    1992-09-30

    particle penetration is facilitated by the electrophoretic force exerted on it and the electroosmotic flow of the fluid into the pores. 1 2 The...skeleton showed that the whole cross--section of the graphite was impregnated. - The existence of an electroosmotic effect was demonstrated by the...Pe) and the Damkohler number (A): Pe ((U" + Us)b -kb where U" - electrophoretic velocity Um - electroosmotic velocity b - pore mean radius D

  10. Nailfold capillary patterns in healthy subjects: a real issue in capillaroscopy.

    PubMed

    Ingegnoli, Francesca; Gualtierotti, Roberta; Lubatti, Chiara; Bertolazzi, Chiara; Gutierrez, Marwin; Boracchi, Patrizia; Fornili, Marco; De Angelis, Rossella

    2013-11-01

    Nailfold capillaroscopy has been extensively applied in a broad spectrum of pathologic conditions, but very few data have been published in healthy individuals. The aim of this study was to describe the nailfold capillary findings on a large series of healthy subjects using the video-capillaroscopy technique. Nailfold capillaries were studied based on their morphology, dimensions and density. Then, to evaluate jointly the association between different capillary findings in groups of subjects which were homogeneous for their characteristics, cluster analysis was performed. The results (median) of capillary measurements were as follows: loop length 207μm, external diameter 39μm, internal diameter 17μm, apical diameter 17μm, and intercapillary distance 143μm. Based on the cluster analysis three major "normal" morphologic capillaroscopic patterns were depicted: 1) the "normal" pattern mainly with 2 to 5 U-shaped loops/mm and ≤2 tortuous loops/mm; 2) the "perfect normal" pattern with ≥5 U-shaped loops/mm and 3) the "unusual normal" with at least 1 meandering or bushy loop, or at least 1 microhemorrhage, or with >4 crossed loops/mm. Regarding the loop measurements, the majority of subjects had a median of 7capillaries/mm with a median length of 198μm. © 2013 Elsevier Inc. All rights reserved.

  11. Gold nanoparticle incorporated inverse opal photonic crystal capillaries for optofluidic surface enhanced Raman spectroscopy.

    PubMed

    Zhao, Xiangwei; Xue, Jiangyang; Mu, Zhongde; Huang, Yin; Lu, Meng; Gu, Zhongze

    2015-10-15

    Novel transducers are needed for point of care testing (POCT) devices which aim at facile, sensitive and quick acquisition of health related information. Recent advances in optofluidics offer tremendous opportunities for biological/chemical analysis using extremely small sample volumes. This paper demonstrates nanostructured capillary tubes for surface enhanced Raman spectroscopy (SERS) analysis in a flow-through fashion. The capillary tube integrates the SERS sensor and the nanofluidic structure to synergistically offer sample delivery and analysis functions. Inside the capillary tube, inverse opal photonic crystal (IO PhC) was fabricated using the co-assembly approach to form nanoscale liquid pathways. In the nano-voids of the IO PhC, gold nanoparticles were in situ synthesized and functioned as the SERS hotspots. The advantages of the flow-through SERS sensor are multifold. The capillary effect facilities the sample delivery process, the nanofluidic channels boosts the interaction of analyte and gold nanoparticles, and the PhC structure strengthens the optical field near the SERS hotspots and results in enhanced SERS signals from analytes. As an exemplary demonstration, the sensor was used to measure creatinein spiked in artificial urine samples with detection limit of 0.9 mg/dL. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Publications - GMC 385 | Alaska Division of Geological & Geophysical

    Science.gov Websites

    DGGS GMC 385 Publication Details Title: Porosity, permeability, and capillary pressure core analysis Shimer, G., 2011, Porosity, permeability, and capillary pressure core analysis results (2,124'-2,193 -capilar.xls (108.0 K) gmc385-cores-water.xls (19.0 K) Keywords Oil and Gas; Permeability; Porosity Top of Page

  13. Coupling of metal-organic frameworks-containing monolithic capillary-based selective enrichment with matrix-assisted laser desorption ionization-time-of-flight mass spectrometry for efficient analysis of protein phosphorylation.

    PubMed

    Li, Daojin; Yin, Danyang; Chen, Yang; Liu, Zhen

    2017-05-19

    Protein phosphorylation is a major post-translational modification, which plays a vital role in cellular signaling of numerous biological processes. Mass spectrometry (MS) has been an essential tool for the analysis of protein phosphorylation, for which it is a key step to selectively enrich phosphopeptides from complex biological samples. In this study, metal-organic frameworks (MOFs)-based monolithic capillary has been successfully prepared as an effective sorbent for the selective enrichment of phosphopeptides and has been off-line coupled with matrix-assisted laser desorption ionization-time-of-flight mass spectrometry (MALDI-TOF MS) for efficient analysis of phosphopeptides. Using š-casein as a representative phosphoprotein, efficient phosphorylation analysis by this off-line platform was verified. Phosphorylation analysis of a nonfat milk sample was also demonstrated. Through introducing large surface areas and highly ordered pores of MOFs into monolithic column, the MOFs-based monolithic capillary exhibited several significant advantages, such as excellent selectivity toward phosphopeptides, superb tolerance to interference and simple operation procedure. Because of these highly desirable properties, the MOFs-based monolithic capillary could be a useful tool for protein phosphorylation analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Composition and Molecular Weight Distribution of Carob Germ Proteins Fractions

    USDA-ARS?s Scientific Manuscript database

    Biochemical properties of carob germ proteins were analyzed using a combination of selective extraction, reversed-phase high performance liquid chromatography (RP-HPLC), size exclusion chromatography coupled with multi-angle laser light scattering (SEC-MALS) and electrophoretic analysis. Using a mo...

  15. Electrophoretic Analysis of Diversity and Phylogeny of Pinus brutia and Closely Related Taxa

    Treesearch

    M. T. Conkle; G. Schiller; C. Grunwald

    1988-01-01

    Rangewide samples from mature natural stands of Pinus brutia Ten. subsp. brutia, subsp. stankewiczii (Sukaczew) Nahal, subsp. pithyusa (Stevenson) Nahal, and subsp. eldarica (Medw.) Nahal from throughout the eastern Mediterranean display a continuum of allozyme variation for...

  16. Analysis of pilocarpine and its trans epimer, isopilocarpine, by capillary electrophoresis.

    PubMed

    Baeyens, W; Weiss, G; Van Der Weken, G; Van Den Bossche, W

    1993-05-28

    Capillary zone electrophoresis was used for the separation of pilocarpine from its epimer, isopilocarpine, using coated fused-silica capillaries of 20 cm x 25 microm I.D., 8 kV running voltage, migration buffer of 0.1 M sodium dihydrogenphosphate pH 8, detection at 217 nm and injection by electromigration. Injections of aqueous, acid and basic solutions were compared. Linearity of the signal for pilocarpine hydrochloride up to 200 microg ml(-1) in 0.05 M hydrochloric acid was obtained, using naphazoline nitrate as internal standard. Optimization of migration buffer pH using coated silica capillaries of 50 cm x 50 microm I.D. showed that at pH 6.9 pilocarpine can be separated from ++isopilocarpine. Inclusion of beta-cyclodextrin in the buffer allows full baseline separation of both epimers. The method was applied to the analysis of a commercial ophthalmic pilocarpine solution.

  17. Recent advances in combination of capillary electrophoresis with mass spectrometry: methodology and theory.

    PubMed

    Klepárník, Karel

    2015-01-01

    This review focuses on the latest development of microseparation electromigration methods in capillaries and microfluidic devices with MS detection and identification. A wide selection of 183 relevant articles covers the literature published from June 2012 till May 2014 as a continuation of the review article on the same topic by Kleparnik [Electrophoresis 2013, 34, 70-86]. Special attention is paid to the new improvements in the theory of instrumentation and methodology of MS interfacing with capillary versions of zone electrophoresis, ITP, and IEF. Ionization methods in MS include ESI, MALDI, and ICP. Although the main attention is paid to the development of instrumentation and methodology, representative examples illustrate also applications in the proteomics, glycomics, metabolomics, biomarker research, forensics, pharmacology, food analysis, and single-cell analysis. The combinations of MS with capillary versions of electrochromatography and micellar electrokinetic chromatography are not included. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Determination of five active compounds in Artemisia princeps and A. capillaris based on UPLC-DAD and discrimination of two species with multivariate analysis.

    PubMed

    Yang, Heejung; Lee, Dong Young; Jeon, Minji; Suh, Youngbae; Sung, Sang Hyun

    2014-05-01

    Five active compounds, chlorogenic acid, 3,5-di-O-caffeoylquinic acid, 4,5-di-O-caffeoylquinic acid, jaceosidin, and eupatilin, in Artemisia princeps (Compositae) were simultaneously determined by ultra-performance liquid chromatography connected to diode array detector. The morphological resemblance between A. princeps and A. capillaris makes it difficult to properly identify species properly. It occasionally leads to misuse or misapplication in Korean traditional medicine. In the study, the discrimination between A. princeps and A. capillaris was optimally performed by the developed validation method, which resulted in definitely a difference between two species. Also, it was developed the most reliable markers contributing to the discrimination of two species by the multivariate analysis methods, such as a principal component analysis and a partial least squares discrimination analysis.

  19. Fabrication and kinetics study of nano-Al/NiO thermite film by electrophoretic deposition.

    PubMed

    Zhang, Daixiong; Li, Xueming

    2015-05-21

    Nano-Al/NiO thermites were successfully prepared as film by electrophoretic deposition (EPD). For the key issue of this EPD, a mixture solvent of ethanol-acetylacetone (1:1 in volume) containing 0.00025 M nitric acid was proved to be a suitable dispersion system for EPD. The kinetics of electrophoretic deposition for both nano-Al and nano-NiO were investigated; the linear relation between deposition weight and deposition time in short time and parabolic relation in prolonged time were observed in both EPDs. The critical transition time between linear deposition kinetics and parabolic deposition kinetics for nano-Al and nano-NiO were 20 and 10 min, respectively. The theoretical calculation of the kinetics of electrophoretic deposition revealed that the equivalence ratio of nano-Al/NiO thermites film would be affected by the behavior of electrophoretic deposition for nano-Al and nano-NiO. The equivalence ratio remained steady when the linear deposition kinetics dominated for both nano-Al and nano-NiO. The equivalence ratio would change with deposition time when deposition kinetics for nano-NiO changed into parabolic kinetics dominated after 10 min. Therefore, the rule was suggested to be suitable for other EPD of bicomposites. We also studied thermodynamic properties of electrophoretic nano-Al/NiO thermites film as well as combustion performance.

