Analysis of Alkaloids from Physalis peruviana by Capillary GC, Capillary GC-MS, and GC-FTIR.
Kubwabo, C; Rollmann, B; Tilquin, B
1993-04-01
The alkaloid composition of the aerial parts and roots of PHYSALIS PERUVIANA was analysed by capillary GC (GC (2)), GC (2)-MS and GC (2)-FTIR. Eight alkaloids were identified, three of those alkaloids are 3beta-acetoxytropane and two N-methylpyrrolidinylhygrine isomers, which were not previously found in the genus PHYSALIS. A reproduction of the identification of alkaloids detected in the plant by the use of retention indices has been proposed.
Automated two-dimensional interface for capillary gas chromatography
Strunk, M.R.; Bechtold, W.E.
1996-02-20
A multidimensional gas chromatograph (GC) system is disclosed which has wide bore capillary and narrow bore capillary GC columns in series and has a novel system interface. Heart cuts from a high flow rate sample, separated by a wide bore GC column, are collected and directed to a narrow bore GC column with carrier gas injected at a lower flow compatible with a mass spectrometer. A bimodal six-way valve is connected with the wide bore GC column outlet and a bimodal four-way valve is connected with the narrow bore GC column inlet. A trapping and retaining circuit with a cold trap is connected with the six-way valve and a transfer circuit interconnects the two valves. The six-way valve is manipulated between first and second mode positions to collect analyte, and the four-way valve is manipulated between third and fourth mode positions to allow carrier gas to sweep analyte from a deactivated cold trap, through the transfer circuit, and then to the narrow bore GC capillary column for separation and subsequent analysis by a mass spectrometer. Rotary valves have substantially the same bore width as their associated columns to minimize flow irregularities and resulting sample peak deterioration. The rotary valves are heated separately from the GC columns to avoid temperature lag and resulting sample deterioration. 3 figs.
Automated two-dimensional interface for capillary gas chromatography
Strunk, Michael R.; Bechtold, William E.
1996-02-20
A multidimensional gas chromatograph (GC) system having wide bore capillary and narrow bore capillary GC columns in series and having a novel system interface. Heart cuts from a high flow rate sample, separated by a wide bore GC column, are collected and directed to a narrow bore GC column with carrier gas injected at a lower flow compatible with a mass spectrometer. A bimodal six-way valve is connected with the wide bore GC column outlet and a bimodal four-way valve is connected with the narrow bore GC column inlet. A trapping and retaining circuit with a cold trap is connected with the six-way valve and a transfer circuit interconnects the two valves. The six-way valve is manipulated between first and second mode positions to collect analyte, and the four-way valve is manipulated between third and fourth mode positions to allow carrier gas to sweep analyte from a deactivated cold trap, through the transfer circuit, and then to the narrow bore GC capillary column for separation and subsequent analysis by a mass spectrometer. Rotary valves have substantially the same bore width as their associated columns to minimize flow irregularities and resulting sample peak deterioration. The rotary valves are heated separately from the GC columns to avoid temperature lag and resulting sample deterioration.
COMPARATIVE EVALUATION OF GC/MS (GAS CHROMATOGRAPHY/MASS SPECTROMETRY) DATA ANALYSIS PROCESSING
Mass spectra obtained by fused silica capillary gas chromatography/mass spectrometry/data system (GC/MS/DS) analysis of mixtures of organic chemicals adsorbed on Tenax GC cartridges was subjected to manual and automated interpretative techniques. Synthetic mixtures (85 chemicals ...
Trace-Level Automated Mercury Speciation Analysis
Taylor, Vivien F.; Carter, Annie; Davies, Colin; Jackson, Brian P.
2011-01-01
An automated system for methyl Hg analysis by purge and trap gas chromatography (GC) was evaluated, with comparison of several different instrument configurations including chromatography columns (packed column or capillary), detector (atomic fluorescence, AFS, or inductively coupled plasma mass spectrometry, ICP-MS, using quadrupole and sector field ICP- MS instruments). Method detection limits (MDL) of 0.042 pg and 0.030 pg for CH3Hg+ were achieved with the automated Hg analysis system configured with AFS and ICPMS detection, respectively. Capillary GC with temperature programming was effective in improving resolution and decreasing retention times of heavier Hg species (in this case C3H7Hg+) although carryover between samples was increased. With capillary GC, the MDL for CH3Hg+ was 0.25 pg for AFS detection and 0.060 pg for ICP-MS detection. The automated system was demonstrated to have high throughput (72 samples analyzed in 8 hours) requiring considerably less analyst time than the manual method for methyl mercury analysis described in EPA 1630. PMID:21572543
Tranchida, Peter Quinto; Presti, Maria Lo; Costa, Rosaria; Dugo, Paola; Dugo, Giovanni; Mondello, Luigi
2006-01-20
The advantages of using a narrow-bore column in headspace solid-phase microextraction-gas chromatographic (HS-SPME-GC) analysis are investigated. An automated rapid HS-SPME-GC method for the determination of volatile compounds in a complex sample (bergamot essential oil) was developed. A low-capacity (7 microm) SPME fibre was employed, enabling a short equilibration time (15 min). The absorbed volatile compounds were then separated in 12.5 min on a 10 m x 0.1 mm I.D. capillary. The fast GC method was characterized by relatively moderate GC parameters (head pressure: 173 kPa; temperature program rate: 12 degrees C/min). The employment of the low-capacity fibre also suited the reduced sample capacity of the capillary employed, hence column overloading was avoided. Analytical repeatibility was determined in terms of retention times (maximum RSD: 0.32%) and peak areas (maximum RSD: 9.80%). The results obtained were compared to those derived from a conventional HS-SPME-GC (a 30 microm SPME fibre and 0.25 mm I.D. capillary were used) application on the same sample. In this respect, a great reduction of analytical time was obtained both with regard to the conventional SPME equilibration and GC run times, which both required 50 min. Peak resolution was altogether comparable in both applications. Although a slight loss in terms of sensitivity was observed in the rapid approach (generally within the 25-50% range), this did not impair the detection of all peaks of interest. Finally, the selectivities of the 30 and 7 microm fibres were evaluated and, as expected, these were in good agreement.
Urakami, K; Saito, Y; Fujiwara, Y; Watanabe, C; Umemoto, K; Godo, M; Hashimoto, K
2000-12-01
Thermal desorption (TD) techniques followed by capillary GC/MS were applied for the analysis of residual solvents in bulk pharmaceuticals. Solvents desorbed from samples by heating were cryofocused at the head of a capillary column prior to GC/MS analysis. This method requires a very small amount of sample and no sample pretreatment. Desorption temperature was set at the point about 20 degrees C higher than the melting point of each sample individually. The relative standard deviations of this method tested by performing six consecutive analyses of 8 different samples were 1.1 to 3.1%, and analytical results of residual solvents were in agreement with those obtained by direct injection of N,N-dimethylformamide solution of the samples into the GC. This novel TD/GC/MS method was demonstrated to be very useful for the identification and quantification of residual solvents in bulk pharmaceuticals.
Analysis of Endocrine Disrupting Pesticides by Capillary GC with Mass Spectrometric Detection
Matisová, Eva; Hrouzková, Svetlana
2012-01-01
Endocrine disrupting chemicals, among them many pesticides, alter the normal functioning of the endocrine system of both wildlife and humans at very low concentration levels. Therefore, the importance of method development for their analysis in food and the environment is increasing. This also covers contributions in the field of ultra-trace analysis of multicomponent mixtures of organic pollutants in complex matrices. With this fact conventional capillary gas chromatography (CGC) and fast CGC with mass spectrometric detection (MS) has acquired a real importance in the analysis of endocrine disrupting pesticide (EDP) residues. This paper provides an overview of GC methods, including sample preparation steps, for analysis of EDPs in a variety of matrices at ultra-trace concentration levels. Emphasis is put on separation method, mode of MS detection and ionization and obtained limits of detection and quantification. Analysis time is one of the most important aspects that should be considered in the choice of analytical methods for routine analysis. Therefore, the benefits of developed fast GC methods are important. PMID:23202677
Hayes, M A
1988-04-01
Gas chromatography (GC) is the most widely used analytical technique in the food and beverage industry. This paper addresses the problems of sample preparation and system maintenance to ensure the most sensitive, durable, and efficient results for trace analysis by GC in this industry.
The multi-mode modulator: A versatile fluidic device for two-dimensional gas chromatography.
Seeley, John V; Schimmel, Nicolaas E; Seeley, Stacy K
2018-02-09
A fluidic device called the multi-mode modulator (MMM) has been developed for use as a comprehensive two-dimensional gas chromatography (GC x GC) modulator. The MMM can be employed in a wide range of capacities including as a traditional heart-cutting device, a low duty cycle GC x GC modulator, and a full transfer GC x GC modulator. The MMM is capable of producing narrow component pulses (widths <50ms) while operating at flows compatible with high resolution chromatography. The sample path of modulated components is confined to the interior of a joining capillary. The joining capillary dimensions and the position of the columns within the joining capillary can be optimized for the selected modulation mode. Furthermore, the joining capillary can be replaced easily and inexpensively if it becomes fouled due to sample matrix components or column bleed. The principles of operation of the MMM are described and its efficacy is demonstrated as a heart-cutting device and as a GC x GC modulator. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Gonzalez, Marianne; Quinn, Jacqueline; Captain, Janine; Santiago-Bond, Josephine; Starr, Stanley
2015-01-01
The Resource Prospector (RP) mission with the Regolith and Environment Science and Oxygen Lunar Volatile Extraction (RESOLVE) payload aims to show the presence of water in lunar regolith, and establish a proving ground for NASAs mission to Mars. One of the analysis is performed by the Lunar Advanced Volatiles Analysis (LAVA) subsystem, which consists of a fluid network that facilitates the transport of volatile samples to a gas chromatograph and mass spectrometer (GC-MS) instrument. The understanding of fluid dynamics directed from the GC to the MS is important due to the influence of flow rates and pressures that affect the accuracy of and prevent the damage to the overall GC-MS instrument. The micro-scale capillary fluid network within the GC alone has various lengths and inner-diameters; therefore, determination of pressure differentials and flow rates are difficult to model computationally, with additional complexity from the vacuum conditions in space and lack of a lunar atmosphere. A series of tests were performed on an experimental set-up of the system where the inner diameters of the GC transfer line connecting to the MS were varied. The effect on chromatography readings were also studied by applying these lines onto a GC instrument. It was found that a smaller inner diameter transfer line resulted in a lower flow rate, as well as a lower pressure differential across the thermal conductivity detector (TCD) unit of the GC and a negligible pressure drop across the mock-up capillary column. The chromatography was affected with longer retention times and broader peak integrations. It was concluded that a 0.050 mm inner diameter line still proved most suitable for the systems flow rate preferences. In addition, it was evident that this small transfer line portrayed some expense to GC signal characteristics and the wait time for steady-state operation.
On-line Analysis of Catalytic Reaction Products Using a High-Pressure Tandem Micro-reactor GC/MS.
Watanabe, Atsushi; Kim, Young-Min; Hosaka, Akihiko; Watanabe, Chuichi; Teramae, Norio; Ohtani, Hajime; Kim, Seungdo; Park, Young-Kwon; Wang, Kaige; Freeman, Robert R
2017-01-01
When a GC/MS system is coupled with a pressurized reactor, the separation efficiency and the retention time are directly affected by the reactor pressure. To keep the GC column flow rate constant irrespective of the reaction pressure, a restrictor capillary tube and an open split interface are attached between the GC injection port and the head of a GC separation column. The capability of the attached modules is demonstrated for the on-line GC/MS analysis of catalytic reaction products of a bio-oil model sample (guaiacol), produced under a pressure of 1 to 3 MPa.
Fang, Ching; Chung, Yu-Lin; Liu, Ju-Tsung; Lin, Cheng-Huang
2002-02-18
Because of the increasing use of 3,4-methylenedioxymethamphetamine (3,4-MDMA), a rapid and sensitive analytical technique is required for its detection and determination. Using nonaqueous capillary electrophoresis/fluorescence spectroscopy (NACE/FS) detection, it is possible to determine this drug at the level 0.5 ppm without any pre-treatment in less than 5 min. After liquid-liquid extraction, the sample can be condensed and a detection limit of 3,4-MDMA in urine of 50 ppb (S/N = 3) can be achieved. The precision of the method was evaluated by measuring the repeatability and intermediate precision of migration time and the corrected peak height by comparison with a 3,4-MDMA-D5 internal standard. With the conventional GC/MS method, it is necessary to derivatize the 3,4-MDMA before injection and the GC migration time also is in excess of 20 min. Therefore, NACE/FS represents a good complementary method to GC/MS for use in forensic analysis.
NASA Astrophysics Data System (ADS)
Qian, Michael C.
Gas chromatography (GC) has many applications in the analysis of food products. GC has been used for the determination of fatty acids, triglycerides, cholesterol, gases, water, alcohols, pesticides, flavor compounds, and many more. While GC has been used for other food components such as sugars, oligosaccharides, amino acids, peptides, and vitamins, these substances are more suited to analysis by high performance liquid chromatography. GC is ideally suited to the analysis of volatile substances that are thermally stable. Substances such as pesticides and flavor compounds that meet these criteria can be isolated from a food and directly injected into the GC. For compounds that are thermally unstable, too low in volatility, or yield poor chromatographic separation due to polarity, a derivatization step must be done before GC analysis. The two parts of the experiment described here include the analysis of alcohols that requires no derivatization step, and the analysis of fatty acids which requires derivatization. The experiments specify the use of capillary columns, but the first experiment includes conditions for a packed column.
Mimura, Mayumi; Nakashima, Harunobu; Yoshida, Jin; Yoshida, Toshiaki; Kawakami, Tsuyoshi; Isama, Kazuo
2014-01-01
The official analytical method for tris(2,3-dibromopropyl)phosphate (TDBPP), which is banned from use in textile products by the "Act on Control of Household Products Containing Harmful Substances", requires revision. This study examined an analytical method for TDBPP by GC/MS using a capillary column. Thermal decomposition of TDBPP was observed by GC/MS measurement using capillary column, unlike in the case of gas chromatography/flame photometric detector (GC/FPD) measurement based on a direct injection method using a capillary megabore column. A quadratic curve, Y=2572X(1.416), was obtained for the calibration curve of GC/FPD in the concentration range 2.0-100 μg/mL. The detection limit was 1.0 μg/mL under S/N=3. The reproducibility for repetitive injections was satisfactory. A pretreatment method was established using methanol extraction, followed by liquid-liquid partition and purification with a florisil cartridge column. The recovery rate of this method was ~100%. TDBPP was not detected in any of the five commercial products that this study analyzed. To understand the cause of TDBPP decomposition during GC/MS (electron ionization; EI) measurement using capillary column, GC/MS (chemical ionization; CI), GC/FPD, and gas chromatography/flame ionization detector (GC/FID) measurements were conducted. It was suggested that TDBPP might thermally decompose both during GC injection, especially through a splitless injection method, and in the column or ion sources. To attempt GC/MS measurement, an injection part comprising quartz liner was used and the column length was halved (15 m); thus, only one peak could be obtained.
Penning, Holger; Elsner, Martin
2007-11-01
Potentially, compound-specific isotope analysis may provide unique information on source and fate of pesticides in natural systems. Yet for isotope analysis, LC-based methods that are based on the use of organic solvents often cannot be used and GC-based analysis is frequently not possible due to thermolability of the analyte. A typical example of a compound with such properties is isoproturon (3-(4-isopropylphenyl)-1,1-dimethylurea), belonging to the worldwide extensively used phenylurea herbicides. To make isoproturon accessible to carbon and nitrogen isotope analysis, we developed a GC-based method during which isoproturon was quantitatively fragmented to dimethylamine and 4-isopropylphenylisocyanate. Fragmentation occurred only partially in the injector but was mainly achieved on a heated capillary column. The fragments were then chromatographically separated and individually measured by isotope ratio mass spectrometry. The reliability of the method was tested in hydrolysis experiments with three isotopically different batches of isoproturon. For all three products, the same isotope fractionation factors were observed during conversion and the difference in isotope composition between the batches was preserved. This study demonstrates that fragmentation of phenylurea herbicides does not only make them accessible to isotope analysis but even enables determination of intramolecular isotope fractionation.
Chai, X S; Schork, F J; DeCinque, Anthony
2005-04-08
This paper reports an improved headspace gas chromatographic (GC) technique for determination of monomer solubilities in water. The method is based on a multiple headspace extraction GC technique developed previously [X.S. Chai, Q.X. Hou, F.J. Schork, J. Appl. Polym. Sci., in press], but with the major modification in the method calibration technique. As a result, only a few iterations of headspace extraction and GC measurement are required, which avoids the "exhaustive" headspace extraction, and thus the experimental time for each analysis. For highly insoluble monomers, effort must be made to minimize adsorption in the headspace sampling channel, transportation conduit and capillary column by using higher operating temperature and a short capillary column in the headspace sampler and GC system. For highly water soluble monomers, a new calibration method is proposed. The combinations of these technique modifications results in a method that is simple, rapid and automated. While the current focus of the authors is on the determination of monomer solubility in aqueous solutions, the method should be applicable to determination of solubility of any organic in water.
NASA Astrophysics Data System (ADS)
Galipo, Randolph C.; Canhoto, Alfredo J.; Walla, Michael D.; Morgan, Stephen L.
1999-02-01
A senior-level undergraduate laboratory experiment that demonstrates the use of solid-phase microextraction (SPME) and capillary gas chromatography-mass spectrometry (GC-MS) was developed for the identification of volatile compounds in consumer products. SPME minimizes sample preparation and concentrates volatile analytes in a solvent-free manner. Volatile flavor and fragrance compounds were extracted by SPME from the headspace of vials containing shampoos, chewing gums, and perfumes and analyzed by GC-MS. Headspace SPME was shown to be more sensitive than conventional headspace analysis of similar samples performed with an airtight syringe. Analysis times were less than 30 min, allowing multiple analyses to be performed in a typical laboratory class period.
Taylor, Carl; Lough, Fraser; Stanforth, Stephen P; Schwalbe, Edward C; Fowlis, Ian A; Dean, John R
2017-07-01
Listeria monocytogenes is a Gram-positive bacterium and an opportunistic food-borne pathogen which poses significant risk to the immune-compromised and pregnant due to the increased likelihood of acquiring infection and potential transmission of infection to the unborn child. Conventional methods of analysis suffer from either long turn-around times or lack the ability to discriminate between Listeria spp. reliably. This paper investigates an alternative method of detecting Listeria spp. using two novel enzyme substrates that liberate exogenous volatile organic compounds in the presence of α-mannosidase and D-alanyl aminopeptidase. The discriminating capabilities of this approach for identifying L. monocytogenes from other species of Listeria are investigated. The liberated volatile organic compounds (VOCs) are detected using an automated analytical technique based on static headspace-multi-capillary column-gas chromatography-ion mobility spectrometry (SHS-MCC-GC-IMS). The results obtained by SHS-MCC-GC-IMS are compared with those obtained by the more conventional analytical technique of headspace-solid phase microextraction-gas chromatography-mass spectrometry (HS-SPME-GC-MS). The results found that it was possible to differentiate between L. monocytogenes and L. ivanovii, based on their VOC response from α-mannosidase activity.
Ishii, A; Seno, H; Watanabe-Suzuki, K; Suzuki, O; Kumazawa, T
1998-11-15
Cyanide, one of the most important toxic substances, has been found measurable with high sensitivity by capillary gas chromatography (GC) with cryogenic oven trapping upon injection of headspace (HS) vapor samples. The entire amount of cyanide in the HS sample could be cryogenically trapped prior to on-line GC analysis. A 0.5-mL volume of blood in the presence or absence of cyanide and propionitrile (internal standard, IS) was added to a vial containing 0.25 mL of distilled water, 0.3 g of Na2-SO4, 0.2 mL of 50% H3PO4, and 0.1 g of ascorbic acid (when needed), and the mixture was heated at 70 degrees C for 15 min. A 5-mL volume of the HS vapor was introduced into a GC capillary column in the splitless mode at -30 degrees C oven temperature that was programmed up to 160 degrees C for GC analysis with nitrogen-phosphorus detection. A sharp peak was obtained for cyanide under the present conditions, and backgrounds were very clean. The extraction efficiencies of cyanide and IS were 2.89-3.22 (100 or 500 ng/mL) and 2.42%, respectively. The calibration curve showed good linearity in the range of 25-1000 ng/mL and the detection limit was approximately 2 ng/mL. The coefficients of intraday and interday variations were 2.9 and 11.8%, respectively. The mean blood cyanide level measured for actual fire victims was 687 +/- 597 ng/mL (mean +/- SD, n = 9). Endogenous blood cyanide concentration for healthy subjects was 8.41 +/- 3.09 ng/mL (mean +/- SD, n = 6).
Mondello, Luigi; Casillia, Alessandro; Tranchida, Peter Quinto; Dugo, Giovanni; Dugo, Paola
2005-03-04
Single column gas chromatography (GC) in combination with a flame ionization detector (FID) and/or a mass spectrometer is routinely employed in the determination of perfume profiles. The latter are to be considered medium to highly complex matrices and, as such, can only be partially separated even on long capillaries. Inevitably, several monodimensional peaks are the result of two or more overlapping components, often hindering reliable identification and quantitation. The present investigation is based on the use of a comprehensive GC (GC x GC) method, in vacuum outlet conditions, for the near to complete resolution of a complex perfume sample. A rapid scanning quadrupole mass spectrometry (qMS) system, employed for the assignment of GC x GC peaks, supplied high quality mass spectra. The validity of the three-dimensional (3D) GC x GC-qMS application was measured and compared to that of GC-qMS analysis on the same matrix. Peak identification, in all applications, was achieved through MS spectra library matching and the interactive use of linear retention indices (LRI).
The chromatographic and mass spectral characteristics of perfluorooctanesulfonate (PFOS) and three nitrogen-substituted perfluorooctanesulfonamides have been obtained. A methyl/phenol mixed phase fused silica capillary column was used for GC analysis, while a C18 reversed phase ...
Furlong, E.T.; Vaught, D.G.; Merten, L.M.; Foreman, W.T.; Gates, Paul M.
1996-01-01
A method for the determination of 79 semivolatile organic compounds (SOCs) and 4 surrogate compounds in soils and bottom sediment is described. The SOCs are extracted from bottom sediment by solvent extraction, followed by partial isolation using high-performance gel permeation chromatography (GPC). The SOCs then are qualitatively identified and quantitative concentrations determined by capillary-column gas chromatography/mass spectrometry (GC/MS). This method also is designed for an optional simultaneous isolation of polychlorinated biphenyls (PCBs) and organochlorine (OC) insecticides, including toxaphene. When OCs and PCBs are determined, an additional alumina- over-silica column chromatography step follows GPC cleanup, and quantitation is by dual capillary- column gas chromatography with electron-capture detection (GC/ECD). Bottom-sediment samples are centrifuged to remove excess water and extracted overnight with dichloromethane. The extract is concentrated, centrifuged, and then filtered through a 0.2-micrometer polytetrafluoro-ethylene syringe filter. Two aliquots of the sample extract then are quantitatively injected onto two polystyrene- divinylbenzene GPC columns connected in series. The SOCs are eluted with dichloromethane, a fraction containing the SOCs is collected, and some coextracted interferences, including elemental sulfur, are separated and discarded. The SOC-containing GPC fraction then is analyzed by GC/MS. When desired, a second aliquot from GPC is further processed for OCs and PCBs by combined alumina-over-silica column chromatography. The two fractions produced in this cleanup then are analyzed by GC/ECD. This report fully describes and is limited to the determination of SOCs by GC/MS.
Mondello, Luigi; Casilli, Alessandro; Tranchida, Peter Quinto; Dugo, Paola; Dugo, Giovanni
2003-11-26
Comprehensive gas chromatography (GC x GC) is an adequate methodology for the separation and identification of very complex samples. It is based on the coupling of two capillary columns that each give a different but substantial contribution to the unprecedented resolving power of this technique. The 2D space chromatograms that derive from GC x GC analysis have great potential for identification. This is due to the fact that the contour plot positions, pinpointed by two retention time coordinates, give characteristic patterns for specific families of compounds that can be mathematically translated. This investigation concerned the application of this principle to fatty acid methyl esters that were grouped on an equal double bond number basis. The ester samples were derived from various lipids and all underwent bidimensional analysis on two sets of columns. Peak attribution was supported by mass spectra, linear retention indices and information reported in the literature.
Yarasheski, Kevin E.; Smith, Kenneth; Rennie, Michael J.; Bier, Dennis M.
2014-01-01
The measurement of skeletal muscle protein fractional synthetic rate using an infusion of (1-13C)leucine and measuring the isotopic abundance of the tracer in skeletal muscle protein by preparative gas chromatography (GC)/ninhydrin isotope ratio mass spectrometry (IRMS) is laborious and subject to errors owing to contamination by 12C. The purpose of this study was to compare muscle (13C)leucine enrichment measured with the conventional preparative GC/ninhydrin IRMS approach to a new, continuous-flow technique using capillary GC/combustion IRMS. Quadriceps muscles were removed from four Sprague–Dawley rats after each was infused at a different rate with (1-13C)leucine for 6–8 h. Muscle leucine enrichment (at.% excess) measured by both methods differed by less than 4%, except at low (13C)leucine enrichments (<0.03 at.% excess). In addition, capillary GC/combustion IRMS was used to assess muscle (13C)leucine enrichment and fractional muscle protein synthesis rate in ten normal young men and women infused with (1,2-13C2)leucine for 12–14 h. This approach reduced the variability of the isotope abundance measure and gave estimates of muscle protein synthesis rate (0.050 ± 0.011% h−1 (mean ± SEM); range = 0.023–0.147% h−1) that agree with published values determined using the standard analytical approach. The measurement of (13C)leucine enrichment from skeletal muscle protein by capillary GC/combustion IRMS provides a simple, acceptable and practical alternative to preparative GC/ninhydrin IRMS. PMID:1420371
Chemical composition of the essential oil of Feronia elephantum Correa.
Pande, Chitra; Tewari, Geeta; Singh, Charu; Singh, Shalini; Padalia, R C
2010-11-01
The essential oil composition of Feronia elephantum Correa (family: Rutaceae) was examined by capillary gas chromatography (GC) and gas chromatography-mass spectroscopy (GC-MS). The analysis revealed the presence of 24 constituents, of which 18 constituents were identified. Trans-anethole (57.73%) and methyl chavicol (37.48%) were the major compounds, while cis-anethole, p-anisaldehyde, (E)-jasmone, methyl eugenol, β-caryophyllene, linalool and (E)-methyl isoeugenol were also present as the minor constituents.
Gas chromatographic separation of fatty acid methyl esters on weakly polar capillary columns.
Yamamoto, Kouhei; Kinoshita, Akemi; Shibahara, Akira
2008-02-22
It was found that weakly polar columns, routinely used in capillary GC for analyzing sterols, food additives, etc., can also be used for separating fatty acid methyl esters (FAMEs). On these columns, FAMEs elute in the order of their unsaturation. The equivalent chain-length value of methyl 22:6 is below 23.00. This means FAMEs within a carbon chain length, having up to six double bonds, elute before the next (one carbon longer) saturated FAME elutes. Peak identification is easy. Weakly polar columns are compatible in both GC and GC/MS systems.
Špiranec, Katarina; Chen, Wen; Werner, Franziska; Nikolaev, Viacheslav O; Naruke, Takashi; Koch, Franziska; Werner, Andrea; Eder-Negrin, Petra; Diéguez-Hurtado, Rodrigo; Adams, Ralf H; Baba, Hideo A; Schmidt, Hannes; Schuh, Kai; Skryabin, Boris V; Movahedi, Kiavash; Schweda, Frank; Kuhn, Michaela
2018-04-06
Background -Peripheral vascular resistance has a major impact on arterial blood pressure levels. Endothelial C-type natriuretic peptide (CNP) participates in the local regulation of vascular tone but the target cells remain controversial. The cGMP-producing guanylyl cyclase-B (GC-B) receptor for CNP is expressed in vascular smooth muscle cells (VSMC). However, whereas endothelial cell-specific CNP knockout mice are hypertensive, mice with deletion of GC-B in VSMC have unaltered blood pressure. Methods -We analyzed whether the vasodilating response to CNP changes along the vascular tree, i.e. whether the GC-B receptor is expressed in microvascular types of cells. Mice with a floxed GC-B ( Npr2 ) gene were interbred with Tie2-Cre or PDGF-Rβ-Cre ERT2 lines to develop mice lacking GC-B in endothelial cells or in precapillary arteriolar SMC and capillary pericytes. Intravital microscopy, (non)invasive hemodynamics, fluorescence energy transfer studies of pericyte's cAMP levels in situ and renal physiology were combined to dissect whether and how CNP/GC-B/cGMP signaling modulates microcirculatory tone and blood pressure. Results -Intravital microscopy studies revealed that the vasodilatatory effect of CNP increases towards small-diameter arterioles and capillaries. Consistently, CNP did not prevent endothelin-1-induced acute constrictions of proximal arterioles but fully reversed endothelin effects in precapillary arterioles and capillaries. Here, the GC-B receptor is expressed both in endothelial and mural cells, i.e. in pericytes. Notably, the vasodilatatory effects of CNP were preserved in mice with endothelial GC-B deletion but abolished in mice lacking GC-B in microcirculatory SMC and pericytes. CNP, via GC-B/cGMP signaling modulates two signaling cascades in pericytes: it activates cGMP-dependent protein kinase I to phosphorylate downstream targets such as the cytoskeleton-associated vasodilator activated phosphoprotein; and it inhibits phosphodiesterase 3A, thereby enhancing pericyte's cAMP levels. Ultimately these pathways prevent endothelin-induced increases of pericyte calcium levels and pericyte contraction. Mice with deletion of GC-B in microcirculatory SMC and pericytes have elevated peripheral resistance and chronic arterial hypertension without a change in renal function. Conclusions -Our studies indicate that endothelial CNP regulates distal arteriolar and capillary blood flow. CNP-induced GC-B/cGMP signaling in microvascular SMC and pericytes is essential for the maintenance of normal microvascular resistance and blood pressure.
Development of a screening method for the determination of forty-nine priority pollutants in soil
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kiang, P.H.T.
1985-01-01
An extraction procedure followed by capillary GC-MS analysis was used to determine soil pollutants. Dual pH solutions with methylene chloride were used as extraction solvent system. Both base/neutral and acidic fractions were analyzed on the same fused silica 30 meter SPB-1 (SE-30) column. A GC-FID with a 60 meter wide-bore SPB-1 glass capillary column was used for quantitative analysis due to its larger sample capacity and higher sensitivity. The precision and accuracy for 5.1 ppm (51 ..mu..g/10 g) concentration in zero soil was less than 25% RSD. A headspace technique was also developed for the determination of volatile compounds. Themore » same instrumental conditions and columns were used as in the extraction procedure. The precision and accuracy for 3 grams soil sample spiked with 5.1 ppm (52 ..mu..g/10 mL) pollutant mixture in a 20 mL vial was less than 3% RSD.« less
Properties of water as a novel stationary phase in capillary gas chromatography.
Gallant, Jonathan A; Thurbide, Kevin B
2014-09-12
A novel method of separation that uses water as a stationary phase in capillary gas chromatography (GC) is presented. Through applying a water phase to the interior walls of a stainless steel capillary, good separations were obtained for a large variety of analytes in this format. It was found that carrier gas humidification and backpressure were key factors in promoting stable operation over time at various temperatures. For example, with these measures in place, the retention time of an acetone test analyte was found to reduce by only 44s after 100min of operation at a column temperature of 100°C. In terms of efficiency, under optimum conditions the method produced about 20,000 plates for an acetone test analyte on a 250μm i.d.×30m column. Overall, retention on the stationary phase generally increased with analyte water solubility and polarity, but was relatively little correlated with analyte volatility. Conversely, non-polar analytes were essentially unretained in the system. These features were applied to the direct analysis of different polar analytes in both aqueous and organic samples. Results suggest that this approach could provide an interesting alternative tool in capillary GC separations. Copyright © 2014 Elsevier B.V. All rights reserved.
Maraschiello, C; García Regueiro, J A
1998-08-28
A procedure designed for the determination of retinol (vitamin A) and alpha-tocopherol (vitamin E) in poultry tissues has been developed. The procedure involves lipid extraction, saponification, solid-phase clean-up and capillary gas chromatography (cGC). Retinol and alpha-tocopherol were determined separately by cGC-flame ionisation detection using a fused-silica open tubular capillary column, 30 m x 0.25 mm I.D. coated with 5% phenylmethylsilicone and with a film thickness of 0.25 micron. Solvent extraction followed by saponification were sufficient to provide a purified extract which was directly analyzed for retinol by cGC in the solvent venting mode. However, in order to accurately determine alpha-tocopherol by cGC, further purification of the extract by solid-phase extraction was necessary. A silica SPE column was used to remove interfering cholesterol from the extract. alpha-Tocopherol was analyzed in its derivatized form. Absolute and relative recoveries for both vitamins from spiked samples were evaluated. Absolute and relative recoveries ranging from 80 to 95% were obtained for both compounds. 5 alpha-Cholestane and alpha-tocopheryl acetate were used as internal standards. Poultry muscle meat and liver tissue were analyzed for their retinol and alpha-tocopherol content and the peaks detected by cGC were confirmed by cGC-mass spectrometry.
A solid-phase extraction (SPE) method was developed using 8 M urea to desorb and extract organochlorine pesticides (OCs) and polychlorinated biphenyls (PCBs) from avian serum for analysis by capillary gas chromatography with electron capture detection (GC-ECD). The analytes were ...
NASA Astrophysics Data System (ADS)
Pepich, Barry V.; Callis, James B.; Danielson, J. D. Sheldon; Gouterman, Martin
1986-05-01
A method for detection of capillary gas chromatographic (C-GC) effluent using supersonic jet spectroscopy is described. A novel concept is introduced which overcomes four major obstacles: (i) high temperature of the GC; (ii) low GC flow rate; (iii) low dead volume requirement; and (iv) duty factor mismatch to a pulsed laser. The effluent from the C-GC flows into a low dead volume antechamber into which a pulsed valve, operating at 5 Hz, discharges high-pressure inert gas for 600 μs. The antechamber feeds through a small orifice into a high-vacuum chamber; here an isentropic expansion takes place which causes marked cooling of the GC effluent. The fluorescence of the effluent is then excited by a synchronously pulsed dye laser. With iodine vapor in helium (2 ml/min) modeling the GC effluent, the fluorescence of the cooled molecules is monitored with different delay times between opening of the pulsed valve and firing of the laser. With a glass wool plug inserted in the antechamber to promote mixing between the high-pressure pulse gas and the iodine, the observed pressure variation with time follows a simple gas-dynamic model. Operating in this pulsed mode it is found that the effluent concentration increases by a factor of 7 while the rotational temperature drops from 373 to 7 K. The overall fluorescence intensity actually increases nearly 30-fold because the temperature drop narrows the absorption bands. Tests on acenaphthene chromatographed on a 15-m capillary column show that the antechamber does not degrade resolution and that the high-pressure pulses act to reduce C-GC retention times, presumably through a Venturi effect. The antechamber can be operated with GC effluent temperatures above 200 °C without adversely affecting the pulsed valve.
Pico-CSIA: Picomolar Scale Compound-Specific Isotope Analyses
NASA Astrophysics Data System (ADS)
Baczynski, A. A.; Polissar, P. J.; Juchelka, D.; Schwieters, J. B.; Hilkert, A.; Freeman, K. H.
2016-12-01
The basic approach to analyzing molecular isotopes has remained largely unchanged since the late 1990s. Conventional compound-specific isotope analyses (CSIA) are conducted using capillary gas chromatography (GC), a combustion interface, and an isotope-ratio mass spectrometer (IRMS). Commercially available GC-IRMS systems are comprised of components with inner diameters ≥0.25 mm and employ helium flow rates of 1-4 mL/min. These flow rates are an order of magnitude larger than what the IRMS can accept. Consequently, ≥90% of the sample is lost through the open split, and 1-10s of nanomoles of carbon are required for analysis. These sample requirements are prohibitive for many biomarkers, which are often present in picomolar concentrations. We utilize the resolving power and low flows of narrow-bore capillary GC to improve the sensitivity of CSIA. Narrow bore capillary columns (<0.25 mm ID) allow low helium flow rates of ≤0.5mL/min for more efficient sample transfer to the ion source of the IRMS while maintaining the high linear flow rates necessary to preserve narrow peak widths ( 250 ms). The IRMS has been fitted with collector amplifiers configured to 25 ms response times for rapid data acquisition across narrow peaks. Previous authors (e.g., Sacks et al., 2007) successfully demonstrated improved sensitivity afforded by narrow-bore GC columns. They reported an accuracy and precision of 1.4‰ for peaks with an average width at half maximum of 720 ms for 100 picomoles of carbon on column. Our method builds on their advances and further reduces peak widths ( 600 ms) and the amount of sample lost prior to isotopic analysis. Preliminary experiments with 100 picomoles of carbon on column show an accuracy and standard deviation <1‰. With further improvement, we hope to demonstrate robust isotopic analysis of 10s of picomoles of carbon, more than 2 orders of magnitude lower than commercial systems. The pico-CSIA method affords high-precision isotopic analyses for picomoles of carbon in organic biomarkers, which significantly lowers sample size requirements and broadens analytical windows in paleoclimate, astrobiological, and biogeochemical research.
Separation of fatty acid methyl esters by GC-online hydrogenation × GC.
Delmonte, Pierluigi; Fardin-Kia, Ali Reza; Rader, Jeanne I
2013-02-05
The separation of fatty acid methyl esters (FAME) provided by a 200 m × 0.25 mm SLB-IL111 capillary column is enhanced by adding a second dimension of separation ((2)D) in a GC × GC design. Rather than employing two GC columns of different polarities or using different elution temperatures, the separation in the two-dimensional space is achieved by altering the chemical structure of selected analytes between the two dimensions of separation. A capillary tube coated with palladium is added between the first dimension of separation ((1)D) column and the cryogenic modulator, providing the reduction of unsaturated FAMEs to their fully saturated forms. The (2)D separation is achieved using a 2.5 m × 0.10 mm SLB-IL111 capillary column and separates FAMEs based solely on their carbon skeleton. The two-dimensional separation can be easily interpreted based on the principle that all the saturated FAMEs lie on a straight diagonal line bisecting the separation plane, while the FAMEs with the same carbon skeleton but differing in the number, geometric configuration or position of double bonds lie on lines parallel to the (1)D time axis. This technique allows the separation of trans fatty acids (FAs) and polyunsaturated FAs (PUFAs) in a single experiment and eliminates the overlap between PUFAs with different chain lengths. To our knowledge, this the first example of GC × GC in which a chemical change is instituted between the two dimensions to alter the relative retentions of components and identify unsaturated FAMEs.
NASA Astrophysics Data System (ADS)
Hardee, John R.; Long, John; Otts, Julie
2002-05-01
A senior-level undergraduate laboratory experiment that demonstrates the use of solid-phase microextraction (SPME) and capillary gas chromatography-mass spectrometry (GC-MS) was developed for the quantitative determination of bromoform in swimming pool water. Bromoform was extracted by SPME from the headspace of vials containing sodium chloride-saturated swimming pool water. Bromoform concentrations were determined from comparisons of peak areas on a student-generated calibration curve. Students compared results to OSHA water and air exposure limits for bromoform.
Tan, Hui Peng; Wan, Tow Shi; Min, Christina Liew Shu; Osborne, Murray; Ng, Khim Hui
2014-03-14
A selectable one-dimensional ((1)D) or two-dimensional ((2)D) gas chromatography-mass spectrometry (GC-MS) system coupled with flame ionization detector (FID) and olfactory detection port (ODP) was employed in this study to analyze perfume oil and fragrance in shower gel. A split/splitless (SSL) injector and a programmable temperature vaporization (PTV) injector are connected via a 2-way splitter of capillary flow technology (CFT) in this selectable (1)D/(2)D GC-MS/FID/ODP system to facilitate liquid sample injections and thermal desorption (TD) for stir bar sorptive extraction (SBSE) technique, respectively. The dual-linked injectors set-up enable the use of two different injector ports (one at a time) in single sequence run without having to relocate the (1)D capillary column from one inlet to another. Target analytes were separated in (1)D GC-MS/FID/ODP and followed by further separation of co-elution mixture from (1)D in (2)D GC-MS/FID/ODP in single injection without any instrumental reconfiguration. A (1)D/(2)D quantitative analysis method was developed and validated for its repeatability - tR; calculated linear retention indices (LRI); response ratio in both MS and FID signal, limit of detection (LOD), limit of quantitation (LOQ), as well as linearity over a concentration range. The method was successfully applied in quantitative analysis of perfume solution at different concentration level (RSD≤0.01%, n=5) and shower gel spiked with perfume at different dosages (RSD≤0.04%, n=5) with good recovery (96-103% for SSL injection; 94-107% for stir bar sorptive extraction-thermal desorption (SBSE-TD). Copyright © 2014 Elsevier B.V. All rights reserved.
CE is rarely used for routine environmental analysis of organic pollutants -- certainly not to the extent of gas chromatography or high pressure liquid chromatography. There are advantages to CE, however, that belie this lack of application. For example, CE is preferred over GC f...
Wong, Jon W; Webster, Michael G; Bezabeh, Dawit Z; Hengel, Mathew J; Ngim, Kenley K; Krynitsky, Alexander J; Ebeler, Susan E
2004-10-20
A method was developed to determine pesticides in malt beverages using solid phase extraction on a polymeric cartridge and sample cleanup with a MgSO4-topped aminopropyl cartridge, followed by capillary gas chromatography with electron impact mass spectrometry in the selected ion monitoring mode [GC-MS(SIM)]. Three GC injections were required to analyze and identify organophosphate, organohalogen, and organonitrogen pesticides. The pesticides were identified by the retention times of peaks of the target ion and qualifier-to-target ion ratios. GC detection limits for most of the pesticides were 5-10 ng/mL, and linearity was determined from 50 to 5000 ng/mL. Fortification studies were performed at 10 ng/mL for three malt beverages that differ in properties such as alcohol content, solids, and appearance. The recoveries from the three malt beverages were greater than 70% for 85 of the 142 pesticides (including isomers) studied. The data showed that the different malt beverage matrixes had no significant effect on the recoveries. This method was then applied to the screening and analysis of malt beverages for pesticides, resulting in the detection of the insectide carbaryl and the fungicide dimethomorph in real samples. The study indicates that pesticide levels in malt beverages are significantly lower than the tolerance levels set by the United States Environmental Protection Agency for malt beverage starting ingredients. The use of the extraction/cleanup procedure and analysis by GC-MS(SIM) proved effective in screening malt beverages for a wide variety of pesticides. Copyright 2004 American Chemical Society
Determination of residual solvents in pharmaceuticals by thermal desorption-GC/MS.
Hashimoto, K; Urakami, K; Fujiwara, Y; Terada, S; Watanabe, C
2001-05-01
A novel method for the determination of residual solvents in pharmaceuticals by thermal desorption (TD)-GC/MS has been established. A programmed temperature pyrolyzer (double shot pyrolyzer) is applied for the TD. This method does not require any sample pretreatment and allows very small amounts of the sample. Directly desorbed solvents from intact pharmaceuticals (ca. 1 mg) in the desorption cup (5 mm x 3.8 mm i.d.) were cryofocused at the head of a capillary column prior to a GC/MS analysis. The desorption temperature was set at a point about 20 degrees C higher than the melting point of each sample individually, and held for 3 min. The analytical results using 7 different pharmaceuticals were in agreement with those obtained by direct injection (DI) of the solution, followed by USP XXIII. This proposed TD-GC/MS method was demonstrated to be very useful for the identification and quantification of residual solvents. Furthermore, this method was simple, allowed rapid analysis and gave good repeatability.
Zeng, Annie Xu; Chin, Sung-Tong; Nolvachai, Yada; Kulsing, Chadin; Sidisky, Leonard M; Marriott, Philip J
2013-11-25
Due to their distinct chemical properties, the application of ionic liquid (IL) compounds as gas chromatography (GC) stationary phases offer unique GC separation especially in the analysis of geometric and positional fatty acid methyl ester (FAME) isomers. Elution behaviour of FAME on several commercialised IL capillary columns including phosphonium based SLB-IL59, SLB-IL60, SLB-IL61 and SLB-IL76 and imidazolium based SLB-IL82, SLB-IL100, and SLB-IL111 as well as a general purpose column SLB-5ms, were evaluated in gas chromatography-mass spectrometry (GC-MS) analysis. The phases were further characterised by using a linear solvation energy relationship (LSER) approach according to the equivalent chain length (ECL) index of FAME. Among all tested IL columns, elution temperatures of saturated FAME increased as their McReynolds' polarity value decreased, except for IL60. ECL values increased markedly as the stationary phase polarity increased, particularly for the polyunsaturated FAME. The LSER study indicated a lowest l/e value at 0.864 for IL111, displaying phase selectivity towards unsaturated FAME, with higher peak capacity within a carbon number isomer group. s and e descriptors calculated from LSER were validated by excellent correlation with dipole moments and lowest unoccupied molecular orbital (LUMO) energies, with R(2) values of 0.99 and 0.92 respectively, calculated using GAUSSIAN. Copyright © 2013 Elsevier B.V. All rights reserved.
Sambataro, Domenico; Sambataro, Gianluca; Zaccara, Eleonora; Maglione, Wanda; Polosa, Riccardo; Afeltra, Antonella M V; Vitali, Claudio; Del Papa, Nicoletta
2014-10-09
Nailfold videocapillaroscopy (NVC) in systemic sclerosis (SSc) is a procedure commonly used for patient classification and subsetting, but not to define disease activity (DA). This study aimed to evaluate whether the number of micro-haemorrhages (MHE), micro-thrombosis (MT), giant capillaries (GC), and normal/dilated capillaries (Cs) in NVC could predict DA in SSc. Eight-finger NVC was performed in 107 patients with SSc, and the total number of MHE/MT, GC, and the mean number of Cs were counted and defined as number of micro-haemorrhages (NEMO), GC and Cs scores, respectively. The European Scleroderma Study Group (ESSG) index constituted the gold standard for DA assessment, and scores ≥ 3.5 and = 3 were considered indicative of high and moderate activity, respectively. NEMO and GC scores were positively correlated with ESSG index (R = 0.65, P < 0.0001, and R = 0.47, P <0.0001, respectively), whilst Cs score showed a negative correlation with that DA index (R = -0.30, P <0.001). The area under the curve (AUC) of receiver operating characteristic plots, obtained by NEMO score sensitivity and specificity values in classifying patients with ESSG index ≥ 3.5, was significantly higher than the corresponding AUC derived from either GC or Cs scores (P <0.03 and P <0.0006, respectively). A modified score, defined by the presence of a given number of MHE/MT and GC, had a good performance in classifying active patients (ESSG index ≥ 3, sensitivity 95.1%, specificity 84.8%, accuracy 88.7%). MHE/MT and GC appear to be good indicators of DA in SSc, and enhances the role of NVC as an easy technique to identify active patients.
Aprea, C; Sciarra, G; Bozzi, N
1997-01-01
Two methods for the quantitative analysis of 2,4-dichlorophenoxyacetic acid (2,4-D) and 2-methyl-4-chlorophenoxyacetic acid (MCPA) in urine were compared. The first was an high-performance liquid chromatography method using a C8 column with ion suppression and diode array detection. The urine extracts were first purified by solid-phase extraction (SPE) on silica capillary columns. The detection limit of the method was 15 micrograms/L for both compounds. The percentage coefficient of variation of the whole analysis evaluated at a concentration of 125.0 micrograms/L was 6.2% for 2,4-D and 6.8% for MCPA. The mean recovery of analysis was 81% for 2,4-D and 85% for MCPA. The second was a gas chromatographic (GC) method in which the compounds were first derivatized with pentafluorobenzylbromide to pentafluorobenzyl esters, which were determined with a slightly polar capillary column and electron capture detection. Before GC analysis, the urine extracts were purified by SPE on silica capillary columns. This method had a detection limit of 1 microgram/L for both compounds and a percentage coefficient of variation of the whole analysis, evaluated at a concentration of 30.0 micrograms/L, of 8% for 2,4-D, and of 5.5% for MCPA. the mean recovery was 87% for 2,4-D and 94% for MCPA. The low detection limit made the second method suitable for assaying the two herbicides in the general population. Duplicate analysis of ten urine samples from occupationally exposed subjects by the two methods gave identical results for a wide range of concentrations.
Portable gas chromatograph-mass spectrometer
Andresen, Brian D.; Eckels, Joel D.; Kimmons, James F.; Myers, David W.
1996-01-01
A gas chromatograph-mass spectrometer (GC-MS) for use as a field portable organic chemical analysis instrument. The GC-MS is designed to be contained in a standard size suitcase, weighs less than 70 pounds, and requires less than 600 watts of electrical power at peak power (all systems on). The GC-MS includes: a conduction heated, forced air cooled small bore capillary gas chromatograph, a small injector assembly, a self-contained ion/sorption pump vacuum system, a hydrogen supply, a dual computer system used to control the hardware and acquire spectrum data, and operational software used to control the pumping system and the gas chromatograph. This instrument incorporates a modified commercial quadrupole mass spectrometer to achieve the instrument sensitivity and mass resolution characteristic of laboratory bench top units.
Manca, Alessandra; Alladio, Eugenio; Massarenti, Paola; Puccinelli, M Paola; De Francesco, Antonella; Del Grosso, Erika; Mengozzi, Giulio; Pazzi, Marco; Vincenti, Marco
2017-12-01
A simple "one-pot" derivatization and liquid-liquid extraction (LLE) procedure was developed for GC-MS analysis of reduced glutathione (GSH) analysis in erythrocytes. The metabolite was extracted by 5% (w/v) TCA, the supernatant treated with ECF and ethanol-pyridine media, the derivative separated and detected by gas chromatography-mass spectrometry using a short non-polar capillary GC column at a high column-head pressure. Total analysis time was 11min. The process was optimized by a Design of Experiment. The method was validated showing a good linearity over the 25.4-813.4μM concentration range, providing satisfactory results in terms of intra-day and inter-day precision as well as an optimal accuracy. The new method was evaluated in a pilot study involving patients with severe protein malnutrition. Comparison of this group with a group of healthy subjects revealed significantly lower GSH concentrations in erythrocytes in the former, thus proving that the described GC-MS method could be employed for fast and simple GSH analysis in clinical studies. Copyright © 2017 Elsevier B.V. All rights reserved.
Chen, Qinhua; Li, Peng; Zhang, Zhuo; Li, Kaijun; Liu, Jia; Li, Qiang
2008-07-01
In the present work, the qualitative and quantitative analysis of Pausinystalia yohimbe-type alkaloids in the barks of Rubiaceae species is presented using different analytical approaches. Extracts of P. yohimbe were first examined by GC-MS and the major alkaloids were identified. The quantitation of yohimbine was then accomplished by non-aqueous CE (NACE) with diode array detection. This approach was selected in order to use a running buffer fully compatible with samples in organic solvent. In particular, a mixture of methanol containing ammonium acetate (20 mM) and glacial acetic acid was used as a BGE. The same analytical sample was subjected to GC-MS and NACE analysis; the different selectivity displayed by these techniques allowed different separation profiles that can be useful in phytochemical characterization of the extracts. The linear calibration ranges were all 10-1000 microg/mL for yohimbine by GC-MS and NACE analysis. The recovery of yohimbine was 91.2-94.0% with RSD 1.4-4.3%. The LOD for yohimbine were 0.6 microg/mL by GC-MS and 1.0 microg/mL by NACE, respectively. The GC-MS and NACE methods were successfully validated and applied to the quantitation of yohimbine.
π-Extended triptycene-based material for capillary gas chromatographic separations.
Yang, Yinhui; Wang, Qinsi; Qi, Meiling; Huang, Xuebin
2017-10-02
Triptycene-based materials feature favorable physicochemical properties and unique molecular recognition ability that offer good potential as stationary phases for capillary gas chromatography (GC). Herein, we report the investigation of utilizing a π-extended triptycene material (denoted as TQPP) for GC separations. As a result, the TQPP capillary column exhibited high column efficiency of 4030 plates m -1 and high-resolution performance for a wide range of analytes, especially structural and positional isomers. Interestingly, the TQPP stationary phase showed unique shape selectivity for alkanes isomers and preferential retention for analytes with halogen atoms and H-bonding nature mainly through their halogen-bonding and H-bonding interactions. In addition, the TQPP column had good repeatability and reproducibility with the RSD values of 0.02-0.34% for run-to-run, 0.09-0.80% for day-to-day and 1.4-5.2% for column-to-column, respectively, and favorable thermal stability up to 280 °C. This work demonstrates the promising future of triptycene-based materials as a new class of stationary phases for GC separations. Copyright © 2017 Elsevier B.V. All rights reserved.
USDA-ARS?s Scientific Manuscript database
(DF), D. moldavica L. (DM), D. fruticulosum Steph. ex Willd. (DFr) and D. peregrinum L. (DP) were evaluated. Simultaneous GC-FID and GC-MS analyses revealed in the EOs of DR, DF and DM an unidentified compound (1) ([M+122], 5.4%, 57.9% and 74.0%, respectively). Therefore, we aimed to isolate compoun...
Darko, Ernest; Thurbide, Kevin B
2016-09-23
The use of a pH-adjusted water stationary phase for analyzing organic bases in capillary gas chromatography (GC) is demonstrated. Through modifying the phase to typical values near pH 11.5, it is found that various organic bases are readily eluted and separated. Conversely, at the normal pH 7 operating level, they are not. Sodium hydroxide is found to be a much more stable base than ammonium hydroxide for altering the pH due to the higher volatility and evaporation of the latter. In the basic condition, such analytes are not ionized and are observed to produce good peak shapes even for injected masses down to about 20ng. By comparison, analyses on a conventional non-polar capillary GC column yield more peak tailing and only analyte masses of 1μg or higher are normally observed. Through carefully altering the pH, it is also found that the selectivity between analytes can be potentially further enhanced if their respective pKa values differ sufficiently. The analysis of different pharmaceutical and petroleum samples containing organic bases is demonstrated. Results indicate that this approach can potentially offer unique and beneficial selectivity in such analyses. Copyright © 2016 Elsevier B.V. All rights reserved.
Portable gas chromatograph-mass spectrometer
Andresen, B.D.; Eckels, J.D.; Kimmons, J.F.; Myers, D.W.
1996-06-11
A gas chromatograph-mass spectrometer (GC-MS) is described for use as a field portable organic chemical analysis instrument. The GC-MS is designed to be contained in a standard size suitcase, weighs less than 70 pounds, and requires less than 600 watts of electrical power at peak power (all systems on). The GC-MS includes: a conduction heated, forced air cooled small bore capillary gas chromatograph, a small injector assembly, a self-contained ion/sorption pump vacuum system, a hydrogen supply, a dual computer system used to control the hardware and acquire spectrum data, and operational software used to control the pumping system and the gas chromatograph. This instrument incorporates a modified commercial quadrupole mass spectrometer to achieve the instrument sensitivity and mass resolution characteristic of laboratory bench top units. 4 figs.
Rambla-Alegre, Maria; Tienpont, Bart; Mitsui, Kazuhisa; Masugi, Eri; Yoshimura, Yuta; Nagata, Hisanori; David, Frank; Sandra, Pat
2014-10-24
Aroma characterization of whole cigarette smoke samples using sensory panels or electronic nose (E-nose) devices is difficult due to the masking effect of major constituents and solvent used for the extraction step. On the other hand, GC in combination with olfactometry detection does not allow to study the delicate balance and synergetic effect of aroma solutes. To overcome these limitations a new instrumental set-up consisting of heart-cutting gas chromatography using a capillary flow technology based Deans switch and low thermal mass GC in combination with an electronic nose device is presented as an alternative to GC-olfactometry. This new hyphenated GC-E-nose configuration is used for the characterization of cigarette smoke aroma. The system allows the transfer, combination or omission of selected GC fractions before injection in the E-nose. Principal component analysis (PCA) and discriminant factor analysis (DFA) allowed clear visualizing of the differences among cigarette brands and classifying them independently of their nicotine content. Omission and perceptual interaction tests could also be carried out using this configuration. The results are promising and suggest that the GC-E-nose hyphenation is a good approach to measure the contribution level of individual compounds to the whole cigarette smoke. Copyright © 2014 Elsevier B.V. All rights reserved.
A capillary gas chromatography-atomic emission detection (GC-AED) method was developed for the U. S. Environmental Protection Agency's Environmental Monitoring Systems Laboratory in Las Vegas, NV, for determination of selected organotin compounds. Here we report on an interlabora...
A method for the determination of low molecular weight aldehydes in water using aqueous-phase derivatization with O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine hydrochloride has been improved by the use of high-resolution capillary GC. Detection limits with GC/ECD and GC/MS with ...
Zhang, Zhengxiang; Yan, Bo; Liu, Kelin; Liao, Yiping; Liu, Huwei
2009-01-01
The first application of charged polymer-protected gold nanoparticles (Au NPs) as semi-permanent capillary coating in CE-MS was presented. Poly(diallyldimethylammonium chloride) (PDDA) was the only reducing and stabilizing agent for Au NPs preparation. Stable and repeatable coating with good tolerance to 0.1 M HCl, methanol, and ACN was obtained via a simple rinsing procedure. Au NPs enhanced the coating stability toward flushing by methanol, improved the run-to-run and capillary-to-capillary repeatabilities, and improved the separation efficiency of heroin and its basic impurities for tracing geographical origins of illicit samples. Baseline resolution of eight heroin-related alkaloids was achieved on the PDDA-protected Au NPs-coated capillary under the optimum conditions: 120 mM ammonium acetate (pH 5.2) with addition of 13% methanol, separation temperature 20 degrees C, applied voltage -20 kV, and capillary effective length 60.0 cm. CE-MS analysis with run-to-run RSDs (n=5) of migration time in the range of 0.43-0.62% and RSDs (n=5) of peak area in the range of 1.49-4.68% was obtained. The established CE-MS method would offer sensitive detection and confident identification of heroin and related compounds and provide an alternative to LC-MS and GC-MS for illicit drug control.
Banerjee, Kaushik; Patil, Sangram H; Dasgupta, Soma; Oulkar, Dasharath P; Patil, Shubhangi B; Savant, Rahul; Adsule, Pandurang G
2008-05-09
A comprehensive GCxGC-TOFMS method was optimized for multiresidue analysis of pesticides using a combination of a non-polar (RTX-5MS, 10 m x 0.18 mm x 0.2 microm) and a polar capillary column (TR-50MS, 1 m x 0.1 mm x 0.1 microm), connected in series through a dual stage thermal modulator. The method resolved the co-elution problems as observed in full scan one-dimensional GC-MS analysis and allowed chromatographic separation of 51 pesticides within 24 min run time with library-searchable mass spectrometric confirmation. Four pesticides, viz. chlorpyrifos-methyl, vinclozoline, parathion-methyl and heptachlor could be baseline separated on GCxGC, which were otherwise closely eluting and interfering each other's detection in 1D GC-MS run. Similarly, it could be possible to separate myclobutanil, buprofezin, flusilazole and oxyfluorfen on GCxGC. Although in 1D GC-MS, these closely eluting compounds could be identified through deconvolution algorithm and 'peak-find' option of the Chromatof software but the spectral purity significantly improved on GCxGC analysis. Thorough optimization was accomplished for the oven temperature programming, ion source temperature and GCxGC parameters like modulation period, duration of hot pulses, modulation-offset temperature, acquisition rate, etc. to achieve best possible separation of the test compounds. The limit of detection significantly improved by 2-12 times on GCxGC-TOFMS against GC-TOFMS because of sharper and narrower peak shapes. The method was tested for grape matrix after preparing the samples using previously described method and recoveries of the entire test pesticides were within 70-110% at 10 ng/g level of fortification. GCxGC-TOFMS was found to be an excellent technique for library-based screening of pesticides with high accuracy and sensitivity.
As part of a continuing evaluation of new analytical and sample preparation techniques conducted by the US Environmental Protection Agency (EPA), the use of capillary gas chromatography with atomic emission detection (GC-AED) for the simultaneous determination of organotin, organ...
40 CFR 141.40 - Monitoring requirements for unregulated contaminants.
Code of Federal Regulations, 2011 CFR
2011-07-01
... monitoring to be completed Reserved i Reserved i Reserved i Reserved i Reserved i Reserved i Column headings... Pesticides and Flame Retardants in Drinking Water by Solid Phase Extraction and Capillary Column Gas... Water by Solid Phase Extraction and Capillary Column Gas Chromatography/Mass Spectrometry (GC/MS...
Krupčík, Ján; Májek, Pavel; Gorovenko, Roman; Blaško, Jaroslav; Kubinec, Robert; Sandra, Pat
2015-05-29
Methods based on the blank signal as proposed by IUPAC procedure and on the signal to noise ratio (S/N) as listed in the ISO-11843-1 norm for determination of the limit of detection (LOD) and quantitation (LOQ) in one-dimensional capillary gas chromatography (1D-GC) and comprehensive two-dimensional capillary gas chromatography (CG×GC) are described in detail and compared for both techniques. Flame ionization detection was applied and variables were the data acquisition frequency and, for CG×GC, also the modulation time. It has been stated that LOD and LOQ estimated according to IUPAC might be successfully used for 1D-GC-FID method. Moreover, LOD and LOQ decrease with decrease of data acquisition frequency (DAF). For GC×GC-FID, estimation of LOD by IUPAC gave poor reproducibility of results while for LOQ reproducibility was acceptable (within ±10% rel.). The LOD and LOQ determined by the S/N concept both for 1D-GC-FID and GC×GC-FID methods are ca. three times higher than those values estimated by the standard deviation of the blank. Since the distribution pattern of modulated peaks for any analyte separated by GC×GC is random and cannot be predicted, LOQ and LOD may vary within 30% for 3s modulation time. Concerning sensitivity, 1D-GC-FID at 2Hz and of GC×GC-FID at 50Hz shows a ca. 5 times enhancement of sensitivity in the modulated signal output. Copyright © 2015 Elsevier B.V. All rights reserved.
Fatty acid amides from freshwater green alga Rhizoclonium hieroglyphicum.
Dembitsky, V M; Shkrob, I; Rozentsvet, O A
2000-08-01
Freshwater green algae Rhizoclonium hieroglyphicum growing in the Ural Mountains were examined for their fatty acid amides using capillary gas chromatography-mass spectrometry (GC-MS). Eight fatty acid amides were identified by GC-MS. (Z)-9-octadecenamide was found to be the major component (2.26%).
Roberts, Mark T; Dufour, Jean-Pierre; Lewis, Alastair C
2004-04-01
The selection and quality of hops is a major determinant in beer flavour. Brewers acknowledge that distinctive characteristics of different hop varieties can be traced to the composition of their essential oils. The difficulty in characterising complex mixtures such as hop oil using 1-D chromatography is that many compounds co-elute. With the introduction of comprehensive multidimensional capillary gas chromatography (GC x GC), there is a tremendous improvement in the separation power or peak capacity. Recent work using GC x GC with flame ionisation detection has suggested that there may be over 1,000 compounds in hop oil. This work describes the use of GC x GC combined with TOFMS detection (Leco Pegasus 4D instrument) to analyse Target hop oil. The TOFMS spectral acquisition rate of 60 Hz provided sufficient spectra per peak (2-D peak base width of 0.1-0.2 s) for identification (119 components were identified with 45 previously unreported compounds). When analysing results, an advantage of GC x GC coupled to TOFMS is that 2-D chromatograms can be viewed for individual masses that are characteristic of particular functional groups. This allows the analyst to view the various homologous series of compounds although in certain cases coelution may still be present as shown by the esters with mass 75.
Surface Chemistry and Structural Effects in the Stress Corrosion of Glass and Ceramic Materials.
1986-03-31
capillary can be improved for (GC)2 by passing S sulfur dioxide or difluoroethane through the preform and capillary during the fabrication 27 . The...hydration resistance of the glass surface. In fact, it was recently shown that the combined use of sulfur dioxide and * difluoroethane could further
Determination of nandrolone and metabolites in urine samples from sedentary persons and sportsmen.
Galán Martín, A M; Mariño, J I; García de Tiedra, M P; Marabé, J J; Caballero Loscos, M J; Mariño, M M
2001-09-25
Metabolites of nandrolone were determined in the urine of several sportsmen, sedentary and post-menopausal women by capillary gas chromatography-mass spectrometry quadrupole (GC-MS) and capillary gas chromatography mass-mass spectrometry ion trap (GC-MS-MS) methods. The method employed was GC-EI-MS with 17alpha-methyltestosterone as internal standard with ethyl ether extraction prior to selected ion monitoring of the bis(trimethylsilyl) ethers at ion masses m/z 405 and 420 for the nandrolone metabolites, and 418 and 403 for nandrolone derivative. Recovery for nandrolone, 19-norandrosterone (19-NA) and 19-noretiocholanolone (19-NE) was 97.20, 94.17 and 95.54%, respectively. Detection limits for nandrolone, 19-NA and 19-NE were 0.03, 0.01 and 0.06 ng/ml. Metabolites of nandrolone (19-NA and 19-NE) were found in 12.5% (n = 40) of sportsmen and 40% (n = 10) of post-menopausal women.
1992-09-01
chromatography. * DI EXPLOSIVE ANALYSIS USING CAPILLARY ELECTROPHORESIS Bruce R . McCord., Forensic Science Research Unit, FBI Academy, Quantico, VA...gel and emulsion explosives E. Bender, R . Strobel, and C.R. Midkiff. Ir, Bureau of ATF, Rockville, MD, USA 11.05 D3 The analysis of the explosives of...organic substrates . . - r __ A.D. Wright, K.R. Jennings and R . Peters, University of Warwick, Coventry, U.K. 16:40 F2 GC/MS analysis of PETN and NG
Cajka, Tomás; Hajslová, Jana; Cochran, Jack; Holadová, Katerina; Klimánková, Eva
2007-03-01
Head-space solid phase microextration (SPME), followed by comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry (GCxGC-TOFMS), has been implemented for the analysis of honey volatiles, with emphasis on the optimal selection of SPME fibre and the first- and second-dimension GC capillaries. From seven SPME fibres investigated, a divinylbenzene/Carboxen/polydimethylsiloxane (DVB/CAR/PDMS) 50/30 microm fibre provided the best sorption capacity and the broadest range of volatiles extracted from the headspace of a mixed honey sample. A combination of DB-5ms x SUPELCOWAX 10 columns enabled the best resolution of sample components compared to the other two tested column configurations. Employing this powerful analytical strategy led to the identification of 164 volatile compounds present in a honey mixture during a 19-min GC run. Combination of this simple and inexpensive SPME-based sampling/concentration technique with the advanced separation/identification approach represented by GCxGC-TOFMS allows a rapid and comprehensive examination of the honey volatiles profile. In this way, the laboratory sample throughput can be increased significantly and, at the same time, the risk of erroneous identification, which cannot be avoided in one-dimensional GC separation, is minimised.
Method 525.3 is an analytical method that uses solid phase extraction (SPE) and gas chromatography/mass spectrometry (GC/MS) for the identification and quantitation of 125 selected semi-volatile organic chemicals in drinking water.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Woolley, C.L.; Mani, V.; Shirey, R.E.
1995-12-31
The persistence and widespread environmental occurrence of polychlorinated biphenyls (PCBs) in the air, waterways and industrial facilities has created a need for quantitative and qualitative analysis of Aroclor-like mixtures. Although there are 209 possible PCB concerns, only a limited number have shown toxic activity similar to 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD). The World Health Organization recently released a list of the 13 most toxic PCB congeners. Each was rated by its Toxic Equivalency Factor relative to TCDD. These 13 PCB congeners belong to the class of toxic coplanar compounds. These congeners commonly contain chlorosubstitutions in the 3,3{prime},4,4{prime} or 3,4,4{prime} or 3{prime},4,4{prime} positions andmore » either 0, 1, or 2 chloro-substituents in the ortho positions. A new capillary column containing a bonded octylmethyl polysiloxane stationary phase (SPB-Octyl) was evaluated for its propensity to separate coplanar PCB congeners. Solid phase microextraction (SPME), a solvent-free method for extracting volatiles and semi-volatiles from drinking water, waste water, soil and sludge was used to extract PCBs from soil. GC-ECD and GC-MS separations of PCB ladened soils were examined via SPME on the SPB-Octyl column. An approach for selective extraction of coplanar PCB congeners by SPME will be described.« less
Dumont, Emmie; Tienpont, Bart; Higashi, Nobukazu; Mitsui, Kazuhisa; Ochiai, Nobuo; Kanda, Hirooki; David, Frank; Sandra, Pat
2013-11-22
Gas chromatography coupled to isotope ratio mass spectrometry after on-line combustion (GC-C-IRMS) and high temperature conversion (GC-HTC-IRMS) is used for compound specific isotope ratio determination. This determination can only be performed successfully if the target solutes are fully resolved from other compounds. A new instrumental set-up consisting of heart-cutting two-dimensional GC based on capillary flow technology and a low thermal mass GC oven in combination with an isotope ratio mass spectrometer is presented. Capillary flow technology was also used in all column and interface connections for robust and leak-free operation. The new configuration was applied to the characterization of wax compounds in tobacco leaf and corresponding smoke samples. It is demonstrated that high accuracy is obtained, both in the determination of δ(13)C and δ(2)H values, allowing the study of biosynthesis and delivery mechanisms of naturally occurring compounds in tobacco. Copyright © 2013 Elsevier B.V. All rights reserved.
Prototype of an Interface for Hyphenating Distillation with Gas Chromatography and Mass Spectrometry
Tang, Ya-Ru; Yang, Hui-Hsien; Urban, Pawel L.
2017-01-01
Chemical analysis of complex matrices—containing hundreds of compounds—is challenging. Two-dimensional separation techniques provide an efficient way to reduce complexity of mixtures analyzed by mass spectrometry (MS). For example, gasoline is a mixture of numerous compounds, which can be fractionated by distillation techniques. However, coupling conventional distillation with other separations as well as MS is not straightforward. We have established an automatic system for online coupling of simple microscale distillation with gas chromatography (GC) and electron ionization MS. The developed system incorporates an interface between the distillation condenser and the injector of a fused silica capillary GC column. Development of this multidimensional separation (distillation-GC-MS) was preceded by a series of preliminary off-line experiments. In the developed technique, the components with different boiling points are fractionated and instantly analyzed by GC-MS. The obtained data sets illustrate dynamics of the distillation process. An important advantage of the distillation-GC-MS technique is that raw samples can directly be analyzed without removal of the non-volatile matrix residues that could contaminate the GC injection port and the column. Distilling the samples immediately before the injection to the GC column may reduce possible matrix effects—especially in the early phase of separation, when molecules with different volatilities co-migrate. It can also reduce losses of highly volatile components (during fraction collection and transfer). The two separation steps are partly orthogonal, what can slightly increase selectivity of the entire analysis. PMID:28337400
Zhang, Xinyu; Zhao, Liang; Wang, Yexin; Xu, Yunping; Zhou, Liping
2013-07-01
Preparative capillary GC (PCGC) is a powerful tool for the separation and purification of compounds from any complex matrix, which can be used for compound-specific radiocarbon analysis. However, the effect of PCGC parameters on the trapping efficiency is not well understood. Here, we present a comprehensive study on the optimization of parameters based on 11 reference compounds with different physicochemical properties. Under the optimum conditions, the trapping efficiencies of these 11 compounds (including high-boiling-point n-hentriacontane and methyl lignocerate) are about 80% (60-89%). The isolation of target compounds from standard solutions, plant and soil samples demonstrates that our optimized method is applicable for different classes of compounds including n-alkanes, fatty acid esters, long-chain fatty alcohol esters, polycyclic aromatic hydrocarbons (PAHs) and steranes. By injecting 25 μL in large volume injection mode, over 100 μg, high purity (>90%) target compounds are harvested within 24 h. The recovery ranges of two real samples are about 70% (59.9-83.8%) and about 83% (77.2-88.5%), respectively. Compared to previous studies, our study makes significant improvement in the recovery of PCGC, which is important for its wide application in biogeochemistry, environmental sciences, and archaeology. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Capillary electrophoresis in two-dimensional separation systems: Techniques and applications.
Kohl, Felix J; Sánchez-Hernández, Laura; Neusüß, Christian
2015-01-01
The analysis of complex samples requires powerful separation techniques. Here, 2D chromatographic separation techniques (e.g. LC-LC, GC-GC) are increasingly applied in many fields. Electrophoretic separation techniques show a different selectivity in comparison to LC and GC and very high separation efficiency. Thus, 2D separation systems containing at least one CE-based separation technique are an interesting alternative featuring potentially a high degree of orthogonality. However, the generally small volumes and strong electrical fields in CE require special coupling techniques. These technical developments are reviewed in this work, discussing benefits and drawbacks of offline and online systems. Emphasis is placed on the design of the systems, their coupling, and the detector used. Moreover, the employment of strategies to improve peak capacity, resolution, or sensitivity is highlighted. Various applications of 2D separations with CE are summarized. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
MacLennan, Matthew S; Peru, Kerry M; Swyngedouw, Chris; Fleming, Ian; Chen, David D Y; Headley, John V
2018-05-15
Oil sands mining in Alberta, Canada, requires removal and stockpiling of considerable volumes of near-surface overburden material. This overburden includes lean oil sands (LOS) which cannot be processed economically but contain sparingly soluble petroleum hydrocarbons and naphthenic acids, which can leach into environmental waters. In order to measure and track the leaching of dissolved constituents and distinguish industrially derived organics from naturally occurring organics in local waters, practical methods were developed for characterizing multiple sources of contaminated water leakage. Capillary electrophoresis/positive-ion electrospray ionization low-resolution time-of-flight mass spectrometry (CE/LRMS), high-resolution negative-ion electrospray ionization Orbitrap mass spectrometry (HRMS) and conventional gas chromatography/flame ionization detection (GC/FID) were used to characterize porewater samples collected from within Athabasca LOS and mixed surficial materials. GC/FID was used to measure total petroleum hydrocarbon and HRMS was used to measure total naphthenic acid fraction components (NAFCs). HRMS and CE/LRMS were used to characterize samples according to source. The amounts of total petroleum hydrocarbon in each sample as measured by GC/FID ranged from 0.1 to 15.1 mg/L while the amounts of NAFCs as measured by HRMS ranged from 5.3 to 82.3 mg/L. Factors analysis (FA) on HRMS data visually demonstrated clustering according to sample source and was correlated to molecular formula. LRMS coupled to capillary electrophoresis separation (CE/LRMS) provides important information on NAFC isomers by adding analyte migration time data to m/z and peak intensity. Differences in measured amounts of total petroleum hydrocarbons by GC/FID and NAFCs by HRMS indicate that the two methods provide complementary information about the nature of dissolved organic species in a soil or water leachate samples. NAFC molecule class O x S y is a possible tracer for LOS seepage. CE/LRMS provides complementary information and is a feasible and practical option for source evaluation of NAFCs in water. Copyright © 2018 John Wiley & Sons, Ltd.