  20. Compound Capillary Flows in Complex Containers: Drop Tower Test Results

    NASA Astrophysics Data System (ADS)

    Bolleddula, Daniel A.; Chen, Yongkang; Semerjian, Ben; Tavan, Noël; Weislogel, Mark M.

    2010-10-01

    Drop towers continue to provide unique capabilities to investigate capillary flow phenomena relevant to terrestrial and space-based capillary fluidics applications. In this study certain `capillary rise' flows and the value of drop tower experimental investigations are briefly reviewed. A new analytic solution for flows along planar interior edges is presented. A selection of test cell geometries are then discussed where compound capillary flows occur spontaneously and simultaneously over local and global length scales. Sample experimental results are provided. Tertiary experiments on a family of asymmetric geometries that isolate the global component of such flows are then presented along with a qualitative analysis that may be used to either avoid or exploit such flows. The latter may also serve as a design tool with which to assess the impact of inadvertent container asymmetry.

  1. Microfabricated plastic chips by hot embossing methods and their applications for DNA separation and detection

    NASA Astrophysics Data System (ADS)

    Lee, Gwo-Bin; Chen, Shu-Hui; Huang, Guan-Ruey; Lin, Yen-Heng; Sung, Wang-Chou

    2000-08-01

    Design and fabrication of microfluidic devices on polymethylmethacrylate (PMMA) substrates using novel microfabrication methods are described. The image of microfluidic devices is transferred from quartz master templates possessing inverse image of the devices to plastic plates by using hot embossing method. The micro channels on master templates are formed by the combination of metal etch mask and wet chemical etching. The micromachined quartz templates can be used repeatedly to fabricate cheap and disposable plastic devices. The reproducibility of the hot embossing method is evaluated after using 10 channels on different plastics. The relative standard deviation of the plastic channel profile from ones on quartz templates is less than 1%. In this study, the PMMA chips have been demonstrated as a micro capillary electrophoresis ((mu) -CE) device for DNA separation and detection. The capability of the fabricated chip for electrophoretic injection and separation is characterized via the analysis of DNA fragments (phi) X174. Results indicate that all of the 11 DNA fragments of the size marker could be identified in less than 3 minutes with relative standard deviations less than 0.4% and 8% for migration time and peak area, respectively. Moreover, with the use of near IR dye, fluorescence signals of the higher molecular weight fragments ($GTR 603 bp in length) could be detected at total DNA concentrations as low as 0.1 (mu) g/mL. In addition to DNA fragments (phi) X174, DNA sizing of hepatitis C viral (HCV) amplicon is also achieved using microchip electrophoresis fabricated on PMMA substrate.

  2. Coinheritance of Hb S [β6(A3)Glu→Val, GAG>GTG] with β0-thalassemia codon 17 (A>T) in a Thai patient.

    PubMed

    Pornprasert, Sakorn; Panyasai, Sitthichai; Kongthai, Kanyakan; Treesuwan, Kallayanee

    2012-01-01

    Hb S [β6(A3)Glu→Val, GAG>GTG] is a β-globin gene variant that has a very low incidence in the Thai population. Coinheritance of Hb S and β(0)-thalassemia (β-thal) can result in severe clinical conditions. This study reports the case of a Thai patient with a compound heterozygosity for Hb S and β(0)-thal codon 17 (A>T). His hemoglobin (Hb), hematocrit (packed cell volume, PCV), mean corpuscular volume (MCV) and mean corpuscular Hb (MCH) levels were all less than the lower limits, while red cell distribution width (RDW) was higher than the upper limit. Levels of Hbs S, F and A(2) detected by high performance liquid chromatography (HPLC) were comparable to those from capillary electrophoresis (CE). As Hb S has a similar electrophoretic mobility and the HPLC profile is also similar to those of Hb Tak [β147, Term→Thr (+AC)] and Hb D-Punjab [β121(GH4)Glu→Gln, GAA>CAA], DNA sequencing was then performed. This was to detect β(0)-thal, and to differentiate Hb S from the Hb Tak and Hb D-Punjab mutations. The β(0)-thal codon 17 and Hb S mutations were detected indicating that coinheritance of these two mutations can be found in the Thai population. Therefore, to provide proper clinical management and genetic counseling of this rare case, DNA analysis should be performed in all cases when a peak at the S-window is detected by HPLC or CE.

  3. Controlled method of reducing electrophoretic mobility of various substances

    NASA Technical Reports Server (NTRS)

    Vanalstine, James M. (Inventor)

    1989-01-01

    A method of reducing electrophoretic mobility of macromolecules, particles, cells, and the like is provided. The method comprises interacting the particles or cells with a polymer-linked affinity compound composed of: a hydrophilic neutral polymer such as polyethylene glycol, and an affinity component consisting of a hydrophobic compound such as a fatty acid ester, an immunocompound such as an antibody or active fragment thereof or simular macromolecule, or other ligands. The reduction of electrophoretic mobility achieved is directly proportional to the concentration of the polymer-linked affinity compound employed, and the mobility reduction obtainable is up to 100 percent for particular particles and cells. The present invention is advantageous in that analytical electrophoretic separation can not be achieved for macromolecules, particles, and cells whose native surface charge structure had prevented them from being separated by normal electrophoretic means. Depending on the affinity component utilized, separation can be achieved on the basis of specific/irreversible, specific/reversible, semi-specific/reversible, relatively nonspecific/reversible, or relatively nonspecific/irreversible ligand-substance interactions. The present method is also advantageous in that it can be used in a variety of standard laboratory electrophoresis equipment.

  4. Preparation and application of microcapsule-encapsulated color electrophortic fluid in Isopar M system for electrophoretic display

    NASA Astrophysics Data System (ADS)

    Sun, Cui; Feng, Ya-Qing; Zhang, Bao; Li, Xiang-Gao; Shao, Ji-Zhou; Han, Jing-Jing; Chen, Xu

    2013-05-01

    The use of Isopar M as a liquid suspending fluid for electrophoretic display was studied. The dispersion stability and chargeability of pigments suspended in Isopar M were investigated. Polyisobutylene monosuccinimide (T-151) as the charge control additive in Isopar M electrophoretic fluid can provide a good electrophoretic mobility to the particles. The wall materials of a series of blue-white, red-white and yellow-white dual-particle microcapsules were prepared by in situ polymerization of urea and formaldehyde. The mass ratio of wall/core material was a key factor in influencing the yield of microcapsules. The concentration of resorcinol has an impact on the surface morphology and mechanical strength of microcapsule wall. Microcapsules' surface morphologies were characterized by optical microscopy and scanning electron microscopy. The performance of the microcapsules with different binder materials and adhesive layers were investigated. Contrast ratio of microcapsules display device were tested every 10 days for a period of 90 days. The compatibility of Isopar M with both the electrophoretic particles and bounding capsule was studied.

  5. Electrophoretic kinetics of concentrated TiO2 nanoparticle suspensions in aprotic solvent

    NASA Astrophysics Data System (ADS)

    Lee, So-Yeon; Yim, Jung-Ryoul; Lee, Se-Hee; Choi, In-Suk; Nam, Ki Tae; Joo, Young-Chang

    2018-01-01

    We studied the dependences of the concentration of additive and particle size on the electrophoretic mobility of TiO2 nanoparticles. A high concentration of TiO2 nanoparticles was dispersed in aprotic solvent, which is similar to the operating conditions of electrophoretic applications. Because spectroscopy has limits to measuring the electrophoretic mobility of concentrated suspensions in aprotic solvents, we developed a new measurement to determine the electrophoretic mobility of particles using the reflectance change according to the motion of the particles. TiO2 nanoparticles with sizes of 31 nm to 164 nm were synthesized by hydrolysis and were dispersed in cyclohexanone with a dye (Sudan Black B) for use in the new measurement method. In a concentrated suspension in aprotic solvent, the mobility of the particles was proportional to the dye concentration and was inversely proportional to the size of the particles. This infers that the particle size influences the drag force rather than the surface charge, and therefore, to increase the mobility by changing the surface charge, an additive is effective. [Figure not available: see fulltext.

  6. Analysis of oligonucleotide photoproducts produced by UV-A light and a riboflavin photosensitizer

    NASA Astrophysics Data System (ADS)

    Gelhaus, Stacy L.; LaCourse, William R.

    2004-12-01

    DNA damage is caused by a variety of foreign and endogenous compounds. There are endogenous photosensitizers in cells, such as porphyrins and flavins, which may create damage in the presence of UV-A light. Typically, samples are analyzed by 32P-postlabelling and electrophoretic separation or by LC-MS separation and detection. Separation by HPLC is common; however, in all instances, the DNA sample is hydrolyzed down to nucleosides prior to analysis. It will be shown here that ion-pairing reversed phase high performance liquid chromatography (IP-RPLC) has the ability to provide biophysical information concerning the sites of UV-A induced photosensitizer damage on an intact oligonucleotide concurrent with the separation. IP-RPLC is less labor intensive and faster than electrophoretic methods and it is less costly than LC-MS. IP-RPLC can also be used to purify modified oligonucleotides for further use and analysis. This technique is sensitive to the charge, conformation, and sequence characteristics of the nucleic acid sample and may be used to determine the damage or modifications made to DNA by a variety of compounds.