Chen, Fong-Yi; Chang, Wei-Cheng; Jian, Rih-Sheng; Lu, Chia-Jung
2014-06-03
This paper presents the design, assembly, and evaluation of a novel gas chromatographic detector intended to measure the absorbance of the localized surface plasmon resonance (LSPR) of a gold nanoparticle monolayer in response to eluted samples from a capillary column. Gold nanoparticles were chemically immobilized on the inner wall of a glass capillary (i.d. 0.8 mm, length = 5-15 cm). The eluted samples flowed through the glass capillary and were adsorbed onto a gold nanoparticle surface, which resulted in changes in the LSPR absorbance. The LSPR probing light source used a green light-emitting diode (LED; λ(center) = 520 nm), and the light traveled through the glass wall of the capillary with multiple total reflections. The changes in the light intensity were measured by a photodiode at the rear of the glass capillary. The sensitivity of this detector can be improved by using a longer spiral glass capillary. The detector is more sensitive when operated at a lower temperature and at a slower carrier velocity. The calibration lines of 8 preliminary test compounds were all linear (R(2) > 0.99). The detection limits (3σ) ranged from 22 ng (n-butanol) to 174 ng (2-pentanone) depending on the volatility of the chemicals and the affinity to the citrate lignads attached to the gold nanoparticle surface. This detector consumed a very low amount of energy and could be operated with an air carrier gas, which makes this detector a promising option for portable GC or μGC.
Khalil, M W; Lawson, V
1983-04-01
Steroids in porcine follicular fluid have been concentrated by reverse phase chromatography in SEP-PAK C18 and purified further on the cation exchanger SP-Sephadex C-25. Fractionation into unconjugated neutral and phenolic steroids, glucuronides and sulfates was carried out on triethylaminohydroxypropyl Sephadex LH-20 (TEAP-LH-20). The unconjugated neutral fraction was analysed by high pressure liquid chromatography (HPLC) on a C18 radial cartridge 5 mm I.D.; 10 mu, or on a C18 5 mu RESOLVE column, and by capillary gas chromatography (GC) on a 12 M OV-1 cross linked fused silica column. Testosterone, progesterone and androstenedione were the major steroids detected by HPLC monitored at 254 nm, although 17- hydroxy-, 20 alpha-dihydro- and 20 beta-dihydroprogesterone were also present. Pregnenolone, pregnanediol, dehydroepiandrosterone, 17-hydroxypregnenolone and androsterone were detected by capillary CG as their 0-methyloxime trimethylsilyether derivatives. Further confirmation of structure was provided by complete mass spectral data or by selective ion monitoring (SIM).
Kulkarni, Sameer; Shearrow, Anne M; Malik, Abdul
2007-12-07
Sol-gel coating with covalently bonded low-molecular-weight (MW<300 Da) poly(ethylene glycol) (PEG) chains was developed for capillary microextraction (CME). The sol-gel chemistry proved effective in the immobilization of low-molecular-weight PEGs thanks to the formation of chemical bonds between the organic-inorganic hybrid sol-gel PEG coating and the fused silica capillary inner surface. This chemical anchorage provided excellent thermal and solvent stability to the created sol-gel PEG coating as is evidenced by its high upper limit of allowable conditioning temperature (340 degrees C) and its practically identical performance before and after rinsing with various solvents. The prepared sol-gel PEG coating provided simultaneous extraction of moderately polar and highly polar analytes from aqueous samples without requiring derivatization, pH adjustment or salting-out procedures. Detection limits on the order of nanogram per liter (ng/L) were achieved in CME-GC-flame ionization detection experiments designed for the preconcentration and trace analysis of both highly polar and moderately polar compounds extracted directly from aqueous media using sol-gel short-chain PEG coated microextraction capillaries.
Nakamura, S; Takino, M; Daishima, S
2001-04-06
Gas chromatography-mass spectrometry (GC-MS) with a temperature-programmable pyrolyzer was used for the analysis of waterborne paints. Evolved gas analysis (EGA) profiles of the waterborne paints were obtained by this temperature-programmed pyrolysis directly coupled with MS via a deactivated metal capillary tube. The EGA profile suggested the optimal thermal desorption conditions for solvents and additives and the subsequent optimal pyrolysis temperature for the remaining polymeric material. Polymers were identified from pyrograms with the assistance of a new polymer library. The solvents were identified from the electron ionization mass spectra with the corresponding chemical ionization mass spectra. The additive was identified as zinc pyrithione by comparison with authentic standard. Zinc pyrithione cannot be analyzed by GC-MS as it is. However, the thermal decomposition products of zinc pyrithione could be detected. The information on the decomposition temperature and products was useful for the identification of the original compound.
USDA-ARS?s Scientific Manuscript database
In the present work multiple component isolation from the oil of Crinitaria tatarica (Less.) Sojak. by Preparative Capillary Gas Chromatography (PCGC) with characterization by mass spectrometry (MS) and nuclear magnetic resonance (NMR) spectroscopy have been carried out. Gas chromatography (GC-FID) ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holland, M.L.; Uetz, J.A.; Ng, K.T.
1986-03-01
McN-5707 x HBr (trans-6-(2-chlorophenyl)-1,2,3,5,6,10b-hexa-hydropyrrolo(2,1-a)isoquinoline hydrobromide (1:1)) is a novel, potential antidepressant which is currently under pre-clinical evaluation. The present study reports the development of a sensitive and reproducible capillary gas chromatographic (GC) assay with nitrogen-phosphorus ionization detection (NPD) for McN-5707 in plasma. The assay includes a three step extraction as follows: McN-5707 and the internal standard (IS) are extracted from alkalinized plasma (1 mL) into hexane and back-extracted into 0.1 N HCl. Following alkalinization of the aqueous layer, McN-5707 and IS are re-extracted into hexane. The solvent is evaporated and the residue is reconstituted with 50 ..mu..L of a solutionmore » of 10% methanol in toluene. A 2.5 ..mu..L aliquot is injected into an HP 5880A capillary GC using the HP 7672A auto-sampler. Separation is accomplished using a 15 m x 0.32 mm i.d. DB-5 fused silica capillary column and temperature programming from 160 to 200/sup 0/C at 10/sup 0//min. Calibration curves are linear from 1 to 100 ng/mL. Accuracy and precision, expressed as relative deviation from the true value and coefficient of variation are < 10% at all concentrations in the linear range. The assay has been successfully used for pharmacokinetic studies in rats and dogs and has been cross-validated with a /sup 3/H-norepinephrine uptake inhibition assay.« less
Development of an SPE/CE method for analyzing HAAs
Zhang, L.; Capel, P.D.; Hozalski, R.M.
2007-01-01
The haloacetic acid (HAA) analysis methods approved by the US Environmental Protection Agency involve extraction and derivatization of HAAs (typically to their methyl ester form) and analysis by gas chromatography (GC) with electron capture detection (ECD). Concerns associated with these methods include the time and effort of the derivatization process, use of potentially hazardous chemicals or conditions during methylation, poor recoveries because of low extraction efficiencies for some HAAs or matrix effects from sulfate, and loss of tribromoacetic acid because of decarboxylation. The HAA analysis method introduced here uses solid-phase extraction (SPE) followed by capillary electrophoresis (CE) analysis. The method is accurate, reproducible, sensitive, relatively safe, and easy to perform, and avoids the use of large amounts of solvent for liquid-liquid extraction and the potential hazards and hassles of derivatization. The cost of analyzing HAAs using this method should be lower than the currently approved methods, and utilities with a GC/ECD can perform the analysis in-house.
Ghiasvand, Ali Reza; Yazdankhah, Fatemeh
2017-03-03
A polyaniline/multi-wall carbon nanotubes (PANI/MWCNT) composite was electrodeposited on the interior surface of a platinized stainless steel capillary needle and used to prepare an inside needle capillary adsorption trap (INCAT) device. The platinization expanded the interior adsorbing surface of the needle and made it more porous and cohesive for nanocomposite film. The nanocomposite was characterized using scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FT-IR). The fabricated INCAT was fixed into a cooling capsule to fabricate a cooling-assisted INCAT (CA-INCAT) system. The CA-INCAT device was used to extract polycyclic aromatic hydrocarbons (PAHs) from solid samples followed by gas chromatography-flame ionization detection (GC-FID) determination. To obtain the best extraction efficiency, the important experimental variables were studied and optimized. Under the optimal conditions, the limits of detection (LODs) for the studied PAHs were in the range of 0.002-0.02ngg -1 . Linear dynamic ranges (LDRs) for the calibration curves were found to be 0.1-30,000ngg -1 . Relative standard deviations (RSDs%) for six replicated analysis of 1ngg -1 PAHs were obtained 7.7-11%. The CA-INCAT-GC-FID method was successfully applied for the extraction and determination of PAHs in contaminated soil samples. The results were in agreement with those obtained by a validated ultrasound-assisted solvent extraction (UA-SE) method. Copyright © 2017 Elsevier B.V. All rights reserved.
[Analysis of terpineol and improvement of technology process in terpineol production].
Liang, Ming; Chen, Min; Cai, Chun-ping; Weng, Ruo-rong
2002-11-01
A method for the separation and determination of terpineol oil by temperature programming capillary gas chromatography has been established. An OV-1 fused silica capillary column (30 m x 0.32 mm i.d. x 0.25 microns) was used with a temperature increase rates of 1.5 degrees C/min from 70 degrees C to 100 degrees C, 5 degrees C/min from 100 degrees C to 160 degrees C, 10 degrees C/min from 160 degrees C to 220 degrees C and then hold for 2 min. The main chemical components and their relative contents of the terpineol oil, terpinene oil, red and yellow oils of middle oils in the terpineol production and natural terpineol were analyzed by capillary gas chromatography-Fourier transform infrared spectrometry (GC-FTIR) and gas chromatography-mass spectrometry (GC-MS). The typical chromatograms of these oils are given. It has offered the information of the boiling points of the chemical compounds, and it is helpful to reutilize them after their separation by rectification. The results showed that the main compounds of the heavy cut of terpineol were longifolene and beta-caryophyllene. They are from the raw material, terpinene oil. The main compounds in the natural terpineol oil were eucalyptol, trans-4-thujanol, p-isopropenyl toluene, cis-4-thujanol, linalool, camphor, borneol, 4-terpineol, alpha-terpineol and safrole. The contents of beta-terpineol and gamma-terpineol were not so high as in synthetic terpineol.
Sterol Profile for Natural Juices Authentification by GC-MS
NASA Astrophysics Data System (ADS)
Culea, M.
2007-04-01
A GC-MS analytical method is described for some natural juices analysis. The fingerprint of sterols was used to characterize the natural juice. A rapid liquid-liquid extraction method was used. The sterols were separated on a Rtx-5MS capillary column, 15m×0.25mm, 0.25μm film thickness, in a temperature program from 50°C for 1 min, then ramped at 15°C/min to 300°C and held for 15 min. Identification of sterols and their patterns were used for juice characterization. The sterol profile is a useful approach for confirming the presence of juices of orange, grapefruit, pineapple and passion fruit in compounded beverages and for detecting of adulteration of fruit juices.
Improved Flow Modulator Construction for GC × GC with Quadrupole Mass Spectrometry.
Ston, Martin; Cabala, Radomir; Bierhanzl, Vaclav Matej; Krajicek, Jan; Bosakova, Zuzana
2016-08-18
Improvement and testing of a flow modulator for the application in comprehensive two-dimensional gas chromatography separations is the subject of the presented paper. This improved setup constructed from two independent capillary branches each consisting of a pressure regulator, a pressure sensor, a two-way solenoid valve and a microfluidic T-connector, allows an independent and easy settings of the pressures and flow velocities in the modulator and provides system flexibility in an operation without need of any component exchange. The estimated flow rates were 0.4 mL/min in the first column and 3.2 mL/min in the second column. This setup was compared with the commercial Zoex cryogenic modulator for the separation of 17 selected solvents at isothermal conditions. Modulator working conditions were optimized and its separation power was demonstrated on the analysis of a lavender extract under an application of two orthogonal capillary column sets (nonpolar-polar vs. polar-nonpolar) and temperature program. The results were evaluated by two commercial software packages and discussed with respect to the identification compliance. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
de Jager, L S; Andrews, A R
2000-11-01
A novel, fast screening method for organochlorine pesticides (OCPs) in water samples has been developed. Total analysis time was less than 9 min, allowing 11 samples to be screened per hour. The relatively new technique of solvent microextraction (SME) was used to extract and preconcentrate the pesticides into a single drop of hexane. The use of a conventional carbon dioxide cryotrap was investigated for introduction of the extract onto a micro-bore (0.1 mm) capillary column for fast GC analysis. A pulsed-discharge electron capture detector was used which yielded selective and sensitive measurement of the pesticide peaks. Fast GC conditions were optimised and tested with the previously developed SME procedure. Calibration curves yielded good linearity and concentrations down to 0.25 ng mL-1 were detectable with RSD values ranging from 12.0 to 28% and LOD for most OCPs at 0.25 ng mL-1. Spiked river water samples were tested and using the developed screen we were able to differentiate between spiked samples and samples containing no OCPs.
Ono, Toshirou; Usami, Atsushi; Nakaya, Satoshi; Shinpuku, Hideto; Yonejima, Yasunori; Ikeda, Atsushi; Miyazawa, Mitsuo
2015-01-01
Volatile oils obtained from both the liquid medium after incubation (MAI) and liquid medium before incubation (MBI) during the cultivation process of Lactobacillus brevis were isolated by hydrodistillation (HD) and analyzed to determine the utility of the liquid waste. The composition of the volatile oils was analyzed by capillary gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS). In total, 55 and 36 compounds were detected in the volatile oils from MAI (MAI oil) and MBI (MBI oil), respectively. The principle components of MAI oil were N-containing compounds, including 2,3-dimethylpyrazine (16, 37.1 %), methylpyrazine (4, 17.1 %). The important aroma-active compounds in the oils were detected by GC-Olfactometry (GC-O), and their intensity of aroma were measured by aroma extract dilution analysis (AEDA). Expressly, pyrazine compounds were determined as key aroma components; in particular, 2,5-dimethylpyrazine and 2,3-dimethylpyrazine were the most primary aroma-active compound in MAI oil. These results imply that the waste medium after incubation of L. brevis may be utilized as a source of volatile oils.
Safaralie, Asghar; Fatemi, Shohreh; Sefidkon, Fatemeh
2008-02-08
The composition of essential oil extracted from Valeriana officinalis L. roots growing wild in Iran was studied by hydrodistillation and supercritical CO2 extraction. Forty-seven components representing 89.3% and 35 constituents varying from 86.1% to 95.1% of the oil obtained by hydrodistillation and supercritical CO2 were identified, respectively. The major components in the extracted oil from supercritical CO2 were isovaleric acid (18.7-41.8%), valerenic acid (8.2-11.8%), acetoxyvaleranone (5.6-9.6%), (Z)-valernyl acetate (4.5-6.5%), bornyl acetate (2.3-7.7%) and valerenol (3.7-5.2%), whereas by hydrodistillation were bornyl acetate (11.6%), valerenic acid (8.0%), (Z)-valernyl acetate (7.9%) and acetoxyvaleranone (7.6%). The analysis of the extracts was performed by capillary GC and GC/MS.
Improved Thermal Modulator for Gas Chromatography
NASA Technical Reports Server (NTRS)
Hasselbrink, Ernest Frederick, Jr.; Hunt, Patrick J.; Sacks, Richard D.
2008-01-01
An improved thermal modulator has been invented for use in a variant of gas chromatography (GC). The variant in question denoted as two-dimensional gas chromatography (2DGC) or GC-GC involves the use of three series-connected chromatographic columns, in the form of capillary tubes coated interiorly with suitable stationary phases (compounds for which different analytes exhibit different degrees of affinity). The two end columns are relatively long and are used as standard GC columns. The thermal modulator includes the middle column, which is relatively short and is not used as a standard GC column: instead, its temperature is modulated to affect timed adsorption and desorption of analyte gases between the two end columns in accordance with a 2DGC protocol.
Wang, Mei-Fei; Lian, Hong-Zhen; Mao, Li; Zhou, Jing-Ping; Gong, Hui-Juan; Qian, Bao-Yong; Fang, Yan; Li, Jie
2007-07-11
A capillary gas chromatographic (GC) method has been developed for the separation and determination of policosanol components extracted from rice bran wax. A Varian CP-sil 8 CB column was employed, and an oven temperature was programmed. Gas chromatography-mass spectrometry (GC-MS) was used to identify the composition of policosanol. Quantitative analysis was carried out by means of hydrogen flame ionization detector (FID) with dinonyl phthalate (DNP) as internal standard. The results indicated that the extract obtained by dry saponification has the highest contents of octacosanol and triacontanol among extracts by all used extraction methods including dry saponification, saponification in alcohol, saponification in water (neutralized and non-neutralized), and transesterification. Meanwhile, the GC-MS fingerprint of policosanol extracted by dry saponification has been established. Euclidean distance similarity calculation showed remarkable consistency of compositions and contents among 12 batches of policosanol from a rice bran wax variety. This protocol provided a rapid and feasible method for quality control of policosanol products.
Marques, André M; Fingolo, Catharina E; Kaplan, Maria Auxiliadora C
2017-11-01
High Speed Countercurrent Chromatography (HSCCC) technique was used for the preparative isolation of the major leishmanicidal compounds from the essential oils of Piper claussenianum species in Brazil. The essential oils from inflorescences of P. claussenianum were analyzed by GC-FID and GC-MS. The enantiomeric ratio of the major constituents of the P. claussenianum essential oils were determined using a Rt-DEXsm chiral capillary column by GC-FID analysis. It was found an enantiomeric excess of (+)-(E)-nerolidol in the leaves, and (+)-linalool and (+)-(E)-nerolidol in the inflorescences essential oil. The major volatile terpenes alcohols were isolated in preparative scale from inflorescences: linalool (320.0 mg) and nerolidol (95.0 mg) in high purity level. The HSCCC, a support-free liquid-liquid partition chromatographic technique, proved to be an effective and useful method for fast isolation and purification of hydrophobic and similarly structured bioactive components from essential oils of Piper species. Copyright © 2017 Elsevier Ltd. All rights reserved.
Improved quality control of [18F]fluoromethylcholine.
Nader, Michael; Reindl, Dietmar; Eichinger, Reinhard; Beheshti, Mohsen; Langsteger, Werner
2011-11-01
With respect to the broad application of [(18)F-methyl]fluorocholine (FCH), there is a need for a safe, but also efficient and convenient way for routine quality control of FCH. Therefore, a GC- method should be developed and validated which allows the simultaneous quantitation of all chemical impurities and residual solvents such as acetonitrile, ethanol, dibromomethane and N,N-dimethylaminoethanol. Analytical GC has been performed with a GC-capillary column Optima 1701 (50 m×0.32 mm), and a pre-column deactivated capillary column phenyl-Sil (10 m×0.32) in line with a flame ionization detector (FID) was used. The validation includes the following tests: specificity, range, accuracy, linearity, precision, limit of detection (LOD) and limit of quantitation (LOQ) of all listed substances. The described GC method has been successfully used for the quantitation of the listed chemical impurities. The specificity of the GC separation has been proven by demonstrating that the appearing peaks are completely separated from each other and that a resolution R≥1.5 for the separation of the peaks could be achieved. The specified range confirmed that the analytical procedure provides an acceptable degree of linearity, accuracy and precision. For each substance, a range from 2% to 120% of the specification limit could be demonstrated. The corresponding LOD values were determined and were much lower than the specification limits. An efficient and convenient GC method for the quality control of FCH has been developed and validated which meets all acceptance criteria in terms of linearity, specificity, precision, accuracy, LOD and LOQ. Copyright © 2011 Elsevier Inc. All rights reserved.
Essential oil composition of Dracocephalum kotschyi Boiss. from Iran.
Sonboli, Ali; Mirzania, Foroogh; Gholipour, Abbas
2018-06-06
Dracocephalum kotschyi is one of the medicinal and fragrant herbs that can be found in natural locations of mountainous areas. In this investigation the hydrodistilled essential oils obtained from aerial parts of two populations of D. kotschyi collected from Siahbisheh and Baladeh were analysed by capillary GC-FID and GC-MS. Essential oil analysis led to the identification of 48 compounds that represented 85.9 and 90.0% of the total oil compositions, respectively. As the major group of compounds, oxygenated monoterpens comprised 45.5 and 57.4% in the essential oils of compounds as the main group in the essential oils of Siahbisheh and Baladeh samples, respectively. Disagreement in the major contents of the essential oils of these two samples may be ascribed to differences in the ecological, climatic and genetically factors.
Sterol Profile for Natural Juices Authentification by GC-MS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Culea, M.
A GC-MS analytical method is described for some natural juices analysis. The fingerprint of sterols was used to characterize the natural juice. A rapid liquid-liquid extraction method was used. The sterols were separated on a Rtx-5MS capillary column, 15mx0.25mm, 0.25{mu}m film thickness, in a temperature program from 50 deg. C for 1 min, then ramped at 15 deg. C/min to 300 deg. C and held for 15 min. Identification of sterols and their patterns were used for juice characterization. The sterol profile is a useful approach for confirming the presence of juices of orange, grapefruit, pineapple and passion fruit inmore » compounded beverages and for detecting of adulteration of fruit juices.« less
ANALYSIS OF GLYCANS DERIVED FROM GLYCOCONJUGATES BY CAPILLARY ELECTROPHORESIS-MASS SPECTROMETRY
Mechref, Yehia
2012-01-01
The high structural variation of glycan derived from glycoconjugates, which substantially increases with the molecular size of a protein, contributes to the complexity of glycosylation patterns commonly associated with glycoconjugates. In the case of glycoproteins, such variation originates from the multiple glycosylation sites of proteins and the number of glycan structures associated with each site (microheterogeneity). The ability to comprehensively characterize highly complex mixture of glycans has been analytically stimulating and challenging. Although the most powerful mass spectrometric (MS) and tandem MS techniques are capable of providing a wealth of structural information, they are still not able to readily identify isomeric glycan structures without high order tandem MS (MSn). The analysis of isomeric glycan structures has been attained using several separation methods, including high-pH anion exchange chromatography (HPAEC), hydrophilic interaction chromatography (HILIC) and gas chromatography (GC). However, capillary electrophoresis (CE) and microfluidics capillary electrophoresis (MCE) offer high separation efficiency and resolutions, allowing the separation of closely related glycan structures. Therefore, interfacing CE and MCE to MS is a powerful analytical approach, allowing potentially comprehensive and sensitive analysis of complex glycan samples. This review describes and discusses the utility of different CE and MCE approaches in the structural characterization of glycoproteins and the feasibility of interfacing these approaches to mass spectrometry. PMID:22180203
Fan, Wen; Almirall, José
2014-03-01
A novel geometry configuration based on sorbent-coated glass microfibers packed within a glass capillary is used to sample volatile organic compounds, dynamically, in the headspace of an open system or in a partially open system to achieve quantitative extraction of the available volatiles of explosives with negligible breakthrough. Air is sampled through the newly developed sorbent-packed 2 cm long, 2 mm diameter capillary microextraction of volatiles (CMV) and subsequently introduced into a commercially available thermal desorption probe fitted directly into a GC injection port. A sorbent coating surface area of ∼5 × 10(-2) m(2) or 5,000 times greater than that of a single solid-phase microextraction (SPME) fiber allows for fast (30 s), flow-through sampling of relatively large volumes using sampling flow rates of ∼1.5 L/min. A direct comparison of the new CMV extraction to a static (equilibrium) SPME extraction of the same headspace sample yields a 30 times improvement in sensitivity for the CMV when sampling nitroglycerine (NG), 2,4-dinitrotoluene (2,4-DNT), and diphenylamine (DPA) in a mixture containing a total mass of 500 ng of each analyte, when spiked into a liter-volume container. Calibration curves were established for all compounds studied, and the recovery was determined to be ∼1 % or better after only 1 min of sampling time. Quantitative analysis is also possible using this extraction technique when the sampling temperature, flow rate, and time are kept constant between calibration curves and the sample.
Orton, Dennis J; Boyd, Jessica M; Affleck, Darlene; Duce, Donna; Walsh, Warren; Seiden-Long, Isolde
2016-01-01
Clinical analysis of volatile alcohols (i.e. methanol, ethanol, isopropanol, and metabolite acetone) and ethylene glycol (EG) generally employs separate gas chromatography (GC) methods for analysis. Here, a method for combined analysis of volatile alcohols and EG is described. Volatile alcohols and EG were extracted with 2:1 (v:v) acetonitrile containing internal standards (IS) 1,2 butanediol (for EG) and n-propanol (for alcohols). Samples were analyzed on an Agilent 6890 GC FID. The method was evaluated for precision, accuracy, reproducibility, linearity, selectivity and limit of quantitation (LOQ), followed by correlation to existing GC methods using patient samples, Bio-Rad QC, and in-house prepared QC material. Inter-day precision was from 6.5-11.3% CV, and linearity was verified from down to 0.6mmol/L up to 150mmol/L for each analyte. The method showed good recovery (~100%) and the LOQ was calculated to be between 0.25 and 0.44mmol/L. Patient correlation against current GC methods showed good agreement (slopes from 1.03-1.12, and y-intercepts from 0 to 0.85mmol/L; R(2)>0.98; N=35). Carryover was negligible for volatile alcohols in the measuring range, and of the potential interferences tested, only toluene and 1,3 propanediol interfered. The method was able to resolve 2,3 butanediol, diethylene glycol, and propylene glycol in addition to the peaks quantified. Here we describe a simple procedure for simultaneous analysis of EG and volatile alcohols that comes at low cost and with a simple liquid-liquid extraction requiring no derivitization to obtain adequate sensitivity for clinical specimens. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Byers, John A
2004-05-30
Heating of chromatographic columns, transfer lines, and other devices is often required in neuroscience research. For example, volatile compounds passing through a capillary column of a gas chromatograph (GC) can be split, with half exiting the instrument through a heated transfer line to an insect antenna or olfactory sensillum for electroantennographic detector (GC-EAD) recordings. The heated transfer line is used to prevent condensation of various chemicals in the capillary that would otherwise occur at room temperature. Construction of such a transfer line heater is described using (80/20%) nickel-chromium heating wire wrapped in a helical coil and powered by a 120/220 V ac rheostat. Algorithms were developed in a computer program to estimate the voltage at which a rheostat should be set to obtain the desired heater temperature for a specific coil. The coil attributes (radius, width, number of loops, or length of each loop) are input by the user, as well as AWG size of heating wire and desired heater temperature. The program calculates total length of wire in the helix, resistance of the wire, amperage used, and the voltage to set the rheostat. A discussion of semiochemical isolation methods using the GC-EAD and bioassays is presented.
Poster, Dianne L.; Schantz, Michele M.; Leigh, Stefan D.; Wise, Stephen A.
2004-01-01
Six Standard Reference Materials (SRMs®) have been prepared by the National Institute of Standards and Technology (NIST) for the determination of PCBs as different Aroclor mixtures in methanol. Six additional SRMs of the same Aroclors in transformer oil have also been prepared. Specifically, solutions of Aroclors 1016, 1232, 1242, 1254, and 1260 have been gravimetrically prepared (individually) in methanol and transformer oil, mixed, and transferred to amber glass ampoules in approximately 1.2 mL aliquots. Gas chromatography with electron capture detection (GC-ECD) has been used to verify the gravimetric data for each solution and transformer oil SRM. Liquid chromatography was used for the isolation of the Aroclors from the transformer oil SRMs prior to GC-ECD analysis. Separate calibration solutions and oils were prepared with Aroclor levels similar to those in each methanol solution and transformer oil SRM and were processed alongside the samples. The GC-ECD response of each Aroclor was monitored relative to internal standards that were added to the complex mixtures for quantification. The gravimetric concentrations of Aroclors 1242 and 1254 in methanol were also examined by the same method of analysis (GC-ECD) using several different sources of Aroclors and two different capillary GC columns: a 5 % phenyl methylpolysiloxane phase and a relatively non-polar phase. The preparation of the materials, the gas chromatographic results, and the certified concentration values for each Aroclor SRM are described in this paper. PMID:27366608
Ilias, Yara; Bieri, Stefan; Christen, Philippe; Veuthey, Jean-Luc
2006-08-01
By its simplicity and rapidity, solid-phase microextraction (SPME) appears as an interesting alternative for sample introduction in fast gas chromatography (fast GC). This combination depends on numerous parameters affecting the desorption step (i.e., the release of compounds from the SPME fiber coating to the GC column). In this study, different liner diameters, injection temperatures, and gas flow rates are evaluated to accelerate the thermal desorption process in the injection port. This process is followed with real-time direct coupling a split/splitless injector to a mass spectrometer by means of a short capillary. It is shown that an effective, quantitative, and rapid transfer of cocaine (COC) and cocaethylene (CE) is performed with a 0.75-mm i.d. liner, at 280 degrees C and 4 mL/min gas flow rate. The 7-microm polydimethylsiloxane (PDMS) coating is selected for combination with fast GC because the 100-microm PDMS fiber presents some limitations caused by fiber bleeding. Finally, the developed SPME-fast GC method is applied to perform in less than 5 min, the quantitation of COC extracted from coca leaves by focused microwave-assisted extraction. An amount of 7.6 +/- 0.5 mg of COC per gram of dry mass is found, which is in good agreement with previously published results.
2003-11-01
klick on File TL-03- uGC -Model.xls Model 2. Determination of Peak Capacity for 0.1 < k’ < 5. This tool was intended to help with the determination of peak...dependent on the agreed k’ range, i.e. the associated boiling point range. Double-klick on File TL-03- uGC -Model.xls Model 3. Estimation of the Fraction...available today on the market .6 Figure 6 is a 2 second GC chromatogram of 7 test compounds using the 100 micron square capillary column (see Figure 4
Acrylamide: formation, occurrence in food products, detection methods, and legislation.
Arvanitoyannis, Ioannis S; Dionisopoulou, Niki
2014-01-01
This review aims at summarizing the most recent updates in the field of acrylamide (AA) formation (mechanism, conditions) and the determination of AA in a number of foods (fried or baked potatoes, chips, coffee, bread, etc). The methods applied for AA detection [Capillary Electrophoresis-Mass Spectrometry (CE-MS), Liquid Chromatography-Mass Spectrometry (LC-MS), Non-Aqueous Capillary Electrophoresis (NACE), High Performance Liquid Chromatography-Mass Spectrometry (HPLC-MS), Pressurized Fluid Extraction (PFE), Matrix Solid-Phase Dispersion (MSPD), Gas Chromatography-Mass Spectrometry (GC-MS), Solid-Phase MicroExtraction-Gas Chromatography (SPME-GC), Enzyme Linked Immunosorbent Assay (ELISA), and MicroEmulsion ElectroKinetic Chromatography (MEEKC) are presented and commented. Several informative figures and tables are included to show the effect of conditions (temperature, time) on the AA formation. A section is also included related to AA legislation in EU and US.
Bicchi, Carlo; Liberto, Erica; Cagliero, Cecilia; Cordero, Chiara; Sgorbini, Barbara; Rubiolo, Patrizia
2008-11-28
The analysis of complex real-world samples of vegetable origin requires rapid and accurate routine methods, enabling laboratories to increase sample throughput and productivity while reducing analysis costs. This study examines shortening enantioselective-GC (ES-GC) analysis time following the approaches used in fast GC. ES-GC separations are due to a weak enantiomer-CD host-guest interaction and the separation is thermodynamically driven and strongly influenced by temperature. As a consequence, fast temperature rates can interfere with enantiomeric discrimination; thus the use of short and/or narrow bore columns is a possible approach to speeding-up ES-GC analyses. The performance of ES-GC with a conventional inner diameter (I.D.) column (25 m length x 0.25 mm I.D., 0.15 microm and 0.25 microm d(f)) coated with 30% of 2,3-di-O-ethyl-6-O-tert-butyldimethylsilyl-beta-cyclodextrin in PS-086 is compared to those of conventional I.D. short column (5m length x 0.25 mm I.D., 0.15 microm d(f)) and of different length narrow bore columns (1, 2, 5 and 10 m long x 0.10 mm I.D., 0.10 microm d(f)) in analysing racemate standards of pesticides and in the flavour and fragrance field and real-world-samples. Short conventional I.D. columns gave shorter analysis time and comparable or lower resolutions with the racemate standards, depending mainly on analyte volatility. Narrow-bore columns were tested under different analysis conditions; they provided shorter analysis time and resolutions comparable to those of conventional I.D. ES columns. The narrow-bore columns offering the most effective compromise between separation efficiency and analysis time are the 5 and 2m columns; in combination with mass spectrometry as detector, applied to lavender and bergamot essential oil analyses, these reduced analysis time by a factor of at least three while separation of chiral markers remained unaltered.
Sohn, Elliott H; van Dijk, Hille W; Jiao, Chunhua; Kok, Pauline H B; Jeong, Woojin; Demirkaya, Nazli; Garmager, Allison; Wit, Ferdinand; Kucukevcilioglu, Murat; van Velthoven, Mirjam E J; DeVries, J Hans; Mullins, Robert F; Kuehn, Markus H; Schlingemann, Reinier Otto; Sonka, Milan; Verbraak, Frank D; Abràmoff, Michael David
2016-05-10
Diabetic retinopathy (DR) has long been recognized as a microvasculopathy, but retinal diabetic neuropathy (RDN), characterized by inner retinal neurodegeneration, also occurs in people with diabetes mellitus (DM). We report that in 45 people with DM and no to minimal DR there was significant, progressive loss of the nerve fiber layer (NFL) (0.25 μm/y) and the ganglion cell (GC)/inner plexiform layer (0.29 μm/y) on optical coherence tomography analysis (OCT) over a 4-y period, independent of glycated hemoglobin, age, and sex. The NFL was significantly thinner (17.3 μm) in the eyes of six donors with DM than in the eyes of six similarly aged control donors (30.4 μm), although retinal capillary density did not differ in the two groups. We confirmed significant, progressive inner retinal thinning in streptozotocin-induced "type 1" and B6.BKS(D)-Lepr(db)/J "type 2" diabetic mouse models on OCT; immunohistochemistry in type 1 mice showed GC loss but no difference in pericyte density or acellular capillaries. The results suggest that RDN may precede the established clinical and morphometric vascular changes caused by DM and represent a paradigm shift in our understanding of ocular diabetic complications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mitchell, S.C.; Bartle, K.D.; Holden, K.M.L.
1994-12-31
A series of heteroatom-rich coal and coal-derived liquids have been analysed using gas chromatography (GC) in combination with three different element-selective detectors. Selected chromatograms, including a supercritical extract (Mequinenza lignite) and aromatic fractions isolated from coal tar pitch samples are presented. In each case a series of sulphur- and/or nitrogen-containing compounds have been identified using either flame photometric detection (GC/FID/FPD) or nitrogen-phosphorous detection (GC/FID/NPD) and the information compared with that obtained from a GC coupled to an atomic emission detector (GC-AED). Preliminary results have demonstrated the relative response characteristics of each detector and their respective ability to acquire qualitative andmore » quantitative information in interfering background matrices. Further, due to the unique capabilities of GC-AED, a number of dual heteroatomic (sulphur-oxygen and nitrogen-oxygen) compounds have been identified.« less
Ono, Toshirou; Yonejima, Yasunori; Ikeda, Atsushi; Kashima, Yusei; Nakaya, Satoshi; Miyazawa, Mitsuo
2014-01-01
Volatile oils obtained from both the liquid medium after incubation (MAI) and liquid medium before incubation (MBI) in the cultivation process of Lactobacillus acidophilus were isolated by hydrodistillation (HD) and analyzed to investigate the utility of the liquid waste. The composition of the volatile oils was analyzed by capillary gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS). In total, 46 and 19 compounds were detected in the volatile oils from MAI (MAI oil) and MBI (MBI oil), respectively. The principle components of MAI oil were fatty acids, including pentanoic acid (12.75%), heptanoic acid (14.05%), and nonanoic acid (14.04%). The important aroma-active compounds in the oils were detected by GC-MS/Olfactometry (GC-O), and their intensity of aroma were measured by aroma extraction dilution analysis (AEDA). Pyrazines were determined as key aroma components; in particular, 2-ethyl-5-methylpyrazine was the most primary aroma-active compound in MAI oil. In addition, as the characteristic aroma-active compounds, 3-(methylthio)-propanal, trimethylpyrazine, and pentanoic acid were also detected in MAI oil. These results imply that the waste medium after incubation of L. acidophilus may be utilized as a source of volatile oils.
Taguchi, Vince Y; Nieckarz, Robert J; Clement, Ray E; Krolik, Stefan; Williams, Robert
2010-11-01
The feasibility of utilizing a gas chromatograph-tandem quadrupole-Fourier transform ion cyclotron resonance mass spectrometer (GC-MS/MS-FTICRMS) to analyze chlorinated-dioxins/furans (CDDs/CDFs) and mixed halogenated dioxins/furans (HDDs/HDFs) was investigated by operating the system in the GC-FTICRMS mode. CDDs/CDFs and mixed HDDs/HDFs could be analyzed at 50,000 to 100,000 resolving power (RP) on the capillary gas chromatographic time scale. Initial experiments demonstrated that 1 pg of 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) and 5 pg of 2-bromo-3,7,8-trichlorodibenzo-p-dioxin (BTrCDD) could be detected. The feasibility of utilizing an FTICRMS for screening of CDDs/CDFs, HDDs/HDFs and related compounds was also investigated by analyzing an extract from vegetation exposed to fall-out from an industrial fire. CDDs/CDFs, chlorinated pyrenes and chlorinated tetracenes could be detected from a Kendrick plot analysis of the ultrahigh resolution mass spectra. Mass accuracies were of the order of 0.5 ppm on standards with external mass calibration and 1 ppm on a sample with internal mass calibration. Copyright © 2010 American Society for Mass Spectrometry. Published by Elsevier Inc. All rights reserved.
Calva, James; Bec, Nicole; Gilardoni, Gianluca; Larroque, Christian; Cartuche, Luis; Bicchi, Carlo; Montesinos, José Vinicio
2017-10-31
This study investigated the chemical composition, physical proprieties, biological activity, and enantiomeric analysis of the essential oil from the aerial parts of Niphogeton dissecta (culantrillo del cerro) from Ecuador, obtained by steam distillation. The qualitative and quantitative analysis of the essential oil was realized by gas chromatographic and spectroscopic techniques (GC-MS and GC-FID). Acorenone B was identified by GC-MS and NMR experiments. The enantiomeric distribution of some constituents has been assessed by enantio-GC through the use of a chiral cyclodextrin-based capillary column. We identified 41 components that accounted for 96.46% of the total analyzed, the major components were acorenone B (41.01%) and (E)-β-ocimene (29.64%). The enantiomeric ratio of (+)/(-)-β-pinene was 86.9:13.1, while the one of (+)/(-)-sabinene was 80.9:19.1. The essential oil showed a weak inhibitory activity, expressed as Minimal Inhibitory Concentration (MIC), against Enterococcus faecalis (MIC 10 mg/mL) and Staphylococcus aureus (MIC 5 mg/mL). Furthermore, it inhibited butyrylcholinesterase with an IC 50 value of 11.5 μg/mL. Pure acorenone B showed inhibitory activity against both acetylcholinesterase and butyrylcholinesterase, with IC 50 values of 40.8 μg/mL and 10.9 μg/mL, respectively.
Calva, James; Bec, Nicole; Gilardoni, Gianluca; Larroque, Christian; Cartuche, Luis; Bicchi, Carlo; Montesinos, José Vinicio
2017-01-01
This study investigated the chemical composition, physical proprieties, biological activity, and enantiomeric analysis of the essential oil from the aerial parts of Niphogeton dissecta (culantrillo del cerro) from Ecuador, obtained by steam distillation. The qualitative and quantitative analysis of the essential oil was realized by gas chromatographic and spectroscopic techniques (GC-MS and GC-FID). Acorenone B was identified by GC-MS and NMR experiments. The enantiomeric distribution of some constituents has been assessed by enantio-GC through the use of a chiral cyclodextrin-based capillary column. We identified 41 components that accounted for 96.46% of the total analyzed, the major components were acorenone B (41.01%) and (E)-β-ocimene (29.64%). The enantiomeric ratio of (+)/(−)-β-pinene was 86.9:13.1, while the one of (+)/(−)-sabinene was 80.9:19.1. The essential oil showed a weak inhibitory activity, expressed as Minimal Inhibitory Concentration (MIC), against Enterococcus faecalis (MIC 10 mg/mL) and Staphylococcus aureus (MIC 5 mg/mL). Furthermore, it inhibited butyrylcholinesterase with an IC50 value of 11.5 μg/mL. Pure acorenone B showed inhibitory activity against both acetylcholinesterase and butyrylcholinesterase, with IC50 values of 40.8 μg/mL and 10.9 μg/mL, respectively. PMID:29088082
Hayward, Douglas G; Wong, Jon W; Zhang, Kai; Chang, James; Shi, Feng; Banerjee, Kaushik; Yang, Paul
2011-01-01
Five different mass spectrometers interfaced to GC or LC were evaluated for their application to targeted and nontargeted screening of pesticides in two foods, spinach and ginseng. The five MS systems were capillary GC/MS/MS, GC-high resolution time-of-flight (GC/HR-TOF)-MS, TOF-MS interfaced with a comprehensive multidimensional GC (GCxGC/TOF-MS), an MS/MS ion trap hybrid mass (qTrap) system interfaced with an ultra-performance liquid chromatograph (UPLC-qTrap), and UPLC interfaced to an orbital trap high resolution mass spectrometer (UPLC/Orbitrap HR-MS). Each MS system was tested with spinach and ginseng extracts prepared through a modified quick, easy, cheap, effective, rugged, and safe (QuEChERS) procedure. Each matrix was fortified at 10 and 50 ng/g for spinach or 25 and 100 ng/g for ginseng with subsets of 486 pesticides, isomers, and metabolites representing most pesticide classes. HR-TOF-MS was effective in a targeted search for characteristic accurate mass ions and identified 97% of 170 pesticides in ginseng at 25 ng/g. A targeted screen of either ginseng or spinach found 94-95% of pesticides fortified for analysis at 10 ng/g with GC/MS/MS or LC/MS/MS using multiple reaction monitoring (MRM) procedures. Orbitrap-MS successfully found 89% of 177 fortified pesticides in spinach at 25 ng/g using a targeted search of accurate mass pseudomolecular ions in the positive electrospray ionization mode. A comprehensive GCxGC/TOF-MS system provided separation and identification of 342 pesticides and metabolites in a single 32 min acquisition with standards. Only 67 or 81% of the pesticides were identified in ginseng and spinach matrixes at 25 ng/g or 10 ng/g, respectively. MS/MS or qTrap-MS operated in the MRM mode produced the lowest false-negative rates, at 10 ng/g. Improvements to instrumentation, methods, and software are needed for efficient use of nontargeted screens in parallel with triple quadrupole MS.
Kang, Ju Hui; Jung, Hyun Jeong; Jung, Mun Yhung
2016-08-31
We developed a new fast and selective analytical method for the determination of inorganic arsenic (iAs) in rice by a gas chromatography - tandem mass spectrometry (GC-MS/MS) in combination with one step derivatization of inorganic arsenic (iAs) with British Anti-Lewsite (BAL). Two step derivatization of iAs with BAL has been previously performed for the GC-MS analysis. In this paper, the quantitative one step derivatization condition was successfully established. The GC-MS/MS was carried out with a short nonpolar capillary column (0.25 mm × 10 m) under the conditions of fast oven temperature ramp rate (4 °C/s) and high linear velocity (108.8 cm/s) of the carrier gas. The established GC-MS/MS method showed an excellent linearity (r(2) > 0.999) in a tested range (0.2-100.0 μg L(-1)), ultra-low limit of detection (LOD, 0.08 pg), and high precision and accuracy. The GC-MS/MS technique showed far greater selectivity (22.5 fold higher signal to noise ratio in rice sample) on iAs than GC-MS method. The gas chromatographic running time was only 2.5 min with the iAs retention time of 1.98 min. The established method was successfully applied to quantify the iAs contents in polished rice. The mean iAs content in the Korean polished rice (n = 27) was 66.1 μg kg(-1) with the range of 37.5-125.0 μg kg(-1). This represents the first report on the GC-tandem mass spectrometry in combination with the one step derivatization with BAL for the iAs speciation in rice. This GC-MS/MS method would be a simple, useful and reliable measure for the iAs analysis in rice in the laboratories in which the expensive and element specific HPLC-ICP-MS is not available. Copyright © 2016 Elsevier B.V. All rights reserved.
Grossi, Paula; Olivares, Igor R B; de Freitas, Diego R; Lancas, Fernando M
2008-10-01
A methodology to analyze organochlorine pesticides (OCPs) in water samples has been accomplished by using headspace stir bar sorptive extraction (HS-SBSE). The bars were in house coated with a thick film of PDMS in order to properly work in the headspace mode. Sampling was done by a novel HS-SBSE system whereas the analysis was performed by capillary GC coupled mass spectrometric detection (HS-SBSE-GC-MS). The extraction optimization, using different experimental parameters has been established by a standard equilibrium time of 120 min at 85 degrees C. A mixture of ACN/toluene as back extraction solvent promoted a good performance to remove the OCPs sorbed in the bar. Reproducibility between 2.1 and 14.8% and linearity between 0.96 and 1.0 were obtained for pesticides spiked in a linear range between 5 and 17 ng/g in water samples during the bar evaluation.
Piryaei, Marzieh
2018-01-01
Zn/Al layered double hydroxide (LDH) films were fabricated in situ with anodic aluminium oxide aluminium as both the substrate and the sole aluminium source by means of urea hydrolysis. Headspace solid phase microextraction using LDH fibre in combination with capillary GC-MS was utilised as a monitoring technique for the collection and detection of the volatile compounds of Origanum vulgare. Experimental parameters, including the sample weight, microwave power, extraction time and humidity effect, were examined and optimised.
Du, Xin; Ren, YongLin; Beckett, Stephen J
2016-01-01
The rapid detection of pesticide residues in wheat has become a top food security priority. A solvent-free headspace solid-phase microextraction (HS-SPME) has been evaluated for rapid screening of organophosphorus pesticide (OPP) residues in wheat with high sensitivity. Individual wheat samples (1.7 g), spiked with 10 OPPs, were placed in a 4 mL sealed amber glass vial and heated at 60°C for 45 min. During this time, the OPP residues were extracted with a 50 μm/30 μm divinylbenzene (DVB)/carboxen (CAR)/plasma desorption mass spectroscopy polydimethylsiloxane (PDMS) fiber from the headspace above the sample. The fiber was then removed and injected into the GC injection port at 250°C for desorption of the extracted chemicals. The multiple residues were identified by a GC mass spectrometer detector (GC-MSD) and quantified with a GC flame photometric detector (GC-FPD). Seven spiked levels of 10 OPPs on wheat were analyzed. The GC responses for a 50 μm/30 μm DVB/CAR/PDMS fiber increased with increasing spiking levels, yielding significant (R(2) > 0.98) linear regressions. The lowest LODs of the multiple pesticide standards were evaluated under the conditions of the validation study in a range of levels from 0 (control) to 100 ng of pesticide residue per g of wheat that separated on a low-polar GC capillary column (Agilent DB-35UI). The results of the HS-SPME method were compared with the QuEChERS AOAC 2007.01 method and they showed several advantages over the latter. These included improved sensitivity, selectivity, and simplicity.
Giuliani, N; Beyer, J; Augsburger, M; Varlet, V
2015-03-01
Drug abuse is a widespread problem affecting both teenagers and adults. Nitrous oxide is becoming increasingly popular as an inhalation drug, causing harmful neurological and hematological effects. Some gas chromatography-mass spectrometry (GC-MS) methods for nitrous oxide measurement have been previously described. The main drawbacks of these methods include a lack of sensitivity for forensic applications; including an inability to quantitatively determine the concentration of gas present. The following study provides a validated method using HS-GC-MS which incorporates hydrogen sulfide as a suitable internal standard allowing the quantification of nitrous oxide. Upon analysis, sample and internal standard have similar retention times and are eluted quickly from the molecular sieve 5Å PLOT capillary column and the Porabond Q column therefore providing rapid data collection whilst preserving well defined peaks. After validation, the method has been applied to a real case of N2O intoxication indicating concentrations in a mono-intoxication. Copyright © 2015 Elsevier B.V. All rights reserved.
Rodríguez-Gómez, R; Zafra-Gómez, A; Camino-Sánchez, F J; Ballesteros, O; Navalón, A
2014-07-04
In the present work, two specific, accurate and sensitive methods for the determination of endocrine disrupting chemicals (EDCs) in human breast milk are developed and validated. Bisphenol A and its main chlorinated derivatives, five benzophenone-UV filters and four parabens were selected as target analytes. The method involves a stir-bar sorptive extraction (SBSE) procedure followed by a solvent desorption prior to GC-MS/MS or UHPLC-MS/MS analysis. A derivatization step is also necessary when GC analysis is performed. The GC column used was a capillary HP-5MS with a run time of 26min. For UHPLC analysis, the stationary phase was a non-polar Acquity UPLC(®) BEH C18 column and the run time was 10min. In both cases, the analytes were detected and quantified using a triple quadrupole mass spectrometer (QqQ). Quality parameters such as linearity, accuracy (trueness and precision), sensitivity and selectivity were examined and yielded good results. The limits of quantification (LOQs) ranged from 0.3 to 5.0ngmL(-1) for GC and from 0.2 to 1.0ngmL(-1) for LC. The relative standard deviation (RSD) was lower than 15% and the recoveries ranged from 92 to 114% in all cases, being slightly unfavorable the results obtained with LC. The methods were satisfactorily applied for the determination of target compounds in human milk samples from 10 randomly selected women. Copyright © 2014 Elsevier B.V. All rights reserved.
Mendoza, Laura González; González-Álvarez, Jaime; Gonzalo, Carla Fernández; Arias-Abrodo, Pilar; Altava, Belén; Luis, Santiago V; Burguete, Maria Isabel; Gutiérrez-Álvarez, María Dolores
2015-10-01
A Gas Chromatography (GC) method has been developed for the separation and characterization of the different fatty acids in anhydrous milk fat (AMF) by means of an ionic liquid stationary phase, characterized by a monocationic imidazolium salt derived from L-phenylalanine. The inner surface of a fused silica capillary column was modified using this ionic liquid functionality and 3-aminopropyldiethoxymethyl silane. This coated GC column, which exhibited good thermal stability (270°C) and good efficiency (2700 plates/m), has been characterized using the Abraham solvation parameter model. The intra-day and inter-day precision of the method have been evaluated, obtaining relative standard deviations (RSD) from 0.99% to 4.0% and from 2.8% to 9.2%, respectively. Furthermore, recoveries from 90% and 99% have been achieved. Copyright © 2015 Elsevier B.V. All rights reserved.
GLOBAL EFFECTS OF VARIOUS SOIL TREATMENTS ON TRANSFORMATIONS OF CHIRAL PESTICIDES
Many pesticides and other organic pollutants are chiral, and their enantiomers exhibit differences in biological properties, including rates of microbial degradation. We have measured by chiral GC and capillary electrophoresis the enantioselectivity of biodegradation of three pe...
GC/IR computer-aided identification of anaerobic bacteria
NASA Astrophysics Data System (ADS)
Ye, Hunian; Zhang, Feng S.; Yang, Hua; Li, Zhu; Ye, Song
1993-09-01
A new method was developed to identify anaerobic bacteria by using pattern recognition. The method is depended on GC / JR data. The system is intended for use as a precise rapid and reproduceable aid in the identification of unknown isolates. Key Words: Anaerobic bacteria Pattern recognition Computeraided identification GC / JR 1 . TNTRODUCTTON A major problem in the field of anaerobic bacteriology is the difficulty in accurately precisely and rapidly identifying unknown isolates. Tn the proceedings of the Third International Symposium on Rapid Methods and Automation in Microbiology C. M. Moss said: " Chromatographic analysis is a new future for clinical microbiology" . 12 years past and so far it seems that this is an idea whose time has not get come but it close. Now two major advances that have brought the technology forword in terms ofmaking it appropriate for use in the clinical laboratory can aldo be cited. One is the development and implementation of fused silica capillary columns. In contrast to packed columns and those of'' greater width these columns allow reproducible recovery of hydroxey fatty acids with the same carbon chain length. The second advance is the efficient data processing afforded by modern microcomputer systems. On the other hand the practical steps for sample preparation also are an advance in the clinical laboratory. Chromatographic Analysis means mainly of analysis of fatty acids. The most common
Hinckley, D.A.; Bidleman, T.F.; Foreman, W.T.; Tuschall, J.R.
1990-01-01
Vapor pressures for nonpolar and moderately polar organochlorine, pyrethroid, and organophosphate insecticides, phthalate esters, and organophosphate flame retardants were determined by capillary gas chromatography (GC). Organochlorines and polycyclic aromatic hydrocarbons with known liquid-phase vapor pressures (P??L) (standard compounds) were chromatographed along with two reference compounds n-C20 (elcosane) and p,p???-DDT on a 1.0-m-long poly(dimethylsiloxane) bonded-phase (BP-1) column to determine their vapor pressures by GC (P??GC). A plot of log P??L vs log P??GC for standard compounds was made to establish a correlation between measured and literature values, and this correlation was then used to compute P??L of test compounds from their measured P??GC. P??L of seven major components of technical chlordane, endosulfan and its metabolites, ??-hexachlorocyclohexane, mirex, and two components of technical toxaphene were determined by GC. This method provides vapor pressures within a factor of 2 of average literature values for nonpolar compounds, similar to reported interlaboratory precisions of vapor pressure determinations. GC tends to overestimate vapor pressures of moderately polar compounds. ?? 1990 American Chemical Society.
Alhooshani, Khalid; Kim, Tae-Young; Kabir, Abuzar; Malik, Abdul
2005-01-07
A novel zirconia-based hybrid organic-inorganic sol-gel coating was developed for capillary microextraction (CME) (in-tube SPME). High degree of chemical inertness inherent in zirconia makes it very difficult to covalently bind a suitable organic ligand to its surface. In the present work, this problem was addressed from a sol-gel chemistry point of view. Principles of sol-gel chemistry were employed to chemically bind a hydroxy-terminated silicone polymer (polydimethyldiphenylsiloxane, PDMDPS) to a sol-gel zirconia network in the course of its evolution from a highly reactive alkoxide precursor undergoing controlled hydrolytic polycondensation reactions. A fused silica capillary was filled with a properly designed sol solution to allow for the sol-gel reactions to take place within the capillary for a predetermined period of time (typically 15-30 min). In the course of this process, a layer of the evolving hybrid organic-inorganic sol-gel polymer got chemically anchored to the silanol groups on the capillary inner walls via condensation reaction. At the end of this in-capillary residence time, the unbonded part of the sol solution was expelled from the capillary under helium pressure, leaving behind a chemically bonded sol-gel zirconia-PDMDPS coating on the inner walls. Polycyclic aromatic hydrocarbons, ketones, and aldehydes were efficiently extracted and preconcentrated from dilute aqueous samples using sol-gel zirconia-PDMDPS coated capillaries followed by thermal desorption and GC analysis of the extracted solutes. The newly developed sol-gel hybrid zirconia coatings demonstrated excellent pH stability, and retained the extraction characteristics intact even after continuous rinsing with a 0.1 M NaOH solution for 24 h. To our knowledge, this is the first report on the use of a sol-gel zirconia-based hybrid organic-inorganic coating as an extraction medium in solid phase microextraction (SPME).
FIELD ANALYTICAL SCREENING PROGRAM: PCP METHOD - INNOVATIVE TECHNOLOGY EVALUATION REPORT
The Field Analytical Screening Program (FASP) pentachlorophenol (PCP) method uses a gas chromatograph (GC) equipped with a megabore capillary column and flame ionization detector (FID) and electron capture detector (ECD) to identify and quantify PCP. The FASP PCP method is design...
Niwa, O; Horiuchi, T; Torimitsu, K
1997-01-01
A small volume L-glutamate online sensor was developed in order to monitor changes in the local concentration of L-glutamate released from cultured nerve cells. Syringe pump in the suction mode is used to sample extracellular fluid continuously from a glass micro-capillary and the concentration of L-glutamate can be determined by using a glassy carbon (GC) electrode modified with an Os-polyvinylpyridine mediator bottom film containing horseradish peroxidase and a bovine serum albumin top layer containing L-glutamate oxidase. The overall efficiency of L-glutamate detection with a sensor is 71% under optimum conditions due to an efficient enzymatic reaction at the modified electrode in the thin layer radial flow cell. As a result, we achieved a detection limit of 7-15 nM and a linear range of 50 nM to 10 microM. In an in vitro experiment, the extracellular fluid near a particular nerve cell can be sampled with this micro-pipet and continuously introduced into the modified GC electrode in the radial flow cell via suction provided by a syringe pump. The nerve cells are stimulated by the KCl in a glass capillary and the L-glutamate concentration change can be monitored by changing the distance between the sampling pipet and the nerve cells.
Yoshida, Masaru; Hatano, Naoya; Nishiumi, Shin; Irino, Yasuhiro; Izumi, Yoshihiro; Takenawa, Tadaomi; Azuma, Takeshi
2012-01-01
Recently, metabolome analysis has been increasingly applied to biomarker detection and disease diagnosis in medical studies. Metabolome analysis is a strategy for studying the characteristics and interactions of low molecular weight metabolites under a specific set of conditions and is performed using mass spectrometry and nuclear magnetic resonance spectroscopy. There is a strong possibility that changes in metabolite levels reflect the functional status of a cell because alterations in their levels occur downstream of DNA, RNA, and protein. Therefore, the metabolite profile of a cell is more likely to represent the current status of a cell than DNA, RNA, or protein. Thus, owing to the rapid development of mass spectrometry analytical techniques metabolome analysis is becoming an important experimental method in life sciences including the medical field. Here, we describe metabolome analysis using liquid chromatography-mass spectrometry, gas chromatography-mass spectrometry (GC-MS), capillary electrophoresis-mass spectrometry, and matrix assisted laser desorption ionization-mass spectrometry. Then, the findings of studies about GC-MS-based metabolome analysis of gastroenterological diseases are summarized, and our research results are also introduced. Finally, we discuss the realization of disease diagnosis by metabolome analysis. The development of metabolome analysis using mass spectrometry will aid the discovery of novel biomarkers, hopefully leading to the early detection of various diseases.
Porto, Suely K S S; Nogueira, Thiago; Blanes, Lucas; Doble, Philip; Sabino, Bruno D; do Lago, Claudimir L; Angnes, Lúcio
2014-11-01
A method for the identification of 3,4-methylenedioxymethamphetamine (MDMA) and meta-chlorophenylpiperazine (mCPP) was developed employing capillary electrophoresis (CE) with capacitively coupled contactless conductivity detection (C(4) D). Sample extraction, separation, and detection of "Ecstasy" tablets were performed in <10 min without sample derivatization. The separation electrolyte was 20 mm TAPS/Lithium, pH 8.7. Average minimal detectable amounts for MDMA and mCPP were 0.04 mg/tablet, several orders of magnitude lower than the minimum amount encountered in a tablet. Seven different Ecstasy tablets seized in Rio de Janeiro, Brazil, were analyzed by CE-C(4) D and compared against routine gas chromatography-mass spectrometry (GC-MS). The CE method demonstrated sufficient selectivity to discriminate the two target drugs, MDMA and mCPP, from the other drugs present in seizures, namely amphepramone, fenproporex, caffeine, lidocaine, and cocaine. Separation was performed in <90 sec. The advantages of using C(4) D instead of traditional CE-UV methods for in-field analysis are also discussed. © 2014 American Academy of Forensic Sciences.
Radstake, Timothy R D J; Fransen, Jaap; Toonen, Erik J M; Coenen, Marieke J H; Eijsbouts, Agnes E; Donn, Rachelle; van den Hoogen, Frank H J; van Riel, Piet L C M
2007-11-01
Macrophage migration inhibitory factor (MIF) is an inflammatory mediator associated with RA severity. In various diseases, MIF polymorphisms are associated with clinical response glucocorticoid (GC) treatment. It is unclear whether MIF polymorphisms determine GC response in rheumatoid arthritis (RA) and to other RA treatments. Therefore, the question of whether two functional variants in MIF are associated with the response to tumour necrosis factor (TNF)alpha-neutralising and GC treatments in RA was investigated. Data from two cohorts of an RA registry were used. For patients who started with TNFalpha-neutralising (infliximab) or GC treatment, courses with a duration of at least 3 months were included and response to TNFalpha blockers or GC was calculated according to the European League Against Rheumatism response criteria. MIF -173G-->C genotyping was achieved using an assay-on-demand allelic discrimination assay, and alleles of the CATT repeat element were identified using a fluorescently labelled PCR primer and capillary electrophoresis. Logistic-regression modelling was used for the statistical analysis. In total, 192 courses of oral prednisone or methylprednisolone injections in 98 patients with RA and 90 patients with RA who were on TNFalpha-neutralising treatments were documented. In all, 27% of the patients with RA were found to be heterozygous for seven CATT repeats (CATT(7)) and 31% were heterozygous for -173C. Respectively, 4% and 6% of the patients with RA were homozygous for the MIF CATT(7) repeat or the MIF -173C allele. Carrier status and homozygosity for CATT(7 )repeat and the MIF -173C allele were not associated with response to GC (odds ratios (ORs) close to 1) or to TNFalpha-neutralising treatment (ORs close to 2). The MIF-CATT(7) repeat and the MIF-173G-->C functional variant are not strongly associated with a decreased clinical response to TNFalpha-neutralising or GC treatment in RA.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heyman, Heino M.; Zhang, Xing; Tang, Keqi
2016-02-16
Metabolomics is the quantitative analysis of all metabolites in a given sample. Due to the chemical complexity of the metabolome, optimal separations are required for comprehensive identification and quantification of sample constituents. This chapter provides an overview of both conventional and advanced separations methods in practice for reducing the complexity of metabolite extracts delivered to the mass spectrometer detector, and covers gas chromatography (GC), liquid chromatography (LC), capillary electrophoresis (CE), supercritical fluid chromatography (SFC) and ion mobility spectrometry (IMS) separation techniques coupled with mass spectrometry (MS) as both uni-dimensional and as multi-dimensional approaches.
Rossner, Alan; Farant, Jean-Pierre
2004-02-01
Evacuated canisters have been used for many years to collect ambient air samples for gases and vapors. Recently, significant interest has arisen in using evacuated canisters for personal breathing zone sampling as an alternative to sorbent sampling. A novel flow control device was designed and built at McGill University. The flow control device was designed to provide a very low flow rate, <0.5 mL/min, to allow a sample to be collected over an extended period of time. Previous experiments run at McGill have shown agreement between the mathematical and empirical models to predict flow rate. The flow control device combined with an evacuated canister (capillary flow control-canister) was used in a series of experiments to evaluate its performance against charcoal tubes and diffusive badges. Air samples of six volatile organic compounds were simultaneously collected in a chamber using the capillary flow control-canister, charcoal tubes, and diffusive badges. Five different concentrations of the six volatile organic compounds were evaluated. The results from the three sampling devices were compared to each other and to concentration values obtained using an online gas chromatograph (GC). Eighty-four samples of each method were collected for each of the six chemicals. Results indicate that the capillary flow control-canister device compares quite favorably to the online GC and to the charcoal tubes, p > 0.05 for most of the tests. The capillary flow control-canister was found to be more accurate for the compounds evaluated, easier to use, and easier to analyze than charcoal tubes and passive dosimeter badges.
Islam, M D Azharul; Yamakawa, Rei; Do, Nguyen Duc; Numakura, Naoko; Suzuki, Toshiro; Ando, Tetsu
2009-05-01
Conjugated dienyl compounds make one of the main groups of lepidopteran sex pheromones, and GC has been frequently used to determine the configurations of the double bonds. However, the separation of two geometric isomers of a terminal-conjugated diene, such as 7,9-decadien-1-ol secreted by a nettle moth Parasa lepida lepida (Limacodidae), is assumed to be difficult. In order to clarify the chromatographic separation of the terminal dienes, 7,9-decadienyl and 9,11-dodecadienyl compounds (alcohols, acetates, and aldehydes) were analyzed by GC and HPLC. On a capillary GC column, the (E)-isomers flowed out slightly faster than the corresponding (Z)-isomers, but their peaks almost overlapped. On the other hand, HPLC equipped with an ODS column completely separated the two geometric isomers examined and the (Z)-isomers eluted from the column faster than the (E)-isomers without dependence on a functional group. In addition to undergoing direct HPLC analysis without derivatization, the dienyl alcohols were converted into 3,5-dinitrobenzoates and analyzed by LC-ESI-MS operated under the same reversed-phase condition. The two separated geometric isomers were sensitively monitored by negative ions at m/z 211, M, M+1, M+17, and M+31, which were characteristically derived from the benzoates. Based on these results, a pheromone extract of P. l. lepida was examined, and it was confirmed that the female moths exclusively produced the (Z)-isomer of the 7,9-diene. Furthermore, a GC-EAD analysis and a field evaluation with both geometrical isomers indicated that the mating communication of P. l. lepida is predominantly mediated with the (Z)-isomer.
Development of an indirect enzyme linked immunoassay for abscisic acid. [Pisum sativum
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ross, G.S.; Elder, P.A.; McWha, J.A.
1987-09-01
AN INDIRECT METHOD OF ENZYME-LINKED-IMMUNOSORBENT-ASSAY (ELISA) IS REPORTED FOR ABSCISIC ACID (ABA), UTILIZING A THYROGLOBULIN-ABA CONJUGATE FOR COATING WELLS. THE ASSAY CAN USE COMMERCIALLY AVAILABLE MONOCLONAL ANTIBODIES, IS SENSITIVE TO AS LITTLE AS 20 PICOGRAMS ABA PER WELL, AND IS MUCH MORE CONSERVATIVE OF ANTIBODY THAN DIRECT METHODS. THE MOST DILUTE ABA STANDARDS DID NOT RETAIN THEIR ANTIGENICITY DURING STORAGE, SO ABA STANDARD SETS WERE DILUTED IMMEDIATELY PRIOR TO USE. THE INDIRECT ELISA WAS USED SUCCESSFULLY TO ESTIMATE ABA CONCENTRATIONS IN DEVELOPING COTYLEDONS OF PISUM SATIVUM L., AFTER ONLY LITTLE PRELIMINARY PURIFICATION. IT WAS VALIDATED FOR THIS TISSUE THROUGH THEmore » USE OF GAS CHROMATOGRAPHY-ELECTRON CAPTURE DETECTION (GC-EC), AND CAPILLARY GC-SELECTED ION MONITORING (GC-MS-SIM) USING LABELLED ABA AS AN INTERNAL STANDARD. FULL SPECTRUM GC-MASS SPECTROMETRY WAS ALSO USED TO VERIFY THAT ABA WAS PRESENT IN A SAMPLE ASSAYED QUANTITATIVELY BY BOTH ELISA AND GC-MS-SIM.« less
Microplasmas for chemical analysis: analytical tools or research toys?
NASA Astrophysics Data System (ADS)
Karanassios, Vassili
2004-07-01
An overview of the activities of the research groups that have been involved in fabrication, development and characterization of microplasmas for chemical analysis over the last few years is presented. Microplasmas covered include: miniature inductively coupled plasmas (ICPs); capacitively coupled plasmas (CCPs); microwave-induced plasmas (MIPs); a dielectric barrier discharge (DBD); microhollow cathode discharge (MCHD) or microstructure electrode (MSE) discharges, other microglow discharges (such as those formed between "liquid" electrodes); microplasmas formed in micrometer-diameter capillary tubes for gas chromatography (GC) or high-performance liquid chromatography (HPLC) applications, and a stabilized capacitive plasma (SCP) for GC applications. Sample introduction into microplasmas, in particular, into a microplasma device (MPD), battery operation of a MPD and of a mini- in-torch vaporization (ITV) microsample introduction system for MPDs, and questions of microplasma portability for use on site (e.g., in the field) are also briefly addressed using examples of current research. To emphasize the significance of sample introduction into microplasmas, some previously unpublished results from the author's laboratory have also been included. And an overall assessment of the state-of-the-art of analytical microplasma research is provided.
Characterization of volatile aroma compounds from red and black rice bran.
Sukhonthara, Sukhontha; Theerakulkait, Chockchai; Miyazawa, Mitsuo
2009-01-01
The volatile oils from red and black rice bran were obtained by hydrodistillation using diethyl ester and the components of that oil were analyzed by capillary GC-MS. The volatile components of essential oil from red and black rice bran were analyzed by GC and GC-MS. One hundred twenty-nine (129) of volatile compounds were identified in red and black rice bran. Myristic acid, nonanal, (E)-beta-ocimene and 6, 10, 14-trimethyl-2-pentadecanone were main compounds in red rice bran, whereas myristic acid, nonanal, caproic acid, pentadecanal and pelargonic acid were main compounds in black rice bran. Guaiacol, presented at 0.81 mg/100 g in black rice bran, is responsible for the characteristic component in black rice.
Schwartz, Ted R.; Tillitt, Donald E.; Feltz, Kevin P.; Peterman, Paul H.
1993-01-01
High resolution capillary gas chromatography (GC) is the best known technique for the separation of complex mixtures; however, no single GC column has yet separated all 209 congeners of polychlorinated biphenyls (PCBs). A number of coeluting PCB congener pairs exist, and even under favorable separation conditions such as with multidimensional GC, assignment of peak identities to known PCB structures is tedious, subject to errors from other contaminants, and requires enrichment to achieve the necessary detection limits for the most toxic PCB congeners. Routine analysis of PCBs is also complicated by coelution with other halogenated hydrocarbons such as naphthalenes, terphenyls, dibenzofurans, and pesticides. Therefore, techniques for class separations of PCBs prior to gas chromatography must be developed. These techniques should separate PCB congeners along lines that have environmental or toxicological significance. The unique ability of activated carbon to separate halogenated aromatics on the basis of molecular planarity and degree of halogenation has been demonstrated. We present a method that uses dispersed carbon on glass fibers and commercially available instrumentation to fractionate and determine mono- and non-o,o′-chlorine substituted PCB congeners in Aroclors and environmental samples.
determine the concentrations of various toxaphene congeners and technical toxaphene (with other toxaphene congeners and compounds from Method 8081) in extracts from solidliquid matrices, using fused-silica, open-tubular capillary columns with (NICI/MS).
Capillary microextraction: A new method for sampling methamphetamine vapour.
Nair, M V; Miskelly, G M
2016-11-01
Clandestine laboratories pose a serious health risk to first responders, investigators, decontamination companies, and the public who may be inadvertently exposed to methamphetamine and other chemicals used in its manufacture. Therefore there is an urgent need for reliable methods to detect and measure methamphetamine at such sites. The most common method for determining methamphetamine contamination at former clandestine laboratory sites is selected surface wipe sampling, followed by analysis with gas chromatography-mass spectrometry (GC-MS). We are investigating the use of sampling for methamphetamine vapour to complement such wipe sampling. In this study, we report the use of capillary microextraction (CME) devices for sampling airborne methamphetamine, and compare their sampling efficiency with a previously reported dynamic SPME method. The CME devices consisted of PDMS-coated glass filter strips inside a glass tube. The devices were used to dynamically sample methamphetamine vapour in the range of 0.42-4.2μgm -3 , generated by a custom-built vapour dosing system, for 1-15min, and methamphetamine was analysed using a GC-MS fitted with a ChromatoProbe thermal desorption unit. The devices showed good reproducibility (RSD<15%), and a curvilinear pre-equilibrium relationship between sampling times and peak area, which can be utilised for calibration. Under identical sampling conditions, the CME devices were approximately 30 times more sensitive than the dynamic SPME method. The CME devices could be stored for up to 3days after sampling prior to analysis. Consecutive sampling of methamphetamine and its isotopic substitute, d-9 methamphetamine showed no competitive displacement. This suggests that CME devices, pre-loaded with an internal standard, could be a feasible method for sampling airborne methamphetamine at former clandestine laboratories. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Acylation of Chiral Alcohols: A Simple Procedure for Chiral GC Analysis.
Oromí-Farrús, Mireia; Torres, Mercè; Canela, Ramon
2012-01-01
The use of iodine as a catalyst and either acetic or trifluoroacetic acid as a derivatizing reagent for determining the enantiomeric composition of acyclic and cyclic aliphatic chiral alcohols was investigated. Optimal conditions were selected according to the molar ratio of alcohol to acid, the reaction time, and the reaction temperature. Afterwards, chiral stability of chiral carbons was studied. Although no isomerization was observed when acetic acid was used, partial isomerization was detected with the trifluoroacetic acid. A series of chiral alcohols of a widely varying structural type were then derivatized with acetic acid using the optimal conditions. The resolution of the enantiomeric esters and the free chiral alcohols was measured using a capillary gas chromatograph equipped with a CP Chirasil-DEX CB column. The best resolutions were obtained with 2-pentyl acetates (α = 3.00) and 2-hexyl acetates (α = 1.95). This method provides a very simple and efficient experimental workup procedure for analyzing chiral alcohols by chiral-phase GC.
NASA Astrophysics Data System (ADS)
McGuire, N. D.; Ewen, R. J.; de Lacy Costello, B.; Garner, C. E.; Probert, C. S. J.; Vaughan, K.; Ratcliffe, N. M.
2014-06-01
Rapid volatile profiling of stool sample headspace was achieved using a combination of short multi-capillary chromatography column (SMCC), highly sensitive heated metal oxide semiconductor sensor and artificial neural network software. For direct analysis of biological samples this prototype offers alternatives to conventional gas chromatography (GC) detectors and electronic nose technology. The performance was compared to an identical instrument incorporating a long single capillary column (LSCC). The ability of the prototypes to separate complex mixtures was assessed using gas standards and homogenized in house ‘standard’ stool samples, with both capable of detecting more than 24 peaks per sample. The elution time was considerably faster with the SMCC resulting in a run time of 10 min compared to 30 min for the LSCC. The diagnostic potential of the prototypes was assessed using 50 C. difficile positive and 50 negative samples. The prototypes demonstrated similar capability of discriminating between positive and negative samples with sensitivity and specificity of 85% and 80% respectively. C. difficile is an important cause of hospital acquired diarrhoea, with significant morbidity and mortality around the world. A device capable of rapidly diagnosing the disease at the point of care would reduce cases, deaths and financial burden.
McGuire, N D; Ewen, R J; de Lacy Costello, B; Garner, C E; Probert, C S J; Vaughan, K.; Ratcliffe, N M
2016-01-01
Rapid volatile profiling of stool sample headspace was achieved using a combination of short multi-capillary chromatography column (SMCC), highly sensitive heated metal oxide semiconductor (MOS) sensor and artificial neural network (ANN) software. For direct analysis of biological samples this prototype offers alternatives to conventional GC detectors and electronic nose technology. The performance was compared to an identical instrument incorporating a long single capillary column (LSCC). The ability of the prototypes to separate complex mixtures was assessed using gas standards and homogenised in house ‘standard’ stool samples, with both capable of detecting more than 24 peaks per sample. The elution time was considerably faster with the SMCC resulting in a run time of 10 minutes compared to 30 minutes for the LSCC. The diagnostic potential of the prototypes was assessed using 50 C. difficile positive and 50 negative samples. The prototypes demonstrated similar capability of discriminating between positive and negative samples with sensitivity and specificity of 85% and 80% respectively. C. difficile is an important cause of hospital acquired diarrhoea, with significant morbidity and mortality around the world. A device capable of rapidly diagnosing the disease at the point of care would reduce cases, deaths and financial burden. PMID:27212803
Lowe, Ross H.; Karschner, Erin L.; Schwilke, Eugene W.; Barnes, Allan J.; Huestis, Marilyn A.