  7. Structure of Particle Networks in Capillary Suspensions with Wetting and Nonwetting Fluids

    PubMed Central

    2016-01-01

    The mechanical properties of a suspension can be dramatically altered by adding a small amount of a secondary fluid that is immiscible with the bulk phase. The substantial changes in the strength of these capillary suspensions arise due to the capillary force inducing a percolating particle network. Spatial information on the structure of the particle networks is obtained using confocal microscopy. It is possible, for the first time, to visualize the different types of percolating structures of capillary suspensions in situ. These capillary networks are unique from other types of particulate networks due to the nature of the capillary attraction. We investigate the influence of the three-phase contact angle on the structure of an oil-based capillary suspension with silica microspheres. Contact angles smaller than 90° lead to pendular networks of particles connected with single capillary bridges or clusters comparable to the funicular state in wet granular matter, whereas a different clustered structure, the capillary state, forms for angles larger than 90°. Particle pair distribution functions are obtained by image analysis, which demonstrate differences in the network microstructures. When porous particles are used, the pendular conformation also appears for apparent contact angles larger than 90°. The complex shear modulus can be correlated to these microstructural changes. When the percolating structure is formed, the complex shear modulus increases by nearly three decades. Pendular bridges lead to stronger networks than the capillary state network conformations, but the capillary state clusters are nevertheless much stronger than pure suspensions without the added liquid. PMID:26807651

  8. Free-zone electrophoresis of animal cells. 1: Experiments on cell-cell interactions

    NASA Technical Reports Server (NTRS)

    Todd, P. W.; Hjerten, S.

    1985-01-01

    The electrophoretically migrating zones wasa monitored. The absence of fluid flows in the direction of migration permits direct measurement of electrophoretic velocities of any material. Sedimentation is orthogonal to electrokinetic motion and the effects of particle-particle interaction on electrophoretic mobility is studied by free zone electrophoresis. Fixed erythrocytes at high concentrations, mixtures of fixed erythrocytes from different animal species, and mixtures of cultured human cells were studied in low ionic strength buffers. The electrophoretic velocity of fixed erythrocytes was not altered by increasing cell concentration or by the mixing of erythrocytes from different species. When zones containing cultured human glial cells and neuroblastoma cells are permitted to interact during electrophoresis, altered migration patterns occur. It is found that cell-cell interactions depends upon cell type.

  9. Integrated microfluidic chip for rapid DNA digestion and time-resolved capillary electrophoresis analysis

    PubMed Central

    Lin, Che-Hsin; Wang, Yao-Nan; Fu, Lung-Ming

    2012-01-01

    An integrated microfluidic chip is proposed for rapid DNA digestion and time-resolved capillary electrophoresis (CE) analysis. The chip comprises two gel-filled chambers for DNA enrichment and purification, respectively, a T-form micromixer for DNA/restriction enzyme mixing, a serpentine channel for DNA digestion reaction, and a CE channel for on-line capillary electrophoresis analysis. The DNA and restriction enzyme are mixed electroomostically using a pinched-switching DC field. The experimental and numerical results show that a mixing performance of 97% is achieved within a distance of 1 mm from the T-junction when a driving voltage of 90 V/cm and a switching frequency of 4 Hz are applied. Successive mixing digestion and capillary electrophoresis operation clearly present the changes on digesting φx-174 DNA in different CE runs. The time-resolved electropherograms show that the proposed device enables a φx-174 DNA sample comprising 11 fragments to be concentrated and analyzed within 24 min. Overall, the results presented in this study show that the proposed microfluidic chip provides a rapid and effective tool for DNA digestion and CE analysis applications. PMID:22662085

  10. Metallomesogenic stationary phase for open-tubular capillary electrochromatography.

    PubMed

    Chen, Jian-Lian

    2006-02-01

    A synthetic coppermesogenic polymer is prepared and then covalently bonded to the siloxane-based deactivated column as the stationary phases of open-tubular CEC with essentially high phase ratio. The EOF generated from the modified phase is surveyed through conventional aqueous buffers and hydroorganic mobile phases. Zeta potentials, which are computed from the EOF data and the ratio of dielectric constant to viscosity, are plotted as a function of pH, ionic molarity, and compositional range. These plots responsible for the electroosmotic characteristic of the bonded phases are found to be like those of bare fused-silica or deactivated columns through decreasing or increasing the ACN content in the mobile phase, respectively. This two-phase characteristic is basically derived from the polymeric configuration with carboxylato ligands attached onto the polysiloxane backbone. Phthalates and amino acids are suitable probes to examine the two phenomena, more-polar and less-polar mediums, respectively, and to judge whether the chromatographic retention is the major source of separation mechanism. With the mixing modes of Lewis acid-base interaction, dispersive force, and shape discrimination, the chromatographic partition adequately accomplishes the uneasily resolved separations by only CZE mode, although the electrophoretic migration is truly somewhat involved.

  11. Capillary electrochromatographic separation of peptides using a macrocyclic polyamine for molecular recognition.

    PubMed

    Chen, Tse-Hsien; Misra, Tarun Kumar; Liu, Chuen-Ying

    2008-04-01

    A macrocyclic polyamine, 1,5,9,13,17,21,25,29-octaazacyclodotriacontane ([32]ane-N(8)), in the bonded phase was employed as a molecular receptor for CEC separation of oligopeptides. Parameters affecting the performance of the separations were considered. Baseline separation for the mixture of angiotensin I, angiotensin II, [Sar(1), Thr(8)]-angiotensin II, beta-casomorphin bovine, beta-casomorphin human, oxytocin acetate, tocinoic acid, vasopressin, and FMRF amide could be achieved using phosphate buffer (30 mM, pH 7) as the mobile phase. Column efficiency with average theoretical plate numbers of 69 000 plates/m and RSDs of <1% (n = 6) was achieved. [Met(5)]-enkephalin and [Leu(5)]-enkephalin, which have identical pI values and similar masses could be completely separated using acetate buffer (30 mM) with pH gradient (pH 3 inlet side and pH 4 outlet side). The results suggest that the mechanism for the peptide separation was mediated by a combination of electrophoretic migration and chromatographic retention involving anion coordination and anion exchange. After long-term use, the deviation of the EOF of the column after more than 600 injections was still within 6.0% of that for a freshly prepared column.

  12. The Cutting Edge of Affinity Electrophoresis Technology

    PubMed Central

    Kinoshita, Eiji; Kinoshita-Kikuta, Emiko; Koike, Tohru

    2015-01-01

    Affinity electrophoresis is an important technique that is widely used to separate and analyze biomolecules in the fields of biology and medicine. Both quantitative and qualitative information can be gained through affinity electrophoresis. Affinity electrophoresis can be applied through a variety of strategies, such as mobility shift electrophoresis, charge shift electrophoresis or capillary affinity electrophoresis. These strategies are based on changes in the electrophoretic patterns of biological macromolecules that result from interactions or complex-formation processes that induce changes in the size or total charge of the molecules. Nucleic acid fragments can be characterized through their affinity to other molecules, for example transcriptional factor proteins. Hydrophobic membrane proteins can be identified by means of a shift in the mobility induced by a charged detergent. The various strategies have also been used in the estimation of association/disassociation constants. Some of these strategies have similarities to affinity chromatography, in that they use a probe or ligand immobilized on a supported matrix for electrophoresis. Such methods have recently contributed to profiling of major posttranslational modifications of proteins, such as glycosylation or phosphorylation. Here, we describe advances in analytical techniques involving affinity electrophoresis that have appeared during the last five years. PMID:28248262

  13. Effect of using polyimide capillaries during thermal experiments on the particle size distribution of supported Pt nanoparticles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gámez-Mendoza, Liliana; Resto, Oscar; Martínez-Iñesta, María

    2015-09-20

    Kapton HN-type polyimide capillaries are commonly used as sample holders for transmission X-ray experiments at temperatures below 673 K because of their thermal stability, high X-ray transmittance and low cost. Using high-angle annular dark field scanning high-resolution transmission electron microscopy and thermogravimetric analysis, this work shows that using polyimide capillaries leads to the overgrowth of supported Pt nanoparticles during reduction at temperatures below the glass transition temperature (T g= 658 K) owing to an outgassing of water from the polyimide. Quartz capillaries were also studied and this overgrowth was not observed.

  14. Electrophoretic deposition of graphene oxide reinforced chitosan-hydroxyapatite nanocomposite coatings on Ti substrate.

    PubMed

    Shi, Y Y; Li, M; Liu, Q; Jia, Z J; Xu, X C; Cheng, Y; Zheng, Y F

    2016-03-01

    Electrophoretic deposition (EPD) is a facile and feasible technique to prepare functional nanocomposite coatings for application in orthopedic-related implants. In this work, a ternary graphene oxide-chitosan-hydroxyapatite (GO-CS-HA) composite coating on Ti substrate was successfully fabricated by EPD. Coating microstructure and morphologies were investigated by scanning electron microscopy, contact angle test, Raman spectroscopy, Fourier transform infrared spectroscopy and thermogravimetric analysis. It was found GO-CS surface were uniformly decorated by HA nanoparticles. The potentiodynamic polarization test in simulated body fluid indicated that the GO-CS-HA coatings could provide effective protection of Ti substrate from corrosion. This ternary composite coating also exhibited good biocompatibility during incubation with MG63 cells. In addition, the nanocomposite coatings could decrease the attachment of Staphylococcus aureus.

  15. Insight into nanoparticle charging mechanism in nonpolar solvents to control the formation of Pt nanoparticle monolayers by electrophoretic deposition

    DOE PAGES

    Cernohorsky, Ondrej; Grym, Jan; Yatskiv, Roman; ...

    2016-08-13

    We report on the formation of Pt nanoparticle monolayers by electrophoretic deposition from nonpolar solvents. First, the growth kinetics of Pt nanoparticles prepared by the reverse micelle technique are described in detail. Second, a model of nanoparticle charging in nonpolar media is discussed and methods to control the nanoparticle charging are proposed. Lastly, essential parameters of the electrophoretic deposition process to control the deposition of nanoparticle monolayers are discussed and mechanisms of their formation are analyzed.

  16. Insight into nanoparticle charging mechanism in nonpolar solvents to control the formation of Pt nanoparticle monolayers by electrophoretic deposition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cernohorsky, Ondrej; Grym, Jan; Yatskiv, Roman

    We report on the formation of Pt nanoparticle monolayers by electrophoretic deposition from nonpolar solvents. First, the growth kinetics of Pt nanoparticles prepared by the reverse micelle technique are described in detail. Second, a model of nanoparticle charging in nonpolar media is discussed and methods to control the nanoparticle charging are proposed. Lastly, essential parameters of the electrophoretic deposition process to control the deposition of nanoparticle monolayers are discussed and mechanisms of their formation are analyzed.

  17. IB-LBM simulation of the haemocyte dynamics in a stenotic capillary.

    PubMed

    Yuan-Qing, Xu; Xiao-Ying, Tang; Fang-Bao, Tian; Yu-Hua, Peng; Yong, Xu; Yan-Jun, Zeng

    2014-01-01

    To study the behaviour of a haemocyte when crossing a stenotic capillary, the immersed boundary-lattice Boltzmann method was used to establish a quantitative analysis model. The haemocyte was assumed to be spherical and to have an elastic cell membrane, which can be driven by blood flow to adopt a highly deformable character. In the stenotic capillary, the spherical blood cell was stressed both by the flow and the wall dimension, and the cell shape was forced to be stretched to cross the stenosis. Our simulation investigated the haemocyte crossing process in detail. The velocity and pressure were anatomised to obtain information on how blood flows through a capillary and to estimate the degree of cell damage caused by excessive pressure. Quantitative velocity analysis results demonstrated that a large haemocyte crossing a small stenosis would have a noticeable effect on blood flow, while quantitative pressure distribution analysis results indicated that the crossing process would produce a special pressure distribution in the cell interior and to some extent a sudden change between the cell interior and the surrounding plasma.

  18. Heparin/heparan sulfate analysis by covalently modified reverse polarity capillary zone electrophoresis-mass spectrometry.

    PubMed

    Sanderson, Patience; Stickney, Morgan; Leach, Franklin E; Xia, Qiangwei; Yu, Yanlei; Zhang, Fuming; Linhardt, Robert J; Amster, I Jonathan

    2018-04-13

    Reverse polarity capillary zone electrophoresis coupled to negative ion mode mass spectrometry (CZE-MS) is shown to be an effective and sensitive tool for the analysis of glycosaminoglycan mixtures. Covalent modification of the inner wall of the separation capillary with neutral or cationic reagents produces a stable and durable surface that provides reproducible separations. By combining CZE-MS with a cation-coated capillary and a sheath flow interface, a rapid and reliable method has been developed for the analysis of sulfated oligosaccharides from dp4 to dp12. Several different mixtures have been separated and detected by mass spectrometry. The mixtures were selected to test the capability of this approach to resolve subtle differences in structure, such as sulfation position and epimeric variation of the uronic acid. The system was applied to a complex mixture of heparin/heparan sulfate oligosaccharides varying in chain length from dp3 to dp12 and more than 80 molecular compositions were identified by accurate mass measurement. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. A novel in situ strategy for the preparation of a β-cyclodextrin/polydopamine-coated capillary column for capillary electrochromatography enantioseparations.

    PubMed

    Guo, Heying; Niu, Xiaoying; Pan, Congjie; Yi, Tao; Chen, Hongli; Chen, Xingguo

    2017-06-01

    Inspired by the chiral recognition ability of β-cyclodextrin and the natural adhesive properties of polydopamine under alkaline conditions, in this study, a rapid and in situ modification strategy was developed to fabricate β-cyclodextrin/polydopamine composite material coated-capillary columns for open tubular capillary electrochromatography. The results of scanning electron microscopy, FTIR spectroscopy, streaming potential, and electro-osmotic flow studies indicated that β-cyclodextrin/polydopamine was successfully fixed on the inner wall of the capillary column. This coating can be achieved within 1 h affording a greatly reduced capillary preparation time. The performance of the β-cyclodextrin/polydopamine-coated capillary was validated by the analysis of seven pairs of chiral analytes, namely epinephrine, norepinephrine, isoprenaline, terbutaline, verapamil, tryptophane, carvedilol. Good enantioseparation efficiencies were achieved for all. For three consecutive runs, the relative standard deviations for the migration times of the analytes for intraday, interday, and column-to-column repeatability were in the range of 0.41-1.74, 1.03-4.18, and 1.66-8.24%, respectively. Moreover, the separation efficiency of the β-cyclodextrin/polydopamine-coated capillary column did not decrease obviously over 90 runs. The strategy should also be feasible to introduce and immobilize other chiral selectors on the inner walls surface of capillary columns. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Investigation of the acid-base and electromigration properties of 5-azacytosine derivatives using capillary electrophoresis and density functional theory calculations.

    PubMed

    Geffertová, Denisa; Ali, Syed Tahir; Šolínová, Veronika; Krečmerová, Marcela; Holý, Antonín; Havlas, Zdeněk; Kašička, Václav

    2017-01-06

    Capillary electrophoresis (CE) and quantum mechanical density functional theory (DFT) were applied to the investigation of the acid-base and electromigration properties of important compounds: newly synthesized derivatives of 5-azacytosine - analogs of efficient antiviral drug cidofovir. These compounds exhibit a strong antiviral activity and they are considered as potential new antiviral agents. For their characterization and application, it is necessary to know their acid-base properties, particularly the acidity constants (pK a ) of their ionogenic groups (the basic N 3 atom of the triazine ring and the acidic phosphonic acid group in the alkyl chain). First, the mixed acidity constants (pK a mix ) of these ionogenic groups and the ionic mobilities of these compounds were determined by nonlinear regression analysis of the pH dependence of their effective electrophoretic mobilities. Effective mobilities were measured by CE in a series of background electrolytes in a wide pH range (2.0-10.5), at constant ionic strength (25mM) and constant temperature (25°C). Subsequently, the pK a mix values were recalculated to thermodynamic pK a values using the Debye-Hückel theory. The thermodynamic pK a value of the NH + moiety at the N 3 atom of the triazine ring was found to be in the range 2.82-3.30, whereas the pK a of the hydrogenphosphonate group reached values from 7.19 to 7.47, depending on the structure of the analyzed compounds. These experimentally determined pK a values were in good agreement with those calculated by quantum mechanical DFT. In addition, DFT calculations revealed that from the four nitrogen atoms in the 5-azacytosine moiety, the N 3 atom of the triazine ring is preferentially protonated. Effective charges of analyzed compounds ranged from zero or close-to-zero values at pH 2 to -2 elementary charges at pH≥9. Ionic mobilities were in the range (-16.7 to -19.1)×10 -9 m 2 V -1 s -1 for univalent anions and in the interval (-26.9 to -30.3)×10 -9 m 2 V -1 s -1 for divalent anions. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Study of the efficiency for ion transfer through bent capillaries.

    PubMed

    Chen, Tsung-Chi; Xu, Wei; Garimella, Sandilya; Ouyang, Zheng

    2012-11-01

    Discontinuous atmospheric pressure interfaces (DAPIs) with bent capillaries represent a highly simplified and flexible means for introducing ions into a vacuum manifold for mass analysis or gas phase ion reactions. In this work, a series of capillaries of different radians and curvatures were used with DAPI for studying the impact of the capillary bending on the ion transfer. The variation of transfer efficiency was systematically characterized for dry and solvated ions. The efficiency loss for dry ions was less than one order of magnitude, even with a three-turn bent capillary. The transfer of solvated ions generated by electrospray was found to be minimally impacted by the bending of the transfer capillary. For multiply protonated ions, the transfer efficiency for ions at lower charge states could be relatively well retained, presumably due to the lower reactivity associated with proton transfer reaction and the compensation in intensity by conversion of ions at higher charge states. Copyright © 2012 John Wiley & Sons, Ltd.

  2. Van der waals forces on thin liquid films in capillary tubes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Herdt, G.C.; Swanson, L.W.

    1993-10-01

    A theory of the van der Waals attraction between a thin liquid films and a capillary tube is presented assuming the presence of a vapor-liquid interface. The model is based on the surface mode analysis method of van Kampen et al. Values for the van der Waals interaction energy per unit area were calculated for liquid films of pentane on a gold substrate assuming a thin liquid film. Results indicate that the effect of capillary curvature on the van der Waals interaction increases as the ratio of the liquid film thickness to the capillary radius is increased. This trend ismore » consistent with predictions based on the Hamaker theory. Deviations from results based on the Hamaker theory are easily explained in terms of retardation of the van der Waals interaction. Because the effect of capillary curvature increases in the regime where retardation effects become important, curvature effects constitute a small correction to the van der Waals forces in a capillary tube.« less

  3. Universal microfluidic automaton for autonomous sample processing: application to the Mars Organic Analyzer.

    PubMed

    Kim, Jungkyu; Jensen, Erik C; Stockton, Amanda M; Mathies, Richard A

    2013-08-20

    A fully integrated multilayer microfluidic chemical analyzer for automated sample processing and labeling, as well as analysis using capillary zone electrophoresis is developed and characterized. Using lifting gate microfluidic control valve technology, a microfluidic automaton consisting of a two-dimensional microvalve cellular array is fabricated with soft lithography in a format that enables facile integration with a microfluidic capillary electrophoresis device. The programmable sample processor performs precise mixing, metering, and routing operations that can be combined to achieve automation of complex and diverse assay protocols. Sample labeling protocols for amino acid, aldehyde/ketone and carboxylic acid analysis are performed automatically followed by automated transfer and analysis by the integrated microfluidic capillary electrophoresis chip. Equivalent performance to off-chip sample processing is demonstrated for each compound class; the automated analysis resulted in a limit of detection of ~16 nM for amino acids. Our microfluidic automaton provides a fully automated, portable microfluidic analysis system capable of autonomous analysis of diverse compound classes in challenging environments.

  4. Role of capillary electrophoresis in the fight against doping in sports.

    PubMed

    Harrison, Christopher R

    2013-08-06

    At present the role of capillary electrophoresis in the detection of doping agents in athletes is, for the most part, nonexistent. More traditional techniques, namely gas and liquid chromatography with mass spectrometric detection, remain the gold standard of antidoping tests. This Feature will investigate the in-roads that capillary electrophoresis has made, the limitations that the technique suffers from, and where the technique may grow into being a key tool for antidoping analysis.