2009-01-01
A two-dimensional (2D) gas chromatography/electron impact-mass spectrometry (GC/EI-MS) method for simultaneous quantification of Δ9-tetrahydrocannabinol (THC), 11-hydroxy-Δ9-tetrahydrocannabinol (11-OH-THC), and 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid (THCCOOH) in human plasma was developed and validated. The method employs 2D capillary GC and cryofocusing for enhanced resolution and sensitivity. THC, 11-OH-THC, and THCCOOH were extracted by precipitation with acetonitrile followed by solid-phase extraction. GC separation of trimethylsilyl derivatives of analytes was accomplished with two capillary columns in series coupled via a pneumatic Deans switch system. Detection and quantification were accomplished with a bench-top single quadrupole mass spectrometer operated in electron impact-selected ion monitoring mode. Limits of quantification (LOQ) were 0.125, 0.25 and 0.125 ng/mL for THC, 11-OH-THC, and THCCOOH, respectively. Accuracy ranged from 86.0 to 113.0% for all analytes. Intra- and inter-assay precision, as percent relative standard deviation, was less than 14.1% for THC, 11-OH-THC, and THCCOOH. The method was successfully applied to quantification of THC and its 11-OH-THC and THCCOOH metabolites in plasma specimens following controlled administration of THC. PMID:17640656
Wilson, Ryan B; Siegler, W Christopher; Hoggard, Jamin C; Fitz, Brian D; Nadeau, Jeremy S; Synovec, Robert E
2011-05-27
By taking into consideration band broadening theory and using those results to select experimental conditions, and also by reducing the injection pulse width, peak capacity production (i.e., peak capacity per separation time) is substantially improved for one dimensional (1D-GC) and comprehensive two dimensional (GC×GC) gas chromatography. A theoretical framework for determining the optimal linear gas velocity (the linear gas velocity producing the minimum H), from experimental parameters provides an in-depth understanding of the potential for GC separations in the absence of extra-column band broadening. The extra-column band broadening is referred to herein as off-column band broadening since it is additional band broadening not due to the on-column separation processes. The theory provides the basis to experimentally evaluate and improve temperature programmed 1D-GC separations, but in order to do so with a commercial 1D-GC instrument platform, off-column band broadening from injection and detection needed to be significantly reduced. Specifically for injection, a resistively heated transfer line is coupled to a high-speed diaphragm valve to provide a suitable injection pulse width (referred to herein as modified injection). Additionally, flame ionization detection (FID) was modified to provide a data collection rate of 5kHz. The use of long, relatively narrow open tubular capillary columns and a 40°C/min programming rate were explored for 1D-GC, specifically a 40m, 180μm i.d. capillary column operated at or above the optimal average linear gas velocity. Injection using standard auto-injection with a 1:400 split resulted in an average peak width of ∼1.5s, hence a peak capacity production of 40peaks/min. In contrast, use of modified injection produced ∼500ms peak widths for 1D-GC, i.e., a peak capacity production of 120peaks/min (a 3-fold improvement over standard auto-injection). Implementation of modified injection resulted in retention time, peak width, peak height, and peak area average RSD%'s of 0.006, 0.8, 3.4, and 4.0%, respectively. Modified injection onto the first column of a GC×GC coupled with another high-speed valve injection onto the second column produced an instrument with high peak capacity production (500-800peaks/min), ∼5-fold to 8-fold higher than typically reported for GC×GC. Copyright © 2011 Elsevier B.V. All rights reserved.
Burger, Jessica L; Lovestead, Tara M; Bruno, Thomas J
2016-03-17
As the sources of natural gas become more diverse, the trace constituents of the C 6 + fraction are of increasing interest. Analysis of fuel gas (including natural gas) for compounds with more than 6 carbon atoms (the C 6 + fraction) has historically been complex and expensive. Hence, this is a procedure that is used most often in troubleshooting rather than for day-to-day operations. The C 6 + fraction affects gas quality issues and safety considerations such as anomalies associated with odorization. Recent advances in dynamic headspace vapor collection can be applied to this analysis and provide a faster, less complex alternative for compositional determination of the C 6 + fraction of natural gas. Porous layer open tubular capillaries maintained at low temperatures (PLOT-cryo) form the basis of a dynamic headspace sampling method that was developed at NIST initially for explosives in 2009. This method has been recently advanced by the combining of multiple PLOT capillary traps into one "bundle," or wafer, resulting in a device that allows the rapid trapping of relatively large amounts of analyte. In this study, natural gas analytes were collected by flowing natural gas from the laboratory (gas out of the wall) or a prepared surrogate gas flowing through a chilled wafer. The analytes were then removed from the PLOT-cryo wafer by thermal desorption and subsequent flushing of the wafer with helium. Gas chromatography (GC) with mass spectrometry (MS) was then used to identify the analytes.
Chen, Kuan-Fu; Wu, Hui-Hsin; Lin, Chien-Hung; Lin, Cheng-Huang
2013-08-30
The use of an accelerometer for detecting inorganic gases in gas chromatography (GC) is described. A milli-whistle was connected to the outlet of the GC capillary and was used instead of a classical GC detector. When the GC carrier gases and the sample gases pass through the milli-whistle, a sound is produced, leading to vibrational changes, which can be recorded using an accelerometer. Inorganic gases, including SO2, N2 and CO2, which are released from traditional Chinese firework-rockets at relatively high levels as the result of burning the propellant and explosive material inside could be rapidly determined using the GC/whistle-accelerometer system. The method described herein is safe, the instrumentation is compact and has potential to be modified so as to be portable for use in the field. It also can be used in conjunction with FID (flame ionization detector) or TCD (thermal conductivity detector), in which either no response for FID (CO2, N2, NO2, SO2, etc.) or helium gas is needed for TCD, respectively. Copyright © 2013 Elsevier B.V. All rights reserved.
Devos, Christophe; Ochiai, Nobuo; Sasamoto, Kikuo; Sandra, Pat; David, Frank
2012-09-14
Suspected fragrance allergens were determined in cosmetic products using a combination of full evaporation-dynamic headspace (FEDHS) with selectable one-dimensional/two-dimensional GC-MS. The full evaporation dynamic headspace approach allows the non-discriminating extraction and injection of both apolar and polar fragrance compounds, without contamination of the analytical system by high molecular weight non-volatile matrix compounds. The method can be applied to all classes of cosmetic samples, including water containing matrices such as shower gels or body creams. In combination with selectable (1)D/(2)D GC-MS, consisting of a dedicated heart-cutting GC-MS configuration using capillary flow technology (CFT) and low thermal mass GC (LTM-GC), a highly flexible and easy-to-use analytical solution is offered. Depending on the complexity of the perfume fraction, analyses can be performed in one-dimensional GC-MS mode or in heart-cutting two-dimensional GC-MS mode, without the need of hardware reconfiguration. The two-dimensional mode with independent temperature control of the first and second dimension column is especially useful to confirm the presence of detected allergen compounds when mass spectral deconvolution is not possible. Copyright © 2012 Elsevier B.V. All rights reserved.
He, Yi-San; Chen, Kuan-Fu; Lin, Chien-Hung; Lin, Min-Tsung; Chen, Chien-Chung; Lin, Cheng-Huang
2013-03-19
The use of an accelerometer as a gas detector in gas chromatography (GC) is described for the first time. A milli-whistle was connected to the outlet of the GC capillary. When the eluted and GC carrier gases pass through the capillary and milli-whistle, a sound is produced. After a fast Fourier transform (FFT), the sound wave generated from the milli-whistle is picked up by a microphone and the resulting vibration of the milli-whistle body can be recorded by an accelerometer. The release of hydrogen gas, as the result of thermal energy, from ammonia borane (NH3BH3), which has been suggested as a storage medium for hydrogen, was selected as the model sample. The findings show that the frequencies generated, either by sound or by the vibration from the whistle body, were identical. The concentration levels of the released hydrogen gas can be determined online, based on the frequency changes. Ammonia borane was placed in a brass reservoir, heated continually, and the released hydrogen gas was directly injected into the GC inlet at 0.5 min intervals, using a home-built electromagnetic pulse injector. The concentration of hydrogen for each injection can be calculated immediately. When the ammonia borane was encapsulated within a polycarbonate (PC) microtube array membrane, the temperature required for the release of hydrogen can be decreased, which would make such a material more convenient for use. The findings indicate that 1.0 mg of ammonia borane can produce hydrogen in the range of 1.0-1.25 mL, in the temperature range of 85-115 °C.
NASA Astrophysics Data System (ADS)
Shiryaeva, V. E.; Popova, T. P.; Korolev, A. A.; Kanat'eva, A. Yu.; Kurganov, A. A.
2017-08-01
New stationary phases for capillary columns in GC are synthesized and studied. The phases are prepared by depositing oligo(ethylene glycol)diacrylates on the column walls and subsequent polymerization (crosslinking) in the presence of peroxide initiators. It is shown that stationary phases based on monomers with molecular weights of 10 kDa or higher exhibit separation properties similar to those of conventional stationary phases based on polyethylene glycol (PEG); however, their thermal stability is higher because they have a higher degree of crosslinking and a more ordered structure of the crosslinked polymers than the respective parameters of phases based on native PEG.
Huang, Yu-San; Liu, Ju-Tsung; Lin, Li-Chang; Lin, Cheng-Huang
2003-03-01
The R-(-)- and S-(+)-isomers of 3,4-methylenedioxymethamphetamine (MDMA) and its metabolite 3,4-methylenedioxyamphetamine (MDA) were prepared, identified by gas chromatography/mass spectrometry (GC/MS) and then used as standards in a series of capillary electrophoresis (CE) experiments. Using these R-(-)- and S-(+)-isomers, the distribution of (RS)-MDA and (RS)-MDMA stereoisomers in clandestine tablets and suspect urine samples were identified. Several electrophoretic parameters, such as the concentration of beta-cyclodextrin used in the electrophoretic separation and the amount of organic solvents required for the separation, were optimized.
SPE-GC/FTD determination of N-methyl-2-pyrrolidone and its metabolites in urine.
Kubota, Ryuichi; Endo, Yoko; Takeuchi, Akito; Inoue, Yoshinori; Ogata, Hiroko; Ogawa, Masanori; Nakagawa, Tomoo; Onda, Nobuhiko; Endo, Ginji
2007-07-01
An analytical method using a combination of solid-phase extraction (SPE) and gas chromatography with a flame thermionic detector (GC/FTD) was developed for determination of N-methyl-2-pyrrolidone (NMP), N-methylsuccinimide (MSI), and 2-hydroxy-N-methylsuccinimide (2-HMSI) in human urine. The SPE cartridge of poly(divinylbenzene/hydroxymethacrylate) used was directly loaded with urine sample, followed by elution with methyl isobutyl ketone (MIBK) and subsequent centrifugation, and the supernatant was injected into the capillary GC using a DB1701. This method allowed efficient separation of NMP, MSI, and 2-HMSI, which were nearly free of interference by other GC peaks arising from urine. Recoveries of NMP, MSI, and 2-HMSI from the SPE cartridge were about 98, 101, and 67%, respectively, with limits of detection of 0.04, 0.02, and 0.06 mg/L, respectively, which met the regulatory requirements. The present method was used for assay in biological monitoring of workers exposed to NMP in their occupational environment.
Wang, Mei; Zhao, Jianping; Avula, Bharathi; Wang, Yan-Hong; Avonto, Cristina; Chittiboyina, Amar G; Wylie, Philip L; Parcher, Jon F; Khan, Ikhlas A
2014-12-17
A high-resolution gas chromatography/mass spectrometry (GC/MS) with selected ion monitor method focusing on the characterization and quantitative analysis of ginkgolic acids (GAs) in Ginkgo biloba L. plant materials, extracts, and commercial products was developed and validated. The method involved sample extraction with (1:1) methanol and 10% formic acid, liquid-liquid extraction with n-hexane, and derivatization with trimethylsulfonium hydroxide (TMSH). Separation of two saturated (C13:0 and C15:0) and six unsaturated ginkgolic acid methyl esters with different positional double bonds (C15:1 Δ8 and Δ10, C17:1 Δ8, Δ10, and Δ12, and C17:2) was achieved on a very polar (88% cyanopropyl) aryl-polysiloxane HP-88 capillary GC column. The double bond positions in the GAs were determined by ozonolysis. The developed GC/MS method was validated according to ICH guidelines, and the quantitation results were verified by comparison with a standard high-performance liquid chromatography method. Nineteen G. biloba authenticated and commercial plant samples and 21 dietary supplements purported to contain G. biloba leaf extracts were analyzed. Finally, the presence of the marker compounds, terpene trilactones and flavonol glycosides for Ginkgo biloba in the dietary supplements was determined by UHPLC/MS and used to confirm the presence of G. biloba leaf extracts in all of the botanical dietary supplements.
Wang, Si-Cen; Chen, Qin-Hua; Wei, Yao-Yuan; Li, Han-Wen; He, Lang-Chong
2007-05-01
To analyze the constituents in supercritical fluid CO2 extraction (SFE-CO2) of Radix caulophylli, the Radix caulophylli was extracted with SFE-CO2, and analyzed by gas chromatography-mass spectrometry (GC-MS). The GC-MS analysis with a DB-5MS capillary column (30 mm x 0.32 mm ID, 0.25 microm film thickness) was used. The inlet temperature was maintained at 280 degrees C. The column oven was held at 80 degrees C for 2 min, then programmed from 80 to 280 degrees C at 5 degrees C x min(-1) and, finally, held for 4 min. Helium at a constant flow rate of 2.0 mL x min(-1) was used as the carrier gas. The mass spectrometry conditions were as follows: ionization energy, 70 eV; ion source temperature, 200 degrees C. The mass selective detector was operated in the TIC mode (m/z was from 40 - 500). For the first time 49 peaks were separated and identified, the compounds were quantitatively determined by normalization method, and the identified compounds represent 97.44% of total GC peak areas. Viz, n-hexadecanoic acid (31.4%), (E, E) -9, 12-octadecadienoic acid (26.54%), (Z)-7-tetradecenal (9.4%), hexadecenoic acid (3.23%), 10-undecenal (3.22%), octadecanoic acid (2.25%), and caulophylline (1.76%) etc. The results will provide important foundation for understanding the constituents and further exploitation of Radix caulophylli.
Capillary gas chromatography with GC/PFPD was used in the development of analytical methodology for determining both non-pesticidal and pesticidal organotin compounds in drinking water and other aqueous matrices. The method involves aqueous ethylation of organotin analytes with ...
Bieri, Stefan; Ilias, Yara; Bicchi, Carlo; Veuthey, Jean-Luc; Christen, Philippe
2006-04-21
An effective combination of focused microwave-assisted extraction (FMAE) with solid-phase microextraction (SPME) prior to gas chromatography (GC) is described for the selective extraction and quantitative analysis of cocaine from coca leaves (Erythroxylum coca). This approach required switching from an organic extraction solvent to an aqueous medium more compatible with SPME liquid sampling. SPME was performed in the direct immersion mode with a universal 100 microm polydimethylsiloxane (PDMS) coated fibre. Parameters influencing this extraction step, such as solution pH, sampling time and temperature are discussed. Furthermore, the overall extraction process takes into account the stability of cocaine in alkaline aqueous solutions at different temperatures. Cocaine degradation rate was determined by capillary electrophoresis using the short end injection procedure. In the selected extraction conditions, less than 5% of cocaine was degraded after 60 min. From a qualitative point of view, a significant gain in selectivity was obtained with the incorporation of SPME in the extraction procedure. As a consequence of SPME clean-up, shorter columns could be used and analysis time was reduced to 6 min compared to 35 min with conventional GC. Quantitative results led to a cocaine content of 0.70 +/- 0.04% in dry leaves (RSD <5%) which agreed with previous investigations.
Comparison of HPLC and CE for the analysis of dichlorprop in a case of intoxication.
West, A; Frost, M; Köhler, H
1997-01-01
A 49-year-old white male was found lying unconscious at home. He had vomited, his mouth was filled with a white foam and a pungent odour filled the room. After emergency treatment blood, urine and stomach contents were screened for drugs after acid and alkaline extraction with subsequent derivatisation and GC-MS analysis. Large quantites of 2,4-dichlorophenoxypropionic acid (dichlorprop, 2,4-DP) were found in all acid extracts. The man died 3 h later in hospital. Body fluids and tissues obtained at autopsy were analysed for 2,4-DP by high-performance liquid chromatography and capillary electrophoresis. The concentrations of 2,4-DP in cardiac blood, stomach contents, bile, liver, spleen, kidney and brain found by both methods were very similar.
Quantitative on-line analysis of sulfur compounds in complex hydrocarbon matrices.
Djokic, Marko R; Ristic, Nenad D; Olahova, Natalia; Marin, Guy B; Van Geem, Kevin M
2017-08-04
An improved method for on-line measurement of sulfur containing compounds in complex matrices is presented. The on-line system consists of a specifically designed sampling system connected to a comprehensive two-dimensional gas chromatograph (GC×GC) equipped with two capillary columns (Rtx ® -1 PONA×SGE BPX50), a flame ionization detector (FID) and a sulfur chemiluminescence detector (SCD). The result is an unprecedented sensitivity down to ppm level (1 ppm-w) for various sulfur containing compounds in very complex hydrocarbon matrices. In addition to the GC×GC-SCD, the low molecular weight sulfur containing compounds such as hydrogen sulfide (H 2 S) and carbonyl sulfide (COS) can be analyzed using a thermal conductivity detector of a so-called refinery gas analyzer (RGA). The methodology was extensively tested on a continuous flow pilot plant for steam cracking, in which quantification of sulfur containing compounds in the reactor effluent was carried out using 3-chlorothiophene as internal standard. The GC×GC-FID/-SCD settings were optimized for ppm analysis of sulfur compounds in olefin-rich (ethylene- and propylene-rich) hydrocarbon matrices produced by steam cracking of petroleum feedstocks. Besides that is primarily used for analysis of the hydrocarbon matrix, FID of the GC×GC-FID/-SCD set-up serves to double check the amount of added sulfur internal standard which is crucial for a proper quantification of sulfur compounds. When vacuum gas oil containing 780 ppm-w of elemental sulfur in the form of benzothiophenes and dibenzothiophenes is subjected to steam cracking, the sulfur balance was closed, with 75% of the sulfur contained in the feed is converted to hydrogen sulfide, 13% to alkyl homologues of thiophene while the remaining 12% is present in the form of alkyl homologues of benzothiophenes. The methodology can be applied for many other conversion processes which use sulfur containing feeds such as hydrocracking, catalytic cracking, kerogen evolution, bio-waste pyrolysis, supercritical water treatment, etc. Copyright © 2017 Elsevier B.V. All rights reserved.
Burger, Jessica L.; Lovestead, Tara M.; Bruno, Thomas J.
2017-01-01
As the sources of natural gas become more diverse, the trace constituents of the C6+ fraction are of increasing interest. Analysis of fuel gas (including natural gas) for compounds with more than 6 carbon atoms (the C6+ fraction) has historically been complex and expensive. Hence, this is a procedure that is used most often in troubleshooting rather than for day-to-day operations. The C6+ fraction affects gas quality issues and safety considerations such as anomalies associated with odorization. Recent advances in dynamic headspace vapor collection can be applied to this analysis and provide a faster, less complex alternative for compositional determination of the C6+ fraction of natural gas. Porous layer open tubular capillaries maintained at low temperatures (PLOT-cryo) form the basis of a dynamic headspace sampling method that was developed at NIST initially for explosives in 2009. This method has been recently advanced by the combining of multiple PLOT capillary traps into one “bundle,” or wafer, resulting in a device that allows the rapid trapping of relatively large amounts of analyte. In this study, natural gas analytes were collected by flowing natural gas from the laboratory (gas out of the wall) or a prepared surrogate gas flowing through a chilled wafer. The analytes were then removed from the PLOT-cryo wafer by thermal desorption and subsequent flushing of the wafer with helium. Gas chromatography (GC) with mass spectrometry (MS) was then used to identify the analytes. PMID:29332993
Freissinet, C; Buch, A; Szopa, C; Sternberg, R
2013-09-06
The performances of several commercial chiral capillary columns have been evaluated with the aim of determining the one most suitable for enantiomeric separation in a gas chromatograph onboard a space probe. We compared the GC-MS response of three capillary columns coated with different chiral stationary phases (CSP) using volatile chiral organic molecules which are potential markers of a prebiotic organic chemistry. The three different chiral capillary columns are Chirasil-Val, with an amino acid derivative CSP, ChiralDex-β-PM, with a CSP composed of dissolved permethylated β-cyclodextrins in polysiloxane, and Chirasil-Dex, with a CSP made of modified cyclodextrins chemically bonded to the polysiloxane backbone. Both kinetics and thermodynamics studies have been carried out to evaluate the chiral recognition potential in these different types of columns. The thermodynamic parameters also allow a better understanding of the driving forces affecting the retention and separation of the enantiomers. The Chirasil-Dex-CSP displays the best characteristics for an optimal resolution of the chiral compounds, without preliminary derivatization. This CSP had been chosen to be the only chiral column in the Sample Analysis at Mars (SAM) experiment onboard the current Mars Science Laboratory (MSL) mission, and is also part of the Mars Organic Molecules Analyzer (MOMA) gas chromatograph onboard the next Martian mission ExoMars. The use of this column could also be extended to all space missions aimed at studying chirality in space. Copyright © 2013 Elsevier B.V. All rights reserved.
Development and Calibration of an Oil Spill Behavior Model.
1982-09-01
7675A purge-and-trap sampler. The GC column was a wide bore 50 meter long glass capillary column coated with SE-30 (WCOT from Alltech Associates, Inc...commonly used CGS unit of 1 dyne/cm is 10- 9 N/m or 1 milli-Newtons/meter (mN/m). An advantage of the technique is that there is no solid surface in
Method for detection of extremely low concentration
Andresen, Brian D.; Miller, Fred S.
2002-01-01
An ultratrace detector system for hand-held gas chromatography having high sensitivity, for example, to emissions generated during production of weapons, biological compounds, drugs, etc. The detector system is insensitive to water, air, helium, argon, oxygen, and CO.sub.2. The detector system is basically composed of a hand-held capillary gas chromatography (GC), an insulated heated redox-chamber, a detection chamber, and a vapor trap. For example, the detector system may use gas phase redox reactions and spectral absorption of mercury vapor. The gas chromatograph initially separates compounds that percolate through a bed of heated mercuric oxide (HgO) in a silica--or other metal--aerogel material which acts as an insulator. Compounds easily oxidized by HgO liberate atomic mercury that subsequently pass through a detection chamber which includes a detector cell, such as quartz, that is illuminated with a 254 nm ultra-violet (UV) mercury discharge lamp which generates the exact mercury absorption bands that are used to detect the liberated mercury atoms. Atomic mercury strongly absorbs 254 nm energy is therefore a specific signal for reducing compounds eluting from the capillary GC, whereafter the atomic mercury is trapped for example, in a silicon-aerogel trap.
Ultratrace detector for hand-held gas chromatography
Andresen, Brian D.; Miller, Fred S.
1999-01-01
An ultratrace detector system for hand-held gas chromatography having high sensitivity, for example, to emissions generated during production of weapons, biological compounds, drugs, etc. The detector system is insensitive to water, air, helium, argon, oxygen, and C0.sub.2. The detector system is basically composed of a hand-held capillary gas chromatography (GC), an insulated heated redox-chamber, a detection chamber, and a vapor trap. For example, the detector system may use gas phase redox reactions and spectral absorption of mercury vapor. The gas chromatograph initially separates compounds that percolate through a bed of heated mercuric oxide (HgO) in a silica--or other metal--aerogel material which acts as an insulator. Compounds easily oxidized by HgO liberate atomic mercury that subsequently pass through a detection chamber which includes a detector cell, such as quartz, that is illuminated with a 254 nm ultra-violet (UV) mercury discharge lamp which generates the exact mercury absorption bands that are used to detect the liberated mercury atoms. Atomic mercury strongly absorbs 254 nm energy is therefore a specific signal for reducing compounds eluting from the capillary GC, whereafter the atomic mercury is trapped for example, in a silicon-aerogel trap.
Yang, Yinhui; Chang, Zhengfeng; Yang, Xiaohong; Qi, Meiling; Wang, Jinliang
2018-08-03
Herein we report a propeller-like hexaphenylbenzene-based hydrocarbon material (denoted as BT) as the stationary phase for capillary gas chromatography (GC). The statically-coated BT capillary column showed a high column efficiency of 4340 plates m -1 and weak polarity. Owing to its unique conformation, π-electron toroidal delocalization and intrinsic microporosity, the BT stationary phase exhibited interesting selectivity for aromatic compounds over alkanes. Compared with the graphene (G) column, the BT column showed much prolonged retention and high selectivity for aromatic isomers, especially methylnaphthalenes, dimethylnaphthalenes and phenanthrene/anthracene, mainly because of its propeller-like conformation with rich intercalation effects. Moreover, it exhibited good column repeatability (intra-day, inter-day) and reproducibility (between-column) with RSD values on the retention times less than 0.08% for intra-day, 0.32% for inter-day and 3.8% for between-column, respectively. Also, it showed good potential for determination of minor isomer impurities in real samples. To the best of our knowledge, this work presents the first example of employing an neat aromatic hydrocarbon material as the GC stationary phase with high selectivity for analytes of a wide ranging polarity. Copyright © 2018 Elsevier B.V. All rights reserved.
Padalia, Rajendra C; Verma, Ram S; Sundaresan, Velusamy; Chanotiya, Chandan S
2010-08-01
The essential-oil compositions of leaves, flowers, and rhizomes of Alpinia galanga (L.) Willd., Alpinia calcarata Rosc., Alpinia speciosa K. Schum., and Alpinia allughas Rosc. were examined and compared by capillary GC and GC/MS. Monoterpenoids were the major oil constituents identified. 1,8-Cineole, alpha-terpineol, (E)-methyl cinnamate, camphor, terpinen-4-ol, and alpha- and beta-pinenes were the major constituents commonly distributed in leaf and flower essential oils. The presence of endo-fenchyl acetate, exo-fenchyl acetate, and endo-fenchol was the unique feature of rhizome essential oils of A. galanga, A. calcarata, and A. speciosa. On contrary, the rhizome oil of A. allughas was dominated by beta-pinene. Significant qualitative and quantitative variations were observed in essential-oil compositions of different parts of Alpinia species growing in subtemperate and subtropical regions of Northern India. Cluster analysis was performed to find similarities and differences in essential-oil compositions based on representative molecular skeletons. Monoterpenoids, viz., 1,8-cineole, terpinen-4-ol, camphor, pinenes, (E)-methyl cinnamate, and fenchyl derivatives, were used as chemotaxonomic markers.
Burdick, J D; Boni, R L; Fochtman, F W
1997-05-01
A simple solid phase extraction (SPE) technique combined with gas chromatography-mass spectrometry (GC/MS) operated in selected ion monitoring (SIM) mode is described for quantitation of cocaine and cocaethylene in small samples (250 microliters) of rat whole blood. Use of (N-[2H3C])-cocaine and (N-[2H3C])-cocaethylene internal standards resulted in high sensitivity and selectivity for this analytical method. Analysis was performed using a Hewlett-Packard 5890 GC equipped with a 7673A Automatic Liquid Sampler linked to a Hewlett-Packard 5972 Mass Selective Detector. Separation of analytes was accomplished on a cross-linked methyl silicone gum capillary column (Ultra 1: 12m x 0.2mm (i.d.) x 0.33 microns). Linearity was established over a wide range of concentrations (5.0-2000.0 ng ml-1) with good precision. Limits of detection (LOD) were 1.0 and 2.0 ng ml-1 for cocaine and cocaethylene, respectively. This analytical method was designed for use in pharmacokinetic experiments studying the formation of cocaethylene following ethanol pretreatment in rats administered cocaine.
Ren, Yu; Schlager, Hans; Martin, Damien
2014-01-01
A modified method for the quantitative determination of atmospheric perfluoroalkylcycloalkanes (PFCs) using thermal desorption coupled with gas chromatography and detection by negative ion chemical ionization-mass spectrometry was developed. Using an optimized analytical system, a commercially available Al 2 O 3 porous layer open tubular (PLOT) capillary column (30 m × 0.25 mm) deactivated with Na 2 SO 4 was used for separation of PFCs. Improvements in the separation of PFCs, the corresponding identification and the limit of detection of PFCs using this method and column are presented. The method was successfully applied to determine the atmospheric background concentrations of a range of PFCs from a number of samples collected at a rural site in Germany. The results of this study suggest that the method outlined using the Al 2 O 3 -PLOT-S capillary column has good sensitivity and selectivity, and that it can be deployed in a routine laboratory process for the analysis of PFCs in the future research work. In addition, the ability of this column to separate the isomers of one of the lower boiling PFCs (perfluorodimethylcyclobutane) and its ability to resolve perfluoroethylcyclohexane offer the opportunity for single-column analysis for multiple PFCs.
NASA Astrophysics Data System (ADS)
Wu, Sheng; Deev, Andrei
2013-01-01
A field deployable Compound Specific Isotope Analyzer (CSIA) coupled with capillary chromatogrpahy based on Quantum Cascade (QC) lasers and Hollow Waveguide (HWG) with precision and chemical resolution matching mature Mass Spectroscopy has been achieved in our laboratory. The system could realize 0.3 per mil accuracy for 12C/13C for a Gas Chromatography (GC) peak lasting as short as 5 seconds with carbon molar concentration in the GC peak less than 0.5%. Spectroscopic advantages of HWG when working with QC lasers, i.e. single mode transmission, noiseless measurement and small sample volume, are compared with traditional free space and multipass spectroscopy methods.
Ahmed, Trifa M; Lim, Hwanmi; Bergvall, Christoffer; Westerholm, Roger
2013-10-01
A multidimensional, on-line coupled liquid chromatographic/gas chromatographic system was developed for the quantification of polycyclic aromatic hydrocarbons (PAHs). A two-dimensional liquid chromatographic system (2D-liquid chromatography (LC)), with three columns having different selectivities, was connected on-line to a two-dimensional gas chromatographic system (2D-gas chromatography (GC)). Samples were cleaned up by combining normal elution and column back-flush of the LC columns to selectively remove matrix constituents and isolate well-defined, PAH enriched fractions. Using this system, the sequential removal of polar, mono/diaromatic, olefinic and alkane compounds from crude extracts was achieved. The LC/GC coupling was performed using a fused silica transfer line into a programmable temperature vaporizer (PTV) GC injector. Using the PTV in the solvent vent mode, excess solvent was removed and the enriched PAH sample extract was injected into the GC. The 2D-GC setup consisted of two capillary columns with different stationary phase selectivities. Heart-cutting of selected PAH compounds in the first GC column (first dimension) and transfer of these to the second GC column (second dimension) increased the baseline resolutions of closely eluting PAHs. The on-line system was validated using the standard reference materials SRM 1649a (urban dust) and SRM 1975 (diesel particulate extract). The PAH concentrations measured were comparable to the certified values and the fully automated LC/GC system performed the clean-up, separation and detection of PAHs in 16 extracts in less than 24 h. The multidimensional, on-line 2D-LC/2D-GC system eliminated manual handling of the sample extracts and minimised the risk of sample loss and contamination, while increasing accuracy and precision.
Kikura-Hanajiri, R; Hayashi, M; Saisho, K; Goda, Y
2005-10-15
To investigate the trend of non-controlled drugs of abuse, simultaneous analytical methods were developed using GC-MS and LC-ESI-MS for 8 tryptamines/beta-carbolines, 6 phenethylamines of typically non-controlled substances in Japan, and, additionally, five legally controlled tryptamines and phenethylamines originally found in fungi or plants. Moreover, the proposed methods were applied to analyses of these drugs in 99 kinds of products (a total number of 123 products purchased at adult shops or via the Internet over the past 2 years in Japan), which potentially advertised psychotropic/psychoactive effects. The samples were extracted with methanol under ultrasonication. After centrifugation, the extracts were filtered prior to injections. GC-MS analysis was performed using a DB-5MS capillary column. Regarding the LC-ESI-MS analysis; the separation of the target drugs was optimized on an ODS column in acetonitrile/MeOH (7:3)-10 mM ammonium formate buffer (pH 3.5)/acetonitrile (95:5) by a linear gradient program and a quantitative analysis was carried out by the monitoring of each [M+H]+ in the positive ion mode of ESI-MS. As a result of the analyses using GC-MS and LC-ESI-MS, 5-MeO-DIPT (the synthetic substance known by the street name "Foxy") was found in 8 out of the 99 kinds of products. Additionally, AMT (from brown powder), DMT (from dried plant), harmine and harmaline (from dried plant) were also found in some of the 99 products. These analytical methods could be useful for the investigation of the distribution of the non-controlled psychotropic tryptamines/beta-carbolines and phenethylamines in the market.
Johnson, Arielle J.; Hirson, Gregory D.; Ebeler, Susan E.
2012-01-01
This paper describes the design of a new instrumental technique, Gas Chromatography Recomposition-Olfactometry (GC-R), that adapts the reconstitution technique used in flavor chemistry studies by extracting volatiles from a sample by headspace solid-phase microextraction (SPME), separating the extract on a capillary GC column, and recombining individual compounds selectively as they elute off of the column into a mixture for sensory analysis (Figure 1). Using the chromatogram of a mixture as a map, the GC-R instrument allows the operator to “cut apart" and recombine the components of the mixture at will, selecting compounds, peaks, or sections based on retention time to include or exclude in a reconstitution for sensory analysis. Selective recombination is accomplished with the installation of a Deans Switch directly in-line with the column, which directs compounds either to waste or to a cryotrap at the operator's discretion. This enables the creation of, for example, aroma reconstitutions incorporating all of the volatiles in a sample, including instrumentally undetectable compounds as well those present at concentrations below sensory thresholds, thus correcting for the “reconstitution discrepancy" sometimes noted in flavor chemistry studies. Using only flowering lavender (Lavandula angustifola ‘Hidcote Blue’) as a source for volatiles, we used the instrument to build mixtures of subsets of lavender volatiles in-instrument and characterized their aroma qualities with a sensory panel. We showed evidence of additive, masking, and synergistic effects in these mixtures and of “lavender' aroma character as an emergent property of specific mixtures. This was accomplished without the need for chemical standards, reductive aroma models, or calculation of Odor Activity Values, and is broadly applicable to any aroma or flavor. PMID:22912722
Johnson, Arielle J; Hirson, Gregory D; Ebeler, Susan E
2012-01-01
This paper describes the design of a new instrumental technique, Gas Chromatography Recomposition-Olfactometry (GC-R), that adapts the reconstitution technique used in flavor chemistry studies by extracting volatiles from a sample by headspace solid-phase microextraction (SPME), separating the extract on a capillary GC column, and recombining individual compounds selectively as they elute off of the column into a mixture for sensory analysis (Figure 1). Using the chromatogram of a mixture as a map, the GC-R instrument allows the operator to "cut apart" and recombine the components of the mixture at will, selecting compounds, peaks, or sections based on retention time to include or exclude in a reconstitution for sensory analysis. Selective recombination is accomplished with the installation of a Deans Switch directly in-line with the column, which directs compounds either to waste or to a cryotrap at the operator's discretion. This enables the creation of, for example, aroma reconstitutions incorporating all of the volatiles in a sample, including instrumentally undetectable compounds as well those present at concentrations below sensory thresholds, thus correcting for the "reconstitution discrepancy" sometimes noted in flavor chemistry studies. Using only flowering lavender (Lavandula angustifola 'Hidcote Blue') as a source for volatiles, we used the instrument to build mixtures of subsets of lavender volatiles in-instrument and characterized their aroma qualities with a sensory panel. We showed evidence of additive, masking, and synergistic effects in these mixtures and of "lavender' aroma character as an emergent property of specific mixtures. This was accomplished without the need for chemical standards, reductive aroma models, or calculation of Odor Activity Values, and is broadly applicable to any aroma or flavor.
Van Hoeck, Els; Canale, Francesca; Cordero, Chiara; Compernolle, Sien; Bicchi, Carlo; Sandra, Pat
2009-02-01
A multiresidue method for screening endocrine-disrupting chemicals (EDCs) and pharmaceuticals in aqueous samples is presented. Four 10-mL aliquots of water were taken for stir bar sorptive extraction (SBSE) and they were treated in the following way. In sample one, in situ derivatization was performed with acetic acid anhydride to improve the extraction efficiencies and chromatographic analysis of phenolic compounds. For the same reasons, aliquot two was treated with ethyl chloroformate to improve amine and acid extraction and analysis, and aliquot three with tetraethylborate to enhance organotin compound extraction and analysis. Methanol was added to sample four to stop adsorption of apolar solutes on the wall. After SBSE, the four stir bars, together with a plug of glass wool impregnated with bis(trimethylylsilyl)trifluoroacetamide (BSTFA) to derivatize hydroxyl functionalities, were introduced into the same thermal desorption tube, heat-desorbed, and analyzed simultaneously by capillary GC/MS. The figures of merit of the method were evaluated with an EDC model mixture. In scan-mode MS, the limits of detection (LODs) were in the range 1-500 ng/L, while the LODs dropped by a factor of 50-100 when ion monitoring MS was applied to the targets. The performance of the method was illustrated by analysing some real-world water samples.
Devos, Christophe; David, Frank; Sandra, Pat
2012-10-26
According to recent directives of the European Union (EU), limits of quantification (LOQ) for the determination of tributyltin (TBT) in surface waters should be ca. 60 pg/L (ppq). This put very stringent requirements on analytical methodologies; definitely when they have to be applied in a routine environment. Stir bar sorptive extraction (SBSE), followed by thermal desorption (TD) and capillary gas chromatography-triple quadrupole mass spectrometry (GC-MS/MS) can provide accurate and precise data at the 2 ng/L level (ppt). For lower concentrations, matrix and reagent interferences together with contamination may provide too high TBT values. A two-dimensional heart-cut GC method was developed to fractionate TBT from interferences. The GC-GC-MS/MS method shows excellent linearity in the range 50 pg/L-4 ng/L, good repeatability (RSD<20% at 200 pg/L), and a limit of detection of 11 pg/L. The method performance is demonstrated with representative samples i.e. harbor water and waste water samples. Copyright © 2012 Elsevier B.V. All rights reserved.
Fidalgo-Used, Natalia; Montes-Bayón, Maria; Blanco-González, Elisa; Sanz-Medel, Alfredo
2008-05-15
A method for enantioselective determination of bromocyclen enantiomers in fish tissue has been developed. The enantiomers were resolved by capillary gas chromatography (GC) using a commercial chiral column (CP-Chirasil-Dex CB) and a temperature program from 50 degrees C (held for 1 min), raised to 140 degrees C at 40 degrees C min(-1) and then raised at 0.2 degrees C min(-1) to 155 degrees C. This enantioselective gas chromatographic separation was combined with a clean-up/enrichment procedure based on solid-phase microextraction (SPME). Under SPME optimized conditions, precision, linearity range and detection limits of the developed SPME-enantioselective GC procedure were evaluated and compared using two different detection systems: a classical electron-capture detection (ECD) and an element specific detection using inductively coupled plasma mass spectrometry (ICP-MS). The SPME-GC-ECD method exhibited an excellent sensitivity, with detection limits of 0.2 ng L(-1) for each enantiomer of bromocyclen. Although ICP-MS offered poorer detection limits (7 ng L(-1) as Br, equivalent to 36 ng L(-1) of each enantiomer) than conventional ECD detector, it proved to be clearly superior in terms of selectivity. The relative potential and performance of the two compared methods for real-life analysis has been illustrated by the determination of enantiomers of bromocyclen in spiked tissue extracts of trout.
Molecular Characteristics of Mantle Cell Lymphoma Presenting with Clonal Plasma Cell Component
Visco, Carlo; Hoeller, Sylvia; Malik, Jeffrey T.; Xu-Monette, Zijun Y.; Wiggins, Michele L.; Liu, Jessica; Sanger, Warren G.; Liu, Zhongfeng; Chang, Julie; Ranheim, Erik A.; Gradowski, Joel F.; Serrrano, Sergio; Wang, Huan-You; Liu, Qingquan; Dave, Sandeep; Olsen, Brian; Gascoyne, Randy D.; Campo, Elias; Swerdlow, Steven H.; Chan, Wing C.; Tzankov, Alexander; Young, Ken H.
2011-01-01
The normal counterparts of mantle cell lymphoma (MCL) are naïve quiescent B-cells that have not been processed through the germinal center (GC). For this reason, while lymphomas arising from GC or post-GC B-cells often exhibit plasmacytic differentiation, MCL rarely presents with plasmacytic features. Seven cases of MCL with a monotypic plasma cell (PC) population were collected from six centers and studied by immunohistochemistry, FICTION (Fluorescence immunophenotyping and Interphase Cytogenetics as a Tool for the Investigation of Neoplasms), capillary gel electrophoresis, and restriction fragment length polymorphism of immunoglobulin heavy chain analysis (RFLP/IgH) of microdissections of each of the MCL and PC populations to assess their clonal relationship. Clinical presentation was rather unusual compared to typical MCL, with two cases arising from extranodal soft-tissues of the head. All MCL cases were morphologically and immunohistochemically typical, bearing the t(11;14)(q13;q32). In all cases PC populations were clonal. In 5 of the 7 cases, the MCL and PC clones showed identical restriction fragments, indicating a common clonal origin of the neoplastic populations. The two cases with clonal diversity denoted the coexistence of two different tumors in a composite lymphoma/plasma cell neoplasm. Our findings suggest that MCL can present with a PC component that is often clonally related to the lymphoma, representing a rare but unique biological variant of this tumor. PMID:21263238
Zahradnícková, Helena; Husek, Petr; Simek, Petr; Hartvich, Petr; Marsálek, Blahoslav; Holoubek, Ivan
2007-08-01
A rapid and simple method was developed for the determination of free amino acids (AAs) released from cyanobacteria. The procedure involves trapping of AAs from the centrifuged cyanobacterial culture fluid on a cation-exchange resin, their release together with the resin by direct treatment with the reaction medium, followed by immediate derivatization with a corresponding chloroformate. The extractive alkylation transfers the analytes into an organic phase, an aliquot of which is subjected to GC analysis. Identification and quantification of AAs was performed by GC/MS and GC/FID, respectively, using propyl chloroformate (PCF) as the derivatization reagent. For chiral analysis, the cyanobacteria extracts were treated with 2,2,3,3,3-pentafluoropropyl chloroformate (PFPCF) to create more volatile analytes. Separation of the AA enantiomers was accomplished on a Chirasil-Val capillary column and the D/L enantiomeric ratios were determined. AAs of cyanobacteria are considered to be important for the assessment of energy flow in an aquatic food web, nutrition value of cyanobacteria in a food web and for cell-cell communication within cyanobacteria. The highest levels of AAs were found in the summer period at the beginning of the season (July). In the September and October samples, the amount of AAs was lower, the number of D-AAs decreased and the D/L ratio was higher than in the July sample. Based on the obtained results it can be assumed that young populations excrete AAs in higher concentrations and a different composition compared to actively growing populations.
ENVIRONMENTAL ANALYTICAL CHEMISTRY OF ...
Within the scope of a number of emerging contaminant issues in environmental analysis, one area that has received a great deal of public interest has been the assessment of the role of pharmaceuticals and personal care products (PPCPs) as stressors and agents of change in ecosystems as well as their role in unplanned human exposure. The relationship between personal actions and the occurrence of PPCPs in the environment is clear-cut and comprehensible to the public. In this overview, we attempt to examine the separations aspect of the analytical approach to the vast array of potential analytes among this class of compounds. We also highlight the relationship between these compounds and endocrine disrupting compounds (EDCs) and between PPCPs and EDCs and the more traditional environmental analytes such as the persistent organic pollutants (POPs). Although the spectrum of chemical behavior extends from hydrophobic to hydrophilic, the current focus has shifted to moderately and highly polar analytes. Thus, emphasis on HPLC and LC/MS has grown and MS/MS has become a detection technique of choice with either electrospray ionization or atmospheric pressure chemical ionization. This contrasts markedly with the bench mark approach of capillary GC, GC/MS and electron ionization in traditional environmental analysis. The expansion of the analyte list has fostered new vigor in the development of environmental analytical chemistry, modernized the range of tools appli
Panja, Amrita; Chowdhury, Prosanto; Basu, Anupam
2016-09-01
We describe a novel C>T substitution at codon 53 of the HBB gene (HBB: c.161C>T). The proband was a transfusion-dependent β-thalassemia major (β-TM) patient. DNA was extracted and subsequently, DNA sequencing was done to detect the mutations on the HBB gene. Capillary zone electrophoresis (CZE) revealed the presence of an unknown peak. She inherited this mutation from her grandmother through her mother. This mutation exists in cis with the common β 0 mutation IVS-I-5 (G>C) (HBB: c.92+5G>C). The proband is homozygous for HBB: c.92+5G>C and needs monthly transfusions. On the other hand, her grandmother, mother and sister all possess this novel mutation cis with the heterozygous HBB: c.92+5G>C. They are carriers not thalassemic. This mutation produces the substitution β53(D4)Ala→Val; HBB: c.161C>T, a new structural hemoglobin (Hb) variant. As this variant was identified in a Bengali family from Paschim Midnapore district of West Bengal, India, it has been designated as Hb Midnapore. This variant has now been reported to the HbVar database.
NASA Astrophysics Data System (ADS)
Gauchotte-Lindsay, Caroline; McGregor, Laura; Richards, Phil; Kerr, Stephanie; Glenn, Aliyssa; Thomas, Russell; Kalin, Robert
2013-04-01
Comprehensive two-dimensional gas chromatography (GCxGC) is a recently developed analytical technique in which two capillary columns with different stationary phases are placed in series enabling planar resolution of the analytes. The resolution power of GCxGC is one order of magnitude higher than that of one dimension gas chromatography. Because of its high resolution capacity, the use of GCxGC for complex environmental samples such as crude oils, petroleum derivatives and polychlorinated biphenyls mixtures has rapidly grown in recent years. We developed a one-step method for the forensic analysis of coal tar dense non-aqueous phase liquids (DNAPLs) from former manufactured gas plant (FMGP) sites. Coal tar is the by-product of the gasification of coal for heating and lighting and it is composed of thousands of organic and inorganic compounds. Before the boom of natural gases and oils, most towns and cities had one or several manufactured gas plants that have, in many cases, left a devastating environmental print due to coal tar contamination. The fate of coal tar DNAPLs, which can persist in the environment for more than a hundred years, is therefore of crucial interest. The presented analytical method consists of a unique clean-up/ extraction stage by pressurized liquid extraction and a single analysis of its organic chemical composition using GCxGC coupled with time of flight mass spectrometry (TOFMS). The chemical fingerprinting is further improved by derivatisation by N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) of the tar compounds containing -OH functions such as alcohols and carboxylic acids. We present here how, using the logical order of elution in GCxGC-TOFMS system, 1) the identification of never before observed -OH containing compounds is possible and 2) the isomeric selectivity of an oxidation reaction on a DNAPL sample can be revealed. Using samples collected at various FMGP sites, we demonstrate how this GCxGC method enables the simultaneous uncovering of information on the source of the coal tar, particularly the coal gasification process it originates from, and on its fate once released in the subsurface, i.e. the nature of the transformations it underwent such as evaporation, water-washing, chemical reactions or biodegradation.
PCB congener analysis with Hall electrolytic conductivity detection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Edstrom, R.D.
1989-01-01
This work reports the development of an analytical methodology for the analysis of PCB congeners based on integrating relative retention data provided by other researchers. The retention data were transposed into a multiple retention marker system which provided good precision in the calculation of relative retention indices for PCB congener analysis. Analytical run times for the developed methodology were approximately one hour using a commercially available GC capillary column. A Tracor Model 700A Hall Electrolytic Conductivity Detector (HECD) was employed in the GC detection of Aroclor standards and environmental samples. Responses by the HECD provided good sensitivity and were reasonablymore » predictable. Ten response factors were calculated based on the molar chlorine content of each homolog group. Homolog distributions were determined for Aroclors 1016, 1221, 1232, 1242, 1248, 1254, 1260, 1262 along with binary and ternary mixtures of the same. These distributions were compared with distributions reported by other researchers using electron capture detection as well as chemical ionization mass spectrometric methodologies. Homolog distributions acquired by the HECD methodology showed good correlation with the previously mentioned methodologies. The developed analytical methodology was used in the analysis of bluefish (Pomatomas saltatrix) and weakfish (Cynoscion regalis) collected from the York River, lower James River and lower Chesapeake Bay in Virginia. Total PCB concentrations were calculated and homolog distributions were constructed from the acquired data. Increases in total PCB concentrations were found in the analyzed fish samples during the fall of 1985 collected from the lower James River and lower Chesapeake Bay.« less
Nitrous Oxide Explosive Hazards
2008-05-01
Supercritical Fluid Extraction- Capillary Gas Chromatography (SFE-GC) With a Conventional Split/Splitless Injection Port”, Journal of Chromatographic...Aromatic Hydrocarbons from Environmental Solids Using Supercritical Fluids ”, Steven B. Hawthorne and David J. Miller, Anal. Chem. 59, pp 1705-1708, 1987...Katayama, T., J. Supercrit . Fluids , 1990, 3, 78-84. 30. “ Supercritical Fluid Extraction of Fungal Oil Using CO2, N2O, CHF3, and SF6”, Keiji Sakaki
If You Were a Molecule in a Chromatography Column, What Would You See?
ERIC Educational Resources Information Center
Mattice, John
2008-01-01
To visualize what takes place in a chromatography column, enlarge the molecules to human size and expand the columns to keep the ratio of size of molecule to size of column the same. If we were molecules, what would the columns be like? A typical gas chromatography (GC) capillary column would be 50 x 10 [superscript 6] 6 km (31 million mi) long,…
Kojima, T; Ishii, A; Watanabe-Suzuki, K; Kurihara, R; Seno, H; Kumazawa, T; Suzuki, O; Katsumata, Y
2001-10-05
Four general anaesthetics, sevoflurane, isoflurane, enflurane and halothane, in human whole blood, have been found measurable with very high sensitivity by capillary gas chromatography-flame ionization detection (GC-FID) with cryogenic oven trapping upon injection of headspace (HS) vapor sample. To a 7-ml vial, containing 0.48 ml of distilled water and 20 microl of internal standard solution (5 microg), a 0.5-ml of whole blood sample spiked with or without anaesthetics, was added, and the mixture was heated at 55 degrees C for 15 min. A measure of 10 ml HS vapor was injected into the GC in the splitless mode at -40 degrees C oven temperature, which was programmed up to 250 degrees C. All four peaks were clearly separated; no impurity peaks were found among their peaks. Their extraction efficiencies were about 10%. The calibration curves showed good linearity in the range of 0.5-20 microg/ml; their detection limits were 10-100 ng/ml, which are almost comparable to those by previous reports. The coefficients of intra-day and day-to-day variations were 6.5-9.8 and 7.3-17.2%, respectively. Isoflurane or enflurane was also measured from whole blood samples in which three volunteers inhaled each compound.
Dumasia, M C; Houghton, E; Hyde, W; Greulich, D; Nelson, T; Peterson, Jackie
2002-02-05
Studies related to the in vivo biotransforrmation and urinary excretion of fenspiride hydrochloride in the horse are described. After oral administration, the drug is metabolised by both phase I functionalisation and phase II conjugation pathways. Following enzymatic deconjugation, fenspiride and its phase I metabolites were isolated from post-administration biofluids using bonded co-polymeric mixed mode solid-phase extraction cartridges to isolate the basic compounds. Following trimethylsilylation (TMS), the parent drug and metabolites were identified by capillary gas chromatography-mass spectrometry (GC-MS). Fenspiride (A) and seven metabolites (B-->G) arising from oxidation on both the aromatic and heterocyclic substructures were detected in urine. The positive ion electron ionisation mass spectra of the TMS derivatives of fenspiride and its metabolites provided useful information on its metabolism. Positive ion methane chemical ionisation-GC-MS of the derivatives provided both derivatised molecular mass and structural information. Unchanged fenspiride can be detected in post-administration plasma and urine samples for up to 24 h. Maximum urinary levels of 100-200 ng ml(-1) were observed between 3 and 5 h after administration. After enzymatic deconjugation, the major phenolic metabolite (G) can be detected in urine for up to 72 h. This metabolite is the analyte of choice in the GC-MS screening of post-race equine urine samples for detection of fenspiride use. However, a distinct difference was observed in the urinary excretion of this metabolite between the thoroughbred horses used in UK study and the quarterbred and standardbred horses used for the USA administrations.
Wu, Pinggu; Zhang, Liqun; Shen, Xianghong; Wang, Liyuan; Zou, Yan; Zhang, Jing; Tan, Ying; Tang, Jun; Ma, Bingjie; Pan, Xiaodong; Jiang, Wei
2015-01-01
A sensitive and rapid analytical method based on alkaline diatomaceous earth extraction followed by GC/MS was developed for the quantitative determination of the toxic contaminant ethyl carbamate (EC) in yellow rice wines. The optimal extraction conditions were investigated. With the application of diatomaceous earth extraction, the damage of organic acids to the capillary column was greatly reduced. By using d5-EC as an internal standard for quantitative analysis of EC, the linearity of the calibration curves was good between 10 and 1000 ng/mL. The LOD and LOQ were 1.7 and 5.0 μg/kg, respectively. The spiked level of EC was 5.0-300 μg/kg, and the average recovery of the spikes was between 78.4 and 98.2%, with an RSD between 4.3 and 8.3%. Upon validation by five laboratories when spiked with 50, 100, and 300 μg/kg, the average respective recoveries were 102.9, 102.2, and 98.7% with a RSD between 0.7 and 8.1%. The validation results demonstrated that the method is fast, simple, selective, and suitable for the determination of EC in yellow rice wines.
Fardin-Kia, Ali Reza; Delmonte, Pierluigi; Kramer, John K G; Jahreis, Gerhard; Kuhnt, Katrin; Santercole, Viviana; Rader, Jeanne I
2013-12-01
The fatty acids contained in marine oils or products are traditionally analyzed by gas chromatography using capillary columns coated with polyethylene glycol phases. Recent reports indicate that 100 % cyanopropyl siloxane phases should also be used when the analyzed samples contain trans fatty acids. We investigated the separation of the fatty acid methyl esters prepared from menhaden oil using the more polar SLB-IL111 (200 m × 0.25 mm) ionic liquid capillary column and the chromatographic conditions previously optimized for the separation of the complex mixture of fatty acid methyl esters prepared from milk fat. Identifications of fatty acids were achieved by applying Ag(+)-HPLC fractionation and GC-TOF/MS analysis in CI(+) mode with isobutane as the ionization reagent. Calculation of equivalent chain lengths confirmed the assignment of double bond positions. This methodology allowed the identification of 125 fatty acids in menhaden oil, including isoprenoid and furanoid fatty acids, and the novel 7-methyl-6-hexadecenoic and 7-methyl-6-octadecenoic fatty acids. The chromatographic conditions applied in this study showed the potential of separating in a single 90-min analysis, among others, the short chain and trans fatty acids contained in dairy products, and the polyunsaturated fatty acids contained in marine products.
Analysis of short-chain fatty acids in human feces: A scoping review.
Primec, Maša; Mičetić-Turk, Dušanka; Langerholc, Tomaž
2017-06-01
Short-chain fatty acids (SCFAs) play a crucial role in maintaining homeostasis in humans, therefore the importance of a good and reliable SCFAs analytical detection has raised a lot in the past few years. The aim of this scoping review is to show the trends in the development of different methods of SCFAs analysis in feces, based on the literature published in the last eleven years in all major indexing databases. The search criteria included analytical quantification techniques of SCFAs in different human clinical and in vivo studies. SCFAs analysis is still predominantly performed using gas chromatography (GC), followed by high performance liquid chromatography (HPLC), nuclear magnetic resonance (NMR) and capillary electrophoresis (CE). Performances, drawbacks and advantages of these methods are discussed, especially in the light of choosing a proper pretreatment, as feces is a complex biological material. Further optimization to develop a simple, cost effective and robust method for routine use is needed. Copyright © 2017 Elsevier Inc. All rights reserved.
Tarifa, Anamary; Almirall, José R
2015-05-01
A rapid method for the characterization of both organic and inorganic components of gunshot residues (GSR) is proposed as an alternative tool to facilitate the identification of a suspected shooter. In this study, two fast screening methods were developed and optimized for the detection of organic compounds and inorganic components indicative of GSR presence on the hands of shooters and non-shooters. The proposed methods consist of headspace extraction of volatile organic compounds using a capillary microextraction of volatiles (CMV) device previously reported as a high-efficiency sampler followed by detection by GC-MS. This novel sampling technique has the potential to yield fast results (<2min sampling) and high sensitivity capable of detecting 3ng of diphenylamine (DPA) and 8ng of nitroglycerine (NG). Direct analysis of the headspace of over 50 swabs collected from the hands of suspected shooters (and non-shooters) provides information regarding VOCs present on their hands. In addition, a fast laser induced breakdown spectroscopy (LIBS) screening method for the detection of the inorganic components indicative of the presence of GSR (Sb, Pb and Ba) is described. The sampling method for the inorganics consists of liquid extraction of the target elements from the same cotton swabs (previously analyzed for VOCs) and an additional 30 swab samples followed by spiking 1μL of the extract solution onto a Teflon disk and then analyzed by LIBS. Advantages of LIBS include fast analysis (~12s per sample) and high selectivity and sensitivity, with expected LODs 0.1-18ng for each of the target elements after sampling. The analytical performance of the LIBS method is also compared to previously reported methods (inductively coupled plasma-optical emission spectroscopy). The combination of fast CMV sampling, unambiguous organic compound identification with GC-MS and fast LIBS analysis provides the basis for a new comprehensive screening method for GSR. Copyright © 2015 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pitts, F.N. Jr.; Allen, R.E.; Aniline, O.
By utilizing a glass capillary gas chromatographic nitrogen detector (GC2-N) method specific for phencyclidine (PCP) and sensitive to pg/mL in blood or urine samples, we have demonstrated occupational intoxication of law enforcement personnel charged with handling confiscated illegal PCP preparations. Further, we have demonstrated persistence of PCP in blood and urine for at least 6 months after the last known occupational exposure in one officer. Some aspects of the PCP problem are outlined, and possible mechanisms of the occupational intoxication are discussed.
Petrović, Marinko; Debeljak, Zeljko; Blazević, Nikola
2005-09-15
The gas chromatography (GC) method for enantioseparation of well-known non-steroidal anti-inflammatory drugs ibuprofen, fenoprofen and ketoprofen methyl esters mixture was developed. Best enantioseparation was performed on capillary column with heptakis-(2,3-di-O-methyl-6-O-t-butyldimethyl-silyl)-beta-cyclodextrin stationary phase and hydrogen used as a carrier gas. Initial temperature, program rate and carrier pressure were optimized to obtain best resolution between enantiomers.
Design for gas chromatography-corona discharge-ion mobility spectrometry.
Jafari, Mohammad T; Saraji, Mohammad; Sherafatmand, Hossein
2012-11-20
A corona discharge ionization-ion mobility spectrometry (CD-IMS) with a novel sample inlet system was designed and constructed as a detector for capillary gas chromatography. In this design, a hollow needle was used instead of a solid needle which is commonly used for corona discharge creation, helping us to have direct axial interfacing for GC-IMS. The capillary column was passed through the needle, resulting in a reaction of effluents with reactant ions on the upstream side of the corona discharge ionization source. Using this sample introduction design, higher ionization efficiency was achieved relative to the entrance direction through the side of the drift tube. In addition, the volume of the ionization region was reduced to minimize the resistance time of compounds in the ionization source, increasing chromatographic resolution of the instrument. The effects of various parameters such as drift gas flow, makeup gas flow, and column tip position inside the needle were investigated. The designed instrument was exhaustively validated in terms of sensitivity, resolution, and reproducibility by analyzing the standard solutions of methyl isobutyl ketone, heptanone, nonanone, and acetophenone as the test compounds. The results obtained by CD-IMS detector were compared with those of the flame ionization detector, which revealed the capability of the proposed GC-IMS for two-dimensional separation (based on the retention time and drift time information) and identification of an analyte in complex matrixes.
Sharaf, Maged H M; Stiff, Dwight D
2004-06-29
A method for the quantitation of guaifenesin in human serum has been developed and validated. The procedure involves liquid-liquid extraction of the serum sample in the presence of mephenesin as an internal standard, followed by derivatization and analysis using capillary gas chromatography (GC) and electron capture detection (ECD). Different solvents were tested for extraction of guaifenesin from serum. n-Hexane/dichloromethane (1:1, v/v) gave the highest recovery and the lowest background and was chosen as the extraction solvent. After extraction, the residue of guaifenesin was derivatized at 60 degrees C for 30 min, with trifluoroacetic acid anhydride (TFAA) in toluene in the presence of pyridine. Excess trifluoroacetic acid anhydride was removed using dilute solution of ammonium hydroxide. The method proved to be linear over the range of 25.0-1000 ng/ml. Recovery of guaifenesin from spiked samples was consistent, averaging 75.5% at 50.0 ng/ml with a range of 72.0-80.0% (N = 8 determinations) and averaging 78% at 800 ng/ml with a range of 76.0-81.0% (N = 8 determinations). The internal standard recovery was also consistent averaging 72.8% with a range of 67.0-76.0% (N = 16 determinations). Copyright 2004 Elsevier B.V.
NASA Astrophysics Data System (ADS)
Yassaa, Noureddine; Williams, Jonathan
A portable dynamic air sampler (PDAS) using a porous polymer solid-phase microextraction (SPME) fibre has been validated for the determination of biogenic enantiomeric and non-enantiomeric monoterpenes in air. These compounds were adsorbed in the field, and then thermally desorbed at 250 °C in a gas chromatograph injector port connected via a β-cyclodextrin capillary separating column to a mass spectrometer. The optimized method has been applied for investigating the emissions of enantiomeric monoterpenes from Pseudotsuga menziesii (Douglas-fir), Rosmarinus officinalis (Rosemary) and Lavandula lanata (Lavender) which were selected as representative of coniferous trees and aromatic plants, respectively. The enantiomers of α-pinene, sabinene, camphene, δ-3-carene, β-pinene, limonene, β-phellandrene, 4-carene and camphor were successfully determined in the emissions from the three plants. While Douglas-fir showed a strong predominance toward (-)-enantiomers, Rosemary and Lavender demonstrated a large variation in enantiomeric distribution of monoterpenes. The simplicity, rapidity and sensitivity of dynamic sampling with porous polymer coated SPME fibres coupled to chiral capillary gas chromatography/mass spectrometry (GC/MS) makes this method potentially useful for in-field investigations of atmosphere-biosphere interactions and studies of optically explicit atmospheric chemistry.
Kawata, Jyunichi; Kameda, Munekazu; Miyazawa, Mitsuo
2008-04-01
The composition of the volatile oil from Lithospermi Radix, the dried roots of Lithospermum erythrorhizon (Boraginaceae), has been investigated by capillary GC and GC-MS. To investigate the anti-inflammatory activity of the oil, in-vitro inhibition of ovine cyclooxygenase-1 and 2 (COX-1 and COX-2) activity by the oil was studied. Fifty-four components of the oil were identified, representing 92.74% of the oil. The main components were 2-methylbutanoic acid (21.50%), 3-methylbutanoic acid (12.61%), 2-methylpropanoic acid (8.99%), methyl linoleate (8.76%), methyl oleate (6.27%), methyl palmitate (6.06%), and 2-methyl-2-butenoic acid (5.74%). Highly selective COX-2 inhibition was observed; at 50 microg/ml the oil inhibited 38.8% of COX-2 activity.
Lindley, C.E.; Stewart, J.T.; Sandstrom, M.W.
1996-01-01
A sensitive and reliable gas chromatographic/mass spectrometric (GC/MS) method for determining acetochlor in environmental water samples was developed. The method involves automated extraction of the herbicide from a filtered 1 L water sample through a C18 solid-phase extraction column, elution from the column with hexane-isopropyl alcohol (3 + 1), and concentration of the extract with nitrogen gas. The herbicide is quantitated by capillary/column GC/MS with selected-ion monitoring of 3 characteristic ions. The single-operator method detection limit for reagent water samples is 0.0015 ??g/L. Mean recoveries ranged from about 92 to 115% for 3 water matrixes fortified at 0.05 and 0.5 ??g/L. Average single-operator precision, over the course of 1 week, was better than 5%.
Pietrogrande, Maria Chiara
2013-10-01
Traces of prebiotic amino acids, i.e., the building blocks of proteins, are excellent biomarkers that could provide evidence of extinct or extant life in extra-terrestrial environments. In particular, characterization of the enantiomeric excess of amino acids gives relevant information about the biotic or abiotic origin of molecules, because it is generally assumed that life elsewhere could be based on either L or D amino acids, but not both. The analytical procedures used in in-situ space missions for chiral discrimination of amino acids must meet severe requirements imposed by flight conditions: short analysis time, low energy consumption, robustness, storage for long periods under extreme conditions, high efficiency and sensitivity, automation, and remote-control operation. Such methods are based on gas chromatography, high-pressure liquid chromatography, and capillary electrophoresis, usually coupled with mass spectrometry; of these, gas chromatography-mass spectrometry (GC-MS) is the only such combination yet used in space missions. Preliminary in-situ sample derivatization is required before GC-MS analysis to convert amino acids into volatile and thermally stable compounds. The silylation reagent most commonly used, N-(tert-butyldimethylsilyl)-N-methyltrifluoroacetamide, is unsuitable for detection of homochirality, and alternative derivatization techniques have been developed that preserve the stereochemical configuration of the original compounds and are compatible with spaceflight conditions. These include the reagent N,N-dimethylformamide dimethylacetal, which has already been used in the Rosetta mission, a mixture of alkyl chloroformate, ethanol, and pyridine, a mixture of perfluorinated anhydrides and perfluoro alcohols, and hexafluoroacetone, the first gaseous derivatizing agent. In all the space instruments, solvent extraction of organic matter and chemical derivatization have been combined in a single automatic and remote-controlled procedure in a chemical reactor. Liquid-based separation systems have been used in space missions. In particular, microchip capillary electrophoresis, based on microfluidic lab-on-a-chip systems, enables high-performance chemical analysis of amino acids with low mass and volume equipment and low power and reagent consumption. Coupling with laser-induced fluorescence detectors results in ultra-low limits of detection. This critical review describes applications of the on-board instruments used in the Rosetta mission to comets and in the more recent Mars exploration program, i.e., the Mars Science Laboratory and ExoMars missions.
Occupational exposure to Polycyclic Aromatic Hydrocarbons in wood dust
NASA Astrophysics Data System (ADS)
Huynh, C. K.; Schüpfer, P.; Boiteux, P.
2009-02-01
Sino-nasal cancer (SNC) represents approximately 3% of Oto-Rhino-Laryngology (ORL) cancers. Adenocarcinoma SNC is an acknowledged occupational disease affecting certain specialized workers such as joiners and cabinetmakers. The high proportion of woodworkers contracting a SNC, subjected to an estimated risk 50 to 100 times higher than that affecting the general population, has suggested various study paths to possible causes such as tannin in hardwood, formaldehyde in plywood and benzo(a)pyrene produced by wood when overheated by cutting tools. It is acknowledged that tannin does not cause cancer to workers exposed to tea dust. Apart from being an irritant, formaldehyde is also classified as carcinogenic. The path involving carcinogenic Polycyclic Aromatic Hydrocarbons (PAHs) emitted by overheated wood is attractive. In this study, we measured the particle size and PAHs content in dust emitted by the processing of wood in an experimental chamber, and in field situation. Quantification of 16 PAHs is carried out by capillary GC-ion trap Mass Spectrometric analysis (GC-MS). The materials tested are rough fir tree, oak, impregnated polyurethane (PU) oak. The wood dust contains carcinogenic PAHs at the level of μg.g-1 or ppm. During sanding operations, the PU varnish-impregnated wood produces 100 times more PAHs in dust than the unfinished wood.
NASA Astrophysics Data System (ADS)
Yassaa, N.; Custer, T.; Song, W.; Pech, F.; Kesselmeier, J.; Williams, J.
2010-08-01
A solid-phase microextraction (HS-SPME) and gas chromatography/mass spectrometry (GC/MS) system has been developed for quantifying enantiomeric and nonenantiomeric monoterpenes in plant chamber studies and ambient air. Performance of this system was checked using a capillary diffusion system to produce monoterpene standards. The adsorption efficiency, competitive adsorption and chromatographic peak resolution of monoterpene enantiomer pairs were compared for three SPME fibre coatings: 75 μm Carboxen-PDMS (CAR-PDMS), 50/30 μm, divinylbenzene-carboxen-polydimethylsiloxane (DVB-CAR-PDMS) and 65 μm divinylbenzene-polydimethyl-siloxane (DVB-PDMS). Key parameters such as the linearity and reproducibility of the SPME system have been investigated in this work. The best compromise between the enantiomeric separation of monoterpenes and competitive adsorption of the isoprenoids on the solid SPME fibre coating was found for DVB-PDMS fibres. The optimum conditions using DVB-PDMS fibres were applied to measure the exchange rates of monoterpenes in the emission of Quercus ilex using a laboratory whole plant enclosure under light and dark conditions, as well as in ambient air. With 592 and 223 ng m-2 s-1, respectively, β-myrcene and limonene were the predominant monoterpenes in the emission of Q. ilex. These values were closely comparable to those obtained using a zNose and cartridge GC-FID systems.
NASA Astrophysics Data System (ADS)
Yassaa, N.; Custer, T.; Song, W.; Pech, F.; Kesselmeier, J.; Williams, J.
2010-11-01
A headspace solid-phase microextraction (HS-SPME) and gas chromatography/mass spectrometry (GC/MS) system has been developed for quantifying enantiomeric and nonenantiomeric monoterpenes in plant chamber studies and ambient air. Performance of this system was checked using a capillary diffusion system to produce monoterpene standards. The adsorption efficiency, competitive adsorption and chromatographic peak resolution of monoterpene enantiomer pairs were compared for three SPME fibre coatings: 75 μm Carboxen-PDMS (CAR-PDMS), 50/30 μm divinylbenzene-carboxen-polydimethylsiloxane (DVB-CAR-PDMS) and 65 μm divinylbenzene-polydimethylsiloxane (DVB-PDMS). Key parameters such as the linearity and reproducibility of the SPME system have been investigated in this work. The best compromise between the enantiomeric separation of monoterpenes and competitive adsorption of the isoprenoids on the solid SPME fibre coating was found for DVB-PDMS fibres. The optimum conditions using DVB-PDMS fibres were applied to measure the exchange rates of monoterpenes in the emission of Quercus ilex using a laboratory whole plant enclosure under light and dark conditions, as well as in ambient air. With 592 and 223 ng m-2 s-1 respectively, β-myrcene and limonene were the predominant monoterpenes in the emission of Q. ilex. These values were closely comparable to those obtained using a zNose and cartridge GC-FID systems.
Zapadlo, Michal; Krupcík, Ján; Májek, Pavel; Armstrong, Daniel W; Sandra, Pat
2010-09-10
The orthogonality of three columns coupled in two series was studied for the congener specific comprehensive two-dimensional GC separation of polychlorinated biphenyls (PCBs). A non-polar capillary column coated with poly(5%-phenyl-95%-methyl)siloxane was used as the first ((1)D) column in both series. A polar capillary column coated with 70% cyanopropyl-polysilphenylene-siloxane or a capillary column coated with the ionic liquid 1,12-di(tripropylphosphonium)dodecane bis(trifluoromethane-sulfonyl)imide were used as the second ((2)D) columns. Nine multi-congener standard PCB solutions containing subsets of all native 209 PCBs, a mixture of 209 PCBs as well as Aroclor 1242 and 1260 formulations were used to study the orthogonality of both column series. Retention times of the corresponding PCB congeners on (1)D and (2)D columns were used to construct retention time dependences (apex plots) for assessing orthogonality of both columns coupled in series. For a visual assessment of the peak density of PCBs congeners on a retention plane, 2D images were compared. The degree of orthogonality of both column series was, along the visual assessment of distribution of PCBs on the retention plane, evaluated also by Pearson's correlation coefficient, which was found by correlation of retention times t(R,i,2D) and t(R,i,1D) of corresponding PCB congeners on both column series. It was demonstrated that the apolar+ionic liquid column series is almost orthogonal both for the 2D separation of PCBs present in Aroclor 1242 and 1260 formulations as well as for the separation of all of 209 PCBs. All toxic, dioxin-like PCBs, with the exception of PCB 118 that overlaps with PCB 106, were resolved by the apolar/ionic liquid series while on the apolar/polar column series three toxic PCBs overlapped (105+127, 81+148 and 118+106). Copyright 2010 Elsevier B.V. All rights reserved.
Identification of natural indigo in historical textiles by GC-MS.
Degani, Laura; Riedo, Chiara; Chiantore, Oscar
2015-02-01
The possibility of successfully applying a common GC-MS procedure for identification in one step of all types of dyes from plants of unknown origin and from historical objects is particularly attractive due to the high separation efficiency of the capillary columns, the MS detection sensitivity and the reproducibility of results. In this work, GC-MS analysis, previously and successfully used for the characterization of anthraquinones, flavonoids and tannins from plant extracts and historical samples, has been tested on indigoid dyestuffs. An analytical procedure based on the silylating agent N,O-bis-(trimethylsilyl)trifluoroacetamide (BSTFA) with 1% trimethylchlorosilane (TMCS) was applied to pure molecules of indigotin and indirubin and to plant extracts of Indigofera tinctoria L. and Isatis tinctoria L. Preliminary tests have been done to establish the chromatographic conditions and the derivatization amounts most suitable for the simultaneous detection of indigoid molecules and of the other natural compounds, such as fatty acids, carboxylic acids and sugars, contained within the plant extracts. In order to assess the capacity and the sensitivity of the analytical procedure in typical archaeometric applications, wool samples dyed in the laboratory with indigo were analysed by mimicking the sample amounts typically available with historical objects. The electron ionization (EI) spectra of the main silylated derivatives of indigoid molecules obtained in this way constitute the necessary data set for the characterization of natural extracts and historical works of art. Subsequently, the procedure has been applied to historical samples for the detection of indigo and of other dyestuffs eventually contained in samples. Additional information, useful for restoration and preservation of works of art, could be also obtained on the nature of stains and smudges present on the sampled textile material. The GC-MS method turns out to be an efficient and fast analytical tool also for the identification of natural indigo in plants and textile artefacts, providing results complementary to those from high-performance liquid chromatography (HPLC).
Garrido-López, Alvaro; Esquiu, Vanesa; Tena, María Teresa
2007-05-25
Polymers require the use of some slip agents, such as oleamide and erucamide, in order to reduce their friction coefficient and to make films easier to handle. In this communication, three analytical methods consisting in pressurized liquid extraction (PLE) and gas chromatography (GC) are used to determine oleamide and erucamide in polyethylene films. The sample was extracted with pure isopropanol (two times) at 105 degrees C for 16 min. Then, the liquid extract containing oleamide and erucamide was analyzed by GC and three different detection systems: flame ionization detector (FID), thermoionic selective detector (TSD) and ion-trap mass spectrometry detector (MSD). Oleamide and erucamide were separated using a 30 m x 0.25 mm (I.D.) 5% phenyl-95% dimethyl-polysiloxane capillary column in 12 min. The chromatographic methods were characterized and compared in terms of repeatability, linearity and sensitivity. The GC-FID and GC-TSD methods were linear up to about 60 microg ml(-1), whereas the linear range for the GC-MSD method was shorter, from 20.5 to 42 microg ml(-1). LODs identified with GC-MSD were two times higher than those identified with the other two methods. Repeatability values (expressed as relative standard deviation) of less than 2.5% were found for FID and TSD but they were above 10% for MSD. Finally, each method was applied to determine the content of erucamide and oleamide in several polyethylene films and the results obtained were compared with those obtained from the nitrogen content measured by pyrolysis and gas-phase chemiluminescence. No significant differences were observed between the results of the methods.