  5. Analysis of Alkaloids from Physalis peruviana by Capillary GC, Capillary GC-MS, and GC-FTIR.

    PubMed

    Kubwabo, C; Rollmann, B; Tilquin, B

    1993-04-01

    The alkaloid composition of the aerial parts and roots of PHYSALIS PERUVIANA was analysed by capillary GC (GC (2)), GC (2)-MS and GC (2)-FTIR. Eight alkaloids were identified, three of those alkaloids are 3beta-acetoxytropane and two N-methylpyrrolidinylhygrine isomers, which were not previously found in the genus PHYSALIS. A reproduction of the identification of alkaloids detected in the plant by the use of retention indices has been proposed.

  6. CE-MS analysis of heroin and its basic impurities using a charged polymer-protected gold nanoparticle-coated capillary.

    PubMed

    Zhang, Zhengxiang; Yan, Bo; Liu, Kelin; Liao, Yiping; Liu, Huwei

    2009-01-01

    The first application of charged polymer-protected gold nanoparticles (Au NPs) as semi-permanent capillary coating in CE-MS was presented. Poly(diallyldimethylammonium chloride) (PDDA) was the only reducing and stabilizing agent for Au NPs preparation. Stable and repeatable coating with good tolerance to 0.1 M HCl, methanol, and ACN was obtained via a simple rinsing procedure. Au NPs enhanced the coating stability toward flushing by methanol, improved the run-to-run and capillary-to-capillary repeatabilities, and improved the separation efficiency of heroin and its basic impurities for tracing geographical origins of illicit samples. Baseline resolution of eight heroin-related alkaloids was achieved on the PDDA-protected Au NPs-coated capillary under the optimum conditions: 120 mM ammonium acetate (pH 5.2) with addition of 13% methanol, separation temperature 20 degrees C, applied voltage -20 kV, and capillary effective length 60.0 cm. CE-MS analysis with run-to-run RSDs (n=5) of migration time in the range of 0.43-0.62% and RSDs (n=5) of peak area in the range of 1.49-4.68% was obtained. The established CE-MS method would offer sensitive detection and confident identification of heroin and related compounds and provide an alternative to LC-MS and GC-MS for illicit drug control.

  7. Direct Analysis of Organic Compounds in Liquid Using a Miniature Photoionization Ion Trap Mass Spectrometer with Pulsed Carrier-Gas Capillary Inlet.

    PubMed

    Lu, Xinqiong; Yu, Quan; Zhang, Qian; Ni, Kai; Qian, Xiang; Tang, Fei; Wang, Xiaohao

    2017-08-01

    A miniature ion trap mass spectrometer with capillary direct sampling and vacuum ultraviolet photoionization source was developed to conduct trace analysis of organic compounds in liquids. Self-aspiration sampling is available where the samples are drawn into the vacuum chamber through a capillary with an extremely low flow rate (less than 1 μL/min), which minimizes sample consumption in each analysis to tens of micrograms. A pulsed gas-assisted inlet was designed and optimized to promote sample transmission in the tube and facilitate the cooling of ions, thereby improving instrument sensitivity. A limit of detection of 2 ppb could be achieved for 2,4-dimethylaniline in a methanol solution. The sampling system described in the present study is specifically suitable for a miniature photoionization ion trap mass spectrometer that can perform rapid and online analysis for liquid samples. Graphical Abstract ᅟ.

  8. Direct Analysis of Organic Compounds in Liquid Using a Miniature Photoionization Ion Trap Mass Spectrometer with Pulsed Carrier-Gas Capillary Inlet

    NASA Astrophysics Data System (ADS)

    Lu, Xinqiong; Yu, Quan; Zhang, Qian; Ni, Kai; Qian, Xiang; Tang, Fei; Wang, Xiaohao

    2017-08-01

    A miniature ion trap mass spectrometer with capillary direct sampling and vacuum ultraviolet photoionization source was developed to conduct trace analysis of organic compounds in liquids. Self-aspiration sampling is available where the samples are drawn into the vacuum chamber through a capillary with an extremely low flow rate (less than 1 μL/min), which minimizes sample consumption in each analysis to tens of micrograms. A pulsed gas-assisted inlet was designed and optimized to promote sample transmission in the tube and facilitate the cooling of ions, thereby improving instrument sensitivity. A limit of detection of 2 ppb could be achieved for 2,4-dimethylaniline in a methanol solution. The sampling system described in the present study is specifically suitable for a miniature photoionization ion trap mass spectrometer that can perform rapid and online analysis for liquid samples.

  9. Application of Partial Internal Transcribed Spacer Sequences for the Discrimination of Artemisia capillaris from Other Artemisia Species

    PubMed Central

    Doh, Eui Jeong; Paek, Seung-Ho; Lee, Guemsan; Lee, Mi-Young; Oh, Seung-Eun

    2016-01-01

    Several Artemisia species are used as herbal medicines including the dried aerial parts of Artemisia capillaris, which are used as Artemisiae Capillaris Herba (known as “Injinho” in Korean medicinal terminology and “Yin Chen Hao” in Chinese). In this study, we developed tools for distinguishing between A. capillaris and 11 other Artemisia species that grow and/or are cultured in China, Japan, and Korea. Based on partial nucleotide sequences in the internal transcribed spacer (ITS) that differ between the species, we designed primers to amplify a DNA marker for A. capillaris. In addition, to detect other Artemisia species that are contaminants of A. capillaris, we designed primers to amplify DNA markers of A. japonica, A. annua, A. apiacea, and A. anomala. Moreover, based on random amplified polymorphic DNA analysis, we confirmed that primers developed in a previous study could be used to identify Artemisia species that are sources of Artemisiae Argyi Folium and Artemisiae Iwayomogii Herba. By using these primers, we found that multiplex polymerase chain reaction (PCR) was a reliable tool to distinguish between A. capillaris and other Artemisia species and to identify other Artemisia species as contaminants of A. capillaris in a single PCR. PMID:27313651

  10. Scaling analysis and SE simulation of the tilted cylinder-interface capillary interaction

    NASA Astrophysics Data System (ADS)

    Gao, S. Q.; Zhang, X. Y.; Zhou, Y. H.

    2018-06-01

    The capillary interaction induced by a tilted cylinder and interface is the basic configuration of many complex systems, such as micro-pillar arrays clustering, super-hydrophobicity of hairy surface, water-walking insects, and fiber aggregation. We systematically analyzed the scaling laws of tilt angle, contact angle, and cylinder radius on the contact line shape by SE simulation and experiment. The following in-depth analysis of the characteristic parameters (shift, stretch and distortion) of the deformed contact lines reveals the self-similar shape of contact line. Then a general capillary force scaling law is proposed to incredibly grasp all the simulated and experimental data by a quite straightforward ellipse approximation approach.

  11. In-air PIXE analysis by means of glass capillary optics

    NASA Astrophysics Data System (ADS)

    Nebiki, Takuya; Kabir, M. Hasnat; Narusawa, Tadashi

    2006-08-01

    A novel technique to introduce high energy ion beams to atmospheric environment is presented, which enables in-air PIXE measurements. Slightly tapered glass capillary optics is applied to work as a differential pumping orifice as well as a focusing lens. The flux intensity is enhanced by at least one order of magnitude due to the focusing effect. Using capillaries of 10-20 μm outlet diameters, we obtain several hundreds pA of 4 MeV He2+ ion beam and apply it to PIXE analysis of the seabed sludge without any sample treatments. A comparison of spectra between wet and dry sludge samples suggests the usefulness of our new technique.

  12. Electrophoretic manipulation of multiple-emulsion droplets

    NASA Astrophysics Data System (ADS)

    Schoeler, Andreas M.; Josephides, Dimitris N.; Chaurasia, Ankur S.; Sajjadi, Shahriar; Mesquida, Patrick

    2014-02-01

    Electrophoretic manipulation of multiple-emulsion oil-in-water-in-oil (O/W)/O and water-in-oil-in-water-in-oil (W/O/W)/O core-shell droplets is shown. It was found that the electrophoretic mobility of the droplets is determined solely by the outer water shell, regardless of size or composition of the inner droplets. It was observed that the surface charge of the outer water shell can be changed and the polarity can be reversed through contact with a biased electrode in a similar way as with simple W/O droplets. Furthermore, addition of the anionic surfactant, sodium dodecyl sulfate to the outer water shell reverses the initial polarity and hence, electrophoretic mobility of the core-shell droplets before contact with an electrode. The results have practical implications for the manipulation of oil droplets in a continuous oil phase.

  13. Population genetic analysis of oral treponemes by multilocus enzyme electrophoresis.

    PubMed

    Dahle, U R; Olsen, I; Tronstad, L; Caugant, D A

    1995-10-01

    Seventeen treponemes recently isolated from necrotic pulps, periodontal and periapical infections and 17 previously well characterized oral treponemal strains were analyzed by multilocus enzyme electrophoresis. Ten genetic loci were characterized on the basis of the electrophoretic mobilities of their enzymatic products. All loci were polymorphic. The average number of alleles per locus was 7.8. The genetic diversity among the electrophoretic types at each locus ranged from 0.624 to 0.836 with a mean genetic diversity per locus of 0.751. The 34 strains represented 34 electrophoretic types, constituting 6 main divisions (I-VI) separated at genetic distances greater than 0.75. Several of the previously characterized treponemes revealed multiple bands of enzyme activity at several loci, indicating that they were not pure. The characterized strains usually clustered within established species, whereas fresh clinical isolates overlapped species borders. There was a large genetic difference between some reference and clinical strains, indicating that the latter may contain undescribed species. Treponema socranskii and Treponema denticola strains clustered in distinct divisions (IV and V, respectively), with the exception of T. denticola strain FDC 51B2 and T. socranskii subsp. paredis strain VPI D46CPE1, both previously well described. This indicated that the taxonomic assignment of these 2 strains should be reconsidered.

  14. Microvascular remodelling in preeclampsia: quantifying capillary rarefaction accurately and independently predicts preeclampsia.

    PubMed

    Antonios, Tarek F T; Nama, Vivek; Wang, Duolao; Manyonda, Isaac T

    2013-09-01

    Preeclampsia is a major cause of maternal and neonatal mortality and morbidity. The incidence of preeclampsia seems to be rising because of increased prevalence of predisposing disorders, such as essential hypertension, diabetes, and obesity, and there is increasing evidence to suggest widespread microcirculatory abnormalities before the onset of preeclampsia. We hypothesized that quantifying capillary rarefaction could be helpful in the clinical prediction of preeclampsia. We measured skin capillary density according to a well-validated protocol at 5 consecutive predetermined visits in 322 consecutive white women, of whom 16 subjects developed preeclampsia. We found that structural capillary rarefaction at 20-24 weeks of gestation yielded a sensitivity of 0.87 with a specificity of 0.50 at the cutoff of 2 capillaries/field with the area under the curve of the receiver operating characteristic value of 0.70, whereas capillary rarefaction at 27-32 weeks of gestation yielded a sensitivity of 0.75 and a higher specificity of 0.77 at the cutoff of 8 capillaries/field with area under the curve of the receiver operating characteristic value of 0.82. Combining capillary rarefaction with uterine artery Doppler pulsatility index increased the sensitivity and specificity of the prediction. Multivariable analysis shows that the odds of preeclampsia are increased in women with previous history of preeclampsia or chronic hypertension and in those with increased uterine artery Doppler pulsatility index, but the most powerful and independent predictor of preeclampsia was capillary rarefaction at 27-32 weeks. Quantifying structural rarefaction of skin capillaries in pregnancy is a potentially useful clinical marker for the prediction of preeclampsia.

  15. Noninvasive imaging of human foveal capillary network using dual-conjugate adaptive optics.

    PubMed

    Popovic, Zoran; Knutsson, Per; Thaung, Jörgen; Owner-Petersen, Mette; Sjöstrand, Johan

    2011-04-22

    To demonstrate noninvasive imaging of human foveal capillary networks with a high-resolution, wide-field, dual-conjugate adaptive optics (DCAO) imaging instrument. The foveal capillary networks of five healthy subjects with no previous history of ocular or neurologic disease or surgery were imaged with a novel high-resolution, wide-field DCAO instrument. The foveal avascular zone (FAZ) in each image was defined using a manual procedure. An automated algorithm based on publicly available and custom-written software was used to identify vessels and extract morphologic FAZ and vessel parameters. Capillary densities were calculated in two annular regions of interest (ROIs) outside the FAZ (500 μm and 750 μm outer radius from the foveal center) and in the superior, inferior, temporal, and nasal quadrants within the two ROIs. Mean FAZ area was 0.302 ± 0.100 mm(2), and mean capillary density (length/area) in the inner ROI was 38.0 ± 4.0 mm(-1) and 36.4 ± 4.0 mm(-1) in the outer ROI. The difference in ROI capillary density was not significant. There was no significant difference in quadrant capillary density within the two ROIs or between quadrants irrespective of ROI. The authors have demonstrated a technique for noninvasive imaging and semiautomated detection and analysis of foveal capillaries. In comparison with other studies, their method yielded lower capillary densities than histology but similar results to the current clinical gold standard, fluorescein angiography. The increased field of view of the DCAO instrument opens up new possibilities for high-resolution noninvasive clinical imaging of foveal capillaries.

  16. Capillary Rise: Validity of the Dynamic Contact Angle Models.

    PubMed

    Wu, Pingkeng; Nikolov, Alex D; Wasan, Darsh T

    2017-08-15

    The classical Lucas-Washburn-Rideal (LWR) equation, using the equilibrium contact angle, predicts a faster capillary rise process than experiments in many cases. The major contributor to the faster prediction is believed to be the velocity dependent dynamic contact angle. In this work, we investigated the dynamic contact angle models for their ability to correct the dynamic contact angle effect in the capillary rise process. We conducted capillary rise experiments of various wetting liquids in borosilicate glass capillaries and compared the model predictions with our experimental data. The results show that the LWR equations modified by the molecular kinetic theory and hydrodynamic model provide good predictions on the capillary rise of all the testing liquids with fitting parameters, while the one modified by Joos' empirical equation works for specific liquids, such as silicone oils. The LWR equation modified by molecular self-layering model predicts well the capillary rise of carbon tetrachloride, octamethylcyclotetrasiloxane, and n-alkanes with the molecular diameter or measured solvation force data. The molecular self-layering model modified LWR equation also has good predictions on the capillary rise of silicone oils covering a wide range of bulk viscosities with the same key parameter W(0), which results from the molecular self-layering. The advantage of the molecular self-layering model over the other models reveals the importance of the layered molecularly thin wetting film ahead of the main meniscus in the energy dissipation associated with dynamic contact angle. The analysis of the capillary rise of silicone oils with a wide range of bulk viscosities provides new insights into the capillary dynamics of polymer melts.

  17. Optical coherence tomography angiography-based capillary velocimetry

    NASA Astrophysics Data System (ADS)

    Wang, Ruikang K.; Zhang, Qinqin; Li, Yuandong; Song, Shaozhen

    2017-06-01

    Challenge persists in the field of optical coherence tomography (OCT) when it is required to quantify capillary blood flow within tissue beds in vivo. We propose a useful approach to statistically estimate the mean capillary flow velocity using a model-based statistical method of eigendecomposition (ED) analysis of the complex OCT signals obtained with the OCT angiography (OCTA) scanning protocol. ED-based analysis is achieved by the covariance matrix of the ensemble complex OCT signals, upon which the eigenvalues and eigenvectors that represent the subsets of the signal makeup are calculated. From this analysis, the signals due to moving particles can be isolated by employing an adaptive regression filter to remove the eigencomponents that represent static tissue signals. The mean frequency (MF) of moving particles can be estimated by the first lag-one autocorrelation of the corresponding eigenvectors. Three important parameters are introduced, including the blood flow signal power representing the presence of blood flow (i.e., OCTA signals), the MF indicating the mean velocity of blood flow, and the frequency bandwidth describing the temporal flow heterogeneity within a scanned tissue volume. The proposed approach is tested using scattering phantoms, in which microfluidic channels are used to simulate the functional capillary vessels that are perfused with the scattering intralipid solution. The results indicate a linear relationship between the MF and mean flow velocity. In vivo animal experiments are also conducted by imaging mouse brain with distal middle cerebral artery ligation to test the capability of the method to image the changes in capillary flows in response to an ischemic insult, demonstrating the practical usefulness of the proposed method for providing important quantifiable information about capillary tissue beds in the investigations of neurological conditions in vivo.

  18. Development and study of a heat pipe with dielectric properties

    NASA Astrophysics Data System (ADS)

    Semena, M. G.; Gershuni, A. N.; Chepurnoi, A. B.

    Requirements for the structural elements of heat pipes with dielectric properties are examined. To obtain information necessary for the thermal analysis of heat pipes, a study is made of the capillary-transport characteristics of a dielectric capillary structure consisting of quartz fibers; the capillary pressure and the liquid penetration coefficient are determined. The results of the study are used to develop dielectric heat pipes for the cooling of a vacuum electronic instrument. Experimentally determined characteristics of the heat pipes are presented.

  19. S-Adenosylhomocysteine Assay in the Urine by Capillary Electrophoresis.

    PubMed

    Luzyanin, B P; Ivanov, A V; Viryus, E D; Kubatiev, A A

    2015-08-01

    We present a simple and effective method for measuring urine S-adenosylhomocysteine by capillary electrophoresis without using modifiers. The detection threshold of the method is 0.1 μM S-adenosylhomocysteine, the time of analysis 13 min, reproducibility at physiological concentrations within 4%.

  20. Method and apparatus for automated processing and aliquoting of whole blood samples for analysis in a centrifugal fast analyzer

    DOEpatents

    Burtis, C.A.; Johnson, W.F.; Walker, W.A.

    1985-08-05

    A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises: (1) a whole blood sample disc; (2) a serum sample disc; (3) a sample preparation rotor; and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analyticaly rotor for conventional methods. 5 figs.

  1. Finding the Bio in Biobased Products: Electrophoretic Identification of Wheat Proteins in Processed Products

    USDA-ARS?s Scientific Manuscript database

    Verification of the bio-content in bio-based or green products identifies genuine products, exposes counterfeit copies, supports or refutes content claims and ensures consumer confidence. When the bio-content includes protein, elemental nitrogen analysis is insufficient for verification since non-pr...

  2. Genetic structure of populations and differentiation in forest trees

    Treesearch

    Raymond P. Guries; F. Thomas Ledig

    1981-01-01

    Electrophoretic techniques permit population biologists to analyze genetic structure of natural populations by using large numbers of allozyme loci. Several methods of analysis have been applied to allozyme data, including chi-square contingency tests, F-statistics, and genetic distance. This paper compares such statistics for pitch pine (Pinus rigida...

  3. An analysis of genetic architecture in populations of Ponderosa Pine

    Treesearch

    Yan B. Linhart; Jeffry B. Mitton; Kareen B. Sturgeon; Martha L. Davis

    1981-01-01

    Patterns of genetic variation were studied in three populations of ponderosa pine in Colorado by using electrophoretically variable protein loci. Significant genetic differences were found between separate clusters of trees and between age classes within populations. In addition, data indicate that differential cone production and differential animal damage have...

  4. Acoustic cavitation of individual ultrasound contrast agent microbubbles confined in capillaries

    NASA Astrophysics Data System (ADS)

    Almaqwashi, Ali; McIntyre, David; Ammi, Azzdine

    2011-10-01

    Ultrasound targeted therapies mainly rely on the inertial cavitation of ultrasound contrast agent (UCA) microbubbles. Our objective is to determine the cavitation acoustic pressure threshold for the destruction of UCA microbubbles inside cellulose capillaries. Acoustic emission from individual Optison microbubbles confined inside a 200-μm diameter capillary was detected using a passive cavitation detection system. Excitation signals from a 2.25 MHz transmitter were applied to the microbubbles while their acoustic emission was detected by a broadband 15 MHz receiver. Time traces were recorded (100 MHz sampling, 12- bit), and frequency-domain analysis of the received signals was performed to characterize microbubble cavitation. The cavitation acoustic pressure threshold was found to be 1 MPa inside the capillary in comparison with ˜0.7 MPa previously reported for unconfined UCA microbubbles. This work provides a clearer understanding of the role of ultrasound contrast agent dynamics inside a capillary.