Ohrui, Y; Nagoya, T; Kurimata, N; Sodeyama, M; Seto, Y
2017-07-01
A field-portable gas chromatography-mass spectrometry (GC-MS) system (Hapsite ER) was evaluated for the detection of nonvolatile V-type nerve agents (VX and Russian VX (RVX)) in the vapor phase. The Hapsite ER system consists of a Tri-Bed concentrator gas sampler, a nonpolar low thermal-mass capillary GC column and a hydrophobic membrane-interfaced electron ionization quadrupole mass spectrometer evacuated by a non-evaporative getter pump. The GC-MS system was attached to a VX-G fluoridating conversion tube containing silver nitrate and potassium fluoride. Sample vapors of VX and RVX were converted into O-ethyl methylphosphonofluoridate (EtGB) and O-isobutyl methylphosphonofluoridate (iBuGB), respectively. These fluoridated derivatives were detected within 10 min. No compounds were detected when the VX and RVX samples were analyzed without the conversion tube. A vapor sample of tabun (GA) was analyzed, in which GA and O-ethyl N,N-dimethylphosphoramidofluoridate were detected. The molar recovery percentages of EtGB and iBuGB from VX and RVX vapors varied from 0.3 to 17%, which was attributed to variations in the vaporization efficiency of the glass vapor container. The conversion efficiencies of the VX-G conversion tube for VX and RVX to their phosphonate derivatives were estimated to be 40%. VX and RVX vapors were detected at concentrations as low as 0.3 mg m -3 . Gasoline vapor was found to interfere with the analyses of VX and RVX. In the presence of 160 mg m -3 gasoline, the detection limits of VX and RVX vapor were increased to 20 mg m -3 . Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Gu, Zhi-Yuan; Yang, Cheng-Xiong; Chang, Na; Yan, Xiu-Ping
2012-05-15
In modern analytical chemistry researchers pursue novel materials to meet analytical challenges such as improvements in sensitivity, selectivity, and detection limit. Metal-organic frameworks (MOFs) are an emerging class of microporous materials, and their unusual properties such as high surface area, good thermal stability, uniform structured nanoscale cavities, and the availability of in-pore functionality and outer-surface modification are attractive for diverse analytical applications. This Account summarizes our research on the analytical applications of MOFs ranging from sampling to chromatographic separation. MOFs have been either directly used or engineered to meet the demands of various analytical applications. Bulk MOFs with microsized crystals are convenient sorbents for direct application to in-field sampling and solid-phase extraction. Quartz tubes packed with MOF-5 have shown excellent stability, adsorption efficiency, and reproducibility for in-field sampling and trapping of atmospheric formaldehyde. The 2D copper(II) isonicotinate packed microcolumn has demonstrated large enhancement factors and good shape- and size-selectivity when applied to on-line solid-phase extraction of polycyclic aromatic hydrocarbons in water samples. We have explored the molecular sieving effect of MOFs for the efficient enrichment of peptides with simultaneous exclusion of proteins from biological fluids. These results show promise for the future of MOFs in peptidomics research. Moreover, nanosized MOFs and engineered thin films of MOFs are promising materials as novel coatings for solid-phase microextraction. We have developed an in situ hydrothermal growth approach to fabricate thin films of MOF-199 on etched stainless steel wire for solid-phase microextraction of volatile benzene homologues with large enhancement factors and wide linearity. Their high thermal stability and easy-to-engineer nanocrystals make MOFs attractive as new stationary phases to fabricate MOF-coated capillaries for high-resolution gas chromatography (GC). We have explored a dynamic coating approach to fabricate a MOF-coated capillary for the GC separation of important raw chemicals and persistent organic pollutants with high resolution and excellent selectivity. We have combined a MOF-coated fiber for solid-phase microextraction with a MOF-coated capillary for GC separation, which provides an effective MOF-based tandem molecular sieve platform for selective microextraction and high-resolution GC separation of target analytes in complex samples. Microsized MOFs with good solvent stability are attractive stationary phases for high-performance liquid chromatography (HPLC). These materials have shown high resolution and good selectivity and reproducibility in both the normal-phase HPLC separation of fullerenes and substituted aromatics on MIL-101 packed columns and position isomers on a MIL-53(Al) packed column and the reversed-phase HPLC separation of a wide range of analytes from nonpolar to polar and acidic to basic solutes. Despite the above achievements, further exploration of MOFs in analytical chemistry is needed. Especially, analytical application-oriented engineering of MOFs is imperative for specific applications.
Rothenbacher, Thorsten; Schwack, Wolfgang
2009-01-01
Plastic packaging materials may release compounds into packed foodstuffs. To identify potential migrants of toxicological concern, resins, and multilayer foils (mainly polyethylene) intended for the production of food contact materials were extracted and analyzed by GC/mass spectrometry. To identify even compounds of low concentrations, AMDIS software was used and data evaluation was safeguarded by the Kovats retention index (RI) system. In this way, 46 compounds were identified as possible migrants. The expert structure-activity relationship software DEREK for Windows was utilized to evaluate all identified substances in terms of carcinogenicity, genotoxicity, thyroid toxicity, and miscellaneous endpoints for humans. Additionally, a literature search for these compounds was performed with Sci-Finder, but relevant data were missing for 28 substances. Seven compounds with adverse toxicological effects were identified. In addition, the RIs of 24 commercial additive standards, measured with a GC capillary column of intermediate polarity, are given.
Lin, Y W; Hee, S S
1998-07-24
A rapid, reliable and effective method for direct determination of the inert components, manufacturing by-products of the pesticide, and active ingredient in two malathion formulations has been established using capillary gas chromatography-mass spectrometry (GC-MS) with the internal standard method. The C2-, C3-, and C4-alkylbenzenes, the major pesticide manufacturing by-products (O,O,S-trimethylthionophosphate, diethyl maleate and O,O,O-trimethylthionophosphate), and malathion were resolved, and quantified in the same chromatogram. Structural identification was based on MS total ion current data, comparison of GC retention times with those of authentic standards, and retention indices. O,O,S-Trimethylthionophosphate was quantified at 3.57 +/- 0.31% (w/w) in one malathion formulation. While the malathion contents were within specifications for both formulations, the total alkylbenzene contents were not.
Hu, Junpeng; Jia, Mengmeng; Zhu, Liang
2018-04-18
The essential oil obtained from Wedelia urticifolia growing in Hunan Province, China, was analyzed for the first time by capillary GC and GC-MS. A total of 67 constituents, representing 98.68% in essential oil were identified. The major constituents of the oil were: α-pinene (8.85%), limonene (6.38%), carvacrol (6.15%), caryophyllene (6.08%), spathulenol (5.49%), sabinene (5.36%), camphor (4.34%). Antimicrobial potential of oil against bacterial strains (Pseudomonas aeruginosa, Escherichia coli and Bacillus subtilis, and Staphylococcus aureus), yeast strains (Hansenula anomala and Saccharomy cescerevisiae) and molds (Aspergillus niger, Chaetomium globosum, Mucor racemosus, and Monascus anka) was determined by disc diffusion method and broth micro dilution method, respectively. The oil exhibited promising antimicrobial effect as a diameter of zones of inhibition (16.8-24.9 mm). Minimum inhibitory concentration values of oil were ranged 62.5-1000 μg/mL.
NASA Astrophysics Data System (ADS)
Wieczorek, Piotr; Ligor, Magdalena; Buszewski, Bogusław
Electromigration techniques, including capillary electrophoresis (CE), are widely used for separation and identification of compounds present in food products. These techniques may also be considered as alternate and complementary with respect to commonly used analytical techniques, such as high-performance liquid chromatography (HPLC), or gas chromatography (GC). Applications of CE concern the determination of high-molecular compounds, like polyphenols, including flavonoids, pigments, vitamins, food additives (preservatives, antioxidants, sweeteners, artificial pigments) are presented. Also, the method developed for the determination of proteins and peptides composed of amino acids, which are basic components of food products, are studied. Other substances such as carbohydrates, nucleic acids, biogenic amines, natural toxins, and other contaminations including pesticides and antibiotics are discussed. The possibility of CE application in food control laboratories, where analysis of the composition of food and food products are conducted, is of great importance. CE technique may be used during the control of technological processes in the food industry and for the identification of numerous compounds present in food. Due to the numerous advantages of the CE technique it is successfully used in routine food analysis.
Rezk, Mamdouh R; Abd El-Aleem, Abd El-Aziz B; Khalile, Shaban M; El-Naggar, Omneya K
2018-03-01
A sensitive gas chromatographic (GC) GC method has been developed for the determination of diazinon and chlorpyrifos residues in lavender and rosemary leaves. The developed method consists of blending weighed samples of chopped leaves with sodium sulfate as the dehydrating agent, extraction with ethyl acetate, filtration, evaporation with a rotary evaporator, and, finally, capillary GC determination of the pesticides. The recoveries of the method were greater than 90%, and the LOQ was less than 0.1 µg/mL. The method was applied to determine the rate of disappearance of diazinon and chlorpyrifos from lavender and rosemary leaves pretreated with the studied pesticides. The half-life values (t1/2) of diazinon were found to be 5.93 and 6.35 days for lavender and rosemary leaves, respectively, whereas the t1/2 values of chlorpyrifos were calculated to be 7.86 and 9.52 days for lavender and rosemary leaves, respectively. The safe harvest interval (preharvest interval; PHI) was suggested to be after 21 and 24 days for diazinon and chlorpyrifos, respectively. The PHI refers to the amount of time that must lapse (in days) after a pesticide application before a crop can be cut.
Kannenberg, Frank; Nofer, Jerzy-Roch; Schulte, Erhard; Reunert, Janine; Marquardt, Thorsten; Fobker, Manfred
2017-05-01
Niemann-Pick type C (NPC) is a neurological disease caused by an intracellular cholesterol accumulation. Cholesterol oxidation product cholestane-3β,5α,6β-triol (C-triol) serves as diagnostic biomarker for NPC, but its measurement in the routine laboratory remains difficult. We developed an isotope dilution gas chromatography-mass spectrometry (GC-MS) method permitting screening for NPC in plasma. 1440 plasma samples obtained from clinically suspicious patients were subjected to alkaline saponification. C-triol was extracted with carbon tetrachloride, transformed into the trimethylsilylethers, separated on a fused silica capillary column with a nonpolar silicone stationary phase, and analyzed by GC-MS. NPC diagnosis was confirmed by DNA sequencing. The method was linear over a concentration range of 0.03-200ng/mL with a mean recovery rate of 98.6%. The intra- and inter-day variation coefficients assessed at two concentrations were below 15%. Limits of quantification (LOQ) and detection (LOD) were 0.03ng/mL and 0.01ng/mL, respectively. Receiver operating characteristic (ROC) analysis estimated that the area under curve was 0.997 implying a significant discriminatory power to identify subjects with NPC. Nevertheless, 13 NPC patients and 29 control subjects confirmed by sequencing showed false negative or positive results, respectively. Two patients with cerebrotendinous xanthomatosis showed a 5-10-fold increase in C-triol levels. We developed a quick and sensitive GC-MS method for determination of C-triol, which may serve as a simple and inexpensive diagnostic tool aiding NPC diagnosis in a routine hospital laboratory. As C-triol elevation is not limited to NPC, the NPC diagnosis has to be confirmed by DNA sequencing. Copyright © 2016 Elsevier Ltd. All rights reserved.
Garrison, Arthur W; Avants, Jimmy K; Miller, Rebecca D
2011-08-01
Propiconazole is a chiral fungicide used in agriculture for control of many fungal diseases on a variety of crops. This use provides opportunities for pollution of soil and, subsequently, groundwater. The rate of loss of propiconazole from the water phase of two different soil-water slurries spiked with the fungicide at 50 mg/L was followed under aerobic conditions over five months; the t(1/2) was 45 and 51 days for the two soil slurries. To accurately assess environmental and human risk, it is necessary to analyze the separate stereoisomers of chiral pollutants, because it is known that for most such pollutants, both biotransformation and toxicity are likely to be stereoselective. Micellar electrokinetic chromatography (MEKC), the mode of capillary electrophoresis used for analysis of neutral chemicals, was used for analysis of the four propiconazole stereoisomers with time in the water phase of the slurries. MEKC resulted in baseline separation of all stereoisomers, while GC-MS using a chiral column gave only partial separation. The four stereoisomers of propiconazole were lost from the aqueous phase of the slurries at experimentally equivalent rates, i.e., there was very little, if any, stereoselectivity. No loss of propiconazole was observed from the autoclaved controls of either soil, indicating that the loss from active samples was most likely caused by aerobic biotansformation, with a possible contribution by sorption to the non-autoclaved active soils. MEKC is a powerful tool for separation of stereoisomers and can be used to study the fate and transformation kinetics of chiral pesticides in water and soil.
Sverko, Ed
2006-01-01
Analytical methods for the analysis of polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs) are widely available and are the result of a vast amount of environmental analytical method development and research on persistent organic pollutants (POPs) over the past 30–40 years. This review summarizes procedures and examines new approaches for extraction, isolation, identification and quantification of individual congeners/isomers of the PCBs and OCPs. Critical to the successful application of this methodology is the collection, preparation, and storage of samples, as well as specific quality control and reporting criteria, and therefore these are also discussed. With the signing of the Stockholm convention on POPs and the development of global monitoring programs, there is an increased need for laboratories in developing countries to determine PCBs and OCPs. Thus, while this review attempts to summarize the current best practices for analysis of PCBs and OCPs, a major focus is the need for low-cost methods that can be easily implemented in developing countries. A “performance based” process is described whereby individual laboratories can adapt methods best suited to their situations. Access to modern capillary gas chromatography (GC) equipment with either electron capture or low-resolution mass spectrometry (MS) detection to separate and quantify OCP/PCBs is essential. However, screening of samples, especially in areas of known use of OCPs or PCBs, could be accomplished with bioanalytical methods such as specific commercially available enzyme-linked immunoabsorbent assays and thus this topic is also reviewed. New analytical techniques such two-dimensional GC (2D-GC) and “fast GC” using GC–ECD may be well-suited for broader use in routine PCB/OCP analysis in the near future given their relatively low costs and ability to provide high-resolution separations of PCB/OCPs. Procedures with low environmental impact (SPME, microscale, low solvent use, etc.) are increasingly being used and may be particularly suited to developing countries. Electronic supplementary material Supplementary material is available in the online version of this article at http://dx.doi.org/10.1007/s00216-006-0765-y and is accessible for authorized users. PMID:17047943
Chaib, Faiza; Allali, Hocine; Bennaceur, Malika; Flamini, Guido
2017-08-01
In recent years, antimicrobial activities of essential oils have been intensively explored, mainly in researching and developing new antimicrobial agents to overcome microbial resistance. The present study investigates the chemical composition and antimicrobial activities of essential oils obtained from two Asteraceae: Asteriscus graveolens (Forssk.) Less. and Pulicaria incisa (Lam.) DC. Chemical analysis was performed using a combination of capillary GC-FID and GC/MS analytical techniques. The major component of Asteriscus graveolens were cis-chrysanthenyl acetate (31.1%), myrtenyl acetate (15.1%), and kessane (11.5%), while for Pulicaria incisa the main components were chrysanthenone (45.3%) and 2,6-dimethylphenol (12.6%). The oils obtained from the aerial parts were tested against sixteen microbial strains by agar well diffusion technique and dilution methods and showed minimum inhibitory concentrations (MIC) in the range of 19 - 1250 μg/ml. A good antibacterial activity against a common nosocomial pathogen, Acinetobacter baumanniiATCC 19606 was observed, especially from Pulicaria incisa essential oil, with a MIC value up to 19 μg/ml. These results give significant information about the pharmacological activity of these essential oils, which suggest their benefits to human health, having the potential to be used for medical purposes. © 2017 Wiley-VHCA AG, Zurich, Switzerland.
A Study on the Reliability of an On-Site Oral Fluid Drug Test in a Recreational Context
Gentili, Stefano; Tittarelli, Roberta; Mannocchi, Giulio
2016-01-01
The reliability of DrugWipe 5A on site test for principal drugs of abuse (cannabis, amphetamines, cocaine, and opiates) detection in oral fluid was assessed by comparing the on-site results with headspace solid-phase microextraction (HS-SPME) gas chromatography-mass spectrometry (GC-MS) analysis on samples extracted by the device collection pad. Oral fluid samples were collected at recreational settings (e.g., discos, pubs, and music bars) of Rome metropolitan area. Eighty-three club goers underwent the on-site drug screening test with one device. Independently from the result obtained, a second device was used just to collect another oral fluid sample subsequently extracted and analyzed in the laboratory following HS-SPME procedure, gas chromatographic separation by a capillary column, and MS detection by electron impact ionization. DrugWipe 5A on-site test showed 54 samples (65.1%) positive to one or more drugs of abuse, whereas 75 samples (90.4%) tested positive for one or more substances following GC-MS assay. Comparing the obtained results, the device showed sensitivity, specificity, and accuracy around 80% for amphetamines class. Sensitivity (67 and 50%) was obtained for cocaine and opiates, while both sensitivity and accuracy were unsuccessful (29 and 53%, resp.) for cannabis, underlying the limitation of the device for this latter drug class. PMID:27610266
DOE Office of Scientific and Technical Information (OSTI.GOV)
Creasy, W.R.; Brickhouse, M.D.; Morrisse, K.M.
1999-07-01
Decontamination waste from chemical weapons (CW) agents has been stored in ton containers on Johnston Atoll since 1971. The waste was recently sampled and analyzed to determine its chemical composition in preparation for future cleanups. Due to the range of products and analytical requirements, multiple chromatographic and spectroscopic methods were necessary, including gas chromatography/mass spectrometry (GC/MS), gas chromatography/atomic emission detection (GC/AED), liquid chromatography/mass spectrometry (LC/MS), capillary electrophoresis (CE), and nuclear magnetic resonance spectroscopy (NMR). The samples were screened for residual agents. No residual sarin (GB) or VX was found to detection limits of 20 ng/mL, but 3% of the samplesmore » contained residual sulfur mustard (HD) at < 140 ng/mL. Decontamination products of agents were identified. The majority (74%) of the ton containers were documented correctly, in that the observed decontamination products were in agreement with the labeled agent type, but for a number of the containers, the contents were not in agreement with the labels. In addition, arsenic compounds that are decontamination products of the agent lewisite (L) were observed in a few ton containers, suggesting that lewisite was originally present but not documented. This study was a prototype to demonstrate the level of effort required to characterize old bulk CW-related waste.« less
Li, Yanming; Hu, Yongjie; Liu, Jinhua; Guo, Yuliang; Wang, Guiqin
2011-04-01
A gas chromatography-mass spectrometry (GC-MS) method has been developed for the determination of dibutyltin (DBT), tributyltin (TBT) and triphenyltin (TPhT) in textile auxiliaries. The sample was first extracted with n-hexane in acetate buffer solution (pH 4.0) under ultrasonication (for hydrophobic sample) or oscillation extraction (for hydrophilic sample) and then derivatized with sodium tetraethylborate in tetrahydrofuran. The derivative was determined by GC-MS in selected ion monitoring (SIM) mode. The separation and quantification were achieved using a Rxi-5 ms silica capillary column (30 m x 0.25 mm x 0.25 microm). The linear ranges were 0.1-8.0 mg/L for both DBT and TBT, and 0.1-4.0 mg/L for TPhT. There were good linear relationships between the peak area and concentration in the linear ranges and the correlation coefficients (r2) were 0.9994-0.9998. The detection limits (LOD) were from 0.003 mg/L to 0.005 mg/L. The average recoveries of these organotin compounds at the three spiked levels of 4.0, 10.0 and 40.0 mg/kg were 92.6%-108.0% with the relative standard deviations (RSDs) of 2.5%-10.2%. The method is simple and accurate for simultaneous analysis of the DBT, TBT and TPhT in textile auxiliaries.
INVESTIGATION OF CE/LIF AS A TOOL IN THE ...
The investigation of emerging contaminant issues is a proactive effort in environmental analysis. As a part of this effort, sewage effluent is of current analytical interest because of the presence of pharmaceuticals and their metabolites and personal care products The environmental impact of these components is still under investigation but their constant perfusion into receiving waters and their potential effect on biota is of concern. This paper examines a tool for the characterization of sewage effluent using capillary electrophoresis/laser-induced fluorescence (CE/LIF) with a frequency-doubled laser operated in the ultraviolet (UV). Fluorescent acidic analytes are targeted because they present special problems for techniques such as gas chromatography/mass spectrometry (GC/MS) but are readily accessible to CE/LIF. As an example of the application of this tool, salicylic acid is determined near the 100 ng/L level in sewage effluent. Salicylic acid is a metabolite of various analgesics Relatively stable in the environment, it is a common contaminant of municipal sewage systems. Salicylic acid was recovered from freshly collected samples of the effluent by liquid-liquid extraction as part of a broad characterization effort. Confirmation of identity was by electron ionization GC/MS after conversion of the salicylic acid to the methyl ester by means of trimethylsilyidiazomethane CE/LIF in the UV has revealed more than 50 individual peaks in the extract and a bac
Jillani, Shehzada Muhammad Sajid; Alhooshani, Khalid
2018-03-30
Sol-gel urea functionalized-[bis(hydroxyethyl)amine] terminated polydimethylsiloxane coating was developed for capillary microextraction-high performance liquid chromatographic analysis from aqueous samples. A fused silica capillary is coated from the inside with surface bonded coating material and is created through in-situ sol-gel reaction. The urea-functionalized coating was immobilized to the inner surface of the capillary by the condensation reaction of silanol groups of capillary and sol-solution. The characterization of the coating material was successfully done by using X-ray photoelectron spectroscopy, thermogravimetric analysis, field emission scanning electron microscope, and energy dispersive X-ray spectrometer. To make a setup of online capillary microextraction-high performance liquid chromatography, the urea functionalized capillary was installed in the HPLC manual injection port. The analytes of interest were pre-concentrated in the coated sampling loop, desorbed by the mobile phase, chromatographically separated on C-18 column, and analyzed by UV detector. Sol-gel coated capillaries were used for online extraction and high-performance liquid chromatographic analysis of phenols, ketones, aldehydes, and polyaromatic hydrocarbons. This newly developed coating showed excellent extraction for a variety of analytes ranging from highly polar to non-polar in nature. The analysis using sol-gel coating showed excellent overall sensitivity in terms of lower detection limits (S/N = 3) for the analytes (0.10 ng mL -1 -14.29 ng mL -1 ) with acceptable reproducibility that is less than 12.0%RSD (n = 3). Moreover, the capillary to capillary reproducibility of the analysis was also tested by changing the capillary of the same size. This provided excellent%RSD of less than 10.0% (n = 3). Copyright © 2018 Elsevier B.V. All rights reserved.
Geochemical typing of crude oils from the Gulf of Thailand and the Natuna Sea
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shiefelbein, C.; Haven, H.L.T.
The geochemical characteristics of approximately thirty oils from the Gulf of Thailand and Natuna Sea have been measured, viz., sulfur, vanadium and nickel content, density, [sup 13]C isotopes of the isolated aliphatic and aromatic hydrocarbon fractions, capillary gas chromatography of the whole oil, and gas chromatography-mass spectrometry (GC-MS). The GC-MS analysis included the classical monitoring of specific ions (SIM mode) as well as sophisticated multiple reaction monitoring (MRM) measurements (MRM mode). These latter analyses are of key importance for the detection of 24-propylsteranes, a prerequisite for the discrimination between lacustrine/deltaic oils vs. marine crude oils. Classification of the different typesmore » of oil families encountered in this region was based on visual inspection of the data, supported by multivariate statistical analysis. In the Gulf of Thailand, which includes oils from the Pattani trough and the northern part of the Malay basin, essentially three different types are recognized, generated by lacustrine, resinous, and carbonate source rocks. The situation encountered in the Natuna sea, including oils from the southern part of the Malay basin (Indonesia), the Penyu basin, and the west and east Natuna basins is almost similar to the same suite of different oil types. Although the geochemical characteristics of the resinous-derived oils are more or less similar in all basins, the lacustrine-derived oils exhibit large variations especially expressed in their isotopic signature. Interestingly, the carbonate-sourced oils from the east Natuna basin show characteristics that resemble those of the main oil family found offshore northwest Palawan.« less
Gas chromatographic determination of yohimbine in commercial yohimbe products.
Betz, J M; White, K D; der Marderosian, A H
1995-01-01
The bark of Pausinystalia yohimbe [K. Schumann] Pierre (Rubiaceae), long valued as an aphrodisiac in West Africa, recently has been promoted in the United States as a dietary supplement alternative to anabolic steroids for enhancement of athletic performance. As the number of yohimbe products on the retail market increases, concerns about their safety are raised because of the reported toxicity of yohimbine (the major alkaloid of the plant). Although plant materials are usually identified microscopically, we were unable to identify them in many of the products, because as their labels indicated, the products were mixtures of various botanicals or were bark extracts and contained little or no plant material. A method for extraction and capillary gas chromatographic (GC) separation of the alkaloids of P. yohimbe was, therefore, developed and used to analyze a number of commercial yohimbe products. The method involved solvent extraction and partitioning in chloroform-water followed by separation on a methyl silicone capillary GC column (N-P detection). Comparisons of chromatograms of extracts of authentic bark with those of commercial products indicated that, although many products contained measurable quantities of the alkaloid yohimbine, they were largely devoid of the other alkaloids previously reported in this species. Concentrations of yohimbine in the commercial products ranged from < 0.1 to 489 ppm, compared with 7089 ppm in the authentic material. Authentic bark has been reported to contain up to 6% total alkaloids, 10-15% of which are yohimbine. The possible presence of undeclared diluents in the products was indicated by peaks in product chromatograms but not in those of authentic bark.
Fitz, Brian D; Mannion, Brandyn C; To, Khang; Hoac, Trinh; Synovec, Robert E
2015-05-01
Low thermal mass gas chromatography (LTM-GC) was evaluated for rapid, high peak capacity separations with three injection methods: liquid, headspace solid phase micro-extraction (HS-SPME), and direct vapor. An Agilent LTM equipped with a short microbore capillary column was operated at a column heating rate of 250 °C/min to produce a 60s separation. Two sets of experiments were conducted in parallel to characterize the instrumental platform. First, the three injection methods were performed in conjunction with in-house built high-speed cryo-focusing injection (HSCFI) to cryogenically trap and re-inject the analytes onto the LTM-GC column in a narrower band. Next, the three injection methods were performed natively with LTM-GC. Using HSCFI, the peak capacity of a separation of 50 nl of a 73 component liquid test mixture was 270, which was 23% higher than without HSCFI. Similar peak capacity gains were obtained when using the HSCFI with HS-SPME (25%), and even greater with vapor injection (56%). For the 100 μl vapor sample injected without HSCFI, the preconcentration factor, defined as the ratio of the maximum concentration of the detected analyte peak relative to the analyte concentration injected with the syringe, was determined to be 11 for the earliest eluting peak (most volatile analyte). In contrast, the preconcentration factor for the earliest eluting peak using HSCFI was 103. Therefore, LTM-GC is demonstrated to natively provide in situ analyte trapping, although not to as great an extent as with HSCFI. We also report the use of LTM-GC applied with time-of-flight mass spectrometry (TOFMS) detection for rapid, high peak capacity separations from SPME sampled banana peel headspace. Copyright © 2015 Elsevier B.V. All rights reserved.
Paoloni, Angela; Alunni, Sabrina; Pelliccia, Alessandro; Pecorelli, Ivan
2016-01-01
A simple and straightforward method for simultaneous determination of residues of 13 pesticides in honey samples (acrinathrin, bifenthrin, bromopropylate, cyhalothrin-lambda, cypermethrin, chlorfenvinphos, chlorpyrifos, coumaphos, deltamethrin, fluvalinate-tau, malathion, permethrin and tetradifon) from different pesticide classes has been developed and validated. The analytical method provides dissolution of honey in water and an extraction of pesticide residues by n-Hexane followed by clean-up on a Florisil SPE column. The extract was evaporated and taken up by a solution of an injection internal standard (I-IS), ethion, and finally analyzed by capillary gas chromatography with electron capture detection (GC-µECD). Identification for qualitative purpose was conducted by gas chromatography with triple quadrupole mass spectrometer (GC-MS/MS). A matrix-matched calibration curve was performed for quantitative purposes by plotting the area ratio (analyte/I-IS) against concentration using a GC-µECD instrument. According to document No. SANCO/12571/2013, the method was validated by testing the following parameters: linearity, matrix effect, specificity, precision, trueness (bias) and measurement uncertainty. The analytical process was validated analyzing blank honey samples spiked at levels equal to and greater than 0.010 mg/kg (limit of quantification). All parameters were satisfactorily compared with the values established by document No. SANCO/12571/2013. The analytical performance was verified by participating in eight multi-residue proficiency tests organized by BIPEA, obtaining satisfactory z-scores in all 70 determinations. Measurement uncertainty was estimated according to the top-down approaches described in Appendix C of the SANCO document using the within-laboratory reproducibility relative standard deviation combined with laboratory bias using the proficiency test data.
Hsieh, Cheng-Huan; Meher, Anil Kumar; Chen, Yu-Chie
2013-01-01
Contactless atmospheric pressure ionization (C-API) method has been recently developed for mass spectrometric analysis. A tapered capillary is used as both the sampling tube and spray emitter in C-API. No electric contact is required on the capillary tip during C-API mass spectrometric analysis. The simple design of the ionization method enables the automation of the C-API sampling system. In this study, we propose an automatic C-API sampling system consisting of a capillary (∼1 cm), an aluminium sample holder, and a movable XY stage for the mass spectrometric analysis of organics and biomolecules. The aluminium sample holder is controlled by the movable XY stage. The outlet of the C-API capillary is placed in front of the orifice of a mass spectrometer, whereas the sample well on the sample holder is moved underneath the capillary inlet. The sample droplet on the well can be readily infused into the C-API capillary through capillary action. When the sample solution reaches the capillary outlet, the sample spray is readily formed in the proximity of the mass spectrometer applied with a high electric field. The gas phase ions generated from the spray can be readily monitored by the mass spectrometer. We demonstrate that six samples can be analyzed in sequence within 3.5 min using this automatic C-API MS setup. Furthermore, the well containing the rinsing solvent is alternately arranged between the sample wells. Therefore, the C-API capillary could be readily flushed between runs. No carryover problems are observed during the analyses. The sample volume required for the C-API MS analysis is minimal, with less than 1 nL of the sample solution being sufficient for analysis. The feasibility of using this setup for quantitative analysis is also demonstrated.
Distribution of the most common polymorphisms in TYMS gene in Slavic population of central Europe.
Pastorakova, A; Chandogova, D; Chandoga, J; Luha, J; Bohmer, D; Malova, J; Braxatorisova, T; Juhosova, M; Reznakova, S; Petrovic, R
2017-01-01
Thymidylate synthetase (TS) plays a critical role in the de novo synthesis of dTMP inside the cell. Therefore, TS is a suitable target for cytotoxic drugs such as fluoropyrimidines. Drug efficacy and toxicity depend on the intracellular level of TS, which is significantly influenced by the polymorphisms in the 5'UTR (TSER - rs45445694, TSER*3G>C - rs2853542) and 3'UTR (1494del TTAAAG - rs151264360) of TYMS gene. Polymorphic variants of TYMS gene affect TS activity via gene expression and transcript stability. Patients who undergo fluoropyrimidine therapy may benefit from genetic testing prior to the administration of chemotherapy. At the 5' terminus of TYMS, there is a polymorphic region represented by a variable number of 28bp long tandem repeats (2-9 tandems) with the G or C nucleotide variant (SNP G>C). The 3'end of TYMS gene may decrease the stability of mRNA in the case of 6 base deletion (1494del6, D). In our study, we have focused on testing of TYMS gene polymorphisms, determination of TYMS variant frequencies in Western Slavic population and comparison of Slovak population with other populations.We performed identification of 5'UTR (rs45445694 - TSER*2 or TSER*3; rs2853542 - TSER*3G>C; TSER*3+ins6) and 3'UTR (rs151264360/1494del6/D) polymorphic regions of TYMS gene among 96 volunteers by PCR-RFLP and fragment analysis. Slovak frequencies of selected polymorphisms were established as follows: the frequency of TSER*2, TSER*3, TSER*3G>C, 1494del6/D and I to be 41%, 59%, 34%, 37.5% and 62.5% respectively. The high resolution of the capillary electrophoresis technique allowed among TSER*3 group identification of a subgroup of four individuals with rare 6bp insertion in 3R allele, id est 2.1% TSER*3+ins6 allele frequency. In our study, we have revealed individuals with rare G>C substitution in the first 28bp tandem repeat of TSER*2 promoter enhancer region (rs183205964) as well, the overall frequency of this polymorphic allele in Slovak population was 2.1%. Our results proved that Slovak population is in Hardy-Weinberg equilibrium and proportion of TYMS polymorphisms is in accordance with other published data.
Sivasothy, Yasodha; Nagoor, Noor Hasima; Jamil, Natasha; Awang, Khalijah
2014-01-01
The essential oils obtained by hydrodistillation of the unripe and ripe fruits of Alpinia mutica Roxb. and Alpinia latilabris Ridl. were analysed by capillary GC and GC-MS. The oils were principally monoterpenic in nature. The unripe and ripe fruit oils of A. mutica were characterized by camphor (21.0% and 15.8%), camphene (16.6% and 10.2%), β-pinene (8.6% and 13.5%), and trans,trans-farnesol (8.0% and 11.2%), respectively. The oils of the unripe and ripe fruits were moderately active against Staphylococcus aureus, Bacillus subtilis, Trichophyton mentagrophytes, and Trichophyton rubrum. 1,8-Cineole (34.2% and 35.9%) and β-pinene (20.2% and 19.0%) were the two most abundant components in the unripe and ripe fruit oils of A. latilabris. The oil of the unripe fruits elicits moderate activity against Staphylococcus aureus and Trichophyton mentagrophytes while Candida glabrata was moderately sensitive to the oil of the ripe fruits. PMID:24987733
Ibrahim, Halijah; Sivasothy, Yasodha; Syamsir, Devi Rosmy; Nagoor, Noor Hasima; Jamil, Natasha; Awang, Khalijah
2014-01-01
The essential oils obtained by hydrodistillation of the unripe and ripe fruits of Alpinia mutica Roxb. and Alpinia latilabris Ridl. were analysed by capillary GC and GC-MS. The oils were principally monoterpenic in nature. The unripe and ripe fruit oils of A. mutica were characterized by camphor (21.0% and 15.8%), camphene (16.6% and 10.2%), β-pinene (8.6% and 13.5%), and trans,trans-farnesol (8.0% and 11.2%), respectively. The oils of the unripe and ripe fruits were moderately active against Staphylococcus aureus, Bacillus subtilis, Trichophyton mentagrophytes, and Trichophyton rubrum. 1,8-Cineole (34.2% and 35.9%) and β-pinene (20.2% and 19.0%) were the two most abundant components in the unripe and ripe fruit oils of A. latilabris. The oil of the unripe fruits elicits moderate activity against Staphylococcus aureus and Trichophyton mentagrophytes while Candida glabrata was moderately sensitive to the oil of the ripe fruits.
Essential oil constituents and antimicrobial activity of Pycnocycla bashagardiana Mozaff. from Iran.
Alizadeh, Ardalan; Abdollahzadeh, Hamid
2017-09-01
Pycnocycla bashagardiana is a rare endemic and endangered species that has been used in folkloric medicine in Southern Iran. This study aimed to evaluate the essential oil constituents and antimicrobial activity of wild and cultivated p. bashagardiana. The aerial parts of wild and cultivated plants were collected from two provinces of Iran. The essential oil was isolated by hydrodistillation and analyzed by a combination of capillary GC and GC-MS. The main components in wild plants were myristicin (39.12%), (E)-β-ocimene (21.97%), sabinene (15.0%) and cis-iso-miristicin (2.67%) and in cultivated plants, (E)-β-ocimene (55.40%), myristicin (18.27%), (Z)-β-ocimene (12.47%) and cis-iso-miristicin (2.94%) were the main constituents in essential oil. The in vitro antimicrobial activity of the essential oil of P. bashagardiana were studied against Staphylococcus aureus, Staphylococcus epidermidis, Escherichia coli and Candida albicans for the first time. The results showed that the oil exhibited strong antimicrobial activity against all the tested pathogens.
Thaxton-Weissenfluh, Amber; Belal, Tarek S; DeRuiter, Jack; Smith, Forrest; Abiedalla, Younis; Neel, Logan; Abdel-Hay, Karim M; Clark, C Randall
2018-06-16
The indole ring regioisomeric methoxy-1-n-pentyl-3-(1-naphthoyl)-indoles represent indole ring-substituted analogs of the synthetic cannabinoid JWH-018. The electron ionization mass spectra show equivalent regioisomeric major fragments resulting from cleavage of the groups attached to the central indole nucleus. The characteristic (M-17)+ fragment ion at m/z 354 resulting from the loss of OH group is significant in the mass spectra of all four compounds. Fragmentation of the naphthoyl and/or pentyl groups yields the cations at m/z 314, 300, 244 and 216. The vapor-phase infrared spectra provide a number of characteristic absorption bands to identify the individual isomers. Gas chromatographic separations on a capillary column containing a film of trifluoropropylmethyl polysiloxane (Rtx-200) provided excellent resolution of these compounds, their precursor indoles and intermediate pentylindoles. The elution order appears related to the degree of crowding of indole ring substituents.
Yang, Xiaohong; Han, Ying; Qi, Meiling; Chen, Chuanfeng
2016-05-06
Unique structures and molecular recognition ability endow iptycene derivatives with great potential as stationary phases in chromatography, which, however, has not been explored yet. Herein, we report the first example of utilizing a pentiptycene quinone (PQ) for gas chromatographic (GC) separations. Remarkably, the statically coated capillary column with the stationary phase achieved extremely high column efficiency of 4800 plates/m. It exhibited preferential retention and high resolving capability for H-bonding and aromatic analytes and positional isomers, showing advantages over the ordinary polysiloxane phase. Moreover, the fabricated iptycene column showed excellent separation repeatability with RSD values of 0.02-0.06% for intra-day, 0.20-0.35% for inter-day and 3.1-5.5% for between-column, respectively. In conclusion, iptycene derivatives as a new class of stationary phases show promising future for their use in GC separations. Copyright © 2016 Elsevier B.V. All rights reserved.
Paper Capillary Enables Effective Sampling for Microfluidic Paper Analytical Devices.
Shangguan, Jin-Wen; Liu, Yu; Wang, Sha; Hou, Yun-Xuan; Xu, Bi-Yi; Xu, Jing-Juan; Chen, Hong-Yuan
2018-06-06
Paper capillary is introduced to enable effective sampling on microfluidic paper analytical devices. By coupling mac-roscale capillary force of paper capillary and microscale capillary forces of native paper, fluid transport can be flexibly tailored with proper design. Subsequently, a hybrid-fluid-mode paper capillary device was proposed, which enables fast and reliable sampling in an arrayed form, with less surface adsorption and bias for different components. The resulting device thus well supports high throughput, quantitative, and repeatable assays all by hands operation. With all these merits, multiplex analysis of ions, proteins, and microbe have all been realized on this platform, which has paved the way to level-up analysis on μPADs.
The paper describes the application of capillary supercritical fluid chromatography (SFC) to the analysis of a middle distillate fuel. Small diameter (50 micrometer i.d.) fused silica capillary columns coated with crosslinked 50% phenyl polymethylsiloxane provided high separation...
Celik-Ozenci, Ciler; Akkoyunlu, Gokhan; Kayisli, Umit Ali; Arici, Aydin; Demir, Ramazan
2003-11-01
There is increasing evidence that in many species angiogenic factors, such as vascular endothelial growth factor (VEGF) and basic fibroblast growth factor (bFGF), may have important roles in folliculogenesis. The aim of this study is to determine the localization of VEGF and its receptors, Flt-1 and KDR, and bFGF expression in the rat ovary and to evaluate their distributions throughout the different follicular stages. Out of 20 virginal female rats, 10 were studied during the natural ovarian cycle without any ovulation induction. The other 10 were superovulated and their ovaries were studied by western analysis and immunohistochemistry. Granulosa cells (GC) and oocytes of primordial follicles were negative for VEGF. In early primary follicles, VEGF was present in the oocyte but its immunoreactivity was weak, while newly developing zona pellucida (ZP) of primary follicles was negative for VEGF. Subsequently, with the commencement of antral spaces between GC of the secondary follicle, ZP of some secondary follicles became strongly positive for VEGF, forming a continuous ring around the oocyte. In preovulatory mature follicles granulosa and theca interna (TI) cells showed a weak immunoreactivity for VEGF. Western blot analyses have also demonstrated that VEGF, a 26-kDa protein, was present in follicles. Moreover, in ovulated cumulus-oocyte complex we observed a halo-like immunoreactivity of VEGF around the fully mature oocyte. The immunoreactivity for Flt-1 and KDR receptors in growing follicles was mostly limited to GC and TI cells. Anti-bFGF did not exhibit any immunoreactivity in ZP of follicles at any stage. Its expression was weak in GC of the follicles at different stages, whereas, it could be localized to some extent in the blood capillaries of TI of antral follicles and in blood vessels localized in the stroma. Interestingly, VEGF immunoreactivity in the ZP of some secondary follicles is very striking. Accordingly, the possibility that VEGF may be an important regulatory molecule for the dominant follicle selection or atresia should be considered.
Enhancing separation in short-capillary electrophoresis via pressure-driven backflow.
Tian, Miaomiao; Wang, Yujia; Mohamed, Amara Camara; Guo, Liping; Yang, Li
2015-07-01
We present a novel easy-to-operate and efficient method to improve the separation efficiency in short-capillary electrophoresis by introducing steady backflow to counterbalance electro-osmotic flow without the use of any external pressure. The backflow was easily generated by tapering the capillary end, which was achieved by heating a straight capillary and stretching it with a constant force. We investigated the net fluidic transport rate under different tip lengths and separation voltages. Good run-to-run repeatability and capillary-to-capillary reproducibility of the present method were obtained with RSD less than 1.5%, indicating the stability of the fluid transport rate in the tapered capillary, which ensures the quantification and repeatability of capillary zone electrophoresis (CZE) analysis. Enhanced separation of the tapered short capillary electrophoresis was demonstrated by CZE analyzing amino acids and positional isomers. Baseline separations were achieved in less than 60 s using a tapered capillary with the effective length of 5 cm, while no separation was achieved using a normal capillary without a tapered tip. The present study provides a promising method to use pressure-driven backflow to enhance separation efficiency in short-capillary electrophoresis, which would be of potential value in a wide application for fast analysis of complex samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Cerebral capillary velocimetry based on temporal OCT speckle contrast.
Choi, Woo June; Li, Yuandong; Qin, Wan; Wang, Ruikang K
2016-12-01
We propose a new optical coherence tomography (OCT) based method to measure red blood cell (RBC) velocities of single capillaries in the cortex of rodent brain. This OCT capillary velocimetry exploits quantitative laser speckle contrast analysis to estimate speckle decorrelation rate from the measured temporal OCT speckle signals, which is related to microcirculatory flow velocity. We hypothesize that OCT signal due to sub-surface capillary flow can be treated as the speckle signal in the single scattering regime and thus its time scale of speckle fluctuations can be subjected to single scattering laser speckle contrast analysis to derive characteristic decorrelation time. To validate this hypothesis, OCT measurements are conducted on a single capillary flow phantom operating at preset velocities, in which M-mode B-frames are acquired using a high-speed OCT system. Analysis is then performed on the time-varying OCT signals extracted at the capillary flow, exhibiting a typical inverse relationship between the estimated decorrelation time and absolute RBC velocity, which is then used to deduce the capillary velocities. We apply the method to in vivo measurements of mouse brain, demonstrating that the proposed approach provides additional useful information in the quantitative assessment of capillary hemodynamics, complementary to that of OCT angiography.
Arakawa, H; Neault, J F; Tajmir-Riahi, H A
2001-01-01
Ag(I) is a strong nucleic acids binder and forms several complexes with DNA such as types I, II, and III. However, the details of the binding mode of silver(I) in the Ag-polynucleotides remains unknown. Therefore, it was of interest to examine the binding of Ag(I) with calf-thymus DNA and bakers yeast RNA in aqueous solutions at pH 7.1-6.6 with constant concentration of DNA or RNA and various concentrations of Ag(I). Fourier transform infrared spectroscopy and capillary electrophoresis were used to analyze the Ag(I) binding mode, the binding constant, and the polynucleotides' structural changes in the Ag-DNA and Ag-RNA complexes. The spectroscopic results showed that in the type I complex formed with DNA, Ag(I) binds to guanine N7 at low cation concentration (r = 1/80) and adenine N7 site at higher concentrations (r = 1/20 to 1/10), but not to the backbone phosphate group. At r = 1/2, type II complexes formed with DNA in which Ag(I) binds to the G-C and A-T base pairs. On the other hand, Ag(I) binds to the guanine N7 atom but not to the adenine and the backbone phosphate group in the Ag-RNA complexes. Although a minor alteration of the sugar-phosphate geometry was observed, DNA remained in the B-family structure, whereas RNA retained its A conformation. Scatchard analysis following capillary electrophoresis showed two binding sites for the Ag-DNA complexes with K(1) = 8.3 x 10(4) M(-1) for the guanine and K(2) = 1.5 x 10(4) M(-1) for the adenine bases. On the other hand, Ag-RNA adducts showed one binding site with K = 1.5 x 10(5) M(-1) for the guanine bases. PMID:11509371
Seyyal, Emre; Malik, Abdul
2017-04-29
Principles of sol-gel chemistry were utilized to create silica- and germania-based dual-ligand surface-bonded sol-gel coatings providing enhanced performance in capillary microextraction (CME) through a combination of ligand superhydrophobicity and π-π interaction. These organic-inorganic hybrid coatings were prepared using sol-gel precursors with bonded perfluorododecyl (PF-C 12 ) and phenethyl (PhE) ligands. Here, the ability of the PF-C 12 ligand to provide enhanced hydrophobic interaction was advantageously combined with π-π interaction capability of the PhE moiety to attain the desired sorbent performance in CME. The effect of the inorganic sorbent component on microextraction performance of was explored by comparing microextraction characteristics of silica- and germania-based sol-gel sorbents. The germania-based dual-ligand sol-gel sorbent demonstrated superior CME performance compared to its silica-based counterpart. Thermogravimetric analysis (TGA) of the created silica- and germania-based dual-ligand sol-gel sorbents suggested higher carbon loading on the germania-based sorbent. This might be indicative of more effective condensation of the organic ligand-bearing sol-gel-active chemical species to the germania-based sol-gel network (than to its silica-based counterpart) evolving in the sol solution. The type and concentration of the organic ligands were varied in the sol-gel sorbents to fine-tune extraction selectivity toward different classes of analytes. Specific extraction (SE) values were used for an objective comparison of the prepared sol-gel CME sorbents. The sorbents with higher content of PF-C 12 showed remarkable affinity for aliphatic hydrocarbons. Compared to their single-ligand sol-gel counterparts, the dual-ligand sol-gel coatings demonstrated significantly superior CME performance in the extraction of alkylbenzenes, providing up to ∼65.0% higher SE values. The prepared sol-gel CME coatings provided low ng L -1 limit of detections (LOD) (4.2-26.3 ng L -1 ) for environmentally important analytes including polycyclic aromatic hydrocarbons, ketones and aliphatic hydrocarbons. In CME-GC experiments (n = 5), the capillary-to-capillary RSD value was ∼2.1%; such a low RSD value is indicative of excellent reproducibility of the sol-gel method used for the preparation of these CME coatings. The dual-ligand sol-gel coating provided stable performance in capillary microextraction of analytes from saline samples. Copyright © 2017 Elsevier B.V. All rights reserved.
Shen, Shixuan; Chen, Xiaohui; Li, Hao; Sun, Liping; Yuan, Yuan
2018-01-01
Background: The promoter methylation of MLH1 gene and gastric cancer (GC)has been investigated previously. To get a more credible conclusion, we performed a systematic review and meta and bioinformatic analysis to clarify the role of MLH1 methylation in the prediction and prognosis of GC. Methods: Eligible studies were targeted after searching the PubMed, Web of Science, Embase, BIOSIS, CNKI and Wanfang Data to collect the information of MLH1 methylation and GC. The link strength between the two was estimated by odds ratio with its 95% confidence interval. The Newcastle-Ottawa scale was used for quantity assessment . Subgroup and sensitivity analysis were conducted to explore sources of heterogeneity. The Gene Expression Omnibus (GEO) and The Cancer Genome Atlas (TCGA) were employed for bioinformatics analysis on the correlation between MLH1 methylation and GC risk, clinicopathological behavior as well as prognosis. Results: 2365 GC and 1563 controls were included in the meta-analysis. The pooled OR of MLH1 methylation in GC was 4.895 (95% CI: 3.149-7.611, P<0.001), which considerably associated with increased GC risk. No significant difference was found in relation to Lauren classification, tumor invasion, lymph node/distant metastasis and tumor stage in GC. Analysis based on GEO and TCGA showed that high MLH1 methylation enhanced GC risk but might not related with GC clinicopathological features and prognosis. Conclusion: MLH1 methylation is an alive biomarker for the prediction of GC and it might not affect GC behavior. Further study could be conducted to verify the impact of MLH1 methylation on GC prognosis.
Shen, Shixuan; Chen, Xiaohui; Li, Hao; Sun, Liping; Yuan, Yuan
2018-01-01
Background: The promoter methylation of MLH1 gene and gastric cancer (GC)has been investigated previously. To get a more credible conclusion, we performed a systematic review and meta and bioinformatic analysis to clarify the role of MLH1 methylation in the prediction and prognosis of GC. Methods: Eligible studies were targeted after searching the PubMed, Web of Science, Embase, BIOSIS, CNKI and Wanfang Data to collect the information of MLH1 methylation and GC. The link strength between the two was estimated by odds ratio with its 95% confidence interval. The Newcastle-Ottawa scale was used for quantity assessment. Subgroup and sensitivity analysis were conducted to explore sources of heterogeneity. The Gene Expression Omnibus (GEO) and The Cancer Genome Atlas (TCGA) were employed for bioinformatics analysis on the correlation between MLH1 methylation and GC risk, clinicopathological behavior as well as prognosis. Results: 2365 GC and 1563 controls were included in the meta-analysis. The pooled OR of MLH1 methylation in GC was 4.895 (95% CI: 3.149-7.611, P<0.001), which considerably associated with increased GC risk. No significant difference was found in relation to Lauren classification, tumor invasion, lymph node/distant metastasis and tumor stage in GC. Analysis based on GEO and TCGA showed that high MLH1 methylation enhanced GC risk but might not related with GC clinicopathological features and prognosis. Conclusion: MLH1 methylation is an alive biomarker for the prediction of GC and it might not affect GC behavior. Further study could be conducted to verify the impact of MLH1 methylation on GC prognosis. PMID:29896277
Keshet, U; Alon, T; Fialkov, A B; Amirav, A
2017-07-01
An Open Probe inlet was combined with a low thermal mass ultra-fast gas chromatograph (GC), in-vacuum electron ionization ion source and a mass spectrometer (MS) of GC-MS for obtaining real-time analysis with separation. The Open Probe enables ambient sampling via sample vaporization in an oven that is open to room air, and the ultra-fast GC provides ~30-s separation, while if no separation is required, it can act as a transfer line with 2 to 3-s sample transfer time. Sample analysis is as simple as touching the sample, pushing the sample holder into the Open Probe oven and obtaining the results in 30 s. The Open Probe fast GC was mounted on a standard Agilent 7890 GC that was coupled with an Agilent 5977A MS. Open Probe fast GC-MS provides real-time analysis combined with GC separation and library identification, and it uses the low-cost MS of GC-MS. The operation of Open Probe fast GC-MS is demonstrated in the 30-s separation and 50-s full analysis cycle time of tetrahydrocannabinol and cannabinol in Cannabis flower, sub 1-min analysis of trace trinitrotoluene transferred from a finger onto a glass surface, vitamin E in canola oil, sterols in olive oil, polybrominated flame retardants in plastics, alprazolam in Xanax drug pill and free fatty acids and cholesterol in human blood. The extrapolated limit of detection for pyrene is <1 fg, but the concentration is too high and the software noise calculation is untrustworthy. The broad range of compounds amenable for analysis is demonstrated in the analysis of reserpine. The possible use with alternate standard GC-MS and Open Probe fast GC-MS is demonstrated in the analysis of heroin in its street drug powder. The use of Open Probe with the fast GC acting as a transfer line is demonstrated in <10-s analysis without separation of ibuprofen and estradiol. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Cha, Eunju; Kim, Sohee; Kim, Ho Jun; Lee, Kang Mi; Kim, Ki Hun; Kwon, Oh-Seung; Lee, Jaeick
2015-01-01
This study compared the sensitivity of various separation and ionization methods, including gas chromatography with an electron ionization source (GC-EI), liquid chromatography with an electrospray ionization source (LC-ESI), and liquid chromatography with a silver ion coordination ion spray source (LC-Ag(+) CIS), coupled to a mass spectrometer (MS) for steroid analysis. Chromatographic conditions, mass spectrometric transitions, and ion source parameters were optimized. The majority of steroids in GC-EI/MS/MS and LC-Ag(+) CIS/MS/MS analysis showed higher sensitivities than those obtained with other analytical methods. The limits of detection (LODs) of 65 steroids by GC-EI/MS/MS, 68 steroids by LC-Ag(+) CIS/MS/MS, 56 steroids by GC-EI/MS, 54 steroids by LC-ESI/MS/MS, and 27 steroids by GC-ESI/MS/MS were below cut-off value of 2.0 ng/mL. LODs of steroids that formed protonated ions in LC-ESI/MS/MS analysis were all lower than the cut-off value. Several steroids such as unconjugated C3-hydroxyl with C17-hydroxyl structure showed higher sensitivities in GC-EI/MS/MS analysis relative to those obtained using the LC-based methods. The steroids containing 4, 9, 11-triene structures showed relatively poor sensitivities in GC-EI/MS and GC-ESI/MS/MS analysis. The results of this study provide information that may be useful for selecting suitable analytical methods for confirmatory analysis of steroids. Copyright © 2015 John Wiley & Sons, Ltd.
USDA-ARS?s Scientific Manuscript database
Flavor profiles of two Florida strawberry cultivars were determined using GC-olfactometry,GC-MS, odor activity values (OAVs) and sensory analysis. Thirty-six aroma active compounds were detected using GC-O. Thirty-four were identified. The major odor-active compounds in decreasing intensity were: me...
Principles of Micellar Electrokinetic Capillary Chromatography Applied in Pharmaceutical Analysis
Hancu, Gabriel; Simon, Brigitta; Rusu, Aura; Mircia, Eleonora; Gyéresi, Árpád
2013-01-01
Since its introduction capillary electrophoresis has shown great potential in areas where electrophoretic techniques have rarely been used before, including here the analysis of pharmaceutical substances. The large majority of pharmaceutical substances are neutral from electrophoretic point of view, consequently separations by the classic capillary zone electrophoresis; where separation is based on the differences between the own electrophoretic mobilities of the analytes; are hard to achieve. Micellar electrokinetic capillary chromatography, a hybrid method that combines chromatographic and electrophoretic separation principles, extends the applicability of capillary electrophoretic methods to neutral analytes. In micellar electrokinetic capillary chromatography, surfactants are added to the buffer solution in concentration above their critical micellar concentrations, consequently micelles are formed; micelles that undergo electrophoretic migration like any other charged particle. The separation is based on the differential partitioning of an analyte between the two-phase system: the mobile aqueous phase and micellar pseudostationary phase. The present paper aims to summarize the basic aspects regarding separation principles and practical applications of micellar electrokinetic capillary chromatography, with particular attention to those relevant in pharmaceutical analysis. PMID:24312804
Matrix-enhanced degradation of p,p'-DDT during gas chromatographic analysis: A consideration
Foreman, W.T.; Gates, Paul M.
1997-01-01
Analysis of p,p‘-DDT in environmental samples requires monitoring the GC-derived breakdown of this insecticide, which produces p,p‘-DDD and/or p,p‘-DDE, both also primary environmental degradation products. A performance evaluation standard (PES) containing p,p‘-DDT but notp,p‘-DDD or p,p‘-DDE can be injected at regular intervals throughout an analytical sequence to monitor GC degradation. Some U.S. EPA methods limit GC breakdown of DDT in the PES to ≤20%. GC/MS analysis of large-volume natural water samples fortified with deuterium- and 13C-labeled p,p‘-DDT exhibited up to 65% DDT breakdown by the GC inlet. These matrix-enhanced GC degradation amounts substantially exceeded the <20% breakdown levels indicated by bracketing injections of the PES containing unlabeled and labeled DDT. Substantial matrix-enhanced GC degradation was not observed during analysis of a limited number of fractionated bed-sediment extracts containing labeled DDT. Use of isotopically labeled DDT seems to provide an effective tool for monitoring sample-specific DDT breakdown during GC/MS analysis. However, analyte co-elutions render impractical their use in GC/ECD analysis. The oc currence of matrix-enhanced GC degradation might have important implications on data quality and the resultant interpretations of the environmental degradation of DDT and other thermolabile contaminants.
Zhao, Yanni; Zhao, Jieyu; Zhao, Chunxia; Zhou, Huina; Li, Yanli; Zhang, Junjie; Li, Lili; Hu, Chunxiu; Li, Wenzheng; Peng, Xiaojun; Lu, Xin; Lin, Fucheng; Xu, Guowang
2015-01-01
Ecological conditions and developmental senescence significantly affect the physiological metabolism of plants, yet relatively little is known about the influence of geographical location on dynamic changes in plant leaves during growth. Pseudotargeted gas chromatography-selected ion monitoring-mass spectrometry and capillary electrophoresis-mass spectrometry were used to investigate a time course of the metabolic responses of tobacco leaves to geographical location. Principal component analysis revealed obvious metabolic discrimination between growing districts relative to cultivars. A complex carbon and nitrogen metabolic network was modulated by environmental factors during growth. When the Xuchang and Dali Districts in China were compared, the results indicated that higher rates of photosynthesis, photorespiration and respiration were utilized in Xuchang District to generate the energy and carbon skeletons needed for the biosynthesis of nitrogen-containing metabolites. The increased abundance of defense-associated metabolites generated from the shikimate-phenylpropanoid pathway in Xuchang relative to Dali was implicated in protection against stress. PMID:26549189
HRM and SNaPshot as alternative forensic SNP genotyping methods.
Mehta, Bhavik; Daniel, Runa; McNevin, Dennis
2017-09-01
Single nucleotide polymorphisms (SNPs) have been widely used in forensics for prediction of identity, biogeographical ancestry (BGA) and externally visible characteristics (EVCs). Single base extension (SBE) assays, most notably SNaPshot® (Thermo Fisher Scientific), are commonly used for forensic SNP genotyping as they can be employed on standard instrumentation in forensic laboratories (e.g. capillary electrophoresis). High resolution melt (HRM) analysis is an alternative method and is a simple, fast, single tube assay for low throughput SNP typing. This study compares HRM and SNaPshot®. HRM produced reproducible and concordant genotypes at 500 pg, however, difficulties were encountered when genotyping SNPs with high GC content in flanking regions and differentiating variants of symmetrical SNPs. SNaPshot® was reproducible at 100 pg and is less dependent on SNP choice. HRM has a shorter processing time in comparison to SNaPshot®, avoids post PCR contamination risk and has potential as a screening tool for many forensic applications.
Device to improve detection in electro-chromatography
Garguilo, Michael G.; Paul, Phillip H.; Rakestraw, David J.
2000-01-01
Apparatus and method for improving the resolution of non-pressure driven capillary chromatographic systems, and particularly for capillary electrochromatography (CEC) systems. By reducing the cross-sectional area of a packed capillary column by means of a second open capillary contiguous with the outlet end of a packed capillary column, where the packed capillary column has a cross sectional area of between about 2 and 5 times that of the open capillary column, the phenomenon of band broadening in the transition region between the open capillary and the packed capillary column, where the individual components of the mixture are analyzed, can be eliminated, thereby providing for a significant improvement in resolution and more accurate detection and analysis.
Device to improve detection in electro-chromatography
Garguilo, Michael G.; Paul, Phillip H.; Rakestraw, David J.
2002-01-01
Apparatus and method for improving the resolution of non-pressure driven capillary chromatographic systems, and particularly for capillary electrochromatography (CEC) systems. By reducing the cross-sectional area of a packed capillary column by means of a second open capillary contiguous with the outlet end of a packed capillary column, where the packed capillary column has a cross sectional area of between about 2 and 5 times that of the open capillary column, the phenomenon of band broadening in the transition region between the open capillary and the packed capillary column, where the individual components of the mixture are analyzed, can be eliminated, thereby providing for a significant improvement in resolution and more accurate detection and analysis.
Postoperative granuloma after stapedectomy: is it destiny or avoidable?
Batman, C; Oztürk, O; Ramadan, S S
2007-01-01
The aims of this study were (1) to investigate the pathophysiological characteristics of the middle ear mucoperiosteum against the caustic nature of the gastric content (GC), which consists largely of acid and pepsin components, and (2) to investigate the possible role of gastroesophageal reflux and postoperative vomiting (POV) in the etiology of poststapedectomy granuloma. 40 Spraque-Dawley rats of either sex and with a body weight of 200-300 g were used, and divided into different study groups: group 1: GC administration to the middle ear (n = 8); group 2: phosphate-buffered saline administration to the middle ear (n = 8); group 3: GC (pH: 2) administration in the presence of a Teflon piston (TP) (n = 6); group 4: phosphate-buffered saline administration in the presence of a TP (n = 6); group 5: GC administration in the presence of a wired piston (WP) (n = 6); group 6: phosphate- buffered saline administration in the presence of a WP (n = 6). GC was administrated to the middle ear cavities by way of the eustachian tube (ET). In order to overcome the pressure of the ET, a pump mechanism was used. The increased nasopharyngeal pressure caused a passive opening of the ET, and transferred a bolus to the middle ear. The animals were decapitated after 1 week, and the bullae were isolated. The tympanic bullae were serially cut and examined with light microscopy. In the saline controls, there was only a mild amount of polymorphonuclear cell (PMN) infiltration in the mildly thickened subepithelial space, indicating a less pronounced inflammation as compared to the gastric acid group. In the GC group, in addition to focal hemorrhage and severe subepithelial infiltration of PMNs, the middle ear mucosa was dramatically thickened with subepithelial edema and dilated capillaries. In the subepithelial tissue, retention cysts and granulation tissue were present. In the piston groups (TP and WP), there was extensive subepithelial inflammation and edema after GC and saline administrations. Granulation tissue filling the entire bulla around the piston segments was detected. The relationship between the administration of GC and middle ear inflammation, and the possible role of POV in the etiology of poststapedectomy granuloma are emphasized with our experimental study. The length of the TP may be considerably important to prevent POV which may lead to gastric reflux to the middle ear.
Fleming, Susannah; Gill, Peter; Jones, Caroline; Taylor, James A.; Van den Bruel, Ann; Heneghan, Carl; Roberts, Nia; Thompson, Matthew
2015-01-01
Importance Capillary refill time (CRT) is widely recommended as part of the routine assessment of unwell children. Objective To determine the diagnostic value of capillary refill time for a range of serious outcomes in children. Methods We searched Medline, Embase and CINAHL from inception to June 2014. We included studies that measured both capillary refill time and a relevant clinical outcome such as mortality, dehydration, meningitis, or other serious illnesses in children aged up to 18 years of age. We screened 1,265 references, of which 24 papers were included in this review. Where sufficient studies were available, we conducted meta-analysis and constructed hierarchical summary ROC curves. Results Meta-analysis on the relationship between capillary refill time and mortality resulted in sensitivity of 34.6% (95% CI 23.9 to 47.1%), specificity 92.3% (88.6 to 94.8%), positive likelihood ratio 4.49 (3.06 to 6.57), and negative likelihood ratio 0.71 (0.60 to 0.84). Studies of children attending Emergency Departments with vomiting and diarrhea showed that capillary refill time had specificity of 89 to 94% for identifying 5% dehydration, but sensitivity ranged from 0 to 94%. This level of heterogeneity precluded formal meta-analysis of this outcome. Meta-analysis was not possible for other outcomes due to insufficient data, but we found consistently high specificity for a range of outcomes including meningitis, sepsis, admission to hospital, hypoxia, severity of illness and dengue. Conclusions Our results show that capillary refill time is a specific sign, indicating that it can be used as a “red-flag”: children with prolonged capillary refill time have a four-fold risk of dying compared to children with normal capillary refill time. The low sensitivity means that a normal capillary refill time should not reassure clinicians. PMID:26375953
Wang, Xiaogang; Qi, Meiling; Fu, Ruonong
2014-12-05
Here we report the separation performance of a new stationary phase of cucurbit[7]uril (CB7) incorporated into an ionic liquid-based sol-gel coating (CB7-SG) for capillary gas chromatography (GC). The CB7-SG stationary phase showed an average polarity of 455, suggesting its polar nature. Abraham system constants revealed that its major interactions with analytes include H-bond basicity (a), dipole-dipole (s) and dispersive (l) interactions. The CB7-SG stationary phase achieved baseline separation for a wide range of analytes with symmetrical peak shapes and showed advantages over the conventional polar stationary phase that failed to resolve some critical analytes. Also, it exhibited different retention behaviors from the conventional stationary phase in terms of retention times and elution order. Most interestingly, in contrast to the conventional polar phase, the CB7-SG stationary phase exhibited longer retentions for analytes of lower polarity but relatively comparable retentions for polar analytes such as alcohols and phenols. The high resolving ability and unique retention behaviors of the CB7-SG stationary phase may stem from the comprehensive interactions of the aforementioned interactions and shape selectivity. Moreover, the CB7-SG column showed good peak shapes for analytes prone to peak tailing, good thermal stability up to 280°C and separation repeatability with RSD values in the range of 0.01-0.11% for intra-day, 0.04-0.41% for inter-day and 2.5-6.0% for column-to-column, respectively. As demonstrated, the proposed coating method can simultaneously address the solubility problem with CBs for the intended purpose and achieve outstanding GC separation performance. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Plummer, R. E.; Pohlman, J. W.; Coffin, R. B.
2005-12-01
A system has been developed to measure the stable carbon isotope (δ13C) composition of dissolved methane, ethane, and propane from natural sediment samples with headspace concentrations as low as 1 ppm using a modified Thermo Electron Trace gas chromatograph (GC) connected to a Finnigan Delta Plus XP isotope ratio mass spectrometer (IRMS). A cryofocusing inlet was connected to the GC which allows 0.02- to 15.0-ml injections into a 10-ml min-1 He carrier stream. Analytes from the variable-volume injection are focused into a small section of fused silica capillary, which is either empty or packed with Poraplot-Q, depending on the analyte(s) of interest. The analytes are then rapidly desorbed (100°C) onto the GC column (1.8 ml min-1), where they undergo separation, combustion and IRMS detection. The sensitivity of the IRMS was improved by the addition of high resistivity amplifiers so that measurements can be obtained with as little as 7-ng of carbon. The analytical precision (2σ) is less than 0.5‰ for methane analysis and less than 1‰ for ethane and propane analyses. The gases are standardized by tank CO2 which has been referenced to the NIST RM 8560 natural gas standard. The samples require no pretreatment, and can be analyzed rapidly (20 samples/day) and with minimal instrument training. Using this system, we have obtained complete stable carbon isotope ethane profiles from sediment cores from microbial and thermogenic gas hydrate regions on the Northern Cascadia Margin. We were able to differentiate the relative thermal and microbial contributions of the gases; and furthermore, we obtained clear evidence for ethanogenesis and ethane oxidation at depths similar to those where methanogenesis and anaerobic methane oxidation (AOM), respectively, occurred. This system will be utilized to analyze headspace and hydrate gas samples from IODP Leg 311. These data will allow us to fully characterize the thermogenic contributions and trace hydrocarbon biogeochemical cycling of hydrocarbons along the Expedition 311 margin-perpendicular transect.
Dumasia, M C; Ginn, A; Hyde, W; Peterson, J; Houghton, E
2003-05-25
Rimadyl (carprofen) was administered orally to the racing greyhound at a dose of 2.2 mg kg(-1). Following both alkaline and enzymatic hydrolysis, postadministration urine samples were extracted by mixed mode solid-phase extraction (SPE) cartridges to identify target analyte(s) for forensic screening and confirmatory analysis methods. The acidic isolates were derivatised as trimethylsilyl ethers (TMS) and analysed by gas chromatography-mass spectrometry (GC-MS). Carprofen and five phase I metabolites were identified. Positive ion electron ionisation (EI(+)) mass spectra of the TMS derivatives of carprofen and its metabolites show a diagnostic base peak at M(+)*. -117 corresponding to the loss of COO-Si-(CH(3))(3) group as a radical. GC-MS with positive ion ammonia chemical ionisation (CI(+)) of the compounds provided both derivatised molecular mass and some structural information. Deutromethylation-TMS derivatisation was used to distinguish between aromatic and aliphatic oxidations of carprofen. The drug is rapidly absorbed, extensively metabolised and excreted as phase II conjugates in urine. Carprofen, three aromatic hydroxy and a minor N-hydroxy metabolite were detected for up to 48 h. For samples collected between 2 and 8 h after administration, the concentration of total carprofen ranged between 200 and 490 ng ml(-1). The major metabolite, alpha-hydroxycarprofen was detected for over 72 h and therefore can also be used as a marker for the forensic screening of carprofen in greyhound urine.
Monolithic graphene fibers for solid-phase microextraction.
Fan, Jing; Dong, Zelin; Qi, Meiling; Fu, Ruonong; Qu, Liangti
2013-12-13
Monolithic graphene fibers for solid-phase microextraction (SPME) were fabricated through a dimensionally confined hydrothermal strategy and their extraction performance was evaluated. For the fiber fabrication, a glass pipeline was innovatively used as a hydrothermal reactor instead of a Teflon-lined autoclave. Compared with conventional methods for SPME fibers, the proposed strategy can fabricate a uniform graphene fiber as long as several meters or more at a time. Coupled to capillary gas chromatography (GC), the monolithic graphene fibers in a direct-immersion (DI) mode achieved higher extraction efficiencies for aromatics than those for n-alkanes, especially for polycyclic aromatic hydrocarbons (PAHs), thanks to π-π stacking interaction and hydrophobic effect. Additionally, the fibers exhibited excellent durability and can be repetitively used more than 160 times without significant loss of extraction performance. As a result, an optimum extraction condition of 40°C for 50min with 20% NaCl (w/w) was finally used for SPME of PAHs in aqueous samples. For the determination of PAHs in water samples, the proposed DI-SPME-GC method exhibited linear range of 0.05-200μg/L, limits of detection (LOD) of 4.0-50ng/L, relative standard deviation (RSD) less than 9.4% and 12.1% for one fiber and different fibers, respectively, and recoveries of 78.9-115.9%. The proposed method can be used for analysis of PAHs in environmental water samples. Copyright © 2013 Elsevier B.V. All rights reserved.
Li, Siyan; Lu, Chengwei; Zhu, Fang; Jiang, Ruifen; Ouyang, Gangfeng
2015-05-11
In this work, a C18 composite solid-phase microextraction (SPME) fiber was prepared with a new method and applied to the analysis of organochlorine pesticides (OCPs) in water sample. A stainless steel wire (o.d. 127 μm) was used as the substrate, and a mixture of the C18 particle (3.5 μm) and the 184 silicone was used as the coating material. During the process of fiber preparation, a section of capillary column was used to fix the mixture onto the stainless steel wire and to ensure the constant of coating thickness. The prepared fiber showed excellent thermal stability and solvent resistance. By coupling with gas chromatography-mass spectrometry (GC-MS), the fiber exhibited wide linearity (2-500 ng L(-1)) and good sensitivity for the determination of six OCPs in water samples, the OCPs tested included hexachlorobezene, trans-chlordane, cis-chlordane, o,p-DDT, p,p-DDT and mirex. Not only the extraction performance of the newly prepared fiber was more than seven times higher than those of commercial fibers, the limits of detections (LODs) (0.059-0.151 ng L(-1)) for OCPs achieved under optimized conditions were also lower than those of reported SPME methods. The fiber was successfully applied to the determination of OCPs in real water samples by using developed SPME-GC-MS method. Copyright © 2015 Elsevier B.V. All rights reserved.
Page, B D; Lacroix, G M
1992-01-01
Retail samples of Canadian butter and margarine wrapped in aluminium foil-paper laminate were found to contain dibutyl, butyl benzyl and/or di-2-ethylhexyl phthalate (DBP, BBP, DEHP) as packaging migrants at levels up to 10.6, 47.8 and 11.9 micrograms/g, respectively. These phthalates were determined by capillary gas chromatography with flame ionization detection (GC-FID) after clean-up of the separated oil by sweep co-distillation. The phthalate esters found in the contacted butter or margarine were also found in the contacting wrappers. They were determined in wrapper extracts by liquid chromatography with diode array detection or by GC-FID. Analysis of unused wrappers showed 76-88% of the total DBP and DEHP to be present on the foil (outer) surface as a component of the protective coating (washcoat). The remainder of the DBP and DEHP was found on the food-contacting paper surface, presumably by transfer from the outer to inner surface during storage in tightly wound rolls, although transfer of phthalate esters, if present in the paper-foil adhesive, cannot be ruled out. Food-contacting surface concentrations of DBP and DEHP were found to be 2.4 to 4.7 and 2.8 to 3.6 micrograms/cm2, respectively. Samples of each packaging component: paper, foil, adhesive, washcoat and inks were analysed for phthalate esters and only the washcoat was found to contain phthalate esters.
Chen, Xingguo; Fazal, Md. Abul; Dovichi, Norman J.
2007-01-01
Two-dimensional capillary electrophoresis was used for the separation of proteins and biogenic amines from the mouse AtT-20 cell line. The first-dimension capillary contained a TRIS-CHES-SDS-dextran buffer to perform capillary sieving electrophoresis, which is based on molecular weight of proteins. The second-dimension capillary contained a TRIS-CHES-SDS buffer for micel1ar electrokinetic capillary chromatography. After a 61 seconds preliminary separation, fractions from the first-dimension capillary were successively transferred to the second-dimension capillary, where they further separated by MECC. The two-dimensional separation required 60 minutes. PMID:17637850
NASA Astrophysics Data System (ADS)
Gallego, E.; Roca, F. X.; Perales, F.; Ribes, A.; Carrera, G.; Guardino, X.; Berenguer, M. J.
Isocyanatocyclohexane and isothiocyanatocyclohexane are becoming relevant compounds in urban and industrial air, as they are used in important amounts in automobile industry and building insulation, as well as in the manufacture of foams, rubber, paints and varnishes. Glass multi-sorbent tubes (Carbotrap, Carbopack, Carboxen) were connected to LCMA-UPC pump samplers for the retention of iso- and isothiocyanatocyclohexanes. The analysis was performed by automatic thermal desorption (ATD) coupled with capillary gas chromatography (GC)/mass spectrometry detector (MSD). TD-GC/MS was chosen as analytical method due to its versatility and the possibility of analysis of a wide range of volatility and polarity VOC in air samples. The method was satisfactory sensitive, selective and reproducible for the studied compounds. The concentrations of iso- and isothioisocyanatocyclohexanes were evaluated in different urban, residential and industrial locations from extensive VOC air quality and odour episode studies in several cities in the Northeastern edge of Spain. Around 200-300 VOC were determined qualitatively in each sample. Higher values of iso- and isothiocyanatocyclohexane were found in industrial areas than in urban or residential locations. The concentrations ranged between n.d.-246 and n.d.-29 μg m -3 for isocyanatocyclohexane and isothiocyanatocyclohexane, respectively, for industrial areas. On the other hand, urban and residential locations showed concentrations ranging between n.d.-164 and n.d.-29 μg m -3 for isocyanatocyclohexane and isothiocyanatocyclohexane, respectively. The site location (urban or industrial), the kind and nearness of possible iso- and isothiocyanatocyclohexane emission activities (industrial or building construction) and the changes of wind regimes throughout the year have been found the most important factors influencing the concentrations of these compounds in the different places.
Multiplexed fluorescence detector system for capillary electrophoresis
Yeung, E.S.; Taylor, J.A.
1996-03-12
A fluorescence detection system for capillary electrophoresis is provided wherein the detection system can simultaneously excite fluorescence and substantially simultaneously monitor separations in multiple capillaries. This multiplexing approach involves laser irradiation of a sample in a plurality of capillaries through optical fibers that are coupled individually with the capillaries. The array is imaged orthogonally through a microscope onto a charge-coupled device camera for signal analysis. 14 figs.
Multiplexed fluorescence detector system for capillary electrophoresis
Yeung, E.S.; Taylor, J.A.
1994-06-28
A fluorescence detection system for capillary electrophoresis is provided wherein the detection system can simultaneously excite fluorescence and substantially simultaneously monitor separations in multiple capillaries. This multiplexing approach involves laser irradiation of a sample in a plurality of capillaries through optical fibers that are coupled individually with the capillaries. The array is imaged orthogonally through a microscope onto a charge-coupled device camera for signal analysis. 14 figures.
Multiplexed fluorescence detector system for capillary electrophoresis
Yeung, Edward S.; Taylor, John A.
1996-03-12
A fluorescence detection system for capillary electrophoresis is provided wherein the detection system can simultaneously excite fluorescence and substantially simultaneously monitor separations in multiple capillaries. This multiplexing approach involves laser irradiation of a sample in a plurality of capillaries through optical fibers that are coupled individually with the capillaries. The array is imaged orthogonally through a microscope onto a charge-coupled device camera for signal analysis.
Multiplexed fluorescence detector system for capillary electrophoresis
Yeung, Edward S.; Taylor, John A.
1994-06-28
A fluorescence detection system for capillary electrophoresis is provided wherein the detection system can simultaneously excite fluorescence and substantially simultaneously monitor separations in multiple capillaries. This multiplexing approach involves laser irradiation of a sample in a plurality of capillaries through optical fibers that are coupled individually with the capillaries. The array is imaged orthogonally through a microscope onto a charge-coupled device camera for signal analysis.
Lara-Ramírez, Edgar E.; Salazar, Ma Isabel; López-López, María de Jesús; Salas-Benito, Juan Santiago; Sánchez-Varela, Alejandro
2014-01-01
The increasing number of dengue virus (DENV) genome sequences available allows identifying the contributing factors to DENV evolution. In the present study, the codon usage in serotypes 1–4 (DENV1–4) has been explored for 3047 sequenced genomes using different statistics methods. The correlation analysis of total GC content (GC) with GC content at the three nucleotide positions of codons (GC1, GC2, and GC3) as well as the effective number of codons (ENC, ENCp) versus GC3 plots revealed mutational bias and purifying selection pressures as the major forces influencing the codon usage, but with distinct pressure on specific nucleotide position in the codon. The correspondence analysis (CA) and clustering analysis on relative synonymous codon usage (RSCU) within each serotype showed similar clustering patterns to the phylogenetic analysis of nucleotide sequences for DENV1–4. These clustering patterns are strongly related to the virus geographic origin. The phylogenetic dependence analysis also suggests that stabilizing selection acts on the codon usage bias. Our analysis of a large scale reveals new feature on DENV genomic evolution. PMID:25136631
Nguyen, Thi Anh Huong; Pham, Thi Ngoc Mai; Ta, Thi Thao; Nguyen, Xuan Truong; Nguyen, Thi Lien; Le, Thi Hong Hao; Koenka, Israel Joel; Sáiz, Jorge; Hauser, Peter C; Mai, Thanh Duc
2015-12-01
A simple and inexpensive method for the identification of four substituted amphetamines, namely, 3,4-methylenedioxy methamphetamine (MDMA), methamphetamine (MA), 3,4-methylenedioxy amphetamine (MDA) and 3,4-methylenedioxy-N-ethylamphetamine (MDEA) was developed using an in-house constructed semi-automated portable capillary electrophoresis instrument (CE) with capacitively coupled contactless conductivity detection (C(4)D). Arginine 10mM adjusted to pH4.5 with acetic acid was found to be the optimal background electrolyte for the CE-C(4)D determination of these compounds. The best detection limits achieved with and without a sample preconcentration process were 10ppb and 500ppb, respectively. Substituted amphetamines were found in different seized illicit club drug tablets and urine samples collected from different suspected users. Good agreement between results from CE-C(4)D and those with the confirmation method (GC-MS) was achieved, with correlation coefficients for the two pairs of data of more than 0.99. Copyright © 2015 The Chartered Society of Forensic Sciences. Published by Elsevier Ireland Ltd. All rights reserved.
Ionic liquids as stationary phases for fatty acid analysis by gas chromatography.
Fanali, C; Micalizzi, G; Dugo, P; Mondello, L
2017-12-04
The present paper provides an overview of the application of ionic liquid (IL) columns for GC analysis of fatty acid methyl esters (FAMEs). Although their separation can be carried out utilizing GC columns containing polar stationary phases, some ILs have been employed as stationary phases, either commercial or laboratory made, in GC analysis. Monodimensional and bidimensional GC methods have been optimized in order to achieve the best separation especially considering the geometric and positional isomers of unsaturated fatty acids. Several methods for the analysis of trans-fatty acids have also been reported. The use of GC-GC, using either the same IL columns or different columns in the first and second dimensions, allowed the separation of a large number of FAMEs. The application of the IL columns for GC analysis of FAMEs in different types of real samples is described, e.g., oil of different nature (fish, flaxseed, and olive), margarine and butter, biodiesel, milk, bacteria etc.
NASA Astrophysics Data System (ADS)
Luo, X.; Zhu, W.; Mitra, B.; Liu, J.; Liu, T.; Fan, X.; Gianchandani, Y.
2011-12-01
There is increasing interest in miniaturized systems for chemical analysis in harsh environments. Chemical detection by emission spectroscopy of on-chip microdischarges [1-3] can be performed at >200°C [4], suggesting utility inspace exploration, volcanic monitoring, and oil well monitoring. This abstract describes the first use of pulsed microdischarge spectroscopy for gas chromatography (GC).This effort supports NASA interests in monitoring closed-loop life support systems for spacecraft. The microdischarge occurs on a 1cm2 glass chip (Fig. 1a), with thin-film Ni electrodes separated by 160μm. A glass lid with a grooved gas-flow channel, and inlet/outlet capillary tubes are epoxy-sealed to the chip. Located downstream of the 1.7m-long, RTX-1-coated, GC separation column, the microdischarge chip is read by a spectrometer. In a typical experiment (Fig. 1b), a mixture of acetone 3.6μg, 1-hexanol 2.8μg and nitrobenzene 3.0μg, is injected, with He carrier gas at 1.56sccm, through the GC. Acetone elutes quickly while nitrobenzene is slower. Microdischarges are triggered at 0.5Hz for 6 min., and 0.04Hz thereafter. Each microdischarge consumes ≈8mJ; the average power is ≈1.14mW. The spectrum (Fig. 1b, inset) shows that the 388nm peak, representing CN/CH fragments [5], is enhanced by carbon compounds. Its strength relative to the 588nm peak of He provides a chromatogram. Fig. 1b also shows a benchmark result from a commercial flame ionization detector (FID). The differences in elution time are attributed to differences in the gas flow paths for the two detectors [1]. REFERENCES [1] Eijkel et al, Anal. Chem, 2000 [2] Mitra et al, IEEE Trans Plasma Sci, 2008 [3] Mitra et al, IEEE Sensors, 2008 [4] Wright et al, APL, 2009 [5] Pearse et al, The Identification of Molecular Spectra, 1963
Flow Analysis of Isobutane (R-600A) Inside AN Adiabatic Capillary Tube
NASA Astrophysics Data System (ADS)
Alok, Praveen; Sahu, Debjyoti
2018-02-01
Capillary tubes are simple narrow tubes but the phase change which occurs inside the capillary tubes is complex to analyze. In the present investigation, an attempt is made to analyze the flow of Isobutane (R-600a) inside the coiled capillary tubes for different load conditions by Homogeneous Equilibrium Model. The Length and diameter of the capillary tube not only depend on the pressure and temperature of the condenser and evaporator but also on the cooling load. The present paper investigates the change in dimensions of the coil capillary tube with respect to the change in cooling load on the system for the constant condenser and evaporator conditions. ANSYS CFX (Central Florida Expressway) software is used to study the flow characteristics of the refrigerant. Appropriate helical coil is selected for this analysis.
Dembitsky, V M; Dor, I; Shkrob, I
2000-12-01
A study of lipids of the soil cyanobacterium Microcoleus vaginatus, which was isolated from microbial crusts collected in the Dead Sea basin and in the Negev desert, was performed. Twenty-six hydrocarbons and fatty acids were separated and identified by GC/MS using serially coupled capillary columns of different polarity. Changes in the lipid composition were evaluated by comparison of samples collected from different locations. Heptadecane, 1-heptadecene, 6- and 7-methylheptadecane, hexadecanoic and 9(Z)-octadecenoic acids were identified as the major constituents. Biochemical mechanisms of production of the different lipid compounds under UV irradiation are proposed.
Padalia, Rajendra C; Verma, Ram S; Chauhan, Amit; Goswami, Prakash; Chanotiya, Chandan S; Saroj, Arvind; Samad, Abdul; Khaliq, Abdul
2014-10-01
The composition of hydrodistilled essential oils of Ocimum basilicum L. (four chemovariants), O. tenuiflorum L., O. gratissimum L., and O. kilimandscharicum Guerke were analyzed and compared by using capillary gas chromatography (GC/FID) and GC-mass spectrometry (GC/MS). Phenyl propanoids (upto 87.0%) and monoterpenoids (upto 83.3%) were prevalent constituents distributed in the studied Ocimum taxa. The major constituents of the four distinct chemovariants of O. basilicum were methyl chavicol (86.3%), methyl chavicol (61.5%)/linalool (28.6%), citral (65.9%); and linalool (36.1%)/citral (28.8%). Eugenol (66.5% and 78.0%) was the major constituent of O. tenuiflorum and O. gratissimum. Eugenol (34.0%), β-bisabolene (15.4%), (E)-α-bisabolene (10.9%), methyl chavicol (10.2%) and 1,8-cineole (8.2%) were the major constituents of O. kilimandscharicum. In order to explore the potential for industrial use, the extracted essential oils were assessed for their antifungal potential through poison food technique against two phytopathogens, Rhizoctonia solani and Choanephora cucurbitarum, which cause root and wet rot diseases in various crops. O. tenuiflorum, O. gratissimum, and O. kilimandscharicum exhibited complete growth inhibition against R. solani and C. cucurbitarum after 24 and 48 h of treatment. O. basilicum chemotypes showed variable levels of growth inhibition (63.0%-100%) against these two phytopathogens.
Gentili, Stefano; Mortali, Claudia; Mastrobattista, Luisa; Berretta, Paolo; Zaami, Simona
2016-09-10
A procedure based on headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography/mass spectrometry (GC/MS) has been developed for the determination of most commonly used drugs of abuse in sweat of drivers stopped during roadside controls. DrugWipe 5A sweat screening device was used to collect sweat by a specific pad rubbed gently over forehead skin surface. The procedure involved an acid hydrolysis, a HS-SPME extraction for drugs of abuse but Δ(9)-tetrahydrocannabinol, which was directly extracted in alkaline medium HS-SPME conditions, a GC separation of analytes by a capillary column and MS detection by electron impact ionisation. The method was linear from the limit of quantification (LOQ) to 50ng drug per pad (r(2)≥0.99), with an intra- and inter-assay precision and accuracy always less than 15% and an analytical recovery between 95.1% and 102.8%, depending on the considered analyte. Using the validated method, sweat from 60 apparently intoxicated drivers were found positive to one or more drugs of abuse, showing sweat patches testing as a viable economic and simple alternative to conventional (blood and/or urine) and non conventional (oral fluid) testing of drugs of abuse in drugged drivers. Copyright © 2016 Elsevier B.V. All rights reserved.
Chojnacka, Aleksandra; Ghaffar, Abdul; Feilden, Andrew; Treacher, Kevin; Janssen, Hans-Gerd; Schoenmakers, Peter
2011-11-14
Knowledge on the solubility behaviour and dissolution rate of speciality and commodity polymers is very important for the use of such materials in high-tech applications. We have developed methods for the quantification and characterization of dissolved copolymers of N-vinyl-2-pyrrolidone (VP) and vinyl acetate (VA) during dissolution in water. The methods are based on pyrolysis (Py) performed in a programmed-temperature vaporization injector with subsequent identification and quantification of the components in the pyrolysate using capillary gas chromatography-mass spectrometry (GC-MS). By injecting large volumes and applying cryo-focussing at the top of the column, low detection limits could be achieved. The monomer ratio was found to have the greatest effect on the dissolution rate of the PVP-co-VA copolymers. The material with the highest amount of VA (50%) dissolves significantly slower than the other grades. Size-exclusion chromatography (SEC) and Py-GC-MS were used to measure molecular weights and average chemical compositions, respectively. Combined off-line SEC//Py-GC-MS was used to determine the copolymer composition (VP/VA ratio), as a function of the molecular weight for the pure polymers. In the dissolution experiments, a constant VP/VA ratio across the dissolution curve was observed for all copolymers analysed. This suggests a random distribution of the two monomers over the molecules. Copyright © 2011 Elsevier B.V. All rights reserved.
García, Antonia; Rupérez, Francisco J; Ceppa, Florencia; Pellati, Federica; Barbas, Coral
2012-03-05
The classification of an impurity of a drug substance as genotoxic means that the "threshold of toxicological concern" (TTC) value of 1.5 μg/day intake, considered to be associated with an acceptable risk, should be the admissible limit in the raw material and that leads to new analytical challenges. In this study, reliable chromatographic methods were developed and applied as limit tests for the control of three genotoxic impurities (GTIs) in cloperastine fendizoate, drug widely used as an antitussive active pharmaceutical ingredient (API). In particular, GC-MS was applied to the determination of one alkyl halide (2-chloroethanol, 2-CE), while HPLC-DAD was selected for the analysis of two sulfonate esters (methyl p-toluenesulfonate, MPTS, and 2-chloroethyl p-toluenesulfonate, CEPTS). Regarding GC-MS, strong anion-exchange (SAX)-SPE was applied to remove fendizoate from the sample solutions, due its low volatility and its high amount in the raw material. The GC-MS analysis was performed on a Factor Four VF-23 ms capillary column (30 m × 0.25 mm I.D., film thickness 0.25 μm, Varian). Single ion-monitoring (SIM) detection mode was set at m/z 80. In the case of HPLC-DAD, a suitable optimization of the chromatographic conditions was carried out in order to obtain a good separation of the impurity peaks from the drug substance peaks. The optimized method utilizes a SymmetryShield RP(8) column (250 mm × 4.6 mm, 5 μm, Waters) kept at 50°C, with phosphate buffer (pH 3.0; 10 mM)-methanol (containing 10% ACN) (45:55, v/v) as the mobile phase, at the flow-rate of 1.7 mL/min and UV detection at 227 nm. The required sensitivity level was achieved by injecting 80 μL of sample solution, purified from fendizoate by SAX-SPE, followed by a 1:1 (v/v) dilution of the SPE eluate with water. For both GC-MS and HPLC-DAD, the method validation was performed in relation to specificity and limit of detection (LOD), as required by ICH guidelines in relation to limit assays. The developed methods were successfully applied for the determination of GTIs in five different batches of cloperastine fendizoate. In all the analyzed batches, the three target GTIs were below the concentration limit. Copyright © 2012 Elsevier B.V. All rights reserved.
Parastar, Hadi; Radović, Jagoš R; Bayona, Josep M; Tauler, Roma
2013-07-01
Multivariate curve resolution-alternating least squares (MCR-ALS) analysis is proposed to solve chromatographic challenges during two-dimensional gas chromatography-time-of-flight mass spectrometry (GC × GC-TOFMS) analysis of complex samples, such as crude oil extract. In view of the fact that the MCR-ALS method is based on the fulfillment of the bilinear model assumption, three-way and four-way GC × GC-TOFMS data are preferably arranged in a column-wise superaugmented data matrix in which mass-to-charge ratios (m/z) are in its columns and the elution times in the second and first chromatographic columns are in its rows. Since m/z values are common for all measured spectra in all second-column modulations, unavoidable chromatographic challenges such as retention time shifts within and between GC × GC-TOFMS experiments are properly handled. In addition, baseline/background contributions can be modeled by adding extra components to the MCR-ALS model. Another outstanding aspect of MCR-ALS analysis is its extreme flexibility to consider all samples (standards, unknowns, and replicates) in a single superaugmented data matrix, allowing joint analysis. In this way, resolution, identification, and quantification results can be simultaneously obtained in a very fast and reliable way. The potential of MCR-ALS analysis is demonstrated in GC × GC-TOFMS analysis of a North Sea crude oil extract sample with relative errors in estimated concentrations of target compounds below 6.0 % and relative standard deviations lower than 7.0 %. The results obtained, along with reasonable values for the lack of fit of the MCR-ALS model and high values of the reversed match factor in mass spectra similarity searches, confirm the reliability of the proposed strategy for GC × GC-TOFMS data analysis.
[Determination of lambda-cyhalothrin residue tea and soil using gas chromatography].
Chen, Linglong; Chen, Jiuxing; Ma, Ming; Chen, Lihua; Yang, Hui; Zhang, Guiqun
2010-08-01
A gas chromatographic (GC) method was established for the determination of lambda-cyhalothrin residue in tea and soil. Tea and soil samples were extracted with hexane, separated by capillary column and determined by gas chromatography-electron capture detector (GC-ECD). The average recoveries of lambda-cyhalothrin in tea and soil were 89.0% - 94.1% and 89.8% - 94.7%, respectively at the spiking levels of 0.02 to 2.00 mg/kg. The corresponding relative standard deviations (RSDs, n = 5) were 3.0% -4.9% and 2.5% -4.2%, respectively. The limit of detection (S/N = 3) was 0.002 mg/kg for lambda-cyhalothrin. The degradations of 2.5% lambda-cyhalothrin microemulsion in tea and soil in Changsha, Hunan were investigated and the degradation equations were Y = 3.199 6e(-0.339 4x) and Y = 0.122 4e(-0.103 6x) with the correlation coefficients of 0.995 6 and 0.924 7, respectively. The half-lives of lambda-cyhalothrin in tea and soil were 2.04 days and 6.69 days, respectively.
Libong, Danielle; Bouchonnet, Stéphane; Ricordel, Ivan
2003-01-01
A gas chromatography-ion trap tandem mass spectrometry (GC-ion trap MS-MS) method for detection and quantitation of LSD in whole blood is presented. The sample preparation process, including a solid-phase extraction step with Bond Elut cartridges, was performed with 2 mL of whole blood. Eight microliters of the purified extract was injected with a cold on-column injection method. Positive chemical ionization was performed using acetonitrile as reagent gas; LSD was detected in the MS-MS mode. The chromatograms obtained from blood extracts showed the great selectivity of the method. GC-MS quantitation was performed using lysergic acid methylpropylamide as the internal standard. The response of the MS was linear for concentrations ranging from 0.02 ng/mL (detection threshold) to 10.0 ng/mL. Several parameters such as the choice of the capillary column, the choice of the internal standard and that of the ionization mode (positive CI vs. EI) were rationalized. Decomposition pathways under both ionization modes were studied. Within-day and between-day stability were evaluated.
Chen, Guowen; Li, Wenjie; Zhang, Chen; Zhou, Chuanjian; Feng, Shengyu
2012-09-21
Phenyl-ended hyperbranched carbosilane (HBC) is synthesized and immobilized onto the inner wall of a fused silica capillary column using a sol-gel process. The hybrid coating layer formed is used as a stationary phase for gas chromatography (GC) and as an adsorption medium for solid phase microextraction (SPME). Trifluoroacetic acid, as a catalyst in this process, helps produce a homogeneous hybrid coating layer. This result is beneficial for better column chromatographic performances, such as high efficiency and high resolution. Extraction tests using the novel hybrid layer show an extraordinarily large adsorption capacity and specific adsorption behavior for aromatic compounds. A 1 ppm trace level detectability is obtained with the SPME/GC work model when both of the stationary phase and adsorption layer bear a hyperbranched structure. A large amount of phenyl groups and a low viscosity of hyperbranched polymers contribute to these valuable properties, which are important to environment and safety control, wherein detection sensitivity and special adsorption behavior are usually required. Copyright © 2012 Elsevier B.V. All rights reserved.
Ashrafi, Behnam; Ramak, Parvin; Ezatpour, Behrouz; Talei, Gholam Reza
2017-01-01
Dracocephalum kotschyi Boiss is a herb with wide-spread applications. Lorestan traditional healers have applied it for the treatment of rheumatoid diseases and stomach disorders. Hydrodistillation process was used for essential oil extraction, the extracted essential oil was then analyzed through combination of capillary GC-FID, GC-MS and RI. The in vitro antimicrobial, antioxidant and cytotoxic activities of this essential oil were examined. Results indicate that the essential oil has a broad range of anti-microbial activity against all of the tested microorganisms. The 50% of cytotoxic concentrations was 26.4 μg/ml and 4266.7 μg/ml for Hela cells and human lymphocytes, respectively. The oil cytotoxicity against the human tumor cell line was far higher than the amount required for human healthy cells. Conversely, the essential oil's IC 50 value of 49.2 μg/ml in the DPPH assay, could be regarded as its strong antioxidant potential. According to the data obtained, it can be concluded that D. kotschyi essential oil could be applied as a safe antibacterial and antioxidant agent for food and pharmaceutical purposes.
Toxicity of plant extracts containing pyrrolizidine alkaloids using alternative invertebrate models
Seremet, Oana Cristina; Olaru, Octavian Tudorel; Gutu, Claudia Maria; Nitulescu, George Mihai; Ilie, Mihaela; Negres, Simona; Zbarcea, Cristina Elena; Purdel, Carmen Nicoleta; Spandidos, Demetrios A.; Tsatsakis, Aristides M.; Coleman, Michael D.; Margina, Denisa Marilena
2018-01-01
Pyrrolizidine alkaloids (PAs) are a widespread class of hepatotoxic heterocyclic organic compounds found in approximately 3% of world flora. Some PAs have been shown to have genotoxic and carcinogenic effects. The present study focuses on the toxicity effects of four dry extracts obtained from medicinal plants (Senecio vernalis, Symphytum officinale, Petasites hybridus and Tussilago farfara), on two aquatic organisms, Artemia salina and Daphnia magna, and the correlation with their PAs content. A new GC-MS method, using a retention time (TR)-5MS type capillary column was developed. PAs Kovats retention indices, for this type of column were computed for the first time. The lethal dose 50% (LC50) values for the two invertebrate models were correlated (Pearson's coefficient, >0.9) and the toxicity was PA concentration-dependent, for three of the four extracts. All tested extracts were found to be toxic in both aquatic organism models. The results can be used to develop a GC-MS validated method for the assay of PAs in medicinal plants with a further potential application in the risk assessment study of PAs toxicity in humans. PMID:29620235
Yang, Xiaohong; Li, Changxia; Qi, Meiling; Qu, Liangti
2016-08-19
This work presents the separation performance of graphene-ZIF8 (G-Z) composite material as stationary phase for capillary gas chromatography (GC). The G-Z stationary phase achieved high column efficiency of 5000 plates/m determined by n-dodecane (k=1.22) at 120°C and showed weakly polar nature. Importantly, it exhibited high selectivity and resolving capability for branched alkane isomers and aromatic positional isomers, showing clear advantages over the reported neat graphene and ZIF8. In addition, it attained high resolution for geometric cis-/trans-isomers. The G-Z column exhibited good column thermal stability up to 300°C and column repeatability with RSD values of retention times in the range of 0.01-0.19% for intra-day, 0.05-0.88% for inter-day and 0.66-5.6% for between-column, respectively, Moreover, the G-Z column was employed for the determination of minor impurity isomers in real reagent samples, which demonstrates its promising potential in GC applications. Copyright © 2016 Elsevier B.V. All rights reserved.
CE-microreactor-CE-MS/MS for protein analysis
Schoenherr, Regine M.; Ye, Mingliang; Vannatta, Michael
2008-01-01
We present a proof-of-principle for a fully automated bottom-up approach to protein characterization. Proteins are first separated by capillary electrophoresis. A pepsin microreactor is incorporated into the distal end of this capillary. Peptides formed in the reactor are transferred to a second capillary, where they are separated by capillary electrophoresis and characterized by mass spectrometry. While peptides generated from one digestion are being separated in the second capillary, the next protein fraction undergoes digestion in the microreactor. The migration time in the first dimension capillary is characteristic of the protein while migration time in the second dimension is characteristic of the peptide. Spot capacity for the two-dimensional separation is 590. A MS/MS analysis of a mixture of cytochrome C and myoglobin generated Mascot MOWSE scores of 107 for cytochrome C and 58 for myoglobin. The sequence coverages were 48% and 22%, respectively. PMID:17295444
Statistical intensity variation analysis for rapid volumetric imaging of capillary network flux
Lee, Jonghwan; Jiang, James Y.; Wu, Weicheng; Lesage, Frederic; Boas, David A.
2014-01-01
We present a novel optical coherence tomography (OCT)-based technique for rapid volumetric imaging of red blood cell (RBC) flux in capillary networks. Previously we reported that OCT can capture individual RBC passage within a capillary, where the OCT intensity signal at a voxel fluctuates when an RBC passes the voxel. Based on this finding, we defined a metric of statistical intensity variation (SIV) and validated that the mean SIV is proportional to the RBC flux [RBC/s] through simulations and measurements. From rapidly scanned volume data, we used Hessian matrix analysis to vectorize a segment path of each capillary and estimate its flux from the mean of the SIVs gathered along the path. Repeating this process led to a 3D flux map of the capillary network. The present technique enabled us to trace the RBC flux changes over hundreds of capillaries with a temporal resolution of ~1 s during functional activation. PMID:24761298
Fazal, Md Abul; Palmer, Vanessa R; Dovichi, Norman J
2006-10-20
Differential detergent fractionation was used to sequentially extract cytosolic, membrane, nuclear, and cytoskeletal fractions from AtT-20 cells. Extracted components were denatured by sodium dodecyl sulfate (SDS) and then labeled with the fluorogenic reagent 3-(2-furoyl) quinoline-1-carboxaldehyde. Both capillary sieving electrophoresis (CSE) and micellar electrokinetic capillary chromatography (MECC) were used to separate labeled components by one-dimensional (1D) electrophoresis. Labeled components were also separated by two-dimensional (2D) capillary electrophoresis; CSE was employed in the first dimension and MECC in the second dimension. Roughly 150 fractions were transferred from the first to the second capillary for this comprehensive analysis in 2.5 h.
Hong, Bo; Li, Wenjing; Song, Aihua; Zhao, Chunjie
2013-01-01
Rauvolfia verticillata (Lour.) Baill. (also called Luofumu in Chinese) is commonly used in traditional Chinese medicine for lowering blood pressure. In this study, a high-performance liquid chromatography assay using ultraviolet detection is described for the simultaneous measurement of the five bioactive indole alkaloids (sarpagine, yohimbine, ajmaline, ajmalicine and reserpine) in Rauvolfia. The detection of all five compounds was conducted at 280 nm. In quantitative analysis, the five compounds showed good regressions (R(2) > 0.9988) within the test ranges, and the recovery of the method was in the range of 90.4-101.4%. In addition, a simple gas chromatography mass method using a DB-1 silica capillary column (30 m × 0.25 mm i.d., 0.25 µm) is described for the identification of the highly volatile compounds in Rauvolfia. In qualitative analysis, more than 39 compounds were assayed and identified using the mass function and the National Institute of Standards and Technology database search system. The results demonstrated that the combination of quantitative and qualitative analyses offered an efficient way to evaluate the quality and consistency of Rauvolfia verticillata.
Semi-automatic assessment of skin capillary density: proof of principle and validation.
Gronenschild, E H B M; Muris, D M J; Schram, M T; Karaca, U; Stehouwer, C D A; Houben, A J H M
2013-11-01
Skin capillary density and recruitment have been proven to be relevant measures of microvascular function. Unfortunately, the assessment of skin capillary density from movie files is very time-consuming, since this is done manually. This impedes the use of this technique in large-scale studies. We aimed to develop a (semi-) automated assessment of skin capillary density. CapiAna (Capillary Analysis) is a newly developed semi-automatic image analysis application. The technique involves four steps: 1) movement correction, 2) selection of the frame range and positioning of the region of interest (ROI), 3) automatic detection of capillaries, and 4) manual correction of detected capillaries. To gain insight into the performance of the technique, skin capillary density was measured in twenty participants (ten women; mean age 56.2 [42-72] years). To investigate the agreement between CapiAna and the classic manual counting procedure, we used weighted Deming regression and Bland-Altman analyses. In addition, intra- and inter-observer coefficients of variation (CVs), and differences in analysis time were assessed. We found a good agreement between CapiAna and the classic manual method, with a Pearson's correlation coefficient (r) of 0.95 (P<0.001) and a Deming regression coefficient of 1.01 (95%CI: 0.91; 1.10). In addition, we found no significant differences between the two methods, with an intercept of the Deming regression of 1.75 (-6.04; 9.54), while the Bland-Altman analysis showed a mean difference (bias) of 2.0 (-13.5; 18.4) capillaries/mm(2). The intra- and inter-observer CVs of CapiAna were 2.5% and 5.6% respectively, while for the classic manual counting procedure these were 3.2% and 7.2%, respectively. Finally, the analysis time for CapiAna ranged between 25 and 35min versus 80 and 95min for the manual counting procedure. We have developed a semi-automatic image analysis application (CapiAna) for the assessment of skin capillary density, which agrees well with the classic manual counting procedure, is time-saving, and has a better reproducibility as compared to the classic manual counting procedure. As a result, the use of skin capillaroscopy is feasible in large-scale studies, which importantly extends the possibilities to perform microcirculation research in humans. © 2013.
Hurst, Harrell E; Ali, Md Yeakub
2007-03-20
Chloroprene (2-chloro-1,3-butadiene, CAS 126-99-8, CP) is a colorless volatile liquid used in manufacture of polychloroprene, a synthetic rubber polymer. National Toxicology Program inhalation studies of CP in rats and mice gave clear evidence of carcinogenic activity. CP is metabolized by CYP2E1 to electrophilic epoxides, including R- and S-(1-chloroethenyl)oxirane (CEO), which form adducts with nucleic acids and other nucleophiles including glutathione and hemoglobin. As detection of these epoxide metabolites in vivo is technically challenging, measurements of CEO-Hb adducts may provide biomarkers of exposure to bioactivated metabolites of CP. The present studies involved exposure of C57BL/6 mouse erythrocytes (RBC) in vitro to pure enantiomers of CEO. Headspace analysis of CEO using Cyclodex-B capillary GC/MS with selected ion monitoring enabled separation, specific detection, and quantification of CEO enantiomers as reactions proceeded in vitro with RBC. These analyses indicated that R-CEO was much more persistent when incubated in vitro with RBC, while S-CEO disappeared rapidly. After periods of exposure of RBC to various concentrations of R- or S-CEO, erythrocytes were lysed and globin isolated. Covalent adducts, formed by reaction of CEO with N-terminal valine in Hb, were analyzed following Edman cleavage and trimethylsilylation. SIM-GC/MS analyses using a 5%-phenyl-dimethylsiloxane capillary column enabled quantification of CEO-Hb adducts. These analyses produced two chromatographic peaks of CEO-valine adduct derivatives, which were tentatively identified from mass spectra, reaction, and abundance data to be 1-(3-chloro-2-trimethylsilyloxybut-3-en-1-yl)-5-isopropyl-3-phenyl-2-thiohydantoin and 1-[2-chloro-1-(trimethylsilyloxymethyl)prop-2-en-1-yl]-5-isopropyl-3-phenyl-2-thiohydantoin. Analyses quantified significantly greater levels of adducts formed from R-CEO than from S-CEO. Studies involving pretreatment of RBC with glutathione-depleting diethyl maleate diminished the selective detoxification of S-CEO, and suggest enantiomeric selectivity of mouse glutathione-S-transferase as a mechanism of differential detoxification of CEO enantiomers. These results indicate more rapid detoxification of S-CEO by mouse RBC in vitro, while R-CEO may persist to react with cellular nucleophiles.
Kim, Sung-Jin; Reidy, Shaelah M; Block, Bruce P; Wise, Kensall D; Zellers, Edward T; Kurabayashi, Katsuo
2010-07-07
In comprehensive two-dimensional gas chromatography (GC x GC), a modulator is placed at the juncture between two separation columns to focus and re-inject eluting mixture components, thereby enhancing the resolution and the selectivity of analytes. As part of an effort to develop a microGC x microGC prototype, in this report we present the design, fabrication, thermal operation, and initial testing of a two-stage microscale thermal modulator (microTM). The microTM contains two sequential serpentine Pyrex-on-Si microchannels (stages) that cryogenically trap analytes eluting from the first-dimension column and thermally inject them into the second-dimension column in a rapid, programmable manner. For each modulation cycle (typically 5 s for cooling with refrigeration work of 200 J and 100 ms for heating at 10 W), the microTM is kept approximately at -50 degrees C by a solid-state thermoelectric cooling unit placed within a few tens of micrometres of the device, and heated to 250 degrees C at 2800 degrees C s(-1) by integrated resistive microheaters and then cooled back to -50 degrees C at 250 degrees C s(-1). Thermal crosstalk between the two stages is less than 9%. A lumped heat transfer model is used to analyze the device design with respect to the rates of heating and cooling, power dissipation, and inter-stage thermal crosstalk as a function of Pyrex-membrane thickness, air-gap depth, and stage separation distance. Experimental results are in agreement with trends predicted by the model. Preliminary tests using a conventional capillary column interfaced to the microTM demonstrate the capability for enhanced sensitivity and resolution as well as the modulation of a mixture of alkanes.
Capillary electrophoresis: principles and applications in illicit drug analysis.
Tagliaro, F; Turrina, S; Smith, F P
1996-02-09
Capillary electrophoresis, which appeared in the early 1980s, is now rapidly expanding into many scientific disciplines, including analytical chemistry, biotechnology and biomedical and pharmaceutical sciences. In capillary electrophoresis,electrokinetic separations are carried out in tiny capillaries at high voltages (10-30 kV), thus obtaining high efficiencies (N > 10(5)) and excellent mass sensitivities (down to 10(-18)-10(-20) moles). The main features of capillary electrophoresis are: versatility of application (from inorganic ions to large DNA fragments), use of different separation modes with different selectivity, extremely low demands on sample volume, negligible running costs, possibility of interfacing with different detection systems, ruggedness and simplicity of instrumentation. Capillary electrophoresis applications in forensic sciences have appeared only recently, but are now rapidly growing, particularly in forensic toxicology. The present paper briefly describes the basic principles of capillary electrophoresis, from both the instrumental and analytical points of view. Furthermore, the main applications in the analysis of illicit/controlled drugs in both illicit preparations and biological samples are presented and discussed (43 references). It is concluded that the particular separation mechanism and the high complementarity of this technique to chromatography makes capillary electrophoresis a new powerful tool of investigation in the hands of forensic toxicologists.
[Structure of newly formed capillaries of the rabbit cornea (electron microscopic study)].
Gurina, O Iu; Karaganov, Ia L
1984-08-01
Owing to a complex application of topical analysis and tracer technique, it is possible to carry out a light optic and electron microscopic investigation of newly formed capillaries growing in the rabbit cornea after its chemical burn. The ultrastructural analysis demonstrates certain polymorphism of morphological organization of endotheliocyte in the newly formed capillaries. There is a rather elevated amount of free ribosomes, mitochondria, microtubules and microfilaments in cytoplasm. The granular endoplasmic reticulum and Golgi complex are hypertrophied. Weibel--Palade bodies appear. Taking into account certain morpho-functional peculiarities of endothelial cells along the course of the growing capillaries, on the 8th day of growth three zone are distinguished: 1--area of nondifferentiated endothelium (apex of the capillary), 2--transitional zone, 3--zone of relatively differentiated endothelium situating in the place where the capillary gets off the parental vessel. According to the zones distinguished, the ways of trans-endothelial transport of molecules are investigated. In formation of the capillary barrier-transport function an important role belongs to polymorphism of the endothelial cells along the course of the growing capillary which is determined by differentiation degree of these cells depending on their participation in permeability.
Darwin; WipaCharles; Cord-Ruwisch, Ralf
2018-01-01
Organic acid analysis of fermentation samples can be readily achieved by gas chromatography (GC), which detects volatile organic acids. However, lactic acid, a key fermentation acid is non-volatile and can hence not be quantified by regular GC analysis. However the addition of periodic acid to organic acid samples has been shown to enable lactic acid analysis by GC, as periodic acid oxidizes lactic acid to the volatile acetaldehyde. Direct GC injection of lactic acid standards and periodic acid generated inconsistent and irreproducible peaks, possibly due to incomplete lactic acid oxidation to acetaldehyde. The described method is developed to improve lactic acid analysis by GC by using a heat treated derivatization pre-treatment, such that it becomes independent of the retention time and temperature selection of the GC injector. Samples containing lactic acid were amended by periodic acid and heated in a sealed test tube at 100°C for at least 45 min before injecting it to the GC. Reproducible and consistent peaks of acetaldehyde were obtained. Simultaneous determination of lactic acid, acetone, ethanol, butanol, volatile fatty acids could also be accomplished by applying this GC method, enabling precise and convenient organic acid analysis of biological samples such as anaerobic digestion and fermentation processes. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Molodovskaya, M. S.; Svensson, T.; Pitts, A.; Delmonte, J.; Nesic, Z.; Oberg, G.
2010-12-01
The volatile organic chlorinated compounds (VOCl) are important components of the global chlorine budget. The origin of VOCl in the environment was for decades thought to be strictly anthropogenic. Over the past decade, a number of studies have however shown that VOCls are naturally formed in soil, and nowadays this source is recognized as a crucial part of the global biogeochemical chlorine cycle. The relative contribution of soil VOCl to the global chlorine cycle is however unclear, a key reason being that monitoring of soil VOCl is complicated by low concentrations and high variability of emission rates. Static chamber deployments coupled with canister gas sampling and gas chromatography (GC) analysis is the most commonly used method for quantifying VOCl emissions. Static chambers are however of limited use for estimating larger scale fluxes since the method is highly labor intensive (leading low sampling frequency). The poor data resolution resulting from these limitations can strongly bias the data extrapolation. Here, we report a method that would allow more continuous and precise VOCl flux measurements. The study has been carried out in a forest in British Columbia, Canada, using automated dynamic chambers and advanced GC technique. The chamber setup is based on a design that previously has been employed and proven successful for carbon dioxide and soil respiration measurements. The method includes a collar permanently inserted into the ground and an attached dome-shaped cover. The air from the closed chamber is pumped through the on-site sampling device. The cover opens and closes automatically between deployments (40 min in average), which helps to minimize the chamber supervision and obtain more continuous data. Soil VOCl concentrations are commonly at the ppt-level, much lower than atmospheric carbon dioxide, so necessary adjustments were made to the chamber system to pre-concentrate the compounds of interest. During each deployment, soil air from the automated chamber was continuously pumped through the glass tubes filled with carbon-based absorbent (Carbotrap 300) to capture and retain VOCl. At the end of each measurement period, the tubes are brought back to the lab, and the content is analyzed by Agilent 7890 GC/micro-ECD coupled with the Gerstel Thermal Desorption System (TDS) and Cooled Injection System (CIS). The ultra sensitive micro-ECD detection and high-efficiency capillary column (Rtx®-VMS, 20m x 0.18mm ID x 1.0µm) allows rapid separation and quantification of the mid-weight VOCl such as chloroform, carbon tetrachloride, 1,1,1-trichloroethane and bromochloromethane. The GC-method dynamic range is linear within 0.1-200.0ng, and the analytical precision is determined to be 4%. The described system can be used for the analysis of soil/atmosphere exchange of VOCl at the detection limit of 1.9ng m-2 h-1, which is far below previously reported average soil emission levels from forest soils. The high precision GC analysis combined with the automatic chambers makes it possible to study the high spatial and temporal variability of soil VOCl fluxes.
Noriega, Mary C.; Wydoski, Duane S.; Foreman, William T.
2004-01-01
A method applicable for the determination of 19 organochlorine (OC) pesticides, including total toxaphene as a complex mixture, and 3 polychlorinated biphenyl (PCB) mixtures as Aroclor equivalents--Aroclor 1016/1242, 1254, and 1260--in soil, aquatic bottom sediment, and suspended sediment is described. Method performance data are presented. The solvent system is designed to extract simultaneously selected OC pesticides and PCBs from the same sample matrix. The compounds are extracted by conventional Soxhlet extraction with dichloromethane, followed by partial isolation using gel permeation chromatography (GPC) to remove inorganic sulfur and large naturally present molecules from the sediment extract. The aliquot of extract collected from the GPC for OCs (OC pesticides and PCBs) is split into two sample fractions by alumina/silica combined-column chromatography, followed by Florisil adsorption chromatography to remove interfering compounds in the second fraction. The OC fractions are analyzed by dual capillary-column gas chromatography with electron-capture detection (GC/ECD). This report is limited to the determination of selected OC pesticides and PCBs by GC/ECD using this method. Interim reporting levels (IRLs) have been set at 0.400 to 3.12 micrograms per kilogram for 18 individual OC pesticides, 200 micrograms per kilogram for toxaphene, and 4.04 to 4.68 micrograms per kilogram for the PCBs, based on a sample size of 25-gram equivalent dry weight. These reporting levels may change following additional determinations of method detection limits.
[Comparative GC analysis of essential oil in imported sandalwood].
Wang, Z; Hong, X
1991-01-01
The GC-fingerprint spectra of essential oils in imported sandalwood are established by the new technique of GC-relative retention value fingerprint spectrum (GC-FPS). According to the GC-FPS of samples, their chromatographic peaks, overlap ratio of peaks and eight strong peaks are studied comparatively.
Analysis of 62 synthetic cannabinoids by gas chromatography-mass spectrometry with photoionization.
Akutsu, Mamoru; Sugie, Ken-Ichi; Saito, Koichi
2017-01-01
Gas chromatography-mass spectrometry (GC-MS) in electron ionization (EI) mode is one of the most commonly used techniques for analysis of synthetic cannabinoids, because the GC-EI-MS spectra contain characteristic fragment ions for identification of a compound; however, the information on its molecular ions is frequently lacking. To obtain such molecular ion information, GC-MS in chemical ionization (CI) mode is frequently used. However, GC-CI-MS requires a relatively tedious process using reagent gas such as methane or isobutane. In this study, we show that GC-MS in photoionization (PI) mode provided molecular ions in all spectra of 62 synthetic cannabinoids, and 35 of the 62 compounds showed only the molecular radical cations. Except for the 35 compounds, the PI spectra showed very simple patterns with the molecular peak plus only a few fragment peak(s). An advantage is that the ion source for GC-PI-MS can easily be used for GC-EI-MS as well. Therefore, GC-EI/PI-MS will be a useful tool for the identification of synthetic cannabinoids contained in a dubious product. To the best of our knowledge, this is the first report to use GC-PI-MS for analysis of synthetic cannabinoids.
Field-Scale Modeling of Local Capillary Trapping During CO2 Injection into a Saline Aquifer
NASA Astrophysics Data System (ADS)
Ren, B.; Lake, L. W.; Bryant, S. L.
2015-12-01
Local capillary trapping is the small-scale (10-2 to 10+1 m) CO2 trapping that is caused by the capillary pressure heterogeneity. The benefit of LCT, applied specially to CO2 sequestration, is that saturation of stored CO2 is larger than the residual gas, yet these CO2 are not susceptible to leakage through failed seals. Thus quantifying the extent of local capillary trapping is valuable in design and risk assessment of geologic storage projects. Modeling local capillary trapping is computationally expensive and may even be intractable using a conventional reservoir simulator. In this paper, we propose a novel method to model local capillary trapping by combining geologic criteria and connectivity analysis. The connectivity analysis originally developed for characterizing well-to-reservoir connectivity is adapted to this problem by means of a newly defined edge weight property between neighboring grid blocks, which accounts for the multiphase flow properties, injection rate, and gravity effect. Then the connectivity is estimated from shortest path algorithm to predict the CO2 migration behavior and plume shape during injection. A geologic criteria algorithm is developed to estimate the potential local capillary traps based only on the entry capillary pressure field. The latter is correlated to a geostatistical realization of permeability field. The extended connectivity analysis shows a good match of CO2 plume computed by the full-physics simulation. We then incorporate it into the geologic algorithm to quantify the amount of LCT structures identified within the entry capillary pressure field that can be filled during CO2 injection. Several simulations are conducted in the reservoirs with different level of heterogeneity (measured by the Dykstra-Parsons coefficient) under various injection scenarios. We find that there exists a threshold Dykstra-Parsons coefficient, below which low injection rate gives rise to more LCT; whereas higher injection rate increases LCT in heterogeneous reservoirs. Both the geologic algorithm and connectivity analysis are very fast; therefore, the integrated methodology can be used as a quick tool to estimate local capillary trapping. It can also be used as a potential complement to the full-physics simulation to evaluate safe storage capacity.
Burtis, Carl A.; Johnson, Wayne F.; Walker, William A.
1988-01-01
A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises (1) a whole blood sample disc, (2) a serum sample disc, (3) a sample preparation rotor, and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc in capillary tubes filled by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analytical rotor for analysis by conventional methods.
Huang, Xuan-Zhang; Chen, You; Wu, Jian; Zhang, Xi; Wu, Cong-Cong; Zhang, Chao-Ying; Sun, Shuang-Shuang; Chen, Wen-Jun
2017-01-17
The association between non-steroidal anti-inflammatory drugs (NSAIDs) and gastric cancer (GC) risk is controversial. The aim of this study is to evaluate the chemopreventive effect of NSAIDs for GC. A literature search was performed for relevant studies using the PubMed and Embase database (up to March 2016). Risk ratios (RRs) and 95% confidence intervals (CIs) were used as the effect measures. The dose-response analysis and subgroup analysis were also performed. Twenty-four studies were included. Our results indicated that NSAIDs could reduce GC risk (any NSAIDs: RR=0.78, 96%CI=0.72-0.85; aspirin: RR=0.70, 95%CI=0.62-0.80; non-aspirin NSAIDs: RR=0.86, 95%CI=0.80-0.94), especially for non-cardia GC risk. Moreover, the dose-response analysis indicated the risk of GC decreased by 11% and 5% for 2 years increment of any NSAIDs and aspirin use, respectively. There were nonlinear relationships between the frequency of any NSAIDs use and aspirin use and GC risk (P for non-linearity<0.01), with a threshold effect of 5 times/week. A monotonically decreasing trend was observed only for the frequency of less than 5 times/week. Our results indicate that NSAIDs is inversely associated with GC risk, especially for non-cardia GC risk. NSAIDs use may become a feasible approach to prevent GC.
Causal inference in nonlinear systems: Granger causality versus time-delayed mutual information
NASA Astrophysics Data System (ADS)
Li, Songting; Xiao, Yanyang; Zhou, Douglas; Cai, David
2018-05-01
The Granger causality (GC) analysis has been extensively applied to infer causal interactions in dynamical systems arising from economy and finance, physics, bioinformatics, neuroscience, social science, and many other fields. In the presence of potential nonlinearity in these systems, the validity of the GC analysis in general is questionable. To illustrate this, here we first construct minimal nonlinear systems and show that the GC analysis fails to infer causal relations in these systems—it gives rise to all types of incorrect causal directions. In contrast, we show that the time-delayed mutual information (TDMI) analysis is able to successfully identify the direction of interactions underlying these nonlinear systems. We then apply both methods to neuroscience data collected from experiments and demonstrate that the TDMI analysis but not the GC analysis can identify the direction of interactions among neuronal signals. Our work exemplifies inference hazards in the GC analysis in nonlinear systems and suggests that the TDMI analysis can be an appropriate tool in such a case.
Recent advances in capillary ultrahigh pressure liquid chromatography.
Blue, Laura E; Franklin, Edward G; Godinho, Justin M; Grinias, James P; Grinias, Kaitlin M; Lunn, Daniel B; Moore, Stephanie M
2017-11-10
In the twenty years since its initial demonstration, capillary ultrahigh pressure liquid chromatography (UHPLC) has proven to be one of most powerful separation techniques for the analysis of complex mixtures. This review focuses on the most recent advances made since 2010 towards increasing the performance of such separations. Improvements in capillary column preparation techniques that have led to columns with unprecedented performance are described. New stationary phases and phase supports that have been reported over the past decade are detailed, with a focus on their use in capillary formats. A discussion on the instrument developments that have been required to ensure that extra-column effects do not diminish the intrinsic efficiency of these columns during analysis is also included. Finally, the impact of these capillary UHPLC topics on the field of proteomics and ways in which capillary UHPLC may continue to be applied to the separation of complex samples are addressed. Copyright © 2017 Elsevier B.V. All rights reserved.
Liu, Shaorong; Gao, Lin; Pu, Qiaosheng; Lu, Joann J; Wang, Xingjia
2006-02-01
We have recently developed a new process to create cross-linked polyacrylamide (CPA) coatings on capillary walls to suppress protein-wall interactions. Here, we demonstrate CPA-coated capillaries for high-efficiency (>2 x 10(6) plates per meter) protein separations by capillary zone electrophoresis (CZE). Because CPA virtually eliminates electroosmotic flow, positive and negative proteins cannot be analyzed in a single run. A "one-sample-two-separation" approach is developed to achieve a comprehensive protein analysis. High throughput is achieved through a multiplexed CZE system.
The purpose of this SOP is to describe the methods used for detection and quantification by gas chromatography/mass spectrometry (GC/MS) of pesticides in a variety of matrices, including air, house dust, soil, and handwipes. This analysis involves automated gas GC/MS analysis us...
Mondello, Luigi; Casilli, Alessandro; Tranchida, Peter Quinto; Lo Presti, Maria; Dugo, Paola; Dugo, Giovanni
2007-11-01
The present research is focused on the development of a comprehensive two-dimensional gas chromatography-rapid scanning quadrupole mass spectrometric (GC x GC-qMS) methodology for the analysis of trace-amount pesticides contained in a complex real-world sample. Reliable peak assignment was carried out by using a recently developed, dedicated pesticide MS library (for comprehensive GC analysis), characterized by a twin-filter search procedure, the first based on a minimum degree of spectral similarity and the second on the interactive use of linear retention indices (LRI). The library was constructed by subjecting mixtures of commonly used pesticides to GC x GC-qMS analysis and then deriving their pure mass spectra and LRI values. In order to verify the effectiveness of the approach, a pesticide-contaminated red grapefruit extract was analysed. The certainty of peak assignment was attained by exploiting both the enhanced separation power of dual-oven GC x GC and the highly effective search procedure.
Ramírez, Jorge; Gilardoni, Gianluca; Jácome, Miriam; Montesinos, José; Rodolfi, Marinella; Guglielminetti, Maria Lidia; Cagliero, Cecila; Bicchi, Carlo; Vidari, Giovanni
2017-12-01
This study describes the GC-FID, GC/MS, GC-O, and enantioselective GC analysis of the essential oil hydrodistilled from leaves of Lepechinica mutica (Lamiaceae), collected in Ecuador. GC-FID and GC/MS analyses allowed the characterization and quantification of 79 components, representing 97.3% of the total sample. Sesquiterpene hydrocarbons (38.50%) and monoterpene hydrocarbons (30.59%) were found to be the most abundant volatiles, while oxygenated sesquiterpenes (16.20%) and oxygenated monoterpenes (2.10%) were the minor components. In order to better characterize the oil aroma, the most important odorants, from the sensorial point of view, were identified by Aroma Extract Dilution Analysis (AEDA) GC-O. They were α-Pinene, β-Phellandrene, and Dauca-5,8-diene, exhibiting the characteristic woody, herbaceus, and earthy odors, respectively. Enantioselective GC analysis of L. mutica essential oil revealed the presence of twelve couples and two enantiomerically pure chiral monoterpenoids. Their enantiomeric excesses were from a few percent units to 100%. Moreover, the essential oil exhibited moderate in vitro activity against five fungal strains, being especially effective against M. canis, which is a severe zoophilic dermatophyte causal agent of pet and human infections. © 2017 Wiley-VHCA AG, Zurich, Switzerland.
Analytical methods for determination of mycotoxins: a review.
Turner, Nicholas W; Subrahmanyam, Sreenath; Piletsky, Sergey A
2009-01-26
Mycotoxins are small (MW approximately 700), toxic chemical products formed as secondary metabolites by a few fungal species that readily colonise crops and contaminate them with toxins in the field or after harvest. Ochratoxins and Aflatoxins are mycotoxins of major significance and hence there has been significant research on broad range of analytical and detection techniques that could be useful and practical. Due to the variety of structures of these toxins, it is impossible to use one standard technique for analysis and/or detection. Practical requirements for high-sensitivity analysis and the need for a specialist laboratory setting create challenges for routine analysis. Several existing analytical techniques, which offer flexible and broad-based methods of analysis and in some cases detection, have been discussed in this manuscript. There are a number of methods used, of which many are lab-based, but to our knowledge there seems to be no single technique that stands out above the rest, although analytical liquid chromatography, commonly linked with mass spectroscopy is likely to be popular. This review manuscript discusses (a) sample pre-treatment methods such as liquid-liquid extraction (LLE), supercritical fluid extraction (SFE), solid phase extraction (SPE), (b) separation methods such as (TLC), high performance liquid chromatography (HPLC), gas chromatography (GC), and capillary electrophoresis (CE) and (c) others such as ELISA. Further currents trends, advantages and disadvantages and future prospects of these methods have been discussed.
NASA Astrophysics Data System (ADS)
Kubátová, Alena; Vermeylen, Reinhilde; Claeys, Magda; Cafmeyer, Jan; Maenhaut, Willy; Roberts, Greg; Artaxo, Paulo
High-resolution capillary gas chromatography (GC) and GC/mass spectrometry (MS) were employed for the quantitative determination of dichloromethane-extractable organic compounds in total and size-fractionated aerosol samples which were collected in the Amazon basin, Brazil, during the wet season, as part of the LBA-CLAIRE-98 experiment. Special emphasis was placed on the characterization and identification of several novel unknown dicarboxylic acids and related oxidative degradation products. This class of acidic products was enriched in the fine size fraction, suggesting that they were secondary organic aerosol products formed by gas-to-particle conversion. Some of the unknowns contributed more to the class of dicarboxylic acids than the major known compound, nonadioic acid (azelaic acid). The same unknowns were also observed in urban aerosol samples collected on hot summer days in Gent, Belgium. For the characterization and structure elucidation of the unknowns, various types of derivatizations and fractionation by solid-phase extraction were employed in combination with GC/MS. Four unknowns were identified. The most abundant were two derivatives of glutaric acid, 3-isopropyl pentanedioic acid and 3-acetyl pentanedioic acid. The other two identified unknowns were another oxo homologue, 3-acetyl hexanedioic acid, and, interestingly, 3-carboxy heptanedioic acid. To our knowledge, the occurrence of these four compounds in atmospheric aerosols has not yet been reported. The biogenic precursors of the novel identified compounds could not be pinpointed, but most likely include monoterpenes and fatty acids.
Ceballos, Diana; Zielinska, Barbara; Fujita, Eric; Sagebiel, John
2007-03-01
Gasoline tracers were collected on solid-phase microextraction (SPME) fibers and analyzed by capillary gas chromatography with photoionization detector (GC/PID). This was part of a larger study to quantify personal exposure to motor vehicle gasoline evaporative and combustive emissions in high-end exposure microenvironments (MEs). The SPME fiber selected for this application was a 75-microm carboxen/polydimethylsiloxane. Sequential 10-min samples were collected for measurement of benzene, toluene, ethylbenzene, and ortho-, meta-, and para-xylene in different MEs in Atlanta, GA, in summer 2002 and Reno, NV, in spring 2003. Field calibrations were performed with certified gas standards in 1-L Tedlar bags for varying concentrations and exposure times. SPME detection limits were approximately 0.2 ppbv with a precision of 3-17% and accuracy of 30%. A dynamic system was designed for temperature and relative humidity calibrations, with corrections for the effects of these variables performed when necessary. SPME data compared satisfactorily with integrated canister samples, continuous PID, and field portable mass spectrometer data.
Hu, Wenli; Du, Jiawei
2005-09-01
Indian meal moth Plodia interpunctella Hübner (Lepidoptera: Pyralidae) is considered as an important insect pest infesting stored grains and other products in China. The major sex pheromone component of P. interpunctella, Z9, E12-14: OAc (TDA), has already been identified. Though the efficiency of male capture by using the bait with this component alone is quite good, the pheromone system is far from fully understood. The identification with capillary chromatographic analysis and GC-MS methods showed that there were four main components, i. e., Z9, E12-14: OAc(A), Z9, E12-14: OH (B), Z9, E12-14: Ald(C), and Z9-14: OAc(D), in the sex pheromone gland of female P. interpunctella, and the ratio of these four components was A: B: C:D= 100:22: 12:9. Wind tunnel experimental results suggested that the response of male P. interpunctella to a blend (A: B: C: D = 8:2:1:0.8) was not significantly different from that to female sex pheromone gland extracts.
Du, Li Chuan; Gao, Ru
2017-07-01
In the Chinese population, gastric cancer (GC) is ranked as the third most common type of cancer. Although the exact etiology of GC development is unclear, several factors, including genetic and environmental, have been identified as risk factors. Variations in cytokine genes and their receptors have been related to a higher risk of GC. A single nucleotide polymorphism in the promoter region of tumor necrosis factor-α (TNF-α) (-308G>A) has been associated with a higher risk of GC and in the present study we evaluated its possible association with GC in a Chinese cohort. In addition, we performed a meta-analysis to draw a firm conclusion about the association between TNF-α gene polymorphisms and GC. We enrolled 400 Chinese GC patients and matched healthy controls hailing from similar geographical areas. The TNF-α -308G/A polymorphism was genotyped by allele-specific polymerase chain reaction (AS-PCR). For the meta-analysis, earlier published articles were searched and eligible studies were included. Prevalence of the heterozygous mutant (GA) and minor allele (A) were significantly higher in GC cases compared to healthy controls (GA: p<0.0001, odds ratio (OR)=4.90; A: p<0.0001, OR=2.84). A total of 36 eligible studies including the present report, encompassing of 8353 GC patients and 12099 controls, were analyzed for the meta-analysis. A significant association of the TNF-α polymorphism (-308G>A) with susceptibility to GC was only found in the Caucasian population (A vs G: p=0.001; AA vs GG: p=0.01; AG vs GG: p<0.0001; AA vs AG+GG: p=0.01; AA+AG vs p=0.003). The results of the present case control study and meta-analysis showed that associations between TNF-a variants with susceptibility to GC development is population and ethnic specific.
NASA Astrophysics Data System (ADS)
Bulanov, Stepan; Bagdasarov, Gennadiy; Bobrova, Nadezhda; Boldarev, Alexey; Olkhovskaya, Olga; Sasorov, Pavel; Gasilov, Vladimir; Barber, Samuel; Gonsalves, Anthony; Schroeder, Carl; van Tilborg, Jeroen; Esarey, Eric; Leemans, Wim; Levato, Tadzio; Margarone, Daniele; Korn, Georg; Kando, Masaki; Bulanov, Sergei
2017-10-01
A novel method for asymmetric focusing of electron beams is proposed. The scheme is based on the active lensing technique, which takes advantage of the strong inhomogeneous magnetic field generated inside the capillary discharge plasma to focus the ultrarelativistic electrons. The plasma and magnetic field parameters inside a capillary discharge are described theoretically and modeled with dissipative MHD simulations to enable analysis of capillaries of oblong rectangle cross-sections implying that large aspect ratio rectangular capillaries can be used to form flat electron bunches. The effect of the capillary cross-section on the electron beam focusing properties were studied using the analytical methods and simulation- derived magnetic field map showing the range of the capillary discharge parameters required for producing the high quality flat electron beams.
Oh, Se Yeon; Shin, Hyun Du; Kim, Sung Jean; Hong, Jongki
2008-03-07
A novel analytical method using fast gas chromatography combined with surface acoustic wave sensor (GC/SAW) has been developed for the detection of volatile aroma compounds emanated from lilac blossom (Syringa species: Syringa vulgaris variginata and Syringa dilatata). GC/SAW could detect and quantify various fragrance emitted from lilac blossom, enabling to provide fragrance pattern analysis results. The fragrance pattern analysis could easily characterize the delicate differences in aromas caused by the substantial difference of chemical composition according to different color and shape of petals. Moreover, the method validation of GC/SAW was performed for the purpose of volatile floral actual aroma analysis, achieving a high reproducibility and excellent sensitivity. From the validation results, GC/SAW could serve as an alternative analytical technique for the analysis of volatile floral actual aroma of lilac. In addition, headspace solid-phase microextraction (HS-SPME) GC-MS was employed to further confirm the identification of fragrances emitted from lilac blossom and compared to GC/SAW.
Miller, Andreas; Frenzel, Thomas; Schmarr, Hans-Georg; Engel, Karl-Heinz
2003-01-24
An approach based on on-line coupled liquid chromatography-gas chromatography (LC-GC) was developed for the rapid analysis of gamma-oryzanol in rice. Total lipids were extracted from rice and subjected to LC-GC without any prior purification. gamma-Oryzanol was pre-separated by HPLC from rice lipids and transferred on-line to GC analysis in order to separate its major constituents. 24-methylenecycloartanyl ferulate, cycloartenyl ferulate, campesteryl ferulate, beta-sitosteryl ferulate and campestanyl ferulate. The identities of the compounds were confirmed by off-line GC-MS analysis. Total gamma-oryzanol content could be quantified by HPLC-UV detection and the distribution of gamma-oryzanol constituents could be determined by on-line coupled GC analysis. The proposed methodology paves the way for high-throughput investigations providing information on natural variations in gamma-oryzanol content and its composition in different rice varieties.
Bruggink, C.; Koeleman, C.; Barreto, V.; Lui, Y.; Pohl, C.; Ingendoh, A.; Wuhrer, M.; Hokke, C.; Deelder, A.
2007-01-01
High-pH anion-exchange chromatography with pulsed amperometric detection (HPAEC-PAD) is an established technique for selective separation and analysis of underivatized carbohydrates. The miniaturization of chromatographic techniques by means of capillary columns, and on-line coupling to mass spectrometry are critical to the further development of glycan analysis methods that are compatible with the current requirements in clinical settings. A system has been developed based on the Dionex BioLC equipped with a microbore gradient pump with PEEK flow splitter, a FAMOS micro autosampler, a modified electrochemical cell for on-line capillary PAD, and a capillary column (380 μm i.d.) packed with a new type of anion-exchange resin. This system operates with sensitivity in the low femtomol range. In addition, an on-line capillary desalter has been developed to allow direct coupling to the Bruker Esquire 3000 ion-trap mass spectrometer with electrospray ionization interface (ESI-IT-MS). Both systems have been evaluated using oligosaccharide standards as well as urine samples exhibiting various lysosomal oligosaccharide storage diseases. Initial data indicate that the robust and selective anion-exchange system, in combination with ESI-IT-MS for structure confirmation and analysis, provides a powerful platform that complements existing nano/capillary LC-MS methods for analytical determination of oligosaccharides in biological matrices.
The -765G>C polymorphism in the cyclooxygenase-2 gene and digestive system cancer: a meta-analysis.
Zhao, Fen; Cao, Yue; Zhu, Hong; Huang, Min; Yi, Cheng; Huang, Ying
2014-01-01
Published data regarding associations between the -765G>C polymorphism in cyclooxygenase-2 (COX-2) gene and digestive system cancer risk have been inconclusive. The aim of this study was to comprehensively evaluate the genetic risk of the -765G>C polymorphism in the COX-2 gene for digestive system cancer. A search was performed in Pubmed, Medline (Ovid), Embase, CNKI, Weipu, Wanfang and CBM databases, covering all studies until Feb 10, 2014. Statistical analysis was performed using Revman5.2. A total of 10,814 cases and 16,174 controls in 38 case-control studies were included in this meta-analysis. The results indicated that C allele carriers (GC+CC) had a 20% increased risk of digestive system cancer when compared with the homozygote GG (odds ratio (OR)=1.20, 95% confidence interval (CI), 1.00-1.44 for GC+CC vs GG). In the subgroup analysis by ethnicity, significant elevated risks were associated with C allele carriers (GC+CC) in Asians (OR = 1.46, 95% CI=1.07-2.01, and p=0.02) and Africans (OR=2.12, 95% CI=1.57-2.87, and p< 0.00001), but not among Caucasians, Americans and mixed groups. For subgroup analysis by cancer type (GC+CC vs GG), significant associations were found between the -765G>C polymorphism and higher risk for gastric cancer (OR=1.64, 95% CI=1.03-2.61, and p=0.04), but not for colorectal cancer, oral cancer, esophageal cancer, and others. Regarding study design (GC+CC vs GG), no significant associations were found in then population-based case-control (PCC), hospital-based case-control (HCC) and family-based case-control (FCC) studies. This meta-analysis suggested that the -765G>C polymorphism of the COX-2 gene is a potential risk factor for digestive system cancer in Asians and Africans and gastric cancer overall.
Heuristic approach to capillary pressures averaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Coca, B.P.
1980-10-01
Several methods are available to average capillary pressure curves. Among these are the J-curve and regression equations of the wetting-fluid saturation in porosity and permeability (capillary pressure held constant). While the regression equation seem completely empiric, the J-curve method seems to be theoretically sound due to its expression based on a relation between the average capillary radius and the permeability-porosity ratio. An analysis is given of each of these methods.
ERIC Educational Resources Information Center
Pursell, Christopher J.; Chandler, Bert; Bushey, Michelle M.
2004-01-01
Capillary electrophoresis is gradually working its way into the undergraduate laboratory curriculum. Typically, experiments utilizing this newer technology have been introduced into analytical or instrumental courses. The authors of this article have introduced an experiment into the introductory laboratory that utilizes capillary electrophoresis…
Transcriptomic Analysis and Meta-Analysis of Human Granulosa and Cumulus Cells
Burnik Papler, Tanja; Vrtacnik Bokal, Eda; Maver, Ales; Kopitar, Andreja Natasa; Lovrečić, Luca
2015-01-01
Specific gene expression in oocytes and its surrounding cumulus (CC) and granulosa (GC) cells is needed for successful folliculogenesis and oocyte maturation. The aim of the present study was to compare genome-wide gene expression and biological functions of human GC and CC. Individual GC and CC were derived from 37 women undergoing IVF procedures. Gene expression analysis was performed using microarrays, followed by a meta-analysis. Results were validated using quantitative real-time PCR. There were 6029 differentially expressed genes (q < 10−4); of which 650 genes had a log2 FC ≥ 2. After the meta-analysis there were 3156 genes differentially expressed. Among these there were genes that have previously not been reported in human somatic follicular cells, like prokineticin 2 (PROK2), higher expressed in GC, and pregnancy up-regulated nonubiquitous CaM kinase (PNCK), higher expressed in CC. Pathways like inflammatory response and angiogenesis were enriched in GC, whereas in CC, cell differentiation and multicellular organismal development were among enriched pathways. In conclusion, transcriptomes of GC and CC as well as biological functions, are distinctive for each cell subpopulation. By describing novel genes like PROK2 and PNCK, expressed in GC and CC, we upgraded the existing data on human follicular biology. PMID:26313571
ERIC Educational Resources Information Center
Huang, Shu Rong; Palmer, Peter T.
2017-01-01
This paper describes a method for determination of trihalomethanes (THMs) in drinking water via solid-phase microextraction (SPME) GC/MS as a means to develop and improve student understanding of the use of GC/MS for qualitative and quantitative analysis. In the classroom, students are introduced to SPME, GC/MS instrumentation, and the use of MS…
Balaratnasingam, Chandrakumar; An, Dong; Sakurada, Yoichi; Lee, Cecilia S; Lee, Aaron Y; McAllister, Ian L; Freund, K Bailey; Sarunic, Marinko; Yu, Dao-Yi
2018-05-01
To use the capillary-free zone along retinal arteries, a physiologic area of superficial avascularization, as an anatomic paradigm to investigate the reliability of optical coherence tomography angiography (OCTA) for visualizing the deep retinal circulation. Validity analysis and laboratory investigation. Five normal human donor eyes (mean age 69.8 years) were perfusion-labeled with endothelial antibodies and the capillary networks of the perifovea were visualized using confocal scanning laser microscopy. Regions of the capillary-free zone along the retinal artery were imaged using OCTA in 16 normal subjects (age range 24-51 years). Then, 3 × 3-mm scans were acquired using the RTVue XR Avanti (ver. 2016.1.0.26; Optovue, Inc, Fremont, California, USA), PLEX Elite 9000 (ver. 1.5.0.15909; Zeiss Meditec, Inc, Dublin, California, USA), Heidelberg Spectralis OCT2 (Family acquisition module 6.7.21.0; Heidelberg Engineering, Heidelberg, Germany), and DRI-OCT Triton (Ver. 1.1.1; Topcon Corp, Tokyo, Japan). Images of the superficial plexus, deep vascular plexus, and a slab containing all vascular plexuses were generated using manufacturer-recommended default settings. Comparisons between histology and OCTA were performed. Histologic analysis revealed that the capillary-free zone along the retinal artery was confined to the plane of the superficial capillary plexus and did not include the intermediate and deep capillary plexuses. Images derived from OCTA instruments demonstrated a prominent capillary-free zone along the retinal artery in slabs of the superficial plexus, deep plexus, and all capillary plexuses. The number of deep retinal capillaries seen in the capillary-free zone was significantly greater on histology than on OCTA (P < .001). Using the capillary-free zone as an anatomic paradigm, we show that the deep vascular beds of the retina are not completely visualized using OCTA. This may be a limitation of current OCTA techniques. Copyright © 2018 Elsevier Inc. All rights reserved.
Du, Haiqin; Zhang, Chong; Mao, Ke; Wang, Yanmei
2017-08-01
In this work, an antifouling capillary modified with star-shaped poly(2-methyl-2-oxazoline)-based copolymer was used to study the interaction between acetaminophen (APAP) and bovine serum albumin (BSA) by frontal analysis capillary electrophoresis (FACE). The star-shaped copolymer, poly(ethylene imine)-graft-poly(2-methyl-2-oxazoline) (PEI-g-PMOXA), was immobilized onto the fused-silica capillary inner wall via dopamine-assisted co-deposition strategy, yielding a PEI-g-PMOXA/polydopamine (PDA)-coated antifouling capillary, i.e., an antifouling capillary coated with the PEI-g-PMOXA/PDA co-deposited film. Electroosmotic flow (EOF) mobility of the PEI-g-PMOXA/PDA-coated capillary was almost zero in a wide pH range (3.0-10.0), while the EOF mobility of bare capillary was much larger and increased significantly with pH increasing. When the PEI-g-PMOXA/PDA-coated capillary was exploited to separate a protein mixture including cytochrome c, lysozyme, ribonuclease A and α-chymotrypsinogen A, the theoretical plate numbers were of five orders of magnitude which were about ten-fold higher over those obtained with bare capillary; in addition, the RSD values of migration time were mostly less than 0.7% (30 consecutive runs) which were much smaller than those of bare capillary (c.a. 5.7%). The protein-resistant PEI-g-PMOXA/PDA-coated capillary was then used to investigate the interaction between APAP and BSA by FACE, the binding constant and number of binding sites at 25°C and pH 7.4 (Tris/HCl buffer of 25mM) were 1.39×10 4 M -1 and 1.08, respectively, which were comparable to the results determined by fluorescence spectroscopic measurement (3.18×10 4 M -1 and 1.19, respectively). Copyright © 2017 Elsevier B.V. All rights reserved.
Capillary electrophoresis for drug analysis
NASA Astrophysics Data System (ADS)
Lurie, Ira S.
1999-02-01
Capillary electrophoresis (CE) is a high resolution separation technique which is amenable to a wide variety of solutes, including compounds which are thermally degradable, non-volatile and highly polar, and is therefore well suited for drug analysis. Techniques which have been used in our laboratory include electrokinetic chromatography (ECC), free zone electrophoresis (CZE) and capillary electrochromatography (CEC). ECC, which uses a charged run buffer additive which migrates counter to osmotic flow, is excellent for many applications, including, drug screening and analyses of heroin, cocaine and methamphetamine samples. ECC approaches include the use of micelles and charged cyclodextrins, which allow for the separation of complex mixtures. Simultaneous separation of acidic, neutral and basic solutes and the resolution of optical isomers and positional isomers are possible. CZE has been used for the analysis of small ions (cations and anions) in heroin exhibits. For the ECC and CZE experiments performed in our laboratory, uncoated capillaries were used. In contrast, CEC uses capillaries packed with high performance liquid chromatography stationary phases, and offers both high peak capacities and unique selectivities. Applications include the analysis of cannabinoids and drug screening. Although CE suffers from limited concentration sensitivity, it is still applicable to trace analysis of drug samples, especially when using injection techniques such as stacking, or detection schemes such as laser induced fluorescence and extended pathlength UV.
GC/FT-IR ANALYSIS OF THE THERMALLY LABILE COMPOUND TRIS (2,3-DIBROMOPROPYL) PHOSPHATE
A fast and convenient GC method has been developed for a compound [tris(2,3-dibromopropyl)phosphate] that poses a difficult analytical problem for both GC (thermal instability/low volatility) and LC (not amenable to commonly available, sensitive detectors) analysis. his method em...
ANALYSIS OF ANIONIC METALLIZED AZO AND FORMAZAN DYES BY CAPILLARY ELECTROPHORESIS/MASS SPECTROMETRY
Capillary electrophoresis-mass spectrometry was applied to the separation of several anionic dyes containing copper(II), chromium(III), or cobalt(III) as part of the dye molecule. The dyes were separated using a 110 cmX50 mu m uncoated fused-silica capillary and a 5 mM ammonium a...
Effect of hypothermic pulmonary artery flushing on capillary filtration coefficient.
Andrade, R S; Wangensteen, O D; Jo, J K; Tsai, M Y; Bolman, R M
2000-07-27
We previously demonstrated that surfactant dilution and inhibition occur immediately after pulmonary artery flushing with hypothermic modified Euro-Collins solution. Consequently, we speculated that increased capillary permeability contributed to these surfactant changes. To test this hypothesis, we evaluated the effects of hypothermic pulmonary artery flushing on the pulmonary capillary filtration coefficient (Kfc), and additionally performed a biochemical analysis of surfactant. We used a murine isolated, perfused lung model to measure the pulmonary capillary filtration coefficient and hemodynamic parameters, to determine the wet to dry weight ratio, and to evaluate surfactant by biochemical analysis of lung lavage fluid. We defined three study groups. In group I (controls), we harvested lungs without hypothermic pulmonary artery flushing, and measured Kfc immediately. In group II (in situ flush), we harvested lungs after hypothermic pulmonary artery flushing with modified Euro-Collins solution, and then measured Kfc. Experiments in groups I and II were designed to evaluate persistent changes in Kfc after pulmonary artery flushing. In group III (ex vivo flush), we flushed lungs ex vivo to evaluate transient changes in Kfc during hypothermic pulmonary artery flushing. Groups I and II did not differ significantly in capillary filtration coefficient and hemodynamics. Group II showed significant alterations on biochemical surfactant analysis and a significant increase in wet-to-dry weight ratio, when compared with group I. In group III, we observed a significant transient increase in capillary filtration coefficient during pulmonary artery flushing. Hypothermic pulmonary artery flushing transiently increases the capillary filtration coefficient, leads to an increase in the wet to dry weight ratio, and induces biochemical surfactant changes. These findings could be explained by the effects of hypothermic modified Euro-Collins solution on pulmonary capillary permeability.