  5. Optimization of gas-filled quartz capillary discharge waveguide for high-energy laser wakefield acceleration

    NASA Astrophysics Data System (ADS)

    Qin, Zhiyong; Li, Wentao; Liu, Jiansheng; Liu, Jiaqi; Yu, Changhai; Wang, Wentao; Qi, Rong; Zhang, Zhijun; Fang, Ming; Feng, Ke; Wu, Ying; Ke, Lintong; Chen, Yu; Wang, Cheng; Li, Ruxin; Xu, Zhizhan

    2018-04-01

    A hydrogen-filled capillary discharge waveguide made of quartz is presented for high-energy laser wakefield acceleration (LWFA). The experimental parameters (discharge current and gas pressure) were optimized to mitigate ablation by a quantitative analysis of the ablation plasma density inside the hydrogen-filled quartz capillary. The ablation plasma density was obtained by combining a spectroscopic measurement method with a calibrated gas transducer. In order to obtain a controllable plasma density and mitigate the ablation as much as possible, the range of suitable parameters was investigated. The experimental results demonstrated that the ablation in the quartz capillary could be mitigated by increasing the gas pressure to ˜7.5-14.7 Torr and decreasing the discharge current to ˜70-100 A. These optimized parameters are promising for future high-energy LWFA experiments based on the quartz capillary discharge waveguide.

  6. Identification and quantitation of morphological cell types in electrophoretically separated human embryonic kidney cell cultures

    NASA Technical Reports Server (NTRS)

    Williams, K. B.; Kunze, M. E.; Todd, P. W.

    1985-01-01

    Four major cell types were identified by phase microscopy in early passage human embryonic kidney cell cultures. They are small and large epithelioid, domed, and fenestrated cells. Fibroblasts are also present in some explants. The percent of each cell type changes with passage number as any given culture grows. As a general rule, the fraction of small epithelioid cells increases, while the fraction of fenestrated cells, always small, decreases further. When fibroblasts are present, they always increase in percentage of the total cell population. Electrophoretic separation of early passage cells showed that the domed cells have the highest electrophoretic mobility, fibroblasts have an intermediate high mobility, small epithelioid cells have a low mobility, broadly distributed, and fenestrated cells have the lowest mobility. All cell types were broadly distributed among electrophoretic subfractions, which were never pure but only enriched with respect to a given cell type.

  7. Kidney cell electrophoresis, continuing task

    NASA Technical Reports Server (NTRS)

    Todd, P. W.

    1985-01-01

    Materials and procedures for microgravity electrophoresis of living human embryonic kidney cells were evaluated to provide ground support in the form of analytical cell electrophoresis and flow cytometry. Preflight culture media, electrophoresis buffer, fraction collection media, temperature profiles, and urokinase assay procedures were tested prior to flight. Electrophoretic mobility distributions of aliquots of the cell population to be fractionated in flight were obtained. Cells were prepared in suspension prior to flight in electrophoresis buffer and 10% calf serum. Electrophoretic separation proceeded in electrophoresis buffer without serum in the Continuous Flow Electrophoretic Separator, and fractions were collected into sample bags containing culture medium and concentrated serum. Fractions that yielded enough progeny cells were analyzed for morphology and electrophoretic mobility distributions. It is noted that the lowest mobility fraction studied produced higher mobility progeny while the other fractions produced progeny cells with mobilities related to the fractions from which they were collected.

  8. Electrophoretic study of the genome of human rotavirus from Maceió, Brazil.

    PubMed

    Houly, C A; Uchoa, M M; Zaidan, A M; Gomes-Neto, A; de-Oliveira, F M; Athayde, M A; Almeida, M F; Pereira, H G

    1986-01-01

    Rotaviruses were detected by enzyme immunoassay (EIA) in 53 (13.3%) of 397 fecal samples from children with acute gastroenteritis in the city of Maceió, Alagoas, Brazil. Polyacrylamide gel electrophoretic (PAGE) patterns characteristic of rotavirus double-stranded RNA were detected in 51 (96.2%) of the 53 EIA-positive samples. Of the RNA-positive samples, 1 (2%) was classified as subgroup 1 (short profile), 49 (96%) as subgroup 2 (long profile) and 1 (2%) could not be classified because of the absence of bands 10 and 11. The strains of subgroup 2 showed a great degree of electrophoretic heterogeneity and could be divided into several subcategories. Two samples showed splitting of one of the genome segments. PAGE, a very sensitive method capable of identifying rotavirus RNA genomes, has demonstrated that human rotaviruses detected in Maceió present many differences in RNA electrophoretic patterns.

  9. Electrophoretic separations on paper: Past, present, and future-A review.

    PubMed

    Nanthasurasak, Pavisara; Cabot, Joan Marc; See, Hong Heng; Guijt, Rosanne M; Breadmore, Michael C

    2017-09-08

    Point-of-collection (POC) devices aim for a fast, on-site detection for medical and environmental purposes. In this area, microfluidic Paper-based Analytical Devices (μPADs) have recently gained popularity because these are potentially cheap and environmentally friendly to produce, and easy to use. From an analytical perspective, paper is well known for its use as a substrate for chromatography, but less known for its use in electrophoretic separations. With the recent interest in μPADs, most applications are based on rather simple assays with relatively few applications incorporating an analytical separation. The focus of this review is on paper-based electrophoresis, originating with the key developments in the 1940s and 1950s as well as the recent developments of electrophoretic μPADs, and concluding with a critical discussion of the opportunities and challenges for electrophoretic μPADS in the future. Copyright © 2017. Published by Elsevier B.V.

  10. Molecular phylogeny of the hominoid primates as indicated by two-dimensional protein electrophoresis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goldman, D.; Giri, P.R.; O'Brien, J.O.

    1987-05-01

    A molecular phylogeny for the hominoid primates was constructed by using genetic distances from a survey of 383 radiolabeled fibroblast polypeptides resolved by two-dimensional electrophoresis (2DE). An internally consistent matrix of Nei genetic distances was generated on the basis of variants in electrophoretic position. The derived phylogenetic tree indicated a branching sequence, from oldest to most recent, of cercopithecoids (Macaca fascicularis), gibbon-siamang, orangutan, gorilla, and human-chimpanzee. A cladistic analysis of 240 electrophoretic characters that varied between ape species produced an identical tree. Genetic distance measures obtained by 2DE are largely consistent with those generated by other molecular procedures. In addition,more » the 2DE data set appears to resolve the human-chimpanzee-gorilla trichotomy in favor of a more recent association of chimpanzees and humans.« less

  11. Facile Growth of Cu2ZnSnS4 Thin-Film by One-Step Pulsed Hybrid Electrophoretic and Electroplating Deposition.

    PubMed

    Tsai, Hung-Wei; Chen, Chia-Wei; Thomas, Stuart R; Hsu, Cheng-Hung; Tsai, Wen-Chi; Chen, Yu-Ze; Wang, Yi-Chung; Wang, Zhiming M; Hong, Hwen-Fen; Chueh, Yu-Lun

    2016-02-23

    The use of costly and rare metals such as indium and gallium in Cu(In,Ga)Se2 (CIGS) based solar cells has motivated research into the use of Cu2ZnSnS4 (CZTS) as a suitable replacement due to its non-toxicity, abundance of compositional elements and excellent optical properties (1.5 eV direct band gap and absorption coefficient of ~10(4) cm(-1)). In this study, we demonstrate a one-step pulsed hybrid electrodeposition method (PHED), which combines electrophoretic and electroplating deposition to deposit uniform CZTS thin-films. Through careful analysis and optimization, we are able to demonstrate CZTS solar cells with the VOC, JSC, FF and η of 350 mV, 3.90 mA/cm(2), 0.43 and 0.59%, respectively.

  12. Multicentric epidemiological study of Aspergillus fumigatus isolates by multilocus enzyme electrophoresis.

    PubMed Central

    Rodriguez, E; De Meeüs, T; Mallie, M; Renaud, F; Symoens, F; Mondon, P; Piens, M A; Lebeau, B; Viviani, M A; Grillot, R; Nolard, N; Chapuis, F; Tortorano, A M; Bastide, J M

    1996-01-01

    The genotypes of 63 isolates of Aspergillus fumigatus obtained from three hospitals in different geographical areas and of eight culture collection strains were determined by multilocus enzyme electrophoresis. Twelve of the 17 enzymatic loci studied were polymorphic, giving rise to 48 different electrophoretic types. The existence of fixed multilocus genotypes, significant heterozygote deficits and excesses at the different loci, and linkage disequilibria within subpopulations strongly suggests a clonal reproduction mode for A. fumigatus. Numerical analysis of the comparison and disposition of the different electrophoretic types demonstrates a significant genetic differentiation between the three sampling sites. However, no correlation could be found between geographical distances and genetic differentiation. On account of the multiple discriminatory markers, multilocus enzyme electrophoresis typing seems to be a very powerful tool for epidemiological and reproductive mode studies of A. fumigatus. PMID:8880520

  13. Identification of capillary rarefaction using intracoronary wave intensity analysis with resultant prognostic implications for cardiac allograft patients.