On-line DNA analysis system with rapid thermal cycling
Swerdlow, Harold P.; Wittwer, Carl T.
1999-01-01
An apparatus particularly suited for subjecting biological samples to any necessary sample preparation tasks, subjecting the sample to rapid thermal cycling, and then subjecting the sample to subsequent on-line analysis using one or more of a number of analytical techniques. The apparatus includes a chromatography device including an injection means, a chromatography pump, and a chromatography column. In addition, the apparatus also contains a capillary electrophoresis device consisting of a capillary electrophoresis column with an inlet and outlet end, a means of injection, and means of applying a high voltage to cause the differential migration of species of interest through the capillary column. Effluent from the liquid chromatography column passes over the inlet end of the capillary electrophoresis column through a tee structure and when the loading of the capillary electrophoresis column is desired, a voltage supply is activated at a precise voltage and polarity over a specific duration to cause sample species to be diverted from the flowing stream to the capillary electrophoresis column. A laser induced fluorescence detector preferably is used to analyze the products separated while in the electrophoresis column.
On-line DNA analysis system with rapid thermal cycling
Swerdlow, H.P.; Wittwer, C.T.
1999-08-10
This application describes an apparatus particularly suited for subjecting biological samples to any necessary sample preparation tasks, subjecting the sample to rapid thermal cycling, and then subjecting the sample to subsequent on-line analysis using one or more of a number of analytical techniques. The apparatus includes a chromatography device including an injection means, a chromatography pump, and a chromatography column. In addition, the apparatus also contains a capillary electrophoresis device consisting of a capillary electrophoresis column with an inlet and outlet end, a means of injection, and means of applying a high voltage to cause the differential migration of species of interest through the capillary column. Effluent from the liquid chromatography column passes over the inlet end of the capillary electrophoresis column through a tee structure and when the loading of the capillary electrophoresis column is desired, a voltage supply is activated at a precise voltage and polarity over a specific duration to cause sample species to be diverted from the flowing stream to the capillary electrophoresis column. A laser induced fluorescence detector preferably is used to analyze the products separated while in the electrophoresis column. 6 figs.
Schober, Yvonne; Wahl, Hans Günther; Renz, Harald; Nockher, Wolfgang Andreas
2017-01-01
Cellular fatty acid (FA) profiles have been acknowledged as biomarkers in various human diseases. Nevertheless, common FA analysis by gas chromatography mass spectrometry (GC-MS) requires long analysis time. Hence, there is a need for feasible methods for high throughput analysis in clinical studies. FA was extracted from red blood cells (RBC) and derivatized to fatty acid methyl esters (FAME). A method using gas chromatography tandem mass spectrometry (GC-MS/MS) with ammonia-induced chemical ionization (CI) was developed for the analysis of FA profiles in human RBC. We compared this method with classical single GC-MS using electron impact ionization (EI). The FA profiles of 703 RBC samples were determined by GC-MS/MS. In contrast to EI ammonia-induced CI resulted in adequate amounts of molecular ions for further fragmentation of FAME. Specific fragments for confident quantification and fragmentation were determined for 45 FA. The GC-MS/MS method has a total run time of 9min compared to typical analysis times of up to 60min in conventional GC-MS. Intra and inter assay variations were <10% for all FA analyzed. Analysis of RBC FA composition revealed an age-dependent increase of the omega-3 eicosapentaenoic and docosahexaenoic acid, and a decline of the omega-6 linoleic acid with a corresponding rise of the omega-3 index. The combination of ammonia-induced CI and tandem mass spectrometry after GC separation allows for high-throughput, robust and confident analysis of FA profiles in the clinical laboratory. Copyright © 2016. Published by Elsevier B.V.
Wang, Y H; Wong, P K
2005-05-01
A simple and rapid headspace method for gas chromatographic determination of dichloroacetic acid (DCAA) and trichloroacetic acid (TCAA) in drinking water was developed. Acidic methanol esterification followed by a headspace technique using a capillary column gas chromatograph (GC) equipped with an electron capture detector (ECD) was applied to determine the levels of DCAA and TCAA in drinking water. The major advantages of this method are the use of acidic methanol as the derivatization agent instead of the hazardous diazomethane, and esterification is carried out in water instead of organic solvent. DCAA and TCAA methyl esters produced in the reaction were determined directly by a headspace GC/ECD method. The linear correlation coefficients at concentrations ranging from 0 to 60 microg/L were 0.992 and 0.996 for DCAA and TCAA, respectively. The relative standard deviations (RSD, %) for the determination of DCAA and TCAA in drinking water were 15 and 21.3%, respectively (n=3). The detection limits of this method were 3 and 0.5 microg/L for DCAA and TCAA, respectively, and the recovery was 68-103.2% for DCAA and TCAA.
Shibamoto, Shigeaki; Gooley, Andrew; Yamamoto, Kouhei
2015-01-01
Using a strongly polar cyanopropyl capillary column we have investigated the gas chromatography (GC) separation behaviors of 24 octadecadienoic acid methyl ester (18:2ME) isomers compared against saturated methyl stearate (18:0ME) and arachidic acid methyl ester (20:0ME), and the dependency on the GC column temperature. The 24 isomers were obtained by performing cis-to trans-isomerization of six regioisomers: five of the 18:2ME isomers were prepared by the partial reduction of methyl α-linolenate and methyl γ-linolenate C18 trienoic acids with different double bond positions, whereas the sixth isomer, 18:2ME (c5, c9), was obtained from a raw constituent fatty acid methyl ester (FAME) sample extracted from Japanese yew seeds. There are no reference standards commercially available for 18:2ME isomers, and in elucidating the elution order of these isomers this study should help the future identification of cis- and trans-type of 18:2ME. We also report the identification method of cis- and trans-type of FAME using equivalent chain lengths and attempt the identification of cis- and trans-type of 18:2ME isomers from partially hydrogenated canola oil.
Pello-Palma, Jairo; González-Álvarez, Jaime; Gutiérrez-Álvarez, María Dolores; Dapena de la Fuente, Enrique; Mangas-Alonso, Juan José; Méndez-Sánchez, Daniel; Gotor-Fernández, Vicente; Arias-Abrodo, Pilar
2017-04-01
A chromatographic method for the separation of volatile compounds in Asturian cider apple juices has been developed. For this separation purpose, a monocationic imidazolium-based ionic liquid bearing a reactive terminal iodine atom was synthesized by a quaternization-anion exchange chemical sequence. Next, the gas chromatography (GC) stationary phase was prepared by covalently linking the imidazolium monolith to the reactive silanol groups of the inner capillary wall at 70 °C. This coated GC column exhibited good thermal stability (290 °C), as well as good efficiency (2000 plates/m) in the separation of volatile compounds from Asturian apple cider juices, and was characterized using the Abraham solvation parameter model. The intra-day and inter-day precision of the chromatographic method was evaluated, obtaining relative standard deviations from 3.7 to 12.9% and from 7.4 to 18.0%, respectively. Furthermore, recoveries from 82.5 to 122% were achieved. Graphical Abstract Covalent bonding of an ionic liquid to inner column wall led to a great improvement of the separation efficiencies of stationary phases in gas chromatography.
Walia, Mayanka; Mann, Tavleen S.; Kumar, Dharmesh; Agnihotri, Vijai K.; Singh, Bikram
2012-01-01
Light pale-colored volatile oil was obtained from fresh leaves of Malus domestica tree, growing in Dhauladhar range of Himalaya (Himachal Pradesh, India), with characteristic eucalyptol dominant fragrance. The oil was found to be a complex mixture of mono-, sesqui-, di-terpenes, phenolics, and aliphatic hydrocarbons. Seventeen compounds accounting for nearly 95.3% of the oil were characterized with the help of capillary GC, GC-MS, and NMR. Major compounds of the oil were characterized as eucalyptol (43.7%), phytol (11.5%), α-farnesene (9.6%), and pentacosane (7.6%). Cytotoxicity of essential oil of leaves of M. domestica was evaluated by sulforhodamine B (SRB) assays. The essential oil of leaves of M. domestica, tested against three cancer cell lines, namely, C-6 (glioma cells), A549 (human lung carcinoma), CHOK1 (Chinese hamster ovary cells), and THP-1 (human acute monocytic leukemia cell). The highest activity showed by essential oil on C-6 cell lines (98.2%) at concentration of 2000 μg/ml compared to control. It is the first paper in literature to exploit the chemical composition and cytotoxic activity of leaves essential oil of M. domestica. PMID:22619691
The formation of quasi-alicyclic rings in alkyl-aromatic compounds
NASA Astrophysics Data System (ADS)
Straka, Pavel; Buryan, Petr; Bičáková, Olga
2018-02-01
The alkyl side chains of n-alkyl phenols, n-alkyl benzenes and n-alkyl naphthalenes are cyclised, as demonstrated by GC measurements, FTIR spectroscopy and molecular mechanics calculations. Cyclisation occurs due to the intramolecular interaction between an aromatic ring (-δ) and a hydrogen of the terminal methyl group (+δ) of an alkyl chain. In fact, conventional molecules are not aliphatic-aromatic, but quasi-alicyclic-aromatic. With the aromatic molecules formed with a quasi-alicyclic ring, the effect of van der Waals attractive forces increases not only intramolecularly but also intermolecularly. This effect is strong in molecules with propyl and higher alkyl substituents. The increase of intermolecular van der Waals attractive forces results in bi-linearity in the GC retention time of the compounds in question, observed in the dependence of the logarithm of the relative retention time on the number of carbons in a molecule in both polar and nonpolar stationary phases with both capillary and packed columns. The role of van der Waals forces has been demonstrated using the potential energies of covalent and noncovalent interactions for 2-n-alkyl phenols, n-alkyl benzenes and 1-n-alkyl- and 2-n-alkyl naphthalenes.
Axial thermal gradients in microchip gas chromatography.
Wang, Anzi; Hynynen, Sampo; Hawkins, Aaron R; Tolley, Samuel E; Tolley, H Dennis; Lee, Milton L
2014-12-29
Fabrication technologies for microelectromechanical systems (MEMS) allow miniaturization of conventional benchtop gas chromatography (GC) to portable, palm-sized microfabricated GC (μGC) devices, which are suitable for on-site chemical analysis and remote sensing. The separation performance of μGC systems, however, has not been on par with conventional GC. Column efficiency, peak symmetry and resolution are often compromised by column defects and non-ideal injections. The relatively low performance of μGC devices has impeded their further commercialization and broader application. In this work, the separation performance of μGC columns was improved by incorporating thermal gradient gas chromatography (TGGC). The analysis time was ∼20% shorter for TGGC separations compared to conventional temperature-programmed GC (TPGC) when a wide sample band was introduced into the column. Up to 50% reduction in peak tailing was observed for polar analytes, which improved their resolution. The signal-to-noise ratios (S/N) of late-eluting peaks were increased by 3-4 fold. The unique focusing effect of TGGC overcomes many of the previous shortcomings inherent in μGC analyses. Copyright © 2014 Elsevier B.V. All rights reserved.
Metabolomic and elemental analysis of camel and bovine urine by GC-MS and ICP-MS.
Ahamad, Syed Rizwan; Alhaider, Abdul Qader; Raish, Mohammad; Shakeel, Faiyaz
2017-01-01
Recent studies from the author's laboratory indicated that camel urine possesses antiplatelet activity and anti-cancer activity which is not present in bovine urine. The objective of this study is to compare the volatile and elemental components of bovine and camel urine using GC-MS and ICP-MS analysis. We are interested to know the component that performs these biological activities. The freeze dried urine was dissolved in dichloromethane and then derivatization process followed by using BSTFA for GC-MS analysis. Thirty different compounds were analyzed by the derivatization process in full scan mode. For ICP-MS analysis twenty eight important elements were analyzed in both bovine and camel urine. The results of GC-MS and ICP-MS analysis showed marked difference in the urinary metabolites. GC-MS evaluation of camel urine finds a lot of products of metabolism like benzene propanoic acid derivatives, fatty acid derivatives, amino acid derivatives, sugars, prostaglandins and canavanine. Several research reports reveal the metabolomics studies on camel urine but none of them completely reported the pharmacology related metabolomics. The present data of GC-MS suggest and support the previous studies and activities related to camel urine.
Fong, Sim S.; Rearden, Preshious; Kanchagar, Chitra; Sassetti, Christopher; Trevejo, Jose; Brereton, Richard G.
2013-01-01
A gas chromatography–differential mobility spectrometer (GC-DMS) involves a portable and selective mass analyzer that may be applied to chemical detection in the field. Existing approaches examine whole profiles and do not attempt to resolve peaks. A new approach for peak detection in the 2D GC-DMS chromatograms is reported. This method is demonstrated on three case studies: a simulated case study; a case study of headspace gas analysis of Mycobacterium tuberculosis (MTb) cultures consisting of three matching GC-DMS and GC-MS chromatograms; a case study consisting of 41 GC-DMS chromatograms of headspace gas analysis of MTb culture and media. PMID:21204557
Quality Assurance Guidelines for Organic Analysis
1989-12-01
Captan GC 509A a, p 7 Carbaryl TLC a, p 94; c, p S60 Carbophenothion GC b, p 30; c, p S73 Chlordane GC 608 509A D3086 a, p 7 GC/MS 625 Chloroprophan...c, p S64 Propoxur TLC a, p 94; c, p S60 Secbumeton TLC a, p 83; c, p S68 Siduron TLC a, p 104; c, p S64 Simazine GC a, p 83; c, p S68 Strobane GC
Emiralioğlu, Nagehan; Özçelik, Uğur; Yalçın, Ebru; Doğru, Deniz; Kiper, Nural
2016-01-01
Sweat test with Gibson Cooke (GC) method is the diagnostic gold standard for cystic fibrosis (CF). Recently, alternative methods have been introduced to simplify both the collection and analysis of sweat samples. Our aim was to compare sweat chloride values obtained by GC method with other sweat test methods in patients diagnosed with CF and whose CF diagnosis had been ruled out. We wanted to determine if the other sweat test methods could reliably identify patients with CF and differentiate them from healthy subjects. Chloride concentration was measured with GC method, chloride meter and sweat test analysis system; also conductivity was determined with sweat test analysis system. Forty eight patients with CF and 82 patients without CF underwent the sweat test, showing median sweat chloride values 98.9 mEq/L with GC method, 101 mmol/L with chloride meter, 87.8 mmol/L with sweat test analysis system. In non-CF group, median sweat chloride values were 16.8 mEq/L with GC method, 10.5 mmol/L with chloride meter, and 15.6 mmol/L with sweat test analysis system. Median conductivity value was 107.3 mmol/L in CF group and 32.1 mmol/L in non CF group. There was a strong positive correlation between GC method and the other sweat test methods with a statistical significance (r=0.85) in all subjects. Sweat chloride concentration and conductivity by other sweat test methods highly correlate with the GC method. We think that the other sweat test equipments can be used as reliably as the classic GC method to diagnose or exclude CF.
Váradi, Csaba; Mittermayr, Stefan; Millán-Martín, Silvia; Bones, Jonathan
2016-12-01
Capillary electrophoresis (CE) offers excellent efficiency and orthogonality to liquid chromatographic (LC) separations for oligosaccharide structural analysis. Combination of CE with high resolution mass spectrometry (MS) for glycan analysis remains a challenging task due to the MS incompatibility of background electrolyte buffers and additives commonly used in offline CE separations. Here, a novel method is presented for the analysis of 2-aminobenzoic acid (2-AA) labelled glycans by capillary electrophoresis coupled to mass spectrometry (CE-MS). To ensure maximum resolution and excellent precision without the requirement for excessive analysis times, CE separation conditions including the concentration and pH of the background electrolyte, the effect of applied pressure on the capillary inlet and the capillary length were evaluated. Using readily available 12/13 C 6 stable isotopologues of 2-AA, the developed method can be applied for quantitative glycan profiling in a twoplex manner based on the generation of extracted ion electropherograms (EIE) for 12 C 6 'light' and 13 C 6 'heavy' 2-AA labelled glycan isotope clusters. The twoplex quantitative CE-MS glycan analysis platform is ideally suited for comparability assessment of biopharmaceuticals, such as monoclonal antibodies, for differential glycomic analysis of clinical material for potential biomarker discovery or for quantitative microheterogeneity analysis of different glycosylation sites within a glycoprotein. Additionally, due to the low injection volume requirements of CE, subsequent LC-MS analysis of the same sample can be performed facilitating the use of orthogonal separation techniques for structural elucidation or verification of quantitative performance.
Bagdasarov, G. A.; Bobrova, N. A.; Boldarev, A. S.; ...
2017-12-27
A method for the asymmetric focusing of electron bunches, based on the active plasma lensing technique is proposed. Our method takes advantage of the strong inhomogeneous magnetic field generated inside the capillary discharge plasma to focus the ultrarelativistic electrons. The plasma and magnetic field parameters inside the capillary discharge are described theoretically and modeled with dissipative magnetohydrodynamic computer simulations enabling analysis of the capillaries of rectangle cross-sections. We could use large aspect ratio rectangular capillaries to transport electron beams with high emittance asymmetries, as well as assist in forming spatially flat electron bunches for final focusing before the interaction point.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bagdasarov, G. A.; Bobrova, N. A.; Boldarev, A. S.
A method for the asymmetric focusing of electron bunches, based on the active plasma lensing technique is proposed. Our method takes advantage of the strong inhomogeneous magnetic field generated inside the capillary discharge plasma to focus the ultrarelativistic electrons. The plasma and magnetic field parameters inside the capillary discharge are described theoretically and modeled with dissipative magnetohydrodynamic computer simulations enabling analysis of the capillaries of rectangle cross-sections. We could use large aspect ratio rectangular capillaries to transport electron beams with high emittance asymmetries, as well as assist in forming spatially flat electron bunches for final focusing before the interaction point.
NASA Astrophysics Data System (ADS)
Bagdasarov, G. A.; Bobrova, N. A.; Boldarev, A. S.; Olkhovskaya, O. G.; Sasorov, P. V.; Gasilov, V. A.; Barber, S. K.; Bulanov, S. S.; Gonsalves, A. J.; Schroeder, C. B.; van Tilborg, J.; Esarey, E.; Leemans, W. P.; Levato, T.; Margarone, D.; Korn, G.; Kando, M.; Bulanov, S. V.
2017-12-01
A method for the asymmetric focusing of electron bunches, based on the active plasma lensing technique, is proposed. This method takes advantage of the strong inhomogeneous magnetic field generated inside the capillary discharge plasma to focus on the ultrarelativistic electrons. The plasma and magnetic field parameters inside the capillary discharge are described theoretically and modeled with dissipative magnetohydrodynamic computer simulations enabling analysis of the capillaries of rectangle cross-sections. Large aspect ratio rectangular capillaries might be used to transport electron beams with high emittance asymmetries, as well as assist in forming spatially flat electron bunches for final focusing before the interaction point.
Molecular dysexpression in gastric cancer revealed by integrated analysis of transcriptome data.
Li, Xiaomei; Dong, Weiwei; Qu, Xueling; Zhao, Huixia; Wang, Shuo; Hao, Yixin; Li, Qiuwen; Zhu, Jianhua; Ye, Min; Xiao, Wenhua
2017-05-01
Gastric cancer (GC) is often diagnosed in the advanced stages and is associated with a poor prognosis. Obtaining an in depth understanding of the molecular mechanisms of GC has lagged behind compared with other cancers. This study aimed to identify candidate biomarkers for GC. An integrated analysis of microarray datasets was performed to identify differentially expressed genes (DEGs) between GC and normal tissues. Gene ontology and Kyoto Encyclopedia of Genes and Genomes (KEGG) enrichment analyses were then performed to identify the functions of the DEGs. Furthermore, a protein-protein interaction (PPI) network of the DEGs was constructed. The expression levels of the DEGs were validated in human GC tissues using reverse transcription-quantitative polymerase chain reaction (RT-qPCR). A set of 689 DEGs were identified in GC tissues, as compared with normal tissues, including 202 upregulated DEGs and 487 downregulated DEGs. The KEGG pathway analysis suggested that various pathways may play important roles in the pathology of GC, including pathways related to protein digestion and absorption, extracellular matrix-receptor interaction, and the metabolism of xenobiotics by cytochrome P450. The PPI network analysis indicated that the significant hub proteins consisted of SPP1, TOP2A and ARPC1B. RT-qPCR validation indicated that the expression levels of the top 10 most significantly dysexpressed genes were consistent with the illustration of the integrated analysis. The present study yielded a reference list of reliable DEGs, which represents a robust pool of candidates for further evaluation of GC pathogenesis and treatment.
Zhou, Fei; Zhao, Yajing; Peng, Jiyu; Jiang, Yirong; Li, Maiquan; Jiang, Yuan; Lu, Baiyi
2017-07-01
Osmanthus fragrans flowers are used as folk medicine and additives for teas, beverages and foods. The metabolites of O. fragrans flowers from different geographical origins were inconsistent in some extent. Chromatography and mass spectrometry combined with multivariable analysis methods provides an approach for discriminating the origin of O. fragrans flowers. To discriminate the Osmanthus fragrans var. thunbergii flowers from different origins with the identified metabolites. GC-MS and UPLC-PDA were conducted to analyse the metabolites in O. fragrans var. thunbergii flowers (in total 150 samples). Principal component analysis (PCA), soft independent modelling of class analogy analysis (SIMCA) and random forest (RF) analysis were applied to group the GC-MS and UPLC-PDA data. GC-MS identified 32 compounds common to all samples while UPLC-PDA/QTOF-MS identified 16 common compounds. PCA of the UPLC-PDA data generated a better clustering than PCA of the GC-MS data. Ten metabolites (six from GC-MS and four from UPLC-PDA) were selected as effective compounds for discrimination by PCA loadings. SIMCA and RF analysis were used to build classification models, and the RF model, based on the four effective compounds (caffeic acid derivative, acteoside, ligustroside and compound 15), yielded better results with the classification rate of 100% in the calibration set and 97.8% in the prediction set. GC-MS and UPLC-PDA combined with multivariable analysis methods can discriminate the origin of Osmanthus fragrans var. thunbergii flowers. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Identification and differentiation of methcathinone analogs by gas chromatography-mass spectrometry.
Tsujikawa, Kenji; Mikuma, Toshiyasu; Kuwayama, Kenji; Miyaguchi, Hajime; Kanamori, Tatsuyuki; Iwata, Yuko T; Inoue, Hiroyuki
2013-08-01
To overcome a number of challenges involved in analyzing methcathinone (MC) analogues, we performed gas chromatography-mass spectrometry (GC-MS) analysis, including sample preparation, of nine MC analogues - 4-methylmethcathinone, three positional isomers of fluoromethcathinones, 4-methoxymethcathinone, N-ethylcathinone, N,N-dimethylcathinone, buphedrone, and pentedrone. The MC analogues underwent dehydrogenation when the free bases were analyzed using splitless injection. Most of this thermal degradation was prevented using split injection. This indicated that a shorter residence time in the hot injector prevented decomposition. Uniquely, 2-fluoromethcathinone degraded to another product in a process that could not be prevented by the split injection. Replacing the liner with a new, clean one was also effective in preventing thermal degradation. Most of the analytes showed a substantial loss (>30%) when the free base solution in ethyl acetate was evaporated under a nitrogen stream. Adding a small amount of dimethylformamide as a solvent keeper had a noticeable effect, but it did not completely prevent the loss. Three positional isomers of fluoromethcathinones were separated with baseline resolution by heptafluorobutyrylation with a slow column heating rate (8 °C/min) using a non-polar DB-5 ms capillary column. These results will be useful for the forensic analysis of MC analogues in confiscated materials. Copyright © 2012 John Wiley & Sons, Ltd.
ERIC Educational Resources Information Center
Albright, Jessica C.; Beussman, Douglas J.
2017-01-01
Capillary electrophoresis is an important analytical separation method used to study a wide variety of samples, including those of biological origin. Capillary electrophoresis may be covered in the classroom, especially in advanced analytical courses, and while many students are exposed to gel electrophoresis in biology or biochemistry…
Focused analyte spray emission apparatus and process for mass spectrometric analysis
Roach, Patrick J [Kennewick, WA; Laskin, Julia [Richland, WA; Laskin, Alexander [Richland, WA
2012-01-17
An apparatus and process are disclosed that deliver an analyte deposited on a substrate to a mass spectrometer that provides for trace analysis of complex organic analytes. Analytes are probed using a small droplet of solvent that is formed at the junction between two capillaries. A supply capillary maintains the droplet of solvent on the substrate; a collection capillary collects analyte desorbed from the surface and emits analyte ions as a focused spray to the inlet of a mass spectrometer for analysis. The invention enables efficient separation of desorption and ionization events, providing enhanced control over transport and ionization of the analyte.
ERIC Educational Resources Information Center
Pacot, Giselle Mae M.; Lee, Lyn May; Chin, Sung-Tong; Marriott, Philip J.
2016-01-01
Gas chromatography-mass spectrometry (GC-MS) and GC-tandem MS (GC-MS/MS) are useful in many separation and characterization procedures. GC-MS is now a common tool in industry and research, and increasingly, GC-MS/MS is applied to the measurement of trace components in complex mixtures. This report describes an upper-level undergraduate experiment…
NASA Astrophysics Data System (ADS)
Mossoba, Magdi M.; McDonald, Richard E.; Chen, Jo-Yun T.; Page, Samuel W.
1989-12-01
Geometric and positional isomers of fatty acid methyl esters (FAME) derived from hydrogenated soybean oil and margarines were separated by silver nitrate-thin layer chromatography (AgNO3-TLC) followed by capillary gas chromatography (GC) and identified by matrix isolation / Fourier transform infrared (MI/FTIR) spectroscopyi,2. Because of the high specificity of the MI technique, it was possible to distinguish between different 18-carbon aliphatic chains of FAME positional isomers with cis or trans configuration, and to determine their degree of unsaturation. For the first time mid-IR spectra were observed for methylene-interrupted or isolated trans, trans or cis/ trans C18 FAME positional isomers. These spectra could be readily differentiated based on unique MI/FTIR spectral characteristics.
Leiker, T.J.; Rostad, C.E.; Barnes, C.R.; Pereira, W.E.
1991-01-01
Blue catfish, (Ictarurus furcatus), black bullhead catfish, (Ictalurus melas), channel catfish (Ictalurus punctatus), and flathead catfish (Pylodictus olivaris), were collected along a 1200 mile river reach of the Mississippi River and its major tributaries. Tissue samples were extracted and analyzed by fused silica capillary gas chromatography/mass spectrometry (GC/MS) to determine the concentrations of hydrophobic organic halogenated contaminants that have bioconcentrated within the tissues. The compounds identified in the tissue include chlordane, polychlorinated biphenyls (PCBs), DDT and its metabolites along with several other chlorinated pesticides. The data indicates that the southern reach of the river system appears to be more contaminated than the middle and upper reaches of the study area.
Xie, Sheng-Ming; Zhang, Mei; Fei, Zhi-Xin; Yuan, Li-Ming
2014-10-10
Chiral metal-organic frameworks (MOFs) are a new class of multifunctional material, which possess diverse structures and unusual properties such as high surface area, uniform and permanent cavities, as well as good chemical and thermal stability. Their chiral functionality makes them attractive as novel enantioselective adsorbents and stationary phases in separation science. In this paper, the experimental comparison of a chiral MOF [In₃O(obb)₃(HCO₂)(H₂O)] solvent used as a stationary phase was investigated in gas chromatography (GC), high-performance liquid chromatography (HPLC) and capillary electrochromatography (CEC). The potential relationship between the structure and components of chiral MOFs with their chiral recognition ability and selectivity are presented. Copyright © 2014 Elsevier B.V. All rights reserved.
Determination of Acylglycerols in Diesel Oils by GC
Wawrzyniak, Rafał; Wasiak, Wiesław
2008-01-01
In many EU countries and outside the EU, besides the addition of pure methyl ester B-100 to diesel oil, mixtures of methyl esters are also added to fuel. To be used as fuel, methyl esters must meet certain requirements, one of which is a certain level of acylglycerols. The paper presents results of determination of acylglycerols in diesel oil dotted with fatty acid methyl esters. The compounds were determined by gas chromatography using a high-temperature capillary column DB-5HT, made by J&W, and 1,2,3-tricaproylglycerol as internal standard. The analytical method proposed permits not only determination of acylglycerols, but also differentiation if the FAME added originated from pure vegetation oil or used cooking oil. PMID:19696907
NASA Astrophysics Data System (ADS)
Nik Him, N. R.; Huda, T.
2018-05-01
Study on the production of bioethanol using palm oil empty fruit bunch (EFB) has been performed using actinomycete Streptosporangium roseum. Positive result of bioethanol production was recorded using Iodoform test followed by confirmation with GC-FID using a polar capillary column (PEG-type, 10m x 0.53, with autosampler) and n-propanol as internal standard. The first and second round distillation has produced azeotrope (85-15% ethanol-water) and the third round has concentrated the ethanol to 96.1%. Therefore, the process was accomplished by using molecular sieves that selectively absorbed the final excess water. Direct fermentation using Streptosporangium roseum has shown to be a very potential way to catalyst for the synthesis of bioethanol from EFB.
Horká, Marie; Karásek, Pavel; Salplachta, Jiří; Růžička, Filip; Vykydalová, Marie; Kubesová, Anna; Dráb, Vladimír; Roth, Michal; Slais, Karel
2013-07-25
In this study, combination of capillary isoelectric focusing (CIEF) in tapered fused silica (FS) capillary with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is presented as an efficient approach for unambiguous identification of probiotic bacteria in real sample. For this purpose, bacteria within genus Lactobacillus were selected as model bioanalytes and cow's milk was selected as a biological sample. CIEF analysis of both the cultivated bacteria and the bacteria in the milk was optimized and isoelectric points characterizing the examined bacteria were subsequently determined independently of the bacterial sample origin. The use of tapered FS capillary significantly enhanced the separation capacity and efficiency of the CIEF analyses performed. In addition, the cell number injected into the tapered FS capillary was quantified and an excellent linearity of the calibration curves was achieved which enabled quantitative analysis of the bacteria by CIEF with UV detection. The minimum detectable number of bacterial cells was 2×10(6) mL(-1). Finally, cow's milk spiked with the selected bacterium was analyzed by CIEF in tapered FS capillary, the focused and detected bacterial cells were collected from the capillary, deposited onto the cultivation medium, and identified using MALDI-TOF MS afterward. Our results have revealed that the proposed procedure can be advantageously used for unambiguous identification of probiotic bacteria in a real sample. Copyright © 2013 Elsevier B.V. All rights reserved.
Li, Jing; Dong, Fengshou; Xu, Jun; Liu, Xingang; Li, Yuanbo; Shan, Weili; Zheng, Yongquan
2011-09-19
A rapid and effective method for enantioselective determination of simeconazole enantiomers in food products (cucumber, tomato, apple, pear, wheat and rice) has been developed. The enantiomers were resolved by capillary gas chromatography (GC) using a commercial chiral column (BGB-172) and a temperature program from 150°C (held for 1 min) and then raised at 10°C min(-1) to 240°C (held for 10 min). This enantioselective gas chromatographic separation was combined with a clean-up/enrichment procedure based on the modification of QuEChERS (quick, easy, cheap, effective, rugged and safe) method. Co-extractives were removed with graphitized carbon black/primary secondary amine (GCB/PSA) solid-phase extraction (SPE) cartridges using acetonitrile:toluene (3:1, v/v) as eluent. Gas chromatography/ion trap mass spectrometry (GC-ITMS) with electron ionization (EI) was then used for qualitative and quantitative determination of the simeconazole enantiomers. Two precursor-to-product ion transitions (m/z 121-101 and 195-153) with the best signal intensity were chosen to build the multiple-reaction monitoring (MRM) acquisition method. The limits of detection for each enantiomer of simeconazole in six food products ranged between 0.4 and 0.9 μg kg(-1), which were much lower than maximum residue levels (MRLs) established by Japan. The methodology was successfully applied for the enantioselective analysis of simeconazole enantiomers in real samples, indicating its efficacy in investigating the environmental stereochemistry of simeconazole in food matrix. Copyright © 2011 Elsevier B.V. All rights reserved.
Nagasawa, Hideko; Sasaki, Hideyuki; Uto, Yoshihiro; Kubo, Shinichi; Hori, Hitoshi
2004-01-01
Serum vitamin D-binding protein (Gc protein or DBP) is a highly expressed polymorphic protein, which is a precursor of the inflammation-primed macrophage activating factor, GcMAF, by a cascade of carbohydrate processing reactions. In order to elucidate the relationship between Gc polymorphism and GcMAF precursor activity, we estimated the phagocytic ability of three homotypes of Gc protein, Gc1F-1F, Gc1S-1S and Gc2-2, through processing of their carbohydrate moiety. We performed Gc typing of human serum samples by isoelectric focusing (IEF). Gc protein from human serum was purified by affinity chromatography with 25-hydroxyvitamin D3-sepharose. A phagocytosis assay of Gc proteins, modified using beta-glycosidase and sialidase, was carried out. The Gc1F-1F phenotype was revealed to possess Galbeta1-4GalNAc linkage by the analysis of GcMAF precursor activity using beta1-4 linkage-specific galactosidase from jack bean. The GcMAF precursor activity of the Gc1F-1F phenotype was highest among three Gc homotypes. The Gc polymorphism and carbohydrate diversity of Gc protein are significant for its pleiotropic effects.
Li, Yihan; Wojcik, Roza; Dovichi, Norman J.
2010-01-01
We describe a two-dimensional capillary electrophoresis system that incorporates a replaceable enzymatic microreactor for on-line protein digestion. In this system, trypsin is immobilized on magnetic beads. At the start of each experiment, old beads are flushed to waste and replaced with a fresh plug of beads, which is captured by a pair of magnets at the distal tip of the first capillary. For analysis, proteins are separated in the first capillary. A fraction is then parked in the reactor to create peptides. Digested peptides are periodically transferred to the second capillary for separation; a fresh protein fraction is simultaneously moved to the reactor for digestion. An electrospray interface is used to introduce peptides into a mass spectrometer for analysis. This procedure is repeated for several dozen fractions under computer control. The system was demonstrated by the separation and digestion of insulin chain b oxidized and β-casein as model proteins. PMID:21030030
R-134a qualification -- industry refrigerator capillary data
DOE Office of Scientific and Technical Information (OSTI.GOV)
DeVos, R.
1997-12-31
With the phaseout of R-12, the use of R-134a and polyolester (POE) oil became the preferred refrigerant/oil combination for the refrigerator appliance industry. Reliability data for this refrigerant/oil combination were minimal, and initial testing showed a propensity for the capillary tubes to clog with a variety of contaminants. A test was designed by an industry group to accelerate the process of contamination and capillary plugging. This paper presents capillary tube stress test data that were developed for this group by its member companies. This study investigated the relationship between capillary tube restriction levels and variables including compressor type, oil type,more » chlorine level, and moisture level. Analysis of the contaminants included a visual description, infrared spectroscopy, scanning electron microscope examination, and measurements of total chlorine content and noncondensable gas content of the refrigerant. Oil samples were measured for moisture level, dissolved iron, and total acid, and an infrared spectral analysis was performed.« less
Genes encoding intrinsic disorder in Eukaryota have high GC content
Peng, Zhenling; Uversky, Vladimir N.
2016-01-01
ABSTRACT We analyze a correlation between the GC content in genes of 12 eukaryotic species and the level of intrinsic disorder in their corresponding proteins. Comprehensive computational analysis has revealed that the disordered regions in eukaryotes are encoded by the GC-enriched gene regions and that this enrichment is correlated with the amount of disorder and is present across proteins and species characterized by varying amounts of disorder. The GC enrichment is a result of higher rate of amino acid coded by GC-rich codons in the disordered regions. Individual amino acids have the same GC-content profile between different species. Eukaryotic proteins with the disordered regions encoded by the GC-enriched gene segments carry out important biological functions including interactions with RNAs, DNAs, nucleotides, binding of calcium and metal ions, are involved in transcription, transport, cell division and certain signaling pathways, and are localized primarily in nucleus, cytosol and cytoplasm. We also investigate a possible relationship between GC content, intrinsic disorder and protein evolution. Analysis of a devised “age” of amino acids, their disorder-promoting capacity and the GC-enrichment of their codons suggests that the early amino acids are mostly disorder-promoting and their codons are GC-rich while most of late amino acids are mostly order-promoting. PMID:28232902
Jumhawan, Udi; Putri, Sastia Prama; Yusianto; Bamba, Takeshi; Fukusaki, Eiichiro
2015-11-01
Development of authenticity screening for Asian palm civet coffee, the world-renowned priciest coffee, was previously reported using metabolite profiling through gas chromatography/mass spectrometry (GC/MS). However, a major drawback of this approach is the high cost of the instrument and maintenance. Therefore, an alternative method is needed for quality and authenticity evaluation of civet coffee. A rapid, reliable and cost-effective analysis employing a universal detector, GC coupled with flame ionization detector (FID), and metabolite fingerprinting has been established for discrimination analysis of 37 commercial and non-commercial coffee beans extracts. gas chromatography/flame ionization detector (GC/FID) provided higher sensitivity over a similar range of detected compounds than GC/MS. In combination with multivariate analysis, GC/FID could successfully reproduce quality prediction from GC/MS for differentiation of commercial civet coffee, regular coffee and coffee blend with 50 wt % civet coffee content without prior metabolite details. Our study demonstrated that GC/FID-based metabolite fingerprinting can be effectively actualized as an alternative method for coffee authenticity screening in industries. Copyright © 2015. Published by Elsevier B.V.
Malik, Manzoor Ahmad; Shukla, Swati; Azad, Shorya Vardhan; Kaur, Jasbir
2014-01-01
Purpose Vascular endothelial growth factor polymorphism (VEGF-634G/C, rs 2010963) has been considered a risk factor for the development of retinopathy of prematurity (ROP). However, the results remain controversial. Therefore, the aim of the present meta-analysis was to determine the association between VEGF-634G/C polymorphism and ROP risk. Methods Published literature from PubMed and other databases were retrieved. All studies evaluating the association between VEGF-634G/C polymorphism and ROP risk were included. Pooled odds ratio (OR) and 95% confidence interval (CI) were calculated using random or fixed effects model. A total of six case-control studies including 355 cases and 471 controls were included. Results By pooling all the studies, we found that VEGF-634G/C polymorphism was not associated with ROP risk at co-dominant and allele levels and no association was also found in dominant and recessive models. While stratifying on ethnicity level no association was observed in Caucasian and Asian population. Discussion This meta-analysis suggests that VEGF-634G/C polymorphism may not be associated with ROP risk, the association between single VEGF-634G/C polymorphism and ROP risk awaits further investigation. PMID:25473347
Capillary Flow in Containers of Polygonal Section: Theory and Experiment
NASA Technical Reports Server (NTRS)
Weislogel, Mark M.; Rame, Enrique (Technical Monitor)
2001-01-01
An improved understanding of the large-length-scale capillary flows arising in a low-gravity environment is critical to that engineering community concerned with the design and analysis of spacecraft fluids management systems. Because a significant portion of liquid behavior in spacecraft is capillary dominated it is natural to consider designs that best exploit the spontaneous character of such flows. In the present work, a recently verified asymptotic analysis is extended to approximate spontaneous capillary flows in a large class of cylindrical containers of irregular polygonal section experiencing a step reduction in gravitational acceleration. Drop tower tests are conducted using partially-filled irregular triangular containers for comparison with the theoretical predictions. The degree to which the experimental data agree with the theory is a testament to the robustness of the basic analytical assumption of predominantly parallel flow. As a result, the closed form analytical expressions presented serve as simple, accurate tools for predicting bulk flow characteristics essential to practical low-g system design and analysis. Equations for predicting corner wetting rates, total container flow rates, and transient surfaces shapes are provided that are relevant also to terrestrial applications such as capillary flow in porous media.
ERIC Educational Resources Information Center
Hijnen, Hens
2009-01-01
A theoretical description of the influence of electroosmosis on the effective mobility of simple ions in capillary zone electrophoresis is presented. The mathematical equations derived from the space-charge model contain the pK[subscript a] value and the density of the weak acid surface groups as parameters characterizing the capillary. It is…
Analysis of HbA1c on an automated multicapillary zone electrophoresis system.
Rollborn, Niclas; Åkerfeldt, Torbjörn; Nordin, Gunnar; Xu, Xiao Yan; Mandic-Havelka, Aleksandra; Hansson, Lars-Olof; Larsson, Anders
2017-02-01
Hemoglobin A1c (HbA1c) is a frequently requested laboratory test and there is thus a need for high throughput instruments for this assay. We evaluated a new automated multicapillary zone electrophoresis instrument (Capillarys 3 Tera, Sebia, Lisses, France) for analysis of HbA1c in venous samples. Routine requested HbA1c samples were analyzed immunologically on a Roche c6000 instrument (n = 142) and then with the Capillarys 3 Tera instrument. The Capillarys 3 Tera instrument performed approximately 70 HbA1c tests/hour. There was a strong linear correlation between Capillarys 3 Tera and Roche Tina-Quant HbA1c Gen 3 assay (y = 1.003x - 0.3246 R 2 = .996). The total CV for the 12 capillaries varied between 0.8 and 2.2% and there was a good agreement between duplicate samples (R 2 = .997). In conclusion, the Capillarys 3 Tera instrument has a high assay capacity for HbA1c. It has a good precision and agreement with the Roche Tina-Quant HbA1c method and is well suited for high volume testing of HbA1c.
Miniaturized flow injection analysis system
Folta, James A.
1997-01-01
A chemical analysis technique known as flow injection analysis, wherein small quantities of chemical reagents and sample are intermixed and reacted within a capillary flow system and the reaction products are detected optically, electrochemically, or by other means. A highly miniaturized version of a flow injection analysis system has been fabricated utilizing microfabrication techniques common to the microelectronics industry. The microflow system uses flow capillaries formed by etching microchannels in a silicon or glass wafer followed by bonding to another wafer, commercially available microvalves bonded directly to the microflow channels, and an optical absorption detector cell formed near the capillary outlet, with light being both delivered and collected with fiber optics. The microflow system is designed mainly for analysis of liquids and currently measures 38.times.25.times.3 mm, but can be designed for gas analysis and be substantially smaller in construction.
Suction and cohesion demise in desaturating granular medium
NASA Astrophysics Data System (ADS)
Hueckel, T.; Mielniczuk, B.; El-Youssoufi, S. M.
2017-12-01
Continuum mechanics for unsaturated soils is based on the assumption of a one-to-one relationship betwee saturation degree and suction represented by the characteristic curve. Such curve commonly shows exceedingly high values of suction at saturation decreasing below 10%. We have performed a series of experiments on physical micro-structural models of 8-, 5, 4, 3, and 2-grain assemblies filled with water forming capillary, funicular and pendular bridges. Dynamic variables characterizing the evolution include: Laplace pressure, surface tension force, total intergralular force, contact angle and contact perimeter length. The Laplace pressure was calculated from the directly measured curvatures of interface surface for 2-grain bridges, and estimated from tomography stills for 3 grain bridges. The initial negative Laplace pressure (suction) as well as total intergranular force increase modestly at the begining of evaporation, but undergo an unstable decrease at the advanced stage, often with a jump in the force known as a Haines jumps since 1925. Laplace pressure turns into positive values prior to rupture for 2-grain bodies. For 3-grain bridges there is never an exceedingly high intergranular force of suction, reported in macro-scale experiments. For multiple-grain bodies there are two types of instabilities, depending on densitiy of the assembly and the Gaussian curvature (GC): at positive GC points it is thin-sheet instability, while at negative GC points instability is linked with air entry fingers, all associated with the split of assemblies into smaller isolated funicular, and eventually pendular bodies. The multi-grain bridges instabilities are linked to material drying cracking, the instabilities in 2 grain systems mean eventual loss of cohesion.
Water soluble dicarboxylic acids and related compounds in Antarctic aerosols
NASA Astrophysics Data System (ADS)
Kawamura, Kimitaka; SeméRé, Richard; Imai, Yoshie; Fujii, Yoshiyuki; Hayashi, Masahiko
1996-08-01
Antarctic aerosols collected at Syowa Station were studied for water soluble organic compounds by employing a water extraction and dibutyl ester derivatization and using a capillary gas chromatography (GC) and GC/mass spectrometry (GC/MS). Total carbon and nitrogen were also determined. A homologous series of α,ω-dicarboxylic acids (C2-C11), ω-oxocarboxylic acids (C2-C9), and α-dicarbonyls (C2-C3) were detected, as well as pyruvic acid and aromatic (phthalic) diacid. Succinic (C4) or oxalic (C2) acid was found to be the dominant diacid species, followed by azelaic (C9), adipic (C6), or malonic (C3) acid. Concentration range of the total diacids was 5.9-88 ng m-3, with an average of 29 ng m-3. Highest concentrations were observed in the summer sample with a predominance of succinic acid (61.5 ng m-3), which comprised approximately 70% of the total diacids and accounted for 3.5% of total aerosol carbon (1020 ng m-3). The succinic acid (C4) is likely produced by photooxidation of 4-oxocarboxylic acids, which are present in the atmosphere as intermediates of the photooxidation of unsaturated fatty acids. These results indicate that the Antarctic organic aerosols originate from marine-derived lipids and are transformed largely by photochemical oxidations. ω-Oxocarboxylic acids (C2-C9, 0.36-3.0 ng m-3) also showed the highest concentration in the summer sample, again suggesting a secondary production in the atmosphere of the Antarctic and in the Southern Ocean.
Frankel, E N; Tappel, A L
1991-06-01
An improved headspace capillary gas chromatographic (GC) method was developed to measure the oxidative susceptibility of human red blood cell (RBC) membranes. This method analyzed volatile peroxidation products of both n-6 (hexanal and pentane) and n-3 (propanal) polyunsaturated fatty acids. Oxidative susceptibility tests were standardized by incubating in a sealed 10-mL headspace bottle 0.25 or 1 mL of human RBC membrane in 40 mM phosphate buffer for 1 hr at 37 degrees C with a mixture of Fe++, ascorbic acid and H2O2. Sodium dodecyl sulfate increased significantly the amount of hexanal measured by headspace GC. By this standard headspace method, in one series of red blood cell membranes (RBCM) samples a four-fold variation in oxidative susceptibility was observed in RBCM from blood freshly drawn from six healthy subjects. In another series of RBCM samples a sixteen-fold variation in oxidative susceptibility was noted in frozen RBCM from blood freshly drawn from five healthy subjects. Correlation between hexanal formation and polyunsaturated fatty acids (PUFA) depletion provided good evidence that under these standard conditions hexanal is exclusively derived from the oxidation of arachidonic acid. Hydroperoxides of arachidonic acid are more readily formed and decomposed than those of linoleic acid in the presence of Fe++, ascorbic acid and H2O2 to produce hexanal as the main product that can be readily analyzed by headspace GC. This method may provide a useful tool to study susceptibility toward lipid peroxidative damage in human RBC membranes.
Ferslew, K E; Hagardorn, A N; McCormick, W F
1989-01-01
A case is presented of a death caused by self-injection of sufentanil and midazolam. Biological fluids and tissues were analyzed for midazolam by high performance liquid chromatography (HPLC) and gas chromatography/mass spectrometry (GC/MS) and for sufentanil by GC/MS. Midazolam was extracted from basified fluids or tissues homogenated with n-butyl chloride and analyzed by HPLC by using a phosphate buffer: acetonitrile (60:40) mobile phase on a mu-Bondapak C18 column at 240 nm. Sufentanil was extracted from basified fluids and tissue homogenates with hexane:ethanol (19:1). GC/MS methodology for both compounds consisted of chromatographic separation on a 15-m by 0.25-mm inside diameter (ID) DB-5 (1.0-micron-thick film) bonded phase fused silica capillary column with helium carrier (29 cm/s) splitless injection at 260 degrees C; column 200 degrees C (0.8 min) 10 degrees C/min to 270 degrees C; and electron ionization and multiple ion detection for midazolam (m/z 310), methaqualone (IS, m/z 235), sufentanil (m/z 289), and fentanyl (IS, m/z 245). Sufentanil concentrations were: blood 1.1 ng/mL, urine 1.3 ng/mL, vitreous humor 1.2 ng/mL, liver 1.75 ng/g, and kidney 5.5 ng/g. Midazolam concentrations were: blood 50 ng/mL, urine 300 ng/mL, liver 930 ng/g, and kidney 290 ng/g. Cause of death was attributed to an acute sufentanil/midazolam intoxication and manner of death a suicide.
Integrated multiplexed capillary electrophoresis system
Yeung, Edward S.; Tan, Hongdong
2002-05-14
The present invention provides an integrated multiplexed capillary electrophoresis system for the analysis of sample analytes. The system integrates and automates multiple components, such as chromatographic columns and separation capillaries, and further provides a detector for the detection of analytes eluting from the separation capillaries. The system employs multiplexed freeze/thaw valves to manage fluid flow and sample movement. The system is computer controlled and is capable of processing samples through reaction, purification, denaturation, pre-concentration, injection, separation and detection in parallel fashion. Methods employing the system of the invention are also provided.
Wooding, Madelien; Rohwer, Egmont R; Naudé, Yvette
2017-05-05
Many rural dwellers and inhabitants of informal settlements in South Africa are without access to treated water and collect untreated water from rivers and dams for personal use. Endocrine disrupting chemicals (EDCs) have been detected in surface water and wildlife of South Africa. EDCs are often present in complex environmental matrices at ultra-trace levels complicating detection thereof. We report a simplified multi-residue approach for the detection and quantification of EDCs, emerging EDCs, and antiretroviral drugs in surface water. A low cost (less than one US dollar), disposable, sorptive extraction sampler was prepared in-house. The disposable samplers consisted of polydimethylsiloxane (PDMS) tubing fashioned into a loop which was then placed in water samples to concentrate EDCs and emerging pollutants. The PDMS samplers were thermally desorbed directly in the inlet of a GC, thereby eliminating the need for expensive consumable cryogenics. Comprehensive gas chromatography coupled to time-of-flight mass spectrometry (GC×GC-TOFMS) was used for compound separation and identification. Linear retention indices of EDCs and emerging pollutants were determined on a proprietary Crossbond ® phase Rtx ® -CLPesticides II GC capillary column. In addition, large volume injection of surface water into an ultra-performance liquid chromatograph tandem mass spectrometer (UPLC-MS/MS) was used as complementary methodology for the detection of less volatile compounds. Large volume injection reduced tedious and costly sample preparation steps. Limits of detection for the GC method ranged from 1 to 98pg/l and for the LC method from 2 to 135ng/l. Known and emerging EDCs such as pharmaceuticals, personal care products and pesticides, as well as the antiretroviral compounds, efavirenz and nevirapine, were detected in surface water from South Africa at concentration levels ranging from 0.16ng/l to 227ng/l. Copyright © 2017 Elsevier B.V. All rights reserved.
Zajicek, James L.; Tillitt, Donald E.; Huckins, James N.; Petty, Jimmie D.; Potts, Michael E.; Nardone, David A.
1996-01-01
Determination of PCBs in biological tissue extracts by enzyme-linked immunosorbent assays (ELISAs) can be problematic, since the hydrophobic solvents used for their extraction and isolation from interfering biochemicals have limited compatibility with the polar solvents (e.g. methanol/water) and the immunochemical reagents used in ELISA. Our studies of these solvent effects indicate that significant errors can occur when microliter volumes of PCB containing extracts, in hydrophobic solvents, are diluted directly into methanol/water diluents. Errors include low recovery and excess variability among sub-samples taken from the same sample dilution. These errors are associated with inhomogeneity of the dilution, which is readily visualized by the use of a hydrophobic dye, Solvent Blue 35. Solvent Blue 35 is also used to visualize the evaporative removal of hydrophobic solvent and the dissolution of the resulting PCB/dye residue by pure methanol and 50% (v/v) methanol/water, typical ELISA diluents. Evaporative removal of isooctane by an ambient temperature nitrogen purge with subsequent dissolution in 100% methanol gives near quantitative recovery of model PCB congeners. We also compare concentrations of total PCBs from ELISA (ePCB) to their corresponding concentrations determined from capillary gas chromatography (GC) in selected fish sample extracts and dialysates of semipermeable membrane device (SPMD) passive samplers using an optimized solvent exchange procedure. Based on Aroclor 1254 calibrations, ePCBs (ng/mL) determined in fish extracts are positively correlated with total PCB concentrations (ng/mL) determined by GC: ePCB = 1.16 * total-cPCB - 5.92. Measured ePCBs (ng/3 SPMDs) were also positively correlated (r2 = 0.999) with PCB totals (ng/3 SPMDs) measured by GC for dialysates of SPMDs: ePCB = 1.52 * total PCB - 212. Therefore, this ELISA system for PCBs can be a rapid alternative to traditional GC analyses for determination of PCBs in extracts of biota or in SPMD dialysates.
Grindstaff, Quirinus G.
1992-01-01
Described is a new gas chromatograph-mass spectrometer (GC/MS) system and method for quantitative analysis of reactive chemical compounds. All components of such a GC/MS system external to the oven of the gas chromatograph are programmably temperature controlled to operate at a volatilization temperature specific to the compound(s) sought to be separated and measured.
Bresciani, Francesca; Pietra, Marco; Corradini, Sara; Giunti, Massimo; Fracassi, Federico
2014-01-01
In human medicine, diagnosis of diabetic ketoacidosis (DKA) is usually based on measurement of capillary 3-β-hydroxybutyrate (3-HB) with a hand held ketone sensor. This study was conducted to determine if measurement of capillary 3-HB could be useful for the diagnosis and monitoring of canine DKA. Fifteen dogs with diabetic ketosis and 10 with DKA were evaluated. Paired measurements of 3-HB of capillary and venous blood samples were analysed by the electrochemical sensor and reference method. Use of capillary 3-HB measurement during DKA management was then evaluated through simultaneous measurements of capillary 3-HB, urinary AcAc and venous blood gas analysis. Good agreement between capillary and venous 3-HB measurement was detected by the electrochemical sensor and reference method. Monitoring treatment of DKA revealed a significant correlation between capillary 3-HB and acidosis markers, while no significant correlation was observed between AcAc and acidosis markers. A cut-off value of capillary blood 3-HB > 3.8 mmol/L for diagnosis of DKA resulted in 70% and 92% sensitivity and specificity. The electrochemical sensor accurately measures 3-HB concentration in both capillary and venous blood samples, is accurate in diagnosing canine DKA, and appears to reflect the patient's metabolic status during DKA treatment.
Gao, Boyan; Qin, Fang; Ding, Tingting; Chen, Yineng; Lu, Weiying; Yu, Liangli Lucy
2014-08-13
Ultraperformance liquid chromatography mass spectrometry (UPLC-MS), flow injection mass spectrometry (FIMS), and headspace gas chromatography (headspace-GC) combined with multivariate data analysis techniques were examined and compared in differentiating organically grown oregano from that grown conventionally. It is the first time that headspace-GC fingerprinting technology is reported in differentiating organically and conventionally grown spice samples. The results also indicated that UPLC-MS, FIMS, and headspace-GC-FID fingerprints with OPLS-DA were able to effectively distinguish oreganos under different growing conditions, whereas with PCA, only FIMS fingerprint could differentiate the organically and conventionally grown oregano samples. UPLC fingerprinting provided detailed information about the chemical composition of oregano with a longer analysis time, whereas FIMS finished a sample analysis within 1 min. On the other hand, headspace GC-FID fingerprinting required no sample pretreatment, suggesting its potential as a high-throughput method in distinguishing organically and conventionally grown oregano samples. In addition, chemical components in oregano were identified by their molecular weight using QTOF-MS and headspace-GC-MS.
Harley, William M; Kozar, Michael P; Fox, Alvin
2002-09-01
An automated derivatization instrument has been developed for the preparation of alditol acetates from bacterial hydrolysates for analysis by gas chromatography-mass spectrometry (GC-MS). The current report demonstrates the utility of the automated instrument for the more demanding task of trace analysis of muramic acid (Mur) in airborne dust using gas chromatography-tandem mass spectrometry (GC-MS(2)). Conditions for efficient derivatization of Mur, vital for trace analysis, are rigorous including lactam and imido group formation under anhydrous conditions. Furthermore, as the detection limit is lowered, possible contamination or carry-over of samples becomes an increasingly greater consideration and must not occur. The instrument meets these criteria and was successfully used for assaying the levels of Mur in laboratory air, which were found to be much lower than in the previous studies of heavily occupied schools and agricultural environments. The potential for GC-MS(3) in further lowering the detection limit was also demonstrated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This interim notice covers the following: extractable organic halides in solids, total organic halides, analysis by gas chromatography/Fourier transform-infrared spectroscopy, hexadecane extracts for volatile organic compounds, GC/MS analysis of VOCs, GC/MS analysis of methanol extracts of cryogenic vapor samples, screening of semivolatile organic extracts, GPC cleanup for semivolatiles, sample preparation for GC/MS for semi-VOCs, analysis for pesticides/PCBs by GC with electron capture detection, sample preparation for pesticides/PCBs in water and soil sediment, report preparation, Florisil column cleanup for pesticide/PCBs, silica gel and acid-base partition cleanup of samples for semi-VOCs, concentrate acid wash cleanup, carbon determination in solids using Coulometrics` CO{submore » 2} coulometer, determination of total carbon/total organic carbon/total inorganic carbon in radioactive liquids/soils/sludges by hot persulfate method, analysis of solids for carbonates using Coulometrics` Model 5011 coulometer, and soxhlet extraction.« less
Quantitative analysis of nailfold capillary morphology in patients with fibromyalgia
Choi, Dug-Hyun
2015-01-01
Background/Aims Nailfold capillaroscopy (NFC) has been used to examine morphological and functional microcirculation changes in connective tissue diseases. It has been demonstrated that NFC patterns reflect abnormal microvascular dynamics, which may play a role in fibromyalgia (FM) syndrome. The aim of this study was to determine NFC patterns in FM, and their association with clinical features of FM. Methods A total of 67 patients with FM, and 30 age- and sex-matched healthy controls, were included. Nailfold capillary patterns were quantitatively analyzed using computerized NFC. The parameters of interest were as follows: number of capillaries within the central 3 mm, deletion score, apical limb width, capillary width, and capillary dimension. Capillary dimension was determined by calculating the number of capillaries using the Adobe Photoshop version 7.0. Results FM patients had a lower number of capillaries and higher deletion scores on NFC compared to healthy controls (17.3 ± 1.7 vs. 21.8 ± 2.9, p < 0.05; 2.2 ± 0.9 vs. 0.7 ± 0.6, p < 0.05, respectively). Both apical limb width (µm) and capillary width (µm) were significantly decreased in FM patients (1.1 ± 0.2 vs. 3.7 ± 0.6; 5.4 ± 0.5 vs. 7.5 ± 1.4, respectively), indicating that FM patients have abnormally decreased digital capillary diameter and density. Interestingly, there was no difference in capillary dimension between the two groups, suggesting that the length or tortuosity of capillaries in FM patients is increased to compensate for diminished microcirculation. Conclusions FM patients had altered capillary density and diameter in the digits. Diminished microcirculation on NFC may alter capillary density and increase tortuosity. PMID:26161020
Castello, Lucía V; Galetto, Leonardo
2013-01-01
Tillandsia capillaris Ruiz & Pav., which belongs to the subgenus Diaphoranthema is distributed in Ecuador, Peru, Bolivia, northern and central Argentina, and Chile, and includes forms that are difficult to circumscribe, thus considered to form a complex. The entities of this complex are predominantly small-sized epiphytes, adapted to xeric environments. The most widely used classification defines 5 forms for this complex based on few morphological reproductive traits: Tillandsia capillaris Ruiz & Pav. f. capillaris, Tillandsia capillaris f. incana (Mez) L.B. Sm., Tillandsia capillaris f. cordobensis (Hieron.) L.B. Sm., Tillandsia capillaris f. hieronymi (Mez) L.B. Sm. and Tillandsia capillaris f. virescens (Ruiz & Pav.) L.B. Sm. In this study, 35 floral and vegetative characters were analyzed with a multivariate approach in order to assess and discuss different proposals for classification of the Tillandsia capillaris complex, which presents morphotypes that co-occur in central and northern Argentina. To accomplish this, data of quantitative and categorical morphological characters of flowers and leaves were collected from herbarium specimens and field collections and were analyzed with statistical multivariate techniques. The results suggest that the last classification for the complex seems more comprehensive and three taxa were delimited: Tillandsia capillaris (=Tillandsia capillaris f. incana-hieronymi), Tillandsia virescens s. str. (=Tillandsia capillaris f. cordobensis) and Tillandsia virescens s. l. (=Tillandsia capillaris f. virescens). While Tillandsia capillaris and Tillandsia virescens s. str. co-occur, Tillandsia virescens s. l. is restricted to altitudes above 2000 m in Argentina. Characters previously used for taxa delimitation showed continuous variation and therefore were not useful. New diagnostic characters are proposed and a key is provided for delimiting these three taxa within the complex.
Castello, Lucía V.; Galetto, Leonardo
2013-01-01
Abstract Tillandsia capillaris Ruiz & Pav., which belongs to the subgenus Diaphoranthema is distributed in Ecuador, Peru, Bolivia, northern and central Argentina, and Chile, and includes forms that are difficult to circumscribe, thus considered to form a complex. The entities of this complex are predominantly small-sized epiphytes, adapted to xeric environments. The most widely used classification defines 5 forms for this complex based on few morphological reproductive traits: Tillandsia capillaris Ruiz & Pav. f. capillaris, Tillandsia capillaris f. incana (Mez) L.B. Sm., Tillandsia capillaris f. cordobensis (Hieron.) L.B. Sm., Tillandsia capillaris f. hieronymi (Mez) L.B. Sm. and Tillandsia capillaris f. virescens (Ruiz & Pav.) L.B. Sm. In this study, 35 floral and vegetative characters were analyzed with a multivariate approach in order to assess and discuss different proposals for classification of the Tillandsia capillaris complex, which presents morphotypes that co-occur in central and northern Argentina. To accomplish this, data of quantitative and categorical morphological characters of flowers and leaves were collected from herbarium specimens and field collections and were analyzed with statistical multivariate techniques. The results suggest that the last classification for the complex seems more comprehensive and three taxa were delimited: Tillandsia capillaris (=Tillandsia capillaris f. incana-hieronymi), Tillandsia virescens s. str. (=Tillandsia capillaris f. cordobensis) and Tillandsia virescens s. l. (=Tillandsia capillaris f. virescens). While Tillandsia capillaris and Tillandsia virescens s. str. co-occur, Tillandsia virescens s. l. is restricted to altitudes above 2000 m in Argentina. Characters previously used for taxa delimitation showed continuous variation and therefore were not useful. New diagnostic characters are proposed and a key is provided for delimiting these three taxa within the complex. PMID:23805053
In silico analysis of stomach lineage specific gene set expression pattern in gastric cancer.
Pandi, Narayanan Sathiya; Suganya, Sivagurunathan; Rajendran, Suriliyandi
2013-10-04
Stomach lineage specific gene products act as a protective barrier in the normal stomach and their expression maintains the normal physiological processes, cellular integrity and morphology of the gastric wall. However, the regulation of stomach lineage specific genes in gastric cancer (GC) is far less clear. In the present study, we sought to investigate the role and regulation of stomach lineage specific gene set (SLSGS) in GC. SLSGS was identified by comparing the mRNA expression profiles of normal stomach tissue with other organ tissue. The obtained SLSGS was found to be under expressed in gastric tumors. Functional annotation analysis revealed that the SLSGS was enriched for digestive function and gastric epithelial maintenance. Employing a single sample prediction method across GC mRNA expression profiles identified the under expression of SLSGS in proliferative type and invasive type gastric tumors compared to the metabolic type gastric tumors. Integrative pathway activation prediction analysis revealed a close association between estrogen-α signaling and SLSGS expression pattern in GC. Elevated expression of SLSGS in GC is associated with an overall increase in the survival of GC patients. In conclusion, our results highlight that estrogen mediated regulation of SLSGS in gastric tumor is a molecular predictor of metabolic type GC and prognostic factor in GC. Copyright © 2013 Elsevier Inc. All rights reserved.
Survivin -31 G/C polymorphism might contribute to colorectal cancer (CRC) risk: a meta-analysis.
Yao, Linhua; Hu, Yi; Deng, Zhongmin; Li, Jingjing
2015-01-01
Published data has shown inconsistent findings about the association of survivin -31 G/C polymorphism with the risk of colorectal cancer (CRC). This meta-analysis quantitatively assesses the results from published studies to provide a more precise estimate of the association between survivin -31 G/C polymorphism as a possible predictor of the risk of CRC. We conducted a literature search in the PubMed, Web of Science, and Cochrane Library databases. Stata 12 software was used to calculate the pooled odds ratios (ORs) with 95% confidence intervals (CIs) based on the available data from each article. Six studies including 1840 cases with CRC and 1804 controls were included in this study. Survivin -31 G/C polymorphism was associated with a significantly increased risk of CRC (OR = 1.78; 95% CI, 1.53-2.07; I(2) = 0%). In the race subgroup analysis, both Asians (OR = 1.72; 95% CI, 1.44-2.05; I(2) = 0%) and Caucasians (OR = 1.93; 95% CI, 1.46-2.55; I(2) = 0%) with survivin -31 G/C polymorphism had increased CRC risk. In the subgroup analysis according to site of CRC, survivin -31 G/C polymorphism was not associated with colon cancer risk (OR = 2.02; 95% CI, 0.79-5.22; I(2) = 82%). However, this polymorphism was significantly associated with rectum cancer risk (OR = 1.98; 95% CI, 1.42-2.74; I(2) = 0%). In the subgroup analysis by clinical stage, both early stage (I+II) and advanced stage (III+IV) were associated with survivin -31 G/C polymorphism (OR = 1.61; 95% CI, 1.20-2.16; I(2) = 0% and OR = 2.30; 95% CI, 1.70-3.13; I(2) = 0%, respectively). In the subgroup analysis by smoke status, both smokers and non-smokers with survivin -31 G/C polymorphism showed increased CRC risk (OR = 1.47; 95% CI, 1.01-2.13; I(2) = 60% and OR = 1.71; 95% CI, 1.28-2.30; I(2) = 0%, respectively). In the subgroup analysis by drink status, both drinkers and non-drinkers with survivin -31 G/C polymorphism showed increased CRC risk (OR = 1.58; 95% CI, 1.06-2.37; I(2) = 8% and OR = 1.61; 95% CI, 1.23-2.11; I(2) = 0%, respectively). In conclusion, this meta-analysis suggested that survivin -31 G/C polymorphism may be associated with the risk of CRC.
Determining bruise etiology in muscle tissue using finite element analysis.
Tang, Kevin; Sharpe, Wyatt; Schulz, Alexandra; Tam, Edric; Grosse, Ian; Tis, John; Cullinane, Dennis
2014-03-01
Bruising, the result of capillary failure, is a common physical exam finding due to blunt trauma and, depending on location and severity, a potential indicator of abuse. Despite its clinical relevance, few studies have investigated the etiology of capillary failure. The goal of this study was to determine whether capillaries primarily fail under shear stress or hydraulic-induced tensile stress. An arteriole bifurcating into four capillaries was modeled using ANSYS 14.0 (®) . The capillaries were embedded in muscle tissue and a pressure of 20.4 kPa was applied. Any tensile stress exceeding 8.4 × 10(4) Pa was considered failure. Results showed that failure occurred directly under the impact zone and where capillaries bifurcated, rather than along the line of greatest shear stress, indicating that internal tensile stress is likely the primary mode of capillary failure in bruising. These results are supported by the concept that bruising can occur via blunt trauma in which no shearing lacerations occur. © 2013 American Academy of Forensic Sciences.
In silico analysis of stomach lineage specific gene set expression pattern in gastric cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pandi, Narayanan Sathiya, E-mail: sathiyapandi@gmail.com; Suganya, Sivagurunathan; Rajendran, Suriliyandi
Highlights: •Identified stomach lineage specific gene set (SLSGS) was found to be under expressed in gastric tumors. •Elevated expression of SLSGS in gastric tumor is a molecular predictor of metabolic type gastric cancer. •In silico pathway scanning identified estrogen-α signaling is a putative regulator of SLSGS in gastric cancer. •Elevated expression of SLSGS in GC is associated with an overall increase in the survival of GC patients. -- Abstract: Stomach lineage specific gene products act as a protective barrier in the normal stomach and their expression maintains the normal physiological processes, cellular integrity and morphology of the gastric wall. However,more » the regulation of stomach lineage specific genes in gastric cancer (GC) is far less clear. In the present study, we sought to investigate the role and regulation of stomach lineage specific gene set (SLSGS) in GC. SLSGS was identified by comparing the mRNA expression profiles of normal stomach tissue with other organ tissue. The obtained SLSGS was found to be under expressed in gastric tumors. Functional annotation analysis revealed that the SLSGS was enriched for digestive function and gastric epithelial maintenance. Employing a single sample prediction method across GC mRNA expression profiles identified the under expression of SLSGS in proliferative type and invasive type gastric tumors compared to the metabolic type gastric tumors. Integrative pathway activation prediction analysis revealed a close association between estrogen-α signaling and SLSGS expression pattern in GC. Elevated expression of SLSGS in GC is associated with an overall increase in the survival of GC patients. In conclusion, our results highlight that estrogen mediated regulation of SLSGS in gastric tumor is a molecular predictor of metabolic type GC and prognostic factor in GC.« less
FTIR gas chromatographic analysis of perfumes
NASA Astrophysics Data System (ADS)
Diederich, H.; Stout, Phillip J.; Hill, Stephen L.; Krishnan, K.
1992-03-01
Perfumes, natural or synthetic, are complex mixtures consisting of numerous components. Gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS) techniques have been extensively utilized for the analysis of perfumes and essential oils. A limited number of perfume samples have also been analyzed by FT-IR gas chromatographic (GC-FTIR) techniques. Most of the latter studies have been performed using the conventional light pipe (LP) based GC-FTIR systems. In recent years, cold-trapping (in a matrix or neat) GC-FTIR systems have become available. The cold-trapping systems are capable of sub-nanogram sensitivities. In this paper, comparison data between the LP and the neat cold-trapping GC- FTIR systems is presented. The neat cold-trapping interface is known as Tracer. The results of GC-FTIR analysis of some commercial perfumes is also presented. For comparison of LP and Tracer GC-FTIR systems, a reference (synthetic) mixture containing 16 major and numerous minor constituents was used. The components of the mixture are the compounds commonly encountered in commercial perfumes. The GC-FTIR spectra of the reference mixture was obtained under identical chromatographic conditions from an LP and a Tracer system. A comparison of the two sets of data thus generated do indeed show the enhanced sensitivity level of the Tracer system. The comparison also shows that some of the major components detected by the Tracer system were absent from the LP data. Closer examination reveals that these compounds undergo thermal decomposition on contact with the hot gold surface that is part of the LP system. GC-FTIR data were obtained for three commercial perfume samples. The major components of these samples could easily be identified by spectra search against a digitized spectral library created using the Tracer data from the reference mixture.
Comprehensive two-dimensional gas chromatography applied to illicit drug analysis.
Mitrevski, Blagoj; Wynne, Paul; Marriott, Philip J
2011-11-01
Multidimensional gas chromatography (MDGC), and especially its latest incarnation--comprehensive two-dimensional gas chromatography (GC × GC)--have proved advantageous over and above classic one-dimensional gas chromatography (1D GC) in many areas of analysis by offering improved peak capacity, often enhanced sensitivity and, especially in the case of GC × GC, the unique feature of 'structured' chromatograms. This article reviews recent advances in MDGC and GC × GC in drug analysis with special focus on ecstasy, heroin and cocaine profiling. Although 1D GC is still the method of choice for drug profiling in most laboratories because of its simplicity and instrument availability, GC × GC is a tempting proposition for this purpose because of its ability to generate a higher net information content. Effluent refocusing due to the modulation (compression) process, combined with the separation on two 'orthogonal' columns, results in more components being well resolved and therefore being analytically and statistically useful to the profile. The spread of the components in the two-dimensional plots is strongly dependent on the extent of retention 'orthogonality' (i.e. the extent to which the two phases possess different or independent retention mechanisms towards sample constituents) between the two columns. The benefits of 'information-driven' drug profiling, where more points of reference are usually required for sample differentiation, are discussed. In addition, several limitations in application of MDGC in drug profiling, including data acquisition rate, column temperature limit, column phase orthogonality and chiral separation, are considered and discussed. Although the review focuses on the articles published in the last decade, a brief chronological preview of the profiling methods used throughout the last three decades is given.
Neufeld, Lynnette; García-Guerra, Armando; Sánchez-Francia, Domingo; Newton-Sánchez, Oscar; Ramírez-Villalobos, María Dolores; Rivera-Dommarco, Juan
2002-01-01
To assess the comparability of hemoglobin concentration (Hb) in venous and capillary blood measured by Hemocue and an automated spectrophotometer (Celldyn) and to document the influence of type of blood (capillary or venous) and analysis method on anemia prevalence estimates. Between February and May 2000, capillary and venous samples were collected from 72 adults and children at Hospital del Niño Morelense (Morelos State Children's Hospital) in Cuernavaca, Morelos, Mexico, and assessed for Hb using the Hemocue and Celldyn methods. Estimated Hb levels were compared using the concordance correlation coefficient and Student's t test for paired data. The sensitivity and specificity for anemia diagnosis were estimated and compared between type of blood and method of assessment. Capillary blood had higher Hb (+0.5 g/dl) than venous blood in adults and children, as did samples assessed by Celldyn compared to Hemocue (+0.3 g/dl). Specificity to detect anemia was adequate (> 0.90) but sensitivity was low for capillary blood assessed by Hemocue (< 0.80). The difference in Hb between venous and capillary blood is likely related to biological variability. Hemoglobin concentration in capillary blood assessed by Hemocue provides an adequate estimation of population anemia prevalence but may result in excess false negative diagnoses among individuals. The results of this study stress the importance of sample collection technique, particularly for children. Method of analysis and sampling site need to be taken into consideration in field studies. The English version of this paper is available too at: http://www.insp.mx/salud/index.html.
NASA Astrophysics Data System (ADS)
Chen, Pengzhen; Wang, Xiaoqing; Liu, Li; Chong, Jinsong
2016-06-01
According to Bragg theory, capillary waves are the predominant scatterers of high-frequency band (such as Ka-band) microwave radiation from the surface of the ocean. Therefore, understanding the modulation mechanism of capillary waves is an important foundation for interpreting high-frequency microwave remote sensing images of the surface of the sea. In our experiments, we discovered that modulations of capillary waves are significantly larger than the values predicted by the classical theory. Further, analysis shows that the difference in restoring force results in an inflection point while the phase velocity changes from gravity waves region to capillary waves region, and this results in the capillary waves being able to resonate with gravity waves when the phase velocity of the gravity waves is equal to the group velocity of the capillary waves. Consequently, we propose a coupling modulation model in which the current modulates the capillary wave indirectly by modulating the resonant gravity waves, and the modulation of the former is approximated by that of the latter. This model very effectively explains the results discovered in our experiments. Further, based on Bragg scattering theory and this coupling modulation model, we simulate the modulation of normalized radar cross section (NRCS) of typical internal waves and show that the high-frequency bands are superior to the low-frequency bands because of their greater modulation of NRCS and better radiometric resolution. This result provides new support for choice of radar band for observation of wave-current modulation oceanic phenomena such as internal waves, fronts, and shears.
Effect of dispersion forces on the capillary-wave fluctuations of liquid surfaces.
Chacón, Enrique; Fernández, Eva M; Tarazona, Pedro
2014-04-01
We present molecular dynamics evidence for the nonanalytic effects of the long-range dispersion forces on the capillary waves fluctuations of a Lennard-Jones liquid surface. The results of the intrinsic sampling method, for the analysis of the instantaneous interfacial shape, are obtained in large systems for several cut-off distances of the potential tail, and they show good agreement with the theoretical prediction by Napiórkowski and Dietrich, based on a density functional analysis. The enhancement of the capillary waves is quantified to be within 1% for a simple liquid near its triple point.
Liu, Jingwei; He, Caiyun; Chen, Moye; Wang, Zhenning; Xing, Chengzhong; Yuan, Yuan
2013-11-20
There are increasing studies examining the relationship between the status of H. pylori oipA gene and peptic ulcer disease (PUD) and gastric cancer (GC) but the results turn out to be controversial. We attempted to clarify whether oipA gene status is linked with PUD and/or GC risks. A systematically literature search was performed through four electronic databases. According to the specific inclusion and exclusion criteria, seven articles were ultimately available for the meta-analysis of oipA presence/absence with PUD and GC, and eleven articles were included for the meta-analysis of oipA on/off status with PUD and GC. For the on/off functional status analysis of oipA gene, the "on" status showed significant associations with increased risks of PUD (OR = 3.97, 95% CI: 2.89, 5.45; P < 0.001) and GC (OR = 2.43, 95% CI: 1.45, 4.07; P = 0.001) compared with gastritis and functional dyspepsia controls. Results of the homogeneity test indicated different effects of oipA "on" status on PUD risk between children and adult subgroups and on GC risk between PCR-sequencing and immunoblot subgroups. For the presence/absence analysis of oipA gene, we found null association of the presence of oipA gene with the risks of PUD (OR = 1.93, 95% CI: 0.60, 6.25; P = 0.278) and GC (OR = 2.09, 95% CI: 0.51, 8.66; P = 0.308) compared with gastritis and functional dyspepsia controls. To be concluded, when oipA exists, the functional "on" status of this gene showed association with increased risks for PUD and GC compared with gastritis and FD controls. However, merely investigating the presence/absence of oipA would overlook the importance of its functional on/off status and would not be reliable to predict risks of PUD and GC. Further large-scale and well-designed studies concerning on/off status of oipA are required to confirm our meta-analysis results.
Urine Multi-drug Screening with GC-MS or LC-MS-MS Using SALLE-hybrid PPT/SPE.
Lee, Junhui; Park, Jiwon; Go, Ahra; Moon, Heesung; Kim, Sujin; Jung, Sohee; Jeong, Wonjoon; Chung, Heesun
2018-05-14
To intoxicated patients in the emergency room, toxicological analysis can be considerably helpful for identifying the involved toxicants. In order to develop a urine multi-drug screening (UmDS) method, gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS-MS) were used to determine targeted and unknown toxicants in urine. A GC-MS method in scan mode was validated for selectivity, limit of detection (LOD) and recovery. An LC-MS-MS multiple reaction monitoring (MRM) method was validated for lower LOD, recovery and matrix effect. The results of the screening analysis were compared with patient medical records to check the reliability of the screen. Urine samples collected from an emergency room were extracted through a combination of salting-out assisted liquid-liquid extraction (SALLE) and hybrid protein precipitation/solid phase extraction (hybrid PPT/SPE) plates and examined by GC-MS and LC-MS-MS. GC-MS analysis was performed as unknown drug screen and LC-MS-MS analysis was conducted as targeted drug screen. After analysis by GC-MS, a library search was conducted using an in-house library established with the automated mass spectral deconvolution and identification system (AMDISTM). LC-MS-MS used Cliquid®2.0 software for data processing and acquisition in MRM mode. An UmDS method by GC-MS and LC-MS-MS was developed by using a SALLE-hybrid PPT/SPE and in-house library. The results of UmDS by GC-MS and LC-MS-MS showed that toxicants could be identified from 185 emergency room patient samples containing unknown toxicants. Zolpidem, acetaminophen and citalopram were the most frequently encountered drugs in emergency room patients. The UmDS analysis developed in this study can be used effectively to detect toxic substances in a short time. Hence, it could be utilized in clinical and forensic toxicology practices.
NASA Astrophysics Data System (ADS)
Han, Bin; Lob, Silvia; Sablier, Michel
2018-06-01
In this study, we report the use of pyrolysis-GCxGC/MS profiles for an optimized treatment of data issued from pyrolysis-GC/MS combined with the automatic deconvolution software Automated Mass Spectral Deconvolution and Identification System (AMDIS). The method was illustrated by the characterization of marker compounds of East Asian handmade papers through the examination of pyrolysis-GCxGC/MS data to get information which was used for manually identifying low concentrated and co-eluting compounds in 1D GC/MS data. The results showed that the merits of a higher separation power for co-eluting compounds and a better sensitivity for low concentration compounds offered by a GCxGC system can be used effectively for AMDIS 1D GC/MS data treatment: (i) the compound distribution in pyrolysis-GCxGC/MS profiles can be used as "peak finder" for manual check of low concentration and co-eluting compound identification in 1D GC/MS data, and (ii) pyrolysis-GCxGC/MS profiles can provide better quality mass spectra with observed higher match factors in the AMDIS automatic match process. The combination of 2D profile with AMDIS was shown to contribute efficiently to a better characterization of compound profiles in the chromatograms obtained by 1D analysis in focusing on the mass spectral identification. [Figure not available: see fulltext.
Ptolemy, Adam S; Tran, Lara; Britz-McKibbin, Philip
2006-07-15
Capillary electrophoresis (CE) represents a versatile platform for integrating sample pretreatment with chemical analysis because of its ability to tune analyte electromigration and band dispersion properties in discontinuous electrolyte systems. In this article, a single-step method that combines on-line sample preconcentration with in-capillary chemical derivatization is developed for rapid, sensitive, and enantioselective analysis of micromolar levels of amino acids that lack intrinsic chromophores by CE with UV detection. Time-resolved electrophoretic studies revealed two distinct stages of amino acid band narrowing within the original long sample injection plug occurring both prior to and after in-capillary labeling via zone passing by ortho-phthalaldehyde/N-acetyl l-cysteine (OPA/NAC). This technique enabled direct analysis of d-amino acids in a 95% enantiomeric excess mixture with sub-micromolar detection limits and minimal sample handling, where the capillary functions as a preconcentrator, microreactor, and chiral selector. On-line sample preconcentration with chemical derivatization CE (SPCD-CE) was applied to study the enantioselective amino acid flux in Escherichia coli bacteria cultures, which demonstrated a unique l-Ala efflux into the extracellular medium. New strategies for high-throughput analyses of low-abundance metabolites are important for understanding fundamental physiological processes in bacteria required for screening the efficacy of new classes of antibiotics as well as altered metabolism in genetically modified mutant strains.
Miniaturized flow injection analysis system
Folta, J.A.
1997-07-01
A chemical analysis technique known as flow injection analysis is described, wherein small quantities of chemical reagents and sample are intermixed and reacted within a capillary flow system and the reaction products are detected optically, electrochemically, or by other means. A highly miniaturized version of a flow injection analysis system has been fabricated utilizing microfabrication techniques common to the microelectronics industry. The microflow system uses flow capillaries formed by etching microchannels in a silicon or glass wafer followed by bonding to another wafer, commercially available microvalves bonded directly to the microflow channels, and an optical absorption detector cell formed near the capillary outlet, with light being both delivered and collected with fiber optics. The microflow system is designed mainly for analysis of liquids and currently measures 38{times}25{times}3 mm, but can be designed for gas analysis and be substantially smaller in construction. 9 figs.
Structural and surface changes in glassy carbon due to strontium implantation and heat treatment
NASA Astrophysics Data System (ADS)
Odutemowo, O. S.; Malherbe, J. B.; Prinsloo, L. C.; Njoroge, E. G.; Erasmus, R.; Wendler, E.; Undisz, A.; Rettenmayr, M.
2018-01-01
There are still questions around the microstructure of glassy carbon (GC), like the observation of the micropores. These were proposed to explain the low density of GC. This paper explains the effect of ion bombardment (200 keV Sr+, 1 × 1016 Sr+/cm2 at RT) on the microstructure of GC. TEM and AFM show that micropores in pristine GC are destroyed leading to densification of GC from 1.42 g/cm3 to 2.03 g/cm3. The amorphisation of glassy carbon was also not complete with graphitic strands embedded within the GC. These were relatively few, as Raman analysis showed that the Sr implantation resulted in a typical amorphous Raman spectrum. Annealing of the sample at 900 °C only resulted in a slight recovery of the GC structure. AFM and SEM analysis showed that the surface of the sample became rougher after Sr implantation. The roughness increased after the sample was annealed at 600 °C due to segregation of Sr towards the surface of the GC. SEM measurements of a sample with both implanted and un-implanted edges after annealing at 900 °C, showed that the high temperature heat treatment did not affect the surface topography of un-irradiated GC.
Alu elements in primates are preferentially lost from areas of high GC content
Brookfield, John FY
2013-01-01
The currently-accepted dogma when analysing human Alu transposable elements is that ‘young’ Alu elements are found in low GC regions and ‘old’ Alus in high GC regions. The correlation between high GC regions and high gene frequency regions make this observation particularly difficult to explain. Although a number of studies have tackled the problem, no analysis has definitively explained the reason for this trend. These observations have been made by relying on the subfamily as a proxy for age of an element. In this study, we suggest that this is a misleading assumption and instead analyse the relationship between the taxonomic distribution of an individual element and its surrounding GC environment. An analysis of 103906 Alu elements across 6 human chromosomes was carried out, using the presence of orthologous Alu elements in other primate species as a proxy for age. We show that the previously-reported effect of GC content correlating with subfamily age is not reflected by the ages of the individual elements. Instead, elements are preferentially lost from areas of high GC content over time. The correlation between GC content and subfamily may be due to a change in insertion bias in the young subfamilies. The link between Alu subfamily age and GC region was made due to an over-simplification of the data and is incorrect. We suggest that use of subfamilies as a proxy for age is inappropriate and that the analysis of ortholog presence in other primate species provides a deeper insight into the data. PMID:23717800
Discriminating gastric cancer and gastric ulcer using human plasma amino acid metabolic profile.
Jing, Fangyu; Hu, Xin; Cao, Yunfeng; Xu, Minghao; Wang, Yuanyuan; Jing, Yu; Hu, Xiaodan; Gao, Yu; Zhu, Zhitu
2018-06-01
Patients with gastric ulcer (GU) have a significantly higher risk of developing gastric cancer (GC), especially within 2 years after diagnosis. The main way to improve the prognosis of GC is to predict the tumorigenesis and metastasis in the early stage. The objective of this study was to demonstrate the ability of human plasma amino acid metabolic profile for discriminating GC and GU. In this study, we first used liquid chromatography-tandem mass spectrometry technique to characterize the plasma amino acid metabolism in GC and GU patients. Plasma samples were collected from 84 GC patients and 82 GU patients, and 22 amino acids were detected in each patient. Partial least squares-discriminant analysis model was performed to analyze the data of these amino acids. We observed seven differential amino acids between GC and GU. A regression analysis model was established using these seven amino acids. Finally, a panel of five differential amino acids, including glutamine, ornithine, histidine, arginine and tryptophan, was identified for discriminating GC and GU with good specificity and sensitivity. The receiver operating characteristic curve was used to evaluate diagnostic ability of the regression model and area under the curve was 0.922. In conclusion, this study demonstrated the potential values of plasma amino acid metabolic profile and metabolomic analysis technique in assisting diagnosis of GC. More studies are needed to highlight the theoretical strengths of metabolomics to understand the potential metabolic mechanisms in GC. © 2018 IUBMB Life, 70(6):553-562, 2018. © 2018 International Union of Biochemistry and Molecular Biology.
Ullah, Md Ahsan; Kim, Ki-Hyun; Szulejko, Jan E; Cho, Jinwoo
2014-04-11
The production of short-chained volatile fatty acids (VFAs) by the anaerobic bacterial digestion of sewage (wastewater) affords an excellent opportunity to alternative greener viable bio-energy fuels (i.e., microbial fuel cell). VFAs in wastewater (sewage) samples are commonly quantified through direct injection (DI) into a gas chromatograph with a flame ionization detector (GC-FID). In this study, the reliability of VFA analysis by the DI-GC method has been examined against a thermal desorption (TD-GC) method. The results indicate that the VFA concentrations determined from an aliquot from each wastewater sample by the DI-GC method were generally underestimated, e.g., reductions of 7% (acetic acid) to 93.4% (hexanoic acid) relative to the TD-GC method. The observed differences between the two methods suggest the possibly important role of the matrix effect to give rise to the negative biases in DI-GC analysis. To further explore this possibility, an ancillary experiment was performed to examine bias patterns of three DI-GC approaches. For instance, the results of the standard addition (SA) method confirm the definite role of matrix effect when analyzing wastewater samples by DI-GC. More importantly, their biases tend to increase systematically with increasing molecular weight and decreasing VFA concentrations. As such, the use of DI-GC method, if applied for the analysis of samples with a complicated matrix, needs a thorough validation to improve the reliability in data acquisition. Copyright © 2014 Elsevier B.V. All rights reserved.
iGC-an integrated analysis package of gene expression and copy number alteration.
Lai, Yi-Pin; Wang, Liang-Bo; Wang, Wei-An; Lai, Liang-Chuan; Tsai, Mong-Hsun; Lu, Tzu-Pin; Chuang, Eric Y
2017-01-14
With the advancement in high-throughput technologies, researchers can simultaneously investigate gene expression and copy number alteration (CNA) data from individual patients at a lower cost. Traditional analysis methods analyze each type of data individually and integrate their results using Venn diagrams. Challenges arise, however, when the results are irreproducible and inconsistent across multiple platforms. To address these issues, one possible approach is to concurrently analyze both gene expression profiling and CNAs in the same individual. We have developed an open-source R/Bioconductor package (iGC). Multiple input formats are supported and users can define their own criteria for identifying differentially expressed genes driven by CNAs. The analysis of two real microarray datasets demonstrated that the CNA-driven genes identified by the iGC package showed significantly higher Pearson correlation coefficients with their gene expression levels and copy numbers than those genes located in a genomic region with CNA. Compared with the Venn diagram approach, the iGC package showed better performance. The iGC package is effective and useful for identifying CNA-driven genes. By simultaneously considering both comparative genomic and transcriptomic data, it can provide better understanding of biological and medical questions. The iGC package's source code and manual are freely available at https://www.bioconductor.org/packages/release/bioc/html/iGC.html .
Metabolomic analysis reveals altered metabolic pathways in a rat model of gastric carcinogenesis.
Gu, Jinping; Hu, Xiaomin; Shao, Wei; Ji, Tianhai; Yang, Wensheng; Zhuo, Huiqin; Jin, Zeyu; Huang, Huiying; Chen, Jiacheng; Huang, Caihua; Lin, Donghai
2016-09-13
Gastric cancer (GC) is one of the most malignant tumors with a poor prognosis. Alterations in metabolic pathways are inextricably linked to GC progression. However, the underlying molecular mechanisms remain elusive. We performed NMR-based metabolomic analysis of sera derived from a rat model of gastric carcinogenesis, revealed significantly altered metabolic pathways correlated with the progression of gastric carcinogenesis. Rats were histologically classified into four pathological groups (gastritis, GS; low-grade gastric dysplasia, LGD; high-grade gastric dysplasia, HGD; GC) and the normal control group (CON). The metabolic profiles of the five groups were clearly distinguished from each other. Furthermore, significant inter-metabolite correlations were extracted and used to reconstruct perturbed metabolic networks associated with the four pathological stages compared with the normal stage. Then, significantly altered metabolic pathways were identified by pathway analysis. Our results showed that oxidative stress-related metabolic pathways, choline phosphorylation and fatty acid degradation were continually disturbed during gastric carcinogenesis. Moreover, amino acid metabolism was perturbed dramatically in gastric dysplasia and GC. The GC stage showed more changed metabolite levels and more altered metabolic pathways. Two activated pathways (glycolysis; glycine, serine and threonine metabolism) substantially contributed to the metabolic alterations in GC. These results lay the basis for addressing the molecular mechanisms underlying gastric carcinogenesis and extend our understanding of GC progression.
[Is the use of plastic capillary tubes justified for blood gases analysis?].
Daurès, Marie-Françoise; Bozonnat, Marie-Cécile; Cristol, Jean-Paul
2011-01-01
Some clinical units, such as neonatal or maternity units, preferentially use capillary tubes when analysing blood gases. Using glass tubes is delicate and nurses must recollect blood when breaking. In order to eliminate this problem, we tested flexible, plastic capillary tubes in both the above mentionned units and in our biochemistry laboratory. Each unit, where glass tubes were habitually used, tested 200 flexible, plastic capillary tubes. In addition, the nursing staffed filled out a questionnaire concerned tube usage. Both units clearly preferred using the flexible tubes. In the laboratory, results for blood gas analyses were compared between rigid glass and flexible plastic capillary tubes for 112 patients. Concordance tests did not showed significant differences between the two tube types, except for hematocrit and total haemoglobin. A questionnaire was also presented to the lab technician, who confirmed the easier usability of plastic capillary tubes.
Fast, high temperature and thermolabile GC--MS in supersonic molecular beams
NASA Astrophysics Data System (ADS)
Dagan, Shai; Amirav, Aviv
1994-05-01
This work describes and evaluates the coupling of a fast gas chromatograph (GC) based on a short column and high carrier gas flow rate to a supersonic molecular beam mass spectrometer (MS). A 50 cm long megabore column serves for fast GC separation and connects the injector to the supersonic nozzle source. Sampling is achieved with a conventional syringe based splitless sample injection. The injector contains no septum and is open to the atmosphere. The linear velocity of the carrier gas is controlled by a by-pass (make-up) gas flow introduced after the column and prior to the supersonic nozzle. The supersonic expansion serves as a jet separator and the skimmed supersonic molecular beam (SMB) is highly enriched with the heavier organic molecules. The supersonic molecular beam constituents are ionized either by electron impact (EI) or hyperthermal surface ionization (HSI) and mass analyzed. A 1 s fast GC--MS of four aromatic molecules in methanol is demonstrated and some fundamental aspects of fast GC--MS with time limit constraints are outlined. The flow control (programming) of the speed of analysis is shown and the analysis of thermolabile and relatively non-volatile molecules is demonstrated and discussed. The tail-free, fast GC--MS of several mixtures is shown and peak tailing of caffeine is compared with that of conventional GC--MS. The improvement of the peak shapes with the SMB--MS is analyzed with the respect to the elimination of thermal vacuum chamber background. The extrapolated minimum detected amount was about 400 ag of anthracence-d10, with an elution time which was shorter than 2s. Repetitive injections could be performed within less than 10 s. The fast GC--MS in SMB seems to be ideal for fast target compound analysis even in real world, complex mixtures. The few seconds GC--MS separation and quantification of lead (as tetraethyllead) in gasoline, caffeine in coffee, and codeine in a drug is demonstrated. Controlled HSI selectivity is demonstrated in the range of 101 to 104 anthracene/decane which helped to simplify the selective analysis of aromatic molecules in gasoline. The contribution of SMB to the operation of the fast GC--MS is summarized and the compatibility with conventional GC having a megabore column is shown. Splitless injections of 100 [mu]L sample solutions for trace level concentration detection is also presented (with a conventional GC).
Capillary toroid cavity detector for high pressure NMR
Gerald, II, Rex E.; Chen, Michael J.; Klingler, Robert J.; Rathke, Jerome W.; ter Horst, Marc
2007-09-11
A Toroid Cavity Detector (TCD) is provided for implementing nuclear magnetic resonance (NMR) studies of chemical reactions under conditions of high pressures and temperatures. A toroid cavity contains an elongated central conductor extending within the toroid cavity. The toroid cavity and central conductor generate an RF magnetic field for NMR analysis. A flow-through capillary sample container is located within the toroid cavity adjacent to the central conductor to subject a sample material flowing through the capillary to a static magnetic field and to enable NMR spectra to be recorded of the material in the capillary under a temperature and high pressure environment.
RASA1 analysis guides management in a family with capillary malformation-arteriovenous malformation
Flore, Leigh Anne; Leon, Eyby; Maher, Tom A.; Milunsky, Jeff M.
2012-01-01
Capillary malformation-arteriovenous malformation (CM-AVM; MIM 60354) is an autosomal dominant disorder characterized by multifocal cutaneous capillary malformations, often in association with fast-flow vascular lesions, which may be cutaneous, subcutaneous, intramuscular, intraosseus, or cerebral arteriovenous malformations or arteriovenous fistulas. CM-AVM results from heterozygous mutations in the RASA1 gene. Capillary malformations of the skin are common, and clinical examination alone may not be able to definitively diagnose-or exclude- CM-AVM. We report a family in which the proband was initially referred for a genetic evaluation in the neonatal period because of the presence of a cardiac murmur and minor dysmorphic features. Both he and his mother were noted to have multiple capillary malformations on the face, head, and extremities. Echocardiography revealed dilated head and neck vessels and magnetic resonance imaging and angiography of the brain revealed a large infratentorial arteriovenous fistula, for which he has had two embolization procedures. RASA1 sequence analysis revealed a heterozygous mutation, confirming his diagnosis of CM-AVM. We established targeted mutation analysis for the proband's mother and sister, the latter of whom is a healthy 3-year-old whose only cutaneous finding is a facial capillary malformation. This revealed that the proband's mother is also heterozygous for the RASA1 mutation, but his sister is negative. Consequently, his mother will undergo magnetic resonance imaging and angiography screening for intracranial and spinal fast-flow lesions, while his sister will require no imaging or serial evaluations. Targeted mutation analysis has been offered to additional maternal family members. This case illustrates the benefit of molecular testing in diagnosis and making screening recommendations for families with CM-AVM. PMID:27625812
RASA1 analysis guides management in a family with capillary malformation-arteriovenous malformation.
Flore, Leigh Anne; Leon, Eyby; Maher, Tom A; Milunsky, Jeff M
2012-06-01
Capillary malformation-arteriovenous malformation (CM-AVM; MIM 60354) is an autosomal dominant disorder characterized by multifocal cutaneous capillary malformations, often in association with fast-flow vascular lesions, which may be cutaneous, subcutaneous, intramuscular, intraosseus, or cerebral arteriovenous malformations or arteriovenous fistulas. CM-AVM results from heterozygous mutations in the RASA1 gene. Capillary malformations of the skin are common, and clinical examination alone may not be able to definitively diagnose-or exclude- CM-AVM. We report a family in which the proband was initially referred for a genetic evaluation in the neonatal period because of the presence of a cardiac murmur and minor dysmorphic features. Both he and his mother were noted to have multiple capillary malformations on the face, head, and extremities. Echocardiography revealed dilated head and neck vessels and magnetic resonance imaging and angiography of the brain revealed a large infratentorial arteriovenous fistula, for which he has had two embolization procedures. RASA1 sequence analysis revealed a heterozygous mutation, confirming his diagnosis of CM-AVM. We established targeted mutation analysis for the proband's mother and sister, the latter of whom is a healthy 3-year-old whose only cutaneous finding is a facial capillary malformation. This revealed that the proband's mother is also heterozygous for the RASA1 mutation, but his sister is negative. Consequently, his mother will undergo magnetic resonance imaging and angiography screening for intracranial and spinal fast-flow lesions, while his sister will require no imaging or serial evaluations. Targeted mutation analysis has been offered to additional maternal family members. This case illustrates the benefit of molecular testing in diagnosis and making screening recommendations for families with CM-AVM.
Nailfold capillary patterns in healthy subjects: a real issue in capillaroscopy.
Ingegnoli, Francesca; Gualtierotti, Roberta; Lubatti, Chiara; Bertolazzi, Chiara; Gutierrez, Marwin; Boracchi, Patrizia; Fornili, Marco; De Angelis, Rossella
2013-11-01
Nailfold capillaroscopy has been extensively applied in a broad spectrum of pathologic conditions, but very few data have been published in healthy individuals. The aim of this study was to describe the nailfold capillary findings on a large series of healthy subjects using the video-capillaroscopy technique. Nailfold capillaries were studied based on their morphology, dimensions and density. Then, to evaluate jointly the association between different capillary findings in groups of subjects which were homogeneous for their characteristics, cluster analysis was performed. The results (median) of capillary measurements were as follows: loop length 207μm, external diameter 39μm, internal diameter 17μm, apical diameter 17μm, and intercapillary distance 143μm. Based on the cluster analysis three major "normal" morphologic capillaroscopic patterns were depicted: 1) the "normal" pattern mainly with 2 to 5 U-shaped loops/mm and ≤2 tortuous loops/mm; 2) the "perfect normal" pattern with ≥5 U-shaped loops/mm and 3) the "unusual normal" with at least 1 meandering or bushy loop, or at least 1 microhemorrhage, or with >4 crossed loops/mm. Regarding the loop measurements, the majority of subjects had a median of 7capillaries/mm with a median length of 198μm. © 2013 Elsevier Inc. All rights reserved.
Cappelli Fontanive, Fernando; Souza-Silva, Érica Aparecida; Macedo da Silva, Juliana; Bastos Caramão, Elina; Alcaraz Zini, Claudia
2016-08-26
Diesel and naphtha samples were analyzed using ionic liquid (IL) columns to evaluate the best column set for the investigation of organic sulfur compounds (OSC) and nitrogen(N)-containing compounds analyses with comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry detector (GC×GC/TOFMS). Employing a series of stationary phase sets, namely DB-5MS/DB-17, DB-17/DB-5MS, DB-5MS/IL-59, and IL-59/DB-5MS, the following parameters were systematically evaluated: number of tentatively identified OSC, 2D chromatographic space occupation, number of polyaromatic hydrocarbons (PAH) and OSC co-elutions, and percentage of asymmetric peaks. DB-5MS/IL-59 was chosen for OSC analysis, while IL59/DB-5MS was chosen for nitrogen compounds, as each stationary phase set provided the best chromatographic efficiency for these two classes of compounds, respectively. Most compounds were tentatively identified by Lee and Van den Dool and Kratz retention indexes, and spectra-matching to library. Whenever available, compounds were also positively identified via injection of authentic standards. Copyright © 2016 Elsevier B.V. All rights reserved.
Source, impact and removal of malodour from soiled clothing.
Denawaka, Chamila J; Fowlis, Ian A; Dean, John R
2016-03-18
Static headspace--multi-capillary column--gas chromatography--ion mobility spectrometry (SHS-MCC-GC-IMS) has been applied to the analysis of malodour compounds from soiled clothing (socks and T-shirts), pre- and post washing, at low temperature (20°C). Six volatile compounds (VCs) (i.e. butyric acid, dimethyl disulfide, dimethyl trisulfide, 2-heptanone, 2-nonanone and 2-octanone) were identified. After sensory evaluation of soiled garments they were subjected to laundering with non-perfumed washing powder. The efficiency of the laundering process was evaluated by determining the reduction of each detected volatile compound (VC) post-wash (damp) for socks and T-shirts; VC concentration reductions of between 16 and 100% were noted, irrespective of sample type. Additionally the T-shirt study considered the change in VC concentration post-wash (dry) i.e. after the drying process at ambient temperature. Overall VC concentration reductions of between 25 and 98% were noted for T-shirt samples pre-wash to post-wash (dry). Finally, a potential biochemical metabolic pathway for the formation of malodour compounds associated with bacteria in axillary sweat is proposed. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Thin layer chromatography-ion mobility spectrometry (TLC-IMS).
Ilbeigi, Vahideh; Tabrizchi, Mahmoud
2015-01-06
Ion mobility spectrometry (IMS) is a fast and sensitive analytical method which operates at the atmospheric pressure. To enhance the capability of IMS for the analysis of mixtures, it is often used with preseparation techniques, such as GC or HPLC. Here, we report for the first time the coupling of the thin-layer chromatography and IMS. A variety of coupling schemes were tried that included direct electrospray from the TLC strip tip, indirect electrospray from a needle connected to the TLC strip, introducing the moving solvent into the injection port, and, the simplest way, offline introduction of scratched or cut pieces of strips into the IMS injection port. In this study a special solvent tank was designed and the TLC strip was mounted horizontally where the solvent would flow down. A very small funnel right below the TLC tip collected the solvent and transferred it to a needle via a capillary tubing. Using the TLC-ESI-IMS technique, acceptable separations were achieved for two component mixtures of morphine-papaverine and acridine-papaverine. A special injection port was designed to host the pieces cut off the TLC. The method was successfully used to identify each spot on the TLC by IMS in a few seconds.
Villa, C; Trucchi, B; Bertoli, A; Pistelli, L; Parodi, A; Bassi, A M; Ruffoni, B
2009-02-01
Salvia somalensis Vatke, a wild sage native of Somalia, has been studied with the aim of assessing the potential cosmetic application of its essential oil, recovered from fresh aerial parts by solvent-free microwave extraction - SFME. To evaluate the efficiency and reliability of this eco-friendly procedure, the recovery of the essential oil was also processed by conventional hydrodistillation (HD) and the results compared. The essential oils obtained by both SFME and HD were analysed by gas chromatography-mass spectrometry using apolar and polar capillary columns. The essential oil recovered by SFME was submitted to an odour evaluation that revealed peculiar olfactive characteristics interesting in alcoholic male perfumery and body detergents.In vitro cytotoxicity assays were carried out using NCTC 2544 human keratinocytes as target cells. The oil displayed slight cytotoxic effects, which were three orders of magnitude lower than those found for sodium dodecyl sulphate positive control. The promising results in terms of chemical composition, scent and safety seem to indicate this essential oil as an interesting potential functional ingredient useful in a cosmetic context.
NASA Technical Reports Server (NTRS)
Kong, Suk Bin
2001-01-01
Volatile organic compound(VOC), ethylene gas, was characterized and quantified by GC/FID. 20-50 ppb levels were detected during the growth stages of radish. SPME could be a good analytical tool for the purpose. Low temperature trapping method using dry ice/diethyl ether and liquid nitrogen bath was recommended for the sampling process for GC/PID and GC/MS analysis.
Watson, Nathanial E; Prebihalo, Sarah E; Synovec, Robert E
2017-08-29
Comprehensive three-dimensional gas chromatography with time-of-flight mass spectrometry (GC 3 -TOFMS) creates an opportunity to explore a new paradigm in chemometric analysis. Using this newly described instrument and the well understood Parallel Factor Analysis (PARAFAC) model we present one option for utilization of the novel GC 3 -TOFMS data structure. We present a method which builds upon previous work in both GC 3 and targeted analysis using PARAFAC to simplify some of the implementation challenges previously discovered. Conceptualizing the GC 3 -TOFMS instead as a one-dimensional gas chromatograph with GC × GC-TOFMS detection we allow the instrument to create the PARAFAC target window natively. Each first dimension modulation thus creates a full GC × GC-TOFMS chromatogram fully amenable to PARAFAC. A simple mixture of 115 compounds and a diesel sample are interrogated through this methodology. All test analyte targets are successfully identified in both mixtures. In addition, mass spectral matching of the PARAFAC loadings to library spectra yielded results greater than 900 in 40 of 42 test analyte cases. Twenty-nine of these cases produced match values greater than 950. Copyright © 2017 Elsevier B.V. All rights reserved.
Zhao, Xiangwei; Xue, Jiangyang; Mu, Zhongde; Huang, Yin; Lu, Meng; Gu, Zhongze
2015-10-15
Novel transducers are needed for point of care testing (POCT) devices which aim at facile, sensitive and quick acquisition of health related information. Recent advances in optofluidics offer tremendous opportunities for biological/chemical analysis using extremely small sample volumes. This paper demonstrates nanostructured capillary tubes for surface enhanced Raman spectroscopy (SERS) analysis in a flow-through fashion. The capillary tube integrates the SERS sensor and the nanofluidic structure to synergistically offer sample delivery and analysis functions. Inside the capillary tube, inverse opal photonic crystal (IO PhC) was fabricated using the co-assembly approach to form nanoscale liquid pathways. In the nano-voids of the IO PhC, gold nanoparticles were in situ synthesized and functioned as the SERS hotspots. The advantages of the flow-through SERS sensor are multifold. The capillary effect facilities the sample delivery process, the nanofluidic channels boosts the interaction of analyte and gold nanoparticles, and the PhC structure strengthens the optical field near the SERS hotspots and results in enhanced SERS signals from analytes. As an exemplary demonstration, the sensor was used to measure creatinein spiked in artificial urine samples with detection limit of 0.9 mg/dL. Copyright © 2015 Elsevier B.V. All rights reserved.
Native and sodium dodecyl sulfate-capillary gel electrophoresis of proteins on a single microchip.
Tsai, Shuo-Wen; Loughran, Michael; Suzuki, Hiroaki; Karube, Isao
2004-02-01
Simultaneous electrophoresis of both native and Sodium dodecyl sulfate (SDS) proteins was observed on a single microchip within 20 min. The capillary array prevented lateral diffusion of SDS components and avoided cross contamination of native protein samples. The planar sputtered electrode format provided a more uniform distribution of separation voltage into each of the 36 parallel microchannel capillaries than platinum wire electrodes commonly used in conventional electrophoresis. The customized geometry of the stacking capillary machined into the cover plate of the microchip facilitated reproducible sample injection without the requirement for stacking gel. Polyimide served as a mask and facilitated insulation of the anode and cathode to prevent electrode lift off and deterioration during continuous electrophoresis, even at a constant current of 8 mA. Improved protein separation was observed during capillary electrophoresis at lower currents. Ferguson plot analysis confirmed the electrophoretic mobility of native globular proteins in accordance with their charge and size. Corresponding Ferguson plot analysis of SDS-associated proteins on the same chip confirmed separation of marker proteins according to their molecular weight.
Publications - GMC 385 | Alaska Division of Geological & Geophysical
DGGS GMC 385 Publication Details Title: Porosity, permeability, and capillary pressure core analysis Shimer, G., 2011, Porosity, permeability, and capillary pressure core analysis results (2,124'-2,193 -capilar.xls (108.0 K) gmc385-cores-water.xls (19.0 K) Keywords Oil and Gas; Permeability; Porosity Top of Page
Zarghani, Maryam; Parastar, Hadi
2017-11-17
The objective of the present work is development of joint approximate diagonalization of eigenmatrices (JADE) as a member of independent component analysis (ICA) family, for the analysis of gas chromatography-mass spectrometry (GC-MS) and comprehensive two-dimensional gas chromatography-mass spectrometry (GC×GC-MS) data to address incomplete separation problem occurred during the analysis of complex sample matrices. In this regard, simulated GC-MS and GC×GC-MS data sets with different number of components, different degree of overlap and noise were evaluated. In the case of simultaneous analysis of multiple samples, column-wise augmentation for GC-MS and column-wise super-augmentation for GC×GC-MS was used before JADE analysis. The performance of JADE was evaluated in terms of statistical parameters of lack of fit (LOF), mutual information (MI) and Amari index as well as analytical figures of merit (AFOMs) obtained from calibration curves. In addition, the area of feasible solutions (AFSs) was calculated by two different approaches of MCR-BANDs and polygon inflation algorithm (FACPACK). Furthermore, JADE performance was compared with multivariate curve resolution-alternating least squares (MCR-ALS) and other ICA algorithms of mean-field ICA (MFICA) and mutual information least dependent component analysis (MILCA). In all cases, JADE could successfully resolve the elution and spectral profiles in GC-MS and GC×GC-MS data with acceptable statistical and calibration parameters and their solutions were in AFSs. To check the applicability of JADE in real cases, JADE was used for resolution and quantification of phenanthrene and anthracene in aromatic fraction of heavy fuel oil (HFO) analyzed by GC×GC-MS. Surprisingly, pure elution and spectral profiles of target compounds were properly resolved in the presence of baseline and interferences using JADE. Once more, the performance of JADE was compared with MCR-ALS in real case. On this matter, the mutual information (MI) values were 1.01 and 1.13 for resolved profiles by JADE and MCR-ALS, respectively. In addition, LOD values (μg/mL) were respectively 1.36 and 1.24 for phenanthrene and 1.26 and 1.09 for anthracene using MCR-ALS and JADE which showed outperformance of JADE over MCR-ALS. Copyright © 2017 Elsevier B.V. All rights reserved.
Annual Quality Assurance Conference Presentations by Michelle Misselwitz
25th Annual Quality Assurance Conference. Presentations: Tools I Can’t Live Without: Speed Up Method Development and Translation, Essentials for GC and GC/MS Users; Tricks of the Trade, Keeping Your GC System Up Longer for the Analysis of Pesticides
Pouillot, Régis; Van Doren, Jane M; Woods, Jacquelina; Plante, Daniel; Smith, Mark; Goblick, Gregory; Roberts, Christopher; Locas, Annie; Hajen, Walter; Stobo, Jeffrey; White, John; Holtzman, Jennifer; Buenaventura, Enrico; Burkhardt, William; Catford, Angela; Edwards, Robyn; DePaola, Angelo; Calci, Kevin R
2015-07-01
Human norovirus (NoV) is the leading cause of foodborne illness in the United States and Canada. Wastewater treatment plant (WWTP) effluents impacting bivalve mollusk-growing areas are potential sources of NoV contamination. We have developed a meta-analysis that evaluates WWTP influent concentrations and log10 reductions of NoV genotype I (NoV GI; in numbers of genome copies per liter [gc/liter]), NoV genotype II (NoV GII; in gc/liter), and male-specific coliphage (MSC; in number of PFU per liter), a proposed viral surrogate for NoV. The meta-analysis included relevant data (2,943 measurements) reported in the scientific literature through September 2013 and previously unpublished surveillance data from the United States and Canada. Model results indicated that the mean WWTP influent concentration of NoV GII (3.9 log10 gc/liter; 95% credible interval [CI], 3.5, 4.3 log10 gc/liter) is larger than the value for NoV GI (1.5 log10 gc/liter; 95% CI, 0.4, 2.4 log10 gc/liter), with large variations occurring from one WWTP to another. For WWTPs with mechanical systems and chlorine disinfection, mean log10 reductions were -2.4 log10 gc/liter (95% CI, -3.9, -1.1 log10 gc/liter) for NoV GI, -2.7 log10 gc/liter (95% CI, -3.6, -1.9 log10 gc/liter) for NoV GII, and -2.9 log10 PFU per liter (95% CI, -3.4, -2.4 log10 PFU per liter) for MSCs. Comparable values for WWTPs with lagoon systems and chlorine disinfection were -1.4 log10 gc/liter (95% CI, -3.3, 0.5 log10 gc/liter) for NoV GI, -1.7 log10 gc/liter (95% CI, -3.1, -0.3 log10 gc/liter) for NoV GII, and -3.6 log10 PFU per liter (95% CI, -4.8, -2.4 PFU per liter) for MSCs. Within WWTPs, correlations exist between mean NoV GI and NoV GII influent concentrations and between the mean log10 reduction in NoV GII and the mean log10 reduction in MSCs. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Li, Daojin; Yin, Danyang; Chen, Yang; Liu, Zhen
2017-05-19
Protein phosphorylation is a major post-translational modification, which plays a vital role in cellular signaling of numerous biological processes. Mass spectrometry (MS) has been an essential tool for the analysis of protein phosphorylation, for which it is a key step to selectively enrich phosphopeptides from complex biological samples. In this study, metal-organic frameworks (MOFs)-based monolithic capillary has been successfully prepared as an effective sorbent for the selective enrichment of phosphopeptides and has been off-line coupled with matrix-assisted laser desorption ionization-time-of-flight mass spectrometry (MALDI-TOF MS) for efficient analysis of phosphopeptides. Using š-casein as a representative phosphoprotein, efficient phosphorylation analysis by this off-line platform was verified. Phosphorylation analysis of a nonfat milk sample was also demonstrated. Through introducing large surface areas and highly ordered pores of MOFs into monolithic column, the MOFs-based monolithic capillary exhibited several significant advantages, such as excellent selectivity toward phosphopeptides, superb tolerance to interference and simple operation procedure. Because of these highly desirable properties, the MOFs-based monolithic capillary could be a useful tool for protein phosphorylation analysis. Copyright © 2016 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parsons, Brendon A.; Marney, Luke C.; Siegler, William C.
Multi-dimensional chromatographic instrumentation produces information-rich, and chemically complex data containing meaningful chemical signals and/or chemical patterns. Two-dimensional gas chromatography coupled with time-of-flight mass spectrometry (GC × GC – TOFMS) is a prominent instrumental platform that has been applied extensively for discovery-based experimentation, where samples are sufficiently volatile or amenable to derivatization. Use of GC × GC – TOFMS and associated data analysis strategies aim to uncover meaningful chemical signals or chemical patterns. However, for complex samples, meaningful chemical information is often buried in a background of less meaningful chemical signal and noise. In this report, we utilize the tile-based F-ratiomore » software in concert with the standard addition method by spiking non-native chemicals into a diesel fuel matrix at low concentrations. While the previous work studied the concentration range of 100-1000 ppm, the current study focuses on the 0 ppm to 100 ppm analyte spike range. This study demonstrates the sensitivity and selectivity of the tile-based F-ratio software for discovery of true positives in the non-targeted analysis of a chemically complex and analytically challenging sample matrix. By exploring the low concentration spike levels, we gain a better understanding of the limit of detection (LOD) of the tile-based F-ratio software with GC × GC – TOFMS data.« less
Kahle, Claudia; Holzgrabe, Ulrike
2004-10-01
Cyclodextrins are well known for their ability to separate enantiomers of drugs, natural products, and other chiral substances using HPLC, GC, or CE. The resolution of the enantiomers is due to the formation of diastereomeric complexes between the cyclodextrin and the pairs of enantiomers. The aim of this study was to determine the binding constants of the complexes between alpha- and beta-cyclodextrin and the enantiomers of a series of aliphatic and aromatic amino acids, and dipeptides, using a potentiometric titration method. The results of this method are compared to other methods, and correlated to findings in cyclodextrin-modified capillary electrophoresis and possible complex structures. Potentiometric titration was found to be an appropriate tool to determine the binding constants of cyclodextrin inclusion complexes.
Zero dead volume tube to surface seal
Benett, William J.; Folta, James A.
2000-01-01
A method and apparatus for connecting a tube to a surface that creates a dead volume seal. The apparatus is composed of three components, a body, a ferrule, and a threaded fitting. The ferrule is compressed onto a tube and a seal is formed between the tube and a device retained in the body by threading the fitting into the body which provides pressure that seals the face of the ferrule to a mating surface on the device. This seal can be used at elevated temperatures depending on the materials used. While the invention has been developed for use with micro-machined silicon wafers used in Capillary Gas Chromatograph (GC), it can be utilized anywhere for making a gas or fluid face seal to the surface of a device that has near zero dead volume.
Volatiles of Helichrysum italicum (Roth) G. Don from Croatia.
Zeljković, Sanja Ćavar; Šolić, Marija Edita; Maksimović, Milka
2015-01-01
Helichrysum italicum (Roth) G. Don is a flowering plant of the family Asteraceae. It is rich in oil that is used for different medicinal purposes and in fragrance industry. Volatile profile of four populations of H. italicum, collected from natural habitat in Dalmatia (Croatia), was analysed by capillary GC-MS. Sample from BraČ Island had α-trans-bergamotene (10.2%) and β-acoradiene (10.1%) as the majors, whereas sample collected on Biokovo Mt. was rich in neryl acetate (8.1%). β-Acoradiene was also the main constituent of sample collected near Tijarica, whereas rosifoliol (8.5%) was the most abundant constituent in sample collected near Makarska. Presented results show the influence of environmental conditions on chemical differentiation of the volatiles of H. italicum from Croatia.
Hu, Haobin; Zheng, Xudong; Hu, Huaisheng
2012-09-01
The leaf essential oil of Acanthopanax leucorrhizus, a widely used medicinal plant, was obtained by hydrodistillation and analyzed by using combination of capillary GC-FID, GC-MS and RI. Fifty-nine components, representing 93.1% of the total oil, were identified in the essential oil and the main components of the oil were β-pinene (7.3%), linalool (6.5%), p-cymene (6.3%), β-elemene (3.8%), γ-terpinene (3.7%), spathulenol (3.2%) and cis-sabinene hydrate (3.1%). Furthermore, the in vitro antimicrobial, antioxidant and cytotoxic activities of the essential oil were examined. The test results showed that the essential oil exhibited a broad spectrum of anti-microbial activity against all microorganisms tested. Gram-positive bacteria were more sensitive to the oil than gram-negative bacteria and yeasts. The oil possessed moderate cytotoxicity on human tumor cells with lower IC(50) values of 25.65μg/ml (Hep G2), 28.71μg/ml (Hela), 30.15μg/ml (Bel-7402) and 37.55μg/ml (A-549). The moderate antioxidant activity of the oil was also evaluated by the 1,1-diphenyl-2-picrylhydrazyl (DPPH) radical method. Copyright © 2012 Elsevier B.V. All rights reserved.
Monitoring of pesticide residues in vegetarian diet.
Kumari, Beena; Kathpal, T S
2009-04-01
Samples (28) of complete vegetarian diet consumed from morning till night i.e. tea, milk, breakfast, lunch, snacks, dinner, sweet dish etc. were collected from homes, hostels and hotels periodically from Hisar and analysed for detecting the residues of organochlorine, synthetic pyrethriod, organophosphate and carbamate insecticides. The estimation was carried out by using multi-residue analytical technique employing gas chromatograph (GC)-electron capture detector and GC-nitrogen phosphorous detector systems equipped with capillary columns. The whole diet sample was macerated in a mixer grinder and a representative sample in duplicate was analyzed for residues keeping the average daily diet of an adult to be 1,300 g. On comparing the data, it was found that actual daily intake (microgram/person/day) of lindane in two and endosulfan in four samples exceeded the acceptable daily intake. Residues of other pesticides in all the diet samples were lower than the acceptable daily intake (ADI) of the respective pesticides. The study concluded that although all the diet samples were found contaminated with one or the other pesticide, the actual daily intake of only a few pesticides was higher than their respective ADI. More extensive study covering other localities of Haryana has been suggested to know the overall scenario of contamination of vegetarian diet.
Jiang, Hua; Yang, Jing; Fan, Li; Li, Fengmin; Huang, Qiliang
2013-01-01
The toxic inert ingredients in pesticide formulations are strictly regulated in many countries. In this paper, a simple and efficient headspace-gas chromatography-mass spectrometry (HSGC-MS) method using fluorobenzene as an internal standard (IS) for rapid simultaneous determination of benzene and toluene in pesticide emulsifiable concentrate (EC) was established. The headspace and GC-MS conditions were investigated and developed. A nonpolar fused silica Rtx-5 capillary column (30 m × 0.20 mm i.d. and 0.25 μm film thickness) with temperature programming was used. Under optimized headspace conditions, equilibration temperature of 120°C, equilibration time of 5 min, and sample size of 50 μL, the regression of the peak area ratios of benzene and toluene to IS on the concentrations of analytes fitted a linear relationship well at the concentration levels ranging from 3.2 g/L to 16.0 g/L. Standard additions of benzene and toluene to blank different matrix solutions 1ead to recoveries of 100.1%–109.5% with a relative standard deviation (RSD) of 0.3%–8.1%. The method presented here stands out as simple and easily applicable, which provides a way for the determination of toxic volatile adjuvant in liquid pesticide formulations. PMID:23607048
Study of the Vapor Phase Over Fusarium Fungi Cultured on Various Substrates.
Savelieva, Elena I; Gustyleva, Liudmila K; Kessenikh, Elizaveta D; Khlebnikova, Natalya S; Leffingwell, John; Gavrilova, Olga P; Gagkaeva, Tatiana Yu
2016-07-01
The compositions of volatile organic compounds (VOCs) emitted by Fusarium fungi (F. langsethiae, F. sibiricum, F. poae, and F. sporotrichioides) grown on two nutritive substrates: potato sucrose agar (PSA) and autoclaved wheat kernels (WK) were investigated. The culturing of fungi and study of their VOC emissions were performed in chromatographic vials at room temperature (23 - 24 °C) and the VOCs were sampled by a solid-phase microextraction on a 85 μm carboxen/polydimethylsiloxane fiber. GC/MS was performed using a 60-m HP-5 capillary column. Components of the VOC mixture were identified by electron impact mass spectra and chromatographic retention indices (RIs). The most abundant components of the VOC mixture emitted by Fusarium fungi are EtOH, AcOH, (i) BuOH, 3-methylbutan-1-ol, 2-methylbutan-1-ol, ethyl 3-methylbutanoate, terpenes with M 136, sesquiterpenes with M 204 (a total of about 25), and trichodiene. It was found that the strains grown on PSA emit a wider spectrum and larger amount of VOCs compared with those grown on wheat kernels. F. langsethiae strain is the most active VOC producer on both substrates. The use of SPME and GC/MS also offers the potential for differentiation of fungal species and strains. © 2016 Wiley-VHCA AG, Zürich.
Kapsimali, D C; Zachariadis, G A
2009-10-01
Two solid phase microextraction modes were investigated and compared for their performance on the determination of selenites in various biological liquids like human urine and saliva and various types of milk. Using sodium tetraethylborate (NaBEt(4)) as ethylating reagent, selenites are converted in situ to volatile diethylselenides (DESe) in aqueous medium. The derivative is collected in situ by solid phase microextraction (SPME) using a silica fiber coated with poly(dimethylsiloxane) (PDMS) either from the headspace (HS-SPME) or directly from the liquid phase (LP-SPME) and finally determined by capillary GC/MS. Under optimum conditions of SPME, the GC separation was also optimized. Between the two examined microextraction techniques, direct immersion of the PDMS fiber in the liquid phase was proved less satisfactory. In contrast, the headspace procedure appears to be more efficient. The quantification of selenites was achieved in SIM mode with good analytical performance. A non-fat milk powder certified reference material was analyzed to evaluate the accuracy of the method. The overall precision of the method was ranged between 6.2% and 9.7%. Detection limits achieved were 0.05microgL(-1) for human urine, 0.08microgL(-1) for saliva and 0.03-0.06microgL(-1) in various milk matrices.
Awad, Tamer; Maher, Hadir M; DeRuiter, Jack; Clark, C Randall
2011-05-01
The mass spectra of the controlled substance 3,4-MDMA and its regioisomer 2,3-MDMA are characterized by an imine fragment base peak at m/z 58 and additional fragments at m/z 135/136 for the methylenedioxybenzyl cation and radical cation, respectively. Three positional ring methoxy isomers of N-methyl-2-(methoxyphenyl)-3-butanamine (MPBA) have an isobaric relationship to 2,3- and 3,4-MDMA. All five compounds have the same molecular weight and produce similar EI mass spectra. This lack of mass spectral specificity for the isomers in addition to the possibility of chromatographic co-elution could result in misidentification. The lack of reference materials for the potential imposter molecules constitutes a significant analytical challenge. Perfluoroacylation of the amine group reduced the nitrogen basicity and provided individual fragmentation pathways for discrimination among these compounds based on unique fragment ions and the relative abundance of common ions. Studies using gas chromatography with infrared detection provided additional structure-IR spectra relationships. The underivatized amines and the perfluoroacylated derivatives (PFPA and HFBA) were resolved by capillary gas chromatography on a 100% dimethylpolysiloxane stationary phase. The perfluoroacylated derivatives showed better resolution on a cyclodextrin modified stationary phase.
Boardman, Anna; McQuaide, Sarah C.; Zhu, Cuiru; Whitmore, Colin; Lidstrom, Mary E.; Dovichi, Norman J.
2009-01-01
We report a system that allows the simultaneous aspiration of one or more cells into each of five capillaries for electrophoresis analysis. A glass wafer was etched to create an array of 1 nL wells. The glass was treated with poly(2-hydroxyethyl methacrylate) to control cell adherence. A suspension of formalin-fixed cells was placed on the surface, and cells were allowed to settle. The concentration of cells and the settling time were chosen so that there was, on average, one cell per well. Next, an array of five capillaries was placed so that the tip of each capillary was in contact with a single well. A pulse of vacuum was applied to the distal end of the capillaries to aspirate the content of each well into a capillary. Next, the tips of the capillaries were placed in running buffer and potential was applied. The cells lysed upon contact with the running buffer, and fluorescent components were detected at the distal end of the capillaries by laser-induced fluorescence. The electrophoretic separation efficiency was outstanding, generating over 750,000 theoretical plates (1,800,000 plates/meter). In this example, AtT-20 cells were used that had been treated with TMR-GM1. The cells were allowed to metabolize this substrate into a series of products before the cells were fixed. The number of cells found in each well was estimated visually under the microscope and was described by a Poisson distribution with mean of 0.95 cells/well. This system provides an approach to high-throughput chemical cytometry. PMID:18717573
Martin Fabritius, Marie; Broillet, Alain; König, Stefan; Weinmann, Wolfgang
2018-06-04
Adsorption of volatiles in gaseous phase to activated charcoal strip (ACS) is one possibility for the extraction and concentration of ignitable liquid residues (ILRs) from fire debris in arson investigations. Besides liquid extraction using carbon dioxide or hexane, automated thermo-desorption can be used to transfer adsorbed residues to direct analysis by gas chromatography-mass spectrometry (GC-MS). We present a fire debris analysis work-flow with headspace adsorption of volatiles onto ACS and subsequent automated thermo-desorption (ATD) GC-MS analysis. Only a small portion of the ACS is inserted in the ATD tube for thermal desorption coupled to GC-MS, allowing for subsequent confirmation analysis with another portion of the same ACS. This approach is a promising alternative to the routinely used ACS method with solvent extraction of retained volatiles, and the application to fire debris analysis is demonstrated. Copyright © 2018 Elsevier B.V. All rights reserved.
Sobrado, Laura Alonso; Freije-Carrelo, Laura; Moldovan, Mariella; Encinar, Jorge Ruiz; Alonso, J Ignacio García
2016-07-29
GC-FID has been effectively used as a universal quantification technique for volatile organic compounds for a long time. In most cases, the use of the ECN allows for quantification by GC-FID without external calibration using only the response of a single internal standard. In this paper we compare the performance characteristics of GC-FID with those of post-column (13)C Isotope Dilution GC-Combustion-MS for the absolute quantification of organic compounds without the need for individual standards. For this comparison we have selected the quantification of FAMEs in biodiesel. The selection of the right internal standard was critical for GC-FID even when ECN were considered. On the other hand, the nature of the internal standard was not relevant when GC-Combustion-MS was employed. The proposed method was validated with the analysis of the certified reference material SRM 2772 and comparative data was obtained on real biodiesel samples. The analysis of the SRM 2772 biodiesel provided recoveries in the range 100.6-103.5% and 96.4-103.6% for GC-combustion-MS and GC-FID, respectively. The detection limit for GC-combustion-MS was found to be 4.2ng compound/g of injected sample. In conclusion, the quantitative performance of GC-Combustion-MS compared satisfactorily with that of GC-FID constituting a viable alternative for the quantification of organic compounds without the need for individual standards. Copyright © 2016 Elsevier B.V. All rights reserved.
Analysis of pilocarpine and its trans epimer, isopilocarpine, by capillary electrophoresis.
Baeyens, W; Weiss, G; Van Der Weken, G; Van Den Bossche, W
1993-05-28
Capillary zone electrophoresis was used for the separation of pilocarpine from its epimer, isopilocarpine, using coated fused-silica capillaries of 20 cm x 25 microm I.D., 8 kV running voltage, migration buffer of 0.1 M sodium dihydrogenphosphate pH 8, detection at 217 nm and injection by electromigration. Injections of aqueous, acid and basic solutions were compared. Linearity of the signal for pilocarpine hydrochloride up to 200 microg ml(-1) in 0.05 M hydrochloric acid was obtained, using naphazoline nitrate as internal standard. Optimization of migration buffer pH using coated silica capillaries of 50 cm x 50 microm I.D. showed that at pH 6.9 pilocarpine can be separated from ++isopilocarpine. Inclusion of beta-cyclodextrin in the buffer allows full baseline separation of both epimers. The method was applied to the analysis of a commercial ophthalmic pilocarpine solution.
Klepárník, Karel
2015-01-01
This review focuses on the latest development of microseparation electromigration methods in capillaries and microfluidic devices with MS detection and identification. A wide selection of 183 relevant articles covers the literature published from June 2012 till May 2014 as a continuation of the review article on the same topic by Kleparnik [Electrophoresis 2013, 34, 70-86]. Special attention is paid to the new improvements in the theory of instrumentation and methodology of MS interfacing with capillary versions of zone electrophoresis, ITP, and IEF. Ionization methods in MS include ESI, MALDI, and ICP. Although the main attention is paid to the development of instrumentation and methodology, representative examples illustrate also applications in the proteomics, glycomics, metabolomics, biomarker research, forensics, pharmacology, food analysis, and single-cell analysis. The combinations of MS with capillary versions of electrochromatography and micellar electrokinetic chromatography are not included. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
GC/HRSIR as a Complementary Technique to GC/ECNIMS
Gas chromatography/electron capture negative ion mass spectrometry (GC/ECNIMS) is a highly selective and sensitive technique for the analysis of appropriate analytes in complex matrices. Its major drawback is often the lack of fragmentation indicative of structure that can be use...
Yang, Heejung; Lee, Dong Young; Jeon, Minji; Suh, Youngbae; Sung, Sang Hyun
2014-05-01
Five active compounds, chlorogenic acid, 3,5-di-O-caffeoylquinic acid, 4,5-di-O-caffeoylquinic acid, jaceosidin, and eupatilin, in Artemisia princeps (Compositae) were simultaneously determined by ultra-performance liquid chromatography connected to diode array detector. The morphological resemblance between A. princeps and A. capillaris makes it difficult to properly identify species properly. It occasionally leads to misuse or misapplication in Korean traditional medicine. In the study, the discrimination between A. princeps and A. capillaris was optimally performed by the developed validation method, which resulted in definitely a difference between two species. Also, it was developed the most reliable markers contributing to the discrimination of two species by the multivariate analysis methods, such as a principal component analysis and a partial least squares discrimination analysis.
Kanda, Mitsuro; Tanaka, Chie; Kobayashi, Daisuke; Tanaka, Haruyoshi; Shimizu, Dai; Shibata, Masahiro; Takami, Hideki; Hayashi, Masamichi; Iwata, Naoki; Niwa, Yukiko; Yamada, Suguru; Fujii, Tsutomu; Nakayama, Goro; Fujiwara, Michitaka; Kodera, Yasuhiro
2016-11-15
Prediction of tumor recurrence after curative resection is critical for determining the prognosis of patients with gastric cancer (GC). The initiation and progression of GC are associated with inappropriate immune responses caused by chronic inflammation of the gastric mucosa. To identify immunoregulatory molecules involved in GC progression, GC cell lines and 200 pairs of tumor and normal tissues from patients with GC were analyzed for gene expression, amplification and methylation as well as function of a differentially expressed gene. The transcriptome analysis revealed that marginal zone B and B1 cell specific protein (MZB1) was expressed at significantly decreased levels in primary GC tissues when compared with the corresponding normal gastric mucosa. PCR array analysis exploring genes expressed cooperatively with MZB1 revealed that differential expression of MZB1 mRNA in GC cell lines correlated positively with the levels of the mRNAs encoding estrogen receptor 1 and desumoylating isopeptidase 1. Hypermethylation of the MZB1 promoter was frequent in cell lines with decreased levels of MZB1 mRNA. siRNA-mediated knockdown of MZB1 significantly increased proliferation, invasion and migration of GC cell lines. Low MZB1 expression was an independent prognostic factor for recurrence after curative gastrectomy and was associated significantly with increased hematogenous recurrence. MZB1 acts as a suppressor of GC. Low MZB1 expression in the primary GC tissue is predictive of recurrence after curative resection. © 2016 UICC.
Compound Capillary Flows in Complex Containers: Drop Tower Test Results
NASA Astrophysics Data System (ADS)
Bolleddula, Daniel A.; Chen, Yongkang; Semerjian, Ben; Tavan, Noël; Weislogel, Mark M.
2010-10-01
Drop towers continue to provide unique capabilities to investigate capillary flow phenomena relevant to terrestrial and space-based capillary fluidics applications. In this study certain `capillary rise' flows and the value of drop tower experimental investigations are briefly reviewed. A new analytic solution for flows along planar interior edges is presented. A selection of test cell geometries are then discussed where compound capillary flows occur spontaneously and simultaneously over local and global length scales. Sample experimental results are provided. Tertiary experiments on a family of asymmetric geometries that isolate the global component of such flows are then presented along with a qualitative analysis that may be used to either avoid or exploit such flows. The latter may also serve as a design tool with which to assess the impact of inadvertent container asymmetry.
Miao, Qing; Kong, Weijun; Zhao, Xiangsheng; Yang, Shihai; Yang, Meihua
2015-01-01
Analytical methods for quantitative analysis and chemical fingerprinting of volatile oils from Alpinia oxyphylla were established. The volatile oils were prepared by hydrodistillation, and the yields were between 0.82% and 1.33%. The developed gas chromatography-flame ionization detection (GC-FID) method showed good specificity, linearity, reproducibility, stability and recovery, and could be used satisfactorily for quantitative analysis. The results showed that the volatile oils contained 2.31-77.30 μL/mL p-cymene and 12.38-99.34 mg/mL nootkatone. A GC-FID fingerprinting method was established, and the profiles were analyzed using chemometrics. GC-MS was used to identify the principal compounds in the GC-FID profiles. The profiles of almost all the samples were consistent and stable. The harvesting time and source were major factors that affected the profile, while the volatile oil yield and the nootkatone content had minor secondary effects. Copyright © 2014 Elsevier B.V. All rights reserved.
Risk factors associated with gastric cancer in Mexico: education, breakfast and chili.
Trujillo Rivera, Alejandro; Sampieri, Clara Luz; Morales Romero, Jaime; Montero, Hilda; Acosta Mesa, Héctor Gabriel; Cruz Ramírez, Nicandro; Novoa Del Toro, Elva María; León Córdoba, Kenneth
2018-06-01
the aim of the study was to use a validated questionnaire to identify factors associated with the development of gastric cancer (GC) in the Mexican population. the study included cases and controls that were paired by sex and ± 10 years of age at diagnosis. In relation to cases, 46 patients with a confirmed histopathological diagnosis of adenocarcinoma-type GC, as reported in the hospital records, were selected, and 46 blood bank donors from the same hospital were included as controls. The previously validated Questionnaire to Find Factors Associated with Gastric Cancer (QUFA-GC©) was used to collect data. Odds ratio (OR) and 95% confidence interval (IC) were estimated via univariate analysis (paired OR). Multivariate analysis was performed by logistic regression. A decision tree was constructed using the J48 algorithm. an association was found by univariate analysis between GC risk and a lack of formal education, having smoked for ≥ 10 years, eating rapidly, consuming very hot food and drinks, a non-suitable breakfast within two hours of waking, pickled food and capsaicin. In contrast, a protective association against GC was found with taking recreational exercise and consuming fresh fruit and vegetables. No association was found between the development of GC and having an income that reflected poverty, using a refrigerator, perception of the omission of breakfast and time period of alcoholism. In the final multivariate analysis model, having no formal education (OR = 17.47, 95% CI = 5.17-76.69), consuming a non-suitable breakfast within two hours of waking (OR = 8.99, 95% CI = 2.85-35.50) and the consumption of capsaicin ˃ 29.9 mg capsaicin per day (OR = 3.77, 95% CI = 1.21-13.11) were factors associated with GC. an association was found by multivariate analysis between the presence of GC and education, type of breakfast and the consumption of capsaicin. These variables are susceptible to intervention and can be identified via the QUFA-GC ©.
Polom, Karol; Marrelli, Daniele; Roviello, Giandomenico; Pascale, Valeria; Voglino, Costantino; Rho, Henry; Marini, Mario; Macchiarelli, Raffaele; Roviello, Franco
2017-03-01
Microsatellite instability (MSI) in gastric cancer (GC) is associated with older age. We present the clinicopathological results of younger and older patients with MSI GC. We analyzed 472 patients with GC. MSI analysis was done on fresh frozen tissue using five quasimonomorphic mononucleotide repeats: NR-21, NR-24, NR-27, BAT-25, and BAR-26. Clinical and pathological analysis was performed for different age groups. We observed better survival in elderly MSI GC patients compared to younger patients. The percentage of MSI GC increases gradually with increasing age, accounting for 48% of patients over the age of 85 years. A difference in survival was seen between MSI and MSS groups of patients older than 65 years, while no statistical difference was seen for younger groups. Multivariate analysis revealed that MSI status has a significant prognostic factor in patients aged over 70 years (MSS vs. MSI; HR 1.82, P = 0.013). MSI is an important prognostic factor above all in elderly GC patients. It is associated with favorable prognosis and may help in planning different approaches to treatment in this subgroup. J. Surg. Oncol. 2017;115:344-350. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Duffy, Ciarán F; MacCraith, Brian; Diamond, Dermot; O'Kennedy, Richard; Arriaga, Edgar A
2006-08-01
The analysis of mitochondria by capillary electrophoresis usually takes longer than 20 min per replicate which may compromise the quality of the mitochondria due to degradation. In addition, low sample consumption may be beneficial in the analysis of rare or difficult samples. In this report, we demonstrate the ability to analyze individual mitochondrial events in picoliter-volume samples (approximately 80 pL) taken from a bovine liver preparation using microchip capillary electrophoresis with laser-induced fluorescence detection (micro-chip CE-LIF). Using a commercial "double-T" glass microchip, the sample was electrokinetically loaded in the "double-T" intersection and then subjected to electrophoretic separation along the main separation channel. In order to decrease interactions of mitochondria with channel walls during the analysis, poly(vinyl alcohol) was used as a dynamic coating. This procedure eliminates the need for complicated covalent surface modifications within the channels that were previously used in capillary electrophoresis methods. For analysis, mitochondria, isolated from bovine liver tissue, were selectively labelled using 10-nonyl acridine orange (NAO). The results consist of electropherograms where each mitochondrial event is a narrow spike (240 +/- 44 ms). While the spike intensity is representative of its NAO content, its migration time is used to calculate and describe its electrophoretic mobility, which is a property still largely unexplored for intracellular organelles. The five-fold decrease in separation time (4 min for microchip versus 20 min for capillary electrophoresis) makes microchip electrophoretic separations of organelles a faster, sensitive, low-sample volume alternative for the characterization of individual organelle properties and for investigations of subcellular heterogeneity.
Kong, Pengfei; Wu, Ruiyan; Liu, Xuechao; Liu, Jianjun; Chen, Shangxiang; Ye, Minting; Yang, Chenlu; Song, Ze; He, Wenzhuo; Yin, Chenxi; Yang, Qiong; Jiang, Chang; Liao, Fangxin; Peng, Roujun; Zhou, Zhiwei; Xu, Dazhi; Xia, Liangping
2016-01-01
Gastric cancer has high incidence and fatality rates, making chemoprevention agents necessary. There is an ongoing debate about aspirin/nonsteroidal anti-inflammatory drugs (NSAIDs) use can significant reduce the risk of GC. We conducted a meta-analysis of existing studies evaluating the association of anti-inflammatory drug and GC. We performed a systematic literature search of PubMed, Web of Science, Embase, OVID, Cochrane Library and Clincialtrials.gov up to August 31, 2015. Either a fixed-effects or a random-effects model using was based on the result of homogeneity analysis. Subgroup, sensitivity, meta-regression, and publication bias analyses were evaluated. Forty-seven studies were finally included in this meta-analysis. The overall GC risk reduction benefit associated with anti-inflammatory drug use represented an RR of 0.78 (95% CI 0.71 to 0.85) and an adjusted RR of 0.74 (95% CI 0.71 to 0.77). Besides, the prevention benefit of aspirin/NSAIDs ingestion appeared to be confined to those patients with regiment of short or middle-term (≤5 years), high-frequency (>30 times per month) and low dose (<200 mg per day). Further, our data also suggest that COX-2 inhibitors use is a more effective approach in GC prevention (RR, 0.45; 95% CI, 0.29-0.70). In this meta-analysis, our finding support short or middle-term (≤5 years), high-frequency (>30 times per month) and low dose (<200 mg per day) aspirin/NSAIDs intake is a well method for GC prevention and also confirm the inverse association between aspirin/NSAIDs use and GC risk. Additionally, selective COX-2 inhibitors use probably a more effective approach to reduce GC risk. PMID:27994661
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Sooyoung; Yoon, Suk-Jin, E-mail: sjyoon0691@yonsei.ac.kr
Spectroscopy on the globular cluster (GC) system of NGC 5128 revealed bimodality in absorption-line index distributions of its old GCs. GC division is a widely observed and studied phenomenon whose interpretation has depicted host galaxy formation and evolution such that it harbors two distinct metallicity groups. Such a conventional view of GC bimodality has mainly been based on photometry. The recent GC photometric data, however, presented an alternative perspective in which the nonlinear metallicity-to-color transformation is responsible for color bimodality of GC systems. Here we apply the same line of analysis to the spectral indices and examine the absorption-line indexmore » versus metallicity relations for the NGC 5128 GC system. NGC 5128 GCs display nonlinearity in the metallicity-index planes, most prominently for the Balmer lines and by a non-negligible degree for the metallicity-sensitive magnesium line. We demonstrate that the observed spectroscopic division of NGC 5128 GCs can be caused by the nonlinear nature of the metallicity-to-index conversions and thus one does not need to resort to two separate GC subgroups. Our analysis incorporating this nonlinearity provides a new perspective on the structure of NGC 5128's GC system, and a further piece to the global picture of the formation of GC systems and their host galaxies.« less
Ai, Guomin; Sun, Tong; Dong, Xiuzhu
2014-08-15
Methanol, ethanol, and acetic acid are not easily extracted from aqueous samples and are susceptible to isotope fractionation in gas chromatography/isotope ratio mass spectrometry (GC/IRMS) analysis. Developing a direct dilution GC/IRMS method for aqueous samples, by adjusting the sample concentrations in common solvents to be similar to each other and using a fixed GC split ratio, is very convenient and important because any linearity effects caused by amount-dependent isotope fractionation can be avoided. The suitability of acetonitrile and acetone solvents for the GC/IRMS analysis of pure methanol, ethanol and acetic acid, and commercial liquor and vinegar samples was evaluated using n-hexane and water as control solvents. All the solvents including water were separated from the analyte on a HP-INNOWAX column and were diverted away from the combustion interface. The influence of liquor matrix on the ethanol GC/IRMS analyses was evaluated by adding pure ethanol to liquor samples. Acetonitrile and acetone gave similar δ(13) C values for pure ethanol and pure acetic acid to those obtained in water and n-hexane, and also gave similar δ(13) C values of ethanol in liquor and acetic acid in white vinegar to that obtained in water. For methanol analysis, acetonitrile and refined acetone gave similar δ(13) C values to that obtained in water, but n-hexane was not a suitable solvent. In addition, isotopic fractionation caused by solvent and solute interactions was observed. We recommend using acetonitrile for the GC/IRMS analysis of aqueous alcoholic samples, and acetone for the analysis of aqueous acetic acid samples. This direct dilution method can provide high accurate and precise GC/IRMS analysis of the relative changes in δ(13) C values of methanol, ethanol, and acetic acid. Copyright © 2014 John Wiley & Sons, Ltd.
Structure of Particle Networks in Capillary Suspensions with Wetting and Nonwetting Fluids
2016-01-01
The mechanical properties of a suspension can be dramatically altered by adding a small amount of a secondary fluid that is immiscible with the bulk phase. The substantial changes in the strength of these capillary suspensions arise due to the capillary force inducing a percolating particle network. Spatial information on the structure of the particle networks is obtained using confocal microscopy. It is possible, for the first time, to visualize the different types of percolating structures of capillary suspensions in situ. These capillary networks are unique from other types of particulate networks due to the nature of the capillary attraction. We investigate the influence of the three-phase contact angle on the structure of an oil-based capillary suspension with silica microspheres. Contact angles smaller than 90° lead to pendular networks of particles connected with single capillary bridges or clusters comparable to the funicular state in wet granular matter, whereas a different clustered structure, the capillary state, forms for angles larger than 90°. Particle pair distribution functions are obtained by image analysis, which demonstrate differences in the network microstructures. When porous particles are used, the pendular conformation also appears for apparent contact angles larger than 90°. The complex shear modulus can be correlated to these microstructural changes. When the percolating structure is formed, the complex shear modulus increases by nearly three decades. Pendular bridges lead to stronger networks than the capillary state network conformations, but the capillary state clusters are nevertheless much stronger than pure suspensions without the added liquid. PMID:26807651
Metabolomics and Trace Element Analysis of Camel Tear by GC-MS and ICP-MS.
Ahamad, Syed Rizwan; Raish, Mohammad; Yaqoob, Syed Hilal; Khan, Altaf; Shakeel, Faiyaz
2017-06-01
Camel tear metabolomics and elemental analysis are useful in getting the information regarding the components responsible for maintaining the protective system that allows living in the desert and dry regions. The aim of this study was to correlate that the camel tears can be used as artificial tears for the evaluation of dryness in the eye. Eye biomarkers of camel tears were analyzed by gas chromatography-mass spectroscopy (GC-MS) and inductively coupled plasma mass spectroscopy (ICP-MS). The major compounds detected in camel tears by GC-MS were alanine, valine, leucine, norvaline, glycine, cadaverine, urea, ribitol, sugars, and higher fatty acids like octadecanoic acid and hexadecanoic acid. GC-MS analysis of camel tears also finds several products of metabolites and its associated metabolic participants. ICP-MS analysis showed the presence of different concentration of elemental composition in the camel tears.
Greenhouse Gas Analysis by GC/MS
NASA Astrophysics Data System (ADS)
Bock, E. M.; Easton, Z. M.; Macek, P.
2015-12-01
Current methods to analyze greenhouse gases rely on designated complex, multiple-column, multiple-detector gas chromatographs. A novel method was developed in partnership with Shimadzu for simultaneous quantification of carbon dioxide (CO2), methane (CH4), and nitrous oxide (N2O) in environmental gas samples. Gas bulbs were used to make custom standard mixtures by injecting small volumes of pure analyte into the nitrogen-filled bulb. Resulting calibration curves were validated using a certified gas standard. The use of GC/MS systems to perform this analysis has the potential to move the analysis of greenhouse gasses from expensive, custom GC systems to standard single-quadrupole GC/MS systems that are available in most laboratories, which wide variety of applications beyond greenhouse gas analysis. Additionally, use of mass spectrometry can provide confirmation of identity of target analytes, and will assist in the identification of unknown peaks should they be present in the chromatogram.
Lin, Che-Hsin; Wang, Yao-Nan; Fu, Lung-Ming
2012-01-01
An integrated microfluidic chip is proposed for rapid DNA digestion and time-resolved capillary electrophoresis (CE) analysis. The chip comprises two gel-filled chambers for DNA enrichment and purification, respectively, a T-form micromixer for DNA/restriction enzyme mixing, a serpentine channel for DNA digestion reaction, and a CE channel for on-line capillary electrophoresis analysis. The DNA and restriction enzyme are mixed electroomostically using a pinched-switching DC field. The experimental and numerical results show that a mixing performance of 97% is achieved within a distance of 1 mm from the T-junction when a driving voltage of 90 V/cm and a switching frequency of 4 Hz are applied. Successive mixing digestion and capillary electrophoresis operation clearly present the changes on digesting φx-174 DNA in different CE runs. The time-resolved electropherograms show that the proposed device enables a φx-174 DNA sample comprising 11 fragments to be concentrated and analyzed within 24 min. Overall, the results presented in this study show that the proposed microfluidic chip provides a rapid and effective tool for DNA digestion and CE analysis applications. PMID:22662085
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gámez-Mendoza, Liliana; Resto, Oscar; Martínez-Iñesta, María
2015-09-20
Kapton HN-type polyimide capillaries are commonly used as sample holders for transmission X-ray experiments at temperatures below 673 K because of their thermal stability, high X-ray transmittance and low cost. Using high-angle annular dark field scanning high-resolution transmission electron microscopy and thermogravimetric analysis, this work shows that using polyimide capillaries leads to the overgrowth of supported Pt nanoparticles during reduction at temperatures below the glass transition temperature (T g= 658 K) owing to an outgassing of water from the polyimide. Quartz capillaries were also studied and this overgrowth was not observed.