    PubMed

    Broyd, Christopher J; Hernández-Pérez, Francisco; Segovia, Javier; Echavarría-Pinto, Mauro; Quirós-Carretero, Alicia; Salas, Clara; Gonzalo, Nieves; Jiménez-Quevedo, Pilar; Nombela-Franco, Luis; Salinas, Pablo; Núñez-Gil, Ivan; Del Trigo, Maria; Goicolea, Javier; Alonso-Pulpón, Luis; Fernández-Ortiz, Antonio; Parker, Kim; Hughes, Alun; Mayet, Jamil; Davies, Justin; Escaned, Javier

    2018-05-21

    Techniques for identifying specific microcirculatory structural changes are desirable. As such, capillary rarefaction constitutes one of the earliest changes of cardiac allograft vasculopathy (CAV) in cardiac allograft recipients, but its identification with coronary flow reserve (CFR) or intracoronary resistance measurements is hampered because of non-selective interrogation of the capillary bed. We therefore investigated the potential of wave intensity analysis (WIA) to assess capillary rarefaction and thereby predict CAV. Fifty-two allograft patients with unobstructed coronary arteries and normal left ventricular (LV) function were assessed. Adequate aortic pressure and left anterior descending artery flow measurements at rest and with intracoronary adenosine were obtained in 46 of which 2 were lost to follow-up. In a subgroup of 15 patients, simultaneous RV biopsies were obtained and analysed for capillary density. Patients were followed up with 1-3 yearly screening angiography. A significant relationship with capillary density was noted with CFR (r = 0.52, P = 0.048) and the backward decompression wave (BDW) (r = -0.65, P < 0.01). Over a mean follow-up of 9.3 ± 5.2 years patients with a smaller BDW had an increased risk of developing angiographic CAV (hazard ratio 2.89, 95% CI 1.12-7.39; P = 0.03). Additionally, the index BDW was lower in those who went on to have a clinical CAV-events (P = 0.04) as well as more severe disease (P = 0.01). Within cardiac transplant patients, WIA is able to quantify the earliest histological changes of CAV and can predict clinical and angiographic outcomes. This proof-of-concept for WIA also lends weight to its use in the assessment of other disease processes in which capillary rarefaction is involved.

  14. Cutaneous vascular anomalies associated with neural tube defects: nomenclature and pathology revisited.

    PubMed

    Maugans, Todd; Sheridan, Rachel M; Adams, Denise; Gupta, Anita

    2011-07-01

    Lumbosacral cutaneous vascular anomalies associated with neural tube defects are frequently described in the literature as "hemangiomas." The classification system for pediatric vascular anomalies developed by the International Society for the Study of Vascular Anomalies provides a framework to accurately diagnose these lesions. To apply this classification to vascular cutaneous anomalies overlying myelodysplasias. A retrospective analysis of patients with neural tube defects and lumbosacral cutaneous vascular lesions was performed. All eligible patients had detailed histopathologic analysis of skin and spinal cord/placode lesions. Clinical and radiologic features were analyzed. Conventional histology and GLUT-1 immunostaining were performed to differentiate infantile capillary hemangiomas from capillary vascular malformations. Ten cases with cutaneous lesions associated with neural tube defects were reviewed. Five lesions were diagnosed as infantile capillary hemangiomas based upon histology and positive GLUT-1 endothelial reactivity. These lesions had a strong association with dermal sinus tracts. No reoperations were required for residual intraspinal vascular lesions, and overlying cutaneous vascular anomalies involuted with time. The remaining 5 lesions were diagnosed as capillary malformations. These occurred with both open and closed neural tube defects, did not involute, and demonstrated enlargement and darkening due to vascular congestion. The International Society for the Study of Vascular Anomalies scheme should be used to describe the cutaneous vascular lesions associated with neural tube defects: infantile capillary hemangiomas and capillary malformations. We advocate that these lesions be described as "vascular anomalies" or "stains" pending accurate diagnosis by clinical, histological, and immunohistochemical evaluations.

  15. Confocal laser-induced fluorescence detector for narrow capillary system with yoctomole limit of detection.

    PubMed

    Weaver, Mitchell T; Lynch, Kyle B; Zhu, Zaifang; Chen, Huang; Lu, Joann J; Pu, Qiaosheng; Liu, Shaorong

    2017-04-01

    Laser-induced fluorescence (LIF) detectors for low-micrometer and sub-micrometer capillary on-column detection are not commercially available. In this paper, we describe in details how to construct a confocal LIF detector to address this issue. We characterize the detector by determining its limit of detection (LOD), linear dynamic range (LDR) and background signal drift; a very low LOD (~70 fluorescein molecules or 12 yoctomole fluorescein), a wide LDR (greater than 3 orders of magnitude) and a small background signal drift (~1.2-fold of the root mean square noise) are obtained. For detecting analytes inside a low-micrometer and sub-micrometer capillary, proper alignment is essential. We present a simple protocol to align the capillary with the optical system and use the position-lock capability of a translation stage to fix the capillary in position during the experiment. To demonstrate the feasibility of using this detector for narrow capillary systems, we build a 2-μm-i.d. capillary flow injection analysis (FIA) system using the newly developed LIF prototype as a detector and obtain an FIA LOD of 14 zeptomole fluorescein. We also separate a DNA ladder sample by bare narrow capillary - hydrodynamic chromatography and use the LIF prototype to monitor the resolved DNA fragments. We obtain not only well-resolved peaks but also the quantitative information of all DNA fragments. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Apparent dynamic contact angle of an advancing gas--liquid meniscus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalliadasis, S.; Chang, H.

    1994-01-01

    The steady motion of an advancing meniscus in a gas-filled capillary tube involves a delicate balance of capillary, viscous, and intermolecular forces. The limit of small capillary numbers Ca (dimensionless speeds) is analyzed here with a matched asymptotic analysis that links the outer capillary region to the precursor film in front of the meniscus through a lubricating film. The meniscus shape in the outer region is constructed and the apparent dynamic contact angle [Theta] that the meniscus forms with the solid surface is derived as a function of the capillary number, the capillary radius, and the Hamaker's constant for intermolecularmore » forces, under conditions of weak gas--solid interaction, which lead to fast spreading of the precursor film and weak intermolecular forces relative to viscous forces within the lubricating film. The dependence on intermolecular forces is very weak and the contact angle expression has a tight upper bound tan [Theta]=7.48 Ca[sup 1/3] for thick films, which is independent of the Hamaker constant. This upper bound is in very good agreement with existing experimental data for wetting fluids in any capillary and for partially wetting fluids in a prewetted capillary. Significant correction to the Ca[sup 1/3] dependence occurs only at very low Ca, where the intermolecular forces become more important and tan [Theta] diverges slightly from the above asymptotic behavior toward lower values.« less

  17. Theoretical and experimental separation dynamics in capillary zone electrophoresis

    NASA Technical Reports Server (NTRS)

    Thormann, Wolfgang; Michaud, Jon-Pierre; Mosher, Richard A.

    1986-01-01

    The mathematical model of Bier et al. (1983) is used in a computer aided analysis of the conditions in capillary zone electrophoresis (ZE) under which sample zones migrate noninteractively with the carrier electrolyte. The monitoring of sample zones with a capillary analyzer that features both on-line conductivity and UV detection at the end of the separation trough is discussed. Data from a ZE analysis of a 5-component mixture are presented, and it is noted that all five components can be monitored via their conductivity change if enough sample is present. It is suggested from the results that the concentration ratio of background buffer to sample should be a minimum of 100:1 to effectively apply the plate concept to ZE.

  18. Analysis of flow dynamics through small diameter gas sampling systems

    NASA Technical Reports Server (NTRS)

    Brown, K. G.

    1984-01-01

    The removal of gas material through a capillary opening in a surface is analyzed. The gas, from which the sample is removed, is moving past the surface at supersonic velocities. A variety of possible conditions of temperature, pressure and composition are discussed in an effort to emulate conditions that might be found at the surface of a vehicle traversing the altitude range 100-50 km, or might exist at the surface of a model in the stream of a high enthalpy wind tunnel. Aspects discussed include: (1) the throughput of the capillary for conditions of different lengths and different L/a (length/radius) ratios; (2) the total throughput when the surface in question contains many hundreds of these capillaries; (3) the effect of the capillaries upon the composition of the analyzed gas; (4) the effect of the capillary or capillaries upon the gas stream itself; and (5) the implications of the calculations upon the possible implementation of this type of device as an inlet for a mass spectrometer to be developed for analyzing the upper atmosphere.

  19. Capillary zone electrophoresis for analysis of complex proteomes using an electrokinetically pumped sheath flow nanospray interface

    PubMed Central

    Sun, Liangliang; Zhu, Guijie; Yan, Xiaojing; Champion, Mathew M.

    2014-01-01

    The vast majority of proteomic studies employ reversed-phase high-performance liquid chromatography coupled with tandem mass spectrometry for analysis of the tryptic digest of a cellular lysate. This technology is quite mature, and typically provides identification of hundreds to thousands of peptides, which is used to infer the identity of hundreds to thousands of proteins. These approaches usually require milligrams to micrograms of starting material. Capillary zone electrophoresis provides an interesting alternative separation method based on a different separation mechanism than HPLC. Capillary electrophoresis received some attention for protein analysis beginning 25 years ago. Those efforts stalled because of the limited performance of the electrospray interfaces and the limited speed and sensitivity of mass spectrometers of that era. This review considers a new electrospray interface design coupled with Orbitrap Velos and linear Q-trap mass spectrometers. Capillary zone electrophoresis coupled with this interface and these detectors provides single shot detection of >1,250 peptides from an E. coli digest in less than one hour, identification of nearly 5,000 peptides from analysis of seven fractions produced by solid-phase extraction of the E. coli digest in a six hour total analysis time, low attomole detection limits for peptides generated from standard proteins, and high zeptomole detection limits for selected ion monitoring of peptides. Incorporation of an integrated on-line immobilized trypsin microreactor allows digestion and analysis of picogram amounts of a complex eukaryotic proteome. PMID:24277677

  20. Nucleation theory - Is replacement free energy needed?. [error analysis of capillary approximation

    NASA Technical Reports Server (NTRS)

    Doremus, R. H.

    1982-01-01

    It has been suggested that the classical theory of nucleation of liquid from its vapor as developed by Volmer and Weber (1926) needs modification with a factor referred to as the replacement free energy and that the capillary approximation underlying the classical theory is in error. Here, the classical nucleation equation is derived from fluctuation theory, Gibb's result for the reversible work to form a critical nucleus, and the rate of collision of gas molecules with a surface. The capillary approximation is not used in the derivation. The chemical potential of small drops is then considered, and it is shown that the capillary approximation can be derived from thermodynamic equations. The results show that no corrections to Volmer's equation are needed.

Top