Peripapillary vessel density changes in Leber's Hereditary Optic Neuropathy: a new biomarker.
Balducci, Nicole; Cascavilla, Maria Lucia; Ciardella, Antonio; La Morgia, Chiara; Triolo, Giacinto; Parisi, Vincenzo; Bandello, Francesco; Sadun, Alfredo A; Carelli, Valerio; Barboni, Piero
2018-05-22
The contribution of the microvascular supply to the pathogenesis of Leber's Hereditary Optic Neuropathy (LHON) is poorly understood. We aimed at measuring the peripapillary capillary vessel density (VD) using optical coherence tomography angiography (OCT-A) at different stages of LHON. Prospective, cross-sectional, multicenter, observational study. Twenty-two LHON patients divided in 4 groups: unaffected mutation carriers (LHON-u); early subacute stage (LHON-e); late subacute stage (LHON-l); chronic stage (LHON-ch). OCT-A scans centered on the optic disc were obtained by spectral domain OCT system. VD, retinal nerve fiber layer (RNFL) and ganglion cell inner plexiform layer (GC-IPL) thickness were compared between groups. Significant VD changes were detected in every sector (p<0.0001). In LHON-e, the VD was reduced in the temporal sector compared with LHON-u and in the temporal and inferotemporal sectors compared with controls. In LHON-l, VD was reduced in whole, temporal, superotemporal and inferotemporal sectors compared with LHON-u and controls. In LHON-ch, the VD was reduced in all sectors compared to the other groups. An asynchronous pattern emerged in the temporal sector with VD changes occurring earlier than RNFL thickness changes and together with GC-IPL thinning. Significant peripapillary miscrovascular changes were detected over the different stages of LHON. Studying the vascular network separately from fibers revealed that microvascular changes in the temporal sector preceded the changes of RNFL and mirrored the GC-IPL changes. Measurements of the peripapillary vascular network may become a useful biomarker to monitor the disease process, evaluate therapeutic efficacy and elucidate pathophysiology. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Luna, V; Lorenzo, E; Reinoso, H; Tordable, M C; Abdala, G; Pharis, R P; Bottini, R
1990-05-01
Flower buds of peach (Prunus persica L.) trees, cv Novedad de Cordoba (Argentina), were collected near the end of the dormant period and immediately before anthesis. After removal of scale leaves, morphological observations of representative buds, made on transverse and longitudinal microtome sections, showed that all verticils making up the flower are present in an undifferentiated form during the dormant period (June). Flower buds collected at the end of dormant period (August) showed additional growth and differentiation, at which time formation of two ovules was beginning in the unicarpelar gynoecium. Dehiscence of anthers had not yet occurred 10 days before full bloom, and the ovules were still developing. Free endogenous gibberellin (GA)-like substances were quantified by bioassay (Tan-ginbozu dwarf rice microdrop) after SiO(2) partition column chromatography, reversed phase C18-high performance liquid chromatography, and finally Nucleosil [N(CH(3))(2)]high performance liquid chromatography. Bioactive fractions were then subjected to capillary gas chromatography-mass spectrometry-selected ion monitoring (GC-MS-SIM). Gibberellins A(1), A(3), and A(8) were tentatively identified in peach flower buds using GC-SIM and Kovat's retention indices, and relative amounts approximated by GC-SIM (2:8:6 for GA(1), GA(3), and GA(8), respectively). The highest concentration (330 nanograms per gram dry weight) of free GA(1)/GA(3) was found in dormant buds (June) and diminished thereafter. The concentration free of GA(1)/GA(3) did not increase immediately prior to bud break. However, high GA(1)/GA(3) concentrations occurred during stages where rate of growth and cellular differentiation of (mainly fertile) verticils can be influenced.
Single Pulse Searches for Pulsars in the Galactic Center
NASA Astrophysics Data System (ADS)
Cushey, Daniel Joseph; Majid, Walid A.; Prince, Thomas Allen
2017-01-01
The discovery of the magnetar J1745-2900 within 3'' of Sgr A* by Mori et al. (2013) has renewed strong interest in Galactic Center (GC) pulsars and motivated expanded searches for their pulses due to their extensive applications to gravitational and plasma physics. There are currently 5 known pulsars within 15' of the Sgr A*; however, gamma ray excesses from the GC suggest a source population of 102-103 millisecond pulsars within the same region. Although this discrepancy is readily explained by the hyper-strong scattering environment of the GC which obscures pulses, the discovery of J1745-2900 challenges this attribution and further observations and analysis are needed to reconcile the observed GC pulsar population with theory. We present a pipeline developed to search for these "missing" GC pulsars using a single pulse search algorithm. Observations of the GC using the Deep Space Network 70m antenna were taken in the high frequency regime in order to minimize scattering, and search parameters were calibrated using pulses from RRAT J1819-1458. Any detected pulses that are distinct from those of J1745-2900 warrant extensive follow-up observations and analysis, and confirmed new members of the elusive GC pulsar population would be incredibly valuable as probes of the GC's magnetic and potential fields.
Joint graph cut and relative fuzzy connectedness image segmentation algorithm.
Ciesielski, Krzysztof Chris; Miranda, Paulo A V; Falcão, Alexandre X; Udupa, Jayaram K
2013-12-01
We introduce an image segmentation algorithm, called GC(sum)(max), which combines, in novel manner, the strengths of two popular algorithms: Relative Fuzzy Connectedness (RFC) and (standard) Graph Cut (GC). We show, both theoretically and experimentally, that GC(sum)(max) preserves robustness of RFC with respect to the seed choice (thus, avoiding "shrinking problem" of GC), while keeping GC's stronger control over the problem of "leaking though poorly defined boundary segments." The analysis of GC(sum)(max) is greatly facilitated by our recent theoretical results that RFC can be described within the framework of Generalized GC (GGC) segmentation algorithms. In our implementation of GC(sum)(max) we use, as a subroutine, a version of RFC algorithm (based on Image Forest Transform) that runs (provably) in linear time with respect to the image size. This results in GC(sum)(max) running in a time close to linear. Experimental comparison of GC(sum)(max) to GC, an iterative version of RFC (IRFC), and power watershed (PW), based on a variety medical and non-medical images, indicates superior accuracy performance of GC(sum)(max) over these other methods, resulting in a rank ordering of GC(sum)(max)>PW∼IRFC>GC. Copyright © 2013 Elsevier B.V. All rights reserved.
IB-LBM simulation of the haemocyte dynamics in a stenotic capillary.
Yuan-Qing, Xu; Xiao-Ying, Tang; Fang-Bao, Tian; Yu-Hua, Peng; Yong, Xu; Yan-Jun, Zeng
2014-01-01
To study the behaviour of a haemocyte when crossing a stenotic capillary, the immersed boundary-lattice Boltzmann method was used to establish a quantitative analysis model. The haemocyte was assumed to be spherical and to have an elastic cell membrane, which can be driven by blood flow to adopt a highly deformable character. In the stenotic capillary, the spherical blood cell was stressed both by the flow and the wall dimension, and the cell shape was forced to be stretched to cross the stenosis. Our simulation investigated the haemocyte crossing process in detail. The velocity and pressure were anatomised to obtain information on how blood flows through a capillary and to estimate the degree of cell damage caused by excessive pressure. Quantitative velocity analysis results demonstrated that a large haemocyte crossing a small stenosis would have a noticeable effect on blood flow, while quantitative pressure distribution analysis results indicated that the crossing process would produce a special pressure distribution in the cell interior and to some extent a sudden change between the cell interior and the surrounding plasma.
Sanderson, Patience; Stickney, Morgan; Leach, Franklin E; Xia, Qiangwei; Yu, Yanlei; Zhang, Fuming; Linhardt, Robert J; Amster, I Jonathan
2018-04-13
Reverse polarity capillary zone electrophoresis coupled to negative ion mode mass spectrometry (CZE-MS) is shown to be an effective and sensitive tool for the analysis of glycosaminoglycan mixtures. Covalent modification of the inner wall of the separation capillary with neutral or cationic reagents produces a stable and durable surface that provides reproducible separations. By combining CZE-MS with a cation-coated capillary and a sheath flow interface, a rapid and reliable method has been developed for the analysis of sulfated oligosaccharides from dp4 to dp12. Several different mixtures have been separated and detected by mass spectrometry. The mixtures were selected to test the capability of this approach to resolve subtle differences in structure, such as sulfation position and epimeric variation of the uronic acid. The system was applied to a complex mixture of heparin/heparan sulfate oligosaccharides varying in chain length from dp3 to dp12 and more than 80 molecular compositions were identified by accurate mass measurement. Copyright © 2018 Elsevier B.V. All rights reserved.
Park, Keunchil; Cho, Eun Kyung; Bello, Maximino; Ahn, Myung-Ju; Thongprasert, Sumitra; Song, Eun-Kee; Soldatenkova, Victoria; Depenbrock, Henrik; Puri, Tarun; Orlando, Mauro
2017-10-01
The phase 3 randomized SQUIRE study revealed significantly longer overall survival (OS) and progression-free survival (PFS) for necitumumab plus gemcitabine and cisplatin (neci+GC) than for gemcitabine and cisplatin alone (GC) in 1,093 patients with previously untreated advanced squamous non-small cell lung cancer (NSCLC). This post hoc subgroup analysis assessed the efficacy and safety of neci+GC among East Asian (EA) patients enrolled in the study. All patients received up to six 3-week cycles of gemcitabine (days 1 and 8, 1,250 mg/m²) and cisplatin (day 1, 75 mg/m²). Patients in the neci+GC arm also received necitumumab (days 1 and 8, 800 mg) until disease progression or unacceptable toxicity. Hazard ratios (HRs) and 95% confidence intervals (CIs) were estimated from stratified Cox proportional hazards models. In EA patients, there were improvements for neci+GC (n=43) versus GC (n=41) in OS (HR, 0.805; 95% CI, 0.484 to 1.341) and PFS (HR, 0.720; 95% CI, 0.439 to 1.180), consistent with the results for non-EA patients observed in the present study. The overall safety data were consistent between EA and non-EA patients. A numerically higher proportion of patients experienced serious adverse events (AEs), grade ≥ 3 AEs, and AEs with an outcome of death for neci+GC versus GC in EA patients and EA patients versus non-EA patients for neci+GC. Although limited by the small sample size and post hoc nature of the analysis, these findings are consistent with those of the overall study and suggest that neci+GC offers a survival advantage and favorable benefit/risk for EA patients with advanced squamous NSCLC.
Guo, Heying; Niu, Xiaoying; Pan, Congjie; Yi, Tao; Chen, Hongli; Chen, Xingguo
2017-06-01
Inspired by the chiral recognition ability of β-cyclodextrin and the natural adhesive properties of polydopamine under alkaline conditions, in this study, a rapid and in situ modification strategy was developed to fabricate β-cyclodextrin/polydopamine composite material coated-capillary columns for open tubular capillary electrochromatography. The results of scanning electron microscopy, FTIR spectroscopy, streaming potential, and electro-osmotic flow studies indicated that β-cyclodextrin/polydopamine was successfully fixed on the inner wall of the capillary column. This coating can be achieved within 1 h affording a greatly reduced capillary preparation time. The performance of the β-cyclodextrin/polydopamine-coated capillary was validated by the analysis of seven pairs of chiral analytes, namely epinephrine, norepinephrine, isoprenaline, terbutaline, verapamil, tryptophane, carvedilol. Good enantioseparation efficiencies were achieved for all. For three consecutive runs, the relative standard deviations for the migration times of the analytes for intraday, interday, and column-to-column repeatability were in the range of 0.41-1.74, 1.03-4.18, and 1.66-8.24%, respectively. Moreover, the separation efficiency of the β-cyclodextrin/polydopamine-coated capillary column did not decrease obviously over 90 runs. The strategy should also be feasible to introduce and immobilize other chiral selectors on the inner walls surface of capillary columns. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Harvey, Scott D; Jarman, Kristin H; Moran, James J; Sorensen, Christina M; Wright, Bob W
2012-09-15
The purpose of this study was to perform a preliminary investigation of compound-specific isotope analysis (CSIA) of diesel fuels to evaluate whether the technique could distinguish diesel samples from different sources/locations. The ability to differentiate or correlate diesel samples could be valuable for discovering fuel tax evasion schemes or for environmental forensic studies. Two urea adduction-based techniques were used to isolate the n-alkanes from the fuel. Both carbon isotope ratio (δ(13)C) and hydrogen isotope ratio (δD) values for the n-alkanes were then determined by CSIA in each sample. The samples investigated had δ(13)C values that ranged from -30.1‰ to -26.8‰, whereas δD values ranged from -83‰ to -156‰. Plots of δD versus δ(13)C with sample n-alkane points connected in order of increasing carbon number gave well-separated clusters with characteristic shapes for each sample. Principal components analysis (PCA) with δ(13)C, δD, or combined δ(13)C and δD data was applied to extract the maximum information content. PCA scores plots could clearly differentiate the samples, thereby demonstrating the potential of this approach for distinguishing (e.g., fingerprinting) fuel samples using δ(13)C and δD values. Copyright © 2012 Elsevier B.V. All rights reserved.
Garg, Prabhat; Purohit, Ajay; Tak, Vijay K; Dubey, D K
2009-11-06
N,N-Dialkylamino alcohols, N-methyldiethanolamine, N-ethyldiethanolamine and triethanolamine are the precursors of VX type nerve agents and three different nitrogen mustards respectively. Their detection and identification is of paramount importance for verification analysis of chemical weapons convention. GC-FTIR is used as complimentary technique to GC-MS analysis for identification of these analytes. One constraint of GC-FTIR, its low sensitivity, was overcome by converting the analytes to their fluorinated derivatives. Owing to high absorptivity in IR region, these derivatives facilitated their detection by GC-FTIR analysis. Derivatizing reagents having trimethylsilyl, trifluoroacyl and heptafluorobutyryl groups on imidazole moiety were screened. Derivatives formed there were analyzed by GC-FTIR quantitatively. Of these reagents studied, heptafluorobutyrylimidazole (HFBI) produced the greatest increase in sensitivity by GC-FTIR detection. 60-125 folds of sensitivity enhancement were observed for the analytes by HFBI derivatization. Absorbance due to various functional groups responsible for enhanced sensitivity were compared by determining their corresponding relative molar extinction coefficients ( [Formula: see text] ) considering uniform optical path length. The RSDs for intraday repeatability and interday reproducibility for various derivatives were 0.2-1.1% and 0.3-1.8%. Limit of detection (LOD) was achieved up to 10-15ng and applicability of the method was tested with unknown samples obtained in international proficiency tests.
Causality Analysis of fMRI Data Based on the Directed Information Theory Framework.
Wang, Zhe; Alahmadi, Ahmed; Zhu, David C; Li, Tongtong
2016-05-01
This paper aims to conduct fMRI-based causality analysis in brain connectivity by exploiting the directed information (DI) theory framework. Unlike the well-known Granger causality (GC) analysis, which relies on the linear prediction technique, the DI theory framework does not have any modeling constraints on the sequences to be evaluated and ensures estimation convergence. Moreover, it can be used to generate the GC graphs. In this paper, first, we introduce the core concepts in the DI framework. Second, we present how to conduct causality analysis using DI measures between two time series. We provide the detailed procedure on how to calculate the DI for two finite-time series. The two major steps involved here are optimal bin size selection for data digitization and probability estimation. Finally, we demonstrate the applicability of DI-based causality analysis using both the simulated data and experimental fMRI data, and compare the results with that of the GC analysis. Our analysis indicates that GC analysis is effective in detecting linear or nearly linear causal relationship, but may have difficulty in capturing nonlinear causal relationships. On the other hand, DI-based causality analysis is more effective in capturing both linear and nonlinear causal relationships. Moreover, it is observed that brain connectivity among different regions generally involves dynamic two-way information transmissions between them. Our results show that when bidirectional information flow is present, DI is more effective than GC to quantify the overall causal relationship.
Su, Chi-Ju; Srimurugan, Sankarewaran; Chen, Chinpiao; Shu, Hun-Chi
2011-01-01
Novel sol-gel titania film coated needles for solid-phase dynamic extraction (SPDE)-GC/MS analysis of desomorphine and desocodeine are described. The high thermal stability of titania film permits efficient extraction and analysis of poorly volatile opiate drugs. The influences of sol-gel reaction time, coating layer, extraction and desorption time and temperature on the SPDE needle performance were investigated. The deuterium labeled internal standard was introduced either during the extraction of analyte or directly injected to GC after the extraction process. The latter method was shown to be more sensitive for the analysis of water and urine samples containing opiate drugs. The proposed conditions provided a wide linear range (from 5-5000 ppb), and satisfactory linearity, with R(2) values from 0.9958 to 0.9999, and prominent sensitivity, LOQs (1.0-5.0 ng/g). The sol-gel titania film coated needle with SPDE-GC/MS will be a promising technique for desomorphine and desocodeine analysis in urine.
Farhadi, Ashkan; Keshavarzian, Ali; Fields, Jeremy Z; Sheikh, Maliha; Banan, Ali
2006-05-19
The most widely accepted method for the evaluation of intestinal barrier integrity is the measurement of the permeation of sugar probes following an oral test dose of sugars. The most-widely used sugar probes are sucrose, lactulose, mannitol and sucralose. Measuring these sugars using a sensitive gas chromatographic (GC) method, we noticed interference on the area of the lactulose and mannitol peaks. We tested different sugars to detect the possible makeup of these interferences and finally detected that the lactose interferes with lactulose peak and fructose interferes with mannitol peak. On further developing of our method, we were able to reasonably separate these peaks using different columns and condition for our assay. Sample preparation was rapid and simple and included adding internal standard sugars, derivitization and silylation. We used two chromatographic methods. In the first method we used Megabore column and had a run time of 34 min. This resulted in partial separation of the peaks. In the second method we used thin capillary column and was able to reasonably separate the lactose and lactulose peaks and the mannitol and fructose peaks with run time of 22 min. The sugar probes including mannitol, sucrose, lactulose, sucralose, fructose and lactose were detected precisely, without interference. The assay was linear between lactulose concentrations of 0.5 and 40 g/L (r(2)=1.000, P<0.0001) and mannitol concentrations of 0.01 and 40 g/L (r(2)=1.000). The sensitivity of this method remained high using new column and assay condition. The minimum detectable concentration calculated for both methods was 0.5 mg/L for lactulose and 1 mg/L for mannitol. This is the first report of interference of commonly used sugars with test of intestinal permeability. These sugars are found in most of fruits and dairy products and could easily interfere with the result of permeability tests. Our new GC assay of urine sugar probes permits the simultaneous quantitation of sucralose, sucrose, mannitol and lactulose, without interference with lactose and fructose. This assay is a rapid, simple, sensitive and reproducible method to accurately measure intestinal permeability.
Study of the efficiency for ion transfer through bent capillaries.
Chen, Tsung-Chi; Xu, Wei; Garimella, Sandilya; Ouyang, Zheng
2012-11-01
Discontinuous atmospheric pressure interfaces (DAPIs) with bent capillaries represent a highly simplified and flexible means for introducing ions into a vacuum manifold for mass analysis or gas phase ion reactions. In this work, a series of capillaries of different radians and curvatures were used with DAPI for studying the impact of the capillary bending on the ion transfer. The variation of transfer efficiency was systematically characterized for dry and solvated ions. The efficiency loss for dry ions was less than one order of magnitude, even with a three-turn bent capillary. The transfer of solvated ions generated by electrospray was found to be minimally impacted by the bending of the transfer capillary. For multiply protonated ions, the transfer efficiency for ions at lower charge states could be relatively well retained, presumably due to the lower reactivity associated with proton transfer reaction and the compensation in intensity by conversion of ions at higher charge states. Copyright © 2012 John Wiley & Sons, Ltd.
Van der waals forces on thin liquid films in capillary tubes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Herdt, G.C.; Swanson, L.W.
1993-10-01
A theory of the van der Waals attraction between a thin liquid films and a capillary tube is presented assuming the presence of a vapor-liquid interface. The model is based on the surface mode analysis method of van Kampen et al. Values for the van der Waals interaction energy per unit area were calculated for liquid films of pentane on a gold substrate assuming a thin liquid film. Results indicate that the effect of capillary curvature on the van der Waals interaction increases as the ratio of the liquid film thickness to the capillary radius is increased. This trend ismore » consistent with predictions based on the Hamaker theory. Deviations from results based on the Hamaker theory are easily explained in terms of retardation of the van der Waals interaction. Because the effect of capillary curvature increases in the regime where retardation effects become important, curvature effects constitute a small correction to the van der Waals forces in a capillary tube.« less
Kim, Jungkyu; Jensen, Erik C; Stockton, Amanda M; Mathies, Richard A
2013-08-20
A fully integrated multilayer microfluidic chemical analyzer for automated sample processing and labeling, as well as analysis using capillary zone electrophoresis is developed and characterized. Using lifting gate microfluidic control valve technology, a microfluidic automaton consisting of a two-dimensional microvalve cellular array is fabricated with soft lithography in a format that enables facile integration with a microfluidic capillary electrophoresis device. The programmable sample processor performs precise mixing, metering, and routing operations that can be combined to achieve automation of complex and diverse assay protocols. Sample labeling protocols for amino acid, aldehyde/ketone and carboxylic acid analysis are performed automatically followed by automated transfer and analysis by the integrated microfluidic capillary electrophoresis chip. Equivalent performance to off-chip sample processing is demonstrated for each compound class; the automated analysis resulted in a limit of detection of ~16 nM for amino acids. Our microfluidic automaton provides a fully automated, portable microfluidic analysis system capable of autonomous analysis of diverse compound classes in challenging environments.
Role of capillary electrophoresis in the fight against doping in sports.
Harrison, Christopher R
2013-08-06
At present the role of capillary electrophoresis in the detection of doping agents in athletes is, for the most part, nonexistent. More traditional techniques, namely gas and liquid chromatography with mass spectrometric detection, remain the gold standard of antidoping tests. This Feature will investigate the in-roads that capillary electrophoresis has made, the limitations that the technique suffers from, and where the technique may grow into being a key tool for antidoping analysis.
Mukozhiwa, S Y; Khamanga, S M M; Walker, R B
2017-09-01
A capillary zone electrophoresis (CZE) method for the quantitation of captopril (CPT) using UV detection was developed. Influence of electrolyte concentration and system variables on electrophoretic separation was evaluated and a central composite design (CCD) was used to optimize the method. Variables investigated were pH, molarity, applied voltage and capillary length. The influence of sodium metabisulphite on the stability of test solutions was also investigated. The use of sodium metabisulphite prevented degradation of CPT over 24 hours. A fused uncoated silica capillary of 67.5cm total and 57.5 cm effective length was used for analysis. The applied voltage and capillary length affected the migration time of CPT significantly. A 20 mM phosphate buffer adjusted to pH 7.0 was used as running buffer and an applied voltage of 23.90 kV was suitable to effect a separation. The optimized electrophoretic conditions produced sharp, well-resolved peaks for CPT and sodium metabisulphite. Linear regression analysis of the response for CPT standards revealed the method was linear (R2 = 0.9995) over the range 5-70 μg/mL. The limits of quantitation and detection were 5 and 1.5 μg/mL. A simple, rapid and reliable CZE method has been developed and successfully applied to the analysis of commercially available CPT products.
Lu, Xinqiong; Yu, Quan; Zhang, Qian; Ni, Kai; Qian, Xiang; Tang, Fei; Wang, Xiaohao
2017-08-01
A miniature ion trap mass spectrometer with capillary direct sampling and vacuum ultraviolet photoionization source was developed to conduct trace analysis of organic compounds in liquids. Self-aspiration sampling is available where the samples are drawn into the vacuum chamber through a capillary with an extremely low flow rate (less than 1 μL/min), which minimizes sample consumption in each analysis to tens of micrograms. A pulsed gas-assisted inlet was designed and optimized to promote sample transmission in the tube and facilitate the cooling of ions, thereby improving instrument sensitivity. A limit of detection of 2 ppb could be achieved for 2,4-dimethylaniline in a methanol solution. The sampling system described in the present study is specifically suitable for a miniature photoionization ion trap mass spectrometer that can perform rapid and online analysis for liquid samples. Graphical Abstract ᅟ.
NASA Astrophysics Data System (ADS)
Lu, Xinqiong; Yu, Quan; Zhang, Qian; Ni, Kai; Qian, Xiang; Tang, Fei; Wang, Xiaohao
2017-08-01
A miniature ion trap mass spectrometer with capillary direct sampling and vacuum ultraviolet photoionization source was developed to conduct trace analysis of organic compounds in liquids. Self-aspiration sampling is available where the samples are drawn into the vacuum chamber through a capillary with an extremely low flow rate (less than 1 μL/min), which minimizes sample consumption in each analysis to tens of micrograms. A pulsed gas-assisted inlet was designed and optimized to promote sample transmission in the tube and facilitate the cooling of ions, thereby improving instrument sensitivity. A limit of detection of 2 ppb could be achieved for 2,4-dimethylaniline in a methanol solution. The sampling system described in the present study is specifically suitable for a miniature photoionization ion trap mass spectrometer that can perform rapid and online analysis for liquid samples.
Doh, Eui Jeong; Paek, Seung-Ho; Lee, Guemsan; Lee, Mi-Young; Oh, Seung-Eun
2016-01-01
Several Artemisia species are used as herbal medicines including the dried aerial parts of Artemisia capillaris, which are used as Artemisiae Capillaris Herba (known as “Injinho” in Korean medicinal terminology and “Yin Chen Hao” in Chinese). In this study, we developed tools for distinguishing between A. capillaris and 11 other Artemisia species that grow and/or are cultured in China, Japan, and Korea. Based on partial nucleotide sequences in the internal transcribed spacer (ITS) that differ between the species, we designed primers to amplify a DNA marker for A. capillaris. In addition, to detect other Artemisia species that are contaminants of A. capillaris, we designed primers to amplify DNA markers of A. japonica, A. annua, A. apiacea, and A. anomala. Moreover, based on random amplified polymorphic DNA analysis, we confirmed that primers developed in a previous study could be used to identify Artemisia species that are sources of Artemisiae Argyi Folium and Artemisiae Iwayomogii Herba. By using these primers, we found that multiplex polymerase chain reaction (PCR) was a reliable tool to distinguish between A. capillaris and other Artemisia species and to identify other Artemisia species as contaminants of A. capillaris in a single PCR. PMID:27313651
Transcriptome Analysis of Core Dinoflagellates Reveals a Universal Bias towards "GC" Rich Codons.
Williams, Ernest; Place, Allen; Bachvaroff, Tsvetan
2017-04-27
Although dinoflagellates are a potential source of pharmaceuticals and natural products, the mechanisms for regulating and producing these compounds are largely unknown because of extensive post-transcriptional control of gene expression. One well-documented mechanism for controlling gene expression during translation is codon bias, whereby specific codons slow or even terminate protein synthesis. Approximately 10,000 annotatable genes from fifteen "core" dinoflagellate transcriptomes along a range of overall guanine and cytosine (GC) content were used for codonW analysis to determine the relative synonymous codon usage (RSCU) and the GC content at each codon position. GC bias in the analyzed dataset and at the third codon position varied from 51% and 54% to 66% and 88%, respectively. Codons poor in GC were observed to be universally absent, but bias was most pronounced for codons ending in uracil followed by adenine (UA). GC bias at the third codon position was able to explain low abundance codons as well as the low effective number of codons. Thus, we propose that a bias towards codons rich in GC bases is a universal feature of core dinoflagellates, possibly relating to their unique chromosome structure, and not likely a major mechanism for controlling gene expression.
LaPointe, M C; Chang, C H; Vedeckis, W V
1986-04-22
Gel-exclusion high-performance liquid chromatography (HPLC) has been used to separate the untransformed from the transformed glucocorticoid receptor (GC-R) extracted from mouse AtT-20 cells. With 200 mM potassium phosphate as the eluent, an efficient separation of the forms of the GC-R is attained in 15-20 min. The untransformed cytosolic GC-R elutes from the column with a Stokes radius (Rs) of 8.2-8.6 nm, as do the molybdate-stabilized GC-R, the purified untransformed GC-R, and the cross-linked cytosolic GC-R. GC-R transformed in vitro by either ammonium sulfate precipitation, KCl treatment, or G-25 chromatography elutes with an Rs of 5.7-6 nm. Also, GC-R extracted from the nucleus with either 0.3 M KCl or 2 mM sodium tungstate, or purified by two cycles of DNA-cellulose chromatography, has an Rs of 5.5-6.3 nm. The data are identical either in the presence or in the absence of 20 mM Na2MoO4, suggesting that molybdate is not causing aggregation to produce a larger Rs value than that of the native receptor. Vertical tube rotor sucrose gradient ultracentrifugation of cytosol produces three forms of the GC-R: 9.1 S, 5.2 S, and 3.8 S. Sequential analysis of the GC-R forms by HPLC and vertical tube rotor ultracentrifugation and vice versa allows for the hydrodynamic determination of molecular weight within a very short time period (2-3 h total).(ABSTRACT TRUNCATED AT 250 WORDS)
Analysis of poly-beta-hydroxybutyrate in environmental samples by GC-MS/MS.
Elhottová, D; Tríska, J; Petersen, S O; Santrůcková, H
2000-05-01
Application of gas chromatography-mass spectrometry (GC-MS) can significantly improve trace analyses of compounds in complex matrices from natural environments compared to gas chromatography only. A GC-MS/MS technique for determination of poly-beta-hydroxybutyrate (PHB), a bacterial storage compound, has been developed and used for analysis of two soils stored for up to 319 d, fresh samples of sewage sludge, as well as a pure culture of Bacillus megaterium. Specific derivatization of beta-hydroxybutyrate (3-OH C4:0) PHB monomer units by N-tert-butyl-dimethylsilyl-N-methyltrifluoracetamide (MTBSTFA) improved chromatographic and mass spectrometric properties of the analyte. The diagnostic fragmentation scheme of the derivates tert-butyldimethylsilyl ester and ether of beta-hydroxybutyric acid (MTBSTFA-HB) essential for the PHB identification was shown. The ion trap MS was used, therefore the scan gave the best sensitivity and with MS/MS the noise decreased, so the S/N was better and also with second fragmentation the amount of ions increased compared to SIM. The detection limit for MTBSTFA-HB by GC-MS/MS was about 10(-13) g microL(-1) of injected volume, while by GC (FID) and GC-MS (scan) it was around 10(-10) g microL(-1) of injected volume. Sensitivity of GC-MS/MS measurements of PHB in arable soil and activated sludge samples was down to 10 pg of PHB g(-1) dry matter. Comparison of MTBSTFA-HB detection in natural soil sample by GC (FID), GC-MS (scan) and by GC-MS/MS demonstrated potentials and limitations of the individual measurement techniques.
Li, Jun Hua; Chang, Ming Xian; Xue, Na Na; Nie, P
2013-08-01
Peptidoglycan recognition proteins (PGRPs), which are evolutionarily conserved from insects to mammals, recognize bacterial peptidoglycan (PGN) and function in antibacterial innate immunity. In this study, a short-form PGRP, designated as gcPGRP5 was identified from grass carp Ctenopharyngodon idella. The deduced amino acid sequence of gcPGRP5 is composed of 180 residues with a conserved PGRP domain at the C-terminus. The gcPGRP5 gene consists of four exons and three introns, spacing approximately 2.3 kb in genomic sequence. Phylogenetic analysis demonstrated that the gcPGRP5 is clustered with other PGRP-S identified in teleost fish. The gcPGRP5 is constitutively expressed in all organs/tissues examined, and its expression was significantly induced in CIK cells treated with lipoteichoic acid (LTA), polyinosinic polycytidylic acid (Poly I:C) and PGN. Fluorescence analysis showed that gcPGRP5 is distributed in cytoplasm of CIK cells, and cell lysates from CIK cells transfected with pTurbo-gcPGRP5-GFP and ptGFP1-gcPGRP5 plasmids display the binding activity and peptidoglycan-lytic amidase activity toward Lys-PGN from Staphylococcus aureus and Dap-PGN from Bacillus subtilis. Furthermore, heat-shock protein70 (Hsp70), and MyD88, an adaptor molecule in Toll-like receptor pathway, had an increased expression in CIK cells overexpressed with gcPGRP5. It is thus indicated that gcPGRP5 exhibits amidase activity, and also possesses roles in anti-stress, and in Toll-like receptor signaling pathway. Copyright © 2013 Elsevier Ltd. All rights reserved.
Kvitvang, Hans F N; Bruheim, Per
2015-08-15
Capillary ion chromatography (capIC) is the premium separation technology for low molecular phosphometabolites and nucleotides in biological extracts. Removal of excessive amounts of salt during sample preparation stages is a prerequisite to enable high quality capIC separation in combination with reproducible and sensitive MS detection. Existing sampling protocols for mammalian cells used for GC-MS and LC-MS metabolic profiling can therefore not be directly applied to capIC separations. Here, the development of a fast filtration sampling protocol for mammalian suspension cells tailored for quantitative profiling of the phosphometabolome on capIC-MS/MS is presented. The whole procedure from sampling the culture to transfer of filter to quenching and extraction solution takes less than 10s. To prevent leakage it is critical that a low vacuum pressure is applied, and satisfactorily reproducibility was only obtained by usage of a vacuum pressure controlling device. A vacuum of 60mbar was optimal for filtration of multiple myeloma Jjn-3 cell cultures through 5μm polyvinylidene (PVDF) filters. A quick deionized water (DI-water) rinse step prior to extraction was tested, and significantly higher metabolite yields were obtained during capIC-MS/MS analyses in this extract compared to extracts prepared by saline and reduced saline (25%) washing steps only. In addition, chromatographic performance was dramatically improved. Thus, it was verified that a quick DI-water rinse is tolerated by the cells and can be included as the final stage during filtration. Over 30 metabolites were quantitated in JJN-3 cell extracts by using the optimized sampling protocol with subsequent capIC-MS/MS analysis, and up to 2 million cells can be used in a single filtration step for the chosen filter and vacuum pressure. The technical set-up is also highly advantageous for microbial metabolome filtration protocols after optimization of vacuum pressure and washing solutions, and the reduced salt content of the extract will also improve the quality of LC-MS analysis due to lower salt adduct ion formation. Copyright © 2015 Elsevier B.V. All rights reserved.
Preston, Tom
2014-01-01
This paper discusses some of the recent improvements in instrumentation used for stable isotope tracer measurements in the context of measuring retinol stores, in vivo. Tracer costs, together with concerns that larger tracer doses may perturb the parameter under study, demand that ever more sensitive mass spectrometric techniques are developed. GCMS is the most widely used technique. It has high sensitivity in terms of sample amount and uses high resolution GC, yet its ability to detect low isotope ratios is limited by background noise. LCMSMS may become more accessible for tracer studies. Its ability to measure low level stable isotope tracers may prove superior to GCMS, but it is isotope ratio MS (IRMS) that has been designed specifically for low level stable isotope analysis through accurate analysis of tracer:tracee ratios (the tracee being the unlabelled species). Compound-specific isotope analysis, where GC is interfaced to IRMS, is gaining popularity. Here, individual 13C-labelled compounds are separated by GC, combusted to CO2 and transferred on-line for ratiometric analysis by IRMS at the ppm level. However, commercially-available 13C-labelled retinol tracers are 2 - 4 times more expensive than deuterated tracers. For 2H-labelled compounds, GC-pyrolysis-IRMS has now become more generally available as an operating mode on the same IRMS instrument. Here, individual compounds are separated by GC and pyrolysed to H2 at high temperature for analysis by IRMS. It is predicted that GC-pyrolysis-IRMS will facilitate low level tracer procedures to measure body retinol stores, as has been accomplished in the case of fatty acids and amino acids. Sample size requirements for GC-P-IRMS may exceed those of GCMS, but this paper discusses sample preparation procedures and predicts improvements, particularly in the efficiency of sample introduction.
Scaling analysis and SE simulation of the tilted cylinder-interface capillary interaction
NASA Astrophysics Data System (ADS)
Gao, S. Q.; Zhang, X. Y.; Zhou, Y. H.
2018-06-01
The capillary interaction induced by a tilted cylinder and interface is the basic configuration of many complex systems, such as micro-pillar arrays clustering, super-hydrophobicity of hairy surface, water-walking insects, and fiber aggregation. We systematically analyzed the scaling laws of tilt angle, contact angle, and cylinder radius on the contact line shape by SE simulation and experiment. The following in-depth analysis of the characteristic parameters (shift, stretch and distortion) of the deformed contact lines reveals the self-similar shape of contact line. Then a general capillary force scaling law is proposed to incredibly grasp all the simulated and experimental data by a quite straightforward ellipse approximation approach.
In-air PIXE analysis by means of glass capillary optics
NASA Astrophysics Data System (ADS)
Nebiki, Takuya; Kabir, M. Hasnat; Narusawa, Tadashi
2006-08-01
A novel technique to introduce high energy ion beams to atmospheric environment is presented, which enables in-air PIXE measurements. Slightly tapered glass capillary optics is applied to work as a differential pumping orifice as well as a focusing lens. The flux intensity is enhanced by at least one order of magnitude due to the focusing effect. Using capillaries of 10-20 μm outlet diameters, we obtain several hundreds pA of 4 MeV He2+ ion beam and apply it to PIXE analysis of the seabed sludge without any sample treatments. A comparison of spectra between wet and dry sludge samples suggests the usefulness of our new technique.
Zanchetti Meneghini, Leonardo; Rübensam, Gabriel; Claudino Bica, Vinicius; Ceccon, Amanda; Barreto, Fabiano; Flores Ferrão, Marco; Bergold, Ana Maria
2014-01-01
A simple and inexpensive method based on solvent extraction followed by low temperature clean-up was applied for determination of seven pyrethroids residues in bovine raw milk using gas chromatography coupled to tandem mass spectrometry (GC-MS/MS) and gas chromatography with electron-capture detector (GC-ECD). Sample extraction procedure was established through the evaluation of seven different extraction protocols, evaluated in terms of analyte recovery and cleanup efficiency. Sample preparation optimization was based on Doehlert design using fifteen runs with three different variables. Response surface methodologies and polynomial analysis were used to define the best extraction conditions. Method validation was carried out based on SANCO guide parameters and assessed by multivariate analysis. Method performance was considered satisfactory since mean recoveries were between 87% and 101% for three distinct concentrations. Accuracy and precision were lower than ±20%, and led to no significant differences (p < 0.05) between results obtained by GC-ECD and GC-MS/MS techniques. The method has been applied to routine analysis for determination of pyrethroid residues in bovine raw milk in the Brazilian National Residue Control Plan since 2013, in which a total of 50 samples were analyzed. PMID:25380457
Shellie, Robert; Marriott, Philip; Morrison, Paul
2004-09-01
The use of gas chromatography (GC)-mass spectrometry (MS), GC-time-of-flight MS (TOFMS), comprehensive two-dimensional GC (GCxGC)-flame ionization detection (FID), and GCxGC-TOFMS is discussed for the characterization of the eight important representative components, including Z-alpha-santalol, epi-alpha-bisabolol, Z-alpha-trans-bergamotol, epi-beta-santalol, Z-beta-santalol, E,E-farnesol, Z-nuciferol, and Z-lanceol, in the oil of west Australian sandalwood (Santalum spicatum). Single-column GC-MS lacks the resolving power to separate all of the listed components as pure peaks and allow precise analytical measurement of individual component abundances. With enhanced peak resolution capabilities in GCxGC, these components are sufficiently well resolved to be quantitated using flame ionization detection, following initial characterization of components by using GCxGC-TOFMS.
Schematic for efficient computation of GC, GC3, and AT3 bias spectra of genome
Rizvi, Ahsan Z; Venu Gopal, T; Bhattacharya, C
2012-01-01
Selection of synonymous codons for an amino acid is biased in protein translation process. This biased selection causes repetition of synonymous codons in structural parts of genome that stands for high N/3 peaks in DNA spectrum. Period-3 spectral property is utilized here to produce a 3-phase network model based on polyphase filterbank concepts for derivation of codon bias spectra (CBS). Modification of parameters in this model can produce GC, GC3, and AT3 bias spectra. Complete schematic in LabVIEW platform is presented here for efficient and parallel computation of GC, GC3, and AT3 bias spectra of genomes alongwith results of CBS patterns. We have performed the correlation coefficient analysis of GC, GC3, and AT3 bias spectra with codon bias patterns of CBS for biological and statistical significance of this model. PMID:22368390
Schematic for efficient computation of GC, GC3, and AT3 bias spectra of genome.
Rizvi, Ahsan Z; Venu Gopal, T; Bhattacharya, C
2012-01-01
Selection of synonymous codons for an amino acid is biased in protein translation process. This biased selection causes repetition of synonymous codons in structural parts of genome that stands for high N/3 peaks in DNA spectrum. Period-3 spectral property is utilized here to produce a 3-phase network model based on polyphase filterbank concepts for derivation of codon bias spectra (CBS). Modification of parameters in this model can produce GC, GC3, and AT3 bias spectra. Complete schematic in LabVIEW platform is presented here for efficient and parallel computation of GC, GC3, and AT3 bias spectra of genomes alongwith results of CBS patterns. We have performed the correlation coefficient analysis of GC, GC3, and AT3 bias spectra with codon bias patterns of CBS for biological and statistical significance of this model.
Wang, Mei; Chen, Bin; Sun, Xiao-Xian; Zhao, Xiang-Dong; Zhao, Yuan-Yuan; Sun, Li; Xu, Chang-Gen; Shen, Bo; Su, Zhao-Liang; Xu, Wen-Rong; Zhu, Wei
2017-12-01
Gastric cancer tissue-derived mesenchymal stem cells (GC-MSCs) are important resident stromal cells in the tumor microenvironment (TME) and have been shown to play a key role in gastric cancer progression. Whether GC-MSCs exert a tumor-promoting function by affecting anti-tumor immunity is still unclear. In this study, we used GC-MSC conditioned medium (GC-MSC-CM) to pretreat peripheral blood mononuclear cells (PBMCs) from healthy donors. We found that GC-MSC-CM pretreatment markedly reversed the inhibitory effect of PBMCs on gastric cancer growth in vivo, but did not affect functions of PBMCs on gastric cancer cell proliferation, cell cycle and apoptosis in vitro. PBMCs pretreated with GC-MSC-CM significantly promoted gastric cancer migration and epithelial-mesenchymal transition in vitro and liver metastases in vivo. Flow cytometry analysis showed that GC-MSC-CM pretreatment increased the proportion of Treg cells and reduced that of Th17 cells in PBMCs. CFSE labeling and naïve CD4 + T cells differentiation analysis revealed that GC-MSC-CM disrupted the Treg/Th17 balance in PBMCs by suppressing Th17 cell proliferation and inducing differentiation of Treg cells. Overall, our collective results indicate that GC-MSCs impair the anti-tumor immune response of PBMCs through disruption of Treg/Th17 balance, thus providing new evidence that gastric cancer tissue-derived MSCs contribute to the immunosuppressive TME. Copyright © 2017 Elsevier Inc. All rights reserved.
Han, Mei; Ma, Lanying; Qu, Yanli; Tang, Yong
2017-08-01
To explore the clinicopathological significance of ATM gene in the occurrence and prognosis of gastric cancer (GC) from different nationalities in Xinjiang. The expression of ATM in 385 patients with GC (including 98 Uygurs, 231 Hans and 56 Kazaks) and its corresponding adjacent tissues were examined by quantitative real-time polymerase chain reaction (qRT-PCR) and immunohistochemistry assay to, analyze its correlations with clinicopathological features and prognosis of GC. The ATM expression in GC tissues was significantly decreased when compared to that in adjacent normal tissues of Uygur, Han and Kazak patients in Xinjiang, while Uygurs and Kazaks were much lower than Hans in the ATM expression of GC tissues (all P<0.05). Kaplan-Meier analysis showed that Uygur and Kazak patients with ATM-negative tumors had a markedly lower survival rate than patients in Hans (P=0.028), and GC patients with ATM negative expression presented more unfavorable overall survival rate than those with positive expression among the three different nationalities (all P<0.05). Multivariate Cox regression analysis revealed that nationality, ATM expression, TNM staging, depth of invasion, and lymph node metastasis were independent factors affecting the prognosis of GC patients in Xinjiang (all P<0.05). ATM was downregulated in GC patients in Xinjiang, especially for Uygurs and Kazaks, which suggested ATM to be an independent indicator of prognosis for GC therapy. Copyright © 2017 Elsevier GmbH. All rights reserved.
2012-03-01
enhanced accumulation of total lipids evaluated by Bodipy staining and NMR analysis. A major finding in this report is that glycolytic and lipogenic enzyme...total lipid component using NMR Metabolomics showed significant increases in the quantity of intracellular (CH2)n and (CH3) acyl chains (i.e. fatty...Mass Spectrometry (GC-MS) methods were developed. GC-MS differs from NMR analysis of lipid fractions in that GC-MS distinguishes between fatty acids
Duquesnoy, Emilie; Marongiu, Bruno; Castola, Vincent; Piras, Alessandra; Porcedda, Silvia; Casanova, Joseph
2010-12-01
Two samples (leaves and twigs) of Abies alba Miller from Corsica were extracted using supercritical CO2 and their chemical compositions were compared with those of the essential oils obtained from the same batch of plant material. In total 45 components were identified using combined analysis by GC (RI), GC-MS and 13C NMR. It was observed that the contents of monoterpenes (mainly represented by limonene, alpha-pinene and camphene) were significantly lower in the supercritical fluid extract (SFE) than in the essential oil (EO). Conversely, the proportions of sesquiterpenes were much higher in CO2 extracts than in essential oils (around 30% vs 4%). Cis-abienol, a diterpene alcohol, was identified only in SFE, and the proportions of this constituent (7.5% and 17.3%) were determined using quantitative 13C NMR since it was under estimated using the standard conditions of GC.
Development of a GC/Quadrupole-Orbitrap Mass Spectrometer, Part I: Design and Characterization
2015-01-01
Identification of unknown compounds is of critical importance in GC/MS applications (metabolomics, environmental toxin identification, sports doping, petroleomics, and biofuel analysis, among many others) and remains a technological challenge. Derivation of elemental composition is the first step to determining the identity of an unknown compound by MS, for which high accuracy mass and isotopomer distribution measurements are critical. Here, we report on the development of a dedicated, applications-grade GC/MS employing an Orbitrap mass analyzer, the GC/Quadrupole-Orbitrap. Built from the basis of the benchtop Orbitrap LC/MS, the GC/Quadrupole-Orbitrap maintains the performance characteristics of the Orbitrap, enables quadrupole-based isolation for sensitive analyte detection, and includes numerous analysis modalities to facilitate structural elucidation. We detail the design and construction of the instrument, discuss its key figures-of-merit, and demonstrate its performance for the characterization of unknown compounds and environmental toxins. PMID:25208235
Environmental and forensic applications of field-portable GC-MS: an overview.
Eckenrode, B A
2001-06-01
GC-MS can provide analytical information that is most reliable for many types of organic analyses. As field-portable GC-MS analytical systems evolve, the application scenarios have diversified as well. With the development of rugged fieldable systems, these instruments were demonstrated to be usable in the harsh environment of the jungle and in chemical demilitarization or military reconnaissance situations. Continuous unattended operations of a GC-MS for 12- or 24-hour monitoring applications in the field have been shown to be possible. A real-time algorithm strategy is proposed, which can be developed to aid in the advancement of field-portable mass spectrometry applied to chemical warfare agent analysis in military vehicles and can be used to raise the standard for field data quality. Each of these capabilities is discussed with the intent on reviewing analysis situations that can be expanded because of developments in field GC-MS instrumentation.
Masood, Athar; Stark, Ken D; Salem, Norman
2005-10-01
Conventional sample preparation for fatty acid analysis is a complicated, multiple-step process, and gas chromatography (GC) analysis alone can require >1 h per sample to resolve fatty acid methyl esters (FAMEs). Fast GC analysis was adapted to human plasma FAME analysis using a modified polyethylene glycol column with smaller internal diameters, thinner stationary phase films, increased carrier gas linear velocity, and faster temperature ramping. Our results indicated that fast GC analyses were comparable to conventional GC in peak resolution. A conventional transesterification method based on Lepage and Roy was simplified to a one-step method with the elimination of the neutralization and centrifugation steps. A robotics-amenable method was also developed, with lower methylation temperatures and in an open-tube format using multiple reagent additions. The simplified methods produced results that were quantitatively similar and with similar coefficients of variation as compared with the original Lepage and Roy method. The present streamlined methodology is suitable for the direct fatty acid analysis of human plasma, is appropriate for research studies, and will facilitate large clinical trials and make possible population studies.
Nüsslein, Klaus; Tiedje, James M.
1999-01-01
The change in vegetative cover of a Hawaiian soil from forest to pasture led to significant changes in the composition of the soil bacterial community. DNAs were extracted from both soil habitats and compared for the abundance of guanine-plus-cytosine (G+C) content, by analysis of abundance of phylotypes of small-subunit ribosomal DNA (SSU rDNA) amplified from fractions with 63 and 35% G+C contents, and by phylogenetic analysis of the dominant rDNA clones in the 63% G+C content fraction. All three methods showed differences between the forest and pasture habitats, providing evidence that vegetation had a strong influence on microbial community composition at three levels of taxon resolution. The forest soil DNA had a peak in G+C content of 61%, while the DNA of the pasture soil had a peak in G+C content of 67%. None of the dominant phylotypes found in the forest soil were detected in the pasture soil. For the 63% G+C fraction SSU rDNA sequence analysis of the three most dominant members revealed that their phyla changed from Fibrobacter and Syntrophomonas assemblages in the forest soil to Burkholderia and Rhizobium–Agrobacterium assemblages in the pasture soil. PMID:10427058
Antonios, Tarek F T; Nama, Vivek; Wang, Duolao; Manyonda, Isaac T
2013-09-01
Preeclampsia is a major cause of maternal and neonatal mortality and morbidity. The incidence of preeclampsia seems to be rising because of increased prevalence of predisposing disorders, such as essential hypertension, diabetes, and obesity, and there is increasing evidence to suggest widespread microcirculatory abnormalities before the onset of preeclampsia. We hypothesized that quantifying capillary rarefaction could be helpful in the clinical prediction of preeclampsia. We measured skin capillary density according to a well-validated protocol at 5 consecutive predetermined visits in 322 consecutive white women, of whom 16 subjects developed preeclampsia. We found that structural capillary rarefaction at 20-24 weeks of gestation yielded a sensitivity of 0.87 with a specificity of 0.50 at the cutoff of 2 capillaries/field with the area under the curve of the receiver operating characteristic value of 0.70, whereas capillary rarefaction at 27-32 weeks of gestation yielded a sensitivity of 0.75 and a higher specificity of 0.77 at the cutoff of 8 capillaries/field with area under the curve of the receiver operating characteristic value of 0.82. Combining capillary rarefaction with uterine artery Doppler pulsatility index increased the sensitivity and specificity of the prediction. Multivariable analysis shows that the odds of preeclampsia are increased in women with previous history of preeclampsia or chronic hypertension and in those with increased uterine artery Doppler pulsatility index, but the most powerful and independent predictor of preeclampsia was capillary rarefaction at 27-32 weeks. Quantifying structural rarefaction of skin capillaries in pregnancy is a potentially useful clinical marker for the prediction of preeclampsia.
Noninvasive imaging of human foveal capillary network using dual-conjugate adaptive optics.
Popovic, Zoran; Knutsson, Per; Thaung, Jörgen; Owner-Petersen, Mette; Sjöstrand, Johan
2011-04-22
To demonstrate noninvasive imaging of human foveal capillary networks with a high-resolution, wide-field, dual-conjugate adaptive optics (DCAO) imaging instrument. The foveal capillary networks of five healthy subjects with no previous history of ocular or neurologic disease or surgery were imaged with a novel high-resolution, wide-field DCAO instrument. The foveal avascular zone (FAZ) in each image was defined using a manual procedure. An automated algorithm based on publicly available and custom-written software was used to identify vessels and extract morphologic FAZ and vessel parameters. Capillary densities were calculated in two annular regions of interest (ROIs) outside the FAZ (500 μm and 750 μm outer radius from the foveal center) and in the superior, inferior, temporal, and nasal quadrants within the two ROIs. Mean FAZ area was 0.302 ± 0.100 mm(2), and mean capillary density (length/area) in the inner ROI was 38.0 ± 4.0 mm(-1) and 36.4 ± 4.0 mm(-1) in the outer ROI. The difference in ROI capillary density was not significant. There was no significant difference in quadrant capillary density within the two ROIs or between quadrants irrespective of ROI. The authors have demonstrated a technique for noninvasive imaging and semiautomated detection and analysis of foveal capillaries. In comparison with other studies, their method yielded lower capillary densities than histology but similar results to the current clinical gold standard, fluorescein angiography. The increased field of view of the DCAO instrument opens up new possibilities for high-resolution noninvasive clinical imaging of foveal capillaries.
Capillary Rise: Validity of the Dynamic Contact Angle Models.
Wu, Pingkeng; Nikolov, Alex D; Wasan, Darsh T
2017-08-15
The classical Lucas-Washburn-Rideal (LWR) equation, using the equilibrium contact angle, predicts a faster capillary rise process than experiments in many cases. The major contributor to the faster prediction is believed to be the velocity dependent dynamic contact angle. In this work, we investigated the dynamic contact angle models for their ability to correct the dynamic contact angle effect in the capillary rise process. We conducted capillary rise experiments of various wetting liquids in borosilicate glass capillaries and compared the model predictions with our experimental data. The results show that the LWR equations modified by the molecular kinetic theory and hydrodynamic model provide good predictions on the capillary rise of all the testing liquids with fitting parameters, while the one modified by Joos' empirical equation works for specific liquids, such as silicone oils. The LWR equation modified by molecular self-layering model predicts well the capillary rise of carbon tetrachloride, octamethylcyclotetrasiloxane, and n-alkanes with the molecular diameter or measured solvation force data. The molecular self-layering model modified LWR equation also has good predictions on the capillary rise of silicone oils covering a wide range of bulk viscosities with the same key parameter W(0), which results from the molecular self-layering. The advantage of the molecular self-layering model over the other models reveals the importance of the layered molecularly thin wetting film ahead of the main meniscus in the energy dissipation associated with dynamic contact angle. The analysis of the capillary rise of silicone oils with a wide range of bulk viscosities provides new insights into the capillary dynamics of polymer melts.
Optical coherence tomography angiography-based capillary velocimetry
NASA Astrophysics Data System (ADS)
Wang, Ruikang K.; Zhang, Qinqin; Li, Yuandong; Song, Shaozhen
2017-06-01
Challenge persists in the field of optical coherence tomography (OCT) when it is required to quantify capillary blood flow within tissue beds in vivo. We propose a useful approach to statistically estimate the mean capillary flow velocity using a model-based statistical method of eigendecomposition (ED) analysis of the complex OCT signals obtained with the OCT angiography (OCTA) scanning protocol. ED-based analysis is achieved by the covariance matrix of the ensemble complex OCT signals, upon which the eigenvalues and eigenvectors that represent the subsets of the signal makeup are calculated. From this analysis, the signals due to moving particles can be isolated by employing an adaptive regression filter to remove the eigencomponents that represent static tissue signals. The mean frequency (MF) of moving particles can be estimated by the first lag-one autocorrelation of the corresponding eigenvectors. Three important parameters are introduced, including the blood flow signal power representing the presence of blood flow (i.e., OCTA signals), the MF indicating the mean velocity of blood flow, and the frequency bandwidth describing the temporal flow heterogeneity within a scanned tissue volume. The proposed approach is tested using scattering phantoms, in which microfluidic channels are used to simulate the functional capillary vessels that are perfused with the scattering intralipid solution. The results indicate a linear relationship between the MF and mean flow velocity. In vivo animal experiments are also conducted by imaging mouse brain with distal middle cerebral artery ligation to test the capability of the method to image the changes in capillary flows in response to an ischemic insult, demonstrating the practical usefulness of the proposed method for providing important quantifiable information about capillary tissue beds in the investigations of neurological conditions in vivo.
Development and study of a heat pipe with dielectric properties
NASA Astrophysics Data System (ADS)
Semena, M. G.; Gershuni, A. N.; Chepurnoi, A. B.
Requirements for the structural elements of heat pipes with dielectric properties are examined. To obtain information necessary for the thermal analysis of heat pipes, a study is made of the capillary-transport characteristics of a dielectric capillary structure consisting of quartz fibers; the capillary pressure and the liquid penetration coefficient are determined. The results of the study are used to develop dielectric heat pipes for the cooling of a vacuum electronic instrument. Experimentally determined characteristics of the heat pipes are presented.
Detection Method of TOXOPLASMA GONDII Tachyzoites
NASA Astrophysics Data System (ADS)
Eassa, Souzan; Bose, Chhanda; Alusta, Pierre; Tarasenko, Olga
2011-06-01
Tachyzoites are considered to be the most important stage of Toxoplasma gondii which causes toxoplasmosis. T. gondii is, an obligate intracellular parasite which infects a wide range of cells. The present study was designed to develop a method for an early detection of T. gondii tachyzoites. The method comprised of a binding assay which was analyzed using principal component and cluster analysis. Our data showed that glycoconjugates GC1, GC2, GC3 and GC10 exhibit a significantly higher binding affinity for T. gondii tachyzoites as compared to controls (T. gondii only, PAA only, GC 1, 2, 3, and 10 only).
HIGH SPEED GC/MS FOR AIR ANALYSIS
A high speed GC/MS system consisting of a gas chromatograph equipped with a narrow bandwidth injection accessory and using a time-of-flight mass spectrometer detector has been adapted for analysis of ambient whole air samples which have been collected in passivated canisters. ...
Factors affecting the separation performance of proteins in capillary electrophoresis.
Zhu, Yueping; Li, Zhenqing; Wang, Ping; Shen, Lisong; Zhang, Dawei; Yamaguchi, Yoshinori
2018-04-15
Capillary electrophoresis (CE) is an effective tool for protein separation and analysis. Compared with capillary gel electrophoresis (CGE), non-gel sieving capillary electrophoresis (NGSCE) processes the superiority on operation, repeatability and automaticity. Herein, we investigated the effect of polymer molecular weight and concentration, electric field strength, and the effective length of the capillary on the separation performance of proteins, and find that (1) polymer with high molecular weight and concentration favors the separation of proteins, although concentrated polymer hinders its injection into the channel of the capillary due to its high viscosity. (2) The resolution between the adjacent proteins decreases with the increase of electric field strength. (3) When the effective length of the capillary is long, the separation performance improves at the cost of separation time. (4) 1.4% (w/v) hydroxyethyl cellulose (HEC), 100 V/cm voltage and 12 cm effective length offers the best separation for the proteins with molecular weight from 14,400 Da to 97,400 Da. Finally, we employed the optimal electrophoretic conditions to resolve Lysozyme, Ovalbumin, BSA and their mixtures, and found that they were baseline resolved within 15 min. Copyright © 2018 Elsevier B.V. All rights reserved.
Chen, Qinqin; Song, Jianxin; Bi, Jinfeng; Meng, Xianjun; Wu, Xinye
2018-03-01
Volatile profile of ten different varieties of fresh jujubes was characterized by HS-SPME/GC-MS (headspace solid phase micro-extraction combined with gas chromatography-mass spectrometry) and E-nose (electronic nose). GC-MS results showed that a total of 51 aroma compounds were identified in jujubes, hexanoic acid, hexanal, (E)-2-hexenal, (Z)-2-heptenal, benzaldehyde and (E)-2-nonenal were the main aroma components with contributions that over 70%. Differentiation of jujube varieties was conducted by cluster analysis of GC-MS data and principal component analysis & linear discriminant analysis of E-nose data. Both results showed that jujubes could be mainly divided into two groups: group A (JZ, PDDZ, JSXZ and LWZZ) and group B (BZ, YZ, MZ, XZ and DZ). There were significant differences in contents of alcohols, acids and aromatic compounds between group A and B. GC-MS coupled with E-nose could be a fast and accurate method to identify the general flavor difference in different varieties of jujubes. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Larson, Evan A.; Hutchinson, Carolyn P.; Lee, Young Jin
2018-06-01
Dopant-assisted atmospheric pressure chemical ionization (dAPCI) is a soft ionization method rarely used for gas chromatography-mass spectrometry (GC-MS). The current study combines GC-dAPCI with tandem mass spectrometry (MS/MS) for analysis of a complex mixture such as lignin pyrolysis analysis. To identify the structures of volatile lignin pyrolysis products, collision-induced dissociation (CID) MS/MS using a quadrupole time-of-flight mass spectrometer (QTOFMS) and pseudo MS/MS through in-source collision-induced dissociation (ISCID) using a single stage TOFMS are utilized. To overcome the lack of MS/MS database, Compound Structure Identification (CSI):FingerID is used to interpret CID spectra and predict best matched structures from PubChem library. With this approach, a total of 59 compounds were positively identified in comparison to only 22 in NIST database search of GC-EI-MS dataset. This study demonstrates the effectiveness of GC-dAPCI-MS/MS to overcome the limitations of traditional GC-EI-MS analysis when EI-MS database is not sufficient. [Figure not available: see fulltext.
Unice, Kenneth M; Kreider, Marisa L; Panko, Julie M
2012-11-08
Pyrolysis(pyr)-GC/MS analysis of characteristic thermal decomposition fragments has been previously used for qualitative fingerprinting of organic sources in environmental samples. A quantitative pyr-GC/MS method based on characteristic tire polymer pyrolysis products was developed for tread particle quantification in environmental matrices including soil, sediment, and air. The feasibility of quantitative pyr-GC/MS analysis of tread was confirmed in a method evaluation study using artificial soil spiked with known amounts of cryogenically generated tread. Tread concentration determined by blinded analyses was highly correlated (r2 ≥ 0.88) with the known tread spike concentration. Two critical refinements to the initial pyrolysis protocol were identified including use of an internal standard and quantification by the dimeric markers vinylcyclohexene and dipentene, which have good specificity for rubber polymer with no other appreciable environmental sources. A novel use of deuterated internal standards of similar polymeric structure was developed to correct the variable analyte recovery caused by sample size, matrix effects, and ion source variability. The resultant quantitative pyr-GC/MS protocol is reliable and transferable between laboratories.
Pojjanapornpun, Siriluck; Nolvachai, Yada; Aryusuk, Kornkanok; Kulsing, Chadin; Krisnangkura, Kanit; Marriott, Philip J
2018-02-17
New generation inert ionic liquid (iIL) GC columns IL60i, IL76i and IL111i, comprising phosphonium or imidazolium cationic species, were investigated for separation of fatty acid methyl esters (FAME). In general, the iIL phases provide comparable retention times to their corresponding conventional columns, with only minor selectivity differences. The average tailing factors and peak widths were noticeably improved (reduced) for IL60i and IL76i, while they were slightly improved for IL111i. Inert IL phase columns were coupled with conventional IL columns in comprehensive two-dimensional GC (GC × GC) with a solid-state modulator which offers variable modulation temperature (T M ), programmable T M during analysis and trapping stationary phase material during the trap/release (modulation) process, independent of oven T and column sets. Although IL phases are classified as polar, relative polarity of the two phases comprising individual GC × GC column sets permits combination of less-polar IL/polar IL and polar IL/less-polar IL column sets; it was observed that a polar/less-polar column set provided better separation of FAME. A higher first dimension ( 1 D) phase polarity combined with a lower 2 D phase polarity, for instance 1 D IL111i with 2 D IL59 gave the best result; the greater difference in 1 D/ 2 D phase polarity results in increasing occupancy of peak area in the 2D space. The IL111i/IL59 column set was selected for analysis of fatty acids in fat and oil products (butter, margarine, fish oil and canola oil). Compared with the conventional IL111, IL111i showed reduced column bleed which makes this more suited to GC × GC analysis of FAME. The proposed method offers a fast profiling approach with good repeatability of analysis of FAME.
Diagnostic value of circulating microRNAs for gastric cancer in Asian populations: a meta-analysis.
Liu, Lihua; Wang, Shan; Cao, Xiutang; Liu, Jianchao
2014-12-01
Gastric cancer (GC) accounts for one of the highest mortality worldwide and particularly in East Asia. Many studies have reported on the potential value of microRNAs (miRNAs) detection for diagnosing GC, but their results have proven inconclusive. The present meta-analysis was conducted to assess the diagnostic value of circulating miRNAs for GC diagnosis. A literature search was carried out in databases (PubMed, Embase, Web of Science, The Cochrane Library, and CNKI) and other sources using combinations of keywords relating to GC, miRNAs, and diagnosis. The values of sensitivity, specificity, positive likelihood ratios (PLR), negative likelihood ratios (NLR), and diagnostic odds ratio (DOR) reported in individual studies were pooled using random-effects models. Potential sources of heterogeneity were assessed with subgroup and meta-regression analyses. The summary receiver operating characteristic (SROC) curve and the area under the curve (AUC) were used to assess the diagnosis accuracy of miRNAs. This meta-analysis included 1,279 patients with GC and 954 healthy controls from 20 publications. The pooled sensitivity, specificity, PLR, NLR, DOR, and AUC were 0.78 (95 % CI: 0.73-0.81), 0.80 (95 % CI: 0.76-0.84), 4.0 (95 % CI: 3.1-6.0), 0.28 (95 % CI: 0.23-0.34), 14 (95 % CI: 10-21), and 0.86 (95 % CI: 0.83-0.89), respectively. Subgroup analyses showed that early stages (I and II) GC were more easily detected than later stages and that multiple miRNAs assays were more accurate than single miRNA assays. Our meta-analysis suggests that miRNAs have a high diagnostic value for GC, especially in its early stages (I and II). In addition, multiple miRNAs assays have a better diagnosis value than single miRNA assays. In conclusion, circulating miRNAs might be used as noninvasive biomarkers for the confirmation of GC detection in Asian populations.
1,25D3 enhances antitumor activity of gemcitabine and cisplatin in human bladder cancer models
Ma, Yingyu; Yu, Wei-Dong; Trump, Donald L.; Johnson, Candace S.
2010-01-01
Background 1,25 dihydroxyvitamin D3 (1,25D3) potentiates the cytotoxic effects of several common chemotherapeutic agents. The combination of gemcitabine and cisplatin (GC) is a current standard chemotherapy regimen for bladder cancer. We investigated whether 1,25D3 could enhance the antitumor activity of GC in bladder cancer model systems. Methods Human bladder cancer T24 and UMUC3 cells were pretreated with 1,25D3 followed by GC. Apoptosis were assessed by annexin V staining. Caspase activation was examined by immunoblot analysis and substrate-based caspase activity assay. The cytotoxic effects were examined using MTT and in vitro clonogenic assay. p73 protein levels were assessed by immunoblot analysis. Knockdown of p73 was achieved by siRNA. The in vivo antitumor activity was assessed by in vivo excision clonogenic assay and tumor regrowth delay in the T24 xenograft model. Results 1,25D3 pretreatment enhanced GC-induced apoptosis and the activities of caspases- 8, 9 and 3 in T24 and UMUC3 cells. 1,25D3 synergistically reduced GC-suppressed surviving fraction in T24 cells. 1,25D3, gemcitabine, or cisplatin induced p73 accumulation, which was enhanced by GC or 1,25D3 and GC. p73 expression was lower in human primary bladder tumor tissue compared with adjacent normal tissue. Knockdown of p73 increased clonogenic capacity of T24 cells treated with 1,25D3, GC or 1,25D3 and GC. 1,25D3 and GC combination enhanced tumor regression compared with 1,25D3 or GC alone. Conclusions 1,25D3 potentiates GC-mediated growth inhibition in human bladder cancer models in vitro and in vivo, which involves p73 induction and apoptosis. PMID:20564622
Hosono, Osamu; Yoshikawa, Noritada; Shimizu, Noriaki; Kiryu, Shigeru; Uehara, Masaaki; Kobayashi, Hiroshi; Matsumiya, Ryo; Kuribara, Akiko; Maruyama, Takako; Tanaka, Hirotoshi
2015-03-01
To determine the availability of bioelectrical impedance analysis (BIA), computed tomography (CT), and magnetic resonance imaging (MRI) for measurement of skeletal muscle mass in patients with rheumatic diseases and quantitatively assess skeletal muscle loss after glucocorticoid (GC) treatment. The data from 22 patients with rheumatic diseases were retrospectively obtained. The muscle mass of body segments was measured with a BIA device in terms of skeletal muscle mass index (SMI). Cross-sectional area (CSA) was obtained from CT and MRI scans at the mid-thigh level using the image analysis program. We further assessed the data of three different measurements before and after GC treatment in 7 patients with rheumatic diseases. SMI of whole body was significantly correlated with estimated muscle volume and mid-thigh muscle CSA with CT and MRI (p < 0.01). Significant correlations between SMI and mid-thigh muscle CSA of each leg were also found (p < 0.01). All the three measurements were negatively correlated with GC dosage (p < 0.01). Significant decline in mid-thigh muscle CSA with CT and MRI was found after GC treatment in 7 patients (p < 0.02). Those patients showed significant decline in SMI of whole body after GC treatment, but not in SMI of each leg. On the other hand, significant correlations between mid-thigh muscle CSA with CT and MRI were found before and after GC treatment (p < 0.01). GC-related skeletal muscle loss could be quantitatively assessed with BIA, CT, or MRI in patients with rheumatic diseases, and CT and MRI appeared to be more accurate than BIA.
Tu, Huakang; Sun, Liping; Dong, Xiao; Gong, Yuehua; Xu, Qian; Jing, Jingjing; Bostick, Roberd M; Wu, Xifeng; Yuan, Yuan
2017-05-01
We aimed to assess a serological biopsy using five stomach-specific circulating biomarkers-pepsinogen I (PGI), PGII, PGI/II ratio, anti-Helicobacter pylori (H. pylori) antibody, and gastrin-17 (G-17)-for identifying high-risk individuals and predicting risk of developing gastric cancer (GC). Among 12,112 participants with prospective follow-up from an ongoing population-based screening program using both serology and gastroscopy in China, we conducted a multi-phase study involving a cross-sectional analysis, a follow-up analysis, and an integrative risk prediction modeling analysis. In the cross-sectional analysis, the five biomarkers (especially PGII, the PGI/II ratio, and H. pylori sero-positivity) were associated with the presence of precancerous gastric lesions or GC at enrollment. In the follow-up analysis, low PGI levels and PGI/II ratios were associated with higher risk of developing GC, and both low (<0.5 pmol/l) and high (>4.7 pmol/l) G-17 levels were associated with higher risk of developing GC, suggesting a J-shaped association. In the risk prediction modeling analysis, the five biomarkers combined yielded a C statistic of 0.803 (95% confidence interval (CI)=0.789-0.816) and improved prediction beyond traditional risk factors (C statistic from 0.580 to 0.811, P<0.001) for identifying precancerous lesions at enrollment, and higher serological biopsy scores based on the five biomarkers at enrollment were associated with higher risk of developing GC during follow-up (P for trend <0.001). A serological biopsy composed of the five stomach-specific circulating biomarkers could be used to identify high-risk individuals for further diagnostic gastroscopy, and to stratify individuals' risk of developing GC and thus to guide targeted screening and precision prevention.
Kim, Jeongseon; Kang, Moonsu; Lee, Jung-Sug; Inoue, Manami; Sasazuki, Shizuka; Tsugane, Shoichiro
2011-01-01
Soy food is known to contribute greatly to a reduction in the risk of gastric cancer (GC). However, both Japanese and Korean populations have high incidence rates of GC despite the consumption of a wide variety of soy foods. One primary reason is that they consume fermented rather than non-fermented soy foods. In order to assess the varying effects of fermented and non-fermented soy intake on GC risk in these populations, we conducted a meta-analysis of published reports. Twenty studies assessing the effect of the consumption of fermented soy food on GC risk were included, and 17 studies assessing the effect of the consumption of non-fermented soy food on GC risk were included. We found that a high intake of fermented soy foods was significantly associated with an increased risk of GC (odds ratio [OR] = 1.22, 95% confidence interval [CI] = 1.02-1.44, I(2) = 71.48), whereas an increased intake of non-fermented soy foods was significantly associated with a decreased risk of GC (overall summary OR = 0.64, 95% CI = 0.54-0.77, I(2) = 64.27). These findings show that a high level of consumption of non-fermented soy foods, rather than fermented soy foods, is important in reducing GC risk. © 2010 Japanese Cancer Association.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reddy, Christopher; Nelson, Robert
The development of comprehensive two-dimensional gas chromatography (GC x GC) has expanded the analytical window for studying complex mixtures like oil. Compared to traditional gas chromatography, this technology separates and resolves at least an order of magnitude more compounds, has a much larger signal to noise ratio, and sorts compounds based on their chemical class; hence, providing highly refined inventories of petroleum hydrocarbons in geochemical samples that was previously unattainable. In addition to the increased resolution afforded by GC x GC, the resulting chromatograms have been used to estimate the liquid vapor pressures, aqueous solubilities, octanol-water partition coefficients, and vaporizationmore » enthalpies of petroleum hydrocarbons. With these relationships, powerful and incisive analyses of phase-transfer processes affecting petroleum hydrocarbon mixtures in the environment are available. For example, GC x GC retention data has been used to quantitatively deconvolve the effects of phase transfer processes such as water washing and evaporation. In short, the positive attributes of GC x GC-analysis have led to a methodology that has revolutionized the analysis of petroleum hydrocarbons. Overall, this research has opened numerous fields of study on the biogeochemical "genetics" (referred to as petroleomics) of petroleum samples in both subsurface and surface environments. Furthermore, these new findings have already been applied to the behavior of oil at other seeps as well, for petroleum exploration and oil spill studies.« less
NASA Astrophysics Data System (ADS)
Ji, Mengxia; Di, Jun; Ge, Yuping; Xia, Jiexiang; Li, Huaming
2017-08-01
A novel visible-light-driven 2D-2D graphene-like g-C3N4/ultrathin Bi4O5Br2 photocatalyst was prepared via a facile solvothermal method in the presence of reactable ionic liquid 1-hexadecyl-3-methylimidazolium bromide ([C16mim]Br) for the first time. FT-IR, XPS and TEM analysis results demonstrated the successful introduction of the 2D graphene-like g-C3N4 material to the Bi4O5Br2 system. DRS and BET analysis results indicated the existence of the g-C3N4 could lead to the broaden absorption edge and larger surface area of the ultrathin Bi4O5Br2 nanosheets. The electrochemical analysis implied a fast transfer of the interfacial electrons and low recombination rate of photogenerated charge carriers in g-C3N4/Bi4O5Br2, which could be assigned to the sufficient and tight contact between ultrathin Bi4O5Br2 and graphene-like g-C3N4. The quinolone antibiotic ciprofloxacin (CIP) was chosen as the target pollutant to evaluate the photocatalytic performance of the as-prepared samples under visible light irradiation. 1 wt% g-C3N4/Bi4O5Br2 composite exhibited the highest photocatalytic degradation performance among all of the as-prepared photocatalysts. The enhancement of photocatalytic activity was attributed to the maximum contact between graphene-like g-C3N4 and ultrathin Bi4O5Br2 material with matched energy band structure, which enable the efficient charge seperation. A possible photocatalytic mechanism also was proposed.
S-Adenosylhomocysteine Assay in the Urine by Capillary Electrophoresis.
Luzyanin, B P; Ivanov, A V; Viryus, E D; Kubatiev, A A
2015-08-01
We present a simple and effective method for measuring urine S-adenosylhomocysteine by capillary electrophoresis without using modifiers. The detection threshold of the method is 0.1 μM S-adenosylhomocysteine, the time of analysis 13 min, reproducibility at physiological concentrations within 4%.